DOT National Transportation Integrated Search
1973-12-01
Twenty-one brands of ear protectors, including custom-molded, wearer-molded, and pre-molded types, were evaluated according to American-standard procedures. Earplugs are described and are listed in the order of their low-frequency (below 1000 Hz) att...
Murphy, William J.; Fackler, Cameron J.; Berger, Elliott H.; Shaw, Peter B.; Stergar, Mike
2015-01-01
Impulse peak insertion loss (IPIL) was studied with two acoustic test fixtures and four hearing protector conditions at the E-A-RCAL Laboratory. IPIL is the difference between the maximum estimated pressure for the open-ear condition and the maximum pressure measured when a hearing protector is placed on an acoustic test fixture (ATF). Two models of an ATF manufactured by the French-German Research Institute of Saint-Louis (ISL) were evaluated with high-level acoustic impulses created by an acoustic shock tube at levels of 134 decibels (dB), 150 dB, and 168 dB. The fixtures were identical except that the E-A-RCAL ISL fixture had ear canals that were 3 mm longer than the National Institute for Occupational Safety and Health (NIOSH) ISL fixture. Four hearing protection conditions were tested: Combat Arms earplug with the valve open, ETYPlugs® earplug, TacticalPro headset, and a dual-protector ETYPlugs earplug with TacticalPro earmuff. The IPILs measured for the E-A-RCAL fixture were 1.4 dB greater than the National Institute for Occupational Safety and Health (NIOSH) ISL ATF. For the E-A-RCAL ISL ATF, the left ear IPIL was 2.0 dB greater than the right ear IPIL. For the NIOSH ATF, the right ear IPIL was 0.3 dB greater than the left ear IPIL. PMID:26356380
Comparison of muzzle suppression and ear-level hearing protection in firearm use.
Branch, Matthew Parker
2011-06-01
To compare noise reduction of commercially available ear-level hearing protection (muffs/inserts) to that of firearm muzzle suppressors. Experimental sound measurements under consistent environmental conditions. None. Muzzle suppressors for 2 pistol and 2 rifle calibers were tested using the Bruel & Kjaer 2209 sound meter and Bruel & Kjaer 4136 microphone calibrated with the Bruel & Kjaer Pistonphone using Military-Standard 1474D placement protocol. Five shots were recorded unsuppressed and 10 shots suppressed under consistent environmental conditions. Sound reduction was then compared with the real-world noise reduction rate of the best available ear-level protectors. All suppressors offered significantly greater noise reduction than ear-level protection, usually greater than 50% better. Noise reduction of all ear-level protectors is unable to reduce the impulse pressure below 140 dB for certain common firearms, an international standard for prevention of sensorineural hearing loss. Modern muzzle-level suppression is vastly superior to ear-level protection and the only available form of suppression capable of making certain sporting arms safe for hearing. The inadequacy of standard hearing protectors with certain common firearms is not recognized by most hearing professionals or their patients and should affect the way hearing professionals counsel patients and the public.
Gender differences in real-world hearing protector attenuation.
Abel, S M; Alberti, P W; Rokas, D
1988-04-01
This research investigated the possibility of differences in real-world attenuation attributable to gender. A total of 160 subjects, 80 males and 80 females, under the age of 45 years, and with normal hearing, were tested. Subjects were assigned to four hearing protector categories with the restriction that there were 20 males and 20 females in each group. The devices chosen for study were the E-A-R expandable foam plug, the Willson Sound Silencer premolded vinyl plug with double flange, the Bilsom Soft polyethylene encapsulated glass fiber plug, and the MSA Ear Defender (V-51R) premolded vinyl plug with single flange. Binaural headphone detection thresholds were measured in quiet with the open ear, and subsequently with protectors fitted binaurally for one-third octave noise bands centered at 250, 500, 1000, 3150 and 6300 Hz. The results indicated that attenuation scores achieved by females were less than those observed for males when the device was sold in only one size. Apart from the question of adequate sizing, for two of the insert protectors studied, mean achieved attenuation fell short of the manufacturer's specifications by as much as 18 dB, for particular frequencies tested. The relatively wide variation in scores observed for all four protectors in spite of experimenter-fit could not be accounted for by differences in either hearing threshold across subjects or by size of plug fit, for those devices available in several sizes.
Pop-rock musicians: assessment of their satisfaction provided by hearing protectors.
Santoni, Cristiane Bolzachini; Fiorini, Ana Claudia
2010-01-01
Pop-rock musicians are at risk of developing hearing loss and other symptoms related to amplified music. The aim of the present study was to assess the satisfaction provided by the use of hearing protection in pop-rock musicians. Contemporary cohort study. A study of 23 male pop-rock musicians, aged between 25 to 45 years. After audiological evaluation (pure tone audiometry, middle ear analysis, TEOAE and DPOAE) hearing protective devices were provided to be used for three months. After that musicians answered a satisfaction assessment questionnaire. The prevalence of hearing loss was of 21.7%. The most common complaints about the hearing protectors were: autophonia, pressure in the ears, interference in high frequencies perception and full time use of the hearing protector during concerts. There was a positive correlation between a reduction in tinnitus after the use of the HPD with the following complaints: tinnitus after beginning the career (p= 0.044), discomfort with the sound intensity in the work place (p= 0.009) and intolerance to loud sound (p= 0.029). There was a high prevalence of hearing loss and a positive tendency towards the use of the ear protector device among the sample population.
[Polymeric hearing protectors in sport shooting].
Lwow, Felicja; Szmigiero, Leszek
2007-01-01
Using hearing protectors during exposition to noise is fundamental to hearing loss prevention. The optimal choice of hearing protectors should take into consideration not only the physical characteristics of the acoustic environment which imply the traumatic action of noise, but also some individual preferences of the user. All contemporary produced hearing protectors both earmuffs as well as earplugs are made of synthetic polymers e.g. ABS, polyvinylchloride, polyethylene, polyurethathane, silicone rubbers. The type of the material used determines hardness, incompressibility and plasticity of the hear protector and may cause some discomfort. A special group of individuals exposed to noise are sport shooters in which (whose) case the exposition to impact noise is several times higher above standards. The aim of this work was an appraisal of the individual preferences in the choice of hearing protectors. The properties of polymers used for the production of hearing protectors were also taken into consideration. 104 females and 93 males representing master class were interviewed in this study. The analysis of the answers indicated that abandoning of hearing protectors by some shooters is due to the frequent skin irritations, overheating in the ear canal and allergy. Shooters linked these problems with the materials used for the production of hearing protectors. Earplugs were preferred by females, whereas males indicated earmuffs as their preferred choice. Females preferred earplugs made of soft materials which can be easily fitted to ear canal. Those males who used earplugs preferred protectors made of hard plastics as they thought this make better insulation. It can be concluded that the choice of the hearing protectors should not be done on the basis acoustic signal characteristics only, but also should reduce some discomforts resulting from properties of the materials used for their production.
Protection Against Hearing Loss in General Aviation Operations, Phase II
NASA Technical Reports Server (NTRS)
Parker, J. F., Jr.
1972-01-01
An inflight evaluation of four aural protectors is presented. The hearing protection devices studied were ear muffs, plastic ear plugs, rubber ear plugs, and wax ear plugs. It is concluded that ear plugs are satisfactory for providing adequate sound attenuation in general aviation aircraft. However, two problems were found in the use of ear plugs; comfort and interference with cabin communications.
40 CFR 211.206-1 - Real ear method.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Real ear method. 211.206-1 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.206-1 Real ear method. (a) The value of sound... “Method for the Measurement of Real-Ear Protection of Hearing Protectors and Physical Attenuation of...
40 CFR 211.206-1 - Real ear method.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Real ear method. 211.206-1 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.206-1 Real ear method. (a) The value of sound... “Method for the Measurement of Real-Ear Protection of Hearing Protectors and Physical Attenuation of...
40 CFR 211.206-1 - Real ear method.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Real ear method. 211.206-1 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.206-1 Real ear method. (a) The value of sound... “Method for the Measurement of Real-Ear Protection of Hearing Protectors and Physical Attenuation of...
40 CFR 211.206-1 - Real ear method.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Real ear method. 211.206-1 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.206-1 Real ear method. (a) The value of sound... “Method for the Measurement of Real-Ear Protection of Hearing Protectors and Physical Attenuation of...
40 CFR 211.206-1 - Real ear method.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Real ear method. 211.206-1 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.206-1 Real ear method. (a) The value of sound... “Method for the Measurement of Real-Ear Protection of Hearing Protectors and Physical Attenuation of...
Biomedical Simulation Models of Human Auditory Processes
NASA Technical Reports Server (NTRS)
Bicak, Mehmet M. A.
2012-01-01
Detailed acoustic engineering models that explore noise propagation mechanisms associated with noise attenuation and transmission paths created when using hearing protectors such as earplugs and headsets in high noise environments. Biomedical finite element (FE) models are developed based on volume Computed Tomography scan data which provides explicit external ear, ear canal, middle ear ossicular bones and cochlea geometry. Results from these studies have enabled a greater understanding of hearing protector to flesh dynamics as well as prioritizing noise propagation mechanisms. Prioritization of noise mechanisms can form an essential framework for exploration of new design principles and methods in both earplug and earcup applications. These models are currently being used in development of a novel hearing protection evaluation system that can provide experimentally correlated psychoacoustic noise attenuation. Moreover, these FE models can be used to simulate the effects of blast related impulse noise on human auditory mechanisms and brain tissue.
40 CFR 211.204-4 - Supporting information.
Code of Federal Regulations, 2010 CFR
2010-07-01
... level as measured at the ear is 92 dBA. 2. The NRR is (value on label) decibels (dB). 3. The level of... must be affixed to the bulk container or dispenser in the same manner as the label, and in a readily... entering a person's ear, when hearing protector is worn as directed, is closely approximated by the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... noise dose. For the purposes of this part, the exchange rate is 5 decibels (5 dB). Hearing protector. Any device or material, capable of being worn on the head or in the ear canal, sold wholly or in part on the basis of its ability to reduce the level of sound entering the ear, and which has a...
Derivation of an analytic expression for the error associated with the noise reduction rating
NASA Astrophysics Data System (ADS)
Murphy, William J.
2005-04-01
Hearing protection devices are assessed using the Real Ear Attenuation at Threshold (REAT) measurement procedure for the purpose of estimating the amount of noise reduction provided when worn by a subject. The rating number provided on the protector label is a function of the mean and standard deviation of the REAT results achieved by the test subjects. If a group of subjects have a large variance, then it follows that the certainty of the rating should be correspondingly lower. No estimate of the error of a protector's rating is given by existing standards or regulations. Propagation of errors was applied to the Noise Reduction Rating to develop an analytic expression for the hearing protector rating error term. Comparison of the analytic expression for the error to the standard deviation estimated from Monte Carlo simulation of subject attenuations yielded a linear relationship across several protector types and assumptions for the variance of the attenuations.
2013-08-01
earplug and earmuff showing HPD simulator elements for energy flow paths...unprotected or protected ear traditionally start with analysis of energy flow through schematic diagrams based on electroacoustic (EA) analogies between...Schröter, 1983; Schröter and Pösselt, 1986; Shaw and Thiessen, 1958, 1962; Zwislocki, 1957). The analysis method tracks energy flow through fluid and
Lee, Kichol; Casali, John G
2017-01-01
To design a test battery and conduct a proof-of-concept experiment of a test method that can be used to measure the detection performance afforded by military advanced hearing protection devices (HPDs) and tactical communication and protective systems (TCAPS). The detection test was conducted with each of the four loudspeakers located at front, right, rear and left of the participant. Participants wore 2 in-ear-type TCAPS, 1 earmuff-type TCAPS, a passive Combat Arms Earplug in its "open" or pass-through setting and an EB-15LE™ electronic earplug. Devices with electronic gain systems were tested under two gain settings: "unity" and "max". Testing without any device (open ear) was conducted as a control. Ten participants with audiometric requirements of 25 dBHL or better at 500, 1000, 2000, 4000, 8000 Hz in both ears. Detection task performance varied with different signals and speaker locations. The test identified performance differences among certain TCAPS and protectors, and the open ear. A computer-controlled detection subtest of the Detection-Recognition/Identification-Localisation-Communication (DRILCOM) test battery was designed and implemented. Tested in a proof-of-concept experiment, it showed statistically-significant sensitivity to device differences in detection effects with the small sample of participants (10). This result has important implications for selection and deployment of TCAPS and HPDs on soldiers and workers in dynamic situations.
Spectral analysis of hearing protector impulsive insertion loss
Fackler, Cameron J.; Berger, Elliott H.; Murphy, William J.; Stergar, Michael E.
2017-01-01
Objective To characterize the performance of hearing protection devices in impulsive-noise conditions and to compare various protection metrics between impulsive and steady-state noise sources with different characteristics. Design Hearing protectors were measured per the impulsive test methods of ANSI/ASA S12.42-2010. Protectors were measured with impulses generated by both an acoustic shock tube and an AR-15 rifle. The measured data were analyzed for impulse peak insertion loss (IPIL) and impulsive spectral insertion loss (ISIL). These impulsive measurements were compared to insertion loss measured with steady-state noise and with real-ear attenuation at threshold (REAT). Study Sample Tested devices included a foam earplug, a level-dependent earplug, and an electronic sound-restoration earmuff. Results IPIL for a given protector varied between measurements with the two impulse noise sources, but ISIL agreed between the two sources. The level-dependent earplug demonstrated level-dependent effects both in IPIL and ISIL. Steady-state insertion loss and REAT measurements tended to provide a conservative estimate of the impulsively-measured attenuation. Conclusions Measurements of IPIL depend strongly on the source used to measure them, especially for hearing protectors with less attenuation at low frequencies. ISIL provides an alternative measurement of impulse protection and appears to be a more complete description of an HPD’s performance. PMID:27885881
"Gun-shooting hearing loss": A pilot study.
Sataloff, Joseph; Hawkshaw, Mary J; Sataloff, Robert T
2010-01-01
Gun-shooting deafness is the common terminology applied to sensorineural hearing loss caused by shooting firearms. Many characteristics of gun-shooting hearing loss have been proposed, but they have not been defined clearly or established conclusively. We studied 37 users of recreational firearms to obtain pilot data to help determine if it is true that right-handed gun shooters develop more hearing loss in the left ear and vice versa, whether everyone who frequently shoots guns develops sensorineural hearing loss, and whether significant hearing loss is typically prevented by wearing commercially available ear protectors while shooting.
Ototraumatic Effects of Hard Rock Music
Reddell, Rayford C.; Lebo, Charles P.
1972-01-01
Temporary and permanent shifts in auditory thresholds were found in 43 hard rock musicians and temporary shifts were also observed in some listeners. The threshold shifts involved all of the conventional puretone test frequencies. Custom-fitted polyvinyl chloride ear protectors were found to be effective in prevention of these noise-induced hearing losses. PMID:5008499
2009-12-01
minimize onset transients. Broadband noise allows the observer access to both binaural cues (interaural differences in time of arrival and intensity) and...in the health sciences. 3’ ed. New York: Wiley; 1983. 18. Carmichel EL, Harris FP, Stoiy BH. Effects of binaural electronic hearing protectors on
Strapazzon, Giacomo; Procter, Emily; Putzer, Gabriel; Avancini, Giovanni; Dal Cappello, Tomas; Überbacher, Norbert; Hofer, Georg; Rainer, Bernhard; Rammlmair, Georg; Brugger, Hermann
2015-11-05
Epitympanic temperature (Tty) measured with thermistor probes correlates with core body temperature (Tcore), but the reliability of measurements at low ambient temperature is unknown. The aim of this study was to determine if commercially-available thermistor-based Tty reflects Tcore in low ambient temperature and if Tty is influenced by insulation of the ear. Thirty-one participants (two females) were exposed to room (23.2 ± 0.4 °C) and low (-18.7 ± 1.0 °C) ambient temperature for 10 min using a randomized cross-over design. Tty was measured using an epitympanic probe (M1024233, GE Healthcare Finland Oy) and oesophageal temperature (Tes) with an oesophageal probe (M1024229, GE Healthcare Finland Oy) inserted into the lower third of the oesophagus. Ten participants wore ear protectors (Arton 2200, Emil Lux GmbH & Co. KG, Wermelskirchen, Switzerland) to insulate the ear from ambient air. During exposure to room temperature, mean Tty increased from 33.4 ± 1.5 to 34.2 ± 0.8 °C without insulation of the ear and from 35.0 ± 0.8 to 35.5 ± 0.7 °C with insulation. During exposure to low ambient temperature, mean Tty decreased from 32.4 ± 1.6 to 28.5 ± 2.0 °C without insulation and from 35.6 ± 0.6 to 35.2 ± 0.9 °C with insulation. The difference between Tty and Tes at low ambient temperature was reduced by 82% (from 7.2 to 1.3 °C) with insulation of the ear. Epitympanic temperature measurements are influenced by ambient temperature and deviate from Tes at room and low ambient temperature. Insulating the ear with ear protectors markedly reduced the difference between Tty and Tes and improved the stability of measurements. The use of models to correct Tty may be possible, but results should be validated in larger studies.
2014-01-01
12 4.2.1 Loudspeaker Array ...Instrumentation 4.2.1 Loudspeaker Array Target stimuli were presented from a spherical loudspeaker array consisting of 57 Meyer Sound MM-4XP miniature... loudspeaker array on a raised platform that placed their ears at the same elevation as the 0° loudspeaker ring. The chair was free to rotate 360° and
Measurement of impulse peak insertion loss for four hearing protection devices in field conditions
Murphy, William J.; Flamme, Gregory A.; Meinke, Deanna K.; Sondergaard, Jacob; Finan, Donald S.; Lankford, James E.; Khan, Amir; Vernon, Julia; Stewart, Michael
2015-01-01
Objective In 2009, the U.S. Environmental Protection Agency (EPA) proposed an impulse noise reduction rating (NRR) for hearing protection devices based upon the impulse peak insertion loss (IPIL) methods in the ANSI S12.42-2010 standard. This study tests the ANSI S12.42 methods with a range of hearing protection devices measured in field conditions. Design The method utilizes an acoustic test fixture and three ranges for impulse levels: 130–134, 148–152, and 166–170 dB peak SPL. For this study, four different models of hearing protectors were tested: Bilsom 707 Impact II electronic earmuff, E·A·R Pod Express, E·A·R Combat Arms version 4, and the Etymotic Research, Inc. Electronic BlastPLG™ EB1. Study sample Five samples of each protector were fitted on the fixture or inserted in the fixture's ear canal five times for each impulse level. Impulses were generated by a 0.223 caliber rifle. Results The average IPILs increased with peak pressure and ranged between 20 and 38 dB. For some protectors, significant differences were observed across protector examples of the same model, and across insertions. Conclusions The EPA's proposed methods provide consistent and reproducible results. The proposed impulse NRR rating should utilize the minimum and maximum protection percentiles as determined by the ANSI S12.42-2010 methods. PMID:22176308
A Guide to the George Palmiter River Restoration Techniques.
1982-03-01
reduction. The raft is driven by a 35 h.p. ’ outboard engine, weighs 4 tons, and has 1500 lb. of flotation material under it. Additionally, the raft has a...Sycamore (Platanus occidentalis) 4. Red Maple (Acer rubrum) 5. Silver Maple (Acer saccharinum) 6. Pin Oak (Quercus palustris) 7. Red Oak (Quercus...safety goggles 5 - ear protectors 5 - flotation jackets 1, - industrial first aid kit--one that floats and is waterproof 1 - snake bite kit several
Spectral analysis of hearing protector impulsive insertion loss.
Fackler, Cameron J; Berger, Elliott H; Murphy, William J; Stergar, Michael E
2017-01-01
To characterise the performance of hearing protection devices (HPDs) in impulsive-noise conditions and to compare various protection metrics between impulsive and steady-state noise sources with different characteristics. HPDs were measured per the impulsive test methods of ANSI/ASA S12.42- 2010 . Protectors were measured with impulses generated by both an acoustic shock tube and an AR-15 rifle. The measured data were analysed for impulse peak insertion loss (IPIL) and impulsive spectral insertion loss (ISIL). These impulsive measurements were compared to insertion loss measured with steady-state noise and with real-ear attenuation at threshold (REAT). Tested HPDs included a foam earplug, a level-dependent earplug and an electronic sound-restoration earmuff. IPIL for a given protector varied between measurements with the two impulse noise sources, but ISIL agreed between the two sources. The level-dependent earplug demonstrated level-dependent effects both in IPIL and ISIL. Steady-state insertion loss and REAT measurements tended to provide a conservative estimate of the impulsively-measured attenuation. Measurements of IPIL depend strongly on the source used to measure them, especially for HPDs with less attenuation at low frequencies. ISIL provides an alternative measurement of impulse protection and appears to be a more complete description of an HPD's performance.
Impulse Noise and Neurosensory Hearing Loss—Relationship to Small Arms Fire
Keim, Robert J.
1970-01-01
The problems of noise are not limited to the simple annoyance of an individual. Noise can produce a permanent hearing handicap. Many everyday activities and hobbies are associated with hazardous exposure to noise. The hunter and the sport shooter are potential subjects of severe and unresolvable hearing loss. Noise-induced hearing loss develops insidiously. The means of prevention are far more simple than is correction of the loss. Wearing ear protectors, plugs or earmuffs, is advisable during exposure to hazardous noise. PMID:5460217
Casali, John G; Robinette, Martin B
2015-02-01
To determine if training with electronically-modulated hearing protection (EMHP) and the open ear results in auditory learning on a horizontal localization task. Baseline localization testing was conducted in three listening conditions (open-ear, in-the-ear (ITE) EMHP, and over-the-ear (OTE) EMHP). Participants then wore either an ITE or OTE EMHP for 12, almost daily, one-hour training sessions. After training was complete, participants again underwent localization testing in all three listening conditions. A computer with a custom software and hardware interface presented localization sounds and collected participant responses. Twelve participants were recruited from the student population at Virginia Tech. Audiometric requirements were 35 dBHL at 500, 1000, and 2000 Hz bilaterally, and 55 dBHL at 4000 Hz in at least one ear. Pre-training localization performance with an ITE or OTE EMHP was worse than open-ear performance. After training with any given listening condition, including open-ear, performance in that listening condition improved, in part from a practice effect. However, post-training localization performance showed near equal performance between the open-ear and training EMHP. Auditory learning occurred for the training EMHP, but not for the non-training EMHP; that is, there was no significant training crossover effect between the ITE and the OTE devices. It is evident from this study that auditory learning (improved horizontal localization performance) occurred with the EMHP for which training was performed. However, performance improvements found with the training EMHP were not realized in the non-training EMHP. Furthermore, localization performance in the open-ear condition also benefitted from training on the task.
Nélisse, Hugues; Gaudreau, Marc-André; Boutin, Jérôme; Voix, Jérémie; Laville, Frédéric
2012-03-01
The effectiveness of hearing protection devices (HPDs), when used in workplace conditions, has been shown over the years to be usually lower than the labeled values obtained under well-controlled laboratory conditions. Causes for such discrepancies have been listed and discussed by many authors. This study is an attempt to understand the issues in greater details and quantify some of these factors by looking at the performance of hearing protectors as a function of time during full work shift conditions. A non-invasive field microphone in the real ear (F-MIRE)-based method has been developed for measuring the effectiveness of different HPDs as a function of time in the workplace. Details of the test procedures, the equipment used, and the post-processing operations are presented and discussed. The methodology was developed in such a way that a complete time and frequency representation are possible. The system was used on a total of 24 workers in eight different companies. Work shifts of up to 9-h long were recorded. Various types of earmuffs and one type of molded earplugs were tested. Attenuation data reported as a function of time showed, for most workers tested, considerable fluctuations over entire work shift periods. Parts of these fluctuations are attributed to variations in the low-frequency content in the noise (in particular for earmuffs) as well as poor insertion and/or fitting of earplugs. Lower performances than laboratory-based ones were once again observed for most cases tested but also, important left and right ear differences were obtained for many individuals. When reported as a function of frequency, the attenuation results suggested that the few approximations used to relate the measurements to subjective real-ear-attenuation-at-threshold (REAT) data were realistic. The use of individualized attenuation data and performance ratings for HPDs as well as a good knowledge of the ambient noise in the workplace are key ingredients when evaluating the performance of hearing protectors in field conditions.
Alali, Khaled; Casali, John G
2012-01-01
The purpose of this study was to assess normal hearing listeners' performance in detecting a stationary backup alarm signal and to quantify the linear distance at detection point. Detection distances for 12 participants with normal hearing were measured while they were fitted with 7 hearing protectors and while they were unoccluded (open ear). A standard (narrowband) backup alarm signal and a broadband (pulsed white noise) backup alarm signal from Brigade[1] were used. The method of limits, with distance as the physical measurement variable and threshold detection as the task, was employed to find at which distance the participant could first detect the backup alarms. A within-subject Analysis of Variance (ANOVA) revealed a significant main effect of the listening conditions on the detection distance in feet. Post hoc analyses indicated that the Bilsom L3HV conventional passive earmuff (at 1132.2 ft detection distance) was significantly poorer compared to all other HPDs and the open ear in detection distance achieved, and that there were no statistically-significant differences between the unoccluded ear (1652.3 ft), EB-15-Lo BlastPLGTM (1546.2 ft), EB-15-Hi BlastPLGTM (1543.4 ft), E-A-R/3M Combat ArmsTM earplug-nonlinear, level-dependent state (1507.8 ft), E-A-R/3M HiFiTM earplug (1497.7 ft), and Bilsom ImpactTM dichotic electronic earmuff (1567.2 ft). In addition, the E-A-R/3M Combat ArmsTM earplug-passive steady state resulted in significantly longer detection distances than only the open ear condition, at 1474.1 ft versus 1652.3 ft for the open ear. ANOVA also revealed a significant main effect of the backup alarm type on detection distance. The means were 1600.9 ft for the standard (narrowband) backup alarm signal, and a significantly closer 1379.4 ft was required for the Brigade broadband backup alarm signal. For on-ground workers, it is crucial to detect backup alarm signals as far away as possible rather than at close distances since this will provide them more time to react to approaching vehicles. The results of this study suggest that as the attenuation of the hearing protectors increases, precautions should be considered by safety professionals. This is because, as it was the case with the Bilsom passive earmuff and E-A-R/3M Combat ArmsTM earplug-passive steady state, high attenuation minimizes the detection distance and as a result on-foot workers will have less time to react to any approaching vehicle. The main effects of the type of backup alarm signal demonstrated a statistically-significant advantage of the standard backup alarm over the broadband backup alarm on detection distance in feet. The magnitude of the improvement produced by the standard backup alarm was 221.5 feet, a very large margin. For example, with a vehicle backing at 10 mph, the 221.5 ft decrease in detection distance with the Brigade alarm equates to the vehicle arriving 15 seconds sooner at the worker from the point at which its alarm was first heard.
The battle against noise in industry
NASA Astrophysics Data System (ADS)
Iudin, E. Ia.
The physiological effects of noise in manufacturing plants and other industrial facilities are discussed, and several common noise abatement methods are described. Consideration is given to the acoustic properties of three types of noise which are present in industrial plants: aerohydrodynamic noise; mechanical noise; and electromagnetic noise. Among the specific noise abatement techniques discussed are: sound isolation by means of noise-absorbant screens; insulation or noise-emitting media; and acoustic interference. The use of earplugs and external ear protectors for protection of individual workers in noisy work environments is also considered.
USAF bioenvironmental noise data handbook. Volume 148. T-37B in-flight crew noise
NASA Astrophysics Data System (ADS)
Hille, H. K.
1981-11-01
The T-37B is a USAF two-seat primary trainer aircraft. This report provides measured data defining the bioacoustic environments at flight crew/passenger locations inside this aircraft during normal flight operations. Data are reported at one location for 19 different flight conditions and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors.
USAF Bioenvironmental Noise Data Handbook. Volume 167: MA-3M air conditioner
NASA Astrophysics Data System (ADS)
Rau, T. H.
1982-06-01
The MA-3M is an electric motor-driven air conditioner designed to cool electronic equipment on aircraft during ground maintenance. This report provides measured and extrapolated data defining the bioacoustic environments produced by this unit operating at a normal rated condition. Near-field data are reported for 37 locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference levels, perceived noise levels, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors.
USAF Bioenvironmental Noise Data Handbook. Volume 149: C-9A in-flight crew/passenger noise
NASA Astrophysics Data System (ADS)
Rau, T. H.
1982-05-01
The C-9A is a McDonnell Douglas DC-9 series 30 commercial transport modified to perform aeromedical evacuation missions. This report provides measured data defining the bioacoustic environments at flight crew/passenger locations inside this aircraft during normal flight operations. Data are reported for 56 locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors.
Gondusky, Joseph S; Reiter, Michael P
2005-06-01
Improvised explosive devices and mines pose a formidable threat to military convoys traveling in Iraq. This study evaluated battle injuries sustained by a mechanized battalion operating against this threat. The objective was to gain insight into injury profiles and prevention. In the period examined, 32 attacks injured 120 Marines, causing 188 injuries. Upper extremity and head injuries (70%) were common, whereas lower extremity injuries (11%) were rare (as expected, given the threat and the body areas exposed). Shoulder and axilla protectors may be beneficial, but lower arm and hand injuries remain difficult to combat. Ear injury was the most common single injury type (23%). Combat earplugs may reduce ear blast injuries. Eye injuries were uncommon (0.5%), likely because of ballistic eye protection. Injury to the torso (11%) was generally mild, because of body armor vests. The majority of wounds were minor, allowing > 80% of the injured Marines to return to duty.
UDAF bioenvironmental noise data handbook. Volume 164: MD-1 heater, duct type, portable
NASA Astrophysics Data System (ADS)
Rau, T. H.
1982-05-01
The MD-1 heater is an electric motor-driven, portable ground heater used primarily for cockpit and cabin temperature control. This report provides measured and extrapolated data defining the bioacoustic environments produced by this unit operating outdoors on a concrete apron at normal rated conditions. Near-field data are reported for 37 locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise levels, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors.
USAF bioenvironmental noise data handbook. Volume 162: MD-4MO generator set
NASA Astrophysics Data System (ADS)
Rau, T. H.
1982-05-01
The MD-4MO generator set is an electric motor-driven source of electrical power used primarily for the starting of aircraft, and for ground maintenance. This report provides measured and extrapolated data defining the bioacoustic environments produced by this unit operating outdoors on a concrete apron at a normal rated condition. Near-field data are reported for 37 locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference levels, perceived noise levels, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors.
NASA Astrophysics Data System (ADS)
Rau, T. H.
1982-06-01
The MB-3 Tester is an electric motor-driven cabin leakage tester designed to furnish pressurized air to the aircraft at controlled pressures and temperatures during ground pressurization of aircraft cockpits and pressurized compartments. This report provides measured data defining the bioacoustic environments produced by this unit operating at a normal rated/load condition. Near-field data are reported for 37 locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors.
Brammer, Anthony J; Yu, Gongqiang; Bernstein, Eric R; Cherniack, Martin G; Peterson, Donald R; Tufts, Jennifer B
2014-08-01
An adaptive, delayless, subband feed-forward control structure is employed to improve the speech signal-to-noise ratio (SNR) in the communication channel of a circumaural headset/hearing protector (HPD) from 90 Hz to 11.3 kHz, and to provide active noise control (ANC) from 50 to 800 Hz to complement the passive attenuation of the HPD. The task involves optimizing the speech SNR for each communication channel subband, subject to limiting the maximum sound level at the ear, maintaining a speech SNR preferred by users, and reducing large inter-band gain differences to improve speech quality. The performance of a proof-of-concept device has been evaluated in a pseudo-diffuse sound field when worn by human subjects under conditions of environmental noise and speech that do not pose a risk to hearing, and by simulation for other conditions. For the environmental noises employed in this study, subband speech SNR control combined with subband ANC produced greater improvement in word scores than subband ANC alone, and improved the consistency of word scores across subjects. The simulation employed a subject-specific linear model, and predicted that word scores are maintained in excess of 90% for sound levels outside the HPD of up to ∼115 dBA.
[Evaluation of the risk on hearing loss at soldiers].
Konopka, Wiesław; Olszewski, Jurek; Straszyński, Piotr
2006-01-01
Noise produced by weapons may be harmful to soldiers during military service. Exposure to impulse noise during compulsory military service depends on the number of shots, explosion impulses, distance of injured ear from causal firearm as well as on the use of hearing protectors. Weapons produce impulse noises, which are characterized by peak pressure level and frequency. The purpose of this work was to calculate and estimate risk on hearing at soldiers during one year of the military service. The study comparised three groups of soldiers with different kind of exposure to noise divided according total noise exposure. In order to evaluate the amount of the exposure to impulse noise the total level of noise and the spectrum analysis were performed for all types of weapons, which were used during military service. The equivalent continuous A-weighted sound pressure level, L A eq, Te [dB], maximum A-weighted sound pressure level, L A max [dB] and C weighted peak sound pressure level, L C peak [dB] were measured. The highest total exposure to noise concerned group I (2222,9 kPa(2)/s for right ear and 22212,8 kPa(2)/s for left one) with total exposure time 248,3 minutes. In the II group estimated total exposure to noise was 611,8 kPa(2)/s for right ear and 743,6 kPa(2)/s for left one. In the III group least exposed to noise, estimated total exposure to noise was 103 kPa(2)/s for right ear and 109 kPa(2)/s for left one with total time exposure 17,8 minutes. Difference between groups is dependent on kind of military service. Estimated exposure to weapons noise may prevent soldiers before hearing loss. We did not notice differences between sites of ears.
NASA Astrophysics Data System (ADS)
Rau, T. H.
1982-07-01
Measured and extrapolated data define the bioacoustic environments produced by a gasoline engine driven cabin leakage tester operating outdoors on a concrete apron at normal rated conditions. Near field data are presented for 37 locations at a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors. Far-field data measured at 36 locations are normalized to standard meteorological conditions and extrapolated from 10 - 1600 meters to derive sets of equal-value contours for these same seven acoustic measures as functions of angle and distance from the source.
Sims-Gould, Joanie; McKay, Heather A.; Feldman, Fabio; Scott, Victoria; Robinovitch, Stephen N.
2013-01-01
The purpose of this study was to examine long-term care (LTC) resident and staff perceptions on the decision to use hip protectors and identify the factors that influence attitudes toward hip protector use. Staff (N = 39) and residents (N = 27) at two residential care facilities in British Columbia, Canada were invited to participate in focus groups on fall prevention and hip protector use. A total of 11 focus groups were conducted. Using framework analysis results show that residents and staff shared concerns on aesthetic and comfort issues with hip protectors. Residents also generally felt they did not need, or want to use, hip protectors. However, they also had desire to be cooperative within the LTC environment. Staff underscored their role in advocating for hip protector use and their desire to protect residents from harm. Practice considerations for facilities wishing to promote hip protectors within a patient centered framework are highlighted. PMID:24652886
21 CFR 868.5820 - Dental protector.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental protector. 868.5820 Section 868.5820 Food... DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5820 Dental protector. (a) Identification. A dental protector is a device intended to protect a patient's teeth during manipulative procedures within...
21 CFR 868.5820 - Dental protector.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental protector. 868.5820 Section 868.5820 Food... DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5820 Dental protector. (a) Identification. A dental protector is a device intended to protect a patient's teeth during manipulative procedures within...
21 CFR 868.5820 - Dental protector.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental protector. 868.5820 Section 868.5820 Food... DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5820 Dental protector. (a) Identification. A dental protector is a device intended to protect a patient's teeth during manipulative procedures within...
21 CFR 868.5820 - Dental protector.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental protector. 868.5820 Section 868.5820 Food... DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5820 Dental protector. (a) Identification. A dental protector is a device intended to protect a patient's teeth during manipulative procedures within...
21 CFR 868.5820 - Dental protector.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental protector. 868.5820 Section 868.5820 Food... DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5820 Dental protector. (a) Identification. A dental protector is a device intended to protect a patient's teeth during manipulative procedures within...
Determinants of staff commitment to hip protectors in long-term care: A cross-sectional survey.
Korall, Alexandra M B; Loughin, Thomas M; Feldman, Fabio; Cameron, Ian D; Leung, Pet Ming; Sims-Gould, Joanie; Godin, Judith; Robinovitch, Stephen N
2018-06-01
If worn, certain models of hip protectors are highly effective at preventing hip fractures from falls in residents of long-term care, but modest acceptance and adherence have limited the effectiveness of hip protectors. Residents of long-term care are more likely to accept the initial offer of hip protectors and to adhere to recommendations concerning the use of hip protectors when staff are committed to supporting the application of hip protectors. Yet, we know very little about the nature of and factors associated with staff commitment to hip protectors in long-term care. To identify factors associated with staff commitment to hip protectors in long-term care. A cross-sectional survey. Thirteen long-term care homes (total beds = 1816) from a single regional health district in British Columbia, Canada. A convenience sample of 535 paid staff who worked most of their time (>50% of work hours) at a participating long-term care home, for at least one month, and for at least 8 h per week. We excluded six (1.1%) respondents who were unaware of hip protectors. Of the remaining 529 respondents, 90% were female and 55% were health care assistants. Respondents completed the Commitment to Hip Protectors Index to indicate their commitment to hip protectors. We used Bayesian Model Averaging logistic regression to model staff commitment as a function of personal variables, experiences with hip protectors, intraorganizational communication and influence, and organizational context. Staff commitment was negatively related to organizational tenure >20 years (posterior probability = 97%; logistic regression coefficient = -0.28; 95% confidence interval = -0.48, -0.08), and awareness of a padded hip fracture (100%; -0.57; -0.69, -0.44). Staff commitment was positively related to the existence of a champion of hip protectors within the home (100%; 0.24; 0.17, 0.31), perceived quality of intraorganizational communication (100%; 0.04; 0.02, 0.05), extent of mutual respect between residents and staff and perceived contribution to quality of life of the residents they serve (100%; 0.10; 0.05, 0.15), and frequency of transformational leadership practices by respondents' primary supervisors (100%; 0.01; 0.01, 0.02). We provide novel insight into the factors governing staff commitment to hip protectors in long-term care. Targeting of these factors could improve acceptance and adherence with hip protectors, thereby contributing to enhanced effectiveness of hip protectors to prevent hip fractures in long-term care. Copyright © 2018. Published by Elsevier Ltd.
21 CFR 880.6450 - Skin pressure protectors.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Skin pressure protectors. 880.6450 Section 880... Devices § 880.6450 Skin pressure protectors. (a) Identification. A skin pressure protector is a device intended for medical purposes that is used to reduce pressure on the skin over a bony prominence to reduce...
21 CFR 880.6450 - Skin pressure protectors.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Skin pressure protectors. 880.6450 Section 880... Devices § 880.6450 Skin pressure protectors. (a) Identification. A skin pressure protector is a device intended for medical purposes that is used to reduce pressure on the skin over a bony prominence to reduce...
21 CFR 880.6450 - Skin pressure protectors.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Skin pressure protectors. 880.6450 Section 880... Devices § 880.6450 Skin pressure protectors. (a) Identification. A skin pressure protector is a device intended for medical purposes that is used to reduce pressure on the skin over a bony prominence to reduce...
21 CFR 880.6450 - Skin pressure protectors.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Skin pressure protectors. 880.6450 Section 880... Devices § 880.6450 Skin pressure protectors. (a) Identification. A skin pressure protector is a device intended for medical purposes that is used to reduce pressure on the skin over a bony prominence to reduce...
21 CFR 880.6450 - Skin pressure protectors.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Skin pressure protectors. 880.6450 Section 880... Devices § 880.6450 Skin pressure protectors. (a) Identification. A skin pressure protector is a device intended for medical purposes that is used to reduce pressure on the skin over a bony prominence to reduce...
Powers, J M; Godwin, W C; Heintz, W D
1984-07-01
A mouth protector must be easy to fabricate, comfortable, able to accommodate the needs of an individual's dentition, durable, easily held in place, and able to provide adequate protection to the teeth, jaws, and cranial structures. The thermoplastic mouth protector is recommended if it is to be placed or formed by the athlete; however, supervision of the fitting procedure by a dentist is recommended. The most desirable protector, however, is the custom-made mouth protector fabricated by a dentist from a thermoplastic material. With the custom-made protector, the dentist can optimize fit, comfort, and speech as well as tend to any control of form to the special dental requirements of the athlete. Thousands of football players have avoided oral injuries by wearing mouth protectors and faceguards. In other sports, dental safety still needs to be improved. National athletic organizations should be urged to require players to wear adequate mouth protectors. Dentists, health and physical education professionals, and other concerned persons should tell all athletes, patients, and parents, why mouth protectors are necessary and what types of protectors effectively reduce or minimize the incidence of injury. All organized sports teams should have their own team dentists to help ensure that players maintain the best possible oral health. If these actions are taken, fewer athletes will suffer the pain, inconvenience, and expense of unnecessary and frequently disfiguring oral injuries.
USAF Bioenvironmental Noise Data Handbook. Volume 155. CH-3 in-flight crew noise
NASA Astrophysics Data System (ADS)
Hille, H. K.
1982-09-01
The CH-3 is a USAF tactical combat transport helicopter. This report provides measured data defining the bioacoustic environments at flight crew/passenger locations inside this helicopter during normal flight operations. Data are reported for nine locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C weighted and A weighted sound levels, preferred speech interference level, perceived noise levels and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors. Refer to Volume 1 of this handbook, USAF Bioenvironmental Noise Data handbook, Vol. 1: Organization, Content and Application, AMRL-TR-75-50(1) 1975, for discussion of the objective and design of the handbook, the types of data presented, measurement procedures, instrumentation, data processing, definitions of quantities, symbols, equations, applications, limitations, etc.
USAF Environmental Noise Data Handbook. Volume 150: C-140 in-flight crew noise
NASA Astrophysics Data System (ADS)
Hille, H. K.
1982-09-01
The C-140 is a USAF transport aircraft used for operational support. This report provides measured data defining the bioacoustic environments at flight crew/passenger locations inside this aircraft during normal flight operations. Date are reported for seven locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors. Refer to Volume 1 of this handbook, USAF Bioenvironmental Noise Data Handbook, Vol. 1: Organization, Content and Application, AMRL-TR-75-50(1) 1975, for discussion of the objective and design of the handbook, the types of data presented, measurement procedures, instrumentation, data processing, definitions of quantities, symbols, equations, applications, limitations, etc.
Aliabadi, Mohsen; Biabani, Azam; Golmohammadi, Rostam; Farhadian, Maryam
2018-05-28
Actual noise reduction of the earmuffs is considered as one of the main challenges for the evaluation of the effectiveness of a hearing conservation program. The current study aimed to determine the real world noise attenuation of current hearing protection devices in typical workplaces using a field microphone in real ear (FMIRE) method. In this cross-sectional study, five common earmuffs were investigated among 50 workers in two industrial factories with different noise characteristics. Noise reduction data was measured with the use of earmuffs based on the ISO 11904 standard, field microphone in real ear method, using noise dosimeter (SVANTEK, model SV 102) equipped with a microphone SV 25 model. The actual insertion losses (IL) of the tested earmuffs in octave band were lower than the labeled insertion loss data (p < 0.05). The frequency nature of noise to which workers are exposed has noticeable effects on the actual noise reduction of earmuffs (p < 0.05). The results suggest that the proportion of time using earmuffs has a considerable impact on the effective noise reduction during the workday. Data about the ambient noise characteristics is a key criterion when evaluating the acoustic performance of hearing protectors in any workplaces. Comfort aspects should be considered as one of the most important criteria for long-term use and effective wearing of hearing protection devices. FMIRE could facilitate rapid and simple measurement of the actual performance of the current earmuffs employed by workers during different work activities.
A systematic review on the effectiveness of back protectors for motorcyclists.
Ekmejian, Rafael; Sarrami, Pooria; Naylor, Justine M; Harris, Ian A
2016-10-04
Motorcyclists are a vulnerable road-user population who are overrepresented in traffic injuries. Utilisation of back protectors may be an effective preventive measure for spine injuries in motorcyclists. Since use of back protectors is increasing it is important that clinical evidence supports their use. The study aimed to investigate the current evidence on the ability of back protectors to reduce the rate of back injuries and patient mortality in motorcycle crashes. A systematic literature search was conducted using various electronic databases. Systematic reviews, randomised controlled trials, controlled clinical trials, cohort studies, case series and case reports were included Opinion pieces and laboratory or biomechanical studies were excluded. Back protectors and spine protectors were included as the intervention; neck braces and speed humps were excluded. The target outcomes were any injuries to the back or death. Only English language studies were included. The search strategy yielded 185 studies. After excluding 183 papers by title and abstract and full-text evaluation, only two small cross-sectional studies were included. Foam inserts in motorcycle jackets and non-standard clothing may possibly be associated with higher risk of injuries, while hard shell and standard back protectors may possibly be associated with a reduced rate of back and spinal injury. This systematic review highlighted lack of appropriate evidence on efficacy of back protectors. Based on limited information, we are uncertain about the effects of back protectors on spinal injuries. Further research is required to substantiate the effects of back protectors on mortality and other injuries to the back.
Social Desirability Bias in Self-Reporting of Hearing Protector Use among Farm Operators
McCullagh, Marjorie C.; Rosemberg, Marie-Anne
2015-01-01
Objective: The purposes of this study were (i) to examine the relationship between reported hearing protector use and social desirability bias, and (ii) to compare results of the Marlowe-Crowne social desirability instrument when administered using two different methods (i.e. online and by telephone). Methods: A shortened version of the Marlowe-Crowne social desirability instrument, as well as a self-administered instrument measuring use of hearing protectors, was administered to 497 participants in a study of hearing protector use. The relationship between hearing protector use and social desirability bias was examined using regression analysis. The results of two methods of administration of the Marlowe-Crowne social desirability instrument were compared using t-tests and regression analysis. Results: Reliability (using Cronbach’s alpha) for the shortened seven-item scale for this sample was 0.58. There was no evidence of a relationship between reported hearing protector use and social desirability reporting bias, as measured by the shortened Marlowe-Crowne. The difference in results by method of administration (i.e. online, telephone) was very small. Conclusions: This is the first published study to measure social desirability bias in reporting of hearing protector use among farmers. Findings of this study do not support the presence of social desirability bias in farmers’ reporting of hearing protector use, lending support for the validity of self-report in hearing protector use in this population. PMID:26209595
Starting a Planet Protectors Club
ERIC Educational Resources Information Center
US Environmental Protection Agency, 2007
2007-01-01
If your mission is to teach children how to reduce, reuse, and recycle waste and create the next generation of Planet Protectors, perhaps leading a Planet Protectors Club is part of your future challenges. You don't have to be an expert in waste reduction and recycling to lead a a Planet Protectors Club. You don't even have to be a teacher. You do…
The Effect of Color on the Use of Electronic Body Protectors in Taekwondo Matches.
Falcó, Coral; Conchado, Andrea; Estevan, Isaac
2016-06-01
This study investigated the relationship between the color protector and success in taekwondo combats in the qualification championships, when electronic body protectors were used. Moreover, it analyzed the confounding effect of a participant being a top-ranked athlete in the 2012 London Olympic Games, in a sample of 462 matches. Results from the entire sample showed a non-significant relationship between the combat outcome and the winner's color electronic protector. At the level of the tournament, the results showed a significant relationship between wearing a red electronic protector and winning the combat in the Asian and the European qualification tournaments. For gender and weight categories, there was no clear color effect. A significant association was, however, found between wearing red and winning the match in the female featherweight category. The inclusion of electronic body protectors and a counterbalanced seed-condition seem to be effective for controlling the effect of the protector's color on the outcomes of combats. © The Author(s) 2016.
Hip protector compliance: a 13-month study on factors and cost in a long-term care facility.
Burl, Jeffrey B; Centola, James; Bonner, Alice; Burque, Colleen
2003-01-01
To determine if a high compliance rate for wearing external hip protectors could be achieved and sustained in a long-term care population. A 13-month prospective study of daytime use of external hip protectors in an at-risk long-term care population. One hundred-bed not-for-profit long-term care facility. Thirty-eight ambulatory residents having at least 1 of 4 risk factors (osteoporosis, recent fall, positive fall screen, previous fracture). The rehabilitation department coordinated an implementation program. Members of the rehabilitation team met with eligible participants, primary caregivers, families, and other support staff for educational instruction and a description of the program. The rehabilitation team assumed overall responsibility for measuring and ordering hip protectors and monitoring compliance. By the end of the third month, hip protector compliance averaged greater than 90% daily wear. The average number of falls per month in the hip protector group was 3.9 versus 1.3 in nonparticipants. Estimated total indirect staff time was 7.75 hours. The total cost of the study (hip protectors and indirect staff time) was 6,300 US dollars. High hip protector compliance is both feasible and sustainable in an at-risk long-term care population. Achieving high compliance requires an interdisciplinary approach with one department acting as a champion. The cost of protectors could be a barrier to widespread use. Facilities might be unable to cover the cost until the product is paid for by third-party payers.
Social environmental factors and preteen health-related behaviors.
Adelmann, Pamela K
2005-01-01
To examine associations among risk and protective factors with negative (substance use, delinquent behavior, sedentary recreation, empty calorie consumption, suicidal behavior) and positive behaviors (prosocial recreation, productive behavior, exercise, nutrition behavior, academic achievement, seatbelt use). Data were from sixth-grade public school students (n = 133,629) in 2001. Factor analysis produced five risks, five protectors, seven negative and six positive behaviors. Associations were tested among single and cumulative risks and protectors with behaviors (linear, logit regression) and combinations of high and low risks and protectors with behaviors (analysis of variance, Chi-square). Individual and cumulative risks were related to higher and protectors were related to lower negative behaviors. Protectors were associated with higher positive behaviors, with some exceptions. Risks and their sum were associated with lower academic achievement and seatbelt use, but were linked to higher, rather than lower productive behavior. Being bullied or victimized was correlated with higher levels of exercise, good nutrition, and prosocial recreation. The high risk/low protection combination had the highest negative behaviors and low risk/high protection the lowest, but for positive behaviors, high protectors with either high or low risks showed higher positive behaviors. These findings provide new information about how (a) risks and protectors are associated with negative behaviors besides substance use and delinquency, (b) cumulative protectors, as well as risks, are related to negative and positive behaviors, and (c) combinations of high and low risks and protectors are related to behaviors. The unusual findings for positive behaviors merit further exploration.
USAF bioenvironmental noise data handbook. Volume 157: KC-10A in-flight crew noise
NASA Astrophysics Data System (ADS)
Hille, H. K.
1982-09-01
The KC-10A is a standard USAF tanker-transport aircraft with high-speed, high altitude refueling and long range transport capability. This report provides measured data defining the bioacoustic environments at flight crew/passenger locations inside this helicopter during normal flight operations. Data are reported for 24 locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors. Refer to Volume 1 of this handbook, USAF Bioenvironmental Noise Data Handbook, Vol. 1: Organization, Content and Application, AMRL-TR-75-50(1) 1975, for discussion of the objective and design of the handbook, the types of data presented, measurement procedures, instrumentation, data processing, definitions of quantities, symbols, equations, applications, limitations, etc.
USAF Bioenvironmental Noise Data Handbook. Volume 165: MC-1 heater, duct type, portable
NASA Astrophysics Data System (ADS)
Rau, T. H.
1982-06-01
The MC-1 heater is a gasoline-motor driven, portable ground heater used primarily for cockpit and cabin temperature control. This report provides measured and extrapolated data defining the bioacoustic environments produced by this unit operating outdoors on a concrete apron at normal rated conditions. Near-field data are reported for 37 locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise levels, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors. Far-field data measured at 36 locations are normalized to standard meteorological conditions and extrapolated from 10 1600 meters to derive sets of equal-value contours for these same seven acoustic measures as functions of angle and distance from the source.
USAF Bioenvironmental Noise Data Handbook. Volume 152: C-12A in-flight crew noise
NASA Astrophysics Data System (ADS)
Hille, H. K.
1982-09-01
The C-12A is a military version of the Beechcraft Super King Air 200. This report provides measured data defining the bioacoustic environments at flight crew/passenger locations inside this aircraft during normal flight operations. Data are reported for five locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors. Refer to Volume 1 of this handbook, USAF Bioenvironmental Noise Data Handbook, Vol 1: Organization, Content and Application, AMRL-TR-75-50(1) 1975, for discussion of the objective and design of the handbook, the types of data presented, measurement procedures, instrumentation, data processing, definitions of quantities, symbols, equations, applications, limitations, etc.
USAF Bioenvironmental Noise Data Handbook. Volume 156. HH-1N In-flight Crew Noise
NASA Astrophysics Data System (ADS)
Hille, H. K.
1982-11-01
The HH-IN is a USAF multi-purpose utility helicopter providing support for various USAF missions. This report provides measured data defining the bioacoustic environments at flight crew locations inside this helicopter during normal flight operations. Data are reported for two locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors. Refer to Volume 1 of this handbook, USAF Bioenvironmental Noise Data Handbook, Vol. 1: Organization, Content and Application, AMRL-TR-75-50(1) 1975, for discussion of the objective and design of the handbook, the types of data presented, measurement procedures, instrumentation, data processing, definitions of quantities, symbols, equations, applications, limitations, etc.
USAF bioenvironmental noise data handbook. Volume 158: F-106A aircraft, near and far-field noise
NASA Astrophysics Data System (ADS)
Rau, T. H.
1982-05-01
The USAF F-106A is a single seat, all-weather fighter/interceptor aircraft powered by a J75-P-17 turbojet engine. This report provides measured and extrapolated data defining the bioacoustic environments produced by this aircraft operating on a concrete runup pad for five engine-power conditions. Near-field data are reported for five locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise levels, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors. Far-field data measured at 19 locations are normalized to standard meteorological conditions and extrapolated from 75 - 8000 meters to derive sets of equal-value contours for these same seven acoustic measures as functions of angle and distance from the source.
USAF Bioenvironmental Noise Data Handbook, volume 154
NASA Astrophysics Data System (ADS)
Rau, T. H.
1982-05-01
The E-4B is a Boeing 747 aircraft modified to serve as the national emergency/HQ Strategic Air Command Airborne Command Post. This report provides measured data defining the bioacoustic environments at flight crew/passenger locations inside this aircraft during normal flight operations. Data are reported for 24 locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors. Refer to Volume 1 of this handbook, "USAF Bioenvironmental Noise Data Handbook, Vol. 1: Organization, Content and Application", AMRL-TR-75-50(1) 1975, for discussion of the objective and design of the handbook, the types of data presented, measurement procedures, instrumentation, data processing, definitions of quantities, symbols, equations, applications, limitations, etc.
USAF bioenvironmental noise data handbook. Volume 163: GPC-28 compressor
NASA Astrophysics Data System (ADS)
Rau, T. H.
1982-05-01
The GPC-28 is a gasoline engine-driven compressor with a 120 volt 60 Hz generator used for general purpose maintenance. This report provides measured and extrapolated data defining the bioacoustic environments produced by this unit operating outdoors on a concrete apron at a normal rated condition. Near-field data are reported for 37 locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors. Far-field data measured at 36 locations are normalized to standard meteorological conditions and extrapolated from 10 - 1600 meters to derive sets of equal-value contours for these same seven acoustic measures as functions of angle and distance from the source.
USAF bioenvironmental noise data handbook. Volume 161: A/M32A-86 generator set, diesel engine driven
NASA Astrophysics Data System (ADS)
Rau, T. H.
1982-05-01
The A/M32A-86 generator set is a diesel engine driven source of electrical power used for the starting of aircraft, and for ground maintenance. This report provides measured and extrapolated data defining the bioacoustic environments produced by this unit operating outdoors on a concrete apron at normal rated/loaded conditions. Near-field data are reported for 37 locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors. Far-field data measured at 36 locations are normalized to standard meteorological conditions and extrapolated from 10 - 1600 meters to derive sets of equal-value contours for these same seven acoustic measures as functions of angle and distance from the source.
Li, Ning; Tsushima, Eiki; Tsushima, Hitoshi
2013-04-05
Use of hip protectors and compliant flooring has been recommended for preventing hip fracture due to falls. We aimed to identify the factors attenuating forces in falls by comparing and analyzing the impact forces occurring with various combinations of hip protectors and flooring materials. We designed a simplified pendulum device to simulate the impact force at the hip during falling. The impact force was measured on pressure-sensitive recording film under combined conditions of two kinds of hip protector (hard or soft shell) and three kinds of floor material (concrete, wooden, or tatami matting). We then calculated the percentage force attenuation under each test condition compared with the use of a concrete floor and no hip protector. All the tests using tatami matting reduced the impact to below the average fracture threshold of elderly people (3472N). A combination of tatami and soft hip protector provided the best attenuation (72.5%). Multiple regression analyses showed that use of tatami matting and a soft hip protector had the biggest force-attenuation effect. The soft hip protector gave better percentage force attenuation than did the hard one. Use of tatami matting as a flooring material could be an effective strategy for helping prevent hip fractures. Copyright © 2013 Elsevier Ltd. All rights reserved.
Yamane, Kentaro; Kai, Nobuo; Miyamoto, Tadashi; Matsushita, Tomohiro
2017-03-01
Exposure to radiation over many years prompts concerns regarding potential health-related effects, particularly the incidence of cataracts and the development of cancer. The purpose of this study was to examine and compare the exposure of the examiner to radiation during myelography versus radiculography and root block. A total of 114 examinations were performed in our institute in the 6 months. Sixty-two examinations were performed during myelography in the first 3 months (MG group), while 52 were performed during radiculography and root block in the last 3 months (RB group). The examiner wore a torso protector, a neck protector, radiation protection gloves, and radiation protection glasses. Optically stimulated luminescence (OSL) dosimeter badges were placed on both the inside and the outside of each protector. The dosimeters were exchanged every month. Radiation doses (mSv) were measured as the integrated radiation quantity every month from the OSL dosimeters. The effective dose and the equivalent doses of hand, skin, and eyes were investigated. The mean equivalent doses were significantly lower outside the neck, torso, eye protectors, and inside the torso protector in the RB group than in the MG group. Conversely, the mean equivalent dose was significantly lower outside the hand protector in the MG group than in the RB group. The use of a neck protector significantly decreased the effective dose compared to the non-use of a neck protector in the RB group. The present study showed the standard radiation exposure to the examiner during myelography, radiculography, and root block. Receiving full protection including a neck protector and protection gloves is an easy and reliable means to reduce radiation exposure. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Woo, J.H.; Ko, J.Y.; Choi, E.Y.; O'Sullivan, D.M.
2013-01-01
The axe kick, in Olympic style taekwondo, has been identified as the most popular scoring technique aimed to the head during full contact competition. The first purpose of this study was to identify and investigate design issues with the current World Taekwondo Federation approved chest protector. A secondary purpose was to develop a novel chest protector addressing the identified design issues and to conduct a biomechanical analysis. Fifteen male elite Taekwondo players were selected to perform three different styles of the axe kick, i.e., front, in-out, and out-in axe kick five times each for a total of 45 kicks. Two-way repeated measures ANOVA showed significant differences between the novel and existing chest protector conditions for vertical height of the toe, downward kicking foot speed, hip flexion angle and ipsilateral shoulder flexion extension range of motion (ROM) (p < 0.05). There were no significant differences between the control condition (no chest protector) and the novel chest protector condition for these variables (p > 0.05). These results indicate that the novel chest protector interferes less with both the lower and upper limbs during the performance of the axe kick and provides a more natural, free-moving alternative to the current equipment used. PMID:24744466
The Use of Hip Protectors in Long-Term Care Facilities: A Survey of Nursing Home Staff
Sawka, Anna M.; Nixon, Madeline; Giangregorio, Lora; Thabane, Lehana; Adachi, Jonathan D.; Gafni, Amiram; Goeree, Ron; Raina, Parminder; Ranford, Jennifer; Papaioannou, Alexandra
2016-01-01
Objectives To determine the level of exposure to hip protectors and barriers to their use in nursing homes. Design, Setting, and Participants We conducted a written survey of 160 staff (including administrators) in 5 nursing homes in the Hamilton-Wentworth region, Ontario, Canada. Measurements The results of primary analyses were expressed as percentage of respondents. Results Among respondents of respective institutions, the rate of prior exposure to hip protectors varied from 40.9% to 100.0% and the rate of prior experience applying these devices varied from 14.3% to 80.0%. The most frequently cited main barriers to the use of hip protectors in long-term care facilities included physicians not thinking to prescribe them, expense, lack of evidence of benefit in this population, wearer discomfort, and wearer removal. A lack of staff time to apply these devices was rarely cited. The majority of staff believed that nursing home residents with a prior history of fracture, those who fall frequently, or those who are unsteady on their feet should wear hip protectors. Conclusions The exposure of surveyed nursing home staff to hip protectors was variable but most agreed that residents who are at increased risk of hip fracture should wear them. Some identified barriers to the use of hip protectors in long-term care facilities were physicians not thinking to prescribe them, expense, lack of evidence of benefit in this population, wearer discomfort, and wearer removal. Such barriers need to be addressed for hip protector implementation strategies to be successful in nursing homes. PMID:17498606
30 CFR 62.160 - Hearing protectors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... REGULATIONS OCCUPATIONAL NOISE EXPOSURE § 62.160 Hearing protectors. (a) A mine operator must provide a hearing protector to a miner whose noise exposure equals or exceeds the action level under § 62.120 of this part. In addition, the mine operator must: (1) Train the miner in accordance with § 62.180 of this...
[Gonad protective effect of radiation protective apron in chest radiography].
Hashimoto, Masatoshi; Kato, Hideyuki; Fujibuchi, Toshiou; Ochi, Shigehiro; Morita, Fuminori
2004-12-01
Depending on the facility, a radiation protective apron (protector) is used to protect the gonad from radiation exposure in chest radiography. To determine the necessity of using a protector during chest radiography, we measured the effect of the protector on the gonad in this study. First, using a human body phantom, we measured the absorbed dose of the female gonad with and without the protector, using a thermoluminescence dosimeter (TLD), and confirmed its protective effect. Using the protector, the absorbed dose was reduced to 28+/-2% and 39+/-4% for field sizes of 14 x 17 inch and 14 x 14 inch, respectively. Next, we used Monte Carlo simulation and confirmed, not only the validity of the actual measurement values, but also the fact that the influence of radiation on the absorbed dose of the gonad was mostly from scattered radiation from inside the body for the 14 x 17 inch field size, and also from the X-ray tube for the 14 x 14 inch field size. Although a certain protective effect is achieved by using the protector, the radiation dose to the gonad is only a few microGy even without a protector. Thus, the risk of a genetic effect would be as small as 10(-8). Given that acceptable risk is below 10(-6), we conclude the use of a radiation protective apron is not necessary for diagnostic chest radiography.
49 CFR 227.115 - Hearing protectors.
Code of Federal Regulations, 2011 CFR
2011-10-01
... employees exposed to sound levels that meet or exceed the action level. (c) Required use at action level. A railroad shall require the use of hearing protectors when an employee is exposed to sound levels that meet... hearing protectors when an employee is exposed to sound levels equivalent to an 8-hour TWA of 90 dB(A) or...
Schools as Protectorates: Stories Two Mi'kmaq Mothers Tell
ERIC Educational Resources Information Center
Pushor, Debbie; Murphy, Bill
2010-01-01
In 1965, Memmi introduced the concept of a protectorate. "Whenever the colonizer states, in his language, that the colonized is a weakling, he suggests thereby that this deficiency requires protection. From this comes the concept of a protectorate" (pp. 147-8). While this concept is 45 years old, it is an apt metaphor for thinking about…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bobrov, Yu. K.; Zhuravkov, I. V.; Ostapenko, E. I.
2010-12-15
The effect of air gap breakdown voltage reduction in the circuit with an opening microswitch is substantiated from the physical point of view. This effect can be used to increase the efficiency of lightning protection system with a rod lightning protector. The processes which take place in the electric circuit of a lightning protector with a microswitch during a voltage breakdown are investigated. Openings of the microswitch are shown to lead to resonance overvoltages in the dc circuit and, as a result, efficient reduction in the breakdown voltage in a lightning protector-thundercloud air gap.
Emmerich, Edeltraut; Rudel, Lars; Richter, Frank
2008-07-01
The sound in classical orchestral music is louder than noise emissions allowed by national rules in industry. We wanted to assess the audiologic status of professional musicians at different ages of their careers and to look for a coherence of declined hearing ability and the sound emissions in order to substantiate advices for hearing protection and occupational medicine in musicians. Data from questionnaires (anamnestic data on sound exposure in profession and leisure times, use of hearing protection, self-evaluation of hearing function and hearing deficits), audiometric data and amplitudes of OAE were evaluated from 109 professional musicians aged 30-69 years from three major German orchestras and from 110 students of an academy of music (aged 11-19 years). Sound emissions of the whole orchestra and of single instruments/instrument groups were measured at the orchestra stages and pits during rehearsals and performances. None of the musicians was engaged in noisy hobbies and only a few used hearing protectors regularly. More than 50% of the musicians had a hearing loss of 15 dB(A) and more. Highest losses were found among the strings and the brass players. DPOAE amplitudes coincidently declined with the duration of performing music in the orchestras. Professional musicians aged older than 60 years had a significantly greater hearing loss at 4 and 6 kHz than those aged 30-39 years. Among the strings in one orchestra a dominant hearing deficit in the left ears was observed. Musicians need the same health care for their hearing as workers in noisy industry. A better education on the hearing hazards (use of hearing protectors) as well as sound protection in the rehearsal rooms is necessary. Hearing loss in professional musicians should be accepted as an occupational disease.
Mise au point d'un bouchon d'oreille "intelligent"
NASA Astrophysics Data System (ADS)
Voix, Jeremie
Many workers are exposed to noise levels high enough to put them at risk of losing their hearing. However, noise reduction at the source, when technically feasible, is often difficult to implement for economical reasons. Therefore, individual hearing protection remains the most widespread solution in practice. Unfortunately, the hearing protectors currently available on the market are seldom worn continuously as they should be (because they are not very comfortable or must be removed to communicate) and do not match the worker's need for protection (because their actual attenuation is generally unknown). This doctorate thesis work, carried out in close collaboration with SONOMAX HEARING HEALTHCARE I NC., had the general objective to develop a smart earplug that would solve the problems associated with current hearing protection devices thereby effectively preventing noise induced hearing loss in the industrial environment. The issues associated to this development have been formulated in details under the Health and Safety aspect (non-continuous wearing of the hearing protector and un-adapted protection), technical aspects (development of an earplug that is comfortable both from the physical and sound perception points of view and whose performances are measurable) and scientific aspects (modeling of physical systems, signal processing, instrumentation and measurement techniques). The technical developments have resulted in a custom earplug that is instantly fitted to the wearer's ear by silicone injection. Its acoustical performance can be measured using a microphone probe while the attenuation can be adapted to the user's need by the insertion through the earplug of passive acoustical filters. The scientific developments have resulted in the prediction of the attenuation of the earplug from the Noise Reduction measurement and in the prediction of the filtered earplug attenuation.
The Effects of Athletic Mouth Protectors upon Work of Breathing during Exercise
1990-01-01
in this investigation. Participants were issued each of the following types of commonly-available...ahead of other types of injuries in college football during the 1950 football season.(44) In 1952, Cathcart published the results of a joint survey...pressure and deformation were measired without a mouth protector in place, and with each of two types of mouth protectors in place. The researcher.
Eye Injuries in Canadian Racquet Sports
Pashby, Thomas J.; Bishop, Patrick J.; Easterbrook, W. Michael
1982-01-01
Racquet sports eye injuries have increased steadily in recent years. To determine the magnitude of the problem, the Canadian Ophthalmological Society (COS) Athletic Eye Injury Committee has sent questionnaires to COS members since 1976 to be completed for all racquet sports eye injuries treated. In the first year of the questionnaire 48 injuries were reported, including three legally blind eyes. From July 1978 to May 1981, 154 squash and 91 racquetball eye injuries were reported. Half the injured players required hospitalization and surgery was frequent; some players had permanent vision loss. These findings led to assessment of available eye protectors. Open-type protectors can be penetrated by balls and some closed-type protectors are not sufficiently sturdy. Steps are underway to write a Canadian standard for racquet sports eye protectors. Meanwhile the public must be informed of the danger of racquet sports eye injuries and the importance of wearing closed-type protectors. ImagesFig. 1Fig. 2Fig. 3Fig. 4Fig. 5Fig. 6 PMID:21286105
49 CFR 227.115 - Hearing protectors.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., DEPARTMENT OF TRANSPORTATION OCCUPATIONAL NOISE EXPOSURE Occupational Noise Exposure for Railroad Operating... railroad shall provide training in the use and care of all hearing protectors provided to employees. (6...
Comparison of friction produced by two types of orthodontic bracket protectors
Mendonça, Steyner de Lima; Praxedes Neto, Otávio José; de Oliveira, Patricia Teixeira; dos Santos, Patricia Bittencourt Dutra; Pinheiro, Fábio Henrique de Sá Leitão
2014-01-01
Introduction Fixed orthodontic appliances have been regarded as a common causative factor of oral lesions. To manage soft tissue discomfort, most orthodontists recommend using a small amount of utility wax over the brackets in order to alleviate trauma. This in vitro study aimed at evaluating friction generated by two types of bracket protectors (customized acetate protector [CAP] and temporary resin protector [TRP]) during the initial stages of orthodontic treatment. Methods An experimental model (test unit) was used to assess friction. In order to measure the friction produced in each test, the model was attached to a mechanical testing machine which simulated maxillary canines alignment. Intergroup comparison was carried out by one-way ANOVA with level of significance set at 5%. Results The friction presented by the TRP group was statistically higher than that of the control group at 6 mm. It was also higher than in the control and CAP groups in terms of maximum friction. Conclusion The customized acetate protector (CAP) demonstrated not to interfere in friction between the wire and the orthodontic bracket slot. PMID:24713564
Comparison of friction produced by two types of orthodontic bracket protectors.
de Lima Mendonça, Steyner; Praxedes Neto, Otávio José; de Oliveira, Patricia Teixeira; dos Santos, Patricia Bittencourt Dutra; de Sá Leitão Pinheiro, Fábio Henrique
2014-01-01
Fixed orthodontic appliances have been regarded as a common causative factor of oral lesions. To manage soft tissue discomfort, most orthodontists recommend using a small amount of utility wax over the brackets in order to alleviate trauma. This in vitro study aimed at evaluating friction generated by two types of bracket protectors (customized acetate protector [CAP] and temporary resin protector [TRP]) during the initial stages of orthodontic treatment. An experimental model (test unit) was used to assess friction. In order to measure the friction produced in each test, the model was attached to a mechanical testing machine which simulated maxillary canines alignment. Intergroup comparison was carried out by one-way ANOVA with level of significance set at 5%. The friction presented by the TRP group was statistically higher than that of the control group at 6 mm. It was also higher than in the control and CAP groups in terms of maximum friction. The customized acetate protector (CAP) demonstrated not to interfere in friction between the wire and the orthodontic bracket slot.
Bressan, Alexsander K; Roberts, Derek J; Edwards, Janet P; Bhatti, Sana U; Dixon, Elijah; Sutherland, Francis R; Bathe, Oliver; Ball, Chad G
2014-08-21
Among surgical oncology patients, incisional surgical site infection is associated with substantially increased morbidity, mortality and healthcare costs. Moreover, while adults undergoing pancreaticoduodenectomy with preoperative placement of an intrabiliary stent have a high risk of this type of infection, and wound protectors may significantly reduce its risk, no relevant studies of wound protectors yet exist involving this patient population. This study will evaluate the efficacy of a dual-ring wound protector for prevention of incisional surgical site infection among adults undergoing pancreaticoduodenectomy with preoperatively-placed intrabiliary stents. This study will be a parallel, dual-arm, randomised controlled trial that will utilise a more explanatory than pragmatic attitude. All adults (≥18 years) undergoing a pancreaticoduodenectomy at the Foothills Medical Centre in Calgary, Alberta, Canada with preoperative placement of an intrabiliary stent will be considered eligible. Exclusion criteria will include patient age <18 years and those receiving long-term glucocorticoids. The trial will employ block randomisation to allocate patients to a commercial dual-ring wound protector (the Alexis Wound Protector) or no wound protector and the current standard of care. The main outcome measure will be the rate of surgical site infection as defined by the Centers for Disease Control and Prevention criteria within 30 days of the index operation date as determined by a research assistant blinded to treatment allocation. Outcomes will be analysed by a statistician blinded to allocation status by calculating risk ratios and 95% CIs and compared using Fisher's exact test. This will be the first randomised trial to evaluate the efficacy of a dual-ring wound protector for prevention of incisional surgical site infection among patients undergoing pancreaticoduodenectomy. Results of this study are expected to be available in 2016/2017 and will be disseminated using an integrated and end-of-grant knowledge translation strategy. ClinicalTrials.gov identifier NCT01836237. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Individual Fit Testing of Hearing Protection Devices Based on Microphone in Real Ear.
Biabani, Azam; Aliabadi, Mohsen; Golmohammadi, Rostam; Farhadian, Maryam
2017-12-01
Labeled noise reduction (NR) data presented by manufacturers are considered one of the main challenging issues for occupational experts in employing hearing protection devices (HPDs). This study aimed to determine the actual NR data of typical HPDs using the objective fit testing method with a microphone in real ear (MIRE) method. Five available commercially earmuff protectors were investigated in 30 workers exposed to reference noise source according to the standard method, ISO 11904-1. Personal attenuation rating (PAR) of the earmuffs was measured based on the MIRE method using a noise dosimeter (SVANTEK, model SV 102). The results showed that means of PAR of the earmuffs are from 49% to 86% of the nominal NR rating. The PAR values of earmuffs when a typical eyewear was worn differed statistically ( p < 0.05). It is revealed that a typical safety eyewear can reduce the mean of the PAR value by approximately 2.5 dB. The results also showed that measurements based on the MIRE method resulted in low variability. The variability in NR values between individuals, within individuals, and within earmuffs was not the statistically significant ( p > 0.05). This study could provide local individual fit data. Ergonomic aspects of the earmuffs and different levels of users experience and awareness can be considered the main factors affecting individual fitting compared with the laboratory condition for acquiring the labeled NR data. Based on the obtained fit testing results, the field application of MIRE can be employed for complementary studies in real workstations while workers perform their regular work duties.
Pirayesh Islamian, Jalil; Mehrali, Habib
2015-01-01
Radio-protectors are agents that protect human cells and tissues from undesirable effects of ionizing radiation by mainly scavenging radiation-induced free radicals. Although chemical radio-protectors diminish these deleterious side effects they induce a number of unwanted effects on humans such as blood pressure modifications, vomiting, nausea, and both local and generalized cutaneous reactions. These disadvantages have led to emphasis on the use of some botanical radio-protectants as alternatives. This review has collected and organized studies on a plant-derived radio-protector, lycopene. Lycopene protects normal tissues and cells by scavenging free radicals. Therefore, treatment of cells with lycopene prior to exposure to an oxidative stress, oxidative molecules or ionizing radiation may be an effective approach in diminishing undesirable effects of radiation byproducts. Studies have designated lycopene to be an effective radio-protector with negligible side effects. PMID:25685729
[Means and methods of acoustic protection in aviation: current status and outlook for development].
Soldatov, S K; Bogomolov, A V; Zinkin, V N; Aver'ianov, A A; Rossel's, A V; Patskin, G A; Sokolov, B A
2011-01-01
Analysis of the current status of acoustic protection in aviation shows that despite the material progress in the field, risk of professional pathologies in flying and technical personnel is still high. The situation is dramatized by the lack of effective personal and crew acoustic protectors. The authors speculate on applicability of innovative materials and technologies, ingenious designs of earphones and modular prefabricated demountable structures. Tests of proposed personal protectors demonstrated their competitiveness with foreign analogs. Prospective lines of development, e.g. incorporation of active sound absorption systems in existing passive protectors are discussed.
A method to reduce patient's eye lens dose in neuro-interventional radiology procedures
NASA Astrophysics Data System (ADS)
Safari, M. J.; Wong, J. H. D.; Kadir, K. A. A.; Sani, F. M.; Ng, K. H.
2016-08-01
Complex and prolonged neuro-interventional radiology procedures using the biplane angiography system increase the patient's risk of radiation-induced cataract. Physical collimation is the most effective way of reducing the radiation dose to the patient's eye lens, but in instances where collimation is not possible, an attenuator may be useful in protecting the eyes. In this study, an eye lens protector was designed and fabricated to reduce the radiation dose to the patients' eye lens during neuro-interventional procedures. The eye protector was characterised before being tested on its effectiveness in a simulated aneurysm procedure on an anthropomorphic phantom. Effects on the automatic dose rate control (ADRC) and image quality are also evaluated. The eye protector reduced the radiation dose by up to 62.1% at the eye lens. The eye protector is faintly visible in the fluoroscopy images and increased the tube current by a maximum of 3.7%. It is completely invisible in the acquisition mode and does not interfere with the clinical procedure. The eye protector placed within the radiation field of view was able to reduce the radiation dose to the eye lens by direct radiation beam of the lateral x-ray tube with minimal effect on the ADRC system.
7 CFR 3201.83 - Furniture cleaners and protectors.
Code of Federal Regulations, 2014 CFR
2014-01-01
... PROPERTY MANAGEMENT, DEPARTMENT OF AGRICULTURE GUIDELINES FOR DESIGNATING BIOBASED PRODUCTS FOR FEDERAL PROCUREMENT Designated Items § 3201.83 Furniture cleaners and protectors. (a) Definition. Products designed to clean and provide protection to the surfaces of household furniture other than the upholstery. (b...
7 CFR 3201.83 - Furniture cleaners and protectors.
Code of Federal Regulations, 2013 CFR
2013-01-01
... PROPERTY MANAGEMENT, DEPARTMENT OF AGRICULTURE GUIDELINES FOR DESIGNATING BIOBASED PRODUCTS FOR FEDERAL PROCUREMENT Designated Items § 3201.83 Furniture cleaners and protectors. (a) Definition. Products designed to clean and provide protection to the surfaces of household furniture other than the upholstery. (b...
Fukuda, Atsushi; Koshida, Kichiro; Yamaguchi, Ichiro; Takahashi, Masaaki; Kitabayashi, Keitarou; Matsubara, Kousuke; Noto, Kimiya; Kawabata, Chikako; Nakagawa, Hiroto
2004-12-01
Various pharmaceutical companies in Japan are making radioactive drugs available for positron emission tomography (PET) in hospitals without a cyclotron. With the distribution of these drugs to hospitals, medical check-ups and examinations using PET are expected to increase. However, the safety guidelines for radiation in the new deployment of PET have not been adequately improved. Therefore, we measured the shielding effect of a clinical X-ray protector and lead glass against annihilation radiation and gamma rays of (99m)Tc. We then calculated the shielding effect of a 0.25 mm lead protector, 1 mm lead, and lead glass using the EGS4 (Electron Gamma Shower Version 4) code. The shielding effects of 22-mm lead glass against annihilation radiation and gamma rays of (99m)Tc were approximately 31.5% and 93.3%, respectively. The clinical X-ray protector against annihilation radiation approximately doubled the skin-absorbed dose.
Government and African Control of Education in the Bechuanaland Protectorate, 1928-48.
ERIC Educational Resources Information Center
Mgadla, P. T.
1995-01-01
Presents an in-depth portrait of the British government's educational policy in the Bechuanaland protectorate. The government systematized the primary school syllabus, regularized payment and training of teachers, and established cattle post schools. However, blatant discrimination favored support of European schools over African and little…
Chung, King
2004-01-01
This is the second part of a review on the challenges and recent developments in hearing aids. Feedback and the occlusion effect pose great challenges in hearing aid design and usage. Yet, conventional solutions to feedback and the occlusion effect often create a dilemma: the solution to one often leads to the other. This review discusses the advanced signal processing strategies to reduce feedback and some new approaches to reduce the occlusion effect. Specifically, the causes of three types of feedback (acoustic, mechanical, and electromagnetic) are discussed. The strategies currently used to reduce acoustic feedback (i.e., adaptive feedback reduction algorithms using adaptive gain reduction, notch filtering, and phase cancellation strategies) and the design of new receivers that are built to reduce mechanical and electromagnetic feedback are explained. In addition, various new strategies (i.e., redesigned sound delivery devices and receiver-in-the-ear-canal hearing aid configuration) to reduce the occlusion effect are reviewed. Many manufacturers have recently adopted laser shell-manufacturing technologies to overcome problems associated with manufacturing custom hearing aid shells. The mechanisms of selected laser sintering and stereo lithographic apparatus and the properties of custom shells produced by these two processes are reviewed. Further, various new developments in hearing aid transducers, telecoils, channel-free amplification, open-platform programming options, rechargeable hearing aids, ear-level frequency modulated (FM) receivers, wireless Bluetooth FM systems, and wireless programming options are briefly explained and discussed. Finally, the applications of advanced hearing aid technologies to enhance other devices such as cochlear implants, hearing protectors, and cellular phones are discussed. PMID:15735871
A study of the high-frequency hearing thresholds of dentistry professionals
Lopes, Andréa Cintra; de Melo, Ana Dolores Passarelli; Santos, Cibele Carmelo
2012-01-01
Summary Introduction: In the dentistry practice, dentists are exposed to harmful effects caused by several factors, such as the noise produced by their work instruments. In 1959, the American Dental Association recommended periodical hearing assessments and the use of ear protectors. Aquiring more information regarding dentists', dental nurses', and prosthodontists' hearing abilities is necessary to propose prevention measures and early treatment strategies. Objective: To investigate the auditory thresholds of dentists, dental nurses, and prosthodontists. Method: In this clinical and experimental study, 44 dentists (Group I; GI), 36 dental nurses (Group II; GII), and 28 prosthodontists (Group III; GIII) were included, , with a total of 108 professionals. The procedures that were performed included a specific interview, ear canal inspection, conventional and high-frequency threshold audiometry, a speech reception threshold test, and an acoustic impedance test. Results: In the 3 groups that were tested, the comparison between the mean hearing thresholds provided evidence of worsened hearing ability relative to the increase in frequency. For the tritonal mean at 500 to 2,000 Hz and 3,000 to 6,000 Hz, GIII presented the worst thresholds. For the mean of the high frequencies (9,000 and 16,000 Hz), GII presented the worst thresholds. Conclusion: The conventional hearing threshold evaluation did not demonstrate alterations in the 3 groups that were tested; however, the complementary tests such as high-frequency audiometry provided greater efficacy in the early detection of hearing problems, since this population's hearing loss impaired hearing ability at frequencies that are not tested by the conventional tests. Therefore, we emphasize the need of utilizing high-frequency threshold audiometry in the hearing assessment routine in combination with other audiological tests. PMID:25991940
[Legislation on the pharmaceutical industry in Morocco during the French protectorate 1912 - 1956].
Nhaili, Hicham; Taoufik, Jamal
2015-06-01
In Morocco, the pharmaceutical industry was born with the French protectorate. She knew a great evolution: from a limited production for local needs, it became an important activity, organized to export pharmaceutical patent medicines. This article revisits the birth and history of this industry during the protectorate. It refers to the situation at the time by listing some examples of active establishments and some specialities marketed. It also aims to increase knowledge about the industry and provides an overview of the situation of practitioners remembering the texts governing the profession. Based on the available literature, we examined and analyzed the arrangements related to the establishment, organization and evolution of the pharmaceutical industry.
Intravenous insertion site protection: moisture accumulation in intravenous site protectors.
Lee, W E; Vallino, L M
1996-01-01
Stabilizing the intravenous catheter after insertion is a significant part of intravenous therapy. Dislodgments of the cannula from its optimal position in the vein can lead to complications such as phlebitis, thrombophlebitis, infiltration, and infection. Intravenous site protector shields are designed to protect the catheter from impact and tissue trauma at the insertion site. Nurses have requested ventilation in these shields to avoid moisture build up that may increase the risk of infections. To address this issue, experimental laboratory testing was performed to determine if moisture accumulation as evidenced by increased weight of the shield and visible evidence of condensation occurred. No moisture condensation problems with the ventilated intravenous site protectors were found.
Performance of Hearing Protectors in Impulse Noise
2000-09-01
report: ADPO10340 thru ADP010346 UNCLASSIFIED 3-1 Performance of Hearing Protectors in Impulse Noise K. Buck French German Research Institute BP 34...5 rue du G6n~ral Cassagnou 68301 Saint-Louis CEDEX France Summary adapted to the high levels to which the devices will The present paper describes the
Los Protectores del Planeta: actividades para niños y recursos educativos sobre reciclaje
Información sobre el Club Protectores del Planeta que enseña cómo reducir la basura desde el punto de origen, cómo reciclar y conservar los recursos naturales. La información incluye recursos educativos para el salón de clases.
NASA Astrophysics Data System (ADS)
Haris, A.; Goh, B. W. Y.; Tay, T. E.; Lee, H. P.; Rammohan, A. V.; Tan, V. B. C.
2018-01-01
The objective of this research is to develop a smart hip protector by incorporating shear thickening fluid (STF) into conventional foam hip protectors. The shear thickening properties of fumed silica particles dispersed in liquid polyethylene glycol (PEG) were determined from rheological tests. Dynamic drop tests, using a 4 kg drop platen at 0.5 m drop height, were conducted to study how STF improves energy absorption as compared to unfilled foam and PEG filled foam. The results show that PEG filled foam reduces the mean peak force transmitted by a further 55% and mean peak displacement by 32.5% as compared to the unfilled foam; the STF filled foam further reduces mean peak force and displacement by 15% and 41% respectively when compared to the PEG filled foam. At a displacement of 22 mm, the STF filled foam absorbs 7.4 times more energy than the PEG filled foam. The results of varying the drop mass and drop height show that the energy absorbed per unit displacement for STF filled foam is always higher than that of PEG filled foam. Finally, the effectiveness of a prototype of hip protector made from 15 mm thick STF filled foam in preventing hip fractures was studied under two different loading conditions: distributed load (plate drop test) and concentrated load (ball drop test). The results of the plate and ball drop tests show that among all hip protectors tested in this study, only the prototype can reduce the mean peak impact force to be lower than the force required to fracture a hip bone (3.1 kN) regardless of the type of loading. Moreover, the peak force of the prototype is about half of this value, suggesting thinner prototype could have been used instead. These findings show that STF is effective in improving the performance of hip protectors.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-08
... (including green tubes and limited service OCTG products), whether or not thread protectors are attached. The... thread protectors. The merchandise covered by the order is currently classified in the Harmonized Tariff....1: Non-Market Economy Surrogate Country Selection Process (March 1, 2004). \\21\\ See Factor Valuation...
49 CFR Appendix B to Part 227 - Methods for Estimating the Adequacy of Hearing Protector Attenuation
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Methods for Estimating the Adequacy of Hearing..., App. B Appendix B to Part 227—Methods for Estimating the Adequacy of Hearing Protector Attenuation This appendix is mandatory. Employers must select one of the following three methods by which to...
40 CFR 211.204-3 - Label location and type.
Code of Federal Regulations, 2010 CFR
2010-07-01
... packaging if the label complying with § 211.204-3(a)(1) is not visible at the point of ultimate purchase or...) If the protector is individually packaged and so displayed at the point of ultimate purchase or... the protector is displayed at the point of ultimate purchase or distribution to prospective users in a...
Hearing protection for clubbers is music to their ears.
Beach, Elizabeth; Williams, Warwick; Gilliver, Megan
2010-12-01
while it is difficult to promote the use of hearing protectors in noisy workplaces and leisure settings, some nightclub attendees choose to wear earplugs when exposed to loud music. This qualitative study investigated the perceptions of clubbers about the advantages and disadvantages of earplug use in nightclubs. Such first-hand information could potentially be used to educate non-wearers about the features of different earplug types, the experience of wearing earplugs and their relative merits. structured telephone interviews were conducted with 20 regular clubbers who wear different types of earplugs at nightclubs. Participants were asked about their experience of wearing earplugs and, in particular, what they perceive to be the advantages and disadvantages of earplugs. participants' responses revealed that cheaper foam earplugs are considered less satisfactory than more expensive earplugs, which are relatively discreet and comfortable, facilitate communication with others, create minimal music distortion and, in some cases, improve music sound quality. In terms of effectiveness, all types of earplugs were considered beneficial in reducing the after-effects of loud music and providing hearing protection. the perceived advantages of earplugs, which are often not recognised by non-earplug wearers, should be communicated in order to encourage the use of earplugs among clubbers.
USAF Bioenvironmental Noise Data Handbook. Volume 160: KC-10A aircraft, near and far-field noise
NASA Astrophysics Data System (ADS)
Powell, R. G.
1982-09-01
The USAF KC-10A aircraft is an advanced tanker/cargo aircraft powered by three CF6-50C2 turbofan engines. This report provides measured and extrapolated data defining the bioacoustic environments produced by this aircraft operating on a concrete runup pad for eight engine/power configurations. Near-field data are reported for one location in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference levels, perceived noise levels, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors. Far-field data measured at 15 locations are normalized to standard meteorological conditions and extrapolated from 75-8000 meters to derive sets of equal-value contours for these same seven acoustic measures as functions of angle and distance from the source. Refer to Volume 1 of this handbook, USAF Bioenvironmental Noise Data Handbook, Vol 1: Organization, Content and Application, AMRL-TR-75-50(1) 1975, for discussion of the objective and design of the handbook, the types of data presented, measurement procedures, instrumentation, data processing, definitions of quantities, symbols, equations, applications, limitations, etc.
Ma, Wenchao; Wenga, Terrence; Zhang, Nan; Chen, Guanyi; Yan, Beibei; Zhou, Zhihua; Wu, Xiao
2017-12-13
Municipal solid waste (MSW) incineration is widely adopted as a waste management strategy and for the energy production. However, this technology experience grave deposition and corrosion of the boiler tubes due to high chlorine (~1.09wt.%) and alkali metal (Na, K) content in MSW. Little is known about the concentration profile of these corrosive elements in the deposits at different boiler locations. Therefore, a full-scale experimental investigation was conducted to determine the concentration profile of Cl, K, Na, S, and Ca in the deposits at pre-protector and compare with those at 3 rd superheater during MSW combustion at a 36 MWe waste incineration plant (WIP) in Chengdu, China. The deposit samples were analyzed using wet chemical techniques, scanning electron microscope coupled with energy dispersive spectroscopy (SEM/EDS), and X-ray diffraction (XRD). The concentrations of Na, K, and Cl were high in the deposits at pre-protector while S and Ca concentrations were high on the 3 rd superheater. The pre-protector was severely corroded than the 3 rd superheater. The governing mechanisms for the deposition and corrosion on these boiler locations were elucidated.
Hearing protector fit testing with off-shore oil-rig inspectors in Louisiana and Texas.
Murphy, William J; Themann, Christa L; Murata, Taichi K
2016-11-01
This field study aimed to assess the noise reduction of hearing protection for individual workers, demonstrate the effectiveness of training on the level of protection achieved, and measure the time required to implement hearing protector fit testing in the workplace. The National Institute for Occupational Safety and Health (NIOSH) conducted field studies in Louisiana and Texas to test the performance of HPD Well-Fit. Fit tests were performed on 126 inspectors and engineers working in the offshore oil industry. Workers were fit tested with the goal of achieving a 25-dB PAR. Less than half of the workers were achieving sufficient protection from their hearing protectors prior to NIOSH intervention and training; following re-fitting and re-training, over 85% of the workers achieved sufficient protection. Typical test times were 6-12 minutes. Fit testing of the workers' earplugs identified those workers who were and were not achieving the desired level of protection. Recommendations for other hearing protection solutions were made for workers who could not achieve the target PAR. The study demonstrates the need for individual hearing protector fit testing and addresses some of the barriers to implementation.
Undermining optimistic denial reactions to domestic and campus emergency warning messages.
Thompson, Suzanne C; Schlehofer, Michele M
2014-07-01
Individuals who prepare for public emergencies can mitigate the effects of an incident, but denial of personal susceptibility may reduce the likelihood of preparation. Some denial may be due to a positive self-image that is at odds with being "at risk". The potential for an enhanced warning message that included a positive image of a protector to circumvent this denial was tested in two studies. Optimistic denial threat orientation was measured. Then participants received either a traditional or a positive protector warning message about terrorism (Study 1; nationally representative sample of US adults; N = 587) or campus emergency preparation (Study 2; US college students; N = 179). As predicted, in the enhanced image condition optimistic denial was no longer related to stronger denial reactions and lower intentions to protect oneself. In addition, Study 2 tested explanatory mediators and found that negative perceptions of and low similarity to a protector partially explained the denial of those higher in optimistic denial and why their denial was dampened in the positive image condition. An enhanced message including a positive image of protector may be an effective way to encourage protection for those prone to optimistic denial. © 2014 The International Association of Applied Psychology.
Musician earplugs: Appreciation and protection
Bockstael, Annelies; Keppler, Hannah; Botteldooren, Dick
2015-01-01
Recreational music exposure is a potential risk factor for noise-induced hearing loss (NIHL). Augmented hearing protectors have been designed with modified attenuation characteristics to combine hearing protection and listening comfort. However, to date, only a few independent studies have assessed the performance of those augmented protectors in realistic exposure conditions. This study compares the listening experience and temporary effects on cochlear status with different types of earplugs after exposure to contemporary club music. Five different types of commercially available hearing protectors were worn, all commonly used during leisure-time music exposure. Four of them were augmented premolded earplugs and the fifth type was an inexpensive, standard earplug frequently distributed for free at music events. During five different test sessions of 30 min each, participants not professionally involved in music wore one particular type of protector. Contemporary club music was played at sound pressure levels (SPLs) representative of concerts and bars. After each listening session, a questionnaire on sound quality and general appreciation was completed. In addition, otoacoustic emissions (OAEs) were measured directly before and after music exposure. The reported appreciation clearly differed depending on the addressed characteristics and the specific earplug type. In this test group, the reported appreciation mainly depended on comfort and looks, while differences in sound quality were less noticeable. The changes in OAE amplitude before and after noise exposure were small in terms of clinical standards. Nevertheless, the observed temporary shifts differed systematically for the different types of hearing protectors, with two types of musician earplug showing a more systematic decline than the others. Further research with respect to actual use and achieved protection for real, unsupervised music exposure is warranted. PMID:26168950
Pinar Erdem, Arzu; Sepet, Elif; Kulekci, Güven; Trosola, Sule Can; Guven, Yegane
2012-01-01
Aims: The aim of this study was to evaluate and to compare the effect of two fluoride varnishes and one fluoride/chlorhexidine varnish on Streptococcus mutans and Streptococcus sobrinus biofilm formation, in vitro. Study design: Standard acrylic discs were prepared and divided into groups based on the varnish applied to the disc surface: Fluor Protector, Bifluoride 12, and Fluor Protector + Cervitec (1:1). Untreated discs served as controls. In the study groups, biofilms of S. mutans and S. sobrinus were formed over 24 h, 48 h, and 5 days. The fluoride concentrations in the monospecies biofilms and viable counts of S. mutans and S. sobrinus were investigated. Results: In all study groups, a statistically significant increase in the viable number of S. mutans and S. sobrinus cells was observed between 24 h and 5 days. In both monospecies biofilms, the greatest antibacterial efficacy was detected in the Fluor Protector and Fluor Protector + Cervitec groups at 24 h. For all groups, the amount of fluoride released was highest during the first 24 h, followed by a significant decrease over the next 4 days. A negative correlation was detected between fluoride concentration and antibacterial effect in those groups with biofilms containing both species. Despite the release of high levels of fluoride, the greatest number of viable S. mutans and S. sobrinus cells was detected in the Bifluoride 12 group. Statistics: The data were analyzed using GraphPad Prism software (ver. 3). Conclusions: The Fluor Protector + Cervitec varnish exerted prolonged antibacterial effects on S. mutans and S. sobrinus biofilms compared to the other varnishes tested. PMID:22253559
Ibrahim, Ahmed Mohamed; Borai, Ibrahim Hassan; Ali, Mamdouh Moawad; Ghanem, Hala Mostafa; Hegazi, Azza El-Sayed Ahmed; Mousa, Amria Mamdouh
2013-05-01
This study was aimed to evaluate protective and therapeutic effects of a specific mixture, containing vitamin C, lysine, proline, epigallocatechin gallate and zinc, as well as alpha-1-antitrypsin protein on lung tumorigenesis induced by benzo(a) pyrene [B(a)P] in mice. Swiss albino mice were divided into two main experiments, experiment (1) the mice were injected with 100 mg/kg B(a)P and lasted for 28 weeks, while experiment (2) the mice were injected with 8 doses each of 50 mg/kg B(a)P and lasted for 16 weeks. Each experiment (1 and 2) divided into five groups, group (I) received vehicle, group (II) received the protector mixture, group (III) received the carcinogen B(a)P, group (IV) received the protector together with the carcinogen (simultaneously) and group (V) received the carcinogen then the protector (consecutively). Total sialic acid, thiobarbituric acid reactive substances, vascular epithelial growth factor, hydroxyproline levels, as well as elastase and gelatinase activities showed significant elevation in group (III) in the two experiments comparing to control group (P < 0.001). These biochemical alterations were associated with histopathological changes. Administration of the protector in group IV and group V causes significant decrease in such parameters with improvement in histopathological alterations with improvement in histopathological alterations when compared with group III in the two experiments (P < 0.001). The present protector mixture has the ability to suppress neoplastic alteration and restore the biochemical and histopathological parameters towards normal on lung carcinogenesis induced by benzo(a) pyrene in mice. Furthermore, the present mixture have more protective rather than therapeutic action.
Yamane, Kentaro; Kai, Nobuo; Mazaki, Tetsuro; Miyamoto, Tadashi; Matsushita, Tomohiro
2018-06-13
Long-term exposure to radiation can lead to gene mutations and increase the risk of cancer. Low rate fluoroscopy has the potential to reduce the radiation exposure for both the examiner and the patient during various fluoroscopic procedures. The purpose of this study was to evaluate the impact of low rate fluoroscopy on reducing an examiner's radiation dose during nerve root block. A total of 101 lumbar nerve root block examinations were performed at our institute during a 6-month period. During the first 3 months, low rate fluoroscopy was performed at 7.5 frames/s (FPS) in 54 examinations, while 47 were performed at 15 FPS during the last 3 months. The examiner wore a torso protector, a neck protector, radiation protection gloves, and radiation protection glasses. Optically stimulated luminescence (OSL) dosimeter badges were placed on both the inside and the outside of each protector. The dosimeters were exchanged every month. Radiation doses (mSv) were measured as the integrated radiation quantity every month from the OSL dosimeters. The effective and equivalent doses for the hands, skin, and eyes were investigated. The mean monthly equivalent doses were significantly lower both inside and outside the hand protector for the 7.5 FPS versus 15 FPS (inside; P = 0.021, outside; P = 0.024). There were no significant differences between the two groups for the mean monthly calculated effective dose for each protector's condition. Radiation exposure was significantly reduced for the skin on the examiner's hand when using low rate fluoroscopy at 7.5 FPS, with no noticeable decrease in image quality or prolonged fluoroscopy time. Copyright © 2018. Published by Elsevier B.V.
Musician earplugs: Appreciation and protection.
Bockstael, Annelies; Keppler, Hannah; Botteldooren, Dick
2015-01-01
Recreational music exposure is a potential risk factor for noise-induced hearing loss (NIHL). Augmented hearing protectors have been designed with modified attenuation characteristics to combine hearing protection and listening comfort. However, to date, only a few independent studies have assessed the performance of those augmented protectors in realistic exposure conditions. This study compares the listening experience and temporary effects on cochlear status with different types of earplugs after exposure to contemporary club music. Five different types of commercially available hearing protectors were worn, all commonly used during leisure-time music exposure. Four of them were augmented premolded earplugs and the fifth type was an inexpensive, standard earplug frequently distributed for free at music events. During five different test sessions of 30 min each, participants not professionally involved in music wore one particular type of protector. Contemporary club music was played at sound pressure levels (SPLs) representative of concerts and bars. After each listening session, a questionnaire on sound quality and general appreciation was completed. In addition, otoacoustic emissions (OAEs) were measured directly before and after music exposure. The reported appreciation clearly differed depending on the addressed characteristics and the specific earplug type. In this test group, the reported appreciation mainly depended on comfort and looks, while differences in sound quality were less noticeable. The changes in OAE amplitude before and after noise exposure were small in terms of clinical standards. Nevertheless, the observed temporary shifts differed systematically for the different types of hearing protectors, with two types of musician earplug showing a more systematic decline than the others. Further research with respect to actual use and achieved protection for real, unsupervised music exposure is warranted.
Risk by use of hearing protectors--expert programme supports SMEs in appropriate selection and use.
Liedtke, M
2005-01-01
Comprehensive protection by use of PPE against the hazards at work requires more than proper selection based on the protection level needed: The PPE user directive (Council Directive 89/656/EEC, Official Journal of the European Communities L 393, 30/12/1989 p.0018 - 0028) requires an assessment of personal protective equipment itself, which has to consider the risks which may be introduced by use of PPE or use of combinations of PPE. As an example risks which may be introduced by use of hearing protectors are described. Assistance in the assessment required by PPE user directive (Council Directive 89/656/EEC, Official Journal of the European Communities L 393, 30/12/1989 p. 0018 - 0028) and in selection and use of hearing protectors with regard to this assessment is presented.
Development of single-cell protectors for sealed silver-zinc cells
NASA Technical Reports Server (NTRS)
Lear, J. W.; Donovan, R. L.; Imamura, M. S.
1978-01-01
Three design approaches to cell-level protection were developed, fabricated, and tested. These systems are referred to as the single-cell protector (SCP), multiplexed-cell protector(MCP). To evaluate the systems 18-cell battery packs without cell level control were subjected to cycle life test. A total of five batteries were subjected to simulate synchronous orbit cycling at 40% depth of discharge at 22C. Batteries without cell-level protection failed between 345 and 255 cycles. Cell failure in the cell level protected batteries occurred between 412 and 540. It was determined that the cell-level monitoring and protection is necessary to attain the long cycle life of a AgZn battery. The best method of providing control and protection of the AgZn cells depends on the specific application and capability of the user.
Chistov, S D; Soldatov, S K; Zinkin, V N; Poliakov, N M
2013-01-01
The objective of the present study was to evaluate the hearing function in the airport technical personnel and estimate the effectiveness of multicomponent anti-noise hearing protectors used by the specialists engaged in the aircraft maintenance. The tonal threshold audiometry was carried out before and after a shiftwork. The extra-aural effect of noise was assessed from the characteristics of cardiac rhythm variability. The study included two groups of subjects: in one of them (n=8) they used ordinary flight headsets (control) in the other the protection was ensured with the help of multi-insert hearing protectors (n=16). The initial hearing thresholds were found to be increased up to 70 and 60 dB at the frequencies of 4 and 8 kHz respectively. The regression analysis revealed the relationship between these parameters and the duration of aerodrome work experience. Temporary threshold shifts were observed only in the control group. An increase in the tone of the sympathetic nervous system was observed in the control subjects but was absent in the study group. It is concluded that the multi-component hearing protectors employed in the present study are highly efficacious anti-noise devices. The mechanisms of noise-induced hearing loss are discussed.
Safety of laser use under the dental microscope.
Saegusa, Hidetoshi; Watanabe, Satoshi; Anjo, Tomoo; Ebihara, Arata; Suda, Hideaki
2010-04-01
The aim of this study was to investigate the safety of laser use under the dental microscope. Nd:YAG, Er:YAG and diode lasers were used. The end of the tips was positioned at a distance of 5 cm from the objective lens of a dental microscope. Each eye protector was made into a flat disc, which was fixed on the lens of the microscope. The filters were placed in front of the objective lens or behind the eye lens. Transmitted energy through the microscope with or without the filters was measured. No transmitted laser energy was detected when using matched eye protectors. Mismatched eye protectors were not effective for shutting out laser energy, especially for Nd:YAG and diode lasers. None or very little laser energy was detected through the microscope even without any laser filter. Matched filters shut out all laser energy irrespective of their positions.
Audibility of reverse alarms under hearing protectors for normal and hearing-impaired listeners.
Robinson, G S; Casali, J G
1995-11-01
The question of whether or not an individual suffering from a hearing loss is capable of hearing an auditory alarm or warning is an extremely important industrial safety issue. The ISO Standard that addresses auditory warnings for workplaces requires that any auditory alarm or warning be audible to all individuals in the workplace including those suffering from a hearing loss and/or wearing hearing protection devices (HPDs). Research was undertaken to determine how the ability to detect an alarm or warning signal changed for individuals with normal hearing and two levels of hearing loss as the levels of masking noise and alarm were manipulated. Pink noise was used as the masker and a heavy-equipment reverse alarm was used as the signal. The rating method paradigm of signal detection theory was used as the experimental procedure to separate the subjects' absolute sensitivities to the alarm from their individual criteria for deciding to respond in an affirmative manner. Results indicated that even at a fairly low signal-to-noise ratio (0 dB), subjects with a substantial hearing loss [a pure-tone average (PTA) hearing level of 45-50 dBHL in both ears] were capable of hearing the reverse alarm while wearing a high-attenuation earmuff in the pink noise used in the study.
[Proximal femoral fractures in the elderly: pathogenesis, sequelae, interventions].
Runge, M; Schacht, E
1999-08-01
Hip fractures are a health problem of paramount importance for the individual and society. They are associated with a sharp increase of the incidence of immobility, dependency, nursing home placement, and death. In Germany, more than 100,000 elderly suffer a hip fracture every year. 90% of fractures of the proximal femur result from a fall with an impact near the hip. The kinetic energy of a fall from standing height without successful protective reactions is far above the fracture threshold of a femur in a man aged 70 and older, regardless of osteoporosis and sex. Therefore, propensity to fall and mechanisms of falling are more important in the pathogenesis of hip fracture than bone mineral density alone. The combination of age-associated gait and balance disorders, which increase the probability of falls, and age-related decreasing strength of the femur is responsible for the high incidence of hip fractures. Besides the interventions to reduce the fall frequency it is possible to decrease the number of hip fractures by a passive protection of the trochanter. An energy-shunting protector (crash helmet-like, hip padding) has been developed by Lauritzen and Lund (safehip). The protector consists of two stiff shells, sewn into special undergarment. The shells disperse the impact away from the trochanter to soft tissue, and increase the area of contact. A controlled study among nursing home residents has demonstrated a relative risk of hip fracture of 0.44 (95% CC 0.21 to 0.94) in the intervention group, i.e., the protector has reduced the number of hip fractures by more than a half. No hip fracture has happened during use of the protector. Using the protector can improve self-confidence and diminish self-restraint of physical activity, which is not rarely caused by fear of falling. Further investigations of compliance are necessary.
Dragan, S P; Soldatov, S K; Bogomolov, A V; Drozdov, S V; Poliakov, N M
2013-01-01
Purpose of the investigation was to validate testing acoustic effectiveness of a personnel vest-like protector (PP) from extra-aural exposure to aviation noise. Levels of aviation noise for PP testing were determined through calculation. Vest effectiveness in protecting from acoustic vibration generated by high-intensity aviation noise was evaluated both in laboratory and field tests. For comparison analysis, PP was also tested with a dummy exposed on a special tester, i.e. acoustic interferometer.
Kobylianskiĭ, V I; Artiushkin, A V; Svetavskaia, M A
1999-01-01
To improve the efficiency of the therapy of respiratory diseases, the influence of a drug belonging to the group of actoprotectors--bemithyl (bemactor) on the main protector mechanisms of respiratory organs was evaluated, using functional-morphological studies of mucocilliary apparatus and local bronchial immunity. Bemithyl was found to produce no direct influence on these mechanisms, but the use of bemithyl by special technology is perspective for these purposes.
On the size of pores arising in erythrocytes under the action of detergents.
Senkovich, O A; Chernitsky, E A
1998-01-01
The size of pores arising in human erythrocytes under the action of two detergents (Triton X-100 and sodium dodecyl sulfate) and causing the slow component of hemolysis was estimated by the method of osmotic protectors. The pore diameters were found to be about 40 A. The pores responsible for the fast component of hemolysis induced by sodium dodecyl sulfate were shown to be of greater size and even molecules of polyethylene glycol 4000 could pass through them. The unusual decrease. In the rate and percentage of this hemolytic component was caused by the side action of the protectors, i.e., by the acceleration of erythrocyte vesiculation, a process that competed with pore formation. Vesiculation protected erythrocytes against fast and slow detergent-induced hemolysis. It is shown that the method of osmotic protectors can not be used for estimation of pore size in fast hemolysis by sodium dodecyl sulfate. The application of this method for hemolysis by other amphiphilic compounds is discussed.
Huynh, Hai P; Musselman, Reilly P; Trottier, Daniel C; Soto, Claudia M; Poulin, Eric C; Mamazza, Joseph; Boushey, Robin P; Auer, Rebecca C; Moloo, Husein
2013-10-01
To review surgical-site infection (SSI) and retrieval-site tumor recurrence rates in laparoscopic colorectal procedures when using a plastic freezer bag as a wound protector. Laparoscopic colorectal procedures where a plastic freezer bag used as a wound protector at the extraction site were reviewed between 1991 and 2008 from a prospectively collected database. χ test was used to compare SSI and tumor recurrence rates between groups. Costing data were obtained from the operating room supplies department. A total of 936 cases with 51 (5.45%) surgical-site infections were identified. SSI rates did not differ when comparing groups based on demographic factors, diagnosis, or location of procedure. Retrieval-site tumor recurrence rate was 0.21% (1/474). Cost of plastic freezer bags including sterilization ranged from $0.25 to $3. Plastic freezer bags as wound protectors in laparoscopic colorectal procedures are cost effective and have SSI and retrieval-site tumor recurrence rates that compare favorably to published data.
Kadowaki, Yoshihiko; Kurokawa, Takefumi; Tamura, Ryuji; Okamoto, Takahiro; Ishido, Nobuhiro; Mori, Takashi
2010-01-01
Lap-Protector, which is an abdominal wall sealing device, is usually used for wound protection from implantation of malignant cells or pyogenic fluid. A circular stapler is a common easy-to-use device for anastomosis of the digestive tract. We report the case of an infected pancreatic pseudocyst which was treated by surgical procedure using these useful devices. A 69-year-old man was followed up in our hospital after severe acute pancreatitis. He had undergone drainage surgeries twice for intractable pancreatic abscess followed by severe acute pancreatitis. He was admitted to our hospital complaining of loss of appetite, hiccups, and high fever. Computed tomography of the abdomen revealed an infected pancreatic pseudocyst which compressed the gastric wall. Internal drainage into the stomach was performed using Lap-Protector and circular stapler. The patient recovered uneventfully. Recently many endoscopic or laparoscopic procedures in cystogastrostomy are reported; however, a conventional open surgical approach is also important. This easy method may be useful for operative cystogastrostomy. PMID:20805947
RNA-stabilization factors in chloroplasts of vascular plants.
Manavski, Nikolay; Schmid, Lisa-Marie; Meurer, Jörg
2018-04-13
In contrast to the cyanobacterial ancestor, chloroplast gene expression is predominantly governed on the post-transcriptional level such as modifications of the RNA sequence, decay rates, exo- and endonucleolytic processing as well as translational events. The concerted function of numerous chloroplast RNA-binding proteins plays a fundamental and often essential role in all these processes but our understanding of their impact in regulation of RNA degradation is only at the beginning. Moreover, metabolic processes and post-translational modifications are thought to affect the function of RNA protectors. These protectors contain a variety of different RNA-recognition motifs, which often appear as multiple repeats. They are required for normal plant growth and development as well as diverse stress responses and acclimation processes. Interestingly, most of the protectors are plant specific which reflects a fast-evolving RNA metabolism in chloroplasts congruent with the diverging RNA targets. Here, we mainly focused on the characteristics of known chloroplast RNA-binding proteins that protect exonuclease-sensitive sites in chloroplasts of vascular plants. © 2018 The Author(s).
Surface Microbiology of Smartphone Screen Protectors Among Healthcare Professionals.
Raza, Ibrahim; Raza, Awais; Razaa, Syed Ahmad; Sadar, Ahmad Bani; Qureshi, Ahmad Uzair; Talib, Usama; Chi, Gerald
2017-12-26
The use of smartphones with touch screens has become a norm for healthcare professionals (HCP). The risk of smart screen contamination has been proven, and guidelines are available to deal with possible contamination. A large number of smartphone users apply plastic or glass screen protectors onto their mobile phone screens to prevent scratches. However, these materials are not scratch proof, and their antipathogenic properties have not been studied. We have conducted a study to determine the frequency of smartphone screen protector contamination and compared the data with contamination on the bare area on the same mobile screens. The sample size included only HCPs working in acute care settings and having at least eight hours of exposure time every day. A total of 64 samples were collected, which reported 62.5% (n = 40/64) positive culture swabs from the protected areas of the screen and 45.3% (n = 29/64) from the unprotected area of the screen. Micrococcus and Gram-negative rods grew only on samples taken from the protected area whereas the bare area showed no such growth. There was no statistically significant difference in the frequency based on smart screen size, duration of use during duty hours, or the setting where it was used. Smartphone screen protectors from healthcare providers may harbor pathogenic bacteria, especially in acute care settings. Coagulase-negative Staphylococci followed by Bacillus species were the most commonly yielded bacteria among house officers and postgraduate trainees in the present study.
NASA Astrophysics Data System (ADS)
Sehn, E.; Silva, K. C.; Bento, A. C.; Baesso, M. L.; Franco, S. L.
2005-06-01
In this work, the Photoacoustic Spectroscopy was employed to evaluate the potentiality of bee-propolis as UV protector. The experiments were performed to obtain the creams optical absorption spectra in the UV spectral region and also to evaluate in vivo the penetration rate of the obtained product in humans. The results showed the spectral response of the developed bee-propolis creams, and also revealed that two hours after the application about 40 % of the cream signal was still detected on the skin surface.
Casali, John G; Robinson, Gary S; Dabney, Erika Christian; Gauger, Dan
2004-01-01
An experiment was conducted wherein masked thresholds (using ascending method of limits) for a backup alarm were obtained in pink and red noise at 85 and 100 dBA for 12 participants immersed in a probability monitoring task and wearing a conventional passive hearing protection device (HPD, an earmuff or a foam earplug), an active noise reduction (ANR) headset, or no HPD at all (only in 85 dBA noise). Results revealed statistically significant between-HPD differences in red noise (from 2.3 to 3.1 dB) and in the 100-dBA noise level (from 2.6 to 4.3 dB). An additional finding, which corroborates other studies using different protocols, was that masked thresholds in 85-dBA noise were significantly lower (from 3.2 to 4.4 dB) for the occluded conditions (wearing an HPD) than for the open-ear (unoccluded) condition. This result refutes the belief among many normal-hearing workers that the use of HPDs in relatively low levels of noise compromises their ability to hear necessary workplace sounds. Actual or potential applications of this research include (a) the selection of appropriate HPDs for low-frequency-biased noise exposures wherein signal detection is important and (b) gaining insight into the appropriateness of ANR-based HPDs for certain industrial noise environments.
Occupational noise-induced hearing loss in Indian steel industry workers: an exploratory study.
Singh, Lakhwinder Pal; Bhardwaj, Arvind; Deepak, Kishore Kumar
2013-04-01
The present study focused on exploring the current level of hearing protection and subsequently determined the prevalence of occupational noise-induced hearing loss among casting and forging industry workers. The casting and forging industry provides employment to a significant portion of the population. The level of hearing protection was assessed through questionnaire survey of 572 workers. Out of these workers, 165 and another control group of 57 participants were assessed by formal audiometry. Audiometric tests were conducted at frequencies of 1.0 KHz to 8.0 KHz.The occurrence of hearing loss was determined on the basis of a hearing threshold level with a low fence of 25 dB. Student's test and ANOVA were used to compare the various groups; a p value < .05 was considered statistically significant. More than 90% of the workers sampled showed significant hearing loss at medium and high frequencies. The analyses revealed a higher prevalence of significant hearing loss among the forging workers compared with the workers associated with the other activities. The workers of the Indian steel industry are highly exposed to occupational noise. The majority of workers are not protected from noise-induced hearing loss. There is a need to provide special ear protectors for workers engaged in forging. A complete hearing protection program, including training, audiometry, job rotation, and the use of hearing protection devices, needs to be introduced.
Sound localization with communications headsets: comparison of passive and active systems.
Abel, Sharon M; Tsang, Suzanne; Boyne, Stephen
2007-01-01
Studies have demonstrated that conventional hearing protectors interfere with sound localization. This research examines possible benefits from advanced communications devices. Horizontal plane sound localization was compared in normal-hearing males with the ears unoccluded and fitted with Peltor H10A passive attenuation earmuffs, Racal Slimgard II communications muffs in active noise reduction (ANR) and talk-through-circuitry (TTC) modes and Nacre QUIETPRO TM communications earplugs in off (passive attenuation) and push-to-talk (PTT) modes. Localization was assessed using an array of eight loudspeakers, two in each spatial quadrant. The stimulus was 75 dB SPL, 300-ms broadband noise. One block of 120 forced-choice loudspeaker identification trials was presented in each condition. Subjects responded using a laptop response box with a set of eight microswitches in the same configuration as the speaker array. A repeated measures ANOVA was applied to the dataset. The results reveal that the overall percent correct response was highest in the unoccluded condition (94%). A significant reduction of 24% was observed for the communications devices in TTC and PTT modes and a reduction of 49% for the passive muff and plug and muff with ANR. Disruption in performance was due to an increase in front-back reversal errors for mirror image spatial positions. The results support the conclusion that communications devices with advanced technologies are less detrimental to directional hearing than conventional, passive, limited amplification and ANR devices.
The ac power line protection for an IEEE 587 Class B environment
NASA Technical Reports Server (NTRS)
Roehr, W. D.; Clark, O. M.
1984-01-01
The 587B series of protectors are unique, low clamping voltage transient suppressors to protect ac-powered equipment from the 6000V peak open-circuit voltage and 3000A short circuit current as defined in IEEE standard 587 for Category B transients. The devices, which incorporate multiple-stage solid-state protector components, were specifically designed to operate under multiple exposures to maximum threat levels in this severe environment. The output voltage peaks are limited to 350V under maximum threat conditions for a 120V ac power line, thus providing adequate protection to vulnerable electronic equipment. The principle of operation and test performance data is discussed.
Device for isolation of seed crystals during processing of solution
Montgomery, Kenneth E.; Zaitseva, Natalia P.; Deyoreo, James J.; Vital, Russell L.
1999-01-01
A device for isolation of see crystals during processing of solutions. The device enables a seed crystal to be introduced into the solution without exposing the solution to contaminants or to sources of drying and cooling. The device constitutes a seed protector which allows the seed to be present in the growth solution during filtration and overheating operations while at the same time preventing the seed from being dissolved by the under saturated solution. When the solution processing has been completed and the solution cooled to near the saturation point, the seed protector is opened, exposing the seed to the solution and allowing growth to begin.
Rankin, R.A.; Kotter, D.K.
1997-05-13
The Hall-Effect Arc Protector is used to protect sensitive electronics from high energy arcs. The apparatus detects arcs by monitoring an electrical conductor, of the instrument, for changes in the electromagnetic field surrounding the conductor which would be indicative of a possible arcing condition. When the magnitude of the monitored electromagnetic field exceeds a predetermined threshold, the potential for an instrument damaging are exists and the control system logic activates a high speed circuit breaker. The activation of the breaker shunts the energy imparted to the input signal through a dummy load to the ground. After the arc condition is terminated, the normal signal path is restored. 2 figs.
Rankin, Richard A.; Kotter, Dale K.
1997-01-01
The Hall-Effect Arc Protector is used to protect sensitive electronics from high energy arcs. The apparatus detects arcs by monitoring an electrical conductor, of the instrument, for changes in the electromagnetic field surrounding the conductor which would be indicative of a possible arcing condition. When the magnitude of the monitored electromagnetic field exceeds a predetermined threshold, the potential for an instrument damaging are exists and the control system logic activates a high speed circuit breaker. The activation of the breaker shunts the energy imparted to the input signal through a dummy load to the ground. After the arc condition is terminated, the normal signal path is restored.
NASA Astrophysics Data System (ADS)
Salcedo Ulerio, Reynaldo Odalis
The analysis of overvoltages in electrical distribution networks is of considerable significance since they may damage the power system infrastructure and the associated electrical equipment. Overvoltages in distribution networks arise due to switching transients, resonance, lightning strikes and ground faults, among other causes. The operation of network protectors (NWP), low voltage circuit breakers with directional power relay, in a secondary network prevents the continuous flow of reverse power. There are three modes of operation for the network protectors: sensitive, time delayed, and insensitive. In case of a fault, although all of the network protectors sense the fault at the same time, their operation is not simultaneous. Many of them open very quickly with opening times similar to those of the feeder breaker. However, some operate a few cycles later, others take several seconds to open and a few might even fail to operate. Therefore, depending on the settings of the network protectors, faults can last for significantly long time due to backfeeding of current from the low voltage (LV) network into the medium voltage (MV) network. In this work, low voltages are defined as 208V/460V and medium voltage are defined as 25kV/35kV. This thesis presents overvoltages which arise because of the occurrence of a single-line-to-ground (SLG) fault on the MV side (connected in delta) of the system. The thesis reveals that overvoltage stresses are imposed on insulation, micro-processor controlled equipment, and switching devices by overvoltages during current backfeeding. Also, it establishes a relationship between overvoltage magnitude, its duration, and the network loading conditions. Overvoltages above 3 p.u. may be developed as a result of a simultaneous occurrence of three phenomena: neutral displacement, Ferranti effect, and magnetic current chopping. Furthermore, this thesis exposes the possibility of occurrence of the ferro-resonance phenomena in a distribution network having secondary grid, making the study of extreme importance especially in the case of a misoperating network protector. The test systems for both studies were designed following the conventional distribution network with secondary grid, similar to those in the New York City Area. Simulations were performed using the electro-magnetic transient program revised version (EMTP-RV) considering detailed representation of system components as well as the non-linear magnetization and losses of transformers.
Device for isolation of seed crystals during processing of solution
Montgomery, K.E.; Zaitseva, N.P.; Deyoreo, J.J.; Vital, R.L.
1999-05-18
A device is described for isolation of seed crystals during processing of solutions. The device enables a seed crystal to be introduced into the solution without exposing the solution to contaminants or to sources of drying and cooling. The device constitutes a seed protector which allows the seed to be present in the growth solution during filtration and overheating operations while at the same time preventing the seed from being dissolved by the under saturated solution. When the solution processing has been completed and the solution cooled to near the saturation point, the seed protector is opened, exposing the seed to the solution and allowing growth to begin. 3 figs.
Chefetz, Richard A
2017-01-01
The identified "problem self-state" in a dissociative disorder consultation is like the identified patient in a family therapy; the one who is identified may have an assigned role to be blamed which serves the function of deflecting the activities of painful self-states in other family members. In consultation, the "family" includes the therapist in addition to the patient. When the state identified as a problem self-state is an abuser/protector self-state, complications often involve the profound nature of transference-countertransference enactments between patient and therapist, the delusion of separateness, chronic and acute threats of suicide, negative therapeutic reactions, and the evocation of intense negativity. They also involve affect phobia in both patient and therapist, and the emergence of intense shame in the clinical dyad amongst additional potential burdens in these complicated treatments. The task of the consultant is to protect both patient and therapist from an untoward outcome while relieving the painful burdens entailed by the treatment. The typical core dynamic of the abuser/protector state is as a repository for shame/humiliation welded to anger/rage. This dynamic, and others, must be understood in order to resolve these impasses and create useful movement toward growth in both patient and therapist.
NASA Astrophysics Data System (ADS)
Žumer, Marko; Zajec, Bojan; Rozman, Robert; Nemanič, Vincenc
2012-04-01
Gas-discharge tube (GDT) surge protectors are known for many decades as passive units used in low-voltage telecom networks for protection of electrical components from transient over-voltages (discharging) such as lightning. Unreliability of the mean turn-on DC breakdown voltage and the run-to-run variability has been overcome successfully in the past by adding, for example, a radioactive source inside the tube. Radioisotopes provide a constant low level of free electrons, which trigger the breakdown. In the last decades, any concept using environmentally harmful compounds is not acceptable anymore and new solutions were searched. In our application, a cold field electron emitter source is used as the trigger for the gas discharge but with no activating compound on the two main electrodes. The patent literature describes in details the implementation of the so-called trigger wires (auxiliary electrodes) made of graphite, placed in between the two main electrodes, but no physical explanation has been given yet. We present experimental results, which show that stable cold field electron emission current in the high vacuum range originating from the nano-structured edge of the graphite layer is well correlated to the stable breakdown voltage of the GDT surge protector filled with a mixture of clean gases.
López-Jornet, P; Camacho-Alonso, F; Andujar-Mateos, P
2011-04-01
To apply a tongue protector with habit-modifying therapy through self-control, in the patients with burning mouth syndrome (BMS). A prospective, randomized study was made of 65 consecutive patients with BMS. Fifty subjects were randomized to two groups: group A (informed) and group B (informed and the application of a tongue protector). The symptoms were evaluated by VAS, whereas the psychological profile was assessed using the HAD, with application of the quality of life questionnaires SF-36 and OHIP-49. The duration of treatment was 2 months. Fifty patients (46 females and 4 males) completed the study. The VAS scores in group B were 8.2 at baseline and 4.5 after 2 months. The respective scores in group A were 7.1 and 5.6 - the differences between the two groups being significant (P < 0.001). In group B the OHIP-49 yielded lower scores for most of the scales, with significant differences vs group A. In group B the SF 36 yielded significant differences vs group A in physical role, bodily pain, general health and emotional role. Parafunctional traumatism of the tongue should be taken into account in the pathogenesis of BMS with a view to exploring new therapeutic options. © 2010 John Wiley & Sons A/S.
A, Deepti; Jeevarathan, J; Muthu, Ms; Prabhu V, Rathna; Chamundeswari
2008-09-01
The aim of this study was to estimate the count of Streptococcus mutans in saliva of caries free children using Dentocult SM strip mutans and to evaluate the effect of fluoride varnish on the Streptococcus mutans count in saliva of these caries free children. Thirty caries free children were selected for the study based on the information obtained from a questionnaire prepared. They were randomly assigned into the control group and the study group consisting of ten and twenty children respectively. Samples of saliva were collected using the saliva strips from the Dentocult SM kit and after incubation the presence of the Streptococcus mutans was evaluated using the manufacturers' chart. The study group was subjected to Fluor Protector fluoride varnish application after 24 hours following which the samples were collected again. The average Streptococcus mutans count in primary dentition of caries free children was in the range of 10(4) to 10(5) colony forming units/ml. The average Streptococcus mutans count in primary dentition of caries free children after Fluor Protector fluoride varnish application was below 10(4) colony forming units/ml. Fluor Protector fluoride varnish application showed a statistically significant reduction in the Streptococcus mutans count in saliva of the caries free children in the study group.
... can stop now! 9 Another protector is the Phagocyte (Phag-o-cyte). Phagocytes kill germs by eating them! They also send signals to other Phagocytes Calling all Phagocytes! Calling all Phagocytes! Help! Help! ...
Communication in a noisy environment: Perception of one's own voice and speech enhancement
NASA Astrophysics Data System (ADS)
Le Cocq, Cecile
Workers in noisy industrial environments are often confronted to communication problems. Lost of workers complain about not being able to communicate easily with their coworkers when they wear hearing protectors. In consequence, they tend to remove their protectors, which expose them to the risk of hearing loss. In fact this communication problem is a double one: first the hearing protectors modify one's own voice perception; second they interfere with understanding speech from others. This double problem is examined in this thesis. When wearing hearing protectors, the modification of one's own voice perception is partly due to the occlusion effect which is produced when an earplug is inserted in the car canal. This occlusion effect has two main consequences: first the physiological noises in low frequencies are better perceived, second the perception of one's own voice is modified. In order to have a better understanding of this phenomenon, the literature results are analyzed systematically, and a new method to quantify the occlusion effect is developed. Instead of stimulating the skull with a bone vibrator or asking the subject to speak as is usually done in the literature, it has been decided to excite the buccal cavity with an acoustic wave. The experiment has been designed in such a way that the acoustic wave which excites the buccal cavity does not excite the external car or the rest of the body directly. The measurement of the hearing threshold in open and occluded car has been used to quantify the subjective occlusion effect for an acoustic wave in the buccal cavity. These experimental results as well as those reported in the literature have lead to a better understanding of the occlusion effect and an evaluation of the role of each internal path from the acoustic source to the internal car. The speech intelligibility from others is altered by both the high sound levels of noisy industrial environments and the speech signal attenuation due to hearing protectors. A possible solution to this problem is to denoise the speech signal and transmit it under the hearing protector. Lots of denoising techniques are available and are often used for denoising speech in telecommunication. In the framework of this thesis, denoising by wavelet thresholding is considered. A first study on "classical" wavelet denoising technics is conducted in order to evaluate their performance in noisy industrial environments. The tested speech signals are altered by industrial noises according to a wide range of signal to noise ratios. The speech denoised signals are evaluated with four criteria. A large database is obtained and analyzed with a selection algorithm which has been designed for this purpose. This first study has lead to the identification of the influence from the different parameters of the wavelet denoising method on its quality and has identified the "classical" method which has given the best performances in terms of denoising quality. This first study has also generated ideas for designing a new thresholding rule suitable for speech wavelet denoising in an industrial noisy environment. In a second study, this new thresholding rule is presented and evaluated. Its performances are better than the "classical" method found in the first study when the signal to noise ratio from the speech signal is between --10 dB and 15 dB.
40 CFR 211.210-1 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... this regulation: (1) Must be labeled at the point of ultimate purchase or distribution to the...) Manufacturers who distribute protectors in commerce to another manufacturer for packaging for ultimate purchase...
Protocol of a randomized controlled trial of hearing protection interventions for farm operators.
McCullagh, Marjorie C; Ronis, David L
2015-04-18
Hearing loss and tinnitus are prevalent in America, and noise-induced hearing loss is a leading cause of hearing loss. Noise-induced hearing loss has negative impact on quality of life, physical and emotional functioning, social life, and employment. In addition, noise-induced hearing loss results in heavy social and economic burdens on families and communities from all ethnic and socioeconomic groups. Farmers are a group that is particularly high risk for noise-induced hearing loss, and is underserved by programs designed to limit that risk. They are among the most noise-exposed group of workers, and experience the second highest prevalence of noise-induced hearing loss among all occupational categories. In agriculture, 1.5 million workers (43.3%) report exposure to hazardous noise. Although use of hearing protection devices (HPDs) would protect them from noise-induced hearing loss, use among farmers is low. The purpose of this project is to compare the effectiveness of several approaches to influencing hearing protector use. Approaches include: a) an interactive, predictors-based intervention delivered via the Internet; b) a static informational web site; and c) a mailed sampler of hearing protectors. The goals are to further develop an intervention to promote farmers' use of HPDs, and compare the effectiveness of the interventions delivered in various combinations. Participants will include 701 farmers. Sites will be affiliates of a major farmer organization. Data will be collected at baseline, 6, and 12 months. A random intercept mixed model will be used to explore the fixed effects of the three NIHL prevention interventions over time while adjusting for age and gender. This project will involve a partnership between the University of Michigan and a major farmer organization to accomplish project aims. Results of this study will be used to inform future research-to-practice studies to increase hearing protector use. Increased use of hearing protectors is expected to reduce rates of noise-induced hearing loss and other negative effects of high noise exposure, and improve quality of life in this high-risk and underserved group. Clinicaltrials.gov NCT01454895 Registered 14 October, 2011.
Effectiveness of Ear Splint Therapy for Ear Deformities
2017-01-01
Objective To present our experience with ear splint therapy for babies with ear deformities, and thereby demonstrate that this therapy is an effective and safe intervention without significant complications. Methods This was a retrospective study of 54 babies (35 boys and 19 girls; 80 ears; age ≤3 months) with ear deformities who had received ear splint therapy at the Center for Torticollis, Department of Physical Medicine and Rehabilitation, Ajou University Hospital between December 2014 and February 2016. Before the initiation of ear splint therapy, ear deformities were classified with reference to the standard terminology. We compared the severity of ear deformity before and after ear splint therapy by using the physician's ratings. We also compared the physician's ratings and the caregiver's ratings on completion of ear splint therapy. Results Among these 54 babies, 41 children (58 ears, 72.5%) completed the ear splint therapy. The mean age at initiation of therapy was 52.91±18.26 days and the treatment duration was 44.27±32.06 days. Satyr ear, forward-facing ear lobe, Darwinian notch, overfolded ear, and cupped ear were the five most common ear deformities. At the completion of therapy, the final physician's ratings of ear deformities were significantly improved compared to the initial ratings (8.28±1.44 vs. 2.51±0.92; p<0.001). There was no significant difference between the physician's ratings and the caregiver's ratings at the completion of ear splint therapy (8.28±1.44 vs. 8.0±1.61; p=0.297). Conclusion We demonstrated that ear splint therapy significantly improved ear deformities in babies, as measured by quantitative rating scales. Ear splint therapy is an effective and safe intervention for babies with ear deformities. PMID:28289646
33 CFR 150.611 - What head protection is required?
Code of Federal Regulations, 2010 CFR
2010-07-01
... of injury from falling objects or contact with electrical conductors, personnel working or visiting such an area wear head protectors designed to protect them against such injury and complying with 29...
[Radiation Anticarcinogenesis by Thiazolidine Pro-drug
NASA Technical Reports Server (NTRS)
Warters, Raymond L.; Roberts, Jeanette C.; Fain, Heidi
1999-01-01
The original goal of this work was to determine the capacity of selected aminothiols to modulate radiation induced cytotoxicity, mutagenesis and carcinogenesis in a human mammary epithelial cell line. The conclusions from this work are that WR-1065 is the "gold standard" for protection against radiation induced cytotoxicity, mutagenesis and carcinogenesis. While a potent radiation protector, WR-1065 is cytotoxic in vitro and in vivo. Our rationale for a study of the thiazolidine pro-drugs was that these compounds are neither toxic in vitro or in vivo. The results obtained during this funding period indicate that the thiazolidine pro-drugs are as potent as WR-1065 as protectors against radiation induced mutation induction, and thus presumably against radiation induced carcinogenesis. Our results indicate that the thiazolidine prodrugs are excellent candidates to test as non-toxic anticarcinogens for protecting astronauts from cancer induction during space travel.
Lazor-Blanchet, Catherine; Rusca, Sophie; Vernez, David; Berry, Raymond; Albrecht, Eric; Droz, Pierre-Olivier; Boillat, Marcel-André
2004-05-01
Waterproofing agents are widely applied to leather and textile garments; they are also used as floor stain protectors by professionals. Acute respiratory injury is described in three cases of young healthy adults following occupational inhalation of a new waterproofing formulation containing an acrylate fluoropolymer. Within 1 or 2 h after exposure they developed a rapidly progressive dyspnoea; two of them had hypoxaemia and flu-like reactions. All patients improved with supportive treatment in a few days. The mechanism of toxicity is still under investigation, but experimental data suggest the role of this new acrylate fluoropolymer. Tilers should be warned against spraying floor stain repellents; there is also a need to make consumers aware that the spraying of waterproofing agents in a closed environment and concomitant smoking should be avoided.
Permissive beliefs and attitudes about older adult suicide: a suicide enabling script?
Winterrowd, Erin; Canetto, Silvia Sara; Benoit, Kathrin
2017-02-01
In the United States, suicide rates are highest among European American older adults. This phenomenon calls attention to cultural factors, specifically, the suicide beliefs and attitudes of European Americans. Beliefs and attitudes matter in the vulnerability to suicide. As predicted by cultural scripts of suicide theory, suicide is most likely among individuals and in communities where it is expected and is most acceptable. This study examined beliefs about the precipitants of, and protectors against older adult suicide, as well as suicide attitudes, in a predominantly European American community. Two hundred and fifty-five older adults (86% European American) and 281 younger adults (81% European American) indicated what they thought were the most likely older adult suicide precipitants and protectors, and their opinion about older adult suicide, depending on precipitant. Health problems were the most endorsed older adult suicide precipitants. Suicide precipitated by health problems was also rated most positively (e.g., rational, courageous). Older adults, persons with more education, and persons who did not identify with a religion expressed the most favorable attitudes about older adult suicide, across suicide precipitants. Men viewed older adult suicide as more admissible, and women, with more sympathy. Perceived suicide protectors included religiosity among older adults, and supportive relationships among younger adults. The belief, in this study's predominantly European American community, that older adult suicide is triggered by health problems, together with favorable attitudes about older adult suicide, suggest an enabling older adult suicide script, with implications for suicide risk and prevention.
Gender differences in use of hearing protection devices among farm operators.
McCullagh, Marjorie C; Banerjee, Tanima; Yang, James J; Bernick, Janice; Duffy, Sonia; Redman, Richard
2016-01-01
Although farm operators have frequent exposure to hazardous noise and high rates of noise-induced hearing loss, they have low use of hearing protection devices (HPDs). Women represent about one-third of farm operators, and their numbers are climbing. However, among published studies examining use of HPDs in this worker group, none have examined gender-related differences. The purpose of this study was to examine gender-related differences in use of hearing protection and related predictors among farm operators. Data previously collected at farm shows and by telephone were analyzed using t-tests and generalized linear model with zero inflated negative binomial (ZINB) distribution. The difference in rate of hearing protector use between men and women farm operators was not significant. There was no difference between men and women in most hearing protector-related attitudes and beliefs. Although men and women farm operators had similar rates of use of hearing protectors when working in high-noise environments, attitudes about HPD use differed. Specifically, interpersonal role modeling was a predictor of HPD use among women, but not for men. This difference suggests that while farm operators of both genders may benefit from interventions designed to reduce barriers to HPD use (e.g., difficulty communicating with co-workers and hearing warning sounds), farm women have unique needs in relation to cognitive-perceptual factors that predict HPD use. Women farm operators may lack role models for use of HPDs (e.g., in peers and advertising), contributing to their less frequent use of protection.
Chemical modification of normal tissue damage induced by photodynamic therapy.
Sigdestad, C. P.; Fingar, V. H.; Wieman, T. J.; Lindberg, R. D.
1996-01-01
One of the limitations of successful use of photodynamic therapy (PDT) employing porphyrins is the acute and long-term cutaneous photosensitivity. This paper describes results of experiments designed to test the effects of two radiation protective agents (WR-2721, 500 mg kg-1 or WR-3689, 700 mg kg-1) on murine skin damage induced by PDT. C3H mice were shaved and depilated three days prior to injection with the photosensitiser, Photofrin (5 or 10 mg kg-1). Twenty-four hours later, the mice were injected intraperitoneally with a protector 30 min prior to Argon dye laser (630 nm) exposure. The skin response was followed for two weeks post irradiation using an arbitrary response scale. A light dose response as well as a drug dose response was obtained. The results indicate that both protectors reduced the skin response to PDT, however WR-2721 was demonstrated to be the most effective. The effect of the protectors on vascular stasis after PDT was determined using a fluorescein dye exclusion assay. In mice treated with Photofrin (5 mg kg-1), and 630 nm light (180 J cm-2) pretreatment with either WR-2721 or WR-3689 resulted in significant protection of the vascular effects of PDT. These studies document the ability of the phosphorothioate class of radiation protective agents to reduce the effects of light on photosensitized skin. They do so in a drug dose-dependent fashion with maximum protection at the highest drug doses. PMID:8763855
Daniali, Lily N; Rezzadeh, Kameron; Shell, Cheryl; Trovato, Matthew; Ha, Richard; Byrd, H Steve
2017-03-01
A single practice's treatment protocol and outcomes following molding therapy on newborn ear deformations and malformations with the EarWell Infant Ear Correction System were reviewed. A classification system for grading the severity of constricted ear malformations was created on the basis of anatomical findings. A retrospective chart/photograph review of a consecutive series of infants treated with the EarWell System from 2011 to 2014 was undertaken. The infants were placed in either deformation or malformation groups. Three classes of malformation were identified. Data regarding treatment induction, duration of treatment, and quality of outcome were collected for all study patients. One hundred seventy-five infant ear malformations and 303 infant ear deformities were treated with the EarWell System. The average age at initiation of treatment was 12 days; the mean duration of treatment was 37 days. An average of six office visits was required. Treated malformations included constricted ears [172 ears (98 percent)] and cryptotia [three ears (2 percent)]. Cup ear (34 ears) was considered a constricted malformation, in contrast to the prominent ear deformity. Constricted ears were assigned to one of three classes, with each subsequent class indicating increasing severity: class I, 77 ears (45 percent); class II, 81 ears (47 percent); and class III, 14 ears (8 percent). Molding therapy with the EarWell System reduced the severity by an average of 1.2 points (p < 0.01). Complications included minor superficial excoriations and abrasions. The EarWell System was shown to be effective in eliminating or reducing the need for surgery in all but the most severe malformations. Therapeutic, IV.
3D finite element model of the chinchilla ear for characterizing middle ear functions
Wang, Xuelin; Gan, Rong Z.
2016-01-01
Chinchilla is a commonly used animal model for research of sound transmission through the ear. Experimental measurements of the middle ear transfer function in chinchillas have shown that the middle ear cavity greatly affects the tympanic membrane (TM) and stapes footplate (FP) displacements. However, there is no finite element (FE) model of the chinchilla ear available in the literature to characterize the middle ear functions with the anatomical features of the chinchilla ear. This paper reports a recently completed 3D FE model of the chinchilla ear based on X-ray micro-computed tomography images of a chinchilla bulla. The model consisted of the ear canal, TM, middle ear ossicles and suspensory ligaments, and the middle ear cavity. Two boundary conditions of the middle ear cavity wall were simulated in the model as the rigid structure and the partially flexible surface, and the acoustic-mechanical coupled analysis was conducted with these two conditions to characterize the middle ear function. The model results were compared with experimental measurements reported in the literature including the TM and FP displacements and the middle ear input admittance in chinchilla ear. An application of this model was presented to identify the acoustic role of the middle ear septa - a unique feature of chinchilla middle ear cavity. This study provides the first 3D FE model of the chinchilla ear for characterizing the middle ear functions through the acoustic-mechanical coupled FE analysis. PMID:26785845
Scheinpflug, L; Vorwerk, U; Begall, K
1995-01-01
By means of a model of the external and the middle ear it is possible to simulate various, exactly defined pathological conditions of the middle ear and to describe their influence on ear canal resonance. Starting point of the investigations are fresh postmortem preparations of 8 human temporal bones with an intact ear drum and a retained skin of the ear canal. The compliance of the middle ear does not significantly differ from the clinical data of probands with healthy ears. After antrotomy it is possible to simulate pathological conditions of the middle ear one after the other at the same temporal bone. The influence of the changed middle ear conditions on ear drum compliance, ear canal volume and on the resonance curve of the external ear canal was investigated. For example, the middle ear was filled with water to create approximately the same conditions as in acute serous otitis media. In this middle ear condition a significant increase of the sound pressure amplification was found, on an average by 4 decibels compared to the unchanged temporal bone model. A small increase in resonance frequency was also measured. The advantages of this model are the approximately physiological conditions and the constant dimensions of the external and middle ear.
19 CFR 134.45 - Approved markings of country name.
Code of Federal Regulations, 2011 CFR
2011-04-01
... “Brasil” for “Brazil” and “Italie” for “Italy,” are acceptable. (c) Adjectival form. The adjectival form... “Brazil nuts” are unacceptable. (d) Colonies, possessions, or protectorates. The name of a colony...
19 CFR 134.45 - Approved markings of country name.
Code of Federal Regulations, 2014 CFR
2014-04-01
... “Brasil” for “Brazil” and “Italie” for “Italy,” are acceptable. (c) Adjectival form. The adjectival form... “Brazil nuts” are unacceptable. (d) Colonies, possessions, or protectorates. The name of a colony...
19 CFR 134.45 - Approved markings of country name.
Code of Federal Regulations, 2013 CFR
2013-04-01
... “Brasil” for “Brazil” and “Italie” for “Italy,” are acceptable. (c) Adjectival form. The adjectival form... “Brazil nuts” are unacceptable. (d) Colonies, possessions, or protectorates. The name of a colony...
19 CFR 134.45 - Approved markings of country name.
Code of Federal Regulations, 2012 CFR
2012-04-01
... “Brasil” for “Brazil” and “Italie” for “Italy,” are acceptable. (c) Adjectival form. The adjectival form... “Brazil nuts” are unacceptable. (d) Colonies, possessions, or protectorates. The name of a colony...
Overload-protector/fault-indicator circuit
NASA Technical Reports Server (NTRS)
Paluka, J. R.; Moore, S. F.
1977-01-01
Circuit incorporates three-terminal current limiter (78M24) to increase overall reliability and to eliminate transistor burnouts resulting from shorted interconnection lines and other overloads. Fact-acting light emitting diodes across the limiters show status of transistor output circuits.
2015-12-22
Part of the southern hemisphere on dwarf planet Ceres is seen in this image taken by NASA Dawn spacecraft. Hamori crater, named after a Japanese god and protector of tree leaves, is the large crater near the center of the image.
21 CFR 878.4370 - Surgical drape and drape accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... site of surgical incision from microbial and other contamination. The device includes a plastic wound protector that may adhere to the skin around a surgical incision or be placed in a wound to cover its...
Method of Making Lightweight, Single Crystal Mirror
NASA Technical Reports Server (NTRS)
Bly, Vincent T. (Inventor)
2015-01-01
A method of making a mirror from a single crystal blank may include fine grinding top and bottom surfaces of the blank to be parallel. The blank may then be heat treated to near its melting temperature. An optical surface may be created on an optical side of the blank. A protector may be bonded to the optical surface. With the protector in place, the blank may be light weighted by grinding a non-optical surface of the blank using computer controlled grinding. The light weighting may include creating a structure having a substantially minimum mass necessary to maintain distortion of the mirror within a preset limit. A damaged layer of the non-optical surface caused by light weighting may be removed with an isotropic etch and/or repaired by heat treatment. If an oxide layer is present, the entire blank may then be etched using, for example, hydrofluoric acid. A reflecting coating may be deposited on the optical surface.
Framing tobacco control efforts within an ethical context
Fox, B
2005-01-01
Public health efforts to promote tobacco control are not performed within a vacuum. They are subject to interpretation and misinterpretation by consumers and policymakers based largely upon the initial framing of the issues. This paper notes how the tobacco industry has established a particular frame that it is the protector of individual rights and that the public health community is trying to eliminate those rights. This paper then shows how the public health community uses metaphors that may unintentionally support this framing and suggests that by reframing public health efforts in accordance with core ethical principles, the public health community can create more positive messages. A public health ethical framework is proposed to examine how the application of the principles can influence the tobacco control movement. Through the increased use of ethics in tobacco control, the public health community may be better positioned to claim the high road as the protector of the public's interests. PMID:16046701
Ear molding in newborn infants with auricular deformities.
Byrd, H Steve; Langevin, Claude-Jean; Ghidoni, Lorraine A
2010-10-01
A review of a single physician's experience in managing over 831 infant ear deformities (488 patients) is presented. The authors' methods of molding have advanced from the use of various tapes, glues, and stents, to a comprehensive yet simple system that shapes the antihelix, the triangular fossa, the helical rim, and the overly prominent conchal-mastoid angle (EarWell Infant Ear Correction System). The types of deformities managed, and their relative occurrence, are as follows: (1) prominent/cup ear, 373 ears (45 percent); (2) lidding/lop ear, 224 ears (27 percent); (3) mixed ear deformities, 83 ears (10 percent) (all had associated conchal crus); (4) Stahl's ear, 66 ears (8 percent); (5) helical rim abnormalities, 58 ears (7 percent); (6) conchal crus, 25 ears (3 percent); and (7) cryptotia, two ears (0.2 percent). Bilateral deformities were present in 340 patients (70 percent), with unilateral deformities in 148 patients (30 percent). Fifty-eight infant ears (34 patients) were treated using the final version of the EarWell Infant Ear Correction System with a success rate exceeding 90 percent (good to excellent results). The system was found to be most successful when begun in the first week of the infant's life. When molding was initiated after 3 weeks from birth, only approximately half of the infants had a good response. Congenital ear deformities are common and only approximately 30 percent self-correct. These deformities can be corrected by initiating appropriate molding in the first week of life. Neonatal molding reduces the need for surgical correction with results that often exceed what can be achieved with the surgical alternative.
Brungart, Douglas S; Simpson, Brian D
2007-09-01
Similarity between the target and masking voices is known to have a strong influence on performance in monaural and binaural selective attention tasks, but little is known about the role it might play in dichotic listening tasks with a target signal and one masking voice in the one ear and a second independent masking voice in the opposite ear. This experiment examined performance in a dichotic listening task with a target talker in one ear and same-talker, same-sex, or different-sex maskers in both the target and the unattended ears. The results indicate that listeners were most susceptible to across-ear interference with a different-sex within-ear masker and least susceptible with a same-talker within-ear masker, suggesting that the amount of across-ear interference cannot be predicted from the difficulty of selectively attending to the within-ear masking voice. The results also show that the amount of across-ear interference consistently increases when the across-ear masking voice is more similar to the target speech than the within-ear masking voice is, but that no corresponding decline in across-ear interference occurs when the across-ear voice is less similar to the target than the within-ear voice. These results are consistent with an "integrated strategy" model of speech perception where the listener chooses a segregation strategy based on the characteristics of the masker present in the target ear and the amount of across-ear interference is determined by the extent to which this strategy can also effectively be used to suppress the masker in the unattended ear.
Ear infection; Infection - ear ... of the ear. The condition can be: Acute ear infection. Starts suddenly and lasts for a short period of time. It is often painful. Chronic ear infection. Occurs when the ear infection does not go ...
Huang, Lihui; Han, Demin; Guo, Ying; Liu, Sha; Cui, Xiaoyan; Mo, Lingyan; Qi, Beier; Cai, Zhenghua; Liu, Hui; En, Hui; Guo, Liansheng
2008-10-01
Audiological characteristics were investigated in 81 ears of 53 infants with abnormal transient evoked otoacoustic emission (TEOAE) and normal auditory brainstem response (ABR). The relationship between ABR and other hearing testing methods, including 40Hz auditory event-related potential (40Hz-AERP), auditory steady state response (ASSR), distortion product otoacoustic emission (DPOAE), tympanometry, and acoustic reflex, was analyzed. Of the 81 ears, 18 ears (22.2%) were normal, while 63 ears (77.8%) were abnormal according to the tests. Testing of the 40 Hz AERP (36 ears) and ASSR (45 ears) revealed that 14 ears (38.9%) and 27 ears (60.0%) were abnormal, respectively. Testing of DPOAE in 68 ears revealed that 50 ears (73.5%) were abnormal. Testing of tympanometry in 50 ears and acoustic reflex in 47 ears revealed that 9 ears (18%) and 27 ears (57.4%) were abnormal, respectively. The present data suggests that the hearing of infants cannot be sufficiently evaluated with ABR only and that it must be evaluated with integrative audiological testing methods.
Middle ear impedance measurements in large vestibular aqueduct syndrome.
Bilgen, Cem; Kirkim, Günay; Kirazli, Tayfun
2009-06-01
To assess the effect of inner ear pressure on middle ear impedance in patients with large vestibular aqueduct syndrome (LVAS). Data from admittance tympanometry and multifrequency tympanometry on 8 LVAS patients and control subjects were studied. Static acoustic compliance (SAC) values for the ears with stable sensorineural hearing loss (SNHL) were within the limits of the mean values of control groups except for two ears. The resonance frequency (RF) values of the ears with stable SNHL were lower than the mean values of control groups except for three ears. SAC values for the two ears with fluctuating SNHL were lower and the RF values were higher than the mean values of control groups. Decreased SAC values and increased RF values found in the ears with fluctuating SNHL might be an indirect indicator of increased inner ear pressure, while low RF values in the ears with stable SNHL might reflect the decreased inner ear impedance.
Nonsurgical correction of congenital ear abnormalities in the newborn: Case series.
Smith, Wg; Toye, Jw; Reid, A; Smith, Rw
2005-07-01
To determine whether a simple, nonsurgical treatment for congenital ear abnormalities (lop-ear, Stahl's ear, protruding ear, cryptotia) improved the appearance of ear abnormalities in newborns at six weeks of age. This is a descriptive case series. All newborns with identified abnormalities were referred by their family physician to one paediatrician (WGS) in a small level 2 perinatal centre. The ears were waxed and taped in a standard manner within 10 days of birth. Pictures were taken before taping and at the end of taping (one month). All patients and pictures were assessed by one plastic surgeon (JWT) at six weeks of age and scored using a standard scoring system. A telephone survey of the nontreatment group was conducted. The total number of ears assessed was 90. Of this total, 69 ears were taped and fully evaluated in the study (77%). The refusal rate was 23%. In the treatment group, 59% had lop-ear, 19% had Stahl's ear, 17% had protruding ear and 3% had cryptotia. Overall correction (excellent/improved) for the treatment group was 90% (100% for lop-ear, 100% for Stahl's ear, 67% for protruding ear and 0% for cryptotia). In the nontreatment (refusal) group, 67% of the ears failed to correct spontaneously. No complications were recognized by the authors or parents by six weeks. The percentage of newborns in one year in the perinatal centre with recognized ear abnormalities was 6% (90 of 1600). A simple, nonsurgical treatment in a Caucasian population appeared to be very effective in correcting congenital ear abnormalities with no complications and high patient/parent satisfaction.
Sonographic Measurement of Fetal Ear Length in Turkish Women with a Normal Pregnancy
Özdemir, Mucize Eriç; Uzun, Işıl; Karahasanoğlu, Ayşe; Aygün, Mehmet; Akın, Hale; Yazıcıoğlu, Fehmi
2014-01-01
Background: Abnormal fetal ear length is a feature of chromosomal disorders. Fetal ear length measurement is a simple measurement that can be obtained during ultrasonographic examinations. Aims: To develop a nomogram for fetal ear length measurements in our population and investigate the correlation between fetal ear length, gestational age, and other standard fetal biometric measurements. Study Design: Cohort study. Methods: Ear lengths of the fetuses were measured in normal singleton pregnancies. The relationship between gestational age and fetal ear length in millimetres was analysed by simple linear regression. In addition, the correlation of fetal ear length measurements with biparietal diameter, head circumference, abdominal circumference, and femur length were evaluated.Ear length measurements were obtained from fetuses in 389 normal singleton pregnancies ranging between 16 and 28 weeks of gestation. Results: A nomogram was developed by linear regression analysis of the parameters ear length and gestational age. Fetal ear length (mm) = y = (1.348 X gestational age)−12.265), where gestational ages is in weeks. A high correlation was found between fetal ear length and gestational age, and a significant correlation was also found between fetal ear length and the biparietal diameter (r=0.962; p<0.001). Similar correlations were found between fetal ear length and head circumference, and fetal ear length and femur length. Conclusion: The results of this study provide a nomogram for fetal ear length. The study also demonstrates the relationship between ear length and other biometric measurements. PMID:25667783
46 CFR 111.30-17 - Protection of instrument circuits.
Code of Federal Regulations, 2011 CFR
2011-10-01
... circuit of a current transformer must not be fused, and the circuit from a current transformer to a device that is not in the switchboard must have a high voltage protector to short the transformer during an...
46 CFR 111.30-17 - Protection of instrument circuits.
Code of Federal Regulations, 2014 CFR
2014-10-01
... circuit of a current transformer must not be fused, and the circuit from a current transformer to a device that is not in the switchboard must have a high voltage protector to short the transformer during an...
46 CFR 111.30-17 - Protection of instrument circuits.
Code of Federal Regulations, 2012 CFR
2012-10-01
... circuit of a current transformer must not be fused, and the circuit from a current transformer to a device that is not in the switchboard must have a high voltage protector to short the transformer during an...
46 CFR 111.30-17 - Protection of instrument circuits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... circuit of a current transformer must not be fused, and the circuit from a current transformer to a device that is not in the switchboard must have a high voltage protector to short the transformer during an...
46 CFR 111.30-17 - Protection of instrument circuits.
Code of Federal Regulations, 2013 CFR
2013-10-01
... circuit of a current transformer must not be fused, and the circuit from a current transformer to a device that is not in the switchboard must have a high voltage protector to short the transformer during an...
The effects of V2 antagonist (OPC-31260) on endolymphatic hydrops.
Takeda, Taizo; Sawada, Shoichi; Takeda, Setsuko; Kitano, Hiroya; Suzuki, Mikio; Kakigi, Akinobu; Takeuchi, Shunji
2003-08-01
In the present study, two experiments were performed to investigate the influence of OPC-31260 on experimentally induced endolymphatic hydrops in guinea pigs and the regulation of aquaporin-2 (AQP2) mRNA expression in the rat inner ear. In morphological studies, the increases in the ratios of the length of Reissner's membrane (IR-L) and the cross-sectional area of the scala media (IR-S) were quantitatively assessed among normal guinea pigs (normal ears) and three groups with hydropic ears: hydropic ears with no infusion (non-infusion hydropic ears), hydropic ears with an infusion of physiological saline into the scala tympani (saline-infused hydropic ears) and hydropic ears with infusion of 0.3% OPC-31260 into the scala tympani (OPC-infused hydropic ears). IR-Ls in the experimental groups were markedly larger than in the normal ear group, but there was no significant difference among the groups of non-infusion hydropic ears, saline-infused hydropic ears and OPC-infused hydropic ears. The IR-Ss of non-infusion hydropic ears and saline-infused hydropic ears (48.8-49.3%) were statistically different from that of normal ears (6.5%) (Dunnet multiple comparison test, P<0.01). However, IR-S of the OPC-infused hydropic ears (-14.8%) was significantly smaller than those of non-infusion hydropic ears and saline-infused hydropic ears (one-way ANOVA, P<0.01). In the quantitative polymerase chain reaction study, a comparison of the ratio of AQP2 and beta-actin mRNA (MAQP2/Mbeta-actin) was made between water-injected and OPC-31260-injected rats. An intravenous injection of OPC-31260 resulted in a significant decrease in MAQP2/Mbeta-actin both in the cochlea and in the endolymphatic sac (t-test, P<0.001). These results indicate that water homeostasis in the inner ear is regulated via the vasopressin-AQP2 system, and that the vasopressin type-2 antagonist OPC-31260 is a promising drug in the treatment of Meniere's disease.
Surgical management of polyotia.
Pan, Bo; Qie, Shuyan; Zhao, Yanyong; Tang, Xiaojun; Lin, Lin; Yang, Qinghua; Zhuang, Hongxing; Jiang, Haiyue
2010-08-01
Polyotia is an extremely rare type of congenital external ear malformation, which is defined as an accessory ear that is large enough to resemble an additional pinna. The terms 'mirror ear' or 'accessory ear' are sometime used. We present our methods in correcting this malformation and summarise the aetiology. The posterior part of the polyotia may presents with a normal ear, a constricted ear or a microtic ear. Free auricular composite tissue transplantation was used to correct the constricted ear. Ear reconstruction was applied in cases of microtia. The anterior auricle was mainly used to form the tragus. 7 cases polyotia were treated between 2004 and 2008. After free auricular composite tissue transplantation the size of the constricted ear and the contralateral ear was similar. In microtia cases the reconstructed ears were natural looking and had a satisfactory three-dimensional contour. The extra tissue of the anterior ear was excised and the tragus was reconstructed. Through operative intervention tailored to the individual case natural-looking and symmetric ears were acquired. The aetiology of polyotia probably relates to abnormal migration of neural crest cell. Copyright 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Clearance by the mucociliary system in 'simple chronic otitis media'.
Hadas, E; Sadé, J
1979-08-01
This is a study of the rate of middle ear clearance in chronic otitis media and atelectatic ears. The clearance rate was measured with the aid of non-soluble saccharin, introduced into the middle ear through an existing perforation in 'chronic ears', or through a ventilating tube in atelectatic ears. Cholesteatomatous ears were excluded. Altogether 122 ears were examined and about two-thirds of the subjects felt the sweet taste in their mouths thereafter. The average time it took for the saccharin to be transported from the middle ear to the taste buds was 33' 22" minutes in non-infected (i.e. dry) chronic ears (38 patients or 66 per cent). Wet or infected ears with chronic otitis media (30 patients, or 58 per cent) showed a slower transport rate, averaging 54' 22" minutes--the difference was significant at the 0.01 level. 8 (63 per cent) of the atelectatic ears transported the saccharin at an average rate of 50' 25". This study demonstrated that most ears with 'simple' chronic otitis media and atelectatic ears have a patent eustachian tube and that their mucociliary system can transport foreign particles through it. When the ear is infected, transport tends to be slowed down.
Anomalies of the middle and inner ear.
Rodriguez, Kimsey; Shah, Rahul K; Kenna, Margaret
2007-02-01
The development of the middle and inner ear highlights the intricacy of embryology. As early as 3 weeks after fertilization, the inner ear begins taking form. This process, along with development of the middle ear, continues throughout gestation. At birth, the middle ear, inner ear, and associated structures are almost adult size. An understanding of the embryologic development of the ear serves as a foundation for evaluating and managing congenital malformations of these structures. The focus of this article is the normal, abnormal, and arrested development of the middle and inner ear, with a clinical emphasis on malformed middle and inner ear structures and a discussion of associated syndromes.
75 FR 45670 - Submission for OMB Review: Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-03
... audiograms; training workers on the effects of noise, hearing protectors, and audiometric examinations... the Department of Labor--Occupational Safety and Health Administration (OSHA), Office of Management.... Agency: Occupational Safety and Health Administration. Type of Review: Extension without change of a...
ERIC Educational Resources Information Center
TechTrends, 1992
1992-01-01
Reviews new educational technology products, including a microcomputer-based tutoring system, laser barcode reader, video/data projectors, CD-ROM for notebook computers, a system to increase a printer's power, data cartridge storage shell, knowledge-based decision tool, video illustrator, interactive videodiscs, surge protectors, scanner system,…
Earplug rankings based on the protector-attenuation rating (P-AR).
DOT National Transportation Integrated Search
1975-01-01
Forty-five attenuation spectra for earplugs were classified according to a simplified method designed to produce single-number ratings of noise reduction. The rating procedure was applied to the mean attenuation scores, to mean-minus-one-standard-dev...
Resources for Teachers Starting a Planet Protector’s Club
EPA’s Planet Protector activities are a great way to get student’s interested in reducing, reusing and recycling. Use the activities to launch an ongoing club with our club factsheet, membership badge, activity calendar, and certificate of completion.
Noormohammadpour, Pardis; Rostami, Mohsen; Nourian, Ruhollah; Mansournia, Mohammad Ali; Sarough Farahani, Saeed; Farahbakhsh, Farzin; Kordi, Ramin
2015-06-01
According to anecdotal findings, some wrestling coaches and wrestlers believe that cauliflower ear might lead to hearing loss. Our preliminary study showed that the prevalence of hearing loss reported by the wrestlers with cauliflower ear is significantly higher than this rate among wrestlers without cauliflower ear. To the best of our knowledge, no other study has confirmed this finding employing hearing tests. To evaluate and to compare the prevalence of hearing loss among wrestlers with and without cauliflower ears employing hearing tests. The subjects were randomly selected form 14 wrestling clubs in Tehran. Subjects were 201 wrestlers with cauliflower ears (100 wrestlers with one cauliflower ear and 101 wrestlers with two cauliflower ears) and 139 wrestlers without cauliflower ears. All the participants in this study were interviewed to collect information on demographic factors and medical history of risk factors and diseases related to hearing loss. The subjects in both groups underwent otoscopic and audiologic examinations. Audiometric examination results at the frequency range of 0.5 - 8 KHz showed that the prevalence of hearing loss among cauliflower ears was higher than this rate among non-cauliflower ears. Also, the percentage of positive history of ear infections among cauliflower ears (8.4%) was about two times more than this finding among non-cauliflower ears (4.9%). This difference tended to be significant (OR: 1.86, P = 0.06, 95% CI: 0.98 - 3.53). To the best of our knowledge, this is the first study showing that the prevalence of hearing loss among cauliflower ears is higher than this rate among non-cauliflower ears confirmed by audiological tests. This emphasizes that, more preventive measures such as mandatory ear gear for wrestlers are required.
Noormohammadpour, Pardis; Rostami, Mohsen; Nourian, Ruhollah; Mansournia, Mohammad Ali; Sarough Farahani, Saeed; Farahbakhsh, Farzin; Kordi, Ramin
2015-01-01
Background: According to anecdotal findings, some wrestling coaches and wrestlers believe that cauliflower ear might lead to hearing loss. Our preliminary study showed that the prevalence of hearing loss reported by the wrestlers with cauliflower ear is significantly higher than this rate among wrestlers without cauliflower ear. To the best of our knowledge, no other study has confirmed this finding employing hearing tests. Objectives: To evaluate and to compare the prevalence of hearing loss among wrestlers with and without cauliflower ears employing hearing tests. Patients and Methods: The subjects were randomly selected form 14 wrestling clubs in Tehran. Subjects were 201 wrestlers with cauliflower ears (100 wrestlers with one cauliflower ear and 101 wrestlers with two cauliflower ears) and 139 wrestlers without cauliflower ears. All the participants in this study were interviewed to collect information on demographic factors and medical history of risk factors and diseases related to hearing loss. The subjects in both groups underwent otoscopic and audiologic examinations. Results: Audiometric examination results at the frequency range of 0.5 - 8 KHz showed that the prevalence of hearing loss among cauliflower ears was higher than this rate among non-cauliflower ears. Also, the percentage of positive history of ear infections among cauliflower ears (8.4%) was about two times more than this finding among non-cauliflower ears (4.9%). This difference tended to be significant (OR: 1.86, P = 0.06, 95% CI: 0.98 - 3.53). Conclusions: To the best of our knowledge, this is the first study showing that the prevalence of hearing loss among cauliflower ears is higher than this rate among non-cauliflower ears confirmed by audiological tests. This emphasizes that, more preventive measures such as mandatory ear gear for wrestlers are required. PMID:26448842
Enzymatic recontouring of auricular cartilage in a rabbit model.
Massengill, Phillip L; Goco, Paulino E; Norlund, L Layne; Muir-Padilla, Jeanne
2005-01-01
To evaluate the effectiveness of contouring auricular cartilage in a rabbit model using biologically active enzymes injected subcutaneously. The first phase determined the most effective volume and concentration required to affect the cartilage. To accomplish this task, we used ex vivo rabbit ears from a slaughterhouse. In the second phase, we injected 1 mL of hyaluronidase (150 U per milliliter of isotonic sodium chloride solution [saline]), elastase (1 mg per milliliter of saline), or saline into the ears of live rabbits. The study took place at the Madigan Army Medical Center (Tacoma, Wash), and included 10 animals. In each rabbit, we injected the test compound in one ear and saline in the other ear (control). We injected hyaluronidase in 5 ears and elastase in 5 ears. After injection, the ears were contoured and splinted for 4 weeks. In the third phase, we changed the injection pathway in 5 animals. At 4 weeks, 4 (80%) of the 5 ears injected with hyaluronidase showed full response and 1 (20%) had a partial response. Of the 5 ears injected with elastase, 4 (80%) showed a full response while 1 (20%) demonstrated a partial response. There was a response in all 10 of the ears injected with a test compound. Of the 10 control ears, 3 (30%) showed a partial response. At 6 weeks, approximately 6 (30%) of the ears had maintained contour demonstrating a full response. The difference between the test ears and the control ears was statistically significant (P = .006). Compared with the control ears, the results were statistically significant for elastase (P = .004) and hyaluronidase (P = .02). Overall, both agents demonstrated a subjective and objective response compared with control ears. This study demonstrates that bioactive enzymes and splinting can be effective in correcting ear deformities in a rabbit model.
... scratching the ear canal, vigorous ear cleaning with cotton swabs, or putting foreign objects like bobby pins ... Also, never put objects into kids' ears, including cotton-tipped swabs. How Is Swimmer's Ear Treated? Treatment ...
Numerical analysis of ossicular chain lesion of human ear
NASA Astrophysics Data System (ADS)
Liu, Yingxi; Li, Sheng; Sun, Xiuzhen
2009-04-01
Lesion of ossicular chain is a common ear disease impairing the sense of hearing. A comprehensive numerical model of human ear can provide better understanding of sound transmission. In this study, we propose a three-dimensional finite element model of human ear that incorporates the canal, tympanic membrane, ossicular bones, middle ear suspensory ligaments/muscles, middle ear cavity and inner ear fluid. Numerical analysis is conducted and employed to predict the effects of middle ear cavity, malleus handle defect, hypoplasia of the long process of incus, and stapedial crus defect on sound transmission. The present finite element model is shown to be reasonable in predicting the ossicular mechanics of human ear.
Evidence for a Right-Ear Advantage in Newborn Hearing Screening Results.
Ari-Even Roth, Daphne; Hildesheimer, Minka; Roziner, Ilan; Henkin, Yael
2016-12-06
The aim of the present study was to investigate the effect of ear asymmetry, order of testing, and gender on transient-evoked otoacoustic emission (TEOAE) pass rates and response levels in newborn hearing screening. The screening results of 879 newborns, of whom 387 (study group) passed screening successfully in only one ear in the first TEOAE screening, but passed screening successfully in both ears thereafter, and 492 (control group) who passed screening successfully in both ears in the first TEOAE, were retrospectively examined for pass rates and TEOAE characteristics. Results indicated a right-ear advantage, as manifested by significantly higher pass rates in the right ear (61% and 39% for right and left ears, respectively) in the study group, and in 1.75 dB greater TEOAE response amplitudes in the control group. The right-ear advantage was enhanced when the first tested ear was the right ear (76%). When the left ear was tested first, pass rates were comparable in both ears. The right-ear advantage in pass rates was similar in females versus males, but manifested in 1.5 dB higher response amplitudes in females compared with males, regardless of the tested ear and order of testing in both study and control groups. The study provides further evidence for the functional lateralization of the auditory system at the cochlear level already apparent soon after birth in both males and females. While order of testing plays a significant role in the asymmetry in pass rates, the innate right-ear advantage seems to be a more dominant contributor. © The Author(s) 2016.
Anthropometric growth study of the ear in a Chinese population.
Zhao, Shichun; Li, Dianguo; Liu, Zhenzhong; Wang, Yibiao; Liu, Lei; Jiang, Duyin; Pan, Bo
2018-04-01
A large number of anthropometric studies of the auricle have been reported in different nations, but little data were available in the Chinese population. The aim of this study was to analyze growth changes in the ear by measuring the width and length of ears in a Chinese population. A total of 480 participants were enrolled and classified into 1-, 3-, 5-, 7-, 9-, 12-, 14-, and 18-year groups (half were boys and half were girls in each group). Ear length, ear width, body weight, and body length were measured and recorded; ear index was calculated according to ear length and ear width. The growth of auricle and differences between genders were analyzed. Growth of ear in relation to body height and weight and the degree of emphasis on the length and width of the auricle were also analyzed. Ear length and width increased with age. Ear length achieved its mature size in both 14-year-old males and females. Ear width reached its mature size in males at 7 years and in females at 5 years. Different trends of ear index were shown between males and females. People in this population paid more attention to the length than the width of the auricle. The data indicated that ear development followed increase in age. There were gender and ethnic difference in the development of ear. These results may have potential implications for the diagnosis of congenital malformations, syndromes, and planning of ear reconstruction surgery. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Evidence for a Right-Ear Advantage in Newborn Hearing Screening Results
Hildesheimer, Minka; Roziner, Ilan; Henkin, Yael
2016-01-01
The aim of the present study was to investigate the effect of ear asymmetry, order of testing, and gender on transient-evoked otoacoustic emission (TEOAE) pass rates and response levels in newborn hearing screening. The screening results of 879 newborns, of whom 387 (study group) passed screening successfully in only one ear in the first TEOAE screening, but passed screening successfully in both ears thereafter, and 492 (control group) who passed screening successfully in both ears in the first TEOAE, were retrospectively examined for pass rates and TEOAE characteristics. Results indicated a right-ear advantage, as manifested by significantly higher pass rates in the right ear (61% and 39% for right and left ears, respectively) in the study group, and in 1.75 dB greater TEOAE response amplitudes in the control group. The right-ear advantage was enhanced when the first tested ear was the right ear (76%). When the left ear was tested first, pass rates were comparable in both ears. The right-ear advantage in pass rates was similar in females versus males, but manifested in 1.5 dB higher response amplitudes in females compared with males, regardless of the tested ear and order of testing in both study and control groups. The study provides further evidence for the functional lateralization of the auditory system at the cochlear level already apparent soon after birth in both males and females. While order of testing plays a significant role in the asymmetry in pass rates, the innate right-ear advantage seems to be a more dominant contributor. PMID:27927982
77 FR 7890 - Semiannual Regulatory Agenda, Fall 2011
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-13
... wellness, healthy growth and development of young children, and the health and wellness of older adults and... and protectors; hair cleaning products, including shampoos and conditioners as subcategories... products; fuel conditioners; hair styling products; leather, vinyl, and rubber care products; lotions and...
Ravicz, M E; Rosowski, J J; Voigt, H F
1992-07-01
This is the first paper of a series dealing with sound-power collection by the auditory periphery of the gerbil. The purpose of the series is to quantify the physiological action of the gerbil's relatively large tympanic membrane and middle-ear air cavities. To this end the middle-ear input impedance ZT was measured at frequencies between 10 Hz and 18 kHz before and after manipulations of the middle-ear cavity. The frequency dependence of ZT is consistent with that of the middle-ear transfer function computed from extant data. Comparison of the impedance and transfer function suggests a middle-ear transformer ratio of 50 at frequencies below 1 kHz, substantially smaller than the anatomical value of 90 [Lay, J. Morph. 138, 41-120 (1972)]. Below 1 kHz the data suggest a low-frequency acoustic stiffness KT for the middle ear of 970 Pa/mm3 and a stiffness of the middle-ear cavity of 720 Pa/mm3 (middle-ear volume V MEC of 195 mm3); thus the middle-ear air spaces contribute about 70% of the acoustic stiffness of the auditory periphery. Manipulations of a middle-ear model suggest that decreases in V MEC lead to proportionate increases in KT but that further increases in middle-ear cavity volume produce only limited decreases in middle-ear stiffness. The data and the model point out that the real part of the middle-ear impedance at frequencies below 100 Hz is determined primarily by losses within the middle-ear cavity. The measured impedance is comparable in magnitude and frequency dependence to the impedance in several larger mammalian species commonly used in auditory research. A comparison of low-frequency stiffness and anatomical dimensions among several species suggests that the large middle-ear cavities in gerbil act to reduce the middle-ear stiffness at low frequencies. A description of sound-power collection by the gerbil ear requires a description of the function of the external ear.
Microbiomes of the normal middle ear and ears with chronic otitis media.
Minami, Shujiro B; Mutai, Hideki; Suzuki, Tomoko; Horii, Arata; Oishi, Naoki; Wasano, Koichiro; Katsura, Motoyasu; Tanaka, Fujinobu; Takiguchi, Tetsuya; Fujii, Masato; Kaga, Kimitaka
2017-10-01
The aim of this study was to profile and compare the middle ear microbiomes of human subjects with and without chronic otitis media. Prospective multicenter cohort study. All consecutive patients undergoing tympanoplasty surgery for chronic otitis media or ear surgery for conditions other than otitis media were recruited. Sterile swab samples were collected from the middle ear mucosa during surgery. The variable region 4 of the 16S rRNA gene in each sample were amplified using region-specific primers adapted for the Illumina MiSeq sequencer (Illumina, CA, USA)). The sequences were subjected to local blast and classified using Metagenome@KIN (World Fusion, Tokyo, Japan). In total, 155 participants were recruited from seven medical centers. Of these, 88 and 67 had chronic otitis media and normal middle ears, respectively. The most abundant bacterial phyla on the mucosal surfaces of the normal middle ears were Proteobacteria, followed by Actinobacteria, Firmicutes, and Bacteroidetes. The children and adults with normal middle ears differed significantly in terms of middle ear microbiomes. Subjects with chronic otitis media without active inflammation (dry ear) had similar middle ear microbiomes as the normal middle ears group. Subjects with chronic otitis media with active inflammation (wet ear) had a lower prevalence of Proteobacteria and a higher prevalence of Firmicutes than the normal middle ears. The human middle ear is inhabited by more diverse microbial communities than was previously thought. Alteration of the middle ear microbiome may contribute to the pathogenesis of chronic otitis media with active inflammation. 2b. Laryngoscope, 127:E371-E377, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Knowledge, Attitude and Practice of Ear Care in Coastal Karnataka.
Dosemane, Deviprasad; Ganapathi, Keerthan; Kanthila, Jayashree
2015-12-01
Ear as an organ is necessary for the perception of sound and body balance. Ear infection, diabetes mellitus, hypertension and excessive use of mobile phone for listening to music at high volume all can reduce hearing. No earlier study was available in the costal Karnataka population, regarding the practice of ear care. The study objective was to ascertain the level of knowledge of the community regarding ear care, to find out whether some of the common conditions affecting hearing are known and to find out the common practices involved in maintaining ear hygiene. This cross-sectional study was conducted on 500 subjects in two tertiary care hospitals by convenient sampling, using self-administered questionnaire. Knowledge, Attitude and Practice across the age groups, religion & education background were studied. Across different education groups, 66.7%-90% did not know that 'cold' can cause ear infection and 46.7%-75.0% did not know that diabetes and hypertension can reduce hearing. When there is ear pain or discharge, people put ear drops available at home in 48.3%-75.0% across 3 age groups; 58.5%-61.5% across 3 religions and 44.8%-67.9% across 5 education groups. No statistically significant difference was found in the practice of pouring oil into ears across religions. A total of 58.6%-100% daily clean inside the ear and 70-100% use cotton buds. General perception of the people is that ear is necessary only for hearing. Majority did not know that nasal infection can affect the ear and that DM and hypertension can cause hearing loss. When there is ear pain and discharge, most of the adults put drops that are available at home. Pouring oil into the ears and cleaning inside the ear canals is routinely practiced in costal Karnataka.
Keefe, Douglas H.; Abdala, Carolina
2008-01-01
The purpose of this study is to understand why otoacoustic emission (OAE) levels are higher in normal-hearing human infants relative to adults. In a previous study, distortion product (DP) OAE input/output (I/O) functions were shown to differ at f2=6 kHz in adults compared to infants through 6 months of age. These DPOAE I/O functions were used to noninvasively assess immaturities in forward/reverse transmission through the ear canal and middle ear [Abdala, C., and Keefe, D. H., (2006). J. Acoust Soc. Am. 120, 3832–3842]. In the present study, ear-canal reflectance and DPOAEs measured in the same ears were analyzed using a scattering-matrix model of forward and reverse transmission in the ear canal, middle ear, and cochlea. Reflectance measurements were sensitive to frequency-dependent effects of ear-canal and middle-ear transmission that differed across OAE type and subject age. Results indicated that DPOAE levels were larger in infants mainly because the reverse middle-ear transmittance level varied with ear-canal area, which differed by more than a factor of 7 between term infants and adults. The forward middle-ear transmittance level was −16 dB less in infants, so that the conductive efficiency was poorer in infants than adults. PMID:17348521
Ear asymmetries in middle-ear, cochlear, and brainstem responses in human infants
Keefe, Douglas H.; Gorga, Michael P.; Jesteadt, Walt; Smith, Lynette M.
2008-01-01
In 2004, Sininger and Cone-Wesson examined asymmetries in the signal-to-noise ratio (SNR) of otoacoustic emissions (OAE) in infants, reporting that distortion-product (DP)OAE SNR was larger in the left ear, whereas transient-evoked (TE)OAE SNR was larger in the right. They proposed that cochlear and brainstem asymmetries facilitate development of brain-hemispheric specialization for sound processing. Similarly, in 2006 Sininger and Cone-Wesson described ear asymmetries mainly favoring the right ear in infant auditory brainstem responses (ABRs). The present study analyzed 2640 infant responses to further explore these effects. Ear differences in OAE SNR, signal, and noise were evaluated separately and across frequencies (1.5, 2, 3, and 4 kHz), and ABR asymmetries were compared with cochlear asymmetries. Analyses of ear-canal reflectance and admittance showed that asymmetries in middle-ear functioning did not explain cochlear and brainstem asymmetries. Current results are consistent with earlier studies showing right-ear dominance for TEOAE and ABR. Noise levels were higher in the right ear for OAEs and ABRs, causing ear asymmetries in SNR to differ from those in signal level. No left-ear dominance for DPOAE signal was observed. These results do not support a theory that ear asymmetries in cochlear processing mimic hemispheric brain specialization for auditory processing. PMID:18345839
... Audiologist Perforated Eardrum What's Hearing Loss? Can Loud Music Hurt My Ears? What Is an Ear Infection? Swimmer's Ear Your Ears What's Earwax? View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...
Toxicity of monazite particulates and its attenuation with a complex of bio-protectors.
Katsnelson, B A; Yeremenko, Olga S; Privalova, Larissa I; Makeyev, O H; Degtyareva, Tamara D; Beresneva, Olga Yu; Valamina, Irene E; Minihaliyeva, Ilzira A; Sutunkova, Marina P; Kireyeva, Ekaterina P; Bukhantsev, V A; Dovzenko, E I; Minin, V V; Kulikov, E S; Kostykova, Svetlana V; Nazukin, A S
2009-01-01
Workers employed on mining, processing and storage of monazite are at risk of exposure to dust with expected adverse health effects. To study the adverse health effects of monazite particles in experiments on rats and to test the possibility of attenuating these effects. Outbred white rats were injected intratracheally with a suspension of ground monazite concentrate (MC) in order to investigate the cellular response of the lower airways 24 hours later and the organism's status 6 months after the injection. The bio-protective complex (BPC) tested in these experiments consisted of glutamate, an iodine preparation, methionine, a polyvitamin-polymineral composition, and/or "Eicosavitol" (fish oil preparation rich in PUFA, predominantly of the omega 3-group). Bio-protectors were administered together with the rat food and drink daily for one month before the MC injection in the short-term experiment, or over 6 months after such injection in the long-term experiment. MC induced manifestations of its cytotoxicity, fibrogenicity and systemic toxicity as well as genotoxicity. The tested BPC attenuated virtually all these effects. Although a similar protective potential of "Eicosavitol" against almost all of them was lower compared with that of BPC, combining BPC with "Eicosavitol" provided, as a rule, the greatest protective effect. It may be assumed that the many-sided adverse effects of MC on the organism is due, at least partially, to the presence in its composition of not only rare earth elements but also of natural radioisotopes of the thorium and uranium families. The combination of the bio-protectors tested was highly effective and may be recommended for administering in periodic preventive programmes to exposed workers.
NASA Astrophysics Data System (ADS)
Naghibolhosseini, Maryam
Our ability to hear depends primarily on sound waves traveling through the outer and middle ear toward the inner ear. Hence, the characteristics of the outer and middle ear affect sound transmission to/from the inner ear. The role of the middle and outer ear in sound transmission is particularly important for otoacoustic emissions (OAEs), which are sound signals generated in a healthy cochlea, and recorded by a sensitive microphone placed in the ear canal. OAEs are used to evaluate the health and function of the cochlea; however, they are also affected by outer and middle ear characteristics. To better assess cochlear health using OAEs, it is critical to quantify the impact of the outer and middle ear on sound transmission. The reported research introduces a noninvasive approach to estimate outer-middle ear transmission using distortion product otoacoustic emissions (DPOAEs). In addition, the role of the outer and middle ear on sound transmission was investigated by developing a physical/mathematical model, which employed fractional-order lumped elements to include the viscoelastic characteristics of biological tissues. Impedance estimations from wideband refectance measurements were used for parameter fitting of the model. The model was validated comparing its estimates of the outer-middle ear sound transmission with those given by DPOAEs. The outer-middle ear transmission by the model was defined as the sum of forward and reverse outer-middle ear transmissions. To estimate the reverse transmission by the model, the probe-microphone impedance was calculated through estimating the Thevenin-equivalent circuit of the probe-microphone. The Thevenin-equivalent circuit was calculated using measurements in a number of test cavities. Such modeling enhances our understanding of the roles of different parts of the outer and middle ear and how they work together to determine their function. In addition, the model would be potentially helpful in diagnosing pathologies of cochlear or middle ear origin.
Teasing in younger and older children with microtia before and after ear reconstruction.
Johns, Alexis L; Lewin, Sheryl L; Im, Daniel D
2017-06-01
This study prospectively measured teasing and emotional adjustment before and after ear reconstruction in younger and older children with microtia. Participants with isolated microtia (n = 28) were divided into two groups by age at surgery, with a younger group aged 3-5 years (n = 13) with a mean age of 4.0 (0.71) years at the time of surgery and an older group aged 6-10 years old (n = 15) with a mean age of 7.87 (1.30) years. Children and their parents were interviewed preoperatively and a year after surgery about teasing and emotions about their ear(s). Teasing began between the ages of 2.4-4.8 years. A third of the younger group and all of the older group reported preoperative teasing. Before surgery, the older group reported higher rates of negative emotions about their ear(s) and teasing was correlated for all ages with feeling sad, worried, and mad about their ear(s). After surgery, teasing and negative emotions significantly decreased with increased happiness about their ear(s). Postoperative teasing was correlated with trying to hide their ear(s). There were significant interactions from before to after surgery based on surgery age for frequency of teasing, sadness, and feeling mad, with the older group showing relatively greater change postoperatively. Teasing and negative emotions about their ear(s) decreased for all ages after surgery, with a potential protective factor seen in younger surgery age.
Gupta, Divya; Gulati, Achal; Gupta, Umang
2015-11-01
Socio-economic differences in the society have been a major cause for the discrepancy in disease and behavioural patterns in society. With 360 million people (32 million children) in the world suffering from disabling hearing losses, it is imperative to gain an insight into the impact of differences in socio-economic strata on children's ear health issues, their knowledge of ear ailments and attitude towards ear health so as to suggest policies addressing ear health issues. The study was carried out in two different school types namely government schools and private schools which represent wide difference in the socio-economic status of the students studying there. A questionnaire was administered to students aged 10 to 13 years to assess the current ear care practices, knowledge regarding ear ailments, attitude towards hearing and their adaptability to reform. The children belonging to higher socio-economic status were found to have lesser incidence of ear diseases and ear abuse, more referrals for ear ailments, lesser indulgence in risky ear health behaviours, better knowledge pool, positive attitude towards ear health and hearing and were more adaptable to change for better hearing. Structures of social disparity are essential determinants of ear health acting both independently and through their influence on behavioural determinants of health. Increasing awareness of ear health issues at the school level itself should be one of the goals of health care providers. Copyright © 2015. Published by Elsevier Ireland Ltd.
Middle Ear Infections (For Parents)
... Staying Safe Videos for Educators Search English Español Middle Ear Infections KidsHealth / For Parents / Middle Ear Infections What's ... en español Infecciones del oído medio What Are Middle Ear Infections? Ear infections happen when viruses or bacteria ...
Schmuziger, N; Hauser, R; Probst, R
1996-06-01
Both the amplitude and power spectra of otoacoustic emissions are affected by the transfer properties of the middle ear. This prospective study examined the influence of eustachian tube dysfunction on transiently evoked otoacoustic emissions (TEOAEs) and distortion-product otoacoustic emissions (DPOAEs). In all, 18 ears were studied that exhibited negative middle ear pressures with or without middle ear fluid. Measurements were performed at the time of diagnosis during the recovery stage, and after the middle ear became normally ventilated. Findings showed that TEOAE and DPOAE levels increased while airbone gaps were reduced by an average of 8 dB after negative middle ear pressures returned from -400 daPa to a normal state. There was a tendency for negative middle ear pressure to affect DPOAEs more in the 1-kHz region than in higher frequencies. By contrast, TEOAEs and airbone gaps were more uniformly affected across the entire frequency range. These results for ears with eustachian tube dysfunction were somewhat different from those results of studies obtained in healthy ears tested during experimental changes in middle ear pressure.
Missing links in some curious auditory phenomena: a tale from the middle ear.
Carpenter, Michelle S; Cacace, Anthony T; Mahoney, Marty J
2012-02-01
Broadband middle ear power reflectance (BMEPR) is an emerging noninvasive electroacoustic measure that evaluates transmission/reflection properties of the middle ear in high resolution. It is applicable over the entire age continuum and is rapid to perform. However, it remains to be determined if BMEPR is just an incremental step in the evolution of middle ear assessment or a major advance in the way middle ear function can be evaluated. To evaluate effects of age, gender, ear, and frequency on BMEPR measurements in adults without a history of middle ear disease and to assess whether these factors require consideration in test development; to review how these data may influence active physiologic process within the inner ear; to consider how they reconcile with previously published results; and to suggest applications for future research. Prospective, cross-sectional, multivariate analysis to evaluate the effects of age, gender, ear, and frequency on BMEPR in humans without a history of middle ear disease and no air-bone gaps exceeding 10 dB for any frequency. Fifty-six adults in two age groups (Group 1: 18-25 yr, n = 28; Group 2: ≥50 and <66 yr, n = 28). Each age group was stratified by ear and gender in a balanced design. Pure tone air conduction and bone-conduction audiometry was conducted in a commercial sound booth, using a clinical audiometer with standard earphones enclosed in supra-aural ear cushions, and a standard bone-conduction oscillator and headband to evaluate for air-bone gaps. Broadband middle ear power reflectance was measured using a calibrated, commercially available computer-controlled system that incorporated a high quality probe assembly to transduce stimuli and record acoustic responses from the ear canal. Data were analyzed with a four-way (2 × 2 × 2 × 16) repeated measures analysis-of-variance (ANOVA) to evaluate the effects of age group (young vs. old), gender (male vs. female), ear (left vs. right), and frequency (258 to 5040 Hz) on BMEPR. The ANOVA revealed a significant main effect of frequency. There were also gender × ear, gender × frequency, and age × gender × ear interactions. The three-way, age × gender × ear interaction captured the essence of results and revealed lowest power reflectance values in younger females and for right ears. This trend partially reversed in the older age group where higher power reflectance values were observed only in right ears of older females. The significant effects of age, gender, ear, and frequency on BMEPR parallel ear- and gender-related differences in hearing sensitivity, ear, and gender differences in the prevalence of spontaneous otoacoustic emissions (OAEs), gender differences in the magnitude of transient evoked OAEs, and ear differences in transient evoked contralateral OAE suppression effects reported in the literature. While original discussions of these aforementioned effects focused primarily on endocochlear and olivocochlear mechanisms, the BMEPR measurements reported herein suggest that middle ear transmission characteristics may also play a role. American Academy of Audiology.
... swabs or other small objects into the ear Middle ear infection Other causes of ear discharge include: Eczema ... tube surgery - what to ask your doctor Images Ear anatomy Eardrum repair - series References Bauer CA, Jenkins HA. Otologic symptoms and syndromes. In: Flint PW, Haughey BH, Lund V, et ...
49 CFR 227.109 - Audiometric testing program.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION OCCUPATIONAL NOISE EXPOSURE Occupational Noise Exposure for Railroad... occupational noise in excess of the action level. Hearing protectors may be used as a substitute for the requirement that baseline audiograms be preceded by 14 hours without exposure to occupational noise. (4) The...
Strategies for Discovery of Small Molecule Radiation Protectors and Radiation Mitigators
Greenberger, Joel S.; Clump, David; Kagan, Valerian; Bayir, Hülya; Lazo, John S.; Wipf, Peter; Li, Song; Gao, Xiang; Epperly, Michael W.
2011-01-01
Mitochondrial targeted radiation damage protectors (delivered prior to irradiation) and mitigators (delivered after irradiation, but before the appearance of symptoms associated with radiation syndrome) have been a recent focus in drug discovery for (1) normal tissue radiation protection during fractionated radiotherapy, and (2) radiation terrorism counter measures. Several categories of such molecules have been discovered: nitroxide-linked hybrid molecules, including GS-nitroxide, GS-nitric oxide synthase inhibitors, p53/mdm2/mdm4 inhibitors, and pharmaceutical agents including inhibitors of the phosphoinositide-3-kinase pathway and the anti-seizure medicine, carbamazepine. Evaluation of potential new radiation dose modifying molecules to protect normal tissue includes: clonogenic radiation survival curves, assays for apoptosis and DNA repair, and irradiation-induced depletion of antioxidant stores. Studies of organ specific radioprotection and in total body irradiation-induced hematopoietic syndrome in the mouse model for protection/mitigation facilitate rational means by which to move candidate small molecule drugs along the drug discovery pipeline into clinical development. PMID:22655254
Development of single cell protectors for sealed silver-zinc cells, phase 1
NASA Technical Reports Server (NTRS)
Imamura, M. S.; Donovan, R. L.; Lear, J. W.; Murray, B.
1976-01-01
A single cell protector (SCP) assembly capable of protecting a single silver-zinc (Ag Zn) battery cell was designed, fabricated, and tested. The SCP provides cell-level protection against overcharge and overdischarge by a bypass circuit. The bypass circuit consists of a magnetic-latching relay that is controlled by the high and low-voltage limit comparators. Although designed specifically for secondary Ag-Zn cells, the SCP is flexible enough to be adapted to other rechargeable cells. Eighteen SCPs were used in life testing of an 18-cell battery. The cells were sealed Ag-Zn system with inorganic separators. For comparison, another 18-cell battery was subjected to identical life test conditions, but with battery-level protection rather than cell-level. An alternative approach to the SCP design in the form of a microprocessor-based system was conceptually designed. The comparison of SCP and microprocessor approaches is also presented and a preferred approach for Ag-Zn battery protection is discussed.
Genetic Architecture of Ear Fasciation in Maize (Zea mays) under QTL Scrutiny
Mendes-Moreira, Pedro; Alves, Mara L.; Satovic, Zlatko; dos Santos, João Pacheco; Santos, João Nina; Souza, João Cândido; Pêgo, Silas E.; Hallauer, Arnel R.; Vaz Patto, Maria Carlota
2015-01-01
Maize ear fasciation Knowledge of the genes affecting maize ear inflorescence may lead to better grain yield modeling. Maize ear fasciation, defined as abnormal flattened ears with high kernel row number, is a quantitative trait widely present in Portuguese maize landraces. Material and Methods Using a segregating population derived from an ear fasciation contrasting cross (consisting of 149 F2:3 families) we established a two location field trial using a complete randomized block design. Correlations and heritabilities for several ear fasciation-related traits and yield were determined. Quantitative Trait Loci (QTL) involved in the inheritance of those traits were identified and candidate genes for these QTL proposed. Results and Discussion Ear fasciation broad-sense heritability was 0.73. Highly significant correlations were found between ear fasciation and some ear and cob diameters and row number traits. For the 23 yield and ear fasciation-related traits, 65 QTL were identified, out of which 11 were detected in both environments, while for the three principal components, five to six QTL were detected per environment. Detected QTL were distributed across 17 genomic regions and explained individually, 8.7% to 22.4% of the individual traits or principal components phenotypic variance. Several candidate genes for these QTL regions were proposed, such as bearded-ear1, branched silkless1, compact plant1, ramosa2, ramosa3, tasselseed4 and terminal ear1. However, many QTL mapped to regions without known candidate genes, indicating potential chromosomal regions not yet targeted for maize ear traits selection. Conclusions Portuguese maize germplasm represents a valuable source of genes or allelic variants for yield improvement and elucidation of the genetic basis of ear fasciation traits. Future studies should focus on fine mapping of the identified genomic regions with the aim of map-based cloning. PMID:25923975
Ear canal dynamic motion as a source of power for in-ear devices
NASA Astrophysics Data System (ADS)
Delnavaz, Aidin; Voix, Jérémie
2013-02-01
Ear canal deformation caused by temporomandibular joint (jaw joint) activity, also known as "ear canal dynamic motion," is introduced in this paper as a candidate source of power to possibly recharge hearing aid batteries. The geometrical deformation of the ear canal is quantified in 3D by laser scanning of different custom ear moulds. An experimental setup is proposed to measure the amount of power potentially available from this source. The results show that 9 mW of power is available from a 15 mm3 dynamic change in the ear canal volume. Finally, the dynamic motion and power capability of the ear canal are investigated in a group of 12 subjects.
Inner Ear Drug Delivery for Auditory Applications
Swan, Erin E. Leary; Mescher, Mark J.; Sewell, William F.; Tao, Sarah L.; Borenstein, Jeffrey T.
2008-01-01
Many inner ear disorders cannot be adequately treated by systemic drug delivery. A blood-cochlear barrier exists, similar physiologically to the blood-brain barrier, which limits the concentration and size of molecules able to leave the circulation and gain access to the cells of the inner ear. However, research in novel therapeutics and delivery systems has led to significant progress in the development of local methods of drug delivery to the inner ear. Intratympanic approaches, which deliver therapeutics to the middle ear, rely on permeation through tissue for access to the structures of the inner ear, whereas intracochlear methods are able to directly insert drugs into the inner ear. Innovative drug delivery systems to treat various inner ear ailments such as ototoxicity, sudden sensorineural hearing loss, autoimmune inner ear disease, and for preserving neurons and regenerating sensory cells are being explored. PMID:18848590
Transmission matrix analysis of the chinchilla middle ear
Songer, Jocelyn E.; Rosowski, John J.
2008-01-01
Despite the common use of the chinchilla as an animal model in auditory research, a complete characterization of the chinchilla middle ear using transmission matrix analysis has not been performed. In this paper we describe measurements of middle-ear input admittance and stapes velocity in ears with the middle-ear cavity opened under three conditions: intact tympano-ossicular system and cochlea, after the cochlea has been drained, and after the stapes has been fixed. These measurements, made with stimulus frequencies of 100–8000 Hz, are used to define the transmission matrix parameters of the middle ear and to calculate the cochlear input impedance as well as the middle-ear output impedance. This transmission characterization of the chinchilla middle ear will be useful for modeling auditory sensitivity in the normal and pathological chinchilla ear. PMID:17672642
See your provider if your ears are blocked with wax and you are unable to remove the wax. Also call if you have an ear wax blockage and you develop new symptoms, such as: Drainage from the ear Ear pain Fever Hearing loss that continues after you clean the wax
A new method for correcting type I and type II constricted (cup and lop) ears.
Xiaogeng, Hu; Hongxing, Zhuang; Qinghua, Yang; Haiyue, Jiang; Yanyong, Zhao
2006-01-01
Tanzer suggested the term "constricted ear," denoting a spectrum of deformities limited to the superior third of the ear. Tanzer classified the constricted ear into three types. Type I ears have involvement of the helix, which usually is flattened. Type II ears show involvement of both the helix and the scapha. With type III ears, the auricle is rolled into a nearly tubular form that some authors regard as a form of microtia. The authors' new method for correcting the constricted ear varies in accordance with the diverse degree of deformity. The new method was used to correct constricted ears through a one-stage operation in eight type I cases. For the remaining six type 2 cases, the methods were combined with composite grafting. Most of the patients were satisfied with the final results. Therefore, the authors conclude that their approach is suitable for the treatment of type I and type II constricted ears.
Strain, George M; Fernandes, Asia J
2015-06-01
Otitis externa is frequently accompanied by otitis media, yet it can be difficult to evaluate the tympanum, middle ear and auditory tube without the use of advanced radiographic imaging. The objective was to develop techniques for tympanometry testing in conscious dogs and to present normative data for clinical use of this equipment to enable assessment of the tympanum, middle ear and auditory tube. Sixteen hounds (14 female) from a school teaching colony. Dogs were gently restrained in a standing position. After cleaning of the ear canal, a tympanometer probe tip extension was placed in the vertical canal and automated testing performed using a handheld device. Both ears were tested in all dogs. Acceptable recordings were obtained from both ears of 13 dogs, from one ear in each of two dogs and from neither ear of one dog, resulting in data from 28 of 32 (88%) ears. Otoscopic examination confirmed the absence of inflammation or any other obvious explanation for the noncompliant dogs. No significant differences were seen between ears for any measure. Normative data are reported for peak compliance, peak compliance pressure, gradient and ear canal volume. Tympanograms can be recorded in conscious dogs to assist in the evaluation of the middle ear structures. © 2015 ESVD and ACVD.
Munro, K J; Davis, J
2003-04-01
The purpose of the study was to compare the measured real-ear sound pressure level (SPL) of audiometer output with the derived real-ear SPL obtained by adding the coupler to dial difference (CDD) and real-ear to coupler difference (RECD) to the audiometer dial reading. The real-ear SPL and RECD were measured in one ear of 16 normally hearing subjects using a probe-tube microphone. The CDD transform and the RECD transfer function were measured in an HA1 and an HA2 2-cc coupler using an EAR-LINK foam ear-tip or a customized earmold. The RECD transfer function was measured using the EARTone ER 3A and the Audioscan RE770 insert earphone. The procedures were very reliable with mean differences on retest of less than 1 dB. The mean difference between the measured and derived real-ear SPL was generally less than 1 dB and rarely exceeded 3 dB in any subject. The CDD measured for an individual audiometer and the RECD measured for an individual ear can be used to derive a valid estimate of real-ear SPL when it has not been possible to measure this directly.
Ravicz, Michael E.; Rosowski, John J.
2012-01-01
The middle-ear input admittance relates sound power into the middle ear (ME) and sound pressure at the tympanic membrane (TM). ME input admittance was measured in the chinchilla ear canal as part of a larger study of sound power transmission through the ME into the inner ear. The middle ear was open, and the inner ear was intact or modified with small sensors inserted into the vestibule near the cochlear base. A simple model of the chinchilla ear canal, based on ear canal sound pressure measurements at two points along the canal and an assumption of plane-wave propagation, enables reliable estimates of YTM, the ME input admittance at the TM, from the admittance measured relatively far from the TM. YTM appears valid at frequencies as high as 17 kHz, a much higher frequency than previously reported. The real part of YTM decreases with frequency above 2 kHz. Effects of the inner-ear sensors (necessary for inner ear power computation) were small and generally limited to frequencies below 3 kHz. Computed power reflectance was ∼0.1 below 3.5 kHz, lower than with an intact ME below 2.5 kHz, and nearly 1 above 16 kHz. PMID:23039439
Ishihara, Hisashi; Kariya, Shin; Okano, Mitsuhiro; Zhao, Pengfei; Maeda, Yukihide; Nishizaki, Kazunori
2016-10-01
Significant expression of macrophage migration inhibitory factor and its receptor (CD74) was observed in both the middle ear and inner ear in experimental otitis media in mice. Modulation of macrophage migration inhibitory factor and its signaling pathway might be useful in the management of inner ear inflammation due to otitis media. Inner ear dysfunction secondary to otitis media has been reported. However, the specific mechanisms involved are not clearly understood. The aim of this study is to investigate the expression of macrophage migration inhibitory factor and CD74 in the middle ear and inner ear in lipopolysaccharide-induced otitis media. BALB/c mice received a transtympanic injection of either lipopolysaccharide or phosphate-buffered saline (PBS). The mice were sacrificed 24 h after injection, and temporal bones were processed for polymerase chain reaction (PCR) analysis, histologic examination, and immunohistochemistry. PCR examination revealed that the lipopolysaccharide-injected mice showed a significant up-regulation of macrophage migration inhibitory factor in both the middle ear and inner ear as compared with the PBS-injected control mice. The immunohistochemical study showed positive reactions for macrophage migration inhibitory factor and CD74 in infiltrating inflammatory cells, middle ear mucosa, and inner ear in the lipopolysaccharide-injected mice.
Cordas, Emily A.; Ng, Lily; Hernandez, Arturo; Kaneshige, Masahiro; Cheng, Sheue-Yann
2012-01-01
Thyroid hormone is critical for auditory development and has well-known actions in the inner ear. However, less is known of thyroid hormone functions in the middle ear, which contains the ossicles (malleus, incus, stapes) that relay mechanical sound vibrations from the outer ear to the inner ear. During the later stages of middle ear development, prior to the onset of hearing, middle ear cavitation occurs, involving clearance of mesenchyme from the middle ear cavity while the immature cartilaginous ossicles attain appropriate size and ossify. Using in situ hybridization, we detected expression of Thra and Thrb genes encoding thyroid hormone receptors α1 and β (TRα1 and TRβ, respectively) in the immature ossicles, surrounding mesenchyme and tympanic membrane in the mouse. Thra+/PV mice that express a dominant-negative TRα1 protein exhibited deafness with elevated auditory thresholds and a range of middle ear abnormalities including chronic persistence of mesenchyme in the middle ear into adulthood, markedly enlarged ossicles, and delayed ossification of the ossicles. Congenitally hypothyroid Tshr−/− mice and TR-deficient Thra1−/−;Thrb−/− mice displayed similar abnormalities. These findings demonstrate that middle ear maturation is TR dependent and suggest that the middle ear is a sensitive target for thyroid hormone in development. PMID:22253431
Comparison of packing material in an animal model of middle ear trauma.
Perez, Enrique; Hachem, Ralph Abi; Carlton, Daniel; Bueno, Isabel; Vernon, Stephen; Van De Water, Thomas R; Angeli, Simon I
2016-01-01
To compare the performance of absorbable gelatin sponge (AGS) with polyurethane foam (PUF) as middle ear packing material after mucosal trauma. Using a randomized, controlled and blinded study design fifteen guinea pigs underwent middle ear surgery with mucosal trauma performed on both ears. One ear was packed with either PUF or AGS while the contralateral ear remained untreated and used as non-packed paired controls. Auditory brainstem response (ABR) thresholds were measured pre-operatively and repeated at 1, 2, and 6weeks postoperatively. Histological analysis of middle ear mucosa was done in each group to evaluate the inflammatory reaction and wound healing. Another eighteen animals underwent middle ear wounding and packing in one ear while the contralateral ear was left undisturbed as control. Twelve guinea pigs were euthanized at 2weeks postoperatively, and six were euthanized at 3days post-operatively. Mucosal samples were collected for analysis of TGF-β1 levels by enzyme-linked immunosorbent assay. ABR recordings demonstrate that threshold level changes from baseline were minor in PUF packed and control ears. Threshold levels were higher in the AGS packed ears compared with both control and PUF packed ears for low frequency stimuli. Histological analysis showed persistence of packing material at 6weeks postoperatively, inflammation, granulation tissue formation, foreign body reaction and neo-osteogenesis in both AGS and PUF groups. TGF-β1 protein levels did not differ between groups. PUF and AGS packing cause inflammation and neo-osteogenesis in the middle ear following wounding of the mucosa and packing. Copyright © 2016 Elsevier Inc. All rights reserved.
Kim, Young Soo; Chung, Seum
2016-04-01
A constricted ear, also known as a cup ear or lop ear, is a deformity characterized by curling of the upper portion of the ear, including the helix, scapha, and antihelix. In Tanzer's classification, group II constricted ears have deformities involving the helix and the scapha. Although partial or total absence of the superior crus of the antihelix has been noted in group II constricted ears, most plastic surgeons have corrected group II constricted ears using the expansion technique and skin flaps, without formation of the superior crus. However, the expansion technique does not always yield satisfactory results in group II constricted ears. Between May 2011 and April 2014, the authors operated on 21 patients with group II constricted ears using the technique described in this study. The follow-up period ranged from 2 months to 2 years. In our procedure for correcting group II constricted ears, we focused on restoring the superior crus of the antihelix. As a strong superior crus acts as a strut in the upper third of the ear, it supports the helical rim and creates the scapha. Eventually, the newly formed superior crus enables the helical rim to expand in the upper third of the constricted ear. In this article, we present our method of correcting group II constricted ears, in which the superior crus is constructed as a strut and cartilage expansion grafts are used. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Sadé, Jacob; Ar, Amos; Fuchs, Camil
2003-03-01
We compared 17 patients (29 ears) with barotrauma with 171 patients suffering from "chronic ears" (secretory otitis media, atelectasis, or previously operated cholesteatoma). The patients with "chronic ears" were followed up prospectively, and none were found to suffer from barotrauma after flying on a commercial airplane. The mastoid pneumatization (seen on lateral mastoid radiographs) was significantly larger in ears with barotrauma, averaging 16.85 cm2, versus 12.9 cm2 in normal controls, whereas in "chronic ears" it was only 3.6 cm2. During flight on a commercial airplane, the middle ear has to equalize about 20% of its gas volume with the ambient pressure. This equalization must happen within 15 to 20 minutes of ascent and descent in order to avoid barotrauma. This 20% is a fivefold greater task for ears with a large mastoid pneumatization than for ears with an undeveloped pneumatization; "chronic ears" usually have an undeveloped mastoid pneumatization. The smaller the middle ear (mastoid) volume, the smaller the volume of gas needed to pass through the eustachian tube in order to equalize pressure changes during flying. This factor may explain why "chronic ears" rarely suffer from barotrauma. It also implies that eustachian tubes of secretory otitis, atelectatic, and cholesteatomatous ears have little problem in equalizing large pressure differences (over 2,000 mm H2O) within 15 to 20 minutes of landing, in contrast to what has been traditionally believed. Individuals with "chronic ears" can be advised that they can fly safely.
ERIC Educational Resources Information Center
DiJulio, Betsy
2011-01-01
In this article, the author describes an art project wherein students make fanciful connections between art and medicine. This project challenges students to interpret "ear idioms" (e.g. "blow it out your ear," "in one ear and out the other") by relying almost entirely on realistic ear drawings, the placement of them, marks, and values. In that…
[Constricted ear therapy with free auricular composite grafts].
Liu, Tun; Zhang, Lian-sheng; Zhuang, Hong-xing; Zhang, Ke-yuan
2004-03-01
A simple and effective therapy for single side constricted ear. Transplanting normal side free composite auricular grafts to constricted ear (15 patients and 15 sides), then lengthening the helix, exposing the scapha, correcting deformity. The 15 patients composite grafts all survived. The helix has been lengthened, the scapha exposed, the normal ear reduced, the constricted ear augmented and two sides ear have become symmetry. This method is simple and results are satisfied.
Computational Modeling of Blast Wave Transmission Through Human Ear.
Leckness, Kegan; Nakmali, Don; Gan, Rong Z
2018-03-01
Hearing loss has become the most common disability among veterans. Understanding how blast waves propagate through the human ear is a necessary step in the development of effective hearing protection devices (HPDs). This article presents the first 3D finite element (FE) model of the human ear to simulate blast wave transmission through the ear. The 3D FE model of the human ear consisting of the ear canal, tympanic membrane, ossicular chain, and middle ear cavity was imported into ANSYS Workbench for coupled fluid-structure interaction analysis in the time domain. Blast pressure waveforms recorded external to the ear in human cadaver temporal bone tests were applied at the entrance of the ear canal in the model. The pressure waveforms near the tympanic membrane (TM) in the canal (P1) and behind the TM in the middle ear cavity (P2) were calculated. The model-predicted results were then compared with measured P1 and P2 waveforms recorded in human cadaver ears during blast tests. Results show that the model-derived P1 waveforms were in an agreement with the experimentally recorded waveforms with statistic Kurtosis analysis. The FE model will be used for the evaluation of HPDs in future studies.
Morphological Variations and Biometrics of Ear: An Aid to Personal Identification.
Verma, Pradhuman; Sandhu, Harpreet Kaur; Verma, Kanika Gupta; Goyal, Sharry; Sudan, Madhu; Ladgotra, Amit
2016-05-01
The morphological characteristics and dimensions of external ear vary in different human ethnic races which can be utilized in forensics for personal identification of living or deceased. To determine uniqueness of morphological and biometric variations of both ears for individualization among North East (NE) and North West (NW) subpopulation of India. The study was conducted on randomly selected 80 students, 40 from each subgroup. Nine ear parameters were recorded twice using digital Vernier's caliper by single investigator and two indices (Ear Index and Lobule Index) were calculated for both the ears. Morphological ear shapes and lobule attachment were also noted. Pearson's coefficient correlation test was performed on cross-tabulations to evaluate significant relationship between different variables. Of the total 35% free and 65% attached ear lobes were noted in both population groups. Oval ear shape was most commonly noted followed by triangular, rectangular and round in both populations. On comparing anthropometric measurements of ears in two populations it was found that except the tragus length and lobule index all other values were noted more in NW population. No statistical difference was found in ear and lobular indices of males and females although the left ear index and lobule index were found to be higher than right in both populations except in NW females where right lobule index was recorded more than left. The results obtained can be used in anthropological and forensic sciences for the inclusion and exclusion of persons for identification on the basis of ear variations.
Kabadi, S J; Ruhl, D S; Mukherjee, S; Kesser, B W
2018-02-01
Middle ear space is one of the most important components of the Jahrsdoerfer grading system (J-score), which is used to determine surgical candidacy for congenital aural atresia. The purpose of this study was to introduce a semiautomated method for measuring middle ear volume and determine whether middle ear volume, either alone or in combination with the J-score, can be used to predict early postoperative audiometric outcomes. A retrospective analysis was conducted of 18 patients who underwent an operation for unilateral congenital aural atresia at our institution. Using the Livewire Segmentation tool in the Carestream Vue PACS, we segmented middle ear volumes using a semiautomated method for all atretic and contralateral normal ears on preoperative high-resolution CT imaging. Postsurgical audiometric outcome data were then analyzed in the context of these middle ear volumes. Atretic middle ear volumes were significantly smaller than those in contralateral normal ears ( P < .001). Patients with atretic middle ear volumes of >305 mm 3 had significantly better postoperative pure tone average and speech reception thresholds than those with atretic ears below this threshold volume ( P = .01 and P = .006, respectively). Atretic middle ear volume incorporated into the J-score offered the best association with normal postoperative hearing (speech reception threshold ≤ 30 dB; OR = 37.8, P = .01). Middle ear volume, calculated in a semiautomated fashion, is predictive of postsurgical audiometric outcomes, both independently and in combination with the conventional J-score. © 2018 by American Journal of Neuroradiology.
Histologic characterization of the cat middle ear: in sickness and in health.
Sula, M M; Njaa, B L; Payton, M E
2014-09-01
The purpose of this study was to establish microscopic normal in the middle ear of the cat while concurrently characterizing gross and microscopic lesions reflecting spontaneous otitis media. Both ears from 50 cats were examined grossly and processed for histologic examination of the external, middle, and internal ear on a single slide. Gross lesions of the middle ear were present in 14 of 100 (14%) and included turbid fluid, frank pus, hemorrhage, and fibrous thickening of the auricular mucoperiosteum. Histologically, 48 of 100 (48%) ears had evidence of ongoing or previous inflammatory middle ear disease, including proteinaceous fluid; vascular ectasia; expansion of the auricular mucoperiosteum by neutrophils, lymphocytes, and macrophages; cholesterol clefts; hemorrhage; fibrin; granulation tissue; membranous pseudo-glands; fibrosis; proliferation and/or osteolysis of the tympanic and septum bullae. Histologic lesions were identified in 34 of 100 ears (34%) lacking gross evidence of disease. Ears were classified histologically as either normal (52/100 [52%]) or diseased (48/100 [48%]). Diseased ears were further classified as mild to moderate (37/100 [37%]) or severely (11/100 [11%]) affected. Internal ear involvement was present in 11 of 100 (11%) ears. Histologic evidence of middle ear disease in cats is far greater than gross lesions or clinical literature suggests; further investigation and correlation of clinical and histologic disease are warranted. With minimal additional preparation, diagnostic specimens may be readily prepared and evaluated for this integral sensing organ. © The Author(s) 2013.
Coward, Trevor J; Richards, Robin; Scott, Brendan J J
2014-01-01
People with hemifacial microsomia may be missing an ear on the affected side of the face. The principal aim of the study was to develop a morphing technique and to determine whether it could be used to appropriately position an artificial ear, as well as to give an indication of prosthesis size in comparison with the natural ear. Comparisons also were made between the artificial ears being worn by the patients with their natural ears. Data from stereophotogrammetry images of the faces of 10 people were converted into stereolithographic format. Anthropometric points on the face and ear of the unaffected side were plotted. By a process of scaling, the distance between facial landmarks on the unaffected side was estimated for the affected side so as to identify where the morphed ear would be positioned once generated. Generally, the morphed ears appeared to be in acceptable positions. There was a statistically significant difference between the position of the morphed and natural ears (P = .011), as well as the artificial and natural ears (P = .001), but this was unlikely to have any clinical implications. There were no significant differences among the sizes of the natural, morphed, and artificial ears (P = .072). Morphing appears to offer a more precise way of planning the positioning and construction of an artificial ear on patients with hemifacial microsomia than traditional methods. Differences in facial shape on either side of the face may impact on the process. This requires further study.
The prominent antihelix and helix--the myth of the 'overcorrected' ear in otoplasty.
Shokrollahi, Kayvan; Manning, Steven; Sadri, Amir; Molajo, Adeyinka; Lineaweaver, William
2015-06-01
Classic teaching of ear anatomy in the context of otoplasty states that if the antihelical fold is more prominent than the helical fold after surgery then the ear is "overcorrected." We set out to explore the role of the antihelix in normal ear anatomy, its relevance to aesthetic perceptions of the ear, and a snapshot of its incidence in nonoperated ears. To readily identify junior staff in our department, their color photographs, names, and contact details are posted on every ward. Using digital methods, we cropped the left ear out of the source images, making them unidentifiable. Clinical and nonclinical staff in our unit were asked to choose their favorite and their least favorite ears based on their aesthetic appeal. Responses were tabulated and the 2 most popular ears were compared. The preferred ear did not conform to the traditional dogma because it had a prominent antihelix and was statistically significant when compared to other choices. We also noted that a prominent antihelix is common among the general population and among colleagues within the department, and hence "normal." Also interesting was that the helix of the ear chosen as the most aesthetic was also the ear where the helix was almost touching the side of the head. We found that when judging the aesthetic nature of the "virgin" ear, antihelical fold prominence did not appear to be a negative attribute. Indeed, we noted that a prominent antihelix was a common attribute, and we conclude that this was a normal variant without undue negative aesthetic stigma. A surgically corrected ear should not necessarily be regarded as a poor outcome simply on the basis of antihelical prominence. Furthermore, we postulate that patients who have a prominent antihelix might be part of a spectrum of individuals who might have had the subtype of prominent ears featuring a deep conchal bowl. Finally, although not tested directly, it appears that we do not have an idea of our own ear shape, as none of the participants was able to recognize their own ear from the photographs.
26 CFR 148.1-5 - Constructive sale price.
Code of Federal Regulations, 2012 CFR
2012-04-01
... of articles listed in Chapter 32 of the Internal Revenue Code (other than combinations) that embraces... section. For the rule applicable to combinations of two or more articles, see subdivision (iv) of this..., perforating, cutting, and dating machines, and other check protector machine devices; (o) Taxable cash...
26 CFR 148.1-5 - Constructive sale price.
Code of Federal Regulations, 2013 CFR
2013-04-01
... of articles listed in Chapter 32 of the Internal Revenue Code (other than combinations) that embraces... section. For the rule applicable to combinations of two or more articles, see subdivision (iv) of this..., perforating, cutting, and dating machines, and other check protector machine devices; (o) Taxable cash...
26 CFR 148.1-5 - Constructive sale price.
Code of Federal Regulations, 2014 CFR
2014-04-01
... of articles listed in Chapter 32 of the Internal Revenue Code (other than combinations) that embraces... section. For the rule applicable to combinations of two or more articles, see subdivision (iv) of this..., perforating, cutting, and dating machines, and other check protector machine devices; (o) Taxable cash...
40 CFR 62.14352 - Designated facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Requirements for Municipal Solid Waste Landfills That Commenced Construction Prior to May 30, 1991 and Have Not... facility to which this subpart applies is each municipal solid waste landfill in all States, protectorates... for landfills exempted by paragraphs (b) and (c) of this section. (1) The municipal solid waste...
40 CFR 62.14352 - Designated facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Requirements for Municipal Solid Waste Landfills That Commenced Construction Prior to May 30, 1991 and Have Not... facility to which this subpart applies is each municipal solid waste landfill in all States, protectorates... for landfills exempted by paragraphs (b) and (c) of this section. (1) The municipal solid waste...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uchida, Shinji; Ozaki, Masayori; Suzuki, Keiko
Long-term administration of ({minus})-epigallocatechin 3-O-gallate (EGCG) to mice through drinking water prevented radiation-induced increase of lipid peroxides in liver and significantly prolonged life span after lethal whole-body X-irradiation. The result indicates validity of this green-tea component as an orally active radio-protector of very low toxicity.
Clinical investigation and mechanism of air-bone gaps in large vestibular aqueduct syndrome.
Merchant, Saumil N; Nakajima, Hideko H; Halpin, Christopher; Nadol, Joseph B; Lee, Daniel J; Innis, William P; Curtin, Hugh; Rosowski, John J
2007-07-01
Patients with large vestibular aqueduct syndrome (LVAS) often demonstrate an air-bone gap at the low frequencies on audiometric testing. The mechanism causing such a gap has not been well elucidated. We investigated middle ear sound transmission in patients with LVAS, and present a hypothesis to explain the air-bone gap. Observations were made on 8 ears from 5 individuals with LVAS. The diagnosis of LVAS was made by computed tomography in all cases. Investigations included standard audiometry and measurements of umbo velocity by laser Doppler vibrometry (LDV) in all cases, as well as tympanometry, acoustic reflex testing, vestibular evoked myogenic potential (VEMP) testing, distortion product otoacoustic emission (DPOAE) testing, and middle ear exploration in some ears. One ear with LVAS had anacusis. The other 7 ears demonstrated air-bone gaps at the low frequencies, with mean gaps of 51 dB at 250 Hz, 31 dB at 500 Hz, and 12 dB at 1,000 Hz. In these 7 ears with air-bone gaps, LDV showed the umbo velocity to be normal or high normal in all 7; tympanometry was normal in all 6 ears tested; acoustic reflexes were present in 3 of the 4 ears tested; VEMP responses were present in all 3 ears tested; DPOAEs were present in 1 of the 2 ears tested, and exploratory tympanotomy in 1 case showed a normal middle ear. The above data suggest that an air-bone gap in LVAS is not due to disease in the middle ear. The data are consistent with the hypothesis that a large vestibular aqueduct introduces a third mobile window into the inner ear, which can produce an air-bone gap by 1) shunting air-conducted sound away from the cochlea, thus elevating air conduction thresholds, and 2) increasing the difference in impedance between the scala vestibuli side and the scala tympani side of the cochlear partition during bone conduction testing, thus improving thresholds for bone-conducted sound. We conclude that LVAS can present with an air-bone gap that can mimic middle ear disease. Diagnostic testing using acoustic reflexes, VEMPs, DPOAEs, and LDV can help to identify a non-middle ear source for such a gap, thereby avoiding negative middle ear exploration. A large vestibular aqueduct may act as a third mobile window in the inner ear, resulting in an air-bone gap at low frequencies.
Genetic Architecture of Ear Fasciation in Maize (Zea mays) under QTL Scrutiny.
Mendes-Moreira, Pedro; Alves, Mara L; Satovic, Zlatko; Dos Santos, João Pacheco; Santos, João Nina; Souza, João Cândido; Pêgo, Silas E; Hallauer, Arnel R; Vaz Patto, Maria Carlota
2015-01-01
Knowledge of the genes affecting maize ear inflorescence may lead to better grain yield modeling. Maize ear fasciation, defined as abnormal flattened ears with high kernel row number, is a quantitative trait widely present in Portuguese maize landraces. Using a segregating population derived from an ear fasciation contrasting cross (consisting of 149 F2:3 families) we established a two location field trial using a complete randomized block design. Correlations and heritabilities for several ear fasciation-related traits and yield were determined. Quantitative Trait Loci (QTL) involved in the inheritance of those traits were identified and candidate genes for these QTL proposed. Ear fasciation broad-sense heritability was 0.73. Highly significant correlations were found between ear fasciation and some ear and cob diameters and row number traits. For the 23 yield and ear fasciation-related traits, 65 QTL were identified, out of which 11 were detected in both environments, while for the three principal components, five to six QTL were detected per environment. Detected QTL were distributed across 17 genomic regions and explained individually, 8.7% to 22.4% of the individual traits or principal components phenotypic variance. Several candidate genes for these QTL regions were proposed, such as bearded-ear1, branched silkless1, compact plant1, ramosa2, ramosa3, tasselseed4 and terminal ear1. However, many QTL mapped to regions without known candidate genes, indicating potential chromosomal regions not yet targeted for maize ear traits selection. Portuguese maize germplasm represents a valuable source of genes or allelic variants for yield improvement and elucidation of the genetic basis of ear fasciation traits. Future studies should focus on fine mapping of the identified genomic regions with the aim of map-based cloning.
Biomechanical Modeling and Measurement of Blast Injury and Hearing Protection Mechanisms
2015-10-01
12 software into Workbench V. 15 in CFX/ANSYS; 2) building the geometry of the ear model with ossicular chain and cochlear load in CFX; 3...the ear canal to middle ear. The model consists of the ear canal, TM, middle ear ossicles and suspensory ligaments, middle ear cavity, and cochlear ...the TM, ossicles, and ligaments/muscle tendons with the cochlear load applied on the stapes footplate. 17 Fig. 21. Time-history plots of
Challenges in fitting a hearing aid to a severely collapsed ear canal and mixed hearing loss.
Oeding, Kristi; Valente, Michael; Chole, Richard
2012-04-01
Collapsed ear canals typically occur when an outside force, such as a headset for audiometric testing, is present. However, when a collapsed ear canal occurs without external pressure, this creates a challenge not only for performing audiometric testing but also for coupling a hearing aid to the ear canal. This case report highlights the challenges associated with fitting a hearing aid on a patient with a severe anterior-posterior collapsed ear canal with a mixed hearing loss. A 67-yr-old female originally presented to Washington University in St. Louis School of Medicine in 1996 with a long-standing history of bilateral otosclerosis. She had chronic ear infections in the right ear and a severely collapsed ear canal in the left ear and was fit with a bone anchored hearing aid (BAHA®) on the right side in 2003. However, benefit from the BAHA started to decrease due to changes in hearing, and a different hearing solution was needed. It was proposed that a hearing aid be fit to her collapsed left ear canal; however, trying to couple a hearing aid to the collapsed ear canal required unique noncustom earmold solutions. This case study highlights some of the obstacles and potential solutions for coupling a hearing aid to a severely collapsed ear canal. American Academy of Audiology.
Zibrandtsen, I C; Kidmose, P; Christensen, C B; Kjaer, T W
2017-12-01
Ear-EEG is recording of electroencephalography from a small device in the ear. This is the first study to compare ictal and interictal abnormalities recorded with ear-EEG and simultaneous scalp-EEG in an epilepsy monitoring unit. We recorded and compared simultaneous ear-EEG and scalp-EEG from 15 patients with suspected temporal lobe epilepsy. EEGs were compared visually by independent neurophysiologists. Correlation and time-frequency analysis was used to quantify the similarity between ear and scalp electrodes. Spike-averages were used to assess similarity of interictal spikes. There were no differences in sensitivity or specificity for seizure detection. Mean correlation coefficient between ear-EEG and nearest scalp electrode was above 0.6 with a statistically significant decreasing trend with increasing distance away from the ear. Ictal morphology and frequency dynamics can be observed from visual inspection and time-frequency analysis. Spike averages derived from ear-EEG electrodes yield a recognizable spike appearance. Our results suggest that ear-EEG can reliably detect electroencephalographic patterns associated with focal temporal lobe seizures. Interictal spike morphology from sufficiently large temporal spike sources can be sampled using ear-EEG. Ear-EEG is likely to become an important tool in clinical epilepsy monitoring and diagnosis. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
Could ionizing radiation forestall cauliflower ear?
Hwang, K; Kim, C W; Lee, S I; Park, I S; Kim, W C; Loh, J J
2001-02-01
Repeated trauma to the ear very often results in "cauliflower ear." Many methods have been suggested to prevent an injured ear from demonstrating a cauliflowerlike deformity. The principles of treatment are evacuation of the hematoma, control of the reaccumulation of fluid, and maintenance of the cartilage contour. The authors studied the effect of ionizing radiation on deformed rabbit ears induced by repeated trauma. Twenty ears (10 rabbits) were used in the experiment. The animals were divided into four groups (control, preradiation, low dose, and high dose). Hematoma was produced by pounding the lateral side of the auricle 10 times with a 50-g weight at a height of 15 cm. The thickness of the injured and uninjured sites was measured, and histological analysis was performed for each group. The thickness of the ears of the irradiated groups was significantly less than the control group. The authors think that radiation treatment of repeatedly injured ears could prevent ear deformity, and could possibly be an adjunctive form of management of cauliflower ear in addition to hematoma evacuation and compression therapy.
... most common illness in infants and young children. Tinnitus, a roaring in your ears, can be the ... problems in your inner ear; its symptoms include tinnitus and dizziness. Ear barotrauma is an injury to ...
Ear Scaffold Reconstruction Using Ultrasonic Aspirator for Cauliflower Ear.
Hao, Scarlett; Angster, Kristen; Hubbard, Fleesie; Greywoode, Jewel; Vakharia, Kalpesh T
2018-04-01
Untreated auricular hematomas from ear trauma can result in an ear deformation known as cauliflower ear, secondary to fibrosis and new cartilage overgrowth. Cauliflower ear reconstruction has traditionally utilized tools such as a drill or a scalpel in order to improve auricular cosmesis. We present a case report utilizing an ultrasonic aspirator to recontour the fibrosed cartilage of a cauliflower ear. The ultrasonic aspirator has advantages over traditional tools in its ability to provide finely controlled bone removal without damage to surrounding soft tissue. The patient in this case report underwent multistage reconstruction using the ultrasonic aspirator with excellent cosmetic result and patient satisfaction.
Two flaps and Z-plasty technique for correction of longitudinal ear lobe cleft.
Lee, Paik-Kwon; Ju, Hong-Sil; Rhie, Jong-Won; Ahn, Sang-Tae
2005-06-01
Various surgical techniques have been reported for the correction of congenital ear lobe deformities. Our method, the two-flaps-and-Z-plasty technique, for correcting the longitudinal ear lobe cleft is presented. This technique is simple and easy to perform. It enables us to keep the bulkiness of the ear lobe with minimal tissue sacrifice, and to make a shorter operation scar. The small Z-plasty at the free ear lobe margin avoids notching deformity and makes the shape of the ear lobe smoother. The result is satisfactory in terms of matching the contralateral normal ear lobe in shape and symmetry.
Unclassified congenital deformities of the external ear.
Vathulya, Madhubari
2018-01-01
Congenital ear deformities are a common entity. They are found in isolation or as a part of syndrome in patients. They may involve the external, middle or inner ear or in any of these combinations. Three patients of different ages presented with deformities including mirror image duplication of the superior auricle, unclassified deformities of ear lobule (wavy lobule) and deformity of superior auricle with unclassified variety of lateral ear pit. This article highlights that there are further cases of ear deformities that are noticed in the general population who come for cosmetic correction, and hence, there is a need for further modifying the classification of ear deformities.
Middle Ear Infections and Ear Tube Surgery (For Parents)
... Infection? Swimmer's Ear Perforated Eardrum Hearing Impairment Swimmer's Ear (External ... All information on KidsHealth® is for educational purposes only. For specific medical advice, diagnoses, and treatment, ...
Ear pain and its treatment in hypobaric chamber training in the Japan Air Self-Defense Force.
Ohrui, Nobuhiro; Takeuchi, Akihiko; Tong, Andrew; Iwata, Masashi
2008-06-01
We have documented that ear pain is the most prevalent physiologic incident during hypobaric chamber training in the Japan Air Self-Defense Force. Ear pain may increase also in flight in the future because it is closely related to allergic rhinitis. Therefore, it is very important to know the characteristic of ear pain and the efficacy of its treatment. The incidence of ear pain was calculated in each training profile from 1990 to 1998. Type III chamber flight records were further analyzed for the characteristics of ear pain: relationship with a trainee occupational category, time of occurrence of ear pain, and efficacy of treatment. Of 17,935 exposures, 740 trainees (4.1%) had ear pain. Of 7,047 trainees, 429 (6.1%) complained of ear pain especially in Type III, totaling 625 times. Fighter pilots and cargo pilots complained of ear pain one twelfth and one third the number of times, respectively, compared with passengers. Of the 625 episodes, 616 (98.6%) occurred during descent. Three kinds of treatment were administered until the pain was relieved in the following order: Valsalva maneuver, Politzer bag, and decompression. The efficacy rates were 35.8, 92.3, and 83.9%, respectively. Only 5 trainees (0.07%) could not complete training due to ear pain despite treatment. The combination treatment of Valsalva maneuver, Politzer bag, and decompression is very effective for relieving ear pain encountered during hypobaric chamber training. A health specialist needs to understand ear pain and its treatment in hypobaric environment such as aircraft.
Zhou, Guangwei; Schwartz, Lynn Thomas; Gopen, Quinton
2009-02-01
To identify the occurrence of inner ear structural anomalies and conductive hearing loss (CHL) in children with Apert syndrome. Retrospective review. Pediatric tertiary referral center. Twenty pediatric patients with Apert syndrome were found; all patients (38/40 ears) had inner ear anomalies. Computerized tomography of the head/temporal bone, pure-tone (including air and bone conduction) audiometry, and tympanometry. Imaging demonstrating inner ear anomalies, including malformations of the cochlea, dilated vestibule, and/or semicircular canal; audiologic findings of air-bone gap(s). Hearing loss was found in 90% of the patients with Apert syndrome, and 80% of them had CHL. Air-bone gaps were found at all frequencies, with larger gaps at low frequencies. Fifty percent (20/40) of the ears had better than 0 dB hearing level bone conduction thresholds at 250 and/or 500 Hz. Normal middle ear pressure and mobility were found in all ears with intact eardrum. Inner ear anomalies were found in all patients, and 90% of them had bilateral involvement. Most frequently observed inner ear anomalies were dilated vestibule, malformed lateral semicircular canal, and cochlear dysplasia. Children with Apert syndrome may present with significant CHL that cannot be explained by minor middle ear pathologies alone. This conductive loss may be, at least partially, attributed to the inner ear anomalies; however, these structural anomalies are usually not recognized in these patients. Failure to close air-bone gap after surgical intervention may raise the suspicion of inner ear anomalies, and computed tomographic scan of the temporal bone can provide definitive proof.
A morphometric study of the human ear.
Alexander, K Skaria; Stott, David J; Sivakumar, Branavan; Kang, Norbert
2011-01-01
We examined variations in the shape of the human ear according to age, sex and ethnic group with particular attention to ear prominence. 420 volunteers were recruited. Measurements included; head height and length, ear height and axis, antihelix taken off angle, earlobe length and width, ear width at the helical root and tragus. Prominence was measured at the helical root and tragus (conchomastoid angle, conchal bowl depth and helical-mastoid distance). Good symmetry was shown for all measurements. Ethnically Indian volunteers had the largest ears (both length and width), followed by Caucasians, and Afro-Caribbeans. This trend was significant in males (p<0.001), but not significant in females (p=0.087). Ears increased in size throughout life. Subjectively, only 2% of volunteers felt their ears were prominent compared to 10% in the opinion of the principal investigator. No objective measurements were identified that accurately predicted subjective perceptions of prominence. We found consistent trends in ear morphology depending on ethnic group, age and sex. Our study was unable to define an objective method for assessing ear prominence. Decisions about what constitutes a prominent ear should be left to personal and aesthetic choice. Copyright © 2010 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Scanning Thin-Sheet Laser Imaging Microscopy Elucidates Details on Mouse Ear Development
Kopecky, Benjamin; Johnson, Shane; Schmitz, Heather; Santi, Peter; Fritzsch, Bernd
2016-01-01
Background The mammalian inner ear is transformed from a flat placode into a three-dimensional (3D) structure with six sensory epithelia that allow for the perception of sound and both linear and angular acceleration. While hearing and balance problems are typically considered to be adult onset diseases, they may arise as a developmental perturbation to the developing ear. Future prevention of hearing or balance loss requires an understanding of how closely genetic mutations in model organisms reflect the human case, necessitating an objective multidimensional comparison of mouse ears with human ears that have comparable mutations in the same gene. Results Here, we present improved 3D analyses of normal murine ears during embryonic development using optical sections obtained through Thin-Sheet Laser Imaging Microscopy. We chronicle the transformation of an undifferentiated otic vesicle between mouse embryonic day 11.5 to a fully differentiated inner ear at postnatal day 15. Conclusions Our analysis of ear development provides new insights into ear development, enables unique perspectives into the complex development of the ear, and allows for the first full quantification of volumetric and linear aspects of ear growth. Our data provide the framework for future analysis of mutant phenotypes that are currently under-appreciated using only two dimensional renderings. PMID:22271591
Scanning thin-sheet laser imaging microscopy elucidates details on mouse ear development.
Kopecky, Benjamin; Johnson, Shane; Schmitz, Heather; Santi, Peter; Fritzsch, Bernd
2012-03-01
The mammalian inner ear is transformed from a flat placode into a three-dimensional (3D) structure with six sensory epithelia that allow for the perception of sound and both linear and angular acceleration. While hearing and balance problems are typically considered to be adult onset diseases, they may arise as a developmental perturbation to the developing ear. Future prevention of hearing or balance loss requires an understanding of how closely genetic mutations in model organisms reflect the human case, necessitating an objective multidimensional comparison of mouse ears with human ears that have comparable mutations in the same gene. Here, we present improved 3D analyses of normal murine ears during embryonic development using optical sections obtained through Thin-Sheet Laser Imaging Microscopy. We chronicle the transformation of an undifferentiated otic vesicle between mouse embryonic day 11.5 to a fully differentiated inner ear at postnatal day 15. Our analysis of ear development provides new insights into ear development, enables unique perspectives into the complex development of the ear, and allows for the first full quantification of volumetric and linear aspects of ear growth. Our data provide the framework for future analysis of mutant phenotypes that are currently under-appreciated using only two dimensional renderings. Copyright © 2012 Wiley Periodicals, Inc.
External Otitis (Swimmer's Ear)
... Debris removal, antibiotic ear drops, keeping water and cotton swabs out of the ear, and pain relievers ... Injuring the ear canal while cleaning it (using cotton swabs) or getting water or irritants, such as ...
... secretions from the middle ear Swelling, inflammation and mucus in the eustachian tubes from an upper respiratory ... your baby for at least six months. Breast milk contains antibodies that may offer protection from ear ...
49 CFR Appendix C to Part 227 - Audiometric Baseline Revision
Code of Federal Regulations, 2011 CFR
2011-10-01
... FRA STS. The two ears are examined separately and independently for improvement and for worsening. If one ear meets the criteria for revision of baseline, then the baseline is revised for that ear only. Therefore, if the two ears show different hearing trends, the baseline for the left ear may be from one test...
49 CFR Appendix C to Part 227 - Audiometric Baseline Revision
Code of Federal Regulations, 2012 CFR
2012-10-01
... FRA STS. The two ears are examined separately and independently for improvement and for worsening. If one ear meets the criteria for revision of baseline, then the baseline is revised for that ear only. Therefore, if the two ears show different hearing trends, the baseline for the left ear may be from one test...
... Inserting something into the ear. Things like a cotton swab, fingernail, or pencil can scratch the ear ... Never stick anything in their ears — not even cotton swabs or their fingers. Regular bathing should be ...
Can I Prevent Ear Infections When My Child Swims? (For Parents)
... Ear Your Ears Perforated Eardrum What's Earwax? Swimmer's Ear (External ... All information on KidsHealth® is for educational purposes only. For specific medical advice, diagnoses, and treatment, ...
40 CFR Appendix A to Part 211 - Compliance Audit Testing Report
Code of Federal Regulations, 2011 CFR
2011-07-01
... Appendix A to Part 211 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS PRODUCT NOISE LABELING Pt. 211, App. A Appendix A to Part 211—Compliance Audit Testing... 250 500 1000 2000 3150 4000 6300 8000 Noise Reduction Rating: If replacement hearing protector was...
33 CFR 142.27 - Eye and face protection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Eye and face protection. 142.27... Eye and face protection. (a) Personnel engaged in or observing welding, grinding, machining, chipping, handling hazardous materials, or acetylene burning or cutting shall wear the eye and face protector...
33 CFR 142.27 - Eye and face protection.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Eye and face protection. 142.27... Eye and face protection. (a) Personnel engaged in or observing welding, grinding, machining, chipping, handling hazardous materials, or acetylene burning or cutting shall wear the eye and face protector...
Capacity Building as an Answer to Piracy in the Horn of Africa
2010-12-01
reliable professional choice .17 Also, many Somali pirates consider themselves protectors of their waters against foreign trawlers that illegally fish.18...the area. Many young Somali males view piracy as an optional professional choice .23 Finally, two important contributors to the rise in piracy in the
46 CFR 90.05-10 - Application to vessels on an international voyage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... a protectorate or mandate, whose international relations are the responsibility of a contracting... 46 Shipping 4 2010-10-01 2010-10-01 false Application to vessels on an international voyage. 90.05... MISCELLANEOUS VESSELS GENERAL PROVISIONS Application § 90.05-10 Application to vessels on an international...
7 CFR 1755.506 - Aerial wire services
Code of Federal Regulations, 2010 CFR
2010-01-01
.../Orange or White Orange 3 White/Green or White Green 4 White/Brown or White Brown 5 White/Slate or White... station protectors. (p) When it is necessary to avoid intervening obstacles between a pole and a building... lines to buildings shall follow the shortest feasible route commensurate with the requirements of...
21 CFR 876.5900 - Ostomy pouch and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
....5900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... created opening of the small intestine, large intestine, or the ureter on the surface of the body). This... bag, ostomy drainage bag with adhesive, stomal bag, ostomy protector, and the ostomy size selector...
21 CFR 876.5900 - Ostomy pouch and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
....5900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... created opening of the small intestine, large intestine, or the ureter on the surface of the body). This... bag, ostomy drainage bag with adhesive, stomal bag, ostomy protector, and the ostomy size selector...
21 CFR 876.5900 - Ostomy pouch and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
....5900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... created opening of the small intestine, large intestine, or the ureter on the surface of the body). This... bag, ostomy drainage bag with adhesive, stomal bag, ostomy protector, and the ostomy size selector...
21 CFR 876.5900 - Ostomy pouch and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
....5900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... created opening of the small intestine, large intestine, or the ureter on the surface of the body). This... bag, ostomy drainage bag with adhesive, stomal bag, ostomy protector, and the ostomy size selector...
Improve Carpet Life with Proper Installation.
ERIC Educational Resources Information Center
Grogan, Ralph
1998-01-01
Provides guidance on ways to extend carpet life in educational facilities by paying attention to the details of carpeting installation. Issues to consider include choosing carpeting to meet specific usage requirements, are fiber protectorants used, is the installation properly done by qualified installers, and is moisture testing done prior to…
33 CFR 142.27 - Eye and face protection.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Eye and face protection. 142.27... Eye and face protection. (a) Personnel engaged in or observing welding, grinding, machining, chipping, handling hazardous materials, or acetylene burning or cutting shall wear the eye and face protector...
33 CFR 142.27 - Eye and face protection.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Eye and face protection. 142.27... Eye and face protection. (a) Personnel engaged in or observing welding, grinding, machining, chipping, handling hazardous materials, or acetylene burning or cutting shall wear the eye and face protector...
33 CFR 142.27 - Eye and face protection.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Eye and face protection. 142.27... Eye and face protection. (a) Personnel engaged in or observing welding, grinding, machining, chipping, handling hazardous materials, or acetylene burning or cutting shall wear the eye and face protector...
... a waterproof plastic cast protector instead of plastic bags. You can buy this at a drugstore. Keep the cast completely out of the water by propping it up on the side of the tub. If the cast or liner gets splashed, gently blow air into it from a hair dryer on the ...
Expansion method in secondary total ear reconstruction for undesirable reconstructed ear.
Liu, Tun; Hu, Jintian; Zhou, Xu; Zhang, Qingguo
2014-09-01
Ear reconstruction by autologous costal cartilage grafting is the most widely applied technique with fewer complications. However, undesirable ear reconstruction brings more problems to plastic surgeons. Some authors resort to free flap or osseointegration technique with prosthetic ear. In this article, we introduce a secondary total ear reconstruction with expanded skin flap method. From July 2010 to April 2012, 7 cases of undesirable ear reconstruction were repaired by tissue expansion method. Procedures including removal of previous cartilage framework, soft tissue expander insertion, and second stage of cartilage framework insertion were performed to each case regarding their local conditions. The follow-up time ranged from 6 months to 2.5 years. All of the cases recovered well with good 3-dimensional forms, symmetrical auriculocephalic angle, and stable fixation. All these evidence showed that this novel expansion method is safe, stable, and less traumatic for secondary total ear reconstruction. With sufficient expanded skin flap and refabricated cartilage framework, lifelike appearance of reconstructed ear could be acquired without causing additional injury.
Patel, Tirth R; Shahin, Antoine J; Bhat, Jyoti; Welling, D Bradley; Moberly, Aaron C
2016-10-01
We describe a novel use of cortical auditory evoked potentials in the preoperative workup to determine ear candidacy for cochlear implantation. A 71-year-old male was evaluated who had a long-deafened right ear, had never worn a hearing aid in that ear, and relied heavily on use of a left-sided hearing aid. Electroencephalographic testing was performed using free field auditory stimulation of each ear independently with pure tones at 1000 and 2000 Hz at approximately 10 dB above pure-tone thresholds for each frequency and for each ear. Mature cortical potentials were identified through auditory stimulation of the long-deafened ear. The patient underwent successful implantation of that ear. He experienced progressively improving aided pure-tone thresholds and binaural speech recognition benefit (AzBio score of 74%). Findings suggest that use of cortical auditory evoked potentials may serve a preoperative role in ear selection prior to cochlear implantation. © The Author(s) 2016.
[Adaptability of sweet corn ears to a frozen process].
Ramírez Matheus, Alejandra O; Martínez, Norelkys Maribel; de Bertorelli, Ligia O; De Venanzi, Frank
2004-12-01
The effects of frozen condition on the quality of three sweet corn ears (2038, 2010, 2004) and the pattern (Bonanza), were evaluated. Biometrics characteristics like ear size, ear diameter, row and kernel deep were measured as well as chemical and physical measurement in fresh and frozen states. The corn ears were frozen at -95 degrees C by 7 minutes. The yield and stability of the frozen ears were evaluated at 45 and 90 days of frozen storage (-18 degrees C). The average commercial yield as frozen corn ear for all the hybrids was 54.2%. The industry has a similar value range of 48% to 54%. The ear size average was 21.57 cm, row number was 15, ear diameter 45.54 mm and the kernel corn deep was 8.57 mm. All these measurements were found not different from commercial values found for the industry. All corn samples evaluated showed good stability despites the frozen processing and storage. Hybrid 2038 ranked higher in quality.
Can you hear me now? Understanding vertebrate middle ear development
Chapman, Susan Caroline
2010-01-01
The middle ear is a composite organ formed from all three germ layers and the neural crest. It provides the link between the outside world and the inner ear, where sound is transduced and routed to the brain for processing. Extensive classical and modern studies have described the complex morphology and origin of the middle ear. Non-mammalian vertebrates have a single ossicle, the columella. Mammals have three functionally equivalent ossicles, designated the malleus, incus and stapes. In this review, I focus on the role of genes known to function in the middle ear. Genetic studies are beginning to unravel the induction and patterning of the multiple middle ear elements including the tympanum, skeletal elements, the air-filled cavity, and the insertion point into the inner ear oval window. Future studies that elucidate the integrated spatio-temporal signaling mechanisms required to pattern the middle ear organ system are needed. The longer-term translational benefits of understanding normal and abnormal ear development will have a direct impact on human health outcomes. PMID:21196256
Identifying position, visibility, dimensions, and angulation of the ear.
Mohamed, Kasim; Christian, Jayanth; Jeyapalan, Karthigeyan; Natarajan, Shanmuganathan; Banu, Fathima; Veeravalli, Padmanabhan T
2014-01-01
We selected 254 subjects between the ages of 18 and 30 yr to assess the ear position, angulations of the ear in relation to the nose, visibility from the frontal view, and dimensions of the ear by using various anthropometric points of the face. Subjects were divided into four groups based on facial form. A reference plane indicator, facial topographical measurements, metal ruler, and digital photography were used. While considering the position of the ear, in all facial forms except square tapering, the most samples showed a tendency for the subaurale being in line with subnasale. Regression analysis showed a tendency to gnathion distance is the most dependent variable with length of the ear kept as a constant predictor, while both interalar distance and exocanthion to endocanthion distance correlate highly significantly to the width of the ear. In all subjects, the visibility of the ear when viewed from the front was an average of 1.5 mm. Regardless of facial form, ear angulation was generally less than nose angulation.
Mahdavi, Mohammad Ebrahim; Pourbakht, Akram; Parand, Akram; Jalaie, Shohreh
2018-03-01
Evaluation of dichotic listening to digits is a common part of many studies for diagnosis and managing auditory processing disorders in children. Previous researchers have verified test-retest relative reliability of dichotic digits results in normal children and adults. However, detecting intervention-related changes in the ear scores after dichotic listening training requires information regarding trial-to-trial typical variation of individual ear scores that is estimated using indices of absolute reliability. Previous studies have not addressed absolute reliability of dichotic listening results. To compare the results of the Persian randomized dichotic digits test (PRDDT) and its relative and absolute indices of reliability between typical achieving (TA) and learning-disabled (LD) children. A repeated measures observational study. Fifteen LD children were recruited from a previously performed study with age range of 7-12 yr. The control group consisted of 15 TA schoolchildren with age range of 8-11 yr. The Persian randomized dichotic digits test was administered on the children under free recall condition in two test sessions 7-12 days apart. We compared the average of the ear scores and ear advantage between TA and LD children. Relative indices of reliability included Pearson's correlation and intraclass correlation (ICC 2,1 ) coefficients and absolute reliability was evaluated by calculation of standard error of measurement (SEM) and minimal detectable change (MDC) using the raw ear scores. The Pearson correlation coefficient indicated that in both groups of children the ear scores of test and retest sessions were strongly and positively (greater than +0.8) correlated. The ear scores showed excellent ICC coefficient of consistency (0.78-0.82) and fair to excellent ICC coefficient of absolute agreement (0.62-0.74) in TA children and excellent ICC coefficients of consistency and absolute agreement in LD children (0.76-0.87). SEM and SEM% of the ear scores in TA children were 1.46 and 1.44% for the right ear and 4.68 and 5.47% for the left ear. SEM and SEM% of the ear scores in LD children were 4.55 and 5.88% for the right ear to 7.56 and 12.81% for the left ear. MDC and MDC% of the ear scores in TA children varied from 4.03 and 3.99% for the right ear to 12.93 and 15.13% for the left ear. MDC and MDC% of the ear scores in LD children varied from 12.57 and 16.25% for the right ear to 20.89 and 35.39% for the left ear. The LD children indicated test-retest relative reliability as high as TA children in the ear scores measured by PRDDT. However, within-subject variations of the ear scores calculated by indices of absolute reliability were considerably higher in LD children versus TA children. The results of the current study could have implications for detecting real training-related changes in the ear scores. American Academy of Audiology
Mielczarek, Marzena; Konopka, Wieslaw; Olszewski, Jurek
2013-02-01
The aim of the study was to evaluate the effectiveness of electrical stimulations of the hearing organ in tinnitus treatment adapting the frequency of stimulation according to tinnitus frequency, to assess the influence of cervical spine kinesitherapy on tinnitus, as well as to evaluate hearing after electrical stimulations alone and together with cervical spine kinesitherapy. The study comprised 80 tinnitus, sensorineural hearing loss patients (119 tinnitus ears) divided into two groups. In group I (n - 58 tinnitus ears) electrical stimulation of the hearing organ was performed, in group II (n - 61 tinnitus ears) electrical stimulation together with cervical spine kinesitherapy. Hydrotransmissive, selective electrical stimulations were conducted using direct, rectangular current. The passive electrode was placed on the forehead, the active--a silver probe--was immersed in the external ear canal in 0.9% saline solution. The treatment involved fifteen applications of electrical stimulations (each lasted for 4 min) administered three or four times a week (whole treatment lasted approximately 30 days). The evaluation of the results considered a case history (change from permanent to temporary tinnitus), questionnaires (the increase/decrease of the total points) and the audiometric evaluation of hearing level. Before the treatment, group I comprised 51 ears (87.93%) with permanent, and 7 ears (12.07%) with temporary tinnitus; group II - 55 ears (90.17%) with permanent and 6 ears (9.83%) with temporary tinnitus. After the treatment, in both groups the number of ears with permanent tinnitus decreased considerably obtaining the pauses or disappearing of tinnitus. Directly after the treatment, group I comprised 25 ears (43.11%) with permanent, and 10 ears (17.24%) with temporary tinnitus, in 23 ears (39.65%) tinnitus disappeared; group II - 33 ears (54.1%) with permanent and 11 ears (18.03%) with temporary tinnitus, in 17 ears (27.87%) tinnitus disappeared. Regarding questionnaires, improvement was observed in group I - in 43.11% of ears, in group II - 32.8%. In both groups audiometric improvement of hearing was recognized. (1) Electrical stimulation of the hearing organ, with the application of current frequencies according to tinnitus frequencies (selective electrical stimulation), was an efficient method in severe tinnitus treatment. (2) Cervical spine kinesitherapy in the treatment of tinnitus, using electrical stimulation, did not have any supporting influence. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Preserved Acoustic Hearing in Cochlear Implantation Improves Speech Perception
Sheffield, Sterling W.; Jahn, Kelly; Gifford, René H.
2015-01-01
Background With improved surgical techniques and electrode design, an increasing number of cochlear implant (CI) recipients have preserved acoustic hearing in the implanted ear, thereby resulting in bilateral acoustic hearing. There are currently no guidelines, however, for clinicians with respect to audio-metric criteria and the recommendation of amplification in the implanted ear. The acoustic bandwidth necessary to obtain speech perception benefit from acoustic hearing in the implanted ear is unknown. Additionally, it is important to determine if, and in which listening environments, acoustic hearing in both ears provides more benefit than hearing in just one ear, even with limited residual hearing. Purpose The purposes of this study were to (1) determine whether acoustic hearing in an ear with a CI provides as much speech perception benefit as an equivalent bandwidth of acoustic hearing in the non-implanted ear, and (2) determine whether acoustic hearing in both ears provides more benefit than hearing in just one ear. Research Design A repeated-measures, within-participant design was used to compare performance across listening conditions. Study Sample Seven adults with CIs and bilateral residual acoustic hearing (hearing preservation) were recruited for the study. Data Collection and Analysis Consonant-nucleus-consonant word recognition was tested in four conditions: CI alone, CI + acoustic hearing in the nonimplanted ear, CI + acoustic hearing in the implanted ear, and CI + bilateral acoustic hearing. A series of low-pass filters were used to examine the effects of acoustic bandwidth through an insert earphone with amplification. Benefit was defined as the difference among conditions. The benefit of bilateral acoustic hearing was tested in both diffuse and single-source background noise. Results were analyzed using repeated-measures analysis of variance. Results Similar benefit was obtained for equivalent acoustic frequency bandwidth in either ear. Acoustic hearing in the nonimplanted ear provided more benefit than the implanted ear only in the wideband condition, most likely because of better audiometric thresholds (>500 Hz) in the nonimplanted ear. Bilateral acoustic hearing provided more benefit than unilateral hearing in either ear alone, but only in diffuse background noise. Conclusions Results support use of amplification in the implanted ear if residual hearing is present. The benefit of bilateral acoustic hearing (hearing preservation) should not be tested in quiet or with spatially coincident speech and noise, but rather in spatially separated speech and noise (e.g., diffuse background noise). PMID:25690775
... Eardrum Taking Care of Your Ears Can Loud Music Hurt My Ears? Your Ears What's Earwax? How Do Pain Relievers Work? View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...
Laser-assisted tympanostomy (LAT) in adult individuals
NASA Astrophysics Data System (ADS)
Prokopakis, E. P.; Lachanas, V. A.; Helidonis, Emmanuel S.; Velegrakis, G.
2004-06-01
Objectives: To assess outcome, in adult individuals undergone Laser Assisted Tympanostomy (LAT) without ventilation tube placement. Method: LAT was performed on a total of 95 ears (72 individuals). Indications included serous otitis media with effusion (44 ears/31 patients), eustachian tube dysfunction (32 ears/24 patients), acute otitis media (13 ears/11 patients), and endoscopic visualization of the middle ear (6 ears/6 patients). Results: Middle ear disease was resolved after the closure of tympanostomy in 48% of patients with serous otitis media with effusion. In 78% of patients with Eustachian tube dysfunction symptoms were diminished. All patients with acute otitis media had a satisfactory outcome. LAT was found quite effective in patients undergoing middle ear endoscopy. Conclusion: LAT without ventilation tubes provides a safe alternative surgical option in adult patients in certain cases. The selection criteria for this procedure are addressed in detail.
Structures that Contribute to Middle-Ear Admittance in Chinchilla
Rosowski, John J.; Ravicz, Michael E.; Songer, Jocelyn E.
2009-01-01
We describe measurements of middle-ear input admittance in chinchillas (Chinchilla lanigera) before and after various manipulations that define the contributions of different middle-ear components to function. The chinchilla’s middle-ear air spaces have a large effect on the low-frequency compliance of the middle ear, and removing the influences of these spaces reveals a highly admittant tympanic membrane and ossicular chain. Measurements of the admittance of the air spaces reveal that the high-degree of segmentation of these spaces has only a small effect on the admittance. Draining the cochlea further increases the middle-ear admittance at low frequencies and removes a low-frequency (less than 300 Hz) level dependence in the admittance. Spontaneous or sound-driven contractions of the middle-ear muscles in deeply anesthetized animals were associated with significant changes in middle-ear admittance. PMID:16944166
NASA Technical Reports Server (NTRS)
Popper, Arthur N.; Edds-Walton, Peggy L.
1995-01-01
A body of literature suggests that the Mauthner cell startle response can be elicited by stimulation of the ear. While we know that there are projections to the M-cell from the ear, the specific endorgan(s) of the ear projecting to the M-cell are not known. Moreover, there are many reasons to question whether there is one pattern of inner ear to M-cell connection or whether the endorgan(s) projection to the M-cell varies in species that have different hearing capabilities of hearing structures. In this paper, we briefly review the structure of fish ears, with an emphasis on structural regionalization within the ear. We also review the central projections of the ear, along with a discussion of the limited data on projections to the M-cell.
Does ear endoscopy provide advantages in the outpatient management of open mastoidectomy cavities?
Freire, Gustavo Subtil Magalhães; Sampaio, Andre Luiz Lopes; Lopes, Rafaela Aquino Fernandes; Nakanishi, Márcio; de Oliveira, Carlos Augusto Costa Pires
2018-01-01
To evaluate the use of ear endoscopy in the postoperative management of open mastoidectomy cavities, and to test whether ear endoscopy improves inspection and cleaning compared with ear microscopy. Prospective study. Thirty-two ears were divided into two groups: group 1, examination and cleaning of mastoid cavities under endoscopic visualization after microscopic standard ear cleaning; group 2, examination and cleaning of mastoid cavities under microscopic visualization after endoscope-assisted ear cleaning. We assessed the ability of each method to provide exposure and facilitate cleaning, comparing the benefits of microscopy and endoscopy when used sequentially and vice-versa. Endoscopy provided additional benefits for exposure in 61.1% of cases and cleaning in 66.7%. Microscopy provided no additional benefits in terms of exposure in any case, and provided added benefit for cleaning in only 21.4% of cases. For outpatient postoperative care of open mastoidectomy cavities, ear endoscopy provides greater benefit over ear microscopy than vice-versa. In over half of all cases, endoscopy was able to expose areas not visualized under the microscope. Furthermore, in two-thirds of cases, endoscopy enabled removal of material that could not be cleared under microscopy. Ear endoscopy was superior to microscopy in terms of enabling exposure and cleaning of hard-to-reach sites, due to its wider field of vision. Ear endoscopy is a feasible technique for the postoperative management of open mastoidectomy cavities. Ear endoscopy provided superior advantages in terms of exposure and aural cleaning compared with microscopy.
Clinical Investigation and Mechanism of Air-Bone Gaps in LargeVestibular Aqueduct Syndrome
Merchant, Saumil N.; Nakajima, Hideko H.; Halpin, Christopher; Nadol, Joseph B.; Lee, Daniel J.; Innis, William P.; Curtin, Hugh; Rosowski, John J.
2008-01-01
Objectives Patients with large vestibular aqueduct syndrome (LVAS) often demonstrate an air-bone gap at the low frequencies on audiometric testing. The mechanism causing such a gap has not been well elucidated. We investigated middle ear sound transmission in patients with LVAS, and present a hypothesis to explain the air-bone gap. Methods Observations were made on 8 ears from 5 individuals with LVAS. The diagnosis of LVAS was made by computed tomography in all cases. Investigations included standard audiometry and measurements of umbo velocity by laser Doppler vibrometry (LDV) in all cases, as well as tympanometry, acoustic reflex testing, vestibular evoked myogenic potential (VEMP) testing, distortion product otoacoustic emission (DPOAE) testing, and middle ear exploration in some ears. Results One ear with LVAS had anacusis. The other 7 ears demonstrated air-bone gaps at the low frequencies, with mean gaps of 51 dB at 250 Hz, 31 dB at 500 Hz, and 12 dB at 1,000 Hz. In these 7 ears with air-bone gaps, LDV showed the umbo velocity to be normal or high normal in all 7; tympanometry was normal in all 6 ears tested; acoustic reflexes were present in 3 of the 4 ears tested; VEMP responses were present in all 3 ears tested; DPOAEs were present in 1 of the 2 ears tested, and exploratory tympanotomy in 1 case showed a normal middle ear. The above data suggest that an air-bone gap in LVAS is not due to disease in the middle ear. The data are consistent with the hypothesis that a large vestibular aqueduct introduces a third mobile window into the inner ear, which can produce an air-bone gap by 1) shunting air-conducted sound away from the cochlea, thus elevating air conduction thresholds, and 2) increasing the difference in impedance between the scala vestibuli side and the scala tympani side of the cochlear partition during bone conduction testing, thus improving thresholds for bone-conducted sound. Conclusions We conclude that LVAS can present with an air-bone gap that can mimic middle ear disease. Diagnostic testing using acoustic reflexes, VEMPs, DPOAEs, and LDV can help to identify a non–middle ear source for such a gap, thereby avoiding negative middle ear exploration. A large vestibular aqueduct may act as a third mobile window in the inner ear, resulting in an air-bone gap at low frequencies. PMID:17727085
Listening to Nature's orchestra with peculiar ears
NASA Astrophysics Data System (ADS)
Yager, David D.
2003-04-01
Insects use hearing for the crucial tasks of communicating with conspecifics and avoiding predators. Although all are based on the same acoustic principles, the diversity of insect ears is staggering and instructive. For instance, a South African grasshopper demonstrates that hearing conspecific calls is possible over distances 1 km with ears that do not have tympana. Actually, these creatures have six pairs of ears that play different roles in behavior. In numerical contrast, praying mantises have just a single ear in the ventral midline. The ear is very effective at detecting ultrasonic bat cries. However, the bioacoustics of sound transduction by two tympana facing each other in a deep, narrow slit is a puzzle. Tachinid flies demonstrate that directional hearing at 5 kHz is possible with a pair of ears fused together to give a total size of 1 mm. The ears are under the fly's chin. Hawk moths have their ears built into their mouthparts and the tympanum is more like a hollow ball than the usual membrane. As an apt last example, cicada ears are actually part of the orchestra: their tympana function both in sound reception and sound production.
Incorporating anthropometry into design of ear-related products.
Liu, Bor-Shong
2008-01-01
To achieve mass customization and collaborative product design, human factors and ergonomics should play a key development role. The purpose of this study was to provide product designers with the anthropometic dimensions of outer ears for different demographic data, including gender and age. The second purpose was to compare the dimensions of various ear-related products (i.e., earphone, bluetooth earphone and ear-cup earphone) with the anthropometic database and recommend appropriate solutions for design. Two hundred subjects aged 20-59 was selected for this study and divided into four age stratifications. Further, three different dimensions of the outer ear (i.e., the earhole length, the ear connection length and the length of the pinna) were measured by superimposed grid photographic technique. The analysis of variance (ANOVA) was used to investigate the effects of gender, and age on ear dimensions. The results showed that all ear dimensions had significant gender effects. A comparison between the anthropometric dimensions and those of current products revealed that most current ear-related products need to be redesigned using anthropometric data. The shapes of earhole and pinna are not circular. Consequently, ear products need to be elongated so that users may feel more comfortably and not have the product slip off easily.
Structure and function of the mammalian middle ear. I: Large middle ears in small desert mammals.
Mason, Matthew J
2016-02-01
Many species of small desert mammals are known to have expanded auditory bullae. The ears of gerbils and heteromyids have been well described, but much less is known about the middle ear anatomy of other desert mammals. In this study, the middle ears of three gerbils (Meriones, Desmodillus and Gerbillurus), two jerboas (Jaculus) and two sengis (elephant-shrews: Macroscelides and Elephantulus) were examined and compared, using micro-computed tomography and light microscopy. Middle ear cavity expansion has occurred in members of all three groups, apparently in association with an essentially 'freely mobile' ossicular morphology and the development of bony tubes for the middle ear arteries. Cavity expansion can occur in different ways, resulting in different subcavity patterns even between different species of gerbils. Having enlarged middle ear cavities aids low-frequency audition, and several adaptive advantages of low-frequency hearing to small desert mammals have been proposed. However, while Macroscelides was found here to have middle ear cavities so large that together they exceed brain volume, the bullae of Elephantulus are considerably smaller. Why middle ear cavities are enlarged in some desert species but not others remains unclear, but it may relate to microhabitat. © 2015 Anatomical Society.
Prenatal evaluation of the middle ear and diagnosis of middle ear hypoplasia using MRI.
Katorza, Eldad; Nahama-Allouche, Catherine; Castaigne, Vanina; Gonzales, Marie; Galliani, Eva; Marlin, Sandrine; Jouannic, Jean-Marie; Rosenblatt, Jonathan; le Pointe, Hubert Ducou; Garel, Catherine
2011-05-01
Analysis of the middle ear with fetal MRI has not been previously reported. To show the contribution of fetal MRI to middle ear imaging. The tympanic cavity was evaluated in 108 fetal cerebral MRI examinations (facial and/or cerebral malformation excluded) and in two cases, one of Treacher Collins syndrome (case 1) and the other of oculo-auriculo-vertebral (OUV) spectrum (case 2) with middle ear hypoplasia identified by MRI at 27 and 36 weeks' gestation, respectively. In all 108 fetuses (mean gestational age 32.5 weeks), the tympanic cavity and T2 hypointensity related to the ossicles were well visualised on both sides. Case 1 had micro/retrognathia and bilateral external ear deformity and case 2 had retrognathism with a left low-set and deformed ear. MRI made it possible to recognize the marked hypoplasia of the tympanic cavity, which was bilateral in case 1 and unilateral in case 2. Both syndromes are characterized by craniofacial abnormalities including middle ear hypoplasia, which cannot be diagnosed with US. The middle ear cavity can be visualized with fetal MRI. We emphasize the use of this imaging modality in the diagnosis of middle ear hypoplasia.
Efficacy of naturopathic extracts in the management of ear pain associated with acute otitis media.
Sarrell, E M; Mandelberg, A; Cohen, H A
2001-07-01
To determine the efficacy and tolerance of Otikon Otic Solution (Healthy-On Ltd, Petach-Tikva, Israel), a naturopathic herbal extract (containing Allium sativum, Verbascum thapsus, Calendula flores, and Hypericum perforatum in olive oil), compared with Anaesthetic (Vitamed Pharmaceutical Ltd, Benyamina, Israel) ear drops (containing ametocaine and phenazone in glycerin) in the management of ear pain associated with acute otitis media (AOM). Children between the ages of 6 and 18 years who experienced ear pain (otalgia) and who were diagnosed with eardrum problems associated with AOM were randomly assigned to be treated with Otikon or Anaesthetic ear drops, which were instilled into the external canal(s) of the affected ear(s). Ear pain was assessed using 2 visual analog scales: a linear scale and a color scale. Pain assessment took place throughout the course of 3 days. The mean score of pain reduction was used to measure outcome. Primary pediatric community ambulatory centers. One hundred three children aged 6 to 18 years who were diagnosed with otalgia associated with AOM. Each of the 2 treatment groups were comparable on the basis of age, sex, laterality of AOM, and the effectiveness of ameliorating symptoms of otalgia. The 2 groups were also comparable to each other in the initial ear pain score and in the scores at each application of Otikon or Anaesthetic drops. There was a statistically significant improvement in ear pain score throughout the course of the study period (P =.007). Otikon, an ear drop formulation of naturopathic origin, is as effective as Anaesthetic ear drops and was proven appropriate for the management of AOM-associated ear pain.
Ear Aesthetics: Investigation by the Use of an Online Viral Survey.
Steele, Jessica; Farmer, Eleanor; O'Hara, Justine; Bulstrode, Neil
2017-03-01
The ear is a key facial feature and yet few studies have previously assessed ear aesthetics. This study aimed to assess the anatomical components of the ear that have the greatest impact on the perception of ear aesthetics. Three photographs of a male adult ear (close-up, lateral, posterior) were digitally manipulated such that in each, 1 anatomical element of the ear was either enlarged or reduced. A complete set of 16 photographs including a repeat of the original ear as a control were randomized and entered into an online survey that required respondents to rate the attractiveness of each ear on a scale of 1 (least attractive) to 10 (most attractive). The survey was disseminated using email and social media. A total of 248 responses were received, 155 women and 92 men. Respondents were grouped by demographics of age and occupation. Reducing (R) or enlarging (E) the helix (R, P = 0.0256; E, P = 0.003), concha (R, P = 0.0002; E, P = <0.0001) and lobule (R, P = 0.0006; E, P < 0.0001) had a significant effect on ratings of attractiveness. Altering the tragus had no significant effect (R, P = 0.448; E, P = 0.201). In lateral view, raising the height of the ear had a significant effect (P = <0.0001) but not in lowering the height (P = 0.3038). Increasing and decreasing the projection of the ears both had a significant effect (P < 0.0001). The results of this study have provided useful evidence regarding the anatomical components of the ear that have the greatest effect on ear aesthetics. Furthermore, this study has proven the usefulness of conducting research using viral online surveys.
Moore, A Russell; Allender, Matthew C; Mitchell, Mark A; MacNeill, Amy L
2015-01-15
To critically evaluate plasma fibrinogen concentration as a diagnostic indicator of inflammation in red-eared sliders (Trachemys scripta elegans). Prospective induced-disease model and prospective cross-sectional study. Plasma samples from 12 purpose-bred red-eared sliders and 153 farm-raised red-eared sliders. A modification of the Jacobsson method was developed to measure fibrinogen concentration in platelet-poor plasma from red-eared sliders. Purpose-bred turtles had been inoculated with a ranavirus (n = 4) or sterile PBS solution (8) as part of another study. Farm-raised red-eared sliders were categorized as healthy (n = 138) or overtly ill (15) on the basis of physical examination findings at the time of blood sample collection. Samples from 124 of the 138 healthy red-eared sliders were used to establish a fibrinogen concentration reference interval as measured by the modified Jacobsson method. Fibrinogen concentrations in ranavirus-infected and physically ill turtles were compared with those of healthy turtles to determine whether fibrinogen concentration would be a useful diagnostic indicator of inflammation in red-eared sliders. The modified Jacobsson method was reliably used to measure fibrinogen concentration. The fibrinogen concentration reference interval from healthy reproductively active female red-eared sliders was right skewed. Fibrinogen concentration did not differ significantly between healthy red-eared sliders and ranavirus-infected or overtly ill red-eared sliders. A reference interval for red-eared slider plasma fibrinogen concentration was established and partitioned by sex to account for considerable right skewing observed for females. Fibrinogen concentration was not a useful indicator of inflammation in red-eared sliders with ranavirus infection or other overt illnesses.
Ghanpur, Asheesh Dora; Nayak, Dipak Ranjan; Chawla, Kiran; Shashidhar, V; Singh, Rohit
2017-09-01
Acute Otitis Externa (AOE) is also known as swimmer's ear. Investigations initiated during World War II firmly established the role of bacteria in the aetiology of Acute Otitis Externa. To culture the microbiological flora of the normal ear and compare it with the flora causing AOE and to know the role of normal ear canal flora and anaerobes in the aetiology. A prospective observational study was conducted on 64 patients clinically diagnosed with unilateral AOE. Ear swabs were taken from both the ears. Microbiological flora was studied considering diseased ear as test ear and the normal ear as the control. Aerobic and anaerobic cultures were done. Severity of the disease was assessed by subjective and objective scores. Effect of topical treatment with ichthammol glycerine pack was assessed after 48 hours and scores were calculated again. Patients with scores < 4 after pack removal were started on systemic antibiotics and were assessed after seven days of antibiotics course. Data was analysed using Paired t-test, Wilcoxon signed ranks test and Chi-square test. A p-value < 0.05 was considered significant. Pseudomonas aeruginosa (33%) was the most common bacteria cultured from the ear followed by Methicillin Resistant Staphylococcus aureus (MRSA) (18%). Patients with anaerobic organism in the test ear had severe symptoms and needed systemic antibiotic therapy. Most of the cases may respond to empirical antibiotic therapy. In cases with severe symptoms and the ones refractory to empirical treatment, a culture from the ear canal will not be a tax on the patient. This helps in giving a better understanding about the disease, causative organisms and helps in avoiding the use of inappropriate antibiotics that usually result in developing resistant strains of bacteria.
Proposal of a Classification System for the Assessment and Treatment of Prominent Ear Deformity.
Lee, Youngdae; Kim, Young Seok; Lee, Won Jai; Rha, Dong Kyun; Kim, Jiye
2018-06-01
Prominent ear is the most common external ear deformity. To comprehensively treat prominent ear deformity, adequate comprehension of its pathophysiology is crucial. In this article, we analyze cases of prominent ear and suggest a simple classification system and treatment algorithm according to pathophysiology. We retrospectively reviewed a total of 205 Northeast Asian patients' clinical data who underwent an operation for prominent ear deformity. Follow-up assessments were conducted 3, 6, and 12 months after surgery. Prominent ear deformities were classified by diagnostic checkpoints. Class I (simple prominent ear) includes prominent ear that developed with the absence of the antihelix without conchal hypertrophy. Class II (mixed-type prominent ear) is defined as having not only a flat antihelix, but also conchal excess. Class III (conchal-type prominent ear) has an enlarged conchal bowl with a well-developed antihelix. Among the three types of prominent ear, class I was most frequent (162 patients, 81.6%). Class II was observed in 28 patients (13.6%) and class III in 10 patients (4.8%). We used the scaphomastoid suture method for correction of antihelical effacement, the anterior approach conchal resection for correction of conchal hypertrophy, and Bauer's squid incision for lobule prominence. The complication rate was 9.2% including early hematoma, hypersensitivity, and suture extrusion. Unfavorable results occurred in 4% including partial recurrence, overcorrection, and undercorrection. To reduce unfavorable results and avoid recurrence, we propose the use of a classification and treatment algorithm in preoperative evaluation of prominent ear. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Ear Deformations Give Bats a Physical Mechanism for Fast Adaptation of Ultrasonic Beam Patterns
NASA Astrophysics Data System (ADS)
Gao, Li; Balakrishnan, Sreenath; He, Weikai; Yan, Zhen; Müller, Rolf
2011-11-01
A large number of mammals, including humans, have intricate outer ear shapes that diffract incoming sound in a direction- and frequency-specific manner. Through this physical process, the outer ear shapes encode sound-source information into the sensory signals from each ear. Our results show that horseshoe bats could dynamically control these diffraction processes through fast nonrigid ear deformations. The bats’ ear shapes can alter between extreme configurations in about 100 ms and thereby change their acoustic properties in ways that would suit different acoustic sensing tasks.
Boisvert, Isabelle; McMahon, Catherine M.; Dowell, Richard C.; Lyxell, Björn
2015-01-01
In many countries, a single cochlear implant is offered as a treatment for a bilateral hearing loss. In cases where there is asymmetry in the amount of sound deprivation between the ears, there is a dilemma in choosing which ear should be implanted. In many clinics, the choice of ear has been guided by an assumption that the reorganisation of the auditory pathways caused by longer duration of deafness in one ear is associated with poorer implantation outcomes for that ear. This assumption, however, is mainly derived from studies of early childhood deafness. This study compared outcomes following implantation of the better or poorer ear in cases of long-term hearing asymmetries. Audiological records of 146 adults with bilateral hearing loss using a single hearing aid were reviewed. The unaided ear had 15 to 72 years of unaided severe to profound hearing loss before unilateral cochlear implantation. 98 received the implant in their long-term sound-deprived ear. A multiple regression analysis was conducted to assess the relative contribution of potential predictors to speech recognition performance after implantation. Duration of bilateral significant hearing loss and the presence of a prelingual hearing loss explained the majority of variance in speech recognition performance following cochlear implantation. For participants with postlingual hearing loss, similar outcomes were obtained by implanting either ear. With prelingual hearing loss, poorer outcomes were obtained when implanting the long-term sound-deprived ear, but the duration of the sound deprivation in the implanted ear did not reliably predict outcomes. Contrary to an apparent clinical consensus, duration of sound deprivation in one ear has limited value in predicting speech recognition outcomes of cochlear implantation in that ear. Outcomes of cochlear implantation are more closely related to the period of time for which the brain is deprived of auditory stimulation from both ears. PMID:26043227
Correlation between the characteristics of resonance and aging of the external ear.
Silva, Aline Papin Roedas da; Blasca, Wanderléia Quinhoneiro; Lauris, José Roberto Pereira; Oliveira, Jerusa Roberta Massola de
2014-01-01
Aging causes changes in the external ear as a collapse of the external auditory canal and tympanic membrane senile. Knowing them is appropriate for the diagnosis of hearing loss and selection of hearing aids. For this reason, the study aimed to verify the influence of the anatomical changes of the external ear resonance in the auditory canal in the elderly. The sample consisted of objective measures of the external ear of elderly with collapse (group A), senile tympanic membrane (group B) and without changing the external auditory canal or tympanic membrane (group C) and adults without changing the external ear (group D). In the retrospective/clinical study were performed comparisons of measures of individuals with and without alteration of the external ear through the gain and response external ear resonant frequency and the primary peak to the right ear. In groups A, B and C was no statistically significant difference between Real Ear Unaided Response (REUR) and Real Ear Unaided Gain (REUG), but not for the peak frequency. For groups A and B were shown significant differences in REUR and REUG. Between the C and D groups were significant statistics to the REUR and REUG, but not for the frequency of the primary peak. Changes influence the external ear resonance, decreasing its amplitude. However, the frequency of the primary peak is not affected.
Middle Ear Infection (Chronic Otitis Media) and Hearing Loss
... You Middle Ear Infection (Chronic Otitis Media) and Hearing Loss Middle Ear Infection (Chronic Otitis Media) and ... loss. How does otitis media affect a childs hearing? All children with middle ear infection or fluid ...
Testing a Method for Quantifying the Output of Implantable Middle Ear Hearing Devices
Rosowski, J.J.; Chien, W.; Ravicz, M.E.; Merchant, S.N.
2008-01-01
This report describes tests of a standard practice for quantifying the performance of implantable middle ear hearing devices (also known as implantable hearing aids). The standard and these tests were initiated by the Food and Drug Administration of the United States Government. The tests involved measurements on two hearing devices, one commercially available and the other home built, that were implanted into ears removed from human cadavers. The tests were conducted to investigate the utility of the practice and its outcome measures: the equivalent ear canal sound pressure transfer function that relates electrically driven middle ear velocities to the equivalent sound pressure needed to produce those velocities, and the maximum effective ear canal sound pressure. The practice calls for measurements in cadaveric ears in order to account for the varied anatomy and function of different human middle ears. PMID:17406105
Reconstruction of partially amputated external ear with costal cartilage graft: case report.
Brunelli, A; Bottini, D J; Cervelli, V; Cervelli, G; Grimaldi, M
2004-06-01
Many causes are responsible for secondary anomalies of the outer ear, such as: car accidents, sport- or work-related accidents, assaults, bites from animals or humans, benign or malignant tumours, burns and the effects of surgical interventions of the ear (plastic surgery on the ear or attempts at correction of primary malformations of the ear). The anatomical complexity of the ear makes its reconstruction particularly complicated with post-operative results that are often disappointing. The Authors describe their experience in the reconstruction of a partially amputated outer ear following a dog bite. The therapeutic protocol required various surgical stages. Initially, a cutaneous expander was applied at the level of the mastoid in order to ensure a sufficient quantity of local skin. The second stage was to remove cartilage from the ribs, followed by construction of a cartilaginous model of the ear and its insertion into the subcutaneous mastoid region after removal of the cutaneous expander and any residual ear cartilage. The last stage was to separate the neo-formed outer ear from the mastoid skin with the insertion of a cartilage graft to the posterior region of the reconstructed ear. This graft was covered by the occipital fascia rotated at 180 degrees and by a skin graft removed from the pubis. The postoperative result was satisfactory with recuperation of a good aesthetic appearance of the ear. Aim of the present report is to describe the surgical technique employed in the reconstruction of secondary anomalies of the ear and to highlight errors committed during this procedure. These considerations have allowed us to stress some fundamental elements in the reconstruction of the ear. In particular, the watershed was the awareness that we had to create a cartilaginous model that respected, as far as possible, the anatomy of the outer ear with all its ridges, trenches and cavities. This as well as ensuring a sufficient quantity of local skin in order to cover the cartilaginous graft and, therefore, reduce the risk of exposing the cartilage and subsequent infection, to guarantee an optimal end result.
Ma, Ning; Morris, Saffron; Kitterick, Pádraig Thomas
2016-01-01
Objectives: This study used vocoder simulations with normal-hearing (NH) listeners to (1) measure their ability to integrate speech information from an NH ear and a simulated cochlear implant (CI), and (2) investigate whether binaural integration is disrupted by a mismatch in the delivery of spectral information between the ears arising from a misalignment in the mapping of frequency to place. Design: Eight NH volunteers participated in the study and listened to sentences embedded in background noise via headphones. Stimuli presented to the left ear were unprocessed. Stimuli presented to the right ear (referred to as the CI-simulation ear) were processed using an eight-channel noise vocoder with one of the three processing strategies. An Ideal strategy simulated a frequency-to-place map across all channels that matched the delivery of spectral information between the ears. A Realistic strategy created a misalignment in the mapping of frequency to place in the CI-simulation ear where the size of the mismatch between the ears varied across channels. Finally, a Shifted strategy imposed a similar degree of misalignment in all channels, resulting in consistent mismatch between the ears across frequency. The ability to report key words in sentences was assessed under monaural and binaural listening conditions and at signal to noise ratios (SNRs) established by estimating speech-reception thresholds in each ear alone. The SNRs ensured that the monaural performance of the left ear never exceeded that of the CI-simulation ear. The advantages of binaural integration were calculated by comparing binaural performance with monaural performance using the CI-simulation ear alone. Thus, these advantages reflected the additional use of the experimentally constrained left ear and were not attributable to better-ear listening. Results: Binaural performance was as accurate as, or more accurate than, monaural performance with the CI-simulation ear alone. When both ears supported a similar level of monaural performance (50%), binaural integration advantages were found regardless of whether a mismatch was simulated or not. When the CI-simulation ear supported a superior level of monaural performance (71%), evidence of binaural integration was absent when a mismatch was simulated using both the Realistic and the Ideal processing strategies. This absence of integration could not be accounted for by ceiling effects or by changes in SNR. Conclusions: If generalizable to unilaterally deaf CI users, the results of the current simulation study would suggest that benefits to speech perception in noise can be obtained by integrating information from an implanted ear and an NH ear. A mismatch in the delivery of spectral information between the ears due to a misalignment in the mapping of frequency to place may disrupt binaural integration in situations where both ears cannot support a similar level of monaural speech understanding. Previous studies that have measured the speech perception of unilaterally deaf individuals after CI but with nonindividualized frequency-to-electrode allocations may therefore have underestimated the potential benefits of providing binaural hearing. However, it remains unclear whether the size and nature of the potential incremental benefits from individualized allocations are sufficient to justify the time and resources required to derive them based on cochlear imaging or pitch-matching tasks. PMID:27116049
Ma, Ning; Morris, Saffron; Kitterick, Pádraig Thomas
2016-01-01
This study used vocoder simulations with normal-hearing (NH) listeners to (1) measure their ability to integrate speech information from an NH ear and a simulated cochlear implant (CI), and (2) investigate whether binaural integration is disrupted by a mismatch in the delivery of spectral information between the ears arising from a misalignment in the mapping of frequency to place. Eight NH volunteers participated in the study and listened to sentences embedded in background noise via headphones. Stimuli presented to the left ear were unprocessed. Stimuli presented to the right ear (referred to as the CI-simulation ear) were processed using an eight-channel noise vocoder with one of the three processing strategies. An Ideal strategy simulated a frequency-to-place map across all channels that matched the delivery of spectral information between the ears. A Realistic strategy created a misalignment in the mapping of frequency to place in the CI-simulation ear where the size of the mismatch between the ears varied across channels. Finally, a Shifted strategy imposed a similar degree of misalignment in all channels, resulting in consistent mismatch between the ears across frequency. The ability to report key words in sentences was assessed under monaural and binaural listening conditions and at signal to noise ratios (SNRs) established by estimating speech-reception thresholds in each ear alone. The SNRs ensured that the monaural performance of the left ear never exceeded that of the CI-simulation ear. The advantages of binaural integration were calculated by comparing binaural performance with monaural performance using the CI-simulation ear alone. Thus, these advantages reflected the additional use of the experimentally constrained left ear and were not attributable to better-ear listening. Binaural performance was as accurate as, or more accurate than, monaural performance with the CI-simulation ear alone. When both ears supported a similar level of monaural performance (50%), binaural integration advantages were found regardless of whether a mismatch was simulated or not. When the CI-simulation ear supported a superior level of monaural performance (71%), evidence of binaural integration was absent when a mismatch was simulated using both the Realistic and the Ideal processing strategies. This absence of integration could not be accounted for by ceiling effects or by changes in SNR. If generalizable to unilaterally deaf CI users, the results of the current simulation study would suggest that benefits to speech perception in noise can be obtained by integrating information from an implanted ear and an NH ear. A mismatch in the delivery of spectral information between the ears due to a misalignment in the mapping of frequency to place may disrupt binaural integration in situations where both ears cannot support a similar level of monaural speech understanding. Previous studies that have measured the speech perception of unilaterally deaf individuals after CI but with nonindividualized frequency-to-electrode allocations may therefore have underestimated the potential benefits of providing binaural hearing. However, it remains unclear whether the size and nature of the potential incremental benefits from individualized allocations are sufficient to justify the time and resources required to derive them based on cochlear imaging or pitch-matching tasks.
Cauliflower Ear and Skin Infections among Wrestlers in Tehran.
Kordi, Ramin; Mansournia, Mohammad Ali; Nourian, Roh Allah; Wallace, W Angus
2007-01-01
The purpose of the study was to describe the magnitude of the selected sports medicine problems (i.e. cauliflower ear and skin infections) among wrestlers in Tehran. A number of 411 wrestlers were randomly selected from wrestling clubs in Tehran employing cluster sample setting method. The participants were interviewed using a specially designed and validated questionnaire. Nearly half of the participants (44%) had "cauliflower ears". Only 23% of these participants had received any kind of treatment for their acute ear haematomas that are known to result in "cauliflower ears". The prevalence of reported hearing loss among participants with cauliflower ears (11.5%, 95%CI: 6.9 to 16.2) was significantly more than this prevalence among those participants without cauliflower ears (1.8%, 95%CI: 0.1 to 3.5) (p < 0.05). More than half of the participants (52%) had skin infection diagnosed by a physician during the previous year. This study has identified evidence of an increase in hearing loss as a possible side effect of either cauliflower ear or ear injury in wrestling in Iran. There has been an outbreak of ringworm and there is a significant potential for an outbreak of impetigo among wrestlers in Tehran. Key pointsSkin infections are prevalent among wrestlers in Tehran.Commonly wrestlers in Tehran continue to carry out wrestling training while affected by skin infections.Cauliflower ear "is common among wrestlers in Tehran.More research is needed to investigate hearing loss as a possible side effect of either cauliflower ear or ear injury in wrestling in Iran.
Middle ear osteoma causing progressive facial nerve weakness: a case report.
Curtis, Kate; Bance, Manohar; Carter, Michael; Hong, Paul
2014-09-18
Facial nerve weakness is most commonly due to Bell's palsy or cerebrovascular accidents. Rarely, middle ear tumor presents with facial nerve dysfunction. We report a very unusual case of middle ear osteoma in a 49-year-old Caucasian woman causing progressive facial nerve deficit. A subtle middle ear lesion was observed on otoscopy and computed tomographic images demonstrated an osseous middle ear tumor. Complete surgical excision resulted in the partial recovery of facial nerve function. Facial nerve dysfunction is rarely caused by middle ear tumors. The weakness is typically due to a compressive effect on the middle ear portion of the facial nerve. Early recognition is crucial since removal of these lesions may lead to the recuperation of facial nerve function.
... may have OTITIS MEDIA, an infection of the middle ear. Self CareSee your doctor. Many ear infections will ... half-alcohol, half-white vinegar solution in the ear before and after swimming or ... JOINT (TMJ) SYNDROME, a disorder that affects the jaw joint, may ...
McIntire, Sean; Boujie, Lee
2016-01-01
Inner ear barotrauma can occur when the gas-filled chambers of the ear have difficulty equalizing pressure with the outside environment after changes in ambient pressure. This can transpire even with small pressure changes. Hypobaric or hyperbaric environments can place significant stress on the structures of the middle and inner ear. If methods to equalize pressure between the middle ear and other connected gas-filled spaces (i.e., Valsalva maneuver) are unsuccessful, middle ear overpressurization can occur. This force can be transmitted to the fluid-filled inner ear, making it susceptible to injury. Damage specifically to the structures of the vestibulocochlear system can lead to symptoms of vertigo, hearing loss, and tinnitus. This article discusses the case of a 23-year-old male Marine who presented with symptoms of nausea and gait instability after performing underwater pool competency exercises to a maximum depth of 13 feet, without breathing compressed air. Diagnosis and management of inner ear barotrauma are reviewed, as is differentiation from inner ear decompression sickness. 2016.
Chowdhury, Debbrota Paul; Bakshi, Sambit; Guo, Guodong; Sa, Pankaj Kumar
2017-11-27
In this paper, an overall framework has been presented for person verification using ear biometric which uses tunable filter bank as local feature extractor. The tunable filter bank, based on a half-band polynomial of 14th order, extracts distinct features from ear images maintaining its frequency selectivity property. To advocate the applicability of tunable filter bank on ear biometrics, recognition test has been performed on available constrained databases like AMI, WPUT, IITD and unconstrained database like UERC. Experiments have been conducted applying tunable filter based feature extractor on subparts of the ear. Empirical experiments have been conducted with four and six subdivisions of the ear image. Analyzing the experimental results, it has been found that tunable filter moderately succeeds to distinguish ear features at par with the state-of-the-art features used for ear recognition. Accuracies of 70.58%, 67.01%, 81.98%, and 57.75% have been achieved on AMI, WPUT, IITD, and UERC databases through considering Canberra Distance as underlying measure of separation. The performances indicate that tunable filter is a candidate for recognizing human from ear images.
Is Attention Shared Between the Ears?1
Shiffrin, Richard M.; Pisoni, David B.; Castaneda-Mendez, Kicab
2012-01-01
This study tests the locus of attention during selective listening for speech-like stimuli. Can processing be differentially allocated to the two ears? Two conditions were used. The simultaneous condition involved one of four randomly chosen stop-consonants being presented to one of the ears chosen at random. The sequential condition involved two intervals; in the first S listened to the right ear; in the second S listened to the left ear. One of the four consonants was presented to an attended ear during one of these intervals. Experiment I used no distracting stimuli. Experiment II utilized a distracting consonant not confusable with any of the four target consonants. This distractor was always presented to any ear not containing a target. In both experiments, simultaneous and sequential performance were essentially identical, despite the need for attention sharing between the two ears during the simultaneous condition. We conclude that selective attention does not occur during perceptual processing of speech sounds presented to the two ears. We suggest that attentive effects arise in short-term memory following processing. PMID:23226838
Active middle ear implant after lateral petrosectomy and radiotherapy for ear cancer.
Cristalli, Giovanni; Sprinzl, Georg M; Wolf-Magele, Astrid; Marchesi, Paolo; Mercante, Giuseppe; Spriano, Giuseppe
2014-04-01
Tumor of the temporal bone is a rare disease with a very poor prognosis. Surgery and postoperative radiotherapy are usually the recommended treatments for squamous cell carcinoma (SCC) of the external and middle ear, which may cause conductive hearing loss. The purpose of this study was to evaluate the audiologic results and compliance of active middle ear implant (AMEI) and establish the feasibility of the procedure in a patient treated for middle ear cancer. A 73-year-old patient treated with lateral petrosectomy, neck dissection, reconstruction/obliteration by pedicled pectoralis major myocutaneous flap, and postoperative full dose radiotherapy for external and middle ear SCC was selected for AMEI. Preoperative audiometric and speech audiometry tests were performed on both ears before and after the activation. Pure tone free field audiometry. Binaural free field speech audiogram. Aided pure tone free field audiometry AMEI results show an increase in air conduction. Speech audiogram showed better discrimination scores in AMEI-aided situations. No complications were observed. AMEI after surgery followed by radiotherapy for middle ear cancer is feasible. Acoustic results in obliterated ear are satisfactory.
Klippel-Feil syndrome and associated ear anomalies.
Yildirim, Nadir; Arslanoğlu, Atilla; Mahiroğullari, Mahir; Sahan, Murat; Ozkan, Hüseyin
2008-01-01
Klippel-Feil syndrome (KFS) is a congenital segmentation anomaly of the cervical vertebrae that manifests as short neck, low hair line, and limited neck mobility. Various systemic malformations may also accompany the syndrome including wide variety of otopathologies affecting all 3 compartments of the ear (external, middle, and inner ear) as well as internal acoustic canal and vestibular aqueduct. We aimed to investigate these involvements and their clinical correlates in a group of patients with KFS. We present 20 KFS cases, of which 12 (% 60) displayed most of the reported ear abnormalities such as microtia, external ear canal stenosis, chronic ear inflammations and their sequels, anomalies of the tympanic cavity and ossicles, inner ear dysplasies, deformed internal acoustic canal, and wide vestibular aqueduct, which are demonstrated using the methods of otoscopy, audiologic testing, and temporal bone computed tomography. This series represents one of the highest reported rate of ear involvement in KFS. We found no correlation between the identified ear pathologies and the skeletal and extraskeletal malformations. The genetic nature of the syndrome was supported by the existence of affected family members in 4 (20%) of the cases.
Major evolutionary transitions and innovations: the tympanic middle ear
2017-01-01
One of the most amazing transitions and innovations during the evolution of mammals was the formation of a novel jaw joint and the incorporation of the original jaw joint into the middle ear to create the unique mammalian three bone/ossicle ear. In this review, we look at the key steps that led to this change and other unusual features of the middle ear and how developmental biology has been providing an understanding of the mechanisms involved. This starts with an overview of the tympanic (air-filled) middle ear, and how the ear drum (tympanic membrane) and the cavity itself form during development in amniotes. This is followed by an investigation of how the ear is connected to the pharynx and the relationship of the ear to the bony bulla in which it sits. Finally, the novel mammalian jaw joint and versatile dentary bone will be discussed with respect to evolution of the mammalian middle ear. This article is part of the themed issue ‘Evo-devo in the genomics era, and the origins of morphological diversity’. PMID:27994124
Practical otic anatomy and physiology of the dog and cat.
Njaa, Bradley L; Cole, Lynette K; Tabacca, Natalie
2012-11-01
Knowledge of the normal structure and function of the canine and feline ear is critical to be able to diagnose abnormalities that either involve the ear or originate within one or more of the ear compartments. In addition, a veterinarian must be aware of various structures within or associated with the ear so that they are not damaged or destroyed while treating an animal with otic disease. This article provides a brief discussion of the various anatomic features of the ear and normal physiology of portions of the ear. Copyright © 2012 Elsevier Inc. All rights reserved.
Management of auricular hematoma and the cauliflower ear.
Greywoode, Jewel D; Pribitkin, Edmund A; Krein, Howard
2010-12-01
Acute auricular hematoma is common after blunt trauma to the side of the head. A network of vessels provides a rich blood supply to the ear, and the ear cartilage receives its nutrients from the overlying perichondrium. Prompt management of hematoma includes drainage and prevention of reaccumulation. If left untreated, an auricular hematoma can result in complications such as perichondritis, infection, and necrosis. Cauliflower ear may result from long-standing loss of blood supply to the ear cartilage and formation of neocartilage from disrupted perichondrium. Management of cauliflower ear involves excision of deformed cartilage and reshaping of the auricle. © Thieme Medical Publishers.
[Advances in genetics of congenital malformation of external and middle ear].
Wang, Dayong; Wang, Qiuju
2013-05-01
Congenital malformation of external and middle ear is a common disease in ENT department, and the incidence of this disease is second only to cleft lip and palate in the whole congenital malformations of the head and face. The external and middle ear malformations may occur separately, or as an important ear symptom of the systemic syndrome. We systematically review and analysis the genetic research progress of congenital malformation of external and middle ear, which would be helpful to understand the mechanism of external and middle ear development, and to provide clues for the further discovery of new virulence genes.
Contralateral ear occlusion for improving the reliability of otoacoustic emission screening tests.
Papsin, Emily; Harrison, Adrienne L; Carraro, Mattia; Harrison, Robert V
2014-01-01
Newborn hearing screening is an established healthcare standard in many countries and testing is feasible using otoacoustic emission (OAE) recording. It is well documented that OAEs can be suppressed by acoustic stimulation of the ear contralateral to the test ear. In clinical otoacoustic emission testing carried out in a sound attenuating booth, ambient noise levels are low such that the efferent system is not activated. However in newborn hearing screening, OAEs are often recorded in hospital or clinic environments, where ambient noise levels can be 60-70 dB SPL. Thus, results in the test ear can be influenced by ambient noise stimulating the opposite ear. Surprisingly, in hearing screening protocols there are no recommendations for avoiding contralateral suppression, that is, protecting the opposite ear from noise by blocking the ear canal. In the present study we have compared transient evoked and distortion product OAEs measured with and without contralateral ear plugging, in environmental settings with ambient noise levels <25 dB SPL, 45 dB SPL, and 55 dB SPL. We found out that without contralateral ear occlusion, ambient noise levels above 55 dB SPL can significantly attenuate OAE signals. We strongly suggest contralateral ear occlusion in OAE based hearing screening in noisy environments.
An, Dong; Cui, Yongjin; Liu, Xu; Jia, Shiqiang; Zheng, Shuyun; Che, Xiaoping; Liu, Zhe; Zhang, Xiaodong; Zhu, Dehai; Li, Shaoming
2016-01-01
The effects of varieties, producing areas, ears, and ear positions of maize on near-infrared (NIR) spectra were investigated to determine the factors causing the differences in NIR fingerprints of maize varieties. A total of 130 inbred lines were grown in two regions in China, and 12,350 kernel samples were analyzed through NIR spectroscopy. Spectral differences among varieties, producing areas, ears, and ear positions were determined and compared on the basis of pretreated spectra. The bands at 1300-1470, 1768-1949, 2010-2064, and 2235-2311 nm were mainly affected by the producing area. Band selection and principal component analysis were applied to improve the influence of variety on NIR spectra by processing the pretreated spectra. The degrees of the influence of varieties, producing areas, ears, and ear positions were calculated, and the percentages of the influence of varieties, producing areas, ears, and ear positions were 45.40%, 42.66%, 8.22%, and 3.72%, respectively. Therefore, genetic differences among maize inbred lines are the main factors accounted for NIR spectral differences. Producing area is a secondary factor. These results could provide a reference for researchers who authenticate varieties, perform geographical origin traceabilities, and conduct maize seed breeding.
A short-wave infrared otoscope for middle ear disease diagnostics (Conference Presentation)
NASA Astrophysics Data System (ADS)
Carr, Jessica A.; Valdez, Tulio; Bruns, Oliver; Bawendi, Moungi
2016-02-01
Otitis media, a range of inflammatory conditions of the middle ear, is the second most common illness diagnosed in children. However, the diagnosis can be challenging, particularly in pediatric patients. Otitis media is commonly over-diagnosed and over-treated and has been identified as one of the primary factors in increased antibiotic resistance. We describe the development of a short-wave infrared (SWIR) otoscope for objective middle ear effusion diagnosis. The SWIR otoscope can unambiguously detect the presence of middle ear fluid based on its strong light absorption in the SWIR. This absorption causes a stark, visual contrast between the presence and absence of fluid behind the tympanic membrane. Additionally, when there is no middle ear fluid, the deeper tissue penetration of SWIR light allows the SWIR otoscope to better visualize middle ear anatomy through the tympanic membrane than is possible with visible light. We demonstrate that in healthy, adult human ears, SWIR otoscopy can image a range of middle ear anatomy, including landmarks of the entire ossicular chain, the promontory, the round window niche, and the chorda tympani. We suggest that SWIR otoscopy can provide valuable diagnostic information complementary to that provided by visible pneumotoscopy in the diagnosis of middle ear effusions, otitis media, and other maladies of the middle ear.
Fly-ear inspired acoustic sensors for gunshot localization
NASA Astrophysics Data System (ADS)
Liu, Haijun; Currano, Luke; Gee, Danny; Yang, Benjamin; Yu, Miao
2009-05-01
The supersensitive ears of the parasitoid fly Ormia ochracea have inspired researchers to develop bio-inspired directional microphone for sound localization. Although the fly ear is optimized for localizing the narrow-band calling song of crickets at 5 kHz, experiments and simulation have shown that it can amplify directional cues for a wide frequency range. In this article, a theoretical investigation is presented to study the use of fly-ear inspired directional microphones for gunshot localization. Using an equivalent 2-DOF model of the fly ear, the time responses of the fly ear structure to a typical shock wave are obtained and the associated time delay is estimated by using cross-correlation. Both near-field and far-field scenarios are considered. The simulation shows that the fly ear can greatly amplify the time delay by ~20 times, which indicates that with an interaural distance of only 1.2 mm the fly ear is able to generate a time delay comparable to that obtained by a conventional microphone pair with a separation as large as 24 mm. Since the parameters of the fly ear structure can also be tuned for muzzle blast and other impulse stimulus, fly-ear inspired acoustic sensors offers great potential for developing portable gunshot localization systems.
Desmoplastic small round cell tumor of the middle ear: A case report.
Xu, Jing; Yao, Mengwei; Yang, Xinxin; Liu, Tao; Wang, Shaohua; Ma, Dengdian; Li, Xiaoyu
2018-04-01
Desmoplastic small round cell tumor (DSRCT) is a rare, aggressive and malignant tumor. This report describes a case involving DSRCT of the middle ear which no case has been reported in the literature till date. A 59-year-old Chinese man with a 40-year history of repeated suppuration of his right ear and 1-year history of drooping of the angle of mouth. The CT of the middle ear and brain scan and enhanced MRI showed space occupying lesion in the right middle ear. Desmoplastic small round cell tumor of the middle ear. After relevant examinations, radical mastoidectomy and subtotal temporal bone resection were performed on the right ear under general anesthesia. The patient underwent postoperative adjuvant chemoradiation therapy. The patient was counterchecked regularly,there was norecurrence of DSRCT of the middle ear. Four years after surgery, the CT and MRI of the middle ear mastoid showed right middle ear soft tissue shadow,but postoperative pathological results showed proliferative fibrous and vascular tissues with chronic inflammatory cell infiltration and necrosis. DSRCT is a relatively aggressive, malignant mesenchymal tumor, with a very poor prognosis.The diagnosis of DSRCT relies on immunohistological data. Early diagnosis, radical surgery, chemotherapy, and radiotherapy are considered a reasonable way to prolong survival.
Reeder, Ruth M; Firszt, Jill B; Cadieux, Jamie H; Strube, Michael J
2017-01-01
Whether, and if so when, a second-ear cochlear implant should be provided to older, unilaterally implanted children is an ongoing clinical question. This study evaluated rate of speech recognition progress for the second implanted ear and with bilateral cochlear implants in older sequentially implanted children and evaluated localization abilities. A prospective longitudinal study included 24 bilaterally implanted children (mean ear surgeries at 5.11 and 14.25 years). Test intervals were every 3-6 months through 24 months postbilateral. Test conditions were each ear and bilaterally for speech recognition and localization. Overall, the rate of progress for the second implanted ear was gradual. Improvements in quiet continued through the second year of bilateral use. Improvements in noise were more modest and leveled off during the second year. On all measures, results from the second ear were poorer than the first. Bilateral scores were better than either ear alone for all measures except sentences in quiet and localization. Older sequentially implanted children with several years between surgeries may obtain speech understanding in the second implanted ear; however, performance may be limited and rate of progress gradual. Continued contralateral ear hearing aid use and reduced time between surgeries may enhance outcomes.
2008-01-01
Introduction Ear wax only becomes a problem if it causes a hearing impairment or other ear-related symptoms. Ear wax is more likely to accumulate and cause a hearing impairment when normal extrusion is prevented — for example, by the use of hearing aids, or by the use of cotton buds to clean the ears. Ear wax can visually obscure the ear drum, and may need to be removed for diagnostic purposes. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical question: What are the effects of methods to remove ear wax? We searched: Medline, Embase, The Cochrane Library, and other important databases up to June 2007 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found nine systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review, we present information relating to the effectiveness and safety of the following interventions: ear syringing; manual removal (other than ear syringing); and wax softeners (alone or prior to syringing). PMID:19450340
Effect of cochlear implantation on middle ear function: A three-month prospective study.
Wasson, Joseph D; Campbell, Luke; Chambers, Scott; Hampson, Amy; Briggs, Robert J S; O'Leary, Stephen J
2018-05-01
To determine if cochlear implantation has a delayed effect on the middle ear conductive hearing mechanism by measuring laser Doppler vibrometry (LDV) of the tympanic membrane (TM) in both implanted and contralateral control ears preoperatively and 3 months postoperatively, and then comparing the relative change in LDV outcome measures between implanted and control ears. Prospective cohort study. Eleven preoperative adult unilateral cochlear implant recipients in previously unoperated ears with normal anatomy and aerated temporal bones were included in this study. The magnitude and phase angle of umbo velocity transfer function in response to air- conduction (AC) stimulus, and the magnitude of umbo velocity in response to bone- conduction (BC) stimulus were measured in the implant ear and the contralateral control ear preoperatively and 3 months postoperatively and compared. No significant changes in the magnitude or phase angle of TM velocity in response to either AC or BC stimulus were observed in the implanted ear relative to the contralateral control ear 3 months following cochlear implantation. From the results of LDV measurements, it can be said that cochlear implantation has no significant delayed effect on the middle ear conductive mechanism. 4. Laryngoscope, 128:1207-1212, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Womack, Molly C; Christensen-Dalsgaard, Jakob; Hoke, Kim L
2016-10-15
Most vertebrates have evolved a tympanic middle ear that enables effective hearing of airborne sound on land. Although inner ears develop during the tadpole stages of toads, tympanic middle ear structures are not complete until months after metamorphosis, potentially limiting the sensitivity of post-metamorphic juveniles to sounds in their environment. We tested the hearing of five species of toads to determine how delayed ear development impairs airborne auditory sensitivity. We performed auditory brainstem recordings to test the hearing of the toads and used micro-computed tomography and histology to relate the development of ear structures to hearing ability. We found a large (14-27 dB) increase in hearing sensitivity from 900 to 2500 Hz over the course of ear development. Thickening of the tympanic annulus cartilage and full ossification of the middle ear bone are associated with increased hearing ability in the final stages of ear maturation. Thus, juvenile toads are at a hearing disadvantage, at least in the high-frequency range, throughout much of their development, because late-forming ear elements are critical to middle ear function at these frequencies. We discuss the potential fitness consequences of late hearing development, although research directly addressing selective pressures on hearing sensitivity across ontogeny is lacking. Given that most vertebrate sensory systems function very early in life, toad tympanic hearing may be a sensory development anomaly. © 2016. Published by The Company of Biologists Ltd.
Sun, Xiao-wei; Zhang, Jian-ji; Ding, Yuan-ping; Dou, Fen-fen; Zhang, Han-bing; Gong, Ke-bo; Xu, An-ting
2011-05-01
To evalute the efficacy of high-resolution CT(HRCT) in differential diagnosis and treatment of chronic suppurative otitis media and cholesteatoma otitis media by soft-tissue shadows. HRCT scanning was performed in 120 cases, 153 ears, with chronic otitis suppurative media and cholesteatoma otitis media, of which original data were processed with multi-planar reconstruction (MPR) and maximum intensity projection (MIP), the characteristics of the soft-tissue shadows' growth, window width or window leveling and bony destruction were respectively observed, as well as compared with the surgery findings. In 120 patients (153 ears), 109 ears were diagnosed as cholesteatoma otitis media, and 44 ears were diagnosed as chronic suppurative otitis media, among which 33 ears had granulation tissue and 11 ears had secretion. One hundred and seven ears were postoperatively diagnosed as cholesteatoma otitis media, among which 25 ears had granulation tissue. Among 46 ears of chronic suppurative otitis media, 35 ears had granulation tissue, and only 11 ears had secretion. A 98.6% diagnostic accuracy can be reached with HRCT in diagnosing cholesteatoma otitis media and chronic suppurative otitis media. The Youden's index was 0.98, 0.98 and 1.00 respectively with HRCT in diagnosing cholesteatoma, granulation tissue and secretion. Combination of the three different imaging methods, axial images, coronal MPR images and MIP images, can improve the efficacy of the HRCT diagnosis and definite chronic otitis media, which can be routinely used for surgery plan.
Ear Infection in Isolated Cleft Lip: Etiological Implications.
Ruegg, Teresa A; Cooper, Margaret E; Leslie, Elizabeth J; Ford, Matthew D; Wehby, George L; Deleyiannis, Frederic W B; Czeizel, Andrew E; Hecht, Jacqueline T; Marazita, Mary L; Weinberg, Seth M
2017-03-01
Chronic ear infections are a common occurrence in children with orofacial clefts involving the secondary palate. Less is known about the middle ear status of individuals with isolated clefts of the lip, although several studies have reported elevated rates of ear infection in this group. The purpose of this retrospective study was to test the hypothesis that chronic ear infections occur more frequently in isolated cleft lip cases (n = 94) compared with controls (n = 183). A questionnaire was used to obtain information on history of chronic ear infection. The association between ear infection status (present/absent) and cleft lip status (cleft lip case/control) was tested using both chi-square and logistic regression. The reported occurrence of chronic ear infection was significantly greater in cleft lip cases (31%) compared with unaffected controls (11%). After adjusting for age and sex, having a cleft lip increased the odds of being positive for ear infection by a factor greater than 3 (odds ratio = 3.698; 95% confidence interval = 1.91 to 7.14). Within cleft lip cases, there was no difference in the occurrence of ear infection by defect laterality or by the type of clefting present in the family history. Although velopharyngeal insufficiency was present in 18.4% of our cleft lip sample, there was no statistical association between ear infection and abnormal speech patterns. These results may have potential implications both for the clinical management of isolated cleft lip cases and for understanding the etiology of orofacial clefting.
Inner ear problems of Thai priest at Priest Hospital.
Karnchanakas, Taweporn; Tantanavat, Are; Sinsakontavat, Jamjan
2008-01-01
The inner ear problems of Thai priest at Priest Hospital had never been reported previously, so Department of Ear Nose Throat try to correlate the metebotic disorder with inner ear problems. 1) To study the fasting blood sugar (FBS), total cholesterol (T. Chol), low density lipoprotein (LDL), and triglyceride (TG), the factors expected to involve in inner ear problems of priests at Priest Hospital. 2) To compare the FBS, T. Chol, HDL, LDL, and TG of priests with inner ear problems at Priest Hospital. 3) To find the percentage of abnormal from FBS, T. Chol, LDL, and TG. The study using 83 sampling of priests with inner ear problems and 107 priests as a controlled group. The research instruments used to collect data was the questionnaire which composed of general information, physical, ear-nose-throat and neurological examination, pure tone audiometry, brainstem evoke response audiometry (BERA) and the blood tests:FBS, T. Chol, TG, and LDL. The inner ear problems were composed of: 1) Dizziness 2) Hearing Loss 3) Tinnitus Aurium. The descriptive statistics were used to analyze the data from questionnaires and utilized frequency, percentage, standard deviation (S.D.) and t-test to achieve desired results. Priest at middle age and elderly with inner ear problems had greater FBS and TG than expected values of the control group. The middle age and elderly priests who had greater FBS and TG than expected values were sick with inner ear problems that causing dizziness, hearing loss and tinnitus aurium.
Ear Infection in Isolated Cleft Lip: Etiological Implications
Ruegg, Teresa A.; Cooper, Margaret E.; Leslie, Elizabeth J.; Ford, Matthew D.; Wehby, George L.; Deleyiannis, Frederic W.B.; Czeizel, Andrew E.; Hecht, Jacqueline T.; Marazita, Mary L.; Weinberg, Seth M.
2015-01-01
Background and Hypothesis Chronic ear infections are a common occurrence in children with orofacial clefts involving the secondary palate. Less is known about the middle ear status of individuals with isolated clefts of the lip, although several studies have reported elevated rates of ear infection in this group. The purpose of this retrospective study was to test the hypothesis that chronic ear infections occur more frequently in isolated cleft lip cases (n=94) compared with controls (n=183). Methods A questionnaire was used to obtain information on history of chronic ear infection. The association between ear infection status (present/absent) and cleft lip status (cleft lip case/control) was tested using both chi-square and logistic regression. Results and Conclusions The reported occurrence of chronic ear infection was significantly greater in cleft lipcases (31%) compared to unaffected controls (11%). After adjusting for age and sex, having a cleft lip increased the odds of being positive for ear infection by a factor greater than three (OR=3.698; 95%CI=1.91–7.14). Within cleft lipcases, there was no difference in the occurrence of ear infection by defect laterality or by the type of clefting present in the family history. Although velopharyngeal insufficiency was present in 18.4% of our cleft lip sample, there was no statistical association between ear infection and abnormal speech patterns. These results may have potential implications both for the clinical management of isolated cleft lip cases and for understanding the etiology of orofacial clefting. PMID:26153759
Akiyama, Naotaro; Yamamoto-Fukuda, Tomomi; Takahashi, Haruo; Koji, Takehiko
2013-01-01
Middle-ear mucosa maintains middle-ear pressure. However, the majority of surgical cases exhibit inadequate middle-ear mucosal regeneration, and mucosal transplantation is necessary in such cases. The aim of the present study was to assess the feasibility of transplantation of isolated mucosal cells encapsulated within synthetic self-assembling peptide nanofiber scaffolds using PuraMatrix, which has been successfully used as scaffolding in tissue engineering, for the repair of damaged middle-ear. Middle-ear bullae with mucosa were removed from Sprague Dawley (SD) transgenic rats, transfected with enhanced green fluorescent protein (EGFP) transgene and excised into small pieces, then cultured up to the third passage. After surgical elimination of middle-ear mucosa in SD recipient rats, donor cells were encapsulated within PuraMatrix and transplanted into these immunosuppressed rats. Primary cultured cells were positive for pancytokeratin but not for vimentin, and retained the character of middle-ear epithelial cells. A high proportion of EGFP-expressing cells were found in the recipient middle-ear after transplantation with PuraMatrix, but not without PuraMatrix. These cells retained normal morphology and function, as confirmed by histological examination, immunohistochemistry, and electron microscopy, and multiplied to form new epithelial and subepithelial layers together with basement membrane. The present study demonstrated the feasibility of transplantation of cultured middle-ear mucosal epithelial cells encapsulated within PuraMatrix for regeneration of surgically eliminated mucosa of the middle-ear in SD rats. PMID:23926427
Akiyama, Naotaro; Yamamoto-Fukuda, Tomomi; Takahashi, Haruo; Koji, Takehiko
2013-01-01
Middle-ear mucosa maintains middle-ear pressure. However, the majority of surgical cases exhibit inadequate middle-ear mucosal regeneration, and mucosal transplantation is necessary in such cases. The aim of the present study was to assess the feasibility of transplantation of isolated mucosal cells encapsulated within synthetic self-assembling peptide nanofiber scaffolds using PuraMatrix, which has been successfully used as scaffolding in tissue engineering, for the repair of damaged middle-ear. Middle-ear bullae with mucosa were removed from Sprague Dawley (SD) transgenic rats, transfected with enhanced green fluorescent protein (EGFP) transgene and excised into small pieces, then cultured up to the third passage. After surgical elimination of middle-ear mucosa in SD recipient rats, donor cells were encapsulated within PuraMatrix and transplanted into these immunosuppressed rats. Primary cultured cells were positive for pancytokeratin but not for vimentin, and retained the character of middle-ear epithelial cells. A high proportion of EGFP-expressing cells were found in the recipient middle-ear after transplantation with PuraMatrix, but not without PuraMatrix. These cells retained normal morphology and function, as confirmed by histological examination, immunohistochemistry, and electron microscopy, and multiplied to form new epithelial and subepithelial layers together with basement membrane. The present study demonstrated the feasibility of transplantation of cultured middle-ear mucosal epithelial cells encapsulated within PuraMatrix for regeneration of surgically eliminated mucosa of the middle-ear in SD rats.
Kontorinis, Georgios; Goetz, Friedrich; Lanfermann, Heinrich; Luytenski, Stefan; Giesemann, Anja M
2014-08-01
As patients with Waardenburg syndrome (WS) represent potential candidates for cochlear implantation, their inner ear anatomy is of high significance. There is an ongoing debate whether WS is related to any inner ear dysplasias. Our objective was to evaluate radiologically the inner ear anatomy in patients with WS and identify any temporal bone malformations. A retrospective case review was carried out in a tertiary, referral center. The high resolution computed tomography (HRCT) scans of the temporal bone from 20 patients (40 ears) with WS who were managed for deafness in a tertiary referral center from 1995 to 2012 were retrospectively examined. Measurements of 15 different inner ear dimensions, involving the cochlea, the vestibule, the semicircular canals and the internal auditory meatus, as well as measurements of the vestibular aqueduct, were performed independently by two neuroradiologists. Finally, we compared the results from the WS group with a control group consisting of 50 normal hearing subjects (100 ears) and with previously reported normative values. Inner ear malformations were not found in any of the patients with WS. All measured inner ear dimensions were within the normative values compiled by our study group as well as by others. Inner ear malformations are not characteristic for all types of WS; however, certain rare subtypes might be related to inner ear deformities. Normative cochleovestibular dimensions that can help in assessing the temporal bone anatomy are provided. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Keefe, Douglas H; Archer, Kelly L; Schmid, Kendra K; Fitzpatrick, Denis F; Feeney, M Patrick; Hunter, Lisa L
2017-10-01
Otosclerosis is a progressive middle-ear disease that affects conductive transmission through the middle ear. Ear-canal acoustic tests may be useful in the diagnosis of conductive disorders. This study addressed the degree to which results from a battery of ear-canal tests, which include wideband reflectance, acoustic stapedius muscle reflex threshold (ASRT), and transient evoked otoacoustic emissions (TEOAEs), were effective in quantifying a risk of otosclerosis and in evaluating middle-ear function in ears after surgical intervention for otosclerosis. To evaluate the ability of the test battery to classify ears as normal or otosclerotic, measure the accuracy of reflectance in classifying ears as normal or otosclerotic, and evaluate the similarity of responses in normal ears compared with ears after surgical intervention for otosclerosis. A quasi-experimental cross-sectional study incorporating case control was used. Three groups were studied: one diagnosed with otosclerosis before corrective surgery, a group that received corrective surgery for otosclerosis, and a control group. The test groups included 23 ears (13 right and 10 left) with normal hearing from 16 participants (4 male and 12 female), 12 ears (7 right and 5 left) diagnosed with otosclerosis from 9 participants (3 male and 6 female), and 13 ears (4 right and 9 left) after surgical intervention from 10 participants (2 male and 8 female). Participants received audiometric evaluations and clinical immittance testing. Experimental tests performed included ASRT tests with wideband reference signal (0.25-8 kHz), reflectance tests (0.25-8 kHz), which were parameterized by absorbance and group delay at ambient pressure and at swept tympanometric pressures, and TEOAE tests using chirp stimuli (1-8 kHz). ASRTs were measured in ipsilateral and contralateral conditions using tonal and broadband noise activators. Experimental ASRT tests were based on the difference in wideband-absorbed sound power before and after presenting the activator. Diagnostic accuracy to classify ears as otosclerotic or normal was quantified by the area under the receiver operating characteristic curve (AUC) for univariate and multivariate reflectance tests. The multivariate predictor used a small number of input reflectance variables, each having a large AUC, in a principal components analysis to create independent variables and followed by a logistic regression procedure to classify the test ears. Relative to the results in normal ears, diagnosed otosclerosis ears more frequently showed absent TEOAEs and ASRTs, reduced ambient absorbance at 4 kHz, and a different pattern of tympanometric absorbance and group delay (absorbance increased at 2.8 kHz at the positive-pressure tail and decreased at 0.7-1 kHz at the peak pressure, whereas group delay decreased at positive and negative-pressure tails from 0.35-0.7 kHz, and at 2.8-4 kHz at positive-pressure tail). Using a multivariate predictor with three reflectance variables, tympanometric reflectance (AUC = 0.95) was more accurate than ambient reflectance (AUC = 0.88) in classifying ears as normal or otosclerotic. Reflectance provides a middle-ear test that is sensitive to classifying ears as otosclerotic or normal, which may be useful in clinical applications. American Academy of Audiology
... of the ear drum or eustachian tube, Down Syndrome, cleft palate, and barotrauma (injury to the middle ear caused by a reduction of air pressure, ... specialist) may be warranted if you or your child has experienced repeated ... fluid in the middle ear, barotrauma, or have an anatomic abnormality that ...
Use of infrared emission detection thermometer in Chinese neonates.
Ng, D K; Liu, Y S; Ho, J C
1999-07-01
To evaluate the reproducibility of Thermoscan, an infrared emission detection ear thermometer, and to establish the normal reference range of ear temperature in Chinese neonates. Neonates were recruited from the inpatients population with exclusion of those suffering from infections. Forty-nine neonates were recruited with 1,115 temperature taking sessions. Mean left ear temperature was 36.64 degrees C +/- 0.35 degree C. Mean right ear temperature was 36.64 degrees C +/- 0.37 degree C. Clinical repeatability for left and right ear was 0.17 degree C and 0.17 degree C, respectively. Thermoscan produced reproducible results in Chinese neonates. The normal range of ear temperature for Chinese neonates is 35 degrees C to 37 degrees C. Ear temperature > 37.8 degrees C should be regarded as fever.
Audiometric Predictions Using SFOAE and Middle-Ear Measurements
Ellison, John C.; Keefe, Douglas H.
2006-01-01
Objective The goals of the study are to determine how well stimulus-frequency otoacoustic emissions (SFOAEs) identify hearing loss, classify hearing loss as mild or moderate-severe, and correlate with pure-tone thresholds in a population of adults with normal middle-ear function. Other goals are to determine if middle-ear function as assessed by wideband acoustic transfer function (ATF) measurements in the ear canal account for the variability in normal thresholds, and if the inclusion of ATFs improves the ability of SFOAEs to identify hearing loss and predict pure-tone thresholds. Design The total suppressed SFOAE signal and its corresponding noise were recorded in 85 ears (22 normal ears and 63 ears with sensorineural hearing loss) at octave frequencies from 0.5 – 8 kHz using a nonlinear residual method. SFOAEs were recorded a second time in three impaired ears to assess repeatability. Ambient-pressure ATFs were obtained in all but one of these 85 ears, and were also obtained from an additional 31 normal-hearing subjects in whom SFOAE data were not obtained. Pure-tone air-and bone-conduction thresholds and 226-Hz tympanograms were obtained on all subjects. Normal tympanometry and the absence of air-bone gaps were used to screen subjects for normal middle-ear function. Clinical decision theory was used to assess the performance of SFOAE and ATF predictors in classifying ears as normal or impaired, and linear regression analysis was used to test the ability of SFOAE and ATF variables to predict the air-conduction audiogram. Results The ability of SFOAEs to classify ears as normal or hearing impaired was significant at all test frequencies. The ability of SFOAEs to classify impaired ears as either mild or moderate-severe was significant at test frequencies from 0.5 to 4 kHz. SFOAEs were present in cases of severe hearing loss. SFOAEs were also significantly correlated with air-conduction thresholds from 0.5 to 8 kHz. The best performance occurred using the SFOAE signal-to-noise ratio (S/N) as the predictor, and the overall best performance was at 2 kHz. The SFOAE S/N measures were repeatable to within 3.5 dB in impaired ears. The ATF measures explained up to 25% of the variance in the normal audiogram; however, ATF measures did not improve SFOAEs predictors of hearing loss except at 4 kHz. Conclusions In common with other OAE types, SFOAEs are capable of identifying the presence of hearing loss. In particular, SFOAEs performed better than distortion-product and click-evoked OAEs in predicting auditory status at 0.5 kHz; SFOAE performance was similar to that of other OAE types at higher frequencies except for a slight performance reduction at 4 kHz. Because SFOAEs were detected in ears with mild to severe cases of hearing loss they may also provide an estimate of the classification of hearing loss. Although SFOAEs were significantly correlated with hearing threshold, they do not appear to have clinical utility in predicting a specific behavioral threshold. Information on middle-ear status as assessed by ATF measures offered minimal improvement in SFOAE predictions of auditory status in a population of normal and impaired ears with normal middle-ear function. However, ATF variables did explain a significant fraction of the variability in the audiograms of normal ears, suggesting that audiometric thresholds in normal ears are partially constrained by middle-ear function as assessed by ATF tests. PMID:16230898
49 CFR 227.109 - Audiometric testing program.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Measurements of background sound pressure levels in the audiometric test room as required in appendix D of this... occupational noise in excess of the action level. Hearing protectors may be used as a substitute for the... railroad shall notify its employees of the need to avoid high levels of non-occupational noise exposure...
Enhancing Intrinsic Cochlear Stress Defenses to Reduce Noise-Induced Hearing Loss
2002-09-01
trauma were wearing hearing protection when the hearing loss causing the accident took place. Poor fit of the protector will further degrade ...acetylcysteine and oral me- thionine in paracetamol poisoning. S Afr Med J 1986;60: 279. 133. Di Rocco A, Tagliati M, Danisi F, et al. A pilot study
33 CFR 150.609 - When is eye and face protection required?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false When is eye and face protection... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Eyes and Face § 150.609 When is eye and face protection required? The operator must provide eye and face protectors...
33 CFR 150.609 - When is eye and face protection required?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false When is eye and face protection... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Eyes and Face § 150.609 When is eye and face protection required? The operator must provide eye and face protectors...
Coping Strategies Title I Teachers Use to Manage Burnout and Stress: A Multisite Case Study
ERIC Educational Resources Information Center
Jeter, Lisa
2013-01-01
Teacher burnout contributes to poor psychological and physical health, absenteeism, early retirement, and leads to inadequate teacher performance with adverse outcomes in student learning and achievement. Effective coping skills have been proposed as possible protectors from the effects of burnout; therefore, examining teachers' coping resources…
Defense.gov Special Report: Travels with Gates - June 2011
Endorses Decision to Extend Libya Operation Through Early Fall BRUSSELS, June 8, 2011 - NATO Secretary Operation Unified Protector in Libya by 90 days. Story Gates Says Coalition, Afghans Can Turn Corner in Available jobs with DOD Top Issues Targeted Operations Against ISIL Terrorists Operation Atlantic Resolve
30 CFR 62.173 - Follow-up evaluation when an audiogram is invalid.
Code of Federal Regulations, 2011 CFR
2011-07-01
... invalid. 62.173 Section 62.173 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR UNIFORM MINE HEALTH REGULATIONS OCCUPATIONAL NOISE EXPOSURE § 62.173 Follow-up evaluation when an... occupational exposure to noise or the wearing of hearing protectors, the mine operator must refer the miner for...
30 CFR 62.173 - Follow-up evaluation when an audiogram is invalid.
Code of Federal Regulations, 2010 CFR
2010-07-01
... invalid. 62.173 Section 62.173 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR UNIFORM MINE HEALTH REGULATIONS OCCUPATIONAL NOISE EXPOSURE § 62.173 Follow-up evaluation when an... occupational exposure to noise or the wearing of hearing protectors, the mine operator must refer the miner for...
Right to Manage Children's Property in Iranian Positive Law
ERIC Educational Resources Information Center
Esfehanian, Ali
2017-01-01
Due to body and mind weakness and inability, children are prohibited from managing their own property and have been under tutelage and guardianship for comprehensive care and support so that all matters and issues related to them (maintenance, training, education and management of property) have been assigned to their supervisor and protector;…
Student Rights and Freedoms: Toward Implementation Models.
ERIC Educational Resources Information Center
Collins, Charles C.
Faculty, administration, and the board of trustees are dubious champions of student rights and freedoms. Without reliable protectors within the academic community, students have the options of securing their rights and freedoms by (1) the exercise of raw power, (2) finding a means to participate in the decision making process, or (3) seeking…
33 CFR 150.609 - When is eye and face protection required?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false When is eye and face protection... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Eyes and Face § 150.609 When is eye and face protection required? The operator must provide eye and face protectors...
33 CFR 150.609 - When is eye and face protection required?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false When is eye and face protection... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Eyes and Face § 150.609 When is eye and face protection required? The operator must provide eye and face protectors...
33 CFR 150.609 - When is eye and face protection required?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false When is eye and face protection... SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Workplace Safety and Health Eyes and Face § 150.609 When is eye and face protection required? The operator must provide eye and face protectors...
Solid Waste Educational Resources and Activities: Let's Reduce, Reuse, and Recycle. [CD-ROM].
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Solid Waste and Emergency Response.
This contains games, activities, publications, and resources for students and teachers on how to reduce, reuse, recycle, and properly manage waste. It also contains a screen saver featuring runners-up from the Earth Day 2000 art contest. Activities and games include titles such as "Planet Protectors,""Recycle City,""Trash…
ERIC Educational Resources Information Center
Panter, Suzanna L.
2015-01-01
School librarians act as servants of the school community and protectors of students' rights, and it is the ethical duty of school librarians to champion student privacy and resist threats to it. This article addresses the legality of this process based upon the 2007 article "How Does the Family Rights and Privacy Act [FERPA] Affect You"…
50 CFR 21.45 - Depredation order for depredating purple gallinules in Louisiana.
Code of Federal Regulations, 2014 CFR
2014-10-01
... committing or about to commit serious depredations to growing rice crops on the premises owned or occupied by... shall permit at all reasonable times, including during actual operations, any Federal or State game or deputy game agent, warden, protector, or other game law enforcement officer free and unrestricted access...
50 CFR 21.45 - Depredation order for depredating purple gallinules in Louisiana.
Code of Federal Regulations, 2010 CFR
2010-10-01
... committing or about to commit serious depredations to growing rice crops on the premises owned or occupied by... shall permit at all reasonable times, including during actual operations, any Federal or State game or deputy game agent, warden, protector, or other game law enforcement officer free and unrestricted access...
50 CFR 21.45 - Depredation order for depredating purple gallinules in Louisiana.
Code of Federal Regulations, 2013 CFR
2013-10-01
... committing or about to commit serious depredations to growing rice crops on the premises owned or occupied by... shall permit at all reasonable times, including during actual operations, any Federal or State game or deputy game agent, warden, protector, or other game law enforcement officer free and unrestricted access...
50 CFR 21.45 - Depredation order for depredating purple gallinules in Louisiana.
Code of Federal Regulations, 2012 CFR
2012-10-01
... committing or about to commit serious depredations to growing rice crops on the premises owned or occupied by... shall permit at all reasonable times, including during actual operations, any Federal or State game or deputy game agent, warden, protector, or other game law enforcement officer free and unrestricted access...
Protecting the protectors of wilderness
Juan Carlos Gambarotta
2007-01-01
Preserving the last remnants of wild country requires effective legislation, adequate finances, and appropriate policies, but in addition it requires the permanent presence of dedicated park rangers. For the International Ranger Federation, a ranger is a person who works in protected areas, and, among other tasks, is responsible for the protection of the natural and...
Television Reporters and Producers as Journalists.
ERIC Educational Resources Information Center
Smith, Conrad; Becker, Lee B.
According to a new myth in the television broadcasting industry, the producer has become the representative of the show business side of news production, while the reporter has remained the protector of the more noble goals of journalism in the television newsroom. To explore the dimensions of this myth, a study examined data, available from a…
USDA-ARS?s Scientific Manuscript database
To understand the effect of cryo-protectors on water mobility in frozen dough and bread during storage, transverse relaxation (T2) of protons was measured inside the magnet of a pulsed, low field 1H nuclear magnetic resonance (NMR) instrument. Using NMR, the three-component model was found to repres...
Biocompatibility of Liposome Nanocarriers in the Rat Inner Ear After Intratympanic Administration
NASA Astrophysics Data System (ADS)
Zou, Jing; Feng, Hao; Sood, Rohit; Kinnunen, Paavo K. J.; Pyykko, Ilmari
2017-05-01
Liposome nanocarriers (LPNs) are potentially the future of inner ear therapy due to their high drug loading capacity and efficient uptake in the inner ear after a minimally invasive intratympanic administration. However, information on the biocompatibility of LPNs in the inner ear is lacking. The aim of the present study is to document the biocompatibility of LPNs in the inner ear after intratympanic delivery. LPNs with or without gadolinium-tetra-azacyclo-dodecane-tetra-acetic acid (Gd-DOTA) were delivered to the rats through transtympanic injection. The distribution of the Gd-DOTA-containing LPNs in the middle and inner ear was tracked in vivo using MRI. The function of the middle and inner ear barriers was evaluated using gadolinium-enhanced MRI. The auditory function was measured using auditory brainstem response (ABR). The potential inflammatory response was investigated by analyzing glycosaminoglycan and hyaluronic acid secretion and CD44 and TLR2 expression in the inner ear. The potential apoptosis was analyzed using terminal transferase (TdT) to label the free 3'OH breaks in the DNA strands of apoptotic cells with TMR-dUTP (TUNEL staining). As a result, LPNs entered the inner ear efficiently after transtympanic injection. The transtympanic injection of LPNs with or without Gd-DOTA neither disrupted the function of the middle and inner ear barriers nor caused hearing impairment in rats. The critical inflammatory biological markers in the inner ear, including glycosaminoglycan and hyaluronic acid secretion and CD44 and TLR2 expression, were not influenced by the administration of LPNs. There was no significant cell death associated with the administration of LPNs. The transtympanic injection of LPNs is safe for the inner ear, and LPNs may be applied as a drug delivery matrix in the clinical therapy of sensorineural hearing loss.
Modulation by glycyrrhetinic acid derivatives of TPA-induced mouse ear oedema.
Inoue, H.; Mori, T.; Shibata, S.; Koshihara, Y.
1989-01-01
1. The anti-inflammatory effects of glycyrrhetinic acid and its derivatives on TPA (12-O-tetradecanoylphorbol-13-acetate)-induced mouse ear oedema were studied. The mechanisms of TPA-induced ear oedema were first investigated with respect to the chemical mediators. 2. The formation of ear oedema reached a maximum 5 h after TPA application (2 micrograms per ear) and the prostaglandin E2 (PGE2) production of mouse ear increased with the oedema formation. 3. TPA-induced ear oedema was prevented by actinomycin D and cycloheximide (0.1 mg per ear, respectively) when applied during 60 min after TPA treatment. 4. Of glycyrrhetinic acid derivatives examined, dihemiphthalate derivatives (IIe, IIe', IIIa, IIIa', IVa, IVa') most strongly inhibited ear oedema on both topical (ID50, 1.6 mg per ear for IIe, 2.0 mg per ear for IIIa and 1.6 mg per ear for IVa) and oral (ID50, 88 mg kg-1 for IIe', 130 mg kg-1 for IIIa' and 92 mg kg-1 for IVa') administration. 5. Glycyrrhetinic acid (Ia) and its derivatives applied 30 min before TPA treatment were much more effective in inhibiting oedema than when applied 30 min after TPA. A dihemiphthalate of triterpenoid compound IVa completely inhibited oedema, even when applied 3 h before TPA treatment. 6. Glycyrrhetinic acid (Ia) and deoxoglycyrrhetol (IIa), the parent compounds, produced little inhibition by oral administration at less than 200 mg kg-1. 7. These results suggest that the dihemiphthalate derivatives of triterpenes derived from glycyrrhetinic acid by chemical modification are useful for the treatment of skin inflammation by both topical and oral application. PMID:2924072
Munro, K J; Hatton, N
2000-02-01
The purpose of the study was to evaluate the validity of predicting the real-ear aided response by adding customized acoustic transform functions to the performance of a hearing aid in a 2-cc coupler. The real-ear hearing aid response, the real-ear-to-coupler difference (RECD/HA2), and field to behind-the-ear microphone transfer functions were measured in both ears of 24 normally hearing subjects using probe-tube microphone equipment. The RECD/HA2 transform function was obtained using both insert earphones and with the hearing aid/ pressure comparison method. An RECD/HA2 transfer function was also obtained with a customized earmold, ER-3A foam tip, and an oto-admittance tip. Validity estimates were calculated as the difference between the derived and measured real-ear response. The derived response was generally within 5 dB of the measured real-ear response when it incorporated an RECD/HA2 transform function obtained with a customized earmold for the specific ear in question. Discrepancies increased when the RECD/HA2 transfer function was obtained from the same subject but the opposite ear. There were significant differences between the RECD/HA2 transform function obtained with customized and temporary earmolds. As a result, the derived response incorporating these transforms differed significantly from the measured real-ear response obtained with the customized earmold. The insert earphone and the hearing aid RECD/HA2 transfer function were equally valid. The derived response may be used as a substitute for in situ hearing aid response procedures when it incorporates acoustic transform functions obtained with a customized earmold from the specific ear in question.
Altered Expression of Middle and Inner Ear Cytokines in Mouse Otitis Media
MacArthur, Carol J.; Pillers, De-Ann M.; Pang, Jiaqing; Kempton, J. Beth; Trune, Dennis R.
2010-01-01
Objectives/Hypothesis The inner ear is at risk for sensorineural hearing loss in both acute and chronic otitis media (OM), but the underlying mechanisms underlying sensorineural hearing loss are unknown. Previous gene expression array studies showed cytokine genes might be upregulated in the cochleas of mice with acute and chronic otitis media. This implies that the inner ear could manifest a direct inflammatory response to OM that may cause sensorineural damage. Therefore, to better understand inner ear cytokine gene expression during OM, quantitative RT-PCR and immunohistochemistry were performed on mouse models to evaluate middle and inner ear inflammatory and remodeling cytokines. Study Design Basic science experiment. Methods An acute OM model was created in Balb/c mice by a transtympanic injection of S. pneumoniae in one ear; the other ear used as a control. C3H/HeJ mice were screened for unilateral chronic OM with the non-infected ear serving as control. Results Both acute and chronic OM caused both the middle ear and inner tissues in these two mouse models to over express numerous cytokine genes related to tissue remodeling (TNFα, FGF, BMP) and angiogenesis (VEGF), as well as inflammatory cell proliferation (IL-1α,β, IL-2, IL-6). Immunohistochemistry confirmed that both the middle ear and inner ear tissues expressed these cytokines. Conclusion Cochlear tissues are capable of expressing cytokine mRNA that contributes to the inflammation and remodeling that occur in association with middle ear disease. This provides a potential molecular basis for the transient and permanent sensorineural hearing loss often reported with acute and chronic OM. Level of Evidence N/A PMID:21271590
Cozma, Romică Sebastian; Dima-Cozma, Lucia Corina; Rădulescu, Luminiţa Mihaela; Hera, Maria Cristina; Mârţu, Cristian; Olariu, Raluca; Cobzeanu, Bogdan Mihail; Bitere, Oana Roxana; Cobzeanu, Mihail Dan
2018-01-01
Patients with hearing loss who underwent cochlear implantation can present symptomatic or asymptomatic vestibular damages earlier or later after the surgery. The vestibular permanent lesions could be acute, produced by surgical trauma or could be progressive due to local morphological changes made by the presence of the portelectrode in the inner ear (fibrosis related, ossification, basilar membrane distortion, endolymphatic hydrops). Besides histopathological findings in inner ear of cochlear implanted patients, the vestibular permanent damages could be found by assessment of clinical vestibular status. This study reports the sensorial vestibular functional findings for adults in cochlear implanted ears related to the electrode insertion type (cochleostomy or round window approach) and comparing to non-implanted deaf ears. A total of 20 adult patients with 32 cochlear implanted ears (12 patients with binaural cochlear implant and eight with monoaural) were selected for postoperatory vestibular examination by cervical and ocular vestibular myogenic potentials and vestibular caloric tests. The same tests were made for a control group of 22 non-implanted deaf ears. Functional testing results were reported related to the electrode insertion approach. For the cochleostomy group, we found different deficits: in 40% for saccular function, 44% for utricular function, and 12% horizontal canal dysfunction. In round window group, the deficit was present in 14.29% for saccular function, 28.57% for utricular function, and 28.58% for horizontal canal. In 46.88% of implanted ears, the vestibular function was completely preserved on all tested sensors. In conclusion, the vestibular functional status after inner ear surgery presents sensorial damages in 53.12% ears compare with the vestibular dysfunction existing in 50% of deaf non-operated ears. Round window insertion allows for better conservation of the vestibular function.
Zou, Jing; Hannula, Markus; Misra, Superb; Feng, Hao; Labrador, Roberto Hanoi; Aula, Antti S; Hyttinen, Jari; Pyykkö, Ilmari
2015-01-27
Silver nanoparticles (Ag NPs) displayed strong activities in anti-bacterial, anti-viral, and anti-fungal studies and were reportedly efficient in treating otitis media. Information on distribution of AgNPs in different compartments of the ear is lacking. To detect distribution of Ag NPs in the middle and inner ear and transportation pathways after transtympanic injection. Contrast effect of Ag NPs in the micro CT imaging was assessed in a phantom. AgNPs at various concentrations (1.85 mM, 37.1 mM, and 370.7 mM) were administered to rat middle ear using transtympanic injection and cadaver heads were imaged using micro CT at several time points. The lowest concentration of Ag NPs that could be visualized using micro CT was 37.1 mM. No difference was observed between the solvents, deionized H2O and saline. Ag NPs at 37.1 mM were visible in the middle ear on 7 d post-administration. Ag NPs at 370.7 mM generated signals in the middle ear, ossicular chain, round window membrane, oval window, scala tympani, and Eustachian tube for both 4 h and 24 h time points. A gradient distribution of Ag NPs from the middle ear to the inner ear was detected. The pathways for Ag NPs to be transported from the middle ear into the inner ear are round and oval windows. This study provided the imaging evidence that Ag NPs are able to access the inner ear in a dose-dependent manner after intratympanic administration, which is relevant to design the delivery concentration in the future clinic application in order to avoid adverse inner ear effect.
Auditory Evoked Potential Mismatch Negativity in Normal-Hearing Adults
Schwade, Laura Flach; Didoné, Dayane Domeneghini; Sleifer, Pricila
2017-01-01
Introduction Mismatch Negativity (MMN) corresponds to a response of the central auditory nervous system. Objective The objective of this study is to analyze MMN latencies and amplitudes in normal-hearing adults and compare the results between ears, gender and hand dominance. Methods This is a cross-sectional study. Forty subjects participated, 20 women and 20 men, aged 18 to 29 years and having normal auditory thresholds. A frequency of 1000Hz (standard stimuli) and 2000Hz (deviant stimuli) was used to evoked the MMN. Results Mean latencies in the right ear were 169.4ms and 175.3ms in the left ear, with mean amplitudes of 4.6µV in the right ear and 4.2µV in the left ear. There was no statistically significant difference between ears. The comparison of latencies between genders showed a statistically significant difference for the right ear, being higher in the men than in women. There was no significant statistical difference between ears for both right-handed and left-handed group. However, the results indicated that the latency of the right ear was significantly higher for the left handers than the right handers. We also found a significant result for the latency of the left ear, which was higher for the right handers. Conclusion It was possible to obtain references of values for the MMN. There are no differences in the MMN latencies and amplitudes between the ears. Regarding gender, the male group presented higher latencies in relation to the female group in the right ear. Some results indicate that there is a significant statistical difference of the MMN between right- and left-handed individuals. PMID:28680490
NASA Astrophysics Data System (ADS)
Liliawati, W.; Utama, J. A.; Ramalis, T. R.; Rochman, A. A.
2018-03-01
Validation of the Earth and Space Science learning the material in the chapter of the Earth's Protector based on experts (media & content expert and practitioners) and junior high school students' responses are presented. The data came from the development phase of the 4D method (Define, Design, Develop, Dissemination) which consist of two steps: expert appraisal and developmental testing. The instrument employed is rubric of suitability among the book contents with multiple intelligences activities, character education, a standard of book assessment, a questionnaires and close procedure. The appropriateness of the book contents with multiple intelligences, character education and standard of book assessment is in a good category. Meanwhile, students who used the book in their learning process gave a highly positive response; the book was easy to be understood. In general, the result of cloze procedure indicates high readability of the book. As our conclusion is the book chapter of the Earth's Protector can be used as a learning material accommodating students’ multiple intelligences and character internalization.
Materials for occupational eye protectors.
Dain, Stephen J
2012-03-01
The selection of lens materials for non-prescription personal protective equipment has been a relatively simple process and has its origins in many studies around the 1970s. The viable materials available at that time were tempered glass, hard resin (n = 1.50) and polycarbonate. The modern spectacle non-prescription eye protector of choice is inevitably hard coated polycarbonate, which has exemplary impact resistant properties. In the prescription lens area, there is a bewildering array of materials of various refractive indices with a variety of coatings. The selection of an ophthalmic lens has optical and cosmetic considerations ahead of impact resistance. In complying with the Australian/New Zealand standard on prescription eye protection, adequate impact resistance must rate as the foremost requirement, with optical and cosmetic considerations as important but lesser considerations. In this review, the evidence on impact resistance of the available materials is presented, the standards set for testing impact resistance are detailed and some guidance is provided for the selection of prescription eye protection materials. © 2012 The Author. Clinical and Experimental Optometry © 2012 Optometrists Association Australia.
Tian, Yanjing; Zhou, Huifang; Zhang, Jing; Yang, Dong; Xu, Yi; Guo, Yuxi
2012-10-01
To compare the effect of rehabilitation of prelingual deaf children who used a cochlear implant (CI) in one ear and a hearing aids in the opposite ear while the hearing level of the opposite ears are different. Hearing ability, language ability and learning ability was included in the content. The aim of this research is to investigate better style of rehabilitation, and to offer the best help to the prelingual deaf children. Accord ing to the hearing level of the ear opposite to the one wearing a cochlear implant and whether the opposite ear wear a hearing aid or not, 30 prelingual deaf children were divided into three groups, including cochlear implant with opposite severe hearing loss and hearing aid ear (CI+SHA), cochlear implant with opposite profound hearing loss and hearing aid ear (CI+PHA), cochlear implant only (CI). The effect of rehabilitation was assessed in six different times (3,6,9,12,15 and 18 months after the cochlear implants and hearing aids began to work). The longer time the rehabilitation spends, the better the hearing ability,language ability and the learning ability were. The hearing ability of CI+SHA was better than those of CI+PHA (P<0.05) and CI (P<0.05). The language ability and learning ability of CI-SHA was nearly equal to those of the other two groups. The prelingual deaf children should take much more time on rehabilitation. The effect of rehabilitation for prelingual deaf children who used cochlear implant in one ear and hearing aid in the other depend on the residual hearing level of the other ear. If a prelingual deaf children still has any residual hearing level in the ear opposite to the cochlear implant ear, it is better for him/her to wear a hearing aid in the ear.
21 CFR 874.4420 - Ear, nose, and throat manual surgical instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
... device includes the esophageal dilator; tracheal bistour (a long, narrow surgical knife); tracheal dilator; tracheal hook; laryngeal injection set; laryngeal knife; laryngeal saw; laryngeal trocar...; wire ear loop; microrule; mirror; mobilizer; ear, nose, and throat punch; ear, nose and throat knife...
Rado-Triveño, Julia; Alen-Ayca, Jaime
2016-01-01
To determine the validity of the use of acoustic otoacoustic emissions in comparison with the evoked potentials Auditory brainstem examination (PEATC), a study was carried out with 96 children between 0 and 4 years of age that went to Instituto Nacional de Rehabilitación in Lima, Peru. The results show a cut-off point corresponding to 1 in (+): 17.67 in right ear and 16.72 in left ear, and LR (-): 0.25 in ear right and 0.24 in left ear; ROC curve with area under the right ear curve of 0.830 (p<0.001) was obtained and in left ear of 0.829 (p<0.001). According to the results of LR (+) the sensitivity is 76% in the right ear and 65% In the left ear that coincides with the conformation of the ROC curve. In conclusion, acoustic emissions would not represent an alternative sufficiently discriminatory alternative as a screening test in this population.
Modeling Analysis of Biomechanical Changes of Middle Ear and Cochlea in Otitis Media
NASA Astrophysics Data System (ADS)
Gan, Rong Z.; Zhang, Xiangming; Guan, Xiying
2011-11-01
A comprehensive finite element (FE) model of the human ear including the ear canal, middle ear, and spiral cochlea was developed using histological sections of human temporal bone. The cochlea was modeled with three chambers separated by the basilar membrane and Reissner's membrane and filled with perilymphatic fluid. The viscoelastic material behavior was applied to middle ear soft tissues based on dynamic measurements of tissues in our lab. The model was validated using the experimental data obtained in human temporal bones and then used to simulate various stages of otitis media (OM) including the changes of morphology, mechanical properties, pressure, and fluid level in the middle ear. Function alterations of the middle ear and cochlea in OM were derived from the model and compared with the measurements from temporal bones. This study indicates that OM can be simulated in the FE model to predict the hearing loss induced by biomechanical changes of the middle ear and cochlea.
Fritzsch, Bernd; Beisel, Kirk W.; Hansen, Laura
2014-01-01
Summary The inner ear of mammals uses neurosensory cells derived from the embryonic ear for mechanoelectric transduction of vestibular and auditory stimuli (the hair cells) and conducts this information to the brain via sensory neurons. As with most other neurons of mammals, lost hair cells and sensory neurons are not spontaneously replaced and result instead in age-dependent progressive hearing loss. We review the molecular basis of neurosensory development in the mouse ear to provide a blueprint for possible enhancement of therapeutically useful transformation of stem cells into lost neurosensory cells. We identify several readily available adult sources of stem cells that express, like the ectoderm-derived ear, genes known to be essential for ear development. Use of these stem cells combined with molecular insights into neurosensory cell specification and proliferation regulation of the ear, might allow for neurosensory regeneration of mammalian ears in the near future. PMID:17120192
Musical ear syndrome in adult cochlear implant patients.
Low, W-K; Tham, C A; D'Souza, V-D; Teng, S-W
2013-09-01
Except for a single case report, musical ear syndrome in cochlear implantees has not been studied. We aimed to study the prevalence and nature of musical ear syndrome among adult cochlear implant patients, as well as the effect on their emotional well-being. STUDY DESIGN, PATIENTS AND INTERVENTION: A cross-sectional survey of patients aged 18 years and above who had received cochlear implants for profound hearing loss between 1997 and 2010. Of the 82 patients studied, 18 (22 per cent) were found to have experienced musical ear syndrome. Seven and 11 patients had musical ear syndrome prior to and after cochlear implantation, respectively. The character of musical ear syndrome symptoms was described as instrumental music (n = 2), singing (6) or both (10). Fourteen patients reported an adverse emotional effect, with three expressing ‘intolerance’. In this study, 22 per cent of cochlear implantees experienced musical ear syndrome. These symptoms affected patients’ emotional state, but most coped well. Musical ear syndrome can occur prior to and after cochlear implantation.
Correction of Lying Ears by Augmentation of the Conchoscaphal Angle.
Kim, Sung-Eun; Yeo, Chi-Ho; Kim, Taegon; Kim, Yong-Ha; Lee, Jun Ho; Chung, Kyu-Jin
2017-01-01
Lying ears are defined as ears that protrude less from the head, and in frontal view, are characterized by lateral positioning of antihelical contour relative to the helical rim. These aesthetically displeasing ears require correction in accord with the goals of otoplasty stated by McDowell. The authors present a case of lying ears treated by correcting the conchomastoid angle using Z-plasty, resection of posterior auricular muscle, and correction of the conchoscaphal angle by releasing cartilage using 2 full-thickness incisions and grafting of a conchal cartilage spacer. By combining these techniques, the authors efficiently corrected lying ears and produced aesthetically pleasing results.
Anatomy, Physiology and Function of the Auditory System
NASA Astrophysics Data System (ADS)
Kollmeier, Birger
The human ear consists of the outer ear (pinna or concha, outer ear canal, tympanic membrane), the middle ear (middle ear cavity with the three ossicles malleus, incus and stapes) and the inner ear (cochlea which is connected to the three semicircular canals by the vestibule, which provides the sense of balance). The cochlea is connected to the brain stem via the eighth brain nerve, i.e. the vestibular cochlear nerve or nervus statoacusticus. Subsequently, the acoustical information is processed by the brain at various levels of the auditory system. An overview about the anatomy of the auditory system is provided by Figure 1.
Distortion product otoacoustic emissions upon ear canal pressurization.
Zebian, Makram; Schirkonyer, Volker; Hensel, Johannes; Vollbort, Sven; Fedtke, Thomas; Janssen, Thomas
2013-04-01
The purpose of this study was to quantify the change in distortion product otoacoustic emission (DPOAE) level upon ear canal pressurization. DPOAEs were measured on 12 normal-hearing human subjects for ear canal static pressures between -200 and +200 daPa in (50 ± 5) daPa steps. A clear dependence of DPOAE levels on the pressure was observed, with levels being highest at the maximum compliance of the middle ear, and decreasing on average by 2.3 dB per 50 daPa for lower and higher pressures. Ear canal pressurization can serve as a tool for improving the detectability of DPOAEs in the case of middle-ear dysfunction.
[Magnetic resonance imaging study and cochlear implantation in post-meningitic deaf patients].
Liu, Xiuli; Yao, Yiwen; He, Guili; Zhai, Lijie
2004-07-01
To investigate the clinical application of magnetic resonance imaging (MRI) in post-meningitic patients and its impact on surgical decision. The pre-operative MRI data and auditory brainstem response (ABR) examination of five post-meningitic patients were studied. They were implanted with cochleas. The interval between the onset of bacterial meningitis and the hearing loss was (15.8 +/- 15.0)d and it was longer in children than adults. Five ears showed membranous cochlear labyrinth abnormality; 3 ears had vestibule vestibule abnormality; 8 ears demonstrated semicircular canal abnormality on MRI examinations in totally 10 ears. The mean hearing threshold of 10 ears was (102.0 +/- 7.1)dB HL,that of the operated ears was (98.0 +/- 5.7)dB HL and that of the un-operated ears was (106.0 +/- 6.5)dB HL. It was (15.8 +/- 15.0)d from the bacterial meningitis onset to hearing loss. The interval is longer in children than adults. There were 3 ears that electrodes could not be inserted completely. The bacterial meningitis may cause the abnormalities of inner ears and the MRI before surgery is essential for the pre-operative planning of cochlear implant.
Gustatory otalgia and wet ear syndrome: a possible cross-innervation after ear surgery.
Saito, H
1999-04-01
The chorda tympani and Arnold's nerves have close approximation to each other and their cross-innervation is possible after ear surgery. A retrospective study was performed with a temporal bone pathology case and two clinical cases as representatives of such a possibility. Patients had severe otalgia and wet ear during gustatory stimulation. A temporal bone pathology case was studied under a light microscope. Earache and/or wet ear were provoked during gustatory stimulation. Wet ear was tested with iodine-starch reaction after the subject tasted lemon juice. The temporal bone specimen has clusters of regenerated fibers in the tympanic cavity in the area of the chorda tympani and Arnold's nerves, suggesting a possibility of mixing. There are regenerated fibers in the iter chordae anterius, showing successful bridging of the chorda tympani nerves across a long gap. Detachment of the skin over the operated mastoid bowl obscured signs in one clinical case. Another clinical case of gustatory wet ear showed objective evidence of cross-innervation with iodine-starch reaction. The detachment procedure and iodine-starch reaction were the proofs that the signs were related to regenerated fibers. This is the first report of gustatory otalgia and wet ear after ear surgery.
Stem Cell Therapy for the Inner Ear
Okano, Takayuki
2012-01-01
In vertebrates, perception of sound, motion, and balance is mediated through mechanosensory hair cells located within the inner ear. In mammals, hair cells are only generated during a short period of embryonic development. As a result, loss of hair cells as a consequence of injury, disease, or genetic mutation, leads to permanent sensory deficits. At present, cochlear implantation is the only option for profound hearing loss. However, outcomes are still variable and even the best implant cannot provide the acuity of a biological ear. The recent emergence of stem cell technology has the potential to open new approaches for hair cell regeneration. The goal of this review is to summarize the current state of inner ear stem cell research from a viewpoint of its clinical application for inner ear disorders to illustrate how complementary studies have the potential to promote and refine stem cell therapies for inner ear diseases. The review initially discusses our current understanding of the genetic pathways that regulate hair cell formation from inner ear progenitors during normal development. Subsequent sections discuss the possible use of endogenous inner ear stem cells to induce repair as well as the initial studies aimed at transplanting stem cells into the ear. PMID:22514095
Selective forces on origin, adaptation and reduction of tympanal ears in insects.
Strauß, Johannes; Stumpner, Andreas
2015-01-01
Insect ears evolved many times independently. As a consequence, a striking diversity exists in the location, construction and behavioural implementation of ears. In this review, we first summarise what is known about the evolutionary origin of ears and the presumed precursor organs in the various insect groups. Thereafter, we focus on selective forces for making and keeping an ear: we discuss detecting and localising predators and conspecifics, including establishing new "private" channels for intraspecific communication. More advanced aspects involve judging the distance of conspecifics, or assessing individual quality from songs which makes auditory processing a means for exerting sexual selection on mating partners. We try to identify negative selective forces, mainly in the context of energy expenditure for developing and keeping an ear, but also in conjunction with acoustic communication, which incorporates risks like eavesdropping by predators and parasitoids. We then discuss balancing pressures, which might oppose optimising an ear for a specific task (when it serves different functions, for example). Subsequently, we describe various scenarios that might have led to a reduction or complete loss of ears in evolution. Finally, we describe cases of sex differences in ears and potential reasons for their appearance.
Ear abnormalities in patients with oculo-auriculo-vertebral spectrum (Goldenhar syndrome).
Rosa, Rafael Fabiano Machado; Silva, Alessandra Pawelec da; Goetze, Thayse Bienert; Bier, Bianca de Almeida; Almeida, Sheila Tamanini de; Paskulin, Giorgio Adriano; Zen, Paulo Ricardo Gazzola
2011-01-01
Oculo-auriculo-vertebral spectrum (OAVS) is a rare condition characterized by the involvement of the first branchial arches. To investigate the ear abnormalities of a sample of patients with OAVS. The sample consisted of 12 patients with OAVS seen at the Clinical Genetics Unit, UFCSPA/CHSCPA. The study included only patients who underwent mastoid computed tomography and with normal karyotype. We performed a review of its clinical features, giving emphasis to the ear findings. Nine patients were male, the ages ranged from 1 day to 17 years. Ear abnormalities were observed in all patients and involved the external (n = 12), middle (n = 10) and inner ear (n = 3). Microtia was the most frequent finding (n = 12). The most common abnormalities of the middle ear were: opacification (n = 2), displacement (n = 2) and malformation of the ossicular chain. Agenesis of the internal auditory canal (n = 2) was the most frequent alteration of the inner ear. Ear abnormalities are variable in patients with OAVS and often there is no correlation between findings in the external, middle and inner ear. The evaluation of these structures is important in the management of individuals with OAVS.
Optical measurement of the weak non-linearity in the eardrum vibration response to auditory stimuli
NASA Astrophysics Data System (ADS)
Aerts, Johan
The mammalian hearing organ consists of the external ear (auricle and ear canal) followed by the middle ear (eardrum and ossicles) and the inner ear (cochlea). Its function is to convert the incoming sound waves and convert them into nerve pulses which are processed in the final stage by the brain. The main task of the external and middle ear is to concentrate the incoming sound waves on a smaller surface to reduce the loss that would normally occur in transmission from air to inner ear fluid. In the past it has been shown that this is a linear process, thus without serious distortions, for sound waves going up to pressures of 130 dB SPL (˜90 Pa). However, at large pressure changes up to several kPa, the middle ear movement clearly shows non-linear behaviour. Thus, it is possible that some small non-linear distortions are also present in the middle ear vibration at lower sound pressures. In this thesis a sensitive measurement set-up is presented to detect this weak non-linear behaviour. Essentially, this set-up consists of a loud-speaker which excites the middle ear, and the resulting vibration is measured with an heterodyne vibrometer. The use of specially designed acoustic excitation signals (odd random phase multisines) enables the separation of the linear and non-linear response. The application of this technique on the middle ear demonstrates that there are already non-linear distortions present in the vibration of the middle ear at a sound pressure of 93 dB SPL. This non-linear component also grows strongly with increasing sound pressure. Knowledge of this non-linear component can contribute to the improvement of modern hearing aids, which operate at higher sound pressures where the non-linearities could distort the signal considerably. It is also important to know the contribution of middle ear non-linearity to otoacoustic emissions. This are non-linearities caused by the active feedback amplifier in the inner ear, and can be detected in the external and middle ear. These signals are used for diagnostic purposes, and therefore it is important to have an estimate the non-linear middle ear contribution to these emissions.
21 CFR 870.2710 - Ear oximeter.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ear oximeter. 870.2710 Section 870.2710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2710 Ear oximeter. (a) Identification. An ear...
... Videos for Educators Search English Español Can Loud Music Hurt My Ears? KidsHealth / For Kids / Can Loud Music Hurt My Ears? Print en español La música ... up? Oh! You want to know if loud music can hurt your ears . Are you asking because ...
21 CFR 870.2710 - Ear oximeter.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear oximeter. 870.2710 Section 870.2710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2710 Ear oximeter. (a) Identification. An ear...
Natural history of hearing loss in children with enlarged vestibular aqueduct syndrome.
Mori, Tyler; Westerberg, Brian D; Atashband, Shahnaz; Kozak, Frederick K
2008-02-01
To determine the natural history of hearing loss in children with enlarged vestibular aqueduct (EVA) syndrome. (1) Retrospective cohort study and (2) systematic literature review. Tertiary pediatric centre. (1) Charts of children assessed by one physician between 1993 and 2000 were reviewed. (2) Source articles were identified by a search of Medline, Embase, and the Cochrane Library of the English-language literature through January 2006, with manual review of references. The search was limited to English, human, and age less than 18 years. Pure-tone average. Hearing was classified as stable, progressive and fluctuating. (1) Twenty-one children (39 ears) with EVA were identified. Eighty-two percent of ears had stable hearing, and 18% of ears demonstrated progressive hearing loss. (2) Seven source articles were identified and combined with the present data for a total of 310 ears with a mean follow-up of 4 years. Bilateral EVA was found to be six times more common than unilateral EVA, and there was an equal male to female ratio. Stable hearing was found in 67% of ears and progressive hearing loss in 33% of ears. Subgroup analysis demonstrated hearing fluctuations in 50% of progressive hearing loss ears and 34% of stable ears. Stable hearing is observed in 67% of ears with EVA of which 34% will demonstrate fluctuations in hearing. Progression of hearing loss is seen in 33% of ears of which half will demonstrate fluctuations.
Vitamin D receptor deficiency impairs inner ear development in zebrafish
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kwon, Hye-Joo; Biology Department, Princess Nourah University, Riyadh 11671
The biological actions of vitamin D are largely mediated through binding to the vitamin D receptor (VDR), a member of the nuclear hormone receptor family, which regulates gene expression in a wide variety of tissues and cells. Mutations in VDR gene have been implicated in ear disorders (hearing loss and balance disorder) but the mechanisms are not well established. In this study, to investigate the role of VDR in inner ear development, morpholino-mediated gene knockdown approaches were used in zebrafish model system. Two paralogs for VDR, vdra and vdrb, have been identified in zebrafish. Knockdown of vdra had no effectmore » on ear development, whereas knockdown of vdrb displayed morphological ear defects including smaller otic vesicles with malformed semicircular canals and abnormal otoliths. Loss-of-vdrb resulted in down-regulation of pre-otic markers, pax8 and pax2a, indicating impairment of otic induction. Furthermore, zebrafish embryos lacking vdrb produced fewer sensory hair cells in the ears and showed disruption of balance and motor coordination. These data reveal that VDR signaling plays an important role in ear development. - Highlights: • VDR signaling is involved in ear development. • Knockdown of vdrb causes inner ear malformations during embryogenesis. • Knockdown of vdrb affects otic placode induction. • Knockdown of vdrb reduces the number of sensory hair cells in the inner ear. • Knockdown of vdrb disrupts balance and motor coordination.« less
Keefe, Douglas H.; Hunter, Lisa L.; Feeney, M. Patrick; Fitzpatrick, Denis F.
2015-01-01
Procedures are described to measure acoustic reflectance and admittance in human adult and infant ears at frequencies from 0.2 to 8 kHz. Transfer functions were measured at ambient pressure in the ear canal, and as down- or up-swept tympanograms. Acoustically estimated ear-canal area was used to calculate ear reflectance, which was parameterized by absorbance and group delay over all frequencies (and pressures), with substantial data reduction for tympanograms. Admittance measured at the probe tip in adults was transformed into an equivalent admittance at the eardrum using a transmission-line model for an ear canal with specified area and ear-canal length. Ear-canal length was estimated from group delay around the frequency above 2 kHz of minimum absorbance. Illustrative measurements in ears with normal function are described for an adult, and two infants at 1 month of age with normal hearing and a conductive hearing loss. The sensitivity of this equivalent eardrum admittance was calculated for varying estimates of area and length. Infant-ear patterns of absorbance peaks aligned in frequency with dips in group delay were explained by a model of resonant canal-wall mobility. Procedures will be applied in a large study of wideband clinical diagnosis and monitoring of middle-ear and cochlear function. PMID:26723319
Schlicksup, Michael D; Van Winkle, Thomas J; Holt, David E
2009-10-01
To determine the prevalence of nonneoplastic middle ear disease among cats undergoing necropsy and the prevalence of clinical abnormalities in cats in which nonneoplastic middle ear disease was identified. Retrospective case series. 59 cats that underwent necropsy between January 1991 and August 2007. Medical records were searched to identify cats in which nonneoplastic middle ear disease was identified at necropsy. For cats included in the study, data that were recorded included signalment, initial complaint, whether the cat had any clinical signs of middle or external ear disease, whether the cat had upper respiratory tract disease, necropsy diagnosis, gross appearance of the bullae, and reason for euthanasia. Signs of middle ear disease that were considered included unilateral peripheral vestibular disease without motor deficits, Horner syndrome, and facial nerve paralysis. Of the 3,442 cats that underwent necropsy during the study period, 59 (1.7%) had nonneoplastic middle ear disease. Six of the 59 (10%) cats, including 1 cat that was affected bilaterally, had clinical signs of middle ear disease. Of these, 5 had signs of unilateral peripheral vestibular disease, and 1 had Horner syndrome. Results suggested that most cats with nonneoplastic middle ear disease did not have associated clinical signs. Findings may be of clinical relevance for cats in which middle ear disease is identified as an incidental finding during computed tomography or magnetic resonance imaging for unrelated diseases.
Middle-Ear Pressure Gain and Cochlear Partition Differential Pressure in Chinchilla
Ravicz, Michael E.; Slama, Michaël C.C.; Rosowski, John J.
2009-01-01
An important step to describe the effects of inner-ear impedance and pathologies on middle- and inner-ear mechanics is to quantify middle- and inner-ear function in the normal ear. We present middle-ear pressure gain GMEP and trans-cochlear-partition differential sound pressure ΔPCP in chinchilla from 100 Hz to 30 kHz derived from measurements of intracochlear sound pressures in scala vestibuli PSV and scala tympani PST and ear-canal sound pressure near the tympanic membrane PTM. These measurements span the chinchilla's auditory range. GMEP had constant magnitude of about 20 dB between 300 Hz and 20 kHz and phase that implies a 40-μs delay, values with some similarities to previous measurements in chinchilla and other species. ΔPCP was similar to GMEP below about 10 kHz and lower in magnitude at higher frequencies, decreasing to 0 dB at 20 kHz. The high-frequency rolloff correlates with the audiogram and supports the idea that middle-ear transmission limits high-frequency hearing, providing a stronger link between inner-ear macromechanics and hearing. We estimate the cochlear partition impedance ZCP from these and previous data. The chinchilla may be a useful animal model for exploring the effects of nonacoustic inner-ear stimulation such as “bone conduction” on cochlear mechanics. PMID:19945521
Malformations of the middle and inner ear on CT imaging in 22q11 deletion syndrome.
Loos, Elke; Verhaert, Nicolas; Willaert, Annelore; Devriendt, Koenraad; Swillen, Ann; Hermans, Robert; Op de Beeck, Katya; Hens, Greet
2016-11-01
The 22q11 deletion syndrome (22q11DS), the most frequent microdeletion syndrome in humans, presents with a large variety of abnormalities. A common abnormality is hearing impairment. The exact pathophysiological explanation of the observed hearing loss remains largely unknown. The aim of this study was to analyze the middle and inner ear malformations as seen on computer tomographic imaging in patients with 22q11DS. We retrospectively reviewed the charts of 11 22q11DS patients who had undergone a CT of the temporal bone in the past. Of the 22 examined ears, two showed an abnormal malleus and incus, 10 presented with a dense stapes superstructure, and three ears had an abnormal orientation of the stapes. With regard to the inner ear, 12 ears showed an incomplete partition type II with a normal vestibular aqueduct. In four ears the vestibule and lateral semicircular canal were composed of a single cavity, in 14 ears the vestibule was too wide, and three ears had a broadened lateral semicircular canal. These findings suggest that malformations of the stapes, cochlea, vestibule, and lateral semicircular canal are frequent in 22q11DS. To our knowledge, the current study involves the largest case series describing middle and inner ear malformations in 22q11DS. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Eadie, D. T.; Santoro, M.; Powell, W.
2003-10-01
Wheel squeal is a source of continuing concern for many railroads and transits, as well as for their neighbours. The underlying mechanism for squeal noise has been well understood in the literature for some time. However an integrated abatement method addressing the underlying cause of the problem has not previously been reported. This paper describes practical experience using a water-based liquid Friction Modifier (KELTRACK™) applied using a top of rail trackside applicator (Portec Protector ®). The Friction Modifier and delivery equipment have been co-developed to provide an optimized product/delivery system that gives significant reduction of wheel squeal in curves. Wheels experiencing lateral creep in curves are subject to roll-slip oscillations as a result of the frictional characteristics of the interface layer between the wheel and rail. These roll-slip oscillations are amplified in the wheel web leading to the familiar squeal. Providing a thin film of material between the wheel and rail with positive friction characteristics can both in theory and practice greatly reduce the magnitude of these oscillations. The controlled intermediate friction characteristics of KELTRACK™ allow the material to be delivered to the top of both rails without compromising traction or braking. The positive friction aspects of the friction modifier are illustrated by published laboratory studies. Delivery of KELTRACK™ to the contact patch is achieved with a proprietary top of rail electric trackside applicator, the Portec Protector ®. The material is delivered to the top of both rails for optimum friction control. The integrated product/equipment technology is now successfully controlling noise at more than twenty transit sites. Typical sound level reduction is 10-15 dB, in some cases as high as 20 dB, depending on the initial sound level. Two case studies are presented illustrating the technology.
Update on Middle Ear Barotrauma after Hyperbaric Oxygen Therapy—Insights on Pathophysiology
Lima, Marco Antônio Rios; Farage, Luciano; Cury, Maria Cristina Lancia; Bahamad, Fayez
2014-01-01
Introduction Middle ear barotrauma is the most common side effect of hyperbaric oxygen therapy. Knowledge and understanding of its pathophysiology are crucial for an accurate diagnosis and proper decision making about treatment and prevention. Objective Describe up-to-date information on pathophysiology of middle ear barotrauma after hyperbaric oxygen therapy considering the physiology of pressure variation of the middle ear. Data Synthesis Middle ear barotrauma occurs especially during the compression phase of hyperbaric oxygen therapy. The hyperoxic environment in hyperbaric oxygen therapy leads to ventilatory dysfunction of the eustachian tube, especially in monoplace chambers, where the patients are pressurized with 100% O2, favoring middle ear barotrauma. Conclusion The eustachian tube, the tympanic cavity, and mastoid work together in a neural controlled feedback system in which various mechanisms concur for middle ear pressure regulation. PMID:25992091
Ciuman, Raphael R
2009-01-01
There exist 3 communication routes between the intracranial space and the inner ear, the vestibular aqueduct, the cochlear aqueduct, and the internal auditory canal. They possess a key role in inner ear pressure regulation and fluid homeostasis and are related to inner ear diseases. Relevant literature was reviewed, and the current knowledge of the anatomy, physiologic importance, and relations to inner ear diseases were described. Pathologic communication routes such as semicircular canal dehiscence syndrome were highlighted as well. Abnormalities in all 3 communication routes may predispose or be the cause of distinct inner ear pathologic condition and involved in other cochlear and vestibular syndromes, in which their role is not completely clear. The increasing knowledge of the underlying mechanisms encourages promising approaches for possible intervention in the future.
Pauna, Henrique F.; Monsanto, Rafael C.; Schachern, Patricia A.; Costa, Sady S.; Kwon, Geeyoun; Paparella, Michael M.; Cureoglu, Sebahattin
2016-01-01
Objective Endoscopic procedures are becoming common in middle ear surgery. Inflammation due to chronic ear disease can cause bony erosion of the carotid artery and Fallopian canals, making them more vulnerable during surgery. The objective of this study was to determine whether or not chronic ear disease increases dehiscence of the carotid artery and Fallopian canals. Design Comparative human temporal bone study. Setting Otopathology laboratory. Participants We selected 78 temporal bones from 55 deceased donors with chronic otitis media or cholesteatoma, and then compared those 2 groups with a control group of 27 temporal bones from 19 deceased donors with no middle ear disease. Main outcome measures We analyzed the middle ear, carotid artery canal, and Fallopian canal, looking for signs of dehiscence of its bony coverage, using light microscopy. Results We found an increased incidence in dehiscence of the carotid artery and Fallopian canals in temporal bones with chronic middle ear disease. The size of the carotid artery canal dehiscence was larger in the middle ear diseased groups, and its bony coverage, when present, was also thinner compared to the control group. Dehiscence of the carotid artery canal was more frequently located closer to the promontory. The incidence of Fallopian canal dehiscence was significantly higher in temporal bones from donors older than 18 years with chronic middle ear disease. Conclusion The increased incidence of the carotid artery and Fallopian canal dehiscence in temporal bones with chronic middle ear disease elevates the risk of adverse events during middle ear surgery. Level of Evidence N/A. PMID:27455393
Wan, Rui; Pang, Xingyuan; Ren, Jun
2018-02-01
This case study improves an operative method of ear reconstruction for microtia patients by using a four-layer rib cartilage framework to increase transverse height of the reconstructive ear to a natural level in one operative stage. The procedures of ear reconstruction were conducted from February 2014 to May 2016. The ear framework used in the procedures was fabricated from autologous rib cartilage into a four-layer spliced sculpture. Totally 23 patients with unilateral microtia were willing to be enrolled in this study. After the operation, 23 patients achieved 2.3-2.8 cm transverse height of reconstructed ears, which was basically the same as the normal side. Both patients and their families felt satisfied with the results. Follow-up was performed at 6-16 months after the procedures. Only one case showed significantly lowered transverse height of the reconstructed ear, compared to the normal one. It was due to the sleeping position of the patient (10-year-old boy), which put the reconstructed ear under pressure and reduced the transverse height of the ear. The method of four-layer sculpted autologous rib cartilage ear reconstruction has good clinical effect. It can provide a reconstructed ear that reaches normal transverse height and avoids a third operation to increase the transverse height by rib cartilage transplantation. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Immunologic Disorders of the Inner Ear.
ERIC Educational Resources Information Center
Kinney, William C.; Hughes, Gordon B.
1997-01-01
Immune inner ear disease represents a series of immune system mediated problems that can present with hearing loss, dizziness, or both. The etiology, presentation, testing, and treatment of primary immune inner ear disease is discussed. A review of secondary immune inner ear disease is presented for comparison. (Contains references.) (Author/CR)
Ear Infections and Language Development.
ERIC Educational Resources Information Center
Roberts, Joanne E.; Zeisel, Susan A.
Ear infections in infants and preschoolers can cause mild or moderate temporary hearing loss, which may in turn affect a child's ability to understand and learn language. Noting that providing children with proper medical treatment for ear infections or middle ear fluid is important in preventing possible problems with language development, this…
Salomir, Rares; Petrusca, Lorena; Auboiroux, Vincent; Muller, Arnaud; Vargas, Maria-Isabel; Morel, Denis R; Goget, Thomas; Breguet, Romain; Terraz, Sylvain; Hopple, Jerry; Montet, Xavier; Becker, Christoph D; Viallon, Magalie
2013-06-01
The treatment of liver cancer is a major public health issue because the liver is a frequent site for both primary and secondary tumors. Rib heating represents a major obstacle for the application of extracorporeal focused ultrasound to liver ablation. Magnetic resonance (MR)-guided external shielding of acoustic obstacles (eg, the ribs) was investigated here to avoid unwanted prefocal energy deposition in the pathway of the focused ultrasound beam. Ex vivo and in vivo (7 female sheep) experiments were performed in this study. Magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU) was performed using a randomized 256-element phased-array transducer (f∼1 MHz) and a 3-T whole-body clinical MR scanner. A physical mask was inserted in the prefocal beam pathway, external to the body, to block the energy normally targeted on the ribs. The effectiveness of the reflecting material was investigated by characterizing the efficacy of high-intensity focused ultrasound beam reflection and scattering on its surface using Schlieren interferometry. Before high-intensity focused ultrasound sonication, the alignment of the protectors with the conical projections of the ribs was required and achieved in multiple steps using the embedded graphical tools of the MR scanner. Multiplanar near real-time MR thermometry (proton resonance frequency shift method) enabled the simultaneous visualization of the local temperature increase at the focal point and around the exposed ribs. The beam defocusing due to the shielding was evaluated from the MR acoustic radiation force impulse imaging data. Both MR thermometry (performed with hard absorber positioned behind a full-aperture blocking shield) and Schlieren interferometry indicated a very good energy barrier of the shielding material. The specific temperature contrast between rib surface (spatial average) and focus, calculated at the end point of the MRgHIFU sonication, with protectors vs no protectors, indicated an important reduction of the temperature elevation at the ribs' surface, typically by 3.3 ± 0.4 in vivo. This was translated into an exponential reduction in thermal dose by several orders of magnitude. The external shielding covering the full conical shadow of the ribs was more effective when the protectors could be placed close to the ribs' surface and had a tendency to lose its efficiency when placed further from the ribs. Hepatic parenchyma was safely ablated in vivo using this rib-sparing strategy and single-focus independent sonications. A readily available, MR-compatible, effective, and cost-competitive method for rib protection in transcostal MRgHIFU was validated in this study, using specific reflective strips. The current approach permitted safe intercostal ablation of small volumes (0.7 mL) of liver parenchyma.
Development of an ear cap in chronic suppurative otitis media using additive manufacturing and TRIZ.
Mawale, Mahesh B; Kuthe, Abhaykumar; Mawale, Anupama M; Dahake, Sandeep W
2018-06-01
The prevalence rate of chronic suppurative otitis media is high and its treatment continues to be a challenge for the otorhinolaryngologists. Due to middle ear infection, there may be pain, hearing loss and spontaneous rupture of the eardrum which results in perforation. Infections can cause a hole in the eardrum as a side effect of otitis media. The patients suffering from ear perforation or having a hole in eardrum require preventing entry of water in the ear. This article describes the development of ear cap using additive manufacturing and TRIZ (a collaborative tool) to prevent the entry of water in the ear during chronic otitis media.
Surgical correction of cauliflower ear.
Yotsuyanagi, T; Yamashita, K; Urushidate, S; Yokoi, K; Sawada, Y; Miyazaki, S
2002-07-01
We have classified the cauliflower ear into different types according to the zone and the degree of deformity. One major group is deformity without change in the outline of the ear, and this is divided into four subgroups according to the zone. All of these subgroups can be treated by shaving the deformed cartilage through suitable incision lines. For deformities accompanied by a skin deficit, a postauricular skin flap should be used. The other major group is deformity accompanied by a change in the outline of the ear, which is divided into two subgroups. If the ear is rigid, a conchal cartilage graft is used. If the structural integrity of the ear is poor, costal cartilage is used to provide rigidity.
Inner ear symptoms and disease: Pathophysiological understanding and therapeutic options
Ciuman, Raphael R.
2013-01-01
In recent years, huge advances have taken place in understanding of inner ear pathophysiology causing sensorineural hearing loss, tinnitus, and vertigo. Advances in understanding comprise biochemical and physiological research of stimulus perception and conduction, inner ear homeostasis, and hereditary diseases with underlying genetics. This review describes and tabulates the various causes of inner ear disease and defines inner ear and non-inner ear causes of hearing loss, tinnitus, and vertigo. The aim of this review was to comprehensively breakdown this field of otorhinolaryngology for specialists and non-specialists and to discuss current therapeutic options in distinct diseases and promising research for future therapies, especially pharmaceutic, genetic, or stem cell therapy. PMID:24362017
Biometric recognition using 3D ear shape.
Yan, Ping; Bowyer, Kevin W
2007-08-01
Previous works have shown that the ear is a promising candidate for biometric identification. However, in prior work, the preprocessing of ear images has had manual steps and algorithms have not necessarily handled problems caused by hair and earrings. We present a complete system for ear biometrics, including automated segmentation of the ear in a profile view image and 3D shape matching for recognition. We evaluated this system with the largest experimental study to date in ear biometrics, achieving a rank-one recognition rate of 97.8 percent for an identification scenario and an equal error rate of 1.2 percent for a verification scenario on a database of 415 subjects and 1,386 total probes.
Auricular anthropometry of Hong Kong Chinese babies.
Fok, T F; Hon, K L; So, H K; Ng, P C; Wong, E; Lee, A K Y; Chang, A
2004-02-01
To provide a database of the auricular measurements of Chinese infants born in Hong Kong. Prospective cross-sectional study. A total of 2384 healthy singleton, born consecutively at the Prince of Wales Hospital and the Union Hospital from October 1998 to September 2000, were included in the study. The range of gestation was 33-42 weeks. Measurements included ear width (EW), ear length (EL) and ear position (EP). The data show generally higher values for males in the parameters measured. When compared with previously published data for Caucasian and Jordanian term babies, Chinese babies have shorter EL. The ears were within normal position in nearly all our infants. The human ear appears to grow in a remarkably constant fashion. This study establishes the first set of gestational age-specific standard of the ear parameters for Chinese new-borns, potentially enabling early syndromal diagnosis. There are significant inter-racial differences in these ear parameters.
Promoting Collaborative Playful Experimentation through Group Playing by Ear in Higher Education
ERIC Educational Resources Information Center
Varvarigou, Maria
2017-01-01
A group of 46, first-year, primarily classically trained, undergraduate students took part in an exploratory research study on Group Ear Playing (GEP) in higher education. The students attended the "Playing by Ear" component of the Practical Musicianship module, which adopts the materials and strategies on playing by ear in the…
Treating "cauliflower ear" with silicone mold.
Gross, C G
1978-01-01
Acute hematoma of the ear (cauliflower ear) can be satisfactorily treated with aspiration and the use of the silicone mold to prevent reaccumulation of the blood or serum in the ear. Advantages of the silicone mold over other dressings appears to be ease of application, patient acceptance, and prevention of reoccurrence of reaccumulation of the hematoma.
15 CFR 740.18 - Agricultural commodities (AGR).
Code of Federal Regulations, 2013 CFR
2013-01-01
... EAR99. You must have an official commodity classification of EAR99 from BIS for fertilizers, western red... of the EAR). (2) No export or reexport to or for use in biological, chemical, nuclear warfare or... the EAR. If your commodity is fertilizer, western red cedar or live horses, you must confirm that BIS...
15 CFR 740.18 - Agricultural commodities (AGR).
Code of Federal Regulations, 2011 CFR
2011-01-01
... EAR99. You must have an official commodity classification of EAR99 from BIS for fertilizers, western red... of the EAR). (2) No export or reexport to or for use in biological, chemical, nuclear warfare or... the EAR. If your commodity is fertilizer, western red cedar or live horses, you must confirm that BIS...
15 CFR 740.18 - Agricultural commodities (AGR).
Code of Federal Regulations, 2010 CFR
2010-01-01
... EAR99. You must have an official commodity classification of EAR99 from BIS for fertilizers, western red... of the EAR). (2) No export or reexport to or for use in biological, chemical, nuclear warfare or... the EAR. If your commodity is fertilizer, western red cedar or live horses, you must confirm that BIS...
15 CFR 740.18 - Agricultural commodities (AGR).
Code of Federal Regulations, 2014 CFR
2014-01-01
... EAR99. You must have an official commodity classification of EAR99 from BIS for fertilizers, western red... of the EAR). (2) No export or reexport to or for use in biological, chemical, nuclear warfare or... the EAR. If your commodity is fertilizer, western red cedar or live horses, you must confirm that BIS...
15 CFR 740.18 - Agricultural commodities (AGR).
Code of Federal Regulations, 2012 CFR
2012-01-01
... EAR99. You must have an official commodity classification of EAR99 from BIS for fertilizers, western red... of the EAR). (2) No export or reexport to or for use in biological, chemical, nuclear warfare or... the EAR. If your commodity is fertilizer, western red cedar or live horses, you must confirm that BIS...
Code of Federal Regulations, 2014 CFR
2014-01-01
... Introduction. In this part, references to the EAR are references to 15 CFR chapter VII, subchapter C. (a) Scope... reexport under stated conditions, items subject to the Export Administration Regulations (EAR) that would... Supplement No. 1 to part 774 of the EAR and items subject to the EAR that would require a license based on...
Code of Federal Regulations, 2013 CFR
2013-01-01
... Introduction. In this part, references to the EAR are references to 15 CFR chapter VII, subchapter C. (a) Scope... reexport under stated conditions, items subject to the Export Administration Regulations (EAR) that would... Supplement No. 1 to part 774 of the EAR and items subject to the EAR that would require a license based on...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Introduction. In this part, references to the EAR are references to 15 CFR chapter VII, subchapter C. (a) Scope... reexport under stated conditions, items subject to the Export Administration Regulations (EAR) that would... supplement No. 1 to part 774 of the EAR and items subject to the EAR that would require a license based on...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Introduction. In this part, references to the EAR are references to 15 CFR chapter VII, subchapter C. (a) Scope... reexport under stated conditions, items subject to the Export Administration Regulations (EAR) that would... Supplement No. 1 to part 774 of the EAR and items subject to the EAR that would require a license based on...
15 CFR 740.19 - Consumer Communications Devices (CCD).
Code of Federal Regulations, 2012 CFR
2012-01-01
... EAR99 or classified under Export Control Classification Number (ECCN) 4A994.b that do not exceed an... classified under ECCN 5A992 or designated EAR99; (3) Input/output control units (other than industrial... coprocessors designated EAR99; (5) Monitors classified under ECCN 5A992 or designated EAR99; (6) Printers...
15 CFR 740.19 - Consumer Communications Devices (CCD).
Code of Federal Regulations, 2011 CFR
2011-01-01
... EAR99 or classified under Export Control Classification Number (ECCN) 4A994.b that do not exceed an... classified under ECCN 5A992 or designated EAR99; (3) Input/output control units (other than industrial... coprocessors designated EAR99; (5) Monitors classified under ECCN 5A992 or designated EAR99; (6) Printers...
15 CFR 740.19 - Consumer Communications Devices (CCD).
Code of Federal Regulations, 2014 CFR
2014-01-01
... EAR99 or classified under Export Control Classification Number (ECCN) 4A994.b that do not exceed an... classified under ECCN 5A992 or designated EAR99; (3) Input/output control units (other than industrial... coprocessors designated EAR99; (5) Monitors classified under ECCN 5A992 or designated EAR99; (6) Printers...
15 CFR 740.19 - Consumer Communications Devices (CCD).
Code of Federal Regulations, 2013 CFR
2013-01-01
... EAR99 or classified under Export Control Classification Number (ECCN) 4A994.b that do not exceed an... classified under ECCN 5A992 or designated EAR99; (3) Input/output control units (other than industrial... coprocessors designated EAR99; (5) Monitors classified under ECCN 5A992 or designated EAR99; (6) Printers...
21 CFR 874.5220 - Ear, nose, and throat drug administration device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ear, nose, and throat drug administration device. 874.5220 Section 874.5220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5220 Ear, nose...
21 CFR 874.5220 - Ear, nose, and throat drug administration device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ear, nose, and throat drug administration device. 874.5220 Section 874.5220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5220 Ear, nose...
21 CFR 874.5220 - Ear, nose, and throat drug administration device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ear, nose, and throat drug administration device. 874.5220 Section 874.5220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5220 Ear, nose...
21 CFR 874.5220 - Ear, nose, and throat drug administration device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ear, nose, and throat drug administration device. 874.5220 Section 874.5220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5220 Ear, nose...
21 CFR 874.5220 - Ear, nose, and throat drug administration device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear, nose, and throat drug administration device. 874.5220 Section 874.5220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5220 Ear, nose...
Influence of Stenocarpella maydis infected corn on the dry grind ethanol process
USDA-ARS?s Scientific Manuscript database
Widespread epidemics of Stenocarpella ear rot (formerly Diplodia ear rot) have occurred throughout the central U.S. Corn Belt in recent years with reports of some fields containing more than 50% mummified ears. Ears infected within two weeks of silking may be completely mummified with white to grayi...
Influence of Stenocarpella maydis infected corn on the dry grind ethanol process
USDA-ARS?s Scientific Manuscript database
Widespread epidemics of Stenocarpella ear rot (formerly Diplodia ear rot) have occurred throughout the central U.S. Corn Belt in recent years with reports of some fields containing more than 50% mummified ears. Ears infected within two weeks of silking may be completely mummified with white to gray...
Gfi1-Cre knock-in mouse line: A tool for inner ear hair cell-specific gene deletion
Yang, Hua; Gan, Jean; Xie, Xiaoling; Deng, Min; Feng, Liang; Chen, Xiaowei; Gao, Zhiqiang; Gan, Lin
2010-01-01
Summary Gfi1encodes a zinc-finger transcription factor essential for the development and maintenance of haematopoiesis and the inner ear. In mouse inner ear, Gfi1 expression is confined to hair cells during development and in adulthood. To construct a genetic tool for inner ear hair cell-specific gene deletion, we generated a Gfi1-Cre mouse line by knocking-in Cre coding sequences into the Gfi1 locus and inactivating the endogenous Gfi1. The specificity and efficiency of Gfi1-Cre recombinase-mediated recombination in the developing inner ear was revealed through the expression of the conditional R26R-lacZ reporter gene. The onset of lacZ expression in the Gfi1Cre/+ inner ear was first detected at E13.5 in the vestibule and at E15.5 in the cochlea, coinciding with the generation of hair cells. Throughout inner ear development, lacZ expression was detected only in hair cells. Thus, Gfi1-Cre knock-in mouse line provides a useful tool for gene manipulations specifically in inner ear hair cells. PMID:20533399
Acceleration induced water removal from ear canals.
NASA Astrophysics Data System (ADS)
Kang, Hosung; Averett, Katelee; Jung, Sunghwan
2017-11-01
Children and adults commonly experience having water trapped in the ear canals after swimming. To remove the water, individuals will shake their head sideways. Since a child's ear canal has a smaller diameter, it requires more acceleration of the head to remove the trapped water. In this study, we theoretically and experimentally investigated the acceleration required to break the surface meniscus of the water in artificial ear canals and hydrophobic-coated glass tubes. In experiments, ear canal models were 3D-printed from a CT-scanned human head. Also, glass tubes were coated with silane to match the hydrophobicity in ear canals. Then, using a linear stage, we measured the acceleration values required to forcefully eject the water from the artificial ear canals and glass tubes. A theoretical model was developed to predict the critical acceleration at a given tube diameter and water volume by using a modified Rayleigh-Taylor instability. Furthermore, this research can shed light on the potential of long-term brain injury and damage by shaking the head to push the water out of the ear canal. This research was supported by National Science Foundation Grant CBET-1604424.
Khan, Nasim Banu; Thaver, Sivashnee; Govender, Samantha Marlene
2017-12-31
Self-ear cleaning is the insertion of objects into the ear canal to clean it, a widespread practice that has the potential to compromise its integrity as a natural, selfcleansing mechanism, and a risk factor for possible injuries. The practice is common among young adults and highest in university than any other graduates. This study aimed to determine the self-ear cleaning practices and associated risk of injury and related symptoms in undergraduate students at KwaZulu-Natal University. The descriptive survey utilized a self-administered questionnaire. Of the 206 participants that responded, 98% engaged in self-ear cleaning, with 75% indicating that it was beneficial. The commonest method (79.6%) being the use of cotton buds, with an associated injury rate of 2.4%. There was no statistically significant associations between those who used or did not use cotton buds and the symptoms experienced. The complications indicate that self-ear cleaning does pose a risk for injury, necessitating more community information and education.
Factors that introduce intrasubject variability into ear-canal absorbance measurements.
Voss, Susan E; Stenfelt, Stefan; Neely, Stephen T; Rosowski, John J
2013-07-01
Wideband immittance measures can be useful in analyzing acoustic sound flow through the ear and also have diagnostic potential for the identification of conductive hearing loss as well as causes of conductive hearing loss. To interpret individual measurements, the variability in test–retest data must be described and quantified. Contributors to variability in ear-canal absorbance–based measurements are described in this article. These include assumptions related to methodologies and issues related to the probe fit within the ear and potential acoustic leaks. Evidence suggests that variations in ear-canal cross-sectional area or measurement location are small relative to variability within a population. Data are shown to suggest that the determination of the Thévenin equivalent of the ER-10C probe introduces minimal variability and is independent of the foam ear tip itself. It is suggested that acoustic leaks in the coupling of the ear tip to the ear canal lead to substantial variations and that this issue needs further work in terms of potential criteria to identify an acoustic leak. In addition, test–retest data from the literature are reviewed.
Inverse solution of ear-canal area function from reflectance
Rasetshwane, Daniel M.; Neely, Stephen T.
2011-01-01
A number of acoustical applications require the transformation of acoustical quantities, such as impedance and pressure that are measured at the entrance of the ear canal, to quantities at the eardrum. This transformation often requires knowledge of the shape of the ear canal. Previous attempts to measure ear-canal area functions were either invasive, non-reproducible, or could only measure the area function up to a point mid-way along the canal. A method to determine the area function of the ear canal from measurements of acoustic impedance at the entrance of the ear canal is described. The method is based on a solution to the inverse problem in which measurements of impedance are used to calculate reflectance, which is then used to determine the area function of the canal. The mean ear-canal area function determined using this method is similar to mean ear-canal area functions measured by other researchers using different techniques. The advantage of the proposed method over previous methods is that it is non- invasive, fast, and reproducible. PMID:22225043
NASA Astrophysics Data System (ADS)
Liao, Lu-hai; Zheng, Xiao-fei; Kang, Yong-lin; Liu, Wei; Yan, Yan; Mo, Zhi-ying
2018-06-01
Since the production of tinplate with non-earing properties is difficult, especially when it is produced via the double-reduction process, the optimal degree of second cold reduction is particularly important for achieving desirable drawing properties. The evolution of texture and the earing propensity of double-reduction tinplate with different extents of second reduction were investigated in this study. Optical microscopy and scanning electron microscopy were used to observe the changes in the microstructure at various extents of reduction. Two common testing methods, X-ray diffraction (XRD) and electron backscatter diffraction, were used to investigate the texture of the specimens, which revealed the effects of deformation percentage on the final texture development and the change in the grain boundary. The earing rate was determined via earing tests involving measurement of the height of any ear. The results obtained from both XRD analyses and earing tests revealed the same ideal value for the second cold reduction on the basis of the relationship between crystallographic texture and the degree of earing.
Leupeptin reduces impulse noise induced hearing loss
2011-01-01
Background Exposure to continuous and impulse noise can induce a hearing loss. Leupeptin is an inhibitor of the calpains, a family of calcium-activated proteases which promote cell death. The objective of this study is to assess whether Leupeptin could reduce the hearing loss resulting from rifle impulse noise. Methods A polyethelene tube was implanted into middle ear cavities of eight fat sand rats (16 ears). Following determination of auditory nerve brainstem evoked response (ABR) threshold in each ear, the animals were exposed to the noise of 10 M16 rifle shots. Immediately after the exposure, saline was then applied to one (control) ear and non-toxic concentrations of leupeptin determined in the first phase of the study were applied to the other ear, for four consecutive days. Results Eight days after the exposure, the threshold shift (ABR) in the control ears was significantly greater (44 dB) than in the leupeptin ears (27 dB). Conclusion Leupeptin applied to the middle ear cavity can reduce the hearing loss resulting from exposure to impulse noise. PMID:22206578
Current Status and Prospects of Gene Therapy for the Inner Ear
Huang, Aji
2011-01-01
Abstract Inner ear diseases are common and often result in hearing disability. Sensorineural hearing loss is the main cause of hearing disability. So far, no effective treatment is available although some patients may benefit from a hearing aid equipped with a hearing amplifier or from cochlear implantation. Inner ear gene therapy has become an emerging field of study for the treatment of hearing disability. Numerous new discoveries and tremendous advances have been made in inner ear gene therapy including gene vectors, routes of administration, and therapeutic genes and targets. Gene therapy may become a treatment option for inner ear diseases in the near future. In this review, we summarize the current state of inner ear gene therapy including gene vectors, delivery routes, and therapeutic genes and targets by examining and analyzing publications on inner ear gene therapy from the literature and patent documents, and identify promising patents, novel techniques, and vital research projects. We also discuss the progress and prospects of inner ear gene therapy, the advances and shortcomings, with possible solutions in this field of research. PMID:21338273
The ideal ear position in Caucasian females.
Broer, P Niclas; Thiha, Aung; Ehrl, Denis; Sinno, Sammy; Juran, Sabrina; Szpalski, Caroline; Ng, Reuben; Ninkovic, Milomir; Prantl, Lukas; Heidekrueger, Paul I
2018-03-01
Ear position contributes significantly to facial appearance. However, while objective measurements remain the foundation for esthetic evaluations, little is known about how an ear should ideally be positioned regarding its rotational axis. This study aimed to further evaluate whether there exists a universally applicable ideal ear axis, and how sociodemographic factors impact such preferences. An interactive online survey was designed, enabling participants to change the axis of a female model's ear in terms of its forward and backward rotation. The questionnaire was sent out internationally to plastic surgeons and the general public. Demographic data were collected and analysis of variance was used to investigate respective preferences. A total of 1016 responses from 35 different countries (response rate: 18.5%) were gathered. Overall, 60% of survey takers chose the minus 10 or 5° angles to be most attractive. Significant differences were found regarding sex, ethnicity, country of residence, profession and respective ear axis preferences. Across multiple countries and ethnicities, an ear position in slight reclination of minus 5-10° is considered most pleasing in Caucasian females. However, sociodemographic factors significantly impact individual ear axis preferences and should be taken into consideration when performing reconstructive ear surgery. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Finite element modeling of acousto-mechanical coupling in the cat middle ear
Tuck-Lee, James P.; Pinsky, Peter M.; Steele, Charles R.; Puria, Sunil
2008-01-01
The function of the middle ear is to transfer acoustic energy from the ear canal to the cochlea. An essential component of this system is the tympanic membrane. In this paper, a new finite element model of the middle ear of the domestic cat is presented, generated in part from cadaver anatomy via microcomputed tomographic imaging. This model includes a layered composite model of the eardrum, fully coupled with the acoustics in the ear canal and middle-ear cavities. Obtaining the frequency response from 100 Hz to 20 kHz is a computationally challenging task, which has been accomplished by using a new adaptive implementation of the reduced-order matrix Padé-via-Lanczos algorithm. The results are compared to established physiological data. The fully coupled model is applied to study the role of the collagen fiber sublayers of the eardrum and to investigate the relationship between the structure of the middle-ear cavities and its function. Three applications of this model are presented, demonstrating the shift in the middle-ear resonance due to the presence of the septum that divides the middle-ear cavity space, the significance of the radial fiber layer on high frequency transmission, and the importance of the transverse shear modulus in the eardrum microstructure. PMID:18646982
Short, Kirsty R.; von Köckritz-Blickwede, Maren; Langereis, Jeroen D.; Chew, Keng Yih; Job, Emma R.; Armitage, Charles W.; Hatcher, Brandon; Fujihashi, Kohtaro; Reading, Patrick C.; Hermans, Peter W.
2014-01-01
Otitis media (OM) (a middle ear infection) is a common childhood illness that can leave some children with permanent hearing loss. OM can arise following infection with a variety of different pathogens, including a coinfection with influenza A virus (IAV) and Streptococcus pneumoniae (the pneumococcus). We and others have demonstrated that coinfection with IAV facilitates the replication of pneumococci in the middle ear. Specifically, we used a mouse model of OM to show that IAV facilitates the outgrowth of S. pneumoniae in the middle ear by inducing middle ear inflammation. Here, we seek to understand how the host inflammatory response facilitates bacterial outgrowth in the middle ear. Using B cell-deficient infant mice, we show that antibodies play a crucial role in facilitating pneumococcal replication. We subsequently show that this is due to antibody-dependent neutrophil extracellular trap (NET) formation in the middle ear, which, instead of clearing the infection, allows the bacteria to replicate. We further demonstrate the importance of these NETs as a potential therapeutic target through the transtympanic administration of a DNase, which effectively reduces the bacterial load in the middle ear. Taken together, these data provide novel insight into how pneumococci are able to replicate in the middle ear cavity and induce disease. PMID:24191297
NASA Astrophysics Data System (ADS)
Johansson, L. Christoffer; Håkansson, Jonas; Jakobsen, Lasse; Hedenström, Anders
2016-04-01
Large ears enhance perception of echolocation and prey generated sounds in bats. However, external ears likely impair aerodynamic performance of bats compared to birds. But large ears may generate lift on their own, mitigating the negative effects. We studied flying brown long-eared bats, using high resolution, time resolved particle image velocimetry, to determine the aerodynamics of flying with large ears. We show that the ears and body generate lift at medium to cruising speeds (3-5 m/s), but at the cost of an interaction with the wing root vortices, likely reducing inner wing performance. We also propose that the bats use a novel wing pitch mechanism at the end of the upstroke generating thrust at low speeds, which should provide effective pitch and yaw control. In addition, the wing tip vortices show a distinct spiraling pattern. The tip vortex of the previous wingbeat remains into the next wingbeat and rotates together with a newly formed tip vortex. Several smaller vortices, related to changes in circulation around the wing also spiral the tip vortex. Our results thus show a new level of complexity in bat wakes and suggest large eared bats are less aerodynamically limited than previous wake studies have suggested.
Ultrasound characterization of middle ear effusion.
Seth, Rahul; Discolo, Christopher M; Palczewska, Grazyna M; Lewandowski, Jan J; Krakovitz, Paul R
2013-01-01
To further enhance and assess the ability to characterize middle ear effusion (MEE) using non-invasive ultrasound technology. This is a prospective unblinded comparison study. Fifty-six children between the ages of 6 months and 17 years scheduled to undergo bilateral myringotomy with pressure equalization tube placement were enrolled. With the child anesthetized, the probe was placed into the external ear canal after sterile water was inserted. Ultrasound recordings of middle ear contents were analyzed by computer algorithm. Middle ear fluid was collected during myringotomy and analyzed for bacterial culture and viscosity. Ultrasound waveforms yielded a computer algorithm interpretation of middle ear contents in 66% of ears tested. When a result was obtained, the sensitivity and specificity for successfully characterizing middle ear fluid content as either void of fluid, thick fluid (mucoid), or thin fluid (serous or purulent) were at least 94%. Mucoid effusions had higher measured viscosity values (P=.002). Viscosity measures were compared to culture result, and those with low viscosity (thin consistency) had a higher likelihood of having a positive culture (P=.048). The device sensitivity and specificity for fluid detection were 94% or greater among interpretable waveforms (66% of those tested). Although this technology provides important information of the middle ear effusion presence and characteristic, further technological improvements are needed. Copyright © 2013 Elsevier Inc. All rights reserved.
Human middle-ear model with compound eardrum and airway branching in mastoid air cells
Keefe, Douglas H.
2015-01-01
An acoustical/mechanical model of normal adult human middle-ear function is described for forward and reverse transmission. The eardrum model included one component bound along the manubrium and another bound by the tympanic cleft. Eardrum components were coupled by a time-delayed impedance. The acoustics of the middle-ear cleft was represented by an acoustical transmission-line model for the tympanic cavity, aditus, antrum, and mastoid air cell system with variable amounts of excess viscothermal loss. Model parameters were fitted to published measurements of energy reflectance (0.25–13 kHz), equivalent input impedance at the eardrum (0.25–11 kHz), temporal-bone pressure in scala vestibuli and scala tympani (0.1–11 kHz), and reverse middle-ear impedance (0.25–8 kHz). Inner-ear fluid motion included cochlear and physiological third-window pathways. The two-component eardrum with time delay helped fit intracochlear pressure responses. A multi-modal representation of the eardrum and high-frequency modeling of the middle-ear cleft helped fit ear-canal responses. Input reactance at the eardrum was small at high frequencies due to multiple modal resonances. The model predicted the middle-ear efficiency between ear canal and cochlea, and the cochlear pressures at threshold. PMID:25994701
Human middle-ear model with compound eardrum and airway branching in mastoid air cells.
Keefe, Douglas H
2015-05-01
An acoustical/mechanical model of normal adult human middle-ear function is described for forward and reverse transmission. The eardrum model included one component bound along the manubrium and another bound by the tympanic cleft. Eardrum components were coupled by a time-delayed impedance. The acoustics of the middle-ear cleft was represented by an acoustical transmission-line model for the tympanic cavity, aditus, antrum, and mastoid air cell system with variable amounts of excess viscothermal loss. Model parameters were fitted to published measurements of energy reflectance (0.25-13 kHz), equivalent input impedance at the eardrum (0.25-11 kHz), temporal-bone pressure in scala vestibuli and scala tympani (0.1-11 kHz), and reverse middle-ear impedance (0.25-8 kHz). Inner-ear fluid motion included cochlear and physiological third-window pathways. The two-component eardrum with time delay helped fit intracochlear pressure responses. A multi-modal representation of the eardrum and high-frequency modeling of the middle-ear cleft helped fit ear-canal responses. Input reactance at the eardrum was small at high frequencies due to multiple modal resonances. The model predicted the middle-ear efficiency between ear canal and cochlea, and the cochlear pressures at threshold.
Morphometry of the ear in Down's syndrome subjects. A three-dimensional computerized assessment.
Sforza, C; Dellavia, C; Tartaglia, G M; Ferrario, V F
2005-07-01
The three-dimensional coordinates of 13 soft-tissue landmarks on the ears were obtained by a computerized digitizer in 28 subjects with Down's syndrome aged 12-45 years, and in 449 sex, age and ethnic group matched controls. From the landmarks, left and right linear distances (ear width and length), ratios (ear width-to-ear length), areas (ear area), angles (angle of the auricle versus the facial midplane) and the three-dimensional symmetry index were calculated. For both males and females, all linear dimensions and areas were significantly (Analysis of Variance, P < 0.001) larger in the reference subjects than in the subjects with Down's syndrome. All values significantly increased as a function of age (P < 0.05); the increment was larger in the reference subjects than in the subjects with Down's syndrome. On both sides of the face, the subjects with Down's syndrome had larger ear width-to-ear length ratios, and larger angles of the auricle versus the facial midplane than the reference subjects. The three-dimensional symmetry index was significantly larger in the reference subjects and in the older persons. In conclusion, ear dimensions, position and shape significantly differed in subjects with Down's syndrome when compared to sex, age and ethnic group matched controls. Some of the differences were sex and age related.
Ultrasound Characterization of Middle Ear Effusion
Seth, Rahul; Discolo, Christopher M; Palczewska, Grazyna M; Lewandowski, Jan J; Krakovitz, Paul R
2012-01-01
Purpose To further enhance and assess the ability to characterize middle ear effusion (MEE) using non-invasive ultrasound technology. Materials and Methods This is a prospective unblinded comparison study. Fifty-six children between the ages of 6 months and 17 years scheduled to undergo bilateral myringotomy with pressure equalization tube placement were enrolled. With the child anesthetized, the probe was placed into the external ear canal after sterile water was inserted. Ultrasound recordings of middle ear contents were analyzed by computer algorithm. Middle ear fluid was collected during myringotomy and analyzed for bacterial culture and viscosity. Results Ultrasound waveforms yielded a computer algorithm interpretation of middle ear contents in 66% of ears tested. When a result was obtained, the sensitivity and specificity for successfully characterizing middle ear fluid content as either void of fluid, thick fluid (mucoid), or thin fluid (serous or purulent) was at least 94%. Mucoid effusions had higher measured viscosity values (P=0.002). Viscosity measures were compared to culture result, and those with low viscosity (thin consistency) had a higher likelihood of having a positive culture (P=0.048). Conclusion The device sensitivity and specificity for fluid detection was 94% or greater among interpretable waveforms (66% of those tested). Although this technology provides important information of the middle ear effusion presence and characteristic, further technological improvements are needed. PMID:23084430
The influence of target-masker similarity on across-ear interference in dichotic listening
NASA Astrophysics Data System (ADS)
Brungart, Douglas; Simpson, Brian
2004-05-01
In most dichotic listening tasks, the comprehension of a target speech signal presented in one ear is unaffected by the presence of irrelevant speech in the opposite ear. However, recent results have shown that contralaterally presented interfering speech signals do influence performance when a second interfering speech signal is present in the same ear as the target speech. In this experiment, we examined the influence of target-masker similarity on this effect by presenting ipsilateral and contralateral masking phrases spoken by the same talker, a different same-sex talker, or a different-sex talker than the one used to generate the target speech. The results show that contralateral target-masker similarity has the greatest influence on performance when an easily segregated different-sex masker is presented in the target ear, and the least influence when a difficult-to-segregate same-talker masker is presented in the target ear. These results indicate that across-ear interference in dichotic listening is not directly related to the difficulty of the segregation task in the target ear, and suggest that contralateral maskers are least likely to interfere with dichotic speech perception when the same general strategy could be used to segregate the target from the masking voices in the ipsilateral and contralateral ears.
Aetiological agents of ear discharge: a two year review in a teaching hospital in Ghana.
Appiah-Korang, L; Asare-Gyasi, S; Yawson, A E; Searyoh, K
2014-06-01
The discharging ear is a common presentation in medical practice affecting all age groups but primarily children. This study shows the current aetiological causes of ear discharge and their antibiograms, data which would guide empirical treatment of ear infections, and also form a basis for further research. This was a retrospective review of laboratory records of all ear swabs submitted for culture over a two year period in the Korle Bu Teaching Hospital Accra, Ghana. Data was obtained on demographic characteristics of patients, clinical diagnosis, isolated organisms and antibiotic susceptibility patterns of the isolated organisms. Data was analyzed by simple descriptive statistics. A total of 351 ear swabs were received by the laboratory for processing over the two year period. Of these 277(78.9%) had microorganisms isolated. A significant number127 (47%) was obtained from children under five years. Pseudomonas spp was the commonly isolated organism 121(46%) followed by Staphylococcus aureus 33(12.5%) and Proteus spp 32(12.2%). Candida was the commonest isolated fungi 9 (69.2%). Susceptibility of Pseudomonas spp to commonly used ototopics (ciprofloxacin & gentamicin) was 93% and 74% respectively. Most cases of the discharging ear were found in children under the age of five years. The most common bacteriologic cause of the discharging ear was Pseudomonas spp followed by Staphylococcus aureus. Candida species was the commonest fungal cause of ear discharge. Ciprofloxacin and gentamicin are effective ototopic antimicrobial agents for empirical treatment of the discharging ear.
The effect of stimulus intensity on the right ear advantage in dichotic listening.
Hugdahl, Kenneth; Westerhausen, René; Alho, Kimmo; Medvedev, Svyatoslav; Hämäläinen, Heikki
2008-01-24
The dichotic listening test is non-invasive behavioural technique to study brain lateralization and it has been shown, that its results can be systematically modulated by varying stimulation properties (bottom-up effects) or attentional instructions (top-down effects) of the testing procedure. The goal of the present study was to further investigate the bottom-up modulation, by examining the effect of differences in the right or left ear stimulus intensity on the ear advantage. For this purpose, interaural intensity difference were gradually varied in steps of 3 dB from -21 dB in favour of the left ear to +21 dB in favour of the right ear, also including a no difference baseline condition. Thirty-three right-handed adult participants with normal hearing acuity were tested. The dichotic listening paradigm was based on consonant-vowel stimuli pairs. Only pairs with the same voicing (voice or non-voiced) of the consonant sound were used. The results showed: (a) a significant right ear advantage (REA) for interaural intensity differences from 21 to -3 dB, (b) no ear advantage (NEA) for the -6 dB difference, and (c) a significant left ear advantage (LEA) for differences form -9 to -21 dB. It is concluded that the right ear advantage in dichotic listening to CV syllables withstands an interaural intensity difference of -9 dB before yielding to a significant left ear advantage. This finding could have implications for theories of auditory laterality and hemispheric asymmetry for phonological processing.
Denervation affects regenerative responses in MRL/MpJ and repair in C57BL/6 ear wounds
Buckley, Gemma; Wong, Jason; Metcalfe, Anthony D; Ferguson, Mark W J
2012-01-01
The MRL/MpJ mouse displays the rare ability amongst mammals to heal injured ear tissue without scarring. Numerous studies have shown that the formation of a blastema-like structure leads to subsequent tissue regeneration in this model, indicating many parallels with amphibian limb regeneration and mammalian embryogenesis. We have recently shown that the MRL/MpJ mouse also possesses an enhanced capacity for peripheral nerve regeneration within the ear wound. Indeed, nerves are vital for the initial phase of blastema formation in the amphibian limb. In this study we investigated the capacity for wound regeneration in a denervated ear. The left ears of MRL/MpJ mice and C57BL/6 (a control strain known to have a poorer regenerative capacity) were surgically denervated at the base via an incision and nerve transection, immediately followed by a 2-mm ear punch wound. Immunohistochemical analysis showed a lack of neurofilament expression in the denervated ear wound. Histology revealed that denervation prevented blastema formation and chrondrogenesis, and also severely hindered normal healing, with disrupted re-epithelialisation, increasing wound size and progressive necrosis towards the ear tip. Denervation of the ear obliterated the regenerative capacity of the MRL/MpJ mouse, and also had a severe negative effect on the ear wound repair mechanisms of the C57BL/6 strain. These data suggest that innervation may be important not only for regeneration but also for normal wound repair processes. PMID:22066944
Inner ear dysplasia is common in children with Down syndrome (trisomy 21).
Blaser, Susan; Propst, Evan J; Martin, Daniel; Feigenbaum, Annette; James, Adrian L; Shannon, Patrick; Papsin, Blake C
2006-12-01
Middle and external ear anomalies are well recognized in Down syndrome (DS, trisomy 21). Inner ear anomalies are much less frequently described. This study reviews inner ear morphology on imaging to determine the prevalence of cochlear and vestibular anomalies in children with DS. The authors conducted a retrospective review of imaging features of (DS) inner ear structures. Fifty-nine sequential patients with DS with imaging of the inner ear were identified by a radiology report text search program. Quantitative biometric assessment of the inner ear was performed on patients with high-resolution computed tomography or magnetic resonance images of the petrous bone. Petrous imaging was performed for evaluation of inflammatory disease or hearing loss. Spinal imaging, which included petrous views, was performed in most cases to exclude C1 to 2 dislocation, a potential complication of DS. Measurements were compared with normative data. Inner ear dysplasia is much more common in DS than previously reported. Inner ear structures are universally hypoplastic. Vestibular malformations are particularly common and a small bony island of the lateral semicircular canal (<3 mm in diameter) appears highly typical. Additional findings in some patients were persistent lateral semicircular anlage with fusion of the lateral semicircular canal and vestibule into a single cavity, vestibular aqueduct and endolymphatic sac fossa enlargement, cochlear nerve canal hypoplasia, and stenosis or duplication of the internal auditory canal. Stenosis of the external meatus, poor mastoid pneumatization, middle ear and mastoid opacification, and cholesteatoma were common, as expected.
CT of the ear in Pendred syndrome.
Goldfeld, Moshe; Glaser, Benjamin; Nassir, Elias; Gomori, John Moshe; Hazani, Elitsur; Bishara, Nassir
2005-05-01
To prospectively determine the structural anomalies of the inner ear by using thin-section computed tomography (CT) in an extended family with Pendred syndrome. Ethics committee approved the study, and informed consent was obtained from every patient or from parents of patients under legal age. Twelve patients (three females and nine males aged 7-47 years) with Pendred syndrome (all from the same ethnic isolate and with the same mutation in the PDS gene) were evaluated for inner-ear malformation at thin-section CT. Both ears were evaluated. Presence or absence of interscalar septum between upper and middle turns of the cochlea was evaluated, and vestibule and vestibular aqueduct were examined for enlargement. Modiolus was determined to be present or absent (modiolar deficiency). CT scans were evaluated in consensus by two radiologists (M.G., J.M.G.). All patients had inner ear malformation on both sides. Modiolus was absent and vestibule was enlarged on both sides in all 12 patients. Interscalar septum was absent in 18 (75%) of 24 ears. In eight patients, interscalar septum was absent in both ears, whereas in two patients, it was absent on only one side. Aqueduct was enlarged in 20 (80%) of 24 ears. In nine patients, both ears had enlarged aqueducts, while in two patients, only one side was abnormal. Inner ear malformation is an invariable finding in Pendred syndrome. Modiolus deficiency and vestibular enlargement were the most consistent anomalies in this population with Pendred syndrome. (c) RSNA, 2005.
Examination of the pest status of corn-infesting Ulidiidae (Diptera).
Goyal, Gaurav; Nuessly, Gregg S; Seal, Dakshina R; Steck, Gary J; Capinera, John L; Meagher, Robert L
2012-10-01
Larvae of 11 species of picture-winged flies (Diptera: Ulididae) are known to feed on corn plants (Zea mays L.) in the western hemisphere. Larvae emerge from eggs deposited in leaf axils and corn silk to feed mostly within ears, but the primary versus secondary nature (i.e., pest status) of their infestation is not known for all of these species. Choice and no-choice tests by using a split-plot design were conducted in greenhouse and field trials to determine the pest status on sweet corn of three of these species found in Florida: Chaetopsis massyla (Walker), Euxesta eluta Loew, and E. stigmatias Loew. The main treatments (uninfested ears and ears experimentally infested with either Spodoptera frugiperda [Lepidoptera: Noctuidae] or E. eluta larvae) were applied at first silk. The subtreatments (C. massyla, E. eluta, or E. stigmatias adults caged on ears) were applied 7 d later and maintained for 10 d. All three fly species were reared from uninfested and experimentally infested ears in both choice and no-choice tests in greenhouse and field trials confirming both primary and secondary modes of ear infestation. More flies of all three species emerged from ears that were preinfested with S. frugiperda compared with uninfested ears suggesting either preference for or greater survival within ears previously infested by S. frugiperda. Fewer E. eluta and E. stigmatias emerged from ears preinfested with E. eluta in no-choice field tests, suggesting that previous infestation by this fly may negatively affect oviposition or that older fly larvae affect survival of neonate larvae. All three species studied here should be considered primary pests that can render unprotected sweet corn ears unmarketable.
Xiong, Wu; Yan, Yu; Hu, Feng; Liu, Can; Wang, Shaohua; Chen, Jia; Wang, Xueqi; Zhou, Jianda
2016-01-01
Ear reconstruction is one of the most complicated and challenging techniques in plastic surgery because of the histologic and anatomic properties of the ear. Success depends on fitting the auriform cartilage scaffold into the overlying skin, but current approaches can just give results that are not lifelike and can lead to complications. A novel double-capsule, double-valve plastic ear expander was designed and implanted subcutaneously on either side of the dorsum of six New Zealand white rabbits (two expanders per rabbit). The outer capsule was expanded by injecting approximately 120 mL of physiological saline, then withdrawing the liquid on two occasions. Next, the ear-shaped inner capsule was filled with high-hardness plaster, and the external capsule was emptied such that the expanded skin flap and external capsule responded to the negative pressure and closed over the ear-shaped inner capsule. As a result, the skin flap adopted an ear shape. The ear expander was left in place for 4 wk, removed with the help of a mini-incision, and stripped of its fibrous capsule. To simulate human ear reconstruction, the expander was replaced with an auriform silicone prosthesis, and the effects of auricular reconstruction were observed dynamically. All 12 skin flaps maintained abundant blood supply, created a clear outline of the ear framework, and produced a lifelike result. No complications were observed during the 4-wk observation period. The expanded skin flaps described here can mold to the desired contours and appear lifelike, as well as maintain abundant blood supply. This may provide a simpler approach to total ear reconstruction that reduces risk of complications. Copyright © 2016 Elsevier Inc. All rights reserved.
Pinnaplasty: reshaping ears to improve hearing aid retention.
Gault, David; Grob, Marion; Odili, Joy
2007-01-01
The hearing aid is extremely important to the deaf. A small number have difficulty in retaining the device because the ear is prominent or cup-shaped. This report describes 11 children whose ear shape was modified to improve hearing aid retention and one adult in whom an over set back ear was released to allow fitment of a postaural device. In eight of the 11 children treated, conservative measures such as double-sided tape and retention bands (Huggies) had been tried previously without success. The creation of an antihelical fold in a misshapen ear lacking such a fold provides a reinforcing strut which is useful to support a hearing aid. In patients whose ear had been excessively tethered by previous surgery, projection was restored by inserting a cartilage block behind the ear. In one child with ears tethered by previous surgery, costal cartilage was used not only to release both ears, but also to reconstruct a new helical rim on one side. Surgery enabled a normal postaural hearing aid to be worn in 17 of the 19 ears treated. The two failures deserve special mention. In one patient with a unilateral deformity and severe mental retardation, the dressings were pulled off immediately after surgery. In another patient with a bilateral problem, the appearance and hearing aid retention was improved, but there was not enough room in the postauricular sulcus on one side for the battery component to fit comfortably and an in-the-ear device is now used on that side. Pinnaplasty is a helpful strategy to improve hearing aid retention. Care must be taken not to overdo the set back so that enough room is left to retain the hearing device.
Benefits of active middle ear implants in mixed hearing loss: Stapes versus round window.
Lee, Jeon Mi; Jung, Jinsei; Moon, In Seok; Kim, Sung Huhn; Choi, Jae Young
2017-06-01
We compared the audiologic benefits of active middle ear implants with those of passive middle ear implants with hearing aids in mixed hearing loss, and also compared the outcomes of stapes vibroplasty with those of round window vibroplasty. Retrospective chart review. Thirty-four patients with mixed hearing loss due to chronic otitis media were treated with a middle ear implant. Of these, 15 were treated with a passive middle ear implant (conventional ossiculoplasty with a partial ossicular replacement prosthesis), nine with an active middle ear implant coupling to the stapes, and 10 with an active middle ear implant coupling to the round window. Patients underwent pure-tone/free-field audiograms and speech discrimination tests before surgery and 6 months after surgery, and the results of these tests were compared. The active middle ear implant resulted in better outcomes than the passive middle ear implant with hearing aids at mid to high frequencies (P < .05). Patients who received either a stapes vibroplasty or a round window vibroplasty showed comparable hearing gain except at 8,000 Hz (48.9 dB vs. 31.0 dB, P < .05). Patients who received a stapes vibroplasty showed an improvement even in bone conduction at 1,000 Hz and 2,000 Hz (both P < .05). Active middle ear implantation could be a better option than treatment with passive middle ear implants with hearing aids for achieving rehabilitation in patients with mixed hearing loss. Vibroplasty via either oval window or round window stimulation shares similar good results. 4 Laryngoscope, 127:1435-1441, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
[Facial nerve monitoring during middle ear surgery: Results of a French survey].
Mazzaschi, O; Juvanon, J-M; Mondain, M; Lavieile, J-P; Ayache, D
2014-01-01
Facial nerve injury is a rare complication of middle ear surgery. To date there is no widely accepted consensus on the use of intraoperative facial nerve monitoring during middle ear surgery, whereas its use has been proved as a valuable adjunct in neurotologic surgery. The purpose of our study was to identify introperative facial nerve monitoring practice patterns in France for middle ear surgery. A 19-item survey has been made up by three experienced otologists under the auspices of the French Otology and Neurotology Association. With the support of the French Society of Otolaryngology--Head and Neck Surgery, the survey was electronically sent by email to 1249 practicing ENT with a valid email address. Answers were analyzed two months later. Among 1249 email sent, 299 were opened (24%) and 83 answers were collected (6,6%). Of the respondents, 66% had access to intraoperative facial nerve monitoring. Otolaryngologists involved in academic setting were influenced by their teaching duty in 27%. Intraoperative facial nerve monitoring should not be required for stapes surgery, ossiculoplasty, myringoplasty for, respectively, 92%, 93 % and 98% of the respondents. In cochlear implantation, 78% of ear surgeons used facial nerve monitoring. Answers were more controversial for chronic ear surgery, ear atresia and middle ear implant. Revision surgery and CT scan can influence answers. Despite a low response rate, results of this national survey revealed interesting findings. For most of the respondents, intraoperative facial nerve monitoring was not indicated in stapes surgery, myringoplasty and ossiculoplasty. The use of intraoperative facial nerve monitoring for cochlear implantation was supported by the majority of respondents. Variations in response rate were more significant for chronic ear surgery, including middle ear cholesteatoma, and for ear atresia surgery.
Physiological artifacts in scalp EEG and ear-EEG.
Kappel, Simon L; Looney, David; Mandic, Danilo P; Kidmose, Preben
2017-08-11
A problem inherent to recording EEG is the interference arising from noise and artifacts. While in a laboratory environment, artifacts and interference can, to a large extent, be avoided or controlled, in real-life scenarios this is a challenge. Ear-EEG is a concept where EEG is acquired from electrodes in the ear. We present a characterization of physiological artifacts generated in a controlled environment for nine subjects. The influence of the artifacts was quantified in terms of the signal-to-noise ratio (SNR) deterioration of the auditory steady-state response. Alpha band modulation was also studied in an open/closed eyes paradigm. Artifacts related to jaw muscle contractions were present all over the scalp and in the ear, with the highest SNR deteriorations in the gamma band. The SNR deterioration for jaw artifacts were in general higher in the ear compared to the scalp. Whereas eye-blinking did not influence the SNR in the ear, it was significant for all groups of scalps electrodes in the delta and theta bands. Eye movements resulted in statistical significant SNR deterioration in both frontal, temporal and ear electrodes. Recordings of alpha band modulation showed increased power and coherence of the EEG for ear and scalp electrodes in the closed-eyes periods. Ear-EEG is a method developed for unobtrusive and discreet recording over long periods of time and in real-life environments. This study investigated the influence of the most important types of physiological artifacts, and demonstrated that spontaneous activity, in terms of alpha band oscillations, could be recorded from the ear-EEG platform. In its present form ear-EEG was more prone to jaw related artifacts and less prone to eye-blinking artifacts compared to state-of-the-art scalp based systems.
Luštrek, Mitja; Lorenz, Peter; Kreutzer, Michael; Qian, Zilliang; Steinbeck, Felix; Wu, Di; Born, Nadine; Ziems, Bjoern; Hecker, Michael; Blank, Miri; Shoenfeld, Yehuda; Cao, Zhiwei; Glocker, Michael O; Li, Yixue; Fuellen, Georg; Thiesen, Hans-Jürgen
2013-01-01
Epitope-antibody-reactivities (EAR) of intravenous immunoglobulins (IVIGs) determined for 75,534 peptides by microarray analysis demonstrate that roughly 9% of peptides derived from 870 different human protein sequences react with antibodies present in IVIG. Computational prediction of linear B cell epitopes was conducted using machine learning with an ensemble of classifiers in combination with position weight matrix (PWM) analysis. Machine learning slightly outperformed PWM with area under the curve (AUC) of 0.884 vs. 0.849. Two different types of epitope-antibody recognition-modes (Type I EAR and Type II EAR) were found. Peptides of Type I EAR are high in tyrosine, tryptophan and phenylalanine, and low in asparagine, glutamine and glutamic acid residues, whereas for peptides of Type II EAR it is the other way around. Representative crystal structures present in the Protein Data Bank (PDB) of Type I EAR are PDB 1TZI and PDB 2DD8, while PDB 2FD6 and 2J4W are typical for Type II EAR. Type I EAR peptides share predicted propensities for being presented by MHC class I and class II complexes. The latter interaction possibly favors T cell-dependent antibody responses including IgG class switching. Peptides of Type II EAR are predicted not to be preferentially presented by MHC complexes, thus implying the involvement of T cell-independent IgG class switch mechanisms. The high extent of IgG immunoglobulin reactivity with human peptides implies that circulating IgG molecules are prone to bind to human protein/peptide structures under non-pathological, non-inflammatory conditions. A webserver for predicting EAR of peptide sequences is available at www.sysmed-immun.eu/EAR.
QTL Mapping of Kernel Number-Related Traits and Validation of One Major QTL for Ear Length in Maize.
Huo, Dongao; Ning, Qiang; Shen, Xiaomeng; Liu, Lei; Zhang, Zuxin
2016-01-01
The kernel number is a grain yield component and an important maize breeding goal. Ear length, kernel number per row and ear row number are highly correlated with the kernel number per ear, which eventually determines the ear weight and grain yield. In this study, two sets of F2:3 families developed from two bi-parental crosses sharing one inbred line were used to identify quantitative trait loci (QTL) for four kernel number-related traits: ear length, kernel number per row, ear row number and ear weight. A total of 39 QTLs for the four traits were identified in the two populations. The phenotypic variance explained by a single QTL ranged from 0.4% to 29.5%. Additionally, 14 overlapping QTLs formed 5 QTL clusters on chromosomes 1, 4, 5, 7, and 10. Intriguingly, six QTLs for ear length and kernel number per row overlapped in a region on chromosome 1. This region was designated qEL1.10 and was validated as being simultaneously responsible for ear length, kernel number per row and ear weight in a near isogenic line-derived population, suggesting that qEL1.10 was a pleiotropic QTL with large effects. Furthermore, the performance of hybrids generated by crossing 6 elite inbred lines with two near isogenic lines at qEL1.10 showed the breeding value of qEL1.10 for the improvement of the kernel number and grain yield of maize hybrids. This study provides a basis for further fine mapping, molecular marker-aided breeding and functional studies of kernel number-related traits in maize.
[Impedance characteristics of ear acupoints in identifying excess or deficiency syndrome of stroke].
Wang, Pin; Yang, Hua-Yuan; Wang, Yi-Qin
2010-06-01
To explore the impedance characteristics of ear acupoints in stroke patients with excess or deficiency syndrome, and to provide basis data for objective study of the syndromes of stroke. The data of electrical characteristics of ear acupoints in stroke patients and healthy people were collected, and excess syndrome and deficiency syndrome of stroke were identified by quantifying the syndromes of stroke using scales. The differences in impedance characteristics of ear acupoints between stroke patients and healthy people were analyzed, and the differences in impedance characteristics of ear acupoints between stroke patients with excess syndrome and stroke patients with deficiency syndrome were analyzed too. The correlation among impedance characteristics of ear acupoints, stroke and the syndromes was also analyzed. There were significant differences in impedance characteristics of ear acupoints between stroke patients and healthy people (P<0.05,P<0.01). The ear acupoints CO12 (Gan) and CO13 (Pi) had a significant role in diagnosing stroke as compared with CO18 (Neifenmi), AT3.4.AH12i (Naogan), CO10 (Shen), TG2p (Shenshangxian), AH6a (Jiaogan), AT4 (Pizhixia), and CO15 (Xin). There were significant differences in impedance characteristics of ear acupoints between stroke patients with excess syndrome and stroke patients with deficiency syndrome (P<0.05, P<0.01). The ear acupoints AH6a (Jiaogan) and CO10 (Shen) played an important role in differentiation diagnosis of excess syndrome and deficiency syndrome of stroke, followed by CO18 (Neifenmi), TF4 (Shenmen) and TG2p (Shenshangxian). Some ear acupoints with diagnostic value for stroke may provide basis of objective research for stroke diagnosis as well as identifying excess syndrome and deficiency syndrome of stroke.
Shu, Yilai; Tao, Yong; Wang, Zhengmin; Tang, Yong; Li, Huawei; Dai, Pu; Gao, Guangping; Chen, Zheng-Yi
2016-01-01
The mammalian inner ear consists of diverse cell types with important functions. Gene mutations in these diverse cell types have been found to underlie different forms of genetic hearing loss. Targeting these mutations for gene therapy development represents a future therapeutic strategy to treat hearing loss. Adeno-associated viral (AAV) vectors have become the vector of choice for gene delivery in animal models in vivo. To identify AAV vectors that target inner ear cell subtypes, we systemically screened 12 AAV vectors with different serotypes (AAV1, 2, 5, 6, 6.2, 7, 8, 9, rh.8, rh.10, rh.39, and rh.43) that carry a reporter gene GFP in neonatal and adult mice by microinjection in vivo. We found that most AAVs infect both neonatal and adult inner ear, with different specificities and expression levels. The inner ear cochlear sensory epithelial region, which includes auditory hair cells and supporting cells, is most frequently targeted for gene delivery. Expression of the transgene is sustained, and neonatal inner ear delivery does not adversely affect hearing. Adult inner ear injection of AAV has a similar infection pattern as the younger inner ear, with the exception that outer hair cell death caused by the injection procedure can lead to hearing loss. In the adult, more so than in the neonatal mice, cell types infected and efficiency of infection are correlated with the site of injection. Most infected cells survive in neonatal and adult inner ears. The study adds to the list of AAV vectors that transduce the mammalian inner ear efficiently, providing the tools that are important to study inner ear gene function and for the development of gene therapy to treat hearing loss. PMID:27342665
Sound transmission in archaic and modern whales: anatomical adaptations for underwater hearing.
Nummela, Sirpa; Thewissen, J G M; Bajpai, Sunil; Hussain, Taseer; Kumar, Kishor
2007-06-01
The whale ear, initially designed for hearing in air, became adapted for hearing underwater in less than ten million years of evolution. This study describes the evolution of underwater hearing in cetaceans, focusing on changes in sound transmission mechanisms. Measurements were made on 60 fossils of whole or partial skulls, isolated tympanics, middle ear ossicles, and mandibles from all six archaeocete families. Fossil data were compared with data on two families of modern mysticete whales and nine families of modern odontocete cetaceans, as well as five families of noncetacean mammals. Results show that the outer ear pinna and external auditory meatus were functionally replaced by the mandible and the mandibular fat pad, which posteriorly contacts the tympanic plate, the lateral wall of the bulla. Changes in the ear include thickening of the tympanic bulla medially, isolation of the tympanoperiotic complex by means of air sinuses, functional replacement of the tympanic membrane by a bony plate, and changes in ossicle shapes and orientation. Pakicetids, the earliest archaeocetes, had a land mammal ear for hearing in air, and used bone conduction underwater, aided by the heavy tympanic bulla. Remingtonocetids and protocetids were the first to display a genuine underwater ear where sound reached the inner ear through the mandibular fat pad, the tympanic plate, and the middle ear ossicles. Basilosaurids and dorudontids showed further aquatic adaptations of the ossicular chain and the acoustic isolation of the ear complex from the skull. The land mammal ear and the generalized modern whale ear are evolutionarily stable configurations, two ends of a process where the cetacean mandible might have been a keystone character. 2007 Wiley-Liss, Inc.
Trune, Dennis R.; Kempton, Beth; Hausman, Frances A.; Larrain, Barbara E.; MacArthur, Carol J.
2015-01-01
Although the inner ear has long been reported to be susceptible to middle ear disease, little is known of the inflammatory mechanisms that might cause permanent sensorineural hearing loss. Recent studies have shown inner ear tissues are capable of expressing inflammatory cytokines during otitis media. However, little quantitative information is available concerning cytokine gene expression in the inner ear and the protein products that result. Therefore, this study was conducted of mouse middle and inner ear during acute otitis media to measure the relationship between inflammatory cytokine genes and their protein products with quantitative RT-PCR and ELISA, respectively. Balb/c mice were inoculated transtympanically with heat-killed Haemophilus influenzae and middle and inner ear tissues collected for either quantitative RT-PCR microarrays or ELISA multiplex arrays. mRNA for several cytokine genes was significantly increased in both the middle and inner ear at 6 hours. In the inner ear, these included MIP-2 (448 fold), IL-6 (126 fold), IL-1β (7.8 fold), IL-10 (10.7 fold), TNFα (1.8 fold), and IL-1α (1.5 fold). The 24 hour samples showed a similar pattern of gene expression, although generally at lower levels. In parallel, the ELISA showed the related cytokines were present in the inner ear at concentrations higher by 2 to 122 fold higher at 18 hours, declining slightly from there at 24 hours. Immunohistochemistry with antibodies to a number of these cytokines demonstrated they occurred in greater amounts in the inner ear tissues. These findings demonstrate considerable inflammatory gene expression and gene products in the inner ear following acute otitis media. These higher cytokine levels suggest one potential mechanism for the permanent hearing loss seen in some cases of acute and chronic otitis media. PMID:25922207
Trune, Dennis R; Kempton, Beth; Hausman, Frances A; Larrain, Barbara E; MacArthur, Carol J
2015-08-01
Although the inner ear has long been reported to be susceptible to middle ear disease, little is known of the inflammatory mechanisms that might cause permanent sensorineural hearing loss. Recent studies have shown inner ear tissues are capable of expressing inflammatory cytokines during otitis media. However, little quantitative information is available concerning cytokine gene expression in the inner ear and the protein products that result. Therefore, this study was conducted of mouse middle and inner ear during acute otitis media to measure the relationship between inflammatory cytokine genes and their protein products with quantitative RT-PCR and ELISA, respectively. Balb/c mice were inoculated transtympanically with heat-killed Haemophilus influenzae and middle and inner ear tissues collected for either quantitative RT-PCR microarrays or ELISA multiplex arrays. mRNA for several cytokine genes was significantly increased in both the middle and inner ear at 6 h. In the inner ear, these included MIP-2 (448 fold), IL-6 (126 fold), IL-1β (7.8 fold), IL-10 (10.7 fold), TNFα (1.8 fold), and IL-1α (1.5 fold). The 24 h samples showed a similar pattern of gene expression, although generally at lower levels. In parallel, the ELISA showed the related cytokines were present in the inner ear at concentrations higher by 2-122 fold higher at 18 h, declining slightly from there at 24 h. Immunohistochemistry with antibodies to a number of these cytokines demonstrated they occurred in greater amounts in the inner ear tissues. These findings demonstrate considerable inflammatory gene expression and gene products in the inner ear following acute otitis media. These higher cytokine levels suggest one potential mechanism for the permanent hearing loss seen in some cases of acute and chronic otitis media. Copyright © 2015 Elsevier B.V. All rights reserved.
Factors Affecting Loss of Tympanic Membrane Mobility in Acute Otitis Media Model of Chinchilla
Guan, Xiying; Chen, Yongzheng; Gan, Rong Z.
2014-01-01
Recently we reported that middle ear pressure (MEP), middle ear effusion (MEE), and ossicular changes each contribute to the loss of tympanic membrane (TM) mobility in a guinea pig model of acute otitis media (AOM) induced by S. pneumoniae (Guan and Gan, 2013). However, it is not clear how those factors vary along the course of the disease and whether those effects are reproducible in different species. In this study, a chinchilla AOM model was produced by transbullar injection of Haemophilus influenzae. Mobility of the TM at the umbo was measured by laser vibrometry in two treatment groups: 4 days (4D) and 8 days (8D) post inoculation. These time points represent relatively early and later phases of AOM. In each group, the vibration of the umbo was measured at three experimental stages: unopened, pressure-released, and effusion-removed ears. The effects of MEP and MEE and middle ear structural changes were quantified in each group by comparing the TM mobility at one stage with that of the previous stage. Our findings show that the factors affecting TM mobility do change with the disease time course. The MEP was the dominant contributor to reduction of TM mobility in 4D AOM ears, but showed little effect in 8D ears when MEE filled the tympanic cavity. MEE was the primary factor affecting TM mobility loss in 8D ears, but affected the 4D ears only at high frequencies. After the release of MEP and removal of MEE, residual loss of TM mobility was seen mainly at low frequencies in both 4D and 8D ears, and was associated with middle ear structural changes. Our findings establish that the factors contributing to TM mobility loss in the chinchilla ear were similar to those we reported previously for the guinea pig ears with AOM. Outcomes did not appear to differ between the two major bacterial species causing AOM in these animal models. PMID:24406734
Probing the Xenopus laevis inner ear transcriptome for biological function
2012-01-01
Background The senses of hearing and balance depend upon mechanoreception, a process that originates in the inner ear and shares features across species. Amphibians have been widely used for physiological studies of mechanotransduction by sensory hair cells. In contrast, much less is known of the genetic basis of auditory and vestibular function in this class of animals. Among amphibians, the genus Xenopus is a well-characterized genetic and developmental model that offers unique opportunities for inner ear research because of the amphibian capacity for tissue and organ regeneration. For these reasons, we implemented a functional genomics approach as a means to undertake a large-scale analysis of the Xenopus laevis inner ear transcriptome through microarray analysis. Results Microarray analysis uncovered genes within the X. laevis inner ear transcriptome associated with inner ear function and impairment in other organisms, thereby supporting the inclusion of Xenopus in cross-species genetic studies of the inner ear. The use of gene categories (inner ear tissue; deafness; ion channels; ion transporters; transcription factors) facilitated the assignment of functional significance to probe set identifiers. We enhanced the biological relevance of our microarray data by using a variety of curation approaches to increase the annotation of the Affymetrix GeneChip® Xenopus laevis Genome array. In addition, annotation analysis revealed the prevalence of inner ear transcripts represented by probe set identifiers that lack functional characterization. Conclusions We identified an abundance of targets for genetic analysis of auditory and vestibular function. The orthologues to human genes with known inner ear function and the highly expressed transcripts that lack annotation are particularly interesting candidates for future analyses. We used informatics approaches to impart biologically relevant information to the Xenopus inner ear transcriptome, thereby addressing the impediment imposed by insufficient gene annotation. These findings heighten the relevance of Xenopus as a model organism for genetic investigations of inner ear organogenesis, morphogenesis, and regeneration. PMID:22676585
Munro, K J; Lazenby, A
2001-10-01
The electroacoustic characteristics of a hearing instrument are normally selected for individuals using data obtained during audiological assessment. The precise inter-relationship between the electroacoustic and audiometric variables is most readily appreciated when they have been measured at the same reference point, such as the tympanic membrane. However, it is not always possible to obtain the real-ear sound pressure level (SPL) directly if this is below the noise floor of the probe-tube microphone system or if the subject is unco-operative. The real-ear SPL may be derived by adding the subject's real-ear to dial difference (REDD) acoustic transform to the audiometer dial setting. The aim of the present study was to confirm the validity of the Audioscan RM500 to measure the REDD with the ER-3A insert earphone. A probe-tube microphone was used to measure the real-ear SPL and REDD from the right ears of 16 adult subjects ranging in age from 22 to 41 years (mean age 27 years). Measurements were made from 0.25 kHz to 6 kHz at a dial setting of 70 dB with an ER-3A insert earphone and two earmould configurations: the EAR-LINK foam ear-tip and the subjects' customized skeleton earmoulds. Mean REDD varied as a function of frequency but was typically approximately 12 dB with a standard deviation (SD) of +/- 1.7 dB and +/- 2.7 dB for the foam ear-tip and customized earmould, respectively. The mean test-retest difference of the REDD varied with frequency but was typically 0.5 dB (SD 1 dB). Over the frequency range 0.5-4 kHz, the derived values were found to be within 5 dB of the measured values in 95% of subjects when using the EAR-LINK foam ear-tip and within 4 dB when using the skeleton earmould. The individually measured REDD transform can be used in clinical practice to derive a valid estimate of real-ear SPL when it has not been possible to measure this directly.
Byers, John A
2008-09-01
The release rate of a semiochemical lure that attracts flying insects has a specific effective attraction radius (EAR) that corresponds to the lure's orientation response strength. EAR is defined as the radius of a passive sphere that intercepts the same number of insects as a semiochemical-baited trap. It is estimated by calculating the ratio of trap catches in the field in baited and unbaited traps and the interception area of the unbaited trap. EAR serves as a standardized method for comparing the attractive strengths of lures that is independent of population density. In two-dimensional encounter rate models that are used to describe insect mass trapping and mating disruption, a circular EAR (EAR(c)) describes a key parameter that affects catch or influence by pheromone in the models. However, the spherical EAR, as measured in the field, should be transformed to an EAR(c) for appropriate predictions in such models. The EAR(c) is calculated as (pi/2EAR(2))/F (L), where F (L) is the effective thickness of the flight layer where the insect searches. F (L) was estimated from catches of insects (42 species in the orders Coleoptera, Lepidoptera, Diptera, Hemiptera, and Thysanoptera) on traps at various heights as reported in the literature. The EAR(c) was proposed further as a simple but equivalent alternative to simulations of highly complex active-space plumes with variable response surfaces that have proven exceedingly difficult to quantify in nature. This hypothesis was explored in simulations where flying insects, represented as coordinate points, moved about in a correlated random walk in an area that contained a pheromone plume, represented as a sector of active space composed of a capture probability surface of variable complexity. In this plume model, catch was monitored at a constant density of flying insects and then compared to simulations in which a circular EAR(c) was enlarged until an equivalent rate was caught. This demonstrated that there is a circular EAR(c), where all insects that enter are caught, which corresponds in catch effect to any plume. Thus, the EAR(c), based on the field-observed EAR, can be used in encounter rate models to develop effective control programs based on mass trapping and/or mating disruption.
7 CFR 1755.501 - Definitions applicable to §§ 1755.501 through 1755.510.
Code of Federal Regulations, 2011 CFR
2011-01-01
... travel use built on or permanently attached to a self-propelled motor vehicle chassis or on a chassis cab... the FCC rules in 47 CFR part 68. NID. Network interface device. Primary station protector. An assembly... and determined that: (1) Final assembly or manufacture of the equipment is completed in the United...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-29
... process based on the average import value of other ferrous waste and scrap using HTSUS subheadings 7204.41... products) or unfinished (including green tubes and limited service OCTG products), whether or not thread...; drill pipe; unattached couplings; and unattached thread protectors. The merchandise subject to the...
The Effects of Hearing Protectors on Speech Communication and the Perception of Warning Signals
1989-06-01
situations, and cite Talamo (1982) as showing this problem with tractor drivers. Coleman Pt al. raise questions as to the practical significance of this...conditions: Toward a new theory of localization. J. Aud. Res., 16, 143-150, 1976. Talamo , J.D.C. Hearing in tractor cabs: Perception and directional effects
Facing the Future: A Doctrine for Air Control in Limited Conflicts
1998-06-01
defense of the Protectorate lay with one RAF squadron, three armoured cars and a few hundred local levies.”33 All air operations from 1934-1935 were under...Flight 655, Annapolis, Maryland: Naval Institute Press, 1992, pg. 4 “Vivid memories of a blackened hulk [USS Stark] and flag- draped coffins were never far
FIRE's Guide to Due Process and Fair Procedure on Campus. FIRE's Guides to Student Rights on Campus
ERIC Educational Resources Information Center
Silverglate, Harvey A.; Gewolb, Josh
2003-01-01
Students should know their rights and liberties, and they need to be better informed and better equipped about how to assert and defend these precious things. The protectors of students' rights and liberties--those faculty, administrators, parents, alumni, friends, citizens, advisors, and attorneys who care about such vital matters--should…
Resolving Conflicts of Interest in State-Owned Enterprises
ERIC Educational Resources Information Center
Radon, Jenik; Thaler, Julius
2005-01-01
State-owned enterprises (SOEs) face conflicts of interest that stem from a government's dual role as an owner, operator and businessman on the one hand and as the protector of the public interest and therefore a regulator of the SOE on the other hand. Besides pursuing profit maximisation like any private business, SOEs often have a mandate if not…
Bosnia-Herzegovina's Higher Education System: Issues of Governance and Quality
ERIC Educational Resources Information Center
Tiplic, Dijana; Welle-Strand, Anne
2006-01-01
Bosnia-Herzegovina (BiH) is seen as an intriguing case. Often described as a "miniature" of the Balkans due to its demographic pattern, the country has been exposed to a number of dramatic events during the past fifteen years. Today, international actors administer it as a sort of "semi-protectorate" concept, the definition of…
[Revisional radical mastoidectomy surgeries--25 cases'experience].
Li, L; Xie, J; Liu, Y; Gong, S S
2017-10-07
Objective: To analyze the risk factors of failure to dry ear after radical mastoidectomy and discuss key points in revisonal surgery. Methods: Clinical data of 25 patients(32 ears) with revisonal mastoidectomy were analyzed. The preoperative temporal bone CT findings, intra-operative findings, surgical procedures, postoperative operating cavities and aural abilities were recorded and analyzed. Results: All patients received preoperative temporal bone CT followed by revisonal radical mastoidectomy under microscope and general anesthesia. Among the revisonal surgeries, 19 ears(59.4%) presented cholesteatoma and 13 ears(40.6%) had no cholesteatoma. In addition, the inadequate opening for mastoid cavity and incompleted removal of the pathological tissues accounted for 90.6%(29/32), the insufficient drainage of surgical cavity for 90.6%(29/32), the lesions in tympanic ostium of eustachian tube for 31.2%(10/32), the improper operation procedures and selection of incision for 15.6%(5/32). As for the re-operation of the modified canal wall down mastoidectomy, tympanoplasty(Ⅱ) plus plastic repairing of cavity of concha were performed in 14 ears(43.8%), the modified canal wall down mastoidectomy, tympanoplasty(Ⅱ) plus reconstruction posterior bony wall of ear canal in 2 ears(6.2%); the modified canal wall down mastoidectomy, tympanoplasty(Ⅲ) plus plastic repairing of cavity of concha in 10 eras(31.3%), the modified canal wall down mastoidectomy, tympanoplasty(Ⅲ) plus reconstruction posterior boney wall of ear canal in 1 ear(3.1%); the radical mastoidectomy plus plastic repairing of cavity of concha in 5 ears(15.6%). Lodoform gauzes were packed in surgical cavity for 2 weeks and the antibiotic was used for 3 days after surgery. All patients had dressing of ears and their ears were dropped with ofloxacin regularly. The dry ear time ranged from 4 to 8 weeks, the average point was the 5th week. During a period of 6-18 months for follow-up, all patients got dried ears. The epithelialization of the operating cavity was well and the tympanic membranes were integrity. There was not pus in surgical cavities. Neither granulation tissue nor cholesteatoma was found to reoccur. Both pure tone air hearing thresholds and air-bone gap decreased in 27 ears after the revisional surgeries, with statistically significant different in comparison to those before the operation ( P <0.05). Conclusions: There are many factors leading to the failure of radical mastoidectomy, including not fully opening of the surgical cavity , incomplete removal of the lesion tissue, poor drainage of surgical cavity, the lesions in the tympanic ostium of eustachian tube, and the improper operation procedures. Treatment strategies were taken according to above factors to obtain dry ear in revisional surgeries.
Thomas, Megan L.A.; Fitzpatrick, Denis; McCreery, Ryan; Janky, Kristen L.
2017-01-01
Background Cervical and ocular Vestibular Evoked Myogenic Potentials (VEMPs) have become common clinical vestibular assessments. However, VEMP testing requires high intensity stimuli, raising concerns regarding safety with children, where sound pressure levels may be higher due to their smaller ear canal volumes. Purpose The purpose of this study was to estimate the range of peak-to-peak equivalent sound pressure levels (peSPLs) in child and adult ears in response to high intensity stimuli (i.e., 100 dB normal hearing level (nHL)) commonly used for VEMP testing and make a determination of whether acoustic stimuli levels with VEMP testing are safe for use in children. Research Design Prospective Experimental. Study Sample Ten children (4–6 years) and ten young adults (24 – 35 years) with normal hearing sensitivity and middle ear function participated in the study. Data Collection and Analysis Probe microphone peSPL measurements of clicks and 500 Hz tonebursts (TBs) were recorded in tubes of small, medium, and large diameter, and in a Brüel & Kjær Ear Simulator Type 4157 to assess for linearity of the stimulus at high levels. The different diameter tubes were used to approximate the range of cross-sectional areas in infant, child, and adult ears, respectively. Equivalent ear canal volume and peSPL measurements were then recorded in child and adult ears. Lower intensity levels were used in the participant’s ears to limit exposure to high intensity sound. The peSPL measurements in participant ears were extrapolated using predictions from linear mixed models to determine if equivalent ear canal volume significantly contributed to overall peSPL and to estimate the mean and 95% confidence intervals of peSPLs in child and adult ears when high intensity stimulus levels (100 dB nHL) are used for VEMP testing without exposing subjects to high-intensity stimuli. Results Measurements from the coupler and tubes suggested: 1) each stimuli was linear, 2) there were no distortions or non-linearities at high levels, and 3) peSPL increased with decreased tube diameter. Measurements in participant ears suggested: 1) peSPL was approximately 3 dB larger in child compared to adult ears, and 2) peSPL was larger in response to clicks compared to 500 Hz TBs. The model predicted the following 95% confidence interval for a 100 dB nHL click: 127–136.5 dB peSPL in adult ears and 128.7–138.2 dB peSPL in child ears. The model predicted the following 95% confidence interval for a 100 dB nHL 500 Hz TB stimulus: 122.2 – 128.2 dB peSPL in adult ears and 124.8–130.8 dB peSPL in child ears. Conclusions Our findings suggest that 1) when completing VEMP testing, the stimulus is approximately 3 dB higher in a child’s ear, 2) a 500 Hz TB is recommended over a click as it has lower peSPL compared to the click, and 3) both duration and intensity should be considered when choosing VEMP stimuli. Calculating the total sound energy exposure for your chosen stimuli is recommended as it accounts for both duration and intensity. When using this calculation for children, consider adding 3 dB to the stimulus level. PMID:28534730
Thomas, Megan L A; Fitzpatrick, Denis; McCreery, Ryan; Janky, Kristen L
2017-05-01
Cervical and ocular vestibular-evoked myogenic potentials (VEMPs) have become common clinical vestibular assessments. However, VEMP testing requires high intensity stimuli, raising concerns regarding safety with children, where sound pressure levels may be higher due to their smaller ear canal volumes. The purpose of this study was to estimate the range of peak-to-peak equivalent sound pressure levels (peSPLs) in child and adult ears in response to high intensity stimuli (i.e., 100 dB normal hearing level [nHL]) commonly used for VEMP testing and make a determination of whether acoustic stimuli levels with VEMP testing are safe for use in children. Prospective experimental. Ten children (4-6 years) and ten young adults (24-35 years) with normal hearing sensitivity and middle ear function participated in the study. Probe microphone peSPL measurements of clicks and 500 Hz tonebursts (TBs) were recorded in tubes of small, medium, and large diameter, and in a Brüel & Kjær Ear Simulator Type 4157 to assess for linearity of the stimulus at high levels. The different diameter tubes were used to approximate the range of cross-sectional areas in infant, child, and adult ears, respectively. Equivalent ear canal volume and peSPL measurements were then recorded in child and adult ears. Lower intensity levels were used in the participant's ears to limit exposure to high intensity sound. The peSPL measurements in participant ears were extrapolated using predictions from linear mixed models to determine if equivalent ear canal volume significantly contributed to overall peSPL and to estimate the mean and 95% confidence intervals of peSPLs in child and adult ears when high intensity stimulus levels (100 dB nHL) are used for VEMP testing without exposing subjects to high-intensity stimuli. Measurements from the coupler and tubes suggested: 1) each stimuli was linear, 2) there were no distortions or nonlinearities at high levels, and 3) peSPL increased with decreased tube diameter. Measurements in participant ears suggested: 1) peSPL was approximately 3 dB larger in child compared to adult ears, and 2) peSPL was larger in response to clicks compared to 500 Hz TBs. The model predicted the following 95% confidence interval for a 100 dB nHL click: 127-136.5 dB peSPL in adult ears and 128.7-138.2 dB peSPL in child ears. The model predicted the following 95% confidence interval for a 100 dB nHL 500 Hz TB stimulus: 122.2-128.2 dB peSPL in adult ears and 124.8-130.8 dB peSPL in child ears. Our findings suggest that 1) when completing VEMP testing, the stimulus is approximately 3 dB higher in a child's ear, 2) a 500 Hz TB is recommended over a click as it has lower peSPL compared to the click, and 3) both duration and intensity should be considered when choosing VEMP stimuli. Calculating the total sound energy exposure for your chosen stimuli is recommended as it accounts for both duration and intensity. When using this calculation for children, consider adding 3 dB to the stimulus level. American Academy of Audiology
Banding of Asio Owls in south-central Saskatchewan
C. Stuart Houston
1997-01-01
During a long-term Great Horned Owl (Bubo virginianus) banding program, 1946-1996, there were opportunities to band 507 Long-eared Owls (Asio otus) and 246 Short-eared Owls (Asio flammeus). No less than 35.1 percent of the Long-eared Owls and 63.5 percent of the Short-eared Owls were banded in two unusual years,...
"Epic Ear Defence"-A Game to Educate Children on the Risks of Noise-Related Hearing Loss.
Eikelboom, Robert H; Leishman, Natalie F; Munro, Tyler J; Nguyen, Bach; Riggs, Peter R; Tennant, Jonathon; West, Rhiannon K; Robertson, William B
2012-12-01
Hearing loss resulting from overexposure to entertainment-related sounds is a modern concern. "Epic Ear Defence" places the player in the three-dimensional environment of the ear canal and challenges the player to defend the ear from various noises, to delay the onset of noise-related hearing loss.
15 CFR 734.2 - Important EAR terms and principles.
Code of Federal Regulations, 2010 CFR
2010-01-01
... technology and software not subject to the EAR are described in §§ 734.7 through 734.11 and supplement no. 1... of items subject to the EAR out of the United States, or release of technology or software subject to... source code and object code software subject to the EAR. (2) Export of technology or software. (See...
15 CFR 734.2 - Important EAR terms and principles.
Code of Federal Regulations, 2012 CFR
2012-01-01
... technology and software not subject to the EAR are described in §§ 734.7 through 734.11 and supplement no. 1... of items subject to the EAR out of the United States, or release of technology or software subject to... source code and object code software subject to the EAR. (2) Export of technology or software. (See...
15 CFR 734.2 - Important EAR terms and principles.
Code of Federal Regulations, 2014 CFR
2014-01-01
... technology and software not subject to the EAR are described in §§ 734.7 through 734.11 and supplement no. 1... of items subject to the EAR out of the United States, or release of technology or software subject to... source code and object code software subject to the EAR. (2) Export of technology or software. (See...
15 CFR 734.2 - Important EAR terms and principles.
Code of Federal Regulations, 2013 CFR
2013-01-01
... technology and software not subject to the EAR are described in §§ 734.7 through 734.11 and supplement no. 1... of items subject to the EAR out of the United States, or release of technology or software subject to... source code and object code software subject to the EAR. (2) Export of technology or software. (See...
15 CFR 734.2 - Important EAR terms and principles.
Code of Federal Regulations, 2011 CFR
2011-01-01
... technology and software not subject to the EAR are described in §§ 734.7 through 734.11 and supplement no. 1... of items subject to the EAR out of the United States, or release of technology or software subject to... source code and object code software subject to the EAR. (2) Export of technology or software. (See...
The Octave Illusion Revisited Again
ERIC Educational Resources Information Center
Deutsch, Diana
2004-01-01
The octave illusion (D. Deutsch, 1974) occurs when 2 tones separated by an octave are alternated repeatedly, such that when the right ear receives the high tone, the left ear receives the low tone, and vice versa. Most subjects in the original study reported hearing a single tone that alternated from ear to ear, whose pitch also alternated from…
USDA-ARS?s Scientific Manuscript database
Stenocarpella ear rot (formerly Diplodia ear rot) is resurfacing as a concern in the central United States Corn Belt. There are reports of some fields containing more than 50% mummified ears. Ears infected within two weeks of silking may be completely mummified with white to grayish brown mycelium c...
Postganglionic horner syndrome in three patients with coincident middle ear infection.
Spector, Robert H
2008-09-01
Three patients developed a postganglionic Horner syndrome during the course of an ipsilateral uncomplicated middle ear infection. The mechanism may be an effect on the middle ear caroticotympanic sympathetic plexus, for which there is considerable anatomic and physiologic evidence. Why Horner syndrome does not occur more often after middle ear infection is a mystery.
Piercing the upper ear: a simple infection, a difficult reconstruction.
Cicchetti, S; Skillman, J; Gault, D T
2002-04-01
Piercing the upper ear to retain jewellery is now commonplace. When infection ensues, devastating chondritis leads to collapse of the ear. To our knowledge, the surgical reconstruction of post-piercing deformities has not been documented in the literature. We present five such cases referred for autogenous-tissue ear reconstruction. In four of these, the destroyed segments of ear cartilage were replaced with a carved costal-cartilage framework. One patient declined surgery. The importance of preventing infection is stressed. Copyright 2002 The British Association of Plastic Surgeons.
Molecular mechanisms of inner ear development.
Wu, Doris K; Kelley, Matthew W
2012-08-01
The inner ear is a structurally complex vertebrate organ built to encode sound, motion, and orientation in space. Given its complexity, it is not surprising that inner ear dysfunction is a relatively common consequence of human genetic mutation. Studies in model organisms suggest that many genes currently known to be associated with human hearing impairment are active during embryogenesis. Hence, the study of inner ear development provides a rich context for understanding the functions of genes implicated in hearing loss. This chapter focuses on molecular mechanisms of inner ear development derived from studies of model organisms.
CHIRTEŞ, FELICIAN; ALBU, SILVIU
2013-01-01
Intratympanic drug delivery refers to drug administration in the middle ear, the main advantage being direct diffusion of substances in the inner ear through the round window membrane with subsequent high intralabiryntine drug concentration and very low systemic side effects. The article is a review of literature concerning the inner ear barrier systems, the physiology of inner ear fluids, intralabirinthine pharmacokinetics and the commonest drugs applied in the middle ear for the treatment of cochleo-vestibular syndromes. PMID:26527944
An Effective 3D Ear Acquisition System
Liu, Yahui; Lu, Guangming; Zhang, David
2015-01-01
The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. It can be easily captured from a distance without a fully cooperative subject. Also, the ear has a relatively stable structure that does not change much with the age and facial expressions. In this paper, we present a novel method of 3D ear acquisition system by using triangulation imaging principle, and the experiment results show that this design is efficient and can be used for ear recognition. PMID:26061553
An Effective 3D Ear Acquisition System.
Liu, Yahui; Lu, Guangming; Zhang, David
2015-01-01
The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. It can be easily captured from a distance without a fully cooperative subject. Also, the ear has a relatively stable structure that does not change much with the age and facial expressions. In this paper, we present a novel method of 3D ear acquisition system by using triangulation imaging principle, and the experiment results show that this design is efficient and can be used for ear recognition.
The division of attention and the human auditory evoked potential
NASA Technical Reports Server (NTRS)
Hink, R. F.; Van Voorhis, S. T.; Hillyard, S. A.; Smith, T. S.
1977-01-01
The sensitivity of the scalp-recorded, auditory evoked potential to selective attention was examined while subjects responded to stimuli presented to one ear (focused attention) and to both ears (divided attention). The amplitude of the N1 component was found to be largest to stimuli in the ear upon which attention was to be focused, smallest to stimuli in the ear to be ignored, and intermediate to stimuli in both ears when attention was divided. The results are interpreted as supporting a capacity model of attention.
NASA Astrophysics Data System (ADS)
Dalhoff, Ernst; Turcanu, Diana; Gummer, Anthony W.
2009-02-01
Using distortion products measured as vibration of the umbo and as sound pressure in the ear canal of guinea pigs, we calculated the corresponding reverse transfer function. We compare the measurements with a middle-ear model taken from the literature and adapted to the guinea pig. A reasonable fit could be achieved. We conclude that the reverse transfer function will be useful to aid fitting a middle-ear model to measured transfer functions of human subjects.
Zhang, H M; Hui, G Q; Luo, Q; Sun, Y; Liu, X H
2014-01-21
Maize (Zea mays L.) is one of the most important crops in the world. In this study, 13 agronomic traits of a recombinant inbred line population that was derived from the cross between Mo17 and Huangzao4 were investigated in maize: ear diameter, ear length, ear axis diameter, ear weight, plant height, ear height, days to pollen shed (DPS), days to silking (DS), the interval between DPS and DS, 100-kernel weight, kernel test weight, ear kernel weight, and kernel rate. Furthermore, the descriptive statistics and correlation analysis of the 13 traits were performed using the SPSS 11.5 software. The results providing the phenotypic data here are needed for the quantitative trait locus mapping of these agronomic traits.
... this page: //medlineplus.gov/ency/article/002867.htm Elephant ear poisoning To use the sharing features on this page, please enable JavaScript. Elephant ear plants are indoor or outdoor plants with ...