Sample records for ear deformities tomographic

  1. Effectiveness of Ear Splint Therapy for Ear Deformities

    PubMed Central

    2017-01-01

    Objective To present our experience with ear splint therapy for babies with ear deformities, and thereby demonstrate that this therapy is an effective and safe intervention without significant complications. Methods This was a retrospective study of 54 babies (35 boys and 19 girls; 80 ears; age ≤3 months) with ear deformities who had received ear splint therapy at the Center for Torticollis, Department of Physical Medicine and Rehabilitation, Ajou University Hospital between December 2014 and February 2016. Before the initiation of ear splint therapy, ear deformities were classified with reference to the standard terminology. We compared the severity of ear deformity before and after ear splint therapy by using the physician's ratings. We also compared the physician's ratings and the caregiver's ratings on completion of ear splint therapy. Results Among these 54 babies, 41 children (58 ears, 72.5%) completed the ear splint therapy. The mean age at initiation of therapy was 52.91±18.26 days and the treatment duration was 44.27±32.06 days. Satyr ear, forward-facing ear lobe, Darwinian notch, overfolded ear, and cupped ear were the five most common ear deformities. At the completion of therapy, the final physician's ratings of ear deformities were significantly improved compared to the initial ratings (8.28±1.44 vs. 2.51±0.92; p<0.001). There was no significant difference between the physician's ratings and the caregiver's ratings at the completion of ear splint therapy (8.28±1.44 vs. 8.0±1.61; p=0.297). Conclusion We demonstrated that ear splint therapy significantly improved ear deformities in babies, as measured by quantitative rating scales. Ear splint therapy is an effective and safe intervention for babies with ear deformities. PMID:28289646

  2. Unclassified congenital deformities of the external ear.

    PubMed

    Vathulya, Madhubari

    2018-01-01

    Congenital ear deformities are a common entity. They are found in isolation or as a part of syndrome in patients. They may involve the external, middle or inner ear or in any of these combinations. Three patients of different ages presented with deformities including mirror image duplication of the superior auricle, unclassified deformities of ear lobule (wavy lobule) and deformity of superior auricle with unclassified variety of lateral ear pit. This article highlights that there are further cases of ear deformities that are noticed in the general population who come for cosmetic correction, and hence, there is a need for further modifying the classification of ear deformities.

  3. Ear molding in newborn infants with auricular deformities.

    PubMed

    Byrd, H Steve; Langevin, Claude-Jean; Ghidoni, Lorraine A

    2010-10-01

    A review of a single physician's experience in managing over 831 infant ear deformities (488 patients) is presented. The authors' methods of molding have advanced from the use of various tapes, glues, and stents, to a comprehensive yet simple system that shapes the antihelix, the triangular fossa, the helical rim, and the overly prominent conchal-mastoid angle (EarWell Infant Ear Correction System). The types of deformities managed, and their relative occurrence, are as follows: (1) prominent/cup ear, 373 ears (45 percent); (2) lidding/lop ear, 224 ears (27 percent); (3) mixed ear deformities, 83 ears (10 percent) (all had associated conchal crus); (4) Stahl's ear, 66 ears (8 percent); (5) helical rim abnormalities, 58 ears (7 percent); (6) conchal crus, 25 ears (3 percent); and (7) cryptotia, two ears (0.2 percent). Bilateral deformities were present in 340 patients (70 percent), with unilateral deformities in 148 patients (30 percent). Fifty-eight infant ears (34 patients) were treated using the final version of the EarWell Infant Ear Correction System with a success rate exceeding 90 percent (good to excellent results). The system was found to be most successful when begun in the first week of the infant's life. When molding was initiated after 3 weeks from birth, only approximately half of the infants had a good response. Congenital ear deformities are common and only approximately 30 percent self-correct. These deformities can be corrected by initiating appropriate molding in the first week of life. Neonatal molding reduces the need for surgical correction with results that often exceed what can be achieved with the surgical alternative.

  4. Correction of Stahl ear deformity using a suture technique.

    PubMed

    Khan, Muhammad Adil Abbas; Jose, Rajive M; Ali, Syed Nadir; Yap, Lok Huei

    2010-09-01

    Correction of partial ear deformities can be a challenging task for the plastic surgeon. There are no standard techniques for correcting many of these deformities, and several different techniques are described in literature. Stahl ear is one such anomaly, characterized by an accessory third crus in the ear cartilage, giving rise to an irregular helical rim. The conventional techniques of correcting this deformity include either excision of the cartilage, repositioning of the cartilage, or scoring techniques. We recently encountered a case of Stahl ear deformity and undertook correction using internal sutures with very good results. The technical details of the surgery are described along with a review of literature on correcting similar anomalies.

  5. [Plastic surgery to correct deformities of the ear].

    PubMed

    Naumann, A

    2005-08-18

    For the plastic-surgical correction of mild deformities of the ears, well-proven incisional and suturing techniques are available. Only in exceptional cases is skin grafting or the use of cartilage ersatz material required. In the plastic surgical treatment of moderate to severe ear deformities, in contrast, not only incisional and suturing techniques, but also free skin grafts and ersatz materials are needed. At the ENT Department of the Ludwig-Maximilian University in Munich, plastic reconstruction of moderate to severe deformities of the external ear using porous polyethylene implants instead of rib cartilage grafts has been practiced with success for the past two years or so. Porous polyethylene implants provide good results and may help to avoid pre- and postoperative morbidity at donor site defects.

  6. Mozart Ear Deformity: a Rare Diagnosis in the Ear Reconstruction Clinic.

    PubMed

    Telich-Tarriba, Jose E; Victor-Baldin, Andre; Apellaniz-Campo, Armando

    2017-07-01

    Mozart ear is a rare auricular deformity; clinically the auricle is characterized by the bulging appearance of the anterosuperior portion of the auricle due to fusion of the crura of the antihelix, an inversion in the normal form of the cavum conchae resulting in its convexity and a slit-like narrowing of the orifice of the external auditory meatus.A retrospective review of clinical and photographic records of patients attended at the ear reconstruction clinic of our hospital between June of 2010 and May 2016 was performed; out of 576 consecutive patients only 3 fulfilled the inclusion criteria, with a prevalence of 0.5%. The authors present these patients.Surgical interventions mainly focus on the correction of the convex concha; however, the procedure should be tailored to the severity of the deformity and the wishes of the patient.

  7. Auricular hematoma and cauliflower deformation of the ear: from art to medicine.

    PubMed

    Mudry, Albert; Pirsig, Wolfgang

    2009-01-01

    Auricular hematoma and cauliflower deformation of the ear are unique in several respects. Knowledge about it began, in antiquity, through artists, particularly Greek and Roman, and then Japanese in the 18th century with their representation of cauliflower deformation of the ear on sculptures and paintings of pugilists and wrestlers. It is only in the 19th century that physicians began to make substantive progress in understanding this abnormality. It was first thought to be associated with mental disease, but by the beginning of the 20th century, its etiology was recognized as being caused by trauma and was then named auricular hematoma. The second step in the understanding of this affliction was the observation that auricular hematoma progresses toward cauliflower deformation of the ear, which was named cauliflower ear. Recognition of this evolution led to the development of therapies. During the second half of the 20th century, different treatments were developed. They included various hematoma drainage techniques with special bandages to prevent hematoma recurrence and ensuing progression to cauliflower ear. In summary, cauliflower deformation of the ear is an old artistic affliction that has only recently received medical attention.

  8. Correction of Congenital Auricular Deformities Using the Ear-Molding Technique.

    PubMed

    Woo, Taeyong; Kim, Young Seok; Roh, Tai Suk; Lew, Dae Hyun; Yun, In Sik

    2016-11-01

    Studies of the ear-molding technique have emphasized the importance of initiating molding early to achieve the best results. In the present study, we describe the immediate effects and long-term outcomes of this technique, focusing on children who were older than the ideal age of treatment initiation. Patients who visited our institution from July 2014 to November 2015 were included. Medical charts were reviewed to collect data on demographics, the duration of treatment, the types of deformities, and the manner of recognition of the deformity and referral to our institution. Parents were surveyed to assess the degree of improvement, the level of procedural discomfort at the end of treatment, any changes in the shape of the molded auricle, and overall satisfaction 12 months after their last follow-up visits. A review of 28 ears in 18 patients was conducted, including the following types of deformities: constricted ear (64.2%), Stahl ear (21.4%), prominent ear (7.1%), and cryptotia (7.1%). The average score for the degree of improvement, rated on a 5-point scale (1, very poor; 5, excellent), was 3.5 at the end of treatment, with a score of 2.6 for procedural discomfort (1, very mild; 5, very severe). After 12 months, the shapes of all ears were well maintained. The average overall satisfaction score was 3.6 (1, very dissatisfied; 5, very satisfied). We had reasonable outcomes in older patients. After 1 year of follow-up, these outcomes were well maintained. Patients past the ideal age at presentation can still be candidates for the molding technique.

  9. Proposal of a Classification System for the Assessment and Treatment of Prominent Ear Deformity.

    PubMed

    Lee, Youngdae; Kim, Young Seok; Lee, Won Jai; Rha, Dong Kyun; Kim, Jiye

    2018-06-01

    Prominent ear is the most common external ear deformity. To comprehensively treat prominent ear deformity, adequate comprehension of its pathophysiology is crucial. In this article, we analyze cases of prominent ear and suggest a simple classification system and treatment algorithm according to pathophysiology. We retrospectively reviewed a total of 205 Northeast Asian patients' clinical data who underwent an operation for prominent ear deformity. Follow-up assessments were conducted 3, 6, and 12 months after surgery. Prominent ear deformities were classified by diagnostic checkpoints. Class I (simple prominent ear) includes prominent ear that developed with the absence of the antihelix without conchal hypertrophy. Class II (mixed-type prominent ear) is defined as having not only a flat antihelix, but also conchal excess. Class III (conchal-type prominent ear) has an enlarged conchal bowl with a well-developed antihelix. Among the three types of prominent ear, class I was most frequent (162 patients, 81.6%). Class II was observed in 28 patients (13.6%) and class III in 10 patients (4.8%). We used the scaphomastoid suture method for correction of antihelical effacement, the anterior approach conchal resection for correction of conchal hypertrophy, and Bauer's squid incision for lobule prominence. The complication rate was 9.2% including early hematoma, hypersensitivity, and suture extrusion. Unfavorable results occurred in 4% including partial recurrence, overcorrection, and undercorrection. To reduce unfavorable results and avoid recurrence, we propose the use of a classification and treatment algorithm in preoperative evaluation of prominent ear. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  10. Correction of the bilateral question mark ear deformity using double-opposing z-plasty and a chondrocutaneous flap.

    PubMed

    Bastidas, Nicholas; Taylor, Jesse A

    2013-03-01

    To describe an alternative technique for correcting a rare and complex ear deformity. The question mark ear deformity has been described as a congenital cleft between the helix and the lobule in addition to a prominent ear. Here we describe a novel technique using double-opposing Z-plasty and a chondrocutaneous flap to correct the deformity without significant reduction in auricle height or creation of a donor-site defect. An anterior/posterior double-opposing Z-plasty and a superiorly based chondrocutaneous flap were designed at the level of the cleft. Flaps were raised full thickness, and Mustarde and Furnas sutures were placed to reduce the prominence. The flaps were then transposed and reapproximated. Of note, all anterior and posterior skin flaps were used in the repair to minimize diminution of ear height. Pre- and postoperative measurements and photographs of the ears were taken. Postoperatively, all flaps were viable, and there was no evidence of skin necrosis. The total length of the left ear was reduced by only 3 mm (53 to 50 mm), and the right ear was reduced by 1 mm (52 to 51 mm). The patient's pain was successfully managed as an outpatient, and there were no infectious complications. The resultant scars healed aesthetically and are minimally visible. The patient and her parents are satisfied with the results. Our technique addresses all components of the question mark ear deformity and does not create a visible donor-site deformity.

  11. Ear Deformations Give Bats a Physical Mechanism for Fast Adaptation of Ultrasonic Beam Patterns

    NASA Astrophysics Data System (ADS)

    Gao, Li; Balakrishnan, Sreenath; He, Weikai; Yan, Zhen; Müller, Rolf

    2011-11-01

    A large number of mammals, including humans, have intricate outer ear shapes that diffract incoming sound in a direction- and frequency-specific manner. Through this physical process, the outer ear shapes encode sound-source information into the sensory signals from each ear. Our results show that horseshoe bats could dynamically control these diffraction processes through fast nonrigid ear deformations. The bats’ ear shapes can alter between extreme configurations in about 100 ms and thereby change their acoustic properties in ways that would suit different acoustic sensing tasks.

  12. Spectacle fitting with ear, nose and face deformities or abnormalities.

    PubMed

    Eng, Helen; Chiu, Roger Sin Fai

    2002-11-01

    Spectacle frame selection and dispensing remain significant components of optometry. Occasionally, we encounter patients who are unable to wear conventional spectacles due to abnormalities or deformities following injury and/or surgery to their nose, ears or head. In these cases, spectacle frame fitting may be more complex and customized frame adjustments may be required to account for the anatomical variations. A patient with a microtia (hypoplastic pinna) was fitted with a tailored spectacle frame. The details are presented together with a summary of different frames and modifications available for ears, nose and face abnormalities.

  13. Classification of Newborn Ear Malformations and their Treatment with the EarWell Infant Ear Correction System.

    PubMed

    Daniali, Lily N; Rezzadeh, Kameron; Shell, Cheryl; Trovato, Matthew; Ha, Richard; Byrd, H Steve

    2017-03-01

    A single practice's treatment protocol and outcomes following molding therapy on newborn ear deformations and malformations with the EarWell Infant Ear Correction System were reviewed. A classification system for grading the severity of constricted ear malformations was created on the basis of anatomical findings. A retrospective chart/photograph review of a consecutive series of infants treated with the EarWell System from 2011 to 2014 was undertaken. The infants were placed in either deformation or malformation groups. Three classes of malformation were identified. Data regarding treatment induction, duration of treatment, and quality of outcome were collected for all study patients. One hundred seventy-five infant ear malformations and 303 infant ear deformities were treated with the EarWell System. The average age at initiation of treatment was 12 days; the mean duration of treatment was 37 days. An average of six office visits was required. Treated malformations included constricted ears [172 ears (98 percent)] and cryptotia [three ears (2 percent)]. Cup ear (34 ears) was considered a constricted malformation, in contrast to the prominent ear deformity. Constricted ears were assigned to one of three classes, with each subsequent class indicating increasing severity: class I, 77 ears (45 percent); class II, 81 ears (47 percent); and class III, 14 ears (8 percent). Molding therapy with the EarWell System reduced the severity by an average of 1.2 points (p < 0.01). Complications included minor superficial excoriations and abrasions. The EarWell System was shown to be effective in eliminating or reducing the need for surgery in all but the most severe malformations. Therapeutic, IV.

  14. Analysis of Facial Asymmetry in Deformational Plagiocephaly Using Three-Dimensional Computed Tomographic Review

    PubMed Central

    Moon, Il Yung; Oh, Kap Sung

    2014-01-01

    Background Infants with deformational plagiocephaly (DP) usually present with cranial vault deformities as well as facial asymmetry. The purpose of this study was to use three-dimensional anthropometric data to evaluate the influence of cranial deformities on facial asymmetry. Methods We analyzed three-dimensional computed tomography data for infants with DP (n=48) and without DP (n=30, control). Using 16 landmarks and 3 reference planes, 22 distance parameters and 2 angular parameters were compared. This cephalometric assessment focused on asymmetry of the orbits, nose, ears, maxilla, and mandible. We then assessed the correlation between 23 of the measurements and cranial vault asymmetry (CVA) for statistical significance using relative differences and correlation analysis. Results With the exception of few orbital asymmetry variables, most measurements indicated that the facial asymmetry was greater in infants with DP. Mandibular and nasal asymmetry was correlated highly with severity of CVA. Shortening of the ipsilateral mandibular body was particularly significant. There was no significant deformity in the maxilla or ear. Conclusion This study demonstrated that the cranial vault deformity in DP is associated with facial asymmetry. Compared with the control group, the infants with DP were found to have prominent asymmetry of the nose and mandible. PMID:28913202

  15. Surgical correction of constricted ear combined with Stahl's ear.

    PubMed

    Bi, Ye; Lin, Lin; Yang, Qinhua; Pan, Bo; Zhao, Yanyong; He, Leren; Jiang, Haiyue

    2015-07-01

    Constricted ear combined with Stahl's ear is a rare ear deformity, which is a kind of complex congenital auricular deformity. From 1 January 2007 to 1 January 2014, 19 patients with constricted ear combined with Stahl's ear (Spock ear) were enrolled in this study, most of which were unilaterally deformed. To correct the deformity, a double Z-shaped skin incision was made on the posterior side of the auricle, with the entire layer of cartilage cut parallel to the helix traversing the third crus to form a fan-shaped cartilage flap. The superior crura of the antihelix were shaped by the folding cartilage rim. The cartilage of the abnormal third crus was made part of the new superior crura of antihelix, and the third crus was eliminated. The postoperative aesthetic assessment of the reshaped auricle was graded by both doctors and patients (or their parents). Out of the 19 patients, the number of satisfying cases of the symmetry, helix stretch, elimination of the third crus, the cranioauricular angle, and the substructure of the reshaped ears was 14 (nine excellent and five good), 16 (six excellent and 10 good), 17 (eight excellent and nine good), 15 (five excellent and 10 good), and 13 (two excellent and 11 good), respectively. With a maximum of a 90-month follow-up, no complication was observed. The results of the study suggested that this rare deformity could be corrected by appropriate surgical treatment, with a satisfied postoperative appearance. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. Surgical correction of cauliflower ear.

    PubMed

    Yotsuyanagi, T; Yamashita, K; Urushidate, S; Yokoi, K; Sawada, Y; Miyazaki, S

    2002-07-01

    We have classified the cauliflower ear into different types according to the zone and the degree of deformity. One major group is deformity without change in the outline of the ear, and this is divided into four subgroups according to the zone. All of these subgroups can be treated by shaving the deformed cartilage through suitable incision lines. For deformities accompanied by a skin deficit, a postauricular skin flap should be used. The other major group is deformity accompanied by a change in the outline of the ear, which is divided into two subgroups. If the ear is rigid, a conchal cartilage graft is used. If the structural integrity of the ear is poor, costal cartilage is used to provide rigidity.

  17. The visible ear simulator: a public PC application for GPU-accelerated haptic 3D simulation of ear surgery based on the visible ear data.

    PubMed

    Sorensen, Mads Solvsten; Mosegaard, Jesper; Trier, Peter

    2009-06-01

    Existing virtual simulators for middle ear surgery are based on 3-dimensional (3D) models from computed tomographic or magnetic resonance imaging data in which image quality is limited by the lack of detail (maximum, approximately 50 voxels/mm3), natural color, and texture of the source material.Virtual training often requires the purchase of a program, a customized computer, and expensive peripherals dedicated exclusively to this purpose. The Visible Ear freeware library of digital images from a fresh-frozen human temporal bone was segmented, and real-time volume rendered as a 3D model of high-fidelity, true color, and great anatomic detail and realism of the surgically relevant structures. A haptic drilling model was developed for surgical interaction with the 3D model. Realistic visualization in high-fidelity (approximately 125 voxels/mm3) and true color, 2D, or optional anaglyph stereoscopic 3D was achieved on a standard Core 2 Duo personal computer with a GeForce 8,800 GTX graphics card, and surgical interaction was provided through a relatively inexpensive (approximately $2,500) Phantom Omni haptic 3D pointing device. This prototype is published for download (approximately 120 MB) as freeware at http://www.alexandra.dk/ves/index.htm.With increasing personal computer performance, future versions may include enhanced resolution (up to 8,000 voxels/mm3) and realistic interaction with deformable soft tissue components such as skin, tympanic membrane, dura, and cholesteatomas-features some of which are not possible with computed tomographic-/magnetic resonance imaging-based systems.

  18. Optical and tomographic imaging of a middle ear malformation in the bullfrog (Rana catesbeiana).

    PubMed

    Horowitz, Seth S; Simmons, Andrea Megela; Ketten, Darlene R

    2005-08-01

    Using a combination of in vivo computerized tomography and histological staining, a middle ear anomaly in two wild-caught American bullfrogs (Rana catesbeiana) is characterized. In these animals, the tympanic membrane, extrastapes, and pars media (shaft) of the stapes are absent on one side of the head, with the other side exhibiting normal morphology. The pars interna (footplate) of the stapes and the operculum are present in their normal positions at the entrance of the otic capsule on both the affected and unaffected sides. The pattern of deformity suggests a partial failure of development of tympanic pathway tissues, but with a preservation of the opercularis pathway. While a definitive proximate cause of the condition could not be determined, the anomalies show similarities to developmental defects in mammalian middle ear formation.

  19. Optical and tomographic imaging of a middle ear malformation in the bullfrog (Rana catesbeiana)

    PubMed Central

    Horowitz, Seth S.; Simmons, Andrea Megela; Ketten, Darlene R.

    2005-01-01

    Using a combination of in vivo computerized tomography and histological staining, a middle ear anomaly in two wild-caught American bullfrogs (Rana catesbeiana) is characterized. In these animals, the tympanic membrane, extrastapes, and pars media (shaft) of the stapes are absent on one side of the head, with the other side exhibiting normal morphology. The pars interna(footplate) of the stapes and the operculum are present in their normal positions at the entrance of the otic capsule on both the affected and unaffected sides. The pattern of deformity suggests a partial failure of development of tympanic pathway tissues, but with a preservation of theopercularis pathway. While a definitive proximate cause of the condition could not be determined, the anomalies show similarities to developmental defects in mammalian middle ear formation. PMID:16158670

  20. Nasal septal deformities in ear, nose, and throat patients: an international study.

    PubMed

    Mladina, Ranko; Cujić, Emil; Subarić, Marin; Vuković, Katarina

    2008-01-01

    The purpose of this study was to investigate the incidence and characteristics of nasal septum deformities in ear, nose, and throat (ENT) patients in various geographic regions in the world. Anterior rhinoscopy without nasal decongestion was performed in 17 ENT centers in 14 countries. The septal deformities were classified according to the classification system proposed by Mladina. A total of 2589 adult ENT patients (1500 males and 1089 females) were examined. Septal deformities were found in 89.2% of subjects. Left-sided deformities were slightly more prevalent than right-sided deformities (51.6% and 48.4%, respectively). The most frequent type of deformity was type 3 (20.4%). Straight septum was found in 15.4% of females and 7.5% of males. Almost 90% of the subjects showed 1 of the 7 types of septal deformity. There were no statistically significant differences in the incidence of their appearance among particular geographic regions. Type 3 was the most frequent type. Straight septum was twice as frequent in females than in males.

  1. Inverted u-shaped purse and rotation flaps: correcting the inferoposterior deformity of reconstructed ears after canaloplasty of the external auditory meatus.

    PubMed

    Ji, Chenyang; Zhang, Jinming; An, Geng; Liang, Weiqiang; Pan, Shujuan; Chen, Yuhong; Wei, Zhe; Zhang, Ganlin

    2012-06-01

    After patients with congenital microtia receive external ear canal plasty, the mastoid area usually has insufficient space for ear reconstruction. Hence, after ear reconstruction, an inferoposterior position deformity of the ear appears to some extent. Using inverted U-shaped purse and rotation flaps can correct this deformity effectively. From May of 2009 to September of 2011, five patients received the described procedures in the authors' department. Inverted U-shaped purse and rotation flaps were used for all the patients. The inverted U-shaped purse flap was used to reduce the area of the canal orifice and to lower the position, and the rotation flap was applied to turn the ear in a more superoposterior position. Two patients also received full-thickness skin grafting to cover the secondary wound. In four patients, V-Y-plasty or Z-plasty was used to adjust the flap transition. For the five patients, the distances between the ear antihelix and canal orifice were shortened, and the areas of the canal orifice were diminished. The retroversion of the auricle was corrected in various degrees, and the angles of the long axis of the auricle and the horizontal line were increased an average of 14.4°. The vertical distance between the top of the helix and the center of the canal orifice was increased an average of 15.2 mm. A slight dog ear deformity in front of the crus of the helix was left after the operation, but it was alleviated in the follow-up period. By using inverted U-shaped purse and rotation flaps, the inferoposterior position deformity of the reconstructed ear after external ear canal plasty in congenital microtia can be resolved effectively. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors http://www.springer.com/00266.

  2. Ear canal dynamic motion as a source of power for in-ear devices

    NASA Astrophysics Data System (ADS)

    Delnavaz, Aidin; Voix, Jérémie

    2013-02-01

    Ear canal deformation caused by temporomandibular joint (jaw joint) activity, also known as "ear canal dynamic motion," is introduced in this paper as a candidate source of power to possibly recharge hearing aid batteries. The geometrical deformation of the ear canal is quantified in 3D by laser scanning of different custom ear moulds. An experimental setup is proposed to measure the amount of power potentially available from this source. The results show that 9 mW of power is available from a 15 mm3 dynamic change in the ear canal volume. Finally, the dynamic motion and power capability of the ear canal are investigated in a group of 12 subjects.

  3. The constricted ear.

    PubMed

    Paredes, Alfredo A; Williams, J Kerwin; Elsahy, Nabil I

    2002-04-01

    The constricted ear may be described best as a pursestring closure of the ear. The deformity may include lidding of the upper pole with downward folding, protrusion of the concha, decreased vertical height, and low ear position relative to the face. The goals of surgical correction should include obtaining symmetry and correcting the intra-auricular anatomy. The degree of intervention is based on the severity of the deformity and may range from simple repositioning, soft tissue rearrangement, or manipulation of the cartilage. Multiple surgical techniques are described.

  4. Could ionizing radiation forestall cauliflower ear?

    PubMed

    Hwang, K; Kim, C W; Lee, S I; Park, I S; Kim, W C; Loh, J J

    2001-02-01

    Repeated trauma to the ear very often results in "cauliflower ear." Many methods have been suggested to prevent an injured ear from demonstrating a cauliflowerlike deformity. The principles of treatment are evacuation of the hematoma, control of the reaccumulation of fluid, and maintenance of the cartilage contour. The authors studied the effect of ionizing radiation on deformed rabbit ears induced by repeated trauma. Twenty ears (10 rabbits) were used in the experiment. The animals were divided into four groups (control, preradiation, low dose, and high dose). Hematoma was produced by pounding the lateral side of the auricle 10 times with a 50-g weight at a height of 15 cm. The thickness of the injured and uninjured sites was measured, and histological analysis was performed for each group. The thickness of the ears of the irradiated groups was significantly less than the control group. The authors think that radiation treatment of repeatedly injured ears could prevent ear deformity, and could possibly be an adjunctive form of management of cauliflower ear in addition to hematoma evacuation and compression therapy.

  5. Neonatal Ear Molding: Timing and Technique.

    PubMed

    Anstadt, Erin Elizabeth; Johns, Dana Nicole; Kwok, Alvin Chi-Ming; Siddiqi, Faizi; Gociman, Barbu

    2016-03-01

    The incidence of auricular deformities is believed to be ∼11.5 per 10,000 births, excluding children with microtia. Although not life-threatening, auricular deformities can cause undue distress for patients and their families. Although surgical procedures have traditionally been used to reconstruct congenital auricular deformities, ear molding has been gaining acceptance as an efficacious, noninvasive alternative for the treatment of newborns with ear deformations. We present the successful correction of bilateral Stahl's ear deformity in a newborn through a straightforward, nonsurgical method implemented on the first day of life. The aim of this report is to make pediatric practitioners aware of an effective and simple molding technique appropriate for correction of congenital auricular anomalies. In addition, it stresses the importance of very early initiation of ear cartilage molding for achieving the desired outcome. Copyright © 2016 by the American Academy of Pediatrics.

  6. Ear Scaffold Reconstruction Using Ultrasonic Aspirator for Cauliflower Ear.

    PubMed

    Hao, Scarlett; Angster, Kristen; Hubbard, Fleesie; Greywoode, Jewel; Vakharia, Kalpesh T

    2018-04-01

    Untreated auricular hematomas from ear trauma can result in an ear deformation known as cauliflower ear, secondary to fibrosis and new cartilage overgrowth. Cauliflower ear reconstruction has traditionally utilized tools such as a drill or a scalpel in order to improve auricular cosmesis. We present a case report utilizing an ultrasonic aspirator to recontour the fibrosed cartilage of a cauliflower ear. The ultrasonic aspirator has advantages over traditional tools in its ability to provide finely controlled bone removal without damage to surrounding soft tissue. The patient in this case report underwent multistage reconstruction using the ultrasonic aspirator with excellent cosmetic result and patient satisfaction.

  7. Bilateral cauliflower ear deformity: an unusual presentation of cutaneous Rosai-Dorfman disease.

    PubMed

    Oo, Kenneth K K; Pang, Yoke T; Thamboo, Thomas P

    2004-03-01

    This case illustrates the variety of clinical presentations of Rosai-Dorfman disease. In this case, the disease presented as bilateral cauliflower ear deformity and was diagnosed on the basis of typical pathological findings. Although the cause of this disease is not fully understood, it is hoped that, with increased awareness and the identification of more cases, more questions may be answered with respect to this interesting condition that was so elegantly described by Rosai and Dorfman more than three decades ago.

  8. Prenatal evaluation of the middle ear and diagnosis of middle ear hypoplasia using MRI.

    PubMed

    Katorza, Eldad; Nahama-Allouche, Catherine; Castaigne, Vanina; Gonzales, Marie; Galliani, Eva; Marlin, Sandrine; Jouannic, Jean-Marie; Rosenblatt, Jonathan; le Pointe, Hubert Ducou; Garel, Catherine

    2011-05-01

    Analysis of the middle ear with fetal MRI has not been previously reported. To show the contribution of fetal MRI to middle ear imaging. The tympanic cavity was evaluated in 108 fetal cerebral MRI examinations (facial and/or cerebral malformation excluded) and in two cases, one of Treacher Collins syndrome (case 1) and the other of oculo-auriculo-vertebral (OUV) spectrum (case 2) with middle ear hypoplasia identified by MRI at 27 and 36 weeks' gestation, respectively. In all 108 fetuses (mean gestational age 32.5 weeks), the tympanic cavity and T2 hypointensity related to the ossicles were well visualised on both sides. Case 1 had micro/retrognathia and bilateral external ear deformity and case 2 had retrognathism with a left low-set and deformed ear. MRI made it possible to recognize the marked hypoplasia of the tympanic cavity, which was bilateral in case 1 and unilateral in case 2. Both syndromes are characterized by craniofacial abnormalities including middle ear hypoplasia, which cannot be diagnosed with US. The middle ear cavity can be visualized with fetal MRI. We emphasize the use of this imaging modality in the diagnosis of middle ear hypoplasia.

  9. Deformable 3D-2D registration for CT and its application to low dose tomographic fluoroscopy

    NASA Astrophysics Data System (ADS)

    Flach, Barbara; Brehm, Marcus; Sawall, Stefan; Kachelrieß, Marc

    2014-12-01

    Many applications in medical imaging include image registration for matching of images from the same or different modalities. In the case of full data sampling, the respective reconstructed images are usually of such a good image quality that standard deformable volume-to-volume (3D-3D) registration approaches can be applied. But research in temporal-correlated image reconstruction and dose reductions increases the number of cases where rawdata are available from only few projection angles. Here, deteriorated image quality leads to non-acceptable deformable volume-to-volume registration results. Therefore a registration approach is required that is robust against a decreasing number of projections defining the target position. We propose a deformable volume-to-rawdata (3D-2D) registration method that aims at finding a displacement vector field maximizing the alignment of a CT volume and the acquired rawdata based on the sum of squared differences in rawdata domain. The registration is constrained by a regularization term in accordance with a fluid-based diffusion. Both cost function components, the rawdata fidelity and the regularization term, are optimized in an alternating manner. The matching criterion is optimized by a conjugate gradient descent for nonlinear functions, while the regularization is realized by convolution of the vector fields with Gaussian kernels. We validate the proposed method and compare it to the demons algorithm, a well-known 3D-3D registration method. The comparison is done for a range of 4-60 target projections using datasets from low dose tomographic fluoroscopy as an application example. The results show a high correlation to the ground truth target position without introducing artifacts even in the case of very few projections. In particular the matching in the rawdata domain is improved compared to the 3D-3D registration for the investigated range. The proposed volume-to-rawdata registration increases the robustness regarding sparse

  10. Influence of Rotator Cuff Tear Size and Repair Technique on the Creation and Management of Dog Ear Deformities in a Transosseous-Equivalent Rotator Cuff Repair Model

    PubMed Central

    Redler, Lauren H.; Byram, Ian R.; Luchetti, Timothy J.; Tsui, Ying Lai; Moen, Todd C.; Gardner, Thomas R.; Ahmad, Christopher S.

    2014-01-01

    Background: Redundancies in the rotator cuff tissue, commonly referred to as “dog ear” deformities, are frequently encountered during rotator cuff repair. Knowledge of how these deformities are created and their impact on rotator cuff footprint restoration is limited. Purpose: The goals of this study were to assess the impact of tear size and repair method on the creation and management of dog ear deformities in a human cadaveric model. Study Design: Controlled laboratory study. Methods: Crescent-shaped tears were systematically created in the supraspinatus tendon of 7 cadaveric shoulders with increasing medial to lateral widths (0.5, 1.0, and 1.5 cm). Repair of the 1.5-cm tear was performed on each shoulder with 3 methods in a randomized order: suture bridge, double-row repair with 2-mm fiber tape, and fiber tape with peripheral No. 2 nonabsorbable looped sutures. Resulting dog ear deformities were injected with an acrylic resin mixture, digitized 3-dimensionally (3D), and photographed perpendicular to the footprint with calibration. The volume, height, and width of the rotator cuff tissue not in contact with the greater tuberosity footprint were calculated using the volume injected, 3D reconstructions, and calibrated photographs. Comparisons were made between tear size, dog ear measurement technique, and repair method utilizing 2-way analysis of variance and Student-Newman-Keuls multiple-comparison tests. Results: Utilizing 3D digitized and injection-derived volumes and dimensions, anterior dog ear volume, height, and width were significantly smaller for rotator cuff repair with peripheral looped sutures compared with a suture bridge (P < .05) or double-row repair with 2-mm fiber tape alone (P < .05). Similarly, posterior height and width were significantly smaller for repair with looped peripheral sutures compared with a suture bridge (P < .05). Dog ear volumes and heights trended larger for the 1.5-cm tear, but this was not statistically significant

  11. JS-X syndrome: A multiple congenital malformation with vocal cord paralysis, ear deformity, hearing loss, shoulder musculature underdevelopment, and X-linked recessive inheritance.

    PubMed

    Hoeve, Hans L J; Brooks, Alice S; Smit, Liesbeth S

    2015-07-01

    We report on a family with a not earlier described multiple congenital malformation. Several male family members suffer from laryngeal obstruction caused by bilateral vocal cord paralysis, outer and middle ear deformity with conductive and sensorineural hearing loss, facial dysmorphisms, and underdeveloped shoulder musculature. The affected female members only have middle ear deformity and hearing loss. The pedigree is suggestive of an X-linked recessive inheritance pattern. SNP-array revealed a deletion and duplication on Xq28 in the affected family members. A possible aetiology is a neurocristopathy with most symptoms expressed in structures derived from branchial arches. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Intravertebral deformation in idiopathic scoliosis: a transverse plane computer tomographic study.

    PubMed

    Kotwicki, Tomasz; Napiontek, Marek

    2008-03-01

    The scoliotic vertebrae are submitted to (1) the displacement in the 3-dimensional space and (2) the bone remodeling, which results in a 3-dimensional intrinsic vertebral deformation. Both phenomena are most expressed inside the apical zone of the curve and can be measured in a computer tomographic (CT) scan. A comparative study of CT thoracic scans in scoliotic and normal children was performed to provide a better description of the altered anatomy with respect to patomechanism of scoliosis. Twenty-three scoliotic girls, aged 14.3 +/- 2.1 years, a case of a right thoracic curve with a Cobb angle of 60.6 +/- 19.3 degrees, and 24 controls, free of spinal deformity, sex- and age-matched, underwent CT examination of the thorax at the level of Th8 to Th9 vertebra. The rotation angle of the apical vertebra and the sagittal to coronal rib cage diameters ratio were measured. The intravertebral deformation was assessed by measuring the angles between the axis of the whole vertebra and the axes of the spinous or transverse processes. The ratio of sagittal to coronal chest diameter was reduced in scoliosis patients (P < 0.001) and correlated with the Cobb angle. The angle between the axis of vertebra and the spinous process increased (P = 0.008), and its value was positively correlated with the rotation angle of the vertebra (r = 0.78, P < 0.05); however, the rotation was oriented clockwise, whereas the spinous process deviation was counterclockwise. The angle between the spinous and the transverse process revealed greater values on the concave side (P < 0.001), whereas the transverse processes were not deviated from the axis of vertebra (P = 0.469). A constant pattern, previously not described, of the alteration of morphology of the apical vertebra due to the intravertebral bone remodeling was identified. The intravertebral deformation accompanied the displacement of the vertebra with a linear correlation; however, the 2 phenomena were developing in the opposite directions

  13. From labyrinthine aplasia to otocyst deformity.

    PubMed

    Giesemann, Anja Maria; Goetz, Friedrich; Neuburger, Jürgen; Lenarz, Thomas; Lanfermann, Heinrich

    2010-02-01

    Inner ear malformations (IEMs) are rare and it is unusual to encounter the rarest of them, namely labyrinthine aplasia (LA) and otocyst deformity. They do, however, provide useful pointers as to the early embryonic development of the ear. LA is characterised as a complete absence of inner ear structures. While some common findings do emerge, a clear definition of the otocyst deformity does not exist. It is often confused with the common cavity first described by Edward Cock. Our purpose was to radiologically characterise LA and otocyst deformity. Retrospective analysis of CT and MRI data from four patients with LA or otocyst deformity. Middle and inner ear findings were categorised by two neuroradiologists. The bony carotid canal was found to be absent in all patients. Posterior located cystic structures were found in association with LA and otocyst deformity. In the most severe cases, only soft tissue was present at the medial border of the middle ear cavity. The individuals with otocyst deformity also had hypoplasia of the petrous apex bone. These cases demonstrate gradual changes in the two most severe IEMs. Clarification of terms was necessary and, based on these findings, we propose defining otocyst deformity as a cystic structure in place of the inner ear, with the cochlea, IAC and carotid canal absent. This condition needs to be differentiated from the common cavity described by Edward Cook. A clear definition of inner ear malformations is essential if outcomes following cochlear implantation are to be compared.

  14. Middle ear osteoma causing progressive facial nerve weakness: a case report.

    PubMed

    Curtis, Kate; Bance, Manohar; Carter, Michael; Hong, Paul

    2014-09-18

    Facial nerve weakness is most commonly due to Bell's palsy or cerebrovascular accidents. Rarely, middle ear tumor presents with facial nerve dysfunction. We report a very unusual case of middle ear osteoma in a 49-year-old Caucasian woman causing progressive facial nerve deficit. A subtle middle ear lesion was observed on otoscopy and computed tomographic images demonstrated an osseous middle ear tumor. Complete surgical excision resulted in the partial recovery of facial nerve function. Facial nerve dysfunction is rarely caused by middle ear tumors. The weakness is typically due to a compressive effect on the middle ear portion of the facial nerve. Early recognition is crucial since removal of these lesions may lead to the recuperation of facial nerve function.

  15. Redefinition of the helical rim in cauliflower-ear surgery.

    PubMed

    Schonauer, F; La Rusca, I; Pereira, J A; Molea, G

    2002-01-01

    Cauliflower ear is a serious deformity of the auricle induced by single or repeated injury to the external ear. Few papers deal with surgical techniques for correcting this deformity. We describe the use of ipsilateral excess cartilage to restore the helical rim. Copyright 2002 The British Association of Plastic Surgeons.

  16. Modified suture-bridge technique to prevent a marginal dog-ear deformity improves structural integrity after rotator cuff repair.

    PubMed

    Ryu, Keun Jung; Kim, Bang Hyun; Lee, Yohan; Lee, Yoon Seok; Kim, Jae Hwa

    2015-03-01

    The arthroscopic suture-bridge technique has proved to provide biomechanically firm fixation of the torn rotator cuff to the tuberosity by increasing the footprint contact area and pressure. However, a marginal dog-ear deformity is encountered not infrequently when this technique is used, impeding full restoration of the torn cuff. To evaluate the structural and functional outcomes of the use of a modified suture-bridge technique to prevent a marginal dog-ear deformity compared with a conventional suture-bridge method in rotator cuff repair. Cohort study; Level of evidence 2. A consecutive series of 71 patients aged 50 to 65 years who underwent arthroscopic rotator cuff repair for full-thickness medium-sized to massive tears was evaluated. Patients were divided into 2 groups according to repair technique: a conventional suture-bridge technique (34 patients; group A) versus a modified suture-bridge technique to prevent a marginal dog-ear deformity (37 patients; group B). Radiographic evaluations included postoperative cuff integrity using MRI. Functional evaluations included pre- and postoperative range of motion (ROM), pain visual analog scale (VAS), the University of California, Los Angeles (UCLA) shoulder rating scale, the Constant score, and the American Shoulder and Elbow Surgeons (ASES) score. All patients were followed up clinically at a minimum of 1 year. When the 2 surgical techniques were compared, postoperative structural integrity by Sugaya classification showed the distribution of types I:II:III:IV:V to be 4:20:2:4:4 in group A and 20:12:4:0:1 in group B. More subjects in group B had a favorable Sugaya type compared with group A (P < .001). The postoperative healed:retear rate was 26:8 in group A and 36:1 in group B, with a significantly lower retear rate in group B (P = .011). However, there were no significant differences in ROM and all functional outcome scores between the 2 groups postoperatively. When surgical techniques were compared across healed

  17. [Constricted ear therapy with free auricular composite grafts].

    PubMed

    Liu, Tun; Zhang, Lian-sheng; Zhuang, Hong-xing; Zhang, Ke-yuan

    2004-03-01

    A simple and effective therapy for single side constricted ear. Transplanting normal side free composite auricular grafts to constricted ear (15 patients and 15 sides), then lengthening the helix, exposing the scapha, correcting deformity. The 15 patients composite grafts all survived. The helix has been lengthened, the scapha exposed, the normal ear reduced, the constricted ear augmented and two sides ear have become symmetry. This method is simple and results are satisfied.

  18. A different type of 'glue ear': report of an unusual case of prominent ears.

    PubMed

    Purcell, Elizabeth M; O'Neill, Ann C; Regan, Padraic J

    2003-09-01

    Prominent ears is a condition that can cause extreme psychological distress in young people. This cosmetic deformity can be corrected by otoplasty, an outpatient surgical procedure that is associated with a high rate of patient satisfaction. We report the unusual case of a teenage boy who had repeatedly applied cyanoacrylate adhesive ("superglue") to his postauricular skin in an attempt to pin back his prominent ears. This case of "glue ear" was ultimately resolved by successful otoplasty, although the residual effects of the glue resulted in delayed healing of the surgical wound.

  19. Two flaps and Z-plasty technique for correction of longitudinal ear lobe cleft.

    PubMed

    Lee, Paik-Kwon; Ju, Hong-Sil; Rhie, Jong-Won; Ahn, Sang-Tae

    2005-06-01

    Various surgical techniques have been reported for the correction of congenital ear lobe deformities. Our method, the two-flaps-and-Z-plasty technique, for correcting the longitudinal ear lobe cleft is presented. This technique is simple and easy to perform. It enables us to keep the bulkiness of the ear lobe with minimal tissue sacrifice, and to make a shorter operation scar. The small Z-plasty at the free ear lobe margin avoids notching deformity and makes the shape of the ear lobe smoother. The result is satisfactory in terms of matching the contralateral normal ear lobe in shape and symmetry.

  20. Complications of ear rings.

    PubMed

    Lane, Jennifer C E; O'Toole, Gregory

    2012-06-01

    In this paper the complications of ear piercing are considered and the treatment of resultant deformities is described. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. The newborn butterfly project: a shortened treatment protocol for ear molding.

    PubMed

    Doft, Melissa A; Goodkind, Alison B; Diamond, Shawn; DiPace, Jennifer I; Kacker, Ashutosh; LaBruna, Anthony N

    2015-03-01

    Secondary to circulating maternal estrogens, a baby's ear cartilage is unusually plastic during the first few weeks of life, providing an opportunity to correct ear deformities by molding. If molding is initiated during the first days of life with a more rigid molding system than previously described in the literature, the authors hypothesized that treatment time would be reduced and the correction rate would increase. An interdisciplinary team identified and assessed all infants born with ear deformities at New York-Presbyterian Hospital/Weill Cornell Medical Center. The authors conducted a prospective, institutional review board-approved study on the first consecutive 100 infants identified. Parents were surveyed initially, immediately after treatment, and at 6 and 12 months. One hundred fifty-eight ears in 96 patients underwent ear molding using the EarWell Infant Ear Correction System. Eighty-two percent of the children had the device placed in the newborn nursery and 95 percent had it placed before 2 weeks of life. Average treatment time was 14 days, and 96 percent of the deformities were corrected. Complications were limited to mild pressure ulcerations. Ninety-nine percent of parents stated that they would have the procedure repeated. The molding period can be reduced from 6 to 8 weeks to 2 weeks by initiating molding during the first weeks of life and using a more secure and rigid device. Through an interdisciplinary approach, the authors were able to identify patients and to correct the deformity earlier and faster than has been previously published, eliminating the need for surgical correction in many children. Therapeutic, IV.

  2. A New Approach for the Correction of Prominent Ear Deformity: The Distally Based Perichondrio-Adipo-Dermal Flap Technique.

    PubMed

    Cihandide, Ercan; Kayiran, Oguz; Aydin, Elif Eren; Uzunismail, Adnan

    2016-06-01

    Otoplasty techniques are generally divided into 2 categories as cartilage-cutting and cartilage-sparing. The cartilage-cutting techniques have been criticized because of their high risk of hematoma, skin necrosis, and ear deformity. As a result, suture-based cartilage-sparing methods like Mustardé and Furnas-type suture techniques have become increasingly popular. However, with these techniques postauricular suture extrusion may be seen and recurrence rates of up to 25% have been reported. In this study, cartilage-sparing otoplasty is redefined by introduction of the distally based perichondrio-adipo-dermal flap which is elevated from the postauricular region. Thirty-seven ears (17 bilateral and 3 unilateral) in 20 patients (14 females and 6 males) have been operated with the defined technique by the same surgeon. The distally based perichondrio-adipo-dermal flap is advanced posteriorly to correct the deformity, also acting as a strong postauricular support to prevent recurrence. In addition to the resultant natural-looking antihelical fold, the posterior advancement of the flap corrects both the otherwise wide conchoscaphal and conchomastoid angles. The operative technique is explained in detail with results and the literature is reviewed. There were no hematomas. After an average follow-up of 8.3 months (2-16 months), recurrence was seen in only 1 patient who requested no further surgery. No patients developed suture extrusion or granuloma. The authors introduce a simple and safe procedure to correct prominent ears with benefits including a resultant natural-looking antihelical fold and less tissue trauma. The distally based perichondrio-adipo-dermal flap seems to prevent suture extrusion and may also help to reduce recurrence rates. By forming neochondrogenesis which is stimulated by elevation of the perichondrium, this flap gives the promise of longer durability of the newly formed antihelical fold.

  3. Management of auricular hematoma and the cauliflower ear.

    PubMed

    Greywoode, Jewel D; Pribitkin, Edmund A; Krein, Howard

    2010-12-01

    Acute auricular hematoma is common after blunt trauma to the side of the head. A network of vessels provides a rich blood supply to the ear, and the ear cartilage receives its nutrients from the overlying perichondrium. Prompt management of hematoma includes drainage and prevention of reaccumulation. If left untreated, an auricular hematoma can result in complications such as perichondritis, infection, and necrosis. Cauliflower ear may result from long-standing loss of blood supply to the ear cartilage and formation of neocartilage from disrupted perichondrium. Management of cauliflower ear involves excision of deformed cartilage and reshaping of the auricle. © Thieme Medical Publishers.

  4. [SOX10 mutation is relevant to inner ear malformation in patients with Waardenburg syndrome].

    PubMed

    Xu, G Y; Hao, Q Q; Zhong, L L; Ren, W; Yan, Y; Liu, R Y; Li, J N; Guo, W W; Zhao, H; Yang, S M

    2016-11-07

    Objective: To determine the relevance between the SOX 10 mutation and Waardenburg syndrome (WS) accompanied with inner ear abnormality by analyzing the inner ear imaging results and molecular and genetic results of the WS patients with the SOX 10 mutation. Methods: This study included 36 WS in patients during 2001 and 2015 in the department of otorhinolaryngology head and neck surgery, Chinese Peoples's Liberation Army General Hospital. The condition of the inner ear of each patient was assessed by analyzing HRCT scans of the temporal bone and MRI scans of the brain and internal auditory canal. Meanwhile, the possible pathogenic genes of WS, including SOX10, MITF , and PAX 3, were also screened. Patients were divided into two groups according to SOX 10 mutation.The Fisher accuracy test was used to determine statistical difference of inner ear deformation incidence between the two groups. Results: Among all 36 patients, 12 were found to have inner ear abnormality. Most abnormalities were posterior semicircular canal deformations, some accompanied with cochlear deformation and an enlarged vestibule. Among all patients, 9 patients were SOX 10 heterozygous mutation carriers, among which six showed bilateral inner ear abnormality. Fisher accuracy test results suggested a significant correlation between the SOX 10 mutation and inner ear abnormality in WS patients ( P =0.036). Conclusion: This study found that WS patients with the SOX 10 mutation are more likely to have deformed inner ears when compared to WS patients without the SOX 10 mutation.

  5. Remodelling of the pinna in myxoid degeneration of the ear.

    PubMed

    Kean, J; Stewart, K J

    2010-07-01

    Idiopathic deformation of the pinna is not widely reported in the current literature. We present a series of cases in which patients have required surgery for spontaneous thickening and deformation of the auricular cartilage, and a description of a technique for surgical correction. Four cases of idiopathic deformation of the pinna are reported. Our preferred technique of scaphoid rim incision and anterior carving of the cartilage is described, with intra-operative photographs. Each patient reported spontaneous swelling of the upper poles of the ears beginning in the second or third decade of life. In 3 cases the deformity was bilateral, although in each of these cases one side was more severely affected than the other. Histology for these cases was reported as myxoid degeneration of the ear. All of the reported patients were pleased with the aesthetic outcome of their auricular remodelling. Currently, there are no typical patient demographics for idiopathic myxoid degeneration of the ear. We have achieved good aesthetic results by hand carving the anterior aspect of the deformed cartilage via scaphoid rim incisions. Copyright 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Milestones in the History of Ear Reconstruction.

    PubMed

    Berghaus, Alexander; Nicoló, Marion San

    2015-12-01

    The reconstruction of ear deformities has been challenging plastic surgeons since centuries. However, it is only in the 19th century that reports on partial and total ear reconstruction start increasing. In the quest for an aesthetically pleasing and natural-looking result, surgeons worked on the perfect framework and skin coverage. Different materials and flap techniques have evolved. Some were abandoned out of frustration, while others kept evolving over the years. In this article, we discuss the milestones in ear reconstruction-from ancient times to early attempts in Western civilization to the key chapters of ear reconstruction in the 20th century leading to the current techniques. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. A new method for correcting type I and type II constricted (cup and lop) ears.

    PubMed

    Xiaogeng, Hu; Hongxing, Zhuang; Qinghua, Yang; Haiyue, Jiang; Yanyong, Zhao

    2006-01-01

    Tanzer suggested the term "constricted ear," denoting a spectrum of deformities limited to the superior third of the ear. Tanzer classified the constricted ear into three types. Type I ears have involvement of the helix, which usually is flattened. Type II ears show involvement of both the helix and the scapha. With type III ears, the auricle is rolled into a nearly tubular form that some authors regard as a form of microtia. The authors' new method for correcting the constricted ear varies in accordance with the diverse degree of deformity. The new method was used to correct constricted ears through a one-stage operation in eight type I cases. For the remaining six type 2 cases, the methods were combined with composite grafting. Most of the patients were satisfied with the final results. Therefore, the authors conclude that their approach is suitable for the treatment of type I and type II constricted ears.

  8. Piercing the upper ear: a simple infection, a difficult reconstruction.

    PubMed

    Cicchetti, S; Skillman, J; Gault, D T

    2002-04-01

    Piercing the upper ear to retain jewellery is now commonplace. When infection ensues, devastating chondritis leads to collapse of the ear. To our knowledge, the surgical reconstruction of post-piercing deformities has not been documented in the literature. We present five such cases referred for autogenous-tissue ear reconstruction. In four of these, the destroyed segments of ear cartilage were replaced with a carved costal-cartilage framework. One patient declined surgery. The importance of preventing infection is stressed. Copyright 2002 The British Association of Plastic Surgeons.

  9. Finite element modeling of acousto-mechanical coupling in the cat middle ear

    PubMed Central

    Tuck-Lee, James P.; Pinsky, Peter M.; Steele, Charles R.; Puria, Sunil

    2008-01-01

    The function of the middle ear is to transfer acoustic energy from the ear canal to the cochlea. An essential component of this system is the tympanic membrane. In this paper, a new finite element model of the middle ear of the domestic cat is presented, generated in part from cadaver anatomy via microcomputed tomographic imaging. This model includes a layered composite model of the eardrum, fully coupled with the acoustics in the ear canal and middle-ear cavities. Obtaining the frequency response from 100 Hz to 20 kHz is a computationally challenging task, which has been accomplished by using a new adaptive implementation of the reduced-order matrix Padé-via-Lanczos algorithm. The results are compared to established physiological data. The fully coupled model is applied to study the role of the collagen fiber sublayers of the eardrum and to investigate the relationship between the structure of the middle-ear cavities and its function. Three applications of this model are presented, demonstrating the shift in the middle-ear resonance due to the presence of the septum that divides the middle-ear cavity space, the significance of the radial fiber layer on high frequency transmission, and the importance of the transverse shear modulus in the eardrum microstructure. PMID:18646982

  10. Klippel-Feil syndrome and associated ear anomalies.

    PubMed

    Yildirim, Nadir; Arslanoğlu, Atilla; Mahiroğullari, Mahir; Sahan, Murat; Ozkan, Hüseyin

    2008-01-01

    Klippel-Feil syndrome (KFS) is a congenital segmentation anomaly of the cervical vertebrae that manifests as short neck, low hair line, and limited neck mobility. Various systemic malformations may also accompany the syndrome including wide variety of otopathologies affecting all 3 compartments of the ear (external, middle, and inner ear) as well as internal acoustic canal and vestibular aqueduct. We aimed to investigate these involvements and their clinical correlates in a group of patients with KFS. We present 20 KFS cases, of which 12 (% 60) displayed most of the reported ear abnormalities such as microtia, external ear canal stenosis, chronic ear inflammations and their sequels, anomalies of the tympanic cavity and ossicles, inner ear dysplasies, deformed internal acoustic canal, and wide vestibular aqueduct, which are demonstrated using the methods of otoscopy, audiologic testing, and temporal bone computed tomography. This series represents one of the highest reported rate of ear involvement in KFS. We found no correlation between the identified ear pathologies and the skeletal and extraskeletal malformations. The genetic nature of the syndrome was supported by the existence of affected family members in 4 (20%) of the cases.

  11. Non-surgical Management of Congenital Auricular Deformities.

    PubMed

    Mohammadi, Ali Akbar; Imani, Mohammad Taghi; Kardeh, Sina; Karami, Mehrab Mohammad; Kherad, Masoomeh

    2016-05-01

    Unlike congenital auricular malformations which are identified by underdevelopment of dermal and cartilaginous tissues, deformed ears are less sever congenital anomalies characterized only by a misshaped pinna structure and can be improved with acceptable cosmetic results and minimal cost through ear molding if treated in early neonatal period. In this study, authors present the first report of using splinting techniques for treatment of deformational auricular anomalies in Iranian children. Our case load consisted of a series of 29 patients (Male=16, Female=13) who were referred to Plastic Surgery Unit of Shiraz University of Medical Sciences from September 2011 to December 2014. Children aged more than 6 moths were excluded. Twenty-nine children affected by various deformities including prominent ears (n=11), lop ears (n=8) and constricted ears (n=10) were treated by splintage as a nonsurgical technique. The mean time of treatment was 13.33±2 weeks. Eight (27.6%) patients did not complete the treatment. Splinting resulted in excellent or satisfactory results in 12 (57.14%) of treated cases. No improvement was observed at the end of the molding treatment in 9 patients. No complication was observed during the treatment in any of the patients. The nonsurgical molding can be used as an effective approach for achieving natural outcomes and correcting cosmetic abnormalities. Rate of satisfaction is dependent on type of deformity, the neonatal age in which treatment started and also parents' adherence to treatment methods and principals. Concerning the low rate of complications and high satisfactory results the method can be used instead of surgery in appropriate cases.

  12. Prominent ears and their correction: a forty-year experience.

    PubMed

    Georgiade, G S; Riefkohl, R; Georgiade, N G

    1995-01-01

    The technique described in this article correcting the protruding ear deformity has evolved over 40 years. The original procedures and our subsequent modifications are described, including 20-year followup results. The possible pitfalls in carrying out this procedure and how to avoid them are also described. A relatively standardized short procedure with minimal morbidity and maximum long-term results yields an aesthetically satisfactory looking ear.

  13. Design of a dynamic sensor inspired by bat ears

    NASA Astrophysics Data System (ADS)

    Müller, Rolf; Pannala, Mittu; Reddy, O. Praveen K.; Meymand, Sajjad Z.

    2012-09-01

    In bats, the outer ear shapes act as beamforming baffles that create a spatial sensitivity pattern for the reception of the biosonar signals. Whereas technical receivers for wave-based signals usually have rigid geometries, the outer ears of some bat species, such as horseshoe bats, can undergo non-rigid deformations as a result of muscular actuation. It is hypothesized that these deformations provide the animals with a mechanism to adapt their spatial hearing sensitivity on short, sub-second time scales. This biological approach could be of interest to engineering as an inspiration for the design of beamforming devices that combine flexibility with parsimonious implementation. To explore this possibility, a biomimetic dynamic baffle was designed based on a simple shape overall geometry based on an average bat ear. This shape was augmented with three different biomimetic local shape features, a ridge on its exposed surface as well as a flap and an incision along its rim. Dynamic non-rigid deformations of the shape were accomplished through a simple actuation mechanism based on linear actuation inserted at a single point. Despite its simplicity, the prototype device was able to reproduce the dynamic functional characteristics that have been predicted for its biological paragon in a qualitative fashion.

  14. Computed tomographic findings in 205 dogs with clinical signs compatible with middle ear disease: a retrospective study.

    PubMed

    Belmudes, Audrey; Pressanti, Charline; Barthez, Paul Y; Castilla-Castaño, Eloy; Fabries, Lionel; Cadiergues, Marie C

    2018-02-01

    Computed tomography (CT) is considered to be the reference method to evaluate middle ear structures. To evaluate the presence and severity of CT changes in the middle ear and establish if any specific clinical presentations are associated with otitis media. Medical records of animals referred for CT with history and clinical signs consistent with middle ear disease. Retrospective evaluation of CT examinations of tympanic bullae performed over a six year period. Medical records were reviewed for signalment, clinical signs and cytological evaluation of the external ear canal. Dogs were divided into three clinical groups: chronic otitis externa (Group 1), peripheral vestibular disorder (Group 2) and other clinical presentations (Group 3). Group 1 - Of 214 ears, 87 (40.7%) had CT abnormalities: 38 of 87 (17.7%) had material-filled bullae, 42 of 87 (19.6%) had thickened bullae walls and seven of 87 (3.2%) had lysis of the bulla. Abnormalities were significantly more frequent in dogs with suppurative otitis than in erythemato-ceruminous otitis (57% and 23%, respectively; P = 0.003). Proliferative otitis, particularly in French bulldogs, was associated with severe otitis media. Group 2 - Of the 106 ears, 91 (85.8%) had normal tympanic bullae. Group 3 - Of the 26 ears from deaf dogs, 17 had filled bullae; all nine affected dogs were Cavalier King Charles spaniels. All dogs with Claude Bernard Horner syndrome or head tilt had normal tympanic bullae. CT is useful for canine chronic otitis externa, particularly in suppurative or proliferative otitis, even in the absence of associated neurological signs. © 2017 ESVD and ACVD.

  15. Design of composite scaffolds and three-dimensional shape analysis for tissue-engineered ear

    PubMed Central

    Cervantes, Thomas M.; Bassett, Erik K.; Tseng, Alan; Kimura, Anya; Roscioli, Nick; Randolph, Mark A.; Vacanti, Joseph P.; Hadlock, Theresa A.; Gupta, Rajiv; Pomerantseva, Irina; Sundback, Cathryn A.

    2013-01-01

    Engineered cartilage is a promising option for auricular reconstruction. We have previously demonstrated that a titanium wire framework within a composite collagen ear-shaped scaffold helped to maintain the gross dimensions of the engineered ear after implantation, resisting the deformation forces encountered during neocartilage maturation and wound healing. The ear geometry was redesigned to achieve a more accurate aesthetic result when implanted subcutaneously in a nude rat model. A non-invasive method was developed to assess size and shape changes of the engineered ear in three dimensions. Computer models of the titanium framework were obtained from CT scans before and after implantation. Several parameters were measured including the overall length, width and depth, the minimum intrahelical distance and overall curvature values for each beam section within the framework. Local curvature values were measured to gain understanding of the bending forces experienced by the framework structure in situ. Length and width changed by less than 2%, whereas the depth decreased by approximately 8% and the minimum intrahelical distance changed by approximately 12%. Overall curvature changes identified regions most susceptible to deformation. Eighty-nine per cent of local curvature measurements experienced a bending moment less than 50 µN-m owing to deformation forces during implantation. These quantitative shape analysis results have identified opportunities to improve shape fidelity of engineered ear constructs. PMID:23904585

  16. Design of composite scaffolds and three-dimensional shape analysis for tissue-engineered ear.

    PubMed

    Cervantes, Thomas M; Bassett, Erik K; Tseng, Alan; Kimura, Anya; Roscioli, Nick; Randolph, Mark A; Vacanti, Joseph P; Hadlock, Theresa A; Gupta, Rajiv; Pomerantseva, Irina; Sundback, Cathryn A

    2013-10-06

    Engineered cartilage is a promising option for auricular reconstruction. We have previously demonstrated that a titanium wire framework within a composite collagen ear-shaped scaffold helped to maintain the gross dimensions of the engineered ear after implantation, resisting the deformation forces encountered during neocartilage maturation and wound healing. The ear geometry was redesigned to achieve a more accurate aesthetic result when implanted subcutaneously in a nude rat model. A non-invasive method was developed to assess size and shape changes of the engineered ear in three dimensions. Computer models of the titanium framework were obtained from CT scans before and after implantation. Several parameters were measured including the overall length, width and depth, the minimum intrahelical distance and overall curvature values for each beam section within the framework. Local curvature values were measured to gain understanding of the bending forces experienced by the framework structure in situ. Length and width changed by less than 2%, whereas the depth decreased by approximately 8% and the minimum intrahelical distance changed by approximately 12%. Overall curvature changes identified regions most susceptible to deformation. Eighty-nine per cent of local curvature measurements experienced a bending moment less than 50 µN-m owing to deformation forces during implantation. These quantitative shape analysis results have identified opportunities to improve shape fidelity of engineered ear constructs.

  17. Preventing Cauliflower Ear With a Modified Tie-Through Technique.

    PubMed

    Dimeff, R J; Hough, D O

    1989-03-01

    In brief: Hematoma following trauma to the external ear is a common problem among wrestlers and boxers. If the hematoma is not treated promptly, infection, fibrosis, scarring, and calcification may develop, leading to the gross deformity known as cauliflower ear or wrestler's ear. Evacuation of the hematoma followed by compression of the auricle is commonly regarded as the treatment of choice. However, fluid frequently reaccumulates after this procedure. The authors describe a tie-through suture technique in which a collodion packing is secured to the auricle with two buttons. Multiple treatments for fluid reaccumulation are rarely necessary when this technique is used.

  18. Non-surgical Management of Congenital Auricular Deformities

    PubMed Central

    Mohammadi, Ali Akbar; Imani, Mohammad Taghi; Kardeh, Sina; Karami, Mehrab Mohammad; Kherad, Masoomeh

    2016-01-01

    BACKGROUND Unlike congenital auricular malformations which are identified by underdevelopment of dermal and cartilaginous tissues, deformed ears are less sever congenital anomalies characterized only by a misshaped pinna structure and can be improved with acceptable cosmetic results and minimal cost through ear molding if treated in early neonatal period. In this study, authors present the first report of using splinting techniques for treatment of deformational auricular anomalies in Iranian children. METHODS Our case load consisted of a series of 29 patients (Male=16, Female=13) who were referred to Plastic Surgery Unit of Shiraz University of Medical Sciences from September 2011 to December 2014. Children aged more than 6 moths were excluded. Twenty-nine children affected by various deformities including prominent ears (n=11), lop ears (n=8) and constricted ears (n=10) were treated by splintage as a nonsurgical technique. The mean time of treatment was 13.33±2 weeks. RESULTS Eight (27.6%) patients did not complete the treatment. Splinting resulted in excellent or satisfactory results in 12 (57.14%) of treated cases. No improvement was observed at the end of the molding treatment in 9 patients. No complication was observed during the treatment in any of the patients. CONCLUSION The nonsurgical molding can be used as an effective approach for achieving natural outcomes and correcting cosmetic abnormalities. Rate of satisfaction is dependent on type of deformity, the neonatal age in which treatment started and also parents’ adherence to treatment methods and principals. Concerning the low rate of complications and high satisfactory results the method can be used instead of surgery in appropriate cases. PMID:27579269

  19. Technical innovations in ear reconstruction using a skin expander with autogenous cartilage grafts.

    PubMed

    Dashan, Yu; Haiyue, Jiang; Qinghua, Yang; Bo, Pan; Lin, Lin; Tailing, Wang; Yanmei, Wang; Xiao, Qin; Hongxing, Zhuang

    2008-01-01

    Pioneers such as Tanzer and Brent have established the foundations of microtia reconstruction using an autogenous costal cartilage framework. The framework and its skin coverage are the two limiting factors in ear reconstruction. At the present time autogenous rib cartilage and mastoid skin are still first choice materials for most surgeons. They have the combined advantages of well-matched texture and colour. To reconstruct a symmetrical, accurate, prominent auricle and minimise as much as possible the chest wall deformity caused by rib cartilage harvesting, we set out to improve our techniques for cartilaginous framework definition and to use the remnant ear to enhance the projection of the reconstructed ear. Since 2000, 342 cases (366 ears) were treated using our current techniques. Data pertaining to complications were recorded. Final results were assessed a minimum of 1 year postoperatively. The follow-up period ranged from 1 to 6 years. Most of the patients with microtia were satisfied with the results of their ear reconstruction. In conclusion, our techniques help to reduce the quantity of rib cartilage needed to fabricate ear framework and minimise chest wall deformity. The frameworks are accurate, prominent and stable. Reconstructed ears are similar in colour and appearance to the normal side. Our innovations are practical and reliable for microtia reconstruction using skin expanders in combination with a sculpted autogenous rib cartilage framework.

  20. Malformations of the middle and inner ear on CT imaging in 22q11 deletion syndrome.

    PubMed

    Loos, Elke; Verhaert, Nicolas; Willaert, Annelore; Devriendt, Koenraad; Swillen, Ann; Hermans, Robert; Op de Beeck, Katya; Hens, Greet

    2016-11-01

    The 22q11 deletion syndrome (22q11DS), the most frequent microdeletion syndrome in humans, presents with a large variety of abnormalities. A common abnormality is hearing impairment. The exact pathophysiological explanation of the observed hearing loss remains largely unknown. The aim of this study was to analyze the middle and inner ear malformations as seen on computer tomographic imaging in patients with 22q11DS. We retrospectively reviewed the charts of 11 22q11DS patients who had undergone a CT of the temporal bone in the past. Of the 22 examined ears, two showed an abnormal malleus and incus, 10 presented with a dense stapes superstructure, and three ears had an abnormal orientation of the stapes. With regard to the inner ear, 12 ears showed an incomplete partition type II with a normal vestibular aqueduct. In four ears the vestibule and lateral semicircular canal were composed of a single cavity, in 14 ears the vestibule was too wide, and three ears had a broadened lateral semicircular canal. These findings suggest that malformations of the stapes, cochlea, vestibule, and lateral semicircular canal are frequent in 22q11DS. To our knowledge, the current study involves the largest case series describing middle and inner ear malformations in 22q11DS. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  1. Cauliflower ear - a minimally invasive treatment method in a wrestling athlete: a case report.

    PubMed

    Haik, Josef; Givol, Or; Kornhaber, Rachel; Cleary, Michelle; Ofir, Hagit; Harats, Moti

    2018-01-01

    Acute auricular hematoma can be caused by direct blunt trauma or other injury to the external ear. It is typically seen in those who practice full contact sports such as boxing, wrestling, and rugby. "Cauliflower ear" deformity, fibrocartilage formation during scarring, is a common complication of auricular hematomas. Therefore, acute drainage of the hematoma and postprocedural techniques for preventing recurrence are necessary for preventing the deformity. There are many techniques although no superior method of treatment has been found. In this case report, we describe a novel method using needle aspiration followed by the application of a magnet and an adapted disc to the affected area of the auricular. This minimally invasive, simple, and accessible method could potentially facilitate the treatment of cauliflower ear among full contact sports athletes.

  2. Inner ear anomalies and conductive hearing loss in children with Apert syndrome: an overlooked otologic aspect.

    PubMed

    Zhou, Guangwei; Schwartz, Lynn Thomas; Gopen, Quinton

    2009-02-01

    To identify the occurrence of inner ear structural anomalies and conductive hearing loss (CHL) in children with Apert syndrome. Retrospective review. Pediatric tertiary referral center. Twenty pediatric patients with Apert syndrome were found; all patients (38/40 ears) had inner ear anomalies. Computerized tomography of the head/temporal bone, pure-tone (including air and bone conduction) audiometry, and tympanometry. Imaging demonstrating inner ear anomalies, including malformations of the cochlea, dilated vestibule, and/or semicircular canal; audiologic findings of air-bone gap(s). Hearing loss was found in 90% of the patients with Apert syndrome, and 80% of them had CHL. Air-bone gaps were found at all frequencies, with larger gaps at low frequencies. Fifty percent (20/40) of the ears had better than 0 dB hearing level bone conduction thresholds at 250 and/or 500 Hz. Normal middle ear pressure and mobility were found in all ears with intact eardrum. Inner ear anomalies were found in all patients, and 90% of them had bilateral involvement. Most frequently observed inner ear anomalies were dilated vestibule, malformed lateral semicircular canal, and cochlear dysplasia. Children with Apert syndrome may present with significant CHL that cannot be explained by minor middle ear pathologies alone. This conductive loss may be, at least partially, attributed to the inner ear anomalies; however, these structural anomalies are usually not recognized in these patients. Failure to close air-bone gap after surgical intervention may raise the suspicion of inner ear anomalies, and computed tomographic scan of the temporal bone can provide definitive proof.

  3. Correcting prominent ears with the island technique.

    PubMed

    DeMoura, L F

    1977-01-01

    A surgical procedure is described which corrects the ansiform ear by repositioning and reconstructing the anthelix and the anterior crus with the formation of the triangular fossa. This corrects the scaphoconchal angle and improves the cephaloauricular angle, overcoming the problem of prominent ears. Correction in early childhood is recommended in order to avoid personality problems that may result from the deformity, particularly in boys. The technique employed yields important advantages: (1) prolonged use of the helmet-type of surgical dressing is unnecessary; (2) scars are less conspicuous; (3) the outcome is attractive and normal; (4) bleeding and inflammatory complications are avoided; and (5) recurrence of the malformation is unlikely.

  4. Question mark ears, temporo-mandibular joint malformation and hypotonia: auriculo-condylar syndrome or a distinct entity?

    PubMed

    Priolo, M; Lerone, M; Rosaia, L; Calcagno, E P; Sadeghi, A K; Ghezzi, F; Ravazzolo, R; Silengo, M

    2000-10-01

    We report a boy with prominent, peculiarly malformed ears, abnormality of the ramus of the mandible and hypotonia. An isolated peculiar bilateral ear deformity named 'question mark ear' has been delineated in plastic reconstruction surgery reviews [Cosman et al., 1970 Plast Reconstr Surg 46:454-457; Cosman (1984) Plast Reconstr Surg 73:572-576; Takato et al. (1989) Ann Plast Surg 22:69-73; Brodovsky (1997) Plast Reconstr Surg 100:1254-1257; Park (1998) Plast Reconstr Surg 101:1620-1623; Al-Quattan (1998) Plast Reconstr Surg 102:439-441] and a similar deformity of the ear and changes in the temporo-mandibular joint and condyle has been described by Jampol et al. [(1998) Am J Med Genet 75:449-452] and by Guion-Almeida et al. [(1999) Am J Med Genet 86:130-133]. The present case may be the third description of this malformation complex with additional clinical features characterized by hypotonia and mild developmental delay, or possibly a new distinct entity.

  5. COMPARISON BETWEEN COMPUTED TOMOGRAPHIC CHARACTERISTICS OF THE MIDDLE EAR IN NONBRACHYCEPHALIC AND BRACHYCEPHALIC DOGS WITH OBSTRUCTIVE AIRWAY SYNDROME.

    PubMed

    Salgüero, Raquel; Herrtage, Michael; Holmes, Mark; Mannion, Paddy; Ladlow, Jane

    2016-01-01

    Prevalence of subclinical middle ear lesions in dogs that undergo computed tomography (CT) and magnetic resonance imaging of the head has been reported up to 41%. A predisposition in brachycephalics has been suggested, however evidence-based studies are lacking. Aims of this retrospective cross-sectional study were to compare CT characteristics of the middle ear in groups of nonbrachycephalic and brachycephalic dogs that underwent CT of the head for conditions unrelated to ear disease, and test associations between thickness of the soft palate and presence of subclinical middle ear lesions. One observer recorded CT findings for each dog without knowledge of group status. A total of 65 dogs met inclusion criteria (25 brachycephalic, 40 nonbrachycephalic). Brachycephalic dogs had a significantly thicker bulla wall (P = 2.38 × 10(-26)) and smaller luminal volume (P = 5.74 × 10(-20)), when compared to nonbrachycephalic dogs. Soft palate thickness was significantly greater in the brachycephalic group (P = 2.76 × 10(-9)). Nine of 25 brachycephalic dogs had material in the lumen of the tympanic cavity, compared to zero of 45 of nonbrachycephalics. Within the brachycephalic group, a significant difference in mean soft palate thickness was identified for dogs with material in the middle ear (12.2 mm) vs. air-filled bullae (9 mm; P = 0.016). Findings from the current study supported previous theories that brachycephalic dogs have a greater prevalence of subclinical middle ear effusion and smaller bulla luminal size than nonbrachycephalic dogs. Authors recommend that the bulla lumen volume formula previously developed for mesaticephalic dogs, (-0.612 + 0.757 [lnBW]) be adjusted to 1/3(-0.612 + 0.757 [lnBW]) for brachycephalic breeds. © 2016 American College of Veterinary Radiology.

  6. Pinnaplasty: reshaping ears to improve hearing aid retention.

    PubMed

    Gault, David; Grob, Marion; Odili, Joy

    2007-01-01

    The hearing aid is extremely important to the deaf. A small number have difficulty in retaining the device because the ear is prominent or cup-shaped. This report describes 11 children whose ear shape was modified to improve hearing aid retention and one adult in whom an over set back ear was released to allow fitment of a postaural device. In eight of the 11 children treated, conservative measures such as double-sided tape and retention bands (Huggies) had been tried previously without success. The creation of an antihelical fold in a misshapen ear lacking such a fold provides a reinforcing strut which is useful to support a hearing aid. In patients whose ear had been excessively tethered by previous surgery, projection was restored by inserting a cartilage block behind the ear. In one child with ears tethered by previous surgery, costal cartilage was used not only to release both ears, but also to reconstruct a new helical rim on one side. Surgery enabled a normal postaural hearing aid to be worn in 17 of the 19 ears treated. The two failures deserve special mention. In one patient with a unilateral deformity and severe mental retardation, the dressings were pulled off immediately after surgery. In another patient with a bilateral problem, the appearance and hearing aid retention was improved, but there was not enough room in the postauricular sulcus on one side for the battery component to fit comfortably and an in-the-ear device is now used on that side. Pinnaplasty is a helpful strategy to improve hearing aid retention. Care must be taken not to overdo the set back so that enough room is left to retain the hearing device.

  7. Sex Differences in Patients With CAM Deformities With Femoroacetabular Impingement: 3-Dimensional Computed Tomographic Quantification.

    PubMed

    Yanke, Adam B; Khair, M Michael; Stanley, Robert; Walton, David; Lee, Simon; Bush-Joseph, Charles A; Espinoza Orías, Alejandro; Espinosa Orias, Alejandro A; Inoue, Nozomu; Nho, Shane J

    2015-12-01

    To determine if significant differences exist between male and female CAM deformities using quantitative 3-dimensional (3D) volume and location analysis. Retrospective analysis of preoperative computed tomographic (CT) scans for 138 femurs (69 from male patients and 69 from female patients) diagnosed with impingement from November 2009 to November 2011 was completed. Those patients who presented with hip complaints and had a history, physical examination (limited range of motion, positive impingement signs), plain radiographs (anteroposterior pelvis, 90° Dunn view, false profile view), and magnetic resonance images consistent with femoroacetabular impingement (FAI) and in whom a minimum of 6 months of conservative therapy (oral anti-inflammatory agents, physical therapy, and activity modification) had failed were indicated for arthroscopic surgery and had a preoperative CT scan. Scans were segmented, converted to point cloud data, and analyzed with a custom-written computer program. Analysis included mean CAM height and volume, head radius, and femoral version. Differences were analyzed using an unpaired t test with significance set at P < .05. Female patients had greater femoral anteversion compared with male patients (female patients, 15.5° ± 8.3°; male patients, 11.3° ± 9.0°; P = .06). Male femoral head radii were significantly larger than female femoral heads (female patients, 22.0 ± 1.3 mm; male patients, 25.4 ± 1.3 mm; P < .001). Male CAM height was significantly larger than that in female patients (female patients, 0.66 ± 0.61 mm; male patients, 1.51 ± 0.75 mm; P < .001). Male CAM volume was significantly larger as well (male patients, 433 ± 471 mm(3); female patients, 89 ± 124 mm(3); P < .001). These differences persisted after normalizing height (P < .001) and volume (P < .001) to femoral head radius. Average clock face distribution was from the 1:09 o'clock position ± the 2:51 o'clock position to the 3:28 o'clock position ± the 1:59 o

  8. Maintaining ear aesthetics in helical rim reconstruction.

    PubMed

    Taylor, James M; Rajan, Ruchika; Dickson, John K; Mahajan, Ajay L

    2014-03-01

    Wedge resections of the helical rim may result in a significant deformity of the ear with the ear not only smaller but cupped and prominent too. Our technique involves resection of the wedge in the scaphal area without extending into the concha followed by advancement of the helical rim into the defect. This technique is most suitable for peripheral defects of the helical rim, in the middle third. Our modified surgical technique was applied to reconstruction of the pinna after resection of the tumor in 12 patients. Free cartilaginous helical rim, length of helical rim to be resected, and projection of the ear from the mastoid was measured. This was then compared with measurements after the operation, and the patient satisfaction assessed with a visual analog scale. The free cartilaginous rim was 91.67 ± 5.61 mm. Of this, 21.92 ± 3.78 mm was resected, which amounted to 23.84% ± 3.35% of the rim. Although this resulted in a mean increase in ear projection of 6.42 ± 1.68 mm, the aesthetic outcome was good (visual analog scale, 9.08 ± 0.9). This technique reduces cupping and does not make the ear as prominent as it may do after a conventional wedge resection and results in high patient satisfaction.

  9. Skull deformations in craniosynostosis and endocrine disorders: morphological and tomographic analysis of the skull from the crypt of the Silesian Piasts in Brzeg (16th-17th century), Poland.

    PubMed

    Kozłowski, T; Cybulska, M; Błaszczyk, B; Krajewska, M; Jeśman, C

    2014-10-01

    of morphological and tomographic (CT) studies of the skull that was found in the crypt of the Silesian Piasts in the St. Jadwiga church in Brzeg (Silesia, Poland) are presented and discussed here. The established date of burial of probably a 20-30 years old male was 16th-17th century. The analyzed skull showed premature obliteration of the major skull sutures. It resulted in the braincase deformation, similar to the forms found in oxycephaly and microcephaly. Tomographic analysis revealed gross pathology. Signs of increased intracranial pressure, basilar invagination and hypoplasia of the occipital bone were observed. Those results suggested the occurrence of the very rare Arnold-Chiari syndrome. Lesions found in the sella turcica indicated the development of pituitary macroadenoma, which resulted in the occurrence of discreet features of acromegaly in the facial bones. The studied skull was characterized by a significantly smaller size of the neurocranium (horizontal circumference 471 mm, cranial capacity ∼ 1080 ml) and strongly expressed brachycephaly (cranial index=86.3), while its height remained within the range for non-deformed skulls. A narrow face, high eye-sockets and prognathism were also observed. Signs of alveolar process hypertrophy with rotation and displacement of the teeth were noted. The skull showed significant morphological differences compared to both normal and other pathological skulls such as those with pituitary gigantism, scaphocephaly and microcephaly. Copyright © 2014 Elsevier GmbH. All rights reserved.

  10. Tumbling cartilage flap and free auricular composite tissue transplantation for correcting mild and moderate forms of constricted ear.

    PubMed

    Pan, Bo; Zhao, Yanyong; Zhuang, Hongxing; Lin, Lin; Liu, Lei; Jiang, Haiyue

    2010-01-01

    To report a new surgical approach that results in a natural size and contour of the external malformed constricted ear. A total of 62 consecutive patients with constricted ear underwent surgery between July 1, 2005, and December 31, 2007. Depending on the features and severity of the deformity, the methods of tumbling cartilage flap (CF), free auricular composite graft, or a combination of these 2 techniques were applied. A total of 45 patients were treated with the method of tumbling CF. Twelve were treated with an auricular composite graft from the contralateral ear, and in 5 patients a combination of the 2 methods was used. In all cases, there was an improvement in the size, shape, and symmetry of the ears, and most patients were satisfied with the outcome. Complications were rare, and there was no donor site deformity. The technique of tumbling CF and free auricular composite graft provides a simple and promising treatment for constricted ears. Furthermore, this technique is easy to apply with a predictable good outcome.

  11. Tomographic particle image velocimetry of desert locust wakes: instantaneous volumes combine to reveal hidden vortex elements and rapid wake deformation

    PubMed Central

    Bomphrey, Richard J.; Henningsson, Per; Michaelis, Dirk; Hollis, David

    2012-01-01

    Aerodynamic structures generated by animals in flight are unstable and complex. Recent progress in quantitative flow visualization has advanced our understanding of animal aerodynamics, but measurements have hitherto been limited to flow velocities at a plane through the wake. We applied an emergent, high-speed, volumetric fluid imaging technique (tomographic particle image velocimetry) to examine segments of the wake of desert locusts, capturing fully three-dimensional instantaneous flow fields. We used those flow fields to characterize the aerodynamic footprint in unprecedented detail and revealed previously unseen wake elements that would have gone undetected by two-dimensional or stereo-imaging technology. Vortex iso-surface topographies show the spatio-temporal signature of aerodynamic force generation manifest in the wake of locusts, and expose the extent to which animal wakes can deform, potentially leading to unreliable calculations of lift and thrust when using conventional diagnostic methods. We discuss implications for experimental design and analysis as volumetric flow imaging becomes more widespread. PMID:22977102

  12. Reconstruction of acquired sub-total ear defects with autologous costal cartilage.

    PubMed

    Harris, P A; Ladhani, K; Das-Gupta, R; Gault, D T

    1999-06-01

    Acquired sub-total ear defects are common and challenging to reconstruct. We report the use of an autologous costal cartilage framework to reconstruct sub-total defects involving all anatomical regions of the ear. Twenty-eight partially damaged ears in 27 patients were reconstructed with this technique. The defects resulted from bites (14), road traffic accidents (five), burns (four), iatrogenic causes (four) and chondritis following minor trauma (one). Computerised image analysis revealed a median of 31% (range 13-72%) ear loss. An autologous costal cartilage framework was fashioned in all cases. If adequate local skin was available, this was draped over the framework, but in nine cases preliminary tissue expansion was used and in a further three cases with significant scarring, the framework was covered with a temporoparietal fascial flap. Clinical assessment after ear reconstruction was undertaken, scoring for symmetry, the helical rim, the antihelical fold, the lobe position and a 'natural look' to produce a four-point scale; 11 were excellent, 12 were good, two were fair and three were poor. Our experience suggests that formal delayed reconstruction with autologous costal cartilage is to be recommended when managing acquired, sub-total ear deformity.

  13. Transcartilaginous ear piercing and infectious complications: a systematic review and critical analysis of outcomes.

    PubMed

    Sosin, Michael; Weissler, Jason M; Pulcrano, Marisa; Rodriguez, Eduardo D

    2015-08-01

    The purpose of this systematic review was to critically analyze infectious complications and treatment following transcartilaginous ear piercing. MEDLINE Pubmed database. A MEDLINE PubMed database search using free text, including "ear chondritis," "ear perichondritis," "ear cartilage piercing," and "auricle piercing," yielded 483 titles. Based on set inclusion and exclusion criteria, the titles, abstracts, and full text articles were reviewed for inclusion and underwent data extraction. Pooled outcomes are reported. A total of 29 articles met inclusion criteria, including 66 patients. The mean age of the patients was 18.7 ± 7.6 years (range: 11-49), 87.5% female. Ear deformity was more likely to occur following postpiercing perichondritis of the scapha 100% versus the helix 43% (P = 0.003). Mean duration of symptoms prior to patients seeking medical attention was 6.1 ± 4.1 days. Greater than 5 days of symptoms prior to seeking treatment was significantly more likely to result in hospitalization. Pseudomonas aeruginosa accounted for 87.2% infections. Of the patients with Pseudomonas, 92.3% were hospitalized versus 75% of the patients infected with Staphylococcus aureus. Initial oral antibiotics prescribed did not target the cultured bacterium in 53.3% of cases; of these, 87.5% were hospitalized. Transcartilaginous postpiercing infection may lead to ear deformity and hospitalization. Patients (customers) and practitioners must be aware of optimal treatment strategies to minimize associated morbidity. Scapha piercing and delay in presentation are associated with poorer outcomes. Pseudomonas is the most common bacterial infection. Initial antibiotic selection must be optimized accordingly. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  14. The pathogenesis of cauliflower ear. An experimental study in rabbits.

    PubMed

    Ohlsén, L; Skoog, T; Sohn, S A

    1975-01-01

    Appreciating an imcomplete understanding of the pathogenesis of cauliflower ear, an experimental study was designed to demonstrate the pathophysiology of this deformity. The investigation was conducted in 2-month-old rabbits. In one ear a collection of blood was placed under the raised perichondrium which was then sutured back in place and the skin closed. In the other ear an equal amount of blood was deposited between the intact perichondrium and skin. In the first study new cartilage developed under the perichondrium, but in the ear in which the blood was left above the surface of the perichondrium-covered cartilage, complete resorption of the clot occurred. The cauliflower ear was thus shown to be generating cartilage, arising from a layer of raised perichondrium which was further stimulated by a sero-sanguinous medium. The subperichondrial hematoma was extensively invaded by chondroblasts within 2 weeks, and over a period of 4 weeks the new tissue gradually changed into more mature cartilage. It was a consistent finding that the separated perichondrium retracted, thus causing the original cartilage to rise and buckle over the hamatoma, similar to the picture observed in the human pathology.

  15. Ear Infection (Middle Ear)

    MedlinePlus

    ... secretions from the middle ear Swelling, inflammation and mucus in the eustachian tubes from an upper respiratory ... your baby for at least six months. Breast milk contains antibodies that may offer protection from ear ...

  16. Stahl ear correction using the third crus cartilage flap.

    PubMed

    Gundeslioglu, A Ozlem; Ince, Bilsev

    2013-12-01

    Stahl ear is usually associated with the existence of a third crus that traverses the scapha. The absence of the superior crus of the antihelix, a broadened scapha, and unfolded, long helical rim may contribute to the formation of the deformity. The method presented in this article is a combined technique intended to recreate the absent superior crus using the third crus as a cartilage flap along with elimination of the third crus, reducing the scapha size, and correcting helical rim deformities by skin and cartilage excisions. One bilateral and three unilateral cases were operated on with this technique (five auricles). The first unilateral cases were performed without scapha reduction and helix correction which was used in the other three cases with successful results. This procedure can be used to correct Stahl ear variations in the case of an absent superior crus when a third crus is present, the scapha is of increased size, and the helix is long without a fold. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  17. A simplified method for correcting Tanzer's group II constricted ears: Construction of the superior crus as a strut with cartilage expansion grafting.

    PubMed

    Kim, Young Soo; Chung, Seum

    2016-04-01

    A constricted ear, also known as a cup ear or lop ear, is a deformity characterized by curling of the upper portion of the ear, including the helix, scapha, and antihelix. In Tanzer's classification, group II constricted ears have deformities involving the helix and the scapha. Although partial or total absence of the superior crus of the antihelix has been noted in group II constricted ears, most plastic surgeons have corrected group II constricted ears using the expansion technique and skin flaps, without formation of the superior crus. However, the expansion technique does not always yield satisfactory results in group II constricted ears. Between May 2011 and April 2014, the authors operated on 21 patients with group II constricted ears using the technique described in this study. The follow-up period ranged from 2 months to 2 years. In our procedure for correcting group II constricted ears, we focused on restoring the superior crus of the antihelix. As a strong superior crus acts as a strut in the upper third of the ear, it supports the helical rim and creates the scapha. Eventually, the newly formed superior crus enables the helical rim to expand in the upper third of the constricted ear. In this article, we present our method of correcting group II constricted ears, in which the superior crus is constructed as a strut and cartilage expansion grafts are used. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. New optical tomographic & topographic techniques for biomedical applications

    NASA Astrophysics Data System (ADS)

    Buytaert, Jan

    The mammalian middle ear contains the eardrum and the three auditory ossicles, and forms an impedance match between sound in air and pressure waves in the fluid of the inner ear. Without this intermediate system, with its unsurpassed efficiency and dynamic range, we would be practically deaf. Physics-based modeling of this extremely complex mechanical system is necessary to help our basic understanding of the functioning of hearing. Highly realistic models will make it possible to predict the outcome of surgical interventions and to optimize design of ossicle prostheses and active middle ear implants. To obtain such models and with realistic output, basic input data is still missing. In this dissertation I developed and used two new optical techniques to obtain two essential sets of data: accurate three-dimensional morphology of the middle ear structures, and elasticity parameters of the eardrum. The first technique is a new method for optical tomography of macroscopic biomedical objects, which makes it possible to measure the three-dimensional geometry of the middle ear ossicles and soft tissues which are connecting and suspending them. I made a new and high-resolution version of this orthogonal-plane fluorescence optical sectioning method, to obtain micrometer resolution in macroscopic specimens. The result is thus a complete 3-D model of the middle (and inner) ear of gerbil in unprecedented quality. On top of high-resolution morphological models of the middle ear structures, I applied the technique in other fields of research as well. The second device works according to a new optical profilometry technique which allows to measure shape and deformations of the eardrum and other membranes or objects. The approach is called projection moire profilometry, and creates moire interference fringes which contain the height information. I developed a setup which uses liquid crystal panels for grid projection and optical demodulation. Hence no moving parts are present and

  19. Crystallographic texture and earing behavior analysis for different second cold reductions of double-reduction tinplate

    NASA Astrophysics Data System (ADS)

    Liao, Lu-hai; Zheng, Xiao-fei; Kang, Yong-lin; Liu, Wei; Yan, Yan; Mo, Zhi-ying

    2018-06-01

    Since the production of tinplate with non-earing properties is difficult, especially when it is produced via the double-reduction process, the optimal degree of second cold reduction is particularly important for achieving desirable drawing properties. The evolution of texture and the earing propensity of double-reduction tinplate with different extents of second reduction were investigated in this study. Optical microscopy and scanning electron microscopy were used to observe the changes in the microstructure at various extents of reduction. Two common testing methods, X-ray diffraction (XRD) and electron backscatter diffraction, were used to investigate the texture of the specimens, which revealed the effects of deformation percentage on the final texture development and the change in the grain boundary. The earing rate was determined via earing tests involving measurement of the height of any ear. The results obtained from both XRD analyses and earing tests revealed the same ideal value for the second cold reduction on the basis of the relationship between crystallographic texture and the degree of earing.

  20. Inner ear anatomy in Waardenburg syndrome: radiological assessment and comparison with normative data.

    PubMed

    Kontorinis, Georgios; Goetz, Friedrich; Lanfermann, Heinrich; Luytenski, Stefan; Giesemann, Anja M

    2014-08-01

    As patients with Waardenburg syndrome (WS) represent potential candidates for cochlear implantation, their inner ear anatomy is of high significance. There is an ongoing debate whether WS is related to any inner ear dysplasias. Our objective was to evaluate radiologically the inner ear anatomy in patients with WS and identify any temporal bone malformations. A retrospective case review was carried out in a tertiary, referral center. The high resolution computed tomography (HRCT) scans of the temporal bone from 20 patients (40 ears) with WS who were managed for deafness in a tertiary referral center from 1995 to 2012 were retrospectively examined. Measurements of 15 different inner ear dimensions, involving the cochlea, the vestibule, the semicircular canals and the internal auditory meatus, as well as measurements of the vestibular aqueduct, were performed independently by two neuroradiologists. Finally, we compared the results from the WS group with a control group consisting of 50 normal hearing subjects (100 ears) and with previously reported normative values. Inner ear malformations were not found in any of the patients with WS. All measured inner ear dimensions were within the normative values compiled by our study group as well as by others. Inner ear malformations are not characteristic for all types of WS; however, certain rare subtypes might be related to inner ear deformities. Normative cochleovestibular dimensions that can help in assessing the temporal bone anatomy are provided. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. Ear discharge

    MedlinePlus

    ... swabs or other small objects into the ear Middle ear infection Other causes of ear discharge include: Eczema ... tube surgery - what to ask your doctor Images Ear anatomy Eardrum repair - series References Bauer CA, Jenkins HA. Otologic symptoms and syndromes. In: Flint PW, Haughey BH, Lund V, et ...

  2. Low dose tomographic fluoroscopy: 4D intervention guidance with running prior

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flach, Barbara; Kuntz, Jan; Brehm, Marcus

    Purpose: Today's standard imaging technique in interventional radiology is the single- or biplane x-ray fluoroscopy which delivers 2D projection images as a function of time (2D+T). This state-of-the-art technology, however, suffers from its projective nature and is limited by the superposition of the patient's anatomy. Temporally resolved tomographic volumes (3D+T) would significantly improve the visualization of complex structures. A continuous tomographic data acquisition, if carried out with today's technology, would yield an excessive patient dose. Recently the authors proposed a method that enables tomographic fluoroscopy at the same dose level as projective fluoroscopy which means that if scanning time ofmore » an intervention guided by projective fluoroscopy is the same as that of an intervention guided by tomographic fluoroscopy, almost the same dose is administered to the patient. The purpose of this work is to extend authors' previous work and allow for patient motion during the intervention.Methods: The authors propose the running prior technique for adaptation of a prior image. This adaptation is realized by a combination of registration and projection replacement. In a first step the prior is deformed to the current position via affine and deformable registration. Then the information from outdated projections is replaced by newly acquired projections using forward and backprojection steps. The thus adapted volume is the running prior. The proposed method is validated by simulated as well as measured data. To investigate motion during intervention a moving head phantom was simulated. Real in vivo data of a pig are acquired by a prototype CT system consisting of a flat detector and a continuously rotating clinical gantry.Results: With the running prior technique it is possible to correct for motion without additional dose. For an application in intervention guidance both steps of the running prior technique, registration and replacement, are

  3. Ear wax

    MedlinePlus

    See your provider if your ears are blocked with wax and you are unable to remove the wax. Also call if you have an ear wax blockage and you develop new symptoms, such as: Drainage from the ear Ear pain Fever Hearing loss that continues after you clean the wax

  4. Saddle-nose and bilateral cauliflower ear deformities with pyoderma gangrenosum-like ulcers, cavitary pulmonary lesions, digital gangrene and pulselessness in a young female.

    PubMed

    Subhadarshani, Sweta; Gupta, Vishal; Chahal, Anurag; Verma, Kaushal K

    2017-06-15

    We report a young female who presented with saddle-nose and bilateral cauliflower ear deformities along with pyoderma gangrenosum-like ulcers, digital gangrene and pulselessness. Subsequently, she was found to have bilateral conductive hearing loss, a corneal opacity, mild aortic regurgitation and radiological evidence of cavitary changes in lungs and aortoarteritis. Our patient had a constellation of symptoms which posed a diagnostic challenge. Finally, a diagnosis of relapsing polychondritis with several unusual features was made. Overlap with Takayasu's arteritis and granulomatosis with polyangitis, which has been reported rarely in the literature, cannot be excluded. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Cauliflower ear – a minimally invasive treatment method in a wrestling athlete: a case report

    PubMed Central

    Haik, Josef; Givol, Or; Kornhaber, Rachel; Cleary, Michelle; Ofir, Hagit; Harats, Moti

    2018-01-01

    Acute auricular hematoma can be caused by direct blunt trauma or other injury to the external ear. It is typically seen in those who practice full contact sports such as boxing, wrestling, and rugby. “Cauliflower ear” deformity, fibrocartilage formation during scarring, is a common complication of auricular hematomas. Therefore, acute drainage of the hematoma and postprocedural techniques for preventing recurrence are necessary for preventing the deformity. There are many techniques although no superior method of treatment has been found. In this case report, we describe a novel method using needle aspiration followed by the application of a magnet and an adapted disc to the affected area of the auricular. This minimally invasive, simple, and accessible method could potentially facilitate the treatment of cauliflower ear among full contact sports athletes. PMID:29403318

  6. Ear Pieces

    ERIC Educational Resources Information Center

    DiJulio, Betsy

    2011-01-01

    In this article, the author describes an art project wherein students make fanciful connections between art and medicine. This project challenges students to interpret "ear idioms" (e.g. "blow it out your ear," "in one ear and out the other") by relying almost entirely on realistic ear drawings, the placement of them, marks, and values. In that…

  7. Prophylactic Z-plasty - correcting helical rim deformity from wedge excision.

    PubMed

    Kim, Peter

    2010-09-01

    Wedge excision is a popular and well documented surgical method for treating a wide range of skin lesions and cancers of the ear in the general practice setting. In the majority of cases, this is a simple and cosmetically pleasing treatment. However, it may create helical rim deformity. This article describes a simple method of preventing such deformity using prophylactic Z-plasty.

  8. Ear wax

    PubMed Central

    2008-01-01

    Introduction Ear wax only becomes a problem if it causes a hearing impairment or other ear-related symptoms. Ear wax is more likely to accumulate and cause a hearing impairment when normal extrusion is prevented — for example, by the use of hearing aids, or by the use of cotton buds to clean the ears. Ear wax can visually obscure the ear drum, and may need to be removed for diagnostic purposes. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical question: What are the effects of methods to remove ear wax? We searched: Medline, Embase, The Cochrane Library, and other important databases up to June 2007 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found nine systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review, we present information relating to the effectiveness and safety of the following interventions: ear syringing; manual removal (other than ear syringing); and wax softeners (alone or prior to syringing). PMID:19450340

  9. Ear Disorders

    MedlinePlus

    ... most common illness in infants and young children. Tinnitus, a roaring in your ears, can be the ... problems in your inner ear; its symptoms include tinnitus and dizziness. Ear barotrauma is an injury to ...

  10. [Melorheostosis associated with arteriovenous malformation of the ear].

    PubMed

    Ingen-Housz-Oro, S; Chigot, V; Hamel-Teillac, D; Brunelle, F; De Prost, Y

    2001-09-01

    Melorheostosis is a rare bone dystrophy that may be associated with various vascular malformations. We report a case of arteriovenous fistulae of the ear associated with melorheostosis limited to the same side of the body. A 13 year-old boy presented a congenital port-wine nevus of the right side of the head complicated by an arteriovenous fistulae and angiomatous nodules of the ear. He was treated by laser, surgery of the nodules, arterial embolisations and sclerotherapy. In 1999, he had a benign trauma of the right hand. The X-ray showed hyperostosis resembling wax flowing down a candle reaching the carpus and some of the metacarpals and the phalanges of the right hand, typical of melorheostosis. The complete radiographic check-up showed the same characteristic appearance on the right side of the skull and the long bones of the right upper limb. Except a deformation of the right fingers, there were no others symptoms. Melorheostosis is a rare, sporadic and benign bone dysplasia that may be localized to a single limb or disseminated. The diagnosis is usually made in late childhood. Pain, stiffness, deformation of a limb are the main clinical manifestations. The skin may be erythematous and sclerotic. The radiographic appearance is characteristic with hyperostosis on one side of the bone resembling wax flowing down a candle. A vascular abnormality is present in 17 p. 100 of cases (hemangiomas, aneurysms, renal artery stenosis.). In these cases, melorheostosis is usually limited to the same side of the vascular lesion. We report the first case of arteriovenous fistulae of the ear associated with melorheostosis, on the same side of the body. The physiopathology of melorheostosis is still unknown but the association with a homolateral vascular abnormality suggests a localized defect in embryogenesis of the vascular and skeletal systems.

  11. Reconstruction of Moderately Constricted Ears by Combining V-Y Advancement of Helical Root, Conchal Cartilage Graft, and Mastoid Hitch.

    PubMed

    Elshahat, Ahmed; Lashin, Riham

    2016-01-01

    Despite the multitude of corrective procedures described in the literature, adequate surgical correction of the congenital constricted ear remains a challenge. The maintenance of the shape and size of the reconstructed upper neohelix poses a particular problem. In the present study, a total of 12 cases of reconstruction were undertaken. All of them were moderate (type IIA Tanzer classification) deformities. A combined procedure was adopted using a V-Y advancement of the helical root, cartilage scoring, and cartilage grafting from the contralateral concha to reconstruct the upper helix. A mastoid hitch was used as an adjunct to these procedures to maintain helical elevation and prevent recurrence. Mean follow-up period was 6 months. RESULTS were excellent (n = 7), good (n = 4), and fair (n = 1). Paired t test showed a significant increase in the height of the constricted ear postoperatively (P < .001) and a nonsignificant difference between the height of the constricted and contralateral ears postoperatively (P > .05). Apart from dislodgment of the mastoid hitch suture in 1 patient, no complications were recorded. This combined technique is useful in correcting moderately constricted ear deformities.

  12. Swimmer's Ear

    MedlinePlus

    ... Eardrum Taking Care of Your Ears Can Loud Music Hurt My Ears? Your Ears What's Earwax? How Do Pain Relievers Work? View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...

  13. Choristoma of the middle ear: a component of a new syndrome?

    PubMed

    Buckmiller, L M; Brodie, H A; Doyle, K J; Nemzek, W

    2001-05-01

    Salivary choristoma of the middle ear is a rare entity. The authors report the 26th known case, which is unique in several respects: the patient had abnormalities of the first and second branchial arches, as well as the otic capsule and facial nerve in ways not yet reported. Our patient presented with bilateral preauricular pits, conchal bands, an ipsilateral facial palsy, and bilateral Mondini-type deformities. A review of the literature revealed salivary choristomas of the middle ear to be frequently associated with branchial arch abnormalities, most commonly the second, as well as abnormalities of the facial nerve. All 25 cases were reviewed and the results reported with respect to clinical presentation, associated abnormalities, operative findings, and hearing results. It has been proposed that choristoma of the middle ear may represent a component of a syndrome along with unilateral hearing loss, abnormalities of the incus and/or stapes, and anomalies of the facial nerve. Eighty-six percent of the reported patients with choristoma have three or four of the four criteria listed to designate middle ear salivary choristoma as part of a syndrome. In the remaining four patients, all of the structures were not assessed.

  14. Ear Problems

    MedlinePlus

    ... may have OTITIS MEDIA, an infection of the middle ear. Self CareSee your doctor. Many ear infections will ... half-alcohol, half-white vinegar solution in the ear before and after swimming or ... JOINT (TMJ) SYNDROME, a disorder that affects the jaw joint, may ...

  15. Tomographic diagnostics of nonthermal plasmas

    NASA Astrophysics Data System (ADS)

    Denisova, Natalia

    2009-10-01

    In the previous work [1], we discussed a ``technology'' of tomographic method and relations between the tomographic diagnostics in thermal (equilibrium) and nonthermal (nonequilibrium) plasma sources. The conclusion has been made that tomographic reconstruction in thermal plasma sources is the standard procedure at present, which can provide much useful information on the plasma structure and its evolution in time, while the tomographic reconstruction of nonthermal plasma has a great potential at making a contribution to understanding the fundamental problem of substance behavior in strongly nonequilibrium conditions. Using medical terminology, one could say, that tomographic diagnostics of the equilibrium plasma sources studies their ``anatomic'' structure, while reconstruction of the nonequilibrium plasma is similar to the ``physiological'' examination: it is directed to study the physical mechanisms and processes. The present work is focused on nonthermal plasma research. The tomographic diagnostics is directed to study spatial structures formed in the gas discharge plasmas under the influence of electrical and gravitational fields. The ways of plasma ``self-organization'' in changing and extreme conditions are analyzed. The analysis has been made using some examples from our practical tomographic diagnostics of nonthermal plasma sources, such as low-pressure capacitive and inductive discharges. [0pt] [1] Denisova N. Plasma diagnostics using computed tomography method // IEEE Trans. Plasma Sci. 2009 37 4 502.

  16. Computed tomographic morphometry of tympanic bulla shape and position in brachycephalic and mesaticephalic dog breeds.

    PubMed

    Mielke, Ben; Lam, Richard; Ter Haar, Gert

    2017-09-01

    Anatomic variations in skull morphology have been previously described for brachycephalic dogs; however there is little published information on interbreed variations in tympanic bulla morphology. This retrospective observational study aimed to (1) provide detailed descriptions of the computed tomographic (CT) morphology of tympanic bullae in a sample of dogs representing four brachycephalic breeds (Pugs, French Bulldogs, English Bulldog, and Cavalier King Charles Spaniels) versus two mesaticephalic breeds (Labrador retrievers and Jack Russell Terriers); and (2) test associations between tympanic bulla morphology and presence of middle ear effusion. Archived head CT scans for the above dog breeds were retrieved and a single observer measured tympanic bulla shape (width:height ratio), wall thickness, position relative to the temporomandibular joint, and relative volume (volume:body weight ratio). A total of 127 dogs were sampled. Cavalier King Charles Spaniels had significantly flatter tympanic bullae (greater width:height ratios) versus Pugs, English Bulldogs, Labrador retrievers, and Jack Russell terriers. French Bulldogs and Pugs had significantly more overlap between tympanic bullae and temporomandibular joints versus other breeds. All brachycephalic breeds had significantly lower tympanic bulla volume:weight ratios versus Labrador retrievers. Soft tissue attenuating material (middle ear effusion) was present in the middle ear of 48/100 (48%) of brachycephalic breeds, but no significant association was found between tympanic bulla CT measurements and presence of this material. Findings indicated that there are significant interbreed variations in tympanic bulla morphology, however no significant relationship between tympanic bulla morphology and presence of middle ear effusion could be identified. © 2017 American College of Veterinary Radiology.

  17. 3D visualization of middle ear structures

    NASA Astrophysics Data System (ADS)

    Vogel, Uwe; Schmitt, Thomas

    1998-06-01

    The achievement of volume geometry data from middle ear structures and surrounding components performs a necessary supposition for the finite element simulation of the vibrational and transfer characteristics of the ossicular chain. So far those models base on generalized figures and size data from anatomy textbooks or particular manual and one- or two-dimensional distance measurements of single ossicles, mostly obtained by light microscopy, respectively. Therefore the goal of this study is to create a procedure for complete three-dimensional imaging of real middle ear structures (tympanic membrane, ossicles, ligaments) in vitro or even in vivo. The main problems are their microscopic size with relevant structures from 10 micrometer to 5 mm, representing various tissue properties (bone, soft tissue). Additionally, these structures are surrounded by the temporal bone, the most solid bone of the human body. Generally there exist several established diagnostic tools for medical imaging that could be used for geometry data acquisition, e.g., X-ray computed tomography and magnetic resonance imaging. Basically they image different tissue parameters, either bony structures (ossicles), or soft tissue (tympanic membrane, ligaments). But considering this application those standard techniques allow low spatial resolution only, usually in the 0.5 - 1mm range, at least in one spatial direction. Thus particular structures of the middle ear region could even be missed completely because of their spatial location. In vitro there is a way out by collecting three complete data sets, each distinguished by 90 degree rotation of a cube-shaped temporal bone specimen. That allows high-resolution imaging in three orthogonal planes, which essentially supports the three-dimensional interpolation of the unknown elements, starting from the regularly set elements of the cubic grid with an edge extension given by the original two-dimensional matrix. A different approach represents the

  18. Ear Tubes

    MedlinePlus

    ... of the ear drum or eustachian tube, Down Syndrome, cleft palate, and barotrauma (injury to the middle ear caused by a reduction of air pressure, ... specialist) may be warranted if you or your child has experienced repeated ... fluid in the middle ear, barotrauma, or have an anatomic abnormality that ...

  19. A modification of incisionless otoplasty for correcting the prominent ear deformity.

    PubMed

    Haytoglu, Suheyl; Haytoglu, Tahir Gokhan; Yildirim, Ilhami; Arikan, Osman Kursat

    2015-11-01

    This article describes a modification of the incisionless otoplasty. We investigated the complication rates, recurrence risks, and patient satisfaction with this modified procedure. In total, 26 patients (49 ears) complaining of prominent ear were operated on. Auriculocephalic distances were measured at three different levels, pre-operatively, at the end of the surgery, and at 4 weeks and 6 months after surgery to evaluate the efficacy of the technique. Patient satisfaction was evaluated using a visual analog scale and the global aesthetic improvement scale was applied by an independent non-participating plastic surgeon at 6 months after the surgery. The mean loss of medialization was ~1 mm at 4 weeks after surgery and 2 mm at 6 months after surgery for all levels. According to visual analog scale, patient or parent satisfaction increased significantly. The global aesthetic improvement scale rated the patients as 93.9% "improved" and 6.1% as "no change." No rating was "worse." There are many advantages of this technique. The operation is not time-consuming, does not require a dressing, and it can be performed in adults with local anesthesia under office conditions, with no need for hospitalization. After the operation, patients can return to their daily activities immediately. It is associated with a low complication rate and high patient satisfaction. This technique is a good option for otoplasty in patients with isolated, inadequate development of anti-helical ridge, and with soft auricular cartilage.

  20. Sparse 4D TomoSAR imaging in the presence of non-linear deformation

    NASA Astrophysics Data System (ADS)

    Khwaja, Ahmed Shaharyar; ćetin, Müjdat

    2018-04-01

    In this paper, we present a sparse four-dimensional tomographic synthetic aperture radar (4D TomoSAR) imaging scheme that can estimate elevation and linear as well as non-linear seasonal deformation rates of scatterers using the interferometric phase. Unlike existing sparse processing techniques that use fixed dictionaries based on a linear deformation model, we use a variable dictionary for the non-linear deformation in the form of seasonal sinusoidal deformation, in addition to the fixed dictionary for the linear deformation. We estimate the amplitude of the sinusoidal deformation using an optimization method and create the variable dictionary using the estimated amplitude. We show preliminary results using simulated data that demonstrate the soundness of our proposed technique for sparse 4D TomoSAR imaging in the presence of non-linear deformation.

  1. A new treatment for parrot beak deformity of the toe.

    PubMed

    Kurokawa, M; Isshiki, N; Inoue, K

    1994-03-01

    Two cases of congenital parrot beak deformity of the toe were treated by pushing back the nail plate, nailbed, matrix, and proximal skin fold in one piece as a flap. The proximal skin portion of this flap was deepithelialized to facilitate this shift, and thus no dog-ear deformity was produced. The distal skin defect of the pulp was covered by a palmar advancement flap. This method does not require augmentation of the fingertip or toetip and is very useful for correcting parrot beak deformities of the toes.

  2. Microbiomes of the normal middle ear and ears with chronic otitis media.

    PubMed

    Minami, Shujiro B; Mutai, Hideki; Suzuki, Tomoko; Horii, Arata; Oishi, Naoki; Wasano, Koichiro; Katsura, Motoyasu; Tanaka, Fujinobu; Takiguchi, Tetsuya; Fujii, Masato; Kaga, Kimitaka

    2017-10-01

    The aim of this study was to profile and compare the middle ear microbiomes of human subjects with and without chronic otitis media. Prospective multicenter cohort study. All consecutive patients undergoing tympanoplasty surgery for chronic otitis media or ear surgery for conditions other than otitis media were recruited. Sterile swab samples were collected from the middle ear mucosa during surgery. The variable region 4 of the 16S rRNA gene in each sample were amplified using region-specific primers adapted for the Illumina MiSeq sequencer (Illumina, CA, USA)). The sequences were subjected to local blast and classified using Metagenome@KIN (World Fusion, Tokyo, Japan). In total, 155 participants were recruited from seven medical centers. Of these, 88 and 67 had chronic otitis media and normal middle ears, respectively. The most abundant bacterial phyla on the mucosal surfaces of the normal middle ears were Proteobacteria, followed by Actinobacteria, Firmicutes, and Bacteroidetes. The children and adults with normal middle ears differed significantly in terms of middle ear microbiomes. Subjects with chronic otitis media without active inflammation (dry ear) had similar middle ear microbiomes as the normal middle ears group. Subjects with chronic otitis media with active inflammation (wet ear) had a lower prevalence of Proteobacteria and a higher prevalence of Firmicutes than the normal middle ears. The human middle ear is inhabited by more diverse microbial communities than was previously thought. Alteration of the middle ear microbiome may contribute to the pathogenesis of chronic otitis media with active inflammation. 2b. Laryngoscope, 127:E371-E377, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  3. Ear asymmetries in middle-ear, cochlear, and brainstem responses in human infants

    PubMed Central

    Keefe, Douglas H.; Gorga, Michael P.; Jesteadt, Walt; Smith, Lynette M.

    2008-01-01

    In 2004, Sininger and Cone-Wesson examined asymmetries in the signal-to-noise ratio (SNR) of otoacoustic emissions (OAE) in infants, reporting that distortion-product (DP)OAE SNR was larger in the left ear, whereas transient-evoked (TE)OAE SNR was larger in the right. They proposed that cochlear and brainstem asymmetries facilitate development of brain-hemispheric specialization for sound processing. Similarly, in 2006 Sininger and Cone-Wesson described ear asymmetries mainly favoring the right ear in infant auditory brainstem responses (ABRs). The present study analyzed 2640 infant responses to further explore these effects. Ear differences in OAE SNR, signal, and noise were evaluated separately and across frequencies (1.5, 2, 3, and 4 kHz), and ABR asymmetries were compared with cochlear asymmetries. Analyses of ear-canal reflectance and admittance showed that asymmetries in middle-ear functioning did not explain cochlear and brainstem asymmetries. Current results are consistent with earlier studies showing right-ear dominance for TEOAE and ABR. Noise levels were higher in the right ear for OAEs and ABRs, causing ear asymmetries in SNR to differ from those in signal level. No left-ear dominance for DPOAE signal was observed. These results do not support a theory that ear asymmetries in cochlear processing mimic hemispheric brain specialization for auditory processing. PMID:18345839

  4. Efficient control schemes with limited computation complexity for Tomographic AO systems on VLTs and ELTs

    NASA Astrophysics Data System (ADS)

    Petit, C.; Le Louarn, M.; Fusco, T.; Madec, P.-Y.

    2011-09-01

    Various tomographic control solutions have been proposed during the last decades to ensure efficient or even optimal closed-loop correction to tomographic Adaptive Optics (AO) concepts such as Laser Tomographic AO (LTAO), Multi-Conjugate AO (MCAO). The optimal solution, based on Linear Quadratic Gaussian (LQG) approach, as well as suboptimal but efficient solutions such as Pseudo-Open Loop Control (POLC) require multiple Matrix Vector Multiplications (MVM). Disregarding their respective performance, these efficient control solutions thus exhibit strong increase of on-line complexity and their implementation may become difficult in demanding cases. Among them, two cases are of particular interest. First, the system Real-Time Computer architecture and implementation is derived from past or present solutions and does not support multiple MVM. This is the case of the AO Facility which RTC architecture is derived from the SPARTA platform and inherits its simple MVM architecture, which does not fit with LTAO control solutions for instance. Second, considering future systems such as Extremely Large Telescopes, the number of degrees of freedom is twenty to one hundred times bigger than present systems. In these conditions, tomographic control solutions can hardly be used in their standard form and optimized implementation shall be considered. Single MVM tomographic control solutions represent a potential solution, and straightforward solutions such as Virtual Deformable Mirrors have been already proposed for LTAO but with tuning issues. We investigate in this paper the possibility to derive from tomographic control solutions, such as POLC or LQG, simplified control solutions ensuring simple MVM architecture and that could be thus implemented on nowadays systems or future complex systems. We theoretically derive various solutions and analyze their respective performance on various systems thanks to numerical simulation. We discuss the optimization of their performance and

  5. 3D finite element model of the chinchilla ear for characterizing middle ear functions

    PubMed Central

    Wang, Xuelin; Gan, Rong Z.

    2016-01-01

    Chinchilla is a commonly used animal model for research of sound transmission through the ear. Experimental measurements of the middle ear transfer function in chinchillas have shown that the middle ear cavity greatly affects the tympanic membrane (TM) and stapes footplate (FP) displacements. However, there is no finite element (FE) model of the chinchilla ear available in the literature to characterize the middle ear functions with the anatomical features of the chinchilla ear. This paper reports a recently completed 3D FE model of the chinchilla ear based on X-ray micro-computed tomography images of a chinchilla bulla. The model consisted of the ear canal, TM, middle ear ossicles and suspensory ligaments, and the middle ear cavity. Two boundary conditions of the middle ear cavity wall were simulated in the model as the rigid structure and the partially flexible surface, and the acoustic-mechanical coupled analysis was conducted with these two conditions to characterize the middle ear function. The model results were compared with experimental measurements reported in the literature including the TM and FP displacements and the middle ear input admittance in chinchilla ear. An application of this model was presented to identify the acoustic role of the middle ear septa - a unique feature of chinchilla middle ear cavity. This study provides the first 3D FE model of the chinchilla ear for characterizing the middle ear functions through the acoustic-mechanical coupled FE analysis. PMID:26785845

  6. Swimmer's Ear (For Parents)

    MedlinePlus

    ... scratching the ear canal, vigorous ear cleaning with cotton swabs, or putting foreign objects like bobby pins ... Also, never put objects into kids' ears, including cotton-tipped swabs. How Is Swimmer's Ear Treated? Treatment ...

  7. Expansion method in secondary total ear reconstruction for undesirable reconstructed ear.

    PubMed

    Liu, Tun; Hu, Jintian; Zhou, Xu; Zhang, Qingguo

    2014-09-01

    Ear reconstruction by autologous costal cartilage grafting is the most widely applied technique with fewer complications. However, undesirable ear reconstruction brings more problems to plastic surgeons. Some authors resort to free flap or osseointegration technique with prosthetic ear. In this article, we introduce a secondary total ear reconstruction with expanded skin flap method. From July 2010 to April 2012, 7 cases of undesirable ear reconstruction were repaired by tissue expansion method. Procedures including removal of previous cartilage framework, soft tissue expander insertion, and second stage of cartilage framework insertion were performed to each case regarding their local conditions. The follow-up time ranged from 6 months to 2.5 years. All of the cases recovered well with good 3-dimensional forms, symmetrical auriculocephalic angle, and stable fixation. All these evidence showed that this novel expansion method is safe, stable, and less traumatic for secondary total ear reconstruction. With sufficient expanded skin flap and refabricated cartilage framework, lifelike appearance of reconstructed ear could be acquired without causing additional injury.

  8. Middle Ear Infections and Ear Tube Surgery (For Parents)

    MedlinePlus

    ... Infection? Swimmer's Ear Perforated Eardrum Hearing Impairment Swimmer's Ear (External ... All information on KidsHealth® is for educational purposes only. For specific medical advice, diagnoses, and treatment, ...

  9. Elephant ear

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/002867.htm Elephant ear poisoning To use the sharing features on this page, please enable JavaScript. Elephant ear plants are indoor or outdoor plants with ...

  10. Airplane Ear

    MedlinePlus

    ... to severe hearing loss Ringing in your ear (tinnitus) Spinning sensation (vertigo) Vomiting resulting from vertigo Bleeding ... complications may include: Permanent hearing loss Ongoing (chronic) tinnitus Prevention Follow these tips to avoid airplane ear: ...

  11. Your Ears

    MedlinePlus

    ... Protect your hearing by wearing earplugs at loud music concerts and around noisy machinery, like in wood ... More on this topic for: Kids Can Loud Music Hurt My Ears? What Is an Ear Infection? ...

  12. Ear examination

    MedlinePlus

    ... ear anatomy Otoscopic exam of the ear References King EF, Couch ME. History, physical examination, and the ... commercial use must be authorized in writing by ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer ...

  13. Inner ear disorders.

    PubMed

    Smouha, Eric

    2013-01-01

    To present a framework for the diagnosis and treatment of inner ear disorders, with an emphasis on problems common to neuro-rehabilitation. Disorders of the inner ear can cause hearing loss, tinnitus, vertigo and imbalance. Hearing loss can be conductive, sensorineural, or mixed; conductive hearing loss arises from the ear canal or middle ear, while sensorineural hearing loss arises from the inner ear or auditory nerve. Vertigo is a hallucination of motion, and is the cardinal symptom of vestibular system disease. It should be differentiated from other causes of dizziness: gait imbalance, disequilibrium, lightheadedness (pre-syncope). Vertigo can be caused by problems in the inner ear or central nervous system. The diagnosis of inner ear disorders begins with a targeted physical examination. The initial work-up of hearing loss is made by audiometry, and vertigo by electronystagmography (ENG). Supplemental tests and MRI are obtained when clinically indicated. The clinical pattern and duration of vertigo are the most important clinical features in the diagnosis. Common inner ear causes of vertigo include: vestibular neuritis (sudden, unilateral vestibular loss), Meniere's disease (episodic vertigo), benign paroxysmal positional vertigo (BPPV), and bilateral vestibular loss. Common central nervous system causes of vertigo include: post concussion syndrome, cervical vertigo, vestibular migraine, cerebrovascular disease, and acoustic neuroma. A basic knowledge of vestibular physiology, coupled with a understanding of common vestibular syndromes, will lead to correct diagnosis and treatment in most cases.

  14. Clamshell tomograph

    DOEpatents

    Derenzo, Stephen E.; Budinger, Thomas F.

    1984-01-01

    In brief, the invention is a tomograph modified to be in a clamshell configuration so that the ring or rings may be moved to multiple sampling positions. The tomograph includes an array of detectors arranged in successive adjacent relative locations along a closed curve in a first position in a selected plane, and means for securing the detectors in the relative locations in a first sampling position. The securing means is movable in the plane in two sections and pivotable at one p The U.S. Government has rights in this invention pursuant to Contract No. W-7405-ENG-48 between the U.S. Department of Energy and the University of California.

  15. Ear Tubes

    MedlinePlus

    ... 1/20th of an inch) that could allow water to enter the middle ear, research studies show no benefit in keeping the ears dry and current guidelines do not recommend routine water precautions. Therefore, you do not need to restrict ...

  16. Active middle ear implant after lateral petrosectomy and radiotherapy for ear cancer.

    PubMed

    Cristalli, Giovanni; Sprinzl, Georg M; Wolf-Magele, Astrid; Marchesi, Paolo; Mercante, Giuseppe; Spriano, Giuseppe

    2014-04-01

    Tumor of the temporal bone is a rare disease with a very poor prognosis. Surgery and postoperative radiotherapy are usually the recommended treatments for squamous cell carcinoma (SCC) of the external and middle ear, which may cause conductive hearing loss. The purpose of this study was to evaluate the audiologic results and compliance of active middle ear implant (AMEI) and establish the feasibility of the procedure in a patient treated for middle ear cancer. A 73-year-old patient treated with lateral petrosectomy, neck dissection, reconstruction/obliteration by pedicled pectoralis major myocutaneous flap, and postoperative full dose radiotherapy for external and middle ear SCC was selected for AMEI. Preoperative audiometric and speech audiometry tests were performed on both ears before and after the activation. Pure tone free field audiometry. Binaural free field speech audiogram. Aided pure tone free field audiometry AMEI results show an increase in air conduction. Speech audiogram showed better discrimination scores in AMEI-aided situations. No complications were observed. AMEI after surgery followed by radiotherapy for middle ear cancer is feasible. Acoustic results in obliterated ear are satisfactory.

  17. Correction of cleft lip nose deformity with rib cartilage.

    PubMed

    Hafezi, Farhad; Naghibzadeh, Bijan; Ashtiani, Abbas Kazemi; Mousavi, S Jaber; Nouhi, Amir Hossein; Naghibzadeh, Ghazal

    2013-07-01

    Correction of cleft lip nasal deformities (CLND) is often unsatisfactory because of problems resulting from cartilage weakness and strong soft tissue forces. Therefore, strong cartilaginous support, such as rib cartilage, is mandatory. The authors describe placement of rib cartilage grafts to create a more symmetric and aesthetically acceptable repair of CLND with improved nasal air flow. Two groups of patients, including those with unilateral and bilateral CLND, underwent operations with different sources of autologous cartilage. Group 1 received grafts from the septum and ear, whereas group 2 received grafts from the septum and ribs. Results were evaluated by 2 independent physicians who rated improvement between pre- and postoperative photographs. There were significant differences in postoperative improvement between patients who received septal/ear cartilage grafts and those who received septal/rib cartilage grafts in both unilateral and bilateral cases (P = .028 and P = .043, respectively). The authors' results demonstrate that rib cartilage has a positive effect on the aesthetic outcome of CLND operations and provides a strong support structure for correcting this deformity with minimal postoperative complications.

  18. The 'WiFi' otoplasty : Combined concentric posterior microchondrectomies and sutures for correction of prominent ears.

    PubMed

    Hendrickx, Benoit I M M; Hamdi, Moustapha; Zeltzer, Assaf; Greensmith, Andrew

    2018-06-01

    Prominent ears are by far the most common congenital ear deformity. Many techniques have been described using one or a combination of 3 basic methods: cartilage cutting, cartilage weakening and pure cartilage shaping techniques. The ideal otoplasty technique should yield a natural correction of the deformity, with low recurrence rates and with little risk of complications. A new cartilage shaping technique using closing wedge concentric microchondrectomies through an entirely posterior approach is presented. Between 2006 and 2017, 200 bilateral otoplasties using this 'WiFi' pattern technique were performed. This technique combined with Mustarde sutures is based on the excision of concentric partial thickness cartilage wedges designed in the pattern of the WiFi symbol. There were no major complications such as anterior skin necrosis and no returns to theatre for infections or haematomas. 3 patients (1.5%) had complete recurrence of the deformity and 10 patients (5%) had to undergo a minor revision for recurrence at the upper pole. 5 patients have had exposure of the end of the permanent upper pole scapho-temporal suture more than 3 months after surgery requiring simple outpatient suture trimming/removal without any recurrence of results. Palpable or bridging sutures were present upon clinical examination in 10 patients (5%) but did not require revision surgery. Here, we describe a fast, safe and reliable technique for otoplasty with no need for extensive dissection, which is applicable to the full range of deformity. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  19. External Otitis (Swimmer's Ear)

    MedlinePlus

    ... Debris removal, antibiotic ear drops, keeping water and cotton swabs out of the ear, and pain relievers ... Injuring the ear canal while cleaning it (using cotton swabs) or getting water or irritants, such as ...

  20. Donor site reconstitution for ear reconstruction.

    PubMed

    Fattah, Adel; Sebire, Neil J; Bulstrode, Neil W

    2010-09-01

    Current techniques of autologous ear reconstruction involve the soft tissue coverage of a carved costal cartilage framework. However, assessment of the morbidity associated with this donor site has been little documented. This study describes a method to reconstruct the defect and analyses the outcomes with or without donor site reconstitution. The donor site was reconstituted by wrapping morcelised cartilage in a vicryl mesh. Twenty-one patients with reconstitution and nine without were recruited to the study. Scar quality and length, dimensions of donor defect and visible deformity were recorded according to a modified Vancouver scar scale. Patients were also assessed by the SF36 questionnaire, a well-validated health survey. In a subset of our study group, we assessed the fate of the donor site reconstitution by direct visualisation in situ and histological analysis. Fifteen donor sites of patients without donor site reconstitution were compared to 23 reconstructed donor sites. In those without, all had a palpable defect with nearly half exhibiting visible chest deformity. In contrast, those that had rib reconstitution did not demonstrate significant chest wall deformity. Intraoperative examination demonstrated formation of a neo-rib, histologically proven to comprise hyaline cartilage admixed with fibrous tissue. Analysis of SF36 results showed a higher satisfaction in the reconstituted group, but in both groups, the donor site was of little overall morbidity. Although there is little difference between the groups in terms of subjectively perceived benefit, rib reconstitution is objectively associated with better costal margin contour and less chest wall deformity. Copyright 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Ear Injuries (For Parents)

    MedlinePlus

    ... Inserting something into the ear. Things like a cotton swab, fingernail, or pencil can scratch the ear ... Never stick anything in their ears — not even cotton swabs or their fingers. Regular bathing should be ...

  2. Chinchilla middle ear transmission matrix model and middle-ear flexibilitya)

    PubMed Central

    Ravicz, Michael E.; Rosowski, John J.

    2017-01-01

    The function of the middle ear (ME) in transforming ME acoustic inputs and outputs (sound pressures and volume velocities) can be described with an acoustic two-port transmission matrix. This description is independent of the load on the ME (cochlea or ear canal) and holds in either direction: forward (from ear canal to cochlea) or reverse (from cochlea to ear canal). A transmission matrix describing ME function in chinchilla, an animal commonly used in auditory research, is presented, computed from measurements of forward ME function: input admittance YTM, ME pressure gain GMEP, ME velocity transfer function HV, and cochlear input admittance YC, in the same set of ears [Ravicz and Rosowski (2012b). J. Acoust. Soc. Am. 132, 2437–2454; (2013a). J. Acoust. Soc. Am. 133, 2208–2223; (2013b). J. Acoust. Soc. Am. 134, 2852–2865]. Unlike previous estimates, these computations require no assumptions about the state of the inner ear, effectiveness of ME manipulations, or measurements of sound transmission in the reverse direction. These element values are generally consistent with physical constraints and the anatomical ME “transformer ratio.” Differences from a previous estimate in chinchilla [Songer and Rosowski (2007). J. Acoust. Soc. Am. 122, 932–942] may be due to a difference in ME flexibility between the two subject groups. PMID:28599566

  3. Chinchilla middle ear transmission matrix model and middle-ear flexibility.

    PubMed

    Ravicz, Michael E; Rosowski, John J

    2017-05-01

    The function of the middle ear (ME) in transforming ME acoustic inputs and outputs (sound pressures and volume velocities) can be described with an acoustic two-port transmission matrix. This description is independent of the load on the ME (cochlea or ear canal) and holds in either direction: forward (from ear canal to cochlea) or reverse (from cochlea to ear canal). A transmission matrix describing ME function in chinchilla, an animal commonly used in auditory research, is presented, computed from measurements of forward ME function: input admittance Y TM , ME pressure gain G MEP , ME velocity transfer function H V , and cochlear input admittance Y C , in the same set of ears [Ravicz and Rosowski (2012b). J. Acoust. Soc. Am. 132, 2437-2454; (2013a). J. Acoust. Soc. Am. 133, 2208-2223; (2013b). J. Acoust. Soc. Am. 134, 2852-2865]. Unlike previous estimates, these computations require no assumptions about the state of the inner ear, effectiveness of ME manipulations, or measurements of sound transmission in the reverse direction. These element values are generally consistent with physical constraints and the anatomical ME "transformer ratio." Differences from a previous estimate in chinchilla [Songer and Rosowski (2007). J. Acoust. Soc. Am. 122, 932-942] may be due to a difference in ME flexibility between the two subject groups.

  4. Taking Care of Your Ears

    MedlinePlus

    ... Audiologist Perforated Eardrum What's Hearing Loss? Can Loud Music Hurt My Ears? What Is an Ear Infection? Swimmer's Ear Your Ears What's Earwax? View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...

  5. Middle Ear Infections (For Parents)

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español Middle Ear Infections KidsHealth / For Parents / Middle Ear Infections What's ... en español Infecciones del oído medio What Are Middle Ear Infections? Ear infections happen when viruses or bacteria ...

  6. Cauliflower ear dissection.

    PubMed

    Fujiwara, Masao; Suzuki, Ayano; Nagata, Takeshi; Fukamizu, Hidekazu

    2011-11-01

    Cauliflower ear (CE) is caused by repeated direct trauma to the external ear. Surgical correction of an established CE is one of the most challenging problems in ear reconstruction. However, no reports have clarified the dissection of an established CE in detail. In this report, the dissection of a CE is described based on macroscopic, microscopic and imaging features. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Estimation of outer-middle ear transmission using DPOAEs and fractional-order modeling of human middle ear

    NASA Astrophysics Data System (ADS)

    Naghibolhosseini, Maryam

    Our ability to hear depends primarily on sound waves traveling through the outer and middle ear toward the inner ear. Hence, the characteristics of the outer and middle ear affect sound transmission to/from the inner ear. The role of the middle and outer ear in sound transmission is particularly important for otoacoustic emissions (OAEs), which are sound signals generated in a healthy cochlea, and recorded by a sensitive microphone placed in the ear canal. OAEs are used to evaluate the health and function of the cochlea; however, they are also affected by outer and middle ear characteristics. To better assess cochlear health using OAEs, it is critical to quantify the impact of the outer and middle ear on sound transmission. The reported research introduces a noninvasive approach to estimate outer-middle ear transmission using distortion product otoacoustic emissions (DPOAEs). In addition, the role of the outer and middle ear on sound transmission was investigated by developing a physical/mathematical model, which employed fractional-order lumped elements to include the viscoelastic characteristics of biological tissues. Impedance estimations from wideband refectance measurements were used for parameter fitting of the model. The model was validated comparing its estimates of the outer-middle ear sound transmission with those given by DPOAEs. The outer-middle ear transmission by the model was defined as the sum of forward and reverse outer-middle ear transmissions. To estimate the reverse transmission by the model, the probe-microphone impedance was calculated through estimating the Thevenin-equivalent circuit of the probe-microphone. The Thevenin-equivalent circuit was calculated using measurements in a number of test cavities. Such modeling enhances our understanding of the roles of different parts of the outer and middle ear and how they work together to determine their function. In addition, the model would be potentially helpful in diagnosing pathologies of

  8. Fusion of MRIs and CT scans for surgical treatment of cholesteatoma of the middle ear in children.

    PubMed

    Plouin-Gaudon, Isabelle; Bossard, Denis; Ayari-Khalfallah, Sonia; Froehlich, Patrick

    2010-09-01

    To evaluate the efficiency of diffusion-weighted magnetic resonance imaging (MRI) and high-resolution computed tomographic (CT) scan coregistration in predicting and adequately locating primary or recurrent cholesteatoma in children. Prospective study. Tertiary care university hospital. Ten patients aged 2 to 17 years (mean age, 8.5 years) with cholesteatoma of the middle ear, some of which were previously treated, were included for follow-up with systematic CT scanning and MRI between 2007 and 2008. Computed tomographic scanning was performed on a Siemens Somaton 128 (0.5/0.2-mm slices reformatted in 0.5/0.3-mm images). Fine cuts were obtained parallel and perpendicular to the lateral semicircular canal in each ear (100 × 100-mm field of view). Magnetic resonance imaging was undertaken on a Siemens Avanto 1.5T unit, with a protocol adapted for young children. Diffusion-weighted imaging was acquired using a single-shot turbo spin-echo mode. To allow for diagnosis and localization of the cholesteatoma, CT and diffusion-weighted MRIs were fused for each case. In 10 children, fusion technique allowed for correct diagnosis and precise localization (hypotympanum, epitympanum, mastoid recess, and attical space) as confirmed by subsequent standard surgery (positive predictive value, 100%). In 3 cases, the surgical approach was adequately determined from the fusion results. Lesion sizes on the CT-MRI fusion corresponded with perioperative findings. Recent developments in imaging techniques have made diffusion-weighted MRI more effective for detecting recurrent cholesteatoma. The major drawback of this technique, however, has been its poor anatomical and spatial discrimination. Fusion imaging using high-resolution CT and diffusion-weighted MRI appears to be a promising technique for both the diagnosis and precise localization of cholesteatomas. It provides useful information for surgical planning and, furthermore, is easy to use in pediatric cases.

  9. Gustatory otalgia and wet ear syndrome: a possible cross-innervation after ear surgery.

    PubMed

    Saito, H

    1999-04-01

    The chorda tympani and Arnold's nerves have close approximation to each other and their cross-innervation is possible after ear surgery. A retrospective study was performed with a temporal bone pathology case and two clinical cases as representatives of such a possibility. Patients had severe otalgia and wet ear during gustatory stimulation. A temporal bone pathology case was studied under a light microscope. Earache and/or wet ear were provoked during gustatory stimulation. Wet ear was tested with iodine-starch reaction after the subject tasted lemon juice. The temporal bone specimen has clusters of regenerated fibers in the tympanic cavity in the area of the chorda tympani and Arnold's nerves, suggesting a possibility of mixing. There are regenerated fibers in the iter chordae anterius, showing successful bridging of the chorda tympani nerves across a long gap. Detachment of the skin over the operated mastoid bowl obscured signs in one clinical case. Another clinical case of gustatory wet ear showed objective evidence of cross-innervation with iodine-starch reaction. The detachment procedure and iodine-starch reaction were the proofs that the signs were related to regenerated fibers. This is the first report of gustatory otalgia and wet ear after ear surgery.

  10. Ear drainage culture

    MedlinePlus

    ... needed. Your health care provider will use a cotton swab to collect the sample from inside the ... Using a cotton swab to take a sample of drainage from the outer ear is not painful. However, ear pain may ...

  11. Ear infection - chronic

    MedlinePlus

    Middle ear infection - chronic; Otitis media - chronic; Chronic otitis media; Chronic ear infection ... Chole RA. Chronic otitis media, mastoiditis, and petrositis. In: Flint PW, Haughey BH, Lund V, et al, eds. Cummings Otolaryngology: Head & Neck Surgery . 6th ed. ...

  12. Chinchilla middle-ear admittance and sound power: High-frequency estimates and effects of inner-ear modifications

    PubMed Central

    Ravicz, Michael E.; Rosowski, John J.

    2012-01-01

    The middle-ear input admittance relates sound power into the middle ear (ME) and sound pressure at the tympanic membrane (TM). ME input admittance was measured in the chinchilla ear canal as part of a larger study of sound power transmission through the ME into the inner ear. The middle ear was open, and the inner ear was intact or modified with small sensors inserted into the vestibule near the cochlear base. A simple model of the chinchilla ear canal, based on ear canal sound pressure measurements at two points along the canal and an assumption of plane-wave propagation, enables reliable estimates of YTM, the ME input admittance at the TM, from the admittance measured relatively far from the TM. YTM appears valid at frequencies as high as 17 kHz, a much higher frequency than previously reported. The real part of YTM decreases with frequency above 2 kHz. Effects of the inner-ear sensors (necessary for inner ear power computation) were small and generally limited to frequencies below 3 kHz. Computed power reflectance was ∼0.1 below 3.5 kHz, lower than with an intact ME below 2.5 kHz, and nearly 1 above 16 kHz. PMID:23039439

  13. Self-ear cleaning practices and the associated risk of ear injuries and ear-related symptoms in a group of university students.

    PubMed

    Khan, Nasim Banu; Thaver, Sivashnee; Govender, Samantha Marlene

    2017-12-31

    Self-ear cleaning is the insertion of objects into the ear canal to clean it, a widespread practice that has the potential to compromise its integrity as a natural, selfcleansing mechanism, and a risk factor for possible injuries. The practice is common among young adults and highest in university than any other graduates. This study aimed to determine the self-ear cleaning practices and associated risk of injury and related symptoms in undergraduate students at KwaZulu-Natal University. The descriptive survey utilized a self-administered questionnaire. Of the 206 participants that responded, 98% engaged in self-ear cleaning, with 75% indicating that it was beneficial. The commonest method (79.6%) being the use of cotton buds, with an associated injury rate of 2.4%. There was no statistically significant associations between those who used or did not use cotton buds and the symptoms experienced. The complications indicate that self-ear cleaning does pose a risk for injury, necessitating more community information and education.

  14. Arteriovenous malformation of the external ear: a clinical assessment with a scoping review of the literature.

    PubMed

    Kim, Shin Hye; Han, Seung Hoon; Song, Yoonjae; Park, Chang Sik; Song, Jae-Jin

    Auricular Arteriovenous Malformation of the external ear is a rarely encountered disease; in particular, arteriovenous malformation arising from the auricle, with spontaneous bleeding, has seldom been reported. In the current study, we report an unusual case of late-onset auricular arteriovenous malformation originating from the posterior auricular artery that was confirmed by computed tomographic angiography. The case was successfully managed by pre-surgical intravascular embolization followed by total lesion excision. Prompted by this case, we also present a scoping review of the literature. A case of a 60 year-old man with right auricular arteriovenous malformation treated in our tertiary care center, and 52 patients with auricular arteriovenous malformation described in 10 case reports and a retrospective review are presented. Auricular arteriovenous malformation can manifest as swelling of the ear, pulsatile tinnitus, pain, and/or bleeding. On physical examination, a pulsatile swelling and/or a tender mass is evident. When arteriovenous malformation is suspected, the lesions should be visualized using imaging modalities that optimally detect vascular lesions, and managed via embolization, mass excision, or auricular resection. Effectiveness of the various diagnostic methods used and the treatment outcomes were analyzed. Various imaging modalities including Doppler sonography, computed tomographic angiography, magnetic resonance angiography, and/or transfemoral cerebral angiography were used to diagnose 38 cases reported in the literature. In another 15 cases, no imaging was performed; treatment was determined solely by physical examination and auscultation. Of the total of 53 cases, 12 were not treated (their symptoms were merely observed) whereas 20 underwent therapeutic embolization. In total, 32 patients, including 1 patient who was not treated and 10 with persistent or aggravated arteriovenous malformation after previous embolization, underwent mass

  15. Theory of forward and reverse middle-ear transmission applied to otoacoustic emissions in infant and adult ears

    PubMed Central

    Keefe, Douglas H.; Abdala, Carolina

    2008-01-01

    The purpose of this study is to understand why otoacoustic emission (OAE) levels are higher in normal-hearing human infants relative to adults. In a previous study, distortion product (DP) OAE input/output (I/O) functions were shown to differ at f2=6 kHz in adults compared to infants through 6 months of age. These DPOAE I/O functions were used to noninvasively assess immaturities in forward/reverse transmission through the ear canal and middle ear [Abdala, C., and Keefe, D. H., (2006). J. Acoust Soc. Am. 120, 3832–3842]. In the present study, ear-canal reflectance and DPOAEs measured in the same ears were analyzed using a scattering-matrix model of forward and reverse transmission in the ear canal, middle ear, and cochlea. Reflectance measurements were sensitive to frequency-dependent effects of ear-canal and middle-ear transmission that differed across OAE type and subject age. Results indicated that DPOAE levels were larger in infants mainly because the reverse middle-ear transmittance level varied with ear-canal area, which differed by more than a factor of 7 between term infants and adults. The forward middle-ear transmittance level was −16 dB less in infants, so that the conductive efficiency was poorer in infants than adults. PMID:17348521

  16. Osteochondroma of the mandibular condyle: a classification system based on computed tomographic appearances.

    PubMed

    Chen, Min-jie; Yang, Chi; Qiu, Ya-ting; Zhou, Qin; Huang, Dong; Shi, Hui-min

    2014-09-01

    The objectives of this study were to introduce the classification of osteochondroma of the mandibular condyle based on computed tomographic images and to present our treatment experiences. From January 2002 and December 2012, a total of 61 patients with condylar osteochondroma were treated in our division. Both clinical and radiologic aspects were reviewed. The average follow-up period was 24.3 months with a range of 6 to 120 months. Two types of condylar osteochondroma were presented: type 1 (protruding expansion) in 50 patients (82.0%) and type 2 (globular expansion) in 11 patients (18.0%). Type 1 condylar osteochondroma presented 5 forms: anterior/anteromedial (58%), posterior/posteromedial (6%), medial (16%), lateral (6%), and gigantic (14%). Local resection was performed on patients with type 1 condylar osteochondroma. Subtotal condylectomy/total condylectomy using costochondral graft reconstruction with/without orthognathic surgeries was performed on patients with type 2 condylar osteochondroma. During the follow-up period, tumor reformation, condyle absorption, and new deformity were not detected. The patients almost reattained facial symmetry. Preoperative classification based on computed tomographic images will help surgeons to choose the suitable surgical procedure to treat the condylar osteochondroma.

  17. Red ear syndrome.

    PubMed

    Purdy, R Allan; Dodick, David W

    2007-08-01

    The red ear syndrome is a rare syndrome originally described by Lance in 1994. It involves pain in and around the ear and associated autonomic phenomena, the most significant of which is cutaneous erythema of the ear ipsilateral to the pain and obvious to the patient and examiner during the attack. It may well represent an auriculo-autonomic cephalgia and/or be part of the group of disorders recognized as trigeminal autonomic cephalalgias. As a syndrome, it still lacks specificity in regard to etiology, mechanisms, and treatment but is important to recognize clinically because of its associations.

  18. Ear tube insertion

    MedlinePlus

    ... eardrum may cause some hearing loss. But most children do not have long-term damage to their hearing or speech, even when the ... not go away with treatment, or if a child has many ear infections ... or that damages nearby nerves Injury to the ear after sudden ...

  19. Psychosocial outcome of patients after ear reconstruction: a retrospective study of 62 patients.

    PubMed

    Horlock, Nigel; Vögelin, Esther; Bradbury, Eileen T; Grobbelaar, Adriaan O; Gault, David T

    2005-05-01

    This was a retrospective study examining the psychosocial morbidity of patients before and after ear reconstruction. Semistructured questionnaires were sent to 90 patents with significant congenital or acquired auricular deformity 2.2 years (range 3 months to 5 years) following autogenous or osteointegrated reconstruction. Sixty-two patients (69%) responded. Twenty-two of the patients below 12 years, who had undergone reconstructive surgery, also completed the Childhood Experience Questionnaire. These were compared with a cohort of 362 normal patients. There was significant psychosocial morbidity in both children and adults with auricular deformity. Seventy-one percent of patients reported reduced self-confidence that affected both social life and leisure activity. Teasing was a prominent symptom in both children (88%) and adults (85%) but was a motivational factor for surgery in children only. Dissatisfaction with the appearance (73.1%), on the other hand, was the main reason for treatment in adults. Following ear reconstruction, 74% of adults and 91% of children reported an improvement in self-confidence resulting in enhanced social life and leisure activities in both adults and children. There was no difference between osteointegrated and autogenous reconstruction. Sixty percent of patients reported their result as excellent. The patients scored their result better than the surgeon. We conclude that auricular reconstruction has significant psychosocial benefit in the majority of children and adults despite donor-site morbidity and a range of technical result.

  20. Expression and function of FGF10 in mammalian inner ear development

    NASA Technical Reports Server (NTRS)

    Pauley, Sarah; Wright, Tracy J.; Pirvola, Ulla; Ornitz, David; Beisel, Kirk; Fritzsch, Bernd

    2003-01-01

    We have investigated the expression of FGF10 during ear development and the effect of an FGF10 null mutation on ear development. Our in situ hybridization data reveal expression of FGF10 in all three canal crista sensory epithelia and the cochlea anlage as well as all sensory neurons at embryonic day 11.5 (E11.5). Older embryos (E18.5) displayed strong graded expression in all sensory epithelia. FGF10 null mutants show complete agenesis of the posterior canal crista and the posterior canal. The posterior canal sensory neurons form initially and project rather normally by E11.5, but they disappear within 2 days. FGF10 null mutants have no posterior canal system at E18.5. In addition, these mutants have deformations of the anterior and horizontal cristae, reduced formation of the anterior and horizontal canals, as well as altered position of the remaining sensory epithelia with respect to the utricle. Hair cells form but some have defects in their cilia formation. No defects were detected in the organ of Corti at the cellular level. Together these data suggest that FGF10 plays a major role in ear morphogenesis. Most of these data are consistent with earlier findings on a null mutation in FGFR2b, one of FGF10's main receptors. Copyright 2003 Wiley-Liss, Inc.

  1. Anomalies of the middle and inner ear.

    PubMed

    Rodriguez, Kimsey; Shah, Rahul K; Kenna, Margaret

    2007-02-01

    The development of the middle and inner ear highlights the intricacy of embryology. As early as 3 weeks after fertilization, the inner ear begins taking form. This process, along with development of the middle ear, continues throughout gestation. At birth, the middle ear, inner ear, and associated structures are almost adult size. An understanding of the embryologic development of the ear serves as a foundation for evaluating and managing congenital malformations of these structures. The focus of this article is the normal, abnormal, and arrested development of the middle and inner ear, with a clinical emphasis on malformed middle and inner ear structures and a discussion of associated syndromes.

  2. Structure and function of the mammalian middle ear. I: Large middle ears in small desert mammals.

    PubMed

    Mason, Matthew J

    2016-02-01

    Many species of small desert mammals are known to have expanded auditory bullae. The ears of gerbils and heteromyids have been well described, but much less is known about the middle ear anatomy of other desert mammals. In this study, the middle ears of three gerbils (Meriones, Desmodillus and Gerbillurus), two jerboas (Jaculus) and two sengis (elephant-shrews: Macroscelides and Elephantulus) were examined and compared, using micro-computed tomography and light microscopy. Middle ear cavity expansion has occurred in members of all three groups, apparently in association with an essentially 'freely mobile' ossicular morphology and the development of bony tubes for the middle ear arteries. Cavity expansion can occur in different ways, resulting in different subcavity patterns even between different species of gerbils. Having enlarged middle ear cavities aids low-frequency audition, and several adaptive advantages of low-frequency hearing to small desert mammals have been proposed. However, while Macroscelides was found here to have middle ear cavities so large that together they exceed brain volume, the bullae of Elephantulus are considerably smaller. Why middle ear cavities are enlarged in some desert species but not others remains unclear, but it may relate to microhabitat. © 2015 Anatomical Society.

  3. [Effect size on resonance of the outer ear canal by simulation of middle ear lesions using a temporal bone preparation].

    PubMed

    Scheinpflug, L; Vorwerk, U; Begall, K

    1995-01-01

    By means of a model of the external and the middle ear it is possible to simulate various, exactly defined pathological conditions of the middle ear and to describe their influence on ear canal resonance. Starting point of the investigations are fresh postmortem preparations of 8 human temporal bones with an intact ear drum and a retained skin of the ear canal. The compliance of the middle ear does not significantly differ from the clinical data of probands with healthy ears. After antrotomy it is possible to simulate pathological conditions of the middle ear one after the other at the same temporal bone. The influence of the changed middle ear conditions on ear drum compliance, ear canal volume and on the resonance curve of the external ear canal was investigated. For example, the middle ear was filled with water to create approximately the same conditions as in acute serous otitis media. In this middle ear condition a significant increase of the sound pressure amplification was found, on an average by 4 decibels compared to the unchanged temporal bone model. A small increase in resonance frequency was also measured. The advantages of this model are the approximately physiological conditions and the constant dimensions of the external and middle ear.

  4. Ear Infections and Language Development.

    ERIC Educational Resources Information Center

    Roberts, Joanne E.; Zeisel, Susan A.

    Ear infections in infants and preschoolers can cause mild or moderate temporary hearing loss, which may in turn affect a child's ability to understand and learn language. Noting that providing children with proper medical treatment for ear infections or middle ear fluid is important in preventing possible problems with language development, this…

  5. Chondro-manubrial deformity and bifid rib, rare variations seen in pectus carinatum: a radiological finding.

    PubMed

    Allwyn Joshua, S; Shetty, Lathika; Pare, V S; Sebastian, Roopa

    2013-07-01

    Pectus carinatum or protrusion deformity of chest wall is less frequently occurring anterior chest wall deformity when compared to pectus excavatum. It may be classified as type 1 or chondro-gladiolar and type 2 or chondro-manubrial deformity. Other variations seen are symmetrical and asymmetrical pectus carinatum. Here we present two unique case reports, one with chondro-manubrial deformity (Currarino-Silverman syndrome) and other with asymmetrical pectus carinatum having bifid rib which are some of the rare variations seen in pectus carinatum found during Computerized tomographic examination. Currarino-Silverman syndrome is a type 2 pectus carinatum, a rare deformity with chondro-manubrial involvement and usually associated congenital heart diseases. Early fusion of sternal plates is one of the known theories in producing this deformity. On the other hand, asymmetrical pectus deformity are usually seen due to imbalance or abnormality in growth plates of costal cartilages leading to forked rib or bifid rib, which are accidently seen on radiological examination. To conclude, our reports would help in differential diagnosis from frequently occurring conditions affecting chest like chondro-gladiolar deformity, pectus excavatum, chest wall tumours, rib fractures and intra thoracic ribs.

  6. Cochlear implantation outcomes in children with common cavity deformity; a retrospective study.

    PubMed

    Zhang, Li; Qiu, Jianxin; Qin, Feifei; Zhong, Mei; Shah, Gyanendra

    2017-09-01

    A common cavity deformity (CCD) is a deformed inner ear in which the cochlea and vestibule are confluent forming a common rudimentary cystic cavity that results in profound hearing loss. There are few studies paying attention to common cavity. Our group is engrossed in observing the improvement of auditory and verbal abilities in children who have received cochlear implantation (CI), and comparing these targets between children with common cavity and normal inner ear structure. A retrospective study was conducted in 12 patients with profound hearing loss that were divided into a common cavity group and a control group, six in each group matched in sex, age and time of implantation, based on inner ear structure. Categories of Auditory Performance (CAP) and speech intelligibility rating (SIR) scores and aided hearing thresholds were collected and compared between the two groups. All patients wore CI for more than 1 year at the Cochlear Center of Anhui Medical University from 2011 to 2015. Postoperative CAP and SIR scores were higher than before operation in both groups (p < 0.05), although the scores were lower in the CCD group than in the control group (p < 0.05). The aided threshold was also lower in the control group than in the CCD group (p < 0.05). Even though audiological improvement in children with CCD was not as good as in those without CCD, CI provides benefits in auditory perception and communication skills in these children.

  7. Swimmer's Ear (External Otitis)

    MedlinePlus

    ... t help, your doctor might prescribe a stronger pain reliever. You'll use this only for a short time — until the ear drops and antibiotics begin to work. To protect your ear while it heals, your ...

  8. Inner Ear Drug Delivery for Auditory Applications

    PubMed Central

    Swan, Erin E. Leary; Mescher, Mark J.; Sewell, William F.; Tao, Sarah L.; Borenstein, Jeffrey T.

    2008-01-01

    Many inner ear disorders cannot be adequately treated by systemic drug delivery. A blood-cochlear barrier exists, similar physiologically to the blood-brain barrier, which limits the concentration and size of molecules able to leave the circulation and gain access to the cells of the inner ear. However, research in novel therapeutics and delivery systems has led to significant progress in the development of local methods of drug delivery to the inner ear. Intratympanic approaches, which deliver therapeutics to the middle ear, rely on permeation through tissue for access to the structures of the inner ear, whereas intracochlear methods are able to directly insert drugs into the inner ear. Innovative drug delivery systems to treat various inner ear ailments such as ototoxicity, sudden sensorineural hearing loss, autoimmune inner ear disease, and for preserving neurons and regenerating sensory cells are being explored. PMID:18848590

  9. Field-portable lensfree tomographic microscope.

    PubMed

    Isikman, Serhan O; Bishara, Waheb; Sikora, Uzair; Yaglidere, Oguzhan; Yeah, John; Ozcan, Aydogan

    2011-07-07

    We present a field-portable lensfree tomographic microscope, which can achieve sectional imaging of a large volume (∼20 mm(3)) on a chip with an axial resolution of <7 μm. In this compact tomographic imaging platform (weighing only ∼110 grams), 24 light-emitting diodes (LEDs) that are each butt-coupled to a fibre-optic waveguide are controlled through a cost-effective micro-processor to sequentially illuminate the sample from different angles to record lensfree holograms of the sample that is placed on the top of a digital sensor array. In order to generate pixel super-resolved (SR) lensfree holograms and hence digitally improve the achievable lateral resolution, multiple sub-pixel shifted holograms are recorded at each illumination angle by electromagnetically actuating the fibre-optic waveguides using compact coils and magnets. These SR projection holograms obtained over an angular range of ±50° are rapidly reconstructed to yield projection images of the sample, which can then be back-projected to compute tomograms of the objects on the sensor-chip. The performance of this compact and light-weight lensfree tomographic microscope is validated by imaging micro-beads of different dimensions as well as a Hymenolepis nana egg, which is an infectious parasitic flatworm. Achieving a decent three-dimensional spatial resolution, this field-portable on-chip optical tomographic microscope might provide a useful toolset for telemedicine and high-throughput imaging applications in resource-poor settings. This journal is © The Royal Society of Chemistry 2011

  10. Field-portable lensfree tomographic microscope†

    PubMed Central

    Isikman, Serhan O.; Bishara, Waheb; Sikora, Uzair; Yaglidere, Oguzhan; Yeah, John; Ozcan, Aydogan

    2011-01-01

    We present a field-portable lensfree tomographic microscope, which can achieve sectional imaging of a large volume (~20 mm3) on a chip with an axial resolution of <7 μm. In this compact tomographic imaging platform (weighing only ~110 grams), 24 light-emitting diodes (LEDs) that are each butt-coupled to a fibre-optic waveguide are controlled through a cost-effective micro-processor to sequentially illuminate the sample from different angles to record lensfree holograms of the sample that is placed on the top of a digital sensor array. In order to generate pixel super-resolved (SR) lensfree holograms and hence digitally improve the achievable lateral resolution, multiple sub-pixel shifted holograms are recorded at each illumination angle by electromagnetically actuating the fibre-optic waveguides using compact coils and magnets. These SR projection holograms obtained over an angular range of ~50° are rapidly reconstructed to yield projection images of the sample, which can then be back-projected to compute tomograms of the objects on the sensor-chip. The performance of this compact and light-weight lensfree tomographic microscope is validated by imaging micro-beads of different dimensions as well as a Hymenolepis nana egg, which is an infectious parasitic flatworm. Achieving a decent three-dimensional spatial resolution, this field-portable on-chip optical tomographic microscope might provide a useful toolset for telemedicine and high-throughput imaging applications in resource-poor settings. PMID:21573311

  11. Effect of the Yield Stress and r-value Distribution on the Earing Profile of Cup Drawing with Yld2000-2d Yield Function

    NASA Astrophysics Data System (ADS)

    Lou, Yanshan; Bae, Gihyun; Lee, Changsoo; Huh, Hoon

    2010-06-01

    This paper deals with the effect of the yield stress and r-value distribution on the earing in the cup drawing. The anisotropic yield function, Yld2000-2d yield function, is selected to describe the anisotropy of two metal sheets, 719B and AA5182-O. The tool dimension is referred from the Benchmark problem of NUMISHEET'2002. The Downhill Simplex method is applied to identify the anisotropic coefficients in Yld2000-2d yield function. Simulations of the drawing process are performed to investigate the earing profile of two materials. The earing profiles obtained from simulations are compared with the analytical model developed by Hosford and Caddell. Simulations are conducted with respect to the change of the yield stress and r-value distribution, respectively. The correlation between the anisotropy and the earing tendency is investigated based on simulation data. Finally, the earing mechanism is analyzed through the deformation process of the blank during the cup deep drawing. It can be concluded that ears locate at angular positions with lower yield stress and higher r-value while the valleys appear at the angular position with higher yield stress and lower r-value. The effect of the yield stress distribution is more important for the cup height distribution than that of the r-value distribution.

  12. [The effect of OSAHS on middle ear and inner ear vestibule function advances].

    PubMed

    Li, K L; Li, J R

    2016-05-20

    Obstructive sleep apnea hypopnea syndrome(OSAHS) as a common frequentlyoccurring disease, it can cause repeated episodes of hypoxaemia and hypercapnia during sleep. With long period of hypoxaemia, obvious pathological changes and dysfunction emerged in heart,brain and lung then all kinds of clinical symptoms appear. Because of the middle ear and inner ear themselves anatomical characteristics and blood supply of regulating mechanism, they often has been damaged before the other important organ damage. As scholars have indepth study of the auditory system complications in patients with OSAHS, various influence of OSAHS on the middle ear,inner ear also gradually be known.This paper will review the effect of OSAHS on middle ear, inner ear and vestibule function, hope to have some application value for clinical work. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  13. Listening to the ear

    NASA Astrophysics Data System (ADS)

    Shera, Christopher A.

    Otoacoustic emissions demonstrate that the ear creates sound while listening to sound, offering a promising acoustic window on the mechanics of hearing in awake, listening human beings. That window is clouded, however, by an incomplete knowledge of wave reflection and transmission, both forth and back within the cochlea and through the middle ear. This thesis "does windows," addressing wave propagation and scattering on both sides of the middle ear. A summary of highlights follows. Measurements of the cochlear input impedance in cat are used to identify a new symmetry in cochlear mechanics-termed "tapering symmetry" after its geometric interpretation in simple models-that guarantees that the wavelength of the traveling wave changes slowly with position near the stapes. Waves therefore propagate without reflection through the basal turns of the cochlea. Analytic methods for solving the cochlear wave equations using a perturbative scattering series are given and used to demonstrate that, contrary to common belief, conventional cochlear models exhibit negligible internal reflection whether or not they accurately represent the tapering symmetries of the inner ear. Frameworks for the systematic "deconstruction" of eardrum and middle-ear transduction characteristics are developed and applied to the analysis of noninvasive measurements of middle-ear and cochlear mechanics. A simple phenomenological model of inner-ear compressibility that correctly predicts hearing thresholds in patients with missing or disarticulated middle-ear ossicles is developed and used to establish an upper bound on cochlear compressibility several orders of magnitude smaller than that provided by direct measurements. Accurate measurements of stimulus frequency evoked otoacoustic emissions are performed and used to determine the form and frequency variation of the cochlear traveling-wave ratio noninvasively. Those measurements are inverted to obtain the spatial distribution of mechanical

  14. Listening to the Ear

    NASA Astrophysics Data System (ADS)

    Shera, Christopher Alan

    Otoacoustic emissions demonstrate that the ear creates sound while listening to sound, offering a promising acoustic window on the mechanics of hearing in awake, listening human beings. That window is clouded, however, by an incomplete knowledge of wave reflection and transmission, both forth and back within the cochlea and through the middle ear. This thesis "does windows," addressing wave propagation and scattering on both sides of the middle ear. A summary of highlights follows. Measurements of the cochlear input impedance in cat are used to identify a new symmetry in cochlear mechanics--termed "tapering symmetry" after its geometric interpretation in simple models--that guarantees that the wavelength of the traveling wave changes slowly with position near the stapes. Waves therefore propagate without reflection through the basal turns of the cochlea. Analytic methods for solving the cochlear wave equations using a perturbative scattering series are given and used to demonstrate that, contrary to common belief, conventional cochlear models exhibit negligible internal reflection whether or not they accurately represent the tapering symmetries of the inner ear. Frameworks for the systematic "deconstruction" of eardrum and middle-ear transduction characteristics are developed and applied to the analysis of noninvasive measurements of middle-ear and cochlear mechanics. A simple phenomenological model of inner-ear compressibility that correctly predicts hearing thresholds in patients with missing or disarticulated middle-ear ossicles is developed and used to establish an upper bound on cochlear compressibility several orders of magnitude smaller than that provided by direct measurements. Accurate measurements of stimulus -frequency evoked otoacoustic emissions are performed and used to determine the form and frequency variation of the cochlear traveling-wave ratio noninvasively. Those measurements are inverted to obtain the spatial distribution of mechanical

  15. A morphometric study of the human ear.

    PubMed

    Alexander, K Skaria; Stott, David J; Sivakumar, Branavan; Kang, Norbert

    2011-01-01

    We examined variations in the shape of the human ear according to age, sex and ethnic group with particular attention to ear prominence. 420 volunteers were recruited. Measurements included; head height and length, ear height and axis, antihelix taken off angle, earlobe length and width, ear width at the helical root and tragus. Prominence was measured at the helical root and tragus (conchomastoid angle, conchal bowl depth and helical-mastoid distance). Good symmetry was shown for all measurements. Ethnically Indian volunteers had the largest ears (both length and width), followed by Caucasians, and Afro-Caribbeans. This trend was significant in males (p<0.001), but not significant in females (p=0.087). Ears increased in size throughout life. Subjectively, only 2% of volunteers felt their ears were prominent compared to 10% in the opinion of the principal investigator. No objective measurements were identified that accurately predicted subjective perceptions of prominence. We found consistent trends in ear morphology depending on ethnic group, age and sex. Our study was unable to define an objective method for assessing ear prominence. Decisions about what constitutes a prominent ear should be left to personal and aesthetic choice. Copyright © 2010 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. Listening to Nature's orchestra with peculiar ears

    NASA Astrophysics Data System (ADS)

    Yager, David D.

    2003-04-01

    Insects use hearing for the crucial tasks of communicating with conspecifics and avoiding predators. Although all are based on the same acoustic principles, the diversity of insect ears is staggering and instructive. For instance, a South African grasshopper demonstrates that hearing conspecific calls is possible over distances 1 km with ears that do not have tympana. Actually, these creatures have six pairs of ears that play different roles in behavior. In numerical contrast, praying mantises have just a single ear in the ventral midline. The ear is very effective at detecting ultrasonic bat cries. However, the bioacoustics of sound transduction by two tympana facing each other in a deep, narrow slit is a puzzle. Tachinid flies demonstrate that directional hearing at 5 kHz is possible with a pair of ears fused together to give a total size of 1 mm. The ears are under the fly's chin. Hawk moths have their ears built into their mouthparts and the tympanum is more like a hollow ball than the usual membrane. As an apt last example, cicada ears are actually part of the orchestra: their tympana function both in sound reception and sound production.

  17. Ultrasound characterization of middle ear effusion.

    PubMed

    Seth, Rahul; Discolo, Christopher M; Palczewska, Grazyna M; Lewandowski, Jan J; Krakovitz, Paul R

    2013-01-01

    To further enhance and assess the ability to characterize middle ear effusion (MEE) using non-invasive ultrasound technology. This is a prospective unblinded comparison study. Fifty-six children between the ages of 6 months and 17 years scheduled to undergo bilateral myringotomy with pressure equalization tube placement were enrolled. With the child anesthetized, the probe was placed into the external ear canal after sterile water was inserted. Ultrasound recordings of middle ear contents were analyzed by computer algorithm. Middle ear fluid was collected during myringotomy and analyzed for bacterial culture and viscosity. Ultrasound waveforms yielded a computer algorithm interpretation of middle ear contents in 66% of ears tested. When a result was obtained, the sensitivity and specificity for successfully characterizing middle ear fluid content as either void of fluid, thick fluid (mucoid), or thin fluid (serous or purulent) were at least 94%. Mucoid effusions had higher measured viscosity values (P=.002). Viscosity measures were compared to culture result, and those with low viscosity (thin consistency) had a higher likelihood of having a positive culture (P=.048). The device sensitivity and specificity for fluid detection were 94% or greater among interpretable waveforms (66% of those tested). Although this technology provides important information of the middle ear effusion presence and characteristic, further technological improvements are needed. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Ultrasound Characterization of Middle Ear Effusion

    PubMed Central

    Seth, Rahul; Discolo, Christopher M; Palczewska, Grazyna M; Lewandowski, Jan J; Krakovitz, Paul R

    2012-01-01

    Purpose To further enhance and assess the ability to characterize middle ear effusion (MEE) using non-invasive ultrasound technology. Materials and Methods This is a prospective unblinded comparison study. Fifty-six children between the ages of 6 months and 17 years scheduled to undergo bilateral myringotomy with pressure equalization tube placement were enrolled. With the child anesthetized, the probe was placed into the external ear canal after sterile water was inserted. Ultrasound recordings of middle ear contents were analyzed by computer algorithm. Middle ear fluid was collected during myringotomy and analyzed for bacterial culture and viscosity. Results Ultrasound waveforms yielded a computer algorithm interpretation of middle ear contents in 66% of ears tested. When a result was obtained, the sensitivity and specificity for successfully characterizing middle ear fluid content as either void of fluid, thick fluid (mucoid), or thin fluid (serous or purulent) was at least 94%. Mucoid effusions had higher measured viscosity values (P=0.002). Viscosity measures were compared to culture result, and those with low viscosity (thin consistency) had a higher likelihood of having a positive culture (P=0.048). Conclusion The device sensitivity and specificity for fluid detection was 94% or greater among interpretable waveforms (66% of those tested). Although this technology provides important information of the middle ear effusion presence and characteristic, further technological improvements are needed. PMID:23084430

  19. Experimental investigation of compliant wall surface deformation in a turbulent channel flow

    NASA Astrophysics Data System (ADS)

    Zhang, Cao; Wang, Jin; Katz, Joseph

    2016-11-01

    The dynamic response of a compliant wall under a turbulent channel flow is investigated by simultaneously measuring the time-resolved, 3D flow field (using tomographic PIV) and the 2D surface deformation (using interferometry). The pressure distributions are calculated by spatially integrating the material acceleration field. The Reynolds number is Reτ = 2300, and the centerline velocity (U0) is 15% of the material shear speed. The wavenumber-frequency spectra of the wall deformation contain a non-advected low-frequency component and advected modes, some traveling downstream at U0 and others at 0.72U0. Trends in the wall dynamics are elucidated by correlating the deformation with flow variables. The spatial pressure-deformation correlations peak at y/ h 0.12 (h is half channel height), the elevation of Reynolds shear stress maximum in the log-layer. Streamwise lagging of the deformation behind the pressure is caused in part by phase-lag of the pressure with decreasing distance from the wall, and in part by material damping. Positive deformations (bumps) are preferentially associated with ejections, which involve spanwise vortices located downstream and quasi-streamwise vortices with spanwise offset, consistent with hairpin-like structures. The negative deformations (dents) are preferentially associated with pressure maxima at the transition between an upstream sweep to a downstream ejection. Sponsored by ONR.

  20. An update on auricular reconstruction: three major auricular malformations of microtia, prominent ear and cryptotia.

    PubMed

    Park, Chul; Yoo, Yeon-Sik; Hong, Sung-Taek

    2010-12-01

    Microtia, prominent ear, and cryptotia are the most common types of auricular malformations. This review provides updated information on these types of reconstructions, in addition to recalling previously accepted surgical methods. Autogenous costal cartilage is still considered as an ideal material for framework fabrication in microtia reconstruction. Many surgeons have adopted the Nagata approach, the Brent approach, or variations of the two, in their work. With these employed techniques, auricles reconstructed by experienced surgeons have proven to be aesthetically promising. However, with regards to the harvesting of the costal cartilage, the underdevelopment of the chest wall donor site, alopecia of the scalp, and scarring of the postauricular-mastoid region are still considered problematic aspects of these approaches. Some articles have described attempts to solve these problems, whereas some experiments in cartilage production using tissue engineering techniques have shown promise in their initial stages of development.It is generally accepted that prominent ears should be corrected through a combination of sculpting and suture techniques, according to the individual shape and the quality of the ear prominence.Most of the cryptotia malformations show not only embedded upper auricles, but also associated adhesions of the upper auricular cartilage. Their correction should therefore resolve both deformities. A number of articles highlighting clinical experiences with auricular reconstructions for microtia, prominent ear, and cryptotia have been included in this review. We believe that the information synthesized here will become a basis for further development of auricular reconstruction techniques.

  1. Vestibular sensory functional status of cochlear implanted ears versus non-implanted ears in bilateral profound deaf adults.

    PubMed

    Cozma, Romică Sebastian; Dima-Cozma, Lucia Corina; Rădulescu, Luminiţa Mihaela; Hera, Maria Cristina; Mârţu, Cristian; Olariu, Raluca; Cobzeanu, Bogdan Mihail; Bitere, Oana Roxana; Cobzeanu, Mihail Dan

    2018-01-01

    Patients with hearing loss who underwent cochlear implantation can present symptomatic or asymptomatic vestibular damages earlier or later after the surgery. The vestibular permanent lesions could be acute, produced by surgical trauma or could be progressive due to local morphological changes made by the presence of the portelectrode in the inner ear (fibrosis related, ossification, basilar membrane distortion, endolymphatic hydrops). Besides histopathological findings in inner ear of cochlear implanted patients, the vestibular permanent damages could be found by assessment of clinical vestibular status. This study reports the sensorial vestibular functional findings for adults in cochlear implanted ears related to the electrode insertion type (cochleostomy or round window approach) and comparing to non-implanted deaf ears. A total of 20 adult patients with 32 cochlear implanted ears (12 patients with binaural cochlear implant and eight with monoaural) were selected for postoperatory vestibular examination by cervical and ocular vestibular myogenic potentials and vestibular caloric tests. The same tests were made for a control group of 22 non-implanted deaf ears. Functional testing results were reported related to the electrode insertion approach. For the cochleostomy group, we found different deficits: in 40% for saccular function, 44% for utricular function, and 12% horizontal canal dysfunction. In round window group, the deficit was present in 14.29% for saccular function, 28.57% for utricular function, and 28.58% for horizontal canal. In 46.88% of implanted ears, the vestibular function was completely preserved on all tested sensors. In conclusion, the vestibular functional status after inner ear surgery presents sensorial damages in 53.12% ears compare with the vestibular dysfunction existing in 50% of deaf non-operated ears. Round window insertion allows for better conservation of the vestibular function.

  2. Acoustic representation of tomographic data

    NASA Astrophysics Data System (ADS)

    Wampler, Cheryl; Zahrt, John D.; Hotchkiss, Robert S.; Zahrt, Rebecca; Kust, Mark

    1993-04-01

    Tomographic data and tomographic reconstructions are naturally periodic in the angle of rotation of the turntable and the polar angel of the coordinates in the object, respectively. Similarly, acoustic waves are periodic and have amplitude and wavelength as free parameters that can be fit to another representation. Work has been in progress for some time in bringing the acoustic senses to bear on large data sets rather than just the visual sense. We will provide several different acoustic representations of both raw data and density maps. Rather than graphical portrayal of the data and reconstructions, you will be presented various 'tone poems.'

  3. Is Attention Shared Between the Ears?1

    PubMed Central

    Shiffrin, Richard M.; Pisoni, David B.; Castaneda-Mendez, Kicab

    2012-01-01

    This study tests the locus of attention during selective listening for speech-like stimuli. Can processing be differentially allocated to the two ears? Two conditions were used. The simultaneous condition involved one of four randomly chosen stop-consonants being presented to one of the ears chosen at random. The sequential condition involved two intervals; in the first S listened to the right ear; in the second S listened to the left ear. One of the four consonants was presented to an attended ear during one of these intervals. Experiment I used no distracting stimuli. Experiment II utilized a distracting consonant not confusable with any of the four target consonants. This distractor was always presented to any ear not containing a target. In both experiments, simultaneous and sequential performance were essentially identical, despite the need for attention sharing between the two ears during the simultaneous condition. We conclude that selective attention does not occur during perceptual processing of speech sounds presented to the two ears. We suggest that attentive effects arise in short-term memory following processing. PMID:23226838

  4. 21 CFR 870.2710 - Ear oximeter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ear oximeter. 870.2710 Section 870.2710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2710 Ear oximeter. (a) Identification. An ear...

  5. Can Loud Music Hurt My Ears?

    MedlinePlus

    ... Videos for Educators Search English Español Can Loud Music Hurt My Ears? KidsHealth / For Kids / Can Loud Music Hurt My Ears? Print en español La música ... up? Oh! You want to know if loud music can hurt your ears . Are you asking because ...

  6. 21 CFR 870.2710 - Ear oximeter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear oximeter. 870.2710 Section 870.2710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2710 Ear oximeter. (a) Identification. An ear...

  7. Immunologic Disorders of the Inner Ear.

    ERIC Educational Resources Information Center

    Kinney, William C.; Hughes, Gordon B.

    1997-01-01

    Immune inner ear disease represents a series of immune system mediated problems that can present with hearing loss, dizziness, or both. The etiology, presentation, testing, and treatment of primary immune inner ear disease is discussed. A review of secondary immune inner ear disease is presented for comparison. (Contains references.) (Author/CR)

  8. Rugby injury-associated pseudocyst of the auricle: report and review of sports-associated dermatoses of the ear.

    PubMed

    Kallini, Joseph R; Cohen, Philip R

    2013-02-15

    To describe a man with pseudocyst of the auricle, summarize the salient features of this condition, and review other sports-associated dermatoses of the ear. Pseudocyst of the auricle is an intracartilaginous collection of viscous straw-colored fluid typically located in the triangular fossa of the upper half of the auricle. It is usually asymptomatic. It can result in a permanent auricular deformity. A 63-year-old man developed a pseudocyst of the auricle following a traumatic rugby-related injury to his left ear. The lesion has persisted for many years; chronic massage has slightly decreased its size. The etiology of pseudocyst of the auricle has been described as either traumatic or developmental. Our patient developed his pseudocyst after a rugby-related injury. This condition is usually unilateral. Aspirate of the content is usually sterile. Histology shows an intracartilaginous cyst devoid of an epithelial lining. Treatment involves either partial removal of the cartilage or chemical irritation to enhance adhesiveness. Subsequent compression (via button bolsters) minimizes recurrence. Pseudocyst of the auricle is a benign cystic dilatation, which is intracartilaginous, devoid of an epithelial lining, and may be traumatic or non-traumatic in origin. A man with rugby-associated trauma to his left ear developed this condition. Auricular pseudocyst can be added to the list of sports-associated dermatoses of the ear.

  9. 3D Printed Bionic Ears

    PubMed Central

    Mannoor, Manu S.; Jiang, Ziwen; James, Teena; Kong, Yong Lin; Malatesta, Karen A.; Soboyejo, Winston O.; Verma, Naveen; Gracias, David H.; McAlpine, Michael C.

    2013-01-01

    The ability to three-dimensionally interweave biological tissue with functional electronics could enable the creation of bionic organs possessing enhanced functionalities over their human counterparts. Conventional electronic devices are inherently two-dimensional, preventing seamless multidimensional integration with synthetic biology, as the processes and materials are very different. Here, we present a novel strategy for overcoming these difficulties via additive manufacturing of biological cells with structural and nanoparticle derived electronic elements. As a proof of concept, we generated a bionic ear via 3D printing of a cell-seeded hydrogel matrix in the precise anatomic geometry of a human ear, along with an intertwined conducting polymer consisting of infused silver nanoparticles. This allowed for in vitro culturing of cartilage tissue around an inductive coil antenna in the ear, which subsequently enables readout of inductively-coupled signals from cochlea-shaped electrodes. The printed ear exhibits enhanced auditory sensing for radio frequency reception, and complementary left and right ears can listen to stereo audio music. Overall, our approach suggests a means to intricately merge biologic and nanoelectronic functionalities via 3D printing. PMID:23635097

  10. 3D printed bionic ears.

    PubMed

    Mannoor, Manu S; Jiang, Ziwen; James, Teena; Kong, Yong Lin; Malatesta, Karen A; Soboyejo, Winston O; Verma, Naveen; Gracias, David H; McAlpine, Michael C

    2013-06-12

    The ability to three-dimensionally interweave biological tissue with functional electronics could enable the creation of bionic organs possessing enhanced functionalities over their human counterparts. Conventional electronic devices are inherently two-dimensional, preventing seamless multidimensional integration with synthetic biology, as the processes and materials are very different. Here, we present a novel strategy for overcoming these difficulties via additive manufacturing of biological cells with structural and nanoparticle derived electronic elements. As a proof of concept, we generated a bionic ear via 3D printing of a cell-seeded hydrogel matrix in the anatomic geometry of a human ear, along with an intertwined conducting polymer consisting of infused silver nanoparticles. This allowed for in vitro culturing of cartilage tissue around an inductive coil antenna in the ear, which subsequently enables readout of inductively-coupled signals from cochlea-shaped electrodes. The printed ear exhibits enhanced auditory sensing for radio frequency reception, and complementary left and right ears can listen to stereo audio music. Overall, our approach suggests a means to intricately merge biologic and nanoelectronic functionalities via 3D printing.

  11. Strain partitioning in shales during elastic and creep deformation observed by synchrotron X-ray micro-tomography.

    NASA Astrophysics Data System (ADS)

    Sone, H.; Cheung, C.; Rivers, M. L.; Wang, Y.; Yu, T.

    2016-12-01

    Knowledge about the ductile time-dependent constitutive behavior of geological materials is essential when evaluating the long-term integrity of subsurface structures and predicting the long-term geomechanical response of the surrounding formations. To this end, it is not only important to measure the bulk time-dependent behavior but also essential to understand the microscale mechanism by which rocks exhibit time-dependence, because laboratory data needs to be extrapolated to time-scales much beyond laboratory experiments. We conducted long-term creep experiments using Green River shale samples and obtained synchrotron X-ray images during the tests in an attempt to capture the microscale strain-partitioning that occurs within the sample. Shale samples of few millimeter dimensions were stressed up to several tens of MPa by a spring-loaded device within an X-ray transparent load frame, and the load was held constant for up to several months to allow creep deformation. Tomographic images of about 5 micron resolution were reconstructed from images collected at different timings of the experiment, which allows us to investigate where and how much strain localized during elastic and creep deformation. Tracking the position of some outstanding features in the rock texture (e.g. pyrite grains, organic material patches) indicate that strain magnitudes expected from the sample elastic and relaxation modulus can be successfully recovered from the tomographic images. We also attempt to use digital volume correlation to track sub-voxel displacements and to characterize the spatial heterogeneity of the deformation.

  12. What Is an Ear Infection?

    MedlinePlus

    ... Hearing Loss? Taking Care of Your Ears Swimmer's Ear Perforated Eardrum What's Earwax? View ... All information on KidsHealth® is for educational purposes only. For specific medical advice, diagnoses, and treatment, ...

  13. [Atypical inflammation of the middle ear].

    PubMed

    Garov, E V; Kryukov, A I; Zelenkova, V N; Sidorina, N G; Kaloshina, A S

    The objective of the present study was to characterize the patients presenting with atypical inflammation of the middle ear and consider the currently available methods for their examination. A total of 20 patients at the age from 16 to 66 years were admitted to the Department of Ear Microsurgery during the period from 2008 and 2016 for the treatment of atypical inflammation of the middle ear. Eleven of them (18 ears) were found to have tuberculous lesions (TL) of the middle ear while the remaining 9 patients (11 ears) suffered giant cell vasculitis (GCV). All the patients underwent the general clinical and otorhinolaryngological examination, computed tomography of the temporal bones and the thoracic cavity organs, cytological, bacteriological, pathomorphological, and molecular-genetic studies including PCR diagnostics, rheumatological tests, as well as counseling by a phthisiotherapist and rheumatologist. The primary localization of TL in the middle ear was documented in 6 patients including its association with lung lesions in 5 cases. The clinical picture of the disease in 5 patients was that of smoldering exudative pathology and in 6 ones was accompanied by suppurative perforative otitis media. According to the laboratory analyses, bacteriological diagnostics proved efficient in 9% of the patients, pathomorphological and cytological diagnostics in 18% and 27.3% of the cases respectively while the effectiveness of PCR diagnostics was estimated at 55%. The diagnosis in individual patients was established within the period from 1 month to 1.5 years after they first sought medical advice in connection with complaints of the ear disease. Tuberculosis of the middle ear began to develop as exudative middle otitis that acquired the form of bilateral pathology in 4 patients. Three patients had a concomitant pulmonary disease. In 4 patuents, the diagnois of middle ear tuberculosis was established based on the presence of the specific antibodies and in 5 ones based on the

  14. Finite-Element Modelling of the Acoustic Input Admittance of the Newborn Ear Canal and Middle Ear.

    PubMed

    Motallebzadeh, Hamid; Maftoon, Nima; Pitaro, Jacob; Funnell, W Robert J; Daniel, Sam J

    2017-02-01

    Admittance measurement is a promising tool for evaluating the status of the middle ear in newborns. However, the newborn ear is anatomically very different from the adult one, and the acoustic input admittance is different than in adults. To aid in understanding the differences, a finite-element model of the newborn ear canal and middle ear was developed and its behaviour was studied for frequencies up to 2000 Hz. Material properties were taken from previous measurements and estimates. The simulation results were within the range of clinical admittance measurements made in newborns. Sensitivity analyses of the material properties show that in the canal model, the maximum admittance and the frequency at which that maximum admittance occurs are affected mainly by the stiffness parameter; in the middle-ear model, the damping is as important as the stiffness in influencing the maximum admittance magnitude but its effect on the corresponding frequency is negligible. Scaling up the geometries increases the admittance magnitude and shifts the resonances to lower frequencies. The results suggest that admittance measurements can provide more information about the condition of the middle ear when made at multiple frequencies around its resonance.

  15. Ear - blocked at high altitudes

    MedlinePlus

    ... ears; Flying and blocked ears; Eustachian tube dysfunction - high altitude ... to the eardrum) and the back of the nose and upper throat. ... down from high altitudes. Chewing gum the entire time you are ...

  16. Transmission matrix analysis of the chinchilla middle ear

    PubMed Central

    Songer, Jocelyn E.; Rosowski, John J.

    2008-01-01

    Despite the common use of the chinchilla as an animal model in auditory research, a complete characterization of the chinchilla middle ear using transmission matrix analysis has not been performed. In this paper we describe measurements of middle-ear input admittance and stapes velocity in ears with the middle-ear cavity opened under three conditions: intact tympano-ossicular system and cochlea, after the cochlea has been drained, and after the stapes has been fixed. These measurements, made with stimulus frequencies of 100–8000 Hz, are used to define the transmission matrix parameters of the middle ear and to calculate the cochlear input impedance as well as the middle-ear output impedance. This transmission characterization of the chinchilla middle ear will be useful for modeling auditory sensitivity in the normal and pathological chinchilla ear. PMID:17672642

  17. Treating "cauliflower ear" with silicone mold.

    PubMed

    Gross, C G

    1978-01-01

    Acute hematoma of the ear (cauliflower ear) can be satisfactorily treated with aspiration and the use of the silicone mold to prevent reaccumulation of the blood or serum in the ear. Advantages of the silicone mold over other dressings appears to be ease of application, patient acceptance, and prevention of reoccurrence of reaccumulation of the hematoma.

  18. Communication routes between intracranial spaces and inner ear: function, pathophysiologic importance and relations with inner ear diseases.

    PubMed

    Ciuman, Raphael R

    2009-01-01

    There exist 3 communication routes between the intracranial space and the inner ear, the vestibular aqueduct, the cochlear aqueduct, and the internal auditory canal. They possess a key role in inner ear pressure regulation and fluid homeostasis and are related to inner ear diseases. Relevant literature was reviewed, and the current knowledge of the anatomy, physiologic importance, and relations to inner ear diseases were described. Pathologic communication routes such as semicircular canal dehiscence syndrome were highlighted as well. Abnormalities in all 3 communication routes may predispose or be the cause of distinct inner ear pathologic condition and involved in other cochlear and vestibular syndromes, in which their role is not completely clear. The increasing knowledge of the underlying mechanisms encourages promising approaches for possible intervention in the future.

  19. Molecular Mechanisms of Inner Ear Development

    PubMed Central

    Wu, Doris K.; Kelley, Matthew W.

    2012-01-01

    The inner ear is a structurally complex vertebrate organ built to encode sound, motion, and orientation in space. Given its complexity, it is not surprising that inner ear dysfunction is a relatively common consequence of human genetic mutation. Studies in model organisms suggest that many genes currently known to be associated with human hearing impairment are active during embryogenesis. Hence, the study of inner ear development provides a rich context for understanding the functions of genes implicated in hearing loss. This chapter focuses on molecular mechanisms of inner ear development derived from studies of model organisms. PMID:22855724

  20. Molecular mechanisms of inner ear development.

    PubMed

    Wu, Doris K; Kelley, Matthew W

    2012-08-01

    The inner ear is a structurally complex vertebrate organ built to encode sound, motion, and orientation in space. Given its complexity, it is not surprising that inner ear dysfunction is a relatively common consequence of human genetic mutation. Studies in model organisms suggest that many genes currently known to be associated with human hearing impairment are active during embryogenesis. Hence, the study of inner ear development provides a rich context for understanding the functions of genes implicated in hearing loss. This chapter focuses on molecular mechanisms of inner ear development derived from studies of model organisms.

  1. Middle ear impedance measurements in large vestibular aqueduct syndrome.

    PubMed

    Bilgen, Cem; Kirkim, Günay; Kirazli, Tayfun

    2009-06-01

    To assess the effect of inner ear pressure on middle ear impedance in patients with large vestibular aqueduct syndrome (LVAS). Data from admittance tympanometry and multifrequency tympanometry on 8 LVAS patients and control subjects were studied. Static acoustic compliance (SAC) values for the ears with stable sensorineural hearing loss (SNHL) were within the limits of the mean values of control groups except for two ears. The resonance frequency (RF) values of the ears with stable SNHL were lower than the mean values of control groups except for three ears. SAC values for the two ears with fluctuating SNHL were lower and the RF values were higher than the mean values of control groups. Decreased SAC values and increased RF values found in the ears with fluctuating SNHL might be an indirect indicator of increased inner ear pressure, while low RF values in the ears with stable SNHL might reflect the decreased inner ear impedance.

  2. Deriving the real-ear SPL of audiometric data using the "coupler to dial difference" and the "real ear to coupler difference".

    PubMed

    Munro, K J; Davis, J

    2003-04-01

    The purpose of the study was to compare the measured real-ear sound pressure level (SPL) of audiometer output with the derived real-ear SPL obtained by adding the coupler to dial difference (CDD) and real-ear to coupler difference (RECD) to the audiometer dial reading. The real-ear SPL and RECD were measured in one ear of 16 normally hearing subjects using a probe-tube microphone. The CDD transform and the RECD transfer function were measured in an HA1 and an HA2 2-cc coupler using an EAR-LINK foam ear-tip or a customized earmold. The RECD transfer function was measured using the EARTone ER 3A and the Audioscan RE770 insert earphone. The procedures were very reliable with mean differences on retest of less than 1 dB. The mean difference between the measured and derived real-ear SPL was generally less than 1 dB and rarely exceeded 3 dB in any subject. The CDD measured for an individual audiometer and the RECD measured for an individual ear can be used to derive a valid estimate of real-ear SPL when it has not been possible to measure this directly.

  3. Comparison of Microbiological Flora in the External Auditory Canal of Normal Ear and an Ear with Acute Otitis Externa.

    PubMed

    Ghanpur, Asheesh Dora; Nayak, Dipak Ranjan; Chawla, Kiran; Shashidhar, V; Singh, Rohit

    2017-09-01

    Acute Otitis Externa (AOE) is also known as swimmer's ear. Investigations initiated during World War II firmly established the role of bacteria in the aetiology of Acute Otitis Externa. To culture the microbiological flora of the normal ear and compare it with the flora causing AOE and to know the role of normal ear canal flora and anaerobes in the aetiology. A prospective observational study was conducted on 64 patients clinically diagnosed with unilateral AOE. Ear swabs were taken from both the ears. Microbiological flora was studied considering diseased ear as test ear and the normal ear as the control. Aerobic and anaerobic cultures were done. Severity of the disease was assessed by subjective and objective scores. Effect of topical treatment with ichthammol glycerine pack was assessed after 48 hours and scores were calculated again. Patients with scores < 4 after pack removal were started on systemic antibiotics and were assessed after seven days of antibiotics course. Data was analysed using Paired t-test, Wilcoxon signed ranks test and Chi-square test. A p-value < 0.05 was considered significant. Pseudomonas aeruginosa (33%) was the most common bacteria cultured from the ear followed by Methicillin Resistant Staphylococcus aureus (MRSA) (18%). Patients with anaerobic organism in the test ear had severe symptoms and needed systemic antibiotic therapy. Most of the cases may respond to empirical antibiotic therapy. In cases with severe symptoms and the ones refractory to empirical treatment, a culture from the ear canal will not be a tax on the patient. This helps in giving a better understanding about the disease, causative organisms and helps in avoiding the use of inappropriate antibiotics that usually result in developing resistant strains of bacteria.

  4. Middle-ear velocity transfer function, cochlear input immittance, and middle-ear efficiency in chinchilla.

    PubMed

    Ravicz, Michael E; Rosowski, John J

    2013-10-01

    The transfer function H(V) between stapes velocity V(S) and sound pressure near the tympanic membrane P(TM) is a descriptor of sound transmission through the middle ear (ME). The ME power transmission efficiency (MEE), the ratio of sound power entering the cochlea to power entering the middle ear, was computed from H(V) measured in seven chinchilla ears and previously reported measurements of ME input admittance Y(TM) and ME pressure gain G(MEP) [Ravicz and Rosowski, J. Acoust. Soc. Am. 132, 2437-2454 (2012); J. Acoust. Soc. Am. 133, 2208-2223 (2013)] in the same ears. The ME was open, and a pressure sensor was inserted into the cochlear vestibule for most measurements. The cochlear input admittance Y(C) computed from H(V) and G(MEP) is controlled by a combination of mass and resistance and is consistent with a minimum-phase system up to 27 kHz. The real part Re{Y(C)}, which relates cochlear sound power to inner-ear sound pressure, decreased gradually with frequency up to 25 kHz and more rapidly above that. MEE was about 0.5 between 0.1 and 8 kHz, higher than previous estimates in this species, and decreased sharply at higher frequencies.

  5. Middle-ear velocity transfer function, cochlear input immittance, and middle-ear efficiency in chinchilla

    PubMed Central

    Ravicz, Michael E.; Rosowski, John J.

    2013-01-01

    The transfer function HV between stapes velocity VS and sound pressure near the tympanic membrane PTM is a descriptor of sound transmission through the middle ear (ME). The ME power transmission efficiency (MEE), the ratio of sound power entering the cochlea to power entering the middle ear, was computed from HV measured in seven chinchilla ears and previously reported measurements of ME input admittance YTM and ME pressure gain GMEP [Ravicz and Rosowski, J. Acoust. Soc. Am. 132, 2437–2454 (2012); J. Acoust. Soc. Am. 133, 2208–2223 (2013)] in the same ears. The ME was open, and a pressure sensor was inserted into the cochlear vestibule for most measurements. The cochlear input admittance YC computed from HV and GMEP is controlled by a combination of mass and resistance and is consistent with a minimum-phase system up to 27 kHz. The real part Re{YC}, which relates cochlear sound power to inner-ear sound pressure, decreased gradually with frequency up to 25 kHz and more rapidly above that. MEE was about 0.5 between 0.1 and 8 kHz, higher than previous estimates in this species, and decreased sharply at higher frequencies. PMID:24116422

  6. CT of the ear in Pendred syndrome.

    PubMed

    Goldfeld, Moshe; Glaser, Benjamin; Nassir, Elias; Gomori, John Moshe; Hazani, Elitsur; Bishara, Nassir

    2005-05-01

    To prospectively determine the structural anomalies of the inner ear by using thin-section computed tomography (CT) in an extended family with Pendred syndrome. Ethics committee approved the study, and informed consent was obtained from every patient or from parents of patients under legal age. Twelve patients (three females and nine males aged 7-47 years) with Pendred syndrome (all from the same ethnic isolate and with the same mutation in the PDS gene) were evaluated for inner-ear malformation at thin-section CT. Both ears were evaluated. Presence or absence of interscalar septum between upper and middle turns of the cochlea was evaluated, and vestibule and vestibular aqueduct were examined for enlargement. Modiolus was determined to be present or absent (modiolar deficiency). CT scans were evaluated in consensus by two radiologists (M.G., J.M.G.). All patients had inner ear malformation on both sides. Modiolus was absent and vestibule was enlarged on both sides in all 12 patients. Interscalar septum was absent in 18 (75%) of 24 ears. In eight patients, interscalar septum was absent in both ears, whereas in two patients, it was absent on only one side. Aqueduct was enlarged in 20 (80%) of 24 ears. In nine patients, both ears had enlarged aqueducts, while in two patients, only one side was abnormal. Inner ear malformation is an invariable finding in Pendred syndrome. Modiolus deficiency and vestibular enlargement were the most consistent anomalies in this population with Pendred syndrome. (c) RSNA, 2005.

  7. The ideal ear position in Caucasian females.

    PubMed

    Broer, P Niclas; Thiha, Aung; Ehrl, Denis; Sinno, Sammy; Juran, Sabrina; Szpalski, Caroline; Ng, Reuben; Ninkovic, Milomir; Prantl, Lukas; Heidekrueger, Paul I

    2018-03-01

    Ear position contributes significantly to facial appearance. However, while objective measurements remain the foundation for esthetic evaluations, little is known about how an ear should ideally be positioned regarding its rotational axis. This study aimed to further evaluate whether there exists a universally applicable ideal ear axis, and how sociodemographic factors impact such preferences. An interactive online survey was designed, enabling participants to change the axis of a female model's ear in terms of its forward and backward rotation. The questionnaire was sent out internationally to plastic surgeons and the general public. Demographic data were collected and analysis of variance was used to investigate respective preferences. A total of 1016 responses from 35 different countries (response rate: 18.5%) were gathered. Overall, 60% of survey takers chose the minus 10 or 5° angles to be most attractive. Significant differences were found regarding sex, ethnicity, country of residence, profession and respective ear axis preferences. Across multiple countries and ethnicities, an ear position in slight reclination of minus 5-10° is considered most pleasing in Caucasian females. However, sociodemographic factors significantly impact individual ear axis preferences and should be taken into consideration when performing reconstructive ear surgery. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Stem Cell Therapy for the Inner Ear

    PubMed Central

    Okano, Takayuki

    2012-01-01

    In vertebrates, perception of sound, motion, and balance is mediated through mechanosensory hair cells located within the inner ear. In mammals, hair cells are only generated during a short period of embryonic development. As a result, loss of hair cells as a consequence of injury, disease, or genetic mutation, leads to permanent sensory deficits. At present, cochlear implantation is the only option for profound hearing loss. However, outcomes are still variable and even the best implant cannot provide the acuity of a biological ear. The recent emergence of stem cell technology has the potential to open new approaches for hair cell regeneration. The goal of this review is to summarize the current state of inner ear stem cell research from a viewpoint of its clinical application for inner ear disorders to illustrate how complementary studies have the potential to promote and refine stem cell therapies for inner ear diseases. The review initially discusses our current understanding of the genetic pathways that regulate hair cell formation from inner ear progenitors during normal development. Subsequent sections discuss the possible use of endogenous inner ear stem cells to induce repair as well as the initial studies aimed at transplanting stem cells into the ear. PMID:22514095

  9. Optical tomographic memories: algorithms for the efficient information readout

    NASA Astrophysics Data System (ADS)

    Pantelic, Dejan V.

    1990-07-01

    Tomographic alogithms are modified in order to reconstruct the inf ormation previously stored by focusing laser radiation in a volume of photosensitive media. Apriori information about the position of bits of inf ormation is used. 1. THE PRINCIPLES OF TOMOGRAPHIC MEMORIES Tomographic principles can be used to store and reconstruct the inf ormation artificially stored in a bulk of a photosensitive media 1 The information is stored by changing some characteristics of a memory material (e. g. refractive index). Radiation from the two independent light sources (e. g. lasers) is f ocused inside the memory material. In this way the intensity of the light is above the threshold only in the localized point where the light rays intersect. By scanning the material the information can be stored in binary or nary format. When the information is stored it can be read by tomographic methods. However the situation is quite different from the classical tomographic problem. Here a lot of apriori information is present regarding the p0- sitions of the bits of information profile representing single bit and a mode of operation (binary or n-ary). 2. ALGORITHMS FOR THE READOUT OF THE TOMOGRAPHIC MEMORIES Apriori information enables efficient reconstruction of the memory contents. In this paper a few methods for the information readout together with the simulation results will be presented. Special attention will be given to the noise considerations. Two different

  10. Numerical analysis of ossicular chain lesion of human ear

    NASA Astrophysics Data System (ADS)

    Liu, Yingxi; Li, Sheng; Sun, Xiuzhen

    2009-04-01

    Lesion of ossicular chain is a common ear disease impairing the sense of hearing. A comprehensive numerical model of human ear can provide better understanding of sound transmission. In this study, we propose a three-dimensional finite element model of human ear that incorporates the canal, tympanic membrane, ossicular bones, middle ear suspensory ligaments/muscles, middle ear cavity and inner ear fluid. Numerical analysis is conducted and employed to predict the effects of middle ear cavity, malleus handle defect, hypoplasia of the long process of incus, and stapedial crus defect on sound transmission. The present finite element model is shown to be reasonable in predicting the ossicular mechanics of human ear.

  11. Expression of macrophage migration inhibitory factor and CD74 in the inner ear and middle ear in lipopolysaccharide-induced otitis media.

    PubMed

    Ishihara, Hisashi; Kariya, Shin; Okano, Mitsuhiro; Zhao, Pengfei; Maeda, Yukihide; Nishizaki, Kazunori

    2016-10-01

    Significant expression of macrophage migration inhibitory factor and its receptor (CD74) was observed in both the middle ear and inner ear in experimental otitis media in mice. Modulation of macrophage migration inhibitory factor and its signaling pathway might be useful in the management of inner ear inflammation due to otitis media. Inner ear dysfunction secondary to otitis media has been reported. However, the specific mechanisms involved are not clearly understood. The aim of this study is to investigate the expression of macrophage migration inhibitory factor and CD74 in the middle ear and inner ear in lipopolysaccharide-induced otitis media. BALB/c mice received a transtympanic injection of either lipopolysaccharide or phosphate-buffered saline (PBS). The mice were sacrificed 24 h after injection, and temporal bones were processed for polymerase chain reaction (PCR) analysis, histologic examination, and immunohistochemistry. PCR examination revealed that the lipopolysaccharide-injected mice showed a significant up-regulation of macrophage migration inhibitory factor in both the middle ear and inner ear as compared with the PBS-injected control mice. The immunohistochemical study showed positive reactions for macrophage migration inhibitory factor and CD74 in infiltrating inflammatory cells, middle ear mucosa, and inner ear in the lipopolysaccharide-injected mice.

  12. The comparative anatomy of the pig middle ear cavity: a model for middle ear inflammation in the human?

    PubMed Central

    PRACY, J. P.; WHITE, A.; MUSTAFA, Y.; SMITH, D.; PERRY, M. E.

    1998-01-01

    This study was undertaken to develop a functional model of otitis media with effusion (OME) in the pig (Sus scrofa), with the purpose of investigating the origin of lymphocytes populating the middle ear during the course of an inflammatory process. The relevance of the model to the human condition of OME is to a large extent dependent on the anatomical and physiological similarities between the middle ear cavity and the pharyngeal lymphoid tissue of the pig and man. Anatomical specimens were collected from 7 young Large White pigs to determine the gross anatomy of the middle ear cavity and the histological characteristics of the middle ear mucosa. It was found that the anatomy of the 3 parts of the middle ear cavity in man and in the pig is broadly similar, although some minor differences were observed. The porcine eustachian tube was seen to be cartilaginous throughout its length in contrast to the part osseous, part cartilaginous structure found in man; the porcine ossicles were slightly different in shape to those of man and the air cell system was situated inferior to the tympanic cavity in the pig as opposed to posteriorly in man. This paper describes the structure and morphology of the pig middle ear cavity and compares and contrasts it with that of man. The minor differences observed are of anatomical importance but do not diminish the usefulness of the pig middle ear cleft as a potential model for human middle ear disorders. PMID:9688502

  13. Facial Asymmetry: Brow and Ear Position.

    PubMed

    Perumal, Balaji; Meyer, Dale R

    2018-04-01

    The purpose of the current study was to analyze brow and ear position, and examine the relationship between these structures in patients presenting for blepharoplasty evaluation. A retrospective chart review was performed, which included all patients presenting to one oculoplastic physician for a blepharoplasty evaluation from November, 2012 to March, 2014. The prevalence of brow ptosis and brow and ear asymmetry was calculated; the proportional distribution was determined, and chi-square analysis and the z-test of proportions were used to calculate the significance. Institutional Review Board approval was obtained for this study. A total of 133 patients met the inclusion criteria. Some degree of brow ptosis was noted in 83% of patients. Brow asymmetry was found in 88% of patients, and ear asymmetry in 77%. Of those patients who had asymmetry, 61% had the right brow lower and 75% had the right ear lower; 73% of all patients had the brow and ear lower on the same side ( p  < 0.001). In this study, brow ptosis and asymmetry were quite common. In addition, the side of the lower brow correlated strongly with the side of the lower ear, and the right side structures were lower more often than the left. Patients presenting for blepharoplasty evaluation may have an element of generalized facial asymmetry which includes the brows and ears. These observations can be important for preoperative planning and patient counseling. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Biometric recognition using 3D ear shape.

    PubMed

    Yan, Ping; Bowyer, Kevin W

    2007-08-01

    Previous works have shown that the ear is a promising candidate for biometric identification. However, in prior work, the preprocessing of ear images has had manual steps and algorithms have not necessarily handled problems caused by hair and earrings. We present a complete system for ear biometrics, including automated segmentation of the ear in a profile view image and 3D shape matching for recognition. We evaluated this system with the largest experimental study to date in ear biometrics, achieving a rank-one recognition rate of 97.8 percent for an identification scenario and an equal error rate of 1.2 percent for a verification scenario on a database of 415 subjects and 1,386 total probes.

  15. Acceleration induced water removal from ear canals.

    NASA Astrophysics Data System (ADS)

    Kang, Hosung; Averett, Katelee; Jung, Sunghwan

    2017-11-01

    Children and adults commonly experience having water trapped in the ear canals after swimming. To remove the water, individuals will shake their head sideways. Since a child's ear canal has a smaller diameter, it requires more acceleration of the head to remove the trapped water. In this study, we theoretically and experimentally investigated the acceleration required to break the surface meniscus of the water in artificial ear canals and hydrophobic-coated glass tubes. In experiments, ear canal models were 3D-printed from a CT-scanned human head. Also, glass tubes were coated with silane to match the hydrophobicity in ear canals. Then, using a linear stage, we measured the acceleration values required to forcefully eject the water from the artificial ear canals and glass tubes. A theoretical model was developed to predict the critical acceleration at a given tube diameter and water volume by using a modified Rayleigh-Taylor instability. Furthermore, this research can shed light on the potential of long-term brain injury and damage by shaking the head to push the water out of the ear canal. This research was supported by National Science Foundation Grant CBET-1604424.

  16. Passage of albumin from the middle ear to the inner ear in otitis media in the chinchilla

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldberg, B.; Goycoolea, M.V.; Schleivert, P.M.

    1981-08-01

    A study of the permeability of the middle ear-inner ear interface for macromolecules was carried out in chinchillas with open and obstructed eustachian tubes utilizing tritiated human serum albumin and immunoelectrophoresis. Tritiated albumin was placed in the round window niche area or normal animals and animals in which the eustachian tubes had been obstructed for 24 hours or 14 days. The tritiated albumin was allowed to remain in the middle ear cavity for 24 hours, Samples of middle ear effusion, perilymph, blood and cerebrospinal fluid were collected and measured for radioactivity. Radioactivity was demonstrated in the perilymph. Samples of middlemore » ear effusions and perilymph were also studied by immunoelectrophoresis with goat antihuman albumin. Albumin placed in the round window niche of an experimental animal could be recovered unchanged in the perilymph. The results suggest a pathophysiologic explanation for the association of otitis media and sensorineural hearing loss or endolymphatic hydrops.« less

  17. Fly-ear inspired acoustic sensors for gunshot localization

    NASA Astrophysics Data System (ADS)

    Liu, Haijun; Currano, Luke; Gee, Danny; Yang, Benjamin; Yu, Miao

    2009-05-01

    The supersensitive ears of the parasitoid fly Ormia ochracea have inspired researchers to develop bio-inspired directional microphone for sound localization. Although the fly ear is optimized for localizing the narrow-band calling song of crickets at 5 kHz, experiments and simulation have shown that it can amplify directional cues for a wide frequency range. In this article, a theoretical investigation is presented to study the use of fly-ear inspired directional microphones for gunshot localization. Using an equivalent 2-DOF model of the fly ear, the time responses of the fly ear structure to a typical shock wave are obtained and the associated time delay is estimated by using cross-correlation. Both near-field and far-field scenarios are considered. The simulation shows that the fly ear can greatly amplify the time delay by ~20 times, which indicates that with an interaural distance of only 1.2 mm the fly ear is able to generate a time delay comparable to that obtained by a conventional microphone pair with a separation as large as 24 mm. Since the parameters of the fly ear structure can also be tuned for muzzle blast and other impulse stimulus, fly-ear inspired acoustic sensors offers great potential for developing portable gunshot localization systems.

  18. Incorporating anthropometry into design of ear-related products.

    PubMed

    Liu, Bor-Shong

    2008-01-01

    To achieve mass customization and collaborative product design, human factors and ergonomics should play a key development role. The purpose of this study was to provide product designers with the anthropometic dimensions of outer ears for different demographic data, including gender and age. The second purpose was to compare the dimensions of various ear-related products (i.e., earphone, bluetooth earphone and ear-cup earphone) with the anthropometic database and recommend appropriate solutions for design. Two hundred subjects aged 20-59 was selected for this study and divided into four age stratifications. Further, three different dimensions of the outer ear (i.e., the earhole length, the ear connection length and the length of the pinna) were measured by superimposed grid photographic technique. The analysis of variance (ANOVA) was used to investigate the effects of gender, and age on ear dimensions. The results showed that all ear dimensions had significant gender effects. A comparison between the anthropometric dimensions and those of current products revealed that most current ear-related products need to be redesigned using anthropometric data. The shapes of earhole and pinna are not circular. Consequently, ear products need to be elongated so that users may feel more comfortably and not have the product slip off easily.

  19. Pinna abnormalities and low-set ears

    MedlinePlus

    ... Pinna abnormalities; Genetic defect - pinna; Congenital defect - pinna Images Ear abnormalities Pinna of the newborn ear References Haddad J, Keesecker S. Congenital malformations. In: Kliegman RM, Stanton BF, ...

  20. System and method for generating motion corrected tomographic images

    DOEpatents

    Gleason, Shaun S [Knoxville, TN; Goddard, Jr., James S.

    2012-05-01

    A method and related system for generating motion corrected tomographic images includes the steps of illuminating a region of interest (ROI) to be imaged being part of an unrestrained live subject and having at least three spaced apart optical markers thereon. Simultaneous images are acquired from a first and a second camera of the markers from different angles. Motion data comprising 3D position and orientation of the markers relative to an initial reference position is then calculated. Motion corrected tomographic data obtained from the ROI using the motion data is then obtained, where motion corrected tomographic images obtained therefrom.

  1. Correlations of Surface Deformation and 3D Flow Field in a Compliant Wall Turbulent Channel Flow.

    NASA Astrophysics Data System (ADS)

    Wang, Jin; Zhang, Cao; Katz, Joseph

    2015-11-01

    This study focuses on the correlations between surface deformation and flow features, including velocity, vorticity and pressure, in a turbulent channel flow over a flat, compliant Polydimethylsiloxane (PDMS) wall. The channel centerline velocity is 2.5 m/s, and the friction Reynolds number is 2.3x103. Analysis is based on simultaneous measurements of the time resolved 3D velocity and surface deformation using tomographic PIV and Mach-Zehnder Interferometry. The volumetric pressure distribution is calculated plane by plane by spatially integrating the material acceleration using virtual boundary, omni-directional method. Conditional sampling based on local high/low pressure and deformation events reveals the primary flow structures causing the deformation. High pressure peaks appear at the interface between sweep and ejection, whereas the negative deformations peaks (dent) appear upstream, under the sweeps. The persistent phase lag between flow and deformations are presumably caused by internal damping within the PDMS. Some of the low pressure peaks and strong ejections are located under the head of hairpin vortices, and accordingly, are associated with positive deformation (bump). Others bumps and dents are correlated with some spanwise offset large inclined quasi-streamwise vortices that are not necessarily associated with hairpins. Sponsored by ONR.

  2. Single-stage autologous ear reconstruction for microtia.

    PubMed

    Kasrai, Leila; Snyder-Warwick, Alison K; Fisher, David M

    2014-03-01

    The authors have been using the Nagata technique since 2002. In this review of 100 consecutive ear reconstructions, the authors present technique modifications that have evolved over this period that have contributed to improved auricular contour and that now allow for auricular reconstruction in a single stage. This study is a retrospective review of a prospectively acquired database. The series is restricted to primary reconstructions performed for congenital microtia. Photographs of 10 consecutive patients are presented to demonstrate the results of the technique. Surgical complication rates are discussed. One hundred ear reconstructions were performed in 96 patients. There were 75 primary cases of congenital microtia. Twenty-four ears underwent a two-stage reconstruction, and 51 ears were reconstructed with a Nagata stage I procedure or a single-stage reconstruction. There was a gradual shift in technique, with a trend to perform fewer Nagata stage II outsetting procedures and more single-stage reconstructions. In patients who underwent an ear reconstruction in two stages, the surgical complication rate was 22 percent. In the last 40 consecutive ear reconstructions since abandoning the two-stage approach, the surgical complication rate is now 15 percent. A modification of Nagata's technique of autologous ear reconstruction for microtia is described. Modifications of the three-dimensional framework address the contour of the inferior crus and control tragal projection and position. Inclusion of a projection block and recruitment of retroauricular skin allow for symmetric projection of the ear in a single stage. Therapeutic, IV.

  3. Audiometric Predictions Using SFOAE and Middle-Ear Measurements

    PubMed Central

    Ellison, John C.; Keefe, Douglas H.

    2006-01-01

    Objective The goals of the study are to determine how well stimulus-frequency otoacoustic emissions (SFOAEs) identify hearing loss, classify hearing loss as mild or moderate-severe, and correlate with pure-tone thresholds in a population of adults with normal middle-ear function. Other goals are to determine if middle-ear function as assessed by wideband acoustic transfer function (ATF) measurements in the ear canal account for the variability in normal thresholds, and if the inclusion of ATFs improves the ability of SFOAEs to identify hearing loss and predict pure-tone thresholds. Design The total suppressed SFOAE signal and its corresponding noise were recorded in 85 ears (22 normal ears and 63 ears with sensorineural hearing loss) at octave frequencies from 0.5 – 8 kHz using a nonlinear residual method. SFOAEs were recorded a second time in three impaired ears to assess repeatability. Ambient-pressure ATFs were obtained in all but one of these 85 ears, and were also obtained from an additional 31 normal-hearing subjects in whom SFOAE data were not obtained. Pure-tone air-and bone-conduction thresholds and 226-Hz tympanograms were obtained on all subjects. Normal tympanometry and the absence of air-bone gaps were used to screen subjects for normal middle-ear function. Clinical decision theory was used to assess the performance of SFOAE and ATF predictors in classifying ears as normal or impaired, and linear regression analysis was used to test the ability of SFOAE and ATF variables to predict the air-conduction audiogram. Results The ability of SFOAEs to classify ears as normal or hearing impaired was significant at all test frequencies. The ability of SFOAEs to classify impaired ears as either mild or moderate-severe was significant at test frequencies from 0.5 to 4 kHz. SFOAEs were present in cases of severe hearing loss. SFOAEs were also significantly correlated with air-conduction thresholds from 0.5 to 8 kHz. The best performance occurred using the SFOAE

  4. An Effective 3D Ear Acquisition System

    PubMed Central

    Liu, Yahui; Lu, Guangming; Zhang, David

    2015-01-01

    The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. It can be easily captured from a distance without a fully cooperative subject. Also, the ear has a relatively stable structure that does not change much with the age and facial expressions. In this paper, we present a novel method of 3D ear acquisition system by using triangulation imaging principle, and the experiment results show that this design is efficient and can be used for ear recognition. PMID:26061553

  5. An Effective 3D Ear Acquisition System.

    PubMed

    Liu, Yahui; Lu, Guangming; Zhang, David

    2015-01-01

    The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. It can be easily captured from a distance without a fully cooperative subject. Also, the ear has a relatively stable structure that does not change much with the age and facial expressions. In this paper, we present a novel method of 3D ear acquisition system by using triangulation imaging principle, and the experiment results show that this design is efficient and can be used for ear recognition.

  6. Animal models of middle ear cholesteatoma.

    PubMed

    Yamamoto-Fukuda, Tomomi; Takahashi, Haruo; Koji, Takehiko

    2011-01-01

    Middle ear acquired cholesteatoma is a pathological condition associated with otitis media, which may be associated with temporal bone resorption, otorrhea and hearing loss, and occasionally various other complications. Cholesteatoma is characterized by the enhanced proliferation of epithelial cells with aberrant morphologic characteristics. Unfortunately, our understanding of the mechanism underlying its pathogenesis is limited. To investigate its pathogenesis, different animal models have been used. This paper provides a brief overview of the current status of research in the field of pathogenesis of middle ear acquired cholesteatoma, four types of animal models previously reported on, up-to-date cholesteatoma research using these animal models, our current studies of the local hybrid ear model, and the future prospect of new animal models of middle ear cholesteatoma.

  7. Animal Models of Middle Ear Cholesteatoma

    PubMed Central

    Yamamoto-Fukuda, Tomomi; Takahashi, Haruo; Koji, Takehiko

    2011-01-01

    Middle ear acquired cholesteatoma is a pathological condition associated with otitis media, which may be associated with temporal bone resorption, otorrhea and hearing loss, and occasionally various other complications. Cholesteatoma is characterized by the enhanced proliferation of epithelial cells with aberrant morphologic characteristics. Unfortunately, our understanding of the mechanism underlying its pathogenesis is limited. To investigate its pathogenesis, different animal models have been used. This paper provides a brief overview of the current status of research in the field of pathogenesis of middle ear acquired cholesteatoma, four types of animal models previously reported on, up-to-date cholesteatoma research using these animal models, our current studies of the local hybrid ear model, and the future prospect of new animal models of middle ear cholesteatoma. PMID:21541229

  8. Ear Infection in Isolated Cleft Lip: Etiological Implications

    PubMed Central

    Ruegg, Teresa A.; Cooper, Margaret E.; Leslie, Elizabeth J.; Ford, Matthew D.; Wehby, George L.; Deleyiannis, Frederic W.B.; Czeizel, Andrew E.; Hecht, Jacqueline T.; Marazita, Mary L.; Weinberg, Seth M.

    2015-01-01

    Background and Hypothesis Chronic ear infections are a common occurrence in children with orofacial clefts involving the secondary palate. Less is known about the middle ear status of individuals with isolated clefts of the lip, although several studies have reported elevated rates of ear infection in this group. The purpose of this retrospective study was to test the hypothesis that chronic ear infections occur more frequently in isolated cleft lip cases (n=94) compared with controls (n=183). Methods A questionnaire was used to obtain information on history of chronic ear infection. The association between ear infection status (present/absent) and cleft lip status (cleft lip case/control) was tested using both chi-square and logistic regression. Results and Conclusions The reported occurrence of chronic ear infection was significantly greater in cleft lipcases (31%) compared to unaffected controls (11%). After adjusting for age and sex, having a cleft lip increased the odds of being positive for ear infection by a factor greater than three (OR=3.698; 95%CI=1.91–7.14). Within cleft lipcases, there was no difference in the occurrence of ear infection by defect laterality or by the type of clefting present in the family history. Although velopharyngeal insufficiency was present in 18.4% of our cleft lip sample, there was no statistical association between ear infection and abnormal speech patterns. These results may have potential implications both for the clinical management of isolated cleft lip cases and for understanding the etiology of orofacial clefting. PMID:26153759

  9. Ear Infection in Isolated Cleft Lip: Etiological Implications.

    PubMed

    Ruegg, Teresa A; Cooper, Margaret E; Leslie, Elizabeth J; Ford, Matthew D; Wehby, George L; Deleyiannis, Frederic W B; Czeizel, Andrew E; Hecht, Jacqueline T; Marazita, Mary L; Weinberg, Seth M

    2017-03-01

      Chronic ear infections are a common occurrence in children with orofacial clefts involving the secondary palate. Less is known about the middle ear status of individuals with isolated clefts of the lip, although several studies have reported elevated rates of ear infection in this group. The purpose of this retrospective study was to test the hypothesis that chronic ear infections occur more frequently in isolated cleft lip cases (n = 94) compared with controls (n = 183).   A questionnaire was used to obtain information on history of chronic ear infection. The association between ear infection status (present/absent) and cleft lip status (cleft lip case/control) was tested using both chi-square and logistic regression.   The reported occurrence of chronic ear infection was significantly greater in cleft lip cases (31%) compared with unaffected controls (11%). After adjusting for age and sex, having a cleft lip increased the odds of being positive for ear infection by a factor greater than 3 (odds ratio = 3.698; 95% confidence interval = 1.91 to 7.14). Within cleft lip cases, there was no difference in the occurrence of ear infection by defect laterality or by the type of clefting present in the family history. Although velopharyngeal insufficiency was present in 18.4% of our cleft lip sample, there was no statistical association between ear infection and abnormal speech patterns. These results may have potential implications both for the clinical management of isolated cleft lip cases and for understanding the etiology of orofacial clefting.

  10. X-ray tomographic imaging of tensile deformation modes of electrospun biodegradable polyester fibres

    NASA Astrophysics Data System (ADS)

    Maksimcuka, Jekaterina; Obata, Akiko; Sampson, William W.; Blanc, Remi; Gao, Chunxia; Withers, Philip J.; Tsigkou, Olga; Kasuga, Toshihiro; Lee, Peter D.; Poologasundarampillai, Gowsihan

    2017-12-01

    Electrospinning allows the production of fibrous networks for tissue engineering, drug delivery and wound healing in healthcare. It enables the production of constructs with large surface area and a fibrous morphology that closely resembles the extracellular matrix of many tissues. A fibrous structure not only promotes cell attachment and tissue formation, but could also lead to very interesting mechanical properties. Poly(3-hydroxybutyrate-co-4-hydroxybutyrate) (P(3HB-co-4HB)) is a biodegradable polyester that exhibits large (>400%) elongation before failure. In this study, synchrotron X-ray phase contrast imaging was performed during tensile deformation to failure on a non-woven fibre mat of P(3HB-co-4HB) fibres. Significant reorientation of the fibres in straining direction was observed, followed by localised necking and eventual failure. From an original average fibre diameter of 4.3 μm a bimodal distribution of fibre diameter (modal diameters of 1.9 and 3.7 μm) formed after tensile deformation. Extensive localised necking (thinning) of fibres between (thicker) fibre-fibre contacts was found to be the cause for non-uniform thinning of the fibres, a phenomenon that is expected, but has not been observed in 3D previously. The data presented here has implications not only in tissue regeneration but for fibrous materials in general.

  11. Ear tag

    MedlinePlus

    ... an ear tag or pit are: An inherited tendency to have this facial feature A genetic syndrome ... Elsevier Churchill Livingstone; 2016:chap 19. Review Date 4/24/2017 Updated by: Liora C Adler, MD, ...

  12. Ear Infections

    MedlinePlus

    ... but they are less common. The infection usually affects the middle ear and is called otitis media. ... become clogged with fluid and mucus. This can affect hearing, because sound cannot get through all that ...

  13. Ear emergencies

    MedlinePlus

    ... and ruptured eardrums can be caused by: Inserting cotton swabs, toothpicks, pins, pens, or other objects into ... The person will have severe pain. Place sterile cotton gently in the outer ear canal to keep ...

  14. Effects of Varieties, Producing Areas, Ears, and Ear Positions of Single Maize Kernels on Near-Infrared Spectra for Identification and Traceability.

    PubMed

    An, Dong; Cui, Yongjin; Liu, Xu; Jia, Shiqiang; Zheng, Shuyun; Che, Xiaoping; Liu, Zhe; Zhang, Xiaodong; Zhu, Dehai; Li, Shaoming

    2016-01-01

    The effects of varieties, producing areas, ears, and ear positions of maize on near-infrared (NIR) spectra were investigated to determine the factors causing the differences in NIR fingerprints of maize varieties. A total of 130 inbred lines were grown in two regions in China, and 12,350 kernel samples were analyzed through NIR spectroscopy. Spectral differences among varieties, producing areas, ears, and ear positions were determined and compared on the basis of pretreated spectra. The bands at 1300-1470, 1768-1949, 2010-2064, and 2235-2311 nm were mainly affected by the producing area. Band selection and principal component analysis were applied to improve the influence of variety on NIR spectra by processing the pretreated spectra. The degrees of the influence of varieties, producing areas, ears, and ear positions were calculated, and the percentages of the influence of varieties, producing areas, ears, and ear positions were 45.40%, 42.66%, 8.22%, and 3.72%, respectively. Therefore, genetic differences among maize inbred lines are the main factors accounted for NIR spectral differences. Producing area is a secondary factor. These results could provide a reference for researchers who authenticate varieties, perform geographical origin traceabilities, and conduct maize seed breeding.

  15. Pierced Ears

    MedlinePlus

    ... weeks. Then you can start enjoying your pierced ears again! Reviewed by: Steven Dowshen, MD Date reviewed: September ... All information on KidsHealth® is for educational purposes only. For specific medical advice, diagnoses, and treatment, ...

  16. Fumonisin B(1)-nonproducing strains of Fusarium verticillioides cause maize (Zea mays) ear infection and ear rot.

    PubMed

    Desjardins, A E; Plattner, R D

    2000-11-01

    Fumonisins are polyketide mycotoxins produced by Fusarium verticillioides (synonym F. moniliforme), a major pathogen of maize (Zea mays) worldwide. Most field strains produce high levels of fumonisin B(1) (FB(1)) and low levels of the less-oxygenated homologues FB(2) and FB(3), but fumonisin B(1)-nonproducing field strains have been obtained by natural variation. To test the role of various fumonisins in pathogenesis on maize under field conditions, one strain producing FB(1), FB(2), and FB(3), one strain producing only FB(2), one strain producing only FB(3), and one fumonisin-nonproducing strain were applied to ears via the silk channel and on seeds at planting. Disease severity on the harvested ears was evaluated by visible symptoms and by weight percent symptomatic kernels. Fumonisin levels in kernels were determined by high-performance liquid chromatography. The presence of the applied FB(1)-nonproducing strains in kernels was determined by analysis of recovered strains for fumonisin production and other traits. All three FB(1)-nonproducing strains were able to infect ears following either silk-channel application or seed application at planting and were as effective as the FB(1)-producing strain in causing ear rot following silk-channel application. These results indicate that production of FB(1), FB(2), or FB(3) is not required for F. verticillioides to cause maize ear infection and ear rot.

  17. Computational Modeling of Blast Wave Transmission Through Human Ear.

    PubMed

    Leckness, Kegan; Nakmali, Don; Gan, Rong Z

    2018-03-01

    Hearing loss has become the most common disability among veterans. Understanding how blast waves propagate through the human ear is a necessary step in the development of effective hearing protection devices (HPDs). This article presents the first 3D finite element (FE) model of the human ear to simulate blast wave transmission through the ear. The 3D FE model of the human ear consisting of the ear canal, tympanic membrane, ossicular chain, and middle ear cavity was imported into ANSYS Workbench for coupled fluid-structure interaction analysis in the time domain. Blast pressure waveforms recorded external to the ear in human cadaver temporal bone tests were applied at the entrance of the ear canal in the model. The pressure waveforms near the tympanic membrane (TM) in the canal (P1) and behind the TM in the middle ear cavity (P2) were calculated. The model-predicted results were then compared with measured P1 and P2 waveforms recorded in human cadaver ears during blast tests. Results show that the model-derived P1 waveforms were in an agreement with the experimentally recorded waveforms with statistic Kurtosis analysis. The FE model will be used for the evaluation of HPDs in future studies.

  18. Anthropometric growth study of the ear in a Chinese population.

    PubMed

    Zhao, Shichun; Li, Dianguo; Liu, Zhenzhong; Wang, Yibiao; Liu, Lei; Jiang, Duyin; Pan, Bo

    2018-04-01

    A large number of anthropometric studies of the auricle have been reported in different nations, but little data were available in the Chinese population. The aim of this study was to analyze growth changes in the ear by measuring the width and length of ears in a Chinese population. A total of 480 participants were enrolled and classified into 1-, 3-, 5-, 7-, 9-, 12-, 14-, and 18-year groups (half were boys and half were girls in each group). Ear length, ear width, body weight, and body length were measured and recorded; ear index was calculated according to ear length and ear width. The growth of auricle and differences between genders were analyzed. Growth of ear in relation to body height and weight and the degree of emphasis on the length and width of the auricle were also analyzed. Ear length and width increased with age. Ear length achieved its mature size in both 14-year-old males and females. Ear width reached its mature size in males at 7 years and in females at 5 years. Different trends of ear index were shown between males and females. People in this population paid more attention to the length than the width of the auricle. The data indicated that ear development followed increase in age. There were gender and ethnic difference in the development of ear. These results may have potential implications for the diagnosis of congenital malformations, syndromes, and planning of ear reconstruction surgery. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. Insights into inner ear-specific gene regulation: epigenetics and non-coding RNAs in inner ear development and regeneration

    PubMed Central

    Avraham, Karen B.

    2016-01-01

    The vertebrate inner ear houses highly specialized sensory organs, tuned to detect and encode sound, head motion and gravity. Gene expression programs under the control of transcription factors orchestrate the formation and specialization of the non-sensory inner ear labyrinth and its sensory constituents. More recently, epigenetic factors and non-coding RNAs emerged as an additional layer of gene regulation, both in inner ear development and disease. In this review, we provide an overview on how epigenetic modifications and non-coding RNAs, in particular microRNAs (miRNAs), influence gene expression and summarize recent discoveries that highlight their critical role in the proper formation of the inner ear labyrinth and its sensory organs. In contrast to non-mammalian vertebrates, adult mammals lack the ability to regenerate inner ear mechano-sensory hair cells. Finally, we discuss recent insights into how epigenetic factors and miRNAs may facilitate, or in the case of mammals, restrict sensory hair cell regeneration. PMID:27836639

  20. Musical ear syndrome in adult cochlear implant patients.

    PubMed

    Low, W-K; Tham, C A; D'Souza, V-D; Teng, S-W

    2013-09-01

    Except for a single case report, musical ear syndrome in cochlear implantees has not been studied. We aimed to study the prevalence and nature of musical ear syndrome among adult cochlear implant patients, as well as the effect on their emotional well-being. STUDY DESIGN, PATIENTS AND INTERVENTION: A cross-sectional survey of patients aged 18 years and above who had received cochlear implants for profound hearing loss between 1997 and 2010. Of the 82 patients studied, 18 (22 per cent) were found to have experienced musical ear syndrome. Seven and 11 patients had musical ear syndrome prior to and after cochlear implantation, respectively. The character of musical ear syndrome symptoms was described as instrumental music (n = 2), singing (6) or both (10). Fourteen patients reported an adverse emotional effect, with three expressing ‘intolerance’. In this study, 22 per cent of cochlear implantees experienced musical ear syndrome. These symptoms affected patients’ emotional state, but most coped well. Musical ear syndrome can occur prior to and after cochlear implantation.

  1. [Adaptability of sweet corn ears to a frozen process].

    PubMed

    Ramírez Matheus, Alejandra O; Martínez, Norelkys Maribel; de Bertorelli, Ligia O; De Venanzi, Frank

    2004-12-01

    The effects of frozen condition on the quality of three sweet corn ears (2038, 2010, 2004) and the pattern (Bonanza), were evaluated. Biometrics characteristics like ear size, ear diameter, row and kernel deep were measured as well as chemical and physical measurement in fresh and frozen states. The corn ears were frozen at -95 degrees C by 7 minutes. The yield and stability of the frozen ears were evaluated at 45 and 90 days of frozen storage (-18 degrees C). The average commercial yield as frozen corn ear for all the hybrids was 54.2%. The industry has a similar value range of 48% to 54%. The ear size average was 21.57 cm, row number was 15, ear diameter 45.54 mm and the kernel corn deep was 8.57 mm. All these measurements were found not different from commercial values found for the industry. All corn samples evaluated showed good stability despites the frozen processing and storage. Hybrid 2038 ranked higher in quality.

  2. Distortion product otoacoustic emissions upon ear canal pressurization.

    PubMed

    Zebian, Makram; Schirkonyer, Volker; Hensel, Johannes; Vollbort, Sven; Fedtke, Thomas; Janssen, Thomas

    2013-04-01

    The purpose of this study was to quantify the change in distortion product otoacoustic emission (DPOAE) level upon ear canal pressurization. DPOAEs were measured on 12 normal-hearing human subjects for ear canal static pressures between -200 and +200 daPa in (50 ± 5) daPa steps. A clear dependence of DPOAE levels on the pressure was observed, with levels being highest at the maximum compliance of the middle ear, and decreasing on average by 2.3 dB per 50 daPa for lower and higher pressures. Ear canal pressurization can serve as a tool for improving the detectability of DPOAEs in the case of middle-ear dysfunction.

  3. Cilia and Ear.

    PubMed

    Piatti, Gioia; De Santi, Maria Margherita; Torretta, Sara; Pignataro, Lorenzo; Soi, Daniela; Ambrosetti, Umberto

    2017-04-01

    To investigate the prevalence of otological complications derived from primary ciliary dyskinesia (PCD) in adulthood. Twenty-three patients with diagnosed PCD underwent medical history aimed at recording the presence of ear, nose, and throat manifestations (ENT) and any surgical treatments. The ENT objectivity was annotated, and then patients were subjected to audiometric test, tympanometry, registration of otoacoustic emission, and vestibular evaluation. Otitis media with chronic middle ear effusion (OME) during childhood was reported in 52% of the subjects, no patient had undergone ear surgery, and only 2 patients had an episode of otitis in the last year. Eleven of 23 patients showed normal hearing, 11 had a conductive hearing impairment, and 1 showed a severe sensorineural hearing loss unrelated to the syndrome. The bilateral stapedial reflex was only found in all cases of normoacusia and type A tympanogram, distortion product otoacoustic emissions (DPOAE) were present in 8 patients, and no patient had vestibular alterations. Our study confirms a very frequent prevalence of OME in PCD during childhood. Careful monitoring of otological complications of the syndrome is always desirable, also given the high presence in adults of other manifestations in the upper airways, such as chronic rhinosinusitis and nasal polyposis.

  4. Sheep as a large animal ear model: Middle-ear ossicular velocities and intracochlear sound pressure.

    PubMed

    Péus, Dominik; Dobrev, Ivo; Prochazka, Lukas; Thoele, Konrad; Dalbert, Adrian; Boss, Andreas; Newcomb, Nicolas; Probst, Rudolf; Röösli, Christof; Sim, Jae Hoon; Huber, Alexander; Pfiffner, Flurin

    2017-08-01

    Animals are frequently used for the development and testing of new hearing devices. Dimensions of the middle ear and cochlea differ significantly between humans and commonly used animals, such as rodents or cats. The sheep cochlea is anatomically more like the human cochlea in size and number of turns. This study investigated the middle-ear ossicular velocities and intracochlear sound pressure (ICSP) in sheep temporal bones, with the aim of characterizing the sheep as an experimental model for implantable hearing devices. Measurements were made on fresh sheep temporal bones. Velocity responses of the middle ear ossicles at the umbo, long process of the incus and stapes footplate were measured in the frequency range of 0.25-8 kHz using a laser Doppler vibrometer system. Results were normalized by the corresponding sound pressure level in the external ear canal (P EC ). Sequentially, ICSPs at the scala vestibuli and tympani were then recorded with custom MEMS-based hydrophones, while presenting identical acoustic stimuli. The sheep middle ear transmitted most effectively around 4.8 kHz, with a maximum stapes velocity of 0.2 mm/s/Pa. At the same frequency, the ICSP measurements in the scala vestibuli and tympani showed the maximum gain relative to the P EC (24 dB and 5 dB, respectively). The greatest pressure difference across the cochlear partition occurred between 4 and 6 kHz. A comparison between the results of this study and human reference data showed middle-ear resonance and best cochlear sensitivity at higher frequencies in sheep. In summary, sheep can be an appropriate large animal model for research and development of implantable hearing devices. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Predicting skin deficits through surface area measurements in ear reconstruction and adult ear surface area norms.

    PubMed

    Yazar, Memet; Sevim, Kamuran Zeynep; Irmak, Fatih; Yazar, Sevgi Kurt; Yeşilada, Ayşin Karasoy; Karşidağğ, Semra Hacikerim; Tatlidede, Hamit Soner

    2013-07-01

    Ear reconstruction is one of the most challenging procedures in plastic surgery practice. Many studies and techniques have been described in the literature for carving a well-pronounced framework. However, just as important as the cartilage framework is the ample amount of delicate skin coverage of the framework. In this report, we introduce an innovative method of measuring the skin surface area of the auricle from a three-dimensional template created from the healthy ear.The study group consisted of 60 adult Turkish individuals who were randomly selected (30 men and 30 women). The participant ages ranged from 18 to 45 years (mean, 31.5 years), and they had no history of trauma or congenital anomalies. The template is created by dividing the ear into aesthetic subunits and using ImageJ software to estimate the necessary amount of total skin surface area required.Reconstruction of the auricle is a complicated process that requires experience and patience to provide the auricular details. We believe this estimate will shorten the learning curve for residents and surgeons interested in ear reconstruction and will help surgeons obtain adequate skin to drape over the well-sculpted cartilage frameworks by providing a reference list of total ear skin surface area measurements for Turkish men and women.

  6. Middle ear infection (otitis media) (image)

    MedlinePlus

    Otitis media is an inflammation or infection of the middle ear. Acute otitis media (acute ear infection) occurs when there is ... which causes production of fluid or pus. Chronic otitis media occurs when the eustachian tube becomes blocked ...

  7. Alternative splicing of inner-ear-expressed genes.

    PubMed

    Wang, Yanfei; Liu, Yueyue; Nie, Hongyun; Ma, Xin; Xu, Zhigang

    2016-09-01

    Alternative splicing plays a fundamental role in the development and physiological function of the inner ear. Inner-ear-specific gene splicing is necessary to establish the identity and maintain the function of the inner ear. For example, exon 68 of Cadherin 23 (Cdh23) gene is subject to inner-ear-specific alternative splicing, and as a result, Cdh23(+ 68) is only expressed in inner ear hair cells. Alternative splicing along the tonotopic axis of the cochlea contributes to frequency tuning, particularly in lower vertebrates, such as chickens and turtles. Differential splicing of Kcnma1, which encodes for the α subunit of the Ca(2+)-activated K(+) channel (BK channel), has been suggested to affect the channel gating properties and is important for frequency tuning. Consequently, deficits in alternative splicing have been shown to cause hearing loss, as we can observe in Bronx Waltzer (bv) mice and Sfswap mutant mice. Despite the advances in this field, the regulation of alternative splicing in the inner ear remains elusive. Further investigation is also needed to clarify the mechanism of hearing loss caused by alternative splicing deficits.

  8. Image processing pipeline for synchrotron-radiation-based tomographic microscopy.

    PubMed

    Hintermüller, C; Marone, F; Isenegger, A; Stampanoni, M

    2010-07-01

    With synchrotron-radiation-based tomographic microscopy, three-dimensional structures down to the micrometer level can be visualized. Tomographic data sets typically consist of 1000 to 1500 projections of 1024 x 1024 to 2048 x 2048 pixels and are acquired in 5-15 min. A processing pipeline has been developed to handle this large amount of data efficiently and to reconstruct the tomographic volume within a few minutes after the end of a scan. Just a few seconds after the raw data have been acquired, a selection of reconstructed slices is accessible through a web interface for preview and to fine tune the reconstruction parameters. The same interface allows initiation and control of the reconstruction process on the computer cluster. By integrating all programs and tools, required for tomographic reconstruction into the pipeline, the necessary user interaction is reduced to a minimum. The modularity of the pipeline allows functionality for new scan protocols to be added, such as an extended field of view, or new physical signals such as phase-contrast or dark-field imaging etc.

  9. Forgotten T-tube in the middle ear.

    PubMed

    Shakeel, Muhammad; Trinidade, Aaron; Khan, Imran; Ah-See, Kim Wong

    2012-05-01

    Retention within the middle ear cleft is an unusual complication of T-tube insertion. A 40-year-old woman with Kartagener's Syndrome presented with hearing impairment in the right ear. She was found to have a previously inserted Goode T-tube lying within the middle ear behind an intact drum. She underwent successful removal of the T-tube via a myringotomy, and a new tube was re-inserted. Migration of a T-tube into the middle ear cleft should always be kept in mind in patients who present with otological symptoms and have a history of T-tube insertion, even in the presence of an intact drum.

  10. Swimmer's ear

    MedlinePlus

    ... often gets better with the proper treatment. Possible Complications The infection may spread to other areas around the ear, including the skull bone. In older people or those who have diabetes, the infection may become severe. This condition is ...

  11. EARS: Electronic Access to Reference Service.

    PubMed

    Weise, F O; Borgendale, M

    1986-10-01

    Electronic Access to Reference Service (EARS) is a front end to the Health Sciences Library's electronic mail system, with links to the online public catalog. EARS, which became operational in September 1984, is accessed by users at remote sites with either a terminal or microcomputer. It is menu-driven, allowing users to request: a computerized literature search, reference information, a photocopy of a journal article, or a book. This paper traces the history of EARS and discusses its use, its impact on library staff and services, and factors that influence the diffusion of new technology.

  12. Physiological artifacts in scalp EEG and ear-EEG.

    PubMed

    Kappel, Simon L; Looney, David; Mandic, Danilo P; Kidmose, Preben

    2017-08-11

    A problem inherent to recording EEG is the interference arising from noise and artifacts. While in a laboratory environment, artifacts and interference can, to a large extent, be avoided or controlled, in real-life scenarios this is a challenge. Ear-EEG is a concept where EEG is acquired from electrodes in the ear. We present a characterization of physiological artifacts generated in a controlled environment for nine subjects. The influence of the artifacts was quantified in terms of the signal-to-noise ratio (SNR) deterioration of the auditory steady-state response. Alpha band modulation was also studied in an open/closed eyes paradigm. Artifacts related to jaw muscle contractions were present all over the scalp and in the ear, with the highest SNR deteriorations in the gamma band. The SNR deterioration for jaw artifacts were in general higher in the ear compared to the scalp. Whereas eye-blinking did not influence the SNR in the ear, it was significant for all groups of scalps electrodes in the delta and theta bands. Eye movements resulted in statistical significant SNR deterioration in both frontal, temporal and ear electrodes. Recordings of alpha band modulation showed increased power and coherence of the EEG for ear and scalp electrodes in the closed-eyes periods. Ear-EEG is a method developed for unobtrusive and discreet recording over long periods of time and in real-life environments. This study investigated the influence of the most important types of physiological artifacts, and demonstrated that spontaneous activity, in terms of alpha band oscillations, could be recorded from the ear-EEG platform. In its present form ear-EEG was more prone to jaw related artifacts and less prone to eye-blinking artifacts compared to state-of-the-art scalp based systems.

  13. Use of the 'real-ear to dial difference' to derive real-ear SPL from hearing level obtained with insert earphones.

    PubMed

    Munro, K J; Lazenby, A

    2001-10-01

    The electroacoustic characteristics of a hearing instrument are normally selected for individuals using data obtained during audiological assessment. The precise inter-relationship between the electroacoustic and audiometric variables is most readily appreciated when they have been measured at the same reference point, such as the tympanic membrane. However, it is not always possible to obtain the real-ear sound pressure level (SPL) directly if this is below the noise floor of the probe-tube microphone system or if the subject is unco-operative. The real-ear SPL may be derived by adding the subject's real-ear to dial difference (REDD) acoustic transform to the audiometer dial setting. The aim of the present study was to confirm the validity of the Audioscan RM500 to measure the REDD with the ER-3A insert earphone. A probe-tube microphone was used to measure the real-ear SPL and REDD from the right ears of 16 adult subjects ranging in age from 22 to 41 years (mean age 27 years). Measurements were made from 0.25 kHz to 6 kHz at a dial setting of 70 dB with an ER-3A insert earphone and two earmould configurations: the EAR-LINK foam ear-tip and the subjects' customized skeleton earmoulds. Mean REDD varied as a function of frequency but was typically approximately 12 dB with a standard deviation (SD) of +/- 1.7 dB and +/- 2.7 dB for the foam ear-tip and customized earmould, respectively. The mean test-retest difference of the REDD varied with frequency but was typically 0.5 dB (SD 1 dB). Over the frequency range 0.5-4 kHz, the derived values were found to be within 5 dB of the measured values in 95% of subjects when using the EAR-LINK foam ear-tip and within 4 dB when using the skeleton earmould. The individually measured REDD transform can be used in clinical practice to derive a valid estimate of real-ear SPL when it has not been possible to measure this directly.

  14. Structures that Contribute to Middle-Ear Admittance in Chinchilla

    PubMed Central

    Rosowski, John J.; Ravicz, Michael E.; Songer, Jocelyn E.

    2009-01-01

    We describe measurements of middle-ear input admittance in chinchillas (Chinchilla lanigera) before and after various manipulations that define the contributions of different middle-ear components to function. The chinchilla’s middle-ear air spaces have a large effect on the low-frequency compliance of the middle ear, and removing the influences of these spaces reveals a highly admittant tympanic membrane and ossicular chain. Measurements of the admittance of the air spaces reveal that the high-degree of segmentation of these spaces has only a small effect on the admittance. Draining the cochlea further increases the middle-ear admittance at low frequencies and removes a low-frequency (less than 300 Hz) level dependence in the admittance. Spontaneous or sound-driven contractions of the middle-ear muscles in deeply anesthetized animals were associated with significant changes in middle-ear admittance. PMID:16944166

  15. Cauliflower Ear and Skin Infections among Wrestlers in Tehran.

    PubMed

    Kordi, Ramin; Mansournia, Mohammad Ali; Nourian, Roh Allah; Wallace, W Angus

    2007-01-01

    The purpose of the study was to describe the magnitude of the selected sports medicine problems (i.e. cauliflower ear and skin infections) among wrestlers in Tehran. A number of 411 wrestlers were randomly selected from wrestling clubs in Tehran employing cluster sample setting method. The participants were interviewed using a specially designed and validated questionnaire. Nearly half of the participants (44%) had "cauliflower ears". Only 23% of these participants had received any kind of treatment for their acute ear haematomas that are known to result in "cauliflower ears". The prevalence of reported hearing loss among participants with cauliflower ears (11.5%, 95%CI: 6.9 to 16.2) was significantly more than this prevalence among those participants without cauliflower ears (1.8%, 95%CI: 0.1 to 3.5) (p < 0.05). More than half of the participants (52%) had skin infection diagnosed by a physician during the previous year. This study has identified evidence of an increase in hearing loss as a possible side effect of either cauliflower ear or ear injury in wrestling in Iran. There has been an outbreak of ringworm and there is a significant potential for an outbreak of impetigo among wrestlers in Tehran. Key pointsSkin infections are prevalent among wrestlers in Tehran.Commonly wrestlers in Tehran continue to carry out wrestling training while affected by skin infections.Cauliflower ear "is common among wrestlers in Tehran.More research is needed to investigate hearing loss as a possible side effect of either cauliflower ear or ear injury in wrestling in Iran.

  16. The path of a click stimulus from ear canal to umbo.

    PubMed

    Milazzo, Mario; Fallah, Elika; Carapezza, Michael; Kumar, Nina S; Lei, Jason H; Olson, Elizabeth S

    2017-03-01

    The tympanic membrane (TM) has a key role in transmitting sounds to the inner ear, but a concise description of how the TM performs this function remains elusive. This paper probes TM operation by applying a free field click stimulus to the gerbil ear and exploring the consequent motions of the TM and umbo. Motions of the TM were measured both on radial tracks starting close to the umbo and on a grid distal and adjacent to the umbo. The experimental results confirmed the high fidelity of sound transmission from the ear canal to the umbo. A delay of 5-15 μs was seen in the onset of TM motion between points just adjacent to the umbo and mid-radial points. The TM responded with a ringing motion, with different locations possessing different primary ringing frequencies. A simple analytic model from the literature, treating the TM as a string, was used to explore the experimental results. The click-based experiments and analysis led to the following description of TM operation: A transient sound pressure on the TM causes a transient initial TM motion that is maximal ∼ at the TM's radial midpoints. Mechanical forces generated by this initial prominent TM distortion then pull the umbo inward, leading to a delayed umbo response. The initial TM deformation also gives rise to prolonged mechanical ringing on the TM that does not result in significant umbo motion, likely due to destructive interference from the range of ringing frequencies. Thus, the umbo's response is a high-fidelity representation of the transient stimulus. Because any sound can be considered as a consecutive series of clicks, this description is applicable to any sound stimulus. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Knowledge, Attitude and Practice of Ear Care in Coastal Karnataka.

    PubMed

    Dosemane, Deviprasad; Ganapathi, Keerthan; Kanthila, Jayashree

    2015-12-01

    Ear as an organ is necessary for the perception of sound and body balance. Ear infection, diabetes mellitus, hypertension and excessive use of mobile phone for listening to music at high volume all can reduce hearing. No earlier study was available in the costal Karnataka population, regarding the practice of ear care. The study objective was to ascertain the level of knowledge of the community regarding ear care, to find out whether some of the common conditions affecting hearing are known and to find out the common practices involved in maintaining ear hygiene. This cross-sectional study was conducted on 500 subjects in two tertiary care hospitals by convenient sampling, using self-administered questionnaire. Knowledge, Attitude and Practice across the age groups, religion & education background were studied. Across different education groups, 66.7%-90% did not know that 'cold' can cause ear infection and 46.7%-75.0% did not know that diabetes and hypertension can reduce hearing. When there is ear pain or discharge, people put ear drops available at home in 48.3%-75.0% across 3 age groups; 58.5%-61.5% across 3 religions and 44.8%-67.9% across 5 education groups. No statistically significant difference was found in the practice of pouring oil into ears across religions. A total of 58.6%-100% daily clean inside the ear and 70-100% use cotton buds. General perception of the people is that ear is necessary only for hearing. Majority did not know that nasal infection can affect the ear and that DM and hypertension can cause hearing loss. When there is ear pain and discharge, most of the adults put drops that are available at home. Pouring oil into the ears and cleaning inside the ear canals is routinely practiced in costal Karnataka.

  18. Major evolutionary transitions and innovations: the tympanic middle ear

    PubMed Central

    2017-01-01

    One of the most amazing transitions and innovations during the evolution of mammals was the formation of a novel jaw joint and the incorporation of the original jaw joint into the middle ear to create the unique mammalian three bone/ossicle ear. In this review, we look at the key steps that led to this change and other unusual features of the middle ear and how developmental biology has been providing an understanding of the mechanisms involved. This starts with an overview of the tympanic (air-filled) middle ear, and how the ear drum (tympanic membrane) and the cavity itself form during development in amniotes. This is followed by an investigation of how the ear is connected to the pharynx and the relationship of the ear to the bony bulla in which it sits. Finally, the novel mammalian jaw joint and versatile dentary bone will be discussed with respect to evolution of the mammalian middle ear. This article is part of the themed issue ‘Evo-devo in the genomics era, and the origins of morphological diversity’. PMID:27994124

  19. Identifying position, visibility, dimensions, and angulation of the ear.

    PubMed

    Mohamed, Kasim; Christian, Jayanth; Jeyapalan, Karthigeyan; Natarajan, Shanmuganathan; Banu, Fathima; Veeravalli, Padmanabhan T

    2014-01-01

    We selected 254 subjects between the ages of 18 and 30 yr to assess the ear position, angulations of the ear in relation to the nose, visibility from the frontal view, and dimensions of the ear by using various anthropometric points of the face. Subjects were divided into four groups based on facial form. A reference plane indicator, facial topographical measurements, metal ruler, and digital photography were used. While considering the position of the ear, in all facial forms except square tapering, the most samples showed a tendency for the subaurale being in line with subnasale. Regression analysis showed a tendency to gnathion distance is the most dependent variable with length of the ear kept as a constant predictor, while both interalar distance and exocanthion to endocanthion distance correlate highly significantly to the width of the ear. In all subjects, the visibility of the ear when viewed from the front was an average of 1.5 mm. Regardless of facial form, ear angulation was generally less than nose angulation.

  20. Nonsurgical correction of congenital ear abnormalities in the newborn: Case series.

    PubMed

    Smith, Wg; Toye, Jw; Reid, A; Smith, Rw

    2005-07-01

    To determine whether a simple, nonsurgical treatment for congenital ear abnormalities (lop-ear, Stahl's ear, protruding ear, cryptotia) improved the appearance of ear abnormalities in newborns at six weeks of age. This is a descriptive case series. All newborns with identified abnormalities were referred by their family physician to one paediatrician (WGS) in a small level 2 perinatal centre. The ears were waxed and taped in a standard manner within 10 days of birth. Pictures were taken before taping and at the end of taping (one month). All patients and pictures were assessed by one plastic surgeon (JWT) at six weeks of age and scored using a standard scoring system. A telephone survey of the nontreatment group was conducted. The total number of ears assessed was 90. Of this total, 69 ears were taped and fully evaluated in the study (77%). The refusal rate was 23%. In the treatment group, 59% had lop-ear, 19% had Stahl's ear, 17% had protruding ear and 3% had cryptotia. Overall correction (excellent/improved) for the treatment group was 90% (100% for lop-ear, 100% for Stahl's ear, 67% for protruding ear and 0% for cryptotia). In the nontreatment (refusal) group, 67% of the ears failed to correct spontaneously. No complications were recognized by the authors or parents by six weeks. The percentage of newborns in one year in the perinatal centre with recognized ear abnormalities was 6% (90 of 1600). A simple, nonsurgical treatment in a Caucasian population appeared to be very effective in correcting congenital ear abnormalities with no complications and high patient/parent satisfaction.

  1. [Basics of Ear Surgery].

    PubMed

    Lailach, S; Zahnert, T

    2016-12-01

    The present article about the basics of ear surgery is a short overview of current indications, the required diagnostics and surgical procedures of common otologic diseases. In addition to plastic and reconstructive surgery of the auricle, principles of surgery of the external auditory canal, basics of middle ear surgery and the tumor surgery of the temporal bone are shown. Additionally, aspects of the surgical hearing rehabilitation (excluding implantable hearing systems) are presented considering current study results. Georg Thieme Verlag KG Stuttgart · New York.

  2. Tomographic imaging using poissonian detector data

    DOEpatents

    Aspelmeier, Timo; Ebel, Gernot; Hoeschen, Christoph

    2013-10-15

    An image reconstruction method for reconstructing a tomographic image (f.sub.j) of a region of investigation within an object (1), comprises the steps of providing detector data (y.sub.i) comprising Poisson random values measured at an i-th of a plurality of different positions, e.g. i=(k,l) with pixel index k on a detector device and angular index l referring to both the angular position (.alpha..sub.l) and the rotation radius (r.sub.l) of the detector device (10) relative to the object (1), providing a predetermined system matrix A.sub.ij assigning a j-th voxel of the object (1) to the i-th detector data (y.sub.i), and reconstructing the tomographic image (f.sub.j) based on the detector data (y.sub.i), said reconstructing step including a procedure of minimizing a functional F(f) depending on the detector data (y.sub.i) and the system matrix A.sub.ij and additionally including a sparse or compressive representation of the object (1) in an orthobasis T, wherein the tomographic image (f.sub.j) represents the global minimum of the functional F(f). Furthermore, an imaging method and an imaging device using the image reconstruction method are described.

  3. High-throughput method for ear phenotyping and kernel weight estimation in maize using ear digital imaging.

    PubMed

    Makanza, R; Zaman-Allah, M; Cairns, J E; Eyre, J; Burgueño, J; Pacheco, Ángela; Diepenbrock, C; Magorokosho, C; Tarekegne, A; Olsen, M; Prasanna, B M

    2018-01-01

    Grain yield, ear and kernel attributes can assist to understand the performance of maize plant under different environmental conditions and can be used in the variety development process to address farmer's preferences. These parameters are however still laborious and expensive to measure. A low-cost ear digital imaging method was developed that provides estimates of ear and kernel attributes i.e., ear number and size, kernel number and size as well as kernel weight from photos of ears harvested from field trial plots. The image processing method uses a script that runs in a batch mode on ImageJ; an open source software. Kernel weight was estimated using the total kernel number derived from the number of kernels visible on the image and the average kernel size. Data showed a good agreement in terms of accuracy and precision between ground truth measurements and data generated through image processing. Broad-sense heritability of the estimated parameters was in the range or higher than that for measured grain weight. Limitation of the method for kernel weight estimation is discussed. The method developed in this work provides an opportunity to significantly reduce the cost of selection in the breeding process, especially for resource constrained crop improvement programs and can be used to learn more about the genetic bases of grain yield determinants.

  4. EARS: Electronic Access to Reference Service.

    PubMed Central

    Weise, F O; Borgendale, M

    1986-01-01

    Electronic Access to Reference Service (EARS) is a front end to the Health Sciences Library's electronic mail system, with links to the online public catalog. EARS, which became operational in September 1984, is accessed by users at remote sites with either a terminal or microcomputer. It is menu-driven, allowing users to request: a computerized literature search, reference information, a photocopy of a journal article, or a book. This paper traces the history of EARS and discusses its use, its impact on library staff and services, and factors that influence the diffusion of new technology. PMID:3779167

  5. A break-even analysis of major ear surgery.

    PubMed

    Wasson, J D; Phillips, J S

    2015-10-01

    To determine variables which affect cost and profit for major ear surgery and perform a break-even analysis. Retrospective financial analysis. UK teaching hospital. Patients who underwent major ear surgery under general anaesthesia performed by the senior author in main theatre over a 2-year period between dates of 07 September 2010 and 07 September 2012. Income, cost and profit for each major ear patient spell. Variables that affect major ear surgery profitability. Seventy-six patients met inclusion criteria. Wide variation in earnings, with a median net loss of £-1345.50 was observed. Income was relatively uniform across all patient spells; however, theatre time of major ear surgery at a cost of £953.24 per hour varied between patients and was the main determinant of cost and profit for the patient spell. Bivariate linear regression of earnings on theatre time identified 94% of variation in earnings was due to variation in theatre time (r = -0.969; P < 0.0001) and derived a break-even time for major ear surgery of 110.6 min. Theatre time was dependent on complexity of procedure and number of OPCS4 procedures performed, with a significant increase in theatre time when three or more procedures were performed during major ear surgery (P = 0.015). For major ear surgery to either break-even or return a profit, total theatre time should not exceed 110 min and 36 s. © 2015 John Wiley & Sons Ltd.

  6. Rehabilitation of a missing ear with an implant retained auricular prosthesis

    PubMed Central

    Guttal, Satyabodh Sheshraj; Shanbhag, Shruti; Kulkarni, Sudhindra S.; Thakur, Srinath L.

    2015-01-01

    Burns can leave a patient with a severely debilitating disability even after treatment. The objectives of burn rehabilitation are to minimize the adverse effects caused by the injury while rehabilitating the patient's physical and psychological well-being, maximizing social integration. Long-term success of maxillofacial prostheses mainly depends on the retention. Extra oral implant retained prostheses have proved to be a predictable treatment option for maxillofacial rehabilitation. Replacement of a severely deformed external ear with burned tissues may be satisfactorily accomplished by a cosmetic prosthesis anchored by implants integrated in the skull. The use of such implants is now a well-recognized method for creating a stable result in maxillofacial rehabilitation. This case report describes a safe, simple and economical method for the rehabilitation of a patient with missing right auricle using an implant supported silicone prosthesis. The implant was placed in the mastoid region of the temporal bone. Reconstruction of the ear was done with auricular silicone prosthesis, retained using magnets incorporated in an autopolymerizing resin shim to decrease the weight of the prosthesis on a single implant. This method eliminates the need of tedious laboratory procedures and exact casting and fitting requirements of a metal substructure while minimizing the overall weight and cost of the prosthesis while maintaining adequate support, esthetics and retention of the prosthesis. PMID:26929490

  7. Middle Ear Pressures in Wind Instrument Musicians.

    PubMed

    Osborne, Max Sallis; Morris, Simon; Clark, Matthew P; Begg, Philip

    2018-05-22

    This study aimed to assess if playing wind instruments leads to a measurable increase in middle ear pressure during note generation and to provide evidence to clinicians to advise musicians undergoing middle ear surgery. An observational cohort study of 40 volunteers in 7 different wind instrument categories underwent tympanometry at rest and during note production. Community. Recreational musicians aged over 18 years recruited from the student body attending Birmingham University, UK. None. Tympanometry is used as a noninvasive measure of middle ear pressure. The pressure at which peak compliance occurred was taken as an indirect measure of middle ear pressure. The data produced at rest and during note production was statistically analysed with paired t testing and significance set at a p value less than 0.01. Overall a statistically significant increase in middle ear pressure change of 0.63 mm Hg (p = 0.0001) during note production was identified. Musicians playing the oboe and trumpet demonstrate the largest increase in middle ear pressure of 1.46 mm Hg (p = 0.0053) and 0.78 mm Hg (p = 0.0005) respectively. The data provided by this study gives evidence for the first time that playing wind instruments does increase middle ear pressure. Although the clinical significance of this is yet to be determined the authors would advise that musicians who undergo otological procedures should refrain from playing their instruments until full recovery has been achieved as advised by their clinician following direct microscopic review.

  8. Seperating Long-term Hydrological Loading and Tectonic Deformation Observed with Multi-temporal SAR Interferometry and GPS in Qinghai-Tibetan Plateau

    NASA Astrophysics Data System (ADS)

    LI, G.; Lin, H.

    2014-12-01

    essential parameter for loading effect simulation, and our simulation gave the similar Young's Modulus as the previous seismic tomographic INDEPTH III program did. Therefore with accurate seismic tomographic results and loading history detected by remote sensing could accurately simulate ground deformation caused by hydrological loading.

  9. Learning to perform ear reconstruction.

    PubMed

    Wilkes, Gordon H

    2009-08-01

    Learning how to perform ear reconstruction is very difficult. There are no standardized teaching methods. This has resulted in many ear reconstructions being suboptimal. Learning requires a major commitment by the surgeon. Factors to be seriously considered by those considering performing this surgery are (1) commitment, (2) aptitude, (3) training methods available, (4) surgical skills and experience, and (5) additional equipment needs. Unless all these factors are addressed in a surgeon's decision to perform this form of reconstruction, the end result will be compromised, and patient care will not be optimized. It is hoped that considering these factors and following this approach will result in a higher quality of aesthetic result. The future of ear reconstruction lies in the use of advanced digital technologies and tissue engineering. Copyright Thieme Medical Publishers.

  10. Inner ear problems of Thai priest at Priest Hospital.

    PubMed

    Karnchanakas, Taweporn; Tantanavat, Are; Sinsakontavat, Jamjan

    2008-01-01

    The inner ear problems of Thai priest at Priest Hospital had never been reported previously, so Department of Ear Nose Throat try to correlate the metebotic disorder with inner ear problems. 1) To study the fasting blood sugar (FBS), total cholesterol (T. Chol), low density lipoprotein (LDL), and triglyceride (TG), the factors expected to involve in inner ear problems of priests at Priest Hospital. 2) To compare the FBS, T. Chol, HDL, LDL, and TG of priests with inner ear problems at Priest Hospital. 3) To find the percentage of abnormal from FBS, T. Chol, LDL, and TG. The study using 83 sampling of priests with inner ear problems and 107 priests as a controlled group. The research instruments used to collect data was the questionnaire which composed of general information, physical, ear-nose-throat and neurological examination, pure tone audiometry, brainstem evoke response audiometry (BERA) and the blood tests:FBS, T. Chol, TG, and LDL. The inner ear problems were composed of: 1) Dizziness 2) Hearing Loss 3) Tinnitus Aurium. The descriptive statistics were used to analyze the data from questionnaires and utilized frequency, percentage, standard deviation (S.D.) and t-test to achieve desired results. Priest at middle age and elderly with inner ear problems had greater FBS and TG than expected values of the control group. The middle age and elderly priests who had greater FBS and TG than expected values were sick with inner ear problems that causing dizziness, hearing loss and tinnitus aurium.

  11. Evidence for a Right-Ear Advantage in Newborn Hearing Screening Results

    PubMed Central

    Hildesheimer, Minka; Roziner, Ilan; Henkin, Yael

    2016-01-01

    The aim of the present study was to investigate the effect of ear asymmetry, order of testing, and gender on transient-evoked otoacoustic emission (TEOAE) pass rates and response levels in newborn hearing screening. The screening results of 879 newborns, of whom 387 (study group) passed screening successfully in only one ear in the first TEOAE screening, but passed screening successfully in both ears thereafter, and 492 (control group) who passed screening successfully in both ears in the first TEOAE, were retrospectively examined for pass rates and TEOAE characteristics. Results indicated a right-ear advantage, as manifested by significantly higher pass rates in the right ear (61% and 39% for right and left ears, respectively) in the study group, and in 1.75 dB greater TEOAE response amplitudes in the control group. The right-ear advantage was enhanced when the first tested ear was the right ear (76%). When the left ear was tested first, pass rates were comparable in both ears. The right-ear advantage in pass rates was similar in females versus males, but manifested in 1.5 dB higher response amplitudes in females compared with males, regardless of the tested ear and order of testing in both study and control groups. The study provides further evidence for the functional lateralization of the auditory system at the cochlear level already apparent soon after birth in both males and females. While order of testing plays a significant role in the asymmetry in pass rates, the innate right-ear advantage seems to be a more dominant contributor. PMID:27927982

  12. 40 CFR 211.206-1 - Real ear method.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Real ear method. 211.206-1 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.206-1 Real ear method. (a) The value of sound... “Method for the Measurement of Real-Ear Protection of Hearing Protectors and Physical Attenuation of...

  13. 40 CFR 211.206-1 - Real ear method.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Real ear method. 211.206-1 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.206-1 Real ear method. (a) The value of sound... “Method for the Measurement of Real-Ear Protection of Hearing Protectors and Physical Attenuation of...

  14. 40 CFR 211.206-1 - Real ear method.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Real ear method. 211.206-1 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.206-1 Real ear method. (a) The value of sound... “Method for the Measurement of Real-Ear Protection of Hearing Protectors and Physical Attenuation of...

  15. 40 CFR 211.206-1 - Real ear method.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Real ear method. 211.206-1 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.206-1 Real ear method. (a) The value of sound... “Method for the Measurement of Real-Ear Protection of Hearing Protectors and Physical Attenuation of...

  16. 40 CFR 211.206-1 - Real ear method.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Real ear method. 211.206-1 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.206-1 Real ear method. (a) The value of sound... “Method for the Measurement of Real-Ear Protection of Hearing Protectors and Physical Attenuation of...

  17. Ear-body lift and a novel thrust generating mechanism revealed by the complex wake of brown long-eared bats (Plecotus auritus)

    NASA Astrophysics Data System (ADS)

    Johansson, L. Christoffer; Håkansson, Jonas; Jakobsen, Lasse; Hedenström, Anders

    2016-04-01

    Large ears enhance perception of echolocation and prey generated sounds in bats. However, external ears likely impair aerodynamic performance of bats compared to birds. But large ears may generate lift on their own, mitigating the negative effects. We studied flying brown long-eared bats, using high resolution, time resolved particle image velocimetry, to determine the aerodynamics of flying with large ears. We show that the ears and body generate lift at medium to cruising speeds (3-5 m/s), but at the cost of an interaction with the wing root vortices, likely reducing inner wing performance. We also propose that the bats use a novel wing pitch mechanism at the end of the upstroke generating thrust at low speeds, which should provide effective pitch and yaw control. In addition, the wing tip vortices show a distinct spiraling pattern. The tip vortex of the previous wingbeat remains into the next wingbeat and rotates together with a newly formed tip vortex. Several smaller vortices, related to changes in circulation around the wing also spiral the tip vortex. Our results thus show a new level of complexity in bat wakes and suggest large eared bats are less aerodynamically limited than previous wake studies have suggested.

  18. Principles of endoscopic ear surgery.

    PubMed

    Tarabichi, Muaaz; Kapadia, Mustafa

    2016-10-01

    The aim of this review is to study the rationale, limitations, techniques, and long-term outcomes of endoscopic ear surgery. The article discusses the advantages of endoscopic ear surgery in treating cholesteatoma and how the hidden sites like facial recess, sinus tympani, and anterior epitympanum are easily accessed using the endoscope. Transcanal endoscopic approach allows minimally invasive removal of cholesteatoma with results that compare well to traditional postauricular tympanomastoidectomy.

  19. Middle Ear Infection (Chronic Otitis Media) and Hearing Loss

    MedlinePlus

    ... You Middle Ear Infection (Chronic Otitis Media) and Hearing Loss Middle Ear Infection (Chronic Otitis Media) and ... loss. How does otitis media affect a child’s hearing? All children with middle ear infection or fluid ...

  20. Tomographic findings of acute pulmonary toxoplasmosis in immunocompetent patients.

    PubMed

    de Souza Giassi, Karina; Costa, Andre Nathan; Apanavicius, Andre; Teixeira, Fernando Bin; Fernandes, Caio Julio Cesar; Helito, Alfredo Salim; Kairalla, Ronaldo Adib

    2014-11-25

    Toxoplasmosis is one of the most common human zoonosis, and is generally benign in most of the individuals. Pulmonary involvement is common in immunocompromised subjects, but very rare in immunocompetents and there are scarce reports of tomographic findings in the literature. The aim of the study is to describe three immunocompetent patients diagnosed with acute pulmonary toxoplasmosis and their respective thoracic tomographic findings. Acute toxoplasmosis was diagnosed according to the results of serological tests suggestive of recent primary infection and the absence of an alternative etiology. From 2009 to 2013, three patients were diagnosed with acute respiratory failure secondary to acute toxoplasmosis. The patients were two female and one male, and were 38, 56 and 36 years old. Similarly they presented a two-week febrile illness and progressive dyspnea before admission. Laboratory tests demonstrated lymphocytosis, slight changes in liver enzymes and high inflammatory markers. Tomographic findings were bilateral smooth septal and peribronchovascular thickening (100%), ground-glass opacities (100%), atelectasis (33%), random nodules (33%), lymph node enlargement (33%) and pleural effusion (66%). All the patients improved their symptoms after treatment, and complete resolution of tomographic findings were found in the followup. These cases provide a unique description of the presentation and evolution of pulmonary tomographic manifestations of toxoplasmosis in immunocompetent patients. Toxoplasma pneumonia manifests with fever, dyspnea and a non-productive cough that may result in respiratory failure. In animal models, changes were described as interstitial pneumonitis with focal infiltrates of neutrophils that can finally evolve into a pattern of diffuse alveolar damage with focal necrosis. The tomographic findings are characterized as ground glass opacities, smooth septal and marked peribronchovascular thickening; and may mimic pulmonary congestion

  1. Facial asymmetry correction with moulded helmet therapy in infants with deformational skull base plagiocephaly.

    PubMed

    Kreutz, Matthias; Fitze, Brigitte; Blecher, Christoph; Marcello, Augello; Simon, Ruben; Cremer, Rebecca; Zeilhofer, Hans-Florian; Kunz, Christoph; Mayr, Johannes

    2018-01-01

    The recommendation issued by the American Academy of Pediatrics in the early 1990s to position infants on their back during sleep to prevent sudden infant death syndrome (SIDS) has dramatically reduced the number of deaths due to SIDS but has also markedly increased the prevalence of positional skull deformation in infants. Deformation of the base of the skull occurs predominantly in very severe deformational plagiocephaly and is accompanied by facial asymmetry, as well as an altered ear position, called ear shift. Moulded helmet therapy has become an accepted treatment strategy for infants with deformational plagiocephaly. The aim of this study was to determine whether facial asymmetry could be corrected by moulded helmet therapy. In this retrospective, single-centre study, we analysed facial asymmetry of 71 infants with severe deformational plagiocephaly with or without deformational brachycephaly who were undergoing moulded helmet therapy between 2009 and 2013. Computer-assisted, three-dimensional, soft-tissue photographic scanning was used to record the head shape before and after moulded helmet therapy. The distance between two landmarks in the midline of the face (i.e., root of the nose and nasal septum) and the right and left tragus were measured on computer-generated indirect and objective 3D photogrammetry images. A quotient was calculated between the two right- and left-sided distances to the midline. Quotients were compared before and after moulded helmet therapy. Infants without any therapy served as a control group. The median age of the infants before onset of moulded helmet therapy was 5 months (range 3-16 months). The median duration of moulded helmet therapy was 5 months (range 1-16 months). Comparison of the pre- and post-treatment quotients of the left vs. right distances measured between the tragus and root of the nose (n = 71) and nasal septum (n = 71) revealed a significant reduction of the asymmetry (Tragus-Nasion-Line Quotient: 0

  2. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  3. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  4. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  5. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  6. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  7. Three-Dimensional Analysis of the Ear Morphology.

    PubMed

    Modabber, Ali; Galster, Helmut; Peters, Florian; Möhlhenrich, Stephan Christian; Kniha, Kristian; Knobe, Matthias; Hölzle, Frank; Ghassemi, Alireza

    2018-06-01

    For surgical treatment of the face, detailed surgical planning is necessary to avoid later unaesthetic results. Most of the studies in the literature concentrate on the ears' anatomy during childhood and adolescence. Nearly no study evaluates the anatomy of ears of people aged 50 or older. It was our aim to measure and evaluate the ear's anatomy in Caucasians between the ages of 21 and 65. Three-dimensional scans of 240 volunteers were taken. The subjects were divided into groups of males and females and each of them into three groups by age (21-35, 36-50, 51-65). Landmarks were placed in these scans. Distances, relations and angles between them were recorded. The distance between the subaurale and superaurale significantly increases (p < 0.001) during the aging process in males and females. Also, the width of the ear, measured between the preaurale and postaurale, significantly increased (p = 0.007) with advancing age. When the length of the ear is divided into four parts by anatomical landmarks, it extended the most in the lower quadrant with increasing subject age. The ear of Caucasians does not stop changing its shape during adulthood. Even after the body has stopped growing, the ear still does. With the measured values in this study, it should be possible for the surgeon to plan the operation in advance and achieve satisfactory aesthetic outcomes. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  8. Correcting Flank Skin Laxity and Dog Ear Plus Aggressive Liposuction: A Technique for Classic Abdominoplasty in Middle-Eastern Obese Women.

    PubMed

    Hosseini, Seyed Nejat; Ammari, Ali; Mousavizadeh, Seyed Mehdi

    2018-01-01

    Nowadays obesity is a common problem as it leads to abdominal deformation and people's dissatisfaction of their own body. This study has explored using a new surgical technique based on a different incision to reform the flank skin laxity and dog ear plus aggressive liposuction on women with abdominal deformities. From May 2014 to February 2016 , 25 women were chosen for this study. All women had a body mass index more than 28 kg/m 2 , flank folding, bulging and excess fat, abdominal and flank skin sagging and laxity. An important point of the new technique was that the paramedian perforator was preserved. All women were between 33 and 62 years old (mean age of 47±7.2 years old). The average amount of liposuction aspirate was 2,350 mL (1700-3200 mL), and the size of average excised skin ellipse was 23.62×16.08 cm (from 19×15 to 27×18 cm). Dog ear, skin laxity, bulging and fat deposit correction were assessed and scored in two and four months after the surgery. Aggressive abdominal and flank liposuction can be safely done when paramedian perforator is preserved. This has a good cosmetic result in the abdomen and flank and prevents bulging in the incision end and flank. Using this abdominoplasty technique is recommended on patients with high body mass indexes.

  9. Inverse solution of ear-canal area function from reflectance

    PubMed Central

    Rasetshwane, Daniel M.; Neely, Stephen T.

    2011-01-01

    A number of acoustical applications require the transformation of acoustical quantities, such as impedance and pressure that are measured at the entrance of the ear canal, to quantities at the eardrum. This transformation often requires knowledge of the shape of the ear canal. Previous attempts to measure ear-canal area functions were either invasive, non-reproducible, or could only measure the area function up to a point mid-way along the canal. A method to determine the area function of the ear canal from measurements of acoustic impedance at the entrance of the ear canal is described. The method is based on a solution to the inverse problem in which measurements of impedance are used to calculate reflectance, which is then used to determine the area function of the canal. The mean ear-canal area function determined using this method is similar to mean ear-canal area functions measured by other researchers using different techniques. The advantage of the proposed method over previous methods is that it is non- invasive, fast, and reproducible. PMID:22225043

  10. Evidence for a Right-Ear Advantage in Newborn Hearing Screening Results.

    PubMed

    Ari-Even Roth, Daphne; Hildesheimer, Minka; Roziner, Ilan; Henkin, Yael

    2016-12-06

    The aim of the present study was to investigate the effect of ear asymmetry, order of testing, and gender on transient-evoked otoacoustic emission (TEOAE) pass rates and response levels in newborn hearing screening. The screening results of 879 newborns, of whom 387 (study group) passed screening successfully in only one ear in the first TEOAE screening, but passed screening successfully in both ears thereafter, and 492 (control group) who passed screening successfully in both ears in the first TEOAE, were retrospectively examined for pass rates and TEOAE characteristics. Results indicated a right-ear advantage, as manifested by significantly higher pass rates in the right ear (61% and 39% for right and left ears, respectively) in the study group, and in 1.75 dB greater TEOAE response amplitudes in the control group. The right-ear advantage was enhanced when the first tested ear was the right ear (76%). When the left ear was tested first, pass rates were comparable in both ears. The right-ear advantage in pass rates was similar in females versus males, but manifested in 1.5 dB higher response amplitudes in females compared with males, regardless of the tested ear and order of testing in both study and control groups. The study provides further evidence for the functional lateralization of the auditory system at the cochlear level already apparent soon after birth in both males and females. While order of testing plays a significant role in the asymmetry in pass rates, the innate right-ear advantage seems to be a more dominant contributor. © The Author(s) 2016.

  11. Physiological functioning of the ear and masking

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The physiological functions of the ear and the role masking plays in speech communication are examined. Topics under investigation include sound analysis of the ear, the aural reflex, and various types of noise masking.

  12. Diode Laser Ear Piercing: A Novel Technique.

    PubMed

    Suseela, Bibilash Babu; Babu, Preethitha; Chittoria, Ravi Kumar; Mohapatra, Devi Prasad

    2016-01-01

    Earlobe piercing is a common office room procedure done by a plastic surgeon. Various methods of ear piercing have been described. In this article, we describe a novel method of laser ear piercing using the diode laser. An 18-year-old female patient underwent an ear piercing using a diode laser with a power of 2.0 W in continuous mode after topical local anaesthetic and pre-cooling. The diode laser was fast, safe, easy to use and highly effective way of ear piercing. The advantages we noticed while using the diode laser over conventional methods were more precision, minimal trauma with less chances of hypertrophy and keloids, no bleeding with coagulation effect of laser, less time taken compared to conventional method and less chance of infection due to thermal heat effect of laser.

  13. Magnetically driven middle ear ossicles for optical measurement of vibrations in an ear with opened tympanic membrane

    NASA Astrophysics Data System (ADS)

    Peacock, J.; von Unge, M.; Dirckx, J.

    2013-12-01

    Vibrations of the middle ear ossicles are easily measured by means of laser vibrometry. However, laser vibrometry requires free visual access to the object under investigation, and acquiring free visual access to the ossicles through the ear canal requires the removal of the tympanic membrane (TM), with the result that the ossicles can no longer be stimulated acoustically. To overcome this, we devised a new setup in which the ossicles can be driven magnetically. After measuring the response of the TM to an acoustic signal, we then remove it and attach a small magnet to the exposed manubrium (a part of the most lateral auditory ossicle, the malleus, which is normally attached to the TM). An electromagnetic excitation coil is then used to drive the magnet, and the output to the coil adjusted until the vibration of the manubrium, as measured by the vibrometer, matches that measured in response to the acoustic signal. Such a setup may have uses in research on middle ear mechanics, such as the measurement of nonlinearities in their response, as well as applications in the diagnosis of middle ear conditions such as the fixation of the ossicles by otosclerosis or in chronic otitis media. We describe our setup and discuss the viability of our method and its future clinical potential by presenting some measurements on an artificially fixated ear.

  14. Cauliflower Ear and Skin Infections among Wrestlers in Tehran

    PubMed Central

    Kordi, Ramin; Mansournai, Mohammad Ali; Nourian, Roh Allah; Wallace, W. Angus

    2007-01-01

    The purpose of the study was to describe the magnitude of the selected sports medicine problems (i.e. cauliflower ear and skin infections) among wrestlers in Tehran. A number of 411 wrestlers were randomly selected from wrestling clubs in Tehran employing cluster sample setting method. The participants were interviewed using a specially designed and validated questionnaire. Nearly half of the participants (44%) had “cauliflower ears”. Only 23% of these participants had received any kind of treatment for their acute ear haematomas that are known to result in “cauliflower ears”. The prevalence of reported hearing loss among participants with cauliflower ears (11.5%, 95%CI: 6.9 to 16.2) was significantly more than this prevalence among those participants without cauliflower ears (1.8%, 95%CI: 0.1 to 3.5) (p < 0.05). More than half of the participants (52%) had skin infection diagnosed by a physician during the previous year. This study has identified evidence of an increase in hearing loss as a possible side effect of either cauliflower ear or ear injury in wrestling in Iran. There has been an outbreak of ringworm and there is a significant potential for an outbreak of impetigo among wrestlers in Tehran. Key points Skin infections are prevalent among wrestlers in Tehran. Commonly wrestlers in Tehran continue to carry out wrestling training while affected by skin infections. Cauliflower ear ”is common among wrestlers in Tehran. More research is needed to investigate hearing loss as a possible side effect of either cauliflower ear or ear injury in wrestling in Iran. PMID:24198702

  15. Can you hear me now? Understanding vertebrate middle ear development

    PubMed Central

    Chapman, Susan Caroline

    2010-01-01

    The middle ear is a composite organ formed from all three germ layers and the neural crest. It provides the link between the outside world and the inner ear, where sound is transduced and routed to the brain for processing. Extensive classical and modern studies have described the complex morphology and origin of the middle ear. Non-mammalian vertebrates have a single ossicle, the columella. Mammals have three functionally equivalent ossicles, designated the malleus, incus and stapes. In this review, I focus on the role of genes known to function in the middle ear. Genetic studies are beginning to unravel the induction and patterning of the multiple middle ear elements including the tympanum, skeletal elements, the air-filled cavity, and the insertion point into the inner ear oval window. Future studies that elucidate the integrated spatio-temporal signaling mechanisms required to pattern the middle ear organ system are needed. The longer-term translational benefits of understanding normal and abnormal ear development will have a direct impact on human health outcomes. PMID:21196256

  16. Precise individualized armature for ear reconstruction

    NASA Astrophysics Data System (ADS)

    Evenhouse, Raymond J.; Chen, Xiaoming

    1991-04-01

    The cosmetic result of an ear restored surgically or via prosthetics is dependent on the surgeon''s ability to carve a precise cartilage armature at the time of surgery or the prosthetist''s ability to sculpt in wax an exact duplicate of the patient''s " missing" ear. Introducing CAD/CAM technology into the process benefits the esthetic outcome of these procedures. By utilizing serial section information derived from CAT MRI or moulage techniques a mirrorimage of the patient''s " donor" ear is generated. The resulting earform data is then used for the design of a cartilage armature produced by multi-axis milling or to produce by stereolithography a model which serves as the basis for a prosthesis.

  17. Building an endoscopic ear surgery program.

    PubMed

    Golub, Justin S

    2016-10-01

    This article discusses background, operative details, and outcomes of endoscopic ear surgery. This information will be helpful for those establishing a new program. Endoscopic ear surgery is growing in popularity. The ideal benefit is in totally transcanal access that would otherwise require a larger incision. The endoscope carries a number of advantages over the microscope, as well as some disadvantages. Several key maneuvers can minimize disadvantages. There is a paucity of studies directly comparing outcomes between endoscopic and microscopic approaches for the same procedure. The endoscope is gaining acceptance as a tool for treating otologic diseases. For interested surgeons, this article can help bridge the transition from microscopic to totally transcanal endoscopic ear surgery for appropriate disease.

  18. Tomographic Imaging of a Forested Area By Airborne Multi-Baseline P-Band SAR.

    PubMed

    Frey, Othmar; Morsdorf, Felix; Meier, Erich

    2008-09-24

    In recent years, various attempts have been undertaken to obtain information about the structure of forested areas from multi-baseline synthetic aperture radar data. Tomographic processing of such data has been demonstrated for airborne L-band data but the quality of the focused tomographic images is limited by several factors. In particular, the common Fourierbased focusing methods are susceptible to irregular and sparse sampling, two problems, that are unavoidable in case of multi-pass, multi-baseline SAR data acquired by an airborne system. In this paper, a tomographic focusing method based on the time-domain back-projection algorithm is proposed, which maintains the geometric relationship between the original sensor positions and the imaged target and is therefore able to cope with irregular sampling without introducing any approximations with respect to the geometry. The tomographic focusing quality is assessed by analysing the impulse response of simulated point targets and an in-scene corner reflector. And, in particular, several tomographic slices of a volume representing a forested area are given. The respective P-band tomographic data set consisting of eleven flight tracks has been acquired by the airborne E-SAR sensor of the German Aerospace Center (DLR).

  19. Playing by Ear: Foundation or Frill?

    ERIC Educational Resources Information Center

    Woody, Robert H.

    2012-01-01

    Many people divide musicians into two types: those who can read music and those who play by ear. Formal music education tends to place great emphasis on producing musically literate performers but devotes much less attention to teaching students to make music without notation. Some would suggest that playing by ear is a specialized skill that is…

  20. Continuous long-term measurements of the middle ear pressure in subjects without a history of ear disease.

    PubMed

    Tideholm, B; Carlborg, B; Jönsson, S; Bylander-Groth, A

    1998-06-01

    A new method was used for continuous measurement of the middle ear (ME) pressure during a 24-h period. In 10 subjects without a history of ear disease a small perforation was made through the tympanic membrane. A tight rubber stopper containing a small polyethylene tube was fitted into the external ear canal. Conventional tubal function tests were performed. The equipment was then carried by the subjects for 24 h of normal activity to monitor any slow or rapid dynamic pressure change in the ME. Body position was found to be the most important factor affecting ME pressure variation, during the 24-h continuous pressure measurements. A significant pressure rise occurred in the recumbent position in all but one subject. Few rapid pressure equilibrations were seen during the recordings, indicating few tubal openings. This implies that the pressure changes in the ME seen in this study were mainly the result of gas exchange over the mucosa. The investigation might be a base for reference when investigating different kinds of pathologic conditions in the ear.

  1. Anisotropic yield function capable of predicting eight ears

    NASA Astrophysics Data System (ADS)

    Yoon, J. H.; Cazacu, O.

    2011-08-01

    Deep drawing of a cylindrical cup from a rolled sheet is one of the typical forming operations where the effect of this anisotropy is most evident. Indeed, it is well documented in the literature that the number of ears and the shape of the earing pattern correlate with the r-values profile. For the strongly textured aluminum alloy AA 5042 (Numisheet Benchmark 2011), the experimental r-value distribution has two minima between the rolling and transverse direction data provided for this show that the r-value along the transverse direction (TD) is five times larger than the value corresponding to the rolling direction. Therefore, it is expected that there are more that the earing profile has more than four ears. The main objective of this paper is to assess whether a new form of CPB06ex2 yield function (Plunkett et al. (2008)) tailored for metals with no tension-compression asymmetry is capable of predicting more than four ears for this material.

  2. Inner ear abnormalities in patients with Goldenhar syndrome.

    PubMed

    Bisdas, Sotirios; Lenarz, Minoo; Lenarz, Thomas; Becker, Hartmut

    2005-05-01

    The objective of this study is to investigate the inner ear malformations in patients with Goldenhar syndrome and to hypothesize the potential embryopathogenesis of these malformations. Retrospective case review. Tertiary referral center. Fourteen patients with Goldenhar syndrome. Each patient underwent hearing tests and high-resolution computed tomography (CT) of the temporal bone. In six patients, magnetic resonance imaging of the temporal bone also was performed. Among the 14 patients with Goldenhar syndrome, 13 had outer and middle ear anomalies and 5 (36%) had inner ear malformations, including one case of common cavity. Our observations regarding inner ear anomalies in Goldenhar syndrome correlate with the reported cases in the literature and may help to hypothesize the embryological origin of these malformations, which can caused by an early developmental arrest in the fourth gestational week. Specialists evaluating patients with Goldenhar syndrome should be aware of the possibility of inner ear malformations, which could be diagnosed earlier with appropriate imaging studies.

  3. Cosmetic ear surgery

    MedlinePlus

    ... ear reduction. In: Rubin JP, Neligan PC, eds. Plastic Surgery: Volume 2: Aesthetic Surgery . 4th ed. Philadelphia, ... Tang Ho, MD, Assistant Professor, Division of Facial Plastic and Reconstructive Surgery, Department of Otolaryngology – Head and ...

  4. Ear infection - acute

    MedlinePlus

    ... more than 6 children) Changes in altitude or climate Cold climate Exposure to smoke Family history of ear infections ... Clinical Assistant Professor of Pediatrics, University of Washington School of Medicine, Seattle, WA. Internal review and update ...

  5. Earfold Implantable Clip System for Correction of Prominent Ears: Analysis of Safety in 403 Patients

    PubMed Central

    Sojitra, Nilesh; Glumicic, Sinisa; Vlok, Jacobus A.; O’Toole, Greg; Hannan, S. Alam; Sabbagh, Walid

    2018-01-01

    Background: The Earfold system, a new treatment for the correction of prominent ears, consists of 3 components: the Earfold implant, the Earfold introducer, and the Prefold positioner. Methods: This is an interim report based on an ongoing analysis of safety in a series of patients treated for prominent ears with the Earfold implant between February 2013 and September 2014. Safety was assessed based on adverse event reports and the need for implant revision; follow-up is ongoing. Results: Seven surgeons used 1,200 Earfold implants to treat 403 patients (ages, 7–70 years; 63% male); the time since the initial implant procedure now ranges from 30 to 48 months. To date, 145 patients (36%) have returned for a follow-up visit (mean, 7.7 months [range, 1–34 months]). Adverse events requiring intervention have affected 39 of 403 (9.7%) patients; these include implant revisions (n = 17 [4.2%], most often due to implant visibility), skin erosion over the implant (n = 15 [3.7%]), and infection (n = 7 [1.7%]). Bleeding, recurrence of prominence, hematoma, deformity, or adverse scarring did not occur. Conclusions: This interim analysis has shown that Earfold prominent ear correction system is associated with relatively few adverse events that require intervention; a small number of patients experienced infection, implant extrusion, or implant visibility that required revision. Most adverse events were related to either patient selection or technical errors at implantation. It is expected that with continued use of Earfold by surgeons experienced in otoplasty, the adverse event incidence will decrease. PMID:29464160

  6. Continuous 24-hour measurement of middle ear pressure.

    PubMed

    Tideholm, B; Jönsson, S; Carlborg, B; Welinder, R; Grenner, J

    1996-07-01

    A new method was developed for continuous measurement of the middle ear pressure during a 24-h period. The equipment consisted of a piezo-electric pressure device and a digital memory. To allow continuous pressure recordings during normal every-day activities the equipment was made light and portable. The measurement accuracy of the equipment as well as the base-line and temperature stability were tested and found to meet to our requirements satisfactorily. In 4 volunteers with different middle ear conditions, a small perforation was made through the tympanic membrane. A rubber stopper containing a small polyethylene tube was fitted into the external ear canal. Tubal function tests were made to establish the equipment's ability to monitor fast pressure changes. The tests were well in accordance with other methods of direct pressure measurements. The equipment was carried by the volunteers for 24 h to monitor any slow or rapid dynamic pressure changes in the middle ear. Four continuous 24-h measurements are presented. The method was found to be suitable for valid measurements of dynamic pressure changes in the middle ear during normal every-day activities. It may become a useful instrument in the search for a better understanding of the development of chronic middle ear disease.

  7. Tomographic inversion of satellite photometry. II

    NASA Technical Reports Server (NTRS)

    Solomon, S. C.; Hays, P. B.; Abreu, V. J.

    1985-01-01

    A method for combining nadir observations of emission features in the upper atmosphere with the result of a tomographic inversion of limb brightness measurements is presented. Simulated and actual results are provided, and error sensitivity is investigated.

  8. Mapping local deformation behavior in single cell metal lattice structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlton, Holly D.; Lind, Jonathan; Messner, Mark C.

    The deformation behavior of metal lattice structures is extremely complex and challenging to predict, especially since strain is not uniformly distributed throughout the structure. Understanding and predicting the failure behavior for these types of light-weighting structures is of great interest due to the excellent scaling of stiffness- and strength-to weight ratios they display. Therefore, there is a need to perform simplified experiments that probe unit cell mechanisms. This study reports on high resolution mapping of the heterogeneous structural response of single unit cells to the macro-scale loading condition. Two types of structures, known to show different stress-strain responses, were evaluatedmore » using synchrotron radiation micro-tomography while performing in-situ uniaxial compression tests to capture the local micro-strain deformation. These structures included the octet-truss, a stretch-dominated lattice, and the rhombic-dodecahedron, a bend-dominated lattice. The tomographic analysis showed that the stretch- and bend-dominated lattices exhibit different failure mechanisms and that the defects built into the structure cause a heterogeneous localized deformation response. Also shown here is a change in failure mode for stretch-dominated lattices, where there appears to be a transition from buckling to plastic yielding for samples with a relative density between 10 and 20%. In conclusion, the experimental results were also used to inform computational studies designed to predict the mesoscale deformation behavior of lattice structures. Here an equivalent continuum model and a finite element model were used to predict both local strain fields and mechanical behavior of lattices with different topologies.« less

  9. Mapping local deformation behavior in single cell metal lattice structures

    DOE PAGES

    Carlton, Holly D.; Lind, Jonathan; Messner, Mark C.; ...

    2017-02-08

    The deformation behavior of metal lattice structures is extremely complex and challenging to predict, especially since strain is not uniformly distributed throughout the structure. Understanding and predicting the failure behavior for these types of light-weighting structures is of great interest due to the excellent scaling of stiffness- and strength-to weight ratios they display. Therefore, there is a need to perform simplified experiments that probe unit cell mechanisms. This study reports on high resolution mapping of the heterogeneous structural response of single unit cells to the macro-scale loading condition. Two types of structures, known to show different stress-strain responses, were evaluatedmore » using synchrotron radiation micro-tomography while performing in-situ uniaxial compression tests to capture the local micro-strain deformation. These structures included the octet-truss, a stretch-dominated lattice, and the rhombic-dodecahedron, a bend-dominated lattice. The tomographic analysis showed that the stretch- and bend-dominated lattices exhibit different failure mechanisms and that the defects built into the structure cause a heterogeneous localized deformation response. Also shown here is a change in failure mode for stretch-dominated lattices, where there appears to be a transition from buckling to plastic yielding for samples with a relative density between 10 and 20%. In conclusion, the experimental results were also used to inform computational studies designed to predict the mesoscale deformation behavior of lattice structures. Here an equivalent continuum model and a finite element model were used to predict both local strain fields and mechanical behavior of lattices with different topologies.« less

  10. Large-scale tomographic particle image velocimetry using helium-filled soap bubbles

    NASA Astrophysics Data System (ADS)

    Kühn, Matthias; Ehrenfried, Klaus; Bosbach, Johannes; Wagner, Claus

    2011-04-01

    To measure large-scale flow structures in air, a tomographic particle image velocimetry (tomographic PIV) system for measurement volumes of the order of one cubic metre is developed, which employs helium-filled soap bubbles (HFSBs) as tracer particles. The technique has several specific characteristics compared to most conventional tomographic PIV systems, which are usually applied to small measurement volumes. One of them is spot lights on the HFSB tracers, which slightly change their position, when the direction of observation is altered. Further issues are the large particle to voxel ratio and the short focal length of the used camera lenses, which result in a noticeable variation of the magnification factor in volume depth direction. Taking the specific characteristics of the HFSBs into account, the feasibility of our large-scale tomographic PIV system is demonstrated by showing that the calibration errors can be reduced down to 0.1 pixels as required. Further, an accurate and fast implementation of the multiplicative algebraic reconstruction technique, which calculates the weighting coefficients when needed instead of storing them, is discussed. The tomographic PIV system is applied to measure forced convection in a convection cell at a Reynolds number of 530 based on the inlet channel height and the mean inlet velocity. The size of the measurement volume and the interrogation volumes amount to 750 mm × 450 mm × 165 mm and 48 mm × 48 mm × 24 mm, respectively. Validation of the tomographic PIV technique employing HFSBs is further provided by comparing profiles of the mean velocity and of the root mean square velocity fluctuations to respective planar PIV data.

  11. Tomographic diffractive microscopy with a wavefront sensor.

    PubMed

    Ruan, Y; Bon, P; Mudry, E; Maire, G; Chaumet, P C; Giovannini, H; Belkebir, K; Talneau, A; Wattellier, B; Monneret, S; Sentenac, A

    2012-05-15

    Tomographic diffractive microscopy is a recent imaging technique that reconstructs quantitatively the three-dimensional permittivity map of a sample with a resolution better than that of conventional wide-field microscopy. Its main drawbacks lie in the complexity of the setup and in the slowness of the image recording as both the amplitude and the phase of the field scattered by the sample need to be measured for hundreds of successive illumination angles. In this Letter, we show that, using a wavefront sensor, tomographic diffractive microscopy can be implemented easily on a conventional microscope. Moreover, the number of illuminations can be dramatically decreased if a constrained reconstruction algorithm is used to recover the sample map of permittivity.

  12. Fgf8 and Fgf3 are required for zebrafish ear placode induction, maintenance and inner ear patterning.

    PubMed

    Léger, Sophie; Brand, Michael

    2002-11-01

    The vertebrate inner ear develops from initially 'simple' ectodermal placode and vesicle stages into the complex three-dimensional structure which is necessary for the senses of hearing and equilibrium. Although the main morphological events in vertebrate inner ear development are known, the genetic mechanisms controlling them are scarcely understood. Previous studies have suggested that the otic placode is induced by signals from the chordamesoderm and the hindbrain, notably by fibroblast growth factors (Fgfs) and Wnt proteins. Here we study the role of Fgf8 as a bona-fide hindbrain-derived signal that acts in conjunction with Fgf3 during placode induction, maintenance and otic vesicle patterning. Acerebellar (ace) is a mutant in the fgf8 gene that results in a non-functional Fgf8 product. Homozygous mutants for acerebellar (ace) have smaller ears that typically have only one otolith, abnormal semi-circular canals, and behavioral defects. Using gene expression markers for the otic placode, we find that ace/fgf8 and Fgf-signaling are required for normal otic placode formation and maintenance. Conversely, misexpression of fgf8 or Fgf8-coated beads implanted into the vicinity of the otic placode can increase ear size and marker gene expression, although competence to respond to the induction appears restricted. Cell transplantation experiments and expression analysis suggest that Fgf8 is required in the hindbrain in the rhombomere 4-6 area to restore normal placode development in ace mutants, in close neighbourhood to the forming placode, but not in mesodermal tissues. Fgf3 and Fgf8 are expressed in hindbrain rhombomere 4 during the stages that are critical for placode induction. Joint inactivation of Fgf3 and Fgf8 by mutation or antisense-morpholino injection causes failure of placode formation and results in ear-less embryos, mimicking the phenotype we observe after pharmacological inhibition of Fgf-signaling. Fgf8 and Fgf3 together therefore act during induction

  13. Morphological Variations and Biometrics of Ear: An Aid to Personal Identification.

    PubMed

    Verma, Pradhuman; Sandhu, Harpreet Kaur; Verma, Kanika Gupta; Goyal, Sharry; Sudan, Madhu; Ladgotra, Amit

    2016-05-01

    The morphological characteristics and dimensions of external ear vary in different human ethnic races which can be utilized in forensics for personal identification of living or deceased. To determine uniqueness of morphological and biometric variations of both ears for individualization among North East (NE) and North West (NW) subpopulation of India. The study was conducted on randomly selected 80 students, 40 from each subgroup. Nine ear parameters were recorded twice using digital Vernier's caliper by single investigator and two indices (Ear Index and Lobule Index) were calculated for both the ears. Morphological ear shapes and lobule attachment were also noted. Pearson's coefficient correlation test was performed on cross-tabulations to evaluate significant relationship between different variables. Of the total 35% free and 65% attached ear lobes were noted in both population groups. Oval ear shape was most commonly noted followed by triangular, rectangular and round in both populations. On comparing anthropometric measurements of ears in two populations it was found that except the tragus length and lobule index all other values were noted more in NW population. No statistical difference was found in ear and lobular indices of males and females although the left ear index and lobule index were found to be higher than right in both populations except in NW females where right lobule index was recorded more than left. The results obtained can be used in anthropological and forensic sciences for the inclusion and exclusion of persons for identification on the basis of ear variations.

  14. Comparison of Middle Ear Visualization With Endoscopy and Microscopy.

    PubMed

    Bennett, Marc L; Zhang, Dongqing; Labadie, Robert F; Noble, Jack H

    2016-04-01

    The primary goal of chronic ear surgery is the creation of a safe, clean dry ear. For cholesteatomas, complete removal of disease is dependent on visualization. Conventional microscopy is adequate for most dissection, but various subregions of the middle ear are better visualized with endoscopy. The purpose of the present study was to quantitatively assess the improved visualization that endoscopes afford as compared with operating microscopes. Microscopic and endoscopic views were simulated using a three-dimensional model developed from temporal bone scans. Surface renderings of the ear canal and middle ear subsegments were defined and the percentage of visualization of each middle ear subsegment, both with and without ossicles, was then determined for the microscope as well as for 0-, 30-, and 45-degree endoscopes. Using this information, we analyzed which mode of visualization is best suited for dissection within a particular anatomical region. Using a 0-degree scope provides significantly more visualization of every subregion, except the antrum, compared with a microscope. In addition, angled scopes permit visualizing significantly more surface area of every subregion of the middle ear than straight scopes or microscopes. Endoscopes offer advantages for cholesteatoma dissection in difficult-to-visualize areas including the sinus tympani and epitympanum.

  15. INNER EAR EMBRYOGENESIS: GENETIC AND ENVIRONMENTAL DETERMINANTS

    EPA Science Inventory

    The anatomy and developmental molecular genetics of the inner ear from establishment of the otic placode to formation of the definitive cochlea and vestibular apparatus will be reviewed and the complex 3-D structural changes that shape the developing inner ear will be illustrated...

  16. Ear-protector ratings.

    DOT National Transportation Integrated Search

    1973-12-01

    Twenty-one brands of ear protectors, including custom-molded, wearer-molded, and pre-molded types, were evaluated according to American-standard procedures. Earplugs are described and are listed in the order of their low-frequency (below 1000 Hz) att...

  17. Human ear detection in the thermal infrared spectrum

    NASA Astrophysics Data System (ADS)

    Abaza, Ayman; Bourlai, Thirimachos

    2012-06-01

    In this paper the problem of human ear detection in the thermal infrared (IR) spectrum is studied in order to illustrate the advantages and limitations of the most important steps of ear-based biometrics that can operate in day and night time environments. The main contributions of this work are two-fold: First, a dual-band database is assembled that consists of visible and thermal profile face images. The thermal data was collected using a high definition middle-wave infrared (3-5 microns) camera that is capable of acquiring thermal imprints of human skin. Second, a fully automated, thermal imaging based ear detection method is developed for real-time segmentation of human ears in either day or night time environments. The proposed method is based on Haar features forming a cascaded AdaBoost classifier (our modified version of the original Viola-Jones approach1 that was designed to be applied mainly in visible band images). The main advantage of the proposed method, applied on our profile face image data set collected in the thermal-band, is that it is designed to reduce the learning time required by the original Viola-Jones method from several weeks to several hours. Unlike other approaches reported in the literature, which have been tested but not designed to operate in the thermal band, our method yields a high detection accuracy that reaches ~ 91.5%. Further analysis on our data set yielded that: (a) photometric normalization techniques do not directly improve ear detection performance. However, when using a certain photometric normalization technique (CLAHE) on falsely detected images, the detection rate improved by ~ 4%; (b) the high detection accuracy of our method did not degrade when we lowered down the original spatial resolution of thermal ear images. For example, even after using one third of the original spatial resolution (i.e. ~ 20% of the original computational time) of the thermal profile face images, the high ear detection accuracy of our method

  18. Torsion of partial cleft of ear lobule.

    PubMed

    Kumaraswamy, M; Waiker, Veena P

    2014-02-01

    Torsion is a well-known phenomenon involving organs with long mesentery. Torsion in the ear lobule is rare. Ear lobule is very well vascularized. In cases of partial cleft ear lobule, there is a small segment of lobule inferior to the cleft which is vascularized through the pedicles on either side of the cleft. A lady aged 89 years presented with discoloration of the ear lobule. She was diagnosed as having gangrene of the central part of lobule. The segment of the lobule had undergone more than 360° torsion. She underwent debridement of gangrenous part and lobuloplasty. In our case laxity of the stretched lobule caused the torsion of the segment followed by gangrene. This rare complication indicates the need for correction of the cleft lobule not only for esthetic purpose, but also for the prevention of torsion. Copyright © 2013 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  19. Middle ear abnormalities in Van Maldergem syndrome.

    PubMed

    Verheij, Emmy; Thomeer, Henricus G X M; Pameijer, Frank A; Topsakal, Vedat

    2017-01-01

    Van Maldergem syndrome (VMS) is a very rare syndrome that was first described in 1992. The main features of this syndrome comprise intellectual disability, blepharo-naso-facial malformation, and hand anomalies. Almost all nine described patients have been shown to be affected by conductive hearing impairment attributed to microtia, and atresia of the outer ear canal. Here, we present a VMS patient with congenital malformations of the middle ear as the main reason for severe conductive bilateral hearing impairment. To our knowledge, this is the first report to describe middle ear abnormalities in VMS. These malformations were seen on high resolution Computed Tomography scanning and during an exploratory tympanotomy. Due to the severity of the middle ear abnormalities and the risk for facial nerve damage, the patient was not offered an ossicular chain reconstruction but a bone conduction device after this exploratory tympanotomy. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  20. Complex deformation in western Tibet revealed by anisotropic tomography

    NASA Astrophysics Data System (ADS)

    Zhang, Heng; Zhao, Junmeng; Zhao, Dapeng; Yu, Chunquan; Liu, Hongbing; Hu, Zhaoguo

    2016-10-01

    The mechanism and pattern of deformation beneath western Tibet are still an issue of debate. In this work we present 3-D P- and S-wave velocity tomography as well as P-wave radial and azimuthal anisotropy along the ANTILOPE-I profile and surrounding areas in western Tibet, which are determined by using a large number of P and S arrival-time data of local earthquakes and teleseismic events. Our results show that low-velocity (low-V) zones exist widely in the middle crust, whereas low-V zones are only visible in the lower crust beneath northwestern Tibet, indicating the existence of significant heterogeneities and complex flow there. In the upper mantle, a distinct low-V gap exists between the Indian and Asian plates. Considering the P- and S-wave tomography and P-wave azimuthal and radial anisotropy results, we interpret the gap to be caused mainly by shear heating. Depth-independent azimuthal anisotropy and high-velocity zones exist beneath the northern part of the study region, suggesting a vertically coherent deformation beneath the Tarim Basin. In contrast, tomographic and anisotropic features change with depth beneath the central and southern parts of the study region, which reflects depth-dependent (or decoupled) deformations there. At the northern edge of the Indian lithospheric mantle (ILM), P-wave azimuthal anisotropy shows a nearly east-west fast-velocity direction, suggesting that the ILM was re-built by mantle materials flowing to the north.

  1. 15 CFR 734.2 - Important EAR terms and principles.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... technology and software not subject to the EAR are described in §§ 734.7 through 734.11 and supplement no. 1... of items subject to the EAR out of the United States, or release of technology or software subject to... source code and object code software subject to the EAR. (2) Export of technology or software. (See...

  2. 15 CFR 734.2 - Important EAR terms and principles.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... technology and software not subject to the EAR are described in §§ 734.7 through 734.11 and supplement no. 1... of items subject to the EAR out of the United States, or release of technology or software subject to... source code and object code software subject to the EAR. (2) Export of technology or software. (See...

  3. 15 CFR 734.2 - Important EAR terms and principles.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... technology and software not subject to the EAR are described in §§ 734.7 through 734.11 and supplement no. 1... of items subject to the EAR out of the United States, or release of technology or software subject to... source code and object code software subject to the EAR. (2) Export of technology or software. (See...

  4. 15 CFR 734.2 - Important EAR terms and principles.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... technology and software not subject to the EAR are described in §§ 734.7 through 734.11 and supplement no. 1... of items subject to the EAR out of the United States, or release of technology or software subject to... source code and object code software subject to the EAR. (2) Export of technology or software. (See...

  5. 15 CFR 734.2 - Important EAR terms and principles.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... technology and software not subject to the EAR are described in §§ 734.7 through 734.11 and supplement no. 1... of items subject to the EAR out of the United States, or release of technology or software subject to... source code and object code software subject to the EAR. (2) Export of technology or software. (See...

  6. Ear Aesthetics: Investigation by the Use of an Online Viral Survey.

    PubMed

    Steele, Jessica; Farmer, Eleanor; O'Hara, Justine; Bulstrode, Neil

    2017-03-01

    The ear is a key facial feature and yet few studies have previously assessed ear aesthetics. This study aimed to assess the anatomical components of the ear that have the greatest impact on the perception of ear aesthetics. Three photographs of a male adult ear (close-up, lateral, posterior) were digitally manipulated such that in each, 1 anatomical element of the ear was either enlarged or reduced. A complete set of 16 photographs including a repeat of the original ear as a control were randomized and entered into an online survey that required respondents to rate the attractiveness of each ear on a scale of 1 (least attractive) to 10 (most attractive). The survey was disseminated using email and social media. A total of 248 responses were received, 155 women and 92 men. Respondents were grouped by demographics of age and occupation. Reducing (R) or enlarging (E) the helix (R, P = 0.0256; E, P = 0.003), concha (R, P = 0.0002; E, P = <0.0001) and lobule (R, P = 0.0006; E, P < 0.0001) had a significant effect on ratings of attractiveness. Altering the tragus had no significant effect (R, P = 0.448; E, P = 0.201). In lateral view, raising the height of the ear had a significant effect (P = <0.0001) but not in lowering the height (P = 0.3038). Increasing and decreasing the projection of the ears both had a significant effect (P < 0.0001). The results of this study have provided useful evidence regarding the anatomical components of the ear that have the greatest effect on ear aesthetics. Furthermore, this study has proven the usefulness of conducting research using viral online surveys.

  7. Vitamin D receptor deficiency impairs inner ear development in zebrafish

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kwon, Hye-Joo; Biology Department, Princess Nourah University, Riyadh 11671

    The biological actions of vitamin D are largely mediated through binding to the vitamin D receptor (VDR), a member of the nuclear hormone receptor family, which regulates gene expression in a wide variety of tissues and cells. Mutations in VDR gene have been implicated in ear disorders (hearing loss and balance disorder) but the mechanisms are not well established. In this study, to investigate the role of VDR in inner ear development, morpholino-mediated gene knockdown approaches were used in zebrafish model system. Two paralogs for VDR, vdra and vdrb, have been identified in zebrafish. Knockdown of vdra had no effectmore » on ear development, whereas knockdown of vdrb displayed morphological ear defects including smaller otic vesicles with malformed semicircular canals and abnormal otoliths. Loss-of-vdrb resulted in down-regulation of pre-otic markers, pax8 and pax2a, indicating impairment of otic induction. Furthermore, zebrafish embryos lacking vdrb produced fewer sensory hair cells in the ears and showed disruption of balance and motor coordination. These data reveal that VDR signaling plays an important role in ear development. - Highlights: • VDR signaling is involved in ear development. • Knockdown of vdrb causes inner ear malformations during embryogenesis. • Knockdown of vdrb affects otic placode induction. • Knockdown of vdrb reduces the number of sensory hair cells in the inner ear. • Knockdown of vdrb disrupts balance and motor coordination.« less

  8. The Existence of a Natural Plica at the Anatomical Base of the Antihelix and its Surgical Importance to Address Protruding Ears: An Anatomicosurgical Study.

    PubMed

    Oliveira, Miguel Marques; Oliveira, Daniel Sousa Marques; Oliveira, Gustavo Sousa Marques

    2017-04-01

    Protruding ears represent the main abnormality of the external ear, which has required numerous anatomic and surgical studies. Most studies give attention to the absence of the antihelix as the anatomic defect responsible for the clinical deformity of the lateral aspect of the ear that leads to its anteversion. The reason for this study is the controversial origin of the fold of the antihelix within the auricle framework, a field of interest for aesthetic otoplasty. The current study examined the medial surface of the cartilaginous ear frame from cadaver specimens with right morphology to investigate the starting point of the fold of the antihelix. This allowed for verification of a natural plica at the anatomic base of this antihelical fold, which to date has not had its topography described morphologically. It is acknowledged that relevant literature makes no reference to this innominate natural plica at the origin of the antihelix, whose anatomic and surgical importance is related in this report. This study aimed to show that the existence of a natural plica at the base of the antihelix in ear framing represents a landmark between normal and protruding ear morphology. For 8 years, 118 ears were carefully investigated within rigid ethical principles based on a thorough review of the pertinent literature. The study investigated 16 selected cadaver specimens and 102 protruding ears dissected by the senior author including 49 bilateral cases (26 males and 23 females) and 4 unilateral cases (2 males and 2 females). Bifacial anthropometric measurements by calipers were used for documentation. A natural plica at the base of the antihelix was found in all cadaver ears selected with right morphology, whereas it was totally absent in every surgically treated protruding ear irrespective of color, gender, age, or ethnic origin. Ambilateral measures of the antihelix eminence certify the study object in normal specimens as well as its lack in abnormal ones. Technical and

  9. [An ear thermometer based on infrared thermopiles sensor].

    PubMed

    Xie, Haiyuan; Qian, Mingli

    2013-09-01

    According to the development of body temperature measurement mode, an ear thermometer with infrared thermopiles sensor is designed for body thermometry Compared with oral thermometer, the accuracy of ear thermometer is acceptable.

  10. Correction of Lying Ears by Augmentation of the Conchoscaphal Angle.

    PubMed

    Kim, Sung-Eun; Yeo, Chi-Ho; Kim, Taegon; Kim, Yong-Ha; Lee, Jun Ho; Chung, Kyu-Jin

    2017-01-01

    Lying ears are defined as ears that protrude less from the head, and in frontal view, are characterized by lateral positioning of antihelical contour relative to the helical rim. These aesthetically displeasing ears require correction in accord with the goals of otoplasty stated by McDowell. The authors present a case of lying ears treated by correcting the conchomastoid angle using Z-plasty, resection of posterior auricular muscle, and correction of the conchoscaphal angle by releasing cartilage using 2 full-thickness incisions and grafting of a conchal cartilage spacer. By combining these techniques, the authors efficiently corrected lying ears and produced aesthetically pleasing results.

  11. Sonographic Measurement of Fetal Ear Length in Turkish Women with a Normal Pregnancy

    PubMed Central

    Özdemir, Mucize Eriç; Uzun, Işıl; Karahasanoğlu, Ayşe; Aygün, Mehmet; Akın, Hale; Yazıcıoğlu, Fehmi

    2014-01-01

    Background: Abnormal fetal ear length is a feature of chromosomal disorders. Fetal ear length measurement is a simple measurement that can be obtained during ultrasonographic examinations. Aims: To develop a nomogram for fetal ear length measurements in our population and investigate the correlation between fetal ear length, gestational age, and other standard fetal biometric measurements. Study Design: Cohort study. Methods: Ear lengths of the fetuses were measured in normal singleton pregnancies. The relationship between gestational age and fetal ear length in millimetres was analysed by simple linear regression. In addition, the correlation of fetal ear length measurements with biparietal diameter, head circumference, abdominal circumference, and femur length were evaluated.Ear length measurements were obtained from fetuses in 389 normal singleton pregnancies ranging between 16 and 28 weeks of gestation. Results: A nomogram was developed by linear regression analysis of the parameters ear length and gestational age. Fetal ear length (mm) = y = (1.348 X gestational age)−12.265), where gestational ages is in weeks. A high correlation was found between fetal ear length and gestational age, and a significant correlation was also found between fetal ear length and the biparietal diameter (r=0.962; p<0.001). Similar correlations were found between fetal ear length and head circumference, and fetal ear length and femur length. Conclusion: The results of this study provide a nomogram for fetal ear length. The study also demonstrates the relationship between ear length and other biometric measurements. PMID:25667783

  12. a Middle-Ear Reverse Transfer Function Computed from Vibration Measurements of Otoacoustic Emissions on the Ear Drum of the Guinea PIG

    NASA Astrophysics Data System (ADS)

    Dalhoff, Ernst; Turcanu, Diana; Gummer, Anthony W.

    2009-02-01

    Using distortion products measured as vibration of the umbo and as sound pressure in the ear canal of guinea pigs, we calculated the corresponding reverse transfer function. We compare the measurements with a middle-ear model taken from the literature and adapted to the guinea pig. A reasonable fit could be achieved. We conclude that the reverse transfer function will be useful to aid fitting a middle-ear model to measured transfer functions of human subjects.

  13. Correcting Flank Skin Laxity and Dog Ear Plus Aggressive Liposuction: A Technique for Classic Abdominoplasty in Middle-Eastern Obese Women

    PubMed Central

    Hosseini, Seyed Nejat; Ammari, Ali; Mousavizadeh, Seyed Mehdi

    2018-01-01

    BACKGROUND Nowadays obesity is a common problem as it leads to abdominal deformation and people’s dissatisfaction of their own body. This study has explored using a new surgical technique based on a different incision to reform the flank skin laxity and dog ear plus aggressive liposuction on women with abdominal deformities. METHODS From May 2014 to February 2016, 25 women were chosen for this study. All women had a body mass index more than 28 kg/m2, flank folding, bulging and excess fat, abdominal and flank skin sagging and laxity. An important point of the new technique was that the paramedian perforator was preserved. RESULTS All women were between 33 and 62 years old (mean age of 47±7.2 years old). The average amount of liposuction aspirate was 2,350 mL (1700-3200 mL), and the size of average excised skin ellipse was 23.62×16.08 cm (from 19×15 to 27×18 cm). Dog ear, skin laxity, bulging and fat deposit correction were assessed and scored in two and four months after the surgery. CONCLUSION Aggressive abdominal and flank liposuction can be safely done when paramedian perforator is preserved. This has a good cosmetic result in the abdomen and flank and prevents bulging in the incision end and flank. Using this abdominoplasty technique is recommended on patients with high body mass indexes. PMID:29651396

  14. Two stage ear/microtia reconstruction using costal cartilage.

    PubMed

    Balaji, S M

    2015-01-01

    Reconstruction of Grade III microtia is a challenging entity in maxillofacial esthetic rehabilitation. Several advocacies and philosophies exist in this field. The aim of the manuscript is to present a single South Indian Experience with Ear reconstruction among South Indian Population. Retrospective analysis of unilateral Grade III microtia reconstruction was performed. Using a set of predefined inclusion and exclusion criteria, the population was selected. Outcome measures in terms of the ear size, auriculocephalic angle, and the conchal depth were measured in the reconstructed and normal side. Descriptive statistics is presented. Twenty-four patients formed the study group and had undergone the classical two-stage reconstruction in a similar fashion. The mean ear size in normal side was 65.8 ± 2.8 mm whereas on the reconstructed side, it was 61.3 ± 5.8 mm. The center's technique achieved above 75% similarity as that of the other normal ear. The mean auriculocephalic angle was 44.6 ± 5.2° whereas for the surgically reconstructed ear, it was 41.9 ± 2.6°. Overall, in these patients, we achieved a 79.94% similarity of auriculocephalic angle in the reconstructed ear as compared to the normal auricle. The conchal depth was 19.2 ± 2.1 mm and 16.6 ± 1.9 mm for normal and reconstructed ear, respectively. In terms of conchal depth, the present study group showed an achievement of 82.88% of accuracy even after a prolonged follow-up. The center employs a classic two stage reconstruction with a customized prosthesis that helps to avoid the loss of projection geometry and minimizes adhesion, infection, and early loss of structural stability.

  15. An in vitro model of murine middle ear epithelium.

    PubMed

    Mulay, Apoorva; Akram, Khondoker M; Williams, Debbie; Armes, Hannah; Russell, Catherine; Hood, Derek; Armstrong, Stuart; Stewart, James P; Brown, Steve D M; Bingle, Lynne; Bingle, Colin D

    2016-11-01

    Otitis media (OM), or middle ear inflammation, is the most common paediatric disease and leads to significant morbidity. Although understanding of underlying disease mechanisms is hampered by complex pathophysiology it is clear that epithelial abnormalities underpin the disease. There is currently a lack of a well-characterised in vitro model of the middle ear (ME) epithelium that replicates the complex cellular composition of the middle ear. Here, we report the development of a novel in vitro model of mouse middle ear epithelial cells (mMECs) at an air-liquid interface (ALI) that recapitulates the characteristics of the native murine ME epithelium. We demonstrate that mMECs undergo differentiation into the varied cell populations seen within the native middle ear. Proteomic analysis confirmed that the cultures secrete a multitude of innate defence proteins from their apical surface. We showed that the mMECs supported the growth of the otopathogen, nontypeable Haemophilus influenzae (NTHi), suggesting that the model can be successfully utilised to study host-pathogen interactions in the middle ear. Overall, our mMEC culture system can help to better understand the cell biology of the middle ear and improve our understanding of the pathophysiology of OM. The model also has the potential to serve as a platform for validation of treatments designed to reverse aspects of epithelial remodelling that underpin OM development. © 2016. Published by The Company of Biologists Ltd.

  16. Are two ears not better than one?

    PubMed

    McArdle, Rachel A; Killion, Mead; Mennite, Monica A; Chisolm, Theresa H

    2012-03-01

    The decision to fit one or two hearing aids in individuals with binaural hearing loss has been debated for years. Although some 78% of U.S. hearing aid fittings are binaural (Kochkin , 2010), Walden and Walden (2005) presented data showing that 82% (23 of 28 patients) of their sample obtained significantly better speech recognition in noise scores when wearing one hearing aid as opposed to two. To conduct two new experiments to fuel the monaural/binaural debate. The first experiment was a replication of Walden and Walden (2005), whereas the second experiment examined the use of binaural cues to improve speech recognition in noise. A repeated measures experimental design. Twenty veterans (aged 59-85 yr), with mild to moderately severe binaurally symmetrical hearing loss who wore binaural hearing aids were recruited from the Audiology Department at the Bay Pines VA Healthcare System. Experiment 1 followed the procedures of the Walden and Walden study, where signal-to-noise ratio (SNR) loss was measured using the Quick Speech-in-Noise (QuickSIN) test on participants who were aided with their current hearing aids. Signal and noise were presented in the sound booth at 0° azimuth under five test conditions: (1) right ear aided, (2) left ear aided, (3) both ears aided, (4) right ear aided, left ear plugged, and (5) unaided. The opposite ear in (1) and (2) was left open. In Experiment 2, binaural Knowles Electronics Manikin for Acoustic Research (KEMAR) manikin recordings made in Lou Malnati's pizza restaurant during a busy period provided a typical real-world noise, while prerecorded target sentences were presented through a small loudspeaker located in front of the KEMAR manikin. Subjects listened to the resulting binaural recordings through insert earphones under the following four conditions: (1) binaural, (2) diotic, (3) monaural left, and (4) monaural right. Results of repeated measures ANOVAs demonstrated that the best speech recognition in noise performance was

  17. Pediatric Obesity and Ear, Nose, and Throat Disorders

    MedlinePlus

    ... Marketplace Find an ENT Doctor Near You Pediatric Obesity and Ear, Nose, and Throat Disorders Pediatric Obesity ... self-esteem, and isolation from their peers. Pediatric obesity and otolaryngic problems Otolaryngologists, or ear, nose, and ...

  18. A comparison of three methods to evaluate the position of an artificial ear on the deficient side of the face from a three-dimensional surface scan of patients with hemifacial microsomia.

    PubMed

    Coward, Trevor J; Watson, Roger M; Richards, Robin; Scott, Brendan J J

    2012-01-01

    Patients with hemifacial microsomia may have a missing ear on the deficient side of the face. The fabrication of an ear for such individuals usually has been accomplished by directly measuring the ear on the normal side to construct a prosthesis based on these dimensions, and the positioning has been, to a large extent, primarily operator-dependent. The aim of the present study was to compare three methods, developed from the identification of landmarks plotted on three-dimensional surface scans, to evaluate the position of an artificial ear on the deficient side of the face compared with the position of the natural ear on the normally developed side. Laser scans were undertaken of the faces of 14 subjects with hemifacial microsomia. Landmarks on the ear and face on the normal side were identified. Three methods of mirroring the normal ear on the deficient side of the face were investigated, which used either facial landmarks from the orbital area or a zero reference point generated from the intersection of three orthogonal planes on a frame of reference. To assess the methods, landmarks were identified on the ear situated on the normal side as well as on the face. These landmarks yielded paired dimensional measurements that could be compared between the normal and deficient sides. Mean differences and 95% confidence intervals were calculated. It was possible to mirror the normal ear image on to the deficient side of the face using all three methods. Generally only small differences between the dimensional measurements on the normal and deficient sides were observed. However, two-way analysis of variance revealed statistically significant differences between the three methods (P = .005). The method of mirroring using the outer canthi was found to result in the smallest dimensional differences between the anthropometric points on the ear and face between the normally developed and deficient sides. However, the effects of the deformity can result in limitations in

  19. The middle ear mass: a rare but important diagnosis.

    PubMed

    Pankhania, Miran; Rourke, Thomas; Draper, Mark R

    2011-12-02

    The authors report a rare case of primary intracranial meningioma presenting as a middle ear mass with conductive hearing loss. The authors aim to highlight the importance of diagnosing a middle ear mass, which although rare, may have a substantial impact on ongoing patient management. A discussion of other middle ear pathologies is made in order to demonstrate the subtle differences in presentation.

  20. Computed tomographic findings in 44 dogs and 10 cats with grass seed foreign bodies.

    PubMed

    Vansteenkiste, D P; Lee, K C L; Lamb, C R

    2014-11-01

    To supplement recent reports of computed tomographic (CT) findings in dogs and cats with grass seed foreign bodies. Retrospective review of cases that had CT scan and subsequent retrieval of a grass seed during the same period of hospitalisation from a site included in the scan. Records of 44 dogs and 10 cats were reviewed. Most were presented in the months July to December. Median duration of clinical signs was 4 weeks (range 2 days to 2 years). The most frequent clinical signs were soft tissue swelling (30% cases), coughing (28%), sneezing (28%) and discharge (26%). Grass seeds were retrieved from the thorax (35% cases), nasal cavity (31%), ear (7%), other sites in the head and neck (22%), sublumbar muscles (2%) and pelvic limb (2%). The grass seed was visible in CT images in 10 (19%) cases. Secondary lesions were visible in CT images of 52 (96%) cases, including collection of exudate (37%), abscess (24%), enlarged lymph nodes (22%) and pulmonary consolidation (20%). CT images appeared normal in 4% animals. Grass seeds within the respiratory tract are frequently visible in CT images, but in general CT appears to be more useful for localisation of secondary lesions than as a method of definite diagnosis. © 2014 British Small Animal Veterinary Association.

  1. Probing the Xenopus laevis inner ear transcriptome for biological function

    PubMed Central

    2012-01-01

    Background The senses of hearing and balance depend upon mechanoreception, a process that originates in the inner ear and shares features across species. Amphibians have been widely used for physiological studies of mechanotransduction by sensory hair cells. In contrast, much less is known of the genetic basis of auditory and vestibular function in this class of animals. Among amphibians, the genus Xenopus is a well-characterized genetic and developmental model that offers unique opportunities for inner ear research because of the amphibian capacity for tissue and organ regeneration. For these reasons, we implemented a functional genomics approach as a means to undertake a large-scale analysis of the Xenopus laevis inner ear transcriptome through microarray analysis. Results Microarray analysis uncovered genes within the X. laevis inner ear transcriptome associated with inner ear function and impairment in other organisms, thereby supporting the inclusion of Xenopus in cross-species genetic studies of the inner ear. The use of gene categories (inner ear tissue; deafness; ion channels; ion transporters; transcription factors) facilitated the assignment of functional significance to probe set identifiers. We enhanced the biological relevance of our microarray data by using a variety of curation approaches to increase the annotation of the Affymetrix GeneChip® Xenopus laevis Genome array. In addition, annotation analysis revealed the prevalence of inner ear transcripts represented by probe set identifiers that lack functional characterization. Conclusions We identified an abundance of targets for genetic analysis of auditory and vestibular function. The orthologues to human genes with known inner ear function and the highly expressed transcripts that lack annotation are particularly interesting candidates for future analyses. We used informatics approaches to impart biologically relevant information to the Xenopus inner ear transcriptome, thereby addressing the

  2. TOmographic Remote Observer of Ionospheric Disturbances

    DTIC Science & Technology

    2007-11-15

    ionosphere . The proposed spacecraft was an evolutionary design from the USUSat, Combat Sentinel, and USUSat II programs whose histories are shown in...Figure 1. The primary science instrument, TOROID for TOmographic Remote Observer of Ionospheric Disturbances, is a photometer for measuring the

  3. Inner Ear Morphology in the Atlantic Molly Poecilia mexicana—First Detailed Microanatomical Study of the Inner Ear of a Cyprinodontiform Species

    PubMed Central

    Schulz-Mirbach, Tanja; Heß, Martin; Plath, Martin

    2011-01-01

    Background Fishes show an amazing diversity in hearing abilities, inner ear structures, and otolith morphology. Inner ear morphology, however, has not yet been investigated in detail in any member of the diverse order Cyprinodontiformes. We, therefore, studied the inner ear of the cyprinodontiform freshwater fish Poecilia mexicana by analyzing the position of otoliths in situ, investigating the 3D structure of sensory epithelia, and examining the orientation patterns of ciliary bundles of the sensory hair cells, while combining μ-CT analyses, scanning electron microscopy, and immunocytochemical methods. P. mexicana occurs in different ecotypes, enabling us to study the intra-specific variability (on a qualitative basis) of fish from regular surface streams, and the Cueva del Azufre, a sulfidic cave in southern Mexico. Results The inner ear of Poecilia mexicana displays a combination of several remarkable features. The utricle is connected rostrally instead of dorso-rostrally to the saccule, and the macula sacculi, therefore, is very close to the utricle. Moreover, the macula sacculi possesses dorsal and ventral bulges. The two studied ecotypes of P. mexicana showed variation mainly in the shape and curvature of the macula lagenae, in the curvature of the macula sacculi, and in the thickness of the otolithic membrane. Conclusions Our study for the first time provides detailed insights into the auditory periphery of a cyprinodontiform inner ear and thus serves a basis—especially with regard to the application of 3D techniques—for further research on structure-function relationships of inner ears within the species-rich order Cyprinodontiformes. We suggest that other poeciliid taxa, or even other non-poeciliid cyprinodontiforms, may display similar inner ear morphologies as described here. PMID:22110746

  4. Inner ear morphology in the Atlantic molly Poecilia mexicana--first detailed microanatomical study of the inner ear of a cyprinodontiform species.

    PubMed

    Schulz-Mirbach, Tanja; Hess, Martin; Plath, Martin

    2011-01-01

    Fishes show an amazing diversity in hearing abilities, inner ear structures, and otolith morphology. Inner ear morphology, however, has not yet been investigated in detail in any member of the diverse order Cyprinodontiformes. We, therefore, studied the inner ear of the cyprinodontiform freshwater fish Poecilia mexicana by analyzing the position of otoliths in situ, investigating the 3D structure of sensory epithelia, and examining the orientation patterns of ciliary bundles of the sensory hair cells, while combining μ-CT analyses, scanning electron microscopy, and immunocytochemical methods. P. mexicana occurs in different ecotypes, enabling us to study the intra-specific variability (on a qualitative basis) of fish from regular surface streams, and the Cueva del Azufre, a sulfidic cave in southern Mexico. The inner ear of Poecilia mexicana displays a combination of several remarkable features. The utricle is connected rostrally instead of dorso-rostrally to the saccule, and the macula sacculi, therefore, is very close to the utricle. Moreover, the macula sacculi possesses dorsal and ventral bulges. The two studied ecotypes of P. mexicana showed variation mainly in the shape and curvature of the macula lagenae, in the curvature of the macula sacculi, and in the thickness of the otolithic membrane. Our study for the first time provides detailed insights into the auditory periphery of a cyprinodontiform inner ear and thus serves a basis--especially with regard to the application of 3D techniques--for further research on structure-function relationships of inner ears within the species-rich order Cyprinodontiformes. We suggest that other poeciliid taxa, or even other non-poeciliid cyprinodontiforms, may display similar inner ear morphologies as described here.

  5. Comparison of packing material in an animal model of middle ear trauma.

    PubMed

    Perez, Enrique; Hachem, Ralph Abi; Carlton, Daniel; Bueno, Isabel; Vernon, Stephen; Van De Water, Thomas R; Angeli, Simon I

    2016-01-01

    To compare the performance of absorbable gelatin sponge (AGS) with polyurethane foam (PUF) as middle ear packing material after mucosal trauma. Using a randomized, controlled and blinded study design fifteen guinea pigs underwent middle ear surgery with mucosal trauma performed on both ears. One ear was packed with either PUF or AGS while the contralateral ear remained untreated and used as non-packed paired controls. Auditory brainstem response (ABR) thresholds were measured pre-operatively and repeated at 1, 2, and 6weeks postoperatively. Histological analysis of middle ear mucosa was done in each group to evaluate the inflammatory reaction and wound healing. Another eighteen animals underwent middle ear wounding and packing in one ear while the contralateral ear was left undisturbed as control. Twelve guinea pigs were euthanized at 2weeks postoperatively, and six were euthanized at 3days post-operatively. Mucosal samples were collected for analysis of TGF-β1 levels by enzyme-linked immunosorbent assay. ABR recordings demonstrate that threshold level changes from baseline were minor in PUF packed and control ears. Threshold levels were higher in the AGS packed ears compared with both control and PUF packed ears for low frequency stimuli. Histological analysis showed persistence of packing material at 6weeks postoperatively, inflammation, granulation tissue formation, foreign body reaction and neo-osteogenesis in both AGS and PUF groups. TGF-β1 protein levels did not differ between groups. PUF and AGS packing cause inflammation and neo-osteogenesis in the middle ear following wounding of the mucosa and packing. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Tomographic Reconstruction from a Few Views: A Multi-Marginal Optimal Transport Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abraham, I., E-mail: isabelle.abraham@cea.fr; Abraham, R., E-mail: romain.abraham@univ-orleans.fr; Bergounioux, M., E-mail: maitine.bergounioux@univ-orleans.fr

    2017-02-15

    In this article, we focus on tomographic reconstruction. The problem is to determine the shape of the interior interface using a tomographic approach while very few X-ray radiographs are performed. We use a multi-marginal optimal transport approach. Preliminary numerical results are presented.

  7. Topical ear drop self-medication practice among the Ear, Nose, and Throat patients in Ido Ekiti, Nigeria: A cross - sectional study.

    PubMed

    Olajide, Toye Gabriel; Aremu, Kayode Shuaib; Esan, Olaide T; Dosunmu, Adepeju Oluwatona; Raji, Mustapha Muhammad

    2018-01-01

    Self-medication is a common habit in our country; Nigeria, especially among patients with otorhinolaryngological disorders. Medication when taken wrongly may bring dire consequences to the individual, such as masking developing diseases and may cause many other undesirable effects. The aim of this study was to determine the prevalence and to analyze topical ear drop self-medication practices among respondents attending the Ear, Nose, and Throat Clinic of Federal Teaching Hospital Ido Ekiti, Nigeria. A 6-month hospital based cross-sectional study was conducted among patients who were seen in the Ear, Nose, and Throat facility of Federal Teaching Hospital, Ido Ekiti from July to December 2016 to determine topical ear drop self-medication practices. A pretested semi-structured questionnaire was used to obtained information from respondents. A total of 162 respondents out of 493 patients seen during the study had otological problems. Of which 107 (66%) respondents had engaged in self-medication with topical ear drops. Their ages ranged between 2 and 83 years with a mean age of 36.6 ± 19.1 years. There were 75 males and 87 females. The major reason for self-medication was that their ailments were minor in about 40.2% and the most common indication for self-medication was ear blockage with hearing impairment (33.6%). Pharmacy/chemist shops (42%) were major sources of information for those that self-medicated. Chloramphenicol and gentamycin were the major drugs that were used by the respondents. Majority of the respondents in this study practiced self-medication using different topical ear drops. Major source of information on the topical ear drops used was from pharmacy/chemist shops. There is a need for adequate public health education to create awareness among people on the danger of self-medication and to enact or enforce the law to reduce access to over the counter drugs. Healthcare should be made available and avoidable at primary health-care level.

  8. Prevalence of external ear disorders in Belgian stray cats.

    PubMed

    Bollez, Anouck; de Rooster, Hilde; Furcas, Alessandra; Vandenabeele, Sophie

    2018-02-01

    Objectives Feline otitis externa is a multifactorial dermatological disorder about which very little is known. The objective of this study was to map the prevalence of external ear canal disorders and the pathogens causing otitis externa in stray cats roaming around the region of Ghent, Belgium. Methods One hundred and thirty stray cats were randomly selected during a local trap-neuter-return programme. All cats were European Shorthairs. This study included clinical, otoscopic and cytological evaluation of both external ears of each cat. Prospective data used as parameters in this study included the sex, age and body condition score of each cat, as well as the presence of nasal and/or ocular discharge, and the results of feline immunodeficiency virus (FIV) and feline leukaemia virus (FeLV) Snap tests. Results Remarkably, very few (sub)clinical problems of the external ear canal were found in the stray cat population. Malassezia species was by far the most common organism found in the external ear canals of the 130 stray cats. A total of 96/130 (74%) cats were found to have Malassezia species organisms present in one or both ears based on the cytological examination. No correlation was found between the parameters of sex, age, body condition score, the presence of nasal and/or ocular discharge and FIV and FeLV status, and the presence of parasites, bacteria or yeasts. Conclusions and relevance This study provides more information about the normal state of the external ear canal of stray cats. The ears of most stray cats are relatively healthy. The presence of Malassezia species organisms in the external ear canal is not rare among stray cats.

  9. Inner ear symptoms and disease: Pathophysiological understanding and therapeutic options

    PubMed Central

    Ciuman, Raphael R.

    2013-01-01

    In recent years, huge advances have taken place in understanding of inner ear pathophysiology causing sensorineural hearing loss, tinnitus, and vertigo. Advances in understanding comprise biochemical and physiological research of stimulus perception and conduction, inner ear homeostasis, and hereditary diseases with underlying genetics. This review describes and tabulates the various causes of inner ear disease and defines inner ear and non-inner ear causes of hearing loss, tinnitus, and vertigo. The aim of this review was to comprehensively breakdown this field of otorhinolaryngology for specialists and non-specialists and to discuss current therapeutic options in distinct diseases and promising research for future therapies, especially pharmaceutic, genetic, or stem cell therapy. PMID:24362017

  10. Sparsity-driven tomographic reconstruction of atmospheric water vapor using GNSS and InSAR observations

    NASA Astrophysics Data System (ADS)

    Heublein, Marion; Alshawaf, Fadwa; Zhu, Xiao Xiang; Hinz, Stefan

    2016-04-01

    An accurate knowledge of the 3D distribution of water vapor in the atmosphere is a key element for weather forecasting and climate research. On the other hand, as water vapor causes a delay in the microwave signal propagation within the atmosphere, a precise determination of water vapor is required for accurate positioning and deformation monitoring using Global Navigation Satellite Systems (GNSS) and Interferometric Synthetic Aperture Radar (InSAR). However, due to its high variability in time and space, the atmospheric water vapor distribution is difficult to model. Since GNSS meteorology was introduced about twenty years ago, it has increasingly been used as a geodetic technique to generate maps of 2D Precipitable Water Vapor (PWV). Moreover, several approaches for 3D tomographic water vapor reconstruction from GNSS-based estimates using the simple least squares adjustment were presented. In this poster, we present an innovative and sophisticated Compressive Sensing (CS) concept for sparsity-driven tomographic reconstruction of 3D atmospheric wet refractivity fields using data from GNSS and InSAR. The 2D zenith wet delay (ZWD) estimates are obtained by a combination of point-wise estimates of the wet delay using GNSS observations and partial InSAR wet delay maps. These ZWD estimates are aggregated to derive realistic wet delay input data of 100 points as if corresponding to 100 GNSS sites within an area of 100 km × 100 km in the test region of the Upper Rhine Graben. The made-up ZWD values can be mapped into different elevation and azimuth angles. Using the Cosine transform, a sparse representation of the wet refractivity field is obtained. In contrast to existing tomographic approaches, we exploit sparsity as a prior for the regularization of the underdetermined inverse system. The new aspects of this work include both the combination of GNSS and InSAR data for water vapor tomography and the sophisticated CS estimation. The accuracy of the estimated 3D water

  11. Gain affected by the interior shape of the ear canal.

    PubMed

    Yu, Jen-Fang; Chen, Yen-Sheng; Cheng, Wei-De

    2011-06-01

    This study investigated the correlation of gain distribution and the interior shape of the human external ear canal. Cross-sectional study of gain measurement at the first bend and second bend. Chang Gung Memorial Hospital and Chang Gung University. There were 15 ears in patients aged between 20 and 30 years (8 men/7 women) with normal hearing and middle ears. Stimulus frequencies of 500, 1000, 2000, 3000, and 4000 Hz were based on the standard clinical hearing test. Measurements closer to the tympanic membrane and the positions at the first and second bends were confirmed by using otoscope. Real ear measurement to analyze the canal resonance in human external ears was adopted. This study found that gain at stimulus frequencies of 4000 Hz was affected by the interior shape of the ear canal (P < .005), particularly at the first and second bends, whereas gain was only affected by the length of the ear canal for stimulus frequencies of 2000 Hz (P < .005). This study found that gain was affected not only by the length of the external auditory canal (EAC) but also by the interior shape of the EAC significantly. The findings of this study may have potential clinical applications in canalplasty and congenital aural atresia surgery and may be used to guide surgeries that attempt to reshape the ear canal to achieve more desirable hearing outcomes.

  12. A review of microvascular ear replantation.

    PubMed

    Jung, Sung Won; Lee, Junsang; Oh, Suk Joon; Koh, Sung Hoon; Chung, Chul Hoon; Lee, Jong Wook

    2013-03-01

    Microvascular ear replantation is a significant challenge because of the small size of the vessels and the fact that traumatic amputations are frequently avulsed. The zone of trauma is therefore extended and the primary repair of the injured vessel is rendered unlikely. The purpose of this study is to review the literature of ear replantation. A review of the relevant literature that has been published since 1980 revealed 47 cases reported in 37 publications. We present 5 cases from our own experience and analyze a total 52 cases of microvascular ear replantation. The patient's age, sex, degree of amputation, cause of injury, ischemic time, method of arterial and venous anastomosis, complications, any additional outflow used, postoperative medications, the requirement for transfusions, and the number of hospital admission days are described. Successful microvascular ear replantations require anastomosis of the vessels if possible. Rather than a vein graft, primary repair of the vessels, or at least pedicled repair of the artery, should be considered to ensure flap survival. In addition, vein repair should be considered if possible to ensure the secure drainage of blood from the replant. With secure circulation, the replant can survive, resulting in a very satisfactory outcome. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Can I Prevent Ear Infections When My Child Swims? (For Parents)

    MedlinePlus

    ... Ear Your Ears Perforated Eardrum What's Earwax? Swimmer's Ear (External ... All information on KidsHealth® is for educational purposes only. For specific medical advice, diagnoses, and treatment, ...

  14. Ear surgery - slideshow

    MedlinePlus

    ... Otolaryngology – Head and Neck Surgery, The University of Texas Medical School at Houston, Houston, TX. Also reviewed by David Zieve, MD, MHA, Medical Director, Brenda Conaway, Editorial Director, and the A.D.A.M. Editorial team. Related MedlinePlus Health Topics Ear Disorders ...

  15. Creating three-dimensional tooth models from tomographic images.

    PubMed

    Lima da Silva, Isaac Newton; Barbosa, Gustavo Frainer; Soares, Rodrigo Borowski Grecco; Beltrao, Maria Cecilia Gomes; Spohr, Ana Maria; Mota, Eduardo Golcalves; Oshima, Hugo Mitsuo Silva; Burnett, Luiz Henrique

    2008-01-01

    The use of Finite Element Analysis (FEA) is becoming very frequent in Dentistry. However, most of the three-dimensional models presented by the literature for teeth are limited in terms of geometry. Discrepancy in shape and dimensions can cause wrong results to occur. Sharp cusps and faceted contour can produce stress concentrations, which are incoherent with the reality. The aim of this study was the processing of tomographic images in order to develop an advanced three-dimensional reconstruction of the anatomy of a molar tooth and the integration of the resulting solid with commercially available CAD/CAE software. Computed tomographic images were obtained from 0.5 mm thick slices of mandibular molar and transferred to commercial cad software. Once the point cloud data have been generated, the work on these points started to get to the solid model of the tooth with Pro/Engineer software. The obtained tooth model showed very accurate shape and dimensions, as it was obtained from real tooth data with error of 0.0 to -0.8 mm. The methodology presented was efficient for creating a biomodel of a tooth from tomographic images that realistically represented its anatomy.

  16. Magnetically driven middle ear ossicles for optical measurement of vibrations in an ear with opened eardrum

    NASA Astrophysics Data System (ADS)

    Peacock, John; Von Unge, Magnus; Dirckx, Joris

    2012-06-01

    Vibrations of the middle ear ossicles are easily measured by means of laser vibrometry. However, exposing the ossicles requires the removal of the eardrum, with the result that the ossicles can no longer be stimulated acoustically. To overcome this we devised a new set up in which the ossicles can be driven magnetically. After measuring the response of the eardrum to an acoustic signal, we then remove the eardrum and attach a small magnet to the exposed manubrium (the part of the first auditory ossicle, the malleus, which is normally attached to the eardrum). An electromagnetic excitation coil is then used to drive the magnet, and the output to the coil adjusted until the vibration of the manubrium, as measured by the vibrometer, matches that measured in response to the acoustic signal. Such a set-up has uses in research on middle ear mechanics, such as the measurement of non-linearities in their response, as well as applications in the diagnosis of middle ear conditions such as the fixation of the ossicles by otosclerosis, or in chronic otitis media. We describe our set up in which the vibrometer unit is attached to a surgical microscope, offering accurate positioning of the laser beam. We discuss the viability of our method and its future potential by presenting some measurements on artificially fixated ears.

  17. Genetic Architecture of Ear Fasciation in Maize (Zea mays) under QTL Scrutiny

    PubMed Central

    Mendes-Moreira, Pedro; Alves, Mara L.; Satovic, Zlatko; dos Santos, João Pacheco; Santos, João Nina; Souza, João Cândido; Pêgo, Silas E.; Hallauer, Arnel R.; Vaz Patto, Maria Carlota

    2015-01-01

    Maize ear fasciation Knowledge of the genes affecting maize ear inflorescence may lead to better grain yield modeling. Maize ear fasciation, defined as abnormal flattened ears with high kernel row number, is a quantitative trait widely present in Portuguese maize landraces. Material and Methods Using a segregating population derived from an ear fasciation contrasting cross (consisting of 149 F2:3 families) we established a two location field trial using a complete randomized block design. Correlations and heritabilities for several ear fasciation-related traits and yield were determined. Quantitative Trait Loci (QTL) involved in the inheritance of those traits were identified and candidate genes for these QTL proposed. Results and Discussion Ear fasciation broad-sense heritability was 0.73. Highly significant correlations were found between ear fasciation and some ear and cob diameters and row number traits. For the 23 yield and ear fasciation-related traits, 65 QTL were identified, out of which 11 were detected in both environments, while for the three principal components, five to six QTL were detected per environment. Detected QTL were distributed across 17 genomic regions and explained individually, 8.7% to 22.4% of the individual traits or principal components phenotypic variance. Several candidate genes for these QTL regions were proposed, such as bearded-ear1, branched silkless1, compact plant1, ramosa2, ramosa3, tasselseed4 and terminal ear1. However, many QTL mapped to regions without known candidate genes, indicating potential chromosomal regions not yet targeted for maize ear traits selection. Conclusions Portuguese maize germplasm represents a valuable source of genes or allelic variants for yield improvement and elucidation of the genetic basis of ear fasciation traits. Future studies should focus on fine mapping of the identified genomic regions with the aim of map-based cloning. PMID:25923975

  18. Downscaling Smooth Tomographic Models: Separating Intrinsic and Apparent Anisotropy

    NASA Astrophysics Data System (ADS)

    Bodin, Thomas; Capdeville, Yann; Romanowicz, Barbara

    2016-04-01

    In recent years, a number of tomographic models based on full waveform inversion have been published. Due to computational constraints, the fitted waveforms are low pass filtered, which results in an inability to map features smaller than half the shortest wavelength. However, these tomographic images are not a simple spatial average of the true model, but rather an effective, apparent, or equivalent model that provides a similar 'long-wave' data fit. For example, it can be shown that a series of horizontal isotropic layers will be seen by a 'long wave' as a smooth anisotropic medium. In this way, the observed anisotropy in tomographic models is a combination of intrinsic anisotropy produced by lattice-preferred orientation (LPO) of minerals, and apparent anisotropy resulting from the incapacity of mapping discontinuities. Interpretations of observed anisotropy (e.g. in terms of mantle flow) requires therefore the separation of its intrinsic and apparent components. The "up-scaling" relations that link elastic properties of a rapidly varying medium to elastic properties of the effective medium as seen by long waves are strongly non-linear and their inverse highly non-unique. That is, a smooth homogenized effective model is equivalent to a large number of models with discontinuities. In the 1D case, Capdeville et al (GJI, 2013) recently showed that a tomographic model which results from the inversion of low pass filtered waveforms is an homogenized model, i.e. the same as the model computed by upscaling the true model. Here we propose a stochastic method to sample the ensemble of layered models equivalent to a given tomographic profile. We use a transdimensional formulation where the number of layers is variable. Furthermore, each layer may be either isotropic (1 parameter) or intrinsically anisotropic (2 parameters). The parsimonious character of the Bayesian inversion gives preference to models with the least number of parameters (i.e. least number of layers, and

  19. Histologic characterization of the cat middle ear: in sickness and in health.

    PubMed

    Sula, M M; Njaa, B L; Payton, M E

    2014-09-01

    The purpose of this study was to establish microscopic normal in the middle ear of the cat while concurrently characterizing gross and microscopic lesions reflecting spontaneous otitis media. Both ears from 50 cats were examined grossly and processed for histologic examination of the external, middle, and internal ear on a single slide. Gross lesions of the middle ear were present in 14 of 100 (14%) and included turbid fluid, frank pus, hemorrhage, and fibrous thickening of the auricular mucoperiosteum. Histologically, 48 of 100 (48%) ears had evidence of ongoing or previous inflammatory middle ear disease, including proteinaceous fluid; vascular ectasia; expansion of the auricular mucoperiosteum by neutrophils, lymphocytes, and macrophages; cholesterol clefts; hemorrhage; fibrin; granulation tissue; membranous pseudo-glands; fibrosis; proliferation and/or osteolysis of the tympanic and septum bullae. Histologic lesions were identified in 34 of 100 ears (34%) lacking gross evidence of disease. Ears were classified histologically as either normal (52/100 [52%]) or diseased (48/100 [48%]). Diseased ears were further classified as mild to moderate (37/100 [37%]) or severely (11/100 [11%]) affected. Internal ear involvement was present in 11 of 100 (11%) ears. Histologic evidence of middle ear disease in cats is far greater than gross lesions or clinical literature suggests; further investigation and correlation of clinical and histologic disease are warranted. With minimal additional preparation, diagnostic specimens may be readily prepared and evaluated for this integral sensing organ. © The Author(s) 2013.

  20. Factors that introduce intrasubject variability into ear-canal absorbance measurements.

    PubMed

    Voss, Susan E; Stenfelt, Stefan; Neely, Stephen T; Rosowski, John J

    2013-07-01

    Wideband immittance measures can be useful in analyzing acoustic sound flow through the ear and also have diagnostic potential for the identification of conductive hearing loss as well as causes of conductive hearing loss. To interpret individual measurements, the variability in test–retest data must be described and quantified. Contributors to variability in ear-canal absorbance–based measurements are described in this article. These include assumptions related to methodologies and issues related to the probe fit within the ear and potential acoustic leaks. Evidence suggests that variations in ear-canal cross-sectional area or measurement location are small relative to variability within a population. Data are shown to suggest that the determination of the Thévenin equivalent of the ER-10C probe introduces minimal variability and is independent of the foam ear tip itself. It is suggested that acoustic leaks in the coupling of the ear tip to the ear canal lead to substantial variations and that this issue needs further work in terms of potential criteria to identify an acoustic leak. In addition, test–retest data from the literature are reviewed.

  1. Modulation by glycyrrhetinic acid derivatives of TPA-induced mouse ear oedema.

    PubMed Central

    Inoue, H.; Mori, T.; Shibata, S.; Koshihara, Y.

    1989-01-01

    1. The anti-inflammatory effects of glycyrrhetinic acid and its derivatives on TPA (12-O-tetradecanoylphorbol-13-acetate)-induced mouse ear oedema were studied. The mechanisms of TPA-induced ear oedema were first investigated with respect to the chemical mediators. 2. The formation of ear oedema reached a maximum 5 h after TPA application (2 micrograms per ear) and the prostaglandin E2 (PGE2) production of mouse ear increased with the oedema formation. 3. TPA-induced ear oedema was prevented by actinomycin D and cycloheximide (0.1 mg per ear, respectively) when applied during 60 min after TPA treatment. 4. Of glycyrrhetinic acid derivatives examined, dihemiphthalate derivatives (IIe, IIe', IIIa, IIIa', IVa, IVa') most strongly inhibited ear oedema on both topical (ID50, 1.6 mg per ear for IIe, 2.0 mg per ear for IIIa and 1.6 mg per ear for IVa) and oral (ID50, 88 mg kg-1 for IIe', 130 mg kg-1 for IIIa' and 92 mg kg-1 for IVa') administration. 5. Glycyrrhetinic acid (Ia) and its derivatives applied 30 min before TPA treatment were much more effective in inhibiting oedema than when applied 30 min after TPA. A dihemiphthalate of triterpenoid compound IVa completely inhibited oedema, even when applied 3 h before TPA treatment. 6. Glycyrrhetinic acid (Ia) and deoxoglycyrrhetol (IIa), the parent compounds, produced little inhibition by oral administration at less than 200 mg kg-1. 7. These results suggest that the dihemiphthalate derivatives of triterpenes derived from glycyrrhetinic acid by chemical modification are useful for the treatment of skin inflammation by both topical and oral application. PMID:2924072

  2. Hierarchical multimodal tomographic x-ray imaging at a superbend

    NASA Astrophysics Data System (ADS)

    Stampanoni, M.; Marone, F.; Mikuljan, G.; Jefimovs, K.; Trtik, P.; Vila-Comamala, J.; David, C.; Abela, R.

    2008-08-01

    Over the last decade, synchrotron-based X-ray tomographic microscopy has established itself as a fundamental tool for non-invasive, quantitative investigations of a broad variety of samples, with application ranging from space research and materials science to biology and medicine. Thanks to the brilliance of modern third generation sources, voxel sizes in the micrometer range are routinely achieved by the major X-ray microtomography devices around the world, while the isotropic 100 nm barrier is reached and trespassed only by few instruments. The beamline for TOmographic Microscopy and Coherent rAdiology experiments (TOMCAT) of the Swiss Light Source at the Paul Scherrer Institut, operates a multimodal endstation which offers tomographic capabilities in the micrometer range in absorption contrast - of course - as well as phase contrast imaging. Recently, the beamline has been equipped with a full field, hard X-rays microscope with a theoretical pixel size down to 30 nm and a field of view of 50 microns. The nanoscope performs well at X-ray energies between 8 and 12 keV, selected from the white beam of a 2.9 T superbend by a [Ru/C]100 fixed exit multilayer monochromator. In this work we illustrate the experimental setup dedicated to the nanoscope, in particular the ad-hoc designed X-ray optics needed to produce a homogeneous, square illumination of the sample imaging plane as well as the magnifying zone plate. Tomographic reconstructions at 60 nm voxel size will be shown and discussed.

  3. Inner-ear decompression sickness: 'hubble-bubble' without brain trouble?

    PubMed

    Tremolizzo, Lucio; Malpieri, Massimo; Ferrarese, Carlo; Appollonio, Ildebrando

    2015-06-01

    Inner-ear decompression sickness (DCS) is an incompletely understood and increasingly recognized condition in compressed-air divers. Previous reports show a high association of inner-ear DCS with persistent foramen ovale (PFO), suggesting that a moderate-to-severe right-to-left shunt might represent a major predisposing factor, and more properly defining it as an event from arterial gas embolism (AGE). However, other conditions characterized by bubbles entering the arterial circulation, such as open-chamber cardiac surgery, do not produce inner-ear involvement, while sometimes damaging the brain extensively. Moreover, in other sites, such as the spinal cord, the prevailing mechanism for DCS is not AGE, but more likely local bubble formation with subsequent compression of venules and capillaries. Thus, AGE might be, more properly, a predisposing condition, neither sufficient, nor possibly even strictly necessary for inner-ear DCS. A 'two-hit hypothesis' has been proposed, implying a locally selective vulnerability of the inner ear to AGE. Modelled kinetics for gas removal are slower in the inner ear compared to the brain, leading to a supersaturated environment which allows bubbles to grow until they eventually obstruct the labyrinthine artery. Since this artery is relatively small, there is a low probability for a bubble to enter it; this might explain the disproportion between the high prevalence of PFO in the general population (25-30%) and the very low incidence of inner-ear DCS in compressed-air diving (approximately 0.005%). Furthermore, given that the labyrinthine artery usually originates either from the anterior inferior cerebellar artery, or directly from the basilar artery, shunting bubbles will more frequently swarm through the entire brain. In this case, however, the brain's much faster gas removal kinetics might allow for them to be reabsorbed without damaging brain tissue. In line with this scenario is the low probability (approx. 15%) of inner-ear

  4. A miniaturized laser-Doppler-system in the ear canal

    NASA Astrophysics Data System (ADS)

    Schmidt, T.; Gerhardt, U.; Kupper, C.; Manske, E.; Witte, H.

    2013-03-01

    Gathering vibrational data from the human middle ear is quite difficult. To this date the well-known acoustic probe is used to estimate audiometric parameters, e.g. otoacoustic emissions, wideband reflectance and the measurement of the stapedius reflex. An acoustic probe contains at least one microphone and one loudspeaker. The acoustic parameter determination of the ear canal is essential for the comparability of test-retest measurement situations. Compared to acoustic tubes, the ear canal wall cannot be described as a sound hard boundary. Sound energy is partly absorbed by the ear canal wall. In addition the ear canal features a complex geometric shape (Stinson and Lawton1). Those conditions are one reason for the inter individual variability in input impedance measurement data of the tympanic membrane. The method of Laser-Doppler-Vibrometry is well described in literature. Using this method, the surface velocity of vibrating bodies can be determined contact-free. Conventional Laser-Doppler-Systems (LDS) for auditory research are mounted on a surgical microscope. Assuming a free line of view to the ear drum, the handling of those laser-systems is complicated. We introduce the concept of a miniaturized vibrometer which is supposed to be applied directly in the ear canal for contact-free measurement of the tympanic membrane surface vibration. The proposed interferometer is based on a Fabry-Perot etalon with a DFB laser diode as light source. The fiber-based Fabry-Perot-interferometer is characterized by a reduced size, compared to e.g. Michelson-, or Mach-Zehnder-Systems. For the determination of the phase difference in the interferometer, a phase generated carrier was used. To fit the sensor head in the ear canal, the required shape of the probe was generated by means of the geometrical data of 70 ear molds. The suggested prototype is built up by a singlemode optical fiber with a GRIN-lens, acting as a fiber collimator. The probe has a diameter of 1.8 mm and a

  5. Experimental Investigation of Compliant Wall Surface Deformation in Turbulent Boundary Layer

    NASA Astrophysics Data System (ADS)

    Wang, Jin; Agarwal, Karuna; Katz, Joseph

    2017-11-01

    On-going research integrates Tomographic PIV (TPIV) with Mach-Zehnder Interferometry (MZI) to measure the correlations between deformation of a compliant wall and a turbulent channel flow or a boundary layer. Aiming to extend the scope to two-way coupling, in the present experiment the wall properties have been designed, based on a theoretical analysis, to increase the amplitude of deformation to several μm, achieving the same order of magnitude as the boundary layer wall unit (5-10 μm). It requires higher speeds and a softer surface that has a Young's modulus of 0.1MPa (vs. 1Mpa before), as well as proper thickness (5 mm) that maximize the wall response to excitation at scales that fall within the temporal and spatial resolution of the instruments. The experiments are performed in a water tunnel extension to the JHU refractive index matched facility. The transparent compliant surface is made of PDMS molded on the tunnel window, and measurements are performed at friction velocity Reynolds numbers in the 1000-7000 range. MZI measures the 2D surface deformation as several magnifications. The time-resolved 3D pressure distribution is determined by calculating to spatial distribution of material acceleration from the TPIV data and integrating it using a GPU-based, parallel-line, omni-directional integration method. ONR.

  6. Tomographic Image Compression Using Multidimensional Transforms.

    ERIC Educational Resources Information Center

    Villasenor, John D.

    1994-01-01

    Describes a method for compressing tomographic images obtained using Positron Emission Tomography (PET) and Magnetic Resonance (MR) by applying transform compression using all available dimensions. This takes maximum advantage of redundancy of the data, allowing significant increases in compression efficiency and performance. (13 references) (KRN)

  7. Ear tube surgery - what to ask your doctor

    MedlinePlus

    What to ask your doctor about ear tube surgery; Tympanostomy - what to ask your doctor; Myringotomy - what to ask your doctor ... need ear tubes? Can we try other treatments? What are the risks of the surgery? Is it ...

  8. Interaction Between Allergy and Middle Ear Infection.

    PubMed

    Oh, Jeong-Hoon; Kim, Woo Jin

    2016-09-01

    Recent studies have attempted to identify interactions among the causes of otitis media with effusion (OME). This review discusses the interaction between allergy and infection with regard to host and environmental factors in terms of the development of OME. Protection of the upper airway against microbial invasion requires active interaction between the defense mechanisms of the respiratory epithelium, including innate and adaptive immunity, and mechanical factors. The impairment of these defenses due to allergy and/or increased bacterial resistance may lead to increased susceptibility to infectious organisms in the respiratory tract and middle ear mucosa. Recent genetic studies have provided valuable information about the association of Toll-like receptor signaling variations with clinical phenotypes and the risk of infection in the middle ear. Among the causal factors of OME, allergy not only induces an inflammatory reaction in the middle ear cavity but also facilitates the invasion of infectious pathogens. There is also evidence that allergy can affect the susceptibility of patients to infection of the upper respiratory tract, including the middle ear cavity.

  9. Local treatment of the inner ear: a study of three different polymers aimed for middle ear administration.

    PubMed

    Engmér Berglin, Cecilia; Videhult Pierre, Pernilla; Ekborn, Andreas; Bramer, Tobias; Edsman, Katarina; Hultcrantz, Malou; Laurell, Göran

    2015-01-01

    A formulation based on sodium hyaluronate (NaHYA) was the most promising candidate vehicle for intra-tympanic drug administration regarding conductive hearing loss, inflammatory reactions, and elimination. Recent advances in inner ear research support the idea of using the middle ear cavity for drug administration to target the inner ear. This paper presents rheological and safety assessments of three candidate polymer formulations for intra-tympanic drug administration. The formulations were based on sodium carboxymethyl cellulose (NaCMC), sodium hyaluronate (NaHYA), and poloxamer 407 (POL). Rheological studies were performed with a controlled rate instrument of the couette type. Safety studies were performed in guinea pigs subjected to an intra-tympanic injection of the formulations. Hearing function was explored with ABR before and 1, 2, and 3 weeks after the injection. Elimination of the formulations marked with coal was explored with an endoscopic digital camera 1, 2, and 3 weeks after injection. Middle and inner ear morphology was examined with light microscopy 6 days after injection. The results speak in favor of NaHYA, since it did not cause prolonged hearing threshold elevations. The results of the elimination and morphological investigations support the conclusion of NaHYA being the most promising candidate for intra-tympanic administration.

  10. Middle ear polyps: results of traction avulsion after a lateral approach to the ear canal in 62 cats (2004-2014).

    PubMed

    Janssens, Sara Ds; Haagsman, Annika N; Ter Haar, Gert

    2017-08-01

    Objectives The objective of this study was to report the surgical outcome and complication rate of deep traction avulsion (TA) of feline aural inflammatory polyps after a lateral approach (LA) to the ear canal. Methods This was a retrospective analysis of data retrieved from an electronic database of 62 cats treated with TA after an LA (TALA) for removal of ear canal polyps. Long-term outcome was assessed via a telephone questionnaire survey with the owners. Results Domestic shorthair cats (48%) and Maine Coons (37%) were over-represented. The most common presenting clinical signs were otorrhoea, ear scratching and head shaking. Video-otoscopic examination confirmed a polypous mass in the ear canal in all patients. All 62 cats underwent TALA, with a mean surgical time of 33 mins for experienced surgeons (n = 4) and 48 mins (n = 12) for less experienced surgeons. The recurrence rate of polyp regrowth for experienced surgeons was 14.3% vs 35% for the less experienced surgeons. Postoperative complications included Horner's syndrome (11.5%) and facial nerve paralysis (3%). Otitis interna was not observed. Conclusions and relevance A lateral approach to the ear canal in combination with deep TA of an aural inflammatory polyp is an effective first-line technique that results in a low recurrence and complication rate.

  11. [Lop ear - knife, tape, or nothing at all?].

    PubMed

    Klockars, Tuomas

    2013-01-01

    More than 200 different surgical techniques of correction of lop ear have been published. The operation is usually recommended to be performed at the age of six years or after. In addition, lop ear surgery involves risks, the most common complications being bleeding, infections, sensory alterations and scarring problems. Surgical preference and decision should always be based on realistic expectations of the patient or the parents, and prior to the decision they should have adequate information about the nature of the procedure and potential complications. Splint therapy of lop ear is possible for infants.

  12. Pressure spectra from single-snapshot tomographic PIV

    NASA Astrophysics Data System (ADS)

    Schneiders, Jan F. G.; Avallone, Francesco; Pröbsting, Stefan; Ragni, Daniele; Scarano, Fulvio

    2018-03-01

    The power spectral density and coherence of temporal pressure fluctuations are obtained from low-repetition-rate tomographic PIV measurements. This is achieved by extension of recent single-snapshot pressure evaluation techniques based upon the Taylor's hypothesis (TH) of frozen turbulence and vortex-in-cell (VIC) simulation. Finite time marching of the measured instantaneous velocity fields is performed using TH and VIC. Pressure is calculated from the resulting velocity time series. Because of the theoretical limitations, the finite time marching can be performed until the measured flow structures are convected out of the measurement volume. This provides a lower limit of resolvable frequency range. An upper limit is given by the spatial resolution of the measurements. Finite time-marching approaches are applied to low-repetition-rate tomographic PIV data of the flow past a straight trailing edge at 10 m/s. Reference results of the power spectral density and coherence are obtained from surface pressure transducers. In addition, the results are compared to state-of-the-art experimental data obtained from time-resolved tomographic PIV performed at 10 kHz. The time-resolved approach suffers from low spatial resolution and limited maximum acquisition frequency because of hardware limitations. Additionally, these approaches strongly depend upon the time kernel length chosen for pressure evaluation. On the other hand, the finite time-marching approaches make use of low-repetition-rate tomographic PIV measurements that offer higher spatial resolution. Consequently, increased accuracy of the power spectral density and coherence of pressure fluctuations are obtained in the high-frequency range, in comparison to the time-resolved measurements. The approaches based on TH and VIC are found to perform similarly in the high-frequency range. At lower frequencies, TH is found to underestimate coherence and intensity of the pressure fluctuations in comparison to time-resolved PIV

  13. Ear abnormalities in patients with oculo-auriculo-vertebral spectrum (Goldenhar syndrome).

    PubMed

    Rosa, Rafael Fabiano Machado; Silva, Alessandra Pawelec da; Goetze, Thayse Bienert; Bier, Bianca de Almeida; Almeida, Sheila Tamanini de; Paskulin, Giorgio Adriano; Zen, Paulo Ricardo Gazzola

    2011-01-01

    Oculo-auriculo-vertebral spectrum (OAVS) is a rare condition characterized by the involvement of the first branchial arches. To investigate the ear abnormalities of a sample of patients with OAVS. The sample consisted of 12 patients with OAVS seen at the Clinical Genetics Unit, UFCSPA/CHSCPA. The study included only patients who underwent mastoid computed tomography and with normal karyotype. We performed a review of its clinical features, giving emphasis to the ear findings. Nine patients were male, the ages ranged from 1 day to 17 years. Ear abnormalities were observed in all patients and involved the external (n = 12), middle (n = 10) and inner ear (n = 3). Microtia was the most frequent finding (n = 12). The most common abnormalities of the middle ear were: opacification (n = 2), displacement (n = 2) and malformation of the ossicular chain. Agenesis of the internal auditory canal (n = 2) was the most frequent alteration of the inner ear. Ear abnormalities are variable in patients with OAVS and often there is no correlation between findings in the external, middle and inner ear. The evaluation of these structures is important in the management of individuals with OAVS.

  14. Mice Haploinsufficient for Ets1 and Fli1 Display Middle Ear Abnormalities and Model Aspects of Jacobsen Syndrome.

    PubMed

    Carpinelli, Marina R; Kruse, Elizabeth A; Arhatari, Benedicta D; Debrincat, Marlyse A; Ogier, Jacqueline M; Bories, Jean-Christophe; Kile, Benjamin T; Burt, Rachel A

    2015-07-01

    E26 transformation-specific 1 (ETS1) and friend leukemia integration 1 (FLI1) are members of the ETS family of transcription factors, of which there are 28 in humans. Both genes are hemizygous in Jacobsen syndrome, an 11q contiguous gene deletion disorder involving thrombocytopenia, facial dysmorphism, growth and mental retardation, malformation of the heart and other organs, and hearing impairment associated with recurrent ear infections. To determine whether any of these defects are because of hemizygosity for ETS1 and FLI1, we characterized the phenotype of mice heterozygous for mutant alleles of Ets1 and Fli1. Fli1(+/-) mice displayed mild thrombocytopenia, as did Ets1(+/-)Fli1(+/-) animals. Fli1(+/-) and Ets1(+/-)Fli1(+/-) mice also displayed craniofacial abnormalities, including a small middle ear cavity, short nasal bone, and malformed interface between the nasal bone process and cartilaginous nasal septum. They exhibited hearing impairment, otitis media, fusions of ossicles to the middle ear wall, and deformed stapes. Hearing impairment was more penetrant and stapes malformations were more severe in Ets1(+/-)Fli1(+/-) mice than in Fli1(+/-) mice, indicating partial functional redundancy of these transcription factors during auditory development. Our findings indicate that the short nose, otitis media, and hearing impairment in Jacobsen syndrome are likely because of hemizygosity for ETS1 and FLI1. Copyright © 2015 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  15. Middle-Ear Pressure Gain and Cochlear Partition Differential Pressure in Chinchilla

    PubMed Central

    Ravicz, Michael E.; Slama, Michaël C.C.; Rosowski, John J.

    2009-01-01

    An important step to describe the effects of inner-ear impedance and pathologies on middle- and inner-ear mechanics is to quantify middle- and inner-ear function in the normal ear. We present middle-ear pressure gain GMEP and trans-cochlear-partition differential sound pressure ΔPCP in chinchilla from 100 Hz to 30 kHz derived from measurements of intracochlear sound pressures in scala vestibuli PSV and scala tympani PST and ear-canal sound pressure near the tympanic membrane PTM. These measurements span the chinchilla's auditory range. GMEP had constant magnitude of about 20 dB between 300 Hz and 20 kHz and phase that implies a 40-μs delay, values with some similarities to previous measurements in chinchilla and other species. ΔPCP was similar to GMEP below about 10 kHz and lower in magnitude at higher frequencies, decreasing to 0 dB at 20 kHz. The high-frequency rolloff correlates with the audiogram and supports the idea that middle-ear transmission limits high-frequency hearing, providing a stronger link between inner-ear macromechanics and hearing. We estimate the cochlear partition impedance ZCP from these and previous data. The chinchilla may be a useful animal model for exploring the effects of nonacoustic inner-ear stimulation such as “bone conduction” on cochlear mechanics. PMID:19945521

  16. Pediatric Obesity and Ear, Nose, and Throat Disorders

    MedlinePlus

    ... Although there is no proven medical link between middle ear infections and pediatric obesity there may be a behavioral association between the two conditions. Some studies have found that when a child is rubbing or massaging the infected ear the ...

  17. Inner ear contribution to bone conduction hearing in the human.

    PubMed

    Stenfelt, Stefan

    2015-11-01

    Bone conduction (BC) hearing relies on sound vibration transmission in the skull bone. Several clinical findings indicate that in the human, the skull vibration of the inner ear dominates the response for BC sound. Two phenomena transform the vibrations of the skull surrounding the inner ear to an excitation of the basilar membrane, (1) inertia of the inner ear fluid and (2) compression and expansion of the inner ear space. The relative importance of these two contributors were investigated using an impedance lumped element model. By dividing the motion of the inner ear boundary in common and differential motion it was found that the common motion dominated at frequencies below 7 kHz but above this frequency differential motion was greatest. When these motions were used to excite the model it was found that for the normal ear, the fluid inertia response was up to 20 dB greater than the compression response. This changed in the pathological ear where, for example, otosclerosis of the stapes depressed the fluid inertia response and improved the compression response so that inner ear compression dominated BC hearing at frequencies above 400 Hz. The model was also able to predict experimental and clinical findings of BC sensitivity in the literature, for example the so called Carhart notch in otosclerosis, increased BC sensitivity in superior semicircular canal dehiscence, and altered BC sensitivity following a vestibular fenestration and RW atresia. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Scanning Thin-Sheet Laser Imaging Microscopy Elucidates Details on Mouse Ear Development

    PubMed Central

    Kopecky, Benjamin; Johnson, Shane; Schmitz, Heather; Santi, Peter; Fritzsch, Bernd

    2016-01-01

    Background The mammalian inner ear is transformed from a flat placode into a three-dimensional (3D) structure with six sensory epithelia that allow for the perception of sound and both linear and angular acceleration. While hearing and balance problems are typically considered to be adult onset diseases, they may arise as a developmental perturbation to the developing ear. Future prevention of hearing or balance loss requires an understanding of how closely genetic mutations in model organisms reflect the human case, necessitating an objective multidimensional comparison of mouse ears with human ears that have comparable mutations in the same gene. Results Here, we present improved 3D analyses of normal murine ears during embryonic development using optical sections obtained through Thin-Sheet Laser Imaging Microscopy. We chronicle the transformation of an undifferentiated otic vesicle between mouse embryonic day 11.5 to a fully differentiated inner ear at postnatal day 15. Conclusions Our analysis of ear development provides new insights into ear development, enables unique perspectives into the complex development of the ear, and allows for the first full quantification of volumetric and linear aspects of ear growth. Our data provide the framework for future analysis of mutant phenotypes that are currently under-appreciated using only two dimensional renderings. PMID:22271591

  19. Scanning thin-sheet laser imaging microscopy elucidates details on mouse ear development.

    PubMed

    Kopecky, Benjamin; Johnson, Shane; Schmitz, Heather; Santi, Peter; Fritzsch, Bernd

    2012-03-01

    The mammalian inner ear is transformed from a flat placode into a three-dimensional (3D) structure with six sensory epithelia that allow for the perception of sound and both linear and angular acceleration. While hearing and balance problems are typically considered to be adult onset diseases, they may arise as a developmental perturbation to the developing ear. Future prevention of hearing or balance loss requires an understanding of how closely genetic mutations in model organisms reflect the human case, necessitating an objective multidimensional comparison of mouse ears with human ears that have comparable mutations in the same gene. Here, we present improved 3D analyses of normal murine ears during embryonic development using optical sections obtained through Thin-Sheet Laser Imaging Microscopy. We chronicle the transformation of an undifferentiated otic vesicle between mouse embryonic day 11.5 to a fully differentiated inner ear at postnatal day 15. Our analysis of ear development provides new insights into ear development, enables unique perspectives into the complex development of the ear, and allows for the first full quantification of volumetric and linear aspects of ear growth. Our data provide the framework for future analysis of mutant phenotypes that are currently under-appreciated using only two dimensional renderings. Copyright © 2012 Wiley Periodicals, Inc.

  20. Medical ultrasonic tomographic system

    NASA Technical Reports Server (NTRS)

    Heyser, R. C.; Lecroissette, D. H.; Nathan, R.; Wilson, R. L.

    1977-01-01

    An electro-mechanical scanning assembly was designed and fabricated for the purpose of generating an ultrasound tomogram. A low cost modality was demonstrated in which analog instrumentation methods formed a tomogram on photographic film. Successful tomogram reconstructions were obtained on in vitro test objects by using the attenuation of the fist path ultrasound signal as it passed through the test object. The nearly half century tomographic methods of X-ray analysis were verified as being useful for ultrasound imaging.

  1. [Advances in genetics of congenital malformation of external and middle ear].

    PubMed

    Wang, Dayong; Wang, Qiuju

    2013-05-01

    Congenital malformation of external and middle ear is a common disease in ENT department, and the incidence of this disease is second only to cleft lip and palate in the whole congenital malformations of the head and face. The external and middle ear malformations may occur separately, or as an important ear symptom of the systemic syndrome. We systematically review and analysis the genetic research progress of congenital malformation of external and middle ear, which would be helpful to understand the mechanism of external and middle ear development, and to provide clues for the further discovery of new virulence genes.

  2. Evolution and development of the vertebrate ear

    NASA Technical Reports Server (NTRS)

    Fritzsch, B.; Beisel, K. W.

    2001-01-01

    This review outlines major aspects of development and evolution of the ear, specifically addressing issues of cell fate commitment and the emerging molecular governance of these decisions. Available data support the notion of homology of subsets of mechanosensors across phyla (proprioreceptive mechanosensory neurons in insects, hair cells in vertebrates). It is argued that this conservation is primarily related to the specific transducing environment needed to achieve mechanosensation. Achieving this requires highly conserved transcription factors that regulate the expression of the relevant structural genes for mechanosensory transduction. While conserved at the level of some cell fate assignment genes (atonal and its mammalian homologue), the ear has also radically reorganized its development by implementing genes used for cell fate assignment in other parts of the developing nervous systems (e.g., neurogenin 1) and by evolving novel sets of genes specifically associated with the novel formation of sensory neurons that contact hair cells (neurotrophins and their receptors). Numerous genes have been identified that regulate morphogenesis, but there is only one common feature that emerges at the moment: the ear appears to have co-opted genes from a large variety of other parts of the developing body (forebrain, limbs, kidneys) and establishes, in combination with existing transcription factors, an environment in which those genes govern novel, ear-related morphogenetic aspects. The ear thus represents a unique mix of highly conserved developmental elements combined with co-opted and newly evolved developmental elements.

  3. Genetic Architecture of Ear Fasciation in Maize (Zea mays) under QTL Scrutiny.

    PubMed

    Mendes-Moreira, Pedro; Alves, Mara L; Satovic, Zlatko; Dos Santos, João Pacheco; Santos, João Nina; Souza, João Cândido; Pêgo, Silas E; Hallauer, Arnel R; Vaz Patto, Maria Carlota

    2015-01-01

    Knowledge of the genes affecting maize ear inflorescence may lead to better grain yield modeling. Maize ear fasciation, defined as abnormal flattened ears with high kernel row number, is a quantitative trait widely present in Portuguese maize landraces. Using a segregating population derived from an ear fasciation contrasting cross (consisting of 149 F2:3 families) we established a two location field trial using a complete randomized block design. Correlations and heritabilities for several ear fasciation-related traits and yield were determined. Quantitative Trait Loci (QTL) involved in the inheritance of those traits were identified and candidate genes for these QTL proposed. Ear fasciation broad-sense heritability was 0.73. Highly significant correlations were found between ear fasciation and some ear and cob diameters and row number traits. For the 23 yield and ear fasciation-related traits, 65 QTL were identified, out of which 11 were detected in both environments, while for the three principal components, five to six QTL were detected per environment. Detected QTL were distributed across 17 genomic regions and explained individually, 8.7% to 22.4% of the individual traits or principal components phenotypic variance. Several candidate genes for these QTL regions were proposed, such as bearded-ear1, branched silkless1, compact plant1, ramosa2, ramosa3, tasselseed4 and terminal ear1. However, many QTL mapped to regions without known candidate genes, indicating potential chromosomal regions not yet targeted for maize ear traits selection. Portuguese maize germplasm represents a valuable source of genes or allelic variants for yield improvement and elucidation of the genetic basis of ear fasciation traits. Future studies should focus on fine mapping of the identified genomic regions with the aim of map-based cloning.

  4. Combined Effect of Fluid and Pressure on Middle Ear Function

    PubMed Central

    Dai, Chenkai; Wood, Mark W.; Gan, Rong Z.

    2008-01-01

    In our previous studies, the effects of effusion and pressure on sound transmission were investigated separately. The aim of this study is to investigate the combined effect of fluid and pressure on middle ear function. An otitis media with effusion model was created by injecting saline solution and air pressure simultaneously into the middle ear of human temporal bones. Tympanic membrane displacement in response to 90 dB SPL sound input was measured by a laser vibrometer and the compliance of the middle ear was measured by a tympanometer. The movement of the tympanic membrane at the umbo was reduced up to 17 dB by the combination of fluid and pressure in the middle ear over the auditory frequency range. The fluid and pressure effects on the umbo movement in the fluid-pressure combination are not additive. The combined effect of fluid and pressure on the umbo movement is different compared with that of only fluid or pressure change in the middle ear. Negative pressure in fluid-pressure combination had more effect on middle ear function than positive pressure. Tympanometry can detect the middle ear pressure of the fluid-pressure combination. This study provides quantitative information for analysis of the combined effect of fluid and pressure on tympanic membrane movement. PMID:18162348

  5. Effects of obstructive sleep apnea surgery on middle ear function.

    PubMed

    Lin, Hsin-Ching; Friedman, Michael; Chang, Hsueh-Wen; Shao, Chi-Hsin; Pulver, Tanya M; Chen, Yung-Che

    2011-04-01

    To study the effect of Z-palatopharyngoplasty plus radiofrequency of the base of the tongue on middle ear function. A retrospective review of a prospective data set at a tertiary care center. University-affiliated medical center. The study population included 47 patients (42 men and 5 women; mean age, 40.8 years) who underwent Z-palatopharyngoplasty plus radiofrequency of the base of the tongue for obstructive sleep apnea/hypopnea syndrome. All patients had healthy eardrums and no previous history of chronic ear disease. Pure-tone audiometric and tympanometric assessments were performed preoperatively and at 3 days, 7 days, 1 month, and 3 months postoperatively. Levels of baseline and postoperative middle ear pressure were compared. Twelve patients (26%) reported otologic concerns, such as ear pressure and/or otalgia, within 1 week postoperatively. No permanent otologic discomfort occurred. A trend toward reduced middle ear pressure was noted in this study. The decrease in middle ear pressure became apparent on day 3. However, mean pressure changes were no longer significantly different than preoperative values by 1 week after surgery. We found that Z-palatopharyngoplasty plus radiofrequency of the base of the tongue for obstructive sleep apnea/hypopnea syndrome induces changes in middle ear function. However, the changes were temporary and not significant after 3 months of follow-up.

  6. Reconstruction of partially amputated external ear with costal cartilage graft: case report.

    PubMed

    Brunelli, A; Bottini, D J; Cervelli, V; Cervelli, G; Grimaldi, M

    2004-06-01

    Many causes are responsible for secondary anomalies of the outer ear, such as: car accidents, sport- or work-related accidents, assaults, bites from animals or humans, benign or malignant tumours, burns and the effects of surgical interventions of the ear (plastic surgery on the ear or attempts at correction of primary malformations of the ear). The anatomical complexity of the ear makes its reconstruction particularly complicated with post-operative results that are often disappointing. The Authors describe their experience in the reconstruction of a partially amputated outer ear following a dog bite. The therapeutic protocol required various surgical stages. Initially, a cutaneous expander was applied at the level of the mastoid in order to ensure a sufficient quantity of local skin. The second stage was to remove cartilage from the ribs, followed by construction of a cartilaginous model of the ear and its insertion into the subcutaneous mastoid region after removal of the cutaneous expander and any residual ear cartilage. The last stage was to separate the neo-formed outer ear from the mastoid skin with the insertion of a cartilage graft to the posterior region of the reconstructed ear. This graft was covered by the occipital fascia rotated at 180 degrees and by a skin graft removed from the pubis. The postoperative result was satisfactory with recuperation of a good aesthetic appearance of the ear. Aim of the present report is to describe the surgical technique employed in the reconstruction of secondary anomalies of the ear and to highlight errors committed during this procedure. These considerations have allowed us to stress some fundamental elements in the reconstruction of the ear. In particular, the watershed was the awareness that we had to create a cartilaginous model that respected, as far as possible, the anatomy of the outer ear with all its ridges, trenches and cavities. This as well as ensuring a sufficient quantity of local skin in order to cover

  7. EAR Program Research Results

    DOT National Transportation Integrated Search

    2013-01-01

    The Exploratory Advanced Research (EAR) Program addresses the need for longer term, higher risk research with the potential for longterm improvements to transportation systems-improvements in planning, building, renewing, and operating safe, congesti...

  8. [Reconstruction of the ear in the burns patient].

    PubMed

    Carrillo-Córdova, Jorge Raúl; Jiménez Murat, Yusef; Apellaniz-Campo, Armando; Bracho-Olvera, Hazel; Carrillo Esper, Raúl

    Face burns are a singular pathology with great functional and psychological impact in the patients suffering them. The ears play a fundamental role in personal interactions and damage to this organ results in physical and emotional distress. The reconstructive treatment of the burned ear is a challenge. Multiple procedures have been described to achieve success in the reconstruction of the burned ear; immediate reconstruction with autologous rib cartilage, secondary reconstruction, alloplastic material reconstruction, tissue expansion, skin grafts and also microvascular flaps are some of the most common procedures used in this patients. All these techniques focus on giving a natural appearance to the patient. Burns to the ears affect 30% of the patients with facial burns, they require an excellent treatment given by a multidisciplinary team. Copyright © 2017 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  9. Missing links in some curious auditory phenomena: a tale from the middle ear.

    PubMed

    Carpenter, Michelle S; Cacace, Anthony T; Mahoney, Marty J

    2012-02-01

    Broadband middle ear power reflectance (BMEPR) is an emerging noninvasive electroacoustic measure that evaluates transmission/reflection properties of the middle ear in high resolution. It is applicable over the entire age continuum and is rapid to perform. However, it remains to be determined if BMEPR is just an incremental step in the evolution of middle ear assessment or a major advance in the way middle ear function can be evaluated. To evaluate effects of age, gender, ear, and frequency on BMEPR measurements in adults without a history of middle ear disease and to assess whether these factors require consideration in test development; to review how these data may influence active physiologic process within the inner ear; to consider how they reconcile with previously published results; and to suggest applications for future research. Prospective, cross-sectional, multivariate analysis to evaluate the effects of age, gender, ear, and frequency on BMEPR in humans without a history of middle ear disease and no air-bone gaps exceeding 10 dB for any frequency. Fifty-six adults in two age groups (Group 1: 18-25 yr, n = 28; Group 2: ≥50 and <66 yr, n = 28). Each age group was stratified by ear and gender in a balanced design. Pure tone air conduction and bone-conduction audiometry was conducted in a commercial sound booth, using a clinical audiometer with standard earphones enclosed in supra-aural ear cushions, and a standard bone-conduction oscillator and headband to evaluate for air-bone gaps. Broadband middle ear power reflectance was measured using a calibrated, commercially available computer-controlled system that incorporated a high quality probe assembly to transduce stimuli and record acoustic responses from the ear canal. Data were analyzed with a four-way (2 × 2 × 2 × 16) repeated measures analysis-of-variance (ANOVA) to evaluate the effects of age group (young vs. old), gender (male vs. female), ear (left vs. right), and frequency (258 to 5040 Hz) on

  10. Blast-related Ear Injuries among U.S. Military Personnel

    DTIC Science & Technology

    2013-08-01

    ment outcomes. The exclusion of servicemembers with history of hearing loss and/or tinnitus before injury was a strength of this study, which allowed...and explore hearing loss and tinnitus outcomes within one year after injury. The Expeditionary Medical Encounter Database was used to identify... tinnitus . The prevalence of ear injuries was 30.7% (1,223 of 3,981). The most common ear injury diagnoses were “inner or middle ear injury involving

  11. Teasing in younger and older children with microtia before and after ear reconstruction.

    PubMed

    Johns, Alexis L; Lewin, Sheryl L; Im, Daniel D

    2017-06-01

    This study prospectively measured teasing and emotional adjustment before and after ear reconstruction in younger and older children with microtia. Participants with isolated microtia (n = 28) were divided into two groups by age at surgery, with a younger group aged 3-5 years (n = 13) with a mean age of 4.0 (0.71) years at the time of surgery and an older group aged 6-10 years old (n = 15) with a mean age of 7.87 (1.30) years. Children and their parents were interviewed preoperatively and a year after surgery about teasing and emotions about their ear(s). Teasing began between the ages of 2.4-4.8 years. A third of the younger group and all of the older group reported preoperative teasing. Before surgery, the older group reported higher rates of negative emotions about their ear(s) and teasing was correlated for all ages with feeling sad, worried, and mad about their ear(s). After surgery, teasing and negative emotions significantly decreased with increased happiness about their ear(s). Postoperative teasing was correlated with trying to hide their ear(s). There were significant interactions from before to after surgery based on surgery age for frequency of teasing, sadness, and feeling mad, with the older group showing relatively greater change postoperatively. Teasing and negative emotions about their ear(s) decreased for all ages after surgery, with a potential protective factor seen in younger surgery age.

  12. Lumped parametric model of the human ear for sound transmission.

    PubMed

    Feng, Bin; Gan, Rong Z

    2004-09-01

    A lumped parametric model of the human auditoria peripherals consisting of six masses suspended with six springs and ten dashpots was proposed. This model will provide the quantitative basis for the construction of a physical model of the human middle ear. The lumped model parameters were first identified using published anatomical data, and then determined through a parameter optimization process. The transfer function of the middle ear obtained from human temporal bone experiments with laser Doppler interferometers was used for creating the target function during the optimization process. It was found that, among 14 spring and dashpot parameters, there were five parameters which had pronounced effects on the dynamic behaviors of the model. The detailed discussion on the sensitivity of those parameters was provided with appropriate applications for sound transmission in the ear. We expect that the methods for characterizing the lumped model of the human ear and the model parameters will be useful for theoretical modeling of the ear function and construction of the ear physical model.

  13. Current Status and Prospects of Gene Therapy for the Inner Ear

    PubMed Central

    Huang, Aji

    2011-01-01

    Abstract Inner ear diseases are common and often result in hearing disability. Sensorineural hearing loss is the main cause of hearing disability. So far, no effective treatment is available although some patients may benefit from a hearing aid equipped with a hearing amplifier or from cochlear implantation. Inner ear gene therapy has become an emerging field of study for the treatment of hearing disability. Numerous new discoveries and tremendous advances have been made in inner ear gene therapy including gene vectors, routes of administration, and therapeutic genes and targets. Gene therapy may become a treatment option for inner ear diseases in the near future. In this review, we summarize the current state of inner ear gene therapy including gene vectors, delivery routes, and therapeutic genes and targets by examining and analyzing publications on inner ear gene therapy from the literature and patent documents, and identify promising patents, novel techniques, and vital research projects. We also discuss the progress and prospects of inner ear gene therapy, the advances and shortcomings, with possible solutions in this field of research. PMID:21338273

  14. Verrucous carcinoma of the middle ear.

    PubMed

    Woodson, G E; Jurco, S; Alford, B R; McGavran, M H

    1981-01-01

    A case of a highly destructive, cytologically nondysplastic squamous epithelial lesion of the middle ear is presented. The cranial nerve involvement and bone destruction are more extensive than has been seen in cholesteatoma. Cultures are negative for Pseudomonas, and the patient does not have the reported diathesis for malignant otitis externa. The gross and microscopic features are those of verrucous carcinoma. To our knowledge, the middle ear has not been previously reported as a site of involvement by verrucous carcinoma.

  15. Correlation between the characteristics of resonance and aging of the external ear.

    PubMed

    Silva, Aline Papin Roedas da; Blasca, Wanderléia Quinhoneiro; Lauris, José Roberto Pereira; Oliveira, Jerusa Roberta Massola de

    2014-01-01

    Aging causes changes in the external ear as a collapse of the external auditory canal and tympanic membrane senile. Knowing them is appropriate for the diagnosis of hearing loss and selection of hearing aids. For this reason, the study aimed to verify the influence of the anatomical changes of the external ear resonance in the auditory canal in the elderly. The sample consisted of objective measures of the external ear of elderly with collapse (group A), senile tympanic membrane (group B) and without changing the external auditory canal or tympanic membrane (group C) and adults without changing the external ear (group D). In the retrospective/clinical study were performed comparisons of measures of individuals with and without alteration of the external ear through the gain and response external ear resonant frequency and the primary peak to the right ear. In groups A, B and C was no statistically significant difference between Real Ear Unaided Response (REUR) and Real Ear Unaided Gain (REUG), but not for the peak frequency. For groups A and B were shown significant differences in REUR and REUG. Between the C and D groups were significant statistics to the REUR and REUG, but not for the frequency of the primary peak. Changes influence the external ear resonance, decreasing its amplitude. However, the frequency of the primary peak is not affected.

  16. Ensemble training to improve recognition using 2D ear

    NASA Astrophysics Data System (ADS)

    Middendorff, Christopher; Bowyer, Kevin W.

    2009-05-01

    The ear has gained popularity as a biometric feature due to the robustness of the shape over time and across emotional expression. Popular methods of ear biometrics analyze the ear as a whole, leaving these methods vulnerable to error due to occlusion. Many researchers explore ear recognition using an ensemble, but none present a method for designing the individual parts that comprise the ensemble. In this work, we introduce a method of modifying the ensemble shapes to improve performance. We determine how different properties of an ensemble training system can affect overall performance. We show that ensembles built from small parts will outperform ensembles built with larger parts, and that incorporating a large number of parts improves the performance of the ensemble.

  17. Multi-resolution analysis for ear recognition using wavelet features

    NASA Astrophysics Data System (ADS)

    Shoaib, M.; Basit, A.; Faye, I.

    2016-11-01

    Security is very important and in order to avoid any physical contact, identification of human when they are moving is necessary. Ear biometric is one of the methods by which a person can be identified using surveillance cameras. Various techniques have been proposed to increase the ear based recognition systems. In this work, a feature extraction method for human ear recognition based on wavelet transforms is proposed. The proposed features are approximation coefficients and specific details of level two after applying various types of wavelet transforms. Different wavelet transforms are applied to find the suitable wavelet. Minimum Euclidean distance is used as a matching criterion. Results achieved by the proposed method are promising and can be used in real time ear recognition system.

  18. The prominent antihelix and helix--the myth of the 'overcorrected' ear in otoplasty.

    PubMed

    Shokrollahi, Kayvan; Manning, Steven; Sadri, Amir; Molajo, Adeyinka; Lineaweaver, William

    2015-06-01

    Classic teaching of ear anatomy in the context of otoplasty states that if the antihelical fold is more prominent than the helical fold after surgery then the ear is "overcorrected." We set out to explore the role of the antihelix in normal ear anatomy, its relevance to aesthetic perceptions of the ear, and a snapshot of its incidence in nonoperated ears. To readily identify junior staff in our department, their color photographs, names, and contact details are posted on every ward. Using digital methods, we cropped the left ear out of the source images, making them unidentifiable. Clinical and nonclinical staff in our unit were asked to choose their favorite and their least favorite ears based on their aesthetic appeal. Responses were tabulated and the 2 most popular ears were compared. The preferred ear did not conform to the traditional dogma because it had a prominent antihelix and was statistically significant when compared to other choices. We also noted that a prominent antihelix is common among the general population and among colleagues within the department, and hence "normal." Also interesting was that the helix of the ear chosen as the most aesthetic was also the ear where the helix was almost touching the side of the head. We found that when judging the aesthetic nature of the "virgin" ear, antihelical fold prominence did not appear to be a negative attribute. Indeed, we noted that a prominent antihelix was a common attribute, and we conclude that this was a normal variant without undue negative aesthetic stigma. A surgically corrected ear should not necessarily be regarded as a poor outcome simply on the basis of antihelical prominence. Furthermore, we postulate that patients who have a prominent antihelix might be part of a spectrum of individuals who might have had the subtype of prominent ears featuring a deep conchal bowl. Finally, although not tested directly, it appears that we do not have an idea of our own ear shape, as none of the

  19. Tomographic imaging of subducted lithosphere below northwest Pacific island arcs

    USGS Publications Warehouse

    Van Der Hilst, R.; Engdahl, R.; Spakman, W.; Nolet, G.

    1991-01-01

    The seismic tomography problem does not have a unique solution, and published tomographic images have been equivocal with regard to the deep structure of subducting slabs. An improved tomographic method, using a more realistic background Earth model and surf ace-reflected as well as direct seismic phases, shows that slabs beneath the Japan and Izu Bonin island arcs are deflected at the boundary between upper and lower mantle, whereas those beneath the northern Kuril and Mariana arcs sink into the lower mantle.

  20. 21 CFR 874.4420 - Ear, nose, and throat manual surgical instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... device includes the esophageal dilator; tracheal bistour (a long, narrow surgical knife); tracheal dilator; tracheal hook; laryngeal injection set; laryngeal knife; laryngeal saw; laryngeal trocar...; wire ear loop; microrule; mirror; mobilizer; ear, nose, and throat punch; ear, nose and throat knife...

  1. Naturopathic treatment for ear pain in children.

    PubMed

    Sarrell, E Michael; Cohen, Herman Avner; Kahan, Ernesto

    2003-05-01

    Otitis media is 1 of the most frequent diseases of early infancy and childhood and 1 of the most common reasons for children to visit a physician. In the past 2 decades, there has been a substantial increase in the diagnosis of otitis media worldwide. In the United States, 93% of all children have had at least 1 episode of acute otitis media (AOM) by 7 years of age. Otalgia is the hallmark of AOM. Most affected children either complain of earache or manifest behavior that the parents interpret as indicating ear pain. Treatment of the ear pain early in the course of AOM decreases both parental anxiety and the child's discomfort and accelerates the healing process. The objective of this study was to determine the efficacy and tolerability of naturopathic versus traditional treatment for the management of otalgia commonly associated with AOM in children. The study was designed as a double-blind trial in an outpatient community clinic. A total of 171 children who were aged 5 to 18 years and had otalgia and clinical findings associated with middle-ear infection were studied. The children were randomly assigned to receive treatment with Naturopathic Herbal Extract Ear Drops (NHED) or anesthetic ear drops, with or without amoxicillin. On enrollment, the children were assigned by computer-numbered randomization to receive NHED (contents: allium sativum, verbascum thapsus, calendula flores, hypericum perfoliatum, lavender, and vitamin E in olive oil) 5 drops 3 times daily, alone (group A) or together with a topical anesthetic (amethocaine and phenazone in glycerin) 5 drops 3 times daily (group B), or oral amoxicillin 80 mg/kg/d (maximum 500 mg/dose) divided into 3 doses with either NHED 5 drops 3 times daily (group C) or topical anesthetic 5 drops 3 times daily (group D). A double-blind design was used, and all ear drops were placed in identical bottles. Treatment was initiated by the nurse in all cases. A single physician (M.S.) evaluated and treated all of the patients

  2. Thumb carpometacarpal joint resurfacing with autologous ear cartilage.

    PubMed

    Nickell, William B

    2014-05-01

    A study was designed to ascertain the long-term effectiveness of using autologous full-thickness ear cartilage to resurface the arthritic face of the trapezium, leaving the body of the trapezium intact. The value of injection of the involved carpometacarpal (CMC) joint with local anesthetic in predicting improvement from the surgery was also studied. An operation was used to enter the CMC joint of the thumb between the thenar muscles and the abductor tendon. The articular surface of the trapezium was resected and resurfaced with full-thickness ear cartilage from the patient's ear. Patients were selected based on constant, unremitting pain. All patients also had x-ray evidence of severe arthritis at the CMC joint of the thumb. Both thumbs were evaluated for pain, range of motion, key and palmar pinch, and grip strength before the surgery and followed up for a minimum of 30 months to be included in the study. Fifty-nine patients had ear cartilage arthroplasty from 1997 to 2007 by the same surgeon with a total of 67 operations (8 patients, all women, had both thumbs operated). Forty-nine of these patients, 4 men and 45 women (53 hands), were available for follow-up and constitute the study group. Eight procedures were done on the left hand, and 45, on the right. There were no ear complications and no cartilage extrusions. All patients had improved range of motion and greatly decreased pain. Strength was equaled or exceeded the unoperated thumb. Preoperative joint injection was a good predictor of postoperative pain relief. All patients were pleased with the result and said that they would have the surgery again. Thumb CMC joint arthroplasty with autologous ear cartilage and preservation of the body of the trapezium is an effective alternative to existing procedures.There is no morbidity to the ear, and predictable long-term improvement in thumb pain and strength can be obtained. Injection of the CMC joint before surgery with local anesthetic is a reliable predictor of

  3. Retroauricular skin: a flaps bank for ear reconstruction.

    PubMed

    Cordova, A; D'Arpa, S; Pirrello, R; Giambona, C; Moschella, F

    2008-01-01

    The retroauricular skin has always been given much attention by the reconstructive surgeon for ear and face reconstruction because it is richly vascularised, as many anatomical investigations show, it is hidden behind the ear, its skin is very similar to that of ear and face. All these reasons make it an ideal donor site for ear reconstruction. The authors propose their own algorithm for reconstruction of every kind of anterior defects of the auricle with different Retroauricular Island Flaps (RIFs) based on the location and size of the defect developed over a 16 years single institution's experience with a series of 216 consecutive cases. 216 patients have undergone ear reconstruction with RIFs from 1999 to 2006. In 52 a Superior Pedicle RIF (SP-RIF) was used for defects of the upper half of the auricle. In 68 cases a Perforator RIF (P-RIF) was used for conchal reconstruction. In 96 cases an Inferior Pedicle RIF (IP-RIF) was used for reconstruction of nonmarginal and superficial marginal defects of the auricle. No flap failure was recorded. Excellent morphological reconstruction was obtained with these flaps with no sequealae at the donor site in terms of form and function. Only in the case of P-RIFs the sulcus becomes flat in its central part, but this has never affected the possibility of wearing spectacles. The SP-RIFs may sometimes show some signs of venous stasis that invariably resolve in the first two postoperative days. The retroauricular skin may be considered a flaps bank for ear reconstruction. It offers in fact a great variety of island flaps that are suitable for every kind of loss of substance of the ear, have a safe vascularisation, skin of similar colour and texture, are easy to harvest under local anaesthesia on an outpatient basis and cause no relevant morbidity at the donor site. Location and size of the defects lead the choice between the different types of RIFs.

  4. Role of skeletal muscle in ear development.

    PubMed

    Rot, Irena; Baguma-Nibasheka, Mark; Costain, Willard J; Hong, Paul; Tafra, Robert; Mardesic-Brakus, Snjezana; Mrduljas-Djujic, Natasa; Saraga-Babic, Mirna; Kablar, Boris

    2017-10-01

    The current paper is a continuation of our work described in Rot and Kablar, 2010. Here, we show lists of 10 up- and 87 down-regulated genes obtained by a cDNA microarray analysis that compared developing Myf5-/-:Myod-/- (and Mrf4-/-) petrous part of the temporal bone, containing middle and inner ear, to the control, at embryonic day 18.5. Myf5-/-:Myod-/- fetuses entirely lack skeletal myoblasts and muscles. They are unable to move their head, which interferes with the perception of angular acceleration. Previously, we showed that the inner ear areas most affected in Myf5-/-:Myod-/- fetuses were the vestibular cristae ampullaris, sensitive to angular acceleration. Our finding that the type I hair cells were absent in the mutants' cristae was further used here to identify a profile of genes specific to the lacking cell type. Microarrays followed by a detailed consultation of web-accessible mouse databases allowed us to identify 6 candidate genes with a possible role in the development of the inner ear sensory organs: Actc1, Pgam2, Ldb3, Eno3, Hspb7 and Smpx. Additionally, we searched for human homologues of the candidate genes since a number of syndromes in humans have associated inner ear abnormalities. Mutations in one of our candidate genes, Smpx, have been reported as the cause of X-linked deafness in humans. Our current study suggests an epigenetic role that mechanical, and potentially other, stimuli originating from muscle, play in organogenesis, and offers an approach to finding novel genes responsible for altered inner ear phenotypes.

  5. Sound pressure gain produced by the human middle ear.

    PubMed

    Kurokawa, H; Goode, R L

    1995-10-01

    The acoustic function of the middle ear is to match sound passing from the low impedance of air to the high impedance of cochlear fluid. Little information is available on the actual middle ear pressure gain in human beings. This article describes experiments on middle ear pressure gain in six fresh human temporal bones. Stapes footplate displacement and phase were measured with a laser Doppler vibrometer before and after removal of the tympanic membrane, malleus, and incus. Acoustic insulation of the round window with clay was performed. Umbo displacement was also measured before tympanic membrane removal to assess baseline tympanic membrane function. The middle ear has its major gain in the lower frequencies, with a peak near 0.9 kHz. The mean gain was 23.0 dB below 1.0 kHz, the resonant frequency of the middle ear; the mean peak gain was 26.6 dB. Above 1.0 kHz, the second pressure gain decreased at a rate of -8.6 dB/octave, with a mean gain of 6.5 dB at 4.0 kHz. Only a small amount of gain was present above 7.0 kHz. Significant individual differences in pressure gain were found between ears that appeared related to variations in tympanic membrane function and not to variations in cochlear impedance.

  6. Contralateral ear occlusion for improving the reliability of otoacoustic emission screening tests.

    PubMed

    Papsin, Emily; Harrison, Adrienne L; Carraro, Mattia; Harrison, Robert V

    2014-01-01

    Newborn hearing screening is an established healthcare standard in many countries and testing is feasible using otoacoustic emission (OAE) recording. It is well documented that OAEs can be suppressed by acoustic stimulation of the ear contralateral to the test ear. In clinical otoacoustic emission testing carried out in a sound attenuating booth, ambient noise levels are low such that the efferent system is not activated. However in newborn hearing screening, OAEs are often recorded in hospital or clinic environments, where ambient noise levels can be 60-70 dB SPL. Thus, results in the test ear can be influenced by ambient noise stimulating the opposite ear. Surprisingly, in hearing screening protocols there are no recommendations for avoiding contralateral suppression, that is, protecting the opposite ear from noise by blocking the ear canal. In the present study we have compared transient evoked and distortion product OAEs measured with and without contralateral ear plugging, in environmental settings with ambient noise levels <25 dB SPL, 45 dB SPL, and 55 dB SPL. We found out that without contralateral ear occlusion, ambient noise levels above 55 dB SPL can significantly attenuate OAE signals. We strongly suggest contralateral ear occlusion in OAE based hearing screening in noisy environments.

  7. A short-wave infrared otoscope for middle ear disease diagnostics (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Carr, Jessica A.; Valdez, Tulio; Bruns, Oliver; Bawendi, Moungi

    2016-02-01

    Otitis media, a range of inflammatory conditions of the middle ear, is the second most common illness diagnosed in children. However, the diagnosis can be challenging, particularly in pediatric patients. Otitis media is commonly over-diagnosed and over-treated and has been identified as one of the primary factors in increased antibiotic resistance. We describe the development of a short-wave infrared (SWIR) otoscope for objective middle ear effusion diagnosis. The SWIR otoscope can unambiguously detect the presence of middle ear fluid based on its strong light absorption in the SWIR. This absorption causes a stark, visual contrast between the presence and absence of fluid behind the tympanic membrane. Additionally, when there is no middle ear fluid, the deeper tissue penetration of SWIR light allows the SWIR otoscope to better visualize middle ear anatomy through the tympanic membrane than is possible with visible light. We demonstrate that in healthy, adult human ears, SWIR otoscopy can image a range of middle ear anatomy, including landmarks of the entire ossicular chain, the promontory, the round window niche, and the chorda tympani. We suggest that SWIR otoscopy can provide valuable diagnostic information complementary to that provided by visible pneumotoscopy in the diagnosis of middle ear effusions, otitis media, and other maladies of the middle ear.

  8. Desmoplastic small round cell tumor of the middle ear: A case report.

    PubMed

    Xu, Jing; Yao, Mengwei; Yang, Xinxin; Liu, Tao; Wang, Shaohua; Ma, Dengdian; Li, Xiaoyu

    2018-04-01

    Desmoplastic small round cell tumor (DSRCT) is a rare, aggressive and malignant tumor. This report describes a case involving DSRCT of the middle ear which no case has been reported in the literature till date. A 59-year-old Chinese man with a 40-year history of repeated suppuration of his right ear and 1-year history of drooping of the angle of mouth. The CT of the middle ear and brain scan and enhanced MRI showed space occupying lesion in the right middle ear. Desmoplastic small round cell tumor of the middle ear. After relevant examinations, radical mastoidectomy and subtotal temporal bone resection were performed on the right ear under general anesthesia. The patient underwent postoperative adjuvant chemoradiation therapy. The patient was counterchecked regularly,there was norecurrence of DSRCT of the middle ear. Four years after surgery, the CT and MRI of the middle ear mastoid showed right middle ear soft tissue shadow,but postoperative pathological results showed proliferative fibrous and vascular tissues with chronic inflammatory cell infiltration and necrosis. DSRCT is a relatively aggressive, malignant mesenchymal tumor, with a very poor prognosis.The diagnosis of DSRCT relies on immunohistological data. Early diagnosis, radical surgery, chemotherapy, and radiotherapy are considered a reasonable way to prolong survival.

  9. How minute sooglossid frogs hear without a middle ear.

    PubMed

    Boistel, Renaud; Aubin, Thierry; Cloetens, Peter; Peyrin, Françoise; Scotti, Thierry; Herzog, Philippe; Gerlach, Justin; Pollet, Nicolas; Aubry, Jean-François

    2013-09-17

    Acoustic communication is widespread in animals. According to the sensory drive hypothesis [Endler JA (1993) Philos Trans R Soc Lond B Biol Sci 340(1292):215-225], communication signals and perceptual systems have coevolved. A clear illustration of this is the evolution of the tetrapod middle ear, adapted to life on land. Here we report the discovery of a bone conduction-mediated stimulation of the ear by wave propagation in Sechellophryne gardineri, one of the world's smallest terrestrial tetrapods, which lacks a middle ear yet produces acoustic signals. Based on X-ray synchrotron holotomography, we measured the biomechanical properties of the otic tissues and modeled the acoustic propagation. Our models show how bone conduction enhanced by the resonating role of the mouth allows these seemingly deaf frogs to communicate effectively without a middle ear.

  10. Altered Expression of Middle and Inner Ear Cytokines in Mouse Otitis Media

    PubMed Central

    MacArthur, Carol J.; Pillers, De-Ann M.; Pang, Jiaqing; Kempton, J. Beth; Trune, Dennis R.

    2010-01-01

    Objectives/Hypothesis The inner ear is at risk for sensorineural hearing loss in both acute and chronic otitis media (OM), but the underlying mechanisms underlying sensorineural hearing loss are unknown. Previous gene expression array studies showed cytokine genes might be upregulated in the cochleas of mice with acute and chronic otitis media. This implies that the inner ear could manifest a direct inflammatory response to OM that may cause sensorineural damage. Therefore, to better understand inner ear cytokine gene expression during OM, quantitative RT-PCR and immunohistochemistry were performed on mouse models to evaluate middle and inner ear inflammatory and remodeling cytokines. Study Design Basic science experiment. Methods An acute OM model was created in Balb/c mice by a transtympanic injection of S. pneumoniae in one ear; the other ear used as a control. C3H/HeJ mice were screened for unilateral chronic OM with the non-infected ear serving as control. Results Both acute and chronic OM caused both the middle ear and inner tissues in these two mouse models to over express numerous cytokine genes related to tissue remodeling (TNFα, FGF, BMP) and angiogenesis (VEGF), as well as inflammatory cell proliferation (IL-1α,β, IL-2, IL-6). Immunohistochemistry confirmed that both the middle ear and inner ear tissues expressed these cytokines. Conclusion Cochlear tissues are capable of expressing cytokine mRNA that contributes to the inflammation and remodeling that occur in association with middle ear disease. This provides a potential molecular basis for the transient and permanent sensorineural hearing loss often reported with acute and chronic OM. Level of Evidence N/A PMID:21271590

  11. Continental Deformation in Madagascar from GNSS Observations

    NASA Astrophysics Data System (ADS)

    Stamps, D. S.; Rajaonarison, T.; Rambolamanana, G.; Herimitsinjo, N.; Carrillo, R.; Jesmok, G.

    2015-12-01

    D.S. Stamps, T. Rajaonarison, G. Rambolamanana Madagascar is the easternmost continental segment of the East African Rift System (EARS). Plate reconstructions assume the continental island behaves as a rigid block, but studies of geologically recent kinematics suggest Madagascar undergoes extension related to the broader EARS. In this work we test for rigidity of Madagascar in two steps. First, we quantify surface motions using a novel dataset of episodic and continuous GNSS observations that span Madagascar from north to south. We established a countrywide network of precision benchmarks fixed in bedrock and with open skyview in 2010 that we measured for 48-72 hours with dual frequency receivers. The benchmarks were remeasured in 2012 and 2014. We processed the episodic GNSS data with ABPO, the only continuous GNSS station in Madagascar with >2.5 years of data, for millimeter precision positions and velocities at 7 locations using GAMIT-GLOBK. Our velocity field shows 2 mm/yr of differential motion between southern and northern Madagascar. Second, we test a suite of kinematic predictions from previous studies and find residual velocities are greater than 95% uncertainties. We also calculate angular velocity vectors assuming Madagascar moves with the Lwandle plate or the Somalian plate. Our new velocity field in Madagascar is inconsistent with all models that assume plate rigidity at the 95% uncertainty level; this result indicates the continental island undergoes statistically significant internal deformation.

  12. Vitamin D receptor deficiency impairs inner ear development in zebrafish.

    PubMed

    Kwon, Hye-Joo

    2016-09-16

    The biological actions of vitamin D are largely mediated through binding to the vitamin D receptor (VDR), a member of the nuclear hormone receptor family, which regulates gene expression in a wide variety of tissues and cells. Mutations in VDR gene have been implicated in ear disorders (hearing loss and balance disorder) but the mechanisms are not well established. In this study, to investigate the role of VDR in inner ear development, morpholino-mediated gene knockdown approaches were used in zebrafish model system. Two paralogs for VDR, vdra and vdrb, have been identified in zebrafish. Knockdown of vdra had no effect on ear development, whereas knockdown of vdrb displayed morphological ear defects including smaller otic vesicles with malformed semicircular canals and abnormal otoliths. Loss-of-vdrb resulted in down-regulation of pre-otic markers, pax8 and pax2a, indicating impairment of otic induction. Furthermore, zebrafish embryos lacking vdrb produced fewer sensory hair cells in the ears and showed disruption of balance and motor coordination. These data reveal that VDR signaling plays an important role in ear development. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. KGFR as a possible therapeutic target in middle ear cholesteatoma.

    PubMed

    Yamamoto-Fukuda, Tomomi; Akiyama, Naotaro; Shibata, Yasuaki; Takahashi, Haruo; Ikeda, Tohru; Kohno, Michiaki; Koji, Takehiko

    2014-11-01

    We demonstrated that repression of keratinocyte growth factor (KGF) receptor (KGFR) could be a potentially useful strategy in the conservative treatment of middle ear cholesteatoma. Recently, the use of a selective inhibitor of the KGFR, SU5402, in an in vitro experiment resulted in the inhibition of the differentiation and proliferation of epithelial cells through KGF secretion by fibroblasts isolated from the cholesteatoma. In this study, we investigated the effects of the KGFR inhibitor during middle ear cholesteatoma formation in vivo. Based on the role of KGF in the development of cholesteatoma, Flag-hKGF cDNA driven by CMV14 promoter was transfected through electroporation into the external auditory canal of rats five times on every fourth day. Ears transfected with empty vector were used as controls. KGFR selective inhibitor (SU5402) or MEK inhibitor (PD0325901) was administered in the right ear of five rats after vector transfection. In the control, 2% DMSO in PBS was administered in the other ears after vector transfection. The use of a selective KGFR inhibitor, SU5402, completely prevented middle ear cholesteatoma formation in the rats.

  14. Inner ear test battery in guinea pig models - a review.

    PubMed

    Young, Yi-Ho

    2018-06-01

    This study reviewed the development of the inner ear test battery comprising auditory brainstem response (ABR), and caloric, ocular vestibular-evoked myogenic potential (oVEMP), and cervical vestibular-evoked myogenic potential (cVEMP) tests in guinea pig models at our laboratory over the last 20 years. Detailed description of the methodology for testing the small animals is also included. Inner ear disorders, i.e. ototoxicity, noise exposure, or perilymph fistula were established in guinea pig models first. One to four weeks after operation, each animal underwent ABR, oVEMP, cVEMP, and caloric tests. Then, animals were sacrificed for morphological study in the temporal bones. Inner ear endorgans can be comprehensively evaluated in guinea pig models via an inner ear test battery, which provides thorough information on the cochlea, saccule, utricle, and semicircular canal function of guinea pigs. Coupled with morphological study in the temporal bones of the animals may help elucidate the mechanism of inner ear disorders in humans. The inner ear test battery in guinea pig models may encourage young researchers to perform basic study in animals and stimulate the progress of experimental otology which is in evolution.

  15. Bilateral external ear canal osteomas - discussion on a clinical case.

    PubMed

    Gheorghe, D C; Stanciu, A E; Ulici, A; Zamfir-Chiru-Anton, A

    2016-01-01

    Osteomas of the external ear are uncommon benign tumors that need to be differentiated from the external ear canal exostoses, bony proliferations that are linked mainly to cold-water exposure. Clinical manifestations vary from no symptoms to recurrent local infections and external ear cholesteatoma. Objective: presenting a rare case that we did not find described in the published literature. A patient with multiple long-term asymptomatic osteomas of both external ear canals presented to our department. Material: Data recorded from the patient's medical record was reviewed and analyzed. Surgery was performed and histology confirmed the presumptive diagnosis. Results: There was a discrepancy between the local severity of the disease, with a complete obstruction of his ear canals, and the long-term disease-free status of the patient. Conclusion: We hypothesized about the etiology of these multiple bilateral osteomas of the EAC, in light of the clinical and surgical findings.

  16. Direct cost comparison of totally endoscopic versus open ear surgery.

    PubMed

    Patel, N; Mohammadi, A; Jufas, N

    2018-02-01

    Totally endoscopic ear surgery is a relatively new method for managing chronic ear disease. This study aimed to test the null hypothesis that open and endoscopic approaches have similar direct costs for the management of attic cholesteatoma, from an Australian private hospital setting. A retrospective direct cost comparison of totally endoscopic ear surgery and traditional canal wall up mastoidectomy for the management of attic cholesteatoma in a private tertiary setting was undertaken. Indirect and future costs were excluded. A direct cost comparison of anaesthetic setup and resources, operative setup and resources, and surgical time was performed between the two techniques. Totally endoscopic ear surgery has a mean direct cost reduction of AUD$2978.89 per operation from the hospital perspective, when compared to canal wall up mastoidectomy. Totally endoscopic ear surgery is more cost-effective, from an Australian private hospital perspective, than canal wall up mastoidectomy for attic cholesteatoma.

  17. Selective forces on origin, adaptation and reduction of tympanal ears in insects.

    PubMed

    Strauß, Johannes; Stumpner, Andreas

    2015-01-01

    Insect ears evolved many times independently. As a consequence, a striking diversity exists in the location, construction and behavioural implementation of ears. In this review, we first summarise what is known about the evolutionary origin of ears and the presumed precursor organs in the various insect groups. Thereafter, we focus on selective forces for making and keeping an ear: we discuss detecting and localising predators and conspecifics, including establishing new "private" channels for intraspecific communication. More advanced aspects involve judging the distance of conspecifics, or assessing individual quality from songs which makes auditory processing a means for exerting sexual selection on mating partners. We try to identify negative selective forces, mainly in the context of energy expenditure for developing and keeping an ear, but also in conjunction with acoustic communication, which incorporates risks like eavesdropping by predators and parasitoids. We then discuss balancing pressures, which might oppose optimising an ear for a specific task (when it serves different functions, for example). Subsequently, we describe various scenarios that might have led to a reduction or complete loss of ears in evolution. Finally, we describe cases of sex differences in ears and potential reasons for their appearance.

  18. Surgical and Technical Modalities for Hearing Restoration in Ear Malformations.

    PubMed

    Dazert, Stefan; Thomas, Jan Peter; Volkenstein, Stefan

    2015-12-01

    Malformations of the external and middle ear often go along with an aesthetic and functional handicap. Independent of additional aesthetic procedures, a successful functional hearing restoration leads to a tremendous gain in quality of life for affected patients. The introduction of implantable hearing systems (bone conduction and middle ear devices) offers new therapeutic options in this field. We focus on functional rehabilitation of patients with malformations, either by surgical reconstruction or the use of different implantable hearing devices, depending on the disease itself and the severity of malformation as well as hearing impairment. Patients with an open ear canal and minor malformations are good candidates for surgical hearing restoration of middle ear structures with passive titanium or autologous implants. In cases with complete fibrous or bony atresia of the ear canal, the most promising functional outcome and gain in quality of life can be expected with an active middle ear implant or a bone conduction device combined with a surgical aesthetic rehabilitation in a single or multi-step procedure. Although the surgical procedure for bone conduction devices is straightforward and safe, more sophisticated operations for active middle ear implants (e.g., Vibrant Soundbridge, MED-EL, Innsbruck, Austria) provide an improved speech discrimination in noise and the ability of sound localization compared with bone conduction devices where the stimulation reaches both cochleae. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. [European Portuguese EARS test battery adaptation].

    PubMed

    Alves, Marisa; Ramos, Daniela; Oliveira, Graça; Alves, Helena; Anderson, Ilona; Magalhães, Isabel; Martins, Jorge H; Simões, Margarida; Ferreira, Raquel; Fonseca, Rita; Andrade, Susana; Silva, Luís; Ribeiro, Carlos; Ferreira, Pedro Lopes

    2014-01-01

    The use of adequate assessment tools in health care is crucial for the management of care. The lack of specific tools in Portugal for assessing the performance of children who use cochlear implants motivated the translation and adaptation of the EARS (Evaluation of Auditory Responses to Speech) test battery into European Portuguese. This test battery is today one of the most commonly used by (re)habilitation teams of deaf children who use cochlear implants worldwide. The goal to be achieved with the validation of EARS was to provide (re)habilitation teams an instrument that enables: (i) monitoring the progress of individual (re)habilitation, (ii) managing a (re)habilitation program according to objective results, comparable between different (re)habilitation teams, (iii) obtaining data that can be compared with the results of international teams, and (iv) improving engagement and motivation of the family and other professionals from local teams. For the test battery translation and adaptation process, the adopted procedures were the following: (i) translation of the English version into European Portuguese by a professional translator, (ii) revision of the translation performed by an expert panel, including doctors, speech-language pathologists and audiologists, (iii) adaptation of the test stimuli by the team's speechlanguage pathologist, and (iv) further review by the expert panel. For each of the tests that belong to the EARS battery, the introduced adaptations and adjustments are presented, combining the characteristics and objectives of the original tests with the linguistic and cultural specificities of the Portuguese population. The difficulties that have been encountered during the translation and adaptation process and the adopted solutions are discussed. Comparisons are made with other versions of the EARS battery. We defend that the translation and the adaptation process followed for the EARS test battery into European Portuguese was correctly conducted

  20. Biocompatibility of Liposome Nanocarriers in the Rat Inner Ear After Intratympanic Administration

    NASA Astrophysics Data System (ADS)

    Zou, Jing; Feng, Hao; Sood, Rohit; Kinnunen, Paavo K. J.; Pyykko, Ilmari

    2017-05-01

    Liposome nanocarriers (LPNs) are potentially the future of inner ear therapy due to their high drug loading capacity and efficient uptake in the inner ear after a minimally invasive intratympanic administration. However, information on the biocompatibility of LPNs in the inner ear is lacking. The aim of the present study is to document the biocompatibility of LPNs in the inner ear after intratympanic delivery. LPNs with or without gadolinium-tetra-azacyclo-dodecane-tetra-acetic acid (Gd-DOTA) were delivered to the rats through transtympanic injection. The distribution of the Gd-DOTA-containing LPNs in the middle and inner ear was tracked in vivo using MRI. The function of the middle and inner ear barriers was evaluated using gadolinium-enhanced MRI. The auditory function was measured using auditory brainstem response (ABR). The potential inflammatory response was investigated by analyzing glycosaminoglycan and hyaluronic acid secretion and CD44 and TLR2 expression in the inner ear. The potential apoptosis was analyzed using terminal transferase (TdT) to label the free 3'OH breaks in the DNA strands of apoptotic cells with TMR-dUTP (TUNEL staining). As a result, LPNs entered the inner ear efficiently after transtympanic injection. The transtympanic injection of LPNs with or without Gd-DOTA neither disrupted the function of the middle and inner ear barriers nor caused hearing impairment in rats. The critical inflammatory biological markers in the inner ear, including glycosaminoglycan and hyaluronic acid secretion and CD44 and TLR2 expression, were not influenced by the administration of LPNs. There was no significant cell death associated with the administration of LPNs. The transtympanic injection of LPNs is safe for the inner ear, and LPNs may be applied as a drug delivery matrix in the clinical therapy of sensorineural hearing loss.

  1. The burned ear; possibilities and challenges in framework reconstruction and coverage.

    PubMed

    Bos, E J; Doerga, P; Breugem, C C; van Zuijlen, P P

    2016-11-01

    Ear reconstruction remains a challenging procedure, especially in burn victims. The ear is particularly vulnerable to thermal injury because of its location and the thin integument. The thermal injury could subsequently include skin and the deeper located auricular cartilage framework. This type of injury could have long lasting mutilating effect not only because the ear's morphology is mainly related to this framework but also because it will not recover or regenerate once injured. Grafts of costal cartilage or synthetic materials might replace missing cartilage. However, the poor quality of the adjacent skin and subcutaneous tissues makes the reconstruction of a burned ear an even more daunting procedure than congenital or many oncologic indications. As such, regeneration of the skin will be the next step in reconstruction of the burned ear. There is still much development and research to be done, but encouraging results have been shown in tissue engineering of skin and cartilage. Furthermore, 3D (bio)printing of cartilage to facilitate reproduction of the ear's complex shape certainly has potential and might find an interesting role in ear reconstruction. In this review, different clinical challenges and options for ear reconstruction in burn patients are described. Subsequently, although still far from large scale clinical application, state of the art developments in the field of tissue engineering and 3D (bio)printing are also discussed. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  2. Recovery time for inflamed middle ear mucosa in chronic otitis media.

    PubMed

    Pakır, Onur; Dinç, Aykut Erdem; Damar, Murat; Akyıldız, İlker; Eliçora, Sultan Şevik; Erdem, Duygu

    2016-01-01

    The present study shows that 2-3 weeks after medical treatment the status of middle ear mucosa in draining ears is similar to that of dry ears for at least 3 months. To measure the time required for an inflamed middle ear mucosa to return into optimal state after appropriate medical treatment in chronic suppurative otitis media (CSOM). To assess optimal timing for elective surgical treatment of draining ears in uncomplicated CSOM. In this prospective study, the Eustachian tube (ET) mucociliary clearance time (MCT) was used as the method to demonstrate the status of middle ear mucosa. In group 1 (28 patients) ET-MCT was measured in ears that were free of drainage for at least 3 months. In Group 2 (21 patients), ET-MCT was measured in draining ears, who responded to 10-14 days medical treatment, at presentation, after 10 days and 1 month. The ET-MCT was 8.63 ± 1.32 min in group 1 and 28.96 ± 8.19 min in group 2 at presentation; and the difference was statistically significant (p < 0.001). The ET-MCT was 14.76 ± 5.11 min after 10 days and 9.31 ± 2.33 min after 1 month in group 2. The ET-MCT was indifferent between groups 1 and 2 after 1 month (p = 0.235).

  3. Ionizing Radiation and the Ear

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borsanyi, Steven J.

    The effects of ionizing radiation on the ears of 100 patients were studied in the course of treatment of malignant head and neck tumors by teleradiation using Co 60. Early changes consisted of radiation otitis media and a transient vasculitis of the vessels of the inner ear, resulting in hearing loss, tinnitus, and temporary recruitment. While no permanent changes were detected microscopically shortly after the completion of radiation in the cochlea or labyrinth, late changes sometimes occurred in the temporal bone as a result of an obliterating endarteritis. The late changes were separate entities caused primarily by obliterating endarteritis andmore » alterations in the collagen. Radiation affected the hearing of individuals selectively. When hearing threshold shift did occur, the shift was not great. The 4000 cps frequency showed a greater deficit in hearing capacity during the tests, while the area least affected appeared to be in the region of 2000 cps. The shift in speech reception was not significant and it was correlated with the over-all change in response to pure tones. Discrimination did not appear to be affected. Proper shielding of the ear with lead during radiation, when possible, eliminated most complications. (H.R.D.)« less

  4. Does ear endoscopy provide advantages in the outpatient management of open mastoidectomy cavities?

    PubMed

    Freire, Gustavo Subtil Magalhães; Sampaio, Andre Luiz Lopes; Lopes, Rafaela Aquino Fernandes; Nakanishi, Márcio; de Oliveira, Carlos Augusto Costa Pires

    2018-01-01

    To evaluate the use of ear endoscopy in the postoperative management of open mastoidectomy cavities, and to test whether ear endoscopy improves inspection and cleaning compared with ear microscopy. Prospective study. Thirty-two ears were divided into two groups: group 1, examination and cleaning of mastoid cavities under endoscopic visualization after microscopic standard ear cleaning; group 2, examination and cleaning of mastoid cavities under microscopic visualization after endoscope-assisted ear cleaning. We assessed the ability of each method to provide exposure and facilitate cleaning, comparing the benefits of microscopy and endoscopy when used sequentially and vice-versa. Endoscopy provided additional benefits for exposure in 61.1% of cases and cleaning in 66.7%. Microscopy provided no additional benefits in terms of exposure in any case, and provided added benefit for cleaning in only 21.4% of cases. For outpatient postoperative care of open mastoidectomy cavities, ear endoscopy provides greater benefit over ear microscopy than vice-versa. In over half of all cases, endoscopy was able to expose areas not visualized under the microscope. Furthermore, in two-thirds of cases, endoscopy enabled removal of material that could not be cleared under microscopy. Ear endoscopy was superior to microscopy in terms of enabling exposure and cleaning of hard-to-reach sites, due to its wider field of vision. Ear endoscopy is a feasible technique for the postoperative management of open mastoidectomy cavities. Ear endoscopy provided superior advantages in terms of exposure and aural cleaning compared with microscopy.

  5. Sturge-Weber syndrome: ear, nose, and throat issues and neurologic status.

    PubMed

    Irving, Natasha D; Lim, Jae Hyung; Cohen, Bernard; Ferenc, Lisa M; Comi, Anne M

    2010-10-01

    The pathophysiology of Sturge-Weber syndrome is poorly understood, and ear, nose, and throat involvement is possible. These issues can result in frequent illnesses or airway obstruction, affecting patients' neurologic status. Patients with definite brain involvement who reported potential ear, nose, and throat issues on intake questionnaires underwent retrospective reviews of their medical records. We examined the relationships between these issues, secondary surgical interventions, and patients' neurologic status. The most common complaints involved the sinuses and frequent ear infections. Six patients underwent placement of ear tubes, leading to improvements in migraines and stroke-like episodes in one patient, and improved seizure control in four others. Obstructive sleep apnea was confirmed in three patients who underwent sleep studies. Tonsil or adenoid removal occurred in another three patients. Surgery resulted in marked improvements regarding excessive drooling, daytime sleepiness, and breathing problems. These findings suggest that ear, nose, and throat problems occur frequently in patients with Sturge-Weber Syndrome, and when repeated ear infections are associated with uncontrolled seizures, early placement of ear tubes may be beneficial. Furthermore, patients with facial tissue hypertrophy may be at risk for obstructive sleep apnea, and should be appropriately evaluated. Copyright © 2010 Elsevier Inc. All rights reserved.

  6. 21 CFR 874.5220 - Ear, nose, and throat drug administration device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ear, nose, and throat drug administration device. 874.5220 Section 874.5220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5220 Ear, nose...

  7. 21 CFR 874.5220 - Ear, nose, and throat drug administration device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ear, nose, and throat drug administration device. 874.5220 Section 874.5220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5220 Ear, nose...

  8. 21 CFR 874.5220 - Ear, nose, and throat drug administration device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ear, nose, and throat drug administration device. 874.5220 Section 874.5220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5220 Ear, nose...

  9. 21 CFR 874.5220 - Ear, nose, and throat drug administration device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ear, nose, and throat drug administration device. 874.5220 Section 874.5220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5220 Ear, nose...

  10. 21 CFR 874.5220 - Ear, nose, and throat drug administration device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear, nose, and throat drug administration device. 874.5220 Section 874.5220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5220 Ear, nose...

  11. [Transitory evoked otoacoustic emissions and distortion product emissions in disorders of middle ear ventilation].

    PubMed

    Schmuziger, N; Hauser, R; Probst, R

    1996-06-01

    Both the amplitude and power spectra of otoacoustic emissions are affected by the transfer properties of the middle ear. This prospective study examined the influence of eustachian tube dysfunction on transiently evoked otoacoustic emissions (TEOAEs) and distortion-product otoacoustic emissions (DPOAEs). In all, 18 ears were studied that exhibited negative middle ear pressures with or without middle ear fluid. Measurements were performed at the time of diagnosis during the recovery stage, and after the middle ear became normally ventilated. Findings showed that TEOAE and DPOAE levels increased while airbone gaps were reduced by an average of 8 dB after negative middle ear pressures returned from -400 daPa to a normal state. There was a tendency for negative middle ear pressure to affect DPOAEs more in the 1-kHz region than in higher frequencies. By contrast, TEOAEs and airbone gaps were more uniformly affected across the entire frequency range. These results for ears with eustachian tube dysfunction were somewhat different from those results of studies obtained in healthy ears tested during experimental changes in middle ear pressure.

  12. The effect of continuous positive airway pressure on middle ear pressure.

    PubMed

    Lin, Fred Y; Gurgel, Richard K; Popelka, Gerald R; Capasso, Robson

    2012-03-01

    While continuous positive airway pressure (CPAP) is commonly used for obstructive sleep apnea treatment, its effect on middle ear pressure is unknown. The purpose of this study was to measure the effect of CPAP on middle ear pressure and describe the correlation between CPAP levels and middle ear pressures. Retrospective review of normal tympanometry values and a prospective cohort evaluation of subjects' tympanometric values while using CPAP at distinct pressure levels. A total of 3,066 tympanograms were evaluated to determine the normal range of middle ear pressures. Ten subjects with no known history of eustachian tube dysfunction or obstructive sleep apnea had standard tympanometry measurements while wearing a CPAP device. Measurements were taken at baseline and with CPAP air pressures of 0, 5, 10, and 15 cm H(2)O. The percentage of normal control patients with middle ear pressures above 40 daPa was 0.03%. In the study population, prior to a swallowing maneuver to open the eustachian tube, average middle ear pressures were 21.67 daPa, 22.63 daPa, 20.42, daPa, and 21.58 daPa with CPAP pressures of 0, 5, 10, and 15 cm H(2) 0, respectively. After swallowing, average middle ear air pressures were 18.83 daPa, 46.75 daPa, 82.17 daPa, and 129.17 daPa with CPAP pressures of 0, 5, 10, and 15 cm H(2)0, respectively. The postswallow Pearson correlation coefficient correlating CPAP and middle ear pressures was 0.783 (P < 0.001). Middle ear air pressure is directly proportional to CPAP air pressure in subjects with normal eustachian tube function. Middle ear pressure reaches supraphysiologic levels at even minimal CPAP levels. Although further investigation is necessary, there may be otologic implications for patients who are chronically CPAP dependent. These findings may also influence the perioperative practice of otologic and skull base surgeons. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  13. Comparison of nine methods to estimate ear-canal stimulus levels

    PubMed Central

    Souza, Natalie N.; Dhar, Sumitrajit; Neely, Stephen T.; Siegel, Jonathan H.

    2014-01-01

    The reliability of nine measures of the stimulus level in the human ear canal was compared by measuring the sensitivity of behavioral hearing thresholds to changes in the depth of insertion of an otoacoustic emission probe. Four measures were the ear-canal pressure, the eardrum pressure estimated from it and the pressure measured in an ear simulator with and without compensation for insertion depth. The remaining five quantities were derived from the ear-canal pressure and the Thévenin-equivalent source characteristics of the probe: Forward pressure, initial forward pressure, the pressure transmitted into the middle ear, eardrum sound pressure estimated by summing the magnitudes of the forward and reverse pressure (integrated pressure) and absorbed power. Two sets of behavioral thresholds were measured in 26 subjects from 0.125 to 20 kHz, with the probe inserted at relatively deep and shallow positions in the ear canal. The greatest dependence on insertion depth was for transmitted pressure and absorbed power. The measures with the least dependence on insertion depth throughout the frequency range (best performance) included the depth-compensated simulator, eardrum, forward, and integrated pressures. Among these, forward pressure is advantageous because it quantifies stimulus phase. PMID:25324079

  14. How do tympanic-membrane perforations affect human middle-ear sound transmission?

    PubMed

    Voss, S E; Rosowski, J J; Merchant, S N; Peake, W T

    2001-01-01

    Although tympanic-membrane (TM) perforations are common sequelae of middle-ear disease, the hearing losses they cause have not been accurately determined, largely because additional pathological conditions occur in these ears. Our measurements of acoustic transmission before and after making controlled perforations in cadaver ears show that perforations cause frequency-dependent loss that: (1) is largest at low frequencies; (2) increases as perforation size increases; and (3) does not depend on perforation location. The dominant loss mechanism is the reduction in sound-pressure difference across the TM. Measurements of middle-ear air-space sound pressures show that transmission via direct acoustic stimulation of the oval and round windows is generally negligible. A quantitative model predicts the influence of middle-ear air-space volume on loss; with larger volumes, loss is smaller.

  15. Inner ear dysplasia is common in children with Down syndrome (trisomy 21).

    PubMed

    Blaser, Susan; Propst, Evan J; Martin, Daniel; Feigenbaum, Annette; James, Adrian L; Shannon, Patrick; Papsin, Blake C

    2006-12-01

    Middle and external ear anomalies are well recognized in Down syndrome (DS, trisomy 21). Inner ear anomalies are much less frequently described. This study reviews inner ear morphology on imaging to determine the prevalence of cochlear and vestibular anomalies in children with DS. The authors conducted a retrospective review of imaging features of (DS) inner ear structures. Fifty-nine sequential patients with DS with imaging of the inner ear were identified by a radiology report text search program. Quantitative biometric assessment of the inner ear was performed on patients with high-resolution computed tomography or magnetic resonance images of the petrous bone. Petrous imaging was performed for evaluation of inflammatory disease or hearing loss. Spinal imaging, which included petrous views, was performed in most cases to exclude C1 to 2 dislocation, a potential complication of DS. Measurements were compared with normative data. Inner ear dysplasia is much more common in DS than previously reported. Inner ear structures are universally hypoplastic. Vestibular malformations are particularly common and a small bony island of the lateral semicircular canal (<3 mm in diameter) appears highly typical. Additional findings in some patients were persistent lateral semicircular anlage with fusion of the lateral semicircular canal and vestibule into a single cavity, vestibular aqueduct and endolymphatic sac fossa enlargement, cochlear nerve canal hypoplasia, and stenosis or duplication of the internal auditory canal. Stenosis of the external meatus, poor mastoid pneumatization, middle ear and mastoid opacification, and cholesteatoma were common, as expected.

  16. Postganglionic horner syndrome in three patients with coincident middle ear infection.

    PubMed

    Spector, Robert H

    2008-09-01

    Three patients developed a postganglionic Horner syndrome during the course of an ipsilateral uncomplicated middle ear infection. The mechanism may be an effect on the middle ear caroticotympanic sympathetic plexus, for which there is considerable anatomic and physiologic evidence. Why Horner syndrome does not occur more often after middle ear infection is a mystery.

  17. Update on Middle Ear Barotrauma after Hyperbaric Oxygen Therapy—Insights on Pathophysiology

    PubMed Central

    Lima, Marco Antônio Rios; Farage, Luciano; Cury, Maria Cristina Lancia; Bahamad, Fayez

    2014-01-01

    Introduction Middle ear barotrauma is the most common side effect of hyperbaric oxygen therapy. Knowledge and understanding of its pathophysiology are crucial for an accurate diagnosis and proper decision making about treatment and prevention. Objective Describe up-to-date information on pathophysiology of middle ear barotrauma after hyperbaric oxygen therapy considering the physiology of pressure variation of the middle ear. Data Synthesis Middle ear barotrauma occurs especially during the compression phase of hyperbaric oxygen therapy. The hyperoxic environment in hyperbaric oxygen therapy leads to ventilatory dysfunction of the eustachian tube, especially in monoplace chambers, where the patients are pressurized with 100% O2, favoring middle ear barotrauma. Conclusion The eustachian tube, the tympanic cavity, and mastoid work together in a neural controlled feedback system in which various mechanisms concur for middle ear pressure regulation. PMID:25992091

  18. Experiments and improvements of ear recognition based on local texture descriptors

    NASA Astrophysics Data System (ADS)

    Benzaoui, Amir; Adjabi, Insaf; Boukrouche, Abdelhani

    2017-04-01

    The morphology of the human ear presents rich and stable information embedded on the curved 3-D surface and has as a result attracted considerable attention from forensic scientists and engineers as a biometric recognition modality. However, recognizing a person's identity from the morphology of the human ear in unconstrained environments, with insufficient and incomplete training data, strong person-specificity, and high within-range variance, can be very challenging. Following our previous work on ear recognition based on local texture descriptors, we propose to use anatomical and embryological information about the human ear in order to find the autonomous components and the locations where large interindividual variations can be detected. Embryology is particularly relevant to our approach as it provides information on the possible changes that can be observed in the external structure of the ear. We experimented with three publicly available databases, namely: IIT Delhi-1, IIT Delhi-2, and USTB-1, consisting of several ear benchmarks acquired under varying conditions and imaging qualities. The experiments show excellent results, beyond the state of the art.

  19. Ear-Canal Reflectance, Umbo Velocity and Tympanometry in Normal Hearing Adults

    PubMed Central

    Rosowski, John J; Nakajima, Hideko H.; Hamade, Mohamad A.; Mafoud, Lorice; Merchant, Gabrielle R.; Halpin, Christopher F.; Merchant, Saumil N.

    2011-01-01

    Objective This study compares measurements of ear-canal reflectance (ECR) to other objective measurements of middle-ear function including, audiometry, umbo velocity (VU), and tympanometry in a population of strictly defined normal hearing ears. Design Data were prospectively gathered from 58 ears of 29 normal hearing subjects, 16 female and 13 male, aged 22–64 years. Subjects met all of the following criteria to be considered as having normal hearing. (1) No history of significant middle-ear disease. (2) No history of otologic surgery. (3) Normal tympanic membrane (TM) on otoscopy. (4) Pure-tone audiometric thresholds of 20 dB HL or better for 0.25 – 8 kHz. (5) Air-bone gaps no greater than 15 dB at 0.25 kHz and 10 dB for 0.5 – 4 kHz. (6) Normal, type-A peaked tympanograms. (7) All subjects had two “normal” ears (as defined by these criteria). Measurements included pure-tone audiometry for 0.25 – 8 kHz, standard 226 Hz tympanometry, Ear canal reflectance(ECR) for 0.2 – 6 kHz at 60 dB SPL using the Mimosa Acoustics HearID system, and Umbo Velocity (VU ) for 0.3 – 6 kHz at 70–90 dB SPL using the HLV-1000 laser Doppler vibrometer (Polytec Inc). Results Mean power reflectance (|ECR|2) was near 1.0 at 0.2– 0.3 kHz, decreased to a broad minimum of 0.3 to 0.4 between 1 and 4 kHz, and then sharply increased to almost 0.8 by 6 kHz. The mean pressure reflectance phase angle (∠ECR) plotted on a linear frequency scale showed a group delay of approximately 0.1 ms for 0.2 – 6 kHz. Small significant differences were observed in |ECR|2 at the lowest frequencies between right and left ears, and between males and females at 4 kHz. |ECR|2 decreased with age, but reached significance only at 1 kHz. Our ECR measurements were generally similar to previous published reports. Highly significant negative correlations were found between |ECR|2 and VU for frequencies below 1 kHz. Significant correlations were also found between the tympanometrically determined peak

  20. Testing a Method for Quantifying the Output of Implantable Middle Ear Hearing Devices

    PubMed Central

    Rosowski, J.J.; Chien, W.; Ravicz, M.E.; Merchant, S.N.

    2008-01-01

    This report describes tests of a standard practice for quantifying the performance of implantable middle ear hearing devices (also known as implantable hearing aids). The standard and these tests were initiated by the Food and Drug Administration of the United States Government. The tests involved measurements on two hearing devices, one commercially available and the other home built, that were implanted into ears removed from human cadavers. The tests were conducted to investigate the utility of the practice and its outcome measures: the equivalent ear canal sound pressure transfer function that relates electrically driven middle ear velocities to the equivalent sound pressure needed to produce those velocities, and the maximum effective ear canal sound pressure. The practice calls for measurements in cadaveric ears in order to account for the varied anatomy and function of different human middle ears. PMID:17406105

  1. A Deformable Smart Skin for Continuous Sensing Based on Electrical Impedance Tomography.

    PubMed

    Visentin, Francesco; Fiorini, Paolo; Suzuki, Kenji

    2016-11-16

    In this paper, we present a low-cost, adaptable, and flexible pressure sensor that can be applied as a smart skin over both stiff and deformable media. The sensor can be easily adapted for use in applications related to the fields of robotics, rehabilitation, or costumer electronic devices. In order to remove most of the stiff components that block the flexibility of the sensor, we based the sensing capability on the use of a tomographic technique known as Electrical Impedance Tomography. The technique allows the internal structure of the domain under study to be inferred by reconstructing its conductivity map. By applying the technique to a material that changes its resistivity according to applied forces, it is possible to identify these changes and then localise the area where the force was applied. We tested the system when applied to flat and curved surfaces. For all configurations, we evaluate the artificial skin capabilities to detect forces applied over a single point, over multiple points, and changes in the underlying geometry. The results are all promising, and open the way for the application of such sensors in different robotic contexts where deformability is the key point.

  2. A Deformable Smart Skin for Continuous Sensing Based on Electrical Impedance Tomography

    PubMed Central

    Visentin, Francesco; Fiorini, Paolo; Suzuki, Kenji

    2016-01-01

    In this paper, we present a low-cost, adaptable, and flexible pressure sensor that can be applied as a smart skin over both stiff and deformable media. The sensor can be easily adapted for use in applications related to the fields of robotics, rehabilitation, or costumer electronic devices. In order to remove most of the stiff components that block the flexibility of the sensor, we based the sensing capability on the use of a tomographic technique known as Electrical Impedance Tomography. The technique allows the internal structure of the domain under study to be inferred by reconstructing its conductivity map. By applying the technique to a material that changes its resistivity according to applied forces, it is possible to identify these changes and then localise the area where the force was applied. We tested the system when applied to flat and curved surfaces. For all configurations, we evaluate the artificial skin capabilities to detect forces applied over a single point, over multiple points, and changes in the underlying geometry. The results are all promising, and open the way for the application of such sensors in different robotic contexts where deformability is the key point. PMID:27854325

  3. A 3D-printed functioning anatomical human middle ear model.

    PubMed

    Kuru, Ismail; Maier, Hannes; Müller, Mathias; Lenarz, Thomas; Lueth, Tim C

    2016-10-01

    The middle ear is a sophisticated and complex structure with a variety of functions, yet a delicate organ prone to injuries due to various reasons. Both, understanding and reconstructing its functions has always been an important topic for researchers from medical and technical background. Currently, human temporal bones are generally used as model for tests, experiments and validation of the numerical results. However, fresh human preparations are not always easily accessible and their mechanical properties vary with time and between individuals. Therefore we have built an anatomically based and functional middle ear model to serve as a reproducible test environment. Our middle ear model was manufactured with the aid of 3D-printing technology. We have segmented the essential functional elements from micro computed tomography data (μCT) of a single temporal bone. The ossicles were 3D-printed by selective laser melting (SLM) and the soft tissues were casted with silicone rubber into 3D-printed molds. The ear canal, the tympanic cavity and the inner ear were artificially designed, but their design ensured the anatomically correct position of the tympanic membrane, ossicular ligaments and the oval window. For the determination of their auditory properties we have conducted two kinds of tests: measurement of the stapes footplate response to sound and tympanometry of the model. Our experiments regarding the sound transmission showed that the model has a similar behavior to a human middle ear. The transfer function has a resonance frequency at around 1 kHz, the stapes' response is almost constant for frequencies below the resonance and a roll-off is observed above the resonance. The tympanometry results show that the compliance of the middle ear model is similar to the compliance of a healthy human middle ear. We also present that we were able to manipulate the transmission behavior, so that healthy or pathological scenarios can be created. For this purpose we have

  4. Three cases of successful microvascular ear replantation after bite avulsion injury.

    PubMed

    Schonauer, Fabrizio; Blair, James W; Moloney, Dominique M; Teo, T C; Pickford, Mark A

    2004-01-01

    We present three cases of sub-total amputation of the external ear caused by bite avulsion injury. The ears were all successfully replanted despite us being unable to perform a venous anastomosis in one case. These outcomes support attempted microsurgical replantation for total or sub-total amputations of the ear, as successful replantation is the most effective surgical option.

  5. Tomographic imaging of OH laser-induced fluorescence in laminar and turbulent jet flames

    NASA Astrophysics Data System (ADS)

    Li, Tao; Pareja, Jhon; Fuest, Frederik; Schütte, Manuel; Zhou, Yihui; Dreizler, Andreas; Böhm, Benjamin

    2018-01-01

    In this paper a new approach for 3D flame structure diagnostics using tomographic laser-induced fluorescence (Tomo-LIF) of the OH radical was evaluated. The approach combined volumetric illumination with a multi-camera detection system of eight views. Single-shot measurements were performed in a methane/air premixed laminar flame and in a non-premixed turbulent methane jet flame. 3D OH fluorescence distributions in the flames were reconstructed using the simultaneous multiplicative algebraic reconstruction technique. The tomographic measurements were compared and validated against results of OH-PLIF in the laminar flame. The effects of the experimental setup of the detection system and the size of the volumetric illumination on the quality of the tomographic reconstructions were evaluated. Results revealed that the Tomo-LIF is suitable for volumetric reconstruction of flame structures with acceptable spatial resolution and uncertainty. It was found that the number of views and their angular orientation have a strong influence on the quality and accuracy of the tomographic reconstruction while the illumination volume thickness influences mainly the spatial resolution.

  6. Concise Review: Inner Ear Stem Cells—An Oxymoron, But Why?

    PubMed Central

    Ronaghi, Mohammad; Nasr, Marjan; Heller, Stefan

    2012-01-01

    Hearing loss, caused by irreversible loss of cochlear sensory hair cells, affects millions of patients worldwide. In this concise review, we examine the conundrum of inner ear stem cells, which obviously are present in the inner ear sensory epithelia of nonmammalian vertebrates, giving these ears the ability to functionally recover even from repetitive ototoxic insults. Despite the inability of the mammalian inner ear to regenerate lost hair cells, there is evidence for cells with regenerative capacity because stem cells can be isolated from vestibular sensory epithelia and from the neonatal cochlea. Challenges and recent progress toward identification of the intrinsic and extrinsic signaling pathways that could be used to re-establish stemness in the mammalian organ of Corti are discussed. PMID:22102534

  7. Concise review: Inner ear stem cells--an oxymoron, but why?

    PubMed

    Ronaghi, Mohammad; Nasr, Marjan; Heller, Stefan

    2012-01-01

    Hearing loss, caused by irreversible loss of cochlear sensory hair cells, affects millions of patients worldwide. In this concise review, we examine the conundrum of inner ear stem cells, which obviously are present in the inner ear sensory epithelia of nonmammalian vertebrates, giving these ears the ability to functionally recover even from repetitive ototoxic insults. Despite the inability of the mammalian inner ear to regenerate lost hair cells, there is evidence for cells with regenerative capacity because stem cells can be isolated from vestibular sensory epithelia and from the neonatal cochlea. Challenges and recent progress toward identification of the intrinsic and extrinsic signaling pathways that could be used to re-establish stemness in the mammalian organ of Corti are discussed. Copyright © 2011 AlphaMed Press.

  8. [Neurological paleopathology in the pre-Columbian cultures of the coast and the Andean plateau (I). Artificial cranial deformation].

    PubMed

    Carod Artal, F J; Vázquez Cabrera, C B

    The aim of this work was to study the cranial trepanations and deformations carried out by the ancient Paraca, Huari, Tiahuanaco and Inca cultures. To do so, we conducted a field study involving visits to archaeological remains and anthropological museums on the Andean plateau and the Peruvian coast. Cranial deformation was more common in the Andean regions and was performed by putting little pieces of wood or compressive bandages on newborn infants' heads in order to modify the growth axis of the cranial cavity. Cranial deformations were performed for aesthetic and magic religious reasons, but were also used as a means of ethnic or social identification, as a symbol of nobility or to distinguish the ruling classes. The immediate consequence of such deformation was the modification of the normal process by which the cranial sutures close. There is a significant correlation between the presence of posterior and lateral wormian bones, according to the degree of artificial deformation. The persistence of metopic suture and exostosis of the outer ear canal have been found in 5% of the skulls belonging to pre Columbine mummies. Other paleopathological findings include cranial fractures (7%), porotic hyperostosis (25% of children's skulls), spina bifida occulta, signs of spinal disk arthrosis and Pott's disease. Artificial cranial deformation was a very widespread practice in the Andean regions in pre Columbine times.

  9. In vivo imaging of middle-ear and inner-ear microstructures of a mouse guided by SD-OCT combined with a surgical microscope

    PubMed Central

    Cho, Nam Hyun; Jang, Jeong Hun; Jung, Woonggyu; Kim, Jeehyun

    2014-01-01

    We developed an augmented-reality system that combines optical coherence tomography (OCT) with a surgical microscope. By sharing the common optical path in the microscope and OCT, we could simultaneously acquire OCT and microscope views. The system was tested to identify the middle-ear and inner-ear microstructures of a mouse. Considering the probability of clinical application including otorhinolaryngology, diseases such as middle-ear effusion were visualized using in vivo mouse and OCT images simultaneously acquired through the eyepiece of the surgical microscope during surgical manipulation using the proposed system. This system is expected to realize a new practical area of OCT application. PMID:24787787

  10. Effect of cochlear implantation on middle ear function: A three-month prospective study.

    PubMed

    Wasson, Joseph D; Campbell, Luke; Chambers, Scott; Hampson, Amy; Briggs, Robert J S; O'Leary, Stephen J

    2018-05-01

    To determine if cochlear implantation has a delayed effect on the middle ear conductive hearing mechanism by measuring laser Doppler vibrometry (LDV) of the tympanic membrane (TM) in both implanted and contralateral control ears preoperatively and 3 months postoperatively, and then comparing the relative change in LDV outcome measures between implanted and control ears. Prospective cohort study. Eleven preoperative adult unilateral cochlear implant recipients in previously unoperated ears with normal anatomy and aerated temporal bones were included in this study. The magnitude and phase angle of umbo velocity transfer function in response to air- conduction (AC) stimulus, and the magnitude of umbo velocity in response to bone- conduction (BC) stimulus were measured in the implant ear and the contralateral control ear preoperatively and 3 months postoperatively and compared. No significant changes in the magnitude or phase angle of TM velocity in response to either AC or BC stimulus were observed in the implanted ear relative to the contralateral control ear 3 months following cochlear implantation. From the results of LDV measurements, it can be said that cochlear implantation has no significant delayed effect on the middle ear conductive mechanism. 4. Laryngoscope, 128:1207-1212, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  11. Extracellular and intracellular melanin in inflammatory middle ear disease.

    PubMed

    Fritz, Mark A; Roehm, Pamela C; Bannan, Michael A; Lalwani, Anil K

    2014-06-01

    Melanin is a pigmented polymer with a known role in dermal solar protection. In vertebrates, melanogenesis has been reported in leukocyte populations, suggesting a potential role in innate immunity. In this study, we report the novel finding of melanin associated with chronic inflammation and speculate on its potential role in the middle ear and mastoid. Retrospective review of case series. Medical records of six patients who demonstrated melanin in the ear were reviewed. Six patients from 1 to 63 years of age were identified with extracellular melanin and melanin-laden histiocytes within the middle ear and/or mastoid air cells at time of surgery. Concurrent intraoperative findings included cholesteatoma (n = 3), chronic suppurative otitis media (n = 2), and coalescent mastoiditis (n = 1). Histologically, extracellular melanin and melanin-laden histiocytes were identified by Fontana-Masson stain; absence of melanocytes was confirmed by the absence of Melan-A staining. One patient had a positive stain for CD163 (a marker for macrophages). This case series is the first demonstration of melanin within middle ear mucosa without melanocytes in immediate proximity or metastatic melanocytic lesions. Melanin's presence in the setting of inflammation suggests that there may be a heretofore unreported link between the pigmentary and immune systems in the middle ear. 4.

  12. Long-eared owls nesting in Badlands National Park

    Treesearch

    Deborah D. Paulson; Carolyn Hull Sieg

    1985-01-01

    Long-eared Owls nest at high densities locally over the Great Plains where suitable habitat is limited (Bent 1938), yet , according to Whitney et al. (1978), this species is rare to uncommon in South Dakota. Especially west of the Missouri River, few nesting records have been reported. This paper reports the occurrence of Long-eared Owls in the Badlands National Park...

  13. Tomographic phase microscopy: principles and applications in bioimaging [Invited

    PubMed Central

    Jin, Di; Zhou, Renjie; Yaqoob, Zahid; So, Peter T. C.

    2017-01-01

    Tomographic phase microscopy (TPM) is an emerging optical microscopic technique for bioimaging. TPM uses digital holographic measurements of complex scattered fields to reconstruct three-dimensional refractive index (RI) maps of cells with diffraction-limited resolution by solving inverse scattering problems. In this paper, we review the developments of TPM from the fundamental physics to its applications in bioimaging. We first provide a comprehensive description of the tomographic reconstruction physical models used in TPM. The RI map reconstruction algorithms and various regularization methods are discussed. Selected TPM applications for cellular imaging, particularly in hematology, are reviewed. Finally, we examine the limitations of current TPM systems, propose future solutions, and envision promising directions in biomedical research. PMID:29386746

  14. [Facial nerve monitoring during middle ear surgery: Results of a French survey].

    PubMed

    Mazzaschi, O; Juvanon, J-M; Mondain, M; Lavieile, J-P; Ayache, D

    2014-01-01

    Facial nerve injury is a rare complication of middle ear surgery. To date there is no widely accepted consensus on the use of intraoperative facial nerve monitoring during middle ear surgery, whereas its use has been proved as a valuable adjunct in neurotologic surgery. The purpose of our study was to identify introperative facial nerve monitoring practice patterns in France for middle ear surgery. A 19-item survey has been made up by three experienced otologists under the auspices of the French Otology and Neurotology Association. With the support of the French Society of Otolaryngology--Head and Neck Surgery, the survey was electronically sent by email to 1249 practicing ENT with a valid email address. Answers were analyzed two months later. Among 1249 email sent, 299 were opened (24%) and 83 answers were collected (6,6%). Of the respondents, 66% had access to intraoperative facial nerve monitoring. Otolaryngologists involved in academic setting were influenced by their teaching duty in 27%. Intraoperative facial nerve monitoring should not be required for stapes surgery, ossiculoplasty, myringoplasty for, respectively, 92%, 93 % and 98% of the respondents. In cochlear implantation, 78% of ear surgeons used facial nerve monitoring. Answers were more controversial for chronic ear surgery, ear atresia and middle ear implant. Revision surgery and CT scan can influence answers. Despite a low response rate, results of this national survey revealed interesting findings. For most of the respondents, intraoperative facial nerve monitoring was not indicated in stapes surgery, myringoplasty and ossiculoplasty. The use of intraoperative facial nerve monitoring for cochlear implantation was supported by the majority of respondents. Variations in response rate were more significant for chronic ear surgery, including middle ear cholesteatoma, and for ear atresia surgery.

  15. Effect of target-masker similarity on across-ear interference in a dichotic cocktail-party listening task.

    PubMed

    Brungart, Douglas S; Simpson, Brian D

    2007-09-01

    Similarity between the target and masking voices is known to have a strong influence on performance in monaural and binaural selective attention tasks, but little is known about the role it might play in dichotic listening tasks with a target signal and one masking voice in the one ear and a second independent masking voice in the opposite ear. This experiment examined performance in a dichotic listening task with a target talker in one ear and same-talker, same-sex, or different-sex maskers in both the target and the unattended ears. The results indicate that listeners were most susceptible to across-ear interference with a different-sex within-ear masker and least susceptible with a same-talker within-ear masker, suggesting that the amount of across-ear interference cannot be predicted from the difficulty of selectively attending to the within-ear masking voice. The results also show that the amount of across-ear interference consistently increases when the across-ear masking voice is more similar to the target speech than the within-ear masking voice is, but that no corresponding decline in across-ear interference occurs when the across-ear voice is less similar to the target than the within-ear voice. These results are consistent with an "integrated strategy" model of speech perception where the listener chooses a segregation strategy based on the characteristics of the masker present in the target ear and the amount of across-ear interference is determined by the extent to which this strategy can also effectively be used to suppress the masker in the unattended ear.

  16. An abbreviated history of the ear: from Renaissance to present.

    PubMed Central

    Hachmeister, Jorge E.

    2003-01-01

    In this article we discuss important discoveries in relation to the anatomy and physiology of the ear from Renaissance to present. Before the Renaissance, there was a paucity of knowledge of the anatomy of the ear, because of the relative inaccessibility of the temporal bone and the general perception that human dissections should not be conducted. It was not until the sixteenth century that the middle ear was described with detail. Further progress would be made between the sixteenth and eighteenth century in describing the inner ear. In the nineteenth century, technological advancement permitted a description of the cells and structures that constitute the cochlea. Von Helmholtz made further progress in hearing physiology when he postulated his resonance theory and later von Békésy when he observed a traveling wave in human cadavers within the cochlea. Brownell later made a major advance when he discovered that the ear has a mechanism for sound amplification, via outer hair cell electromotility. Images Figure 1 Figure 2 PMID:15369636

  17. Optical tomograph optimized for tumor detection inside highly absorbent organs

    NASA Astrophysics Data System (ADS)

    Boutet, Jérôme; Koenig, Anne; Hervé, Lionel; Berger, Michel; Dinten, Jean-Marc; Josserand, Véronique; Coll, Jean-Luc

    2011-05-01

    This paper presents a tomograph for small animal fluorescence imaging. The compact and cost-effective system described in this article was designed to address the problem of tumor detection inside highly absorbent heterogeneous organs, such as lungs. To validate the tomograph's ability to detect cancerous nodules inside lungs, in vivo tumor growth was studied on seven cancerous mice bearing murine mammary tumors marked with Alexa Fluor 700. They were successively imaged 10, 12, and 14 days after the primary tumor implantation. The fluorescence maps were compared over this time period. As expected, the reconstructed fluorescence increases with the tumor growth stage.

  18. Lamb wave tomographic imaging system for aircraft structural health assessment

    NASA Astrophysics Data System (ADS)

    Schwarz, Willi G.; Read, Michael E.; Kremer, Matthew J.; Hinders, Mark K.; Smith, Barry T.

    1999-01-01

    A tomographic imaging system using ultrasonic Lamb waves for the nondestructive inspection of aircraft components such as wings and fuselage is being developed. The computer-based system provides large-area inspection capability by electronically scanning an array of transducers that can be easily attached to flat and curved surface without moving parts. Images of the inspected area are produced in near real time employing a tomographic reconstruction method adapted from seismological applications. Changes in material properties caused by structural flaws such as disbonds, corrosion, and fatigue cracks can be effectively detected and characterized utilizing this fast NDE technique.

  19. Analysis of 21-cm tomographic data

    NASA Astrophysics Data System (ADS)

    Mellema, Garrelt; Giri, Sambit; Ghara, Raghuna

    2018-05-01

    The future SKA1-Low radio telescope will be powerful enough to produce tomographic images of the 21-cm signal from the Epoch of Reionization. Here we address how to identify ionized regions in such data sets, taking into account the resolution and noise levels associated with SKA1-Low. We describe three methods of which one, superpixel oversegmentation, consistently performs best.

  20. TomoBank: a tomographic data repository for computational x-ray science

    DOE PAGES

    De Carlo, Francesco; Gürsoy, Doğa; Ching, Daniel J.; ...

    2018-02-08

    There is a widening gap between the fast advancement of computational methods for tomographic reconstruction and their successful implementation in production software at various synchrotron facilities. This is due in part to the lack of readily available instrument datasets and phantoms representative of real materials for validation and comparison of new numerical methods. Recent advancements in detector technology made sub-second and multi-energy tomographic data collection possible [1], but also increased the demand to develop new reconstruction methods able to handle in-situ [2] and dynamic systems [3] that can be quickly incorporated in beamline production software [4]. The X-ray Tomography Datamore » Bank, tomoBank, provides a repository of experimental and simulated datasets with the aim to foster collaboration among computational scientists, beamline scientists, and experimentalists and to accelerate the development and implementation of tomographic reconstruction methods for synchrotron facility production software by providing easy access to challenging dataset and their descriptors.« less

  1. Preventing Cauliflower Ear with a Modified Tie-Through Technique.

    ERIC Educational Resources Information Center

    Dimeff, Robert J.; Hough, David O.

    1989-01-01

    Describes a quick, simple tie-through suture technique (in which a collodion packing is secured to the auricle with two buttons) for preventing cauliflower ear following external ear trauma in wrestlers and boxers. The technique ensures constant compression; multiple treatments for fluid reaccumulation are rarely necessary. (SM)

  2. Surgical correction of the expanded earlobe after ear gauging.

    PubMed

    Henderson, James; Malata, Charles M

    2010-10-01

    Expansion of the earlobe by ear gauging or plugging is an increasingly fashionable practice. As patients get older, some seek to have their ears restored to normal. This report presents a simple local flap technique that has been successful in achieving uneventful healing with acceptable cosmetic results.

  3. Revisiting gender, race, and ear differences in peripheral auditory function

    NASA Astrophysics Data System (ADS)

    Boothalingam, Sriram; Klyn, Niall A. M.; Stiepan, Samantha M.; Wilson, Uzma S.; Lee, Jungwha; Siegel, Jonathan H.; Dhar, Sumitrajit

    2018-05-01

    Various measures of auditory function are reported to be superior in females as compared to males, in African American compared to Caucasian individuals, and in right compared to left ears. We re-examined the influence of these subject variables on hearing thresholds and otoacoustic emissions (OAEs) in a sample of 887 human participants between 10 and 68 years of age. Even though the variables of interest here have been examined before, previous attempts have largely been limited to frequencies up to 8 kHz. We used state-of-the-art signal delivery and recording techniques that compensated for individual differences in ear canal acoustics, allowing us to measure hearing thresholds and OAEs up to 20 kHz. The use of these modern calibration and recording techniques provided the motivation for re-examining these commonly studied variables. While controlling for age, noise exposure history, and general health history, we attempted to isolate the effects of gender, race, and ear (left versus right) on hearing thresholds and OAEs. Our results challenge the notion of a right ear advantage and question the existence of a significant gender and race differences in both hearing thresholds and OAE levels. These results suggest that ear canal anatomy and acoustics should be important considerations when evaluating the influence of gender, race, and ear on peripheral auditory function.

  4. Development of a finite element model of the middle ear.

    PubMed

    Williams, K R; Blayney, A W; Rice, H J

    1996-01-01

    A representative finite element model of the healthy ear is developed commencing with a description of the decoupled isotropic tympanic membrane. This model was shown to vibrate in a manner similar to that found both numerically (1, 2) and experimentally (8). The introduction of a fibre system into the membrane matrix significantly altered the modes of vibration. The first mode "remains as a piston like movement as for the isotropic membrane. However, higher modes show a simpler vibration pattern similar to the second mode but with a varying axis of movement and lower amplitudes. The introduction of a malleus and incus does not change the natural frequencies or mode shapes of the membrane for certain support conditions. When constraints are imposed along the ossicular chain by simulation of a cochlear impedance term then significantly altered modes can occur. More recently a revised model of the ear has been developed by the inclusion of the outer ear canal. This discretisation uses geometries extracted from a Nuclear Magnetic resonance scan of a healthy subject and a crude inner ear model using stiffness parameters ultimately fixed through a parameter tuning process. The subsequently tuned model showed behaviour consistent with previous findings and should provide a good basis for subsequent modelling of diseased ears and assessment of the performance of middle ear prostheses.

  5. Zebrafish models of human eye and inner ear diseases.

    PubMed

    Blanco-Sánchez, B; Clément, A; Phillips, J B; Westerfield, M

    2017-01-01

    Eye and inner ear diseases are the most common sensory impairments that greatly impact quality of life. Zebrafish have been intensively employed to understand the fundamental mechanisms underlying eye and inner ear development. The zebrafish visual and vestibulo-acoustic systems are very similar to these in humans, and although not yet mature, they are functional by 5days post-fertilization (dpf). In this chapter, we show how the zebrafish has significantly contributed to the field of biomedical research and how researchers, by establishing disease models and meticulously characterizing their phenotypes, have taken the first steps toward therapies. We review here models for (1) eye diseases, (2) ear diseases, and (3) syndromes affecting eye and/or ear. The use of new genome editing technologies and high-throughput screening systems should increase considerably the speed at which knowledge from zebrafish disease models is acquired, opening avenues for better diagnostics, treatments, and therapies. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Pathogenesis of Middle Ear Cholesteatoma

    PubMed Central

    Yamamoto-Fukuda, Tomomi; Hishikawa, Yoshitaka; Shibata, Yasuaki; Kobayashi, Toshimitsu; Takahashi, Haruo; Koji, Takehiko

    2010-01-01

    Middle ear cholesteatoma is characterized by enhanced proliferation of epithelial cells with aberrant morphological characteristics. To investigate the origin of the cholesteatoma cells, we analyzed spontaneously occurring cholesteatomas associated with a new transplantation model in Mongolian gerbils (gerbils). Cholesteatomas were induced in gerbils with a transplanted tympanic membrane by using the external auditory canal (EAC) ligation method. After the pars flaccida of the tympanic membranes were completely removed from male gerbils, corresponding portions of tympanic membranes of female gerbils were transplanted to the area of defect, and then we ligated the EAC (hybrid-model group). As a control group, the EAC of normal male and female gerbils was ligated without myringoplasty. In all ears of each group, the induced cholesteatomas were seen. In situ PCR was then performed to detect the mouse X chromosome-linked phosphoglycerate kinase-1 (pgk-1) gene on the paraffin sections. One pgk-1 spot in the epithelial nuclei was detected in male cholesteatoma, and two pgk-1 spots were detected in female cholesteatoma, respectively. On the other hand, in the hybrid-model group, we detected not only one but also two pgk-1 spots in the epithelial nuclei of cholesteatoma. These results strengthened the evidence that the origin of epithelial cells in cholesteatoma is the tympanic membrane in this model, but not the residential middle ear epithelial cells or the skin of the EAC. PMID:20413684

  7. Relative size of auditory pathways in symmetrically and asymmetrically eared owls.

    PubMed

    Gutiérrez-Ibáñez, Cristián; Iwaniuk, Andrew N; Wylie, Douglas R

    2011-01-01

    Owls are highly efficient predators with a specialized auditory system designed to aid in the localization of prey. One of the most unique anatomical features of the owl auditory system is the evolution of vertically asymmetrical ears in some species, which improves their ability to localize the elevational component of a sound stimulus. In the asymmetrically eared barn owl, interaural time differences (ITD) are used to localize sounds in azimuth, whereas interaural level differences (ILD) are used to localize sounds in elevation. These two features are processed independently in two separate neural pathways that converge in the external nucleus of the inferior colliculus to form an auditory map of space. Here, we present a comparison of the relative volume of 11 auditory nuclei in both the ITD and the ILD pathways of 8 species of symmetrically and asymmetrically eared owls in order to investigate evolutionary changes in the auditory pathways in relation to ear asymmetry. Overall, our results indicate that asymmetrically eared owls have much larger auditory nuclei than owls with symmetrical ears. In asymmetrically eared owls we found that both the ITD and ILD pathways are equally enlarged, and other auditory nuclei, not directly involved in binaural comparisons, are also enlarged. We suggest that the hypertrophy of auditory nuclei in asymmetrically eared owls likely reflects both an improved ability to precisely locate sounds in space and an expansion of the hearing range. Additionally, our results suggest that the hypertrophy of nuclei that compute space may have preceded that of the expansion of the hearing range and evolutionary changes in the size of the auditory system occurred independently of phylogeny. Copyright © 2011 S. Karger AG, Basel.

  8. Modeling Analysis of Biomechanical Changes of Middle Ear and Cochlea in Otitis Media

    NASA Astrophysics Data System (ADS)

    Gan, Rong Z.; Zhang, Xiangming; Guan, Xiying

    2011-11-01

    A comprehensive finite element (FE) model of the human ear including the ear canal, middle ear, and spiral cochlea was developed using histological sections of human temporal bone. The cochlea was modeled with three chambers separated by the basilar membrane and Reissner's membrane and filled with perilymphatic fluid. The viscoelastic material behavior was applied to middle ear soft tissues based on dynamic measurements of tissues in our lab. The model was validated using the experimental data obtained in human temporal bones and then used to simulate various stages of otitis media (OM) including the changes of morphology, mechanical properties, pressure, and fluid level in the middle ear. Function alterations of the middle ear and cochlea in OM were derived from the model and compared with the measurements from temporal bones. This study indicates that OM can be simulated in the FE model to predict the hearing loss induced by biomechanical changes of the middle ear and cochlea.

  9. Reconstruction following traumatic partial amputation of the ear.

    PubMed

    Pearl, Robert A; Sabbagh, Walid

    2011-02-01

    Reconstruction following traumatic amputation of the external ear remains a unique challenge to the plastic surgeon. The authors report a series of ear reconstructions with autologous costal cartilage in patients following traumatic partial amputation of the ear. Technical points regarding the carving of the cartilage framework and methods of skin coverage are discussed. Fifty partial ear reconstructions with autologous costal cartilage were performed over a 4-year period. All patients had suffered previous traumatic amputation of part of the external auricle due to bite injuries (n = 36), road traffic accidents (n = 6), burns (n = 5), or torture (n = 3). A two-stage technique of reconstruction with autologous cartilage graft was used based on Nagata's adaptations of Brent's original technique. In nine cases, skin shortage or extensive scarring required preoperative tissue expansion (n = 4) or a temporoparietal fascial flap (n = 5) to provide adequate coverage of the cartilage framework. Forty-seven patients had a successful surgical outcome without complication. Two patients developed small areas of skin necrosis resulting in exposure of the cartilage framework. These healed with conservative management with minor loss of definition. One case of wound infection resulted in significant loss of definition of the construct, which required a further surgical procedure with additional costal cartilage graft. Reconstruction of the external ear with autologous costal cartilage following traumatic amputation can produce high-quality auricles consistently and is becoming the treatment of choice for such injuries, given access to a specialist center with exposure to a high volume of cases.

  10. Ear surgery techniques results on hearing threshold improvement

    PubMed Central

    Mokhtarinejad, Farhad; Pour, Saeed Soheili; Nilforoush, Mohammad Hussein; Sepehrnejad, Mahsa; Mirelahi, Susan

    2013-01-01

    Background: Bone conduction (BC) threshold depression is not always by means of sensory neural hearing loss and sometimes it is an artifact caused by middle ear pathologies and ossicular chain problems. In this research, the influences of ear surgeries on bone conduction were evaluated. Materials and Methods: This study was conducted as a clinical trial study. The ear surgery performed on 83 patients classified in four categories: Stapedectomy, tympanomastoid surgery and ossicular reconstruction partially or totally; Partial Ossicular Replacement Prosthesis (PORP) and Total Ossicular Replacement Prosthesis (TORP). Bone conduction thresholds assessed in frequencies of 250, 500, 1000, 2000 and 4000 Hz pre and post the surgery. Results: In stapedectomy group, the average of BC threshold in all frequencies improved approximately 6 dB in frequency of 2000 Hz. In tympanomastoid group, BC threshold in the frequency of 500, 1000 and 2000 Hz changed 4 dB (P-value < 0.05). Moreover, In the PORP group, 5 dB enhancement was seen in 1000 and 2000 Hz. In TORP group, the results confirmed that BC threshold improved in all frequencies especially at 4000 Hz about 6.5 dB. Conclusion: In according to results of this study, BC threshold shift was seen after several ear surgeries such as stapedectomy, tympanoplasty, PORP and TORP. The average of BC improvement was approximately 5 dB. It must be considered that BC depression might happen because of ossicular chain problems. Therefore; by resolving middle ear pathologies, the better BC threshold was obtained, the less hearing problems would be faced. PMID:24381615

  11. An investigation of ear necrosis in pigs.

    PubMed

    Park, Jeonghwa; Friendship, Robert M; Poljak, Zvonimir; DeLay, Josepha; Slavic, Durda; Dewey, Catherine E

    2013-05-01

    Porcine ear necrosis was investigated in 23 conveniently chosen farms, consisting of 14 case farms and 9 control farms. Biopsies of lesions and oral swabs from pigs on 11 case farms were examined by histology and bacterial culture. All farms were visited for observations and a survey on management, housing, and the presence of other clinical signs or behavioral vices. Histological examination revealed that the lesions began on the surface and progressed to deeper layers, and that vascular damage did not appear to be the initiating cause. Spirochetes were only rarely observed in histological examination and were not cultured from biopsies and oral swabs. Staphylococcus aureus and Staphylococcus hyicus were cultured from 91% and 66% of samples, respectively. Ear biting and a humid environment were associated with ear necrosis. On some farms large numbers of pigs were affected and lesions were sometimes extensive. The condition appears to be an infectious disease beginning on the surface of the skin; contributing environmental and management factors are likely.

  12. An investigation of ear necrosis in pigs

    PubMed Central

    Park, Jeonghwa; Friendship, Robert M.; Poljak, Zvonimir; DeLay, Josepha; Slavic, Durda; Dewey, Catherine E.

    2013-01-01

    Porcine ear necrosis was investigated in 23 conveniently chosen farms, consisting of 14 case farms and 9 control farms. Biopsies of lesions and oral swabs from pigs on 11 case farms were examined by histology and bacterial culture. All farms were visited for observations and a survey on management, housing, and the presence of other clinical signs or behavioral vices. Histological examination revealed that the lesions began on the surface and progressed to deeper layers, and that vascular damage did not appear to be the initiating cause. Spirochetes were only rarely observed in histological examination and were not cultured from biopsies and oral swabs. Staphylococcus aureus and Staphylococcus hyicus were cultured from 91% and 66% of samples, respectively. Ear biting and a humid environment were associated with ear necrosis. On some farms large numbers of pigs were affected and lesions were sometimes extensive. The condition appears to be an infectious disease beginning on the surface of the skin; contributing environmental and management factors are likely. PMID:24155434

  13. A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology

    NASA Astrophysics Data System (ADS)

    Staton, R. J.; Pazik, F. D.; Nipper, J. C.; Williams, J. L.; Bolch, W. E.

    2003-04-01

    Establishment of organ doses from diagnostic and interventional examinations is a key component to quantifying the radiation risks from medical exposures and for formulating corresponding dose-reduction strategies. Radiation transport models of human anatomy provide a convenient method for simulating radiological examinations. At present, two classes of models exist: stylized mathematical models and tomographic voxel models. In the present study, organ dose comparisons are made for projection radiographs of both a stylized and a tomographic model of the newborn patient. Sixteen separate radiographs were simulated for each model at x-ray technique factors typical of newborn examinations: chest, abdomen, thorax and head views in the AP, PA, left LAT and right LAT projection orientation. For AP and PA radiographs of the torso (chest, abdomen and thorax views), the effective dose assessed for the tomographic model exceeds that for the stylized model with per cent differences ranging from 19% (AP abdominal view) to 43% AP chest view. In contrast, the effective dose for the stylized model exceeds that for the tomographic model for all eight lateral views including those of the head, with per cent differences ranging from 9% (LLAT chest view) to 51% (RLAT thorax view). While organ positioning differences do exist between the models, a major factor contributing to differences in effective dose is the models' exterior trunk shape. In the tomographic model, a more elliptical shape is seen thus providing for less tissue shielding for internal organs in the AP and PA directions, with corresponding increased tissue shielding in the lateral directions. This observation is opposite of that seen in comparisons of stylized and tomographic models of the adult.

  14. Ototoxicity (Ear Poisoning) (For Parents)

    MedlinePlus

    ... never change the dose or stop giving your child a medicine without talking to your doctor first. Reviewed by: Robert C. ... Hearing Loss? Can Loud Music Hurt My Ears? Going to the Audiologist Hearing ...

  15. Management of prominent ears: personal approach.

    PubMed

    Pérez-Macias, José Manuel

    2008-03-01

    Various methods for correcting prominent ears have been reported. Although anterior cartilage antihelix abrasion combined with posterior retention sutures is a conventional procedure, it does not include anterior conchal cartilage abrasion and thus allows easier reduction of the condromastoid angle. A simple and effective technique is described that involves using a rasp to score the whole anterior surface of the auricular cartilage, including the concha, in combination with Mustarde-type conchal-antihelical and conchal-mastoid retention sutures. This method was applied to 342 patients (675 ears) over 23 years, who were followed up for periods varying from 18 to 24 months. Good results were obtained for all patients with minimal complications.

  16. Air-Leak Effects on Ear-Canal Acoustic Absorbance

    PubMed Central

    Rasetshwane, Daniel M.; Kopun, Judy G.; Gorga, Michael P.; Neely, Stephen T.

    2015-01-01

    Objective: Accurate ear-canal acoustic measurements, such as wideband acoustic admittance, absorbance, and otoacoustic emissions, require that the measurement probe be tightly sealed in the ear canal. Air leaks can compromise the validity of the measurements, interfere with calibrations, and increase variability. There are no established procedures for determining the presence of air leaks or criteria for what size leak would affect the accuracy of ear-canal acoustic measurements. The purpose of this study was to determine ways to quantify the effects of air leaks and to develop objective criteria to detect their presence. Design: Air leaks were simulated by modifying the foam tips that are used with the measurement probe through insertion of thin plastic tubing. To analyze the effect of air leaks, acoustic measurements were taken with both modified and unmodified foam tips in brass-tube cavities and human ear canals. Measurements were initially made in cavities to determine the range of critical leaks. Subsequently, data were collected in ears of 21 adults with normal hearing and normal middle-ear function. Four acoustic metrics were used for predicting the presence of air leaks and for quantifying these leaks: (1) low-frequency admittance phase (averaged over 0.1–0.2 kHz), (2) low-frequency absorbance, (3) the ratio of compliance volume to physical volume (CV/PV), and (4) the air-leak resonance frequency. The outcome variable in this analysis was the absorbance change (Δabsorbance), which was calculated in eight frequency bands. Results: The trends were similar for both the brass cavities and the ear canals. ΔAbsorbance generally increased with air-leak size and was largest for the lower frequency bands (0.1–0.2 and 0.2–0.5 kHz). Air-leak effects were observed in frequencies up to 10 kHz, but their effects above 1 kHz were unpredictable. These high-frequency air leaks were larger in brass cavities than in ear canals. Each of the four predictor variables

  17. Air-leak effects on ear-canal acoustic absorbance.

    PubMed

    Groon, Katherine A; Rasetshwane, Daniel M; Kopun, Judy G; Gorga, Michael P; Neely, Stephen T

    2015-01-01

    Accurate ear-canal acoustic measurements, such as wideband acoustic admittance, absorbance, and otoacoustic emissions, require that the measurement probe be tightly sealed in the ear canal. Air leaks can compromise the validity of the measurements, interfere with calibrations, and increase variability. There are no established procedures for determining the presence of air leaks or criteria for what size leak would affect the accuracy of ear-canal acoustic measurements. The purpose of this study was to determine ways to quantify the effects of air leaks and to develop objective criteria to detect their presence. Air leaks were simulated by modifying the foam tips that are used with the measurement probe through insertion of thin plastic tubing. To analyze the effect of air leaks, acoustic measurements were taken with both modified and unmodified foam tips in brass-tube cavities and human ear canals. Measurements were initially made in cavities to determine the range of critical leaks. Subsequently, data were collected in ears of 21 adults with normal hearing and normal middle-ear function. Four acoustic metrics were used for predicting the presence of air leaks and for quantifying these leaks: (1) low-frequency admittance phase (averaged over 0.1-0.2 kHz), (2) low-frequency absorbance, (3) the ratio of compliance volume to physical volume (CV/PV), and (4) the air-leak resonance frequency. The outcome variable in this analysis was the absorbance change (Δabsorbance), which was calculated in eight frequency bands. The trends were similar for both the brass cavities and the ear canals. ΔAbsorbance generally increased with air-leak size and was largest for the lower frequency bands (0.1-0.2 and 0.2-0.5 kHz). Air-leak effects were observed in frequencies up to 10 kHz, but their effects above 1 kHz were unpredictable. These high-frequency air leaks were larger in brass cavities than in ear canals. Each of the four predictor variables exhibited consistent dependence on

  18. Big Stimulus, Little Ears: Safety in Administering Vestibular-Evoked Myogenic Potentials in Children.

    PubMed

    Thomas, Megan L A; Fitzpatrick, Denis; McCreery, Ryan; Janky, Kristen L

    2017-05-01

    Cervical and ocular vestibular-evoked myogenic potentials (VEMPs) have become common clinical vestibular assessments. However, VEMP testing requires high intensity stimuli, raising concerns regarding safety with children, where sound pressure levels may be higher due to their smaller ear canal volumes. The purpose of this study was to estimate the range of peak-to-peak equivalent sound pressure levels (peSPLs) in child and adult ears in response to high intensity stimuli (i.e., 100 dB normal hearing level [nHL]) commonly used for VEMP testing and make a determination of whether acoustic stimuli levels with VEMP testing are safe for use in children. Prospective experimental. Ten children (4-6 years) and ten young adults (24-35 years) with normal hearing sensitivity and middle ear function participated in the study. Probe microphone peSPL measurements of clicks and 500 Hz tonebursts (TBs) were recorded in tubes of small, medium, and large diameter, and in a Brüel & Kjær Ear Simulator Type 4157 to assess for linearity of the stimulus at high levels. The different diameter tubes were used to approximate the range of cross-sectional areas in infant, child, and adult ears, respectively. Equivalent ear canal volume and peSPL measurements were then recorded in child and adult ears. Lower intensity levels were used in the participant's ears to limit exposure to high intensity sound. The peSPL measurements in participant ears were extrapolated using predictions from linear mixed models to determine if equivalent ear canal volume significantly contributed to overall peSPL and to estimate the mean and 95% confidence intervals of peSPLs in child and adult ears when high intensity stimulus levels (100 dB nHL) are used for VEMP testing without exposing subjects to high-intensity stimuli. Measurements from the coupler and tubes suggested: 1) each stimuli was linear, 2) there were no distortions or nonlinearities at high levels, and 3) peSPL increased with decreased tube diameter

  19. Promoting Collaborative Playful Experimentation through Group Playing by Ear in Higher Education

    ERIC Educational Resources Information Center

    Varvarigou, Maria

    2017-01-01

    A group of 46, first-year, primarily classically trained, undergraduate students took part in an exploratory research study on Group Ear Playing (GEP) in higher education. The students attended the "Playing by Ear" component of the Practical Musicianship module, which adopts the materials and strategies on playing by ear in the…

  20. Tail Docking and Ear Cropping Dogs: Public Awareness and Perceptions

    PubMed Central

    Mills, Katelyn E.; Robbins, Jesse; von Keyserlingk, Marina A. G.

    2016-01-01

    Tail docking and ear cropping are two surgical procedures commonly performed on many dog breeds. These procedures are classified as medically unnecessary surgeries whose purpose is primarily cosmetic. Available attitude research surrounding these controversial practices has been limited to surveys of veterinarians and dog breeders familiar with both practices. The aim of this project was to: 1) assess public awareness of tail docking and ear cropping, 2) determine whether physical alteration of a dog affects how the dog, and 3) owner are perceived. In Experiment 1 awareness was measured using a combination of both explicit and implicit measures. We found that 42% of participants (n = 810) were unable to correctly explain the reason why tail docked and ear cropped dogs had short ears and tails. Similarly, an implicit measure of awareness (‘nature vs nurture task’), found that the majority of participants believed short tails and erect ears were a consequence of genetics rather than something the owner or breeder had done. The results obtained in Experiment 2 (n = 392) provide evidence that ear cropped and tail docked dogs are perceived differently than an identical dog in its ‘natural’ state. Modified dogs were perceived as being more aggressive, more dominant, less playful and less attractive than natural dogs. Experiment 3 (n = 410) is the first evidence that owners of modified dogs are perceived as being more aggressive, more narcissistic, less playful, less talkative and less warm compared to owners of natural dogs. Taken together, these results suggest that although a significant proportion of subjects appear unaware of the practices of tail docking and ear cropping in dogs, these procedures have significant impacts on how modified dogs and their owners are perceived by others. PMID:27348817

  1. Right Ear Advantage of Speech Audiometry in Single-sided Deafness.

    PubMed

    Wettstein, Vincent G; Probst, Rudolf

    2018-04-01

    Postlingual single-sided deafness (SSD) is defined as normal hearing in one ear and severely impaired hearing in the other ear. A right ear advantage and dominance of the left hemisphere are well established findings in individuals with normal hearing and speech processing. Therefore, it seems plausible that a right ear advantage would exist in patients with SSD. The audiometric database was searched to identify patients with SSD. Results from the German monosyllabic Freiburg word test and four-syllabic number test in quiet were evaluated. Results of right-sided SSD were compared with left-sided SSD. Statistical calculations were done with the Mann-Whitney U test. Four hundred and six patients with SSD were identified, 182 with right-sided and 224 with left-sided SSD. The two groups had similar pure-tone thresholds without significant differences. All test parameters of speech audiometry had better values for right ears (SSD left) when compared with left ears (SSD right). Statistically significant results (p < 0.05) were found for a weighted score (social index, 98.2 ± 4% right and 97.5 ± 4.7% left, p < 0.026), for word understanding at 60 dB SPL (95.2 ± 8.7% right and 93.9 ± 9.1% left, p < 0.035), and for the level at which 100% understanding was reached (61.5 ± 10.1 dB SPL right and 63.8 ± 11.1 dB SPL left, p < 0.022) on a performance-level function. A right ear advantage of speech audiometry was found in patients with SSD in this retrospective study of audiometric test results.

  2. Tail Docking and Ear Cropping Dogs: Public Awareness and Perceptions.

    PubMed

    Mills, Katelyn E; Robbins, Jesse; von Keyserlingk, Marina A G

    2016-01-01

    Tail docking and ear cropping are two surgical procedures commonly performed on many dog breeds. These procedures are classified as medically unnecessary surgeries whose purpose is primarily cosmetic. Available attitude research surrounding these controversial practices has been limited to surveys of veterinarians and dog breeders familiar with both practices. The aim of this project was to: 1) assess public awareness of tail docking and ear cropping, 2) determine whether physical alteration of a dog affects how the dog, and 3) owner are perceived. In Experiment 1 awareness was measured using a combination of both explicit and implicit measures. We found that 42% of participants (n = 810) were unable to correctly explain the reason why tail docked and ear cropped dogs had short ears and tails. Similarly, an implicit measure of awareness ('nature vs nurture task'), found that the majority of participants believed short tails and erect ears were a consequence of genetics rather than something the owner or breeder had done. The results obtained in Experiment 2 (n = 392) provide evidence that ear cropped and tail docked dogs are perceived differently than an identical dog in its 'natural' state. Modified dogs were perceived as being more aggressive, more dominant, less playful and less attractive than natural dogs. Experiment 3 (n = 410) is the first evidence that owners of modified dogs are perceived as being more aggressive, more narcissistic, less playful, less talkative and less warm compared to owners of natural dogs. Taken together, these results suggest that although a significant proportion of subjects appear unaware of the practices of tail docking and ear cropping in dogs, these procedures have significant impacts on how modified dogs and their owners are perceived by others.

  3. Intravenous volume tomographic pulmonary angiography imaging

    NASA Astrophysics Data System (ADS)

    Ning, Ruola; Strang, John G.; Chen, Biao; Conover, David L.; Yu, Rongfeng

    1999-05-01

    This study presents a new intravenous (IV) tomographic angiography imaging technique, called intravenous volume tomographic digital angiography (VTDA) for cross sectional pulmonary angiography. While the advantages of IV-VTDA over spiral CT in terms of volume scanning time and resolution have been validated and reported in our previous papers for head and neck vascular imaging, the superiority of IV-VTDA over spiral CT for cross sectional pulmonary angiography has not been explored yet. The purpose of this study is to demonstrate the advantage of isotropic resolution of IV-VTDA in the x, y and z directions through phantom and animal studies, and to explore its clinical application for detecting clots in pulmonary angiography. A prototype image intensifier-based VTDA imaging system has been designed and constructed by modifying a GE 8800 CT scanner. This system was used for a series of phantom and dog studies. A pulmonary vascular phantom was designed and constructed. The phantom was scanned using the prototype VTDA system for direct 3D reconstruction. Then the same phantom was scanned using a GE CT/i spiral CT scanner using the routine pulmonary CT angiography protocols. IV contrast injection and volume scanning protocols were developed during the dog studies. Both VTDA reconstructed images and spiral CT images of the specially designed phantom were analyzed and compared. The detectability of simulated vessels and clots was assessed as the function of iodine concentration levels, oriented angles, and diameters of the vessels and clots. A set of 3D VTDA reconstruction images of dog pulmonary arteries was obtained with different IV injection rates and isotropic resolution in the x, y and z directions. The results of clot detection studies in dog pulmonary arteries have also been shown. This study presents a new tomographic IV angiography imaging technique for cross sectional pulmonary angiography. The results of phantom and animal studies indicate that IV-VTDA is

  4. Tomographic Neutron Imaging using SIRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gregor, Jens; FINNEY, Charles E A; Toops, Todd J

    2013-01-01

    Neutron imaging is complementary to x-ray imaging in that materials such as water and plastic are highly attenuating while material such as metal is nearly transparent. We showcase tomographic imaging of a diesel particulate filter. Reconstruction is done using a modified version of SIRT called PSIRT. We expand on previous work and introduce Tikhonov regularization. We show that near-optimal relaxation can still be achieved. The algorithmic ideas apply to cone beam x-ray CT and other inverse problems.

  5. Auditory Brainstem Circuits That Mediate the Middle Ear Muscle Reflex

    PubMed Central

    Mukerji, Sudeep; Windsor, Alanna Marie; Lee, Daniel J.

    2010-01-01

    The middle ear muscle (MEM) reflex is one of two major descending systems to the auditory periphery. There are two middle ear muscles (MEMs): the stapedius and the tensor tympani. In man, the stapedius contracts in response to intense low frequency acoustic stimuli, exerting forces perpendicular to the stapes superstructure, increasing middle ear impedance and attenuating the intensity of sound energy reaching the inner ear (cochlea). The tensor tympani is believed to contract in response to self-generated noise (chewing, swallowing) and nonauditory stimuli. The MEM reflex pathways begin with sound presented to the ear. Transduction of sound occurs in the cochlea, resulting in an action potential that is transmitted along the auditory nerve to the cochlear nucleus in the brainstem (the first relay station for all ascending sound information originating in the ear). Unknown interneurons in the ventral cochlear nucleus project either directly or indirectly to MEM motoneurons located elsewhere in the brainstem. Motoneurons provide efferent innervation to the MEMs. Although the ascending and descending limbs of these reflex pathways have been well characterized, the identity of the reflex interneurons is not known, as are the source of modulatory inputs to these pathways. The aim of this article is to (a) provide an overview of MEM reflex anatomy and physiology, (b) present new data on MEM reflex anatomy and physiology from our laboratory and others, and (c) describe the clinical implications of our research. PMID:20870664

  6. Minnesota wolf ear lengths as possible indicators of taxonomic differences

    USGS Publications Warehouse

    Mech, L. David

    2011-01-01

    Genetic findings suggest that 2 types of wolves, Canis lupus (Gray Wolf) and C. lycaon (Eastern Wolf), and/or their hybrids occupy Minnesota (MN), and this study examines adult wolf ear lengths as a possible distinguisher between these two. Photographic evidence suggested that the Eastern Wolf possesses proportionately longer ears than Gray Wolves. Ear lengths from 22 northwestern MN wolves from the early 1970s and 22 Alaskan wolves were used to represent Gray Wolves, and the greatest length of the sample (12.8 cm) was used as the least length to demarcate Eastern Wolf from Gray Wolf influence in the samples. Twenty-three percent of 112 adult wolves from Algonquin Park in eastern Ontario and 30% of 106 recent adult wolves in northeastern MN possessed ears >12.8 cm. The northeastern MN sample differed significantly from that of current and past northwestern MN wolves. Ear-lengths of wolves in the eastern half of the northeastern MN wolf population were significantly longer than those in the western half of that study area, even though the mean distance between the 2 areas was only 40 km, and the mean length of my 2004–2009 sample was significantly longer than that of 1999–2003. These findings support the hypothesis that Eastern Wolves tend to possess longer ears than do Gray Wolves and suggest a dynamic hybridization process is still underway in MN.

  7. 21 CFR 344.12 - Ear drying aid active ingredient.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 5 2012-04-01 2012-04-01 false Ear drying aid active ingredient. 344.12 Section...) DRUGS FOR HUMAN USE TOPICAL OTIC DRUG PRODUCTS FOR OVER-THE-COUNTER HUMAN USE Active Ingredients § 344.12 Ear drying aid active ingredient. The active ingredient of the product consists of isopropyl...

  8. 21 CFR 344.12 - Ear drying aid active ingredient.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Ear drying aid active ingredient. 344.12 Section...) DRUGS FOR HUMAN USE TOPICAL OTIC DRUG PRODUCTS FOR OVER-THE-COUNTER HUMAN USE Active Ingredients § 344.12 Ear drying aid active ingredient. The active ingredient of the product consists of isopropyl...

  9. 21 CFR 344.12 - Ear drying aid active ingredient.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 5 2013-04-01 2013-04-01 false Ear drying aid active ingredient. 344.12 Section...) DRUGS FOR HUMAN USE TOPICAL OTIC DRUG PRODUCTS FOR OVER-THE-COUNTER HUMAN USE Active Ingredients § 344.12 Ear drying aid active ingredient. The active ingredient of the product consists of isopropyl...

  10. 21 CFR 344.12 - Ear drying aid active ingredient.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Ear drying aid active ingredient. 344.12 Section...) DRUGS FOR HUMAN USE TOPICAL OTIC DRUG PRODUCTS FOR OVER-THE-COUNTER HUMAN USE Active Ingredients § 344.12 Ear drying aid active ingredient. The active ingredient of the product consists of isopropyl...

  11. 21 CFR 344.12 - Ear drying aid active ingredient.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 5 2014-04-01 2014-04-01 false Ear drying aid active ingredient. 344.12 Section...) DRUGS FOR HUMAN USE TOPICAL OTIC DRUG PRODUCTS FOR OVER-THE-COUNTER HUMAN USE Active Ingredients § 344.12 Ear drying aid active ingredient. The active ingredient of the product consists of isopropyl...

  12. [The endoscopic anatomy of the middle ear (a dissection study)].

    PubMed

    Rzaev, R M; Rzaev, R R

    The objective of the present work was to study the specific endoscopic anatomical features of the middle ear using the dissected temporal bones with the intact tympanic membrane. The 18 cm long endoscopes 4 mm in diameter with a visual angle from 0 to 45 degrees in the combination with some other microinstruments, such as ear pincers, needles, curettes, elevators, and suction tubes, were used during the examination. It was shown that endomeato-transtympanic endosopy provides a panoramic view of almost all structures of the middle ear. After the resection of the posterior bone edge of 'annulus tympanicus', the use of the 45o endoscope ensured the panoramic view not only of certain structures of the middle ear (e.g. the tympanic chord, the stapedius muscle tendon, the entire pyramidal process) but also of the structures of the retrotympanic and anterior epitympanic spaces.

  13. A systematic review on external ear melanoma.

    PubMed

    Toia, Francesca; Garbo, Giuseppe; Tripoli, Massimiliano; Rinaldi, Gaetana; Moschella, Francesco; Cordova, Adriana

    2015-07-01

    External ear melanoma accounts for only 1% of all cutaneous melanomas, and data on its optimal management and prognosis are limited. We aim to review the literature on external ear melanoma to guide surgeons in the treatment of this uncommon and peculiar pathology. A systematic review of English language studies on ear melanoma published from 1993 to 2013 was performed using the PubMed electronic database. Data on epidemiology, oncological treatment (tumor resection and regional lymph nodes management), and reconstruction were extrapolated from selected papers. The total number of patients was 858 (30 studies). The helix was the most common location (57%); superficial spreading melanoma was the most common histopathological subtype (41%). The mean Breslow thickness was 2.01 mm, with 88% of stage I-II patients. Sentinel lymph node biopsy was performed in 45% of patients, with 8% of positive nodes. Available data on its prognosis are fragmentary and contrasting, but the Breslow thickness appears to be the main prognostic factor. There is a tendency towards reduced resection margins and preservation of the underlying perichondrium and cartilage. Local flaps are the most popular reconstructive option. To the best of our knowledge, this systematic review presents the largest data series on external ear melanoma. There is no general agreement on its surgical management, but a favorable prognosis seems to justify the tendency towards conservative treatments. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. Shaping sound in space: the regulation of inner ear patterning.

    PubMed

    Groves, Andrew K; Fekete, Donna M

    2012-01-01

    The inner ear is one of the most morphologically elaborate tissues in vertebrates, containing a group of mechanosensitive sensory organs that mediate hearing and balance. These organs are arranged precisely in space and contain intricately patterned sensory epithelia. Here, we review recent studies of inner ear development and patterning which reveal that multiple stages of ear development - ranging from its early induction from the embryonic ectoderm to the establishment of the three cardinal axes and the fine-grained arrangement of sensory cells - are orchestrated by gradients of signaling molecules.

  15. Shaping sound in space: the regulation of inner ear patterning

    PubMed Central

    Groves, Andrew K.; Fekete, Donna M.

    2012-01-01

    The inner ear is one of the most morphologically elaborate tissues in vertebrates, containing a group of mechanosensitive sensory organs that mediate hearing and balance. These organs are arranged precisely in space and contain intricately patterned sensory epithelia. Here, we review recent studies of inner ear development and patterning which reveal that multiple stages of ear development – ranging from its early induction from the embryonic ectoderm to the establishment of the three cardinal axes and the fine-grained arrangement of sensory cells – are orchestrated by gradients of signaling molecules. PMID:22186725

  16. Neonatal Hairy Ear Pinnae and Gestational Diabetes: Just a Coincidence?

    PubMed

    Valerio, Enrico; Riello, Laura; Chirico, Michela; Semenzato, Rossella; Cutrone, Mario

    2015-01-01

    A newborn girl of 36 weeks gestation was noted to have several anomalies, including bilateral low ear attachment with ear pinnae hypertrichosis, left preauricular pit, micrognathia, short lingual frenulum, and short neck. Pregnancy history revealed poorly controlled maternal gestational diabetes (GD). Localized hypertrichosis of the ear pinnae may represent a potential marker of GD and thereby alert physicians to suspect other potentially GD-associated conditions such as macrosomia, asphyxia, respiratory distress, hypoglycemia, hypocalcemia, hyperbilirubinemia, polycythemia, hypertrophic cardiomyopathy, and congenital anomalies, particularly those involving the central nervous system. © 2015 Wiley Periodicals, Inc.

  17. The influence of target-masker similarity on across-ear interference in dichotic listening

    NASA Astrophysics Data System (ADS)

    Brungart, Douglas; Simpson, Brian

    2004-05-01

    In most dichotic listening tasks, the comprehension of a target speech signal presented in one ear is unaffected by the presence of irrelevant speech in the opposite ear. However, recent results have shown that contralaterally presented interfering speech signals do influence performance when a second interfering speech signal is present in the same ear as the target speech. In this experiment, we examined the influence of target-masker similarity on this effect by presenting ipsilateral and contralateral masking phrases spoken by the same talker, a different same-sex talker, or a different-sex talker than the one used to generate the target speech. The results show that contralateral target-masker similarity has the greatest influence on performance when an easily segregated different-sex masker is presented in the target ear, and the least influence when a difficult-to-segregate same-talker masker is presented in the target ear. These results indicate that across-ear interference in dichotic listening is not directly related to the difficulty of the segregation task in the target ear, and suggest that contralateral maskers are least likely to interfere with dichotic speech perception when the same general strategy could be used to segregate the target from the masking voices in the ipsilateral and contralateral ears.

  18. 3D+time acquisitions of 3D cell culture by means of lens-free tomographic microscopy

    NASA Astrophysics Data System (ADS)

    Berdeu, Anthony; Laperrousaz, Bastien; Bordy, Thomas; Morales, S.; Gidrol, Xavier; Picollet-D'hahan, Nathalie; Allier, Cédric

    2018-02-01

    We propose a three-dimensional (3D) imaging platform based on lens-free microscopy to perform multi-angle acquisitions on 3D cell cultures embedded in extracellular matrix (ECM). We developed algorithms based on the Fourier diffraction theorem to perform fully 3D reconstructions of biological samples and we adapted the lens-free microscope to incubator conditions. Here we demonstrate for the first time, 3D+time lens-free acquisitions of 3D cell culture over 8 days directly into the incubator. The 3D reconstructed volume is as large as 5 mm3 and provides a unique way to observe in the same 3D cell culture experiment multiple cell migration strategies. Namely, in a 3D cell culture of prostate epithelial cells embedded within a Matrigel® matrix, we are able to distinguish single cell 'leaders', migration of cell clusters, migration of large aggregates of cells, and also close-gap and large-scale branching. In addition, we observe long-scale 3D deformations of the ECM that modify the geometry of the 3D cell culture. Interestingly, we also observed the opposite, i.e. we found that large aggregates of cells may deform the ECM by generating traction forces over very long distances. In sum we put forward a novel 3D lens-free microscopy tomographic technique to study the single and collective cell migrations, the cell-to-cell interactions and the cell-to-matrix interactions.

  19. Comparison of Inner Ear Contrast Enhancement among Patients with Unilateral Inner Ear Symptoms in MR Images Obtained 10 Minutes and 4 Hours after Gadolinium Injection.

    PubMed

    Kim, T Y; Park, D W; Lee, Y J; Lee, J Y; Lee, S H; Chung, J H; Lee, S

    2015-12-01

    Recently 4-hour delayed-enhanced 3D-FLAIR MR imaging has been used in pathophysiologic analysis of the inner ear in many auditory diseases, including sudden sensorineural hearing loss, but comparison among different time points is not clear in patients with unilateral inner ear symptoms. We compared the signal-intensity ratios of the inner ears in patients with unilateral inner ear symptoms on 10-minute delayed-enhanced and 4-hour delayed-enhanced 3D-FLAIR MR images after IV gadolinium injection. The 10-minute delayed-enhanced and 4-hour delayed-enhanced 3D-FLAIR MR images were retrospectively analyzed. Signal-intensity ratios between the cerebellum and inner ear structures, such as the cochleae, vestibules, and vestibulocochlear nerve were assessed. Multiple comparisons were performed. Signal-intensity ratios of the affected cochleae, vestibules, and vestibulocochlear nerve were higher than those of unaffected sides in both 10-minute delayed-enhanced and 4-hour delayed-enhanced images. At the affected side, signal-intensity ratios of the vestibulocochlear nerve were higher in patients with nonsudden sensorineural hearing loss than in those with sudden sensorineural hearing loss on both 10-minute delayed-enhanced and 4-hour delayed-enhanced images. The signal-intensity ratios of some affected inner ear structures were higher than those of the unaffected sides in a group of 30 patients with sudden sensorineural hearing loss and 20 patients with nonsudden sensorineural hearing loss on 10-minute delayed-enhanced and 4-hour delayed-enhanced images. Signal-intensity ratios of the inner ear show statistically significant increases in many diseases, especially neuritis, in 10-minute delayed-enhanced and 4-hour delayed-enhanced images. The 4-hour delayed-enhanced images may be superior in neural inflammatory-dominant conditions, while 10-minute delayed-enhanced images may be superior in neural noninflammatory-dominant conditions. © 2015 by American Journal of

  20. In vivo over-expression of KGF mimic human middle ear cholesteatoma.

    PubMed

    Yamamoto-Fukuda, Tomomi; Akiyama, Naotaro; Shibata, Yasuaki; Takahashi, Haruo; Ikeda, Tohru; Koji, Takehiko

    2015-10-01

    We reported previously that keratinocyte growth factor (KGF), a mesenchymal cell-derived paracrine growth factor, plays an important role in middle ear cholesteatoma formation, which is characterized by marked proliferation of epithelial cells. Here, we investigated whether KGF, the main factor that induces cholesteatoma, overexpression in vivo results in the formation of cholesteatoma. Flag-hKGF cDNA driven by CMV14 promoter was transfected through electroporation into the external auditory canal (EAC) of rats once (short-term model) or five times on every fourth day (long-term model). Ears transfected with empty vector were used as controls. Successful transfection of plasmids into epithelial and stromal cells was confirmed by Flag immunohistochemistry. In the short-term model, the intensity of KGF protein was the strongest in hKGF transfected ear at day 4. KGF expression induced epithelial cell proliferation, reaching a peak level at day 4 and then decreased later, while in the long-term model, KGF expression in the EAC led to middle ear cholesteatoma formation. In conclusion, we described here a new experimental model of human middle ear cholesteatoma, and demonstrated that KGF and KGF receptor paracrine action play an essential role in middle ear cholesteatoma formation in an in vivo model.

  1. Dysmorphism of the middle ear: case report

    PubMed Central

    Solero, P; Ferrara, M; Musto, R; Pira, A; Di Lisi, D

    2005-01-01

    Summary Although there are numerous publications in the literature describing the wide range of diagnosis, classifications and treatment of malformations of the hearing apparatus, even more variations can be found in clinical practice. Indeed, each individual case is unique as far as concerns pathogenesis, clinical course and treatment. The case reported herein describes a 12-year-old boy affected by cranio-facial dysmorphism and monolateral conductive hearing loss in the right ear: followed from radiological diagnosis – carried out to study a malformation of the ear pinna – to surgical treatment. PMID:16602328

  2. External ear anomalies and hearing impairment in Noonan Syndrome.

    PubMed

    van Trier, Dorothée C; van Nierop, Josephine; Draaisma, Jos M Th; van der Burgt, Ineke; Kunst, Henricus; Croonen, Ellen A; Admiraal, Ronald J C

    2015-06-01

    This is the first cohort in which hearing impairment and external ear anomalies in Noonan Syndrome are described extensively. Retrospective analysis of the otorhinolaryngological and clinical genetic data from 97 Noonan Syndrome (NS) patients. Forty-four NS patients were seen by an otorhinolaryngologist for the analysis of hearing impairment. In our cohort 80 of the 97 patients were genetically tested. In 71 of these mutations were found: in 48 patients a mutation in PTPN11, in 10 patients in SOS1, in 5 patients in SHOC2, in 5 patients in RAF1, in 1 patient in MAP2K2, in 1 patient in KRAS and in 1 patient in A2ML1. External ear anomalies were reported in 75 NS patients (77%). In 69 patients the ears were low-set, 28 patients had posteriorly rotated ears, 14 patients showed protruding ears and 18 had thickened helices. Hearing impairment was detected in 34 NS patients. Nine patients had sensorineural hearing impairment, two a permanent conductive hearing impairment, two other patients had mixed hearing impairment and 20 patients had conductive hearing impairment in the past, caused by otitis media with effusion. Their temporary conductive hearing impairment resolved between the ages of 2 and 18 years. Sensorineural hearing impairment varied between mild high-frequency hearing impairment and profound (uni- and bilateral) hearing impairment and was progressive in three patients. Four NS patients received cochlear implants for their severe sensorineural hearing impairment. The cohort is small for genotype-phenotype correlations, but sensorineural hearing impairment, especially the bilateral severe hearing impairment, was only seen in patients with a PTPN11 mutation. NS is characterized by dysmorphic external ear anomalies and both sensorineural and conductive hearing impairment. Audiological examinations are recommended in all patients with Noonan Syndrome. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. 3D multimodal cardiac data reconstruction using angiography and computerized tomographic angiography registration.

    PubMed

    Moosavi Tayebi, Rohollah; Wirza, Rahmita; Sulaiman, Puteri S B; Dimon, Mohd Zamrin; Khalid, Fatimah; Al-Surmi, Aqeel; Mazaheri, Samaneh

    2015-04-22

    Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography. In this study, coronary arteries from two modalities are registered in order to create a 3D reconstruction of the stenosis position. The proposed method starts with coronary artery segmentation and labeling for both modalities. Then, stenosis and relevant labeled artery in X-ray angiography image are marked by a specialist. Proper control points for the marked artery in both modalities are automatically detected and normalized. Then, a geometrical transformation function is computed using these control points. Finally, this function is utilized to register the marked artery from the X-ray angiography image on the computerized tomographic angiography and get the 3D position of the stenosis lesion. The result is a 3D informative model consisting of stenosis and coronary arteries' information from the X-ray angiography and computerized tomographic angiography modalities. The results of the proposed method for coronary artery segmentation, labeling and 3D reconstruction are evaluated and validated on the dataset containing both modalities. The advantage of this method is to aid specialists to determine a visual relationship between the correspondent coronary arteries from two modalities and also set up a connection between stenosis points from an X-ray angiography along with their 3D positions on the coronary arteries from computerized

  4. Bone Marrow Stem Cells and Ear Framework Reconstruction.

    PubMed

    Karimi, Hamid; Emami, Seyed-Abolhassan; Olad-Gubad, Mohammad-Kazem

    2016-11-01

    Repair of total human ear loss or congenital lack of ears is one of the challenging issues in plastic and reconstructive surgery. The aim of the present study was 3D reconstruction of the human ear with cadaveric ear cartilages seeded with human mesenchymal stem cells. We used cadaveric ear cartilages with preserved perichondrium. The samples were divided into 2 groups: group A (cartilage alone) and group B (cartilage seeded with a mixture of fibrin powder and mesenchymal stem cell [1,000,000 cells/cm] used and implanted in back of 10 athymic rats). After 12 weeks, the cartilages were removed and shape, size, weight, flexibility, and chondrocyte viability were evaluated. P value <0.05 was considered significant. In group A, size and weight of cartilages clearly reduced (P < 0.05) and then shape and flexibility (torsion of cartilages in clockwise and counterclockwise directions) were evaluated, which were found to be significantly reduced (P > 0.05). After staining with hematoxylin and eosin and performing microscopic examination, very few live chondrocytes were found in group A. In group B, size and weight of samples were not changed (P < 0.05); the shape and flexibility of samples were well maintained (P < 0.05) and on performing microscopic examination of cartilage samples, many live chondrocytes were found in cartilage (15-20 chondrocytes in each microscopic field). In samples with human stem cell, all variables (size, shape, weight, and flexibility) were significantly maintained and abundant live chondrocytes were found on performing microscopic examination. This method may be used for reconstruction of full defect of auricles in humans.

  5. Schneiderian-Type Papilloma of the Middle Ear: A Review of the Literature.

    PubMed

    Schaefer, Nathan; Chong, Jessica; Griffin, Aaron; Little, Andrew; Gochee, Peter; Dixon, Natalie

    2015-06-01

    Schneiderian-type papilloma of the middle ear is a rare finding. We present a 46-year-old Aboriginal man with a large tympanic membrane perforation and a Schneiderian-type papilloma filling the middle ear. The aim of this study is to familiarize clinicians with this uncommon disease through discussion of its clinical presentation, diagnostic considerations and management. A search of English-language peer-reviewed literature was undertaken using the key words "Schneiderian-type papilloma," "inverted papilloma," and "middle ear." A total of 29 cases (including the present case) of Schneiderian-type papilloma involving the middle ear were reviewed. Common presenting symptoms include hearing loss, otalgia, and otorrhea. Middle ear disease is associated with higher rates of recurrence and malignant transformation than its sinonasal counterpart. Radical surgical resection is the only curative treatment. Schneiderian-type papilloma is a benign, but locally aggressive, epithelial neoplasm most commonly arising in the sinonasal tract. Whilst involvement of the middle ear is extremely rare, knowledge of this condition is important due to its propensity to recur and the high rate of malignant transformation.

  6. Semiautomated Middle Ear Volume Measurement as a Predictor of Postsurgical Outcomes for Congenital Aural Atresia.

    PubMed

    Kabadi, S J; Ruhl, D S; Mukherjee, S; Kesser, B W

    2018-02-01

    Middle ear space is one of the most important components of the Jahrsdoerfer grading system (J-score), which is used to determine surgical candidacy for congenital aural atresia. The purpose of this study was to introduce a semiautomated method for measuring middle ear volume and determine whether middle ear volume, either alone or in combination with the J-score, can be used to predict early postoperative audiometric outcomes. A retrospective analysis was conducted of 18 patients who underwent an operation for unilateral congenital aural atresia at our institution. Using the Livewire Segmentation tool in the Carestream Vue PACS, we segmented middle ear volumes using a semiautomated method for all atretic and contralateral normal ears on preoperative high-resolution CT imaging. Postsurgical audiometric outcome data were then analyzed in the context of these middle ear volumes. Atretic middle ear volumes were significantly smaller than those in contralateral normal ears ( P < .001). Patients with atretic middle ear volumes of >305 mm 3 had significantly better postoperative pure tone average and speech reception thresholds than those with atretic ears below this threshold volume ( P = .01 and P = .006, respectively). Atretic middle ear volume incorporated into the J-score offered the best association with normal postoperative hearing (speech reception threshold ≤ 30 dB; OR = 37.8, P = .01). Middle ear volume, calculated in a semiautomated fashion, is predictive of postsurgical audiometric outcomes, both independently and in combination with the conventional J-score. © 2018 by American Journal of Neuroradiology.

  7. Closed anterior scoring for prominent-ear correction revisited.

    PubMed

    Thomas, S S; Fatah, F

    2001-10-01

    The closed-anterior-scoring technique has been used over the past 3 years to correct 56 prominent ears in 32 patients at the West Midlands Regional Plastic Surgery Unit at Wordsley Hospital. A review was carried out to assess the result of this surgical procedure. We briefly discuss the historical development of other surgical techniques for prominent-ear correction, and describe in detail the operative technique for this procedure, which includes closed scoring and suturing of the cartilage. We used this technique to treat 24 patients with bilateral prominent ears and eight patients with unilateral prominent ears. The series comprised 20 females and 12 males, 26 children and six adults. The age range was from 4 to 24 years old. There were two complications (an upper-pole recurrence and protrusion of a buried prolene suture). Patients were followed up for between 6 months and 3 years (mean: 1.5 years). This procedure is quick and technically easy to learn, with no anterior scars or posterior cartilage overlap. Minimal dissection is involved, leading to a low rate of complications. The learning curve is rapid; this paper represents the experience of a specialist trainee (SST) after he was taught the technique by the senior author. Copyright 2001 The British Association of Plastic Surgeons.

  8. Sensory Cells of the Fish Ear: A Hairy Enigma

    NASA Technical Reports Server (NTRS)

    Popper, A. N.; Saidel, W. M.

    1995-01-01

    Analysis of the structure of the ears in teleost fishes has led to the tentative suggestion that otolithic endorgans may function differently, in different species. Recently, evidence has demonstrated different 'types' of sensory hair cells can be found in the ears of teleost fishes, and individual hair cell types are found in discrete regions of individual sensory, epithelia. The presence of multiple hair cell types in fishes provides strong support to the hypothesis of regional differences in the responses of individual otolithic sensory epithelia. The finding of hair cell types in fishes that closely resemble those found in amniote vestibular endorgans also suggests that hair cell heterogeneity arose earlier in the evolution of the vertebrate ear than previously thought.

  9. Bacterial invasion of the inner ear in association with pneumococcal meningitis.

    PubMed

    Møller, Martin Nue; Brandt, Christian; Østergaard, Christian; Caye-Thomasen, Per

    2014-06-01

    To examine the pathways of bacterial invasion and subsequent spreading in the inner ear during pneumococcal meningitis. A well-established adult rat model of Streptococcus pneumoniae meningitis was used. Thirty rats were inoculated intrathecally with S. pneumoniae serotype 1, 3 or 9 V and received no additional treatment. The rats were sacrificed when reaching terminal illness or on Day 7 and then prepared for serial sectioning and PAS-Alcian blue staining for light microscopy. During the first few days after inoculation, bacteria invade the inner ear through the cochlear aqueduct, into the scala tympani of the cochlea (perilymphatic space). From here, bacteria spreads apically toward the helicotrema and subsequently basally through the scala vestibuli, toward the vestibule and the vestibular system. When the bacteria after 5 to 6 days had reached scala vestibuli of the basal turn of the cochlea, hematogenous spreading occurred to the spiral ligament and into the cochlear endolymph, subsequently to the vestibular endolymph. We found no evidence of alternative routes for bacterial invasion in the inner ear. Several internal barriers to bacterial spreading were found within the inner ear. Bacterial elimination was evidenced by engulfment by macrophages within the inner ear. From the meninges, pneumococci invade the inner ear through the cochlear aqueduct during the first days of infection, whereas hematogenous invasion via the spiral ligament capillary bed occur at later stages. Although internal barriers exist within the inner ear, the spreading of bacteria occurs via the natural pathways of the fluid compartments. Bacterial elimination occurs by local macrophage engulfment.

  10. Rapid tomographic reconstruction based on machine learning for time-resolved combustion diagnostics

    NASA Astrophysics Data System (ADS)

    Yu, Tao; Cai, Weiwei; Liu, Yingzheng

    2018-04-01

    Optical tomography has attracted surged research efforts recently due to the progress in both the imaging concepts and the sensor and laser technologies. The high spatial and temporal resolutions achievable by these methods provide unprecedented opportunity for diagnosis of complicated turbulent combustion. However, due to the high data throughput and the inefficiency of the prevailing iterative methods, the tomographic reconstructions which are typically conducted off-line are computationally formidable. In this work, we propose an efficient inversion method based on a machine learning algorithm, which can extract useful information from the previous reconstructions and build efficient neural networks to serve as a surrogate model to rapidly predict the reconstructions. Extreme learning machine is cited here as an example for demonstrative purpose simply due to its ease of implementation, fast learning speed, and good generalization performance. Extensive numerical studies were performed, and the results show that the new method can dramatically reduce the computational time compared with the classical iterative methods. This technique is expected to be an alternative to existing methods when sufficient training data are available. Although this work is discussed under the context of tomographic absorption spectroscopy, we expect it to be useful also to other high speed tomographic modalities such as volumetric laser-induced fluorescence and tomographic laser-induced incandescence which have been demonstrated for combustion diagnostics.

  11. Rapid tomographic reconstruction based on machine learning for time-resolved combustion diagnostics.

    PubMed

    Yu, Tao; Cai, Weiwei; Liu, Yingzheng

    2018-04-01

    Optical tomography has attracted surged research efforts recently due to the progress in both the imaging concepts and the sensor and laser technologies. The high spatial and temporal resolutions achievable by these methods provide unprecedented opportunity for diagnosis of complicated turbulent combustion. However, due to the high data throughput and the inefficiency of the prevailing iterative methods, the tomographic reconstructions which are typically conducted off-line are computationally formidable. In this work, we propose an efficient inversion method based on a machine learning algorithm, which can extract useful information from the previous reconstructions and build efficient neural networks to serve as a surrogate model to rapidly predict the reconstructions. Extreme learning machine is cited here as an example for demonstrative purpose simply due to its ease of implementation, fast learning speed, and good generalization performance. Extensive numerical studies were performed, and the results show that the new method can dramatically reduce the computational time compared with the classical iterative methods. This technique is expected to be an alternative to existing methods when sufficient training data are available. Although this work is discussed under the context of tomographic absorption spectroscopy, we expect it to be useful also to other high speed tomographic modalities such as volumetric laser-induced fluorescence and tomographic laser-induced incandescence which have been demonstrated for combustion diagnostics.

  12. Association Between Hearing Loss And Cauliflower Ear in Wrestlers, a Case Control Study Employing Hearing Tests.

    PubMed

    Noormohammadpour, Pardis; Rostami, Mohsen; Nourian, Ruhollah; Mansournia, Mohammad Ali; Sarough Farahani, Saeed; Farahbakhsh, Farzin; Kordi, Ramin

    2015-06-01

    According to anecdotal findings, some wrestling coaches and wrestlers believe that cauliflower ear might lead to hearing loss. Our preliminary study showed that the prevalence of hearing loss reported by the wrestlers with cauliflower ear is significantly higher than this rate among wrestlers without cauliflower ear. To the best of our knowledge, no other study has confirmed this finding employing hearing tests. To evaluate and to compare the prevalence of hearing loss among wrestlers with and without cauliflower ears employing hearing tests. The subjects were randomly selected form 14 wrestling clubs in Tehran. Subjects were 201 wrestlers with cauliflower ears (100 wrestlers with one cauliflower ear and 101 wrestlers with two cauliflower ears) and 139 wrestlers without cauliflower ears. All the participants in this study were interviewed to collect information on demographic factors and medical history of risk factors and diseases related to hearing loss. The subjects in both groups underwent otoscopic and audiologic examinations. Audiometric examination results at the frequency range of 0.5 - 8 KHz showed that the prevalence of hearing loss among cauliflower ears was higher than this rate among non-cauliflower ears. Also, the percentage of positive history of ear infections among cauliflower ears (8.4%) was about two times more than this finding among non-cauliflower ears (4.9%). This difference tended to be significant (OR: 1.86, P = 0.06, 95% CI: 0.98 - 3.53). To the best of our knowledge, this is the first study showing that the prevalence of hearing loss among cauliflower ears is higher than this rate among non-cauliflower ears confirmed by audiological tests. This emphasizes that, more preventive measures such as mandatory ear gear for wrestlers are required.

  13. Association Between Hearing Loss And Cauliflower Ear in Wrestlers, a Case Control Study Employing Hearing Tests

    PubMed Central

    Noormohammadpour, Pardis; Rostami, Mohsen; Nourian, Ruhollah; Mansournia, Mohammad Ali; Sarough Farahani, Saeed; Farahbakhsh, Farzin; Kordi, Ramin

    2015-01-01

    Background: According to anecdotal findings, some wrestling coaches and wrestlers believe that cauliflower ear might lead to hearing loss. Our preliminary study showed that the prevalence of hearing loss reported by the wrestlers with cauliflower ear is significantly higher than this rate among wrestlers without cauliflower ear. To the best of our knowledge, no other study has confirmed this finding employing hearing tests. Objectives: To evaluate and to compare the prevalence of hearing loss among wrestlers with and without cauliflower ears employing hearing tests. Patients and Methods: The subjects were randomly selected form 14 wrestling clubs in Tehran. Subjects were 201 wrestlers with cauliflower ears (100 wrestlers with one cauliflower ear and 101 wrestlers with two cauliflower ears) and 139 wrestlers without cauliflower ears. All the participants in this study were interviewed to collect information on demographic factors and medical history of risk factors and diseases related to hearing loss. The subjects in both groups underwent otoscopic and audiologic examinations. Results: Audiometric examination results at the frequency range of 0.5 - 8 KHz showed that the prevalence of hearing loss among cauliflower ears was higher than this rate among non-cauliflower ears. Also, the percentage of positive history of ear infections among cauliflower ears (8.4%) was about two times more than this finding among non-cauliflower ears (4.9%). This difference tended to be significant (OR: 1.86, P = 0.06, 95% CI: 0.98 - 3.53). Conclusions: To the best of our knowledge, this is the first study showing that the prevalence of hearing loss among cauliflower ears is higher than this rate among non-cauliflower ears confirmed by audiological tests. This emphasizes that, more preventive measures such as mandatory ear gear for wrestlers are required. PMID:26448842

  14. [Impedance characteristics of ear acupoints in identifying excess or deficiency syndrome of stroke].

    PubMed

    Wang, Pin; Yang, Hua-Yuan; Wang, Yi-Qin

    2010-06-01

    To explore the impedance characteristics of ear acupoints in stroke patients with excess or deficiency syndrome, and to provide basis data for objective study of the syndromes of stroke. The data of electrical characteristics of ear acupoints in stroke patients and healthy people were collected, and excess syndrome and deficiency syndrome of stroke were identified by quantifying the syndromes of stroke using scales. The differences in impedance characteristics of ear acupoints between stroke patients and healthy people were analyzed, and the differences in impedance characteristics of ear acupoints between stroke patients with excess syndrome and stroke patients with deficiency syndrome were analyzed too. The correlation among impedance characteristics of ear acupoints, stroke and the syndromes was also analyzed. There were significant differences in impedance characteristics of ear acupoints between stroke patients and healthy people (P<0.05,P<0.01). The ear acupoints CO12 (Gan) and CO13 (Pi) had a significant role in diagnosing stroke as compared with CO18 (Neifenmi), AT3.4.AH12i (Naogan), CO10 (Shen), TG2p (Shenshangxian), AH6a (Jiaogan), AT4 (Pizhixia), and CO15 (Xin). There were significant differences in impedance characteristics of ear acupoints between stroke patients with excess syndrome and stroke patients with deficiency syndrome (P<0.05, P<0.01). The ear acupoints AH6a (Jiaogan) and CO10 (Shen) played an important role in differentiation diagnosis of excess syndrome and deficiency syndrome of stroke, followed by CO18 (Neifenmi), TF4 (Shenmen) and TG2p (Shenshangxian). Some ear acupoints with diagnostic value for stroke may provide basis of objective research for stroke diagnosis as well as identifying excess syndrome and deficiency syndrome of stroke.

  15. Customized acoustic transform functions and their accuracy at predicting real-ear hearing aid performance.

    PubMed

    Munro, K J; Hatton, N

    2000-02-01

    The purpose of the study was to evaluate the validity of predicting the real-ear aided response by adding customized acoustic transform functions to the performance of a hearing aid in a 2-cc coupler. The real-ear hearing aid response, the real-ear-to-coupler difference (RECD/HA2), and field to behind-the-ear microphone transfer functions were measured in both ears of 24 normally hearing subjects using probe-tube microphone equipment. The RECD/HA2 transform function was obtained using both insert earphones and with the hearing aid/ pressure comparison method. An RECD/HA2 transfer function was also obtained with a customized earmold, ER-3A foam tip, and an oto-admittance tip. Validity estimates were calculated as the difference between the derived and measured real-ear response. The derived response was generally within 5 dB of the measured real-ear response when it incorporated an RECD/HA2 transform function obtained with a customized earmold for the specific ear in question. Discrepancies increased when the RECD/HA2 transfer function was obtained from the same subject but the opposite ear. There were significant differences between the RECD/HA2 transform function obtained with customized and temporary earmolds. As a result, the derived response incorporating these transforms differed significantly from the measured real-ear response obtained with the customized earmold. The insert earphone and the hearing aid RECD/HA2 transfer function were equally valid. The derived response may be used as a substitute for in situ hearing aid response procedures when it incorporates acoustic transform functions obtained with a customized earmold from the specific ear in question.

  16. Optimization of tomographic reconstruction workflows on geographically distributed resources

    DOE PAGES

    Bicer, Tekin; Gursoy, Doga; Kettimuthu, Rajkumar; ...

    2016-01-01

    New technological advancements in synchrotron light sources enable data acquisitions at unprecedented levels. This emergent trend affects not only the size of the generated data but also the need for larger computational resources. Although beamline scientists and users have access to local computational resources, these are typically limited and can result in extended execution times. Applications that are based on iterative processing as in tomographic reconstruction methods require high-performance compute clusters for timely analysis of data. Here, time-sensitive analysis and processing of Advanced Photon Source data on geographically distributed resources are focused on. Two main challenges are considered: (i) modelingmore » of the performance of tomographic reconstruction workflows and (ii) transparent execution of these workflows on distributed resources. For the former, three main stages are considered: (i) data transfer between storage and computational resources, (i) wait/queue time of reconstruction jobs at compute resources, and (iii) computation of reconstruction tasks. These performance models allow evaluation and estimation of the execution time of any given iterative tomographic reconstruction workflow that runs on geographically distributed resources. For the latter challenge, a workflow management system is built, which can automate the execution of workflows and minimize the user interaction with the underlying infrastructure. The system utilizes Globus to perform secure and efficient data transfer operations. The proposed models and the workflow management system are evaluated by using three high-performance computing and two storage resources, all of which are geographically distributed. Workflows were created with different computational requirements using two compute-intensive tomographic reconstruction algorithms. Experimental evaluation shows that the proposed models and system can be used for selecting the optimum resources, which in

  17. Optimization of tomographic reconstruction workflows on geographically distributed resources

    PubMed Central

    Bicer, Tekin; Gürsoy, Doǧa; Kettimuthu, Rajkumar; De Carlo, Francesco; Foster, Ian T.

    2016-01-01

    New technological advancements in synchrotron light sources enable data acquisitions at unprecedented levels. This emergent trend affects not only the size of the generated data but also the need for larger computational resources. Although beamline scientists and users have access to local computational resources, these are typically limited and can result in extended execution times. Applications that are based on iterative processing as in tomographic reconstruction methods require high-performance compute clusters for timely analysis of data. Here, time-sensitive analysis and processing of Advanced Photon Source data on geographically distributed resources are focused on. Two main challenges are considered: (i) modeling of the performance of tomographic reconstruction workflows and (ii) transparent execution of these workflows on distributed resources. For the former, three main stages are considered: (i) data transfer between storage and computational resources, (i) wait/queue time of reconstruction jobs at compute resources, and (iii) computation of reconstruction tasks. These performance models allow evaluation and estimation of the execution time of any given iterative tomographic reconstruction workflow that runs on geographically distributed resources. For the latter challenge, a workflow management system is built, which can automate the execution of workflows and minimize the user interaction with the underlying infrastructure. The system utilizes Globus to perform secure and efficient data transfer operations. The proposed models and the workflow management system are evaluated by using three high-performance computing and two storage resources, all of which are geographically distributed. Workflows were created with different computational requirements using two compute-intensive tomographic reconstruction algorithms. Experimental evaluation shows that the proposed models and system can be used for selecting the optimum resources, which in turn can

  18. Optimization of tomographic reconstruction workflows on geographically distributed resources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bicer, Tekin; Gursoy, Doga; Kettimuthu, Rajkumar

    New technological advancements in synchrotron light sources enable data acquisitions at unprecedented levels. This emergent trend affects not only the size of the generated data but also the need for larger computational resources. Although beamline scientists and users have access to local computational resources, these are typically limited and can result in extended execution times. Applications that are based on iterative processing as in tomographic reconstruction methods require high-performance compute clusters for timely analysis of data. Here, time-sensitive analysis and processing of Advanced Photon Source data on geographically distributed resources are focused on. Two main challenges are considered: (i) modelingmore » of the performance of tomographic reconstruction workflows and (ii) transparent execution of these workflows on distributed resources. For the former, three main stages are considered: (i) data transfer between storage and computational resources, (i) wait/queue time of reconstruction jobs at compute resources, and (iii) computation of reconstruction tasks. These performance models allow evaluation and estimation of the execution time of any given iterative tomographic reconstruction workflow that runs on geographically distributed resources. For the latter challenge, a workflow management system is built, which can automate the execution of workflows and minimize the user interaction with the underlying infrastructure. The system utilizes Globus to perform secure and efficient data transfer operations. The proposed models and the workflow management system are evaluated by using three high-performance computing and two storage resources, all of which are geographically distributed. Workflows were created with different computational requirements using two compute-intensive tomographic reconstruction algorithms. Experimental evaluation shows that the proposed models and system can be used for selecting the optimum resources, which in

  19. Online 3D Ear Recognition by Combining Global and Local Features.

    PubMed

    Liu, Yahui; Zhang, Bob; Lu, Guangming; Zhang, David

    2016-01-01

    The three-dimensional shape of the ear has been proven to be a stable candidate for biometric authentication because of its desirable properties such as universality, uniqueness, and permanence. In this paper, a special laser scanner designed for online three-dimensional ear acquisition was described. Based on the dataset collected by our scanner, two novel feature classes were defined from a three-dimensional ear image: the global feature class (empty centers and angles) and local feature class (points, lines, and areas). These features are extracted and combined in an optimal way for three-dimensional ear recognition. Using a large dataset consisting of 2,000 samples, the experimental results illustrate the effectiveness of fusing global and local features, obtaining an equal error rate of 2.2%.

  20. Online 3D Ear Recognition by Combining Global and Local Features

    PubMed Central

    Liu, Yahui; Zhang, Bob; Lu, Guangming; Zhang, David

    2016-01-01

    The three-dimensional shape of the ear has been proven to be a stable candidate for biometric authentication because of its desirable properties such as universality, uniqueness, and permanence. In this paper, a special laser scanner designed for online three-dimensional ear acquisition was described. Based on the dataset collected by our scanner, two novel feature classes were defined from a three-dimensional ear image: the global feature class (empty centers and angles) and local feature class (points, lines, and areas). These features are extracted and combined in an optimal way for three-dimensional ear recognition. Using a large dataset consisting of 2,000 samples, the experimental results illustrate the effectiveness of fusing global and local features, obtaining an equal error rate of 2.2%. PMID:27935955