40 CFR 91.305 - Dynamometer specifications and calibration accuracy.
Code of Federal Regulations, 2011 CFR
2011-07-01
... specifications. (1) The dynamometer test stand and other instruments for measurement of engine speed and torque... accuracy. (1) The dynamometer test stand and other instruments for measurement of engine torque and speed...
40 CFR 91.305 - Dynamometer specifications and calibration accuracy.
Code of Federal Regulations, 2014 CFR
2014-07-01
... specifications. (1) The dynamometer test stand and other instruments for measurement of engine speed and torque... accuracy. (1) The dynamometer test stand and other instruments for measurement of engine torque and speed...
40 CFR 91.305 - Dynamometer specifications and calibration accuracy.
Code of Federal Regulations, 2013 CFR
2013-07-01
... specifications. (1) The dynamometer test stand and other instruments for measurement of engine speed and torque... accuracy. (1) The dynamometer test stand and other instruments for measurement of engine torque and speed...
40 CFR 91.305 - Dynamometer specifications and calibration accuracy.
Code of Federal Regulations, 2010 CFR
2010-07-01
... specifications. (1) The dynamometer test stand and other instruments for measurement of engine speed and torque... accuracy. (1) The dynamometer test stand and other instruments for measurement of engine torque and speed...
40 CFR 91.305 - Dynamometer specifications and calibration accuracy.
Code of Federal Regulations, 2012 CFR
2012-07-01
... specifications. (1) The dynamometer test stand and other instruments for measurement of engine speed and torque... accuracy. (1) The dynamometer test stand and other instruments for measurement of engine torque and speed...
40 CFR 90.305 - Dynamometer specifications and calibration accuracy.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (a) Dynamometer specifications. The dynamometer test stand and other instruments for measurement of speed and power output must meet the engine speed and torque accuracy requirements shown in Table 2 in... measurement of power output must meet the calibration frequency shown in Table 2 in Appendix A of this subpart...
40 CFR 90.305 - Dynamometer specifications and calibration accuracy.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (a) Dynamometer specifications. The dynamometer test stand and other instruments for measurement of speed and power output must meet the engine speed and torque accuracy requirements shown in Table 2 in... measurement of power output must meet the calibration frequency shown in Table 2 in Appendix A of this subpart...
40 CFR 90.305 - Dynamometer specifications and calibration accuracy.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (a) Dynamometer specifications. The dynamometer test stand and other instruments for measurement of speed and power output must meet the engine speed and torque accuracy requirements shown in Table 2 in... measurement of power output must meet the calibration frequency shown in Table 2 in Appendix A of this subpart...
40 CFR 90.305 - Dynamometer specifications and calibration accuracy.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (a) Dynamometer specifications. The dynamometer test stand and other instruments for measurement of speed and power output must meet the engine speed and torque accuracy requirements shown in Table 2 in... measurement of power output must meet the calibration frequency shown in Table 2 in Appendix A of this subpart...
40 CFR 90.305 - Dynamometer specifications and calibration accuracy.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (a) Dynamometer specifications. The dynamometer test stand and other instruments for measurement of speed and power output must meet the engine speed and torque accuracy requirements shown in Table 2 in... measurement of power output must meet the calibration frequency shown in Table 2 in Appendix A of this subpart...
Investigation of Data Fusion Applied to Health Monitoring of Wind Turbine Drive train Components
NASA Technical Reports Server (NTRS)
Dempsey, Paula J.; Sheng, Shuangwen
2011-01-01
The research described was performed on diagnostic tools used to detect damage to dynamic mechanical components in a wind turbine gearbox. Different monitoring technologies were evaluated by collecting vibration and oil debris data from tests performed on a "healthy" gearbox and a damaged gearbox in a dynamometer test stand located at the National Renewable Energy Laboratory. The damaged gearbox tested was removed from the field after experiencing component damage due to two losses of oil events and was retested under controlled conditions in the dynamometer test stand. Preliminary results indicate oil debris and vibration can be integrated to assess the health of the wind turbine gearbox.
Abe, Takashi; Loenneke, Jeremy P; Thiebaud, Robert S; Loftin, Mark
2017-10-16
Studies developed the frail elderly handgrip strength (HGS) diagnostic criteria using multiple types of handgrip dynamometers. If different handgrip dynamometer report different values, then this would have the potential to misclassify people into the wrong diagnostic category. To examine the characteristics of HGS measured by two standard handgrip dynamometers, and to investigate the influence of hand size on HGS. University research laboratory. 87 young and middle-aged adults aged 20-60 years participated in this study. Standard methods of HGS measurements were used for hydraulic and Smedley's spring-type dynamometer, although the participants were instructed to maintain an upright standing position in both tests. Test-retest reliability of hydraulic and Smedley dynamometers provided comparable results to that observed with previous studies. However, the difference in HGS between the two dynamometers (Hydraulic-Smedley difference) was positively associated (r = 0.670, p < 0.001) with the mean of the two dynamometers. The participants who had relatively low HGS (at least <35 kg) produced similar HGS values when the two dynamometers were compared, while persons who had relatively higher HGS (at least >45 kg) produced greater strength values with the hydraulic compared to the Smedley. The hand and palm lengths were weakly correlated (r = 0.349 and r = 0.358, respectively, both p < 0.001) to the difference in HGS between the two dynamometers. Test-retest reliability of hydraulic and Smedley dynamometers provides comparable results to previous studies. However, the difference in HGS between the two dynamometers was positively associated with the mean of the two dynamometers. This Hydraulic-Smedley difference would not affect persons who have relatively low HGS (at least < 35 kg), while when HGS is relatively high, the comparison between dynamometers should be done with caution.
Design verification tests for an axial gap permanent magnet compressor motor
NASA Astrophysics Data System (ADS)
Hawsey, R. A.; Bailey, J. M.
1987-07-01
A 30-hp, direct-drive, permanent magnet motor (PMM) has been constructed. The motor is to operate at 15,000 rpm and is designed to drive a Worthington compressor at the US DOE-owned gaseous diffusion plants. The PMM prevents traditional dynamometer testing, including locked rotor current, voltage, and torque measurements. A test plan is presented for data acquisition on the dynamometer test stand in order to calculate the equivalent circuit for the motor. A description of the hardware required for these measurements is included in the plan.
Testing the Hip Abductor Muscle Strength of Older Persons Using a Handheld Dynamometer.
Awwad, Daniel H; Buckley, Jonathan D; Thomson, Rebecca L; O'Connor, Matthew; Carbone, Tania A; Chehade, Mellick J
2017-09-01
To investigate the reliability of a clinically applicable method of dynamometry to assess and monitor hip abductor muscle strength in older persons. Bilateral isometric hip abductor muscle strength measured with a handheld dynamometer, patients supine with the contralateral hip positioned directly against a wall for stabilization. Reliability determined by comparing intra-assessor and inter-assessor results and comparison to a criterion standard (stabilized dynamometer with patients in the standing position). UniSA Nutritional Physiology Research Centre. Twenty-one patients older than 65 years were recruited from the Royal Adelaide Hospital. Intraclass correlation coefficients (ICCs), bias, and limits of agreement calculated to determine reliability. Intra-assessor and inter-assessor ICCs were high (0.94 and 0.92-0.94, respectively). There was no intra-assessor bias and narrow limits of agreement (±2.4%). There was a small inter-assessor bias but narrow limits of agreement (0.6%-0.9% and ± 2.3%, respectively). There was a wide variation comparing results to the criterion standard (±5.0%-5.2% limits of agreement), highlighting problems attributed to difficulties that the test population had with the standing position used in the criterion standard test. Testing older persons' hip abductor muscle strength while in the supine position with optimal pelvic stabilization using a handheld dynamometer is highly reliable. While further studies must be done to assess patients with specific pathologies, this test has potential application to monitor and evaluate the effects of surgical interventions and/or rehabilitation protocols for a variety of conditions affecting hip abductor function such as hip fractures and arthritis.
40 CFR 86.312-79 - Dynamometer and engine equipment specifications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... test stand and other instruments for measurement of power output shall be accurate to within 2 percent... system must have a single tail pipe. For engines designed for a dual exhaust system, a standard or...
40 CFR 91.328 - Measurement equipment accuracy/calibration frequency table.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Emission Test... appendix A to this subpart are met. (f) Verify that all NDIR analyzers meet the water rejection ratio and the CO2 rejection ratio as specified in § 91.325. (g) Verify that the dynamometer test stand and power...
NASA Technical Reports Server (NTRS)
McArdle, Jack G.; Barth, Richard L.; Wenzel, Leon M.; Biesiadny, Thomas J.
1996-01-01
A convertible engine called the CEST TF34, using the variable inlet guide vane method of power change, was tested on an outdoor stand at the NASA Lewis Research Center with a waterbrake dynamometer for the shaft load. A new digital electronic system, in conjunction with a modified standard TF34 hydromechanical fuel control, kept engine operation stable and safely within limits. All planned testing was completed successfully. Steady-state performance and acoustic characteristics were reported previously and are referenced. This report presents results of transient and dynamic tests. The transient tests measured engine response to several rapid changes in thrust and torque commands at constant fan (shaft) speed. Limited results from dynamic tests using the pseudorandom binary noise technique are also presented. Performance of the waterbrake dynamometer is discussed in an appendix.
NASA Astrophysics Data System (ADS)
Belkin, A. E.; Semenov, V. K.
2016-05-01
We consider the problem of modeling the test where a solid-rubber tire runs on a chassis dynamometer for determining the tire rolling resistance characteristics.We state the problem of free steady-state rolling of the tire along the test drum with the energy scattering in the rubber in the course of cyclic deformation taken into account. The viscoelastic behavior of the rubber is described by the Bergströ m-Boyce model whose numerical parameters are experimentally determined from the results of compression tests with specimens. The finite element method is used to obtain the solution of the three-dimensional viscoelasticity problem. To estimate the adequacy of the constructed model, we compare the numerical results with the results obtained in the solid-rubber tire tests on the Hasbach stand from the values of the rolling resistance forces for various loads on the tire.
NASA Technical Reports Server (NTRS)
Hannum, Richard W; Zimmerman, Richard H
1945-01-01
Calculations based on dynamometer test-stand data obtained on an 18-cylinder radial engine were made to determine the improvement in fuel consumption that can be obtained at various altitudes by gearing an exhaust-gas turbine to the engine crankshaft in order to increase the engine-shaft work.
Test stand performance of a convertible engine for advanced V/STOL and rotorcraft propulsion
NASA Technical Reports Server (NTRS)
Mcardle, Jack G.
1987-01-01
A variable inlet guide vane (VIGV) convertible engine that could be used to power future high-speed V/STOL and rotorcraft was tested on an outdoor stand. The engine ran stably and smoothly in the turbofan, turboshaft, and dual (combined fan and shaft) power modes. In the turbofan mode with the VIGV open, fuel consumption was comparable to that of a conventional turbofan engine. In the turboshaft mode with the VIGV closed, fuel consumption was higher than that of present turboshaft engines because power was wasted in churning fan-tip air flow. In dynamic performance tests with a specially built digital engine control and using a waterbrake dynamometer for shaft load, the engine responded effectively to large steps in thrust command and shaft torque.
Test stand performance of a convertible engine for advanced V/STOL and rotorcraft propulsion
NASA Technical Reports Server (NTRS)
Mcardle, Jack G.
1988-01-01
A variable inlet guide vane (VIGV) convertible engine that could be used to power future high-speed V/STOL and rotorcraft was tested on an outdoor stand. The engine ran stably and smoothly in the turbofan, turboshaft, and dual (combined fan and shaft) power modes. In the turbofan mode with the VIGV open, fuel consumption was comparable to that of a conventional turbofan engine. In the turboshaft mode with the VIGV closed, fuel consumption was higher than that of present turboshaft engines because power was wasted in churning fan-tip air flow. In dynamic performance tests with a specially built digital engine control and using a waterbrake dynamometer for shaft load, the engine responded effectively to large steps in thrust command and shaft torque.
HEAVY-DUTY VEHICLE IN USE EMISSION PERFORMANCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nylund, N; Ikonen, M; Laurikko, J
2003-08-24
Engines for heavy-duty vehicles are emission certified by running engines according to specified load pattern or duty cycle. In the US, the US Heavy-Duty Transient cycle has been in use already for a number of years, and Europe is, according to the requirements of the Directive 1999/96/EC gradually switching to transient-type testing. Evaluating the in-use emission performance of heavy-duty vehicles presents a problem. Taking engines out of vehicles for engine dynamometer testing is difficult and costly. In addition, engine dynamometer testing does not take into account the properties of the vehicle itself (i.e. mass, transmission etc.). It is also debatable,more » how well the standardized duty cycles reflect real-life -driving patterns. VTT Processes has recently commissioned a new emission laboratory for heavy-duty vehicles. The facility comprises both engine test stand and a fully transient heavy-duty chassis dynamometer. The roller diameter of the dynamometer is 2.5 meters. Regulated emissions are measured using a full-flow CVS system. The HD vehicle chassis dynamometer measurements (emissions, fuel consumption) has been granted accreditation by the Centre of Metrology and Accreditation (MIKES, Finland). A national program to generate emission data on buses has been set up for the years 2002-2004. The target is to generate emission factors for some 50 different buses representing different degree of sophistication (Euro 1 to Euro5/EEV, with and without exhaust gas aftertreatment), different fuel technologies (diesel, natural gas) and different ages (the effect of aging). The work is funded by the Metropolitan Council of Helsinki, Helsinki City Transport, The Ministry of Transport and Communications Finland and the gas company Gasum Oy. The International Association for Natural Gas Vehicles (IANGV) has opted to buy into the project. For IANGV, VTT will deliver comprehensive emission data (including particle size distribution and chemical and biological characterization of particles) for up-to-date diesel and natural gas vehicles. The paper describes the methodology used for the measurements on buses, the test matrix and some preliminary emission data on both regulated and unregulated emissions.« less
Rafn, Bolette S; Tang, Lars; Nielsen, Martin P; Branci, Sonia; Hölmich, Per; Thorborg, Kristian
2016-05-01
To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. Cross-sectional study. Clinical assessments at Sports Orthopaedic Research Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. Twenty-four male soccer players with unilateral long-standing hip and groin pain. The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion, adduction, abduction, isometric hip flexion-modified Thomas test, and eccentric hip adduction). Muscle strength was measured with a hand-held dynamometer, and the players rated the pain during testing on a numerical rating scale (0-10). In 4 tests (isometric hip adduction, abduction, flexion, and eccentric adduction), no significant correlations were found between pain during testing and hip muscle strength (Spearman rho = -0.28 to 0.06, P = 0.09-0.39). Isometric hip flexion (modified Thomas test position) showed a moderate negative correlation between pain and hip muscle strength (Spearman rho = -0.44, P = 0.016). Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain.
40 CFR 90.409 - Engine dynamometer test run.
Code of Federal Regulations, 2014 CFR
2014-07-01
...). (3) Record all pre-test data specified in § 90.405(c). (4) Start the test cycle (see § 90.410) within... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine dynamometer test run. 90.409... Test Procedures § 90.409 Engine dynamometer test run. (a) Engine and dynamometer start-up. (1) Only...
40 CFR 90.409 - Engine dynamometer test run.
Code of Federal Regulations, 2010 CFR
2010-07-01
...). (3) Record all pre-test data specified in § 90.405(c). (4) Start the test cycle (see § 90.410) within... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine dynamometer test run. 90.409... Test Procedures § 90.409 Engine dynamometer test run. (a) Engine and dynamometer start-up. (1) Only...
40 CFR 90.409 - Engine dynamometer test run.
Code of Federal Regulations, 2013 CFR
2013-07-01
...). (3) Record all pre-test data specified in § 90.405(c). (4) Start the test cycle (see § 90.410) within... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine dynamometer test run. 90.409... Test Procedures § 90.409 Engine dynamometer test run. (a) Engine and dynamometer start-up. (1) Only...
40 CFR 90.409 - Engine dynamometer test run.
Code of Federal Regulations, 2012 CFR
2012-07-01
...). (3) Record all pre-test data specified in § 90.405(c). (4) Start the test cycle (see § 90.410) within... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine dynamometer test run. 90.409... Test Procedures § 90.409 Engine dynamometer test run. (a) Engine and dynamometer start-up. (1) Only...
40 CFR 90.409 - Engine dynamometer test run.
Code of Federal Regulations, 2011 CFR
2011-07-01
...). (3) Record all pre-test data specified in § 90.405(c). (4) Start the test cycle (see § 90.410) within... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine dynamometer test run. 90.409... Test Procedures § 90.409 Engine dynamometer test run. (a) Engine and dynamometer start-up. (1) Only...
Effect of STS space suit on astronaut dominant upper limb EVA work performance
NASA Technical Reports Server (NTRS)
Greenisen, Michael C.
1987-01-01
The STS Space Suited and unsuited dominant upper limb performance was evaluated in order to quantify future EVA astronaut skeletal muscle upper limb performance expectations. Testing was performed with subjects standing in EVA STS foot restraints. Data was collected with a CYBEX Dynamometer enclosed in a waterproof container. Control data was taken in one g. During one g testing, weight of the Space Suit was relieved from the subject via an overhead crane with a special connection to the PLSS of the suit. Experimental data was acquired during simulated zero g, accomplished by neutral buoyancy in the Weightless Environment Training Facility. Unsuited subjects became neutrally buoyant via SCUBA BC vests. Actual zero g experimental data was collected during parabolic arc flights on board NASA's modified KC-135 aircraft. During all test conditions, subjects performed five EVA work tasks requiring dominant upper limb performance and ten individual joint articulation movements. Dynamometer velocities for each tested movement were 0 deg/sec, 30 or 60 deg/sec and 120 or 180 deg/sec, depending on the test, with three repetitions per test. Performance was measured in foot pounds of torque.
Electric vehicle chassis dynamometer test methods at JPL and their correlation to track tests
NASA Technical Reports Server (NTRS)
Marte, J.; Bryant, J.
1983-01-01
Early in its electric vehicle (EV) test program, JPL recognized that EV test procedures were too vague and too loosely defined to permit much meaningful data to be obtained from the testing. Therefore, JPL adopted more stringent test procedures and chose the chassis dynamometer rather than the track as its principal test technique. Through the years, test procedures continued to evolve towards a methodology based on chassis dynamometers which would exhibit good correlation with track testing. Based on comparative dynamometer and track test results on the ETV-1 vehicle, the test methods discussed in this report demonstrate a means by which excellent track-to-dynamometer correlation can be obtained.
2011-03-01
input spindle from the engine to over tighten and apply an even greater amount of resistance to the engine shaft . Not only was this dangerous to...Mengistu, Todd Rotramel, and Matt Rippl, all of whom worked together with me to design and build the test rig for our dynamometer setup. Countless...hours were spent together planning and executing the design and building the stand itself. The AFIT machine shop crew and ENY lab techs also
40 CFR 610.61 - Engine dynamometer tests.
Code of Federal Regulations, 2010 CFR
2010-07-01
... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...
40 CFR 610.61 - Engine dynamometer tests.
Code of Federal Regulations, 2013 CFR
2013-07-01
... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...
40 CFR 610.61 - Engine dynamometer tests.
Code of Federal Regulations, 2012 CFR
2012-07-01
... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...
40 CFR 610.61 - Engine dynamometer tests.
Code of Federal Regulations, 2011 CFR
2011-07-01
... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...
40 CFR 610.61 - Engine dynamometer tests.
Code of Federal Regulations, 2014 CFR
2014-07-01
... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...
Yu, Ruby; Ong, Sherlin; Cheung, Osbert; Leung, Jason; Woo, Jean
2017-06-01
The objectives of this study were to update the reference values of grip strength, to estimate the prevalence of low grip strength, and to examine the impact of different aspects of measurement protocol on grip strength values in Chinese adults. A cross-sectional survey of Chinese men (n = 714) and women (n = 4014) aged 18-102 years was undertaken in different community settings in Hong Kong. Grip strength was measured with a digital dynamometer (TKK 5401 Grip-D; Takei, Niigata, Japan). Low grip strength was defined as grip strength 2 standard deviations or more below the mean for young adults. The effects of measurement protocol on grip strength values were examined in a subsample of 45 men and women with repeated measures of grip strength taken with a hydraulic dynamometer (Baseline; Fabrication Enterprises Inc, Irvington, NY), using pair t-tests, intraclass correlation coefficient, and Bland and Altman plots. Grip strength was greater among men than among women (P < .001) and the rate of decline differed between sexes (P < .001). The prevalence of low grip strength also increased with age, reaching a rate of 16.5% in men and 20.6% in women aged 65+. Although the TKK digital dynamometer gave higher grip strength values than the Baseline hydraulic dynamometer (P < .001), the degree of agreement between the 2 dynamometers was satisfactory. Higher grip strength values were also observed when the measurement was performed with the elbow extended in a standing position, compared with that with the elbow flexed at 90° in a sitting position, using the same dynamometer (P < .05). This study updated the reference values of grip strength and estimated the prevalence of low grip strength among Chinese adults spanning a wide age range. These findings might be useful for risk estimation and evaluation of interventions. However, grip strength measurements should be interpreted with caution, as grip strength values can be affected by type of dynamometer used, assessment posture, and elbow position. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Oldrieve, R. E.
1971-01-01
Fourteen materials were evaluated in engine screening tests on full-size thermal reactors for automobile engine pollution control systems. Cyclic test-stand engine operation provided 2 hours at 1040 C and a 20-minute air-cool to 70 C each test cycle. Each reactor material was exposed to 83 cycles in 200 hours of engine testing. On the basis of resistance to oxidation and distortion, the best materials included two ferritic iron alloys (Ge 1541 and Armco 18S/R), several commercial oxidation-resistant coatings on AlSl 651 (19-9 DL), and possibly uncoated AISI 310. The best commercial coatings were Cr-Al, Ni-Cr, and a glass ceramic.
40 CFR 86.208-94 - Dynamometer.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Passenger Vehicles; Cold Temperature Test Procedures § 86.208-94 Dynamometer. (a) For testing that is... the manufacturer, a dynamometer with different characteristics may be used provided cold CO emissions...
40 CFR 86.208-94 - Dynamometer.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Passenger Vehicles; Cold Temperature Test Procedures § 86.208-94 Dynamometer. (a) For testing that is... the manufacturer, a dynamometer with different characteristics may be used provided cold CO emissions...
40 CFR 86.208-94 - Dynamometer.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Passenger Vehicles; Cold Temperature Test Procedures § 86.208-94 Dynamometer. (a) For testing that is... the manufacturer, a dynamometer with different characteristics may be used provided cold CO emissions...
[Research and workshop on alternative fuels for aviation. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1999-09-01
The Renewable Aviation Fuels Development Center (RAFDC) at Baylor University was granted U. S. Department of Energy (US DOE) and Federal Aviation Administration (FAA) funds for research and development to improve the efficiency in ethanol powered aircraft, measure performance and compare emissions of ethanol, Ethyl Tertiary Butyl Ether (ETBE) and 100 LL aviation gasoline. The premise of the initial proposal was to use a test stand owned by Engine Components Inc. (ECI) based in San Antonio, Texas. After the grant was awarded, ECI decided to close down its test stand facility. Since there were no other test stands available atmore » that time, RAFDC was forced to find additional support to build its own test stand. Baylor University provided initial funds for the test stand building. Other obstacles had to be overcome in order to initiate the program. The price of the emission testing equipment had increased substantially beyond the initial quote. Rosemount Analytical Inc. gave RAFDC an estimate of $120,000.00 for a basic emission testing package. RAFDC had to find additional funding to purchase this equipment. The electronic ignition unit also presented a series of time consuming problems. Since at that time there were no off-the-shelf units of this type available, one had to be specially ordered and developed. FAA funds were used to purchase a Super Flow dynamometer. Due to the many unforeseen obstacles, much more time and effort than originally anticipated had to be dedicated to the project, with much of the work done on a volunteer basis. Many people contributed their time to the program. One person, mainly responsible for the initial design of the test stand, was a retired engineer from Allison with extensive aircraft engine test stand experience. Also, many Baylor students volunteered to assemble the. test stand and continue to be involved in the current test program. Although the program presented many challenges, which resulted in delays, the RAFDC's test stand is an asset which provides an ongoing research capability dedicated to the testing of alternative fuels for aircraft engines. The test stand is now entirely functional with the exception of the electronic ignition unit which still needs adjustments.« less
40 CFR 86.137-90 - Dynamometer test run, gaseous and particulate emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... filters to the weighing chamber for post-test conditioning, if applicable. (22) Disconnect the exhaust... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Dynamometer test run, gaseous and... New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.137-90 Dynamometer test run, gaseous...
40 CFR 86.137-90 - Dynamometer test run, gaseous and particulate emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... filters to the weighing chamber for post-test conditioning, if applicable. (22) Disconnect the exhaust... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Dynamometer test run, gaseous and... New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.137-90 Dynamometer test run, gaseous...
40 CFR 86.137-90 - Dynamometer test run, gaseous and particulate emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... filters to the weighing chamber for post-test conditioning, if applicable. (22) Disconnect the exhaust... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Dynamometer test run, gaseous and... New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.137-90 Dynamometer test run, gaseous...
40 CFR 86.137-90 - Dynamometer test run, gaseous and particulate emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... filters to the weighing chamber for post-test conditioning, if applicable. (22) Disconnect the exhaust... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Dynamometer test run, gaseous and... New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.137-90 Dynamometer test run, gaseous...
40 CFR 86.137-94 - Dynamometer test run, gaseous and particulate emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... filters to the weighing chamber for post-test conditioning, if applicable. (22) Disconnect the exhaust... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Dynamometer test run, gaseous and... New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.137-94 Dynamometer test run, gaseous...
40 CFR 86.1334-84 - Pre-test engine and dynamometer preparation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Pre-test engine and dynamometer preparation. 86.1334-84 Section 86.1334-84 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Exhaust Test Procedures § 86.1334-84 Pre-test engine and dynamometer preparation. (a) Control system...
40 CFR 86.1334-84 - Pre-test engine and dynamometer preparation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Pre-test engine and dynamometer preparation. 86.1334-84 Section 86.1334-84 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Exhaust Test Procedures § 86.1334-84 Pre-test engine and dynamometer preparation. (a) Control system...
40 CFR 86.1334-84 - Pre-test engine and dynamometer preparation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Pre-test engine and dynamometer preparation. 86.1334-84 Section 86.1334-84 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Exhaust Test Procedures § 86.1334-84 Pre-test engine and dynamometer preparation. (a) Control system...
40 CFR 86.1334-84 - Pre-test engine and dynamometer preparation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Pre-test engine and dynamometer preparation. 86.1334-84 Section 86.1334-84 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Exhaust Test Procedures § 86.1334-84 Pre-test engine and dynamometer preparation. (a) Control system...
A comparison of different vibration exercise techniques on neuromuscular performance.
García-Gutiérrez, M T; Rhea, M R; Marín, P J
2014-09-01
The first purpose of this study was to determine the effects of whole-body vibration (WBV) exercise during an isometric hand-grip exercise. The second purpose was to evaluate whether more than one vibratory focus would evoke an increase in the effects evoked by only one vibratory focus. The present study investigated whether WBV exposure during 10 repetitions of a handgrip dynamometer while standing on a WBV platform. Twenty-eight recreationally active university students completed 3 different test conditions, in random order: 1) grip dynamometer exercise with superimposed WBV and contralateral arm vibration (WBV+AV); 2) superimposed arm vibration only (AV); 3) grip dynamometer exercise without vibration (Control). The hand grip strength was slightly higher in the WBV condition as compared to the Control and AV conditions (1.1% and 3.6%, p>0.05, respectively). A main effect of the EMGrms of extensor digitorum muscle (ED) was observed indicating that the WBV+AV condition produced a lower co-activation of ED during a flexor digital task than the Control and AV (p<0.05) conditions. The application of WBV+AV may acutely increase muscle coordination and decreases the coactivation of ED. Furthermore, the muscle EMGrms showed increases in activation near the vibratory focus in both upper- and lower-body.
Hardware-in-the-Loop Testing of Utility-Scale Wind Turbine Generators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schkoda, Ryan; Fox, Curtiss; Hadidi, Ramtin
2016-01-26
Historically, wind turbine prototypes were tested in the field, which was--and continues to be--a slow and expensive process. As a result, wind turbine dynamometer facilities were developed to provide a more cost-effective alternative to field testing. New turbine designs were tested and the design models were validated using dynamometers to drive the turbines in a controlled environment. Over the years, both wind turbine dynamometer testing and computer technology have matured and improved, and the two are now being joined to provide hardware-in-the-loop (HIL) testing. This type of testing uses a computer to simulate the items that are missing from amore » dynamometer test, such as grid stiffness, voltage, frequency, rotor, and hub. Furthermore, wind input and changing electric grid conditions can now be simulated in real time. This recent advance has greatly increased the utility of dynamometer testing for the development of wind turbine systems.« less
40 CFR 86.135-12 - Dynamometer procedure.
Code of Federal Regulations, 2013 CFR
2013-07-01
... control of pre-selectable power settings may be set anytime prior to the beginning of the emissions test... Heavy-Duty Vehicles; Test Procedures § 86.135-12 Dynamometer procedure. (a) Overview. The dynamometer run consists of two tests, a “cold” start test, after a minimum 12-hour and a maximum 36-hour soak...
40 CFR 86.135-12 - Dynamometer procedure.
Code of Federal Regulations, 2014 CFR
2014-07-01
... control of pre-selectable power settings may be set anytime prior to the beginning of the emissions test... Heavy-Duty Vehicles; Test Procedures § 86.135-12 Dynamometer procedure. (a) Overview. The dynamometer run consists of two tests, a “cold” start test, after a minimum 12-hour and a maximum 36-hour soak...
40 CFR 86.137-96 - Dynamometer test run, gaseous and particulate emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Dynamometer test run, gaseous and particulate emissions. 86.137-96 Section 86.137-96 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.137-96 Dynamometer test run, gaseous...
40 CFR 86.137-96 - Dynamometer test run, gaseous and particulate emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Dynamometer test run, gaseous and particulate emissions. 86.137-96 Section 86.137-96 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.137-96 Dynamometer test run, gaseous...
40 CFR 1066.410 - Dynamometer test procedure.
Code of Federal Regulations, 2014 CFR
2014-07-01
... drive mode. (For purposes of this paragraph (g), the term four-wheel drive includes other multiple drive... Dynamometer test procedure. (a) Dynamometer testing may consist of multiple drive cycles with both cold-start...-setting part identifies the driving schedules and the associated sample intervals, soak periods, engine...
40 CFR 1066.201 - Dynamometer overview.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Dynamometer overview. 1066.201 Section 1066.201 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.201 Dynamometer overview. This subpart...
40 CFR 86.135-12 - Dynamometer procedure.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Heavy-Duty Vehicles; Test Procedures § 86.135-12 Dynamometer procedure. (a) Overview. The dynamometer run consists of two tests, a “cold” start test, after a minimum 12-hour and a maximum 36-hour soak according to the provisions of §§ 86.132 and 86.133, and a “hot” start test following the “cold” start by 10...
40 CFR 86.135-12 - Dynamometer procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Heavy-Duty Vehicles; Test Procedures § 86.135-12 Dynamometer procedure. (a) Overview. The dynamometer run consists of two tests, a “cold” start test, after a minimum 12-hour and a maximum 36-hour soak according to the provisions of §§ 86.132 and 86.133, and a “hot” start test following the “cold” start by 10...
40 CFR 86.135-12 - Dynamometer procedure.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Heavy-Duty Vehicles; Test Procedures § 86.135-12 Dynamometer procedure. (a) Overview. The dynamometer run consists of two tests, a “cold” start test, after a minimum 12-hour and a maximum 36-hour soak according to the provisions of §§ 86.132 and 86.133, and a “hot” start test following the “cold” start by 10...
40 CFR 1066.275 - Daily dynamometer readiness verification.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.275 Daily... automated process for this verification procedure, perform this evaluation by setting the initial speed and... your dynamometer does not perform this verification with an automated process: (1) With the dynamometer...
40 CFR 1066.215 - Summary of verification procedures for chassis dynamometers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.215 Summary... judgment. (c) Automated dynamometer verifications and calibrations. In some cases, dynamometers are... specified in this subpart. You may use these automated functions instead of following the procedures we...
TTI (Texas Transportation Institute) track/dynamometer study. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reineman, M.; Thompson, G.
1983-01-01
Seven passenger cars and one light truck were operated over the EPA urban and highway driving cycles to compare fuel economy measurements obtained on a test track with the fuel economy results obtained on a chassis dynamometer. The test program was designed to duplicate, as closely as possible, the track force loading (as determined by standard EPA road coastdown procedures) on the dynamometer. Experimental parameters which were investigated included loading differences between front- and rear-wheel drive vehicles, volumetric versus carbon balance fuel measurement techniques, coupled versus uncoupled roll dynamometer tests, and curved track versus straight track coastdowns.
40 CFR 86.884-7 - Dynamometer operation cycle for smoke emission tests.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Dynamometer operation cycle for smoke... Dynamometer operation cycle for smoke emission tests. (a) The following sequence of operations shall be... the preconditioning prior to the smoke cycle. (ii) With the throttle remaining in the fully open...
40 CFR 86.118-78 - Dynamometer calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... test speed range. The device used to drive the dynamometer is then disengaged from the dynamometer and the roll(s) is (are) allowed to coast down. The kinetic energy of the system is dissipated by the... vehicle. The inertia of the free (rear) roll may be neglected in the case of dynamometers with paired...
40 CFR 86.118-78 - Dynamometer calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... test speed range. The device used to drive the dynamometer is then disengaged from the dynamometer and the roll(s) is (are) allowed to coast down. The kinetic energy of the system is dissipated by the... vehicle. The inertia of the free (rear) roll may be neglected in the case of dynamometers with paired...
40 CFR 86.118-78 - Dynamometer calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... test speed range. The device used to drive the dynamometer is then disengaged from the dynamometer and the roll(s) is (are) allowed to coast down. The kinetic energy of the system is dissipated by the... vehicle. The inertia of the free (rear) roll may be neglected in the case of dynamometers with paired...
40 CFR 86.118-78 - Dynamometer calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... test speed range. The device used to drive the dynamometer is then disengaged from the dynamometer and the roll(s) is (are) allowed to coast down. The kinetic energy of the system is dissipated by the... vehicle. The inertia of the free (rear) roll may be neglected in the case of dynamometers with paired...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wallen, Robert B; Lambert, Scott R; Gevorgian, Vahan
This report details the commissioning of the 5-megawatt dynamometer at the National Wind Technology Center at the National Renewable Energy Laboratory. The purpose of these characterization tests were to verify the dynamometer's performance over the widest possible range of operating conditions, gain insight into system-level behavior, and establish confidence in measurement data.
NASA Technical Reports Server (NTRS)
Mcardle, Jack G.
1986-01-01
A variable inlet guide van (VIGV) type convertible engine that could be used to power future high-speed rotorcraft was tested on an outdoor stand. The engine ran stably and smoothly in the turbofan, turboshaft, and dual (combined fan and shaft) power modes. In the turbofan mode with the VIGV open fuel consumption was comparable to that of a conventional turbofan engine. In the turboshaft mode with the VIGV closed fuel consumption was higher than that of present turboshaft engines because power was wasted in churning fan-tip airflow. In dynamic performance tests with a specially built digital engine control and using a waterbrake dynamometer for shaft load, the engine responded effectively to large steps in thrust command and shaft torque. Previous mission analyses of a conceptual X-wing rotorcraft capable of 400-knot cruise speed were revised to account for more fan-tip churning power loss than was originally estimated. The new calculations confirm that using convertible engines rather than separate lift and cruise engines would result in a smaller, lighter craft with lower fuel use and direct operating cost.
40 CFR 1066.215 - Summary of verification and calibration procedures for chassis dynamometers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer... manufacturer instructions and good engineering judgment. (c) Automated dynamometer verifications and... accomplish the verifications and calibrations specified in this subpart. You may use these automated...
40 CFR 1066.215 - Summary of verification and calibration procedures for chassis dynamometers.
Code of Federal Regulations, 2013 CFR
2013-07-01
... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer... manufacturer instructions and good engineering judgment. (c) Automated dynamometer verifications and... accomplish the verifications and calibrations specified in this subpart. You may use these automated...
Space fabrication demonstration system. [beam builder and induction fastening
NASA Technical Reports Server (NTRS)
1980-01-01
The development effort on the composite beam cap fabricator was completed within cost and close to abbreviated goals. The design and analysis of flight weight primary and secondary beam builder structures proceeded satisfactorily but remains curtailed until further funding is made available to complete the work. The induction fastening effort remains within cost and schedule constraints. Tests of the LARC prototype induction welder is continuing in an instrumented test stand comprised of a Dumore drill press (air over oil feed for variable applied loads) and a dynamometer to measure actual welding loads. Continued testing shows that the interface screening must be well impregnated with resin to ensure proper flow when bonding graphite-acrylic lap shear samples. Specimens prepared from 0.030 inch thick graphite-polyethersulfone are also available for future induction fastening evaluation.
The DOE ETV-1 Electric Test Vehicle. Phase 3: Performance Testing and system evaluation
NASA Technical Reports Server (NTRS)
Kurtz, D.
1981-01-01
Engineering tests were conducted in order to characterize overall system performance and component efficiencies within the system environment. A dynamometer was used in order to minimize the ambient effects and large uncertainties present in track testing. Extensive test requirements were defined and procedures were carefully controlled in order to maintain a high degree of credibility. Limited track testing was performed in order to corroborate the dynamometer results. Test results include an energy flow analysis through the major subsystems and incorporate the aerodynamic and rolling losses under cyclic and various steady speed conditions. The major output from all relevant dynamometer and track tests is also included.
National Wind Technology Center Dynamic 5-Megawatt Dynamometer
Felker, Fort
2018-06-06
The National Wind Technology Center (NWTC) offers wind industry engineers a unique opportunity to conduct a wide range of tests. Its custom-designed dynamometers can test wind turbine systems from 1 kilowatt (kW) to 5 megawatts (MW). The NWTC's new dynamometer facility simulates operating field conditions to assess the reliability and performance of wind turbine prototypes and commercial machines, thereby reducing deployment time, failures, and maintenance or replacement costs. Funded by the U.S. Department of Energy with American Recovery and Reinvestment Act (ARRA) funds, the 5-MW dynamometer will provide the ability to test wind turbine drivetrains and connect those drivetrains directly to the electricity grid or through a controllable grid interface (CGI). The CGI tests the low-voltage ride-through capability of a drivetrain as well as its response to faults and other abnormal grid conditions.
40 CFR 1066.270 - Unloaded coastdown verification.
Code of Federal Regulations, 2013 CFR
2013-07-01
... manufacturer. (2) With the dynamometer in coastdown mode, set the dynamometer inertia for the smallest vehicle... with the dynamometer inertia set for the largest vehicle weight that you expect to test. (4) Determine the average coastdown force, F, for each speed and inertia setting using the following equation...
40 CFR 1066.270 - Unloaded coastdown verification.
Code of Federal Regulations, 2012 CFR
2012-07-01
... manufacturer. (2) With the dynamometer in coastdown mode, set the dynamometer inertia for the smallest vehicle... with the dynamometer inertia set for the largest vehicle weight that you expect to test. (4) Determine the average coastdown force, F, for each speed and inertia setting using the following equation...
40 CFR 86.1218-85 - Dynamometer calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... the power absorption unit. The dynamometer is driven above the test speed range. The device used to... coastdown. The kinetic energy of the system is dissipated by the dynamometer. This method neglects the... with paired rolls, the inertia and power absorption of the free (rear) roll may be neglected if its...
40 CFR 86.1218-85 - Dynamometer calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the power absorption unit. The dynamometer is driven above the test speed range. The device used to... coastdown. The kinetic energy of the system is dissipated by the dynamometer. This method neglects the... with paired rolls, the inertia and power absorption of the free (rear) roll may be neglected if its...
40 CFR 86.1218-85 - Dynamometer calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... the power absorption unit. The dynamometer is driven above the test speed range. The device used to... coastdown. The kinetic energy of the system is dissipated by the dynamometer. This method neglects the... with paired rolls, the inertia and power absorption of the free (rear) roll may be neglected if its...
40 CFR 86.1218-85 - Dynamometer calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the power absorption unit. The dynamometer is driven above the test speed range. The device used to... coastdown. The kinetic energy of the system is dissipated by the dynamometer. This method neglects the... with paired rolls, the inertia and power absorption of the free (rear) roll may be neglected if its...
40 CFR 86.215-94 - EPA urban dynamometer driving schedule.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 18 2011-07-01 2011-07-01 false EPA urban dynamometer driving schedule. 86.215-94 Section 86.215-94 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.215-94 EPA urban dynamometer...
40 CFR 86.118-00 - Dynamometer calibrations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1977 and Later Model Year New Light-Duty Vehicles and New Light-Duty Trucks and New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.118-00 Dynamometer calibrations. (a) The dynamometer shall be...
40 CFR 86.118-00 - Dynamometer calibrations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1977 and Later Model Year New Light-Duty Vehicles and New Light-Duty Trucks and New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.118-00 Dynamometer calibrations. (a) The dynamometer shall be...
40 CFR 1066.235 - Speed verification procedure.
Code of Federal Regulations, 2012 CFR
2012-07-01
... before testing, and after major maintenance. (c) Procedure. Use one of the following procedures to verify... dynamometer control circuits. Determine the speed error as follows: (i) Set the dynamometer to speed-control mode. Set the dynamometer speed to a value between 4.2 m/s and the maximum speed expected during...
40 CFR 90.306 - Dynamometer torque cell calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Dynamometer torque cell calibration... Emission Test Equipment Provisions § 90.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used...-cell or transfer standard may be used to verify the torque measurement system. (1) The master load-cell...
40 CFR 90.306 - Dynamometer torque cell calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Dynamometer torque cell calibration... Emission Test Equipment Provisions § 90.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used...-cell or transfer standard may be used to verify the torque measurement system. (1) The master load-cell...
40 CFR 90.306 - Dynamometer torque cell calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Dynamometer torque cell calibration... Emission Test Equipment Provisions § 90.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used...-cell or transfer standard may be used to verify the torque measurement system. (1) The master load-cell...
40 CFR 90.306 - Dynamometer torque cell calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Dynamometer torque cell calibration... Emission Test Equipment Provisions § 90.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used...-cell or transfer standard may be used to verify the torque measurement system. (1) The master load-cell...
The Direct Measurement of Engine Power on an Airplane in Flight with a Hub Type Dynamometer
NASA Technical Reports Server (NTRS)
Gove, W D; Green, M W
1927-01-01
This report describes tests made to obtain direct measurements of engine power in flight. Tests were made with a Bendemann hub dynamometer installed on a modified DH-4 Airplane, Liberty 12 Engine, to determine the suitability of this apparatus. This dynamometer unit, which was designed specially for use with a liberty 12 engine, is a special propeller hub in which is incorporated a system of pistons and cylinders interposed between the propeller and the engine crankshaft. The torque and thrust forces are balanced by fluid pressures, which are recorded by instruments in the cockpit. These tests have shown the suitability of this type of hub dynamometer for measurement of power in flight and for the determination of the torque and power coefficients of the propeller. (author)
Pua, Yong-Hao; Liang, Zhiqi; Ong, Peck-Hoon; Bryant, Adam L; Lo, Ngai-Nung; Clark, Ross A
2011-12-01
Knee extensor strength is an important correlate of physical function in patients with knee osteoarthritis; however, it remains unclear whether standing balance is also a correlate. The purpose of this study was to evaluate the cross-sectional associations of knee extensor strength, standing balance, and their interaction with physical function. One hundred four older adults with end-stage knee osteoarthritis awaiting a total knee replacement (mean ± SD age 67 ± 8 years) participated. Isometric knee extensor strength was measured using an isokinetic dynamometer. Standing balance performance was measured by the center of pressure displacement during quiet standing on a balance board. Physical function was measured by the self-report Short Form 36 (SF-36) questionnaire and by the 10-meter fast-pace gait speed test. After adjustment for demographic and knee pain variables, we detected significant knee strength by standing balance interaction terms for both SF-36 physical function and fast-pace gait speed. Interrogation of the interaction revealed that standing balance in the anteroposterior plane was positively related to physical function among patients with lower knee extensor strength. Conversely, among patients with higher knee extensor strength, the standing balance-physical function associations were, or tended to be, negative. These findings suggest that although standing balance was related to physical function in patients with knee osteoarthritis, this relationship was complex and dependent on knee extensor strength level. These results are of importance in developing intervention strategies and refining theoretical models, but they call for further study. Copyright © 2011 by the American College of Rheumatology.
40 CFR 86.1237-85 - Dynamometer runs.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Dynamometer runs. 86.1237-85 Section... Methanol-Fueled Heavy-Duty Vehicles § 86.1237-85 Dynamometer runs. (a) The vehicle shall be either driven... the diurnal loss test and beginning of the hot soak preparation run shall not exceed 3 minutes, and...
Highway Vehicle Retrofit Evaluation : Phase 2. Report. Testing and Final Evaluation Results.
DOT National Transportation Integrated Search
1976-11-01
This report presents the results of engine dynamometer and vehicle chassis dynamometer tests conducted with selected automotive retrofit devices in the classes of ultrasonic carburetors, high-velocity intake manifolds, tuned exhaust systems, and high...
40 CFR 91.409 - Engine dynamometer test run.
Code of Federal Regulations, 2014 CFR
2014-07-01
... all pre-test data specified in § 91.405(c). (4) Start the test cycle (see § 91.410) within 10 minutes... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine dynamometer test run. 91.409... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.409...
40 CFR 91.409 - Engine dynamometer test run.
Code of Federal Regulations, 2010 CFR
2010-07-01
... all pre-test data specified in § 91.405(c). (4) Start the test cycle (see § 91.410) within 10 minutes... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine dynamometer test run. 91.409... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.409...
40 CFR 89.407 - Engine dynamometer test run.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Perform the pre-test procedure as specified in § 89.406. (3) Read and record the general test data as... (c)(5)(i) through (iii) of this section. (6) Read and record all pre-test data specified in § 89.405... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine dynamometer test run. 89.407...
40 CFR 91.409 - Engine dynamometer test run.
Code of Federal Regulations, 2013 CFR
2013-07-01
... all pre-test data specified in § 91.405(c). (4) Start the test cycle (see § 91.410) within 10 minutes... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine dynamometer test run. 91.409... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.409...
40 CFR 89.407 - Engine dynamometer test run.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Perform the pre-test procedure as specified in § 89.406. (3) Read and record the general test data as... (c)(5)(i) through (iii) of this section. (6) Read and record all pre-test data specified in § 89.405... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine dynamometer test run. 89.407...
40 CFR 91.409 - Engine dynamometer test run.
Code of Federal Regulations, 2012 CFR
2012-07-01
... all pre-test data specified in § 91.405(c). (4) Start the test cycle (see § 91.410) within 10 minutes... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine dynamometer test run. 91.409... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.409...
40 CFR 89.407 - Engine dynamometer test run.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Perform the pre-test procedure as specified in § 89.406. (3) Read and record the general test data as... (c)(5)(i) through (iii) of this section. (6) Read and record all pre-test data specified in § 89.405... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine dynamometer test run. 89.407...
40 CFR 91.409 - Engine dynamometer test run.
Code of Federal Regulations, 2011 CFR
2011-07-01
... all pre-test data specified in § 91.405(c). (4) Start the test cycle (see § 91.410) within 10 minutes... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine dynamometer test run. 91.409... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.409...
40 CFR 89.407 - Engine dynamometer test run.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Perform the pre-test procedure as specified in § 89.406. (3) Read and record the general test data as... (c)(5)(i) through (iii) of this section. (6) Read and record all pre-test data specified in § 89.405... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine dynamometer test run. 89.407...
40 CFR 89.407 - Engine dynamometer test run.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Perform the pre-test procedure as specified in § 89.406. (3) Read and record the general test data as... (c)(5)(i) through (iii) of this section. (6) Read and record all pre-test data specified in § 89.405... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine dynamometer test run. 89.407...
40 CFR 86.884-7 - Dynamometer operation cycle for smoke emission tests.
Code of Federal Regulations, 2014 CFR
2014-07-01
... provide the speed and load necessary to comply with the heavy-duty “curb idle” definition per § 86.084-2..., and held in, the fully open position. The inertia of the engine and the dynamometer, or alternately a... mode, motoring assist may be used to offset excessive dynamometer inertia load when necessary. No...
40 CFR 86.884-7 - Dynamometer operation cycle for smoke emission tests.
Code of Federal Regulations, 2012 CFR
2012-07-01
... be set to provide the speed and load necessary to comply with the heavy-duty “curb idle” definition..., and held in, the fully open position. The inertia of the engine and the dynamometer, or alternately a... mode, motoring assist may be used to offset excessive dynamometer inertia load when necessary. No...
40 CFR 86.884-7 - Dynamometer operation cycle for smoke emission tests.
Code of Federal Regulations, 2013 CFR
2013-07-01
... be set to provide the speed and load necessary to comply with the heavy-duty “curb idle” definition..., and held in, the fully open position. The inertia of the engine and the dynamometer, or alternately a... mode, motoring assist may be used to offset excessive dynamometer inertia load when necessary. No...
40 CFR 86.884-7 - Dynamometer operation cycle for smoke emission tests.
Code of Federal Regulations, 2011 CFR
2011-07-01
... be set to provide the speed and load necessary to comply with the heavy-duty “curb idle” definition..., and held in, the fully open position. The inertia of the engine and the dynamometer, or alternately a... mode, motoring assist may be used to offset excessive dynamometer inertia load when necessary. No...
40 CFR 86.341-79 - Diesel engine dynamometer test run.
Code of Federal Regulations, 2012 CFR
2012-07-01
... and sample probes as required; (2) Observe pre-test procedure, § 86.339; (3) Read and record the... observed torque for the rated and intermediate speeds; (8) Read and record all pre-test data specified in... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Diesel engine dynamometer test run. 86...
40 CFR 86.341-79 - Diesel engine dynamometer test run.
Code of Federal Regulations, 2013 CFR
2013-07-01
... and sample probes as required; (2) Observe pre-test procedure, § 86.339; (3) Read and record the... observed torque for the rated and intermediate speeds; (8) Read and record all pre-test data specified in... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Diesel engine dynamometer test run. 86...
40 CFR 86.341-79 - Diesel engine dynamometer test run.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and sample probes as required; (2) Observe pre-test procedure, § 86.339; (3) Read and record the... observed torque for the rated and intermediate speeds; (8) Read and record all pre-test data specified in... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Diesel engine dynamometer test run. 86...
40 CFR 86.341-79 - Diesel engine dynamometer test run.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and sample probes as required; (2) Observe pre-test procedure, § 86.339; (3) Read and record the... observed torque for the rated and intermediate speeds; (8) Read and record all pre-test data specified in... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Diesel engine dynamometer test run. 86...
Renewable Fuels and Lubricants Laboratory | Transportation Research | NREL
delivery vans to full-size buses and Class 8 tractors. Heavy-Duty and Light-Duty Engine Dynamometer Test Cells The ReFUEL Laboratory features two engine dynamometer test cells-one for heavy-duty (up to 600 hp the Heavy-Duty Federal Test Procedures (HD-FTP), are highly standardized, and results can be readily
40 CFR 86.131-00 - Vehicle preparation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... test dynamometer. This signal provides the input information that controls dynamometer dynamic inertia... implement dynamic inertia adjustments for a portion or all of their product line, this requirement is not...
Dyna Soars: Low Torque Measurement Dynamometer
ERIC Educational Resources Information Center
Dolph, Darrel A.
2004-01-01
Students in the Electronics Engineering Technology program at Pennsylvania College of Technology designed and built a computerized dynamometer platform for testing dc brushless motors. As the capstone experience for EET-320, Measurement and Tests course, students were divided into teams of four and were given three weeks to complete the project.…
40 CFR 86.208-94 - Dynamometer.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.208-94 Dynamometer. (a) For testing that is...
40 CFR 86.237-94 - Dynamometer test run, gaseous emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.237-94 Dynamometer...
Güçlüöver, A; Kutlu, M; Ciğerci, A E; Esen, H T; Demirkan, E; Erdoğdu, M
2015-11-01
In this study the Sport Experts ™ brand of hand grip dynamometer, measuring the continuity of force with the new developed load cell technology, was compared with Takei and Baseline® dynamometers, the current in use. It was tried to determine the correlation between them. In a study with provides use of clinical, orthopedic and rehabilitative purposes in the athletes and patient populations, this developed dynamometer can provide useful data by observing the continuity of force. The sample of the study included 60 badminton players in 2010-2011; consisting of Turkish Junior National male players (N.=16, age: 16.8±1.5), Junior National female players (N.=14, age: 16.9±1.6), amateur level male players (N.=15, age: 16.3±0.8) and amateur level female players (N.=15, age: 16.1±0.6). ANOVA was used in the statistical methods in order to compare the hand grip strength made by different brands; Pearson's correlation coefficient was used to determine the relationship level between dynamometers. Furthermore, test-retest reliability analysis was completed the new developed expert dynamometer. There was no statistically significant difference in the comparison of the dynamometers (P>0.05). Besides, a highly significant relationship (r=0.95 to 0.96) was found among all three dynamometers. However, the reliability coefficient was found (Chronbachs α: 0.989, ICC:0.97, r=0.97), (P<0.01) for the new developed expert dynamometer. Comparison between the dynamometers and the statistical results obtained from the correlation relationships shows interchangeability of dynamometers. As a result, our observation of force continuity (progression) of the athlete and patient populations is thought to be important.
40 CFR 1066.410 - Dynamometer test procedure.
Code of Federal Regulations, 2012 CFR
2012-07-01
... configuration that allows for proper simulation of vehicle cooling during in-use operation, subject to our... simulation of the actual normal forces that the tire and dynamometer roll interface would see if a loaded...
40 CFR 1066.410 - Dynamometer test procedure.
Code of Federal Regulations, 2013 CFR
2013-07-01
... configuration that allows for proper simulation of vehicle cooling during in-use operation, subject to our... simulation of the actual normal forces that the tire and dynamometer roll interface would see if a loaded...
The Dynamometer Hub for the Testing Propellers and Engines During Flight
NASA Technical Reports Server (NTRS)
Enoch, O
1921-01-01
The need for a device to measure flight resistance, engine and propeller power, and efficiency during flight grew in proportion to the demand for increased flying capacity in military types of aircraft. Here, a dynamometer hub was inserted between the engine and the propeller. Taken as a whole, the tests that were conducted show that though the dynamometer is a sensitive instrument liable to numerous derangements, it is undeniably useful even in its present form, when handled with care and skill. Facilitating, as it does, the possibility of maintaining the fixed position of the engine, the blocking out of the weight effect when the plane is in the sloping position, and the possibility of taking direct measurements of force at the point of transmission, the dynamometer appears to be by far the best solution of the problem of a flying test bench, utilized as a hydraulic balance with the smallest possible measuring stroke and the least tendency to oscillation.
40 CFR 86.159-00 - Exhaust emission test procedures for US06 emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... from the dynamometer rolls shall be used. A speed vs. time recording, as evidence of dynamometer test... vehicle. In the case of vehicles with rear engine compartments (or if special designs make the above... appropriate throttle action to maintain the proper speed-time relationship, or to permit sampling system...
Dynamic calibration of a wheelchair dynamometer.
DiGiovine, C P; Cooper, R A; Boninger, M L
2001-01-01
The inertia and resistance of a wheelchair dynamometer must be determined in order to compare the results of one study to another, independent of the type of device used. The purpose of this study was to describe and implement a dynamic calibration test for characterizing the electro-mechanical properties of a dynamometer. The inertia, the viscous friction, the kinetic friction, the motor back-electromotive force constant, and the motor constant were calculated using three different methods. The methodology based on a dynamic calibration test along with a nonlinear regression analysis produced the best results. The coefficient of determination comparing the dynamometer model output to the measured angular velocity and torque was 0.999 for a ramp input and 0.989 for a sinusoidal input. The inertia and resistance were determined for the rollers and the wheelchair wheels. The calculation of the electro-mechanical parameters allows for the complete description of the propulsive torque produced by an individual, given only the angular velocity and acceleration. The measurement of the electro-mechanical properties of the dynamometer as well as the wheelchair/human system provides the information necessary to simulate real-world conditions.
40 CFR 92.106 - Equipment for loading the engine.
Code of Federal Regulations, 2010 CFR
2010-07-01
... settings except idle and dynamic brake; and (ii) Less accuracy and precision is allowed at idle and dynamic...) For engine testing using a dynamometer, the engine dynamometer system must be capable of controlling...
40 CFR 86.1337-96 - Engine dynamometer test run.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. For a single... sample is lost. A separate leak check is needed. A leak check of a filter assembly that has only one seal ring in contact with the filter media will not detect a leak when tested under vacuum. A pressure leak...
40 CFR 86.1337-96 - Engine dynamometer test run.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. For a single... sample is lost. A separate leak check is needed. A leak check of a filter assembly that has only one seal ring in contact with the filter media will not detect a leak when tested under vacuum. A pressure leak...
40 CFR 86.1337-96 - Engine dynamometer test run.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. For a single... sample is lost. A separate leak check is needed. A leak check of a filter assembly that has only one seal ring in contact with the filter media will not detect a leak when tested under vacuum. A pressure leak...
40 CFR 86.1337-96 - Engine dynamometer test run.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. For a single... sample is lost. A separate leak check is needed. A leak check of a filter assembly that has only one seal ring in contact with the filter media will not detect a leak when tested under vacuum. A pressure leak...
NREL-Prime Next-Generation Drivetrain Dynamometer Test Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keller, Jonathan; Erdman, Bill; Blodgett, Douglas
2016-08-01
Advances in wind turbine drivetrain technologies are necessary to improve reliability and reduce the cost of energy for land-based and offshore wind turbines. The NREL-Prime Next-Generation Drivetrain team developed a geared, medium-speed drivetrain that is lighter, more reliable and more efficient than existing designs. One of the objectives of Phase II of the project was to complete the detailed design, fabrication, and dynamometer testing of a 750 kilowatt (kW) drivetrain that includes the key gearbox innovations designed by Romax Technology and power converter innovations designed by DNV Kema Renewables. The purpose of this document is to summarize these tests completedmore » in NREL's National Wind Technology Center 2.5 megawatt (MW) dynamometer.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDade, Mark
2016-12-01
The Department of Energy/National Renewable Energy Laboratory (DOE/NREL) owns and operates a megawatt-scale dynamometer used for testing wind turbine drive trains up to 1.5 megawatt (MW) in rated capacity. At this time, this unit is the only unit of its type in the United States, available for use by the American Wind Industry. Currently this dynamometer is heavily backlogged and unavailable to provide testing needed by various wind industry members. DOE/NREL is in possession of two critical pieces of equipment that may be used to develop an alternative Dynamometer facility, but does not have the funds or other resources necessarymore » to develop such a facility. The Participant possesses complimentary facilities and infrastructure that when combined with the NREL equipment can create such a test facility. The Participant is also committed to expending funds to develop and operate such a facility to the subsequent benefit of the Wind Industry and DOE Wind Energy program. In exchange for DOE/NREL providing the critical equipment, the Participant will grant DOE/NREL a minimum of 90 days of testing time per year in the new facility while incurring no facilities fees.« less
Test plan for performance testing of the Eaton AC-3 electric vehicle
NASA Astrophysics Data System (ADS)
Crumley, R.; Heiselmann, H. W.
1985-04-01
An alternating current (ac) propulsion system for an electric vehicle was developed and tested. The test bed vehicle is a modified 1981 Mercury Lynx. The test plan was prepared specifically for the third modification to this test bed and identified as the Eaton AC-3. The scope of the testing done on the Eaton AC-3 includes coastdown and dynamometer tests but does not include environmental, on-road, or track testing. Coastdown testing is performed in accordance with SAE J-1263 (SAE Recommended Practice for Road Load Measurement and Dynamometer Simulation Using Coastdown Techniques).
Kim, Won Kuel; Seo, Kyung Mook; Kang, Si Hyun
2014-01-01
Objective To determine the reliability and validity of hand-held dynamometer (HHD) depending on its fixation in measuring isometric knee extensor strength by comparing the results with an isokinetic dynamometer. Methods Twenty-seven healthy female volunteers participated in this study. The subjects were tested in seated and supine position using three measurement methods: isometric knee extension by isokinetic dynamometer, non-fixed HHD, and fixed HHD. During the measurement, the knee joints of subjects were fixed at a 35° angle from the extended position. The fixed HHD measurement was conducted with the HHD fixed to distal tibia with a Velcro strap; non-fixed HHD was performed with a hand-held method without Velcro fixation. All the measurements were repeated three times and among them, the maximum values of peak torque were used for the analysis. Results The data from the fixed HHD method showed higher validity than the non-fixed method compared with the results of the isokinetic dynamometer. Pearson correlation coefficients (r) between fixed HHD and isokinetic dynamometer method were statistically significant (supine-right: r=0.806, p<0.05; seating-right: r=0.473, p<0.05; supine-left: r=0.524, p<0.05), whereas Pearson correlation coefficients between non-fixed dynamometer and isokinetic dynamometer methods were not statistically significant, except for the result of the supine position of the left leg (r=0.384, p<0.05). Both fixed and non-fixed HHD methods showed excellent inter-rater reliability. However, the fixed HHD method showed a higher reliability than the non-fixed HHD method by considering the intraclass correlation coefficient (fixed HHD, 0.952-0.984; non-fixed HHD, 0.940-0.963). Conclusion Fixation of HHD during measurement in the supine position increases the reliability and validity in measuring the quadriceps strength. PMID:24639931
40 CFR 85.2229 - Dynamometer-EPA 81.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Dynamometer-EPA 81. 85.2229 Section 85.2229 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED....2229 Dynamometer—EPA 81. (a) Applicability. The requirements of this subsection apply to short tests...
40 CFR 85.2229 - Dynamometer-EPA 81.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Dynamometer-EPA 81. 85.2229 Section 85.2229 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED....2229 Dynamometer—EPA 81. (a) Applicability. The requirements of this subsection apply to short tests...
40 CFR 85.2229 - Dynamometer-EPA 81.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Dynamometer-EPA 81. 85.2229 Section 85.2229 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED....2229 Dynamometer—EPA 81. (a) Applicability. The requirements of this subsection apply to short tests...
40 CFR 86.135-90 - Dynamometer procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and methanol-fueled Otto-cycle vehicles. The dynamometer run consists of two tests, a “cold” start... analyzed for hydrocarbon, carbon monoxide, carbon dioxide, and oxides of nitrogen. Methanol and formaldehyde samples (exhaust and dilution air) are collected and analyzed for methanol-fueled vehicles (a...
40 CFR 86.135-90 - Dynamometer procedure.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and methanol-fueled Otto-cycle vehicles. The dynamometer run consists of two tests, a “cold” start... analyzed for hydrocarbon, carbon monoxide, carbon dioxide, and oxides of nitrogen. Methanol and formaldehyde samples (exhaust and dilution air) are collected and analyzed for methanol-fueled vehicles (a...
40 CFR 1066.250 - Base inertia verification.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Base inertia verification. 1066.250... CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.250 Base inertia verification. (a) Overview. This section describes how to verify the dynamometer's base inertia. (b) Scope and frequency...
40 CFR 1066.250 - Base inertia verification.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Base inertia verification. 1066.250... CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.250 Base inertia verification. (a) Overview. This section describes how to verify the dynamometer's base inertia. (b) Scope and frequency...
40 CFR 1066.250 - Base inertia verification.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Base inertia verification. 1066.250... CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.250 Base inertia verification. (a) Overview. This section describes how to verify the dynamometer's base inertia. (b) Scope and frequency...
Silent Flange Coupling Design Used for the Schenck Eddy Current Dynamometer
NASA Astrophysics Data System (ADS)
Schinteie, D.; Croitorescu, V.
2016-11-01
The silent flange used for coupling different machines/systems to an eddy current dynamometer represents one of the modular components each test-bench should use. By introducing a silent flange into a dynamometer, the coupling steps are easier and faster. For an appropriate design, the silent flange was analyzed using dedicated software during different operation procedures and scenarios, for materials that allow easy manufacturing. This study shows that the design for this silent flange model has no danger of failure due to the small deformation and the values for the equivalent stresses. The silent flange coupling is suitable for the dynamometer for his high positioning accuracy, the zero backlash and the fact that there is no motion between the shafts.
Axial calibration methods of piezoelectric load sharing dynamometer
NASA Astrophysics Data System (ADS)
Zhang, Jun; Chang, Qingbing; Ren, Zongjin; Shao, Jun; Wang, Xinlei; Tian, Yu
2018-06-01
The relationship between input and output of load sharing dynamometer is seriously non-linear in different loading points of a plane, so it's significant for accutately measuring force to precisely calibrate the non-linear relationship. In this paper, firstly, based on piezoelectric load sharing dynamometer, calibration experiments of different loading points are performed in a plane. And then load sharing testing system is respectively calibrated based on BP algorithm and ELM (Extreme Learning Machine) algorithm. Finally, the results show that the calibration result of ELM is better than BP for calibrating the non-linear relationship between input and output of loading sharing dynamometer in the different loading points of a plane, which verifies that ELM algorithm is feasible in solving force non-linear measurement problem.
40 CFR 86.218-94 - Dynamometer calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.218-94 Dynamometer calibration. The...
40 CFR 86.1337-2007 - Engine dynamometer test run.
Code of Federal Regulations, 2012 CFR
2012-07-01
... engine, dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. (2..., loaded particulate sample filter cartridge into the filter holder assembly. It is recommended that this be done within the filter stabilization environment, with both ends of the filter holder assembly...
40 CFR 86.1337-2007 - Engine dynamometer test run.
Code of Federal Regulations, 2013 CFR
2013-07-01
... engine, dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. (2..., loaded particulate sample filter cartridge into the filter holder assembly. It is recommended that this be done within the filter stabilization environment, with both ends of the filter holder assembly...
40 CFR 86.1337-2007 - Engine dynamometer test run.
Code of Federal Regulations, 2010 CFR
2010-07-01
... engine, dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. (2..., loaded particulate sample filter cartridge into the filter holder assembly. It is recommended that this be done within the filter stabilization environment, with both ends of the filter holder assembly...
40 CFR 86.1337-2007 - Engine dynamometer test run.
Code of Federal Regulations, 2011 CFR
2011-07-01
... engine, dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. (2..., loaded particulate sample filter cartridge into the filter holder assembly. It is recommended that this be done within the filter stabilization environment, with both ends of the filter holder assembly...
Park, Hee-Won; Baek, Sora; Kim, Hong Young; Park, Jung-Gyoo; Kang, Eun Kyoung
2017-10-01
To investigate the reliability and validity of a new method for isometric back extensor strength measurement using a portable dynamometer. A chair equipped with a small portable dynamometer was designed (Power Track II Commander Muscle Tester). A total of 15 men (mean age, 34.8±7.5 years) and 15 women (mean age, 33.1±5.5 years) with no current back problems or previous history of back surgery were recruited. Subjects were asked to push the back of the chair while seated, and their isometric back extensor strength was measured by the portable dynamometer. Test-retest reliability was assessed with intraclass correlation coefficient (ICC). For the validity assessment, isometric back extensor strength of all subjects was measured by a widely used physical performance evaluation instrument, BTE PrimusRS system. The limit of agreement (LoA) from the Bland-Altman plot was evaluated between two methods. The test-retest reliability was excellent (ICC=0.82; 95% confidence interval, 0.65-0.91). The Bland-Altman plots demonstrated acceptable agreement between the two methods: the lower 95% LoA was -63.1 N and the upper 95% LoA was 61.1 N. This study shows that isometric back extensor strength measurement using a portable dynamometer has good reliability and validity.
Torsional Vibration in the National Wind Technology Center’s 2.5-Megawatt Dynamometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sethuraman, Latha; Keller, Jonathan; Wallen, Robb
2016-08-31
This report documents the torsional drivetrain dynamics of the NWTC's 2.5-megawatt dynamometer as identified experimentally and as calculated using lumped parameter models using known inertia and stiffness parameters. The report is presented in two parts beginning with the identification of the primary torsional modes followed by the investigation of approaches to damp the torsional vibrations. The key mechanical parameters for the lumped parameter models and justification for the element grouping used in the derivation of the torsional modes are presented. The sensitivities of the torsional modes to different test article properties are discussed. The oscillations observed from the low-speed andmore » generator torque measurements were used to identify the extent of damping inherently achieved through active and passive compensation techniques. A simplified Simulink model of the dynamometer test article integrating the electro-mechanical power conversion and control features was established to emulate the torque behavior that was observed during testing. The torque response in the high-speed, low-speed, and generator shafts were tested and validated against experimental measurements involving step changes in load with the dynamometer operating under speed-regulation mode. The Simulink model serves as a ready reference to identify the torque sensitivities to various system parameters and to explore opportunities to improve torsional damping under different conditions.« less
40 CFR 86.215-94 - EPA urban dynamometer driving schedule.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.215-94 EPA urban dynamometer...
Comparison between overground and dynamometer manual wheelchair propulsion.
Koontz, Alicia M; Worobey, Lynn A; Rice, Ian M; Collinger, Jennifer L; Boninger, Michael L
2012-08-01
Laboratory-based simulators afford many advantages for studying physiology and biomechanics; however, they may not perfectly mimic wheelchair propulsion over natural surfaces. The goal of this study was to compare kinetic and temporal parameters between propulsion overground on a tile surface and on a dynamometer. Twenty-four experienced manual wheelchair users propelled at a self-selected speed on smooth, level tile and a dynamometer while kinetic data were collected using an instrumented wheel. A Pearson correlation test was used to examine the relationship between propulsion variables obtained on the dynamometer and the overground condition. Ensemble resultant force and moment curves were compared using cross-correlation and qualitative analysis of curve shape. User biomechanics were correlated (R ranging from 0.41 to 0.83) between surfaces. Overall, findings suggest that although the dynamometer does not perfectly emulate overground propulsion, wheelchair users were consistent with the direction and amount of force applied, the time peak force was reached, push angle, and their stroke frequency between conditions.
Comparison Between Overground and Dynamometer Manual Wheelchair Propulsion
Worobey, Lynn A.; Rice, Ian M.; Collinger, Jennifer L.; Boninger, Michael L.
2017-01-01
Laboratory-based simulators afford many advantages for studying physiology and biomechanics; however, they may not perfectly mimic wheelchair propulsion over natural surfaces. The goal of this study was to compare kinetic and temporal parameters between propulsion overground on a tile surface and on a dynamometer. Twenty-four experienced manual wheelchair users propelled at a self-selected speed on smooth, level tile and a dynamometer while kinetic data were collected using an instrumented wheel. A Pearson correlation test was used to examine the relationship between propulsion variables obtained on the dynamometer and the overground condition. Ensemble resultant force and moment curves were compared using cross-correlation and qualitative analysis of curve shape. User biomechanics were correlated (R ranging from 0.41 to 0.83) between surfaces. Overall, findings suggest that although the dynamometer does not perfectly emulate overground propulsion, wheelchair users were consistent with the direction and amount of force applied, the time peak force was reached, push angle, and their stroke frequency between conditions. PMID:22085811
Dulac, Maude; Boutros, Guy El Hajj; Pion, Charlotte; Barbat-Artigas, Sébastien; Gouspillou, Gilles; Aubertin-Leheudre, Mylène
2016-01-01
To investigate whether handgrip strength normalized to body weight could be a useful clinical tool to identify dynapenia and assess functional capacity in post-menopausal women. A total of 136 postmenopausal women were recruited. Body composition (Dual Energy X-ray Absorptiometry [DEXA], Bio-electrical Impedence Analysis [BIA]), grip strength (dynamometer) and functional capacity (senior fitness tests) were evaluated. Dynapenia was established according to a handgrip strength index (handgrip strength divided by body weight (BW) in Kg/KgBW) obtained from a reference population of young women: Type I dynapenic (<0.44 kg/KgBW) and type II dynapenic (<0.35 kg/KgBW). The results show a positive correlation between handgrip strength index (in kg/KgBW) and alternate-step test (r=0.30, p<0.001), chair-stand test (r=0.25, p<0.005) and one-leg stance test (r=0.335, p<0.001). The results also showed a significant difference in non-dynapenic compared to type I dynapenic and type II dynapenic for the chair-stand test (Non-dynapenic: 12.0±3.0; Type I: 11.7±2.5; Type II: 10.3±3.0) (p=0.037 and p=0.005, respectively) and the one-leg stance test (Non-dynapenic: 54.2±14.2; Type I: 43.8±21.4; Type II: 35.0±21.8) (p=0.030 and p=0.004, respectively). Finally, a significant difference was observed between type II dynapenic and non-dynapenic for the chair-stand test (p=0.032), but not with type I dynapenic. The results showed that handgrip strength was positively correlated with functional capacity. In addition, non-dynapenic women displayed a better functional status when compared to type I and type II dynapenic women. Thus, the determination of the handgrip strength thresholds could be an accessible and affordable clinical tool to identify people at risk of autonomy loss.
Liu, Mingyao; Bing, Junjun; Xiao, Li; Yun, Kang; Wan, Liang
2018-01-01
Cutting force measurement is of great importance in machining processes. Hence, various methods of measuring the cutting force have been proposed by many researchers. In this work, a novel integrated rotating dynamometer based on fiber Bragg grating (FBG) was designed, constructed, and tested to measure four-component cutting force. The dynamometer consists of FBGs that are pasted on the newly designed elastic structure which is then mounted on the rotating spindle. The elastic structure is designed as two mutual-perpendicular semi-octagonal rings. The signals of the FBGs are transmitted to FBG interrogator via fiber optic rotary joints and optical fiber, and the wavelength values are displayed on a computer. In order to determine the static and dynamic characteristics, many tests have been done. The results show that it is suitable for measuring cutting force. PMID:29670062
Liu, Mingyao; Bing, Junjun; Xiao, Li; Yun, Kang; Wan, Liang
2018-04-18
Cutting force measurement is of great importance in machining processes. Hence, various methods of measuring the cutting force have been proposed by many researchers. In this work, a novel integrated rotating dynamometer based on fiber Bragg grating (FBG) was designed, constructed, and tested to measure four-component cutting force. The dynamometer consists of FBGs that are pasted on the newly designed elastic structure which is then mounted on the rotating spindle. The elastic structure is designed as two mutual-perpendicular semi-octagonal rings. The signals of the FBGs are transmitted to FBG interrogator via fiber optic rotary joints and optical fiber, and the wavelength values are displayed on a computer. In order to determine the static and dynamic characteristics, many tests have been done. The results show that it is suitable for measuring cutting force.
Wind Turbine Gearbox Condition Monitoring Round Robin Study - Vibration Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheng, S.
2012-07-01
The Gearbox Reliability Collaborative (GRC) at the National Wind Technology Center (NWTC) tested two identical gearboxes. One was tested on the NWTCs 2.5 MW dynamometer and the other was field tested in a turbine in a nearby wind plant. In the field, the test gearbox experienced two oil loss events that resulted in damage to its internal bearings and gears. Since the damage was not severe, the test gearbox was removed from the field and retested in the NWTCs dynamometer before it was disassembled. During the dynamometer retest, some vibration data along with testing condition information were collected. These datamore » enabled NREL to launch a Wind Turbine Gearbox Condition Monitoring Round Robin project, as described in this report. The main objective of this project was to evaluate different vibration analysis algorithms used in wind turbine condition monitoring (CM) and find out whether the typical practices are effective. With involvement of both academic researchers and industrial partners, the project sets an example on providing cutting edge research results back to industry.« less
2017-01-01
Objective To investigate the reliability and validity of a new method for isometric back extensor strength measurement using a portable dynamometer. Methods A chair equipped with a small portable dynamometer was designed (Power Track II Commander Muscle Tester). A total of 15 men (mean age, 34.8±7.5 years) and 15 women (mean age, 33.1±5.5 years) with no current back problems or previous history of back surgery were recruited. Subjects were asked to push the back of the chair while seated, and their isometric back extensor strength was measured by the portable dynamometer. Test-retest reliability was assessed with intraclass correlation coefficient (ICC). For the validity assessment, isometric back extensor strength of all subjects was measured by a widely used physical performance evaluation instrument, BTE PrimusRS system. The limit of agreement (LoA) from the Bland-Altman plot was evaluated between two methods. Results The test-retest reliability was excellent (ICC=0.82; 95% confidence interval, 0.65–0.91). The Bland-Altman plots demonstrated acceptable agreement between the two methods: the lower 95% LoA was −63.1 N and the upper 95% LoA was 61.1 N. Conclusion This study shows that isometric back extensor strength measurement using a portable dynamometer has good reliability and validity. PMID:29201818
Simulation of diesel engine emissions on the example of Fiat Panda in the NEDC test
NASA Astrophysics Data System (ADS)
Botwinska, Katarzyna; Mruk, Remigiusz; Słoma, Jacek; Tucki, Karol; Zaleski, Mateusz
2017-10-01
Road transport may be deemed a strategic branch of modern economy. Unfortunately, a rapid increase in the number of on-road motor vehicles entails some negative consequences as well, for instance, excessive concentration of exhausts produced by engines which results in deterioration of air quality. EURO emission standards which define acceptable limits for exhaust emissions of power units is an example of an activity performed in attempt to improve air quality. The EURO standard defines permissible amount of exhausts produced by a vehicle. Presently new units are examined through NEDC test. For the purpose of this thesis, a virtual test stand in a form of a computer simulation of a chassis dynamometer was used to simulate emission of a diesel engine (compression-ignition engine) in the NEDC test. Actual parameters of the 1.3 MultiJet engine of the Fiat Panda passenger car of 2014 were applied in the model. The simulation was carried out in the Matlab Simulink environment. The simulation model of the Fiat Panda passenger car enables the designation of the emission waveform for all test stages which corresponds to the values received during an approval test in real-life conditions.
Sipers, Walther M W H; Verdijk, Lex B; Sipers, Simone J E; Schols, Jos M G A; van Loon, Luc J C
2016-05-01
Geriatric patients with low skeletal muscle mass and strength generally have a relatively poor clinical outcome following acute illness. Therefore, it is recommended to routinely assess skeletal muscle mass and strength in patients admitted to the acute care geriatric ward. Handgrip strength is generally measured as a proxy for muscle strength and/or functional performance. To compare the applicability and test-retest reliability of measuring handgrip strength using the Jamar dynamometer and the Martin Vigorimeter in geriatric patients during hospitalization. A total of 96 geriatric patients (age 85 ± 5 y) admitted to the acute care geriatric ward participated in this study. Handgrip strength was assessed 3 times on 2 different occasions within 1 week of hospital admission using both the Jamar dynamometer and the Martin Vigorimeter. Maximal handgrip strength as determined over the 3 successive attempts performed on 2 occasions averaged 17 ± 7 kg and 35 ± 13 kPa when using the Jamar dynamometer and Martin Vigorimeter, respectively. Handgrip strength was significantly greater when using the dominant versus nondominant hand using both the Jamar dynamometer (17 ± 7 kg vs 16 ± 7 kg; P = .003) and Martin Vigorimeter (34 ± 12 kPa vs 33 ± 13 kPa; P = .022). Test-retest reliability showed an ICC of 0.94 and 0.92 when applying the Jamar dynamometer or Martin Vigorimeter, respectively (both P < .001). Furthermore, handgrip strength assessed with the Jamar and Martin Vigorimeter showed a strong correlation for both the first (ρ = 0.83, P < .001) and second measurement (ρ = 0.79, P < .001). Almost 80% of the geriatric patients needed help from nursing staff with transfer from bed to an arm-rested chair measuring handgrip strength with the Jamar dynamometer according to the Southampton protocol, which is not necessary when using the Martin Vigorimeter. The Martin Vigorimeter represents a reliable and more practical tool than the Jamar dynamometer to assess handgrip strength in the geriatric patient on admission to the acute geriatric ward. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.
Exploratory development of a glass ceramic automobile thermal reactor. [anti-pollution devices
NASA Technical Reports Server (NTRS)
Gould, R. E.; Petticrew, R. W.
1973-01-01
This report summarizes the design, fabrication and test results obtained for glass-ceramic (CER-VIT) automotive thermal reactors. Several reactor designs were evaluated using both engine-dynamometer and vehicle road tests. A maximum reactor life of about 330 hours was achieved in engine-dynamometer tests with peak gas temperatures of about 1065 C (1950 F). Reactor failures were mechanically induced. No evidence of chemical degradation was observed. It was concluded that to be useful for longer times, the CER-VIT parts would require a mounting system that was an improvement over those tested in this program. A reactor employing such a system was designed and fabricated.
Design and evaluation of experimental ceramic automobile thermal reactors
NASA Technical Reports Server (NTRS)
Stone, P. L.; Blankenship, C. P.
1974-01-01
The paper summarizes the results obtained in an exploratory evaluation of ceramics for automobile thermal reactors. Candidate ceramic materials were evaluated in several reactor designs using both engine dynamometer and vehicle road tests. Silicon carbide contained in a corrugated metal support structure exhibited the best performance, lasting 1100 hours in engine dynamometer tests and for more than 38,600 kilimeters (24,000 miles) in vehicle road tests. Although reactors containing glass-ceramic components did not perform as well as silicon carbide, the glass-ceramics still offer good potential for reactor use with improved reactor designs.
Design and evaluation of experimental ceramic automobile thermal reactors
NASA Technical Reports Server (NTRS)
Stone, P. L.; Blankenship, C. P.
1974-01-01
The results obtained in an exploratory evaluation of ceramics for automobile thermal reactors are summarized. Candidate ceramic materials were evaluated in several reactor designs by using both engine-dynamometer and vehicle road tests. Silicon carbide contained in a corrugated-metal support structure exhibited the best performance, lasting 1100 hr in engine-dynamometer tests and more than 38,600 km (24000 miles) in vehicle road tests. Although reactors containing glass-ceramic components did not perform as well as those containing silicon carbide, the glass-ceramics still offer good potential for reactor use with improved reactor designs.
Baseline automotive gas turbine engine development program
NASA Technical Reports Server (NTRS)
Wagner, C. E. (Editor); Pampreen, R. C. (Editor)
1979-01-01
Tests results on a baseline engine are presented to document the automotive gas turbine state-of-the-art at the start of the program. The performance characteristics of the engine and of a vehicle powered by this engine are defined. Component improvement concepts in the baseline engine were evaluated on engine dynamometer tests in the complete vehicle on a chassis dynamometer and on road tests. The concepts included advanced combustors, ceramic regenerators, an integrated control system, low cost turbine material, a continuously variable transmission, power-turbine-driven accessories, power augmentation, and linerless insulation in the engine housing.
Habets, Bas; Staal, J Bart; Tijssen, Marsha; van Cingel, Robert
2018-01-10
To determine the intrarater reliability of the Humac NORM isokinetic dynamometer for concentric and eccentric strength tests of knee and shoulder muscles. 54 participants (50% female, average age 20.9 ± 3.1 years) performed concentric and eccentric strength measures of the knee extensors and flexors, and the shoulder internal and external rotators on two different Humac NORM isokinetic dynamometers, which were situated at two different centers. The knee extensors and flexors were tested concentrically at 60° and 180°/s, and eccentrically at 60° s. Concentric strength of the shoulder internal and external rotators, and eccentric strength of the external rotators were measured at 60° and 120°/s. We calculated intraclass correlation coefficients (ICCs), standard error of measurement, standard error of measurement expressed as a %, and the smallest detectable change to determine reliability and measurement error. ICCs for the knee tests ranged from 0.74 to 0.89, whereas ICC values for the shoulder tests ranged from 0.72 to 0.94. Measurement error was highest for the concentric test of the knee extensors and lowest for the concentric test of shoulder external rotators.
Adhesion testing of aircraft tires
NASA Technical Reports Server (NTRS)
Bobo, S. N.
1983-01-01
Adhesion testing appeared to offer a less burdensome alternative to replace some of the dynamometer tests. Accordingly, test results and data were requested from retreaders who had used adhesion testing.
Exploratory evaluation of ceramics for automobile thermal reactors
NASA Technical Reports Server (NTRS)
Stone, P. L.; Blankenship, C. P.
1972-01-01
An exploratory evaluation of ceramics for automobile thermal reactors was conducted. Potential ceramic materials were evaluated in several reactor designs using both engine dynamometer and vehicle road tests. Silicon carbide contained in a corrugated metal support structure exhibited the best performance lasting over 800 hours in engine dynamometer tests and over 15,000 miles (24,200 km) of vehicle road tests. Reactors containing glass-ceramic components did not perform as well as silicon carbide. But the glass-ceramics still offer good potential for reactor use. The results of this study are considered to be a reasonable demonstration of the potential use of ceramics in thermal reactors.
Buckner, Samuel L; Jenkins, Nathaniel D M; Costa, Pablo B; Ryan, Eric D; Herda, Trent J; Cramer, Joel T
2015-05-01
The purpose of the present study was to compare the passive angle-torque curves and the passive stiffness (PS, N m °(-)(1)) values recorded simultaneously from a load cell versus an isokinetic dynamometer during dorsiflexion stretch tolerance assessments in vivo. Nine healthy men (mean ± SD age = 21.4 ± 1.6 years) completed stretch tolerance assessments on a custom-built apparatus where passive torque was measured simultaneously from an isokinetic dynamometer and a load cell. Passive torque values that corresponded with the last 10° of dorsiflexion, verified by surface electromyographic amplitude, were analyzed for each device (θ1, θ2, θ3, …, θ10). Passive torque values measured with the load cell were greater (p ≤ 0.05) than the dynamometer torque values for θ4 through θ10. There were more statistical differentiations among joint angles for passive torque measured by the load cell, and the load cell measured a greater (p ≤ 0.01) increase in passive torque and PS than the isokinetic dynamometer. These findings suggested that when examining the angle-torque curves from passive dorsiflexion stretch tolerance tests, a load cell placed under the distal end of the foot may be more sensitive than the torque recorded from an isokinetic dynamometer. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Dulac, Maude; Boutros, Guy El Hajj; Pion, Charlotte; Barbat-Artigas, Sébastien; Gouspillou, Gilles; Aubertin-Leheudre, Mylène
2016-01-01
ABSTRACT Objective To investigate whether handgrip strength normalized to body weight could be a useful clinical tool to identify dynapenia and assess functional capacity in post-menopausal women. Method A total of 136 postmenopausal women were recruited. Body composition (Dual Energy X-ray Absorptiometry [DEXA], Bio-electrical Impedence Analysis [BIA]), grip strength (dynamometer) and functional capacity (senior fitness tests) were evaluated. Dynapenia was established according to a handgrip strength index (handgrip strength divided by body weight (BW) in Kg/KgBW) obtained from a reference population of young women: Type I dynapenic (<0.44 kg/KgBW) and type II dynapenic (<0.35 kg/KgBW). Results The results show a positive correlation between handgrip strength index (in kg/KgBW) and alternate-step test (r=0.30, p<0.001), chair-stand test (r=0.25, p<0.005) and one-leg stance test (r=0.335, p<0.001). The results also showed a significant difference in non-dynapenic compared to type I dynapenic and type II dynapenic for the chair-stand test (Non-dynapenic: 12.0±3.0; Type I: 11.7±2.5; Type II: 10.3±3.0) (p=0.037 and p=0.005, respectively) and the one-leg stance test (Non-dynapenic: 54.2±14.2; Type I: 43.8±21.4; Type II: 35.0±21.8) (p=0.030 and p=0.004, respectively). Finally, a significant difference was observed between type II dynapenic and non-dynapenic for the chair-stand test (p=0.032), but not with type I dynapenic. Conclusion The results showed that handgrip strength was positively correlated with functional capacity. In addition, non-dynapenic women displayed a better functional status when compared to type I and type II dynapenic women. Thus, the determination of the handgrip strength thresholds could be an accessible and affordable clinical tool to identify people at risk of autonomy loss. PMID:27683834
Prediction of in-use emissions of heavy-duty diesel vehicles from engine testing.
Yanowitz, Janet; Graboski, Michael S; McCormick, Robert L
2002-01-15
A model of a heavy-duty vehicle driveline with automatic transmission has been developed for estimating engine speed and load from vehicle speed. The model has been validated using emissions tests conducted on three diesel vehicles on a chassis dynamometer and then on the engines removed from the vehicles tested on an engine dynamometer. Nitrogen oxide (NOx) emissions were proportional to work done by the engine. For two of the engines, the NOx/horsepower(HP) ratio was the same on the engine and on the chassis dynamometer tests. For the third engine NOx/HP was significantly higher from the chassis test, possibly due to the use of dual engine maps. The engine certification test generated consistently less particulate matter emissions on a gram per brake horsepower-hour basis than the Heavy Duty Transient and Central Business District chassis cycles. A good linear correlation (r2 = 0.97 and 0.91) was found between rates of HP increase integrated over the test cycle and PM emissions for both the chassis and the engine tests for two of the vehicles. The model also shows how small changes in vehicle speeds can lead to a doubling of load on the engine. Additionally, the model showed that it is impossible to drive a vehicle cycle equivalent to the heavy-duty engine federal test procedure on these vehicles.
Simulation of Fatigue Crack Initiation at Corrosion Pits With EDM Notches
NASA Technical Reports Server (NTRS)
Smith, Stephen W.; Newman, John A.; Piascik, Robert S.
2003-01-01
Uniaxial fatigue tests were conducted to compare the fatigue life of laboratory produced corrosion pits, similar to those observed in the shuttle main landing gear wheel bolt-hole, and an electro-discharged-machined (EDM) flaw. EDM Jaws are used to simulate corrosion pits during shuttle wheel (dynamometer) testing. The aluminum alloy, (AA 7050) laboratory fatigue tests were conducted to simulate the local stress level contained in the wheel bolt-hole. Under this high local stress condition, the EDM notch produced a fatigue life similar to test specimens containing corrosion pits of similar size. Based on the laboratory fatigue test results, the EDM Jaw (semi-circular disc shaped) produces a local stress state similar to corrosion pits and can be used to simulate a corrosion pit during the shuttle wheel dynamometer tests.
Validity of linear encoder measurement of sit-to-stand performance power in older people.
Lindemann, U; Farahmand, P; Klenk, J; Blatzonis, K; Becker, C
2015-09-01
To investigate construct validity of linear encoder measurement of sit-to-stand performance power in older people by showing associations with relevant functional performance and physiological parameters. Cross-sectional study. Movement laboratory of a geriatric rehabilitation clinic. Eighty-eight community-dwelling, cognitively unimpaired older women (mean age 78 years). Sit-to-stand performance power and leg power were assessed using a linear encoder and the Nottingham Power Rig, respectively. Gait speed was measured on an instrumented walkway. Maximum quadriceps and hand grip strength were assessed using dynamometers. Mid-thigh muscle cross-sectional area of both legs was measured using magnetic resonance imaging. Associations of sit-to-stand performance power with power assessed by the Nottingham Power Rig, maximum gait speed and muscle cross-sectional area were r=0.646, r=0.536 and r=0.514, respectively. A linear regression model explained 50% of the variance in sit-to-stand performance power including muscle cross-sectional area (p=0.001), maximum gait speed (p=0.002), and power assessed by the Nottingham Power Rig (p=0.006). Construct validity of linear encoder measurement of sit-to-stand power was shown at functional level and morphological level for older women. This measure could be used in routine clinical practice as well as in large-scale studies. DRKS00003622. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Baldauf, Rich W; Gabele, Pete; Crews, William; Snow, Richard; Cook, J Rich
2005-09-01
The U.S. Environmental Protection Agency (EPA) implemented a program to identify tailpipe emissions of criteria and air-toxic contaminants from in-use, light-duty low-emission vehicles (LEVs). EPA recruited 25 LEVs in 2002 and measured emissions on a chassis dynamometer using the cold-start urban dynamometer driving schedule of the Federal Test Procedure. The emissions measured included regulated pollutants, particulate matter, speciated hydrocarbon compounds, and carbonyl compounds. The results provided a comparison of emissions from real-world LEVs with emission standards for criteria and air-toxic compounds. Emission measurements indicated that a portion of the in-use fleet tested exceeded standards for the criteria gases. Real-time regulated and speciated hydrocarbon measurements demonstrated that the majority of emissions occurred during the initial phases of the cold-start portion of the urban dynamometer driving schedule. Overall, the study provided updated emission factor data for real-world, in-use operation of LEVs for improved emissions modeling and mobile source inventory development.
The convertible engine: A dual-mode propulsion system
NASA Technical Reports Server (NTRS)
Mcardle, Jack G.
1988-01-01
A variable inlet guide vane (VIGV) convertible engine that could be used to power future high-speed rotorcraft was tested on an outdoor stand. The engine ran stably and smoothly in the turbofan, turboshaft, and dual (combined fan and shaft) power modes. In the turbofan mode with the VIGV open, fuel consumption was comparable to that of a conventional turbofan engine. In the turboshaft mode with the VIGV closed, fuel consumption was higher than that of present turboshaft engines because power was wasted in churning fan-tip air flow. In dynamic performance tests with a specially built digital engine control and using a waterbrake dynamometer for shaft load, the engine responded effectively to large steps in thrust command and shaft torque. Previous mission analyses of a conceptual X-wing rotorcraft capable of 400-knot cruise speed were revised to account for more fan-tip churning power loss that was originally estimated. The calculations confirm that using convertible engines rather than separate life and cruise engines would result in a smaller, lighter craft with lower fuel use and direct operating cost.
Associations between muscle structure and contractile performance in seniors.
Randhawa, Avleen; Wakeling, James M
2013-07-01
Changes in muscle structure due to aging occur in a process known as sarcopenia. These changes can alter muscle mechanics during contraction that may limit mobility in seniors. The purpose of this study was to investigate the effect of sarcopenia on muscle fascicle length, pennation and belly thickness in a contracting muscle during isokinetic movements. Fascicles within a pennate muscle shorten at a slower velocity than that of the muscle belly, in a process called belly gearing. Belly gearing may be affected by atrophy and so was also tested in these seniors. The gastrocnemii were tested using ultrasound from 10 young adults (20-40 years) and 9 seniors (70-85 years). The muscle structure was imaged during standing and maximal plantarflexion at four constant velocities on a dynamometer and torque, position and time were recorded during contractions. The muscle belly thickness and pennation in seniors were significantly lower than young adults during standing. Belly thickness, changes in pennation, the belly gearing, ankle torque and power output were all significantly lower in seniors during plantarflexion contractions of the medial gastrocnemius (MG) and lateral gastrocnemius (LG). The higher pennation observed in young adults is commonly associated with increased fascicle rotations during contraction causing an increased belly gearing. The decreased fascicle rotations in seniors resulted in reduced belly gearing but the size of this effect did not match the loss in strength or power from the muscles. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Rebuffet, P
1930-01-01
This investigation shows the attempt to improve the electrodynamomoter designed by Mr. Villey. The force to be measured acts on a flexible steel plate which is placed in front of a fixed plate. The deformation varies the original thickness of the layer of air between the two plates, thus causing a more rapid variation in the coefficient of electrostatic attraction of the two plates than in the capacity of the condenser formed by the dynamometer. The measurements are made by a differential method. The capacity of the test dynamometer is compared with that of a similar instrument of constant capacity, this comparison being made by means of an electrometer. Diagrams are shown of the dynamometer, the electrometer, and the electrical connections.
A rolling-sliding bench test for investigating rear axle lubrication
Stump, Benjamin C.; Zhou, Yan; Viola, Michael B.; ...
2018-02-07
An automotive rear axle is composed of a set of hypoid gears, whose contact surfaces experience a complex combination of rolling contact fatigue damage and sliding wear. Full-scale rear axle dynamometer tests are used in the industry for efficiency and durability assessment. Here, this study developed a bench-scale rolling-sliding test protocol by simulating the contact pressure, oil temperature, and lubrication regime experienced in a dynamometer duty cycle test. Initial bench results have demonstrated the ability of generating both rolling contact-induced micropitting and sliding wear and the feasibility of investigating the impact of slide-to-roll ratio, surface roughness, test duration, and oilmore » temperature on the friction behavior, vibration noise, and surface damage. Finally, this bench test will allow studying candidate rear axle lubricants and materials under relevant conditions.« less
A rolling-sliding bench test for investigating rear axle lubrication
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stump, Benjamin C.; Zhou, Yan; Viola, Michael B.
An automotive rear axle is composed of a set of hypoid gears, whose contact surfaces experience a complex combination of rolling contact fatigue damage and sliding wear. Full-scale rear axle dynamometer tests are used in the industry for efficiency and durability assessment. Here, this study developed a bench-scale rolling-sliding test protocol by simulating the contact pressure, oil temperature, and lubrication regime experienced in a dynamometer duty cycle test. Initial bench results have demonstrated the ability of generating both rolling contact-induced micropitting and sliding wear and the feasibility of investigating the impact of slide-to-roll ratio, surface roughness, test duration, and oilmore » temperature on the friction behavior, vibration noise, and surface damage. Finally, this bench test will allow studying candidate rear axle lubricants and materials under relevant conditions.« less
de Vasconcelos, Rodrigo Antunes; Bevilaqua-Grossi, Débora; Shimano, Antonio Carlos; Paccola, Cleber Jansen; Salvini, Tânia Fátima; Prado, Christiane Lanatovits; Junior, Wilson A. Mello
2015-01-01
Objectives: The aim of this study was to evaluate the reliability and validity of a modified isometric dynamometer (MID) in performance deficits of the knee extensor and flexor muscles in normal individuals and in those with ACL reconstructions. Methods: Sixty male subjects were invited to participate of the study, being divided into three groups with 20 subjects each: control group (GC), group of individuals with ACL reconstruction with patellar tendon graft (GTP, and group of individuals with ACL reconstruction with hamstrings graft (GTF). All individuals performed isometric tests in the MID, muscular strength deficits collected were subsequently compared to the tests performed on the Biodex System 3 operating in the isometric and isokinetic mode at speeds of 60°/s and 180o/s. Intraclass ICC correlation calculations were done in order to assess MID reliability, specificity, sensitivity and Kappa's consistency coefficient calculations, respectively, for assessing the MID's validity in detecting muscular deficits and intra- and intergroup comparisons when performing the four strength tests using the ANOVA method. Results: The modified isometric dynamometer (MID) showed excellent reliability and good validity in the assessment of the performance of the knee extensor and flexor muscles groups. In the comparison between groups, the GTP showed significantly greater deficits as compared to the GTF and GC groups. Conclusion: Isometric dynamometers connected to mechanotherapy equipments could be an alternative option to collect data concerning performance deficits of the extensor and flexor muscles groups of the knee in subjects with ACL reconstruction. PMID:27004175
Kusumoto, Yasuaki; Nitta, Osamu; Takaki, Kenji
2016-10-01
In the present study, we aimed to determine whether similarly loaded sit-to-stand exercises at different speeds improve the physiological cost of walking in children with spastic diplegia. This design was a single-blind randomized clinical trial. Sixteen children with cerebral palsy (CP), aged 12-18 years, with a diagnosis of spastic diplegia, were randomly allocated to a slow loaded sit-to-stand exercise group (n=8) and a self-paced loaded sit-to-stand exercise group (n=8). Loaded sit-to-stand exercise was conducted at home for 15min, 4 sets per day, 3-4days per week, for 6 weeks. The patients were evaluated immediately before the intervention and after the training. Lower limb muscle strength using a hand-held dynamometer, selective voluntary motor control using SCALE, 6-min walk distance (6MWD), and Physiological Cost Index (PCI) were measured. The 6MWD showed a significant difference before and after intervention. PCI showed a significant difference between the two groups and the two time points. 6MWD and the PCI improved after intervention in the slow sit-to-stand exercise group. Compared to loaded sit-to-stand exercise at a regular speed, slow low-loaded sit-to-stand exercise improved the 6MWD and PCI in children with CP, suggesting that this decrease in speed during exercise improves the physiological cost of walking in these children. Copyright © 2016 Elsevier Ltd. All rights reserved.
Effects of knee and ankle muscle fatigue on postural control in the unipedal stance.
Bizid, Riadh; Margnes, Eric; François, Yrieix; Jully, Jean Louis; Gonzalez, Gerard; Dupui, Philippe; Paillard, Thierry
2009-06-01
The aim of this study was to compare the effects of acute muscle fatigue of the ankle and knee musculature on postural control by immediate measures after performing fatiguing tasks (POST condition). One group of subjects (n = 8) performed a fatiguing task by voluntary contractions of the triceps surae (group TRI) and the other (n = 9) performed a fatiguing task by voluntary contractions of the quadriceps femoris (group QUA). Each muscle group was exercised until the loss of maximal voluntary contraction torque reached 50% (isokinetic dynamometer). Posture was assessed by measuring the centre of foot pressure (COP) with a force platform during a test of unipedal quiet standing posture with eyes closed. Initially (in PRE condition), the mean COP velocity was not significantly different between group TRI and group QUA. In POST condition, the mean COP velocity increased more in group QUA than in group TRI. The postural control was more impaired by knee muscle fatigue than by ankle muscle fatigue.
40 CFR 91.404 - Test procedure overview.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to be conducted on an engine dynamometer or equivalent load and speed measurement device. The exhaust... analyzed through the analytical system. (b) The tests are designed to determine the brake-specific...
40 CFR 89.6 - Reference materials.
Code of Federal Regulations, 2011 CFR
2011-07-01
... November 89: Recommended Practice for Engine Testing with Low Temperature Charge Air Cooler Systems in a Dynamometer Test Cell 89.327-96 SAE Paper 770141: Optimization of a Flame Ionization Detector for...
NASA Astrophysics Data System (ADS)
English, Kirk L.; Hackney, Kyle J.; De Witt, John K.; Ploutz-Snyder, Robert J.; Goetchius, Elizabeth L.; Ploutz-Snyder, Lori L.
2013-11-01
IntroductionInternational Space Station (ISS) crewmembers perform muscle strength and endurance testing pre- and postflight to assess the physiologic adaptations associated with long-duration exposure to microgravity. However, a reliable and standardized method to document strength changes in-flight has not been established. To address this issue, a proprietary dynamometer, the Muscle Atrophy Research and Exercise System (MARES) has been developed and flown aboard the ISS. The aims of this ground-based investigation were to: (1) evaluate the test-retest reliability of MARES and (2) determine its agreement with a commercially available isokinetic dynamometer previously used for pre- and postflight medical testing. MethodsSix males (179.5±4.7 cm; 82.0±8.7 kg; 31.3±4.0 yr) and four females (163.2±7.3 cm; 63.2±1.9 kg; 32.3±6.8 yr) completed two testing sessions on a HUMAC NORM isokinetic dynamometer (NORM) and two sessions on MARES using a randomized, counterbalanced, cross-over design. Peak torque values at 60° and 180° s-1 were calculated from five maximal repetitions of knee extension (KE) and knee flexion (KF) for each session. Total work at 180° s-1 was determined from the area under the torque versus displacement curve during 20 maximal repetitions of KE and KF. ResultsIntraclass correlation coefficients were relatively high for both devices (0.90-0.99). Only one dependent measure, KE peak torque at 60° s-1 exhibited good concordance between devices (ρ=0.92) and a small average difference (0.9±17.3 N m). ConclusionMARES demonstrated acceptable test-retest reliability and thus should serve as a good tool to monitor in-flight strength changes. However, due to poor agreement with NORM, it is not advisable to compare absolute values obtained on these devices.
Design and Development of a Three-Component Force Sensor for Milling Process Monitoring
Li, Yingxue; Zhao, Yulong; Fei, Jiyou; Qin, Yafei; Zhao, You; Cai, Anjiang; Gao, Song
2017-01-01
A strain-type three-component table dynamometer is presented in this paper, which reduces output errors produced by cutting forces imposed on the different milling positions of a workpiece. A sensor structure with eight parallel elastic beams is proposed, and sensitive regions and Wheastone measuring circuits are also designed in consideration of eliminating the influences of the eccentric forces. To evaluate the sensor decoupling performance, both of the static calibration and dynamic milling test were implemented in different positions of the workpiece. Static experiment results indicate that the maximal deviation between the measured forces and the standard inputs is 4.58%. Milling tests demonstrate that with same machining parameters, the differences of the measured forces between different milling positions derived by the developed sensor are no larger than 6.29%. In addition, the natural frequencies of the dynamometer are kept higher than 2585.5 Hz. All the measuring results show that as a strain-type dynamometer, the developed force sensor has an improved eccentric decoupling accuracy with natural frequencies not much decreased, which owns application potential in milling process monitoring. PMID:28441354
Citaker, Seyit; Guclu-Gunduz, Arzu; Yazici, Gokhan; Bayraktar, Deniz; Nazliel, Bijen; Irkec, Ceyla
2013-01-01
Muscle strength and standing balance decrease in patients with Multiple Sclerosis (MS). The aim of the present study was to investigate the relationship between the lower extremity isometric muscle strength and standing balance in patients with MS. Forty-seven patients with MS and 10 healthy volunteers were included. Neurological disability level was assessed using Expanded Disability Status Scale (EDSS). Isometric strength of seven lower extremity muscles (hip flexor-extensor-abductor-adductor, knee flexor-extensor, and ankle dorsal flexor) was assessed using hand-held dynamometer. Duration of static one-leg standing balance was measured using digital chronometer. Hip flexor-extensor-abductor-adductor, knee flexor-extensor, and ankle dorsal flexor isometric muscle strength, and duration of one-leg standing balance were decreased in patients with MS when compared with controls (p < 0.05). All assessed lower extremity isometric muscle strength and EDSS level was related duration of one-leg standing balance in patients with MS. All assessed lower extremity isometric muscle strength (except ankle dorsal flexor) was related with EDSS. Hip flexor-extensor-abductor-adductor, knee flexor-extensor, and ankle dorsal flexor isometric muscle strength decreases in ambulatory MS patients. Lower extremity muscle weakness and neurological disability level are related with imbalance in MS population. Hip and knee region muscles weakness increases the neurological disability level. For the better balance and decrease neurological disability level whole lower extremity muscle strengthening should be included in rehabilitation programs.
Galiano-Castillo, Noelia; Cantarero-Villanueva, Irene; Fernández-Lao, Carolina; Ariza-García, Angélica; Díaz-Rodríguez, Lourdes; Del-Moral-Ávila, Rosario; Arroyo-Morales, Manuel
2016-10-15
The chronicity status of breast cancer survivors suggests a growing need for cancer rehabilitation. Currently, the use of technology is a promising strategy for providing support, as reflected in the emergence of research interest in Web-based interventions in cancer survivorship. A randomized controlled trial was conducted that included a total of 81 participants who had completed adjuvant therapy (except hormone treatment) for stage I to IIIA breast cancer. Participants were randomly assigned to an 8-week Internet-based, tailored exercise program (n = 40) or to a control group (n = 41).The instruments used at baseline, 8 weeks, and 6-month follow-up were the European Organization for Research and Treatment of Cancer Quality-of-Life Questionnaire Core 30 and its breast cancer module, the Brief Pain Inventory, the handgrip dynamometer, the isometric abdominal test, the back dynamometer, the multiple sit-to-stand test, and the Piper Fatigue Scale. After the intervention, the telerehabilitation group had significantly improved scores for global health status, physical, role, cognitive functioning, and arm symptoms (all P < .01) as well as pain severity (P = .001) and pain interference (P = .045) compared with the control group. Significant improvements also were observed favoring the telerehabilitation group for affected and nonaffected side handgrip (both P = .006), abdominal, back and lower body strength (all P < .01), and total fatigue (P < .001). These findings were maintained after 6 months of follow-up, except for role functioning, pain severity, and nonaffected side handgrip. Analysis was based on an intention-to-treat principle. This program may improve adverse effects and maintain benefits in breast cancer survivors. The results of this study have encouraging implications for cancer care. Cancer 2016;122:3166-74. © 2016 American Cancer Society. © 2016 American Cancer Society.
Malátová, Renata; Rokytová, Jitka; Stumbauer, Jan
2013-08-01
Dorsal pain caused by spine dysfunctions belongs to most frequent chronic illnesses. The muscles of the deep stabilising spine system work as a single functional unit where a dysfunction of only one muscle causes dysfunction of the whole system. Non-invasive, objective and statistically measurable evaluation of the condition of deep stabilising spine system has been made possible by the construction of muscular dynamometer. The aim of our work has been the assessment of deep stabilising spine system by diaphragm test and muscular dynamometer measurements. Based on an initial examination, a 6-week intervention programme was established including instructions on physiological body posture and correct basic body stabilisation for the given exercises and muscle strengthening. Consecutive measurements are then compared with the initial ones. It was presumed that a smaller number of the tested subjects would be able to correctly activate the deep stabilising spine system muscles before the intervention programme when compared to those after the intervention programme. A positive change of 87% has been found. It is clear that if a person actively approaches the programme, then positive adaptation changes on the deep stabilising spine system are seen only after 6 weeks. With the muscular dynamometer, activation of deep stabilising spine system can be objectively measured. Changes between the initial condition of a subject and the difference after some exercise or rehabilitation are especially noticeable. Also, the effect of given therapy or correct performance of the exercise can be followed and observed.
Proof Pressure Evaluation of Worn Passenger Car Tire Carcasses
DOT National Transportation Integrated Search
1976-11-01
Test work is described that examines the value of hydrostatic proof pressure testing in screening worn tire carcasses before retreading. Results are given from dynamometer wheel tests on a significant sample of retreaded passenger car tires. Each sam...
Comparisons between vehicular emissions from real-world in-use testing and EPA moves estimation.
DOT National Transportation Integrated Search
2012-07-01
"This research study developed a methodology to perform mandatory dynamometer vehicular emissions tests : on real roads, performed on-road emissions tests, and compared the test results to the estimates using the : current EPA emissions estimation mo...
Krasnow, Donna; Ambegaonkar, Jatin P; Stecyk, Shane; Wilmerding, M Virginia; Wyon, Matthew; Koutedakis, Yiannis
2011-12-01
Surface electromyography (sEMG) has been used in dance medicine research since the 1970s, but normalization procedures are not consistently employed in the field. The purpose of this project was to develop a portable anchored dynamometer (PAD) specifically for dance-related research. Due to the limited studies in the dance research literature using normalization procedures for sEMG data, a review of the procedures used in the exercise science literature was conducted. A portable anchored dynamometer was then developed and tested with dancers, using methods validated in previous literature. We collected sEMG maximum voluntary isometric contractions (MVIC, mV) from 10 female dancers (mean age 31.0 ± 15 yrs, mean height 163 ± 7.6 cm, mean weight 57.6 ± 6.9 kg, and 17.0 ± 13.9 yrs of training in ballet and/or modern dance) over three trials (5 sec each) for eight muscles bilaterally (quadriceps, tibialis anterior, abductor hallucis, gastrocnemius, hamstrings, gluteus maximus, erector spinae, and rectus abdominus). Consistency of data and feedback from dancers suggest that this dance-specific portable anchored dynamometer is effective for future sEMG studies in dance research.
40 CFR 89.307 - Dynamometer calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... master load-cell for each in-use range used. (5) The in-use torque measurement must be within 2 percent... torque measurement for each range used by the following method: (1) Warm up the dynamometer following the dynamometer manufacturer's specifications. (2) Determine the dynamometer calibration moment arm (a distance...
Initial development of a device for controlling manually applied forces.
Waddington, Gordon S; Adams, Roger D
2007-05-01
In both simulation and manual therapy studies, substantial variability has been shown when therapists attempt to replicate an applied force. Knowledge about the forces employed during treatment could reduce this variability. In the current project, a prototype for a mobilizing device incorporating a dynamometer was constructed. The prototype device was built around a conventional "hand-grip" dynamometer to give dial visibility during application of mobilizing forces and a moulded handle was used to increase the hand contact surface during force application. The variability of the mobilization forces produced was measured, and ratings of comfort during a simulated spinal mobilization technique were obtained from therapists. Thirty physiotherapists were randomly allocated to apply either: (i) their own estimate of a grade III mobilization force using their hands in a pisiform grip or (ii) a 100N force with the manual therapy dynamometer, and to rate comfort during the performance of both techniques on a 100mm visual analogue scale. Variance in dynamometer-dial-guided force application was always significantly less than the variance in therapist-concept-guided force application. Repeated-measures tests showed that the mean force produced at grade III was not significantly different from 100N, but physiotherapist comfort ratings were found to be significantly greater (P<0.01) when the manual therapy dynamometer was used. Manually applied force variability was significantly less and therapist comfort greater when using a device with visual access to a dial giving immediate force readout.
NASA Astrophysics Data System (ADS)
Wallace, Brian D.
A series of field tests and theoretical analyses were performed on various wind turbine rotor designs at two Penn State residential-scale wind-electric facilities. This work involved the prediction and experimental measurement of the electrical and aerodynamic performance of three wind turbines; a 3 kW rated Whisper 175, 2.4 kW rated Skystream 3.7, and the Penn State designed Carolus wind turbine. Both the Skystream and Whisper 175 wind turbines are OEM blades which were originally installed at the facilities. The Carolus rotor is a carbon-fiber composite 2-bladed machine, designed and assembled at Penn State, with the intent of replacing the Whisper 175 rotor at the off-grid system. Rotor aerodynamic performance is modeled using WT_Perf, a National Renewable Energy Laboratory developed Blade Element Momentum theory based performance prediction code. Steady-state power curves are predicted by coupling experimentally determined electrical characteristics with the aerodynamic performance of the rotor simulated with WT_Perf. A dynamometer test stand is used to establish the electromechanical efficiencies of the wind-electric system generator. Through the coupling of WT_Perf and dynamometer test results, an aero-electro-mechanical analysis procedure is developed and provides accurate predictions of wind system performance. The analysis of three different wind turbines gives a comprehensive assessment of the capability of the field test facilities and the accuracy of aero-electro-mechanical analysis procedures. Results from this study show that the Carolus and Whisper 175 rotors are running at higher tip-speed ratios than are optimum for power production. The aero-electro-mechanical analysis predicted the high operating tip-speed ratios of the rotors and was accurate at predicting output power for the systems. It is shown that the wind turbines operate at high tip-speeds because of a miss-match between the aerodynamic drive torque and the operating torque of the wind-system generator. Through the change of load impedance on the wind generator, the research facility has the ability to modify the rotational speed of the wind turbines, allowing the rotors to perform closer to their optimum tip-speed. Comparisons between field test data and performance predictions show that the aero-electro-mechanical analysis was able to predict differences in power production and rotational speed which result from changes in the system load impedance.
Evaluation of the micro-carburetor
NASA Technical Reports Server (NTRS)
Weiss, M. F.; Hall, R. A.; Mazor, S. D.
1981-01-01
A prototype sonic, variable-venturi automotive carburetor was evaluated for its effects on vehicle performance, fuel economy, and exhaust emissions. A 350 CID Chevrolet Impala vehicle was tested on a chassis dynamometer over the 1975 Federal Test Procedure, urban driving cycle. The Micro-carburetor was tested and compared with stock and modified-stock engine configurations. Subsequently, the test vehicle's performance characteristics were examined with the stock carburetor and again with the Micro-carburetor in a series of on-road driveability tests. The test engine was then removed from the vehicle and installed on an engine dynamometer. Engine tests were conducted to compare the fuel economy, thermal efficiency, and cylinder-to-cylinder mixture distribution of the Micro-carburetor to that of the stock configuration. Test results show increases in thermal efficiency and improvements in fuel economy at all test conditions. Improve fuel/air mixture preparation is implied from the information presented. Further improvements in fuel economy and exhaust emissions are possible through a detailed recalibration of the Micro-carburetor.
-7162 Don assists with the installation and maintenance of the NWTC's field test turbines as well as with test article installations and testing in the Structural Testing Laboratory and both dynamometer facilities. He participates in the operation and maintenance of the field test sites and meteorological
Dorner, Thomas Ernst; Berner, Carolin; Haider, Sandra; Grabovac, Igor; Lamprecht, Thomas; Fenzl, Karl Heinrich; Erlacher, Ludwig
2018-06-01
The aim of this study was to examine sexual health in patients with rheumatoid arthritis (RA), and to analyse factors associated with sexual health with a focus on physical fitness. One hundred RA patients aged between 18 and 65 years were included in a cross-sectional study. Handgrip strength and knee extensor strength were measured with a dynamometer, and physical performance with the Short Physical Performance Battery (SPPB). Fifty-four patients, mean age 47.8 (SD 10.6) years, 61% female, answered a questionnaire about sexual health. Fifty-seven percent reported, at least, sometimes having difficulty with sexual intercourse (27.8% due to joint stiffness, 24.1% due to fatigue, 18.5% due to pain). Handgrip strength and knee extensor strength significantly correlated with the desire to engage in sexual intercourse, frequency of sexual contact and satisfaction with overall sex life. The SPPB total score correlated with satisfaction with overall sex life, and the SPPB repeated chair stands test with the desire to have sexual intercourse and satisfaction with overall sex life. After adjusting for age, gender, disease activity, comorbidity, co-medication and pain intensity, the repeated chair stands test remained significantly associated with the frequency of sexual contact (0.53; 0.01-1.05) and with satisfaction with overall sex life (1.39; 0.28-2.51). The results of this study show that problems with sexual health are highly prevalent in patients with RA. The ability to rise from a chair is associated with sexual function, independent of disease activity and pain intensity.
NASA Astrophysics Data System (ADS)
Crumley, R. L.; MacDowall, R. D.; Hardin, J. E.; Burke, A. F.
1989-04-01
This report is concerned with the test and evaluation of the ETX-I electric test vehicle, which is a Mercury LN7 retrofitted with the single-shaft ac electric powertrain developed by Ford and General Electric under contract to the U.S. Department of Energy (DOE) during the period 1982 to 1985. The lead-acid battery used in the ETX-I was developed by Lucas Chloride Electric Vehicle (EV) Systems (LCEVS) as part of the same DOE contract. Extensive tests of the powertrain and battery were done by General Electric and Lucas Chloride before they were integrated into the ETX-I test vehicle by Ford. Ford did limited testing of the ETX-I vehicle on a chassis dynamometer to determine the energy consumption of the powertrain for several driving schedules before the vehicle was shipped to INEL for complete dynamometer testing. Ford also performed track tests with the ETX-I to determine its acceleration performance characteristics.
40 CFR 89.311 - Analyzer calibration frequency.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test... rejection ratio and the CO2 rejection ratio as specified in § 89.318. (e) Verify that the dynamometer test...
Factor Analysis of Various Anaerobic Power Tests.
ERIC Educational Resources Information Center
Manning, James M.; And Others
A study investigated the relationship between selected anthropometric variables and of numerous anaerobic power tests with measures obtained on an isokinetic dynamometer. Thirty-one male college students performed several anaerobic power tests, including: the vertical jump using the Lewis formula; the Margaria-Kalamen stair climb test; the Wingate…
Testing and Benchmarking a 2014 GM Silverado 6L80 Six Speed Automatic Transmission
Describe the method and test results of EPA’s partial transmission benchmarking process which involves installing both the engine and transmission in an engine dynamometer test cell with the engine wire harness tethered to its vehicle parked outside the test cell.
Compilation of Steady State Automotive Engine Test Data
DOT National Transportation Integrated Search
1978-09-01
Experimental data were obtained in dynamometer tests of automotive engines used in the United States. The objective of this program is to obtain engine performance data for determining fuel consumption and emissions (carbon monoxide, hydrocarbons, an...
On-road heavy-duty diesel particulate matter emissions modeled using chassis dynamometer data.
Kear, Tom; Niemeier, D A
2006-12-15
This study presents a model, derived from chassis dynamometer test data, for factors (operational correction factors, or OCFs) that correct (g/mi) heavy-duty diesel particle emission rates measured on standard test cycles for real-world conditions. Using a random effects mixed regression model with data from 531 tests of 34 heavy-duty vehicles from the Coordinating Research Council's E55/E59 research project, we specify a model with covariates that characterize high power transient driving, time spent idling, and average speed. Gram per mile particle emissions rates were negatively correlated with high power transient driving, average speed, and time idling. The new model is capable of predicting relative changes in g/mi on-road heavy-duty diesel particle emission rates for real-world driving conditions that are not reflected in the driving cycles used to test heavy-duty vehicles.
Body composition explains sex differential in physical performance among older adults.
Tseng, Lisa A; Delmonico, Matthew J; Visser, Marjolein; Boudreau, Robert M; Goodpaster, Bret H; Schwartz, Ann V; Simonsick, Eleanor M; Satterfield, Suzanne; Harris, Tamara; Newman, Anne B
2014-01-01
Older women have higher percent body fat, poorer physical function, lower strength, and higher rates of nonfatal chronic conditions than men. We sought to determine whether these differences explained physical performance differences between men and women. Physical performance was assessed in the Health, Aging and Body Composition study in 2,863 men and women aged 70-79 with a composite 0-4 point score consisting of chair stands, standing balance including one-leg stand, and 6-m usual and narrow walk tests. Total body composition was measured by dual x-ray absorptiometry, thigh composition by computed tomography, and knee extensor strength by isokinetic dynamometer. Analysis of covariance estimated least square mean performance scores for men and women. Men had higher performance scores than women (least square means: 2.33±0.02 vs 2.03±0.02, p < .0001), adjusted for race, study site, age, and height. Body composition measures (total body fat and thigh muscle area, muscle density, subcutaneous fat, and intermuscular fat) accounted for differences between men and women (least square means: 2.15±0.02 vs 2.17±0.02, p = .53). Higher strength in men partly explained the sex difference (least square means: 2.28±0.02 vs 2.12±0.02, p < .0001). Strength attenuated the association of thigh muscle mass with performance. Chronic health conditions did not explain the sex difference. In a well-functioning cohort, poorer physical function in women compared with men can be explained predominantly by their higher fat mass, but also by other body composition differences. The higher proportion of body fat in women may put them at significant biomechanical disadvantage for greater disability in old age.
Development of a precision, six-axis laboratory dynamometer
NASA Technical Reports Server (NTRS)
Champagne, P. J.; Cordova, S. A.; Jacoby, M. S.; Lorell, K. R.
1992-01-01
This paper describes the design, fabrication, test, and operation of a unique six axis force/torque dynamometer The specimen table used to hold components under test is supported in a full six axis kinematic mount. Support struts fabricated from high strength steel with special integral two axis flexures link the specimen table to the load cell transducers. Realtime force/torque coordinate transform, root mean squared calculation, and data averaging, and color six axis display with controllable scaling are provided by a specially programmed desktop computer. The extensive structural analysis and design optimization required to obtain a stiff, well damped, lightweight structure is described in detail. Geometric optimization of the kinematic mount and fabrication details of the struts are also described.
Development of a Tri-Axial Cutting Force Sensor for the Milling Process
Li, Yingxue; Zhao, Yulong; Fei, Jiyou; Zhao, You; Li, Xiuyuan; Gao, Yunxiang
2016-01-01
This paper presents a three-component fixed dynamometer based on a strain gauge, which reduces output errors produced by the cutting force imposed on different milling positions of the workpiece. A reformative structure of tri-layer cross beams is proposed, sensitive areas were selected, and corresponding measuring circuits were arranged to decrease the inaccuracy brought about by positional variation. To simulate the situation with a milling cutter moving on the workpiece and validate the function of reducing the output errors when the milling position changes, both static calibration and dynamic milling tests were implemented on different parts of the workpiece. Static experiment results indicate that with standard loads imposed, the maximal deviation between the measured forces and the standard inputs is 4.87%. The results of the dynamic milling test illustrate that with identical machining parameters, the differences in output variation between the developed sensor and standard dynamometer are no larger than 6.61%. Both static and dynamic experimental results demonstrate that the developed dynamometer is suitable for measuring milling force imposed on different positions of the workpiece, which shows potential applicability in machining a monitoring system. PMID:27007374
Effects of potassium titanate fiber on the wear of automotive brake linings
NASA Technical Reports Server (NTRS)
Halberstadt, M. L.; Mansfield, J. A.; Rhee, S. K.
1977-01-01
Asbestos reinforcing fiber in an automotive friction material was replaced by an experimental ingredient having better thermal stability, and the effects on wear and friction were studied. A friction materials test machine (SAE J661a) was used to determine friction and wear, under constant energy output conditions, as a function of temperature between 121 and 343 C (250 and 650 F). When potassium titanate fiber replaced one half of the asbestos in a standard commercial lining, with a 40 percent upward adjustment of phenolic resin content, wear above 204 C (400 F) was improved by 40% and friction by 30%. Tests on a full-scale inertial dynamometer supported the findings of the sample dynamometer tests. It was demonstrated that the potassium titanate fiber contributes directly to the improvement in wear and friction.
40 CFR 610.43 - Chassis dynamometer procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., the following modifications will be employed: (i) No evaporative emission loss, as specified by 40 CFR... no earlier than 36 hours before the emission test. (iii) While the test fuel must meet the... specified in § 600.111. (c) Steady state tests. Constant speed, road load tests may be conducted to help...
40 CFR 610.43 - Chassis dynamometer procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., the following modifications will be employed: (i) No evaporative emission loss, as specified by 40 CFR... no earlier than 36 hours before the emission test. (iii) While the test fuel must meet the... specified in § 600.111. (c) Steady state tests. Constant speed, road load tests may be conducted to help...
40 CFR 610.43 - Chassis dynamometer procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., the following modifications will be employed: (i) No evaporative emission loss, as specified by 40 CFR... no earlier than 36 hours before the emission test. (iii) While the test fuel must meet the... specified in § 600.111. (c) Steady state tests. Constant speed, road load tests may be conducted to help...
40 CFR 610.43 - Chassis dynamometer procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., the following modifications will be employed: (i) No evaporative emission loss, as specified by 40 CFR... no earlier than 36 hours before the emission test. (iii) While the test fuel must meet the... specified in § 600.111. (c) Steady state tests. Constant speed, road load tests may be conducted to help...
40 CFR 610.43 - Chassis dynamometer procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., the following modifications will be employed: (i) No evaporative emission loss, as specified by 40 CFR... no earlier than 36 hours before the emission test. (iii) While the test fuel must meet the... specified in § 600.111. (c) Steady state tests. Constant speed, road load tests may be conducted to help...
40 CFR 91.410 - Engine test cycle.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine test cycle. 91.410 Section 91...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.410 Engine... in dynamometer operation tests of marine engines. (b) During each non-idle mode the specified speed...
40 CFR 86.237-08 - Dynamometer test run, gaseous emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... minutes of the end of the sample collection phase of the test. Obtain methanol and formaldehyde sample... collection phase of the test. Obtain methanol and formaldehyde sample analyses, if applicable, within 24... the sample collection phase of the test. Obtain methanol and formaldehyde sample analyses, if...
40 CFR 86.237-08 - Dynamometer test run, gaseous emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... minutes of the end of the sample collection phase of the test. Obtain methanol and formaldehyde sample... collection phase of the test. Obtain methanol and formaldehyde sample analyses, if applicable, within 24... the sample collection phase of the test. Obtain methanol and formaldehyde sample analyses, if...
40 CFR 1065.920 - PEMS Calibrations and verifications.
Code of Federal Regulations, 2010 CFR
2010-07-01
... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Field Testing and Portable Emission Measurement Systems § 1065... verification. The verification consists of operating an engine over a duty cycle in the laboratory and... by laboratory equipment as follows: (1) Mount an engine on a dynamometer for laboratory testing...
40 CFR 90.404 - Test procedure overview.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test... operating conditions to be conducted on an engine dynamometer or equivalent load and speed measurement... to determine the brake-specific emissions of non-methane hydrocarbons. The test consists of three...
Van Driessche, Stijn; Van Roie, Evelien; Vanwanseele, Benedicte; Delecluse, Christophe
2018-01-01
Isotonic testing and measures of rapid power production are emerging as functionally relevant test methods for detection of muscle aging. Our objective was to assess reliability of rapid velocity and power measures in older adults using the isotonic mode of an isokinetic dynamometer. Sixty-three participants (aged 65 to 82 years) underwent a test-retest protocol with one week time interval. Isotonic knee extension tests were performed at four different loads: 0%, 25%, 50% and 75% of maximal isometric strength. Peak velocity (pV) and power (pP) were determined as the highest values of the velocity and power curve. Rate of velocity (RVD) and power development (RPD) were calculated as the linear slopes of the velocity- and power-time curve. Relative and absolute measures of test-retest reliability were analyzed using intraclass correlation coefficients (ICC), standard error of measurement (SEM) and Bland-Altman analyses. Overall, reliability was high for pV, pP, RVD and RPD at 0%, 25% and 50% load (ICC: .85 - .98, SEM: 3% - 10%). A trend for increased reliability at lower loads seemed apparent. The tests at 75% load led to range of motion failure and should be avoided. In addition, results demonstrated that caution is advised when interpreting early phase results (first 50ms). To conclude, our results support the use of the isotonic mode of an isokinetic dynamometer for testing rapid power and velocity characteristics in older adults, which is of high clinical relevance given that these muscle characteristics are emerging as the primary outcomes for preventive and rehabilitative interventions in aging research.
Performance Characteristics of 1977 Ford 300 CID Engine
DOT National Transportation Integrated Search
1980-02-01
Experimental data were obtained in dynamometer tests of a 1977 Ford 300 CID engine to determine fuel consumption and emissions (hydrocarbons, carbon monoxide, and oxides of Nitrogen) at steady-state engine operating modes. The objective of the test w...
DOT National Transportation Integrated Search
1981-01-01
Tests were performed on a prototyple Vokswagen (VW) Turbocharged (TC) Rabbit diesel vehicle on a chassis dynamometer. The vheicle was tested for fuel economy and emissions on the urban Federal test Procedure (FTP), Highway Fuel Economy Test (HFET), C...
Automotive Stirling engine development program
NASA Technical Reports Server (NTRS)
Ernst, W.; Piller, S.; Richey, A.; Simetkosky, M.; Antonelli, M. (Editor)
1982-01-01
Activities performed on Mod I engine testing and test results, progress in manufacturing, assembling and testing of a Mod I engine in the United States, P40 Stirling engine dynamometer and multifuels testing, analog/digital controls system testing, Stirling reference engine manufacturing and reduced size studies, components and subsystems, and computer code development are summarized.
40 CFR 1066.805 - Road-load power, test weight, and inertia weight class determination.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (a) Simulate a vehicle's test weight on the dynamometer using the appropriate equivalent test weight shown in Table 1 of this section. Equivalent test weights are established according to each vehicle's... weight class corresponding to each equivalent test weight; the inertia weight class allows for grouping...
40 CFR 86.518-78 - Dynamometer calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... down the dynamometer for each inertia load combination used. Coastdown times for the interval from 70... of conducting a dynamometer coastdown at one or more inertia-horsepower settings and comparing the...
40 CFR 86.518-78 - Dynamometer calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... down the dynamometer for each inertia load combination used. Coastdown times for the interval from 70... of conducting a dynamometer coastdown at one or more inertia-horsepower settings and comparing the...
40 CFR 86.518-78 - Dynamometer calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... down the dynamometer for each inertia load combination used. Coastdown times for the interval from 70... of conducting a dynamometer coastdown at one or more inertia-horsepower settings and comparing the...
40 CFR 86.518-78 - Dynamometer calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... down the dynamometer for each inertia load combination used. Coastdown times for the interval from 70... of conducting a dynamometer coastdown at one or more inertia-horsepower settings and comparing the...
40 CFR 86.518-78 - Dynamometer calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... down the dynamometer for each inertia load combination used. Coastdown times for the interval from 70... of conducting a dynamometer coastdown at one or more inertia-horsepower settings and comparing the...
1978-12-01
and chemical data and dynamomet er and field perfo rmance. The initial stud y produced internal and group correlations among the data and suggests a...sm all (a corre lation of I .0 i~ ~~r kct cor rela t ion ’, Prin cip al comp onent .iii,il ~ 515 Was enmp lo~ ed to stud ~ lhe iner al l re hi t i...Additive ) K = Potassium (Addit ive) V N = Nitr ogen (Additive ) . V Mg = Magnesium (Additive ) B = Boron (Additive ) Other = To include wear and
40 CFR 86.118-00 - Dynamometer calibrations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 1977 and Later Model Year New Light-Duty Vehicles and New Light-Duty Trucks and New Otto-Cycle Complete... required. (b) For large single roll electric dynamometers or equivalent dynamometer configurations, the...
High energy density propulsion systems and small engine dynamometer
NASA Astrophysics Data System (ADS)
Hays, Thomas
2009-07-01
Scope and Method of Study. This study investigates all possible methods of powering small unmanned vehicles, provides reasoning for the propulsion system down select, and covers in detail the design and production of a dynamometer to confirm theoretical energy density calculations for small engines. Initial energy density calculations are based upon manufacturer data, pressure vessel theory, and ideal thermodynamic cycle efficiencies. Engine tests are conducted with a braking type dynamometer for constant load energy density tests, and show true energy densities in excess of 1400 WH/lb of fuel. Findings and Conclusions. Theory predicts lithium polymer, the present unmanned system energy storage device of choice, to have much lower energy densities than other conversion energy sources. Small engines designed for efficiency, instead of maximum power, would provide the most advantageous method for powering small unmanned vehicles because these engines have widely variable power output, loss of mass during flight, and generate rotational power directly. Theoretical predictions for the energy density of small engines has been verified through testing. Tested values up to 1400 WH/lb can be seen under proper operating conditions. The implementation of such a high energy density system will require a significant amount of follow-on design work to enable the engines to tolerate the higher temperatures of lean operation. Suggestions are proposed to enable a reliable, small-engine propulsion system in future work. Performance calculations show that a mature system is capable of month long flight times, and unrefueled circumnavigation of the globe.
Performance Characteristics of 1977 General Motors 350 CID Engine
DOT National Transportation Integrated Search
1980-02-01
Experimental data were obtained in dynamometer tests of a 1977 GM 350 CID engine to determine fuel consumption and emissions (hydrocarbons, carbon monoxide, and oxides of nitrogen) at steady-state engine operating modes. The objective of the test was...
Performance Characteristics of 1977 American Motors 304 CID Engine
DOT National Transportation Integrated Search
1980-02-01
Experimental data were obtained in dynamometer tests of a 1977 AM 304 CID engine to determine fuel consumption and emissions (hydrocarbons, carbon monoxide, and oxides of nitrogen) at steady-state engine operating modes. The objective of the test was...
Johansson, Fredrik R.; Skillgate, Eva; Lapauw, Mattis L.; Clijmans, Dorien; Deneulin, Valentijn P.; Palmans, Tanneke; Engineer, Human Kinetic; Cools, Ann M.
2015-01-01
Context Shoulder strength assessment plays an important role in the clinical examination of the shoulder region. Eccentric strength measurements are of special importance in guiding the clinician in injury prevention or return-to-play decisions after injury. Objective To examine the absolute and relative reliability and validity of a standardized eccentric strength-measurement protocol for the glenohumeral external rotators. Design Descriptive laboratory study. Setting Testing environment at the Department of Rehabilitation Sciences and Physiotherapy of Ghent University, Belgium. Patients or Other Participants Twenty-five healthy participants (9 men and 16 women) without any history of shoulder pain were tested by 2 independent assessors using a handheld dynamometer (HHD) and underwent an isokinetic testing procedure. Intervention(s) The clinical protocol used an HHD, a DynaPort accelerometer to measure acceleration and angular velocity of testing 30°/s over 90° of range of motion, and a Biodex dynamometer to measure isokinetic activity. Main Outcome Measure(s) Three eccentric strength measurements: (1) tester 1 with the HHD, (2) tester 2 with the HHD, and (3) Biodex isokinetic strength measurement. Results The intratester reliability was excellent (0.879 and 0.858), whereas the intertester reliability was good, with an intraclass correlation coefficient between testers of 0.714. Pearson product moment correlation coefficients of 0.78 and 0.70 were noted between the HHD and the isokinetic data, showing good validity of this new procedure. Conclusions Standardized eccentric rotator cuff strength can be tested and measured in the clinical setting with good-to-excellent reliability and validity using an HHD. PMID:25974381
40 CFR 86.336-79 - Diesel engine test cycle.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Diesel engine test cycle. 86.336-79... New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.336-79 Diesel engine test cycle. (a) The following 13-mode cycle shall be followed in dynamometer operation...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Heavy-Duty Engines; Smoke Exhaust Test Procedure § 86.884-12 Test run. (a) The temperature of the air... may be used, if desired, but no allowance will be made for possible increased smoke emissions because... required to perform the acceleration in the dynamometer cycle for smoke emission tests (§ 86.884-7(a)(2...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Heavy-Duty Engines; Smoke Exhaust Test Procedure § 86.884-12 Test run. (a) The temperature of the air... may be used, if desired, but no allowance will be made for possible increased smoke emissions because... required to perform the acceleration in the dynamometer cycle for smoke emission tests (§ 86.884-7(a)(2...
10 CFR 474.4 - Test procedures.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Test procedures. 474.4 Section 474.4 Energy DEPARTMENT OF...; PETROLEUM-EQUIVALENT FUEL ECONOMY CALCULATION § 474.4 Test procedures. (a) The electric vehicle energy... Schedule and Urban Dynamometer Driving Schedule test cycles at 40 CFR parts 86 and 600. (b) The “Special...
30 CFR 7.88 - Test to determine the gaseous ventilation rate.
Code of Federal Regulations, 2013 CFR
2013-07-01
... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Diesel Engines... engine to the dynamometer and attach the sampling and measurement devices specified in § 7.86. (2) A... zeroed and spanned at the analyzer range to be used prior to testing. (4) Run the engine. (i) The...
30 CFR 7.88 - Test to determine the gaseous ventilation rate.
Code of Federal Regulations, 2014 CFR
2014-07-01
... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Diesel Engines... engine to the dynamometer and attach the sampling and measurement devices specified in § 7.86. (2) A... zeroed and spanned at the analyzer range to be used prior to testing. (4) Run the engine. (i) The...
30 CFR 7.88 - Test to determine the gaseous ventilation rate.
Code of Federal Regulations, 2010 CFR
2010-07-01
... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Diesel Engines... engine to the dynamometer and attach the sampling and measurement devices specified in § 7.86. (2) A... zeroed and spanned at the analyzer range to be used prior to testing. (4) Run the engine. (i) The...
30 CFR 7.88 - Test to determine the gaseous ventilation rate.
Code of Federal Regulations, 2012 CFR
2012-07-01
... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Diesel Engines... engine to the dynamometer and attach the sampling and measurement devices specified in § 7.86. (2) A... zeroed and spanned at the analyzer range to be used prior to testing. (4) Run the engine. (i) The...
30 CFR 7.88 - Test to determine the gaseous ventilation rate.
Code of Federal Regulations, 2011 CFR
2011-07-01
... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Diesel Engines... engine to the dynamometer and attach the sampling and measurement devices specified in § 7.86. (2) A... zeroed and spanned at the analyzer range to be used prior to testing. (4) Run the engine. (i) The...
40 CFR 86.535-90 - Dynamometer procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... run consists of two tests, a “cold” start test and a “hot” start test following the “cold” start by 10... Administrator. (d) Practice runs over the prescribed driving schedule may be performed at test points, provided... the proper speed-time relationship, or to permit sampling system adjustments. (e) The drive wheel...
40 CFR 86.135-90 - Dynamometer procedure.
Code of Federal Regulations, 2012 CFR
2012-07-01
... startup and operation over the first 505 seconds of the driving schedule complete the hot start test. The... 505 seconds of the driving schedule complete the hot start test. The exhaust emissions are diluted... over the prescribed driving schedule may be performed at test point, provided an emission sample is not...
40 CFR 86.135-90 - Dynamometer procedure.
Code of Federal Regulations, 2013 CFR
2013-07-01
... startup and operation over the first 505 seconds of the driving schedule complete the hot start test. The... 505 seconds of the driving schedule complete the hot start test. The exhaust emissions are diluted... over the prescribed driving schedule may be performed at test point, provided an emission sample is not...
40 CFR 86.542-90 - Records required.
Code of Federal Regulations, 2010 CFR
2010-07-01
... dynamometer serial number, a reference to a vehicle test cell number may be used, with the advance approval of the Administrator, provided the test cell records show the pertinent instrument information. (h) All..., a reference to a vehicle test cell number may be used, with the advance approval of the...
40 CFR 86.108-00 - Dynamometer.
Code of Federal Regulations, 2010 CFR
2010-07-01
... load force and inertia specified for the vehicle being tested, and shall determine the distance... capable of dynamically controlling inertia load during the US06 test cycle as a function of a vehicle... equal to eight seconds, the test inertia load may be adjusted during any of five EPA specified...
40 CFR 86.336-79 - Diesel engine test cycle.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Diesel engine test cycle. 86.336-79 Section 86.336-79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Diesel engine test cycle. (a) The following 13-mode cycle shall be followed in dynamometer operation...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-30
... amendments to its evaporative emission test procedures, four-wheel drive dynamometer provisions, and vehicle... manufacturer has certified vehicles using an alternative running loss test procedure, CARB may conduct... manufacturer's approved alternative running loss test procedure; (3) provide manufacturers an option to use an...
40 CFR 86.537-90 - Dynamometer test runs.
Code of Federal Regulations, 2010 CFR
2010-07-01
... phase of the test. Obtain methanol and formaldehyde sample analyses, if applicable, within 24 hours of... minutes of the end of the sample collection phase of the test. Obtain methanol and formaldehyde sample... the dilute exhaust and dilution air sample collection systems. (4) For methanol-fueled vehicles, with...
40 CFR 86.537-90 - Dynamometer test runs.
Code of Federal Regulations, 2011 CFR
2011-07-01
... phase of the test. Obtain methanol and formaldehyde sample analyses, if applicable, within 24 hours of... minutes of the end of the sample collection phase of the test. Obtain methanol and formaldehyde sample... the dilute exhaust and dilution air sample collection systems. (4) For methanol-fueled vehicles, with...
40 CFR 86.108-00 - Dynamometer.
Code of Federal Regulations, 2011 CFR
2011-07-01
... load force and inertia specified for the vehicle being tested, and shall determine the distance... capable of dynamically controlling inertia load during the US06 test cycle as a function of a vehicle... equal to eight seconds, the test inertia load may be adjusted during any of five EPA specified...
40 CFR 86.108-00 - Dynamometer.
Code of Federal Regulations, 2013 CFR
2013-07-01
... load force and inertia specified for the vehicle being tested, and shall determine the distance... capable of dynamically controlling inertia load during the US06 test cycle as a function of a vehicle... equal to eight seconds, the test inertia load may be adjusted during any of five EPA specified...
40 CFR 86.108-00 - Dynamometer.
Code of Federal Regulations, 2014 CFR
2014-07-01
... load force and inertia specified for the vehicle being tested, and shall determine the distance... capable of dynamically controlling inertia load during the US06 test cycle as a function of a vehicle... equal to eight seconds, the test inertia load may be adjusted during any of five EPA specified...
40 CFR 86.108-00 - Dynamometer.
Code of Federal Regulations, 2012 CFR
2012-07-01
... load force and inertia specified for the vehicle being tested, and shall determine the distance... capable of dynamically controlling inertia load during the US06 test cycle as a function of a vehicle... equal to eight seconds, the test inertia load may be adjusted during any of five EPA specified...
Relation between functional mobility and dynapenia in institutionalized frail elderly.
Soares, Antonio Vinicius; Marcelino, Elessandra; Maia, Késsia Cristina; Borges, Noé Gomes
2017-01-01
To investigate the relation between functional mobility and dynapenia in institutionalized frail elderly. A descriptive, correlational study involving 26 institutionalized elderly men and women, mean age 82.3±6 years. The instruments employed were the Mini Mental State Examination, the Geriatric Depression Scale, the International Physical Activity Questionnaire, the Timed Up and Go test, a handgrip dynamometer and a portable dynamometer for large muscle groups (shoulder, elbow and hip flexors, knee extensors and ankle dorsiflexors). Significant negative correlation between functional mobility levels assessed by the Timed Up and Go test and dynapenia was observed in all muscle groups evaluated, particularly in knee extensors (r -0.65). A significant negative correlation between muscle strength, particularly knee extensor strength, and functional mobility was found in institutionalized elderly. Data presented indicate that the higher the muscle strength, the shorter the execution time, and this could demonstrate better performance in this functional mobility test.
Modeling transit bus fuel consumption on the basis of cycle properties.
Delgado, Oscar F; Clark, Nigel N; Thompson, Gregory J
2011-04-01
A method exists to predict heavy-duty vehicle fuel economy and emissions over an "unseen" cycle or during unseen on-road activity on the basis of fuel consumption and emissions data from measured chassis dynamometer test cycles and properties (statistical parameters) of those cycles. No regression is required for the method, which relies solely on the linear association of vehicle performance with cycle properties. This method has been advanced and examined using previously published heavy-duty truck data gathered using the West Virginia University heavy-duty chassis dynamometer with the trucks exercised over limited test cycles. In this study, data were available from a Washington Metropolitan Area Transit Authority emission testing program conducted in 2006. Chassis dynamometer data from two conventional diesel buses, two compressed natural gas buses, and one hybrid diesel bus were evaluated using an expanded driving cycle set of 16 or 17 different driving cycles. Cycle properties and vehicle fuel consumption measurements from three baseline cycles were selected to generate a linear model and then to predict unseen fuel consumption over the remaining 13 or 14 cycles. Average velocity, average positive acceleration, and number of stops per distance were found to be the desired cycle properties for use in the model. The methodology allowed for the prediction of fuel consumption with an average error of 8.5% from vehicles operating on a diverse set of chassis dynamometer cycles on the basis of relatively few experimental measurements. It was found that the data used for prediction should be acquired from a set that must include an idle cycle along with a relatively slow transient cycle and a relatively high speed cycle. The method was also applied to oxides of nitrogen prediction and was found to have less predictive capability than for fuel consumption with an average error of 20.4%.
40 CFR 89.410 - Engine test cycle.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine test cycle. 89.410 Section 89... Procedures § 89.410 Engine test cycle. (a) Emissions shall be measured using one of the test cycles specified...) through (a)(4) of this section. These cycles shall be used to test engines on a dynamometer. (1) The 8...
AMMONIA EMISSIONS FROM THE EPA'S LIGHT DUTY TEST VEHICLE
The paper discusses measurements of ammonia (NH3) emissions from EPA's light duty test vehicle while operated on a dynamometer. The vehicle's (1993 Chevrolet equipped with a three-way catalyst) emissions were measured for three transient (urban driving, highway fuel economy, and ...
Baltzopoulos, Vasilios; Richards, Paula J.; Maganaris, Constantinos N.
2011-01-01
The purpose of this study was to determine the effect of dynamometer and joint axis misalignment on measured isometric knee-extension moments using inverse dynamics based on the actual joint kinematic information derived from the real-time X-ray video and to compare the errors when the moments were calculated using measurements from external anatomical surface markers or obtained from the isokinetic dynamometer. Six healthy males participated in this study. They performed isometric contractions at 90° and 20° of knee flexion, gradually increasing to maximum effort. For the calculation of the actual knee-joint moment and the joint moment relative to the knee-joint center, determined using the external marker, two free body diagrams were used of the Cybex arm and the lower leg segment system. In the first free body diagram, the mean center of the circular profiles of the femoral epicondyles was used as the knee-joint center, whereas in the second diagram, the joint center was assumed to coincide with the external marker. Then, the calculated knee-joint moments were compared with those measured by the dynamometer. The results indicate that 1) the actual knee-joint moment was different from the dynamometer recorded moment (difference ranged between 1.9% and 4.3%) and the moment calculated using the skin marker (difference ranged between 2.5% and 3%), and 2) during isometric knee extension, the internal knee angle changed significantly from rest to the maximum contraction state by about 19°. Therefore, these differences cannot be neglected if the moment–knee-joint angle relationship or the muscle mechanical properties, such as length-tension relationship, need to be determined. PMID:21474701
40 CFR 91.404 - Test procedure overview.
Code of Federal Regulations, 2014 CFR
2014-07-01
... conducted on an engine dynamometer or equivalent load and speed measurement device. The exhaust gases... with an exponential relationship between torque and speed which span the typical operating range of...
Performance characteristics of the Kin-Com dynamometer.
Mayhew, T P; Rothstein, J M; Finucane, S D; Lamb, R L
1994-11-01
The purpose of this study was to assess the performance characteristics of a Kin-Com dynamometer (model #500-11) under controlled conditions. Comparisons were made between measurements of force, angle, and velocity obtained from the Kin-Com and measurements acquired from an external recording system of known weights, angles, and user-set velocities. The strength of the linear relationships between measurements obtained with the different recording systems was analyzed using a coefficient of determination (r2). An intraclass correlation coefficient (ICC[2,1]) was used to examine the reliability of the force, angle, and velocity measurements obtained with each recording system on 2 different days. In all conditions, the coefficient of determination for the force, angle, and velocity comparisons was above .99. The ICC for between-day comparisons for all force, angle, and velocity measurements was above .99. Our results indicate that the static measurements of force and angle that are necessary for use in the gravity-correction procedure and isometric testing are accurate and replicable between days. The Kin-Com dynamometer's control system regulating lever arm velocity is also accurate and replicable under a no-load condition. It was ascertained during the velocity testing that the use of any acceleration and deceleration mode other than "high" resulted in a loss of excursion of the lever arm.
40 CFR 91.404 - Test procedure overview.
Code of Federal Regulations, 2013 CFR
2013-07-01
... to be conducted on an engine dynamometer or equivalent load and speed measurement device. The exhaust... four power modes with an exponential relationship between torque and speed which span the typical...
40 CFR 91.404 - Test procedure overview.
Code of Federal Regulations, 2012 CFR
2012-07-01
... to be conducted on an engine dynamometer or equivalent load and speed measurement device. The exhaust... four power modes with an exponential relationship between torque and speed which span the typical...
40 CFR 90.404 - Test procedure overview.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust... engine operating conditions to be conducted on an engine dynamometer or equivalent load and speed... also designed to determine the brake-specific emissions of non-methane hydrocarbons. The test consists...
40 CFR 90.404 - Test procedure overview.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust... engine operating conditions to be conducted on an engine dynamometer or equivalent load and speed... also designed to determine the brake-specific emissions of non-methane hydrocarbons. The test consists...
40 CFR 90.404 - Test procedure overview.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust... engine operating conditions to be conducted on an engine dynamometer or equivalent load and speed... also designed to determine the brake-specific emissions of non-methane hydrocarbons. The test consists...
40 CFR 90.404 - Test procedure overview.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust... engine operating conditions to be conducted on an engine dynamometer or equivalent load and speed... also designed to determine the brake-specific emissions of non-methane hydrocarbons. The test consists...
40 CFR 86.237-94 - Dynamometer test run, gaseous emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... approximately 7.5 miles (12.1 kilometers) and a hot start drive of approximately 3.6 miles (5.8 kilometers). (b... and hot start test. The cold start test is divided into two periods. The first period, representing..., consists of the remainder of the driving schedule, including engine shutdown. The hot start test is...
40 CFR 86.237-94 - Dynamometer test run, gaseous emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... approximately 7.5 miles (12.1 kilometers) and a hot start drive of approximately 3.6 miles (5.8 kilometers). (b... and hot start test. The cold start test is divided into two periods. The first period, representing..., consists of the remainder of the driving schedule, including engine shutdown. The hot start test is...
40 CFR 86.237-94 - Dynamometer test run, gaseous emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... approximately 7.5 miles (12.1 kilometers) and a hot start drive of approximately 3.6 miles (5.8 kilometers). (b... and hot start test. The cold start test is divided into two periods. The first period, representing..., consists of the remainder of the driving schedule, including engine shutdown. The hot start test is...
40 CFR 86.340-79 - Gasoline-fueled engine dynamometer test run.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Observe pre-test procedures; § 86.339; (3) Start cooling system; (4) Start engine and operate in... be 5 minutes ±30 seconds. Sample flow may begin during the warm-up; (5) Read and record all pre-test... test run. 86.340-79 Section 86.340-79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...
40 CFR 86.340-79 - Gasoline-fueled engine dynamometer test run.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Observe pre-test procedures; § 86.339; (3) Start cooling system; (4) Start engine and operate in... be 5 minutes ±30 seconds. Sample flow may begin during the warm-up; (5) Read and record all pre-test... test run. 86.340-79 Section 86.340-79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...
40 CFR 86.340-79 - Gasoline-fueled engine dynamometer test run.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Observe pre-test procedures; § 86.339; (3) Start cooling system; (4) Start engine and operate in... be 5 minutes ±30 seconds. Sample flow may begin during the warm-up; (5) Read and record all pre-test... test run. 86.340-79 Section 86.340-79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...
40 CFR 86.340-79 - Gasoline-fueled engine dynamometer test run.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Observe pre-test procedures; § 86.339; (3) Start cooling system; (4) Start engine and operate in... be 5 minutes ±30 seconds. Sample flow may begin during the warm-up; (5) Read and record all pre-test... test run. 86.340-79 Section 86.340-79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...
40 CFR 1039.510 - Which duty cycles do I use for transient testing?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Which duty cycles do I use for... ENGINES Test Procedures § 1039.510 Which duty cycles do I use for transient testing? (a) Measure emissions by testing the engine on a dynamometer with one of the following transient duty cycles to determine...
21 CFR 888.1250 - Nonpowered dynamometer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonpowered dynamometer. 888.1250 Section 888.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1250 Nonpowered dynamometer. (a...
21 CFR 888.1250 - Nonpowered dynamometer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nonpowered dynamometer. 888.1250 Section 888.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1250 Nonpowered dynamometer. (a...
21 CFR 888.1250 - Nonpowered dynamometer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nonpowered dynamometer. 888.1250 Section 888.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1250 Nonpowered dynamometer. (a...
21 CFR 888.1250 - Nonpowered dynamometer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonpowered dynamometer. 888.1250 Section 888.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1250 Nonpowered dynamometer. (a...
21 CFR 888.1250 - Nonpowered dynamometer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nonpowered dynamometer. 888.1250 Section 888.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1250 Nonpowered dynamometer. (a...
40 CFR 86.235-94 - Dynamometer procedure.
Code of Federal Regulations, 2011 CFR
2011-07-01
... over the prescribed driving schedule may be performed at test point for the purpose of finding the... make a complete cold start test. Engine startup and operation over the first 505 seconds of the driving... preselectable power settings may be set anytime prior to the beginning of the emission test. (g) The driving...
40 CFR 86.235-94 - Dynamometer procedure.
Code of Federal Regulations, 2012 CFR
2012-07-01
... over the prescribed driving schedule may be performed at test point for the purpose of finding the... make a complete cold start test. Engine startup and operation over the first 505 seconds of the driving... preselectable power settings may be set anytime prior to the beginning of the emission test. (g) The driving...
40 CFR 86.235-94 - Dynamometer procedure.
Code of Federal Regulations, 2013 CFR
2013-07-01
... over the prescribed driving schedule may be performed at test point for the purpose of finding the... make a complete cold start test. Engine startup and operation over the first 505 seconds of the driving... preselectable power settings may be set anytime prior to the beginning of the emission test. (g) The driving...
40 CFR 86.137-94 - Dynamometer test run, gaseous and particulate emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... within 20 minutes of the end of the sample collection phase of the test. Obtain methanol and formaldehyde... the sample collection phase of the test. Obtain methanol and formaldehyde sample analyses, if... methanol-fueled vehicles, with the sample selector valves in the “standby” position, insert fresh sample...
40 CFR 86.137-94 - Dynamometer test run, gaseous and particulate emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... within 20 minutes of the end of the sample collection phase of the test. Obtain methanol and formaldehyde... the sample collection phase of the test. Obtain methanol and formaldehyde sample analyses, if... methanol-fueled vehicles, with the sample selector valves in the “standby” position, insert fresh sample...
Blade Testing Trends (Presentation)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Desmond, M.
2014-08-01
As an invited guest speaker, Michael Desmond presented on NREL's NWTC structural testing methods and capabilities at the 2014 Sandia Blade Workshop held on August 26-28, 2014 in Albuquerque, NM. Although dynamometer and field testing capabilities were mentioned, the presentation focused primarily on wind turbine blade testing, including descriptions and capabilities for accredited certification testing, historical methodology and technology deployment, and current research and development activities.
Schache, Margaret B; McClelland, Jodie A; Webster, Kate E
2016-01-01
To investigate the test-retest reliability of measuring hip abductor strength in patients with total knee arthroplasty (TKA) using a hand-held dynamometer (HHD) with two different types of resistance: belt and manual resistance. Test-retest reliability of 30 subjects (17 female, 13 male, 71.9 ± 7.4 years old), 9.2 ± 2.7 days post TKA was measured using belt and therapist resistance. Retest reliability was calculated with intra-class coefficients (ICC3,1) and 95% confidence intervals (CI) for both the group average and the individual scores. A paired t-test assessed whether a difference existed between the belt and therapist methods of resistance. ICCs were 0.82 and 0.80 for the belt and therapist resisted methods, respectively. Hip abductor strength increases of 8 N (14%) for belt resisted and 14 N (17%) for therapist resisted measurements of the group average exceeded the 95% CI and may represent real change. For individuals, hip abductor strength increases of 33 N (72%) (belt resisted) and 57 N (79%) (therapist resisted) could be interpreted as real change. Hip abductor strength can be reliably measured using HHD in the clinical setting with the described protocol. Belt resistance demonstrated slightly higher test-retest reliability. Reliable measurement of hip abductor muscle strength in patients with TKA is important to ensure deficiencies are addressed in rehabilitation programs and function is maximized. Hip abductor strength can be reliably measured with a hand-held dynamometer in the clinical setting using manual or belt resistance.
40 CFR 1066.210 - Dynamometers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... to recreate the mechanical inertia and frictional forces that a vehicle exerts on road surfaces... drive axles may share a single drive roll. Use good engineering judgment to ensure that the dynamometer... engineering judgment. (3) The load applied by the dynamometer simulates forces acting on the vehicle during...
40 CFR 86.535-90 - Dynamometer procedure.
Code of Federal Regulations, 2014 CFR
2014-07-01
... minutes. Engine startup (with all accessories turned off), operation over the driving schedule, and engine... driving schedule complete the hot start test. The exhaust emissions are diluted with ambient air and a... Administrator. (d) Practice runs over the prescribed driving schedule may be performed at test points, provided...
40 CFR 86.535-90 - Dynamometer procedure.
Code of Federal Regulations, 2011 CFR
2011-07-01
... minutes. Engine startup (with all accessories turned off), operation over the driving schedule, and engine... driving schedule complete the hot start test. The exhaust emissions are diluted with ambient air and a... Administrator. (d) Practice runs over the prescribed driving schedule may be performed at test points, provided...
40 CFR 86.535-90 - Dynamometer procedure.
Code of Federal Regulations, 2012 CFR
2012-07-01
... minutes. Engine startup (with all accessories turned off), operation over the driving schedule, and engine... driving schedule complete the hot start test. The exhaust emissions are diluted with ambient air and a... Administrator. (d) Practice runs over the prescribed driving schedule may be performed at test points, provided...
40 CFR 86.535-90 - Dynamometer procedure.
Code of Federal Regulations, 2013 CFR
2013-07-01
... minutes. Engine startup (with all accessories turned off), operation over the driving schedule, and engine... driving schedule complete the hot start test. The exhaust emissions are diluted with ambient air and a... Administrator. (d) Practice runs over the prescribed driving schedule may be performed at test points, provided...
40 CFR 85.2230 - Steady state test dynamometer-EPA 91.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM MOBILE SOURCES Emission Control System Performance... applicability. The requirements of § 85.2229 apply concurrently for tests conducted under Emission Performance... capable of applying a load to the vehicle's driving tire surfaces at the horsepower and speed levels...
40 CFR 1066.245 - Response time verification.
Code of Federal Regulations, 2013 CFR
2013-07-01
... dynamometer's automated process to verify response time. Perform this test at two different inertia settings... observed settling response time must be less than 100 milliseconds for each inertia setting. ER15SE11.085 ...
40 CFR 1066.245 - Response time verification.
Code of Federal Regulations, 2012 CFR
2012-07-01
... dynamometer's automated process to verify response time. Perform this test at two different inertia settings... observed settling response time must be less than 100 milliseconds for each inertia setting. ER15SE11.085 ...
Dobbin, Nick; Hunwicks, Richard; Jones, Ben; Till, Kevin; Highton, Jamie; Twist, Craig
2018-02-01
To examine the criterion and construct validity of an isometric midthigh-pull dynamometer to assess whole-body strength in professional rugby league players. Fifty-six male rugby league players (33 senior and 23 youth players) performed 4 isometric midthigh-pull efforts (ie, 2 on the dynamometer and 2 on the force platform) in a randomized and counterbalanced order. Isometric peak force was underestimated (P < .05) using the dynamometer compared with the force platform (95% LoA: -213.5 ± 342.6 N). Linear regression showed that peak force derived from the dynamometer explained 85% (adjusted R 2 = .85, SEE = 173 N) of the variance in the dependent variable, with the following prediction equation derived: predicted peak force = [1.046 × dynamometer peak force] + 117.594. Cross-validation revealed a nonsignificant bias (P > .05) between the predicted and peak force from the force platform and an adjusted R 2 (79.6%) that represented shrinkage of 0.4% relative to the cross-validation model (80%). Peak force was greater for the senior than the youth professionals using the dynamometer (2261.2 ± 222 cf 1725.1 ± 298.0 N, respectively; P < .05). The isometric midthigh pull assessed using a dynamometer underestimates criterion peak force but is capable of distinguishing muscle-function characteristics between professional rugby league players of different standards.
21 CFR 888.1240 - AC-powered dynamometer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false AC-powered dynamometer. 888.1240 Section 888.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1240 AC-powered dynamometer. (a...
21 CFR 888.1240 - AC-powered dynamometer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false AC-powered dynamometer. 888.1240 Section 888.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1240 AC-powered dynamometer. (a...
21 CFR 888.1240 - AC-powered dynamometer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false AC-powered dynamometer. 888.1240 Section 888.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1240 AC-powered dynamometer. (a...
40 CFR 86.333-79 - Dynamometer calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... master load-cell for each in-use range used. (5) The in-use torque measurement must be within 2 percent... basic operating adjustments. (b) Check the dynamometer torque measurement for each range used by the following: (1) Warm up the dynamometer following the equipment manufacturer's specifications. (2) Determine...
40 CFR 86.1237-96 - Dynamometer runs.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Dynamometer runs. 86.1237-96 Section 86.1237-96 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Methanol-Fueled Heavy-Duty Vehicles § 86.1237-96 Dynamometer runs. Section 86.1237-96 includes text that...
40 CFR 86.1237-96 - Dynamometer runs.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Dynamometer runs. 86.1237-96 Section 86.1237-96 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Methanol-Fueled Heavy-Duty Vehicles § 86.1237-96 Dynamometer runs. Section 86.1237-96 includes text that...
40 CFR 1066.270 - Unloaded coastdown verification.
Code of Federal Regulations, 2014 CFR
2014-07-01
... manufacturer. (2) With the dynamometer in coastdown mode, set the dynamometer inertia for the smallest vehicle...)(2) of this section with the dynamometer inertia and road-load coefficients set for the largest... inertia setting for each of the coastdowns performed using the following equation: ER28AP14.078 Where: F...
Generation and characterization of diesel exhaust in a facility for controlled human exposures
An idling medium-duty diesel truck operated on ultralow sulfur diesel fuel was used as an emission source to generate diesel exhaust for controlled human exposure. Repeat tests were conducted on the Federal Test Procedure using a chassis dynamometer to demonstrate the reproducibi...
40 CFR 89.401 - Scope; applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... subpart B of this part. (b) Exhaust gases, either raw or dilute, are sampled while the test engine is operated using the appropriate test cycle on an engine dynamometer. The exhaust gases receive specific... the power output during each mode. Emissions are reported as grams per kilowatt hour (g/kW-hr). (c...
40 CFR 89.404 - Test procedure overview.
Code of Federal Regulations, 2010 CFR
2010-07-01
... engine operating conditions to be conducted on an engine dynamometer. The exhaust gases, generated raw or... matter. For more information on particulate matter sampling see § 89.112(c). The test cycles consist of... (raw analysis), and the power output during each mode. The measured values are weighted and used to...
40 CFR 89.301 - Scope; applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... subpart B of part 89. (b) Exhaust gases, either raw or dilute, are sampled while the test engine is operated using an 8-mode test cycle on an engine dynamometer. The exhaust gases receive specific component analysis determining concentration of pollutant, exhaust volume, the fuel flow, and the power output during...
40 CFR 90.301 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the test engine is operated using a steady state test cycle on an engine dynamometer. The exhaust... concentrations are converted to mass emission rates in grams per hour based on either fuel flow, fuel flow and engine intake air flow, or exhaust volume flow. Weighted emission rates are reported as grams per brake...
Research Facilities | Wind | NREL
wearing hard hats in front of a wind turbine drivetrain inside a drivetrain test facility. Dynamometer Research Facilities Photo of five men in hard hards observing the end of a turbine blade while it's being
Energy Systems Integration News | Energy Systems Integration Facility |
photovoltaic (PV) energy for its power. PV inverter hardware-in the loop testing was conducted at NREL's Energy -scale power-hardware-in-the-loop testing at the ESIF, which allows researchers and manufacturers to test field. In addition, the CGI provides hardware-in-the-loop capability combined with NWTC dynamometers
40 CFR 1048.510 - What transient duty cycles apply for laboratory testing?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What transient duty cycles apply for... Procedures § 1048.510 What transient duty cycles apply for laboratory testing? (a) Starting with the 2007 model year, measure emissions by testing the engine on a dynamometer with the duty cycle described in...
Reliability and validity of the closed kinetic chain upper extremity stability test.
Lee, Dong-Rour; Kim, Laurentius Jongsoon
2015-04-01
[Purpose] The purpose of this study was to examine the reliability and validity of the Closed Kinetic Chain Upper Extremity Stability (CKCUES) test. [Subjects and Methods] A sample of 40 subjects (20 males, 20 females) with and without pain in the upper limbs was recruited. The subjects were tested twice, three days apart to assess the reliability of the CKCUES test. The CKCUES test was performed four times, and the average was calculated using the data of the last 3 tests. In order to test the validity of the CKCUES test, peak torque of internal/external shoulder rotation was measured using an isokinetic dynamometer, and maximum grip strength was measured using a hand dynamometer, and their Pearson correlation coefficients with the average values of the CKCUES test were calculated. [Results] The reliability of the CKCUES test was very high (ICC=0.97). The correlations between the CKCUES test and maximum grip strength (r=0.78-0.79), and the peak torque of internal/external shoulder rotation (r=0.87-0.94) were high indicating its validity. [Conclusion] The reliability and validity of the CKCUES test were high. The CKCUES test is expected to be used for clinical tests on upper limb stability at low price.
40 CFR 91.306 - Dynamometer torque cell calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Dynamometer torque cell calibration... Provisions § 91.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used to convert a weight or a... with the adjusted or repaired system. (b) Option. A master load-cell or transfer standard may be used...
40 CFR 91.306 - Dynamometer torque cell calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Dynamometer torque cell calibration... Provisions § 91.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used to convert a weight or a... with the adjusted or repaired system. (b) Option. A master load-cell or transfer standard may be used...
40 CFR 91.306 - Dynamometer torque cell calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Dynamometer torque cell calibration... Provisions § 91.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used to convert a weight or a... with the adjusted or repaired system. (b) Option. A master load-cell or transfer standard may be used...
40 CFR 91.306 - Dynamometer torque cell calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Dynamometer torque cell calibration... Provisions § 91.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used to convert a weight or a... with the adjusted or repaired system. (b) Option. A master load-cell or transfer standard may be used...
40 CFR 90.306 - Dynamometer torque cell calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Dynamometer torque cell calibration. 90... Equipment Provisions § 90.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used to convert a... (a)(6) of this section with the adjusted or repaired system. (b) Option. A master load-cell or...
40 CFR 91.306 - Dynamometer torque cell calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Dynamometer torque cell calibration. 91....306 Dynamometer torque cell calibration. (a)(1) Any lever arm used to convert a weight or a force... with the adjusted or repaired system. (b) Option. A master load-cell or transfer standard may be used...
Relation between functional mobility and dynapenia in institutionalized frail elderly
Soares, Antonio Vinicius; Marcelino, Elessandra; Maia, Késsia Cristina; Borges, Noé Gomes
2017-01-01
ABSTRACT Objective To investigate the relation between functional mobility and dynapenia in institutionalized frail elderly. Methods A descriptive, correlational study involving 26 institutionalized elderly men and women, mean age 82.3±6 years. The instruments employed were the Mini Mental State Examination, the Geriatric Depression Scale, the International Physical Activity Questionnaire, the Timed Up and Go test, a handgrip dynamometer and a portable dynamometer for large muscle groups (shoulder, elbow and hip flexors, knee extensors and ankle dorsiflexors). Results Significant negative correlation between functional mobility levels assessed by the Timed Up and Go test and dynapenia was observed in all muscle groups evaluated, particularly in knee extensors (r -0.65). Conclusion A significant negative correlation between muscle strength, particularly knee extensor strength, and functional mobility was found in institutionalized elderly. Data presented indicate that the higher the muscle strength, the shorter the execution time, and this could demonstrate better performance in this functional mobility test. PMID:29091148
Toyota's inspection system for vehicular emissions at assembly lines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanaka, T.; Nakano, H.; Usami, I.
1976-01-01
In order that all Toyota production vehicles may satisfy the emission requirements and be free from possible defects such as catalytic converter damage, a system called ECAS, which allows us to assure satisfactory basic emission performance levels has been developed and put into actual use at assembly lines. This system consists of the following four tests: Idle Test, Functional Test, Short Cycle Test and Steady State Inspection Test. By using this system, all operations from vehicle setup, on a chassis dynamometer to statistical analysis of the data, measurement, judgement of the obtained data, type-out of the results, indication for actionmore » to be taken, data filing and statistical treatment of the data, are processed automatically and controlled by the computer. In the Short Cycle Test the up-stream emissions of the vehicle, tracing Toyota's unique short cyclic mode on a chassis dynamometer, are continuously measured. Based on the emission levels during each mode and the total emission level obtained from the above test we can diagnose, not only the emission control systems of a vehicle and its engine conditions such as valve clearance maladjustment and carburetor defects, but also the emission characteristics of this vehicle.« less
Statistics of indicated pressure in combustion engine.
NASA Astrophysics Data System (ADS)
Sitnik, L. J.; Andrych-Zalewska, M.
2016-09-01
The paper presents the classic form of pressure waveforms in burn chamber of diesel engine but based on strict analytical basis for amending the displacement volume. The pressure measurement results are obtained in the engine running on an engine dynamometer stand. The study was conducted by a 13-phase ESC test (European Stationary Cycle). In each test phase are archived 90 waveforms of pressure. As a result of extensive statistical analysis was found that while the engine is idling distribution of 90 value of pressure at any value of the angle of rotation of the crankshaft can be described uniform distribution. In the each point of characteristic of the engine corresponding to the individual phases of the ESC test, 90 of the pressure for any value of the angle of rotation of the crankshaft can be described as normal distribution. These relationships are verified using tests: Shapiro-Wilk, Jarque-Bera, Lilliefors, Anderson-Darling. In the following part, with each value of the crank angle, are obtain values of descriptive statistics for the pressure data. In its essence, are obtained a new way to approach the issue of pressure waveform analysis in the burn chamber of engine. The new method can be used to further analysis, especially the combustion process in the engine. It was found, e.g. a very large variances of pressure near the transition from compression to expansion stroke. This lack of stationarity of the process can be important both because of the emissions of exhaust gases and fuel consumption of the engine.
40 CFR 86.135-00 - Dynamometer procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... see § 86.135-90. (d) Practice runs over the prescribed driving schedule may be performed at test point...; the rocking of the vehicle changes the tire rolling radius on each roll. This rocking may be minimized...
KEEVIL, VICTORIA L.; COOPER, ANDREW J. M.; WIJNDAELE, KATRIEN; LUBEN, ROBERT; WAREHAM, NICHOLAS J.; BRAGE, SOREN; KHAW, KAY-TEE
2016-01-01
ABSTRACT Purpose Sedentariness has been proposed as an independent risk factor for poor health. However, few studies have considered associations of sedentary time (ST) with physical functional health independent of time spent in moderate-to-vigorous physical activity (MVPA). Methods Community-based men and women (n = 8623, 48–92 yr old) in the European Prospective Investigation of Cancer—Norfolk study attended a health examination for objective measurement of physical capability, including grip strength (Smedley dynamometer (kg)), usual walking speed (UWS (cm·s−1)), and timed chair stand speed (TCSS (stands per minute)). Of these, 4051 participants wore an accelerometer (GT1M ActiGraph) for 7 d to estimate time spent in MVPA (MVPA, ≥1952 counts per minute) and ST (ST, <100 counts per minute). Relations between physical capability outcomes and both MVPA and ST were explored using linear regression. The mutual independence of associations was also tested, and ST-MVPA interactions were explored using fractional polynomial models to account for nonlinear associations. Results Men in the highest compared with those in the lowest sex-specific quartile of MVPA were stronger (1.84 kg; 95% confidence interval (CI), 0.79–2.89), had faster UWS (11.7 cm·s−1; 95% CI, 8.4–15.1) and faster TCSS (2.35 stands per minute; 95% CI, 1.11–3.59) after multivariable adjustment. Similarly, women in the highest quartile of MVPA were stronger (2.47 kg; 95% CI, 1.79–3.14) and had faster UWS (15.5 cm·s−1; 95% CI, 12.4–18.6) and faster TCSS (3.27 stands per minute; 95% CI, 2.19–4.25). Associations persisted after further adjustment for ST. Associations between higher ST and lower physical capability were also observed, but these were attenuated after accounting for MVPA. Furthermore, no MVPA–ST interactions were observed (Pinteractions > 0.05). Conclusions More time spent in MVPA was associated with higher physical capability, but there were no independent ST associations. PMID:26501232
40 CFR 86.1215-85 - EPA heavy-duty vehicle (HDV) urban dynamometer driving schedule.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 19 2010-07-01 2010-07-01 false EPA heavy-duty vehicle (HDV) urban..., Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.1215-85 EPA heavy-duty vehicle (HDV) urban dynamometer driving schedule. (a)(1) The EPA dynamometer driving schedule for heavy-duty...
Cold Temperature Effects on Speciated VOC Emissions from Modern GDI Light-Duty Vehicles 1
In this study, speciated VOC emissions were characterized from three modern GDI light-duty vehicles. The vehicles were tested on a chassis dynamometer housed in a climate-controlled chamber at two temperatures (20 and 72 °F) using the EPA Federal Test Procedure (FTP) and a portio...
40 CFR 86.334-79 - Test procedure overview.
Code of Federal Regulations, 2010 CFR
2010-07-01
... cycle and 1 hot cycle. The Diesel engine test consists of 3 idle modes and 5 power modes at each of 2... to be conducted on an engine dynamometer. The exhaust gases generated during engine operation are... determination of the concentration of each pollutant, the fuel flow and the power output during each mode. The...
NAC Aftermarket Brake Components Project (Secondary Items)
2007-02-06
2. Appendix B. Test Plans and Sample Assignments for Disc Brake Pads and (Foundation) Drum Brake Shoes. 3. Appendix C. Test Plans and Sample...Assignments for Disc Brake Rotors and Drum Brake Drums . 4. Appendix D. Off-vehicle Inertia Dynamometer Test Procedures. 5. Appendix E. “Crack & Fatigue...apples” comparison testing processes, and require project outputs documents to be proofed by actual independent testing; HMMWV-ECV ( disc ) and HEMTT
Factors predicting dynamic balance and quality of life in home-dwelling elderly women.
Karinkanta, S; Heinonen, A; Sievanen, H; Uusi-Rasi, K; Kannus, P
2005-01-01
Proper balance seems to be a critical factor in terms of fall prevention among the elderly. The purpose of this cross-sectional study was to examine factors that are associated with dynamic balance and health-related quality of life in home-dwelling elderly women. One hundred and fifty-three healthy postmenopausal women (mean age: 72 years, height: 159 cm, weight: 72 kg) were examined. General health and physical activity were assessed by a questionnaire. Quality of life was measured using a health-related quality of life questionnaire (Rand 36-Item Health Survey 1.0). Dynamic balance (agility) was tested by a figure-of-eight running test. Static balance (postural sway) was tested on an unstable platform. Maximal isometric strength of the leg extensors was measured with a leg press dynamometer. Dynamic muscle strength of lower limbs was tested by measuring ground reaction forces with a force platform during common daily activities (sit-to-stand and step-on-a-stair tests). Concerning physical activity, 33% of the subjects reported brisk exercise (walking, Nordic walking, cross-country skiing, swimming and aquatic exercises) at least twice a week, and 22% some kind of brisk activity once a week in addition to lighter physical exercise. The remaining 45% did not exercise regularly and were classified as sedentary. The correlations of step-on-a-stair and sit-to-stand ground reaction forces, and leg extensor strength to dynamic balance were from -0.32 to -0.43 (the better the strength, the better the balance). In the regression analysis with backward elimination, step-on-a-stair and sit-to-stand ground reaction forces, and leg extensor strength, age, brisk physical activity, number of diseases and dynamic postural stability explained 42% of the variance in the dynamic balance. Similarly, dynamic balance (figure-of-eight running time), number of diseases and walking more than 3 km per day explained 14% of the variance in the quality of life score. Of these, figure-of-eight running time was the strongest predictor of the quality of life score, explaining 9% of its variance. This study emphasizes the concept that in home-dwelling elderly women good muscle strength in lower limbs is crucial for proper body balance and that dynamic balance is an independent predictor of a standardized quality of life estimate. The results provide important and useful information when planning meaningful contents for studies related to fall prevention and quality of life and interventions in elderly women. Copyright (c) 2005 S. Karger AG, Basel.
SPECIATED VOC EMISSIONS FROM MODERN GDI LIGHT DUTY VEHICLES
Chassis dynamometer emissions testing was conducted to characterize speciated volatile organic compounds (VOCs), including mobile source air toxics (MSATs) and ozone precursors, in exhaust emissions from three modern gasoline direct injection (GDI) light-duty vehicles. Each GDI v...
Performance Characteristics of 1977 Chrysler 318 CID Engine
DOT National Transportation Integrated Search
1980-02-01
Experimental data were obtained in dynamometer tests of a 1977 Chrysler 318 CID engine to determine fuel consumption and emissions (hydrocarbons, carbon monoxide, and oxides of nitrogen) at steady-state engine operating modes. The objective of the te...
Lean Mixture Engines Testing and Evaluation Program : Volume 3. Appendices.
DOT National Transportation Integrated Search
1975-01-01
This report is aimed at defining analytically and demonstrating experimentally the potential of the 'lean-burn concept.' Fuel consumption and emissions data are obtained on the engine dynamometer for the baseline engine, and two lean-burn configurati...
Silva, Rívea Trindade da; Câmara, Saionara Maria Aires da; Moreira, Mayle Andrade; Nascimento, Rafaela Andrade do; Vieira, Mariana Carmem Apolinário; Morais, Maria Socorro Medeiros de; Maciel, Álvaro Campos Cavalcanti
2016-06-01
Introduction Some studies have investigated the influence of hormonal deficits and menopausal status in muscle disorders of women. However, it has not been investigated the relationship of both climacteric symptoms and the perception of quality of life with physical performance. Objective To evaluate the correlation of menopausal symptoms and quality of life with physical performance in middle-aged women. Methods This cross-sectional study was performed from April to November 2013 in the municipality of Parnamirim, in the Brazilian state, Rio Grande do Norte. The sample was composed of 497 women aged 40-65 years. The Menopause Rating Scale (MRS) and the Utian Quality of Life (UQOL) questionnaire were used to evaluate menopausal symptoms and quality of life respectively. Measures of physical performance included handgrip strength, knee extensor and flexor strengths (using an isometric dynamometer), gait speed, and chair stand test. The correlation between menopausal symptoms and quality of life with physical performance was assessed by Pearson's correlation coefficient with significance set at p < 0.05 and a confidence interval of 95%. Results There was a significant negative correlation between handgrip strength and somatic MRS score (p = 0.002) and total MRS score (p = 0.03). There was a significant correlation between knee flexor strength and sit-to-stand time and all menopausal symptom areas (p < 0.05), except psychological symptoms. There was a positive correlation between physical performance of the knee flexors and quality of life items including occupational (p = 0.001), emotional (p = 0.005), and total UQOL (p = 0.01), but a negative correlation with sit-to-stand time and all quality of life domains (p < 0.05). Conclusion A greater intensity of menopausal symptoms and worse quality of life were related with worse physical performance. Thus, preventive measures should be implemented to avoid adverse effects on physical performance at more advanced ages. Thieme Publicações Ltda Rio de Janeiro, Brazil.
Romero-Franco, Natalia; Jiménez-Reyes, Pedro; Montaño-Munuera, Juan A
2017-11-01
Lower limb isometric strength is a key parameter to monitor the training process or recognise muscle weakness and injury risk. However, valid and reliable methods to evaluate it often require high-cost tools. The aim of this study was to analyse the concurrent validity and reliability of a low-cost digital dynamometer for measuring isometric strength in lower limb. Eleven physically active and healthy participants performed maximal isometric strength for: flexion and extension of ankle, flexion and extension of knee, flexion, extension, adduction, abduction, internal and external rotation of hip. Data obtained by the digital dynamometer were compared with the isokinetic dynamometer to examine its concurrent validity. Data obtained by the digital dynamometer from 2 different evaluators and 2 different sessions were compared to examine its inter-rater and intra-rater reliability. Intra-class correlation (ICC) for validity was excellent in every movement (ICC > 0.9). Intra and inter-tester reliability was excellent for all the movements assessed (ICC > 0.75). The low-cost digital dynamometer demonstrated strong concurrent validity and excellent intra and inter-tester reliability for assessing isometric strength in the main lower limb movements.
Component qualification and initial build of the AGT 100 advanced automotive gas turbine
NASA Technical Reports Server (NTRS)
Johnson, R. A.
1983-01-01
In advance of initial dynamometer testing of the AGT 100 engine, all prime components and subsystems were bench/rig tested. Included were compressor, combustor, turbines, regenerator, ceramic components, and electronic control system. Results are briefly reviewed. Initial engine buildup was completed and rolled-out for test cell installation in July 1982. Shakedown testing included motoring and sequential firing of the combustor's three fuel nozzles.
Lean Mixture Engines Testing and Evaluation Program : Volume 2. Comprehensive Discussion.
DOT National Transportation Integrated Search
1975-11-01
This report is aimed at defining analytically and demonstrating experimentally the potential of the 'lean-burn concept.' Fuel consumption and emissions data are obtained on the engine dynamometer for the baseline engine, and two lean-burn configurati...
Lean Mixture Engines Testing and Evaluation Program : Volume 1. Executive Summary.
DOT National Transportation Integrated Search
1975-01-01
This report is aimed at defining analytically and demonstrating experimentally the potential of the 'lean-burn concept'. Fuel consumption and emissions data are obtained on the engine dynamometer for the baseline engine, and two lean-burn configurati...
40 CFR 1048.510 - What transient duty cycles apply for laboratory testing?
Code of Federal Regulations, 2013 CFR
2013-07-01
... model year, measure emissions by testing the engine on a dynamometer with the duty cycle described in Appendix II to determine whether it meets the transient emission standards in § 1048.101(a). (b) Calculate cycle statistics and compare with the established criteria as specified in 40 CFR 1065.514 to confirm...
40 CFR 1048.510 - What transient duty cycles apply for laboratory testing?
Code of Federal Regulations, 2011 CFR
2011-07-01
... model year, measure emissions by testing the engine on a dynamometer with the duty cycle described in Appendix II to determine whether it meets the transient emission standards in § 1048.101(a). (b) Calculate cycle statistics and compare with the established criteria as specified in 40 CFR 1065.514 to confirm...
40 CFR 1048.510 - What transient duty cycles apply for laboratory testing?
Code of Federal Regulations, 2014 CFR
2014-07-01
... model year, measure emissions by testing the engine on a dynamometer with the duty cycle described in Appendix II to determine whether it meets the transient emission standards in § 1048.101(a). (b) Calculate cycle statistics and compare with the established criteria as specified in 40 CFR 1065.514 to confirm...
40 CFR 1048.510 - What transient duty cycles apply for laboratory testing?
Code of Federal Regulations, 2012 CFR
2012-07-01
... model year, measure emissions by testing the engine on a dynamometer with the duty cycle described in Appendix II to determine whether it meets the transient emission standards in § 1048.101(a). (b) Calculate cycle statistics and compare with the established criteria as specified in 40 CFR 1065.514 to confirm...
Laboratory Test of Reciprocating Internal Combustion Engines
2016-02-04
testing require extremely accurate fuel consumption measurement, and the ability to temperature condition the fuel. Most dynamometer manufacturers...include, but are not limited to, differences in fuels, lubrication, temperatures , engine control module parameters, component wear, exhaust, and air...exhaust gas recirculation (EGR) fuel consumption 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT SAR 18. NUMBER OF PAGES 38
40 CFR 1051.615 - What are the special provisions for certifying small recreational engines?
Code of Federal Regulations, 2010 CFR
2010-07-01
... dynamometer using the equipment and procedures of 40 CFR part 1065 with either discrete-mode or ramped-modal... discrete-mode and ramped-modal testing (either in your original application or in an amendment to your... by the Clean Air Act. Measure steady-state emissions as follows: (1) For discrete-mode testing...
Testing vehicles for emissions and fuel economy has traditionally been conducted with a single-axle chassis dynamometer. The 2006 SAE All Wheel Drive Symposium cited four wheel drive (4WD) and all wheel drive (AWD) sales as climbing from 20% toward 30% of a motor vehicle mar...
Jia, Zhenyuan; Jin, Lei; Liu, Wei; Ren, Zongjin
2016-01-01
Piezoelectric dynamometers are out of use in high humidity. Experimental results showed that piezoelectric coefficients measured by the force-induced charges method initially fluctuated in a small range and then was unstable, and they could not be measured at high relative humidity (RH). The traditional shielding method-insulation paste was not quiet convenient, and it even added the weight of piezoelectric dynamometers. In this paper, a novel strategy that eliminates the influence of water adsorption with quartz surfaces on piezoelectric dynamometers was proposed. First, a water-quartz model was developed to analyze the origin of the RH effect. In the model, water vapor, which was adsorbed by the quartz sheet side surface, was considered. Second, equivalent sheet resistor of the side surface was researched, while the relationship of the three R’s (Roughness, RH, and Resistor) was respectively discussed based on the adsorption mechanism. Finally, fluorination technology was skillfully adapted to each surface of quartz sheets to shield the water vapor. The experiment verified the fluorination strategy and made piezoelectric dynamometers work in high humidity up to 90%RH successfully. The results showed that the presented model above was reasonable. In addition, these observations also drew some useful insights to change the structure of piezoelectric dynamometers and improve the properties. PMID:27399719
40 CFR 610.64 - Track test procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... truck or trailer. (4) Fuel economy will be determined by either a gravimetric or volumetric method. (c... dynamometer except that fuel economy will be measured by gravimetric or volumetric methods. ... either a volumetric or gravimetric procedure approved by the Administrator. (5) Vehicle speed and...
ANALYSIS OF REAL-TIME VEHICLE HYDROCARBON EMISSIONS DATA
The report gives results of analyses using real-time dynamometer test emissions data from 13 passenger cars to examine variations in emissions during different speeds or modes of travel. The resulting data provided a way to separately identify idle, cruise, acceleration, and dece...
40 CFR 610.64 - Track test procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... truck or trailer. (4) Fuel economy will be determined by either a gravimetric or volumetric method. (c... dynamometer except that fuel economy will be measured by gravimetric or volumetric methods. ... either a volumetric or gravimetric procedure approved by the Administrator. (5) Vehicle speed and...
DOT National Transportation Integrated Search
2012-07-01
Microscopic models produce emissions and fuel consumption estimates with higher temporal resolution than other scales of : models. Most emissions and fuel consumption models were developed with data from dynamometer testing which are : sufficiently a...
40 CFR 1066.240 - Torque transducer verification.
Code of Federal Regulations, 2014 CFR
2014-07-01
... POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.240 Torque transducer verification. Verify torque-measurement systems by performing the verifications described in §§ 1066.270 and... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Torque transducer verification. 1066...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Overview. 1065.101 Section 1065.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING... equipment includes three broad categories-dynamometers, engine fluid systems (such as fuel and intake-air...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Overview. 1065.101 Section 1065.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING... equipment includes three broad categories-dynamometers, engine fluid systems (such as fuel and intake-air...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Overview. 1065.101 Section 1065.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING... equipment includes three broad categories-dynamometers, engine fluid systems (such as fuel and intake-air...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Overview. 1065.101 Section 1065.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING... equipment includes three broad categories-dynamometers, engine fluid systems (such as fuel and intake-air...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Overview. 1065.101 Section 1065.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING... equipment includes three broad categories-dynamometers, engine fluid systems (such as fuel and intake-air...
Evolutionary algorithm for vehicle driving cycle generation.
Perhinschi, Mario G; Marlowe, Christopher; Tamayo, Sergio; Tu, Jun; Wayne, W Scott
2011-09-01
Modeling transit bus emissions and fuel economy requires a large amount of experimental data over wide ranges of operational conditions. Chassis dynamometer tests are typically performed using representative driving cycles defined based on vehicle instantaneous speed as sequences of "microtrips", which are intervals between consecutive vehicle stops. Overall significant parameters of the driving cycle, such as average speed, stops per mile, kinetic intensity, and others, are used as independent variables in the modeling process. Performing tests at all the necessary combinations of parameters is expensive and time consuming. In this paper, a methodology is proposed for building driving cycles at prescribed independent variable values using experimental data through the concatenation of "microtrips" isolated from a limited number of standard chassis dynamometer test cycles. The selection of the adequate "microtrips" is achieved through a customized evolutionary algorithm. The genetic representation uses microtrip definitions as genes. Specific mutation, crossover, and karyotype alteration operators have been defined. The Roulette-Wheel selection technique with elitist strategy drives the optimization process, which consists of minimizing the errors to desired overall cycle parameters. This utility is part of the Integrated Bus Information System developed at West Virginia University.
Isometric hand grip strength measured by the Nintendo Wii Balance Board - a reliable new method.
Blomkvist, A W; Andersen, S; de Bruin, E D; Jorgensen, M G
2016-02-03
Low hand grip strength is a strong predictor for both long-term and short-term disability and mortality. The Nintendo Wii Balance Board (WBB) is an inexpensive, portable, wide-spread instrument with the potential for multiple purposes in assessing clinically relevant measures including muscle strength. The purpose of the study was to explore intrarater reliability and concurrent validity of the WBB by comparing it to the Jamar hand dynamometer. Intra-rater test-retest cohort design with randomized validity testing on the first session. Using custom WBB software, thirty old adults (69.0 ± 4.2 years of age) were studied for reproducibility and concurrent validity compared to the Jamar hand dynamometer. Reproducibility was tested for dominant and non-dominant hands during the same time-of-day, one week apart. Intraclass correlation coefficient (ICC) and standard error of measurement (SEM) and limits of agreement (LOA) were calculated to describe relative and absolute reproducibility respectively. To describe concurrent validity, Pearson's product-moment correlation and ICC was calculated. Reproducibility was high with ICC values of >0.948 across all measures. Both SEM and LOA were low (0.2-0.5 kg and 2.7-4.2 kg, respectively) in both the dominant and non-dominant hand. For validity, Pearson correlations were high (0.80-0.88) and ICC values were fair to good (0.763-0.803). Reproducibility for WBB was high for relative measures and acceptable for absolute measures. In addition, concurrent validity between the Jamar hand dynamometer and the WBB was acceptable. Thus, the WBB may be a valid instrument to assess hand grip strength in older adults.
Development of hybrid electric vehicle powertrain test system based on virtue instrument
NASA Astrophysics Data System (ADS)
Xu, Yanmin; Guo, Konghui; Chen, Liming
2017-05-01
Hybrid powertrain has become the standard configuration of some automobile models. The test system of hybrid vehicle powertrain was developed based on virtual instrument, using electric dynamometer to simulate the work of engines, to test the motor and control unit of the powertrain. The test conditions include starting, acceleration, and deceleration. The results show that the test system can simulate the working conditions of the hybrid electric vehicle powertrain under various conditions.
FY2011 Progress Report: Agreement 8697 - NOx Sensor Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woo, L Y; Glass, R S
Objectives are: (1) Develop an inexpensive, rapid-response, high-sensitivity and selective electrochemical sensor for oxides of nitrogen (NO{sub x}) for compression-ignition, direct-injection (CIDI) OBD II systems; (2) Explore and characterize novel, effective sensing methodologies based on impedance measurements and designs and manufacturing methods that are compatible with mass fabrication; and (3) Collaborate with industry in order to (ultimately) transfer the technology to a supplier for commercialization. Approach used is: (1) Use an ionic (O{sup 2-}) conducting ceramic as a solid electrolyte and metal or metal-oxide electrodes; (2) Correlate NO{sub x} concentration with changes in cell impedance; (3) Evaluate sensing mechanisms andmore » aging effects on long-term performance using electrochemical techniques; and (4) Collaborate with Ford Research Center to optimize sensor performance and perform dynamometer and on-vehicle testing. Work in FY2011 focused on using an algorithm developed in FY2010 in a simplified strategy to demonstrate how data from controlled laboratory evaluation could be applied to data from real-world engine testing. The performance of a Au wire prototype sensor was evaluated in the laboratory with controlled gas compositions and in dynamometer testing with diesel exhaust. The laboratory evaluation indicated a nonlinear dependence of the NO{sub x} and O{sub 2} sensitivity with concentration. For both NO{sub x} and O{sub 2}, the prototype sensor had higher sensitivity at concentrations less than {approx}20 ppm and {approx}7%, respectively, compared to lower NO{sub x} and O{sub 2} sensitivity at concentrations greater than {approx}50 ppm and {approx}10.5%, respectively. Results in dynamometer diesel exhaust generally agreed with the laboratory results. Diesel exhaust after-treatment systems will likely require detection levels less than {approx}20 ppm in order to meet emission regulations. The relevant mathematical expressions for sensitivity in different concentration regimes obtained from bench-level laboratory evaluation were used to adjust the sensor signal in dynamometer testing. Both NO{sub x} and O{sub 2} exhibited non-linear responses over the concentration regimes examined (0-100 ppm for NO{sub x} and 4-7% for O{sub 2}). Adjusted sensor signals had better agreement with both a commercial NO{sub x} sensor and FTIR measurements. However, the lack of complete agreement indicated that it was not possible to completely account for the nonlinear sensor behavior in certain concentration regimes. The agreement at lower NO{sub x} levels (less than 20 ppm) was better than at higher levels (50-100 ppm). Other progress in FY2011 included dynamometer testing of sensors with imbedded heaters and protective housings that were mounted directly into the exhaust manifold. Advanced testing protocols were used to evaluate the sensors. These experiments confirmed the potential for sensor robustness and durability. Advanced material processing methods appropriate for mass manufacturing, such as sputtering, are also being evaluated. A major milestone for this past year was the licensing of the LLNL NO{sub x} sensor technology to EmiSense Technologies, LLC. EmiSense has extensive experience and resources for the development of emission control sensors. A CRADA is in development that will allow LLNL to work in partnership with EmiSense to bring the LLNL NO{sub x} sensor technology to commercialization. Ford Motor Company is also a partner in this effort.« less
NASA Technical Reports Server (NTRS)
Shipps, P. R.
1980-01-01
A test and analysis program performed on four complete propulsion systems for an urban electric vehicle (EV) is described and results given. A dc series motor and a permanent magnet (PM) motor were tested, each powered by an EV battery pack and controlled by (1) a series/parallel voltage-switching (V-switch) system; and (2) a system using a pulse width modulation, 400 Hz transistorized chopper. Dynamometer tests were first performed, followed by eV performance predictions and data correlating road tests. During dynamometer tests using chopper control; current, voltage, and power were measured on both the battery and motor sides of the chopper, using three types of instrumentation. Conventional dc instruments provided adequate accuracy for eV power and energy measurements, when used on the battery side of the controller. When using the chopper controller, the addition of a small choke inductor improved system efficiency in the lower duty cycle range (some 8% increase at 50% duty cycle) with both types of motors. Overall system efficiency rankings during road tests were: (1) series motor with V-switch; (2) PM motor with V-switch; (3) series motor with chopper; and (4) PM motor with chopper. Chopper control of the eV was smoother and required less driver skill than V-switch control.
On-road particle number measurements using a portable emission measurement system (PEMS)
NASA Astrophysics Data System (ADS)
Gallus, Jens; Kirchner, Ulf; Vogt, Rainer; Börensen, Christoph; Benter, Thorsten
2016-01-01
In this study the on-road particle number (PN) performance of a Euro-5 direct-injection (DI) gasoline passenger car was investigated. PN emissions were measured using the prototype of a portable emission measurement system (PEMS). PN PEMS correlations with chassis dynamometer tests show a good agreement with a chassis dynamometer set-up down to emissions in the range of 1·1010 #/km. Parallel on-line soot measurements by a photo acoustic soot sensor (PASS) were applied as independent measurement technique and indicate a good on-road performance for the PN-PEMS. PN-to-soot ratios were 1.3·1012 #/mg, which was comparable for both test cell and on-road measurements. During on-road trips different driving styles as well as different road types were investigated. Comparisons to the world harmonized light-duty test cycle (WLTC) 5.3 and to European field operational test (euroFOT) data indicate the PEMS trips to be representative for normal driving. Driving situations in varying traffic seem to be a major contributor to a high test-to-test variability of PN emissions. However, there is a trend to increasing PN emissions with more severe driving styles. A cold start effect is clearly visible for PN, especially at low ambient temperatures down to 8 °C.
40 CFR 86.1327-96 - Engine dynamometer test procedures; overview.
Code of Federal Regulations, 2010 CFR
2010-07-01
... hydrocarbons, carbon monoxide, oxides of nitrogen, particulate, methanol and formaldehyde, as applicable. The... either in bags or continuously for hydrocarbons (HC), methane (CH4) carbon monoxide (CO), carbon dioxide... levels of hydrocarbon, carbon monoxide, carbon dioxide, and oxides of nitrogen and, if appropriate...
40 CFR 86.1327-96 - Engine dynamometer test procedures; overview.
Code of Federal Regulations, 2011 CFR
2011-07-01
... hydrocarbons, carbon monoxide, oxides of nitrogen, particulate, methanol and formaldehyde, as applicable. The... either in bags or continuously for hydrocarbons (HC), methane (CH4) carbon monoxide (CO), carbon dioxide... levels of hydrocarbon, carbon monoxide, carbon dioxide, and oxides of nitrogen and, if appropriate...
40 CFR 1066.240 - Torque transducer verification and calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.240 Torque transducer verification and calibration. Calibrate torque-measurement systems as described in 40 CFR 1065.310. ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Torque transducer verification and...
40 CFR 1066.240 - Torque transducer verification and calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.240 Torque transducer verification and calibration. Calibrate torque-measurement systems as described in 40 CFR 1065.310. ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Torque transducer verification and...
SAE 2018-01-1412 Constructing Engine Maps - Presentation at the April 2018 World Congress
This presentation describes important factors and approach, along with the process for constructing complete engine maps using engine dynamometer and in-vehicle test data for use in ALPHA or any other full vehicle simulation which performs similar analyses
40 CFR 86.159-00 - Exhaust emission test procedures for US06 emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and... analyzed for THC, CO, CO2, CH4, and NOX. (b) Dynamometer activities. (1) All official US06 tests shall be... pumps, the temperature recorder, the vehicle cooling fan, and the heated THC analysis recorder (diesel...
40 CFR 86.159-00 - Exhaust emission test procedures for US06 emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and... analyzed for THC, CO, CO2, CH4, and NOX. (b) Dynamometer activities. (1) All official US06 tests shall be... pumps, the temperature recorder, the vehicle cooling fan, and the heated THC analysis recorder (diesel...
40 CFR 86.159-00 - Exhaust emission test procedures for US06 emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and... analyzed for THC, CO, CO2, CH4, and NOX. (b) Dynamometer activities. (1) All official US06 tests shall be... pumps, the temperature recorder, the vehicle cooling fan, and the heated THC analysis recorder (diesel...
40 CFR 86.159-00 - Exhaust emission test procedures for US06 emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and... analyzed for THC, CO, CO2, CH4, and NOX. (b) Dynamometer activities. (1) All official US06 tests shall be... pumps, the temperature recorder, the vehicle cooling fan, and the heated THC analysis recorder (diesel...
NASA Technical Reports Server (NTRS)
Aghazadeh, Fred
2005-01-01
The objective of the planned summer research was to develop a procedure to determine the isokinetic functional strength of suited and unsuited participants in order to estimate the coefficient of micro-gravity suit on human strength. To accomplish this objective, the Anthropometry and Biomechanics Facility's Multipurpose, Multiaxial Isokinetic dynamometer (MMID) was used. Development of procedure involved selection and testing of seven routines to be tested on MMID. We conducted the related experiments and collected the data for 12 participants. In addition to the above objective, we developed a procedure to assess the fatiguing characteristics of suited and unsuited participants using EMG technique. We collected EMG data on 10 participants while performing a programmed routing on MMID. EMG data along with information on the exerted forces, effector speed, number of repetitions, and duration of each routine were recorded for further analysis. Finally, gathering and tabulation Of data for various human strengths for updating of MSIS (HSIS) strength requirement, which started in summer 2003, also continued.
Light-Duty Motor Vehicle Exhaust Particulate Matter Measurement in the Denver, Colorado, Area.
Cadle, Steven H; Mulawa, Patricia; Hunsanger, Eric C; Nelson, Ken; Ragazzi, Ronald A; Barrett, Richard; Gallagher, Gerald L; Lawson, Douglas R; Knapp, Kenneth T; Snow, Richard
1999-09-01
A study of particulate matter (PM) emissions from in-use, light-duty vehicles was conducted during the summer of 1996 and the winter of 1997 in the Denver, CO, region. Vehicles were tested as received on chassis dynamometers on the Federal Test Procedure Urban Dynamometer Driving Schedule (UDDS) and the IM240 driving schedule. Both PM10 and regulated emissions were measured for each phase of the UDDS. For the summer portion of the study, 92 gasoline vehicles, 10 diesel vehicles, and 9 gasoline vehicles with visible smoke emissions were tested once. For the winter, 56 gasoline vehicles, 12 diesel vehicles, and 15 gasoline vehicles with visible smoke were tested twice, once indoors at 60 °F and once outdoors at the prevailing temperature. Vehicle model year ranged from 1966 to 1996. Impactor particle size distributions were obtained on a subset of vehicles. Continuous estimates of the particle number emissions were obtained with an electrical aerosol analyzer. This data set is being provided to the Northern Front Range Air Quality Study program and to the State of Colorado and the U.S. Environmental Protection Agency for use in updating emissions inventories.
Barnhill, William C.; Gao, Hong; Kheireddin, Bassem; ...
2015-09-29
We have previously reported an oil-miscible phosphonium-organophosphate ionic liquid (IL) with an effective anti-wear (AW) functionality when added to a base oil by itself or combined with a conventional zinc dialkyldithiophosphate (ZDDP) for a synergistic effect. In this research, we investigated whether this synergy manifests in formulated engine oils. An experimental SAE 0W-16 engine oil was generated containing a combination of IL and ZDDP with equal phosphorus contribution. The prototype engine oil was first evaluated using tribological bench tests: AW performance in boundary lubrication (BL) and friction behavior (Stribeck curves) in elastohydrodynamic, mixed, and BL. In addition, the forthcoming standardmore » Sequence VIE engine dynamometer test was then conducted to demonstrate improved fuel economy. Results were benchmarked against those of another experimental engine oil with almost the same formulation except using ZDDP only without the IL (similar total phosphorus content). The IL-ZDDP formulation consistently outperforms the ZDDP-only formulation in friction reduction and wear protection, and results from the bench and engine tests are well correlated.« less
Astronaut candidate strength measurement using the Cybex 2 and the LIDO Multi-Joint 2 dynamometers
NASA Technical Reports Server (NTRS)
Carroll, Amy E.; Wilmington, Robert P.
1992-01-01
The Anthropometry and Biomechanics Laboratory in the man-Systems division at NASA's Johnson Space Center has as one of its responsibilities the anthropometry and strength measurement data collection of astronaut candidates. The anthropometry data is used to ensure that the astronaut candidates are within the height restrictions for space vehicle and space suit design requirements, for example. The strength data is used to help detect abnormalities or isolate injuries to muscle groups that could jeopardize the astronauts safety. The Cybex II Dynamometer has been used for strength measurements from 1985 through 1991. The Cybex II was one of the first instruments of its kind to measure strength and similarity of muscle groups by isolating the specific joint of interest. In November 1991, a LIDO Multi-Joint II Dynamometer was purchased to upgrade the strength measurement data collection capability of the Anthropometry and Biomechanics Laboratory. The LIDO Multi-Joint II Dynamometer design offers several advantages over the Cybex II Dynamometer including a more sophisticated method of joint isolation and a more accurate and efficient computer based data collection system.
A microcomputer controlled snow ski binding system--I. Instrumentation and field evaluation.
MacGregor, D; Hull, M L; Dorius, L K
1985-01-01
This paper presents the design and field evaluation of the first microcomputer controlled ski binding system. This system incorporates an Intel 8086 microcomputer controller and an integral binding/dynamometer. This instrumentation system not only undertakes real time control, but also it records dynamometer data via a miniature digital cassette tape recorder. The integral binding/dynamometer offers the same operational and mounting convenience of commercially available mechanical bindings. The binding may be released either manually or electrically via the controller. Comprised of four octagonal half strain rings, the strain gage dynamometer measures the three moment load components at the boot. To enable the user to conveniently operate the computer, extensive operating software was developed. The operating software is discussed in relation to both the acquisition and storage of data from the dynamometer and the control of the electro-mechanical snow ski binding. The binding system has been used successfully to both record boot moment components and control ski binding release during actual skiing maneuvers. Moment histories typical of three common recreational skiing maneuvers are presented.
Toumi, A; Leteneur, S; Gillet, C; Debril, J-F; Decoufour, N; Barbier, F; Jakobi, J M; Simoneau-Buessinger, Emilie
2015-11-01
Many studies have focused on maximum torque exerted by ankle joint muscles during plantar flexion. While strength parameters are typically measured with isokinetic or isolated ankle dynamometers, these devices often present substantial limitations for the measurement of torque because they account for force in only 1 dimension (1D), and the device often constrains the body in a position that augments torque through counter movements. The purposes of this study were to determine the contribution of body position to ankle plantar-flexion torque and to assess the use of 1D and 3D torque sensors. A custom designed 'Booted, Open-Unit, Three dimension, Transportable, Ergometer' (B.O.T.T.E.) was used to quantify plantar flexion in two conditions: (1) when the participant was restrained within the unit (locked-unit) and (2) when the participant's position was independent of the ankle dynamometer (open-unit). Ten young males performed maximal voluntary isometric plantar-flexion contractions using the B.O.T.T.E. in open and locked-unit mechanical configurations. The B.O.T.T.E. was reliable with ICC higher than 0.90, and CV lower than 7 %. The plantar-flexion maximal resultant torque was significantly higher in the locked-unit compared with open-unit configuration (P < 0.001; +61 to +157 %) due to the addition of forces from the body being constrained within the testing device. A 1D compared with 3D torque sensor significantly underestimated the proper capacity of plantar-flexion torque production (P < 0.001; -37 to -60 %). Assessment of plantar-flexion torque should be performed with an open-unit dynamometer mounted with a 3D sensor that is exclusive of accessory muscles but inclusive of all ankle joint movements.
Fearon, Angela; Neeman, Teresa; Smith, Paul; Scarvell, Jennie; Cook, Jill
2017-02-01
What are the functional differences between people with greater trochanteric pain syndrome (GT), hip osteoarthritis (OA) or an asymptomatic population as measured by walking, Time Up and Go, single leg standing and strength? Cross sectional study with blinded measurers. 38 participants with GT, 20 with end stage hip OA and 21 asymptomatic healthy control (AS) participants. All participants were women. Pain (numeric rating scale), Walking speed (m/s), cadence (steps/min) and step length (m) measured via the 10m walk test and the Timed Up and Go; balance via single leg stance (s) duration; and hip abduction, adduction, medial and lateral rotation strength, standardized to body mass (BM) via the body mass average index (BMavg), measured via a wall mounted dynamometer. The two symptomatic groups reported similar pain levels (p=0.226), more pain then the AS group (p<0.000). Compared to the AS participants, participants with GT or hip OA demonstrated lower walking speed (10mwt and TUG, p<0.001), lower cadence and shorter duration single leg stance on the affected leg (p<0.05). Participants with GT or hip OA also demonstrated bilaterally weaker hip abduction than the AS group (p≤0.005). Compared to AS and GT participants, participants with hip OA demonstrated adduction weakness on the affected side (p=0.008 and p=0.002 respectively). There is a significant level of dysfunction and impairments associated with GT and hip OA. As activity limitations do not appear to be differentiated by structural impairments, we suggest that pain, rather than the underlying pathology may be the driving impairment that leads to walking and single leg standing dysfunction. Copyright © 2016 Elsevier B.V. All rights reserved.
DOT National Transportation Integrated Search
1976-11-01
Experimental data were obtained in dynamometer tests of the 1975 Ford 140 cubic-inch displacement, 2-bbl engine to determine steady-state fuel consumption and emissions of hydrocarbon, carbon monoxide, and oxides of nitrogen. These data were obtained...
DOT National Transportation Integrated Search
1976-11-01
Experimental data were obtained in dynamometer tests of the 1975 Datsun, 119 cubic-inch displacement, 2-bbl engine to determine steady-state fuel consumption and emissions of hydrocarbon, carbon monoxide, and oxides of nitrogen. These data were obtai...
40 CFR 86.537-90 - Dynamometer test runs.
Code of Federal Regulations, 2014 CFR
2014-07-01
... “transient” formaldehyde exhaust sample, the “transient” dilution air sample bag, the “transient” methanol... start “transient” exhaust and dilution air bag samples to the analytical system and process the samples... Section 86.537-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...
40 CFR 86.537-90 - Dynamometer test runs.
Code of Federal Regulations, 2012 CFR
2012-07-01
... “transient” formaldehyde exhaust sample, the “transient” dilution air sample bag, the “transient” methanol... start “transient” exhaust and dilution air bag samples to the analytical system and process the samples... Section 86.537-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...
40 CFR 86.537-90 - Dynamometer test runs.
Code of Federal Regulations, 2013 CFR
2013-07-01
... “transient” formaldehyde exhaust sample, the “transient” dilution air sample bag, the “transient” methanol... start “transient” exhaust and dilution air bag samples to the analytical system and process the samples... Section 86.537-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...
Lustosa, Lygia Paccini; Batista, Patrícia Parreira; Pereira, Daniele Sirineu; Pereira, Leani Souza Máximo; Scianni, Aline; Ribeiro-Samora, Giane Amorim
2017-01-01
Sarcopenia is a multifactorial geriatric syndrome with complex interrelationships. Increased plasma levels of inflammatory mediators increase the catabolic stimuli of the musculature, thereby causing a decrease in mass and muscular function. The objective of this study was to compare the performance of the knee extensors test (by isokinetic dynamometer) and plasma levels of interleukin-6 (IL-6) and soluble receptors of tumor necrosis factor alpha (sTNFR1) between sarcopenics and non-sarcopenics community-dwelling elderly women residents of Brazil. The diagnosis of sarcopenia included measurements of body composition (by densitometry with dual energy source of X-ray), handgrip strength (by Jamar ® dynamometer), and the usual gait velocity according to the recommendations of the European Working Group on Sarcopenia in Older People. In both sarcopenics and non-sarcopenics elderly women, we evaluated the muscle function by knee extensors test (using an isokinetic dynamometer Byodex System 4 Pro ® ) at angular speeds of 60°/s and 180°/s) and also we evaluated the plasma concentrations of IL-6 and sTNFR1. Comparisons of muscle performance between groups were carried out using mixed factorial ANOVA with post hoc Bonferroni test; sTNFR1 and IL-6 variables were analyzed by applying Mann-Whitney U test. Statistical differences were observed between groups regarding muscle power ( P =0.01), total work adjusted to body weight ( P =0.01) at a rate of 180°/s, and plasma levels of sTNFR1 ( P =0.01). Sarcopenic elder women showed lower performance of the lower limbs, especially at a higher speed, predisposing these older women to greater vulnerability in functional activities that require agility and postural stability. Plasma levels of sTNFR1 were higher for non-sarcopenics elderlies. However, due to the observational nature of the study, it was impossible to infer causality among the variables surveyed.
NASA Technical Reports Server (NTRS)
Hewitt, R.; Bryant, J.
1982-01-01
Three full size developmental batteries were tested with electric vehicles; two nickel-iron batteries and a lead-acid battery. Constant speed and driving schedule tests were done on a chassis dynamometer. Several aspects of battery performance were evaluated for capacity, recharge efficiency, voltage response, and self discharge. Each of these three batteries exhibited some strengths and some weaknesses.
Jensen, K K; Kjaer, M; Jorgensen, L N
2016-12-01
To determine the reliability of measurements obtained by the Good Strength dynamometer, determining isometric abdominal wall and back muscle strength in patients with ventral incisional hernia (VIH) and healthy volunteers with an intact abdominal wall. Ten patients with VIH and ten healthy volunteers with an intact abdominal wall were each examined twice with a 1 week interval. Examination included the assessment of truncal flexion and extension as measured with the Good Strength dynamometer, the completion of the International Physical Activity Questionnaire (IPAQ) and the self-assessment of truncal strength on a visual analogue scale (SATS). The test-retest reliability of truncal flexion and extension was assessed by interclass correlation coefficient (ICC), and Bland and Altman graphs. Finally, correlations between truncal strength, and IPAQ and SATS were examined. Truncal flexion and extension showed excellent test-retest reliability for both patients with VIH (ICC 0.91 and 0.99) and healthy controls (ICC 0.97 and 0.96). Bland and Altman plots showed that no systematic bias was present for neither truncal flexion nor extension when assessing reliability. For patients with VIH, no significant correlations between objective measures of truncal strength and IPAQ or SATS were found. For healthy controls, both truncal flexion (τ 0.58, p = 0.025) and extension (τ 0.58, p = 0.025) correlated significantly with SATS, while no other significant correlation between truncal strength measures and IPAQ was found. The Good Strength dynamometer provided a reliable, low-cost measure of truncal flexion and extension in patients with VIH.
1981-01-01
chamber, with a 0-60,000 RPM, 300 HP dynamometer, was selected as the test facility. A rotary transformer ( brushless ) torque sensor, using air /oil... brushless ) of 100 and 500 in-lb torque ranges were selected from Lebow Associates, Inc. of Troy, Michigan. Special air / oil mist lubrication for the...period August 1979 - October 1980 I Approved for public release; distribution unlimited. _ DTIC AERO PROPULSION LABORATORY AIR FORCE WRIGHT AERONAUTICAL
UPS Hydraulic Hybrid Delivery Van Testing | Transportation Research | NREL
, use, fuel economy, reliability, and other vehicle performance data. The in-lab portion involves dynamometer evaluation at NREL's Renewable Fuels and Lubricants Laboratory to determine the fuel economy and Hydraulic Hybrid and Conventional Parcel Delivery Vehicles' Measured Laboratory Fuel Economy on Targeted
40 CFR 86.1327-96 - Engine dynamometer test procedures; overview.
Code of Federal Regulations, 2012 CFR
2012-07-01
... either in bags or continuously for hydrocarbons (HC), methane (CH4) carbon monoxide (CO), carbon dioxide..., methane and/or methanol and/or formaldehyde. In addition, for diesel-cycle engines, particulates are... if typical of the in-use application. (5) The engine may be equipped with a production-type starter...
40 CFR 86.1327-96 - Engine dynamometer test procedures; overview.
Code of Federal Regulations, 2013 CFR
2013-07-01
... either in bags or continuously for hydrocarbons (HC), methane (CH4) carbon monoxide (CO), carbon dioxide..., methane and/or methanol and/or formaldehyde. In addition, for diesel-cycle engines, particulates are... if typical of the in-use application. (5) The engine may be equipped with a production-type starter...
40 CFR 86.1332-90 - Engine mapping procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... § 86.1332-90 Engine mapping procedures. (a) Mount test engine on the engine dynamometer. (b) Determine... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Engine mapping procedures. 86.1332-90... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission...
40 CFR 86.1332-90 - Engine mapping procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... § 86.1332-90 Engine mapping procedures. (a) Mount test engine on the engine dynamometer. (b) Determine... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Engine mapping procedures. 86.1332-90... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission...
40 CFR 86.1332-90 - Engine mapping procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... § 86.1332-90 Engine mapping procedures. (a) Mount test engine on the engine dynamometer. (b) Determine... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Engine mapping procedures. 86.1332-90... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission...
DOT National Transportation Integrated Search
1977-01-01
Experimental data were obtained in dynamometer tests of the Mercedes Benz Model OM617 diesel engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitroge, and smoke) at steady-state engine-operating modes. The o...
DOT National Transportation Integrated Search
1977-08-01
Experimental data were obtained in dynamometer tests of the Mitsubishi Model 6DS7 diesel engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen, and smoke) at steady-state engine operating modes. The obje...
40 CFR 86.237-08 - Dynamometer test run, gaseous emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... temperature recorder, the vehicle cooling fan, and the heated THC analysis recorder (diesel-cycle only). (The heat exchanger of the constant volume sampler, if used, petroleum-fueled diesel-cycle THC analyzer continuous sample line and filter, methanol-fueled vehicle THC, methanol and formaldehyde sample lines, if...
40 CFR 86.237-08 - Dynamometer test run, gaseous emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... temperature recorder, the vehicle cooling fan, and the heated THC analysis recorder (diesel-cycle only). (The heat exchanger of the constant volume sampler, if used, petroleum-fueled diesel-cycle THC analyzer continuous sample line and filter, methanol-fueled vehicle THC, methanol and formaldehyde sample lines, if...
Fluidic Sensor Temperature Indicating System.
A fluidic sensor temperature indicating system designed by Honeywell Inc was tested on a T56 engine during dynamometer calibration. It was also...based on the sensor being mounted in a T56 engine showed a hot gas temperature drop from 1970F at the sensor entrance to 1760F in the sensor pulsation
DOT National Transportation Integrated Search
1977-08-01
Experimental data were obtained in dynamometer tests of a 1975 Chevrolet 250-CID, 1-bbl engine to determine fuel consumption and emissions (hydrocarbons, carbon monoxide, and oxides of nitrogen) at steady-state engine operating modes. The objective o...
DOT National Transportation Integrated Search
1977-08-01
Experimental data were obtained in dynamometer tests of a 1975 Chrysler 225-CID, 1-bbl engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, and oxides of nitrogen) at steady-state engine operating modes. The objective of ...
DOT National Transportation Integrated Search
1976-09-01
Experimental data were obtained in dynamometer tests of the 1975 Chevrolet, 350 cubic-inch displacement, 2-bbl engine, to determine the steady-state fuel consumption and emissions of hydrocarbons, carbon monoxide and oxides of nitrogen. These data we...
MERCURY EMISSIONS FROM GASOLINE AND DIESEL POWERED ON-ROAD VEHICLES
Measurements of elemental gaseous mercury (Hg0), divalent reactive gaseous mercury (RGM), and particulate phase mercury (Hg(p)) were made from 14 gasoline and 2 diesel powered in-use light-duty vehicles on a chassis dynamometer. All vehicles were tested under both cold and hot st...
DOT National Transportation Integrated Search
1981-02-01
Experimental data were obtained in dynamometer tests of a 1978 Buick 231 CID turbocharged to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine operating modes. The objective of the prog...
DOT National Transportation Integrated Search
1981-06-01
Experimental data were obtained in dynamometer tests of a 1977 Chrysler 318 CID engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine operating modes. The objective of the program...
DOT National Transportation Integrated Search
1979-02-01
Experimental data were obtained in dynamometer tests of a 1978 Honda 98 CID engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine operating modes. The objective of the program is ...
DOT National Transportation Integrated Search
1978-05-01
Experimental data were obtained in dynamometer tests of a 1976 Chevrolet 85 CID engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective of the program...
DOT National Transportation Integrated Search
1978-05-01
Experimental data were obtained in dynamometer tests of a 1975 Chevrolet 350 CID engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective of the progra...
DOT National Transportation Integrated Search
1977-08-01
Experimental data were obtained in dynamometer tests of a 1975 Chrysler 318-CID, 2-bbl engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, and oxides of nitrogen) at steady-state engine operating modes. The objective of ...
40 CFR 86.235-94 - Dynamometer procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., carbon dioxide, and oxides of nitrogen. (b) As long as an emission sample is not taken, practice runs...) Four-wheel drive vehicles will be tested in a two-wheel drive mode of operation. Full-time four-wheel drive vehicles will have one set of drive wheels temporarily disengaged by the vehicle manufacturer...
Performance characteristics of an electric vehicle lead-acid battery pack at elevated temperatures
NASA Technical Reports Server (NTRS)
Chapman, P.
1982-01-01
Discharge testing data electric car battery pack over initial electrolyte temperature variations between 27 and 55 C are presented. The tests were conducted under laboratory conditions and then compared to detailed electric vehicle simulation models. Battery discharge capacity increased with temperature for constant current discharges, and battery energy capacity increased with temperature for constant power discharges. Dynamometer tests of the electric test vehicle showed an increase in range of 25% for the higher electrolyte temperature.
Hwa, Mei-Yin; Yu, Tai-Yi
2014-07-01
This investigation adopts vehicle tracking manner to establish real-world driving patterns and estimates emission factors with dynamometers with 23 traffic-driving variables for 384 in-use light-duty passenger vehicles during non-rush hour. Adequate numbers of driving variables were decided with factor analysis and cluster analysis. The dynamometer tests were performed on FTP75 cycle and five local driving cycles derived from real-world speed profiles. Results presented that local driving cycles and FTP75 cycle were completely different in driving characteristic parameters of typical driving cycles and emission factors. The highest values of emission factor ratios of local driving cycle and FTP75 cycle for CO, NMHC, NO x , CH4, and CO2 were 1.38, 1.65, 1.58, 1.39, and 1.14, respectively.
Aramaki, Hidefumi; Katoh, Munenori; Hiiragi, Yukinobu; Kawasaki, Tsubasa; Kurihara, Tomohisa; Ohmi, Yorikatsu
2016-07-01
[Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subjects' right legs was measured under two posture positions using two devices: a handheld dynamometer with a belt and an isokinetic dynamometer. Reliability was evaluated using an intra-class correlation coefficient (ICC); relatedness and validity were evaluated using Pearson's product moment correlation coefficient. Differences in measurements of devices were assessed by two-way ANOVA. [Results] ICC (1, 1) was ≥0.9; significant positive correlations in measurements were found between the two devices under both conditions. No main effect was found between the measurement values. [Conclusion] Our findings revealed that there was relatedness, reliability, and validity of this method for isometric muscle strength measurements using a handheld dynamometer with a belt.
Validity of trunk extensor and flexor torque measurements using isokinetic dynamometry.
Guilhem, Gaël; Giroux, Caroline; Couturier, Antoine; Maffiuletti, Nicola A
2014-12-01
This study aimed to evaluate the validity and test-retest reliability of trunk muscle strength testing performed with a latest-generation isokinetic dynamometer. Eccentric, isometric, and concentric peak torque of the trunk flexor and extensor muscles was measured in 15 healthy subjects. Muscle cross sectional area (CSA) and surface electromyographic (EMG) activity were respectively correlated to peak torque and submaximal isometric torque for erector spinae and rectus abdominis muscles. Reliability of peak torque measurements was determined during test and retest sessions. Significant correlations were consistently observed between muscle CSA and peak torque for all contraction types (r=0.74-0.85; P<0.001) and between EMG activity and submaximal isometric torque (r ⩾ 0.99; P<0.05), for both extensor and flexor muscles. Intraclass correlation coefficients were comprised between 0.87 and 0.95, and standard errors of measurement were lower than 9% for all contraction modes. The mean difference in peak torque between test and retest ranged from -3.7% to 3.7% with no significant mean directional bias. Overall, our findings establish the validity of torque measurements using the tested trunk module. Also considering the excellent test-retest reliability of peak torque measurements, we conclude that this latest-generation isokinetic dynamometer could be used with confidence to evaluate trunk muscle function for clinical or athletic purposes. Copyright © 2014 Elsevier Ltd. All rights reserved.
Investigations and Tests in the Towing Basin at Guidonia
NASA Technical Reports Server (NTRS)
Cremona, C
1939-01-01
The experimental methods at the Guidonia towing basin are discussed including specifications. Some of the components examined are the bridge towing carriage, side towing carriage, catapult installation, and dynamometer systems. Tests were performed on hulls and floats, as well as motor boats and torpedo shaped bodies. Theoretical investigations were also performed to determine pressure distributions on geometrically simple bodies, propagation of small wave motions, and planing and submerged surfaces.
Development of an integrated digital hand grip dynamometer and norm of hand grip strength.
Chang, Ho; Chen, Chih-Hao; Huang, Tung-Sun; Tai, Chun-Yen
2015-01-01
This study designs and fabricates a novel integrated digital hand grip dynamometer and analyzes collected grip strength data. The dynamometer directly stores collected data in a computer, unlike those on the market that cannot directly store information. A strain gauge load cell is used as a force sensor. The dynamometer is designed to maximize ergonomics. Excitation voltage of the load cell is 5 V, and a 9 V battery supplies power to its circuit. The signal receiver is National Instruments (NI) data acquisition (DAQ) card that transmits signals to the computer. The operation system is designed using LabView. This study assesses the correlation between variables of collected data. The correlation coefficients for height, weight and palm length were 0.793, 0.609 and 0.715, respectively, indicating that variables were moderately to strongly correlate with grip strength.
On the road performance tests of electric test vehicle for correlation with road load simulator
NASA Technical Reports Server (NTRS)
Dustin, M. O.; Slavik, R. J.
1982-01-01
A dynamometer (road load simulator) is used to test and evaluate electric vehicle propulsion systems. To improve correlation between system tests on the road load simulator and on the road, similar performance tests are conducted using the same vehicle. The results of track tests on the electric propulsion system test vehicle are described. The tests include range at constant speeds and over SAE J227a driving cycles, maximum accelerations, maximum gradability, and tire rolling resistance determination. Road power requirements and energy consumption were also determined from coast down tests.
Mobile propeller dynamometer validation
NASA Astrophysics Data System (ADS)
Morris, Mason Wade
With growing interest in UAVs and OSU's interest in propeller performance and manufacturing, evaluating UAV propeller and propulsion system performance has become essential. In attempts to evaluate these propellers a mobile propeller dynamometer has been designed, built, and tested. The mobile dyno has been designed to be cost effective through the ability to load it into the back of a test vehicle to create simulated forward flight characteristics. This allows much larger propellers to be dynamically tested without the use of large and expensive wind tunnels. While evaluating the accuracy of the dyno, several improvements had to be made to get accurate results. The decisions made to design and improve the mobile propeller dyno will be discussed along with attempts to validate the dyno by comparing its results against known sources. Another large part of assuring the accuracy of the mobile dyno is determining if the test vehicle will influence the flow going into the propellers being tested. The flow into the propeller needs to be as smooth and uniform as possible. This is determined by characterizing the boundary layer and accelerated flow over the vehicle. This evaluation was accomplished with extensive vehicle aerodynamic measurements with the use of full-scale tests using a pitot-rake and the actual test vehicle. Additional tests were conducted in Oklahoma State University's low speed wind tunnel with a 1/8-scale model using qualitative flow visualization with smoke. Continuing research on the mobile dyno will be discussed, along with other potential uses for the dyno.
DOT National Transportation Integrated Search
1978-04-01
Experimental data were obtained in dynamometer tests of a 1975 Perkins 247-CID diesel engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective of the p...
DOT National Transportation Integrated Search
1979-02-01
Experimental data were obtained in dynamometer tests of a 1978 Oldsmobile Diesel, 350 CID (5.7 Liters) engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The o...
DOT National Transportation Integrated Search
1978-05-01
Experimental data were obtained in dynamometer tests of a 1975 Mazda 70 CID, 4V rotary engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective of the ...
NREL Bridges Fuels and Engines R&D to Maximize Vehicle Efficiency and
innovation-from fuel chemistry, conversion, and combustion to the evaluation of advanced fuels in actual -cylinder engine for advanced compression ignition fuels research will be installed and commissioned in the vehicle performance and emissions research, two engine dynamometer test cells for advanced fuels research
DOT National Transportation Integrated Search
1979-02-01
Experimental data were obtained in dynamometer tests of a 1978 VW 90 CID engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine operating modes. The objective of the program is to ...
DOT National Transportation Integrated Search
1979-02-01
Experimental data were obtained in dynamometer tests of a 1977 Chrysler 318 CID engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine operating modes. The objective of the program...
40 CFR 86.137-94 - Dynamometer test run, gaseous and particulate emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., if applicable), the temperature recorder, the vehicle cooling fan, and the heated THC analysis... diesel-cycle THC analyzer continuous sample line and filter, methanol-fueled vehicle THC, methanol and... measuring devices to zero. (i) For gaseous bag samples (except THC samples), the minimum flow rate is 0.17...
40 CFR 86.137-94 - Dynamometer test run, gaseous and particulate emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., if applicable), the temperature recorder, the vehicle cooling fan, and the heated THC analysis... diesel-cycle THC analyzer continuous sample line and filter, methanol-fueled vehicle THC, methanol and... measuring devices to zero. (i) For gaseous bag samples (except THC samples), the minimum flow rate is 0.17...
40 CFR 86.1333-90 - Transient test cycle generation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... zero percent speed specified in the engine dynamometer schedules (appendix I (f)(1), (f)(2), or (f)(3... feedback torque equal to zero (using, for example, clutch disengagement, speed to torque control switching... reference speed and reference torque are zero percent values. For each idle segment that is ten seconds or...
40 CFR 86.1333-90 - Transient test cycle generation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... zero percent speed specified in the engine dynamometer schedules (appendix I (f)(1), (f)(2), or (f)(3... feedback torque equal to zero (using, for example, clutch disengagement, speed to torque control switching... reference speed and reference torque are zero percent values. For each idle segment that is ten seconds or...
Speciated volatile organic compounds (VOCs) were measured in diesel exhaust from three medium heavy-duty trucks equipped with modern aftertreatment technologies. Emissions testing was conducted on a chassis dynamometer at two ambient temperatures (-6.7°C and 21.7°C) operating on ...
DOT National Transportation Integrated Search
1978-04-01
Experimental data were obtained in dynamometer tests of a 1975 AMC 258-CID production 1V engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective of th...
DOT National Transportation Integrated Search
1979-02-01
Experimental data were obtained in dynamometer tests of a 1978 Pontiac 301 CID engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine operating modes. The objective of the program ...
DOT National Transportation Integrated Search
1978-05-01
Experimental data were obtained in dynamometer tests of a 1975 Buick 455 CID, 4V engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective of the progra...
DOT National Transportation Integrated Search
1978-04-01
Experimental data were obtained in dynamometer tests of a 1976 Chevrolet 305-CID V-8 engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective of the pr...
DOT National Transportation Integrated Search
1980-09-01
Experimental data were obtained in dynamometer tests of a 1978 Ford 140 CID engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine operating modes. The objective of the program is ...
DOT National Transportation Integrated Search
1978-05-01
Experimental data were obtained in dynamometer tests of a 1975 Volvo, 2.0 liter (121 CID) engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective of t...
DOT National Transportation Integrated Search
1978-05-01
Experimental data were obtained in dynamometer tests of a 1977 Ford 2.3 liter (140 CID) engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective of the...
DOT National Transportation Integrated Search
1978-05-01
Experimental data were obtained in dynamometer tests of a 1977 Volvo 130 CID engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective of the program is...
DOT National Transportation Integrated Search
1978-05-01
Experimental data were obtained in dynamometer tests of a 1977 Ford 171 CID engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective of the program is ...
DOT National Transportation Integrated Search
1978-05-01
Experimental data were obtained in dynamometer tests of a 1975 Dodge Colt 1.6 liter (98 CID) engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective o...
DOT National Transportation Integrated Search
1978-04-01
Experimental data were obtained in dynamometer tests of a 1977 Chrysler 225-CID engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective of the program...
DOT National Transportation Integrated Search
1979-02-01
Experimental data were obtained in dynamometer tests of a 1978 Ford 140 300 CID engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine operating modes. The objective of the program...
DOT National Transportation Integrated Search
1978-05-01
Experimental data were obtained in dynamometer tests of a 1976 Ford 400 CID, 2V engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective of the program...
DOT National Transportation Integrated Search
1978-05-01
Experimental data were obtained in dynamometer tests of a 1975 Ford 351 CID, 2V, Windsor engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective of th...
DOT National Transportation Integrated Search
1979-02-01
Experimental data were obtained in dynamometer tests of a 1978 Chevrolet 200 CID engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine operating modes. The objective of the progra...
DOT National Transportation Integrated Search
1979-02-01
Experimental data were obtained in dynamometer tests of a 1978 Buick 231 CID turbocharged to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine operating modes. The objective of the prog...
DOT National Transportation Integrated Search
1979-02-01
Experimental data were obtained in dynamometer tests of a 1978 Pontiac 151 CID engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine operating modes. The objective of the program ...
DOT National Transportation Integrated Search
1979-02-01
Experimental data were obtained in dynamometer tests of a 1978 AMC 121 CID engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine operating modes. The objective of the program is t...
DOT National Transportation Integrated Search
1978-05-01
Experimental data were obtained in dynamometer tests of a 1976 Nissan diesel engine, Model SD-33 CN6-33, to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The object...
40 CFR 1065.110 - Work inputs and outputs, accessory work, and operator demand.
Code of Federal Regulations, 2013 CFR
2013-07-01
...-current and water-brake dynamometers for any testing that does not involve engine motoring, which is... resistor load bank to simulate electrical loads. (3) Pump, compressor, and turbine work. Use pumps, compressors, and turbines that are of the type and capacity installed in use. Use working fluids that are of...
40 CFR 1065.110 - Work inputs and outputs, accessory work, and operator demand.
Code of Federal Regulations, 2014 CFR
2014-07-01
...-current and water-brake dynamometers for any testing that does not involve engine motoring, which is... resistor load bank to simulate electrical loads. (3) Pump, compressor, and turbine work. Use pumps, compressors, and turbines that are of the type and capacity installed in use. Use working fluids that are of...
40 CFR 1065.110 - Work inputs and outputs, accessory work, and operator demand.
Code of Federal Regulations, 2012 CFR
2012-07-01
...-current and water-brake dynamometers for any testing that does not involve engine motoring, which is... resistor load bank to simulate electrical loads. (3) Pump, compressor, and turbine work. Use pumps, compressors, and turbines that are of the type and capacity installed in use. Use working fluids that are of...
40 CFR 1065.110 - Work inputs and outputs, accessory work, and operator demand.
Code of Federal Regulations, 2011 CFR
2011-07-01
...-current and water-brake dynamometers for any testing that does not involve engine motoring, which is... resistor load bank to simulate electrical loads. (3) Pump, compressor, and turbine work. Use pumps, compressors, and turbines that are of the type and capacity installed in use. Use working fluids that are of...
40 CFR 1065.110 - Work inputs and outputs, accessory work, and operator demand.
Code of Federal Regulations, 2010 CFR
2010-07-01
...-current and water-brake dynamometers for any testing that does not involve engine motoring, which is... resistor load bank to simulate electrical loads. (3) Pump, compressor, and turbine work. Use pumps, compressors, and turbines that are of the type and capacity installed in use. Use working fluids that are of...
40 CFR 86.1333-90 - Transient test cycle generation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... zero percent speed specified in the engine dynamometer schedules (appendix I (f)(1), (f)(2), or (f)(3... feedback torque equal to zero (using, for example, clutch disengagement, speed to torque control switching... reference speed and reference torque are zero percent values. For each idle segment that is ten seconds or...
NASA Astrophysics Data System (ADS)
Huang, Cheng; Tao, Shikang; Lou, Shengrong; Hu, Qingyao; Wang, Hongli; Wang, Qian; Li, Li; Wang, Hongyu; Liu, Jian'gang; Quan, Yifeng; Zhou, Lanlan
2017-11-01
CO, THC, NOx, and PM emission factors of 51 light-duty gasoline vehicles (LDGVs) spanning the emission standards from Euro 2 to Euro 5 were measured by a chassis dynamometer. High frequencies of high-emitting vehicles were observed in Euro 2 and Euro 3 LDGV fleet. 56% and 33% of high-emitting vehicles contributed 81%-92% and 82%-85% of the emissions in Euro 2 and Euro 3 test fleet, respectively. Malfunctions of catalytic convertors after high strength use are the main cause of the high emissions. Continuous monitoring of a gasoline vehicle dominated tunnel in Shanghai, China was conducted to evaluate the average emission factors of vehicles in real-world. The results indicated that the emission factors of LDGVs were considerably underestimated in EI guidebook in China. The overlook of high-emitting vehicles in older vehicle fleet is the main reason for this underestimation. Enhancing the supervision of high emission vehicles and strengthening the compliance tests of in-use vehicles are essential measures to control the emissions of in-use gasoline vehicles at the present stage in China.
SPECIATED VOC EMISSIONS FROM MODERN GDI LIGHT ...
Chassis dynamometer emissions testing was conducted to characterize speciated volatile organic compounds (VOCs), including mobile source air toxics (MSATs) and ozone precursors, in exhaust emissions from three modern gasoline direct injection (GDI) light-duty vehicles. Each GDI vehicle tested in this study utilized slightly different fuel injection technology: Vehicle 1 used a 2.4 liter, naturally aspirated, wall-guided GDI; Vehicle 2 used a 1.8 liter, turbocharged GDI engine; Vehicle 3 used a 1.5 liter, turbocharged, spray-guided GDI engine. Vehicle testing was conducted in a temperature controlled chassis dynamometer test cell at 22 °C over the EPA Federal Test Procedure (FTP) and a portion of the Supplemental FTP (SFTP). The FTP was conducted as a three phase cycle with a cold start, hot transient, and warm start phase (also known as the FTP-75 driving cycle). The SFTP consisted of the US06 driving cycle (conducted without the vehicle’s air conditioning on), which provides a more aggressive driving pattern than the FTP. The vehicles operated on 10 percent ethanol blended gasoline (E10). VOC emissions from diluted vehicle exhaust were sampled over each FTP phase and over the Supplemental FTP with SUMMA canisters for EPA Method TO-15 analysis and with DNPH cartridges for carbonyl analysis by EPA Method TO-11A. This presentation will report the impact of driving cycle and GDI technology on speciated MSAT emissions. MSAT emission rates will be compared
40 CFR 1066.210 - Dynamometers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... chassis dynamometer typically uses electrically generated load forces combined with its rotational inertia... (known as “road load”). Load forces are calculated using vehicle-specific coefficients and response characteristics. The load forces are applied to the vehicle tires by rolls connected to intermediate motor...
40 CFR 1066.210 - Dynamometers.
Code of Federal Regulations, 2013 CFR
2013-07-01
... chassis dynamometer typically uses electrically generated load forces combined with its rotational inertia... (known as “road load”). Load forces are calculated using vehicle-specific coefficients and response characteristics. The load forces are applied to the vehicle tires by rolls connected to intermediate motor...
NASA Astrophysics Data System (ADS)
Merkisz, Jerzy; Fuc, Pawel; Lijewski, Piotr; Ziolkowski, Andrzej; Galant, Marta; Siedlecki, Maciej
2016-08-01
We have analyzed the increase of the overall efficiency of a spark ignition engine through energy recovery following the application of an automotive thermoelectric generator (ATEG) of our own design. The design of the generator was developed following emission investigations during vehicle driving under city traffic conditions. The measurement points were defined by actual operation conditions (engine speed and load), subsequently reproduced on an engine dynamometer. Both the vehicle used in the on-road tests and the engine dynamometer were fit with the same, downsized spark ignition engine (with high effective power-to-displacement ratio). The thermodynamic parameters of the exhaust gases (temperature and exhaust gas mass flow) were measured on the engine testbed, along with the fuel consumption and electric current generated by the thermoelectric modules. On this basis, the power of the ATEG and its impact on overall engine efficiency were determined.
Road vehicle emission factors development: A review
NASA Astrophysics Data System (ADS)
Franco, Vicente; Kousoulidou, Marina; Muntean, Marilena; Ntziachristos, Leonidas; Hausberger, Stefan; Dilara, Panagiota
2013-05-01
Pollutant emissions need to be accurately estimated to ensure that air quality plans are designed and implemented appropriately. Emission factors (EFs) are empirical functional relations between pollutant emissions and the activity that causes them. In this review article, the techniques used to measure road vehicle emissions are examined in relation to the development of EFs found in emission models used to produce emission inventories. The emission measurement techniques covered include those most widely used for road vehicle emissions data collection, namely chassis and engine dynamometer measurements, remote sensing, road tunnel studies and portable emission measurements systems (PEMS). The main advantages and disadvantages of each method with regards to emissions modelling are presented. A review of the ways in which EFs may be derived from test data is also performed, with a clear distinction between data obtained under controlled conditions (engine and chassis dynamometer measurements using standard driving cycles) and measurements under real-world operation.
Effects of Induction-System Icing on Aircraft-Engine Operating Characteristics
NASA Technical Reports Server (NTRS)
Stevens, Howard C., Jr.
1947-01-01
An investigation was conducted on a multicylinder aircraft engine on a dynamometer stand to determine the effect of induction-system icing on engine operating characteristics and to compare the results with those of a previous laboratory investigation in which only the carburetor and the engine-stage supercharger assembly from the engine were used. The experiments were conducted at simulated glide power, low cruise power, and normal rated power through a range of humidity ratios and air temperatures at approximately sea-level pressure. Induction-system icing was found to occur within approximately the same limits as those established by the previous laboratory investigation after making suitable allowances for the difference in fuel volatility and throttle angles. Rough operation of the engine was experienced when ice caused a marked reduction in the air flow. Photographs of typical ice formations from this investigation indicate close similarity to icing previously observed in the laboratory.
Diesel bus emissions measured in a tunnel study.
Jamriska, Milan; Morawska, Lidia; Thomas, Steven; He, Congrong
2004-12-15
The emission factors of a bus fleet consisting of approximately 300 diesel-powered buses were measured in a tunnel study under well-controlled conditions during a 2-d monitoring campaign in Brisbane. Particle number and mass concentration levels of submicrometer particles and PM2.5 were monitored by SMPS and DustTrak instruments at the tunnel's entrance and exit, respectively. Correlation between DustTrak and TEOM response to diesel emissions was assessed, and the DustTrak results were recalculated into TEOM equivalent data. The mean value of the number and mass emission factors was (3.11+/-2.41) x 10(14) particles km(-1) for submicrometer particles and 583+/-451 mg km(-1) for PM2.5 (DustTrak), respectively. TEOM PM2.5 equivalent emission factor was 267+/-207 mg km(-1). The results are in good agreement with the emission factors determined from steady-state dynamometer testing of 12 buses from the same Brisbane City bus fleet. The results indicate that when carefully designed, both approaches, the dynamometer and on-road studies, can provide comparable results, applicable for the assessment of the effect of traffic emissions on airborne particle pollution. A brief overview of emission factors determined from other on-road and dynamometer studies reported in the literature as well as with the regulatory values used for the vehicle emission inventory assessment is presented and compared with the results obtained in this study.
Wang, Zhe; Lv, Haoliang; Zhou, Xiaojun; Chen, Zhaomeng; Yang, Yong
2018-06-21
Dual-motor Electric Drive Tracked Vehicles (DDTVs) have attracted increasing attention due to their high transmission efficiency and economical fuel consumption. A test bench for the development and validation of new DDTV technologies is necessary and urgent. How to load the vehicle on a DDTV test bench exactly the same as on a real road is a crucial issue when designing the bench. This paper proposes a novel dynamic load emulation method to address this problem. The method adopts dual dynamometers to simulate both the road load and the inertia load that are imposed on the dual independent drive systems. The vehicle’s total inertia equivalent to the drive wheels is calculated with separate consideration of vehicle body, tracks and road wheels to obtain a more accurate inertia load. A speed tracking control strategy with feedforward compensation is implemented to control the dual dynamometers, so as to make the real-time dynamic load emulation possible. Additionally, a MATLAB/Simulink model of the test bench is built based on a dynamics analysis of the platform. Experiments are finally carried out on this test bench under different test conditions. The outcomes show that the proposed load emulation method is effective, and has good robustness and adaptability to complex driving conditions. Besides, the accuracy of the established test bench model is also demonstrated by comparing the results obtained from the simulation model and experiments.
Code of Federal Regulations, 2012 CFR
2012-07-01
... power requirements to roadload dynamometer requirements. AC2 simulates, in standard test cell ambient...)(i) (A) and (B) are replaced with 76 °F and 50 grains of water/pound of dry air and the solar heat...)(5)(i) (A) and (B) are replaced with 76 °F and 50 grains of water/pound of dry air and the solar heat...
Code of Federal Regulations, 2013 CFR
2013-07-01
... power requirements to roadload dynamometer requirements. AC2 simulates, in standard test cell ambient...)(i) (A) and (B) are replaced with 76 °F and 50 grains of water/pound of dry air and the solar heat...)(5)(i) (A) and (B) are replaced with 76 °F and 50 grains of water/pound of dry air and the solar heat...
DOT National Transportation Integrated Search
1973-11-01
The exhaust emission concentrations from three GM6-71's and a Cummins VT-350 diesel engines were measured on a dynamometer as a function of engine load. The GM6-71 engines were newly rebuilt by the Coast Guard; the Cummins Engine was in used conditio...
NASA Technical Reports Server (NTRS)
1979-01-01
Report characterizes state-of-the-art electric and hybrid (combined electric and heat engine) vehicles. Performance data for representative number of these vehicles were obtained from track and dynamometer tests. User experience information was obtained from fleet operators and individual owners of electric vehicles. Data on performance and physical characteristics of large number of vehicles were obtained from manufacturers and available literature.
40 CFR 86.1318-84 - Engine dynamometer system calibrations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Engine dynamometer system calibrations...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate...
40 CFR 86.1318-84 - Engine dynamometer system calibrations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Engine dynamometer system calibrations...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate...
40 CFR 86.1318-84 - Engine dynamometer system calibrations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Engine dynamometer system calibrations...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate...
40 CFR 86.1318-84 - Engine dynamometer system calibrations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Engine dynamometer system calibrations...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate...
Design and analysis of a hemi-anechoic chamber at Michigan Technological University
NASA Astrophysics Data System (ADS)
Dreyer, Jason; Jangale, Ashish; Rao, Mohan D.
2005-09-01
A four-wheel chassis roll dynamometer test facility was installed on the campus of Michigan Technological University (MTU). The chassis dynamometer was enclosed in a soundproof hem-anechoic room in order to conduct noise radiation measurements on test vehicles. All surfaces of the room, except the floor and control room window, were acoustically treated with donated tetrahedral acoustic cones and panels. The acoustic absorption properties of these materials were characterized through reverberation chamber and impedance tube testing, and the effects of air gaps, cone orientation, and cone mounting materials were qualitatively evaluated. The design of the wall, ceiling, and door treatments of the chamber was based on the sound absorption properties of these materials, in addition to spatial constraints and cost considerations. The treated chamber acoustics were predicted based on the amount of acoustic material that could be applied to given chamber dimensions and would still preserve the functionality of the room. These predictions were validated through evaluation of the actual room treatment based on average reverberation time at 100-Hz third-octave band, free sound field characteristic 6-dB reduction in sound pressure level (SPL) per doubling in distance from source, noise reduction at the chamber boundaries, and background SPL Noise Criteria (NC) Rating.
Nascimento, N A Perigo; Moreira, P F P; Marin, R V; Moreira, L D F; Castro, M Lazaretti; Santos, C A F; Filho, C M A; Cendoroglo, M Seabra
2016-04-01
The aim of this study was to investigate if there is a relation among 25(OH)D, aquatic training, and multifunctional fitness on functional performance of elderly woman from the community. Cross-sectional study. Community. We evaluated elderly women aged ≥ 60 years (67±5 years old). One-hundred eighty were engaged in aquatic training (AT), 119 in multifunctional fitness (MF) for at least one year, and sedentary group (SED) with 162 independent elderly women from the community centers who had not practicing any regular physical exercise at least one year before. Timed up-and-go (TUG), 2-minute step test (2MST), 30-second chair stand (CS), arm curl (AC), functional reach test (FRT), unipedal balance test (UB) with visual control, handgrip right (HR) and handgrip left (HL) portable dynamometer for strength hip flexors (Hip strength) and knee extensors (Knee strength), serum 25(OH)D, intact parathyroid hormone (PTH), and creatinine clearance. Physical and functional tests showed differences among the three groups (ST; TUG, CS, AC, FR and USB = p <0.001). The PTH and the TUG test correlated inversely with 25(OH)D (r = -0.29 - p <0.001/ r = - 0.16 - p <0.001), also between 25(OH)D and BMI for AT and MF groups respectively (r= -0,15; p=0,04/ r= - 0,19; p=0,036). The AC test showed positive correlation (r = 0, 1 - p <0.001). The age and 25(OH)D were controlled and assumed to be a covariates in the statistical analysis that employed ANCOVA. There was difference on the performance of TUG test (p= 0.049). TUG performance was associated with age, exercise type and serum levels of 25(OH)D. The 25(OH)D insufficiency was common in elderly women from subtropical areas.
Felicio, Diogo Carvalho; Pereira, Daniele Sirineu; Assumpção, Alexandra Miranda; de Jesus-Moraleida, Fabianna Resende; de Queiroz, Barbara Zille; da Silva, Juscelio Pereira; de Brito Rosa, Naysa Maciel; Dias, João Marcos Domingues; Pereira, Leani Souza Máximo
2014-01-01
To investigate the correlation between handgrip strength and performance of knee flexor and extensor muscles determined using an isokinetic dynamometer in community-dwelling elderly women. This was a cross-sectional study. Sample selection for the study was made by convenience, and 221 (71.07 ± 4.93 years) community-dwelling elderly women were included. Knee flexor and extensor muscle performance was measured using an isokinetic dynamometer Biodex System 3 Pro. The isokinetic variables chosen for analysis were peak torque, peak torque/bodyweight, total work/bodyweight, total work, average power, and agonist/antagonist ratio at the angular velocities of 60°/s and 180°/s. Assessment of handgrip strength was carried out using the Jamar dynamometer. Spearman's correlation coefficient was calculated to identify intervariable correlations. Only knee flexor peak torque (60°/s) and average power (60°/s), and knee extensor peak torque (180°/s) and total work (180°/s) were significantly (P < 0.05), yet poorly, correlated with handgrip strength (r < 0.30). The majority of analyses did not show any correlation between variables assessed by isokinetic dynamometer and handgrip dynamometer. Caution is required when generalizing handgrip strength as a predictor of global muscle strength in community-dwelling elderly women. © 2013 Japan Geriatrics Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tibbitts, G.A.; DeLafosse, P.H.; Black, A.
1980-07-01
Four main areas of development for the project are covered: design and fabrication of a dynamometer and a mud cooling system for the Bearing-Seal Package Test Facility; modification of the Bearing-Seal Package Test Facility based on test results; testing of new lubricant samples from Pacer Lubricants, Inc., in the Terra Tek High Temperature Lubricant Tester; and testing of new seal types in the Terra Tek Sea Tester. The Maurer Engineering Report, Semi-Annual Progress Report on Improvement of Downhole Motor Bearings and Seals by Jeff L. Barnwell, has been included as Appendix B.
NASA Astrophysics Data System (ADS)
Hagino, Hiroyuki; Oyama, Motoaki; Sasaki, Sousuke
2016-04-01
To measure driving-distance-based mass emission factors for airborne brake wear particulate matter (PM; i.e., brake wear particles) related to the non-asbestos organic friction of brake assembly materials (pads and lining), and to characterize the components of brake wear particles, a brake wear dynamometer with a constant-volume sampling system was developed. Only a limited number of studies have investigated brake emissions under urban city driving cycles that correspond to the tailpipe emission test (i.e., JC08 or JE05 mode of Japanese tailpipe emission test cycles). The tests were performed using two passenger cars and one middle-class truck. The observed airborne brake wear particle emissions ranged from 0.04 to 1.4 mg/km/vehicle for PM10 (particles up to 10 μm (in size), and from 0.04 to 1.2 mg/km/vehicle for PM2.5. The proportion of brake wear debris emitted as airborne brake wear particles was 2-21% of the mass of wear. Oxygenated carbonaceous components were included in the airborne PM but not in the original friction material, which indicates that changes in carbon composition occurred during the abrasion process. Furthermore, this study identified the key tracers of brake wear particles (e.g., Fe, Cu, Ba, and Sb) at emission levels comparable to traffic-related atmospheric environments.
Franco, Vicente; Zacharopoulou, Theodora; Hammer, Jan; Schmidt, Helge; Mock, Peter; Weiss, Martin; Samaras, Zissis
2016-12-06
Hybridization offers great potential for decreasing pollutant and carbon dioxide emissions of diesel cars. However, an assessment of the real-world emissions performance of modern diesel hybrids is missing. Here, we test three diesel-hybrid cars on the road and benchmark our findings with two cars against tests on the chassis dynamometer and model simulations. The pollutant emissions of the two cars tested on the chassis dynamometer were in compliance with the relevant Euro standards over the New European Driving Cycle and Worldwide harmonized Light vehicles Test Procedure. On the road, all three diesel-hybrids exceeded the regulatory NO x limits (average exceedance for all trips: +150% for the Volvo, +510% for the Peugeot, and +550% for the Mercedes-Benz) and also showed elevated on-road CO 2 emissions (average exceedance of certification values: +178, +77, and +52%, respectively). These findings point to a wide discrepancy between certified and on-road CO 2 and suggest that hybridization alone is insufficient to achieve low-NO x emissions of diesel powertrains. Instead, our simulation suggests that properly calibrated selective catalytic reduction filter and lean-NO x trap after-treatment technologies can reduce the on-road NO x emissions to 0.023 and 0.068 g/km on average, respectively, well below the Euro 6 limit (0.080 g/km).
40 CFR 86.1308-84 - Dynamometer and engine equipment specifications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... technique involves the calibration of a master load cell (i.e., dynamometer case load cell). This... hydraulically actuated precalibrated master load cell. This calibration is then transferred to the flywheel torque measuring device. The technique involves the following steps: (i) A master load cell shall be...
40 CFR 86.1308-84 - Dynamometer and engine equipment specifications.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Dynamometer and engine equipment... (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate...
40 CFR 86.1237-85 - Dynamometer runs.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Evaporative... or pushed onto the dynamometer; however, if driven, the period of engine operation between the end of... manner that it is not exposed to precipitation (e.g., rain or dew). (b) The following steps shall be...
40 CFR 86.1316-94 - Calibrations; frequency and overview.
Code of Federal Regulations, 2012 CFR
2012-07-01
... through 86.1324. (2) Calibrate the engine dynamometer flywheel torque and speed measurement transducers... torque feedback signal at steady-state conditions by comparing: (i) Shaft torque feedback to dynamometer beam load; or (ii) By comparing in-line torque to armature current; or (iii) By checking the in-line...
40 CFR 86.1316-94 - Calibrations; frequency and overview.
Code of Federal Regulations, 2011 CFR
2011-07-01
... through 86.1324. (2) Calibrate the engine dynamometer flywheel torque and speed measurement transducers... torque feedback signal at steady-state conditions by comparing: (i) Shaft torque feedback to dynamometer beam load; or (ii) By comparing in-line torque to armature current; or (iii) By checking the in-line...
40 CFR 89.307 - Dynamometer calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... instructions for initial start-up and basic operating adjustments. (b) Check the dynamometer torque measurement... transfer standard may be used to verify the torque measurement system. (1) The master load-cell and read... master load-cell for each in-use range used. (5) The in-use torque measurement must be within 2 percent...
40 CFR 86.1316-94 - Calibrations; frequency and overview.
Code of Federal Regulations, 2010 CFR
2010-07-01
... through 86.1324. (2) Calibrate the engine dynamometer flywheel torque and speed measurement transducers... torque feedback signal at steady-state conditions by comparing: (i) Shaft torque feedback to dynamometer beam load; or (ii) By comparing in-line torque to armature current; or (iii) By checking the in-line...
40 CFR 86.1316-94 - Calibrations; frequency and overview.
Code of Federal Regulations, 2013 CFR
2013-07-01
... through 86.1324. (2) Calibrate the engine dynamometer flywheel torque and speed measurement transducers... torque feedback signal at steady-state conditions by comparing: (i) Shaft torque feedback to dynamometer beam load; or (ii) By comparing in-line torque to armature current; or (iii) By checking the in-line...
Looking northeast from Test Stand 'A' superstructure towards Test Stand ...
Looking northeast from Test Stand 'A' superstructure towards Test Stand 'D' tower (4223/E-24, left background), Test Stand 'C' tower (4217/E-18, center), and Test Stand 'B' (4215/E-16, right foreground). - Jet Propulsion Laboratory Edwards Facility, Edwards Air Force Base, Boron, Kern County, CA
Ice Hockey Players Using a Weighted Implement when Training on the Ice: A Randomized Control Trial
ERIC Educational Resources Information Center
Stark, Timothy W.; Tvoric, Bojan; Walker, Bruce; Noonan, Dom; Sibla, Janeene
2009-01-01
The purpose of this study was to investigate the potential for improving hockey players' performance using a weighted implement on the ice. Forty-eight players were tested using a grip strength dynamometer. They also were assessed on their abilities to stick-handle. The participants were randomly placed into a control or research group. The…
40 CFR 86.160-00 - Exhaust emission test procedure for SC03 emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2, CH4, and NOX. (b) Dynamometer activities. (1) All...
40 CFR 86.160-00 - Exhaust emission test procedure for SC03 emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2, CH4, and NOX. (b) Dynamometer activities. (1) All...
40 CFR 86.160-00 - Exhaust emission test procedure for SC03 emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2, CH4, and NOX. (b) Dynamometer activities. (1) All...
Carbonaceous PM2.5 emitted from light-duty vehicles operating on low-level ethanol fuel blends.
This study aims to examine carbonaceous aerosol emissions from three Tier 2-certified 2008 model year LDVs burning e0, e10, and e85 fuel blends at -7°C and 24°C. The LDVs were tested on an electric chasis dynamometer using the LA-92 Urban Driving Cycle (UDC). Exhaust was ...
Thiruvengadam, Arvind; Besch, Marc C; Thiruvengadam, Pragalath; Pradhan, Saroj; Carder, Daniel; Kappanna, Hemanth; Gautam, Mridul; Oshinuga, Adewale; Hogo, Henry; Miyasato, Matt
2015-04-21
Chassis dynamometer emissions testing of 11 heavy-duty goods movement vehicles, including diesel, natural gas, and dual-fuel technology, compliant with US-EPA 2010 emissions standard were conducted. Results of the study show that three-way catalyst (TWC) equipped stoichiometric natural gas vehicles emit 96% lower NOx emissions as compared to selective catalytic reduction (SCR) equipped diesel vehicles. Characteristics of drayage truck vocation, represented by the near-dock and local drayage driving cycles, were linked to high NOx emissions from diesel vehicles equipped with a SCR. Exhaust gas temperatures below 250 °C, for more than 95% duration of the local and near-dock driving cycles, resulted in minimal SCR activity. The low percentage of activity SCR over the local and near-dock cycles contributed to a brake-specific NOx emissions that were 5-7 times higher than in-use certification limit. The study also illustrated the differences between emissions rate measured from chassis dynamometer testing and prediction from the EMFAC model. The results of the study emphasize the need for model inputs relative to SCR performance as a function of driving cycle and engine operation characteristics.
BIOMECHANICAL DIFFERENCES IN BRAZILIAN JIU-JITSU ATHLETES: THE ROLE OF COMBAT STYLE.
Lima, Pedro Olavo de Paula; Lima, Alane Almeida; Coelho, Anita Camila Sampaio; Lima, Yuri Lopes; Almeida, Gabriel Peixoto Leão; Bezerra, Márcio Almeida; de Oliveira, Rodrigo Ribeiro
2017-02-01
Brazilian Jiu-Jitsu (BJJ) athletes can be divided into two combat styles: pass fighters (PFs) and guard fighters (GFs). Flexibility of the posterior chain muscles is highly necessary in these athletes, especially in GFs. On the other hand, isometric strength of the trunk extensors is required in PFs. Handgrip strength is important in holding the kimono of the opponent, and symmetrical lower-limb strength is important for the prevention of injuries due to the overload caused by training. The aim of this study was to compare the biomechanical profiles of BJJ athletes with different combat styles using the following outcome measures: flexibility, trunk extensor isometric endurance, postural balance, handgrip isometric endurance and lower-limb muscle strength. A cross-sectional study was conducted using 19 GFs and 19 PFs. The sit-and-reach test was used to evaluate the flexibility of the posterior chain muscles. The Biodex Balance System® was used to evaluate balance. A handgrip dynamometer and a dorsal dynamometer were used to evaluate handgrip and trunk extensor endurance, respectively. Quadriceps and hamstring strength were evaluated with an isokinetic dynamometer at 60 °/s. No differences were observed between groups in terms of flexibility, balance, handgrip isometric endurance or quadriceps and hamstring strength; however, PFs (81.33) showed more isometric trunk extension endurance than GFs (68.85) ( p = 0.02). Both groups had low values for hamstring/quadriceps ratio. No significant biomechanical differences were observed between PFs and GFs. 2b.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gevorgian, Vahan
The National Renewable Energy Laboratory (NREL) and DONG Energy are interested in collaborating for the development of control algorithms, modeling, and grid simulator testing of wind turbine generator systems involving NWTC's advanced Controllable Grid Interface (CGI). NREL and DONG Energy will work together to develop control algorithms, models, test methods, and protocols involving NREL's CGI, as well as appropriate data acquisition systems for grid simulation testing. The CRADA also includes work on joint publication of results achieved from modeling and testing efforts. Further, DONG Energy will send staff to NREL on a long-term basis for collaborative work including modeling andmore » testing. NREL will send staff to DONG Energy on a short-term basis to visit wind power sites and participate in meetings relevant to this collaborative effort. DOE has provided NREL with over 10 years of support in developing custom facilities and capabilities to enable testing of full-scale integrated wind turbine drivetrain systems in accordance with the needs of the US wind industry. NREL currently operates a 2.5MW dynamometer and is in the processes of commissioning a 5MW dynamometer and a grid simulator (referred to as a 'Controllable Grid Interface' or CGI). DONG Energy is the market leader in offshore wind power development, with currently over 1 GW of on- and offshore wind power in operation, and 1.3 GW under construction. DONG Energy has on-going R&D projects involving high voltage DC (HVDC) transmission.« less
Lip, Ryan W T; Fong, Shirley S M; Ng, Shamay S M; Liu, Karen P Y; Guo, X
2015-03-01
[Purpose] The aim of this study was to investigate the effects of Ving Tsun (VT) Chinese martial art training on radial bone strength, upper- and lower-limb muscular strength, shoulder joint mobility, balance performance, and self-efficacy in elderly participants. [Subjects and Methods] Twelve seniors voluntarily joined the VT training group, and twenty-seven seniors voluntarily joined the control group. The VT group received VT training for three months, while the control group received no training. The bone strength of the distal radius was assessed using an ultrasound bone sonometer. Muscular strength in the limbs was evaluated using a Jamar handgrip dynamometer and the five times sit-to-stand test. Shoulder joint mobility was examined using a goniometer. Balance performance and self-efficacy were evaluated using the Berg Balance Scale and the Chinese version of the Activities-specific Balance Confidence Scale, respectively. [Results] The results revealed a nonsignificant group-by-time interaction effect, group effect, and time effect for all outcome variables. However, general trends of maintenance or improvement in all outcome parameters were observed to a greater extent in the VT group than in the control group. [Conclusion] VT training might be a potential fall-prevention exercise that can be used to maintain general physique, balance, and confidence in the elderly population. A further randomized controlled trial is needed to confirm this postulation.
Lip, Ryan W.T.; Fong, Shirley S.M.; Ng, Shamay S.M.; Liu, Karen P.Y.; Guo, X.
2015-01-01
[Purpose] The aim of this study was to investigate the effects of Ving Tsun (VT) Chinese martial art training on radial bone strength, upper- and lower-limb muscular strength, shoulder joint mobility, balance performance, and self-efficacy in elderly participants. [Subjects and Methods] Twelve seniors voluntarily joined the VT training group, and twenty-seven seniors voluntarily joined the control group. The VT group received VT training for three months, while the control group received no training. The bone strength of the distal radius was assessed using an ultrasound bone sonometer. Muscular strength in the limbs was evaluated using a Jamar handgrip dynamometer and the five times sit-to-stand test. Shoulder joint mobility was examined using a goniometer. Balance performance and self-efficacy were evaluated using the Berg Balance Scale and the Chinese version of the Activities-specific Balance Confidence Scale, respectively. [Results] The results revealed a nonsignificant group-by-time interaction effect, group effect, and time effect for all outcome variables. However, general trends of maintenance or improvement in all outcome parameters were observed to a greater extent in the VT group than in the control group. [Conclusion] VT training might be a potential fall-prevention exercise that can be used to maintain general physique, balance, and confidence in the elderly population. A further randomized controlled trial is needed to confirm this postulation. PMID:25931704
Dynamometer Research Facilities | Wind | NREL
drivetrains by replacing the rotor and blades of a turbine with a powerful motor. The National Renewable -horsepower variable-speed induction motor, with AC grid connections of 120, 240, and 480 volts (V) and a dynamometer features a 3,351-horsepower (hp), 415-amp AC induction motor with variable-frequency drive that
40 CFR 86.515-78 - EPA urban dynamometer driving schedule.
Code of Federal Regulations, 2010 CFR
2010-07-01
... I(b) (b) The speed tolerance at any given time on the dynamometer driving schedule prescribed in... than the tolerances (such as may occur during gear changes) are acceptable provided they occur for less... requirements of § 86.532 the speed tolerance shall be as specified above, except that the upper and lower...
40 CFR 1066.220 - Linearity verification for chassis dynamometer systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... dynamometer speed and torque at least as frequently as indicated in Table 1 of § 1066.215. The intent of... linear regression and the linearity criteria specified in Table 1 of this section. (b) Performance requirements. If a measurement system does not meet the applicable linearity criteria in Table 1 of this...
40 CFR 1066.260 - Parasitic friction compensation evaluation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... also first verify the dynamometer's parasitic loss curve as specified in § 1066.255. (c) Procedure. Use...-load coefficients A, B, and C set to 0. Set the dynamometer to speed-control mode with a target speed... friction compensation is executed perfectly, there will be no change in speed during the measurement...
40 CFR 1066.260 - Parasitic friction compensation evaluation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... also first verify the dynamometer's parasitic loss curve as specified in § 1066.255. (c) Procedure. Use...-load coefficients A, B, and C set to 0. Set the dynamometer to speed-control mode with a target speed... friction compensation is executed perfectly, there will be no change in speed during the measurement...
40 CFR 1066.260 - Parasitic friction compensation evaluation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... and 1066.240. You must also first verify the dynamometer's parasitic loss curve as specified in § 1066... with the road-load coefficients A, B, and C set to 0. Set the dynamometer to speed-control mode with a... times. If friction compensation is executed perfectly, there will be no change in speed during the...