Sample records for dynamic radiographic capability

  1. Development Of A Dynamic Radiographic Capability Using High-Speed Video

    NASA Astrophysics Data System (ADS)

    Bryant, Lawrence E.

    1985-02-01

    High-speed video equipment can be used to optically image up to 2,000 full frames per second or 12,000 partial frames per second. X-ray image intensifiers have historically been used to image radiographic images at 30 frames per second. By combining these two types of equipment, it is possible to perform dynamic x-ray imaging of up to 2,000 full frames per second. The technique has been demonstrated using conventional, industrial x-ray sources such as 150 Kv and 300 Kv constant potential x-ray generators, 2.5 MeV Van de Graaffs, and linear accelerators. A crude form of this high-speed radiographic imaging has been shown to be possible with a cobalt 60 source. Use of a maximum aperture lens makes best use of the available light output from the image intensifier. The x-ray image intensifier input and output fluors decay rapidly enough to allow the high frame rate imaging. Data are presented on the maximum possible video frame rates versus x-ray penetration of various thicknesses of aluminum and steel. Photographs illustrate typical radiographic setups using the high speed imaging method. Video recordings show several demonstrations of this technique with the played-back x-ray images slowed down up to 100 times as compared to the actual event speed. Typical applications include boiling type action of liquids in metal containers, compressor operation with visualization of crankshaft, connecting rod and piston movement and thermal battery operation. An interesting aspect of this technique combines both the optical and x-ray capabilities to observe an object or event with both external and internal details with one camera in a visual mode and the other camera in an x-ray mode. This allows both kinds of video images to appear side by side in a synchronized presentation.

  2. GPU acceleration for digitally reconstructed radiographs using bindless texture objects and CUDA/OpenGL interoperability.

    PubMed

    Abdellah, Marwan; Eldeib, Ayman; Owis, Mohamed I

    2015-01-01

    This paper features an advanced implementation of the X-ray rendering algorithm that harnesses the giant computing power of the current commodity graphics processors to accelerate the generation of high resolution digitally reconstructed radiographs (DRRs). The presented pipeline exploits the latest features of NVIDIA Graphics Processing Unit (GPU) architectures, mainly bindless texture objects and dynamic parallelism. The rendering throughput is substantially improved by exploiting the interoperability mechanisms between CUDA and OpenGL. The benchmarks of our optimized rendering pipeline reflect its capability of generating DRRs with resolutions of 2048(2) and 4096(2) at interactive and semi interactive frame-rates using an NVIDIA GeForce 970 GTX device.

  3. Detecting fiducials affected by trombone delay in ARC and the main laser alignment at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Awwal, Abdul A. S.; Bliss, Erlan S.; Miller Kamm, Victoria; Leach, Richard R.; Roberts, Randy; Rushford, Michael C.; Lowe-Webb, Roger; Wilhelmsen, Karl

    2015-09-01

    Four of the 192 beams of the National Ignition Facility (NIF) are currently being diverted into the Advanced Radiographic Capability (ARC) system to generate a sequence of short (1-50 picoseconds) 1053 nm laser pulses. When focused onto high Z wires in vacuum, these pulses create high energy x-ray pulses capable of penetrating the dense, imploding fusion fuel plasma during ignition scale experiments. The transmitted x-rays imaged with x-ray diagnostics can create movie radiographs that are expected to provide unprecedented insight into the implosion dynamics. The resulting images will serve as a diagnostic for tuning the experimental parameters towards successful fusion reactions. Beam delays introduced into the ARC pulses via independent, free-space optical trombones create the desired x-ray image sequence, or movie. However, these beam delays cause optical distortion of various alignment fiducials viewed by alignment sensors in the NIF and ARC beamlines. This work describes how the position of circular alignment fiducials is estimated in the presence of distortion.

  4. Quantification and visualization of relative local ventilation on dynamic chest radiographs

    NASA Astrophysics Data System (ADS)

    Tanaka, Rie; Sanada, Shigeru; Okazaki, Nobuo; Kobayashi, Takeshi; Nakayama, Kazuya; Matsui, Takeshi; Hayashi, Norio; Matsui, Osamu

    2006-03-01

    Recently-developed dynamic flat-panel detector (FPD) with a large field of view is possible to obtain breathing chest radiographs, which provide respiratory kinetics information. This study was performed to investigate the ability of dynamic chest radiography using FPD to quantify relative ventilation according to respiratory physiology. We also reported the results of primary clinical study and described the possibility of clinical use of our method. Dynamic chest radiographs of 12 subjects involving abnormal subjects during respiration were obtained using a modified FPD system (30 frames in 10 seconds). Imaging was performed in three different positions (standing, and right and left decubitus positions) to change the distribution of local ventilation by changing the lung's own gravity in each area. The distance from the lung apex to the diaphragm (abbr. DLD) was measured by the edge detection technique for use as an index of respiratory phase. We measured pixel values in each lung area and calculated correlation coefficients with DLD. Differences in the pixel values between the maximum inspiratory and expiratory frame were calculated, and the trend of distribution was evaluated by two-way analysis of variance. Pixel value in each lung area was strongly associated with respiratory phase and its time variation and distribution were consistent with known properties in respiratory physiology. Dynamic chest radiography using FPD combined with our computerized methods was capable of quantifying relative amount of ventilation during respiration, and of detecting regional differences in ventilation. In the subjects with emphysema, areas with decreased respiratory changes in pixel value are consisted with the areas with air trapping. This method is expected to be a useful novel diagnostic imaging method for supporting diagnosis and follow-up of pulmonary disease, which presents with abnormalities in local ventilation.

  5. Radiographic visualization of magma dynamics in an erupting volcano.

    PubMed

    Tanaka, Hiroyuki K M; Kusagaya, Taro; Shinohara, Hiroshi

    2014-03-10

    Radiographic imaging of magma dynamics in a volcanic conduit provides detailed information about ascent and descent of magma, the magma flow rate, the conduit diameter and inflation and deflation of magma due to volatile expansion and release. Here we report the first radiographic observation of the ascent and descent of magma along a conduit utilizing atmospheric (cosmic ray) muons (muography) with dynamic radiographic imaging. Time sequential radiographic images show that the top of the magma column ascends right beneath the crater floor through which the eruption column was observed. In addition to the visualization of this magma inflation, we report a sequence of images that show magma descending. We further propose that the monitoring of temporal variations in the gas volume fraction of magma as well as its position in a conduit can be used to support existing eruption prediction procedures.

  6. Radiographic visualization of magma dynamics in an erupting volcano

    PubMed Central

    Tanaka, Hiroyuki K. M.; Kusagaya, Taro; Shinohara, Hiroshi

    2014-01-01

    Radiographic imaging of magma dynamics in a volcanic conduit provides detailed information about ascent and descent of magma, the magma flow rate, the conduit diameter and inflation and deflation of magma due to volatile expansion and release. Here we report the first radiographic observation of the ascent and descent of magma along a conduit utilizing atmospheric (cosmic ray) muons (muography) with dynamic radiographic imaging. Time sequential radiographic images show that the top of the magma column ascends right beneath the crater floor through which the eruption column was observed. In addition to the visualization of this magma inflation, we report a sequence of images that show magma descending. We further propose that the monitoring of temporal variations in the gas volume fraction of magma as well as its position in a conduit can be used to support existing eruption prediction procedures. PMID:24614612

  7. Fabrication and characteristics of experimental radiographic amplifier screens. [image transducers with improved image contrast and resolution

    NASA Technical Reports Server (NTRS)

    Szepesi, Z.

    1978-01-01

    The fabrication process and transfer characteristics for solid state radiographic image transducers (radiographic amplifier screens) are described. These screens are for use in realtime nondestructive evaluation procedures that require large format radiographic images with contrast and resolution capabilities unavailable with conventional fluoroscopic screens. The screens are suitable for in-motion, on-line radiographic inspection by means of closed circuit television. Experimental effort was made to improve image quality and response to low energy (5 kV and up) X-rays.

  8. Development Of A Flash X-Ray Scanner For Stereoradiography And CT

    NASA Astrophysics Data System (ADS)

    Endorf, Robert J.; DiBianca, Frank A.; Fritsch, Daniel S.; Liu, Wen-Ching; Burns, Charles B.

    1989-05-01

    We are developing a flash x-ray scanner for stereoradiography and CT which will be able to produce a stereoradiograph in 30 to 70 ns and a complete CT scan in one microsecond. This type of imaging device will be valuable in studying high speed processes, high acceleration, and traumatic events. We have built a two channel flash x-ray system capable of producing stereo radiographs with stereo angles of from 15 to 165 degrees. The dynamic and static Miff 's for the flash x-ray system were measured and compared with similar MIT's measured for a conventional medical x-ray system. We have written and tested a stereo reconstruction algorithm to determine three dimensional space points from corresponding points in the two stereo images. To demonstrate the ability of the system to image traumatic events, a radiograph was obtained of a bone undergoing a fracture. The effects of accelerations of up to 600 g were examined on radiographs taken of human kidney tissue samples in a rapidly rotating centrifuge. Feasibility studies of CT reconstruction have been performed by making simulated Cr images of various phantoms for larger flash x-ray systems of from 8 to 29 flash x-ray tubes.

  9. ISSLS PRIZE IN BIOENGINEERING SCIENCE 2018: dynamic imaging of degenerative spondylolisthesis reveals mid-range dynamic lumbar instability not evident on static clinical radiographs.

    PubMed

    Dombrowski, Malcolm E; Rynearson, Bryan; LeVasseur, Clarissa; Adgate, Zach; Donaldson, William F; Lee, Joon Y; Aiyangar, Ameet; Anderst, William J

    2018-04-01

    Degenerative spondylolisthesis (DS) in the setting of symptomatic lumbar spinal stenosis is commonly treated with spinal fusion in addition to decompression with laminectomy. However, recent studies have shown similar clinical outcomes after decompression alone, suggesting that a subset of DS patients may not require spinal fusion. Identification of dynamic instability could prove useful for predicting which patients are at higher risk of post-laminectomy destabilization necessitating fusion. The goal of this study was to determine if static clinical radiographs adequately characterize dynamic instability in patients with lumbar degenerative spondylolisthesis (DS) and to compare the rotational and translational kinematics in vivo during continuous dynamic flexion activity in DS versus asymptomatic age-matched controls. Seven patients with symptomatic single level lumbar DS (6 M, 1 F; 66 ± 5.0 years) and seven age-matched asymptomatic controls (5 M, 2 F age 63.9 ± 6.4 years) underwent biplane radiographic imaging during continuous torso flexion. A volumetric model-based tracking system was used to track each vertebra in the radiographic images using subject-specific 3D bone models from high-resolution computed tomography (CT). In vivo continuous dynamic sagittal rotation (flexion/extension) and AP translation (slip) were calculated and compared to clinical measures of intervertebral flexion/extension and AP translation obtained from standard lateral flexion/extension radiographs. Static clinical radiographs underestimate the degree of AP translation seen on dynamic in vivo imaging (1.0 vs 3.1 mm; p = 0.03). DS patients demonstrated three primary motion patterns compared to a single kinematic pattern in asymptomatic controls when analyzing continuous dynamic in vivo imaging. 3/7 (42%) of patients with DS demonstrated aberrant mid-range motion. Continuous in vivo dynamic imaging in DS reveals a spectrum of aberrant motion with significantly greater kinematic heterogeneity than previously realized that is not readily seen on current clinical imaging. Level V data These slides can be retrieved under Electronic Supplementary Material.

  10. Comparison of Mechanical Axis and Dynamic Range Assessed with Weight Bearing Radiographs and Navigation System in Closed Wedge High Tibial Osteotomy

    PubMed Central

    Bae, Dae Kyung; Lee, Jong Whan; Cho, Seong Jin; Song, Sang Jun

    2017-01-01

    Purpose To compare navigation and weight bearing radiographic measurements of mechanical axis (MA) before and after closed wedge high tibial osteotomy (HTO) and to evaluate post-osteotomy changes in MA assessed during application of external varus or valgus force. Materials and Methods Data from 30 consecutive patients (30 knees) who underwent computer-assisted closed-wedge HTO were prospectively analyzed. Pre- and postoperative weight bearing radiographic evaluation of MA was performed. Under navigation guidance, pre- and post-osteotomy MA values were measured in an unloaded position. Any change in the post-osteotomy MA in response to external varus or valgus force, which was named as dynamic range, was evaluated with the navigation system. The navigation and weight bearing radiographic measurements were compared. Results Although there was a positive correlation between navigation and radiographic measurements, the reliability of navigation measurements of coronal alignment was reduced after osteotomy and wedge closing. The mean post-osteotomy MA value measured with the navigation was 3.5°±0.8° valgus in an unloaded position. It was 1.3°±0.8° valgus under varus force and 5.8°±1.1° valgus under valgus force. The average dynamic range was >±2°. Conclusions Potential differences between the postoperative MAs assessed by weight bearing radiographs and the navigation system in unloaded position should be considered during computer-assisted closed wedge HTO. Care should be taken to keep the dynamic range within the permissible range of alignment goal in HTO. PMID:28854769

  11. Improvement of density resolution in short-pulse hard x-ray radiographic imaging using detector stacks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borm, B.; Gärtner, F.; Khaghani, D.

    2016-09-15

    We demonstrate that stacking several imaging plates (IPs) constitutes an easy method to increase hard x-ray detection efficiency. Used to record x-ray radiographic images produced by an intense-laser driven hard x-ray backlighter source, the IP stacks resulted in a significant improvement of the radiograph density resolution. We attribute this to the higher quantum efficiency of the combined detectors, leading to a reduced photon noise. Electron-photon transport simulations of the interaction processes in the detector reproduce the observed contrast improvement. Increasing the detection efficiency to enhance radiographic imaging capabilities is equally effective as increasing the x-ray source yield, e.g., by amore » larger drive laser energy.« less

  12. Investigation of an electronic image enhancer for radiographs

    NASA Technical Reports Server (NTRS)

    Vary, A.

    1972-01-01

    Radiographs of nuclear and aerospace components were studied with a closed-circuit television system to determine the advantages of electronic enhancement in radiographic nondestructive evaluation. The radiographic images were examined on a television monitor under various degrees of magnification and enhancement. The enhancement was accomplished by generating a video signal whose amplitude is proportional to the rate of change of density. Points, lines, edges, and other density variations that are faintly registered in the original image are rendered in sharp relief. Examples of the applications of this mode of enhancement are discussed together with the system's dynamic response and resolution.

  13. Investigation of an electronic image enhancer for radiographs.

    NASA Technical Reports Server (NTRS)

    Vary, A.

    1972-01-01

    Radiographs of nuclear and aerospace components were studied with a closed-circuit television system to determine the advantages of electronic enhancement in radiographic nondestructive evaluation. The radiographic images were examined on a television monitor under various degrees of magnification and enhancement. The enhancement was accomplished by generating a video signal whose amplitude is proportional to the rate of change of density. Points, lines, edges, and other density variations that are faintly registered in the original image are rendered in sharp relief. Examples of the applications of this mode of enhancement are discussed together with the system's dynamic response and resolution.

  14. Quality control procedures for dynamic treatment delivery techniques involving couch motion.

    PubMed

    Yu, Victoria Y; Fahimian, Benjamin P; Xing, Lei; Hristov, Dimitre H

    2014-08-01

    In this study, the authors introduce and demonstrate quality control procedures for evaluating the geometric and dosimetric fidelity of dynamic treatment delivery techniques involving treatment couch motion synchronous with gantry and multileaf collimator (MLC). Tests were designed to evaluate positional accuracy, velocity constancy and accuracy for dynamic couch motion under a realistic weight load. A test evaluating the geometric accuracy of the system in delivering treatments over complex dynamic trajectories was also devised. Custom XML scripts that control the Varian TrueBeam™ STx (Serial #3) axes in Developer Mode were written to implement the delivery sequences for the tests. Delivered dose patterns were captured with radiographic film or the electronic portal imaging device. The couch translational accuracy in dynamic treatment mode was 0.01 cm. Rotational accuracy was within 0.3°, with 0.04 cm displacement of the rotational axis. Dose intensity profiles capturing the velocity constancy and accuracy for translations and rotation exhibited standard deviation and maximum deviations below 3%. For complex delivery involving MLC and couch motions, the overall translational accuracy for reproducing programmed patterns was within 0.06 cm. The authors conclude that in Developer Mode, TrueBeam™ is capable of delivering dynamic treatment delivery techniques involving couch motion with good geometric and dosimetric fidelity.

  15. Computerized method to compensate for breathing body motion in dynamic chest radiographs

    NASA Astrophysics Data System (ADS)

    Matsuda, H.; Tanaka, R.; Sanada, S.

    2017-03-01

    Dynamic chest radiography combined with computer analysis allows quantitative analyses on pulmonary function and rib motion. The accuracy of kinematic analysis is directly linked to diagnostic accuracy, and thus body motion compensation is a major concern. Our purpose in this study was to develop a computerized method to reduce a breathing body motion in dynamic chest radiographs. Dynamic chest radiographs of 56 patients were obtained using a dynamic flat-panel detector. The images were divided into a 1 cm-square and the squares on body counter were used to detect the body motion. Velocity vector was measured using cross-correlation method on the body counter and the body motion was then determined on the basis of the summation of motion vector. The body motion was then compensated by shifting the images based on the measured vector. By using our method, the body motion was accurately detected by the order of a few pixels in clinical cases, mean 82.5% in right and left directions. In addition, our method detected slight body motion which was not able to be identified by human observations. We confirmed our method effectively worked in kinetic analysis of rib motion. The present method would be useful for the reduction of a breathing body motion in dynamic chest radiography.

  16. The 'radiographer-referrer game': image interpretation dynamics in rural practice.

    PubMed

    Squibb, Kathryn; Smith, Anthony; Dalton, Lisa; Bull, Rosalind M

    2016-03-01

    Effective interprofessional communication is intrinsic to safe health care. Despite the identified positive impact of collaborative radiographic interpretation between rural radiographers and referrers, communication difficulties still exist. This article describes the strategies that Australian rural radiographers use for communication of their radiographic opinion to the referring doctor. In a two-phase interpretive doctoral study completed in 2012, data were collected from radiographers working in rural New South Wales, Western Australia and Tasmania using a paper based questionnaire followed by in-depth semistructured interviews. Data were analysed thematically in order to identify, analyse and report the emergent themes. The overarching theme was Patient Advocacy, where in the interest of patient care radiographers took measures to ensure that a referring doctor did not miss radiographic abnormalities. Strong interprofessional relationships enabled direct communication pathways. Interprofessional boundaries shaped by historical hierarchical relationships, together with a lack of confidence and educational preparation for radiographic interpretation result in barriers to direct communication pathways. These barriers prompted radiographers to pursue indirect communication pathways, such as side-stepping and hint and hope. A lack of formal communication pathways and educational preparation for this role has resulted in radiographers playing the radiographer-referrer game to overtly or covertly assist referrers in reaching a radiographic diagnosis. The findings from this study may be used to plan interventions for strengthening interprofessional communication pathways and improve quality of healthcare for patients.

  17. Comparison of pedicle screw-based dynamic stabilization and fusion surgery in the treatment of radiographic adjacent-segment degeneration: a retrospective analysis of single L5-S1 degenerative spondylosis covering 4 years.

    PubMed

    Han, Yu; Sun, Jianguang; Luo, Chenghan; Huang, Shilei; Li, Liren; Ji, Xiang; Duan, Xiaozong; Wang, Zhenqing; Pi, Guofu

    2016-12-01

    OBJECTIVE Pedicle screw-based dynamic spinal stabilization systems (PDSs) were devised to decrease, theoretically, the risk of long-term complications such as adjacent-segment degeneration (ASD) after lumbar fusion surgery. However, to date, there have been few studies that fully proved that a PDS can reduce the risk of ASD. The purpose of this study was to examine whether a PDS can influence the incidence of ASD and to discuss the surgical coping strategy for L5-S1 segmental spondylosis with preexisting L4-5 degeneration with no related symptoms or signs. METHODS This study retrospectively compared 62 cases of L5-S1 segmental spondylosis in patients who underwent posterior lumbar interbody fusion (n = 31) or K-Rod dynamic stabilization (n = 31) with a minimum of 4 years' follow-up. The authors measured the intervertebral heights and spinopelvic parameters on standing lateral radiographs and evaluated preexisting ASD on preoperative MR images using the modified Pfirrmann grading system. Radiographic ASD was evaluated according to the results of radiography during follow-up. RESULTS All 62 patients achieved remission of their neurological symptoms without surgical complications. The Kaplan-Meier curve and Cox proportional-hazards model showed no statistically significant differences between the 2 surgical groups in the incidence of radiographic ASD (p > 0.05). In contrast, the incidence of radiographic ASD was 8.75 times (95% CI 1.955-39.140; p = 0.005) higher in the patients with a preoperative modified Pfirrmann grade higher than 3 than it was in patients with a modified Pfirrmann grade of 3 or lower. In addition, no statistical significance was found for other risk factors such as age, sex, and spinopelvic parameters. CONCLUSIONS Pedicle screw-based dynamic spinal stabilization systems were not found to be superior to posterior lumbar interbody fusion in preventing radiographic ASD (L4-5) during the midterm follow-up. Preexisting ASD with a modified Pfirrmann grade higher than 3 was a risk factor for radiographic ASD. In the treatment of degenerative diseases of the lumbosacral spine, the authors found that both of these methods are feasible. Also, the authors believe that no extra treatment, other than observation, is needed for preexisting degeneration in L4-5 without any clinical symptoms or signs.

  18. Femoral anteversion assessment: Comparison of physical examination, gait analysis, and EOS biplanar radiography.

    PubMed

    Westberry, David E; Wack, Linda I; Davis, Roy B; Hardin, James W

    2018-05-01

    Multiple measurement methods are available to assess transverse plane alignment of the lower extremity. This study was performed to determine the extent of correlation between femoral anteversion assessment using simultaneous biplanar radiographs and three-dimensional modeling (EOS imaging), clinical hip rotation by physical examination, and dynamic hip rotation assessed by gait analysis. Seventy-seven patients with cerebral palsy (GMFCS Level I and II) and 33 neurologically typical children with torsional abnormalities completed a comprehensive gait analysis with same day biplanar anterior-posterior and lateral radiographs and three-dimensional transverse plane assessment of femoral anteversion. Correlations were determined between physical exam of hip rotation, EOS imaging of femoral anteversion, and transverse plane hip kinematics for this retrospective review study. Linear regression analysis revealed a weak relationship between physical examination measures of hip rotation and biplanar radiographic assessment of femoral anteversion. Similarly, poor correlation was found between clinical evaluation of femoral anteversion and motion assessment of dynamic hip rotation. Correlations were better in neurologically typical children with torsional abnormalities compared to children with gait dysfunction secondary to cerebral palsy. Dynamic hip rotation cannot be predicted by physical examination measures of hip range of motion or from three-dimensional assessment of femoral anteversion derived from biplanar radiographs. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. A Workstation for Interactive Display and Quantitative Analysis of 3-D and 4-D Biomedical Images

    PubMed Central

    Robb, R.A.; Heffeman, P.B.; Camp, J.J.; Hanson, D.P.

    1986-01-01

    The capability to extract objective and quantitatively accurate information from 3-D radiographic biomedical images has not kept pace with the capabilities to produce the images themselves. This is rather an ironic paradox, since on the one hand the new 3-D and 4-D imaging capabilities promise significant potential for providing greater specificity and sensitivity (i.e., precise objective discrimination and accurate quantitative measurement of body tissue characteristics and function) in clinical diagnostic and basic investigative imaging procedures than ever possible before, but on the other hand, the momentous advances in computer and associated electronic imaging technology which have made these 3-D imaging capabilities possible have not been concomitantly developed for full exploitation of these capabilities. Therefore, we have developed a powerful new microcomputer-based system which permits detailed investigations and evaluation of 3-D and 4-D (dynamic 3-D) biomedical images. The system comprises a special workstation to which all the information in a large 3-D image data base is accessible for rapid display, manipulation, and measurement. The system provides important capabilities for simultaneously representing and analyzing both structural and functional data and their relationships in various organs of the body. This paper provides a detailed description of this system, as well as some of the rationale, background, theoretical concepts, and practical considerations related to system implementation. ImagesFigure 5Figure 7Figure 8Figure 9Figure 10Figure 11Figure 12Figure 13Figure 14Figure 15Figure 16

  20. Correlation between static radiographic measurements and intersegmental angular measurements during gait using a multisegment foot model.

    PubMed

    Lee, Dong Yeon; Seo, Sang Gyo; Kim, Eo Jin; Kim, Sung Ju; Lee, Kyoung Min; Farber, Daniel C; Chung, Chin Youb; Choi, In Ho

    2015-01-01

    Radiographic examination is a widely used evaluation method in the orthopedic clinic. However, conventional radiography alone does not reflect the dynamic changes between foot and ankle segments during gait. Multiple 3-dimensional multisegment foot models (3D MFMs) have been introduced to evaluate intersegmental motion of the foot. In this study, we evaluated the correlation between static radiographic indices and intersegmental foot motion indices. One hundred twenty-five females were tested. Static radiographs of full-leg and anteroposterior (AP) and lateral foot views were performed. For hindfoot evaluation, we measured the AP tibiotalar angle (TiTA), talar tilt (TT), calcaneal pitch, lateral tibiocalcaneal angle, and lateral talcocalcaneal angle. For the midfoot segment, naviculocuboid overlap and talonavicular coverage angle were calculated. AP and lateral talo-first metatarsal angles and metatarsal stacking angle (MSA) were measured to assess the forefoot. Hallux valgus angle (HVA) and hallux interphalangeal angle were measured. In gait analysis by 3D MFM, intersegmental angle (ISA) measurements of each segment (hallux, forefoot, hindfoot, arch) were recorded. ISAs at midstance phase were most highly correlated with radiography. Significant correlations were observed between ISA measurements using MFM and static radiographic measurements in the same segment. In the hindfoot, coronal plane ISA was correlated with AP TiTA (P < .001) and TT (P = .018). In the hallux, HVA was strongly correlated with transverse ISA of the hallux (P < .001). The segmental foot motion indices at midstance phase during gait measured by 3D MFM gait analysis were correlated with the conventional radiographic indices. The observed correlation between MFM measurements at midstance phase during gait and static radiographic measurements supports the fundamental basis for the use of MFM in analysis of dynamic motion of foot segment during gait. © The Author(s) 2014.

  1. The relationship between pain and dynamic knee joint loading in knee osteoarthritis varies with radiographic disease severity. A cross sectional study.

    PubMed

    Henriksen, Marius; Aaboe, Jens; Bliddal, Henning

    2012-08-01

    In a cross sectional study, we investigated the relationships between knee pain and mechanical loading across the knee, as indicated by the external knee adduction moment (KAM) during walking in patients with symptomatic knee OA who were distinguished by different radiographic disease severities. Data from 137 symptomatic medial knee OA patients were used. Based on Kellgren/Lawrence (K/L) grading, the patients were divided into radiographically less severe (K/L ≤ 2, n=68) or severe (K/L>2, n=69) medial knee OA. Overall knee pain was rated on a 10 cm visual analog scale, and peak KAM and KAM impulses were obtained from gait analyses. Mixed linear regression analyses were performed with KAM variables as the outcome, and pain and disease severity as independent variables, adjusting for age, gender, and walking speed. In adjusted analyses, less severe patients demonstrated negative relationships between pain intensities and dynamic loading. The severe patient group showed no relationship between pain intensity and peak KAM, and a positive relationship between pain intensity and KAM impulse. In radiographically less severe knee OA, the negative relationships between pain intensity and dynamic knee joint loading indicate a natural reaction to pain, which will limit the stress on the joint. In contrast, either absent or positive relationships between pain and dynamic loading in severe OA may lead to overuse and accelerated disease progression. These findings may have a large potential interest for strategies of treatment in knee OA. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Variability of single-leg versus double-leg stance radiographs in the varus knee.

    PubMed

    Chen, Andrew; Rich, Valerie; Bain, Elizabeth; Sterett, William I

    2009-07-01

    We evaluated measured radiographic parameter variability between single-leg stance (SLS) and double-leg stance (DLS) radiographs in patients with varus knee malalignment, indicated for high tibial osteotomy. Fifty-three consecutive knees (mean, 49 years; range, 18-79 years) were evaluated for varus thrust. SLS and DLS radiographs were obtained. A single blinded observer measured mechanical axis angles and weight-bearing line (WBL) deviation using a goniometer. Mechanical axis angles averaged 9.1 degrees (DLS) and 11.3 degrees (SLS). SLS radiographs averaged 9% greater WBL medialization than did DLS. Medial opening averaged 16.4 mm (DLS) and 18.8 mm (SLS). DLS and SLS radiographs showed no significant differences in patients without varus thrust. Patients with varus thrust demonstrated differences in mechanical axis angles (DLS, 9.4 degrees; SLS, 12.2 degrees), WBL deviation (12.1% less), medialization (DLS), and medial opening necessary for correction (DLS, 16.6 mm; SLS, 20.3 mm). In varus thrust, SLS radiographs more closely replicate dynamic knee malalignment, possibly providing more accurate measurements of angular deformity.

  3. Evaluation of Deblur Methods for Radiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wood, William M.

    2014-03-31

    Radiography is used as a primary diagnostic for dynamic experiments, providing timeresolved radiographic measurements of areal mass density along a line of sight through the experiment. It is well known that the finite spot extent of the radiographic source, as well as scattering, are sources of blurring of the radiographic images. This blurring interferes with quantitative measurement of the areal mass density. In order to improve the quantitative utility of this diagnostic, it is necessary to deblur or “restore” the radiographs to recover the “true” areal mass density from a radiographic transmission measurement. Towards this end, I am evaluating threemore » separate methods currently in use for deblurring radiographs. I begin by briefly describing the problems associated with image restoration, and outlining the three methods. Next, I illustrate how blurring affects the quantitative measurements using radiographs. I then present the results of the various deblur methods, evaluating each according to several criteria. After I have summarized the results of the evaluation, I give a detailed account of how the restoration process is actually implemented.« less

  4. Usefulness of prone cross-table lateral radiographs in vertebral compression fractures.

    PubMed

    Cho, Jae Hwan; Shin, Sang Ik; Lee, Jae Hyup; Yeom, Jin Sup; Chang, Bong-Soon; Lee, Choon-Ki

    2013-09-01

    Dynamic radiographs are recommended to investigate non-healing evidence such as the dynamic mobility or intravertebral clefts in osteoporotic vertebral compression fractures (VCFs). However, it is difficult to examine standing flexion and extension lateral radiographs due to severe pain. The use of prone cross-table lateral radiographs (PrLRs) as a diagnostic tool has never been proposed to our knowledge. The purpose of this study is to clarify the usefulness of PrLRs in diagnosis and treatment of VCFs. We reviewed 62 VCF patients examined with PrLRs between January 1, 2008 and June 30, 2011. To compare the degree of pain provoked between standing extension lateral radiographs (StLRs) and PrLRs, numeric rating scale (NRS) scores were assessed and compared by a paired t-test. Vertebroplasty was done for 40 patients and kyphoplasty was done for 9 patients with routine manners. To assess the degree of postural reduction, vertebral wedge angles (VWA) and vertebral height ratios (VHR) were calculated by using preoperative StLRs, PrLRs, and postoperative lateral radiographs. Two variables derived from changes in VWA and VHR between preoperative and postoperative radiographs were compared by a paired t-test. The average NRS scores were 6.23 ± 1.67 in StLRs and 5.18 ± 1.47 in PrLRs. The degree of pain provocation was lower in using PrLRs than StLRs (p < 0.001). The average changes of VWA between preoperative and postoperative status were 5.24° ± 6.16° with PrLRs and 3.46° ± 3.47° with StLRs. The average changes of VHR were 0.248 ± 0.178 with PrLRs and 0.148 ± 0.161 with StLRs. The comparisons by two variables showed significant differences for both parameters (p = 0.021 and p < 0.001, respectively). The postoperative radiological status was reflected more precisely when using PrLRs than StLRs. In comparison with StLR, the PrLR was more accurate in predicting the degree of restoration of postoperative vertebral heights and wedge angles, and provoked less pain during examination. The PrLR could be a useful diagnostic tool to detect intravertebral cleft or intravertebral dynamic instability.

  5. Late post-treatment radiographic changes 3 years following chemoradiation for glioma: the importance of histopathology.

    PubMed

    Galante, Joao R; Rodriguez, Fausto; Grossman, Stuart A; Strowd, Roy E

    2017-07-18

    Treatment-related changes can mimic brain tumor progression both clinically and radiographically. Distinguishing these two entities represents a major challenge in neuro-oncology. No single imaging modality is capable of reliably achieving such distinction. While histopathology remains the gold standard, definitive pathological criteria are also lacking which can further complicate such cases. We report a patient with high-grade glioma who, after initially presenting with histopathologically confirmed pseudoprogression 10 months following treatment, re-presented 3 years following concurrent chemoradiation with clinical and radiographic changes that were most consistent with progressive disease but for which histopathology revealed treatment effects without active glioma. This case highlights the potential late onset of treatment-related changes and underscores the importance of histopathologic assessment even years following initial therapy.

  6. Time-series analysis of lung texture on bone-suppressed dynamic chest radiograph for the evaluation of pulmonary function: a preliminary study

    NASA Astrophysics Data System (ADS)

    Tanaka, Rie; Matsuda, Hiroaki; Sanada, Shigeru

    2017-03-01

    The density of lung tissue changes as demonstrated on imagery is dependent on the relative increases and decreases in the volume of air and lung vessels per unit volume of lung. Therefore, a time-series analysis of lung texture can be used to evaluate relative pulmonary function. This study was performed to assess a time-series analysis of lung texture on dynamic chest radiographs during respiration, and to demonstrate its usefulness in the diagnosis of pulmonary impairments. Sequential chest radiographs of 30 patients were obtained using a dynamic flat-panel detector (FPD; 100 kV, 0.2 mAs/pulse, 15 frames/s, SID = 2.0 m; Prototype, Konica Minolta). Imaging was performed during respiration, and 210 images were obtained over 14 seconds. Commercial bone suppression image-processing software (Clear Read Bone Suppression; Riverain Technologies, Miamisburg, Ohio, USA) was applied to the sequential chest radiographs to create corresponding bone suppression images. Average pixel values, standard deviation (SD), kurtosis, and skewness were calculated based on a density histogram analysis in lung regions. Regions of interest (ROIs) were manually located in the lungs, and the same ROIs were traced by the template matching technique during respiration. Average pixel value effectively differentiated regions with ventilatory defects and normal lung tissue. The average pixel values in normal areas changed dynamically in synchronization with the respiratory phase, whereas those in regions of ventilatory defects indicated reduced variations in pixel value. There were no significant differences between ventilatory defects and normal lung tissue in the other parameters. We confirmed that time-series analysis of lung texture was useful for the evaluation of pulmonary function in dynamic chest radiography during respiration. Pulmonary impairments were detected as reduced changes in pixel value. This technique is a simple, cost-effective diagnostic tool for the evaluation of regional pulmonary function.

  7. Evaluation of the usefulness of color digital summation radiography in temporally sequential digital radiographs: a phantom study.

    PubMed

    Ogata, Yuji; Naito, Hiroaki; Tomiyama, Noriyuki; Hamada, Seiki; Kozuka, Takenori; Koyama, Mitsuhiro; Tsubamoto, Mitusko; Murai, Sachiko; Ueguchi, Takashi; Matsumoto, Mitsuhiro; Tamura, Shinichi; Nakamura, Hironobu; Johkoh, Takeshi

    2006-04-01

    The purpose of this study was to assess the usefulness of color digital summation radiography (CDSR) for detection of nodules on chest radiographs by observers with different levels of experience. A total of 30 radiographs of chest phantoms with abnormalities and 30 normal ones were arranged at random. Set A was conventional radiographs only. Set B consisted of both conventional radiographs and CDSR images, which were colored with magenta. Five chest radiologists and five residents evaluated both image sets on a TFT monitor. The observers were asked to rate each image set using a continuous rating scale. The reading time for each set was also recorded. In set A, the performance of chest radiologists was significantly superior to that of the residents (P < 0.05). However, in set B, there was no significant difference in the performance of the chest radiologists and the residents. In both observer groups, the mean reading time per case in set B was significantly shorter than that in set A (P < 0.01). By using CDSR, the detection capability of observers with little experience improves and is comparable to that of experienced observers. Moreover, the reading time becomes much shorter using CDSR.

  8. Effects of Tamoxifen and oestrogen on histology and radiographic density in high and low mammographic density human breast tissues maintained in murine tissue engineering chambers.

    PubMed

    Chew, G L; Huo, C W; Huang, D; Blick, T; Hill, P; Cawson, J; Frazer, H; Southey, M C; Hopper, J L; Britt, K; Henderson, M A; Haviv, I; Thompson, E W

    2014-11-01

    Mammographic density (MD) is a strong risk factor for breast cancer. It is altered by exogenous endocrine treatments, including hormone replacement therapy and Tamoxifen. Such agents also modify breast cancer (BC) risk. However, the biomolecular basis of how systemic endocrine therapy modifies MD and MD-associated BC risk is poorly understood. This study aims to determine whether our xenograft biochamber model can be used to study the effectiveness of therapies aimed at modulating MD, by examine the effects of Tamoxifen and oestrogen on histologic and radiographic changes in high and low MD tissues maintained within the biochamber model. High and low MD human tissues were precisely sampled under radiographic guidance from prophylactic mastectomy fresh specimens of high-risk women, then inserted into separate vascularized murine biochambers. The murine hosts were concurrently implanted with Tamoxifen, oestrogen or placebo pellets, and the high and low MD biochamber tissues maintained in the murine host environment for 3 months, before the high and low MD biochamber tissues were harvested for histologic and radiographic analyses. The radiographic density of high MD tissue maintained in murine biochambers was decreased in Tamoxifen-treated mice compared to oestrogen-treated mice (p = 0.02). Tamoxifen treatment of high MD tissue in SCID mice led to a decrease in stromal (p = 0.009), and an increase in adipose (p = 0.023) percent areas, compared to placebo-treated mice. No histologic or radiographic differences were observed in low MD biochamber tissue with any treatment. High MD biochamber tissues maintained in mice implanted with Tamoxifen, oestrogen or placebo pellets had dynamic and measurable histologic compositional and radiographic changes. This further validates the dynamic nature of the MD xenograft model, and suggests the biochamber model may be useful for assessing the underlying molecular pathways of Tamoxifen-reduced MD, and in testing of other pharmacologic interventions in a preclinical model of high MD.

  9. Accurate Identification of Fatty Liver Disease in Data Warehouse Utilizing Natural Language Processing.

    PubMed

    Redman, Joseph S; Natarajan, Yamini; Hou, Jason K; Wang, Jingqi; Hanif, Muzammil; Feng, Hua; Kramer, Jennifer R; Desiderio, Roxanne; Xu, Hua; El-Serag, Hashem B; Kanwal, Fasiha

    2017-10-01

    Natural language processing is a powerful technique of machine learning capable of maximizing data extraction from complex electronic medical records. We utilized this technique to develop algorithms capable of "reading" full-text radiology reports to accurately identify the presence of fatty liver disease. Abdominal ultrasound, computerized tomography, and magnetic resonance imaging reports were retrieved from the Veterans Affairs Corporate Data Warehouse from a random national sample of 652 patients. Radiographic fatty liver disease was determined by manual review by two physicians and verified with an expert radiologist. A split validation method was utilized for algorithm development. For all three imaging modalities, the algorithms could identify fatty liver disease with >90% recall and precision, with F-measures >90%. These algorithms could be used to rapidly screen patient records to establish a large cohort to facilitate epidemiological and clinical studies and examine the clinic course and outcomes of patients with radiographic hepatic steatosis.

  10. Radiographic evaluation of the ankle syndesmosis.

    PubMed

    Croft, Stephen; Furey, Andrew; Stone, Craig; Moores, Carl; Wilson, Robert

    2015-02-01

    Radiographic measurements to document ankle anatomy have been suggested in recent literature to be inadequate. Focus has been put on stress views and computed tomography; however, there are also issues with these modalities. An orthogonal view that could be used both statically and dynamically could help determine syndesmotic stability. The purpose of this study was to determine a parameter on a normal lateral ankle radiograph that will increase the reliability of standard radiography in diagnosing syndesmotic integrity. Three orthopedic surgeons reviewed 80 lateral ankle radiographs. Thirty of those radiographs were reviewed on a second occasion. Rotation of the radiographs was determined by evaluating the overlap of the talar dome. Four radiographic parameters were measured 1 cm above the tibial plafond: fibular width, tibial width, and anterior and posterior tibiofibular intervals. Seventy-two radiographs were determined by consensus to be adequate. Means and ratios were documented to determine the relationship of the fibula to the tibia. Interrater reliability ranged from moderate to near-perfect, and the intrarater reliability was documented for each ratio. The anterior tibiofibular ratio was shown to be strong to near-perfect. It demonstrates that 40% of the tibia should be seen anterior to the fibula at 1cm above the tibial plafond. The anterior tibiofibular ratio provides an orthogonal measure for the syndesmosis that, in conjunction with those parameters previously documented, could clinically and economically improve the diagnosis of syndesmotic disruptions.

  11. AXIS: an instrument for imaging Compton radiographs using the Advanced Radiography Capability on the NIF.

    PubMed

    Hall, G N; Izumi, N; Tommasini, R; Carpenter, A C; Palmer, N E; Zacharias, R; Felker, B; Holder, J P; Allen, F V; Bell, P M; Bradley, D; Montesanti, R; Landen, O L

    2014-11-01

    Compton radiography is an important diagnostic for Inertial Confinement Fusion (ICF), as it provides a means to measure the density and asymmetries of the DT fuel in an ICF capsule near the time of peak compression. The AXIS instrument (ARC (Advanced Radiography Capability) X-ray Imaging System) is a gated detector in development for the National Ignition Facility (NIF), and will initially be capable of recording two Compton radiographs during a single NIF shot. The principal reason for the development of AXIS is the requirement for significantly improved detection quantum efficiency (DQE) at high x-ray energies. AXIS will be the detector for Compton radiography driven by the ARC laser, which will be used to produce Bremsstrahlung X-ray backlighter sources over the range of 50 keV-200 keV for this purpose. It is expected that AXIS will be capable of recording these high-energy x-rays with a DQE several times greater than other X-ray cameras at NIF, as well as providing a much larger field of view of the imploded capsule. AXIS will therefore provide an image with larger signal-to-noise that will allow the density and distribution of the compressed DT fuel to be measured with significantly greater accuracy as ICF experiments are tuned for ignition.

  12. Method of identifying defective particle coatings

    DOEpatents

    Cohen, Mark E.; Whiting, Carlton D.

    1986-01-01

    A method for identifying coated particles having defective coatings desig to retain therewithin a build-up of gaseous materials including: (a) Pulling a vacuum on the particles; (b) Backfilling the particles at atmospheric pressure with a liquid capable of wetting the exterior surface of the coated particles, said liquid being a compound which includes an element having an atomic number higher than the highest atomic number of any element in the composition which forms the exterior surface of the particle coating; (c) Drying the particles; and (d) Radiographing the particles. By television monitoring, examination of the radiographs is substantially enhanced.

  13. Morphometric Comparison of Clavicle Outlines from 3D Bone Scans and 2D Chest Radiographs: A Short-listing Tool to Assist Radiographic Identification of Human Skeletons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stephan, Carl N.; Amidan, Brett G.; Trease, Harold E.

    This paper describes a computerized clavicle identification system, primarily designed to resolve the identities of unaccounted for US soldiers who fought in the Korean War. Elliptical Fourier analysis is used to quantify the clavicle outline shape from skeletons and postero-anterior antemortem chest radiographs to rank individuals in terms of metric distance. Similar to leading fingerprint identification systems, shortlists of the top matching candidates are extracted for subsequent human visual assessment. Two independent tests of the computerized system using 17 field-recovered skeletons and 409 chest radiographs demonstrate that true positive matches are captured within the top 5% of the sample 75%more » of the time. These results are outstanding given the eroded state of some field-recovered skeletons and the faintness of the 1950’s photoflurographs. These methods enhance the capability to resolve several hundred cold cases for which little circumstantial information exists and current DNA and dental record technologies cannot be applied.« less

  14. Higher Improvement in Patient-Reported Outcomes Can Be Achieved After Transforaminal Lumbar Interbody Fusion for Clinical and Radiographic Degenerative Spondylolisthesis Classification Type D Degenerative Lumbar Spondylolisthesis.

    PubMed

    Chen, Xi; Xu, Liang; Qiu, Yong; Chen, Zhong-Hui; Zhou, Qing-Shuang; Li, Song; Sun, Xu

    2018-06-01

    Clinical and radiographic degenerative spondylolisthesis (CARDS) classification defines a distinct subset of patients with kyphotic angulation at the involved segment (type D). Research using CARDS classification to investigate motion characteristics at involved segments or patient-related outcomes (PROs) following surgical intervention is sparse. We investigated the relationship between CARDS type D spondylolisthesis and dynamic instability and PROs in type D versus non-type D spondylolisthesis. We reviewed consecutive patients who received transforaminal lumbar interbody fusion for L4-5 spondylolisthesis between 2009 and 2015. Patients were assigned into type D and non-type D groups. Translational motion was determined by upright lumbar lateral radiography with supine sagittal magnetic resonance imaging or flexion and extension radiography. Demographics, radiographic parameters, and PROs were evaluated. Type D and non-type D groups comprised 34 and 163 patients, respectively. Compared with non-type D, type D group was characterized by lordotic angulation loss and higher degree of olisthesis on upright radiographs and demonstrated higher translational motion on upright lumbar lateral radiography with supine sagittal magnetic resonance imaging analysis. After surgery, mean reduction rate was significantly higher in type D group; type D had less slippage, but differences in slip angle and disc height were not significant. Preoperative Oswestry Disability Index and visual analog scale for back pain scores were higher in type D group. Type D spondylolisthesis and dynamic instability were associated with achieving minimal clinically important differences in PROs. CARDS type D spondylolisthesis is a distinct subset associated with dynamic instability and worse PROs. Higher improvement in PROs can be achieved in CARDS type D spondylolisthesis after surgery. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Obese patients and radiography literature: what do we know about a big issue?

    PubMed Central

    Le, Nhat Tan Thanh; Robinson, John; Lewis, Sarah J

    2015-01-01

    Obesity is a global health issue with obese patients requiring specialised diagnosis, treatment and care through the health service. The practical and social difficulties associated with medical imaging of obese patients are an increasingly common problem and it is currently unknown how student and qualified radiographers perceive and respond to these challenges. By better understanding challenges presented in providing quality imaging and care of imaging obese patients, education for both qualified and student radiographers can be enhanced. Radiographers are heavily reliant on visual and tactile senses to locate the position of anatomical structures for diagnostic imaging and determine radiation exposure through a delicate consideration of dose, image quality and anatomical attenuation. However, obese patients require modifications to routine radiographic practice in terms of movement/assisted positioning, equipment capabilities to take increased weight or coverage. These patients may also be subject to compromised radiological diagnosis through poor visualisation of structures. In this paper, the professional and educational literature was narratively reviewed to assess gaps in the evidence base related to the skill and care knowledge for obese patients. Literature was sourced relating to discrete radiographic considerations such as the technical factors of imaging obese patients, exposure and the impact of obesity on imaging departments’ service provisions. The recent literature (post-2000 to coincide with the sharp increase in global obesity) on the perceptions of health professionals and student health practitioners has also been explored because there are no specific radiographer studies to report. By understanding the research in similar fields, we may identify what common attitudes qualified and student radiographer's hold and what challenges, technical and care related, can be prepared for. PMID:26229678

  16. Obese patients and radiography literature: what do we know about a big issue?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le, Nhat Tan Thanh; Robinson, John; Lewis, Sarah J, E-mail: sarah.lewis@sydney.edu.au

    Obesity is a global health issue with obese patients requiring specialised diagnosis, treatment and care through the health service. The practical and social difficulties associated with medical imaging of obese patients are an increasingly common problem and it is currently unknown how student and qualified radiographers perceive and respond to these challenges. By better understanding challenges presented in providing quality imaging and care of imaging obese patients, education for both qualified and student radiographers can be enhanced. Radiographers are heavily reliant on visual and tactile senses to locate the position of anatomical structures for diagnostic imaging and determine radiation exposuremore » through a delicate consideration of dose, image quality and anatomical attenuation. However, obese patients require modifications to routine radiographic practice in terms of movement/assisted positioning, equipment capabilities to take increased weight or coverage. These patients may also be subject to compromised radiological diagnosis through poor visualisation of structures. In this paper, the professional and educational literature was narratively reviewed to assess gaps in the evidence base related to the skill and care knowledge for obese patients. Literature was sourced relating to discrete radiographic considerations such as the technical factors of imaging obese patients, exposure and the impact of obesity on imaging departments’ service provisions. The recent literature (post-2000 to coincide with the sharp increase in global obesity) on the perceptions of health professionals and student health practitioners has also been explored because there are no specific radiographer studies to report. By understanding the research in similar fields, we may identify what common attitudes qualified and student radiographer's hold and what challenges, technical and care related, can be prepared for.« less

  17. Evaluation of pulmonary function using breathing chest radiography with a dynamic flat panel detector: primary results in pulmonary diseases.

    PubMed

    Tanaka, Rie; Sanada, Shigeru; Okazaki, Nobuo; Kobayashi, Takeshi; Fujimura, Masaki; Yasui, Masahide; Matsui, Takeshi; Nakayama, Kazuya; Nanbu, Yuko; Matsui, Osamu

    2006-10-01

    Dynamic flat panel detectors (FPD) permit acquisition of distortion-free radiographs with a large field of view and high image quality. The present study was performed to evaluate pulmonary function using breathing chest radiography with a dynamic FPD. We report primary results of a clinical study and computer algorithm for quantifying and visualizing relative local pulmonary airflow. Dynamic chest radiographs of 18 subjects (1 emphysema, 2 asthma, 4 interstitial pneumonia, 1 pulmonary nodule, and 10 normal controls) were obtained during respiration using an FPD system. We measured respiratory changes in distance from the lung apex to the diaphragm (DLD) and pixel values in each lung area. Subsequently, the interframe differences (D-frame) and difference values between maximum inspiratory and expiratory phases (D-max) were calculated. D-max in each lung represents relative vital capacity (VC) and regional D-frames represent pulmonary airflow in each local area. D-frames were superimposed on dynamic chest radiographs in the form of color display (fusion images). The results obtained using our methods were compared with findings on computed tomography (CT) images and pulmonary functional test (PFT), which were examined before inclusion in the study. In normal subjects, the D-frames were distributed symmetrically in both lungs throughout all respiratory phases. However, subjects with pulmonary diseases showed D-frame distribution patterns that differed from the normal pattern. In subjects with air trapping, there were some areas with D-frames near zero indicated as colorless areas on fusion images. These areas also corresponded to the areas showing air trapping on computed tomography images. In asthma, obstructive abnormality was indicated by areas continuously showing D-frame near zero in the upper lung. Patients with interstitial pneumonia commonly showed fusion images with an uneven color distribution accompanied by increased D-frames in the area identified as normal on computed tomography images. Furthermore, measurement of DLD was very effective for evaluating diaphragmatic kinetics. This is a rapid and simple method for evaluation of respiratory kinetics for pulmonary diseases, which can reveal abnormalities in diaphragmatic kinetics and regional lung ventilation. Furthermore, quantification and visualization of respiratory kinetics is useful as an aid in interpreting dynamic chest radiographs.

  18. AXIS: An instrument for imaging Compton radiographs using the Advanced Radiography Capability on the NIF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, G. N., E-mail: hall98@llnl.gov; Izumi, N.; Tommasini, R.

    2014-11-15

    Compton radiography is an important diagnostic for Inertial Confinement Fusion (ICF), as it provides a means to measure the density and asymmetries of the DT fuel in an ICF capsule near the time of peak compression. The AXIS instrument (ARC (Advanced Radiography Capability) X-ray Imaging System) is a gated detector in development for the National Ignition Facility (NIF), and will initially be capable of recording two Compton radiographs during a single NIF shot. The principal reason for the development of AXIS is the requirement for significantly improved detection quantum efficiency (DQE) at high x-ray energies. AXIS will be the detectormore » for Compton radiography driven by the ARC laser, which will be used to produce Bremsstrahlung X-ray backlighter sources over the range of 50 keV–200 keV for this purpose. It is expected that AXIS will be capable of recording these high-energy x-rays with a DQE several times greater than other X-ray cameras at NIF, as well as providing a much larger field of view of the imploded capsule. AXIS will therefore provide an image with larger signal-to-noise that will allow the density and distribution of the compressed DT fuel to be measured with significantly greater accuracy as ICF experiments are tuned for ignition.« less

  19. Positron Radiography of Ignition-Relevant ICF Capsules

    NASA Astrophysics Data System (ADS)

    Williams, Jackson; Chen, Hui; Field, John; Landen, Nino; Strozzi, David

    2017-10-01

    X-ray and neutron radiography are currently used to infer residual ICF shell and fuel asymmetries and areal density non-uniformities near and at peak compression that can impede ignition. Charged particles offer an alternative probe source that, in principle, are capable of radiographing the shell shape and areal density at arbitrary times, even in the presence of large x-ray self-emission. Laser-generated positrons are evaluated as a source to radiograph ICF capsules where current ultraintense laser facilities are capable of producing 2 ×1012 relativistic positrons in a narrow energy bandwidth and short duration. Monte Carlo simulations suggest that both the areal density and shell radius can be reconstructed for ignition-relevant capsules conditions between 0.002-2 g/cm2, and that this technique might be better suited to direct-drive. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344 and funded by the LDRD Program under project tracking code 17-ERD-010.

  20. Leveraging multi-channel x-ray detector technology to improve quality metrics for industrial and security applications

    NASA Astrophysics Data System (ADS)

    Jimenez, Edward S.; Thompson, Kyle R.; Stohn, Adriana; Goodner, Ryan N.

    2017-09-01

    Sandia National Laboratories has recently developed the capability to acquire multi-channel radio- graphs for multiple research and development applications in industry and security. This capability allows for the acquisition of x-ray radiographs or sinogram data to be acquired at up to 300 keV with up to 128 channels per pixel. This work will investigate whether multiple quality metrics for computed tomography can actually benefit from binned projection data compared to traditionally acquired grayscale sinogram data. Features and metrics to be evaluated include the ability to dis- tinguish between two different materials with similar absorption properties, artifact reduction, and signal-to-noise for both raw data and reconstructed volumetric data. The impact of this technology to non-destructive evaluation, national security, and industry is wide-ranging and has to potential to improve upon many inspection methods such as dual-energy methods, material identification, object segmentation, and computer vision on radiographs.

  1. Noninvasive Optoelectronic Assessment of Induced Sagittal Imbalance Using the Vicon System.

    PubMed

    Ould-Slimane, Mourad; Latrobe, Charles; Michelin, Paul; Chastan, Nathalie; Dujardin, Franck; Roussignol, Xavier; Gauthé, Rémi

    2017-06-01

    Spinal diseases often induce gait disorders with multifactorial origins such as lumbar pain, radicular pain, neurologic complications, or spinal deformities. However, radiography does not permit an analysis of spinal dynamics; therefore, sagittal balance dynamics during gait remain largely unexplored. This prospective and controlled pilot study assessed the Vicon system for detecting sagittal spinopelvic imbalance, to determine the correlations between optoelectronic and radiographic parameters. Reversible anterior sagittal imbalance was induced in 24 healthy men using a thoracolumbar corset. Radiographic, optoelectronic, and comparative analyses were conducted. Corset wearing induced significant variations in radiographic parameters indicative of imbalance; the mean C7-tilt and d/D ratio increased by 15° ± 7.4° and 359%, respectively, whereas the mean spinosacral angle decreased by 16.8° ± 8° (all P < 0.001). The Vicon system detected the imbalance; the mean spinal angle increased by 15.4° ± 5.6° (P < 0.01), the mean floor projection of the C7S1 vector (C7'S1') increased by 126.3 ± 51.9 mm (P < 0.001), and the mean C7-T10-S1 angle decreased by 9.8° ± 3° (P < 0.001). Variations in C7'S1' were significantly correlated with d/D ratio (ρ = 0.58; P < 0.05) and C7-tilt (ρ = 0.636; P < 0.05) variations. Corset wearing induced radiographically confirmed anterior sagittal imbalance detected using the Vicon system. Optoelectronic C7'S1' correlated with radiographic C7-tilt and d/D ratio. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Performance evaluation of an improved optical computed tomography polymer gel dosimeter system for 3D dose verification of static and dynamic phantom deliveries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopatiuk-Tirpak, O.; Langen, K. M.; Meeks, S. L.

    2008-09-15

    The performance of a next-generation optical computed tomography scanner (OCTOPUS-5X) is characterized in the context of three-dimensional gel dosimetry. Large-volume (2.2 L), muscle-equivalent, radiation-sensitive polymer gel dosimeters (BANG-3) were used. Improvements in scanner design leading to shorter acquisition times are discussed. The spatial resolution, detectable absorbance range, and reproducibility are assessed. An efficient method for calibrating gel dosimeters using the depth-dose relationship is applied, with photon- and electron-based deliveries yielding equivalent results. A procedure involving a preirradiation scan was used to reduce the edge artifacts in reconstructed images, thereby increasing the useful cross-sectional area of the dosimeter by nearly amore » factor of 2. Dose distributions derived from optical density measurements using the calibration coefficient show good agreement with the treatment planning system simulations and radiographic film measurements. The feasibility of use for motion (four-dimensional) dosimetry is demonstrated on an example comparing dose distributions from static and dynamic delivery of a single-field photon plan. The capability to visualize three-dimensional dose distributions is also illustrated.« less

  3. Potential usefulness of a video printer for producing secondary images from digitized chest radiographs

    NASA Astrophysics Data System (ADS)

    Nishikawa, Robert M.; MacMahon, Heber; Doi, Kunio; Bosworth, Eric

    1991-05-01

    Communication between radiologists and clinicians could be improved if a secondary image (copy of the original image) accompanied the radiologic report. In addition, the number of lost original radiographs could be decreased, since clinicians would have less need to borrow films. The secondary image should be simple and inexpensive to produce, while providing sufficient image quality for verification of the diagnosis. We are investigating the potential usefulness of a video printer for producing copies of radiographs, i.e. images printed on thermal paper. The video printer we examined (Seikosha model VP-3500) can provide 64 shades of gray. It is capable of recording images up to 1,280 pixels by 1,240 lines and can accept any raster-type video signal. The video printer was characterized in terms of its linearity, contrast, latitude, resolution, and noise properties. The quality of video-printer images was also evaluated in an observer study using portable chest radiographs. We found that observers could confirm up to 90 of the reported findings in the thorax using video- printer images, when the original radiographs were of high quality. The number of verified findings was diminished when high spatial resolution was required (e.g. detection of a subtle pneumothorax) or when a low-contrast finding was located in the mediastinal area or below the diaphragm (e.g. nasogastric tubes).

  4. Technical innovation changes standard radiographic protocols in veterinary medicine: is it necessary to obtain two dorsoproximal-palmarodistal oblique views of the equine foot when using computerised radiography systems?

    PubMed

    Whitlock, J; Dixon, J; Sherlock, C; Tucker, R; Bolt, D M; Weller, R

    2016-05-21

    Since the 1950s, veterinary practitioners have included two separate dorsoproximal-palmarodistal oblique (DPr-PaDiO) radiographs as part of a standard series of the equine foot. One image is obtained to visualise the distal phalanx and the other to visualise the navicular bone. However, rapid development of computed radiography and digital radiography and their post-processing capabilities could mean that this practice is no longer required. The aim of this study was to determine differences in perceived image quality between DPr-PaDiO radiographs that were acquired with a computerised radiography system with exposures, centring and collimation recommended for the navicular bone versus images acquired for the distal phalanx but were subsequently manipulated post-acquisition to highlight the navicular bone. Thirty images were presented to four clinicians for quality assessment and graded using a 1-3 scale (1=textbook quality, 2=diagnostic quality, 3=non-diagnostic image). No significant difference in diagnostic quality was found between the original navicular bone images and the manipulated distal phalanx images. This finding suggests that a single DPr-PaDiO image of the distal phalanx is sufficient for an equine foot radiographic series, with appropriate post-processing and manipulation. This change in protocol will result in reduced radiographic study time and decreased patient/personnel radiation exposure. British Veterinary Association.

  5. 46 CFR 197.328 - PVHO-General.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... approved in accordance with § 54.01-18 of this chapter; (ii) Pass the radiographic and other survey tests...; and (iii) Occupants of other separately pressurized compartments of the same PVHO; (6) If designed to... compartment that is— (i) Designed for human occupancy; and (ii) Capable of having the compartment pressure...

  6. 46 CFR 197.328 - PVHO-General.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... approved in accordance with § 54.01-18 of this chapter; (ii) Pass the radiographic and other survey tests...; and (iii) Occupants of other separately pressurized compartments of the same PVHO; (6) If designed to... compartment that is— (i) Designed for human occupancy; and (ii) Capable of having the compartment pressure...

  7. In vivo kinematic analysis of the glenohumeral joint during dynamic full axial rotation and scapular plane full abduction in healthy shoulders.

    PubMed

    Kozono, Naoya; Okada, Takamitsu; Takeuchi, Naohide; Hamai, Satoshi; Higaki, Hidehiko; Ikebe, Satoru; Shimoto, Takeshi; Miake, Go; Nakanishi, Yoshitaka; Iwamoto, Yukihide

    2017-07-01

    The purpose of this study was to evaluate the kinematics of healthy shoulders during dynamic full axial rotation and scapular plane full abduction using three-dimensional (3D)-to-two-dimensional (2D) model-to-image registration techniques. Dynamic glenohumeral kinematics during axial rotation and scapular plane abduction were analysed in 10 healthy participants. Continuous radiographic images of axial rotation and scapular plane abduction were taken using a flat panel radiographic detector. The participants received a computed tomography scan to generate virtual digitally reconstructed radiographs. The density-based digitally reconstructed radiographs were then compared with the serial radiographic images acquired using image correlations. These 3D-to-2D model-to-image registration techniques determined the 3D positions and orientations of the humerus and scapula during dynamic full axial rotation and scapular plane full abduction. The humeral head centre translated an average of 2.5 ± 3.1 mm posteriorly, and 1.4 ± 1.0 mm superiorly in the early phase, then an average of 2.0 ± 0.8 mm inferiorly in the late phase during external rotation motion. The glenohumeral external rotation angle had a significant effect on the anterior/posterior (A/P) and superior/inferior (S/I) translation of the humeral head centre (both p < 0.05). 33.6 ± 15.6° of glenohumeral external rotation occurred during scapular plane abduction. The humeral head centre translated an average of 0.6 ± 0.9 mm superiorly in the early phase, then 1.7 ± 2.6 mm inferiorly in the late phase, and translated an average of 0.4 ± 0.5 mm medially in the early phase, then 1.6 ± 1.0 mm laterally in the late phase during scapular plane abduction. The humeral abduction angle had a significant effect on the S/I and lateral/medial (L/M) translation of the humeral head centre (both p < 0.05). This study investigated 3D translations of the humerus relative to the scapula: during scapular plane full abduction, the humerus rotated 33.6° externally relative to the scapula, and during external rotation motion in the adducted position, the humeral head centre translated an average of 2.5 mm posteriorly. Kinematic data will provide important insights into evaluating the kinematics of pathological shoulders. For clinical relevance, quantitative assessment of dynamic healthy shoulder kinematics might be a physiological indicator for the assessment of pathological shoulders.

  8. Physical performance and radiographic and clinical vertebral fractures in older men.

    PubMed

    Cawthon, Peggy M; Blackwell, Terri L; Marshall, Lynn M; Fink, Howard A; Kado, Deborah M; Ensrud, Kristine E; Cauley, Jane A; Black, Dennis; Orwoll, Eric S; Cummings, Steven R; Schousboe, John T

    2014-09-01

    In men, the association between poor physical performance and likelihood of incident vertebral fractures is unknown. Using data from the MrOS study (N = 5958), we describe the association between baseline physical performance (walking speed, grip strength, leg power, repeat chair stands, narrow walk [dynamic balance]) and incidence of radiographic and clinical vertebral fractures. At baseline and follow-up an average of 4.6 years later, radiographic vertebral fractures were assessed using semiquantitative (SQ) scoring on lateral thoracic and lumbar radiographs. Logistic regression modeled the association between physical performance and incident radiographic vertebral fractures (change in SQ grade ≥1 from baseline to follow-up). Every 4 months after baseline, participants self-reported fractures; clinical vertebral fractures were confirmed by centralized radiologist review of the baseline study radiograph and community-acquired spine images. Proportional hazards regression modeled the association between physical performance with incident clinical vertebral fractures. Multivariate models were adjusted for age, bone mineral density (BMD, by dual-energy X-ray absorptiometry [DXA]), clinical center, race, smoking, height, weight, history of falls, activity level, and comorbid medical conditions; physical performance was analyzed as quartiles. Of 4332 men with baseline and repeat radiographs, 192 (4.4%) had an incident radiographic vertebral fracture. With the exception of walking speed, poorer performance on repeat chair stands, leg power, narrow walk, and grip strength were each associated in a graded manner with an increased risk of incident radiographic vertebral fracture (p for trend across quartiles <0.001). In addition, men with performance in the worst quartile on three or more exams had an increased risk of radiographic fracture (odds ratio [OR] = 1.81, 95% confidence interval [CI] 1.33-2.45) compared with men with better performance on all exams. Clinical vertebral fracture (n =149 of 5813, 2.6%) was not consistently associated with physical performance. We conclude that poorer physical performance is associated with an increased risk of incident radiographic (but not clinical) vertebral fracture in older men. © 2014 American Society for Bone and Mineral Research.

  9. Short pulse, high resolution, backlighters for point projection high-energy radiography at the National Ignition Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tommasini, R.; Bailey, C.; Bradley, D. K.

    High-resolution, high-energy X-ray backlighters are very active area of research for radiography experiments at the National Ignition Facility (NIF) [Miller et al., Nucl. Fusion 44, S228 (2004)], in particular those aiming at obtaining Compton-scattering produced radiographs from the cold, dense fuel surrounding the hot spot. We report on experiments to generate and characterize point-projection-geometry backlighters using short pulses from the advanced radiographic capability (ARC) [Crane et al., J. Phys. 244, 032003 (2010); Di Nicola et al., Proc. SPIE 2015, 93450I-12], at the NIF, focused on Au micro-wires. We show the first hard X-ray radiographs, at photon energies exceeding 60 keV,more » of static objects obtained with 30 ps-long ARC laser pulses, and the measurements of strength of the X-ray emission, the pulse duration and the source size of the Au micro-wire backlighters. For the latter, a novel technique has been developed and successfully applied.« less

  10. Wavelet analysis methods for radiography of multidimensional growth of planar mixing layers

    DOE PAGES

    Merritt, Elizabeth Catherine; Doss, Forrest William

    2016-07-06

    The counter-propagating shear campaign is examining instability growth and its transition to turbulence in the high-energy-density physics regime using a laser-driven counter-propagating flow platform. In these experiments, we observe consistent complex break-up of and structure growth in a tracer layer placed at the shear flow interface during the instability growth phase. We present a wavelet-transform based analysis technique capable of characterizing the scale- and directionality-resolved average intensity perturbations in static radiographs of the experiment. This technique uses the complete spatial information available in each radiograph to describe the structure evolution. We designed this analysis technique to generate a two-dimensional powermore » spectrum for each radiograph from which we can recover information about structure widths, amplitudes, and orientations. Lastly, the evolution of the distribution of power in the spectra for an experimental series is a potential metric for quantifying the structure size evolution as well as a system’s evolution towards isotropy.« less

  11. Short pulse, high resolution, backlighters for point projection high-energy radiography at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Tommasini, R.; Bailey, C.; Bradley, D. K.; Bowers, M.; Chen, H.; Di Nicola, J. M.; Di Nicola, P.; Gururangan, G.; Hall, G. N.; Hardy, C. M.; Hargrove, D.; Hermann, M.; Hohenberger, M.; Holder, J. P.; Hsing, W.; Izumi, N.; Kalantar, D.; Khan, S.; Kroll, J.; Landen, O. L.; Lawson, J.; Martinez, D.; Masters, N.; Nafziger, J. R.; Nagel, S. R.; Nikroo, A.; Okui, J.; Palmer, D.; Sigurdsson, R.; Vonhof, S.; Wallace, R. J.; Zobrist, T.

    2017-05-01

    High-resolution, high-energy X-ray backlighters are very active area of research for radiography experiments at the National Ignition Facility (NIF) [Miller et al., Nucl. Fusion 44, S228 (2004)], in particular those aiming at obtaining Compton-scattering produced radiographs from the cold, dense fuel surrounding the hot spot. We report on experiments to generate and characterize point-projection-geometry backlighters using short pulses from the advanced radiographic capability (ARC) [Crane et al., J. Phys. 244, 032003 (2010); Di Nicola et al., Proc. SPIE 2015, 93450I-12], at the NIF, focused on Au micro-wires. We show the first hard X-ray radiographs, at photon energies exceeding 60 keV, of static objects obtained with 30 ps-long ARC laser pulses, and the measurements of strength of the X-ray emission, the pulse duration and the source size of the Au micro-wire backlighters. For the latter, a novel technique has been developed and successfully applied.

  12. Short pulse, high resolution, backlighters for point projection high-energy radiography at the National Ignition Facility

    DOE PAGES

    Tommasini, R.; Bailey, C.; Bradley, D. K.; ...

    2017-05-09

    High-resolution, high-energy X-ray backlighters are very active area of research for radiography experiments at the National Ignition Facility (NIF) [Miller et al., Nucl. Fusion 44, S228 (2004)], in particular those aiming at obtaining Compton-scattering produced radiographs from the cold, dense fuel surrounding the hot spot. We report on experiments to generate and characterize point-projection-geometry backlighters using short pulses from the advanced radiographic capability (ARC) [Crane et al., J. Phys. 244, 032003 (2010); Di Nicola et al., Proc. SPIE 2015, 93450I-12], at the NIF, focused on Au micro-wires. We show the first hard X-ray radiographs, at photon energies exceeding 60 keV,more » of static objects obtained with 30 ps-long ARC laser pulses, and the measurements of strength of the X-ray emission, the pulse duration and the source size of the Au micro-wire backlighters. For the latter, a novel technique has been developed and successfully applied.« less

  13. Near-Infrared Imaging for Detecting Caries and Structural Deformities in Teeth

    PubMed Central

    Angelino, Keith; Edlund, David A.

    2017-01-01

    2-D radiographs, while commonly used for evaluating sub-surface hard structures of teeth, have low sensitivity for early caries lesions, particularly those on tooth occlusal surfaces. Radiographs are also frequently refused by patients over safety concerns. Translucency of teeth in the near-infrared (NIR) range offers a non-ionizing and safe approach to detect dental caries. We report the construction of an NIR (850 nm) LED imaging system, comprised of an NIR source and an intraoral camera for rapid dental evaluations. The NIR system was used to image teeth of ten consenting human subjects and successfully detected secondary, amalgam–occluded and early caries lesions without supplementary image processing. The camera-wand system was also capable of revealing demineralized areas, deep and superficial cracks, and other clinical features of teeth usually visualized by X-rays. The NIR system’s clinical utility, simplistic design, low cost, and user friendliness make it an effective dental caries screening technology in conjunction or in place of radiographs. PMID:28507826

  14. Near-Infrared Imaging for Detecting Caries and Structural Deformities in Teeth.

    PubMed

    Angelino, Keith; Edlund, David A; Shah, Pratik

    2017-01-01

    2-D radiographs, while commonly used for evaluating sub-surface hard structures of teeth, have low sensitivity for early caries lesions, particularly those on tooth occlusal surfaces. Radiographs are also frequently refused by patients over safety concerns. Translucency of teeth in the near-infrared (NIR) range offers a non-ionizing and safe approach to detect dental caries. We report the construction of an NIR (850 nm) LED imaging system, comprised of an NIR source and an intraoral camera for rapid dental evaluations. The NIR system was used to image teeth of ten consenting human subjects and successfully detected secondary, amalgam-occluded and early caries lesions without supplementary image processing. The camera-wand system was also capable of revealing demineralized areas, deep and superficial cracks, and other clinical features of teeth usually visualized by X-rays. The NIR system's clinical utility, simplistic design, low cost, and user friendliness make it an effective dental caries screening technology in conjunction or in place of radiographs.

  15. Application of the EM algorithm to radiographic images.

    PubMed

    Brailean, J C; Little, D; Giger, M L; Chen, C T; Sullivan, B J

    1992-01-01

    The expectation maximization (EM) algorithm has received considerable attention in the area of positron emitted tomography (PET) as a restoration and reconstruction technique. In this paper, the restoration capabilities of the EM algorithm when applied to radiographic images is investigated. This application does not involve reconstruction. The performance of the EM algorithm is quantitatively evaluated using a "perceived" signal-to-noise ratio (SNR) as the image quality metric. This perceived SNR is based on statistical decision theory and includes both the observer's visual response function and a noise component internal to the eye-brain system. For a variety of processing parameters, the relative SNR (ratio of the processed SNR to the original SNR) is calculated and used as a metric to compare quantitatively the effects of the EM algorithm with two other image enhancement techniques: global contrast enhancement (windowing) and unsharp mask filtering. The results suggest that the EM algorithm's performance is superior when compared to unsharp mask filtering and global contrast enhancement for radiographic images which contain objects smaller than 4 mm.

  16. Wavelet analysis methods for radiography of multidimensional growth of planar mixing layers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merritt, E. C., E-mail: emerritt@lanl.gov; Doss, F. W.

    2016-07-15

    The counter-propagating shear campaign is examining instability growth and its transition to turbulence in the high-energy-density physics regime using a laser-driven counter-propagating flow platform. In these experiments, we observe consistent complex break-up of and structure growth in a tracer layer placed at the shear flow interface during the instability growth phase. We present a wavelet-transform based analysis technique capable of characterizing the scale- and directionality-resolved average intensity perturbations in static radiographs of the experiment. This technique uses the complete spatial information available in each radiograph to describe the structure evolution. We designed this analysis technique to generate a two-dimensional powermore » spectrum for each radiograph from which we can recover information about structure widths, amplitudes, and orientations. The evolution of the distribution of power in the spectra for an experimental series is a potential metric for quantifying the structure size evolution as well as a system’s evolution towards isotropy.« less

  17. Dynamic changes in high and low mammographic density human breast tissues maintained in murine tissue engineering chambers during various murine peripartum states and over time.

    PubMed

    Chew, G L; Huang, D; Huo, C W; Blick, T; Hill, P; Cawson, J; Frazer, H; Southey, M D; Hopper, J L; Henderson, M A; Haviv, I; Thompson, E W

    2013-07-01

    Mammographic density (MD) is a strong heritable risk factor for breast cancer, and may decrease with increasing parity. However, the biomolecular basis for MD-associated breast cancer remains unclear, and systemic hormonal effects on MD-associated risk is poorly understood. This study assessed the effect of murine peripartum states on high and low MD tissue maintained in a xenograft model of human MD. Method High and low MD human breast tissues were precisely sampled under radiographic guidance from prophylactic mastectomy specimens of women. The high and low MD tissues were maintained in separate vascularised biochambers in nulliparous or pregnant SCID mice for 4 weeks, or mice undergoing postpartum involution or lactation for three additional weeks. High and low MD biochamber material was harvested for histologic and radiographic comparisons during various murine peripartum states. High and low MD biochamber tissues in nulliparous mice were harvested at different timepoints for histologic and radiographic comparisons. Results High MD biochamber tissues had decreased stromal (p = 0.0027), increased adipose (p = 0.0003) and a trend to increased glandular tissue areas (p = 0.076) after murine postpartum involution. Stromal areas decreased (p = 0.042), while glandular (p = 0.001) and adipose areas (p = 0.009) increased in high MD biochamber tissues during lactation. A difference in radiographic density was observed in high (p = 0.0021) or low MD biochamber tissues (p = 0.004) between nulliparous, pregnant and involution groups. No differences in tissue composition were observed in high or low MD biochamber tissues maintained for different durations, although radiographic density increased over time. Conclusion High MD biochamber tissues had measurable histologic changes after postpartum involution or lactation. Alterations in radiographic density occurred in biochamber tissues between different peripartum states and over time. These findings demonstrate the dynamic nature of the human MD xenograft model, providing a platform for studying the biomolecular basis of MD-associated cancer risk.

  18. Online Kidney Position Verification Using Non-Contrast Radiographs on a Linear Accelerator with on Board KV X-Ray Imaging Capability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willis, David J.; Kron, Tomas; Hubbard, Patricia

    2009-01-01

    The kidneys are dose-limiting organs in abdominal radiotherapy. Kilovoltage (kV) radiographs can be acquired using on-board imager (OBI)-equipped linear accelerators with better soft tissue contrast and lower radiation doses than conventional portal imaging. A feasibility study was conducted to test the suitability of anterior-posterior (AP) non-contrast kV radiographs acquired at treatment time for online kidney position verification. Anthropomorphic phantoms were used to evaluate image quality and radiation dose. Institutional Review Board approval was given for a pilot study that enrolled 5 adults and 5 children. Customized digitally reconstructed radiographs (DRRs) were generated to provide a priori information on kidney shapemore » and position. Radiotherapy treatment staff performed online evaluation of kidney visibility on OBI radiographs. Kidney dose measured in a pediatric anthropomorphic phantom was 0.1 cGy for kV imaging and 1.7 cGy for MV imaging. Kidneys were rated as well visualized in 60% of patients (90% confidence interval, 34-81%). The likelihood of visualization appears to be influenced by the relative AP separation of the abdomen and kidneys, the axial profile of the kidneys, and their relative contrast with surrounding structures. Online verification of kidney position using AP non-contrast kV radiographs on an OBI-equipped linear accelerator appears feasible for patients with suitable abdominal anatomy. Kidney position information provided is limited to 2-dimensional 'snapshots,' but this is adequate in some clinical situations and potentially advantageous in respiratory-correlated treatments. Successful clinical implementation requires customized partial DRRs, appropriate imaging parameters, and credentialing of treatment staff.« less

  19. The New Facilities for Neutron Radiography at the LVR-15 Reactor

    NASA Astrophysics Data System (ADS)

    Soltes, J.; Viererbl, L.; Vacik, J.; Tomandl, I.; Krejci, F.; Jakubek, J.

    2016-09-01

    Neutron radiography is an imaging method often used at research reactor sites. Back in 2011 a project was started with the goal to build a neutron radiography facility at the site of the LVR-15 research reactor in Rez, Czech Republic. In the scope of the project two horizontal channels were adapted for the needs of neutron radiography. This comprises the HC1 channel which offers an intense thermal neutron beam with a diameter of 10 cm, which can be used for imaging of larger samples, and the HC3 channel which beam is restricted just to 4x80 mm2, but is highly thermalized, collimated and reduced from gamma background, thus capable of providing better radiograph resolution. Both facilities are equipped with newest Timepix based detectors, with thin 6LiF converters for neutron detection capable of delivering high resolution. Both facilities offer a unique opportunity for non-destructive testing in the Czech region. In 2015 both facilities were put into test operation and several radiographs were acquired, which are presented in the following text.

  20. Radiographic and ultrasonic characterization of sintered silicon carbide

    NASA Technical Reports Server (NTRS)

    Baaklini, G. Y.; Abel, P. B.

    1988-01-01

    The capabilities were investigated of projection microfocus X-radiography, ultrasonic velocity and attenuation, and reflection scanning acoustic microscopy for characterizing silicon carbide specimens. Silicon carbide batches covered a range of densities and different microstructural characteristics. Room temperature, four point flexural strength tests were conducted. Fractography was used to identify types, sizes, and locations of fracture origins. Fracture toughness values were calculated from fracture strength and flaw characterization data. Detection capabilities of radiography and acoustic microscopy for fracture-causing flaws were evaluated. Applicability of ultrasonics for verifying material strength and toughness was examined.

  1. Use of radiography, computed tomography and magnetic resonance imaging for evaluation of navicular syndrome in the horse.

    PubMed

    Widmer, W R; Buckwalter, K A; Fessler, J F; Hill, M A; VanSickle, D C; Ivancevich, S

    2000-01-01

    Radiographic evaluation of navicular syndrome is problematic because of its inconsistent correlation with clinical signs. Scintigraphy often yields false positive and false negative results and diagnostic ultrasound is of limited value. Therefore, we assessed the use of computed tomography and magnetic resonance imaging in a horse with clinical and radiographic signs of navicular syndrome. Cadaver specimens were examined with spiral computed tomographic and high-field magnetic resonance scanners and images were correlated with pathologic findings. Radiographic changes consisted of bony remodeling, which included altered synovial fossae, increased medullary opacity, cyst formation and shape change. These osseous changes were more striking and more numerous on computed tomographic and magnetic resonance images. They were most clearly defined with computed tomography. Many osseous changes seen with computed tomography and magnetic resonance imaging were not radiographically evident. Histologically confirmed soft tissue alterations of the deep digital flexor tendon, impar ligament and marrow were identified with magnetic resonance imaging, but not with conventional radiography. Because of their multiplanar capability and tomographic nature, computed tomography and magnetic resonance imaging surpass conventional radiography for navicular imaging, facilitating earlier, more accurate diagnosis. Current advances in imaging technology should make these imaging modalities available to equine practitioners in the future.

  2. RELIABLE RADIOGRAPHIC INSPECTION OF FLEXIBLE RISERS FOR THE OIL INDUSTRY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Almeida, Romulo M.; Rebello, Joao Marcos A.; Vaz, Murilo A.

    2010-02-22

    Flexible risers are composite tubular structures manufactured by the concentric assemblage of cylindrical polymeric and helically wound metallic layers employed to convey pressurized fluids such as oil, gas and water in the ocean environment. The metallic layers account for the flexible risers' structural strength and are dimensioned according to the static and dynamic loads. They are usually installed in a free hanging catenary configuration and are subjected to the direct action of waves and marine currents and wave induced motions from the oil production platform. The fatigue rupture of wire armours in the end fitting or within the riser segmentmore » protected by the bend stiffener is an object of major concern. Integrity models have been developed, however inspection techniques are mandatory to ensure that failure is detected. Gammagraphy has been used as a common inspection technique in all regions of the flexible riser, mainly with the single wall-single view method. On the other side, there is not any qualified radiographic procedure to this kind of structure. Radiographic simulation was adopted and its validation with actual gammagraphies and establishment of radiographic parameters to complex radiation geometries were done. Results show the viability of the radiographic inspection analyzing the armour wires' rupture and the displacement between wires.« less

  3. Reliable Radiographic Inspection of Flexible Risers for the Oil Industry

    NASA Astrophysics Data System (ADS)

    Almeida, Rômulo M.; Rebello, Joao Marcos A.; Vaz, Murilo A.

    2010-02-01

    Flexible risers are composite tubular structures manufactured by the concentric assemblage of cylindrical polymeric and helically wound metallic layers employed to convey pressurized fluids such as oil, gas and water in the ocean environment. The metallic layers account for the flexible risers' structural strength and are dimensioned according to the static and dynamic loads. They are usually installed in a free hanging catenary configuration and are subjected to the direct action of waves and marine currents and wave induced motions from the oil production platform. The fatigue rupture of wire armours in the end fitting or within the riser segment protected by the bend stiffener is an object of major concern. Integrity models have been developed, however inspection techniques are mandatory to ensure that failure is detected. Gammagraphy has been used as a common inspection technique in all regions of the flexible riser, mainly with the single wall-single view method. On the other side, there is not any qualified radiographic procedure to this kind of structure. Radiographic simulation was adopted and its validation with actual gammagraphies and establishment of radiographic parameters to complex radiation geometries were done. Results show the viability of the radiographic inspection analyzing the armour wires' rupture and the displacement between wires.

  4. Segmentation of ribs in digital chest radiographs

    NASA Astrophysics Data System (ADS)

    Cong, Lin; Guo, Wei; Li, Qiang

    2016-03-01

    Ribs and clavicles in posterior-anterior (PA) digital chest radiographs often overlap with lung abnormalities such as nodules, and cause missing of these abnormalities, it is therefore necessary to remove or reduce the ribs in chest radiographs. The purpose of this study was to develop a fully automated algorithm to segment ribs within lung area in digital radiography (DR) for removal of the ribs. The rib segmentation algorithm consists of three steps. Firstly, a radiograph was pre-processed for contrast adjustment and noise removal; second, generalized Hough transform was employed to localize the lower boundary of the ribs. In the third step, a novel bilateral dynamic programming algorithm was used to accurately segment the upper and lower boundaries of ribs simultaneously. The width of the ribs and the smoothness of the rib boundaries were incorporated in the cost function of the bilateral dynamic programming for obtaining consistent results for the upper and lower boundaries. Our database consisted of 93 DR images, including, respectively, 23 and 70 images acquired with a DR system from Shanghai United-Imaging Healthcare Co. and from GE Healthcare Co. The rib localization algorithm achieved a sensitivity of 98.2% with 0.1 false positives per image. The accuracy of the detected ribs was further evaluated subjectively in 3 levels: "1", good; "2", acceptable; "3", poor. The percentages of good, acceptable, and poor segmentation results were 91.1%, 7.2%, and 1.7%, respectively. Our algorithm can obtain good segmentation results for ribs in chest radiography and would be useful for rib reduction in our future study.

  5. Quantumness-generating capability of quantum dynamics

    NASA Astrophysics Data System (ADS)

    Li, Nan; Luo, Shunlong; Mao, Yuanyuan

    2018-04-01

    We study quantumness-generating capability of quantum dynamics, where quantumness refers to the noncommutativity between the initial state and the evolving state. In terms of the commutator of the square roots of the initial state and the evolving state, we define a measure to quantify the quantumness-generating capability of quantum dynamics with respect to initial states. Quantumness-generating capability is absent in classical dynamics and hence is a fundamental characteristic of quantum dynamics. For qubit systems, we present an analytical form for this measure, by virtue of which we analyze several prototypical dynamics such as unitary dynamics, phase damping dynamics, amplitude damping dynamics, and random unitary dynamics (Pauli channels). Necessary and sufficient conditions for the monotonicity of quantumness-generating capability are also identified. Finally, we compare these conditions for the monotonicity of quantumness-generating capability with those for various Markovianities and illustrate that quantumness-generating capability and quantum Markovianity are closely related, although they capture different aspects of quantum dynamics.

  6. Beam Dynamics for ARIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ekdahl, Carl August Jr.

    2014-10-14

    Beam dynamics issues are assessed for a new linear induction electron accelerator being designed for flash radiography of large explosively driven hydrodynamic experiments. Special attention is paid to equilibrium beam transport, possible emittance growth, and beam stability. It is concluded that a radiographic quality beam will be produced possible if engineering standards and construction details are equivalent to those on the present radiography accelerators at Los Alamos.

  7. Quantitative kinetic analysis of lung nodules by temporal subtraction technique in dynamic chest radiography with a flat panel detector

    NASA Astrophysics Data System (ADS)

    Tsuchiya, Yuichiro; Kodera, Yoshie; Tanaka, Rie; Sanada, Shigeru

    2007-03-01

    Early detection and treatment of lung cancer is one of the most effective means to reduce cancer mortality; chest X-ray radiography has been widely used as a screening examination or health checkup. The new examination method and the development of computer analysis system allow obtaining respiratory kinetics by the use of flat panel detector (FPD), which is the expanded method of chest X-ray radiography. Through such changes functional evaluation of respiratory kinetics in chest has become available. Its introduction into clinical practice is expected in the future. In this study, we developed the computer analysis algorithm for the purpose of detecting lung nodules and evaluating quantitative kinetics. Breathing chest radiograph obtained by modified FPD was converted into 4 static images drawing the feature, by sequential temporal subtraction processing, morphologic enhancement processing, kinetic visualization processing, and lung region detection processing, after the breath synchronization process utilizing the diaphragmatic analysis of the vector movement. The artificial neural network used to analyze the density patterns detected the true nodules by analyzing these static images, and drew their kinetic tracks. For the algorithm performance and the evaluation of clinical effectiveness with 7 normal patients and simulated nodules, both showed sufficient detecting capability and kinetic imaging function without statistically significant difference. Our technique can quantitatively evaluate the kinetic range of nodules, and is effective in detecting a nodule on a breathing chest radiograph. Moreover, the application of this technique is expected to extend computer-aided diagnosis systems and facilitate the development of an automatic planning system for radiation therapy.

  8. Electron-Beam Dynamics for an Advanced Flash-Radiography Accelerator

    DOE PAGES

    Ekdahl, Carl

    2015-11-17

    Beam dynamics issues were assessed for a new linear induction electron accelerator being designed for multipulse flash radiography of large explosively driven hydrodynamic experiments. Special attention was paid to equilibrium beam transport, possible emittance growth, and beam stability. Especially problematic would be high-frequency beam instabilities that could blur individual radiographic source spots, low-frequency beam motion that could cause pulse-to-pulse spot displacement, and emittance growth that could enlarge the source spots. Furthermore, beam physics issues were examined through theoretical analysis and computer simulations, including particle-in-cell codes. Beam instabilities investigated included beam breakup, image displacement, diocotron, parametric envelope, ion hose, and themore » resistive wall instability. The beam corkscrew motion and emittance growth from beam mismatch were also studied. It was concluded that a beam with radiographic quality equivalent to the present accelerators at Los Alamos National Laboratory will result if the same engineering standards and construction details are upheld.« less

  9. Electron-beam dynamics for an advanced flash-radiography accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ekdahl, Carl August Jr.

    2015-06-22

    Beam dynamics issues were assessed for a new linear induction electron accelerator. Special attention was paid to equilibrium beam transport, possible emittance growth, and beam stability. Especially problematic would be high-frequency beam instabilities that could blur individual radiographic source spots, low-frequency beam motion that could cause pulse-to-pulse spot displacement, and emittance growth that could enlarge the source spots. Beam physics issues were examined through theoretical analysis and computer simulations, including particle-in cell (PIC) codes. Beam instabilities investigated included beam breakup (BBU), image displacement, diocotron, parametric envelope, ion hose, and the resistive wall instability. Beam corkscrew motion and emittance growth frommore » beam mismatch were also studied. It was concluded that a beam with radiographic quality equivalent to the present accelerators at Los Alamos will result if the same engineering standards and construction details are upheld.« less

  10. Computer-assisted instruction and diagnosis of radiographic findings.

    PubMed

    Harper, D; Butler, C; Hodder, R; Allman, R; Woods, J; Riordan, D

    1984-04-01

    Recent advances in computer technology, including high bit-density storage, digital imaging, and the ability to interface microprocessors with videodisk, create enormous opportunities in the field of medical education. This program, utilizing a personal computer, videodisk, BASIC language, a linked textfile system, and a triangulation approach to the interpretation of radiographs developed by Dr. W. L. Thompson, can enable the user to engage in a user-friendly, dynamic teaching program in radiology, applicable to various levels of expertise. Advantages include a relatively more compact and inexpensive system with rapid access and ease of revision which requires little instruction to the user.

  11. Dynamic calibration and analysis of crack tip propagation in energetic materials using real-time radiography

    NASA Astrophysics Data System (ADS)

    Butt, Ali

    Crack propagation in a solid rocket motor environment is difficult to measure directly. This experimental and analytical study evaluated the viability of real-time radiography for detecting bore regression and propellant crack propagation speed. The scope included the quantitative interpretation of crack tip velocity from simulated radiographic images of a burning, center-perforated grain and actual real-time radiographs taken on a rapid-prototyped model that dynamically produced the surface movements modeled in the simulation. The simplified motor simulation portrayed a bore crack that propagated radially at a speed that was 10 times the burning rate of the bore. Comparing the experimental image interpretation with the calibrated surface inputs, measurement accuracies were quantified. The average measurements of the bore radius were within 3% of the calibrated values with a maximum error of 7%. The crack tip speed could be characterized with image processing algorithms, but not with the dynamic calibration data. The laboratory data revealed that noise in the transmitted X-Ray intensity makes sensing the crack tip propagation using changes in the centerline transmitted intensity level impractical using the algorithms employed.

  12. Magnifying lens for 800 MeV proton radiography.

    PubMed

    Merrill, F E; Campos, E; Espinoza, C; Hogan, G; Hollander, B; Lopez, J; Mariam, F G; Morley, D; Morris, C L; Murray, M; Saunders, A; Schwartz, C; Thompson, T N

    2011-10-01

    This article describes the design and performance of a magnifying magnetic-lens system designed, built, and commissioned at the Los Alamos National Laboratory (LANL) for 800 MeV flash proton radiography. The technique of flash proton radiography has been developed at LANL to study material properties under dynamic loading conditions through the analysis of time sequences of proton radiographs. The requirements of this growing experimental program have resulted in the need for improvements in spatial radiographic resolution. To meet these needs, a new magnetic lens system, consisting of four permanent magnet quadrupoles, has been developed. This new lens system was designed to reduce the second order chromatic aberrations, the dominant source of image blur in 800 MeV proton radiography, as well as magnifying the image to reduce the blur contribution from the detector and camera systems. The recently commissioned lens system performed as designed, providing nearly a factor of three improvement in radiographic resolution.

  13. Magnifying lens for 800 MeV proton radiography

    NASA Astrophysics Data System (ADS)

    Merrill, F. E.; Campos, E.; Espinoza, C.; Hogan, G.; Hollander, B.; Lopez, J.; Mariam, F. G.; Morley, D.; Morris, C. L.; Murray, M.; Saunders, A.; Schwartz, C.; Thompson, T. N.

    2011-10-01

    This article describes the design and performance of a magnifying magnetic-lens system designed, built, and commissioned at the Los Alamos National Laboratory (LANL) for 800 MeV flash proton radiography. The technique of flash proton radiography has been developed at LANL to study material properties under dynamic loading conditions through the analysis of time sequences of proton radiographs. The requirements of this growing experimental program have resulted in the need for improvements in spatial radiographic resolution. To meet these needs, a new magnetic lens system, consisting of four permanent magnet quadrupoles, has been developed. This new lens system was designed to reduce the second order chromatic aberrations, the dominant source of image blur in 800 MeV proton radiography, as well as magnifying the image to reduce the blur contribution from the detector and camera systems. The recently commissioned lens system performed as designed, providing nearly a factor of three improvement in radiographic resolution.

  14. X-ray transmission movies of spontaneous dynamic events

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smilowitz, L.; Henson, B. F.; Holmes, M.

    2014-11-15

    We describe a new x-ray radiographic imaging system which allows for continuous x-ray transmission imaging of spontaneous dynamic events. We demonstrate this method on thermal explosions in three plastic bonded formulations of the energetic material octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine. We describe the x-ray imaging system and triggering developed to enable the continuous imaging of a thermal explosion.

  15. Long-term results of bone-retinaculum-bone autograft for scapholunate instability.

    PubMed

    Soong, Maximillian; Merrell, Gregory A; Ortmann, Fred; Weiss, Arnold-Peter C

    2013-03-01

    To report long-term follow-up of scapholunate interosseous ligament reconstruction with bone-retinaculum-bone autograft in patients with dynamic scapholunate instability. Of the 14 patients from the previously reported cohort who had bone-retinaculum-bone autograft for dynamic instability, 6 returned for clinical examination and radiographs, 3 were reached by telephone, and 2 were lost to follow-up. The remaining 3 had salvage procedures (2 total wrist arthrodeses and 1 proximal row carpectomy) between the prior report and the current study and thus reached an endpoint, at 2 to 4 years. For the 6 who returned, outcome measurements included scapholunate angle and gap, radiographic evidence of secondary arthritis, wrist extension and flexion, grip strength, and Mayo wrist score. Follow-up averaged 11.9 years (range, 10.7-14.1 y). Clinical and radiographic outcomes deteriorated moderately from the prior report. Mayo wrist score averaged 83. There were 3 failures, resulting in 1 proximal row carpectomy and 2 total wrist arthrodeses. Findings at repeat surgery in the failed group included an intact graft without any apparent abnormalities, a partially ruptured graft (after a subsequent re-injury), and a completely resorbed graft. Bone-retinaculum-bone autograft reconstruction is a viable treatment option for dynamic scapholunate instability in which the scaphoid and lunate can be reduced. Results may deteriorate but are similar to those reported previously from other techniques. Problems with graft strength or stiffness may necessitate further surgery. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  16. A stopping criterion to halt iterations at the Richardson-Lucy deconvolution of radiographic images

    NASA Astrophysics Data System (ADS)

    Almeida, G. L.; Silvani, M. I.; Souza, E. S.; Lopes, R. T.

    2015-07-01

    Radiographic images, as any experimentally acquired ones, are affected by spoiling agents which degrade their final quality. The degradation caused by agents of systematic character, can be reduced by some kind of treatment such as an iterative deconvolution. This approach requires two parameters, namely the system resolution and the best number of iterations in order to achieve the best final image. This work proposes a novel procedure to estimate the best number of iterations, which replaces the cumbersome visual inspection by a comparison of numbers. These numbers are deduced from the image histograms, taking into account the global difference G between them for two subsequent iterations. The developed algorithm, including a Richardson-Lucy deconvolution procedure has been embodied into a Fortran program capable to plot the 1st derivative of G as the processing progresses and to stop it automatically when this derivative - within the data dispersion - reaches zero. The radiograph of a specially chosen object acquired with thermal neutrons from the Argonauta research reactor at Institutode Engenharia Nuclear - CNEN, Rio de Janeiro, Brazil, have undergone this treatment with fair results.

  17. Intramedullary nailing: evolutions of femoral intramedullary nailing: first to fourth generations.

    PubMed

    Russell, Thomas A

    2011-12-01

    Intramedullary femoral nailing is the gold standard for femoral shaft fixation but only in the past 27 years. This rapid replacement of closed traction and cast techniques in North America was a controversial and contentious evolution in surgery. As we enter the fourth generation of implant design, capabilities, and surgical technique, it is important to understand the driving forces for this technology. These forces included changes in radiographic imaging capabilities, biomaterial design and computer-assisted manufacturing, and the recognition of the importance of mobilization of the trauma patient to avoid systemic complications and optimize functional recovery.

  18. Slump sitting X-ray of the lumbar spine is superior to the conventional flexion view in assessing lumbar spine instability.

    PubMed

    Hey, Hwee Weng Dennis; Lau, Eugene Tze-Chun; Lim, Joel-Louis; Choong, Denise Ai-Wen; Tan, Chuen-Seng; Liu, Gabriel Ka-Po; Wong, Hee-Kit

    2017-03-01

    Flexion radiographs have been used to identify cases of spinal instability. However, current methods are not standardized and are not sufficiently sensitive or specific to identify instability. This study aimed to introduce a new slump sitting method for performing lumbar spine flexion radiographs and comparison of the angular range of motions (ROMs) and displacements between the conventional method and this new method. This study used is a prospective study on radiological evaluation of the lumbar spine flexion ROMs and displacements using dynamic radiographs. Sixty patients were recruited from a single spine tertiary center. Angular and displacement measurements of lumbar spine flexion were carried out. Participants were randomly allocated into two groups: those who did the new method first, followed by the conventional method versus those who did the conventional method first, followed by the new method. A comparison of the angular and displacement measurements of lumbar spine flexion between the conventional method and the new method was performed and tested for superiority and non-inferiority. The measurements of global lumbar angular ROM were, on average, 17.3° larger (p<.0001) using the new slump sitting method compared with the conventional method. They were most significant at the levels of L3-L4, L4-L5, and L5-S1 (p<.0001, p<.0001 and p=.001, respectively). There was no significant difference between both methods when measuring lumbar displacements (p=.814). The new method of slump sitting dynamic radiograph was shown to be superior to the conventional method in measuring the angular ROM and non-inferior to the conventional method in the measurement of displacement. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Clinical outcomes and static and dynamic assessment of foot posture after lateral column lengthening procedure.

    PubMed

    Barske, Heather; Chimenti, Ruth; Tome, Josh; Martin, Elizabeth; Flemister, Adolph S; Houck, Jeff

    2013-05-01

    Lateral column lengthening (LCL) has been shown to radiographically restore the medial longitudinal arch. However, the impact of LCL on foot function during gait has not been reported using validated clinical outcomes and gait analysis. Thirteen patients with a stage II flatfoot who had undergone unilateral LCL surgery and 13 matched control subjects completed self-reported pain and functional scales as well as a clinical examination. A custom force transducer was used to establish the maximum passive range of motion of first metatarsal dorsiflexion at 40 N of force. Foot kinematic data were collected during gait using 3-dimensional motion analysis techniques. Radiographic correction of the flatfoot was achieved in all cases. Despite this, most patients continued to report pain and dysfunction postoperatively. Participants post LCL demonstrated similar passive and active movement of the medial column when we compared the operated and the nonoperated sides. However, participants post LCL demonstrated significantly greater first metatarsal passive range of motion and first metatarsal dorsiflexion during gait than did controls (P < .01 for all pairwise comparisons). Patients undergoing LCL for correction of stage II adult-acquired flatfoot deformity experience mixed outcomes and similar foot kinematics as the uninvolved limb despite radiographic correction of deformity. These patients maintain a low arch posture similar to their uninvolved limb. The consequence is that first metatarsal movement operates at the end range of dorsiflexion and patients do not obtain full hindfoot inversion at push-off. Longitudinal data are necessary to make a more valid comparison of the effects of surgical correction measured using radiographs and dynamic foot posture during gait. Level III, comparative series.

  20. Development of patient collation system by kinetic analysis for chest dynamic radiogram with flat panel detector

    NASA Astrophysics Data System (ADS)

    Tsuchiya, Yuichiro; Kodera, Yoshie

    2006-03-01

    In the picture archiving and communication system (PACS) environment, it is important that all images be stored in the correct location. However, if information such as the patient's name or identification number has been entered incorrectly, it is difficult to notice the error. The present study was performed to develop a system of patient collation automatically for dynamic radiogram examination by a kinetic analysis, and to evaluate the performance of the system. Dynamic chest radiographs during respiration were obtained by using a modified flat panel detector system. Our computer algorithm developed in this study was consisted of two main procedures, kinetic map imaging processing, and collation processing. Kinetic map processing is a new algorithm to visualize a movement for dynamic radiography; direction classification of optical flows and intensity-density transformation technique was performed. Collation processing consisted of analysis with an artificial neural network (ANN) and discrimination for Mahalanobis' generalized distance, those procedures were performed to evaluate a similarity of combination for the same person. Finally, we investigated the performance of our system using eight healthy volunteers' radiographs. The performance was shown as a sensitivity and specificity. The sensitivity and specificity for our system were shown 100% and 100%, respectively. This result indicated that our system has excellent performance for recognition of a patient. Our system will be useful in PACS management for dynamic chest radiography.

  1. Diaphragm breathing movement measurement using ultrasound and radiographic imaging: a concurrent validity.

    PubMed

    Noh, Dong K; Lee, Jae J; You, Joshua H

    2014-01-01

    Recent ultrasound imaging evidence asserts that the diaphragm is an important multifunctional muscle to control breathing as well as stabilize the core and posture in humans. However, the validity and accuracy of ultrasound for the measurement of dynamic diaphragm movements during breathing and functional core activities have not been determined. The specific aim of this study was to validate the accuracy of ultrasound imaging measurements of diaphragm movements by concurrently comparing these measurements to the gold standard of radiographic imaging measurements. A total of 14 asymptomatic adults (9 males, 5 females; mean age =28.4 ± 3.0 years) were recruited to participate in the study. Ultrasound and radiographic images were used concurrently to determine diaphragm movement (inspiration, expiration, and excursion) during tidal breathing. Pearson correlation analysis showed strong correlations, ranging from r=0.78 to r=0.83, between ultrasound and radiographic imaging measurements of the diaphragm during inhalation, exhalation, and excursion. These findings suggest that ultrasound imaging measurement is useful to accurately evaluate diaphragm movements during tidal breathing. Clinically, ultrasound imaging measurements can be used to diagnose and treat diaphragm movement impairments in individuals with neuromuscular disorders including spinal cord injuries, stroke, and multiple sclerosis.

  2. Quantitative analysis of rib movement based on dynamic chest bone images: preliminary results

    NASA Astrophysics Data System (ADS)

    Tanaka, R.; Sanada, S.; Oda, M.; Mitsutaka, M.; Suzuki, K.; Sakuta, K.; Kawashima, H.

    2014-03-01

    Rib movement during respiration is one of the diagnostic criteria in pulmonary impairments. In general, the rib movement is assessed in fluoroscopy. However, the shadows of lung vessels and bronchi overlapping ribs prevent accurate quantitative analysis of rib movement. Recently, an image-processing technique for separating bones from soft tissue in static chest radiographs, called "bone suppression technique", has been developed. Our purpose in this study was to evaluate the usefulness of dynamic bone images created by the bone suppression technique in quantitative analysis of rib movement. Dynamic chest radiographs of 10 patients were obtained using a dynamic flat-panel detector (FPD). Bone suppression technique based on a massive-training artificial neural network (MTANN) was applied to the dynamic chest images to create bone images. Velocity vectors were measured in local areas on the dynamic bone images, which formed a map. The velocity maps obtained with bone and original images for scoliosis and normal cases were compared to assess the advantages of bone images. With dynamic bone images, we were able to quantify and distinguish movements of ribs from those of other lung structures accurately. Limited rib movements of scoliosis patients appeared as reduced rib velocity vectors. Vector maps in all normal cases exhibited left-right symmetric distributions, whereas those in abnormal cases showed nonuniform distributions. In conclusion, dynamic bone images were useful for accurate quantitative analysis of rib movements: Limited rib movements were indicated as a reduction of rib movement and left-right asymmetric distribution on vector maps. Thus, dynamic bone images can be a new diagnostic tool for quantitative analysis of rib movements without additional radiation dose.

  3. A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets.

    PubMed

    Jaffray, D A; Drake, D G; Moreau, M; Martinez, A A; Wong, J W

    1999-10-01

    Dose escalation in conformal radiation therapy requires accurate field placement. Electronic portal imaging devices are used to verify field placement but are limited by the low subject contrast of bony anatomy at megavoltage (MV) energies, the large imaging dose, and the small size of the radiation fields. In this article, we describe the in-house modification of a medical linear accelerator to provide radiographic and tomographic localization of bone and soft-tissue targets in the reference frame of the accelerator. This system separates the verification of beam delivery (machine settings, field shaping) from patient and target localization. A kilovoltage (kV) x-ray source is mounted on the drum assembly of an Elekta SL-20 medical linear accelerator, maintaining the same isocenter as the treatment beam with the central axis at 90 degrees to the treatment beam axis. The x-ray tube is powered by a high-frequency generator and can be retracted to the drum-face. Two CCD-based fluoroscopic imaging systems are mounted on the accelerator to collect MV and kV radiographic images. The system is also capable of cone-beam tomographic imaging at both MV and kV energies. The gain stages of the two imaging systems have been modeled to assess imaging performance. The contrast-resolution of the kV and MV systems was measured using a contrast-detail (C-D) phantom. The dosimetric advantage of using the kV imaging system over the MV system for the detection of bone-like objects is quantified for a specific imaging geometry using a C-D phantom. Accurate guidance of the treatment beam requires registration of the imaging and treatment coordinate systems. The mechanical characteristics of the treatment and imaging gantries are examined to determine a localizing precision assuming an unambiguous object. MV and kV radiographs of patients receiving radiation therapy are acquired to demonstrate the radiographic performance of the system. The tomographic performance is demonstrated on phantoms using both the MV and the kV imaging system, and the visibility of soft-tissue targets is assessed. Characterization of the gains in the two systems demonstrates that the MV system is x-ray quantum noise-limited at very low spatial frequencies; this is not the case for the kV system. The estimates of gain used in the model are validated by measurements of the total gain in each system. Contrast-detail measurements demonstrate that the MV system is capable of detecting subject contrasts of less than 0.1% (at 6 and 18 MV). A comparison of the kV and MV contrast-detail performance indicates that equivalent bony object detection can be achieved with the kV system at significantly lower doses (factors of 40 and 90 lower than for 6 and 18 MV, respectively). The tomographic performance of the system is promising; soft-tissue visibility is demonstrated at relatively low imaging doses (3 cGy) using four laboratory rats. We have integrated a kV radiographic and tomographic imaging system with a medical linear accelerator to allow localization of bone and soft-tissue structures in the reference frame of the accelerator. Modeling and experiments have demonstrated the feasibility of acquiring high-quality radiographic and tomographic images at acceptable imaging doses. Full integration of the kV and MV imaging systems with the treatment machine will allow on-line radiographic and tomographic guidance of field placement.

  4. Sonographic prevalence of groin hernias and adductor tendinopathy in patients with femoroacetabular impingement.

    PubMed

    Naal, Florian D; Dalla Riva, Francesco; Wuerz, Thomas H; Dubs, Beat; Leunig, Michael

    2015-09-01

    Femoroacetabular impingement (FAI) is a common debilitating condition that is associated with groin pain and limitation in young and active patients. Besides FAI, various disorders such as hernias, adductor tendinopathy, athletic pubalgia, lumbar spine affections, and others can cause similar symptoms. To determine the prevalence of inguinal and/or femoral herniation and adductor insertion tendinopathy using dynamic ultrasound in a cohort of patients with radiographic evidence of FAI. Case series; Level of evidence, 4. This retrospective study consisted of 74 patients (36 female and 38 male; mean age, 29 years; 83 symptomatic hips) with groin pain and radiographic evidence of FAI. In addition to the usual diagnostic algorithm, all patients underwent a dynamic ultrasound examination for signs of groin herniation and tendinopathy of the proximal insertion of the adductors. Evidence of groin herniation was found in 34 hips (41%). There were 27 inguinal (6 female, 21 male) and 10 femoral (9 female, 1 male) hernias. In 3 cases, inguinal and femoral herniation was coexistent. Overall, 5 patients underwent subsequent hernia repair. Patients with groin herniation were significantly older than those without (33 vs 27 years, respectively; P = .01). There were no significant differences for any of the radiographic or clinical parameters. Tendinopathy of the proximal adductor insertion was detected in 19 cases (23%; 11 female, 8 male). Tendinopathy was coexistent with groin herniation in 8 of the 19 cases. There were no significant differences for any of the radiographic or clinical parameters between patients with or without tendinopathy. Patients with a negative diagnostic hip injection result were more likely to have a concomitant groin hernia than those with a positive injection result (80% vs 27%, respectively). Overall, 38 hips underwent FAI surgery with satisfactory outcomes in terms of score values and subjective improvement. The results demonstrate that groin herniation and adductor insertion tendinopathy coexist frequently in patients with FAI. Although the clinical effect is yet unclear, 5 patients underwent hernia repair. Dynamic ultrasound is a useful tool to detect such pathological abnormalities. Diagnostic hip injections can be helpful to differentiate between the sources of pain. © 2015 The Author(s).

  5. A new method of scoring radiographic change in rheumatoid arthritis.

    PubMed

    Rau, R; Wassenberg, S; Herborn, G; Stucki, G; Gebler, A

    1998-11-01

    To test the reliability and to define the minimal detectable change of a new radiographic scoring method in rheumatoid arthritis (RA). Following the recommendations of an expert panel a new radiographic scoring method was defined. It scores 38 joints [all proximal interphalangeal (PIP) and metacarpophalangeal joints, 4 sites in the wrists, IP of the great toes, and metatarsophalangeals 2 to 5], regarding only the amount of joint surface destruction on a 0 to 5 scale for each joint. Each grade represents 20% of joint surface destruction. The method was tested by 5 readers on a set of 7 serial radiographs of hands and forefeet of 20 patients with progressive and destructive RA. Analysis of variance was performed, as it provides the best information about the capability of a method to detect real change and to define its sensitivity according to the minimal detectable change. Analysis of variance proved a high probability that the readers found real change with a ratio of intrapatient to intrareader standard deviation of 2.6. It also confirmed that one reader could detect a change of 3.5% of the total score with a probability of 95% and that different readers agreed upon a change of 4.6%. Inexperienced readers performed with comparable results to experienced readers. The time required for the reading averaged less than 10 minutes for the scoring of one set. The new radiographic scoring method proved to be reliable, precise, and easy to learn, with reasonable cost. Compared to published data, it may provide better results than the widely used Larsen score. These features favor our new method for use in clinical trials and in longterm observational studies in RA.

  6. The influence of radiographic viewing perspective and demographics on the Critical Shoulder Angle

    PubMed Central

    Suter, Thomas; Popp, Ariane Gerber; Zhang, Yue; Zhang, Chong; Tashjian, Robert Z.; Henninger, Heath B.

    2014-01-01

    Background Accurate assessment of the critical shoulder angle (CSA) is important in clinical evaluation of degenerative rotator cuff tears. This study analyzed the influence of radiographic viewing perspective on the CSA, developed a classification system to identify malpositioned radiographs, and assessed the relationship between the CSA and demographic factors. Methods Glenoid height, width and retroversion were measured on 3D CT reconstructions of 68 cadaver scapulae. A digitally reconstructed radiograph was aligned perpendicular to the scapular plane, and retroversion was corrected to obtain a true antero-posterior (AP) view. In 10 scapulae, incremental anteversion/retroversion and flexion/extension views were generated. The CSA was measured and a clinically applicable classification system was developed to detect views with >2° change in CSA versus true AP. Results The average CSA was 33±4°. Intra- and inter-observer reliability was high (ICC≥0.81) but decreased with increasing viewing angle. Views beyond 5° anteversion, 8° retroversion, 15° flexion and 26° extension resulted in >2° deviation of the CSA compared to true AP. The classification system was capable of detecting aberrant viewing perspectives with sensitivity of 95% and specificity of 53%. Correlations between glenoid size and CSA were small (R≤0.3), and CSA did not vary by gender (p=0.426) or side (p=0.821). Conclusions The CSA was most susceptible to malposition in ante/retroversion. Deviations as little as 5° in anteversion resulted in a CSA >2° from true AP. A new classification system refines the ability to collect true AP radiographs of the scapula. The CSA was unaffected by demographic factors. PMID:25591458

  7. Medipix2 based CdTe microprobe for dental imaging

    NASA Astrophysics Data System (ADS)

    Vykydal, Z.; Fauler, A.; Fiederle, M.; Jakubek, J.; Svestkova, M.; Zwerger, A.

    2011-12-01

    Medical imaging devices and techniques are demanded to provide high resolution and low dose images of samples or patients. Hybrid semiconductor single photon counting devices together with suitable sensor materials and advanced techniques of image reconstruction fulfil these requirements. In particular cases such as the direct observation of dental implants also the size of the imaging device itself plays a critical role. This work presents the comparison of 2D radiographs of tooth provided by a standard commercial dental imaging system (Gendex 765DC X-ray tube with VisualiX scintillation detector) and two Medipix2 USB Lite detectors one equipped with a Si sensor (300 μm thick) and one with a CdTe sensor (1 mm thick). Single photon counting capability of the Medipix2 device allows virtually unlimited dynamic range of the images and thus increases the contrast significantly. The dimensions of the whole USB Lite device are only 15 mm × 60 mm of which 25% consists of the sensitive area. Detector of this compact size can be used directly inside the patients' mouth.

  8. Design and testing of artifact-suppressed adaptive histogram equalization: a contrast-enhancement technique for display of digital chest radiographs.

    PubMed

    Rehm, K; Seeley, G W; Dallas, W J; Ovitt, T W; Seeger, J F

    1990-01-01

    One of the goals of our research in the field of digital radiography has been to develop contrast-enhancement algorithms for eventual use in the display of chest images on video devices with the aim of preserving the diagnostic information presently available with film, some of which would normally be lost because of the smaller dynamic range of video monitors. The ASAHE algorithm discussed in this article has been tested by investigating observer performance in a difficult detection task involving phantoms and simulated lung nodules, using film as the output medium. The results of the experiment showed that the algorithm is successful in providing contrast-enhanced, natural-looking chest images while maintaining diagnostic information. The algorithm did not effect an increase in nodule detectability, but this was not unexpected because film is a medium capable of displaying a wide range of gray levels. It is sufficient at this stage to show that there is no degradation in observer performance. Future tests will evaluate the performance of the ASAHE algorithm in preparing chest images for video display.

  9. Health information technology and dynamic capabilities.

    PubMed

    Leung, Ricky C

    2012-01-01

    Health information technology (HIT) purports to increase quality and efficiency in health care organizations. However, health care organizations are situated in constantly changing environments. They need dynamic capabilities to implement HIT effectively. This article builds on the dynamic capabilities perspective and generates propositions about implementing HIT in dynamic environments. Specifically, I identify the (1) the necessary resources and capabilities for organizations to implement HIT; (2) the organizational capabilities and benefits that can be enhanced by HIT; and (3) the similarities and differences between three distinct forms of HIT. I synthesized the literature on dynamic capabilities and HIT to identify dynamic capabilities that are associated with (1) electronic medical records, (2) telemedicine, and (3) social media. In addition, I discuss the benefits of these HITs for improving the dynamic capabilities of health care organizations. PROPOSITIONS/FINDINGS: This article generates three sets of propositions that can be tested empirically. First, I am concerned with how organizational size and human resources affect successful implementation of HIT. In addition, I argue that three technology-specific factors--hospital type, medical specialty, and socially desirable technical features--may affect the implementation of HIT. To cope with constantly changing environmental pressures, health administrators need to deploy, modify, and/or acquire organizational resources skillfully. Practitioners need to identify dynamic capabilities to support specific forms of HIT and understand how HIT enables health care organizations in turn. The concept of evolutionary fitness in the dynamic capabilities perspective may be developed to measure HIT implementation.

  10. Dynamic Stress Testing Is Unnecessary for Unimalleolar Supination-External Rotation Ankle Fractures with Minimal Fracture Displacement on Lateral Radiographs.

    PubMed

    Nortunen, Simo; Leskelä, Hannu-Ville; Haapasalo, Heidi; Flinkkilä, Tapio; Ohtonen, Pasi; Pakarinen, Harri

    2017-03-15

    This study aimed to identify factors from standard radiographs that contributed to the stability of the ankle mortise in patients with isolated supination-external rotation fractures of the lateral malleolus (OTA/AO 44-B). Non-stress radiographs of the mortise and lateral views, without medial clear space widening or incongruity, were prospectively collected for 286 consecutive patients (mean age, 45 years [range, 16 to 85 years]), including 144 female patients (mean age, 50 years [range, 17 to 85 years]) and 142 male patients (mean age, 40 years [range, 16 to 84 years]) from 2 trauma centers. The radiographs were analyzed for fracture morphology by 2 orthopaedic surgeons, who were blinded to each other's measurements and to the results of external rotation stress radiographs (the reference for stability). Factors significantly associated with ankle mortise stability were tested in multiple logistic regression. Receiver operating characteristic analyses were performed for continuous variables to determine optimal thresholds. A sensitivity of >90% was used as the criterion for an optimal threshold. According to external rotation stress radiographs, 217 patients (75.9%) had a stable injury, defined as that with a medial clear space of <5 mm. Independent factors that predicted stable ankle mortise were female sex (odds ratio [OR], 2.5 [95% confidence interval (CI), 1.4 to 4.6]), a posterior diastasis of <2 mm (corresponding with a sensitivity of 0.94 and specificity of 0.39) on lateral radiographs (OR, 10.8 [95% CI, 3.7 to 31.5]), and only 2 fracture fragments (OR, 7.3 [95% CI, 2.1 to 26.3]). When the posterior diastasis was <2 mm and only 2 fracture fragments were present, the probability of a stable ankle mortise was 0.98 for 48 female patients (16.8%) and 0.94 for 37 male patients (12.9%). Patients with noncomminuted lateral malleolar fractures (85 patients [29.7%]) could be diagnosed with a stable ankle mortise without further stress testing, when the fracture line widths were <2 mm on lateral radiographs. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  11. Evaluation of a gamma camera system for the RITS-6 accelerator using the self-magnetic pinch diode

    NASA Astrophysics Data System (ADS)

    Webb, Timothy J.; Kiefer, Mark L.; Gignac, Raymond; Baker, Stuart A.

    2015-08-01

    The self-magnetic pinch (SMP) diode is an intense radiographic source fielded on the Radiographic Integrated Test Stand (RITS-6) accelerator at Sandia National Laboratories in Albuquerque, NM. The accelerator is an inductive voltage adder (IVA) that can operate from 2-10 MV with currents up to 160 kA (at 7 MV). The SMP diode consists of an annular cathode separated from a flat anode, holding the bremsstrahlung conversion target, by a vacuum gap. Until recently the primary imaging diagnostic utilized image plates (storage phosphors) which has generally low DQE at these photon energies along with other problems. The benefits of using image plates include a high-dynamic range, good spatial resolution, and ease of use. A scintillator-based X-ray imaging system or "gamma camera" has been fielded in front of RITS and the SMP diode which has been able to provide vastly superior images in terms of signal-to-noise with similar resolution and acceptable dynamic range.

  12. Scatter Reduction In Conventional Radiographic Tomography Using Rotating Apertures

    NASA Astrophysics Data System (ADS)

    Rudin, Stephen; Bednarek, Daniel R.

    1981-08-01

    Since images in conventional radiographic tomography are in-herently low in subject contrast, it is essential that scattered radiation be prevented from reaching the image receptor. Scanning beam or slit radiographic techniques are known to be the most efficient scatter elimination methods, yet have been inapplicable to this area of radiography. In this work it is shown that the scanning beam method using rotating aperture wheel (RAW) devices can be used in conventional tomography. One coder wheel between the x-ray tube and patient and two scatter discriminator wheels between the patient and image recep-tor form sections of the RAW "projection cone" with the lines of radia-tion from the x-ray source forming the "flux pyramid." As long as the projection cone follows the motion of the x-ray flux pyramid (with the ratios of the distances between the x-ray source, RAWs, patient, and image receptor kept constant throughout the motion) any RAW pattern may be used. Simple relations are given which describe the geometric constraints for various tomographic motions. As in any application of scanning slit techniques, it is possible to use the excellent scatter elimination capabilities of a RAW device either to improve image contrast or to reduce patient dose.

  13. TeleMed: An example of a new system developed with object technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Forslund, D.; Phillips, R.; Tomlinson, B.

    1996-12-01

    Los Alamos National Laboratory has developed a virtual patient record system called TeleMed which is based on a distributed national radiographic and patient record repository located throughout the country. Without leaving their offices, participating doctors can view clinical drug and radiographic data via a sophisticated multimedia interface. For example, a doctor can match a patient`s radiographic information with the data in the repository, review treatment history and success, and then determine the best treatment. Furthermore, the features of TeleMed that make it attractive to clinicians and diagnosticians make it valuable for teaching and presentation as well. Thus, a resident canmore » use TeleMed for self-training in diagnostic techniques and a physician can use it to explain to a patient the course of their illness. In fact, the data can be viewed simultaneously by users at two or more distant locations for consultation with specialists in different fields. This capability is of enormous value to a wide spectrum of healthcare providers. It is made possible by the integration of multimedia information using commercial CORBA technology linking object-enabled databases with client interfaces using a three-tiered architecture.« less

  14. A 7.2 keV spherical x-ray crystal backlighter for two-frame, two-color backlighting at Sandia's Z Pulsed Power Facility

    NASA Astrophysics Data System (ADS)

    Schollmeier, M. S.; Knapp, P. F.; Ampleford, D. J.; Harding, E. C.; Jennings, C. A.; Lamppa, D. C.; Loisel, G. P.; Martin, M. R.; Robertson, G. K.; Shores, J. E.; Smith, I. C.; Speas, C. S.; Weis, M. R.; Porter, J. L.; McBride, R. D.

    2017-10-01

    Many experiments on Sandia National Laboratories' Z Pulsed Power Facility—a 30 MA, 100 ns rise-time, pulsed-power driver—use a monochromatic quartz crystal backlighter system at 1.865 keV (Si He α ) or 6.151 keV (Mn He α ) x-ray energy to radiograph an imploding liner (cylindrical tube) or wire array z-pinch. The x-ray source is generated by the Z-Beamlet laser, which provides two 527-nm, 1 kJ, 1-ns laser pulses. Radiographs of imploding, thick-walled beryllium liners at convergence ratios CR above 15 [ C R = r i ( 0 ) / r i ( t ) ] using the 6.151-keV backlighter system were too opaque to identify the inner radius r i of the liner with high confidence, demonstrating the need for a higher-energy x-ray radiography system. Here, we present a 7.242 keV backlighter system using a Ge(335) spherical crystal with the Co He α resonance line. This system operates at a similar Bragg angle as the existing 1.865 keV and 6.151 keV backlighters, enhancing our capabilities for two-color, two-frame radiography without modifying the system integration at Z. The first data taken at Z include 6.2-keV and 7.2-keV two-color radiographs as well as radiographs of low-convergence (CR about 4-5), high-areal-density liner implosions.

  15. The x-ray light valve: a potentially low-cost, digital radiographic imaging system-concept and implementation considerations.

    PubMed

    Webster, Christie Ann; Koprinarov, Ivaylo; Germann, Stephen; Rowlands, J A

    2008-03-01

    New x-ray radiographic systems based on large-area flat-panel technology have revolutionized our capability to produce digital x-ray images. However, these imagers are extraordinarily expensive compared to the systems they are replacing. Hence, there is a need for a low-cost digital imaging system for general applications in radiology. A novel potentially low-cost radiographic imaging system based on established technologies is proposed-the X-Ray Light Valve (XLV). This is a potentially high-quality digital x-ray detector made of a photoconducting layer and a liquid-crystal cell, physically coupled in a sandwich structure. Upon exposure to x rays, charge is collected on the surface of the photoconductor. This causes a change in the optical properties of the liquid-crystal cell and a visible image is generated. Subsequently, it is digitized by a scanned optical imager. The image formation is based on controlled modulation of light from an external source. The operation and practical implementation of the XLV system are described. The potential performance of the complete system and issues related to sensitivity, spatial resolution, noise, and speed are discussed. The feasibility of clinical use of an XLV device based on amorphous selenium (a-Se) as the photoconductor and a reflective electrically controlled birefringence cell is analyzed. The results of our analysis indicate that the XLV can potentially be adapted to a wide variety of radiographic tasks.

  16. A 7.2 keV spherical x-ray crystal backlighter for two-frame, two-color backlighting at Sandia’s Z Pulsed Power Facility

    DOE PAGES

    Schollmeier, M. S.; Knapp, P. F.; Ampleford, D. J.; ...

    2017-10-10

    Many experiments on Sandia National Laboratories’ Z Pulsed Power Facility—a 30 MA, 100 ns rise-time, pulsed-power driver—use a monochromatic quartz crystal backlighter system at 1.865 keV (Si He α) or 6.151 keV (Mn He α) x-ray energy to radiograph an imploding liner (cylindrical tube) or wire array z-pinch. The x-ray source is generated by the Z-Beamlet laser, which provides two 527-nm, 1 kJ, 1-ns laser pulses. Radiographs of imploding, thick-walled beryllium liners at convergence ratios C R above 15 [C R=r i(0)/r i(t)] using the 6.151-keV backlighter system were too opaque to identify the inner radius ri of the linermore » with high confidence, demonstrating the need for a higher-energy x-ray radiography system. Here, we present a 7.242 keV backlighter system using a Ge(335) spherical crystal with the Co He α resonance line. This system operates at a similar Bragg angle as the existing 1.865 keV and 6.151 keV backlighters, enhancing our capabilities for two-color, two-frame radiography without modifying the system integration at Z. The first data taken at Z include 6.2-keV and 7.2-keV two-color radiographs as well as radiographs of low-convergence (C R about 4-5), high-areal-density liner implosions.« less

  17. A 7.2 keV spherical x-ray crystal backlighter for two-frame, two-color backlighting at Sandia’s Z Pulsed Power Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schollmeier, M. S.; Knapp, P. F.; Ampleford, D. J.

    Many experiments on Sandia National Laboratories’ Z Pulsed Power Facility—a 30 MA, 100 ns rise-time, pulsed-power driver—use a monochromatic quartz crystal backlighter system at 1.865 keV (Si He α) or 6.151 keV (Mn He α) x-ray energy to radiograph an imploding liner (cylindrical tube) or wire array z-pinch. The x-ray source is generated by the Z-Beamlet laser, which provides two 527-nm, 1 kJ, 1-ns laser pulses. Radiographs of imploding, thick-walled beryllium liners at convergence ratios C R above 15 [C R=r i(0)/r i(t)] using the 6.151-keV backlighter system were too opaque to identify the inner radius ri of the linermore » with high confidence, demonstrating the need for a higher-energy x-ray radiography system. Here, we present a 7.242 keV backlighter system using a Ge(335) spherical crystal with the Co He α resonance line. This system operates at a similar Bragg angle as the existing 1.865 keV and 6.151 keV backlighters, enhancing our capabilities for two-color, two-frame radiography without modifying the system integration at Z. The first data taken at Z include 6.2-keV and 7.2-keV two-color radiographs as well as radiographs of low-convergence (C R about 4-5), high-areal-density liner implosions.« less

  18. Monte-Carlo Geant4 numerical simulation of experiments at 247-MeV proton microscope

    NASA Astrophysics Data System (ADS)

    Kantsyrev, A. V.; Skoblyakov, A. V.; Bogdanov, A. V.; Golubev, A. A.; Shilkin, N. S.; Yuriev, D. S.; Mintsev, V. B.

    2018-01-01

    A radiographic facility for an investigation of fast dynamic processes with areal density of targets up to 5 g/cm2 is under development on the basis of high-current proton linear accelerator at the Institute for Nuclear Research (Troitsk, Russia). A virtual model of the proton microscope developed in a software toolkit Geant4 is presented in the article. Fullscale Monte-Carlo numerical simulation of static radiographic experiments at energy of a proton beam 247 MeV was performed. The results of simulation of proton radiography experiments with static model of shock-compressed xenon are presented. The results of visualization of copper and polymethyl methacrylate step wedges static targets also described.

  19. [Mobility of a polyethylene tibial insert in a mobile total knee prosthesis].

    PubMed

    Castel, E; Roger, B; Camproux, A; Saillant, G

    1999-03-01

    We have studied the mobility of a mobile tibial implant in total knee arthroplasty (TKA) by a radiographical evaluation. We analyzed mobility of the polyethylene tibial insert of 15 "G2S" TKA implanted for one year or more. We established a dynamic radiographical evaluation. We used 3 weight-bearing radiographs: AP in extension and two lateral (one in extension and one at 90 degrees of flexion), two AP with femoral internal and external rotation, 2 strict lateral X-rays in neutral rotation in antero-posterior replacement with a 25 kilograms strength Telos, and 2 AP in varus and valgus with Telos. Wilcoxon's test and Fisher's exact test were used for statistical evaluation. Our study demonstrated preservation of the polyethylene mobility in tibial TKA implant in all movements: in rotation, in antero-posterior translation with Telos, and even in antero-posterior translation during physiological condition with flexion-extension weight-bearing radiographs. Statistical tests were very significant. We noticed that flexion induced anterior translation of tibial polyethylene when PCL was preserved. This study answered to our question whether mobility of TKA tibial implant persists after implantation. This mobility should reduce loosening forces to the tibia and stress in the polyethylene component. Now we have to determine the amplitude of mobility required to reach this objective.

  20. Assessment and Mitigation of Electromagnetic Pulse (EMP) Impacts at Short-pulse Laser Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Jr., C G; Bond, E; Clancy, T

    2009-10-02

    The National Ignition Facility (NIF) will be impacted by electromagnetic pulse (EMP) during normal long-pulse operation, but the largest impacts are expected during short-pulse operation utilizing the Advanced Radiographic Capability (ARC). Without mitigation these impacts could range from data corruption to hardware damage. We describe our EMP measurement systems on Titan and NIF and present some preliminary results and thoughts on mitigation.

  1. Assessment and Mitigation of Electromagnetic Pulse (EMP) Impacts at Short-pulse Laser Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Jr., C G; Bond, E; Clancy, T

    2010-02-04

    The National Ignition Facility (NIF) will be impacted by electromagnetic pulse (EMP) during normal long-pulse operation, but the largest impacts are expected during short-pulse operation utilizing the Advanced Radiographic Capability (ARC). Without mitigation these impacts could range from data corruption to hardware damage. We describe our EMP measurement systems on Titan and NIF and present some preliminary results and thoughts on mitigation.

  2. Fully automated calculation of cardiothoracic ratio in digital chest radiographs

    NASA Astrophysics Data System (ADS)

    Cong, Lin; Jiang, Luan; Chen, Gang; Li, Qiang

    2017-03-01

    The calculation of Cardiothoracic Ratio (CTR) in digital chest radiographs would be useful for cardiac anomaly assessment and heart enlargement related disease indication. The purpose of this study was to develop and evaluate a fully automated scheme for calculation of CTR in digital chest radiographs. Our automated method consisted of three steps, i.e., lung region localization, lung segmentation, and CTR calculation. We manually annotated the lung boundary with 84 points in 100 digital chest radiographs, and calculated an average lung model for the subsequent work. Firstly, in order to localize the lung region, generalized Hough transform was employed to identify the upper, lower, and outer boundaries of lung by use of Sobel gradient information. The average lung model was aligned to the localized lung region to obtain the initial lung outline. Secondly, we separately applied dynamic programming method to detect the upper, lower, outer and inner boundaries of lungs, and then linked the four boundaries to segment the lungs. Based on the identified outer boundaries of left lung and right lung, we corrected the center and the declination of the original radiography. Finally, CTR was calculated as a ratio of the transverse diameter of the heart to the internal diameter of the chest, based on the segmented lungs. The preliminary results on 106 digital chest radiographs showed that the proposed method could obtain accurate segmentation of lung based on subjective observation, and achieved sensitivity of 88.9% (40 of 45 abnormalities), and specificity of 100% (i.e. 61 of 61 normal) for the identification of heart enlargements.

  3. Exploring Richtmyer-Meshkov instability phenomena and ejecta cloud physics

    NASA Astrophysics Data System (ADS)

    Zellner, M. B.; Buttler, W. T.

    2008-09-01

    This effort investigates ejecta cloud expansion from a shocked Sn target propagating into vacuum. To assess the expansion, dynamic ejecta cloud density distributions were measured via piezoelectric pin diagnostics offset at three heights from the target free surface. The dynamic distributions were first converted into static distributions, similar to a radiograph, and then self compared. The cloud evolved self-similarly at the distances and times measured, inferring that the amount of mass imparted to the instability, detected as ejecta, either ceased or approached an asymptotic limit.

  4. Efficacy of CBCT for assessment of impacted mandibular third molars: a review – based on a hierarchical model of evidence

    PubMed Central

    Wenzel, A

    2015-01-01

    A radiographic examination of mandibular third molars is meant to support the surgeon in establishing a treatment plan. For years panoramic (PAN) imaging has been the first choice method; however, where an overprojection is observed between the third molar and the mandibular canal and when specific signs suggest a close contact between the molar and the canal, CBCT may be indicated. The present review provides an evaluation of the efficacy of CBCT for assessment of mandibular third molars using a six-tiered hierarchical model by Fryback and Thornbury in 1991. Levels 1–3 include studies on low evidence levels mainly regarding the technical capabilities of a radiographic method and the diagnostic accuracy of the related images. Levels 4–6 include studies on a higher level of evidence and assess the diagnostic impact of a radiographic method on the treatment of the patient in addition to the outcome for the patient and society including cost calculations. Only very few high-evidence studies on the efficacy of CBCT for radiographic examination of mandibular third molars exist and, in conclusion, periapical or PAN examination is sufficient in most cases before removal of mandibular third molars. However, CBCT may be suggested when one or more signs for a close contact between the tooth and the canal are present in the two-dimensional image—if it is believed that CBCT will change the treatment or the treatment outcome for the patient. Further research on high-evidence levels is needed. PMID:25135317

  5. Digital Cephalometric Tracings by PRO-CEPH V3 Software for Comparative Analyses of Vertical Dimension in Edentulous Patients

    PubMed Central

    Chittaranjan, B.; Kumar, B. Arun; Taruna, M.; Kumar, M. Pavan; Reddy, M. Ramu

    2015-01-01

    Background Several methods, some physiological, some radiographical and some merely based on experience are taken upon by the practitioner to get him/her close to VDO in the edentulous patients. No single method can however claim to be the perfect answer. Lateral cephalograms have been a standard mode of determining the vertical dimensions in dentate and edentulous patients since the past. Due to unavoidable manual errors, there are chances of variations in the radiographic method too. Advancement in the digital technology has made recording jaw relations faster, simpler and more precise. Aim This study compared the vertical dimension of occlusion in edentulous patients recorded by using three different physiological methods with the aid of digital cephalometric tracings using indigenously developed PRO-CEPH V3 software. Materials and Methods For the present study a total of 50 dentulous and 25 edentulous patients were selected through inclusion and exclusion criteria. A lateral cephalometric radiograph was taken for all the 50 dentulous subjects at Maximum Intercuspation (VDO) whereas three lateral cephalometric radiographs were obtained for all edentulous patients at the VDO following three different techniques- the Niswonger’s method, Phonetics method and Swallowing threshold method. Cephalometric tracings were carried out using indigenously developed PRO-CEPH V3 software. Linear and angular measurement were made and analysed. Conclusion The indigenously developed software PRO-CEPH V3 is capable of making both the linear and angular measurement and therefore provide with relative credibility information regarding the possible VDO in the edentulous patients through cephalometric radiography. PMID:26155550

  6. Study of the areas and thicknesses of mesiobucal root canals prepared by three endodontic techniques.

    PubMed

    Constante, Isa Geralda Teixeira; Davidowicz, Harry; Barletta, Fernando Branco; de Moura, Abilio Albuquerque Maranhão

    2007-01-01

    The purpose of this study was to compare, in vitro, by means of computerized analysis of digital radiographic images, the anatomic alterations produced in the mandibular molar tooth dentinal walls of mesiobucal canals with severe curvature by three different endodontic techniques: Progressive Preparation, Staged and Serial Preparation. A selection was made of 45 extracted, human, mandibular molars, with root curvatures greater than 25 degrees. They were divided into three groups for every technique studied, which were then sub-divided into three sub-groups in accordance with the position of the curvature along the root: cervical, median or apical. After access surgery and tooth length determination, the canals were filled with 100% Barium Sulphate radiological contrast and the teeth were then radiographed with a direct digital radiography system, using a special apparatus capable of keeping the samples in the same spatial position during the different radiographic takes. After the above-mentioned endodontic techniques had been performed, the teeth were again filled with Barium sulphate and were also radiographed under the same previously mentioned conditions. The pre- and post-operative digital images were then analyzed in two computerized programs, AutoCAD 2004 and CorelDraw 10, to assess, respectively, the areas and the horizontal alterations which occurred in the internal and external walls of the root canals. The results indicated that although no significant differences among the techniques were shown in the statistical analysis, in a descriptive analysis the Progressive Preparation technique was shown to be more regular, uniform and effective.

  7. Correction of static axial alignment in children with knee varus or valgus deformities through guided growth: Does it also correct dynamic frontal plane moments during walking?

    PubMed

    Böhm, Harald; Stief, Felix; Sander, Klaus; Hösl, Matthias; Döderlein, Leonhard

    2015-09-01

    Malaligned knees are predisposed to the development and progression of unicompartmental degenerations because of the excessive load placed on one side of the knee. Therefore, guided growth in skeletally immature patients is recommended. Indication for correction of varus/valgus deformities are based on static weight bearing radiographs. However, the dynamic knee abduction moment during walking showed only a weak correlation to malalignment determined by static radiographs. Therefore, the aim of the study was to measure the effects of guided growth on the normalization of frontal plane knee joint moments during walking. 15 legs of 8 patients (11-15 years) with idiopathic axial varus or valgus malalignment were analyzed. 16 typically developed peers served as controls. Instrumented gait analysis and clinical assessment were performed the day before implantation and explantation of eight-plates. Correlation between static mechanical tibiofemoral axis angle (MAA) and dynamic frontal plane knee joint moments and their change by guided growth were performed. The changes in dynamic knee moment in the frontal plane following guided growth showed high and significant correlation to the changes in static MAA (R=0.97, p<0.001). Contrary to the correlation of the changes, there was no correlation between static and dynamic measures in both sessions. In consequence two patients that had a natural knee moment before treatment showed a more pathological one after treatment. In conclusion, the changes in the dynamic load situation during walking can be predicted from the changes in static alignment. If pre-surgical gait analysis reveals a natural load situation, despite a static varus or valgus deformity, the intervention must be critically discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. The Study of Cobb Angular Velocity in Cervical Spine during Dynamic Extension-Flexion.

    PubMed

    Ren, Dong; Hu, Zhihao; Yuan, Wen

    2016-04-01

    A kinematic study of cervical spine. The aim of the study was to confirm the interesting manifestation observed in the dynamic images of the cervical spine movement from full-extension to full-flexion. To further explore the fine motion of total process of cervical spine movement with the new concept of Cobb angular velocity (CAV). Traditionally range of motion (ROM) is used to describe the cervical spine movement from extension to flexion. It is performed with only end position radiographs. However, these radiographs fail to explain how the elaborate movement happens. The dynamic images of the cervical spine movement from full-extension to full-flexion of 12 asymptomatic subjects were collected. After transforming these dynamic images to static lateral radiographs, we overlapped C7 cervical vertebrae of each subject and divided the total process of cervical spine movement into five equal partitions. Finally, CAV values from C2/3 to C6/7 were measured and analyzed. A broken line graph was created based on the data of CAV values. A simple motion process was observed in C2/3 and C3/4 segments. The motion processes of C4/5 and C5/6 segments exhibited a more complex track of "N" and "W" than the other segments. The peak CAV values of C4/5 and C5/6 were significantly greater than the other segments. From C2/3 to C6/7, the peak CAV value appeared in sequence. The intervertebral movements of cervical spine did not take a uniform motion form when the cervical spine moved from full-extension to full-flexion. From C2/3 to C6/7, the peak CAV value appeared in order. The C4/5 and C5/6 segments exhibited more complex kinematic characteristics in sagittal movement. This leads to C4/5 and C5/6 more vulnerable to injury and degeneration. We had a hypothesis that there was a positive correlation between injury/degeneration and complexity of intervertebral movement in the view of CAV. N/A.

  9. Cellular calcium dynamics in lactation and breast cancer: From physiology to pathology

    USDA-ARS?s Scientific Manuscript database

    Breast cancer is the second leading cause of cancer mortality in women, estimated at nearly 40,000 deaths and more than 230,000 new cases diagnosed in the U.S. this year alone. One of the defining characteristics of breast cancer is the radiographic presence of microcalcifications. These palpable mi...

  10. Observer POD for radiographic testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kanzler, Daniel, E-mail: daniel.kanzler@bam.de, E-mail: uwe.ewert@bam.de, E-mail: christina.mueller@bam.de; Ewert, Uwe, E-mail: daniel.kanzler@bam.de, E-mail: uwe.ewert@bam.de, E-mail: christina.mueller@bam.de; Müller, Christina, E-mail: daniel.kanzler@bam.de, E-mail: uwe.ewert@bam.de, E-mail: christina.mueller@bam.de

    2015-03-31

    The radiographic testing (RT) is a non-destructive testing (NDT) method capable of finding volumetric and open planar defects depending on their orientation. The radiographic contrast is higher for larger penetrated length of the defect in a component. Even though, the detectability of defects does not only depend on the contrast, but also on the noise, the defect area and the geometry of the defect. The currently applied Probability of Detection (POD) approach uses a detection threshold that is only based on a constant noise level or on a constant contrast threshold. This does not reflect accurately the results of evaluationsmore » by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the lateral area and shape of the indication. This work shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data of different defect types, such as ASTM E 476 EPS plates, flat bottom holes and notches. Additional experiments with different operators confirm that the depth of a defect, the lateral area and shape of its indication contribute with different weight to the detectability of the defect if evaluated by human operators on monitors.« less

  11. Clinical and radiographic assessment of transforaminal lumbar interbody fusion using HEALOS collagen-hydroxyapatite sponge with autologous bone marrow aspirate.

    PubMed

    Carter, Jason D; Swearingen, Alan B; Chaput, Christopher D; Rahm, Mark D

    2009-06-01

    Studies have suggested that the use of bone marrow aspirate (BMA) with HEALOS (DePuy Spine, Raynham, MA), a collagen-hydroxyapatite sponge (CHS), is an effective substitute for autologous iliac crest bone graft when used in fusion procedures of the lumbar spine. To assess clinical and radiographic outcomes after implantation of BMA/CHS in patients undergoing transforaminal lumbar interbody fusion (TLIF) with posterolateral fusion (PLF). Case series radiographic outcome study. Twenty patients. Radiographs/computed tomography (CT) scans. From September 2003 to October 2004, 20 patients (22 interbody levels) were implanted with BMA/CHS via TLIF/PLF with interbody cages and posterior pedicle screws. All patients were retrospectively identified and invited for a 2-year prospective follow-up. Plain radiographs with dynamic films and CT scans were taken, and fusion was assessed in a blinded manner. Follow-up averaged 27 months (range: 24-29). Primary diagnosis included spondylolisthesis (17 patients), scoliosis with asymmetric collapse (2 patients), and postdiscectomy foraminal stenosis (1 patient). The overall fusion rate was 95% (21/22 levels, 19/20 patients). Anteriorly bridging bone was observed in 91% of the anteriorly fused levels (20/22), of which 65% (13/20) occurred through and around the cage and 35% (7/20) around the cage only. Unilateral or bilateral bridging of the posterior fusion masses was observed in 91% (20/22), with 55% occurring bilaterally (12/22). In 4 (18%) cases, bridging only occurred either posteriorly (2 cases) or anteriorly (2 cases). Complications included one deep wound infection. At the 2-year follow-up, BMA/CHS showed acceptable fusion rates in patients undergoing TLIF/PLF, and can be considered as an alternative source of graft material.

  12. Radiographic analysis of the correlation between ossification of the nuchal ligament and sagittal alignment and segmental stability of the cervical spine in patients with cervical spondylotic myelopathy.

    PubMed

    Ying, Jinwei; Teng, Honglin; Qian, Yunfan; Hu, Yingying; Wen, Tianyong; Ruan, Dike; Zhu, Minyu

    2018-01-01

    Background Ossification of the nuchal ligament (ONL) caused by chronic injury to the nuchal ligament (NL) is very common in instability-related cervical disorders. Purpose To determine possible correlations between ONL, sagittal alignment, and segmental stability of the cervical spine. Material and Methods Seventy-three patients with cervical spondylotic myelopathy (CSM) and ONL (ONL group) and 118 patients with CSM only (control group) were recruited. Radiographic data included the characteristics of ONL, sagittal alignment and segmental stability, and ossification of the posterior longitudinal ligament (OPLL). We performed comparisons in terms of radiographic parameters between the ONL and control groups. The correlations between ONL size, cervical sagittal alignment, and segmental stability were analyzed. Multivariate logistic regression was used to identify the independent risk factors of the development of ONL. Results C2-C7 sagittal vertical axis (SVA), T1 slope (T1S), T1S minus cervical lordosis (T1S-CL) on the lateral plain, angular displacement (AD), and horizontal displacement (HD) on the dynamic radiograph increased significantly in the ONL group compared with the control group. The size of ONL significantly correlated with C2-C7 SVA, T1S, AD, and HD. The incidence of ONL was higher in patients with OPLL and segmental instability. Cervical instability, sagittal malalignment, and OPLL were independent predictors of the development of ONL through multivariate analysis. Conclusion Patients with ONL are more likely to have abnormal sagittal alignment and instability of the cervical spine. Thus, increased awareness and appreciation of this often-overlooked radiographic finding is warranted during diagnosis and treatment of instability-related cervical pathologies and injuries.

  13. NDE of structural ceramics

    NASA Technical Reports Server (NTRS)

    Klima, S. J.; Vary, A.

    1986-01-01

    Radiographic, ultrasonic, scanning laser acoustic microscopy (SLAM), and thermo-acoustic microscopy techniques were used to characterize silicon nitride and silicon carbide modulus-of-rupture test specimens in various stages of fabrication. Conventional and microfocus X-ray techniques were found capable of detecting minute high density inclusions in as-received powders, green compacts, and fully densified specimens. Significant density gradients in sintered bars were observed by radiography, ultrasonic velocity, and SLAM. Ultrasonic attenuation was found sensitive to microstructural variations due to grain and void morphology and distribution. SLAM was also capable of detecting voids, inclusions and cracks in finished test bars. Consideration is given to the potential for applying thermo-acoustic microscopy techniques to green and densified ceramics. The detection probability statistics and some limitations of radiography and SLAM also are discussed.

  14. Coupled particle-in-cell and Monte Carlo transport modeling of intense radiographic sources

    NASA Astrophysics Data System (ADS)

    Rose, D. V.; Welch, D. R.; Oliver, B. V.; Clark, R. E.; Johnson, D. L.; Maenchen, J. E.; Menge, P. R.; Olson, C. L.; Rovang, D. C.

    2002-03-01

    Dose-rate calculations for intense electron-beam diodes using particle-in-cell (PIC) simulations along with Monte Carlo electron/photon transport calculations are presented. The electromagnetic PIC simulations are used to model the dynamic operation of the rod-pinch and immersed-B diodes. These simulations include algorithms for tracking electron scattering and energy loss in dense materials. The positions and momenta of photons created in these materials are recorded and separate Monte Carlo calculations are used to transport the photons to determine the dose in far-field detectors. These combined calculations are used to determine radiographer equations (dose scaling as a function of diode current and voltage) that are compared directly with measured dose rates obtained on the SABRE generator at Sandia National Laboratories.

  15. Conversion from film to image plates for transfer method neutron radiography of nuclear fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Craft, Aaron E.; Papaioannou, Glen C.; Chichester, David L.

    This paper summarizes efforts to characterize and qualify a computed radiography (CR) system for neutron radiography of irradiated nuclear fuel at Idaho National Laboratory (INL). INL has multiple programs that are actively developing, testing, and evaluating new nuclear fuels. Irradiated fuel experiments are subjected to a number of sequential post-irradiation examination techniques that provide insight into the overall behavior and performance of the fuel. One of the first and most important of these exams is neutron radiography, which provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Results from neutronmore » radiography are often the driver for subsequent examinations of the PIE program. Features of interest that can be evaluated using neutron radiography include irradiation-induced swelling, isotopic and fuel-fragment redistribution, plate deformations, and fuel fracturing. The NRAD currently uses the foil-film transfer technique with film for imaging fuel. INL is pursuing multiple efforts to advance its neutron imaging capabilities for evaluating irradiated fuel and other applications, including conversion from film to CR image plates. Neutron CR is the current state-of-the-art for neutron imaging of highly-radioactive objects. Initial neutron radiographs of various types of nuclear fuel indicate that radiographs can be obtained of comparable image quality currently obtained using film. This paper provides neutron radiographs of representative irradiated fuel pins along with neutron radiographs of standards that informed the qualification of the neutron CR system for routine use. Additionally, this paper includes evaluations of some of the CR scanner parameters and their effects on image quality.« less

  16. Can Fan-Beam Interactive Computed Tomography Accurately Predict Indirect Decompression in Minimally Invasive Spine Surgery Fusion Procedures?

    PubMed

    Janssen, Insa; Lang, Gernot; Navarro-Ramirez, Rodrigo; Jada, Ajit; Berlin, Connor; Hilis, Aaron; Zubkov, Micaella; Gandevia, Lena; Härtl, Roger

    2017-11-01

    Recently, novel mobile intraoperative fan-beam computed tomography (CT) was introduced, allowing for real-time navigation and immediate intraoperative evaluation of neural decompression in spine surgery. This study sought to investigate whether intraoperatively assessed neural decompression during minimally invasive spine surgery (MISS) has a predictive value for clinical and radiographic outcome. A retrospective study of patients undergoing intraoperative CT (iCT)-guided extreme lateral interbody fusion or transforaminal lumbar interbody fusion was conducted. 1) Preoperative, 2) intraoperative (after cage implantation, 3) postoperative, and 4) follow-up radiographic and clinical parameters obtained from radiography or CT were quantified. Thirty-four patients (41 spinal segments) were analyzed. iCT-based navigation was successfully accomplished in all patients. Radiographic parameters showed significant improvement from preoperatively to intraoperatively after cage implantation in both MISS procedures (extreme lateral interbody fusion/transforaminal lumbar interbody fusion) (P ≤ 0.05). Radiologic parameters for both MISS fusion procedures did not show significant differences to the assessed radiographic measures at follow-up (P > 0.05). Radiologic outcome values did not decrease when compared intraoperatively (after cage implantation) to latest follow-up. Intraoperative fan-beam CT is capable of assessing neural decompression intraoperatively with high accuracy, allowing for precise prediction of radiologic outcome and earliest possible feedback during MISS fusion procedures. These findings are highly valuable for routine practice and future investigations toward finding a threshold for neural decompression that translates into clinical improvement. If sufficient neural decompression has been confirmed with iCT imaging studies, additional postoperative and/or follow-up imaging studies might no longer be required if patients remain asymptomatic. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Comparison of radiographic changes after ACDF versus Bryan disc arthroplasty in single and bi-level cases

    PubMed Central

    Limson, Marc Anthony; Kim, Soo-Bum; Arbatin, Jose Joefrey F.; Chang, Kee-Young; Park, Moon-Soo; Shin, Jae-hyuk; Ju, Yeong-Su

    2009-01-01

    The object of this study is to compare radiographic outcomes of anterior cervical decompression and fusion (ACDF) versus cervical disc replacement using the Bryan Cervical Disc Prosthesis (Medtronic Sofamor Danek, Memphis, TN) in terms of range of motion (ROM), Functional spinal unit (FSU), overall sagittal alignment (C2–C7), anterior intervertebral height (AIH), posterior intervertebral height (PIH) and radiographic changes at the implanted and adjacent levels. The study consisted of 105 patients. A total of 63 Bryan disc were placed in 51 patients. A single level procedure was performed in 39 patients and a two-level procedure in the other 12. Fifty-four patients underwent ACDF, 26 single level cases and 28 double level cases. The Bryan group had a mean follow-up 19 months (12–38). Mean follow-up for the ACDF group was 20 months (12–40 months). All patients were evaluated using static and dynamic cervical spine radiographs as well as MR imaging. All patients underwent anterior cervical discectomy followed by autogenous bone graft with plate (or implantation of a cage) or the Bryan artificial disc prosthesis. Clinical evaluation included the visual analogue scale (VAS), and neck disability index (NDI). Radiographic evaluation included static and dynamic flexion-extension radiographs using the computer software (Infinitt PiviewSTAR 5051) program. ROM, disc space angle, intervertebral height were measured at the operative site and adjacent levels. FSU and overall sagittal alignment (C2–C7) were also measured pre-operatively, postoperatively and at final follow-up. Radiological change was analyzed using χ2 test (95% confidence interval). Other data were analyzed using the mixed model (SAS enterprises guide 4.1 versions). There was clinical improvement within each group in terms of VAS and NDI scores from pre-op to final follow-up but not significantly between the two groups for both single (VAS p = 0.8371, NDI p = 0.2872) and double (VAS p = 0.2938, NDI p = 0.6753) level surgeries. Overall, ROM and intervertebral height was relatively well maintained during the follow-up in the Bryan group compared to ACDF. Regardless of the number of levels operated on, significant differences were noted for overall ROM of the cervical spine (p < 0.0001) and all other levels except at the upper adjacent level for single level surgeries (p = 0.2872). Statistically significant (p < 0.0001 and p = 0.0172) differences in the trend of intervertebral height measurements between the two groups were noted at all levels except for the AIH of single level surgeries at the upper (p = 0.1264) and lower (p = 0.7598) adjacent levels as well as PIH for double level surgeries at the upper (p = 0.8363) adjacent level. Radiological change was 3.5 times more observed for the ACDF group. Clinical status of both groups, regardless of the number of levels, showed improvement. Although clinical outcomes between the two groups were not significantly different at final follow-up, radiographic parameters, namely ROM and intervertebral heights at the operated site, some adjacent levels as well as FSU and overall sagittal alignment of the cervical spine were relatively well maintained in Bryan group compared to ACDF group. We surmise that to a certain degree, the maintenance of these parameters could contribute to reduce development of adjacent level change. Noteworthy is that radiographic change was 3.5 times more observed for ACDF surgeries. A longer period of evaluation is needed, to see if all these radiographic changes will translate to symptomatic adjacent level disease. PMID:19127374

  18. The transition zone above a lumbosacral fusion.

    PubMed

    Hambly, M F; Wiltse, L L; Raghavan, N; Schneiderman, G; Koenig, C

    1998-08-15

    The clinical and radiographic effect of a lumbar or lumbosacral fusion was studied in 42 patients who had undergone a posterolateral fusion with an average follow-up of 22.6 years. To examine the long-term effects of posterolateral lumbar or lumbosacral fusion on the cephalad two motion segments (transition zone). It is commonly held that accelerated degeneration occurs in the motion segments adjacent to a fusion. Most studies are of short-term, anecdotal, uncontrolled reports that pay particular attention only to the first motion segment immediately cephalad to the fusion. Forty-two patients who had previously undergone a posterolateral lumbar or lumbosacral fusion underwent radiographic and clinical evaluation. Rate of fusion, range of motion, osteophytes, degenerative spondylolisthesis, retrolisthesis, facet arthrosis, disc ossification, dynamic instability, and disc space height were all studied and statistically compared with an age- and gender-matched control group. The patient's self-reported clinical outcome was also recorded. Degenerative changes occurred at the second level above the fused levels with a frequency equal to those occurring in the first level. There was no statistical difference between the study group and the cohort group in the presence of radiographic changes within the transition zone. In those patients undergoing fusion for degenerative processes, 75% reported a good to excellent outcome, whereas 84% of those undergoing fusion for spondylolysis or spondylolisthesis reported a good to excellent outcome. Radiographic changes occur within the transition zone cephalad to a lumbar or lumbosacral fusion. However, these changes are also seen in control subjects who have had no surgery.

  19. Plasma-Filled Rod-Pinch Diode Research on Gamble II

    DTIC Science & Technology

    2007-06-01

    by the dashed red line in Fig. 3. CaF2 thermoluminescent dosimeters ( TLDs ) located on the front surface of the rolled edge measure the dose. The...half-maximum line-spread function] and high dose [23 rad(CaF2) at 1 m] with 1-2 MeV electron energies are unique capabilities that the PFRP offers...for radiographic imaging in this electron -energy range. The source distribution has a narrow central peak that can enhance the spatial resolution

  20. Low Cost High Volume Radiographic Inspection.

    DTIC Science & Technology

    1981-01-01

    EDITION IS OBSOLETE A 81 3 30 090 NO A DISPOSITION INSTRUCTIONS SETOY THIS REPORT WHEN. IT IS NO LONGER NEED0E. DO NOT ArM IT TO THE ORIGINATOR...26159-1 7 AUTMOR(a) 4.CONTRACT OR GRANT NUMBERfA) Ned M. Lowry DAAK4-78-C-0197 Helen J. Abplanalp 3 ~5 Jon M. Taxike _____________ 9. PERFORMING...system includes capabilities for: (1) real time X-ray radiography (2) digital image enhancement, ( 3 ) remote part positioning and manipulation and (4

  1. A Large-Sample Test of a Semi-Automated Clavicle Search Engine to Assist Skeletal Identification by Radiograph Comparison.

    PubMed

    D'Alonzo, Susan S; Guyomarc'h, Pierre; Byrd, John E; Stephan, Carl N

    2017-01-01

    In 2014, a morphometric capability to search chest radiograph databases by quantified clavicle shape was published to assist skeletal identification. Here, we extend the validation tests conducted by increasing the search universe 18-fold, from 409 to 7361 individuals to determine whether there is any associated decrease in performance under these more challenging circumstances. The number of trials and analysts were also increased, respectively, from 17 to 30 skeletons, and two to four examiners. Elliptical Fourier analysis was conducted on clavicles from each skeleton by each analyst (shadowgrams trimmed from scratch in every instance) and compared to the search universe. Correctly matching individuals were found in shortlists of 10% of the sample 70% of the time. This rate is similar to, although slightly lower than, rates previously found for much smaller samples (80%). Accuracy and reliability are thereby maintained, even when the comparison system is challenged by much larger search universes. © 2016 American Academy of Forensic Sciences.

  2. Association of mechanical factors with medial knee osteoarthritis: A cross-sectional study from Matsudai Knee Osteoarthritis Survey.

    PubMed

    Omori, Go; Narumi, Kentaro; Nishino, Katsutoshi; Nawata, Atsushi; Watanabe, Hiroshi; Tanaka, Masaei; Endoh, Kazuo; Koga, Yoshio

    2016-07-01

    Knee osteoarthritis (OA) is a multifactorial disease that is affected by mechanical factors. The aim of present study was to investigate the association between multiple mechanical factors and medial knee OA in a large epidemiological cohort. Six hundred and ninety-nine subjects (323 males and 376 females), participating in the Matsudai Knee Osteoarthritis Survey 2010, were included. Twelve mechanical factors were selected and their association with the radiographic grade of knee OA, the Western Ontario and McMaster University Index (WOMAC) pain score, and the WOMAC function score was evaluated. A logistic regression analysis identified varus thrust to be associated with the radiographic grade of knee OA in males (OR: 1.876, 95% CI: 1.332-2.663) and females (2.61, 1.922-3.542), the WOMAC pain score in males (1.997, 1.463-2.672), and the WOMAC function score in females (1.449, 1.12-1.874). Quadriceps muscle strength was associated with the radiographic OA grade in males (0.605, 0.399-0.917) and females (0.636, 0.469-0.863), the WOMAC pain score in females (0.537, 0.445-0.789), and the WOMAC function score in males (0.581, 0.44-0.766). The knee flexion angle was also associated with the radiographic OA grade in males (0.344, 0.19-0.621) and females (0.121, 0.022-0.653), and the WOMAC pain score in males (0.287, 0.156-0.53) and females (0.537, 0.336-0.859). Obesity was associated with the radiographic OA grade in males (1.543, 1.041-2.287) and females (1.589, 1.176-2.146), the WOMAC pain score in female (2.017, 1.517-2.68). Femolo-tibial angle had no significant association with the radiographic knee OA grade or with the WOMAC pain and function scores. Among patients with medial knee OA, dynamic mechanical factors, such as varus thrust, quadriceps muscle strength, and range of motion were more likely to be associated with the radiographic grade of knee OA and to be the WOMAC pain and function scores, compared to static mechanical factors. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  3. A novel teaching tool using dynamic cues improves visualisation of chest lesions by naive observers

    NASA Astrophysics Data System (ADS)

    Mohamed Ali, M. A.; Toomey, R. J.; Ryan, J. T.; Cuffe, F. C.; Brennan, P. C.

    2009-02-01

    Introduction Dynamic cueing is an effective way of stimulating perception of regions of interest within radiological images. This study explores the impact of a novel teaching tool using dynamic cueing for lesion detection on plain chest radiographs. Materials and methods Observer performance studies were carried out where 36 novices examined 30 chest images in random order. Half of these contained between one and three simulated pulmonary nodules. Three groups were investigated: A (control: no teaching tool), B (retested immediately after undergoing the teaching tool) and C (retested a week after undergoing the teaching tool). The teaching tool involved dynamically displaying the same images with and without lesions. Results were compared using Receiver Operating Characteristics (ROC), sensitivity and specificity analyses. Results The second reading showed significantly greater area under the ROC curve (Az value) (p<0.0001) and higher sensitivity value (p=0.004) compared to the first reading for Group B. No differences between readings were demonstrated for groups A or C. When the magnitudes of the above changes were compared between Group B and the other two groups, greater changes in Az value for Group B were noted (B vs. A:p=0.0003, B vs. C:p=0.0005). For sensitivity, when Group B was compared to Group A, the magnitude of the change was significantly greater (p=0.0029) whereas when Group B was compared to Group C, the magnitude change demonstrated a level approaching significance (p=0.0768). Conclusions The novel teaching tool improves identification of pulmonary nodular lesions on chest radiographs in the short term.

  4. High Density Polyetherurethane Foam as a Fragmentation and Radiographic Surrogate for Cortical Bone

    PubMed Central

    Beardsley, Christina L; Heiner, Anneliese D; Brandser, Eric A; Marsh, J Lawrence; Brown, Thomas D

    2000-01-01

    Background Although one of the most important factors in predicting outcome of articular fracture, the comminution of the fracture is only subjectively assessed. To facilitate development of objective, quantitative measures of comminution phenomena, there is need for a bone fragmentation surrogate. Methods Laboratory investigation was undertaken to develop and characterize a novel synthetic material capable of emulating the fragmentation and radiographic behavior of human cortical bone. Result Screening tests performed with a drop tower apparatus identified high-density polyetherurethane foam as having suitable fragmentation properties. The material's impact behavior and its quasi-static mechanical properties are here described. Dispersal of barium sulfate (BaSO4) in the resin achieved radio-density closely resembling that of bone, without detectably altering mechanical behavior. The surrogate material's ultimate strength, elastic modulus, and quasi-static toughness are within an order of magnitude of those of mammalian cortical bone. The spectrum of comminution patterns produced by this material when impacted with varying amounts of energy is very comparable to the spectrum of bone fragment comminution seen clinically. Conclusions A novel high-density polyetherurethane foam, when subjected to impact loading, sustains comminuted fracture in a manner strikingly similar to cortical bone. Moreover, since the material also can be doped with radio-opacifier so as to closely emulate bone's radiographic signature, it opens many new possibilities for CT-based systematic study of comminution phenomena. PMID:10934621

  5. Development of an interpretive simulation tool for the proton radiography technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levy, M. C., E-mail: levymc@stanford.edu; Lawrence Livermore National Laboratory, Livermore, California 94551; Ryutov, D. D.

    2015-03-15

    Proton radiography is a useful diagnostic of high energy density (HED) plasmas under active theoretical and experimental development. In this paper, we describe a new simulation tool that interacts realistic laser-driven point-like proton sources with three dimensional electromagnetic fields of arbitrary strength and structure and synthesizes the associated high resolution proton radiograph. The present tool’s numerical approach captures all relevant physics effects, including effects related to the formation of caustics. Electromagnetic fields can be imported from particle-in-cell or hydrodynamic codes in a streamlined fashion, and a library of electromagnetic field “primitives” is also provided. This latter capability allows users tomore » add a primitive, modify the field strength, rotate a primitive, and so on, while quickly generating a high resolution radiograph at each step. In this way, our tool enables the user to deconstruct features in a radiograph and interpret them in connection to specific underlying electromagnetic field elements. We show an example application of the tool in connection to experimental observations of the Weibel instability in counterstreaming plasmas, using ∼10{sup 8} particles generated from a realistic laser-driven point-like proton source, imaging fields which cover volumes of ∼10 mm{sup 3}. Insights derived from this application show that the tool can support understanding of HED plasmas.« less

  6. Comparison of computed radiography and conventional radiography in detection of small volume pneumoperitoneum.

    PubMed

    Marolf, Angela; Blaik, Margaret; Ackerman, Norman; Watson, Elizabeth; Gibson, Nicole; Thompson, Margret

    2008-01-01

    The role of digital imaging is increasing as these systems are becoming more affordable and accessible. Advantages of computed radiography compared with conventional film/screen combinations include improved contrast resolution and postprocessing capabilities. Computed radiography's spatial resolution is inferior to conventional radiography; however, this limitation is considered clinically insignificant. This study prospectively compared digital imaging and conventional radiography in detecting small volume pneumoperitoneum. Twenty cadaver dogs (15-30 kg) were injected with 0.25, 0.25, and 0.5 ml for 1 ml total of air intra-abdominally, and radiographed sequentially using computed and conventional radiographic technologies. Three radiologists independently evaluated the images, and receiver operating curve (ROC) analysis compared the two imaging modalities. There was no statistical difference between computed and conventional radiography in detecting free abdominal air, but overall computed radiography was relatively more sensitive based on ROC analysis. Computed radiographic images consistently and significantly demonstrated a minimal amount of 0.5 ml of free air based on ROC analysis. However, no minimal air amount was consistently or significantly detected with conventional film. Readers were more likely to detect free air on lateral computed images than the other projections, with no significant increased sensitivity between film/screen projections. Further studies are indicated to determine the differences or lack thereof between various digital imaging systems and conventional film/screen systems.

  7. Malignant transformation of a unicameral bone cyst in a cat.

    PubMed

    Berger, Björn; Brühschwein, Andreas; Eddicks, Lina; Meyer-Lindenberg, Andrea

    2016-04-01

    A unicameral bone cyst in the proximal humerus of a 3-year-old Norwegian forest cat was diagnosed by dynamic contrast-enhanced magnetic resonance imaging, surgical exploration, and histopathology. Surgical curettage and incorporation of bone cement led to full recovery. An osteosarcoma developed at the surgical site 17 months later. Thoracic radiographs showed pulmonary lesions consistent with metastasis.

  8. Malignant transformation of a unicameral bone cyst in a cat

    PubMed Central

    Berger, Björn; Brühschwein, Andreas; Eddicks, Lina; Meyer-Lindenberg, Andrea

    2016-01-01

    A unicameral bone cyst in the proximal humerus of a 3-year-old Norwegian forest cat was diagnosed by dynamic contrast-enhanced magnetic resonance imaging, surgical exploration, and histopathology. Surgical curettage and incorporation of bone cement led to full recovery. An osteosarcoma developed at the surgical site 17 months later. Thoracic radiographs showed pulmonary lesions consistent with metastasis. PMID:27041754

  9. Fusion Rate and Clinical Outcomes in Two-Level Posterior Lumbar Interbody Fusion.

    PubMed

    Aono, Hiroyuki; Takenaka, Shota; Nagamoto, Yukitaka; Tobimatsu, Hidekazu; Yamashita, Tomoya; Furuya, Masayuki; Iwasaki, Motoki

    2018-04-01

    Posterior lumbar interbody fusion (PLIF) has become a general surgical method for degenerative lumbar diseases. Although many reports have focused on single-level PLIF, few have focused on 2-level PLIF, and no report has covered the fusion status of 2-level PLIF. The purpose of this study is to investigate clinical outcomes and fusion for 2-level PLIF by using a combination of dynamic radiographs and multiplanar-reconstruction computed tomography scans. This study consisted of 48 consecutive patients who underwent 2-level PLIF for degenerative lumbar diseases. We assessed surgery duration, estimated blood loss, complications, clinical outcomes as measured by the Japanese Orthopaedic Association score, lumbar sagittal alignment as measured on standing lateral radiographs, and fusion status as measured by dynamic radiographs and multiplanar-reconstruction computed tomography. Patients were examined at a follow-up point of 4.8 ± 2.2 years after surgery. Thirty-eight patients who did not undergo lumbosacral fusion comprised the lumbolumbar group, and 10 patients who underwent lumbosacral fusion comprised the lumbosacral group. The mean Japanese Orthopaedic Association score improved from 12.1 to 22.4 points by the final follow-up examination. Sagittal alignment also was improved. All patients had fusion in the cranial level. Seven patients had nonunion in the caudal level, and the lumbosacral group (40%) had a significantly poorer fusion rate than the lumbolumbar group (97%) did. Surgical outcomes of 2-level PLIF were satisfactory. The fusion rate at both levels was 85%. All nonunion was observed at the caudal level and concentrated at L5-S level in L4-5-S PLIF. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Symptomatic relevance of intravertebral cleft in patients with osteoporotic vertebral fracture.

    PubMed

    Kawaguchi, Satoshi; Horigome, Keiko; Yajima, Hideki; Oda, Takashi; Kii, Yuichiro; Ida, Kazunori; Yoshimoto, Mitsunori; Iba, Kousuke; Takebayashi, Tsuneo; Yamashita, Toshihiko

    2010-08-01

    The present study was designed to determine clinical and radiographic characteristics of unhealed osteoporotic vertebral fractures (OVFs) and the role of fracture mobility and an intravertebral cleft in the regulation of pain symptoms in patients with an OVF. Patients who had persistent low-back pain for 3 months or longer and a collapsed thoracic or lumbar vertebra that had an intervertebral cleft and abnormal mobility were referred to as having unhealed OVFs. Twenty-four patients with an unhealed OVF and 30 patients with an acute OVF were compared with regard to several clinical and radiographic features including the presence of an intravertebral fluid sign. Subsequently, the extent of dynamic mobility of the fractured vertebra was analyzed for correlation with the patients' age, duration of symptoms, back pain visual analog scale (VAS) score, and performance status. Finally, in cases of unhealed OVFs, the subgroup of patients with positive fluid signs was compared with the subgroup of patients with negative fluid signs. Patients with an unhealed OVF were more likely to have a crush-type fracture, shorter vertebral height of the fractured vertebra, and a fracture with a positive fluid sign than those with an acute OVF. The extent of dynamic mobility of the vertebra correlated significantly with the VAS score in patients with an unhealed OVF. In addition, a significant correlation with the extent of dynamic vertebral mobility with performance status was seen in patients with an unhealed OVF and those with an acute OVF. Of the 24 patients with an unhealed OVF, 14 had a positive fluid sign in the affected vertebra. Patients with a positive fluid sign exhibited a statistically significantly greater extent of dynamic vertebral mobility, a higher VAS score, a higher performance status grade, and a greater likelihood of having a crush-type fracture than those with a negative fluid sign. All but 1 patient with an unhealed OVF and a positive fluid sign had an Eastern Cooperative Oncology Group Performance Status Grade 3 or 4 (bedridden most or all of the time). In sharp contrast, all 10 patients with an unhealed OVF and a negative fluid sign were Grade 1 or 2. Unhealed OVFs form a group of fractures that are distinct from acute OVFs regarding radiographic morphometry and contents of the intravertebral cleft. Dynamic vertebral mobility serves as a primal pain determinant in patients with an unhealed OVF and potentially in those with an acute OVF. Fluid accumulation in the intravertebral cleft of unhealed OVFs likely reflects long-term bedridden positioning of the patients in daily activity.

  11. Reducing the spatial resolution range of neutron radiographs cast by thick objects

    NASA Astrophysics Data System (ADS)

    Almeida, G. L.; Silvani, M. I.; Souza, E. S.; Lopes, R. T.

    2017-11-01

    The quality of a neutron radiograph is strongly dependent upon the features of the acquisition system. Most of them, such as detector resolution, electronic noise and statistical fluctuation can hardly be improved. Yet, a main parameter ruling the image spatial resolution, namely the L/D ratio of the system can be increased simply by lengthening the source-detector clearance. Such an option eventually may not be feasible due to neutron flux decreasing or engineering constraints. Under this circumstance, a radiograph improvement is only possible by some kind of after-acquisition procedure capable to retrieve, at least partially, the information concealed by the degradation process. Since the spoiling agent tied to the L/D has a systematic character, its impact can be reduced by an unfolding procedure such as Richardson-Lucy algorithm. However, that agent should be fully characterized and furnished to the algorithm as a Point Spread Function - PSF unfolding function. A main drawback of unfolding algorithms like Richardson-Lucy is that the PSF should be fixed, i.e., it assumes a certain constant image spatial resolution, rather than a variable one as actually occurs for thick objects. This work presents a methodology to minimize this difficulty by making all planes of the inspected object to cast a resolution within the shorter gap comprised between the object central plane and the detector. The image can then be unfolded with a lower resolution within a tighter range, yielding a better quality. The process is performed with two radiographs, where one of them is acquired with the object turned by 180° on its vertical axis with regard to the other. After a mirroring of one of them about its vertical axis, the images are added. As the resolution increases linearly with the object-detector gap, it would remain always lower than that of the central one. Therefore, the overall resolution of the composite radiograph is enhanced. A further improvement can then be achieved through an efficient unfolding since the object has been virtually shrunk along the neutron path.

  12. Swallowing dynamics status post caustic ingestion in a pediatric patient: A multidisciplinary case report.

    PubMed

    Miller, Claire Kane; Rutter, Michael J; von Allmen, Daniel; Stoops, Marilyn; Putnam, Philip; Stevens, Luann; Willging, J Paul

    2016-07-01

    A case report of a 10 year old male illustrates the effect of damage to the tongue base, hypopharynx, cricopharyngeus, and esophagus on the sensory and motor components of the swallowing mechanism. The characteristics of the dysphagia were manifested clinically, radiographically, and endoscopically. A myectomy was required to restore functional swallowing as scar tissue formation in the cricopharyngeus severely interfered with the dynamic components of swallowing. A collaborative approach facilitated communication and effective treatment planning; the multidisciplinary components in the management of this case are discussed. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. A prospective randomized multicenter trial comparing clinical outcomes of patients treated surgically with a static or dynamic implant for acute ankle syndesmosis rupture.

    PubMed

    Laflamme, Mélissa; Belzile, Etienne L; Bédard, Luc; van den Bekerom, Michel P J; Glazebrook, Mark; Pelet, Stéphane

    2015-05-01

    To compare the clinical and radiographic outcome after stabilization of an acute syndesmosis rupture with either a static implant (a 3.5-mm metallic screw through 4 cortices) or a dynamic device (TightRope; Arthrex). Multicenter randomized double-blind controlled trial. Study realized in 5 trauma centers (2 level 1 and 3 level 2) in 2 countries. Seventy subjects admitted for an acute ankle syndesmosis rupture entered the study and were randomized into 2 groups (dynamic fixation = 34 and static fixation = 36). The 2 groups were similar regarding demographic, social, and surgical data. Sixty-five patients (dynamic = 33 and static = 32) completed the study and were available for analysis. Syndesmosis fixation in the static group was realized with a 4 cortices 3.5-mm cortical screw (Synthes) and in the dynamic group with 1 TightRope (Arthrex). Standardized rehabilitation process for the 2 groups: no weight bearing in a cast for 6 weeks and then rehabilitation without protection. Olerud-Molander score. Subjects with dynamic fixation achieved better clinical performances as described with the Olerud-Molander scores at 3 (68.8 vs. 60.2, P = 0.067), 6 (84.2 vs. 76.8, P = 0.082), and 12 months (93.3 vs. 87.6, P = 0.046). We also observed higher American Orthopaedic Foot and Ankle Society scores at 3 months (78.6 vs. 70.6, P = 0.016), but these were not significant at 6 (87.1 vs. 83.8, P = 0.26) or 12 months (93.1 vs. 89.9, P = 0.26). Implant failure was higher in the screw group (36.1% vs. 0%, P < 0.05). Loss of reduction was observed in 4 cases in the static screw group (11.1% vs. 0%, P = 0.06). Dynamic fixation of acute ankle syndesmosis rupture with a dynamic device seems to result in better clinical and radiographic outcomes. The implant offers adequate syndesmotic stabilization without failure or loss of reduction, and the reoperation rate is significantly lower than with conventional screw fixation. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  14. Differential Equation Models for Sharp Threshold Dynamics

    DTIC Science & Technology

    2012-08-01

    dynamics, and the Lanchester model of armed conflict, where the loss of a key capability drastically changes dynamics. We derive and demonstrate a step...dynamics using differential equations. 15. SUBJECT TERMS Differential Equations, Markov Population Process, S-I-R Epidemic, Lanchester Model 16...infection, where a detection event drastically changes dynamics, and the Lanchester model of armed conflict, where the loss of a key capability

  15. Medial Longitudinal Arch Angle Presents Significant Differences Between Foot Types: A Biplane Fluoroscopy Study.

    PubMed

    Balsdon, Megan E R; Bushey, Kristen M; Dombroski, Colin E; LeBel, Marie-Eve; Jenkyn, Thomas R

    2016-10-01

    The structure of the medial longitudinal arch (MLA) affects the foot's overall function and its ability to dissipate plantar pressure forces. Previous research on the MLA includes measuring the calcaneal-first metatarsal angle using a static sagittal plane radiograph, a dynamic height-to-length ratio using marker clusters with a multisegment foot model, and a contained angle using single point markers with a multisegment foot model. The objective of this study was to use biplane fluoroscopy to measure a contained MLA angle between foot types: pes planus (low arch), pes cavus (high arch), and normal arch. Fifteen participants completed the study, five from each foot type. Markerless fluoroscopic radiostereometric analysis (fRSA) was used with a three-dimensional model of the foot bones and manually matching those bones to a pair of two-dimensional radiographic images during midstance of gait. Statistically significant differences were found between barefoot arch angles of the normal and pes cavus foot types (p = 0.036), as well as between the pes cavus and pes planus foot types (p = 0.004). Dynamic walking also resulted in a statistically significant finding compared to the static standing trials (p = 0.014). These results support the classification of individuals following a physical assessment by a foot specialist for those with pes cavus and planus foot types. The differences between static and dynamic kinematic measurements were also supported using this novel method.

  16. Transarticular facet screw stabilization and dorsal laminectomy in 26 dogs with degenerative lumbosacral stenosis with instability.

    PubMed

    Hankin, Elyshia J; Jerram, Richard M; Walker, Alexander M; King, Michael D; Warman, Christopher G A

    2012-07-01

    To describe outcome after transarticular facet screw stabilization and dorsal laminectomy for treatment of dynamic degenerative lumbosacral stenosis (DLS) in 26 dogs. Retrospective case series. Dogs (n = 26) with dynamic DLS. Medical records (2004-2009) of dogs treated with transarticular facet screw stabilization and dorsal laminectomy were reviewed. Dogs (n = 26) were available for immediate postoperative follow-up, 21 dogs at 6 weeks, and 15 at greater than 6 months. Dogs were evaluated by radiographic assessment and owner questionnaire. Lumbosacral (LS) intervertebral disc (IVD) spaces were measured on pre and postoperative 6-week and 6-month radiographs. In 23 dogs, improvement in clinical signs occurred within 7 days of surgery. Overall postsurgical complication rate directly related to the surgical procedure was 15.4%. LS IVD space measurements taken immediately postoperatively, at 6 weeks, and ≥ 6 months were all significantly increased compared with preoperative measurements. All working dogs (4) returned to full work within 14 months. Most owners (85%) reported their dog was ambulating normally at 6 months with no perceptible lameness during normal activity. All owners perceived their dog's ability to walk, run, and jump after surgery to be improved. Transarticular facet screw stabilization and dorsal laminectomy maintains distraction of the LS IVD space for medium-to-large breed dogs with dynamic DLS with a high degree of owner satisfaction, and is comparable to other reported surgical techniques for DLS. © Copyright 2012 by The American College of Veterinary Surgeons.

  17. Unique Testing Capabilities of the NASA Langley Transonic Dynamics Tunnel, an Exercise in Aeroelastic Scaling

    NASA Technical Reports Server (NTRS)

    Ivanco, Thomas G.

    2013-01-01

    NASA Langley Research Center's Transonic Dynamics Tunnel (TDT) is the world's most capable aeroelastic test facility. Its large size, transonic speed range, variable pressure capability, and use of either air or R-134a heavy gas as a test medium enable unparalleled manipulation of flow-dependent scaling quantities. Matching these scaling quantities enables dynamic similitude of a full-scale vehicle with a sub-scale model, a requirement for proper characterization of any dynamic phenomenon, and many static elastic phenomena. Select scaling parameters are presented in order to quantify the scaling advantages of TDT and the consequence of testing in other facilities. In addition to dynamic testing, the TDT is uniquely well-suited for high risk testing or for those tests that require unusual model mount or support systems. Examples of recently conducted dynamic tests requiring unusual model support are presented. In addition to its unique dynamic test capabilities, the TDT is also evaluated in its capability to conduct aerodynamic performance tests as a result of its flow quality. Results of flow quality studies and a comparison to a many other transonic facilities are presented. Finally, the ability of the TDT to support future NASA research thrusts and likely vehicle designs is discussed.

  18. Comparisons of Kinematics and Dynamics Simulation Software Tools

    NASA Technical Reports Server (NTRS)

    Shiue, Yeu-Sheng Paul

    2002-01-01

    Kinematic and dynamic analyses for moving bodies are essential to system engineers and designers in the process of design and validations. 3D visualization and motion simulation plus finite element analysis (FEA) give engineers a better way to present ideas and results. Marshall Space Flight Center (MSFC) system engineering researchers are currently using IGRIP from DELMIA Inc. as a kinematic simulation tool for discrete bodies motion simulations. Although IGRIP is an excellent tool for kinematic simulation with some dynamic analysis capabilities in robotic control, explorations of other alternatives with more powerful dynamic analysis and FEA capabilities are necessary. Kinematics analysis will only examine the displacement, velocity, and acceleration of the mechanism without considering effects from masses of components. With dynamic analysis and FEA, effects such as the forces or torques at the joint due to mass and inertia of components can be identified. With keen market competition, ALGOR Mechanical Event Simulation (MES), MSC visualNastran 4D, Unigraphics Motion+, and Pro/MECHANICA were chosen for explorations. In this study, comparisons between software tools were presented in terms of following categories: graphical user interface (GUI), import capability, tutorial availability, ease of use, kinematic simulation capability, dynamic simulation capability, FEA capability, graphical output, technical support, and cost. Propulsion Test Article (PTA) with Fastrac engine model exported from IGRIP and an office chair mechanism were used as examples for simulations.

  19. Implementing a Loosely Coupled Fluid Structure Interaction Finite Element Model in PHASTA

    NASA Astrophysics Data System (ADS)

    Pope, David

    Fluid Structure Interaction problems are an important multi-physics phenomenon in the design of aerospace vehicles and other engineering applications. A variety of computational fluid dynamics solvers capable of resolving the fluid dynamics exist. PHASTA is one such computational fluid dynamics solver. Enhancing the capability of PHASTA to resolve Fluid-Structure Interaction first requires implementing a structural dynamics solver. The implementation also requires a correction of the mesh used to solve the fluid equations to account for the deformation of the structure. This results in mesh motion and causes the need for an Arbitrary Lagrangian-Eulerian modification to the fluid dynamics equations currently implemented in PHASTA. With the implementation of both structural dynamics physics, mesh correction, and the Arbitrary Lagrangian-Eulerian modification of the fluid dynamics equations, PHASTA is made capable of solving Fluid-Structure Interaction problems.

  20. Augmented reality environment for temporomandibular joint motion analysis.

    PubMed

    Wagner, A; Ploder, O; Zuniga, J; Undt, G; Ewers, R

    1996-01-01

    The principles of interventional video tomography were applied for the real-time visualization of temporomandibular joint movements in an augmented reality environment. Anatomic structures were extracted in three dimensions from planar cephalometric radiographic images. The live-image fusion of these graphic anatomic structures with real-time position data of the mandible and the articular fossa was performed with a see-through, head-mounted display and an electromagnetic tracking system. The dynamic fusion of radiographic images of the temporomandibular joint to anatomic temporomandibular joint structures in motion created a new modality for temporomandibular joint motion analysis. The advantages of the method are its ability to accurately examine the motion of the temporomandibular joint in three dimensions without restraining the subject and its ability to simultaneously determine the relationship of the bony temporomandibular joint and supporting structures (ie, occlusion, muscle function, etc) during movement before and after treatment.

  1. Development and validation of a quantitative method to assess pedicle screw loosening in posterior spine instrumentation on plain radiographs.

    PubMed

    Aghayev, Emin; Zullig, Nicolas; Diel, Peter; Dietrich, Daniel; Benneker, Lorin M

    2014-03-01

    Currently, the diagnosis of pedicle screw (PS) loosening is based on a subjectively assessed halo sign, that is, a radiolucent line around the implant wider than 1 mm in plain radiographs. We aimed at development and validation of a quantitative method to diagnose PS loosening on radiographs. Between 11/2004 and 1/2010 36 consecutive patients treated with thoraco-lumbar spine fusion with PS instrumentation without PS loosening were compared with 37 other patients who developed a clinically manifesting PS loosening. Three different angles were measured and compared regarding their capability to discriminate the loosened PS over the postoperative course. The inter-observer invariance was tested and a receiver operating characteristics curve analysis was performed. The angle measured between the PS axis and the cranial endplate was significantly different between the early and all later postoperative images. The Spearman correlation coefficient for the measurements of two observers at each postoperative time point ranged between 0.89 at 2 weeks to 0.94 at 2 months and 1 year postoperative. The angle change of 1.9° between immediate postoperative and 6-month postoperative was 75% sensitive and 89% specific for the identification of loosened screws (AUC = 0.82). The angle between the PS axis and the cranial endplate showed good ability to change in PS loosening. A change of this angle of at least 2° had a relatively high sensitivity and specificity to diagnose screw loosening.

  2. Control system of mobile radiographic complex to study equations of state of substances

    NASA Astrophysics Data System (ADS)

    Belov, O. V.; Valekzhanin, R. V.; Kustov, D. V.; Shamro, O. A.; Sharov, T. V.

    2017-05-01

    A source of x-ray radiation is one of the tools to study equations of state of substances in dynamics. The mobile radiographic bench based on BIM-1500 [1] was developed in RFNC-VNIIEF to increase output parameters of the x-ray radiation source. From automated control system side, BIM-1500 is a set of six high-voltage generators based on the capacitive energy storage, technological equipment, and elements of a blocking system. This paper considers automated control system of the mobile radiographic bench MCA BIM 1500. It consists of six high-voltage generator control circuits, synchronization subsystem, and block subsystem. The object of control has some peculiarities: high level of electromagnetic noise, remoteness of the control panel from the object of control. In connection with this, the coupling devices are arranged closer to the object of control and performed in the form of a set of galvanically insulated control units, which are combined into a net. The operator runs MCA BIM using the operator’s screens on PC or by means of manual control on the equipment in the mode of debugging. The control software provides performance of the experiment in automatic regime in accordance with preset settings. The operator can stop the experiment at the stage of charging the capacitive storage.

  3. Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, G. N.; Izumi, N.; Landen, O. L.

    2016-08-03

    Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments, and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro channel plate) to provide gating and high DQE at the 40–200keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Here, experiments were performed atmore » energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.« less

  4. Image analysis algorithms for the advanced radiographic capability (ARC) grating tilt sensor at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Roberts, Randy S.; Bliss, Erlan S.; Rushford, Michael C.; Halpin, John M.; Awwal, Abdul A. S.; Leach, Richard R.

    2014-09-01

    The Advance Radiographic Capability (ARC) at the National Ignition Facility (NIF) is a laser system designed to produce a sequence of short pulses used to backlight imploding fuel capsules. Laser pulses from a short-pulse oscillator are dispersed in wavelength into long, low-power pulses, injected in the NIF main laser for amplification, and then compressed into high-power pulses before being directed into the NIF target chamber. In the target chamber, the laser pulses hit targets which produce x-rays used to backlight imploding fuel capsules. Compression of the ARC laser pulses is accomplished with a set of precision-surveyed optical gratings mounted inside of vacuum vessels. The tilt of each grating is monitored by a measurement system consisting of a laser diode, camera and crosshair, all mounted in a pedestal outside of the vacuum vessel, and a mirror mounted on the back of a grating inside the vacuum vessel. The crosshair is mounted in front of the camera, and a diffraction pattern is formed when illuminated with the laser diode beam reflected from the mirror. This diffraction pattern contains information related to relative movements between the grating and the pedestal. Image analysis algorithms have been developed to determine the relative movements between the gratings and pedestal. In the paper we elaborate on features in the diffraction pattern, and describe the image analysis algorithms used to monitor grating tilt changes. Experimental results are provided which indicate the high degree of sensitivity provided by the tilt sensor and image analysis algorithms.

  5. Survey of needs and capabilities for wind tunnel testing of dynamic stability of aircraft at high angles of attack

    NASA Technical Reports Server (NTRS)

    Orlik-Ruckemann, K. J.

    1973-01-01

    A survey was conducted relative to future requirements for dynamic stability information for such aerospace vehicles as the space shuttle and advanced high performance military aircraft. High-angle-of-attack and high-Reynolds number conditions were emphasized. A review was made of the wind-tunnel capabilities in North America for measuring dynamic stability derivatives, revealing an almost total lack of capabilities that could satisfy these requirements. Recommendations are made regarding equipment that should be constructed to remedy this situation. A description is given of some of the more advanced existing capabilities, which can be used to at least partly satisfy immediate demands.

  6. Ergonomic strategies to improve radiographers' posture during mammography activities.

    PubMed

    Cernean, Nicolai; Serranheira, Florentino; Gonçalves, Pedro; Sá Dos Reis, Cláudia

    2017-08-01

    To identify alternatives for radiographers' postures while performing mammography that can contribute to reduce the risk of work-related musculoskeletal disorders (WRMSDs). Radiographers' postures to positioning craniocaudal (CC) and mediolateral oblique (MLO) views were simulated without any intervention for three scenarios: radiographer/patient with similar statures, radiographer smaller than patient and radiographer taller than patient. Actions were taken to modify the postures: seated radiographer; patient on a step; seated patient; radiographer on a step. All the postures were analysed using kinovea 0.8.15 software and the angles were measured twice and classified according to European standard EN1005-4: 2005. The non-acceptable angles were measured mainly during MLO positioning when radiographer was taller than the patient: 139° and 120° for arm-flexion and abduction, 72° for trunk and -24° for head/neck-flexion. The introduction of alternative postures (radiographer seated), allowed improvements in posture (60° and 99° for arm flexion and abduction, 14° for trunk and 0° for head/neck flexion), being classified as acceptable. The alternative postures simulated have the potential to reduce the risk of developing WRMSDs when radiographers and patients have different statures. • Radiographers' postures in mammography can contribute to work-related musculoskeletal disorders • Non-acceptable posture was identified for MLO breast positioning (radiographer taller than patient) • Adapting posture to patient biotype reduces the WRMSD risk for radiographers.

  7. Radiographic cup anteversion measurement corrected from pelvic tilt.

    PubMed

    Wang, Liao; Thoreson, Andrew R; Trousdale, Robert T; Morrey, Bernard F; Dai, Kerong; An, Kai-Nan

    2017-11-01

    The purpose of this study was to develop a novel technique to improve the accuracy of radiographic cup anteversion measurement by correcting the influence of pelvic tilt. Ninety virtual total hip arthroplasties were simulated from computed tomography data of 6 patients with 15 predetermined cup orientations. For each simulated implantation, anteroposterior (AP) virtual pelvic radiographs were generated for 11 predetermined pelvic tilts. A linear regression model was created to capture the relationship between radiographic cup anteversion angle error measured on AP pelvic radiographs and pelvic tilt. Overall, nine hundred and ninety virtual AP pelvic radiographs were measured, and 90 linear regression models were created. Pearson's correlation analyses confirmed a strong correlation between the errors of conventional radiographic cup anteversion angle measured on AP pelvic radiographs and the magnitude of pelvic tilt (P < 0.001). The mean of 90 slopes and y-intercepts of the regression lines were -0.8 and -2.5°, which were applied as the general correction parameters for the proposed tool to correct conventional cup anteversion angle from the influence of pelvic tilt. The current method proposes to measure the pelvic tilt on a lateral radiograph, and to use it as a correction for the radiographic cup anteversion measurement on an AP pelvic radiograph. Thus, both AP and lateral pelvic radiographs are required for the measurement of pelvic posture-integrated cup anteversion. Compared with conventional radiographic cup anteversion, the errors of pelvic posture-integrated radiographic cup anteversion were reduced from 10.03 (SD = 5.13) degrees to 2.53 (SD = 1.33) degrees. Pelvic posture-integrated cup anteversion measurement improves the accuracy of radiographic cup anteversion measurement, which shows the potential of further clarifying the etiology of postoperative instability based on planar radiographs. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Errors in radiographic interpretation made by veterinary students.

    PubMed

    Lamb, C R; Pfeiffer, D U; Mantis, P

    2007-01-01

    As a means of identifying student weaknesses in radiographic interpretation that could be used as foci for teaching, a cohort of 96 students joining the final-year radiology rotation were randomly allocated to one of three radiographic interpretation quizzes, each based on radiographs of small-animal patients together with the signalment and a brief, relevant history. Students' quiz scores were analyzed by multiple logistic regression, using an outcome variable with the score for each item as numerator and maximum possible mark as denominator. Students' median quiz score was 49% of the maximum (range 23-80%). Students were more likely to gain a mark for items based on abnormal radiographs than for those based on normal radiographs (odds ratio 3.4, p < 0.001). Skeletal radiographs were associated with lower scores (OR 0.75, p = 0.03). The fewest marks were awarded for interpretation of a radiograph of a normal canine stifle and interpretation of a radiograph of a normal canine pelvis; these items were misinterpreted as abnormal by 86% and 80% of the students, respectively. Students' tendency to over-interpret normal radiographs may reflect a lack of knowledge of radiographic anatomy or an unrealistically high expectation that the radiographs are abnormal.

  9. High-Energy Neutron Imaging Development at LLNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, J M; Rusnak, B; Shen, S

    2005-02-16

    We are proceeding with the development of a high-energy (10 MeV) neutron imaging system for use as an inspection tool in nuclear stockpile stewardship applications. Our goal is to develop and deploy an imaging system capable of detecting cubic-mm-scale voids, cracks or other significant structural defects in heavily-shielded low-Z materials within nuclear device components. The final production-line system will be relatively compact (suitable for use in existing facilities within the DOE complex) and capable of acquiring both radiographic and tomographic (CT) images. In this report, we will review our recent programmatic accomplishments, focusing primarily on progress made in FY04. Themore » design status of the high-intensity, accelerator-driven neutron source and large-format imaging detector associated with the system will be discussed and results from a recent high-energy neutron imaging experiment conducted at the Ohio University Accelerator Laboratory (OUAL) will also be presented.« less

  10. High-energy (>70 keV) x-ray conversion efficiency measurement on the ARC laser at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Chen, Hui; Hermann, M. R.; Kalantar, D. H.; Martinez, D. A.; Di Nicola, P.; Tommasini, R.; Landen, O. L.; Alessi, D.; Bowers, M.; Browning, D.; Brunton, G.; Budge, T.; Crane, J.; Di Nicola, J.-M.; Döppner, T.; Dixit, S.; Erbert, G.; Fishler, B.; Halpin, J.; Hamamoto, M.; Heebner, J.; Hernandez, V. J.; Hohenberger, M.; Homoelle, D.; Honig, J.; Hsing, W.; Izumi, N.; Khan, S.; LaFortune, K.; Lawson, J.; Nagel, S. R.; Negres, R. A.; Novikova, L.; Orth, C.; Pelz, L.; Prantil, M.; Rushford, M.; Shaw, M.; Sherlock, M.; Sigurdsson, R.; Wegner, P.; Widmayer, C.; Williams, G. J.; Williams, W.; Whitman, P.; Yang, S.

    2017-03-01

    The Advanced Radiographic Capability (ARC) laser system at the National Ignition Facility (NIF) is designed to ultimately provide eight beamlets with a pulse duration adjustable from 1 to 30 ps, and energies up to 1.5 kJ per beamlet. Currently, four beamlets have been commissioned. In the first set of 6 commissioning target experiments, the individual beamlets were fired onto gold foil targets with energy up to 1 kJ per beamlet at 20-30 ps pulse length. The x-ray energy distribution and pulse duration were measured, yielding energy conversion efficiencies of 4-9 × 10-4 for x-rays with energies greater than 70 keV. With greater than 3 J of such x-rays, ARC provides a high-precision x-ray backlighting capability for upcoming inertial confinement fusion and high-energy-density physics experiments on NIF.

  11. Radiographic Measurement of Displacement in Acetabular Fractures: A Systematic Review of the Literature.

    PubMed

    Dodd, Andrew; Osterhoff, Georg; Guy, Pierre; Lefaivre, Kelly A

    2016-06-01

    To report methods of measurement of radiographic displacement and radiographic outcomes in acetabular fractures described in the literature. A systematic review of the English literature was performed using EMBASE and Medline in August 2014. Inclusion criteria were studies of operatively treated acetabular fractures in adults with acute (<6 weeks) open reduction and internal fixation that reported radiographic outcomes. Exclusion criteria included case series with <10 patients, fractures managed >6 weeks from injury, acute total hip arthroplasty, periprosthetic fractures, time frame of radiographic outcomes not stated, missing radiographic outcome data, and non-English language articles. Basic information collected included journal, author, year published, number of fractures, and fracture types. Specific data collected included radiographic outcome data, method of measuring radiographic displacement, and methods of interpreting or categorizing radiographic outcomes. The number of reproducible radiographic measurement techniques (2/64) and previously described radiographic interpretation methods (4) were recorded. One radiographic reduction grading criterion (Matta) was used nearly universally in articles that used previously described criteria. Overall, 70% of articles using this criteria documented anatomic reductions. The current standard of measuring radiographic displacement in publications dealing with acetabulum fractures almost universally lacks basic description, making further scientific rigor, such as testing reproducibility, impossible. Further work is necessary to standardize radiographic measurement techniques, test their reproducibility, and qualify their validity or determine which measurements are important to clinical outcomes. Diagnostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  12. Usefulness of intraoperative radiographs in reducing errors of cup placement and leg length during total hip arthroplasty.

    PubMed

    Wind, Michael A; Morrison, J Craig; Christie, Michael J

    2013-11-01

    Traditional methods of component placement during total hip arthroplasty (THA) can lead to errors in cup abduction angle and leg length. Intraoperative radiographs were used to assess and correct errors during surgery in a consecutive series of 278 THAs performed by a single surgeon. After exclusions, 262 cases were available for cup abduction angle assessment and 224 for leg length discrepancy (LLD) assessment. Components were initially placed in a position determined as appropriate by the surgeon. Intraoperative radiographs were taken and appropriate corrections made. Postoperative radiographs were assessed at 6 weeks. Mean abduction angle on intraoperative radiographs was 39.6°±5.9° versus 38.6°±4.1° on postoperative radiographs. Thirty-eight cups were outside the target abduction range on intraoperative radiographs versus 4 on postoperative radiographs. Mean LLD was 3.7 mm ± 3.6 mm on intraoperative radiographs and 2.5 mm ± 2.7 mm on postoperative radiographs. Use of intraoperative radiographs is a valid, useful technique for minimizing errors in THA.

  13. Perceptibility curve test for digital radiographs before and after correction for attenuation and correction for attenuation and visual response.

    PubMed

    Li, G; Welander, U; Yoshiura, K; Shi, X-Q; McDavid, W D

    2003-11-01

    Two digital image processing methods, correction for X-ray attenuation and correction for attenuation and visual response, have been developed. The aim of the present study was to compare digital radiographs before and after correction for attenuation and correction for attenuation and visual response by means of a perceptibility curve test. Radiographs were exposed of an aluminium test object containing holes ranging from 0.03 mm to 0.30 mm with increments of 0.03 mm. Fourteen radiographs were exposed with the Dixi system (Planmeca Oy, Helsinki, Finland) and twelve radiographs were exposed with the F1 iOX system (Fimet Oy, Monninkylä, Finland) from low to high exposures covering the full exposure ranges of the systems. Radiographs obtained from the Dixi and F1 iOX systems were 12 bit and 8 bit images, respectively. Original radiographs were then processed for correction for attenuation and correction for attenuation and visual response. Thus, two series of radiographs were created. Ten viewers evaluated all the radiographs in the same random order under the same viewing conditions. The object detail having the lowest perceptible contrast was recorded for each observer. Perceptibility curves were plotted according to the mean of observer data. The perceptibility curves for processed radiographs obtained with the F1 iOX system are higher than those for originals in the exposure range up to the peak, where the curves are basically the same. For radiographs exposed with the Dixi system, perceptibility curves for processed radiographs are higher than those for originals for all exposures. Perceptibility curves show that for 8 bit radiographs obtained from the F1 iOX system, the contrast threshold was increased in processed radiographs up to the peak, while for 12 bit radiographs obtained with the Dixi system, the contrast threshold was increased in processed radiographs for all exposures. When comparisons were made between radiographs corrected for attenuation and corrected for attenuation and visual response, basically no differences were found. Radiographs processed for correction for attenuation and correction for attenuation and visual response may improve perception, especially for 12 bit originals.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Latini, R. M.; Bellido, A. V. B.; Souza, M. I. S.

    In this study, the aim was to evaluate capabilities and constraints of radiographic imagery using thermal neutrons and gamma-rays as tools to identify the type of technique employed in ceramics manufacturing especially that used in prehistoric Brazilian pottery from Acre state. For this purpose, radiographic images of test objects made with clay of this region using both techniques - palette and rollers - have been acquired with a system comprised of a source of gamma-rays or thermal neutrons and a corresponding X-ray or neutron-sensitive Imaging Plate as detector. For the neutrongraphy samples were exposed to a thermal neutron flux ofmore » order of 10{sup 5}n.cm{sup −2}.s{sup −1} for 3 minutes at main port of Argonauta research reactor of the Instituto de Engenharia Nuclear - IEN/CNEN. The radiographic images using γ-rays from {sup 165}Dy (95 keV) and {sup 198}Au (412 keV) both produced at this reactor, have been acquired under an exposure time of a couple of hours. After acquisition, images have undergone a treatment to improve their quality through enhancement of their contrast, a procedure involving corrections of the beam divergence, sample shape and averaging of the attenuation map profile. Preliminary results show that difference between manufacturing techniques is better identified by radiography using low energy γ-rays from {sup 165}Dy rather than neutrongraphy or γ-rays from {sup 198}Au. Nevertheless, disregarding the kind of employed radiation, it should be stressed that feasibility to apply the technique is tightly tied to homogeneity of the clay itself and tempers due to their different attenuation.« less

  15. A New High Channel-Count, High Scan-Rate, Data Acquisition System for the NASA Langley Transonic Dynamics Tunnel

    NASA Technical Reports Server (NTRS)

    Ivanco, Thomas G.; Sekula, Martin K.; Piatak, David J.; Simmons, Scott A.; Babel, Walter C.; Collins, Jesse G.; Ramey, James M.; Heald, Dean M.

    2016-01-01

    A data acquisition system upgrade project, known as AB-DAS, is underway at the NASA Langley Transonic Dynamics Tunnel. AB-DAS will soon serve as the primary data system and will substantially increase the scan-rate capabilities and analog channel count while maintaining other unique aeroelastic and dynamic test capabilities required of the facility. AB-DAS is configurable, adaptable, and enables buffet and aeroacoustic tests by synchronously scanning all analog channels and recording the high scan-rate time history values for each data quantity. AB-DAS is currently available for use as a stand-alone data system with limited capabilities while development continues. This paper describes AB-DAS, the design methodology, and the current features and capabilities. It also outlines the future work and projected capabilities following completion of the data system upgrade project.

  16. Investigation of the hard x-ray background in backlit pinhole imagers.

    PubMed

    Fein, J R; Peebles, J L; Keiter, P A; Holloway, J P; Klein, S R; Kuranz, C C; Manuel, M J-E; Drake, R P

    2014-11-01

    Hard x-rays from laser-produced hot electrons (>10 keV) in backlit pinhole imagers can give rise to a background signal that decreases signal dynamic range in radiographs. Consequently, significant uncertainties are introduced to the measured optical depth of imaged plasmas. Past experiments have demonstrated that hard x-rays are produced when hot electrons interact with the high-Z pinhole substrate used to collimate the softer He-α x-ray source. Results are presented from recent experiments performed on the OMEGA-60 laser to further study the production of hard x-rays in the pinhole substrate and how these x-rays contribute to the background signal in radiographs. Radiographic image plates measured hard x-rays from pinhole imagers with Mo, Sn, and Ta pinhole substrates. The variation in background signal between pinhole substrates provides evidence that much of this background comes from x-rays produced in the pinhole substrate itself. A Monte Carlo electron transport code was used to model x-ray production from hot electrons interacting in the pinhole substrate, as well as to model measurements of x-rays from the irradiated side of the targets, recorded by a bremsstrahlung x-ray spectrometer. Inconsistencies in inferred hot electron distributions between the different pinhole substrate materials demonstrate that additional sources of hot electrons beyond those modeled may produce hard x-rays in the pinhole substrate.

  17. Fractographic Analysis of a Split Tooth Presenting Radiographically as a Horizontal Root Fracture in an Unrestored Mandibular Second Molar.

    PubMed

    Krishnan, Unni; Moule, Alex; Michael, Shaji; Swain, Michael

    2018-02-01

    Spontaneously catastrophic fracture of intact unrestored molar teeth is not common. Nevertheless, cracks do occur that progress apically, resulting in the complete splitting of the tooth and root. This report describes a catastrophic fracture that occurred in an unrestored mandibular second molar resulting in a previously unreported combination of a longitudinal and horizontal root fracture, appearing radiographically as a single horizontal root fracture. Tooth fragments were examined clinically, stereoscopically, and by scanning electron microscopy. Fractographic analysis was used to investigate the dynamics involved in fracture initiation, structural resistances encountered during progression of the fracture, and reasons for direction changes culminating in the unusual radiographic appearance. The uniqueness of this report is that it describes fractographic evidence of factors contributing to the initiation and progression of an in vivo crack. It shows fracture markings that are evidence of the energy dissipation mechanisms. The topographic location of these markings confirmed that cracks occur in vivo in stages with different rates of progression. This analysis helps to explain why split teeth are uncommon and highlights some of the multitude of factors that have to coincide for a tooth to catastrophically fracture. The report describes the mechanism of fracture and should stimulate clinicians and researchers to investigate cracking of teeth by undertaking fractographic analysis of extracted cracked teeth. Copyright © 2017 American Association of Endodontists. All rights reserved.

  18. Radiographic localization of unerupted mandibular anterior teeth.

    PubMed

    Jacobs, S G

    2000-10-01

    The parallax method and the use of 2 radiographs taken at right angles to each other are the 2 methods generally used to accurately localize teeth. For the parallax method, the combination of a rotational panoramic radiograph with an occlusal radiograph is recommended. This combination involves a vertical x-ray tube shift. Three case reports are presented that illustrate: (1) how this combination can accurately localize unerupted mandibular anterior teeth, (2) how a deceptive appearance of the labiolingual position of the unerupted tooth can be produced in an occlusal radiograph, (3) how increasing the vertical angle of the tube for the occlusal radiograph makes the tube shift easier to discern, (4) why occlusal radiographs are preferable to periapical radiographs for tube shifts, and (5) how localization can also be carried out with 2 radiographs at right angles to each other, one of which is an occlusal radiograph taken with the x-ray tube directed along the long axis of the reference tooth.

  19. 42 CFR 37.44 - Approval of radiographic facilities that use digital radiography systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... image acquisition, digitization, processing, compression, transmission, display, archiving, and... quality digital chest radiographs by submitting to NIOSH digital radiographic image files of a test object... digital radiographic image files from six or more sample chest radiographs that are of acceptable quality...

  20. 42 CFR 37.44 - Approval of radiographic facilities that use digital radiography systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... image acquisition, digitization, processing, compression, transmission, display, archiving, and... quality digital chest radiographs by submitting to NIOSH digital radiographic image files of a test object... digital radiographic image files from six or more sample chest radiographs that are of acceptable quality...

  1. A review of computer aided interpretation technology for the evaluation of radiographs of aluminum welds

    NASA Technical Reports Server (NTRS)

    Lloyd, J. F., Sr.

    1987-01-01

    Industrial radiography is a well established, reliable means of providing nondestructive structural integrity information. The majority of industrial radiographs are interpreted by trained human eyes using transmitted light and various visual aids. Hundreds of miles of radiographic information are evaluated, documented and archived annually. In many instances, there are serious considerations in terms of interpreter fatigue, subjectivity and limited archival space. Quite often it is difficult to quickly retrieve radiographic information for further analysis or investigation. Methods of improving the quality and efficiency of the radiographic process are being explored, developed and incorporated whenever feasible. High resolution cameras, digital image processing, and mass digital data storage offer interesting possibilities for improving the industrial radiographic process. A review is presented of computer aided radiographic interpretation technology in terms of how it could be used to enhance the radiographic interpretation process in evaluating radiographs of aluminum welds.

  2. CAPABILITIES AND SKILLS*

    PubMed Central

    Heckman, James J.; Corbin, Chase O.

    2016-01-01

    This paper discusses the relevance of recent research on the economics of human development to the work of the Human Development and Capability Association. The recent economics of human development brings insights about the dynamics of skill accumulation to an otherwise static literature on capabilities. Skills embodied in agents empower people. Enhanced skills enhance opportunities and hence promote capabilities. We address measurement problems common to both the economics of human development and the capability approach. The economics of human development analyzes the dynamics of preference formation, but is silent about which preferences should be used to evaluate alternative policies. This is both a strength and a limitation of the approach. PMID:28261378

  3. X-ray vision of fuel sprays.

    PubMed

    Wang, Jin

    2005-03-01

    With brilliant synchrotron X-ray sources, microsecond time-resolved synchrotron X-ray radiography and tomography have been used to elucidate the detailed three-dimensional structure and dynamics of high-pressure high-speed fuel sprays in the near-nozzle region. The measurement allows quantitative determination of the fuel distribution in the optically impenetrable region owing to the multiple scattering of visible light by small atomized fuel droplets surrounding the jet. X-radiographs of the jet-induced shock waves prove that the fuel jets become supersonic under appropriate injection conditions and that the quantitative analysis of the thermodynamic properties of the shock waves can also be derived from the most direct measurement. In other situations where extremely axial-asymmetric sprays are encountered, mass deconvolution and cross-sectional fuel distribution models can be computed based on the monochromatic and time-resolved X-radiographic images collected from various rotational orientations of the sprays. Such quantitative analysis reveals the never-before-reported characteristics and most detailed near-nozzle mass distribution of highly transient fuel sprays.

  4. The burden of non-radiographic axial spondyloarthritis.

    PubMed

    Boonen, Annelies; Sieper, Joachim; van der Heijde, Désirée; Dougados, Maxime; Bukowski, Jack F; Valluri, Satish; Vlahos, Bonnie; Kotak, Sameer

    2015-04-01

    To identify patients earlier, new classification criteria have been introduced for axial spondyloarthritis (axSpA). Patients who satisfy the clinical or imaging criteria for axSpA in the absence of definite sacroiliac joint changes on pelvic x-rays are classified as having non-radiographic axSpA. Although the burden associated with radiographic axSpA (i.e., ankylosing spondylitis) has been extensively studied, the impact of non-radiographic disease is not well understood. The purpose of this review is to provide an overview of the burden of illness in non-radiographic axSpA, including epidemiology and effects on patients׳ functioning and health-related quality of life (HR-QoL). A PubMed search was performed using relevant key words (e.g., "spondyloarthritis," "ankylosing spondylitis," "epidemiology," and "quality of life") to examine literature published from 2003 to 2013. Studies conducted to date suggest that radiographic progression is detected in approximately 10% of patients with non-radiographic axSpA over 2 years. Differences between patients with non-radiographic and radiographic axSpA were found in age, symptom duration, and gender distribution. Although less inflammation (i.e., lower C-reactive protein levels and less spinal inflammation on MRI) and less impairment in spinal mobility are observed in non-radiographic than in radiographic axSpA, the 2 conditions pose a similar burden in terms of disease activity, physical function, HR-QoL impairment. Patients with non-radiographic axSpA are more frequently female. Although patients with non-radiographic axSpA have shorter disease duration and lack radiological changes, they demonstrate a substantial burden of illness, with self-reported disease activity and functional impairments comparable to those found in patients with radiographic disease. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Analysis of polyethylene wear in plain radiographs

    PubMed Central

    2009-01-01

    Background and purpose Two-dimensional computerized radiographic techniques are frequently used to measure in vivo polyethylene (PE) wear after total hip arthroplasty (THA), and several variables in the clinical set-up may influence the amount of wear that is measured. We compared the repeatability and concurrent validity of linear PE wear on plain radiographs using the same software but a different number of radiographs. Methods We used either 1, 2, or 6 anteroposterior (AP) hip radiographs of 11 patients from a clinical THA series with 12 years of follow-up, and measured the PE wear with the software PolyWare 3D Pro. Repeatability within and concurrent validity between the different numbers of radiograph strategies were assessed using limits of agreement (LOAs) and bias. Results Observed median wear (range) in mm was 3.4 (1.6–4.6), 2.3 (0.7–4.9), and 4.0 (2.6–6.2) for the 1-, 2-, and 6-radiograph strategies. For repeatability, no bias (p > 0.41) was observed. LOAs around the bias were ± 0.6, ± 0.4, and ± 1.2 mm for the 1-, 2-, and 6-radiograph strategies. For concurrent validity, a bias (± LOA) between all pairwise comparisons was observed (p < 0.02) with 0.8 mm (± 2.5) between the 1- and 2-radiograph strategies, 1.0 mm (± 2.2) between the 1- and 6-radiograph strategies, and 1.8 mm (± 1.2) between the 2- and 6-radiograph strategies. Interpretation The number of radiographs used for wear measurement with a shadow-casting analysis method on plain AP radiographs influences the amount of linear wear measured. Results of PE wear obtained with PolyWare in studies using a different number of radiographs are not comparable. PMID:19995318

  6. Using superconducting undulator for enhanced imaging capabilities of MaRIE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yampolsky, Nikolai

    MaRIE x-ray free electron laser (FEL) is envisioned to deliver a burst of closely spaced in time pulses for enabling the capability of studying the dynamic processes in a sample. MaRIE capability can be largely enhanced using the superconducting undulator, which has the capability of doubling its period. This technology will allow reaching the photon energy as low as ~200-500 eV. As a result, the MaRIE facility will have a broader photon energy range enabling a larger variety of experiments. The soft x-ray capability is more likely to achieve the 3D imaging of dynamic processes in noncrystal materials than themore » hard x-ray capability alone.« less

  7. 42 CFR 37.44 - Approval of radiographic facilities that use digital radiography systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... effective management, safety, and proper performance of chest image acquisition, digitization, processing... digital chest radiographs by submitting to NIOSH digital radiographic image files of a test object (e.g... radiographic image files from six or more sample chest radiographs that are of acceptable quality to one or...

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silvani, M. I.; Almeida, G. L.; Lopes, R. T.

    Radiographic images acquired with point-like gamma-ray sources exhibit a desirable low penumbra effects specially when positioned far away from the set object-detector. Such an arrangement frequently is not affordable due to the limited flux provided by a distant source. A closer source, however, has two main drawbacks, namely the degradation of the spatial resolution - as actual sources are only approximately punctual - and the non-homogeneity of the beam hitting the detector, which creates a false attenuation map of the object being inspected. This non-homogeneity is caused by the beam divergence itself and by the different thicknesses traversed the beammore » even if the object were an homogeneous flat plate. In this work, radiographic images of objects with different geometries, such as flat plates and pipes have undergone a correction of beam divergence and attenuation addressing the experimental verification of the capability and soundness of an algorithm formerly developed to generate and process synthetic images. The impact of other parameters, including source-detector gap, attenuation coefficient, ratio defective-to-main hull thickness and counting statistics have been assessed for specifically tailored test-objects aiming at the evaluation of the ability of the proposed method to deal with different boundary conditions. All experiments have been carried out with an X-ray sensitive Imaging Plate and reactor-produced {sup 198}Au and {sup 165}Dy sources. The results have been compared with other technique showing a better capability to correct the attenuation map of inspected objects unveiling their inner structure otherwise concealed by the poor contrast caused by the beam divergence and attenuation, in particular for those regions far apart from the vertical of the source.« less

  9. Development of an Aeroelastic Modeling Capability for Transient Nozzle Side Load Analysis

    NASA Technical Reports Server (NTRS)

    Wang, Ten-See; Zhao, Xiang; Zhang, Sijun; Chen, Yen-Sen

    2013-01-01

    Lateral nozzle forces are known to cause severe structural damage to any new rocket engine in development during test. While three-dimensional, transient, turbulent, chemically reacting computational fluid dynamics methodology has been demonstrated to capture major side load physics with rigid nozzles, hot-fire tests often show nozzle structure deformation during major side load events, leading to structural damages if structural strengthening measures were not taken. The modeling picture is incomplete without the capability to address the two-way responses between the structure and fluid. The objective of this study is to develop a coupled aeroelastic modeling capability by implementing the necessary structural dynamics component into an anchored computational fluid dynamics methodology. The computational fluid dynamics component is based on an unstructured-grid, pressure-based computational fluid dynamics formulation, while the computational structural dynamics component is developed in the framework of modal analysis. Transient aeroelastic nozzle startup analyses of the Block I Space Shuttle Main Engine at sea level were performed. The computed results from the aeroelastic nozzle modeling are presented.

  10. Validation of a novel technique for creating simulated radiographs using computed tomography datasets.

    PubMed

    Mendoza, Patricia; d'Anjou, Marc-André; Carmel, Eric N; Fournier, Eric; Mai, Wilfried; Alexander, Kate; Winter, Matthew D; Zwingenberger, Allison L; Thrall, Donald E; Theoret, Christine

    2014-01-01

    Understanding radiographic anatomy and the effects of varying patient and radiographic tube positioning on image quality can be a challenge for students. The purposes of this study were to develop and validate a novel technique for creating simulated radiographs using computed tomography (CT) datasets. A DICOM viewer (ORS Visual) plug-in was developed with the ability to move and deform cuboidal volumetric CT datasets, and to produce images simulating the effects of tube-patient-detector distance and angulation. Computed tomographic datasets were acquired from two dogs, one cat, and one horse. Simulated radiographs of different body parts (n = 9) were produced using different angles to mimic conventional projections, before actual digital radiographs were obtained using the same projections. These studies (n = 18) were then submitted to 10 board-certified radiologists who were asked to score visualization of anatomical landmarks, depiction of patient positioning, realism of distortion/magnification, and image quality. No significant differences between simulated and actual radiographs were found for anatomic structure visualization and patient positioning in the majority of body parts. For the assessment of radiographic realism, no significant differences were found between simulated and digital radiographs for canine pelvis, equine tarsus, and feline abdomen body parts. Overall, image quality and contrast resolution of simulated radiographs were considered satisfactory. Findings from the current study indicated that radiographs simulated using this new technique are comparable to actual digital radiographs. Further studies are needed to apply this technique in developing interactive tools for teaching radiographic anatomy and the effects of varying patient and tube positioning. © 2013 American College of Veterinary Radiology.

  11. Dynamic locked plating for fixation of distal femur fractures using near- cortical over-drilling: Preliminary results of a prospective observational study.

    PubMed

    Galal, Sherif

    2017-01-01

    Nonunion after locked plating of distal femur fractures is not uncommon. Authors wanted to assess if "Dynamic" locked plating using near-cortex over-Drilling technique would provide a mechanical environment the promotes callus formation, thereby avoiding non-union encountered when applying locked plates with the conventional method. This study was conducted at an academic Level 1 Trauma Center. This is a prospective study conducted from November 2015 to November 2016. Follow-up was 10 months on average (ranging from 8 to 12 months). The study included 20 patients with 20 fractures (13 males, 7 females). The average patients' age was 41.2 years (18-64 years). According to the Müller AO classification of distal femur fractures (33A-C) there were 15 cases with extra-articular fractures (AO 33A), 5 patients with intra-articular fractures (AO 33C). Dynamic Locked plating using near-cortical over-drilling technique was done for all patients. Two blinded observers assessed callus score on 6-week radiographs using a 4-point ordinal scale. A 2-tailed t -test. Two-way mixed intra-class correlation testing was performed to determine reliability of the callus measurements by the 2 observers. All patients achieved union, time to union was 13.4 weeks on average (range form 8-24 weeks). Delayed union was observed in 2 patients. The average callus score for fractures was 1.8 (SD 0.6). All fractures united in alignment except 1 fracture which united in valgus malalignment, the deformity was appreciated in the postoperative radiographs. No wound related complications, no loss of reduction, no catastrophic implant failure or screw breakage were detected. Dynamic locked plating using near-cortex over-drilling is a simple technique that uses standard locked plates that promotes callus formation when used for fixing distal femur fractures.

  12. Intra-observer reproducibility and interobserver reliability of the radiographic parameters in the Spinal Deformity Study Group's AIS Radiographic Measurement Manual.

    PubMed

    Dang, Natasha Radhika; Moreau, Marc J; Hill, Douglas L; Mahood, James K; Raso, James

    2005-05-01

    Retrospective cross-sectional assessment of the reproducibility and reliability of radiographic parameters. To measure the intra-examiner and interexaminer reproducibility and reliability of salient radiographic features. The management and treatment of adolescent idiopathic scoliosis (AIS) depends on accurate and reproducible radiographic measurements of the deformity. Ten sets of radiographs were randomly selected from a sample of patients with AIS, with initial curves between 20 degrees and 45 degrees. Fourteen measures of the deformity were measured from posteroanterior and lateral radiographs by 2 examiners, and were repeated 5 times at intervals of 3-5 days. Intra-examiner and interexaminer differences were examined. The parameters include measures of curve size, spinal imbalance, sagittal kyphosis and alignment, maximum apical vertebral rotation, T1 tilt, spondylolysis/spondylolisthesis, and skeletal age. Intra-examiner reproducibility was generally excellent for parameters measured from the posteroanterior radiographs but only fair to good for parameters from the lateral radiographs, in which some landmarks were not clearly visible. Of the 13 parameters observed, 7 had excellent interobserver reliability. The measurements from the lateral radiograph were less reproducible and reliable and, thus, may not add value to the assessment of AIS. Taking additional measures encourages a systematic and comprehensive assessment of spinal radiographs.

  13. Advanced algorithms for radiographic material discrimination and inspection system design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilbert, Andrew J.; McDonald, Benjamin S.; Deinert, Mark R.

    X-ray and neutron radiography are powerful tools for non-invasively inspecting the interior of objects. Materials can be discriminated by noting how the radiographic signal changes with variations in the input spectrum or inspection mode. However, current methods are limited in their ability to differentiate when multiple materials are present, especially within large and complex objects. With X-ray radiography, the inability to distinguish materials of a similar atomic number is especially problematic. To overcome these critical limitations, we augmented our existing inverse problem framework with two important expansions: 1) adapting the previous methodology for use with multi-modal radiography and energy-integrating detectors,more » and 2) applying the Cramer-Rao lower bound to select an optimal set of inspection modes for a given application a priori. Adding these expanded capabilities to our algorithmic framework with adaptive regularization, we observed improved discrimination between high-Z materials, specifically plutonium and tungsten. The combined system can estimate plutonium mass within our simulated system to within 1%. Three types of inspection modes were modeled: multi-endpoint X-ray radiography alone; in combination with neutron radiography using deuterium-deuterium (DD); or in combination with neutron radiography using deuterium-tritium (DT) sources.« less

  14. What CORBA can do: An example of a new system developed with object technology: TeleMed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Forslund, D.; Phillips, R.; Tomlinson, B.

    1996-05-01

    The TeleMed application grew out of a relationship with physicians at the National Jewish Center for Immunology and Respiratory Medicine (NJC) in Denver. These physicians are experts in pulmonary diseases and radiology, helping patients combat effects of TB and other lung diseases. To make the knowledge and experience at NJC available to a wider audience, LANL has developed a virtual patient record system called TeleMed which is based on distributed national radiographic and patient record repository located throughout the country. Without leaving their offices, participating doctors can view clinical drug and radiographic data via a sophisticated multimedia interface. TeleMed ismore » also valuable for teaching and presentation as well. Thus a resident can use TeleMed for self-training in diagnostic techniques and a physician can use it to explain to a patient the course of their illness. Data can be viewed simultaneously by users at two or more distant locations for consultation with specialists in different fields. This capability is made possible by integration of multimedia information using commercial CORBA technology linking object-enable databases with client interfaces using a three-tiered architecture.« less

  15. Automated matching of corresponding seed images of three simulator radiographs to allow 3D triangulation of implanted seeds.

    PubMed

    Altschuler, M D; Kassaee, A

    1997-02-01

    To match corresponding seed images in different radiographs so that the 3D seed locations can be triangulated automatically and without ambiguity requires (at least) three radiographs taken from different perspectives, and an algorithm that finds the proper permutations of the seed-image indices. Matching corresponding images in only two radiographs introduces inherent ambiguities which can be resolved only with the use of non-positional information obtained with intensive human effort. Matching images in three or more radiographs is an 'NP (Non-determinant in Polynomial time)-complete' problem. Although the matching problem is fundamental, current methods for three-radiograph seed-image matching use 'local' (seed-by-seed) methods that may lead to incorrect matchings. We describe a permutation-sampling method which not only gives good 'global' (full permutation) matches for the NP-complete three-radiograph seed-matching problem, but also determines the reliability of the radiographic data themselves, namely, whether the patient moved in the interval between radiographic perspectives.

  16. Automated matching of corresponding seed images of three simulator radiographs to allow 3D triangulation of implanted seeds

    NASA Astrophysics Data System (ADS)

    Altschuler, Martin D.; Kassaee, Alireza

    1997-02-01

    To match corresponding seed images in different radiographs so that the 3D seed locations can be triangulated automatically and without ambiguity requires (at least) three radiographs taken from different perspectives, and an algorithm that finds the proper permutations of the seed-image indices. Matching corresponding images in only two radiographs introduces inherent ambiguities which can be resolved only with the use of non-positional information obtained with intensive human effort. Matching images in three or more radiographs is an `NP (Non-determinant in Polynomial time)-complete' problem. Although the matching problem is fundamental, current methods for three-radiograph seed-image matching use `local' (seed-by-seed) methods that may lead to incorrect matchings. We describe a permutation-sampling method which not only gives good `global' (full permutation) matches for the NP-complete three-radiograph seed-matching problem, but also determines the reliability of the radiographic data themselves, namely, whether the patient moved in the interval between radiographic perspectives.

  17. [Comparative Study of Patient Identifications for Conventional and Portable Chest Radiographs Utilizing ROC Analysis].

    PubMed

    Kawashima, Hiroki; Hayashi, Norio; Ohno, Naoki; Matsuura, Yukihiro; Sanada, Shigeru

    2015-08-01

    To evaluate the patient identification ability of radiographers, previous and current chest radiographs were assessed with observer study utilizing a receiver operating characteristics (ROCs) analysis. This study included portable and conventional chest radiographs from 43 same and 43 different patients. The dataset used in this study was divided into the three following groups: (1) a pair of portable radiographs, (2) a pair of conventional radiographs, and (3) a combination of each type of radiograph. Seven observers participated in this ROC study, which aimed to identify same or different patients, using these datasets. ROC analysis was conducted to calculate the average area under ROC curve obtained by each observer (AUCave), and a statistical test was performed using the multi-reader multi-case method. Comparable results were obtained with pairs of portable (AUCave: 0.949) and conventional radiographs (AUCave: 0.951). In a comparison between the same modality, there were no significant differences. In contrast, the ability to identify patients by comparing a portable and conventional radiograph (AUCave: 0.873) was lower than with the matching datasets (p=0.002 and p=0.004, respectively). In conclusion, the use of different imaging modalities reduces radiographers' ability to identify their patients.

  18. Radiology of adolescent slipped capital femoral epiphysis: measurement of epiphyseal angles and diagnosis.

    PubMed

    Gekeler, Jörg

    2007-10-01

    AIMS OF DIAGNOSTIC RADIOGRAPHY: Visualization of the proximal femur in two clearly defined projections. Radiologic and morphological diagnosis of slipped capital femoral epiphysis. Evaluation of the stability of the femoral epiphysis: chronic slippage or acute interruption of continuity between the femoral epiphysis and the femoral neck metaphysis. Radiometric measurement of the spatial deformity of the femoral epiphysis. Measurement of the projected epiphyseal angle on the radiograph as the basis for possible conversion into anatomically correct angles at the proximal femur. Preoperative planning of therapeutic surgical procedures. Idiopathic hip pain in the growing child or adolescent. Referred pain to the knee or thigh. Unusual gait pattern with external rotation deformity of the leg, limping that favors one leg or limping due to leg length discrepancy. Abnormal sonography, CT or MRI findings. Eventful history including minor injury or genuine trauma. Symptoms and uncommon physical constitution: obesity, exceptional longitudinal growth of the extremities, and absence of secondary sex characteristics. Indications for Radiographic Imaging of the Hip Joint in Two Planes None. Standard positioning of the patient or the affected extremity. First standard radiograph: proximal femur in anteroposterior projection. Position of the leg with the patella directed anteriorly. Contraction of the external rotators at the hip joint is compensated by elevation of the hip until the leg is in the neutral position. Second standard radiograph: axial view of the proximal femur in anteroposterior projection. Leg flexed to 90 degrees at the hip and in 45 degrees abduction. Thigh position parallel to the longitudinal axis of the table (zero rotation). Early signs of incipient or imminent femoral epiphyseolysis: --Disintegration, widening and blurred margins of the epiphyseal plate. --Increasing loss of height of the femoral epiphysis due to incipient dislocation. --The tangent to the lateral femoral neck intersects only slightly with the femoral head or runs tangential to the epiphysis. --Important second radiograph in axial projection: incipient slippage is seen early here. Comparison with the contralateral side. Chronic slipped capital femoral epiphysis in adolescents: --Advanced epiphyseal dislocation visible in both planes. The tangent to the lateral femoral neck no longer intersects with the dislocated femoral epiphysis. In some cases, varus deformity of the femoral neck and periosteal elevation at the borders of the medial femoral neck. --Epiphyseal dislocation even more apparent in the axial view. Acute slipped capital femoral epiphysis in adolescents: --Complete interruption of continuity between epiphysis and metaphysis. --Widened gap between epiphysis and metaphysis. --Cystic irregularities of the metaphysis. --In most cases, substantial dislocation between epiphysis and metaphysis. --"Acute on chronic slip": specific type of acute epiphyseal dislocation subsequent to chronic epiphyseolysis. In addition to signs of acute separation, secondary symptoms of chronic epiphyseolysis such as femoral neck arcuation and spur formation at the head-neck junction. --Dynamic fluoroscopy may be indicated to confirm acute dislocation. Defined axes are marked on the radiograph: anatomic axis of the femur, femoral neck axis, and so-called epiphyseal axis (perpendicular to the base of the epiphysis). Measurement of the projected epiphysis-diaphysis angle (ED' angle) on the anteroposterior radiograph and the projected epiphyseal torsion angle (ET' angle) on the axial radiograph. For slight to moderate slippage, the difference between the epiphyseal dislocation angle obtained from the radiographs (as projected in two planes) compared with the anatomic, i.e., real dislocation angle at the proximal femur is generally relatively minor. Conversion of the projected angle to the real angle is not essential in these cases (if in doubt, see Table 1). For more severe dislocations, the differences between the projected and real angles are far more apparent. Table 1 facilitates conversion of the epiphyseal dislocation angles taken from the radiograph into anatomically correct dislocation angles at the proximal femur. Conversion to real angles, especially for preoperative planning of complex corrective surgery, is indicated for more severe deformities of the femoral epiphysis. Conversion into real (anatomic) angles is indicated for exact prognostic evaluation of prearthrotic deformities.

  19. Scinticisternography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paris, A. Jr.; Caleel, G.T.

    1975-03-01

    Scinticisternography is a physiologic method of evaluating the cerebrospinal fluid spaces and dynamics, and complements radiographic techniques. Improvements in radiopharmaceutical agents and in imaging devices have made the procedure almost a routine part of examination of patients with neurologic disease. It is particularly valuable for patients with hydrocephalus, for whom accurate identification of the cause of dementia opens the possibility of correction by a shunting procedure. The danger of radiation damage with currently accepted dosage is slight, and the risk of meningitis can be minimized if proper precautions are observed.

  20. Improving the Quality of Radiographs in Neonatal Intensive Care Unit Utilizing Educational Interventions.

    PubMed

    Gupta, Ashish O; Rorke, Jeanne; Abubakar, Kabir

    2015-08-01

    We aimed to develop an educational tool to improve the radiograph quality, sustain this improvement overtime, and reduce the number of repeat radiographs. A three phase quality control study was conducted at a tertiary care NICU. A retrospective data collection (phase1) revealed suboptimal radiograph quality and led to an educational intervention and development of X-ray preparation checklist (primary intervention), followed by a prospective data collection for 4 months (phase 2). At the end of phase 2, interim analysis revealed a gradual decline in radiograph quality, which prompted a more comprehensive educational session with constructive feedback to the NICU staff (secondary intervention), followed by another data collection for 6 months (phase 3). There was a significant improvement in the quality of radiographs obtained after primary educational intervention (phase 2) compared with phase 1 (p < 0.001). During interim analysis after phase 2, radiograph quality declined but still remained significantly better than phase 1. Secondary intervention resulted in significant improvement in radiograph quality to > 95% in all domains of image quality. No radiographs were repeated in phase 3, compared with 5.8% (16/277) in phase 1. A structured, collaborated educational intervention successfully improves the radiograph quality and decreases the need for repeat radiographs and radiation exposure in the neonates. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Digital image analysis: improving accuracy and reproducibility of radiographic measurement.

    PubMed

    Bould, M; Barnard, S; Learmonth, I D; Cunningham, J L; Hardy, J R

    1999-07-01

    To assess the accuracy and reproducibility of a digital image analyser and the human eye, in measuring radiographic dimensions. We experimentally compared radiographic measurement using either an image analyser system or the human eye with digital caliper. The assessment of total hip arthroplasty wear from radiographs relies on both the accuracy of radiographic images and the accuracy of radiographic measurement. Radiographs were taken of a slip gauge (30+/-0.00036 mm) and slip gauge with a femoral stem. The projected dimensions of the radiographic images were calculated by trigonometry. The radiographic dimensions were then measured by blinded observers using both techniques. For a single radiograph, the human eye was accurate to 0.26 mm and reproducible to +/-0.1 mm. In comparison the digital image analyser system was accurate to 0.01 mm with a reproducibility of +/-0.08 mm. In an arthroplasty model, where the dimensions of an object were corrected for magnification by the known dimensions of a femoral head, the human eye was accurate to 0.19 mm, whereas the image analyser system was accurate to 0.04 mm. The digital image analysis system is up to 20 times more accurate than the human eye, and in an arthroplasty model the accuracy of measurement increases four-fold. We believe such image analysis may allow more accurate and reproducible measurement of wear from standard follow-up radiographs.

  2. Determining paediatric patient thickness from a single digital radiograph-a proof of principle.

    PubMed

    Worrall, Mark; Vinnicombe, Sarah; Sutton, David G

    2018-04-05

    This work presents a proof of principle for a method of estimating the thickness of an attenuator from a single radiograph using the image, the exposure factors with which it was acquired and a priori knowledge of the characteristics of the X-ray unit and detector used for the exposure. It is intended this could be developed into a clinical tool to assist with paediatric patient dose audit, for which a measurement of patient size is required. The proof of principle used measured pixel value and effective linear attenuation coefficient to estimate the thickness of a Solid Water attenuator. The kerma at the detector was estimated using a measurement of pixel value on the image and measured detector calibrations. The initial kerma was estimated using a lookup table of measured output values. The effective linear attenuation coefficient was measured for Solid Water at varying kV p . 11 test images of known and varying thicknesses of Solid Water were acquired at 60, 70 and 81 kV p . Estimates of attenuator thickness were made using the model and the results compared to the known thickness. Estimates of attenuator thickness made using the model differed from the known thickness by 3.8 mm (3.2%) on average, with a range of 0.5-10.8 mm (0.5-9%). A proof of principle is presented for a method of estimating the thickness of an attenuator using a single radiograph of the attenuator. The method has been shown to be accurate using a Solid Water attenuator, with a maximum difference between estimated and known attenuator thickness of 10.8 mm (9%). The method shows promise as a clinical tool for estimating abdominal paediatric patient thickness for paediatric patient dose audit, and is only contingent on the type of data routinely collected by Medical Physics departments. Advances in knowledge: A computational model has been created that is capable of accurately estimating the thickness of a uniform attenuator using only the radiographic image, the exposure factors with which it was acquired and a priori knowledge of the characteristics of the X-ray unit and detector used for the exposure.

  3. The value of routine chest radiographs in acute asthma admissions.

    PubMed

    Ismail, Y; Loo, C S; Zahary, M K

    1994-04-01

    We reviewed 116 chest radiographs done in 70 adult asthmatic patients who were admitted to the Hospital Universiti Sains Malaysia from January to December 1989. The chest radiographs were abnormal in 23% of cases. Twelve percent showed hyperinflation and 7% had pneumonia. Eight patients diagnosed clinically to have pneumonia had normal chest radiographs. Seven patients had radiographic findings of conditions which were unsuspected clinically. These included two cases of pneumonia, one case each of fibrosing alveolitis, pneumothorax, pneumomediastinum, mitral stenosis with left ventricular failure and right pleural effusion. In conclusion, we found that significant chest radiograph abnormalities in adult patients admitted for asthma were uncommon although chest radiographs were helpful in detecting complications or coincidental conditions. Chest radiograph is therefore an important investigation in adult asthmatic patients who are admitted. However, considering the cost and the risk of radiation, it should be done only in selective cases rather than as a routine procedure.

  4. A survey of radiographers' confidence and self-perceived accuracy in frontline image interpretation and their continuing educational preferences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neep, Michael J; Centre for Functioning and Health Research, Metro South Health, Brisbane, Queensland; School of Public Health and Social Work and Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Queensland

    The provision of a written comment on traumatic abnormalities of the musculoskeletal system detected by radiographers can assist referrers and may improve patient management, but the practice has not been widely adopted outside the United Kingdom. The purpose of this study was to investigate Australian radiographers' perceptions of their readiness for practice in a radiographer commenting system and their educational preferences in relation to two different delivery formats of image interpretation education, intensive and non-intensive. A cross-sectional web-based questionnaire was implemented between August and September 2012. Participants included radiographers with experience working in emergency settings at four Australian metropolitan hospitals.more » Conventional descriptive statistics, frequency histograms, and thematic analysis were undertaken. A Wilcoxon signed-rank test examined whether a difference in preference ratings between intensive and non-intensive education delivery was evident. The questionnaire was completed by 73 radiographers (68% response rate). Radiographers reported higher confidence and self-perceived accuracy to detect traumatic abnormalities than to describe traumatic abnormalities of the musculoskeletal system. Radiographers frequently reported high desirability ratings for both the intensive and the non-intensive education delivery, no difference in desirability ratings for these two formats was evident (z = 1.66, P = 0.11). Some Australian radiographers perceive they are not ready to practise in a frontline radiographer commenting system. Overall, radiographers indicated mixed preferences for image interpretation education delivered via intensive and non-intensive formats. Further research, preferably randomised trials, investigating the effectiveness of intensive and non-intensive education formats of image interpretation education for radiographers is warranted.« less

  5. The x-ray light valve: a low-cost, digital radiographic imaging system-spatial resolution

    NASA Astrophysics Data System (ADS)

    MacDougall, Robert D.; Koprinarov, Ivaylo; Webster, Christie A.; Rowlands, J. A.

    2007-03-01

    In recent years, new x-ray radiographic systems based on large area flat panel technology have revolutionized our capability to produce digital x-ray radiographic images. However, these active matrix flat panel imagers (AMFPIs) are extraordinarily expensive compared to the systems they are replacing. Thus there is a need for a low cost digital imaging system for general applications in radiology. Different approaches have been considered to make lower cost, integrated x-ray imaging devices for digital radiography, including: scanned projection x-ray, an integrated approach based on computed radiography technology and optically demagnified x-ray screen/CCD systems. These approaches suffer from either high cost or high mechanical complexity and do not have the image quality of AMFPIs. We have identified a new approach - the X-ray Light Valve (XLV). The XLV has the potential to achieve the immediate readout in an integrated system with image quality comparable to AMFPIs. The XLV concept combines three well-established and hence lowcost technologies: an amorphous selenium (a-Se) layer to convert x-rays to image charge, a liquid crystal (LC) cell as an analog display, and an optical scanner for image digitization. Here we investigate the spatial resolution possible with XLV systems. Both a-Se and LC cells have both been shown separately to have inherently very high spatial resolution. Due to the close electrostatic coupling in the XLV, it can be expected that the spatial resolution of this system will also be very high. A prototype XLV was made and a typical office scanner was used for image digitization. The Modulation Transfer Function was measured and the limiting factor was seen to be the optical scanner. However, even with this limitation the XLV system is able to meet or exceed the resolution requirements for chest radiography.

  6. Age prediction formulae from radiographic assessment of skeletal maturation at the knee in an Irish population.

    PubMed

    O'Connor, Jean E; Coyle, Joseph; Bogue, Conor; Spence, Liam D; Last, Jason

    2014-01-01

    Age estimation in living subjects is primarily achieved through assessment of a hand-wrist radiograph and comparison with a standard reference atlas. Recently, maturation of other regions of the skeleton has also been assessed in an attempt to refine the age estimates. The current study presents a method to predict bone age directly from the knee in a modern Irish sample. Ten maturity indicators (A-J) at the knee were examined from radiographs of 221 subjects (137 males; 84 females). Each indicator was assigned a maturity score. Scores for indicators A-G, H-J and A-J, respectively, were totalled to provide a cumulative maturity score for change in morphology of the epiphyses (AG), epiphyseal union (HJ) and the combination of both (AJ). Linear regression equations to predict age from the maturity scores (AG, HJ, AJ) were constructed for males and females. For males, equation-AJ demonstrated the greatest predictive capability (R(2)=0.775) while for females equation-HJ had the strongest capacity for prediction (R(2)=0.815). When equation-AJ for males and equation-HJ for females were applied to the current sample, the predicted age of 90% of subjects was within ±1.5 years of actual age for male subjects and within +2.0 to -1.9 years of actual age for female subjects. The regression formulae and associated charts represent the most contemporary method of age prediction currently available for an Irish population, and provide a further technique which can contribute to a multifactorial approach to age estimation in non-adults. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. Ultrasound Imaging of Spine: State of the Art and Utility for Space Flight

    NASA Technical Reports Server (NTRS)

    Sargsyan, Ashot E.; Bouffard, Antonio J.; Garcia, Kathleen; Hamilton, Douglas R.; Van Holsbeeck, Marnix; Ebert, Douglas J. W.; Dulchavsky, Scott A.

    2010-01-01

    Introduction: Ultrasound imaging (sonography) has been increasingly used for both primary diagnosis and monitoring of musculoskeletal injury, including fractures. In certain injuries, sonography has been shown to equal or surpass Magnetic Resonance Imaging in accuracy. Long-term exposure to reduced gravity may be expected to cause physiological and anatomical changes of the musculoskeletal system, which are not fully described or understood. In a limited-resource environment like space flight, sonography will likely remain the only imaging modality; therefore, further attention to its potential is warranted, including its ability to image anatomical deviations as well as irregularities of vertebrae and the spinal column. Methods: A thorough review of literature was conducted on the subject. A multipurpose ultrasound system was used to identify specific vertebrae, intervertebral disks, and other structures of the cervical spine in healthy volunteers, selected to represent various age, gender, and Body Mass Index (BMI) groups. Sonographic views were sought that would parallel radiographic views and signs used in the diagnosis of cervical spine injuries. Results: While using widely accepted radiographic signs of cervical spine injury, this sonographic protocol development effort resulted in successful identification of scanning planes and imaging protocols that could serve as alternatives for radiography. Some of these views are also applicable to diagnosing degenerative disk and bone disease, and other non-traumatic spine pathology. Strong, preliminary correlation has been demonstrated in a number of clinical cases between sonography and other imaging modalities. Conclusion: In the absence of radiography, sonography can be used to diagnose or rule out certain common types of cervical spine conditions including injury. Clinical validation of the findings appears to be realistic and would facilitate establishment of new sonographic protocols for special environments with lacking radiographic capability, such as human space flight.

  8. Experimental investigation of dynamic fragmentation of laser shock-loaded by soft recovery and X-ray radiography

    NASA Astrophysics Data System (ADS)

    Xin, Jianting; He, Weihua; Chu, Genbai; Gu, Yuqiu

    2017-06-01

    Dynamic fragmentation of metal under shock pressure is an important issue for both fundamental science and practical applications. And in recent decades, laser provides a promising shock loading technique for investigating the process of dynamic fragmentation under extreme condition application of high strain rate. Our group has performed experimental investigation of dynamic fragmentation under laser shock loading by soft recovery and X-ray radiography at SGC / ó prototype laser facility. The fragments under different loading pressures were recovered by PMP foam and analyzed by X-ray micro-tomography and the improved watershed method. The experiment result showed that the bilinear exponential distribution is more appropriate for representing the fragment size distribution. We also developed X-ray radiography technique. Owing to its inherent advantage over shadowgraph technique, X-ray radiography can potentially determine quantitatively material densities by measuring the X-ray transmission. Our group investigated dynamic process of microjetting by X-ray radiography technique, the recorded radiographic images show clear microjetting from the triangular grooves in the free surface of tin sample.

  9. Evaluation of a High-Resolution Benchtop Micro-CT Scanner for Application in Porous Media Research

    NASA Astrophysics Data System (ADS)

    Tuller, M.; Vaz, C. M.; Lasso, P. O.; Kulkarni, R.; Ferre, T. A.

    2010-12-01

    Recent advances in Micro Computed Tomography (MCT) provided the motivation to thoroughly evaluate and optimize scanning, image reconstruction/segmentation and pore-space analysis capabilities of a new generation benchtop MCT scanner and associated software package. To demonstrate applicability to soil research the project was focused on determination of porosities and pore size distributions of two Brazilian Oxisols from segmented MCT-data. Effects of metal filters and various acquisition parameters (e.g. total rotation, rotation step, and radiograph frame averaging) on image quality and acquisition time are evaluated. Impacts of sample size and scanning resolution on CT-derived porosities and pore-size distributions are illustrated.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, Harold C.; Ibanez, Daniel Alejandro

    This report documents the ASC/ATDM Kokkos deliverable "Production Portable Dy- namic Task DAG Capability." This capability enables applications to create and execute a dynamic task DAG ; a collection of heterogeneous computational tasks with a directed acyclic graph (DAG) of "execute after" dependencies where tasks and their dependencies are dynamically created and destroyed as tasks execute. The Kokkos task scheduler executes the dynamic task DAG on the target execution resource; e.g. a multicore CPU, a manycore CPU such as Intel's Knights Landing (KNL), or an NVIDIA GPU. Several major technical challenges had to be addressed during development of Kokkos' Taskmore » DAG capability: (1) portability to a GPU with it's simplified hardware and micro- runtime, (2) thread-scalable memory allocation and deallocation from a bounded pool of memory, (3) thread-scalable scheduler for dynamic task DAG, (4) usability by applications.« less

  11. 10 CFR 34.33 - Permanent radiographic installations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Permanent radiographic installations. 34.33 Section 34.33 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.33 Permanent radiographic installations. (a...

  12. 10 CFR 34.33 - Permanent radiographic installations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Permanent radiographic installations. 34.33 Section 34.33 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.33 Permanent radiographic installations. (a...

  13. 10 CFR 34.33 - Permanent radiographic installations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Permanent radiographic installations. 34.33 Section 34.33 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.33 Permanent radiographic installations. (a...

  14. 10 CFR 34.33 - Permanent radiographic installations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Permanent radiographic installations. 34.33 Section 34.33 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.33 Permanent radiographic installations. (a...

  15. 10 CFR 34.33 - Permanent radiographic installations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Permanent radiographic installations. 34.33 Section 34.33 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.33 Permanent radiographic installations. (a...

  16. Quantitative analysis of scapholunate diastasis using stress speckle-tracking sonography: a proof-of-concept and feasibility study.

    PubMed

    Gondim Teixeira, Pedro Augusto; Badr, Sammy; Hossu, Gabriela; Lefebvre, Guillaume; Abou Arab, Waled; Blum, Alain; Cotten, Anne

    2017-12-01

    To evaluate the feasibility and potential clinical applicability of speckle-tracking sonography for the dynamic evaluation of the scapholunate diastasis during stress manoeuvres. Two readers used speckle tracking sonography to evaluate scapholunate diastasis during a clenching fist manoeuver in 30 normal wrists. Scapholunate peak strain, mean scapholunate diastasis and the diastasis variation coefficient were analysed. IRB exemption was granted for this study. Conventional and stress wrist radiographs of 26 patients with and without a scapholunate ligament tear were retrospectively analysed to ascertain the range of variation in scapholunate diastasis. Speckle-tracking parameters in normal wrists were similar between the two readers (p  > 0.2061). The maximal scapholunate peak strain during stress was relatively low (<0.34-0.47 mm). The normal radiographic diastasis amplitude was similar to maximal strain peak values in normal volunteers (0.49 ± 0.51 mm). The radiographic diastasis amplitude in cases of scapholunate ligament tears was 1.48 ± 0.78 mm, which was higher than the 95% confidence interval of the scapholunate gap peak strain. Speckle-tracking sonography could represent an interesting alternative for stress evaluation of the scapholunate ligament in patients with scapholunate diastasis. • Speckle-tracking sonography can assess scapholunate diastasis under stress testing. • Scapholunate gap shows little variation under stress in healthy volunteers. • Scapholunate gap measurements are influenced by grip strength. • Sex and BMI have a significant influence on strain measurements.

  17. A modified laryngeal tie-forward procedure using metallic implants for treatment of dorsal displacement of the soft palate in horses.

    PubMed

    Rossignol, Fabrice; Ouachée, Emilie; Boening, Karl Josef

    2012-08-01

    To describe a modified laryngeal tie-forward procedure (LTFP) using metallic implants. Retrospective case series. Twenty-seven horses (including 24 race horses) with dorsal displacement of the soft palate (DDSP) or palatal instability (PI) diagnosed using high-speed treadmill endoscopy (n = 15), history and resting examination (n = 8), or dynamic endoscopy over ground (n = 4). All horses underwent the modified LTFP. Modifications of the surgical procedure consisted in the use of 3 metallic stents called Suture Button(TM) through which the sutures are threaded and in a tying technique that involved a single knot connecting left and right suture loops (versus tying each separately). Lateral radiographs were taken 24 hours after surgery. Follow-up was obtained by telephone communication with trainers or owners. Surgery was performed without complications on all horses. The 3 metallic buttons were clearly visible on the postoperative radiographic examination. No evidence of suture breakage was observed 24 hours postoperatively based on radiographs. In other aspects, this technique is not very different from that originally described by Ducharme et al; it is an innovation that could offer some advantages to the surgeons and increase suture resistance to pullout from the thyroid cartilage. Our technique was used without complication in a small group of horses and return to performance may be similar to the original technique. © Copyright 2012 by The American College of Veterinary Surgeons.

  18. SPAR improved structure/fluid dynamic analysis capability

    NASA Technical Reports Server (NTRS)

    Oden, J. T.; Pearson, M. L.

    1983-01-01

    The capability of analyzing a coupled dynamic system of flowing fluid and elastic structure was added to the SPAR computer code. A method, developed and adopted for use in SPAR utilizes the existing assumed stress hybrid plan element in SPAR. An operational mode was incorporated in SPAR which provides the capability for analyzing the flaw of a two dimensional, incompressible, viscous fluid within rigid boundaries. Equations were developed to provide for the eventual analysis of the interaction of such fluids with an elastic solid.

  19. Radiological Determination of Postoperative Cervical Fusion: A Systematic Review.

    PubMed

    Rhee, John M; Chapman, Jens R; Norvell, Daniel C; Smith, Justin; Sherry, Ned A; Riew, K Daniel

    2015-07-01

    Systematic review. To determine best criteria for radiological determination of postoperative subaxial cervical fusion to be applied to current clinical practice and ongoing future research assessing fusion to standardize assessment and improve comparability. Despite availability of multiple imaging modalities and criteria, there remains no method of determining cervical fusion with absolute certainty, nor clear consensus on specific criteria to be applied. A systematic search in MEDLINE/Cochrane Collaboration Library (through March 2014). Included studies assessed C2 to C7 via anterior or posterior approach, at 12 weeks or more postoperative, with any graft or implant. Overall body of evidence with respect to 6 posited key questions was determined using Grading of Recommendations Assessment, Development and Evaluation and Agency for Healthcare Research and Quality precepts. Of plain radiographical modalities, there is moderate evidence that the interspinous process motion method (<1 mm) is more accurate than the Cobb angle method for assessing anterior cervical fusion. Of the advanced imaging modalities, there is moderate evidence that computed tomography (CT) is more accurate and reliable than magnetic resonance imaging in assessing anterior cervical fusion. There is insufficient evidence regarding the optimal modality and criteria for assessing posterior cervical fusions and insufficient evidence to support a single time point after surgery as being optimal for determining fusion, although some evidence suggest that reliability of radiography and CT improves with increasing time postoperatively. We recommend using less than 1-mm motion as the initial modality for determining anterior cervical arthrodesis for both clinical and research applications. If further imaging is needed because of indeterminate radiographical evaluation, we recommend CT, which has relatively high accuracy and reliability, but due to greater radiation exposure and cost, it is not routinely suggested. We recommend that plain radiographs also be the initial method of determining posterior cervical fusion but suggest a lower threshold for obtaining CT scans because dynamic radiographs may not be as useful if spinous processes have been removed by laminectomy. 1.

  20. Radiographic localization of unerupted maxillary anterior teeth using the vertical tube shift technique: the history and application of the method with some case reports.

    PubMed

    Jacobs, S G

    1999-10-01

    The preferred means of radiographic localization is the parallax method introduced by Clark in 1910. He used 2 periapical radiographs and shifted the tube in the horizontal plane. In 1952, Richards appreciated that a vertical tube shift could also be carried out. No major changes then occurred in the technique until Keur, in Australia, in 1986 replaced the periapical radiographs with occlusal radiographs. This modification enables a greater tube movement and therefore a greater shift of the image of the impacted tooth; it also ensures that the whole of the tooth is captured on the radiograph. For the vertical tube shift, Keur introduced the use of a rotational panoramic radiograph with an occlusal radiograph. In 1987, Southall and Gravely discussed this vertical tube shift combination in the English dental literature, and it is now the preferred combination of radiographs for localizing impacted maxillary anterior teeth. Jacobs introduced this method to the American literature in 1999, but it has yet to gain acceptance in the continental European literature. Jacobs recommended, when using this combination, to routinely increase the vertical angulation for the occlusal radiograph by 10 degrees to achieve a greater image shift. Four case reports are presented in this article. Three have photographs taken at surgical exposure to illustrate how the position of the impacted tooth can be accurately predicted by appropriate interpretation of the radiographs.

  1. Radiographers' perceptions of their professional rights in diagnostic radiography: a qualitative interview study.

    PubMed

    Matilainen, Kati; Ahonen, Sanna-Mari; Kankkunen, Päivi; Kangasniemi, Mari

    2017-03-01

    Considering the ethics of each profession is important as inter-professional collaboration increases. Professional ethics creates a basis for radiographers' work, as it includes values and principles, together with rights and duties that guide and support professionals. However, little is known about radiographers' rights when it comes to professional ethics. The aim of this study was to describe radiographers' perceptions and experiences of their professional rights. The ultimate aim was to increase the understanding of professional ethics in this context and support radiographers' ethical pondering in diagnostic radiography. A qualitative method was used. Semistructured group interviews with 15 radiographers were conducted in spring 2013 at two publicly provided diagnostic imaging departments in Finland. Data were analysed by inductive content analysis. All the participants were women, and they had worked as radiographers for an average of 18 years. Based on our analysis, radiographers' professional rights consisted of rights related to their expertise in radiography and the rights related to working conditions that ensured their wellbeing. Expertise-based rights included rights to plan, conduct and assess radiological care with patient advocacy. Radiographers have the right to contribute to a culture of safe radiation in their organisation and to use their professional knowledge to achieve their main target, which is the safe imaging of patients. Radiographers also have right to work in conditions that support their well-being, including the legal rights stated in their employment contract, as well as their rights concerning resources at work. Radiographers' professional rights are an elementary and multidimensional part of their clinical practice. In future, more theoretical and empirical research is needed to deepen the understanding of their rights in the clinical practice and support radiographers on issues related to this aspect of their work. © 2016 Nordic College of Caring Science.

  2. Radiographers' performance in chest X-ray interpretation: the Nigerian experience

    PubMed Central

    Egbe, N O; Akpan, B E

    2015-01-01

    Objective: To assess the performance of Nigerian radiographers in interpretation of plain chest radiographs and to assess whether age, years since qualification and sector of practice are associated with performance. Methods: A test set of 50 radiographs containing 23 cases with no pathology (normal) and 27 abnormal cases (cardiopulmonary conditions) independently confirmed by 3 radiologists were presented to 51 radiographers in a random order. Readers independently evaluated radiographs for absence or presence of disease and stated the location, radiographic features and diagnosis. Readers self-reported their age, years since qualification and sector of practice. Receiver operating characteristic was used to assess the performance. Mann–Whitney U test was used to assess whether age, years since qualification and sector of practice were associated with performance. Results: Mean location sensitivity was 88.9 [95% confidence interval (CI), 0.787–0.980]. Mean sensitivity and specificity were 76.9 (95% CI, 0.658–0.864) and 79.8 (95% CI, 0.658–0.864), respectively. Age was not associated with performance (p = 0.07). Number of years qualified as radiographer (p = 0.005) and private practice (p = 0.004) were positively associated with performance. Conclusion: Nigerian radiographers can correctly report chest radiographs to a reasonable standard, and performance is associated with number of years since qualification and the sector of practice. Advances in knowledge: There are less than 300 radiologists serving a Nigerian population of about 170 million; therefore, X-ray interpretation by radiographers deserves consideration. Nigerian radiographers have potential to interpret chest X-ray in the clinical setting, and this may significantly improve radiology service delivery in this region. PMID:25966290

  3. Evaluation of thoracic radiographs as a screening test for dogs and cats admitted to a tertiary-care veterinary hospital for noncardiopulmonary disease.

    PubMed

    Keyserling, Christine L; Buriko, Yekaterina; Lyons, Bridget M; Drobatz, Kenneth J; Fischetti, Anthony J

    2017-09-01

    Thoracic radiographs are used as a screening tool for dogs and cats with a variety of disorders that have no clinical signs associated with thoracic structures. However, this practice has never been supported by an evidence-based study. The objective of this retrospective observational study was to determine if certain canine and feline populations have a higher proportion of radiographic abnormalities, and whether any of these abnormalities are associated with patient hospitalization and outcome. Patients were excluded if current or previous examinations revealed evidence of primary respiratory or cardiac disease, malignant neoplasia, or an abnormal breathing pattern consistent with pulmonary pathology. Any notable thoracic change in the radiology report was considered important and evaluated in this study. One hundred and sixty-six of these included patients were dogs and 65 were cats. Of the 166 dog radiographs evaluated, 120 (72.3%) had normal thoracic radiographs, while 46 (27.7%) had radiographic abnormalities. Of the sixty-five cats included, 36 (55.4%) had normal radiographs, while 29 (44.6%) had abnormal radiographs. Canine patients with abnormal radiographs had a significantly higher lactate level (P-value 0.0348) and feline patients with abnormal radiographs had a significantly lower packed cell volume (P-value 0.012). A large proportion of patients that had screening thoracic radiographs (32.5%) had documented abnormalities, but a relatively low percentage (6.5%) of our total population had their clinical plan changed as a consequence of detection of these abnormalities. Findings indicated that abnormal screening thoracic radiographs are more likely in dogs with an elevated lactate and cats with anemia, or a low normal hematocrit. © 2017 American College of Veterinary Radiology.

  4. Tarsal navicular stress fractures: radiographic evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pavlov, H.; Torg, J.S.; Freiberger, R.H.

    1983-09-01

    Tarsal navicular stress fractures are a potential source of disabling foot pain in physically active individuals. The diagnosis of tarsal navicular stress fracture requires a high index of clinical and radiographic suspicion because the fracture is only rarely evident on routine radiographs or standard tomograms. The radiographic diagnosis of a tarsal navicular stress fracture may require anatomic anteroposterior tomograms or a radionuclide bone scan with plantar views. Radiographic examinations of 23 fractures in 21 patients are evaluated.

  5. The relationship between operative and radiographic acetabular component orientation: which factors influence resultant cup orientation?

    PubMed

    Grammatopoulos, G; Pandit, H G; da Assunção, R; McLardy-Smith, P; De Smet, K A; Gill, H S; Murray, D W

    2014-10-01

    There is great variability in acetabular component orientation following hip replacement. The aims of this study were to compare the component orientation at impaction with the orientation measured on post-operative radiographs and identify factors that influence the difference between the two. A total of 67 hip replacements (52 total hip replacements and 15 hip resurfacings) were prospectively studied. Intra-operatively, the orientation of the acetabular component after impaction relative to the operating table was measured using a validated stereo-photogrammetry protocol. Post-operatively, the radiographic orientation was measured; the mean inclination/anteversion was 43° (sd 6°)/ 19° (sd 7°). A simulated radiographic orientation was calculated based on how the orientation would have appeared had an on-table radiograph been taken intra-operatively. The mean difference between radiographic and intra-operative inclination/anteversion was 5° (sd 5°)/ -8° (sd 8°). The mean difference between simulated radiographic and intra-operative inclination/anteversion, which quantifies the effect of the different way acetabular orientation is measured, was 3°/-6° (sd 2°). The mean difference between radiographic and simulated radiographic orientation inclination/anteversion, which is a manifestation of the change in pelvic position between component impaction and radiograph, was 1°/-2° (sd 7°). This study demonstrated that in order to achieve a specific radiographic orientation target, surgeons should implant the acetabular component 5° less inclined and 8° more anteverted than their target. Great variability (2 sd about ± 15°) in the post-operative radiographic cup orientation was seen. The two equally contributing causes for this are variability in the orientation at which the cup is implanted, and the change in pelvic position between impaction and post-operative radiograph. ©2014 The British Editorial Society of Bone & Joint Surgery.

  6. Clinical decision making using teleradiology in urology.

    PubMed

    Lee, B R; Allaf, M; Moore, R; Bohlman, M; Wang, G M; Bishoff, J T; Jackman, S V; Cadeddu, J A; Jarrett, T W; Khazan, R; Kavoussi, L R

    1999-01-01

    Using a personal computer-based teleradiology system, we compared accuracy, confidence, and diagnostic ability in the interpretation of digitized radiographs to determine if teleradiology-imported studies convey sufficient information to make relevant clinical decisions involving urology. Variables of diagnostic accuracy, confidence, image quality, interpretation, and the impact of clinical decisions made after viewing digitized radiographs were compared with those of original radiographs. We evaluated 956 radiographs that included 94 IV pyelograms, four voiding cystourethrograms, and two nephrostograms. The radiographs were digitized and transferred over an Ethernet network to a remote personal computer-based viewing station. The digitized images were viewed by urologists and graded according to confidence in making a diagnosis, image quality, diagnostic difficulty, clinical management based on the image itself, and brief patient history. The hard-copy radiographs were then interpreted immediately afterward, and diagnostic decisions were reassessed. All analog radiographs were reviewed by an attending radiologist. Ninety-seven percent of the decisions made from the digitized radiographs did not change after reviewing conventional radiographs of the same case. When comparing the variables of clinical confidence, quality of the film on the teleradiology system versus analog films, and diagnostic difficulty, we found no statistical difference (p > .05) between the two techniques. Overall accuracy in interpreting the digitized images on the teleradiology system was 88% by urologists compared with that of the attending radiologist's interpretation of the analog radiographs. However, urologists detected findings on five (5%) analog radiographs that had been previously unreported by the radiologist. Viewing radiographs transmitted to a personal computer-based viewing station is an appropriate means of reviewing films with sufficient quality on which to base clinical decisions. Our focus was whether decisions made after viewing the transmitted radiographs would change after viewing the hard-copy images of the same case. In 97% of the cases, the decision did not change. In those cases in which management was altered, recommendation of further imaging studies was the most common factor.

  7. 21 CFR 892.1870 - Radiographic film/cassette changer programmer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiographic film/cassette changer programmer. 892... SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1870 Radiographic film/cassette changer programmer. (a) Identification. A radiographic film/cassette changer programmer is a...

  8. 21 CFR 892.1870 - Radiographic film/cassette changer programmer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiographic film/cassette changer programmer. 892... SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1870 Radiographic film/cassette changer programmer. (a) Identification. A radiographic film/cassette changer programmer is a...

  9. 21 CFR 892.1870 - Radiographic film/cassette changer programmer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiographic film/cassette changer programmer. 892... SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1870 Radiographic film/cassette changer programmer. (a) Identification. A radiographic film/cassette changer programmer is a...

  10. 21 CFR 892.1870 - Radiographic film/cassette changer programmer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiographic film/cassette changer programmer. 892... SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1870 Radiographic film/cassette changer programmer. (a) Identification. A radiographic film/cassette changer programmer is a...

  11. 21 CFR 892.1870 - Radiographic film/cassette changer programmer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film/cassette changer programmer. 892... SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1870 Radiographic film/cassette changer programmer. (a) Identification. A radiographic film/cassette changer programmer is a...

  12. Influence of Radiographic Positioning on Canine Sacroiliac and Lumbosacral Angle Measurements.

    PubMed

    Jones, Susan; Savage, Mason; Naughton, Brian; Singh, Susheela; Robertson, Ian; Roe, Simon C; Marcellin-Little, Denis J; Mathews, Kyle G

    2018-01-01

     To evaluate the influence of radiographic malpositioning on canine sacroiliac and lumbosacral inclination angles.  Using canine cadavers, lateral pelvic radiographs were acquired with the radiographic beam in a neutral position and then rotated 5, 10 and 15° to mimic rotational malpositioning. The focal point of the beam was then focused over the abdomen and again over mid-diaphysis of the femur to mimic an abdominal or femoral radiographic study.  Five degrees of rotational malpositioning did not influence measurements of sacroiliac or lumbosacral inclination, but malpositioning by more than 5° led to a significant decrease in both sacroiliac and lumbosacral angles. Moving the focal point to the femur significantly decreased the measured lumbosacral angle. Abdominally centred radiographs had no effect on lumbosacral and sacroiliac angle measurements.  When evaluating canine lumbosacral and sacroiliac angles radiographically, pelvic rotation of more than 5° should be avoided as should the use of lateral radiographs centred over the femur. Schattauer GmbH Stuttgart.

  13. Magnification of digital hip radiographs differs between clinical workplaces.

    PubMed

    Hornová, Jana; Růžička, Pavel; Hrubina, Maroš; Šťastný, Eduard; Košková, Andrea; Fulín, Petr; Gallo, Jiří; Daniel, Matej

    2017-01-01

    Preoperative planning for total hip arthroplasty includes templating on anteroposterior radiographs. It is necessary to consider radiographic magnification in order to scale templates accurately. Studies dealing with hip templating report different values of radiographic magnification. It is not clear if the observed difference in magnification between the studies is caused by variability in studied groups, methodology or instrumentation. We hypothesize that there is a difference in magnification between clinical workplaces. Within this study, radiographic magnification was estimated on 337 radiographs of patients after total hip surgery from five orthopaedic departments in the Czech Republic. Magnification was determined for each patient as a ratio between diameter of implanted femoral head measured on radiogram and its true size. One-way ANOVA revealed significant differences in magnification between workplaces (F(4,332) = 132, p≤0.001). These results suggest that radiographic magnification depends on the workplace where it is taken or more precisely on radiographic device. It indicates potential limits in generalizability of results of studies dealing with preoperative planning accuracy to other institutions.

  14. The utility of plain radiographs in the initial evaluation of knee pain amongst sports medicine patients.

    PubMed

    Alaia, Michael J; Khatib, Omar; Shah, Mehul; A Bosco, Joseph; M Jazrawi, Laith; Strauss, Eric J

    2015-08-01

    To evaluate whether screening radiographs as part of the initial workup of knee pain impacts clinical decision-making in a sports medicine practice. A questionnaire was completed by the attending orthopaedic surgeon following the initial office visit for 499 consecutive patients presenting to the sports medicine centre with a chief complaint of knee pain. The questionnaire documented patient age, duration of symptoms, location of knee pain, associated mechanical symptoms, history of trauma within the past 2 weeks, positive findings on plain radiographs, whether magnetic resonance imaging was ordered, and whether plain radiographs impacted the management decisions for the patient. Patients were excluded if they had prior X-rays, history of malignancy, ongoing pregnancy, constitutional symptoms as well as those patients with prior knee surgery or intra-articular infections. Statistical analyses were then performed to determine which factors were more likely do correspond with diagnostic radiographs. Overall, initial screening radiographs did not change management in 72 % of the patients assessed in the office. The mean age of patients in whom radiographs did change management was 57.9 years compared to 37.1 years in those patients where plain radiograph did not change management (p < 0.0001). Plain radiographs had no impact on clinical management in 97.3 % of patients younger than 40. In patients whom radiographs did change management, radiographs were more likely to influence management if patients were over age forty, had pain for over 6 months, had medial or diffuse pain, or had mechanical symptoms. A basic cost analysis revealed that the cost of a clinically useful radiographic series in a patient under 40 years of age was $7,600, in contrast to $413 for a useful series in patients above the age of 40. Data from the current study support the hypothesis that for the younger patient population, routine radiographic imaging as a screening tool may be of little clinical benefit. Factors supporting obtaining screening radiographs include age greater than 40, knee pain for greater than 6 months, the presence of medial or diffuse knee pain, and the presence of mechanical symptoms. II.

  15. Kodak T-Mat G film in rotational panoramic radiography.

    PubMed

    Ponce, A Z; McDavid, W D; Lundeen, R C; Morris, C R

    1986-06-01

    Panoramic radiographs were taken of a tissue-equivalent phantom to evaluate T-Mat G and Ortho G films in combination with rare earth screens. The radiographs were compared to radiographs made with high-speed calcium tungstate screens and Kodak XRP film. The reduction in the amount of radiation necessary for the use of rare earth screens (50% to 70%) was accomplished by lowering the mA and adding filtration. All evaluated films were diagnostically acceptable. There was a marked preference of the T-Mat radiographs over the Ortho G radiographs and a slight preference over radiographs made with the standard calcium-tungstate screen-film system.

  16. 21 CFR 892.1900 - Automatic radiographic film processor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automatic radiographic film processor. 892.1900... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1900 Automatic radiographic film processor. (a) Identification. An automatic radiographic film processor is a device intended to be used to...

  17. 21 CFR 892.1890 - Radiographic film illuminator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiographic film illuminator. 892.1890 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator. (a) Identification. A radiographic film illuminator is a device containing a visible light source covered with a...

  18. 21 CFR 892.1890 - Radiographic film illuminator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiographic film illuminator. 892.1890 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator. (a) Identification. A radiographic film illuminator is a device containing a visible light source covered with a...

  19. 21 CFR 892.1900 - Automatic radiographic film processor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automatic radiographic film processor. 892.1900... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1900 Automatic radiographic film processor. (a) Identification. An automatic radiographic film processor is a device intended to be used to...

  20. 21 CFR 892.1890 - Radiographic film illuminator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiographic film illuminator. 892.1890 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator. (a) Identification. A radiographic film illuminator is a device containing a visible light source covered with a...

  1. 21 CFR 892.1900 - Automatic radiographic film processor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automatic radiographic film processor. 892.1900... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1900 Automatic radiographic film processor. (a) Identification. An automatic radiographic film processor is a device intended to be used to...

  2. 21 CFR 892.1890 - Radiographic film illuminator.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiographic film illuminator. 892.1890 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator. (a) Identification. A radiographic film illuminator is a device containing a visible light source covered with a...

  3. 21 CFR 892.1900 - Automatic radiographic film processor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automatic radiographic film processor. 892.1900... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1900 Automatic radiographic film processor. (a) Identification. An automatic radiographic film processor is a device intended to be used to...

  4. 21 CFR 892.1890 - Radiographic film illuminator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film illuminator. 892.1890 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator. (a) Identification. A radiographic film illuminator is a device containing a visible light source covered with a...

  5. 21 CFR 892.1900 - Automatic radiographic film processor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automatic radiographic film processor. 892.1900... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1900 Automatic radiographic film processor. (a) Identification. An automatic radiographic film processor is a device intended to be used to...

  6. Three-dimensional images contribute to the diagnosis of mucous retention cyst in maxillary sinus

    PubMed Central

    Donizeth-Rodrigues, Cleomar; Fonseca-Da Silveira, Márcia; Gonçalves-De Alencar, Ana H.; Garcia-Santos-Silva, Maria A.; Francisco-De-Mendonça, Elismauro

    2013-01-01

    Objective: To evaluate the detection of mucous retention cyst of maxillary sinus (MRCMS) using panoramic radiography and cone beam computed tomography (CBCT). Study Design: A digital database with 6,000 panoramic radiographs was reviewed for MRCMS. Suggestive images of MRCMS were detected on 185 radiographs, and patients were located and invited to return for follow-up. Thirty patients returned, and control panoramic radiographs were obtained 6 to 46 months after the initial radiograph. When MRCMS was found on control radiographs, CBCT scans were obtained. Cysts were measured and compared on radiographs and scans. The Wilcoxon, Spearman and Kolmorogov-Smirnov tests were used for statistical analysis. The level of significance was set at 5%. Results: There were statistically significant differences between the two methods (p<0.05): 23 MRCMS detected on panoramic radiographs were confirmed by CBCT, but 5 MRCMS detected on CBCT images had not been identified by panoramic radiography. Eight MRCMS detected on control radiographs were not confirmed by CBCT. MRCMS size differences from initial to control panoramic radiographs and CBCT scans were not statistically significant (p= 0.617 and p= 0.626). The correlation between time and MRCMS size differences was not significant (r = -0.16, p = 0.381). Conclusion: CBCT scanning detect MRCMS more accurately than panoramic radiography. Key words:Mucous cyst, maxillary sinus, panoramic radiograph, cone beam computed tomography. PMID:23229251

  7. High-energy (> 70 KeV) x-ray conversion efficiency measurement on the ARC laser at the National Ignition Facility

    DOE PAGES

    Chen, Hui; Hermann, M. R.; Kalantar, D. H.; ...

    2017-03-16

    Here, the Advanced Radiographic Capability (ARC) laser system at the National Ignition Facility (NIF) is designed to ultimately provide eight beamlets with a pulse duration adjustable from 1 to 30 ps, and energies up to 1.5 kJ per beamlet. Currently, four beamlets have been commissioned. In the first set of 6 commissioning target experiments, the individual beamlets were fired onto gold foil targets with energy up to 1 kJ per beamlet at 20–30 ps pulse length. The x-ray energy distribution and pulse duration were measured, yielding energy conversion efficiencies of 4–9 × 10 –4 for x-rays with energies greater thanmore » 70 keV. With greater than 3 J of such x-rays, ARC provides a high-precision x-ray backlighting capability for upcoming inertial confinement fusion and high-energy-density physics experiments on NIF.« less

  8. [Radiographic findings in raptors affected with a mycosis of the respiratory tract].

    PubMed

    Vorbrüggen, S; Bailey, T; Krautwald-Junghanns, M-E

    2013-01-01

    Summary of typical radiographic signs in birds of prey with aspergillosis compared to signs previously established in parrots. Evaluation of radiographs of 110 falcons (Falco spp.) with aspergillosis confirmed by endoscopy. Compared to parrots primarily subtle radiographic signs were detected in falcons (especially inhomogeneously increased radiodensities of the airsacs/lungs). Two typical signs for diseased falcons consisted of the poor delineation of the cardiac silhouette and the line-shaped increased radiodensity of the caudal lung border. Radiographic diagnosis of the lung is limited due to the strong flight musculature. The varying results between avian species can be explained by the different radiographic anatomy, husbandry conditions and x-ray technique (digital versus analog). A pet bird-experienced practitioner should be aware of specific radiographic signs in birds of prey suspected of having aspergillosis.

  9. Effect of localizer radiograph on radiation dose associated with automatic exposure control: human cadaver and patient study.

    PubMed

    Singh, Sarabjeet; Petrovic, Dean; Jamnik, Ethen; Aran, Shima; Pourjabbar, Sarvenaz; Kave, Maggie L; Bradley, Stephen E; Choy, Garry; Kalra, Mannudeep K

    2014-01-01

    To evaluate the effect of localizing radiograph on computed tomography (CT) radiation dose associated with automatic exposure control with a human cadaver and patient study. Institutional review board approved the study with a waiver of informed consent. Two chest CT image series with fixed tube current and combined longitudinal-angular automatic exposure control (AEC) were acquired in a human cadaver (64-year-old man) after each of the 8 combinations of localizer radiographs (anteroposterior [AP], AP lateral, AP-posteroanterior [PA], lateral AP, lateral PA, PA, PA-AP, and PA lateral). Applied effective milliampere second, volume CT dose index (CTDIvol) and image noise were recorded for all 24-image series. Volume CT dose indexes were also recorded in 20 patients undergoing chest and abdominal CT after PA and PA-lateral radiographs with the use of AEC. Data were analyzed using analysis of variance and linear correlation tests. With AEC, the CTDIvol fluctuates with the number and projection of localizer radiographs (P < 0.0001). Lowest CTDIvol values are seen when 2 orthogonal localizer radiographs are acquired, whereas highest values are seen when single PA or AP-PA projection localizer radiographs are acquired for planning (P < 0.0001). In 20 patients, CT scanning with AEC after acquisition of 2 orthogonal projection localizer radiographs was associated with significant reduction in radiation dose compared to PA projection radiographs alone (P < 0.0001). When scanning with AEC, acquisition of 2 orthogonal localizer radiographs is associated with lower CTDIvol compared to a single localizer radiograph.

  10. Usefulness of Chest Radiographs for Scoliosis Screening: A Comparison with Thoraco-Lumbar Standing Radiographs

    PubMed Central

    Oh, Chang Hyun; Kim, Chan Gyu; Lee, Myoung Seok; Park, Hyeong-Chun; Park, Chong Oon

    2012-01-01

    Purpose The purposes of this study were to evaluate the usefulness and limitations of chest radiographs in scoliosis screening and to compare these results with those of thoraco-lumbar standing radiographs (TLSR). Materials and Methods During Korean conscription, 419 males were retrospectively examined using both chest radiographs and TLSR to confirm the scoliosis and Cobb angle at the Regional Military Manpower. We compared the types of spinal curves and Cobb angles as measured from different radiographs. Results In the pattern of spinal curves, the overall matching rate of chest radiographs using TLSR was about 58.2% (244 of 419 cases). Cobb angle differences between chest radiographs and TLSR with meaningful difference was observed in 156 cases (37.2%); a relatively high proportion (9.5%) of Cobb angle differences more than 10 degrees was also observed. The matching rate of both spinal curve types and Cobb angle accuracy between chest radiographs and TLSR was 27.9% (117 among 419 cases). Chest radiographs for scoliosis screening were observed with 93.94% of sensitivity and 61.67% of specificity in thoracic curves; however, less than 40% of sensitivity (38.27%, 20.00%, and 25.80%) and more than 95% of specificity (97.34%, 99.69%, and 98.45%) were observed in thoraco-lumbar, lumbar, and double major curves, respectively. Conclusion The accuracy of chest radiographs for scoliosis screening was low. The incidence of thoracic curve scoliosis was overestimated and lumbar curve scoliosis was easily missed by chest radiography. Scoliosis screening using chest radiography has limited values, nevertheless, it is useful method for detecting thoracic curve scoliosis. PMID:23074120

  11. 21 CFR 892.1850 - Radiographic film cassette.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiographic film cassette. 892.1850 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1850 Radiographic film cassette. (a) Identification. A radiographic film cassette is a device intended for use during diagnostic x-ray procedures to...

  12. 42 CFR 37.50 - Interpreting and classifying chest radiographs-film.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Interpreting and classifying chest radiographs-film. 37.50 Section 37.50 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Radiographs § 37.50 Interpreting and classifying chest radiographs—film. (a) Chest radiographs must be...

  13. 21 CFR 892.1860 - Radiographic film/cassette changer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiographic film/cassette changer. 892.1860... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1860 Radiographic film/cassette changer. (a) Identification. A radiographic film/cassette changer is a device intended to be used during a...

  14. 21 CFR 892.1840 - Radiographic film.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiographic film. 892.1840 Section 892.1840 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a) Identification. Radiographic film is a device that consists of a thin sheet of radiotransparent material coated on one or both...

  15. 21 CFR 892.1850 - Radiographic film cassette.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiographic film cassette. 892.1850 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1850 Radiographic film cassette. (a) Identification. A radiographic film cassette is a device intended for use during diagnostic x-ray procedures to...

  16. 21 CFR 892.1840 - Radiographic film.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiographic film. 892.1840 Section 892.1840 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a) Identification. Radiographic film is a device that consists of a thin sheet of radiotransparent material coated on one or both...

  17. 21 CFR 892.1860 - Radiographic film/cassette changer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiographic film/cassette changer. 892.1860... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1860 Radiographic film/cassette changer. (a) Identification. A radiographic film/cassette changer is a device intended to be used during a...

  18. 21 CFR 892.1640 - Radiographic film marking system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiographic film marking system. 892.1640 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1640 Radiographic film marking system. (a) Identification. A radiographic film marking system is a device intended for medical purposes to...

  19. 21 CFR 892.1860 - Radiographic film/cassette changer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiographic film/cassette changer. 892.1860... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1860 Radiographic film/cassette changer. (a) Identification. A radiographic film/cassette changer is a device intended to be used during a...

  20. 21 CFR 892.1640 - Radiographic film marking system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiographic film marking system. 892.1640 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1640 Radiographic film marking system. (a) Identification. A radiographic film marking system is a device intended for medical purposes to...

  1. 21 CFR 892.1840 - Radiographic film.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiographic film. 892.1840 Section 892.1840 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a) Identification. Radiographic film is a device that consists of a thin sheet of radiotransparent material coated on one or both...

  2. 21 CFR 892.1640 - Radiographic film marking system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiographic film marking system. 892.1640 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1640 Radiographic film marking system. (a) Identification. A radiographic film marking system is a device intended for medical purposes to...

  3. 21 CFR 892.1850 - Radiographic film cassette.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiographic film cassette. 892.1850 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1850 Radiographic film cassette. (a) Identification. A radiographic film cassette is a device intended for use during diagnostic x-ray procedures to...

  4. 21 CFR 892.1840 - Radiographic film.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiographic film. 892.1840 Section 892.1840 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a) Identification. Radiographic film is a device that consists of a thin sheet of radiotransparent material coated on one or both...

  5. 21 CFR 892.1860 - Radiographic film/cassette changer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiographic film/cassette changer. 892.1860... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1860 Radiographic film/cassette changer. (a) Identification. A radiographic film/cassette changer is a device intended to be used during a...

  6. 21 CFR 892.1640 - Radiographic film marking system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiographic film marking system. 892.1640 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1640 Radiographic film marking system. (a) Identification. A radiographic film marking system is a device intended for medical purposes to...

  7. 21 CFR 892.1850 - Radiographic film cassette.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film cassette. 892.1850 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1850 Radiographic film cassette. (a) Identification. A radiographic film cassette is a device intended for use during diagnostic x-ray procedures to...

  8. 21 CFR 892.1640 - Radiographic film marking system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film marking system. 892.1640 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1640 Radiographic film marking system. (a) Identification. A radiographic film marking system is a device intended for medical purposes to...

  9. 21 CFR 892.1860 - Radiographic film/cassette changer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film/cassette changer. 892.1860... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1860 Radiographic film/cassette changer. (a) Identification. A radiographic film/cassette changer is a device intended to be used during a...

  10. 21 CFR 892.1840 - Radiographic film.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film. 892.1840 Section 892.1840 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a) Identification. Radiographic film is a device that consists of a thin sheet of radiotransparent material coated on one or both...

  11. Is there a relation between local bone quality as assessed on panoramic radiographs and alveolar bone level?

    PubMed

    Nackaerts, Olivia; Gijbels, Frieda; Sanna, Anna-Maria; Jacobs, Reinhilde

    2008-03-01

    The aim was to explore the relation between radiographic bone quality on panoramic radiographs and relative alveolar bone level. Digital panoramic radiographs of 94 female patients were analysed (mean age, 44.5; range, 35-74). Radiographic density of the alveolar bone in the premolar region was determined using Agfa Musica software. Alveolar bone level and bone quality index (BQI) were also assessed. Relationships between bone density and BQI on one hand and the relative loss of alveolar bone level on the other were assessed. Mandibular bone density and loss of alveolar bone level were weakly but significantly negatively correlated for the lower premolar area (r = -.27). The BQI did not show a statistically significant relation to alveolar bone level. Radiographic mandibular bone density on panoramic radiographs shows a weak but significant relation to alveolar bone level, with more periodontal breakdown for less dense alveolar bone.

  12. Measurement of lung volumes from supine portable chest radiographs.

    PubMed

    Ries, A L; Clausen, J L; Friedman, P J

    1979-12-01

    Lung volumes in supine nonambulatory patients are physiological parameters often difficult to measure with current techniques (plethysmograph, gas dilution). Existing radiographic methods for measuring lung volumes require standard upright chest radiographs. Accordingly, in 31 normal supine adults, we determined helium-dilution functional residual and total lung capacities and measured planimetric lung field areas (LFA) from corresponding portable anteroposterior and lateral radiographs. Low radiation dose methods, which delivered less than 10% of that from standard portable X-ray technique, were utilized. Correlation between lung volume and radiographic LFA was highly significant (r = 0.96, SEE = 10.6%). Multiple-step regressions using height and chest diameter correction factors reduced variance, but weight and radiographic magnification factors did not. In 17 additional subjects studied for validation, the regression equations accurately predicted radiographic lung volume. Thus, this technique can provide accurate and rapid measurement of lung volume in studies involving supine patients.

  13. The usage of image trigonometry in bone measurements.

    PubMed

    Dymond, Ian W; Ashforth, James A; Dymond, Graeme F; Spirakis, Thanos; Learmonth, Ian D

    2013-01-01

    The entire musculo-skeletal system responds dynamically to stresses and strains applied to it. Restoring normal biomechanics contributes to the normal function that ensures that physiological stresses and strains are preserved. Appropriate preoperative planning is mandatory to restore normal biomechanics at reconstructive surgery. Effective preoperative planning depends on the ability to reproducibly make accurate measurements of lengths and angles from plain radiographs. Measurement has become an integral part of orthopaedics to define morphological abnormality, to plan for reconstruction and for comparative research. The most prevalent method of measurement is usually based on lines drawn on radiographs with no accurate reference to the actual geometry of the structures. This two-dimensional projection of an asymmetrical three-dimensional structure leads to inaccuracy and consequently to a compromise in the overall precision of many procedures. In addition it is also difficult to monitor the progression of disease as the exact relationship of the bones and joints to each other, and to prosthetics, cannot be accurately recorded. This paper presents a method of digitally measuring relevant bone parameters in a geometric manner in order to achieve accurate, repeatable measurements.

  14. Radiographic anatomy of the foot and ankle—part 4: the metatarsals.

    PubMed

    Christman, Robert A

    2015-01-01

    The normal radiographic anatomy of the foot and ankle, aside from my previous work, has been addressed only superficially or sparingly in the medical literature. This project correlates the detailed radiographic anatomy of the entire adult foot and ankle (two-dimensional) to osteology (three-dimensional). Each bone's position was determined after meticulous examination and correlation to an articulated skeleton relative to the image receptor and direction of the x-ray beam, with correlation to the radiograph for confirmation. Images of each foot and distal leg bone ("front" and "back" perspectives) are presented alongside a corresponding radiographic image for comparison. The normal gross and radiographic anatomy is correlated and described for each radiographic positioning technique. Foundational knowledge is provided that future researchers can use as a baseline ("normal") and that students and practitioners can use for comparison when interpreting radiographs and distinguishing abnormal findings. The results of the original project, owing to its broad scope, have been divided into five parts: the lower leg, the greater tarsus, the lesser tarsus, the metatarsals (the focus of this article), and the phalanges.

  15. Radiographic anatomy of the foot and ankle-part 5. The phalanges.

    PubMed

    Christman, Robert A

    2015-03-01

    The normal radiographic anatomy of the foot and ankle, aside from my previous work, has been addressed only superficially or sparingly in the medical literature. This project correlates the detailed radiographic anatomy of the entire adult foot and ankle (two-dimensional) to osteology (three-dimensional). Each bone's position was determined after meticulous examination and correlation to an articulated skeleton relative to the image receptor and direction of the x-ray beam, with correlation to the radiograph for confirmation. Images of each foot and distal leg bone ("front" and "back" perspectives) are presented alongside a corresponding radiographic image for comparison. The normal gross and radiographic anatomy is correlated and described for each radiographic positioning technique. Foundational knowledge is provided that future researchers can use as a baseline ("normal") and that students and practitioners can use for comparison when interpreting radiographs and distinguishing abnormal findings. The results of the original project, owing to its broad scope, have been divided into five parts: the lower leg, the greater tarsus, the lesser tarsus, the metatarsals, and the phalanges (the focus of this article).

  16. Radiographic anatomy of the foot and ankle-part 2: the greater tarsus.

    PubMed

    Christman, Robert A

    2014-01-01

    Normal radiographic anatomy of the foot and ankle, aside from my previous work, has been addressed only superficially or sparingly in the medical literature. This project correlates detailed radiographic anatomy of the entire adult foot and ankle (two-dimensional) to osteology (three-dimensional). Each bone's position was determined after meticulous examination and correlation to an articulated skeleton relative to the image receptor and direction of the x-ray beam, with correlation to the radiograph for confirmation. Images of each foot and distal leg bone ("front" and "back" perspectives) are presented alongside a corresponding radiographic image for comparison. The normal gross and radiographic anatomy is correlated and described for each radiographic positioning technique. Foundational knowledge is provided that future researchers can use as a baseline ("normal") and that students and practitioners can use for comparison when interpreting radiographs and distinguishing abnormal findings. The results of the original project, owing to its broad scope, have been divided into five parts: the lower leg, the greater tarsus (the focus of this article), the lesser tarsus, the metatarsals, and the phalanges.

  17. Can the tibial slope be measured on lateral knee radiographs?

    PubMed

    Faschingbauer, M; Sgroi, M; Juchems, M; Reichel, H; Kappe, T

    2014-12-01

    The posterior tibial slope influences both the natural knee stability as well as the stability and kinematics after total knee arthroplasty (TKA). Exact definition of the posterior tibial slope (PTS) requires lateral radiographs of the lower limb. Only lateral knee radiographs are routinely obtained after TKA, however. The purpose of the present study therefore was to analyse the relationship between PTS measurement results on short and expanded lateral knee radiographs. The PTS was measured on 100 consecutive lateral radiographs of the lower limb using the mechanical and three diaphyseal axes with various distances below the tibial plateau. Significant differences between PTS results were found for all three diaphyseal axes, with the smallest differences and the strongest correlation for a diaphyseal axis at 16 and 20 cm below the tibial plateau. Using short distances below the tibial plateau (6 and 10 cm) resulted in an overestimation of the PTS of 3°, on average. The PTS measurements in long lateral knee radiographs are more accurate compared to short radiographs. On short lateral knee radiographs, only a estimation of the PTS can be carried out. Diagnostic study, Level II.

  18. An in-vitro comparison of the radiographic and actual gutta-percha terminus.

    PubMed

    Namazikhah, M S; Ghiai, M; Parkin, M J; Puccinelli, L

    2000-06-01

    The purpose of this study was to investigate the difference between the radiographic gutta-percha terminus and the actual gutta-percha terminus of human molars by comparing radiographic obturation results with actual obturation results. Forty maxillary palatal roots and 50 mandibular distal roots were randomly selected from a population of 540. They were then mounted in stone and radiographed. Conventional endodontic therapy was completed using stainless-steel K files and lateral condensation. Each radiographic gutta-percha terminus was evaluated under 4.5x magnification by three examiners following the completion of root canal therapy. These results were recorded. Each tooth was then removed from its mounting, and the actual gutta-percha terminus was evaluated under 4.5x magnification. These results were recorded and compared to the radiographic gutta-percha terminus results. In all 90 teeth examined, the actual gutta-percha terminus was equal to or longer than the radiographic gutta-percha terminus. In the 50 mandibular distal roots, the actual gutta-percha terminus averaged 0.645 mm longer than the radiographic gutta-percha terminus. In the 40 maxillary palatal roots, this difference measured 0.6375 mm.

  19. Dynamic malware analysis using IntroVirt: a modified hypervisor-based system

    NASA Astrophysics Data System (ADS)

    White, Joshua S.; Pape, Stephen R.; Meily, Adam T.; Gloo, Richard M.

    2013-05-01

    In this paper, we present a system for Dynamic Malware Analysis which incorporates the use of IntroVirt™. IntroVirt is an introspective hypervisor architecture and infrastructure that supports advanced analysis techniques for stealth-malwareanalysis. This system allows for complete guest monitoring and interaction, including the manipulation and blocking of system calls. IntroVirt is capable of bypassing virtual machine detection capabilities of even the most sophisticated malware, by spoofing returns to system call responses. Additional fuzzing capabilities can be employed to detect both malware vulnerabilities and polymorphism.

  20. Three-dimensional images contribute to the diagnosis of mucous retention cyst in maxillary sinus.

    PubMed

    Donizeth-Rodrigues, Cleomar; Fonseca-Da Silveira, Márcia; Gonçalves-De Alencar, Ana-Helena; Garcia-Santos-Silva, Maria-Alves; Francisco-De-Mendonça, Elismauro; Estrela, Carlos

    2013-01-01

    To evaluate the detection of mucous retention cyst of maxillary sinus (MRCMS) using panoramic radiography and cone beam computed tomography (CBCT). A digital database with 6,000 panoramic radiographs was reviewed for MRCMS. Suggestive images of MRCMS were detected on 185 radiographs, and patients were located and invited to return for follow-up. Thirty patients returned, and control panoramic radiographs were obtained 6 to 46 months after the initial radiograph. When MRCMS was found on control radiographs, CBCT scans were obtained. Cysts were measured and compared on radiographs and scans. The Wilcoxon, Spearman and Kolmorogov-Smirnov tests were used for statistical analysis. The level of significance was set at 5%. There were statistically significant differences between the two methods (p<0.05): 23 MRCMS detected on panoramic radiographs were confirmed by CBCT, but 5 MRCMS detected on CBCT images had not been identified by panoramic radiography. Eight MRCMS detected on control radiographs were not confirmed by CBCT. MRCMS size differences from initial to control panoramic radiographs and CBCT scans were not statistically significant (p= 0.617 and p= 0.626). The correlation between time and MRCMS size differences was not significant (r = -0.16, p = 0.381). CBCT scanning detect MRCMS more accurately than panoramic radiography.

  1. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images.

    PubMed

    Suojärvi, Nora; Sillat, T; Lindfors, N; Koskinen, S K

    2015-12-01

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities.

  2. Validation of a new radiographic protocol for Asian elephant feet and description of their radiographic anatomy.

    PubMed

    Mumby, C; Bouts, T; Sambrook, L; Danika, S; Rees, E; Parry, A; Rendle, M; Masters, N; Weller, R

    2013-10-05

    Foot problems are extremely common in elephants and radiography is the only imaging method available but the radiographic anatomy has not been described in detail. The aims of this study were to develop a radiographic protocol for elephant feet using digital radiography, and to describe the normal radiographic anatomy of the Asian elephant front and hind foot. A total of fifteen cadaver foot specimens from captive Asian elephants were radiographed using a range of projections and exposures to determine the best radiographic technique. This was subsequently tested in live elephants in a free-contact setting. The normal radiographic anatomy of the Asian elephant front and hind foot was described with the use of three-dimensional models based on CT reconstructions. The projection angles that were found to be most useful were 65-70° for the front limb and 55-60° in the hind limb. The beam was centred 10-15 cm proximal to the cuticle in the front and 10-15 cm dorsal to the plantar edge of the sole in the hind foot depending on the size of the foot. The protocol developed can be used for larger-scale diagnostic investigations of captive elephant foot disorders, while the normal radiographic anatomy described can improve the diagnostic reliability of elephant feet radiography.

  3. A mathematical method for precisely calculating the radiographic angles of the cup after total hip arthroplasty.

    PubMed

    Zhao, Jing-Xin; Su, Xiu-Yun; Xiao, Ruo-Xiu; Zhao, Zhe; Zhang, Li-Hai; Zhang, Li-Cheng; Tang, Pei-Fu

    2016-11-01

    We established a mathematical method to precisely calculate the radiographic anteversion (RA) and radiographic inclination (RI) angles of the acetabular cup based on anterior-posterior (AP) pelvic radiographs after total hip arthroplasty. Using Mathematica software, a mathematical model for an oblique cone was established to simulate how AP pelvic radiographs are obtained and to address the relationship between the two-dimensional and three-dimensional geometry of the opening circle of the cup. In this model, the vertex was the X-ray beam source, and the generatrix was the ellipse in radiographs projected from the opening circle of the acetabular cup. Using this model, we established a series of mathematical formulas to reveal the differences between the true RA and RI cup angles and the measurements results achieved using traditional methods and AP pelvic radiographs and to precisely calculate the RA and RI cup angles based on post-operative AP pelvic radiographs. Statistical analysis indicated that traditional methods should be used with caution if traditional measurements methods are used to calculate the RA and RI cup angles with AP pelvic radiograph. The entire calculation process could be performed by an orthopedic surgeon with mathematical knowledge of basic matrix and vector equations. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Supramolecular assembly/reassembly processes: molecular motors and dynamers operating at surfaces.

    PubMed

    Ciesielski, Artur; Samorì, Paolo

    2011-04-01

    Among the many significant advances within the field of supramolecular chemistry over the past decades, the development of the so-called "dynamers" features a direct relevance to materials science. Defined as "combinatorial dynamic polymers", dynamers are constitutional dynamic systems and materials resulting from the application of the principles of supramolecular chemistry to polymer science. Like supramolecular materials in general, dynamers are reversible dynamic multifunctional architectures, capable of modifying their constitution by exchanging, recombining, incorporating components. They may exhibit a variety of novel properties and behave as adaptive materials. In this review we focus on the design of responsive switchable monolayers, i.e. monolayers capable to undergo significant changes in their physical or chemical properties as a result of external stimuli. Scanning tunneling microscopy studies provide direct evidence with a sub-nanometre resolution, on the formation and dynamic response of these self-assembled systems featuring controlled geometries and properties.

  5. Radiographic protocol and normal anatomy of the hind feet in the white rhinoceros (Ceratotherium simum).

    PubMed

    Dudley, Robert J; Wood, Simon P; Hutchinson, John R; Weller, Renate

    2015-01-01

    Foot pathology is a common and important health concern in captive rhinoceroses worldwide, but osteopathologies are rarely diagnosed, partly because of a lack of radiographic protocols. Here, we aimed to develop the first radiographic protocol for rhinoceros feet and describe the radiographic anatomy of the white rhinoceros (Ceratotherium simum) hind foot (pes). Computed tomographic images were obtained of nine cadaver pedes from seven different white rhinoceroses and assessed for pathology. A single foot deemed free of pathology was radiographed using a range of different projections and exposures to determine the best protocol. 3D models were produced from the CT images and were displayed with the real radiographs to describe the normal radiographic anatomy of the white rhinoceros pes. An optimal radiographic projection was determined for each bone in the rhinoceros pes focusing on highlighting areas where pathology has been previously described. The projections deemed to be most useful were D60Pr-PlDiO (digit III), D45Pr45M-PlDiLO (digit II), and D40Pr35L-PlDiLO (digit IV). The primary beam was centered 5-7 cm proximal to the cuticle on the digit of interest. Articular surfaces, ridges, grooves, tubercles, processes and fossae were identified. The radiographic protocol we have developed along with the normal radiographic anatomy we have described will allow for more accessible and effective diagnosis of white rhinoceros foot osteopathologies. © 2014 American College of Veterinary Radiology.

  6. Radiographic features of cardiogenic pulmonary edema in dogs with mitral regurgitation: 61 cases (1998-2007).

    PubMed

    Diana, Alessia; Guglielmini, Carlo; Pivetta, Mauro; Sanacore, Antonina; Di Tommaso, Morena; Lord, Peter F; Cipone, Mario

    2009-11-01

    To evaluate radiographic distribution of pulmonary edema (PE) in dogs with mitral regurgitation (MR) and investigate the association between location of radiographic findings and direction of the mitral regurgitant jet (MRJ). Retrospective case series. 61 dogs with cardiogenic PE and MR resulting from mitral valve disease (MVD; 51 dogs), dilated cardiomyopathy (9), and hypertrophic cardiomyopathy (1). Thoracic radiographs of dogs with Doppler echocardiographic evidence of MR were reviewed for location (diffuse, perihilar, or focal) of PE. Also, direction (central or eccentric) of the MRJ, as evaluated by Doppler color flow mapping (DCFM), and distribution (symmetric or asymmetric) of radiographic findings were evaluated. Diffuse, perihilar, and focal increases in pulmonary opacity were observed in 11 (18.0%), 7 (11.5%), and 43 (70.5%) of 61 dogs, respectively. Radiographic evidence of asymmetric PE in a single lung lobe or 2 ipsilateral lobes was found in 21 dogs, with involvement of only the right caudal lung lobe in 17 dogs. Doppler color flow mapping of the MRJ was available for 46 dogs. Of 31 dogs with a central MRJ, 28 had radiographic findings indicative of symmetric PE. Of 15 dogs with eccentric MRJ, 11 had radiographic evidence of asymmetric PE, and all of these dogs had MVD. In dogs with cardiogenic PE, a symmetric radiographic distribution of increased pulmonary opacity was predominantly associated with a central MRJ, whereas an asymmetric radiographic distribution was usually associated with eccentric MRJ, especially in dogs with MVD.

  7. Radiographic identification of the anterior and posterior root attachments of the medial and lateral menisci.

    PubMed

    James, Evan W; LaPrade, Christopher M; Ellman, Michael B; Wijdicks, Coen A; Engebretsen, Lars; LaPrade, Robert F

    2014-11-01

    Anatomic root placement is necessary to restore native meniscal function during meniscal root repair. Radiographic guidelines for anatomic root placement are essential to improve the accuracy and consistency of anatomic root repair and to optimize outcomes after surgery. To define quantitative radiographic guidelines for identification of the anterior and posterior root attachments of the medial and lateral menisci on anteroposterior (AP) and lateral radiographic views. Descriptive laboratory study. The anterior and posterior roots of the medial and lateral menisci were identified in 12 human cadaveric specimens (average age, 51.3 years; age range, 39-65 years) and labeled using 2-mm radiopaque spheres. True AP and lateral radiographs were obtained, and 2 raters independently measured blinded radiographs in relation to pertinent landmarks and radiographic reference lines. On AP radiographs, the anteromedial and posteromedial roots were, on average, 31.9 ± 5.0 mm and 36.3 ± 3.5 mm lateral to the edge of the medial tibial plateau, respectively. The anterolateral and posterolateral roots were, on average, 37.9 ± 5.2 mm and 39.3 ± 3.8 mm medial to the edge of the lateral tibial plateau, respectively. On lateral radiographs, the anteromedial and anterolateral roots were, on average, 4.8 ± 3.7 mm and 20.5 ± 4.3 mm posterior to the anterior margin of the tibial plateau, respectively. The posteromedial and posterolateral roots were, on average, 18.0 ± 2.8 mm and 19.8 ± 3.5 mm anterior to the posterior margin of the tibial plateau, respectively. The intrarater and interrater intraclass correlation coefficients (ICCs) were >0.958, demonstrating excellent reliability. The meniscal root attachment sites were quantitatively and reproducibly defined with respect to anatomic landmarks and superimposed radiographic reference lines. The high ICCs indicate that the measured radiographic relationships are a consistent means for evaluating meniscal root positions. This study demonstrated consistent and reproducible radiographic guidelines for the location of the meniscal roots. These measurements may be used to assess root positions on intraoperative fluoroscopy and postoperative radiographs. © 2014 The Author(s).

  8. Are radiographs needed when MR imaging is performed for non-acute knee symptoms in patients younger than 45 years of age?

    PubMed Central

    ter Braak, Bert P. M.; van Erkel, Arian R.; Bloem, Rolf M.; Napoleon, L. J.; Coene, M. N.; van Luijt, Peter A.; de Lange, Sam; Bloem, Johan L.

    2007-01-01

    Objective The objective was to determine the value of radiographs in young adults with non-acute knee symptoms who are scheduled for magnetic resonance imaging (MRI). Materials and methods Nine hundred and sixty-one consecutive patients aged between 16 and 45 years with knee symptoms of at least 4 weeks’ duration were prospectively included in three participating hospitals. After applying exclusion criteria, 798 patients remained. Exclusion criteria were previous knee surgery (including arthroscopy) or MRI, history of rheumatoid arthritis, clinical diagnosis of retropatellar chondromalacia, contra-indication for MRI and recent trauma. We identified two groups: group A with no history of trauma (n = 332), and group B with an old (>4 weeks) history of trauma (n = 466). Patients had a standardized history taken, and underwent a physical exam, antero-posterior (AP) and lateral radiographs and MRI. We evaluated the radiographs and MRI for osseous lesions, articular surface lesions, fractures, osteoarthritis, loose bodies, bone marrow edema and incidental findings. Subsequently, patients with osseous abnormalities (Kellgren grade 1 and 2 excluded) on radiographs and a matched control group was evaluated again using MRI without radiographs. Results Median duration of symptoms was 20 weeks. In group A, radiographs showed 36 osseous abnormalities in 332 patients (10.8%). Only 13 of these, all Kellgren grade 1 osteoarthritis, were not confirmed on MRI. MRI showed 72 (21.7%) additional abnormalities not confirmed on radiographs. In group B, radiographs showed 40 osseous abnormalities (8.6%) in 466 patients. Only 15 of these, all Kellgren grade 1 osteoarthritis, were not confirmed on MRI. MRI showed 194 (41.6%) additional abnormalities not confirmed on radiographs. The second evaluation of MRI without radiographs in 34 patients was identical to the first MRI evaluation. Common lesions were significantly more often diagnosed with MRI than with radiographs. Conclusion Radiographs should not be obtained routinely when MRI is being performed in young adults with non-acute knee complaints because the yield and added value to MRI are low. PMID:17912515

  9. Association of hip pain with radiographic evidence of hip osteoarthritis: diagnostic test study

    PubMed Central

    Nevitt, Michael C; Niu, Jingbo; Clancy, Mary M; Lane, Nancy E; Link, Thomas M; Vlad, Steven; Tolstykh, Irina; Jungmann, Pia M.; Felson, David T; Guermazi, Ali

    2015-01-01

    Study question Is there concordance between hip pain and radiographic hip osteoarthritis? Methods In this diagnostic test study, pelvic radiographs were assessed for hip osteoarthritis in two cohorts: the Framingham Osteoarthritis Study (community of Framingham, Massachusetts) and the Osteoarthritis Initiative (a multicenter longitudinal cohort study of osteoarthritis in the United States). Using visual representation of the hip joint, participants reported whether they had hip pain on most days and the location of the pain: anterior, groin, lateral, buttocks, or low back. In the Framingham study, participants with hip pain were also examined for hip pain with internal rotation. The authors analysed the agreement between radiographic hip osteoarthritis and hip pain, and for those with hip pain suggestive of hip osteoarthritis they calculated the sensitivity, specificity, positive predictive value, and negative predictive value of radiographs as the diagnostic test. Study answer and limitations In the Framingham study (n=946), only 15.6% of hips in patients with frequent hip pain showed radiographic evidence of hip osteoarthritis, and 20.7% of hips with radiographic hip osteoarthritis were frequently painful. The sensitivity of radiographic hip osteoarthritis for hip pain localised to the groin was 36.7%, specificity 90.5%, positive predictive value 6.0%, and negative predictive value 98.9%. Results did not differ much for hip pain at other locations or for painful internal rotation. In the Osteoarthritis Initiative study (n=4366), only 9.1% of hips in patients with frequent pain showed radiographic hip osteoarthritis, and 23.8% of hips with radiographic hip osteoarthritis were frequently painful. The sensitivity of definite radiographic hip osteoarthritis for hip pain localised to the groin was 16.5%, specificity 94.0%, positive predictive value 7.1%, and negative predictive value 97.6%. Results also did not differ much for hip pain at other locations. What this study adds Hip pain was not present in many hips with radiographic osteoarthritis, and many hips with pain did not show radiographic hip osteoarthritis. Most older participants with a high suspicion for clinical hip osteoarthritis (groin or anterior pain and/or painful internal rotation) did not have radiographic hip osteoarthritis, suggesting that in many cases, hip osteoarthritis might be missed if diagnosticians relied solely on hip radiographs. Funding, competing interests, data sharing See the full paper on thebmj.com for funding. The authors have no competing interests. Additional data are available from bevochan@bu.edu. PMID:26631296

  10. Follow-up chest radiographic findings in patients with MERS-CoV after recovery

    PubMed Central

    Das, Karuna M; Lee, Edward Y; Singh, Rajvir; Enani, Mushira A; Al Dossari, Khalid; Van Gorkom, Klaus; Larsson, Sven G; Langer, Ruth D

    2017-01-01

    Purpose: To evaluate the follow-up chest radiographic findings in patients with Middle East respiratory syndrome coronavirus (MERS-CoV) who were discharged from the hospital following improved clinical symptoms. Materials and Methods: Thirty-six consecutive patients (9 men, 27 women; age range 21–73 years, mean ± SD 42.5 ± 14.5 years) with confirmed MERS-CoV underwent follow-up chest radiographs after recovery from MERS-CoV. The 36 chest radiographs were obtained at 32 to 230 days with a median follow-up of 43 days. The reviewers systemically evaluated the follow-up chest radiographs from 36 patients for lung parenchymal, airway, pleural, hilar and mediastinal abnormalities. Lung parenchyma and airways were assessed for consolidation, ground-glass opacity (GGO), nodular opacity and reticular opacity (i.e., fibrosis). Follow-up chest radiographs were also evaluated for pleural thickening, pleural effusion, pneumothorax and lymphadenopathy. Patients were categorized into two groups: group 1 (no evidence of lung fibrosis) and group 2 (chest radiographic evidence of lung fibrosis) for comparative analysis. Patient demographics, length of ventilations days, number of intensive care unit (ICU) admission days, chest radiographic score, chest radiographic deterioration pattern (Types 1-4) and peak lactate dehydrogenase level were compared between the two groups using the student t-test, Mann-Whitney U test and Fisher's exact test. Results: Follow-up chest radiographs were normal in 23 out of 36 (64%) patients. Among the patients with abnormal chest radiographs (13/36, 36%), the following were found: lung fibrosis in 12 (33%) patients GGO in 2 (5.5%) patients, and pleural thickening in 2 (5.5%) patients. Patients with lung fibrosis had significantly greater number of ICU admission days (19 ± 8.7 days; P value = 0.001), older age (50.6 ± 12.6 years; P value = 0.02), higher chest radiographic scores [10 (0-15.3); P value = 0.04] and higher peak lactate dehydrogenase levels (315-370 U/L; P value = 0.001) when compared to patients without lung fibrosis. Conclusion: Lung fibrosis may develop in a substantial number of patients who have recovered from Middle East respiratory syndrome coronavirus (MERS-CoV). Significantly greater number of ICU admission days, older age, higher chest radiographic scores, chest radiographic deterioration patterns and peak lactate dehydrogenase levels were noted in the patients with lung fibrosis on follow-up chest radiographs after recovery from MERS-CoV. PMID:29089687

  11. Acute Middle East Respiratory Syndrome Coronavirus: Temporal Lung Changes Observed on the Chest Radiographs of 55 Patients.

    PubMed

    Das, Karuna M; Lee, Edward Y; Al Jawder, Suhayla E; Enani, Mushira A; Singh, Rajvir; Skakni, Leila; Al-Nakshabandi, Nizar; AlDossari, Khalid; Larsson, Sven G

    2015-09-01

    The objective of our study was to describe lung changes on serial chest radiographs from patients infected with the acute Middle East respiratory syndrome corona-virus (MERS-CoV) and to compare the chest radiographic findings and final outcomes with those of health care workers (HCWs) infected with the same virus. Chest radiographic scores and comorbidities were also examined as indicators of a fatal outcome to determine their potential prognostic value. Chest radiographs of 33 patients and 22 HCWs infected with MERS-CoV were examined for radiologic features indicative of disease and for evidence of radiographic deterioration and progression. Chest radiographic scores were estimated after dividing each lung into three zones. The scores (1 [mild] to 4 [severe]) for all six zones per chest radiographic examination were summed to provide a cumulative chest radiographic score (range, 0-24). Serial radiographs were also examined to assess for radiographic deterioration and progression from type 1 (mild) to type 4 (severe) disease. Multivariate logistic regression analysis, Kaplan-Meier survival curve analysis, and the Mann-Whitney U test were used to compare data of deceased patients with those of individuals who recovered to identify prognostic radiographic features. Ground-glass opacity was the most common abnormality (66%) followed by consolidation (18%). Overall mortality was 35% (19/55). Mortality was higher in the patient group (55%, 18/33) than in the HCW group (5%, 1/22). The mean chest radiographic score for deceased patients was significantly higher than that for those who recovered (13 ± 2.6 [SD] vs 5.8 ± 5.6, respectively; p = 0.001); in addition, higher rates of pneumothorax (deceased patients vs patients who recovered, 47% vs 0%; p = 0.001), pleural effusion (63% vs 14%; p = 0.001), and type 4 radiographic progression (63% vs 6%; p = 0.001) were seen in the deceased patients compared with those who recovered. Univariate and logistic regression analyses identified the chest radiographic score as an independent predictor of mortality (odds ratio [OR], 1.38; 95% CI, 1.07-1.77; p = 0.01). The number of comorbidities in the patient group (n = 33) was significantly higher than that in the HCW group (n = 22) (mean number of comorbidities, 1.90 ± 1.27 vs 0.17 ± 0.65, respectively; p = 0.001). The Kaplan-Meier analysis revealed a median survival time of 15 days (95% CI, 4-26 days). Ground-glass opacity in a peripheral location was the most common abnormality noted on chest radiographs. A higher chest radiographic score coupled with a high number of medical comorbidities was associated with a poor prognosis and higher mortality in those infected with MERS-CoV. Younger HCWs with few or no comorbidities had a higher survival rate.

  12. The role of modern diagnostic imaging in diagnosing and differentiating kidney diseases in children.

    PubMed

    Maliborski, Artur; Zegadło, Arkadiusz; Placzyńska, Małgorzata; Sopińska, Małgorzata; Lichosik, Marianna; Jobs, Katarzyna

    2018-01-01

    Urinary tract diseases are in the group of the most commonly diagnosed medical conditions in pediatric patients. Many diseases with different etiologies are accompanied by pain, fever, hematuria, or urinary tract dysfunction. Those most common ones in children are urinary tract infections and congenital malformation. They can also represent tumors or changes caused by systemic diseases. Clinical tests and even more often additional imaging studies are required to make a proper diagnosis of urinary tract diseases. Just a few decades ago urography, cystography or voiding cystourethrography were the main methods in diagnostic imaging of the urinary tract. Today's imaging methods supported by digital radiographic and fluoroscopy systems, high sensitivity detectors with quantum detection, advanced algorithms eliminating motion artifacts, modern medical imaging monitors with a resolution of three or even eight megapixels significantly differ from conventional radiographic methods. The methods that are currently usually performed are: computed tomography, magnetic resonance imaging, isotopic methods and ultrasonography using elastography and new solutions in Doppler imaging. Modern techniques are currently focused on reducing radiation exposure with better imaging capabilities. The development of these techniques became an essential diagnostic aid in nephrological and urological practice. The aim of this paper is to present the latest solutions that are currently used in the diagnostic imaging of urinary tract diseases.

  13. Panoramic radiographic predictors of mandibular third molar eruption.

    PubMed

    Niedzielska, Iwona Anna; Drugacz, Jan; Kus, Nina; Kreska, Joanna

    2006-08-01

    Third molar (M3) eruption can be problematic. According to some orthodontic surgeons, the teeth are capable of aggravating the average crowding level in the dental arch. The question is whether it might be possible to give a prognosis for ultimate M3 position in the arch and make an early decision to extract or retain them. The purpose of the study was to determine which measurements made on panoramic tomograms might facilitate prognosis for M3 position in the dental arch over the years. The investigation involved 64 patients who had been enrolled to the study group 10 years earlier, ie, in 1993, when an analysis had been carried out regarding M3 effect on dental arch crowding. At that time panoramic tomograms had been taken, and dental casts made. The procedures were repeated in 2003. The following measurements were taken at baseline (1993) and at the end of the study (2003): (1)/the retromolar space to lower third molar crown width, (2) third molar angulation to the base of the mandible, and (3) third molar to second molar inclination. At some defined values of the Ganss ratio, and M3 inclination to mandibular base and second molar, it is possible to predict potential lower third molar alignment in the dental arch using a panoramic radiograph.

  14. Static-stress analysis of dual-axis confinement vessel

    NASA Astrophysics Data System (ADS)

    Bultman, D. H.

    1992-11-01

    This study evaluates the static-pressure containment capability of a 6-ft-diameter, spherical vessel, made of HSLA-100 steel, to be used for high-explosive (HE) containment. The confinement vessel is designed for use with the Dual-Axis Radiographic Hydrotest Facility (DARHT) being developed at Los Alamos National Laboratory. Two sets of openings in the vessel are covered with x-ray transparent covers to allow radiographic imaging of an explosion as it occurs inside the vessel. The confinement vessel is analyzed as a pressure vessel based on the ASME Boiler and Pressure Vessel Code, Section 8, Division 1, and the Welding Research Council Bulletin, WRC-107. Combined stresses resulting from internal pressure and external loads on nozzles are calculated and compared with the allowable stresses for HSLA-100 steel. Results confirm that the shell and nozzles of the confinement vessel are adequately designed to safely contain the maximum residual pressure of 1675 psi that would result from an HE charge of 24.2 kg detonated in a vacuum. Shell stresses at the shell-to-nozzle interface, produced from external loads on the nozzles, were less than 400 psi. The maximum combined stress resulting from the internal pressure plus external loads was 16,070 psi, which is less than half the allowable stress of 42,375 psi for HSLA-100 steel.

  15. Transitioning to digital radiography.

    PubMed

    Drost, Wm Tod

    2011-04-01

    To describe the different forms of digital radiography (DR), image file formats, supporting equipment and services required for DR, storage of digital images, and teleradiology. Purchasing a DR system is a major investment for a veterinary practice. Types of DR systems include computed radiography, charge coupled devices, and direct or indirect DR. Comparison of workflow for analog and DR is presented. On the surface, switching to DR involves the purchase of DR acquisition hardware. The X-ray machine, table and grids used in analog radiography are the same for DR. Realistically, a considerable infrastructure supports the image acquisition hardware. This infrastructure includes monitors, computer workstations, a robust computer network and internet connection, a plan for storage and back up of images, and service contracts. Advantages of DR compared with analog radiography include improved image quality (when used properly), ease of use (more forgiving to the errors of radiographic technique), speed of making a complete study (important for critically ill patients), fewer repeat radiographs, less time looking for imaging studies, less physical storage space, and the ability to easily send images for consultation. With an understanding of the infrastructure requirements, capabilities and limitations of DR, an informed veterinary practice should be better able to make a sound decision about transitioning to DR. © Veterinary Emergency and Critical Care Society 2011.

  16. Two new methods to increase the contrast of track-etch neutron radiographs

    NASA Technical Reports Server (NTRS)

    Morley, J.

    1971-01-01

    Methods for increasing the (optical density span) of radiographs were evaluated. In one method, fluorescent dye was deposited in the tracks of the radiograph. The radiograph was then examined under ultraviolet light. The second method was a crossed Polaroid filter technique. The radiograph was placed between the filters and then illuminated with a diffuse white-light source. An increase in the optical density span from .10 to .37 was obtained with the dye method. With the Polaroid method, the increase obtained was from .10 to 2.4.

  17. Study of methods of improving the performance of the Langley Research Center Transonic Dynamics Tunnel (TDT)

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A study has been made of possible ways to improve the performance of the Langley Research Center's Transonic Dynamics Tunnel (TDT). The major effort was directed toward obtaining increased dynamic pressure in the Mach number range from 0.8 to 1.2, but methods to increase Mach number capability were also considered. Methods studied for increasing dynamic pressure capability were higher total pressure, auxiliary suction, reducing circuit losses, reduced test medium temperature, smaller test section and higher molecular weight test medium. Increased Mach number methods investigated were nozzle block inserts, variable geometry nozzle, changes in test section wall configuration, and auxiliary suction.

  18. Volterra representation enables modeling of complex synaptic nonlinear dynamics in large-scale simulations.

    PubMed

    Hu, Eric Y; Bouteiller, Jean-Marie C; Song, Dong; Baudry, Michel; Berger, Theodore W

    2015-01-01

    Chemical synapses are comprised of a wide collection of intricate signaling pathways involving complex dynamics. These mechanisms are often reduced to simple spikes or exponential representations in order to enable computer simulations at higher spatial levels of complexity. However, these representations cannot capture important nonlinear dynamics found in synaptic transmission. Here, we propose an input-output (IO) synapse model capable of generating complex nonlinear dynamics while maintaining low computational complexity. This IO synapse model is an extension of a detailed mechanistic glutamatergic synapse model capable of capturing the input-output relationships of the mechanistic model using the Volterra functional power series. We demonstrate that the IO synapse model is able to successfully track the nonlinear dynamics of the synapse up to the third order with high accuracy. We also evaluate the accuracy of the IO synapse model at different input frequencies and compared its performance with that of kinetic models in compartmental neuron models. Our results demonstrate that the IO synapse model is capable of efficiently replicating complex nonlinear dynamics that were represented in the original mechanistic model and provide a method to replicate complex and diverse synaptic transmission within neuron network simulations.

  19. Volterra representation enables modeling of complex synaptic nonlinear dynamics in large-scale simulations

    PubMed Central

    Hu, Eric Y.; Bouteiller, Jean-Marie C.; Song, Dong; Baudry, Michel; Berger, Theodore W.

    2015-01-01

    Chemical synapses are comprised of a wide collection of intricate signaling pathways involving complex dynamics. These mechanisms are often reduced to simple spikes or exponential representations in order to enable computer simulations at higher spatial levels of complexity. However, these representations cannot capture important nonlinear dynamics found in synaptic transmission. Here, we propose an input-output (IO) synapse model capable of generating complex nonlinear dynamics while maintaining low computational complexity. This IO synapse model is an extension of a detailed mechanistic glutamatergic synapse model capable of capturing the input-output relationships of the mechanistic model using the Volterra functional power series. We demonstrate that the IO synapse model is able to successfully track the nonlinear dynamics of the synapse up to the third order with high accuracy. We also evaluate the accuracy of the IO synapse model at different input frequencies and compared its performance with that of kinetic models in compartmental neuron models. Our results demonstrate that the IO synapse model is capable of efficiently replicating complex nonlinear dynamics that were represented in the original mechanistic model and provide a method to replicate complex and diverse synaptic transmission within neuron network simulations. PMID:26441622

  20. Inspection of wood density by spectrophotometry and a diffractive optical element based sensor

    NASA Astrophysics Data System (ADS)

    Palviainen, Jari; Silvennoinen, Raimo

    2001-03-01

    Correlation among gravimetric, spectrophotometric and radiographic data from dried wood samples of Scots pine (Pinus sylvestris L) was observed. A diffractive optical element (DOE) based sensor was applied to investigate density variations as well as optical anisotropy inside year rings of the wood samples. The correlation between bulk density of wood and spectrophotometric data (reflectance and transmittance) was investigated for the wavelength range 200-850 nm and the highest correlation was found at wavelengths from 800 to 850 nm. The correlation at this wavelength was smaller than the correlation between bulk density and radiography data. The DOE sensor was found to be capable of sensing anisotropy of the wood samples inside the year ring.

  1. Clinical imaging of the pancreas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    May, G.; Gardiner, R.

    1987-01-01

    Featuring more than 300 high-quality radiographs and scan images, clinical imaging of the pancreas systematically reviews all appropriate imaging modalities for diagnosing and evaluating a variety of commonly encountered pancreatic disorders. After presenting a succinct overview of pancreatic embryology, anatomy, and physiology, the authors establish the clinical indications-including postoperative patient evaluation-for radiologic examination of the pancreas. The diagnostic capabilities and limitations of currently available imaging techniques for the pancreas are thoroughly assessed, with carefully selected illustrations depicting the types of images and data obtained using these different techniques. The review of acute and chronic pancreatitis considers the clinical features andmore » possible complications of their variant forms and offers guidance in selecting appropriate imaging studies.« less

  2. Attitudes and perceptions of radiographers applying lead (Pb) protection in general radiography: An ethnographic study.

    PubMed

    Hayre, C M; Blackman, S; Carlton, K; Eyden, A

    2018-02-01

    Since the discovery of X-rays by Rontgen in 1895, lead (Pb) has been used to limit ionising radiation for both operators and patients due to its high density and high atomic number (Z = 82). This study explores the attitudes and perceptions of diagnostic radiographers applying Pb protection during general radiographic examinations, an area underexplored within a contemporary radiographic environment(s). This paper presents findings from a wider ethnographic study undertaken in the United Kingdom (UK). The use of participant observation and semi-structured interviews were the methods of choice. Participant observation enabled the overt researcher to uncover whether Pb remained an essential tool for radiographers. Semi-structured interviews later supported or refuted the limited use of Pb protection by radiographers. These methods enabled the construction of original phenomena within the clinical environment. Two themes are discussed. Firstly, radiographers, underpinned by their own values and beliefs towards radiation risk, identify a dichotomy of applying Pb protection. The cessation of Pb may be linked to cultural myths, relying on 'word of mouth' of peers and not on the existing evidence-base. Secondly, radiographers acknowledge that protecting pregnant patients may be primarily a 'personal choice' in clinical environments, which can alter if a patient requests 'are you going to cover me up?' This paper concludes by affirming the complexities surrounding Pb protection in clinical environments. It is proposed that the use of Pb protection in general radiography may become increasingly fragmented in the future if radiographers continue rely on cultural norms. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  3. Preoperative thoracic radiographic findings in dogs presenting for gastric dilatation-volvulus (2000-2010): 101 cases.

    PubMed

    Green, Jaime L; Cimino Brown, Dorothy; Agnello, Kimberly A

    2012-10-01

    To identify the incidence of clinically significant findings on preoperative thoracic radiographs in dogs with gastric dilatation-volvulus (GDV) and to determine if those findings are associated with survival. Retrospective study from 2000 to 2010. Urban university small animal teaching hospital. One hundred and one dogs diagnosed with GDV that had thoracic radiographs obtained preoperatively, and medical records available with the following information available: signalment, time of presentation, respiratory status, plasma lactate, presence of cardiac arrhythmias, reason for thoracic radiographs, radiographic findings, and outcome. None. Findings on preoperative thoracic radiographs included small vena cava (40%), esophageal dilation (39%), microcardia (34%), aspiration pneumonia (14%), cardiomegaly (5%), pulmonary nodule (4%), pulmonary edema (2%), sternal lymphadenopathy (1%), and pulmonary bullae (1%). Eighty-four percent of dogs (85 out of 101) survived to discharge. Dogs without cardiomegaly on presenting thoracic radiographs had a 10.2 greater odds of surviving to discharge. The most common findings on preoperative thoracic radiographs include esophageal dilation, microcardia, and a small vena cava while the incidence of pulmonary nodules was low. A negative association between survival and presence of cardiomegaly on preoperative thoracic radiographs in dogs with GDV supports the need to obtain these images for prognostic information in spite of the emergency surgical nature of the GDV. The main limitations of this study include the possibilities of type I and type II errors, the retrospective nature of the study, and the lack of well-defined criteria for obtaining thoracic radiographs. © Veterinary Emergency and Critical Care Society 2012.

  4. Frequency of radiographic damage and progression in individual joints in children with juvenile idiopathic arthritis.

    PubMed

    Giancane, Gabriella; Pederzoli, Silvia; Norambuena, Ximena; Ioseliani, Maka; Sato, Juliana; Gallo, Maria Chiara; Negro, Giorgia; Pistorio, Angela; Ruperto, Nicolino; Martini, Alberto; Ravelli, Angelo

    2014-01-01

    To evaluate the presence and progression of radiographic joint damage, as assessed with the adapted Sharp/van der Heijde score (SHS), in individual joints in the hand and wrist in patients with juvenile idiopathic arthritis (JIA) and to compare progression of damage among different JIA categories. A total of 372 radiographs of both wrists and hands obtained at first observation and at last followup visit (after 1-10 years) in 186 children with polyarticular-course JIA were evaluated. All radiographs were scored using the adapted SHS by 2 independent readers. Radiographic assessment included evaluation of joint space narrowing (JSN) and erosions on baseline and last followup radiographs and of progression of radiographic changes from baseline to last followup radiographs. Both JSN and erosions occurred in all adapted SHS areas. Overall, radiographic damage and progression were more common in the wrist and less common in metacarpophalangeal (MCP) joints. The hamate and capitate areas appeared particularly vulnerable to cartilage loss. Erosions were identified most frequently in the hamate and capitate bones as well as in the second and third metacarpal bases. Patients with extended oligoarthritis were distinctly less susceptible to JSN in hand joints, whereas patients with polyarthritis showed a greater tendency to developing erosions in hand joints. Radiographic joint damage and progression in our patients with JIA were seen most commonly in the wrist and less commonly in MCP joints. The frequency and localization of structural abnormalities differed markedly across disease categories. Copyright © 2014 by the American College of Rheumatology.

  5. Technologist-Directed Repeat Musculoskeletal and Chest Radiographs: How Often Do They Impact Diagnosis?

    PubMed

    Rosenkrantz, Andrew B; Jacobs, Jill E; Jain, Nidhi; Brusca-Augello, Geraldine; Mechlin, Michael; Parente, Marc; Recht, Michael P

    2017-12-01

    Radiologic technologists may repeat images within a radiographic examination because of perceived suboptimal image quality, excluding these original images from submission to a PACS. This study assesses the appropriateness of technologists' decisions to repeat musculoskeletal and chest radiographs as well as the utility of repeat radiographs in addressing examinations' clinical indication. We included 95 musculoskeletal and 87 chest radiographic examinations in which the technologist repeated one or more images because of perceived image quality issues, rejecting original images from PACS submission. Rejected images were retrieved from the radiograph unit and uploaded for viewing on a dedicated server. Musculoskeletal and chest radiologists reviewed rejected and repeat images in their timed sequence, in addition to the studies' remaining images. Radiologists answered questions regarding the added value of repeat images. The reviewing radiologist agreed with the reason for rejection for 64.2% of musculoskeletal and 60.9% of chest radiographs. For 77.9% and 93.1% of rejected radiographs, the clinical inquiry could have been satisfied without repeating the image. For 75.8% and 64.4%, the repeated images showed improved image quality. Only 28.4% and 3.4% of repeated images were considered to provide additional information that was helpful in addressing the clinical question. Most repeated radiographs (chest more so than musculoskeletal radiographs) did not add significant clinical information or alter diagnosis, although they did increase radiation exposure. The decision to repeat images should be made after viewing the questionable image in context with all images in a study and might best be made by a radiologist rather than the performing technologist.

  6. Utility of plain radiographs in detecting traumatic injuries of the cervical spine in children.

    PubMed

    Nigrovic, Lise E; Rogers, Alexander J; Adelgais, Kathleen M; Olsen, Cody S; Leonard, Jeffrey R; Jaffe, David M; Leonard, Julie C

    2012-05-01

    The objective of this study was to estimate the sensitivity of plain radiographs in identifying bony or ligamentous cervical spine injury in children. We identified a retrospective cohort of children younger than 16 years with blunt trauma-related bony or ligamentous cervical spine injury evaluated between 2000 and 2004 at 1 of 17 hospitals participating in the Pediatric Emergency Care Applied Research Network. We excluded children who had a single or undocumented number of radiographic views or one of the following injuries types: isolated spinal cord injury, spinal cord injury without radiographic abnormalities, or atlantoaxial rotary subluxation. Using consensus methods, study investigators reviewed the radiology reports and assigned a classification (definite, possible, or no cervical spine injury) as well as film adequacy. A pediatric neurosurgeon, blinded to the classification of the radiology reports, reviewed complete case histories and assigned final cervical spine injury type. We identified 206 children who met inclusion criteria, of which 127 had definite and 41 had possible cervical spine injury identified by plain radiograph. Of the 186 children with adequate cervical spine radiographs, 168 had definite or possible cervical spine injury identified by plain radiograph for a sensitivity of 90% (95% confidence interval, 85%-94%). Cervical spine radiographs did not identify the following cervical spine injuries: fracture (15 children) and ligamentous injury alone (3 children). Nine children with normal cervical spine radiographs presented with 1 or more of the following: endotracheal intubation (4 children), altered mental status (5 children), or focal neurologic findings (5 children). Plain radiographs had a high sensitivity for cervical spine injury in our pediatric cohort.

  7. A systematic review of the association between radiographic and clinical osteoarthritis of hip and knee.

    PubMed

    Kinds, M B; Welsing, P M J; Vignon, E P; Bijlsma, J W J; Viergever, M A; Marijnissen, A C A; Lafeber, F P J G

    2011-07-01

    There is ongoing debate on whether an association between radiographic and clinical osteoarthritis (OA) exists. We hypothesized that the inconsistency in the detection of an association might be caused by different definitions of OA, by different radiographic protocols, and by scoring methods for radiographic damage and symptoms. The goal of this study was to evaluate which methodological criteria are important to detect an association between radiographic and clinical OA of hip and knee. A literature search was performed with the keywords 'OA', 'hip', 'knee', 'radiographic', and 'clinical' and results were screened for relevant studies. Quality criteria for study characteristics and methodology were developed. Studies were classified according to these criteria and the presence of an association between radiographic and clinical OA was scored. The importance of methodological quality and patient characteristics on the presence of an association was evaluated. The literature search resulted in 39 studies describing an association between radiographic and clinical OA. The frequency of an association between radiographic and clinical OA outcome measures diminished when less quality criteria were fulfilled. Specifically the criterion for standardized outcome measures appeared important in the detection of an association. The association was not influenced by patient characteristics. Only four studies were identified that fulfilled all quality criteria and in these studies an association was found for the knee joint and an inconsistent association was found for the hip joint. Methodological quality criteria are of importance to reveal an association between radiographic and clinical OA. Copyright © 2011 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  8. Film and digital periapical radiographs for the measurement of apical root shortening.

    PubMed

    El-Angbawi, Ahmed M F; McIntyre, Grant T; Bearn, David R; Thomson, Donald J

    2012-12-01

    The aim of this study was to compare the accuracy and agreement of scanned film and digital periapical radiographs for the measurement of apical root shortening. Twenty-four film and digital [phosphor plate sensor (PPS)] periapical radiographs were taken using the long-cone paralleling technique for six extracted teeth before and after 1mm of apical root trimming. All teeth were mounted using a typodont and the radiographs were recorded using a film holder and polysiloxane occlusal index for each tooth to ensure standardization during the different radiographic exposures. The film radiographs were scanned and the tooth length measurements for the scanned film and digital (PPS) images were calculated using Image-J-Link 1.4 software (http://rebweb.nih.gov/ij/index.html) for the two groups. The accuracy and agreement among the tooth length measurements from each group and the true tooth length measurements were calculated using intra-class correlation (ICC) tests and Bland and Altman plots. A high level of agreement was found between the true tooth length measurements and the scanned film measurements (ICC=0.979, limit of agreement 0.579 to -0.565) and the digital (PPS) radiograph measurements (ICC= 0.979, limit of agreement 0.596 to -0.763). Moreover, a high level of agreement was found between the scanned film and digital (PPS) radiographs for the measurement of tooth length ICC=0.991, limit of agreement 0.411-0.231. Film and digital (PPS) periapical radiographs are accurate methods for measuring apical root shortening with a high level of agreement. Key words:Root shortening, measurement, periapical radiographs, film, digital.

  9. Solid radiographic fusion with a nonconstrained device 5 years after cervical arthroplasty.

    PubMed

    Heary, Robert F; Goldstein, Ira M; Getto, Katarzyna M; Agarwal, Nitin

    2014-12-01

    Cervical disc arthroplasty (CDA) has been gaining popularity as a surgical alternative to anterior cervical discectomy and fusion. Spontaneous fusion following a CDA is uncommon. A few anecdotal reports of heterotrophic ossification around the implant sites have been noted for the BRYAN, ProDisc-C, Mobi-C, PRESTIGE, and PCM devices. All CDA fusions reported to date have been in devices that are semiconstrained. The authors reported the case of a 56-year-old man who presented with left C-7 radiculopathy and neck pain for 10 weeks after an assault injury. There was evidence of disc herniation at the C6-7 level. He was otherwise healthy with functional scores on the visual analog scale (VAS, 4.2); neck disability index (NDI, 16); and the 36-item short form health survey (SF-36; physical component summary [PSC] score 43 and mental component summary [MCS] score 47). The patient underwent total disc replacement in which the DISCOVER Artificial Cervical Disc (DePuy Spine, Inc.) was used. The patient was seen at regular follow-up visits up to 60 months. At his 60-month follow-up visit, he had complete radiographic fusion at the C6-7 level with bridging trabecular bone and no motion at the index site on dynamic imaging. He was pain free, with a VAS score of 0, NDI score of 0, and SF-36 PCS and MCS scores of 61 and 55, respectively. Conclusions This is the first case report that identifies the phenomenon of fusion around a nonconstrained cervical prosthesis. Despite this unwanted radiographic outcome, the patient's clinical outcome was excellent.

  10. Continuing professional development (CPD) in radiography: A collaborative European meta-ethnography literature review.

    PubMed

    Wareing, A; Buissink, C; Harper, D; Gellert Olesen, M; Soto, M; Braico, S; Van Laer, P; Gremion, I; Rainford, L

    2017-09-01

    The aim of the study was to complete a collaborative review of Radiography continuing professional development (CPD) research material to support the production of European Federation of Radiographer Societies (EFRS) CPD recommendations. A meta-ethnography approach to literature review was applied focussing upon commonalities rather than discrepancies between research outcomes. This facilitated exploration of context across the geographical region of Europe with national variations in CPD governance. The seven phases of the meta-ethnographic approach were followed by two independent experienced researchers. A third researcher mediated the findings which were then explored collaboratively with the EFRS CPD working group for concordance. Phase seven of the meta-ethnography involved interpreting an expression of the synthesis from the previous stages. Six main corroborating themes emerged in this process and following mediation were expressed as themes; knowledge, skills & competency, needs/gap analysis, multi-layered/multi-modal, barriers and drivers; regulation vs autonomy; fostering collaboration - harnessing technology. The primary feature of CPD activity should be the resulting impact - to patients, the service, the profession and the individual; with all stakeholders working in partnership. CPD activity must be flexible/multi-modal to support the changing growth/dynamic workforce. All stakeholders should utilise communication and technology resources and make efforts to improve collaboration between the management, regulators and educators to support Radiographers to develop meaningful CPD. Health services across Europe are under increasing stress and a principal factor going forwards will be managing increasing demands on healthcare staff whilst supporting enhancement of the knowledge, skills and competency base. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  11. Radiographic prevalence of CAM-type femoroacetabular impingement after open reduction and internal fixation of femoral neck fractures.

    PubMed

    Mathew, G; Kowalczuk, M; Hetaimish, B; Bedi, A; Philippon, M J; Bhandari, M; Simunovic, N; Crouch, S; Ayeni, O R

    2014-04-01

    The purpose of this study was to estimate the radiographic prevalence of CAM-type femoroacetabular impingement (FAI) in elderly patients (≥ 50 years) who have undergone internal fixation for femoral neck fracture. A total of 187 frog-leg lateral radiographs of elderly patients who underwent internal fixation for a femoral neck fracture were reviewed by two independent reviewers. The alpha angle, beta angle, and femoral head-neck offset ratio were calculated. The presence of two abnormal radiographic parameters was deemed to be diagnostic of radiographic CAM-type impingement. Radiographic CAM-type FAI was identified in 157 out of 187 (84 %) patients who underwent internal fixation for fractures of the femoral neck. Moderate-to-good inter-observer reliability was achieved in the measurement of radiographic parameters. With reference to fracture subtypes and prevalence of radiographic features of CAM-type morphology, 97 (72 %) out of 134 patients were positive for CAM in Garden subtypes I and II, whereas 49 (85.9 %) out of 57 patients had radiographic CAM in Garden III and IV subtypes. There was a high prevalence of CAM-type FAI in patients that underwent surgical fixation of femoral neck fractures. This is significantly higher than the reported prevalence in non-fracture patient populations. The high prevalence of CAM morphology could be related to several factors, including age, fracture morphology, quality of reduction, type of fixation, and fracture healing.

  12. [Comparative evaluation of six different body regions of the dog using analog and digital radiography].

    PubMed

    Meyer-Lindenberg, Andrea; Ebermaier, Christine; Wolvekamp, Pim; Tellhelm, Bernd; Meutstege, Freek J; Lang, Johann; Hartung, Klaus; Fehr, Michael; Nolte, Ingo

    2008-01-01

    In this study the quality of digital and analog radiography in dogs was compared. For this purpose, three conventional radiographs (varying in exposure) and three digital radiographs (varying in MUSI-contrast [MUSI = MUlti Scale Image Contrast], the main post-processing parameter) of six different body regions of the dog were evaluated (thorax, abdomen, skull, femur, hip joints, elbow). The quality of the radiographs was evaluated by eight veterinary specialists familiar with radiographic images using a questionnaire based on details of each body region significant in obtaining a radiographic diagnosis. In the first part of the study the overall quality of the radiographs was evaluated. Within one region, 89.5% (43/48) chose a digital radiograph as the best image. Divided into analog and digital groups, the digital image with the highest MUSI-contrast was most often considered the best, while the analog image considered the best varied between the one with the medium and the one with the longest exposure time. In the second part of the study, each image was rated for the visibility of specific, diagnostically important details. After summarisation of the scores for each criterion, divided into analog and digital imaging, the digital images were rated considerably superior to conventional images. The results of image comparison revealed that digital radiographs showed better image detail than radiographs taken with the analog technique in all six areas of the body.

  13. How Reliable is the Acetabular Cup Position Assessment from Routine Radiographs?

    PubMed Central

    Carvajal Alba, Jaime A.; Vincent, Heather K.; Sodhi, Jagdeep S.; Latta, Loren L.; Parvataneni, Hari K.

    2017-01-01

    Abstract Background: Cup position is crucial for optimal outcomes in total hip arthroplasty. Radiographic assessment of component position is routinely performed in the early postoperative period. Aims: The aims of this study were to determine in a controlled environment if routine radiographic methods accurately and reliably assess the acetabular cup position and to assess if there is a statistical difference related to the rater’s level of training. Methods: A pelvic model was mounted in a spatial frame. An acetabular cup was fixed in different degrees of version and inclination. Standardized radiographs were obtained. Ten observers including five fellowship-trained orthopaedic surgeons and five orthopaedic residents performed a blind assessment of cup position. Inclination was assessed from anteroposterior radiographs of the pelvis and version from cross-table lateral radiographs of the hip. Results: The radiographic methods used showed to be imprecise specially when the cup was positioned at the extremes of version and inclination. An excellent inter-observer reliability (Intra-class coefficient > 0,9) was evidenced. There were no differences related to the level of training of the raters. Conclusions: These widely used radiographic methods should be interpreted cautiously and computed tomography should be utilized in cases when further intervention is contemplated. PMID:28852355

  14. A follow-up study of neurologic and radiographic findings in working German Shepherd Dogs with and without degenerative lumbosacral stenosis.

    PubMed

    Steffen, Frank; Hunold, Katharina; Scharf, Gernot; Roos, Malgorzata; Flückiger, Mark

    2007-11-15

    To identify radiographic abnormalities associated with degenerative lumbosacral stenosis (DLSS) in German Shepherd Dogs (GSDs) and determine whether specific radiographic abnormalities could be used to identify dogs at risk of developing DLSS. Cohort study. 33 GSDs working as police dogs. Results of physical, neurologic, and orthopedic examinations were used to identify dogs with DLSS. Survey radiography of the lumbosacral junction was performed, and radiographs were compared with radiographs obtained 3 years earlier. DLSS was diagnosed in 15 of the 33 (45%) dogs. Thirteen of the 15 dogs with DLSS and 14 of the 18 dogs without DLSS had radiographic abnormalities of the lumbosacral junction. Twenty-two (67%) dogs were able to perform unrestricted duties, including 3 dogs with suspected DLSS. Six (18%) dogs had been excluded from active duty during the period of surveillance because of DLSS. Significant progression in specific clinical and radiographic signs was detected, but multiple logistic regression analysis did not identify any radiographic signs that could be used to predict the development of DLSS. Results suggested that survey radiography cannot be used to predict development of DLSS in working GSDs.

  15. Design and dynamic simulation of a fixed pitch 56 kW wind turbine drive train with a continuously variable transmission

    NASA Technical Reports Server (NTRS)

    Gallo, C.; Kasuba, R.; Pintz, A.; Spring, J.

    1986-01-01

    The dynamic analysis of a horizontal axis fixed pitch wind turbine generator (WTG) rated at 56 kW is discussed. A mechanical Continuously Variable Transmission (CVT) was incorporated in the drive train to provide variable speed operation capability. One goal of the dynamic analysis was to determine if variable speed operation, by means of a mechanical CVT, is capable of capturing the transient power in the WTG/wind environment. Another goal was to determine the extent of power regulation possible with CVT operation.

  16. Factors affecting radiographers' organizational commitment.

    PubMed

    Akroyd, Duane; Jackowski, Melissa B; Legg, Jeffrey S

    2007-01-01

    A variety of factors influence employees' attitudes toward their workplace and commitment to the organization that employs them. However, these factors have not been well documented among radiologic technologists. To determine the predictive ability of selected organizational, leadership, work-role and demographic variables on organizational commitment for a national sample of radiographers. Three thousand radiographers registered by the American Registry of Radiologic Technologists working full time in clinical settings were surveyed by mail regarding their commitment to their employers, leadership within the organization that employs them, employer support and demographic information. Overall, radiographers were found to have only a moderate level of commitment to their employers. Among the factors that significantly affected commitment were the radiographer's educational level, perceived level of organizational support, role clarity and organizational leadership. The results of this study could provide managers and supervisors with insights on how to empower and challenge radiographers and offer opportunities that will enhance radiographers' commitment to the organization, thus reducing costly turnover and improving employee performance.

  17. A retrospective study of a modified 1-minute formocresol pulpotomy technique part 1: clinical and radiographic findings.

    PubMed

    Kurji, Zahra A; Sigal, Michael J; Andrews, Paul; Titley, Keith

    2011-01-01

    The purpose of this study was to assess the clinical and radiographic outcomes of a 1-minute application of full-strength Buckley's formocresol with concurrent hemostasis using the medicated cotton pledget in human primary teeth. Using a retrospective chart review, clinical and radiographic data were available for 557 primary molars in 320 patients. Descriptive statistics and survival analysis were used to assess outcomes. Overall clinical success, radiographic success, and cumulative 5-year survival rates were approximately 99%, 90%, and 87%, respectively. Internal root resorption (∼5%) and pulp canal obliteration (∼2%) were the most frequently observed radiographic failures. Thirty-nine teeth were extracted due to clinical and or radiographic failure. Mandibular molars were 6 times more prone to radiographic failure than maxillary molars. Success rates for the modified technique are comparable to techniques that use the 5-minute diluted or full-strength solutions reported in the literature. This 1-minute full-strength formocresol technique is an acceptable alternative to published traditional techniques.

  18. Midcarpal instability: a diagnostic role for dynamic ultrasound?

    PubMed

    Toms, A; Chojnowski, A; Cahir, J

    2009-06-01

    The aim of this study was to describe the technique of dynamic ultrasound (US) examination of the triquetral clunk, and to illustrate the range of findings in four patients with midcarpal instability (MCI). Four patients were identified (3 men, 1 woman). The case notes, plain radiographs, MRI and dynamic US for each patient were reviewed. Digital video files recording the dynamic US of the triquetral clunks were analysed for the following features of abnormal triquetral mobility: direction and speed of triquetral snap, amount of anteroposterior translocation, and flexion or extension during the snap. Five different triquetral clunks were recorded in 4 patients. In four out of five cases the clunk occurred during ulnar translocation of the wrist, and in one during radial translocation. Anteroposterior translocation was anterior (3.4 - 4.7 mm) in three of the clunks and posterior (1 - 10 mm) in two. The degree of flexion or extension varied between 1 and 16 degrees . The snapping phase of the clunk lasted between 0.17 and 0.25 seconds. Dynamic US can be used to confirm the diagnosis of midcarpal instability by identifying a triquetral catch-up clunk. Quantification of carpal mobility with US may lead to further insights into the mechanics of MCI.

  19. 21 CFR 892.1960 - Radiographic intensifying screen.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... (a) Identification. A radiographic intensifying screen is a device that is a thin radiolucent sheet... for medical purposes to expose radiographic film. (b) Classification. Class I (general controls). The...

  20. Impact of Organizational Inertia and Dynamic Capabilities on Educational Performance of the Charitable Societies and Its Impact on Mathematical Performance of Elementary At-Risk Students

    ERIC Educational Resources Information Center

    Amiripour, Parvaneh; Dossey, John A.; Shahvarani, Ahmad

    2017-01-01

    This study is an adjunct to a research effort focused on a mathematical curricular innovation in four non-governmental schools in Tehran, Iran. This study queried balanced, random sample of 100 educational personnel from the schools concerning dynamic capabilities associated with change (sensing opportunities, seizing opportunities, and…

  1. Training Delivery Methods as Source of Dynamic Capabilities: The Case of Sports' Organisations

    ERIC Educational Resources Information Center

    Arraya, Marco António Mexia; Porfírio, Jose António

    2017-01-01

    Purpose: Training as an important source of dynamic capabilities (DC) is important to the performance of sports' organisations (SO) both to athletes and to non-athletic staff. There are a variety of training delivery methods (TDMs). The purpose of this study is to determine from a set of six TDMs which one is considered to be the most suitable to…

  2. Efficient Computation Of Manipulator Inertia Matrix

    NASA Technical Reports Server (NTRS)

    Fijany, Amir; Bejczy, Antal K.

    1991-01-01

    Improved method for computation of manipulator inertia matrix developed, based on concept of spatial inertia of composite rigid body. Required for implementation of advanced dynamic-control schemes as well as dynamic simulation of manipulator motion. Motivated by increasing demand for fast algorithms to provide real-time control and simulation capability and, particularly, need for faster-than-real-time simulation capability, required in many anticipated space teleoperation applications.

  3. Development of a model protection and dynamic response monitoring system for the national transonic facility

    NASA Technical Reports Server (NTRS)

    Young, Clarence P., Jr.; Balakrishna, S.; Kilgore, W. Allen

    1995-01-01

    A state-of-the-art, computerized mode protection and dynamic response monitoring system has been developed for the NASA Langley Research Center National Transonic Facility (NTF). This report describes the development of the model protection and shutdown system (MPSS). A technical description of the system is given along with discussions on operation and capabilities of the system. Applications of the system to vibration problems are presented to demonstrate the system capabilities, typical applications, versatility, and investment research return derived from the system to date. The system was custom designed for the NTF but can be used at other facilities or for other dynamic measurement/diagnostic applications. Potential commercial uses of the system are described. System capability has been demonstrated for forced response testing and for characterizing and quantifying bias errors for onboard inertial model attitude measurement devices. The system is installed in the NTF control room and has been used successfully for monitoring, recording and analyzing the dynamic response of several model systems tested in the NTF.

  4. Computational Fluid Dynamics Technology for Hypersonic Applications

    NASA Technical Reports Server (NTRS)

    Gnoffo, Peter A.

    2003-01-01

    Several current challenges in computational fluid dynamics and aerothermodynamics for hypersonic vehicle applications are discussed. Example simulations are presented from code validation and code benchmarking efforts to illustrate capabilities and limitations. Opportunities to advance the state-of-art in algorithms, grid generation and adaptation, and code validation are identified. Highlights of diverse efforts to address these challenges are then discussed. One such effort to re-engineer and synthesize the existing analysis capability in LAURA, VULCAN, and FUN3D will provide context for these discussions. The critical (and evolving) role of agile software engineering practice in the capability enhancement process is also noted.

  5. Measuring x-ray spectra of flash radiographic sources [PowerPoint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gehring, Amanda Elizabeth; Espy, Michelle A.; Haines, Todd Joseph

    2015-11-02

    The x-ray spectra of flash radiographic sources are difficult to measure. The sources measured were Radiographic Integrated Test Stand-6 (370 rad at 1 m; 50 ns pulse) and Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) (550 rad at 1 m; 50 ns pulse). Features of the Compton spectrometer are described, and spectra are shown. Additional slides present data on instrumental calibration.

  6. Weight bearing cone beam CT scan versus gravity stress radiography for analysis of supination external rotation injuries of the ankle.

    PubMed

    Marzo, John M; Kluczynski, Melissa A; Clyde, Corey; Anders, Mark J; Mutty, Christopher E; Ritter, Christopher A

    2017-12-01

    For AO 44-B2 ankle fractures of uncertain stability, the current diagnostic standard is to obtain a gravity stress radiograph, but some have advocated for the use of weight-bearing radiographs. The primary aim was to compare measures of medial clear space (MCS) on weight-bearing cone beam computed tomography (CBCT) scans versus gravity stress radiographs for determining the state of stability of ankle fractures classified as AO SER 44-B2 or Weber B. The secondary aim was to evaluate the details offered by CBCT scans with respect to other findings that may be relevant to patient care. Nine patients were enrolled in this cross-sectional study between April 2016 and February 2017 if they had an AO SER 44-B2 fracture of uncertain stability, had a gravity stress radiograph, and were able to undergo CT scan within seven days. The width of the MCS was measured at the level of the talar dome on all radiographs and at the mid coronal slice on CT. Wilcoxon signed-ranks tests were used to compare MCS between initial radiographs, gravity stress radiographs and weight-bearing CBCT scans. MCS on weight-bearing CBCT scan (1.41±0.41 mm) was significantly less than standard radiographs (3.28±1.63 mm, P=0.004) and gravity stress radiographs (5.82±1.93 mm, P=0.02). There was no statistically significant difference in MCS measured on standard radiographs versus gravity stress radiographs (P=0.11). Detailed review of the multiplanar CT images revealed less than perfect anatomical reduction of the fractures, with residual fibular shortening, posterior displacement, and fracture fragments in the incisura as typical findings. Similar to weight-bearing radiographs, weight-bearing CBCT scan can predict stability of AO 44-B2 ankle fractures by showing restoration of the MCS, and might be used to indicate patients for non-operative treatment. None of the fractures imaged in this study were perfectly reduced however, and further clinical research is necessary to determine if any of the detailed weight-bearing CBCT findings are related to patient outcomes.

  7. Flight experiment of thermal energy storage

    NASA Technical Reports Server (NTRS)

    Namkoong, David

    1989-01-01

    Thermal energy storage (TES) enables a solar dynamic system to deliver constant electric power through periods of sun and shade. Brayton and Stirling power systems under current considerations for missions in the near future require working fluid temperatures in the 1100 to 1300+ K range. TES materials that meet these requirements fall into the fluoride family of salts. These salts store energy as a heat of fusion, thereby transferring heat to the fluid at constant temperature during shade. The principal feature of fluorides that must be taken into account is the change in volume that occurs with melting and freezing. Salts shrink as they solidify, a change reaching 30 percent for some salts. The location of voids that form as result of the shrinkage is critical when the solar dynamic system reemerges into the sun. Hot spots can develop in the TES container or the container can become distorted if the melting salt cannot expand elsewhere. Analysis of the transient, two-phase phenomenon is being incorporated into a three-dimensional computer code. The code is capable of analysis under microgravity as well as 1 g. The objective of the flight program is to verify the predictions of the code, particularly of the void location and its effect on containment temperature. The four experimental packages comprising the program will be the first tests of melting and freezing conducted under microgravity. Each test package will be installed in a Getaway Special container to be carried by the shuttle. The package will be self-contained and independent of shuttle operations other than the initial opening of the container lid and the final closing of the lid. Upon the return of the test package from flight, the TES container will be radiographed and finally partitioned to examine the exact location and shape of the void. Visual inspection of the void and the temperature data during flight will constitute the bases for code verification.

  8. Radiographic findings of femoroacetabular impingement in National Football League Combine athletes undergoing radiographs for previous hip or groin pain.

    PubMed

    Nepple, Jeffrey J; Brophy, Robert H; Matava, Matthew J; Wright, Rick W; Clohisy, John C

    2012-10-01

    The purpose of this study was to investigate the prevalence of radiographic findings of femoroacetabular impingement (FAI) in elite football players with a history of hip pain or groin injury who underwent radiographs. We performed a retrospective review of athletes undergoing hip radiography at the National Football League Combine from 2007 to 2009. Radiographs were obtained in athletes with a history of hip pain or injury. Anteroposterior pelvis and frog-lateral radiographs were obtained in 123 hips (107 players) that met our inclusion criteria. Radiographic indicators of cam-type FAI (alpha angle, head-neck offset ratio) and pincer-type FAI (acetabular retroversion, center-edge angle, acetabular inclination) were recorded. Findings were correlated with clinical factors (previous groin/hip pain, position, race, and body mass index). The most common previous injuries included groin strain (n = 57) and sports hernia/abdominal strain (n = 21). Markers of cam- and/or pincer-type FAI were present in 94.3% of hips (116 of 123). Radiographic evidence of combined cam- and pincer-type FAI was the most common (61.8%, 76 hips), whereas isolated cam-type FAI (9.8%, 12 hips) and pincer-type FAI (22.8%, 28 hips) were less common. The most common deformities included acetabular retroversion (71.5%) and an abnormal alpha angle (61.8%). A body mass index greater than 35 was associated with the presence of global overcoverage (46.2% v 17.3%, P = .025). Radiographic indicators of FAI are very common among athletes evaluated at the National Football League Scouting Combine subjected to radiographic examination for the clinical suspicion of hip disease. Elite football athletes with significant or recurrent pain about the hip should be evaluated clinically and radiographically for FAI, because pain from FAI may be falsely attributed to or may be present in addition to other disorders. Level IV, therapeutic case series. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  9. Radiographic bone loss in a Scottish non-smoking Type 1 Diabetes mellitus population; a Bitewing Radiographic Study.

    PubMed

    Plessas, Anastasios; Robertson, Douglas P; Hodge, Penny J

    2018-05-15

    The dental complications of uncontrolled diabetes include reduced salivary flow rate, candidiasis and periodontal manifestations. A recent meta-analysis concluded that diabetes patients have a significantly higher severity, but not extent, of destructive periodontal disease than non-diabetes people. The authors reported that most type-1 diabetes studies using dental radiographic data have not controlled for confounding factors such as smoking. The aim of this cross-sectional study was to compare radiographic alveolar bone loss between type 1 diabetes (T1DM) and non-diabetes (NDM) participants in a Scottish non-smoking population. Digital bitewing radiographs for 174 Scottish adult never or ex-smoker (> 5 years) participants (108 T1DM, 66 NDS), recruited from outpatient clinics throughout Greater Glasgow and Clyde, were included in the analysis. A single blinded, trained and calibrated examiner recorded the radiographic bone loss seen on bitewing radiographs using the digital screen caliper. The bone loss was measured as the distance between the cemento-enamel junction (CEJ) and the deepest radiographic alveolar bone margin interproximally of each tooth. T1DM participants had more radiographic alveolar bone loss throughout the all teeth measured (median:1.27 mm vs 1.06 mm, P < 0.001) and more than a two fold increase in the risk of having sites with ≥2 mm periodontal destruction (OR = 2.297, 95%CI 1.058-4.986, P = 0.036) compared with non-diabetes subjects. Patients suffering from type 1 diabetes are at higher risk of periodontitis even when controlling for multiple possible confounding factors and this difference can be detected on routine dental radiographs at an early stage. These data confirm radiographically the previously reported association between T1DM and periodontal bone loss. This article is protected by copyright. All rights reserved. © 2018 American Academy of Periodontology.

  10. Variability amongst radiographers in the categorization of clinical acceptability for digital trauma radiography

    NASA Astrophysics Data System (ADS)

    Decoster, Robin; Toomey, Rachel; Smits, Dirk; Mol, Harrie; Verhelle, Filip; Butler, Marie-Louise

    2016-03-01

    Introduction: Radiographers evaluate anatomical structures to judge clinical acceptability of a radiograph. Whether a radiograph is deemed acceptable for diagnosis or not depends on the individual decision of the radiographer. Individual decisions cause variation in the accepted image quality. To minimise these variations definitions of acceptability, such as in RadLex, were developed. On which criteria radiographers attribute a RadLex categories to radiographs is unknown. Insight into these criteria helps to further optimise definitions and reduce variability in acceptance between radiographers. Therefore, this work aims the evaluation of the correlation between the RadLex classification and the evaluation of anatomical structures, using a Visual Grading Analysis (VGA) Methods: Four radiographers evaluated the visibility of five anatomical structures of 25 lateral cervical spine radiographs on a secondary class display with a VGA. They judged clinical acceptability of each radiograph using RadLex. Relations between VGAS and RadLex category were analysed with Kendall's Tau correlation and Nagelkerke pseudo-R². Results: The overall VGA score (VGAS) and the RadLex score correlate (rτ= 0.62, p<0.01, R2=0.72) strongly. The observers' evaluation of contrast between bone, air (trachea) and soft tissue has low value in predicting (rτ=0.55, p<0.01, R2=0.03) the RadLex score. The reproduction of spinous processes (rτ=0.67, p<0.01, R2=0.31) and the evaluation of the exposure (rτ=0.65, p<0.01, R2=0.56) have a strong correlation with high predictive value for the RadLex score. Conclusion: RadLex scores and VGAS correlate positively, strongly and significantly. The predictive value of bony structures may support the use of these in the judgement of clinical acceptability. Considerable inter-observer variations in the VGAS within a certain RadLex category, suggest that observers use of observer specific cut-off values.

  11. Inadequate pelvic radiographs: implications of not getting it right the first time.

    PubMed

    Parker, S; Nagra, N S; Kulkarni, K; Pegrum, J; Barry, S; Hughes, R; Ghani, Y

    2017-09-01

    Introduction Pelvic radiography is a frequent investigation. European guidelines aim to ensure appropriate use and adequate quality. When initial images are inadequate, repeat radiographs are often required, which may have significant patient safety and economic implications. Objectives The study aimed to assess the adequacy of pelvic imaging across three orthopaedic centres, to identify causes for inadequate imaging and to establish the cost of inadequate imaging from financial and patient safety perspectives. Methods Pelvic radiographs were identified on Picture Archiving and Communication System software at three UK hospitals. Radiographs were assessed against European guidelines and indications for repeat imaging were analysed. Results A total of 1,531 sequential pelvic radiographs were reviewed. The mean age of patients was 60 years (range 5 months to 101 years). Of this total, 51.9% of images were suboptimal, with no significant difference across the three hospitals (P > 0.05). Hospital 3 repeated radiographs in 6.3% of cases, compare with 18.1% and 19.7% at hospitals 1 and 2, respectively (P > 0.05). Hospital 3 identified pathology missed on the initial radiograph in 1% of cases, compared with 5.4% and 5.5% at hospitals 1 and 2, respectively (P > 0.05). Out-of-hours imaging is associated with a higher rate of suboptimal quality (69.1%) compared with normal working hours (51.3%; P = 0.006). Adequacy rates vary with age (χ 2 = 43.62, P < 0.001). Risk of having a suboptimal radiograph increases above the age of 60-years (χ 2 = 4.45, P < 0.05). The annual cost of repeat radiographs was £56,200 per hospital. Discussion and conclusion High rates of pelvic radiograph inadequacy can lead to missed pathology and the requirement for repeat imaging, which has significant patient safety and financial implications. Risk factors for inadequate radiographs include older patients and those having out-of-hours imaging.

  12. Comparison of radiographic and clinical diagnosis of approximal and occlusal dental caries in a young adult population.

    PubMed

    Hopcraft, Matthew S; Morgan, Michael V

    2005-06-01

    The aims of the study were: (1) to determine if bitewing radiographs provided additional diagnostic yield for occlusal and approximal dental caries in adults aged between 17 and 30 years of age when compared with a clinical examination only, (2) how this translated into the measurement of dental caries experience, and (3) to determine the influence of water fluoridation on the diagnosis of dental caries in occlusal and approximal surfaces by clinical examination alone and by radiographic examination. Between November 2002 and March 2003 a total of 879 subjects aged 17-30 years had a clinical examination using visual and tactile criteria. Subsequent to this examination, bitewing radiographs were taken and viewed separately and blind. Approximal and occlusal surfaces of molars and premolars were examined on the radiographs. Between 22.9-32.9% of approximal caries and 75.9-82.9% of occlusal caries was detected by clinical examination, while 93.1-97.1% of approximal caries and 33.1-42.6% of occlusal caries was detected by radiographic examination. In addition, while only 0.97% of clinically sound approximal surfaces and 0.83% of clinically sound occlusal surfaces were diagnosed with dentine caries on the radiographs, 67.1-77.1% of approximal caries was detected by radiographs alone, an additional diagnostic yield of 204-336%. The DS score increased 45-46% and the DMFS score increased 6-11% from the clinical examination with the addition of the radiographic information (P<0.001). The prevalence of approximal and occlusal caries was underestimated when clinical means only were employed. There was a significant increase in DS and DMFS scores from the clinical examination only when radiographic information was added across all age groups (P<0.001). This study confirms the value of bitewing radiographs in caries diagnosis.

  13. Weightbearing vs Gravity Stress Radiographs for Stability Evaluation of Supination-External Rotation Fractures of the Ankle.

    PubMed

    Seidel, Angela; Krause, Fabian; Weber, Martin

    2017-07-01

    Isolated lateral malleolar fractures may result from a supination-external rotation (SER) injury of the ankle. Stable fractures maintain tibiotalar congruence due to competent medial restraints and can be treated nonoperatively with excellent functional results and long-term prognosis. Stability might be assessed with either stress radiographs or weightbearing radiographs. A consecutive series of patients with closed SER fractures (presumed AO 44-B1) were prospectively enrolled from 2008 to 2015. Patients with clearly unstable fractures (medial clear space more than 7 mm) on the initial nonweightbearing radiograph were excluded and operated on. All other patients were examined with a gravity stress and a weightbearing anteroposterior radiograph. Borderline instability of the fracture was assumed when the medial clear space was 4 to 7 mm. Those were treated nonoperatively. Of 104 patients with isolated lateral malleolar fractures of the SER type, 14 patients were treated operatively because of clear instability (displacement) on the initial radiographs. Of the nonoperative patients, 44 patients demonstrated borderline instability on the gravity stress but stability on the weightbearing radiograph ("gravity borderline"); the remaining 46 were stable in both tests ("gravity stable"). At an average follow-up of 23 months, no significant differences were seen in the American Orthopaedic Foot & Ankle Society hindfoot score (92 points gravity-borderline group vs 93 points gravity-unstable group), the Foot Functional Index score (11 vs 10 points), the Short Form 36 (SF-36) physical component (86 vs 85 points), and SF-36 mental component (84 vs 81 points). Radiographically, all fractures had healed with anatomic congruity of the ankle. Weightbearing radiographs provided a reliable basis to decide about stability and nonoperative treatment in isolated lateral malleolar fractures of the SER type with excellent clinical and radiographic outcome at short-term follow-up. Gravity stress radiographs appear to overrate the need for operative treatment. Level III, prospective comparative study.

  14. Upright vs. Supine Radiographs of Clavicle Fractures: Does Positioning Matter?

    PubMed Central

    Backus, Jonathon D; Merriman, David J; McAndrew, Christopher M; Gardner, Michael J; Ricci, William M

    2014-01-01

    Objectives To determine if clavicle fracture displacement and shortening are different between upright and supine radiographic examinations. Design Combined retrospective and prospective comparative study. Setting Level I Trauma Center Patients Forty-six patients (mean age 49 years, range 24–89 years) with an acute clavicle fracture were evaluated. Intervention Standardized clavicle radiographs were obtained in both supine and upright positions for each patient. Displacement and shortening were measured and compared between the two positions. Main Outcomes Measurements One resident and three traumatologists classified the fractures and measured displacement and shortening. Data was aggregated and compared to ensure reliability with a two-way mixed intraclass correlation (ICC). Results Fracture displacement was significantly greater when measured from upright radiographs (15.9±8.9mm) than from supine radiographs (8.4±6.6mm, p<0.001), representing an 89% increase in displacement with upright positioning. Forty-one percent of patients had greater than 100% displacement on upright, but not on supine radiographs. Compared to the uninjured side, 3.0±10.7mm of shortening was noted on upright radiographs and 1.3±9.5mm of lengthening on supine radiographs (p<0.001). The ICC was 0.82 (95% CI: 0.73–0.89) for OTA fracture classification, 0.81 (95% CI: 0.75–0.87) for vertical displacement, and 0.92 (95% CI: 0.88–0.95) for injured clavicle length, demonstrating very high agreement among evaluators. Conclusions Increased fracture displacement and shortening was observed on upright compared to supine radiographs. This suggests that upright radiographs may better demonstrate clavicle displacement and predict the position at healing if nonoperative treatment is selected. PMID:24740113

  15. Bone stress: a radionuclide imaging perspective. [/sup 99m/Tc-pyrophosphate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roub, L.W.; Gumerman, L.W.; Hanley, E.N. Jr.

    Thirty-five college athletes with lower leg pain underwent radiography and radionuclide studies to rule out a stress fracture. Their asymptomatic extremities and 13 pain-free athletes served as controls. Four main patterns were observed: (a) sharply marginated scintigraphic abnormalities and positive radiographs; (b) sharply marginated scintigraphic abnormalities and negatives radiographs; (c) ill-defined scintigraphic abnormalities and negative radiographs; and (d) negative radionuclide images and negative radiographs. Since the patients with the first two patterns were otherwise identical medically, the authors feel that this scintigraphic appearance is characterisic of bone stress in the appropriate clinical setting, regardless of the radiographic findings. A schemamore » is proposed to explain the occurrence of positive radionuclide images and negative radiographs in the same patient, using a broad conceptual approach to the problem of bone stress.« less

  16. Radiographic identification of the equine ventral conchal bulla.

    PubMed

    Finnegan, C M; Townsend, N B; Barnett, T P; Barakzai, S Z

    Involvement of the ventral conchal sinus (VCS) is an important diagnostic and prognostic feature in cases of the equine sinus disease. The authors aimed to ascertain if the caudo-dorsal extension of the VCS, the ventral conchal bulla (VCB) is identifiable on plain radiographs of cadaver skulls without sinus disease. Bilateral frontonasal sinus flaps were made in 10 equine cadaver skulls. Plain lateral, lateral oblique and dorso-ventral radiographs were then obtained followed by the same views taken with stainless steel wire outlining the caudal border of the VCB. Plain radiographs were randomised and blindly evaluated by two observers who marked where they believed the VCB to be positioned. This was then correlated with the true position of the VCB using radiographs with wires in place. The ease of identification of the VCB was classified as 'easy' or 'difficult'. The VCB was correctly identified in 70 per cent of lateral radiographs, but only 45 per cent of lateral oblique radiographs and 17 per cent of dorso-ventral radiographs. If a clinician was confident that he or she could identify the VCB, they were usually correct. Conversely if the clinician judged VCB identification as 'difficult', they usually identified it incorrectly. In the authors' clinical experience, the VCB of horses with sinusitis involving this compartment is more radiologically evident than in clinically normal horses. Knowledge of the normal radiographic anatomy of this structure should aid clinicians in identifying horses with sinusitis affecting the VCS.

  17. Evaluation of radiographic, computed tomographic, and cadaveric anatomy of the head of boa constrictors.

    PubMed

    Banzato, Tommaso; Russo, Elisa; Di Toma, Anna; Palmisano, Giuseppe; Zotti, Alessandro

    2011-12-01

    To evaluate the radiographic, computed tomographic (CT), and cadaveric anatomy of the head of boa constrictors. 4 Boa constrictor imperator cadavers. Cadavers weighed 3.4 to 5.6 kg and had a body length ranging from 189 to 221 cm. Radiographic and CT images were obtained with a high-detail screen-film combination, and conventional CT was performed with a slice thickness of 1.5 mm. Radiographic images were obtained in ventrodorsal, dorsoventral, and left and right laterolateral recumbency; CT images were obtained with the animals positioned in ventral recumbency directly laying on a plastic support. At the end of the radiographic and CT imaging session, 2 heads were sectioned following a stratigraphic approach; the other 2, carefully maintained in the same position on the plastic support, were moved into a freezer (-20°C) until completely frozen and then sectioned into 3-mm slices, respecting the imaging protocol. The frozen sections were cleaned and then photographed on each side. Anatomic structures were identified and labeled on gross anatomic images and on the corresponding CT or radiographic image with the aid of available literature. Radiographic and CT images provided high detail for visualization of bony structures; soft tissues were not easily identified on radiographic and CT images. Results provide an atlas of stratigraphic and cross-sectional gross anatomy and radiographic and CT anatomy of the heads of boa constrictors that might be useful in the interpretation of any imaging modality in this species.

  18. Adult sail sign: radiographic and computed tomographic features.

    PubMed

    Lee, Yu-Jin; Han, Daehee; Koh, Young Hwan; Zo, Joo Hee; Kim, Sang-Hyun; Kim, Deog Kyeom; Lee, Jeong Sang; Moon, Hyeon Jong; Kim, Jong Seung; Chun, Eun Ju; Youn, Byung Jae; Lee, Chang Hyun; Kim, Sam Soo

    2008-02-01

    The sail sign is a well-known radiographic feature of the pediatric chest. This sign can be observed in an adult population as well, but for a different reason. To investigate the sail sign appearing in adult chest radiography. Based on two anecdotal adult cases in which frontal chest radiographs showed the sail sign, we prospectively screened radiographs of 10,238 patients to determine the incidence of the sail sign found in adults in their 40s or older. The cause of the sail sign was assessed using computed tomography (CT). The sail sign was revealed in 10 (seven males, three females; median age 60.6 years) of 10,238 patients. Of these 10 patients with a sail sign on frontal radiographs, eight underwent CT. The frontal radiographs of these 10 patients showed a concave superior margin toward the lung in nine patients, a concave inferior margin in five, and a double-lined inferior margin in three. Lateral radiographs disclosed a focal opacity over the minor fissure in five of six patients, which was either fuzzy (n = 4) or sharp (n = 1) in its upper margin, and was sometimes double lined in the inferior margin (n = 3). CT revealed the anterior mediastinal fat to be the cause of the radiographic sail sign, which stretched laterally from the mediastinum to insinuate into the minor fissure. The incidence of sail sign on adult chest radiographs is about 0.1%. The sign is specific enough to eliminate the need for more sophisticated imaging.

  19. Prevalence, distribution, and progression of radiographic abnormalities in the lungs of cold-stunned Kemp's ridley sea turtles (Lepidochelys kempii): 89 cases (2002-2005).

    PubMed

    Stockman, Jonathan; Innis, Charles J; Solano, Mauricio; O'Sullivan Brisson, Jennifer; Kass, Philip H; Tlusty, Michael F; Weber, E Scott

    2013-03-01

    To evaluate the prevalence, distribution, and progression of radiographic abnormalities in the lungs of cold-stunned Kemp's ridley sea turtles (Lepidochelys kempii) and associations between these abnormalities and body weight, carapace length, and hematologic and plasma biochemical variables. Retrospective case series. 89 cold-stunned juvenile Kemp's ridley sea turtles. Medical records were reviewed. Dorsoventral and horizontal beam craniocaudal radiographs were evaluated for the presence, distribution, and progression of lung abnormalities. Turtles were categorized as having radiographically normal or abnormal lungs; those with abnormalities detected were further categorized according to the distribution of abnormalities (left lung, right lung, or both affected). Body weight, carapace length, and hematologic and plasma biochemical data were compared among categories. 48 of 89 (54%) turtles had radiographic abnormalities of the lungs. Unilateral abnormalities of the right or left lung were detected in 14 (16%) and 2 (2%), respectively; both lungs were affected in 32 (36%). Prevalence of unilateral abnormalities was significantly greater for the right lung than for the left lung. Evaluation of follow-up radiographs indicated clinical improvement over time for most (18/31 [58%]) turtles. Prevalence of bilateral radiographic abnormalities was positively correlated with body weight and carapace length. There was no significant association between radiographic category and hematologic or plasma biochemical variables. Radiographic abnormalities of the lungs were commonly detected in cold-stunned Kemp's ridley turtles. Results of this study may aid clinicians in developing effective diagnostic and treatment plans for these patients.

  20. Repeat film analysis and its implications for quality assurance in dental radiology: An institutional case study

    PubMed Central

    Acharya, Shruthi; Pai, Keerthilatha M.; Acharya, Shashidhar

    2015-01-01

    Context: The goal of any radiologist is to produce the highest quality diagnostic radiographs, while keeping patient exposure as low as reasonably achievable (ALARA). Aims: The aim of this study was to describe the reasons for radiograph rejections through a repeat film analysis in an Indian dental school. Settings and Design: An observational study conducted in the Department of Oral Medicine and Radiology, Manipal College of Dental Sciences, Manipal. Materials and Methods: During a 6-month study period, a total of 9,495 intra-oral radiographs and 2339 extraoral radiographs taken in the Radiology Department were subjected to repeat film analysis. Statistical Analysis Used: SPSS Version 16. Descriptive analysis used. Results: The results showed that the repeat rates were 7.1% and 5.86% for intraoral and extraoral radiographs, respectively. Among the causes for errors reported, positioning error (38.7%) was the most common, followed by improper angulations (26.1%), and improper film placement (11.2%) for intra-oral radiographs. The study found that the maximum frequency of repeats among extraoral radiographs was for panoramic radiographs (49%) followed by lateral cephalogram (33%), and paranasal sinus view (14%). It was also observed that repeat rate of intraoral radiographs was highest for internees (44.7%), and undergraduate students (28.2%). Conclusions: The study pointed to a need for more targeted interventions to achieve the goal of keeping patient exposure ALARA in a dental school setting. PMID:26321841

  1. Comparative radiographic analysis on the anatomical axis in knee osteoarthritis cases: inter and intraobserver evaluation.

    PubMed

    Matos, Luiz Felipe; Giordano, Marcos; Cardoso, Gustavo Novaes; Farias, Rafael Baptista; E Albuquerque, Rodrigo Pires

    2015-01-01

    To make a comparative inter and intraobserver analysis on measurements of the anatomical axis between panoramic radiographs of the lower limbs in anteroposterior (AP) view with bipedal weight-bearing, on short film. An accuracy study comparing radiographic measurements on 47 knees of patients attending the knee surgery outpatient clinic due to osteoarthritis. The radiographic evaluation used was as standardized for the total knee arthroplasty program, including panoramic AP views of the lower limbs and short radiographs of the knees in AP and lateral views, all with bipedal weight-bearing. Following this, the anatomical axis of the lower limbs or the femorotibial angle was measured by five independent examiners on the panoramic and short AP radiographs; three of the examiners were considered to be more experienced and two, less experienced. All the measurements were made again by the same examiners after an interval of not less than 15 days. The statistical analysis was performed using the intraclass correlation coefficient, in order to evaluate the inter and intraobserver concordance of the anatomical axis measurements. From the statistical analysis, it was observed that there was strongly significant concordance between the anatomical axis measurements on the panoramic and short radiographs, for all the five examiners and for both measurements. Under the conditions studied, short radiographs were equivalent to panoramic radiographs for evaluating the anatomical axis of the lower limbs in patients with advanced osteoarthritis. The measurements used also showed high rates of inter and intraobserver concordance and reproducibility.

  2. Digital interactive learning of oral radiographic anatomy.

    PubMed

    Vuchkova, J; Maybury, T; Farah, C S

    2012-02-01

    Studies reporting high number of diagnostic errors made from radiographs suggest the need to improve the learning of radiographic interpretation in the dental curriculum. Given studies that show student preference for computer-assisted or digital technologies, the purpose of this study was to develop an interactive digital tool and to determine whether it was more successful than a conventional radiology textbook in assisting dental students with the learning of radiographic anatomy. Eighty-eight dental students underwent a learning phase of radiographic anatomy using an interactive digital tool alongside a conventional radiology textbook. The success of the digital tool, when compared to the textbook, was assessed by quantitative means using a radiographic interpretation test and by qualitative means using a structured Likert scale survey, asking students to evaluate their own learning outcomes from the digital tool. Student evaluations of the digital tool showed that almost all participants (95%) indicated that the tool positively enhanced their learning of radiographic anatomy and interpretation. The success of the digital tool in assisting the learning of radiographic interpretation is discussed in the broader context of learning and teaching curricula, and preference (by students) for the use of this digital form when compared to the conventional literate form of the textbook. Whilst traditional textbooks are still valued in the dental curriculum, it is evident that the preference for computer-assisted learning of oral radiographic anatomy enhances the learning experience by enabling students to interact and better engage with the course material. © 2011 John Wiley & Sons A/S.

  3. Assessment of radiation protection awareness and knowledge about radiological examination doses among Italian radiographers.

    PubMed

    Paolicchi, F; Miniati, F; Bastiani, L; Faggioni, L; Ciaramella, A; Creonti, I; Sottocornola, C; Dionisi, C; Caramella, D

    2016-04-01

    To evaluate radiation protection basic knowledge and dose assessment for radiological procedures among Italian radiographers A validated questionnaire was distributed to 780 participants with balanced demographic characteristics and geographic distribution. Only 12.1 % of participants attended radiation protection courses on a regular basis. Despite 90 % of radiographers stating to have sufficient awareness of radiation protection issues, most of them underestimated the radiation dose of almost all radiological procedures. About 5 % and 4 % of the participants, respectively, claimed that pelvis magnetic resonance imaging and abdominal ultrasound exposed patients to radiation. On the contrary, 7.0 % of the radiographers stated that mammography does not use ionising radiation. About half of participants believed that radiation-induced cancer is not dependent on age or gender and were not able to differentiate between deterministic and stochastic effects. Young radiographers (with less than 3 years of experience) showed a higher level of knowledge compared with the more experienced radiographers. There is a substantial need for radiographers to improve their awareness of radiation protection issues and their knowledge of radiological procedures. Specific actions such as regular training courses for both undergraduate and postgraduate students as well as for working radiographers must be considered in order to assure patient safety during radiological examinations. • Radiographers should improve their knowledge on radiation protection issues. • Only 12.1 % of participants attended radiation protection courses on a regular basis. • Specific actions must be considered in order to increase knowledge and awareness.

  4. Heterogeneous delivering capability promotes traffic efficiency in complex networks

    NASA Astrophysics Data System (ADS)

    Zhu, Yan-Bo; Guan, Xiang-Min; Zhang, Xue-Jun

    2015-12-01

    Traffic is one of the most fundamental dynamical processes in networked systems. With the homogeneous delivery capability of nodes, the global dynamic routing strategy proposed by Ling et al. [Phys. Rev. E81, 016113 (2010)] adequately uses the dynamic information during the process and thus it can reach a quite high network capacity. In this paper, based on the global dynamic routing strategy, we proposed a heterogeneous delivery allocation strategy of nodes on scale-free networks with consideration of nodes degree. It is found that the network capacity as well as some other indexes reflecting transportation efficiency are further improved. Our work may be useful for the design of more efficient routing strategies in communication or transportation systems.

  5. Simulation of noisy dynamical system by Deep Learning

    NASA Astrophysics Data System (ADS)

    Yeo, Kyongmin

    2017-11-01

    Deep learning has attracted huge attention due to its powerful representation capability. However, most of the studies on deep learning have been focused on visual analytics or language modeling and the capability of the deep learning in modeling dynamical systems is not well understood. In this study, we use a recurrent neural network to model noisy nonlinear dynamical systems. In particular, we use a long short-term memory (LSTM) network, which constructs internal nonlinear dynamics systems. We propose a cross-entropy loss with spatial ridge regularization to learn a non-stationary conditional probability distribution from a noisy nonlinear dynamical system. A Monte Carlo procedure to perform time-marching simulations by using the LSTM is presented. The behavior of the LSTM is studied by using noisy, forced Van der Pol oscillator and Ikeda equation.

  6. Improved fault ride through capability of DFIG based wind turbines using synchronous reference frame control based dynamic voltage restorer.

    PubMed

    Rini Ann Jerin, A; Kaliannan, Palanisamy; Subramaniam, Umashankar

    2017-09-01

    Fault ride through (FRT) capability in wind turbines to maintain the grid stability during faults has become mandatory with the increasing grid penetration of wind energy. Doubly fed induction generator based wind turbine (DFIG-WT) is the most popularly utilized type of generator but highly susceptible to the voltage disturbances in grid. Dynamic voltage restorer (DVR) based external FRT capability improvement is considered. Since DVR is capable of providing fast voltage sag mitigation during faults and can maintain the nominal operating conditions for DFIG-WT. The effectiveness of the DVR using Synchronous reference frame (SRF) control is investigated for FRT capability in DFIG-WT during both balanced and unbalanced fault conditions. The operation of DVR is confirmed using time-domain simulation in MATLAB/Simulink using 1.5MW DFIG-WT. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  7. Diagnostic value of chest radiographs in bedridden patients suspected of having pneumonia.

    PubMed

    Esayag, Yaacov; Nikitin, Irina; Bar-Ziv, Jacob; Cytter, Ruth; Hadas-Halpern, Irith; Zalut, Todd; Yinnon, Amos M

    2010-01-01

    To assess the diagnostic value of the chest radiograph for the diagnosis of pneumonia in bedridden patients, using non-contrast-enhanced high-resolution chest computed tomography (CT) as the gold standard. We prospectively evaluated bedridden patients hospitalized with moderate to high clinical probability of pneumonia. Chest radiographs were interpreted in a blinded fashion by 3 observers and classified as definite, normal, or uncertain for pneumonia. Chest CT was obtained within 12 hours of chest radiograph. We applied Bayesian analysis to assess the accuracy of chest radiograph in the diagnosis of pneumonia. In a 5-month period, 58 patients were evaluated, 31 (53%) were female. Their chest radiographs were interpreted as negative, uncertain, or positive for pneumonia in 31 (53%), 15 (26%), and 12 (21%) patients, respectively, while CT confirmed pneumonia in 11 (35%), 10 (67%), and in 10 (83%). The sensitivity of the chest radiograph to diagnose pneumonia was 65%, the specificity was 93%, the positive and negative predictive values were, respectively, 83% and 65%, while the overall accuracy was 69% (95% confidence interval, 50%-79%). In bedridden patients with suspected pneumonia, a normal chest radiograph does not rule out the diagnosis, hence, a chest CT scan might provide valuable diagnostic information. Copyright 2010 Elsevier Inc. All rights reserved.

  8. A retrospective study of radiographic abnormalities in the repositories for Thoroughbreds at yearling sales in Japan.

    PubMed

    Miyakoshi, Daisuke; Senba, Hiroyuki; Shikichi, Mitsumori; Maeda, Masaya; Shibata, Ryo; Misumi, Kazuhiro

    2017-11-10

    This study aimed to evaluate whether radiographic abnormalities at yearling sales were associated with the failure to start racing at 2-3 years of age. Radiographic abnormalities in the carpal (n=852), tarsal (n=976), metacarpophalangeal (n=1,055), and metatarsophalangeal joints (n=1,031) from 1,082 horses, recorded at yearling sale, were reviewed. Eighty-two horses (7.6%) failed to start racing. Radiographic abnormalities such as wedged or collapsed tarsal bones, irregular lucency of a sagittal ridge at the distal aspect of the distal third metatarsal bone, and proximal dorsal fragmentation of the first phalanx in metatarsophalangeal joints were associated with failure to start racing in these horses. In the follow-up survey of 12 horses with one or more these radiographic abnormalities, the horses failed to start racing due to reasons unrelated to these radiographic abnormalities such as pelvic fractures (2 horses), fracture of a distal phalanx (1 horse), cervical stenotic myelopathy and proximal sesamoid fracture (1 horse), superficial digital flexor tendonitis (2 horses), laryngeal hemiplegia (1 horse), economic problems (2 horses) and unknown causes (3 horses). Although radiographic abnormalities at yearling sales can be associated with failure to start racing at 2-3 years of age, these radiographically detected abnormalities might not necessarily cause that failure.

  9. Validity of radiographic assessment of the knee joint space using automatic image analysis.

    PubMed

    Komatsu, Daigo; Hasegawa, Yukiharu; Kojima, Toshihisa; Seki, Taisuke; Ikeuchi, Kazuma; Takegami, Yasuhiko; Amano, Takafumi; Higuchi, Yoshitoshi; Kasai, Takehiro; Ishiguro, Naoki

    2016-09-01

    The present study investigated whether there were differences between automatic and manual measurements of the minimum joint space width (mJSW) on knee radiographs. Knee radiographs of 324 participants in a systematic health screening were analyzed using the following three methods: manual measurement of film-based radiographs (Manual), manual measurement of digitized radiographs (Digital), and automatic measurement of digitized radiographs (Auto). The mean mJSWs on the medial and lateral sides of the knees were determined using each method, and measurement reliability was evaluated using intra-class correlation coefficients. Measurement errors were compared between normal knees and knees with radiographic osteoarthritis. All three methods demonstrated good reliability, although the reliability was slightly lower with the Manual method than with the other methods. On the medial and lateral sides of the knees, the mJSWs were the largest in the Manual method and the smallest in the Auto method. The measurement errors of each method were significantly larger for normal knees than for radiographic osteoarthritis knees. The mJSW measurements are more accurate and reliable with the Auto method than with the Manual or Digital method, especially for normal knees. Therefore, the Auto method is ideal for the assessment of the knee joint space.

  10. The value of radiographs obtained during forced traction under general anaesthesia in predicting flexibility in idiopathic scoliosis with Cobb angles exceeding 60 degree.

    PubMed

    Ibrahim, T; Gabbar, O A; El-Abed, K; Hutchinson, M J; Nelson, I W

    2008-11-01

    Our aim in this prospective radiological study was to determine whether the flexibility rate calculated from radiographs obtained during forced traction under general anaesthesia, was better than that of fulcrum-bending radiographs before corrective surgery in predicting the extent of the available correction in patients with idiopathic scoliosis. We evaluated 33 patients with a Cobb angle > 60 degrees on a standing posteroanterior radiograph, who had been treated by posterior correction. Pre-operative standing fulcrum-bending radiographs and those with forced-traction under general anaesthesia were obtained. Post-operative standing radiographs were taken after surgical correction. The mean forced-traction flexibility rate was 55% (SD 11.3) which was significantly higher than the mean fulcrum-bending flexibility rate of 32% (SD 16.1) (p < 0.001). We found no correlation between either the forced-traction or fulcrum-bending flexibility rates and the correction rate post-operatively (p = 0.24 and p = 0.44, respectively). Radiographs obtained during forced traction under general anaesthesia were better at predicting the flexibility of the curve than fulcrum-bending radiographs in curves with a Cobb angle > 60 degrees in the standing position and may identify those patients for whom supplementary anterior surgery can be avoided.

  11. Method for minimizing the radiation exposure from scoliosis radiographs. [X ray

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Smet, A.A.; Fritz, S.L.; Asher, M.A.

    1981-01-01

    The radiation exposure resulting from standard scoliosis radiographs was determined for eighteen adolescent girls. The risk of inducing breast cancer was estimated from the skin-exposure doses. The average skin exposure to the breasts was 59.6 millirads (0.59 mGy) for the anteroposterior radiograph. Assuming a total of twenty-two anteroposterior radiographs during a course of treatment, the cumulative exposure would result in a 1.35% relative increase in the risk of development of breast cancer. By utilizing collimation of the x-ray beam and proper selection of grids, films, and screens, the radiation risk of scoliosis radiographs is minimized.

  12. 21 CFR 892.1850 - Radiographic film cassette.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) Identification. A radiographic film cassette is a device intended for use during diagnostic x-ray procedures to hold a radiographic film in close contact with an x-ray intensifying screen and to provide a light...

  13. Automatic image hanging protocol for chest radiographs in PACS.

    PubMed

    Luo, Hui; Hao, Wei; Foos, David H; Cornelius, Craig W

    2006-04-01

    Chest radiography is one of the most widely used techniques in diagnostic imaging. It comprises at least one-third of all diagnostic radiographic procedures in hospitals. However, in the picture archive and communication system, images are often stored with the projection and orientation unknown or mislabeled, which causes inefficiency for radiologists' interpretation. To address this problem, an automatic hanging protocol for chest radiographs is presented. The method targets the most effective region in a chest radiograph, and extracts a set of size-, rotation-, and translation-invariant features from it. Then, a well-trained classifier is used to recognize the projection. The orientation of the radiograph is later identified by locating the neck, heart, and abdomen positions in the radiographs. Initial experiments are performed on the radiographs collected from daily routine chest exams in hospitals and show promising results. Using the presented protocol, 98.2% of all cases could be hung correctly on projection view (without protocol, 62%), and 96.1% had correct orientation (without protocol, 75%). A workflow study on the protocol also demonstrates a significant improvement in efficiency for image display.

  14. The 'ABC' of examining foot radiographs.

    PubMed

    Pearse, Eyiyemi O; Klass, Benjamin; Bendall, Stephen P

    2005-11-01

    We report a simple systematic method of assessing foot radiographs that improves diagnostic accuracy and can reduce the incidence of inappropriate management of serious forefoot and midfoot injuries, particularly the Lisfranc-type injury. Five recently appointed senior house officers (SHOs), with no casualty or Orthopaedic experience prior to their appointment, were shown a set of 10 foot radiographs and told the history and examination findings recorded in the casualty notes of each patient within 6 weeks of taking up their posts. They were informed that the radiographs might or might not demonstrate an abnormality. They were asked to make a diagnosis and decide on a management plan. The test was repeated after they were taught the 'ABC' method of evaluating foot radiographs. Diagnostic accuracy improved after SHOs were taught a systematic method of assessing foot radiographs. The proportion of correct diagnoses increased from 0.64 to 0.78 and the probability of recognising Lisfranc injuries increased from 0 to 0.6. The use of this simple method of assessing foot radiographs can reduce the incidence of inappropriate management of serious foot injuries by casualty SHOs, in particular the Lisfranc type injury.

  15. [The Relation between the Height of Radiographic Table and Workloads of Radiologic Technologist in General X-ray Examinations].

    PubMed

    Hattori, Akiko; Mizoguchi, Noriko; Arimura, Hisao; Fukano, Yuuichi; Umezu, Yoshiyuki; Yabuuchi, Hidetake

    2015-12-01

    Workloads of radiological technologists under different conditions of heights of radiographic table and/or X-ray tube assembly were calculated using a software for preventing musculoskeletal complaint to investigate optimal working environment for general X-ray examinations. In the patient positioning, compressive force of lumbar disc decreased at higher radiographic table within the range of 45-90 cm. On the other hand, workload of the shoulder joint increased with increase in the height of radiographic table. Load of the shoulder joint similarly increased as the height of the X-ray tube assembly increased. Compressive force of lumbar disc reduced by approximately 10-30% as the height ratio of the radiographic table to body height increased by approximately 40%, compared to the lowest table of 45 cm. Muscle load of a 50-years-old woman was approximately double compared to a 30-year-old man, even in the same workload. It is important to keep suitable height of radiographic table for reduction of the workloads of lumbar rather than shoulder joint, because floating-type radiographic table is generally used.

  16. Correction of radiographic measurements of acetabular cup wear for variations in pelvis orientation.

    PubMed

    Derbyshire, Brian

    2018-03-01

    Radiographic measurement of two-dimensional acetabular cup wear is usually carried out on a series of follow-up radiographs of the patient's pelvis. Since the orientation of the pelvis might not be consistent at every X-ray examination, the resulting change in view of the wear plane introduces error into the linear wear measurement. This effect is amplified on some designs of cup in which the centre of the socket is several millimetres below the centre of the cup or circular wire marker. This study describes the formulation of a mathematical method to correct radiographic wear measurements for changes in pelvis orientation. A mathematical simulation of changes in cup orientation and wear vectors caused by pelvic tilt was used to confirm that the formulae corrected the wear exactly if the radiographic plane of the reference radiograph was parallel to the true plane of wear. An error analysis showed that even when the true wear plane was not parallel to the reference radiographic plane, the formulae could still provide a useful correction. A published correction formula was found to be ineffective.

  17. Correction of radiographic measurements of acetabular cup wear for variations in pelvis orientation

    PubMed Central

    Derbyshire, Brian

    2018-01-01

    Radiographic measurement of two-dimensional acetabular cup wear is usually carried out on a series of follow-up radiographs of the patient’s pelvis. Since the orientation of the pelvis might not be consistent at every X-ray examination, the resulting change in view of the wear plane introduces error into the linear wear measurement. This effect is amplified on some designs of cup in which the centre of the socket is several millimetres below the centre of the cup or circular wire marker. This study describes the formulation of a mathematical method to correct radiographic wear measurements for changes in pelvis orientation. A mathematical simulation of changes in cup orientation and wear vectors caused by pelvic tilt was used to confirm that the formulae corrected the wear exactly if the radiographic plane of the reference radiograph was parallel to the true plane of wear. An error analysis showed that even when the true wear plane was not parallel to the reference radiographic plane, the formulae could still provide a useful correction. A published correction formula was found to be ineffective. PMID:29473454

  18. Bone texture analysis on dental radiographic images: results with several angulated radiographs on the same region of interest

    NASA Astrophysics Data System (ADS)

    Amouriq, Yves; Guedon, Jeanpierre; Normand, Nicolas; Arlicot, Aurore; Benhdech, Yassine; Weiss, Pierre

    2011-03-01

    Bone microarchitecture is the predictor of bone quality or bone disease. It can only be measured on a bone biopsy, which is invasive and not available for all clinical situations. Texture analysis on radiographs is a common way to investigate bone microarchitecture. But relationship between three-dimension histomorphometric parameters and two-dimension texture parameters is not always well known, with poor results. The aim of this study is to performed angulated radiographs of the same region of interest and see if a better relationship between texture analysis on several radiographs and histomorphometric parameters can be developed. Computed radiography images of dog (Beagle) mandible section in molar regions were compared with high-resolution micro-CT (Computed-Tomograph) volumes. Four radiographs with 27° angle (up, down, left, right, using Rinn ring and customized arm positioning system) were performed from initial radiograph position. Bone texture parameters were calculated on all images. Texture parameters were also computed from new images obtained by difference between angulated images. Results of fractal values in different trabecular areas give some caracterisation of bone microarchitecture.

  19. Dynamic Analytical Capability to Better Understand and Anticipate Extremist Shifts Within Populations under Authoritarian Regimes.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernard, Michael Lewis

    2015-11-01

    The purpose of this work is to create a generalizable data- and theory-supported capability to better understand and anticipate (with quantifiable uncertainty): 1) how the dynamics of allegiance formations between various groups and society are impacted by active conflict and by third-party interventions and 2) how/why extremist allegiances co-evolve over time due to changing geopolitical, sociocultural, and military conditions.

  20. Dynamic Range Enhancement of High-Speed Electrical Signal Data via Non-Linear Compression

    NASA Technical Reports Server (NTRS)

    Laun, Matthew C. (Inventor)

    2016-01-01

    Systems and methods for high-speed compression of dynamic electrical signal waveforms to extend the measuring capabilities of conventional measuring devices such as oscilloscopes and high-speed data acquisition systems are discussed. Transfer function components and algorithmic transfer functions can be used to accurately measure signals that are within the frequency bandwidth but beyond the voltage range and voltage resolution capabilities of the measuring device.

  1. SpecTAD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zamora, Richard; Voter, Arthur; Uberuaga, Bla

    2017-10-23

    The SpecTAD software represents a refactoring of the Temperature Accelerated Dynamics (TAD2) code authored by Arthur F. Voter and Blas P. Uberuaga (LA-CC-02-05). SpecTAD extends the capabilities of TAD2, by providing algorithms for both temporal and spatial parallelism. The novel algorithms for temporal parallelism include both speculation and replication based techniques. SpecTAD also offers the optional capability to dynamically link to the open-source LAMMPS package.

  2. Spectral Dynamics Inc., ships hybrid, 316-channel data acquisition system to Sandia Labs.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwartz, Douglas

    2003-09-01

    Spectral Dynamics announced the shipment of a 316-channel data acquisition system. The system was custom designed for the Light Initiated High Explosive (LIHE) facility at Sandia Labs in Albuquerque, New Mexico by Spectral Dynamics Advanced Research Products Group. This Spectral Dynamics data acquisition system was tailored to meet the unique LIHE environmental and testing requirements utilizing Spectral Dynamics commercial off the shelf (COTS) Jaguar and VIDAS products supplemented by SD Alliance partner's (COTS) products. 'This system is just the beginning of our cutting edge merged technology solutions,' stated Mark Remelman, Manager for the Spectral Dynamics Advanced Research Products Group. 'Thismore » Hybrid system has 316-channels of data acquisition capability, comprised of 102.4kHz direct to disk acquisition and 2.5MHz, 200Mhz & 500Mhz RAM based capabilities. In addition it incorporates the advanced bridge conditioning and dynamic configuration capabilities offered by Spectral Dynamics new Smart Interface Panel System (SIPS{trademark}).' After acceptance testing, Tony King, the Instrumentation Engineer facilitating the project for the Sandia LIHE group commented; 'The LIHE staff was very impressed with the design, construction, attention to detail and overall performance of the instrumentation system'. This system combines VIDAS, a leading edge fourth generation SD-VXI hardware and field-proven software system from SD's Advanced Research Products Group with SD's Jaguar, a multiple Acquisition Control Peripheral (ACP) system that allows expansion to hundreds of channels without sacrificing signal processing performance. Jaguar incorporates dedicated throughput disks for each ACP providing time streaming to disk at up to the maximum sample rate. Spectral Dynamics, Inc. is a leading worldwide supplier of systems and software for advanced computer-automated data acquisition, vibration testing, structural dynamics, explosive shock, high-speed transient capture, acoustic analysis, monitoring, measurement, control and backup. Spectral Dynamics products are used for research, design verification, product testing and process improvement by manufacturers of all types of electrical, electronic and mechanical products, as well as by universities and government-funded agencies. The Advanced Research Products Group is the newest addition to the Spectral Dynamics family. Their newest VXI data acquisition hardware pushes the envelope on capabilities and embodies the same rock solid design methodologies, which have always differentiated Spectral Dynamics from its competition.« less

  3. The Next Generation of High-Speed Dynamic Stability Wind Tunnel Testing (Invited)

    NASA Technical Reports Server (NTRS)

    Tomek, Deborah M.; Sewall, William G.; Mason, Stan E.; Szchur, Bill W. A.

    2006-01-01

    Throughout industry, accurate measurement and modeling of dynamic derivative data at high-speed conditions has been an ongoing challenge. The expansion of flight envelopes and non-conventional vehicle design has greatly increased the demand for accurate prediction and modeling of vehicle dynamic behavior. With these issues in mind, NASA Langley Research Center (LaRC) embarked on the development and shakedown of a high-speed dynamic stability test technique that addresses the longstanding problem of accurately measuring dynamic derivatives outside the low-speed regime. The new test technique was built upon legacy technology, replacing an antiquated forced oscillation system, and greatly expanding the capabilities beyond classic forced oscillation testing at both low and high speeds. The modern system is capable of providing a snapshot of dynamic behavior over a periodic cycle for varying frequencies, not just a damping derivative term at a single frequency.

  4. Techniques for animation of CFD results. [computational fluid dynamics

    NASA Technical Reports Server (NTRS)

    Horowitz, Jay; Hanson, Jeffery C.

    1992-01-01

    Video animation is becoming increasingly vital to the computational fluid dynamics researcher, not just for presentation, but for recording and comparing dynamic visualizations that are beyond the current capabilities of even the most powerful graphic workstation. To meet these needs, Lewis Research Center has recently established a facility to provide users with easy access to advanced video animation capabilities. However, producing animation that is both visually effective and scientifically accurate involves various technological and aesthetic considerations that must be understood both by the researcher and those supporting the visualization process. These considerations include: scan conversion, color conversion, and spatial ambiguities.

  5. A Government/Industry Summary of the Design Analysis Methods for Vibrations (DAMVIBS) Program

    NASA Technical Reports Server (NTRS)

    Kvaternik, Raymond G. (Compiler)

    1993-01-01

    The NASA Langley Research Center in 1984 initiated a rotorcraft structural dynamics program, designated DAMVIBS (Design Analysis Methods for VIBrationS), with the objective of establishing the technology base needed by the rotorcraft industry for developing an advanced finite-element-based dynamics design analysis capability for vibrations. An assessment of the program showed that the DAMVIBS Program has resulted in notable technical achievements and major changes in industrial design practice, all of which have significantly advanced the industry's capability to use and rely on finite-element-based dynamics analyses during the design process.

  6. Pes planus: radiographic changes with foot orthoses and shoes.

    PubMed

    Penneau, K; Lutter, L D; Winter, R D

    1982-03-01

    Radiographic evaluation of 10 children with bilateral pes planus was performed. Radiographs taken barefoot, with a Thomas heel, with an over-the-counter insert, with two specially molded plastic foot orthoses were used. No significant change was seen after the donning of these appliances in their comparison to barefoot evaluation. The conclusion is that there was not a significant change radiographically of these feet by the utilization of any of the appliances.

  7. Radiographic and ultrasonographic characteristics of ventral abdominal hernia in pigeons (Columba livia).

    PubMed

    Amer, Mohammed S; Hassan, Elham A; Torad, Faisal A

    2018-02-20

    Five female egg-laying pigeons presented with painless, reducible, ventral abdominal swellings located between the keel and the pubis, or close to the cloaca. Based on clinical, radiographic, and ultrasonographic examination, these pigeons were diagnosed with ventral abdominal hernia requiring surgical interference. Reduction was successfully performed under general anesthesia. Radiographic and ultrasonographic examinations were beneficial for confirming the diagnosis and visualizing the hernial content for surgical planning. Lateral radiographs were more helpful than ventrodorsal radiographs for identification of the hernial content and its continuation with the abdominal muscles. Ultrasonographic examination offered a non-invasive diagnostic tool that allowed for the differentiation of hernia from other abdominal swellings. In addition, it played a beneficial role in identification of the hernial content and follow up after surgical interference. In conclusion, radiographic and ultrasonographic examinations were beneficial in the diagnosis, surgical planning, and follow up after surgical interference of ventral abdominal hernia in pigeons.

  8. Vertical or horizontal orientation of foot radiographs does not affect image interpretation

    PubMed Central

    Ferran, Nicholas Antonio; Ball, Luke; Maffulli, Nicola

    2012-01-01

    Summary This study determined whether the orientation of dorsoplantar and oblique foot radiographs has an effect on radiograph interpretation. A test set of 50 consecutive foot radiographs were selected (25 with fractures, and 25 normal), and duplicated in the horizontal orientation. The images were randomly arranged, numbered 1 through 100, and analysed by six image interpreters. Vertical and horizontal area under the ROC curve, accuracy, sensitivity and specificity were calculated for each image interpreter. There was no significant difference in the area under the ROC curve, accuracy, sensitivity or specificity of image interpretation between images viewed in the vertical or horizontal orientation. While conventions for display of radiographs may help to improve the development of an efficient visual search strategy in trainees, and allow for standardisation of publication of radiographic images, variation from the convention in clinical practice does not appear to affect the sensitivity or specificity of image interpretation. PMID:23738310

  9. Automated method and system for the alignment and correlation of images from two different modalities

    DOEpatents

    Giger, Maryellen L.; Chen, Chin-Tu; Armato, Samuel; Doi, Kunio

    1999-10-26

    A method and system for the computerized registration of radionuclide images with radiographic images, including generating image data from radiographic and radionuclide images of the thorax. Techniques include contouring the lung regions in each type of chest image, scaling and registration of the contours based on location of lung apices, and superimposition after appropriate shifting of the images. Specific applications are given for the automated registration of radionuclide lungs scans with chest radiographs. The method in the example given yields a system that spatially registers and correlates digitized chest radiographs with V/Q scans in order to correlate V/Q functional information with the greater structural detail of chest radiographs. Final output could be the computer-determined contours from each type of image superimposed on any of the original images, or superimposition of the radionuclide image data, which contains high activity, onto the radiographic chest image.

  10. Methods employed for chest radiograph interpretation education for radiographers: A systematic review of the literature.

    PubMed

    McLaughlin, L; McConnell, J; McFadden, S; Bond, R; Hughes, C

    2017-11-01

    This systematic review aimed to determine the strength of evidence available in the literature on the effect of training to develop the skills required by radiographers to interpret plain radiography chest images. Thirteen articles feature within the review. Sample size varied from one reporting radiographer to 148 radiography students/experienced radiographers. The quality of the articles achieved a mean score of 7.5/10, indicating the evidence is strong and the quality of studies in this field is high. Investigative approaches included audit of participants' performance in clinical practice post formal training, evaluation of informal training and the impact of short feedback sessions on performance. All studies demonstrated positive attributions on user performance. Using a combination of training techniques can help maximise learning and accommodate those with different preferred learning types. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  11. TU-D-209-06: Head and Neck Tissue Dose From X-Ray Scatter to Physicians Performing Cardiovascular Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fetterly, K; Schueler, B; Grams, M

    Purpose: The purpose of this work was to characterize the spatial distribution of scatter radiation to the head and neck of a physician performing an x-ray interventional procedure and assess brain, eye lens, and carotid artery dose. Methods: Radiographic x-ray beams were tuned to match the peak energy (56 to 106 keV) and HVL (3.5 to 6.5 mm Al) of x-ray scatter originating from a patient during a fluoroscopic procedure. The radiographic beam was directed upon a Rando phantom from an inferior-left location to mimic a typical patient-operator geometric relationship. A lead-equivalent protective garment was secured to the phantom. Directmore » exposure Gafchromic film (XRQA2) was placed between the transverse plane layers of the head and neck region of the phantom and exposed with 4 scatter-equivalent radiographic beams. A 3×3 cm{sup 2} film placed at the left collar of the phantom was used to monitor incident dose in the position of a radiation monitoring badge. The films were converted to 2D dose distribution maps using FilmQA Pro software and an Epson 11000-XL scanner. The 2D dose distributions maps were normalized by the left collar dose and the percent of left collar dose (%LCD) was calculated for select tissues. Results: The dose maps had high dynamic range (10{sub 4}) and spatial detail. Considering all transverse planes and 4 scatter beam qualities, the median %LCD values were: whole brain 8.5%, left brain 13%, right brain 5.4%, left eye lens 67%, right eye lens 25%, left carotid artery 72%, and right carotid artery 28%. Conclusion: Scatter radiation dose to an operator can be simulated using a tuned radiographic beam and used to expose a phantom and Gafchromic film, thereby creating detailed 2D dose distribution maps. This work facilitates individualized estimation of dose to select head and neck tissues based on an operator’s radiation monitoring badge value.« less

  12. SU-E-I-90: Characterizing Small Animal Lung Properties Using Speckle Observed with An In-Line X-Ray Phase Contrast Benchtop System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garson, A; Gunsten, S; Guan, H

    Purpose: We demonstrate a novel X-ray phase-contrast (XPC) method for lung imaging representing a paradigm shift in the way small animal functional imaging is performed. In our method, information regarding airway microstructure that is encoded within speckle texture of a single XPC radiograph is decoded to produce 2D parametric images that will spatially resolve changes in lung properties such as microstructure sizes and air volumes. Such information cannot be derived from conventional lung radiography or any other 2D imaging modality. By computing these images at different points within a breathing cycle, dynamic functional imaging will be readily achieved without themore » need for tomography. Methods: XPC mouse lung radiographs acquired in situ with an in-line X-ray phase contrast benchtop system. The lung air volume is varied and controlled with a small animal ventilator. XPC radiographs will be acquired for various lung air volume levels representing different phases of the respiratory cycle. Similar data will be acquired of microsphere-based lung phantoms containing hollow glass spheres with known distributions of diameters. Image texture analysis is applied to the data to investigate relationships between texture characteristics and airspace/microsphere physical properties. Results: Correlations between Fourier-based texture descriptors (FBTDs) and regional lung air volume indicate that the texture features in 2D radiographs reveal information on 3D properties of the lungs. For example, we find for a 350 × 350 πm2 lung ROI a linear relationship between injected air volume and FBTD value with slope and intercept of 8.9×10{sup 5} and 7.5, respectively. Conclusion: We demonstrate specific image texture measures related to lung speckle features are correlated with physical characteristics of refracting elements (i.e. lung air spaces). Furthermore, we present results indicating the feasibility of implementing the technique with a simple imaging system design, short exposures, and low dose which provides potential for widespread use in laboratory settings for in vivo studies. This research was supported in part by NSF Award CBET1263988.« less

  13. Chest radiographs for acute lower respiratory tract infections.

    PubMed

    Cao, Amy Millicent Y; Choy, Joleen P; Mohanakrishnan, Lakshmi Narayana; Bain, Roger F; van Driel, Mieke L

    2013-12-26

    Acute lower respiratory tract infections (LRTIs) (e.g. pneumonia) are a major cause of morbidity and mortality and management focuses on early treatment. Chest radiographs (X-rays) are one of the commonly used strategies. Although radiological facilities are easily accessible in high-income countries, access can be limited in low-income countries. The efficacy of chest radiographs as a tool in the management of acute LRTIs has not been determined. Although chest radiographs are used for both diagnosis and management, our review focuses only on management. To assess the effectiveness of chest radiographs in addition to clinical judgement, compared to clinical judgement alone, in the management of acute LRTIs in children and adults. We searched CENTRAL 2013, Issue 1; MEDLINE (1948 to January week 4, 2013); EMBASE (1974 to February 2013); CINAHL (1985 to February 2013) and LILACS (1985 to February 2013). We also searched NHS EED, DARE, ClinicalTrials.gov and WHO ICTRP (up to February 2013). Randomised controlled trials (RCTs) of chest radiographs versus no chest radiographs in acute LRTIs in children and adults. Two review authors independently applied the inclusion criteria, extracted data and assessed risk of bias. A third review author compiled the findings and any discrepancies were discussed among all review authors. We used the standard methodological procedures expected by The Cochrane Collaboration. Two RCTs involving 2024 patients (1502 adults and 522 children) were included in this review. Both RCTs excluded patients with suspected severe disease. It was not possible to pool the results due to incomplete data. Both included trials concluded that the use of chest radiographs did not result in a better clinical outcome (duration of illness and of symptoms) for patients with acute LRTIs. In the study involving children in South Africa, the median time to recovery was seven days (95% confidence interval (CI) six to eight days (radiograph group) and six to nine days (control group)), P value = 0.50, log-rank test) and the hazard ratio for recovery was 1.08 (95% CI 0.85 to 1.34). In the study with adult participants in the USA, the average duration of illness was 16.9 days versus 17.0 days (P value > 0.05) in the radiograph and no radiograph groups respectively. This result was not statistically significant and there were no significant differences in patient outcomes between the groups with or without chest radiograph.The study in adults also reports that chest radiographs did not affect the frequencies with which clinicians ordered return visits or antibiotics. However, there was a benefit of chest radiographs in a subgroup of the adult participants with an infiltrate on their radiograph, with a reduction in length of illness (16.2 days in the group allocated to chest radiographs and 22.6 in the non-chest radiograph group, P < 0.05), duration of cough (14.2 versus 21.3 days, P < 0.05) and duration of sputum production (8.5 versus 17.8 days, P < 0.05). The authors mention that this difference in outcome between the intervention and control group in this particular subgroup only was probably a result of "the higher proportion of patients treated with antibiotics when the radiograph was used in patient care".Hospitalisation rates were only reported in the study involving children and it was found that a higher proportion of patients in the radiograph group (4.7%) required hospitalisation compared to the control group (2.3%) with the result not being statistically significant (P = 0.14). None of the trials report the effect on mortality, complications of infection or adverse events from chest radiographs. Overall, the included studies had a low or unclear risk for blinding, attrition bias and reporting bias, but a high risk of selection bias. Both trials had strict exclusion criteria which is important but may limit the clinical practicability of the results as participants may not reflect those presenting in clinical practice. Data from two trials suggest that routine chest radiography does not affect the clinical outcomes in adults and children presenting to a hospital with signs and symptoms suggestive of a LRTI. This conclusion may be weakened by the risk of bias of the studies and the lack of complete data available.

  14. Reestablishment of radiographic kidney size in Miniature Schnauzer dogs

    PubMed Central

    SOHN, Jungmin; YUN, Sookyung; LEE, Jeosoon; CHANG, Dongwoo; CHOI, Mincheol; YOON, Junghee

    2016-01-01

    Kidney size may be altered in renal diseases, and the detection of kidney size alteration has diagnostic and prognostic values. We hypothesized that radiographic kidney size, the kidney length to the second lumbar vertebra (L2) length ratio, in normal Miniature Schnauzer dogs may be overestimated due to their shorter vertebral length. This study was conducted to evaluate radiographic and ultrasonographic kidney size and L2 length in clinically normal Miniature Schnauzers and other dog breeds to evaluate the effect of vertebral length on radiographic kidney size and to reestablish radiographic kidney size in normal Miniature Schnauzers. Abdominal radiographs and ultrasonograms from 49 Miniature Schnauzers and 54 other breeds without clinical evidence of renal disease and lumbar vertebral abnormality were retrospectively evaluated. Radiographic kidney size, in the Miniature Schnauzer (3.31 ± 0.26) was significantly larger than that in other breeds (2.94 ± 0.27). Relative L2 length, the L2 length to width ratio, in the Miniature Schnauzer (1.11 ± 0.06) was significantly shorter than that in other breeds (1.21 ± 0.09). However, ultrasonographic kidney sizes, kidney length to aorta diameter ratios, were within or very close to normal range both in the Miniature Schnauzer (6.75 ± 0.67) and other breeds (7.16 ± 1.01). Thus, Miniature Schnauzer dogs have breed-specific short vertebrae and consequently a larger radiographic kidney size, which was greater than standard reference in normal adult dogs. Care should be taken when evaluating radiographic kidney size in Miniature Schnauzers to prevent falsely diagnosed renomegaly. PMID:27594274

  15. Radiographic evaluation of bone adaptation adjacent to percutaneous osseointegrated prostheses in a sheep model.

    PubMed

    Jeyapalina, Sujee; Beck, James Peter; Bachus, Kent N; Chalayon, Ornusa; Bloebaum, Roy D

    2014-10-01

    Percutaneous osseointegrated prostheses (POPs) are being investigated as an alternative to conventional socket suspension and require a radiographic followup in translational studies to confirm that design objectives are being met. In this 12-month animal study, we determined (1) radiographic signs of osseointegration and (2) radiographic signs of periprosthetic bone hypertrophy and resorption (adaptation) and (3) confirmed them with the histologic evidence of host bone osseointegration and adaptation around a novel, distally porous-coated titanium POP with a collar. A POP device was designed to fit the right metacarpal bone of sheep. Amputation and implantation surgeries (n = 14) were performed, and plane-film radiographs were collected quarterly for 12 months. Radiographs were assessed for osseointegration (fixation) and bone adaptation (resorption and hypertrophy). The cortical wall and medullary canal widths were used to compute the cortical index and expressed as a percentage. Based on the cortical index changes and histologic evaluations, bone adaptation was quantified. Radiographic data showed signs of osseointegration including those with incomplete seating against the collar attachment. Cortical index data indicated distal cortical wall thinning if the collar was not seated distally. When implants were bound proximally, bone resorbed distally and the diaphyseal cortex hypertrophied. Histopathologic evidence and cortical index measurements confirmed the radiographic indications of adaptation and osseointegration. Distal bone loading, through collar attachment and porous coating, limited the distal bone resorption. Serial radiographic studies, in either animal models or preclinical trials for new POP devices, will help to determine which designs are likely to be safe over time and avoid implant failures.

  16. Reestablishment of radiographic kidney size in Miniature Schnauzer dogs.

    PubMed

    Sohn, Jungmin; Yun, Sookyung; Lee, Jeosoon; Chang, Dongwoo; Choi, Mincheol; Yoon, Junghee

    2017-01-10

    Kidney size may be altered in renal diseases, and the detection of kidney size alteration has diagnostic and prognostic values. We hypothesized that radiographic kidney size, the kidney length to the second lumbar vertebra (L2) length ratio, in normal Miniature Schnauzer dogs may be overestimated due to their shorter vertebral length. This study was conducted to evaluate radiographic and ultrasonographic kidney size and L2 length in clinically normal Miniature Schnauzers and other dog breeds to evaluate the effect of vertebral length on radiographic kidney size and to reestablish radiographic kidney size in normal Miniature Schnauzers. Abdominal radiographs and ultrasonograms from 49 Miniature Schnauzers and 54 other breeds without clinical evidence of renal disease and lumbar vertebral abnormality were retrospectively evaluated. Radiographic kidney size, in the Miniature Schnauzer (3.31 ± 0.26) was significantly larger than that in other breeds (2.94 ± 0.27). Relative L2 length, the L2 length to width ratio, in the Miniature Schnauzer (1.11 ± 0.06) was significantly shorter than that in other breeds (1.21 ± 0.09). However, ultrasonographic kidney sizes, kidney length to aorta diameter ratios, were within or very close to normal range both in the Miniature Schnauzer (6.75 ± 0.67) and other breeds (7.16 ± 1.01). Thus, Miniature Schnauzer dogs have breed-specific short vertebrae and consequently a larger radiographic kidney size, which was greater than standard reference in normal adult dogs. Care should be taken when evaluating radiographic kidney size in Miniature Schnauzers to prevent falsely diagnosed renomegaly.

  17. Radiographic Study of Haematogenous Septic Arthritis in Dairy Calves.

    PubMed

    Constant, Caroline; Masseau, Isabelle; Babkine, Marie; Nichols, Sylvain; Francoz, David; Fecteau, Gilles; Marchionatti, Emma; Larde, Helene; Desrochers, Andre

    2018-06-16

     (1) To develop an evaluation grid to provide a systematic interpretation of calves' articular radiographs, (2) to describe radiographic lesions of septic arthritis in dairy calves less than 6 months of age, (3) to investigate potential associations between demographic data or synovial bacteriological culture results and radiographic lesions (4) to determine whether an association is present between radiographic lesions, their severity and the long-term outcome.  Medical records of 54 calves less than 180 days old treated for septic arthritis between 2009 and 2014 with radiographic images performed in the first 2 days after admission were reviewed.  Most common radiographic findings were increased articular joint space height ( n  = 49), irregularity of the articular surfaces ( n  = 24) and subchondral bone lysis ( n  = 24). The number of lesions observed and their severity were associated with older calves ( p  = 0.02), increased time between onset of clinical signs and admission ( p  = 0.0001) and the culture of Trueperella pyogenes within the joint ( p  = 0.02). The radiographic lesions associated with negative long-term prognosis were reduction in the joint space height ( p  = 0.01) and subchondral bone lysis on weight-bearing surfaces ( p  = 0.02).  An evaluation grid designed for veterinarians can facilitate systematic reading of articular radiographs and can be used for dairy calves with a presumptive diagnosis of septic arthritis. This diagnostic tool may aid in establishing a prognosis and decision-making process in terms of treatment. Schattauer GmbH Stuttgart.

  18. Population prevalence and distribution of ankle pain and symptomatic radiographic ankle osteoarthritis in community dwelling older adults: A systematic review and cross-sectional study

    PubMed Central

    Murray, Charlotte; Rathod, Trishna; Bowen, Catherine J.; Menz, Hylton B.; Roddy, Edward

    2018-01-01

    Objectives To identify by systematic review published prevalence estimates of radiographic ankle osteoarthritis (OA) and to subsequently estimate the prevalence of ankle pain and symptomatic, radiographic ankle OA within community-dwelling older adults from North Staffordshire, UK. Methods Electronic databases were searched using terms for ankle, osteoarthritis and radiography. Data regarding population, radiographic methods, definitions and prevalence estimates of ankle OA were extracted from papers meeting predetermined selection criteria. Adults aged ≥50 years and registered with four general practices in North Staffordshire were mailed a health questionnaire. Ankle pain in the previous month was determined using a foot and ankle pain manikin. Respondents reporting pain in or around the foot in the last 12 months were invited to attend a research clinic where weight-bearing, antero-posterior and lateral ankle radiographs were obtained and scored for OA using a standardised atlas. Prevalence estimates for ankle pain and symptomatic, radiographic ankle OA were calculated using multiple imputation and weighted logistic regression, and stratified by age, gender and socioeconomic status. Results Eighteen studies were included in the systematic review. The methods of radiographic classification of ankle OA were poorly reported and showed heterogeneity. No true general population prevalence estimates of radiographic ankle OA were found, estimates in select sporting and medical community-dwelling populations ranged from 0.0–97.1%. 5109 participants responded to the health survey questionnaire (adjusted response 56%). Radiographs were obtained in 557 participants. The prevalence of ankle pain was 11.7% (10.8,12.6) and symptomatic, radiographic ankle OA grade≥2 was 3.4% (2.3, 4.5) (grade≥1: 8.8% (7.9,9.8); grade = 3: 1.9% (1.0,2.7). Prevalence was higher in females, younger adults (50–64 years) and those with routine/manual occupations. Conclusion No general population prevalence estimates of radiographic ankle OA were identified in the published literature. Our prevalence study found that ankle pain was common in community-dwelling older adults, whereas moderate to severe symptomatic, radiographic ankle OA occurred less frequently. Further investigations of the prevalence of ankle OA using more sensitive imaging modalities are warranted. PMID:29708977

  19. Prediction of three-dimensional femoral offset from AP pelvis radiographs in primary hip osteoarthritis.

    PubMed

    Merle, C; Waldstein, W; Pegg, E C; Streit, M R; Gotterbarm, T; Aldinger, P R; Murray, D W; Gill, H S

    2013-08-01

    In pre-operative planning for total hip arthroplasty (THA), femoral offset (FO) is frequently underestimated on AP pelvis radiographs as a result of inaccurate patient positioning, imprecise magnification, and radiographic beam divergence. The aim of the present study was to evaluate the accuracy and reliability of predicting three-dimensional (3-D) FO from standardised AP pelvis radiographs. In a retrospective cohort study, pre-operative AP pelvis radiographs, AP hip radiographs and CT scans of a consecutive series of 345 patients (345 hips, 146 males, 199 females, mean age 60 (range: 40-79) years, mean body-mass-index 27 (range: 19-57)kg/m(2)) with primary end-stage hip OA were reviewed. Patients were positioned according to a standardised protocol and all images were calibrated. Using validated custom programmes, FO was measured on corresponding radiographs and CT scans. Measurement reliability was evaluated using intra-class-correlation-coefficients. To predict 3-D FO from AP pelvis measurements and to assess the accuracy compared to CT, the entire cohort was randomly split into subgroups A and B. Gender specific regression equations were derived from group A (245 patients) and the accuracy of prediction was evaluated in group B (100 patients) using Bland-Altman plots. In the entire cohort, mean FO was 39.2mm (95%CI: 38.5-40.0mm) on AP pelvis radiographs, 44.1mm (95%CI: 43.4-44.9mm) on AP hip radiographs and 44.6mm (95%CI: 44.0-45.2mm) on CT scans. In group B, we observed no significant difference between gender specific predicted FO (males: 48.0mm, 95%CI: 47.1-48.8mm; females: 42.0mm, 95%CI: 41.1-42.8mm) and FO as measured on CT (males: 47.7mm, 95%CI: 46.1-49.4mm, p=0.689; females: 41.6mm, 95%CI: 40.3-43.0mm, p=0.607). The present study suggests that FO can be accurately and reliably predicted from AP pelvis radiographs in patients with primary end-stage hip osteoarthritis. Our findings support the surgeon in pre-operative templating on AP-pelvis radiographs and may improve offset and limb length restoration in THA without the routine performance of additional radiographs or CT. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. Awareness of radiographic guidelines for low back pain: a survey of Australian chiropractors.

    PubMed

    Jenkins, Hazel J

    2016-01-01

    Chiropractors have been shown to refer for lumbar radiography in clinical scenarios inconsistent with the current clinical guidelines for low back pain. It is unknown whether this is due to lack of adherence with known guidelines or a lack of awareness of relevant guidelines. Therefore, the aim of this study is to determine Australian chiropractors' awareness of, and reported adherence to, radiographic guidelines for low back pain. Demographic, chiropractic practice and radiographic usage characteristics will be investigated for association with poor guideline adherence. An online survey was distributed to Australian chiropractors from July to September, 2014. Survey questions assessed demographic, chiropractic practice and radiographic usage characteristics, awareness of radiographic guidelines for low back pain and the level of agreement with current guidelines. Results were analysed with descriptive statistics and logistic regression analysis. There were 480 surveys completed online. Only 49.6 % (95 % confidence interval (95 % CI): 44.9, 54.4) reported awareness of radiographic guidelines for low back pain. Chiropractors reported a likelihood of referring for radiographs for low back pain: in new patients (47.6 % (95 % CI: 42.9, 52.3)); to confirm biomechanical pathologies (69.0 % (95 % CI: 64.5, 73.1)); to perform biomechanical analysis (37.5 % (95 % CI: 33.1, 42.0)); or to screen for contraindications (39.4 % (95 % CI: 35.0, 44.0)). Chiropractors agreed that radiographs for low back pain could be useful for: acute low back pain (54.0 % (95 % CI: 49.2, 58.7)); screening for contraindications (55.8 % (95 % CI: 51.0, 60.5)); or to confirm diagnosis and direct treatment (61.3 % (95 % CI: 56.5, 65.9)). Poorer adherence to current guidelines was seen if the chiropractor referred to in-house radiographic facilities, practiced a technique other than diversified technique or was unaware or unsure of current radiographic guidelines for low back pain. Only 50 % of Australian chiropractors report awareness of current radiographic guidelines for low back pain. A poorer awareness of guidelines is associated with an increase in the reported likelihood of use, and the perceived usefulness of radiographs for low back pain, in clinical situations that fall outside of current guidelines. Therefore, education strategies may help to increase guideline knowledge and compliance.

  1. Arthroplasty for cervical spondylotic myelopathy: similar results to patients with only radiculopathy at 3 years' follow-up.

    PubMed

    Fay, Li-Yu; Huang, Wen-Cheng; Wu, Jau-Ching; Chang, Hsuan-Kan; Tsai, Tzu-Yun; Ko, Chin-Chu; Tu, Tsung-Hsi; Wu, Ching-Lan; Cheng, Henrich

    2014-09-01

    Cervical arthroplasty has been accepted as a viable option for surgical management of cervical spondylosis or degenerative disc disease (DDD). The best candidates for cervical arthroplasty are young patients who have radiculopathy caused by herniated disc with competent facet joints. However, it remains uncertain whether arthroplasty is equally effective for patients who have cervical myelopathy caused by DDD. The aim of this study was to compare the outcomes of arthroplasty for patients with cervical spondylotic myelopathy (CSM) and patients with radiculopathy without CSM. A total of 151 consecutive cases involving patients with CSM or radiculopathy caused by DDD and who underwent one- or two-level cervical arthroplasty were included in this study. Clinical outcome evaluations and radiographic studies were reviewed. Clinical outcome measurements included the Visual Analog Scale (VAS) of neck and arm pain, Japanese Orthopaedic Association (JOA) scores, and the Neck Disability Index (NDI) in every patient. For patients with CSM, Nurick scores were recorded for evaluation of cervical myelopathy. Radiographic studies included lateral dynamic radiographs and CT for detection of the formation of heterotopic ossification . Of the 151 consecutive patients with cervical DDD, 125 (82.8%; 72 patients in the myelopathy group and 53 in the radiculopathy group) had at least 24 months of clinical and radiographic follow-up. The mean duration of follow-up in these patients was 36.4 months (range 24-56 months). There was no difference in sex distribution between the 2 groups. However, the mean age of the patients in the myelopathy group was approximately 6 years greater than that of the radiculopathy group (53.1 vs 47.2 years, p < 0.001). The mean operation time, mean estimated blood loss, and the percentage of patients prescribed perioperative analgesic agents were similar in both groups (p = 0.754, 0.652, and 0.113, respectively). There were significant improvements in VAS neck and arm pain, JOA scores, and NDI in both groups. Nurick scores in the myelopathy group also improved significantly after surgery. In radiographic evaluations, 92.5% of patients in the radiculopathy group and 95.8% of those in the radiculopathy group retained spinal motion (no significant difference). Evaluation of CT scans showed heterotopic ossification in 34 patients (47.2%) in the myelopathy group and 25 patients (47.1%) in the radiculopathy group (p = 0.995). At a mean of over 3 years postoperatively, no secondary surgery was reported in either group. The severity of myelopathy improves after cervical arthroplasty in patients with CSM caused by DDD. At 3-year follow-up, the clinical and radiographic outcomes of cervical arthroplasty in DDD patients with CSM are similar to those patients who have only cervical radiculopathy. Therefore, cervical arthroplasty is a viable option for patients with CSM caused by DDD who require anterior surgery. However, comparison with the standard surgical treatment of anterior cervical discectomy and fusion is necessary to corroborate the outcomes of arthroplasty for CSM.

  2. Middleware Architecture for Ambient Intelligence in the Networked Home

    NASA Astrophysics Data System (ADS)

    Georgantas, Nikolaos; Issarny, Valerie; Mokhtar, Sonia Ben; Bromberg, Yerom-David; Bianco, Sebastien; Thomson, Graham; Raverdy, Pierre-Guillaume; Urbieta, Aitor; Cardoso, Roberto Speicys

    With computing and communication capabilities now embedded in most physical objects of the surrounding environment and most users carrying wireless computing devices, the Ambient Intelligence (AmI) / pervasive computing vision [28] pioneered by Mark Weiser [32] is becoming a reality. Devices carried by nomadic users can seamlessly network with a variety of devices, both stationary and mobile, both nearby and remote, providing a wide range of functional capabilities, from base sensing and actuating to rich applications (e.g., smart spaces). This then allows the dynamic deployment of pervasive applications, which dynamically compose functional capabilities accessible in the pervasive network at the given time and place of an application request.

  3. Dental digital radiographic imaging.

    PubMed

    Mauriello, S M; Platin, E

    2001-01-01

    Radiographs are an important adjunct to providing oral health care for the total patient. Historically, radiographic images have been produced using film-based systems. However, in recent years, with the arrival of new technologies, many practitioners have begun to incorporate digital radiographic imaging into their practices. Since dental hygienists are primarily responsible for exposing and processing radiographs in the provision of dental hygiene care, it is imperative that they become knowledgeable on the use and application of digital imaging in patient care and record keeping. The purpose of this course is to provide a comprehensive overview of digital radiography in dentistry. Specific components addressed are technological features, diagnostic software, advantages and disadvantages, technique procedures, and legal implications.

  4. Radiographic findings in pulmonary hypertension from unresolved embolism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodruff, W.W. III; Hoeck, B.E.; Chitwood, W.R. Jr.

    1985-04-01

    Pulmonary artery hypertension with chronic pulmonary embolism is an uncommon entity that is potentially treatable with pulmonary embolectomy. Although the classic radiographic features have been described, several recent investigators report a significant percentage of these patients with normal chest radiographs. In a series of 22 patients, no normal radiographs were seen. Findings included cardiomegaly (86.4%) with right-sided enlargement (68.4%), right descending pulmonary artery enlargement (54.5%), azygos vein enlargement (27.3%), mosaic oligemia (68.2%), chronic volume loss (27.3%), atelectasis and/or effusion (22.7%), and pleural thickening (13.6%). Good correlation with specific areas of diminished vascularity was seen on chest radiographs compared with pulmonarymore » angiograms.« less

  5. Measuring spine fracture outcomes: common scales and checklists.

    PubMed

    Schoenfeld, Andrew J; Bono, Christopher M

    2011-03-01

    Although outcome instruments have been used extensively in spine surgical research, few studies at present specifically address their use in investigations regarding spine trauma. In this review we provide a summary of the outcome instruments used most frequently in spine trauma research, identify the unique challenges of studying outcomes of spine trauma patients, and propose an integrated approach that may be beneficial for future studies. We reviewed the use of outcome instruments applicable to spine trauma research, including generic health measures, inventories of back-specific function, pain scales, health related quality of life (HRQOL) instruments, and radiographic determinants of outcome. Several inventories have been utilised to measure clinical outcomes following spinal trauma. Excluding measures of neurological function (e.g. ASIA motor score), none have been specifically validated for use with spine fractures. The SF-36, RMDQ, and ODI are amongst the most commonly used instruments. Importantly, the use of validated functional outcome measures in spine trauma research is hampered by the fact that the pre-morbid state of patients who sustain spine trauma may not be accurately represented by normative values established for the general population. The VAS is used most frequently to assess degree of neck and back pain. Most studies have relied on non-validated measures to determine radiographic results of treatment, although more elegant radiographic metrics exist. Functional outcome measurement of traumatically injured spine patients is challenging because available generic and spine-specific instruments were not designed for or validated in this population. Furthermore, no single inventory is capable of capturing global data necessary to evaluate results following these injuries. Investigations seeking to quantify outcomes following spine trauma should consider the use of a combination of existing surveys in a complementary fashion that should include a generic health survey, a measure of back-specific function, and determinants of bodily pain and work-related disability. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Applications of nuclear techniques relevant for civil security

    NASA Astrophysics Data System (ADS)

    Valkovi, Vlado

    2006-05-01

    The list of materials which are subject to inspection with the aim of reducing the acts of terrorism includes explosives, narcotics, chemical weapons, hazardous chemicals and radioactive materials. To this we should add also illicit trafficking with human beings. The risk of nuclear terrorism carried out by sub-national groups is considered not only in construction and/or use of nuclear device, but also in possible radioactive contamination of large urban areas. Modern personnel, parcel, vehicle and cargo inspection systems are non-invasive imaging techniques based on the use of nuclear analytical techniques. The inspection systems use penetrating radiations: hard x-rays (300 keV or more) or gamma-rays from radioactive sources (137Cs and 60Co with energies from 600 to 1300 keV) that produce a high resolution radiograph of the load. Unfortunately, this information is ''non-specific'' in that it gives no information on the nature of objects that do not match the travel documents and are not recognized by a visual analysis of the radiographic picture. Moreover, there are regions of the container where x and gamma-ray systems are ''blind'' due to the high average atomic number of the objects irradiated that appear as black spots in the radiographic image. Contrary to that is the use of neutrons; as results of the bombardment, nuclear reactions occur and a variety of nuclear particles, gamma and x-ray radiation is emitted, specific for each element in the bombarded material. The problem of material (explosive, drugs, chemicals, etc.) identification can be reduced to the problem of measuring elemental concentrations. Neutron scanning technology offers capabilities far beyond those of conventional inspection systems. The unique automatic, material specific detection of terrorist threats can significantly increase the security at ports, border-crossing stations, airports, and even within the domestic transportation infrastructure of potential urban targets as well as protecting armed forces and infrastructure.

  7. Radiologic Career Ladder, AFSC 903X0.

    DTIC Science & Technology

    1985-07-01

    SACROILIAC (S-I) JOINTS 87 36 TABLE 10 TOP TASKS FOR 90350 PERSONNEL (PERCENT MEMBERS PERFORMING) PERCENT MEMBERS TASKS PERFORMING M445 LOAD OR UNLOAD...RADIOGRAPHIC EXAMINATIONS OF THE SACROILIAC (S-I) JOINTS 81 G204 PERFORM RADIOGRAPHIC EXAMINATIONS OF THE SACRUM 81 37 en %00 -T in Q C h0 n P. - wlw -% %0... SACROILIAC (S-I) JOINTS 97 0227 SHIELD PATIENTS DURING RADIOGRAPHIC EXAMINATIONS 96 0175 PERFORM RADIOGRAPHIC EXAMINATIONS OF THE ACROKIO CLAVICULAR (A-C

  8. Mastodon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coleman, Justin Leigh; Veeraraghavan, Swetha; Bolisetti, Chandrakanth

    MASTODON has the capability to model stochastic nonlinear soil-structure interaction (NLSSI) in a dynamic probabilistic risk assessment framework. The NLSSI simulations include structural dynamics, time integration, dynamic porous media flow, nonlinear hysteretic soil constitutive models, geometric nonlinearities (gapping, sliding, and uplift). MASTODON is also the MOOSE based master application for dynamic PRA of external hazards.

  9. Implant treatment planning regarding augmentation procedures: panoramic radiographs vs. cone beam computed tomography images.

    PubMed

    Dagassan-Berndt, Dorothea C; Zitzmann, Nicola U; Walter, Clemens; Schulze, Ralf K W

    2016-08-01

    To evaluate the impact of cone beam computed tomography (CBCT) imaging on treatment planning regarding augmentation procedures for implant placement. Panoramic radiographs and CBCT images of 40 patients requesting single-tooth implants in 59 sites were retrospectively analyzed by six specialists in implantology, and treatment planning was performed. Therapeutic recommendations were compared with the surgical protocol performed initially. Bone height estimation from panoramic radiographs yielded to higher measures and greater variability compared to CBCT. The suggested treatment plan for lateral and vertical augmentation procedures based on CBCT or panoramic radiographs coincided for 55-72% of the cases. A trend to a more invasive augmentation procedure was seen when planning was based on CBCT. Panoramic radiography revealed 57-63% (lateral) vs. 67% (vertical augmentation) congruent plans in agreement with surgery. Among the dissenting sites, there was a trend toward less invasive planning for lateral augmentation with panoramic radiographs, while vertical augmentation requirements were more frequently more invasive when based on CBCT. Vertical augmentation requirements can be adequately determined from panoramic radiographs. In difficult cases with a deficient lateral alveolar bone, the augmentation schedule may better be evaluated from CBCT to avoid underestimation, which occurs more frequently when based on panoramic radiographs only. However, overall, radiographic interpretation and diagnostic thinking accuracy seem to be mainly depending on the opinion of observers. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Bone and cartilage characteristics in postmenopausal women with mild knee radiographic osteoarthritis and those without radiographic osteoarthritis

    PubMed Central

    Multanen, J.; Heinonen, A.; Häkkinen, A.; Kautiainen, H.; Kujala, U.M.; Lammentausta, E.; Jämsä, T.; Kiviranta, I.; Nieminen, M.T.

    2015-01-01

    Objectives: To evaluate the association between radiographically-assessed knee osteoarthritis and femoral neck bone characteristics in women with mild knee radiographic osteoarthritis and those without radiographic osteoarthritis. Methods: Ninety postmenopausal women (mean age [SD], 58 [4] years; height, 163 [6] cm; weight, 71 [11] kg) participated in this cross-sectional study. The severity of radiographic knee osteoarthritis was defined using Kellgren-Lawrence grades 0=normal (n=12), 1=doubtful (n=25) or 2=minimal (n=53). Femoral neck bone mineral content (BMC), section modulus (Z), and cross-sectional area (CSA) were measured with DXA. The biochemical composition of ipsilateral knee cartilage was estimated using quantitative MRI measures, T2 mapping and dGEMRIC. The associations between radiographic knee osteoarthritis grades and bone and cartilage characteristics were analyzed using generalized linear models. Results: Age-, height-, and weight-adjusted femoral neck BMC (p for linearity=0.019), Z (p for linearity=0.033), and CSA (p for linearity=0.019) increased significantly with higher knee osteoarthritis grades. There was no linear relationship between osteoarthritis grades and knee cartilage indices. Conclusions: Increased DXA assessed hip bone strength is related to knee osteoarthritis severity. These results are hypothesis driven that there is an inverse relationship between osteoarthritis and osteoporosis. However, MRI assessed measures of cartilage do not discriminate mild radiographic osteoarthritis severity. PMID:25730654

  11. Fluoroscopic and radiographic evaluation of tracheal collapse in dogs: 62 cases (2001-2006).

    PubMed

    Macready, Dawn M; Johnson, Lynelle R; Pollard, Rachel E

    2007-06-15

    To compare the use of radiography and fluoroscopy for detection and grading of tracheal collapse in dogs. Retrospective case series. Animals-62 dogs with tracheal collapse. For each dog, tracheal collapse was confirmed fluoroscopically and lateral cervical and thoracic radiographic views were reviewed. A board-certified radiologist (who was unaware of the dogs' clinical history) evaluated the cervical, thoracic inlet, thoracic, carinal, and main stem bronchial regions in all fluoroscopic videos and radiographic images for evidence of collapse. Cervical, thoracic inlet, thoracic, and carinal regions in both radio-graphic and fluoroscopic studies were graded for collapse (0%, 25%, 50%, 75%, or 100% decrease in diameter). Lateral cervical and thoracic radiographic images were available for 54 dogs, and inspiratory and expiratory lateral cervical and thoracic radiographic images were available for 8 dogs. For detection of tracheal collapse, assessment of radiographic views was sensitive and had the best negative predictive value in the cervical and thoracic inlet regions. Assessment of radiographic views was most specific and had the best positive predictive value in the thoracic inlet, thoracic, carina, and main stem bronchial regions. Radiography underestimated the degree of collapse in all areas. Review of inspiratory and expiratory views improved the accuracy of radiography for tracheal collapse diagnosis only slightly. Compared with fluoroscopy, radiography underestimated the frequency and degree of tracheal collapse. However, radiography appears to be useful for screening dogs with potential tracheal collapse.

  12. Application of lead-acrylic compensating filters in chiropractic full spine radiography: a technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buehler, M.T.; Hrejsa, A.F.

    X-raying the entire spinal column in the standing position in a single exposure (mainly the AP projection) is an often-used chiropractic radiography procedure which has also found some application in medical scoliosis screening program. Aside from any controversy of clinical objectives or medical necessity, the primary agreed-upon requisite for such procedure is twofold; achieving the best possible film image quality with the least amount of radiation exposure to the patient. A popular method of accomplishing this objective is by the use of collimator-attached devices designed to selectively filter the primary x-ray beam in accordance with regional variations of body thicknessmore » and/or density. This study was conducted to evaluate the use of a new lead-acrylic filter system under specialized chiropractic conditions. In comparison to other available systems, it was concluded that this new system; a) is generally equivalent in its radiation dose reduction capabilities; b) is capable of producing full spine radiographs with good to above average image quality; and c) is appreciably easier to use.« less

  13. New heights in ultrasound: first report of spinal ultrasound from the international space station.

    PubMed

    Marshburn, Thomas H; Hadfield, Chris A; Sargsyan, Ashot E; Garcia, Kathleen; Ebert, Douglas; Dulchavsky, Scott A

    2014-01-01

    Changes in the lumbar and sacral spine occur with exposure to microgravity in astronauts; monitoring these alterations without radiographic capabilities on the International Space Station (ISS) requires novel diagnostic solutions to be developed. We evaluated the ability of point-of-care ultrasound, performed by nonexpert-operator astronauts, to provide accurate anatomic information about the spine in long-duration crewmembers in space. Astronauts received brief ultrasound instruction on the ground and performed in-flight cervical and lumbosacral ultrasound examinations using just-in-time training and remote expert tele-ultrasound guidance. Ultrasound examinations on the ISS used a portable ultrasound device with real-time communication/guidance with ground experts in Mission Control. The crewmembers were able to obtain diagnostic-quality examinations of the cervical and lumbar spine that would provide essential information about acute or chronic changes to the spine. Spinal ultrasound provides essential anatomic information in the cervical and lumbosacral spine; this technique may be extensible to point-of-care situations in emergency departments or resource-challenged areas without direct access to additional radiologic capabilities. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Unstable 3D phenomena: Dynamic interactions of a cavitation bubble and Richtmyer-Meshkov unstable divot

    NASA Astrophysics Data System (ADS)

    Buttler, William; Renner, Dru; Morris, Chris; Manzanares, Ruben; Heidemann, Joel; Kalas, Ryan; Llobet, Anna; Martinez, John; Payton, Jeremy; Saunders, Andy; Schmidt, Derek; Tainter, Amy; Vincent, Samuel; Vogan-McNeil, Wendy

    2017-06-01

    We radiographically explore a shock-induced Sn cavitation bubble as it interacts with a transverse cavitation wave caused by a Richtmyer-Meshkov unstable spike from a divot. The cavitation bubble forms as two shockwaves collide under the divot, as the shockwaves release to ambient pressure at the surface. The divot inverts and unstably grows, as expected and predicted, but the release waves that form the cavitation bubble reflect from and constrain the cavitation wave growth. As the cavitation wave grows it pierces the cavitation bubble, deflating it onto the unstable transverse cavitation wave.

  15. Internal sub-sonic burning during an explosion viewed via dynamic X-ray radiography

    NASA Astrophysics Data System (ADS)

    Smilowitz, L.; Henson, B. F.; Oschwald, D.; Suvorova, N.; Remelius, D.

    2017-10-01

    We observe internal convective and conductive burn front propagation and solid consumption subsequent to thermal ignition for plastic bonded formulations of the solid organic secondary explosives octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine and 1,3,5-triamino-2,4,6-trinitrobenzene. This work describes x-ray radiographic diagnostics enabling the study of solid density in a fully encased explosive during internal burning subsequent to ignition. The result of this study is the ability to directly observe and measure rates of energy release during a thermal explosion.

  16. BBU design of linear induction accelerator cells for radiography application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shang, C.C.; Chen, Y.J.; Gaporaso, G.J.

    1997-05-06

    There is an ongoing effort to develop accelerating modules for high-current electron accelerators for advanced radiography application. Accelerating modules with low beam-cavity coupling impedances along with gap designs with acceptable field stresses comprise a set of fundamental design criteria. We examine improved cell designs which have been developed for accelerator application in several radiographic operating regimes. We evaluate interaction impedances, analyze the effects of beam structure coupling on beam dynamics (beam break-up instability and corkscrew motion). We also provide estimates of coupling through interesting new high-gradient insulators and evaluate their potential future application in induction cells.

  17. 10 CFR 34.41 - Conducting industrial radiographic operations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Conducting industrial radiographic operations. 34.41 Section 34.41 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.41...

  18. 10 CFR 34.41 - Conducting industrial radiographic operations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Conducting industrial radiographic operations. 34.41 Section 34.41 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.41...

  19. 10 CFR 34.41 - Conducting industrial radiographic operations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Conducting industrial radiographic operations. 34.41 Section 34.41 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.41...

  20. 10 CFR 34.41 - Conducting industrial radiographic operations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Conducting industrial radiographic operations. 34.41 Section 34.41 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.41...

  1. 10 CFR 34.41 - Conducting industrial radiographic operations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Conducting industrial radiographic operations. 34.41 Section 34.41 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.41...

  2. Perform - A performance optimizing computer program for dynamic systems subject to transient loadings

    NASA Technical Reports Server (NTRS)

    Pilkey, W. D.; Wang, B. P.; Yoo, Y.; Clark, B.

    1973-01-01

    A description and applications of a computer capability for determining the ultimate optimal behavior of a dynamically loaded structural-mechanical system are presented. This capability provides characteristics of the theoretically best, or limiting, design concept according to response criteria dictated by design requirements. Equations of motion of the system in first or second order form include incompletely specified elements whose characteristics are determined in the optimization of one or more performance indices subject to the response criteria in the form of constraints. The system is subject to deterministic transient inputs, and the computer capability is designed to operate with a large linear programming on-the-shelf software package which performs the desired optimization. The report contains user-oriented program documentation in engineering, problem-oriented form. Applications cover a wide variety of dynamics problems including those associated with such diverse configurations as a missile-silo system, impacting freight cars, and an aircraft ride control system.

  3. Potential utilization of the NASA/George C. Marshall Space Flight Center in earthquake engineering research

    NASA Technical Reports Server (NTRS)

    Scholl, R. E. (Editor)

    1979-01-01

    Earthquake engineering research capabilities of the National Aeronautics and Space Administration (NASA) facilities at George C. Marshall Space Flight Center (MSFC), Alabama, were evaluated. The results indicate that the NASA/MSFC facilities and supporting capabilities offer unique opportunities for conducting earthquake engineering research. Specific features that are particularly attractive for large scale static and dynamic testing of natural and man-made structures include the following: large physical dimensions of buildings and test bays; high loading capacity; wide range and large number of test equipment and instrumentation devices; multichannel data acquisition and processing systems; technical expertise for conducting large-scale static and dynamic testing; sophisticated techniques for systems dynamics analysis, simulation, and control; and capability for managing large-size and technologically complex programs. Potential uses of the facilities for near and long term test programs to supplement current earthquake research activities are suggested.

  4. Back-propagation learning of infinite-dimensional dynamical systems.

    PubMed

    Tokuda, Isao; Tokunaga, Ryuji; Aihara, Kazuyuki

    2003-10-01

    This paper presents numerical studies of applying back-propagation learning to a delayed recurrent neural network (DRNN). The DRNN is a continuous-time recurrent neural network having time delayed feedbacks and the back-propagation learning is to teach spatio-temporal dynamics to the DRNN. Since the time-delays make the dynamics of the DRNN infinite-dimensional, the learning algorithm and the learning capability of the DRNN are different from those of the ordinary recurrent neural network (ORNN) having no time-delays. First, two types of learning algorithms are developed for a class of DRNNs. Then, using chaotic signals generated from the Mackey-Glass equation and the Rössler equations, learning capability of the DRNN is examined. Comparing the learning algorithms, learning capability, and robustness against noise of the DRNN with those of the ORNN and time delay neural network, advantages as well as disadvantages of the DRNN are investigated.

  5. Simulation results of corkscrew motion in DARHT-II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, K. D.; Ekdahl, C. A.; Chen, Y. J.

    2003-01-01

    DARHT-II, the second axis of the Dual-Axis Radiographic Hydrodynamics Test Facility, is being commissioned. DARHT-II is a linear induction accelerator producing 2-microsecond electron beam pulses at 20 MeV and 2 kA. These 2-microsecond pulses will be chopped into four short pulses to produce time resolved x-ray images. Radiographic application requires the DARHT-II beam to have excellent beam quality, and it is important to study various beam effects that may cause quality degradation of a DARHT-II beam. One of the beam dynamic effects under study is 'corkscrew' motion. For corkscrew motion, the beam centroid is deflected off axis due to misalignmentsmore » of the solenoid magnets. The deflection depends on the beam energy variation, which is expected to vary by {+-}0.5% during the 'flat-top' part of a beam pulse. Such chromatic aberration will result in broadening of beam spot size. In this paper, we will report simulation results of our study of corkscrew motion in DARHT-II. Sensitivities of beam spot size to various accelerator parameters and the strategy for minimizing corkscrew motion will be described. Measured magnet misalignment is used in the simulation.« less

  6. A broadband proton backlighting platform to probe shock propagation in low-density systems

    DOE PAGES

    Sio, H.; Hua, R.; Ping, Y.; ...

    2017-01-17

    A proton backlighting platform has been developed for the study of strong shock propagation in low-density systems in planar geometry. Electric fields at the converging shock front in inertial confinement fusion implosions have been previously observed, demonstrating the presence of—and the need to understand—strong electric fields not modeled in standard radiation-hydrodynamic simulations. In this planar configuration, long-pulse ultraviolet lasers are used to drive a strong shock into a gas-cell target, while a short-pulse proton backlighter side-on radiographs the shock propagation. Finally, the capabilities of the platform are presented here. Future experiments will vary shock strength and gas fill, to probemore » shock conditions at different Z and T e.« less

  7. Positron radiography of ignition-relevant ICF capsules

    NASA Astrophysics Data System (ADS)

    Williams, G. J.; Chen, Hui; Field, J. E.; Landen, O. L.; Strozzi, D. J.

    2017-12-01

    Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 × 1012 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2 g/cm2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. We evaluate the effects of magnetic fields near the capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.

  8. Practice patterns in spine radiograph utilization among doctors of chiropractic enrolled in a provider network offering complementary care in the United States.

    PubMed

    Bussières, André E; Sales, Anne E; Ramsay, Timothy; Hilles, Steven; Grimshaw, Jeremy M

    2013-01-01

    Nonspecific back pain is associated with high use of diagnostic imaging in primary care, yet current evidence suggests that routine imaging of the spine is unnecessary. The objective of this study is to describe current practice patterns in spine radiograph utilization among doctors of chiropractic enrolled in an American provider network. A cross-sectional analysis of administrative claims data from one of the largest providers of complementary health care networks for health plans in the United States was performed. Survey data containing provider demographics were linked with routinely collected data on spine radiograph utilization and patient characteristics aggregated at the provider level. We calculated rates and variations of spine radiographs over 12 months. Negative binomial regression was performed to identify significant predictors of high radiograph utilization and to estimate the associated incidence risk ratio. Complete data for 6946 doctors of chiropractic and 249193 adult patients were available for analyses. In 2010, claims were paid for a total of 91542 new patient examinations and 23369 spine radiographs (including 17511 ordered within 5 days of initial patient examination). The rate of spine radiographs within 5 days of an initial patient visit was 204 per 1000 new patient examinations. Significant predictors of higher radiograph utilization rates included the following: practicing in the Midwest or South US census regions, practicing in an urban or suburban setting, chiropractic school attended, and being a male provider in full-time practice with more than 20 years of experience. Chiropractic school attended and practice location were the most influential predictors of spine radiograph utilization among network chiropractors. This information may help to inform the development and evaluation of a tailored intervention to address overuse of radiograph utilization. Copyright © 2013 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  9. Radiographic abnormalities and the risk of lung cancer among workers exposed to silica dust in Ontario.

    PubMed Central

    Finkelstein, M M

    1995-01-01

    OBJECTIVE: To determine whether workers in Ontario who had been exposed to silica dust and who have radiographic abnormalities are at increased risk of lung cancer. DESIGN: Cohort and case-control studies of rates of death from lung cancer and cancer incidence rates; data were obtained from the Ontario Silicosis Surveillance Registry. Follow-up was through linkage to the Ontario mortality and cancer registries. SETTING: Ontario. PARTICIPANTS: A total of 523 workers with radiographic abnormalities and 1568 control subjects with normal radiographic findings who had been exposed to silica dust. Matching criteria were year of birth and the requirement that the control subject have a normal radiographic finding either later than or in the same year that the radiographic abnormality was identified in the silicosis subject. OUTCOME MEASURES: Standardized mortality ratios (SMRs), standardized incidence ratios (SIRs) and odds ratios for lung cancer. RESULTS: In the cohort analysis, with the Ontario population rates as reference, the all-cause SMR was 0.96 among the workers with radiographic abnormalities and 0.51 among the control subjects. The corresponding SIRs for lung cancer were 2.49 and 0.87 (p < 0.001). In the case-control analysis the workers with silicosis were more likely than the control subjects to have been smokers, but this difference likely accounted for only a small part of the difference in the incidence of lung cancer. The relative risk of lung cancer was elevated among the workers with silicosis from the foundry, mining and nonmetallic-minerals industries; however, the number of subjects was too small for a significant difference to be detected. Among the miners exposure to radon daughters did not affect the risk of lung cancer attributable to radiographic abnormalities. CONCLUSIONS: Radiographic abnormalities suggestive of exposure to silica dust are markers for increased risk of lung cancer. Physicians might thus wish to warn their patients with silica-associated radiographic abnormalities about the increased risk and to counsel those who smoke to stop. PMID:7804920

  10. Radiographic Severity of Rheumatoid Arthritis in African-Americans: Results from the CLEAR Registry

    PubMed Central

    Bridges, S. Louis; Causey, Zenoria L.; Burgos, Paula I.; Huynh, B. Quynh N.; Hughes, Laura B.; Danila, Maria I.; van Everdingen, Amalia; Ledbetter, Stephanie; Conn, Doyt L.; Tamhane, Ashutosh; Westfall, Andrew O.; Jonas, Beth L.; Callahan, Leigh F.; Smith, Edwin A.; Brasington, Richard; Moreland, Larry W.; Alarcón, Graciela S.; van der Heijde, Désirée M.

    2010-01-01

    Objective To describe radiographic changes in African-Americans with rheumatoid arthritis (RA) from the CLEAR (Consortium for the Longitudinal Evaluation of African-Americans with Early Rheumatoid Arthritis) Registry, a multicenter observational study. Methods Self-declared African-American patients, were enrolled in CLEAR I, a longitudinal cohort of early RA (disease duration <2 years) from 2000 to 2005; or in CLEAR II, a cross-sectional cohort (any disease duration), from 2006 to the present. Demographic and clinical data were obtained, and sets of hand/wrist and foot radiographs were scored using the modified Sharp/van der Heijde scoring system. Results A total of 357 and 418 patients, respectively, have been enrolled into CLEAR I and CLEAR II. We report here an interim analysis of radiographic severity in these patients. For the CLEAR I cohort, 294 patients had a mean radiographic score of 2.89 at the baseline visit; 32.0% showed either erosions (25.9%) or joint space narrowing (JSN) (19.4%). At the 36-month visit the mean score was 5.65; 44.2% had erosions, 41.5% JSN and 55.4% had either. Among those patients without radiographic damage at baseline, 18.9% had progressed at the 36-month visit, compared to 57.1% of those with baseline damage (p<0.0001). For the CLEAR II cohort, 167 patients with RA of any duration, 65.3% exhibited joint erosions, 65.3% JSN and 74.8% exhibited either. The mean radiographic score was 33.42. Conclusion This is the largest radiographic study of African American RA patients. Damage occurs early in the disease and is associated with radiographic progression at 3 years of disease duration. The CLEAR Registry will provide a valuable resource for future analyses of genetic, clinical, and environmental factors associated with radiographic severity of RA in African-Americans. PMID:20461784

  11. Frequency of abnormal hand and wrist radiographs at time of diagnosis of polyarticular juvenile rheumatoid arthritis.

    PubMed

    Mason, Tom; Reed, Ann M; Nelson, Audrey M; Thomas, Kristen B; Patton, Alice; Hoffman, Alan D; Achenbach, Sara; O'Fallon, William M

    2002-10-01

    To determine the frequency of radiographic abnormalities in hand/wrist radiographs of children with newly diagnosed polyarticular juvenile rheumatoid arthritis (polyJRA) because radiographs of small joints are an important tool in assessing outcomes in RA and there are clinical similarities between RA and polyJRA. A medical record review was performed to identify cases of polyJRA seen at Mayo Clinic from January 1, 1994, to December 31, 2001. Hand/wrist radiographs, obtained at the time of diagnosis, were reviewed by 3 radiologists with attention to periarticular osteopenia, joint space narrowing (JSN), or erosion. At least 2 radiologists had to independently identify abnormal findings on the same radiograph. The relative carpal length (RCL), judged by Poznanski's method, was also determined. From the review of 159 medical records, 60 cases of newly diagnosed polyJRA were identified. Twenty-five of these had hand/wrist radiographs at diagnosis; 18 sets were available for this study. Of those, 2/3 were female, 6% (1/18) had subcutaneous nodules, 7% (1/14) had elevated levels of serum rheumatoid factor, and 44% (7/16) had elevated serum levels of antinuclear antibodies. Median age at diagnosis was 10.2 years, median duration of hand/wrist symptoms at diagnosis was 10 months, and median number of joints with either swelling, pain on range of motion (ROM), or limited ROM was 14.5. Sixty-one percent of radiographs taken at the time of diagnosis of polyJRA were abnormal. While 44% had periarticular osteopenia, 28% had either erosions or JSN. Six (33%) had RCL > 2 SD below the mean for age. Five (83%) of those with RCL, > 2 SD below the mean for age, had periarticular osteopenia, JSN, or erosion. We conclude the frequency of abnormal hand/wrist radiographs is very high very early in the course of polyJRA. More studies are needed to determine to what extent these radiographic abnormalities correlate with clinical outcomes.

  12. Generalized bone loss as a predictor of three-year radiographic damage in African American patients with recent-onset rheumatoid arthritis.

    PubMed

    Zhang, Jie; Redden, David T; McGwin, Gerald; Callahan, Leigh F; Smith, Edwin A; Alarcón, Graciela S; Moreland, Larry W; van der Heijde, Désirée M; Brown, Elizabeth E; Arnett, Donna K; Mikuls, Ted R; Bridges, S Louis

    2010-08-01

    To examine the association between baseline bone mineral density (BMD) and radiographic damage at 3 years of disease duration in a longitudinal cohort of African Americans with recent-onset rheumatoid arthritis (RA). African American RA patients with a disease duration of <2 years (n = 141) were included in the study. All patients underwent baseline BMD measurements (femoral neck and/or lumbar spine) using dual x-ray absorptiometry. T scores were calculated using normative data from the general population of African Americans. Patients were categorized as having osteopenia/osteoporosis (T score less than or equal to -1) or as being healthy. Hand and wrist radiographs, obtained at baseline and at 3 years of disease duration, were scored using the modified Sharp/van der Heijde method. The association between baseline BMD and total radiographic score at 3 years of disease was examined using multivariable negative binomial regression. At baseline, the mean age and the mean disease duration were 52.4 years and 14.8 months, respectively; 85.1% of the patients were women. The average total radiographic scores at baseline and at 3 years of disease were 2.4 and 5.7, respectively. In the final reduced multivariable model, adjusting for age, sex, anti-cyclic citrullinated peptide antibody positivity, and the presence of radiographic damage at baseline, the total radiographic score at 3 years disease in patients with osteopenia/osteoporosis of the femoral neck was twice that in patients with normal bone density, and the difference was statistically significant (P = 0.0084). No association between lumbar spine osteopenia/osteoporosis and radiographic score was found. Our findings suggest that reduced generalized BMD may be a predictor of future radiographic damage and support the hypothesis that radiographic damage and reduced generalized BMD in RA patients may share a common pathogenic mechanism.

  13. Quality assurance in digital dental radiography--justification and dose reduction in dental and maxillofacial radiology.

    PubMed

    Hellstern, F; Geibel, M-A

    2012-01-01

    To evaluate the implementation of quality assurance requirements for digital dental radiography in routine clinical practice. The results should be discussed by radiation protection authorities in the context of the relevant legal requirements and current debates on radiation protection. Two hundred digital dental radiographs were randomly selected from the digital database of the Department of Dentistry's Dental and Maxillofacial Surgery Clinic, Ulm University, and evaluated for various aspects of image quality and compliance with radiographic documentation requirements. The dental films were prepared by different radiology assistants (RAs) using one of two digital intraoral radiographic systems: Sirona Heliodent DS, 60 kV, focal spot size: 0.7 mm (group A) or KaVo Gendex 765 DC, 65 kV, focal spot size: 0.4 mm (group B). Radiographic justification was documented in 70.5% of cases, and the radiographic findings in 76.5%. Both variables were documented in the patient records as well as in the software in 14% of cases. Clinical documentation of the required information (name of the responsible dentist and radiology assistant, date, patient name, department, tube voltage, tube current, exposure time, type of radiograph, film size, department and serial number of the dental radiograph) was 100% complete in all cases. Moreover, the department certified according to DIN ISO 9001:2008 specifications demonstrated complete clinical documentation of radiographic justifications and radiographic findings. The entire dentition was visible on 83% of the digital films. The visible area corresponded to the target region on 85.7% of the digital dental radiographs. Seven to 8.5% of the images were classified as "hypometric" or "hypermetric". This study indicates that improvements in radiology training and continuing education fordentists and dental staff performing x-ray examinations are needed to ensure consistent high quality of digital dental radiography. Implementation of internal radiological quality assurance programs, as required by public law in Germany since 2010 (SGB V), would appear prudent.

  14. Normal variation in sagittal spinal alignment parameters in adult patients: an EOS study using serial imaging.

    PubMed

    Hey, Hwee Weng Dennis; Tan, Kian Loong Melvin; Moorthy, Vikaesh; Lau, Eugene Tze-Chun; Lau, Leok-Lim; Liu, Gabriel; Wong, Hee-Kit

    2018-03-01

    To describe normal variations in sagittal spinal radiographic parameters over an interval period and establish physiological norms and guidelines for which these images should be interpreted. Data were prospectively collected from a continuous series of adult patients with first-episode mild low back pain presenting to a single institution. The sagittal parameters of two serial radiographic images taken 6-months apart were obtained with the EOS ® slot scanner. Measured parameters include CL, TK, TL, LL, PI, PT, SS, and end and apical vertebrae. Chi-squared test and Wilcoxon Signed Rank test were used to compare categorical and continuous variables, respectively. Sixty patients with a total of 120 whole-body sagittal X-rays were analysed. Mean age was 52.1 years (SD 21.2). Mean interval between the first and second X-rays was 126.2 days (SD 47.2). Small variations (< 1°) occur for all except PT (1.2°), CL (1.2°), and SVA (2.9 cm). Pelvic tilt showed significant difference between two images (p = 0.035). Subgroup analysis based on the time interval between X-rays, and between the first and second X-rays, did not show significant differences. Consistent findings were found for end and apical vertebrae of the thoracic and lumbar spine between the first and second X-rays for sagittal curve shapes. Radiographic sagittal parameters vary between serial images and reflect dynamism in spinal balancing. SVA and PT are predisposed to the widest variation. SVA has the largest variation between individuals of low pelvic tilt. Therefore, interpretation of these parameters should be patient specific and relies on trends rather than a one-time assessment.

  15. Understanding External Cervical Resorption in Vital Teeth.

    PubMed

    Mavridou, Athina M; Hauben, Esther; Wevers, Martine; Schepers, Evert; Bergmans, Lars; Lambrechts, Paul

    2016-12-01

    The aim of this study was to investigate the 3-dimensional (3D) structure and the cellular and tissue characteristics of external cervical resorption (ECR) in vital teeth and to understand the phenomenon of ECR by combining histomorphological and radiographic findings. Twenty-seven cases of vital permanent teeth displaying ECR were investigated. ECR diagnosis was based on clinical and radiographic examination with cone-beam computed tomographic imaging. The extracted teeth were further analyzed by using nanofocus computed tomographic imaging, hard tissue histology, and scanning electron microscopy. All examined teeth showed some common characteristics. Based on the clinical and experimental findings, a 3-stage mechanism of ECR was proposed. At the first stage (ie, the initiation stage), ECR was initiated at the cementum below the gingival epithelial attachment. At the second stage (ie, the resorption stage), the resorption invaded the tooth structure 3-dimensionally toward the pulp space. However, it did not penetrate the pulp space because of the presence of a pericanalar resorption-resistant sheet. This layer was observed to consist of predentin, dentin, and occasionally reparative mineralized (bonelike) tissue, having a fluctuating thickness averaging 210 μm. At the last advanced stage (ie, the repair stage), repair took place by an ingrowth and apposition of bonelike tissue into the resorption cavity. During the reparative stage, repair and remodeling phenomena evolve simultaneously, whereas both resorption and reparative stages progress in parallel at different areas of the tooth. ECR is a dynamic and complex condition that involves periodontal and endodontic tissues. Using clinical, histologic, radiographic, and scanning microscopic analysis, a better understanding of the evolution of ECR is possible. Based on the experimental findings, a 3-stage mechanism for the initiation and growth of ECR is proposed. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. The floating cardiac fat pad-sign of occult pneumothorax.

    PubMed

    Kaufman, Claire; Bokhari, S A Jamal

    2016-08-01

    Pneumothoraces are a possible sequela of chest trauma with potential morbidity and mortality if not recognized and treated promptly. A portable supine chest radiograph is frequently the first radiologic study performed in the setting of trauma. While large pneumothoraces can be readily recognized on these radiographs, smaller pneumothoraces are missed in up to 15 % of trauma patients. There are many radiographic signs of occult pneumothoraces, and we are presenting a new radiographic sign of occult pneumothorax. The floating cardiac fat pad sign occurs when pleural air collects anteriorly and superiorly in the most non-dependent portion of the chest lifting the pericardial fat pad off the diaphragm. Lung markings are still seen surrounding the pericardial fat pad due to the inflated lower lobe of the lung resting dependently. Rapid and accurate identification of pneumothoraces is critical but often difficult on chest radiographs. Although there are many existing radiographic signs for identification of pneumothorax, prospective identification of small pneumothoraces is still relatively poor. Here, we describe an additional sign which aides in the detection of pneumothoraces, the floating cardiac fat pad. When present, this should prompt further evaluation with chest CT or upright chest radiograph.

  17. Effect of two X-ray tube voltages on detection of approximal caries in digital radiographs. An in vitro study.

    PubMed

    Hellén-Halme, Kristina

    2011-04-01

    This study evaluated the effect of two different tube voltages on clinicians' ability to diagnose approximal carious lesions in digital radiographs. One hundred extracted teeth were radiographed twice at two voltage settings, 60 and 70 kV, using a standardized procedure. Seven observers evaluated the radiographs on a standard color monitor pre-calibrated according to DICOM part 14. Evaluations were made at ambient light levels below 50 lx. All observations were analyzed with receiver operating characteristic curves. A histological examination of the teeth served as the criterion standard. A paired t test compared the effects of the two voltages. The significance level was set to p < 0.05. Weighted kappa statistics estimated intra-observer agreement. No significant difference in accuracy of approximal carious lesion diagnosis was found between the two voltage settings. But five observers rated dentin lesions on radiographs exposed at 70 kV better than on radiographs exposed at 60 kV. Intra-observer agreement differed from fair to moderate. There was no significant difference in accuracy of approximal carious lesion diagnosis between digital radiographs exposed with 60 or 70 kV.

  18. Evaluation of trabecular bone patterns on dental radiographic images: influence of cortical bone

    NASA Astrophysics Data System (ADS)

    Amouriq, Yves; Evenou, Pierre; Arlicot, Aurore; Normand, Nicolas; Layrolle, Pierre; Weiss, Pierre; Guédon, Jean-Pierre

    2010-03-01

    For some authors trabecular bone is highly visible in intraoral radiographs. For other authors, the observed intrabony trabecular pattern is a representation of only the endosteal surface of cortical bone, not of intermedullary striae. The purpose of this preliminary study was to investigate the true anatomical structures that are visible in routine dental radiographs and classically denoted trabecular bone. This is a major point for bone texture analysis on radiographs. Computed radiography (CR) images of dog mandible section in molar region were compared with simulations calculated from high-resolution micro-CT volumes. Calculated simulations were obtained using the Mojette Transform. By digitally editing the CT volume, the simulations were separated into trabecular and cortical components into a region of interest. Different images were compared and correlated, some bone micro-architecture parameters calculated. A high correlation was found between computed radiographs and calculated simulations from micro-CT. The Mojette transform was successful to obtain high quality images. Cortical bone did not contribute to change in a major way simulated images. These first results imply that intrabony trabecular pattern observed on radiographs can not only be a representation of the cortical bone endosteal surface and that trabecular bone is highly visible in intraoral radiographs.

  19. Bayesian latent class estimation of the incidence of chest radiograph-confirmed pneumonia in rural Thailand.

    PubMed

    Lu, Y; Baggett, H C; Rhodes, J; Thamthitiwat, S; Joseph, L; Gregory, C J

    2016-10-01

    Pneumonia is a leading cause of mortality and morbidity worldwide with radiographically confirmed pneumonia a key disease burden indicator. This is usually determined by a radiology panel which is assumed to be the best available standard; however, this assumption may introduce bias into pneumonia incidence estimates. To improve estimates of radiographic pneumonia incidence, we applied Bayesian latent class modelling (BLCM) to a large database of hospitalized patients with acute lower respiratory tract illness in Sa Kaeo and Nakhon Phanom provinces, Thailand from 2005 to 2010 with chest radiographs read by both a radiology panel and a clinician. We compared these estimates to those from conventional analysis. For children aged <5 years, estimated radiographically confirmed pneumonia incidence by BLCM was 2394/100 000 person-years (95% credible interval 2185-2574) vs. 1736/100 000 person-years (95% confidence interval 1706-1766) from conventional analysis. For persons aged ⩾5 years, estimated radiographically confirmed pneumonia incidence was similar between BLCM and conventional analysis (235 vs. 215/100 000 person-years). BLCM suggests the incidence of radiographically confirmed pneumonia in young children is substantially larger than estimated from the conventional approach using radiology panels as the reference standard.

  20. Ultrasonographic and radiographic findings in 503 cattle with traumatic reticuloperitonitis.

    PubMed

    Braun, Ueli; Gerspach, Christian; Warislohner, Sonja; Nuss, Karl; Ohlerth, Stefanie

    2018-05-26

    This study involved 503 cattle with traumatic reticuloperitonitis (TRP), 494 of which underwent ultrasonographic and 484 radiographic examination of the reticulum. Ultrasonography revealed changes in the reticulum and/or peritoneum suggestive of peritonitis in 403 (83%) cattle, a decrease in the amplitude of reticular contractions in 244 (54%) and reduced or absent reticular motility in 173 (37%). A total of 536 foreign bodies were seen on 465 (96%) radiographs and a magnet was seen on 311 (64%) radiographs. Of the 536 foreign bodies, 300 (56%) were not attached to a magnet and 236 (44%) were attached. Of 300 radiographs showing foreign bodies not attached to a magnet, the foreign body was lying flat on the floor of the reticulum on 98 (18%) radiographs, was at an angle of greater than 30 degrees to the ventral aspect of the reticulum on 54 (10%), had penetrated the dorsal reticular wall on 76 (14%), had perforated the reticulum on 64 (12%) and was completely outside of the reticulum on 8 (1%) radiographs. Ultrasonography provides information about the scale and localisation of inflammatory changes of the peritoneum, and radiography allows the visualisation of ferromagnetic foreign bodies and magnets. Copyright © 2018. Published by Elsevier Ltd.

  1. An artifacts removal post-processing for epiphyseal region-of-interest (EROI) localization in automated bone age assessment (BAA)

    PubMed Central

    2011-01-01

    Background Segmentation is the most crucial part in the computer-aided bone age assessment. A well-known type of segmentation performed in the system is adaptive segmentation. While providing better result than global thresholding method, the adaptive segmentation produces a lot of unwanted noise that could affect the latter process of epiphysis extraction. Methods A proposed method with anisotropic diffusion as pre-processing and a novel Bounded Area Elimination (BAE) post-processing algorithm to improve the algorithm of ossification site localization technique are designed with the intent of improving the adaptive segmentation result and the region-of interest (ROI) localization accuracy. Results The results are then evaluated by quantitative analysis and qualitative analysis using texture feature evaluation. The result indicates that the image homogeneity after anisotropic diffusion has improved averagely on each age group for 17.59%. Results of experiments showed that the smoothness has been improved averagely 35% after BAE algorithm and the improvement of ROI localization has improved for averagely 8.19%. The MSSIM has improved averagely 10.49% after performing the BAE algorithm on the adaptive segmented hand radiograph. Conclusions The result indicated that hand radiographs which have undergone anisotropic diffusion have greatly reduced the noise in the segmented image and the result as well indicated that the BAE algorithm proposed is capable of removing the artifacts generated in adaptive segmentation. PMID:21952080

  2. Filmless versus film-based systems in radiographic examination costs: an activity-based costing method.

    PubMed

    Muto, Hiroshi; Tani, Yuji; Suzuki, Shigemasa; Yokooka, Yuki; Abe, Tamotsu; Sase, Yuji; Terashita, Takayoshi; Ogasawara, Katsuhiko

    2011-09-30

    Since the shift from a radiographic film-based system to that of a filmless system, the change in radiographic examination costs and costs structure have been undetermined. The activity-based costing (ABC) method measures the cost and performance of activities, resources, and cost objects. The purpose of this study is to identify the cost structure of a radiographic examination comparing a filmless system to that of a film-based system using the ABC method. We calculated the costs of radiographic examinations for both a filmless and a film-based system, and assessed the costs or cost components by simulating radiographic examinations in a health clinic. The cost objects of the radiographic examinations included lumbar (six views), knee (three views), wrist (two views), and other. Indirect costs were allocated to cost objects using the ABC method. The costs of a radiographic examination using a filmless system are as follows: lumbar 2,085 yen; knee 1,599 yen; wrist 1,165 yen; and other 1,641 yen. The costs for a film-based system are: lumbar 3,407 yen; knee 2,257 yen; wrist 1,602 yen; and other 2,521 yen. The primary activities were "calling patient," "explanation of scan," "take photographs," and "aftercare" for both filmless and film-based systems. The cost of these activities cost represented 36.0% of the total cost for a filmless system and 23.6% of a film-based system. The costs of radiographic examinations using a filmless system and a film-based system were calculated using the ABC method. Our results provide clear evidence that the filmless system is more effective than the film-based system in providing greater value services directly to patients.

  3. Follow-up imaging of the urinary tract in spinal injury patients: is a KUB necessary with every ultrasound?

    PubMed

    Tins, B; Teo, H-G; Popuri, R; Cassar-Pullicino, V; Tyrrell, P

    2005-04-01

    Prospective study of 100 consecutive patients. To evaluate the diagnostic usefulness of the urinary tract (KUB) radiograph routinely performed as part of spinal injury patient urinary tract screening with ultrasound (US) and the KUB radiograph. Orthopaedic and District General Hospital with spinal injuries unit, UK. Prospective study of the urinary tract of 100 consecutive routine follow-up spinal injury patients with KUB (kidneys, ureters, bladder) radiograph and US of the urinary tract. The percentage of the visualised area of kidneys and urinary bladder and relevant abnormal findings were recorded. Relevant patient history was recorded. In all, 80 men 20 women were examined (average age 46 years, average time since injury 11 years). A total of 199 kidneys and 99 urinary bladders were examined. On average, less than 50% of the renal area and about 70-75% of the urinary bladder area were visualised. Five patients had renal stones identified on the KUB radiograph, and of these two were seen on US. There were no stones seen on US only. The patient history was not helpful to identify patients with renal stones. Significant further renal abnormalities were identified with US in 14 patients, and with the KUB radiograph in 0 patients. Significant urinary bladder abnormalities were identified with US in 20 patients, and with the KUB radiograph in 0 patients. On average, less than 50% of the kidney area is visualised on the KUB due to overlying bowel markings making the KUB radiograph a poor tool to assess the kidneys. The KUB radiograph and US are poor tools to assess urinary tract stones. In the absence of a therapeutic consequence, the KUB radiograph does not seem justified in the routine follow-up of the urinary tract in spinal injury patients.

  4. Filmless versus film-based systems in radiographic examination costs: an activity-based costing method

    PubMed Central

    2011-01-01

    Background Since the shift from a radiographic film-based system to that of a filmless system, the change in radiographic examination costs and costs structure have been undetermined. The activity-based costing (ABC) method measures the cost and performance of activities, resources, and cost objects. The purpose of this study is to identify the cost structure of a radiographic examination comparing a filmless system to that of a film-based system using the ABC method. Methods We calculated the costs of radiographic examinations for both a filmless and a film-based system, and assessed the costs or cost components by simulating radiographic examinations in a health clinic. The cost objects of the radiographic examinations included lumbar (six views), knee (three views), wrist (two views), and other. Indirect costs were allocated to cost objects using the ABC method. Results The costs of a radiographic examination using a filmless system are as follows: lumbar 2,085 yen; knee 1,599 yen; wrist 1,165 yen; and other 1,641 yen. The costs for a film-based system are: lumbar 3,407 yen; knee 2,257 yen; wrist 1,602 yen; and other 2,521 yen. The primary activities were "calling patient," "explanation of scan," "take photographs," and "aftercare" for both filmless and film-based systems. The cost of these activities cost represented 36.0% of the total cost for a filmless system and 23.6% of a film-based system. Conclusions The costs of radiographic examinations using a filmless system and a film-based system were calculated using the ABC method. Our results provide clear evidence that the filmless system is more effective than the film-based system in providing greater value services directly to patients. PMID:21961846

  5. Demographic and clinical factors associated with radiographic severity of first metatarsophalangeal joint osteoarthritis: cross-sectional findings from the Clinical Assessment Study of the Foot.

    PubMed

    Menz, H B; Roddy, E; Marshall, M; Thomas, M J; Rathod, T; Myers, H; Thomas, E; Peat, G M

    2015-01-01

    To explore demographic and clinical factors associated with radiographic severity of first metatarsophalangeal joint osteoarthritis (OA) (First MTPJ OA). Adults aged ≥50 years registered with four general practices were mailed a Health Survey. Responders reporting foot pain within the last 12 months were invited to undergo a clinical assessment and weight-bearing dorso-plantar and lateral radiographs of both feet. Radiographic first MTPJ OA in the most severely affected foot was graded into four categories using a validated atlas. Differences in selected demographic and clinical factors were explored across the four radiographic severity subgroups using analysis of variance (ANOVA) and ordinal regression. Clinical and radiographic data were available from 517 participants, categorised as having no (n = 105), mild (n = 228), moderate (n = 122) or severe (n = 62) first MTPJ OA. Increased radiographic severity was associated with older age and lower educational attainment. After adjusting for age, increased radiographic first MTPJ OA severity was significantly associated with an increased prevalence of dorsal hallux and first MTPJ pain, hallux valgus, first interphalangeal joint (IPJ) hyperextension, keratotic lesions on the dorsal aspect of the hallux and first MTPJ, decreased first MTPJ dorsiflexion, ankle/subtalar joint eversion and ankle joint dorsiflexion range of motion, and a trend towards a more pronated foot posture. This cross-sectional study has identified several dose-response associations between radiographic severity of first MTPJ OA and a range of demographic and clinical factors. These findings highlight the progressive nature of first MTPJ OA and provide insights into the spectrum of presentation of the condition in clinical practice. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  6. Association and comparison between visual inspection and bitewing radiography for the detection of recurrent dental caries under restorations.

    PubMed

    Lino, José R; Ramos-Jorge, Joana; Coelho, Valéria Silveira; Ramos-Jorge, Maria L; Moysés, Marcos R; Ribeiro, José C R

    2015-08-01

    The aim of the present study was to investigate, in posterior teeth, the association between the characteristics of the margins of a restoration visually inspected and the presence, under restorations, of recurrent or residual dental caries detected by radiographic examination. Furthermore, the agreement between visual inspection and radiographs to detect dental caries was assessed. Eighty-five permanent molars and premolars with resin restorations on the interproximal and/or occlusal faces, from 18 patients, were submitted for visual inspection and radiographic examination. The visual inspection involved the criteria of the International Caries Detection and Assessment System (ICDAS). Bitewing radiographs were used for the radiographic examination. Logistic regression was used to analyse the association between the characteristics of the margins of a restoration assessed by visual inspection (absence of dental caries, or early, established, inactive and active lesions) and the presence of recurrent caries detected by radiographs. Kappa coefficients were calculated for determining agreement between the two methods. The Kappa coefficient for agreement between visual inspection and radiographic examination was 0.19. Established lesions [odds ratio (OR) = 9.89; 95% confidence interval (95% CI): 2.94-33.25; P < 0.05] and lesion activity (OR = 2.57; 95% CI: 0.91-7.27; P < 0.05) detected by visual inspection, were associated with recurrent or residual dental caries detected by radiographs. Restorations with established and active lesions at the margins had a greater chance of exhibiting recurrent or residual lesions in the radiographic examination. The present findings demonstrate that restorations with established and active lesions at the margins when visually inspected often require removal and retreatment. © 2015 FDI World Dental Federation.

  7. Are We Using Abdominal Radiographs Appropriately in the Management of Pediatric Constipation?

    PubMed

    Beinvogl, Beate; Sabharwal, Sabina; McSweeney, Maireade; Nurko, Samuel

    2017-12-01

    To identify the reasons why pediatric gastroenterologists obtain abdominal radiographs in the management of pediatric constipation. This was a prospective study surveying providers regarding their rationale, interpretation, resultant change, and confidence in their management before and after obtaining KUBs in patients seen for suspected constipation. Demographics and clinical findings were obtained from medical records. A total of 24 providers were surveyed after 72 patient encounters. Reasons for obtaining an abdominal radiograph included evaluation of stool burden (70%), need for a clean out (35%), fecal impaction (27%), cause of abdominal pain (24%), demonstration of stool burden to families (14%), assessment of response to therapy (13%), or encopresis (10%). The plan was changed in 47.6% of cases based on radiographic findings. In cases in which a plan was outlined before obtaining the radiograph (69%), the initial plan was implemented on average in 52.5%. In cases with no plans before obtaining the radiograph, previously unconsidered plans were implemented in 8.7%. Provider confidence in the management plan increased from 2.4 ± 2.7 to 4.1 ± 1.8 (P < .05) after the abdominal radiograph. Abdominal radiographs commonly are obtained by pediatric gastroenterologists in the evaluation and management of constipation. The majority used it to make a diagnosis, and nearly one-half changed their management based on the imaging findings. Overall, they reported an improved confidence in their management plan, despite evidence that radiographic findings poorly correlate with clinical severity. This study highlights the need for further provider education regarding the recommendations delineated in existing constipation guidelines. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Effectiveness Of Plain Shoulder Radiograph In Detecting Degenerate Rotator Cuff Tears.

    PubMed

    Hussain, Adnan; Muzzammil, Muhammad; Butt, Faisal; Valsamis, Epaminondas Markos; Dwyer, Amitabh J

    2018-01-01

    Studies have demonstrated radiographic findings of sclerosis and cortical irregularity at the greater tuberosity can suggest a rotator cuff tear. Plain radiographs are the most easily attainable first-line investigations in evaluating shoulder injuries. This study determines the effectiveness in predicting degenerate rotator cuff tears by detecting radiographic changes on shoulder x-rays. Retrospective cross-sectional study with a consecutive series of patients conducted in Hinchingbrooke Hospital, Huntingdon, United Kingdom from January 2015 to June 2017. Anteroposterior shoulder radiographs of 150 symptomatic patients who underwent shoulder arthroscopy were independently analysed by surgeons who were blinded from the arthroscopic results. Patients aged fewer than 30 and over 70 years were excluded. Patients with advanced osteoarthritis and cuff tear arthropathy evident on x-rays were also excluded. Sixty-five patients included in the study had rotator cuff tears on arthroscopy. Radiographic changes were correlated with arthroscopic findings to determine this test's ability to predict degenerate rotator cuff tears. When both cortical irregularity and sclerosis were present on the plain radiograph, these signs had a sensitivity of 78.8% [95% CI 65.7, 87.8%] and specificity 77.4% [95% CI 67.2, 85.0%] with a positive predictive value of 68.3%, using contingency table analysis. The presence of cortical irregularity was found to be a better predictor of a tear as compared to sclerosis. This study concludes that plain radiograph are good modality for initial evaluation of rotator cuff tears and detecting when both cortical irregularity and sclerosis. Consideration of these radiographic findings serves as a useful adjunct in diagnostic workup and can guide subsequent investigations and treatment when evaluating rotator cuff tears of the shoulder.

  9. Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography.

    PubMed

    Dietrich, Tobias J; Pfirrmann, Christian W A; Schwab, Alexander; Pankalla, Katja; Buck, Florian M

    2013-07-01

    To compare the radiation dose, workflow, patient comfort, and financial break-even of a standard digital radiography and a biplanar low-dose X-ray system. A standard digital radiography system (Ysio, Siemens Healthcare, Erlangen, Germany) was compared with a biplanar X-ray unit (EOS, EOS imaging, Paris, France) consisting of two X-ray tubes and slot-scanning detectors, arranged at an angle of 90° allowing simultaneous vertical biplanar linear scanning in the upright patient position. We compared data of standing full-length lower limb radiographs and whole spine radiographs of both X-ray systems. Dose-area product was significantly lower for radiographs of the biplanar X-ray system than for the standard digital radiography system (e.g. whole spine radiographs; standard digital radiography system: 392.2 ± 231.7 cGy*cm(2) versus biplanar X-ray system: 158.4 ± 103.8 cGy*cm(2)). The mean examination time was significantly shorter for biplanar radiographs compared with standard digital radiographs (e.g. whole spine radiographs: 449 s vs 248 s). Patients' comfort regarding noise was significantly higher for the standard digital radiography system. The financial break-even point was 2,602 radiographs/year for the standard digital radiography system compared with 4,077 radiographs/year for the biplanar X-ray unit. The biplanar X-ray unit reduces radiation exposure and increases subjective noise exposure to patients. The biplanar X-ray unit demands a higher number of examinations per year for the financial break-even point, despite the lower labour cost per examination due to the shorter examination time.

  10. A study to determine the added value of 740 screening panoramic radiographs compared to intraoral radiography in the management of adult (>18 years) dentate patients in a primary care setting.

    PubMed

    Rushton, Michael N; Rushton, Vivian E

    2012-08-01

    To measure the added value of panoramic radiography in new dentate patients attending for routine treatment. Thirty-seven general dental practitioners using panoramic radiographs routinely were recruited. Twenty dentate patients were identified prospectively by each participating dentist if they were new to the practice, attending for an examination and requesting any treatment deemed necessary. A panoramic radiograph was taken with appropriate intraoral radiographs in line with national guidelines. Each dentist completed a radiological report for the panoramic radiograph only and these 20 reports were forwarded to the researchers along with the 20 panoramic radiographs, their accompanying bitewing and periapical radiographs and twenty completed clinical assessment sheets. 740 panoramic, 1418 bitewing and 325 periapical radiographs were assessed by the researchers. Only 32 panoramic films provided any additional diagnostic value when compared to intraoral films when guidelines had been observed resulting from the poor technical and processing quality of the accompanying intraoral films. Assessment of the number of caries and periapical lesions and the degree of periodontal bone loss from the intraoral films provided a greater diagnostic yield at the p<0.001 level of significance. The research found that dentists underestimated the number of caries lesions present and level of periodontal bone loss when compared to the researchers but overestimated the presence of periapical pathology, at the level of significance at p<0.001. The study found that there was no support for the use of panoramic radiographs in routine screening as there was no net diagnostic benefit to the patient. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Effect of cumulative exposure to corticosteroid and DMARD on radiographic progression in rheumatoid arthritis: results from the ESPOIR cohort.

    PubMed

    Louveau, Baptiste; De Rycke, Yann; Lafourcade, Alexandre; Saraux, Alain; Guillemin, Francis; Tubach, Florence; Fautrel, Bruno; Hajage, David

    2018-05-22

    Several authors have tried to predict the risk of radiographic progression in RA according to baseline characteristics, considering exposure to treatment only as a binary variable (Treated: Yes/No). This study aims to model the risk of 5-year radiographic progression taking into account both baseline characteristics and the cumulative time-varying exposure to corticosteroids or DMARDs. The study population consisted of 403 patients of the Etude et Suivi des Polyarthrites Indifférenciées Récentes cohort meeting the 1987 ACR or 2010 ACR/EULAR criteria for RA at inclusion and having complete radiographic data at baseline and 5 years. Radiographic progression was defined at 5 years as a significant increase of the Sharp/van der Heidje score (smallest detectable difference ⩾5). The best logistic regression model was selected from the following: model including only clinico-biological baseline characteristics; model considering baseline characteristics and treatments as binary variables; and model considering baseline characteristics and treatments as weighted cumulative exposure variables. Radiographic progression occurred in 143 (35.5%) patients. The best model combined anti-citrullinated peptide antibody positivity, ESR, swollen joint count >14 and erosion score at baseline, as well as corticosteroids, MTX/LEF (MTX or LEF) and biologic DMARDs (bDMARDs) as weighted cumulative exposure variables. Recent cumulative exposure to high doses of corticosteroids (⩽ 3months) was significantly associated with the risk of 5-year radiographic progression and a significant protective association was highlighted for a 36-month exposure to bDMARDs. Corticosteroids and bDMARDs play an important role in radiographic progression. Accounting for treatment class and intensity of exposure is a major concern in predictive models of radiographic progression in RA patients.

  12. Radiographers' areas of professional competence related to good nursing care.

    PubMed

    Andersson, Bodil T; Fridlund, Bengt; Elgán, Carina; Axelsson, Asa B

    2008-09-01

    Radiographers' ability and competence is a matter of vital importance for patients. Nursing care is an integral part of the radiographer's work. The demand for high competence in clinical activities has increased in diagnostic radiology and has had an impact on the development of the profession. The aim was to describe the radiographer's areas of professional competence in relation to good nursing care based on critical incidents that occur in the course of radiological examinations and interventions. A descriptive design with a qualitative approach, using the Critical Incident Technique was employed. Interviews were conducted with a strategic sample of registered radiographers (n = 14), based at different hospitals in Sweden. The appropriate ethical principles were followed. All the participants provided informed consent, and formal approval for conducting the research was obtained according to national and local directives. The data analysis resulted in two main areas; direct and indirect patient-related areas of competence, which describe the radiographers' skills that either facilitate or hinder good nursing care. In the direct patient-related area of competence, four categories emerged, which illustrate good nursing care in the patient's immediate surroundings. In the indirect patient-related area of competence, four categories illuminated good nursing care that is provided without direct contact with the patient. The study highlights the different areas of the radiographer's unique professional competence. The findings provide insight into the radiographer's profession, on one hand as a carer and on the other as a medical technologist as well as highlighting the importance of each role. The radiographer's work encompasses a variety of components--from caring for the patient to handling and checking the technical equipment.

  13. Association between -174G/C and -572G/C interleukin 6 gene polymorphisms and severe radiographic damage to the hands of Mexican patients with rheumatoid arthritis: a preliminary report.

    PubMed

    Zavaleta-Muñiz, S A; Gonzalez-Lopez, L; Murillo-Vazquez, J D; Saldaña-Cruz, A M; Vazquez-Villegas, M L; Martín-Márquez, B T; Vasquez-Jimenez, J C; Sandoval-Garcia, F; Ruiz-Padilla, A J; Fajardo-Robledo, N S; Ponce-Guarneros, J M; Rocha-Muñoz, A D; Alcaraz-Lopez, M F; Cardona-Müller, D; Totsuka-Sutto, S E; Rubio-Arellano, E D; Gamez-Nava, J I

    2016-12-19

    Several interleukin 6 gene (IL6) polymorphisms are implicated in susceptibility to rheumatoid arthritis (RA). It has not yet been established with certainty if these polymorphisms are associated with the severe radiographic damage observed in some RA patients, particularly those with the development of joint bone ankylosis (JBA). The objective of the present study was to evaluate the association between severe radiographic damage in hands and the -174G/C and -572G/C IL6 polymorphisms in Mexican Mestizo people with RA. Mestizo adults with RA and long disease duration (>5 years) were classified into two groups according to the radiographic damage in their hands: a) severe radiographic damage (JBA and/or joint bone subluxations) and b) mild or moderate radiographic damage. We compared the differences in genotype and allele frequencies of -174G/C and -572G/C IL6 polymorphisms (genotyped using polymerase chain reaction-restriction fragment length polymorphism) between these two groups. Our findings indicated that the -174G/C polymorphism of IL6 is associated with severe joint radiographic damage [maximum likelihood odds ratios (MLE_OR): 8.03; 95%CI 1.22-187.06; P = 0.03], whereas the -572G/C polymorphism of IL6 exhibited no such association (MLE_OR: 1.5; 95%CI 0.52-4.5; P = 0.44). Higher anti-cyclic citrullinated peptide antibody levels were associated with more severe joint radiographic damage (P = 0.04). We conclude that there is a relevant association between the -174G/C IL6 polymorphism and severe radiographic damage. Future studies in other populations are required to confirm our findings.

  14. A multicenter study analyzing the relationship of a standardized radiographic scoring system of adolescent idiopathic scoliosis and the Scoliosis Research Society outcomes instrument.

    PubMed

    Wilson, Philip L; Newton, Peter O; Wenger, Dennis R; Haher, Thomas; Merola, Andrew; Lenke, Larry; Lowe, Thomas; Clements, David; Betz, Randy

    2002-09-15

    A multicenter study examining the association between radiographic and outcomes measures in adolescent idiopathic scoliosis. To evaluate the association between an objective radiographic scoring system and patient quality of life measures as determined by the Scoliosis Research Society outcomes instrument. Although surgical correction of scoliosis has been reported to be positively correlated with patient outcomes, studies to date have been unable to demonstrate an association between radiographic measures of deformity and outcomes measures in patients with adolescent idiopathic scoliosis. A standardized radiographic deformity scoring system and the Scoliosis Research Society outcome tool were used prospectively in seven scoliosis centers to collect data on patients with adolescent idiopathic scoliosis. A total of 354 data points for 265 patients consisting of those with nonoperative or preoperative curves >or=10 degrees, as well as those with surgically treated curves, were analyzed. Correlation analysis was performed to identify significant relationships between any of the radiographic measures, the Harms Study Group radiographic deformity scores (total, sagittal, coronal), and the seven Scoliosis Research Society outcome domains (Total Pain, General Self-Image, General Function, Activity, Postoperative Self-Image, Postoperative Function, and Satisfaction) as well as Scoliosis Research Society outcomes instrument total scores. Radiographic measures that were identified as significantly correlated with Scoliosis Research Society outcome scores were then entered into a stepwise regression analysis. The coronal measures of thoracic curve and lumbar curve magnitude were found to be significantly correlated with the Total Pain, General Self-Image, and total Scoliosis Research Society scores (P < 0.0001). The thoracic and upper thoracic curve magnitudes were also correlated with General Function (P < 0.002). The "coronal" subscore as well as the "total" score of the Harms Study Group radiographic scoring system were also significantly correlated with these Scoliosis Research Society domain and total scores. No radiographic measures taken after surgery were significantly correlated with the postoperative domains of the Scoliosis Research Society outcomes instrument. Stepwise regression analysis of these radiographic measures as predictors of Scoliosis Research Society scores resulted in adjusted R2 values of 0.03-0.07 (P < 0.0001). Although these results show that a significant association exists between the radiographic Cobb angle measure of the scoliosis and the Scoliosis Research Society outcomes scores, the low R2 values indicate that variables other than the radiographic appearance of the deformity (e.g., psychosocial, functional) must also be affecting these scores. The Cobb angle measure of the major deformity has a small, but statistically significant, correlation with the reported Total Pain, General Self-Image, and General Function as measured by the Scoliosis Research Society outcomes instrument. None of the radiographic measures in this population correlated with postoperative domain scores of the Scoliosis Research Society outcomes tool.

  15. A new technique for radiographic measurement of acetabular cup orientation.

    PubMed

    Derbyshire, Brian; Diggle, Peter J; Ingham, Christopher J; Macnair, Rory; Wimhurst, James; Jones, Henry Wynn

    2014-02-01

    Accurate radiographic measurement of acetabular cup orientation is required in order to assess susceptibility to impingement, dislocation, and edge loading wear. In this study, the accuracy and precision of a new radiographic cup orientation measurement system were assessed and compared to those of two commercially available systems. Two types of resurfacing hip prostheses and an uncemented prosthesis were assessed. Radiographic images of each prosthesis were created with the cup set at different, known angles of version and inclination in a measurement jig. The new system was the most accurate and precise and could repeatedly measure version and inclination to within a fraction of a degree. In addition it has a facility to distinguish cup retroversion from anteversion on anteroposterior radiographs. © 2013.

  16. 10 CFR Appendix A to Part 34 - Radiographer Certification

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Pt. 34, App. A Appendix A to Part 34—Radiographer Certification I... of industrial radiography; 2. Make its membership available to the general public nationwide that is...

  17. 10 CFR Appendix A to Part 34 - Radiographer Certification

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Pt. 34, App. A Appendix A to Part 34—Radiographer Certification I... of industrial radiography; 2. Make its membership available to the general public nationwide that is...

  18. 10 CFR Appendix A to Part 34 - Radiographer Certification

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Pt. 34, App. A Appendix A to Part 34—Radiographer Certification I... of industrial radiography; 2. Make its membership available to the general public nationwide that is...

  19. 10 CFR Appendix A to Part 34 - Radiographer Certification

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Pt. 34, App. A Appendix A to Part 34—Radiographer Certification I... of industrial radiography; 2. Make its membership available to the general public nationwide that is...

  20. Two new methods to increase the contrast of track-etch neutron radiographs

    NASA Technical Reports Server (NTRS)

    Morley, J.

    1973-01-01

    In one method, fluorescent dye is deposited into tracks of radiograph and viewed under ultraviolet light. In second method, track-etch radiograph is placed between crossed polaroid filters, exposed to diffused light and resulting image is projected onto photographic film.

  1. 21 CFR 892.1960 - Radiographic intensifying screen.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic intensifying screen. 892.1960 Section 892.1960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1960 Radiographic intensifying screen...

  2. 21 CFR 892.1910 - Radiographic grid.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic grid. 892.1910 Section 892.1910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1910 Radiographic grid. (a) Identification. A...

  3. Pulmonary fibrosis in asbestos insulation workers with lung cancer: a radiological and histopathological evaluation.

    PubMed Central

    Kipen, H M; Lilis, R; Suzuki, Y; Valciukas, J A; Selikoff, I J

    1987-01-01

    This study was undertaken to determine the relation between radiographic and histological manifestations of pulmonary asbestosis (interstitial fibrosis) in insulation workers who had died of lung cancer. Of 450 confirmed deaths from lung cancer a chest radiograph suitable for determining evidence of pneumoconiosis was obtained in 219. Of these cases, 138 also had a tissue specimen submitted that was suitable for histological study to determine the extent of histological fibrosis. There was a significant albeit limited correlation between the radiographic and histological findings (r = 0.27, p less than 0.0013). All 138 cases had histological evidence of parenchymal fibrosis; in 25 (18%), however, there was no radiographic evidence of parenchymal fibrosis. In 10 cases (7%) both parenchymal and pleural disease were undetectable on the radiograph. Thus a negative chest radiograph does not exclude the presence of interstitial fibrosis (asbestosis) in a substantial proportion of insulation workers previously exposed to asbestos who develop lung cancer. PMID:3814551

  4. Weld radiograph enigmas

    NASA Technical Reports Server (NTRS)

    Jemian, Wartan A.

    1986-01-01

    Weld radiograph enigmas are features observed on X-ray radiographs of welds. Some of these features resemble indications of weld defects, although their origin is different. Since they are not understood, they are a source of concern. There is a need to identify their causes and especially to measure their effect on weld mechanical properties. A method is proposed whereby the enigmas can be evaluated and rated, in relation to the full spectrum of weld radiograph indications. Thie method involves a signature and a magnitude that can be used as a quantitive parameter. The signature is generated as the diference between the microdensitometer trace across the radiograph and the computed film intensity derived from a thickness scan along the corresponding region of the sample. The magnitude is the measured difference in intensity between the peak and base line values of the signature. The procedure is demonstated by comparing traces across radiographs of a weld sample before and after the introduction of a hole and by a system based on a MacIntosh mouse used for surface profiling.

  5. Plain abdominal radiographs in acute medical emergencies: an abused investigation?

    PubMed

    Feyler, S; Williamson, V; King, D

    2002-02-01

    Plain abdominal radiographs are commonly requested for acute medical emergencies on patients with non-specific abdominal symptoms and signs. In this study 131 plain abdominal radiographs performed on the day of admission were prospectively analysed. In only 16 cases (12%) the reasons for requests conformed to the recommended guidelines by the Royal College of Radiologists. The reason for the request was stated in the case notes in only three cases. In 62 cases (47%), there was no comment made on the film by the requesting clinician. There was a discrepancy in the interpretation of the radiograph between the clinician and the radiologist in 31 cases (24%). The clinical management was influenced by plain abdominal radiographs in only nine cases (7%). The majority of plain abdominal radiographs requested on acute medical emergencies is inappropriate. There is a need to ensure guidelines are followed to prevent unnecessary exposure of patients to radiation as well as preventing expenditure on irrelevant investigations.

  6. Plain abdominal radiographs in acute medical emergencies: an abused investigation?

    PubMed Central

    Feyler, S; Williamson, V; King, D

    2002-01-01

    Plain abdominal radiographs are commonly requested for acute medical emergencies on patients with non-specific abdominal symptoms and signs. In this study 131 plain abdominal radiographs performed on the day of admission were prospectively analysed. In only 16 cases (12%) the reasons for requests conformed to the recommended guidelines by the Royal College of Radiologists. The reason for the request was stated in the case notes in only three cases. In 62 cases (47%), there was no comment made on the film by the requesting clinician. There was a discrepancy in the interpretation of the radiograph between the clinician and the radiologist in 31 cases (24%). The clinical management was influenced by plain abdominal radiographs in only nine cases (7%). The majority of plain abdominal radiographs requested on acute medical emergencies is inappropriate. There is a need to ensure guidelines are followed to prevent unnecessary exposure of patients to radiation as well as preventing expenditure on irrelevant investigations. PMID:11807192

  7. Development of a detector model for generation of synthetic radiographs of cargo containers

    NASA Astrophysics Data System (ADS)

    White, Timothy A.; Bredt, Ofelia P.; Schweppe, John E.; Runkle, Robert C.

    2008-05-01

    Creation of synthetic cargo-container radiographs that possess attributes of their empirical counterparts requires accurate models of the imaging-system response. Synthetic radiographs serve as surrogate data in studies aimed at determining system effectiveness for detecting target objects when it is impractical to collect a large set of empirical radiographs. In the case where a detailed understanding of the detector system is available, an accurate detector model can be derived from first-principles. In the absence of this detail, it is necessary to derive empirical models of the imaging-system response from radiographs of well-characterized objects. Such a case is the topic of this work, where we demonstrate the development of an empirical model of a gamma-ray radiography system with the intent of creating a detector-response model that translates uncollided photon transport calculations into realistic synthetic radiographs. The detector-response model is calibrated to field measurements of well-characterized objects thus incorporating properties such as system sensitivity, spatial resolution, contrast and noise.

  8. Comparison of Lumbar Lordosis in Lateral Radiographs in Standing Position with supine MR Imaging in consideration of the Sacral Slope.

    PubMed

    Benditz, Achim; Boluki, Daniel; Weber, Markus; Zeman, Florian; Grifka, Joachim; Völlner, Florian

    2017-03-01

    Purpose  To investigate the influence of sacral slope on the correlation between measurements of lumbar lordosis obtained by standing radiographs and magnetic resonance images in supine position (MRI). Little information is available on the correlation between measurements of lumbar lordosis obtained by radiographic and MR images. Most relevant studies have shown correlations for the thoracic spine, but detailed analyses on the lumbar spine are lacking. Methods  MR images and standing lateral radiographs of 63 patients without actual low back pain or radiographic pathologies of the lumbar spine were analyzed. Standing radiographic measurements included the sagittal parameters pelvic incidence (PI) pelvic tilt (PT), and sacral slope (SS); MR images were used to additionally measure lumbar L1-S1 lordosis and single level lordosis. Differences between radiographic and MRI measurements were analyzed and divided into 4 subgroups of different sacral slope according to Roussouly's classification. Results  Global lumbar lordosis (L1-S1) was 44.99° (± 10 754) on radiographs and 47.91° (± 9.170) on MRI, yielding a clinically relevant correlation (r = 0.61, p < 0.01). Measurements of single level lordosis only showed minor differences. At all levels except for L5 / S1, lordosis measured by means of standing radiographs was higher than that measured by MRI. The difference in global lumbar L1-S1 lordosis was -2.9°. Analysis of the Roussouly groups showed the largest difference for L1-S1 (-8.3°) in group 2. In group 4, when measured on MRI, L5 / S1 lordosis (25.71°) was lower than L4 / L5 lordosis (27.63°) compared to the other groups. Conclusions  Although measurements of global lumbar lordosis significantly differed between the two scanning technologies, the mean difference was just 2.9°. MRI in supine position may be used for estimating global lumbar lordosis, but single level lordosis should be determined by means of standing radiographs. Key Points   · Large difference between radiographic and MRI measurements of level L5 / S1.. · MRI can be used for estimating global lumbar lordosis.. · Analysis of single level lordosis necessitates measurement in standing radiographs.. Citation Format · Benditz A, Boluki D, Weber M et al. Comparison of Lumbar Lordosis in Lateral Radiographs in Standing Position with supine MR Imaging in consideration of the Sacral Slope. Fortschr Röntgenstr 2017; 189: 233 - 239. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Aircraft Landing Dynamics Facility - A unique facility with new capabilities

    NASA Technical Reports Server (NTRS)

    Davis, P. A.; Stubbs, S. M.; Tanner, J. A.

    1985-01-01

    The Aircraft Landing Dynamics Facility (ALDF), formerly called the Landing Loads Track, is described. The paper gives a historical overview of the original NASA Langley Research Center Landing Loads Track and discusses the unique features of this national test facility. Comparisons are made between the original track characteristics and the new capabilities of the Aircraft Landing Dynamics Facility following the recently completed facility update. Details of the new propulsion and arresting gear systems are presented along with the novel features of the new high-speed carriage. The data acquisition system is described and the paper concludes with a review of future test programs.

  10. Radiographic follow-up of community-acquired pneumonia in children.

    PubMed

    Surén, Pål; Try, Kirsti; Eriksson, Jan; Khoshnewiszadeh, Behzad; Wathne, Karl-Olaf

    2008-01-01

    To evaluate the value of radiographic follow-up of community-acquired pneumonia in children who are previously healthy. Patient records for the years 2003 and 2004 at the Ullevål University Hospital in Oslo were reviewed, and a total of 245 children were selected for the study. Radiographs were evaluated by two paediatric radiologists independently. One hundred and thirty-three patients had control radiographs, of which 106 were normal and 27 were abnormal. Only three of 27 patients with abnormal findings had further clinical problems that could be related to the pneumonia. Two of 106 with normal findings had further clinical problems, despite the normal control radiograph. Of the 112 without radiographic follow-up, 10 had subsequent clinical problems, but most occurred within the first 4 weeks after discharge, before controls would have been scheduled. There were five patients who may have benefited from controls. One relapse could theoretically have been prevented. Four patients were cases for whom the pneumonias were the first manifestations of chronic lung disease. Such patients may have some benefit from control radiographs, but only in terms of detecting the chronic disease at an earlier stage, not in altering the clinical course. Such modest benefits must be weighed against the consequences of providing follow-up to a large number of healthy children, and making lots of abnormal findings with no clinical significance. Control radiographs are not very valuable in children who are otherwise healthy.

  11. Reliability of panoramic radiograph for carotid atheroma detection: a study in patients who fulfill the criteria for carotid endarterectomy.

    PubMed

    Damaskos, Spyros; Griniatsos, John; Tsekouras, Nikolaos; Georgopoulos, Sotirios; Klonaris, Chris; Bastounis, Elias; Tsiklakis, Kostas

    2008-11-01

    To evaluate the reliability of panoramic radiograph (PR) for carotid artery atheroma detection, by comparing its results with the carotid-vertebral digital subtraction angiography (DSA) findings, as well as with the detected calcium deposition in the carotid plaques, which were surgically resected, using direct radiographs. Forty consecutive patients suffering from carotid artery atherosclerotic occlusive disease confirmed by preoperative DSA, fulfilling the criteria for carotid endarterectomy, were operated on. Preoperatively, all of the patients had undergone PR, while postoperatively all of the surgically resected carotid plaques were radiographed using radiographic films and submitted to histologic examination. Compared with the DSA and the radiographic film findings, the PR results were classified as: 1) true-positive; 2) true-negative; 3) false-positive; or 4) false-negative. Panoramic radiograph has low sensitivity and specificity compared with the DSA findings and the direct radiographs results. However, a positive predictive value (PPV) of 100% per patient as well as for luminal stenosis >80% was documented. Even in the subgroup of patients who fulfill the criteria for carotid endarterectomy, PR has a low sensitivity and specificity; therefore, it cannot be considered to be a useful screening tool for atheroma detection in the general dental population. However, the 100% PPV per patient and for luminal stenosis >80%, indicates that positive calcification PR findings at the C(3)-C(4) region are highly suggestive for carotid artery atherosclerotic occlusive disease. Therefore, especially asymptomatic patients should be referred for further examination.

  12. Coronal and Intraradicular Appearances Affect Radiographic Perception of the Periapical Region.

    PubMed

    Strong, Julie W; Woodmansey, Karl F; Khademi, John A; Hatton, John F

    2017-05-01

    The influence of the radiographic appearances of the coronal and intraradicular areas on periapical radiographic interpretation has been minimally evaluated in dentistry and endodontics. The purpose of this study was to evaluate the effects that the coronal and intraradicular radiographic appearance has on endodontists' radiographic interpretations of periapical areas. In a split-group study design using an online survey format, 2 pairs of digital periapical radiographic images were evaluated by 2 groups (A and B) of endodontist readers for the presence of a periapical finding. The images in each pair were identical except that 1 image of each image pairs had coronal restorations and/or root canal fillings altered using Adobe Photoshop software (Adobe Systems, San Jose, CA). The periapical areas were not altered. Using a 5-point Likert scale, the endodontist readers were asked to "Please evaluate the periapical area(s)." A Mann-Whitney U test was used to statistically evaluate the difference between the groups. Significance was set at P < .01. There were 417 readers in group A and 442 readers in group B. The Mann-Whitney U test showed a significant difference in the responses between the groups for both image pairs (P < .01). Because the periapical areas of the image pairs were unaltered, the differing coronal and intraradicular areas of the radiographs appear to have influenced endodontists' interpretations of the periapical areas. This finding has implications for all radiographic outcome assessments. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  13. Pit above the lesser tuberosity in axial view radiography.

    PubMed

    Cho, Jae-Ho; Han, Kyeong-Jin; Lee, Doo-Hyung; Chung, Nam-Su; Park, Do Young

    2015-02-01

    This study examined the relationship between the presence of a pit above the lesser tuberosity on axial view radiographs and rotator cuff tears and compared the demographic data between groups according to the presence of a pit above the lesser tuberosity. The hypothesis of this study was that the radiographic finding of a pit above the lesser tuberosity is related to rotator cuff tears. For 112 patients with a symptomatic rotator cuff tear, plain radiographs of the symptomatic shoulder (tear side radiographs) and plain radiographs of the asymptomatic contralateral shoulder (no-tear side radiographs) were assessed. Seventeen radiological findings, including a pit above the lesser tuberosity, osteophytes, subchondral cysts, and sclerosis, were recorded by one blinded observer. Demographic data such as age, duration of symptoms, sex, arm dominance, smoking history, trauma history, American Shoulder and Elbow Surgeons score, Constant score, and involved tendon were collected. A pit above the lesser tuberosity was noted on tear side radiographs of 40 patients (35.7 %) and on the no-tear side radiographs of 27 patients (24.1 %), representing a significant difference (P = 0.040). A pit associated with a rotator cuff tear was observed more often in the dominant arm (P = 0.040) and more often in patients with less previous trauma (P = 0.024). A pit above the lesser tuberosity on axial view radiography was associated with a rotator cuff tear and occurred more often in the dominant arm of patients who had no trauma history. Prognostic study, Level III.

  14. Correlation between radiographic findings of osteoarthritis and arthroscopic findings of articular cartilage degeneration within the patellofemoral joint.

    PubMed

    Kijowski, Richard; Blankenbaker, Donna; Stanton, Paul; Fine, Jason; De Smet, Arthur

    2006-12-01

    To correlate radiographic findings of osteoarthritis on axial knee radiographs with arthroscopic findings of articular cartilage degeneration within the patellofemoral joint in patients with chronic knee pain. The study group consisted of 104 patients with osteoarthritis of the patellofemoral joint and 30 patients of similar age with no osteoarthritis of the patellofemoral joint. All patients in the study group had an axial radiograph of the knee performed prior to arthroscopic knee surgery. At the time of arthroscopy, each articular surface of the patellofemoral joint was graded using the Noyes classification system. Two radiologists retrospectively reviewed the knee radiographs to determine the presence of marginal osteophytes, joint-space narrowing, subchondral sclerosis, and subchondral cysts. The sensitivity and specificity of the various radiographic features of osteoarthritis for the detection of articular cartilage degeneration within the patellofemoral joint were determined. The sensitivity of marginal osteophytes, joint-space narrowing, subchondral sclerosis, and subchondral cysts for the detection of articular cartilage degeneration within the patellofemoral joint was 73%, 37%, 4%, and 0% respectively. The specificity of marginal osteophytes, joint-space narrowing, subchondral sclerosis, and subchondral cysts for the detection of articular cartilage degeneration within the patellofemoral joint was 67%, 90%, 100%, and 100% respectively. Marginal osteophytes were the most sensitive radiographic feature for the detection of articular cartilage degeneration within the patellofemoral joint. Joint-space narrowing, subchondral sclerosis, and subchondral cysts were insensitive radiographic features of osteoarthritis, and rarely occurred in the absence of associated osteophyte formation.

  15. Plain film measurement error in acute displaced midshaft clavicle fractures

    PubMed Central

    Archer, Lori Anne; Hunt, Stephen; Squire, Daniel; Moores, Carl; Stone, Craig; O’Dea, Frank; Furey, Andrew

    2016-01-01

    Background Clavicle fractures are common and optimal treatment remains controversial. Recent literature suggests operative fixation of acute displaced mid-shaft clavicle fractures (DMCFs) shortened more than 2 cm improves outcomes. We aimed to identify correlation between plain film and computed tomography (CT) measurement of displacement and the inter- and intraobserver reliability of repeated radiographic measurements. Methods We obtained radiographs and CT scans of patients with acute DMCFs. Three orthopedic staff and 3 residents measured radiographic displacement at time zero and 2 weeks later. The CT measurements identified absolute shortening in 3 dimensions (by subtracting the length of the fractured from the intact clavicle). We then compared shortening measured on radiographs and shortening measured in 3 dimensions on CT. Interobserver and intraobserver reliability were calculated. Results We reviewed the fractures of 22 patients. Bland–Altman repeatability coefficient calculations indicated that radiograph and CT measurements of shortening could not be correlated owing to an unacceptable amount of measurement error (6 cm). Interobserver reliability for plain radiograph measurements was excellent (Cronbach α = 0.90). Likewise, intraobserver reliabilities for plain radiograph measurements as calculated with paired t tests indicated excellent correlation (p > 0.05 in all but 1 observer [p = 0.04]). Conclusion To establish shortening as an indication for DMCF fixation, reliable measurement tools are required. The low correlation between plain film and CT measurements we observed suggests further research is necessary to establish what imaging modality reliably predicts shortening. Our results indicate weak correlation between radiograph and CT measurement of acute DMCF shortening. PMID:27438054

  16. Radiographic abnormalities among construction workers exposed to quartz containing dust

    PubMed Central

    Tjoe, N; Burdorf, A; Parker, J; Attfield, M; van Duivenbooden, C; Heederik, D

    2003-01-01

    Background: Construction workers are exposed to quartz containing respirable dust, at levels that may cause fibrosis in the lungs. Studies so far have not established a dose-response relation for radiographic abnormalities for this occupational group. Aims: To measure the extent of radiographic abnormalities among construction workers primarily exposed to quartz containing respirable dust. Methods: A cross sectional study on radiographic abnormalities indicative of pneumoconiosis was conducted among 1339 construction workers mainly involved in grinding, (jack)-hammering, drilling, cutting, sawing, and polishing. Radiological abnormalities were determined by median results of the 1980 International Labour Organisation system of three certified "B" readers. Questionnaires were used for assessment of occupational history, presence of respiratory diseases, and symptoms and smoking habits. Results: An abnormality of ILO profusion category 1/0 and greater was observed on 10.2% of the chest radiographs, and profusion category of 1/1 or greater on 2.9% of the radiographs. The average duration of exposure of this group was 19 years and the average age was 42. The predominant type of small opacities (irregularly shaped) is presumably indicative of mixed dust pneumoconiosis. The prevalence of early signs of nodular silicosis (small rounded opacities of category 1/0 or greater) was low (0.8%). Conclusions: The study suggests an elevated risk of radiographic abnormalities among these workers with expected high exposure. An association between radiographic abnormalities and cumulative exposure to quartz containing dust from construction sites was observed, after correction for potentially confounding variables. PMID:12771392

  17. Langley Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Davis, Pamela A.; Stubbs, Sandy M.; Tanner, John A.

    1987-01-01

    The Langley Research Center has recently upgraded the Landing Loads Track (LLT) to improve the capability of low-cost testing of conventional and advanced landing gear systems. The unique feature of the Langley Aircraft Landing Dynamics Facility (ALDF) is the ability to test aircraft landing gear systems on actual runway surfaces at operational ground speeds and loading conditions. A historical overview of the original LLT is given, followed by a detailed description of the new ALDF systems and operational capabilities.

  18. RDHWT/MARIAH II Hypersonic Wind Tunnel Research Program

    DTIC Science & Technology

    2008-09-01

    Diagnostics Dr. Gary Brown – Gas Dynamics Dr. Ihab Girgis – Modeling Dr. Dennis Mansfield – Experimental Ring Technical Services Dr. Leon Ring – Systems...wind tunnel (MSHWT) with Mach 8 to 15, true -temperature flight test capabilities. This research program was initiated in fiscal year (FY) 1998 and is...Force test capabilities that exist today. Performance goals of the MSHWT are true temperature, Mach 8 to 15, dynamic pressure of 500 to 2000 psf (24 to

  19. Power capability evaluation for lithium iron phosphate batteries based on multi-parameter constraints estimation

    NASA Astrophysics Data System (ADS)

    Wang, Yujie; Pan, Rui; Liu, Chang; Chen, Zonghai; Ling, Qiang

    2018-01-01

    The battery power capability is intimately correlated with the climbing, braking and accelerating performance of the electric vehicles. Accurate power capability prediction can not only guarantee the safety but also regulate driving behavior and optimize battery energy usage. However, the nonlinearity of the battery model is very complex especially for the lithium iron phosphate batteries. Besides, the hysteresis loop in the open-circuit voltage curve is easy to cause large error in model prediction. In this work, a multi-parameter constraints dynamic estimation method is proposed to predict the battery continuous period power capability. A high-fidelity battery model which considers the battery polarization and hysteresis phenomenon is presented to approximate the high nonlinearity of the lithium iron phosphate battery. Explicit analyses of power capability with multiple constraints are elaborated, specifically the state-of-energy is considered in power capability assessment. Furthermore, to solve the problem of nonlinear system state estimation, and suppress noise interference, the UKF based state observer is employed for power capability prediction. The performance of the proposed methodology is demonstrated by experiments under different dynamic characterization schedules. The charge and discharge power capabilities of the lithium iron phosphate batteries are quantitatively assessed under different time scales and temperatures.

  20. 21 CFR 892.1950 - Radiographic anthropomorphic phantom.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... purposes to simulate a human body for positioning radiographic equipment. (b) Classification. Class I... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiographic anthropomorphic phantom. 892.1950 Section 892.1950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  1. 21 CFR 892.1950 - Radiographic anthropomorphic phantom.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... purposes to simulate a human body for positioning radiographic equipment. (b) Classification. Class I... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiographic anthropomorphic phantom. 892.1950 Section 892.1950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  2. 21 CFR 892.1950 - Radiographic anthropomorphic phantom.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... purposes to simulate a human body for positioning radiographic equipment. (b) Classification. Class I... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiographic anthropomorphic phantom. 892.1950 Section 892.1950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  3. Radiographer.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. Center on Education and Training for Employment.

    This document, which is designed for use in developing a tech prep competency profile for the occupation of radiographer, lists technical competencies and competency builders for 18 units pertinent to the health technologies cluster in general as well as those specific to the occupation of radiographer. The following skill areas are covered in the…

  4. 21 CFR 892.1950 - Radiographic anthropomorphic phantom.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... purposes to simulate a human body for positioning radiographic equipment. (b) Classification. Class I... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic anthropomorphic phantom. 892.1950 Section 892.1950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  5. 21 CFR 892.1950 - Radiographic anthropomorphic phantom.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... purposes to simulate a human body for positioning radiographic equipment. (b) Classification. Class I... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiographic anthropomorphic phantom. 892.1950 Section 892.1950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  6. 42 CFR Appendix B to Part 75 - Standards for Accreditation of Dental Radiography Training for Dental Hygienists

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...: defining the curriculum in terms of program goals, instructional objectives, learning experiences designed... making radiographs. Faculty supervision must be provided during a student's radiographic technique experience. Students must demonstrate competence in making diagnostically acceptable radiographs prior to...

  7. 42 CFR Appendix B to Part 75 - Standards for Accreditation of Dental Radiography Training for Dental Hygienists

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...: defining the curriculum in terms of program goals, instructional objectives, learning experiences designed... making radiographs. Faculty supervision must be provided during a student's radiographic technique experience. Students must demonstrate competence in making diagnostically acceptable radiographs prior to...

  8. 42 CFR Appendix B to Part 75 - Standards for Accreditation of Dental Radiography Training for Dental Hygienists

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...: defining the curriculum in terms of program goals, instructional objectives, learning experiences designed... making radiographs. Faculty supervision must be provided during a student's radiographic technique experience. Students must demonstrate competence in making diagnostically acceptable radiographs prior to...

  9. 42 CFR Appendix B to Part 75 - Standards for Accreditation of Dental Radiography Training for Dental Hygienists

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...: defining the curriculum in terms of program goals, instructional objectives, learning experiences designed... making radiographs. Faculty supervision must be provided during a student's radiographic technique experience. Students must demonstrate competence in making diagnostically acceptable radiographs prior to...

  10. 21 CFR 892.1970 - Radiographic ECG/respirator synchronizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic ECG/respirator synchronizer. 892.1970 Section 892.1970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1970 Radiographic ECG/respirator...

  11. 21 CFR 892.1920 - Radiographic head holder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic head holder. 892.1920 Section 892.1920 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1920 Radiographic head holder. (a...

  12. Real-time scene and signature generation for ladar and imaging sensors

    NASA Astrophysics Data System (ADS)

    Swierkowski, Leszek; Christie, Chad L.; Antanovskii, Leonid; Gouthas, Efthimios

    2014-05-01

    This paper describes development of two key functionalities within the VIRSuite scene simulation program, broadening its scene generation capabilities and increasing accuracy of thermal signatures. Firstly, a new LADAR scene generation module has been designed. It is capable of simulating range imagery for Geiger mode LADAR, in addition to the already existing functionality for linear mode systems. Furthermore, a new 3D heat diffusion solver has been developed within the VIRSuite signature prediction module. It is capable of calculating the temperature distribution in complex three-dimensional objects for enhanced dynamic prediction of thermal signatures. With these enhancements, VIRSuite is now a robust tool for conducting dynamic simulation for missiles with multi-mode seekers.

  13. A dynamically reconfigurable multi-functional PLL for SRAM-based FPGA in 65nm CMOS technology

    NASA Astrophysics Data System (ADS)

    Yang, Mingqian; Chen, Lei; Li, Xuewu; Zhang, Yanlong

    2018-04-01

    Phase-locked loops (PLL) have been widely utilized in FPGA as an important module for clock management. PLL with dynamic reconfiguration capability is always welcomed in FPGA design as it is able to decrease power consumption and simultaneously improve flexibility. In this paper, a multi-functional PLL with dynamic reconfiguration capability for 65nm SRAM-based FPGA is proposed. Firstly, configurable charge pump and loop filter are utilized to optimize the loop bandwidth. Secondly, the PLL incorporates a VCO with dual control voltages to accelerate the adjustment of oscillation frequency. Thirdly, three configurable dividers are presented for flexible frequency synthesis. Lastly, a configuration block with dynamic reconfiguration function is proposed. Simulation results demonstrate that the proposed multi-functional PLL can output clocks with configurable division ratio, phase shift and duty cycle. The PLL can also be dynamically reconfigured without affecting other parts' running or halting the FPGA device.

  14. Monochromatic x-ray radiography for areal-density measurement of inertial fusion energy fuel in fast ignition experiment.

    PubMed

    Fujioka, Shinsuke; Fujiwara, Takashi; Tanabe, Minoru; Nishimura, Hiroaki; Nagatomo, Hideo; Ohira, Shinji; Inubushi, Yuichi; Shiraga, Hiroyuki; Azechi, Hiroshi

    2010-10-01

    Ultrafast, two-dimensional x-ray imaging is an important diagnostics for the inertial fusion energy research, especially in investigating implosion dynamics at the final stage of the fuel compression. Although x-ray radiography was applied to observing the implosion dynamics, intense x-rays emitted from the high temperature and dense fuel core itself are often superimposed on the radiograph. This problem can be solved by coupling the x-ray radiography with monochromatic x-ray imaging technique. In the experiment, 2.8 or 5.2 keV backlight x-rays emitted from laser-irradiated polyvinyl chloride or vanadium foils were selectively imaged by spherically bent quartz crystals with discriminating the out-of-band emission from the fuel core. This x-ray radiography system achieved 24 μm and 100 ps of spatial and temporal resolutions, respectively.

  15. The effect of a dominant initial single mode on the Kelvin–Helmholtz instability evolution: New insights on previous experimental results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shimony, Assaf; Shvarts, Dov; Malamud, Guy

    2016-04-12

    This paper brings new insights on an experiment, measuring the Kelvin–Helmholtz (KH) instability evolution, performed on the OMEGA-60 laser facility. Experimental radiographs show that the initial seed perturbations in the experiment are of multimode spectrum with a dominant single-mode of 16 μm wavelength. In single-mode-dominated KH instability flows, the mixing zone (MZ) width saturates to a constant value comparable to the wavelength. However, the experimental MZ width at late times has exceeded 100 μm, an order of magnitude larger. In this work, we use numerical simulations and a statistical model in order to investigate the vortex dynamics of the KHmore » instability for the experimental initial spectrum. Here, we conclude that the KH instability evolution in the experiment is dominated by multimode, vortex-merger dynamics, overcoming the dominant initial mode.« less

  16. High-frame-rate digital radiographic videography

    NASA Astrophysics Data System (ADS)

    King, Nicholas S. P.; Cverna, Frank H.; Albright, Kevin L.; Jaramillo, Steven A.; Yates, George J.; McDonald, Thomas E.; Flynn, Michael J.; Tashman, Scott

    1994-10-01

    High speed x-ray imaging can be an important tool for observing internal processes in a wide range of applications. In this paper we describe preliminary implementation of a system having the eventual goal of observing the internal dynamics of bone and joint reactions during loading. Two Los Alamos National Laboratory (LANL) gated and image intensified camera systems were used to record images from an x-ray image convertor tube to demonstrate the potential of high frame-rate digital radiographic videography in the analysis of bone and joint dynamics of the human body. Preliminary experiments were done at LANL to test the systems. Initial high frame-rate imaging (from 500 to 1000 frames/s) of a swinging pendulum mounted to the face of an X-ray image convertor tube demonstrated high contrast response and baseline sensitivity. The systems were then evaluated at the Motion Analysis Laboratory of Henry Ford Health Systems Bone and Joint Center. Imaging of a 9 inch acrylic disk with embedded lead markers rotating at approximately 1000 RPM, demonstrated the system response to a high velocity/high contrast target. By gating the P-20 phosphor image from the X-ray image convertor with a second image intensifier (II) and using a 100 microsecond wide optical gate through the second II, enough prompt light decay from the x-ray image convertor phosphor had taken place to achieve reduction of most of the motion blurring. Measurement of the marker velocity was made by using video frames acquired at 500 frames/s. The data obtained from both experiments successfully demonstrated the feasibility of the technique. Several key areas for improvement are discussed along with salient test results and experiment details.

  17. Altered spinal motion in low back pain associated with lumbar strain and spondylosis.

    PubMed

    Cheng, Joseph S; Carr, Christopher B; Wong, Cyrus; Sharma, Adrija; Mahfouz, Mohamed R; Komistek, Richard D

    2013-04-01

    Study Design We present a patient-specific computer model created to translate two-dimensional (2D) fluoroscopic motion data into three-dimensional (3D) in vivo biomechanical motion data. Objective The aim of this study is to determine the in vivo biomechanical differences in patients with and without acute low back pain. Current dynamic imaging of the lumbar spine consists of flexion-extension static radiographs, which lack sensitivity to out-of-plane motion and provide incomplete information on the overall spinal motion. Using a novel technique, in-plane and coupled out-of-plane rotational motions are quantified in the lumbar spine. Methods A total of 30 participants-10 healthy asymptomatic subjects, 10 patients with low back pain without spondylosis radiologically, and 10 patients with low back pain with radiological spondylosis-underwent dynamic fluoroscopy with a 3D-to-2D image registration technique to create a 3D, patient-specific bone model to analyze in vivo kinematics using the maximal absolute rotational magnitude and the path of rotation. Results Average overall in-plane rotations (L1-L5) in patients with low back pain were less than those asymptomatic, with the dominant loss of motion during extension. Those with low back pain also had significantly greater out-of-plane rotations, with 5.5 degrees (without spondylosis) and 7.1 degrees (with spondylosis) more out-of-plane rotational motion per level compared with asymptomatic subjects. Conclusions Subjects with low back pain exhibited greater out-of-plane intersegmental motion in their lumbar spine than healthy asymptomatic subjects. Conventional flexion-extension radiographs are inadequate for evaluating motion patterns of lumbar strain, and assessment of 3D in vivo spinal motion may elucidate the association of abnormal vertebral motions and clinically significant low back pain.

  18. Reconfigurable metasurface aperture for security screening and microwave imaging

    NASA Astrophysics Data System (ADS)

    Sleasman, Timothy; Imani, Mohammadreza F.; Boyarsky, Michael; Pulido-Mancera, Laura; Reynolds, Matthew S.; Smith, David R.

    2017-05-01

    Microwave imaging systems have seen growing interest in recent decades for applications ranging from security screening to space/earth observation. However, hardware architectures commonly used for this purpose have not seen drastic changes. With the advent of metamaterials a wealth of opportunities have emerged for honing metasurface apertures for microwave imaging systems. Recent thrusts have introduced dynamic reconfigurability directly into the aperture layer, providing powerful capabilities from a physical layer with considerable simplicity. The waveforms generated from such dynamic metasurfaces make them suitable for application in synthetic aperture radar (SAR) and, more generally, computational imaging. In this paper, we investigate a dynamic metasurface aperture capable of performing microwave imaging in the K-band (17.5-26.5 GHz). The proposed aperture is planar and promises an inexpensive fabrication process via printed circuit board techniques. These traits are further augmented by the tunability of dynamic metasurfaces, which provides the dexterity necessary to generate field patterns ranging from a sequence of steered beams to a series of uncorrelated radiation patterns. Imaging is experimentally demonstrated with a voltage-tunable metasurface aperture. We also demonstrate the aperture's utility in real-time measurements and perform volumetric SAR imaging. The capabilities of a prototype are detailed and the future prospects of general dynamic metasurface apertures are discussed.

  19. 42 CFR 37.50 - Interpreting and classifying chest radiographs-film.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Interpreting and classifying chest radiographs-film. 37.50 Section 37.50 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Interpreting and classifying chest radiographs—film. (a) Chest radiographs must be interpreted and classified...

  20. 42 CFR 37.45 - Protection against radiation emitted by radiographic equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Protection against radiation emitted by radiographic equipment. 37.45 Section 37.45 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN....45 Protection against radiation emitted by radiographic equipment. Except as otherwise specified in...

  1. 42 CFR Appendix C to Part 75 - Standards for Accreditation of Dental Radiography Training for Dental Assistants

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... curriculum in terms of program goals, instructional objectives, learning experiences designed to achieve... must be provided during a student's radiographic technique experience. Students must demonstrate... provide opportunity to make a variety of radiographs and radiographic surveys, including primary, mixed...

  2. 42 CFR Appendix C to Part 75 - Standards for Accreditation of Dental Radiography Training for Dental Assistants

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... curriculum in terms of program goals, instructional objectives, learning experiences designed to achieve... must be provided during a student's radiographic technique experience. Students must demonstrate... provide opportunity to make a variety of radiographs and radiographic surveys, including primary, mixed...

  3. 42 CFR Appendix C to Part 75 - Standards for Accreditation of Dental Radiography Training for Dental Assistants

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... curriculum in terms of program goals, instructional objectives, learning experiences designed to achieve... must be provided during a student's radiographic technique experience. Students must demonstrate... provide opportunity to make a variety of radiographs and radiographic surveys, including primary, mixed...

  4. 42 CFR Appendix C to Part 75 - Standards for Accreditation of Dental Radiography Training for Dental Assistants

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... curriculum in terms of program goals, instructional objectives, learning experiences designed to achieve... must be provided during a student's radiographic technique experience. Students must demonstrate... provide opportunity to make a variety of radiographs and radiographic surveys, including primary, mixed...

  5. 10 CFR 34.23 - Locking of radiographic exposure devices, storage containers and source changers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Locking of radiographic exposure devices, storage containers and source changers. 34.23 Section 34.23 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment...

  6. 10 CFR 34.23 - Locking of radiographic exposure devices, storage containers and source changers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Locking of radiographic exposure devices, storage containers and source changers. 34.23 Section 34.23 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment...

  7. 10 CFR 34.23 - Locking of radiographic exposure devices, storage containers and source changers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Locking of radiographic exposure devices, storage containers and source changers. 34.23 Section 34.23 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment...

  8. 10 CFR 34.23 - Locking of radiographic exposure devices, storage containers and source changers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Locking of radiographic exposure devices, storage containers and source changers. 34.23 Section 34.23 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment...

  9. 10 CFR 34.23 - Locking of radiographic exposure devices, storage containers and source changers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Locking of radiographic exposure devices, storage containers and source changers. 34.23 Section 34.23 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment...

  10. Two-dimensional high spatial-resolution dosimeter using europium doped potassium chloride: a feasibility study

    NASA Astrophysics Data System (ADS)

    Li, H. Harold; Driewer, Joseph P.; Han, Zhaohui; Low, Daniel A.; Yang, Deshan; Xiao, Zhiyan

    2014-04-01

    Recent research has shown that KCl:Eu2+ has great potential for use in megavoltage radiation therapy dosimetry because this material exhibits excellent storage performance and is reusable due to strong radiation hardness. This work reports the authors’ attempts to fabricate 2D KCl:Eu2+ storage phosphor films (SPFs) using both a physical vapor deposition (PVD) method and a tape casting method. X-ray diffraction analysis showed that a 10 µm thick PVD sample was composed of highly crystalline KCl. No additional phases were observed, suggesting that the europium activator had been completely incorporated into the KCl matrix. Photostimulated luminescence and photoluminescence spectra suggested that F (Cl-) centers were the electron storage centers post x-ray irradiation and that Eu2+ cations acted as luminescence centers in the photostimulation process. The 150 µm thick casted KCl:Eu2+ SPF showed sub-millimeter spatial-resolution. Monte Carlo simulations further demonstrated that the admixture of 20% KCl:Eu2+ and 80% low Z polymer binder exhibited almost no energy-dependence in a 6 MV beam. KCl:Eu2+ pellet samples showed a large dynamic range from 0.01 cGy to 60 Gy dose-to-water, and saturated at approximately 500 Gy as a result of KCl's intrinsic high radiation hardness. Taken together, this work provides strong evidence that KCl:Eu2+-based SPF with associated readout apparatus could result in a novel electronic film system that has all the desirable features associated with classic radiographic film and, importantly, water equivalence and the capability of permanent identification of each detector.

  11. Display And Analysis Of Tomographic Volumetric Images Utilizing A Vari-Focal Mirror

    NASA Astrophysics Data System (ADS)

    Harris, L. D.; Camp, J. J.

    1984-10-01

    A system for the three-dimensional (3-D) display and analysis of stacks of tomographic images is described. The device utilizes the principle of a variable focal (vari-focal) length optical element in the form of an aluminized membrane stretched over a loudspeaker to generate a virtual 3-D image which is a visible representation of a 3-D array of image elements (voxels). The system displays 500,000 voxels per mirror cycle in a 3-D raster which appears continuous and demonstrates no distracting artifacts. The display is bright enough so that portions of the image can be dimmed without compromising the number of shades of gray. For x-ray CT, a displayed volume image looks like a 3-D radiograph which appears to be in the space directly behind the mirror. The viewer sees new views by moving his/her head from side to side or up and down. The system facilitates a variety of operator interactive functions which allow the user to point at objects within the image, control the orientation and location of brightened oblique planes within the volume, numerically dissect away selected image regions, and control intensity window levels. Photographs of example volume images displayed on the system illustrate, to the degree possible in a flat picture, the nature of displayed images and the capabilities of the system. Preliminary application of the display device to the analysis of volume reconstructions obtained from the Dynamic Spatial Reconstructor indicates significant utility of the system in selecting oblique sections and gaining an appreciation of the shape and dimensions of complex organ systems.

  12. Development of optimized techniques and requirements for computer enhancement of structural weld radiographs. Volume 1: Technical report

    NASA Technical Reports Server (NTRS)

    Adams, J. R.; Hawley, S. W.; Peterson, G. R.; Salinger, S. S.; Workman, R. A.

    1971-01-01

    A hardware and software specification covering requirements for the computer enhancement of structural weld radiographs was considered. Three scanning systems were used to digitize more than 15 weld radiographs. The performance of these systems was evaluated by determining modulation transfer functions and noise characteristics. Enhancement techniques were developed and applied to the digitized radiographs. The scanning parameters of spot size and spacing and film density were studied to optimize the information content of the digital representation of the image.

  13. Dual-energy KUB radiographic examination for the detection of renal calculus.

    PubMed

    Yen, Peggy; Bailly, Greg; Pringle, Christopher; Barnes, David

    2014-08-01

    The dual-energy radiographic technique has been proved to be clinically useful in the thorax. Herein, we attempt to apply this technique to the abdomen and pelvis in the context of renal colic. The visibility of renal calculi were assessed using various dual energy peak kilovoltage combination radiographs applied to standard phantoms. This technique demonstrates a higher than acceptable radiation dosage required to optimize the image quality and the optimized diagnostic quality is inferior to that of the standard Kidneys, Ureters, and Bladder radiograph. The dual-energy radiographic technique could not better identify the radiopaque renal calculi. Limiting technical considerations include the increased subcutaneous and peritoneal adipose tissue and the limited contrast between the soft tissue and underlying calculi. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  14. Radiographic localization of unerupted teeth: further findings about the vertical tube shift method and other localization techniques.

    PubMed

    Jacobs, S G

    2000-10-01

    The parallax method (image/tube shift method, Clark's rule, Richards' buccal object rule) is recommended to localize unerupted teeth. Richards' contribution to the development of the parallax method is discussed. The favored method for localization uses a rotational panoramic radiograph in combination with an occlusal radiograph involving a vertical shift of the x-ray tube. The use of this combination when localizing teeth and supernumeraries in the premolar region is illustrated. When taking an occlusal radiograph to localize an unerupted maxillary canine, clinical situations are presented where modification of the vertical angulation of the tube of 70 degrees to 75 degrees or of the horizontal position of the tube is warranted. The limitations of axial (true, cross-sectional, vertex) occlusal radiographs are also explored.

  15. Are plain radiographs sufficient to exclude cervical spine injuries in low-risk adults?

    PubMed

    Hunter, Benton R; Keim, Samuel M; Seupaul, Rawle A; Hern, Gene

    2014-02-01

    The routine use of clinical decision rules and three-view plain radiography to clear the cervical spine in blunt trauma patients has been recently called into question. In low-risk adult blunt trauma patients, can plain radiographs adequately exclude cervical spine injury when clinical prediction rules cannot? Four observational studies investigating the performance of plain radiographs in detecting cervical spine injury in low-risk adult blunt trauma patients were reviewed. The consistently poor performance of plain radiographs to rule out cervical spine injury in adult blunt trauma victims is concerning. Large, rigorously performed prospective trials focusing on low- or low/moderate-risk patients will be needed to truly define the utility of plain radiographs of the cervical spine in blunt trauma. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Method for producing three-dimensional real image using radiographic perspective views of an object

    DOEpatents

    Ellingson, William A.; Read, Alvin A.

    1976-02-24

    A sequence of separate radiographs are made by indexing a radiation source along a known path relative to the object under study. Thus, each radiograph contains information from a different perspective. A holographically-recorded image is then made from each radiographic perspective by exact re-tracing of the rays through each radiographic perspective such that the re-tracing duplicates the geometry under which it was originally prepared. The holographically-stored images are simultaneously illuminated with the conjugate of the reference beam used in the original recordings. The result is the generation of a three-dimensional real image of the object such that a light-sensitive device can be moved to view the real image along any desired surface with the optical information in all other surfaces greatly suppressed.

  17. Quantitative analysis of the plain radiographic appearance of nonossifying fibroma.

    PubMed

    Friedland, J A; Reinus, W R; Fisher, A J; Wilson, A J

    1995-08-01

    To quantitate radiographic features that distinguish the plain radiographic appearance of nonossifying fibroma (NOF) from other solitary lesions of bone. Seven hundred nine cases of focal bone lesions, including 34 NOFs, were analyzed according to demographic, anatomic, and plain radiographic features. Vector analysis of groups of features was performed to determine those that are most sensitive and specific for the appearance of NOF in contrast to other lesions in the data base. The radiographic appearance of NOFs was most consistently a medullary based (97%), lytic lesion (100%) with geographic bone destruction (100%), marginal sclerosis (97%), and well-defined edges (94%). A statistically significant number of lesions were located in the distal aspect of long bones. Unicameral bone cyst shared the most radiographic features with the NOF. Vector analysis showed a large degree of overlap between NOF and other lesions such as aneurysmal bone cyst, chondromyxoid fibroma, and eosinophilic granuloma. The description that optimized sensitivity and prevalence for detection of NOF is a medullary based, ovoid lesion in the distal or proximal portions of a long bone with well-defined edges, a partial or complete rind of sclerosis, and absence of fallen fragment, periosteal reaction, and cortical disruption. The radiographic appearance of NOF is relatively nonspecific but, using vector analysis, can be better elucidated over current textbook descriptions.

  18. A new bite block for panoramic radiographs of anterior edentulous patients: A technical report.

    PubMed

    Park, Jong-Woong; Symkhampha, Khanthaly; Huh, Kyung-Hoe; Yi, Won-Jin; Heo, Min-Suk; Lee, Sam-Sun; Choi, Soon-Chul

    2015-06-01

    Panoramic radiographs taken using conventional chin-support devices have often presented problems with positioning accuracy and reproducibility. The aim of this report was to propose a new bite block for panoramic radiographs of anterior edentulous patients that better addresses these two issues. A new panoramic radiography bite block similar to the bite block for dentulous patients was developed to enable proper positioning stability for edentulous patients. The new bite block was designed and implemented in light of previous studies. The height of the new bite block was 18 mm and to compensate for the horizontal edentulous space, its horizontal width was 7 mm. The panoramic radiographs using the new bite block were compared with those using the conventional chin-support device. Panoramic radiographs taken with the new bite block showed better stability and bilateral symmetry than those taken with the conventional chin-support device. Patients also showed less movement and more stable positioning during panoramic radiography with the new bite block. Conventional errors in panoramic radiographs of edentulous patients could be caused by unreliability of the chin-support device. The newly proposed bite block for panoramic radiographs of edentulous patients showed better reliability. Further study is required to evaluate the image quality and reproducibility of images with the new bite block.

  19. Routine Chest Radiographs After Central Line Insertion: Mandatory Postprocedural Evaluation or Unnecessary Waste of Resources?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lucey, Brian; Varghese, Jose C.; Haslam, Philip

    1999-09-15

    Purpose: To study the cost and impact on patient management of the routine performance of chest radiographs in patients undergoing imaged-guided central venous catheter insertion. Methods: Six hundred and twenty-one catheters placed in 489 patients over a 42-month period formed the study group. Catheters were placed in the right internal jugular vein (425), left internal jugular vein (133), and subclavian veins (63). At the end of the procedure fluoroscopy was used to assess catheter position and check for complications. A postprocedural chest radiograph was obtained in all patients. Results: Postprocedural chest fluoroscopy showed no evidence of pneumothorax, hemothorax, or mediastinalmore » hematoma. Inappropriate catheter tip position or catheter kinks were noted with 90 catheters. These problems were all corrected while the patient was on the interventional table. Postprocedural chest radiographs showed no complications but proximal catheter tip migration was noted in six of 621 catheters (1%). These latter six catheters required further manipulation. The total technical and related charges for the postprocedural chest radiographs in this series were estimated at Pounds 15,525. Conclusion: Postprocedural chest radiographs after image-guided central venous catheter insertion are not routinely required. A postprocedural chest radiograph can be performed on a case-by-case basis at the discretion of the interventional radiologist.« less

  20. Prediction of age and gender using digital radiographic method: A retrospective study.

    PubMed

    Poongodi, V; Kanmani, R; Anandi, M S; Krithika, C L; Kannan, A; Raghuram, P H

    2015-08-01

    To investigate age, sex based on gonial angle, width and breadth of the ramus of the mandible by digital orthopantomograph. A total of 200 panoramic radiographic images were selected. The age of the individuals ranged between 4 and 75 years of both the gender - males (113) and females (87) and selected radiographic images were measured using KLONK image measurement software tool with linear, angular measurement. The investigated radiographs were collected from the records of SRM Dental College, Department of Oral Medicine and Radiology. Radiographs with any pathology, facial deformities, if no observation of mental foramen, congenital deformities, magnification, and distortion were excluded. Mean, median, standard deviation, derived to check the first and third quartile, linear regression is used to check age and gender correlation with angle of mandible, height and width of the ramus of mandible. The radiographic method is a simpler and cost-effective method of age identification compared with histological and biochemical methods. Mandible is strongest facial bone after the skull, pelvic bone. It is validatory to predict age and gender by many previous studies. Radiographic and tomographic images have become an essential aid for human identification in forensic dentistry forensic dentists can choose the most appropriate one since the validity of age and gender estimation crucially depends on the method used and its proper application.

  1. Appearance of the weight-bearing lateral radiograph in retrocalcaneal bursitis

    PubMed Central

    Muller, Bart; Maas, Mario; Sierevelt, Inger N; van Dijk, C Niek

    2010-01-01

    Background and purpose A retrocalcaneal bursitis is caused by repetitive impingement of the bursa between the Achilles tendon and the posterosuperior calcaneus. The bursa is situated in the posteroinferior corner of Kager's triangle (retrocalcaneal recess), which is a radiolucency with sharp borders on the lateral radiograph of the ankle. If there is inflammation, the fluid-filled bursa is less radiolucent, making it difficult to delineate the retrocalcaneal recess. We assessed whether the radiographic appearance of the retrocalcaneal recess on plain digital (filmless) radiographs could be used in the diagnosis of a retrocalcaneal bursitis. Methods Whether or not there was obliteration of the retrocalcaneal recess (yes/no) on 74 digital weight-bearing lateral radiographs of the ankle was independently assessed by 2 observers. The radiographs were from 24 patients (25 heels) with retrocalcaneal bursitis (confirmed on endoscopic calcaneoplasty); the control group consisted of 50 patients (59 heels). Results The sensitivity of the test was 83% for observer 1 and 79% for observer 2. Specificity was 100% and 98%, respectively. The kappa value of the interobserver reliability test was 0.86. For observer 1, intraobserver reliability was 0.96 and for observer 2 it was 0.92. Interpretation On digital weight-bearing lateral radiographs of a retrocalcaneal bursitis, the retrocalcaneal recess has a typical appearance. PMID:20450438

  2. Radiographic inspection of porosity in pure titanium dumbbell castings.

    PubMed

    Nuñez, Juliana Maria Costa; Takahashi, Jessica Mie Ferreira Koyama; Henriques, Guilherme Elias Pessanha; Nóbilo, Mauro Antônio de Arruda; Consani, Rafael Leonardo Xediek; Mesquita, Marcelo Ferraz

    2011-09-01

      Titanium frameworks are frequently indicated for implant supported prostheses; however, voids are usually encountered inside cast titanium.   This study aimed to confirm the efficacy of a radiographic technique for inspection of porosity in commercially pure titanium castings with different diameter.   Sixty dumbbell rods (n=20) with a central 1.5, 2.0 and 3.5mm diameter were prepared by lost-wax casting. Cast specimens were finished and polished and submitted to radiographic examination (90kV, 15mA, 0.6s and 10-13mm of distance) using periapical film. The radiographs were visually analysed for the presence of porosity in the extension of the dumbbell or in the central portion of the rods. Data were submitted to Pearson Chi-square test (5%).   The tested radiographic method proved to be suitable for the evaluation of cast frameworks. Internal porosities were observed in most of the specimens (91.7%) (p=0.0005); however, only 20% occurred on the central portion of the rods (p=0.612).   Internal porosities can be visualised through radiographs and occur mostly in small diameter structures. The radiographic evaluation of metal structures can improve the quality of frameworks and thereby potentially increase the longevity of the rehabilitation. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  3. Digital radiograph of the middle phalanx of the third finger (MP3) region as a tool for skeletal maturity assessment.

    PubMed

    Hegde, Deepa Y; Baliga, Sudhindra; Yeluri, Ramakrishna; Munshi, A K

    2012-01-01

    To evaluate the reliability of the digital radiograph of the middle phalanx of the third finger (MP3) in skeletal maturity assessment. Fifty children (24 girls and 26 boys) belonging to the circumpubertal age-group were selected for the study. Two radiographs - lateral cephalogram and digital radiograph of the MP3 region - were taken in each child. Age assessment was based on the changes in shape of the cervical vertebrae and the epiphysis of the middle phalanx of the third finger of the left hand. The radiographs were assessed by three examiners. The inter- and intraexaminer variability were determined by the Wilcoxon rank sign test and the Kruskal-Wallis test and were found to be nonsignificant. Examiner 3 showed the best intraexaminer agreement and was selected to evaluate the radiographs for the entire study. The correlation determined between the MP3 stages and cervical vertebrae maturity index (CVMI) stages, the peak-wise distribution of the MP3 stages, and the correlation between the MP3 stages and the chronological age were found to be highly significant. Digital radiograph of the MP3 region is definitely a simple, reliable, cost-effective, and time-saving technique for the assessment of skeletal maturity.

  4. Radiographic measurement of internal organs in Spix's macaws (Cyanopsitta spixii).

    PubMed

    Rettmer, Helen; Deb, Amrita; Watson, Ryan; Hatt, Jean-Michel; Hammer, Sven

    2011-12-01

    Radiology is an important diagnostic instrument in avian medicine, but standard measurement ranges for the objective evaluation of radiographs of birds are rare. To establish radiographic reference ranges for the critically endangered Spix's macaw (Cyanopsitta spixii), we measured radiographic silhouettes of the heart, liver, kidneys, spleen, proventriculus, and keel of the sternum on 29 radiographs taken under standardized conditions in adult and juvenile, clinically healthy birds. Ratios were determined for the proventricular diameter-to-keel height, the width of the heart to the width of the thorax, and for the "hourglass shape" (ratio of the width of the heart to the width of the liver). No significant differences were found between the sexes among the adult birds. Compared with adult birds, juvenile females had a significantly larger heart width (19.8 +/- 1.4 mm versus 21.2 +/- 0.7 mm), ratio of the heart width to the thorax width (0.86 +/- 0.08 versus 0.94 +/- 0.09), and horizontal width of the spleen (7.7 +/- 0.6 mm versus 8.5 +/- 0.4 mm). Results of radiographic measurements in the Spix's macaws were comparable to those published from other psittacine species. These reference ranges will facilitate a more objective radiographic evaluation of captive Spix's macaws.

  5. Segmentation and determination of joint space width in foot radiographs

    NASA Astrophysics Data System (ADS)

    Schenk, O.; de Muinck Keizer, D. M.; Bernelot Moens, H. J.; Slump, C. H.

    2016-03-01

    Joint damage in rheumatoid arthritis is frequently assessed using radiographs of hands and feet. Evaluation includes measurements of the joint space width (JSW) and detection of erosions. Current visual scoring methods are timeconsuming and subject to inter- and intra-observer variability. Automated measurement methods avoid these limitations and have been fairly successful in hand radiographs. This contribution aims at foot radiographs. Starting from an earlier proposed automated segmentation method we have developed a novel model based image analysis algorithm for JSW measurements. This method uses active appearance and active shape models to identify individual bones. The model compiles ten submodels, each representing a specific bone of the foot (metatarsals 1-5, proximal phalanges 1-5). We have performed segmentation experiments using 24 foot radiographs, randomly selected from a large database from the rheumatology department of a local hospital: 10 for training and 14 for testing. Segmentation was considered successful if the joint locations are correctly determined. Segmentation was successful in only 14%. To improve results a step-by-step analysis will be performed. We performed JSW measurements on 14 randomly selected radiographs. JSW was successfully measured in 75%, mean and standard deviation are 2.30+/-0.36mm. This is a first step towards automated determination of progression of RA and therapy response in feet using radiographs.

  6. Educational Module Intervention for Radiographers to Reduce Repetition Rate of Routine Digital Chest Radiography in Makkah Region of Saudi Arabia Tertiary Hospitals: Protocol of a Quasi-Experimental Study.

    PubMed

    Almalki, Abdullah A; Abdul Manaf, Rosliza; Hanafiah Juni, Muhamad; Kadir Shahar, Hayati; Noor, Noramaliza Mohd; Gabbad, Abdelsafi

    2017-09-26

    Repetition of an image is a critical event in any radiology department. When the repetition rate of routine digital chest radiographs is high, radiation exposure of staff and patients is increased. In addition, repetition consumes the equipment's life span, thus affecting the annual budget of the department. The aim of this study is to determine the impact of a printed educational module on reducing the repetition rate of routine digital chest radiography among radiographers in Makkah Region tertiary hospitals. A quasi-experimental time series with a control group will be conducted in Makkah Region tertiary hospitals for 8 months starting in the second quarter of 2017. Four hospitals out of 5 in the region will be selected; 2 of them will be selected as the control group and the other 2 as the intervention group. Stratification and a simple random sampling technique will be used to sample 56 radiographers in each group. Pre- and postintervention assessments will be conducted to determine the radiographer knowledge, motivation, and skills and repetition rate of chest radiographs. Radiographs of the chest performed by sampled radiographers in the selected hospitals will be collected for 2 weeks before and after the intervention. A piloted questionnaire will be distributed and collected by a researcher in both groups. One-way multivariate analysis of variance and 2-way repeated multivariate analysis of variance will be used to analyze the data. It is expected that the repetition rate in the intervention group will decline after implementing the intervention and the change will be statistically significant (P<.05). Furthermore, it is expected that the knowledge, motivation, and skill levels in the intervention group will increase significantly among radiographers after implementation of the intervention (P<.05). Meanwhile, knowledge, motivation, and skills in the control group will not change. A quasi-experimental time series with a control will be conducted to investigate the effect of printed educational material in reducing the repetition rate of routine digital chest radiographs among radiographers in tertiary hospitals in the Makkah Region of Saudi Arabia. ©Abdullah A. Almalki, Rosliza Abdul Manaf, Muhamad Hanafiah Juni, Hayati Kadir Shahar, Noramaliza Mohd Noor, Abdelsafi Gabbad. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 26.09.2017.

  7. Competing on capabilities: the new rules of corporate strategy.

    PubMed

    Stalk, G; Evans, P; Shulman, L E

    1992-01-01

    In the 1980s, companies discovered time as a new source of competitive advantage. In the 1990s, they will discover that time is only one piece of a more far-reaching transformation in the logic of competition. Using examples from Wal-Mart and other highly successful companies, Stalk, Evans, and Shulman of the Boston Consulting Group provide managers with a guide to the new world of "capabilities-based competition." In today's dynamic business environment, strategy too must become dynamic. Competition is a "war of movement" in which success depends on anticipation of market trends and quick response to changing customer needs. In such an environment, the essence of strategy is not the structure of a company's products and markets but the dynamics of its behavior. To succeed, a company must weave its key business processes into hard-to-imitate strategic capabilities that distinguish it from its competitors in the eyes of customers. A capability is a set of business processes strategically understood--for example, Wal-Mart's expertise in inventory replenishment, Honda's skill at dealer management, or Banc One's ability to "out-local the national banks and out-national the local banks." Such capabilities are collective and cross-functional--a small part of many people's jobs, not a large part of a few. Finally, competing on capabilities requires strategic investments in support systems that span traditional SBUs and functions and go far beyond what traditional cost-benefit metrics can justify. A CEO's success in building and managing a company's capabilities will be the chief test of management skill in the 1990s. The prize: companies that combine scale and flexibility to outperform the competition.

  8. Radiographic Diagnosis of Pincer-Type Femoroacetabular Impingement: A Systematic Review.

    PubMed

    Rhee, Chanseok; Le Francois, Tina; Byrd, J W Thomas; Glazebrook, Mark; Wong, Ivan

    2017-05-01

    Femoroacetabular impingement (FAI) is a well-recognized condition that causes hip pain and can lead to early osteoarthritis if not managed properly. With the increasing awareness and efficacy of operative treatments for pincer-type FAI, there is a need for consensus on the standardized radiographic diagnosis. To perform a systematic review of the evidence regarding imaging modalities and radiographic signs for diagnosing pincer-type FAI. Systematic review; Level of evidence, 4. A literature review was performed in 2016 using the Cochrane, PubMed, and Embase search engines. All articles focusing on a radiographic diagnosis of pincer-type FAI were reviewed. Each of the included 44 articles was assigned the appropriate level of evidence, and the particular radiographic marker and/or type of imaging were also summarized. There were 44 studies included in the final review. Most of the articles were level 4 evidence (26 articles), and there were 12 level 3 and 6 level 2 articles. The crossover sign was the most commonly used radiographic sign (27/44) followed by the lateral center-edge angle (22/44). Anteroposterior (AP) pelvis plain radiographs were the most commonly used imaging modality (33 studies). Poor-quality evidence exists in support of most currently used radiographic markers, including the crossover sign, lateral center-edge angle, posterior wall sign, ischial spine sign, coxa profunda, acetabular protrusion, and acetabular index. There is poor-quality conflicting evidence regarding the use of the herniation pit to diagnose pincer-type FAI. Some novel measurements, such as β-angle, acetabular roof ratio, and acetabular retroversion index, have been proposed, but they also lack support from the literature. No strong evidence exists to support a single best set of current radiographic markers for the diagnosis of pincer-type FAI, largely due to the lack of better quality trials (levels 1 and 2) that compare conventional radiographic findings with the gold standard, which is the intraoperative findings. More sophisticated imaging modalities such as computed tomography and magnetic resonance arthrography are often needed to diagnose pincer-type FAI, and these investigations are relatively accurate in assessing labral pathology or cartilage damage.

  9. An evaluation of the periapical status of teeth with necrotic pulps using periapical radiography and cone-beam computed tomography.

    PubMed

    Abella, F; Patel, S; Durán-Sindreu, F; Mercadé, M; Bueno, R; Roig, M

    2014-04-01

    To evaluate the presence or absence of periapical (PA) radiolucencies on individual roots of teeth with necrotic pulps, as assessed with digital PA radiographs and cone-beam computed tomography (CBCT). Digital PA radiographs and CBCT scans were taken from 161 endodontically untreated teeth (from 155 patients) diagnosed with non-vital pulps (pulp necrosis with normal PA tissue, symptomatic apical periodontitis, asymptomatic apical periodontitis, acute apical abscess and chronic apical abscess). Images were assessed by two calibrated endodontists to analyse the radiographic PA status of the teeth. A consensus was reached in the event of any disagreement. The data were analysed using a McNemar's test, and significance was set at P ≤ 0.05. Three hundred and forty paired images of roots were assessed with both digital PA radiographs and CBCT images. Fifteen additional roots were identified with CBCT. PA radiolucencies were present in 132 (38.8%) roots when assessed with PA radiographs, and in 196 (57.6%) roots when assessed with CBCT. This difference was statistically significant (P < 0.05). In teeth diagnosed with pulp necrosis, symptomatic apical periodontitis or acute apical abscess, CBCT images revealed a statistically larger number of PA radiolucencies than did PA radiographs (P < 0.05). No statistical differences were observed between PA radiographs and CBCT in teeth classified with asymptomatic apical periodontitis (P = 0.31) or chronic apical abscess (P = 1). Unlike PA radiographs, CBCT revealed a higher prevalence of PA radiolucencies when endodontically untreated teeth with non-vital pulps were examined. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  10. Utility of complete trauma series radiographs in alert pediatric patients presenting to Emergency Department of a Tertiary Care Hospital.

    PubMed

    Alam Khan, T; Jamil Khattak, Y; Awais, M; Alam Khan, A; Husen, Y; Nadeem, N; Rehman, A

    2015-06-01

    To assess the utility of trauma series radiographs in the management of alert pediatric patients with traumatic injury and to ascertain whether it is necessary to acquire the entire trauma series in these children. A total of 176 consecutive children below the age of 15 years and having Glasgow Coma Scale score greater than 12, who presented to the emergency department of a tertiary care hospital with a history of recent trauma, were retrospectively reviewed. All the children had undergone a thorough clinical examination followed by complete trauma series radiographs, according to the American College of Surgery guidelines. A total of 558 radiographs were reviewed by a consultant pediatric radiologist including 528 trauma series radiographs and 30 additional radiographs. Among the trauma series radiographs, 35 (6.63 %) had evidence of injury; 24 (4.54 %) and 11 (2.08 %) involving the chest and pelvic regions, respectively. All children with normal physical examination had normal cervical spine and chest radiographs. Among the 11 positive pelvic X-rays, only two had radiological signs of injury in the absence of localizing physical signs, and all these children were less than 3 years of age. In all the remaining cases, children had localizing signs on physical examination. Out of the 30 additional X-rays, 27 (90 %) had radiological evidence of injury. The routine use of entire radiological trauma series in alert pediatric patients with a normal physical examination has a very low yield. In these children, the localizing signs and symptoms can help us in determining the specific radiological examination to be utilized.

  11. Association between the Presence of Apical Periodontitis and Clinical Symptoms in Endodontic Patients Using Cone-beam Computed Tomography and Periapical Radiographs.

    PubMed

    Weissman, Jake; Johnson, James D; Anderson, Melissa; Hollender, Lars; Huson, Tim; Paranjpe, Avina; Patel, Shanon; Cohenca, Nestor

    2015-11-01

    Cone-beam computed tomographic (CBCT) imaging is a valuable adjunct to endodontic practice. Among the endodontic applications of CBCT imaging, it aids in the diagnosis of apical periodontitis, often in cases in which there is no evidence of pathosis identified by conventional imaging. The purpose of this study was to correlate the presence of apical periodontitis of teeth evaluated with 2-dimensional periapical (PA) radiographs and 3-dimensional CBCT volumes with clinical signs and symptoms. Clinical records were reviewed from patients examined at the graduate endodontics clinic. The examination included clinical examination, sensibility tests, PA radiographs, and limited field-of-view CBCT scans. Of 498 cases, 67 fulfilled the inclusion criteria and were evaluated for apical periodontitis and symptomology. CBCT slices and PA radiographs were evaluated by 2 board-certified endodontists and a board-certified oral and maxillofacial radiologist for the presence of apical periodontitis. Thirty eight of 67 teeth showed the presence of apical radiolucencies on PA radiographs and on CBCT imaging, whereas 14 teeth had no evidence of apical radiolucencies on either imaging modality. Fifteen cases showed the presence of apical radiolucencies visible on CBCT imaging that were not visible on PA radiographic images. The presence of apical radiolucencies on CBCT slices and PA radiographic images was correlated with clinical signs and symptoms, including the chief complaint. This research has important implications to prevent overexposure to radiation and to provide treatment for those patients with persistent symptoms lacking proper diagnosis based on conventional (2D) radiographs. Copyright © 2015. Published by Elsevier Inc.

  12. Radiographers' professional knowledge regarding parameters and safety issues in plain radiography: a questionnaire survey.

    PubMed

    Farajollahi, A R; Fouladi, D F; Ghojazadeh, M; Movafaghi, A

    2014-08-01

    To review the knowledge of radiographers and examine the possible sociodemographic and situational contributors to this knowledge. A questionnaire survey was devised and distributed to a cohort of 120 radiographers. Each questionnaire contained two sections. In the first section, background data, including sex, age, highest academic level, grade point average (GPA), length of time from graduation, work experience as a radiographer and the status of previous refresher course(s), were collected. The second section contained 17 multiple-choice questions concerning radiographic imaging parameters and safety issues. The response rate was 63.8%. In univariate analytic model, higher academic degree (p < 0.001), higher GPA (r(2) = 0.11; p = 0.001), academic workplace (p = 0.04) and taking previous refresher course(s) (p = 0.01) were significantly associated with higher knowledge score. In multivariate analytic model, however, higher academic degree (B = 1.62; p = 0.01), higher GPA (B = 0.50; p = 0.01) and taking previous refresher course(s) (B = -1.26; p = 0.03) were independently associated with higher level of knowledge. Age, sex, length of time from graduation and work experience were not associated with the respondents' knowledge score. Academic background is a robust indicator of a radiographer's professional knowledge. Refresher courses and regular knowledge assessments are highly recommended. This is the first study in the literature that examines professional knowledge of radiographers in terms of technical and safety issues in plain radiography. Academic degree, GPA and refresher courses are independent predictors of this knowledge. Regular radiographer professional knowledge checks may be recommended.

  13. High-resolution axial MR imaging of tibial stress injuries

    PubMed Central

    2012-01-01

    Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries. PMID:22574840

  14. Effects of Different Viewing Conditions on Radiographic Interpretation

    PubMed Central

    Moshfeghi, Mahkameh; Shahbazian, Majid; Sajadi, Soodabeh Sadat; Sajadi, Sepideh; Ansari, Hossein

    2015-01-01

    Objectives: Optimum viewing conditions facilitate identification of radiographic details and decrease the need for retakes, patients’ costs and radiation dose. This study sought to evaluate the effects of different viewing conditions on radiographic interpretation. Materials and Methods: This diagnostic study was performed by evaluating radiograph of a 7mm-thick aluminum block, in which 10 holes with 2mm diameters were randomly drilled with depths ranging from 0.05 mm to 0.50mm. The radiograph was viewed by four oral radiologists independently under four viewing conditions, including a white light viewing light box in a lit room, yellow light viewing light box in a lit room, white light viewing light box in a dark room and yellow light viewing light box in a dark room. Number of circular shadows observed on the film was recorded. The data were analyzed by two-way ANOVA. Results: The mean number of detected circular shadows was 6.75, 7.5, 7.25 and 7.75 in white light viewing light box in a lit room, white light viewing light box in a dark room, yellow light viewing light box in a lit room and yellow light viewing light box in a dark room, respectively. Although the surrounding illumination had statistically significant effect on the radiographic details (P≤0.03), the light color of the viewing light box had no significant effect on visibility of the radiographic details. Conclusion: White and yellow light of the viewing light box had no significant effect on visibility of the radiographic details but more information was obtained in a dark room. PMID:27507997

  15. Effects of Different Viewing Conditions on Radiographic Interpretation.

    PubMed

    Moshfeghi, Mahkameh; Shahbazian, Majid; Sajadi, Soodabeh Sadat; Sajadi, Sepideh; Ansari, Hossein

    2015-11-01

    Optimum viewing conditions facilitate identification of radiographic details and decrease the need for retakes, patients' costs and radiation dose. This study sought to evaluate the effects of different viewing conditions on radiographic interpretation. This diagnostic study was performed by evaluating radiograph of a 7mm-thick aluminum block, in which 10 holes with 2mm diameters were randomly drilled with depths ranging from 0.05 mm to 0.50mm. The radiograph was viewed by four oral radiologists independently under four viewing conditions, including a white light viewing light box in a lit room, yellow light viewing light box in a lit room, white light viewing light box in a dark room and yellow light viewing light box in a dark room. Number of circular shadows observed on the film was recorded. The data were analyzed by two-way ANOVA. The mean number of detected circular shadows was 6.75, 7.5, 7.25 and 7.75 in white light viewing light box in a lit room, white light viewing light box in a dark room, yellow light viewing light box in a lit room and yellow light viewing light box in a dark room, respectively. Although the surrounding illumination had statistically significant effect on the radiographic details (P≤0.03), the light color of the viewing light box had no significant effect on visibility of the radiographic details. White and yellow light of the viewing light box had no significant effect on visibility of the radiographic details but more information was obtained in a dark room.

  16. High Variability of Observed Weight Bearing During Standing Foot and Ankle Radiographs.

    PubMed

    Miller, Christopher P; Ghorbanhoseini, Mohammad; Ehrlichman, Lauren K; Walley, Kempland C; Ghaheri, Azadeh; Kwon, John Y

    2017-06-01

    Weight-bearing radiographs are a critical component of evaluating foot and ankle pathology. An underlying assumption is that patients are placing 50% of their body weight on the affected foot during image acquisition. The accuracy of weight bearing during radiographs is unknown and, presumably, variable, which may result in uncertain ability of the resultant radiographs to appropriately portray the pathology of interest. Fifty subjects were tested. The percentage body weight through the foot of interest was measured at the moment of radiographic image acquisition. The subject was then instructed to bear "half [their] weight" prior to the next radiograph. The percentage body weight was calculated and compared to ideal 50% weight bearing. The mean percentage body weight in trial 1 and 2 was 45.7% ± 3.2% ( P = .012 compared to the 50% mark) and 49.2% ± 2.4%, respectively ( P = .428 compared to 50%). The mean absolute difference in percentage weight bearing compared to 50% in trials 1 and 2 was 9.3% ± 2.3% and 5.8% ± 1.8%, respectively ( P = .005). For trial 1, 18/50 subjects were within the "ideal" (45%-55%) range for weight bearing compared to 32/50 on trial 2 ( P = .005). In trial 1, 24/50 subjects had "appropriate" (>45%) weight bearing compared to 39/50 on trial 2 ( P = .002). There was substantial variability in the weight applied during radiograph acquisition. This study raises questions regarding the assumptions, reliability, and interpretation when evaluating weight-bearing radiographs. Level III, comparative study.

  17. Previous radiographic experience of children referred for dental extractions under general anaesthesia in the U.K.

    PubMed

    Young, N L; Rodd, H D; Craig, S A

    2009-03-01

    To determine what proportion of children undergo radiographic assessment prior to referral to a dental hospital for extractions under general anaesthesia. This prospective survey was conducted over a 6-month period. A data sheet was used to record the following information: patient's age; referrer's name and place of work (general dental practice or community dental service); teeth to be extracted (primary dentition and/or permanent dentition) and reported previous radiographic examination. Patients were excluded from the study if, following a clinical examination, radiographs were not actually deemed necessary for diagnosis and treatment planning purposes. Clinical setting A paediatric dentistry clinic within a dental hospital in the North of England. Participants 161 patients with a mean age of six years (SD = 2.2, range = 3-14 years) who were referred to the dental hospital for extractions under general anaesthesia. Overall, 12.4% of children had reportedly undergone a previous radiographic assessment prior to hospital referral. A significantly greater proportion of children referred for permanent tooth extractions had been subject to radiographic examination compared to children referred for primary tooth extractions (46.2% as compared to 6.3%; P = 0.001 chi-squared test). Furthermore, patients referred from the community dental service were significantly more likely to have had previous dental radiographs than children referred from general dental practice (36.9% compared to 9.3%; P = 0.003 chi-squared test). Radiographs do not appear to be routinely employed for caries diagnosis and treatment planning in young children within general dental practice in the U.K.

  18. Supply and demand for radiographers in Lithuania: a prognosis for 2012-2030.

    PubMed

    Vanckaviciene, Aurika; Starkiene, Liudvika; Macijauskiene, Jūrate

    2014-07-01

    This is the first ever study on the planning of the supply and demand for radiographers in Lithuania. The aim of this study was to analyze the supply and demand for radiographers in the labor market with respect to their number, structure, and services, and to provide a prognosis for the period of 2012-2030. Supply was calculated using two scenarios with differing duration of studies, annual student drop-out rates, rates of failure to start working, the annual number of new entrants into the labor market, and emigration rates. Annual mortality rates, the number of first-year students, and retirement rates were evaluated equally in both scenarios. Two projections of the demand for radiographers, based on the population's differing (by age and gender), need for outpatient radiology services, computed tomography, and magnetic resonance scans. Subsequently, the supply and demand scenarios were compared. Evaluation of the perspective supply and demand scenarios - which are the most probable - revealed a gap forming during the analyzed period, the predicted specialist shortage will reach 0.13 full-time equivalents per 10,000 population, and in 2030-0.37 full-time equivalents per 10,000 population. Considering the changes in education of radiographers, the socio-demographic characteristics of the staff, and the increasing need for radiographers' services, the supply of radiographers during the next two decades will be insufficient. To meet the forecasted demand for radiographers in the perspective scenario, the number of students choosing this specialty from 2013 on should increase by up to 30%. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  19. Improving the diagnostic quality and adequacy of shoulder radiographs in a District General Hospital

    PubMed Central

    Richards, Bethany; Riley, James; Saithna, Adnan

    2016-01-01

    A high rate of suboptimal shoulder radiographs was identified during a service evaluation exercise in our orthopaedic outpatient clinics. Inadequate radiographs require a return to the radiology department for further imaging, a resultant increased workload, delays in the clinic, increased radiation for patients, and inconvenience and decreased patient satisfaction. Furthermore, if a sub-optimal radiograph is accepted there is concern that diagnoses may be missed. The aim of this project was to decrease the rate of suboptimal radiographs by delivering a teaching package directed towards quality improvement. Evaluation criteria were set for standard orthopaedic shoulder radiographs (Anterior-posterior, axillary, and Velpeau views). Baseline data collection was performed over three, two-week periods and included all patients attending the shoulder clinic. The percentage of x-rays which were deemed adequate was only 19.4% for anterior-posterior views and 57.9% for axillary views. A comprehensive educational package was delivered to radiographers. This included a formal PowerPoint based teaching session, hands on training with practice using a skeleton, posters with step-by step instructions on how to obtain an adequate image, and PDF aide memoires suitable for viewing on a smartphone. Two subsequent two-week periods of data collection were performed to evaluate the benefit of this intervention. Delivery of focussed training and provision of easily accessible aide memoires to facilitate improved quality of radiographs resulted in a significant (p<0.05) reduction in the rate of inadequate images. There was also a significant decreases in the rate of return to the radiology department for repeat imaging. PMID:27559473

  20. Core Technical Capability Laboratory Management System

    NASA Technical Reports Server (NTRS)

    Shaykhian, Linda; Dugger, Curtis; Griffin, Laurie

    2008-01-01

    The Core Technical Capability Lab - oratory Management System (CTCLMS) consists of dynamically generated Web pages used to access a database containing detailed CTC lab data with the software hosted on a server that allows users to have remote access.

Top