Sample records for dynamometer torque cell

  1. 40 CFR 90.306 - Dynamometer torque cell calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Dynamometer torque cell calibration... Emission Test Equipment Provisions § 90.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used...-cell or transfer standard may be used to verify the torque measurement system. (1) The master load-cell...

  2. 40 CFR 90.306 - Dynamometer torque cell calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Dynamometer torque cell calibration... Emission Test Equipment Provisions § 90.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used...-cell or transfer standard may be used to verify the torque measurement system. (1) The master load-cell...

  3. 40 CFR 90.306 - Dynamometer torque cell calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Dynamometer torque cell calibration... Emission Test Equipment Provisions § 90.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used...-cell or transfer standard may be used to verify the torque measurement system. (1) The master load-cell...

  4. 40 CFR 90.306 - Dynamometer torque cell calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Dynamometer torque cell calibration... Emission Test Equipment Provisions § 90.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used...-cell or transfer standard may be used to verify the torque measurement system. (1) The master load-cell...

  5. 40 CFR 91.306 - Dynamometer torque cell calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Dynamometer torque cell calibration... Provisions § 91.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used to convert a weight or a... with the adjusted or repaired system. (b) Option. A master load-cell or transfer standard may be used...

  6. 40 CFR 91.306 - Dynamometer torque cell calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Dynamometer torque cell calibration... Provisions § 91.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used to convert a weight or a... with the adjusted or repaired system. (b) Option. A master load-cell or transfer standard may be used...

  7. 40 CFR 91.306 - Dynamometer torque cell calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Dynamometer torque cell calibration... Provisions § 91.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used to convert a weight or a... with the adjusted or repaired system. (b) Option. A master load-cell or transfer standard may be used...

  8. 40 CFR 91.306 - Dynamometer torque cell calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Dynamometer torque cell calibration... Provisions § 91.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used to convert a weight or a... with the adjusted or repaired system. (b) Option. A master load-cell or transfer standard may be used...

  9. 40 CFR 90.306 - Dynamometer torque cell calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Dynamometer torque cell calibration. 90... Equipment Provisions § 90.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used to convert a... (a)(6) of this section with the adjusted or repaired system. (b) Option. A master load-cell or...

  10. 40 CFR 91.306 - Dynamometer torque cell calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Dynamometer torque cell calibration. 91....306 Dynamometer torque cell calibration. (a)(1) Any lever arm used to convert a weight or a force... with the adjusted or repaired system. (b) Option. A master load-cell or transfer standard may be used...

  11. Comparing passive angle-torque curves recorded simultaneously with a load cell versus an isokinetic dynamometer during dorsiflexion stretch tolerance assessments.

    PubMed

    Buckner, Samuel L; Jenkins, Nathaniel D M; Costa, Pablo B; Ryan, Eric D; Herda, Trent J; Cramer, Joel T

    2015-05-01

    The purpose of the present study was to compare the passive angle-torque curves and the passive stiffness (PS, N m °(-)(1)) values recorded simultaneously from a load cell versus an isokinetic dynamometer during dorsiflexion stretch tolerance assessments in vivo. Nine healthy men (mean ± SD age = 21.4 ± 1.6 years) completed stretch tolerance assessments on a custom-built apparatus where passive torque was measured simultaneously from an isokinetic dynamometer and a load cell. Passive torque values that corresponded with the last 10° of dorsiflexion, verified by surface electromyographic amplitude, were analyzed for each device (θ1, θ2, θ3, …, θ10). Passive torque values measured with the load cell were greater (p ≤ 0.05) than the dynamometer torque values for θ4 through θ10. There were more statistical differentiations among joint angles for passive torque measured by the load cell, and the load cell measured a greater (p ≤ 0.01) increase in passive torque and PS than the isokinetic dynamometer. These findings suggested that when examining the angle-torque curves from passive dorsiflexion stretch tolerance tests, a load cell placed under the distal end of the foot may be more sensitive than the torque recorded from an isokinetic dynamometer. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  12. 40 CFR 89.307 - Dynamometer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... master load-cell for each in-use range used. (5) The in-use torque measurement must be within 2 percent... torque measurement for each range used by the following method: (1) Warm up the dynamometer following the dynamometer manufacturer's specifications. (2) Determine the dynamometer calibration moment arm (a distance...

  13. 40 CFR 89.307 - Dynamometer calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... instructions for initial start-up and basic operating adjustments. (b) Check the dynamometer torque measurement... transfer standard may be used to verify the torque measurement system. (1) The master load-cell and read... master load-cell for each in-use range used. (5) The in-use torque measurement must be within 2 percent...

  14. 40 CFR 89.307 - Dynamometer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... torque measurement for each range used by the following method: (1) Warm up the dynamometer following the... transfer standard may be used to verify the torque measurement system. (1) The master load-cell and read... master load-cell for each in-use range used. (5) The in-use torque measurement must be within 2 percent...

  15. 40 CFR 89.307 - Dynamometer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... torque measurement for each range used by the following method: (1) Warm up the dynamometer following the... transfer standard may be used to verify the torque measurement system. (1) The master load-cell and read... master load-cell for each in-use range used. (5) The in-use torque measurement must be within 2 percent...

  16. 40 CFR 89.307 - Dynamometer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... torque measurement for each range used by the following method: (1) Warm up the dynamometer following the... transfer standard may be used to verify the torque measurement system. (1) The master load-cell and read... master load-cell for each in-use range used. (5) The in-use torque measurement must be within 2 percent...

  17. 40 CFR 86.333-79 - Dynamometer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... master load-cell for each in-use range used. (5) The in-use torque measurement must be within 2 percent... basic operating adjustments. (b) Check the dynamometer torque measurement for each range used by the following: (1) Warm up the dynamometer following the equipment manufacturer's specifications. (2) Determine...

  18. 40 CFR 86.333-79 - Dynamometer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... basic operating adjustments. (b) Check the dynamometer torque measurement for each range used by the... or transfer standard may be used to verify the in-use torque measurement system. (1) The master load... master load-cell for each in-use range used. (5) The in-use torque measurement must be within 2 percent...

  19. 40 CFR 86.333-79 - Dynamometer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... basic operating adjustments. (b) Check the dynamometer torque measurement for each range used by the... or transfer standard may be used to verify the in-use torque measurement system. (1) The master load... master load-cell for each in-use range used. (5) The in-use torque measurement must be within 2 percent...

  20. 40 CFR 86.333-79 - Dynamometer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... basic operating adjustments. (b) Check the dynamometer torque measurement for each range used by the... or transfer standard may be used to verify the in-use torque measurement system. (1) The master load... master load-cell for each in-use range used. (5) The in-use torque measurement must be within 2 percent...

  1. 40 CFR 86.1308-84 - Dynamometer and engine equipment specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... technique involves the calibration of a master load cell (i.e., dynamometer case load cell). This... hydraulically actuated precalibrated master load cell. This calibration is then transferred to the flywheel torque measuring device. The technique involves the following steps: (i) A master load cell shall be...

  2. 40 CFR 91.305 - Dynamometer specifications and calibration accuracy.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... specifications. (1) The dynamometer test stand and other instruments for measurement of engine speed and torque... accuracy. (1) The dynamometer test stand and other instruments for measurement of engine torque and speed...

  3. 40 CFR 91.305 - Dynamometer specifications and calibration accuracy.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... specifications. (1) The dynamometer test stand and other instruments for measurement of engine speed and torque... accuracy. (1) The dynamometer test stand and other instruments for measurement of engine torque and speed...

  4. 40 CFR 91.305 - Dynamometer specifications and calibration accuracy.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... specifications. (1) The dynamometer test stand and other instruments for measurement of engine speed and torque... accuracy. (1) The dynamometer test stand and other instruments for measurement of engine torque and speed...

  5. 40 CFR 91.305 - Dynamometer specifications and calibration accuracy.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... specifications. (1) The dynamometer test stand and other instruments for measurement of engine speed and torque... accuracy. (1) The dynamometer test stand and other instruments for measurement of engine torque and speed...

  6. 40 CFR 91.305 - Dynamometer specifications and calibration accuracy.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... specifications. (1) The dynamometer test stand and other instruments for measurement of engine speed and torque... accuracy. (1) The dynamometer test stand and other instruments for measurement of engine torque and speed...

  7. 40 CFR 86.1316-94 - Calibrations; frequency and overview.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... through 86.1324. (2) Calibrate the engine dynamometer flywheel torque and speed measurement transducers... torque feedback signal at steady-state conditions by comparing: (i) Shaft torque feedback to dynamometer beam load; or (ii) By comparing in-line torque to armature current; or (iii) By checking the in-line...

  8. 40 CFR 86.1316-94 - Calibrations; frequency and overview.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... through 86.1324. (2) Calibrate the engine dynamometer flywheel torque and speed measurement transducers... torque feedback signal at steady-state conditions by comparing: (i) Shaft torque feedback to dynamometer beam load; or (ii) By comparing in-line torque to armature current; or (iii) By checking the in-line...

  9. 40 CFR 86.1316-94 - Calibrations; frequency and overview.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... through 86.1324. (2) Calibrate the engine dynamometer flywheel torque and speed measurement transducers... torque feedback signal at steady-state conditions by comparing: (i) Shaft torque feedback to dynamometer beam load; or (ii) By comparing in-line torque to armature current; or (iii) By checking the in-line...

  10. 40 CFR 86.1316-94 - Calibrations; frequency and overview.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... through 86.1324. (2) Calibrate the engine dynamometer flywheel torque and speed measurement transducers... torque feedback signal at steady-state conditions by comparing: (i) Shaft torque feedback to dynamometer beam load; or (ii) By comparing in-line torque to armature current; or (iii) By checking the in-line...

  11. Validity of Torque-Data Collection at Multiple Sites: A Framework for Collaboration on Clinical-Outcomes Research in Sports Medicine.

    PubMed

    Kuenze, Christopher; Eltouhky, Moataz; Thomas, Abbey; Sutherlin, Mark; Hart, Joseph

    2016-05-01

    Collecting torque data using a multimode dynamometer is common in sports-medicine research. The error in torque measurements across multiple sites and dynamometers has not been established. To assess the validity of 2 calibration protocols across 3 dynamometers and the error associated with torque measurement for each system. Observational study. 3 university laboratories at separate institutions. 2 Biodex System 3 dynamometers and 1 Biodex System 4 dynamometer. System calibration was completed using the manufacturer-recommended single-weight method and an experimental calibration method using a series of progressive weights. Both calibration methods were compared with a manually calculated theoretical torque across a range of applied weights. Relative error, absolute error, and percent error were calculated at each weight. Each outcome variable was compared between systems using 95% confidence intervals across low (0-65 Nm), moderate (66-110 Nm), and high (111-165 Nm) torque categorizations. Calibration coefficients were established for each system using both calibration protocols. However, within each system the calibration coefficients generated using the single-weight (System 4 = 2.42 [0.90], System 3a = 1.37 [1.11], System 3b = -0.96 [1.45]) and experimental calibration protocols (System 4 = 3.95 [1.08], System 3a = -0.79 [1.23], System 3b = 2.31 [1.66]) were similar and displayed acceptable mean relative error compared with calculated theoretical torque values. Overall, percent error was greatest for all 3 systems in low-torque conditions (System 4 = 11.66% [6.39], System 3a = 6.82% [11.98], System 3b = 4.35% [9.49]). The System 4 significantly overestimated torque across all 3 weight increments, and the System 3b overestimated torque over the moderate-torque increment. Conversion of raw voltage to torque values using the single-calibration-weight method is valid and comparable to a more complex multiweight calibration process; however, it is clear that calibration must be done for each individual system to ensure accurate data collection.

  12. Enhanced precision of ankle torque measure with an open-unit dynamometer mounted with a 3D force-torque sensor.

    PubMed

    Toumi, A; Leteneur, S; Gillet, C; Debril, J-F; Decoufour, N; Barbier, F; Jakobi, J M; Simoneau-Buessinger, Emilie

    2015-11-01

    Many studies have focused on maximum torque exerted by ankle joint muscles during plantar flexion. While strength parameters are typically measured with isokinetic or isolated ankle dynamometers, these devices often present substantial limitations for the measurement of torque because they account for force in only 1 dimension (1D), and the device often constrains the body in a position that augments torque through counter movements. The purposes of this study were to determine the contribution of body position to ankle plantar-flexion torque and to assess the use of 1D and 3D torque sensors. A custom designed 'Booted, Open-Unit, Three dimension, Transportable, Ergometer' (B.O.T.T.E.) was used to quantify plantar flexion in two conditions: (1) when the participant was restrained within the unit (locked-unit) and (2) when the participant's position was independent of the ankle dynamometer (open-unit). Ten young males performed maximal voluntary isometric plantar-flexion contractions using the B.O.T.T.E. in open and locked-unit mechanical configurations. The B.O.T.T.E. was reliable with ICC higher than 0.90, and CV lower than 7 %. The plantar-flexion maximal resultant torque was significantly higher in the locked-unit compared with open-unit configuration (P < 0.001; +61 to +157 %) due to the addition of forces from the body being constrained within the testing device. A 1D compared with 3D torque sensor significantly underestimated the proper capacity of plantar-flexion torque production (P < 0.001; -37 to -60 %). Assessment of plantar-flexion torque should be performed with an open-unit dynamometer mounted with a 3D sensor that is exclusive of accessory muscles but inclusive of all ankle joint movements.

  13. Development of a precision, six-axis laboratory dynamometer

    NASA Technical Reports Server (NTRS)

    Champagne, P. J.; Cordova, S. A.; Jacoby, M. S.; Lorell, K. R.

    1992-01-01

    This paper describes the design, fabrication, test, and operation of a unique six axis force/torque dynamometer The specimen table used to hold components under test is supported in a full six axis kinematic mount. Support struts fabricated from high strength steel with special integral two axis flexures link the specimen table to the load cell transducers. Realtime force/torque coordinate transform, root mean squared calculation, and data averaging, and color six axis display with controllable scaling are provided by a specially programmed desktop computer. The extensive structural analysis and design optimization required to obtain a stiff, well damped, lightweight structure is described in detail. Geometric optimization of the kinematic mount and fabrication details of the struts are also described.

  14. Determination of torque speed current characteristics of a brushless DC motor by utilizing back-EMF of non-energized phase

    NASA Astrophysics Data System (ADS)

    Jang, G. H.; Yeom, J. H.; Kim, M. G.

    2007-03-01

    This paper presents a method to determine the torque constant and the torque-speed-current characteristics of a brushless DC (BLDC) motor by utilizing back-EMF variation of nonenergized phase. It also develops a BLDC motor controller with a digital signal processor (DSP) to monitor its current, voltage and speed in real time. Torque-speed-current characteristics of a BLDC motor are determined by using the proposed method and the developed controller. They are compared with the torque-speed-current characteristics measured by dynamometer experimentally. This research shows that the proposed method is an effective method to determine the torque constant and the torque-speed-current characteristics of the BLDC motor without using dynamometer.

  15. Poor correlation between handgrip strength and isokinetic performance of knee flexor and extensor muscles in community-dwelling elderly women.

    PubMed

    Felicio, Diogo Carvalho; Pereira, Daniele Sirineu; Assumpção, Alexandra Miranda; de Jesus-Moraleida, Fabianna Resende; de Queiroz, Barbara Zille; da Silva, Juscelio Pereira; de Brito Rosa, Naysa Maciel; Dias, João Marcos Domingues; Pereira, Leani Souza Máximo

    2014-01-01

    To investigate the correlation between handgrip strength and performance of knee flexor and extensor muscles determined using an isokinetic dynamometer in community-dwelling elderly women. This was a cross-sectional study. Sample selection for the study was made by convenience, and 221 (71.07 ± 4.93 years) community-dwelling elderly women were included. Knee flexor and extensor muscle performance was measured using an isokinetic dynamometer Biodex System 3 Pro. The isokinetic variables chosen for analysis were peak torque, peak torque/bodyweight, total work/bodyweight, total work, average power, and agonist/antagonist ratio at the angular velocities of 60°/s and 180°/s. Assessment of handgrip strength was carried out using the Jamar dynamometer. Spearman's correlation coefficient was calculated to identify intervariable correlations. Only knee flexor peak torque (60°/s) and average power (60°/s), and knee extensor peak torque (180°/s) and total work (180°/s) were significantly (P < 0.05), yet poorly, correlated with handgrip strength (r < 0.30). The majority of analyses did not show any correlation between variables assessed by isokinetic dynamometer and handgrip dynamometer. Caution is required when generalizing handgrip strength as a predictor of global muscle strength in community-dwelling elderly women. © 2013 Japan Geriatrics Society.

  16. 40 CFR 1066.240 - Torque transducer verification.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.240 Torque transducer verification. Verify torque-measurement systems by performing the verifications described in §§ 1066.270 and... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Torque transducer verification. 1066...

  17. The Direct Measurement of Engine Power on an Airplane in Flight with a Hub Type Dynamometer

    NASA Technical Reports Server (NTRS)

    Gove, W D; Green, M W

    1927-01-01

    This report describes tests made to obtain direct measurements of engine power in flight. Tests were made with a Bendemann hub dynamometer installed on a modified DH-4 Airplane, Liberty 12 Engine, to determine the suitability of this apparatus. This dynamometer unit, which was designed specially for use with a liberty 12 engine, is a special propeller hub in which is incorporated a system of pistons and cylinders interposed between the propeller and the engine crankshaft. The torque and thrust forces are balanced by fluid pressures, which are recorded by instruments in the cockpit. These tests have shown the suitability of this type of hub dynamometer for measurement of power in flight and for the determination of the torque and power coefficients of the propeller. (author)

  18. Torsional Vibration in the National Wind Technology Center’s 2.5-Megawatt Dynamometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sethuraman, Latha; Keller, Jonathan; Wallen, Robb

    2016-08-31

    This report documents the torsional drivetrain dynamics of the NWTC's 2.5-megawatt dynamometer as identified experimentally and as calculated using lumped parameter models using known inertia and stiffness parameters. The report is presented in two parts beginning with the identification of the primary torsional modes followed by the investigation of approaches to damp the torsional vibrations. The key mechanical parameters for the lumped parameter models and justification for the element grouping used in the derivation of the torsional modes are presented. The sensitivities of the torsional modes to different test article properties are discussed. The oscillations observed from the low-speed andmore » generator torque measurements were used to identify the extent of damping inherently achieved through active and passive compensation techniques. A simplified Simulink model of the dynamometer test article integrating the electro-mechanical power conversion and control features was established to emulate the torque behavior that was observed during testing. The torque response in the high-speed, low-speed, and generator shafts were tested and validated against experimental measurements involving step changes in load with the dynamometer operating under speed-regulation mode. The Simulink model serves as a ready reference to identify the torque sensitivities to various system parameters and to explore opportunities to improve torsional damping under different conditions.« less

  19. 40 CFR 90.305 - Dynamometer specifications and calibration accuracy.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (a) Dynamometer specifications. The dynamometer test stand and other instruments for measurement of speed and power output must meet the engine speed and torque accuracy requirements shown in Table 2 in... measurement of power output must meet the calibration frequency shown in Table 2 in Appendix A of this subpart...

  20. 40 CFR 90.305 - Dynamometer specifications and calibration accuracy.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (a) Dynamometer specifications. The dynamometer test stand and other instruments for measurement of speed and power output must meet the engine speed and torque accuracy requirements shown in Table 2 in... measurement of power output must meet the calibration frequency shown in Table 2 in Appendix A of this subpart...

  1. 40 CFR 90.305 - Dynamometer specifications and calibration accuracy.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... (a) Dynamometer specifications. The dynamometer test stand and other instruments for measurement of speed and power output must meet the engine speed and torque accuracy requirements shown in Table 2 in... measurement of power output must meet the calibration frequency shown in Table 2 in Appendix A of this subpart...

  2. 40 CFR 90.305 - Dynamometer specifications and calibration accuracy.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (a) Dynamometer specifications. The dynamometer test stand and other instruments for measurement of speed and power output must meet the engine speed and torque accuracy requirements shown in Table 2 in... measurement of power output must meet the calibration frequency shown in Table 2 in Appendix A of this subpart...

  3. 40 CFR 90.305 - Dynamometer specifications and calibration accuracy.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (a) Dynamometer specifications. The dynamometer test stand and other instruments for measurement of speed and power output must meet the engine speed and torque accuracy requirements shown in Table 2 in... measurement of power output must meet the calibration frequency shown in Table 2 in Appendix A of this subpart...

  4. 40 CFR 1066.240 - Torque transducer verification and calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.240 Torque transducer verification and calibration. Calibrate torque-measurement systems as described in 40 CFR 1065.310. ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Torque transducer verification and...

  5. 40 CFR 1066.240 - Torque transducer verification and calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.240 Torque transducer verification and calibration. Calibrate torque-measurement systems as described in 40 CFR 1065.310. ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Torque transducer verification and...

  6. 40 CFR 92.116 - Engine output measurement system calibrations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... calibration. (1) The engine flywheel torque and engine speed measurement transducers shall be calibrated with... performed with the dynamometer operating at a constant speed. The flywheel torque measurement device readout... practice requires that both devices have approximately equal useful ranges of torque measurement.) The...

  7. 40 CFR 92.116 - Engine output measurement system calibrations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... calibration. (1) The engine flywheel torque and engine speed measurement transducers shall be calibrated with... performed with the dynamometer operating at a constant speed. The flywheel torque measurement device readout... practice requires that both devices have approximately equal useful ranges of torque measurement.) The...

  8. 40 CFR 92.116 - Engine output measurement system calibrations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... calibration. (1) The engine flywheel torque and engine speed measurement transducers shall be calibrated with... performed with the dynamometer operating at a constant speed. The flywheel torque measurement device readout... practice requires that both devices have approximately equal useful ranges of torque measurement.) The...

  9. 40 CFR 92.116 - Engine output measurement system calibrations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... calibration. (1) The engine flywheel torque and engine speed measurement transducers shall be calibrated with... performed with the dynamometer operating at a constant speed. The flywheel torque measurement device readout... practice requires that both devices have approximately equal useful ranges of torque measurement.) The...

  10. 40 CFR 92.115 - Calibrations; frequency and overview.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... any maintenance which could alter calibration, calibrate the engine dynamometer flywheel torque and speed measurement transducers, as specified in § 92.116. (d) At least monthly or after any maintenance... (if used) shaft torque feedback signal at steady-state conditions by comparing: (1) Shaft torque...

  11. 40 CFR 92.115 - Calibrations; frequency and overview.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... any maintenance which could alter calibration, calibrate the engine dynamometer flywheel torque and speed measurement transducers, as specified in § 92.116. (d) At least monthly or after any maintenance... (if used) shaft torque feedback signal at steady-state conditions by comparing: (1) Shaft torque...

  12. 40 CFR 92.115 - Calibrations; frequency and overview.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... any maintenance which could alter calibration, calibrate the engine dynamometer flywheel torque and speed measurement transducers, as specified in § 92.116. (d) At least monthly or after any maintenance... (if used) shaft torque feedback signal at steady-state conditions by comparing: (1) Shaft torque...

  13. 40 CFR 92.115 - Calibrations; frequency and overview.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... any maintenance which could alter calibration, calibrate the engine dynamometer flywheel torque and speed measurement transducers, as specified in § 92.116. (d) At least monthly or after any maintenance... (if used) shaft torque feedback signal at steady-state conditions by comparing: (1) Shaft torque...

  14. Dynamic calibration of a wheelchair dynamometer.

    PubMed

    DiGiovine, C P; Cooper, R A; Boninger, M L

    2001-01-01

    The inertia and resistance of a wheelchair dynamometer must be determined in order to compare the results of one study to another, independent of the type of device used. The purpose of this study was to describe and implement a dynamic calibration test for characterizing the electro-mechanical properties of a dynamometer. The inertia, the viscous friction, the kinetic friction, the motor back-electromotive force constant, and the motor constant were calculated using three different methods. The methodology based on a dynamic calibration test along with a nonlinear regression analysis produced the best results. The coefficient of determination comparing the dynamometer model output to the measured angular velocity and torque was 0.999 for a ramp input and 0.989 for a sinusoidal input. The inertia and resistance were determined for the rollers and the wheelchair wheels. The calculation of the electro-mechanical parameters allows for the complete description of the propulsive torque produced by an individual, given only the angular velocity and acceleration. The measurement of the electro-mechanical properties of the dynamometer as well as the wheelchair/human system provides the information necessary to simulate real-world conditions.

  15. 40 CFR 86.1308-84 - Dynamometer and engine equipment specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....e., armature current, etc.) may be used for torque measurement provided that it can be shown that... a constant speed. The flywheel torque measurement device readout shall be calibrated to the master... approximately equal useful ranges of torque measurement.) The transfer calibration shall be performed in a...

  16. 40 CFR 86.1308-84 - Dynamometer and engine equipment specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....e., armature current, etc.) may be used for torque measurement provided that it can be shown that... a constant speed. The flywheel torque measurement device readout shall be calibrated to the master... approximately equal useful ranges of torque measurement.) The transfer calibration shall be performed in a...

  17. Torque and power outputs on different subjects during manual wheelchair propulsion under different conditions

    NASA Astrophysics Data System (ADS)

    Hwang, Seonhong; Kim, Seunghyeon; Son, Jongsang; Kim, Youngho

    2012-02-01

    Manual wheelchair users are at a high risk of pain and injuries to the upper extremities due to mechanical inefficiency of wheelchair propulsion motion. The kinetic analysis of the upper extremities during manual wheelchair propulsion in various conditions needed to be investigated. We developed and calibrated a wheelchair dynamometer for measuring kinetic parameters during propulsion. We utilized the dynamometer to investigate and compare the propulsion torque and power values of experienced and novice users under four different conditions. Experienced wheelchair users generated lower torques with more power than novice users and reacted alertly and sensitively to changing conditions. We expect that these basic methods and results may help to quantitatively evaluate the mechanical efficiency of manual wheelchair propulsion.

  18. 40 CFR 86.1333-90 - Transient test cycle generation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... zero percent speed specified in the engine dynamometer schedules (appendix I (f)(1), (f)(2), or (f)(3... feedback torque equal to zero (using, for example, clutch disengagement, speed to torque control switching... reference speed and reference torque are zero percent values. For each idle segment that is ten seconds or...

  19. 40 CFR 86.1333-90 - Transient test cycle generation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... zero percent speed specified in the engine dynamometer schedules (appendix I (f)(1), (f)(2), or (f)(3... feedback torque equal to zero (using, for example, clutch disengagement, speed to torque control switching... reference speed and reference torque are zero percent values. For each idle segment that is ten seconds or...

  20. 40 CFR 86.1333-90 - Transient test cycle generation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... zero percent speed specified in the engine dynamometer schedules (appendix I (f)(1), (f)(2), or (f)(3... feedback torque equal to zero (using, for example, clutch disengagement, speed to torque control switching... reference speed and reference torque are zero percent values. For each idle segment that is ten seconds or...

  1. Dyna Soars: Low Torque Measurement Dynamometer

    ERIC Educational Resources Information Center

    Dolph, Darrel A.

    2004-01-01

    Students in the Electronics Engineering Technology program at Pennsylvania College of Technology designed and built a computerized dynamometer platform for testing dc brushless motors. As the capstone experience for EET-320, Measurement and Tests course, students were divided into teams of four and were given three weeks to complete the project.…

  2. Validity of trunk extensor and flexor torque measurements using isokinetic dynamometry.

    PubMed

    Guilhem, Gaël; Giroux, Caroline; Couturier, Antoine; Maffiuletti, Nicola A

    2014-12-01

    This study aimed to evaluate the validity and test-retest reliability of trunk muscle strength testing performed with a latest-generation isokinetic dynamometer. Eccentric, isometric, and concentric peak torque of the trunk flexor and extensor muscles was measured in 15 healthy subjects. Muscle cross sectional area (CSA) and surface electromyographic (EMG) activity were respectively correlated to peak torque and submaximal isometric torque for erector spinae and rectus abdominis muscles. Reliability of peak torque measurements was determined during test and retest sessions. Significant correlations were consistently observed between muscle CSA and peak torque for all contraction types (r=0.74-0.85; P<0.001) and between EMG activity and submaximal isometric torque (r ⩾ 0.99; P<0.05), for both extensor and flexor muscles. Intraclass correlation coefficients were comprised between 0.87 and 0.95, and standard errors of measurement were lower than 9% for all contraction modes. The mean difference in peak torque between test and retest ranged from -3.7% to 3.7% with no significant mean directional bias. Overall, our findings establish the validity of torque measurements using the tested trunk module. Also considering the excellent test-retest reliability of peak torque measurements, we conclude that this latest-generation isokinetic dynamometer could be used with confidence to evaluate trunk muscle function for clinical or athletic purposes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. 40 CFR 1066.220 - Linearity verification for chassis dynamometer systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... dynamometer speed and torque at least as frequently as indicated in Table 1 of § 1066.215. The intent of... linear regression and the linearity criteria specified in Table 1 of this section. (b) Performance requirements. If a measurement system does not meet the applicable linearity criteria in Table 1 of this...

  4. 40 CFR 86.341-79 - Diesel engine dynamometer test run.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and sample probes as required; (2) Observe pre-test procedure, § 86.339; (3) Read and record the... observed torque for the rated and intermediate speeds; (8) Read and record all pre-test data specified in... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Diesel engine dynamometer test run. 86...

  5. 40 CFR 86.341-79 - Diesel engine dynamometer test run.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and sample probes as required; (2) Observe pre-test procedure, § 86.339; (3) Read and record the... observed torque for the rated and intermediate speeds; (8) Read and record all pre-test data specified in... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Diesel engine dynamometer test run. 86...

  6. 40 CFR 86.341-79 - Diesel engine dynamometer test run.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and sample probes as required; (2) Observe pre-test procedure, § 86.339; (3) Read and record the... observed torque for the rated and intermediate speeds; (8) Read and record all pre-test data specified in... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Diesel engine dynamometer test run. 86...

  7. 40 CFR 86.341-79 - Diesel engine dynamometer test run.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and sample probes as required; (2) Observe pre-test procedure, § 86.339; (3) Read and record the... observed torque for the rated and intermediate speeds; (8) Read and record all pre-test data specified in... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Diesel engine dynamometer test run. 86...

  8. Turbine Windage Torque Tests.

    DTIC Science & Technology

    1981-01-01

    chamber, with a 0-60,000 RPM, 300 HP dynamometer, was selected as the test facility. A rotary transformer ( brushless ) torque sensor, using air /oil... brushless ) of 100 and 500 in-lb torque ranges were selected from Lebow Associates, Inc. of Troy, Michigan. Special air / oil mist lubrication for the...period August 1979 - October 1980 I Approved for public release; distribution unlimited. _ DTIC AERO PROPULSION LABORATORY AIR FORCE WRIGHT AERONAUTICAL

  9. 40 CFR 1065.510 - Engine mapping.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the warm-up until the engine coolant, block, or head absolute temperature is within ± 2% of its mean... demand to minimum, use the dynamometer or other loading device to target a torque of zero on the engine's...-speed governor, operate the engine at warm idle speed and zero torque on the engine's primary output...

  10. Properties of Isokinetic Fatigue at Various Movement Speeds in Adult Males.

    ERIC Educational Resources Information Center

    Clarke, David H.; Manning, James M.

    1985-01-01

    Eighteen male subjects, aged 20 to 28 years, engaged in three fatigue bouts using an isokinetic dynamometer to measure knee extension contractions. Peak torque varied inversely with movement speed, and the pattern of decrement was independent of speed. Time to peak torque did not change significantly across trials in isokinetic fatigue. (Author/MT)

  11. 40 CFR 91.404 - Test procedure overview.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... conducted on an engine dynamometer or equivalent load and speed measurement device. The exhaust gases... with an exponential relationship between torque and speed which span the typical operating range of...

  12. 40 CFR 1066.255 - Parasitic loss verification.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... following the dynamometer manufacturer's specifications to establish a parasitic loss curve, taking data at.... Parasitic loss forces may never be negative. Note that the torque transducers must be zeroed and spanned...

  13. 40 CFR 1066.255 - Parasitic loss verification.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... following the dynamometer manufacturer's specifications to establish a parasitic loss curve, taking data at.... Parasitic loss forces may never be negative. Note that the torque transducers must be zeroed and spanned...

  14. 40 CFR 91.404 - Test procedure overview.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... to be conducted on an engine dynamometer or equivalent load and speed measurement device. The exhaust... four power modes with an exponential relationship between torque and speed which span the typical...

  15. 40 CFR 91.404 - Test procedure overview.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... to be conducted on an engine dynamometer or equivalent load and speed measurement device. The exhaust... four power modes with an exponential relationship between torque and speed which span the typical...

  16. Forearm Torque and Lifting Strength: Normative Data.

    PubMed

    Axelsson, Peter; Fredrikson, Per; Nilsson, Anders; Andersson, Jonny K; Kärrholm, Johan

    2018-02-10

    To establish reference values for new methods designed to quantitatively measure forearm torque and lifting strength and to compare these values with grip strength. A total of 499 volunteers, 262 males and 237 females, aged 15 to 85 (mean, 44) years, were tested for lifting strength and forearm torque with the Kern and Baseline dynamometers. These individuals were also tested for grip strength with a Jamar dynamometer. Standardized procedures were used and information about sex, height, weight, hand dominance, and whether their work involved high or low manual strain was collected. Men had approximately 70% higher forearm torque and lifting strength compared with females. Male subjects aged 26 to 35 years and female subjects aged 36 to 45 years showed highest strength values. In patients with dominant right side, 61% to 78% had a higher or equal strength on this side in the different tests performed. In patients with dominant left side, the corresponding proportions varied between 41% and 65%. There was a high correlation between grip strength and forearm torque and lifting strength. Sex, body height, body weight, and age showed a significant correlation to the strength measurements. In a multiple regression model sex, age (entered as linear and squared) could explain 51% to 63% of the total variances of forearm torque strength and 30% to 36% of lifting strength. Reference values for lifting strength and forearm torque to be used in clinical practice were acquired. Grip strength has a high correlation to forearm torque and lifting strength. Sex, age, and height can be used to predict forearm torque and lifting strength. Prediction equations using these variables were generated. Normative data of forearm torque and lifting strength might improve the quality of assessment of wrist and forearm disorders as well as their treatments. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. A ground-based comparison of the Muscle Atrophy Research and Exercise System (MARES) and a commercially available isokinetic dynamometer

    NASA Astrophysics Data System (ADS)

    English, Kirk L.; Hackney, Kyle J.; De Witt, John K.; Ploutz-Snyder, Robert J.; Goetchius, Elizabeth L.; Ploutz-Snyder, Lori L.

    2013-11-01

    IntroductionInternational Space Station (ISS) crewmembers perform muscle strength and endurance testing pre- and postflight to assess the physiologic adaptations associated with long-duration exposure to microgravity. However, a reliable and standardized method to document strength changes in-flight has not been established. To address this issue, a proprietary dynamometer, the Muscle Atrophy Research and Exercise System (MARES) has been developed and flown aboard the ISS. The aims of this ground-based investigation were to: (1) evaluate the test-retest reliability of MARES and (2) determine its agreement with a commercially available isokinetic dynamometer previously used for pre- and postflight medical testing. MethodsSix males (179.5±4.7 cm; 82.0±8.7 kg; 31.3±4.0 yr) and four females (163.2±7.3 cm; 63.2±1.9 kg; 32.3±6.8 yr) completed two testing sessions on a HUMAC NORM isokinetic dynamometer (NORM) and two sessions on MARES using a randomized, counterbalanced, cross-over design. Peak torque values at 60° and 180° s-1 were calculated from five maximal repetitions of knee extension (KE) and knee flexion (KF) for each session. Total work at 180° s-1 was determined from the area under the torque versus displacement curve during 20 maximal repetitions of KE and KF. ResultsIntraclass correlation coefficients were relatively high for both devices (0.90-0.99). Only one dependent measure, KE peak torque at 60° s-1 exhibited good concordance between devices (ρ=0.92) and a small average difference (0.9±17.3 N m). ConclusionMARES demonstrated acceptable test-retest reliability and thus should serve as a good tool to monitor in-flight strength changes. However, due to poor agreement with NORM, it is not advisable to compare absolute values obtained on these devices.

  18. Design verification tests for an axial gap permanent magnet compressor motor

    NASA Astrophysics Data System (ADS)

    Hawsey, R. A.; Bailey, J. M.

    1987-07-01

    A 30-hp, direct-drive, permanent magnet motor (PMM) has been constructed. The motor is to operate at 15,000 rpm and is designed to drive a Worthington compressor at the US DOE-owned gaseous diffusion plants. The PMM prevents traditional dynamometer testing, including locked rotor current, voltage, and torque measurements. A test plan is presented for data acquisition on the dynamometer test stand in order to calculate the equivalent circuit for the motor. A description of the hardware required for these measurements is included in the plan.

  19. Calculation of Resistive Loads for Elastic Resistive Exercises.

    PubMed

    Picha, Kelsey; Uhl, Tim

    2018-03-14

    What is the correct resistive load to start resistive training with elastic resistance to gain strength? This question is typically answered by the clinician's best estimate and patient's level of discomfort without objective evidence. To determine the average level of resistance to initiate a strengthening routine with elastic resistance following isometric strength testing. Cohort. Clinical. 34 subjects (31 ± 13 y, 73 ± 17 kg, 170 ± 12 cm). The force produced was measured in Newtons (N) with an isometric dynamometer. The force distance was the distance from center of joint to location of force applied was measured in meters to calculate torque that was called "Test Torque" for the purposes of this report. This torque data was converted to "Exercise Load" in pounds based on the location where the resistance was applied, specifically the distance away from the center of rotation of the exercising limb. The average amount of exercise load as percentage of initial Test Torque for each individual for each exercise was recorded to determine what the average level of resistance that could be used for elastic resistance strengthening program. The percentage of initial test torque calculated for the exercise was recorded for each exercise and torque produced was normalized to body weight. The average percentage of maximal isometric force that was used to initiate exercises was 30 ± 7% of test torque. This provides clinicians with an objective target load to start elastic resistance training. Individual variations will occur but utilization of a load cell during elastic resistance provides objective documentation of exercise progression.

  20. Hamstring Stiffness Returns More Rapidly After Static Stretching Than Range of Motion, Stretch Tolerance, and Isometric Peak Torque.

    PubMed

    Hatano, Genki; Suzuki, Shigeyuki; Matsuo, Shingo; Kataura, Satoshi; Yokoi, Kazuaki; Fukaya, Taizan; Fujiwara, Mitsuhiro; Asai, Yuji; Iwata, Masahiro

    2017-12-18

    Hamstring injuries are common, and lack of hamstring flexibility may predispose to injury. Static stretching increases range of motion (ROM) but also results in reduced muscle strength after stretching. The effects of stretching on the hamstring muscles and the duration of these effects remain unclear. To determine the effects of static stretching on the hamstrings and the duration of these effects. Randomized crossover study. University laboratory. Twenty-four healthy volunteers. We measured the torque-angle relationship (ROM, passive torque (PT) at the onset of pain, and passive stiffness) and isometric muscle force using an isokinetic dynamometer. After a 60-minute rest, the ROM of the dynamometer was set at maximum tolerable intensity; this position was maintained for 300 seconds while static passive torque (SPT) was measured continuously. We remeasured the torque-angle relationship and isometric muscle force after rest periods of 10, 20, and 30 minutes. Change in SPT during stretching; changes in ROM, PT at the onset of pain, passive stiffness, and isometric muscle force before stretching compared with 10, 20, and 30 minutes after stretching. SPT decreased significantly during stretching. Passive stiffness decreased significantly 10 and 20 minutes after stretching, but there was no significant pre- vs. post-stretching difference after 30 minutes. PT at the onset of pain and ROM increased significantly after stretching at all rest intervals, while isometric muscle force decreased significantly after all rest intervals. The effect of static stretching on passive stiffness of the hamstrings was not maintained as long as the changes in ROM, stretch tolerance, and isometric muscle force. Therefore, frequent stretching is necessary to improve the viscoelasticity of the muscle-tendon unit. Muscle force was decreased for 30 minutes after stretching; this should be considered prior to activities requiring maximal muscle strength.

  1. Intramuscular pressure and torque during isometric, concentric and eccentric muscular activity

    NASA Technical Reports Server (NTRS)

    Styf, J.; Ballard, R.; Aratow, M.; Crenshaw, A.; Watenpaugh, D.; Hargens, A. R.

    1995-01-01

    Intramuscular pressures, electromyography (EMG) and torque generation during isometric, concentric and eccentric maximal isokinetic muscle activity were recorded in 10 healthy volunteers. Pressure and EMG activity were continuously and simultaneously measured side by side in the tibialis anterior and soleus muscles. Ankle joint torque and position were monitored continuously by an isokinetic dynamometer during plantar flexion and dorsiflexion of the foot. The increased force generation during eccentric muscular activity, compared with other muscular activity, was not accompanied by higher intramuscular pressure. Thus, this study demonstrated that eccentric muscular activity generated higher torque values for each increment of intramuscular pressure. Intramuscular pressures during antagonistic co-activation were significantly higher in the tibilis anterior muscle (42-46% of maximal agonistic activity) compared with the soleus muscle (12-29% of maximal agonistic activity) and was largely due to active recruitment of muscle fibers. In summary, eccentric muscular activity creates higher torque values with no additional increase of the intramuscular pressure compared with concentric and isometric muscular activity.

  2. Recovery of pectoralis major and triceps brachii after bench press exercise.

    PubMed

    Ferreira, Diogo V; Gentil, Paulo; Soares, Saulo Rodrigo Sampaio; Bottaro, Martim

    2017-11-01

    The present study evaluated and compared the recovery of pectoralis major (PM) and triceps brachii (TB) muscles of trained men after bench press exercise. Eighteen volunteers performed eight sets of bench press exercise to momentary muscle failure and were evaluated for TB and PM peak torque and total work on an isokinetic dynamometer. PM peak torque and total work remained lower than baseline for 72 and 96 h, respectively. TB peak torque was only different from baseline immediately post training, while total work was significantly lower than baseline immediately and 48 h after training. Normalized peak torque values were only different between TB and PM at 48 h after training. Considering the small and nonsignificant difference between the recovery of TB and PM muscles, the results suggest that bench press exercise may promote a similar stress on these muscles. Muscle Nerve 56: 963-967, 2017. © 2016 Wiley Periodicals, Inc.

  3. Muscle Fatigue during Intermittent Exercise in Individuals with Mental Retardation

    ERIC Educational Resources Information Center

    Zafeiridis, Andreas; Giagazoglou, Paraskevi; Dipla, Konstantina; Salonikidis, Konstantinos; Karra, Chrisanthi; Kellis, Eleftherios

    2010-01-01

    This study examined fatigue profile during intermittent exercise in 10 men with mild to moderate mental retardation (MR) and 10 men without mental retardation (C). They performed 4 x 30 s maximal knee extensions and flexions with 1-min rest on an isokinetic dynamometer. Peak torque of flexors (PTFL) and extensors (PTEX), total work (TW), and…

  4. Muscle torque of healthy individuals and individuals with spastic hemiparesis after passive static streching.

    PubMed

    Tatsukawa DE Freitas, Sérgio Takeshi; DE Carvalho Abreu, Elizângela Márcia; Dos Reis, Mariane Cecilia; DE Souza Cunha, Bruna; Souza Moreira Prianti, Tamires; Pupio Silva Lima, Fernanda; Oliveira Lima, Mário

    2016-01-01

    Spasticity is one of the main causes of contracture, muscle weakness and subsequent functional incapacity. The passive static stretching can be included as having the purpose of increasing musculoskeletal flexibility, however, it also can influence the muscle torque. The objective is to verify the immediate effect of passive static stretching in the muscle strength of healthy and those who present spastic hemiparesis. There were assessed 20 subjects, 10 spastic hemiparetic (EG) and 10 healthy individuals (CG), including both sexes, aged between 22 and 78 years. The torque of extensor muscles of the knee was analyzed using isokinetic dynamometer. Results have shown that EG has less muscle torque compared to CG ( p < 0.01). In addition, EG presented a decrease in significance of muscle torque after stretching ( p < 0.05), however, it has not shown significant alteration in muscle torque of CG after performing the program that was prescribed. Immediately after the passive stretch, a significant torque decrease can be seen in hypertonic muscle; it is believed that this reduction may be associated with the physiological overlap between actin and myosin filaments and so preventing the muscle to develop a maximum contraction.

  5. A Ground-Based Comparison of the Muscle Atrophy Research and Exercise System (MARES) and a Standard Isokinetic Dynamometer

    NASA Technical Reports Server (NTRS)

    Hackney, K. J.; English, K. L.; Redd, E.; DeWitt, J. K.; Ploutz-Snyder, R.; Ploutz-Snyder, L. L.

    2010-01-01

    PURPOSE: 1) To compare the test-to-test reliability of Muscle Atrophy Research and Exercise System (MARES) with a standard laboratory isokinetic dynamometer (ISOK DYN) and; 2) to determine if measures of peak torque and total work differ between devices. METHODS: Ten subjects (6M, 4F) completed two trials on both MARES and an ISOK DYN in a counterbalanced order. Peak torque values at 60 deg & 180 deg / s were obtained from five maximal repetitions of knee extension (KE) and knee flexion (KF). Total work at 180 deg / s was determined from the area under the torque vs. displacement curve during twenty maximal repetitions of KE and KF. Reliability of measures within devices was interpreted from the intraclass correlation coefficient (ICC) and compared between devices using the ratio of the within-device standard deviations. Indicators of agreement for the two devices were evaluated from: 1) a calculation of concordance (rho) and; 2) the correlation between the mean of measures versus the delta difference between measures (m u vs delta). RESULTS: For all outcome measures ICCs were high for both the ISOK DYN (0.95-0.99) and MARES (0.90-0.99). However, ratios of the within-device standard deviation were 1.3 to 4.3 times higher on MARES. On average, a wide range (3.3 to 1054 Nm) of differences existed between the values obtained. Only KE peak torque measured at 60 deg & 180 deg / s showed similarities between devices (rho = 0.91 & 0.87; Pearson's r for m u vs delta = -0.22 & -0.37, respectively). CONCLUSION: Although MARES was designed for use in microgravity it was quite reliable during ground-based testing. However, MARES was consistently more variable than an ISOK DYN. Future longitudinal studies evaluating a change in isokinetic peak torque or total work should be limited within one device.

  6. Speed, not magnitude, of knee extensor torque production is associated with self-reported knee function early after anterior cruciate ligament reconstruction.

    PubMed

    Hsieh, Chao-Jung; Indelicato, Peter A; Moser, Michael W; Vandenborne, Krista; Chmielewski, Terese L

    2015-11-01

    To examine the magnitude and speed of knee extensor torque production at the initiation of advanced anterior cruciate ligament (ACL) reconstruction rehabilitation and the associations with self-reported knee function. Twenty-eight subjects who were 12 weeks post-ACL reconstruction and 28 age- and sex-matched physically active controls participated in this study. Knee extensor torque was assessed bilaterally with an isokinetic dynamometer at 60°/s. The variables of interest were peak torque, average rate of torque development, time to peak torque and quadriceps symmetry index. Knee function was assessed with the International Knee Documentation Committee Subjective Knee Form (IKDC-SKF). Peak torque and average rate of torque development were lower on the surgical side compared to the non-surgical side and controls. Quadriceps symmetry index was lower in subjects with ACL reconstruction compared to controls. On the surgical side, average rate of torque development was positively correlated with IKDC-SKF score (r = 0.379) while time to peak torque was negatively correlated with IKDC-SKF score (r = -0.407). At the initiation of advanced ACL reconstruction rehabilitation, the surgical side displayed deficits in peak torque and average rate of torque development. A higher rate of torque development and shorter time to peak torque were associated with better self-reported knee function. The results suggest that the rate of torque development should be addressed during advanced ACL reconstruction rehabilitation and faster knee extensor torque generation may lead to better knee function. III.

  7. Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study

    PubMed Central

    Kim, Won Kuel; Seo, Kyung Mook; Kang, Si Hyun

    2014-01-01

    Objective To determine the reliability and validity of hand-held dynamometer (HHD) depending on its fixation in measuring isometric knee extensor strength by comparing the results with an isokinetic dynamometer. Methods Twenty-seven healthy female volunteers participated in this study. The subjects were tested in seated and supine position using three measurement methods: isometric knee extension by isokinetic dynamometer, non-fixed HHD, and fixed HHD. During the measurement, the knee joints of subjects were fixed at a 35° angle from the extended position. The fixed HHD measurement was conducted with the HHD fixed to distal tibia with a Velcro strap; non-fixed HHD was performed with a hand-held method without Velcro fixation. All the measurements were repeated three times and among them, the maximum values of peak torque were used for the analysis. Results The data from the fixed HHD method showed higher validity than the non-fixed method compared with the results of the isokinetic dynamometer. Pearson correlation coefficients (r) between fixed HHD and isokinetic dynamometer method were statistically significant (supine-right: r=0.806, p<0.05; seating-right: r=0.473, p<0.05; supine-left: r=0.524, p<0.05), whereas Pearson correlation coefficients between non-fixed dynamometer and isokinetic dynamometer methods were not statistically significant, except for the result of the supine position of the left leg (r=0.384, p<0.05). Both fixed and non-fixed HHD methods showed excellent inter-rater reliability. However, the fixed HHD method showed a higher reliability than the non-fixed HHD method by considering the intraclass correlation coefficient (fixed HHD, 0.952-0.984; non-fixed HHD, 0.940-0.963). Conclusion Fixation of HHD during measurement in the supine position increases the reliability and validity in measuring the quadriceps strength. PMID:24639931

  8. Do peak torque angles of muscles change following anterior cruciate ligament reconstruction using hamstring or patellar tendon graft?

    PubMed

    Yosmaoğlu, Hayri Baran; Baltacı, Gül; Sönmezer, Emel; Özer, Hamza; Doğan, Deha

    2017-12-01

    This study aims to compare the effects of anterior cruciate ligament (ACL) reconstruction using autogenous hamstring or patellar tendon graft on the peak torque angle. The study included 132 patients (103 males, 29 females; mean age 29±9 year) who were performed ACL reconstruction with autogenous hamstring or patellar tendon graft. The peak torque angles in the quadriceps and hamstring muscles were recorded using an isokinetic dynamometer. Angle of peak knee flexion torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the hamstring tendon group. Angle of peak knee extension torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the patellar tendon group. There were no statistically significant differences in the flexion and extension peak torque angles between the operated and nonoperated knees at 60°/second in both groups. The angle of peak torque at relatively high angular velocities is affected after ACL reconstruction in patients with hamstring or patellar tendon grafts. The graft donor site directly influences this parameter. This finding may be important for clinicians in terms of preventing re-injury.

  9. A High Performance Torque Sensor for Milling Based on a Piezoresistive MEMS Strain Gauge

    PubMed Central

    Qin, Yafei; Zhao, Yulong; Li, Yingxue; Zhao, You; Wang, Peng

    2016-01-01

    In high speed and high precision machining applications, it is important to monitor the machining process in order to ensure high product quality. For this purpose, it is essential to develop a dynamometer with high sensitivity and high natural frequency which is suited to these conditions. This paper describes the design, calibration and performance of a milling torque sensor based on piezoresistive MEMS strain. A detailed design study is carried out to optimize the two mutually-contradictory indicators sensitivity and natural frequency. The developed torque sensor principally consists of a thin-walled cylinder, and a piezoresistive MEMS strain gauge bonded on the surface of the sensing element where the shear strain is maximum. The strain gauge includes eight piezoresistances and four are connected in a full Wheatstone circuit bridge, which is used to measure the applied torque force during machining procedures. Experimental static calibration results show that the sensitivity of torque sensor has been improved to 0.13 mv/Nm. A modal impact test indicates that the natural frequency of torque sensor reaches 1216 Hz, which is suitable for high speed machining processes. The dynamic test results indicate that the developed torque sensor is stable and practical for monitoring the milling process. PMID:27070620

  10. Development and performance characterization of an electric ground vehicle with independently actuated in-wheel motors

    NASA Astrophysics Data System (ADS)

    Wang, Rongrong; Chen, Yan; Feng, Daiwei; Huang, Xiaoyu; Wang, Junmin

    This paper presents the development and experimental characterizations of a prototyping pure electric ground vehicle, which is equipped with four independently actuated in-wheel motors (FIAIWM) and is powered by a 72 V 200 Ah LiFeYPO 4 battery pack. Such an electric ground vehicle (EGV) employs four in-wheel (or hub) motors to independently drive/brake the four wheels and is one of the promising vehicle architectures primarily due to its actuation flexibility, energy efficiency, and performance potentials. Experimental data obtained from the EGV chassis dynamometer tests were employed to generate the in-wheel motor torque response and power efficiency maps in both driving and regenerative braking modes. A torque distribution method is proposed to show the potentials of optimizing the FIAIWM EGV operational energy efficiency by utilizing the actuation flexibility and the characterized in-wheel motor efficiency and torque response.

  11. Transistorized PWM inverter-induction motor drive system

    NASA Technical Reports Server (NTRS)

    Peak, S. C.; Plunkett, A. B.

    1982-01-01

    This paper describes the development of a transistorized PWM inverter-induction motor traction drive system. A vehicle performance analysis was performed to establish the vehicle tractive effort-speed requirements. These requirements were then converted into a set of inverter and motor specifications. The inverter was a transistorized three-phase bridge using General Electric power Darlington transistors. The description of the design and development of this inverter is the principal object of this paper. The high-speed induction motor is a design which is optimized for use with an inverter power source. The primary feedback control is a torque angle control with voltage and torque outer loop controls. A current-controlled PWM technique is used to control the motor voltage. The drive has a constant torque output with PWM operation to base motor speed and a constant horsepower output with square wave operation to maximum speed. The drive system was dynamometer tested and the results are presented.

  12. Reference values of hip abductor torque among youth athletes: Influence of age, sex and sports.

    PubMed

    Bittencourt, Natália Franco Netto; Santos, Thiago Ribeiro Teles; Gonçalves, Gabriela Gomes Pavan; Coelho, Amanda Priscila; Gomes, Bárbara Gonçalves Braz de Magalhães; Mendonça, Luciana De Michelis; Fonseca, Sérgio Teixeira

    2016-09-01

    (1) To determine the reference values of hip abductor torque in youth athletes; (2) To investigate the influence of sex, age and sports on hip abductors torque. Cross-sectional. Sports clubs. 301 volleyball, basketball and futsal athletes between 10 and 19 years of age. Mean value of three maximal isometric hip abductor torques, evaluated using a hand-held dynamometer. The mean values of maximal isometric hip abductor torque ranged from 1.03 to 1.50 Nm/kg. The dominant hip abductor torque values were greater in 15-19 years old (1.41 ± 0.27 Nm/kg) than in 10-14 years old (1.12 ± 0.31 Nm/kg). In addition, the hip abductor torque values were smaller in basketball players (1.15 ± 0.31 Nm/kg) than futsal (1.34 ± 0.37 Nm/kg) and volleyball players (1.28 ± 0.25 Nm/kg). The comparison of hip abductor torque between futsal and volleyball players revealed no difference. The hip abductor torque values were greater in male volleyball athletes (1.28 ± 0.25 Nm/kg) than female volleyball athletes (1.13 ± 0.22 Nm/kg). This study established reference values for maximal isometric hip abductor torque in youth volleyball, basketball and futsal athletes. In addition, the results demonstrated that sex, age and sports influenced hip abductor torque. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Estimation of Electrically-Evoked Knee Torque from Mechanomyography Using Support Vector Regression.

    PubMed

    Ibitoye, Morufu Olusola; Hamzaid, Nur Azah; Abdul Wahab, Ahmad Khairi; Hasnan, Nazirah; Olatunji, Sunday Olusanya; Davis, Glen M

    2016-07-19

    The difficulty of real-time muscle force or joint torque estimation during neuromuscular electrical stimulation (NMES) in physical therapy and exercise science has motivated recent research interest in torque estimation from other muscle characteristics. This study investigated the accuracy of a computational intelligence technique for estimating NMES-evoked knee extension torque based on the Mechanomyographic signals (MMG) of contracting muscles that were recorded from eight healthy males. Simulation of the knee torque was modelled via Support Vector Regression (SVR) due to its good generalization ability in related fields. Inputs to the proposed model were MMG amplitude characteristics, the level of electrical stimulation or contraction intensity, and knee angle. Gaussian kernel function, as well as its optimal parameters were identified with the best performance measure and were applied as the SVR kernel function to build an effective knee torque estimation model. To train and test the model, the data were partitioned into training (70%) and testing (30%) subsets, respectively. The SVR estimation accuracy, based on the coefficient of determination (R²) between the actual and the estimated torque values was up to 94% and 89% during the training and testing cases, with root mean square errors (RMSE) of 9.48 and 12.95, respectively. The knee torque estimations obtained using SVR modelling agreed well with the experimental data from an isokinetic dynamometer. These findings support the realization of a closed-loop NMES system for functional tasks using MMG as the feedback signal source and an SVR algorithm for joint torque estimation.

  14. 40 CFR 1066.705 - Symbols, abbreviations, acronyms, and units of measure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... series n total number of pulses in a series R dynamometer roll revolutions revolutions per minute rpm 2·π... torque (moment of force) newton meter N·m m2·kg·s−2 t time second s s Δt time interval, period, 1... atmospheric b base c coastdown e effective error error exp expected quantity i an individual of a series final...

  15. Reliability and validity of the closed kinetic chain upper extremity stability test.

    PubMed

    Lee, Dong-Rour; Kim, Laurentius Jongsoon

    2015-04-01

    [Purpose] The purpose of this study was to examine the reliability and validity of the Closed Kinetic Chain Upper Extremity Stability (CKCUES) test. [Subjects and Methods] A sample of 40 subjects (20 males, 20 females) with and without pain in the upper limbs was recruited. The subjects were tested twice, three days apart to assess the reliability of the CKCUES test. The CKCUES test was performed four times, and the average was calculated using the data of the last 3 tests. In order to test the validity of the CKCUES test, peak torque of internal/external shoulder rotation was measured using an isokinetic dynamometer, and maximum grip strength was measured using a hand dynamometer, and their Pearson correlation coefficients with the average values of the CKCUES test were calculated. [Results] The reliability of the CKCUES test was very high (ICC=0.97). The correlations between the CKCUES test and maximum grip strength (r=0.78-0.79), and the peak torque of internal/external shoulder rotation (r=0.87-0.94) were high indicating its validity. [Conclusion] The reliability and validity of the CKCUES test were high. The CKCUES test is expected to be used for clinical tests on upper limb stability at low price.

  16. Modelling the maximum voluntary joint torque/angular velocity relationship in human movement.

    PubMed

    Yeadon, Maurice R; King, Mark A; Wilson, Cassie

    2006-01-01

    The force exerted by a muscle is a function of the activation level and the maximum (tetanic) muscle force. In "maximum" voluntary knee extensions muscle activation is lower for eccentric muscle velocities than for concentric velocities. The aim of this study was to model this "differential activation" in order to calculate the maximum voluntary knee extensor torque as a function of knee angular velocity. Torque data were collected on two subjects during maximal eccentric-concentric knee extensions using an isovelocity dynamometer with crank angular velocities ranging from 50 to 450 degrees s(-1). The theoretical tetanic torque/angular velocity relationship was modelled using a four parameter function comprising two rectangular hyperbolas while the activation/angular velocity relationship was modelled using a three parameter function that rose from submaximal activation for eccentric velocities to full activation for high concentric velocities. The product of these two functions gave a seven parameter function which was fitted to the joint torque/angular velocity data, giving unbiased root mean square differences of 1.9% and 3.3% of the maximum torques achieved. Differential activation accounts for the non-hyperbolic behaviour of the torque/angular velocity data for low concentric velocities. The maximum voluntary knee extensor torque that can be exerted may be modelled accurately as the product of functions defining the maximum torque and the maximum voluntary activation level. Failure to include differential activation considerations when modelling maximal movements will lead to errors in the estimation of joint torque in the eccentric phase and low velocity concentric phase.

  17. Bilateral pedaling asymmetry during a simulated 40-km cycling time-trial.

    PubMed

    Carpes, F P; Rossato, M; Faria, I E; Bolli Mota, C

    2007-03-01

    This study investigated the pedaling asymmetry during a 40-km cycling time-trial (TT). Six sub-elite competitive male cyclists pedaled a SRM Training Systems cycle ergometer throughout a simulated 40-km TT. A SRM scientific crank dynamometer was used to measure the bilateral crank torque (N.m) and pedaling cadence (rpm). All data were analyzed into 4 stages with equal length obtained according to total time. Comparisons between each stage of the 40-km TT were made by an analysis of variance (ANOVA). Dominant (DO) and non-dominant (ND) crank peak torque asymmetry was determined by the equation: asymmetry index (AI%)=[(DO-ND)/DO] 100. Pearson correlation analysis was performed to verify the relationship between exercise intensity, mean and crank peak torque. The crank peak torque was significantly (P<0.05) greater in the 4th stage compared with other stages. During the stages 2 and 3, was observed the AI% of 13.51% and 17.28%, respectively. Exercise intensity (%VO(2max)) was greater for stage 4 (P<0.05) and was highly correlated with mean and crank peak torque (r=0.97 and r=0.92, respectively) for each stage. The DO limb was always responsible for the larger crank peak torque. It was concluded that pedaling asymmetry is present during a simulated 40-km TT and an increase on crank torque output and exercise intensity elicits a reduction in pedaling asymmetry.

  18. Provocative mechanical tests of the peripheral nervous system affect the joint torque-angle during passive knee motion.

    PubMed

    Andrade, R J; Freitas, S R; Vaz, J R; Bruno, P M; Pezarat-Correia, P

    2015-06-01

    This study aimed to determine the influence of the head, upper trunk, and foot position on the passive knee extension (PKE) torque-angle response. PKE tests were performed in 10 healthy subjects using an isokinetic dynamometer at 2°/s. Subjects lay in the supine position with their hips flexed to 90°. The knee angle, passive torque, surface electromyography (EMG) of the semitendinosus and quadriceps vastus medialis, and stretch discomfort were recorded in six body positions during PKE. The different maximal active positions of the cervical spine (neutral; flexion; extension), thoracic spine (neutral; flexion), and ankle (neutral; dorsiflexion) were passively combined for the tests. Visual analog scale scores and EMG were unaffected by body segment positioning. An effect of the ankle joint was verified on the peak torque and knee maximum angle when the ankle was in the dorsiflexion position (P < 0.05). Upper trunk positioning had an effect on the knee submaximal torque (P < 0.05), observed as an increase in the knee passive submaximal torque when the cervical and thoracic spines were flexed (P < 0.05). In conclusion, other apparently mechanical unrelated body segments influence torque-angle response since different positions of head, upper trunk, and foot induce dissimilar knee mechanical responses during passive extension. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Analysis of isokinetic muscle strength for sports physiotherapy research in Korean ssireum athletes

    PubMed Central

    Noh, Ji-Woong; Park, Byoung-Sun; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Park, Jaehong; Kim, Junghwan

    2015-01-01

    [Purpose] The purpose of the present study was to elucidate the muscle conditions such as the isokinetic muscle of Korean ssireum athletes. [Subjects and Methods] This study enrolled 25 elite ssireum athletes. We measured body composition and peak torque at an angular speed at 60°/s using an isokinetic muscle strength dynamometer. [Results] The lean body mass of the left upper limb was significantly higher than that of the right upper limb. However, the lean body mass of the left lower limb was significantly lower than that of the right lower limb. The peak torque for left elbow flexion was significantly higher than that for right elbow flexion. Conversely, the peak torque for left elbow extension was significantly lower than that for right elbow extension. Furthermore, the peak torque for the left knee was significantly lower than that for the right knee for both flexion and extension. [Conclusion] The data from this study elucidate in part the muscle conditions of Korean ssireum athletes, which can be used to establish a reference for the scientific study of sports physiotherapy. PMID:26644679

  20. Analysis of isokinetic muscle strength for sports physiotherapy research in Korean ssireum athletes.

    PubMed

    Noh, Ji-Woong; Park, Byoung-Sun; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Park, Jaehong; Kim, Junghwan

    2015-10-01

    [Purpose] The purpose of the present study was to elucidate the muscle conditions such as the isokinetic muscle of Korean ssireum athletes. [Subjects and Methods] This study enrolled 25 elite ssireum athletes. We measured body composition and peak torque at an angular speed at 60°/s using an isokinetic muscle strength dynamometer. [Results] The lean body mass of the left upper limb was significantly higher than that of the right upper limb. However, the lean body mass of the left lower limb was significantly lower than that of the right lower limb. The peak torque for left elbow flexion was significantly higher than that for right elbow flexion. Conversely, the peak torque for left elbow extension was significantly lower than that for right elbow extension. Furthermore, the peak torque for the left knee was significantly lower than that for the right knee for both flexion and extension. [Conclusion] The data from this study elucidate in part the muscle conditions of Korean ssireum athletes, which can be used to establish a reference for the scientific study of sports physiotherapy.

  1. Comparison of different passive knee extension torque-angle assessments.

    PubMed

    Freitas, Sandro R; Vaz, João R; Bruno, Paula M; Valamatos, Maria J; Mil-Homens, Pedro

    2013-11-01

    Previous studies have used isokinetic dynamometry to assess joint torques and angles during passive extension of the knee, often without reporting upon methodological errors and reliability outcomes. In addition, the reliability of the techniques used to measure passive knee extension torque-angle and the extent to which reliability may be affected by the position of the subjects is also unclear. Therefore, we conducted an analysis of the intra- and inter-session reliability of two methods of assessing passive knee extension: (A) a 2D kinematic analysis coupled to a custom-made device that enabled the direct measurement of resistance to stretch and (B) an isokinetic dynamometer used in two testing positions (with the non-tested thigh either flexed at 45° or in the neutral position). The intra-class correlation coefficients (ICCs) of torque, the slope of the torque-angle curve, and the parameters of the mathematical model that were fit to the torque-angle data for the above conditions were measured in sixteen healthy male subjects (age: 21.4 ± 2.1 yr; BMI: 22.6 ± 3.3 kg m(-2); tibial length: 37.4 ± 3.4 cm). The results found were: (1) methods A and B led to distinctly different torque-angle responses; (2) passive torque-angle relationship and stretch tolerance were influenced by the position of the non-tested thigh; and (3) ICCs obtained for torque were higher than for the slope and for the mathematical parameters that were fit to the torque-angle curve. In conclusion, the measurement method that is used and the positioning of subjects can influence the passive knee extension torque-angle outcome.

  2. Dynamic and Transient Performance of Turbofan/Turboshaft Convertible Engine With Variable Inlet Guide Vanes

    NASA Technical Reports Server (NTRS)

    McArdle, Jack G.; Barth, Richard L.; Wenzel, Leon M.; Biesiadny, Thomas J.

    1996-01-01

    A convertible engine called the CEST TF34, using the variable inlet guide vane method of power change, was tested on an outdoor stand at the NASA Lewis Research Center with a waterbrake dynamometer for the shaft load. A new digital electronic system, in conjunction with a modified standard TF34 hydromechanical fuel control, kept engine operation stable and safely within limits. All planned testing was completed successfully. Steady-state performance and acoustic characteristics were reported previously and are referenced. This report presents results of transient and dynamic tests. The transient tests measured engine response to several rapid changes in thrust and torque commands at constant fan (shaft) speed. Limited results from dynamic tests using the pseudorandom binary noise technique are also presented. Performance of the waterbrake dynamometer is discussed in an appendix.

  3. Intrarater Reliability of Muscle Strength and Hamstring to Quadriceps Strength Imbalance Ratios During Concentric, Isometric, and Eccentric Maximal Voluntary Contractions Using the Isoforce Dynamometer.

    PubMed

    Mau-Moeller, Anett; Gube, Martin; Felser, Sabine; Feldhege, Frank; Weippert, Matthias; Husmann, Florian; Tischer, Thomas; Bader, Rainer; Bruhn, Sven; Behrens, Martin

    2017-08-17

    To determine intrasession and intersession reliability of strength measurements and hamstrings to quadriceps strength imbalance ratios (H/Q ratios) using the new isoforce dynamometer. Repeated measures. Exercise science laboratory. Thirty healthy subjects (15 females, 15 males, 27.8 years). Coefficient of variation (CV) and intraclass correlation coefficients (ICC) were calculated for (1) strength parameters, that is peak torque, mean work, and mean power for concentric and eccentric maximal voluntary contractions; isometric maximal voluntary torque (IMVT); rate of torque development (RTD), and (2) H/Q ratios, that is conventional concentric, eccentric, and isometric H/Q ratios (Hcon/Qcon at 60 deg/s, 120 deg/s, and 180 deg/s, Hecc/Qecc at -60 deg/s and Hiso/Qiso) and functional eccentric antagonist to concentric agonist H/Q ratios (Hecc/Qcon and Hcon/Qecc). High reliability: CV <10%, ICC >0.90; moderate reliability: CV between 10% and 20%, ICC between 0.80 and 0.90; low reliability: CV >20%, ICC <0.80. (1) Strength parameters: (a) high intrasession reliability for concentric, eccentric, and isometric measurements, (b) moderate-to-high intersession reliability for concentric and eccentric measurements and IMVT, and (c) moderate-to-high intrasession reliability but low intersession reliability for RTD. (2) H/Q ratios: (a) moderate-to-high intrasession reliability for conventional ratios, (b) high intrasession reliability for functional ratios, (c) higher intersession reliability for Hcon/Qcon and Hiso/Qiso (moderate to high) than Hecc/Qecc (low to moderate), and (d) higher intersession reliability for conventional H/Q ratios (low to high) than functional H/Q ratios (low to moderate). The results have confirmed the reliability of strength parameters and the most frequently used H/Q ratios.

  4. Effect of eccentric training on the plantar flexor muscle-tendon tissue properties.

    PubMed

    Mahieu, Nele Nathalie; McNair, Peter; Cools, Ann; D'Haen, Caroline; Vandermeulen, Katrien; Witvrouw, Erik

    2008-01-01

    It has been shown that eccentric training can be effective in the rehabilitation of patients with Achilles tendonopathy. The mechanism behind these results is not clear. However, there is evidence that tendons are able to respond to repeated forces by altering their structure and composition, and, thus, their mechanical properties change. In this regard, the objective of the present study was to investigate whether eccentric training affects the mechanical properties of the plantar flexor's muscle-tendon tissue properties. Seventy-four healthy subjects were randomized into two groups: an eccentric training group and a control group. The eccentric training group performed a 6-wk eccentric training program for the calf muscles. Before and after this period, all subjects were evaluated for dorsiflexion range of motion using universal goniometry, passive resistive torque of the plantar flexors, and stiffness of the Achilles tendon. Passive resistive torque was measured during ankle dorsiflexion on an isokinetic dynamometer. Stiffness of the Achilles tendon was assessed using a dynamometer, in combination with ultrasonography. The results of the study reveal that the dorsiflexion range of motion was significantly increased only in the eccentric training group. The eccentric heel drop program also resulted in a significant decrease of the passive resistive torque of the plantar flexors (from 16.423 +/- 0.827 to 12.651 +/- 0.617 N.m). The stiffness of the Achilles tendon did not change significantly as a result of training. These findings provide evidence that an eccentric training program results in changes to some of the mechanical properties of the plantar flexor muscles. These changes were thought to be associated with modifications to structure rather than to stretch tolerance.

  5. Hamstrings strength imbalance in professional football (soccer) players in Australia.

    PubMed

    Ardern, Clare L; Pizzari, Tania; Wollin, Martin R; Webster, Kate E

    2015-04-01

    The aim of this study was to describe the isokinetic thigh muscle strength profile of professional male football players in Australia. Concentric (60° and 240°·s(-1)) and eccentric (30° and 120°·s(-1)) hamstrings and quadriceps isokinetic strength was measured with a HUMAC NORM dynamometer. The primary variables were bilateral concentric and eccentric hamstring and quadriceps peak torque ratios, concentric hamstring-quadriceps peak torque ratios, and mixed ratios (eccentric hamstring 30°·s(-1) ÷ concentric quadriceps 240°·s(-1)). Hamstring strength imbalance was defined as deficits in any 2 of: bilateral concentric hamstring peak torque ratio <0.86, bilateral eccentric hamstring peak torque ratio <0.86, concentric hamstring-quadriceps ratio <0.47, and mixed ratio <0.80. Fifty-five strength tests involving 42 players were conducted. Ten players (24%) were identified as having hamstring strength imbalance. Athletes with strength imbalance had significantly reduced concentric and eccentric bilateral hamstring peak torque ratios at all angular velocities tested; and reduced eccentric quadriceps peak torque (30°·s(-1)) in their stance leg, compared with those without strength imbalance. Approximately, 1 in 4 players had preseason hamstring strength imbalance; and all strength deficits were observed in the stance leg. Concentric and eccentric hamstrings strength imbalance may impact in-season football performance and could have implications for the future risk of injury.

  6. Intramuscular pressure and electromyography as indexes of force during isokinetic exercise

    NASA Technical Reports Server (NTRS)

    Aratow, M.; Ballard, R. E.; Grenshaw, A. G.; Styf, J.; Watenpaugh, D. E.; Kahan, N. J.; Hargens, A. R.

    1993-01-01

    A direct method for measuring force production of specific muscles during dynamic exercise is presently unavailable. Previous studies indicate that both intramuscular pressure (IMP) and electromyography (EMG) correlate linearly with muscle contraction force during isometric exercise. The objective of this study was to compare IMP and EMG as linear assessors of muscle contraction force during dynamic exercise. IMP and surface EMG activity were recorded during concentric and eccentric isokinetic plantarflexion and dorsiflexion of the ankle joint from the tibialis anterior (TA) and soleus (SOL) muscles of nine male volunteers. Ankle torque was measured using a dynamometer, and IMP was measured via catheterization. IMP exhibited better linear correlation than EMG with ankle joint torque during concentric contractions of the SOL and the TA, as well as during eccentric contractions. IMP provides a better index of muscle contraction force than EMG during concentric and eccentric exercise through the entire range of torque. IMP reflects intrinsic mechanical properties of individual muscles, such as length-tension relationships, which EMG is unable to assess.

  7. Investigation of high-speed shaft bearing loads in wind turbine gearboxes through dynamometer testing

    DOE PAGES

    Guo, Yi; Keller, Jonathan

    2017-11-10

    Many wind turbine gearboxes require repair or replacement well before reaching the end of their design life. The most common failure is bearing axial cracks, commonly called white etching cracks (WECs), which typically occur in the inner raceways of the high-speed parallel-stage rolling element bearings. Although the root causes of WECs are debated, one theory is that they are related to routine dynamic operating conditions and occasional transient events prevalent in wind turbines that can result in high bearing stress and sliding of the rolling elements. Here, this paper examined wind turbine gearbox high-speed shaft bearing loads and stresses throughmore » modeling and full-scale dynamometer testing. Bearing outer race loads were directly measured and predicted using a variety of modeling tools in normal operations, misaligned conditions, and transient events particularly prone to bearing sliding. Test data and models of bearing loads were well correlated. Neither operational misalignment due to rotor moments nor static generator misalignment affected the bearing loads when compared with pure-torque conditions. Thus, it is not likely that generator misalignment is a causal factor of WECs. In contrast, during transient events, the bearings experienced alternating periods of high stress, torque reversals, and loads under the minimum requisite at high rotating speeds while showing indications of sliding, all of which could be related to the formation of WECs.« less

  8. Investigation of high-speed shaft bearing loads in wind turbine gearboxes through dynamometer testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, Yi; Keller, Jonathan

    Many wind turbine gearboxes require repair or replacement well before reaching the end of their design life. The most common failure is bearing axial cracks, commonly called white etching cracks (WECs), which typically occur in the inner raceways of the high-speed parallel-stage rolling element bearings. Although the root causes of WECs are debated, one theory is that they are related to routine dynamic operating conditions and occasional transient events prevalent in wind turbines that can result in high bearing stress and sliding of the rolling elements. Here, this paper examined wind turbine gearbox high-speed shaft bearing loads and stresses throughmore » modeling and full-scale dynamometer testing. Bearing outer race loads were directly measured and predicted using a variety of modeling tools in normal operations, misaligned conditions, and transient events particularly prone to bearing sliding. Test data and models of bearing loads were well correlated. Neither operational misalignment due to rotor moments nor static generator misalignment affected the bearing loads when compared with pure-torque conditions. Thus, it is not likely that generator misalignment is a causal factor of WECs. In contrast, during transient events, the bearings experienced alternating periods of high stress, torque reversals, and loads under the minimum requisite at high rotating speeds while showing indications of sliding, all of which could be related to the formation of WECs.« less

  9. Effects of humeral head compression taping on the isokinetic strength of the shoulder external rotator muscle in patients with rotator cuff tendinitis.

    PubMed

    Kim, Moon-Hwan; Oh, Jae-Seop

    2015-01-01

    [Purpose] The purpose of this study was to examine the effects of humeral head compression taping (HHCT) on the strength of the shoulder external rotator muscle in patients with rotator cuff tendinitis. [Subjects and Methods] Twenty patients with rotator cuff tendinitis were recruited. The shoulder external rotator strength was measured using a Biodex isokinetic dynamometer system. A paired t-test was performed to evaluate within-group differences in the strength of the shoulder external rotator muscle. [Results] Significantly higher shoulder external rotator peak torque and peak torque per body weight were found in the HHCT condition than in the no-taping condition. [Conclusion] HHCT may effectively increase the shoulder external rotator muscle strength in patients with rotator cuff tendinitis.

  10. Interdependence of torque, joint angle, angular velocity and muscle action during human multi-joint leg extension.

    PubMed

    Hahn, Daniel; Herzog, Walter; Schwirtz, Ansgar

    2014-08-01

    Force and torque production of human muscles depends upon their lengths and contraction velocity. However, these factors are widely assumed to be independent of each other and the few studies that dealt with interactions of torque, angle and angular velocity are based on isolated single-joint movements. Thus, the purpose of this study was to determine force/torque-angle and force/torque-angular velocity properties for multi-joint leg extensions. Human leg extension was investigated (n = 18) on a motor-driven leg press dynamometer while measuring external reaction forces at the feet. Extensor torque in the knee joint was calculated using inverse dynamics. Isometric contractions were performed at eight joint angle configurations of the lower limb corresponding to increments of 10° at the knee from 30 to 100° of knee flexion. Concentric and eccentric contractions were performed over the same range of motion at mean angular velocities of the knee from 30 to 240° s(-1). For contractions of increasing velocity, optimum knee angle shifted from 52 ± 7 to 64 ± 4° knee flexion. Furthermore, the curvature of the concentric force/torque-angular velocity relations varied with joint angles and maximum angular velocities increased from 866 ± 79 to 1,238 ± 132° s(-1) for 90-50° knee flexion. Normalised eccentric forces/torques ranged from 0.85 ± 0.12 to 1.32 ± 0.16 of their isometric reference, only showing significant increases above isometric and an effect of angular velocity for joint angles greater than optimum knee angle. The findings reveal that force/torque production during multi-joint leg extension depends on the combined effects of angle and angular velocity. This finding should be accounted for in modelling and optimisation of human movement.

  11. Relationships Between Knee Extension Moments During Weighted and Unweighted Gait and Strength Measures That Predict Knee Moments After ACL Reconstruction.

    PubMed

    Hartigan, Erin; Aucoin, Jennifer; Carlson, Rita; Klieber-Kusak, Melanie; Murray, Thomas; Shaw, Bernadette; Lawrence, Michael

    Weighted gait increases internal knee extension moment impulses (KEMI) in the anterior cruciate ligament-reconstructed (ACLR) limb; however, limb differences persist. (1) KEMI during normal gait will influence KEMI during weighted gait and (2) peak knee extension (PKE) torque and time to reach PKE torque will predict KEMI during gait tasks. Descriptive laboratory study. Twenty-four women and 14 men completed 3 gait tasks (unweighted, vest, sled) and strength testing after discharge from rehabilitation and clearance to return to sports. KEMI were calculated during the first 25% of stance. PKE torque and time to reach PKE torque were obtained using a dynamometer. Data on the ACLR limb and symmetry indices (SIs) were analyzed for each sex. Women presented with asymmetrical PKE torques and KEMI across tasks. There were three correlations noted for KEMI: between the walk and vest, walk and sled, and vest and sled tasks. Slower time to PKE torque predicted limb asymmetries across tasks and KEMI in the ACLR limb during the sled task. Men presented with asymmetrical PKE torques and KEMI during the sled task. There was a correlation noted for KEMI between walk and vest tasks only. During the sled task, ACLR limb time to PKE torque predicted KEMI in the ACLR limb and PKE torque SI predicted KEMI SI. Women use asymmetrical KEMI profiles during all gait tasks, and those with worse KEMI during walking have worse KEMI during weighted gait. Men have asymmetrical KEMI when sled towing, and these KEMIs do not correlate with KEMI during walking or vest tasks. PKE torque deficits persist when attempting to return to sports. Only men use gains in PKE torque to improve KEMI profiles. Although quicker PKE torque generation will increase KEMI in women, normalization of KEMI profiles will not occur by increasing rate of force development only. Gait retraining is recommended to correct asymmetrical KEMI profiles used across gait tasks in women.

  12. Correlation and prediction of dynamic human isolated joint strength from lean body mass

    NASA Technical Reports Server (NTRS)

    Pandya, Abhilash K.; Hasson, Scott M.; Aldridge, Ann M.; Maida, James C.; Woolford, Barbara J.

    1992-01-01

    A relationship between a person's lean body mass and the amount of maximum torque that can be produced with each isolated joint of the upper extremity was investigated. The maximum dynamic isolated joint torque (upper extremity) on 14 subjects was collected using a dynamometer multi-joint testing unit. These data were reduced to a table of coefficients of second degree polynomials, computed using a least squares regression method. All the coefficients were then organized into look-up tables, a compact and convenient storage/retrieval mechanism for the data set. Data from each joint, direction and velocity, were normalized with respect to that joint's average and merged into files (one for each curve for a particular joint). Regression was performed on each one of these files to derive a table of normalized population curve coefficients for each joint axis, direction, and velocity. In addition, a regression table which included all upper extremity joints was built which related average torque to lean body mass for an individual. These two tables are the basis of the regression model which allows the prediction of dynamic isolated joint torques from an individual's lean body mass.

  13. Kilohertz and Low-Frequency Electrical Stimulation With the Same Pulse Duration Have Similar Efficiency for Inducing Isometric Knee Extension Torque and Discomfort.

    PubMed

    Medeiros, Flávia Vanessa; Bottaro, Martim; Vieira, Amilton; Lucas, Tiago Pires; Modesto, Karenina Arrais; Bo, Antonio Padilha L; Cipriano, Gerson; Babault, Nicolas; Durigan, João Luiz Quagliotti

    2017-06-01

    To test the hypotheses that, as compared with pulsed current with the same pulse duration, kilohertz frequency alternating current would not differ in terms of evoked-torque production and perceived discomfort, and as a result, it would show the same current efficiency. A repeated-measures design with 4 stimuli presented in random order was used to test 25 women: (1) 500-microsecond pulse duration, (2) 250-microsecond pulse duration, (3) 500-microsecond pulse duration and low carrier frequency (1 kHz), (4) 250-microsecond pulse duration and high carrier frequency (4 kHz). Isometric peak torque of quadriceps muscle was measured using an isokinetic dynamometer. Discomfort was measured using a visual analog scale. Currents with long pulse durations induced approximately 21% higher evoked torque than short pulse durations. In addition, currents with 500 microseconds delivered greater amounts of charge than stimulation patterns using 250-microsecond pulse durations (P < 0.05). All currents presented similar discomfort. There was no difference on stimulation efficiency with the same pulse duration. Both kilohertz frequency alternating current and pulsed current, with the same pulse duration, have similar efficiency for inducing isometric knee extension torque and discomfort. However, neuromuscular electrical stimulation (NMES) with longer pulse duration induces higher NMES-evoked torque, regardless of the carrier frequency. Pulse duration is an important variable that should receive more attention for an optimal application of NMES in clinical settings.

  14. Musculoskeletal profile of middle-aged Ving Tsun Chinese martial art practitioners

    PubMed Central

    Fong, Shirley S.M.; Chan, Jessie S.M.; Bae, Young-Hyeon; Yam, Timothy T.T.; Chung, Louisa M.Y.; Ma, Ada W.W.; Kuisma, Raija

    2017-01-01

    Abstract This cross-sectional exploratory study aimed to quantify and compare the axial and appendicular bone mineral density (BMD), muscle mass, and muscle strength of middle-aged practitioners of Ving Tsun (VT; a hard-style Chinese martial art) with those of nonpractitioners. Eighteen VT practitioners (mean age ± standard deviation = 51.8 ± 17.7 years; 12 men and six women) and 36 active controls (mean age ± standard deviation = 58.7 ± 11.0 years; 18 men and 18 women) participated in the study. All participants underwent a 1-day battery of musculoskeletal examinations. The BMD of the total radius, total hip, femoral neck, and lumbar spine was measured using dual-energy X-ray absorptiometry, as was the lean mass of the arm, leg, and trunk. Muscle strength of the upper and lower limbs was assessed using a Jamar dynamometer and an isokinetic dynamometer at 60°/second, respectively. VT-trained participants had a 11.5% higher total radius BMD (P = 0.023), a 17.8% higher leg lean mass (P = 0.014), a 56.4% higher isokinetic body weight-adjusted peak torque of the knee extensors (P < 0.001), a 60.8% higher isokinetic body weight-adjusted peak torque of knee flexors (P < 0.001), and a 31.4% shorter time to reach peak torque in the knee flexors (P = 0.001) than the active controls. No significant differences were found in any of the other musculoskeletal outcomes between the 2 groups (P > 0.05). Middle-aged VT practitioners displayed a higher total radius BMD and leg lean mass and better knee extensor and flexor muscular performances than their healthy active counterparts. Healthcare professionals may consider using this alternative method of training to improve the musculoskeletal health of middle-aged adults. PMID:28121945

  15. Musculoskeletal profile of middle-aged Ving Tsun Chinese martial art practitioners: A cross-sectional study.

    PubMed

    Fong, Shirley S M; Chan, Jessie S M; Bae, Young-Hyeon; Yam, Timothy T T; Chung, Louisa M Y; Ma, Ada W W; Kuisma, Raija

    2017-01-01

    This cross-sectional exploratory study aimed to quantify and compare the axial and appendicular bone mineral density (BMD), muscle mass, and muscle strength of middle-aged practitioners of Ving Tsun (VT; a hard-style Chinese martial art) with those of nonpractitioners.Eighteen VT practitioners (mean age ± standard deviation = 51.8 ± 17.7 years; 12 men and six women) and 36 active controls (mean age ± standard deviation = 58.7 ± 11.0 years; 18 men and 18 women) participated in the study. All participants underwent a 1-day battery of musculoskeletal examinations. The BMD of the total radius, total hip, femoral neck, and lumbar spine was measured using dual-energy X-ray absorptiometry, as was the lean mass of the arm, leg, and trunk. Muscle strength of the upper and lower limbs was assessed using a Jamar dynamometer and an isokinetic dynamometer at 60°/second, respectively.VT-trained participants had a 11.5% higher total radius BMD (P = 0.023), a 17.8% higher leg lean mass (P = 0.014), a 56.4% higher isokinetic body weight-adjusted peak torque of the knee extensors (P < 0.001), a 60.8% higher isokinetic body weight-adjusted peak torque of knee flexors (P < 0.001), and a 31.4% shorter time to reach peak torque in the knee flexors (P = 0.001) than the active controls. No significant differences were found in any of the other musculoskeletal outcomes between the 2 groups (P > 0.05).Middle-aged VT practitioners displayed a higher total radius BMD and leg lean mass and better knee extensor and flexor muscular performances than their healthy active counterparts. Healthcare professionals may consider using this alternative method of training to improve the musculoskeletal health of middle-aged adults.

  16. Assessing the therapeutic effect of 625-nm light-emitting diodes

    NASA Astrophysics Data System (ADS)

    Mao, Zongzhen; Xu, Guodong; Yang, Yi

    2014-09-01

    To evaluate the effects of red Light-Emitting Diodes on elbow extensor and flexor strength and the recovery of exercise induced fatigue, the torque values from the isokinetic dynamometer as well as biochemistry parameters were used as outcome measures. A randomized double-blind placebo-controlled crossover trial was performed with twenty male young tennis athletes. Active LED therapy (LEDT, with wavelength 625nm, 10 minutes total irradiation time, irradiated area amount to 30cm2, and 900J of total energy irradiated) or an identical placebo was delivered under double-blinded conditions to the left elbow just before exercise. The isokinetic muscle strength was measured immediately after irradiation. The blood lactate levels were sampled pre-exercise and post-exercise. The peak torque values of elbow extensor strength were significantly different between two groups. As in elbow flexor strength, the difference of peak torque was not significant. The blood lactate concentration of LEDT group post-exercise was significantly lower than those of placebo group. The results indicate that 625nm LED therapy is effective in preventing muscle fatigue as it can significantly reduce peak torque value of elbow extensors and blood lactate concentration. It has no effect on the strength of left elbow flexor or backhand performance in tennis.

  17. A method and instruments to identify the torque, the power and the efficiency of an internal combustion engine of a wheeled vehicle

    NASA Astrophysics Data System (ADS)

    Egorov, A. V.; Kozlov, K. E.; Belogusev, V. N.

    2018-01-01

    In this paper, we propose a new method and instruments to identify the torque, the power, and the efficiency of internal combustion engines in transient conditions. This method, in contrast to the commonly used non-demounting methods based on inertia and strain gauge dynamometers, allows controlling the main performance parameters of internal combustion engines in transient conditions without inaccuracy connected with the torque loss due to its transfer to the driving wheels, on which the torque is measured with existing methods. In addition, the proposed method is easy to create, and it does not use strain measurement instruments, the application of which does not allow identifying the variable values of the measured parameters with high measurement rate; and therefore the use of them leads to the impossibility of taking into account the actual parameters when engineering the wheeled vehicles. Thus the use of this method can greatly improve the measurement accuracy and reduce costs and laboriousness during testing of internal combustion engines. The results of experiments showed the applicability of the proposed method for identification of the internal combustion engines performance parameters. In this paper, it was determined the most preferred transmission ratio when using the proposed method.

  18. Ankle and toe muscle strength characteristics in runners with a history of medial tibial stress syndrome.

    PubMed

    Saeki, Junya; Nakamura, Masatoshi; Nakao, Sayaka; Fujita, Kosuke; Yanase, Ko; Morishita, Katsuyuki; Ichihashi, Noriaki

    2017-01-01

    A high proportion of flexor digitorum longus attachment is found at the posteromedial border of the tibia, which is the most common location of medial tibial stress syndrome (MTSS). Therefore, plantar flexion strength of the lesser toes could be related to MTSS; however, the relationship between MTSS and muscle strength of the hallux and lesser toes is not yet evaluated due to the lack of quantitative methods. This study investigated the muscle strength characteristics in runners with a history of MTSS by using a newly developed device to measure the muscle strength of the hallux, lesser toes, and ankle. This study comprised 27 collegiate male runner participants (20.0 ± 1.6 years, 172.1 ± 5.1 cm, 57.5 ± 4.0 kg). Maximal voluntary isometric contraction (MVIC) torque of the plantar flexion, dorsiflexion, inversion, and eversion of the ankle were measured by using an electric dynamometer. MVIC torque of the 1st metatarsophalangeal joint (MTPJ) and 2nd-5th MTPJ were measured by using a custom-made torque-measuring device. MVIC torques were compared between runners with and without a history of MTSS. MVIC torque of the 1st MTPJ plantar flexion was significantly higher in runners with a history of MTSS than in those without it. In contrast, there were no significant differences in the MVIC torque values of the 2nd-5th MTPJ plantar flexion and each MVIC torque of the ankle between runners with and without a history of MTSS. A history of MTSS increased the isometric FHL strength.

  19. Strength deficits of the shoulder complex during isokinetic testing in people with chronic stroke

    PubMed Central

    Nascimento, Lucas R.; Teixeira-Salmela, Luci F.; Polese, Janaine C.; Ada, Louise; Faria, Christina D. C. M.; Laurentino, Glória E. C.

    2014-01-01

    OBJECTIVES: To examine the strength deficits of the shoulder complex after stroke and to characterize the pattern of weakness according to type of movement and type of isokinetic parameter. METHOD: Twelve chronic stroke survivors and 12 age-matched healthy controls had their shoulder strength measured using a Biodex isokinetic dynamometer. Concentric measures of peak torque and work during shoulder movements were obtained in random order at speeds of 60°/s for both groups and sides. Type of movement was defined as scapulothoracic (protraction and retraction), glenohumeral (shoulder internal and external rotation) or combined (shoulder flexion and extension). Type of isokinetic parameter was defined as maximum (peak torque) or sustained (work). Strength deficits were calculated using the control group as reference. RESULTS: The average strength deficit for the paretic upper limb was 52% for peak torque and 56% for work. Decreases observed in the non-paretic shoulder were 21% and 22%, respectively. Strength deficit of the scapulothoracic muscles was similar to the glenohumeral muscles, with a mean difference of 6% (95% CI -5 to 17). Ability to sustain torque throughout a given range of motion was decreased as much as the peak torque, with a mean difference of 4% (95% CI -2 to 10). CONCLUSIONS: The findings suggest that people after stroke might benefit from strengthening exercises directed at the paretic scapulothoracic muscles in addition to exercises of arm elevation. Clinicians should also prescribe different exercises to improve the ability to generate force and the ability to sustain the torque during a specific range of motion. PMID:25003280

  20. Reliability of metatarsophalangeal and ankle joint torque measurements by an innovative device.

    PubMed

    Man, Hok-Sum; Leung, Aaron Kam-Lun; Cheung, Jason Tak-Man; Sterzing, Thorsten

    2016-07-01

    The toe flexor muscles maintain body balance during standing and provide push-off force during walking, running, and jumping. Additionally, they are important contributing structures to maintain normal foot function. Thus, weakness of these muscles may cause poor balance, inefficient locomotion and foot deformities. The quantification of metatarsophalangeal joint (MPJ) stiffness is valuable as it is considered as a confounding factor in toe flexor muscles function. MPJ and ankle joint stiffness measurement is still largely depended on manual skills as current devices do not have good control on alignment, angular joint speed and displacement during measurement. Therefore, this study introduces an innovative dynamometer and protocol procedures for MPJ and ankle Joint torque measurement with precise and reliable foot alignment, angular joint speed and displacement control. Within-day and between-day test-retest experiments on MPJ and ankle joint torque measurement were conducted on ten and nine healthy male subjects respectively. The mean peak torques of MPJ and ankle joint of between-day and within-day measurement were 1.50±0.38Nm/deg and 1.19±0.34Nm/deg. The corresponding torques of the ankle joint were 8.24±2.20Nm/deg and 7.90±3.18Nm/deg respectively. Intraclass-correlation coefficients (ICC) of averaged peak torque of both joints of between-day and within-day test-retest experiments were ranging from 0.91 to 0.96, indicating the innovative device is systematic and reliable for the measurements and can be used for multiple scientific and clinical purposes. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Do patients with diabetic neuropathy use a higher proportion of their maximum strength when walking?

    PubMed

    Brown, Steven J; Handsaker, Joseph C; Bowling, Frank L; Maganaris, Costantinos N; Boulton, Andrew J M; Reeves, Neil D

    2014-11-28

    Diabetic patients have an altered gait strategy during walking and are known to be at high risk of falling, especially when diabetic peripheral neuropathy is present. This study investigated alterations to lower limb joint torques during walking and related these torques to maximum strength in an attempt to elucidate why diabetic patients are more likely to fall. 20 diabetic patients with moderate/severe peripheral neuropathy (DPN), 33 diabetic patients without peripheral neuropathy (DM), and 27 non-diabetic controls (Ctrl) underwent gait analysis using a motion analysis system and force plates to measure kinetic parameters. Lower limb peak joint torques and joint work done (energy expenditure) were calculated during walking. The ratio of peak joint torques and individual maximum joint strengths (measured on a dynamometer) was then calculated for 59 of the 80 participants to yield the ‘operating strength’ for those participants. During walking DM and DPN patients showed significantly reduced peak torques at the ankle and knee. Maximum joint strengths at the knee were significantly less in both DM and DPN groups than Ctrls, and for the DPN group at the ankle. Operating strengths were significantly higher at the ankle in the DPN group compared to the Ctrls. These findings show that diabetic patients walk with reduced lower limb joint torques; however due to a decrement in their maximum ability at the ankle and knee, their operating strengths are higher. This allows less reserve strength if responding to a perturbation in balance, potentially increasing their risk of falling.

  2. STS-78 Flight Day 4

    NASA Technical Reports Server (NTRS)

    1996-01-01

    On this fourth day of the STS-78 mission, the flight crew, Cmdr. Terence T. Henricks, Pilot Kevin R. Kregel, Payload Cmdr. Susan J. Helms, Mission Specialists Richard M. Linnehan, Charles E. Brady, Jr., and Payload Specialists Jean-Jacques Favier, Ph.D. and Robert B. Thirsk, M.D., discuss the flight during an interview with the Cable News Network (CNN). The crew then continues research concentrated on the Torque Velocity Dynamometer measurements of leg and arm muscle power, the Astronaut Lung Function Experiment, and effects of microgravity exercise with the bicycle ergometer and its associated instruments.

  3. Muscle Strength Imbalance in the Hip Joint Caused by Fast Movements

    NASA Astrophysics Data System (ADS)

    Pontaga, I.

    2003-07-01

    Eleven male sportsmen at the age of 24.3 ± 4.5 were examined. Their hip joint flexors and extensors were tested by an "REV-9000" Technogym dynamometer system during isokinetic movements at angular velocities of 100 (low) and 200 (high) °/s. The range of hip joint movements was from 30 (in flexion) to 130° (in extension). Torque values and their ratios for hip flexors and extensors at different angular positions were obtained and compared. It is shown that, at high speeds, the flexion movement significantly raises ( p < 0.001) the torque ratios of flexors and extensors in flexion positions of the hip (50 and 60°). These ratios approximately twofold exceed their values at moderate velocities. The weakness of hip joint extensors in extreme flexion positions of the hip may cause injury of this group of muscles at fast movements.

  4. Reproducibility of the time to peak torque and the joint angle at peak torque on knee of young sportsmen on the isokinetic dynamometer.

    PubMed

    Bernard, P-L; Amato, M; Degache, F; Edouard, P; Ramdani, S; Blain, H; Calmels, P; Codine, P

    2012-05-01

    Although peak torque has shown acceptable reproducibility, this may not be the case with two other often used parameters: time to peak torque (TPT) and the angle of peak torque (APT). Those two parameters should be used for the characterization of muscular adaptations in athletes. The isokinetic performance of the knee extensors and flexors in both limbs was measured in 29 male athletes. The experimental protocol consisted of three consecutive identical paradigms separated by 45 min breaks. Each test consisted of four maximal concentric efforts performed at 60 and 180°/s. Reproducibility was quantified by the standard error measurement (SEM), the coefficient of variation (CV) and by means of intra-class correlation coefficients (ICCs) with the calculation of 6 forms of ICCs. Using ICC as the indicator of reproducibility, the correlations for TPT of both limbs showed a range of 0.51-0.65 in extension and 0.50-0.63 in flexion. For APT, the values were 0.46-0.60 and 0.51-0.81, respectively. In addition, the calculated standard error of measurement (SEM) and CV scores confirmed the low level of absolute reproducibility. Due to their low reproducibility, neither TPT nor APT can serve as independent isokinetic parameters of knee flexor and extensor performance. So, given its reproducibility level, TPT and APT should not be used for the characterization of muscular adaptations in athletes. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  5. Exploratory factor analysis for differentiating sensory and mechanical variables related to muscle-tendon unit elongation

    PubMed Central

    Chagas, Mauro H.; Magalhães, Fabrício A.; Peixoto, Gustavo H. C.; Pereira, Beatriz M.; Andrade, André G. P.; Menzel, Hans-Joachim K.

    2016-01-01

    ABSTRACT Background Stretching exercises are able to promote adaptations in the muscle-tendon unit (MTU), which can be tested through physiological and biomechanical variables. Identifying the key variables in MTU adaptations is crucial to improvements in training. Objective To perform an exploratory factor analysis (EFA) involving the variables often used to evaluate the response of the MTU to stretching exercises. Method Maximum joint range of motion (ROMMAX), ROM at first sensation of stretching (FSTROM), peak torque (torqueMAX), passive stiffness, normalized stiffness, passive energy, and normalized energy were investigated in 36 participants during passive knee extension on an isokinetic dynamometer. Stiffness and energy values were normalized by the muscle cross-sectional area and their passive mode assured by monitoring the EMG activity. Results EFA revealed two major factors that explained 89.68% of the total variance: 53.13% was explained by the variables torqueMAX, passive stiffness, normalized stiffness, passive energy, and normalized energy, whereas the remaining 36.55% was explained by the variables ROMMAX and FSTROM. Conclusion This result supports the literature wherein two main hypotheses (mechanical and sensory theories) have been suggested to describe the adaptations of the MTU to stretching exercises. Contrary to some studies, in the present investigation torqueMAX was significantly correlated with the variables of the mechanical theory rather than those of the sensory theory. Therefore, a new approach was proposed to explain the behavior of the torqueMAX during stretching exercises. PMID:27437715

  6. Internal- and External-Rotation Peak Toque in Little League Baseball Players With Subacromial Impingement Syndrome: Improved by Closed Kinetic Chain Shoulder Training.

    PubMed

    Lee, Dong-Rour; Kim, Laurentius Jongsoon

    2016-08-01

    Many studies have explored closed kinetic chain (CKC) shoulder exercises (SEs) with a sling because they are safer and more effective than open-chain exercises, especially in early stages of treatment. However, the application of CKC SE in youth baseball players has rarely been attempted, although teenage baseball players also experience shoulder pain. To investigate the effects of CKC SE on the peak torque of shoulder internal rotation (IR) and external rotation (ER) in youth baseball players. Single-group pretest, posttest. Biomechanics laboratory. 23 Little League Baseball players with subacromial impingement syndrome. The CKC SE with a sling was CKC shoulder-flexion exercise, extension exercise, IR exercise, and ER exercise. This exercise regimen was conducted 2 or 3 times/wk for 8 wk. The peak torque of shoulder IR and ER was measured using an isokinetic dynamometer. Concentric shoulder rotation was performed, with 5 repetitions at an angular velocity of 60°/s and 15 at 180°/s. The IR and ER peak torque significantly increased at each angular velocity after the exercise program. In particular, the increase in IR and ER peak torque values was statistically significant at an angular velocity of 180°/s. CKC SE was effective in increasing shoulder IR and ER strength, demonstrating its potential benefits in the prevention and treatment of shoulder injury. In addition, increased IR peak torque appears to improve throwing velocity in baseball players.

  7. Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis

    PubMed Central

    Chamorro, Claudio; Armijo-Olivo, Susan; De la Fuente, Carlos; Fuentes, Javiera; Javier Chirosa, Luis

    2017-01-01

    Abstract The purpose of the study is to establish absolute reliability and concurrent validity between hand-held dynamometers (HHDs) and isokinetic dynamometers (IDs) in lower extremity peak torque assessment. Medline, Embase, CINAHL databases were searched for studies related to psychometric properties in muscle dynamometry. Studies considering standard error of measurement SEM (%) or limit of agreement LOA (%) expressed as percentage of the mean, were considered to establish absolute reliability while studies using intra-class correlation coefficient (ICC) were considered to establish concurrent validity between dynamometers. In total, 17 studies were included in the meta-analysis. The COSMIN checklist classified them between fair and poor. Using HHDs, knee extension LOA (%) was 33.59%, 95% confidence interval (CI) 23.91 to 43.26 and ankle plantar flexion LOA (%) was 48.87%, CI 35.19 to 62.56. Using IDs, hip adduction and extension; knee flexion and extension; and ankle dorsiflexion showed LOA (%) under 15%. Lower hip, knee, and ankle LOA (%) were obtained using an ID compared to HHD. ICC between devices ranged between 0.62, CI (0.37 to 0.87) for ankle dorsiflexion to 0.94, IC (0.91to 0.98) for hip adduction. Very high correlation were found for hip adductors and hip flexors and moderate correlations for knee flexors/extensors and ankle plantar/dorsiflexors. PMID:29071305

  8. Renewable Fuels and Lubricants Laboratory | Transportation Research | NREL

    Science.gov Websites

    delivery vans to full-size buses and Class 8 tractors. Heavy-Duty and Light-Duty Engine Dynamometer Test Cells The ReFUEL Laboratory features two engine dynamometer test cells-one for heavy-duty (up to 600 hp the Heavy-Duty Federal Test Procedures (HD-FTP), are highly standardized, and results can be readily

  9. The Influence of Glove Type on Simulated Wheelchair Racing Propulsion: A Pilot Study.

    PubMed

    Rice, I; Dysterheft, J; Bleakney, A W; Cooper, R A

    2016-01-01

    Our purpose was to examine the influence of glove type on kinetic and spatiotemporal parameters at the handrim in elite wheelchair racers. Elite wheelchair racers (n=9) propelled on a dynamometer in their own racing chairs with a force and moment sensing wheel attached. Racers propelled at 3 steady state speeds (5.36, 6.26 & 7.60 m/s) and performed one maximal effort sprint with 2 different glove types (soft & solid). Peak resultant force, peak torque, impulse, contact angle, braking torque, push time, velocity, and stroke frequency were recorded for steady state and sprint conditions. Multiple nonparametric Wilcoxon matched pair's tests were used to detect differences between glove types, while effect sizes were calculated based on Cohen's d. During steady state trials, racers propelled faster, using more strokes and larger contact angle, while applying less impulse with solid gloves compared to soft gloves. During the sprint condition, racers achieved greater top end velocities, applying larger peak force, with less braking torque with solid gloves compared to soft gloves. Use of solid gloves may provide some performance benefits to wheelchair racers during steady state and top end velocity conditions. © Georg Thieme Verlag KG Stuttgart · New York.

  10. A new device to study isoload eccentric exercise.

    PubMed

    Guilhem, Gaël; Cornu, Christophe; Nordez, Antoine; Guével, Arnaud

    2010-12-01

    This study was designed to develop a new device allowing mechanical analysis of eccentric exercise against a constant load, with a view in mind to compare isoload (IL) and isokinetic (IK) eccentric exercises. A plate-loaded resistance training device was integrated to an IK dynamometer, to perform the acquisition of mechanical parameters (i.e., external torque, angular velocity). To determine the muscular torque produced by the subject, load torque was experimentally measured (TLexp) at 11 different loads from 30° to 90° angle (0° = lever arm in horizontal position). TLexp was modeled to take friction effect and torque variations into account. Validity of modeled load torque (TLmod) was tested by determining the root mean square (RMS) error, bias, and 2SD between the descending part of TLexp (from 30° to 90°) and TLmod. Validity of TLexp was tested by a linear regression and a Passing-Bablok regression. A pilot analysis on 10 subjects was performed to determine the contribution of the torque because of the moment of inertia to the amount of external work (W). Results showed the validity of TLmod (bias = 0%; RMS error = 0.51%) and TLexp SEM = 4.1 N·m; Intraclass correlation coefficient (ICC) = 1.00; slope = 0.99; y-intercept = -0.13). External work calculation showed a satisfactory reproducibility (SEM = 38.3 J; ICC = 0.98) and moment of inertia contribution to W showed a low value (3.2 ± 2.0%). Results allow us to validate the new device developed in this study. Such a device could be used in future work to study IL eccentric exercise and to compare the effect of IL and IK eccentric exercises in standardized conditions.

  11. Acute effects of static stretching on passive stiffness of the hamstring muscles calculated using different mathematical models.

    PubMed

    Nordez, Antoine; Cornu, Christophe; McNair, Peter

    2006-08-01

    The aim of this study was to assess the effects of static stretching on hamstring passive stiffness calculated using different data reduction methods. Subjects performed a maximal range of motion test, five cyclic stretching repetitions and a static stretching intervention that involved five 30-s static stretches. A computerised dynamometer allowed the measurement of torque and range of motion during passive knee extension. Stiffness was then calculated as the slope of the torque-angle relationship fitted using a second-order polynomial, a fourth-order polynomial, and an exponential model. The second-order polynomial and exponential models allowed the calculation of stiffness indices normalized to knee angle and passive torque, respectively. Prior to static stretching, stiffness levels were significantly different across the models. After stretching, while knee maximal joint range of motion increased, stiffness was shown to decrease. Stiffness decreased more at the extended knee joint angle, and the magnitude of change depended upon the model used. After stretching, the stiffness indices also varied according to the model used to fit data. Thus, the stiffness index normalized to knee angle was found to decrease whereas the stiffness index normalized to passive torque increased after static stretching. Stretching has significant effects on stiffness, but the findings highlight the need to carefully assess the effect of different models when analyzing such data.

  12. Isokinetic knee joint evaluation in track and field events.

    PubMed

    Deli, Chariklia K; Paschalis, Vassilis; Theodorou, Anastasios A; Nikolaidis, Michalis G; Jamurtas, Athanasios Z; Koutedakis, Yiannis

    2011-09-01

    The purpose of this study was to evaluate maximal torque of the knee flexors and extensors, flexor/extensor ratios, and maximal torque differences between the 2 lower extremities in young track and field athletes. Forty male track and field athletes 13-17 years old and 20 male nonathletes of the same age participated in the study. Athletes were divided into 4 groups according to their age and event (12 runners and 10 jumpers 13-15 years old, 12 runners and 6 jumpers 16-17 years old) and nonathletes into 2 groups of the same age. Maximal torque evaluation of knee flexors and extensors was performed on an isokinetic dynamometer at 60°·s(-1). At the age of 16-17 years, jumpers exhibited higher strength values at extension than did runners and nonathletes, whereas at the age of 13-15 years, no significant differences were found between events. Younger athletes were weaker than older athletes at flexion. Runners and jumpers were stronger than nonathletes in all relative peak torque parameters. Nonathletes exhibited a higher flexor/extensor ratio compared with runners and jumpers. Strength imbalance in athletes was found between the 2 lower extremities in knee flexors and extensors and also at flexor/extensor ratio of the same extremity. Young track and field athletes exhibit strength imbalances that could reduce their athletic performance, and specific strength training for the weak extremity may be needed.

  13. Parallel elastic elements improve energy efficiency on the STEPPR bipedal walking robot

    DOE PAGES

    Mazumdar, Anirban; Spencer, Steven J.; Hobart, Clinton; ...

    2016-11-23

    This study describes how parallel elastic elements can be used to reduce energy consumption in the electric motor driven, fully-actuated, STEPPR bipedal walking robot without compromising or significantly limiting locomotive behaviors. A physically motivated approach is used to illustrate how selectively-engaging springs for hip adduction and ankle flexion predict benefits for three different flat ground walking gaits: human walking, human-like robot walking and crouched robot walking. Based on locomotion data, springs are designed and substantial reductions in power consumption are demonstrated using a bench dynamometer. These lessons are then applied to STEPPR (Sandia Transmission-Efficient Prototype Promoting Research), a fully actuatedmore » bipedal robot designed to explore the impact of tailored joint mechanisms on walking efficiency. Featuring high-torque brushless DC motors, efficient low-ratio transmissions, and high fidelity torque control, STEPPR provides the ability to incorporate novel joint-level mechanisms without dramatically altering high level control. Unique parallel elastic designs are incorporated into STEPPR, and walking data shows that hip adduction and ankle flexion springs significantly reduce the required actuator energy at those joints for several gaits. These results suggest that parallel joint springs offer a promising means of supporting quasi-static joint torques due to body mass during walking, relieving motors of the need to support these torques and substantially improving locomotive energy efficiency.« less

  14. Parallel elastic elements improve energy efficiency on the STEPPR bipedal walking robot

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mazumdar, Anirban; Spencer, Steven J.; Hobart, Clinton

    This study describes how parallel elastic elements can be used to reduce energy consumption in the electric motor driven, fully-actuated, STEPPR bipedal walking robot without compromising or significantly limiting locomotive behaviors. A physically motivated approach is used to illustrate how selectively-engaging springs for hip adduction and ankle flexion predict benefits for three different flat ground walking gaits: human walking, human-like robot walking and crouched robot walking. Based on locomotion data, springs are designed and substantial reductions in power consumption are demonstrated using a bench dynamometer. These lessons are then applied to STEPPR (Sandia Transmission-Efficient Prototype Promoting Research), a fully actuatedmore » bipedal robot designed to explore the impact of tailored joint mechanisms on walking efficiency. Featuring high-torque brushless DC motors, efficient low-ratio transmissions, and high fidelity torque control, STEPPR provides the ability to incorporate novel joint-level mechanisms without dramatically altering high level control. Unique parallel elastic designs are incorporated into STEPPR, and walking data shows that hip adduction and ankle flexion springs significantly reduce the required actuator energy at those joints for several gaits. These results suggest that parallel joint springs offer a promising means of supporting quasi-static joint torques due to body mass during walking, relieving motors of the need to support these torques and substantially improving locomotive energy efficiency.« less

  15. Development of an integrated digital hand grip dynamometer and norm of hand grip strength.

    PubMed

    Chang, Ho; Chen, Chih-Hao; Huang, Tung-Sun; Tai, Chun-Yen

    2015-01-01

    This study designs and fabricates a novel integrated digital hand grip dynamometer and analyzes collected grip strength data. The dynamometer directly stores collected data in a computer, unlike those on the market that cannot directly store information. A strain gauge load cell is used as a force sensor. The dynamometer is designed to maximize ergonomics. Excitation voltage of the load cell is 5 V, and a 9 V battery supplies power to its circuit. The signal receiver is National Instruments (NI) data acquisition (DAQ) card that transmits signals to the computer. The operation system is designed using LabView. This study assesses the correlation between variables of collected data. The correlation coefficients for height, weight and palm length were 0.793, 0.609 and 0.715, respectively, indicating that variables were moderately to strongly correlate with grip strength.

  16. TVD, Linnehan collects data during LMS-1 Spacelab mission

    NASA Image and Video Library

    1996-07-09

    STS078-430-009 (20 June-7 July 1996) --- Astronaut Richard M. Linnehan, mission specialist, performs a test on his leg using the Torque Velocity Dynamometer (TVD). Dr. Thirsk was measuring changes in muscle forces of the leg in this particular view. The TVD hardware is also used to measure arm muscle forces and velocity at the bicep and tricep areas. Crewmembers for the mission performed all experiment protocols prior to flight to develop a baseline and will also perform post-flight tests to complete the analysis. Additionally, muscle biopsies were taken before the flight and will be conducted after the flight.

  17. Determination the validity of the new developed Sport Experts® hand grip dynamometer, measuring continuity of force, and comparison with current Takei and Baseline® dynamometers.

    PubMed

    Güçlüöver, A; Kutlu, M; Ciğerci, A E; Esen, H T; Demirkan, E; Erdoğdu, M

    2015-11-01

    In this study the Sport Experts ™ brand of hand grip dynamometer, measuring the continuity of force with the new developed load cell technology, was compared with Takei and Baseline® dynamometers, the current in use. It was tried to determine the correlation between them. In a study with provides use of clinical, orthopedic and rehabilitative purposes in the athletes and patient populations, this developed dynamometer can provide useful data by observing the continuity of force. The sample of the study included 60 badminton players in 2010-2011; consisting of Turkish Junior National male players (N.=16, age: 16.8±1.5), Junior National female players (N.=14, age: 16.9±1.6), amateur level male players (N.=15, age: 16.3±0.8) and amateur level female players (N.=15, age: 16.1±0.6). ANOVA was used in the statistical methods in order to compare the hand grip strength made by different brands; Pearson's correlation coefficient was used to determine the relationship level between dynamometers. Furthermore, test-retest reliability analysis was completed the new developed expert dynamometer. There was no statistically significant difference in the comparison of the dynamometers (P>0.05). Besides, a highly significant relationship (r=0.95 to 0.96) was found among all three dynamometers. However, the reliability coefficient was found (Chronbachs α: 0.989, ICC:0.97, r=0.97), (P<0.01) for the new developed expert dynamometer. Comparison between the dynamometers and the statistical results obtained from the correlation relationships shows interchangeability of dynamometers. As a result, our observation of force continuity (progression) of the athlete and patient populations is thought to be important.

  18. Shoulder isokinetic profile of male handball players of the Brazilian National Team

    PubMed Central

    Andrade, Marília S.; Vancini, Rodrigo L.; de Lira, Claudio A. B.; Mascarin, Naryana C.; Fachina, Rafael J. F. G.; da Silva, Antonio C.

    2013-01-01

    Background Data obtained on an isokinetic dynamometer are useful to characterize muscle status and have been reported in muscle imbalance studies in different types of sport. However, few studies have assessed elite handball players to establish reference values. Objective The purpose of this study was to compare, for the dominant (D) and non-dominant (ND) side, the isokinetic profile of shoulder rotator muscle strength between male handball players (H) and asymptomatic non-athletes (NA). Method Isokinetic concentric and eccentric strength tests for D upper limbs were performed by the H group (n=20) and the NA group (n=12). Internal and external rotator muscle peak torque in concentric action was assessed at 60°/s and 300°/s and in eccentric action at 300°/s. We also calculated conventional balance (the ratio of external rotator peak torque to internal rotator peak torque in concentric action) and functional balance (the ratio of external rotator peak torque in eccentric action to internal rotator peak torque in concentric action). Results In the H group, dominant limbs were stronger in concentric action for external rotation at 60 and 300°/s. The conventional balance ratio for the D side was significantly lower at 60 and 300°/s for H compared to NA. The functional ratio for the D side was significantly lower at 300º/s for H compared to NA. Conclusions Compared to asymptomatic non-athletes, handball players presented significant muscular imbalance resulting from daily sports practice, a known risk factor for shoulder injuries. PMID:24271090

  19. Concentric and eccentric torque of the hip musculature in individuals with and without patellofemoral pain.

    PubMed

    Boling, Michelle C; Padua, Darin A; Alexander Creighton, R

    2009-01-01

    Individuals suffering from patellofemoral pain have previously been reported to have decreased isometric strength of the hip musculature; however, no researchers have investigated concentric and eccentric torque of the hip musculature in individuals with patellofemoral pain. To compare concentric and eccentric torque of the hip musculature in individuals with and without patellofemoral pain. Case control. Research laboratory. Twenty participants with patellofemoral pain (age = 26.8 +/- 4.5 years, height = 171.8 +/- 8.4 cm, mass = 72.4 +/- 16.8 kg) and 20 control participants (age = 25.6 +/- 2.8 years, height = 169.5 +/- 8.9 cm, mass = 70.0 +/- 16.9 kg) were tested. Volunteers with patellofemoral pain met the following criteria: knee pain greater than or equal to 3 cm on a 10-cm visual analog scale, insidious onset of symptoms not related to trauma, pain with palpation of the patellar facets, and knee pain during 2 of the following activities: stair climbing, jumping or running, squatting, kneeling, or prolonged sitting. Control participants were excluded if they had a prior history of patellofemoral pain, knee surgery in the past 2 years, or current lower extremity injury that limited participation in physical activity. Concentric and eccentric torque of the hip musculature was measured on an isokinetic dynamometer. All volunteers performed 5 repetitions of each strength test. Separate multivariate analyses of variance were performed to compare concentric and eccentric torque of the hip extensors, abductors, and external rotators between groups. Average and peak concentric and eccentric torque of the hip extensors, abductors, and external rotators. Torque measures were normalized to the participant's body weight multiplied by height. The patellofemoral pain group was weaker than the control group for peak eccentric hip abduction torque (F(1,38) = 6.630, P = .014), and average concentric (F(1,38) = 4.156, P = .048) and eccentric (F(1,38) = 4.963, P = .032) hip external rotation torque. The patellofemoral pain group displayed weakness in eccentric hip abduction and hip external rotation, which may allow for increased hip adduction and internal rotation during functional movements.

  20. Isokinetic hamstrings-to-quadriceps peak torque ratio: the influence of sport modality, gender, and angular velocity.

    PubMed

    Andrade, Marilia Dos Santos; De Lira, Claudio Andre Barbosa; Koffes, Fabiana De Carvalho; Mascarin, Naryana Cristina; Benedito-Silva, Ana Amélia; Da Silva, Antonio Carlos

    2012-01-01

    The purpose of this study was to determine differences in hamstrings-to-quadriceps (H/Q) peak torque ratios evaluated at different angular velocities between men and women who participate in judo, handball or soccer. A total of 166 athletes, including 58 judokas (26 females and 32 males), 39 handball players (22 females and 17 males), and 69 soccer players (17 females and 52 males), were evaluated using an isokinetic dynamometer. The H/Q isokinetic peak torque ratios were calculated at angular velocities of 1.05 rad · s⁻¹ and 5.23 rad · s⁻¹. In the analysis by gender, female soccer players produced lower H/Q peak torque ratios at 1.05 rad · s⁻¹ than males involved in the same sport. However, when H/Q peak torque ratio was assessed at 5.23 rad · s⁻¹, there were no significant differences between the sexes. In the analysis by sport, there were no differences among females at 1.05 rad · s⁻¹. In contrast, male soccer players had significantly higher H/Q peak torque ratios than judokas (66 ± 12% vs. 57 ± 14%, respectively). Female handball players produced significantly lower peak torque ratios at 5.23 rad · s⁻¹ than judokas or soccer players, whereas males presented no ratio differences among sports At 5.23 rad · s⁻¹. In the analysis by velocity, women's muscular ratios assessed at 1.05 rad · s⁻¹ were significantly lower than at 5.23 rad · s⁻¹ for all sports; among men, only judokas presented lower ratios at 1.05 rad · s⁻¹ than at 5.23 rad · s⁻¹. The present results suggest that sport modality and angular velocity influence the isokinetic strength profiles of men and women.

  1. Isokinetic strength and endurance after percutaneous and open surgical repair of Achilles tendon ruptures.

    PubMed

    Goren, David; Ayalon, Moshe; Nyska, Meir

    2005-04-01

    Reports on complete spontaneous Achilles tendon ruptures and associated treatment have become more frequent in the literature in the past two decades, as has the request for treatments that enable the finest possible functional recovery. The best available treatment is a matter of considerable controversy in the literature. The purpose of this study was to compare the isokinetic strength and endurance of the plantarflexor muscle-tendon unit in subjects who sustained rupture of the Achilles tendon and underwent either open surgery or closed percutaneous repair of the Achilles tendon. Twenty patients (18 males, 2 females) with spontaneous ruptures of the Achilles tendon were included in this study. Ten patients were treated by open surgery, and 10 patients were treated percutaneously. All patients had ruptured their Achilles tendon more than 6 months before the study, and all of the ruptures occurred 3.5 years or less before the day of the testing. All patients underwent an oriented physical examination. An isokinetic Biodex dynamometer (Biodex Medical System, Shirley, NY) was used to measure ankle joint angle, and in plantarflexion to calculate the torque at the ankle joint (Newton/meter), and the average work (jouls) for both maximal power and endurance. Each measurement was compared to the normal ankle. Biodex dynamometer evaluations at 90 deg/sec demonstrated a significant difference of maximal voluntary plantarflexor torque, endurance performance and range of motion at the ankle joint between the involved and uninvolved sides in patients treated by either mode of treatment. Yet, no statistically significant differences were revealed for the parameters mentioned above between the subjects that were treated either percutaneously or by an open surgery. In functional terms, the biomechanical outcomes of open surgery and percutaneous repair for acute ruptures of the Achilles tendon are both effective.

  2. Influence of patellofemoral bracing on pain, knee extensor torque, and gait function in females with patellofemoral pain.

    PubMed

    Powers, Christopher M; Doubleday, Kathryn L; Escudero, Carina

    2008-01-01

    Our purpose was to evaluate the effects of a patellofemoral brace on pain response, knee extensor torque production, and gait function in females with patellofemoral pain (PFP). Sixteen females between the ages of 14 and 46 with diagnosis of PFP participated. Knee extensor torque was measured by using a LIDO isokinetic dynamometer. Pain levels were documented by using the Visual Analog Pain Scale. Stride characteristics during the conditions of free walk, fast walk, ascend stairs, descend stairs, ascend ramp, and descend ramp were obtained with a stride analyzer unit. EMG activity of the vasti musculature was recorded by using indwelling, bipolar, wire electrodes. Knee joint motion was assessed by using a VICON motion analysis system. All testing was performed with and without the Bauerfeind Genutrain P3 patellofemoral brace. There were no significant differences in torque production, pain levels, and stride characteristics between braced and non-braced trials. In addition, there were no significant differences in mean vasti EMG between braced and non-braced trials. When averaged across all conditions, a small but statistically significant increase in knee flexion was found during the braced trials. Although the current study did not find significant improvements in the clinical measures evaluated, 8 of the 16 subjects did experience a decrease in knee pain. This finding suggests that certain patients with PFP may respond favorably to bracing, and criteria must be established to determine which patients would best benefit from such an intervention.

  3. Cardiorespiratory Fitness and Peak Torque Differences between Vegetarian and Omnivore Endurance Athletes: A Cross-Sectional Study

    PubMed Central

    Lynch, Heidi M.; Wharton, Christopher M.; Johnston, Carol S.

    2016-01-01

    In spite of well-documented health benefits of vegetarian diets, less is known regarding the effects of these diets on athletic performance. In this cross-sectional study, we compared elite vegetarian and omnivore adult endurance athletes for maximal oxygen uptake (VO2 max) and strength. Twenty-seven vegetarian (VEG) and 43 omnivore (OMN) athletes were evaluated using VO2 max testing on the treadmill, and strength assessment using a dynamometer to determine peak torque for leg extensions. Dietary data were assessed using detailed seven-day food logs. Although total protein intake was lower among vegetarians in comparison to omnivores, protein intake as a function of body mass did not differ by group (1.2 ± 0.3 and 1.4 ± 0.5 g/kg body mass for VEG and OMN respectively, p = 0.220). VO2 max differed for females by diet group (53.0 ± 6.9 and 47.1 ± 8.6 mL/kg/min for VEG and OMN respectively, p < 0.05) but not for males (62.6 ± 15.4 and 55.7 ± 8.4 mL/kg/min respectively). Peak torque did not differ significantly between diet groups. Results from this study indicate that vegetarian endurance athletes’ cardiorespiratory fitness was greater than that for their omnivorous counterparts, but that peak torque did not differ between diet groups. These data suggest that vegetarian diets do not compromise performance outcomes and may facilitate aerobic capacity in athletes. PMID:27854281

  4. Cardiorespiratory Fitness and Peak Torque Differences between Vegetarian and Omnivore Endurance Athletes: A Cross-Sectional Study.

    PubMed

    Lynch, Heidi M; Wharton, Christopher M; Johnston, Carol S

    2016-11-15

    In spite of well-documented health benefits of vegetarian diets, less is known regarding the effects of these diets on athletic performance. In this cross-sectional study, we compared elite vegetarian and omnivore adult endurance athletes for maximal oxygen uptake (VO2 max) and strength. Twenty-seven vegetarian (VEG) and 43 omnivore (OMN) athletes were evaluated using VO2 max testing on the treadmill, and strength assessment using a dynamometer to determine peak torque for leg extensions. Dietary data were assessed using detailed seven-day food logs. Although total protein intake was lower among vegetarians in comparison to omnivores, protein intake as a function of body mass did not differ by group (1.2 ± 0.3 and 1.4 ± 0.5 g/kg body mass for VEG and OMN respectively, p = 0.220). VO2 max differed for females by diet group (53.0 ± 6.9 and 47.1 ± 8.6 mL/kg/min for VEG and OMN respectively, p < 0.05) but not for males (62.6 ± 15.4 and 55.7 ± 8.4 mL/kg/min respectively). Peak torque did not differ significantly between diet groups. Results from this study indicate that vegetarian endurance athletes' cardiorespiratory fitness was greater than that for their omnivorous counterparts, but that peak torque did not differ between diet groups. These data suggest that vegetarian diets do not compromise performance outcomes and may facilitate aerobic capacity in athletes.

  5. Sprint Acceleration Mechanics: The Major Role of Hamstrings in Horizontal Force Production

    PubMed Central

    Morin, Jean-Benoît; Gimenez, Philippe; Edouard, Pascal; Arnal, Pierrick; Jiménez-Reyes, Pedro; Samozino, Pierre; Brughelli, Matt; Mendiguchia, Jurdan

    2015-01-01

    Recent literature supports the importance of horizontal ground reaction force (GRF) production for sprint acceleration performance. Modeling and clinical studies have shown that the hip extensors are very likely contributors to sprint acceleration performance. We experimentally tested the role of the hip extensors in horizontal GRF production during short, maximal, treadmill sprint accelerations. Torque capabilities of the knee and hip extensors and flexors were assessed using an isokinetic dynamometer in 14 males familiar with sprint running. Then, during 6-s sprints on an instrumented motorized treadmill, horizontal and vertical GRF were synchronized with electromyographic (EMG) activity of the vastus lateralis, rectus femoris, biceps femoris, and gluteus maximus averaged over the first half of support, entire support, entire swing and end-of-swing phases. No significant correlations were found between isokinetic or EMG variables and horizontal GRF. Multiple linear regression analysis showed a significant relationship (P = 0.024) between horizontal GRF and the combination of biceps femoris EMG activity during the end of the swing and the knee flexors eccentric peak torque. In conclusion, subjects who produced the greatest amount of horizontal force were both able to highly activate their hamstring muscles just before ground contact and present high eccentric hamstring peak torque capability. PMID:26733889

  6. TVD, Thirsk collects data during LMS-1 Spacelab mission

    NASA Image and Video Library

    1996-07-09

    STS078-304-018 (20 June - 7 July 1996) --- Payload specialist Robert B. Thirsk, representing the Canadian Space Agency (CSA), performs a test on his arm using the Torque Velocity Dynamometer (TVD). Dr. Thirsk was measuring changes in muscle forces of the bicep and tricep in this particular view. The TVD hardware is also used to measure leg muscle forces and velocity at the ankle and elbow joints. Crew members for the mission performed all experiment protocols prior to flight to develop a baseline and will also perform post-flight tests to complete the analysis. Additionally, muscle biopsies were taken before the flight and will be conducted after the flight.

  7. Torque and mechanomyogram relationships during electrically-evoked isometric quadriceps contractions in persons with spinal cord injury.

    PubMed

    Ibitoye, Morufu Olusola; Hamzaid, Nur Azah; Hasnan, Nazirah; Abdul Wahab, Ahmad Khairi; Islam, Md Anamul; Kean, Victor S P; Davis, Glen M

    2016-08-01

    The interaction between muscle contractions and joint loading produces torques necessary for movements during activities of daily living. However, during neuromuscular electrical stimulation (NMES)-evoked contractions in persons with spinal cord injury (SCI), a simple and reliable proxy of torque at the muscle level has been minimally investigated. Thus, the purpose of this study was to investigate the relationships between muscle mechanomyographic (MMG) characteristics and NMES-evoked isometric quadriceps torques in persons with motor complete SCI. Six SCI participants with lesion levels below C4 [(mean (SD) age, 39.2 (7.9) year; stature, 1.71 (0.05) m; and body mass, 69.3 (12.9) kg)] performed randomly ordered NMES-evoked isometric leg muscle contractions at 30°, 60° and 90° knee flexion angles on an isokinetic dynamometer. MMG signals were detected by an accelerometer-based vibromyographic sensor placed over the belly of rectus femoris muscle. The relationship between MMG root mean square (MMG-RMS) and NMES-evoked torque revealed a very high association (R(2)=0.91 at 30°; R(2)=0.98 at 60°; and R(2)=0.97 at 90° knee angles; P<0.001). MMG peak-to-peak (MMG-PTP) and stimulation intensity were less well related (R(2)=0.63 at 30°; R(2)=0.67 at 60°; and R(2)=0.45 at 90° knee angles), although were still significantly associated (P≤0.006). Test-retest interclass correlation coefficients (ICC) for the dependent variables ranged from 0.82 to 0.97 for NMES-evoked torque, between 0.65 and 0.79 for MMG-RMS, and from 0.67 to 0.73 for MMG-PTP. Their standard error of measurements (SEM) ranged between 10.1% and 31.6% (of mean values) for torque, MMG-RMS and MMG-PTP. The MMG peak frequency (MMG-PF) of 30Hz approximated the stimulation frequency, indicating NMES-evoked motor unit firing rate. The results demonstrated knee angle differences in the MMG-RMS versus NMES-isometric torque relationship, but a similar torque related pattern for MMG-PF. These findings suggested that MMG was well associated with torque production, reliably tracking the motor unit recruitment pattern during NMES-evoked muscle contractions. The strong positive relationship between MMG signal and NMES-evoked torque production suggested that the MMG might be deployed as a direct proxy for muscle torque or fatigue measurement during leg exercise and functional movements in the SCI population. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Effect of STS space suit on astronaut dominant upper limb EVA work performance

    NASA Technical Reports Server (NTRS)

    Greenisen, Michael C.

    1987-01-01

    The STS Space Suited and unsuited dominant upper limb performance was evaluated in order to quantify future EVA astronaut skeletal muscle upper limb performance expectations. Testing was performed with subjects standing in EVA STS foot restraints. Data was collected with a CYBEX Dynamometer enclosed in a waterproof container. Control data was taken in one g. During one g testing, weight of the Space Suit was relieved from the subject via an overhead crane with a special connection to the PLSS of the suit. Experimental data was acquired during simulated zero g, accomplished by neutral buoyancy in the Weightless Environment Training Facility. Unsuited subjects became neutrally buoyant via SCUBA BC vests. Actual zero g experimental data was collected during parabolic arc flights on board NASA's modified KC-135 aircraft. During all test conditions, subjects performed five EVA work tasks requiring dominant upper limb performance and ten individual joint articulation movements. Dynamometer velocities for each tested movement were 0 deg/sec, 30 or 60 deg/sec and 120 or 180 deg/sec, depending on the test, with three repetitions per test. Performance was measured in foot pounds of torque.

  9. Training Effectiveness of The Inertial Training and Measurement System

    PubMed Central

    Naczk, Mariusz; Brzenczek-Owczarzak, Wioletta; Arlet, Jarosław; Naczk, Alicja; Adach, Zdzisław

    2014-01-01

    The purpose of this study was to evaluate the efficacy of inertial training with different external loads using a new original device - the Inertial Training and Measurement System (ITMS). Forty-six physical education male students were tested. The participants were randomly divided into three training groups and a control group (C group). The training groups performed inertial training with three different loads three times weekly for four weeks. The T0 group used only the mass of the ITMS flywheel (19.4 kg), the T5 and T10 groups had an additional 5 and 10 kg on the flywheel, respectively. Each training session included three exercise sets involving the shoulder joint adductors. Before and after training, the maximal torque and power were measured on an isokinetic dynamometer during adduction of the shoulder joint. Simultaneously, the electromyography activity of the pectoralis major muscle was recorded. Results of the study indicate that ITMS training induced a significant increase in maximal muscle torque in the T0, T5, T10 groups (15.5%, 13.0%, and 14.0%, respectively). Moreover, ITMS training caused a significant increase in power in the T0, T5, T10 groups (16.6%, 19.5%, and 14.5%, respectively). The percentage changes in torque and power did not significantly differ between training groups. Electromyography activity of the pectoralis major muscle increased only in the T0 group after four weeks of training. Using the ITMS device in specific workouts allowed for an increase of shoulder joint adductors torque and power in physical education students. PMID:25713662

  10. Test-retest reliability of cardinal plane isokinetic hip torque and EMG.

    PubMed

    Claiborne, Tina L; Timmons, Mark K; Pincivero, Danny M

    2009-10-01

    The objective of the present study was to establish test-retest reliability of isokinetic hip torque and prime mover electromyogram (EMG) through the three cardinal planes of motion. Thirteen healthy young adults participated in two experimental sessions, separated by approximately one week. During each session, isokinetic hip torque was evaluated on the Biodex Isokinetic Dynamometer at a velocity of 60 deg/s. Subjects performed three maximal-effort concentric and eccentric contractions, separately, for right and left hip abduction/adduction, flexion/extension, and internal/external rotation. Surface EMGs were sampled from the gluteus maximus, gluteus medius, adductor, medial and lateral hamstring, and rectus femoris muscles during all contractions. Intraclass correlation coefficients (ICC - 2,1) and standard errors of measurement (SEM) were calculated for peak torque for each movement direction and contraction mode, while ICCs were only computed for the EMG data. Motions that demonstrated high torque reliability included concentric hip abduction (right and left), flexion (right and left), extension (right) and internal rotation (right and left), and eccentric hip abduction (left), adduction (left), flexion (right), and extension (right and left) (ICC range=0.81-0.91). Motions with moderate torque reliability included concentric hip adduction (right), extension (left), internal rotation (left), and external rotation (right), and eccentric hip abduction and adduction (right), flexion (left), internal rotation (right and left), and external rotation (right and left) (ICC range=0.49-0.79). The majority of the EMG sampled muscles (n=12 and n=11 for concentric and eccentric contractions, respectively) demonstrated high reliability (ICC=0.81-0.95). Instances of low, or unacceptable, EMG reliability values occurred for the medial hamstring muscle of the left leg (both contraction modes) and the adductor muscle of the right leg during eccentric internal rotation. The major finding revealed high and moderate levels of between-day reliability of isokinetic hip peak torque and prime mover EMG. It is recommended that the day-to-day variability estimates concomitant with acceptable levels of reliability be considered when attempting to objectify intervention effects on hip muscle performance.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, Yi; Keller, Jonathan; Zhang, Zhiwei

    The planetary load sharing characteristics of wind turbine gearboxes supported by cylindrical roller bearings (CRBs) and preloaded tapered roller bearings (TRBs) when subjected to rotor moments are compared in this work. Planetary bearing loads were measured in field-representative dynamometer tests and compared to loads predicted by finite-element models. Load sharing was significantly improved with preloaded TRBs. In pure torque conditions, the upwind planet bearing loads in the gearbox with preloaded TRBs were a maximum of 1.14 compared to 1.47 in the gearbox with CRBs. Consequently, the predicted fatigue life of the complete set of planetary bearings for the gearbox withmore » preloaded TRBs is 3.5 times greater than that of the gearbox with CRBs.« less

  12. Child–adult differences in the kinetics of torque development

    PubMed Central

    DOTAN, RAFFY; MITCHELL, CAMERON; COHEN, ROTEM; GABRIEL, DAVID; KLENTROU, PANAGIOTA; FALK, BAREKET

    2013-01-01

    Children have lower size-normalised maximal voluntary force, speed, and power than adults. It has been hypothesised that these and other age-related performance differences are due to lesser type-II motor-unit utilisation in children. This should be manifested as slower force kinetics in explosive muscle contractions. The purpose of this study was to investigate the nature of child–adult force-kinetics differences and whether the latter could support that hypothesis. Untrained boys (n = 20) and men (n = 20) (10.1 ± 1.3 and 22.9 ± 4.4 years, respectively), performed maximal, explosive, isometric elbow flexions and knee extensions on a Biodex dynamometer. Peak torque (MVC), times to 10–100% MVC, and other kinetics parameters were determined. The boys’ body-mass-normalised knee extension MVC, peak rate of torque development, and %MVC at 100 ms were 26, 17 and 23% lower compared with the men and their times to 30% and 80% MVC were 24 and 48% longer, respectively. Elbow flexion kinetics showed similar or greater differences. The findings illuminate boys’ inherent disadvantage in tasks requiring speed or explosive force. It is demonstrated that the extent of the boys–men kinetics disparity cannot be explained by muscle-composition and/or musculo-tendinous-stiffness differences. We suggest therefore that the findings indirectly support children’s lower utilisation of type-II motor units. PMID:23320937

  13. Isokinetic Leg Strength and Power in Elite Handball Players

    PubMed Central

    González-Ravé, José M.; Juárez, Daniel; Rubio-Arias, Jacobo A.; Clemente-Suarez, Vicente J; Martinez-Valencia, María A; Abian-Vicen, Javier

    2014-01-01

    Isokinetic strength evaluation of the knee flexion and extension in concentric mode of contraction is an important part of the comprehensive evaluation of athletes. The aims of this study were to evaluate the isokinetic knee peak torque in both the extension and flexion movement in the dominant and non-dominant leg, and the relationship with jumping performance. Twelve elite male handball players from the top Spanish handball division voluntary participated in the study (age 27.68 ± 4.12 years; body mass 92.89 ± 12.34 kg; body height 1.90 ± 0.05 m). The knee extensor and flexor muscle peak torque of each leg were concentrically measured at 60º/s and 180º/s with an isokinetic dynamometer. The Squat Jump and Countermovement Jump were performed on a force platform to determine power and vertical jump height. Non-significant differences were observed between legs in the isokinetic knee extension (dominant= 2.91 ± 0.53 Nm/kg vs non-dominant = 2.70 ± 0.47 Nm/kg at 60º/s; dominant = 1.90 ± 0.31 Nm/kg vs non-dominant = 1.83 ± 0.29 Nm/kg at 180º/s) and flexion peak torques (dominant = 1.76 ± 0.29 Nm/kg vs non-dominant = 1.72 ± 0.39 Nm/kg at 60º/s; dominant = 1.30 ± 0.23 Nm/kg vs non-dominant = 1.27 ± 0.35 Nm/kg at 180º/s). Low and non-significant correlation coefficients were found between the isokinetic peak torques and vertical jumping performance (SJ = 31.21 ± 4.32 cm; CMJ = 35.89 ± 4.20 cm). Similar isokinetic strength was observed between the legs; therefore, no relationship was found between the isokinetic knee flexion and extension peak torques as well as vertical jumping performance in elite handball players. PMID:25114749

  14. Isokinetic leg strength and power in elite handball players.

    PubMed

    González-Ravé, José M; Juárez, Daniel; Rubio-Arias, Jacobo A; Clemente-Suarez, Vicente J; Martinez-Valencia, María A; Abian-Vicen, Javier

    2014-06-28

    Isokinetic strength evaluation of the knee flexion and extension in concentric mode of contraction is an important part of the comprehensive evaluation of athletes. The aims of this study were to evaluate the isokinetic knee peak torque in both the extension and flexion movement in the dominant and non-dominant leg, and the relationship with jumping performance. Twelve elite male handball players from the top Spanish handball division voluntary participated in the study (age 27.68 ± 4.12 years; body mass 92.89 ± 12.34 kg; body height 1.90 ± 0.05 m). The knee extensor and flexor muscle peak torque of each leg were concentrically measured at 60º/s and 180º/s with an isokinetic dynamometer. The Squat Jump and Countermovement Jump were performed on a force platform to determine power and vertical jump height. Non-significant differences were observed between legs in the isokinetic knee extension (dominant= 2.91 ± 0.53 Nm/kg vs non-dominant = 2.70 ± 0.47 Nm/kg at 60º/s; dominant = 1.90 ± 0.31 Nm/kg vs non-dominant = 1.83 ± 0.29 Nm/kg at 180º/s) and flexion peak torques (dominant = 1.76 ± 0.29 Nm/kg vs non-dominant = 1.72 ± 0.39 Nm/kg at 60º/s; dominant = 1.30 ± 0.23 Nm/kg vs non-dominant = 1.27 ± 0.35 Nm/kg at 180º/s). Low and non-significant correlation coefficients were found between the isokinetic peak torques and vertical jumping performance (SJ = 31.21 ± 4.32 cm; CMJ = 35.89 ± 4.20 cm). Similar isokinetic strength was observed between the legs; therefore, no relationship was found between the isokinetic knee flexion and extension peak torques as well as vertical jumping performance in elite handball players.

  15. Humeral elevation reduces the dynamic control ratio of the shoulder muscles during internal rotation.

    PubMed

    Howard, William; Burgess, Jonathan; Vrhovnik, Borut; Stringer, Christian; Choy, Sherrie T; Marsden, Jonathan F; Gedikoglou, Ingrid A; Shum, Gary L

    2017-04-01

    To determine the differences in the dynamic control ratio of the glenohumeral joint rotators, during internal rotation at 20° and 60° of humeral elevation in the scapular plan. Dynamic control ratio (DCR) is defined as the ratio between eccentric action of the lateral rotators and the concentric action of the medial rotators. A cross-sectional laboratory study. Thirty asymptomatic participants (men n=14, women n=16, mean age=29.4±8.9years, BMI: 24.1±5.4) were tested. Peak torque generated by the concentric action of the MR and the eccentric action of the LR of the shoulder joint and the DCR were evaluated on the dominant arm using an isokinetic dynamometer at 20° and 60° of humeral elevation at a speed of 20°/s. There was a significant decrease in the DCR at 60° humeral elevation when compared to 20° humeral elevation (p<0.05). This decrease was due to the significant decrease in eccentric peak torques at 60° humeral elevation when compared to 20° (p<0.05). However, there was no significant difference in the concentric peak torques between 20° and 60° (p>0.05). The significant decrease in the DCR as a consequence of a decrease in the eccentric peak torque of the LR when the humerus is in a more elevated position suggests that the introduction of humeral elevation can be used as a progression for improving the eccentric action of the shoulder LR and subsequently the dynamic control of the shoulder. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  16. Test-retest reliability of biodex system 4 pro for isometric ankle-eversion and -inversion measurement.

    PubMed

    Tankevicius, Gediminas; Lankaite, Doanata; Krisciunas, Aleksandras

    2013-08-01

    The lack of knowledge about isometric ankle testing indicates the need for research in this area. to assess test-retest reliability and to determine the optimal position for isometric ankle-eversion and -inversion testing. Test-retest reliability study. Isometric ankle eversion and inversion were assessed in 3 different dynamometer foot-plate positions: 0°, 7°, and 14° of inversion. Two maximal repetitions were performed at each angle. Both limbs were tested (40 ankles in total). The test was performed 2 times with a period of 7 d between the tests. University hospital. The study was carried out on 20 healthy athletes with no history of ankle sprains. Reliability was assessed using intraclass correlation coefficient (ICC2,1); minimal detectable change (MDC) was calculated using a 95% confidence interval. Paired t test was used to measure statistically significant changes, and P <.05 was considered statistically significant. Eversion and inversion peak torques showed high ICCs in all 3 angles (ICC values .87-.96, MDC values 3.09-6.81 Nm). Eversion peak torque was the smallest when testing at the 0° angle and gradually increased, reaching maximum values at 14° angle. The increase of eversion peak torque was statistically significant at 7 ° and 14° of inversion. Inversion peak torque showed an opposite pattern-it was the smallest when measured at the 14° angle and increased at the other 2 angles; statistically significant changes were seen only between measures taken at 0° and 14°. Isometric eversion and inversion testing using the Biodex 4 Pro system is a reliable method. The authors suggest that the angle of 7° of inversion is the best for isometric eversion and inversion testing.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winterbone, D.E.; Richards, P.

    A microprocessor controlled test bed was built for steady state mapping of petrol engines using a sweep mapping technique. The addition of an electric motor to the fast acting dynamometer allowed rapid load changes to be applied at nominally constant speed. This made it possible to consider the dynamic behaviour of the power generation sub-system of the engine. The engine was initially subjected to ramp changes of torque but these did not give consistent results. PRBS signals were then used for the same variable and a mathematical transfer function model developed for the engine power system. The engine was consideredmore » both as a continuous and sample data system. Results will be presented which show fuel management has an appreciable effect on the engine dynamic response.« less

  18. The effect of angular velocity and cycle on the dissipative properties of the knee during passive cyclic stretching: a matter of viscosity or solid friction.

    PubMed

    Nordez, A; McNair, P J; Casari, P; Cornu, C

    2009-01-01

    The mechanisms behind changes in mechanical parameters following stretching are not understood clearly. This study assessed the effects of joint angular velocity on the immediate changes in passive musculo-articular properties induced by cyclic stretching allowing an appreciation of viscosity and friction, and their contribution to changes in torque that occur. Ten healthy subjects performed five passive knee extension/flexion cycles on a Biodex dynamometer at five preset angular velocities (5-120 deg/s). The passive torque and knee angle were measured, and the potential elastic energy stored during the loading and the dissipation coefficient were calculated. As the stretching velocity increased, so did stored elastic energy and the dissipation coefficient. The slope of the linear relationship between the dissipation coefficient and the angular velocity was unchanged across repetitions indicating that viscosity was unlikely to be affected. A difference in the y-intercept across repetitions 1 and 5 was indicative of a change in processes associated with solid friction. Electromyographical responses to stretching were low across all joint angular velocities. Torque changes during cyclic motion may primarily involve solid friction which is more indicative of rearrangement/slipping of collagen fibers rather than the redistribution of fluid and its constituents within the muscle. The findings also suggest that it is better to stretch slowly initially to reduce the amount of energy absorption required by tissues, but thereafter higher stretching speeds can be undertaken.

  19. Pain sensitivity and torque used during measurement predicts change in range of motion at the knee.

    PubMed

    Bishop, Mark D; George, Steven Z

    2017-01-01

    To determine the extent to which changes in knee range of motion (ROM) after a stretching program are related to sensory factors at the time of testing and the amount of force used during the measurement of ROM, rather than changes in soft-tissue properties. Randomized, single-blind design. Participants were randomly assigned to a control or stretching group. Research laboratory. Forty-four healthy volunteers (22.8±2.8 years of age; 23 men). The stretching group undertook static stretching twice a day for 8 weeks. The control group continued with routine activity, but was discouraged from starting a flexibility program. ROM and tissue extensibility was assessed using a Biodex3 dynamometer, and ratings of thermal pain were collected at baseline and at 4 and 8 weeks by an examiner blinded to group assignment. Multilevel modeling was used to examine predictors of ROM across time. The stretching group showed a 6% increase, and the control group had a 2% increase, in ROM over the 8-week program. However, when fixed and random effects were tested in a complete model, the group assignment was not significant. End-point torque during ROM testing ( p =0.021) and the ratings in response to thermal testing ( p <0.001) were significant, however. ROM measured in a testing session was not predicted by assignment to a stretching program. Rather, ROM was predicted by the ratings of thermal stimuli and the peak torque used to apply the stretch.

  20. Isokinetic strength differences between patients with primary reverse and total shoulder prostheses: muscle strength quantified with a dynamometer.

    PubMed

    Alta, Tjarco D W; Veeger, DirkJan H E J; de Toledo, Joelly M; Janssen, Thomas W J; Willems, W Jaap

    2014-11-01

    Range of motion after total shoulder arthroplasty is better than after reverse shoulder arthroplasty, however with similar clinical outcome. It is unclear if this difference can only be found in the different range of motion or also in the force generating capacity. (1) are isokinetically produced joint torques of reverse shoulder arthroplasty comparable to those of total shoulder arthroplasty? (2) Does this force-generating capacity correlate with functional outcome? Eighteen reverse shoulder arthroplasty patients (71years (SD 9years)) (21 shoulders, follow-up of 21months (SD 10months)) were recruited, 12 total shoulder arthroplasty patients (69years (SD 9years)) (14 shoulders, follow-up of 35months (SD 11months)). Pre- and post-operative Constant-Murley scores were obtained; two isokinetic protocols (ab-/adduction and ex-/internal rotations) at 60°/s were performed. Twelve of 18 reverse shoulder arthroplasty patients generated enough speed to perform the test (13 shoulders). Mean ab-/adduction torques are 16.3Nm (SD 5.6Nm) and 20.4Nm (SD 11.8Nm). All total shoulder arthroplasty patients generated enough speed (14 shoulders). Mean ab-/adduction torques are 32.1Nm (SD 13.3Nm) and 43.1Nm (SD 21.5Nm). Only 8 reverse shoulder arthroplasty patients (9 shoulders) could perform ex-/internal rotation tasks and all total shoulder arthroplasty patients. Mean ex-/internal rotation torques are 9.3Nm (SD 4.7Nm) and 9.2Nm (SD 2.1Nm) for reverse shoulder arthroplasty, and 17.9Nm (SD 7.7Nm) and 23.5Nm (SD 10.6Nm) for total shoulder arthroplasty. Significant correlations between sub-scores: activity, mobility and strength and external rotation torques for reverse shoulder arthroplasty. Moderate to strong correlation for sub-scores: strength in relation to abduction, adduction and internal rotation torques for total shoulder arthroplasty. Shoulders with a total shoulder arthroplasty are stronger. This can be explained by the absence of rotator cuff muscles and (probably) medialized center of rotation in reverse shoulder arthroplasty. The strong correlation between external rotation torques and post-operative Constant-Murley sub-scores demonstrates that external rotation is essential for good clinical functioning in reverse shoulder arthroplasty. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Lower limb strength in sports-active transtibial amputees.

    PubMed

    Nolan, Lee

    2009-09-01

    The aim of this study was to compare hip strength in sports-active transtibial (TT) amputees, sedentary TT amputees and sports-active non-amputees. Three 'active' (exercising recreationally at least three times per week) TT amputees, four 'inactive' or sedentary TT amputees and nine 'active' able-bodied persons (AB) underwent concentric and eccentric hip flexion and extension strength testing on both limbs on an isokinetic dynamometer at 60 and 120 degrees /s. Little strength asymmetry was noted between the limbs of the active TT amputees (8% and 14% at 60 and 120 degrees /s, respectively), their residual limb being slightly stronger. Inactive TT amputees demonstrated up to 49% strength asymmetry, their intact limb being the stronger. Active TT amputees demonstrated greater peak hip torques (Nm/kg) for all conditions and speeds compared to inactive TT amputees. Peak hip torques (Nm/kg), were greater in the active TT amputees' residual limb compared to AB. While inactive TT amputees and AB had similar flexion/extension ratios, active TT amputees exhibited a lower ratio indicating overdeveloped hip extensors with respect to their hip flexors. It is not known whether this is due to the demands of sport or exercise with a prosthetic limb, or remaining residual thigh atrophy.

  2. Performance evaluation of a dental handpiece in simulation of clinical finishing using a novel 2DOF in vitro apparatus.

    PubMed

    Yin, L; Song, X F; Qu, S F; Huang, T; Mei, J P; Yang, Z Y; Li, J

    2006-11-01

    This paper reports on the performance evaluation of a dental handpiece in simulation of clinical finishing using a novel two-degrees-of-freedom (2DOF) in vitro apparatus. The instrumented apparatus consisted of a two-dimensional computer-controlled coordinate worktable carrying a dental handpiece, a piezoelectric force dynamometer, and a high-speed data acquisition and signal conditioning system for simulating the clinical operations and monitoring the dental finishing processes. The performance of the dental handpiece was experimentally evaluated with respect to rotational speed, torque, and specific finishing energy under the applied clinical finishing conditions. The results show that the rotational speeds of the dental handpiece decreased by increasing either the depth of cut or the feed rate at a constant clinically applied air pressure and water flowrate. They also decreased when increasing both the tangential and normal finishing forces. The specific finishing energy decreased with an increase in either depth of cut or feed rate, while the finishing torque increased as either the depth of cut or the feed rate was increased. Implications of these results were to provide guidance for proper applications of dental handpieces in clinical practice.

  3. Experimental Performance Evaluation of a High Speed Permanent Magnet Synchronous Motor and Drive for a Flywheel Application at Different Frequencies

    NASA Technical Reports Server (NTRS)

    Nagorny, Aleksandr S.; Jansen, Ralph H.; Kankam, M. David

    2007-01-01

    This paper presents the results of an experimental performance characterization study of a high speed, permanent magnet motor/generator (M/G) and drive applied to a flywheel module. Unlike the conventional electric machine the flywheel M/G is not a separated unit; its stator and rotor are integrated into a flywheel assembly. The M/G rotor is mounted on a flywheel rotor, which is magnetically levitated and sealed within a vacuum chamber during the operation. Thus, it is not possible to test the M/G using direct load measurements with a dynamometer and torque transducer. Accordingly, a new in-situ testing method had to be developed. The paper describes a new flywheel M/G and drive performance evaluation technique, which allows the estimation of the losses, efficiency and power quality of the flywheel high speed permanent magnet M/G, while working in vacuum, over wide frequency and torque ranges. This method does not require any hardware modification nor any special addition to the test rig. This new measurement technique is useful for high-speed applications, when applying an external load is technically difficult.

  4. In-line rotating torque sensor with on-board amplifier

    DOEpatents

    Kronberg, James W.

    1990-01-01

    A rotating torque sensor apparatus and method for measuring small torques comprising a shaft, a platform having a circuit board and a first moment arm attached to the shaft, a rotatable wheel coaxial with the shaft and having a second moment arm spaced apart from the first moment arm with a load cell therebetween for generating an electric signal as the torque is applied to the shaft and transferred through the moment arms to the load cell. The electrical signal is conducted from the load cell to the circuit board for filtering and amplification before being extracted from the torque assembly through a slip ring.

  5. Test stand performance of a convertible engine for advanced V/STOL and rotorcraft propulsion

    NASA Technical Reports Server (NTRS)

    Mcardle, Jack G.

    1987-01-01

    A variable inlet guide vane (VIGV) convertible engine that could be used to power future high-speed V/STOL and rotorcraft was tested on an outdoor stand. The engine ran stably and smoothly in the turbofan, turboshaft, and dual (combined fan and shaft) power modes. In the turbofan mode with the VIGV open, fuel consumption was comparable to that of a conventional turbofan engine. In the turboshaft mode with the VIGV closed, fuel consumption was higher than that of present turboshaft engines because power was wasted in churning fan-tip air flow. In dynamic performance tests with a specially built digital engine control and using a waterbrake dynamometer for shaft load, the engine responded effectively to large steps in thrust command and shaft torque.

  6. Planetary Load Sharing in Three-Point Mounted Wind Turbine Gearboxes: A Design and Test Comparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keller, Jonathan; Guo, Yi; Zhang, Zhiwei

    This work compares the planetary load-sharing characteristics of wind turbine gearboxes supported by cylindrical roller bearings (CRBs) and preloaded tapered roller bearings (TRBs) when subjected to rotor moments. Planetary bearing loads were measured in field-representative dynamometer tests and compared to loads predicted by finite-element models. Preloaded TRBs significantly improved load sharing. In pure torque conditions, the upwind planet bearing load in the gearbox with preloaded TRBs was only 14% more than the assumed load compared to 47% more for the gearbox with CRBs. Consequently, the predicted fatigue life of the complete set of planetary bearings for the gearbox with preloadedmore » TRBs is 3.5 times greater than that of the gearbox with CRBs.« less

  7. Microactuator production via high aspect ratio, high edge acuity metal fabrication technology

    NASA Technical Reports Server (NTRS)

    Guckel, H.; Christenson, T. R.

    1993-01-01

    LIGA is a procession sequence which uses x-ray lithography on photoresist layers of several hundred micrometers to produce very high edge acuity photopolymer molds. These plastic molds can be converted to metal molds via electroplating of many different metals and alloys. The end results are high edge acuity metal parts with large structural heights. The LIGA process as originally described by W. Ehrfeld can be extended by adding a surface micromachining phase to produce precision metal parts which can be assembled to form three-dimensional micromechanisms. This process, SLIGA, has been used to fabricate a dynamometer on a chip. The instrument has been fully implemented and will be applied to tribology issues, speed-torque characterization of planar magnetic micromotors and a new family of sensors.

  8. Preliminary results of steady state characterization of near term electric vehicle breadboard propulsion system

    NASA Technical Reports Server (NTRS)

    Sargent, N. B.

    1980-01-01

    The steady state test results on a breadboard version of the General Electric Near Term Electric Vehicle (ETV-1) are discussed. The breadboard was built using exact duplicate vehicle propulsion system components with few exceptions. Full instrumentation was provided to measure individual component efficiencies. Tests were conducted on a 50 hp dynamometer in a road load simulator facility. Characterization of the propulsion system over the lower half of the speed-torque operating range has shown the system efficiency to be composed of a predominant motor loss plus a speed dependent transaxle loss. At the lower speeds with normal road loads the armature chopper loss is also a significant factor. At the conditions corresponding to a cycle for which the vehicle system was specifically designed, the efficiencies are near optimum.

  9. Test stand performance of a convertible engine for advanced V/STOL and rotorcraft propulsion

    NASA Technical Reports Server (NTRS)

    Mcardle, Jack G.

    1988-01-01

    A variable inlet guide vane (VIGV) convertible engine that could be used to power future high-speed V/STOL and rotorcraft was tested on an outdoor stand. The engine ran stably and smoothly in the turbofan, turboshaft, and dual (combined fan and shaft) power modes. In the turbofan mode with the VIGV open, fuel consumption was comparable to that of a conventional turbofan engine. In the turboshaft mode with the VIGV closed, fuel consumption was higher than that of present turboshaft engines because power was wasted in churning fan-tip air flow. In dynamic performance tests with a specially built digital engine control and using a waterbrake dynamometer for shaft load, the engine responded effectively to large steps in thrust command and shaft torque.

  10. Further validation of artificial neural network-based emissions simulation models for conventional and hybrid electric vehicles.

    PubMed

    Tóth-Nagy, Csaba; Conley, John J; Jarrett, Ronald P; Clark, Nigel N

    2006-07-01

    With the advent of hybrid electric vehicles, computer-based vehicle simulation becomes more useful to the engineer and designer trying to optimize the complex combination of control strategy, power plant, drive train, vehicle, and driving conditions. With the desire to incorporate emissions as a design criterion, researchers at West Virginia University have developed artificial neural network (ANN) models for predicting emissions from heavy-duty vehicles. The ANN models were trained on engine and exhaust emissions data collected from transient dynamometer tests of heavy-duty diesel engines then used to predict emissions based on engine speed and torque data from simulated operation of a tractor truck and hybrid electric bus. Simulated vehicle operation was performed with the ADVISOR software package. Predicted emissions (carbon dioxide [CO2] and oxides of nitrogen [NO(x)]) were then compared with actual emissions data collected from chassis dynamometer tests of similar vehicles. This paper expands on previous research to include different driving cycles for the hybrid electric bus and varying weights of the conventional truck. Results showed that different hybrid control strategies had a significant effect on engine behavior (and, thus, emissions) and may affect emissions during different driving cycles. The ANN models underpredicted emissions of CO2 and NO(x) in the case of a class-8 truck but were more accurate as the truck weight increased.

  11. Shoulder Rotator Muscle Dynamometry Characteristics: Side Asymmetry and Correlations with Ball-Throwing Speed in Adolescent Handball Players

    PubMed Central

    Pontaga, Inese; Zidens, Janis

    2014-01-01

    The aim of the investigation was to: 1) compare shoulder external/internal rotator muscles’ peak torques and average power values and their ratios in the dominant and non-dominant arm; 2) determine correlations between shoulder rotator muscles’ peak torques, average power and ball-throwing speed in handball players. Fourteen 14 to 15-year-old male athletes with injury-free shoulders participated in the study (body height: 176 ± 7 cm, body mass 63 ± 9 kg). The tests were carried out by an isokinetic dynamometer system in the shoulder internal and external rotation movements at angular velocities of 60°/s, 90°/s and 240°/s during concentric contractions. The eccentric external– concentric internal rotator muscle contractions were performed at the velocity of 90°/s. The player threw a ball at maximal speed keeping both feet on the floor. The speed was recorded with reflected light rays. Training in handball does not cause significant side asymmetry in shoulder external/internal rotator muscle peak torques or the average power ratio. Positive correlations between isokinetic characteristics of the shoulder internal and external rotator muscles and ball-throwing speed were determined. The power produced by internal rotator muscles during concentric contractions after eccentric contractions of external rotator muscles was significantly greater in the dominant than in the non-dominant arm. Thus, it may be concluded that the shoulder eccentric external/concentric internal rotator muscle power ratio is significantly greater than this ratio in the concentric contractions of these muscles. PMID:25414738

  12. Isokinetic Evaluation of the Hip Flexor and Extensor Muscles: A Systematic Review.

    PubMed

    Zapparoli, Fabricio Yuri; Riberto, Marcelo

    2017-11-01

    Isokinetic dynamometry testing is a safe and reliable method accepted as the "gold standard" in the evaluation of muscle strength in the open kinetic chain. Isokinetic hip examinations face problems in the standardization of the position of the equipment axis, in the individual being examined, and in the adjustment of the lever arm and in stabilization strategies for the patients during the tests. Identification of the methodologic procedures with best reproducibility is also needed. To review the literature to evaluate the parameters used for the isokinetic evaluation of the hip flexor and extensor muscles and its reproducibility. This is a systematic literature review of the Cochrane, LILACS, PEDro, PubMed, and SciELO databases. The inclusion criteria were articles on the evaluation of hip flexor and/or extensor muscular strength with an isokinetic dynamometer and articles that analyzed the ICC or Pearson's reproducibility. The information extracted was positioning of the patient; positioning of the dynamometer axis; positioning of the lever arm; angular speed; sample size, pathology; type of contraction; and ICC and Pearson's results. 204 articles were found, from which 14 were selected that evaluated hip flexor and extensor muscles, involving 550 individuals who were submitted to an isokinetic hip evaluation. Five articles obtained the best result in reproducibility and had their methodology analyzed. To obtain better reproducibility of the isokinetic evaluation of the hip flexor and extensor muscles, the following recommendations must be followed: the individual must be positioned in the supine position and the dynamometer axis must be aligned with the greater trochanter of the femur. The positioning of the lever arm must be in the most distal region of the thigh possible. The angular speed used to analyze torque peak and muscle work was 60°/s, and to evaluate the muscle power it was 180°/s, with concentric and eccentric contractions being analyzed.

  13. Recovery Kinetics of Knee Flexor and Extensor Strength after a Football Match

    PubMed Central

    Draganidis, Dimitrios; Chatzinikolaou, Athanasios; Avloniti, Alexandra; Barbero-Álvarez, José C.; Mohr, Magni; Malliou, Paraskevi; Gourgoulis, Vassilios; Deli, Chariklia K.; Douroudos, Ioannis I.; Margonis, Konstantinos; Gioftsidou, Asimenia; Fouris, Andreas D.; Jamurtas, Athanasios Z.; Koutedakis, Yiannis; Fatouros, Ioannis G.

    2015-01-01

    We examined the temporal changes of isokinetic strength performance of knee flexor (KF) and extensor (KE) strength after a football match. Players were randomly assigned to a control (N = 14, participated only in measurements and practices) or an experimental group (N = 20, participated also in a football match). Participants trained daily during the two days after the match. Match and training overload was monitored with GPS devices. Venous blood was sampled and muscle damage was assessed pre-match, post-match and at 12h, 36h and 60h post-match. Isometric strength as well as eccentric and concentric peak torque of knee flexors and extensors in both limbs (dominant and non-dominant) were measured on an isokinetic dynamometer at baseline and at 12h, 36h and 60h after the match. Functional (KFecc/KEcon) and conventional (KFcon/KEcon) ratios were then calculated. Only eccentric peak torque of knee flexors declined at 60h after the match in the control group. In the experimental group: a) isometric strength of knee extensors and knee flexors declined (P<0.05) at 12h (both limbs) and 36h (dominant limb only), b) eccentric and concentric peak torque of knee extensors and flexors declined (P<0.05) in both limbs for 36h at 60°/s and for 60h at 180°/s with eccentric peak torque of knee flexors demonstrating a greater (P<0.05) reduction than concentric peak torque, c) strength deterioration was greater (P<0.05) at 180°/s and in dominant limb, d) the functional ratio was more sensitive to match-induced fatigue demonstrating a more prolonged decline. Discriminant and regression analysis revealed that strength deterioration and recovery may be related to the amount of eccentric actions performed during the match and athletes' football-specific conditioning. Our data suggest that recovery kinetics of knee flexor and extensor strength after a football match demonstrate strength, limb and velocity specificity and may depend on match physical overload and players' physical conditioning level. PMID:26043222

  14. Cross-Cultural Adaptation and Validation of the Spanish-Language Version of the SARC-F to Assess Sarcopenia in Mexican Community-Dwelling Older Adults.

    PubMed

    Parra-Rodríguez, Lorena; Szlejf, Claudia; García-González, Ana Isabel; Malmstrom, Theodore K; Cruz-Arenas, Esteban; Rosas-Carrasco, Oscar

    2016-12-01

    To cross-culturally adapt and validate the Spanish-language version of the SARC-F in Mexican community-dwelling older adults. Cross-sectional analysis of a prospective cohort. The FraDySMex study, a 2-round evaluation of community-dwelling adults from 2 municipalities in Mexico City. Participants were 487 men and women older than 60 years, living in the designated area in Mexico City. Information from questionnaires regarding demographic characteristics, comorbidities, mental status, nutritional status, dependence in activities of daily living, frailty, and quality of life. Objective measurements of muscle mass, strength and function were as follows: skeletal muscle mass index (SMI) was taken using dual-energy x-ray, grip strength using a hand dynamometer, 6-meter gait speed using a GAIT Rite instrumented walkway, peak torque and power for knee extension using a isokinetic dynamometer, lower extremity functioning measured by the Short Physical Performance Battery (SPPB), and balance using evaluation on a foam surface, with closed eyes, in the Modified Clinical Test of Sensory Integration. The SARC-F scale translated to Spanish and the consensus panels' criteria from European, international, and Asian sarcopenia working groups were applied to evaluate sarcopenia. The Spanish language version of the SARC-F scale showed reliability (Cronbach alfa = 0.641. All items in the scale correlated to the scale's total score, rho = 0.43 to 0.76), temporal consistency evaluated by test-retest (CCI = 0.80), criterion validity when compared to the consensus panels' criteria (high specificity and negative predictive values). The scale was also correlated to other measures related to sarcopenia (such as age, quality of life, self-rated health status, cognition, dependence in activities of daily living, nutritional status, depression, gait speed, grip strength, peak torque and power for knee extension, SPPB, balance, SMI, and frailty). The SARC-F scale was successfully adapted to Spanish language and validated in community-dwelling Mexican older adults. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  15. Resistance exercise prevents plantar flexor deconditioning during bed rest

    NASA Technical Reports Server (NTRS)

    Bamman, M. M.; Hunter, G. R.; Stevens, B. R.; Guilliams, M. E.; Greenisen, M. C.

    1997-01-01

    Because resistance exercise (REX) and unloading induce opposing neuromuscular adaptations, we tested the efficacy of REX against the effects of 14 d of bed rest unloading (BRU) on the plantar flexor muscle group. Sixteen men were randomly assigned to no exercise (NOE, N = 8) or REX (N = 8). REX performed 5 sets x 6-10 repetitions to failure of constant resistance concentric/eccentric plantar flexion every other day during BRU. One-repetition maximum (1RM) strength was tested on the training device. The angle-specific torque-velocity relationship across 5 velocities (0, 0.52, 1.05, 1.75, and 2.97 rad.s-1) and the full range-of-motion power-velocity relationship were assessed on a dynamometer. Torque-position analyses identified strength changes at shortened, neutral, and stretched muscle lengths. Concentric and eccentric contractile work were measured across ten repetitions at 1.05 rad.s-1. Maximal neural activation was measured by surface electromyography (EMG). 1RM decreased 9% in NOE and improved 11% in REX (P < 0.05). Concentric (0.52 and 1.05 rad.s-1), eccentric (0.52 and 2.97 rad.s-1), and isometric angle-specific torques decreased (P < 0.05) in NOE, averaging 18%, 17%, and 13%, respectively. Power dropped (P < 0.05) in NOE at three eccentric (21%) and two concentric (14%) velocities. REX protected angle-specific torque and average power at all velocities. Concentric and eccentric strength decreased at stretched (16%) and neutral (17%) muscle lengths (P < 0.05) in NOE while REX maintained or improved strength at all joint positions. Concentric (15%) and eccentric (11%) contractile work fell in NOE (P < 0.05) but not in REX. Maximal plantar flexor EMG did not change in either group. In summary, constant resistance concentric/eccentric REX completely prevented plantar flexor performance deconditioning induced by BRU. The reported benefits of REX should prove useful in prescribing exercise for astronauts in microgravity and for patients susceptible to functional decline during bed- or chair-bound hospital stays.

  16. Characterization of the High-Speed-Stage Bearing Skidding of Wind Turbine Gearboxes Induced by Dynamic Electricity Grid Events

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helsen, Jan; Guillaume, Patrick; Guo, Yi

    Bearing behavior is an important factor for wind turbine drivetrain reliability. Extreme loads and dynamic excitations pose challenges to the bearing design and therefore its performance. Excessive skidding of the bearing rollers should be avoided because it can cause scuffing failures. Excitations coming from wind and the electricity grid can subject the drivetrain to fluctuating torque and nontorque loads. Wind-induced excitations have been investigated predominantly in literature. However, modern wind turbines are subjected more and more to grid-induced loads because of stricter electricity grid regulations. For example, during fault-ride-through events, turbines are required to stay connected for a longer periodmore » of time during the grid failure. This work investigates the influence of electrically induced excitations on the skidding behaviour of the tapered roller bearings on the high-speed stage of a wind turbine gearbox. This skidding behaviour during dynamic events is described as a potential bearing failure initiator by many researchers; however, only limited full-scale dynamic testing is documented. Therefore, a dedicated gridloss-type event is defined in the paper and conducted in a dynamometer test on a full-scale wind turbine nacelle. During the event, a complete electricity grid failure is simulated while the turbine is at rated speed and predefined torque levels. Particular focus is on the characterization of the high-speed shaft tapered roller bearing slip behavior. Strain-gauge bridges in grooves along the circumference of the outer ring are used to characterize the bearing load zone in detail. It is shown that during the torque reversals of the transient event, roller slip can be induced. This indicates the potential of the applied load case to go beyond the preload of the tapered roller bearing. Furthermore, the relation between the applied torque and skidding level is studied.« less

  17. Characterization of the High-Speed-Stage Bearing Skidding of Wind Turbine Gearboxes Induced by Dynamic Electricity Grid Events: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helsen, Jan; Guillaume, Patrick; Guo, Yi

    Bearing behavior is an important factor for wind turbine drivetrain reliability. Extreme loads and dynamic excitations pose challenges to the bearing design and therefore its performance. Excessive skidding of the bearing rollers should be avoided because it can cause scuffing failures. Excitations coming from wind and the electricity grid can subject the drivetrain to fluctuating torque and nontorque loads. Wind-induced excitations have been investigated predominantly in literature. However, modern wind turbines are subjected more and more to grid-induced loads because of stricter electricity grid regulations. For example, during fault-ride-through events, turbines are required to stay connected for a longer periodmore » of time during the grid failure. This work investigates the influence of electrically induced excitations on the skidding behaviour of the tapered roller bearings on the high-speed stage of a wind turbine gearbox. This skidding behaviour during dynamic events is described as a potential bearing failure initiator by many researchers; however, only limited full-scale dynamic testing is documented. Therefore, a dedicated gridloss-type event is defined in the paper and conducted in a dynamometer test on a full-scale wind turbine nacelle. During the event, a complete electricity grid failure is simulated while the turbine is at rated speed and predefined torque levels. Particular focus is on the characterization of the high-speed shaft tapered roller bearing slip behavior. Strain-gauge bridges in grooves along the circumference of the outer ring are used to characterize the bearing load zone in detail. It is shown that during the torque reversals of the transient event, roller slip can be induced. This indicates the potential of the applied load case to go beyond the preload of the tapered roller bearing. Furthermore, the relation between the applied torque and skidding level is studied.« less

  18. EMGD-FE: an open source graphical user interface for estimating isometric muscle forces in the lower limb using an EMG-driven model

    PubMed Central

    2014-01-01

    Background This paper describes the “EMG Driven Force Estimator (EMGD-FE)”, a Matlab® graphical user interface (GUI) application that estimates skeletal muscle forces from electromyography (EMG) signals. Muscle forces are obtained by numerically integrating a system of ordinary differential equations (ODEs) that simulates Hill-type muscle dynamics and that utilises EMG signals as input. In the current version, the GUI can estimate the forces of lower limb muscles executing isometric contractions. Muscles from other parts of the body can be tested as well, although no default values for model parameters are provided. To achieve accurate evaluations, EMG collection is performed simultaneously with torque measurement from a dynamometer. The computer application guides the user, step-by-step, to pre-process the raw EMG signals, create inputs for the muscle model, numerically integrate the ODEs and analyse the results. Results An example of the application’s functions is presented using the quadriceps femoris muscle. Individual muscle force estimations for the four components as well the knee isometric torque are shown. Conclusions The proposed GUI can estimate individual muscle forces from EMG signals of skeletal muscles. The estimation accuracy depends on several factors, including signal collection and modelling hypothesis issues. PMID:24708668

  19. [Isokinetic profile of knee flexors and extensors in a population of rugby players].

    PubMed

    Larrat, E; Kemoun, G; Carette, P; Teffaha, D; Dugue, B

    2007-06-01

    We aimed to assess the isokinetic profile of the flexor and extensor muscles of the knee within a population of rugby players. This was a descriptive study. The rugby players underwent bilateral isokinetic assessment of knee flexion and extension on a CON-TREX MJ isokinetic dynamometer functioning at four angular frequencies - 90, 120, 180 and 240 degrees/s - in a concentric manner. The isokinetic parameters were peak torque, mean power, and mean work in relation to weight and femoral bicep: quadriceps ratio. The population included 16 "Federal 1" (semi-professional) rugby players with mean age 25 years (range 20-33 years). The players were divided into two groups: "forward" players (props, hookers, second line, third line) and "back" players (scrum, inside, center, wing, tail). The values of the isokinetic parameters did not reveal use of a preferred limb. Consequently, peak torque and mean power were higher in forward players than back players, whereas back players showed a higher relative power throughout the isokinetic test. Among rugby players, forward and back players showed differences in several isokinetic parameters. Accurate knowledge of the equilibrium between the knee's effector muscles is important for stability of the joint, to not only minimize articular accidents but also pinpoint force imbalances, thereby preventing muscular lesions during the sports season.

  20. EMGD-FE: an open source graphical user interface for estimating isometric muscle forces in the lower limb using an EMG-driven model.

    PubMed

    Menegaldo, Luciano Luporini; de Oliveira, Liliam Fernandes; Minato, Kin K

    2014-04-04

    This paper describes the "EMG Driven Force Estimator (EMGD-FE)", a Matlab® graphical user interface (GUI) application that estimates skeletal muscle forces from electromyography (EMG) signals. Muscle forces are obtained by numerically integrating a system of ordinary differential equations (ODEs) that simulates Hill-type muscle dynamics and that utilises EMG signals as input. In the current version, the GUI can estimate the forces of lower limb muscles executing isometric contractions. Muscles from other parts of the body can be tested as well, although no default values for model parameters are provided. To achieve accurate evaluations, EMG collection is performed simultaneously with torque measurement from a dynamometer. The computer application guides the user, step-by-step, to pre-process the raw EMG signals, create inputs for the muscle model, numerically integrate the ODEs and analyse the results. An example of the application's functions is presented using the quadriceps femoris muscle. Individual muscle force estimations for the four components as well the knee isometric torque are shown. The proposed GUI can estimate individual muscle forces from EMG signals of skeletal muscles. The estimation accuracy depends on several factors, including signal collection and modelling hypothesis issues.

  1. Shortening-induced torque depression in old men: implications for age-related power loss.

    PubMed

    Power, Geoffrey A; Makrakos, Demetri P; Stevens, Daniel E; Herzog, Walter; Rice, Charles L; Vandervoort, Anthony A

    2014-09-01

    Following active muscle shortening, the steady-state isometric torque at the final muscle length is lower than the steady-state torque obtained for a purely isometric contraction at that same final muscle length. This well-documented property of skeletal muscle is termed shortening-induced torque depression (TD). Despite many investigations into the mechanisms of weakness and power loss in old age, the influence of muscle shortening on the history dependence of isometric torque production remains to be elucidated. Thus, it is unclear whether older adults are disadvantaged for torque and power production following a dynamic shortening contraction. The purpose of this study was to evaluate shortening-induced TD in older adults, and to determine whether shortening-induced TD is related to power loss. Maximal voluntary isometric dorsiflexion contractions (MVC; 10s) in 8 young (25.5±3.7years) and 9 old (76.1±5.4years) men were performed on a HUMAC NORM dynamometer as a reference, and then again following an active shortening of 40° joint excursion (40°PF-0°PF) at angular velocities of 15°/s and 120°/s. Work and instantaneous power were derived during shortening. Shortening-induced TD was calculated and expressed as a percentage by determining the mean torque value over 1s during the isometric steady state of the MVC following shortening, divided by the mean torque value for the same 1s time period during the isometric reference MVC. To assess muscle activation, electromyography (root mean square; EMGRMS) of the tibialis anterior (TA) and soleus (SOL) was calculated at identical time points used in assessing shortening-induced TD, and voluntary activation (VA) was assessed using the interpolated twitch technique. Old were 18% weaker than young for MVC, and ~40% less powerful for 15°/s and 120°/s of shortening. Old produced 37% and 21% less work for 15°/s and 120°/s than young, respectively. Furthermore, old experienced 60% and 70% greater shortening-induced TD than young for 15°/s and 120°/s, respectively with similar EMGRMS and VA across all conditions. A significant relationship between shortening-induced TD and instantaneous power was found only at the fast angular velocity for both the old (R(2)=0.32) and young (R(2)=0.45) men. The older men experienced greater shortening-induced TD than young while maintaining similar levels of voluntary activation. This previously unaccounted for history-dependent property of muscle may provide insight into power loss in old age. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. 40 CFR 86.542-90 - Records required.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... dynamometer serial number, a reference to a vehicle test cell number may be used, with the advance approval of the Administrator, provided the test cell records show the pertinent instrument information. (h) All..., a reference to a vehicle test cell number may be used, with the advance approval of the...

  3. Can therapeutic Thai massage improve upper limb muscle strength in Parkinson's disease? An objective randomized-controlled trial.

    PubMed

    Miyahara, Yuka; Jitkritsadakul, Onanong; Sringean, Jirada; Aungkab, Nicharee; Khongprasert, Surasa; Bhidayasiri, Roongroj

    2018-04-01

    Muscle weakness is a frequent complaint amongst Parkinson's disease (PD) patients. However, evidence-based therapeutic options for this symptom are limited. We objectively measure the efficacy of therapeutic Thai massage (TTM) on upper limb muscle strength, using an isokinetic dynamometer. A total of 60 PD patients with muscle weakness that is not related to their 'off' periods or other neurological causes were equally randomized to TTM intervention (n = 30), consisting of six TTM sessions over a 3-week period, or standard medical care (no intervention, n = 30). Primary outcomes included peak extension and flexion torques. Scale-based outcomes, including Unified Parkinson's Disease Rating Scale (UPDRS) and visual analogue scale for pain (VAS) were also performed. From baseline to end of treatment, patients in the intervention group showed significant improvement on primary objective outcomes, including peak flexion torque (F = 30.613, p  < .001) and peak extension torque (F = 35.569, p  < .001) and time to maximal flexion speed (F = 14.216, p  = .001). Scale-based assessments mirrored improvements in the objective outcomes with a significant improvement from baseline to end of treatment of the UPDRS-bradykinesia of a more affected upper limb (F = 9.239, p  = .005), and VAS (F = 69.864, p  < .001) following the TTM intervention, compared to the control group. No patients reported adverse events in association with TTM. Our findings provide objective evidence that TTM used in combination with standard medical therapies is effective in improving upper limb muscle strength in patients with PD. Further studies are needed to determine the efficacy of TTM on other motor and non-motor symptoms in PD.

  4. Acute effects of constant torque and constant angle stretching on the muscle and tendon tissue properties.

    PubMed

    Konrad, Andreas; Budini, Francesco; Tilp, Markus

    2017-08-01

    Static stretching induces acute structural changes of the muscle-tendon unit (MTU) that are related to the intensity or duration of stretching. It has been reported that stretching with a constant torque (CT) leads to greater joint range of motion changes than stretching with a constant angle (CA). Whether or not this difference is due to different structural changes of the MTUs of the lower leg and ankle plantar flexors is not known. Therefore, the purpose of this study was to compare the acute effects of single CA and CT stretching on various muscle and tendon mechanical properties. Seventeen young, healthy volunteers were tested on two separate days using either CT or CA stretching (4 × 30 s each). Before and after stretching, dorsiflexion range of motion (RoM), passive resistive torque (PRT), and maximum voluntary contraction (MVC) were measured with a dynamometer. Ultrasonography of the medial gastrocnemius (GM) muscle-tendon junction (MTJ) displacement allowed us to determine the length changes in the tendon and muscle, respectively, and hence to calculate their stiffness. Maximum dorsiflexion increased while PRT, muscle-tendon stiffness, and muscle stiffness decreased following both CA and CT stretching. There was a greater increase in RoM following CT stretching compared to CA stretching. Moreover, the decline in PRT was greater during CT stretching compared to CA stretching. As expected, several functional adaptations (RoM, PRT) were different between CT and CA stretching due to the higher intensity of CT stretching. However, no structural differences in the adaptations to the stretching modalities could be detected. We suggest that the different functional adaptations between CA and CT stretching are the consequence of different adaptations in the perception of stretch and pain.

  5. Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility.

    PubMed

    Dirnberger, Johannes; Wiesinger, Hans-Peter; Wiemer, Nicolas; Kösters, Alexander; Müller, Erich

    2016-04-01

    The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48-72 h. The intraclass correlation coefficient (ICC 2,1) and the coefficient of variation (CV) were calculated for (i) maximum torque (MVC), (ii) the peak rate of torque development (RTD peak ) as well as for (iii) the average rate of torque development (RTD) and the impulse taken at several predefined time intervals (0-30 to 0-300 ms); thereby explosive strength variables were derived in two conceptually different versions: on the one hand from the MVC-trial (version I), on the other hand from the trial showing the RTD peak (version II). High ICC-values (0.80-0.99) and acceptable CV-values (1.9-8.7%) could be found for MVC as well as for the RTD and the impulse taken at time intervals of ≥100 ms, regardless of whether version I or II was used. In contrast, measurements of the RTD peak as well as the RTD and the impulse taken during the very early contraction phase (i.e. RTD/impulse 0-30ms and RTD/impulse 0-50ms ) showed clearly weaker reproducibility results (ICC: 0.53-0.84; CV: 7.3-16.4%) and gave rise to considerable doubts as to clinical usefulness, especially when derived using version I. However, if there is a need to measure explosive strength for earlier time intervals in practice, it is, in view of stronger reproducibility results, recommended to concentrate on measures derived from version II, which is based on the RTD peak -trial.

  6. Experimental Characterization of a Grid-Loss Event on a 2.5-MW Dynamometer Using Advanced Operational Modal Analysis: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helsen, J.; Weijtjens, W.; Guo, Y.

    2015-02-01

    This paper experimentally investigates a worst case grid loss event conducted on the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) drivetrain mounted on the 2.5MW NREL dynamic nacelle test-rig. The GRC drivetrain has a directly grid-coupled, fixed speed asynchronous generator. The main goal is the assessment of the dynamic content driving this particular assess the dynamic content of the high-speed stage of the GRC gearbox. In addition to external accelerometers, high frequency sampled measurements of strain gauges were used to assess torque fluctuations and bending moments both at the nacelle main shaft and gearbox high-speed shaft (HSS) throughmore » the entire duration of the event. Modal analysis was conducted using a polyreference Least Squares Complex Frequency-domain (pLSCF) modal identification estimator. The event driving the torsional resonance was identified. Moreover, the pLSCF estimator identified main drivetrain resonances based on a combination of acceleration and strain measurements. Without external action during the grid-loss event, a mode shape characterized by counter phase rotation of the rotor and generator rotor determined by the drivetrain flexibility and rotor inertias was the main driver of the event. This behavior resulted in significant torque oscillations with large amplitude negative torque periods. Based on tooth strain measurements of the HSS pinion, this work showed that at each zero-crossing, the teeth lost contact and came into contact with the backside flank. In addition, dynamic nontorque loads between the gearbox and generator at the HSS played an important role, as indicated by strain gauge-measurements.« less

  7. Acute effect of constant torque and angle stretching on range of motion, muscle passive properties, and stretch discomfort perception.

    PubMed

    Cabido, Christian E T; Bergamini, Juliana C; Andrade, André G P; Lima, Fernando V; Menzel, Hans J; Chagas, Mauro H

    2014-04-01

    The aim of the present study was to compare the acute effects of constant torque (CT) and constant angle (CA) stretching exercises on the maximum range of motion (ROMmax), passive stiffness (PS), and ROM corresponding to the first sensation of tightness in the posterior thigh (FSTROM). Twenty-three sedentary men (age, 19-33 years) went through 1 familiarization session and afterward proceeded randomly to both CA and CT treatment stretching conditions, on separate days. An isokinetic dynamometer was used to analyze hamstring muscles during passive knee extension. The subjects performed 4 stretches of 30 seconds each with a 15-second interval between them. In the CA stretching, the subject reached a certain ROM (95% of ROMmax), and the angle was kept constant. However, in the CT stretching exercise, the volunteer reached a certain resistance torque (corresponding to 95% of ROMmax) and it was kept constant. The results showed an increase in ROMmax for both CA and CT (p < 0.001), but the increase was greater for CT than for CA (CA vs. CT in poststretching, p = 0.002). Although the PS decreased for both CA and CT (p < 0.001), the decrease was greater for CT than for CA (CA vs. CT in poststretching, p = 0.002). The FSTROM increased for both CA and CT, but the increase for CT was greater than that for CA (CA vs. CT in poststretching, p = 0.003). The greater increase in ROMmax for the CT stretch may be explained by greater changes in the biomechanical properties of the muscle-tendon unit and stretch tolerance, as indicated by the results of PS and FSTROM.

  8. The Bigger the Hand, the Bigger the Difference? Implications for Testing Strength With Two Popular Handgrip Dynamometers.

    PubMed

    Abe, Takashi; Loenneke, Jeremy P; Thiebaud, Robert S; Loftin, Mark

    2017-10-16

    Studies developed the frail elderly handgrip strength (HGS) diagnostic criteria using multiple types of handgrip dynamometers. If different handgrip dynamometer report different values, then this would have the potential to misclassify people into the wrong diagnostic category. To examine the characteristics of HGS measured by two standard handgrip dynamometers, and to investigate the influence of hand size on HGS. University research laboratory. 87 young and middle-aged adults aged 20-60 years participated in this study. Standard methods of HGS measurements were used for hydraulic and Smedley's spring-type dynamometer, although the participants were instructed to maintain an upright standing position in both tests. Test-retest reliability of hydraulic and Smedley dynamometers provided comparable results to that observed with previous studies. However, the difference in HGS between the two dynamometers (Hydraulic-Smedley difference) was positively associated (r = 0.670, p < 0.001) with the mean of the two dynamometers. The participants who had relatively low HGS (at least <35 kg) produced similar HGS values when the two dynamometers were compared, while persons who had relatively higher HGS (at least >45 kg) produced greater strength values with the hydraulic compared to the Smedley. The hand and palm lengths were weakly correlated (r = 0.349 and r = 0.358, respectively, both p < 0.001) to the difference in HGS between the two dynamometers. Test-retest reliability of hydraulic and Smedley dynamometers provides comparable results to previous studies. However, the difference in HGS between the two dynamometers was positively associated with the mean of the two dynamometers. This Hydraulic-Smedley difference would not affect persons who have relatively low HGS (at least < 35 kg), while when HGS is relatively high, the comparison between dynamometers should be done with caution.

  9. The flagellar motor of Caulobacter crescentus generates more torque when a cell swims backward

    PubMed Central

    Lele, Pushkar P.; Roland, Thibault; Shrivastava, Abhishek; Chen, Yihao; Berg, Howard C.

    2016-01-01

    Caulobacter crescentus, a monotrichous bacterium, swims by rotating a single right-handed helical filament. CW motor rotation thrusts the cell forward 1, a mode of motility known as the pusher mode; CCW motor rotation pulls the cell backward, a mode of motility referred to as the puller mode 2. The situation is opposite in E. coli, a peritrichous bacterium, where CCW rotation of multiple left-handed filaments drives the cell forward. The flagellar motor in E. coli generates more torque in the CCW direction than the CW direction in swimming cells 3,4. However, monotrichous bacteria including C. crescentus swim forward and backward at similar speeds, prompting the assumption that motor torques in the two modes are the same 5,6. Here, we present evidence that motors in C. crescentus develop higher torques in the puller mode than in the pusher mode, and suggest that the anisotropy in torque-generation is similar in two species, despite the differences in filament handedness and motor bias (probability of CW rotation). PMID:27499800

  10. The relationship between EMG activity and extensor moment generation in the erector spinae muscles during bending and lifting activities.

    PubMed

    Dolan, P; Adams, M A

    1993-01-01

    The relationship between EMG activity and extensor moment generation in the erector spinae muscles was investigated under isometric and concentric conditions. The full-wave rectified and averaged EMG signal was recorded from skin-surface electrodes located over the belly of the erector spinae at the levels of T10 and L3, and compared with measurements of extensor moment. The effects of muscle length and contraction velocity were studied by measuring the overall curvature (theta) and rate of change of curvature (d theta/dt) of the lumbar spine in the sagittal plane, using the '3-Space Isotrak' system. Isometric contractions were investigated with the subjects pulling up on a load cell attached to the floor. Hand height was varied to produce different amounts of lumbar flexion, as indicated by changes in lumbar curvature. The extensor moment was found to be linearly related to EMG activity, and the 'gradient' and 'intercept' of the relationship were themselves dependent upon the lumbar curvature at the time of testing. Concentric contractions were investigated with the subjects extending from a seated toe-touching position, at various speeds, while the torque exerted on the arm of a Cybex dynamometer was continuously measured. Under these conditions the EMG signal (E) was higher than the isometric signal (E0) associated with the same torque. E and E0 were related as follows: E0 = E/(1 + A d theta/dt), where A = 0.0014 exp (0.045P) and P = percentage lumbar flexion. This equation was used to correct the EMG data for the effect of contraction velocity. The corrected data were then used, in conjunction with the results of the isometric calibrations, to calculate the extensor moment generated by the erector spinae muscles during bending and lifting activities. The extensor moment can itself be used to calculate the compressive force acting on the lumbar spine.

  11. Magnification of starting torques of dc motors by maximum power point trackers in photovoltaic systems

    NASA Technical Reports Server (NTRS)

    Appelbaum, Joseph; Singer, S.

    1989-01-01

    Direct current (dc) motors are used in terrestrial photovoltaic (PV) systems such as in water-pumping systems for irrigation and water supply. Direct current motors may also be used for space applications. Simple and low weight systems including dc motors may be of special interest in space where the motors are directly coupled to the solar cell array (with no storage). The system will operate only during times when sufficient insolation is available. An important performance characteristic of electric motors is the starting to rated torque ratio. Different types of dc motors have different starting torque ratios. These ratios are dictated by the size of solar cell array, and the developed motor torque may not be sufficient to overcome the load starting torque. By including a maximum power point tracker (MPPT) in the PV system, the starting to rated torque ratio will increase, the amount of which depends on the motor type. The starting torque ratio is calculated for the permanent magnet, series and shunt excited dc motors when powered by solar cell arrays for two cases: with and without MPPT's. Defining a motor torque magnification by the ratio of the motor torque with an MPPT to the motor torque without an MPPT, a magnification of 3 was obtained for the permanent magnet motor and a magnification of 7 for both the series and shunt motors. The effect of the variation of solar insolation on the motor starting torque was covered. All motor types are less sensitive to insolation variation in systems including MPPT's as compared to systems with MPPT's. The analysis of this paper will assist the PV system designed to determine whether or not to include an MPPT in the system for a specific motor type.

  12. Partial rupture of the pectoralis major muscle in athletes.

    PubMed

    Roi, G S; Respizzi, S; Dworzak, F

    1990-02-01

    Partial rupture of the pectoralis major muscle is quite a rare event in sports traumatology and information about its treatment is lacking in literature. In this paper the long term effect of conservative non-surgical treatment in two body-builders and one shot-putter is discussed, who reported the partial rupture while performing bench lifts with barbells. Functional recovery was evaluated a few years after the injury (from 4 to 7) with an isokinetic dynamometer (Cybex II, Lumex INC N.Y.), measuring maximal shoulder adduction-abduction torques at different angular speeds (60, 180, and 300 degrees/s). The results were compared with those of five healthy athletes practicing either body-building or weight-lifting. From the present study we conclude the following: the non-invasive treatment of a partial rupture of the pectoralis major muscle may produce almost complete functional recovery; in normal subjects adduction muscles are advantageous in comparison to the abduction ones.

  13. 40 CFR 92.116 - Engine output measurement system calibrations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... spaced torque values as indicated by the master load-cell for each in-use range used. (v) The in-use torque measurement must be within 2 percent of the torque measured by the master system for each load... the calibration equipment described in this section. (2) The engine flywheel torque feedback signals...

  14. Testing and Benchmarking a 2014 GM Silverado 6L80 Six Speed Automatic Transmission

    EPA Science Inventory

    Describe the method and test results of EPA’s partial transmission benchmarking process which involves installing both the engine and transmission in an engine dynamometer test cell with the engine wire harness tethered to its vehicle parked outside the test cell.

  15. 40 CFR 89.6 - Reference materials.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... November 89: Recommended Practice for Engine Testing with Low Temperature Charge Air Cooler Systems in a Dynamometer Test Cell 89.327-96 SAE Paper 770141: Optimization of a Flame Ionization Detector for...

  16. 3D strength surfaces for ankle plantar- and dorsi-flexion in healthy adults: an isometric and isokinetic dynamometry study.

    PubMed

    Hussain, Sara J; Frey-Law, Laura

    2016-01-01

    The ankle is an important component of the human kinetic chain, and deficits in ankle strength can negatively impact functional tasks such as balance and gait. While peak torque is influenced by joint angle and movement velocity, ankle strength is typically reported for a single angle or movement speed. To better identify deficits and track recovery of ankle strength after injury or surgical intervention, ankle strength across a range of movement velocities and joint angles in healthy adults is needed. Thus, the primary goals of this study were to generate a database of strength values and 3-dimensional strength surface models for plantarflexion (PF) and dorsiflexion (DF) ankle strength in healthy men and women. Secondary goals were to develop a means to estimate ankle strength percentiles as well as examine predictors of maximal ankle strength in healthy adults. Using an isokinetic dynamometer, we tested PF and DF peak torques at five joint angles (-10° [DF], 0° [neutral], 10° [PF], 20° [PF] and 30° [PF]) and six velocities (0°/s, 30°/s, 60°/s, 90°/s, 120°/s and 180°/s) in 53 healthy adults. These data were used to generate 3D plots, or "strength surfaces", for males and females for each direction; surfaces were fit using a logistic equation. We also tested predictors of ankle strength, including height, weight, sex, and self-reported physical activity levels. Torque-velocity and torque-angle relationships at the ankle interact, indicating that these relationships are interdependent and best modeled using 3D surfaces. Sex was the strongest predictor of ankle strength over height, weight, and self-reported physical activity levels. 79 to 97 % of the variance in mean peak torque was explained by joint angle and movement velocity using logistic equations, for men and women and PF and DF directions separately. The 3D strength data and surface models provide a more comprehensive dataset of ankle strength in healthy adults than previously reported. These models may allow researchers and clinicians to quantify ankle strength deficits and track recovery in patient populations, using angle- and velocity-specific ankle strength values and/or strength percentiles from healthy adults.

  17. 40 CFR 1066.201 - Dynamometer overview.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Dynamometer overview. 1066.201 Section 1066.201 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.201 Dynamometer overview. This subpart...

  18. Short-Term High Intensity Plyometric Training Program Improves Strength, Power and Agility in Male Soccer Players

    PubMed Central

    Váczi, Márk; Tollár, József; Meszler, Balázs; Juhász, Ivett; Karsai, István

    2013-01-01

    The aim of the present study was to investigate the effects of a short-term in-season plyometric training program on power, agility and knee extensor strength. Male soccer players from a third league team were assigned into an experimental and a control group. The experimental group, beside its regular soccer training sessions, performed a periodized plyometric training program for six weeks. The program included two training sessions per week, and maximal intensity unilateral and bilateral plyometric exercises (total of 40 – 100 foot contacts/session) were executed. Controls participated only in the same soccer training routine, and did not perform plyometrics. Depth vertical jump height, agility (Illinois Agility Test, T Agility Test) and maximal voluntary isometric torque in knee extensors using Multicont II dynamometer were evaluated before and after the experiment. In the experimental group small but significant improvements were found in both agility tests, while depth jump height and isometric torque increments were greater. The control group did not improve in any of the measures. Results of the study indicate that plyometric training consisting of high impact unilateral and bilateral exercises induced remarkable improvements in lower extremity power and maximal knee extensor strength, and smaller improvements in soccer-specific agility. Therefore, it is concluded that short-term plyometric training should be incorporated in the in-season preparation of lower level players to improve specific performance in soccer. PMID:23717351

  19. Short-term high intensity plyometric training program improves strength, power and agility in male soccer players.

    PubMed

    Váczi, Márk; Tollár, József; Meszler, Balázs; Juhász, Ivett; Karsai, István

    2013-03-01

    The aim of the present study was to investigate the effects of a short-term in-season plyometric training program on power, agility and knee extensor strength. Male soccer players from a third league team were assigned into an experimental and a control group. The experimental group, beside its regular soccer training sessions, performed a periodized plyometric training program for six weeks. The program included two training sessions per week, and maximal intensity unilateral and bilateral plyometric exercises (total of 40 - 100 foot contacts/session) were executed. Controls participated only in the same soccer training routine, and did not perform plyometrics. Depth vertical jump height, agility (Illinois Agility Test, T Agility Test) and maximal voluntary isometric torque in knee extensors using Multicont II dynamometer were evaluated before and after the experiment. In the experimental group small but significant improvements were found in both agility tests, while depth jump height and isometric torque increments were greater. The control group did not improve in any of the measures. Results of the study indicate that plyometric training consisting of high impact unilateral and bilateral exercises induced remarkable improvements in lower extremity power and maximal knee extensor strength, and smaller improvements in soccer-specific agility. Therefore, it is concluded that short-term plyometric training should be incorporated in the in-season preparation of lower level players to improve specific performance in soccer.

  20. Improving the Q:H strength ratio in women using plyometric exercises.

    PubMed

    Tsang, Kavin K W; DiPasquale, Angela A

    2011-10-01

    Plyometric training programs have been implemented in anterior cruciate ligament injury prevention programs. Plyometric exercises are designed to aid in the improvement of muscle strength and neuromuscular control. Our purpose was to examine the effects of plyometric training on lower leg strength in women. Thirty (age = 20.3 ± 1.9 years) recreationally active women were divided into control and experimental groups. The experimental group performed a plyometric training program for 6 weeks, 3 d·wk(-1). All subjects attended 4 testing sessions: before the start of the training program and after weeks 2, 4, and 6. Concentric quadriceps and hamstring strength (dominant leg) was assessed using an isokinetic dynamometer at speeds of 60 and 120°·s(-1). Peak torque, average peak torque, and average power (AvgPower) were measured. The results revealed a significant (p < 0.05) interaction between time and group for flexion PkTq and AvgPower at 120°·s(-1). Post hoc analysis further revealed that PkTq at 120°·s(-1) was greater in the plyometric group than in the control group at testing session 4 and that AvgPower was greater in the plyometric group than in the control group in testing sessions 2-4. Our results indicate that the plyometric training program increased hamstring strength while maintaining quadriceps strength, thereby improving the Q:H strength ratio.

  1. Computing the motor torque of Escherichia coli.

    PubMed

    Das, Debasish; Lauga, Eric

    2018-06-13

    The rotary motor of bacteria is a natural nano-technological marvel that enables cell locomotion by powering the rotation of semi-rigid helical flagellar filaments in fluid environments. It is well known that the motor operates essentially at constant torque in counter-clockwise direction but past work have reported a large range of values of this torque. Focusing on Escherichia coli cells that are swimming and cells that are stuck on a glass surface for which all geometrical and environmental parameters are known (N. C. Darnton et al., J. Bacteriol., 2007, 189, 1756-1764), we use two validated numerical methods to compute the value of the motor torque consistent with experiments. Specifically, we use (and compare) a numerical method based on the boundary integral representation of Stokes flow and also develop a hybrid method combining boundary element and slender body theory to model the cell body and flagellar filament, respectively. Using measured rotation speed of the motor, our computations predict a value of the motor torque in the range 440 pN nm to 829 pN nm, depending critically on the distance between the flagellar filaments and the nearby surface.

  2. 40 CFR 1066.275 - Daily dynamometer readiness verification.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.275 Daily... automated process for this verification procedure, perform this evaluation by setting the initial speed and... your dynamometer does not perform this verification with an automated process: (1) With the dynamometer...

  3. Small wind turbine performance evaluation using field test data and a coupled aero-electro-mechanical model

    NASA Astrophysics Data System (ADS)

    Wallace, Brian D.

    A series of field tests and theoretical analyses were performed on various wind turbine rotor designs at two Penn State residential-scale wind-electric facilities. This work involved the prediction and experimental measurement of the electrical and aerodynamic performance of three wind turbines; a 3 kW rated Whisper 175, 2.4 kW rated Skystream 3.7, and the Penn State designed Carolus wind turbine. Both the Skystream and Whisper 175 wind turbines are OEM blades which were originally installed at the facilities. The Carolus rotor is a carbon-fiber composite 2-bladed machine, designed and assembled at Penn State, with the intent of replacing the Whisper 175 rotor at the off-grid system. Rotor aerodynamic performance is modeled using WT_Perf, a National Renewable Energy Laboratory developed Blade Element Momentum theory based performance prediction code. Steady-state power curves are predicted by coupling experimentally determined electrical characteristics with the aerodynamic performance of the rotor simulated with WT_Perf. A dynamometer test stand is used to establish the electromechanical efficiencies of the wind-electric system generator. Through the coupling of WT_Perf and dynamometer test results, an aero-electro-mechanical analysis procedure is developed and provides accurate predictions of wind system performance. The analysis of three different wind turbines gives a comprehensive assessment of the capability of the field test facilities and the accuracy of aero-electro-mechanical analysis procedures. Results from this study show that the Carolus and Whisper 175 rotors are running at higher tip-speed ratios than are optimum for power production. The aero-electro-mechanical analysis predicted the high operating tip-speed ratios of the rotors and was accurate at predicting output power for the systems. It is shown that the wind turbines operate at high tip-speeds because of a miss-match between the aerodynamic drive torque and the operating torque of the wind-system generator. Through the change of load impedance on the wind generator, the research facility has the ability to modify the rotational speed of the wind turbines, allowing the rotors to perform closer to their optimum tip-speed. Comparisons between field test data and performance predictions show that the aero-electro-mechanical analysis was able to predict differences in power production and rotational speed which result from changes in the system load impedance.

  4. 40 CFR 1066.215 - Summary of verification procedures for chassis dynamometers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.215 Summary... judgment. (c) Automated dynamometer verifications and calibrations. In some cases, dynamometers are... specified in this subpart. You may use these automated functions instead of following the procedures we...

  5. EVA Metro Sedan electric-propulsion system: test and evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reimers, E.

    1979-09-01

    The procedure and results of the performance evaluation of the EVA Metro Sedan (car No. 1) variable speed dc chopper motor drive and its three speed automatic transmission are presented. The propulsion system for a battery powered vehicle manufactured by Electric Vehicle Associates, Valley View, Ohio, was removed from the vehicle, mounted on the programmable electric dynamometer test facility and evaluated with the aid of a hp 3052A Data Acquisition System. Performance data for the automatic transmission, the solid state dc motor speed controller, and the dc motor in the continuous and pulsating dc power mode, as derived on themore » dynamometer test facility, as well as the entire propulsion system are given. This concept and the system's components were evaluated in terms of commercial applicability, maintainability, and energy utility to establish a design base for the further development of this system or similar propulsion drives. The propulsion system of the EVA Metro Sedan is powered by sixteen 6-volt traction batteries, Type EV 106 (Exide Battery Mfg. Co.). A thyristor controlled cable form Pulsomatic Mark 10 controller, actuated by a foot throttle, controls the voltage applied to a dc series field motor, rated at 10 hp at 3800 rpm (Baldor Electric Co.). Gear speed reduction to the wheel is accomplished by the original equipment three speed automatic transmission with torque converter (Renault 12 Sedan). The brake consists of a power-assisted, hydraulic braking system with front wheel disk and rear drum. An ability to recuperate electric energy with subsequent storage in the battery power supply is not provided.« less

  6. Heat Control via Torque Control in Friction Stir Welding

    NASA Technical Reports Server (NTRS)

    Venable, Richard; Colligan, Kevin; Knapp, Alan

    2004-01-01

    In a proposed advance in friction stir welding, the torque exerted on the workpiece by the friction stir pin would be measured and controlled in an effort to measure and control the total heat input to the workpiece. The total heat input to the workpiece is an important parameter of any welding process (fusion or friction stir welding). In fusion welding, measurement and control of heat input is a difficult problem. However, in friction stir welding, the basic principle of operation affords the potential of a straightforward solution: Neglecting thermal losses through the pin and the spindle that supports it, the rate of heat input to the workpiece is the product of the torque and the speed of rotation of the friction stir weld pin and, hence, of the spindle. Therefore, if one acquires and suitably processes data on torque and rotation and controls the torque, the rotation, or both, one should be able to control the heat input into the workpiece. In conventional practice in friction stir welding, one uses feedback control of the spindle motor to maintain a constant speed of rotation. According to the proposal, one would not maintain a constant speed of rotation: Instead, one would use feedback control to maintain a constant torque and would measure the speed of rotation while allowing it to vary. The torque exerted on the workpiece would be estimated as the product of (1) the torque-multiplication ratio of the spindle belt and/or gear drive, (2) the force measured by a load cell mechanically coupled to the spindle motor, and (3) the moment arm of the load cell. Hence, the output of the load cell would be used as a feedback signal for controlling the torque (see figure).

  7. 40 CFR 86.118-78 - Dynamometer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... test speed range. The device used to drive the dynamometer is then disengaged from the dynamometer and the roll(s) is (are) allowed to coast down. The kinetic energy of the system is dissipated by the... vehicle. The inertia of the free (rear) roll may be neglected in the case of dynamometers with paired...

  8. 40 CFR 86.118-78 - Dynamometer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... test speed range. The device used to drive the dynamometer is then disengaged from the dynamometer and the roll(s) is (are) allowed to coast down. The kinetic energy of the system is dissipated by the... vehicle. The inertia of the free (rear) roll may be neglected in the case of dynamometers with paired...

  9. 40 CFR 86.118-78 - Dynamometer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... test speed range. The device used to drive the dynamometer is then disengaged from the dynamometer and the roll(s) is (are) allowed to coast down. The kinetic energy of the system is dissipated by the... vehicle. The inertia of the free (rear) roll may be neglected in the case of dynamometers with paired...

  10. 40 CFR 86.118-78 - Dynamometer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... test speed range. The device used to drive the dynamometer is then disengaged from the dynamometer and the roll(s) is (are) allowed to coast down. The kinetic energy of the system is dissipated by the... vehicle. The inertia of the free (rear) roll may be neglected in the case of dynamometers with paired...

  11. Starting characteristics of direct current motors powered by solar cells

    NASA Technical Reports Server (NTRS)

    Singer, S.; Appelbaum, J.

    1989-01-01

    Direct current motors are used in photovoltaic systems. Important characteristics of electric motors are the starting to rated current and torque ratios. These ratios are dictated by the size of the solar cell array and are different for the various dc motor types. Discussed here is the calculation of the starting to rated current ratio and starting to rated torque ratio of the permanent magnet, and series and shunt excited motors when powered by solar cells for two cases: with and without a maximum-power-point-tracker (MPPT) included in the system. Comparing these two cases, one gets a torque magnification of about 3 for the permanent magnet motor and about 7 for other motor types. The calculation of the torques may assist the PV system designer to determine whether or not to include an MPPT in the system.

  12. The Effects of High Intensity Exercise on Overall Leg Strength of Non-Sickel-Cell-Trait and Sickle-Cell-Trait Individuals.

    ERIC Educational Resources Information Center

    Williams, Hill, Jr.; Evans, Mel

    The purpose of this study was to determine if there was any significant difference in overall leg strength gains in individuals with sickle-cell-trait as compared to non-sickle-cell-trait individuals, as measured by the leg dynamometer. Twenty black male first-year college students were used in this study. The subjects were divided into a control…

  13. Electromagnetic torque tweezers: a versatile approach for measurement of single-molecule twist and torque.

    PubMed

    Janssen, Xander J A; Lipfert, Jan; Jager, Tessa; Daudey, Renier; Beekman, Jaap; Dekker, Nynke H

    2012-07-11

    The well-established single-molecule force-spectroscopy techniques have recently been complemented by methods that can measure torque and twist directly, notably magnetic torque tweezers and the optical torque wrench. A limitation of the current torque measurement schemes is the intrinsic coupling between the force and torque degrees of freedom. Here we present electromagnetic torque tweezers (eMTT) that combine permanent and electromagnets to enable independent control of the force and torsional trap stiffness for sensitive measurements of single molecule torque and twist. Using the eMTT, we demonstrate sensitive torque measurements on tethered DNA molecules from simple tracking of the beads' (x,y)-position, obviating the need for any angular tracking algorithms or markers. Employing the eMTT for high-resolution torque measurements, we experimentally confirm the theoretically predicted torque overshoot at the DNA buckling transition in high salt conditions. We envision that the flexibility and control afforded by the eMTT will enable a range of new torque and twist measurement schemes from single-molecules to living cells.

  14. 40 CFR 90.409 - Engine dynamometer test run.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...). (3) Record all pre-test data specified in § 90.405(c). (4) Start the test cycle (see § 90.410) within... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine dynamometer test run. 90.409... Test Procedures § 90.409 Engine dynamometer test run. (a) Engine and dynamometer start-up. (1) Only...

  15. 40 CFR 90.409 - Engine dynamometer test run.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...). (3) Record all pre-test data specified in § 90.405(c). (4) Start the test cycle (see § 90.410) within... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine dynamometer test run. 90.409... Test Procedures § 90.409 Engine dynamometer test run. (a) Engine and dynamometer start-up. (1) Only...

  16. 40 CFR 90.409 - Engine dynamometer test run.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...). (3) Record all pre-test data specified in § 90.405(c). (4) Start the test cycle (see § 90.410) within... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine dynamometer test run. 90.409... Test Procedures § 90.409 Engine dynamometer test run. (a) Engine and dynamometer start-up. (1) Only...

  17. 40 CFR 90.409 - Engine dynamometer test run.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...). (3) Record all pre-test data specified in § 90.405(c). (4) Start the test cycle (see § 90.410) within... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine dynamometer test run. 90.409... Test Procedures § 90.409 Engine dynamometer test run. (a) Engine and dynamometer start-up. (1) Only...

  18. 40 CFR 90.409 - Engine dynamometer test run.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...). (3) Record all pre-test data specified in § 90.405(c). (4) Start the test cycle (see § 90.410) within... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine dynamometer test run. 90.409... Test Procedures § 90.409 Engine dynamometer test run. (a) Engine and dynamometer start-up. (1) Only...

  19. Direct Measurement of Helical Cell Motion of the Spirochete Leptospira

    PubMed Central

    Nakamura, Shuichi; Leshansky, Alexander; Magariyama, Yukio; Namba, Keiichi; Kudo, Seishi

    2014-01-01

    Leptospira are spirochete bacteria distinguished by a short-pitch coiled body and intracellular flagella. Leptospira cells swim in liquid with an asymmetric morphology of the cell body; the anterior end has a long-pitch spiral shape (S-end) and the posterior end is hook-shaped (H-end). Although the S-end and the coiled cell body called the protoplasmic cylinder are thought to be responsible for propulsion together, most observations on the motion mechanism have remained qualitative. In this study, we analyzed the swimming speed and rotation rate of the S-end, protoplasmic cylinder, and H-end of individual Leptospira cells by one-sided dark-field microscopy. At various viscosities of media containing different concentrations of Ficoll, the rotation rate of the S-end and protoplasmic cylinder showed a clear correlation with the swimming speed, suggesting that these two helical parts play a central role in the motion of Leptospira. In contrast, the H-end rotation rate was unstable and showed much less correlation with the swimming speed. Forces produced by the rotation of the S-end and protoplasmic cylinder showed that these two helical parts contribute to propulsion at nearly equal magnitude. Torque generated by each part, also obtained from experimental motion parameters, indicated that the flagellar motor can generate torque >4000 pN nm, twice as large as that of Escherichia coli. Furthermore, the S-end torque was found to show a markedly larger fluctuation than the protoplasmic cylinder torque, suggesting that the unstable H-end rotation might be mechanically related to changes in the S-end rotation rate for torque balance of the entire cell. Variations in torque at the anterior and posterior ends of the Leptospira cell body could be transmitted from one end to the other through the cell body to coordinate the morphological transformations of the two ends for a rapid change in the swimming direction. PMID:24411236

  20. Direct measurement of helical cell motion of the spirochete leptospira.

    PubMed

    Nakamura, Shuichi; Leshansky, Alexander; Magariyama, Yukio; Namba, Keiichi; Kudo, Seishi

    2014-01-07

    Leptospira are spirochete bacteria distinguished by a short-pitch coiled body and intracellular flagella. Leptospira cells swim in liquid with an asymmetric morphology of the cell body; the anterior end has a long-pitch spiral shape (S-end) and the posterior end is hook-shaped (H-end). Although the S-end and the coiled cell body called the protoplasmic cylinder are thought to be responsible for propulsion together, most observations on the motion mechanism have remained qualitative. In this study, we analyzed the swimming speed and rotation rate of the S-end, protoplasmic cylinder, and H-end of individual Leptospira cells by one-sided dark-field microscopy. At various viscosities of media containing different concentrations of Ficoll, the rotation rate of the S-end and protoplasmic cylinder showed a clear correlation with the swimming speed, suggesting that these two helical parts play a central role in the motion of Leptospira. In contrast, the H-end rotation rate was unstable and showed much less correlation with the swimming speed. Forces produced by the rotation of the S-end and protoplasmic cylinder showed that these two helical parts contribute to propulsion at nearly equal magnitude. Torque generated by each part, also obtained from experimental motion parameters, indicated that the flagellar motor can generate torque >4000 pN nm, twice as large as that of Escherichia coli. Furthermore, the S-end torque was found to show a markedly larger fluctuation than the protoplasmic cylinder torque, suggesting that the unstable H-end rotation might be mechanically related to changes in the S-end rotation rate for torque balance of the entire cell. Variations in torque at the anterior and posterior ends of the Leptospira cell body could be transmitted from one end to the other through the cell body to coordinate the morphological transformations of the two ends for a rapid change in the swimming direction. Copyright © 2014 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  1. Association of Quadriceps Strength and Psychosocial Factors With Single-Leg Hop Performance in Patients With Meniscectomy.

    PubMed

    Hsu, Chao-Jung; George, Steven Z; Chmielewski, Terese L

    2016-12-01

    Clinicians use the single-leg hop test to assess readiness for return to sports after knee injury. Few studies have reported the results of single-leg hop testing after meniscectomy. Additionally, the contributions of impairments in quadriceps strength and psychosocial factors to single-leg hop performance are unknown. To compare single-leg hop performance (distance and landing mechanics) between limbs and to examine the association of single-leg hop performance with quadriceps strength and psychosocial factors in patients with meniscectomy. Descriptive laboratory study. A total of 22 subjects who underwent meniscectomy for traumatic meniscal tears received either standard rehabilitation alone or with additional quadriceps strengthening. Testing was conducted immediately postrehabilitation and at 1 year postsurgery. A single-leg hop test was performed bilaterally, and hop distance was used to create a hop symmetry index. Landing mechanics (peak knee flexion angle, knee extension moment, and peak vertical ground-reaction force) were analyzed with a motion-capture system and a force plate. An isokinetic dynamometer (60 deg/s) assessed knee extensor peak torque and rate of torque development (RTD 0-200ms and RTD 0-peak torque ). Questionnaires assessed fear of reinjury (Tampa Scale for Kinesiophobia [TSK-11]) and self-efficacy (Knee Activity Self-Efficacy [KASE]). Rehabilitation groups did not significantly differ in single-leg hop performance; therefore, groups were combined for further analyses. The mean hop symmetry index was 88.6% and 98.9% at postrehabilitation and 1 year postsurgery, respectively. Compared with the nonsurgical limb, the surgical limb showed decreased peak knee flexion angle at postrehabilitation and decreased knee extension moment at 1 year postsurgery. The hop symmetry index was positively associated with peak torque, RTD 0-200ms , and the KASE score at postrehabilitation. Moreover, at postrehabilitation, the peak knee flexion angle was positively associated with peak torque and RTD 0-200ms , and the knee extension moment was positively associated with RTD 0-200ms . At 1 year postsurgery, peak knee flexion angle and knee extension moment were both positively associated with peak torque, RTD 0-200ms , and RTD 0-peak torque . Although the hop symmetry index could be considered satisfactory for returning to sports, asymmetries in landing mechanics still exist in the first year postmeniscectomy. Greater quadriceps strength was associated with greater single-leg hop distance and better landing mechanics at both postrehabilitation and 1 year postsurgery. Knee activity self-efficacy was the only psychosocial factor associated with single-leg hop performance and isolated to a positive association with single-leg hop distance at postrehabilitation. Rate of development is not typically measured in the clinic but can be an additional quadriceps measure to monitor for single-leg hop performance. Quadriceps strength and psychosocial factors appear to have separate influence on single-leg hop performance after meniscectomy, which has implications for developing appropriate interventions for optimal single-leg hop performance.

  2. Association of Quadriceps Strength and Psychosocial Factors With Single-Leg Hop Performance in Patients With Meniscectomy

    PubMed Central

    Hsu, Chao-Jung; George, Steven Z.; Chmielewski, Terese L.

    2016-01-01

    Background: Clinicians use the single-leg hop test to assess readiness for return to sports after knee injury. Few studies have reported the results of single-leg hop testing after meniscectomy. Additionally, the contributions of impairments in quadriceps strength and psychosocial factors to single-leg hop performance are unknown. Purpose: To compare single-leg hop performance (distance and landing mechanics) between limbs and to examine the association of single-leg hop performance with quadriceps strength and psychosocial factors in patients with meniscectomy. Study Design: Descriptive laboratory study. Methods: A total of 22 subjects who underwent meniscectomy for traumatic meniscal tears received either standard rehabilitation alone or with additional quadriceps strengthening. Testing was conducted immediately postrehabilitation and at 1 year postsurgery. A single-leg hop test was performed bilaterally, and hop distance was used to create a hop symmetry index. Landing mechanics (peak knee flexion angle, knee extension moment, and peak vertical ground-reaction force) were analyzed with a motion-capture system and a force plate. An isokinetic dynamometer (60 deg/s) assessed knee extensor peak torque and rate of torque development (RTD0-200ms and RTD0–peak torque). Questionnaires assessed fear of reinjury (Tampa Scale for Kinesiophobia [TSK-11]) and self-efficacy (Knee Activity Self-Efficacy [KASE]). Results: Rehabilitation groups did not significantly differ in single-leg hop performance; therefore, groups were combined for further analyses. The mean hop symmetry index was 88.6% and 98.9% at postrehabilitation and 1 year postsurgery, respectively. Compared with the nonsurgical limb, the surgical limb showed decreased peak knee flexion angle at postrehabilitation and decreased knee extension moment at 1 year postsurgery. The hop symmetry index was positively associated with peak torque, RTD0-200ms, and the KASE score at postrehabilitation. Moreover, at postrehabilitation, the peak knee flexion angle was positively associated with peak torque and RTD0-200ms, and the knee extension moment was positively associated with RTD0-200ms. At 1 year postsurgery, peak knee flexion angle and knee extension moment were both positively associated with peak torque, RTD0-200ms, and RTD0–peak torque. Conclusion: Although the hop symmetry index could be considered satisfactory for returning to sports, asymmetries in landing mechanics still exist in the first year postmeniscectomy. Greater quadriceps strength was associated with greater single-leg hop distance and better landing mechanics at both postrehabilitation and 1 year postsurgery. Knee activity self-efficacy was the only psychosocial factor associated with single-leg hop performance and isolated to a positive association with single-leg hop distance at postrehabilitation. Clinical Relevance: Rate of development is not typically measured in the clinic but can be an additional quadriceps measure to monitor for single-leg hop performance. Quadriceps strength and psychosocial factors appear to have separate influence on single-leg hop performance after meniscectomy, which has implications for developing appropriate interventions for optimal single-leg hop performance. PMID:28210647

  3. 40 CFR 86.208-94 - Dynamometer.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Passenger Vehicles; Cold Temperature Test Procedures § 86.208-94 Dynamometer. (a) For testing that is... the manufacturer, a dynamometer with different characteristics may be used provided cold CO emissions...

  4. 40 CFR 86.208-94 - Dynamometer.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Passenger Vehicles; Cold Temperature Test Procedures § 86.208-94 Dynamometer. (a) For testing that is... the manufacturer, a dynamometer with different characteristics may be used provided cold CO emissions...

  5. 40 CFR 86.208-94 - Dynamometer.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Passenger Vehicles; Cold Temperature Test Procedures § 86.208-94 Dynamometer. (a) For testing that is... the manufacturer, a dynamometer with different characteristics may be used provided cold CO emissions...

  6. Asymmetry in the clockwise and counterclockwise rotation of the bacterial flagellar motor

    PubMed Central

    Yuan, Junhua; Fahrner, Karen A.; Turner, Linda; Berg, Howard C.

    2010-01-01

    Cells of Escherichia coli are able to swim up gradients of chemical attractants by modulating the direction of rotation of their flagellar motors, which spin alternately clockwise (CW) and counterclockwise (CCW). Rotation in either direction has been thought to be symmetric and exhibit the same torques and speeds. The relationship between torque and speed is one of the most important measurable characteristics of the motor, used to distinguish specific mechanisms of motor rotation. Previous measurements of the torque–speed relationship have been made with cells lacking the response regulator CheY that spin their motors exclusively CCW. In this case, the torque declines slightly up to an intermediate speed called the “knee speed” after which it falls rapidly to zero. This result is consistent with a “power-stroke” mechanism for torque generation. Here, we measure the torque–speed relationship for cells that express large amounts of CheY and only spin their motors CW. We find that the torque decreases linearly with speed, a result remarkably different from that for CCW rotation. We obtain similar results for wild-type cells by reexamining data collected in previous work. We speculate that CCW rotation might be optimized for runs, with higher speeds increasing the ability of cells to sense spatial gradients, whereas CW rotation might be optimized for tumbles, where the object is to change cell trajectories. But why a linear torque–speed relationship might be optimum for the latter purpose we do not know. PMID:20615986

  7. Assessment of isokinetic knee strength in elite young female basketball players: correlation with vertical jump.

    PubMed

    Rouis, M; Coudrat, L; Jaafar, H; Filliard, J-R; Vandewalle, H; Barthelemy, Y; Driss, T

    2015-12-01

    To explore the isokinetic concentric strength of the knee muscle groups, and the relationship between the isokinetic knee extensors strength and the vertical jump performance in young elite female basketball players. Eighteen elite female basketball players performed a countermovement jump, and an isokinetic knee test using a Biodex dynamometer. The maximal isokinetic peak torque of the knee extensor and flexor muscles was recorded at four angular velocities (90°/s, 180°/s, 240°/s and 300°/s) for the dominant and non-dominant legs. The conventional hamstring/quadriceps ratio (H/Q) was assessed at each angular velocity for both legs. There was no significant difference between dominant and non-dominant leg whatever the angular velocity (all P>0.05). However, the H/Q ratio enhanced as the velocity increased from 180°/s to 300°/s (P<0.05). Furthermore, low to high significant positive correlations were detected between the isokinetic measures of the knee extensors and the vertical jump height. The highest one was found for the knee extensors peak torque at a velocity of 240°/s (r=0.88, P<0.001). The results accounted for an optimal velocity at which a strong relationship could be obtained between isokinetic knee extensors strength and vertical jump height. Interestingly, the H/Q ratio of the young elite female basketball players in the present study was unusual as it was close to that generally observed in regular sportsmen.

  8. Myofibrillar and collagen protein synthesis in human skeletal muscle in young men after maximal shortening and lengthening contractions.

    PubMed

    Moore, Daniel R; Phillips, Stuart M; Babraj, John A; Smith, Kenneth; Rennie, Michael J

    2005-06-01

    We aimed to determine whether there were differences in the extent and time course of skeletal muscle myofibrillar protein synthesis (MPS) and muscle collagen protein synthesis (CPS) in human skeletal muscle in an 8.5-h period after bouts of maximal muscle shortening (SC; average peak torque = 225 +/- 7 N.m, means +/- SE) or lengthening contractions (LC; average peak torque = 299 +/- 18 N.m) with equivalent work performed in each mode. Eight healthy young men (21.9 +/- 0.6 yr, body mass index 24.9 +/- 1.3 kg/m2) performed 6 sets of 10 maximal unilateral LC of the knee extensors on an isokinetic dynamometer. With the contralateral leg, they then performed 6 sets of maximal unilateral SC with work matched to the total work performed during LC (10.9 +/- 0.7 vs. 10.9 +/- 0.8 kJ, P = 0.83). After exercise, the participants consumed small intermittent meals to provide 0.1 g.kg(-1).h(-1) of protein and carbohydrate. Prior exercise elevated MPS above rest in both conditions, but there was a more rapid rise after LC (P < 0.01). The increases (P < 0.001) in CPS above rest were identical for both SC and LC and likely represent a remodeling of the myofibrillar basement membrane. Therefore, a more rapid rise in MPS after maximal LC could translate into greater protein accretion and muscle hypertrophy during chronic resistance training utilizing maximal LC.

  9. Associations between muscle structure and contractile performance in seniors.

    PubMed

    Randhawa, Avleen; Wakeling, James M

    2013-07-01

    Changes in muscle structure due to aging occur in a process known as sarcopenia. These changes can alter muscle mechanics during contraction that may limit mobility in seniors. The purpose of this study was to investigate the effect of sarcopenia on muscle fascicle length, pennation and belly thickness in a contracting muscle during isokinetic movements. Fascicles within a pennate muscle shorten at a slower velocity than that of the muscle belly, in a process called belly gearing. Belly gearing may be affected by atrophy and so was also tested in these seniors. The gastrocnemii were tested using ultrasound from 10 young adults (20-40 years) and 9 seniors (70-85 years). The muscle structure was imaged during standing and maximal plantarflexion at four constant velocities on a dynamometer and torque, position and time were recorded during contractions. The muscle belly thickness and pennation in seniors were significantly lower than young adults during standing. Belly thickness, changes in pennation, the belly gearing, ankle torque and power output were all significantly lower in seniors during plantarflexion contractions of the medial gastrocnemius (MG) and lateral gastrocnemius (LG). The higher pennation observed in young adults is commonly associated with increased fascicle rotations during contraction causing an increased belly gearing. The decreased fascicle rotations in seniors resulted in reduced belly gearing but the size of this effect did not match the loss in strength or power from the muscles. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. The association between physical characteristics of the ankle joint and the mobility performance in elderly people with type 2 diabetes mellitus.

    PubMed

    Ng, Thomas Ka-Wai; Lo, Sing-Kai; Cheing, Gladys Lai-Ying

    2014-01-01

    Previous studies showed that older adults with diabetes have a worse mobility performance as compared with those without diabetes. Studies also demonstrated that older adults with diabetes have weakened ankle muscle strength, reduced joint range in ankle dorsiflexion and worsened ankle joint proprioception as compared with control population. The purpose of the present study was to examine the relationship between the physical characteristics of the ankle joint and the mobility performance in older adults with type 2 diabetes. Older adults with type 2 diabetes (n=85) were recruited, and Timed Up and Go test (TUG) for mobility assessment was performed. Active ankle joint repositioning test was used for assessing the ankle joint proprioception sense; peak torque of ankle dorsiflexors and plantar flexors were tested by using a Cybex Norm dynamometer, and weight-bearing lunge test (WBLT) was used for assessing the stiffness of ankle dorsiflexion. Our results showed that age, body mass index (BMI), normalized peak torque of plantar flexors and dorsiflexors, active ankle joint repositioning test errors and the WBLT distance were significantly correlated with the TUG (all p<0.001). These ankle characteristics, together with the demographic data of the subjects, contributed 59.9% of the variance in the TUG by multiple regression analysis. Body mass, ankle plantar flexors strength and ankle joint proprioception are important factors contributing to the physical mobility of the older adults with type 2 diabetes. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Effects of Lumbar Strengthening Exercise in Lower-Limb Amputees With Chronic Low Back Pain.

    PubMed

    Shin, Min Kyung; Yang, Hee Seung; Yang, Hea-Eun; Kim, Dae Hyun; Ahn, Bo Ram; Kwon, Hyup; Lee, Ju Hwan; Jung, Suk; Choi, Hyun Chul; Yun, Sun Keaung; Ahn, Dong Young; Sim, Woo Sob

    2018-02-01

    To analyze the effect of lumbar strengthening exercise in lower-limb amputees with chronic low back pain. We included in this prospective study 19 lower-limb amputees who had experienced low back pain for longer than 6 months. Participants were treated with 30-minute lumbar strengthening exercises, twice weekly, for 8 weeks. We used the visual analog scale (VAS), and Oswestry low back pain disability questionnaire, and measured parameters such as iliopsoas length, abdominal muscle strength, back extensor strength, and back extensor endurance. In addition, we assessed the isometric peak torque and total work of the trunk flexors and extensors using isokinetic dynamometer. The pre- and post-exercise measurements were compared. Compared with the baseline, abdominal muscle strength (from 4.4±0.7 to 4.8±0.6), back extensor strength (from 2.6±0.6 to 3.5±1.2), and back extensor endurance (from 22.3±10.7 to 46.8±35.1) improved significantly after 8 weeks. The VAS decreased significantly from 4.6±2.2 to 2.6±1.6 after treatment. Furthermore, the peak torque and total work of the trunk flexors and extensors increased significantly (p<0.05). Lumbar strengthening exercise in lower-limb amputees with chronic low back pain resulted in decreased pain and increased lumbar extensor strength. The lumbar strengthening exercise program is very effective for lower-limb amputees with chronic low back pain.

  12. Relationship between muscle mass and physical performance: is it the same in older adults with weak muscle strength?

    PubMed

    Kim, Kyoung-Eun; Jang, Soong-Nang; Lim, Soo; Park, Young Joo; Paik, Nam-Jong; Kim, Ki Woong; Jang, Hak Chul; Lim, Jae-Young

    2012-11-01

    the relationship between muscle mass and physical performance has not been consistent among studies. to clarify the relationship between muscle mass and physical performance in older adults with weak muscle strength. cross-sectional analysis using the baseline data of 542 older men and women from the Korean Longitudinal Study on Health and Aging. dual X-ray absorptiometry, isokinetic dynamometer and the Short Physical Performance Battery (SPPB) were performed. Two muscle mass parameters, appendicular skeletal mass divided by weight (ASM/Wt) and by height squared (ASM/Ht(2)), were measured. We divided the participants into a lower-quartile (L25) group and an upper-three-quartiles (H75) group based on the knee-extensor peak torque. Correlation analysis and logistic regression models were used to assess the association between muscle mass and low physical performance, defined as SPPB scores <9, after controlling for confounders. in the L25 group, no correlation between mass and SPPB was detected, whereas the correlation between peak torque and SPPB was significant and higher than that in the H75 group. Results from the logistic models also showed no association between muscle mass and SPPB in the L25 group, whereas muscle mass was associated with SPPB in the H75 group. muscle mass was not associated with physical performance in weak older adults. Measures of muscle strength may be of greater clinical importance in weak older adults than is muscle mass per se.

  13. Effect of a lateral step-up exercise protocol on quadriceps and lower extremity performance.

    PubMed

    Worrell, T W; Borchert, B; Erner, K; Fritz, J; Leerar, P

    1993-12-01

    Closed kinetic chain exercises have been promoted as more functional and more appropriate than open kinetic chain exercises. Limited research exists demonstrating the effect of closed kinetic chain exercise on quadriceps and lower extremity performance. The purpose of this study was to determine the effect of a lateral step-up exercise protocol on isokinetic quadriceps peak torque and the following lower extremity activities: 1) leg press, 2) maximal step-up repetitions with body weight plus 25%, 3) hop for distance, and 4) 6-m timed hop. Twenty subjects participated in a 4-week training period, and 18 subjects served as controls. For the experimental group, a repeated measure ANOVA comparing pretest and posttest values revealed significant improvements in the leg press (p < or = .05), step-ups (p < or = .05), hop for distance (p < or = .05), and hop for time (p < or = .05) and no significant increase in isokinetic quadriceps peak torque (p > or = .05). Over the course of the training period, weight used for the step-up exercise increased (p < or = .05), repetitions decreased (p < or = .05), and step-up work did not change (p > or = .05). For the control group, no significant change (p > or = .05) occurred in any variable. The inability of the isokinetic dynamometer to detect increases in quadriceps performance is important because the isokinetic values are frequently used as criteria for return to functional activities. We conclude that closed kinetic chain testing and exercise provide additional means to assess and rehabilitate the lower extremity.

  14. 40 CFR 86.518-78 - Dynamometer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... down the dynamometer for each inertia load combination used. Coastdown times for the interval from 70... of conducting a dynamometer coastdown at one or more inertia-horsepower settings and comparing the...

  15. 40 CFR 86.518-78 - Dynamometer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... down the dynamometer for each inertia load combination used. Coastdown times for the interval from 70... of conducting a dynamometer coastdown at one or more inertia-horsepower settings and comparing the...

  16. 40 CFR 86.518-78 - Dynamometer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... down the dynamometer for each inertia load combination used. Coastdown times for the interval from 70... of conducting a dynamometer coastdown at one or more inertia-horsepower settings and comparing the...

  17. 40 CFR 86.518-78 - Dynamometer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... down the dynamometer for each inertia load combination used. Coastdown times for the interval from 70... of conducting a dynamometer coastdown at one or more inertia-horsepower settings and comparing the...

  18. 40 CFR 86.518-78 - Dynamometer calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... down the dynamometer for each inertia load combination used. Coastdown times for the interval from 70... of conducting a dynamometer coastdown at one or more inertia-horsepower settings and comparing the...

  19. 40 CFR 86.118-00 - Dynamometer calibrations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 1977 and Later Model Year New Light-Duty Vehicles and New Light-Duty Trucks and New Otto-Cycle Complete... required. (b) For large single roll electric dynamometers or equivalent dynamometer configurations, the...

  20. Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility

    PubMed Central

    Wiesinger, Hans-Peter; Wiemer, Nicolas; Kösters, Alexander; Müller, Erich

    2016-01-01

    Abstract The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48–72 h. The intraclass correlation coefficient (ICC 2,1) and the coefficient of variation (CV) were calculated for (i) maximum torque (MVC), (ii) the peak rate of torque development (RTDpeak) as well as for (iii) the average rate of torque development (RTD) and the impulse taken at several predefined time intervals (0–30 to 0–300 ms); thereby explosive strength variables were derived in two conceptually different versions: on the one hand from the MVC-trial (version I), on the other hand from the trial showing the RTDpeak (version II). High ICC-values (0.80–0.99) and acceptable CV-values (1.9–8.7%) could be found for MVC as well as for the RTD and the impulse taken at time intervals of ≥100 ms, regardless of whether version I or II was used. In contrast, measurements of the RTDpeak as well as the RTD and the impulse taken during the very early contraction phase (i.e. RTD/impulse0–30ms and RTD/impulse0–50ms) showed clearly weaker reproducibility results (ICC: 0.53–0.84; CV: 7.3–16.4%) and gave rise to considerable doubts as to clinical usefulness, especially when derived using version I. However, if there is a need to measure explosive strength for earlier time intervals in practice, it is, in view of stronger reproducibility results, recommended to concentrate on measures derived from version II, which is based on the RTDpeak-trial. PMID:28149337

  1. Ankle Joint Angle and Lower Leg Musculotendinous Unit Responses to Cryotherapy.

    PubMed

    Akehi, Kazuma; Long, Blaine C; Warren, Aric J; Goad, Carla L

    2016-09-01

    Akehi, K, Long, BC, Warren, AJ, and Goad, CL. Ankle joint angle and lower leg musculotendinous unit responses to cryotherapy. J Strength Cond Res 30(9): 2482-2492, 2016-The use of cold application has been debated for its influence on joint range of motion (ROM) and stiffness. The purpose of this study was to determine whether a 30-minute ice bag application to the plantarflexor muscles or ankle influences passive ankle dorsiflexion ROM and lower leg musculotendinous stiffness (MTS). Thirty-five recreationally active college-aged individuals with no history of lower leg injury 6 months before data collection volunteered. On each testing day, we measured maximum passive ankle dorsiflexion ROM (°) and plantarflexor torque (N·m) on an isokinetic dynamometer to calculate the passive plantarflexor MTS (N·m per degree) at 4 joint angles before, during, and after a treatment. Surface electromyography amplitudes (μV), and skin surface and ambient air temperature (°C) were also measured. Subjects received an ice bag to the posterior lower leg, ankle joint, or nothing for 30 minutes in different days. Ice bag application to the lower leg and ankle did not influence passive ROM (F(12,396) = 0.67, p = 0.78). Passive torque increased after ice bag application to the lower leg (F(12,396) = 2.21, p = 0.011). Passive MTS at the initial joint angle increased after ice bag application to the lower leg (F(12,396) = 2.14, p = 0.014) but not at the other joint angles (p > 0.05). Surface electromyography amplitudes for gastrocnemius and soleus muscles increased after ice application to the lower leg (F(2,66) = 5.61, p = 0.006; F(12,396) = 3.60, p < 0.001). Ice bag application to the lower leg and ankle joint does not alter passive dorsiflexion ROM but increases passive ankle plantarflexor torque in addition to passive ankle plantarflexor MTS at the initial joint angle.

  2. Soccer-Specific Fatigue and Eccentric Hamstrings Muscle Strength

    PubMed Central

    Greig, Matt; Siegler, Jason C

    2009-01-01

    Context: Epidemiologic findings of higher incidences of hamstrings muscle strains during the latter stages of soccer match play have been attributed to fatigue. Objective: To investigate the influence of soccer-specific fatigue on the peak eccentric torque of the knee flexor muscles. Design: Descriptive laboratory study. Setting: Controlled laboratory environment. Patients or Other Participants: Ten male professional soccer players (age  =  24.7 ± 4.4 years, mass  =  77.1 ± 8.3 kg, V̇o2max  =  63.0 ± 4.8 mL·kg−1·min−1). Intervention(s): Participants completed an intermittent treadmill protocol replicating the activity profile of soccer match play, with a passive halftime interval. Before exercise and at 15-minute intervals, each player completed isokinetic dynamometer trials. Main Outcome Measure(s): Peak eccentric knee flexor torque was quantified at isokinetic speeds of 180° · s−1, 300° · s−1, and 60° · s−1, with 5 repetitions at each speed. Results: Peak eccentric knee flexor torque at the end of the game (T300eccH105  =  127 ± 25 Nm) and at the end of the passive halftime interval (T300eccH60  =  133 ± 32 Nm) was reduced relative to T300eccH00 (167 ± 35 Nm, P < .01) and T300eccH15 (161 ± 35 Nm, P  =  .02). Conclusions: Eccentric hamstrings strength decreased as a function of time and after the halftime interval. This finding indicates a greater risk of injuries at these specific times, especially for explosive movements, in accordance with epidemiologic observations. Incorporating eccentric knee flexor exercises into resistance training sessions that follow soccer-specific conditioning is warranted to try to reduce the incidence or recurrence of hamstrings strains. PMID:19295963

  3. Associations Among Quadriceps Strength and Rate of Torque Development 6 Weeks Post Anterior Cruciate Ligament Reconstruction and Future Hop and Vertical Jump Performance: A Prospective Cohort Study.

    PubMed

    Pua, Yong-Hao; Mentiplay, Benjamin F; Clark, Ross A; Ho, Jia-Ying

    2017-11-01

    Study Design Prospective cohort. Background Quadriceps strength is associated with hop distance and jump height in persons who have undergone anterior cruciate ligament (ACL) reconstruction. However, it is unknown whether the ability to rapidly generate quadriceps torque in the early phase of recovery is associated with future hopping and jumping performance in this population. Objective To evaluate the prospective associations among quadriceps strength and rate of torque development (RTD) and single-leg hop for distance, vertical jump height, vertical ground reaction force (vGRF), and vertical force loading rate during a landing task in persons who have undergone ACL reconstruction. Methods Seventy patients with unilateral ACL reconstruction participated. At 6 weeks post ACL reconstruction, isometric quadriceps strength and RTD were measured using a dynamometer. At 6 months following ACL reconstruction, patients performed the single-leg hop for distance test. Patients also performed the single-leg vertical jump test on a force plate that measured maximum jump height, vGRF, and average loading rate during landing. Results Both quadriceps strength and RTD at 6 weeks post ACL reconstruction were associated with all hopping and jumping measures at 6 months post ACL reconstruction (P≤.04). Single-leg hop distance was associated more closely with quadriceps strength than with quadriceps RTD (P = .05), and vertical jump height and vGRF measures were associated more closely with quadriceps RTD than with quadriceps strength (P = .05 and P<.01, respectively). Both quadriceps measures were associated with loading rate. Conclusion Quadriceps strength and RTD are complementary but distinct predictors of future hopping and jumping performance in persons who have undergone ACL reconstruction. These findings may contribute to improved rehabilitation of patients who are at risk for poor jumping/hopping performance and abnormal knee loading. J Orthop Sports Phys Ther 2017;47(11):845-852. Epub 13 Oct 2017. doi:10.2519/jospt.2017.7133.

  4. [Correlations Between Joint Proprioception, Muscle Strength, and Functional Ability in Patients with Knee Osteoarthritis].

    PubMed

    Chen, Yoa; Yu, Yong; He, Cheng-qi

    2015-11-01

    To establish correlations between joint proprioception, muscle flexion and extension peak torque, and functional ability in patients with knee osteoarthritis (OA). Fifty-six patients with symptomatic knee OA were recruited in this study. Both proprioceptive acuity and muscle strength were measured using the isomed-2000 isokinetic dynamometer. Proprioceptive acuity was evaluated by establishing the joint motion detection threshold (JMDT). Muscle strength was evaluated by Max torque (Nm) and Max torque/weight (Nm/ kg). Functional ability was assessed by the Western Ontario and McMaster Universities Osteoarthritis Index physical function (WOMAC-PF) questionnaire. Correlational analyses were performed between proprioception, muscle strength, and functional ability. A multiple stepwise regression model was established, with WOMAC-PF as dependent variable and patient age, body mass index (BMI), visual analogue scale (VAS)-score, mean grade for Kellgren-Lawrance of both knees, mean strength for quadriceps and hamstring muscles of both knees, and mean JMDT of both knees as independent variables. Poor proprioception (high JMDT) was negatively correlated with muscle strength (P<0.05). There was no significant correlation between knee proprioception (high JMDT) and joint pain (WOMAC pain score), and between knee proprioception (high JMDT) and joint stiffness (WOMAC stiffness score). Poor proprioception (high JMDT) was correlated with limitation in functional ability (WOMAC physical function score r=0.659, P<0.05). WOMAC score was correlated with poor muscle strength (quadriceps muscle strength r = -0.511, P<0.05, hamstring muscle strength r = -0.408, P<0.05). The multiple stepwise regression model showed that high JMDT C standard partial regression coefficient (B) = 0.385, P<0.50 and high VAS-scale score (B=0.347, P<0.05) were significant predictors of WOMAC-PF score. Patients with poor proprioception is associated with poor muscle strength and limitation in functional ability. Patients with symptomatic OA of knees commonly endure with moderate to considerable dysfunction, which is associated with poor proprioception (high JMDT) and high VAS-scale score.

  5. Effects of knee and ankle muscle fatigue on postural control in the unipedal stance.

    PubMed

    Bizid, Riadh; Margnes, Eric; François, Yrieix; Jully, Jean Louis; Gonzalez, Gerard; Dupui, Philippe; Paillard, Thierry

    2009-06-01

    The aim of this study was to compare the effects of acute muscle fatigue of the ankle and knee musculature on postural control by immediate measures after performing fatiguing tasks (POST condition). One group of subjects (n = 8) performed a fatiguing task by voluntary contractions of the triceps surae (group TRI) and the other (n = 9) performed a fatiguing task by voluntary contractions of the quadriceps femoris (group QUA). Each muscle group was exercised until the loss of maximal voluntary contraction torque reached 50% (isokinetic dynamometer). Posture was assessed by measuring the centre of foot pressure (COP) with a force platform during a test of unipedal quiet standing posture with eyes closed. Initially (in PRE condition), the mean COP velocity was not significantly different between group TRI and group QUA. In POST condition, the mean COP velocity increased more in group QUA than in group TRI. The postural control was more impaired by knee muscle fatigue than by ankle muscle fatigue.

  6. Behavior of aircraft antiskid braking systems on dry and wet runway surfaces: Hydromechanically controlled system

    NASA Technical Reports Server (NTRS)

    Tanner, J. A.; Stubbs, S. M.; Smith, E. G.

    1981-01-01

    The investigation utilized one main gear wheel, brake, and tire assembly of a McDonnell Douglas DC-9 series 10 airplane. The landing-gear strut was replaced by a dynamometer. During maximum braking, average braking behavior indexes based upon brake pressure, brake torque, and drag-force friction coefficient developed by the antiskid system were generally higher on dry surfaces than on wet surfaces. The three braking behavior indexes gave similar results but should not be used interchangeably as a measure of the braking of this antiskid sytem. During the transition from a dry to a flooded surface under heavy braking, the wheel entered into a deep skid but the antiskid system reacted quickly by reducing brake pressure and performed normally during the remainder of the run on the flooded surface. The brake-pressure recovery following transition from a flooded to a dry surface was shown to be a function of the antiskid modulating orifice.

  7. Experimental Investigation of Bearing Slip in a Wind Turbine Gearbox During a Transient Grid Loss Event

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helsen, Jan; Guo, Yi; Keller, Jonathan

    This work investigates the behaviour of the high speed stage of a wind turbine gearbox during a transient grid loss event. Dynamometer testing on a full scale wind turbine nacelle is used. A combination of external and internal gearbox measurements is analysed. Particular focus is on the characterization of the high speed shaft tapered roller bearing slip behaviour. This slipping behaviour is linked to dynamic events by many researchers and described as potential bearing failure initiator. However only limited full scale dynamic testing is documented. Strain gauge bridges in grooves along the circumference of the outer ring are used tomore » characterize the bearing behaviour in detail. It is shown that during the transient event the high speed shaft experiences a combined torsional and bending deformation. These unfavourable loading conditions induce roller slip in the bearings during the torque reversals indicating the potential of the applied load case to go beyond the preload of the tapered roller bearing.« less

  8. Two-Speed Gearbox Dynamic Simulation Predictions and Test Validation

    NASA Technical Reports Server (NTRS)

    Lewicki, David G.; DeSmidt, Hans; Smith, Edward C.; Bauman, Steven W.

    2010-01-01

    Dynamic simulations and experimental validation tests were performed on a two-stage, two-speed gearbox as part of the drive system research activities of the NASA Fundamental Aeronautics Subsonics Rotary Wing Project. The gearbox was driven by two electromagnetic motors and had two electromagnetic, multi-disk clutches to control output speed. A dynamic model of the system was created which included a direct current electric motor with proportional-integral-derivative (PID) speed control, a two-speed gearbox with dual electromagnetically actuated clutches, and an eddy current dynamometer. A six degree-of-freedom model of the gearbox accounted for the system torsional dynamics and included gear, clutch, shaft, and load inertias as well as shaft flexibilities and a dry clutch stick-slip friction model. Experimental validation tests were performed on the gearbox in the NASA Glenn gear noise test facility. Gearbox output speed and torque as well as drive motor speed and current were compared to those from the analytical predictions. The experiments correlate very well with the predictions, thus validating the dynamic simulation methodologies.

  9. Estimation of longitudinal force, lateral vehicle speed and yaw rate for four-wheel independent driven electric vehicles

    NASA Astrophysics Data System (ADS)

    Chen, Te; Xu, Xing; Chen, Long; Jiang, Haobing; Cai, Yingfeng; Li, Yong

    2018-02-01

    Accurate estimation of longitudinal force, lateral vehicle speed and yaw rate is of great significance to torque allocation and stability control for four-wheel independent driven electric vehicle (4WID-EVs). A fusion method is proposed to estimate the longitudinal force, lateral vehicle speed and yaw rate for 4WID-EVs. The electric driving wheel model (EDWM) is introduced into the longitudinal force estimation, the longitudinal force observer (LFO) is designed firstly based on the adaptive high-order sliding mode observer (HSMO), and the convergence of LFO is analyzed and proved. Based on the estimated longitudinal force, an estimation strategy is then presented in which the strong tracking filter (STF) is used to estimate lateral vehicle speed and yaw rate simultaneously. Finally, co-simulation via Carsim and Matlab/Simulink is carried out to demonstrate the effectiveness of the proposed method. The performance of LFO in practice is verified by the experiment on chassis dynamometer bench.

  10. A study on the relationship between muscle function, functional mobility and level of physical activity in community-dwelling elderly.

    PubMed

    Garcia, Patrícia A; Dias, João M D; Dias, Rosângela C; Santos, Priscilla; Zampa, Camila C

    2011-01-01

    to evaluate the relationship between lower extremity muscle function, calf circumference (CC), handgrip strength (HG), functional mobility and level of physical activity among age groups (65-69, 70-79, 80+) of older adults (men and women) and to identify the best parameter for screening muscle function loss in the elderly. 81 community-dwelling elderly (42 women and 39 men) participated. Walking speed (Multisprint Kit), HG (Jamar dynamometer), hip, knee and ankle muscle function (Biodex isokinetic dynamometer), level of physical activity (Human Activity Profile) and CC (tape measure) were evaluated. ANOVA, Pearson correlation and ROC curves were used for statistical analysis. Dominant CC (34.9±3 vs 37.7±3.6), habitual (1.1±0.2 vs 1.2±0.2) and fast (1.4±0.3 vs 1.7±0.3) walking speed, HG (23.8±7.5 vs 31.8±10.3), average peak torque and average hip, knee and ankle power (p<0.05) were lower for the 80+ group than for the 65-69 year-olds. There were no differences in physical activity level among age groups. Moderate significant correlations were found between muscle function parameters, walking speed and HG; a fair degree of relationship was found between muscle function parameters, CC and level of physical activity (p<0.05). The ROC curve analysis suggested a cutoff point of 14.51 Kgf for screening muscle function loss in elderly women (p=0.03). This study demonstrated an association between muscle function, HG and fast walking speed, a decrease in these parameters with age and the possibility of using HG to screen for muscle function of the lower extremities.

  11. Electric vehicle chassis dynamometer test methods at JPL and their correlation to track tests

    NASA Technical Reports Server (NTRS)

    Marte, J.; Bryant, J.

    1983-01-01

    Early in its electric vehicle (EV) test program, JPL recognized that EV test procedures were too vague and too loosely defined to permit much meaningful data to be obtained from the testing. Therefore, JPL adopted more stringent test procedures and chose the chassis dynamometer rather than the track as its principal test technique. Through the years, test procedures continued to evolve towards a methodology based on chassis dynamometers which would exhibit good correlation with track testing. Based on comparative dynamometer and track test results on the ETV-1 vehicle, the test methods discussed in this report demonstrate a means by which excellent track-to-dynamometer correlation can be obtained.

  12. 40 CFR 1066.215 - Summary of verification and calibration procedures for chassis dynamometers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer... manufacturer instructions and good engineering judgment. (c) Automated dynamometer verifications and... accomplish the verifications and calibrations specified in this subpart. You may use these automated...

  13. 40 CFR 1066.215 - Summary of verification and calibration procedures for chassis dynamometers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer... manufacturer instructions and good engineering judgment. (c) Automated dynamometer verifications and... accomplish the verifications and calibrations specified in this subpart. You may use these automated...

  14. Comparison of Knee and Ankle Dynamometry between NASA's X1 Exoskeleton and Biodex System 4

    NASA Technical Reports Server (NTRS)

    English, K. L.; Newby, N. J.; Hackney, K. J.; DeWitt, J. K.; Beck, C. E.; Rovekamp, R. N.; Rea, R. L.; Ploutz-Snyder, L. L.

    2014-01-01

    Pre- and post-flight dynamometry is performed on International Space Station crewmembers to characterize microgravity-induced strength changes. Strength is not assessed in flight due to hardware limitations and there is poor understanding of the time course of in-flight changes. PURPOSE: To assess the reliability of a prototype dynamometer, the X1 Exoskeleton (EXO) and its agreement with a Biodex System 4 (BIO). METHODS: Eight subjects (4 M/4 F) completed 2 counterbalanced testing sessions of knee extension/flexion (KE/KF), 1 with BIO and 1 with EXO, with repeated measures within each session in normal gravity. Test-retest reliability (test 1 and 2) and device agreement (BIO vs. EXO) were evaluated. Later, to assess device agreement for ankle plantarflexion (PF), 10 subjects (4 M/6 F) completed 3 test conditions (BIO, EXO, and BIOEXO); BIOEXO was a hybrid condition comprised of the Biodex dynamometer motor and the X1 footplate and ankle frame. Ankle comparisons were: BIO vs. BIOEXO (footplate differences), BIOEXO vs. EXO (motor differences), and BIO vs. EXO (all differences). Reliability for KE/KF was determined by intraclass correlation (ICC). Device agreement was assessed with: 1) repeated measures ANOVA, 2) a measure of concordance (rho), and 3) average difference. RESULTS: ICCs for KE/KF were 0.99 for BIO and 0.96 to 0.99 for EXO. Agreement was high for KE (concordance: 0.86 to 0.95; average differences: -7 to +9 Nm) and low to moderate for KF (concordance: 0.64 to 0.78; average differences: -4 to -29 Nm, P<0.05). BIO vs. BIOEXO PF concordance ranged from 0.89 to 0.92 and mean differences ranged from -9 to +3 Nm (BIO < BIOEXO). BIOEXO vs. EXO PF concordance ranged from 0.73 to 0.80 while mean differences were -18 to -36 Nm (BIOEXO < EXO, P<0.05). PF concordance for BIO vs. EXO was slightly lower (0.61 to 0.84) and mean differences were greater (-27 to -33 Nm; BIO < EXO, P<0.05). CONCLUSION: BIO and EXO were similarly reliable for KE and KF. KE measures produced high agreement between devices; KF did not. For ankle PF, torque differences due to the two footplates were small. However, the X1 motor reports greater torques than the Biodex motor during PF. This first prototype provides proof of concept for a reliable, robotic-based exoskeleton to perform portable dynamometry for large muscle groups of the lower body.

  15. 21 CFR 888.1250 - Nonpowered dynamometer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonpowered dynamometer. 888.1250 Section 888.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1250 Nonpowered dynamometer. (a...

  16. 21 CFR 888.1250 - Nonpowered dynamometer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nonpowered dynamometer. 888.1250 Section 888.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1250 Nonpowered dynamometer. (a...

  17. 21 CFR 888.1250 - Nonpowered dynamometer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nonpowered dynamometer. 888.1250 Section 888.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1250 Nonpowered dynamometer. (a...

  18. 21 CFR 888.1250 - Nonpowered dynamometer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonpowered dynamometer. 888.1250 Section 888.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1250 Nonpowered dynamometer. (a...

  19. 21 CFR 888.1250 - Nonpowered dynamometer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nonpowered dynamometer. 888.1250 Section 888.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1250 Nonpowered dynamometer. (a...

  20. 40 CFR 610.61 - Engine dynamometer tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...

  1. 40 CFR 610.61 - Engine dynamometer tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...

  2. 40 CFR 610.61 - Engine dynamometer tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...

  3. 40 CFR 610.61 - Engine dynamometer tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...

  4. 40 CFR 610.61 - Engine dynamometer tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...

  5. 40 CFR 1066.210 - Dynamometers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... to recreate the mechanical inertia and frictional forces that a vehicle exerts on road surfaces... drive axles may share a single drive roll. Use good engineering judgment to ensure that the dynamometer... engineering judgment. (3) The load applied by the dynamometer simulates forces acting on the vehicle during...

  6. The effect of 3 torque delivery systems on gold screw preload at the gold cylinder-abutment screw joint.

    PubMed

    Tan, Keson B; Nicholls, Jack I

    2002-01-01

    This study measured the gold screw preload at the gold cylinder-abutment screw joint interface obtained by 3 torque delivery systems. Using a precalibrated, strain-gauged standard abutment as the load cell, 3 torque delivery systems tested were shown to have significant differences in gold screw preload when a gold cylinder was attached. Mean preloads measured were 291.2 N for hand torque drivers set at 10 Ncm, 340.3 N for electronic torque controllers at low setting/10 Ncm, 384.4 N for electronic torque controllers at high setting/10 Ncm; and 140.8 N for hand-tightening with a prosthetic slot screwdriver. Significant differences in screw preload were also found between operators using a hand torque driver. Hand-tightening delivered insufficient preload and cannot be recommended for final gold screw tightening. Different electronic torque controller units set at 10 Ncm induced mean gold screw preloads that ranged from 264.1 N to as high as 501.2 N. Electronic torque controllers should be regularly recalibrated to ensure optimal output.

  7. Criterion and Construct Validity of an Isometric Midthigh-Pull Dynamometer for Assessing Whole-Body Strength in Professional Rugby League Players.

    PubMed

    Dobbin, Nick; Hunwicks, Richard; Jones, Ben; Till, Kevin; Highton, Jamie; Twist, Craig

    2018-02-01

    To examine the criterion and construct validity of an isometric midthigh-pull dynamometer to assess whole-body strength in professional rugby league players. Fifty-six male rugby league players (33 senior and 23 youth players) performed 4 isometric midthigh-pull efforts (ie, 2 on the dynamometer and 2 on the force platform) in a randomized and counterbalanced order. Isometric peak force was underestimated (P < .05) using the dynamometer compared with the force platform (95% LoA: -213.5 ± 342.6 N). Linear regression showed that peak force derived from the dynamometer explained 85% (adjusted R 2  = .85, SEE = 173 N) of the variance in the dependent variable, with the following prediction equation derived: predicted peak force = [1.046 × dynamometer peak force] + 117.594. Cross-validation revealed a nonsignificant bias (P > .05) between the predicted and peak force from the force platform and an adjusted R 2 (79.6%) that represented shrinkage of 0.4% relative to the cross-validation model (80%). Peak force was greater for the senior than the youth professionals using the dynamometer (2261.2 ± 222 cf 1725.1 ± 298.0 N, respectively; P < .05). The isometric midthigh pull assessed using a dynamometer underestimates criterion peak force but is capable of distinguishing muscle-function characteristics between professional rugby league players of different standards.

  8. Temperature Dependences of Torque Generation and Membrane Voltage in the Bacterial Flagellar Motor

    PubMed Central

    Inoue, Yuichi; Baker, Matthew A.B.; Fukuoka, Hajime; Takahashi, Hiroto; Berry, Richard M.; Ishijima, Akihiko

    2013-01-01

    In their natural habitats bacteria are frequently exposed to sudden changes in temperature that have been shown to affect their swimming. With our believed to be new methods of rapid temperature control for single-molecule microscopy, we measured here the thermal response of the Na+-driven chimeric motor expressed in Escherichia coli cells. Motor torque at low load (0.35 μm bead) increased linearly with temperature, twofold between 15°C and 40°C, and torque at high load (1.0 μm bead) was independent of temperature, as reported for the H+-driven motor. Single cell membrane voltages were measured by fluorescence imaging and these were almost constant (∼120 mV) over the same temperature range. When the motor was heated above 40°C for 1–2 min the torque at high load dropped reversibly, recovering upon cooling below 40°C. This response was repeatable over as many as 10 heating cycles. Both increases and decreases in torque showed stepwise torque changes with unitary size ∼150 pN nm, close to the torque of a single stator at room temperature (∼180 pN nm), indicating that dynamic stator dissociation occurs at high temperature, with rebinding upon cooling. Our results suggest that the temperature-dependent assembly of stators is a general feature of flagellar motors. PMID:24359752

  9. 40 CFR 1066.410 - Dynamometer test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... drive mode. (For purposes of this paragraph (g), the term four-wheel drive includes other multiple drive... Dynamometer test procedure. (a) Dynamometer testing may consist of multiple drive cycles with both cold-start...-setting part identifies the driving schedules and the associated sample intervals, soak periods, engine...

  10. 21 CFR 888.1240 - AC-powered dynamometer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false AC-powered dynamometer. 888.1240 Section 888.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1240 AC-powered dynamometer. (a...

  11. 21 CFR 888.1240 - AC-powered dynamometer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false AC-powered dynamometer. 888.1240 Section 888.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1240 AC-powered dynamometer. (a...

  12. 21 CFR 888.1240 - AC-powered dynamometer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false AC-powered dynamometer. 888.1240 Section 888.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1240 AC-powered dynamometer. (a...

  13. 40 CFR 86.1237-96 - Dynamometer runs.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Dynamometer runs. 86.1237-96 Section 86.1237-96 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Methanol-Fueled Heavy-Duty Vehicles § 86.1237-96 Dynamometer runs. Section 86.1237-96 includes text that...

  14. 40 CFR 86.1237-96 - Dynamometer runs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Dynamometer runs. 86.1237-96 Section 86.1237-96 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Methanol-Fueled Heavy-Duty Vehicles § 86.1237-96 Dynamometer runs. Section 86.1237-96 includes text that...

  15. 40 CFR 1066.270 - Unloaded coastdown verification.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... manufacturer. (2) With the dynamometer in coastdown mode, set the dynamometer inertia for the smallest vehicle... with the dynamometer inertia set for the largest vehicle weight that you expect to test. (4) Determine the average coastdown force, F, for each speed and inertia setting using the following equation...

  16. 40 CFR 1066.270 - Unloaded coastdown verification.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... manufacturer. (2) With the dynamometer in coastdown mode, set the dynamometer inertia for the smallest vehicle... with the dynamometer inertia set for the largest vehicle weight that you expect to test. (4) Determine the average coastdown force, F, for each speed and inertia setting using the following equation...

  17. A comparison of torque expression between stainless steel, titanium molybdenum alloy, and copper nickel titanium wires in metallic self-ligating brackets.

    PubMed

    Archambault, Amy; Major, Thomas W; Carey, Jason P; Heo, Giseon; Badawi, Hisham; Major, Paul W

    2010-09-01

    The force moment providing rotation of the tooth around the x-axis (buccal-lingual) is referred to as torque expression in orthodontic literature. Many factors affect torque expression, including the wire material characteristics. This investigation aims to provide an experimental study into and comparison of the torque expression between wire types. With a worm-gear-driven torquing apparatus, wire was torqued while a bracket mounted on a six-axis load cell was engaged. Three 0.019 x 0.0195 inch wire (stainless steel, titanium molybdenum alloy [TMA], copper nickel titanium [CuNiTi]), and three 0.022 inch slot bracket combinations (Damon 3MX, In-Ovation-R, SPEED) were compared. At low twist angles (<12 degrees), the differences in torque expression between wires were not statistically significant. At twist angles over 24 degrees, stainless steel wire yielded 1.5 to 2 times the torque expression of TMA and 2.5 to 3 times that of nickel titanium (NiTi). At high angles of torsion (over 40 degrees) with a stiff wire material, loss of linear torque expression sometimes occurred. Stainless steel has the largest torque expression, followed by TMA and then NiTi.

  18. Magnification of starting torques of dc motors by maximum power point trackers in photovoltaic systems

    NASA Technical Reports Server (NTRS)

    Appelbaum, J.; Singer, S.

    1989-01-01

    A calculation of the starting torque ratio of permanent magnet, series, and shunt-excited dc motors powered by solar cell arrays is presented for two cases, i.e., with and without a maximum-power-point tracker (MPPT). Defining motor torque magnification by the ratio of the motor torque with an MPPT to the motor torque without an MPPT, a magnification of 3 for the permanent magnet motor and a magnification of 7 for both the series and shunt motors are obtained. The study also shows that all motor types are less sensitive to solar insolation variation in systems including MPPTs as compared to systems without MPPTs.

  19. 40 CFR 86.1218-85 - Dynamometer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the power absorption unit. The dynamometer is driven above the test speed range. The device used to... coastdown. The kinetic energy of the system is dissipated by the dynamometer. This method neglects the... with paired rolls, the inertia and power absorption of the free (rear) roll may be neglected if its...

  20. 40 CFR 86.1218-85 - Dynamometer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the power absorption unit. The dynamometer is driven above the test speed range. The device used to... coastdown. The kinetic energy of the system is dissipated by the dynamometer. This method neglects the... with paired rolls, the inertia and power absorption of the free (rear) roll may be neglected if its...

  1. 40 CFR 86.1218-85 - Dynamometer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the power absorption unit. The dynamometer is driven above the test speed range. The device used to... coastdown. The kinetic energy of the system is dissipated by the dynamometer. This method neglects the... with paired rolls, the inertia and power absorption of the free (rear) roll may be neglected if its...

  2. 40 CFR 86.1218-85 - Dynamometer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the power absorption unit. The dynamometer is driven above the test speed range. The device used to... coastdown. The kinetic energy of the system is dissipated by the dynamometer. This method neglects the... with paired rolls, the inertia and power absorption of the free (rear) roll may be neglected if its...

  3. 40 CFR 86.215-94 - EPA urban dynamometer driving schedule.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false EPA urban dynamometer driving schedule. 86.215-94 Section 86.215-94 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.215-94 EPA urban dynamometer...

  4. 40 CFR 86.118-00 - Dynamometer calibrations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1977 and Later Model Year New Light-Duty Vehicles and New Light-Duty Trucks and New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.118-00 Dynamometer calibrations. (a) The dynamometer shall be...

  5. 40 CFR 86.118-00 - Dynamometer calibrations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1977 and Later Model Year New Light-Duty Vehicles and New Light-Duty Trucks and New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.118-00 Dynamometer calibrations. (a) The dynamometer shall be...

  6. 40 CFR 1066.235 - Speed verification procedure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... before testing, and after major maintenance. (c) Procedure. Use one of the following procedures to verify... dynamometer control circuits. Determine the speed error as follows: (i) Set the dynamometer to speed-control mode. Set the dynamometer speed to a value between 4.2 m/s and the maximum speed expected during...

  7. 40 CFR 86.1334-84 - Pre-test engine and dynamometer preparation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Pre-test engine and dynamometer preparation. 86.1334-84 Section 86.1334-84 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Exhaust Test Procedures § 86.1334-84 Pre-test engine and dynamometer preparation. (a) Control system...

  8. 40 CFR 86.1334-84 - Pre-test engine and dynamometer preparation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Pre-test engine and dynamometer preparation. 86.1334-84 Section 86.1334-84 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Exhaust Test Procedures § 86.1334-84 Pre-test engine and dynamometer preparation. (a) Control system...

  9. 40 CFR 86.1334-84 - Pre-test engine and dynamometer preparation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Pre-test engine and dynamometer preparation. 86.1334-84 Section 86.1334-84 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Exhaust Test Procedures § 86.1334-84 Pre-test engine and dynamometer preparation. (a) Control system...

  10. 40 CFR 86.1334-84 - Pre-test engine and dynamometer preparation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Pre-test engine and dynamometer preparation. 86.1334-84 Section 86.1334-84 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Exhaust Test Procedures § 86.1334-84 Pre-test engine and dynamometer preparation. (a) Control system...

  11. 40 CFR 1066.270 - Unloaded coastdown verification.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... manufacturer. (2) With the dynamometer in coastdown mode, set the dynamometer inertia for the smallest vehicle...)(2) of this section with the dynamometer inertia and road-load coefficients set for the largest... inertia setting for each of the coastdowns performed using the following equation: ER28AP14.078 Where: F...

  12. Low back and lower-limb muscle performance in male and female recreational runners with chronic low back pain.

    PubMed

    Cai, Congcong; Kong, Pui W

    2015-06-01

    Controlled laboratory study, cross-sectional. To compare lumbar extensor muscle fatigability, lumbar stabilizing muscle activation, and lower-limb strength between male and female runners with chronic low back pain (LBP) and healthy runners. Little is known about muscle performance in runners with chronic LBP. Eighteen recreational runners with chronic LBP (9 men, 9 women; mean age, 27.8 years) and 18 healthy recreational runners (9 men, 9 women; mean age, 24.6 years) were recruited. The median frequency slopes for bilateral iliocostalis and longissimus were calculated from electromyographic signals captured during a 2-minute Sorensen test. The thickness changes of the transversus abdominis and lumbar multifidus between resting and contraction were measured using an ultrasound scanner. Peak concentric torques of the bilateral hip extensors, hip abductors, and knee extensors were measured using an isokinetic dynamometer at 60°/s. The average values for both sides were used for statistical analysis. When averaged across sexes, peak knee extensor torque was 12.2% lower in the LBP group compared to the healthy group (mean difference, 0.29 Nm/kg; 95% confidence interval: 0.06, 0.53; P = .016). Male runners with chronic LBP exhibited smaller lumbar multifidus thickness changes compared to healthy male runners (mean difference, 0.13 cm; 95% confidence interval: 0.01, 0.25; P = .033). No other group differences were observed. Runners with chronic LBP exhibited diminished knee extensor strength compared to healthy runners. Male runners with chronic LBP demonstrated additional deficits in lumbar multifidus activation.

  13. Isokinetic profile of elbow flexion and extension strength in elite junior tennis players.

    PubMed

    Ellenbecker, Todd S; Roetert, E Paul

    2003-02-01

    Descriptive study. To determine whether bilateral differences exist in concentric elbow flexion and extension strength in elite junior tennis players. The repetitive nature of tennis frequently produces upper extremity overuse injuries. Prior research has identified tennis-specific strength adaptation in the dominant shoulder and distal upper extremity musculature of elite players. No previous study has addressed elbow flexion and extension strength. Thirty-eight elite junior tennis players were bilaterally tested for concentric elbow flexion and extension muscle performance on a Cybex 6000 isokinetic dynamometer at 90 degrees/s, 210 degrees/s, and 300 degrees/s. Repeated-measures ANOVAs were used to test for differences between extremities, muscle groups, and speed. Significantly greater (P<0.002) dominant-arm elbow extension peak torque values were measured at 90 degrees/s, 210 degrees/s, and 300 degrees/s for males. Significantly greater (P<0.002) dominant-arm single-repetition work values were also measured at 90 degrees/s and 210 degrees/s for males. No significant difference was measured between extremities in elbow flexion muscular performance in males and for elbow flexion or extension peak torque and single-repetition work values in females. No significant difference between extremities was measured in elbow flexion/extension strength ratios in females and significant differences between extremities in this ratio were only present at 210 degrees/s in males (P<0.002). These data indicate muscular adaptations around the dominant elbow in male elite junior tennis players but not females. These data have ramifications for clinicians rehabilitating upper extremity injuries in patients from this population.

  14. Attenuation of indirect markers of eccentric exercise-induced muscle damage by curcumin.

    PubMed

    Tanabe, Yoko; Maeda, Seiji; Akazawa, Nobuhiko; Zempo-Miyaki, Asako; Choi, Youngju; Ra, Song-Gyu; Imaizumi, Atsushi; Otsuka, Yoshihiko; Nosaka, Kazunori

    2015-09-01

    Polyphenolic curcumin is known to have potent anti-inflammatory effects; thus the present study investigated the hypothesis that curcumin ingestion would attenuate muscle damage after eccentric exercise. Fourteen untrained young men (24 ± 1 years) performed 50 maximal isokinetic (120°/s) eccentric contractions of the elbow flexors of one arm on an isokinetic dynamometer and the same exercise with the other arm 4 weeks later. They took 150 mg of curcumin (theracurmin) or placebo (starch) orally before and 12 h after each eccentric exercise bout in a randomised, crossover design. Maximal voluntary contraction (MVC) torque of the elbow flexors, range of motion of the elbow joint, upper-arm circumference, muscle soreness, serum creatine kinase (CK) activity, and plasma interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) concentration were measured before, immediately after, and 24, 48, 72 and 96 h after each eccentric exercise. Changes in these variables over time were compared between curcumin and placebo conditions by two-way repeated measures ANOVA. MVC torque decreased smaller and recovered faster (e.g., 4 days post-exercise: -31 ± 13 % vs. -15 ± 15 %), and peak serum CK activity was smaller (peak: 7684 ± 8959 IU/L vs. 3398 ± 3562 IU/L) for curcumin than placebo condition (P < 0.05). However, no significant differences between conditions were evident for other variables, and no significant changes in IL-6 and TNF-α were evident after exercise. It is concluded that theracurmin ingestion attenuates some aspects of muscle damage such as MVC loss and CK activity increase.

  15. Selective hypertrophy of the quadriceps musculature after 14 weeks of isokinetic and conventional resistance training.

    PubMed

    Matta, Thiago Torres; Nascimento, Francisco Xavier; Trajano, Gabriel S; Simão, Roberto; Willardson, Jeffrey Michael; Oliveira, Liliam Fernandes

    2017-03-01

    One of the fundamental adaptations observed with resistance training (RT) is muscle hypertrophy. Conventional and isokinetic machines provide different forms of mechanical stress, and it is possible that these two training modes could promote differing degrees of hypertrophic adaptations. There is a lack of data comparing the selective hypertrophy of the quadriceps musculature after training with a conventional knee extension machine versus an isokinetic machine. The purpose of this study was to evaluate the selective hypertrophy of the quadriceps musculature and knee extension maximal isometric torque after 14 weeks of conventional versus isokinetic RT. Thirty-five men were assigned to three groups: control group and training groups (conventional and isokinetic) performed three sets of unilateral knee extensions per session with a progressive loading scheme twice a week. Prior to and following the intervention, maximal isometric knee extensor torque was measured using an isokinetic dynamometer, and muscle thickness (MT) of quadriceps femoris muscles was assessed via ultrasound. The results indicated non-uniform changes in MT between the muscles that comprise the quadriceps femoris group. For the conventional group, significantly greater increases in rectus femoris thickness were evident versus all other quadriceps muscles (14%). For the isokinetic group, increases in RF thickness (11%) were significantly greater in comparison with the vastus intermedius only. Although the muscle thickness did not increase for all the quadriceps femoris muscles, the relative rectus femoris adaptation suggested a selective hypertrophy favouring this portion. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  16. Strength deficit of knee flexors is dependent on hip position in adults with chronic hemiparesis.

    PubMed

    Michaelsen, Stella M; Ovando, Angélica C; Bortolotti, Adriano; Bandini, Bruno

    2013-01-01

    The extent to which muscle length affects force production in paretic lower limb muscles after stroke in comparison to controls has not been established. To investigate knee flexor strength deficits dependent on hip joint position in adults with hemiparesis and compare with healthy controls. a cross-sectional study with ten subjects with chronic (63±40 months) hemiparesis with mild to moderate lower limb paresis (Fugl-Meyer score 26±3) and 10 neurologically healthy controls. Isometric knee flexion strength with the hip positioned at 90° and 0° of flexion was assessed randomly on the paretic and non-paretic side of hemiparetic subjects and healthy controls. Subjects were asked to perform a maximal isometric contraction sustained for four seconds and measured by a dynamometer. The ratio of knee flexor strength between these two hip positions was calculated: Hip 0°/Hip 90°. Also, locomotor capacity was evaluated by the timed up and go test and by walking velocity over 10 meters. In subjects with hemiparesis, absolute knee flexion torque decreased (p<0.001) with the hip in extension (at 0°). The ratio of knee flexor torque Hip 0°/Hip 90° on the paretic side in hemiparetics was lower than in controls (p=0.02). Weakness dependent on joint position is more significant in the paretic lower limb of adults with hemiparesis when compared to controls. More attention should be given to lower limb muscle strengthening exercises in individuals with stroke, with emphasis on the strengthening exercises in positions in which the muscle is shortened.

  17. Gravity and positional homeostasis of the cell

    NASA Technical Reports Server (NTRS)

    Nace, G. W.

    1983-01-01

    The effect of gravity upon cytoplasmic aggregates of the size present in eggs and upon cells is investigated. An expression is developed to describe the tendency of torque to rotate the egg and reorganize its constituents. This expression provides the net torque resulting from buoyancy and gravity acting upon a dumbbell-shaped cell, with heavy and light masses at either end and floating in a medium. Torques of approximately 2.5 x 10 to the -13th to 0.85 dyne-cm are found to act upon cells ranging from 6.4 microns to 31 mm (chicken egg). It is noted that cells must expend energy to maintain positional homeostasis against gravity, as demonstrated by results from Skylab 3, where tissue cultures used 58 percent more glucose on earth than in space. The implications for developmental biology, physiology, genetics, and evolution are discussed. It is argued that at the cellular and tissue levels the concept of gravity receptors may be unnecessary.

  18. 40 CFR 86.137-90 - Dynamometer test run, gaseous and particulate emissions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... filters to the weighing chamber for post-test conditioning, if applicable. (22) Disconnect the exhaust... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Dynamometer test run, gaseous and... New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.137-90 Dynamometer test run, gaseous...

  19. 40 CFR 86.137-90 - Dynamometer test run, gaseous and particulate emissions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... filters to the weighing chamber for post-test conditioning, if applicable. (22) Disconnect the exhaust... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Dynamometer test run, gaseous and... New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.137-90 Dynamometer test run, gaseous...

  20. 40 CFR 86.137-90 - Dynamometer test run, gaseous and particulate emissions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... filters to the weighing chamber for post-test conditioning, if applicable. (22) Disconnect the exhaust... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Dynamometer test run, gaseous and... New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.137-90 Dynamometer test run, gaseous...

  1. 40 CFR 86.137-90 - Dynamometer test run, gaseous and particulate emissions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... filters to the weighing chamber for post-test conditioning, if applicable. (22) Disconnect the exhaust... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Dynamometer test run, gaseous and... New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.137-90 Dynamometer test run, gaseous...

  2. 40 CFR 86.137-94 - Dynamometer test run, gaseous and particulate emissions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... filters to the weighing chamber for post-test conditioning, if applicable. (22) Disconnect the exhaust... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Dynamometer test run, gaseous and... New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.137-94 Dynamometer test run, gaseous...

  3. 40 CFR 86.135-12 - Dynamometer procedure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... control of pre-selectable power settings may be set anytime prior to the beginning of the emissions test... Heavy-Duty Vehicles; Test Procedures § 86.135-12 Dynamometer procedure. (a) Overview. The dynamometer run consists of two tests, a “cold” start test, after a minimum 12-hour and a maximum 36-hour soak...

  4. 40 CFR 86.135-12 - Dynamometer procedure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... control of pre-selectable power settings may be set anytime prior to the beginning of the emissions test... Heavy-Duty Vehicles; Test Procedures § 86.135-12 Dynamometer procedure. (a) Overview. The dynamometer run consists of two tests, a “cold” start test, after a minimum 12-hour and a maximum 36-hour soak...

  5. 40 CFR 86.1237-85 - Dynamometer runs.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Dynamometer runs. 86.1237-85 Section... Methanol-Fueled Heavy-Duty Vehicles § 86.1237-85 Dynamometer runs. (a) The vehicle shall be either driven... the diurnal loss test and beginning of the hot soak preparation run shall not exceed 3 minutes, and...

  6. 40 CFR 86.137-96 - Dynamometer test run, gaseous and particulate emissions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Dynamometer test run, gaseous and particulate emissions. 86.137-96 Section 86.137-96 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.137-96 Dynamometer test run, gaseous...

  7. 40 CFR 86.137-96 - Dynamometer test run, gaseous and particulate emissions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Dynamometer test run, gaseous and particulate emissions. 86.137-96 Section 86.137-96 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.137-96 Dynamometer test run, gaseous...

  8. 40 CFR 86.884-7 - Dynamometer operation cycle for smoke emission tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Dynamometer operation cycle for smoke... Dynamometer operation cycle for smoke emission tests. (a) The following sequence of operations shall be... the preconditioning prior to the smoke cycle. (ii) With the throttle remaining in the fully open...

  9. Small-Bolt Torque-Tension Tester

    NASA Technical Reports Server (NTRS)

    Posey, Alan J.

    2009-01-01

    The device described here measures the torque-tension relationship for fasteners as small as #0. The small-bolt tester consists of a plate of high-strength steel into which three miniature load cells are recessed. The depth of the recess is sized so that the three load cells can be shimmed, the optimum height depending upon the test hardware. The three miniature load cells are arranged in an equilateral triangular configuration with the test bolt aligned with the centroid of the three. This is a kinematic arrangement.

  10. TTI (Texas Transportation Institute) track/dynamometer study. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reineman, M.; Thompson, G.

    1983-01-01

    Seven passenger cars and one light truck were operated over the EPA urban and highway driving cycles to compare fuel economy measurements obtained on a test track with the fuel economy results obtained on a chassis dynamometer. The test program was designed to duplicate, as closely as possible, the track force loading (as determined by standard EPA road coastdown procedures) on the dynamometer. Experimental parameters which were investigated included loading differences between front- and rear-wheel drive vehicles, volumetric versus carbon balance fuel measurement techniques, coupled versus uncoupled roll dynamometer tests, and curved track versus straight track coastdowns.

  11. 40 CFR 86.1215-85 - EPA heavy-duty vehicle (HDV) urban dynamometer driving schedule.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false EPA heavy-duty vehicle (HDV) urban..., Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.1215-85 EPA heavy-duty vehicle (HDV) urban dynamometer driving schedule. (a)(1) The EPA dynamometer driving schedule for heavy-duty...

  12. 40 CFR 86.884-7 - Dynamometer operation cycle for smoke emission tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... provide the speed and load necessary to comply with the heavy-duty “curb idle” definition per § 86.084-2..., and held in, the fully open position. The inertia of the engine and the dynamometer, or alternately a... mode, motoring assist may be used to offset excessive dynamometer inertia load when necessary. No...

  13. 40 CFR 86.884-7 - Dynamometer operation cycle for smoke emission tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... be set to provide the speed and load necessary to comply with the heavy-duty “curb idle” definition..., and held in, the fully open position. The inertia of the engine and the dynamometer, or alternately a... mode, motoring assist may be used to offset excessive dynamometer inertia load when necessary. No...

  14. 40 CFR 86.884-7 - Dynamometer operation cycle for smoke emission tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... be set to provide the speed and load necessary to comply with the heavy-duty “curb idle” definition..., and held in, the fully open position. The inertia of the engine and the dynamometer, or alternately a... mode, motoring assist may be used to offset excessive dynamometer inertia load when necessary. No...

  15. 40 CFR 86.884-7 - Dynamometer operation cycle for smoke emission tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... be set to provide the speed and load necessary to comply with the heavy-duty “curb idle” definition..., and held in, the fully open position. The inertia of the engine and the dynamometer, or alternately a... mode, motoring assist may be used to offset excessive dynamometer inertia load when necessary. No...

  16. Newton vs. Munchhausen in upper-troposphere dynamics

    NASA Astrophysics Data System (ADS)

    Bergmann, Juan Carlos

    2010-05-01

    Atmospheric angular momentum (AM) balance depends crucially on the existence and magnitude of the planetary-scale AM transport by 'eddies' in the upper troposphere. Its divergence has to provide the torque, which is necessary to realise the upper-troposphere branch of meridional circulation. (In the boundary layer, the torque is provided by surface-friction.) The torques in neighbouring circulation cells are opposed, so that the AM transport mediates a torque-interaction between the circulation cells. This interaction corresponds to a clear requirement of Newton's Third Law: torques (forces) exist only in interaction with other bodies, and their sum is equal to zero. In Münchhausen's physics, force (and torque) exists without interaction: In a famous tale, Münchhausen saves himself (and his horse!) from drowning in a swamp-hole by pulling himself up at his hair. Münchhausen-physics situations arise in the dynamical analysis of the torque exerted by a single eddy and in analysis of the cause for the AM transport of the single eddy. The local AM transport of the single eddy is defined by the difference in zonal velocity between the pole-ward and equator-ward branches (Δu) multiplied with meridional velocity-magnitude (¦v¦). For the average over many eddies, it transforms to the average product of the deviations of zonal and meridional velocities from their local averages (, eddy-correlation; the complete formulations include the local radius of rotation but it is omitted here for simplicity reasons). This definition is phenomenological but not dynamical. In dynamical analysis it turns out that the torque-related zonal equation of motion of an AM-transporting single eddy can be formulated without torque-interaction with other bodies (torque-free eddy). Newton III implies also the phenomenological torque (transport divergence -δ(¦v¦Δu)/δy) to be zero for this case because there is no partner of torque-interaction. However, the dynamically torque-free single eddy has an unavoidable 'transport' divergence - especially in the turning-region of the meridional motion. Thus, there is a phenomenological 'torque' (non-zero 'transport' divergence) without torque-interaction - a classical Münchhausen situation! The dynamical cause of phenomenological 'AM transport' and associated phenomenological 'torques' of the dynamically torque-free single eddy is 'hidden' in the non-torque-related meridional equation of motion for steady-state: δv-δ t = - u δv-δx - vδv-δ y - f u(x) + Fy(x) = 0 . Strong variation of the meridional pressure-gradient force Fy(x) (no torque!) over the eddy-path (longitude x) produces varying zonal velocities u(x) that are falsely interpreted as 'AM transport' on the phenomenological level (the 'advective' terms are negligible outside the eddy's turning regions). Thus, creation and destruction of phenomenological 'AM transport' (Δu) in a single eddy do not originate from torque-interaction with other bodies - another classical Münchhausen situation! Should the previous analysis be ignored in favour of maintaining the 'established' ideas of upper-troposphere dynamics or should there be an effort to formulate new ideas that are in accordance with Newtonian physics?

  17. Hardware-in-the-Loop Testing of Utility-Scale Wind Turbine Generators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schkoda, Ryan; Fox, Curtiss; Hadidi, Ramtin

    2016-01-26

    Historically, wind turbine prototypes were tested in the field, which was--and continues to be--a slow and expensive process. As a result, wind turbine dynamometer facilities were developed to provide a more cost-effective alternative to field testing. New turbine designs were tested and the design models were validated using dynamometers to drive the turbines in a controlled environment. Over the years, both wind turbine dynamometer testing and computer technology have matured and improved, and the two are now being joined to provide hardware-in-the-loop (HIL) testing. This type of testing uses a computer to simulate the items that are missing from amore » dynamometer test, such as grid stiffness, voltage, frequency, rotor, and hub. Furthermore, wind input and changing electric grid conditions can now be simulated in real time. This recent advance has greatly increased the utility of dynamometer testing for the development of wind turbine systems.« less

  18. Effectiveness of the surgical torque limiter: a model comparing drill- and hand-based screw insertion into locking plates.

    PubMed

    Ioannou, Christopher; Knight, Matthew; Daniele, Luca; Flueckiger, Lee; Tan, Ezekiel S L

    2016-10-17

    The objective of this study is to analyse the effectiveness of the surgical torque limiter during operative use. The study also investigates the potential differences in torque between hand and drill-based screw insertion into locking plates using a standardised torque limiter. Torque for both hand and power screw insertion was measured through a load cell, registering 6.66 points per second. This was performed in a controlled environment using synthetic bone, a locking plate and locking screws to simulate plate fixation. Screws were inserted by hand and by drill with torque values measured. The surgical torque limiter (1.5 Nm) was effective as the highest recorded reading in the study was 1.409 Nm. Comparatively, there is a statistically significant difference between screw insertion methods. Torque produced for manually driven screw insertion into locking plates was 1.289 Nm (95 % CI 1.269-1.308) with drill-powered screw insertion at 0.740 Nm (95 % CI 0.723-0.757). The surgical torque limiter proved to be effective as per product specifications. Screws inserted under power produce significantly less torque when compared to manual insertion by hand. This is likely related to the mechanism of the torque limiter when being used at higher speeds for which it was designed. We conclude that screws may be inserted using power to the plate with the addition of a torque limiter. It is recommended that all screws inserted by drill be hand tightened to achieve adequate torque values.

  19. NREL Bridges Fuels and Engines R&D to Maximize Vehicle Efficiency and

    Science.gov Websites

    innovation-from fuel chemistry, conversion, and combustion to the evaluation of advanced fuels in actual -cylinder engine for advanced compression ignition fuels research will be installed and commissioned in the vehicle performance and emissions research, two engine dynamometer test cells for advanced fuels research

  20. Two-Finger Tightness: What Is It? Measuring Torque and Reproducibility in a Simulated Model.

    PubMed

    Acker, William B; Tai, Bruce L; Belmont, Barry; Shih, Albert J; Irwin, Todd A; Holmes, James R

    2016-05-01

    Residents in training are often directed to insert screws using "two-finger tightness" to impart adequate torque but minimize the chance of a screw stripping in bone. This study seeks to quantify and describe two-finger tightness and to assess the variability of its application by residents in training. Cortical bone was simulated using a polyurethane foam block (30-pcf density) that was prepared with predrilled holes for tightening 3.5 × 14-mm long cortical screws and mounted to a custom-built apparatus on a load cell to capture torque data. Thirty-three residents in training, ranging from the first through fifth years of residency, along with 8 staff members, were directed to tighten 6 screws to two-finger tightness in the test block, and peak torque values were recorded. The participants were blinded to their torque values. Stripping torque (2.73 ± 0.56 N·m) was determined from 36 trials and served as a threshold for failed screw placement. The average torques varied substantially with regard to absolute torque values, thus poorly defining two-finger tightness. Junior residents less consistently reproduced torque compared with other groups (0.29 and 0.32, respectively). These data quantify absolute values of two-finger tightness but demonstrate considerable variability in absolute torque values, percentage of stripping torque, and ability to consistently reproduce given torque levels. Increased years in training are weakly correlated with reproducibility, but experience does not seem to affect absolute torque levels. These results question the usefulness of two-finger tightness as a teaching tool and highlight the need for improvement in resident motor skill training and development within a teaching curriculum. Torque measuring devices may be a useful simulation tools for this purpose.

  1. 40 CFR 86.135-12 - Dynamometer procedure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Heavy-Duty Vehicles; Test Procedures § 86.135-12 Dynamometer procedure. (a) Overview. The dynamometer run consists of two tests, a “cold” start test, after a minimum 12-hour and a maximum 36-hour soak according to the provisions of §§ 86.132 and 86.133, and a “hot” start test following the “cold” start by 10...

  2. 40 CFR 86.135-12 - Dynamometer procedure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Heavy-Duty Vehicles; Test Procedures § 86.135-12 Dynamometer procedure. (a) Overview. The dynamometer run consists of two tests, a “cold” start test, after a minimum 12-hour and a maximum 36-hour soak according to the provisions of §§ 86.132 and 86.133, and a “hot” start test following the “cold” start by 10...

  3. 40 CFR 86.135-12 - Dynamometer procedure.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Heavy-Duty Vehicles; Test Procedures § 86.135-12 Dynamometer procedure. (a) Overview. The dynamometer run consists of two tests, a “cold” start test, after a minimum 12-hour and a maximum 36-hour soak according to the provisions of §§ 86.132 and 86.133, and a “hot” start test following the “cold” start by 10...

  4. Phase 1 Integrated Systems Test and Characterization Report for the 5-Megawatt Dynamometer and Controllable Grid Interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wallen, Robert B; Lambert, Scott R; Gevorgian, Vahan

    This report details the commissioning of the 5-megawatt dynamometer at the National Wind Technology Center at the National Renewable Energy Laboratory. The purpose of these characterization tests were to verify the dynamometer's performance over the widest possible range of operating conditions, gain insight into system-level behavior, and establish confidence in measurement data.

  5. Validity and reliability of a low-cost digital dynamometer for measuring isometric strength of lower limb.

    PubMed

    Romero-Franco, Natalia; Jiménez-Reyes, Pedro; Montaño-Munuera, Juan A

    2017-11-01

    Lower limb isometric strength is a key parameter to monitor the training process or recognise muscle weakness and injury risk. However, valid and reliable methods to evaluate it often require high-cost tools. The aim of this study was to analyse the concurrent validity and reliability of a low-cost digital dynamometer for measuring isometric strength in lower limb. Eleven physically active and healthy participants performed maximal isometric strength for: flexion and extension of ankle, flexion and extension of knee, flexion, extension, adduction, abduction, internal and external rotation of hip. Data obtained by the digital dynamometer were compared with the isokinetic dynamometer to examine its concurrent validity. Data obtained by the digital dynamometer from 2 different evaluators and 2 different sessions were compared to examine its inter-rater and intra-rater reliability. Intra-class correlation (ICC) for validity was excellent in every movement (ICC > 0.9). Intra and inter-tester reliability was excellent for all the movements assessed (ICC > 0.75). The low-cost digital dynamometer demonstrated strong concurrent validity and excellent intra and inter-tester reliability for assessing isometric strength in the main lower limb movements.

  6. Intramuscular Pressure Measurement During Locomotion in Humans

    NASA Technical Reports Server (NTRS)

    Ballard, Ricard E.

    1996-01-01

    To assess the usefulness of intramuscular pressure (IMP) measurement for studying muscle function during gait, IMP was recorded in the soleus and tibialis anterior muscles of ten volunteers during, treadmill walking, and running using transducer-tipped catheters. Soleus IMP exhibited single peaks during late-stance phase of walking (181 +/- 69 mmHg, mean +/- S.E.) and running (269 +/- 95 mmHg). Tibialis anterior IMP showed a biphasic response, with the largest peak (90 +/- 15 mmHg during walking and 151 +/- 25 mmHg during running) occurring shortly after heel strike. IMP magnitude increased with gait speed in both muscles. Linear regression of soleus IMP against ankle joint torque obtained by a dynamometer in two subjects produced linear relationships (r = 0.97). Application of these relationships to IMP data yielded estimated peak soleus moment contributions of 0.95-165 Nm/Kg during walking, and 1.43-2.70 Nm/Kg during running. IMP results from local muscle tissue deformations caused by muscle force development and thus, provides a direct, practical index of muscle function during locomotion in humans.

  7. The convertible engine: A dual-mode propulsion system

    NASA Technical Reports Server (NTRS)

    Mcardle, Jack G.

    1988-01-01

    A variable inlet guide vane (VIGV) convertible engine that could be used to power future high-speed rotorcraft was tested on an outdoor stand. The engine ran stably and smoothly in the turbofan, turboshaft, and dual (combined fan and shaft) power modes. In the turbofan mode with the VIGV open, fuel consumption was comparable to that of a conventional turbofan engine. In the turboshaft mode with the VIGV closed, fuel consumption was higher than that of present turboshaft engines because power was wasted in churning fan-tip air flow. In dynamic performance tests with a specially built digital engine control and using a waterbrake dynamometer for shaft load, the engine responded effectively to large steps in thrust command and shaft torque. Previous mission analyses of a conceptual X-wing rotorcraft capable of 400-knot cruise speed were revised to account for more fan-tip churning power loss that was originally estimated. The calculations confirm that using convertible engines rather than separate life and cruise engines would result in a smaller, lighter craft with lower fuel use and direct operating cost.

  8. Outdoor test stand performance of a convertible engine with variable inlet guide vanes for advanced rotorcraft propulsion

    NASA Technical Reports Server (NTRS)

    Mcardle, Jack G.

    1986-01-01

    A variable inlet guide van (VIGV) type convertible engine that could be used to power future high-speed rotorcraft was tested on an outdoor stand. The engine ran stably and smoothly in the turbofan, turboshaft, and dual (combined fan and shaft) power modes. In the turbofan mode with the VIGV open fuel consumption was comparable to that of a conventional turbofan engine. In the turboshaft mode with the VIGV closed fuel consumption was higher than that of present turboshaft engines because power was wasted in churning fan-tip airflow. In dynamic performance tests with a specially built digital engine control and using a waterbrake dynamometer for shaft load, the engine responded effectively to large steps in thrust command and shaft torque. Previous mission analyses of a conceptual X-wing rotorcraft capable of 400-knot cruise speed were revised to account for more fan-tip churning power loss than was originally estimated. The new calculations confirm that using convertible engines rather than separate lift and cruise engines would result in a smaller, lighter craft with lower fuel use and direct operating cost.

  9. Effect of Wiihabilitation on strength ratio of ankle muscles in adults

    PubMed Central

    Khalil, Aya A.; Mohamed, Ghada A.; El Rahman, Soheir M. Abd; Elhafez, Salam M.; Nassif, Nagui S.

    2016-01-01

    [Purpose] This study was conducted to investigate the effect of Wiihabilitation on the ankle dorsiflexion/plantar flexion strength ratio in adults. [Subjects and Methods] Thirty-two healthy male volunteers were randomly assigned to two equal groups (experimental and control). Participants in the experimental group received a Wiihabilitation training program for six weeks. Data were collected using a Biodex system 3 Isokinetic dynamometer. Peak torques of the dorsiflexors and plantar flexors were measured at an angular velocity of 60°/sec which in turn were used to derive the ankle dorsiflexion/plantar flexion strength ratio. [Results] The mean values of the ankle dorsiflexion/plantar flexion strength ratio decreased significantly between before and after the training in the experimental group, meanwhile there was no significant difference between before and after the training period in the control group . [Conclusion] Wiihabilitation has an impact on the ankle dorsiflexion/plantar flexion strength ratio, so it can be considered an effective training tool in terms of the ankle strength ratio. Thus, it could be recommended for both prevention and rehabilitation of ankle instability patients. PMID:27821951

  10. Leg intramuscular pressures during locomotion in humans

    NASA Technical Reports Server (NTRS)

    Ballard, R. E.; Watenpaugh, D. E.; Breit, G. A.; Murthy, G.; Holley, D. C.; Hargens, A. R.

    1998-01-01

    To assess the usefulness of intramuscular pressure (IMP) measurement for studying muscle function during gait, IMP was recorded in the soleus and tibialis anterior muscles of 10 volunteers during treadmill walking and running by using transducer-tipped catheters. Soleus IMP exhibited single peaks during late-stance phase of walking [181 +/- 69 (SE) mmHg] and running (269 +/- 95 mmHg). Tibialis anterior IMP showed a biphasic response, with the largest peak (90 +/- 15 mmHg during walking and 151 +/- 25 mmHg during running) occurring shortly after heel strike. IMP magnitude increased with gait speed in both muscles. Linear regression of soleus IMP against ankle joint torque obtained by a dynamometer produced linear relationships (n = 2, r = 0.97 for both). Application of these relationships to IMP data yielded estimated peak soleus moment contributions of 0.95-1.65 N . m/kg during walking, and 1.43-2.70 N . m/kg during running. Phasic elevations of IMP during exercise are probably generated by local muscle tissue deformations due to muscle force development. Thus profiles of IMP provide a direct, reproducible index of muscle function during locomotion in humans.

  11. Modelling and Prediction of Spark-ignition Engine Power Performance Using Incremental Least Squares Support Vector Machines

    NASA Astrophysics Data System (ADS)

    Wong, Pak-kin; Vong, Chi-man; Wong, Hang-cheong; Li, Ke

    2010-05-01

    Modern automotive spark-ignition (SI) power performance usually refers to output power and torque, and they are significantly affected by the setup of control parameters in the engine management system (EMS). EMS calibration is done empirically through tests on the dynamometer (dyno) because no exact mathematical engine model is yet available. With an emerging nonlinear function estimation technique of Least squares support vector machines (LS-SVM), the approximate power performance model of a SI engine can be determined by training the sample data acquired from the dyno. A novel incremental algorithm based on typical LS-SVM is also proposed in this paper, so the power performance models built from the incremental LS-SVM can be updated whenever new training data arrives. With updating the models, the model accuracies can be continuously increased. The predicted results using the estimated models from the incremental LS-SVM are good agreement with the actual test results and with the almost same average accuracy of retraining the models from scratch, but the incremental algorithm can significantly shorten the model construction time when new training data arrives.

  12. Improved transistorized AC motor controller for battery powered urban electric passenger vehicles

    NASA Technical Reports Server (NTRS)

    Peak, S. C.

    1982-01-01

    An ac motor controller for an induction motor electric vehicle drive system was designed, fabricated, tested, evaluated, and cost analyzed. A vehicle performance analysis was done to establish the vehicle tractive effort-speed requirements. These requirements were then converted into a set of ac motor and ac controller requirements. The power inverter is a three-phase bridge using power Darlington transistors. The induction motor was optimized for use with an inverter power source. The drive system has a constant torque output to base motor speed and a constant horsepower output to maximum speed. A gear shifting transmission is not required. The ac controller was scaled from the base 20 hp (41 hp peak) at 108 volts dec to an expanded horsepower and battery voltage range. Motor reversal was accomplished by electronic reversal of the inverter phase sequence. The ac controller can also be used as a boost chopper battery charger. The drive system was tested on a dynamometer and results are presented. The current-controlled pulse width modulation control scheme yielded improved motor current waveforms. The ac controller favors a higher system voltage.

  13. Effect of first and second generation biodiesel blends on engine performance and emission

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Azad, A. K., E-mail: azad.cqu@gmail.com, E-mail: a.k.azad@cqu.edu.au; Rasul, M. G., E-mail: m.rasul@cqu.edu.au; Bhuiya, M. M. K., E-mail: m.bhuiya@cqu.edu.au

    The biodiesel is a potential source of alternative fuel which can be used at different proportions with diesel fuel. This study experimentally investigated the effect of blend percentage on diesel engine performance and emission using first generation (soybean) and second generation (waste cooking) biodiesel. The characterization of the biodiesel was done according to ASTM and EN standards and compared with ultralow sulfur diesel (ULSD) fuel. A multi-cylinder test bed engine coupled with electromagnetic dynamometer and 5 gas analyzer were used for engine performance and emission test. The investigation was made using B5, B10 and B15 blends for both biodiesels. Themore » study found that brake power (BP) and brake torque (BT) slightly decreases and brake specific fuel consumption (BSFC) slightly increases with an increase in biodiesel blends ratio. Besides, a significant reduction in exhaust emissions (except NO{sub x} emission) was found for both biodiesels compared to ULSD. Soybean biodiesel showed better engine performance and emissions reduction compared with waste cooking biodiesel. However, NO{sub x} emission for B5 waste cooking biodiesel was lower than soybean biodiesel.« less

  14. Effect of Wiihabilitation on strength ratio of ankle muscles in adults.

    PubMed

    Khalil, Aya A; Mohamed, Ghada A; El Rahman, Soheir M Abd; Elhafez, Salam M; Nassif, Nagui S

    2016-10-01

    [Purpose] This study was conducted to investigate the effect of Wiihabilitation on the ankle dorsiflexion/plantar flexion strength ratio in adults. [Subjects and Methods] Thirty-two healthy male volunteers were randomly assigned to two equal groups (experimental and control). Participants in the experimental group received a Wiihabilitation training program for six weeks. Data were collected using a Biodex system 3 Isokinetic dynamometer. Peak torques of the dorsiflexors and plantar flexors were measured at an angular velocity of 60°/sec which in turn were used to derive the ankle dorsiflexion/plantar flexion strength ratio. [Results] The mean values of the ankle dorsiflexion/plantar flexion strength ratio decreased significantly between before and after the training in the experimental group, meanwhile there was no significant difference between before and after the training period in the control group . [Conclusion] Wiihabilitation has an impact on the ankle dorsiflexion/plantar flexion strength ratio, so it can be considered an effective training tool in terms of the ankle strength ratio. Thus, it could be recommended for both prevention and rehabilitation of ankle instability patients.

  15. Comparisons in the Recovery Response From Resistance Exercise Between Young and Middle-Aged Men.

    PubMed

    Gordon, Joseph A; Hoffman, Jay R; Arroyo, Eliott; Varanoske, Alyssa N; Coker, Nicholas A; Gepner, Yftach; Wells, Adam J; Stout, Jeffrey R; Fukuda, David H

    2017-12-01

    Gordon, JA III, Hoffman, JR, Arroyo, E, Varanoske, AN, Coker, NA, Gepner, Y, Wells, AJ, Stout, JR, and Fukuda, DH. Comparisons in the recovery response from resistance exercise between young and middle-aged men. J Strength Cond Res 31(12): 3454-3462, 2017-The purpose of this study was to compare the effects of a bout of high-volume isokinetic resistance exercise protocol (HVP) on lower-body strength and markers of inflammation and muscle damage during recovery between young and middle-aged adult men. Nineteen recreationally trained men were classified as either a young adult (YA: 21.8 ± 2.0 years; 90.7 ± 11.6 kg) or a middle-aged adult (MA: 47.0 ± 4.4 years; 96.0 ± 21.5 kg) group. The HVP consisted of 8 sets of 10 repetitions, with 1 minute of rest between each set, performed on an isokinetic dynamometer at 60°·s. Maximal voluntary isometric contractions and isokinetic peak torque (PKT) and average torque (AVGT) (measured at 240° and 60°·s, respectively) were assessed at baseline (BL), immediately post (IP), 120 minutes, 24, and 48 hours after HVP. Blood was obtained at BL, IP, 30, 60, 120 minute, 24, and 48 hours after HVP to assess muscle damage and inflammation. All performance data were analyzed using repeated measures analysis of covariance, whereas all inflammatory and muscle damage markers were analyzed using a 2-way (time × group) repeated measures analysis of variance. Results revealed no between-group differences for PKT, AVGT, or rate of torque development at 200 ms (RTD200). No between-group differences in myoglobin, creatine kinase, C-reactive protein, or interleukin-6 were observed. Although BL differences in muscle performance were observed between YA and MA, no between-group differences were noted in performance recovery measures from high-volume isokinetic exercise in recreationally trained men. These results also indicate that the inflammatory and muscle damage response from high-volume isokinetic exercise is similar between recreationally trained, young, and middle-aged adult men.

  16. Normative Quadriceps and Hamstring Muscle Strength Values for Female, Healthy, Elite Handball and Football Players.

    PubMed

    Risberg, May A; Steffen, Kathrin; Nilstad, Agnethe; Myklebust, Grethe; Kristianslund, Eirik; Moltubakk, Marie M; Krosshaug, Tron

    2018-05-23

    Risberg, MA, Steffen, K, Nilstad, A, Myklebust, G, Kristianslund, E, Moltubakk, MM, and Krosshaug, T. Normative quadriceps and hamstring muscle strength values for female, healthy, elite handball and football players. J Strength Cond Res XX(X): 000-000, 2018-This study presents normative values for isokinetic knee extension and flexion muscle strength tests in 350 elite, female, handball (n = 150) and football (n = 200) players. Isokinetic concentric muscle strength tests at 60°·sec were recorded bilaterally using a dynamometer. Peak torque (in Newton meter [N·m]), body mass normalized peak torque (N·m·kg), and hamstring to quadriceps ratio (H:Q ratio) for dominant and nondominant legs were recorded. The female elite players were 20.9 ± 4.0 years, started playing at the elite level at the age of 18.2 ± 2.7 years, with a mean of 9.7 ± 2.2 hours of weekly in-season training. Handball players demonstrated greater quadriceps muscle strength compared with football players (11.0%) (p < 0.001), also when normalized to body mass (4.1%) (p = 0.012), but not for weight-adjusted hamstring muscle strength. The H:Q ratio was higher on the dominant compared with the nondominant leg for handball players only (p = 0.012).The H:Q ratio was significantly lower for handball players (0.58) compared with football players (0.60) (p < 0.02). These normative values for isokinetic knee extension and flexion torques of healthy, elite, female handball and football players can be used to set rehabilitation goals for muscle strength after injury and enable comparison with uninjured legs. Significantly greater quadriceps muscle strength was found for handball players compared with football players, also when normalized to body mass.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

  17. Local mechanical response of cells to the controlled rotation of magnetic nanorods.

    PubMed

    Castillo, Matias; Ebensperger, Roberto; Wirtz, Denis; Walczak, Magdalena; Hurtado, Daniel E; Celedon, Alfredo

    2014-11-01

    The mechanical response of the cytoplasm was investigated by the intracellular implantation of magnetic nanorods and exposure to low-frequency rotatory magnetic fields. Nanorods (Pt-Ni, ∼200 nm diameter) fabricated by electrodeposition in templates of porous alumina with lengths of approximately 2 and 5 µm were inserted into NIH/3T3 fibroblasts and manipulated with a rotational magnetic field. Nanorod rotation was observed only for torques greater than 3.0 × 10(-16) Nm, suggesting a Bingham-type behavior of the cytoplasm. Higher torques produced considerable deformation of the intracellular material. The cell nucleus and cell membrane were significantly deformed by nanorods actuated by 4.5 × 10(-15) Nm torques. Our results demonstrate that nanorods under magnetic fields are an effective tool to mechanically probe the intracellular environment. We envision that our findings may contribute to the noninvasive and direct mechanical characterization of the cytoplasm. © 2014 Wiley Periodicals, Inc.

  18. Local mechanical response of cells to the controlled rotation of magnetic nanorods

    PubMed Central

    Castillo, Matias; Ebensperger, Roberto; Wirtz, Denis; Walczak, Magdalena; Hurtado, Daniel E.; Celedon, Alfredo

    2015-01-01

    The mechanical response of the cytoplasm was investigated by the intracellular implantation of magnetic nanorods and exposure to low-frequency rotatory magnetic fields. Nanorods (Pt-Ni, ~200 nm diameter) fabricated by electrodeposition in templates of porous alumina with lengths of approximately 2 and 5 μm were inserted into NIH/ 3T3 fibroblasts and manipulated with a rotational magnetic field. Nanorod rotation was observed only for torques greater than 3.0 × 10−16 Nm, suggesting a Bingham-type behavior of the cytoplasm. Higher torques produced considerable deformation of the intracellular material. The cell nucleus and cell membrane were significantly deformed by nanorods actuated by 4.5 × 10−15 Nm torques. Our results demonstrate that nanorods under magnetic fields are an effective tool to mechanically probe the intracellular environment. We envision that our findings may contribute to the noninvasive and direct mechanical characterization of the cytoplasm. PMID:24700696

  19. Materials-Enabled High-Efficiency (MEHE) Heavy-Duty Diesel Engines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kass, M.; Veliz, M.

    2011-09-30

    The purpose of this Cooperative Research and Development Agreement (CRADA) between UTBattelle, Inc. and Caterpillar, Inc. was to improve diesel engine efficiency by incorporating advanced materials to enable higher combustion pressures and temperatures necessary for improved combustion. The project scope also included novel materials for use in advanced components and designs associated with waste-heat recovery and other concepts for improved thermal efficiency. Caterpillar initially provided ORNL with a 2004 Tier 2 C15 ACERT diesel engine (designed for on-highway use) and two 600 hp motoring dynamometers. The first year of the CRADA effort was focused on establishing a heavy-duty experimental enginemore » research cell. First year activities included procuring, installing and commissioning the cell infrastructure. Infrastructure components consisted of intake air handling system, water tower, exhaust handling system, and cell air conditioning. Other necessary infrastructure items included the fuel delivery system and bottled gas handling to support the analytical instrumentation. The second year of the CRADA focused on commissioning the dynamometer system to enable engine experimentation. In addition to the requirements associated with the dynamometer controller, the electrical system needed a power factor correction system to maintain continuity with the electrical grid. During the second year the engine was instrumented and baseline operated to confirm performance and commission the dynamometer. The engine performance was mapped and modeled according to requirements provided by Caterpillar. This activity was further supported by a Work-for-Others project from Caterpillar to evaluate a proprietary modeling system. A second Work-for-Others activity was performed to evaluate a novel turbocharger design. This project was highly successful and may lead to new turbocharger designs for Caterpillar heavy-duty diesel engines. During the third (and final) year of the CRADA, a novel valve material was evaluated to assess high temperature performance and durability. A series of prototype valves, composed of a unique nickel-alloy was placed in the engine head. The engine was aggressively operated using a transient test cycle for 200 hours. The valve recession was periodically measured to determine valve performance. Upon completion of the test the valves were removed and returned to Caterpillar for additional assessment. Industrial in-kind support was available throughout the project period. Review of the status and research results were carried out on a regular basis (meetings and telecons) which included direction for future work activities. A significant portion of the industrial support was in the form of information exchange and technical consultation.« less

  20. Comparison between overground and dynamometer manual wheelchair propulsion.

    PubMed

    Koontz, Alicia M; Worobey, Lynn A; Rice, Ian M; Collinger, Jennifer L; Boninger, Michael L

    2012-08-01

    Laboratory-based simulators afford many advantages for studying physiology and biomechanics; however, they may not perfectly mimic wheelchair propulsion over natural surfaces. The goal of this study was to compare kinetic and temporal parameters between propulsion overground on a tile surface and on a dynamometer. Twenty-four experienced manual wheelchair users propelled at a self-selected speed on smooth, level tile and a dynamometer while kinetic data were collected using an instrumented wheel. A Pearson correlation test was used to examine the relationship between propulsion variables obtained on the dynamometer and the overground condition. Ensemble resultant force and moment curves were compared using cross-correlation and qualitative analysis of curve shape. User biomechanics were correlated (R ranging from 0.41 to 0.83) between surfaces. Overall, findings suggest that although the dynamometer does not perfectly emulate overground propulsion, wheelchair users were consistent with the direction and amount of force applied, the time peak force was reached, push angle, and their stroke frequency between conditions.

  1. Comparison Between Overground and Dynamometer Manual Wheelchair Propulsion

    PubMed Central

    Worobey, Lynn A.; Rice, Ian M.; Collinger, Jennifer L.; Boninger, Michael L.

    2017-01-01

    Laboratory-based simulators afford many advantages for studying physiology and biomechanics; however, they may not perfectly mimic wheelchair propulsion over natural surfaces. The goal of this study was to compare kinetic and temporal parameters between propulsion overground on a tile surface and on a dynamometer. Twenty-four experienced manual wheelchair users propelled at a self-selected speed on smooth, level tile and a dynamometer while kinetic data were collected using an instrumented wheel. A Pearson correlation test was used to examine the relationship between propulsion variables obtained on the dynamometer and the overground condition. Ensemble resultant force and moment curves were compared using cross-correlation and qualitative analysis of curve shape. User biomechanics were correlated (R ranging from 0.41 to 0.83) between surfaces. Overall, findings suggest that although the dynamometer does not perfectly emulate overground propulsion, wheelchair users were consistent with the direction and amount of force applied, the time peak force was reached, push angle, and their stroke frequency between conditions. PMID:22085811

  2. Influence of joint angular velocity on electrically evoked concentric force potentiation induced by stretch-shortening cycle in young adults.

    PubMed

    Fukutani, Atsuki; Kurihara, Toshiyuki; Isaka, Tadao

    2015-01-01

    During a stretch- shortening cycle (SSC), muscle force attained during concentric contractions (shortening phase) is potentiated by the preceding eccentric contractions (lengthening phase). The purpose of this study was to examine the influence of joint angular velocity on force potentiation induced by SSC (SSC effect). Twelve healthy men (age, 24.2 ± 3.2 years; height, 1.73 ± 0.05 m; body mass, 68.1 ± 11.0 kg) participated in this study. Ankle joint angle was passively moved by a dynamometer, with range of motion from dorsiflexion (DF) 15° to plantarflexion (PF) 15°. Muscle contractions were evoked by tetanic electrical stimulation. Joint angular velocity of concentric contraction was set at 30°/s and 150°/s. Magnitude of SSC effect was calculated as the ratio of joint torque obtained by concentric contraction with preliminary eccentric contraction trial relative to that obtained by concentric contraction without preliminary eccentric contraction trial. As a result, magnitude of SSC effect calculated at three joint angles was significantly larger in the 150°/s condition than in the 30°/s condition (p < 0.05). These results indicate that the magnitude of SSC effect is affected by joint angular velocity, which is larger when joint angular velocity is larger. This phenomenon would be caused by insufficient duration to increase activation level in the large joint angular velocity condition. When the duration to increase activation level is insufficient due to short contraction duration, preactivation (one of the factors of SSC effect) leads to a significant increase in joint torque.

  3. Sex-Related and Age-Related Differences in Knee Strength of Basketball Players Ages 11–17 Years

    PubMed Central

    Vardaxis, Vassilios G.

    2003-01-01

    Objective: To assess hamstrings and quadriceps strength of basketball players ages 11–13 and 15–17 years. Design and Setting: This cross-sectional study occurred during the 2000 American Youth Basketball Tour National Tournament. We investigated whether sex- or age-related strength differences existed among study participants. Subjects: Forty-one tournament participants (22 girls, 19 boys; 11–13 or 15–17 years old) who reported no history of knee sprain or surgery were recruited. Measurements: We used a Cybex II dynamometer to obtain isokinetic concentric peak torques relative to body mass (Nm/kg) at 60°/s for hamstrings and quadriceps bilaterally. From average peak torques, we determined ipsilateral hamstrings:quadriceps and homologous muscle-group ratios. Results: Correlations between hamstrings and quadriceps strength measures ranged from 0.78 to 0.97. Players 15–17 years old had greater relative hamstrings and quadriceps strength than 11- to 13-year-old athletes. Age and sex interacted significantly for quadriceps strength. The quadriceps strength of 15- to 17-year-old girls did not differ from that of 11- to 13-year-old girls, whereas 15- to 17-year-old boys had stronger quadriceps than 11- to 13-year-old boys. Boys 15–17 years old had greater quadriceps strength than girls 15–17 years old. Conclusions: This study is unique in providing normative data for the hamstrings and quadriceps strength of basketball players 11–13 and 15–17 years old. Age-related strength differences did not occur consistently between the sexes, as girls 11–13 and 15–17 years old had similar relative quadriceps strength. PMID:14608433

  4. A Novel Strategy to Eliminate the Influence of Water Adsorption on Quartz Surfaces on Piezoelectric Dynamometers

    PubMed Central

    Jia, Zhenyuan; Jin, Lei; Liu, Wei; Ren, Zongjin

    2016-01-01

    Piezoelectric dynamometers are out of use in high humidity. Experimental results showed that piezoelectric coefficients measured by the force-induced charges method initially fluctuated in a small range and then was unstable, and they could not be measured at high relative humidity (RH). The traditional shielding method-insulation paste was not quiet convenient, and it even added the weight of piezoelectric dynamometers. In this paper, a novel strategy that eliminates the influence of water adsorption with quartz surfaces on piezoelectric dynamometers was proposed. First, a water-quartz model was developed to analyze the origin of the RH effect. In the model, water vapor, which was adsorbed by the quartz sheet side surface, was considered. Second, equivalent sheet resistor of the side surface was researched, while the relationship of the three R’s (Roughness, RH, and Resistor) was respectively discussed based on the adsorption mechanism. Finally, fluorination technology was skillfully adapted to each surface of quartz sheets to shield the water vapor. The experiment verified the fluorination strategy and made piezoelectric dynamometers work in high humidity up to 90%RH successfully. The results showed that the presented model above was reasonable. In addition, these observations also drew some useful insights to change the structure of piezoelectric dynamometers and improve the properties. PMID:27399719

  5. Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors.

    PubMed

    Ruschel, Caroline; Haupenthal, Alessandro; Jacomel, Gabriel Fernandes; Fontana, Heiliane de Brito; Santos, Daniela Pacheco dos; Scoz, Robson Dias; Roesler, Helio

    2015-05-20

    Isometric muscle strength of knee extensors has been assessed for estimating performance, evaluating progress during physical training, and investigating the relationship between isometric and dynamic/functional performance. To assess the validity and reliability of an adapted leg-extension machine for measuring isometric knee extensor force. Validity (concurrent approach) and reliability (test and test-retest approach) study. University laboratory. 70 healthy men and women aged between 20 and 30 y (39 in the validity study and 31 in the reliability study). Intraclass correlation coefficient (ICC) values calculated for the maximum voluntary isometric torque of knee extensors at 30°, 60°, and 90°, measured with the prototype and with an isokinetic dynamometer (ICC2,1, validity study) and measured with the prototype in test and retest sessions, scheduled from 48 h to 72 h apart (ICC1,1, reliability study). In the validity analysis, the prototype showed good agreement for measurements at 30° (ICC2,1 = .75, SEM = 18.2 Nm) and excellent agreement for measurements at 60° (ICC2,1 = .93, SEM = 9.6 Nm) and at 90° (ICC2,1 = .94, SEM = 8.9 Nm). Regarding the reliability analysis, between-days' ICC1,1 were good to excellent, ranging from .88 to .93. Standard error of measurement and minimal detectable difference based on test-retest ranged from 11.7 Nm to 18.1 Nm and 32.5 Nm to 50.1 Nm, respectively, for the 3 analyzed knee angles. The analysis of validity and repeatability of the prototype for measuring isometric muscle strength has shown to be good or excellent, depending on the knee joint angle analyzed. The new instrument, which presents a relative low cost and easiness of transportation when compared with an isokinetic dynamometer, is valid and provides consistent data concerning isometric strength of knee extensors and, for this reason, can be used for practical, clinical, and research purposes.

  6. Mechanical effects of third-order movement in self-ligated brackets by the measurement of torque expression.

    PubMed

    Major, Thomas W; Carey, Jason P; Nobes, David S; Heo, Giseon; Major, Paul W

    2011-01-01

    Axial rotation of orthodontic wire produces buccal or lingual root movement and is often referred to as third-order movement or "torque expression." The objective of this study was to quantify torque expression in 3 self-ligation bracket systems (Damon Q, Ormco, Orange, Calif; In-Ovation R, GAC, Bohemia, NY; and Speed, Strite Industries, Cambridge, Ontario, Canada) during loading and unloading. A stepper motor was used to rotate a wire in a fixed bracket slot from -15° to 63° in 3° increments, and then back to -15°. The bracket was mounted on top of a load cell that measured forces and moments in all directions. Damon's and In-Ovation's maximum average torque values at 63° were 105 and 113 Nmm, respectively. Many Speed brackets experienced premature loss of torque between 48° and 63°, and the average maximum was 82 Nmm at 54°. The torque plays for Damon, In-Ovation, and Speed were 11.3°, 11.9°, and 10.8°, respectively. Generally, In-Ovation expressed the most torque at a given angle of twist, followed by Damon and then Speed. However, there was no significant difference between brackets below 34 Nmm of torque. From a clinical perspective, the torque plays between brackets were virtually indistinguishable. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  7. Silent Flange Coupling Design Used for the Schenck Eddy Current Dynamometer

    NASA Astrophysics Data System (ADS)

    Schinteie, D.; Croitorescu, V.

    2016-11-01

    The silent flange used for coupling different machines/systems to an eddy current dynamometer represents one of the modular components each test-bench should use. By introducing a silent flange into a dynamometer, the coupling steps are easier and faster. For an appropriate design, the silent flange was analyzed using dedicated software during different operation procedures and scenarios, for materials that allow easy manufacturing. This study shows that the design for this silent flange model has no danger of failure due to the small deformation and the values for the equivalent stresses. The silent flange coupling is suitable for the dynamometer for his high positioning accuracy, the zero backlash and the fact that there is no motion between the shafts.

  8. Axial calibration methods of piezoelectric load sharing dynamometer

    NASA Astrophysics Data System (ADS)

    Zhang, Jun; Chang, Qingbing; Ren, Zongjin; Shao, Jun; Wang, Xinlei; Tian, Yu

    2018-06-01

    The relationship between input and output of load sharing dynamometer is seriously non-linear in different loading points of a plane, so it's significant for accutately measuring force to precisely calibrate the non-linear relationship. In this paper, firstly, based on piezoelectric load sharing dynamometer, calibration experiments of different loading points are performed in a plane. And then load sharing testing system is respectively calibrated based on BP algorithm and ELM (Extreme Learning Machine) algorithm. Finally, the results show that the calibration result of ELM is better than BP for calibrating the non-linear relationship between input and output of loading sharing dynamometer in the different loading points of a plane, which verifies that ELM algorithm is feasible in solving force non-linear measurement problem.

  9. Astronaut candidate strength measurement using the Cybex 2 and the LIDO Multi-Joint 2 dynamometers

    NASA Technical Reports Server (NTRS)

    Carroll, Amy E.; Wilmington, Robert P.

    1992-01-01

    The Anthropometry and Biomechanics Laboratory in the man-Systems division at NASA's Johnson Space Center has as one of its responsibilities the anthropometry and strength measurement data collection of astronaut candidates. The anthropometry data is used to ensure that the astronaut candidates are within the height restrictions for space vehicle and space suit design requirements, for example. The strength data is used to help detect abnormalities or isolate injuries to muscle groups that could jeopardize the astronauts safety. The Cybex II Dynamometer has been used for strength measurements from 1985 through 1991. The Cybex II was one of the first instruments of its kind to measure strength and similarity of muscle groups by isolating the specific joint of interest. In November 1991, a LIDO Multi-Joint II Dynamometer was purchased to upgrade the strength measurement data collection capability of the Anthropometry and Biomechanics Laboratory. The LIDO Multi-Joint II Dynamometer design offers several advantages over the Cybex II Dynamometer including a more sophisticated method of joint isolation and a more accurate and efficient computer based data collection system.

  10. A microcomputer controlled snow ski binding system--I. Instrumentation and field evaluation.

    PubMed

    MacGregor, D; Hull, M L; Dorius, L K

    1985-01-01

    This paper presents the design and field evaluation of the first microcomputer controlled ski binding system. This system incorporates an Intel 8086 microcomputer controller and an integral binding/dynamometer. This instrumentation system not only undertakes real time control, but also it records dynamometer data via a miniature digital cassette tape recorder. The integral binding/dynamometer offers the same operational and mounting convenience of commercially available mechanical bindings. The binding may be released either manually or electrically via the controller. Comprised of four octagonal half strain rings, the strain gage dynamometer measures the three moment load components at the boot. To enable the user to conveniently operate the computer, extensive operating software was developed. The operating software is discussed in relation to both the acquisition and storage of data from the dynamometer and the control of the electro-mechanical snow ski binding. The binding system has been used successfully to both record boot moment components and control ski binding release during actual skiing maneuvers. Moment histories typical of three common recreational skiing maneuvers are presented.

  11. 40 CFR 86.131-00 - Vehicle preparation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... test dynamometer. This signal provides the input information that controls dynamometer dynamic inertia... implement dynamic inertia adjustments for a portion or all of their product line, this requirement is not...

  12. Frictional Torque Reduction in Taylor-Couette Flows with Riblet-Textured Rotors

    NASA Astrophysics Data System (ADS)

    Raayai, Shabnam; McKinley, Gareth

    2017-11-01

    Inspired by the riblets on the denticles of fast swimming shark species, periodic surface microtextures of different shapes have been studied under laminar and turbulent flow conditions to understand their drag reduction mechanism and to offer guides for designing optimized low-friction bio-inspired surfaces. Various reports over the past four decades have suggested that riblet surfaces can reduce the frictional drag force in high Reynolds number laminar and turbulent flow regimes. Here, we investigate the effect of streamwise riblets on torque reduction in steady flow between concentric cylinders, known as Taylor-Couette Flow. Using 3D printed riblet-textured rotors and a custom-built Taylor-Couette cell which can be mounted on a rheometer we measure the torque on the inner rotor as a function of three different dimensionless parameters; the Reynolds number of the flow, the sharpness of the riblets, and the size of the riblets with respect to the scale of the Taylor-Couette cell. Our experimental results in the laminar viscous flow regime show a reduction in torque up to 10% over a wide range of Reynolds numbers, that is a non-monotonic function of the aspect ratio and independent of Re. However, after transition to the Taylor vortex regime, the modification in torque becomes a function of the Reynolds number, while remaining a non-monotonic function of the aspect ratio. Using finite volume modelling of the geometry we discuss the changes in the Taylor-Couette flow in presence of the riblets compared to the case of smooth rotors and the resulting torque reduction as a function of the parameter space defined above.

  13. 40 CFR 1066.410 - Dynamometer test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... configuration that allows for proper simulation of vehicle cooling during in-use operation, subject to our... simulation of the actual normal forces that the tire and dynamometer roll interface would see if a loaded...

  14. 40 CFR 1066.410 - Dynamometer test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... configuration that allows for proper simulation of vehicle cooling during in-use operation, subject to our... simulation of the actual normal forces that the tire and dynamometer roll interface would see if a loaded...

  15. National Wind Technology Center Dynamic 5-Megawatt Dynamometer

    ScienceCinema

    Felker, Fort

    2018-06-06

    The National Wind Technology Center (NWTC) offers wind industry engineers a unique opportunity to conduct a wide range of tests. Its custom-designed dynamometers can test wind turbine systems from 1 kilowatt (kW) to 5 megawatts (MW). The NWTC's new dynamometer facility simulates operating field conditions to assess the reliability and performance of wind turbine prototypes and commercial machines, thereby reducing deployment time, failures, and maintenance or replacement costs. Funded by the U.S. Department of Energy with American Recovery and Reinvestment Act (ARRA) funds, the 5-MW dynamometer will provide the ability to test wind turbine drivetrains and connect those drivetrains directly to the electricity grid or through a controllable grid interface (CGI). The CGI tests the low-voltage ride-through capability of a drivetrain as well as its response to faults and other abnormal grid conditions.

  16. Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt.

    PubMed

    Aramaki, Hidefumi; Katoh, Munenori; Hiiragi, Yukinobu; Kawasaki, Tsubasa; Kurihara, Tomohisa; Ohmi, Yorikatsu

    2016-07-01

    [Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subjects' right legs was measured under two posture positions using two devices: a handheld dynamometer with a belt and an isokinetic dynamometer. Reliability was evaluated using an intra-class correlation coefficient (ICC); relatedness and validity were evaluated using Pearson's product moment correlation coefficient. Differences in measurements of devices were assessed by two-way ANOVA. [Results] ICC (1, 1) was ≥0.9; significant positive correlations in measurements were found between the two devices under both conditions. No main effect was found between the measurement values. [Conclusion] Our findings revealed that there was relatedness, reliability, and validity of this method for isometric muscle strength measurements using a handheld dynamometer with a belt.

  17. Voltage-controlled magnetization switching in MRAMs in conjunction with spin-transfer torque and applied magnetic field

    NASA Astrophysics Data System (ADS)

    Munira, Kamaram; Pandey, Sumeet C.; Kula, Witold; Sandhu, Gurtej S.

    2016-11-01

    Voltage-controlled magnetic anisotropy (VCMA) effect has attracted a significant amount of attention in recent years because of its low cell power consumption during the anisotropy modulation of a thin ferromagnetic film. However, the applied voltage or electric field alone is not enough to completely and reliably reverse the magnetization of the free layer of a magnetic random access memory (MRAM) cell from anti-parallel to parallel configuration or vice versa. An additional symmetry-breaking mechanism needs to be employed to ensure the deterministic writing process. Combinations of voltage-controlled magnetic anisotropy together with spin-transfer torque (STT) and with an applied magnetic field (Happ) were evaluated for switching reliability, time taken to switch with low error rate, and energy consumption during the switching process. In order to get a low write error rate in the MRAM cell with VCMA switching mechanism, a spin-transfer torque current or an applied magnetic field comparable to the critical current and field of the free layer is necessary. In the hybrid processes, the VCMA effect lowers the duration during which the higher power hungry secondary mechanism is in place. Therefore, the total energy consumed during the hybrid writing processes, VCMA + STT or VCMA + Happ, is less than the energy consumed during pure spin-transfer torque or applied magnetic field switching.

  18. The effect of different torque wrenches on rotational stiffness in compressive femoral nails: a biomechanical study.

    PubMed

    Karaarslan, A A; Acar, N

    2018-02-01

    Rotation instability and locking screws failure are common problems. We aimed to determine optimal torque wrench offering maximum rotational stiffness without locking screw failure. We used 10 conventional compression nails, 10 novel compression nails and 10 interlocking nails with 30 composite femurs. We examined rotation stiffness and fracture site compression value by load cell with 3, 6 and 8 Nm torque wrenches using torsion apparatus with a maximum torque moment of 5 Nm in both directions. Rotational stiffness of composite femur-nail constructs was calculated. Rotational stiffness of composite femur-compression nail constructs compressed by 6 Nm torque wrench was 3.27 ± 1.81 Nm/angle (fracture site compression: 1588 N) and 60% more than that compressed with 3 Nm torque wrench (advised previously) with 2.04 ± 0.81 Nm/angle (inter fragmentary compression: 818 N) (P = 0.000). Rotational stiffness of composite-femur-compression nail constructs compressed by 3 Nm torque wrench was 2.04 ± 0.81 Nm/angle (fracture site compression: 818 N) and 277% more than that of interlocking nail with 0.54 ± 0.08 Nm/angle (fracture site compression: 0 N) (P = 0.000). Rotational stiffness and fracture site compression value produced by 3 Nm torque wrench was not satisfactory. To obtain maximum rotational stiffness and fracture site compression value without locking screw failure, 6 Nm torque wrench in compression nails and 8 Nm torque wrench in novel compression nails should be used.

  19. Spin-transfer-torque efficiency enhanced by edge-damage of perpendicular magnetic random access memories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Kyungmi; Lee, Kyung-Jin, E-mail: kj-lee@korea.ac.kr; Department of Materials Science and Engineering, Korea University, Seoul 136-713

    2015-08-07

    We numerically investigate the effect of magnetic and electrical damages at the edge of a perpendicular magnetic random access memory (MRAM) cell on the spin-transfer-torque (STT) efficiency that is defined by the ratio of thermal stability factor to switching current. We find that the switching mode of an edge-damaged cell is different from that of an undamaged cell, which results in a sizable reduction in the switching current. Together with a marginal reduction of the thermal stability factor of an edge-damaged cell, this feature makes the STT efficiency large. Our results suggest that a precise edge control is viable formore » the optimization of STT-MRAM.« less

  20. 40 CFR 92.106 - Equipment for loading the engine.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... settings except idle and dynamic brake; and (ii) Less accuracy and precision is allowed at idle and dynamic...) For engine testing using a dynamometer, the engine dynamometer system must be capable of controlling...

  1. The development of peripheral fatigue and short-term recovery during self-paced high-intensity exercise

    PubMed Central

    Froyd, Christian; Millet, Guillaume Y; Noakes, Timothy D

    2013-01-01

    The time course of muscular fatigue that develops during and after an intense bout of self-paced dynamic exercise was characterized by using different forms of electrical stimulation (ES) of the exercising muscles. Ten active subjects performed a time trial (TT) involving repetitive concentric extension/flexion of the right knee using a Biodex dynamometer. Neuromuscular function (NMF), including ES and a 5 s maximal isometric voluntary contraction (MVC), was assessed before the start of the TT and immediately (<5 s) after each 20% of the TT had been completed, as well as 1, 2, 4 and 8 min after TT termination. The TT time was 347 ± 98 s. MVCs were 52% of baseline values at TT termination. Torque responses from ES were reduced to 33–68% of baseline using different methods of stimulation, suggesting that the extent to which peripheral fatigue is documented during exercise depends upon NMF assessment methodology. The major changes in muscle function occurred within the first 40% of exercise. Significant recovery in skeletal muscle function occurs within the first 1–2 min after exercise, showing that previous studies may have underestimated the extent to which peripheral fatigue develops during exercise. PMID:23230235

  2. Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Link, H.; Keller, J.; Guo, Y.

    2013-04-01

    Gearboxes in wind turbines have not been achieving their expected design life even though they commonly meet or exceed the design criteria specified in current design standards. One of the basic premises of the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) is that the low gearbox reliability results from the absence of critical elements in the design process or insufficient design tools. Key goals of the GRC are to improve design approaches and analysis tools and to recommend practices and test methods resulting in improved design standards for wind turbine gearboxes that lower the cost of energy (COE)more » through improved reliability. The GRC uses a combined gearbox testing, modeling and analysis approach, along with a database of information from gearbox failures collected from overhauls and investigation of gearbox condition monitoring techniques to improve wind turbine operations and maintenance practices. Testing of Gearbox 2 (GB2) using the two-speed turbine controller that has been used in prior testing. This test series will investigate non-torque loads, high-speed shaft misalignment, and reproduction of field conditions in the dynamometer. This test series will also include vibration testing using an eddy-current brake on the gearbox's high speed shaft.« less

  3. Vehicle Integrated Photovoltaics for Compression Ignition Vehicles: An Experimental Investigation of Solar Alkaline Water Electrolysis for Improving Diesel Combustion and a Solar Charging System for Reducing Auxiliary Engine Loads

    NASA Astrophysics Data System (ADS)

    Negroni, Garry Inocentes

    Vehicle-integrated photovoltaic electricity can be applied towards aspiration of hydrogen-oxygen-steam gas produced through alkaline electrolysis and reductions in auxiliary alternator load for reducing hydrocarbon emissions in low nitrogen oxide indirect-injection compression-ignition engines. Aspiration of 0.516 ± 0.007 liters-per-minute of gas produced through alkaline electrolysis of potassium-hydroxide 2wt.% improves full-load performance; however, part-load performance decreases due to auto-ignition of aspirated gas prior to top-dead center. Alternator load reductions offer improved part-load and full-load performance with practical limitations resulting from accessory electrical loads. In an additive approach, solar electrolysis can electrochemically convert solar photovoltaic electricity into a gas comprised of stoichiometric hydrogen and oxygen gas. Aspiration of this hydrogen-oxygen gas enhances combustion properties decreasing emissions and increased combustion efficiency in light-duty diesel vehicles. The 316L stainless steel (SS) electrolyser plates are arranged with two anodes and three cathodes space with four bipolar plates delineating four stacks in parallel with five cells per stack. The electrolyser was tested using potassium hydroxide 2 wt.% and hydronium 3wt.% at measured voltage and current inputs. The flow rate output from the reservoir cell was measured in parallel with the V and I inputs producing a regression model correlating current input to flow rate. KOH 2 wt.% produced 0.005 LPM/W, while H9O44 3 wt.% produced less at 0.00126 LPM/W. In a subtractive approach, solar energy can be used to charge a larger energy storage device, as is with plug-in electric vehicles, in order to alleviate the engine of the mechanical load placed upon it by the vehicles electrical accessories through the alternator. Solar electrolysis can improve part-load emissions and full-load performance. The average solar-to-battery efficiency based on the OEM rated efficiency was 11.4%. The average voltage efficiency of the electrolyser during dynamometer testing was 69.16%, producing a solar-to-electrolysis efficiency of 7.88%. At varying engine speeds, HC emissions decreased an average of 54.4% at multiple engine speeds at part-load, while CO2 increased by 2.54% due to oxygen enrichment of intake air. However, the auto-ignition of a small amount of hydrogen (0.0035% of diesel fuel energy) had a negative impact on part-load power (-3.671%) and torque (-3.296%). Full-load sweep testing showed an increase in peak power (1.562%) and peak torque (2.608%). Solar electrolysis gas aspiration reduced soot opacity by 31.5%. The alternator-less part-load step tests show average HC and CO2 emissions decrease on average 25.05% and 1.14% respectively. The test also indicates an increase in average part-load power (1.57%) and torque (2.12%). Alternator-less operation can reduce soot opacity by 56.76%. Full-load testing of the vehicle with alternator unplugged indicates that alternator load upon an engine increase with engine ne speed even with no load and no pilot excitation. Alternator load elimination's performance and emissions improvements should be considered, however, practical limitations exist in winter-night, summer-midday scenarios and for longer duration of operation.

  4. Constraints on models for the flagellar rotary motor.

    PubMed Central

    Berg, H C

    2000-01-01

    Most bacteria that swim are propelled by flagellar filaments, each driven at its base by a rotary motor embedded in the cell wall and cytoplasmic membrane. A motor is about 45 nm in diameter and made up of about 20 different kinds of parts. It is assembled from the inside out. It is powered by a proton (or in some species, a sodium-ion) flux. It steps at least 400 times per revolution. At low speeds and high torques, about 1000 protons are required per revolution, speed is proportional to protonmotive force, and torque varies little with temperature or hydrogen isotope. At high speeds and low torques, torque increases with temperature and is sensitive to hydrogen isotope. At room temperature, torque varies remarkably little with speed from about -100 Hz (the present limit of measurement) to about 200 Hz, and then it declines rapidly reaching zero at about 300 Hz. These are facts that motor models should explain. None of the existing models for the flagellar rotary motor completely do so. PMID:10836502

  5. Frequency analysis of tangential force measurements on a vertical axis wind turbine

    NASA Astrophysics Data System (ADS)

    Rossander, Morgan; Goude, Anders; Bernhoff, Hans; Eriksson, Sandra

    2016-09-01

    This paper presents experimental results of the torque ripple obtained from a three bladed 12 kW experimental H-rotor prototype. The measurements are performed by means of load cells installed on the base of the struts and by electrical measurements on the generator. The resulting torques are analysed in terms of frequency spectrum and order spectrum (synchronized with rotation). The measurements are compared to aerodynamic simulations of the turbine. The expected large torque ripple at three times the rotational speed (3 p) is only weakly represented at the hub and in the generator. This suggests that the system is filtering the ripple and/or that the simulations are overestimating the 3 p component. The torque ripple loads on the drive train are therefore lower than anticipated. Even if highly attenuated, most of the low frequencies correlating to aerodynamics are still represented in the generator electrical torque. Given a certain baseline, this opens for possible online monitoring of unbalances in the turbine by electrical measurements.

  6. Computational modeling of heat transfer and visco-plastic flow in friction stir welding

    NASA Astrophysics Data System (ADS)

    Nandan, Rituraj

    With a focus to develop a quantitative understanding of the FSW process, a comprehensive three dimensional heat transfer and plastic flow model is developed. The model can predict variables such as temperature and velocity fields and torque based on the given welding parameters like weld velocity, tool rotational speed and axial pressure. It considers tool design dependent spatially variable heat generation rates, deformational work, non-Newtonian viscosity as a function of local strain rate, temperature and the nature of the material and temperature dependent thermal conductivity, specific heat capacity and yield stress. It is shown that the temperature fields, cooling rates, the plastic flow fields and the geometry of the thermo-mechanically affected zone (TMAZ) can be adequately described by solving the equations of conservation of mass, momentum and energy in three dimensions with appropriate boundary conditions and constitutive equations for viscosity. The model is tested for four different alloys: (1) AA 6061-T6, (2) 1018 Mn steel, (3) 304L stainless steel and (4) Ti-6Al-4V which have widely different thermophysical and rheological properties. Numerically computed temperature fields, variations of peak temperatures with FSW variables and TMAZ geometry were compared with the experimental results. Currently, due to unknown parameters in existing transport phenomena based models, the computed temperature and velocity fields and torque may not always agree with the corresponding experimentally determined values and may not show the same trend as experimental results for a range of welding variables. Here, it is shown that this problem can be solved by combining the rigorous phenomenological process sub-model with a multivariable optimization scheme called Differential Evolution. The values of the uncertain model input parameters from a limited volume of independent experimental data which includes temperature measurements obtained using thermocouples and torque measured using dynamometers. This approach resulted in agreement between the phenomenological model and the experimental results with a greater degree of certainty. It is tested for FSW of: (1) dissimilar AA 6061-T6 to AA 1200, (2) 1018 Mn steel and (3) Ti-6Al-4V. Independent thermocouple and dynamometer measurements are also used for validation and verification of results. Improvement in the reliability of the numerical model is an important first step towards increasing its practical usefulness. Also, one of the reasons why current models do not find extensive applications is because they cannot be used to tailor weld attributes. The aim of the present research is to develop a reliable bi-directional model which can find wide use in manufacturing and process control. It is shown that by coupling a reliable model with an evolutionary search algorithm, we can find multiple sets of welding parameters to achieve a target peak temperature and cooling rate in welds. The model is tested for dissimilar welds of AA 6351 and AA 1200. FSW is being increasingly used for dissimilar metal joining. Models are needed to calculate the redistribution of alloying elements when two alloys with dissimilar alloying element contents are joined. The transport and mixing of magnesium from Mg-rich AA 6061 alloy into a commercially pure aluminum AA 1200 was examined experimentally and numerically at various locations in the welded workpiece. The concentration of the solute is measured in transverse cross-sections across the weld-center line at various depths from the top surface of the workpiece. The measurement was done using electron probe micro-analysis (EPMA) of polished transverse-cut friction-stir welded samples. The comparison of the experimental and computed concentration profiles of magnesium shows imperfect mixing of the plasticized alloys during FSW. The plasticized material seem to move in layers without significant diffusive interlayer mixing. A comprehensive model for FSW is developed with capability of calculating temperature fields, material flow patterns and concentration fields in both similar and dissimilar welds in three dimensions. The model is tested for the FSW of alloys with widely different thermophysical properties. A mechanism for improving reliability and ability to provide guidance to tailor weld attributes is incorporated into the model to increase its practical usefulness. This is done by by combining the transport phenomena based model with Differential Evolution algorithm to minimize the objective function based on limited volume of experimental thermal cycles and torque measurements. (Abstract shortened by UMI.)

  7. A pressure-based force and torque prediction technique for the study of fish-like swimming

    PubMed Central

    Dabiri, John O.; Lauder, George V.

    2017-01-01

    Many outstanding questions about the evolution and function of fish morphology are linked to swimming dynamics, and a detailed knowledge of time-varying forces and torques along the animal’s body is a key component in answering many of these questions. Yet, quantifying these forces and torques experimentally represents a major challenge that to date prevents a full understanding of fish-like swimming. Here, we develop a method for obtaining these force and torque data non-invasively using standard 2D digital particle image velocimetry in conjunction with a pressure field algorithm. We use a mechanical flapping foil apparatus to model fish-like swimming and measure forces and torques directly with a load cell, and compare these measured values to those estimated simultaneously using our pressure-based approach. We demonstrate that, when out-of-plane flows are relatively small compared to the planar flow, and when pressure effects sufficiently dominate shear effects, this technique is able to accurately reproduce the shape, magnitude, and timing of locomotor forces and torques experienced by a fish-like swimmer. We conclude by exploring of the limits of this approach and its feasibility in the study of freely-swimming fishes. PMID:29216264

  8. [Nutritional evaluation and physical functional ability in scleroderma patients].

    PubMed

    Azevedo, Valderilio Feijó; Müller, Carolina de Souza; Rinaldi, Luciane; Bredt, Murilo Cézar; Giovanni, Karizianni; Pereira, Marcela Abou Chami; Volaco, Fernanda Copabianco

    2009-01-01

    Systemic Sclerosis (SSc) is an inflammatory disease that decreases functional capacity through muscular atrophy, skin sclerosis and loss of joint function. Scleroderma patients suffer from movement's restriction. In addition, the disease affects the nutritional status, compromising the quality of life in varying degrees. The gastrointestinal involvement appears to be the main responsible for the nutritional impairment. To evaluate the physical and nutritional status of patients with SSc. We conducted a cross-sectional and descriptive study in 20 patients with SSc. All patients were evaluated in Physioteraphy Clinic of the Catholic University of Paraná, from July 2003 to April 2004. The evaluation was performed by Bioimpedance Body (BIA), the questionnaires Nutritional Risk Assessment (Determine), Mini Nutritional Assessment of Aging and Health Assessment Questionnaire (HAQ) and Visual Analogue Scale (VAS) for pain. The work muscle ability was assessed by measuring the peak torque of flexor and extensor muscles of the elbow in the isokinetic dynamometer Cybex Norm model 7000. We have calculated the mean and standard deviation for each variable analyzed, in addition to the percentage of peak torque deficit. The values of the VAS ranged from zero to 97.8 mm (mean: 48.9 +/- 32.9 mm). The HAQ scores ranged from zero to 2.75 (average: 0.95 +/- 0.8). The average BMI was 22.4 +/- 3.9 kg / m2. The average deficit of mass was: 1.3 +/- 2.1 kg. Ten patients had high nutritional risk. 1 patient was malnourished and 15 were at high risk for malnutrition. The average peak torque to the muscle groups of elbows was 19.2 +/- 5 N / m to the flexor and 21.9 +/-6.6 N/m for the extensors, with an average deficit of 17% and 13% for the both groups. We found that SSc patients were in poor nutritional status and had decreased functional and physical capacity by the weakening of the muscles of the elbow demonstrated by the isokinetic evaluation. We concluded that our SSc patients were at high risk for malnutrition and this may indicate that scleroderma patients need a better nutritional orientation. We do consider that SSc patients also must be included in physical activity programs in order to achieve better physical performance.

  9. Highway Vehicle Retrofit Evaluation : Phase 2. Report. Testing and Final Evaluation Results.

    DOT National Transportation Integrated Search

    1976-11-01

    This report presents the results of engine dynamometer and vehicle chassis dynamometer tests conducted with selected automotive retrofit devices in the classes of ultrasonic carburetors, high-velocity intake manifolds, tuned exhaust systems, and high...

  10. The Martin Vigorimeter Represents a Reliable and More Practical Tool Than the Jamar Dynamometer to Assess Handgrip Strength in the Geriatric Patient.

    PubMed

    Sipers, Walther M W H; Verdijk, Lex B; Sipers, Simone J E; Schols, Jos M G A; van Loon, Luc J C

    2016-05-01

    Geriatric patients with low skeletal muscle mass and strength generally have a relatively poor clinical outcome following acute illness. Therefore, it is recommended to routinely assess skeletal muscle mass and strength in patients admitted to the acute care geriatric ward. Handgrip strength is generally measured as a proxy for muscle strength and/or functional performance. To compare the applicability and test-retest reliability of measuring handgrip strength using the Jamar dynamometer and the Martin Vigorimeter in geriatric patients during hospitalization. A total of 96 geriatric patients (age 85 ± 5 y) admitted to the acute care geriatric ward participated in this study. Handgrip strength was assessed 3 times on 2 different occasions within 1 week of hospital admission using both the Jamar dynamometer and the Martin Vigorimeter. Maximal handgrip strength as determined over the 3 successive attempts performed on 2 occasions averaged 17 ± 7 kg and 35 ± 13 kPa when using the Jamar dynamometer and Martin Vigorimeter, respectively. Handgrip strength was significantly greater when using the dominant versus nondominant hand using both the Jamar dynamometer (17 ± 7 kg vs 16 ± 7 kg; P = .003) and Martin Vigorimeter (34 ± 12 kPa vs 33 ± 13 kPa; P = .022). Test-retest reliability showed an ICC of 0.94 and 0.92 when applying the Jamar dynamometer or Martin Vigorimeter, respectively (both P < .001). Furthermore, handgrip strength assessed with the Jamar and Martin Vigorimeter showed a strong correlation for both the first (ρ = 0.83, P < .001) and second measurement (ρ = 0.79, P < .001). Almost 80% of the geriatric patients needed help from nursing staff with transfer from bed to an arm-rested chair measuring handgrip strength with the Jamar dynamometer according to the Southampton protocol, which is not necessary when using the Martin Vigorimeter. The Martin Vigorimeter represents a reliable and more practical tool than the Jamar dynamometer to assess handgrip strength in the geriatric patient on admission to the acute geriatric ward. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  11. Torque undergone by assemblies of single-domain magnetic nanoparticles submitted to a rotating magnetic field

    NASA Astrophysics Data System (ADS)

    Carrey, J.; Hallali, N.

    2016-11-01

    In the last 10 years, it has been shown in various types of experiments that it is possible to induce biological effects in cells using the torque generated by magnetic nanoparticles submitted to an alternating or a rotating magnetic field. In biological systems, particles are generally found under the form of assemblies because they accumulate at the cell membrane, are internalized inside lysosomes, or are synthesized under the form of beads containing several particles. The torque undergone by assemblies of single-domain magnetic nanoparticles has not been addressed theoretically so far and is the subject of the present article. The results shown in the present article have been obtained using kinetic Monte Carlo simulations, in which thermal activation is taken into account, so the torque undergone by ferromagnetic and superparamagnetic nanoparticles could both be simulated. The first system under study is a single ferromagnetic particle with its easy axis in the plane of the rotating magnetic field. Then, elements adding complexity to the problem are introduced progressively and the properties of the resulting system presented and analyzed: random anisotropy axes, thermal activation, assemblies, and finally magnetic interactions. The most complex studied systems are particularly relevant for applications and are assemblies of interacting superparamagnetic nanoparticles with randomly oriented anisotropy axes. Whenever it is possible, analytical equations describing the torque properties are provided, as well as their domain of validity. Although the properties of an assembly naturally derive from those of single particles, it is shown here that several of them were unexpected and are particularly interesting with regard to the maximization of torque amplitude in biological applications. In particular, it is shown that, in a given range of parameters, the torque of an assembly increases dramatically in the direction perpendicular to the plane of the rotating magnetic field. This effect results from a breaking of time reversal symmetry when the field is rotated and is comprehensively explained. This strong enhancement occurs only if the magnetic field rotates, not if it oscillates. When this enhancement does not occur, the total torque of an assembly scales with the square root of the number of particles in the assembly. In the enhancement regime, the total torque scales with a power exponent larger than 1/2. It is also found that, in superparamagnetic nanoparticles, this enhancement is induced by the presence of magnetic interactions so that, in a rather large range of parameters, interacting superparamagnetic particles display a much larger torque than otherwise identical ferromagnetic particles. In all cases studied, the conditions required to obtain this enhancement are provided. The concepts presented in this article should help chemists and biologists in synthesizing nano-objects with optimized torque properties. For physicists, it would be interesting to test experimentally the results described in this article. For this purpose, torque measurements on well-characterized assemblies of nanoparticles should be performed and compared with numerical simulations.

  12. Component qualification and initial build of the AGT 100 advanced automotive gas turbine

    NASA Technical Reports Server (NTRS)

    Johnson, R. A.

    1983-01-01

    In advance of initial dynamometer testing of the AGT 100 engine, all prime components and subsystems were bench/rig tested. Included were compressor, combustor, turbines, regenerator, ceramic components, and electronic control system. Results are briefly reviewed. Initial engine buildup was completed and rolled-out for test cell installation in July 1982. Shakedown testing included motoring and sequential firing of the combustor's three fuel nozzles.

  13. 40 CFR 1066.210 - Dynamometers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... chassis dynamometer typically uses electrically generated load forces combined with its rotational inertia... (known as “road load”). Load forces are calculated using vehicle-specific coefficients and response characteristics. The load forces are applied to the vehicle tires by rolls connected to intermediate motor...

  14. 40 CFR 1066.210 - Dynamometers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... chassis dynamometer typically uses electrically generated load forces combined with its rotational inertia... (known as “road load”). Load forces are calculated using vehicle-specific coefficients and response characteristics. The load forces are applied to the vehicle tires by rolls connected to intermediate motor...

  15. Reliability and Validity of a New Method for Isometric Back Extensor Strength Evaluation Using A Hand-Held Dynamometer.

    PubMed

    Park, Hee-Won; Baek, Sora; Kim, Hong Young; Park, Jung-Gyoo; Kang, Eun Kyoung

    2017-10-01

    To investigate the reliability and validity of a new method for isometric back extensor strength measurement using a portable dynamometer. A chair equipped with a small portable dynamometer was designed (Power Track II Commander Muscle Tester). A total of 15 men (mean age, 34.8±7.5 years) and 15 women (mean age, 33.1±5.5 years) with no current back problems or previous history of back surgery were recruited. Subjects were asked to push the back of the chair while seated, and their isometric back extensor strength was measured by the portable dynamometer. Test-retest reliability was assessed with intraclass correlation coefficient (ICC). For the validity assessment, isometric back extensor strength of all subjects was measured by a widely used physical performance evaluation instrument, BTE PrimusRS system. The limit of agreement (LoA) from the Bland-Altman plot was evaluated between two methods. The test-retest reliability was excellent (ICC=0.82; 95% confidence interval, 0.65-0.91). The Bland-Altman plots demonstrated acceptable agreement between the two methods: the lower 95% LoA was -63.1 N and the upper 95% LoA was 61.1 N. This study shows that isometric back extensor strength measurement using a portable dynamometer has good reliability and validity.

  16. In-line drivetrain and four wheel drive work machine using same

    DOEpatents

    Hoff, Brian

    2008-08-05

    A four wheel drive articulated mine loader is powered by a fuel cell and propelled by a single electric motor. The drivetrain has the first axle, second axle, and motor arranged in series on the work machine chassis. Torque is carried from the electric motor to the back differential via a pinion meshed with the ring gear of the back differential. A second pinion oriented in an opposite direction away from the ring gear is coupled to a drive shaft to transfer torque from the ring gear to the differential of the front axle. Thus, the ring gear of the back differential acts both to receive torque from the motor and to transfer torque to the forward axle. The in-line drive configuration includes a single electric motor and a single reduction gear to power the four wheel drive mine loader.

  17. Real-Time Measurement of Machine Efficiency during Inertia Friction Welding.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tung, Daniel Joseph; Mahaffey, David; Senkov, Oleg

    Process efficiency is a crucial parameter for inertia friction welding (IFW) that is largely unknown at the present time. A new method has been developed to determine the transient profile of the IFW process efficiency by comparing the workpiece torque used to heat and deform the joint region to the total torque. Particularly, the former is measured by a torque load cell attached to the non-rotating workpiece while the latter is calculated from the deceleration rate of flywheel rotation. The experimentally-measured process efficiency for IFW of AISI 1018 steel rods is validated independently by the upset length estimated from anmore » analytical equation of heat balance and the flash profile calculated from a finite element based thermal stress model. The transient behaviors of torque and efficiency during IFW are discussed based on the energy loss to machine bearings and the bond formation at the joint interface.« less

  18. 40 CFR 85.2229 - Dynamometer-EPA 81.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Dynamometer-EPA 81. 85.2229 Section 85.2229 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED....2229 Dynamometer—EPA 81. (a) Applicability. The requirements of this subsection apply to short tests...

  19. 40 CFR 85.2229 - Dynamometer-EPA 81.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Dynamometer-EPA 81. 85.2229 Section 85.2229 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED....2229 Dynamometer—EPA 81. (a) Applicability. The requirements of this subsection apply to short tests...

  20. 40 CFR 85.2229 - Dynamometer-EPA 81.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Dynamometer-EPA 81. 85.2229 Section 85.2229 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED....2229 Dynamometer—EPA 81. (a) Applicability. The requirements of this subsection apply to short tests...

  1. 40 CFR 86.135-90 - Dynamometer procedure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and methanol-fueled Otto-cycle vehicles. The dynamometer run consists of two tests, a “cold” start... analyzed for hydrocarbon, carbon monoxide, carbon dioxide, and oxides of nitrogen. Methanol and formaldehyde samples (exhaust and dilution air) are collected and analyzed for methanol-fueled vehicles (a...

  2. 40 CFR 86.135-90 - Dynamometer procedure.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and methanol-fueled Otto-cycle vehicles. The dynamometer run consists of two tests, a “cold” start... analyzed for hydrocarbon, carbon monoxide, carbon dioxide, and oxides of nitrogen. Methanol and formaldehyde samples (exhaust and dilution air) are collected and analyzed for methanol-fueled vehicles (a...

  3. 40 CFR 1066.250 - Base inertia verification.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Base inertia verification. 1066.250... CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.250 Base inertia verification. (a) Overview. This section describes how to verify the dynamometer's base inertia. (b) Scope and frequency...

  4. 40 CFR 1066.250 - Base inertia verification.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Base inertia verification. 1066.250... CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.250 Base inertia verification. (a) Overview. This section describes how to verify the dynamometer's base inertia. (b) Scope and frequency...

  5. 40 CFR 1066.250 - Base inertia verification.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Base inertia verification. 1066.250... CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.250 Base inertia verification. (a) Overview. This section describes how to verify the dynamometer's base inertia. (b) Scope and frequency...

  6. The Dynamometer Hub for the Testing Propellers and Engines During Flight

    NASA Technical Reports Server (NTRS)

    Enoch, O

    1921-01-01

    The need for a device to measure flight resistance, engine and propeller power, and efficiency during flight grew in proportion to the demand for increased flying capacity in military types of aircraft. Here, a dynamometer hub was inserted between the engine and the propeller. Taken as a whole, the tests that were conducted show that though the dynamometer is a sensitive instrument liable to numerous derangements, it is undeniably useful even in its present form, when handled with care and skill. Facilitating, as it does, the possibility of maintaining the fixed position of the engine, the blocking out of the weight effect when the plane is in the sloping position, and the possibility of taking direct measurements of force at the point of transmission, the dynamometer appears to be by far the best solution of the problem of a flying test bench, utilized as a hydraulic balance with the smallest possible measuring stroke and the least tendency to oscillation.

  7. Reference Values of Grip Strength, Prevalence of Low Grip Strength, and Factors Affecting Grip Strength Values in Chinese Adults.

    PubMed

    Yu, Ruby; Ong, Sherlin; Cheung, Osbert; Leung, Jason; Woo, Jean

    2017-06-01

    The objectives of this study were to update the reference values of grip strength, to estimate the prevalence of low grip strength, and to examine the impact of different aspects of measurement protocol on grip strength values in Chinese adults. A cross-sectional survey of Chinese men (n = 714) and women (n = 4014) aged 18-102 years was undertaken in different community settings in Hong Kong. Grip strength was measured with a digital dynamometer (TKK 5401 Grip-D; Takei, Niigata, Japan). Low grip strength was defined as grip strength 2 standard deviations or more below the mean for young adults. The effects of measurement protocol on grip strength values were examined in a subsample of 45 men and women with repeated measures of grip strength taken with a hydraulic dynamometer (Baseline; Fabrication Enterprises Inc, Irvington, NY), using pair t-tests, intraclass correlation coefficient, and Bland and Altman plots. Grip strength was greater among men than among women (P < .001) and the rate of decline differed between sexes (P < .001). The prevalence of low grip strength also increased with age, reaching a rate of 16.5% in men and 20.6% in women aged 65+. Although the TKK digital dynamometer gave higher grip strength values than the Baseline hydraulic dynamometer (P < .001), the degree of agreement between the 2 dynamometers was satisfactory. Higher grip strength values were also observed when the measurement was performed with the elbow extended in a standing position, compared with that with the elbow flexed at 90° in a sitting position, using the same dynamometer (P < .05). This study updated the reference values of grip strength and estimated the prevalence of low grip strength among Chinese adults spanning a wide age range. These findings might be useful for risk estimation and evaluation of interventions. However, grip strength measurements should be interpreted with caution, as grip strength values can be affected by type of dynamometer used, assessment posture, and elbow position. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  8. The DOE ETV-1 Electric Test Vehicle. Phase 3: Performance Testing and system evaluation

    NASA Technical Reports Server (NTRS)

    Kurtz, D.

    1981-01-01

    Engineering tests were conducted in order to characterize overall system performance and component efficiencies within the system environment. A dynamometer was used in order to minimize the ambient effects and large uncertainties present in track testing. Extensive test requirements were defined and procedures were carefully controlled in order to maintain a high degree of credibility. Limited track testing was performed in order to corroborate the dynamometer results. Test results include an energy flow analysis through the major subsystems and incorporate the aerodynamic and rolling losses under cyclic and various steady speed conditions. The major output from all relevant dynamometer and track tests is also included.

  9. 40 CFR 86.162-00 - Approval of alternative air conditioning test simulations and descriptions of AC1 and AC2.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... power requirements to roadload dynamometer requirements. AC2 simulates, in standard test cell ambient...)(i) (A) and (B) are replaced with 76 °F and 50 grains of water/pound of dry air and the solar heat...)(5)(i) (A) and (B) are replaced with 76 °F and 50 grains of water/pound of dry air and the solar heat...

  10. 40 CFR 86.162-00 - Approval of alternative air conditioning test simulations and descriptions of AC1 and AC2.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... power requirements to roadload dynamometer requirements. AC2 simulates, in standard test cell ambient...)(i) (A) and (B) are replaced with 76 °F and 50 grains of water/pound of dry air and the solar heat...)(5)(i) (A) and (B) are replaced with 76 °F and 50 grains of water/pound of dry air and the solar heat...

  11. 40 CFR 86.1318-84 - Engine dynamometer system calibrations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Engine dynamometer system calibrations...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate...

  12. 40 CFR 86.218-94 - Dynamometer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.218-94 Dynamometer calibration. The...

  13. 40 CFR 86.1337-2007 - Engine dynamometer test run.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... engine, dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. (2..., loaded particulate sample filter cartridge into the filter holder assembly. It is recommended that this be done within the filter stabilization environment, with both ends of the filter holder assembly...

  14. 40 CFR 86.1337-2007 - Engine dynamometer test run.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... engine, dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. (2..., loaded particulate sample filter cartridge into the filter holder assembly. It is recommended that this be done within the filter stabilization environment, with both ends of the filter holder assembly...

  15. 40 CFR 86.1337-2007 - Engine dynamometer test run.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... engine, dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. (2..., loaded particulate sample filter cartridge into the filter holder assembly. It is recommended that this be done within the filter stabilization environment, with both ends of the filter holder assembly...

  16. 40 CFR 86.1337-2007 - Engine dynamometer test run.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... engine, dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. (2..., loaded particulate sample filter cartridge into the filter holder assembly. It is recommended that this be done within the filter stabilization environment, with both ends of the filter holder assembly...

  17. 40 CFR 86.1318-84 - Engine dynamometer system calibrations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Engine dynamometer system calibrations...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate...

  18. 40 CFR 86.1318-84 - Engine dynamometer system calibrations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Engine dynamometer system calibrations...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate...

  19. 40 CFR 86.1318-84 - Engine dynamometer system calibrations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Engine dynamometer system calibrations...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate...

  20. Reliability and Validity of a New Method for Isometric Back Extensor Strength Evaluation Using A Hand-Held Dynamometer

    PubMed Central

    2017-01-01

    Objective To investigate the reliability and validity of a new method for isometric back extensor strength measurement using a portable dynamometer. Methods A chair equipped with a small portable dynamometer was designed (Power Track II Commander Muscle Tester). A total of 15 men (mean age, 34.8±7.5 years) and 15 women (mean age, 33.1±5.5 years) with no current back problems or previous history of back surgery were recruited. Subjects were asked to push the back of the chair while seated, and their isometric back extensor strength was measured by the portable dynamometer. Test-retest reliability was assessed with intraclass correlation coefficient (ICC). For the validity assessment, isometric back extensor strength of all subjects was measured by a widely used physical performance evaluation instrument, BTE PrimusRS system. The limit of agreement (LoA) from the Bland-Altman plot was evaluated between two methods. Results The test-retest reliability was excellent (ICC=0.82; 95% confidence interval, 0.65–0.91). The Bland-Altman plots demonstrated acceptable agreement between the two methods: the lower 95% LoA was −63.1 N and the upper 95% LoA was 61.1 N. Conclusion This study shows that isometric back extensor strength measurement using a portable dynamometer has good reliability and validity. PMID:29201818

  1. Agonist muscle adaptation accompanied by antagonist muscle atrophy in the hindlimb of mice following stretch-shortening contraction training.

    PubMed

    Rader, Erik P; Naimo, Marshall A; Ensey, James; Baker, Brent A

    2017-02-02

    The vast majority of dynamometer-based animal models for investigation of the response to chronic muscle contraction exposure has been limited to analysis of isometric, lengthening, or shortening contractions in isolation. An exception to this has been the utilization of a rat model to study stretch-shortening contractions (SSCs), a sequence of consecutive isometric, lengthening, and shortening contractions common during daily activity and resistance-type exercise. However, the availability of diverse genetic strains of rats is limited. Therefore, the purpose of the present study was to develop a dynamometer-based SSC training protocol to induce increased muscle mass and performance in plantarflexor muscles of mice. Young (3 months old) C57BL/6 mice were subjected to 1 month of plantarflexion SSC training. Hindlimb muscles were analyzed for muscle mass, quantitative morphology, myogenesis/myopathy relevant gene expression, and fiber type distribution. The main aim of the research was achieved when training induced a 2-fold increase in plantarflexion peak torque output and a 19% increase in muscle mass for the agonist plantaris (PLT) muscle. In establishing this model, several outcomes emerged which raised the value of the model past that of being a mere recapitulation of the rat model. An increase in the number of muscle fibers per transverse muscle section accounted for the PLT muscle mass gain while the antagonist tibialis anterior (TA) muscle atrophied by 30% with preferential atrophy of type IIb and IIx fibers. These alterations were accompanied by distinct gene expression profiles. The findings confirm the development of a stretch-shortening contraction training model for the PLT muscle of mice and demonstrate that increased cross-sectional fiber number can occur following high-intensity SSC training. Furthermore, the TA muscle atrophy provides direct evidence for the concept of muscle imbalance in phasic non-weight bearing muscles, a concept largely characterized based on clinical observation of patients. The susceptibility to this imbalance is demonstrated to be selective for the type IIb and IIx muscle fiber types. Overall, the study highlights the importance of considering muscle fiber number modulation and the effect of training on surrounding muscles in exercise comprised of SSCs.

  2. Power reserve following ramp-incremental cycling to exhaustion: implications for muscle fatigue and function.

    PubMed

    Hodgson, Michael D; Keir, Daniel A; Copithorne, David B; Rice, Charles L; Kowalchuk, John M

    2018-04-26

    In ramp-incremental cycling exercise, some individuals are capable of producing power output (PO) in excess of that produced at their limit of tolerance (LoT) while others cannot. This study sought to describe the: 1) prevalence of a "power reserve" within a group of young men (n=21; mean {plus minus} SD: age 25{plus minus}4 years; V̇O 2max 45{plus minus}8 ml•kg -1 •min -1 ); and 2) muscle fatigue characteristics of those with and without a power reserve. Power reserve was determined as the difference between peak PO achieved during a ramp-incremental test to exhaustion and maximal, single-leg isokinetic dynamometer power. Pre- versus post-exercise changes in voluntary and electrically-stimulated single-leg muscle force production measures (maximal voluntary contraction, voluntary activation, maximal isotonic velocity and isokinetic power; 1-, 10-, 50-Hz torque and 10/50-Hz ratio), V̇O 2max and constant-PO cycling time-to-exhaustion also were assessed. A dichotomy in power reserve was prevalent within the sample resulting in two groups: 1) "No Reserve" (NRES: <5% reserve; n=10) and 2) "Reserve" (RES: >15% reserve; n=11). At the LoT, all participants had achieved V̇O 2max . Muscle fatigue was evident in both groups, although the NRES group had greater reductions (p<0.05) in 10-Hz peak torque (PT), 10/50 Hz ratio, and maximal velocity. Time-to-exhaustion during the constant-PO test was 22{plus minus}16% greater (p<0.05) in RES (116{plus minus}19 s; PO = 317{plus minus}52 W) than in NRES (90{plus minus}23 s; PO = 337{plus minus}71 W), despite similar ramp-incremental exercise durations and V̇O 2max between groups. The differences in muscle fatigue and function between groups suggest that the mechanisms contributing to the LoT are not uniform.

  3. Knee and ankle strength and lower extremity power in adolescent female ballet dancers.

    PubMed

    Kenne, Ellinor; Unnithan, Viswanath B

    2008-01-01

    The aims of this study were twofold: (1) to compare the strength of four muscle groups of the lower limb (quadriceps [Q], hamstrings [H], plantar flexors [PF], and dorsiflexors [DF]) between female adolescent ballet dancers (BALs) and basketball players (BBs) over three angular velocities (30 degrees, 60 degrees and 90 degrees/sec) and two types of contraction (eccentric and concentric); and (2) to compare peak and mean power between the BALs and BBs. Eleven BALs (age: 15.8 +/- 1.2 years; stature: 163.9 +/- 6.2 cm; body mass: 56.3 +/- 5.7 kg; Tanner stage 4: N=10, stage 5: N=1) and ten BBs (age: 15.8 +/- 1.0 years; stature: 172.5 +/- 5.8 cm; body mass: 63.2 +/- 10.0 kg; Tanner stage 4: N=7, stage 5: N=3) volunteered to participate. Each participant performed one habituation session and one testing session on a Biodex isokinetic dynamometer to determine peak torque. Three angular velocities (30 degrees, 60 degrees and 90 degrees/sec) were used for each muscle group. To determine absolute and relative peak and mean power, participants performed a 30 second anaerobic Wingate test on a cycle ergometer. There were no significant differences in peak torque for Q, H, PF, and DF between the groups. Basketball players produced greater absolute peak power [569.7 +/- 82.2 vs. 454.6 +/- 79.3 W (p < .05)], relative peak power [9.1 +/- 1.3 vs. 8.1 +/- 1.0 W/kg body mass (p < .05)], absolute mean power [428.4 +/- 53.9 vs. 333.7 +/- 68.2 W (p < .05)] and relative mean power [6.83 +/- 0.7 vs. 5.9 +/- 0.7 W/kg (p < .05)] than BALs. Ballet dancers and BBs had similar isokinetically measured lower extremity muscular strength, but BALs generated lower levels of peak power and mean power compared to BBs.

  4. Knee Proprioception and Strength and Landing Kinematics During a Single-Leg Stop-Jump Task

    PubMed Central

    Nagai, Takashi; Sell, Timothy C; House, Anthony J; Abt, John P; Lephart, Scott M

    2013-01-01

    Context The importance of the sensorimotor system in maintaining a stable knee joint has been recognized. As individual entities, knee-joint proprioception, landing kinematics, and knee muscles play important roles in functional joint stability. Preventing knee injuries during dynamic tasks requires accurate proprioceptive information and adequate muscular strength. Few investigators have evaluated the relationship between knee proprioception and strength and landing kinematics. Objective To examine the relationship between knee proprioception and strength and landing kinematics. Design Cross-sectional study. Setting University research laboratory. Patients or Other Participants Fifty physically active men (age = 26.4 ± 5.8 years, height = 176.5 ± 8.0 cm, mass = 79.8 ± 16.6 kg). Intervention(s) Three tests were performed. Knee conscious proprioception was evaluated via threshold to detect passive motion (TTDPM). Knee strength was evaluated with a dynamometer. A 3-dimensional biomechanical analysis of a single-legged stop-jump task was used to calculate initial contact (IC) knee-flexion angle and knee-flexion excursion. Main Outcome Measure(s) The TTDPM toward knee flexion and extension, peak knee flexion and extension torque, and IC knee-flexion angle and knee flexion excursion. Linear correlation and stepwise multiple linear regression analyses were used to evaluate the relationships of both proprioception and strength against landing kinematics. The α level was set a priori at .05. Results Enhanced TTDPM and greater knee strength were positively correlated with greater IC knee-flexion angle (r range = 0.281–0.479, P range = .001–.048). The regression analysis revealed that 27.4% of the variance in IC knee-flexion angle could be accounted for by knee-flexion peak torque and TTDPM toward flexion (P = .001). Conclusions The current research highlighted the relationship between knee proprioception and strength and landing kinematics. Individuals with enhanced proprioception and muscular strength had better control of IC knee-flexion angle during a dynamic task. PMID:23672323

  5. A numerical analysis of forces exerted by laminar flow on spreading cells in a parallel plate flow chamber assay.

    PubMed

    Olivier, L A; Truskey, G A

    1993-10-01

    Exposure of spreading anchorage-dependent cells to laminar flow is a common technique to measure the strength of cell adhesion. Since cells protrude into the flow stream, the force exerted by the fluid on the cells is a function of cell shape. To assess the relationship between cell shape and the hydrodynamic force on adherent cells, we obtained numerical solutions of the velocity and stress fields around bovine aortic endothelial cells during various stages of spreading and calculated the force required to detach the cells. Morphometric parameters were obtained from light and scanning electron microscopy measurements. Cells were assumed to have a constant volume, but the surface area increased during spreading until the membrane was stretched taut. Two-dimensional models of steady flow were generated using the software packages ANSYS (mesh generation) and FIDAP (problem solution). The validity of the numerical results was tested by comparison with published results for a semicircle in contact with the surface. The drag force and torque were greatest for round cells making initial contact with the surface. During spreading, the drag force and torque declined by factors of 2 and 20, respectively. The calculated forces and moments were used in adhesion models to predict the wall shear stress at which the cells detached. Based upon published values for the bond force and receptor number, round cells should detach at shear stresses between 2.5 and 6 dyn/cm(2), whereas substantially higher stresses are needed to detach spreading and fully spread cells. Results from the simulations indicate that (1) the drag force varies little with cell shape whereas the torque is very sensitive to cell shape, and (2) the increase in the strength of adhesion during spreading is due to increased contact area and receptor densities within the contact area. (c) 1993 John Wiley & Sons, Inc.

  6. 40 CFR 86.208-94 - Dynamometer.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.208-94 Dynamometer. (a) For testing that is...

  7. 40 CFR 86.215-94 - EPA urban dynamometer driving schedule.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.215-94 EPA urban dynamometer...

  8. 40 CFR 86.237-94 - Dynamometer test run, gaseous emissions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.237-94 Dynamometer...

  9. 40 CFR 86.1308-84 - Dynamometer and engine equipment specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Dynamometer and engine equipment... (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate...

  10. 40 CFR 86.1237-85 - Dynamometer runs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Evaporative... or pushed onto the dynamometer; however, if driven, the period of engine operation between the end of... manner that it is not exposed to precipitation (e.g., rain or dew). (b) The following steps shall be...

  11. A comparison of preload values in gold and titanium dental implant retaining screws.

    PubMed

    Doolabh, R; Dullabh, H D; Sykes, L M

    2014-08-01

    This in vitro investigation compared the effect of using either gold or titanium retaining screws on preload in the dental implant- abutment complex. Inadequate preload can result in screw loosening, whilst fracture may occur if preload is excessive. These are the most commonly reported complications in implant-retained prostheses, and result in unscheduled, costly and time-consuming visits for the patient and the clinician. This study investigated changes in preload generation after repeated torque applications to gold and titanium screws. The test set-up consisted of an implant body, a cylindrical transmucosa abutment, and the test samples of gold and of titanium retaining screws. The implant bodies were anchored using a load cell, and the transmucosal abutments were attached using either gold or titanium retaining screws. A torque gauge was used to apply torque of 20Ncm, 32Ncm, and 40Ncm to the retaining screws. The preloads generated in each screw type were compared at each torque setting, and after repeated tightening episodes. In addition, the effect of applying torque beyond the manufacturers' recommendations was also examined. Gold retaining screws were found to achieve consistently higher preload values than titanium retaining screws. Preload values were not significantly different from the first to the tenth torque cycle. Titanium screws showed more consistent preload values, albeit lower than those of the gold screws. However due to possible galling of the internal thread of the implant body by titanium screws, gold screws remain the retaining screw of choice. Based on the findings of this study, gold retaining screws generate better preload than titanium. Torque beyond the manufacturers' recommendations resulted in a more stable implant complex. However, further investigations, with torque applications repeated until screw breakage, are needed to advise on ideal maintenance protocols.

  12. Deformable micro torque swimmer

    NASA Astrophysics Data System (ADS)

    Ishikawa, Takuji; Tanaka, Tomoyuki; Omori, Toshihiro; Imai, Yohsuke

    2015-11-01

    We investigated the deformation of a ciliate swimming freely in a fluid otherwise at rest. The cell body was modeled as a capsule with a hyper elastic membrane enclosing Newtonian fluid. Thrust forces due to the ciliary beat were modeled as torques distributed above the cell body. Effects of the membrane elasticity, the aspect ratio of cell's reference shape and the density difference between the cell and the surrounding fluid were investigated. The results showed that the cell deformed like heart shape when Capillary number (Ca) was sufficiently large, and the swimming velocity decreased as Ca was increased. The gravity effect on the membrane tension suggested that the upwards and downwards swimming velocities of Paramecium might be reglated by the calcium ion channels distributed locally around the anterior end. Moreover, the gravity induced deformation made a cell directed vertically downwards, which resulted in a positive geotaxis like behavior with physical origin. These results are important to understand physiology of ciliate's biological responses to mechanical stimuli.

  13. 40 CFR 86.159-00 - Exhaust emission test procedures for US06 emissions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... from the dynamometer rolls shall be used. A speed vs. time recording, as evidence of dynamometer test... vehicle. In the case of vehicles with rear engine compartments (or if special designs make the above... appropriate throttle action to maintain the proper speed-time relationship, or to permit sampling system...

  14. Dynamometer Research Facilities | Wind | NREL

    Science.gov Websites

    drivetrains by replacing the rotor and blades of a turbine with a powerful motor. The National Renewable -horsepower variable-speed induction motor, with AC grid connections of 120, 240, and 480 volts (V) and a dynamometer features a 3,351-horsepower (hp), 415-amp AC induction motor with variable-frequency drive that

  15. 40 CFR 86.515-78 - EPA urban dynamometer driving schedule.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... I(b) (b) The speed tolerance at any given time on the dynamometer driving schedule prescribed in... than the tolerances (such as may occur during gear changes) are acceptable provided they occur for less... requirements of § 86.532 the speed tolerance shall be as specified above, except that the upper and lower...

  16. 40 CFR 1066.260 - Parasitic friction compensation evaluation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... also first verify the dynamometer's parasitic loss curve as specified in § 1066.255. (c) Procedure. Use...-load coefficients A, B, and C set to 0. Set the dynamometer to speed-control mode with a target speed... friction compensation is executed perfectly, there will be no change in speed during the measurement...

  17. 40 CFR 1066.260 - Parasitic friction compensation evaluation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... also first verify the dynamometer's parasitic loss curve as specified in § 1066.255. (c) Procedure. Use...-load coefficients A, B, and C set to 0. Set the dynamometer to speed-control mode with a target speed... friction compensation is executed perfectly, there will be no change in speed during the measurement...

  18. 40 CFR 1066.260 - Parasitic friction compensation evaluation.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and 1066.240. You must also first verify the dynamometer's parasitic loss curve as specified in § 1066... with the road-load coefficients A, B, and C set to 0. Set the dynamometer to speed-control mode with a... times. If friction compensation is executed perfectly, there will be no change in speed during the...

  19. 40 CFR 86.115-00 - EPA dynamometer driving schedules.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1977 and Later Model Year New Light-Duty Vehicles and New Light-Duty Trucks and New Otto-Cycle... for the EPA Urban Dynamometer Driving Schedule, US06, SC03, and the EPA New York City Cycles are...

  20. 40 CFR 86.115-00 - EPA dynamometer driving schedules.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1977 and Later Model Year New Light-Duty Vehicles and New Light-Duty Trucks and New Otto-Cycle... for the EPA Urban Dynamometer Driving Schedule, US06, SC03, and the EPA New York City Cycles are...

  1. 40 CFR 86.115-00 - EPA dynamometer driving schedules.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1977 and Later Model Year New Light-Duty Vehicles and New Light-Duty Trucks and New Otto-Cycle... for the EPA Urban Dynamometer Driving Schedule, US06, SC03, and the EPA New York City Cycles are...

  2. 40 CFR 86.115-00 - EPA dynamometer driving schedules.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1977 and Later Model Year New Light-Duty Vehicles and New Light-Duty Trucks and New Otto-Cycle... for the EPA Urban Dynamometer Driving Schedule, US06, SC03, and the EPA New York City Cycles are...

  3. Gearbox Reliability Collaborative Analytic Formulation for the Evaluation of Spline Couplings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, Yi; Keller, Jonathan; Errichello, Robert

    2013-12-01

    Gearboxes in wind turbines have not been achieving their expected design life; however, they commonly meet and exceed the design criteria specified in current standards in the gear, bearing, and wind turbine industry as well as third-party certification criteria. The cost of gearbox replacements and rebuilds, as well as the down time associated with these failures, has elevated the cost of wind energy. The National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) was established by the U.S. Department of Energy in 2006; its key goal is to understand the root causes of premature gearbox failures and improve their reliabilitymore » using a combined approach of dynamometer testing, field testing, and modeling. As part of the GRC program, this paper investigates the design of the spline coupling often used in modern wind turbine gearboxes to connect the planetary and helical gear stages. Aside from transmitting the driving torque, another common function of the spline coupling is to allow the sun to float between the planets. The amount the sun can float is determined by the spline design and the sun shaft flexibility subject to the operational loads. Current standards address spline coupling design requirements in varying detail. This report provides additional insight beyond these current standards to quickly evaluate spline coupling designs.« less

  4. Shoulder functional ratio in elite junior tennis players.

    PubMed

    Saccol, Michele Forgiarini; Gracitelli, Guilherme Conforto; da Silva, Rogério Teixeira; Laurino, Cristiano Frota de Souza; Fleury, Anna Maria; Andrade, Marília dos Santos; da Silva, Antonio Carlos

    2010-02-01

    To evaluate shoulder rotation strength and compare the functional ratio between shoulders of elite junior tennis players. This cross-sectional study evaluated muscular rotation performance of 40 junior tennis players (26 male and 14 female) with an isokinetic dynamometer. Strength variables of external (ER) and internal rotators (IR) in concentric and eccentric modes were considered. For the peak torque functional ratio, the eccentric strength of the ER and the concentric strength of the IR were calculated. All variables related to IR were significantly higher on the dominant compared to the non-dominant side in males and females (p<0.05), but only boys exhibited this dominance effect in ER (p<0.05 and p<0.001). Regarding functional ratios, they were significantly lower for the dominant shoulder (p<0.001) and below 1.00 for both groups, indicating that the eccentric strength of the ER was not greater than the concentric strength of the IR. Elite junior tennis players without shoulder injury have shoulder rotation muscle strength imbalances that alter the normal functional ratio between rotator cuff muscles. Although these differences do not seem to affect the athletic performance, detection and prevention with exercise programs at an early age are recommended. Crown Copyright 2009. Published by Elsevier Ltd. All rights reserved.

  5. Reliability of a device for the knee and ankle isometric and isokinetic strength testing in older adults.

    PubMed

    Bergamin, Marco; Gobbo, Stefano; Bullo, Valentina; Vendramin, Barbara; Duregon, Federica; Frizziero, Antonio; Di Blasio, Andrea; Cugusi, Lucia; Zaccaria, Marco; Ermolao, Andrea

    2017-01-01

    Lower extremity muscle mass, strength, power, and physical performance are critical determinants of independent functioning in later life. Isokinetic dynamometers are becoming very common in assessing different features of muscle strength, in both research and clinical practice; however, reliability studies are still needed to support the extended use of those devices. The purpose of this study is to assess the test-retest reliability of knee and ankle isokinetic and isometric strength testing protocols in a sample of older healthy subjects, using a new and untested isokinetic multi-joint evaluation system. Sixteen male and fourteen female older adults (mean age 65.2 ± 4.6 years) were assessed in two testing sessions. Each participant performed a randomized testing procedure that includes different isometric and isokinetic tests for knee and ankle joints. All participants concluded the trial safety and no subject reported any discomfort throughout the overall assessment. Coefficients of correlation between measures were calculated showing moderate to strong effects among all test-retest assessments and paired-sample t test showed only one significant difference (p<0.05) in the maximal isokinetic bilateral knee flexion torque. The multi-joint evaluation system for the assessment of knee and ankle isokinetic and isometric strength provided reliable test-retest measures in healthy older adults. Ib.

  6. Isokinetic Testing in Evaluation Rehabilitation Outcome After ACL Reconstruction.

    PubMed

    Cvjetkovic, Dragana Dragicevic; Bijeljac, Sinisa; Palija, Stanislav; Talic, Goran; Radulovic, Tatjana Nozica; Kosanovic, Milkica Glogovac; Manojlovic, Slavko

    2015-02-01

    Numerous rehab protocols have been used in rehabilitation after ACL reconstruction. Isokinetic testing is an objective way to evaluate dynamic stability of the knee joint that estimates the quality of rehabilitation outcome after ACL reconstruction. Our investigation goal was to show importance of isokinetic testing in evaluation thigh muscle strength in patients which underwent ACL reconstruction and rehabilitation protocol. In prospective study, we evaluated 40 subjects which were divided into two groups. Experimental group consisted of 20 recreational males which underwent ACL reconstruction with hamstring tendon and rehabilitation protocol 6 months before isokinetic testing. Control group (20 subjects) consisted of healthy recreational males. In all subjects knee muscle testing was performed on a Biodex System 4 Pro isokinetic dynamo-meter et velocities of 60°/s and 180°/s. We followed average peak torque to body weight (PT/BW) and classic H/Q ratio. In statistical analysis Student's T test was used. There were statistically significant differences between groups in all evaluated parameters except of the mean value of PT/BW of the quadriceps et velocity of 60°/s (p>0.05). Isokinetic testing of dynamic stabilizers of the knee is need in diagnostic and treatment thigh muscle imbalance. We believe that isokinetic testing is an objective parameter for return to sport activities after ACL reconstruction.

  7. Isokinetic analysis of ankle and ground reaction forces in runners and triathletes

    PubMed Central

    Luna, Natália Mariana Silva; Alonso, Angelica Castilho; Brech, Guilherme Carlos; Mochizuki, Luis; Nakano, Eduardo Yoshio; Greve, Júlia Maria D'Andréa

    2012-01-01

    OBJECTIVE: To analyze and compare the vertical component of ground reaction forces and isokinetic muscle parameters for plantar flexion and dorsiflexion of the ankle between long-distance runners, triathletes, and non-athletes. METHODS: Seventy-five males with a mean age of 30.26 (±6.5) years were divided into three groups: a triathlete group (n = 26), a long-distance runner group (n = 23), and a non-athlete control group. The kinetic parameters were measured during running using a force platform, and the isokinetic parameters were measured using an isokinetic dynamometer. RESULTS: The non-athlete control group and the triathlete group exhibited smaller vertical forces, a greater ground contact time, and a greater application of force during maximum vertical acceleration than the long-distance runner group. The total work (180°/s) was greater in eccentric dorsiflexion and concentric plantar flexion for the non-athlete control group and the triathlete group than the long-distance runner group. The peak torque (60°/s) was greater in eccentric plantar flexion and concentric dorsiflexion for the control group than the athlete groups. CONCLUSIONS: The athlete groups exhibited less muscle strength and resistance than the control group, and the triathletes exhibited less impact and better endurance performance than the runners. PMID:23018298

  8. Evaluating injury risk in first and second league professional Portuguese soccer: muscular strength and asymmetry.

    PubMed

    Carvalho, Alberto; Brown, Scott; Abade, Eduardo

    2016-06-01

    Strength imbalances between the hamstrings and quadriceps are an essential predictor for hamstring strain in soccer. The study aimed to investigate and compare the muscle strength imbalances of professional soccer players of different performance levels. One hundred and fifty nine senior male professional soccer players from first (n = 75) and second league (n = 84) Portuguese clubs participated in this study. Muscle strength was evaluated with a REV9000 isokinetic dynamometer. Maximal peak torque data were used to calculate quadriceps and hamstrings strength during concentric and eccentric actions, bilateral asymmetry, conventional strength ratios and dynamic control ratios. Second league athletes produced slightly lower conventional strength ratios in the right and left legs (ES = 0.22, p = 0.17 and ES = 0.36, p = 0.023, respectively) compared to the first league athletes. No significant differences were found in dynamic control ratios or in bilateral asymmetry among first and second league athletes. These findings do not show a clear link between the competitive level and injury risk in soccer players. However, some of the differences found, particularly in conventional strength ratios, highlight the importance of performing off-season and pre-season strength assessments to prescribe and adjust individual strength training programs among professional soccer players.

  9. Muscle fatigue during intermittent exercise in individuals with mental retardation.

    PubMed

    Zafeiridis, Andreas; Giagazoglou, Paraskevi; Dipla, Konstantina; Salonikidis, Konstantinos; Karra, Chrisanthi; Kellis, Eleftherios

    2010-01-01

    This study examined fatigue profile during intermittent exercise in 10 men with mild to moderate mental retardation (MR) and 10 men without mental retardation (C). They performed 4 x 30s maximal knee extensions and flexions with 1-min rest on an isokinetic dynamometer. Peak torque of flexors (PTFL) and extensors (PTEX), total work (TW), and lactate were measured. Fatigue was calculated as the magnitude of decline (%) in PTFL, PTEX, and TW and as rate of decline (linear slope) in TW from 1st to 4th set. MR had lower PTFL, PTEX, TW, and lactate throughout the protocol than C, while pre-motor time was greater in MR vs. C (p<0.05). MR demonstrated a delayed pattern of reduction in muscular performance. Lower values were observed in MR vs. C in the magnitude of decline for PTEX and TW and the rate of decline for TW. In conclusion, MR exhibit a different fatigue profile during intermittent exercise than C. The lower magnitude and decline rate in neuromuscular performance in MR during intermittent exercise is associated with their lower peak strength, short-term anaerobic capacity, and lactate accumulation. Rehabilitation and sport professionals should consider the differences in fatigue profile when designing intermittent exercise programs for MR. Copyright 2009 Elsevier Ltd. All rights reserved.

  10. Evaluating injury risk in first and second league professional Portuguese soccer: muscular strength and asymmetry

    PubMed Central

    Carvalho, Alberto; Brown, Scott

    2016-01-01

    Abstract Strength imbalances between the hamstrings and quadriceps are an essential predictor for hamstring strain in soccer. The study aimed to investigate and compare the muscle strength imbalances of professional soccer players of different performance levels. One hundred and fifty nine senior male professional soccer players from first (n = 75) and second league (n = 84) Portuguese clubs participated in this study. Muscle strength was evaluated with a REV9000 isokinetic dynamometer. Maximal peak torque data were used to calculate quadriceps and hamstrings strength during concentric and eccentric actions, bilateral asymmetry, conventional strength ratios and dynamic control ratios. Second league athletes produced slightly lower conventional strength ratios in the right and left legs (ES = 0.22, p = 0.17 and ES = 0.36, p = 0.023, respectively) compared to the first league athletes. No significant differences were found in dynamic control ratios or in bilateral asymmetry among first and second league athletes. These findings do not show a clear link between the competitive level and injury risk in soccer players. However, some of the differences found, particularly in conventional strength ratios, highlight the importance of performing off-season and pre-season strength assessments to prescribe and adjust individual strength training programs among professional soccer players. PMID:28149364

  11. A comparison of muscle stiffness and musculoarticular stiffness of the knee joint in young athletic males and females.

    PubMed

    Wang, Dan; De Vito, Giuseppe; Ditroilo, Massimiliano; Fong, Daniel T P; Delahunt, Eamonn

    2015-06-01

    The objective of this study was to investigate the gender-specific differences in peak torque (PT), muscle stiffness (MS) and musculoarticular stiffness (MAS) of the knee joints in a young active population. Twenty-two male and twenty-two female recreational athletes participated. PT of the knee joint extensor musculature was assessed on an isokinetic dynamometer, MS of the vastus lateralis (VL) muscle was measured in both relaxed and contracted conditions, and knee joint MAS was quantified using the free oscillation technique. Significant gender differences were observed for all dependent variables. Females demonstrated less normalized PT (mean difference (MD)=0.4Nm/kg, p=0.005, η(2)=0.17), relaxed MS (MD=94.2N/m, p<.001, η(2)=0.53), contracted MS (MD=162.7N/m, p<.001, η(2)=0.53) and MAS (MD=422.1N/m, p<.001, η(2)=0.23) than males. MAS increased linearly with the external load in both genders with males demonstrating a significantly higher slope (p=0.019) than females. The observed differences outlined above may contribute to the higher knee joint injury incidence and prevalence in females when compared to males. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Investigation of flow in axial turbine stage without shroud-seal

    NASA Astrophysics Data System (ADS)

    Straka, Petr; Němec, Martin; Jelínek, Thomáš

    2015-05-01

    This article deals with investigation of the influence of the radial gaps on the efficiency of the axial turbine stage. The investigation was carried out for the axial stage of the low-power turbine with the drum-type rotor without the shroud. In this configuration the flow through the radial gap under the hub-end of the stator blades and above the tip-end of the rotor blades leads to generation of the strong secondary flows, which decrease the efficiency of the stage. This problem was studied by experiment as well as by numerical modelling. The experiment was performed on the test rig equipped with the water brake dynamometer, torque meter and rotatable stator together with the linear probe manipulator. Numerical modelling was carried out for both the steady flow using the "mixing plane" interface and the unsteady flow using the "sliding mesh" interface between the stator and rotor wheels. The influence of the radial gap was studied in two configuration a) positive and b) negative overlapping of the tip-ends of the rotor blades. The efficiency of the axial stage in dependence on the expansion ratio, velocity ratio and the configuration as well as the details of the flow fields are presented in this paper.

  13. Electromagnetic tweezers with independent force and torque control

    NASA Astrophysics Data System (ADS)

    Jiang, Chang; Lionberger, Troy A.; Wiener, Diane M.; Meyhofer, Edgar

    2016-08-01

    Magnetic tweezers are powerful tools to manipulate and study the mechanical properties of biological molecules and living cells. In this paper we present a novel, bona fide electromagnetic tweezer (EMT) setup that allows independent control of the force and torque applied via micrometer-sized magnetic beads to a molecule under study. We implemented this EMT by combining a single solenoid that generates force (f-EMT) with a set of four solenoids arranged into a symmetric quadrupole to generate torque (τ-EMT). To demonstrate the capability of the tweezers, we attached optically asymmetric Janus beads to single, tethered DNA molecules. We show that tension in the piconewton force range can be applied to single DNA molecules and the molecule can simultaneously be twisted with torques in the piconewton-nanometer range. Furthermore, the EMT allows the two components to be independently controlled. At various force levels applied to the Janus bead, the trap torsional stiffness can be continuously changed simply by varying the current magnitude applied to the τ-EMT. The flexible and independent control of force and torque by the EMT makes it an ideal tool for a range of measurements where tensional and torsional properties need to be studied simultaneously on a molecular or cellular level.

  14. Measurement of plastic and elastic deformation due to third-order torque in self-ligated orthodontic brackets.

    PubMed

    Major, Thomas W; Carey, Jason P; Nobes, David S; Heo, Giseon; Major, Paul W

    2011-09-01

    Control of root torque is often achieved by introducing a twist in a rectangular archwire. The purpose of this study was to investigate third-order torque on different types of self-ligated brackets by analyzing the bracket's elastic and plastic deformations in conjunction with the expressed torque at varying angles of twist. An orthodontic bracket was mounted to a load cell that measured forces and moments in all directions. The wire was twisted in the bracket via a stepper motor, controlled by custom software. Overhead images were taken by a camera through a microscope and processed by using optical correlation to measure deformation. At the maximum torquing angle of 63° with 0.019 × 0.025-in stainless steel wire, the total elastic and plastic deformation values were 0.063, 0.033, and 0.137 mm for Damon Q (Ormco, Orange, Calif), In-Ovation R (GAC, Bohemia, NY), and Speed (Strite Industries, Cambridge, Ontario, Canada), respectively. The total plastic deformation values were 0.015, 0.006, and 0.086 mm, respectively, measured at 0° of unloading. In-Ovation R had the least deformation due to torquing of the 3 investigated bracket types. Damon Q and Speed on average had approximately 2.5 and 14 times greater maximum plastic deformation, respectively, than did In-Ovation R. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  15. Initial development of a device for controlling manually applied forces.

    PubMed

    Waddington, Gordon S; Adams, Roger D

    2007-05-01

    In both simulation and manual therapy studies, substantial variability has been shown when therapists attempt to replicate an applied force. Knowledge about the forces employed during treatment could reduce this variability. In the current project, a prototype for a mobilizing device incorporating a dynamometer was constructed. The prototype device was built around a conventional "hand-grip" dynamometer to give dial visibility during application of mobilizing forces and a moulded handle was used to increase the hand contact surface during force application. The variability of the mobilization forces produced was measured, and ratings of comfort during a simulated spinal mobilization technique were obtained from therapists. Thirty physiotherapists were randomly allocated to apply either: (i) their own estimate of a grade III mobilization force using their hands in a pisiform grip or (ii) a 100N force with the manual therapy dynamometer, and to rate comfort during the performance of both techniques on a 100mm visual analogue scale. Variance in dynamometer-dial-guided force application was always significantly less than the variance in therapist-concept-guided force application. Repeated-measures tests showed that the mean force produced at grade III was not significantly different from 100N, but physiotherapist comfort ratings were found to be significantly greater (P<0.01) when the manual therapy dynamometer was used. Manually applied force variability was significantly less and therapist comfort greater when using a device with visual access to a dial giving immediate force readout.

  16. IMPACT OF GRAVITY LOADING ON POST-STROKE REACHING AND ITS RELATIONSHIP TO WEAKNESS

    PubMed Central

    Beer, Randall F.; Ellis, Michael D.; Holubar, Bradley G.; Dewald, Julius P.A.

    2010-01-01

    The ability to extend the elbow following stroke depends on the magnitude and direction of torques acting at the shoulder. The mechanisms underlying this link remain unclear. The purpose of this study was to evaluate whether the effects of shoulder loading on elbow function were related to weakness or its distribution in the paretic limb. Ten subjects with longstanding hemiparesis performed movements with the arm either passively supported against gravity by an air bearing, or by activation of shoulder muscles. Isometric maximum voluntary torques at the elbow and shoulder were measured using a load cell. The speed and range of elbow extension movements were negatively impacted by actively supporting the paretic limb against gravity. However, the effects of gravity loading were not related to proximal weakness or abnormalities in the elbow flexor–extensor strength balance. The findings support the existence of abnormal descending motor commands that constrain the ability of stroke survivors to generate elbow extension torque in combination with abduction torque at the shoulder. PMID:17486581

  17. Impact of gravity loading on post-stroke reaching and its relationship to weakness.

    PubMed

    Beer, Randall F; Ellis, Michael D; Holubar, Bradley G; Dewald, Julius P A

    2007-08-01

    The ability to extend the elbow following stroke depends on the magnitude and direction of torques acting at the shoulder. The mechanisms underlying this link remain unclear. The purpose of this study was to evaluate whether the effects of shoulder loading on elbow function were related to weakness or its distribution in the paretic limb. Ten subjects with longstanding hemiparesis performed movements with the arm either passively supported against gravity by an air bearing, or by activation of shoulder muscles. Isometric maximum voluntary torques at the elbow and shoulder were measured using a load cell. The speed and range of elbow extension movements were negatively impacted by actively supporting the paretic limb against gravity. However, the effects of gravity loading were not related to proximal weakness or abnormalities in the elbow flexor-extensor strength balance. The findings support the existence of abnormal descending motor commands that constrain the ability of stroke survivors to generate elbow extension torque in combination with abduction torque at the shoulder.

  18. Measurement of the force and torque produced in the calcium response of reactivated rat sperm flagella.

    PubMed

    Moritz, M J; Schmitz, K A; Lindemann, C B

    2001-05-01

    Rat sperm that are demembranated with Triton X-100 and reactivated with Mg-ATP show a strong mechanical response to the presence of free calcium ion. At pCa < 4, the midpiece region of the flagellum develops a strong and sustained curvature that gives the cell the overall appearance of a fishhook [Lindemann and Goltz, 1988: Cell Motil. Cytoskeleton 10:420-431]. In the present study, the force and torque that maintain the calcium-induced hook have been examined quantitatively. In addition, full-length and shortened flagella were manipulated to evaluate the plasticity of the hooks and determined the critical length necessary for maintaining the curvature. The hooks were found to be highly resilient, returning to their original configuration (>95%) after being straightened and released. The results from manipulating the shortened flagella suggest that the force holding the hook in the curved configuration is generated in the basal 60 microm of the flagellum. The force required to straighten the calcium-induced hooks was measured with force-calibrated glass microprobes, and the bending torque was calculated from the measured force. The force and torque required to straighten the flagellum were found to be proportional to the change in curvature of the hooked region of the flagellum, suggesting an elastic-like behavior. The average torque to open the hooks to a straight position was 2.6 (+/-1.4) x 10(-7) dyne x cm (2.6 x 10(-14) N x m) and the apparent stiffness was 4.3 (+/-1.3) x 10(-10) dyne x cm(2) (4.3 x 10(-19) N x m(2)). The stiffness of the hook was determined to be approximately one quarter the rigor stiffness of a rat sperm flagellum measured under comparable conditions.

  19. 40 CFR 86.1336-84 - Engine starting, restarting, and shutdown.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... dynamometer shall be equal (nominal ±0.5 seconds) to the time required with a starter motor. Motoring by the dynamometer shall be terminated not more than one second after the engine starts. The 24 ±1-second free idle... after 15 seconds of cranking, cranking shall cease and the reason for failure to start shall be...

  20. 40 CFR 86.1337-96 - Engine dynamometer test run.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. For a single... sample is lost. A separate leak check is needed. A leak check of a filter assembly that has only one seal ring in contact with the filter media will not detect a leak when tested under vacuum. A pressure leak...

  1. 40 CFR 86.1337-96 - Engine dynamometer test run.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. For a single... sample is lost. A separate leak check is needed. A leak check of a filter assembly that has only one seal ring in contact with the filter media will not detect a leak when tested under vacuum. A pressure leak...

  2. 40 CFR 86.1337-96 - Engine dynamometer test run.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. For a single... sample is lost. A separate leak check is needed. A leak check of a filter assembly that has only one seal ring in contact with the filter media will not detect a leak when tested under vacuum. A pressure leak...

  3. 40 CFR 86.1337-96 - Engine dynamometer test run.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., dynamometer, and sampling system. (iii) Change filters, etc., and leak check as necessary. For a single... sample is lost. A separate leak check is needed. A leak check of a filter assembly that has only one seal ring in contact with the filter media will not detect a leak when tested under vacuum. A pressure leak...

  4. 40 CFR 91.409 - Engine dynamometer test run.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... all pre-test data specified in § 91.405(c). (4) Start the test cycle (see § 91.410) within 10 minutes... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine dynamometer test run. 91.409... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.409...

  5. 40 CFR 91.409 - Engine dynamometer test run.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... all pre-test data specified in § 91.405(c). (4) Start the test cycle (see § 91.410) within 10 minutes... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine dynamometer test run. 91.409... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.409...

  6. 40 CFR 89.407 - Engine dynamometer test run.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Perform the pre-test procedure as specified in § 89.406. (3) Read and record the general test data as... (c)(5)(i) through (iii) of this section. (6) Read and record all pre-test data specified in § 89.405... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine dynamometer test run. 89.407...

  7. 40 CFR 91.409 - Engine dynamometer test run.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... all pre-test data specified in § 91.405(c). (4) Start the test cycle (see § 91.410) within 10 minutes... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine dynamometer test run. 91.409... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.409...

  8. 40 CFR 89.407 - Engine dynamometer test run.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Perform the pre-test procedure as specified in § 89.406. (3) Read and record the general test data as... (c)(5)(i) through (iii) of this section. (6) Read and record all pre-test data specified in § 89.405... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine dynamometer test run. 89.407...

  9. 40 CFR 91.409 - Engine dynamometer test run.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... all pre-test data specified in § 91.405(c). (4) Start the test cycle (see § 91.410) within 10 minutes... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine dynamometer test run. 91.409... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.409...

  10. 40 CFR 89.407 - Engine dynamometer test run.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Perform the pre-test procedure as specified in § 89.406. (3) Read and record the general test data as... (c)(5)(i) through (iii) of this section. (6) Read and record all pre-test data specified in § 89.405... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine dynamometer test run. 89.407...

  11. 40 CFR 91.409 - Engine dynamometer test run.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... all pre-test data specified in § 91.405(c). (4) Start the test cycle (see § 91.410) within 10 minutes... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine dynamometer test run. 91.409... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.409...

  12. 40 CFR 89.407 - Engine dynamometer test run.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Perform the pre-test procedure as specified in § 89.406. (3) Read and record the general test data as... (c)(5)(i) through (iii) of this section. (6) Read and record all pre-test data specified in § 89.405... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine dynamometer test run. 89.407...

  13. 40 CFR 89.407 - Engine dynamometer test run.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Perform the pre-test procedure as specified in § 89.406. (3) Read and record the general test data as... (c)(5)(i) through (iii) of this section. (6) Read and record all pre-test data specified in § 89.405... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine dynamometer test run. 89.407...

  14. [Supplementary device for a dynamometer to evaluate and register muscular endurance indices].

    PubMed

    Timoshenko, D A; Bokser, O Ia

    1986-01-01

    In practice of psychophysiologic research muscular endurance index is used for estimation of CNS function. Muscular endurance index is defined as relative time needed for maintaining the preset muscular effort. The described device widens the possibilities of a digital dynamometer for automatic estimation and recording of muscular endurance index in real time.

  15. NREL-Prime Next-Generation Drivetrain Dynamometer Test Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keller, Jonathan; Erdman, Bill; Blodgett, Douglas

    2016-08-01

    Advances in wind turbine drivetrain technologies are necessary to improve reliability and reduce the cost of energy for land-based and offshore wind turbines. The NREL-Prime Next-Generation Drivetrain team developed a geared, medium-speed drivetrain that is lighter, more reliable and more efficient than existing designs. One of the objectives of Phase II of the project was to complete the detailed design, fabrication, and dynamometer testing of a 750 kilowatt (kW) drivetrain that includes the key gearbox innovations designed by Romax Technology and power converter innovations designed by DNV Kema Renewables. The purpose of this document is to summarize these tests completedmore » in NREL's National Wind Technology Center 2.5 megawatt (MW) dynamometer.« less

  16. An instrumented object for hand exercise and assessment using a pneumatic pressure sensor

    NASA Astrophysics Data System (ADS)

    Mohan, A.; Tharion, G.; Kumar, R. K.; Devasahayam, S. R.

    2018-05-01

    Measurement of grip force is important for both exercise training and assessment of the hand during physical rehabilitation. The standard method uses a grip dynamometer which measures the force between the fingers and opposing thumb. The primary limitation of the grip dynamometer is the restriction of measurement to cylindrical grasps. Any deformation of the hand due to muscular or skeletal disease makes the grip dynamometer difficult or impossible to use. An alternative to the grip dynamometer is a sealed pneumatic object that can be gripped by the hand. Measurement of the internal pressure in the object can be related to the grip force. In this paper, we analyze such a pneumatic pressure sensing object for hand grip assessment and also describe an easy fabrication of the grip sensor. The instrumented object presented in this paper is designed to assess both the maximal voluntary grip forces and continuous grip force to monitor control of hand function during exercise under instruction from a therapist. Potential uses of such a pneumatic pressure sensing object for hand grip are in physical rehabilitation of patients following paralysing illnesses like stroke and spinal cord injury.

  17. Development of a portable anchored dynamometer for collection of maximal voluntary isometric contractions in biomechanics research on dancers.

    PubMed

    Krasnow, Donna; Ambegaonkar, Jatin P; Stecyk, Shane; Wilmerding, M Virginia; Wyon, Matthew; Koutedakis, Yiannis

    2011-12-01

    Surface electromyography (sEMG) has been used in dance medicine research since the 1970s, but normalization procedures are not consistently employed in the field. The purpose of this project was to develop a portable anchored dynamometer (PAD) specifically for dance-related research. Due to the limited studies in the dance research literature using normalization procedures for sEMG data, a review of the procedures used in the exercise science literature was conducted. A portable anchored dynamometer was then developed and tested with dancers, using methods validated in previous literature. We collected sEMG maximum voluntary isometric contractions (MVIC, mV) from 10 female dancers (mean age 31.0 ± 15 yrs, mean height 163 ± 7.6 cm, mean weight 57.6 ± 6.9 kg, and 17.0 ± 13.9 yrs of training in ballet and/or modern dance) over three trials (5 sec each) for eight muscles bilaterally (quadriceps, tibialis anterior, abductor hallucis, gastrocnemius, hamstrings, gluteus maximus, erector spinae, and rectus abdominus). Consistency of data and feedback from dancers suggest that this dance-specific portable anchored dynamometer is effective for future sEMG studies in dance research.

  18. Cross-point-type spin-transfer-torque magnetoresistive random access memory cell with multi-pillar vertical body channel MOSFET

    NASA Astrophysics Data System (ADS)

    Sasaki, Taro; Endoh, Tetsuo

    2018-04-01

    In this paper, from the viewpoint of cell size and sensing margin, the impact of a novel cross-point-type one transistor and one magnetic tunnel junction (1T–1MTJ) spin-transfer-torque magnetoresistive random access memory (STT-MRAM) cell with a multi-pillar vertical body channel (BC) MOSFET is shown for high density and wide sensing margin STT-MRAM, with a 10 ns writing period and 1.2 V V DD. For that purpose, all combinations of n/p-type MOSFETs and bottom/top-pin MTJs are compared, where the diameter of MTJ (D MTJ) is scaled down from 55 to 15 nm and the tunnel magnetoresistance (TMR) ratio is increased from 100 to 200%. The results show that, benefiting from the proposed STT-MRAM cell with no back bias effect, the MTJ with a high TMR ratio (200%) can be used in the design of smaller STT-MRAM cells (over 72.6% cell size reduction), which is a difficult task for conventional planar MOSFET based design.

  19. The electrodynamometric balance of the small wind tunnel of the French Service of Aeronautical Research

    NASA Technical Reports Server (NTRS)

    Rebuffet, P

    1930-01-01

    This investigation shows the attempt to improve the electrodynamomoter designed by Mr. Villey. The force to be measured acts on a flexible steel plate which is placed in front of a fixed plate. The deformation varies the original thickness of the layer of air between the two plates, thus causing a more rapid variation in the coefficient of electrostatic attraction of the two plates than in the capacity of the condenser formed by the dynamometer. The measurements are made by a differential method. The capacity of the test dynamometer is compared with that of a similar instrument of constant capacity, this comparison being made by means of an electrometer. Diagrams are shown of the dynamometer, the electrometer, and the electrical connections.

  20. Aggregate Mesenchymal Stem Cell Delivery Ameliorates the Regenerative Niche for Muscle Repair.

    PubMed

    Ruehle, Marissa A; Stevens, Hazel Y; Beedle, Aaron M; Guldberg, Robert E; Call, Jarrod A

    2018-05-18

    Duchenne muscular dystrophy (DMD) is a severe muscle wasting disease due to the absence of the dystrophin protein from the muscle cell membrane which renders the muscle susceptible to continuous damage. In DMD patients, muscle weakness, together with cycles of degeneration/regeneration and replacement with non-contractile tissue, limit mobility and lifespan. Since the loss of dystrophin result in loss of polarity and a reduction in the number of self-renewing satellite cells, it is postulated that these patients could achieve an improved quality of life if delivered cells could restore satellite cell function. In this study we used both an established myotoxic injury model in wildtype (WT) mice and mdx mice alone (spontaneous muscle damage). Single (SC) and aggregated (AGG) mesenchymal stem cells (MSCs) were injected into the gastrocnemius muscles 4 hours after injury (WT mice). The recovery of peak isometric torque was longitudinally assessed over 5 weeks, with earlier takedowns for histological assessment of healing (fiber cross section area and central nucleation) and MSC retention. AGG-treated WT mice had significantly greater torque recovery at day 14 than SC or saline-treated mice and a greater CSA at day 10, compared to SC/saline. AGG-treated mdx mice had a greater peak isometric torque compared to SC/saline. In vitro immunomodulatory factor secretion of AGG-MSCs was higher than SC-MSCs for all tested growth factors with the largest difference observed in hepatocyte growth factor (HGF). Future studies are necessary to pair immunomodulatory factor secretion with functional attributes, to better predict the potential therapeutic value of MSC treatment modalities. This article is protected by copyright. All rights reserved.

  1. Periplasmal Physics: The Rotational Dynamics of Spirochetal Flagella

    NASA Astrophysics Data System (ADS)

    Huber, Greg

    2012-02-01

    Spirochetes are distinguished by the location of their flagella, which reside within the periplasm: the tiny space between the bacterial cell wall and the outer membrane. In Borrelia burgdorferi/ (the causative agent of Lyme Disease), rotation of the flagella leads to cellular undulations that drive swimming. Exactly how these shape changes arise due to the forces and torques acting between the flagella and the cell body is unknown. By applying low-Reynolds number hydrodynamic theory to the motion of an elastic flagellum rotating in the periplasm, we show that the flagella are most likely separated from the bacterial cell wall by a lubricating layer of fluid. We obtain analytical solutions for the force and torque on the rotating flagellum through lubrication analysis, as well as through scaling analysis, and find results are in close agreement numerical simulations. (Joint work with J. Yang and C.W. Wolgemuth.)

  2. Biophysical Characterization of a Thermoalkaliphilic Molecular Motor with a High Stepping Torque Gives Insight into Evolutionary ATP Synthase Adaptation*

    PubMed Central

    McMillan, Duncan G. G.; Watanabe, Rikiya; Ueno, Hiroshi; Cook, Gregory M.; Noji, Hiroyuki

    2016-01-01

    F1F0 ATP synthases are bidirectional molecular motors that translocate protons across the cell membrane by either synthesizing or hydrolyzing ATP. Alkaliphile ATP synthases are highly adapted, performing oxidative phosphorylation at high pH against an inverted pH gradient (acidin/alkalineout). Unlike mesophilic ATP synthases, alkaliphilic enzymes have tightly regulated ATP hydrolysis activity, which can be relieved in the presence of lauryldimethylamine oxide. Here, we characterized the rotary dynamics of the Caldalkalibacillus thermarum TA2.A1 F1 ATPase (TA2F1) with two forms of single molecule analysis, a magnetic bead duplex and a gold nanoparticle. TA2F1 rotated in a counterclockwise direction in both systems, adhering to Michaelis-Menten kinetics with a maximum rotation rate (Vmax) of 112.4 revolutions/s. TA2F1 displayed 120° unitary steps coupled with ATP hydrolysis. Torque measurements revealed the highest torque (52.4 piconewtons) derived from an F1 molecule using fluctuation theorem. The implications of high torque in terms of extreme environment adaptation are discussed. PMID:27624936

  3. Magnetic tweezers: micromanipulation and force measurement at the molecular level.

    PubMed Central

    Gosse, Charlie; Croquette, Vincent

    2002-01-01

    Cantilevers and optical tweezers are widely used for micromanipulating cells or biomolecules for measuring their mechanical properties. However, they do not allow easy rotary motion and can sometimes damage the handled material. We present here a system of magnetic tweezers that overcomes those drawbacks while retaining most of the previous dynamometers properties. Electromagnets are coupled to a microscope-based particle tracking system through a digital feedback loop. Magnetic beads are first trapped in a potential well of stiffness approximately 10(-7) N/m. Thus, they can be manipulated in three dimensions at a speed of approximately 10 microm/s and rotated along the optical axis at a frequency of 10 Hz. In addition, our apparatus can work as a dynamometer relying on either usual calibration against the viscous drag or complete calibration using Brownian fluctuations. By stretching a DNA molecule between a magnetic particle and a glass surface, we applied and measured vertical forces ranging from 50 fN to 20 pN. Similarly, nearly horizontal forces up to 5 pN were obtained. From those experiments, we conclude that magnetic tweezers represent a low-cost and biocompatible setup that could become a suitable alternative to the other available micromanipulators. PMID:12023254

  4. Mechanical correction of dynamometer moment for the effects of segment motion during isometric knee-extension tests

    PubMed Central

    Baltzopoulos, Vasilios; Richards, Paula J.; Maganaris, Constantinos N.

    2011-01-01

    The purpose of this study was to determine the effect of dynamometer and joint axis misalignment on measured isometric knee-extension moments using inverse dynamics based on the actual joint kinematic information derived from the real-time X-ray video and to compare the errors when the moments were calculated using measurements from external anatomical surface markers or obtained from the isokinetic dynamometer. Six healthy males participated in this study. They performed isometric contractions at 90° and 20° of knee flexion, gradually increasing to maximum effort. For the calculation of the actual knee-joint moment and the joint moment relative to the knee-joint center, determined using the external marker, two free body diagrams were used of the Cybex arm and the lower leg segment system. In the first free body diagram, the mean center of the circular profiles of the femoral epicondyles was used as the knee-joint center, whereas in the second diagram, the joint center was assumed to coincide with the external marker. Then, the calculated knee-joint moments were compared with those measured by the dynamometer. The results indicate that 1) the actual knee-joint moment was different from the dynamometer recorded moment (difference ranged between 1.9% and 4.3%) and the moment calculated using the skin marker (difference ranged between 2.5% and 3%), and 2) during isometric knee extension, the internal knee angle changed significantly from rest to the maximum contraction state by about 19°. Therefore, these differences cannot be neglected if the moment–knee-joint angle relationship or the muscle mechanical properties, such as length-tension relationship, need to be determined. PMID:21474701

  5. Longitudinal assessment of grip strength using bulb dynamometer in Duchenne Muscular Dystrophy

    PubMed Central

    Pizzato, Tatiana M.; Baptista, Cyntia R. J. A.; Souza, Mariana A.; Benedicto, Michelle M. B.; Martinez, Edson Z.; Mattiello-Sverzut, Ana C.

    2014-01-01

    BACKGROUND: Grip strength is used to infer functional status in several pathological conditions, and the hand dynamometer has been used to estimate performance in other areas. However, this relationship is controversial in neuromuscular diseases and studies with the bulb dynamometer comparing healthy children and children with Duchenne Muscular Dystrophy (DMD) are limited. OBJECTIVE: The evolution of grip strength and the magnitude of weakness were examined in boys with DMD compared to healthy boys. The functional data of the DMD boys were correlated with grip strength. METHOD: Grip strength was recorded in 18 ambulant boys with DMD (Duchenne Group, DG) aged 4 to 13 years (mean 7.4±2.1) and 150 healthy volunteers (Control Group, CG) age-matched using a bulb dynamometer (North Coast- NC70154). The follow-up of the DG was 6 to 33 months (3-12 sessions), and functional performance was verified using the Vignos scale. RESULTS: There was no difference between grip strength obtained by the dominant and non-dominant side for both groups. Grip strength increased in the CG with chronological age while the DG remained stable or decreased. The comparison between groups showed significant difference in grip strength, with CG values higher than DG values (confidence interval of 95%). In summary, there was an increment in the differences between the groups with increasing age. Participants with 24 months or more of follow-up showed a progression of weakness as well as maintained Vignos scores. CONCLUSIONS: The amplitude of weakness increased with age in the DG. The bulb dynamometer detected the progression of muscular weakness. Functional performance remained virtually unchanged in spite of the increase in weakness. PMID:25003277

  6. Spin-orbit torque magnetization switching of a three-terminal perpendicular magnetic tunnel junction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cubukcu, Murat; Boulle, Olivier; Drouard, Marc

    2014-01-27

    We report on the current-induced magnetization switching of a three-terminal perpendicular magnetic tunnel junction by spin-orbit torque and its read-out using the tunnelling magnetoresistance (TMR) effect. The device is composed of a perpendicular Ta/FeCoB/MgO/FeCoB stack on top of a Ta current line. The magnetization of the bottom FeCoB layer can be switched reproducibly by the injection of current pulses with density 5 × 10{sup 11} A/m{sup 2} in the Ta layer in the presence of an in-plane bias magnetic field, leading to the full-scale change of the TMR signal. Our work demonstrates the proof of concept of a perpendicular spin-orbit torque magnetic memorymore » cell.« less

  7. Single ball bearing lubricant and material evaluator

    NASA Technical Reports Server (NTRS)

    Hall, Philip B. (Inventor); Novak, Howard L. (Inventor)

    2005-01-01

    A test apparatus provides an applied load to a monoball through a trolley which moves along a loading axis. While applying the load to the monoball, the torque meter is in communication with the spherical monoball, and a load cell senses the application of applied force to the monoball. Meanwhile, a rotary actuary imports rotary oscillating motion to the monoball which is sensed by a position sensor and a torque meter. Accordingly, a processor can determine the coefficient of friction in substantially real time along with a cycles per second rate.

  8. Single Ball Bearing Lubricant and Material Evaluator

    NASA Technical Reports Server (NTRS)

    Hall, Philip B. (Inventor); Novak, Howard L. (Inventor)

    2005-01-01

    A test apparatus provides an applied load to a monoball through a trolley which moves along a loading axis. While applying the load to the monoball, the torque meter is in communication with the spherical monoball, and a load cell senses the application of applied force to the monoball. Meanwhile, a rotary actuary imports rotary oscillating motion to the monoball which is sensed by a position sensor and a torque meter. Accordingly, a processor can determine the coefficient of friction in substantially real time along with a cycles per second rate.

  9. Motor impairments related to brain injury timing in early hemiparesis. Part II: abnormal upper extremity joint torque synergies.

    PubMed

    Sukal-Moulton, Theresa; Krosschell, Kristin J; Gaebler-Spira, Deborah J; Dewald, Julius P A

    2014-01-01

    Extensive neuromotor development occurs early in human life, and the timing of brain injury may affect the resulting motor impairment. In Part I of this series, it was demonstrated that the distribution of weakness in the upper extremity depended on the timing of brain injury in individuals with childhood-onset hemiparesis. The goal of this study was to characterize how timing of brain injury affects joint torque synergies, or losses of independent joint control. Twenty-four individuals with hemiparesis were divided into 3 groups based on the timing of their injury: before birth (PRE-natal, n = 8), around the time of birth (PERI-natal, n = 8), and after 6 months of age (POST-natal, n = 8). Individuals with hemiparesis and 8 typically developing peers participated in maximal isometric shoulder, elbow, wrist, and finger torque generation tasks while their efforts were recorded by a multiple degree-of-freedom load cell. Motor output in 4 joints of the upper extremity was concurrently measured during 8 primary torque generation tasks to quantify joint torque synergies. There were a number of significant coupling patterns identified in individuals with hemiparesis that differed from the typically developing group. POST-natal differences were most noted in the coupling of shoulder abductors with elbow, wrist, and finger flexors, while the PRE-natal group demonstrated significant distal joint coupling with elbow flexion. The torque synergies measured provide indirect evidence for the use of bulbospinal pathways in the POST-natal group, while those with earlier injury may use relatively preserved ipsilateral corticospinal motor pathways.

  10. Micromechanical apparatus for measurement of forces

    DOEpatents

    Tanner, Danelle Mary; Allen, James Joe

    2004-05-25

    A new class of micromechanical dynamometers has been disclosed which are particularly suited to fabrication in parallel with other microelectromechanical apparatus. Forces in the microNewton regime and below can be measured with such dynamometers which are based on a high-compliance deflection element (e.g. a ring or annulus) suspended above a substrate for deflection by an applied force, and one or more distance scales for optically measuring the deflection.

  11. Intra- and Inter-Rater Reliability of the Rate of Force Development of Hip Abductor Muscles Measured by Hand-Held Dynamometer

    ERIC Educational Resources Information Center

    Takeda, Kazuya; Tanabe, Shigeo; Koyama, Soichiro; Nagai, Tomoko; Sakurai, Hiroaki; Kanada, Yoshikiyo; Shomoto, Koji

    2018-01-01

    The aim of this study was to clarify the intra- and inter-rater reliability of the rate of force development in hip abductor muscle force measurements using a hand-held dynamometer. Thirty healthy adults were separately assessed by two independent raters on two separate days. Rate of force development was calculated from the slope of the…

  12. Development of an Industry Dynamometer/Spin Test Facility--Equipment Only: Cooperative Research and Development Final Report, CRADA Number CRD-05-164

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDade, Mark

    2016-12-01

    The Department of Energy/National Renewable Energy Laboratory (DOE/NREL) owns and operates a megawatt-scale dynamometer used for testing wind turbine drive trains up to 1.5 megawatt (MW) in rated capacity. At this time, this unit is the only unit of its type in the United States, available for use by the American Wind Industry. Currently this dynamometer is heavily backlogged and unavailable to provide testing needed by various wind industry members. DOE/NREL is in possession of two critical pieces of equipment that may be used to develop an alternative Dynamometer facility, but does not have the funds or other resources necessarymore » to develop such a facility. The Participant possesses complimentary facilities and infrastructure that when combined with the NREL equipment can create such a test facility. The Participant is also committed to expending funds to develop and operate such a facility to the subsequent benefit of the Wind Industry and DOE Wind Energy program. In exchange for DOE/NREL providing the critical equipment, the Participant will grant DOE/NREL a minimum of 90 days of testing time per year in the new facility while incurring no facilities fees.« less

  13. Isokinetic and isometric strength in osteoarthrosis of the knee. A comparative study with healthy women.

    PubMed

    Tan, J; Balci, N; Sepici, V; Gener, F A

    1995-01-01

    Dynamic stability of the knee joint depends on the appropriate strength ratio of quadriceps and hamstring muscles. The purpose of this investigation was to determine the maximum peak torque (MPT) and MPT ratios of hamstrings to quadriceps (H/Q) muscles in patients with knee osteoarthritis (OA). Two groups of patients were included in the study. The first group consisted of 30 patients (Group A) with the clinical and radiologic findings of knee OA. The second group consisted of 30 patients (Group B) exhibiting knee joint pain without roentgenologic findings of knee OA. The findings of two patient groups were compared with each other and also with 30 healthy subjects (Group C). Isokinetic (at 60 degrees/s and at 180 degrees/s) and isometric (at 30 degrees and at 60 degrees of knee flexion) tests were performed by the rate-limiting isokinetic dynamometer system. Isokinetic and isometric MPT loss of knee flexors and extensors was found in both patient groups with respect to controls, but MPT ratios of H/Q muscles did not show a statistically significant difference compared with the control group. This may be related to the equal strength loss of knee flexors and knee extensors in patients with knee OA. It is concluded that strengthening exercises of hamstring muscles is as important as quadriceps strengthening in rehabilitation of knee OA.

  14. The increase in physical performance and gain in lean and fat mass occur in prepubertal children independent of mode of school transportation. One year data from the prospective controlled Pediatric Osteoporosis Prevention (POP) Study

    PubMed Central

    2009-01-01

    Background The aim of this 12-month study in pre-pubertal children was to evaluate the effect of school transportation on gain in lean and fat mass, muscle strength and physical performance. Methods Ninety-seven girls and 133 boys aged 7-9 years from the Malmö Pediatric Osteoporosis Prevention Study were included. Regional lean and fat mass were assessed by dual energy X-ray absorptiometry, isokinetic peak torque of knee extensors and flexors by a computerised dynamometer and physical performance by vertical jump height. Level of physical activity was assessed by accelerometers. The 12-month changes in children who walked or cycled to school were compared with changes in those who travelled by bus or car. Results There were no differences in baseline or annual changes in lean or fat mass gain, muscle strength or physical performance between the two groups. All children reached the internationally recommended level of 60 minutes per day of moderate or high physical activity by accelerometers. Conclusion The choice of school transportation in pre-pubertal children seems not to influence the gain in lean and fat mass, muscle strength or functional ability, probably as the everyday physical activity is so high that the mode of school transportation contributes little to the total level of activity.

  15. A low-fat yoghurt supplemented with a rooster comb extract on muscle joint function in adults with mild knee pain: a randomized, double blind, parallel, placebo-controlled, clinical trial of efficacy.

    PubMed

    Solà, Rosa; Valls, Rosa-Maria; Martorell, Isabel; Giralt, Montserrat; Pedret, Anna; Taltavull, Núria; Romeu, Marta; Rodríguez, Àurea; Moriña, David; Lopez de Frutos, Victor; Montero, Manuel; Casajuana, Maria-Carmen; Pérez, Laura; Faba, Jenny; Bernal, Gloria; Astilleros, Anna; González, Roser; Puiggrós, Francesc; Arola, Lluís; Chetrit, Carlos; Martinez-Puig, Daniel

    2015-11-01

    Preliminary results suggested that oral-administration of rooster comb extract (RCE) rich in hyaluronic acid (HA) was associated with improved muscle strength. Following these promising results, the objective of the present study was to evaluate the effect of low-fat yoghurt supplemented with RCE rich in HA on muscle function in adults with mild knee pain; a symptom of early osteoarthritis. Participants (n = 40) received low-fat yoghurt (125 mL d(-1)) supplemented with 80 mg d(-1) of RCE and the placebo group (n = 40) consumed the same yoghurt without the RCE, in a randomized, controlled, double-blind, parallel trial over 12 weeks. Using an isokinetic dynamometer (Biodex System 4), RCE consumption, compared to control, increased the affected knee peak torque, total work and mean power at 180° s(-1), at least 11% in men (p < 0.05) with no differences in women. No dietary differences were noted. These results suggest that long-term consumption of low-fat yoghurt supplemented with RCE could be a dietary tool to improve muscle strength in men, associated with possible clinical significance. However, further studies are needed to elucidate reasons for these sex difference responses observed, and may provide further insight into muscle function.

  16. Beta-alanine supplementation improves isometric, but not isotonic or isokinetic strength endurance in recreationally strength-trained young men.

    PubMed

    Bassinello, Diogo; de Salles Painelli, Vitor; Dolan, Eimear; Lixandrão, Manoel; Cajueiro, Monique; de Capitani, Mariana; Saunders, Bryan; Sale, Craig; Artioli, Guilherme G; Gualano, Bruno; Roschel, Hamilton

    2018-06-15

    β-Alanine (BA) supplementation may be ergogenic during high-intensity exercise, primarily due to the buffering of hydrogen cations, although the effects of beta-alanine supplementation on strength endurance are equivocal. The aim of the study was to determine the effects of 4 weeks of beta-alanine supplementation on skeletal muscle endurance using a battery of performance tests. This study employed a parallel group, repeated measures, randomised, double-blinded and placebo-controlled design. Twenty recreationally strength-trained healthy males completed tests of isotonic strength endurance (repeated bench and leg press), along with tests of isometric and isokinetic endurance conducted using an isokinetic dynamometer. Tests were performed before and after a 4 week intervention, comprising an intake of 6.4 g day -1 of BA (n = 9) or placebo (maltodextrin, n = 11). Time-to-exhaustion during the isometric endurance test improved by ~ 17% in the BA group (p < 0.01), while PL remained unchanged. No significant within-group differences (p > 0.1) were shown for any of the performance variables in the isokinetic test (peak torque, fatigue index, total work) nor for the total number of repetitions performed in the isotonic endurance tests (leg or bench press). Four weeks of BA supplementation (6.4 g day -1 ) improved isometric, but not isokinetic or isotonic endurance performance.

  17. Multiple risk factors related to familial predisposition to anterior cruciate ligament injury: fraternal twin sisters with anterior cruciate ligament ruptures

    PubMed Central

    Hewett, T E; Lynch, T R; Myer, G D; Ford, K R; Gwin, R C; Heidt, R S

    2014-01-01

    Objective A multifactorial combination of predictors may increase anterior cruciate ligament (ACL) injury risk in athletes. The objective of this twin study was to examine these risk factors to identify commonalities in risk factors that predisposed female fraternal twins to ACL injury. Methods Female twins in high-risk sports were prospectively measured prior to an injury for neuromuscular control using three-dimensional motion analysis during landing, hamstrings and quadriceps muscular strength on a dynamometer and joint laxity using a modified Beighton–Horan index and a Compu-KT arthrometer. Intraoperative measures of femoral intercondylar notch width were recorded during ACL reconstruction. Results Abduction angles were increased at one knee in both of the twin sister athletes relative to uninjured controls at initial contact and at maximum displacement during landing. The twin female athletes that went on to ACL injury also demonstrated decreased peak knee flexion motion at both knees than uninjured females during landing. The twin athletes also had increased joint laxity and decreased hamstrings to quadriceps (H/Q) torque ratios compared to controls. Femoral intercondylar notch widths were also below the control mean in the twin siblings. Conclusions Prescreened mature female twins that subsequently experienced ACL injury demonstrated multiple potential risk factors including: increased knee abduction angles, decreased knee flexion angles, increased general joint laxity, decreased H/Q ratios and femoral intercondylar notch width. PMID:19158132

  18. Reliability of a device for the knee and ankle isometric and isokinetic strength testing in older adults

    PubMed Central

    Bergamin, Marco; Gobbo, Stefano; Bullo, Valentina; Vendramin, Barbara; Duregon, Federica; Frizziero, Antonio; Di Blasio, Andrea; Cugusi, Lucia; Zaccaria, Marco; Ermolao, Andrea

    2017-01-01

    Summary Background Lower extremity muscle mass, strength, power, and physical performance are critical determinants of independent functioning in later life. Isokinetic dynamometers are becoming very common in assessing different features of muscle strength, in both research and clinical practice; however, reliability studies are still needed to support the extended use of those devices. Objective The purpose of this study is to assess the test-retest reliability of knee and ankle isokinetic and isometric strength testing protocols in a sample of older healthy subjects, using a new and untested isokinetic multi-joint evaluation system. Methods Sixteen male and fourteen female older adults (mean age 65.2 ± 4.6 years) were assessed in two testing sessions. Each participant performed a randomized testing procedure that includes different isometric and isokinetic tests for knee and ankle joints. Results All participants concluded the trial safety and no subject reported any discomfort throughout the overall assessment. Coefficients of correlation between measures were calculated showing moderate to strong effects among all test-retest assessments and paired-sample t test showed only one significant difference (p<0.05) in the maximal isokinetic bilateral knee flexion torque. Conclusions The multi-joint evaluation system for the assessment of knee and ankle isokinetic and isometric strength provided reliable test-retest measures in healthy older adults. Level of evidence Ib. PMID:29264344

  19. Nonparetic Knee Extensor Strength Is the Determinant of Exercise Capacity of Community-Dwelling Stroke Survivors

    PubMed Central

    Wang, Wei-Te; Huang, Ling-Tzu; Chou, Ya-Hui; Wei, Ta-Sen; Lin, Chung-Che

    2014-01-01

    Objective. To investigate the relationship among walking speed, exercise capacity, and leg strength in community dwelling stroke subjects and to evaluate which one was the leading determinant factor of them. Design. This is a descriptive, cross-sectional study. Thirty-five chronic stroke patients who were able to walk independently in their community were enrolled. Walking speed was evaluated by using the 12-meter walking test. A maximal exercise test was used to determine the stroke subjects' exercise capacity. Knee extensor strength, measured as isokinetic torque, was assessed by isokinetic dynamometer. Results. The main walking speed of our subjects was 0.52 m/s. Peak oxygen uptake (VO2 peak) was 1.21 ± 0.43 L/min. Knee extensor strength, no matter whether paretic or nonparetic side, was significantly correlated to 12-meter walking speed and exercise capacity. Linear regression also showed the strength of the affected knee extensor was the determinant of walking speed and that of the nonparetic knee extensor was the determinant of exercise capacity in community dwelling stroke subjects. Conclusions. Walking speed and peak oxygen uptake were markedly decreased after stroke. Knee extensor strength of nonparetic leg was the most important determinant of exercise capacity of the community-dwelling stroke subjects. Knee extensor strengthening should be emphasized to help stroke patient to achieve optimal community living. PMID:25197712

  20. Isokinetic Testing in Evaluation Rehabilitation Outcome After ACL Reconstruction

    PubMed Central

    Cvjetkovic, Dragana Dragicevic; Bijeljac, Sinisa; Palija, Stanislav; Talic, Goran; Radulovic, Tatjana Nozica; Kosanovic, Milkica Glogovac; Manojlovic, Slavko

    2015-01-01

    Introduction: Numerous rehab protocols have been used in rehabilitation after ACL reconstruction. Isokinetic testing is an objective way to evaluate dynamic stability of the knee joint that estimates the quality of rehabilitation outcome after ACL reconstruction. Our investigation goal was to show importance of isokinetic testing in evaluation thigh muscle strength in patients which underwent ACL reconstruction and rehabilitation protocol. Subjects and methods: In prospective study, we evaluated 40 subjects which were divided into two groups. Experimental group consisted of 20 recreational males which underwent ACL reconstruction with hamstring tendon and rehabilitation protocol 6 months before isokinetic testing. Control group (20 subjects) consisted of healthy recreational males. In all subjects knee muscle testing was performed on a Biodex System 4 Pro isokinetic dynamo-meter et velocities of 60°/s and 180°/s. We followed average peak torque to body weight (PT/BW) and classic H/Q ratio. In statistical analysis Student’s T test was used. Results: There were statistically significant differences between groups in all evaluated parameters except of the mean value of PT/BW of the quadriceps et velocity of 60°/s (p>0.05). Conclusion: Isokinetic testing of dynamic stabilizers of the knee is need in diagnostic and treatment thigh muscle imbalance. We believe that isokinetic testing is an objective parameter for return to sport activities after ACL reconstruction. PMID:25870471

  1. Nonparetic knee extensor strength is the determinant of exercise capacity of community-dwelling stroke survivors.

    PubMed

    Wang, Wei-Te; Huang, Ling-Tzu; Chou, Ya-Hui; Wei, Ta-Sen; Lin, Chung-Che

    2014-01-01

    To investigate the relationship among walking speed, exercise capacity, and leg strength in community dwelling stroke subjects and to evaluate which one was the leading determinant factor of them. This is a descriptive, cross-sectional study. Thirty-five chronic stroke patients who were able to walk independently in their community were enrolled. Walking speed was evaluated by using the 12-meter walking test. A maximal exercise test was used to determine the stroke subjects' exercise capacity. Knee extensor strength, measured as isokinetic torque, was assessed by isokinetic dynamometer. The main walking speed of our subjects was 0.52 m/s. Peak oxygen uptake (VO₂ peak) was 1.21 ± 0.43 L/min. Knee extensor strength, no matter whether paretic or nonparetic side, was significantly correlated to 12-meter walking speed and exercise capacity. Linear regression also showed the strength of the affected knee extensor was the determinant of walking speed and that of the nonparetic knee extensor was the determinant of exercise capacity in community dwelling stroke subjects. Walking speed and peak oxygen uptake were markedly decreased after stroke. Knee extensor strength of nonparetic leg was the most important determinant of exercise capacity of the community-dwelling stroke subjects. Knee extensor strengthening should be emphasized to help stroke patient to achieve optimal community living.

  2. Volvo Penta 4.3 GL E15 Emissions and Durability Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zoubul, G.; Cahoon, M.; Kolb, R.

    2011-10-01

    A new Volvo Penta carbureted 4.3 GL engine underwent emissions and dynamometer durability testing from break-in to expected end of life using an accelerated ICOMIA marine emissions cycle and E15 fuel. Only ethanol content was controlled. All aging used splash-blended E15 fuel. Exhaust emissions, exhaust gas temperature, torque, power, barometric pressure, air temperature, and fuel flow were measured at five intervals using site-blended E15 aging fuel and certification fuel (E0). The durability test cycle showed no noticeable impact on mechanical durability or engine power. Emissions performance degraded beyond the certification limit for this engine family, mostly occurring by 28% ofmore » expected life. Such degradation is inconsistent with prior experience. Comparisons showed that E15 resulted in lower CO and HC, but increased NOX, as expected for non-feedback-controlled carbureted engines with increased oxygen in the fuel. Fuel consumption also increased with E15 compared with E0. Throughout testing, poor starting characteristics were exhibited on E15 fuel for hot re-start and cold-start. Cranking time to start and smooth idle was roughly doubled compared with typical E0 operation. The carburetor was factory-set for lean operation to ensure emissions compliance. Test protocols did not include carburetor adjustment to account for increased oxygen in the E15 fuel.« less

  3. Effects of equal-volume resistance training with different training frequencies in muscle size and strength in trained men

    PubMed Central

    Fisher, James; Steele, James; Campos, Mario H.; Silva, Marcelo H.; Paoli, Antonio; Giessing, Jurgen; Bottaro, Martim

    2018-01-01

    Background The objective of the present study was to compare the effects of equal-volume resistance training (RT) performed with different training frequencies on muscle size and strength in trained young men. Methods Sixteen men with at least one year of RT experience were divided into two groups, G1 and G2, that trained each muscle group once and twice a week, respectively, for 10 weeks. Elbow flexor muscle thickness (MT) was measured using a B-Mode ultrasound and concentric peak torque of elbow extensors and flexors were assessed by an isokinetic dynamometer. Results ANOVA did not reveal group by time interactions for any variable, indicating no difference between groups for the changes in MT or PT of elbow flexors and extensors. Notwithstanding, MT of elbow flexors increased significantly (3.1%, P < 0.05) only in G1. PT of elbow flexors and extensors did not increase significantly for any group. Discussion The present study suggest that there were no differences in the results promoted by equal-volume resistance training performed once or twice a week on upper body muscle strength in trained men. Only the group performing one session per week significantly increased the MT of their elbow flexors. However, with either once or twice a week training, adaptations appear largely minimal in previously trained males.

  4. Effects of equal-volume resistance training with different training frequencies in muscle size and strength in trained men.

    PubMed

    Gentil, Paulo; Fisher, James; Steele, James; Campos, Mario H; Silva, Marcelo H; Paoli, Antonio; Giessing, Jurgen; Bottaro, Martim

    2018-01-01

    The objective of the present study was to compare the effects of equal-volume resistance training (RT) performed with different training frequencies on muscle size and strength in trained young men. Sixteen men with at least one year of RT experience were divided into two groups, G1 and G2, that trained each muscle group once and twice a week, respectively, for 10 weeks. Elbow flexor muscle thickness (MT) was measured using a B-Mode ultrasound and concentric peak torque of elbow extensors and flexors were assessed by an isokinetic dynamometer. ANOVA did not reveal group by time interactions for any variable, indicating no difference between groups for the changes in MT or PT of elbow flexors and extensors. Notwithstanding, MT of elbow flexors increased significantly (3.1%, P  < 0.05) only in G1. PT of elbow flexors and extensors did not increase significantly for any group. The present study suggest that there were no differences in the results promoted by equal-volume resistance training performed once or twice a week on upper body muscle strength in trained men. Only the group performing one session per week significantly increased the MT of their elbow flexors. However, with either once or twice a week training, adaptations appear largely minimal in previously trained males.

  5. An isoenergetic high-protein, moderate-fat diet does not compromise strength and fatigue during resistance exercise in women.

    PubMed

    Dipla, Konstantina; Makri, Maria; Zafeiridis, Andreas; Soulas, Dimitrios; Tsalouhidou, Sofia; Mougios, Vassilis; Kellis, Spyros

    2008-08-01

    Resistance exercise is recommended to individuals following high-protein diets in order to augment changes in body composition. However, alterations in macronutrient composition may compromise physical performance. The present study investigated the effects of an isoenergetic high-protein diet on upper and lower limb strength and fatigue during high-intensity resistance exercise. Ten recreationally active women, aged 25-40 years, followed a control diet (55, 15 and 30 % of energy from carbohydrate, protein and fat, respectively) and a high-protein diet (respective values, 30, 40 and 30) for 7 d each in a random counterbalanced design. Each participant underwent strength testing of upper limb (isometric handgrip strength and endurance) and lower limb (four sets of sixteen maximal knee flexions and extensions on an isokinetic dynamometer) before and after applying each diet. Body weight, body fat and RER were significantly reduced following the high-protein diet (P < 0.05). No differences were found between diets in any of the strength performance parameters (handgrip strength, handgrip endurance, peak torque, total work and fatigue) or the responses of heart rate, systolic and diastolic arterial pressure, blood lactate and blood glucose to exercise. Women on a short-term isoenergetic high-protein, moderate-fat diet maintained muscular strength and endurance of upper and lower limbs during high-intensity resistance exercise without experiencing fatigue earlier compared with a control diet.

  6. Torque limit of PM motors for field-weakening region operation

    DOEpatents

    Royak, Semyon [Beachwood, OH; Harbaugh, Mark M [Richfield, OH

    2012-02-14

    The invention includes a motor controller and technique for controlling a permanent magnet motor. In accordance with one aspect of the present technique, a permanent magnet motor is controlled by receiving a torque command, determining a physical torque limit based on a stator frequency, determining a theoretical torque limit based on a maximum available voltage and motor inductance ratio, and limiting the torque command to the smaller of the physical torque limit and the theoretical torque limit. Receiving the torque command may include normalizing the torque command to obtain a normalized torque command, determining the physical torque limit may include determining a normalized physical torque limit, determining a theoretical torque limit may include determining a normalized theoretical torque limit, and limiting the torque command may include limiting the normalized torque command to the smaller of the normalized physical torque limit and the normalized theoretical torque limit.

  7. Deformation of a micro-torque swimmer

    PubMed Central

    Ishikawa, Takuji; Tanaka, Tomoyuki; Imai, Yohsuke; Omori, Toshihiro; Matsunaga, Daiki

    2016-01-01

    The membrane tension of some kinds of ciliates has been suggested to regulate upward and downward swimming velocities under gravity. Despite its biological importance, deformation and membrane tension of a ciliate have not been clarified fully. In this study, we numerically investigated the deformation of a ciliate swimming freely in a fluid otherwise at rest. The cell body was modelled as a capsule with a hyperelastic membrane enclosing a Newtonian fluid. Thrust forces due to the ciliary beat were modelled as torques distributed above the cell body. The effects of membrane elasticity, the aspect ratio of the cell's reference shape, and the density difference between the cell and the surrounding fluid were investigated. The results showed that the cell deformed like a heart shape, when the capillary number was sufficiently large. Under the influence of gravity, the membrane tension at the anterior end decreased in the upward swimming while it increased in the downward swimming. Moreover, gravity-induced deformation caused the cells to move gravitationally downwards or upwards, which resulted in a positive or negative geotaxis-like behaviour with a physical origin. These results are important in understanding the physiology of a ciliate's biological responses to mechanical stimuli. PMID:26997893

  8. Acute achilles tendon repair: strength outcomes after an acute bout of exercise in recreational athletes.

    PubMed

    Porter, David A; Barnes, Adam F; Rund, Angela M; Kaz, Ari J; Tyndall, James A; Millis, Andrew A

    2014-02-01

    This is the first study to evaluate the effect of an acute bout of exercise on strength evaluation after Achilles tendon (AT) rupture and repair. Forty patients sustained an acute AT injury and met inclusion criteria for this study. At a minimum of 12 months after operative repair, patients were measured for (1) calf circumference, (2) bilateral isokinetic strength on a Cybex dynamometer before and after 30 minutes of walking at 70% maximal exertion, and (3) subjective evaluation by AAOS lower limb core and foot and ankle modules. Follow-up occurred at a mean of 32.4 ± 20.7 (range, 12-80) months after surgery, and patients were on average 44.4 ± 8.6 (range, 20-62) years old. One-tailed Student's paired t tests analyzed significance for strength and fatigue between the involved and uninvolved ankle (P < .05). The calf circumference of the involved ankle was significantly smaller than the uninvolved ankle by 1.9 cm, or 4.7%. Plantarflexion deficits of the involved ankle ranged from 12% to 18% for peak torque (P < .0001) and from 17% to 25% for work per repetition (P < .0001), but both ankles fatigued at equal proportions as measured after exercise. Dorsiflexion strength of the involved ankle increased 6% to 11% for peak torque (P = .070) and 1% to 25% for peak work (P = .386). Reported AAOS lower limb core and foot and ankle scores averaged 99.8 and 96.0, respectively. After an AT rupture with repair, patients had less plantarflexion strength, and equal dorsiflexion strength in the operative leg compared to the uninvolved, normal leg. However, subjective results indicated near normal pain and function despite mild plantarflexion strength deficits. Dorsiflexion strength was normal after repair and remained normal even after an acute bout of exercise. Plantarflexion strength ratios postexercise remained similar to pre-exercise after acute exercise bouts. Athletes reported a "flat tire" feeling while running, which suggests a probable gait adjustment as cause for long-term plantarflexion strength deficits. Level III, cohort study.

  9. [The application of contralateral acupuncture for rehabilitation after acute closed achilles tendon rupture].

    PubMed

    Zhang, Dawei; Ye, Xiangming; Zhang, Xiaofeng; Zhang, Wenjie

    2017-03-12

    To observe the differences of affected-side ankle plantar flexors function and clinical efficacy between contralateral acupuncture combined with rehabilitation training and rehabilitation training alone for patients with acute closed achilles tendon rupture. Seventy-four patients with acute closed achilles tendon rupture were randomly assigned to an observation group and a control group, 37 cases in each group. Patients in the both groups were treated with routine rehabilitation training after the operation for 12 weeks; besides, patients in the observation group were treated with contralateral acupuncture at Zusanli (ST 36), Yanglingquan (GB 34), Chengshan (BL 57), Taixi (KI 3) before rehabilitation training in the first 6 weeks. The treatment were given once a day, 5 times as 1 course with 2 d at the interval. The Biodex System 4 multi-joint dynamometers system was applied to test and compare affected-side plantar flexion peak torque (PFPT), peak torque/body weight (PT/BW) and total work (TW) after 6 weeks, 8 weeks and 12 weeks. The efficacy evaluation was conducted after 6 weeks and 12 weeks, and the follow-up visit was conducted 12 weeks after end of treatment. The PFPT, PT/BW, TW in the observation group were significantly superior to those in the control group after 8 weeks and 12 weeks of treatment (all P <0.05); compared with those after 6 weeks, the PFPT, PT/BW, TW were significantly increased after 8 weeks of treatment (all P <0.05); compared with those after 6 weeks and 8 weeks, the PFPT, PT/BW, TW were significantly increased after 12 weeks of treatment (all P <0.05). After 12 weeks of treatment and at follow-up visit, the clinical excellent and effective rates in the observation group were higher than those in the control group[89.2% (33/37) vs 70.3% (26/37), 94.6% (35/37) vs 75.7% (28/37), both P <0.05]. During the postoperative rehabilitation of acute closed achilles tendon rupture, the contralateral acupuncture combined with rehabilitation training could improve ankle plantar flexors function and clinical efficacy better than rehabilitation training only.

  10. Electromechanical actuation for thrust vector control applications

    NASA Technical Reports Server (NTRS)

    Roth, Mary Ellen

    1990-01-01

    At present, actuation systems for the Thrust Vector Control (TVC) for launch vehicles are hydraulic systems. The Advanced Launch System (ALS), a joint initiative between NASA and the Air Force, is a launch vehicle that is designed to be cost effective, highly reliable and operationally efficient with a goal of reducing the cost per pound to orbit. As part of this initiative, an electromechanical actuation system is being developed as an attractive alternative to the hydraulic systems used today. NASA-Lewis is developing and demonstrating an Induction Motor Controller Actuation System with a 40 hp peak rating. The controller will integrate 20 kHz resonant link Power Management and Distribution (PMAD) technology and Pulse Population Modulation (PPM) techniques to implement Field Oriented Vector Control (FOVC) of a new advanced induction motor. Through PPM, multiphase variable frequency, variable voltage waveforms can be synthesized from the 20 kHz source. FOVC shows that varying both the voltage and frequency and their ratio (V/F), permits independent control of both torque and speed while operating at maximum efficiency at any point on the torque-speed curve. The driver and the FOVC will be microprocessor controlled. For increased system reliability, a Built-in Test (BITE) capability will be included. This involves introducing testability into the design of a system such that testing is calibrated and exercised during the design, manufacturing, maintenance and prelaunch activities. An actuator will be integrated with the motor controller for performance testing of the EMA TVC system. The design and fabrication of the motor controller is being done by General Dynamics Space Systems Division. The University of Wisconsin-Madison will assist in the design of the advanced induction motor and in the implementation of the FOVC theory. A 75 hp electronically controlled dynamometer will be used to test the motor controller in all four quadrants of operation using flight type control algorithms. Integrated testing of the controller and actuator will be conducted at a facility yet to be named. The EMA system described above is discussed in detail.

  11. Influence of prolonged intermittent high-intensity exercise on knee flexor strength in male and female soccer players.

    PubMed

    Mercer, Tom H; Gleeson, Nigel P; Wren, Karen

    2003-06-01

    This study investigated the effect of an acute, prolonged, intermittent, high-intensity single-leg pedalling exercise task (PIHIET) on the isokinetic leg strength of the knee flexors in six male and seven female collegiate soccer players. Following determination of single-leg VO(2peak), subjects completed a PIHIET designed to simulate the energetics of soccer match play (approximately 90 min in total; approximately 70% single-leg VO(2peak)). Pre-, mid- and post-PIHIET gravity-corrected indices of knee flexion peak torque (PT) and range of motion-relativised torque at 15% of knee flexion (RRT(15%); 0% = full knee extension) were assessed at a lever-arm angular velocity of 1.05 rad.s(-1)for intervention and control limbs using an isokinetic dynamometer. Repeated measures ANOVAs revealed significant condition (PIHIET, control) x time (pre-, mid-, post-PIHIET) interactions for knee flexion PT (F([2,22])=26.2; P<0.001) and RRT(15%) (F([2,22])=20.1; P<0.001). Flexion PT and RRT(15% )were observed to decrease, pre- to post-intervention, from 92.8 (28.7) N.m to 72.1 (28.0) N.m and from 63.8 (17.5) N.m to 47.9 (18.4) N.m respectively, for the intervention limb alone. These data corresponded to 22.3% and 24.9% mean reductions pre-post intervention in PT and RRT(15%). Exploratory post hoc analysis of the pattern of the relative deterioration (%) of PT and RRT(15%), for the intervention limb alone, revealed a three-way interaction [group (male, female) x parameter (PT, RRT(15%)) x assessment phase (pre- to mid-PIHIET, mid- to post-PIHIET)] (F(1,11)=5.2; P<0.05). This interaction characterised a greater deterioration of strength performance during the mid- to post-PIHIET assessment phase, at the extremes of range of motion (RRT(15%)) for the female group. The greater percentage of mid-post phase strength loss observed in women near the end-range extension may potentially be implicated in the higher incidence of knee injury reported in female soccer players.

  12. Development and Testing of an Integrated Rotating Dynamometer Based on Fiber Bragg Grating for Four-Component Cutting Force Measurement

    PubMed Central

    Liu, Mingyao; Bing, Junjun; Xiao, Li; Yun, Kang; Wan, Liang

    2018-01-01

    Cutting force measurement is of great importance in machining processes. Hence, various methods of measuring the cutting force have been proposed by many researchers. In this work, a novel integrated rotating dynamometer based on fiber Bragg grating (FBG) was designed, constructed, and tested to measure four-component cutting force. The dynamometer consists of FBGs that are pasted on the newly designed elastic structure which is then mounted on the rotating spindle. The elastic structure is designed as two mutual-perpendicular semi-octagonal rings. The signals of the FBGs are transmitted to FBG interrogator via fiber optic rotary joints and optical fiber, and the wavelength values are displayed on a computer. In order to determine the static and dynamic characteristics, many tests have been done. The results show that it is suitable for measuring cutting force. PMID:29670062

  13. Development and Testing of an Integrated Rotating Dynamometer Based on Fiber Bragg Grating for Four-Component Cutting Force Measurement.

    PubMed

    Liu, Mingyao; Bing, Junjun; Xiao, Li; Yun, Kang; Wan, Liang

    2018-04-18

    Cutting force measurement is of great importance in machining processes. Hence, various methods of measuring the cutting force have been proposed by many researchers. In this work, a novel integrated rotating dynamometer based on fiber Bragg grating (FBG) was designed, constructed, and tested to measure four-component cutting force. The dynamometer consists of FBGs that are pasted on the newly designed elastic structure which is then mounted on the rotating spindle. The elastic structure is designed as two mutual-perpendicular semi-octagonal rings. The signals of the FBGs are transmitted to FBG interrogator via fiber optic rotary joints and optical fiber, and the wavelength values are displayed on a computer. In order to determine the static and dynamic characteristics, many tests have been done. The results show that it is suitable for measuring cutting force.

  14. Prediction of Cutting Force in Turning Process-an Experimental Approach

    NASA Astrophysics Data System (ADS)

    Thangarasu, S. K.; Shankar, S.; Thomas, A. Tony; Sridhar, G.

    2018-02-01

    This Paper deals with a prediction of Cutting forces in a turning process. The turning process with advanced cutting tool has a several advantages over grinding such as short cycle time, process flexibility, compatible surface roughness, high material removal rate and less environment problems without the use of cutting fluid. In this a full bridge dynamometer has been used to measure the cutting forces over mild steel work piece and cemented carbide insert tool for different combination of cutting speed, feed rate and depth of cut. The experiments are planned based on taguchi design and measured cutting forces were compared with the predicted forces in order to validate the feasibility of the proposed design. The percentage contribution of each process parameter had been analyzed using Analysis of Variance (ANOVA). Both the experimental results taken from the lathe tool dynamometer and the designed full bridge dynamometer were analyzed using Taguchi design of experiment and Analysis of Variance.

  15. Torque Generation of Enterococcus hirae V-ATPase*

    PubMed Central

    Ueno, Hiroshi; Minagawa, Yoshihiro; Hara, Mayu; Rahman, Suhaila; Yamato, Ichiro; Muneyuki, Eiro; Noji, Hiroyuki; Murata, Takeshi; Iino, Ryota

    2014-01-01

    V-ATPase (VoV1) converts the chemical free energy of ATP into an ion-motive force across the cell membrane via mechanical rotation. This energy conversion requires proper interactions between the rotor and stator in VoV1 for tight coupling among chemical reaction, torque generation, and ion transport. We developed an Escherichia coli expression system for Enterococcus hirae VoV1 (EhVoV1) and established a single-molecule rotation assay to measure the torque generated. Recombinant and native EhVoV1 exhibited almost identical dependence of ATP hydrolysis activity on sodium ion and ATP concentrations, indicating their functional equivalence. In a single-molecule rotation assay with a low load probe at high ATP concentration, EhVoV1 only showed the “clear” state without apparent backward steps, whereas EhV1 showed two states, “clear” and “unclear.” Furthermore, EhVoV1 showed slower rotation than EhV1 without the three distinct pauses separated by 120° that were observed in EhV1. When using a large probe, EhVoV1 showed faster rotation than EhV1, and the torque of EhVoV1 estimated from the continuous rotation was nearly double that of EhV1. On the other hand, stepping torque of EhV1 in the clear state was comparable with that of EhVoV1. These results indicate that rotor-stator interactions of the Vo moiety and/or sodium ion transport limit the rotation driven by the V1 moiety, and the rotor-stator interactions in EhVoV1 are stabilized by two peripheral stalks to generate a larger torque than that of isolated EhV1. However, the torque value was substantially lower than that of other rotary ATPases, implying the low energy conversion efficiency of EhVoV1. PMID:25258315

  16. Long-term reliable physically unclonable function based on oxide tunnel barrier breakdown on two-transistors two-magnetic-tunnel-junctions cell-based embedded spin transfer torque magnetoresistive random access memory

    NASA Astrophysics Data System (ADS)

    Takaya, Satoshi; Tanamoto, Tetsufumi; Noguchi, Hiroki; Ikegami, Kazutaka; Abe, Keiko; Fujita, Shinobu

    2017-04-01

    Among the diverse applications of spintronics, security for internet-of-things (IoT) devices is one of the most important. A physically unclonable function (PUF) with a spin device (spin transfer torque magnetoresistive random access memory, STT-MRAM) is presented. Oxide tunnel barrier breakdown is used to realize long-term stability for PUFs. A secure PUF has been confirmed by evaluating the Hamming distance of a 32-bit STT-MRAM-PUF fabricated using 65 nm CMOS technology.

  17. The Relationship Between Lower Extremily Strength and Shoulder Overuse Symptoms: A Model Based on Polio Survivors

    DTIC Science & Technology

    1998-01-01

    developed based on a questionnaire designed to measure habitual physical activity.9 The survey 124 included specific activities that might predispose...manual strength examination was then performed by a physical therapist using a hand- 149 held dynamometer (Empi Microfet2, St. Paul, MN). The physical ...subject pushed against the padded dynamometer force plate, 157 which the physical therapist held stationary. The peak force was measured in pounds, and

  18. Proposed model for the flagellar rotary motor with shear stress transmission

    PubMed Central

    Mitsui, Toshio; Ohshima, Hiroyuki

    2012-01-01

    Most bacteria that swim are propelled by flagellar filaments, which are driven by a rotary motor powered by proton flux. The motor consists of the rotor and the stator. The stator consists of about 8 MotA-Mot B complex. There seems to be no definite information about the structure between the rotor and the stator, and it is examined whether the experimental data can be explained based upon the following assumptions. (a) There is viscoelastic medium between the rotor and the stator. (b) MotA-MotB complex has an electric dipole moment and produces shear stress in the electric field by a proton in the channel. Calculation results based upon these assumptions are in good agreement with the following experimental observations. (1) One revolution of the flagellar rotation consists of a constant number of steps. (2) The rotation velocity of the rotor is proportional to the trans-membrane potential difference. (3) When the rotational velocity of a flagellum is changed by adjusting the viscosity of the outer fluid, the torque for the cell to rotate a flagellum is practically constant but sharply decreases when the rotational velocity increases over a critical value. (4) The rotation direction remains the same when the sign of the electrochemical potential gradient is reversed. (5) The cell produces constant torque to rotate the flagellum even when the cell is rotated by externally applied torque. (6) A simple switch mechanism is proposed for chemotaxis. PMID:27493532

  19. Design of an Orthodontic Torque Simulator for Measurement of Bracket Deformation

    NASA Astrophysics Data System (ADS)

    Melenka, G. W.; Nobes, D. S.; Major, P. W.; Carey, J. P.

    2013-12-01

    The design and testing of an orthodontic torque simulator that reproduces the effect of archwire rotation on orthodontic brackets is described. This unique device is capable of simultaneously measuring the deformation and loads applied to an orthodontic bracket due to archwire rotation. Archwire rotation is used by orthodontists to correct the inclination of teeth within the mouth. This orthodontic torque simulator will provide knowledge of the deformation and loads applied to orthodontic bracket that will aide clinicians by describing the effect of archwire rotation on brackets. This will also impact that design on new archwirebracket systems by providing an assessment of performance. Deformation of the orthodontic bracket tie wings is measured using a digital image correlation process to measure elastic and plastic deformation. The magnitude of force and moments applied to the bracket though the archwire is also measured using a six-axis load cell. Initial tests have been performed on two orthodontic brackets of varying geometry to demonstrate the measurement capability of the orthodontic torque simulator. The demonstration experiment shows that a Damon Q bracket had a final plastic deformation after a single loading of 0.022 mm while the Speed bracket deformed 0.071 mm. This indicates that the Speed bracket plastically deforms 3.2 times more than the Damon Q bracket for similar magnitude of applied moment. The demonstration experiment demonstrates that bracket geometry affect the deformation of orthodontic brackets and this difference can be detected using the orthodontic torque simulator.

  20. Measuring Torque and Temperature in a Rotating Shaft Using Commercial SAW Sensors

    PubMed Central

    Silva, Diogo; Pereira, António B.; Gégot, François

    2017-01-01

    Real-time monitoring of torque in a rotating shaft is not easy to implement with technologies such as optic fiber sensors or strain gages. Surface acoustic wave (SAW) sensors are wireless and passive and can be used to monitor strain in moving parts. Commercial solutions (sensors, antennas and interrogation unit) can easily be purchased from some companies; however, they are not customized and may not meet the specificity of the measurements. In order to evaluate the adequacy of commercial off-the-shelf (COTS) solutions, temperature and strain sensors fabricated by SENSeOR (Besançon, France) were mounted on a load cell. The sensors were calibrated using a thermal chamber and a universal testing machine. The load cell was then assembled together with a steel shaft that rotated at different speeds inside an oven. The commercial antennas were replaced with an RF (radio frequency) coupler and the sensors were interrogated with the commercial interrogation unit. The influence of rotation in the accuracy on the measurements, as well as the adequacy of the sensors structure, was evaluated. It can be concluded that SAW sensors can be used to measure temperature or torque in a rotating environment; however, some customization of the components is required in order to overcome the limitations posed by COTS sensing solutions. PMID:28671594