Sample records for ear surgery simulator

  1. 3D-printed pediatric endoscopic ear surgery simulator for surgical training.

    PubMed

    Barber, Samuel R; Kozin, Elliott D; Dedmon, Matthew; Lin, Brian M; Lee, Kyuwon; Sinha, Sumi; Black, Nicole; Remenschneider, Aaron K; Lee, Daniel J

    2016-11-01

    Surgical simulators are designed to improve operative skills and patient safety. Transcanal Endoscopic Ear Surgery (TEES) is a relatively new surgical approach with a slow learning curve due to one-handed dissection. A reusable and customizable 3-dimensional (3D)-printed endoscopic ear surgery simulator may facilitate the development of surgical skills with high fidelity and low cost. Herein, we aim to design, fabricate, and test a low-cost and reusable 3D-printed TEES simulator. The TEES simulator was designed in computer-aided design (CAD) software using anatomic measurements taken from anthropometric studies. Cross sections from external auditory canal samples were traced as vectors and serially combined into a mesh construct. A modified tympanic cavity with a modular testing platform for simulator tasks was incorporated. Components were fabricated using calcium sulfate hemihydrate powder and multiple colored infiltrants via a commercial inkjet 3D-printing service. All components of a left-sided ear were printed to scale. Six right-handed trainees completed three trials each. Mean trial time (n = 3) ranged from 23.03 to 62.77 s using the dominant hand for all dissection. Statistically significant differences between first and last completion time with the dominant hand (p < 0.05) and average completion time for junior and senior residents (p < 0.05) suggest construct validity. A 3D-printed simulator is feasible for TEES simulation. Otolaryngology training programs with access to a 3D printer may readily fabricate a TEES simulator, resulting in inexpensive yet high-fidelity surgical simulation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. [Basics of Ear Surgery].

    PubMed

    Lailach, S; Zahnert, T

    2016-12-01

    The present article about the basics of ear surgery is a short overview of current indications, the required diagnostics and surgical procedures of common otologic diseases. In addition to plastic and reconstructive surgery of the auricle, principles of surgery of the external auditory canal, basics of middle ear surgery and the tumor surgery of the temporal bone are shown. Additionally, aspects of the surgical hearing rehabilitation (excluding implantable hearing systems) are presented considering current study results. Georg Thieme Verlag KG Stuttgart · New York.

  3. Cosmetic ear surgery

    MedlinePlus

    ... ear reduction. In: Rubin JP, Neligan PC, eds. Plastic Surgery: Volume 2: Aesthetic Surgery . 4th ed. Philadelphia, ... Tang Ho, MD, Assistant Professor, Division of Facial Plastic and Reconstructive Surgery, Department of Otolaryngology – Head and ...

  4. Principles of endoscopic ear surgery.

    PubMed

    Tarabichi, Muaaz; Kapadia, Mustafa

    2016-10-01

    The aim of this review is to study the rationale, limitations, techniques, and long-term outcomes of endoscopic ear surgery. The article discusses the advantages of endoscopic ear surgery in treating cholesteatoma and how the hidden sites like facial recess, sinus tympani, and anterior epitympanum are easily accessed using the endoscope. Transcanal endoscopic approach allows minimally invasive removal of cholesteatoma with results that compare well to traditional postauricular tympanomastoidectomy.

  5. A break-even analysis of major ear surgery.

    PubMed

    Wasson, J D; Phillips, J S

    2015-10-01

    To determine variables which affect cost and profit for major ear surgery and perform a break-even analysis. Retrospective financial analysis. UK teaching hospital. Patients who underwent major ear surgery under general anaesthesia performed by the senior author in main theatre over a 2-year period between dates of 07 September 2010 and 07 September 2012. Income, cost and profit for each major ear patient spell. Variables that affect major ear surgery profitability. Seventy-six patients met inclusion criteria. Wide variation in earnings, with a median net loss of £-1345.50 was observed. Income was relatively uniform across all patient spells; however, theatre time of major ear surgery at a cost of £953.24 per hour varied between patients and was the main determinant of cost and profit for the patient spell. Bivariate linear regression of earnings on theatre time identified 94% of variation in earnings was due to variation in theatre time (r = -0.969; P < 0.0001) and derived a break-even time for major ear surgery of 110.6 min. Theatre time was dependent on complexity of procedure and number of OPCS4 procedures performed, with a significant increase in theatre time when three or more procedures were performed during major ear surgery (P = 0.015). For major ear surgery to either break-even or return a profit, total theatre time should not exceed 110 min and 36 s. © 2015 John Wiley & Sons Ltd.

  6. Building an endoscopic ear surgery program.

    PubMed

    Golub, Justin S

    2016-10-01

    This article discusses background, operative details, and outcomes of endoscopic ear surgery. This information will be helpful for those establishing a new program. Endoscopic ear surgery is growing in popularity. The ideal benefit is in totally transcanal access that would otherwise require a larger incision. The endoscope carries a number of advantages over the microscope, as well as some disadvantages. Several key maneuvers can minimize disadvantages. There is a paucity of studies directly comparing outcomes between endoscopic and microscopic approaches for the same procedure. The endoscope is gaining acceptance as a tool for treating otologic diseases. For interested surgeons, this article can help bridge the transition from microscopic to totally transcanal endoscopic ear surgery for appropriate disease.

  7. Ear surgery - slideshow

    MedlinePlus

    ... Otolaryngology – Head and Neck Surgery, The University of Texas Medical School at Houston, Houston, TX. Also reviewed by David Zieve, MD, MHA, Medical Director, Brenda Conaway, Editorial Director, and the A.D.A.M. Editorial team. Related MedlinePlus Health Topics Ear Disorders ...

  8. Ear tube surgery - what to ask your doctor

    MedlinePlus

    What to ask your doctor about ear tube surgery; Tympanostomy - what to ask your doctor; Myringotomy - what to ask your doctor ... need ear tubes? Can we try other treatments? What are the risks of the surgery? Is it ...

  9. Assessment of skills using a virtual reality temporal bone surgery simulator.

    PubMed

    Linke, R; Leichtle, A; Sheikh, F; Schmidt, C; Frenzel, H; Graefe, H; Wollenberg, B; Meyer, J E

    2013-08-01

    Surgery on the temporal bone is technically challenging due to its complex anatomy. Precise anatomical dissection of the human temporal bone is essential and is fundamental for middle ear surgery. We assessed the possible application of a virtual reality temporal bone surgery simulator to the education of ear surgeons. Seventeen ENT physicians with different levels of surgical training and 20 medical students performed an antrotomy with a computer-based virtual temporal bone surgery simulator. The ease, accuracy and timing of the simulated temporal bone surgery were assessed using the automatic assessment software provided by the simulator device and additionally with a modified Final Product Analysis Scale. Trained ENT surgeons, physicians without temporal bone surgical training and medical students were all able to perform the antrotomy. However, the highly trained ENT surgeons were able to complete the surgery in approximately half the time, with better handling and accuracy as assessed by the significant reduction in injury to important middle ear structures. Trained ENT surgeons achieved significantly higher scores using both dissection analysis methods. Surprisingly, there were no significant differences in the results between medical students and physicians without experience in ear surgery. The virtual temporal bone training system can stratify users of known levels of experience. This system can be used not only to improve the surgical skills of trained ENT surgeons for more successful and injury-free surgeries, but also to train inexperienced physicians/medical students in developing their surgical skills for the ear.

  10. The visible ear simulator: a public PC application for GPU-accelerated haptic 3D simulation of ear surgery based on the visible ear data.

    PubMed

    Sorensen, Mads Solvsten; Mosegaard, Jesper; Trier, Peter

    2009-06-01

    Existing virtual simulators for middle ear surgery are based on 3-dimensional (3D) models from computed tomographic or magnetic resonance imaging data in which image quality is limited by the lack of detail (maximum, approximately 50 voxels/mm3), natural color, and texture of the source material.Virtual training often requires the purchase of a program, a customized computer, and expensive peripherals dedicated exclusively to this purpose. The Visible Ear freeware library of digital images from a fresh-frozen human temporal bone was segmented, and real-time volume rendered as a 3D model of high-fidelity, true color, and great anatomic detail and realism of the surgically relevant structures. A haptic drilling model was developed for surgical interaction with the 3D model. Realistic visualization in high-fidelity (approximately 125 voxels/mm3) and true color, 2D, or optional anaglyph stereoscopic 3D was achieved on a standard Core 2 Duo personal computer with a GeForce 8,800 GTX graphics card, and surgical interaction was provided through a relatively inexpensive (approximately $2,500) Phantom Omni haptic 3D pointing device. This prototype is published for download (approximately 120 MB) as freeware at http://www.alexandra.dk/ves/index.htm.With increasing personal computer performance, future versions may include enhanced resolution (up to 8,000 voxels/mm3) and realistic interaction with deformable soft tissue components such as skin, tympanic membrane, dura, and cholesteatomas-features some of which are not possible with computed tomographic-/magnetic resonance imaging-based systems.

  11. [Facial nerve monitoring during middle ear surgery: Results of a French survey].

    PubMed

    Mazzaschi, O; Juvanon, J-M; Mondain, M; Lavieile, J-P; Ayache, D

    2014-01-01

    Facial nerve injury is a rare complication of middle ear surgery. To date there is no widely accepted consensus on the use of intraoperative facial nerve monitoring during middle ear surgery, whereas its use has been proved as a valuable adjunct in neurotologic surgery. The purpose of our study was to identify introperative facial nerve monitoring practice patterns in France for middle ear surgery. A 19-item survey has been made up by three experienced otologists under the auspices of the French Otology and Neurotology Association. With the support of the French Society of Otolaryngology--Head and Neck Surgery, the survey was electronically sent by email to 1249 practicing ENT with a valid email address. Answers were analyzed two months later. Among 1249 email sent, 299 were opened (24%) and 83 answers were collected (6,6%). Of the respondents, 66% had access to intraoperative facial nerve monitoring. Otolaryngologists involved in academic setting were influenced by their teaching duty in 27%. Intraoperative facial nerve monitoring should not be required for stapes surgery, ossiculoplasty, myringoplasty for, respectively, 92%, 93 % and 98% of the respondents. In cochlear implantation, 78% of ear surgeons used facial nerve monitoring. Answers were more controversial for chronic ear surgery, ear atresia and middle ear implant. Revision surgery and CT scan can influence answers. Despite a low response rate, results of this national survey revealed interesting findings. For most of the respondents, intraoperative facial nerve monitoring was not indicated in stapes surgery, myringoplasty and ossiculoplasty. The use of intraoperative facial nerve monitoring for cochlear implantation was supported by the majority of respondents. Variations in response rate were more significant for chronic ear surgery, including middle ear cholesteatoma, and for ear atresia surgery.

  12. Direct cost comparison of totally endoscopic versus open ear surgery.

    PubMed

    Patel, N; Mohammadi, A; Jufas, N

    2018-02-01

    Totally endoscopic ear surgery is a relatively new method for managing chronic ear disease. This study aimed to test the null hypothesis that open and endoscopic approaches have similar direct costs for the management of attic cholesteatoma, from an Australian private hospital setting. A retrospective direct cost comparison of totally endoscopic ear surgery and traditional canal wall up mastoidectomy for the management of attic cholesteatoma in a private tertiary setting was undertaken. Indirect and future costs were excluded. A direct cost comparison of anaesthetic setup and resources, operative setup and resources, and surgical time was performed between the two techniques. Totally endoscopic ear surgery has a mean direct cost reduction of AUD$2978.89 per operation from the hospital perspective, when compared to canal wall up mastoidectomy. Totally endoscopic ear surgery is more cost-effective, from an Australian private hospital perspective, than canal wall up mastoidectomy for attic cholesteatoma.

  13. Gustatory otalgia and wet ear syndrome: a possible cross-innervation after ear surgery.

    PubMed

    Saito, H

    1999-04-01

    The chorda tympani and Arnold's nerves have close approximation to each other and their cross-innervation is possible after ear surgery. A retrospective study was performed with a temporal bone pathology case and two clinical cases as representatives of such a possibility. Patients had severe otalgia and wet ear during gustatory stimulation. A temporal bone pathology case was studied under a light microscope. Earache and/or wet ear were provoked during gustatory stimulation. Wet ear was tested with iodine-starch reaction after the subject tasted lemon juice. The temporal bone specimen has clusters of regenerated fibers in the tympanic cavity in the area of the chorda tympani and Arnold's nerves, suggesting a possibility of mixing. There are regenerated fibers in the iter chordae anterius, showing successful bridging of the chorda tympani nerves across a long gap. Detachment of the skin over the operated mastoid bowl obscured signs in one clinical case. Another clinical case of gustatory wet ear showed objective evidence of cross-innervation with iodine-starch reaction. The detachment procedure and iodine-starch reaction were the proofs that the signs were related to regenerated fibers. This is the first report of gustatory otalgia and wet ear after ear surgery.

  14. Ear surgery techniques results on hearing threshold improvement

    PubMed Central

    Mokhtarinejad, Farhad; Pour, Saeed Soheili; Nilforoush, Mohammad Hussein; Sepehrnejad, Mahsa; Mirelahi, Susan

    2013-01-01

    Background: Bone conduction (BC) threshold depression is not always by means of sensory neural hearing loss and sometimes it is an artifact caused by middle ear pathologies and ossicular chain problems. In this research, the influences of ear surgeries on bone conduction were evaluated. Materials and Methods: This study was conducted as a clinical trial study. The ear surgery performed on 83 patients classified in four categories: Stapedectomy, tympanomastoid surgery and ossicular reconstruction partially or totally; Partial Ossicular Replacement Prosthesis (PORP) and Total Ossicular Replacement Prosthesis (TORP). Bone conduction thresholds assessed in frequencies of 250, 500, 1000, 2000 and 4000 Hz pre and post the surgery. Results: In stapedectomy group, the average of BC threshold in all frequencies improved approximately 6 dB in frequency of 2000 Hz. In tympanomastoid group, BC threshold in the frequency of 500, 1000 and 2000 Hz changed 4 dB (P-value < 0.05). Moreover, In the PORP group, 5 dB enhancement was seen in 1000 and 2000 Hz. In TORP group, the results confirmed that BC threshold improved in all frequencies especially at 4000 Hz about 6.5 dB. Conclusion: In according to results of this study, BC threshold shift was seen after several ear surgeries such as stapedectomy, tympanoplasty, PORP and TORP. The average of BC improvement was approximately 5 dB. It must be considered that BC depression might happen because of ossicular chain problems. Therefore; by resolving middle ear pathologies, the better BC threshold was obtained, the less hearing problems would be faced. PMID:24381615

  15. Middle-ear microsurgery simulation to improve new robotic procedures.

    PubMed

    Kazmitcheff, Guillaume; Nguyen, Yann; Miroir, Mathieu; Péan, Fabien; Ferrary, Evelyne; Cotin, Stéphane; Sterkers, Olivier; Duriez, Christian

    2014-01-01

    Otological microsurgery is delicate and requires high dexterity in bad ergonomic conditions. To assist surgeons in these indications, a teleoperated system, called RobOtol, is developed. This robot enhances gesture accuracy and handiness and allows exploration of new procedures for middle ear surgery. To plan new procedures that exploit the capacities given by the robot, a surgical simulator is developed. The simulation reproduces with high fidelity the behavior of the anatomical structures and can also be used as a training tool for an easier control of the robot for surgeons. In the paper, we introduce the middle ear surgical simulation and then we perform virtually two challenging procedures with the robot. We show how interactive simulation can assist in analyzing the benefits of robotics in the case of complex manipulations or ergonomics studies and allow the development of innovative surgical procedures. New robot-based microsurgical procedures are investigated. The improvement offered by RobOtol is also evaluated and discussed.

  16. Middle-Ear Microsurgery Simulation to Improve New Robotic Procedures

    PubMed Central

    Kazmitcheff, Guillaume; Nguyen, Yann; Miroir, Mathieu; Péan, Fabien; Ferrary, Evelyne; Cotin, Stéphane; Sterkers, Olivier; Duriez, Christian

    2014-01-01

    Otological microsurgery is delicate and requires high dexterity in bad ergonomic conditions. To assist surgeons in these indications, a teleoperated system, called RobOtol, is developed. This robot enhances gesture accuracy and handiness and allows exploration of new procedures for middle ear surgery. To plan new procedures that exploit the capacities given by the robot, a surgical simulator is developed. The simulation reproduces with high fidelity the behavior of the anatomical structures and can also be used as a training tool for an easier control of the robot for surgeons. In the paper, we introduce the middle ear surgical simulation and then we perform virtually two challenging procedures with the robot. We show how interactive simulation can assist in analyzing the benefits of robotics in the case of complex manipulations or ergonomics studies and allow the development of innovative surgical procedures. New robot-based microsurgical procedures are investigated. The improvement offered by RobOtol is also evaluated and discussed. PMID:25157373

  17. Prevention and management of vascular complications in middle ear and cochlear implant surgery.

    PubMed

    Di Lella, Filippo; Falcioni, Maurizio; Piccinini, Silvia; Iaccarino, Ilaria; Bacciu, Andrea; Pasanisi, Enrico; Cerasti, Davide; Vincenti, Vincenzo

    2017-11-01

    The objective of this study is to illustrate prevention strategies and management of vascular complications from the jugular bulb (JB) and internal carotid artery (ICA) during middle ear surgery or cochlear implantation. The study design is retrospective case series. The setting is tertiary referral university hospital. Patients were included if presented pre- or intraoperative evidence of high-risk anatomical anomalies of ICA or JB during middle ear or cochlear implant surgery, intraoperative vascular injury, or revision surgery after the previous iatrogenic vascular lesions. The main outcome measures are surgical outcomes and complications rate. Ten subjects were identified: three underwent cochlear implant surgery and seven underwent middle ear surgery. Among the cochlear implant patients, two presented with anomalies of the JB impeding access to the cochlear lumen and one underwent revision surgery for incorrect positioning of the array in the carotid canal. Subtotal petrosectomy was performed in all cases. Anomalies of the JB were preoperatively identified in two patients with attic and external auditory canal cholesteatoma, respectively. In a patient, a high and dehiscent JB was found during myringoplasty, while another underwent revision surgery after iatrogenic injury of the JB. A dehiscent ICA complicated middle ear effusion in one case, while in another case, a carotid aneurysm determined a cholesterol granuloma. Rupture of a pseudoaneurysm of the ICA occurred in a child during second-stage surgery and required permanent balloon occlusion without neurological complications. Knowledge of normal anatomy and its variants and preoperative imaging are the basis for prevention of vascular complications during middle ear or cochlear implant surgery.

  18. [Complications and pitfalls in surgery of the ear/lateral skull base].

    PubMed

    Schick, B; Dlugaiczyk, J

    2013-04-01

    Surgery of the ear and the lateral skull base is a fascinating, yet challenging field in otorhinolaryngology. A thorough knowledge of the associated complications and pitfalls is indispensable for the surgeon, not only to provide the best possible care to his patients, but also to further improve his surgical skills.Following a summary about general aspects in pre-, intra- and postoperative care of patients with disorders of the ear/lateral skull base, this article covers the most common pitfalls and complications in stapes surgery, cochlear implantation, surgery of vestibular schwannomas, and jugulotympanal paragangliomas. Based on these exemplary procedures, basic "do's and don'ts" of skull base surgery are explained, which the reader can easily transfer to other disorders. Special emphasis is laid on functional aspects, such as hearing, balance and facial nerve function. Furthermore, the topics of infection, bleeding, skull base defects, quality of life and indication for revision surgery are discussed.An open communication about complications and pitfalls in ear/lateral skull base surgery among surgeons is a prerequisite for the further advancement of this fascinating field in ENT surgery. This article is meant to be a contribution to this process. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Transcanal endoscopic ear surgery for perilymphatic fistula after electric acoustic stimulation.

    PubMed

    Omichi, Ryotaro; Kariya, Shin; Maeda, Yukihide; Nishizaki, Kazunori

    2018-06-01

    Transcanal endoscopic ear surgery (TEES) will become a very useful therapeutic option. A perilymphatic fistula (PLF) is defined as sudden sensorineural hearing loss and/or vertigo caused by leakage of the perilymph through a fistula from the oval window and/or round window. We report a case of PLF after electric acoustic stimulation (EAS), a kind of cochlear implant, successfully treated by TEES. A 38-year-old man presented to our hospital with vertigo and hearing loss (HL). His vertigo was induced by Valsalva maneuvers. Eight months ago, he underwent EAS for his right ear for congenital sensorineural HL. Although he maintained his hearing level after EAS, his pure tone audiogram this time showed deterioration of hearing at low frequencies in his right ear. A diagnosis of right PLF was made. After confirming the non-effectiveness of oral prednisolone treatment, PLF repair surgery to patch the oval and round windows by TEES was performed. His vertigo did not recur after the surgery. To the best of our knowledge, this is the first report of PLF repair surgery by TEES without a microscope. The wide-field view of the middle ear by TEES was useful to prevent electrode damage in a PLF patient with a cochlear implant. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. YouTube as an information source for pediatric adenotonsillectomy and ear tube surgery.

    PubMed

    Sorensen, Jeffrey A; Pusz, Max D; Brietzke, Scott E

    2014-01-01

    Assess the overall quality of information on adenotonsillectomy and ear tube surgery presented on YouTube (www.youtube.com) from the perspective of a parent or patient searching for information on surgery. The YouTube website was systematically searched on select dates with a formal search strategy to identify videos pertaining to pediatric adenotonsillectomy and ear tube surgery. Only videos with at least 5 (ear tube surgery) or 10 (adenotonsillectomy) views per day were included. Each video was viewed and scored by two independent scorers. Videos were categorized by goal and scored for video/audio quality, accuracy, comprehensiveness, and procedure-specific content. Cross-sectional study. Public domain website. Fifty-five videos were scored for adenotonsillectomy and forty-seven for ear tube surgery. The most common category was educational (65.3%) followed by testimonial (28.4%), and news program (9.8%). Testimonials were more common for adenotonsillectomy than ear tube surgery (41.8% vs. 12.8%, p=0.001). Testimonials had a significantly lower mean accuracy (2.23 vs. 2.62, p=0.02), comprehensiveness (1.71 vs. 2.22, p=0.007), and TA specific content (0.64 vs. 1.69, p=0.001) score than educational type videos. Only six videos (5.9%) received high scores in both video/audio quality and accuracy/comprehensiveness of content. There was no significant association between the accuracy and comprehensive score and views, posted "likes", posted "dislikes", and likes/dislikes ratio. There was an association between "likes" and mean video quality (Spearman's rho=0.262, p=0.008). Parents/patients searching YouTube for information on pediatric adenotonsillectomy and ear tube surgery will generally encounter low quality information with testimonials being common but of significantly lower quality. Viewer perceived quality ("likes") did not correlate to formally scored content quality. Published by Elsevier Ireland Ltd.

  1. Risk factors for intraoperative bradycardia during ear, nose, throat and maxillofacial surgery.

    PubMed

    Ivošević, Tjaša; Miličić, Biljana; Dimitrijević, Milovan; Ivanović, Branislava; Pavlović, Aleksandar; Stojanović, Marina; Lakićević, Mirko; Stevanović, Ksenija; Kalezić, Nevena

    2018-02-01

    Intraoperative bradycardia (IOB) is one of the most common cardiac arrhythmias observed in clinical anaesthetic practice. Controlled hypotension, as a strategy of lowering patient's blood pressure during anesthesia has been practiced for decades in head and neck surgery. The aim of our study was to determine the incidence and the risk factors for intraoperative bradycardia in maxillofacial, ear, nose and throat surgery, as well as to determine whether controlled hypotension affects the occurrence of IOB. The retrospective study included 2304 patients who underwent maxillofacial, ear, nose or throat surgery. We studied the influence of: sex, age, comorbidity, type of surgery, duration of anesthesia and controlled hypotension on the occurrence of IOB. IOB was registered in 473 patients (20.5%). Patients with controlled hypotension had IOB significantly more often than patients without controlled hypotension (33.9 vs 15.1%) (p = 0.000). The significant predictors of IOB were: age (OR = 1.158; 95% CI = 1.068-1.256; p = 0.000), sex (OR = 0.786; 95% CI = 0.623-0.993; p = 0.043), ischemic heart disease (OR = 2.016; 95% CI = 1.182-3.441; p = 0.010); ear surgery (OR = 1.593; 95% CI = 1.232-2.060; p = 0.000), anesthesia duration, (OR = 1.006; 95% CI = 1.004-1.007; p = 0.000) and controlled hypotension (OR = 2.204; 95% CI = 1.761-2.758; p = 0.000). IOB is common in maxillofacial, ear, nose and throat surgery, particularly in male, older age and patients with ishemic heart disease. The ear surgery, longer anesthesia duration and controlled hypotension raise the risk for occurrence of IOB.

  2. Surgery of the ear and the lateral skull base: pitfalls and complications

    PubMed Central

    Schick, Bernhard; Dlugaiczyk, Julia

    2013-01-01

    Surgery of the ear and the lateral skull base is a fascinating, yet challenging field in otorhinolaryngology. A thorough knowledge of the associated complications and pitfalls is indispensable for the surgeon, not only to provide the best possible care to his patients, but also to further improve his surgical skills. Following a summary about general aspects in pre-, intra-and postoperative care of patients with disorders of the ear/lateral skull base, this article covers the most common pitfalls and complications in stapes surgery, cochlear implantation and surgery of vestibular schwannomas and jugulotympanal paragangliomas. Based on these exemplary procedures, basic “dos and don’ts” of skull base surgery are explained, which the reader can easily transfer to other disorders. Special emphasis is laid on functional aspects, such as hearing, balance and facial nerve function. Furthermore, the topics of infection, bleeding, skull base defects, quality of life and indication for revision surgery are discussed. An open communication about complications and pitfalls in ear/lateral skull base surgery among surgeons is a prerequisite for the further advancement of this fascinating field in ENT surgery. This article is meant to be a contribution to this process. PMID:24403973

  3. Effects of obstructive sleep apnea surgery on middle ear function.

    PubMed

    Lin, Hsin-Ching; Friedman, Michael; Chang, Hsueh-Wen; Shao, Chi-Hsin; Pulver, Tanya M; Chen, Yung-Che

    2011-04-01

    To study the effect of Z-palatopharyngoplasty plus radiofrequency of the base of the tongue on middle ear function. A retrospective review of a prospective data set at a tertiary care center. University-affiliated medical center. The study population included 47 patients (42 men and 5 women; mean age, 40.8 years) who underwent Z-palatopharyngoplasty plus radiofrequency of the base of the tongue for obstructive sleep apnea/hypopnea syndrome. All patients had healthy eardrums and no previous history of chronic ear disease. Pure-tone audiometric and tympanometric assessments were performed preoperatively and at 3 days, 7 days, 1 month, and 3 months postoperatively. Levels of baseline and postoperative middle ear pressure were compared. Twelve patients (26%) reported otologic concerns, such as ear pressure and/or otalgia, within 1 week postoperatively. No permanent otologic discomfort occurred. A trend toward reduced middle ear pressure was noted in this study. The decrease in middle ear pressure became apparent on day 3. However, mean pressure changes were no longer significantly different than preoperative values by 1 week after surgery. We found that Z-palatopharyngoplasty plus radiofrequency of the base of the tongue for obstructive sleep apnea/hypopnea syndrome induces changes in middle ear function. However, the changes were temporary and not significant after 3 months of follow-up.

  4. Prevalence and predictors of postoperative pain after ear, nose, and throat surgery.

    PubMed

    Sommer, Michael; Geurts, José W J M; Stessel, Bjorn; Kessels, Alfons G H; Peters, Madelon L; Patijn, Jacob; van Kleef, Maarten; Kremer, Bernd; Marcus, Marco A E

    2009-02-01

    To determine postoperative pain in different types of ear, nose, and throat (ENT) surgery and their psychological preoperative predictors. Prospective cohort study. Academic hospital. A total of 217 patients undergoing ENT surgery. All ENT, neck, and salivary gland surgery. Postoperative pain and predictors for postoperative pain. Fifty percent of the patients undergoing surgery on the oral, pharyngeal, and laryngeal region and on the neck and salivary gland region had a visual analog scale score higher than 40 mm on day 1. In the patients who underwent oropharyngeal region operations the VAS score remained high on all 4 days. A VAS pain score higher than 40 mm was found in less than 30% of patients after endoscopic procedures and less than 20% after ear and nose surgery. After bivariate analysis, 6 variables--age, sex, preoperative pain, expected pain, short-term fear, and pain catastrophizing--had a predictive value. Multivariate analysis showed only preoperative pain, pain catastrophizing, and anatomical site of operation as independent predictors. Differences exist in the prevalence of unacceptable postoperative pain between ENT operations performed on different anatomical sites. A limited set of variables can be used to predict the occurrence of unacceptable postoperative pain after ENT surgery.

  5. Proposal of a Budget-Friendly Camera Holder for Endoscopic Ear Surgery.

    PubMed

    Ozturan, Orhan; Yenigun, Alper; Aksoy, Fadlullah; Ertas, Burak

    2018-01-01

    Endoscopic ear surgery (EES) is increasingly a preferred technique in otologic society. It offers excellent visualization of the anatomical structures directly and behind the corners with variable angled telescopes. It also provides reduced operative morbidity due to being able to perform surgical interventions with less invasive approaches. Operative preparation and setup time and cost of endoscopy system are less expensive compared with surgical microscopes. On the other hand, the main disadvantage of EES is that the surgery has to be performed with 1 single hand. It is certainly restrictive for an ear surgeon who has been operating with 2 hands under otologic microscopic views for years and certainly requires a learning period and perseverance. Holding the endoscope by a second surgeon is not executable because of insufficient surgical space.Endoscope/camera holders have been developed for those who need the comfort and convenience afforded by double-handed microscopic ear surgery. An ideal endoscope holder should be easy-to-set up, easily controlled, providing a variety of angled views, allowing the surgeon to operate with 2 hands and, budget-friendly. In this article, a commercially available 11-inch magic arm camera holder is proposed by the authors to be used in EES due to its versatile, convenient, and budget-friendly features. It allows 2-handed EES through existing technology and is affordable for surgeons looking for a low-cost and practical solution.

  6. Principles of ear nose and throat surgery for pregnant women.

    PubMed

    Baruah, Paramita; Jasraj, Kailey; Ahmad, Ijaz

    2017-04-02

    Management of the pregnant surgical patient is challenging. The surgical procedure is usually postponed until the postpartum period, although this may not be possible in emergency situations. This article highlights the optimal management of the pregnant woman requiring ear nose and throat surgery.

  7. [Effect size on resonance of the outer ear canal by simulation of middle ear lesions using a temporal bone preparation].

    PubMed

    Scheinpflug, L; Vorwerk, U; Begall, K

    1995-01-01

    By means of a model of the external and the middle ear it is possible to simulate various, exactly defined pathological conditions of the middle ear and to describe their influence on ear canal resonance. Starting point of the investigations are fresh postmortem preparations of 8 human temporal bones with an intact ear drum and a retained skin of the ear canal. The compliance of the middle ear does not significantly differ from the clinical data of probands with healthy ears. After antrotomy it is possible to simulate pathological conditions of the middle ear one after the other at the same temporal bone. The influence of the changed middle ear conditions on ear drum compliance, ear canal volume and on the resonance curve of the external ear canal was investigated. For example, the middle ear was filled with water to create approximately the same conditions as in acute serous otitis media. In this middle ear condition a significant increase of the sound pressure amplification was found, on an average by 4 decibels compared to the unchanged temporal bone model. A small increase in resonance frequency was also measured. The advantages of this model are the approximately physiological conditions and the constant dimensions of the external and middle ear.

  8. Ear discharge

    MedlinePlus

    ... swabs or other small objects into the ear Middle ear infection Other causes of ear discharge include: Eczema ... tube surgery - what to ask your doctor Images Ear anatomy Eardrum repair - series References Bauer CA, Jenkins HA. Otologic symptoms and syndromes. In: Flint PW, Haughey BH, Lund V, et ...

  9. Middle Ear Infections and Ear Tube Surgery (For Parents)

    MedlinePlus

    ... Infection? Swimmer's Ear Perforated Eardrum Hearing Impairment Swimmer's Ear (External ... All information on KidsHealth® is for educational purposes only. For specific medical advice, diagnoses, and treatment, ...

  10. [Management of postoperative pain in ear-nose-throat surgery].

    PubMed

    Send, T; Bootz, F; Thudium, M O

    2013-10-01

    The degree of pain following different types of ear-nose-throat surgery varies greatly and must be adjusted on an individual basis. Post-operative pain therapy can be classified into basic pain therapy and additive pain therapy (as needed). Effective pain therapy can lead to lower morbidity and to considerable economic advantages. The subjective pain intensity experienced by patient should be the basis for the dose adaptation and is essential for rapid recovery.

  11. Ear Acupuncture for Post-Operative Pain Associated with Ambulatory Arthroscopic Knee Surgery: A Randomized Controlled Trial

    DTIC Science & Technology

    2014-01-14

    E7(/(3+21(180%(5 ,QFOXGHDUHDFRGH 14 Jan 2014 Final Report Ear acupuncture for post-operative pain associated with ambulatory arthroscopic...DISTRIBUTION A. Approved for public release: distribution unlimited. The purpose of this study is to compare ear acupuncture plus standard therapy versus...3298 Ear Acupuncture for Post-operative Pa111 Assoc1ated With Ambulatory Arthroscopic Knee Surgery A Randomized Controlled Trial ’• V ’’ ’-’ I

  12. Microbiomes of the normal middle ear and ears with chronic otitis media.

    PubMed

    Minami, Shujiro B; Mutai, Hideki; Suzuki, Tomoko; Horii, Arata; Oishi, Naoki; Wasano, Koichiro; Katsura, Motoyasu; Tanaka, Fujinobu; Takiguchi, Tetsuya; Fujii, Masato; Kaga, Kimitaka

    2017-10-01

    The aim of this study was to profile and compare the middle ear microbiomes of human subjects with and without chronic otitis media. Prospective multicenter cohort study. All consecutive patients undergoing tympanoplasty surgery for chronic otitis media or ear surgery for conditions other than otitis media were recruited. Sterile swab samples were collected from the middle ear mucosa during surgery. The variable region 4 of the 16S rRNA gene in each sample were amplified using region-specific primers adapted for the Illumina MiSeq sequencer (Illumina, CA, USA)). The sequences were subjected to local blast and classified using Metagenome@KIN (World Fusion, Tokyo, Japan). In total, 155 participants were recruited from seven medical centers. Of these, 88 and 67 had chronic otitis media and normal middle ears, respectively. The most abundant bacterial phyla on the mucosal surfaces of the normal middle ears were Proteobacteria, followed by Actinobacteria, Firmicutes, and Bacteroidetes. The children and adults with normal middle ears differed significantly in terms of middle ear microbiomes. Subjects with chronic otitis media without active inflammation (dry ear) had similar middle ear microbiomes as the normal middle ears group. Subjects with chronic otitis media with active inflammation (wet ear) had a lower prevalence of Proteobacteria and a higher prevalence of Firmicutes than the normal middle ears. The human middle ear is inhabited by more diverse microbial communities than was previously thought. Alteration of the middle ear microbiome may contribute to the pathogenesis of chronic otitis media with active inflammation. 2b. Laryngoscope, 127:E371-E377, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  13. Thermal effects of endoscopy in a human temporal bone model: Implications for endoscopic ear surgery

    PubMed Central

    Kozin, Elliott D.; Lehmann, Ashton; Carter, Margaret; Hight, Ed; Cohen, Michael; Nakajima, Hideko Heidi; Lee, Daniel J.

    2015-01-01

    Objective Although the theoretical risk of elevated temperatures during endoscopic ear surgery has been reported previously, neither temperature change nor heat distribution associated with the endoscope has been quantified. In this study, we measure temperature changes during rigid middle ear endoscopy in a human temporal bone model and investigate whether suction can act as a significant cooling mechanism. Study Design Human temporal bone model of endoscopic middle ear surgery. Methods Fresh human temporal bones were maintained at body temperature (~36°C). Temperature fluctuations were measured as a function of 1) distance between the tip of a 3mm 0° Hopkins rod and round window membrane, and 2) intensity of the light source. Infrared imaging determined the thermal gradient. For suction, a #20 French was utilized. Results We found: 1) an endoscope maximally powered by a xenon or LED light source resulted in a rapid temperature elevation up to 46°C within 0.5–1mm from the tip of the endoscope within 30–124 seconds; 2) elevated temperatures occurred up to 8mm from the endoscope tip; and 3) temperature decreased rapidly within 20–88 seconds of turning off the light source or applying suction. Conclusion Our findings have direct implications for avoiding excessive temperature elevation in endoscopic ear surgery. We recommend: 1) using submaximal light intensity, 2) frequent repositioning of the endoscope, and 3) removing the endoscope to allow tissue cooling. Use of suction provides rapid cooling of the middle ear space and may be incorporated in the design of new instrumentation for prolonged dissection. PMID:24604692

  14. Congenital middle ear abnormalities with absence of the oval window: diagnosis, surgery, and audiometric outcomes.

    PubMed

    Su, Yu; Yuan, Hu; Song, Yue-shuai; Shen, Wei-dong; Han, Wei-ju; Liu, Jun; Han, Dong-yi; Dai, Pu

    2014-08-01

    Congenital absence of the oval window (CAOW) is a rare condition in which the stapes footplate fails to develop, resulting in a significant conductive hearing loss in the affected ear. The purpose of this study was to describe the surgical management and outcomes of patients with CAOW undergoing the oval window drill-out (OWD) procedure. A retrospective chart review of patients with CAOW between 1996 and 2011 was performed. Clinical data of patients who underwent OWD were collected. Seventy-nine patients (103 ears) were confirmed using exploratory tympanotomy as having congenital stapes anomalies and CAOW without any anomalies of the tympanic membrane and external auditory canal. Demographic data, CT findings, operative findings, complications, and preoperative/postoperative audiometry data of patients who underwent OWD were collected. The preoperative and postoperative audiologic findings were analyzed in 42 patients (56 ears) with complete data. Hearing restoration surgery was aborted for various reasons in 14 cases. Six patients underwent revision operations for worsening hearing after their first surgery. The average preoperative 4 tone air conduction threshold was 67 dB; the average 6-month postoperative four tone air conduction threshold was 49 dB, and the average postoperative hearing gain was 18 dB. For the 56 ears, the average 4 tone air conduction threshold 6 months after surgery was significantly lower than the preoperative threshold. The oval window drill-out procedure is a viable operation for patients with congenital absence of the oval window, and it is important for surgeons to develop personalized treatment programs to improve patients' hearing with minimal complications.

  15. Controlled hypotension for middle ear surgery: a comparison between remifentanil and magnesium sulphate.

    PubMed

    Ryu, J-H; Sohn, I-S; Do, S-H

    2009-10-01

    This prospective, randomized study was designed to compare remifentanil and magnesium sulphate during middle ear surgery in terms of postoperative pain and other complications. Eighty patients undergoing middle ear surgery were enrolled in the study. Patients were randomized into two groups of 40 to receive remifentanil (Group R) or magnesium sulphate (Group M) infusion. Propofol 2 mg kg(-1) was administered to induce anaesthesia, which was maintained using sevoflurane. Group R received a continuous infusion of remifentanil titrated between 3 and 4 ng ml(-1) using target-controlled infusion, whereas Group M received an i.v. magnesium sulphate bolus of 50 mg kg(-1) followed by a 15 mg kg(-1) h(-1) continuous infusion to maintain a mean arterial pressure (MAP) between 60 and 70 mm Hg. Haemodynamic variables, surgical conditions, postoperative pain, and adverse effects, such as postoperative nausea and vomiting (PONV) and shivering, were recorded. Controlled hypotension was well maintained in both groups. MAP and heart rate were higher in Group R than in Group M after operation. Surgical conditions were not different between the two groups. Postoperative pain scores were significantly lower in Group M than in Group R (P<0.05). Seventeen patients in Group R (43%) and seven patients in Group M (18%) developed PONV (P=0.01). Both magnesium sulphate and remifentanil when combined with sevoflurane provided adequate controlled hypotension and proper surgical conditions for middle ear surgery. However, patients administered magnesium sulphate had a more favourable postoperative course with better analgesia and less shivering and PONV.

  16. A practical use of a 16-gauge peripheral angiocatheter as an aspiration cautery in endoscopic ear surgery.

    PubMed

    Ozdek, Ali; Keseroglu, Kemal

    2014-08-01

    To define a technique for the practical use of a 16-gauge peripheral venous catheter as an insulated aspiration cautery in endoscopic ear surgery. Retrospective case review. Tertiary referral center. A 16-gauge intravenous catheter was prepared as a cauterization instrument with aspiration. After simple rearrangement of the exterior plastic portion, it was connected to a suction system. With the help of an unipolar cautery, aspiration of the blood and homeostasis was achieved. Hemorrhage of the external ear canal skin after incision can be easily coagulated with this instrument. During follow-up, there were no wound infection, facial nerve paresis, scar formation, and inadvertent burn of the external canal and auricular skin. With the help of this instrument, bleeding control during incision can be easily maintained. It is a simple, easily prepared, and alternative homeostasis technique in endoscopic ear surgery.

  17. Active middle ear implant after lateral petrosectomy and radiotherapy for ear cancer.

    PubMed

    Cristalli, Giovanni; Sprinzl, Georg M; Wolf-Magele, Astrid; Marchesi, Paolo; Mercante, Giuseppe; Spriano, Giuseppe

    2014-04-01

    Tumor of the temporal bone is a rare disease with a very poor prognosis. Surgery and postoperative radiotherapy are usually the recommended treatments for squamous cell carcinoma (SCC) of the external and middle ear, which may cause conductive hearing loss. The purpose of this study was to evaluate the audiologic results and compliance of active middle ear implant (AMEI) and establish the feasibility of the procedure in a patient treated for middle ear cancer. A 73-year-old patient treated with lateral petrosectomy, neck dissection, reconstruction/obliteration by pedicled pectoralis major myocutaneous flap, and postoperative full dose radiotherapy for external and middle ear SCC was selected for AMEI. Preoperative audiometric and speech audiometry tests were performed on both ears before and after the activation. Pure tone free field audiometry. Binaural free field speech audiogram. Aided pure tone free field audiometry AMEI results show an increase in air conduction. Speech audiogram showed better discrimination scores in AMEI-aided situations. No complications were observed. AMEI after surgery followed by radiotherapy for middle ear cancer is feasible. Acoustic results in obliterated ear are satisfactory.

  18. Simulating Reflex Induced Changes in the Acoustic Impedance of the Ear.

    ERIC Educational Resources Information Center

    Sirlin, Mindy W.; Levitt, Harry

    1991-01-01

    A simple procedure for measuring changes in the acoustic impedance of the ear is described. The technique has several applications, including simulation using a standard coupler of changes in real ear impedance produced by the acoustic reflex, and calibration of response time of an otoadmittance meter. (Author/DB)

  19. Ear infection - chronic

    MedlinePlus

    Middle ear infection - chronic; Otitis media - chronic; Chronic otitis media; Chronic ear infection ... Chole RA. Chronic otitis media, mastoiditis, and petrositis. In: Flint PW, Haughey BH, Lund V, et al, eds. Cummings Otolaryngology: Head & Neck Surgery . 6th ed. ...

  20. Comparison of methods of evaluating hearing benefit of middle ear surgery.

    PubMed

    Toner, J G; Smyth, G D

    1993-01-01

    The objective of this paper is to compare two methods of predicting the level of subjective patient benefit following reconstructive middle ear surgery. This should have always been an important consideration in advising patients regarding surgery, but assumes even more relevance in these days of clinical audit and cost benefit analysis. The two methods studied were the '15/30 dB rule of thumb' (Smyth and Patterson, 1985) and the 'Glasgow plot' (Browning et al., 1991). The predictions of benefit for each of the two methods were compared to the assessment of actual benefits by the patient post-operatively. The results of this comparison in 153 patients were analysed, the rule of thumb was found to be somewhat more sensitive in predicting patient benefit.

  1. Teasing in younger and older children with microtia before and after ear reconstruction.

    PubMed

    Johns, Alexis L; Lewin, Sheryl L; Im, Daniel D

    2017-06-01

    This study prospectively measured teasing and emotional adjustment before and after ear reconstruction in younger and older children with microtia. Participants with isolated microtia (n = 28) were divided into two groups by age at surgery, with a younger group aged 3-5 years (n = 13) with a mean age of 4.0 (0.71) years at the time of surgery and an older group aged 6-10 years old (n = 15) with a mean age of 7.87 (1.30) years. Children and their parents were interviewed preoperatively and a year after surgery about teasing and emotions about their ear(s). Teasing began between the ages of 2.4-4.8 years. A third of the younger group and all of the older group reported preoperative teasing. Before surgery, the older group reported higher rates of negative emotions about their ear(s) and teasing was correlated for all ages with feeling sad, worried, and mad about their ear(s). After surgery, teasing and negative emotions significantly decreased with increased happiness about their ear(s). Postoperative teasing was correlated with trying to hide their ear(s). There were significant interactions from before to after surgery based on surgery age for frequency of teasing, sadness, and feeling mad, with the older group showing relatively greater change postoperatively. Teasing and negative emotions about their ear(s) decreased for all ages after surgery, with a potential protective factor seen in younger surgery age.

  2. Chlorhexidine ototoxicity in ear surgery part II: survey of preparation solution used by otolaryngologists in Canada: is there a cause for concern?

    PubMed

    Lai, Philip; Coulson, Chris; Pothier, David; Rutka, John

    2011-12-01

    To conduct a survey of the antiseptic preparations used for ear surgeries among otolaryngologists in Canada. An electronic survey was sent to active members of the Canadian Society of Otolaryngology-Head and Neck Surgery via e-mail. Questions included the use of antiseptic, choice of preparation solution, duration of preparation, use of a barrier method, and compliance with hospital protocol changes. The e-mail was received by 253 otolaryngologists, and 85 completed the survey. Four of 85 respondents did not perform tympanoplasty surgery and were not included in the analysis. Of those who performed tympanoplasty (n  =  81), 78 of the 81 respondents (96%) used an antiseptic preparation solution at surgery, whereas 3 respondents (4%) did not. Sixty-six of the 77 respondents (86%) used aqueous povidone-iodine, 4 (5%) used a chlorhexidine-based preparation, 3 (4%) used an alcohol-based solution, 3 (4%) used others, and 1 answered "I don't know." Thirty-eight of 75 (29%) respondents used a barrier method, 23 (31%) answered "always," 18 (24%) answered "sometimes," and 5 (7%) answered "I don't know." When asked if they would comply with a hypothetical hospital policy to use chlorhexidine in ear surgery, 15 of 79 (19%) respondents agreed, whereas 64 (81%) disagreed. Among the aqueous povidone-iodine users (n  =  66), 7 (11%) agreed to change to chlorhexidine. There is a wide variation in practice in the use of surgical preparation solution among otolaryngologists performing ear surgery. Surgeons must be vigilant to avoid ototoxicity. A national society consensus on appropriate preparation solutions for ear surgery would minimize patients' risk and minimize future medicolegal actions.

  3. The effect of light intensity on image quality in endoscopic ear surgery.

    PubMed

    McCallum, R; McColl, J; Iyer, A

    2018-05-16

    Endoscopic ear surgery is a rapidly developing field with many advantages. But endoscopes can reach temperatures of over 110°C at the tip, raising safety concerns. Reducing the intensity of the light source reduces temperatures produced. However, quality of images at lower light intensities has not yet been studied. We set out to study the effect of light intensity on image quality in EES. Prospective study of patients undergoing EES from April to October 2016. Consecutive images of the same operative field at 10%, 30%, 50% and 100% light intensities were taken. Eight international experts were asked to each evaluate 100 anonymised, randomised images. District General Hospital. Twenty patients. Images were evaluated on a 5-point Likert scale (1 = significantly worse than average; 5 = significantly better than average) for detail of anatomy; colour contrast; overall quality; and suitability for operating. Mean scores for photographs at 10%, 30%, 50% and 100% light intensity were 3.22 (SD 0.93), 3.15 (SD 0.84), 3.08 (SD 0.88) and 3.10 (SD 0.86), respectively. In ANOVA models for the scores on each of the scales (anatomy, colour contrast, overall quality and suitability for operating), the effects of rater and patient were highly significant (P < .0005) but light intensity was non-significant (P = .34, .32, .21, .15, respectively). Images taken during surgery by our endoscope and operative camera have no loss of quality when taken at lower light intensities. We recommend the surgeon considers use of lower light intensities in endoscopic ear surgery. © 2018 John Wiley & Sons Ltd.

  4. A New Way for Antihelixplasty in Prominent Ear Surgery: Modified Postauricular Fascial Flap.

    PubMed

    Taş, Süleyman; Benlier, Erol

    2016-06-01

    Otoplasty procedures aim to reduce the concha-mastoid angle and recreate the antihelical fold. Here, we explained the modified postauricular fascial flap, described as a new way for recreating the antihelical fold, and reported the results of patients on whom this flap was used. The defined technique was used on 24 patients (10 females and 14 males; age, 6-27 years; mean, 16.7 years) between June 2009 and July 2012, a total of 48 procedures in total (bilateral). Follow-up ranged from 1 to 3 years (mean, 1.5 years). At the preoperative and postoperative time points (1 and 12 months after surgery), all patients were measured for upper and middle helix-head distance and were photographed. The records were analyzed statistically using t test and analysis of variance. The procedure resulted in ears that were natural in appearance without any significant visible evidence of surgery. The operations resulted in no complications except 1 patient who developed a small skin ulcer on the left ear because of band pressure. When we compared the preoperative and postoperative upper and middle helix-head distance, there was a high significance statistically. To introduce modified postauricular fascial flap, we used a simple and safe procedure to recreate an antihelical fold. This procedure led to several benefits, including a natural-in-appearance antihelical fold, prevention of suture extrusion and granuloma, as well as minimized risk for recurrence due to neochondrogenesis. This method may be used as a standard procedure for treating prominent ears surgically.

  5. Classification of Newborn Ear Malformations and their Treatment with the EarWell Infant Ear Correction System.

    PubMed

    Daniali, Lily N; Rezzadeh, Kameron; Shell, Cheryl; Trovato, Matthew; Ha, Richard; Byrd, H Steve

    2017-03-01

    A single practice's treatment protocol and outcomes following molding therapy on newborn ear deformations and malformations with the EarWell Infant Ear Correction System were reviewed. A classification system for grading the severity of constricted ear malformations was created on the basis of anatomical findings. A retrospective chart/photograph review of a consecutive series of infants treated with the EarWell System from 2011 to 2014 was undertaken. The infants were placed in either deformation or malformation groups. Three classes of malformation were identified. Data regarding treatment induction, duration of treatment, and quality of outcome were collected for all study patients. One hundred seventy-five infant ear malformations and 303 infant ear deformities were treated with the EarWell System. The average age at initiation of treatment was 12 days; the mean duration of treatment was 37 days. An average of six office visits was required. Treated malformations included constricted ears [172 ears (98 percent)] and cryptotia [three ears (2 percent)]. Cup ear (34 ears) was considered a constricted malformation, in contrast to the prominent ear deformity. Constricted ears were assigned to one of three classes, with each subsequent class indicating increasing severity: class I, 77 ears (45 percent); class II, 81 ears (47 percent); and class III, 14 ears (8 percent). Molding therapy with the EarWell System reduced the severity by an average of 1.2 points (p < 0.01). Complications included minor superficial excoriations and abrasions. The EarWell System was shown to be effective in eliminating or reducing the need for surgery in all but the most severe malformations. Therapeutic, IV.

  6. Prophylactic antiemetic effects of Midazolam, Ondansetron, and their combination after middle ear surgery.

    PubMed

    Honarmand, Azim; Safavi, Mohammadreza; Chegeni, Mansoureh; Hirmanpour, Anahita; Nazem, Masoud; Sarizdi, Seyyad Hamid

    2016-01-01

    The purpose of the present study was to evaluate the efficacy of midazolam-ondansetron combination in prevention of postoperative nausea and vomiting (PONV) after middle ear surgery and its comparison with using midazolam or ondansetron alone. One hundred and forty patients were enrolled in four groups to receive midazolam 0.75 mg/kg in group M, ondansetron 4 mg in group O, midazolam 0.75 mg/kg and ondansetron 4 mg in group MO, and saline 0.90% in group S intravenously just before anesthesia. Assessment of nausea, vomiting, rescue antiemetic, and side effects of study drugs such as headache and dizziness was carried out postoperatively for 24 h. The incidence of PONV was significantly smaller in group MO than group M and group O, while there was no significant difference between group M and group O during the first 24 h postoperatively. Requirement to the additional antiemetic was significantly more in group S (71.4%) compared to other groups, while in group MO (11.4%) was lower than group M (31.4%) and group O (34.3%). Our study showed that prophylactic administration of midazolam 0.75 mg/kg combined with ondansetron 4 mg was more effective than using midazolam or ondansetron alone in prevention of PONV after middle ear surgery.

  7. Pinnaplasty: reshaping ears to improve hearing aid retention.

    PubMed

    Gault, David; Grob, Marion; Odili, Joy

    2007-01-01

    The hearing aid is extremely important to the deaf. A small number have difficulty in retaining the device because the ear is prominent or cup-shaped. This report describes 11 children whose ear shape was modified to improve hearing aid retention and one adult in whom an over set back ear was released to allow fitment of a postaural device. In eight of the 11 children treated, conservative measures such as double-sided tape and retention bands (Huggies) had been tried previously without success. The creation of an antihelical fold in a misshapen ear lacking such a fold provides a reinforcing strut which is useful to support a hearing aid. In patients whose ear had been excessively tethered by previous surgery, projection was restored by inserting a cartilage block behind the ear. In one child with ears tethered by previous surgery, costal cartilage was used not only to release both ears, but also to reconstruct a new helical rim on one side. Surgery enabled a normal postaural hearing aid to be worn in 17 of the 19 ears treated. The two failures deserve special mention. In one patient with a unilateral deformity and severe mental retardation, the dressings were pulled off immediately after surgery. In another patient with a bilateral problem, the appearance and hearing aid retention was improved, but there was not enough room in the postauricular sulcus on one side for the battery component to fit comfortably and an in-the-ear device is now used on that side. Pinnaplasty is a helpful strategy to improve hearing aid retention. Care must be taken not to overdo the set back so that enough room is left to retain the hearing device.

  8. Quality of life of Nepali patients with ear disease before and after corrective surgery.

    PubMed

    Maile, Edward John; Tharu, Puran Bahadur; Blanchford, Hannah L K; Edmiston, Rachel; Youngs, Robin

    2015-08-01

    Hearing impairment is a significant burden in the developing world. However, no suitable quality of life (QoL) measures exist for use in Nepal. We aimed to amend and translate the Glasgow Health Status Inventory (GHSI), assessing QoL at any given time, and the Glasgow Benefit Inventory (GBI), assessing change in QoL following intervention, into Nepali and to assess the impact of ear disease and effect of surgery on QoL. The GHSI and GBI were translated into Nepali and independently verified. The GHSI was administered by interview to patients before surgery, and the GBI was administered 6 months after surgery. The Mann-Whitney U-test was used for hypothesis testing. The GHSI was administered to 242 patients. In total, 205 had chronic suppurative otitis media (CSOM) without cholesteatoma and 37 had cholesteatoma. The mean GHSI score was 47.9. There was no significant difference in GHSI scores between patients with CSOM without cholesteatoma and those with cholesteatoma. The GBI was administered to 161 patients, 73 of whom had also been in the GHSI group. In total, 130 had CSOM without cholesteatoma, 31 had cholesteatoma. The mean GBI score was +38.4 with no significant difference between disease groups. Ear disease in Nepal is associated with reduced QoL, and surgical intervention is associated with improved QoL. There is no difference in QoL or benefit following surgery for CSOM between patients with or without cholesteatoma. There are few QoL measures suitable for the developing world. It is essential to invest in these measures to guide health interventions. © 2015 John Wiley & Sons Ltd.

  9. Comparison of Middle Ear Visualization With Endoscopy and Microscopy.

    PubMed

    Bennett, Marc L; Zhang, Dongqing; Labadie, Robert F; Noble, Jack H

    2016-04-01

    The primary goal of chronic ear surgery is the creation of a safe, clean dry ear. For cholesteatomas, complete removal of disease is dependent on visualization. Conventional microscopy is adequate for most dissection, but various subregions of the middle ear are better visualized with endoscopy. The purpose of the present study was to quantitatively assess the improved visualization that endoscopes afford as compared with operating microscopes. Microscopic and endoscopic views were simulated using a three-dimensional model developed from temporal bone scans. Surface renderings of the ear canal and middle ear subsegments were defined and the percentage of visualization of each middle ear subsegment, both with and without ossicles, was then determined for the microscope as well as for 0-, 30-, and 45-degree endoscopes. Using this information, we analyzed which mode of visualization is best suited for dissection within a particular anatomical region. Using a 0-degree scope provides significantly more visualization of every subregion, except the antrum, compared with a microscope. In addition, angled scopes permit visualizing significantly more surface area of every subregion of the middle ear than straight scopes or microscopes. Endoscopes offer advantages for cholesteatoma dissection in difficult-to-visualize areas including the sinus tympani and epitympanum.

  10. Prophylactic antiemetic effects of Midazolam, Ondansetron, and their combination after middle ear surgery

    PubMed Central

    Honarmand, Azim; Safavi, Mohammadreza; Chegeni, Mansoureh; Hirmanpour, Anahita; Nazem, Masoud; Sarizdi, Seyyad Hamid

    2016-01-01

    Objective: The purpose of the present study was to evaluate the efficacy of midazolam-ondansetron combination in prevention of postoperative nausea and vomiting (PONV) after middle ear surgery and its comparison with using midazolam or ondansetron alone. Methods: One hundred and forty patients were enrolled in four groups to receive midazolam 0.75 mg/kg in group M, ondansetron 4 mg in group O, midazolam 0.75 mg/kg and ondansetron 4 mg in group MO, and saline 0.90% in group S intravenously just before anesthesia. Assessment of nausea, vomiting, rescue antiemetic, and side effects of study drugs such as headache and dizziness was carried out postoperatively for 24 h. Findings: The incidence of PONV was significantly smaller in group MO than group M and group O, while there was no significant difference between group M and group O during the first 24 h postoperatively. Requirement to the additional antiemetic was significantly more in group S (71.4%) compared to other groups, while in group MO (11.4%) was lower than group M (31.4%) and group O (34.3%). Conclusion: Our study showed that prophylactic administration of midazolam 0.75 mg/kg combined with ondansetron 4 mg was more effective than using midazolam or ondansetron alone in prevention of PONV after middle ear surgery. PMID:26985431

  11. Application criteria for infrared ear thermometers in pediatric surgery.

    PubMed

    Saxena, A K; Topp S, S; Heinecke, A; Willital, G H

    2001-01-01

    Fever is an important and sensitive indicator of infectious diseases in children. For the past decades, measurement of body temperature in routine medical practice was limited to oral, rectal and axillary sites. In infants and children, however, temperature measurements are further limited to the rectal and axillary sites due to technical and clinical considerations. In the field of pediatric surgery, pathological and surgical conditions of the ano-rectal area often further restrict the application of conventional rectal temperature measurements. The application of tympanic temperature measurements in such pediatric surgical pathologies provides a reliable alternative to conventional rectal temperature measurements. The pediatric surgical clinico-pathological states where ear temperature measurements are the only mode of accurate temperature determination have been identified. Tympanic thermometry is well tolerated by children and predicts temperature with relative accuracy within a few seconds.

  12. The ideal ear position in Caucasian females.

    PubMed

    Broer, P Niclas; Thiha, Aung; Ehrl, Denis; Sinno, Sammy; Juran, Sabrina; Szpalski, Caroline; Ng, Reuben; Ninkovic, Milomir; Prantl, Lukas; Heidekrueger, Paul I

    2018-03-01

    Ear position contributes significantly to facial appearance. However, while objective measurements remain the foundation for esthetic evaluations, little is known about how an ear should ideally be positioned regarding its rotational axis. This study aimed to further evaluate whether there exists a universally applicable ideal ear axis, and how sociodemographic factors impact such preferences. An interactive online survey was designed, enabling participants to change the axis of a female model's ear in terms of its forward and backward rotation. The questionnaire was sent out internationally to plastic surgeons and the general public. Demographic data were collected and analysis of variance was used to investigate respective preferences. A total of 1016 responses from 35 different countries (response rate: 18.5%) were gathered. Overall, 60% of survey takers chose the minus 10 or 5° angles to be most attractive. Significant differences were found regarding sex, ethnicity, country of residence, profession and respective ear axis preferences. Across multiple countries and ethnicities, an ear position in slight reclination of minus 5-10° is considered most pleasing in Caucasian females. However, sociodemographic factors significantly impact individual ear axis preferences and should be taken into consideration when performing reconstructive ear surgery. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Virtual reality training for improving the skills needed for performing surgery of the ear, nose or throat.

    PubMed

    Piromchai, Patorn; Avery, Alex; Laopaiboon, Malinee; Kennedy, Gregor; O'Leary, Stephen

    2015-09-09

    Virtual reality simulation uses computer-generated imagery to present a simulated training environment for learners. This review seeks to examine whether there is evidence to support the introduction of virtual reality surgical simulation into ear, nose and throat surgical training programmes. 1. To assess whether surgeons undertaking virtual reality simulation-based training achieve surgical ('patient') outcomes that are at least as good as, or better than, those achieved through conventional training methods.2. To assess whether there is evidence from either the operating theatre, or from controlled (simulation centre-based) environments, that virtual reality-based surgical training leads to surgical skills that are comparable to, or better than, those achieved through conventional training. The Cochrane Ear, Nose and Throat Disorders Group (CENTDG) Trials Search Co-ordinator searched the CENTDG Trials Register; Central Register of Controlled Trials (CENTRAL 2015, Issue 6); PubMed; EMBASE; ERIC; CINAHL; Web of Science; ClinicalTrials.gov; ICTRP and additional sources for published and unpublished trials. The date of the search was 27 July 2015. We included all randomised controlled trials and controlled trials comparing virtual reality training and any other method of training in ear, nose or throat surgery. We used the standard methodological procedures expected by The Cochrane Collaboration. We evaluated both technical and non-technical aspects of skill competency. We included nine studies involving 210 participants. Out of these, four studies (involving 61 residents) assessed technical skills in the operating theatre (primary outcomes). Five studies (comprising 149 residents and medical students) assessed technical skills in controlled environments (secondary outcomes). The majority of the trials were at high risk of bias. We assessed the GRADE quality of evidence for most outcomes across studies as 'low'. Operating theatre environment (primary outcomes) In

  14. Thumb carpometacarpal joint resurfacing with autologous ear cartilage.

    PubMed

    Nickell, William B

    2014-05-01

    A study was designed to ascertain the long-term effectiveness of using autologous full-thickness ear cartilage to resurface the arthritic face of the trapezium, leaving the body of the trapezium intact. The value of injection of the involved carpometacarpal (CMC) joint with local anesthetic in predicting improvement from the surgery was also studied. An operation was used to enter the CMC joint of the thumb between the thenar muscles and the abductor tendon. The articular surface of the trapezium was resected and resurfaced with full-thickness ear cartilage from the patient's ear. Patients were selected based on constant, unremitting pain. All patients also had x-ray evidence of severe arthritis at the CMC joint of the thumb. Both thumbs were evaluated for pain, range of motion, key and palmar pinch, and grip strength before the surgery and followed up for a minimum of 30 months to be included in the study. Fifty-nine patients had ear cartilage arthroplasty from 1997 to 2007 by the same surgeon with a total of 67 operations (8 patients, all women, had both thumbs operated). Forty-nine of these patients, 4 men and 45 women (53 hands), were available for follow-up and constitute the study group. Eight procedures were done on the left hand, and 45, on the right. There were no ear complications and no cartilage extrusions. All patients had improved range of motion and greatly decreased pain. Strength was equaled or exceeded the unoperated thumb. Preoperative joint injection was a good predictor of postoperative pain relief. All patients were pleased with the result and said that they would have the surgery again. Thumb CMC joint arthroplasty with autologous ear cartilage and preservation of the body of the trapezium is an effective alternative to existing procedures.There is no morbidity to the ear, and predictable long-term improvement in thumb pain and strength can be obtained. Injection of the CMC joint before surgery with local anesthetic is a reliable predictor of

  15. Comparison of the efficacy of propofol and metoclopramide in preventing postoperative nausea and vomiting after middle ear surgery.

    PubMed

    Unal, Yusuf; Ozsoylar, Ozgür; Arslan, Mustafa; Sarigüney, Damla; Akçabay, Mehmet

    2009-06-01

    To compare the administration of sub hypnotic dose of propofol with metoclopramide and placebo in prevention of postoperative nausea and vomiting (PONV) after middle ear surgery. This clinical research was performed in the Faculty of Medicine, Gazi University, Besevler, Ankara, Turkey, between December 2004 and October 2005. Following approval by the hospital ethics committee, 60 adult patients scheduled for a middle ear operation were randomly assigned into 3 groups. The patients in group P received 0.5 mg x kg(-1) propofol; in group M, 0.2 mg x kg(-1) metoclopramide, and in group C, 0.9% saline solution. The number of patients suffering from nausea and vomiting at 0-4, 4-12, and 12-24 hours postoperatively, and additional use of antiemetics was recorded. Comparisons of the data showed that at 0-4th hours, the incidence of vomiting was 25% in group P, 40% in group M, and 75% in group C. The incidence rate of group P was significantly lower than that of group C (p=0.002), and the rate of antiemetics use in group C was higher than that in group P (p=0.028). The Nausea Vomiting Scale scores of group C were also significantly higher than those of group P (p=0.005). There were no significant differences between the values at 4-12 and 12-24 hours. The administration of a sub hypnotic dose of propofol at the end of surgery was found to be at least as effective as metoclopramide in preventing PONV in the early postoperative period in adult patients undergoing middle ear surgery.

  16. Implants for reconstructive surgery of the nose and ears

    PubMed Central

    Berghaus, Alexander

    2008-01-01

    Implants shorten reconstruction, reduce trauma for the patients, are, in principle, of unlimited availability and can be given definable qualities that outnumber those of biological transplants. Lots of sometimes exotic materials have already been suggested for facial surgery and most of them have turned out to be unsuitable in the short or long term, because they did not satisfactorily fulfil the requirements of a “perfect implant”. However, transplants obviously cannot be regarded as ideal either because they often involve the necessity of a second intervention for removal, they are only available to a limited extent and some are at risk of postoperative deflection, shrinkage and absorption. This article is concerned with current knowledge about implant materials for rhinoplasty and ear reconstruction. Autogenous transplants will also be briefly discussed. The repetition of known facts should be largely avoided. In relation to this reference will be made to earlier papers [1]. PMID:22073082

  17. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  18. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  19. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  20. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  1. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  2. [Plastic surgery to correct deformities of the ear].

    PubMed

    Naumann, A

    2005-08-18

    For the plastic-surgical correction of mild deformities of the ears, well-proven incisional and suturing techniques are available. Only in exceptional cases is skin grafting or the use of cartilage ersatz material required. In the plastic surgical treatment of moderate to severe ear deformities, in contrast, not only incisional and suturing techniques, but also free skin grafts and ersatz materials are needed. At the ENT Department of the Ludwig-Maximilian University in Munich, plastic reconstruction of moderate to severe deformities of the external ear using porous polyethylene implants instead of rib cartilage grafts has been practiced with success for the past two years or so. Porous polyethylene implants provide good results and may help to avoid pre- and postoperative morbidity at donor site defects.

  3. Vestibular sensory functional status of cochlear implanted ears versus non-implanted ears in bilateral profound deaf adults.

    PubMed

    Cozma, Romică Sebastian; Dima-Cozma, Lucia Corina; Rădulescu, Luminiţa Mihaela; Hera, Maria Cristina; Mârţu, Cristian; Olariu, Raluca; Cobzeanu, Bogdan Mihail; Bitere, Oana Roxana; Cobzeanu, Mihail Dan

    2018-01-01

    Patients with hearing loss who underwent cochlear implantation can present symptomatic or asymptomatic vestibular damages earlier or later after the surgery. The vestibular permanent lesions could be acute, produced by surgical trauma or could be progressive due to local morphological changes made by the presence of the portelectrode in the inner ear (fibrosis related, ossification, basilar membrane distortion, endolymphatic hydrops). Besides histopathological findings in inner ear of cochlear implanted patients, the vestibular permanent damages could be found by assessment of clinical vestibular status. This study reports the sensorial vestibular functional findings for adults in cochlear implanted ears related to the electrode insertion type (cochleostomy or round window approach) and comparing to non-implanted deaf ears. A total of 20 adult patients with 32 cochlear implanted ears (12 patients with binaural cochlear implant and eight with monoaural) were selected for postoperatory vestibular examination by cervical and ocular vestibular myogenic potentials and vestibular caloric tests. The same tests were made for a control group of 22 non-implanted deaf ears. Functional testing results were reported related to the electrode insertion approach. For the cochleostomy group, we found different deficits: in 40% for saccular function, 44% for utricular function, and 12% horizontal canal dysfunction. In round window group, the deficit was present in 14.29% for saccular function, 28.57% for utricular function, and 28.58% for horizontal canal. In 46.88% of implanted ears, the vestibular function was completely preserved on all tested sensors. In conclusion, the vestibular functional status after inner ear surgery presents sensorial damages in 53.12% ears compare with the vestibular dysfunction existing in 50% of deaf non-operated ears. Round window insertion allows for better conservation of the vestibular function.

  4. A new tool for testing ossicular mobility during middle ear surgery: preliminary report of four cases.

    PubMed

    Hato, Naohito; Kohno, Hisashi; Okada, Masahiro; Hakuba, Nobuhiro; Gyo, Kiyofumi; Iwakura, Takashi; Tateno, Makoto

    2006-08-01

    We developed an ossicular vibration tester for the objective and quantitative assessment of ossicular mobility, which is one of the most critical factors affecting postoperative hearing after tympanoplasty. Our device consists of three components: a probe shaft with a curved tip to be attached to the target ossicle, a vibration exciter to activate the probe, and a piezoelectric sensor to detect vibrations of the probe. These components are encased in a stainless steel holder, allowing easy hand manipulation during ear surgery. The probe is activated with an electric signal at around 1,600 Hz. The system is controlled with a laptop computer, and the results are presented as the ratio of the ossicular resistance (ROR) to a reference value as a percentage. One measurement takes 10 ms. The device was applied in four selected patients during ear surgery. Several measurements in two of the cochlear implantees showed a greater difference in the RORs of the stapes (15-20% in Case 1 and 35-45% in Case 2), whereas the RORs of the malleus and incus were within the same range. This was thought to correspond to the partial cochlear calcification noted in Case 2. In Case 3, who underwent surgery because of otosclerosis, the ROR of the stapes was high, ranging from 70 to 80%. When measured for the malleus-incus fixation anomaly (Case 4), the ROR of the malleus and incus was in the range of 60 to 70%. Owing to the limited surgical view, the ROR of the stapes could not be measured. No problems related to the measurements with this device were noted. The design, principles, measuring procedures, and preliminary results of our new tool for testing ossicular mobility are reported. Measuring the ossicular mobility during surgery may provide important information for deciding the surgical procedures.

  5. [The effect of OSAHS on middle ear and inner ear vestibule function advances].

    PubMed

    Li, K L; Li, J R

    2016-05-20

    Obstructive sleep apnea hypopnea syndrome(OSAHS) as a common frequentlyoccurring disease, it can cause repeated episodes of hypoxaemia and hypercapnia during sleep. With long period of hypoxaemia, obvious pathological changes and dysfunction emerged in heart,brain and lung then all kinds of clinical symptoms appear. Because of the middle ear and inner ear themselves anatomical characteristics and blood supply of regulating mechanism, they often has been damaged before the other important organ damage. As scholars have indepth study of the auditory system complications in patients with OSAHS, various influence of OSAHS on the middle ear,inner ear also gradually be known.This paper will review the effect of OSAHS on middle ear, inner ear and vestibule function, hope to have some application value for clinical work. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  6. Surgical anatomy and pathology of the middle ear.

    PubMed

    Luers, Jan Christoffer; Hüttenbrink, Karl-Bernd

    2016-02-01

    Middle ear surgery is strongly influenced by anatomical and functional characteristics of the middle ear. The complex anatomy means a challenge for the otosurgeon who moves between preservation or improvement of highly important functions (hearing, balance, facial motion) and eradication of diseases. Of these, perforations of the tympanic membrane, chronic otitis media, tympanosclerosis and cholesteatoma are encountered most often in clinical practice. Modern techniques for reconstruction of the ossicular chain aim for best possible hearing improvement using delicate alloplastic titanium prostheses, but a number of prosthesis-unrelated factors work against this intent. Surgery is always individualized to the case and there is no one-fits-all strategy. Above all, both middle ear diseases and surgery can be associated with a number of complications; the most important ones being hearing deterioration or deafness, dizziness, facial palsy and life-threatening intracranial complications. To minimize risks, a solid knowledge of and respect for neurootologic structures is essential for an otosurgeon who must train him- or herself intensively on temporal bones before performing surgery on a patient. © 2015 Anatomical Society.

  7. Redefinition of the helical rim in cauliflower-ear surgery.

    PubMed

    Schonauer, F; La Rusca, I; Pereira, J A; Molea, G

    2002-01-01

    Cauliflower ear is a serious deformity of the auricle induced by single or repeated injury to the external ear. Few papers deal with surgical techniques for correcting this deformity. We describe the use of ipsilateral excess cartilage to restore the helical rim. Copyright 2002 The British Association of Plastic Surgeons.

  8. Endoscopy-Assisted Ear Surgery for Treatment of Chronic Otitis Media With Cholesteatoma, Adhesion, or Retraction Pockets.

    PubMed

    Ulku, Cagatay Han

    2017-06-01

    The objective of this study was to analyze the results of endoscopy-assisted ear surgery for the treatment of chronic otitis media with cholesteatoma, adhesion, or retraction pockets.Fifty-one patients who underwent oto-endoscopy-assisted canal wall up tympanomastoid surgery and/or limited anterior atticotomy with tympanoplasty for chronic otitis media with cholesteatoma, adhesion, or retraction pocket from 2006 to 2013 have been included in this study. Eradication of the disease from the middle ear and mastoid air cells was achieved by combination of the oto-microscobic and oto-endoscopic approaches. Second look surgery was performed 18 months later from the initial surgery in selected patients. Age, gender, pre-/postoperative otoscopy findings/audiograms, type of the used prostheses, and follow-up time were obtained from the patient's file. Anatomic integrity rates of the tympanic membrane, the mean gains of air bone gap, on pure-tone audiogram at 4 frequencies and existence of the residual disease were reviewed parameters. Functional evaluation was made in patients with intact tympanic membrane.Of the 51 patients, the ratios of the chronic otitis media with cholesteatoma and isolated adhesive otitis or retraction pocket cases were 74.5% (38/51) and 25.5% (13/51), respectively. Ossicular chain reconstruction was made with PORP in 27 patients and TORP in 20 patients, whereas the ossicular chain was intact in 4 patients. Anatomic integrity rates of the tympanic membrane were 90.2% (46/51). The overall (n = 46) pre-/postoperative mean ABG obtained at 4 frequencies were 28.3 ± 12.26 and 9.18 ± 5.68 dB (P < 0.0001) respectively. Residual cholesteatoma rate was 10.5% (34/38) for chronic otitis media with cholesteatoma patients. However, there was no recurrence or new cholesteatoma formation in isolated retraction pockets or adhesive otitis patients.Oto-endoscopic eradication of the cholesteatoma or epithelial tissue from hidden area after the all

  9. Surgical simulators in cataract surgery training.

    PubMed

    Sikder, Shameema; Tuwairqi, Khaled; Al-Kahtani, Eman; Myers, William G; Banerjee, Pat

    2014-02-01

    Virtual simulators have been widely implemented in medical and surgical training, including ophthalmology. The increasing number of published articles in this field mandates a review of the available results to assess current technology and explore future opportunities. A PubMed search was conducted and a total of 10 articles were reviewed. Virtual simulators have shown construct validity in many modules, successfully differentiating user experience levels during simulated phacoemulsification surgery. Simulators have also shown improvements in wet-lab performance. The implementation of simulators in the residency training has been associated with a decrease in cataract surgery complication rates. Virtual reality simulators are an effective tool in measuring performance and differentiating trainee skill level. Additionally, they may be useful in improving surgical skill and patient outcomes in cataract surgery. Future opportunities rely on taking advantage of technical improvements in simulators for education and research.

  10. Simulation in laparoscopic surgery.

    PubMed

    León Ferrufino, Felipe; Varas Cohen, Julián; Buckel Schaffner, Erwin; Crovari Eulufi, Fernando; Pimentel Müller, Fernando; Martínez Castillo, Jorge; Jarufe Cassis, Nicolás; Boza Wilson, Camilo

    2015-01-01

    Nowadays surgical trainees are faced with a more reduced surgical practice, due to legal limitations and work hourly constraints. Also, currently surgeons are expected to dominate more complex techniques such as laparoscopy. Simulation emerges as a complementary learning tool in laparoscopic surgery, by training in a safe, controlled and standardized environment, without jeopardizing patient' safety. Simulation' objective is that the skills acquired should be transferred to the operating room, allowing reduction of learning curves. The use of simulation has increased worldwide, becoming an important tool in different surgical residency programs and laparoscopic training courses. For several countries, the approval of these training courses are a prerequisite for the acquisition of surgeon title certifications. This article reviews the most important aspects of simulation in laparoscopic surgery, including the most used simulators and training programs, as well as the learning methodologies and the different key ways to assess learning in simulation. Copyright © 2013 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. 3D finite element model of the chinchilla ear for characterizing middle ear functions

    PubMed Central

    Wang, Xuelin; Gan, Rong Z.

    2016-01-01

    Chinchilla is a commonly used animal model for research of sound transmission through the ear. Experimental measurements of the middle ear transfer function in chinchillas have shown that the middle ear cavity greatly affects the tympanic membrane (TM) and stapes footplate (FP) displacements. However, there is no finite element (FE) model of the chinchilla ear available in the literature to characterize the middle ear functions with the anatomical features of the chinchilla ear. This paper reports a recently completed 3D FE model of the chinchilla ear based on X-ray micro-computed tomography images of a chinchilla bulla. The model consisted of the ear canal, TM, middle ear ossicles and suspensory ligaments, and the middle ear cavity. Two boundary conditions of the middle ear cavity wall were simulated in the model as the rigid structure and the partially flexible surface, and the acoustic-mechanical coupled analysis was conducted with these two conditions to characterize the middle ear function. The model results were compared with experimental measurements reported in the literature including the TM and FP displacements and the middle ear input admittance in chinchilla ear. An application of this model was presented to identify the acoustic role of the middle ear septa - a unique feature of chinchilla middle ear cavity. This study provides the first 3D FE model of the chinchilla ear for characterizing the middle ear functions through the acoustic-mechanical coupled FE analysis. PMID:26785845

  12. [Evaluation of postoperative pain intensity after ear, nose, and throat surgery--the effect of intraoperative fentanyl use].

    PubMed

    Mizota, Toshiyuki; Suzuki, Haruyo; Daijo, Hiroki; Tanaka, Tomoharu; Fukuda, Kazuhiko

    2014-11-01

    This study was designed to determine postoperative pain levels after ear, nose, and throat (ENT) surgery, and also to examine whether intraoperative fentanyl use during ENT surgery enhances the quality of postoperative pain control. The distribution of pain scores and rescue analgesic requirements among 198 patients undergoing ENT surgery were examined. Multivariate logistic regression analysis was performed to identify independent factors associated with moderate to severe postoperative pain (maximal pain score ≥ 5 on the numerical rating scale) and postoperative nausea and vomiting (PONV). 27.8% of patients experienced moderate to severe postoperative pain after ENT surgery. The distribution of postoperative pain levels was similar among procedures performed on different anatomical regions. Intraoperative fentanyl use was not associated with moderate to severe postoperative pain (adjusted odds ratio (95% confidence interval) :1.03 (0.51-2.13))]. On the other hand, intraoperative fentanyl use was independently associated with PONV [3.10 (1.25-8.92); P = 0.0138]. Prevalence of moderate to severe postoperative pain after ENT surgery was approximately 28%. Intraoperative fentanyl use was not associated with a decreased incidence of moderate to severe postoperative pain, but was significantly associated with PONV.

  13. Gain affected by the interior shape of the ear canal.

    PubMed

    Yu, Jen-Fang; Chen, Yen-Sheng; Cheng, Wei-De

    2011-06-01

    This study investigated the correlation of gain distribution and the interior shape of the human external ear canal. Cross-sectional study of gain measurement at the first bend and second bend. Chang Gung Memorial Hospital and Chang Gung University. There were 15 ears in patients aged between 20 and 30 years (8 men/7 women) with normal hearing and middle ears. Stimulus frequencies of 500, 1000, 2000, 3000, and 4000 Hz were based on the standard clinical hearing test. Measurements closer to the tympanic membrane and the positions at the first and second bends were confirmed by using otoscope. Real ear measurement to analyze the canal resonance in human external ears was adopted. This study found that gain at stimulus frequencies of 4000 Hz was affected by the interior shape of the ear canal (P < .005), particularly at the first and second bends, whereas gain was only affected by the length of the ear canal for stimulus frequencies of 2000 Hz (P < .005). This study found that gain was affected not only by the length of the external auditory canal (EAC) but also by the interior shape of the EAC significantly. The findings of this study may have potential clinical applications in canalplasty and congenital aural atresia surgery and may be used to guide surgeries that attempt to reshape the ear canal to achieve more desirable hearing outcomes.

  14. Ear, nose and throat day-case surgery at a district general hospital.

    PubMed

    Pézier, T; Stimpson, P; Kanegaonkar, R G; Bowdler, D A

    2009-03-01

    In 2000, The NHS Plan in the UK set a target of 75% for all surgical activity to be performed as day-cases. We aim to assess day-case turnover for ENT procedures and, in particular, day-case rates for adult and paediatric otological procedures together with re-admissions within 72 h as a proxy measure of safety. Retrospective collection of data (procedure and length of stay) from the computerised theatre system (Galaxy) and Patient Information Management System (PIMS) of all elective patients operated over one calendar year. The setting was a district general hospital ENT department in South East England. All ENT operations are performed with the exception of oncological head and neck procedures and complex skull-base surgery. Overall, 2538 elective operations were performed during the study period. A total of 1535 elective adult procedures were performed with 74% (1137 of 1535) performed as day-cases. Of 1003 paediatric operations, 73% (730 of 1003) were day-cases. Concerning otological procedures, 93.4% (311 of 333) of paediatric procedures were day-cases. For adults, we divided the procedures into major and minor, achieving day-case rates of 88% (93 of 101) and 91% (85 of 93), respectively. The overall day-case rate for otological procedures was 91% (528 of 580). Re-admission rates overall were 0.7% (11 of 1535) for adults and 0.9% (9 of 1003) for paediatric procedures. The most common procedure for re-admission was tonsillectomy accounting for 56% of all adult re-admissions and 78% of paediatric re-admissions. The were no deaths following day-case procedures. ENT surgery is well-suited to a day-case approach. UK Government targets are attainable when considering routine ENT surgery. Day-case rates for otology in excess of targets are possible even when considering major ear surgery.

  15. Desmoplastic small round cell tumor of the middle ear: A case report.

    PubMed

    Xu, Jing; Yao, Mengwei; Yang, Xinxin; Liu, Tao; Wang, Shaohua; Ma, Dengdian; Li, Xiaoyu

    2018-04-01

    Desmoplastic small round cell tumor (DSRCT) is a rare, aggressive and malignant tumor. This report describes a case involving DSRCT of the middle ear which no case has been reported in the literature till date. A 59-year-old Chinese man with a 40-year history of repeated suppuration of his right ear and 1-year history of drooping of the angle of mouth. The CT of the middle ear and brain scan and enhanced MRI showed space occupying lesion in the right middle ear. Desmoplastic small round cell tumor of the middle ear. After relevant examinations, radical mastoidectomy and subtotal temporal bone resection were performed on the right ear under general anesthesia. The patient underwent postoperative adjuvant chemoradiation therapy. The patient was counterchecked regularly,there was norecurrence of DSRCT of the middle ear. Four years after surgery, the CT and MRI of the middle ear mastoid showed right middle ear soft tissue shadow,but postoperative pathological results showed proliferative fibrous and vascular tissues with chronic inflammatory cell infiltration and necrosis. DSRCT is a relatively aggressive, malignant mesenchymal tumor, with a very poor prognosis.The diagnosis of DSRCT relies on immunohistological data. Early diagnosis, radical surgery, chemotherapy, and radiotherapy are considered a reasonable way to prolong survival.

  16. Piercing the upper ear: a simple infection, a difficult reconstruction.

    PubMed

    Cicchetti, S; Skillman, J; Gault, D T

    2002-04-01

    Piercing the upper ear to retain jewellery is now commonplace. When infection ensues, devastating chondritis leads to collapse of the ear. To our knowledge, the surgical reconstruction of post-piercing deformities has not been documented in the literature. We present five such cases referred for autogenous-tissue ear reconstruction. In four of these, the destroyed segments of ear cartilage were replaced with a carved costal-cartilage framework. One patient declined surgery. The importance of preventing infection is stressed. Copyright 2002 The British Association of Plastic Surgeons.

  17. A New Intraoperative Real-time Monitoring System for Reconstructive Middle Ear Surgery: An Experimental and Clinical Feasibility Study.

    PubMed

    Zahnert, Thomas; Metasch, Marie-Luise; Seidler, Hannes; Bornitz, Matthias; Lasurashvili, Nicoloz; Neudert, Marcus

    2016-12-01

    Electromagnetical excitation of ossicular vibration is suitable for middle ear transmission measurements in the experimental and clinical setting. Thereby, it can be used as a real-time monitoring system for quality control in ossiculoplasty. Positioning and coupling of middle ear prosthesis are a precondition for good postoperative hearing results, but at the same time completely dependent upon the surgeon's subjective judgment during surgery. We evaluated an electromagnetically driven measurement system that enables for in vitro and in vivo transmission measurements and thus can be used as a real-time monitoring tool in ossicular reconstruction. For electromagnetical excitation a magnet was placed on the umbo of the malleus handle and driven by a magnetic field. The induced stapes displacement was picked up by laser Doppler vibrometry on the footplate. Measurements were performed on the intact ossicular chain in five cadaveric temporal bones and during five cochlear implant surgeries. Additionally, two ossiculoplasties were performed under real-time transmission feedback with the monitoring system. Experimentally, the equivalent sound pressure level of the electromagnetic excitation was about 70 to 80 dB which is 10 to 20 dB less than the acoustic stimulation. In the intraoperative setup the generated stapes displacements were about 5 to 20 dB smaller compared with the temporal bone experiments. Applied as real-time feedback system, an improvement in the middle ear transfer function of 4.5 dB in total and 20 dB in partial ossicular reconstruction were achieved. The electromagnetical excitation and measurement system is comparable to the gold standard with acoustical stimulation in both, the experimental setup in temporal bones as well as in vivo. The technical feasibility of the electromagnetical excitation method has been proven and it is shown that it can be used as a real-time monitoring system for ossiculoplasty in the operation room.

  18. Precise individualized armature for ear reconstruction

    NASA Astrophysics Data System (ADS)

    Evenhouse, Raymond J.; Chen, Xiaoming

    1991-04-01

    The cosmetic result of an ear restored surgically or via prosthetics is dependent on the surgeon''s ability to carve a precise cartilage armature at the time of surgery or the prosthetist''s ability to sculpt in wax an exact duplicate of the patient''s " missing" ear. Introducing CAD/CAM technology into the process benefits the esthetic outcome of these procedures. By utilizing serial section information derived from CAT MRI or moulage techniques a mirrorimage of the patient''s " donor" ear is generated. The resulting earform data is then used for the design of a cartilage armature produced by multi-axis milling or to produce by stereolithography a model which serves as the basis for a prosthesis.

  19. Learning to perform ear reconstruction.

    PubMed

    Wilkes, Gordon H

    2009-08-01

    Learning how to perform ear reconstruction is very difficult. There are no standardized teaching methods. This has resulted in many ear reconstructions being suboptimal. Learning requires a major commitment by the surgeon. Factors to be seriously considered by those considering performing this surgery are (1) commitment, (2) aptitude, (3) training methods available, (4) surgical skills and experience, and (5) additional equipment needs. Unless all these factors are addressed in a surgeon's decision to perform this form of reconstruction, the end result will be compromised, and patient care will not be optimized. It is hoped that considering these factors and following this approach will result in a higher quality of aesthetic result. The future of ear reconstruction lies in the use of advanced digital technologies and tissue engineering. Copyright Thieme Medical Publishers.

  20. [Lop ear - knife, tape, or nothing at all?].

    PubMed

    Klockars, Tuomas

    2013-01-01

    More than 200 different surgical techniques of correction of lop ear have been published. The operation is usually recommended to be performed at the age of six years or after. In addition, lop ear surgery involves risks, the most common complications being bleeding, infections, sensory alterations and scarring problems. Surgical preference and decision should always be based on realistic expectations of the patient or the parents, and prior to the decision they should have adequate information about the nature of the procedure and potential complications. Splint therapy of lop ear is possible for infants.

  1. 21 CFR 344.52 - Labeling of ear drying aid drug products.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., and Cosmetic Act (the act) relating to misbranding and the prohibition in section 301(d) of the act... in the ear [bullet] had ear surgery [bullet] dizziness.” (4) “Stop use and ask a doctor if [in bold...

  2. 21 CFR 344.52 - Labeling of ear drying aid drug products.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., and Cosmetic Act (the act) relating to misbranding and the prohibition in section 301(d) of the act... in the ear [bullet] had ear surgery [bullet] dizziness.” (4) “Stop use and ask a doctor if [in bold...

  3. 21 CFR 344.52 - Labeling of ear drying aid drug products.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., and Cosmetic Act (the act) relating to misbranding and the prohibition in section 301(d) of the act... in the ear [bullet] had ear surgery [bullet] dizziness.” (4) “Stop use and ask a doctor if [in bold...

  4. Intraear Compensation of Field Corn, Zea mays, from Simulated and Naturally Occurring Injury by Ear-Feeding Larvae.

    PubMed

    Steckel, S; Stewart, S D

    2015-06-01

    Ear-feeding larvae, such as corn earworm, Helicoverpa zea Boddie (Lepidoptera: Noctuidae), can be important insect pests of field corn, Zea mays L., by feeding on kernels. Recently introduced, stacked Bacillus thuringiensis (Bt) traits provide improved protection from ear-feeding larvae. Thus, our objective was to evaluate how injury to kernels in the ear tip might affect yield when this injury was inflicted at the blister and milk stages. In 2010, simulated corn earworm injury reduced total kernel weight (i.e., yield) at both the blister and milk stage. In 2011, injury to ear tips at the milk stage affected total kernel weight. No differences in total kernel weight were found in 2013, regardless of when or how much injury was inflicted. Our data suggested that kernels within the same ear could compensate for injury to ear tips by increasing in size, but this increase was not always statistically significant or sufficient to overcome high levels of kernel injury. For naturally occurring injury observed on multiple corn hybrids during 2011 and 2012, our analyses showed either no or a minimal relationship between number of kernels injured by ear-feeding larvae and the total number of kernels per ear, total kernel weight, or the size of individual kernels. The results indicate that intraear compensation for kernel injury to ear tips can occur under at least some conditions. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Simulation-based training for prostate surgery.

    PubMed

    Khan, Raheej; Aydin, Abdullatif; Khan, Muhammad Shamim; Dasgupta, Prokar; Ahmed, Kamran

    2015-10-01

    To identify and review the currently available simulators for prostate surgery and to explore the evidence supporting their validity for training purposes. A review of the literature between 1999 and 2014 was performed. The search terms included a combination of urology, prostate surgery, robotic prostatectomy, laparoscopic prostatectomy, transurethral resection of the prostate (TURP), simulation, virtual reality, animal model, human cadavers, training, assessment, technical skills, validation and learning curves. Furthermore, relevant abstracts from the American Urological Association, European Association of Urology, British Association of Urological Surgeons and World Congress of Endourology meetings, between 1999 and 2013, were included. Only studies related to prostate surgery simulators were included; studies regarding other urological simulators were excluded. A total of 22 studies that carried out a validation study were identified. Five validated models and/or simulators were identified for TURP, one for photoselective vaporisation of the prostate, two for holmium enucleation of the prostate, three for laparoscopic radical prostatectomy (LRP) and four for robot-assisted surgery. Of the TURP simulators, all five have demonstrated content validity, three face validity and four construct validity. The GreenLight laser simulator has demonstrated face, content and construct validities. The Kansai HoLEP Simulator has demonstrated face and content validity whilst the UroSim HoLEP Simulator has demonstrated face, content and construct validity. All three animal models for LRP have been shown to have construct validity whilst the chicken skin model was also content valid. Only two robotic simulators were identified with relevance to robot-assisted laparoscopic prostatectomy, both of which demonstrated construct validity. A wide range of different simulators are available for prostate surgery, including synthetic bench models, virtual-reality platforms, animal

  6. Cartilage island on stapes: autologous PORP in the hypoventilated middle ear.

    PubMed

    Hess-Erga, Jeanette; Engelen, Bart Lambertus Henricus Jozef; Vassbotn, Flemming Slinning

    2017-04-01

    The most common technique in sound restoration of the middle ear is prosthetic surgery. Hypoventilation of the middle ear may cause adhesive otitis or atelectasis resulting in a higher risk of prosthetic extrusion rate and recurrence of the underlying cholesteatoma. We report long-term results using an island of tragal cartilage as an autologous PORP in selected patients with poor middle ear ventilation. Retrospective chart reviews were performed for procedures involving 52 patients between year 2000 and 2009. All patients that underwent surgery using tragal cartilage interposed between the suprastructure of the stapes and the tympanic membrane were included in this study. Audiological parameters using four frequencies, 0.5, 1, 2 and 3 kHz, according to AAO-HNS guidelines, were assessed pre-and postoperatively. The hearing results on different PTA frequencies were also investigated. We report long-term follow-up of patients with hypoventilated middle ear with a success rate of 71% (ABG <20%). With regards to the ABG, the low frequency component (5 and 1 kHz) showed a significantly (p < 0.05) larger improvement of mean values after surgery as compared to the high-frequency component (2 and 3 kHz). Cartilage island PORP on stapes is a stable and efficient method for selected patients with chronic middle ear disease.

  7. Micro-endoscopic ear anatomy of guinea pig applied to experimental surgery.

    PubMed

    Barros, Bruno Borges de Carvalho; Andrade, José Santos Cruz de; Garcia, Leandro Borborema; Pifaia, Gustavo Ribeiro; Cruz, Oswaldo Laércio Mendonça; Onishi, Ektor Tsuneo; Penido, Norma de Oliveira

    2014-01-01

    To describe topographic and endoscopic anatomy of guinea pig ear for development of surgical approaches in experimental studies. Experimental study. Eight adult guinea pigs (Cavia porcellus) were used in this study. Four animals were described through endoscopic view and four animals were used to describe topographic anatomy. The main structures of middle ear were well identified through endoscopy view: oval and round window, ossicles and vascular structures. Temporal bone position, landmarks and its relations to skull are perceived with topographic description. Topographic anatomic description allowed exposition of temporal bone relations for external surgical approaches. Alternatively, grooves and middle ear structures were identified and may be used to transcanal accesses.

  8. Tele-surgery simulation with a patient organ model for robotic surgery training.

    PubMed

    Suzuki, S; Suzuki, N; Hattori, A; Hayashibe, M; Konishi, K; Kakeji, Y; Hashizume, M

    2005-12-01

    Robotic systems are increasingly being incorporated into general laparoscopic and thoracoscopic surgery to perform procedures such as cholecystectomy and prostatectomy. Robotic assisted surgery allows the surgeon to conduct minimally invasive surgery with increased accuracy and with potential benefits for patients. However, current robotic systems have their limitations. These include the narrow operative field of view, which can make instrument manipulation difficult. Current robotic applications are also tailored to specific surgical procedures. For these reasons, there is an increasing demand on surgeons to master the skills of instrument manipulation and their surgical application within a controlled environment. This study describes the development of a surgical simulator for training and mastering procedures performed with the da Vinci surgical system. The development of a tele-surgery simulator and the construction of a training center are also described, which will enable surgeons to simulate surgery from or in remote places, to collaborate over long distances, and for off-site expert assistance. Copyright 2005 John Wiley & Sons, Ltd.

  9. Development of the McGill simulator for endoscopic sinus surgery: a new high-fidelity virtual reality simulator for endoscopic sinus surgery.

    PubMed

    Varshney, Rickul; Frenkiel, Saul; Nguyen, Lily H P; Young, Meredith; Del Maestro, Rolando; Zeitouni, Anthony; Tewfik, Marc A

    2014-01-01

    The technical challenges of endoscopic sinus surgery (ESS) and the high risk of complications support the development of alternative modalities to train residents in these procedures. Virtual reality simulation is becoming a useful tool for training the skills necessary for minimally invasive surgery; however, there are currently no ESS virtual reality simulators available with valid evidence supporting their use in resident education. Our aim was to develop a new rhinology simulator, as well as to define potential performance metrics for trainee assessment. The McGill simulator for endoscopic sinus surgery (MSESS), a new sinus surgery virtual reality simulator with haptic feedback, was developed (a collaboration between the McGill University Department of Otolaryngology-Head and Neck Surgery, the Montreal Neurologic Institute Simulation Lab, and the National Research Council of Canada). A panel of experts in education, performance assessment, rhinology, and skull base surgery convened to identify core technical abilities that would need to be taught by the simulator, as well as performance metrics to be developed and captured. The MSESS allows the user to perform basic sinus surgery skills, such as an ethmoidectomy and sphenoidotomy, through the use of endoscopic tools in a virtual nasal model. The performance metrics were developed by an expert panel and include measurements of safety, quality, and efficiency of the procedure. The MSESS incorporates novel technological advancements to create a realistic platform for trainees. To our knowledge, this is the first simulator to combine novel tools such as the endonasal wash and elaborate anatomic deformity with advanced performance metrics for ESS.

  10. Finite element analysis of auditory characteristics in patients with middle ear diseases.

    PubMed

    Tu, Bo; Li, Xiaoping; Nie, Zhenhua; Shi, Changzheng; Li, Hengguo

    2017-07-01

    This study validates that a finite element model of the human ossicular chain and tympanic membrane can be used as an effective surgical assessment tool in clinics. The present study was performed to investigate the application of a finite element model of ossicular chain and tympanic membrane for fabrication of individualized artificial ossicles. Twenty patients (20 ears) who underwent surgery for middle ear disease (n = 20) and 10 healthy controls (10 ears) were enrolled in the hospital. Computed tomography (CT) and pure tone audiometry were performed before and after surgery. A finite element model was developed using CT scans, and correlation analysis was conducted between stapes displacement and surgical methods. An audiometric test was also performed for 14 patients before and after surgery. Stapes displacement in the healthy group (average = 3.31 × 10 -5  mm) was significantly greater than that in the impaired group (average = 1.41 × 10 -6 mm) prior to surgery. After surgery, the average displacement in the impaired group was 2.55 × 10 -6 mm, which represented a significant improvement. For the patients who underwent the audiometric test, 10 improved hearing after surgery, and stapes displacement increased in nine of these 10 patients.

  11. Virtual reality-assisted robotic surgery simulation.

    PubMed

    Albani, Justin M; Lee, David I

    2007-03-01

    For more than a decade, advancing computer technologies have allowed incorporation of virtual reality (VR) into surgical training. This has become especially important in training for laparoscopic procedures, which often are complex and leave little room for error. With the advent of robotic surgery and the development and prevalence of a commercial surgical system (da Vinci robot; Intuitive Surgical, Sunnyvale, CA), a valid VR-assisted robotic surgery simulator could minimize the steep learning curve associated with many of these complex procedures and thus enable better outcomes. To date, such simulation does not exist; however, several agencies and corporations are involved in making this dream a reality. We review the history and progress of VR simulation in surgical training, its promising applications in robotic-assisted surgery, and the remaining challenges to implementation.

  12. Fly-ear inspired acoustic sensors for gunshot localization

    NASA Astrophysics Data System (ADS)

    Liu, Haijun; Currano, Luke; Gee, Danny; Yang, Benjamin; Yu, Miao

    2009-05-01

    The supersensitive ears of the parasitoid fly Ormia ochracea have inspired researchers to develop bio-inspired directional microphone for sound localization. Although the fly ear is optimized for localizing the narrow-band calling song of crickets at 5 kHz, experiments and simulation have shown that it can amplify directional cues for a wide frequency range. In this article, a theoretical investigation is presented to study the use of fly-ear inspired directional microphones for gunshot localization. Using an equivalent 2-DOF model of the fly ear, the time responses of the fly ear structure to a typical shock wave are obtained and the associated time delay is estimated by using cross-correlation. Both near-field and far-field scenarios are considered. The simulation shows that the fly ear can greatly amplify the time delay by ~20 times, which indicates that with an interaural distance of only 1.2 mm the fly ear is able to generate a time delay comparable to that obtained by a conventional microphone pair with a separation as large as 24 mm. Since the parameters of the fly ear structure can also be tuned for muzzle blast and other impulse stimulus, fly-ear inspired acoustic sensors offers great potential for developing portable gunshot localization systems.

  13. Correction of Stahl ear deformity using a suture technique.

    PubMed

    Khan, Muhammad Adil Abbas; Jose, Rajive M; Ali, Syed Nadir; Yap, Lok Huei

    2010-09-01

    Correction of partial ear deformities can be a challenging task for the plastic surgeon. There are no standard techniques for correcting many of these deformities, and several different techniques are described in literature. Stahl ear is one such anomaly, characterized by an accessory third crus in the ear cartilage, giving rise to an irregular helical rim. The conventional techniques of correcting this deformity include either excision of the cartilage, repositioning of the cartilage, or scoring techniques. We recently encountered a case of Stahl ear deformity and undertook correction using internal sutures with very good results. The technical details of the surgery are described along with a review of literature on correcting similar anomalies.

  14. Cilia and Ear.

    PubMed

    Piatti, Gioia; De Santi, Maria Margherita; Torretta, Sara; Pignataro, Lorenzo; Soi, Daniela; Ambrosetti, Umberto

    2017-04-01

    To investigate the prevalence of otological complications derived from primary ciliary dyskinesia (PCD) in adulthood. Twenty-three patients with diagnosed PCD underwent medical history aimed at recording the presence of ear, nose, and throat manifestations (ENT) and any surgical treatments. The ENT objectivity was annotated, and then patients were subjected to audiometric test, tympanometry, registration of otoacoustic emission, and vestibular evaluation. Otitis media with chronic middle ear effusion (OME) during childhood was reported in 52% of the subjects, no patient had undergone ear surgery, and only 2 patients had an episode of otitis in the last year. Eleven of 23 patients showed normal hearing, 11 had a conductive hearing impairment, and 1 showed a severe sensorineural hearing loss unrelated to the syndrome. The bilateral stapedial reflex was only found in all cases of normoacusia and type A tympanogram, distortion product otoacoustic emissions (DPOAE) were present in 8 patients, and no patient had vestibular alterations. Our study confirms a very frequent prevalence of OME in PCD during childhood. Careful monitoring of otological complications of the syndrome is always desirable, also given the high presence in adults of other manifestations in the upper airways, such as chronic rhinosinusitis and nasal polyposis.

  15. Predicting skin deficits through surface area measurements in ear reconstruction and adult ear surface area norms.

    PubMed

    Yazar, Memet; Sevim, Kamuran Zeynep; Irmak, Fatih; Yazar, Sevgi Kurt; Yeşilada, Ayşin Karasoy; Karşidağğ, Semra Hacikerim; Tatlidede, Hamit Soner

    2013-07-01

    Ear reconstruction is one of the most challenging procedures in plastic surgery practice. Many studies and techniques have been described in the literature for carving a well-pronounced framework. However, just as important as the cartilage framework is the ample amount of delicate skin coverage of the framework. In this report, we introduce an innovative method of measuring the skin surface area of the auricle from a three-dimensional template created from the healthy ear.The study group consisted of 60 adult Turkish individuals who were randomly selected (30 men and 30 women). The participant ages ranged from 18 to 45 years (mean, 31.5 years), and they had no history of trauma or congenital anomalies. The template is created by dividing the ear into aesthetic subunits and using ImageJ software to estimate the necessary amount of total skin surface area required.Reconstruction of the auricle is a complicated process that requires experience and patience to provide the auricular details. We believe this estimate will shorten the learning curve for residents and surgeons interested in ear reconstruction and will help surgeons obtain adequate skin to drape over the well-sculpted cartilage frameworks by providing a reference list of total ear skin surface area measurements for Turkish men and women.

  16. A Longitudinal Study in Children With Sequential Bilateral Cochlear Implants: Time Course for the Second Implanted Ear and Bilateral Performance.

    PubMed

    Reeder, Ruth M; Firszt, Jill B; Cadieux, Jamie H; Strube, Michael J

    2017-01-01

    Whether, and if so when, a second-ear cochlear implant should be provided to older, unilaterally implanted children is an ongoing clinical question. This study evaluated rate of speech recognition progress for the second implanted ear and with bilateral cochlear implants in older sequentially implanted children and evaluated localization abilities. A prospective longitudinal study included 24 bilaterally implanted children (mean ear surgeries at 5.11 and 14.25 years). Test intervals were every 3-6 months through 24 months postbilateral. Test conditions were each ear and bilaterally for speech recognition and localization. Overall, the rate of progress for the second implanted ear was gradual. Improvements in quiet continued through the second year of bilateral use. Improvements in noise were more modest and leveled off during the second year. On all measures, results from the second ear were poorer than the first. Bilateral scores were better than either ear alone for all measures except sentences in quiet and localization. Older sequentially implanted children with several years between surgeries may obtain speech understanding in the second implanted ear; however, performance may be limited and rate of progress gradual. Continued contralateral ear hearing aid use and reduced time between surgeries may enhance outcomes.

  17. [Revisional radical mastoidectomy surgeries--25 cases'experience].

    PubMed

    Li, L; Xie, J; Liu, Y; Gong, S S

    2017-10-07

    Objective: To analyze the risk factors of failure to dry ear after radical mastoidectomy and discuss key points in revisonal surgery. Methods: Clinical data of 25 patients(32 ears) with revisonal mastoidectomy were analyzed. The preoperative temporal bone CT findings, intra-operative findings, surgical procedures, postoperative operating cavities and aural abilities were recorded and analyzed. Results: All patients received preoperative temporal bone CT followed by revisonal radical mastoidectomy under microscope and general anesthesia. Among the revisonal surgeries, 19 ears(59.4%) presented cholesteatoma and 13 ears(40.6%) had no cholesteatoma. In addition, the inadequate opening for mastoid cavity and incompleted removal of the pathological tissues accounted for 90.6%(29/32), the insufficient drainage of surgical cavity for 90.6%(29/32), the lesions in tympanic ostium of eustachian tube for 31.2%(10/32), the improper operation procedures and selection of incision for 15.6%(5/32). As for the re-operation of the modified canal wall down mastoidectomy, tympanoplasty(Ⅱ) plus plastic repairing of cavity of concha were performed in 14 ears(43.8%), the modified canal wall down mastoidectomy, tympanoplasty(Ⅱ) plus reconstruction posterior bony wall of ear canal in 2 ears(6.2%); the modified canal wall down mastoidectomy, tympanoplasty(Ⅲ) plus plastic repairing of cavity of concha in 10 eras(31.3%), the modified canal wall down mastoidectomy, tympanoplasty(Ⅲ) plus reconstruction posterior boney wall of ear canal in 1 ear(3.1%); the radical mastoidectomy plus plastic repairing of cavity of concha in 5 ears(15.6%). Lodoform gauzes were packed in surgical cavity for 2 weeks and the antibiotic was used for 3 days after surgery. All patients had dressing of ears and their ears were dropped with ofloxacin regularly. The dry ear time ranged from 4 to 8 weeks, the average point was the 5th week. During a period of 6-18 months for follow-up, all patients got dried ears

  18. Design and preliminary testing of a novel skin expander for total ear reconstruction in a rabbit model.

    PubMed

    Xiong, Wu; Yan, Yu; Hu, Feng; Liu, Can; Wang, Shaohua; Chen, Jia; Wang, Xueqi; Zhou, Jianda

    2016-01-01

    Ear reconstruction is one of the most complicated and challenging techniques in plastic surgery because of the histologic and anatomic properties of the ear. Success depends on fitting the auriform cartilage scaffold into the overlying skin, but current approaches can just give results that are not lifelike and can lead to complications. A novel double-capsule, double-valve plastic ear expander was designed and implanted subcutaneously on either side of the dorsum of six New Zealand white rabbits (two expanders per rabbit). The outer capsule was expanded by injecting approximately 120 mL of physiological saline, then withdrawing the liquid on two occasions. Next, the ear-shaped inner capsule was filled with high-hardness plaster, and the external capsule was emptied such that the expanded skin flap and external capsule responded to the negative pressure and closed over the ear-shaped inner capsule. As a result, the skin flap adopted an ear shape. The ear expander was left in place for 4 wk, removed with the help of a mini-incision, and stripped of its fibrous capsule. To simulate human ear reconstruction, the expander was replaced with an auriform silicone prosthesis, and the effects of auricular reconstruction were observed dynamically. All 12 skin flaps maintained abundant blood supply, created a clear outline of the ear framework, and produced a lifelike result. No complications were observed during the 4-wk observation period. The expanded skin flaps described here can mold to the desired contours and appear lifelike, as well as maintain abundant blood supply. This may provide a simpler approach to total ear reconstruction that reduces risk of complications. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Effectiveness of Ear Splint Therapy for Ear Deformities

    PubMed Central

    2017-01-01

    Objective To present our experience with ear splint therapy for babies with ear deformities, and thereby demonstrate that this therapy is an effective and safe intervention without significant complications. Methods This was a retrospective study of 54 babies (35 boys and 19 girls; 80 ears; age ≤3 months) with ear deformities who had received ear splint therapy at the Center for Torticollis, Department of Physical Medicine and Rehabilitation, Ajou University Hospital between December 2014 and February 2016. Before the initiation of ear splint therapy, ear deformities were classified with reference to the standard terminology. We compared the severity of ear deformity before and after ear splint therapy by using the physician's ratings. We also compared the physician's ratings and the caregiver's ratings on completion of ear splint therapy. Results Among these 54 babies, 41 children (58 ears, 72.5%) completed the ear splint therapy. The mean age at initiation of therapy was 52.91±18.26 days and the treatment duration was 44.27±32.06 days. Satyr ear, forward-facing ear lobe, Darwinian notch, overfolded ear, and cupped ear were the five most common ear deformities. At the completion of therapy, the final physician's ratings of ear deformities were significantly improved compared to the initial ratings (8.28±1.44 vs. 2.51±0.92; p<0.001). There was no significant difference between the physician's ratings and the caregiver's ratings at the completion of ear splint therapy (8.28±1.44 vs. 8.0±1.61; p=0.297). Conclusion We demonstrated that ear splint therapy significantly improved ear deformities in babies, as measured by quantitative rating scales. Ear splint therapy is an effective and safe intervention for babies with ear deformities. PMID:28289646

  20. Simulation training in video-assisted urologic surgery.

    PubMed

    Hoznek, András; Salomon, Laurent; de la Taille, Alexandre; Yiou, René; Vordos, Dimitrios; Larre, Stéphane; Abbou, Clément-Claude

    2006-03-01

    The current system of surgical education is facing many challenges in terms of time efficiency, costs, and patient safety. Training using simulation is an emerging area, mostly based on the experience of other high-risk professions like aviation. The goal of simulation-based training in surgery is to develop not only technical but team skills. This learning environment is stress-free and safe, allows standardization and tailoring of training, and also objectively evaluate performances. The development of simulation training is straightforward in endourology, since these procedures are video-assisted and the low degree of freedom of the instruments is easily replicated. On the other hand, these interventions necessitate a long learning curve, training in the operative room is especially costly and risky. Many models are already in use or under development in all fields of video-assisted urologic surgery: ureteroscopy, percutaneous surgery, transurethral resection of the prostate, and laparoscopy. Although bench models are essential, simulation increasingly benefits from the achievements and development of computer technology. Still in its infancy, virtual reality simulation will certainly belong to tomorrow's teaching tools.

  1. Animal models in plastic and reconstructive surgery simulation-a review.

    PubMed

    Loh, Charles Yuen Yung; Wang, Aline Yen Ling; Tiong, Vincent Tze Yang; Athanassopoulos, Thanassi; Loh, Meiling; Lim, Philip; Kao, Huang-Kai

    2018-01-01

    The use of live and cadaveric animal models in surgical training is well established as a means of teaching and improving surgical skill in a controlled setting. We aim to review, evaluate, and summarize the models published in the literature that are applicable to Plastic Surgery training. A PubMed search for keywords relating to animal models in Plastic Surgery and the associated procedures was conducted. Animal models that had cross over between specialties such as microsurgery with Neurosurgery and pinnaplasty with ear, nose, and throat surgery were included as they were deemed to be relevant to our training curriculum. A level of evidence and recommendation assessment was then given to each surgical model. Our review found animal models applicable to plastic surgery training in four major categories namely-microsurgery training, flap raising, facial surgery, and hand surgery. Twenty-four separate articles described various methods of practicing microsurgical techniques on different types of animals. Fourteen different articles each described various methods of conducting flap-based procedures which consisted of either local or perforator flap dissection. Eight articles described different models for practicing hand surgery techniques. Finally, eight articles described animal models that were used for head and neck procedures. A comprehensive summary of animal models related to plastic surgery training has been compiled. Cadaveric animal models provide a readily available introduction to many procedures and ought to be used instead of live models when feasible. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Design and experimental analysis of a new malleovestibulopexy prosthesis using a finite element model of the human middle ear.

    PubMed

    Vallejo Valdezate, Luis A; Hidalgo Otamendi, Antonio; Hernández, Alberto; Lobo, Fernando; Gil-Carcedo Sañudo, Elisa; Gil-Carcedo García, Luis M

    2015-01-01

    Many designs of prostheses are available for middle ear surgery. In this study we propose a design for a new prosthesis, which optimises mechanical performance in the human middle ear and improves some deficiencies in the prostheses currently available. Our objective was to design and assess the theoretical acoustic-mechanical behaviour of this new total ossicular replacement prosthesis. The design of this new prosthesis was based on an animal model (an iguana). For the modelling and mechanical analysis of the new prosthesis, we used a dynamic 3D computer model of the human middle ear, based on the finite elements method (FEM). The new malleovestibulopexy prosthesis design demonstrates an acoustical-mechanical performance similar to that of the healthy human middle ear. This new design also has additional advantages, such as ease of implantation and stability in the middle ear. This study shows that computer simulation can be used to design and optimise the vibroacoustic characteristics of middle ear implants and demonstrates the effectiveness of a new malleovestibulopexy prosthesis in reconstructing the ossicular chain. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.

  3. [Suture simulator - Cleft palate surgery].

    PubMed

    Devinck, F; Riot, S; Qassemyar, A; Belkhou, A; Wolber, A; Martinot Duquennoy, V; Guerreschi, P

    2017-04-01

    Cleft palate requires surgery in the first years of life, furthermore repairing anatomically the soft and hard palate is complex on a surgical level because of the fine tissues and the local intraoral configuration. It is valuable to train first on simulators before going to the operating room. However, there is no material dedicated to learning how to perform intraoral sutures in cleft palate surgery. We made one, in an artisanal manner, in order to practice before the real surgical gesture. The simulator was designed based on precise anatomical data. A steel pipe, fixed on a rigid base represented the oral cavity. An adapted split spoon represented the palate. All pieces could be removed in order to apply a hydrocellular dressing before training for sutures. Our simulator was tested by 3 senior surgeons in our department in close to real-life conditions in order to evaluate its anatomical accuracy. It is valuable to have a simulator to train on cleft palate sutures within teaching university hospitals that manage this pathology. Our simulator has a very low cost, it is easy to make and is anatomically accurate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  4. Antiadhesive effect of bioresorbable polylactide film in abraded middle ear mucosa.

    PubMed

    Jang, Chul Ho; Jo, Si Young; Cho, Yong Beom; Choi, Cheol Hee; Jung, Won Kyo

    2014-12-01

    Polylactide film (PLF) is used to prevent postoperative peridural adhesion in spinal surgery. Up until now, the antiadhesive effect of bioresorbable PLF in ear middle surgery has not been reported. The purpose of this study is to evaluate the antiadhesive effect of PLF in guinea pigs serving as a model for middle ear mucosal trauma. The animals were divided into two groups: the PLF group and the silastic sheeting group. There were seven guinea pigs (fourteen ears) in both groups. Under aseptic conditions, the middle ear mucosa was abraded using a pick inserted transbullaly. A PLF or silicone sheet was then placed into the guinea pigs' middle ear cavities. The auditory brainstem responses (ABRs) were assessed preoperatively and at three weeks postoperatively while the animals were under general anesthesia. A histopathological study was performed 3 weeks after the operation. The difference between the ABR results before the operation and three weeks postoperatively were not statistically significant. The adhesion formation did not appeared in either group. Prominent fibrous capsule formation and inflammation were observed in the silastic sheeting group, but not in the PLF group. Mild fibrous thickening of regenerated mucosa was observed in the PLF group. From our results, bioresorbable PLF is nonototoxic and biocompatible with the guinea pig's middle ear cavity by short-term evaluation. Further long-term evaluation study is necessary before clinical application. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. Anthropometric growth study of the ear in a Chinese population.

    PubMed

    Zhao, Shichun; Li, Dianguo; Liu, Zhenzhong; Wang, Yibiao; Liu, Lei; Jiang, Duyin; Pan, Bo

    2018-04-01

    A large number of anthropometric studies of the auricle have been reported in different nations, but little data were available in the Chinese population. The aim of this study was to analyze growth changes in the ear by measuring the width and length of ears in a Chinese population. A total of 480 participants were enrolled and classified into 1-, 3-, 5-, 7-, 9-, 12-, 14-, and 18-year groups (half were boys and half were girls in each group). Ear length, ear width, body weight, and body length were measured and recorded; ear index was calculated according to ear length and ear width. The growth of auricle and differences between genders were analyzed. Growth of ear in relation to body height and weight and the degree of emphasis on the length and width of the auricle were also analyzed. Ear length and width increased with age. Ear length achieved its mature size in both 14-year-old males and females. Ear width reached its mature size in males at 7 years and in females at 5 years. Different trends of ear index were shown between males and females. People in this population paid more attention to the length than the width of the auricle. The data indicated that ear development followed increase in age. There were gender and ethnic difference in the development of ear. These results may have potential implications for the diagnosis of congenital malformations, syndromes, and planning of ear reconstruction surgery. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. A Virtual Reality-Based Simulation of Abdominal Surgery

    DTIC Science & Technology

    1994-06-30

    415) 591-7881 In! IhNiI 1 SHORT TITLE: A Virtual Reality -Based Simulation of Abdominal Surgery REPORTING PERIOD: October 31, 1993-June 30, 1994 The...Report - A Virtual Reality -Based Simulation Of Abdominal Surgery Page 2 June 21, 1994 TECHNICAL REPORT SUMMARY Virtual Reality is a marriage between...applications of this technology. Virtual reality systems can be used to teach surgical anatomy, diagnose surgical problems, plan operations. simulate and

  7. [Evaluation of a training system for middle ear surgery with optoelectric detection].

    PubMed

    Strauss, G; Bahrami, N; Pössneck, A; Strauss, M; Dietz, A; Korb, W; Lüth, T; Haase, R; Moeckel, H; Grunert, R

    2009-10-01

    This work presents a new training concept for surgery of the temporal bone. It is based on a model of gypsum plastic with optoelectric detection of risk structures. A prototypical evaluation is given. The training models are based on high-resolution computed tomographic data of a human skull. The resulting data set was printed by a three-dimensional (3D) printer. A 3D phantom is created from gypsum powder and a bonding agent. Risks structures are the facial nerve, semicircular canal, cochlea, ossicular chain, sigmoid sinus, dura, and internal carotid artery. An electrically conductive metal (Wood's metal) and a fiber-optic cable were used as detection materials for the risk structures. For evaluating the training system, a study was done with eight inexperienced and eight experienced ear surgeons. They were asked to perform temporal bone surgery using two identical training models (group A). In group B, the same surgeons underwent surgical training with human cadavers. In the case of injuries, the number, point in time, degree (facial nerve), and injured structure were documented during the training on the model. In addition, the total time needed was noted. The training systems could be used in all cases. Evaluation of the anatomic accuracy of the models showed results that were between 49.5% and 90% agreement with the anatomic origin. Error detection was evaluated with values between 79% and 100% agreement with the perception of an experienced surgeon. The operating setting was estimated to be better than the previous"gold standard." The possibility of completely replacing the previous training method, which uses cadavers, with the examined training model was affirmed. This study shows that the examined system fulfills the conditions for a new training concept for temporal bone surgery. The system connects the preliminary work with printed and sintered models with the possibilities of microsystem engineering. In addition, the model's digital database permits a

  8. Bilateral external ear canal osteomas - discussion on a clinical case.

    PubMed

    Gheorghe, D C; Stanciu, A E; Ulici, A; Zamfir-Chiru-Anton, A

    2016-01-01

    Osteomas of the external ear are uncommon benign tumors that need to be differentiated from the external ear canal exostoses, bony proliferations that are linked mainly to cold-water exposure. Clinical manifestations vary from no symptoms to recurrent local infections and external ear cholesteatoma. Objective: presenting a rare case that we did not find described in the published literature. A patient with multiple long-term asymptomatic osteomas of both external ear canals presented to our department. Material: Data recorded from the patient's medical record was reviewed and analyzed. Surgery was performed and histology confirmed the presumptive diagnosis. Results: There was a discrepancy between the local severity of the disease, with a complete obstruction of his ear canals, and the long-term disease-free status of the patient. Conclusion: We hypothesized about the etiology of these multiple bilateral osteomas of the EAC, in light of the clinical and surgical findings.

  9. The Surgical Challenge of Carotid Artery and Fallopian Canal Dehiscence in Chronic Ear Disease: A Pitfall for Endoscopic Approach

    PubMed Central

    Pauna, Henrique F.; Monsanto, Rafael C.; Schachern, Patricia A.; Costa, Sady S.; Kwon, Geeyoun; Paparella, Michael M.; Cureoglu, Sebahattin

    2016-01-01

    Objective Endoscopic procedures are becoming common in middle ear surgery. Inflammation due to chronic ear disease can cause bony erosion of the carotid artery and Fallopian canals, making them more vulnerable during surgery. The objective of this study was to determine whether or not chronic ear disease increases dehiscence of the carotid artery and Fallopian canals. Design Comparative human temporal bone study. Setting Otopathology laboratory. Participants We selected 78 temporal bones from 55 deceased donors with chronic otitis media or cholesteatoma, and then compared those 2 groups with a control group of 27 temporal bones from 19 deceased donors with no middle ear disease. Main outcome measures We analyzed the middle ear, carotid artery canal, and Fallopian canal, looking for signs of dehiscence of its bony coverage, using light microscopy. Results We found an increased incidence in dehiscence of the carotid artery and Fallopian canals in temporal bones with chronic middle ear disease. The size of the carotid artery canal dehiscence was larger in the middle ear diseased groups, and its bony coverage, when present, was also thinner compared to the control group. Dehiscence of the carotid artery canal was more frequently located closer to the promontory. The incidence of Fallopian canal dehiscence was significantly higher in temporal bones from donors older than 18 years with chronic middle ear disease. Conclusion The increased incidence of the carotid artery and Fallopian canal dehiscence in temporal bones with chronic middle ear disease elevates the risk of adverse events during middle ear surgery. Level of Evidence N/A. PMID:27455393

  10. Pressure and Temperature Changes in In Vitro Applications with the Laser and Their Implications for Middle Ear Surgery

    PubMed Central

    Schwab, Burkard; Kontorinis, Georgios

    2010-01-01

    Background. The purpose of this study was to evaluate the thermal and pressure effects using a Titan Sapphire chirped-pulse amplifier system configured to deliver ultrashort pulses of 180 femtoseconds (fs) in an inner ear model. Materials and Methods. Temperature increases and heat exchange processes in the fluid (physiological saline) were examined in a calorically and physiologically approximated cochlea model for applying laser parameters effective in the creation of footplate perforations. Results. In the effective energy density range, the highest temperature increases achieved with the Carbon dioxide (CO2) laser were about 11 degrees C. The lowest temperature maxima were 6 degrees C with the Er:YAG laser (Yttrium-Aluminum-Oxide doted with Erbium3+-ions) and <5 degrees C with the femtosecond laser. Comparison of the laser-induced pressure with the limit graph published by Pfander indicated that the use of the fs laser is unobjectionable for fluences <1 J/cm2. Conclusions. Our investigations demonstrated that the application of the fs laser in middle ear surgery presents a new and promising addition to the range of ultrashort wavelength lasers used for this purpose. PMID:20953354

  11. Otosclerosis surgery: approaches, profits and complications.

    PubMed

    Japaridze, Sh; Lomidze, L; Jashi, M; Kekelidze, I; Gegenava, Kh

    2009-05-01

    A systematic analysis of stapedoplasty output in otosclerosis cases was carried out. The operations were done during the period of 2005-2008 years at the Department of Otorhinolaryngology of the Tbilisi State Medical University. From the overall number of 107 patients, 78 were females and 29 males, 72.9% and 27.1%, respectively. The ages ranged from 16 to 57 years. The mean age was 35 years. The conductive and mixed forms of hearing losses were diagnosed in 70 and 37 cases, 65.4% and 34.6%, respectively. Right ear was operated in 46 patients, left ear in 57, and both ears in four, 43.3%, 53.0%, and 3.7%, respectively. 111 ears have been cured thus in sum. Intumescences of external ear tube were observed during the operation in 22 patients, 20.6%. In 7, 6.5%, the facial nerve was located downward. Particularly abnormal placement of the facial nerve was the case in two patients, 1.9%. The endaural approach has been proved to own advantages over the transmeatal one. The data generally confirmed that stapedotomy, as compared to stapedectomy, is a better choice for the surgery output. In beneficial cases the air/bone gaps after the operation closed totally or nearly totally. Such a proper outcome was reached in 93 out of 111 ears operated, 83.8%. In most of remainder ears the gaps after the operation narrowed significantly but far not completely. The definite surgery failure happened in one case only, 0.9%. To balance the preserved middle-ear problems in non-perfect surgery cases, the hearing aids of bone-conduction types have been recommended. In mixed otosclerosis cases, conversely, the aids of air-conduction types were advised to overcome the coexisted inner-ear pathologies.

  12. Effects of Cartilage Scoring in Correction of Prominent Ear with Incisionless Otoplasty Technique in Pediatric Patients.

    PubMed

    Haytoğlu, Süheyl; Haytoğlu, Tahir Gökhan; Kuran, Gökhan; Yıldırım, İlhami; Arıkan, Osman Kürşat

    2017-04-01

    The aim of this study was to investigate the efficacy, complication rates, patient satisfaction, and recurrence risks of the incisionless otoplasty technique performed with or without cartilage scoring for correcting the prominent ear in pediatric patients. A total of 49 patients with prominent ears were operated with incisionless otoplasty. In Group 1, 44 ears of 24 patients were operated with incisionless otoplasty without cartilage scoring. In Group 2, 46 ears of 25 patients were operated with incisionless otoplasty with cartilage scoring. For comparison, auriculocephalic distances were measured at three different levels: preoperatively, at the end of surgery, and at 1th and 6th month post-operatively. Patient satisfaction was evaluated using a visual analog scale (VAS). The global esthetic improvement scale (GAIS) was applied by an independent, non-participating plastic surgeon at 6 months after surgery. Prior to surgery and at the end of surgery, no statistically significant difference was observed between the groups in terms of auriculocephalic distances at the three levels. At the and 6th month after surgery, auriculocephalic distances were significantly higher in Group 1. There were no significant differences in VAS results and GAIS values between the groups. The recurrence rate was 9.1% in Group 1 and 4.3% in Group 2. The suture extrusion rate was 18.2% in Group 1 and 13% in Group 2. Although there was a significant difference of 1-2 mm in auriculocephalic distances, our study showed that cartilage scoring is not mandatory to correct the prominent ear in pediatric patients with soft cartilages and to achieve patient and surgeon satisfaction.

  13. Benefits of active middle ear implants in mixed hearing loss: Stapes versus round window.

    PubMed

    Lee, Jeon Mi; Jung, Jinsei; Moon, In Seok; Kim, Sung Huhn; Choi, Jae Young

    2017-06-01

    We compared the audiologic benefits of active middle ear implants with those of passive middle ear implants with hearing aids in mixed hearing loss, and also compared the outcomes of stapes vibroplasty with those of round window vibroplasty. Retrospective chart review. Thirty-four patients with mixed hearing loss due to chronic otitis media were treated with a middle ear implant. Of these, 15 were treated with a passive middle ear implant (conventional ossiculoplasty with a partial ossicular replacement prosthesis), nine with an active middle ear implant coupling to the stapes, and 10 with an active middle ear implant coupling to the round window. Patients underwent pure-tone/free-field audiograms and speech discrimination tests before surgery and 6 months after surgery, and the results of these tests were compared. The active middle ear implant resulted in better outcomes than the passive middle ear implant with hearing aids at mid to high frequencies (P < .05). Patients who received either a stapes vibroplasty or a round window vibroplasty showed comparable hearing gain except at 8,000 Hz (48.9 dB vs. 31.0 dB, P < .05). Patients who received a stapes vibroplasty showed an improvement even in bone conduction at 1,000 Hz and 2,000 Hz (both P < .05). Active middle ear implantation could be a better option than treatment with passive middle ear implants with hearing aids for achieving rehabilitation in patients with mixed hearing loss. Vibroplasty via either oval window or round window stimulation shares similar good results. 4 Laryngoscope, 127:1435-1441, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  14. Finite-Element Modelling of the Acoustic Input Admittance of the Newborn Ear Canal and Middle Ear.

    PubMed

    Motallebzadeh, Hamid; Maftoon, Nima; Pitaro, Jacob; Funnell, W Robert J; Daniel, Sam J

    2017-02-01

    Admittance measurement is a promising tool for evaluating the status of the middle ear in newborns. However, the newborn ear is anatomically very different from the adult one, and the acoustic input admittance is different than in adults. To aid in understanding the differences, a finite-element model of the newborn ear canal and middle ear was developed and its behaviour was studied for frequencies up to 2000 Hz. Material properties were taken from previous measurements and estimates. The simulation results were within the range of clinical admittance measurements made in newborns. Sensitivity analyses of the material properties show that in the canal model, the maximum admittance and the frequency at which that maximum admittance occurs are affected mainly by the stiffness parameter; in the middle-ear model, the damping is as important as the stiffness in influencing the maximum admittance magnitude but its effect on the corresponding frequency is negligible. Scaling up the geometries increases the admittance magnitude and shifts the resonances to lower frequencies. The results suggest that admittance measurements can provide more information about the condition of the middle ear when made at multiple frequencies around its resonance.

  15. Middle Ear Pressures in Wind Instrument Musicians.

    PubMed

    Osborne, Max Sallis; Morris, Simon; Clark, Matthew P; Begg, Philip

    2018-05-22

    This study aimed to assess if playing wind instruments leads to a measurable increase in middle ear pressure during note generation and to provide evidence to clinicians to advise musicians undergoing middle ear surgery. An observational cohort study of 40 volunteers in 7 different wind instrument categories underwent tympanometry at rest and during note production. Community. Recreational musicians aged over 18 years recruited from the student body attending Birmingham University, UK. None. Tympanometry is used as a noninvasive measure of middle ear pressure. The pressure at which peak compliance occurred was taken as an indirect measure of middle ear pressure. The data produced at rest and during note production was statistically analysed with paired t testing and significance set at a p value less than 0.01. Overall a statistically significant increase in middle ear pressure change of 0.63 mm Hg (p = 0.0001) during note production was identified. Musicians playing the oboe and trumpet demonstrate the largest increase in middle ear pressure of 1.46 mm Hg (p = 0.0053) and 0.78 mm Hg (p = 0.0005) respectively. The data provided by this study gives evidence for the first time that playing wind instruments does increase middle ear pressure. Although the clinical significance of this is yet to be determined the authors would advise that musicians who undergo otological procedures should refrain from playing their instruments until full recovery has been achieved as advised by their clinician following direct microscopic review.

  16. Classification and Current Management of Inner Ear Malformations.

    PubMed

    Sennaroğlu, Levent; Bajin, Münir Demir

    2017-09-29

    Morphologically congenital sensorineural hearing loss can be investigated under two categories. The majority of congenital hearing loss causes (80%) are membranous malformations. Here, the pathology involves inner ear hair cells. There is no gross bony abnormality and, therefore, in these cases high-resolution computerized tomography and magnetic resonance imaging of the temporal bone reveal normal findings. The remaining 20% have various malformations involving the bony labyrinth and, therefore, can be radiologically demonstrated by computerized tomography and magnetic resonance imaging. The latter group involves surgical challenges as well as problems in decision-making. Some cases may be managed by a hearing aid, others need cochlear implantation, and some cases are candidates for an auditory brainstem implantation (ABI). During cochlear implantation, there may be facial nerve abnormalities, cerebrospinal fluid leakage, electrode misplacement or difficulty in finding the cochlea itself. During surgery for inner ear malformations, the surgeon must be ready to modify the surgical approach or choose special electrodes for surgery. In the present review article, inner ear malformations are classified according to the differences observed in the cochlea. Hearing and language outcomes after various implantation methods are closely related to the status of the cochlear nerve, and a practical classification of the cochlear nerve deficiency is also provided.

  17. Patients' satisfaction after ear reconstruction with autologous rib cartilage.

    PubMed

    Kristiansen, Martina; Öberg, Martin; Wikström, Sven Olof

    2013-04-01

    Patients' satisfaction is an important outcome measure in reconstructive surgery and quality assurance is today central in the clinical practice. The aim of this study was to evaluate the patients' satisfaction with the process and final result after reconstruction for congenital microtia. A questionnaire was designed and sent to 78 patients who had undergone unilateral ear reconstruction with autologous rib cartilage during the period 2000-2010. For a multidimensional view the patients answered 42 questions about aesthetic, functional, psychosocial, and clinic-related outcomes. The response rate was 76% (59/78 patients). The patients were generally satisfied with the aesthetic result of the ear and had function gain in being able to wear glasses; however, some patients did report new different functional problems after the operation. Still, almost all patients felt that the ear was a part of them and would have chosen the same operative procedure if they could do it again. The patients were overall highly satisfied with the care process. This surgery-specific questionnaire is an important tool for quality assurance in this clinical practice. These findings can help to improve the preoperative information to meet the patients' notions, expectations, and fears.

  18. Virtual reality-based simulators for spine surgery: a systematic review.

    PubMed

    Pfandler, Michael; Lazarovici, Marc; Stefan, Philipp; Wucherer, Patrick; Weigl, Matthias

    2017-09-01

    Virtual reality (VR)-based simulators offer numerous benefits and are very useful in assessing and training surgical skills. Virtual reality-based simulators are standard in some surgical subspecialties, but their actual use in spinal surgery remains unclear. Currently, only technical reviews of VR-based simulators are available for spinal surgery. Thus, we performed a systematic review that examined the existing research on VR-based simulators in spinal procedures. We also assessed the quality of current studies evaluating VR-based training in spinal surgery. Moreover, we wanted to provide a guide for future studies evaluating VR-based simulators in this field. This is a systematic review of the current scientific literature regarding VR-based simulation in spinal surgery. Five data sources were systematically searched to identify relevant peer-reviewed articles regarding virtual, mixed, or augmented reality-based simulators in spinal surgery. A qualitative data synthesis was performed with particular attention to evaluation approaches and outcomes. Additionally, all included studies were appraised for their quality using the Medical Education Research Study Quality Instrument (MERSQI) tool. The initial review identified 476 abstracts and 63 full texts were then assessed by two reviewers. Finally, 19 studies that examined simulators for the following procedures were selected: pedicle screw placement, vertebroplasty, posterior cervical laminectomy and foraminotomy, lumbar puncture, facet joint injection, and spinal needle insertion and placement. These studies had a low-to-medium methodological quality with a MERSQI mean score of 11.47 out of 18 (standard deviation=1.81). This review described the current state and applications of VR-based simulator training and assessment approaches in spinal procedures. Limitations, strengths, and future advancements of VR-based simulators for training and assessment in spinal surgery were explored. Higher-quality studies with

  19. Ear Infection (Middle Ear)

    MedlinePlus

    ... secretions from the middle ear Swelling, inflammation and mucus in the eustachian tubes from an upper respiratory ... your baby for at least six months. Breast milk contains antibodies that may offer protection from ear ...

  20. Effective scoring of scapha prevents helix irregularity in prominent ear correction - a biomechanical study.

    PubMed

    Nagasao, Tomohisa; Miyamoto, Junpei; Shimizu, Yusuke; Kasai, Shogo; Kishi, Kazuo; Kaneko, Tsuyoshi

    2014-09-01

    As the antihelix is created in the operation for prominent ear, the helix often presents irregularities. This biomechanical study aims to elucidate effective techniques to prevent these irregularities. Finite element models were produced simulating 10 prominent ears. The scaphas of the 10 models were thinned to simulate scoring or abrasion of the cartilage. The thinning was conducted in four fashions. In the first group, no thinning was conducted (Non-Scoring Models); in the second group, the upper half of the scapha was thinned (Upper-Scoring Models); in the third group, the lower half of the scapha was thinned (Lower-Scoring Models); in the fourth group, the whole scapha was thinned (Whole-Scoring Models). Mattress sutures were applied to create the antihelix to simulate Mustarde's in-suture technique. Thereafter, transformation of the helix's contour was evaluated. Irregularity developed on the upper region of the helix with Non-Scoring and Lower-Scoring Models; the degree of the upper-region's irregularity was reduced with Upper-Scoring Models and Whole-Scoring Models. Although the edge of the helix moved in the posterior-medial direction with other type models, it moved in the anterior direction with Whole-Scoring Models. Irregularity of the upper region of the helix can be prevented by performing scoring or abrasion of the upper part of the scapha. The prominence of the helix and width of the auricle are adjustable by varying the areas of the scapha receiving scoring or abrasion. These findings are useful in improving operative outcomes in the treatment of prominent ears. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Mechanical simulators for training for laparoscopic surgery in urology.

    PubMed

    Rassweiler, Jens; Klein, Jan; Teber, Dogu; Schulze, Michael; Frede, Thomas

    2007-03-01

    The introduction of laparoscopic surgery into urology has led to new training concepts differing significantly from previous concepts of training for open surgery. This paper focuses on the type and importance of mechanical simulators in laparoscopic training. On the basis of our own studies and experience with the development of various concepts of laparoscopic training, including different modules (i.e., Pelvi-trainer, animal models, clinical mentoring) since 1991, we reviewed the current literature concerning all types of simulators. We focused on training for laparoscopic ablative and reconstructive surgery using mechanical simulators. The principle of a mechanical simulator (i.e., a box with the possibility of trocar insertion) has not changed during the last decade. However, the types of Pelvi-trainers and the models used inside have been improved significantly. According to the task of the simulator, various sophisticated models have been developed, including standardized phantoms, animal organs, and even perfused segments of porcine organs. For laparoscopic suturing, various step-by-step training concepts have been presented. These can be used for determination of the ability of a physician with an interest in laparoscopic surgery, but also to classify the training status of a laparosopic surgeon. Training in laparoscopic surgery has become an important topic, not only in learning a procedure, but also in maintaining skills and preparing for the management of complications. For these purposes, mechanical simulators will definitely play an important role in the future.

  2. 3D printing to simulate laparoscopic choledochal surgery.

    PubMed

    Burdall, Oliver C; Makin, Erica; Davenport, Mark; Ade-Ajayi, Niyi

    2016-05-01

    Laparoscopic simulation has transformed skills acquisition for many procedures. However, realistic nonbiological simulators for complex reconstructive surgery are rare. Life-like tactile feedback is particularly difficult to reproduce. Technological innovations may contribute novel solutions to these shortages. We describe a hybrid model, harnessing 3D technology to simulate laparoscopic choledochal surgery for the first time. Digital hepatic anatomy images and standard laparoscopic trainer dimensions were employed to create an entry level laparoscopic choledochal surgery model. The information was fed into a 3D systems project 660pro with visijet pxl core powder to create a free standing liver mold. This included a cuboid portal in which to slot disposable hybrid components representing hepatic and pancreatic ducts and choledochal cyst. The mold was used to create soft silicone replicas with T28 resin and T5 fast catalyst. The model was assessed at a national pediatric surgery training day. The 10 delegates that trialed the simulation felt that the tactile likeness was good (5.6/10±1.71, 10=like the real thing), was not too complex (6.2/10±1.35; where 1=too simple, 10=too complicated), and generally very useful (7.36/10±1.57, 10=invaluable). 100% stated that they felt they could reproduce this in their own centers, and 100% would recommend this simulation to colleagues. Though this first phase choledochal cyst excision simulation requires further development, 3D printing provides a useful means of creating specific and detailed simulations for rare and complex operations with huge potential for development. Copyright © 2016. Published by Elsevier Inc.

  3. [Modified two-stage surgery for total auriculoplasty with autogenous rib cartilage].

    PubMed

    Zhang, Zheng-wen; Kang, Shen-song; Xie, Feng; Ma, Teng-xiao; Li, Lei; Zhai, Hong-feng; Chou, Hai-yan; Li, Hao; Zhong, Ai-mei; Zhang, Dong-yi

    2011-09-01

    To introduce a modified surgery for total auriculoplasty and the experience in one hundred and forty-six cases (155 ears). The procedure was a two-stage operation. The first stage involved fabrication and grafting of a costal cartilage framework. A U-shaped skin incision was made on the posterior edge of the lobule and the remnant ear cartilage was removed completely. The area for the insertion of the cartilage framework was undermined. Skin flaps were sutured after insertion of the cartilage framework. The second-stage surgery was usually performed six months after the first-stage operation. The reconstructed auricle was elevated, and a costal cartilage block was fixed to the posterior part of the auricle. A temporoparietal fascia flap was then used to cover the costal cartilage block. Finally, the posterior aspect of the projected auricle was covered with a spit-thickness skin graft. The incisions healed in one hundred and forty-one patients (150 ears) after the first stage operation. Partial necrosis of the postauricular flap was observed in five cases (5 ears) after the first stage operation, but no exposure or absorption of the cartilage took place. The skin grafts survived in one hundred and thirty-nine cases (147 ears) after the second-stage surgery. Partial necrosis of the skin graft was observed in seven cases (8 ears), but healed after one-week of dressing changes. Ninety-four cases (97 ears) were followed up, but fifty-two cases (58 ears) were lost to follow up. The follow-up at six months to two years showed satisfactory contour and projection of the constructed ears. This two-stage surgery is simple and ideal for auricloplasty with few complications.

  4. Design, Kinematic Optimization, and Evaluation of a Teleoperated System for Middle Ear Microsurgery

    PubMed Central

    Miroir, Mathieu; Nguyen, Yann; Szewczyk, Jérôme; Sterkers, Olivier; Bozorg Grayeli, Alexis

    2012-01-01

    Middle ear surgery involves the smallest and the most fragile bones of the human body. Since microsurgical gestures and a submillimetric precision are required in these procedures, the outcome can be potentially improved by robotic assistance. Today, there is no commercially available device in this field. Here, we describe a method to design a teleoperated assistance robotic system dedicated to the middle ear surgery. Determination of design specifications, the kinematic structure, and its optimization are detailed. The robot-surgeon interface and the command modes are provided. Finally, the system is evaluated by realistic tasks in experimental dedicated settings and in human temporal bone specimens. PMID:22927789

  5. Carcinoma of the middle ear and external auditory canal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hahn, S.S.; Kim, J.A.; Goodchild, N.

    1983-07-01

    Thirty-one patients with malignant tumors of the middle ear and external auditory canal (EAC) were observed at the University of Virginia Hospital from 1956 through 1980. Of 27 patients with carcinoma, 21 had squamous cell carcinoma, 4 had basal cell carcinoma and 2 had adenoid cystic carcinoma. The 27 patients with carcinoma are reviewed with regard to clinical presentation, treatment modality, results and complications. The majority (67%) of patients had a history of chronic ear drainage, 22% had a previous mastoidectomy or polypectomy and 7% had an associated cholesteatoma. Eighty percent of patients with carcinoma limited to EAC were alivemore » and well at 5 years, compared to 43% of patients with involvement of the middle ear. Fifty-six percent of patients without invasion of the petrous bone were alive at 5 years compared to only 20% of patients with petrous bone involvement. The data strongly suggest that survival depends on the extent of disease. The corrected disease free 5 year survival rates were 14% for patients who had surgery alone and 50% for those who had surgery and radiotherapy. Of the three patients with advanced disease who received radiotherapy alone, none survived five years.« less

  6. A Computer Based Cognitive Simulation of Cataract Surgery

    DTIC Science & Technology

    2011-12-01

    for zonular absence, assess for notable lenticular astigmatism ** How and when do you decide to use a capsular tension ring? (Expert) Zonular...INTRODUCTION The Virtual Mentor Cataract Surgery Trainer is a computer based, cognitive simulation of phacoemulsification cataract surgery. It is...the Cataract Trainer. BODY Phacoemulsification cataract surgery (phaco) is a difficult procedure to learn, with little margin for error. As in other

  7. Modeling Analysis of Biomechanical Changes of Middle Ear and Cochlea in Otitis Media

    NASA Astrophysics Data System (ADS)

    Gan, Rong Z.; Zhang, Xiangming; Guan, Xiying

    2011-11-01

    A comprehensive finite element (FE) model of the human ear including the ear canal, middle ear, and spiral cochlea was developed using histological sections of human temporal bone. The cochlea was modeled with three chambers separated by the basilar membrane and Reissner's membrane and filled with perilymphatic fluid. The viscoelastic material behavior was applied to middle ear soft tissues based on dynamic measurements of tissues in our lab. The model was validated using the experimental data obtained in human temporal bones and then used to simulate various stages of otitis media (OM) including the changes of morphology, mechanical properties, pressure, and fluid level in the middle ear. Function alterations of the middle ear and cochlea in OM were derived from the model and compared with the measurements from temporal bones. This study indicates that OM can be simulated in the FE model to predict the hearing loss induced by biomechanical changes of the middle ear and cochlea.

  8. Virtual reality simulator for vitreoretinal surgery using integrated OCT data.

    PubMed

    Kozak, Igor; Banerjee, Pat; Luo, Jia; Luciano, Cristian

    2014-01-01

    Operative practice using surgical simulators has become a part of training in many surgical specialties, including ophthalmology. We introduce a virtual reality retina surgery simulator capable of integrating optical coherence tomography (OCT) scans from real patients for practicing vitreoretinal surgery using different pathologic scenarios.

  9. Design-Based Comparison of Spine Surgery Simulators: Optimizing Educational Features of Surgical Simulators.

    PubMed

    Ryu, Won Hyung A; Mostafa, Ahmed E; Dharampal, Navjit; Sharlin, Ehud; Kopp, Gail; Jacobs, W Bradley; Hurlbert, R John; Chan, Sonny; Sutherland, Garnette R

    2017-10-01

    Simulation-based education has made its entry into surgical residency training, particularly as an adjunct to hands-on clinical experience. However, one of the ongoing challenges to wide adoption is the capacity of simulators to incorporate educational features required for effective learning. The aim of this study was to identify strengths and limitations of spine simulators to characterize design elements that are essential in enhancing resident education. We performed a mixed qualitative and quantitative cohort study with a focused survey and interviews of stakeholders in spine surgery pertaining to their experiences on 3 spine simulators. Ten participants were recruited spanning all levels of training and expertise until qualitative analysis reached saturation of themes. Participants were asked to perform lumbar pedicle screw insertion on 3 simulators. Afterward, a 10-item survey was administrated and a focused interview was conducted to explore topics pertaining to the design features of the simulators. Overall impressions of the simulators were positive with regards to their educational benefit, but our qualitative analysis revealed differing strengths and limitations. Main design strengths of the computer-based simulators were incorporation of procedural guidance and provision of performance feedback. The synthetic model excelled in achieving more realistic haptic feedback and incorporating use of actual surgical tools. Stakeholders from trainees to experts acknowledge the growing role of simulation-based education in spine surgery. However, different simulation modalities have varying design elements that augment learning in distinct ways. Characterization of these design characteristics will allow for standardization of simulation curricula in spinal surgery, optimizing educational benefit. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Effects of Continuous Positive Airway Pressure on Middle Ear Pressure and Acoustic Stapedial Reflex.

    PubMed

    Li, Jinrang; Li, Keliang

    2016-08-01

    This study investigated the effects of continuous positive airway pressure (CPAP) on middle ear pressure and acoustic stapedial reflex and the correlation between CPAP and middle ear pressure. Prospective cohort study. Tertiary hospitals. Fifty patients with obstructive sleep apnea-hypopnea syndrome were assigned to the study group, and 50 healthy volunteers were assigned to the control group. The subjects underwent standard tympanometry while wearing a CPAP device (ie, simulated CPAP treatment), which was set to 0, 5, 10, and 15 cm H2O, respectively. Tympanometry was performed before and after swallowing at each pressure of CPAP treatment. The mean middle ear pressures were 21.2, 22.6, 22.7, and 23.4 daPa (before swallowing) and 21.6, 42.6, 81.4, and 118.6 daPa (after swallowing) in the study group and 17.6, 18.7, 19.5, and 20.8 daPa (before swallowing) and 17.7, 44.2, 85.6, and 120.5 daPa (after swallowing) in the control group at the CPAPs of 0, 5, 10, and 15 cm H2O, respectively. While the CPAPs were at 0 and 15 cm H2O, the stapedial muscle reflex at 1.0 kHz did not have a significant difference between the 2 groups (χ(2) = 0.521, P = .470). The Pearson correlation coefficient of the CPAP pressure and the middle ear pressure after swallowing was 0.812 (P < .001). CPAP affected middle ear pressure and was directly proportional to the pressure of the CPAP. However, CPAP treatment had no significant effect on stapedial muscle reflex. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  11. Comparison of packing material in an animal model of middle ear trauma.

    PubMed

    Perez, Enrique; Hachem, Ralph Abi; Carlton, Daniel; Bueno, Isabel; Vernon, Stephen; Van De Water, Thomas R; Angeli, Simon I

    2016-01-01

    To compare the performance of absorbable gelatin sponge (AGS) with polyurethane foam (PUF) as middle ear packing material after mucosal trauma. Using a randomized, controlled and blinded study design fifteen guinea pigs underwent middle ear surgery with mucosal trauma performed on both ears. One ear was packed with either PUF or AGS while the contralateral ear remained untreated and used as non-packed paired controls. Auditory brainstem response (ABR) thresholds were measured pre-operatively and repeated at 1, 2, and 6weeks postoperatively. Histological analysis of middle ear mucosa was done in each group to evaluate the inflammatory reaction and wound healing. Another eighteen animals underwent middle ear wounding and packing in one ear while the contralateral ear was left undisturbed as control. Twelve guinea pigs were euthanized at 2weeks postoperatively, and six were euthanized at 3days post-operatively. Mucosal samples were collected for analysis of TGF-β1 levels by enzyme-linked immunosorbent assay. ABR recordings demonstrate that threshold level changes from baseline were minor in PUF packed and control ears. Threshold levels were higher in the AGS packed ears compared with both control and PUF packed ears for low frequency stimuli. Histological analysis showed persistence of packing material at 6weeks postoperatively, inflammation, granulation tissue formation, foreign body reaction and neo-osteogenesis in both AGS and PUF groups. TGF-β1 protein levels did not differ between groups. PUF and AGS packing cause inflammation and neo-osteogenesis in the middle ear following wounding of the mucosa and packing. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. A systematic review of phacoemulsification cataract surgery in virtual reality simulators.

    PubMed

    Lam, Chee Kiang; Sundaraj, Kenneth; Sulaiman, Mohd Nazri

    2013-01-01

    The aim of this study was to review the capability of virtual reality simulators in the application of phacoemulsification cataract surgery training. Our review included the scientific publications on cataract surgery simulators that had been developed by different groups of researchers along with commercialized surgical training products, such as EYESI® and PhacoVision®. The review covers the simulation of the main cataract surgery procedures, i.e., corneal incision, capsulorrhexis, phacosculpting, and intraocular lens implantation in various virtual reality surgery simulators. Haptics realism and visual realism of the procedures are the main elements in imitating the actual surgical environment. The involvement of ophthalmology in research on virtual reality since the early 1990s has made a great impact on the development of surgical simulators. Most of the latest cataract surgery training systems are able to offer high fidelity in visual feedback and haptics feedback, but visual realism, such as the rotational movements of an eyeball with response to the force applied by surgical instruments, is still lacking in some of them. The assessment of the surgical tasks carried out on the simulators showed a significant difference in the performance before and after the training.

  13. Spectacle fitting with ear, nose and face deformities or abnormalities.

    PubMed

    Eng, Helen; Chiu, Roger Sin Fai

    2002-11-01

    Spectacle frame selection and dispensing remain significant components of optometry. Occasionally, we encounter patients who are unable to wear conventional spectacles due to abnormalities or deformities following injury and/or surgery to their nose, ears or head. In these cases, spectacle frame fitting may be more complex and customized frame adjustments may be required to account for the anatomical variations. A patient with a microtia (hypoplastic pinna) was fitted with a tailored spectacle frame. The details are presented together with a summary of different frames and modifications available for ears, nose and face abnormalities.

  14. Virtual reality surgical simulators- a prerequisite for robotic surgery.

    PubMed

    Rajanbabu, Anupama; Drudi, Laura; Lau, Susie; Press, Joshua Z; Gotlieb, Walter H

    2014-06-01

    The field of computer assisted minimally invasive surgery is rapidly expanding worldwide, including in India. With more hospitals in India contemplating the acquisition of a robotic platform, training of robotic surgeons is becoming essential. Virtual reality simulators can be used for surgeons to become acquainted with the robotic console prior to live surgery. Our aim was to evaluate the amount of simulator training required before a surgeon first operates on the da Vinci® Surgical System. Simulations were conducted on the Intuitive Surgical's da Vinci® Robot Skill Simulator using the software obtained from Mimic Technologies. Participants included attending staff surgeons experienced in robotic surgery and novices. A set of seven activities were chosen for each participant. Based on the mean exercise score from the first attempt, staff surgeons outperformed the novices in all exercises. However, the difference in score between the staff and the novices decreased after the participants repeated the exercises and by the sixth attempt most of the novices obtained similar scores to the staff, suggesting that this might be at present the minimum set of repetitions indicated (or required) prior to performing life robotic surgery.

  15. Simulation of arthroscopic surgery using MRI data

    NASA Technical Reports Server (NTRS)

    Heller, Geoffrey; Genetti, Jon

    1994-01-01

    With the availability of Magnetic Resonance Imaging (MRI) technology in the medical field and the development of powerful graphics engines in the computer world the possibility now exists for the simulation of surgery using data obtained from an actual patient. This paper describes a surgical simulation system which will allow a physician or a medical student to practice surgery on a patient without ever entering an operating room. This could substantially lower the cost of medial training by providing an alternative to the use of cadavers. This project involves the use of volume data acquired by MRI which are converted to polygonal form using a corrected marching cubes algorithm. The data are then colored and a simulation of surface response based on springy structures is performed in real time. Control for the system is obtained through the use of an attached analog-to-digital unit. A remote electronic device is described which simulates an imaginary tool having features in common with both arthroscope and laparoscope.

  16. Computational Modeling of Blast Wave Transmission Through Human Ear.

    PubMed

    Leckness, Kegan; Nakmali, Don; Gan, Rong Z

    2018-03-01

    Hearing loss has become the most common disability among veterans. Understanding how blast waves propagate through the human ear is a necessary step in the development of effective hearing protection devices (HPDs). This article presents the first 3D finite element (FE) model of the human ear to simulate blast wave transmission through the ear. The 3D FE model of the human ear consisting of the ear canal, tympanic membrane, ossicular chain, and middle ear cavity was imported into ANSYS Workbench for coupled fluid-structure interaction analysis in the time domain. Blast pressure waveforms recorded external to the ear in human cadaver temporal bone tests were applied at the entrance of the ear canal in the model. The pressure waveforms near the tympanic membrane (TM) in the canal (P1) and behind the TM in the middle ear cavity (P2) were calculated. The model-predicted results were then compared with measured P1 and P2 waveforms recorded in human cadaver ears during blast tests. Results show that the model-derived P1 waveforms were in an agreement with the experimentally recorded waveforms with statistic Kurtosis analysis. The FE model will be used for the evaluation of HPDs in future studies.

  17. A review of simulation platforms in surgery of the temporal bone.

    PubMed

    Bhutta, M F

    2016-10-01

    Surgery of the temporal bone is a high-risk activity in an anatomically complex area. Simulation enables rehearsal of such surgery. The traditional simulation platform is the cadaveric temporal bone, but in recent years other simulation platforms have been created, including plastic and virtual reality platforms. To undertake a review of simulation platforms for temporal bone surgery, specifically assessing their educational value in terms of validity and in enabling transition to surgery. Systematic qualitative review. Search of the Pubmed, CINAHL, BEI and ERIC databases. Assessment of reported outcomes in terms of educational value. A total of 49 articles were included, covering cadaveric, animal, plastic and virtual simulation platforms. Cadaveric simulation is highly rated as an educational tool, but there may be a ceiling effect on educational outcomes after drilling 8-10 temporal bones. Animal models show significant anatomical variation from man. Plastic temporal bone models offer much potential, but at present lack sufficient anatomical or haptic validity. Similarly, virtual reality platforms lack sufficient anatomical or haptic validity, but with technological improvements they are advancing rapidly. At present, cadaveric simulation remains the best platform for training in temporal bone surgery. Technological advances enabling improved materials or modelling mean that in the future plastic or virtual platforms may become comparable to cadaveric platforms, and also offer additional functionality including patient-specific simulation from CT data. © 2015 John Wiley & Sons Ltd.

  18. Sturge-Weber syndrome: ear, nose, and throat issues and neurologic status.

    PubMed

    Irving, Natasha D; Lim, Jae Hyung; Cohen, Bernard; Ferenc, Lisa M; Comi, Anne M

    2010-10-01

    The pathophysiology of Sturge-Weber syndrome is poorly understood, and ear, nose, and throat involvement is possible. These issues can result in frequent illnesses or airway obstruction, affecting patients' neurologic status. Patients with definite brain involvement who reported potential ear, nose, and throat issues on intake questionnaires underwent retrospective reviews of their medical records. We examined the relationships between these issues, secondary surgical interventions, and patients' neurologic status. The most common complaints involved the sinuses and frequent ear infections. Six patients underwent placement of ear tubes, leading to improvements in migraines and stroke-like episodes in one patient, and improved seizure control in four others. Obstructive sleep apnea was confirmed in three patients who underwent sleep studies. Tonsil or adenoid removal occurred in another three patients. Surgery resulted in marked improvements regarding excessive drooling, daytime sleepiness, and breathing problems. These findings suggest that ear, nose, and throat problems occur frequently in patients with Sturge-Weber Syndrome, and when repeated ear infections are associated with uncontrolled seizures, early placement of ear tubes may be beneficial. Furthermore, patients with facial tissue hypertrophy may be at risk for obstructive sleep apnea, and should be appropriately evaluated. Copyright © 2010 Elsevier Inc. All rights reserved.

  19. Silicone impression material foreign body in the middle ear: Two case reports and literature review.

    PubMed

    Suzuki, Nobuyoshi; Okamura, Koji; Yano, Takuya; Moteki, Hideaki; Kitoh, Ryosuke; Takumi, Yutaka; Usami, Shin-ichi

    2015-10-01

    We report two cases of impression material foreign body in the middle ear. The first case had been affected with chronic otitis media. The silicone flowed into the middle ear through a tympanic membrane perforation during the process of making an ear mold. About 4 years and 8 months after, the patient had severe vertigo and deafness. We found bone erosion of the prominence of the lateral semicircular canal and diagnosed labyrinthitis caused by silicone impression material. In the second case silicone flowed into the canal wall down mastoid cavity. Both cases required surgery to remove the foreign body. The clinical courses in such cases are variable and timing of surgery is sometimes difficult. In addition to reporting these two cases, we present here a review of the literature regarding impression material foreign bodies. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Computer Simulation and Digital Resources for Plastic Surgery Psychomotor Education.

    PubMed

    Diaz-Siso, J Rodrigo; Plana, Natalie M; Stranix, John T; Cutting, Court B; McCarthy, Joseph G; Flores, Roberto L

    2016-10-01

    Contemporary plastic surgery residents are increasingly challenged to learn a greater number of complex surgical techniques within a limited period. Surgical simulation and digital education resources have the potential to address some limitations of the traditional training model, and have been shown to accelerate knowledge and skills acquisition. Although animal, cadaver, and bench models are widely used for skills and procedure-specific training, digital simulation has not been fully embraced within plastic surgery. Digital educational resources may play a future role in a multistage strategy for skills and procedures training. The authors present two virtual surgical simulators addressing procedural cognition for cleft repair and craniofacial surgery. Furthermore, the authors describe how partnerships among surgical educators, industry, and philanthropy can be a successful strategy for the development and maintenance of digital simulators and educational resources relevant to plastic surgery training. It is our responsibility as surgical educators not only to create these resources, but to demonstrate their utility for enhanced trainee knowledge and technical skills development. Currently available digital resources should be evaluated in partnership with plastic surgery educational societies to guide trainees and practitioners toward effective digital content.

  1. Comparison of nine methods to estimate ear-canal stimulus levels

    PubMed Central

    Souza, Natalie N.; Dhar, Sumitrajit; Neely, Stephen T.; Siegel, Jonathan H.

    2014-01-01

    The reliability of nine measures of the stimulus level in the human ear canal was compared by measuring the sensitivity of behavioral hearing thresholds to changes in the depth of insertion of an otoacoustic emission probe. Four measures were the ear-canal pressure, the eardrum pressure estimated from it and the pressure measured in an ear simulator with and without compensation for insertion depth. The remaining five quantities were derived from the ear-canal pressure and the Thévenin-equivalent source characteristics of the probe: Forward pressure, initial forward pressure, the pressure transmitted into the middle ear, eardrum sound pressure estimated by summing the magnitudes of the forward and reverse pressure (integrated pressure) and absorbed power. Two sets of behavioral thresholds were measured in 26 subjects from 0.125 to 20 kHz, with the probe inserted at relatively deep and shallow positions in the ear canal. The greatest dependence on insertion depth was for transmitted pressure and absorbed power. The measures with the least dependence on insertion depth throughout the frequency range (best performance) included the depth-compensated simulator, eardrum, forward, and integrated pressures. Among these, forward pressure is advantageous because it quantifies stimulus phase. PMID:25324079

  2. Ear wax

    MedlinePlus

    See your provider if your ears are blocked with wax and you are unable to remove the wax. Also call if you have an ear wax blockage and you develop new symptoms, such as: Drainage from the ear Ear pain Fever Hearing loss that continues after you clean the wax

  3. Retrofacial approach to access the round window for cochlear implantation of malformed ears.

    PubMed

    Rizk, Habib; O'Connell, Brendan; Stevens, Shawn; Meyer, Ted

    2015-03-01

    To report the use of the retrofacial approach for cochlear implantation in three cases of malformed ears with inaccessible round windows through the standard facial recess. Two children with bilateral profound sensorineural hearing loss who were cochlear implant candidates. One patient had bilateral sequential cochlear implantations and the other a unilateral implant. Retrofacial approach to access the posterior mesotympanum and visualize the round window. Ability to complete the surgery with full insertion of the implant and no complications such as facial nerve injury. We implanted three ears in two patients with multiple external and middle ear malformations with an aberrant facial nerve or a posteriorly displaced round window niche. The standard facial recess approach did not allow visualization of the round window. We resorted to a retrofacial approach to access the posterior mesotympanum and proceeded with the surgery through an anterior and inferior cochleostomy or through the round window. In cases with an aberrant facial nerve or inaccessible round window through the facial recess, the retrofacial approach is a good alternative but requires a certain level of expertise and familiarity with temporal bone anatomy. The decision to use an unconventional approach should be considered before surgery, but the ultimate decision may require intraoperative assessment.

  4. Simulations and Measurements of Human Middle Ear Vibrations Using Multi-Body Systems and Laser-Doppler Vibrometry with the Floating Mass Transducer.

    PubMed

    Böhnke, Frank; Bretan, Theodor; Lehner, Stefan; Strenger, Tobias

    2013-10-22

    The transfer characteristic of the human middle ear with an applied middle ear implant (floating mass transducer) is examined computationally with a Multi-body System approach and compared with experimental results. For this purpose, the geometry of the middle ear was reconstructed from μ-computer tomography slice data and prepared for a Multi-body System simulation. The transfer function of the floating mass transducer, which is the ratio of the input voltage and the generated force, is derived based on a physical context. The numerical results obtained with the Multi-body System approach are compared with experimental results by Laser Doppler measurements of the stapes footplate velocities of five different specimens. Although slightly differing anatomical structures were used for the calculation and the measurement, a high correspondence with respect to the course of stapes footplate displacement along the frequency was found. Notably, a notch at frequencies just below 1 kHz occurred. Additionally, phase courses of stapes footplate displacements were determined computationally if possible and compared with experimental results. The examinations were undertaken to quantify stapes footplate displacements in the clinical practice of middle ear implants and, also, to develop fitting strategies on a physical basis for hearing impaired patients aided with middle ear implants.

  5. Low Cost Simulator for Heart Surgery Training

    PubMed Central

    Silva, Roberto Rocha e; Lourenção, Artur; Goncharov, Maxim; Jatene, Fabio B.

    2016-01-01

    Objective Introduce the low-cost and easy to purchase simulator without biological material so that any institution may promote extensive cardiovascular surgery training both in a hospital setting and at home without large budgets. Methods A transparent plastic box is placed in a wooden frame, which is held by the edges using elastic bands, with the bottom turned upwards, where an oval opening is made, "simulating" a thoracotomy. For basic exercises in the aorta, the model presented by our service in the 2015 Brazilian Congress of Cardiovascular Surgery: a silicone ice tray, where one can train to make aortic purse-string suture, aortotomy, aortorrhaphy and proximal and distal anastomoses. Simulators for the training of valve replacement and valvoplasty, atrial septal defect repair and aortic diseases were added. These simulators are based on sewage pipes obtained in construction material stores and the silicone trays and ethyl vinyl acetate tissue were obtained in utility stores, all of them at a very low cost. Results The models were manufactured using inert materials easily found in regular stores and do not present contamination risk. They may be used in any environment and maybe stored without any difficulties. This training enabled young surgeons to familiarize and train different surgical techniques, including procedures for aortic diseases. In a subjective assessment, these surgeons reported that the training period led to improved surgical techniques in the surgical field. Conclusion The model described in this protocol is effective and low-cost when compared to existing simulators, enabling a large array of cardiovascular surgery training. PMID:28076623

  6. Extracellular and intracellular melanin in inflammatory middle ear disease.

    PubMed

    Fritz, Mark A; Roehm, Pamela C; Bannan, Michael A; Lalwani, Anil K

    2014-06-01

    Melanin is a pigmented polymer with a known role in dermal solar protection. In vertebrates, melanogenesis has been reported in leukocyte populations, suggesting a potential role in innate immunity. In this study, we report the novel finding of melanin associated with chronic inflammation and speculate on its potential role in the middle ear and mastoid. Retrospective review of case series. Medical records of six patients who demonstrated melanin in the ear were reviewed. Six patients from 1 to 63 years of age were identified with extracellular melanin and melanin-laden histiocytes within the middle ear and/or mastoid air cells at time of surgery. Concurrent intraoperative findings included cholesteatoma (n = 3), chronic suppurative otitis media (n = 2), and coalescent mastoiditis (n = 1). Histologically, extracellular melanin and melanin-laden histiocytes were identified by Fontana-Masson stain; absence of melanocytes was confirmed by the absence of Melan-A staining. One patient had a positive stain for CD163 (a marker for macrophages). This case series is the first demonstration of melanin within middle ear mucosa without melanocytes in immediate proximity or metastatic melanocytic lesions. Melanin's presence in the setting of inflammation suggests that there may be a heretofore unreported link between the pigmentary and immune systems in the middle ear. 4.

  7. Model-oriented review and multi-body simulation of the ossicular chain of the human middle ear.

    PubMed

    Volandri, G; Di Puccio, F; Forte, P; Manetti, S

    2012-11-01

    The ossicular chain of the human middle ear has a key role in sound conduction since it transfers vibrations from the tympanic membrane to the cochlea, connecting the outer and the inner part of the hearing organ. This study reports firstly a description of the main anatomical features of the middle ear to introduce a detailed survey of its biomechanics, focused on model development, with a collection of geometric, inertial and mechanical/material parameters. The joint issues are particularly discussed from the perspective of developing a model of the middle ear both explanatory and predictive. Such a survey underlines the remarkable dispersion of data, due also to the lack of a standardization of the experimental techniques and conditions. Subsequently, a 3D multi-body model of the ossicular chain and other structures of the middle ear is described. Such an approach is justified as the ossicles were proven to behave as rigid bodies in the human hearing range and was preferred to the more widely used finite element one as it simplifies the model development and improves joint modeling. The displacement of the umbo (a reference point of the tympanic membrane) in the 0.3-6kHz frequency range was defined as input of the model, while the stapes footplate displacement as output. A parameter identification procedure was used to find parameter values for reproducing experimental and numerical reference curves taken from the literature. This simple model might represent a valid alternative to more complex models and might provide a useful tool to simulate pathological/post-surgical/post-traumatic conditions and evaluate ossicular replacement prostheses. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Ear Pieces

    ERIC Educational Resources Information Center

    DiJulio, Betsy

    2011-01-01

    In this article, the author describes an art project wherein students make fanciful connections between art and medicine. This project challenges students to interpret "ear idioms" (e.g. "blow it out your ear," "in one ear and out the other") by relying almost entirely on realistic ear drawings, the placement of them, marks, and values. In that…

  9. An Electroacoustic Hearing Protector Simulator That Accurately Predicts Pressure Levels in the Ear Based on Standard Performance Metrics

    DTIC Science & Technology

    2013-08-01

    earplug and earmuff showing HPD simulator elements for energy flow paths...unprotected or protected ear traditionally start with analysis of energy flow through schematic diagrams based on electroacoustic (EA) analogies between...Schröter, 1983; Schröter and Pösselt, 1986; Shaw and Thiessen, 1958, 1962; Zwislocki, 1957). The analysis method tracks energy flow through fluid and

  10. Evaluation of simulation training in cardiothoracic surgery: the Senior Tour perspective.

    PubMed

    Fann, James I; Feins, Richard H; Hicks, George L; Nesbitt, Jonathan C; Hammon, John W; Crawford, Fred A

    2012-02-01

    The study objective was to introduce senior surgeons, referred to as members of the "Senior Tour," to simulation-based learning and evaluate ongoing simulation efforts in cardiothoracic surgery. Thirteen senior cardiothoracic surgeons participated in a 2½-day Senior Tour Meeting. Of 12 simulators, each participant focused on 6 cardiac (small vessel anastomosis, aortic cannulation, cardiopulmonary bypass, aortic valve replacement, mitral valve repair, and aortic root replacement) or 6 thoracic surgical simulators (hilar dissection, esophageal anastomosis, rigid bronchoscopy, video-assisted thoracoscopic surgery lobectomy, tracheal resection, and sleeve resection). The participants provided critical feedback regarding the realism and utility of the simulators, which served as the basis for a composite assessment of the simulators. All participants acknowledged that simulation may not provide a wholly immersive experience. For small vessel anastomosis, the portable chest model is less realistic compared with the porcine model, but is valuable in teaching anastomosis mechanics. The aortic cannulation model allows multiple cannulations and can serve as a thoracic aortic surgery model. The cardiopulmonary bypass simulator provides crisis management experience. The porcine aortic valve replacement, mitral valve annuloplasty, and aortic root models are realistic and permit standardized training. The hilar dissection model is subject to variability of porcine anatomy and fragility of the vascular structures. The realistic esophageal anastomosis simulator presents various approaches to esophageal anastomosis. The exercise associated with the rigid bronchoscopy model is brief, and adding additional procedures should be considered. The tracheal resection, sleeve resection, and video-assisted thoracoscopic surgery lobectomy models are highly realistic and simulate advanced maneuvers. By providing the necessary tools, such as task trainers and assessment instruments, the Senior

  11. Current status of validation for robotic surgery simulators - a systematic review.

    PubMed

    Abboudi, Hamid; Khan, Mohammed S; Aboumarzouk, Omar; Guru, Khurshid A; Challacombe, Ben; Dasgupta, Prokar; Ahmed, Kamran

    2013-02-01

    To analyse studies validating the effectiveness of robotic surgery simulators. The MEDLINE(®), EMBASE(®) and PsycINFO(®) databases were systematically searched until September 2011. References from retrieved articles were reviewed to broaden the search. The simulator name, training tasks, participant level, training duration and evaluation scoring were extracted from each study. We also extracted data on feasibility, validity, cost-effectiveness, reliability and educational impact. We identified 19 studies investigating simulation options in robotic surgery. There are five different robotic surgery simulation platforms available on the market. In all, 11 studies sought opinion and compared performance between two different groups; 'expert' and 'novice'. Experts ranged in experience from 21-2200 robotic cases. The novice groups consisted of participants with no prior experience on a robotic platform and were often medical students or junior doctors. The Mimic dV-Trainer(®), ProMIS(®), SimSurgery Educational Platform(®) (SEP) and Intuitive systems have shown face, content and construct validity. The Robotic Surgical SimulatorTM system has only been face and content validated. All of the simulators except SEP have shown educational impact. Feasibility and cost-effectiveness of simulation systems was not evaluated in any trial. Virtual reality simulators were shown to be effective training tools for junior trainees. Simulation training holds the greatest potential to be used as an adjunct to traditional training methods to equip the next generation of robotic surgeons with the skills required to operate safely. However, current simulation models have only been validated in small studies. There is no evidence to suggest one type of simulator provides more effective training than any other. More research is needed to validate simulated environments further and investigate the effectiveness of animal and cadaveric training in robotic surgery. © 2012 BJU

  12. Simulated Surgery-an exam for our time? Summary of the current status and development of the MRCGP Simulated Surgery module.

    PubMed

    Hawthorne, Kamila; Denney, Mei Ling; Bewick, Mike; Wakeford, Richard

    2006-01-01

    WHAT IS ALREADY KNOWN IN THIS AREA • The Simulated Surgery module of the MRCGP examination has been shown to be a valid and reliable assessment of clinical consulting skills. WHAT THIS WORK ADDS • This paper describes the further development of the methodology of the Simulated Surgery; showing the type of data analysis currently used to assure its quality and reliability. The measures taken to tighten up case quality are discussed. SUGGESTIONS FOR FUTURE RESEARCH The future development of clinical skills assessments in general practice is discussed. More work is needed on the effectiveness and reliability of lay assessors in complex integrated clinical cases. New methods to test areas that are difficult to reproduces in a simulated environment (such as acute emergencies and cases with the very young or very old) are also needed.

  13. Surgical treatment for the aberrant internal carotid artery in the middle ear with pulsatile tinnitus.

    PubMed

    Honkura, Yohei; Hidaka, Hiroshi; Ohta, Jun; Gorai, Shigeki; Katori, Yukio; Kobayashi, Toshimitsu

    2014-04-01

    Many previous reports have indicated that pulsatile tinnitus caused by an aberrant internal carotid artery (ICA) should not be treated surgically because of the risk of infection or aneurysm formation. We herein describe a case of aberrant ICA treated by middle ear surgery for which we introduced a novel approach. An 84-year-old man was presented with a one-year history of tinnitus in his right ear. Otoscopic examination demonstrated a whitish mass in the antero-inferior quadrant of the tympanic membrane associated with rhythmic pulsation. Images obtained by CT, MRI and MRA revealed protrusion of the ICA into the tympanic cavity, making contact with the tympanic membrane. Surgery to separate the tympanic membrane from the ICA was performed in order to relieve the pulsatile tinnitus. After the operation, the patient's aural activity was preserved and the tinnitus did not recur within a follow-up period of one year. In the present case, delicate middle ear surgery was effective for relief of the tinnitus. When treating patients with aberrant IAC showing features similar to the present case, the surgical approach we have described is worth attempting. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. Ewing Sarcoma of the External Ear Canal

    PubMed Central

    Kecelioglu Binnetoglu, Kiymet; Gerin, Fatma; Sari, Murat

    2016-01-01

    Background. Ewing sarcoma (ES) is a high-grade malignant tumor that has skeletal and extraskeletal forms and consists of small round cells. In the head and neck region, reported localization of extraskeletal ES includes the larynx, thyroid gland, submandibular gland, nasal fossa, pharynx, skin, and parotid gland, but not the external ear canal. Methods. We present the unique case of a 2-year-old boy with extraskeletal ES arising from the external ear canal, mimicking auricular hematoma. Results. Surgery was performed and a VAC/IE (vincristine, adriamycin, cyclophosphamide alternating with ifosfamide, and etoposide) regimen was used for adjuvant chemotherapy for 12 months. Conclusion. The clinician should consider extraskeletal ES when diagnosing tumors localized in the head and neck region because it may be manifested by a nonspecific clinical picture mimicking common otorhinolaryngologic disorders. PMID:27313930

  15. Ear wax

    PubMed Central

    2008-01-01

    Introduction Ear wax only becomes a problem if it causes a hearing impairment or other ear-related symptoms. Ear wax is more likely to accumulate and cause a hearing impairment when normal extrusion is prevented — for example, by the use of hearing aids, or by the use of cotton buds to clean the ears. Ear wax can visually obscure the ear drum, and may need to be removed for diagnostic purposes. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical question: What are the effects of methods to remove ear wax? We searched: Medline, Embase, The Cochrane Library, and other important databases up to June 2007 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found nine systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review, we present information relating to the effectiveness and safety of the following interventions: ear syringing; manual removal (other than ear syringing); and wax softeners (alone or prior to syringing). PMID:19450340

  16. Comparison of palanosetron, granisetron and ondansetron as anti-emetics for prevention of postoperative nausea and vomiting in patients undergoing middle ear surgery.

    PubMed

    Basu, Anjana; Saha, Debdas; Hembrom, Bani P; Roy, Amit; Naaz, Anjum

    2011-05-01

    The objective of the study was to compare the efficacy of palanosetron (0.25 mg), granisetron (3.0 mg) and ondansetron (8.0 mg) used as anti-emetics for the prevention of postoperative nausea/vomiting in patients undergoing middle ear surgery. The study was done among 75 adult patients (age group 30-45 years) of which 50 were males and rest (25) females, all of ASA I and ASA II. The patients were randomly allocated into 3 equal groups: Group I (n = 25) received injection palanosetron (0.25 mg) IV, group II (n = 25) received injection granisetron (3 mg) IV and group III (n = 25) received injection ondansetron (8.0 mg) IV at the end of the surgical procedure. A standard general anaesthesia technique was employed. Emetic episodes and safety assessments were performed during two periods of 0-6 hours in the postanaesthesia care unit and 6-24 hours in the ward after anaesthesia. The incidence of emesis-free patients during the 0-6 hours period was 100% for group I; 72% for group II and 56% for group III. During the 6-24 hours period incidence of emesis-free patients were 96% for group I; 56% for group II and 32% for group III. So to conclude, a single dose of palanosetron (0.25 mg) is a superior anti-emetic to granisetron (3.0 mg) or ondansetron (8.0 mg) in complete prevention of postoperative nausea and vomiting after middle ear surgery during the first 24 hours period.

  17. Otopolyposis With Middle Ear Allergic Mucin in a Patient With Allergic Fungal Rhinosinusitis.

    PubMed

    Kumar, Manvinder S; Panella, Nicholas J; Magliocca, Kelly R; Vivas, Esther X

    2016-10-01

    The purpose of this study is to report a case of otopolyposis and middle ear allergic mucin in a patient with allergic fungal rhinosinusitis (AFRS) and no history of middle ear disease and introduce these as possible otologic manifestations of the AFRS. A case of a 31-year-old female with the aforementioned findings is reported. A review of the pertinent literature was performed. We report a case of a 31-year-old female with a history of AFRS but no history of middle ear disease or hearing loss who presented to our institution complaining of aural fullness. Physical exam was significant for middle ear masses of unknown etiology. Surgical exploration revealed the presence of allergic mucin and middle ear polyposis histologically identical to tissue sampled during prior sinonasal surgeries at the same institution. Aspiration of the middle ear space did not resolve the otologic symptoms. Otopolyposis and middle ear allergic mucin are extremely rare but possible otologic manifestations of AFRS. We encourage otolaryngologists to consider this in the clinical differential diagnosis of patients with a history of AFRS with new onset otologic symptoms. © The Author(s) 2016.

  18. Ear Disorders

    MedlinePlus

    ... most common illness in infants and young children. Tinnitus, a roaring in your ears, can be the ... problems in your inner ear; its symptoms include tinnitus and dizziness. Ear barotrauma is an injury to ...

  19. Roles of an anti-tuberculosis medication and surgery in patients with tuberculous otitis media.

    PubMed

    Kwon, Minsu; Choi, Seung Hyo; Chung, Jong Woo

    2010-06-01

    The standard treatment for tuberculous otitis media (TOM) without complications consists of anti-tuberculosis (anti-TB) medication, with which we experienced good treatment outcomes. However, surgery is required for recovery of anatomy and hearing function. To determine the clinical characteristics of TOM that might optimize diagnosis and to evaluate the differences in clinical courses between patients treated with and without surgery. We analyzed 14 patients (16 ears) who had been diagnosed and treated for TOM. Radiologic findings, laboratory data, and audiometry results were also evaluated. Patients were divided into a chemotherapy group and a surgery group according to treatment modality. Temporal bone CT (TBCT) showed total occupation of the tympanic cavity by soft tissue and little evidence of ossicular erosion. In the chemotherapy group, dry ears were obtained in all but one patient (14 ears) after treatment. Normalized tympanic membrane (TM) was found in 50% in the chemotherapy group and in 75% in the surgery group. The air-bone gap (ABG) changed from 40.3 +/- 2.5 dB to 47.0 +/- 19.2 dB in the chemotherapy group and from 35.2 +/- 7.6 dB to 30.2 +/- 11.4 dB in the surgery group. After treatment, ABG improved by > 10 dB in one ear in the chemotherapy group and in four ears in the surgery group.

  20. Incorporating simulation in vascular surgery education.

    PubMed

    Bismuth, Jean; Donovan, Michael A; O'Malley, Marcia K; El Sayed, Hosam F; Naoum, Joseph J; Peden, Eric K; Davies, Mark G; Lumsden, Alan B

    2010-10-01

    The traditional apprenticeship model introduced by Halsted of "learning by doing" may just not be valid in the modern practice of vascular surgery. The model is often criticized for being somewhat unstructured because a resident's experience is based on what comes through the "door." In an attempt to promote uniformity of training, multiple national organizations are currently delineating standard curricula for each trainee to govern the knowledge and cases required in a vascular residency. However, the outcomes are anything but uniform. This means that we graduate vascular specialists with a surprisingly wide spectrum of abilities. Use of simulation may benefit trainees in attaining a level of technical expertise that will benefit themselves and their patients. Furthermore, there is likely a need to establish a simulation-based certification process for graduating trainees to further ascertain minimum technical abilities. Copyright © 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  1. Interventions for the prevention of postoperative ear discharge after insertion of ventilation tubes (grommets) in children.

    PubMed

    Syed, Mohammed Iqbal; Suller, Sharon; Browning, George G; Akeroyd, Michael A

    2013-04-30

    Grommets are frequently inserted in children's ears for acute otitis media and otitis media with effusion. A common complication is postoperative ear discharge (otorrhoea). A wide range of treatments are used to prevent the discharge, but there is no consensus on whether or not intervention is necessary nor which is the most effective intervention. To assess the effectiveness of prophylactic interventions, both topical and systemic, in reducing the incidence of otorrhoea following the surgical insertion of grommets in children. We searched the Cochrane Ear, Nose and Throat Disorders Group Trials Register; the Cochrane Central Register of Controlled Trials (CENTRAL); PubMed; EMBASE; CINAHL; Web of Science; BIOSIS Previews; Cambridge Scientific Abstracts; ICTRP and additional sources for published and unpublished trials. The date of the search was 3 July 2012. We included randomised controlled trials (RCTs) that compared the efficacy of prophylactic interventions against placebo/control and/or with other prophylactic interventions for postoperative otorrhoea in children. Two review authors independently assessed study eligibility and risk of bias, and extracted data. The outcome data were dichotomous for all the included trials. We calculated individual and pooled risk ratios (RR) using the Mantel-Haenszel fixed-effect method. We also calculated the numbers needed to treat to benefit (NNTB). We found 15 eligible RCTs (2476 children, aged from four months to 17 years). We graded seven RCTs as being at a low risk of bias (n = 926 children) and for an eighth RCT we also graded two of the arms as being at a low risk of bias. We graded the other seven trials as being at a high risk of bias.For a single application at surgery, there was evidence from two low risk of bias trials that at two weeks postoperatively the risk of otorrhoea was reduced by multiple saline washouts (from 30% to 16%; RR 0.52, 95% confidence interval (CI) 0.27 to 1.00; NNTB 7; one RCT; 140 children

  2. Validation of a novel virtual reality simulator for robotic surgery.

    PubMed

    Schreuder, Henk W R; Persson, Jan E U; Wolswijk, Richard G H; Ihse, Ingmar; Schijven, Marlies P; Verheijen, René H M

    2014-01-01

    With the increase in robotic-assisted laparoscopic surgery there is a concomitant rising demand for training methods. The objective was to establish face and construct validity of a novel virtual reality simulator (dV-Trainer, Mimic Technologies, Seattle, WA) for the use in training of robot-assisted surgery. A comparative cohort study was performed. Participants (n = 42) were divided into three groups according to their robotic experience. To determine construct validity, participants performed three different exercises twice. Performance parameters were measured. To determine face validity, participants filled in a questionnaire after completion of the exercises. Experts outperformed novices in most of the measured parameters. The most discriminative parameters were "time to complete" and "economy of motion" (P < 0.001). The training capacity of the simulator was rated 4.6 ± 0.5 SD on a 5-point Likert scale. The realism of the simulator in general, visual graphics, movements of instruments, interaction with objects, and the depth perception were all rated as being realistic. The simulator is considered to be a very useful training tool for residents and medical specialist starting with robotic surgery. Face and construct validity for the dV-Trainer could be established. The virtual reality simulator is a useful tool for training robotic surgery.

  3. Closed anterior scoring for prominent-ear correction revisited.

    PubMed

    Thomas, S S; Fatah, F

    2001-10-01

    The closed-anterior-scoring technique has been used over the past 3 years to correct 56 prominent ears in 32 patients at the West Midlands Regional Plastic Surgery Unit at Wordsley Hospital. A review was carried out to assess the result of this surgical procedure. We briefly discuss the historical development of other surgical techniques for prominent-ear correction, and describe in detail the operative technique for this procedure, which includes closed scoring and suturing of the cartilage. We used this technique to treat 24 patients with bilateral prominent ears and eight patients with unilateral prominent ears. The series comprised 20 females and 12 males, 26 children and six adults. The age range was from 4 to 24 years old. There were two complications (an upper-pole recurrence and protrusion of a buried prolene suture). Patients were followed up for between 6 months and 3 years (mean: 1.5 years). This procedure is quick and technically easy to learn, with no anterior scars or posterior cartilage overlap. Minimal dissection is involved, leading to a low rate of complications. The learning curve is rapid; this paper represents the experience of a specialist trainee (SST) after he was taught the technique by the senior author. Copyright 2001 The British Association of Plastic Surgeons.

  4. Swimmer's Ear

    MedlinePlus

    ... Eardrum Taking Care of Your Ears Can Loud Music Hurt My Ears? Your Ears What's Earwax? How Do Pain Relievers Work? View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...

  5. [Keloid scars of the external ear: a non solved problem].

    PubMed

    Bejarano Serrano, M; Parri Ferrandis, F J; García Smith, N I; Martínez-Herrada, S; Manzanares Quintela, A; Albert Cazalla, A

    2014-01-01

    The external ear is a location with high risk of keloid scar formation. Its incidence is growing since general use of piercings and performance of plastic surgery of the external ear. The external ear keloid can be a devasting process for adolescent population which is worried about their appearance. Our aim is to attract attention about the risk of keloid scars of the external ear, reviewing our experience. After dismissing radiotherapy, corticoid infiltration and surgical removal are the most used options, with a high recurrence risk. We have reviewed traumatic, surgical and piercing wounds of the external ear, with a subsequent keloid formation treated in our outpatient clinic, collecting data about wound etiology, treatment and results. During the last 10 years we have found 11 keloid scars, 2 of them improved with topical corticosteroid. Treatment has been surgical in 9 cases, 4 of them with skin graft: 5 recovered and 4 recurred; 2 of them were reoperated. 2 of them were treated with intralesional corticosteroid solely, one recovered and the other one had improved. Treatment management of keloid scars is complex and there isn't a procedure with superior results than the others. Risk of complication must be explained within adolescent population.

  6. Ear Scaffold Reconstruction Using Ultrasonic Aspirator for Cauliflower Ear.

    PubMed

    Hao, Scarlett; Angster, Kristen; Hubbard, Fleesie; Greywoode, Jewel; Vakharia, Kalpesh T

    2018-04-01

    Untreated auricular hematomas from ear trauma can result in an ear deformation known as cauliflower ear, secondary to fibrosis and new cartilage overgrowth. Cauliflower ear reconstruction has traditionally utilized tools such as a drill or a scalpel in order to improve auricular cosmesis. We present a case report utilizing an ultrasonic aspirator to recontour the fibrosed cartilage of a cauliflower ear. The ultrasonic aspirator has advantages over traditional tools in its ability to provide finely controlled bone removal without damage to surrounding soft tissue. The patient in this case report underwent multistage reconstruction using the ultrasonic aspirator with excellent cosmetic result and patient satisfaction.

  7. Ear Problems

    MedlinePlus

    ... may have OTITIS MEDIA, an infection of the middle ear. Self CareSee your doctor. Many ear infections will ... half-alcohol, half-white vinegar solution in the ear before and after swimming or ... JOINT (TMJ) SYNDROME, a disorder that affects the jaw joint, may ...

  8. Current state of virtual reality simulation in robotic surgery training: a review.

    PubMed

    Bric, Justin D; Lumbard, Derek C; Frelich, Matthew J; Gould, Jon C

    2016-06-01

    Worldwide, the annual number of robotic surgical procedures continues to increase. Robotic surgical skills are unique from those used in either open or laparoscopic surgery. The acquisition of a basic robotic surgical skill set may be best accomplished in the simulation laboratory. We sought to review the current literature pertaining to the use of virtual reality (VR) simulation in the acquisition of robotic surgical skills on the da Vinci Surgical System. A PubMed search was conducted between December 2014 and January 2015 utilizing the following keywords: virtual reality, robotic surgery, da Vinci, da Vinci skills simulator, SimSurgery Educational Platform, Mimic dV-Trainer, and Robotic Surgery Simulator. Articles were included if they were published between 2007 and 2015, utilized VR simulation for the da Vinci Surgical System, and utilized a commercially available VR platform. The initial search criteria returned 227 published articles. After all inclusion and exclusion criteria were applied, a total of 47 peer-reviewed manuscripts were included in the final review. There are many benefits to utilizing VR simulation for robotic skills acquisition. Four commercially available simulators have been demonstrated to be capable of assessing robotic skill. Three of the four simulators demonstrate the ability of a VR training curriculum to improve basic robotic skills, with proficiency-based training being the most effective training style. The skills obtained on a VR training curriculum are comparable with those obtained on dry laboratory simulation. The future of VR simulation includes utilization in assessment for re-credentialing purposes, advanced procedural-based training, and as a warm-up tool prior to surgery.

  9. Adenoid cystic carcinoma of the external ear: a population based study.

    PubMed

    Green, Ross W; Megwalu, Uchechukwu C

    2016-01-01

    To determine the incidence of adenoid cystic carcinoma of the external ear in the United States, and to evaluate the clinical characteristics and survival outcomes associated with the disease. Data were extracted from the Surveillance, Epidemiology, and End Results (SEER) 18 Database of the National Cancer Institute. The study cohort included patients diagnosed with adenoid cystic carcinoma of the external ear from 1973 to 2012. The incidence of adenoid cystic carcinoma of the external ear was 0.004 per 100,000. The SEER database identified 66 patients meeting the inclusion criteria. Nodal metastasis was noted in 13.1% of patients, while 7.9% had distant metastasis. Distant metastasis was associated with worse overall survival (HR 10.18). However, nodal metastasis had no impact on overall survival (HR 0.15, p = 0.09). Surgery alone was associated with improved overall survival (HR 0.26), compared with combination surgery and radiotherapy, while radiotherapy alone was associated with worse overall survival (HR 20.12). Increasing age (HR 1.12) and black race (HR 6.83) were associated with worse overall survival, while female sex (HR 0.26) was associated with improved overall survival. ACC of the external ear is rare. Distant metastasis is a poor prognostic factor. However, nodal metastasis does not appear to impact survival. Advanced age, black race, and male sex are also poor prognostic factors. Surgical resection alone is associated with better survival than combination surgical resection and radiation, or radiotherapy alone. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Validation of a Novel Virtual Reality Simulator for Robotic Surgery

    PubMed Central

    Schreuder, Henk W. R.; Persson, Jan E. U.; Wolswijk, Richard G. H.; Ihse, Ingmar; Schijven, Marlies P.; Verheijen, René H. M.

    2014-01-01

    Objective. With the increase in robotic-assisted laparoscopic surgery there is a concomitant rising demand for training methods. The objective was to establish face and construct validity of a novel virtual reality simulator (dV-Trainer, Mimic Technologies, Seattle, WA) for the use in training of robot-assisted surgery. Methods. A comparative cohort study was performed. Participants (n = 42) were divided into three groups according to their robotic experience. To determine construct validity, participants performed three different exercises twice. Performance parameters were measured. To determine face validity, participants filled in a questionnaire after completion of the exercises. Results. Experts outperformed novices in most of the measured parameters. The most discriminative parameters were “time to complete” and “economy of motion” (P < 0.001). The training capacity of the simulator was rated 4.6 ± 0.5 SD on a 5-point Likert scale. The realism of the simulator in general, visual graphics, movements of instruments, interaction with objects, and the depth perception were all rated as being realistic. The simulator is considered to be a very useful training tool for residents and medical specialist starting with robotic surgery. Conclusions. Face and construct validity for the dV-Trainer could be established. The virtual reality simulator is a useful tool for training robotic surgery. PMID:24600328

  11. Surgical robot setup simulation with consistent kinematics and haptics for abdominal surgery.

    PubMed

    Hayashibe, Mitsuhiro; Suzuki, Naoki; Hattori, Asaki; Suzuki, Shigeyuki; Konishi, Kozo; Kakeji, Yoshihiro; Hashizume, Makoto

    2005-01-01

    Preoperative simulation and planning of surgical robot setup should accompany advanced robotic surgery if their advantages are to be further pursued. Feedback from the planning system will plays an essential role in computer-aided robotic surgery in addition to preoperative detailed geometric information from patient CT/MRI images. Surgical robot setup simulation systems for appropriate trocar site placement have been developed especially for abdominal surgery. The motion of the surgical robot can be simulated and rehearsed with kinematic constraints at the trocar site, and the inverse-kinematics of the robot. Results from simulation using clinical patient data verify the effectiveness of the proposed system.

  12. Supporting skill acquisition in cochlear implant surgery through virtual reality simulation.

    PubMed

    Copson, Bridget; Wijewickrema, Sudanthi; Zhou, Yun; Piromchai, Patorn; Briggs, Robert; Bailey, James; Kennedy, Gregor; O'Leary, Stephen

    2017-03-01

    To evaluate the effectiveness of a virtual reality (VR) temporal bone simulator in training cochlear implant surgery. We compared the performance of 12 otolaryngology registrars conducting simulated cochlear implant surgery before (pre-test) and after (post-tests) receiving training on a VR temporal bone surgery simulator with automated performance feedback. The post-test tasks were two temporal bones, one that was a mirror image of the temporal bone used as a pre-test and the other, a novel temporal bone. Participant performances were assessed by an otologist with a validated cochlear implant competency assessment tool. Structural damage was derived from an automatically generated simulator metric and compared between time points. Wilcoxon signed-rank test showed that there was a significant improvement with a large effect size in the total performance scores between the pre-test (PT) and both the first and second post-tests (PT1, PT2) (PT-PT1: P = 0.007, r = 0.78, PT-PT2: P = 0.005, r = 0.82). The results of the study indicate that VR simulation with automated guidance can effectively be used to train surgeons in training complex temporal bone surgeries such as cochlear implantation.

  13. A modification of incisionless otoplasty for correcting the prominent ear deformity.

    PubMed

    Haytoglu, Suheyl; Haytoglu, Tahir Gokhan; Yildirim, Ilhami; Arikan, Osman Kursat

    2015-11-01

    This article describes a modification of the incisionless otoplasty. We investigated the complication rates, recurrence risks, and patient satisfaction with this modified procedure. In total, 26 patients (49 ears) complaining of prominent ear were operated on. Auriculocephalic distances were measured at three different levels, pre-operatively, at the end of the surgery, and at 4 weeks and 6 months after surgery to evaluate the efficacy of the technique. Patient satisfaction was evaluated using a visual analog scale and the global aesthetic improvement scale was applied by an independent non-participating plastic surgeon at 6 months after the surgery. The mean loss of medialization was ~1 mm at 4 weeks after surgery and 2 mm at 6 months after surgery for all levels. According to visual analog scale, patient or parent satisfaction increased significantly. The global aesthetic improvement scale rated the patients as 93.9% "improved" and 6.1% as "no change." No rating was "worse." There are many advantages of this technique. The operation is not time-consuming, does not require a dressing, and it can be performed in adults with local anesthesia under office conditions, with no need for hospitalization. After the operation, patients can return to their daily activities immediately. It is associated with a low complication rate and high patient satisfaction. This technique is a good option for otoplasty in patients with isolated, inadequate development of anti-helical ridge, and with soft auricular cartilage.

  14. Ear Tubes

    MedlinePlus

    ... of the ear drum or eustachian tube, Down Syndrome, cleft palate, and barotrauma (injury to the middle ear caused by a reduction of air pressure, ... specialist) may be warranted if you or your child has experienced repeated ... fluid in the middle ear, barotrauma, or have an anatomic abnormality that ...

  15. Reconstruction of partially amputated external ear with costal cartilage graft: case report.

    PubMed

    Brunelli, A; Bottini, D J; Cervelli, V; Cervelli, G; Grimaldi, M

    2004-06-01

    Many causes are responsible for secondary anomalies of the outer ear, such as: car accidents, sport- or work-related accidents, assaults, bites from animals or humans, benign or malignant tumours, burns and the effects of surgical interventions of the ear (plastic surgery on the ear or attempts at correction of primary malformations of the ear). The anatomical complexity of the ear makes its reconstruction particularly complicated with post-operative results that are often disappointing. The Authors describe their experience in the reconstruction of a partially amputated outer ear following a dog bite. The therapeutic protocol required various surgical stages. Initially, a cutaneous expander was applied at the level of the mastoid in order to ensure a sufficient quantity of local skin. The second stage was to remove cartilage from the ribs, followed by construction of a cartilaginous model of the ear and its insertion into the subcutaneous mastoid region after removal of the cutaneous expander and any residual ear cartilage. The last stage was to separate the neo-formed outer ear from the mastoid skin with the insertion of a cartilage graft to the posterior region of the reconstructed ear. This graft was covered by the occipital fascia rotated at 180 degrees and by a skin graft removed from the pubis. The postoperative result was satisfactory with recuperation of a good aesthetic appearance of the ear. Aim of the present report is to describe the surgical technique employed in the reconstruction of secondary anomalies of the ear and to highlight errors committed during this procedure. These considerations have allowed us to stress some fundamental elements in the reconstruction of the ear. In particular, the watershed was the awareness that we had to create a cartilaginous model that respected, as far as possible, the anatomy of the outer ear with all its ridges, trenches and cavities. This as well as ensuring a sufficient quantity of local skin in order to cover

  16. A Systematic Review of Virtual Reality Simulators for Robot-assisted Surgery.

    PubMed

    Moglia, Andrea; Ferrari, Vincenzo; Morelli, Luca; Ferrari, Mauro; Mosca, Franco; Cuschieri, Alfred

    2016-06-01

    No single large published randomized controlled trial (RCT) has confirmed the efficacy of virtual simulators in the acquisition of skills to the standard required for safe clinical robotic surgery. This remains the main obstacle for the adoption of these virtual simulators in surgical residency curricula. To evaluate the level of evidence in published studies on the efficacy of training on virtual simulators for robotic surgery. In April 2015 a literature search was conducted on PubMed, Web of Science, Scopus, Cochrane Library, the Clinical Trials Database (US) and the Meta Register of Controlled Trials. All publications were scrutinized for relevance to the review and for assessment of the levels of evidence provided using the classification developed by the Oxford Centre for Evidence-Based Medicine. The publications included in the review consisted of one RCT and 28 cohort studies on validity, and seven RCTs and two cohort studies on skills transfer from virtual simulators to robot-assisted surgery. Simulators were rated good for realism (face validity) and for usefulness as a training tool (content validity). However, the studies included used various simulation training methodologies, limiting the assessment of construct validity. The review confirms the absence of any consensus on which tasks and metrics are the most effective for the da Vinci Skills Simulator and dV-Trainer, the most widely investigated systems. Although there is consensus for the RoSS simulator, this is based on only two studies on construct validity involving four exercises. One study on initial evaluation of an augmented reality module for partial nephrectomy using the dV-Trainer reported high correlation (r=0.8) between in vivo porcine nephrectomy and a virtual renorrhaphy task according to the overall Global Evaluation Assessment of Robotic Surgery (GEARS) score. In one RCT on skills transfer, the experimental group outperformed the control group, with a significant difference in overall

  17. Prevailing Trends in Haptic Feedback Simulation for Minimally Invasive Surgery.

    PubMed

    Pinzon, David; Byrns, Simon; Zheng, Bin

    2016-08-01

    Background The amount of direct hand-tool-tissue interaction and feedback in minimally invasive surgery varies from being attenuated in laparoscopy to being completely absent in robotic minimally invasive surgery. The role of haptic feedback during surgical skill acquisition and its emphasis in training have been a constant source of controversy. This review discusses the major developments in haptic simulation as they relate to surgical performance and the current research questions that remain unanswered. Search Strategy An in-depth review of the literature was performed using PubMed. Results A total of 198 abstracts were returned based on our search criteria. Three major areas of research were identified, including advancements in 1 of the 4 components of haptic systems, evaluating the effectiveness of haptic integration in simulators, and improvements to haptic feedback in robotic surgery. Conclusions Force feedback is the best method for tissue identification in minimally invasive surgery and haptic feedback provides the greatest benefit to surgical novices in the early stages of their training. New technology has improved our ability to capture, playback and enhance to utility of haptic cues in simulated surgery. Future research should focus on deciphering how haptic training in surgical education can increase performance, safety, and improve training efficiency. © The Author(s) 2016.

  18. The prominent antihelix and helix--the myth of the 'overcorrected' ear in otoplasty.

    PubMed

    Shokrollahi, Kayvan; Manning, Steven; Sadri, Amir; Molajo, Adeyinka; Lineaweaver, William

    2015-06-01

    Classic teaching of ear anatomy in the context of otoplasty states that if the antihelical fold is more prominent than the helical fold after surgery then the ear is "overcorrected." We set out to explore the role of the antihelix in normal ear anatomy, its relevance to aesthetic perceptions of the ear, and a snapshot of its incidence in nonoperated ears. To readily identify junior staff in our department, their color photographs, names, and contact details are posted on every ward. Using digital methods, we cropped the left ear out of the source images, making them unidentifiable. Clinical and nonclinical staff in our unit were asked to choose their favorite and their least favorite ears based on their aesthetic appeal. Responses were tabulated and the 2 most popular ears were compared. The preferred ear did not conform to the traditional dogma because it had a prominent antihelix and was statistically significant when compared to other choices. We also noted that a prominent antihelix is common among the general population and among colleagues within the department, and hence "normal." Also interesting was that the helix of the ear chosen as the most aesthetic was also the ear where the helix was almost touching the side of the head. We found that when judging the aesthetic nature of the "virgin" ear, antihelical fold prominence did not appear to be a negative attribute. Indeed, we noted that a prominent antihelix was a common attribute, and we conclude that this was a normal variant without undue negative aesthetic stigma. A surgically corrected ear should not necessarily be regarded as a poor outcome simply on the basis of antihelical prominence. Furthermore, we postulate that patients who have a prominent antihelix might be part of a spectrum of individuals who might have had the subtype of prominent ears featuring a deep conchal bowl. Finally, although not tested directly, it appears that we do not have an idea of our own ear shape, as none of the

  19. Chondrocutaneous helix rim advancement flap: two classical and two new modifications for very large defects of the ear.

    PubMed

    Valesky, E M; Kaufmann, R; Meissner, M

    2015-11-01

    The plastic reconstruction of the ear after microscopically controlled tumor surgery is a particular challenge. The chondrocutaneous helix rim advancement flap (CHRAF) is perfectly suited for the repair of different defects of the helix and even defects beyond. Here, we describe two known and two new modifications of the CHRAF that enlarge the scope of application in tumor surgery of the ear. We demonstrate the different techniques and practical application of the repair and evaluate the benefits and limitations. The CHRAF and its modifications is an excellent method for repair of various defects of the helical region of the ear. The CHRAF and its modifications proves to be an good alternative to other methods of closure by preserving the anatomical contour and mechanical and acoustic functions in a single-staged procedure with excellent aesthetic results. The two new modifications we introduced here, enlarge the known armentarium for very large defects of the upper pole and the mid-helix of the ear. © 2014 European Academy of Dermatology and Venereology.

  20. Mirror ear: a reconstructive technique for substantial tragal anomalies or polyotia.

    PubMed

    Gore, Sinclair M; Myers, Simon R; Gault, David

    2006-01-01

    Polyotia (mirror ear) is an extremely rarely reported congenital anomaly of the external ear. The aetiology of this condition is unclear, and there are few descriptions of surgical techniques used. We aimed to review our experience with this condition by performing a retrospective review of the cases treated in our unit. Eight cases of polyotia treated at a referral centre for ear reconstruction in a 12 year period (1992-2004) were reviewed. Patient demographic data and associated syndromes were recorded. Operative techniques used in the cases were studied. There was an equal number of males and females. Four patients had abnormal contralateral ears and two patients were formally diagnosed as suffering from a congenital developmental syndrome. Five main components of surgical technique were found to be particularly relevant to these cases. These relate to deconstruction of the defect, management of extra cartilage, management of skin, proximity of the facial nerve and the timing of surgery. The authors conclude that a structured surgical approach can lead to successful reconstruction of these difficult abnormalities.

  1. Microsurgical ear replantation-is venous repair necessary?-A systematic review.

    PubMed

    Momeni, Arash; Liu, Xiangxia; Januszyk, Michael; Wan, Derrick C; Buncke, Gregory M; Buntic, Rudolf F; Parrett, Brian M

    2016-05-01

    A common postoperative observation after microsurgical ear replantation has been venous congestion necessitating alternate modes of decongestion, frequently in conjunction with blood transfusion. A comprehensive literature search was performed to assess the relationship between mode of vascular reconstruction and postoperative outcome as well as postoperative transfusion requirement after microsurgical ear replantation. The search was limited to cases of microsurgical ear replantation following complete amputation. Only articles published in English and indexed in PubMed were included. The initial search retrieved 285 articles, which was narrowed down to 40 articles reporting on 60 cases that matched the aforementioned criteria. Reconstruction of the arterial and venous limb (Group 1) was performed in 63.3% of patients and artery-only anastomosis (Group 2) was performed in 31.7%. Among measurable outcomes, only the duration of surgery was significantly different between groups (2.6 hours longer in Group 1 than Group 2; P = 0.0042). In light of contemporary data demonstrating successful artery-only ear replantation, replantation should not be abandoned when unable to establish venous outflow microsurgically. © 2015 Wiley Periodicals, Inc. Microsurgery 36:345-350, 2016. © 2015 Wiley Periodicals, Inc.

  2. Ear asymmetries in middle-ear, cochlear, and brainstem responses in human infants

    PubMed Central

    Keefe, Douglas H.; Gorga, Michael P.; Jesteadt, Walt; Smith, Lynette M.

    2008-01-01

    In 2004, Sininger and Cone-Wesson examined asymmetries in the signal-to-noise ratio (SNR) of otoacoustic emissions (OAE) in infants, reporting that distortion-product (DP)OAE SNR was larger in the left ear, whereas transient-evoked (TE)OAE SNR was larger in the right. They proposed that cochlear and brainstem asymmetries facilitate development of brain-hemispheric specialization for sound processing. Similarly, in 2006 Sininger and Cone-Wesson described ear asymmetries mainly favoring the right ear in infant auditory brainstem responses (ABRs). The present study analyzed 2640 infant responses to further explore these effects. Ear differences in OAE SNR, signal, and noise were evaluated separately and across frequencies (1.5, 2, 3, and 4 kHz), and ABR asymmetries were compared with cochlear asymmetries. Analyses of ear-canal reflectance and admittance showed that asymmetries in middle-ear functioning did not explain cochlear and brainstem asymmetries. Current results are consistent with earlier studies showing right-ear dominance for TEOAE and ABR. Noise levels were higher in the right ear for OAEs and ABRs, causing ear asymmetries in SNR to differ from those in signal level. No left-ear dominance for DPOAE signal was observed. These results do not support a theory that ear asymmetries in cochlear processing mimic hemispheric brain specialization for auditory processing. PMID:18345839

  3. A review of virtual reality based training simulators for orthopaedic surgery.

    PubMed

    Vaughan, Neil; Dubey, Venketesh N; Wainwright, Thomas W; Middleton, Robert G

    2016-02-01

    This review presents current virtual reality based training simulators for hip, knee and other orthopaedic surgery, including elective and trauma surgical procedures. There have not been any reviews focussing on hip and knee orthopaedic simulators. A comparison of existing simulator features is provided to identify what is missing and what is required to improve upon current simulators. In total 11 hip replacements pre-operative planning tools were analysed, plus 9 hip trauma fracture training simulators. Additionally 9 knee arthroscopy simulators and 8 other orthopaedic simulators were included for comparison. The findings are that for orthopaedic surgery simulators in general, there is increasing use of patient-specific virtual models which reduce the learning curve. Modelling is also being used for patient-specific implant design and manufacture. Simulators are being increasingly validated for assessment as well as training. There are very few training simulators available for hip replacement, yet more advanced virtual reality is being used for other procedures such as hip trauma and drilling. Training simulators for hip replacement and orthopaedic surgery in general lag behind other surgical procedures for which virtual reality has become more common. Further developments are required to bring hip replacement training simulation up to date with other procedures. This suggests there is a gap in the market for a new high fidelity hip replacement and resurfacing training simulator. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. A randomized controlled trial of simulation-based training for ear, nose, and throat emergencies.

    PubMed

    Smith, Matthew Edward; Navaratnam, Annakan; Jablenska, Lily; Dimitriadis, Panagiotis A; Sharma, Rishi

    2015-08-01

    Life-threatening ear, nose, and throat (ENT) emergencies are uncommon but require immediate skilled management. We investigated if traditional lecture-based teaching can be improved by a simulation and lecture hybrid approach. A single-blinded, prospective, randomized controlled trial. Two groups of interns with no previous ENT experience were randomized to one of two training groups: a simulation/lecture hybrid group or a lecture-only control group. Both groups received 90 minutes of training covering the assessment of critically ill patients and four ENT emergency topics. Both groups received the same initial lecture slides. The control group received additional slides, and the simulation group received simulated emergency scenario training using basic mannequins. Following the training, candidates were asked to provide feedback on their perception of training, and they were formally assessed with a standardized one-to-one viva. Thirty-eight interns were recruited: 18 in the control group and 20 in the simulation group. The candidates in the simulation group performed significantly better in all viva situations (P < .05) and had better perception of learning (P < .05). Additionally, the simulation group was more likely to recommend the training to a colleague (P < .05). We have demonstrated that replacing traditional lecture-based training with a mixture of lectures and emergency scenario simulation is more effective at preparing junior doctors for ENT emergencies, and better met their learning needs. Implementing this kind of teaching is feasible with a minimum of additional resources or time. 1b © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Corpus callosum functioning in patients with normal pressure hydrocephalus before and after surgery.

    PubMed

    Mataró, Maria; Poca, Maria Antonia; Matarín, Mar; Sahuquillo, Juan; Sebastián, Nuria; Junqué, Carme

    2006-05-01

    Our aim was to evaluate corpus callosum functioning in a group of patients with normal pressure hydrocephalus (NPH) before and after shunting. Left ear-extinction under a dichotic listening task was evaluated in twenty-three patients with NPH, 30 patients with Alzheimer's disease and 30 aged controls. Patients with NPH had higher levels of left ear extinction than the control and Alzheimer's groups. Sixty-one percent of NPH patients exhibited left ear suppression, compared with 13% of Alzheimer's patients and 17% of controls. Following surgery, NPH patients showed a significant change in the degree of asymmetry in the dichotic listening task. Hydrocephalus was associated with left-ear extinction,which diminished after surgery. Our results may indicate reversible functional damage in the corpus callosum.

  6. Bone Marrow Stem Cells and Ear Framework Reconstruction.

    PubMed

    Karimi, Hamid; Emami, Seyed-Abolhassan; Olad-Gubad, Mohammad-Kazem

    2016-11-01

    Repair of total human ear loss or congenital lack of ears is one of the challenging issues in plastic and reconstructive surgery. The aim of the present study was 3D reconstruction of the human ear with cadaveric ear cartilages seeded with human mesenchymal stem cells. We used cadaveric ear cartilages with preserved perichondrium. The samples were divided into 2 groups: group A (cartilage alone) and group B (cartilage seeded with a mixture of fibrin powder and mesenchymal stem cell [1,000,000 cells/cm] used and implanted in back of 10 athymic rats). After 12 weeks, the cartilages were removed and shape, size, weight, flexibility, and chondrocyte viability were evaluated. P value <0.05 was considered significant. In group A, size and weight of cartilages clearly reduced (P < 0.05) and then shape and flexibility (torsion of cartilages in clockwise and counterclockwise directions) were evaluated, which were found to be significantly reduced (P > 0.05). After staining with hematoxylin and eosin and performing microscopic examination, very few live chondrocytes were found in group A. In group B, size and weight of samples were not changed (P < 0.05); the shape and flexibility of samples were well maintained (P < 0.05) and on performing microscopic examination of cartilage samples, many live chondrocytes were found in cartilage (15-20 chondrocytes in each microscopic field). In samples with human stem cell, all variables (size, shape, weight, and flexibility) were significantly maintained and abundant live chondrocytes were found on performing microscopic examination. This method may be used for reconstruction of full defect of auricles in humans.

  7. Swimmer's Ear (For Parents)

    MedlinePlus

    ... scratching the ear canal, vigorous ear cleaning with cotton swabs, or putting foreign objects like bobby pins ... Also, never put objects into kids' ears, including cotton-tipped swabs. How Is Swimmer's Ear Treated? Treatment ...

  8. Tail Docking and Ear Cropping Dogs: Public Awareness and Perceptions

    PubMed Central

    Mills, Katelyn E.; Robbins, Jesse; von Keyserlingk, Marina A. G.

    2016-01-01

    Tail docking and ear cropping are two surgical procedures commonly performed on many dog breeds. These procedures are classified as medically unnecessary surgeries whose purpose is primarily cosmetic. Available attitude research surrounding these controversial practices has been limited to surveys of veterinarians and dog breeders familiar with both practices. The aim of this project was to: 1) assess public awareness of tail docking and ear cropping, 2) determine whether physical alteration of a dog affects how the dog, and 3) owner are perceived. In Experiment 1 awareness was measured using a combination of both explicit and implicit measures. We found that 42% of participants (n = 810) were unable to correctly explain the reason why tail docked and ear cropped dogs had short ears and tails. Similarly, an implicit measure of awareness (‘nature vs nurture task’), found that the majority of participants believed short tails and erect ears were a consequence of genetics rather than something the owner or breeder had done. The results obtained in Experiment 2 (n = 392) provide evidence that ear cropped and tail docked dogs are perceived differently than an identical dog in its ‘natural’ state. Modified dogs were perceived as being more aggressive, more dominant, less playful and less attractive than natural dogs. Experiment 3 (n = 410) is the first evidence that owners of modified dogs are perceived as being more aggressive, more narcissistic, less playful, less talkative and less warm compared to owners of natural dogs. Taken together, these results suggest that although a significant proportion of subjects appear unaware of the practices of tail docking and ear cropping in dogs, these procedures have significant impacts on how modified dogs and their owners are perceived by others. PMID:27348817

  9. Tail Docking and Ear Cropping Dogs: Public Awareness and Perceptions.

    PubMed

    Mills, Katelyn E; Robbins, Jesse; von Keyserlingk, Marina A G

    2016-01-01

    Tail docking and ear cropping are two surgical procedures commonly performed on many dog breeds. These procedures are classified as medically unnecessary surgeries whose purpose is primarily cosmetic. Available attitude research surrounding these controversial practices has been limited to surveys of veterinarians and dog breeders familiar with both practices. The aim of this project was to: 1) assess public awareness of tail docking and ear cropping, 2) determine whether physical alteration of a dog affects how the dog, and 3) owner are perceived. In Experiment 1 awareness was measured using a combination of both explicit and implicit measures. We found that 42% of participants (n = 810) were unable to correctly explain the reason why tail docked and ear cropped dogs had short ears and tails. Similarly, an implicit measure of awareness ('nature vs nurture task'), found that the majority of participants believed short tails and erect ears were a consequence of genetics rather than something the owner or breeder had done. The results obtained in Experiment 2 (n = 392) provide evidence that ear cropped and tail docked dogs are perceived differently than an identical dog in its 'natural' state. Modified dogs were perceived as being more aggressive, more dominant, less playful and less attractive than natural dogs. Experiment 3 (n = 410) is the first evidence that owners of modified dogs are perceived as being more aggressive, more narcissistic, less playful, less talkative and less warm compared to owners of natural dogs. Taken together, these results suggest that although a significant proportion of subjects appear unaware of the practices of tail docking and ear cropping in dogs, these procedures have significant impacts on how modified dogs and their owners are perceived by others.

  10. [Three-dimensional display simulation of lung surgery using "active shutter glasses"].

    PubMed

    Onuki, Takamasa; Kanzaki, Masato; Sakamoto, Kei; Kikkawa, Takuma; Isaka, Tamami; Shimizu, Toshihide; Oyama, Kunihiro; Murasugi, Masahide

    2011-08-01

    We have reported preoperative 3-dimensional (3D) simulation of thoracoscopic lung surgery using self-made software and internet shareware of 3D-modeler. Using "active shutter glasses", we have tried the "3D display simulation" of lung surgery. 3D display was more effective to grasp clear 3D interrelation between the bronchii and pulmonary vascular system than those in images of currently in use with the same information volume.

  11. Middle ear tuberculosis: diagnostic criteria.

    PubMed

    Jesić, Snezana; Stosić, Svetlana; Milenković, Branislava; Nesić, Vladimir; Dudvarski, Zoran; Jotić, Ana; Slijepcević, Nikola

    2009-01-01

    Tuberculous otitis is a diagnostic problem due to the difficulty to obtain microbiological, histomorphological and cytological confirmation of the disease. Our objective was to compare clinical and radiological characteristic and development of otogenic complications in patients with tuberculous otitis and otitis with cholesteatoma as the most destructive form of chronic nonspecific otitis in the purpose of establishing the diagnostic criteria for tuberculous otitis. Medical records of 12 patients with tuberculous otitis and 163 patients with cholesteatoma treated at the Institute of Otorhinolaryngology and Maxillofacial Surgery in Belgrade during the eight-year period were analyzed. All of the patients underwent otomicroscopic, audiological and radiological examination of the thorax and temporal bone, microbiological examination of the secretion and histomorphological examination of the tissue taken during middle ear surgery. Statistical analysis was done using chi2 test with Yates correction. Otogenic complication as facial palsy and sensorineural hearing loss were more frequent in tuberculous otitis patients, than in cholesteatoma. Also, fistulas of the labyrinth and facial canal bone destruction were also more frequent in tuberculous otitis than in cholesteatoma. A larger extent of temporal bone destruction was noticed on CT scans of the temporal bone in half of the patents with tuberculous otitis. Coexistence with miliary pulmonary tuberculosis was detected in one third of the patients. There were no microbiological or histomorphological confirmations of the disease, except in one case with positive ZiehI-Neelsen staining. Tuberculous otitis media should be considered in patients with serious otogenic complications and with shorter duration of ear discharge, and in association with diagnosed miliary pulmonary tuberculosis and extensive temporal bone destruction. Polymerase chain reaction still is not reliable for diagnosis.

  12. [Analysis of psychosocial changes following ear reconstruction with rib cartilage - development of a short test].

    PubMed

    Steffen, A; Meyer Zu Natrup, C; König, I R; Frenzel, H; Rotter, N

    2009-04-01

    The improvement of psychosocial well being in patients with microtia after ear reconstruction with rib cartilage is mainly assessed clinically. There are first prospective studies with established psychological questionnaires showing promising results but these tests are too extensive for everyday-use in clinical routine. Therefore, we examined a self-designed short version for the specific use in the head-neck-region. The clinically established psychological questionnaire "Frankfurter Selbstkonzeptskalen/FSKN" consists of 78 items for self-assessment of performance abilities, self-esteem, and psychosocial attitude. We downsized the FSKN to 13 items that might be relevant for plastic reconstructive surgery in the head-neck-region. The pre- and postoperative development after ear reconstruction with rib cartilage was analyzed retrospectively in 68 patients and prospectively in 21 patients. The preoperative data of the prospective study group were compared with the results of 23 patients with microtia who declined any type of reconstruction after consultation. Especially the results of the psychosocial competence improved after ear reconstruction as well in the retrospective (median values 138,5 to points; p<0,01) as well as in the prospective study group (median values 126 to 141 points; p=0,01). We were able to demonstrate changes in the short version of the FSKN (median values 51,5 to 58,5 points; p<0,01 respectively, 50 to 56 points; p=0,02). Patients who declined ear surgery showed higher values in psychosocial competence (median values 126 to 154 points; p<0,01). Again, the short form displayed this difference clearly (median values 50 to 65 points; p<0,01). The short version of the FSKN has promising potential for the preoperative assessment and the documentation of psychological changes following reconstructive surgery. Further studies are necessary to validate the new instrument to obtain a valuable test for use in clinical routine in plastic surgery in the

  13. Middle ear findings and need for ventilation tubes among pediatric cleft lip and palate patients in northern Finland.

    PubMed

    Lehtonen, Ville; Lithovius, Riitta H; Autio, Timo J; Sándor, George K; Ylikontiola, Leena P; Harila, Virpi; Pesonen, Paula; Koskinen, Sari; Anttonen, Vuokko

    2016-04-01

    Middle ear problems are common in cleft patients. This study aimed to determine the need for ventilation tubes (VTs) and complications such as tympanic perforation and cholesteatoma. Data of 156 children with clefts managed in northern Finland spanning 15 years from 1997 to 2011 were collected from 6 hospitals. The following were recorded: birth date, gender, cleft type, surgery timing, surgery type, number of tube insertions, tube material, middle ear findings, and tube placement timing. Clefts were divided into 4 groups: cleft palate (CP), cleft lip and palate (CLP), cleft lip (CL), and submucous cleft palate. The prevalence of middle ear findings was reported. Mucous secretion was noted in 96.8% of CLP patients, 69.2% of CP patients, and 13.0% of CL patients. In all, 82.7% of study group had 1 or more VTs placed during follow-up. All CLP patients required more than 1 VT placement. A total of 94.5% of CP patients required VTs compared to 13.0% of CL patients. In the presence of residual oral nasal fistula, the mean number of tube insertions was 5.3. The prevalence of tympanic perforations in clefts was 35.9% and cholesteatoma in 2.6% of patients. CLP and isolated CP patients have frequent middle ear infections requiring multiple VT placements. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Student perception of two different simulation techniques in oral and maxillofacial surgery undergraduate training.

    PubMed

    Lund, Bodil; Fors, Uno; Sejersen, Ronny; Sallnäs, Eva-Lotta; Rosén, Annika

    2011-10-12

    Yearly surveys among the undergraduate students in oral and maxillofacial surgery at Karolinska Institutet have conveyed a wish for increased clinical training, and in particular, in surgical removal of mandibular third molars. Due to lack of resources, this kind of clinical supervision has so far not been possible to implement. One possible solution to this problem might be to introduce simulation into the curriculum. The purpose of this study was to investigate undergraduate students' perception of two different simulation methods for practicing clinical reasoning skills and technical skills in oral and maxillofacial surgery. Forty-seven students participating in the oral and maxillofacial surgery course at Karolinska Institutet during their final year were included. Three different oral surgery patient cases were created in a Virtual Patient (VP) Simulation system (Web-SP) and used for training clinical reasoning. A mandibular third molar surgery simulator with tactile feedback, providing hands on training in the bone removal and tooth sectioning in third molar surgery, was also tested. A seminar was performed using the combination of these two simulators where students' perception of the two different simulation methods was assessed by means of a questionnaire. The response rate was 91.5% (43/47). The students were positive to the VP cases, although they rated their possible improvement of clinical reasoning skills as moderate. The students' perception of improved technical skills after training in the mandibular third molar surgery simulator was rated high. The majority of the students agreed that both simulation techniques should be included in the curriculum and strongly agreed that it was a good idea to use the two simulators in concert. The importance of feedback from the senior experts during simulator training was emphasised. The two tested simulation methods were well accepted and most students agreed that the future curriculum would benefit from

  15. Proposal of a Classification System for the Assessment and Treatment of Prominent Ear Deformity.

    PubMed

    Lee, Youngdae; Kim, Young Seok; Lee, Won Jai; Rha, Dong Kyun; Kim, Jiye

    2018-06-01

    Prominent ear is the most common external ear deformity. To comprehensively treat prominent ear deformity, adequate comprehension of its pathophysiology is crucial. In this article, we analyze cases of prominent ear and suggest a simple classification system and treatment algorithm according to pathophysiology. We retrospectively reviewed a total of 205 Northeast Asian patients' clinical data who underwent an operation for prominent ear deformity. Follow-up assessments were conducted 3, 6, and 12 months after surgery. Prominent ear deformities were classified by diagnostic checkpoints. Class I (simple prominent ear) includes prominent ear that developed with the absence of the antihelix without conchal hypertrophy. Class II (mixed-type prominent ear) is defined as having not only a flat antihelix, but also conchal excess. Class III (conchal-type prominent ear) has an enlarged conchal bowl with a well-developed antihelix. Among the three types of prominent ear, class I was most frequent (162 patients, 81.6%). Class II was observed in 28 patients (13.6%) and class III in 10 patients (4.8%). We used the scaphomastoid suture method for correction of antihelical effacement, the anterior approach conchal resection for correction of conchal hypertrophy, and Bauer's squid incision for lobule prominence. The complication rate was 9.2% including early hematoma, hypersensitivity, and suture extrusion. Unfavorable results occurred in 4% including partial recurrence, overcorrection, and undercorrection. To reduce unfavorable results and avoid recurrence, we propose the use of a classification and treatment algorithm in preoperative evaluation of prominent ear. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  16. Expansion method in secondary total ear reconstruction for undesirable reconstructed ear.

    PubMed

    Liu, Tun; Hu, Jintian; Zhou, Xu; Zhang, Qingguo

    2014-09-01

    Ear reconstruction by autologous costal cartilage grafting is the most widely applied technique with fewer complications. However, undesirable ear reconstruction brings more problems to plastic surgeons. Some authors resort to free flap or osseointegration technique with prosthetic ear. In this article, we introduce a secondary total ear reconstruction with expanded skin flap method. From July 2010 to April 2012, 7 cases of undesirable ear reconstruction were repaired by tissue expansion method. Procedures including removal of previous cartilage framework, soft tissue expander insertion, and second stage of cartilage framework insertion were performed to each case regarding their local conditions. The follow-up time ranged from 6 months to 2.5 years. All of the cases recovered well with good 3-dimensional forms, symmetrical auriculocephalic angle, and stable fixation. All these evidence showed that this novel expansion method is safe, stable, and less traumatic for secondary total ear reconstruction. With sufficient expanded skin flap and refabricated cartilage framework, lifelike appearance of reconstructed ear could be acquired without causing additional injury.

  17. PubMed Central

    LINKE, R.; LEICHTLE, A.; SHEIKH, F.; SCHMIDT, C.; FRENZEL, H.; GRAEFE, H.; WOLLENBERG, B.; MEYER, J.E.

    2013-01-01

    SUMMARY Surgery on the temporal bone is technically challenging due to its complex anatomy. Precise anatomical dissection of the human temporal bone is essential and is fundamental for middle ear surgery. We assessed the possible application of a virtual reality temporal bone surgery simulator to the education of ear surgeons. Seventeen ENT physicians with different levels of surgical training and 20 medical students performed an antrotomy with a computer-based virtual temporal bone surgery simulator. The ease, accuracy and timing of the simulated temporal bone surgery were assessed using the automatic assessment software provided by the simulator device and additionally with a modified Final Product Analysis Scale. Trained ENT surgeons, physicians without temporal bone surgical training and medical students were all able to perform the antrotomy. However, the highly trained ENT surgeons were able to complete the surgery in approximately half the time, with better handling and accuracy as assessed by the significant reduction in injury to important middle ear structures. Trained ENT surgeons achieved significantly higher scores using both dissection analysis methods. Surprisingly, there were no significant differences in the results between medical students and physicians without experience in ear surgery. The virtual temporal bone training system can stratify users of known levels of experience. This system can be used not only to improve the surgical skills of trained ENT surgeons for more successful and injury-free surgeries, but also to train inexperienced physicians/medical students in developing their surgical skills for the ear. PMID:24043916

  18. Surgical correction of constricted ear combined with Stahl's ear.

    PubMed

    Bi, Ye; Lin, Lin; Yang, Qinhua; Pan, Bo; Zhao, Yanyong; He, Leren; Jiang, Haiyue

    2015-07-01

    Constricted ear combined with Stahl's ear is a rare ear deformity, which is a kind of complex congenital auricular deformity. From 1 January 2007 to 1 January 2014, 19 patients with constricted ear combined with Stahl's ear (Spock ear) were enrolled in this study, most of which were unilaterally deformed. To correct the deformity, a double Z-shaped skin incision was made on the posterior side of the auricle, with the entire layer of cartilage cut parallel to the helix traversing the third crus to form a fan-shaped cartilage flap. The superior crura of the antihelix were shaped by the folding cartilage rim. The cartilage of the abnormal third crus was made part of the new superior crura of antihelix, and the third crus was eliminated. The postoperative aesthetic assessment of the reshaped auricle was graded by both doctors and patients (or their parents). Out of the 19 patients, the number of satisfying cases of the symmetry, helix stretch, elimination of the third crus, the cranioauricular angle, and the substructure of the reshaped ears was 14 (nine excellent and five good), 16 (six excellent and 10 good), 17 (eight excellent and nine good), 15 (five excellent and 10 good), and 13 (two excellent and 11 good), respectively. With a maximum of a 90-month follow-up, no complication was observed. The results of the study suggested that this rare deformity could be corrected by appropriate surgical treatment, with a satisfied postoperative appearance. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. Elephant ear

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/002867.htm Elephant ear poisoning To use the sharing features on this page, please enable JavaScript. Elephant ear plants are indoor or outdoor plants with ...

  20. Treatment of Prominent Ears with an Implantable Clip System: A Pilot Study.

    PubMed

    Kang, Norbert V; Kerstein, Ryan L

    2016-03-01

    The earFold™ implantable clip system is a new treatment for prominent ears using an implant made from nickel-titanium alloy, forged into a predetermined shape. The implant is fixed to the cartilage then released, causing the cartilage to fold back. The study aimed to test the safety and behaviour of the implant in vivo. This was a Phase 1, prospective, nonrandomised study. Thirty-nine patients were recruited, from 7 to 57 years of age (22 adults and 17 children). Thirty-seven patients were followed up for a minimum of 18 months. A total of 131 implants was used to treat 75 ears. All treatments were performed under local anaesthetic. Eighteen patients asked for their implants to be left in place permanently. Twenty-one patients agreed to have their implants removed at 6, 12, or 18 months after insertion. Complications affected 8 patients and included extrusion, infection, hypertrophic scarring, and Spock-ear formation. No new complications have arisen in any of the patients since the conclusion of the study, up to a maximum of 47 months. Patients were overwhelmingly satisfied with the outcome of treatment. earFold can be used as a permanent implant to correct prominence of the human ear. It is best suited for treating prominent ears with a poorly formed or absent antihelical fold. The procedure is quick and predictable with a complication rate comparable to suture-based otoplasty techniques. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  1. [SOX10 mutation is relevant to inner ear malformation in patients with Waardenburg syndrome].

    PubMed

    Xu, G Y; Hao, Q Q; Zhong, L L; Ren, W; Yan, Y; Liu, R Y; Li, J N; Guo, W W; Zhao, H; Yang, S M

    2016-11-07

    Objective: To determine the relevance between the SOX 10 mutation and Waardenburg syndrome (WS) accompanied with inner ear abnormality by analyzing the inner ear imaging results and molecular and genetic results of the WS patients with the SOX 10 mutation. Methods: This study included 36 WS in patients during 2001 and 2015 in the department of otorhinolaryngology head and neck surgery, Chinese Peoples's Liberation Army General Hospital. The condition of the inner ear of each patient was assessed by analyzing HRCT scans of the temporal bone and MRI scans of the brain and internal auditory canal. Meanwhile, the possible pathogenic genes of WS, including SOX10, MITF , and PAX 3, were also screened. Patients were divided into two groups according to SOX 10 mutation.The Fisher accuracy test was used to determine statistical difference of inner ear deformation incidence between the two groups. Results: Among all 36 patients, 12 were found to have inner ear abnormality. Most abnormalities were posterior semicircular canal deformations, some accompanied with cochlear deformation and an enlarged vestibule. Among all patients, 9 patients were SOX 10 heterozygous mutation carriers, among which six showed bilateral inner ear abnormality. Fisher accuracy test results suggested a significant correlation between the SOX 10 mutation and inner ear abnormality in WS patients ( P =0.036). Conclusion: This study found that WS patients with the SOX 10 mutation are more likely to have deformed inner ears when compared to WS patients without the SOX 10 mutation.

  2. Validation of Robotic Surgery Simulator (RoSS).

    PubMed

    Kesavadas, Thenkurussi; Stegemann, Andrew; Sathyaseelan, Gughan; Chowriappa, Ashirwad; Srimathveeravalli, Govindarajan; Seixas-Mikelus, Stéfanie; Chandrasekhar, Rameella; Wilding, Gregory; Guru, Khurshid

    2011-01-01

    Recent growth of daVinci Robotic Surgical System as a minimally invasive surgery tool has led to a call for better training of future surgeons. In this paper, a new virtual reality simulator, called RoSS is presented. Initial results from two studies - face and content validity, are very encouraging. 90% of the cohort of expert robotic surgeons felt that the simulator was excellent or somewhat close to the touch and feel of the daVinci console. Content validity of the simulator received 90% approval in some cases. These studies demonstrate that RoSS has the potential of becoming an important training tool for the daVinci surgical robot.

  3. Surgeon Training in Telerobotic Surgery via a Hardware-in-the-Loop Simulator

    PubMed Central

    Alemzadeh, Homa; Chen, Daniel; Kalbarczyk, Zbigniew; Iyer, Ravishankar K.; Kesavadas, Thenkurussi

    2017-01-01

    This work presents a software and hardware framework for a telerobotic surgery safety and motor skill training simulator. The aims are at providing trainees a comprehensive simulator for acquiring essential skills to perform telerobotic surgery. Existing commercial robotic surgery simulators lack features for safety training and optimal motion planning, which are critical factors in ensuring patient safety and efficiency in operation. In this work, we propose a hardware-in-the-loop simulator directly introducing these two features. The proposed simulator is built upon the Raven-II™ open source surgical robot, integrated with a physics engine and a safety hazard injection engine. Also, a Fast Marching Tree-based motion planning algorithm is used to help trainee learn the optimal instrument motion patterns. The main contributions of this work are (1) reproducing safety hazards events, related to da Vinci™ system, reported to the FDA MAUDE database, with a novel haptic feedback strategy to provide feedback to the operator when the underlying dynamics differ from the real robot's states so that the operator will be aware and can mitigate the negative impact of the safety-critical events, and (2) using motion planner to generate semioptimal path in an interactive robotic surgery training environment. PMID:29065635

  4. Airplane Ear

    MedlinePlus

    ... to severe hearing loss Ringing in your ear (tinnitus) Spinning sensation (vertigo) Vomiting resulting from vertigo Bleeding ... complications may include: Permanent hearing loss Ongoing (chronic) tinnitus Prevention Follow these tips to avoid airplane ear: ...

  5. Your Ears

    MedlinePlus

    ... Protect your hearing by wearing earplugs at loud music concerts and around noisy machinery, like in wood ... More on this topic for: Kids Can Loud Music Hurt My Ears? What Is an Ear Infection? ...

  6. Ear examination

    MedlinePlus

    ... ear anatomy Otoscopic exam of the ear References King EF, Couch ME. History, physical examination, and the ... commercial use must be authorized in writing by ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer ...

  7. Inner ear disorders.

    PubMed

    Smouha, Eric

    2013-01-01

    To present a framework for the diagnosis and treatment of inner ear disorders, with an emphasis on problems common to neuro-rehabilitation. Disorders of the inner ear can cause hearing loss, tinnitus, vertigo and imbalance. Hearing loss can be conductive, sensorineural, or mixed; conductive hearing loss arises from the ear canal or middle ear, while sensorineural hearing loss arises from the inner ear or auditory nerve. Vertigo is a hallucination of motion, and is the cardinal symptom of vestibular system disease. It should be differentiated from other causes of dizziness: gait imbalance, disequilibrium, lightheadedness (pre-syncope). Vertigo can be caused by problems in the inner ear or central nervous system. The diagnosis of inner ear disorders begins with a targeted physical examination. The initial work-up of hearing loss is made by audiometry, and vertigo by electronystagmography (ENG). Supplemental tests and MRI are obtained when clinically indicated. The clinical pattern and duration of vertigo are the most important clinical features in the diagnosis. Common inner ear causes of vertigo include: vestibular neuritis (sudden, unilateral vestibular loss), Meniere's disease (episodic vertigo), benign paroxysmal positional vertigo (BPPV), and bilateral vestibular loss. Common central nervous system causes of vertigo include: post concussion syndrome, cervical vertigo, vestibular migraine, cerebrovascular disease, and acoustic neuroma. A basic knowledge of vestibular physiology, coupled with a understanding of common vestibular syndromes, will lead to correct diagnosis and treatment in most cases.

  8. Comparison of two incisionless otoplasty techniques for prominent ears in children.

    PubMed

    Haytoglu, Suheyl; Haytoglu, Tahir Gokhan; Bayar Muluk, Nuray; Kuran, Gokhan; Arikan, Osman Kursat

    2015-04-01

    In the present study, we applied two incisionless suture techniques for otoplasty: Haytoglu et al.'s modification of incisionless otoplasty technique and Fritsch's incisionless otoplasty technique for correction of prominent ears. In this prospective study, 60 patients with prominent ears were included in the study. In Group 1, 55 ears of 30 patients (25 bilateral and 5 unilateral) were operated with Haytoglu et al.'s modification of incisionless otoplasty technique. In Group 2, 57 ears of 30 patients (27 bilateral and 3 unilateral) were operated with Fritsch's incisionless otoplasty technique. For comparison of two methods, auriculocephalic distances were measured at three levels which were level 1 (the most superior point of the auricle), level 2 (the midpoint of the auricle) and level 3 (level of the lobule) pre-operatively (preop); and measurements were repeated at the end of the surgery (PO(0-day)), 1st month (PO(1-Mo)) and 6th month (PO(6-Mo)) after the surgery, in both groups. Patient satisfaction was evaluated using a visual analog scale (VAS). Moreover, Global Aesthetic Improvement Scale (GAIS) was rated by an independent, non-participating plastic surgeon at 6 months after the surgery. Operation time was 15.9±5.6min in Group 1 (Haytoglu et al.'s) and 19±4.7min in Group 2 (Fritsch). Hematoma, infection, bleeding, keloid scar formation, sharp edges or irregularities of the cartilage were not observed in any group. Suture extrusion was detected in 14.03% of Group 1 and 16.1% of Group 2. No statistically significant difference was observed between auriculocephalic distances at levels 1-3 of groups at preop, PO(0-day), PO(1-Mo) and PO(6-Mo) separately. Similarly, difference in auriculocephalic distances (preop values-PO(6-Mo) values) was not detected as statistically significant in Groups 1 and 2 at three levels. In both techniques, No statistically significant difference was observed in patient satisfaction at 6th months after the operation which was

  9. Simulated life-threatening emergency during robot-assisted surgery.

    PubMed

    Huser, Anna-Sophia; Müller, Dirk; Brunkhorst, Violeta; Kannisto, Päivi; Musch, Michael; Kröpfl, Darko; Groeben, Harald

    2014-06-01

    With the increasing use of robot-assisted techniques for urologic and gynecologic surgery in patients with severe comorbidities, the risk of a critical incidence during surgery increases. Due to limited access to the patient the start of effective measures to treat a life-threatening emergency could be delayed. Therefore, we tested the management of an acute emergency in an operating room setting with a full-size simulator in six complete teams. A full-size simulator (ISTAN, Meti, CA), modified to hold five trocars, was placed in a regular operating room and connected to a robotic system. Six teams (each with three nurses, one anesthesiologist, two urologists or gynecologists) were introduced to the scenario. Subsequently, myocardial fibrillation occurred. Time to first chest compression, removal of the robot, first defibrillation, and stabilization of circulation were obtained. After 7 weeks the simulation was repeated. The time to the start of chest compressions, removal of the robotic system, and first defibrillation were significantly improved at the second simulation. Time for restoration of stable circulation was improved from 417 ± 125 seconds to 224 ± 37 seconds (P=0.0054). Unexpected delays occurred during the first simulation because trocars had been removed from the patient but not from the robot, thus preventing the robot to be moved. Following proper training, resuscitation can be started within seconds. A repetition of the simulation significantly improved time for all steps of resuscitation. An emergency simulation of a multidisciplinary team in a real operating room setting can be strongly recommended.

  10. Ear epistheses as an alternative to autogenous reconstruction.

    PubMed

    Federspil, Philipp A

    2009-08-01

    An ear episthesis is an artificial substitute for the auricle. The term EAR PROSTHESIS is used synonymously. The breakthrough came with the introduction of the modern silicones and their colorings. Although there are still indications for noninvasive methods of retention such as medical adhesives, the best and most reliable method of fixation is by bone anchorage. Long-lasting osseointegration with reaction-free skin penetration can be achieved with titanium implants. The first system used extraorally was the Brånemark flange fixture. Later, different solitary titanium implants were introduced, such as the ITI system. A different strategy used the titanium grids (Epitec) or plates (Epiplating) derived from osteosynthesis systems. These systems are fixed subperiosteally with several bone screws and are therefore also labeled as grouped implants. With these modern developments, secure retention can be achieved also in unfavorable anatomic situations. The grouped systems are resistant to torque with abutment insertion. The latest development is the subcutaneously implanted double magnet without skin penetration. The advantages of implant retained ear epistheses include optimal camouflage, predictable cosmetic results, fast rehabilitation, no donor site morbidity, and early detection of tumor recurrence. Depending on the clinical setting, prosthetic rehabilitation may be more than just an alternative to plastic reconstructive surgery. Copyright Thieme Medical Publishers.

  11. A review of haptic simulator for oral and maxillofacial surgery based on virtual reality.

    PubMed

    Chen, Xiaojun; Hu, Junlei

    2018-06-01

    Traditional medical training in oral and maxillofacial surgery (OMFS) may be limited by its low efficiency and high price due to the shortage of cadaver resources. With the combination of visual rendering and feedback force, surgery simulators become increasingly popular in hospitals and medical schools as an alternative to the traditional training. Areas covered: The major goal of this review is to provide a comprehensive reference source of current and future developments of haptic OMFS simulators based on virtual reality (VR) for relevant researchers. Expert commentary: Visual rendering, haptic rendering, tissue deformation, and evaluation are key components of haptic surgery simulator based on VR. Compared with traditional medical training, virtual and tactical fusion of virtual environment in surgery simulator enables considerably vivid sensation, and the operators have more opportunities to practice surgical skills and receive objective evaluation as reference.

  12. Ear Tubes

    MedlinePlus

    ... 1/20th of an inch) that could allow water to enter the middle ear, research studies show no benefit in keeping the ears dry and current guidelines do not recommend routine water precautions. Therefore, you do not need to restrict ...

  13. Ear canal dynamic motion as a source of power for in-ear devices

    NASA Astrophysics Data System (ADS)

    Delnavaz, Aidin; Voix, Jérémie

    2013-02-01

    Ear canal deformation caused by temporomandibular joint (jaw joint) activity, also known as "ear canal dynamic motion," is introduced in this paper as a candidate source of power to possibly recharge hearing aid batteries. The geometrical deformation of the ear canal is quantified in 3D by laser scanning of different custom ear moulds. An experimental setup is proposed to measure the amount of power potentially available from this source. The results show that 9 mW of power is available from a 15 mm3 dynamic change in the ear canal volume. Finally, the dynamic motion and power capability of the ear canal are investigated in a group of 12 subjects.

  14. Tissue Expansion Using Hyaluronic Acid Filler for Single-Stage Ear Reconstruction: A Novel Concept for Difficult Areas.

    PubMed

    Inbal, Amir; Lemelman, Benjamin T; Millet, Eran; Greensmith, Andrew

    2017-10-16

    Auricular reconstruction is one of the most challenging procedures in plastic surgery. An adequate skin envelope is essential for cartilage framework coverage, yet few good options exist without additional surgery. We propose a novel method for minimally invasive tissue expansion, using hyaluronic acid (HA) filler to allow for single-stage ear reconstruction. To introduce the novel concept of HA filler for tissue expansion in ear reconstruction, and as an alternative to traditional expansion techniques. Macrolane is a large particle HA gel developed for large volume restoration. Expansion of the non-hair-bearing mastoid skin was performed in our clinic weekly or every other week. Final expansion was completed one week prior to reconstructive surgery. Tissue from one patient's expanded pocket was sent for histological analysis. Ten patients underwent single-stage auricular reconstruction with preoperative expansion. Injection sessions ranged from 7 to 13 (mean, 9.7). Mean injected volume per session was 2.03 mL per patient, for an average total of 19.8 mL (range, 14.5-30 mL). There were no major complications. One minor complication required removal of exposed wire from the antihelix in the office. Hematoxylin and eosin stain revealed similar histology to that seen with traditional expanders. This novel expansion technique using serial HA injections allowed for optimized skin coverage in single-stage ear reconstruction. The concept of tissue expansion using HA filler is a new frontier for research that may be applicable to other arenas of reconstruction. 4. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  15. Optical coherence tomography as a guide for cochlear implant surgery?

    NASA Astrophysics Data System (ADS)

    Just, T.; Lankenau, E.; Hüttmann, G.; Pau, H. W.

    2008-02-01

    To assess the potential use of optical coherence tomography (OCT) in cochlear implant surgery, OCT was applied in human temporal bones before cochleostomy. The question was whether OCT might provide information about the cochlear topography, especially about the site of the scala tympani. OCT was carried out on human temporal bone preparations, in which the cochleostomy was performed leaving the membranous labyrinth and the fluid-filled inner ear intact. A specially equipped operating microscope with integrated OCT prototype was used. Spectral-domain (SD)-OCT was used for all investigations. On all scans, OCT supplied information about inner ear structures, such as scala tympani, scala vestibuli while the membranous labyrinth was still intact. In the fresh temporal bone the scala media, basilar membrane and the Reissner's membrane were identified. This OCT study clearly documents the possibility to identify inner ear structures, especially the scala tympani without opening its enveloping membranes. These findings may have an impact on cochlear implant surgery, especially as an orientation guide to localize the scala tympani precisely before opening the fluid filled inner ear.

  16. External Otitis (Swimmer's Ear)

    MedlinePlus

    ... Debris removal, antibiotic ear drops, keeping water and cotton swabs out of the ear, and pain relievers ... Injuring the ear canal while cleaning it (using cotton swabs) or getting water or irritants, such as ...

  17. Model-based surgical planning and simulation of cranial base surgery.

    PubMed

    Abe, M; Tabuchi, K; Goto, M; Uchino, A

    1998-11-01

    Plastic skull models of seven individual patients were fabricated by stereolithography from three-dimensional data based on computed tomography bone images. Skull models were utilized for neurosurgical planning and simulation in the seven patients with cranial base lesions that were difficult to remove. Surgical approaches and areas of craniotomy were evaluated using the fabricated skull models. In preoperative simulations, hand-made models of the tumors, major vessels and nerves were placed in the skull models. Step-by-step simulation of surgical procedures was performed using actual surgical tools. The advantages of using skull models to plan and simulate cranial base surgery include a better understanding of anatomic relationships, preoperative evaluation of the proposed procedure, increased understanding by the patient and family, and improved educational experiences for residents and other medical staff. The disadvantages of using skull models include the time and cost of making the models. The skull models provide a more realistic tool that is easier to handle than computer-graphic images. Surgical simulation using models facilitates difficult cranial base surgery and may help reduce surgical complications.

  18. Ear Injuries (For Parents)

    MedlinePlus

    ... Inserting something into the ear. Things like a cotton swab, fingernail, or pencil can scratch the ear ... Never stick anything in their ears — not even cotton swabs or their fingers. Regular bathing should be ...

  19. Energy consumption during simulated minimal access surgery with and without using an armrest.

    PubMed

    Jafri, Mansoor; Brown, Stuart; Arnold, Graham; Abboud, Rami; Wang, Weijie

    2013-03-01

    Minimal access surgery (MAS) can be a lengthy procedure when compared to open surgery and therefore surgeon fatigue becomes an important issue and surgeons may expose themselves to chronic injuries and making errors. There have been few studies on this topic and they have used only questionnaires and electromyography rather than direct measurement of energy expenditure (EE). The aim of this study was to investigate whether the use of an armrest could reduce the EE of surgeons during MAS. Sixteen surgeons performed simulated MAS with and without using an armrest. They were required to perform the time-consuming task of using scissors to cut a rubber glove through its top layer in a triangular fashion with the help of a laparoscopic camera. Energy consumptions were measured using the Oxycon Mobile system during all the procedures. Error rate and duration time for simulated surgery were recorded. After performing the simulated surgery, subjects scored how comfortable they felt using the armrest. It was found that O(2) uptake (VO(2)) was 5 % less when surgeons used the armrest. The error rate when performing the procedure with the armrest was 35 % compared with 42.29 % without the armrest. Additionally, comfort levels with the armrest were higher than without the armrest. 75 % of surgeons indicated a preference for using the armrest during the simulated surgery. The armrest provides support for surgeons and cuts energy consumption during simulated MAS.

  20. Bassett healthcare rural surgery experience.

    PubMed

    Borgstrom, David C; Heneghan, Steven J

    2009-12-01

    The surgical training at Bassett is naturally broader than in many university settings, with a survey showing that nearly 70% of graduates who practice general surgery remain in a rurally designated area. Rural surgery experience falls into 3 categories: undergraduate, graduate, and postgraduate. The general surgery training program has no competing fellowships or subspecialty residencies; residents get significant experience with endoscopy; ear, nose, and throat; plastic and hand surgery; and obstetrics and gynecology. The rural setting lifestyle is valued by the students, residents, and fellows alike. It provides an ideal setting for recognizing the specific nuances of small-town American life, with a high-quality education and surgical experience.

  1. Chinchilla middle ear transmission matrix model and middle-ear flexibilitya)

    PubMed Central

    Ravicz, Michael E.; Rosowski, John J.

    2017-01-01

    The function of the middle ear (ME) in transforming ME acoustic inputs and outputs (sound pressures and volume velocities) can be described with an acoustic two-port transmission matrix. This description is independent of the load on the ME (cochlea or ear canal) and holds in either direction: forward (from ear canal to cochlea) or reverse (from cochlea to ear canal). A transmission matrix describing ME function in chinchilla, an animal commonly used in auditory research, is presented, computed from measurements of forward ME function: input admittance YTM, ME pressure gain GMEP, ME velocity transfer function HV, and cochlear input admittance YC, in the same set of ears [Ravicz and Rosowski (2012b). J. Acoust. Soc. Am. 132, 2437–2454; (2013a). J. Acoust. Soc. Am. 133, 2208–2223; (2013b). J. Acoust. Soc. Am. 134, 2852–2865]. Unlike previous estimates, these computations require no assumptions about the state of the inner ear, effectiveness of ME manipulations, or measurements of sound transmission in the reverse direction. These element values are generally consistent with physical constraints and the anatomical ME “transformer ratio.” Differences from a previous estimate in chinchilla [Songer and Rosowski (2007). J. Acoust. Soc. Am. 122, 932–942] may be due to a difference in ME flexibility between the two subject groups. PMID:28599566

  2. Chinchilla middle ear transmission matrix model and middle-ear flexibility.

    PubMed

    Ravicz, Michael E; Rosowski, John J

    2017-05-01

    The function of the middle ear (ME) in transforming ME acoustic inputs and outputs (sound pressures and volume velocities) can be described with an acoustic two-port transmission matrix. This description is independent of the load on the ME (cochlea or ear canal) and holds in either direction: forward (from ear canal to cochlea) or reverse (from cochlea to ear canal). A transmission matrix describing ME function in chinchilla, an animal commonly used in auditory research, is presented, computed from measurements of forward ME function: input admittance Y TM , ME pressure gain G MEP , ME velocity transfer function H V , and cochlear input admittance Y C , in the same set of ears [Ravicz and Rosowski (2012b). J. Acoust. Soc. Am. 132, 2437-2454; (2013a). J. Acoust. Soc. Am. 133, 2208-2223; (2013b). J. Acoust. Soc. Am. 134, 2852-2865]. Unlike previous estimates, these computations require no assumptions about the state of the inner ear, effectiveness of ME manipulations, or measurements of sound transmission in the reverse direction. These element values are generally consistent with physical constraints and the anatomical ME "transformer ratio." Differences from a previous estimate in chinchilla [Songer and Rosowski (2007). J. Acoust. Soc. Am. 122, 932-942] may be due to a difference in ME flexibility between the two subject groups.

  3. [Experimental investigations of CO2 laser application in middle ear ossicles].

    PubMed

    Dazert, S; Russ, D; Mlynski, R; Brors, D; Greiner, A; Aletsee, C; Helms, J

    2003-07-01

    During the last few years, several laser systems have been applied for procedures in middle ear surgery. In this study, we determined the technical parameters for the dissection of the middle ear ossicles with the CO(2) laser and analyzed the histological findings. The malleus necks of 16 human temporal bones were dissected under standardized conditions using a CO(2) laser with a power output between 35 and 55 kW/cm(2). The specimens were fixed and histological probes of 50- micro m thickness were prepared. The laser outputs led to crater diameters from 0.14 to 0.55 mm. As an analogy between laser energy and thermal tissue destruction, three zones of thermal damage were differentiated: a cinder zone, a carbonization zone, and a zone of dehydration. The metrical dimensions of these zones did not show any correlation to the applied laser energy. The data of this study show that commercially available CO(2) lasers are sufficient for a safe and effective partial resection of middle ear ossicles using a power output of 35 kW/cm(2).

  4. Taking Care of Your Ears

    MedlinePlus

    ... Audiologist Perforated Eardrum What's Hearing Loss? Can Loud Music Hurt My Ears? What Is an Ear Infection? Swimmer's Ear Your Ears What's Earwax? View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...

  5. Interactive computer simulations of knee-replacement surgery.

    PubMed

    Gunther, Stephen B; Soto, Gabriel E; Colman, William W

    2002-07-01

    Current surgical training programs in the United States are based on an apprenticeship model. This model is outdated because it does not provide conceptual scaffolding, promote collaborative learning, or offer constructive reinforcement. Our objective was to create a more useful approach by preparing students and residents for operative cases using interactive computer simulations of surgery. Total-knee-replacement surgery (TKR) is an ideal procedure to model on the computer because there is a systematic protocol for the procedure. Also, this protocol is difficult to learn by the apprenticeship model because of the multiple instruments that must be used in a specific order. We designed an interactive computer tutorial to teach medical students and residents how to perform knee-replacement surgery. We also aimed to reinforce the specific protocol of the operative procedure. Our final goal was to provide immediate, constructive feedback. We created a computer tutorial by generating three-dimensional wire-frame models of the surgical instruments. Next, we applied a surface to the wire-frame models using three-dimensional modeling. Finally, the three-dimensional models were animated to simulate the motions of an actual TKR. The tutorial is a step-by-step tutorial that teaches and tests the correct sequence of steps in a TKR. The student or resident must select the correct instruments in the correct order. The learner is encouraged to learn the stepwise surgical protocol through repetitive use of the computer simulation. Constructive feedback is acquired through a grading system, which rates the student's or resident's ability to perform the task in the correct order. The grading system also accounts for the time required to perform the simulated procedure. We evaluated the efficacy of this teaching technique by testing medical students who learned by the computer simulation and those who learned by reading the surgical protocol manual. Both groups then performed TKR on

  6. Middle Ear Infections (For Parents)

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español Middle Ear Infections KidsHealth / For Parents / Middle Ear Infections What's ... en español Infecciones del oído medio What Are Middle Ear Infections? Ear infections happen when viruses or bacteria ...

  7. Development of a finite element model of the middle ear.

    PubMed

    Williams, K R; Blayney, A W; Rice, H J

    1996-01-01

    A representative finite element model of the healthy ear is developed commencing with a description of the decoupled isotropic tympanic membrane. This model was shown to vibrate in a manner similar to that found both numerically (1, 2) and experimentally (8). The introduction of a fibre system into the membrane matrix significantly altered the modes of vibration. The first mode "remains as a piston like movement as for the isotropic membrane. However, higher modes show a simpler vibration pattern similar to the second mode but with a varying axis of movement and lower amplitudes. The introduction of a malleus and incus does not change the natural frequencies or mode shapes of the membrane for certain support conditions. When constraints are imposed along the ossicular chain by simulation of a cochlear impedance term then significantly altered modes can occur. More recently a revised model of the ear has been developed by the inclusion of the outer ear canal. This discretisation uses geometries extracted from a Nuclear Magnetic resonance scan of a healthy subject and a crude inner ear model using stiffness parameters ultimately fixed through a parameter tuning process. The subsequently tuned model showed behaviour consistent with previous findings and should provide a good basis for subsequent modelling of diseased ears and assessment of the performance of middle ear prostheses.

  8. A 3D virtual reality simulator for training of minimally invasive surgery.

    PubMed

    Mi, Shao-Hua; Hou, Zeng-Gunag; Yang, Fan; Xie, Xiao-Liang; Bian, Gui-Bin

    2014-01-01

    For the last decade, remarkable progress has been made in the field of cardiovascular disease treatment. However, these complex medical procedures require a combination of rich experience and technical skills. In this paper, a 3D virtual reality simulator for core skills training in minimally invasive surgery is presented. The system can generate realistic 3D vascular models segmented from patient datasets, including a beating heart, and provide a real-time computation of force and force feedback module for surgical simulation. Instruments, such as a catheter or guide wire, are represented by a multi-body mass-spring model. In addition, a realistic user interface with multiple windows and real-time 3D views are developed. Moreover, the simulator is also provided with a human-machine interaction module that gives doctors the sense of touch during the surgery training, enables them to control the motion of a virtual catheter/guide wire inside a complex vascular model. Experimental results show that the simulator is suitable for minimally invasive surgery training.

  9. Remodelling of the pinna in myxoid degeneration of the ear.

    PubMed

    Kean, J; Stewart, K J

    2010-07-01

    Idiopathic deformation of the pinna is not widely reported in the current literature. We present a series of cases in which patients have required surgery for spontaneous thickening and deformation of the auricular cartilage, and a description of a technique for surgical correction. Four cases of idiopathic deformation of the pinna are reported. Our preferred technique of scaphoid rim incision and anterior carving of the cartilage is described, with intra-operative photographs. Each patient reported spontaneous swelling of the upper poles of the ears beginning in the second or third decade of life. In 3 cases the deformity was bilateral, although in each of these cases one side was more severely affected than the other. Histology for these cases was reported as myxoid degeneration of the ear. All of the reported patients were pleased with the aesthetic outcome of their auricular remodelling. Currently, there are no typical patient demographics for idiopathic myxoid degeneration of the ear. We have achieved good aesthetic results by hand carving the anterior aspect of the deformed cartilage via scaphoid rim incisions. Copyright 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Activation of NLRP3 inflammasome in human middle ear cholesteatoma and chronic otitis media.

    PubMed

    Kariya, Shin; Okano, Mitsuhiro; Zhao, Pengfei; Kataoka, Yuko; Yoshinobu, Junko; Maeda, Yukihide; Ishihara, Hisashi; Higaki, Takaya; Nishizaki, Kazunori

    2016-01-01

    The nucleotide-binding oligomerization domain-like receptor protein 3 (NLRP3) inflammasome plays an important role in the pathogenesis of middle ear diseases. Modulation of inflammasome-mediated inflammation may be a novel therapeutic strategy for cholesteatoma and chronic otitis media. NLRP3 inflammasome is a critical molecule mediating interleukin (IL)-1β responses. However, the expression of NLRP3 in the pathogenesis of cholesteatoma and chronic otitis media has not been fully examined. This study sought to assess the expression of NLRP3, ASC (apoptosis-associated speck-like protein containing a caspase recruitment domain and a pyrin domain), and caspase-1 in middle ear tissues in patients with cholesteatoma or chronic otitis media. Middle ear tissue samples were obtained from patients with cholesteatoma or chronic otitis media. Control middle ear samples were collected during cochlear implant surgery of patients without middle ear inflammation. The expression of NLRP3, ASC, and caspase-1 were examined by reverse transcription polymerase chain reaction (RT-PCR) assay and immunohistochemical study. The levels of mRNA of NLRP3, ASC, and caspase-1 were significantly elevated in cholesteatoma and chronic otitis media as compared with that of normal controls. The proteins of NLRP3, ASC, and caspase-1 were observed in infiltrating inflammatory cells in cholesteatoma and chronic otitis media.

  11. Question mark ears, temporo-mandibular joint malformation and hypotonia: auriculo-condylar syndrome or a distinct entity?

    PubMed

    Priolo, M; Lerone, M; Rosaia, L; Calcagno, E P; Sadeghi, A K; Ghezzi, F; Ravazzolo, R; Silengo, M

    2000-10-01

    We report a boy with prominent, peculiarly malformed ears, abnormality of the ramus of the mandible and hypotonia. An isolated peculiar bilateral ear deformity named 'question mark ear' has been delineated in plastic reconstruction surgery reviews [Cosman et al., 1970 Plast Reconstr Surg 46:454-457; Cosman (1984) Plast Reconstr Surg 73:572-576; Takato et al. (1989) Ann Plast Surg 22:69-73; Brodovsky (1997) Plast Reconstr Surg 100:1254-1257; Park (1998) Plast Reconstr Surg 101:1620-1623; Al-Quattan (1998) Plast Reconstr Surg 102:439-441] and a similar deformity of the ear and changes in the temporo-mandibular joint and condyle has been described by Jampol et al. [(1998) Am J Med Genet 75:449-452] and by Guion-Almeida et al. [(1999) Am J Med Genet 86:130-133]. The present case may be the third description of this malformation complex with additional clinical features characterized by hypotonia and mild developmental delay, or possibly a new distinct entity.

  12. Cauliflower ear dissection.

    PubMed

    Fujiwara, Masao; Suzuki, Ayano; Nagata, Takeshi; Fukamizu, Hidekazu

    2011-11-01

    Cauliflower ear (CE) is caused by repeated direct trauma to the external ear. Surgical correction of an established CE is one of the most challenging problems in ear reconstruction. However, no reports have clarified the dissection of an established CE in detail. In this report, the dissection of a CE is described based on macroscopic, microscopic and imaging features. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Operating in an eczematous surgical field: don't be rash, delay surgery to avoid infective complications.

    PubMed

    Beckett, K S; Gault, D T

    2006-01-01

    Prominent ear correction is a common operation. Complication as a result of infection has been quoted at between 3% and 5% [Calder JC, Nasaan A. Morbidity of otoplasty: a review of 562 consecutive cases. Br J Plast Surg 1994;47:170-4 and Jeffery SLA. Complications following correction of prominent ears: an audit review of 122 cases. Br J Plast Surg 1999;52:588-90.]. We present two cases referred for ear reconstruction following catastrophic post-operative infection at the time of pinnaplasty, leaving each patient with significant helical rim deformities. Both patients displayed evidence of active post-auricular eczema at the time of their primary surgery. Dermatological research has highlighted the increased colonisation of Staphylococcus aureus in particular within areas of atopic eczema in comparison to normal skin. We advise delaying ear surgery in the presence of a rash in view of the potentially devastating complications that may result. This approach may be extended to all cutaneous surgery where treatment of the rash is advocated prior to embarking on an elective surgical procedure.

  14. Reconstruction of Punitive Ear Amputations in Uganda: A Unique Surgical Burden of Disease.

    PubMed

    Dusseldorp, Joseph; Hodges, Andrew; Patel, Anup; Marchac, Alexandre; Firmin, Françoise

    2015-06-01

    Over the course of 12 months, a plastic surgical team from Paris, France, undertook 2 intensive ear reconstruction missions with plastic surgeons from the CoRSU Rehabilitation Hospital in Uganda. A cohort of over 30 adult women was assessed having been subjected to ear amputations by members of the Lords Resistance Army in Northern Uganda in the 1990s. The patients were identified, mobilized, and transferred to Kampala for surgery by a charitable arm of the Watoto Church, known as Living Hope. The surgical team performed 15 ear reconstruction cases during the first 1-week mission and 16 ear reconstruction cases during the second 1-week mission. All cases were reconstructed successfully using the 2-stage autologous auricular reconstruction method advocated by the senior author (FF). Local skin was used to cover the costal cartilage framework in the first stage without need for temporo-parietal fascial flaps. Technical challenges included the older age of patients and ossified costal cartilage, high prevalence of HIV positivity, bilateral amputation, and difficulty of surgical follow-up. The main modifications to standard practice were routine pre-op testing of the costal cartilage, pre-op viral load and CD4 count screening in HIV-positive patients, simultaneous bilateral first-stage ear reconstruction, prolonged hospital stay, and implementation of routine surgical counting procedures.

  15. Estimation of outer-middle ear transmission using DPOAEs and fractional-order modeling of human middle ear

    NASA Astrophysics Data System (ADS)

    Naghibolhosseini, Maryam

    Our ability to hear depends primarily on sound waves traveling through the outer and middle ear toward the inner ear. Hence, the characteristics of the outer and middle ear affect sound transmission to/from the inner ear. The role of the middle and outer ear in sound transmission is particularly important for otoacoustic emissions (OAEs), which are sound signals generated in a healthy cochlea, and recorded by a sensitive microphone placed in the ear canal. OAEs are used to evaluate the health and function of the cochlea; however, they are also affected by outer and middle ear characteristics. To better assess cochlear health using OAEs, it is critical to quantify the impact of the outer and middle ear on sound transmission. The reported research introduces a noninvasive approach to estimate outer-middle ear transmission using distortion product otoacoustic emissions (DPOAEs). In addition, the role of the outer and middle ear on sound transmission was investigated by developing a physical/mathematical model, which employed fractional-order lumped elements to include the viscoelastic characteristics of biological tissues. Impedance estimations from wideband refectance measurements were used for parameter fitting of the model. The model was validated comparing its estimates of the outer-middle ear sound transmission with those given by DPOAEs. The outer-middle ear transmission by the model was defined as the sum of forward and reverse outer-middle ear transmissions. To estimate the reverse transmission by the model, the probe-microphone impedance was calculated through estimating the Thevenin-equivalent circuit of the probe-microphone. The Thevenin-equivalent circuit was calculated using measurements in a number of test cavities. Such modeling enhances our understanding of the roles of different parts of the outer and middle ear and how they work together to determine their function. In addition, the model would be potentially helpful in diagnosing pathologies of

  16. Prenatal evaluation of the middle ear and diagnosis of middle ear hypoplasia using MRI.

    PubMed

    Katorza, Eldad; Nahama-Allouche, Catherine; Castaigne, Vanina; Gonzales, Marie; Galliani, Eva; Marlin, Sandrine; Jouannic, Jean-Marie; Rosenblatt, Jonathan; le Pointe, Hubert Ducou; Garel, Catherine

    2011-05-01

    Analysis of the middle ear with fetal MRI has not been previously reported. To show the contribution of fetal MRI to middle ear imaging. The tympanic cavity was evaluated in 108 fetal cerebral MRI examinations (facial and/or cerebral malformation excluded) and in two cases, one of Treacher Collins syndrome (case 1) and the other of oculo-auriculo-vertebral (OUV) spectrum (case 2) with middle ear hypoplasia identified by MRI at 27 and 36 weeks' gestation, respectively. In all 108 fetuses (mean gestational age 32.5 weeks), the tympanic cavity and T2 hypointensity related to the ossicles were well visualised on both sides. Case 1 had micro/retrognathia and bilateral external ear deformity and case 2 had retrognathism with a left low-set and deformed ear. MRI made it possible to recognize the marked hypoplasia of the tympanic cavity, which was bilateral in case 1 and unilateral in case 2. Both syndromes are characterized by craniofacial abnormalities including middle ear hypoplasia, which cannot be diagnosed with US. The middle ear cavity can be visualized with fetal MRI. We emphasize the use of this imaging modality in the diagnosis of middle ear hypoplasia.

  17. Inner-ear decompression sickness: 'hubble-bubble' without brain trouble?

    PubMed

    Tremolizzo, Lucio; Malpieri, Massimo; Ferrarese, Carlo; Appollonio, Ildebrando

    2015-06-01

    Inner-ear decompression sickness (DCS) is an incompletely understood and increasingly recognized condition in compressed-air divers. Previous reports show a high association of inner-ear DCS with persistent foramen ovale (PFO), suggesting that a moderate-to-severe right-to-left shunt might represent a major predisposing factor, and more properly defining it as an event from arterial gas embolism (AGE). However, other conditions characterized by bubbles entering the arterial circulation, such as open-chamber cardiac surgery, do not produce inner-ear involvement, while sometimes damaging the brain extensively. Moreover, in other sites, such as the spinal cord, the prevailing mechanism for DCS is not AGE, but more likely local bubble formation with subsequent compression of venules and capillaries. Thus, AGE might be, more properly, a predisposing condition, neither sufficient, nor possibly even strictly necessary for inner-ear DCS. A 'two-hit hypothesis' has been proposed, implying a locally selective vulnerability of the inner ear to AGE. Modelled kinetics for gas removal are slower in the inner ear compared to the brain, leading to a supersaturated environment which allows bubbles to grow until they eventually obstruct the labyrinthine artery. Since this artery is relatively small, there is a low probability for a bubble to enter it; this might explain the disproportion between the high prevalence of PFO in the general population (25-30%) and the very low incidence of inner-ear DCS in compressed-air diving (approximately 0.005%). Furthermore, given that the labyrinthine artery usually originates either from the anterior inferior cerebellar artery, or directly from the basilar artery, shunting bubbles will more frequently swarm through the entire brain. In this case, however, the brain's much faster gas removal kinetics might allow for them to be reabsorbed without damaging brain tissue. In line with this scenario is the low probability (approx. 15%) of inner-ear

  18. Comparison of Psychophysical and Physical Measurements of Real Ear to Coupler Differences.

    PubMed

    Koning, Raphael; Wouters, Jan; Francart, Tom

    2015-01-01

    The purpose of the study is to compare real ear to coupler difference (RECD) curves based on physical and psychophysical measures. For the physically measured RECD, the RECD was measured with real ear and coupler measurements for the ear simulator and HA1- and HA2 2-cc couplers. The psychophysically measured RECDs were derived from audiogram measures. RECDs were measured in 19 normally hearing subjects. The coupler measurement was done with the probe microphone and the coupler microphone itself. Psychophysically measured RECDs were derived for all subjects by measuring the audiogram in sound field and with an ER-3A insert phone. Reference data were obtained for the three coupler types. It was possible to derive the RECD curve with psychophysical methods. There was no overall statistical difference between the physically and psychophysically measured RECD curves for the HA2 2-cc coupler and the ear simulator. The standard deviation was, however, much higher for the psychophysically derived RECD, indicating that physically measured RECDs are more precise than psychophysically derived RECDs. For the physical RECD measurements, the coupler microphone should be used for the coupler measurement. Physically measured RECDs were validated on group level by the reliable derivation of the RECD curve from audiogram measures.

  19. Bacterial strain changes during chronic otitis media surgery.

    PubMed

    Kim, G J; Yoo, S; Han, S; Bu, J; Hong, Y; Kim, D-K

    2017-09-01

    Cultures obtained from pre-operative middle-ear swabs from patients with chronic otitis media have traditionally been used to guide antibiotic selection. This study investigated changes in the bacterial strains of the middle ear during chronic otitis media surgery. Pre-operative bacterial cultures of otorrhoea, and peri-operative cultures of the granulation tissue in either the middle ear or mastoid cavity, were obtained. Post-operative cultures were selectively obtained when otorrhoea developed after surgery. Bacterial growth was observed in 45.5 per cent of pre-operative cultures, 13.5 per cent of peri-operative cultures and 4.5 per cent of post-operative cultures. Methicillin-resistant Staphylococcus aureus was identified as the most common bacteria in all pre-operative (32.4 per cent), peri-operative (52.4 per cent) and post-operative (71.4 per cent) tests, and the percentage of Methicillin-resistant S aureus increased from the pre- to the post-operative period. The bacterial culture results for post-operative otorrhoea showed low agreement with those for pre-operative or peri-operative culture, and strain re-identification was required.

  20. Ear-Canal Reflectance, Umbo Velocity and Tympanometry in Normal Hearing Adults

    PubMed Central

    Rosowski, John J; Nakajima, Hideko H.; Hamade, Mohamad A.; Mafoud, Lorice; Merchant, Gabrielle R.; Halpin, Christopher F.; Merchant, Saumil N.

    2011-01-01

    Objective This study compares measurements of ear-canal reflectance (ECR) to other objective measurements of middle-ear function including, audiometry, umbo velocity (VU), and tympanometry in a population of strictly defined normal hearing ears. Design Data were prospectively gathered from 58 ears of 29 normal hearing subjects, 16 female and 13 male, aged 22–64 years. Subjects met all of the following criteria to be considered as having normal hearing. (1) No history of significant middle-ear disease. (2) No history of otologic surgery. (3) Normal tympanic membrane (TM) on otoscopy. (4) Pure-tone audiometric thresholds of 20 dB HL or better for 0.25 – 8 kHz. (5) Air-bone gaps no greater than 15 dB at 0.25 kHz and 10 dB for 0.5 – 4 kHz. (6) Normal, type-A peaked tympanograms. (7) All subjects had two “normal” ears (as defined by these criteria). Measurements included pure-tone audiometry for 0.25 – 8 kHz, standard 226 Hz tympanometry, Ear canal reflectance(ECR) for 0.2 – 6 kHz at 60 dB SPL using the Mimosa Acoustics HearID system, and Umbo Velocity (VU ) for 0.3 – 6 kHz at 70–90 dB SPL using the HLV-1000 laser Doppler vibrometer (Polytec Inc). Results Mean power reflectance (|ECR|2) was near 1.0 at 0.2– 0.3 kHz, decreased to a broad minimum of 0.3 to 0.4 between 1 and 4 kHz, and then sharply increased to almost 0.8 by 6 kHz. The mean pressure reflectance phase angle (∠ECR) plotted on a linear frequency scale showed a group delay of approximately 0.1 ms for 0.2 – 6 kHz. Small significant differences were observed in |ECR|2 at the lowest frequencies between right and left ears, and between males and females at 4 kHz. |ECR|2 decreased with age, but reached significance only at 1 kHz. Our ECR measurements were generally similar to previous published reports. Highly significant negative correlations were found between |ECR|2 and VU for frequencies below 1 kHz. Significant correlations were also found between the tympanometrically determined peak

  1. Development and implementation of a clinical pathway approach to simulation-based training for foregut surgery.

    PubMed

    Miyasaka, Kiyoyuki W; Buchholz, Joseph; LaMarra, Denise; Karakousis, Giorgos C; Aggarwal, Rajesh

    2015-01-01

    Contemporary demands on resident education call for integration of simulation. We designed and implemented a simulation-based curriculum for Post Graduate Year 1 surgery residents to teach technical and nontechnical skills within a clinical pathway approach for a foregut surgery patient, from outpatient visit through surgery and postoperative follow-up. The 3-day curriculum for groups of 6 residents comprises a combination of standardized patient encounters, didactic sessions, and hands-on training. The curriculum is underpinned by a summative simulation "pathway" repeated on days 1 and 3. The "pathway" is a series of simulated preoperative, intraoperative, and postoperative encounters in following up a single patient through a disease process. The resident sees a standardized patient in the clinic presenting with distal gastric cancer and then enters an operating room to perform a gastrojejunostomy on a porcine tissue model. Finally, the resident engages in a simulated postoperative visit. All encounters are rated by faculty members and the residents themselves, using standardized assessment forms endorsed by the American Board of Surgery. A total of 18 first-year residents underwent this curriculum. Faculty ratings of overall operative performance significantly improved following the 3-day module. Ratings of preoperative and postoperative performance were not significantly changed in 3 days. Resident self-ratings significantly improved for all encounters assessed, as did reported confidence in meeting the defined learning objectives. Conventional surgical simulation training focuses on technical skills in isolation. Our novel "pathway" curriculum targets an important gap in training methodologies by placing both technical and nontechnical skills in their clinical context as part of managing a surgical patient. Results indicate consistent improvements in assessments of performance as well as confidence and support its continued usage to educate surgery residents

  2. The constricted ear.

    PubMed

    Paredes, Alfredo A; Williams, J Kerwin; Elsahy, Nabil I

    2002-04-01

    The constricted ear may be described best as a pursestring closure of the ear. The deformity may include lidding of the upper pole with downward folding, protrusion of the concha, decreased vertical height, and low ear position relative to the face. The goals of surgical correction should include obtaining symmetry and correcting the intra-auricular anatomy. The degree of intervention is based on the severity of the deformity and may range from simple repositioning, soft tissue rearrangement, or manipulation of the cartilage. Multiple surgical techniques are described.

  3. Virtual reality based surgery simulation for endoscopic gynaecology.

    PubMed

    Székely, G; Bajka, M; Brechbühler, C; Dual, J; Enzler, R; Haller, U; Hug, J; Hutter, R; Ironmonger, N; Kauer, M; Meier, V; Niederer, P; Rhomberg, A; Schmid, P; Schweitzer, G; Thaler, M; Vuskovic, V; Tröster, G

    1999-01-01

    Virtual reality (VR) based surgical simulator systems offer very elegant possibilities to both enrich and enhance traditional education in endoscopic surgery. However, while a wide range of VR simulator systems have been proposed and realized in the past few years, most of these systems are far from able to provide a reasonably realistic surgical environment. We explore the basic approaches to the current limits of realism and ultimately seek to extend these based on our description and analysis of the most important components of a VR-based endoscopic simulator. The feasibility of the proposed techniques is demonstrated on a first modular prototype system implementing the basic algorithms for VR-training in gynaecologic laparoscopy.

  4. Robotic Surgery Simulator: Elements to Build a Training Program.

    PubMed

    Tillou, Xavier; Collon, Sylvie; Martin-Francois, Sandrine; Doerfler, Arnaud

    2016-01-01

    Face, content, and construct validity of robotic surgery simulators were confirmed in the literature by several studies, but elements to build a training program are still lacking. The aim of our study was to validate a progressive training program and to assess according to prior surgical experience the amount of training needed with a robotic simulator to complete the program. Exercises using the Da Vinci Skill Simulator were chosen to ensure progressive learning. A new exercise could only be started if a minimal score of 80% was achieved in the prior one. The number of repetitions to achieve an exercise was not limited. We devised a "performance index" by calculating the ratio of the sum of scores for each exercise over the number of repetitions needed to complete the exercise with at least an 80% score. The study took place at the François Baclesse Cancer Center. Participants all work at the primary care university Hospital located next to the cancer center. A total of 32 surgeons participated in the study- 2 experienced surgeons, 8 junior and 8 senior residents in surgery, 6 registrars, and 6 attending surgeons. There was no difference between junior and senior residents, whereas the registrars had better results (p < 0.0001). The registrars performed less exercise repetitions compared to the junior or senior residents (p = 0.012). Attending surgeons performed significantly more repetitions than registrars (p = 0.024), but they performed fewer repetitions than junior or senior residents with no statistical difference (p = 0.09). The registrars had a performance index of 50, which is the best result among all novice groups. Attending surgeons were between senior and junior residents with an index at 33.85. Choice of basic exercises to manipulate different elements of the robotic surgery console in a specific and progressive order enables rapid progress. The level of prior experience in laparoscopic surgery affects outcomes. More advanced laparoscopic expertise

  5. Ear drainage culture

    MedlinePlus

    ... needed. Your health care provider will use a cotton swab to collect the sample from inside the ... Using a cotton swab to take a sample of drainage from the outer ear is not painful. However, ear pain may ...

  6. Development of a Drilling Simulator for Dental Implant Surgery.

    PubMed

    Kinoshita, Hideaki; Nagahata, Masahiro; Takano, Naoki; Takemoto, Shinji; Matsunaga, Satoru; Abe, Shinichi; Yoshinari, Masao; Kawada, Eiji

    2016-01-01

    The aim of this study was to develop and evaluate a dental implant surgery simulator that allows learners to experience the drilling forces necessary to perform an osteotomy in the posterior mandibular bone. The simulator contains a force-sensing device that receives input and counteracts this force, which is felt as resistance by the user. The device consists of an actuator, a load cell, and a control unit. A mandibular bone model was fabricated in which the predicted forces necessary to drill the cortical and trabecular bone were determined via micro CT image-based 3D finite element analysis. The simulator was evaluated by five dentists from the Department of Implantology at Tokyo Dental College. The ability of the evaluators to distinguish the drilling resistance through different regions of the mandibular bone was investigated. Of the five dentists, four sensed the change in resistance when the drill perforated the upper cortical bone. All five dentists were able to detect when the drill made contact with lingual cortical bone and when the lingual bone was perforated. This project successfully developed a dental implant surgery simulator that allows users to experience the forces necessary to drill through types of bone encountered during osteotomy. Furthermore, the researchers were able to build a device by which excessive drilling simulates a situation in which the lingual cortical bone is perforated--a situation that could lead to negative repercussions in a clinical setting. The simulator was found to be useful to train users to recognize the differences in resistance when drilling through the mandibular bone.

  7. Expression of keratinocyte growth factor (KGF) and its receptor in a middle-ear cavity problem.

    PubMed

    Yamamoto-Fukuda, Tomomi; Takahashi, Haruo; Koji, Takehiko

    2012-01-01

    To investigate the pathogenesis of one of the most troublesome conditions following ear surgery, a middle-ear cavity problem. Keratinocyte growth factor (KGF) and its receptor (KGFR), the ratio of proliferating epithelial cells using Ki-67, and the extent of infiltration of B cells and T cells were examined immunohistochemically in 10 ears with a cavity problem, 70 ears with cholesteatoma and 8 ears with normal skin at the retroauricular incision. KGF was positive in 40% of cavity problem specimens, 37.5% of normal skin specimens, and was positive in 88% of cholesteatoma specimens (cavity problem vs. cholesteatoma, p=0.0004). The positive rate of KGFR in the cavity problem group (33.3%) was between those in cholesteatoma (60%) and normal skin (0%). In contrast to the cholesteatoma specimens, a significantly smaller number of Ki-67 labeling index (LI) was detected in the cavity problem specimens. B cell LI was significantly higher but T cell LI was significantly lower in the cavity problem specimens than in the cholesteatoma group. Our present study indicated that the discordance of paracrine action between stromal KGF and epithelial KGFR with a large number of infiltrating B cells may play an important role in the pathogenesis of a cavity problem. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. Chinchilla middle-ear admittance and sound power: High-frequency estimates and effects of inner-ear modifications

    PubMed Central

    Ravicz, Michael E.; Rosowski, John J.

    2012-01-01

    The middle-ear input admittance relates sound power into the middle ear (ME) and sound pressure at the tympanic membrane (TM). ME input admittance was measured in the chinchilla ear canal as part of a larger study of sound power transmission through the ME into the inner ear. The middle ear was open, and the inner ear was intact or modified with small sensors inserted into the vestibule near the cochlear base. A simple model of the chinchilla ear canal, based on ear canal sound pressure measurements at two points along the canal and an assumption of plane-wave propagation, enables reliable estimates of YTM, the ME input admittance at the TM, from the admittance measured relatively far from the TM. YTM appears valid at frequencies as high as 17 kHz, a much higher frequency than previously reported. The real part of YTM decreases with frequency above 2 kHz. Effects of the inner-ear sensors (necessary for inner ear power computation) were small and generally limited to frequencies below 3 kHz. Computed power reflectance was ∼0.1 below 3.5 kHz, lower than with an intact ME below 2.5 kHz, and nearly 1 above 16 kHz. PMID:23039439

  9. Tumbling cartilage flap and free auricular composite tissue transplantation for correcting mild and moderate forms of constricted ear.

    PubMed

    Pan, Bo; Zhao, Yanyong; Zhuang, Hongxing; Lin, Lin; Liu, Lei; Jiang, Haiyue

    2010-01-01

    To report a new surgical approach that results in a natural size and contour of the external malformed constricted ear. A total of 62 consecutive patients with constricted ear underwent surgery between July 1, 2005, and December 31, 2007. Depending on the features and severity of the deformity, the methods of tumbling cartilage flap (CF), free auricular composite graft, or a combination of these 2 techniques were applied. A total of 45 patients were treated with the method of tumbling CF. Twelve were treated with an auricular composite graft from the contralateral ear, and in 5 patients a combination of the 2 methods was used. In all cases, there was an improvement in the size, shape, and symmetry of the ears, and most patients were satisfied with the outcome. Complications were rare, and there was no donor site deformity. The technique of tumbling CF and free auricular composite graft provides a simple and promising treatment for constricted ears. Furthermore, this technique is easy to apply with a predictable good outcome.

  10. Palpation Simulator of Beating Aorta for Cardiovascular Surgery Training

    NASA Astrophysics Data System (ADS)

    Yamamoto, Yasuhiro; Nakao, Megumi; Kuroda, Tomohiro; Oyama, Hiroshi; Komori, Masaru; Matsuda, Tetsuya; Sakaguchi, Genichi; Komeda, Masashi; Takahashi, Takashi

    In field of cardiovascular surgeries, palpation of aorta plays important roles in decision of surgical site.This paper develops palpation simulator of aorta based on a finite element based physical model.The proposed model calculates soft tissue deformation according to the affection of inner pressure and the operation of a surgeon.The proposed method is implemented on a prototype with dual PHANToM device.Experimental results confirmed our model achieves real time simulation of the surgical palpation.

  11. Systematic review on mentoring and simulation in laparoscopic colorectal surgery.

    PubMed

    Miskovic, Danilo; Wyles, Susannah M; Ni, Melody; Darzi, Ara W; Hanna, George B

    2010-12-01

    To identify and evaluate the influence of mentoring and simulated training in laparoscopic colorectal surgery (LCS) and define the key components for learning advanced technical skills. Laparoscopic colorectal surgery is a complex procedure, often being self-taught by senior surgeons. Educational issues such as inadequate training facilities or a shortfall of training fellowships may result in a slow uptake of LCS. The effectiveness of mentored and simulated training, however, remains unclear. We conducted a systematic search, using Ovid databases. Four study categories were identified: mentored versus nonmentored cases, training case selection, simulation, and assessment. We performed a meta-analysis and a mixed model regression on the difference of the main outcome measures (conversion rates, morbidity, and mortality) for mentored trainees and expert surgeons. We also compared conversion rates of mentored and nonmentored. Meta-analysis of risk factors for conversion was performed using published and unpublished data sets requested from various investigators. For studies on simulation, we compared scores of surveys on the perception of different training courses. Thirty-seven studies were included. Pooled weighted outcomes of mentored cases (n = 751) showed a lower conversion rate (13.3% vs 20.5%, P = 0.0332) compared with nonmentored cases (n = 695). Compared to expert case series (n = 5313), there was no difference in conversion (P = 0.2835), anastomotic leak (P = 0.8342), or mortality (P = 0.5680). A meta-analysis of training case selection data (n = 4444) revealed male sex (P < 0.0001), previous abdominal surgery (P = 0.0200), a BMI greater than 30 (P = 0.0050), an ASA of less than 2 (P < 0.0001), colorectal cancer (P < 0.0001) and intra-abdominal fistula (P < 0.0001), but not older than 64 years (P = 0.4800), to significantly increase conversion risk. Participants on cadaveric courses were highly satisfied with the teaching value yet trainees on an animal

  12. High correlation between performance on a virtual-reality simulator and real-life cataract surgery.

    PubMed

    Thomsen, Ann Sofia Skou; Smith, Phillip; Subhi, Yousif; Cour, Morten la; Tang, Lilian; Saleh, George M; Konge, Lars

    2017-05-01

    To investigate the correlation in performance of cataract surgery between a virtual-reality simulator and real-life surgery using two objective assessment tools with evidence of validity. Cataract surgeons with varying levels of experience were included in the study. All participants performed and videorecorded three standard cataract surgeries before completing a proficiency-based test on the EyeSi virtual-reality simulator. Standard cataract surgeries were defined as: (1) surgery performed under local anaesthesia, (2) patient age >60 years, and (3) visual acuity >1/60 preoperatively. A motion-tracking score was calculated by multiplying average path length and average number of movements from the three real-life surgical videos of full procedures. The EyeSi test consisted of five abstract and two procedural modules: intracapsular navigation, antitremor training, intracapsular antitremor training, forceps training, bimanual training, capsulorhexis and phaco divide and conquer. Eleven surgeons were enrolled. After a designated warm-up period, the proficiency-based test on the EyeSi simulator was strongly correlated to real-life performance measured by motion-tracking software of cataract surgical videos with a Pearson correlation coefficient of -0.70 (p = 0.017). Performance on the EyeSi simulator is significantly and highly correlated to real-life surgical performance. However, it is recommended that performance assessments are made using multiple data sources. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  13. Effect of the Yield Stress and r-value Distribution on the Earing Profile of Cup Drawing with Yld2000-2d Yield Function

    NASA Astrophysics Data System (ADS)

    Lou, Yanshan; Bae, Gihyun; Lee, Changsoo; Huh, Hoon

    2010-06-01

    This paper deals with the effect of the yield stress and r-value distribution on the earing in the cup drawing. The anisotropic yield function, Yld2000-2d yield function, is selected to describe the anisotropy of two metal sheets, 719B and AA5182-O. The tool dimension is referred from the Benchmark problem of NUMISHEET'2002. The Downhill Simplex method is applied to identify the anisotropic coefficients in Yld2000-2d yield function. Simulations of the drawing process are performed to investigate the earing profile of two materials. The earing profiles obtained from simulations are compared with the analytical model developed by Hosford and Caddell. Simulations are conducted with respect to the change of the yield stress and r-value distribution, respectively. The correlation between the anisotropy and the earing tendency is investigated based on simulation data. Finally, the earing mechanism is analyzed through the deformation process of the blank during the cup deep drawing. It can be concluded that ears locate at angular positions with lower yield stress and higher r-value while the valleys appear at the angular position with higher yield stress and lower r-value. The effect of the yield stress distribution is more important for the cup height distribution than that of the r-value distribution.

  14. Blended learning in surgery using the Inmedea Simulator.

    PubMed

    Funke, Katrin; Bonrath, Esther; Mardin, Wolf Arif; Becker, Jan Carl; Haier, Joerg; Senninger, Norbert; Vowinkel, Thorsten; Hoelzen, Jens Peter; Mees, Soeren Torge

    2013-02-01

    Recently, medical education in surgery has experienced several modifications. We have implemented a blended learning module in our teaching curriculum to evaluate its effectiveness, applicability, and acceptance in surgical education. In this prospective study, the traditional face-to-face learning of our teaching curriculum for fourth-year medical students (n = 116) was augmented by the Inmedea Simulator, a web-based E-learning system, with six virtual patient cases. Student results were documented by the system and learning success was determined by comparing patient cases with comparable diseases (second and sixth case). The acceptance among the students was evaluated with a questionnaire. After using the Inmedea Simulator, correct diagnoses were found significantly (P < 0.05) more often, while an incomplete diagnostic was seen significantly (P < 0.05) less often. Significant overall improvement (P < 0.05) was seen in sixth case (62.3 ± 5.6 %) vs. second case (53.9 ± 5.6 %). The questionnaire revealed that our students enjoyed the surgical seminar (score 2.1 ± 1.5) and preferred blended learning (score 2.5 ± 1.2) to conventional teaching. The blended learning approach using the Inmedea Simulator was highly appreciated by our medical students and resulted in a significant learning success. Blended learning appears to be a suitable tool to complement traditional teaching in surgery.

  15. Antifibrotic effect of dexamethasone/alginate-coated silicone sheet in the abraded middle ear mucosa.

    PubMed

    Jang, Chul Ho; Ahn, Seung Hyun; Kim, Geun Hyung

    2016-12-01

    Silicone sheet is a material which is commonly used in middle ear surgery to prevent the formation of adhesions between the tympanic membrane and the medial bony wall of the middle ear cavity. However, silicone sheet can induce a tight and hard fibrous capsule in the region of the stapes, and this is particularly common in cases of eustachian tube dysfunction. As a result of the fibrous encapsulation around the silicone sheet, postoperative aeration of the stapes can be interrupted causing poor hearing gain. In this study, we performed an in vitro and in vivo evaluation of the antifibrotic effects of a dexamethasone and alginate (Dx/alginate) coating on silicone sheet. The Dx/alginate-coated silicone sheets were fabricated using a plasma-treatment and coating method. The Dx/alginate-coated silicone sheets effectively limited in vitro fibroblast attachment and proliferation due to the controlled release of Dx, which can be modified by manipulation of the alginate coating. For the in-vivo evaluation, guinea pigs (albino, male, weighing 250g) were divided into two groups, with the control group (n=5) implanted with silicone sheet and the test group (n=5) receiving Dx/alginate-coated silicone sheet. Animals were sacrificed 3 weeks after implantation, and histological analysis was performed using hematoxylin and eosin (H&E) and immunohistochemical staining techniques. Dx/alginate-coated silicone sheets showed marked inhibition of fibrosis in both the in vitro and in vivo studies. Silicone sheet that incorporates a Dx/alginate coating can release Dx and inhibit fibrosis in the middle ear. This material could be utilized in middle ear surgery as a means of preserving proper aeration and hearing gain following ossiculoplasty. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Morphological effects of nanosecond- and femtosecond-pulsed laser ablation on human middle ear ossicles

    NASA Astrophysics Data System (ADS)

    Ilgner, Justus F.; Wehner, Martin; Lorenzen, Johann; Bovi, Manfred; Westhofen, Martin

    2004-07-01

    Introduction: Since the early 1980's, a considerable number of different laser systems have been introduced into reconstructive middle ear surgery. Depending on the ablation mode, however, pressure transients or thermal load to inner ear structures continue to be subject to discussion. Material and methods: We examined single spot ablations by a nanosecond-pulsed, frequency-tripled Nd:YAG-Laser (355 nm, beam diameter 10 μm, pulse rate 2 kHz, power 250 mW) on isolated human mallei. In a second set-up, a similar system (355 nm, beam diameter 20 μm, pulse rate 10 kHz, power 160-1500 mW) was coupled to a scanner to examine the morphology of bone surface ablation over an area of 1mm2. A third set-up employed a femtosecond-pulsed CrLiSAF-Oscillator (850 nm, pulse duration 100 fs, pulse energy 40μJ, beam diameter 36 μm, pulse rate 1 kHz) to compare these results with the former and with those obtained from a commercially available Er:YAG laser for ear surgery (Zeiss ORL E, 2940 nm, single pulse, energy 10-25 mJ). Results: In set-up 1 and 2, thermal effects in terms of marginal carbonization were visible in all single spot ablations of 1 s and longer. With ablations of 0.5 seconds, precise cutting margins with preservation of surrounding tissue could be observed. Cooling with saline solution resulted in no carbonization at 1500 mW and a scan speed of 500 mm/s. Set-up 3 equally showed no carbonization, although scanning times were longer and ablation less pronounced. Conclusion: Ultrashort pulsed laser systems could potentially aid further refinement of reconstructive microsurgery of the middle ear.

  17. Self-ear cleaning practices and the associated risk of ear injuries and ear-related symptoms in a group of university students.

    PubMed

    Khan, Nasim Banu; Thaver, Sivashnee; Govender, Samantha Marlene

    2017-12-31

    Self-ear cleaning is the insertion of objects into the ear canal to clean it, a widespread practice that has the potential to compromise its integrity as a natural, selfcleansing mechanism, and a risk factor for possible injuries. The practice is common among young adults and highest in university than any other graduates. This study aimed to determine the self-ear cleaning practices and associated risk of injury and related symptoms in undergraduate students at KwaZulu-Natal University. The descriptive survey utilized a self-administered questionnaire. Of the 206 participants that responded, 98% engaged in self-ear cleaning, with 75% indicating that it was beneficial. The commonest method (79.6%) being the use of cotton buds, with an associated injury rate of 2.4%. There was no statistically significant associations between those who used or did not use cotton buds and the symptoms experienced. The complications indicate that self-ear cleaning does pose a risk for injury, necessitating more community information and education.

  18. Economic Evaluation of Bariatric Surgery in Mexico Using Discrete Event Simulation.

    PubMed

    Zanela, Olivo Omar; Cabra, Hermilo Arturo; Meléndez, Guillermo; Anaya, Pablo; Rupprecht, Frederic

    2012-12-01

    Morbid obesity represents high costs to health institutions in controlling associated comorbidities. It has been shown that bariatric surgery resolves or improves comorbidities, thus reducing resource utilization. This analysis estimated the total costs of treating morbid obesity and related comorbidities through conventional treatment compared to bariatric surgery under the Mexican public health system perspective. An economic evaluation model was developed by using discrete event simulation. One hundred fifty patients were created in each arm, with considered comorbidities allocated randomly. Preoperative comorbidity prevalences and bariatric surgery's efficacy for resolving them were obtained from published literature. Comorbidity treatment costs were obtained from the 2007 Mexican Institute of Social Security diagnosis-related group list and publications from the National Institute of Public Health. Only 12 patients were operated each month on the surgical arm. Complications associated with comorbidities were not considered. The considered time frame for simulation was 10 years, with a 4.5% annual discount rate. Return on investment, or cost breakeven point, for bariatric surgery was obtained after 6.8 years. Total costs for the surgical group were 52% less than conventional treatment group costs after 10 years. Bariatric surgery reduced the cost of treating type 2 diabetes, hypertension, and hypercholesterolemia by 59%, 53%, and 65%, respectively. Return on investment for bariatric surgery in patients with type 2 diabetes as the only comorbidity was 4.4 years. Despite conservative assumptions, investment in bariatric surgery is recouped in 6.8 years, generating relevant potential savings in the treatment of morbidly obese patients. In high-risk subpopulations, return on investment time is shorter. Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  19. Theory of forward and reverse middle-ear transmission applied to otoacoustic emissions in infant and adult ears

    PubMed Central

    Keefe, Douglas H.; Abdala, Carolina

    2008-01-01

    The purpose of this study is to understand why otoacoustic emission (OAE) levels are higher in normal-hearing human infants relative to adults. In a previous study, distortion product (DP) OAE input/output (I/O) functions were shown to differ at f2=6 kHz in adults compared to infants through 6 months of age. These DPOAE I/O functions were used to noninvasively assess immaturities in forward/reverse transmission through the ear canal and middle ear [Abdala, C., and Keefe, D. H., (2006). J. Acoust Soc. Am. 120, 3832–3842]. In the present study, ear-canal reflectance and DPOAEs measured in the same ears were analyzed using a scattering-matrix model of forward and reverse transmission in the ear canal, middle ear, and cochlea. Reflectance measurements were sensitive to frequency-dependent effects of ear-canal and middle-ear transmission that differed across OAE type and subject age. Results indicated that DPOAE levels were larger in infants mainly because the reverse middle-ear transmittance level varied with ear-canal area, which differed by more than a factor of 7 between term infants and adults. The forward middle-ear transmittance level was −16 dB less in infants, so that the conductive efficiency was poorer in infants than adults. PMID:17348521

  20. Red ear syndrome.

    PubMed

    Purdy, R Allan; Dodick, David W

    2007-08-01

    The red ear syndrome is a rare syndrome originally described by Lance in 1994. It involves pain in and around the ear and associated autonomic phenomena, the most significant of which is cutaneous erythema of the ear ipsilateral to the pain and obvious to the patient and examiner during the attack. It may well represent an auriculo-autonomic cephalgia and/or be part of the group of disorders recognized as trigeminal autonomic cephalalgias. As a syndrome, it still lacks specificity in regard to etiology, mechanisms, and treatment but is important to recognize clinically because of its associations.

  1. Could ionizing radiation forestall cauliflower ear?

    PubMed

    Hwang, K; Kim, C W; Lee, S I; Park, I S; Kim, W C; Loh, J J

    2001-02-01

    Repeated trauma to the ear very often results in "cauliflower ear." Many methods have been suggested to prevent an injured ear from demonstrating a cauliflowerlike deformity. The principles of treatment are evacuation of the hematoma, control of the reaccumulation of fluid, and maintenance of the cartilage contour. The authors studied the effect of ionizing radiation on deformed rabbit ears induced by repeated trauma. Twenty ears (10 rabbits) were used in the experiment. The animals were divided into four groups (control, preradiation, low dose, and high dose). Hematoma was produced by pounding the lateral side of the auricle 10 times with a 50-g weight at a height of 15 cm. The thickness of the injured and uninjured sites was measured, and histological analysis was performed for each group. The thickness of the ears of the irradiated groups was significantly less than the control group. The authors think that radiation treatment of repeatedly injured ears could prevent ear deformity, and could possibly be an adjunctive form of management of cauliflower ear in addition to hematoma evacuation and compression therapy.

  2. High-resolution microendoscope images of middle ear cholesteatoma and surrounding tissue: evaluation of interobserver concordance.

    PubMed

    Bradley, James; Jiang, Nancy; Levy, Lauren; Richards-Kortum, Rebecca; Sikora, Andrew; Smouha, Eric

    2014-04-01

    Investigate how accurately otolaryngologists could differentiate between images obtained with high-resolution microendoscopy (HRME) of ex vivo cholesteatoma specimens and surrounding middle ear epithelium. HRME images of surgically resected cholesteatoma and middle ear epithelium were obtained and otolaryngologists classified these images. Tertiary medical center. Resected cholesteatoma and middle ear epithelium were stained with a contrast agent, proflavine, and HRME images were captured. Specimens were sent for standard histopathology and compared with HRME images. Quality-controlled images were used to assemble a training set. After viewing training images, otolaryngologists without prior cholesteatoma HRME experience reviewed and classified test images. Ten cholesteatoma and 9 middle ear specimens were collected, of which 17 representative cholesteatoma and 19 middle ear epithelium images were extracted for a testing set. Qualitative analysis for concordance between HRME images and histological images yielded a strong correlation between modalities. The mean accuracy of all reviewers in correctly identifying images was 95% (95% confidence interval [CI], 92%-98%). The sensitivity to correctly detect cholesteatoma images was 98% (95% CI, 93%-100%), and the specificity was 92% (95% CI, 87%-97%). The Fleiss kappa interrater reliability score was 0.83, (95% CI, 0.77-0.89). Medical professionals can quickly be trained to accurately distinguish between HRME images of cholesteatoma and normal middle ear epithelium, both of which have distinct imaging characteristics. Real-time HRME optical imaging can potentially improve the results of otologic surgery by allowing for extirpation of cholesteatomas while eliminating residual disease.

  3. A systematic review of validated sinus surgery simulators.

    PubMed

    Stew, B; Kao, S S-T; Dharmawardana, N; Ooi, E H

    2018-06-01

    Simulation provides a safe and effective opportunity to develop surgical skills. A variety of endoscopic sinus surgery (ESS) simulators has been described in the literature. Validation of these simulators allows for effective utilisation in training. To conduct a systematic review of the published literature to analyse the evidence for validated ESS simulation. Pubmed, Embase, Cochrane and Cinahl were searched from inception of the databases to 11 January 2017. Twelve thousand five hundred and sixteen articles were retrieved of which 10 112 were screened following the removal of duplicates. Thirty-eight full-text articles were reviewed after meeting search criteria. Evidence of face, content, construct, discriminant and predictive validity was extracted. Twenty articles were included in the analysis describing 12 ESS simulators. Eleven of these simulators had undergone validation: 3 virtual reality, 7 physical bench models and 1 cadaveric simulator. Seven of the simulators were shown to have face validity, 7 had construct validity and 1 had predictive validity. None of the simulators demonstrated discriminate validity. This systematic review demonstrates that a number of ESS simulators have been comprehensively validated. Many of the validation processes, however, lack standardisation in outcome reporting, thus limiting a meta-analysis comparison between simulators. © 2017 John Wiley & Sons Ltd.

  4. Ear tube insertion

    MedlinePlus

    ... eardrum may cause some hearing loss. But most children do not have long-term damage to their hearing or speech, even when the ... not go away with treatment, or if a child has many ear infections ... or that damages nearby nerves Injury to the ear after sudden ...

  5. Factors contributing to hearing impairment in patients with cleft lip/palate in Malaysia: A prospective study of 346 ears.

    PubMed

    Cheong, Jack Pein; Soo, Siew Shuin; Manuel, Anura Michelle

    2016-09-01

    To determine the factors contributing towards hearing impairment in patients with cleft lip/palate. A prospective analysis was conducted on 173 patients (346 ears) with cleft lip and palate (CL/P) who presented to the combined cleft clinic at University Malaya Medical Centre (UMMC) over 12 months. The patients' hearing status was determined using otoacoustic emission (OAE), pure tone audiometry (PTA) and auditory brainstem response (ABR). These results were analysed against several parameters, which included age, gender, race, types of cleft pathology, impact and timing of repair surgery. The patients' age ranged from 1-26 years old. They comprised 30% with unilateral cleft lip and palate (UCLP), 28% with bilateral cleft lip and palate (BCLP), 28% with isolated cleft palate (ICP) and 14% with isolated cleft lip (ICL). Majority of the patients (68.2%) had normal otoscopic findings. Out of the 346 ears, 241 ears (70%) ears had passed the hearing tests. There was no significant relationship between patients' gender and ethnicity with their hearing status. The types of cleft pathology significantly influenced the outcome of PTA and ABR screening results (p < 0.001). There was no significant difference between the repaired and unrepaired cleft groups and the outcome of hearing tests. However, hearing improvement occurred when palatal repair was performed at the age of <1year old (OR = 2.37, CI 1.2 = 4.6, p = 0.01). Majority of the cleft patients had normal hearing (70%). Hearing threshold varied significantly between the different types of cleft pathology. Surgery conferred no significant impact on the hearing outcome unless surgery was performed at the age of <1 year old. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. [The history of pediatric plastic surgery].

    PubMed

    Glicenstein, J

    2016-10-01

    The history of pediatric plastic surgery is linked to that of paediatrics. Until the early 19th century, there was no children's hospital. Only some operations were performed before the discovery of anesthesia, aseptic and antisepsis: cleft lip repair, amputation for polydactyly. Many operations were described in the 19th century for cleft lip and palate repair, hypospadias, syndactylies. The first operation for protruding ears was performed in 1881. Pediatric plastic surgery is diversified in the 2nd half of the 20th century: cleft lip and palate, burns, craniofacial surgery, hand surgery become separate parts of the speciality. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. A Mathematical Model for the Middle Ear Ventilation

    NASA Astrophysics Data System (ADS)

    Molnárka, G.; Miletics, E. M.; Fücsek, M.

    2008-09-01

    The otitis media is one of the mostly existing illness for the children, therefore investigation of the human middle ear ventilation is an actual problem. In earlier investigations both experimental and theoretical approach one can find in ([l]-[3]). Here we give a new mathematical and computer model to simulate this ventilation process. This model able to describe the diffusion and flow processes simultaneously, therefore it gives more precise results than earlier models did. The article contains the mathematical model and some results of the simulation.

  8. Global ENT Outreach: Taking Ear, Nose, and Throat Treatment and Surgery Techniques to Ethiopia

    ERIC Educational Resources Information Center

    Wagner, Richard

    2007-01-01

    The author, as an otolaryngologist and the Director of Global ENT (Ear, Nose and Throat) Outreach, traveled to Ethiopia to help 11 children who could not breathe because of respiratory papillomas blocking their airways and who had been hospitalized for years. The disease, called juvenile respiratory papillomatosis, is what affected these 11…

  9. The quartile benefit plot: a middle ear surgery benefit assessment scheme.

    PubMed

    Schmerber, Sébastien; Karkas, Alexandre; Righini, Christian A; Chahine, Karim A

    2008-05-01

    The purpose of this study is to present a new method for the assessment of hearing improvement following stapes surgery, taking into account additional, previously omitted evaluation criteria. Retrospective. A quartile plot, based on the currently used Glasgow benefit plot, is structured to include two additional criteria of hearing assessment, namely the absence of postoperative sensorineural hearing loss and the closure of the air-bone gap to <10 dB. Pre- and postoperative hearing results of 132 patients diagnosed with bilateral otosclerosis and treated with bilateral stapes surgery were plotted on both the classical Glasgow benefit plot and the new quartile benefit plot. The difference in success assessment due to stricter assessment criteria is demonstrated. Functional success rate following bilateral stapes surgery as plotted on the traditional Glasgow benefit plot was 51.5%. Success rate for bilateral stapes surgery assessed on the new quartile plot with the addition of the two new criteria was 38.64%. The difference in success rates was found to be statistically significant. The basis of benefit assessment in stapes surgery solely on the mean deficit in air conduction results in overestimation of success rate. This study demonstrates that results that appear satisfactory when judged by the Glasgow benefit plot are of modest success when assessed by the new quartile plot. The quartile benefit plot presented in this paper provides a strict measure of presentation and evaluation of stapes surgery results.

  10. Developing a National, Simulation-Based, Surgical Skills Bootcamp in General Thoracic Surgery.

    PubMed

    Schieman, Colin; Ujiie, Hideki; Donahoe, Laura; Hanna, Waël; Malthaner, Richard; Turner, Simon; Czarnecka, Kasia; Yasufuku, Kazuhiro

    2017-12-12

    The use surgical simulation across all subspecialties has gained widespread adoption in the last decade. A number of factors, including the small number of trainees, identified gaps in surgical skill training from cross-sectional surveys, increased national collaboration, and support from the national specialty committee identified a need to construct a surgical skills "bootcamp" in thoracic surgery in Canada. The goals of the surgical skills bootcamp, as identified by the residency training program directors and the national specialty committee were to create a national, centralized, simulation-based skills workshop that focused on key foundational procedures within thoracic surgery, particularly those identified as areas of weakness by former residents; to smooth the transition to intraoperative teaching; to provide exposure to important but not necessarily universally available procedures such as advanced endoscopy; to teach non-medical expert competencies, and lastly to provide a venue for networking for residents across the country. The curriculum committee has constructed a 3.5 day curriculum, with a focus on hands-on skills simulation, as well as lectures, on a breadth of topics including benign esophageal disorders, lung cancer staging, minimally invasive lung surgery, crisis management and advanced bronchoscopy and endoscopy. All residents across the country attend as well as faculty from a variety of institutions. The course is hosted centrally at the University of Toronto, Ontario over 3.5 days. A combination of auditorium and both animal and human operating room facilities are utilized. A needs-assessment based on a formal meeting of the program directors, as well feedback from surveys identified the target areas for curriculum development. A committee of interested faculty developed the content as well as the local construct and logistics required. Iterative feedback has evolved the duration and content over the initial 3 years. Through formal resident

  11. Validation of virtual-reality-based simulations for endoscopic sinus surgery.

    PubMed

    Dharmawardana, N; Ruthenbeck, G; Woods, C; Elmiyeh, B; Diment, L; Ooi, E H; Reynolds, K; Carney, A S

    2015-12-01

    Virtual reality (VR) simulators provide an alternative to real patients for practicing surgical skills but require validation to ensure accuracy. Here, we validate the use of a virtual reality sinus surgery simulator with haptic feedback for training in Otorhinolaryngology - Head & Neck Surgery (OHNS). Participants were recruited from final-year medical students, interns, resident medical officers (RMOs), OHNS registrars and consultants. All participants completed an online questionnaire after performing four separate simulation tasks. These were then used to assess face, content and construct validity. anova with post hoc correlation was used for statistical analysis. The following groups were compared: (i) medical students/interns, (ii) RMOs, (iii) registrars and (iv) consultants. Face validity results had a statistically significant (P < 0.05) difference between the consultant group and others, while there was no significant difference between medical student/intern and RMOs. Variability within groups was not significant. Content validity results based on consultant scoring and comments indicated that the simulations need further development in several areas to be effective for registrar-level teaching. However, students, interns and RMOs indicated that the simulations provide a useful tool for learning OHNS-related anatomy and as an introduction to ENT-specific procedures. The VR simulations have been validated for teaching sinus anatomy and nasendoscopy to medical students, interns and RMOs. However, they require further development before they can be regarded as a valid tool for more advanced surgical training. © 2015 John Wiley & Sons Ltd.

  12. Anomalies of the middle and inner ear.

    PubMed

    Rodriguez, Kimsey; Shah, Rahul K; Kenna, Margaret

    2007-02-01

    The development of the middle and inner ear highlights the intricacy of embryology. As early as 3 weeks after fertilization, the inner ear begins taking form. This process, along with development of the middle ear, continues throughout gestation. At birth, the middle ear, inner ear, and associated structures are almost adult size. An understanding of the embryologic development of the ear serves as a foundation for evaluating and managing congenital malformations of these structures. The focus of this article is the normal, abnormal, and arrested development of the middle and inner ear, with a clinical emphasis on malformed middle and inner ear structures and a discussion of associated syndromes.

  13. [Analyses of the factors relevant to revision tympanomastoid surgery].

    PubMed

    Li, Li; Fan, Zhaomin; Han, Yuechen; Xu, Lei; Chen, Dong; Wang, Haibo

    2016-05-01

    To analyze factors relevant to revisional tympanomastoid surgery for chronic otitis media(COM). The clinical data of 159 patients (159 ears), who exhibited either wet ear or relapsed after the initial operation, and were subjected to revisional tympanomastoid surgery, were retrospectively analyzed in this study. Of those 159 consecutive patients, 85 were males and 74 were females, aged 11-64 years, with a median age of 36 years old. The situations in terms of intra-operative findings, surgical procedures, change dressing post-operation, dry ear time, and the improvement of aural ability during the second operation, were recorded and analyzed. The second surgery found that, of those 159 patients underwent the re-operation, 67 presented with cholesteatoma and 92 had no cholesteatoma. In addition, the inadequate skeletonization and insufficient opening for mastoid cavity accounted for 70.4% (112/159) of all previous operations, the external auditory canal stenosis for 98.7% (157/159), the high facial ridge leading to insufficient drainage for 61.0% (97/159), the lesion in tympanic ostium of Eustachian tube for 34.6% (55/159), the insufficient drainage due to inappropriate post-operating dressing for 5.0% (8/159), the postauricular incision for 30.8% (49/159), and the endaural incision for 69.2% (110/159). As for the re-operation of the canal wall down mastoidectomy, tympanoplasty plus plastic repairing of cavity of concha were performed in 94 cases, the modified Bondy plus plastic repairing of cavity of concha in four cases, the radical mastoidectomy plus plastic repairing of cavity of concha in 59 cases, and the simple cleaning for mastoid cavity in two cases. Since one to two weeks after the revisional operations, the post-operating dressing was performed with aid of microscopy once a week on average. The average dry ear time ranged from 2 to 6 weeks (median=3 weeks). During a period of 6-93 months for the follow-up, all patients presented with dry ears. The

  14. Structure and function of the mammalian middle ear. I: Large middle ears in small desert mammals.

    PubMed

    Mason, Matthew J

    2016-02-01

    Many species of small desert mammals are known to have expanded auditory bullae. The ears of gerbils and heteromyids have been well described, but much less is known about the middle ear anatomy of other desert mammals. In this study, the middle ears of three gerbils (Meriones, Desmodillus and Gerbillurus), two jerboas (Jaculus) and two sengis (elephant-shrews: Macroscelides and Elephantulus) were examined and compared, using micro-computed tomography and light microscopy. Middle ear cavity expansion has occurred in members of all three groups, apparently in association with an essentially 'freely mobile' ossicular morphology and the development of bony tubes for the middle ear arteries. Cavity expansion can occur in different ways, resulting in different subcavity patterns even between different species of gerbils. Having enlarged middle ear cavities aids low-frequency audition, and several adaptive advantages of low-frequency hearing to small desert mammals have been proposed. However, while Macroscelides was found here to have middle ear cavities so large that together they exceed brain volume, the bullae of Elephantulus are considerably smaller. Why middle ear cavities are enlarged in some desert species but not others remains unclear, but it may relate to microhabitat. © 2015 Anatomical Society.

  15. State of the evidence on simulation-based training for laparoscopic surgery: a systematic review.

    PubMed

    Zendejas, Benjamin; Brydges, Ryan; Hamstra, Stanley J; Cook, David A

    2013-04-01

    Summarize the outcomes and best practices of simulation training for laparoscopic surgery. Simulation-based training for laparoscopic surgery has become a mainstay of surgical training. Much new evidence has accrued since previous reviews were published. We systematically searched the literature through May 2011 for studies evaluating simulation, in comparison with no intervention or an alternate training activity, for training health professionals in laparoscopic surgery. Outcomes were classified as satisfaction, skills (in a test setting) of time (to perform the task), process (eg, performance rating), product (eg, knot strength), and behaviors when caring for patients. We used random effects to pool effect sizes. From 10,903 articles screened, we identified 219 eligible studies enrolling 7138 trainees, including 91 (42%) randomized trials. For comparisons with no intervention (n = 151 studies), pooled effect size (ES) favored simulation for outcomes of knowledge (1.18; N = 9 studies), skills time (1.13; N = 89), skills process (1.23; N = 114), skills product (1.09; N = 7), behavior time (1.15; N = 7), behavior process (1.22; N = 15), and patient effects (1.28; N = 1), all P < 0.05. When compared with nonsimulation instruction (n = 3 studies), results significantly favored simulation for outcomes of skills time (ES, 0.75) and skills process (ES, 0.54). Comparisons between different simulation interventions (n = 79 studies) clarified best practices. For example, in comparison with virtual reality, box trainers have similar effects for process skills outcomes and seem to be superior for outcomes of satisfaction and skills time. Simulation-based laparoscopic surgery training of health professionals has large benefits when compared with no intervention and is moderately more effective than nonsimulation instruction.

  16. Surgical correction of cauliflower ear.

    PubMed

    Yotsuyanagi, T; Yamashita, K; Urushidate, S; Yokoi, K; Sawada, Y; Miyazaki, S

    2002-07-01

    We have classified the cauliflower ear into different types according to the zone and the degree of deformity. One major group is deformity without change in the outline of the ear, and this is divided into four subgroups according to the zone. All of these subgroups can be treated by shaving the deformed cartilage through suitable incision lines. For deformities accompanied by a skin deficit, a postauricular skin flap should be used. The other major group is deformity accompanied by a change in the outline of the ear, which is divided into two subgroups. If the ear is rigid, a conchal cartilage graft is used. If the structural integrity of the ear is poor, costal cartilage is used to provide rigidity.

  17. Educational program in crisis management for cardiac surgery teams including high realism simulation.

    PubMed

    Stevens, Louis-Mathieu; Cooper, Jeffrey B; Raemer, Daniel B; Schneider, Robert C; Frankel, Allan S; Berry, William R; Agnihotri, Arvind K

    2012-07-01

    Cardiac surgery demands effective teamwork for safe, high-quality care. The objective of this pilot study was to develop a comprehensive program to sharpen performance of experienced cardiac surgical teams in acute crisis management. We developed and implemented an educational program for cardiac surgery based on high realism acute crisis simulation scenarios and interactive whole-unit workshop. The impact of these interventions was assessed with postintervention questionnaires, preintervention and 6-month postintervention surveys, and structured interviews. The realism of the acute crisis simulation scenarios gradually improved; most participants rated both the simulation and whole-unit workshop as very good or excellent. Repeat simulation training was recommended every 6 to 12 months by 82% of the participants. Participants of the interactive workshop identified 2 areas of highest priority: encouraging speaking up about critical information and interprofessional information sharing. They also stressed the importance of briefings, early communication of surgical plan, knowing members of the team, and continued simulation for practice. The pre/post survey response rates were 70% (55/79) and 66% (52/79), respectively. The concept of working as a team improved between surveys (P = .028), with a trend for improvement in gaining common understanding of the plan before a procedure (P = .075) and appropriate resolution of disagreements (P = .092). Interviewees reported that the training had a positive effect on their personal behaviors and patient care, including speaking up more readily and communicating more clearly. Comprehensive team training using simulation and a whole-unit interactive workshop can be successfully deployed for experienced cardiac surgery teams with demonstrable benefits in participant's perception of team performance. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  18. Gait Analysis From a Single Ear-Worn Sensor: Reliability and Clinical Evaluation for Orthopaedic Patients.

    PubMed

    Jarchi, Delaram; Lo, Benny; Wong, Charence; Ieong, Edmund; Nathwani, Dinesh; Yang, Guang-Zhong

    2016-08-01

    Objective assessment of detailed gait patterns after orthopaedic surgery is important for post-surgical follow-up and rehabilitation. The purpose of this paper is to assess the use of a single ear-worn sensor for clinical gait analysis. A reliability measure is devised for indicating the confidence level of the estimated gait events, allowing it to be used in free-walking environments and for facilitating clinical assessment of orthopaedic patients after surgery. Patient groups prior to or following anterior cruciate ligament (ACL) reconstruction and knee replacement were recruited to assess the proposed method. The ability of the sensor for detailed longitudinal analysis is demonstrated with a group of patients after lower limb reconstruction by considering parameters such as temporal and force-related gait asymmetry derived from gait events. The results suggest that the ear-worn sensor can be used for objective gait assessments of orthopaedic patients without the requirement and expense of an elaborate laboratory setup for gait analysis. It significantly simplifies the monitoring protocol and opens the possibilities for home-based remote patient assessment.

  19. Simulation-Based Training - Evaluation of the Course Concept "Laparoscopic Surgery Curriculum" by the Participants.

    PubMed

    Köckerling, Ferdinand; Pass, Michael; Brunner, Petra; Hafermalz, Matthias; Grund, Stefan; Sauer, Joerg; Lange, Volker; Schröder, Wolfgang

    2016-01-01

    The learning curve in minimally invasive surgery is much longer than in open surgery. This is thought to be due to the higher demands made on the surgeon's skills. Therefore, the question raised at the outset of training in laparoscopic surgery is how such skills can be acquired by undergoing training outside the bounds of clinical activities to try to shorten the learning curve. Simulation-based training courses are one such model. In 2011, the surgery societies of Germany adopted the "laparoscopic surgery curriculum" as a recommendation for the learning content of systematic training courses for laparoscopic surgery. The curricular structure provides for four 2-day training courses. These courses offer an interrelated content, with each course focusing additionally on specific topics of laparoscopic surgery based on live operations, lectures, and exercises carried out on bio simulators. Between 1st January, 2012 and 31st March, 2016, a total of 36 training courses were conducted at the Vivantes Endoscopic Training Center in accordance with the "laparoscopic surgery curriculum." The training courses were attended by a total of 741 young surgeons and were evaluated as good to very good during continuous evaluation by the participants. Training courses based on the "laparoscopic surgery curriculum" for acquiring skills in laparoscopy are taken up and positively evaluated by young surgeons.

  20. Virtual reality simulators and training in laparoscopic surgery.

    PubMed

    Yiannakopoulou, Eugenia; Nikiteas, Nikolaos; Perrea, Despina; Tsigris, Christos

    2015-01-01

    Virtual reality simulators provide basic skills training without supervision in a controlled environment, free of pressure of operating on patients. Skills obtained through virtual reality simulation training can be transferred on the operating room. However, relative evidence is limited with data available only for basic surgical skills and for laparoscopic cholecystectomy. No data exist on the effect of virtual reality simulation on performance on advanced surgical procedures. Evidence suggests that performance on virtual reality simulators reliably distinguishes experienced from novice surgeons Limited available data suggest that independent approach on virtual reality simulation training is not different from proctored approach. The effect of virtual reality simulators training on acquisition of basic surgical skills does not seem to be different from the effect the physical simulators. Limited data exist on the effect of virtual reality simulation training on the acquisition of visual spatial perception and stress coping skills. Undoubtedly, virtual reality simulation training provides an alternative means of improving performance in laparoscopic surgery. However, future research efforts should focus on the effect of virtual reality simulation on performance in the context of advanced surgical procedure, on standardization of training, on the possibility of synergistic effect of virtual reality simulation training combined with mental training, on personalized training. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  1. Optical Imaging with a High Resolution Microendoscope to Identify Cholesteatoma of the Middle Ear

    PubMed Central

    Levy, Lauren L.; Jiang, Nancy; Smouha, Eric; Richards-Kortum, Rebecca; Sikora, Andrew G.

    2013-01-01

    Objective High resolution optical imaging is an imaging modality which allows visualization of structural changes in epithelial tissue in real time. Our prior studies using contrast-enhanced microendoscopy to image squamous cell carcinoma in the head and neck demonstrated that the contrast agent, proflavine, has high affinity for keratinized tissue. Thus, high-resolution microendoscopy with proflavine provides a potential mechanism to identify ectopic keratin production, such as that associated with cholesteatoma formation and distinguish between uninvolved mucosa and residual keratin at the time of surgery. Study Design Ex vivo imaging of histopathologically-confirmed samples of cholesteatoma and uninvolved middle-ear epithelium. Methods Seven separate specimens collected from patients who underwent surgical treatment for cholesteatoma were imaged ex vivo with the fiberoptic endoscope after surface staining with proflavine. Following imaging, the specimens were submitted for hematoxylin &eosin staining to allow histopathological correlation. Results Cholesteatoma and surrounding middle ear epithelium have distinct imaging characteristics. Keratin-bearing areas of cholesteatoma lack nuclei and appear as confluent hyperfluorescence, while nuclei are easily visualized in specimens containing normal middle ear epithelium. Hyperfluorescence and loss of cellular detail is the imaging hallmark of keratin allowing for discrimination of cholesteatoma from normal middle ear epithelium. Conclusions This study demonstrates the feasibility of high-resolution optical imaging to discriminate cholesteatoma from uninvolved middle ear mucosa, based on the unique staining properties of keratin. Use of real-time imaging may facilitate more complete extirpation of cholesteatoma by identifying areas of residual disease. PMID:23299781

  2. Ear Infections and Language Development.

    ERIC Educational Resources Information Center

    Roberts, Joanne E.; Zeisel, Susan A.

    Ear infections in infants and preschoolers can cause mild or moderate temporary hearing loss, which may in turn affect a child's ability to understand and learn language. Noting that providing children with proper medical treatment for ear infections or middle ear fluid is important in preventing possible problems with language development, this…

  3. Multimodal optical imager for inner ear hearing loss diagnosis (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Park, Jesung; Maguluri, Gopi N.; Zhao, Youbo; Iftimia, Nicusor V.

    2017-02-01

    Sensorineural hearing loss (SNHL), which typically originates in the cochlea, is the most common otologic problem caused by aging and noise trauma. The cochlea, a delicate and complex biological mechanosensory transducer in the inner ear, has been extensively studied with the goal of improving diagnosis of SNHL. However, the difficulty associated with accessing the cochlea and resolving the microstructures that facilitate hearing within it in a minimally-invasive way has prevented us from being able to assess the pathology underlying SNHL in humans. To address this problem we investigated the ability of a multimodal optical system that combines optical coherence tomography (OCT) and single photon autofluorescence imaging (AFI) to enable visualization and evaluation of microstructures in the cochlea. A laboratory OCT/AFI imager was built to acquire high resolution OCT and single photon fluorescence images of the cochlea. The imager's ability to resolve diagnostically-relevant details was evaluated in ears extracted from normal and noise-exposed mice. A prototype endoscopic OCT/AFI imager was developed based on a double-clad fiber approach. Our measurements show that the multimodal OCT/AFI imager can be used to evaluate structural integrity in the mouse cochlea. Therefore, we believe that this technology is promising as a potential clinical evaluation tool, and as a technique for guiding otologic surgeries such as cochlear implant surgery.

  4. Three-Dimensional Liver Surgery Simulation: Computer-Assisted Surgical Planning with Three-Dimensional Simulation Software and Three-Dimensional Printing.

    PubMed

    Oshiro, Yukio; Ohkohchi, Nobuhiro

    2017-06-01

    To perform accurate hepatectomy without injury, it is necessary to understand the anatomical relationship among the branches of Glisson's sheath, hepatic veins, and tumor. In Japan, three-dimensional (3D) preoperative simulation for liver surgery is becoming increasingly common, and liver 3D modeling and 3D hepatectomy simulation by 3D analysis software for liver surgery have been covered by universal healthcare insurance since 2012. Herein, we review the history of virtual hepatectomy using computer-assisted surgery (CAS) and our research to date, and we discuss the future prospects of CAS. We have used the SYNAPSE VINCENT medical imaging system (Fujifilm Medical, Tokyo, Japan) for 3D visualization and virtual resection of the liver since 2010. We developed a novel fusion imaging technique combining 3D computed tomography (CT) with magnetic resonance imaging (MRI). The fusion image enables us to easily visualize anatomic relationships among the hepatic arteries, portal veins, bile duct, and tumor in the hepatic hilum. In 2013, we developed an original software, called Liversim, which enables real-time deformation of the liver using physical simulation, and a randomized control trial has recently been conducted to evaluate the use of Liversim and SYNAPSE VINCENT for preoperative simulation and planning. Furthermore, we developed a novel hollow 3D-printed liver model whose surface is covered with frames. This model is useful for safe liver resection, has better visibility, and the production cost is reduced to one-third of a previous model. Preoperative simulation and navigation with CAS in liver resection are expected to help planning and conducting a surgery and surgical education. Thus, a novel CAS system will contribute to not only the performance of reliable hepatectomy but also to surgical education.

  5. Sustained supervised practice on a coronary anastomosis simulator increases medical student interest in surgery, unsupervised practice does not.

    PubMed

    Lou, Xiaoying; Enter, Daniel; Sheen, Luke; Adams, Katherine; Reed, Carolyn E; McCarthy, Patrick M; Calhoon, John H; Verrier, Edward D; Lee, Richard

    2013-06-01

    Given declining interest in cardiothoracic (CT) training programs during the last decade, increasing emphasis has been placed on engaging candidates early in their training. We examined the effect of supervised and unsupervised practice on medical students' interest in CT surgery. Forty-five medical students participated in this study. Participants' interest level in surgery, CT surgery, and simulation were collected before and after a pretest session. Subsequently, participants were randomized to one of three groups: control (n = 15), unsupervised training on a low-fidelity task simulator (n = 15), or supervised training with a CT surgeon or fellow on the same simulator (n = 15). After 3 weeks, attitudes were reassessed at a posttest session. Interest levels were compared before and after the pretest using paired t tests, and the effects of training on interests were assessed with multiple linear regression analyses. After the pretest session, participants were significantly more interested in simulation (p = 0.001) but not in surgery or CT surgery. After training, compared with control group participants, supervised trainees demonstrated a significant increase in their interest level in pursuing a career in surgery (p = 0.028) and an increasing trend towards a career in CT surgery (p = 0.060), whereas unsupervised trainees did not. Supervised training on low-fidelity simulators enhances interest in a career in surgery. Practice that lacks supervision does not, possibly related to the complexity of the simulated task. Mentorship efforts may need to involve sustained interaction to provide medical students with enough exposure to appreciate a surgical career. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Comparison of high-resolution microendoscope images and histopathological sections in ex vivo middle ear cholesteatomas and surrounding tissue

    NASA Astrophysics Data System (ADS)

    Bradley, James; Levy, Lauren; Richards-Kortum, Rebecca; Sikora, Andrew G.; Smouha, Eric

    2013-03-01

    Objective: To investigate the concordance between optical images obtained with high-resolution microendoscopy (HRME) and conventional histopathology for ex vivo cholesteatoma specimens and surrounding middle ear epithelium. Methods: After resection of cholesteatoma and surrounding middle ear epithelium from surgical patients, tissues were stained with a contrast agent, proflavine, and the HRME fiberoptic scope was placed directly on each tissue specimen. 4- 10 short movie clips were recorded for both the cholesteatoma and surrounding middle ear epithelium specimens. The imaged areas were sent for standard histopathology, and the stained specimens were correlated with the HRME images. IRB approval was obtained, and each patient was consented for the study. Results: Ten cholesteatoma specimens and 9 middle ear specimens were collected from 10 patients. In each case, cholesteatoma was easily discriminated from normal middle ear epithelium by its hyperfluorescence and loss of cellular detail. Qualitative analysis for concordance between HRME images and histological images from the same surgical specimen yielded a strong correlation between imaging modalities. Conclusions: Keratinizing cholesteatoma and surrounding middle ear epithelium have distinct imaging characteristics. Loss of cellular detail and hyperfluorescence with proflavine are the hallmark characteristics of cholesteatoma which allow for differentiation from normal middle ear epithelium. Real-time optical imaging can potentially improve the results of otologic surgery by allowing for extirpation of cholesteatomas while eliminating residual disease. We anticipate performing an in vivo study to test this hypothesis.

  7. CUDA-based real time surgery simulation.

    PubMed

    Liu, Youquan; De, Suvranu

    2008-01-01

    In this paper we present a general software platform that enables real time surgery simulation on the newly available compute unified device architecture (CUDA)from NVIDIA. CUDA-enabled GPUs harness the power of 128 processors which allow data parallel computations. Compared to the previous GPGPU, it is significantly more flexible with a C language interface. We report implementation of both collision detection and consequent deformation computation algorithms. Our test results indicate that the CUDA enables a twenty times speedup for collision detection and about fifteen times speedup for deformation computation on an Intel Core 2 Quad 2.66 GHz machine with GeForce 8800 GTX.

  8. Swimmer's Ear (External Otitis)

    MedlinePlus

    ... t help, your doctor might prescribe a stronger pain reliever. You'll use this only for a short time — until the ear drops and antibiotics begin to work. To protect your ear while it heals, your ...

  9. Ear molding in newborn infants with auricular deformities.

    PubMed

    Byrd, H Steve; Langevin, Claude-Jean; Ghidoni, Lorraine A

    2010-10-01

    A review of a single physician's experience in managing over 831 infant ear deformities (488 patients) is presented. The authors' methods of molding have advanced from the use of various tapes, glues, and stents, to a comprehensive yet simple system that shapes the antihelix, the triangular fossa, the helical rim, and the overly prominent conchal-mastoid angle (EarWell Infant Ear Correction System). The types of deformities managed, and their relative occurrence, are as follows: (1) prominent/cup ear, 373 ears (45 percent); (2) lidding/lop ear, 224 ears (27 percent); (3) mixed ear deformities, 83 ears (10 percent) (all had associated conchal crus); (4) Stahl's ear, 66 ears (8 percent); (5) helical rim abnormalities, 58 ears (7 percent); (6) conchal crus, 25 ears (3 percent); and (7) cryptotia, two ears (0.2 percent). Bilateral deformities were present in 340 patients (70 percent), with unilateral deformities in 148 patients (30 percent). Fifty-eight infant ears (34 patients) were treated using the final version of the EarWell Infant Ear Correction System with a success rate exceeding 90 percent (good to excellent results). The system was found to be most successful when begun in the first week of the infant's life. When molding was initiated after 3 weeks from birth, only approximately half of the infants had a good response. Congenital ear deformities are common and only approximately 30 percent self-correct. These deformities can be corrected by initiating appropriate molding in the first week of life. Neonatal molding reduces the need for surgical correction with results that often exceed what can be achieved with the surgical alternative.

  10. Fluid structure interaction simulations of the upper airway in obstructive sleep apnea patients before and after maxillomandibular advancement surgery.

    PubMed

    Chang, Kwang K; Kim, Ki Beom; McQuilling, Mark W; Movahed, Reza

    2018-06-01

    The purpose of this study was to analyze pharyngeal airflow using both computational fluid dynamics (CFD) and fluid structure interactions (FSI) in obstructive sleep apnea patients before and after maxillomandibular advancement (MMA) surgery. The airflow characteristics before and after surgery were compared with both CFD and FSI. In addition, the presurgery and postsurgery deformations of the airway were evaluated using FSI. Digitized pharyngeal airway models of 2 obstructive sleep apnea patients were generated from cone-beam computed tomography scans before and after MMA surgery. CFD and FSI were used to evaluate the pharyngeal airflow at a maximum inspiration rate of 166 ml per second. Standard steady-state numeric formulations were used for airflow simulations. Airway volume increased, pressure drop decreased, maximum airflow velocity decreased, and airway resistance dropped for both patients after the MMA surgery. These findings occurred in both the CFD and FSI simulations. The FSI simulations showed an area of marked airway deformation in both patients before surgery, but this deformation was negligible after surgery for both patients. Both CFD and FSI simulations produced airflow results that indicated less effort was needed to breathe after MMA surgery. The FSI simulations demonstrated a substantial decrease in airway deformation after surgery. These beneficial changes positively correlated with the large improvements in polysomnography outcomes after MMA surgery. Copyright © 2018 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  11. A prediction of the minke whale (Balaenoptera acutorostrata) middle-ear transfer functiona)

    PubMed Central

    Tubelli, Andrew A.; Zosuls, Aleks; Ketten, Darlene R.; Yamato, Maya; Mountain, David C.

    2012-01-01

    The lack of baleen whale (Cetacea Mysticeti) audiograms impedes the assessment of the impacts of anthropogenic noise on these animals. Estimates of audiograms, which are difficult to obtain behaviorally or electrophysiologically for baleen whales, can be made by simulating the audiogram as a series of components representing the outer, middle, and inner ear (Rosowski, 1991; Ruggero and Temchin, 2002). The middle-ear portion of the system can be represented by the middle-ear transfer function (METF), a measure of the transmission of acoustic energy from the external ear to the cochlea. An anatomically accurate finite element model of the minke whale (Balaenoptera acutorostrata) middle ear was developed to predict the METF for a mysticete species. The elastic moduli of the auditory ossicles were measured by using nanoindentation. Other mechanical properties were estimated from experimental stiffness measurements or from published values. The METF predicted a best frequency range between approximately 30 Hz and 7.5 kHz or between 100 Hz and 25 kHz depending on stimulation location. Parametric analysis found that the most sensitive parameters are the elastic moduli of the glove finger and joints and the Rayleigh damping stiffness coefficient β. The predicted hearing range matches well with the vocalization range. PMID:23145610

  12. A prediction of the minke whale (Balaenoptera acutorostrata) middle-ear transfer function.

    PubMed

    Tubelli, Andrew A; Zosuls, Aleks; Ketten, Darlene R; Yamato, Maya; Mountain, David C

    2012-11-01

    The lack of baleen whale (Cetacea Mysticeti) audiograms impedes the assessment of the impacts of anthropogenic noise on these animals. Estimates of audiograms, which are difficult to obtain behaviorally or electrophysiologically for baleen whales, can be made by simulating the audiogram as a series of components representing the outer, middle, and inner ear (Rosowski, 1991; Ruggero and Temchin, 2002). The middle-ear portion of the system can be represented by the middle-ear transfer function (METF), a measure of the transmission of acoustic energy from the external ear to the cochlea. An anatomically accurate finite element model of the minke whale (Balaenoptera acutorostrata) middle ear was developed to predict the METF for a mysticete species. The elastic moduli of the auditory ossicles were measured by using nanoindentation. Other mechanical properties were estimated from experimental stiffness measurements or from published values. The METF predicted a best frequency range between approximately 30 Hz and 7.5 kHz or between 100 Hz and 25 kHz depending on stimulation location. Parametric analysis found that the most sensitive parameters are the elastic moduli of the glove finger and joints and the Rayleigh damping stiffness coefficient β. The predicted hearing range matches well with the vocalization range.

  13. Inner Ear Drug Delivery for Auditory Applications

    PubMed Central

    Swan, Erin E. Leary; Mescher, Mark J.; Sewell, William F.; Tao, Sarah L.; Borenstein, Jeffrey T.

    2008-01-01

    Many inner ear disorders cannot be adequately treated by systemic drug delivery. A blood-cochlear barrier exists, similar physiologically to the blood-brain barrier, which limits the concentration and size of molecules able to leave the circulation and gain access to the cells of the inner ear. However, research in novel therapeutics and delivery systems has led to significant progress in the development of local methods of drug delivery to the inner ear. Intratympanic approaches, which deliver therapeutics to the middle ear, rely on permeation through tissue for access to the structures of the inner ear, whereas intracochlear methods are able to directly insert drugs into the inner ear. Innovative drug delivery systems to treat various inner ear ailments such as ototoxicity, sudden sensorineural hearing loss, autoimmune inner ear disease, and for preserving neurons and regenerating sensory cells are being explored. PMID:18848590

  14. Development and implementation of a clinical pathway approach to simulation-based training for foregut surgery

    PubMed Central

    Miyasaka, Kiyoyuki W; Buchholz, Joseph; LaMarra, Denise; Karakousis, Giorgos C; Aggarwal, Rajesh

    2015-01-01

    Introduction Contemporary demands on resident education call for integration of simulation. We designed and implemented a simulation-based curriculum for PGY1 surgery residents to teach technical and non-technical skills within a clinical pathway approach for a foregut surgical patient, from outpatient visit through surgery and post-op follow-up. Methods The three-day curriculum for groups of six residents comprises a combination of standardized patient (SP) encounters, didactic sessions, and hands-on training. The curriculum is underpinned by a summative simulation “pathway” repeated on days 1 and 3. The “pathway” is a series of simulated pre-op, intra-op, and post-op encounters following a single patient through a disease process. The resident sees an SP in clinic presenting with distal gastric cancer, then enters an operating room to perform a gastro-jejunostomy on a porcine tissue model. Finally, the resident engages in a simulated post-operative visit. All encounters are rated by faculty members and the residents themselves, using standardized assessment forms endorsed by the American Board of Surgery. Results 18 first-year residents underwent this curriculum. Faculty ratings of overall operative performance significantly improved following the three-day module. Ratings of preoperative and postoperative performance were not significantly changed in three days. Resident self-ratings significantly improved for all encounters assessed, as did reported confidence in meeting defined learning objectives. Conclusions Conventional surgical simulation training focuses on technical skills in isolation. Our novel “pathway” curriculum targets an important gap in training methodologies by placing both technical and non-technical skills in their clinical context as part of managing a surgical patient. Results indicate consistent improvements in assessments of performance as well as confidence and support its continued usage to educate surgery residents in

  15. Optimal Electromechanical Reshaping of the Auricular Ear and Long-term Outcomes in an In Vivo Rabbit Model

    PubMed Central

    Manuel, Cyrus T.; Tjoa, Tjoson; Nguyen, Tony; Su, Erica; Wong, Brian J. F.

    2016-01-01

    IMPORTANCE The prominent ear is a common external ear anomaly that is usually corrected through surgery. Electromechanical reshaping (EMR) may provide the means to reshape cartilage through the use of direct current (in milliamperes) applied percutaneously with needle electrodes and thus to reduce reliance on open surgery. OBJECTIVE To determine the long-term outcomes (shape change, cell viability, and histology) of a more refined EMR voltage and time settings for reshaping rabbit auricle. DESIGN, SETTING, AND SUBJECTS The intact ears of 14 New Zealand white rabbits were divided into 2 groups. Group 1 received 4 V for 5 minutes (5 ears), 5 V for 4 minutes (5 ears), or no voltage for 5 minutes (control; 4 ears). Group 2 received an adjusted treatment of 4 V for 4 minutes (7 ears) or 5 V for 3 minutes (7 ears). A custom mold with platinum electrodes was used to bend the pinna and to perform EMR. Pinnae were splinted for 6 months along the region of the bend. Rabbits were killed humanely and the ears were harvested the day after splint removal. Data were collected from March 14, 2013, to July 8, 2014, and analyzed from August 29, 2013, to March 1, 2015. MAIN OUTCOMES AND MEASURES Bend angle and mechanical behavior via palpation were recorded through photography and videography. Tissue was sectioned for histologic examination and confocal microscopy to assess changes to microscopic structure and cell viability. RESULTS Rabbits ranged in age from 6 to 8 months and weighed 3.8 to 4.0 g. The mean (SD) bend angles were 81° (45°) for the controls and, in the 5 EMR groups, 72° (29°) for 4 V for 4 minutes, 101° (19°) for 4 V for 5 minutes, 78° (18°) for 5 V for 3 minutes, and 126° (21°) for 5 V for 4 minutes. At 5 V, an increase in application time from 3 to 4 minutes provided significant shape change (78° [18°] and 126° [21°], respectively; P = .003). Pinnae stained with hematoxylin-eosin displayed localized areas of cell injury and fibrosis in and around

  16. Real-time simulation of soft tissue deformation and electrocautery procedures in laparoscopic rectal cancer radical surgery.

    PubMed

    Sui, Yuan; Pan, Jun J; Qin, Hong; Liu, Hao; Lu, Yun

    2017-12-01

    Laparoscopic surgery (LS), also referred to as minimally invasive surgery, is a modern surgical technique which is widely applied. The fulcrum effect makes LS a non-intuitive motor skill with a steep learning curve. A hybrid model of tetrahedrons and a multi-layer triangular mesh are constructed to simulate the deformable behavior of the rectum and surrounding tissues in the Position-Based Dynamics (PBD) framework. A heat-conduction based electric-burn technique is employed to simulate the electrocautery procedure. The simulator has been applied for laparoscopic rectum cancer surgery training. From the experimental results, trainees can operate in real time with high degrees of stability and fidelity. A preliminary study was performed to evaluate the realism and usefulness. This prototype simulator has been tested and verified by colorectal surgeons through a pilot study. They believed both the visual and the haptic performance of the simulation are realistic and helpful to enhance laparoscopic skills. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Robotic surgery basic skills training: Evaluation of a pilot multidisciplinary simulation-based curriculum

    PubMed Central

    Foell, Kirsten; Finelli, Antonio; Yasufuku, Kazuhiro; Bernardini, Marcus Q.; Waddell, Thomas K.; Pace, Kenneth T.; Honey, R. John D.’A.; Lee, Jason Y.

    2013-01-01

    Purpose: Simulation-based training improves clinical skills, while minimizing the impact of the educational process on patient care. We present results of a pilot multidisciplinary, simulation-based robotic surgery basic skills training curriculum (BSTC) for robotic novices. Methods: A 4-week, simulation-based, robotic surgery BSTC was offered to the Departments of Surgery and Obstetrics & Gynecology (ObGyn) at the University of Toronto. The course consisted of various instructional strategies: didactic lecture, self-directed online-training modules, introductory hands-on training with the da Vinci robot (dVR) (Intuitive Surgical Inc., Sunnyvale, CA), and dedicated training on the da Vinci Skills Simulator (Intuitive Surgical Inc., Sunnyvale, CA) (dVSS). A third of trainees participated in competency-based dVSS training, all others engaged in traditional time-based training. Pre- and post-course skill testing was conducted on the dVR using 2 standardized skill tasks: ring transfer (RT) and needle passing (NP). Retention of skills was assessed at 5 months post-BSTC. Results: A total of 37 participants completed training. The mean task completion time and number of errors improved significantly post-course on both RT (180.6 vs. 107.4 sec, p < 0.01 and 3.5 vs. 1.3 sec, p < 0.01, respectively) and NP (197.1 vs. 154.1 sec, p < 0.01 and 4.5 vs. 1.8 sec, p = 0.04, respectively) tasks. No significant difference in performance was seen between specialties. Competency-based training was associated with significantly better post-course performance. The dVSS demonstrated excellent face validity. Conclusions: The implementation of a pilot multidisciplinary, simulation-based robotic surgery BSTC revealed significantly improved basic robotic skills among novice trainees, regardless of specialty or level of training. Competency-based training was associated with significantly better acquisition of basic robotic skills. PMID:24381662

  18. Complications after Total Porous Implant Ear Reconstruction and Their Management.

    PubMed

    Lewin, Sheryl

    2015-12-01

    Microtia reconstruction using porous polyethylene implants has become an established alternative to autologous costal cartilage techniques. Few surgeons are trained in porous implant ear reconstruction (PIER), leading to a relative lack of understanding of the nuances of this type of surgery. The risks of exposure, infection, and fracture of the implant have further discouraged surgeons from performing PIERs. Meticulous technique and proper management of complications are critical to the success of surgeries involving porous implants (Medpor, Su-Por). There are a limited number of articles in the literature that report the management of complications of porous implant auricular reconstruction. The purpose of this work is to present a comprehensive review of the management of complications with PIER based on over 10 years of experience with this surgical technique. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Listening to the ear

    NASA Astrophysics Data System (ADS)

    Shera, Christopher A.

    Otoacoustic emissions demonstrate that the ear creates sound while listening to sound, offering a promising acoustic window on the mechanics of hearing in awake, listening human beings. That window is clouded, however, by an incomplete knowledge of wave reflection and transmission, both forth and back within the cochlea and through the middle ear. This thesis "does windows," addressing wave propagation and scattering on both sides of the middle ear. A summary of highlights follows. Measurements of the cochlear input impedance in cat are used to identify a new symmetry in cochlear mechanics-termed "tapering symmetry" after its geometric interpretation in simple models-that guarantees that the wavelength of the traveling wave changes slowly with position near the stapes. Waves therefore propagate without reflection through the basal turns of the cochlea. Analytic methods for solving the cochlear wave equations using a perturbative scattering series are given and used to demonstrate that, contrary to common belief, conventional cochlear models exhibit negligible internal reflection whether or not they accurately represent the tapering symmetries of the inner ear. Frameworks for the systematic "deconstruction" of eardrum and middle-ear transduction characteristics are developed and applied to the analysis of noninvasive measurements of middle-ear and cochlear mechanics. A simple phenomenological model of inner-ear compressibility that correctly predicts hearing thresholds in patients with missing or disarticulated middle-ear ossicles is developed and used to establish an upper bound on cochlear compressibility several orders of magnitude smaller than that provided by direct measurements. Accurate measurements of stimulus frequency evoked otoacoustic emissions are performed and used to determine the form and frequency variation of the cochlear traveling-wave ratio noninvasively. Those measurements are inverted to obtain the spatial distribution of mechanical

  20. Listening to the Ear

    NASA Astrophysics Data System (ADS)

    Shera, Christopher Alan

    Otoacoustic emissions demonstrate that the ear creates sound while listening to sound, offering a promising acoustic window on the mechanics of hearing in awake, listening human beings. That window is clouded, however, by an incomplete knowledge of wave reflection and transmission, both forth and back within the cochlea and through the middle ear. This thesis "does windows," addressing wave propagation and scattering on both sides of the middle ear. A summary of highlights follows. Measurements of the cochlear input impedance in cat are used to identify a new symmetry in cochlear mechanics--termed "tapering symmetry" after its geometric interpretation in simple models--that guarantees that the wavelength of the traveling wave changes slowly with position near the stapes. Waves therefore propagate without reflection through the basal turns of the cochlea. Analytic methods for solving the cochlear wave equations using a perturbative scattering series are given and used to demonstrate that, contrary to common belief, conventional cochlear models exhibit negligible internal reflection whether or not they accurately represent the tapering symmetries of the inner ear. Frameworks for the systematic "deconstruction" of eardrum and middle-ear transduction characteristics are developed and applied to the analysis of noninvasive measurements of middle-ear and cochlear mechanics. A simple phenomenological model of inner-ear compressibility that correctly predicts hearing thresholds in patients with missing or disarticulated middle-ear ossicles is developed and used to establish an upper bound on cochlear compressibility several orders of magnitude smaller than that provided by direct measurements. Accurate measurements of stimulus -frequency evoked otoacoustic emissions are performed and used to determine the form and frequency variation of the cochlear traveling-wave ratio noninvasively. Those measurements are inverted to obtain the spatial distribution of mechanical

  1. 3D-Printed Simulation Device for Orbital Surgery.

    PubMed

    Lichtenstein, Juergen Thomas; Zeller, Alexander Nicolai; Lemound, Juliana; Lichtenstein, Thorsten Enno; Rana, Majeed; Gellrich, Nils-Claudius; Wagner, Maximilian Eberhard

    Orbital surgery is a challenging procedure because of its complex anatomy. Training could especially benefit from dedicated study models. The currently available devices lack sufficient anatomical representation and realistic soft tissue properties. Hence, we developed a 3D-printed simulation device for orbital surgery with tactual (haptic) correct simulation of all relevant anatomical structures. Based on computed tomography scans collected from patients treated in a third referral center, the hard and soft tissue were segmented and virtually processed to generate a 3D-model of the orbit. Hard tissue was then physically realized by 3D-printing. The soft tissue was manufactured by a composite silicone model of the nucleus and the surrounding tissue over a negative mold model also generated by 3D-printing. The final model was evaluated by a group of 5 trainees in oral and maxillofacial surgery (1) and a group of 5 consultants (2). All participants were asked to reconstruct an isolated orbital floor defect with a titanium implant. A stereotactic navigation system was available to all participants. Their experience was evaluated for haptic realism, correct representation of surgical approach, general handling of model, insertion of implant into the orbit, placement and fixation of implant, and usability of navigated control. The items were evaluated via nonparametric statistics (1 [poor]-5 [good]). Group 1 gave an average mark of 4.0 (±0.9) versus 4.6 (±0.6) by group 2. The haptics were rated as 3.6 (±1.1) [1] and 4.2 (±0.8) [2]. The surgical approach was graded 3.7 (±1.2) [1] and 4.0 (±1.0) [2]. Handling of the models was rated 3.5 (±1.1) [1] and 4 (±0.7) [2]. The insertion of the implants was marked as 3.7 (±0.8) [1] and 4.2 (±0.8) [2]. Fixation of the implants was also perceived to be realistic with 3.6 (±0.9) [1] and 4.2 (±0.45) [2]. Lastly, surgical navigation was rated 3.8 (±0.8) [1] and 4.6 (±0.56) [2]. In this project, all relevant hard and soft

  2. Naturopathic treatment for ear pain in children.

    PubMed

    Sarrell, E Michael; Cohen, Herman Avner; Kahan, Ernesto

    2003-05-01

    included in the study and recorded all of the data. The presence or absence of ear pain was assessed over 3 days with a visual analog scale. Ear pain was assessed by a specially devised observational instrument based on previous reports. One side of the instrument consisted of a linear numbered scale, from 1 (no pain) to 10 (worst possible pain), and a corresponding color scale, ranging from blue to dark red. The reverse side contained a scale of 5 facial expressions, ranging from broad smile (no pain) to a sad and crying face (worst possible pain), and a corresponding color scale, ranging from blue to dark red. There were no significant between-group differences in patient age or gender, degree of fever, main symptoms, associated symptoms, and severity or laterality of acute otitis media. Each group had a statistically significant improvement in ear pain over the course of the 3 days. Patients who were given ear drops alone had a better response than patients who were given ear drops together with amoxicillin. Results were better in the NHED group than in the controls. Nevertheless, the findings indicated that the pain was mostly (80%) self-limited and could be explained simply by the time elapsed. The American Academy of Otolaryngology-Head and Neck Surgery guidelines recommend topical medications as the first line of treatment for ear pain in the absence of systemic infection or serious underlying disease. Because no evidence was found that systemic antibiotics alone improved treatment outcome, if antibiotics do not change the natural course of otitis media, then the main goal of treatment, as in the present study, should be to alleviate the ear pain. The alternative, naturopathic herbal extract medications, may offer many new possibilities in the management of ear pain associated with AOM. Primary care physicians should be aware that at least 10% of their patients may have tried 1 or more forms of alternative/complementary medicine before presenting for consultation

  3. A morphometric study of the human ear.

    PubMed

    Alexander, K Skaria; Stott, David J; Sivakumar, Branavan; Kang, Norbert

    2011-01-01

    We examined variations in the shape of the human ear according to age, sex and ethnic group with particular attention to ear prominence. 420 volunteers were recruited. Measurements included; head height and length, ear height and axis, antihelix taken off angle, earlobe length and width, ear width at the helical root and tragus. Prominence was measured at the helical root and tragus (conchomastoid angle, conchal bowl depth and helical-mastoid distance). Good symmetry was shown for all measurements. Ethnically Indian volunteers had the largest ears (both length and width), followed by Caucasians, and Afro-Caribbeans. This trend was significant in males (p<0.001), but not significant in females (p=0.087). Ears increased in size throughout life. Subjectively, only 2% of volunteers felt their ears were prominent compared to 10% in the opinion of the principal investigator. No objective measurements were identified that accurately predicted subjective perceptions of prominence. We found consistent trends in ear morphology depending on ethnic group, age and sex. Our study was unable to define an objective method for assessing ear prominence. Decisions about what constitutes a prominent ear should be left to personal and aesthetic choice. Copyright © 2010 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Outcomes of a virtual-reality simulator-training programme on basic surgical skills in robot-assisted laparoscopic surgery.

    PubMed

    Phé, Véronique; Cattarino, Susanna; Parra, Jérôme; Bitker, Marc-Olivier; Ambrogi, Vanina; Vaessen, Christophe; Rouprêt, Morgan

    2017-06-01

    The utility of the virtual-reality robotic simulator in training programmes has not been clearly evaluated. Our aim was to evaluate the impact of a virtual-reality robotic simulator-training programme on basic surgical skills. A simulator-training programme in robotic surgery, using the da Vinci Skills Simulator, was evaluated in a population including junior and seasoned surgeons, and non-physicians. Their performances on robotic dots and suturing-skin pod platforms before and after virtual-simulation training were rated anonymously by surgeons experienced in robotics. 39 participants were enrolled: 14 medical students and residents in surgery, 14 seasoned surgeons, 11 non-physicians. Junior and seasoned surgeons' performances on platforms were not significantly improved after virtual-reality robotic simulation in any of the skill domains, in contrast to non-physicians. The benefits of virtual-reality simulator training on several tasks to basic skills in robotic surgery were not obvious among surgeons in our initial and early experience with the simulator. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  5. Soft tissue modelling through autowaves for surgery simulation.

    PubMed

    Zhong, Yongmin; Shirinzadeh, Bijan; Alici, Gursel; Smith, Julian

    2006-09-01

    Modelling of soft tissue deformation is of great importance to virtual reality based surgery simulation. This paper presents a new methodology for simulation of soft tissue deformation by drawing an analogy between autowaves and soft tissue deformation. The potential energy stored in a soft tissue as a result of a deformation caused by an external force is propagated among mass points of the soft tissue by non-linear autowaves. The novelty of the methodology is that (i) autowave techniques are established to describe the potential energy distribution of a deformation for extrapolating internal forces, and (ii) non-linear materials are modelled with non-linear autowaves other than geometric non-linearity. Integration with a haptic device has been achieved to simulate soft tissue deformation with force feedback. The proposed methodology not only deals with large-range deformations, but also accommodates isotropic, anisotropic and inhomogeneous materials by simply changing diffusion coefficients.

  6. Optical imaging with a high-resolution microendoscope to identify cholesteatoma of the middle ear.

    PubMed

    Levy, Lauren L; Jiang, Nancy; Smouha, Eric; Richards-Kortum, Rebecca; Sikora, Andrew G

    2013-04-01

    High-resolution optical imaging is an imaging modality that allows visualization of structural changes in epithelial tissue in real time. Our prior studies using contrast-enhanced microendoscopy to image squamous cell carcinoma in the head and neck demonstrated that the contrast agent, proflavine, has high affinity for keratinized tissue. Thus, high-resolution microendoscopy with proflavine provides a potential mechanism to identify ectopic keratin production, such as that associated with cholesteatoma formation, and distinguish between uninvolved mucosa and residual keratin at the time of surgery. Ex vivo imaging of histopathologically confirmed samples of cholesteatoma and uninvolved middle ear epithelium. Seven separate specimens collected from patients who underwent surgical treatment for cholesteatoma were imaged ex vivo with the fiberoptic endoscope after surface staining with proflavine. Following imaging, the specimens were submitted for hematoxylin and eosin staining to allow histopathological correlation. Cholesteatoma and surrounding middle ear epithelium have distinct imaging characteristics. Keratin-bearing areas of cholesteatoma lack nuclei and appear as confluent hyperfluorescence, whereas nuclei are easily visualized in specimens containing normal middle ear epithelium. Hyperfluorescence and loss of cellular detail is the imaging hallmark of keratin, allowing for discrimination of cholesteatoma from normal middle ear epithelium. This study demonstrates the feasibility of high-resolution optical imaging to discriminate cholesteatoma from uninvolved middle ear mucosa based on the unique staining properties of keratin. Use of real-time imaging may facilitate more complete extirpation of cholesteatoma by identifying areas of residual disease. Laryngoscope, 2012. Copyright © 2013 The American Laryngological, Rhinological, and Otological Society, Inc.

  7. Audit of 117 otoplasties for prominent ear by one surgeon using a cartilage-cutting procedure.

    PubMed

    Brian, Tess; Cheng, Paul T; Loo, Stanley S

    2018-02-07

    The plethora of surgical procedures for prominent ear correction reflects lack of satisfaction with outcomes achieved. This paper describes a cartilage-cutting otoplasty procedure and reports an audit of its outcomes. Discharge coding was used to retrospectively identify patients who had undergone the otoplasty of interest at Middlemore Hospital, Auckland, during the 5 years from March 2010 to the end of February 2015. Hospital records were accessed. Demographic, procedure and patient satisfaction data were recorded and analysed (PASW/SPSS Statistics 18.0). Chi-square test and t-test were used to assess associations, with significance accepted at two-sided P < 0.05. Sixty-four patients underwent the specified otoplasty (54.7% females: mean age 9.5 years (standard deviation, SD: 4.2; range: 4-20)), of whom 93.8% had bilateral procedures with mean surgical time of 61 min (SD: 14; range: 34-94). This was significantly shorter (P < 0.001) than for bilateral surgeries by all other techniques and surgeons in the review period. None of the 117 procedures of interest subsequently had suture extrusion or revision surgery. Mean time from surgery to satisfaction determination was 993 days (SD: 521; range: 111-1850) for 43 (67.2%) patients. 23.3% believed that there had been aesthetically insignificant partial recurrence of prominence, typically of one ear only. This was insufficient for all but one patient to consider repeat otoplasty. Surgery outcome was rated 'very satisfactory' and 'satisfactory' by 90.7% and 9.3% of patients/parents, respectively. All would recommend the surgery to others. With infrequent complications and recurrence requiring revision, and without long-term reliance on sutures, the otoplasty reported is time-efficient, safe and generates high patient satisfaction. © 2018 Royal Australasian College of Surgeons.

  8. Listening to Nature's orchestra with peculiar ears

    NASA Astrophysics Data System (ADS)

    Yager, David D.

    2003-04-01

    Insects use hearing for the crucial tasks of communicating with conspecifics and avoiding predators. Although all are based on the same acoustic principles, the diversity of insect ears is staggering and instructive. For instance, a South African grasshopper demonstrates that hearing conspecific calls is possible over distances 1 km with ears that do not have tympana. Actually, these creatures have six pairs of ears that play different roles in behavior. In numerical contrast, praying mantises have just a single ear in the ventral midline. The ear is very effective at detecting ultrasonic bat cries. However, the bioacoustics of sound transduction by two tympana facing each other in a deep, narrow slit is a puzzle. Tachinid flies demonstrate that directional hearing at 5 kHz is possible with a pair of ears fused together to give a total size of 1 mm. The ears are under the fly's chin. Hawk moths have their ears built into their mouthparts and the tympanum is more like a hollow ball than the usual membrane. As an apt last example, cicada ears are actually part of the orchestra: their tympana function both in sound reception and sound production.

  9. Unclassified congenital deformities of the external ear.

    PubMed

    Vathulya, Madhubari

    2018-01-01

    Congenital ear deformities are a common entity. They are found in isolation or as a part of syndrome in patients. They may involve the external, middle or inner ear or in any of these combinations. Three patients of different ages presented with deformities including mirror image duplication of the superior auricle, unclassified deformities of ear lobule (wavy lobule) and deformity of superior auricle with unclassified variety of lateral ear pit. This article highlights that there are further cases of ear deformities that are noticed in the general population who come for cosmetic correction, and hence, there is a need for further modifying the classification of ear deformities.

  10. Ultrasound characterization of middle ear effusion.

    PubMed

    Seth, Rahul; Discolo, Christopher M; Palczewska, Grazyna M; Lewandowski, Jan J; Krakovitz, Paul R

    2013-01-01

    To further enhance and assess the ability to characterize middle ear effusion (MEE) using non-invasive ultrasound technology. This is a prospective unblinded comparison study. Fifty-six children between the ages of 6 months and 17 years scheduled to undergo bilateral myringotomy with pressure equalization tube placement were enrolled. With the child anesthetized, the probe was placed into the external ear canal after sterile water was inserted. Ultrasound recordings of middle ear contents were analyzed by computer algorithm. Middle ear fluid was collected during myringotomy and analyzed for bacterial culture and viscosity. Ultrasound waveforms yielded a computer algorithm interpretation of middle ear contents in 66% of ears tested. When a result was obtained, the sensitivity and specificity for successfully characterizing middle ear fluid content as either void of fluid, thick fluid (mucoid), or thin fluid (serous or purulent) were at least 94%. Mucoid effusions had higher measured viscosity values (P=.002). Viscosity measures were compared to culture result, and those with low viscosity (thin consistency) had a higher likelihood of having a positive culture (P=.048). The device sensitivity and specificity for fluid detection were 94% or greater among interpretable waveforms (66% of those tested). Although this technology provides important information of the middle ear effusion presence and characteristic, further technological improvements are needed. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Ultrasound Characterization of Middle Ear Effusion

    PubMed Central

    Seth, Rahul; Discolo, Christopher M; Palczewska, Grazyna M; Lewandowski, Jan J; Krakovitz, Paul R

    2012-01-01

    Purpose To further enhance and assess the ability to characterize middle ear effusion (MEE) using non-invasive ultrasound technology. Materials and Methods This is a prospective unblinded comparison study. Fifty-six children between the ages of 6 months and 17 years scheduled to undergo bilateral myringotomy with pressure equalization tube placement were enrolled. With the child anesthetized, the probe was placed into the external ear canal after sterile water was inserted. Ultrasound recordings of middle ear contents were analyzed by computer algorithm. Middle ear fluid was collected during myringotomy and analyzed for bacterial culture and viscosity. Results Ultrasound waveforms yielded a computer algorithm interpretation of middle ear contents in 66% of ears tested. When a result was obtained, the sensitivity and specificity for successfully characterizing middle ear fluid content as either void of fluid, thick fluid (mucoid), or thin fluid (serous or purulent) was at least 94%. Mucoid effusions had higher measured viscosity values (P=0.002). Viscosity measures were compared to culture result, and those with low viscosity (thin consistency) had a higher likelihood of having a positive culture (P=0.048). Conclusion The device sensitivity and specificity for fluid detection was 94% or greater among interpretable waveforms (66% of those tested). Although this technology provides important information of the middle ear effusion presence and characteristic, further technological improvements are needed. PMID:23084430

  12. Development of a Virtual Reality Simulator for Natural Orifice Translumenal Endoscopic Surgery (NOTES) Cholecystectomy Procedure.

    PubMed

    Ahn, Woojin; Dargar, Saurabh; Halic, Tansel; Lee, Jason; Li, Baichun; Pan, Junjun; Sankaranarayanan, Ganesh; Roberts, Kurt; De, Suvranu

    2014-01-01

    The first virtual-reality-based simulator for Natural Orifice Translumenal Endoscopic Surgery (NOTES) is developed called the Virtual Translumenal Endoscopic Surgery Trainer (VTESTTM). VTESTTM aims to simulate hybrid NOTES cholecystectomy procedure using a rigid scope inserted through the vaginal port. The hardware interface is designed for accurate motion tracking of the scope and laparoscopic instruments to reproduce the unique hand-eye coordination. The haptic-enabled multimodal interactive simulation includes exposing the Calot's triangle and detaching the gall bladder while performing electrosurgery. The developed VTESTTM was demonstrated and validated at NOSCAR 2013.

  13. CT imaging of the internal human ear: Test of a high resolution scanner

    NASA Astrophysics Data System (ADS)

    Bettuzzi, M.; Brancaccio, R.; Morigi, M. P.; Gallo, A.; Strolin, S.; Casali, F.; Lamanna, Ernesto; Ariù, Marilù

    2011-08-01

    During the course of 2009, in the framework of a project supported by the National Institute of Nuclear Physics, a number of tests were carried out at the Department of Physics of the University of Bologna in order to achieve a good quality CT scan of the internal human ear. The work was carried out in collaboration with the local “S. Orsola” Hospital in Bologna and a company (CEFLA) already involved in the production and commercialization of a CT scanner dedicated to dentistry. A laboratory scanner with a simple concept detector (CCD camera-lens-mirror-scintillator) was used to see to what extent it was possible to enhance the quality of a conventional CT scanner when examining the internal human ear. To test the system, some conventional measurements were made, such as the spatial resolution calculation with the MTF and dynamic range evaluation. Different scintillators were compared to select the most suitable for the purpose. With 0.5 mm thick structured cesium iodide and a field of view of 120×120 mm2, a spatial resolution of 6.5l p/mm at 5% MTF was obtained. The CT of a pair of human head phantoms was performed at an energy of 120 kVp. The first phantom was a rough representation of the human head shape, with soft tissue made of coarse slabs of Lucite. Some inserts, like small aluminum cylinders and cubes, with 1 mm diameter drilled holes, were used to simulate the channels that one finds inside the human inner ear. The second phantom is a plastic PVC fused head with a real human cranium inside. The bones in the cranium are well conserved and the inner ear features, such as the cochlea and semicircular channels, are clearly detectable. After a number of CT tests we obtained good results as far as structural representation and channel detection are concerned. Some images of the 3D rendering of the CT volume are shown below. The doctors of the local hospital who followed our experimentation expressed their satisfaction. The CT was compared to a virtual

  14. Otogenic Meningitis: A Comparison of Diagnostic Performance of Surgery and Radiology.

    PubMed

    Bruschini, Luca; Fortunato, Simona; Tascini, Carlo; Ciabotti, Annalisa; Leonildi, Alessandro; Bini, Belinda; Giuliano, Simone; Abbruzzese, Arturo; Berrettini, Stefano; Menichetti, Francesco

    2017-01-01

    Development of intracranial complications from middle ear infections might be difficult to diagnose. We compared radiological and surgical findings of 26 patients affected by otogenic meningitis. Results of our analysis showed that surgery is more reliable than imaging in revealing bone defects. Therefore, suggest that surgery be performed for diagnosis and eventual management of all cases of suspected otogenic meningitis.

  15. Correction of lower lid retraction combined with entropion using an ear cartilage graft in the anophthalmic socket.

    PubMed

    Moon, Jun Woong; Choung, Ho Kyung; Khwarg, Sang In

    2005-09-01

    To investigate the surgical results of an ear cartilage graft and supplemental procedures for correcting lower lid retraction combined with entropion in anophthalmic patients. We reviewed retrospectively the medical records of 7 anophthalmic patients with lower lid retraction and entropion, who received a posterior lamellar ear cartilage graft and one or both of lateral tarsal strip or eyelash-everting procedure between March 1998 and March 2003. Preoperative and postoperative lid and socket statuses were also investigated. Ear cartilage grafts were performed in all 7 patients, lateral tarsal strips in 6, and eyelash-everting procedures in 5. Postoperative follow-up durations ranged from 4 to 28 months (average 12.6 months). Retractions were corrected during follow-up in all patients. There were no cases of entropion immediately after surgery. However, the eyelashes of the lower lid returned to an upright position in 4 patients, but not so severe as to touch the ocular prosthesis, and thus did not require surgical correction during follow up. Lower lid retraction combined with entropion in anophthalmic patients can be corrected effectively using an ear cartilage graft with selective, supplemental procedures.

  16. Is Attention Shared Between the Ears?1

    PubMed Central

    Shiffrin, Richard M.; Pisoni, David B.; Castaneda-Mendez, Kicab

    2012-01-01

    This study tests the locus of attention during selective listening for speech-like stimuli. Can processing be differentially allocated to the two ears? Two conditions were used. The simultaneous condition involved one of four randomly chosen stop-consonants being presented to one of the ears chosen at random. The sequential condition involved two intervals; in the first S listened to the right ear; in the second S listened to the left ear. One of the four consonants was presented to an attended ear during one of these intervals. Experiment I used no distracting stimuli. Experiment II utilized a distracting consonant not confusable with any of the four target consonants. This distractor was always presented to any ear not containing a target. In both experiments, simultaneous and sequential performance were essentially identical, despite the need for attention sharing between the two ears during the simultaneous condition. We conclude that selective attention does not occur during perceptual processing of speech sounds presented to the two ears. We suggest that attentive effects arise in short-term memory following processing. PMID:23226838

  17. Single-Stage Ear Reconstruction and Hearing Restoration Using Polyethylene Implant and Implantable Hearing Devices.

    PubMed

    Hempel, John Martin

    2015-12-01

    The use of porous polyethylene in reconstructive surgery of the auricle is becoming increasingly accepted. This is a single-stage procedure providing pleasing cosmetic rehabilitation. Further advantages are the possibility of early implantation and the lack of complications caused by harvesting costal cartilage. Additional hearing restoration using middle ear implants allows functional rehabilitation at an early stage. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. 21 CFR 870.2710 - Ear oximeter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ear oximeter. 870.2710 Section 870.2710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2710 Ear oximeter. (a) Identification. An ear...

  19. Can Loud Music Hurt My Ears?

    MedlinePlus

    ... Videos for Educators Search English Español Can Loud Music Hurt My Ears? KidsHealth / For Kids / Can Loud Music Hurt My Ears? Print en español La música ... up? Oh! You want to know if loud music can hurt your ears . Are you asking because ...

  20. 21 CFR 870.2710 - Ear oximeter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear oximeter. 870.2710 Section 870.2710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2710 Ear oximeter. (a) Identification. An ear...

  1. Status of Microsurgical Simulation Training in Plastic Surgery: A Survey of United States Program Directors.

    PubMed

    Al-Bustani, Saif; Halvorson, Eric G

    2016-06-01

    Various simulation models for microsurgery have been developed to overcome the limitations of Halstedian training on real patients. We wanted to assess the status of microsurgery simulation in plastic surgery residency programs in the United States. Data were analyzed from responses to a survey sent to all plastic surgery program directors in the United States, asking for type of simulation, quality of facilities, utilization by trainees, evaluation of trainee sessions, and perception of the relevance of simulation. The survey response rate was 50%. Of all programs, 69% provide microsurgical simulation and 75% of these have a laboratory with microscope and 52% provide live animal models. Half share facilities with other departments. The quality of facilities is rated as good or great in 89%. Trainee utilization is once every 3 to 6 months in 82% of programs. Only in 11% is utilization monthly. Formal evaluation of simulation sessions is provided by 41% of programs. All program directors agree simulation is relevant to competence in microsurgery, 60% agree simulation should be mandatory, and 43% require trainees to complete a formal microsurgery course prior to live surgery. There seems to be consensus that microsurgical simulation improves competence, and the majority of program directors agree it should be mandatory. Developing and implementing standardized simulation modules and assessment tools for trainees across the nation as part of a comprehensive competency-based training program for microsurgery is an important patient safety initiative that should be considered. Organizing with other departments to share facilities may improve their quality and hence utilization.

  2. Mixed reality simulation of rasping procedure in artificial cervical disc replacement (ACDR) surgery.

    PubMed

    Halic, Tansel; Kockara, Sinan; Bayrak, Coskun; Rowe, Richard

    2010-10-07

    Until quite recently spinal disorder problems in the U.S. have been operated by fusing cervical vertebrae instead of replacement of the cervical disc with an artificial disc. Cervical disc replacement is a recently approved procedure in the U.S. It is one of the most challenging surgical procedures in the medical field due to the deficiencies in available diagnostic tools and insufficient number of surgical practices For physicians and surgical instrument developers, it is critical to understand how to successfully deploy the new artificial disc replacement systems. Without proper understanding and practice of the deployment procedure, it is possible to injure the vertebral body. Mixed reality (MR) and virtual reality (VR) surgical simulators are becoming an indispensable part of physicians' training, since they offer a risk free training environment. In this study, MR simulation framework and intricacies involved in the development of a MR simulator for the rasping procedure in artificial cervical disc replacement (ACDR) surgery are investigated. The major components that make up the MR surgical simulator with motion tracking system are addressed. A mixed reality surgical simulator that targets rasping procedure in the artificial cervical disc replacement surgery with a VICON motion tracking system was developed. There were several challenges in the development of MR surgical simulator. First, the assembly of different hardware components for surgical simulation development that involves knowledge and application of interdisciplinary fields such as signal processing, computer vision and graphics, along with the design and placements of sensors etc . Second challenge was the creation of a physically correct model of the rasping procedure in order to attain critical forces. This challenge was handled with finite element modeling. The third challenge was minimization of error in mapping movements of an actor in real model to a virtual model in a process called

  3. Air-Leak Effects on Ear-Canal Acoustic Absorbance

    PubMed Central

    Rasetshwane, Daniel M.; Kopun, Judy G.; Gorga, Michael P.; Neely, Stephen T.

    2015-01-01

    Objective: Accurate ear-canal acoustic measurements, such as wideband acoustic admittance, absorbance, and otoacoustic emissions, require that the measurement probe be tightly sealed in the ear canal. Air leaks can compromise the validity of the measurements, interfere with calibrations, and increase variability. There are no established procedures for determining the presence of air leaks or criteria for what size leak would affect the accuracy of ear-canal acoustic measurements. The purpose of this study was to determine ways to quantify the effects of air leaks and to develop objective criteria to detect their presence. Design: Air leaks were simulated by modifying the foam tips that are used with the measurement probe through insertion of thin plastic tubing. To analyze the effect of air leaks, acoustic measurements were taken with both modified and unmodified foam tips in brass-tube cavities and human ear canals. Measurements were initially made in cavities to determine the range of critical leaks. Subsequently, data were collected in ears of 21 adults with normal hearing and normal middle-ear function. Four acoustic metrics were used for predicting the presence of air leaks and for quantifying these leaks: (1) low-frequency admittance phase (averaged over 0.1–0.2 kHz), (2) low-frequency absorbance, (3) the ratio of compliance volume to physical volume (CV/PV), and (4) the air-leak resonance frequency. The outcome variable in this analysis was the absorbance change (Δabsorbance), which was calculated in eight frequency bands. Results: The trends were similar for both the brass cavities and the ear canals. ΔAbsorbance generally increased with air-leak size and was largest for the lower frequency bands (0.1–0.2 and 0.2–0.5 kHz). Air-leak effects were observed in frequencies up to 10 kHz, but their effects above 1 kHz were unpredictable. These high-frequency air leaks were larger in brass cavities than in ear canals. Each of the four predictor variables

  4. Air-leak effects on ear-canal acoustic absorbance.

    PubMed

    Groon, Katherine A; Rasetshwane, Daniel M; Kopun, Judy G; Gorga, Michael P; Neely, Stephen T

    2015-01-01

    Accurate ear-canal acoustic measurements, such as wideband acoustic admittance, absorbance, and otoacoustic emissions, require that the measurement probe be tightly sealed in the ear canal. Air leaks can compromise the validity of the measurements, interfere with calibrations, and increase variability. There are no established procedures for determining the presence of air leaks or criteria for what size leak would affect the accuracy of ear-canal acoustic measurements. The purpose of this study was to determine ways to quantify the effects of air leaks and to develop objective criteria to detect their presence. Air leaks were simulated by modifying the foam tips that are used with the measurement probe through insertion of thin plastic tubing. To analyze the effect of air leaks, acoustic measurements were taken with both modified and unmodified foam tips in brass-tube cavities and human ear canals. Measurements were initially made in cavities to determine the range of critical leaks. Subsequently, data were collected in ears of 21 adults with normal hearing and normal middle-ear function. Four acoustic metrics were used for predicting the presence of air leaks and for quantifying these leaks: (1) low-frequency admittance phase (averaged over 0.1-0.2 kHz), (2) low-frequency absorbance, (3) the ratio of compliance volume to physical volume (CV/PV), and (4) the air-leak resonance frequency. The outcome variable in this analysis was the absorbance change (Δabsorbance), which was calculated in eight frequency bands. The trends were similar for both the brass cavities and the ear canals. ΔAbsorbance generally increased with air-leak size and was largest for the lower frequency bands (0.1-0.2 and 0.2-0.5 kHz). Air-leak effects were observed in frequencies up to 10 kHz, but their effects above 1 kHz were unpredictable. These high-frequency air leaks were larger in brass cavities than in ear canals. Each of the four predictor variables exhibited consistent dependence on

  5. Immunologic Disorders of the Inner Ear.

    ERIC Educational Resources Information Center

    Kinney, William C.; Hughes, Gordon B.

    1997-01-01

    Immune inner ear disease represents a series of immune system mediated problems that can present with hearing loss, dizziness, or both. The etiology, presentation, testing, and treatment of primary immune inner ear disease is discussed. A review of secondary immune inner ear disease is presented for comparison. (Contains references.) (Author/CR)

  6. Computer Simulation Shows the Effect of Communication on Day of Surgery Patient Flow.

    PubMed

    Taaffe, Kevin; Fredendall, Lawrence; Huynh, Nathan; Franklin, Jennifer

    2015-07-01

    To improve patient flow in a surgical environment, practitioners and academicians often use process mapping and simulation as tools to evaluate and recommend changes. We used simulations to help staff visualize the effect of communication and coordination delays that occur on the day of surgery. Perioperative services staff participated in tabletop exercises in which they chose the delays that were most important to eliminate. Using a day-of-surgery computer simulation model, the elimination of delays was tested and the results were shared with the group. This exercise, repeated for multiple groups of staff, provided an understanding of not only the dynamic events taking place, but also how small communication delays can contribute to a significant loss in efficiency and the ability to provide timely care. Survey results confirmed these understandings. Copyright © 2015 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  7. 3D Printed Bionic Ears

    PubMed Central

    Mannoor, Manu S.; Jiang, Ziwen; James, Teena; Kong, Yong Lin; Malatesta, Karen A.; Soboyejo, Winston O.; Verma, Naveen; Gracias, David H.; McAlpine, Michael C.

    2013-01-01

    The ability to three-dimensionally interweave biological tissue with functional electronics could enable the creation of bionic organs possessing enhanced functionalities over their human counterparts. Conventional electronic devices are inherently two-dimensional, preventing seamless multidimensional integration with synthetic biology, as the processes and materials are very different. Here, we present a novel strategy for overcoming these difficulties via additive manufacturing of biological cells with structural and nanoparticle derived electronic elements. As a proof of concept, we generated a bionic ear via 3D printing of a cell-seeded hydrogel matrix in the precise anatomic geometry of a human ear, along with an intertwined conducting polymer consisting of infused silver nanoparticles. This allowed for in vitro culturing of cartilage tissue around an inductive coil antenna in the ear, which subsequently enables readout of inductively-coupled signals from cochlea-shaped electrodes. The printed ear exhibits enhanced auditory sensing for radio frequency reception, and complementary left and right ears can listen to stereo audio music. Overall, our approach suggests a means to intricately merge biologic and nanoelectronic functionalities via 3D printing. PMID:23635097

  8. 3D printed bionic ears.

    PubMed

    Mannoor, Manu S; Jiang, Ziwen; James, Teena; Kong, Yong Lin; Malatesta, Karen A; Soboyejo, Winston O; Verma, Naveen; Gracias, David H; McAlpine, Michael C

    2013-06-12

    The ability to three-dimensionally interweave biological tissue with functional electronics could enable the creation of bionic organs possessing enhanced functionalities over their human counterparts. Conventional electronic devices are inherently two-dimensional, preventing seamless multidimensional integration with synthetic biology, as the processes and materials are very different. Here, we present a novel strategy for overcoming these difficulties via additive manufacturing of biological cells with structural and nanoparticle derived electronic elements. As a proof of concept, we generated a bionic ear via 3D printing of a cell-seeded hydrogel matrix in the anatomic geometry of a human ear, along with an intertwined conducting polymer consisting of infused silver nanoparticles. This allowed for in vitro culturing of cartilage tissue around an inductive coil antenna in the ear, which subsequently enables readout of inductively-coupled signals from cochlea-shaped electrodes. The printed ear exhibits enhanced auditory sensing for radio frequency reception, and complementary left and right ears can listen to stereo audio music. Overall, our approach suggests a means to intricately merge biologic and nanoelectronic functionalities via 3D printing.

  9. Patient satisfaction and aesthetic outcomes after ear reconstruction with a Branemark-type, bone-anchored, ear prosthesis: a 16 year review.

    PubMed

    Younis, Ibby; Gault, David; Sabbagh, Walid; Kang, Norbert V

    2010-10-01

    Reconstruction of the human ear with a bone-anchored prosthesis is a widely accepted alternative when autologous reconstruction is technically impossible or declined by the individual. However, there are relatively few data in the literature documenting patient satisfaction with this form of reconstruction. This study examines different aspects of patient satisfaction using an eighteen-point postal questionnaire to measure patient outcomes against a Likert rating scale. The questionnaire was sent to 33 patients who completed prosthetic ear reconstruction over a 16 year period at a specialist plastic surgery unit in the United Kingdom. Medical case notes for these cases were also reviewed. Twenty completed questionnaires were returned. The response rate was 61%. The majority of patients were satisfied with the aesthetics, ease of handling and comfort of the bone-anchored implant and prosthesis. However, the majority of patients was only moderately satisfied or was dissatisfied with this method of reconstruction. Specifically, 15 of the respondents reported skin problems around the abutments of the bone-anchored implant with 10 patients reporting ongoing skin complications. Granulation tissue was the most common skin problem (12 cases) followed by local infection (10 cases). Interestingly, despite the chronic skin problems, most patients indicated that they would undergo the same procedure again or would recommend it to others. Our survey shows that patients fitted with a Branemark-type bone-anchored implant for ear reconstruction are pleased with the aesthetic appearance but experience multiple, chronic, skin complications and other implant related problems. These affect their satisfaction with this method of reconstruction. Our findings may have significant implications for patients and surgeons considering this form of reconstruction and for the institutions making decisions about funding this treatment. Copyright 2009. Published by Elsevier Ltd.

  10. A different type of 'glue ear': report of an unusual case of prominent ears.

    PubMed

    Purcell, Elizabeth M; O'Neill, Ann C; Regan, Padraic J

    2003-09-01

    Prominent ears is a condition that can cause extreme psychological distress in young people. This cosmetic deformity can be corrected by otoplasty, an outpatient surgical procedure that is associated with a high rate of patient satisfaction. We report the unusual case of a teenage boy who had repeatedly applied cyanoacrylate adhesive ("superglue") to his postauricular skin in an attempt to pin back his prominent ears. This case of "glue ear" was ultimately resolved by successful otoplasty, although the residual effects of the glue resulted in delayed healing of the surgical wound.

  11. What Is an Ear Infection?

    MedlinePlus

    ... Hearing Loss? Taking Care of Your Ears Swimmer's Ear Perforated Eardrum What's Earwax? View ... All information on KidsHealth® is for educational purposes only. For specific medical advice, diagnoses, and treatment, ...

  12. [Atypical inflammation of the middle ear].

    PubMed

    Garov, E V; Kryukov, A I; Zelenkova, V N; Sidorina, N G; Kaloshina, A S

    The objective of the present study was to characterize the patients presenting with atypical inflammation of the middle ear and consider the currently available methods for their examination. A total of 20 patients at the age from 16 to 66 years were admitted to the Department of Ear Microsurgery during the period from 2008 and 2016 for the treatment of atypical inflammation of the middle ear. Eleven of them (18 ears) were found to have tuberculous lesions (TL) of the middle ear while the remaining 9 patients (11 ears) suffered giant cell vasculitis (GCV). All the patients underwent the general clinical and otorhinolaryngological examination, computed tomography of the temporal bones and the thoracic cavity organs, cytological, bacteriological, pathomorphological, and molecular-genetic studies including PCR diagnostics, rheumatological tests, as well as counseling by a phthisiotherapist and rheumatologist. The primary localization of TL in the middle ear was documented in 6 patients including its association with lung lesions in 5 cases. The clinical picture of the disease in 5 patients was that of smoldering exudative pathology and in 6 ones was accompanied by suppurative perforative otitis media. According to the laboratory analyses, bacteriological diagnostics proved efficient in 9% of the patients, pathomorphological and cytological diagnostics in 18% and 27.3% of the cases respectively while the effectiveness of PCR diagnostics was estimated at 55%. The diagnosis in individual patients was established within the period from 1 month to 1.5 years after they first sought medical advice in connection with complaints of the ear disease. Tuberculosis of the middle ear began to develop as exudative middle otitis that acquired the form of bilateral pathology in 4 patients. Three patients had a concomitant pulmonary disease. In 4 patuents, the diagnois of middle ear tuberculosis was established based on the presence of the specific antibodies and in 5 ones based on the

  13. Effect of absorbable gelatin sponge in the middle ear: in vitro and in vivo animal model.

    PubMed

    Goncalves, Stefania; Chiossone-Kerdel, Juan Armando; Bianco, Andrea S; Ercolino, Jose M; Hernandez-Rojas, Jorge

    2015-01-01

    GelitaSpon gelatin sponge (GS) showed faster reabsorption than gelfoam (GF) in vitro, and GS-packed middle ears resulted in a faster hearing recovery and less inflammation than the ears packed with GF soaked in saline. Soaking GF sponges with boric acid (BA) appeared to offset the inflammatory response of saline-soaked GF, making this inflammatory response comparable to that of GS-packed ears. To describe the reabsorption and inflammatory effects of absorbable gelatin sponge in the middle ear. For in vitro evaluation, GF and GS were used as disks immersed in saline solution or 3% BA and placed in gel. Images were captured with a microscope and processed using image processing Toolbox. For in vivo tests, 16 female albino Sprague Dawley rats were divided into four groups: bulla opening; GF + 0.9% saline; GF + BA; and GS + 0.9% saline. An anterior approach to the right bulla was used for surgery. Preoperative and postoperative auditory brainstem response thresholds were measured. In vitro, there was marked degradation of GF by day 14, while GS showed complete degradation by the third day. In vivo, hearing recovery occurred by day 21. GF produced a more severe inflammatory response, which could be reduced by treating the GF with BA.

  14. Ear - blocked at high altitudes

    MedlinePlus

    ... ears; Flying and blocked ears; Eustachian tube dysfunction - high altitude ... to the eardrum) and the back of the nose and upper throat. ... down from high altitudes. Chewing gum the entire time you are ...

  15. The McGill simulator for endoscopic sinus surgery (MSESS): a validation study.

    PubMed

    Varshney, Rickul; Frenkiel, Saul; Nguyen, Lily H P; Young, Meredith; Del Maestro, Rolando; Zeitouni, Anthony; Saad, Elias; Funnell, W Robert J; Tewfik, Marc A

    2014-10-24

    Endoscopic sinus surgery (ESS) is a technically challenging procedure, associated with a significant risk of complications. Virtual reality simulation has demonstrated benefit in many disciplines as an important educational tool for surgical training. Within the field of rhinology, there is a lack of ESS simulators with appropriate validity evidence supporting their integration into residency education. The objectives of this study are to evaluate the acceptability, perceived realism and benefit of the McGill Simulator for Endoscopic Sinus Surgery (MSESS) among medical students, otolaryngology residents and faculty, and to present evidence supporting its ability to differentiate users based on their level of training through the performance metrics. 10 medical students, 10 junior residents, 10 senior residents and 3 expert sinus surgeons performed anterior ethmoidectomies, posterior ethmoidectomies and wide sphenoidotomies on the MSESS. Performance metrics related to quality (e.g. percentage of tissue removed), efficiency (e.g. time, path length, bimanual dexterity, etc.) and safety (e.g. contact with no-go zones, maximum applied force, etc.) were calculated. All users completed a post-simulation questionnaire related to realism, usefulness and perceived benefits of training on the MSESS. The MSESS was found to be realistic and useful for training surgical skills with scores of 7.97 ± 0.29 and 8.57 ± 0.69, respectively on a 10-point rating scale. Most students and residents (29/30) believed that it should be incorporated into their curriculum. There were significant differences between novice surgeons (10 medical students and 10 junior residents) and senior surgeons (10 senior residents and 3 sinus surgeons) in performance metrics related to quality (p < 0.05), efficiency (p < 0.01) and safety (p < 0.05). The MSESS demonstrated initial evidence supporting its use for residency education. This simulator may be a potential resource to help fill

  16. Klippel-Feil syndrome and associated ear anomalies.

    PubMed

    Yildirim, Nadir; Arslanoğlu, Atilla; Mahiroğullari, Mahir; Sahan, Murat; Ozkan, Hüseyin

    2008-01-01

    Klippel-Feil syndrome (KFS) is a congenital segmentation anomaly of the cervical vertebrae that manifests as short neck, low hair line, and limited neck mobility. Various systemic malformations may also accompany the syndrome including wide variety of otopathologies affecting all 3 compartments of the ear (external, middle, and inner ear) as well as internal acoustic canal and vestibular aqueduct. We aimed to investigate these involvements and their clinical correlates in a group of patients with KFS. We present 20 KFS cases, of which 12 (% 60) displayed most of the reported ear abnormalities such as microtia, external ear canal stenosis, chronic ear inflammations and their sequels, anomalies of the tympanic cavity and ossicles, inner ear dysplasies, deformed internal acoustic canal, and wide vestibular aqueduct, which are demonstrated using the methods of otoscopy, audiologic testing, and temporal bone computed tomography. This series represents one of the highest reported rate of ear involvement in KFS. We found no correlation between the identified ear pathologies and the skeletal and extraskeletal malformations. The genetic nature of the syndrome was supported by the existence of affected family members in 4 (20%) of the cases.

  17. Procedural virtual reality simulation in minimally invasive surgery.

    PubMed

    Våpenstad, Cecilie; Buzink, Sonja N

    2013-02-01

    Simulation of procedural tasks has the potential to bridge the gap between basic skills training outside the operating room (OR) and performance of complex surgical tasks in the OR. This paper provides an overview of procedural virtual reality (VR) simulation currently available on the market and presented in scientific literature for laparoscopy (LS), flexible gastrointestinal endoscopy (FGE), and endovascular surgery (EVS). An online survey was sent to companies and research groups selling or developing procedural VR simulators, and a systematic search was done for scientific publications presenting or applying VR simulators to train or assess procedural skills in the PUBMED and SCOPUS databases. The results of five simulator companies were included in the survey. In the literature review, 116 articles were analyzed (45 on LS, 43 on FGE, 28 on EVS), presenting a total of 23 simulator systems. The companies stated to altogether offer 78 procedural tasks (33 for LS, 12 for FGE, 33 for EVS), of which 17 also were found in the literature review. Although study type and used outcomes vary between the three different fields, approximately 90 % of the studies presented in the retrieved publications for LS found convincing evidence to confirm the validity or added value of procedural VR simulation. This was the case in approximately 75 % for FGE and EVS. Procedural training using VR simulators has been found to improve clinical performance. There is nevertheless a large amount of simulated procedural tasks that have not been validated. Future research should focus on the optimal use of procedural simulators in the most effective training setups and further investigate the benefits of procedural VR simulation to improve clinical outcome.

  18. Abdominal surgery process modeling framework for simulation using spreadsheets.

    PubMed

    Boshkoska, Biljana Mileva; Damij, Talib; Jelenc, Franc; Damij, Nadja

    2015-08-01

    We provide a continuation of the existing Activity Table Modeling methodology with a modular spreadsheets simulation. The simulation model developed is comprised of 28 modeling elements for the abdominal surgery cycle process. The simulation of a two-week patient flow in an abdominal clinic with 75 beds demonstrates the applicability of the methodology. The simulation does not include macros, thus programming experience is not essential for replication or upgrading the model. Unlike the existing methods, the proposed solution employs a modular approach for modeling the activities that ensures better readability, the possibility of easily upgrading the model with other activities, and its easy extension and connectives with other similar models. We propose a first-in-first-served approach for simulation of servicing multiple patients. The uncertain time duration of the activities is modeled using the function "rand()". The patients movements from one activity to the next one is tracked with nested "if()" functions, thus allowing easy re-creation of the process without the need of complex programming. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  19. Transmission matrix analysis of the chinchilla middle ear

    PubMed Central

    Songer, Jocelyn E.; Rosowski, John J.

    2008-01-01

    Despite the common use of the chinchilla as an animal model in auditory research, a complete characterization of the chinchilla middle ear using transmission matrix analysis has not been performed. In this paper we describe measurements of middle-ear input admittance and stapes velocity in ears with the middle-ear cavity opened under three conditions: intact tympano-ossicular system and cochlea, after the cochlea has been drained, and after the stapes has been fixed. These measurements, made with stimulus frequencies of 100–8000 Hz, are used to define the transmission matrix parameters of the middle ear and to calculate the cochlear input impedance as well as the middle-ear output impedance. This transmission characterization of the chinchilla middle ear will be useful for modeling auditory sensitivity in the normal and pathological chinchilla ear. PMID:17672642

  20. Treating "cauliflower ear" with silicone mold.

    PubMed

    Gross, C G

    1978-01-01

    Acute hematoma of the ear (cauliflower ear) can be satisfactorily treated with aspiration and the use of the silicone mold to prevent reaccumulation of the blood or serum in the ear. Advantages of the silicone mold over other dressings appears to be ease of application, patient acceptance, and prevention of reoccurrence of reaccumulation of the hematoma.

  1. Communication routes between intracranial spaces and inner ear: function, pathophysiologic importance and relations with inner ear diseases.

    PubMed

    Ciuman, Raphael R

    2009-01-01

    There exist 3 communication routes between the intracranial space and the inner ear, the vestibular aqueduct, the cochlear aqueduct, and the internal auditory canal. They possess a key role in inner ear pressure regulation and fluid homeostasis and are related to inner ear diseases. Relevant literature was reviewed, and the current knowledge of the anatomy, physiologic importance, and relations to inner ear diseases were described. Pathologic communication routes such as semicircular canal dehiscence syndrome were highlighted as well. Abnormalities in all 3 communication routes may predispose or be the cause of distinct inner ear pathologic condition and involved in other cochlear and vestibular syndromes, in which their role is not completely clear. The increasing knowledge of the underlying mechanisms encourages promising approaches for possible intervention in the future.

  2. Bed Capacity Planning Using Stochastic Simulation Approach in Cardiac-surgery Department of Teaching Hospitals, Tehran, Iran

    PubMed Central

    TORABIPOUR, Amin; ZERAATI, Hojjat; ARAB, Mohammad; RASHIDIAN, Arash; AKBARI SARI, Ali; SARZAIEM, Mahmuod Reza

    2016-01-01

    Background: To determine the hospital required beds using stochastic simulation approach in cardiac surgery departments. Methods: This study was performed from Mar 2011 to Jul 2012 in three phases: First, collection data from 649 patients in cardiac surgery departments of two large teaching hospitals (in Tehran, Iran). Second, statistical analysis and formulate a multivariate linier regression model to determine factors that affect patient's length of stay. Third, develop a stochastic simulation system (from admission to discharge) based on key parameters to estimate required bed capacity. Results: Current cardiac surgery department with 33 beds can only admit patients in 90.7% of days. (4535 d) and will be required to over the 33 beds only in 9.3% of days (efficient cut off point). According to simulation method, studied cardiac surgery department will requires 41–52 beds for admission of all patients in the 12 next years. Finally, one-day reduction of length of stay lead to decrease need for two hospital beds annually. Conclusion: Variation of length of stay and its affecting factors can affect required beds. Statistic and stochastic simulation model are applied and useful methods to estimate and manage hospital beds based on key hospital parameters. PMID:27957466

  3. Molecular Mechanisms of Inner Ear Development

    PubMed Central

    Wu, Doris K.; Kelley, Matthew W.

    2012-01-01

    The inner ear is a structurally complex vertebrate organ built to encode sound, motion, and orientation in space. Given its complexity, it is not surprising that inner ear dysfunction is a relatively common consequence of human genetic mutation. Studies in model organisms suggest that many genes currently known to be associated with human hearing impairment are active during embryogenesis. Hence, the study of inner ear development provides a rich context for understanding the functions of genes implicated in hearing loss. This chapter focuses on molecular mechanisms of inner ear development derived from studies of model organisms. PMID:22855724

  4. Molecular mechanisms of inner ear development.

    PubMed

    Wu, Doris K; Kelley, Matthew W

    2012-08-01

    The inner ear is a structurally complex vertebrate organ built to encode sound, motion, and orientation in space. Given its complexity, it is not surprising that inner ear dysfunction is a relatively common consequence of human genetic mutation. Studies in model organisms suggest that many genes currently known to be associated with human hearing impairment are active during embryogenesis. Hence, the study of inner ear development provides a rich context for understanding the functions of genes implicated in hearing loss. This chapter focuses on molecular mechanisms of inner ear development derived from studies of model organisms.

  5. Middle ear impedance measurements in large vestibular aqueduct syndrome.

    PubMed

    Bilgen, Cem; Kirkim, Günay; Kirazli, Tayfun

    2009-06-01

    To assess the effect of inner ear pressure on middle ear impedance in patients with large vestibular aqueduct syndrome (LVAS). Data from admittance tympanometry and multifrequency tympanometry on 8 LVAS patients and control subjects were studied. Static acoustic compliance (SAC) values for the ears with stable sensorineural hearing loss (SNHL) were within the limits of the mean values of control groups except for two ears. The resonance frequency (RF) values of the ears with stable SNHL were lower than the mean values of control groups except for three ears. SAC values for the two ears with fluctuating SNHL were lower and the RF values were higher than the mean values of control groups. Decreased SAC values and increased RF values found in the ears with fluctuating SNHL might be an indirect indicator of increased inner ear pressure, while low RF values in the ears with stable SNHL might reflect the decreased inner ear impedance.

  6. Deriving the real-ear SPL of audiometric data using the "coupler to dial difference" and the "real ear to coupler difference".

    PubMed

    Munro, K J; Davis, J

    2003-04-01

    The purpose of the study was to compare the measured real-ear sound pressure level (SPL) of audiometer output with the derived real-ear SPL obtained by adding the coupler to dial difference (CDD) and real-ear to coupler difference (RECD) to the audiometer dial reading. The real-ear SPL and RECD were measured in one ear of 16 normally hearing subjects using a probe-tube microphone. The CDD transform and the RECD transfer function were measured in an HA1 and an HA2 2-cc coupler using an EAR-LINK foam ear-tip or a customized earmold. The RECD transfer function was measured using the EARTone ER 3A and the Audioscan RE770 insert earphone. The procedures were very reliable with mean differences on retest of less than 1 dB. The mean difference between the measured and derived real-ear SPL was generally less than 1 dB and rarely exceeded 3 dB in any subject. The CDD measured for an individual audiometer and the RECD measured for an individual ear can be used to derive a valid estimate of real-ear SPL when it has not been possible to measure this directly.

  7. Comparison of Microbiological Flora in the External Auditory Canal of Normal Ear and an Ear with Acute Otitis Externa.

    PubMed

    Ghanpur, Asheesh Dora; Nayak, Dipak Ranjan; Chawla, Kiran; Shashidhar, V; Singh, Rohit

    2017-09-01

    Acute Otitis Externa (AOE) is also known as swimmer's ear. Investigations initiated during World War II firmly established the role of bacteria in the aetiology of Acute Otitis Externa. To culture the microbiological flora of the normal ear and compare it with the flora causing AOE and to know the role of normal ear canal flora and anaerobes in the aetiology. A prospective observational study was conducted on 64 patients clinically diagnosed with unilateral AOE. Ear swabs were taken from both the ears. Microbiological flora was studied considering diseased ear as test ear and the normal ear as the control. Aerobic and anaerobic cultures were done. Severity of the disease was assessed by subjective and objective scores. Effect of topical treatment with ichthammol glycerine pack was assessed after 48 hours and scores were calculated again. Patients with scores < 4 after pack removal were started on systemic antibiotics and were assessed after seven days of antibiotics course. Data was analysed using Paired t-test, Wilcoxon signed ranks test and Chi-square test. A p-value < 0.05 was considered significant. Pseudomonas aeruginosa (33%) was the most common bacteria cultured from the ear followed by Methicillin Resistant Staphylococcus aureus (MRSA) (18%). Patients with anaerobic organism in the test ear had severe symptoms and needed systemic antibiotic therapy. Most of the cases may respond to empirical antibiotic therapy. In cases with severe symptoms and the ones refractory to empirical treatment, a culture from the ear canal will not be a tax on the patient. This helps in giving a better understanding about the disease, causative organisms and helps in avoiding the use of inappropriate antibiotics that usually result in developing resistant strains of bacteria.

  8. Validation of ergonomic instructions in robot-assisted surgery simulator training.

    PubMed

    Van't Hullenaar, C D P; Mertens, A C; Ruurda, J P; Broeders, I A M J

    2018-05-01

    Training in robot-assisted surgery focusses mainly on technical skills and instrument use. Training in optimal ergonomics during robotic surgery is often lacking, while improved ergonomics can be one of the key advantages of robot-assisted surgery. Therefore, the aim of this study was to assess whether a brief explanation on ergonomics of the console can improve body posture and performance. A comparative study was performed with 26 surgical interns and residents using the da Vinci skills simulator (Intuitive Surgical, Sunnyvale, CA). The intervention group received a compact instruction on ergonomic settings and coaching on clutch usage, while the control group received standard instructions for usage of the system. Participants performed two sets of five exercises. Analysis was performed on ergonomic score (RULA) and performance scores provided by the simulator. Mental and physical load scores (NASA-TLX and LED score) were also registered. The intervention group performed better in the clutch-oriented exercises, displaying less unnecessary movement and smaller deviation from the neutral position of the hands. The intervention group also scored significantly better on the RULA ergonomic score in both the exercises. No differences in overall performance scores and subjective scores were detected. The benefits of a brief instruction on ergonomics for novices are clear in this study. A single session of coaching and instruction leads to better ergonomic scores. The control group showed often inadequate ergonomic scores. No significant differences were found regarding physical discomfort, mental task load and overall performance scores.

  9. Evaluation of response variables in computer-simulated virtual cataract surgery

    NASA Astrophysics Data System (ADS)

    Söderberg, Per G.; Laurell, Carl-Gustaf; Simawi, Wamidh; Nordqvist, Per; Skarman, Eva; Nordh, Leif

    2006-02-01

    We have developed a virtual reality (VR) simulator for phacoemulsification (phaco) surgery. The current work aimed at evaluating the precision in the estimation of response variables identified for measurement of the performance of VR phaco surgery. We identified 31 response variables measuring; the overall procedure, the foot pedal technique, the phacoemulsification technique, erroneous manipulation, and damage to ocular structures. Totally, 8 medical or optometry students with a good knowledge of ocular anatomy and physiology but naive to cataract surgery performed three sessions each of VR Phaco surgery. For measurement, the surgical procedure was divided into a sculpting phase and an evacuation phase. The 31 response variables were measured for each phase in all three sessions. The variance components for individuals and iterations of sessions within individuals were estimated with an analysis of variance assuming a hierarchal model. The consequences of estimated variabilities for sample size requirements were determined. It was found that generally there was more variability for iterated sessions within individuals for measurements of the sculpting phase than for measurements of the evacuation phase. This resulted in larger required sample sizes for detection of difference between independent groups or change within group, for the sculpting phase as compared to for the evacuation phase. It is concluded that several of the identified response variables can be measured with sufficient precision for evaluation of VR phaco surgery.

  10. Middle-ear velocity transfer function, cochlear input immittance, and middle-ear efficiency in chinchilla.

    PubMed

    Ravicz, Michael E; Rosowski, John J

    2013-10-01

    The transfer function H(V) between stapes velocity V(S) and sound pressure near the tympanic membrane P(TM) is a descriptor of sound transmission through the middle ear (ME). The ME power transmission efficiency (MEE), the ratio of sound power entering the cochlea to power entering the middle ear, was computed from H(V) measured in seven chinchilla ears and previously reported measurements of ME input admittance Y(TM) and ME pressure gain G(MEP) [Ravicz and Rosowski, J. Acoust. Soc. Am. 132, 2437-2454 (2012); J. Acoust. Soc. Am. 133, 2208-2223 (2013)] in the same ears. The ME was open, and a pressure sensor was inserted into the cochlear vestibule for most measurements. The cochlear input admittance Y(C) computed from H(V) and G(MEP) is controlled by a combination of mass and resistance and is consistent with a minimum-phase system up to 27 kHz. The real part Re{Y(C)}, which relates cochlear sound power to inner-ear sound pressure, decreased gradually with frequency up to 25 kHz and more rapidly above that. MEE was about 0.5 between 0.1 and 8 kHz, higher than previous estimates in this species, and decreased sharply at higher frequencies.

  11. Middle-ear velocity transfer function, cochlear input immittance, and middle-ear efficiency in chinchilla

    PubMed Central

    Ravicz, Michael E.; Rosowski, John J.

    2013-01-01

    The transfer function HV between stapes velocity VS and sound pressure near the tympanic membrane PTM is a descriptor of sound transmission through the middle ear (ME). The ME power transmission efficiency (MEE), the ratio of sound power entering the cochlea to power entering the middle ear, was computed from HV measured in seven chinchilla ears and previously reported measurements of ME input admittance YTM and ME pressure gain GMEP [Ravicz and Rosowski, J. Acoust. Soc. Am. 132, 2437–2454 (2012); J. Acoust. Soc. Am. 133, 2208–2223 (2013)] in the same ears. The ME was open, and a pressure sensor was inserted into the cochlear vestibule for most measurements. The cochlear input admittance YC computed from HV and GMEP is controlled by a combination of mass and resistance and is consistent with a minimum-phase system up to 27 kHz. The real part Re{YC}, which relates cochlear sound power to inner-ear sound pressure, decreased gradually with frequency up to 25 kHz and more rapidly above that. MEE was about 0.5 between 0.1 and 8 kHz, higher than previous estimates in this species, and decreased sharply at higher frequencies. PMID:24116422

  12. [Melorheostosis associated with arteriovenous malformation of the ear].

    PubMed

    Ingen-Housz-Oro, S; Chigot, V; Hamel-Teillac, D; Brunelle, F; De Prost, Y

    2001-09-01

    Melorheostosis is a rare bone dystrophy that may be associated with various vascular malformations. We report a case of arteriovenous fistulae of the ear associated with melorheostosis limited to the same side of the body. A 13 year-old boy presented a congenital port-wine nevus of the right side of the head complicated by an arteriovenous fistulae and angiomatous nodules of the ear. He was treated by laser, surgery of the nodules, arterial embolisations and sclerotherapy. In 1999, he had a benign trauma of the right hand. The X-ray showed hyperostosis resembling wax flowing down a candle reaching the carpus and some of the metacarpals and the phalanges of the right hand, typical of melorheostosis. The complete radiographic check-up showed the same characteristic appearance on the right side of the skull and the long bones of the right upper limb. Except a deformation of the right fingers, there were no others symptoms. Melorheostosis is a rare, sporadic and benign bone dysplasia that may be localized to a single limb or disseminated. The diagnosis is usually made in late childhood. Pain, stiffness, deformation of a limb are the main clinical manifestations. The skin may be erythematous and sclerotic. The radiographic appearance is characteristic with hyperostosis on one side of the bone resembling wax flowing down a candle. A vascular abnormality is present in 17 p. 100 of cases (hemangiomas, aneurysms, renal artery stenosis.). In these cases, melorheostosis is usually limited to the same side of the vascular lesion. We report the first case of arteriovenous fistulae of the ear associated with melorheostosis, on the same side of the body. The physiopathology of melorheostosis is still unknown but the association with a homolateral vascular abnormality suggests a localized defect in embryogenesis of the vascular and skeletal systems.

  13. Efficacy of custom-made pressure clips for ear keloid treatment after surgical excision.

    PubMed

    Tanaydin, V; Beugels, J; Piatkowski, A; Colla, C; van den Kerckhove, E; Hugenholtz, G C G; van der Hulst, R R

    2016-01-01

    Mechanical pressure is increasingly applied as a means to prevent or treat keloid scars. The aim of this study is to analyze the long-term efficacy of our custom-molded pressure-adjustable earclips to prevent keloid recurrence after surgical excision. Using our custom-molded earclip, 88 patients who had undergone ear surgery for keloid scars were treated for 12 h a day for 6-18 months. The mean follow-up was 6.5 years. The primary outcome was the recurrence of keloids with patient satisfaction being the secondary outcome as assessed by Patient and Observer Scale (POSAS). Keloid scars did not recur in 70.5% of treated patients. The Fitzpatrick scale, which classifies human skin by type, was significantly different between the recurrence and nonrecurrence group. Differences in other patient characteristics were not found between both groups. All parameters mentioned in the POSAS patient scale drastically improved after therapy. There were no severe side effects observed after the therapy. Our pressure-adjustable earclip model is an effective tool in the prevention of ear keloid recurrence and is associated with high patient satisfaction. Its benefits should prompt further studies on its value as an adjuvant therapy to surgery in keloid treatment. Level III on the Evidence Rating Scale for Therapeutic Studies. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. Psychosocial outcome of patients after ear reconstruction: a retrospective study of 62 patients.

    PubMed

    Horlock, Nigel; Vögelin, Esther; Bradbury, Eileen T; Grobbelaar, Adriaan O; Gault, David T

    2005-05-01

    This was a retrospective study examining the psychosocial morbidity of patients before and after ear reconstruction. Semistructured questionnaires were sent to 90 patents with significant congenital or acquired auricular deformity 2.2 years (range 3 months to 5 years) following autogenous or osteointegrated reconstruction. Sixty-two patients (69%) responded. Twenty-two of the patients below 12 years, who had undergone reconstructive surgery, also completed the Childhood Experience Questionnaire. These were compared with a cohort of 362 normal patients. There was significant psychosocial morbidity in both children and adults with auricular deformity. Seventy-one percent of patients reported reduced self-confidence that affected both social life and leisure activity. Teasing was a prominent symptom in both children (88%) and adults (85%) but was a motivational factor for surgery in children only. Dissatisfaction with the appearance (73.1%), on the other hand, was the main reason for treatment in adults. Following ear reconstruction, 74% of adults and 91% of children reported an improvement in self-confidence resulting in enhanced social life and leisure activities in both adults and children. There was no difference between osteointegrated and autogenous reconstruction. Sixty percent of patients reported their result as excellent. The patients scored their result better than the surgeon. We conclude that auricular reconstruction has significant psychosocial benefit in the majority of children and adults despite donor-site morbidity and a range of technical result.

  15. Big Stimulus, Little Ears: Safety in Administering Vestibular-Evoked Myogenic Potentials in Children.

    PubMed

    Thomas, Megan L A; Fitzpatrick, Denis; McCreery, Ryan; Janky, Kristen L

    2017-05-01

    Cervical and ocular vestibular-evoked myogenic potentials (VEMPs) have become common clinical vestibular assessments. However, VEMP testing requires high intensity stimuli, raising concerns regarding safety with children, where sound pressure levels may be higher due to their smaller ear canal volumes. The purpose of this study was to estimate the range of peak-to-peak equivalent sound pressure levels (peSPLs) in child and adult ears in response to high intensity stimuli (i.e., 100 dB normal hearing level [nHL]) commonly used for VEMP testing and make a determination of whether acoustic stimuli levels with VEMP testing are safe for use in children. Prospective experimental. Ten children (4-6 years) and ten young adults (24-35 years) with normal hearing sensitivity and middle ear function participated in the study. Probe microphone peSPL measurements of clicks and 500 Hz tonebursts (TBs) were recorded in tubes of small, medium, and large diameter, and in a Brüel & Kjær Ear Simulator Type 4157 to assess for linearity of the stimulus at high levels. The different diameter tubes were used to approximate the range of cross-sectional areas in infant, child, and adult ears, respectively. Equivalent ear canal volume and peSPL measurements were then recorded in child and adult ears. Lower intensity levels were used in the participant's ears to limit exposure to high intensity sound. The peSPL measurements in participant ears were extrapolated using predictions from linear mixed models to determine if equivalent ear canal volume significantly contributed to overall peSPL and to estimate the mean and 95% confidence intervals of peSPLs in child and adult ears when high intensity stimulus levels (100 dB nHL) are used for VEMP testing without exposing subjects to high-intensity stimuli. Measurements from the coupler and tubes suggested: 1) each stimuli was linear, 2) there were no distortions or nonlinearities at high levels, and 3) peSPL increased with decreased tube diameter

  16. Using virtual reality simulation to assess competence in video-assisted thoracoscopic surgery (VATS) lobectomy.

    PubMed

    Jensen, Katrine; Bjerrum, Flemming; Hansen, Henrik Jessen; Petersen, René Horsleben; Pedersen, Jesper Holst; Konge, Lars

    2017-06-01

    The societies of thoracic surgery are working to incorporate simulation and competency-based assessment into specialty training. One challenge is the development of a simulation-based test, which can be used as an assessment tool. The study objective was to establish validity evidence for a virtual reality simulator test of a video-assisted thoracoscopic surgery (VATS) lobectomy of a right upper lobe. Participants with varying experience in VATS lobectomy were included. They were familiarized with a virtual reality simulator (LapSim ® ) and introduced to the steps of the procedure for a VATS right upper lobe lobectomy. The participants performed two VATS lobectomies on the simulator with a 5-min break between attempts. Nineteen pre-defined simulator metrics were recorded. Fifty-three participants from nine different countries were included. High internal consistency was found for the metrics with Cronbach's alpha coefficient for standardized items of 0.91. Significant test-retest reliability was found for 15 of the metrics (p-values <0.05). Significant correlations between the metrics and the participants VATS lobectomy experience were identified for seven metrics (p-values <0.001), and 10 metrics showed significant differences between novices (0 VATS lobectomies performed) and experienced surgeons (>50 VATS lobectomies performed). A pass/fail level defined as approximately one standard deviation from the mean metric scores for experienced surgeons passed none of the novices (0 % false positives) and failed four of the experienced surgeons (29 % false negatives). This study is the first to establish validity evidence for a VATS right upper lobe lobectomy virtual reality simulator test. Several simulator metrics demonstrated significant differences between novices and experienced surgeons and pass/fail criteria for the test were set with acceptable consequences. This test can be used as a first step in assessing thoracic surgery trainees' VATS lobectomy

  17. CT of the ear in Pendred syndrome.

    PubMed

    Goldfeld, Moshe; Glaser, Benjamin; Nassir, Elias; Gomori, John Moshe; Hazani, Elitsur; Bishara, Nassir

    2005-05-01

    To prospectively determine the structural anomalies of the inner ear by using thin-section computed tomography (CT) in an extended family with Pendred syndrome. Ethics committee approved the study, and informed consent was obtained from every patient or from parents of patients under legal age. Twelve patients (three females and nine males aged 7-47 years) with Pendred syndrome (all from the same ethnic isolate and with the same mutation in the PDS gene) were evaluated for inner-ear malformation at thin-section CT. Both ears were evaluated. Presence or absence of interscalar septum between upper and middle turns of the cochlea was evaluated, and vestibule and vestibular aqueduct were examined for enlargement. Modiolus was determined to be present or absent (modiolar deficiency). CT scans were evaluated in consensus by two radiologists (M.G., J.M.G.). All patients had inner ear malformation on both sides. Modiolus was absent and vestibule was enlarged on both sides in all 12 patients. Interscalar septum was absent in 18 (75%) of 24 ears. In eight patients, interscalar septum was absent in both ears, whereas in two patients, it was absent on only one side. Aqueduct was enlarged in 20 (80%) of 24 ears. In nine patients, both ears had enlarged aqueducts, while in two patients, only one side was abnormal. Inner ear malformation is an invariable finding in Pendred syndrome. Modiolus deficiency and vestibular enlargement were the most consistent anomalies in this population with Pendred syndrome. (c) RSNA, 2005.

  18. Stem Cell Therapy for the Inner Ear

    PubMed Central

    Okano, Takayuki

    2012-01-01

    In vertebrates, perception of sound, motion, and balance is mediated through mechanosensory hair cells located within the inner ear. In mammals, hair cells are only generated during a short period of embryonic development. As a result, loss of hair cells as a consequence of injury, disease, or genetic mutation, leads to permanent sensory deficits. At present, cochlear implantation is the only option for profound hearing loss. However, outcomes are still variable and even the best implant cannot provide the acuity of a biological ear. The recent emergence of stem cell technology has the potential to open new approaches for hair cell regeneration. The goal of this review is to summarize the current state of inner ear stem cell research from a viewpoint of its clinical application for inner ear disorders to illustrate how complementary studies have the potential to promote and refine stem cell therapies for inner ear diseases. The review initially discusses our current understanding of the genetic pathways that regulate hair cell formation from inner ear progenitors during normal development. Subsequent sections discuss the possible use of endogenous inner ear stem cells to induce repair as well as the initial studies aimed at transplanting stem cells into the ear. PMID:22514095

  19. Extended lateral thoracic fasciocutaneous biosynthetic flap for reconstruction of full-thickness partial external ear defects: an experimental study.

    PubMed

    Kuvat, Samet Vasfi; Taşkın, Ümit; Yücebaş, Kadir; Tansuker, Hasan Deniz; Oktay, Mehmet Faruk; Kozanoğlu, Erol; Aydın, Salih

    2017-01-01

    External ear reconstruction is a controversial topic in reconstructive plastic surgery. Here, we prepared a pedicled biosynthetic flap for full-thickness, partial ear defects in rabbits. We operated on six adult female New Zealand rabbits weighing 3-4 kg. The dimensions of the lateral thoracic fasciocutaneous flap were 7 × 6 cm. The flap was elevated based on one of the bilaterally located internal thoracic arteries, which were dissected proximally. The pedicled flap was folded in two, and polypropylene mesh was sandwiched in the middle. The flap was adapted to a defect of 3.5 × 3 cm in diameter. In fact, the defect was created before elevation of the flap. Rabbits were followed up for 4 weeks, at the end of which they were killed and their ears were evaluated histopathologically. The survival rate of the rabbits was 100 %. All pedicled biosynthetic flaps were viable, but one showed partial (20 %) necrosis (1/6) and one was partially detached (1/6). Macroscopic (color, thickness, texture) and histological (polymorphonuclear leukocyte invasion in the skin, subcutaneous tissue, and at the junction between the polypropylene mesh and the flap) features of the flap were compared to the ipsilateral ear. A new technique was developed for partial external ear reconstruction with sufficient inner skeletal support and outer skin lining. Level of evidence Level NA.

  20. Mixed reality simulation of rasping procedure in artificial cervical disc replacement (ACDR) surgery

    PubMed Central

    2010-01-01

    Background Until quite recently spinal disorder problems in the U.S. have been operated by fusing cervical vertebrae instead of replacement of the cervical disc with an artificial disc. Cervical disc replacement is a recently approved procedure in the U.S. It is one of the most challenging surgical procedures in the medical field due to the deficiencies in available diagnostic tools and insufficient number of surgical practices For physicians and surgical instrument developers, it is critical to understand how to successfully deploy the new artificial disc replacement systems. Without proper understanding and practice of the deployment procedure, it is possible to injure the vertebral body. Mixed reality (MR) and virtual reality (VR) surgical simulators are becoming an indispensable part of physicians’ training, since they offer a risk free training environment. In this study, MR simulation framework and intricacies involved in the development of a MR simulator for the rasping procedure in artificial cervical disc replacement (ACDR) surgery are investigated. The major components that make up the MR surgical simulator with motion tracking system are addressed. Findings A mixed reality surgical simulator that targets rasping procedure in the artificial cervical disc replacement surgery with a VICON motion tracking system was developed. There were several challenges in the development of MR surgical simulator. First, the assembly of different hardware components for surgical simulation development that involves knowledge and application of interdisciplinary fields such as signal processing, computer vision and graphics, along with the design and placements of sensors etc . Second challenge was the creation of a physically correct model of the rasping procedure in order to attain critical forces. This challenge was handled with finite element modeling. The third challenge was minimization of error in mapping movements of an actor in real model to a virtual model in a

  1. NOViSE: a virtual natural orifice transluminal endoscopic surgery simulator.

    PubMed

    Korzeniowski, Przemyslaw; Barrow, Alastair; Sodergren, Mikael H; Hald, Niels; Bello, Fernando

    2016-12-01

    Natural orifice transluminal endoscopic surgery (NOTES) is a novel technique in minimally invasive surgery whereby a flexible endoscope is inserted via a natural orifice to gain access to the abdominal cavity, leaving no external scars. This innovative use of flexible endoscopy creates many new challenges and is associated with a steep learning curve for clinicians. We developed NOViSE-the first force-feedback-enabled virtual reality simulator for NOTES training supporting a flexible endoscope. The haptic device is custom-built, and the behaviour of the virtual flexible endoscope is based on an established theoretical framework-the Cosserat theory of elastic rods. We present the application of NOViSE to the simulation of a hybrid trans-gastric cholecystectomy procedure. Preliminary results of face, content and construct validation have previously shown that NOViSE delivers the required level of realism for training of endoscopic manipulation skills specific to NOTES. VR simulation of NOTES procedures can contribute to surgical training and improve the educational experience without putting patients at risk, raising ethical issues or requiring expensive animal or cadaver facilities. In the context of an experimental technique, NOViSE could potentially facilitate NOTES development and contribute to its wider use by keeping practitioners up to date with this novel surgical technique. NOViSE is a first prototype, and the initial results indicate that it provides promising foundations for further development.

  2. Variability of the temporal bone surface's topography: implications for otologic surgery

    NASA Astrophysics Data System (ADS)

    Lecoeur, Jérémy; Noble, Jack H.; Balachandran, Ramya; Labadie, Robert F.; Dawant, Benoit M.

    2012-02-01

    Otologic surgery is performed for a variety of reasons including treatment of recurrent ear infections, alleviation of dizziness, and restoration of hearing loss. A typical ear surgery consists of a tympanomastoidectomy in which both the middle ear is explored via a tympanic membrane flap and the bone behind the ear is removed via mastoidectomy to treat disease and/or provide additional access. The mastoid dissection is performed using a high-speed drill to excavate bone based on a pre-operative CT scan. Intraoperatively, the surface of the mastoid component of the temporal bone provides visual feedback allowing the surgeon to guide their dissection. Dissection begins in "safe areas" which, based on surface topography, are believed to be correlated with greatest distance from surface to vital anatomy thus decreasing the chance of injury to the brain, large blood vessels (e.g. the internal jugular vein and internal carotid artery), the inner ear, and the facial nerve. "Safe areas" have been identified based on surgical experience with no identifiable studies showing correlation of the surface with subsurface anatomy. The purpose of our study was to investigate whether such a correlation exists. Through a three-step registration process, we defined a correspondence between each of twenty five clinically-applicable temporal bone CT scans of patients and an atlas and explored displacement and angular differences of surface topography and depth of critical structures from the surface of the skull. The results of this study reflect current knowledge of osteogenesis and anatomy. Based on two features (distance and angular difference), two regions (suprahelical and posterior) of the temporal bone show the least variability between surface and subsurface anatomy.

  3. Numerical analysis of ossicular chain lesion of human ear

    NASA Astrophysics Data System (ADS)

    Liu, Yingxi; Li, Sheng; Sun, Xiuzhen

    2009-04-01

    Lesion of ossicular chain is a common ear disease impairing the sense of hearing. A comprehensive numerical model of human ear can provide better understanding of sound transmission. In this study, we propose a three-dimensional finite element model of human ear that incorporates the canal, tympanic membrane, ossicular bones, middle ear suspensory ligaments/muscles, middle ear cavity and inner ear fluid. Numerical analysis is conducted and employed to predict the effects of middle ear cavity, malleus handle defect, hypoplasia of the long process of incus, and stapedial crus defect on sound transmission. The present finite element model is shown to be reasonable in predicting the ossicular mechanics of human ear.

  4. [Constricted ear therapy with free auricular composite grafts].

    PubMed

    Liu, Tun; Zhang, Lian-sheng; Zhuang, Hong-xing; Zhang, Ke-yuan

    2004-03-01

    A simple and effective therapy for single side constricted ear. Transplanting normal side free composite auricular grafts to constricted ear (15 patients and 15 sides), then lengthening the helix, exposing the scapha, correcting deformity. The 15 patients composite grafts all survived. The helix has been lengthened, the scapha exposed, the normal ear reduced, the constricted ear augmented and two sides ear have become symmetry. This method is simple and results are satisfied.

  5. Effect of Evolutionary Anisotropy on Earing Prediction in Cylindrical Cup Drawing

    NASA Astrophysics Data System (ADS)

    Choi, H. J.; Lee, K. J.; Choi, Y.; Bae, G.; Ahn, D.-C.; Lee, M.-G.

    2017-05-01

    The formability of sheet metals is associated with their planar anisotropy, and finite element simulations have been applied to the sheet metal-forming process by describing the anisotropic behaviors using yield functions and hardening models. In this study, the evaluation of anisotropic constitutive models was performed based on the non-uniform height profile or earing in circular cylindrical cup drawing. Two yield functions, a quadratic Hill1948 and a non-quadratic Yld2000-2d model, were used under non-associated and associated flow rules, respectively, to simultaneously capture directional differences in yield stress and r value. The effect of the evolution of anisotropy on the earing prediction was also investigated by employing simplified equivalent plastic strain rate-dependent anisotropic coefficients. The computational results were in good agreement with experiments when the proper choice of the yield function and flow rule, which predicts the planar anisotropy, was made. Moreover, the accuracy of the earing profile could be significantly enhanced if the evolution of anisotropy between uniaxial and biaxial stress states was additionally considered.

  6. Expression of macrophage migration inhibitory factor and CD74 in the inner ear and middle ear in lipopolysaccharide-induced otitis media.

    PubMed

    Ishihara, Hisashi; Kariya, Shin; Okano, Mitsuhiro; Zhao, Pengfei; Maeda, Yukihide; Nishizaki, Kazunori

    2016-10-01

    Significant expression of macrophage migration inhibitory factor and its receptor (CD74) was observed in both the middle ear and inner ear in experimental otitis media in mice. Modulation of macrophage migration inhibitory factor and its signaling pathway might be useful in the management of inner ear inflammation due to otitis media. Inner ear dysfunction secondary to otitis media has been reported. However, the specific mechanisms involved are not clearly understood. The aim of this study is to investigate the expression of macrophage migration inhibitory factor and CD74 in the middle ear and inner ear in lipopolysaccharide-induced otitis media. BALB/c mice received a transtympanic injection of either lipopolysaccharide or phosphate-buffered saline (PBS). The mice were sacrificed 24 h after injection, and temporal bones were processed for polymerase chain reaction (PCR) analysis, histologic examination, and immunohistochemistry. PCR examination revealed that the lipopolysaccharide-injected mice showed a significant up-regulation of macrophage migration inhibitory factor in both the middle ear and inner ear as compared with the PBS-injected control mice. The immunohistochemical study showed positive reactions for macrophage migration inhibitory factor and CD74 in infiltrating inflammatory cells, middle ear mucosa, and inner ear in the lipopolysaccharide-injected mice.

  7. Enhanced visualization of inner ear structures

    NASA Astrophysics Data System (ADS)

    Niemczyk, Kazimierz; Kucharski, Tomasz; Kujawinska, Malgorzata; Bruzgielewicz, Antoni

    2004-07-01

    Recently surgery requires extensive support from imaging technologies in order to increase effectiveness and safety of operations. One of important tasks is to enhance visualisation of quasi-phase (transparent) 3d structures. Those structures are characterized by very low contrast. It makes differentiation of tissues in field of view very difficult. For that reason the surgeon may be extremly uncertain during operation. This problem is connected with supporting operations of inner ear during which physician has to perform cuts at specific places of quasi-transparent velums. Conventionally during such operations medical doctor views the operating field through stereoscopic microscope. In the paper we propose a 3D visualisation system based on Helmet Mounted Display. Two CCD cameras placed at the output of microscope perform acquisition of stereo pairs of images. The images are processed in real-time with the goal of enhancement of quasi-phased structures. The main task is to create algorithm that is not sensitive to changes in intensity distribution. The disadvantages of existing algorithms is their lack of adaptation to occuring reflexes and shadows in field of view. The processed images from both left and right channels are overlaid on the actual images exported and displayed at LCD's of Helmet Mounted Display. A physician observes by HMD (Helmet Mounted Display) a stereoscopic operating scene with indication of the places of special interest. The authors present the hardware ,procedures applied and initial results of inner ear structure visualisation. Several problems connected with processing of stereo-pair images are discussed.

  8. Non-invasive optical assessment of viscosity of middle ear effusions in otitis media.

    PubMed

    Monroy, Guillermo L; Pande, Paritosh; Shelton, Ryan L; Nolan, Ryan M; Spillman, Darold R; Porter, Ryan G; Novak, Michael A; Boppart, Stephen A

    2017-03-01

    Eustachian tube dysfunction can cause fluid to collect within the middle ear cavity and form a middle ear effusion (MEE). MEEs can persist for weeks or months and cause hearing loss as well as speech and learning delays in young children. The ability of a physician to accurately identify and characterize the middle ear for signs of fluid and/or infection is crucial to provide the most appropriate treatment for the patient. Currently, middle ear infections are assessed with otoscopy, which provides limited and only qualitative diagnostic information. In this study, we propose a method utilizing cross-sectional depth-resolved optical coherence tomography to noninvasively measure the diffusion coefficient and viscosity of colloid suspensions, such as a MEE. Experimental validation of the proposed technique on simulated MEE phantoms with varying viscosity and particulate characteristics is presented, along with some preliminary results from in vivo and ex vivo samples of human MEEs. In vivo Optical Coherence Tomography (OCT) image of a human tympanic membrane and Middle Ear Effusion (MEE) (top), with a CCD image of the tympanic membrane surface (inset). Below is the corresponding time-lapse M-mode OCT data acquired along the white dotted line over time, which can be analyzed to determine the Stokes-Einstein diffusion coefficient of the effusion. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. A consensus-based framework for design, validation, and implementation of simulation-based training curricula in surgery.

    PubMed

    Zevin, Boris; Levy, Jeffrey S; Satava, Richard M; Grantcharov, Teodor P

    2012-10-01

    Simulation-based training can improve technical and nontechnical skills in surgery. To date, there is no consensus on the principles for design, validation, and implementation of a simulation-based surgical training curriculum. The aim of this study was to define such principles and formulate them into an interoperable framework using international expert consensus based on the Delphi method. Literature was reviewed, 4 international experts were queried, and consensus conference of national and international members of surgical societies was held to identify the items for the Delphi survey. Forty-five international experts in surgical education were invited to complete the online survey by ranking each item on a Likert scale from 1 to 5. Consensus was predefined as Cronbach's α ≥0.80. Items that 80% of experts ranked as ≥4 were included in the final framework. Twenty-four international experts with training in general surgery (n = 11), orthopaedic surgery (n = 2), obstetrics and gynecology (n = 3), urology (n = 1), plastic surgery (n = 1), pediatric surgery (n = 1), otolaryngology (n = 1), vascular surgery (n = 1), military (n = 1), and doctorate-level educators (n = 2) completed the iterative online Delphi survey. Consensus among participants was achieved after one round of the survey (Cronbach's α = 0.91). The final framework included predevelopment analysis; cognitive, psychomotor, and team-based training; curriculum validation evaluation and improvement; and maintenance of training. The Delphi methodology allowed for determination of international expert consensus on the principles for design, validation, and implementation of a simulation-based surgical training curriculum. These principles were formulated into a framework that can be used internationally across surgical specialties as a step-by-step guide for the development and validation of future simulation-based training curricula. Copyright © 2012 American College of Surgeons. Published by

  10. The comparative anatomy of the pig middle ear cavity: a model for middle ear inflammation in the human?

    PubMed Central

    PRACY, J. P.; WHITE, A.; MUSTAFA, Y.; SMITH, D.; PERRY, M. E.

    1998-01-01

    This study was undertaken to develop a functional model of otitis media with effusion (OME) in the pig (Sus scrofa), with the purpose of investigating the origin of lymphocytes populating the middle ear during the course of an inflammatory process. The relevance of the model to the human condition of OME is to a large extent dependent on the anatomical and physiological similarities between the middle ear cavity and the pharyngeal lymphoid tissue of the pig and man. Anatomical specimens were collected from 7 young Large White pigs to determine the gross anatomy of the middle ear cavity and the histological characteristics of the middle ear mucosa. It was found that the anatomy of the 3 parts of the middle ear cavity in man and in the pig is broadly similar, although some minor differences were observed. The porcine eustachian tube was seen to be cartilaginous throughout its length in contrast to the part osseous, part cartilaginous structure found in man; the porcine ossicles were slightly different in shape to those of man and the air cell system was situated inferior to the tympanic cavity in the pig as opposed to posteriorly in man. This paper describes the structure and morphology of the pig middle ear cavity and compares and contrasts it with that of man. The minor differences observed are of anatomical importance but do not diminish the usefulness of the pig middle ear cleft as a potential model for human middle ear disorders. PMID:9688502

  11. Images created in a model eye during simulated cataract surgery can be the basis for images perceived by patients during cataract surgery

    PubMed Central

    Inoue, M; Uchida, A; Shinoda, K; Taira, Y; Noda, T; Ohnuma, K; Bissen-Miyajima, H; Hirakata, A

    2014-01-01

    Purpose To evaluate the images created in a model eye during simulated cataract surgery. Patients and methods This study was conducted as a laboratory investigation and interventional case series. An artificial opaque lens, a clear intraocular lens (IOL), or an irrigation/aspiration (I/A) tip was inserted into the ‘anterior chamber' of a model eye with the frosted posterior surface corresponding to the retina. Video images were recorded of the posterior surface of the model eye from the rear during simulated cataract surgery. The video clips were shown to 20 patients before cataract surgery, and the similarity of their visual perceptions to these images was evaluated postoperatively. Results The images of the moving lens fragments and I/A tip and the insertion of the IOL were seen from the rear. The image through the opaque lens and the IOL without moving objects was the light of the surgical microscope from the rear. However, when the microscope light was turned off after IOL insertion, the images of the microscope and operating room were observed by the room illumination from the rear. Seventy percent of the patients answered that the visual perceptions of moving lens fragments were similar to the video clips and 55% reported similarity with the IOL insertion. Eighty percent of the patients recommended that patients watch the video clip before their scheduled cataract surgery. Conclusions The patients' visual perceptions during cataract surgery can be reproduced in the model eye. Watching the video images preoperatively may help relax the patients during surgery. PMID:24788007

  12. Facial Asymmetry: Brow and Ear Position.

    PubMed

    Perumal, Balaji; Meyer, Dale R

    2018-04-01

    The purpose of the current study was to analyze brow and ear position, and examine the relationship between these structures in patients presenting for blepharoplasty evaluation. A retrospective chart review was performed, which included all patients presenting to one oculoplastic physician for a blepharoplasty evaluation from November, 2012 to March, 2014. The prevalence of brow ptosis and brow and ear asymmetry was calculated; the proportional distribution was determined, and chi-square analysis and the z-test of proportions were used to calculate the significance. Institutional Review Board approval was obtained for this study. A total of 133 patients met the inclusion criteria. Some degree of brow ptosis was noted in 83% of patients. Brow asymmetry was found in 88% of patients, and ear asymmetry in 77%. Of those patients who had asymmetry, 61% had the right brow lower and 75% had the right ear lower; 73% of all patients had the brow and ear lower on the same side ( p  < 0.001). In this study, brow ptosis and asymmetry were quite common. In addition, the side of the lower brow correlated strongly with the side of the lower ear, and the right side structures were lower more often than the left. Patients presenting for blepharoplasty evaluation may have an element of generalized facial asymmetry which includes the brows and ears. These observations can be important for preoperative planning and patient counseling. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Biometric recognition using 3D ear shape.

    PubMed

    Yan, Ping; Bowyer, Kevin W

    2007-08-01

    Previous works have shown that the ear is a promising candidate for biometric identification. However, in prior work, the preprocessing of ear images has had manual steps and algorithms have not necessarily handled problems caused by hair and earrings. We present a complete system for ear biometrics, including automated segmentation of the ear in a profile view image and 3D shape matching for recognition. We evaluated this system with the largest experimental study to date in ear biometrics, achieving a rank-one recognition rate of 97.8 percent for an identification scenario and an equal error rate of 1.2 percent for a verification scenario on a database of 415 subjects and 1,386 total probes.

  14. Internet-Based Digital Simulation for Cleft Surgery Education: A 5-Year Assessment of Demographics, Usage, and Global Effect.

    PubMed

    Kantar, Rami S; Plana, Natalie M; Cutting, Court B; Diaz-Siso, Jesus Rodrigo; Flores, Roberto L

    2018-01-29

    In October 2012, a freely available, internet-based cleft simulator was created in partnership between academic, nonprofit, and industry sectors. The purpose of this educational resource was to address global disparities in cleft surgery education. This report assesses demographics, usage, and global effect of our simulator, in its fifth year since inception. Evaluate the global effect, usage, and demographics of an internet-based educational digital simulation cleft surgery software. Simulator modules, available in five languages demonstrate surgical anatomy, markings, detailed procedures, and intraoperative footage to supplement digital animation. Available data regarding number of users, sessions, countries reached, and content access were recorded. Surveys evaluating the demographic characteristics of registered users and simulator use were collected by direct e-mail. The total number of simulator new and active users reached 2865 and 4086 in June 2017, respectively. By June 2017, users from 136 countries had accessed the simulator. From 2015 to 2017, the number of sessions was 11,176 with a monthly average of 399.0 ± 190.0. Developing countries accounted for 35% of sessions and the average session duration was 9.0 ± 7.3 minutes. This yields a total simulator screen time of 100,584 minutes (1676 hours). Most survey respondents were surgeons or trainees (87%) specializing in plastic, maxillofacial, or general surgery (89%). Most users found the simulator to be useful (88%), at least equivalent or more useful than other resources (83%), and used it for teaching (58%). Our internet-based interactive cleft surgery platform reaches its intended target audience, is not restricted by socioeconomic barriers to access, and is judged to be useful by surgeons. More than 4000 active users have been reached since inception. The total screen time over approximately 2 years exceeded 1600 hours. This suggests that future surgical simulators of this kind may be sustainable by

  15. Simulation of plastic surgery and microvascular procedures using perfused fresh human cadavers.

    PubMed

    Carey, Joseph N; Rommer, Elizabeth; Sheckter, Clifford; Minneti, Michael; Talving, Peep; Wong, Alex K; Garner, Warren; Urata, Mark M

    2014-02-01

    Surgical simulation models are often limited by their lack of fidelity, which hinders their essential purpose, making a better surgeon. Fresh cadaveric tissue is a superior model of simulation owing to its approximation of live tissue. One major unresolved difference between dead and live tissue is perfusion. Here, we propose a means of enhancing the fidelity of cadaveric simulation through the development of a perfused cadaveric model whereby simulation is further able to approach life-like surgery and teach one of the more technically demanding skills of plastic surgery: microsurgery. Fresh tissue human cadavers were procured according to university protocol. Perfusion was performed via cannulation of large vessels, and arterial and venous pressure was maintained by centrifugal circulation. Skin perfusion was evaluated with incisions in the perfused regions and was evaluated using indocyanine green angiography. Surgical simulations were selected to broadly evaluate applicability to plastic surgical education. Surgical simulation of 38 procedures ranging in complexity from skin excisions to microsurgical cases was performed with high priority given to the accurate simulation of clinical procedures. Flap dissections included perforator flaps, muscle flaps, and fasciocutaneous flaps. Effective perfusion was noted with ICG angiography and notable bleeding vessels. Microsurgical flap transfer was successfully performed. We report the establishment of a high fidelity surgical simulation using a perfused fresh tissue model in a realistic environment akin to the operating room. We anticipate utilization of this model prior to entering the operating room will enhance surgical ability and offer a valuable resource in plastic surgical education. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. Acceleration induced water removal from ear canals.

    NASA Astrophysics Data System (ADS)

    Kang, Hosung; Averett, Katelee; Jung, Sunghwan

    2017-11-01

    Children and adults commonly experience having water trapped in the ear canals after swimming. To remove the water, individuals will shake their head sideways. Since a child's ear canal has a smaller diameter, it requires more acceleration of the head to remove the trapped water. In this study, we theoretically and experimentally investigated the acceleration required to break the surface meniscus of the water in artificial ear canals and hydrophobic-coated glass tubes. In experiments, ear canal models were 3D-printed from a CT-scanned human head. Also, glass tubes were coated with silane to match the hydrophobicity in ear canals. Then, using a linear stage, we measured the acceleration values required to forcefully eject the water from the artificial ear canals and glass tubes. A theoretical model was developed to predict the critical acceleration at a given tube diameter and water volume by using a modified Rayleigh-Taylor instability. Furthermore, this research can shed light on the potential of long-term brain injury and damage by shaking the head to push the water out of the ear canal. This research was supported by National Science Foundation Grant CBET-1604424.

  17. Crouzon’s Syndrome with Life-Threatening Ear Bleed: Ruptured Jugular Vein Diverticulum Treated by Endovascular Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mondel, Prabath Kumar, E-mail: prabathmondel@gmail.com; Anand, Sunanda, E-mail: sunandaanand@gmail.com; Limaye, Uday S., E-mail: uslkem@gmail.com

    Crouzon’s syndrome is the commonest variety of syndromic craniosynostosis. Life-threatening ear bleed due to ruptured jugular venous diverticulum in Crouzon’s syndrome has not been described previously. In patients with syndromic craniosynostosis, definitive repair of jugular diverticulum by open surgery is fraught with high risk of bleeding, poor functional outcomes, and even death. A 24-year-old woman with Crouzon’s syndrome presented with conductive hearing loss and recurrent episodes of torrential bleeding from her left ear. On computed tomography, a defect in the roof of jugular fossa containing jugular venous diverticulum immediately inferior to the bony external auditory canal was seen. The clinicalmore » presentation, imaging features, and endovascular management of Crouzon’s syndrome due to a ruptured jugular venous diverticulum is described.« less

  18. Radiation dose and cataract surgery incidence in atomic bomb survivors, 1986-2005.

    PubMed

    Neriishi, Kazuo; Nakashima, Eiji; Akahoshi, Masazumi; Hida, Ayumi; Grant, Eric J; Masunari, Naomi; Funamoto, Sachiyo; Minamoto, Atsushi; Fujiwara, Saeko; Shore, Roy E

    2012-10-01

    To examine the incidence of clinically important cataracts in relation to lens radiation doses between 0 and approximately 3 Gy to address risks at relatively low brief doses. Informed consent was obtained, and human subjects procedures were approved by the ethical committee at the Radiation Effects Research Foundation. Cataract surgery incidence was documented for 6066 atomic bomb survivors during 1986-2005. Sixteen risk factors for cataract, such as smoking, hypertension, and corticosteroid use, were not confounders of the radiation effect on the basis of Cox regression analysis. Radiation dose-response analyses were performed for cataract surgery incidence by using Poisson regression analysis, adjusting for demographic variables and diabetes mellitus, and results were expressed as the excess relative risk (ERR) and the excess absolute risk (EAR) (ie, measures of how much radiation multiplies [ERR] or adds to [EAR] the risk in the unexposed group). Of 6066 atomic bomb survivors, 1028 underwent a first cataract surgery during 1986-2005. The estimated threshold dose was 0.50 Gy (95% confidence interval [CI]: 0.10 Gy, 0.95 Gy) for the ERR model and 0.45 Gy (95% CI: 0.10 Gy, 1.05 Gy) for the EAR model. A linear-quadratic test for upward curvature did not show a significant quadratic effect for either the ERR or EAR model. The linear ERR model for a 70-year-old individual, exposed at age 20 years, showed a 0.32 (95% CI: 0.09, 0.53) [corrected] excess risk at 1 Gy. The ERR was highest for those who were young at exposure. These data indicate a radiation effect for vision-impairing cataracts at doses less than 1 Gy. The evidence suggests that dose standards for protection of the eye from brief radiation exposures should be 0.5 Gy or less. © RSNA, 2012.

  19. Total Face, Eyelids, Ears, Scalp, and Skeletal Subunit Transplant Research Procurement: A Translational Simulation Model.

    PubMed

    Sosin, Michael; Ceradini, Daniel J; Hazen, Alexes; Sweeney, Nicole G; Brecht, Lawrence E; Levine, Jamie P; Staffenberg, David A; Saadeh, Pierre B; Bernstein, G Leslie; Rodriguez, Eduardo D

    2016-05-01

    Cadaveric face transplant models are routinely used for technical allograft design, perfusion assessment, and transplant simulation but are associated with substantial limitations. The purpose of this study was to describe the experience of implementing a translational donor research facial procurement and solid organ allograft recovery model. Institutional review board approval was obtained, and a 49-year-old, brain-dead donor was identified for facial vascularized composite allograft research procurement. The family generously consented to donation of solid organs and the total face, eyelids, ears, scalp, and skeletal subunit allograft. The successful sequence of computed tomographic scanning, fabrication and postprocessing of patient-specific cutting guides, tracheostomy placement, preoperative fluorescent angiography, silicone mask facial impression, donor facial allograft recovery, postprocurement fluorescent angiography, and successful recovery of kidneys and liver occurred without any donor instability. Preservation of the bilateral external carotid arteries, facial arteries, occipital arteries, and bilateral thyrolinguofacial and internal jugular veins provided reliable and robust perfusion to the entirety of the allograft. Total time of facial procurement was 10 hours 57 minutes. Essential to clinical face transplant outcomes is the preparedness of the institution, multidisciplinary face transplant team, organ procurement organization, and solid organ transplant colleagues. A translational facial research procurement and solid organ recovery model serves as an educational experience to modify processes and address procedural, anatomical, and logistical concerns for institutions developing a clinical face transplantation program. This methodical approach best simulates the stressors and challenges that can be expected during clinical face transplantation. Therapeutic, V.

  20. Passage of albumin from the middle ear to the inner ear in otitis media in the chinchilla

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldberg, B.; Goycoolea, M.V.; Schleivert, P.M.

    1981-08-01

    A study of the permeability of the middle ear-inner ear interface for macromolecules was carried out in chinchillas with open and obstructed eustachian tubes utilizing tritiated human serum albumin and immunoelectrophoresis. Tritiated albumin was placed in the round window niche area or normal animals and animals in which the eustachian tubes had been obstructed for 24 hours or 14 days. The tritiated albumin was allowed to remain in the middle ear cavity for 24 hours, Samples of middle ear effusion, perilymph, blood and cerebrospinal fluid were collected and measured for radioactivity. Radioactivity was demonstrated in the perilymph. Samples of middlemore » ear effusions and perilymph were also studied by immunoelectrophoresis with goat antihuman albumin. Albumin placed in the round window niche of an experimental animal could be recovered unchanged in the perilymph. The results suggest a pathophysiologic explanation for the association of otitis media and sensorineural hearing loss or endolymphatic hydrops.« less

  1. Incorporating anthropometry into design of ear-related products.

    PubMed

    Liu, Bor-Shong

    2008-01-01

    To achieve mass customization and collaborative product design, human factors and ergonomics should play a key development role. The purpose of this study was to provide product designers with the anthropometic dimensions of outer ears for different demographic data, including gender and age. The second purpose was to compare the dimensions of various ear-related products (i.e., earphone, bluetooth earphone and ear-cup earphone) with the anthropometic database and recommend appropriate solutions for design. Two hundred subjects aged 20-59 was selected for this study and divided into four age stratifications. Further, three different dimensions of the outer ear (i.e., the earhole length, the ear connection length and the length of the pinna) were measured by superimposed grid photographic technique. The analysis of variance (ANOVA) was used to investigate the effects of gender, and age on ear dimensions. The results showed that all ear dimensions had significant gender effects. A comparison between the anthropometric dimensions and those of current products revealed that most current ear-related products need to be redesigned using anthropometric data. The shapes of earhole and pinna are not circular. Consequently, ear products need to be elongated so that users may feel more comfortably and not have the product slip off easily.

  2. Evaluation of robotic cardiac surgery simulation training: A randomized controlled trial.

    PubMed

    Valdis, Matthew; Chu, Michael W A; Schlachta, Christopher; Kiaii, Bob

    2016-06-01

    To compare the currently available simulation training modalities used to teach robotic surgery. Forty surgical trainees completed a standardized robotic 10-cm dissection of the internal thoracic artery and placed 3 sutures of a mitral valve annuloplasty in porcine models and were then randomized to a wet lab, a dry lab, a virtual reality lab, or a control group that received no additional training. All groups trained to a level of proficiency determined by 2 expert robotic cardiac surgeons. All assessments were evaluated using the Global Evaluative Assessment of Robotic Skills in a blinded fashion. Wet lab trainees showed the greatest improvement in time-based scoring and the objective scoring tool compared with the experts (mean, 24.9 ± 1.7 vs 24.9 ± 2.6; P = .704). The virtual reality lab improved their scores and met the level of proficiency set by our experts for all primary outcomes (mean, 24.9 ± 1.7 vs 22.8 ± 3.7; P = .103). Only the control group trainees were not able to meet the expert level of proficiency for both time-based scores and the objective scoring tool (mean, 24.9 ± 1.7 vs 11.0 ± 4.5; P < .001). The average duration of training was shortest for the dry lab and longest for the virtual reality simulation (1.6 hours vs 9.3 hours; P < .001). We have completed the first randomized controlled trial to objectively compare the different training modalities of robotic surgery. Our data demonstrate the significant benefits of wet lab and virtual reality robotic simulation training and highlight key differences in current training methods. This study can help guide training programs in investing resources in cost-effective, high-yield simulation exercises. Copyright © 2016 The American Association for Thoracic Surgery. All rights reserved.

  3. Benefits to Speech Perception in Noise From the Binaural Integration of Electric and Acoustic Signals in Simulated Unilateral Deafness

    PubMed Central

    Ma, Ning; Morris, Saffron; Kitterick, Pádraig Thomas

    2016-01-01

    Objectives: This study used vocoder simulations with normal-hearing (NH) listeners to (1) measure their ability to integrate speech information from an NH ear and a simulated cochlear implant (CI), and (2) investigate whether binaural integration is disrupted by a mismatch in the delivery of spectral information between the ears arising from a misalignment in the mapping of frequency to place. Design: Eight NH volunteers participated in the study and listened to sentences embedded in background noise via headphones. Stimuli presented to the left ear were unprocessed. Stimuli presented to the right ear (referred to as the CI-simulation ear) were processed using an eight-channel noise vocoder with one of the three processing strategies. An Ideal strategy simulated a frequency-to-place map across all channels that matched the delivery of spectral information between the ears. A Realistic strategy created a misalignment in the mapping of frequency to place in the CI-simulation ear where the size of the mismatch between the ears varied across channels. Finally, a Shifted strategy imposed a similar degree of misalignment in all channels, resulting in consistent mismatch between the ears across frequency. The ability to report key words in sentences was assessed under monaural and binaural listening conditions and at signal to noise ratios (SNRs) established by estimating speech-reception thresholds in each ear alone. The SNRs ensured that the monaural performance of the left ear never exceeded that of the CI-simulation ear. The advantages of binaural integration were calculated by comparing binaural performance with monaural performance using the CI-simulation ear alone. Thus, these advantages reflected the additional use of the experimentally constrained left ear and were not attributable to better-ear listening. Results: Binaural performance was as accurate as, or more accurate than, monaural performance with the CI-simulation ear alone. When both ears supported a

  4. Benefits to Speech Perception in Noise From the Binaural Integration of Electric and Acoustic Signals in Simulated Unilateral Deafness.

    PubMed

    Ma, Ning; Morris, Saffron; Kitterick, Pádraig Thomas

    2016-01-01

    This study used vocoder simulations with normal-hearing (NH) listeners to (1) measure their ability to integrate speech information from an NH ear and a simulated cochlear implant (CI), and (2) investigate whether binaural integration is disrupted by a mismatch in the delivery of spectral information between the ears arising from a misalignment in the mapping of frequency to place. Eight NH volunteers participated in the study and listened to sentences embedded in background noise via headphones. Stimuli presented to the left ear were unprocessed. Stimuli presented to the right ear (referred to as the CI-simulation ear) were processed using an eight-channel noise vocoder with one of the three processing strategies. An Ideal strategy simulated a frequency-to-place map across all channels that matched the delivery of spectral information between the ears. A Realistic strategy created a misalignment in the mapping of frequency to place in the CI-simulation ear where the size of the mismatch between the ears varied across channels. Finally, a Shifted strategy imposed a similar degree of misalignment in all channels, resulting in consistent mismatch between the ears across frequency. The ability to report key words in sentences was assessed under monaural and binaural listening conditions and at signal to noise ratios (SNRs) established by estimating speech-reception thresholds in each ear alone. The SNRs ensured that the monaural performance of the left ear never exceeded that of the CI-simulation ear. The advantages of binaural integration were calculated by comparing binaural performance with monaural performance using the CI-simulation ear alone. Thus, these advantages reflected the additional use of the experimentally constrained left ear and were not attributable to better-ear listening. Binaural performance was as accurate as, or more accurate than, monaural performance with the CI-simulation ear alone. When both ears supported a similar level of monaural

  5. Towards open-source, low-cost haptics for surgery simulation.

    PubMed

    Suwelack, Stefan; Sander, Christian; Schill, Julian; Serf, Manuel; Danz, Marcel; Asfour, Tamim; Burger, Wolfgang; Dillmann, Rüdiger; Speidel, Stefanie

    2014-01-01

    In minimally invasive surgery (MIS), virtual reality (VR) training systems have become a promising education tool. However, the adoption of these systems in research and clinical settings is still limited by the high costs of dedicated haptics hardware for MIS. In this paper, we present ongoing research towards an open-source, low-cost haptic interface for MIS simulation. We demonstrate the basic mechanical design of the device, the sensor setup as well as its software integration.

  6. Pinna abnormalities and low-set ears

    MedlinePlus

    ... Pinna abnormalities; Genetic defect - pinna; Congenital defect - pinna Images Ear abnormalities Pinna of the newborn ear References Haddad J, Keesecker S. Congenital malformations. In: Kliegman RM, Stanton BF, ...

  7. Effects of model definitions and parameter values in finite element modeling of human middle ear mechanics.

    PubMed

    De Greef, Daniel; Pires, Felipe; Dirckx, Joris J J

    2017-02-01

    Despite continuing advances in finite element software, the realistic simulation of middle ear response under acoustic stimulation continues to be challenging. One reason for this is the wide range of possible choices that can be made during the definition of a model. Therefore, an explorative study of the relative influences of some of these choices is potentially very helpful. Three finite element models of the human middle ear were constructed, based on high-resolution micro-computed tomography scans from three different human temporal bones. Interesting variations in modeling definitions and parameter values were selected and their influences on middle ear transmission were evaluated. The models were compared against different experimental validation criteria, both from the literature and from our own measurements. Simulation conditions were restricted to the frequency range 0.1-10 kHz. Modeling the three geometries with the same modeling definitions and parameters produces stapes footplate response curves that exhibit similar shapes, but quantitative differences of 4 dB in the lower frequencies and up to 6 dB around the resonance peaks. The model properties with the largest influences on our model outcomes are the tympanic membrane (TM) damping and stiffness and the cochlear load. Model changes with a small to negligible influence include the isotropy or orthotropy of the TM, the geometry of the connection between the TM and the malleus, the microstructure of the incudostapedial joint, and the length of the tensor tympani tendon. The presented results provide insights into the importance of different features in middle ear finite element modeling. The application of three different individual middle ear geometries in a single study reduces the possibility that the conclusions are strongly affected by geometrical abnormalities. Some modeling variations that were hypothesized to be influential turned out to be of minor importance. Furthermore, it could be

  8. Endoscopic sinus surgery dissection courses using a real simulator: the benefits of this training.

    PubMed

    Fortes, Bibiana; Balsalobre, Leonardo; Weber, Raimar; Stamm, Raquel; Stamm, Aldo; Oto, Fernando; Coronel, Nathália

    2016-01-01

    Endonasal surgeries are among the most common procedures performed in otolaryngology. Due to difficulty in cadaver acquisition and the intrinsic risks of training residents during operations on real patients, nasosinusal endoscopic dissection courses utilizing real simulators, such as the Sinus Model Otorhino Neuro Trainer are being developed as a new technique to facilitate the acquisition of better anatomical knowledge and surgical skill. To evaluate the efficacy of nasosinusal endoscopic dissection courses with the Sinus Model Otorhino Neuro Trainer simulator in the training of otolaryngology surgeons. A prospective, longitudinal cohort study was conducted with 111 otolaryngologists who participated in a theoretical and practical course of endoscopic surgery dissection using the Sinus Model Otorhino Neuro Trainer simulator, with application of questionnaires during and after the course. From the ten procedures performed utilizing the simulator, the evaluation revealed mean scores from 3.1 to 4.1 (maximum of 5). Seventy-seven participants answered the questionnaire six months after the end of the course. 93% of them reported that they could perform the procedures more safely following the course, 98% reported an improvement in their anatomical and clinical knowledge, and 85% related an improvement in their surgical ability. After the course, the number of endoscopic surgeries increased in 40% of the respondents. Endoscopic sinus dissection courses using the Sinus Model Otorhino Neuro Trainer simulator proved to be useful in the training of otolaryngologists. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  9. Single-stage autologous ear reconstruction for microtia.

    PubMed

    Kasrai, Leila; Snyder-Warwick, Alison K; Fisher, David M

    2014-03-01

    The authors have been using the Nagata technique since 2002. In this review of 100 consecutive ear reconstructions, the authors present technique modifications that have evolved over this period that have contributed to improved auricular contour and that now allow for auricular reconstruction in a single stage. This study is a retrospective review of a prospectively acquired database. The series is restricted to primary reconstructions performed for congenital microtia. Photographs of 10 consecutive patients are presented to demonstrate the results of the technique. Surgical complication rates are discussed. One hundred ear reconstructions were performed in 96 patients. There were 75 primary cases of congenital microtia. Twenty-four ears underwent a two-stage reconstruction, and 51 ears were reconstructed with a Nagata stage I procedure or a single-stage reconstruction. There was a gradual shift in technique, with a trend to perform fewer Nagata stage II outsetting procedures and more single-stage reconstructions. In patients who underwent an ear reconstruction in two stages, the surgical complication rate was 22 percent. In the last 40 consecutive ear reconstructions since abandoning the two-stage approach, the surgical complication rate is now 15 percent. A modification of Nagata's technique of autologous ear reconstruction for microtia is described. Modifications of the three-dimensional framework address the contour of the inferior crus and control tragal projection and position. Inclusion of a projection block and recruitment of retroauricular skin allow for symmetric projection of the ear in a single stage. Therapeutic, IV.

  10. Audiometric Predictions Using SFOAE and Middle-Ear Measurements

    PubMed Central

    Ellison, John C.; Keefe, Douglas H.

    2006-01-01

    Objective The goals of the study are to determine how well stimulus-frequency otoacoustic emissions (SFOAEs) identify hearing loss, classify hearing loss as mild or moderate-severe, and correlate with pure-tone thresholds in a population of adults with normal middle-ear function. Other goals are to determine if middle-ear function as assessed by wideband acoustic transfer function (ATF) measurements in the ear canal account for the variability in normal thresholds, and if the inclusion of ATFs improves the ability of SFOAEs to identify hearing loss and predict pure-tone thresholds. Design The total suppressed SFOAE signal and its corresponding noise were recorded in 85 ears (22 normal ears and 63 ears with sensorineural hearing loss) at octave frequencies from 0.5 – 8 kHz using a nonlinear residual method. SFOAEs were recorded a second time in three impaired ears to assess repeatability. Ambient-pressure ATFs were obtained in all but one of these 85 ears, and were also obtained from an additional 31 normal-hearing subjects in whom SFOAE data were not obtained. Pure-tone air-and bone-conduction thresholds and 226-Hz tympanograms were obtained on all subjects. Normal tympanometry and the absence of air-bone gaps were used to screen subjects for normal middle-ear function. Clinical decision theory was used to assess the performance of SFOAE and ATF predictors in classifying ears as normal or impaired, and linear regression analysis was used to test the ability of SFOAE and ATF variables to predict the air-conduction audiogram. Results The ability of SFOAEs to classify ears as normal or hearing impaired was significant at all test frequencies. The ability of SFOAEs to classify impaired ears as either mild or moderate-severe was significant at test frequencies from 0.5 to 4 kHz. SFOAEs were present in cases of severe hearing loss. SFOAEs were also significantly correlated with air-conduction thresholds from 0.5 to 8 kHz. The best performance occurred using the SFOAE

  11. Residents' response to bleeding during a simulated robotic surgery task.

    PubMed

    Walker, Jessica L; Nathwani, Jay N; Mohamadipanah, Hossein; Laufer, Shlomi; Jocewicz, Frank F; Gwillim, Eran; Pugh, Carla M

    2017-12-01

    The aim of this study was to assess performance measurement validity of our newly developed robotic surgery task trainer. We hypothesized that residents would exhibit wide variations in their intercohort performance as well as a measurable difference compared to surgeons in fellowship training. Our laboratory synthesized a model of a pelvic tumor that simulates unexpected bleeding. Surgical residents and fellows of varying specialties completed a demographic survey and were allowed 20 minutes to resect the tumor using the da Vinci robot and achieve hemostasis. At a standardized event in the simulation, venous bleeding began, and participants attempted hemostasis using suture ligation. A motion tracking system, using electromagnetic sensors, recorded participants' hand movements. A postparticipation Likert scale survey evaluated participants' assessment of the model's realism and usefulness. Three of the seven residents (postgraduate year 2-5), and the fellow successfully resected the tumor in the allotted time. Residents showed high variability in performance and blood loss (125-700 mL) both within their cohort and compared to the fellow (150 mL blood). All participants rated the model as having high realism and utility for trainees. The results support that our bleeding pelvic tumor simulator has the ability to discriminate resident performance in robotic surgery. The combination of motion, decision-making, and blood loss metrics offers a multilevel performance assessment, analyzing both technical and decision-making abilities. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. An Effective 3D Ear Acquisition System

    PubMed Central

    Liu, Yahui; Lu, Guangming; Zhang, David

    2015-01-01

    The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. It can be easily captured from a distance without a fully cooperative subject. Also, the ear has a relatively stable structure that does not change much with the age and facial expressions. In this paper, we present a novel method of 3D ear acquisition system by using triangulation imaging principle, and the experiment results show that this design is efficient and can be used for ear recognition. PMID:26061553

  13. An Effective 3D Ear Acquisition System.

    PubMed

    Liu, Yahui; Lu, Guangming; Zhang, David

    2015-01-01

    The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. It can be easily captured from a distance without a fully cooperative subject. Also, the ear has a relatively stable structure that does not change much with the age and facial expressions. In this paper, we present a novel method of 3D ear acquisition system by using triangulation imaging principle, and the experiment results show that this design is efficient and can be used for ear recognition.

  14. Animal models of middle ear cholesteatoma.

    PubMed

    Yamamoto-Fukuda, Tomomi; Takahashi, Haruo; Koji, Takehiko

    2011-01-01

    Middle ear acquired cholesteatoma is a pathological condition associated with otitis media, which may be associated with temporal bone resorption, otorrhea and hearing loss, and occasionally various other complications. Cholesteatoma is characterized by the enhanced proliferation of epithelial cells with aberrant morphologic characteristics. Unfortunately, our understanding of the mechanism underlying its pathogenesis is limited. To investigate its pathogenesis, different animal models have been used. This paper provides a brief overview of the current status of research in the field of pathogenesis of middle ear acquired cholesteatoma, four types of animal models previously reported on, up-to-date cholesteatoma research using these animal models, our current studies of the local hybrid ear model, and the future prospect of new animal models of middle ear cholesteatoma.

  15. Animal Models of Middle Ear Cholesteatoma

    PubMed Central

    Yamamoto-Fukuda, Tomomi; Takahashi, Haruo; Koji, Takehiko

    2011-01-01

    Middle ear acquired cholesteatoma is a pathological condition associated with otitis media, which may be associated with temporal bone resorption, otorrhea and hearing loss, and occasionally various other complications. Cholesteatoma is characterized by the enhanced proliferation of epithelial cells with aberrant morphologic characteristics. Unfortunately, our understanding of the mechanism underlying its pathogenesis is limited. To investigate its pathogenesis, different animal models have been used. This paper provides a brief overview of the current status of research in the field of pathogenesis of middle ear acquired cholesteatoma, four types of animal models previously reported on, up-to-date cholesteatoma research using these animal models, our current studies of the local hybrid ear model, and the future prospect of new animal models of middle ear cholesteatoma. PMID:21541229

  16. Ear keloids as a primary candidate for the application of mitomycin C after shave excision: in vivo and in vitro study.

    PubMed

    Chi, Seong Geun; Kim, Jun Young; Lee, Weon Ju; Lee, Seok-Jong; Kim, Do Won; Sohn, Mi Yeung; Kim, Gun Wook; Kim, Moon Bum; Kim, Byung Soo

    2011-02-01

    Although many methods have been developed to treat ear keloids, new therapeutic options are still needed. To determine the effects of topical mitomycin C (MC) on shave-removed wounds and fibroblasts of ear keloids. Fourteen ear keloids in 12 patients were shaved, and MC (1 mg/mL) was applied to the resected bed for 5 minutes. The application was repeated 3 weeks later. All patients were assessed 2, 4, and 6 months after the procedure to evaluate the cosmetic results, recurrence, and postsurgical complications. An in vitro study to determine the effects of MC on fibroblasts of the excised keloids was conducted using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, the measurement of total cell counts, and immunoassay of DNA synthesis. Only one recurrence occurred (on the ear helix), and the patients were satisfied with the cosmetic outcomes. The results of the MTT assay, total cell counts, and DNA synthesis immunoassay confirmed the suppressive effects of MC on the keloid fibroblasts. The application of topical MC to the resected bed of shave-removed ear keloids was successful in preventing recurrences and providing an acceptable cosmetic outcome. © 2011 by the American Society for Dermatologic Surgery, Inc.

  17. What is going on in augmented reality simulation in laparoscopic surgery?

    PubMed

    Botden, Sanne M B I; Jakimowicz, Jack J

    2009-08-01

    To prevent unnecessary errors and adverse results of laparoscopic surgery, proper training is of paramount importance. A safe way to train surgeons for laparoscopic skills is simulation. For this purpose traditional box trainers are often used, however they lack objective assessment of performance. Virtual reality laparoscopic simulators assess performance, but lack realistic haptic feedback. Augmented reality (AR) combines a virtual reality (VR) setting with real physical materials, instruments, and feedback. This article presents the current developments in augmented reality laparoscopic simulation. Pubmed searches were performed to identify articles regarding surgical simulation and augmented reality. Identified companies manufacturing an AR laparoscopic simulator received the same questionnaire referring to the features of the simulator. Seven simulators that fitted the definition of augmented reality were identified during the literature search. Five of the approached manufacturers returned a completed questionnaire, of which one simulator appeared to be VR and was therefore not applicable for this review. Several augmented reality simulators have been developed over the past few years and they are improving rapidly. We recommend the development of AR laparoscopic simulators for component tasks of procedural training. AR simulators should be implemented in current laparoscopic training curricula, in particular for laparoscopic suturing training.

  18. Ear Infection in Isolated Cleft Lip: Etiological Implications

    PubMed Central

    Ruegg, Teresa A.; Cooper, Margaret E.; Leslie, Elizabeth J.; Ford, Matthew D.; Wehby, George L.; Deleyiannis, Frederic W.B.; Czeizel, Andrew E.; Hecht, Jacqueline T.; Marazita, Mary L.; Weinberg, Seth M.

    2015-01-01

    Background and Hypothesis Chronic ear infections are a common occurrence in children with orofacial clefts involving the secondary palate. Less is known about the middle ear status of individuals with isolated clefts of the lip, although several studies have reported elevated rates of ear infection in this group. The purpose of this retrospective study was to test the hypothesis that chronic ear infections occur more frequently in isolated cleft lip cases (n=94) compared with controls (n=183). Methods A questionnaire was used to obtain information on history of chronic ear infection. The association between ear infection status (present/absent) and cleft lip status (cleft lip case/control) was tested using both chi-square and logistic regression. Results and Conclusions The reported occurrence of chronic ear infection was significantly greater in cleft lipcases (31%) compared to unaffected controls (11%). After adjusting for age and sex, having a cleft lip increased the odds of being positive for ear infection by a factor greater than three (OR=3.698; 95%CI=1.91–7.14). Within cleft lipcases, there was no difference in the occurrence of ear infection by defect laterality or by the type of clefting present in the family history. Although velopharyngeal insufficiency was present in 18.4% of our cleft lip sample, there was no statistical association between ear infection and abnormal speech patterns. These results may have potential implications both for the clinical management of isolated cleft lip cases and for understanding the etiology of orofacial clefting. PMID:26153759

  19. Ear Infection in Isolated Cleft Lip: Etiological Implications.

    PubMed

    Ruegg, Teresa A; Cooper, Margaret E; Leslie, Elizabeth J; Ford, Matthew D; Wehby, George L; Deleyiannis, Frederic W B; Czeizel, Andrew E; Hecht, Jacqueline T; Marazita, Mary L; Weinberg, Seth M

    2017-03-01

      Chronic ear infections are a common occurrence in children with orofacial clefts involving the secondary palate. Less is known about the middle ear status of individuals with isolated clefts of the lip, although several studies have reported elevated rates of ear infection in this group. The purpose of this retrospective study was to test the hypothesis that chronic ear infections occur more frequently in isolated cleft lip cases (n = 94) compared with controls (n = 183).   A questionnaire was used to obtain information on history of chronic ear infection. The association between ear infection status (present/absent) and cleft lip status (cleft lip case/control) was tested using both chi-square and logistic regression.   The reported occurrence of chronic ear infection was significantly greater in cleft lip cases (31%) compared with unaffected controls (11%). After adjusting for age and sex, having a cleft lip increased the odds of being positive for ear infection by a factor greater than 3 (odds ratio = 3.698; 95% confidence interval = 1.91 to 7.14). Within cleft lip cases, there was no difference in the occurrence of ear infection by defect laterality or by the type of clefting present in the family history. Although velopharyngeal insufficiency was present in 18.4% of our cleft lip sample, there was no statistical association between ear infection and abnormal speech patterns. These results may have potential implications both for the clinical management of isolated cleft lip cases and for understanding the etiology of orofacial clefting.

  20. Ear tag

    MedlinePlus

    ... an ear tag or pit are: An inherited tendency to have this facial feature A genetic syndrome ... Elsevier Churchill Livingstone; 2016:chap 19. Review Date 4/24/2017 Updated by: Liora C Adler, MD, ...

  1. Ear Infections

    MedlinePlus

    ... but they are less common. The infection usually affects the middle ear and is called otitis media. ... become clogged with fluid and mucus. This can affect hearing, because sound cannot get through all that ...

  2. Ear emergencies

    MedlinePlus

    ... and ruptured eardrums can be caused by: Inserting cotton swabs, toothpicks, pins, pens, or other objects into ... The person will have severe pain. Place sterile cotton gently in the outer ear canal to keep ...

  3. Effects of middle ear quasi-static stiffness on sound transmission quantified by a novel 3-axis optical force sensor.

    PubMed

    Dobrev, Ivo; Sim, Jae Hoon; Aqtashi, Baktash; Huber, Alexander M; Linder, Thomas; Röösli, Christof

    2018-01-01

    Intra-operative quantification of the ossicle mobility could provide valuable feedback for the current status of the patient's conductive hearing. However, current methods for evaluation of middle ear mobility are mostly limited to the surgeon's subjective impression through manual palpation of the ossicles. This study investigates how middle ear transfer function is affected by stapes quasi-static stiffness of the ossicular chain. The stiffness of the middle ear is induced by a) using a novel fiber-optic 3-axis force sensor to quantify the quasi-static stiffness of the middle ear, and b) by artificial reduction of stapes mobility due to drying of the middle ear. Middle ear transfer function, defined as the ratio of the stapes footplate velocity versus the ear canal sound pressure, was measured with a single point LDV in two conditions. First, a controlled palpation force was applied at the stapes head in two in-plane (superior-inferior or posterior-anterior) directions, and at the incus lenticular process near the incudostapedial joint in the piston (lateral-medial) direction with a novel 3-axis PalpEar force sensor (Sensoptic, Losone, Switzerland), while the corresponding quasi-static displacement of the contact point was measured via a 3-axis micrometer stage. The palpation force was applied sequentially, step-wise in the range of 0.1-20 gF (1-200 mN). Second, measurements were repeated with various stages of stapes fixation, simulated by pre-load on the stapes head or drying of the temporal bone, and with severe ossicle immobilization, simulated by gluing of the stapes footplate. Simulated stapes fixation (forced drying of 5-15 min) severely decreases (20-30 dB) the low frequency (<1 kHz) response of the middle ear, while increasing (5-10 dB) the high frequency (>4 kHz) response. Stapes immobilization (gluing of the footplate) severely reduces (20-40 dB) the low and mid frequency response (<4 kHz) but has lesser effect (<10 dB) at higher frequencies

  4. Management of auricular hematoma and the cauliflower ear.

    PubMed

    Greywoode, Jewel D; Pribitkin, Edmund A; Krein, Howard

    2010-12-01

    Acute auricular hematoma is common after blunt trauma to the side of the head. A network of vessels provides a rich blood supply to the ear, and the ear cartilage receives its nutrients from the overlying perichondrium. Prompt management of hematoma includes drainage and prevention of reaccumulation. If left untreated, an auricular hematoma can result in complications such as perichondritis, infection, and necrosis. Cauliflower ear may result from long-standing loss of blood supply to the ear cartilage and formation of neocartilage from disrupted perichondrium. Management of cauliflower ear involves excision of deformed cartilage and reshaping of the auricle. © Thieme Medical Publishers.

  5. A simulator for surgery training: optimal sensory stimuli in a bone pinning simulation

    NASA Astrophysics Data System (ADS)

    Daenzer, Stefan; Fritzsche, Klaus

    2008-03-01

    Currently available low cost haptic devices allow inexpensive surgical training with no risk to patients. Major drawbacks of lower cost devices include limited maximum feedback force and the incapability to expose occurring moments. Aim of this work was the design and implementation of a surgical simulator that allows the evaluation of multi-sensory stimuli in order to overcome the occurring drawbacks. The simulator was built following a modular architecture to allow flexible combinations and thorough evaluation of different multi-sensory feedback modules. A Kirschner-Wire (K-Wire) tibial fracture fixation procedure was defined and implemented as a first test scenario. A set of computational metrics has been derived from the clinical requirements of the task to objectively assess the trainees performance during simulation. Sensory feedback modules for haptic and visual feedback have been developed, each in a basic and additionally in an enhanced form. First tests have shown that specific visual concepts can overcome some of the drawbacks coming along with low cost haptic devices. The simulator, the metrics and the surgery scenario together represent an important step towards a better understanding of the perception of multi-sensory feedback in complex surgical training tasks. Field studies on top of the architecture can open the way to risk-less and inexpensive surgical simulations that can keep up with traditional surgical training.

  6. Effects of Varieties, Producing Areas, Ears, and Ear Positions of Single Maize Kernels on Near-Infrared Spectra for Identification and Traceability.

    PubMed

    An, Dong; Cui, Yongjin; Liu, Xu; Jia, Shiqiang; Zheng, Shuyun; Che, Xiaoping; Liu, Zhe; Zhang, Xiaodong; Zhu, Dehai; Li, Shaoming

    2016-01-01

    The effects of varieties, producing areas, ears, and ear positions of maize on near-infrared (NIR) spectra were investigated to determine the factors causing the differences in NIR fingerprints of maize varieties. A total of 130 inbred lines were grown in two regions in China, and 12,350 kernel samples were analyzed through NIR spectroscopy. Spectral differences among varieties, producing areas, ears, and ear positions were determined and compared on the basis of pretreated spectra. The bands at 1300-1470, 1768-1949, 2010-2064, and 2235-2311 nm were mainly affected by the producing area. Band selection and principal component analysis were applied to improve the influence of variety on NIR spectra by processing the pretreated spectra. The degrees of the influence of varieties, producing areas, ears, and ear positions were calculated, and the percentages of the influence of varieties, producing areas, ears, and ear positions were 45.40%, 42.66%, 8.22%, and 3.72%, respectively. Therefore, genetic differences among maize inbred lines are the main factors accounted for NIR spectral differences. Producing area is a secondary factor. These results could provide a reference for researchers who authenticate varieties, perform geographical origin traceabilities, and conduct maize seed breeding.

  7. A review of computer-aided oral and maxillofacial surgery: planning, simulation and navigation.

    PubMed

    Chen, Xiaojun; Xu, Lu; Sun, Yi; Politis, Constantinus

    2016-11-01

    Currently, oral and maxillofacial surgery (OMFS) still poses a significant challenge for surgeons due to the anatomic complexity and limited field of view of the oral cavity. With the great development of computer technologies, he computer-aided surgery has been widely used for minimizing the risks and improving the precision of surgery. Areas covered: The major goal of this paper is to provide a comprehensive reference source of current and future development of computer-aided OMFS including surgical planning, simulation and navigation for relevant researchers. Expert commentary: Compared with the traditional OMFS, computer-aided OMFS overcomes the disadvantage that the treatment on the region of anatomically complex maxillofacial depends almost exclusively on the experience of the surgeon.

  8. Innovations in surgery simulation: a review of past, current and future techniques

    PubMed Central

    Burtt, Karen; Solorzano, Carlos A.; Carey, Joseph N.

    2016-01-01

    As a result of recent work-hours limitations and concerns for patient safety, innovations in extraclinical surgical simulation have become a desired part of residency education. Current simulation models, including cadaveric, animal, bench-top, virtual reality (VR) and robotic simulators are increasingly used in surgical training programs. Advances in telesurgery, three-dimensional (3D) printing, and the incorporation of patient-specific anatomy are paving the way for simulators to become integral components of medical training in the future. Evidence from the literature highlights the benefits of including simulations in surgical training; skills acquired through simulations translate into improvements in operating room performance. Moreover, simulations are rapidly incorporating new medical technologies and offer increasingly high-fidelity recreations of procedures. As a result, both novice and expert surgeons are able to benefit from their use. As dedicated, structured curricula are developed that incorporate simulations into daily resident training, simulated surgeries will strengthen the surgeon’s skill set, decrease hospital costs, and improve patient outcomes. PMID:28090509

  9. Innovations in surgery simulation: a review of past, current and future techniques.

    PubMed

    Badash, Ido; Burtt, Karen; Solorzano, Carlos A; Carey, Joseph N

    2016-12-01

    As a result of recent work-hours limitations and concerns for patient safety, innovations in extraclinical surgical simulation have become a desired part of residency education. Current simulation models, including cadaveric, animal, bench-top, virtual reality (VR) and robotic simulators are increasingly used in surgical training programs. Advances in telesurgery, three-dimensional (3D) printing, and the incorporation of patient-specific anatomy are paving the way for simulators to become integral components of medical training in the future. Evidence from the literature highlights the benefits of including simulations in surgical training; skills acquired through simulations translate into improvements in operating room performance. Moreover, simulations are rapidly incorporating new medical technologies and offer increasingly high-fidelity recreations of procedures. As a result, both novice and expert surgeons are able to benefit from their use. As dedicated, structured curricula are developed that incorporate simulations into daily resident training, simulated surgeries will strengthen the surgeon's skill set, decrease hospital costs, and improve patient outcomes.

  10. Pierced Ears

    MedlinePlus

    ... weeks. Then you can start enjoying your pierced ears again! Reviewed by: Steven Dowshen, MD Date reviewed: September ... All information on KidsHealth® is for educational purposes only. For specific medical advice, diagnoses, and treatment, ...

  11. Fumonisin B(1)-nonproducing strains of Fusarium verticillioides cause maize (Zea mays) ear infection and ear rot.

    PubMed

    Desjardins, A E; Plattner, R D

    2000-11-01

    Fumonisins are polyketide mycotoxins produced by Fusarium verticillioides (synonym F. moniliforme), a major pathogen of maize (Zea mays) worldwide. Most field strains produce high levels of fumonisin B(1) (FB(1)) and low levels of the less-oxygenated homologues FB(2) and FB(3), but fumonisin B(1)-nonproducing field strains have been obtained by natural variation. To test the role of various fumonisins in pathogenesis on maize under field conditions, one strain producing FB(1), FB(2), and FB(3), one strain producing only FB(2), one strain producing only FB(3), and one fumonisin-nonproducing strain were applied to ears via the silk channel and on seeds at planting. Disease severity on the harvested ears was evaluated by visible symptoms and by weight percent symptomatic kernels. Fumonisin levels in kernels were determined by high-performance liquid chromatography. The presence of the applied FB(1)-nonproducing strains in kernels was determined by analysis of recovered strains for fumonisin production and other traits. All three FB(1)-nonproducing strains were able to infect ears following either silk-channel application or seed application at planting and were as effective as the FB(1)-producing strain in causing ear rot following silk-channel application. These results indicate that production of FB(1), FB(2), or FB(3) is not required for F. verticillioides to cause maize ear infection and ear rot.

  12. Insights into inner ear-specific gene regulation: epigenetics and non-coding RNAs in inner ear development and regeneration

    PubMed Central

    Avraham, Karen B.

    2016-01-01

    The vertebrate inner ear houses highly specialized sensory organs, tuned to detect and encode sound, head motion and gravity. Gene expression programs under the control of transcription factors orchestrate the formation and specialization of the non-sensory inner ear labyrinth and its sensory constituents. More recently, epigenetic factors and non-coding RNAs emerged as an additional layer of gene regulation, both in inner ear development and disease. In this review, we provide an overview on how epigenetic modifications and non-coding RNAs, in particular microRNAs (miRNAs), influence gene expression and summarize recent discoveries that highlight their critical role in the proper formation of the inner ear labyrinth and its sensory organs. In contrast to non-mammalian vertebrates, adult mammals lack the ability to regenerate inner ear mechano-sensory hair cells. Finally, we discuss recent insights into how epigenetic factors and miRNAs may facilitate, or in the case of mammals, restrict sensory hair cell regeneration. PMID:27836639

  13. A novel simulation model for minimally invasive spine surgery.

    PubMed

    Walker, James B; Perkins, Eddie; Harkey, H Louis

    2009-12-01

    Minimally invasive spine surgery (MISS) is among the fastest growing technologies in general neurosurgical practice. In addition, great demand exists to teach these skills to neurosurgery residents. With newly enforced work hour restrictions, opportunities to acquire these skills are limited, necessitating development of alternative strategies of education. We describe a novel simulation model for MISS supplemented by resident self-assessment analysis and evaluation. The simulator was constructed using a nontransparent Plexiglas frame supplemented with a modified halo frame on which to affix spine specimens. Interchangeable copper tubing was affixed to a 360-degree pivot system to replicate a working portal. Deer skulls and spines were then collected and prepared accordingly. Laboratory exercises were based on the resident's level of training with emphasis on proper drilling techniques. Eight neurosurgery residents were asked to complete the exercises and complete a self-assessment survey regarding their competence level on a scale of 0 to 5, both before and after completing the skill sets. Additionally, they were asked to complete an exit survey that was used to assess the simulation exercises. All exercises were completed successfully with the exception of placing 2 separate pedicle screws through the same portal, which posed difficulty on some specimens because of the of lack of lordosis of the specimens, leading to unfavorable trajectories using a free-hand technique. With regard to the resident self-assessment analysis, the mean confidence rating for performing an MISS laminectomy improved by a difference of 1.25 points (n = 8; 95% confidence interval, 0.66-1.84; P = 0.0015), from 2.50 to 3.75 before and after simulation exercises, respectively, and reached statistical significance. For the senior-level residents, the mean confidence rating for performing MISS placement of pedicle screws using a free-hand technique improved by a difference of 1.00 (n = 3; 95

  14. Musical ear syndrome in adult cochlear implant patients.

    PubMed

    Low, W-K; Tham, C A; D'Souza, V-D; Teng, S-W

    2013-09-01

    Except for a single case report, musical ear syndrome in cochlear implantees has not been studied. We aimed to study the prevalence and nature of musical ear syndrome among adult cochlear implant patients, as well as the effect on their emotional well-being. STUDY DESIGN, PATIENTS AND INTERVENTION: A cross-sectional survey of patients aged 18 years and above who had received cochlear implants for profound hearing loss between 1997 and 2010. Of the 82 patients studied, 18 (22 per cent) were found to have experienced musical ear syndrome. Seven and 11 patients had musical ear syndrome prior to and after cochlear implantation, respectively. The character of musical ear syndrome symptoms was described as instrumental music (n = 2), singing (6) or both (10). Fourteen patients reported an adverse emotional effect, with three expressing ‘intolerance’. In this study, 22 per cent of cochlear implantees experienced musical ear syndrome. These symptoms affected patients’ emotional state, but most coped well. Musical ear syndrome can occur prior to and after cochlear implantation.

  15. [Adaptability of sweet corn ears to a frozen process].

    PubMed

    Ramírez Matheus, Alejandra O; Martínez, Norelkys Maribel; de Bertorelli, Ligia O; De Venanzi, Frank

    2004-12-01

    The effects of frozen condition on the quality of three sweet corn ears (2038, 2010, 2004) and the pattern (Bonanza), were evaluated. Biometrics characteristics like ear size, ear diameter, row and kernel deep were measured as well as chemical and physical measurement in fresh and frozen states. The corn ears were frozen at -95 degrees C by 7 minutes. The yield and stability of the frozen ears were evaluated at 45 and 90 days of frozen storage (-18 degrees C). The average commercial yield as frozen corn ear for all the hybrids was 54.2%. The industry has a similar value range of 48% to 54%. The ear size average was 21.57 cm, row number was 15, ear diameter 45.54 mm and the kernel corn deep was 8.57 mm. All these measurements were found not different from commercial values found for the industry. All corn samples evaluated showed good stability despites the frozen processing and storage. Hybrid 2038 ranked higher in quality.

  16. Relationship Between Audio-Vestibular Functional Tests and Inner Ear MRI in Meniere's Disease.

    PubMed

    Quatre, Raphaële; Attyé, Arnaud; Karkas, Alexandre; Job, Agnès; Dumas, Georges; Schmerber, Sébastien

    2018-04-25

    Meniere's disease is an inner ear disorder generally attributed to an endolymphatic hydrops. Different electrophysiological tests and imaging techniques have been developed to improve endolymphatic hydrops diagnosis. The goal of our study was to compare the sensitivity and the specificity of delayed inner ear magnetic resonance imaging (MRI) after intravenous injection of gadolinium with extratympanic clicks electrocochleography (EcochG), phase shift of distortion product otoacoustic emissions (shift-DPOAEs), and cervical vestibular-evoked myogenic potentials (cVEMP) for the diagnosis of Meniere's disease. Forty-one patients, with a total of 50 affected ears, were included prospectively from April 2015 to April 2016 in our institution. Patients included had definite or possible Meniere's disease based on the latest American Academy of Otolaryngology-Head and Neck Surgery guidelines revised in 2015. All patients went through delayed inner ear MRI after intravenous injection of gadolinium (three dimension-fluid attenuated inversion recovery sequences), pure-tone audiometry, extratympanic clicks EcochG, shift-DPOAEs, and cVEMP on the same day. Endolymphatic hydrops was graded on MRI using the saccule to utricle ratio inversion defined as when the saccule appeared equal or larger than the utricle. Abnormal EcochG and shift-DPOAEs in patients with definite Meniere's disease (DMD) were found in 68 and 64.5%, respectively. The two methods were significantly associated in DMD group. In DMD group, 25.7% had a positive MRI. The correlation between MRI versus EcochG and MRI versus shift-DPOAEs was not significant. MRI hydrops detection was correlated with hearing loss. Finally, 22.9% of DMD group had positive cVEMP. EcochG and shift-DPOAEs were both well correlated with clinical criteria of Meniere's disease. Inner ear MRI showed hydrops when hearing loss was higher than 35 dB. The shift-DPOAEs presented the advantage of a rapid and easy measurement if DPOAEs could be

  17. Distortion product otoacoustic emissions upon ear canal pressurization.

    PubMed

    Zebian, Makram; Schirkonyer, Volker; Hensel, Johannes; Vollbort, Sven; Fedtke, Thomas; Janssen, Thomas

    2013-04-01

    The purpose of this study was to quantify the change in distortion product otoacoustic emission (DPOAE) level upon ear canal pressurization. DPOAEs were measured on 12 normal-hearing human subjects for ear canal static pressures between -200 and +200 daPa in (50 ± 5) daPa steps. A clear dependence of DPOAE levels on the pressure was observed, with levels being highest at the maximum compliance of the middle ear, and decreasing on average by 2.3 dB per 50 daPa for lower and higher pressures. Ear canal pressurization can serve as a tool for improving the detectability of DPOAEs in the case of middle-ear dysfunction.

  18. Big Stimulus, Little Ears: Safety in Administering Vestibular Evoked Myogenic Potentials (VEMP) in Children

    PubMed Central

    Thomas, Megan L.A.; Fitzpatrick, Denis; McCreery, Ryan; Janky, Kristen L.

    2017-01-01

    Background Cervical and ocular Vestibular Evoked Myogenic Potentials (VEMPs) have become common clinical vestibular assessments. However, VEMP testing requires high intensity stimuli, raising concerns regarding safety with children, where sound pressure levels may be higher due to their smaller ear canal volumes. Purpose The purpose of this study was to estimate the range of peak-to-peak equivalent sound pressure levels (peSPLs) in child and adult ears in response to high intensity stimuli (i.e., 100 dB normal hearing level (nHL)) commonly used for VEMP testing and make a determination of whether acoustic stimuli levels with VEMP testing are safe for use in children. Research Design Prospective Experimental. Study Sample Ten children (4–6 years) and ten young adults (24 – 35 years) with normal hearing sensitivity and middle ear function participated in the study. Data Collection and Analysis Probe microphone peSPL measurements of clicks and 500 Hz tonebursts (TBs) were recorded in tubes of small, medium, and large diameter, and in a Brüel & Kjær Ear Simulator Type 4157 to assess for linearity of the stimulus at high levels. The different diameter tubes were used to approximate the range of cross-sectional areas in infant, child, and adult ears, respectively. Equivalent ear canal volume and peSPL measurements were then recorded in child and adult ears. Lower intensity levels were used in the participant’s ears to limit exposure to high intensity sound. The peSPL measurements in participant ears were extrapolated using predictions from linear mixed models to determine if equivalent ear canal volume significantly contributed to overall peSPL and to estimate the mean and 95% confidence intervals of peSPLs in child and adult ears when high intensity stimulus levels (100 dB nHL) are used for VEMP testing without exposing subjects to high-intensity stimuli. Results Measurements from the coupler and tubes suggested: 1) each stimuli was linear, 2) there were no

  19. Sheep as a large animal ear model: Middle-ear ossicular velocities and intracochlear sound pressure.

    PubMed

    Péus, Dominik; Dobrev, Ivo; Prochazka, Lukas; Thoele, Konrad; Dalbert, Adrian; Boss, Andreas; Newcomb, Nicolas; Probst, Rudolf; Röösli, Christof; Sim, Jae Hoon; Huber, Alexander; Pfiffner, Flurin

    2017-08-01

    Animals are frequently used for the development and testing of new hearing devices. Dimensions of the middle ear and cochlea differ significantly between humans and commonly used animals, such as rodents or cats. The sheep cochlea is anatomically more like the human cochlea in size and number of turns. This study investigated the middle-ear ossicular velocities and intracochlear sound pressure (ICSP) in sheep temporal bones, with the aim of characterizing the sheep as an experimental model for implantable hearing devices. Measurements were made on fresh sheep temporal bones. Velocity responses of the middle ear ossicles at the umbo, long process of the incus and stapes footplate were measured in the frequency range of 0.25-8 kHz using a laser Doppler vibrometer system. Results were normalized by the corresponding sound pressure level in the external ear canal (P EC ). Sequentially, ICSPs at the scala vestibuli and tympani were then recorded with custom MEMS-based hydrophones, while presenting identical acoustic stimuli. The sheep middle ear transmitted most effectively around 4.8 kHz, with a maximum stapes velocity of 0.2 mm/s/Pa. At the same frequency, the ICSP measurements in the scala vestibuli and tympani showed the maximum gain relative to the P EC (24 dB and 5 dB, respectively). The greatest pressure difference across the cochlear partition occurred between 4 and 6 kHz. A comparison between the results of this study and human reference data showed middle-ear resonance and best cochlear sensitivity at higher frequencies in sheep. In summary, sheep can be an appropriate large animal model for research and development of implantable hearing devices. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Middle ear infection (otitis media) (image)

    MedlinePlus

    Otitis media is an inflammation or infection of the middle ear. Acute otitis media (acute ear infection) occurs when there is ... which causes production of fluid or pus. Chronic otitis media occurs when the eustachian tube becomes blocked ...

  1. Alternative splicing of inner-ear-expressed genes.

    PubMed

    Wang, Yanfei; Liu, Yueyue; Nie, Hongyun; Ma, Xin; Xu, Zhigang

    2016-09-01

    Alternative splicing plays a fundamental role in the development and physiological function of the inner ear. Inner-ear-specific gene splicing is necessary to establish the identity and maintain the function of the inner ear. For example, exon 68 of Cadherin 23 (Cdh23) gene is subject to inner-ear-specific alternative splicing, and as a result, Cdh23(+ 68) is only expressed in inner ear hair cells. Alternative splicing along the tonotopic axis of the cochlea contributes to frequency tuning, particularly in lower vertebrates, such as chickens and turtles. Differential splicing of Kcnma1, which encodes for the α subunit of the Ca(2+)-activated K(+) channel (BK channel), has been suggested to affect the channel gating properties and is important for frequency tuning. Consequently, deficits in alternative splicing have been shown to cause hearing loss, as we can observe in Bronx Waltzer (bv) mice and Sfswap mutant mice. Despite the advances in this field, the regulation of alternative splicing in the inner ear remains elusive. Further investigation is also needed to clarify the mechanism of hearing loss caused by alternative splicing deficits.

  2. [Objective surgery -- advanced robotic devices and simulators used for surgical skill assessment].

    PubMed

    Suhánszki, Norbert; Haidegger, Tamás

    2014-12-01

    Robotic assistance became a leading trend in minimally invasive surgery, which is based on the global success of laparoscopic surgery. Manual laparoscopy requires advanced skills and capabilities, which is acquired through tedious learning procedure, while da Vinci type surgical systems offer intuitive control and advanced ergonomics. Nevertheless, in either case, the key issue is to be able to assess objectively the surgeons' skills and capabilities. Robotic devices offer radically new way to collect data during surgical procedures, opening the space for new ways of skill parameterization. This may be revolutionary in MIS training, given the new and objective surgical curriculum and examination methods. The article reviews currently developed skill assessment techniques for robotic surgery and simulators, thoroughly inspecting their validation procedure and utility. In the coming years, these methods will become the mainstream of Western surgical education.

  3. The rationale for combining an online audiovisual curriculum with simulation to better educate general surgery trainees.

    PubMed

    AlJamal, Yazan N; Ali, Shahzad M; Ruparel, Raaj K; Brahmbhatt, Rushin D; Yadav, Siddhant; Farley, David R

    2014-09-01

    Surgery interns' training has historically been weighted toward patient care, operative observation, and sleeping when possible. With more protected free time and less clinical time, real educational hours for trainees in 2013 are precious. We created a 20-session (3 hours each) simulation curriculum (with pre- and post-tests) and a 24/7 online audiovisual (AV) curriculum for surgery interns. Friday morning simulation sessions emphasize operative skills and judgment. AV clips (using operating room, whiteboard, and simulation center videos) take learners through 20 different general surgery operations with follow-up quizzes. We report our early experience with this novel setup. Thirty-two surgical interns (2012-2013) attended simulation sessions on 20 separate subjects (hernia, breast, hepatobiliary, endocrine, etc). Post-test scores improved (P < .05) and trainees enjoyed using surgical skills for 3 hours each Friday morning (mean, >4.5; Likert scale, 1-5). The AV curriculum feedback is similar (mean, >4.3) and usage is available 24/7 preparing learners for both operating room and simulation sessions. Most simulation sessions utilize low-fidelity models to keep costs <$50 per session. Scores on our semiannual Surgical Olympics (mean score of 49.6 in July vs 82.9 in January; P < .05) improved significantly, suggesting that interns are improving their surgical skills and knowledge. Residents enjoy and learn from the step-by-step, in-house, AV curriculum and both appreciate and thrive on the 'hands-on' simulation sessions mimicking operations they see in real operating rooms. The cost of these programs is not prohibitive and the programs offer simulated repetitions for duty-hour-regulated trainees. Copyright © 2014 Mosby, Inc. All rights reserved.

  4. [Application of computer-assisted 3D imaging simulation for surgery].

    PubMed

    Matsushita, S; Suzuki, N

    1994-03-01

    This article describes trends in application of various imaging technology in surgical planning, navigation, and computer aided surgery. Imaging information is essential factor for simulation in medicine. It includes three dimensional (3D) image reconstruction, neuro-surgical navigation, creating substantial model based on 3D imaging data and etc. These developments depend mostly on 3D imaging technique, which is much contributed by recent computer technology. 3D imaging can offer new intuitive information to physician and surgeon, and this method is suitable for mechanical control. By utilizing simulated results, we can obtain more precise surgical orientation, estimation, and operation. For more advancement, automatic and high speed recognition of medical imaging is being developed.

  5. Forgotten T-tube in the middle ear.

    PubMed

    Shakeel, Muhammad; Trinidade, Aaron; Khan, Imran; Ah-See, Kim Wong

    2012-05-01

    Retention within the middle ear cleft is an unusual complication of T-tube insertion. A 40-year-old woman with Kartagener's Syndrome presented with hearing impairment in the right ear. She was found to have a previously inserted Goode T-tube lying within the middle ear behind an intact drum. She underwent successful removal of the T-tube via a myringotomy, and a new tube was re-inserted. Migration of a T-tube into the middle ear cleft should always be kept in mind in patients who present with otological symptoms and have a history of T-tube insertion, even in the presence of an intact drum.

  6. Swimmer's ear

    MedlinePlus

    ... often gets better with the proper treatment. Possible Complications The infection may spread to other areas around the ear, including the skull bone. In older people or those who have diabetes, the infection may become severe. This condition is ...

  7. EARS: Electronic Access to Reference Service.

    PubMed

    Weise, F O; Borgendale, M

    1986-10-01

    Electronic Access to Reference Service (EARS) is a front end to the Health Sciences Library's electronic mail system, with links to the online public catalog. EARS, which became operational in September 1984, is accessed by users at remote sites with either a terminal or microcomputer. It is menu-driven, allowing users to request: a computerized literature search, reference information, a photocopy of a journal article, or a book. This paper traces the history of EARS and discusses its use, its impact on library staff and services, and factors that influence the diffusion of new technology.

  8. Physiological artifacts in scalp EEG and ear-EEG.

    PubMed

    Kappel, Simon L; Looney, David; Mandic, Danilo P; Kidmose, Preben

    2017-08-11

    A problem inherent to recording EEG is the interference arising from noise and artifacts. While in a laboratory environment, artifacts and interference can, to a large extent, be avoided or controlled, in real-life scenarios this is a challenge. Ear-EEG is a concept where EEG is acquired from electrodes in the ear. We present a characterization of physiological artifacts generated in a controlled environment for nine subjects. The influence of the artifacts was quantified in terms of the signal-to-noise ratio (SNR) deterioration of the auditory steady-state response. Alpha band modulation was also studied in an open/closed eyes paradigm. Artifacts related to jaw muscle contractions were present all over the scalp and in the ear, with the highest SNR deteriorations in the gamma band. The SNR deterioration for jaw artifacts were in general higher in the ear compared to the scalp. Whereas eye-blinking did not influence the SNR in the ear, it was significant for all groups of scalps electrodes in the delta and theta bands. Eye movements resulted in statistical significant SNR deterioration in both frontal, temporal and ear electrodes. Recordings of alpha band modulation showed increased power and coherence of the EEG for ear and scalp electrodes in the closed-eyes periods. Ear-EEG is a method developed for unobtrusive and discreet recording over long periods of time and in real-life environments. This study investigated the influence of the most important types of physiological artifacts, and demonstrated that spontaneous activity, in terms of alpha band oscillations, could be recorded from the ear-EEG platform. In its present form ear-EEG was more prone to jaw related artifacts and less prone to eye-blinking artifacts compared to state-of-the-art scalp based systems.

  9. Endoscopic Sinus Surgery Simulator as a teaching tool for anatomy education.

    PubMed

    Solyar, Alla; Cuellar, Hernando; Sadoughi, Babak; Olson, Todd R; Fried, Marvin P

    2008-07-01

    Virtual reality simulators provide an effective learning environment and are widely used. This study evaluated the Endoscopic Sinus Surgery Simulator (ES3; Lockheed Martin) as a tool for anatomic education. Two medical student groups (experimental, n = 8; control, n = 7) studied paranasal sinus anatomy using either the simulator or textbooks. Their knowledge was then tested on the identification of anatomic structures on a view of the nasal cavities. The mean scores were 9.4 +/- 0.5 and 5.1 +/- 3.0 out of 10 for the simulator and textbook groups, respectively (P = .009). Moreover, the simulator group completed the test in a significantly shorter time, 5.9 +/- 1.1 versus 8.3 +/- 2.0 minutes (P = .021). A survey asking the students to rate their respective study modality did not materialize significant differences. The ES3 can be an effective tool in teaching sinonasal anatomy. This study may help shape the future of anatomic education and the development of modern educational tools.

  10. Use of the 'real-ear to dial difference' to derive real-ear SPL from hearing level obtained with insert earphones.

    PubMed

    Munro, K J; Lazenby, A

    2001-10-01

    The electroacoustic characteristics of a hearing instrument are normally selected for individuals using data obtained during audiological assessment. The precise inter-relationship between the electroacoustic and audiometric variables is most readily appreciated when they have been measured at the same reference point, such as the tympanic membrane. However, it is not always possible to obtain the real-ear sound pressure level (SPL) directly if this is below the noise floor of the probe-tube microphone system or if the subject is unco-operative. The real-ear SPL may be derived by adding the subject's real-ear to dial difference (REDD) acoustic transform to the audiometer dial setting. The aim of the present study was to confirm the validity of the Audioscan RM500 to measure the REDD with the ER-3A insert earphone. A probe-tube microphone was used to measure the real-ear SPL and REDD from the right ears of 16 adult subjects ranging in age from 22 to 41 years (mean age 27 years). Measurements were made from 0.25 kHz to 6 kHz at a dial setting of 70 dB with an ER-3A insert earphone and two earmould configurations: the EAR-LINK foam ear-tip and the subjects' customized skeleton earmoulds. Mean REDD varied as a function of frequency but was typically approximately 12 dB with a standard deviation (SD) of +/- 1.7 dB and +/- 2.7 dB for the foam ear-tip and customized earmould, respectively. The mean test-retest difference of the REDD varied with frequency but was typically 0.5 dB (SD 1 dB). Over the frequency range 0.5-4 kHz, the derived values were found to be within 5 dB of the measured values in 95% of subjects when using the EAR-LINK foam ear-tip and within 4 dB when using the skeleton earmould. The individually measured REDD transform can be used in clinical practice to derive a valid estimate of real-ear SPL when it has not been possible to measure this directly.

  11. Structures that Contribute to Middle-Ear Admittance in Chinchilla

    PubMed Central

    Rosowski, John J.; Ravicz, Michael E.; Songer, Jocelyn E.

    2009-01-01

    We describe measurements of middle-ear input admittance in chinchillas (Chinchilla lanigera) before and after various manipulations that define the contributions of different middle-ear components to function. The chinchilla’s middle-ear air spaces have a large effect on the low-frequency compliance of the middle ear, and removing the influences of these spaces reveals a highly admittant tympanic membrane and ossicular chain. Measurements of the admittance of the air spaces reveal that the high-degree of segmentation of these spaces has only a small effect on the admittance. Draining the cochlea further increases the middle-ear admittance at low frequencies and removes a low-frequency (less than 300 Hz) level dependence in the admittance. Spontaneous or sound-driven contractions of the middle-ear muscles in deeply anesthetized animals were associated with significant changes in middle-ear admittance. PMID:16944166

  12. Cauliflower Ear and Skin Infections among Wrestlers in Tehran.

    PubMed

    Kordi, Ramin; Mansournia, Mohammad Ali; Nourian, Roh Allah; Wallace, W Angus

    2007-01-01

    The purpose of the study was to describe the magnitude of the selected sports medicine problems (i.e. cauliflower ear and skin infections) among wrestlers in Tehran. A number of 411 wrestlers were randomly selected from wrestling clubs in Tehran employing cluster sample setting method. The participants were interviewed using a specially designed and validated questionnaire. Nearly half of the participants (44%) had "cauliflower ears". Only 23% of these participants had received any kind of treatment for their acute ear haematomas that are known to result in "cauliflower ears". The prevalence of reported hearing loss among participants with cauliflower ears (11.5%, 95%CI: 6.9 to 16.2) was significantly more than this prevalence among those participants without cauliflower ears (1.8%, 95%CI: 0.1 to 3.5) (p < 0.05). More than half of the participants (52%) had skin infection diagnosed by a physician during the previous year. This study has identified evidence of an increase in hearing loss as a possible side effect of either cauliflower ear or ear injury in wrestling in Iran. There has been an outbreak of ringworm and there is a significant potential for an outbreak of impetigo among wrestlers in Tehran. Key pointsSkin infections are prevalent among wrestlers in Tehran.Commonly wrestlers in Tehran continue to carry out wrestling training while affected by skin infections.Cauliflower ear "is common among wrestlers in Tehran.More research is needed to investigate hearing loss as a possible side effect of either cauliflower ear or ear injury in wrestling in Iran.

  13. Realistic soft tissue deformation strategies for real time surgery simulation.

    PubMed

    Shen, Yunhe; Zhou, Xiangmin; Zhang, Nan; Tamma, Kumar; Sweet, Robert

    2008-01-01

    A volume-preserving deformation method (VPDM) is developed in complement with the mass-spring method (MSM) to improve the deformation quality of the MSM to model soft tissue in surgical simulation. This method can also be implemented as a stand-alone model. The proposed VPDM satisfies the Newton's laws of motion by obtaining the resultant vectors form an equilibrium condition. The proposed method has been tested in virtual surgery systems with haptic rendering demands.

  14. Knowledge, Attitude and Practice of Ear Care in Coastal Karnataka.

    PubMed

    Dosemane, Deviprasad; Ganapathi, Keerthan; Kanthila, Jayashree

    2015-12-01

    Ear as an organ is necessary for the perception of sound and body balance. Ear infection, diabetes mellitus, hypertension and excessive use of mobile phone for listening to music at high volume all can reduce hearing. No earlier study was available in the costal Karnataka population, regarding the practice of ear care. The study objective was to ascertain the level of knowledge of the community regarding ear care, to find out whether some of the common conditions affecting hearing are known and to find out the common practices involved in maintaining ear hygiene. This cross-sectional study was conducted on 500 subjects in two tertiary care hospitals by convenient sampling, using self-administered questionnaire. Knowledge, Attitude and Practice across the age groups, religion & education background were studied. Across different education groups, 66.7%-90% did not know that 'cold' can cause ear infection and 46.7%-75.0% did not know that diabetes and hypertension can reduce hearing. When there is ear pain or discharge, people put ear drops available at home in 48.3%-75.0% across 3 age groups; 58.5%-61.5% across 3 religions and 44.8%-67.9% across 5 education groups. No statistically significant difference was found in the practice of pouring oil into ears across religions. A total of 58.6%-100% daily clean inside the ear and 70-100% use cotton buds. General perception of the people is that ear is necessary only for hearing. Majority did not know that nasal infection can affect the ear and that DM and hypertension can cause hearing loss. When there is ear pain and discharge, most of the adults put drops that are available at home. Pouring oil into the ears and cleaning inside the ear canals is routinely practiced in costal Karnataka.

  15. [Severe Bleeding from the Middle Ear Cavity after Myringotomy: Review Based on a Case Report].

    PubMed

    Hofmann, Veit M; Niehues, Stefan M; Albers, Andreas E; Pudszuhn, Annett

    2017-03-01

    Report of a rare case of severe bleeding from the middle ear cavity after myringotomy. On the basis of the case report, the procedure for such bleeding is discussed in the context of the literature. A 6-year-old boy received a revision myringotomy in an ambulant setting. During the procedure a severe bleeding occurred. The external auditory canal was adequately packed. The patient was extubated and transferred to the clinic as an emergency. Computer tomography of the temporal bone showed the anatomical variant of a dehiscent high jugular bulb, which had been injured. Because no rebleeding occurred, the packing of the ear canal was removed and an explorative tympanoscopy was performed on the third postoperative day. When the tympanomeatal flap was lifted, the defect in the jugular bulb was found. The lesion was covered with Tutopatch ® pads and fibrin glue and the auditory canal was packed again. After removal of the packing three weeks postoperatively a properly healed situs was found. No further measures were taken. The injury of a dehiscent jugular bulb in the course of ear surgeries leads to a massive hemorrhage. The case describes the diagnostic and therapeutic procedure for this relatively rare but severe complication. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Major evolutionary transitions and innovations: the tympanic middle ear

    PubMed Central

    2017-01-01

    One of the most amazing transitions and innovations during the evolution of mammals was the formation of a novel jaw joint and the incorporation of the original jaw joint into the middle ear to create the unique mammalian three bone/ossicle ear. In this review, we look at the key steps that led to this change and other unusual features of the middle ear and how developmental biology has been providing an understanding of the mechanisms involved. This starts with an overview of the tympanic (air-filled) middle ear, and how the ear drum (tympanic membrane) and the cavity itself form during development in amniotes. This is followed by an investigation of how the ear is connected to the pharynx and the relationship of the ear to the bony bulla in which it sits. Finally, the novel mammalian jaw joint and versatile dentary bone will be discussed with respect to evolution of the mammalian middle ear. This article is part of the themed issue ‘Evo-devo in the genomics era, and the origins of morphological diversity’. PMID:27994124

  17. Identifying position, visibility, dimensions, and angulation of the ear.

    PubMed

    Mohamed, Kasim; Christian, Jayanth; Jeyapalan, Karthigeyan; Natarajan, Shanmuganathan; Banu, Fathima; Veeravalli, Padmanabhan T

    2014-01-01

    We selected 254 subjects between the ages of 18 and 30 yr to assess the ear position, angulations of the ear in relation to the nose, visibility from the frontal view, and dimensions of the ear by using various anthropometric points of the face. Subjects were divided into four groups based on facial form. A reference plane indicator, facial topographical measurements, metal ruler, and digital photography were used. While considering the position of the ear, in all facial forms except square tapering, the most samples showed a tendency for the subaurale being in line with subnasale. Regression analysis showed a tendency to gnathion distance is the most dependent variable with length of the ear kept as a constant predictor, while both interalar distance and exocanthion to endocanthion distance correlate highly significantly to the width of the ear. In all subjects, the visibility of the ear when viewed from the front was an average of 1.5 mm. Regardless of facial form, ear angulation was generally less than nose angulation.

  18. Nonsurgical correction of congenital ear abnormalities in the newborn: Case series.

    PubMed

    Smith, Wg; Toye, Jw; Reid, A; Smith, Rw

    2005-07-01

    To determine whether a simple, nonsurgical treatment for congenital ear abnormalities (lop-ear, Stahl's ear, protruding ear, cryptotia) improved the appearance of ear abnormalities in newborns at six weeks of age. This is a descriptive case series. All newborns with identified abnormalities were referred by their family physician to one paediatrician (WGS) in a small level 2 perinatal centre. The ears were waxed and taped in a standard manner within 10 days of birth. Pictures were taken before taping and at the end of taping (one month). All patients and pictures were assessed by one plastic surgeon (JWT) at six weeks of age and scored using a standard scoring system. A telephone survey of the nontreatment group was conducted. The total number of ears assessed was 90. Of this total, 69 ears were taped and fully evaluated in the study (77%). The refusal rate was 23%. In the treatment group, 59% had lop-ear, 19% had Stahl's ear, 17% had protruding ear and 3% had cryptotia. Overall correction (excellent/improved) for the treatment group was 90% (100% for lop-ear, 100% for Stahl's ear, 67% for protruding ear and 0% for cryptotia). In the nontreatment (refusal) group, 67% of the ears failed to correct spontaneously. No complications were recognized by the authors or parents by six weeks. The percentage of newborns in one year in the perinatal centre with recognized ear abnormalities was 6% (90 of 1600). A simple, nonsurgical treatment in a Caucasian population appeared to be very effective in correcting congenital ear abnormalities with no complications and high patient/parent satisfaction.

  19. Primary investigations on the potential of a novel diode pumped Er:YAG laser system for middle ear surgery

    NASA Astrophysics Data System (ADS)

    Stock, Karl; Wurm, Holger; Hausladen, Florian

    2016-02-01

    Flashlamp pumped Er:YAG lasers are successfully used clinically for both precise soft and hard tissue ablation. Since several years a novel diode pumped Er:YAG laser system (Pantec Engineering AG) is available, with mean laser power up to 40 W and pulse repetition rate up to 1 kHz. The aim of the study was to investigate the suitability of the laser system specifically for stapedotomy. Firstly an experimental setup was realized with a beam focusing unit and a computer controlled translation stage to move the samples (slices of porcine bone) with a defined velocity while irradiation with various laser parameters. A microphone was positioned in a defined distance to the ablation point and the resulting acoustic signal of the ablation process was recorded. For comparison, measurements were also performed with a flash lamp pumped Er:YAG laser system. After irradiation the resulting ablation quality and efficacy were determined using light microscopy. Using a high speed camera and "Töpler-Schlierentechnik" the cavitation bubble in water after perforation of a bone slice was investigated. The results show efficient bone ablation using the diode pumped Er:YAG laser system. Also a decrease of the sound level and of the cavitation bubble volume was observed with decreasing pulse duration. Higher repetition rates lead to a slightly increase of thermal side effects but have no influence on the ablation efficiency. In conclusion, these first experiments demonstrate the high potential of the diode pumped Er:YAG laser system for use in middle ear surgery.

  20. Neonatal Ear Molding: Timing and Technique.

    PubMed

    Anstadt, Erin Elizabeth; Johns, Dana Nicole; Kwok, Alvin Chi-Ming; Siddiqi, Faizi; Gociman, Barbu

    2016-03-01

    The incidence of auricular deformities is believed to be ∼11.5 per 10,000 births, excluding children with microtia. Although not life-threatening, auricular deformities can cause undue distress for patients and their families. Although surgical procedures have traditionally been used to reconstruct congenital auricular deformities, ear molding has been gaining acceptance as an efficacious, noninvasive alternative for the treatment of newborns with ear deformations. We present the successful correction of bilateral Stahl's ear deformity in a newborn through a straightforward, nonsurgical method implemented on the first day of life. The aim of this report is to make pediatric practitioners aware of an effective and simple molding technique appropriate for correction of congenital auricular anomalies. In addition, it stresses the importance of very early initiation of ear cartilage molding for achieving the desired outcome. Copyright © 2016 by the American Academy of Pediatrics.

  1. Milestones in the History of Ear Reconstruction.

    PubMed

    Berghaus, Alexander; Nicoló, Marion San

    2015-12-01

    The reconstruction of ear deformities has been challenging plastic surgeons since centuries. However, it is only in the 19th century that reports on partial and total ear reconstruction start increasing. In the quest for an aesthetically pleasing and natural-looking result, surgeons worked on the perfect framework and skin coverage. Different materials and flap techniques have evolved. Some were abandoned out of frustration, while others kept evolving over the years. In this article, we discuss the milestones in ear reconstruction-from ancient times to early attempts in Western civilization to the key chapters of ear reconstruction in the 20th century leading to the current techniques. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  2. Force-Sensing Enhanced Simulation Environment (ForSense) for laparoscopic surgery training and assessment.

    PubMed

    Cundy, Thomas P; Thangaraj, Evelyn; Rafii-Tari, Hedyeh; Payne, Christopher J; Azzie, Georges; Sodergren, Mikael H; Yang, Guang-Zhong; Darzi, Ara

    2015-04-01

    Excessive or inappropriate tissue interaction force during laparoscopic surgery is a recognized contributor to surgical error, especially for robotic surgery. Measurement of force at the tool-tissue interface is, therefore, a clinically relevant skill assessment variable that may improve effectiveness of surgical simulation. Popular box trainer simulators lack the necessary technology to measure force. The aim of this study was to develop a force sensing unit that may be integrated easily with existing box trainer simulators and to (1) validate multiple force variables as objective measurements of laparoscopic skill, and (2) determine concurrent validity of a revised scoring metric. A base plate unit sensitized to a force transducer was retrofitted to a box trainer. Participants of 3 different levels of operative experience performed 5 repetitions of a peg transfer and suture task. Multiple outcome variables of force were assessed as well as a revised scoring metric that incorporated a penalty for force error. Mean, maximum, and overall magnitudes of force were significantly different among the 3 levels of experience, as well as force error. Experts were found to exert the least force and fastest task completion times, and vice versa for novices. Overall magnitude of force was the variable most correlated with experience level and task completion time. The revised scoring metric had similar predictive strength for experience level compared with the standard scoring metric. Current box trainer simulators can be adapted for enhanced objective measurements of skill involving force sensing. These outcomes are significantly influenced by level of expertise and are relevant to operative safety in laparoscopic surgery. Conventional proficiency standards that focus predominantly on task completion time may be integrated with force-based outcomes to be more accurately reflective of skill quality. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. A step-by-step development of real-size chest model for simulation of thoracoscopic surgery.

    PubMed

    Morikawa, Toshiaki; Yamashita, Makoto; Odaka, Makoto; Tsukamoto, Yo; Shibasaki, Takamasa; Mori, Shohei; Asano, Hisatoshi; Akiba, Tadashi

    2017-08-01

    For the purpose of simulating thoracoscopic surgery, we have conducted stepwise development of a life-like chest model including thorax and intrathoracic organs. First, CT data of the human chest were obtained. First-generation model: based on the CT data, each component of the chest was made from a 3D printer. A hard resin was used for the bony thorax and a rubber-like resin for the vessels and bronchi. Lung parenchyma, muscles and skin were not created. Second-generation model: in addition to the 3D printer, a cast moulding method was used. Each part was casted using a 3D printed master and then assembled. The vasculature and bronchi were casted using silicon resin. The lung parenchyma and mediastinum organs were casted using urethane foam. Chest wall and bony thorax were also casted using a silicon resin. Third-generation model: foamed polyvinyl alcohol (PVA) was newly developed and casted onto the lung parenchyma. The vasculature and bronchi were developed using a soft resin. A PVA plate was made as the mediastinum, and all were combined. The first-generation model showed real distribution of the vasculature and bronchi; it enabled an understanding of the anatomy within the lung. The second-generation model is a total chest dry model, which enabled observation of the total anatomy of the organs and thorax. The third-generation model is a wet organ model. It allowed for realistic simulation of surgical procedures, such as cutting, suturing, stapling and energy device use. This single-use model achieved realistic simulation of thoracoscopic surgery. As the generation advances, the model provides a more realistic simulation of thoracoscopic surgery. Further improvement of the model is needed. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  4. "Just-In-Time" Simulation Training Using 3-D Printed Cardiac Models After Congenital Cardiac Surgery.

    PubMed

    Olivieri, Laura J; Su, Lillian; Hynes, Conor F; Krieger, Axel; Alfares, Fahad A; Ramakrishnan, Karthik; Zurakowski, David; Marshall, M Blair; Kim, Peter C W; Jonas, Richard A; Nath, Dilip S

    2016-03-01

    High-fidelity simulation using patient-specific three-dimensional (3D) models may be effective in facilitating pediatric cardiac intensive care unit (PCICU) provider training for clinical management of congenital cardiac surgery patients. The 3D-printed heart models were rendered from preoperative cross-sectional cardiac imaging for 10 patients undergoing congenital cardiac surgery. Immediately following surgical repair, a congenital cardiac surgeon and an intensive care physician conducted a simulation training session regarding postoperative care utilizing the patient-specific 3D model for the PCICU team. After the simulation, Likert-type 0 to 10 scale questionnaire assessed participant perception of impact of the training session. Seventy clinicians participated in training sessions, including 22 physicians, 38 nurses, and 10 ancillary care providers. Average response to whether 3D models were more helpful than standard hand off was 8.4 of 10. Questions regarding enhancement of understanding and clinical ability received average responses of 9.0 or greater, and 90% of participants scored 8 of 10 or higher. Nurses scored significantly higher than other clinicians on self-reported familiarity with the surgery (7.1 vs. 5.8; P = .04), clinical management ability (8.6 vs. 7.7; P = .02), and ability enhancement (9.5 vs. 8.7; P = .02). Compared to physicians, nurses and ancillary providers were more likely to consider 3D models more helpful than standard hand off (8.7 vs. 7.7; P = .05). Higher case complexity predicted greater enhancement of understanding of surgery (P = .04). The 3D heart models can be used to enhance congenital cardiac critical care via simulation training of multidisciplinary intensive care teams. Benefit may be dependent on provider type and case complexity. © The Author(s) 2016.

  5. High-throughput method for ear phenotyping and kernel weight estimation in maize using ear digital imaging.

    PubMed

    Makanza, R; Zaman-Allah, M; Cairns, J E; Eyre, J; Burgueño, J; Pacheco, Ángela; Diepenbrock, C; Magorokosho, C; Tarekegne, A; Olsen, M; Prasanna, B M

    2018-01-01

    Grain yield, ear and kernel attributes can assist to understand the performance of maize plant under different environmental conditions and can be used in the variety development process to address farmer's preferences. These parameters are however still laborious and expensive to measure. A low-cost ear digital imaging method was developed that provides estimates of ear and kernel attributes i.e., ear number and size, kernel number and size as well as kernel weight from photos of ears harvested from field trial plots. The image processing method uses a script that runs in a batch mode on ImageJ; an open source software. Kernel weight was estimated using the total kernel number derived from the number of kernels visible on the image and the average kernel size. Data showed a good agreement in terms of accuracy and precision between ground truth measurements and data generated through image processing. Broad-sense heritability of the estimated parameters was in the range or higher than that for measured grain weight. Limitation of the method for kernel weight estimation is discussed. The method developed in this work provides an opportunity to significantly reduce the cost of selection in the breeding process, especially for resource constrained crop improvement programs and can be used to learn more about the genetic bases of grain yield determinants.

  6. Cochlear pharmacokinetics with local inner ear drug delivery using a three-dimensional finite-element computer model.

    PubMed

    Plontke, Stefan K; Siedow, Norbert; Wegener, Raimund; Zenner, Hans-Peter; Salt, Alec N

    2007-01-01

    Cochlear fluid pharmacokinetics can be better represented by three-dimensional (3D) finite-element simulations of drug dispersal. Local drug deliveries to the round window membrane are increasingly being used to treat inner ear disorders. Crucial to the development of safe therapies is knowledge of drug distribution in the inner ear with different delivery methods. Computer simulations allow application protocols and drug delivery systems to be evaluated, and may permit animal studies to be extrapolated to the larger cochlea of the human. A finite-element 3D model of the cochlea was constructed based on geometric dimensions of the guinea pig cochlea. Drug propagation along and between compartments was described by passive diffusion. To demonstrate the potential value of the model, methylprednisolone distribution in the cochlea was calculated for two clinically relevant application protocols using pharmacokinetic parameters derived from a prior one-dimensional (1D) model. In addition, a simplified geometry was used to compare results from 3D with 1D simulations. For the simplified geometry, calculated concentration profiles with distance were in excellent agreement between the 1D and the 3D models. Different drug delivery strategies produce very different concentration time courses, peak concentrations and basal-apical concentration gradients of drug. In addition, 3D computations demonstrate the existence of substantial gradients across the scalae in the basal turn. The 3D model clearly shows the presence of drug gradients across the basal scalae of guinea pigs, demonstrating the necessity of a 3D approach to predict drug movements across and between scalae with larger cross-sectional areas, such as the human, with accuracy. This is the first model to incorporate the volume of the spiral ligament and to calculate diffusion through this structure. Further development of the 3D model will have to incorporate a more accurate geometry of the entire inner ear and

  7. Cochlear Pharmacokinetics with Local Inner Ear Drug Delivery Using a Three-Dimensional Finite-Element Computer Model

    PubMed Central

    Plontke, Stefan K.; Siedow, Norbert; Wegener, Raimund; Zenner, Hans-Peter; Salt, Alec N.

    2006-01-01

    Hypothesis: Cochlear fluid pharmacokinetics can be better represented by three-dimensional (3D) finite-element simulations of drug dispersal. Background: Local drug deliveries to the round window membrane are increasingly being used to treat inner ear disorders. Crucial to the development of safe therapies is knowledge of drug distribution in the inner ear with different delivery methods. Computer simulations allow application protocols and drug delivery systems to be evaluated, and may permit animal studies to be extrapolated to the larger cochlea of the human. Methods: A finite-element 3D model of the cochlea was constructed based on geometric dimensions of the guinea pig cochlea. Drug propagation along and between compartments was described by passive diffusion. To demonstrate the potential value of the model, methylprednisolone distribution in the cochlea was calculated for two clinically relevant application protocols using pharmacokinetic parameters derived from a prior one-dimensional (1D) model. In addition, a simplified geometry was used to compare results from 3D with 1D simulations. Results: For the simplified geometry, calculated concentration profiles with distance were in excellent agreement between the 1D and the 3D models. Different drug delivery strategies produce very different concentration time courses, peak concentrations and basal-apical concentration gradients of drug. In addition, 3D computations demonstrate the existence of substantial gradients across the scalae in the basal turn. Conclusion: The 3D model clearly shows the presence of drug gradients across the basal scalae of guinea pigs, demonstrating the necessity of a 3D approach to predict drug movements across and between scalae with larger cross-sectional areas, such as the human, with accuracy. This is the first model to incorporate the volume of the spiral ligament and to calculate diffusion through this structure. Further development of the 3D model will have to incorporate a more

  8. EARS: Electronic Access to Reference Service.

    PubMed Central

    Weise, F O; Borgendale, M

    1986-01-01

    Electronic Access to Reference Service (EARS) is a front end to the Health Sciences Library's electronic mail system, with links to the online public catalog. EARS, which became operational in September 1984, is accessed by users at remote sites with either a terminal or microcomputer. It is menu-driven, allowing users to request: a computerized literature search, reference information, a photocopy of a journal article, or a book. This paper traces the history of EARS and discusses its use, its impact on library staff and services, and factors that influence the diffusion of new technology. PMID:3779167

  9. Physically Based Virtual Surgery Planning and Simulation Tools for Personal Health Care Systems

    NASA Astrophysics Data System (ADS)

    Dogan, Firat; Atilgan, Yasemin

    The virtual surgery planning and simulation tools have gained a great deal of importance in the last decade in a consequence of increasing capacities at the information technology level. The modern hardware architectures, large scale database systems, grid based computer networks, agile development processes, better 3D visualization and all the other strong aspects of the information technology brings necessary instruments into almost every desk. The last decade’s special software and sophisticated super computer environments are now serving to individual needs inside “tiny smart boxes” for reasonable prices. However, resistance to learning new computerized environments, insufficient training and all the other old habits prevents effective utilization of IT resources by the specialists of the health sector. In this paper, all the aspects of the former and current developments in surgery planning and simulation related tools are presented, future directions and expectations are investigated for better electronic health care systems.

  10. Pilot study on verification of effectiveness on operability of assistance system for robotic tele-surgery using simulation.

    PubMed

    Kawamura, Kazuya; Kobayashi, Yo; Fujie, Masakatsu G

    2010-01-01

    Tele-surgery enables medical care even in remote regions, and has been accomplished in clinical cases by means of dedicated communication lines. To make tele-surgery a more widespread method of providing medical care, a surgical environment needs to be made available using public lines of communication, such as the Internet. Moreover, a support system during surgery is required, as the use of surgical tools is performed in an environment subject to delay. In our research, we focus on the operability of specific tasks conducted by surgeons during a medical procedure, with the aim of clarifying, by means of a simulation, the optimum environment for robotic tele-surgery. In the study, we set up experimental systems using our proposed simulation system. In addition, we investigate the mental workloads on subjects and verify the effect of visual-assistance information as a pilot study. The operability of the task of gripping soft tissue was evaluated using a subjective workload assessment tool, the NASA Task Load Index. Results show that the tasks were completed, but the workload did not improve to less than 300ms and 400ms in the simulated environment. Verifying the effect of the support system was an important task under a more-than 200ms delay using this experiment, and future studies will evaluate the operability of the system under varying conditions of comfort. In addition, an intra-operative assistance system will be constructed using a simulation.

  11. Anatomical variants of tympanic compartments and their aeration pathways involved in the pathogenesis of middle ear inflammatory disease

    PubMed Central

    MANIU, ALMA; CATANA, IULIU V.; HARABAGIU, OANA; PETRI, MARIA; COSGAREA, MARCEL

    2013-01-01

    Aim The aim of this article is to review the anatomy of middle ear compartments and folds and to demonstrate through anatomical evidence their presence at birth. Additionally, their role in the obstructions of middle ear ventilatory pathway is highlighted. Methods Ninety-eight adult temporal bones, with no history of auricular disease and fifteen newborn temporal bones were studied by micro dissection. Documentation was done by color photography using the operation microscope Results Our micro-dissections have showed that mucosal folds from the middle ear are steadily present since birth, given that they were found in all newborn temporal bones. The mucosal folds in our normal adult material, showed some variations including membrane defects but they were constantly present. Our micro dissections showed that the epitympanic diaphragm consisted, in addition to malleal ligamental folds and ossicles, of only two constantly present folds: the tensor tympani fold and the incudomalleal fold. When the tensor fold is complete the only ventilation pathway to the anterior epitympanic space is through the isthmus, whereas its absence creates an efficient additional aeration route from the Eustachian tube to the epitympanum. Conclusions The goal of surgery in the chronic pathology of the middle ear should be restoration of normal ventilation of the attical-mastoid area. This is possible by removing the tensor fold and restoring the functionality of the isthmus tympani. PMID:26527977

  12. Minimally invasive functional approach for cholesteatoma surgery.

    PubMed

    Hanna, Bassem M; Kivekäs, Ilkka; Wu, Yi-Hsuan; Guo, Lee J; Lin, Huang; Guidi, Jessica; Poe, Dennis

    2014-10-01

    Report the efficacy of a functional minimally invasive approach for cholesteatoma surgery. Retrospective review of surgical cases performed between 1996 and 2008. One hundred sixty-nine patient charts were reviewed in which ears with primary cholesteatomas that extended beyond the mesotympanum were operated on with a plan for canal wall up (CWU) mastoidectomy. The surgical approach consisted of progressive exposure from transcanal to postauricular tympanoplasty to CWU mastoidectomy, as needed, to identify and lyse the fibrous attachments that bind the capsule to the surrounding mucosa. Endoscopic guidance was employed as appropriate to minimize exposure needs. Any planned second-stage operations were attempted with a transcanal approach if appropriate and with endoscopic assistance. One hundred eighty-four ears of 169 patients were included. The median age was 32 years (range, 1-79 years). The mean follow-up was 3.2 years (range, 1-11 years). Eighty-three (45%) were planned for a second-look operation, and three (2%) required unplanned second operations. The overall recurrence rate was 24/184 (13%), and the unexpected residual rate was 5/184 (3%). The residual rate with endoscopy (5/119, 4%,) or without endoscopy (1/65, 2%), were not significantly different. Hearing results in 156 ears improved significantly, from a preoperative pure-tone average (PTA) of 41 dB to a postoperative PTA average of 29 dB (P < .0001). A functional minimally invasive approach to cholesteatoma surgery provided equivalent residual rates but higher recurrence rates compared to published canal wall down mastoidectomy. Endoscopic techniques were helpful in providing adequate views while minimizing exposure. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  13. [High-resolution computed tomography in stapes surgery].

    PubMed

    Oberascher, G; Grobovschek, M

    1987-06-01

    Early and delayed complications in the inner or middle ear may follow stapedectomy or stapedotomy and may require revision surgery. Nowadays high resolution middle ear computed tomography (HR-MCT) using a special interpolation technique can demonstrate the smallest structures of the middle ear space, such as the long process of the incus and stapes. Stapes prostheses can also be seen in this way, but to identify the prothesis exactly it is necessary to determine the position of the piston hook in relation to the incus and of the piston shaft to the foot plate and scala vestibuli. Two points were of particular interest to us: HR-MCT identification of various metal and plastic pistons. Clinical significance of HR-MCT in complications following surgery. As the result of our experimental research on cadaver temporal bones, pistons must still be divided into four groups based on their demonstration by HR-MCT: Group I (e.g. Stainless Steel Cup Piston): whole piston visible. Group II (e.g. McGee Stainless Steel Piston): only piston shaft. Group III (Fisch Teflon-Platinum Piston): only hook visible. Group IV (e.g. Fisch Teflon-Wire Piston): piston hardly visible or not at all. In groups I-III it is possible to discover whether the piston is too long or too short, whether it is dislocated or has slipped. Group IV pistons, hooks from group II and the shaft from group III must be changed to allow detection by x-rays. With plastic pistons it might be possible to add an x-ray agent.2+ improvements in manufacture appear to be necessary, dislocation of various prostheses can now be shown.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. A novel augmented reality simulator for skills assessment in minimal invasive surgery.

    PubMed

    Lahanas, Vasileios; Loukas, Constantinos; Smailis, Nikolaos; Georgiou, Evangelos

    2015-08-01

    Over the past decade, simulation-based training has come to the foreground as an efficient method for training and assessment of surgical skills in minimal invasive surgery. Box-trainers and virtual reality (VR) simulators have been introduced in the teaching curricula and have substituted to some extent the traditional model of training based on animals or cadavers. Augmented reality (AR) is a new technology that allows blending of VR elements and real objects within a real-world scene. In this paper, we present a novel AR simulator for assessment of basic laparoscopic skills. The components of the proposed system include: a box-trainer, a camera and a set of laparoscopic tools equipped with custom-made sensors that allow interaction with VR training elements. Three AR tasks were developed, focusing on basic skills such as perception of depth of field, hand-eye coordination and bimanual operation. The construct validity of the system was evaluated via a comparison between two experience groups: novices with no experience in laparoscopic surgery and experienced surgeons. The observed metrics included task execution time, tool pathlength and two task-specific errors. The study also included a feedback questionnaire requiring participants to evaluate the face-validity of the system. Between-group comparison demonstrated highly significant differences (<0.01) in all performance metrics and tasks denoting the simulator's construct validity. Qualitative analysis on the instruments' trajectories highlighted differences between novices and experts regarding smoothness and economy of motion. Subjects' ratings on the feedback questionnaire highlighted the face-validity of the training system. The results highlight the potential of the proposed simulator to discriminate groups with different expertise providing a proof of concept for the potential use of AR as a core technology for laparoscopic simulation training.

  15. Inner ear problems of Thai priest at Priest Hospital.

    PubMed

    Karnchanakas, Taweporn; Tantanavat, Are; Sinsakontavat, Jamjan

    2008-01-01

    The inner ear problems of Thai priest at Priest Hospital had never been reported previously, so Department of Ear Nose Throat try to correlate the metebotic disorder with inner ear problems. 1) To study the fasting blood sugar (FBS), total cholesterol (T. Chol), low density lipoprotein (LDL), and triglyceride (TG), the factors expected to involve in inner ear problems of priests at Priest Hospital. 2) To compare the FBS, T. Chol, HDL, LDL, and TG of priests with inner ear problems at Priest Hospital. 3) To find the percentage of abnormal from FBS, T. Chol, LDL, and TG. The study using 83 sampling of priests with inner ear problems and 107 priests as a controlled group. The research instruments used to collect data was the questionnaire which composed of general information, physical, ear-nose-throat and neurological examination, pure tone audiometry, brainstem evoke response audiometry (BERA) and the blood tests:FBS, T. Chol, TG, and LDL. The inner ear problems were composed of: 1) Dizziness 2) Hearing Loss 3) Tinnitus Aurium. The descriptive statistics were used to analyze the data from questionnaires and utilized frequency, percentage, standard deviation (S.D.) and t-test to achieve desired results. Priest at middle age and elderly with inner ear problems had greater FBS and TG than expected values of the control group. The middle age and elderly priests who had greater FBS and TG than expected values were sick with inner ear problems that causing dizziness, hearing loss and tinnitus aurium.

  16. A National Needs Assessment to Identify Technical Procedures in Vascular Surgery for Simulation Based Training.

    PubMed

    Nayahangan, L J; Konge, L; Schroeder, T V; Paltved, C; Lindorff-Larsen, K G; Nielsen, B U; Eiberg, J P

    2017-04-01

    Practical skills training in vascular surgery is facing challenges because of an increased number of endovascular procedures and fewer open procedures, as well as a move away from the traditional principle of "learning by doing." This change has established simulation as a cornerstone in providing trainees with the necessary skills and competences. However, the development of simulation based programs often evolves based on available resources and equipment, reflecting convenience rather than a systematic educational plan. The objective of the present study was to perform a national needs assessment to identify the technical procedures that should be integrated in a simulation based curriculum. A national needs assessment using a Delphi process was initiated by engaging 33 predefined key persons in vascular surgery. Round 1 was a brainstorming phase to identify technical procedures that vascular surgeons should learn. Round 2 was a survey that used a needs assessment formula to explore the frequency of procedures, the number of surgeons performing each procedure, risk and/or discomfort, and feasibility for simulation based training. Round 3 involved elimination and ranking of procedures. The response rate for round 1 was 70%, with 36 procedures identified. Round 2 had a 76% response rate and resulted in a preliminary prioritised list after exploring the need for simulation based training. Round 3 had an 85% response rate; 17 procedures were eliminated, resulting in a final prioritised list of 19 technical procedures. A national needs assessment using a standardised Delphi method identified a list of procedures that are highly suitable and may provide the basis for future simulation based training programs for vascular surgeons in training. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  17. Evidence for a Right-Ear Advantage in Newborn Hearing Screening Results

    PubMed Central

    Hildesheimer, Minka; Roziner, Ilan; Henkin, Yael

    2016-01-01

    The aim of the present study was to investigate the effect of ear asymmetry, order of testing, and gender on transient-evoked otoacoustic emission (TEOAE) pass rates and response levels in newborn hearing screening. The screening results of 879 newborns, of whom 387 (study group) passed screening successfully in only one ear in the first TEOAE screening, but passed screening successfully in both ears thereafter, and 492 (control group) who passed screening successfully in both ears in the first TEOAE, were retrospectively examined for pass rates and TEOAE characteristics. Results indicated a right-ear advantage, as manifested by significantly higher pass rates in the right ear (61% and 39% for right and left ears, respectively) in the study group, and in 1.75 dB greater TEOAE response amplitudes in the control group. The right-ear advantage was enhanced when the first tested ear was the right ear (76%). When the left ear was tested first, pass rates were comparable in both ears. The right-ear advantage in pass rates was similar in females versus males, but manifested in 1.5 dB higher response amplitudes in females compared with males, regardless of the tested ear and order of testing in both study and control groups. The study provides further evidence for the functional lateralization of the auditory system at the cochlear level already apparent soon after birth in both males and females. While order of testing plays a significant role in the asymmetry in pass rates, the innate right-ear advantage seems to be a more dominant contributor. PMID:27927982

  18. 40 CFR 211.206-1 - Real ear method.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Real ear method. 211.206-1 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.206-1 Real ear method. (a) The value of sound... “Method for the Measurement of Real-Ear Protection of Hearing Protectors and Physical Attenuation of...

  19. 40 CFR 211.206-1 - Real ear method.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Real ear method. 211.206-1 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.206-1 Real ear method. (a) The value of sound... “Method for the Measurement of Real-Ear Protection of Hearing Protectors and Physical Attenuation of...

  20. 40 CFR 211.206-1 - Real ear method.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Real ear method. 211.206-1 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.206-1 Real ear method. (a) The value of sound... “Method for the Measurement of Real-Ear Protection of Hearing Protectors and Physical Attenuation of...

  1. 40 CFR 211.206-1 - Real ear method.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Real ear method. 211.206-1 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.206-1 Real ear method. (a) The value of sound... “Method for the Measurement of Real-Ear Protection of Hearing Protectors and Physical Attenuation of...

  2. 40 CFR 211.206-1 - Real ear method.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Real ear method. 211.206-1 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.206-1 Real ear method. (a) The value of sound... “Method for the Measurement of Real-Ear Protection of Hearing Protectors and Physical Attenuation of...

  3. Ear-body lift and a novel thrust generating mechanism revealed by the complex wake of brown long-eared bats (Plecotus auritus)

    NASA Astrophysics Data System (ADS)

    Johansson, L. Christoffer; Håkansson, Jonas; Jakobsen, Lasse; Hedenström, Anders

    2016-04-01

    Large ears enhance perception of echolocation and prey generated sounds in bats. However, external ears likely impair aerodynamic performance of bats compared to birds. But large ears may generate lift on their own, mitigating the negative effects. We studied flying brown long-eared bats, using high resolution, time resolved particle image velocimetry, to determine the aerodynamics of flying with large ears. We show that the ears and body generate lift at medium to cruising speeds (3-5 m/s), but at the cost of an interaction with the wing root vortices, likely reducing inner wing performance. We also propose that the bats use a novel wing pitch mechanism at the end of the upstroke generating thrust at low speeds, which should provide effective pitch and yaw control. In addition, the wing tip vortices show a distinct spiraling pattern. The tip vortex of the previous wingbeat remains into the next wingbeat and rotates together with a newly formed tip vortex. Several smaller vortices, related to changes in circulation around the wing also spiral the tip vortex. Our results thus show a new level of complexity in bat wakes and suggest large eared bats are less aerodynamically limited than previous wake studies have suggested.

  4. Structured box training improves stability of retraction while multitasking in colorectal surgery simulation.

    PubMed

    Kobiela, Jarek; Spychalski, Piotr; Łaski, Dariusz; Błażyńska-Spychalska, Agata; Łachiński, Andrzej J; Śledziński, Zbigniew; Hull, Tracy

    2018-09-01

    Laparoscopic colorectal surgery has an established role. The ability to multitask (use a retraction tool with one hand and navigate a laparoscopic camera with the other) is desired for efficient laparoscopic surgery. Surgical trainees must learn this skill to perform advanced laparoscopic tasks. The aim was to determine whether a box-training protocol improves the stability of retraction while multitasking in colorectal surgery simulation. Fifty-eight medical students were recruited to attend a basic laparoscopic box-training course. Ability to perform steady retraction with and without multitasking was measured initially and at the conclusion of the course. Before training, students demonstrated a decrease in performance while multitasking with a greater maximal exerted force, a greater range of force, and a greater standard deviation for traction and minimal exerted force, range of force and a greater standard deviation for countertraction. Statistically significant improvement (lower maximal exerted force and lower range of force) was observed for traction while multitasking after training. After the training, no statistically significant differences were found when the student performed a single task versus multitasking, both for traction and countertraction. A structured box-training curriculum improved the stability of retraction while multitasking in this colorectal surgery simulation. Although it did not improve stability of retraction as a single task, it did improve stability of retraction while multitasking. After training, this enables the trainee to retract as efficiently while operating the camera as they retract when only focusing on retraction as a single task. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Middle Ear Infection (Chronic Otitis Media) and Hearing Loss

    MedlinePlus

    ... You Middle Ear Infection (Chronic Otitis Media) and Hearing Loss Middle Ear Infection (Chronic Otitis Media) and ... loss. How does otitis media affect a child’s hearing? All children with middle ear infection or fluid ...

  6. Impedances of the ear estimated with intracochlear pressures in normal human temporal bones

    NASA Astrophysics Data System (ADS)

    Frear, Darcy; Guan, Xiying; Stieger, Christof; Nakajima, Hideko Heidi

    2018-05-01

    We have measured intracochlear pressures and velocities of stapes and round window (RW) evoked by air conduction (AC) stimulation in many fresh human cadaveric specimens. Our techniques have improved through the years to ensure reliable pressure sensor measurements in the scala vestibuli and scala tympani. Using these measurements, we have calculated impedances of the middle and inner ear (cochlear partition, RW, and physiological leakage impedance in scala vestibuli) to create a lumped element model. Our model simulates our data and allows us to understand the mechanisms involved in air-conducted sound transmission. In the future this model will be used as a tool to understand transmission mechanisms of various stimuli and to help create more sophisticated models of the ear.

  7. The Use of Temporoparietal Fascial Flap to Eliminate Wound Breakdown in Subtotal Petrosectomy for Chronic Discharging Ears.

    PubMed

    Yung, Matthew

    2016-03-01

    To find out if the use of the vascularized temporo-parietal fascial flap (TPFF) reduces postoperative infection or wound breakdown in subtotal petrosectomy for chronic discharging ears. A retrospective review on 26 subtotal petrosectomies with blind pit closures on chronic discharging ears performed by a single surgeon between 2000 and 2015 was performed. All patients had a minimum follow-up period of 6 months. Eleven mastoid cavities were obliterated with abdominal fat, and 15 cavities were obliterated with TPFF. There was no concomitant cochlear implant or middle ear implant. All postoperative wound infections or delay in wound healing were recorded into a database. The complication rates of the fat obliteration group were compared using Fisher's exact test with those for the TPFF obliteration group. In the fat obliteration group, 4 out of 11 patients had documented postoperative complications. Three had wound breakdown with exposure of the fat that required revision surgery. Another patient had postauricular abscess without the wound actually broken down. On the other hand, all the ears in the TPFF obliteration group (100%) were completely free of wound infection, wound breakdown, or any complication. The difference between the two groups was statistically significant (p = 0.022). Many authors have encountered postoperative infection or wound breakdown in subtotal petrosectomy with fat obliteration in the treatment of chronic otitis media. Using a richly vascularized temporo-temporal fascial flap to protect the blind pit closure in such patients reduces postoperative infection and wound breakdown.

  8. Using the Real-Ear-to-Coupler Difference within the American Academy of Audiology Pediatric Amplification Guideline: Protocols for Applying and Predicting Earmold RECDs.

    PubMed

    Moodie, Sheila; Pietrobon, Jonathan; Rall, Eileen; Lindley, George; Eiten, Leisha; Gordey, Dave; Davidson, Lisa; Moodie, K Shane; Bagatto, Marlene; Haluschak, Meredith Magathan; Folkeard, Paula; Scollie, Susan

    2016-03-01

    Real-ear-to-coupler difference (RECD) measurements are used for the purposes of estimating degree and configuration of hearing loss (in dB SPL ear canal) and predicting hearing aid output from coupler-based measures. Accurate measurements of hearing threshold, derivation of hearing aid fitting targets, and predictions of hearing aid output in the ear canal assume consistent matching of RECD coupling procedure (i.e., foam tip or earmold) with that used during assessment and in verification of the hearing aid fitting. When there is a mismatch between these coupling procedures, errors are introduced. The goal of this study was to quantify the systematic difference in measured RECD values obtained when using a foam tip versus an earmold with various tube lengths. Assuming that systematic errors exist, the second goal was to investigate the use of a foam tip to earmold correction for the purposes of improving fitting accuracy when mismatched RECD coupling conditions occur (e.g., foam tip at assessment, earmold at verification). Eighteen adults and 17 children (age range: 3-127 mo) participated in this study. Data were obtained using simulated ears of various volumes and earmold tubing lengths and from patients using their own earmolds. Derived RECD values based on simulated ear measurements were compared with RECD values obtained for adult and pediatric ears for foam tip and earmold coupling. Results indicate that differences between foam tip and earmold RECDs are consistent across test ears for adults and children which support the development of a correction between foam tip and earmold couplings for RECDs that can be applied across individuals. The foam tip to earmold correction values developed in this study can be used to provide improved estimations of earmold RECDs. This may support better accuracy in acoustic transforms related to transforming thresholds and/or hearing aid coupler responses to ear canal sound pressure level for the purposes of fitting behind-the-ear

  9. Three-Dimensional Analysis of the Ear Morphology.

    PubMed

    Modabber, Ali; Galster, Helmut; Peters, Florian; Möhlhenrich, Stephan Christian; Kniha, Kristian; Knobe, Matthias; Hölzle, Frank; Ghassemi, Alireza

    2018-06-01

    For surgical treatment of the face, detailed surgical planning is necessary to avoid later unaesthetic results. Most of the studies in the literature concentrate on the ears' anatomy during childhood and adolescence. Nearly no study evaluates the anatomy of ears of people aged 50 or older. It was our aim to measure and evaluate the ear's anatomy in Caucasians between the ages of 21 and 65. Three-dimensional scans of 240 volunteers were taken. The subjects were divided into groups of males and females and each of them into three groups by age (21-35, 36-50, 51-65). Landmarks were placed in these scans. Distances, relations and angles between them were recorded. The distance between the subaurale and superaurale significantly increases (p < 0.001) during the aging process in males and females. Also, the width of the ear, measured between the preaurale and postaurale, significantly increased (p = 0.007) with advancing age. When the length of the ear is divided into four parts by anatomical landmarks, it extended the most in the lower quadrant with increasing subject age. The ear of Caucasians does not stop changing its shape during adulthood. Even after the body has stopped growing, the ear still does. With the measured values in this study, it should be possible for the surgeon to plan the operation in advance and achieve satisfactory aesthetic outcomes. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  10. Inverse solution of ear-canal area function from reflectance

    PubMed Central

    Rasetshwane, Daniel M.; Neely, Stephen T.

    2011-01-01

    A number of acoustical applications require the transformation of acoustical quantities, such as impedance and pressure that are measured at the entrance of the ear canal, to quantities at the eardrum. This transformation often requires knowledge of the shape of the ear canal. Previous attempts to measure ear-canal area functions were either invasive, non-reproducible, or could only measure the area function up to a point mid-way along the canal. A method to determine the area function of the ear canal from measurements of acoustic impedance at the entrance of the ear canal is described. The method is based on a solution to the inverse problem in which measurements of impedance are used to calculate reflectance, which is then used to determine the area function of the canal. The mean ear-canal area function determined using this method is similar to mean ear-canal area functions measured by other researchers using different techniques. The advantage of the proposed method over previous methods is that it is non- invasive, fast, and reproducible. PMID:22225043

  11. Evidence for a Right-Ear Advantage in Newborn Hearing Screening Results.

    PubMed

    Ari-Even Roth, Daphne; Hildesheimer, Minka; Roziner, Ilan; Henkin, Yael

    2016-12-06

    The aim of the present study was to investigate the effect of ear asymmetry, order of testing, and gender on transient-evoked otoacoustic emission (TEOAE) pass rates and response levels in newborn hearing screening. The screening results of 879 newborns, of whom 387 (study group) passed screening successfully in only one ear in the first TEOAE screening, but passed screening successfully in both ears thereafter, and 492 (control group) who passed screening successfully in both ears in the first TEOAE, were retrospectively examined for pass rates and TEOAE characteristics. Results indicated a right-ear advantage, as manifested by significantly higher pass rates in the right ear (61% and 39% for right and left ears, respectively) in the study group, and in 1.75 dB greater TEOAE response amplitudes in the control group. The right-ear advantage was enhanced when the first tested ear was the right ear (76%). When the left ear was tested first, pass rates were comparable in both ears. The right-ear advantage in pass rates was similar in females versus males, but manifested in 1.5 dB higher response amplitudes in females compared with males, regardless of the tested ear and order of testing in both study and control groups. The study provides further evidence for the functional lateralization of the auditory system at the cochlear level already apparent soon after birth in both males and females. While order of testing plays a significant role in the asymmetry in pass rates, the innate right-ear advantage seems to be a more dominant contributor. © The Author(s) 2016.

  12. Increasing Safety of a Robotic System for Inner Ear Surgery Using Probabilistic Error Modeling Near Vital Anatomy

    PubMed Central

    Dillon, Neal P.; Siebold, Michael A.; Mitchell, Jason E.; Blachon, Gregoire S.; Balachandran, Ramya; Fitzpatrick, J. Michael; Webster, Robert J.

    2017-01-01

    Safe and effective planning for robotic surgery that involves cutting or ablation of tissue must consider all potential sources of error when determining how close the tool may come to vital anatomy. A pre-operative plan that does not adequately consider potential deviations from ideal system behavior may lead to patient injury. Conversely, a plan that is overly conservative may result in ineffective or incomplete performance of the task. Thus, enforcing simple, uniform-thickness safety margins around vital anatomy is insufficient in the presence of spatially varying, anisotropic error. Prior work has used registration error to determine a variable-thickness safety margin around vital structures that must be approached during mastoidectomy but ultimately preserved. In this paper, these methods are extended to incorporate image distortion and physical robot errors, including kinematic errors and deflections of the robot. These additional sources of error are discussed and stochastic models for a bone-attached robot for otologic surgery are developed. An algorithm for generating appropriate safety margins based on a desired probability of preserving the underlying anatomical structure is presented. Simulations are performed on a CT scan of a cadaver head and safety margins are calculated around several critical structures for planning of a robotic mastoidectomy. PMID:29200595

  13. Increasing safety of a robotic system for inner ear surgery using probabilistic error modeling near vital anatomy

    NASA Astrophysics Data System (ADS)

    Dillon, Neal P.; Siebold, Michael A.; Mitchell, Jason E.; Blachon, Gregoire S.; Balachandran, Ramya; Fitzpatrick, J. Michael; Webster, Robert J.

    2016-03-01

    Safe and effective planning for robotic surgery that involves cutting or ablation of tissue must consider all potential sources of error when determining how close the tool may come to vital anatomy. A pre-operative plan that does not adequately consider potential deviations from ideal system behavior may lead to patient injury. Conversely, a plan that is overly conservative may result in ineffective or incomplete performance of the task. Thus, enforcing simple, uniform-thickness safety margins around vital anatomy is insufficient in the presence of spatially varying, anisotropic error. Prior work has used registration error to determine a variable-thickness safety margin around vital structures that must be approached during mastoidectomy but ultimately preserved. In this paper, these methods are extended to incorporate image distortion and physical robot errors, including kinematic errors and deflections of the robot. These additional sources of error are discussed and stochastic models for a bone-attached robot for otologic surgery are developed. An algorithm for generating appropriate safety margins based on a desired probability of preserving the underlying anatomical structure is presented. Simulations are performed on a CT scan of a cadaver head and safety margins are calculated around several critical structures for planning of a robotic mastoidectomy.

  14. Physiological functioning of the ear and masking

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The physiological functions of the ear and the role masking plays in speech communication are examined. Topics under investigation include sound analysis of the ear, the aural reflex, and various types of noise masking.

  15. Diode Laser Ear Piercing: A Novel Technique.

    PubMed

    Suseela, Bibilash Babu; Babu, Preethitha; Chittoria, Ravi Kumar; Mohapatra, Devi Prasad

    2016-01-01

    Earlobe piercing is a common office room procedure done by a plastic surgeon. Various methods of ear piercing have been described. In this article, we describe a novel method of laser ear piercing using the diode laser. An 18-year-old female patient underwent an ear piercing using a diode laser with a power of 2.0 W in continuous mode after topical local anaesthetic and pre-cooling. The diode laser was fast, safe, easy to use and highly effective way of ear piercing. The advantages we noticed while using the diode laser over conventional methods were more precision, minimal trauma with less chances of hypertrophy and keloids, no bleeding with coagulation effect of laser, less time taken compared to conventional method and less chance of infection due to thermal heat effect of laser.

  16. Face and content validity of Xperience™ Team Trainer: bed-side assistant training simulator for robotic surgery.

    PubMed

    Sessa, Luca; Perrenot, Cyril; Xu, Song; Hubert, Jacques; Bresler, Laurent; Brunaud, Laurent; Perez, Manuela

    2018-03-01

    In robotic surgery, the coordination between the console-side surgeon and bed-side assistant is crucial, more than in standard surgery or laparoscopy where the surgical team works in close contact. Xperience™ Team Trainer (XTT) is a new optional component for the dv-Trainer ® platform and simulates the patient-side working environment. We present preliminary results for face, content, and the workload imposed regarding the use of the XTT virtual reality platform for the psychomotor and communication skills training of the bed-side assistant in robot-assisted surgery. Participants were categorized into "Beginners" and "Experts". They tested a series of exercises (Pick & Place Laparoscopic Demo, Pick & Place 2 and Team Match Board 1) and completed face validity questionnaires. "Experts" assessed content validity on another questionnaire. All the participants completed a NASA Task Load Index questionnaire to assess the workload imposed by XTT. Twenty-one consenting participants were included (12 "Beginners" and 9 "Experts"). XTT was shown to possess face and content validity, as evidenced by the rankings given on the simulator's ease of use and realism parameters and on the simulator's usefulness for training. Eight out of nine "Experts" judged the visualization of metrics after the exercises useful. However, face validity has shown some weaknesses regarding interactions and instruments. Reasonable workload parameters were registered. XTT demonstrated excellent face and content validity with acceptable workload parameters. XTT could become a useful tool for robotic surgery team training.

  17. Improving the performance of surgery-based clinical pathways: a simulation-optimization approach.

    PubMed

    Ozcan, Yasar A; Tànfani, Elena; Testi, Angela

    2017-03-01

    This paper aims to improve the performance of clinical processes using clinical pathways (CPs). The specific goal of this research is to develop a decision support tool, based on a simulation-optimization approach, which identify the proper adjustment and alignment of resources to achieve better performance for both the patients and the health-care facility. When multiple perspectives are present in a decision problem, critical issues arise and often require the balancing of goals. In our approach, meeting patients' clinical needs in a timely manner, and to avoid worsening of clinical conditions, we assess the level of appropriate resources. The simulation-optimization model seeks and evaluates alternative resource configurations aimed at balancing the two main objectives-meeting patient needs and optimal utilization of beds and operating rooms.Using primary data collected at a Department of Surgery of a public hospital located in Genoa, Italy. The simulation-optimization modelling approach in this study has been applied to evaluate the thyroid surgical treatment together with the other surgery-based CPs. The low rate of bed utilization and the long elective waiting lists of the specialty under study indicates that the wards were oversized while the operating room capacity was the bottleneck of the system. The model enables hospital managers determine which objective has to be given priority, as well as the corresponding opportunity costs.

  18. Magnetically driven middle ear ossicles for optical measurement of vibrations in an ear with opened tympanic membrane

    NASA Astrophysics Data System (ADS)

    Peacock, J.; von Unge, M.; Dirckx, J.

    2013-12-01

    Vibrations of the middle ear ossicles are easily measured by means of laser vibrometry. However, laser vibrometry requires free visual access to the object under investigation, and acquiring free visual access to the ossicles through the ear canal requires the removal of the tympanic membrane (TM), with the result that the ossicles can no longer be stimulated acoustically. To overcome this, we devised a new setup in which the ossicles can be driven magnetically. After measuring the response of the TM to an acoustic signal, we then remove it and attach a small magnet to the exposed manubrium (a part of the most lateral auditory ossicle, the malleus, which is normally attached to the TM). An electromagnetic excitation coil is then used to drive the magnet, and the output to the coil adjusted until the vibration of the manubrium, as measured by the vibrometer, matches that measured in response to the acoustic signal. Such a setup may have uses in research on middle ear mechanics, such as the measurement of nonlinearities in their response, as well as applications in the diagnosis of middle ear conditions such as the fixation of the ossicles by otosclerosis or in chronic otitis media. We describe our setup and discuss the viability of our method and its future clinical potential by presenting some measurements on an artificially fixated ear.

  19. 21 CFR 874.3540 - Prosthesis modification instrument for ossicular replacement surgery.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Prosthesis modification instrument for ossicular replacement surgery. 874.3540 Section 874.3540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3540 Prosthesis modification...

  20. 21 CFR 874.3540 - Prosthesis modification instrument for ossicular replacement surgery.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Prosthesis modification instrument for ossicular replacement surgery. 874.3540 Section 874.3540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3540 Prosthesis modification...

  1. 21 CFR 874.3540 - Prosthesis modification instrument for ossicular replacement surgery.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Prosthesis modification instrument for ossicular replacement surgery. 874.3540 Section 874.3540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3540 Prosthesis modification...

  2. 21 CFR 874.3540 - Prosthesis modification instrument for ossicular replacement surgery.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prosthesis modification instrument for ossicular replacement surgery. 874.3540 Section 874.3540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3540 Prosthesis modification...

  3. 21 CFR 874.3540 - Prosthesis modification instrument for ossicular replacement surgery.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prosthesis modification instrument for ossicular replacement surgery. 874.3540 Section 874.3540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3540 Prosthesis modification...

  4. Cauliflower Ear and Skin Infections among Wrestlers in Tehran

    PubMed Central

    Kordi, Ramin; Mansournai, Mohammad Ali; Nourian, Roh Allah; Wallace, W. Angus

    2007-01-01

    The purpose of the study was to describe the magnitude of the selected sports medicine problems (i.e. cauliflower ear and skin infections) among wrestlers in Tehran. A number of 411 wrestlers were randomly selected from wrestling clubs in Tehran employing cluster sample setting method. The participants were interviewed using a specially designed and validated questionnaire. Nearly half of the participants (44%) had “cauliflower ears”. Only 23% of these participants had received any kind of treatment for their acute ear haematomas that are known to result in “cauliflower ears”. The prevalence of reported hearing loss among participants with cauliflower ears (11.5%, 95%CI: 6.9 to 16.2) was significantly more than this prevalence among those participants without cauliflower ears (1.8%, 95%CI: 0.1 to 3.5) (p < 0.05). More than half of the participants (52%) had skin infection diagnosed by a physician during the previous year. This study has identified evidence of an increase in hearing loss as a possible side effect of either cauliflower ear or ear injury in wrestling in Iran. There has been an outbreak of ringworm and there is a significant potential for an outbreak of impetigo among wrestlers in Tehran. Key points Skin infections are prevalent among wrestlers in Tehran. Commonly wrestlers in Tehran continue to carry out wrestling training while affected by skin infections. Cauliflower ear ”is common among wrestlers in Tehran. More research is needed to investigate hearing loss as a possible side effect of either cauliflower ear or ear injury in wrestling in Iran. PMID:24198702

  5. Cardiovascular Surgery Residency Program: Training Coronary Anastomosis Using the Arroyo Simulator and UNIFESP Models.

    PubMed

    Maluf, Miguel Angel; Gomes, Walter José; Bras, Ademir Massarico; Araújo, Thiago Cavalcante Vila Nova de; Mota, André Lupp; Cardoso, Caio Cesar; Coutinho, Rafael Viana dos S

    2015-01-01

    Engage the UNIFESP Cardiovascular Surgery residents in coronary anastomosis, assess their skills and certify results, using the Arroyo Anastomosis Simulator and UNIFESP surgical models. First to 6th year residents attended a weekly program of technical training in coronary anastomosis, using 4 simulation models: 1. Arroyo simulator; 2. Dummy with a plastic heart; 3. Dummy with a bovine heart; and 4. Dummy with a beating pig heart. The assessment test was comprised of 10 items, using a scale from 1 to 5 points in each of them, creating a global score of 50 points maximum. The technical performance of the candidate showed improvement in all items, especially manual skill and technical progress, critical sense of the work performed, confidence in the procedure and reduction of the time needed to perform the anastomosis after 12 weeks practice. In response to the multiplicity of factors that currently influence the cardiovascular surgeon training, there have been combined efforts to reform the practices of surgical medical training. 1 - The four models of simulators offer a considerable contribution to the field of cardiovascular surgery, improving the skill and dexterity of the surgeon in training. 2 - Residents have shown interest in training and cooperate in the development of innovative procedures for surgical medical training in the art.

  6. Can you hear me now? Understanding vertebrate middle ear development

    PubMed Central

    Chapman, Susan Caroline

    2010-01-01

    The middle ear is a composite organ formed from all three germ layers and the neural crest. It provides the link between the outside world and the inner ear, where sound is transduced and routed to the brain for processing. Extensive classical and modern studies have described the complex morphology and origin of the middle ear. Non-mammalian vertebrates have a single ossicle, the columella. Mammals have three functionally equivalent ossicles, designated the malleus, incus and stapes. In this review, I focus on the role of genes known to function in the middle ear. Genetic studies are beginning to unravel the induction and patterning of the multiple middle ear elements including the tympanum, skeletal elements, the air-filled cavity, and the insertion point into the inner ear oval window. Future studies that elucidate the integrated spatio-temporal signaling mechanisms required to pattern the middle ear organ system are needed. The longer-term translational benefits of understanding normal and abnormal ear development will have a direct impact on human health outcomes. PMID:21196256

  7. Investigation of a broadband duct noise control system inspired by the middle ear mechanism

    NASA Astrophysics Data System (ADS)

    Wang, Chunqi; Huang, Lixi

    2012-08-01

    A new duct noise control device is introduced based on the mechanism of human middle ear which functions as a compact, broadband impedance transformer between the air motion in the outer ear and the liquid motion in the inner ear. The system consists of two rigid endplates, simulating the tympanic membrane and the stapes footplate, and they are connected by a single rigid rod, simulating the overall action of the ossicular chain. These three pieces are placed in a side-branch cavity, and the whole device is called an ossicular silencer. A specific configuration is investigated numerically with a two-dimensional finite element model. Results show that broadband noise attenuation can be achieved in the very low frequency regime. Typically, two or more resonance peaks are found and the transmission loss between two neighbouring peaks is maintained at a high level. The cavity length is found to be the most crucial parameter that determines the effective frequency range of the ossicular silencer. The total cavity volume, which is a major controlling factor in most existing noise control devices, becomes less influential. The fluid medium in the enclosed cavity mainly acts like an added mass, while its stiffness effect is negligible. Simplified plane wave analysis is also conducted to reveal the mechanisms of the system resonances. The first resonance is identified as of the mass-spring system with mass contributions from both fluid and the plates, while the second one is of the Herschel-Quincke (HQ) tube resonance.

  8. Playing by Ear: Foundation or Frill?

    ERIC Educational Resources Information Center

    Woody, Robert H.

    2012-01-01

    Many people divide musicians into two types: those who can read music and those who play by ear. Formal music education tends to place great emphasis on producing musically literate performers but devotes much less attention to teaching students to make music without notation. Some would suggest that playing by ear is a specialized skill that is…

  9. Student perceptions of a simulation-based flipped classroom for the surgery clerkship: A mixed-methods study.

    PubMed

    Liebert, Cara A; Mazer, Laura; Bereknyei Merrell, Sylvia; Lin, Dana T; Lau, James N

    2016-09-01

    The flipped classroom, a blended learning paradigm that uses pre-session online videos reinforced with interactive sessions, has been proposed as an alternative to traditional lectures. This article investigates medical students' perceptions of a simulation-based, flipped classroom for the surgery clerkship and suggests best practices for implementation in this setting. A prospective cohort of students (n = 89), who were enrolled in the surgery clerkship during a 1-year period, was taught via a simulation-based, flipped classroom approach. Students completed an anonymous, end-of-clerkship survey regarding their perceptions of the curriculum. Quantitative analysis of Likert responses and qualitative analysis of narrative responses were performed. Students' perceptions of the curriculum were positive, with 90% rating it excellent or outstanding. The majority reported the curriculum should be continued (95%) and applied to other clerkships (84%). The component received most favorably by the students was the simulation-based skill sessions. Students rated the effectiveness of the Khan Academy-style videos the highest compared with other video formats (P < .001). Qualitative analysis identified 21 subthemes in 4 domains: general positive feedback, educational content, learning environment, and specific benefits to medical students. The students reported that the learning environment fostered accountability and self-directed learning. Specific perceived benefits included preparation for the clinical rotation and the National Board of Medical Examiners shelf exam, decreased class time, socialization with peers, and faculty interaction. Medical students' perceptions of a simulation-based, flipped classroom in the surgery clerkship were overwhelmingly positive. The flipped classroom approach can be applied successfully in a surgery clerkship setting and may offer additional benefits compared with traditional lecture-based curricula. Copyright © 2016 Elsevier Inc. All

  10. Continuous long-term measurements of the middle ear pressure in subjects without a history of ear disease.

    PubMed

    Tideholm, B; Carlborg, B; Jönsson, S; Bylander-Groth, A

    1998-06-01

    A new method was used for continuous measurement of the middle ear (ME) pressure during a 24-h period. In 10 subjects without a history of ear disease a small perforation was made through the tympanic membrane. A tight rubber stopper containing a small polyethylene tube was fitted into the external ear canal. Conventional tubal function tests were performed. The equipment was then carried by the subjects for 24 h of normal activity to monitor any slow or rapid dynamic pressure change in the ME. Body position was found to be the most important factor affecting ME pressure variation, during the 24-h continuous pressure measurements. A significant pressure rise occurred in the recumbent position in all but one subject. Few rapid pressure equilibrations were seen during the recordings, indicating few tubal openings. This implies that the pressure changes in the ME seen in this study were mainly the result of gas exchange over the mucosa. The investigation might be a base for reference when investigating different kinds of pathologic conditions in the ear.

  11. Simulation System for Training in Laparoscopic Surgery

    NASA Technical Reports Server (NTRS)

    Basdogan, Cagatay; Ho, Chih-Hao

    2003-01-01

    A computer-based simulation system creates a visual and haptic virtual environment for training a medical practitioner in laparoscopic surgery. Heretofore, it has been common practice to perform training in partial laparoscopic surgical procedures by use of a laparoscopic training box that encloses a pair of laparoscopic tools, objects to be manipulated by the tools, and an endoscopic video camera. However, the surgical procedures simulated by use of a training box are usually poor imitations of the actual ones. The present computer-based system improves training by presenting a more realistic simulated environment to the trainee. The system includes a computer monitor that displays a real-time image of the affected interior region of the patient, showing laparoscopic instruments interacting with organs and tissues, as would be viewed by use of an endoscopic video camera and displayed to a surgeon during a laparoscopic operation. The system also includes laparoscopic tools that the trainee manipulates while observing the image on the computer monitor (see figure). The instrumentation on the tools consists of (1) position and orientation sensors that provide input data for the simulation and (2) actuators that provide force feedback to simulate the contact forces between the tools and tissues. The simulation software includes components that model the geometries of surgical tools, components that model the geometries and physical behaviors of soft tissues, and components that detect collisions between them. Using the measured positions and orientations of the tools, the software detects whether they are in contact with tissues. In the event of contact, the deformations of the tissues and contact forces are computed by use of the geometric and physical models. The image on the computer screen shows tissues deformed accordingly, while the actuators apply the corresponding forces to the distal ends of the tools. For the purpose of demonstration, the system has been set

  12. Intravital imaging of a spheroid-based orthotopic model of melanoma in the mouse ear skin

    PubMed Central

    Chan, Keefe T.; Jones, Stephen W.; Brighton, Hailey E.; Bo, Tao; Cochran, Shelly D.; Sharpless, Norman E.; Bear, James E.

    2017-01-01

    Multiphoton microscopy is a powerful tool that enables the visualization of fluorescently tagged tumor cells and their stromal interactions within tissues in vivo. We have developed an orthotopic model of implanting multicellular melanoma tumor spheroids into the dermis of the mouse ear skin without the requirement for invasive surgery. Here, we demonstrate the utility of this approach to observe the primary tumor, single cell actin dynamics, and tumor-associated vasculature. These methods can be broadly applied to investigate an array of biological questions regarding tumor cell behavior in vivo. PMID:28748125

  13. Virtual reality in laparoscopic surgery.

    PubMed

    Uranüs, Selman; Yanik, Mustafa; Bretthauer, Georg

    2004-01-01

    Although the many advantages of laparoscopic surgery have made it an established technique, training in laparoscopic surgery posed problems not encountered in conventional surgical training. Virtual reality simulators open up new perspectives for training in laparoscopic surgery. Under realistic conditions in real time, trainees can tailor their sessions with the VR simulator to suit their needs and goals, and can repeat exercises as often as they wish. VR simulators reduce the number of experimental animals needed for training purposes and are suited to the pursuit of research in laparoscopic surgery.

  14. Anisotropic yield function capable of predicting eight ears

    NASA Astrophysics Data System (ADS)

    Yoon, J. H.; Cazacu, O.

    2011-08-01

    Deep drawing of a cylindrical cup from a rolled sheet is one of the typical forming operations where the effect of this anisotropy is most evident. Indeed, it is well documented in the literature that the number of ears and the shape of the earing pattern correlate with the r-values profile. For the strongly textured aluminum alloy AA 5042 (Numisheet Benchmark 2011), the experimental r-value distribution has two minima between the rolling and transverse direction data provided for this show that the r-value along the transverse direction (TD) is five times larger than the value corresponding to the rolling direction. Therefore, it is expected that there are more that the earing profile has more than four ears. The main objective of this paper is to assess whether a new form of CPB06ex2 yield function (Plunkett et al. (2008)) tailored for metals with no tension-compression asymmetry is capable of predicting more than four ears for this material.

  15. Inner ear abnormalities in patients with Goldenhar syndrome.

    PubMed

    Bisdas, Sotirios; Lenarz, Minoo; Lenarz, Thomas; Becker, Hartmut

    2005-05-01

    The objective of this study is to investigate the inner ear malformations in patients with Goldenhar syndrome and to hypothesize the potential embryopathogenesis of these malformations. Retrospective case review. Tertiary referral center. Fourteen patients with Goldenhar syndrome. Each patient underwent hearing tests and high-resolution computed tomography (CT) of the temporal bone. In six patients, magnetic resonance imaging of the temporal bone also was performed. Among the 14 patients with Goldenhar syndrome, 13 had outer and middle ear anomalies and 5 (36%) had inner ear malformations, including one case of common cavity. Our observations regarding inner ear anomalies in Goldenhar syndrome correlate with the reported cases in the literature and may help to hypothesize the embryological origin of these malformations, which can caused by an early developmental arrest in the fourth gestational week. Specialists evaluating patients with Goldenhar syndrome should be aware of the possibility of inner ear malformations, which could be diagnosed earlier with appropriate imaging studies.

  16. Ergonomics and human factors in endoscopic surgery: a comparison of manual vs telerobotic simulation systems.

    PubMed

    Lee, E C; Rafiq, A; Merrell, R; Ackerman, R; Dennerlein, J T

    2005-08-01

    Minimally invasive surgical techniques expose surgeons to a variety of occupational hazards that may promote musculoskeletal disorders. Telerobotic systems for minimally invasive surgery may help to reduce these stressors. The objective of this study was to compare manual and telerobotic endoscopic surgery in terms of postural and mental stress. Thirteen participants with no experience as primary surgeons in endoscopic surgery performed a set of simulated surgical tasks using two different techniques--a telerobotic master--slave system and a manual endoscopic surgery system. The tasks consisted of passing a soft spherical object through a series of parallel rings, suturing along a line 5-cm long, running a 32-in ribbon, and cannulation. The Job Strain Index (JSI) and Rapid Upper Limb Assessment (RULA) were used to quantify upper extremity exposure to postural and force risk factors. Task duration was quantified in seconds. A questionnaire provided measures of the participants' intuitiveness and mental stress. The JSI and RULA scores for all four tasks were significantly lower for the telerobotic technique than for the manual one. Task duration was significantly longer for telerobotic than for manual tasks. Participants reported that the telerobotic technique was as intuitive as, and no more stressful than, the manual technique. Given identical tasks, the time to completion is longer using the telerobotic technique than its manual counterpart. For the given simulated tasks in the laboratory setting, the better scores for the upper extremity postural analysis indicate that telerobotic surgery provides a more comfortable environment for the surgeon without any additional mental stress.

  17. Ear infection - acute

    MedlinePlus

    ... more than 6 children) Changes in altitude or climate Cold climate Exposure to smoke Family history of ear infections ... Clinical Assistant Professor of Pediatrics, University of Washington School of Medicine, Seattle, WA. Internal review and update ...

  18. Continuous 24-hour measurement of middle ear pressure.

    PubMed

    Tideholm, B; Jönsson, S; Carlborg, B; Welinder, R; Grenner, J

    1996-07-01

    A new method was developed for continuous measurement of the middle ear pressure during a 24-h period. The equipment consisted of a piezo-electric pressure device and a digital memory. To allow continuous pressure recordings during normal every-day activities the equipment was made light and portable. The measurement accuracy of the equipment as well as the base-line and temperature stability were tested and found to meet to our requirements satisfactorily. In 4 volunteers with different middle ear conditions, a small perforation was made through the tympanic membrane. A rubber stopper containing a small polyethylene tube was fitted into the external ear canal. Tubal function tests were made to establish the equipment's ability to monitor fast pressure changes. The tests were well in accordance with other methods of direct pressure measurements. The equipment was carried by the volunteers for 24 h to monitor any slow or rapid dynamic pressure changes in the middle ear. Four continuous 24-h measurements are presented. The method was found to be suitable for valid measurements of dynamic pressure changes in the middle ear during normal every-day activities. It may become a useful instrument in the search for a better understanding of the development of chronic middle ear disease.

  19. Fgf8 and Fgf3 are required for zebrafish ear placode induction, maintenance and inner ear patterning.

    PubMed

    Léger, Sophie; Brand, Michael

    2002-11-01

    The vertebrate inner ear develops from initially 'simple' ectodermal placode and vesicle stages into the complex three-dimensional structure which is necessary for the senses of hearing and equilibrium. Although the main morphological events in vertebrate inner ear development are known, the genetic mechanisms controlling them are scarcely understood. Previous studies have suggested that the otic placode is induced by signals from the chordamesoderm and the hindbrain, notably by fibroblast growth factors (Fgfs) and Wnt proteins. Here we study the role of Fgf8 as a bona-fide hindbrain-derived signal that acts in conjunction with Fgf3 during placode induction, maintenance and otic vesicle patterning. Acerebellar (ace) is a mutant in the fgf8 gene that results in a non-functional Fgf8 product. Homozygous mutants for acerebellar (ace) have smaller ears that typically have only one otolith, abnormal semi-circular canals, and behavioral defects. Using gene expression markers for the otic placode, we find that ace/fgf8 and Fgf-signaling are required for normal otic placode formation and maintenance. Conversely, misexpression of fgf8 or Fgf8-coated beads implanted into the vicinity of the otic placode can increase ear size and marker gene expression, although competence to respond to the induction appears restricted. Cell transplantation experiments and expression analysis suggest that Fgf8 is required in the hindbrain in the rhombomere 4-6 area to restore normal placode development in ace mutants, in close neighbourhood to the forming placode, but not in mesodermal tissues. Fgf3 and Fgf8 are expressed in hindbrain rhombomere 4 during the stages that are critical for placode induction. Joint inactivation of Fgf3 and Fgf8 by mutation or antisense-morpholino injection causes failure of placode formation and results in ear-less embryos, mimicking the phenotype we observe after pharmacological inhibition of Fgf-signaling. Fgf8 and Fgf3 together therefore act during induction

  20. Morphological Variations and Biometrics of Ear: An Aid to Personal Identification.

    PubMed

    Verma, Pradhuman; Sandhu, Harpreet Kaur; Verma, Kanika Gupta; Goyal, Sharry; Sudan, Madhu; Ladgotra, Amit

    2016-05-01

    The morphological characteristics and dimensions of external ear vary in different human ethnic races which can be utilized in forensics for personal identification of living or deceased. To determine uniqueness of morphological and biometric variations of both ears for individualization among North East (NE) and North West (NW) subpopulation of India. The study was conducted on randomly selected 80 students, 40 from each subgroup. Nine ear parameters were recorded twice using digital Vernier's caliper by single investigator and two indices (Ear Index and Lobule Index) were calculated for both the ears. Morphological ear shapes and lobule attachment were also noted. Pearson's coefficient correlation test was performed on cross-tabulations to evaluate significant relationship between different variables. Of the total 35% free and 65% attached ear lobes were noted in both population groups. Oval ear shape was most commonly noted followed by triangular, rectangular and round in both populations. On comparing anthropometric measurements of ears in two populations it was found that except the tragus length and lobule index all other values were noted more in NW population. No statistical difference was found in ear and lobular indices of males and females although the left ear index and lobule index were found to be higher than right in both populations except in NW females where right lobule index was recorded more than left. The results obtained can be used in anthropological and forensic sciences for the inclusion and exclusion of persons for identification on the basis of ear variations.