Science.gov

Sample records for early detection systems

  1. Early Forest Fire Detection Using Radio-Acoustic Sounding System

    PubMed Central

    Sahin, Yasar Guneri; Ince, Turker

    2009-01-01

    Automated early fire detection systems have recently received a significant amount of attention due to their importance in protecting the global environment. Some emergent technologies such as ground-based, satellite-based remote sensing and distributed sensor networks systems have been used to detect forest fires in the early stages. In this study, a radio-acoustic sounding system with fine space and time resolution capabilities for continuous monitoring and early detection of forest fires is proposed. Simulations show that remote thermal mapping of a particular forest region by the proposed system could be a potential solution to the problem of early detection of forest fires. PMID:22573967

  2. Development of an assisting detection system for early infarct diagnosis

    SciT

    Sim, K. S.; Nia, M. E.; Ee, C. S.

    2015-04-24

    In this paper, a detection assisting system for early infarct detection is developed. This new developed method is used to assist the medical practitioners to diagnose infarct from computed tomography images of brain. Using this assisting system, the infarct could be diagnosed at earlier stages. The non-contrast computed tomography (NCCT) brain images are the data set used for this system. Detection module extracts the pixel data from NCCT brain images, and produces the colourized version of images. The proposed method showed great potential in detecting infarct, and helps medical practitioners to make earlier and better diagnoses.

  3. Automated System for Early Breast Cancer Detection in Mammograms

    NASA Technical Reports Server (NTRS)

    Bankman, Isaac N.; Kim, Dong W.; Christens-Barry, William A.; Weinberg, Irving N.; Gatewood, Olga B.; Brody, William R.

    1993-01-01

    The increasing demand on mammographic screening for early breast cancer detection, and the subtlety of early breast cancer signs on mammograms, suggest an automated image processing system that can serve as a diagnostic aid in radiology clinics. We present a fully automated algorithm for detecting clusters of microcalcifications that are the most common signs of early, potentially curable breast cancer. By using the contour map of the mammogram, the algorithm circumvents some of the difficulties encountered with standard image processing methods. The clinical implementation of an automated instrument based on this algorithm is also discussed.

  4. A Simple System for the Early Detection of Breast Cancer

    DTIC Science & Technology

    2016-07-01

    AWARD NUMBER: W81XWH-14-1-0231 TITLE: A Simple System for Early Detection of Breast Cancer PRINCIPAL INVESTIGATOR: Stephen Johnston CONTRACTING...ADDRESS. 1. REPORT DATE July 2016 2. REPORT TYPE Annual 3. DATES COVERED 1Jul2015 - 30Jun2016 4. TITLE AND SUBTITLE A Simple System for the Early...Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18 W81XWH-14-1-0231 Abstract: We invented the immunosignature technology (IMS) as a simple , universal

  5. Signature-forecasting and early outbreak detection system

    PubMed Central

    Naumova, Elena N.; MacNeill, Ian B.

    2008-01-01

    SUMMARY Daily disease monitoring via a public health surveillance system provides valuable information on population risks. Efficient statistical tools for early detection of rapid changes in the disease incidence are a must for modern surveillance. The need for statistical tools for early detection of outbreaks that are not based on historical information is apparent. A system is discussed for monitoring cases of infections with a view to early detection of outbreaks and to forecasting the extent of detected outbreaks. We propose a set of adaptive algorithms for early outbreak detection that does not rely on extensive historical recording. We also include knowledge of infection disease epidemiology into forecasts. To demonstrate this system we use data from the largest water-borne outbreak of cryptosporidiosis, which occurred in Milwaukee in 1993. Historical data are smoothed using a loess-type smoother. Upon receipt of a new datum, the smoothing is updated and estimates are made of the first two derivatives of the smooth curve, and these are used for near-term forecasting. Recent data and the near-term forecasts are used to compute a color-coded warning index, which quantify the level of concern. The algorithms for computing the warning index have been designed to balance Type I errors (false prediction of an epidemic) and Type II errors (failure to correctly predict an epidemic). If the warning index signals a sufficiently high probability of an epidemic, then a forecast of the possible size of the outbreak is made. This longer term forecast is made by fitting a ‘signature’ curve to the available data. The effectiveness of the forecast depends upon the extent to which the signature curve captures the shape of outbreaks of the infection under consideration. PMID:18716671

  6. Video comparator system for early detection of cutaneous malignant melanoma

    NASA Astrophysics Data System (ADS)

    Craine, Eric R.; Craine, Brian L.

    1992-05-01

    The recognized incidence of cutaneous malignant melanoma in the United States is now rising faster than any other cancer, increasing by 83% from 1980 to 1987. Recent revelations that depletion of the earth's ozone layer is accelerating at a more rapid rate than previously believed can only exacerbate current projections for the increased incidence of this deadly disease. Because there is no good treatment for metastatic melanoma even small cancers often prove fatal if not detected early. Melanoma allowed to invade the subcutaneous tissue is associated with a five-year survival rate of only 44%. Ironically, few cancers provide a greater opportunity for early discovery and cure. Cutaneous melanoma is not only located where it is readily observed, but typically undergoes a `radial growth' phase prior to metastasis. During this phase the net growth is superficial and circumferential, gradually increasing the area of the lesion and changing its coloration. Screening measures for the early detection of melanoma must concentrate on two primary tasks: (1) detection of lesion changes indicative of the radial growth stage of malignancy and (2) alerting the patient and physician to the existence of a new or changed lesion on the skin. To accomplish these goals we have experimented with the applicability of a microcomputer based video imaging system which stores an image archive of historical reference images for each patient. With the acquisition of new images of the patient, easily registered with the archival images through a technique we have developed we are able to perform a blink comparison of the image pairs. This technique appears to be far more effective than currently used techniques for detecting changed lesions on a comprehensive basis.

  7. Deep Recurrent Neural Networks for seizure detection and early seizure detection systems

    SciT

    Talathi, S. S.

    Epilepsy is common neurological diseases, affecting about 0.6-0.8 % of world population. Epileptic patients suffer from chronic unprovoked seizures, which can result in broad spectrum of debilitating medical and social consequences. Since seizures, in general, occur infrequently and are unpredictable, automated seizure detection systems are recommended to screen for seizures during long-term electroencephalogram (EEG) recordings. In addition, systems for early seizure detection can lead to the development of new types of intervention systems that are designed to control or shorten the duration of seizure events. In this article, we investigate the utility of recurrent neural networks (RNNs) in designing seizuremore » detection and early seizure detection systems. We propose a deep learning framework via the use of Gated Recurrent Unit (GRU) RNNs for seizure detection. We use publicly available data in order to evaluate our method and demonstrate very promising evaluation results with overall accuracy close to 100 %. We also systematically investigate the application of our method for early seizure warning systems. Our method can detect about 98% of seizure events within the first 5 seconds of the overall epileptic seizure duration.« less

  8. Dual-mode microwave system to enhance early detection of cancer

    NASA Technical Reports Server (NTRS)

    Carr, K. L.; El-Mahdi, A. M.; Shaeffer, J.

    1981-01-01

    A dual-mode microwave system has been developed that will permit early detection of cancer. The system combines the use of the passive microwave radiometer with an active transmitter. The active transmitter will provide localized heating to enhance early detection by taking advantage of the differential heating (i.e., tumor temperature with respect to surrounding tissue) associated with the thermal characteristics of tumors.

  9. Stationary Digital Tomosynthesis System for Early Detection of Breast Tumors

    DTIC Science & Technology

    2011-05-01

    selenium flat panel detector. Proc. SPIE 2005. 5745: p. 529-540 4. Kopans, D.B., Breast Imaging. 2 ed. 1997, New York Lippincott Williams and...same. 2005. 8. M. Bissonnette, et al. Digital breast tomosynthesis using an amorphous selenium flat panel detector. in Medical Imaging 2005...tomosynthesis system with selenium based flat panel detector. Proc of SPIE, Physics of Medical Imaging, 2005. 5745. 12

  10. Stationary Digital Tomosynthesis System for Early Detection of Breast Tumors

    DTIC Science & Technology

    2012-05-01

    Vol. 5745. 2005. 14. Y. Zhang, et al., A comparative study of limited-angle cone-beam reconstruction methods 505 for breast tomosynthesis. Med...opening angl em integratio designed line nia Dimension determine the try calibration th the detector ain is sent fro between XC urce not fou here...screening mammography. AJR, 2007. 189: p. 616. 12. P. Baldelli, et al., A prototype of a quasi-monochromatic system for mammography applications . Phys

  11. A Context-Aware EEG Headset System for Early Detection of Driver Drowsiness.

    PubMed

    Li, Gang; Chung, Wan-Young

    2015-08-21

    Driver drowsiness is a major cause of mortality in traffic accidents worldwide. Electroencephalographic (EEG) signal, which reflects the brain activities, is more directly related to drowsiness. Thus, many Brain-Machine-Interface (BMI) systems have been proposed to detect driver drowsiness. However, detecting driver drowsiness at its early stage poses a major practical hurdle when using existing BMI systems. This study proposes a context-aware BMI system aimed to detect driver drowsiness at its early stage by enriching the EEG data with the intensity of head-movements. The proposed system is carefully designed for low-power consumption with on-chip feature extraction and low energy Bluetooth connection. Also, the proposed system is implemented using JAVA programming language as a mobile application for on-line analysis. In total, 266 datasets obtained from six subjects who participated in a one-hour monotonous driving simulation experiment were used to evaluate this system. According to a video-based reference, the proposed system obtained an overall detection accuracy of 82.71% for classifying alert and slightly drowsy events by using EEG data alone and 96.24% by using the hybrid data of head-movement and EEG. These results indicate that the combination of EEG data and head-movement contextual information constitutes a robust solution for the early detection of driver drowsiness.

  12. A Context-Aware EEG Headset System for Early Detection of Driver Drowsiness

    PubMed Central

    Li, Gang; Chung, Wan-Young

    2015-01-01

    Driver drowsiness is a major cause of mortality in traffic accidents worldwide. Electroencephalographic (EEG) signal, which reflects the brain activities, is more directly related to drowsiness. Thus, many Brain-Machine-Interface (BMI) systems have been proposed to detect driver drowsiness. However, detecting driver drowsiness at its early stage poses a major practical hurdle when using existing BMI systems. This study proposes a context-aware BMI system aimed to detect driver drowsiness at its early stage by enriching the EEG data with the intensity of head-movements. The proposed system is carefully designed for low-power consumption with on-chip feature extraction and low energy Bluetooth connection. Also, the proposed system is implemented using JAVA programming language as a mobile application for on-line analysis. In total, 266 datasets obtained from six subjects who participated in a one-hour monotonous driving simulation experiment were used to evaluate this system. According to a video-based reference, the proposed system obtained an overall detection accuracy of 82.71% for classifying alert and slightly drowsy events by using EEG data alone and 96.24% by using the hybrid data of head-movement and EEG. These results indicate that the combination of EEG data and head-movement contextual information constitutes a robust solution for the early detection of driver drowsiness. PMID:26308002

  13. Topological characterization and early detection of bifurcations and chaos in complex systems using persistent homology.

    PubMed

    Mittal, Khushboo; Gupta, Shalabh

    2017-05-01

    Early detection of bifurcations and chaos and understanding their topological characteristics are essential for safe and reliable operation of various electrical, chemical, physical, and industrial processes. However, the presence of non-linearity and high-dimensionality in system behavior makes this analysis a challenging task. The existing methods for dynamical system analysis provide useful tools for anomaly detection (e.g., Bendixson-Dulac and Poincare-Bendixson criteria can detect the presence of limit cycles); however, they do not provide a detailed topological understanding about system evolution during bifurcations and chaos, such as the changes in the number of subcycles and their positions, lifetimes, and sizes. This paper addresses this research gap by using topological data analysis as a tool to study system evolution and develop a mathematical framework for detecting the topological changes in the underlying system using persistent homology. Using the proposed technique, topological features (e.g., number of relevant k-dimensional holes, etc.) are extracted from nonlinear time series data which are useful for deeper analysis of the system behavior and early detection of bifurcations and chaos. When applied to a Logistic map, a Duffing oscillator, and a real life Op-amp based Jerk circuit, these features are shown to accurately characterize the system dynamics and detect the onset of chaos.

  14. Missed, Misused, or Mismanaged: Improving Early Detection Systems to Optimize Child Outcomes

    ERIC Educational Resources Information Center

    Macy, Marisa; Marks, Kevin; Towle, Alexander

    2014-01-01

    Early detection efforts have been shown to vary greatly in practice, and there is a general lack of systematic accountability built into monitoring early detection effort impact. This article reviews current early detection practices and the drawbacks of these practices, with particular attention given to prevalent issues of mismeasurement,…

  15. Early Detection of Infection in Pigs through an Online Monitoring System.

    PubMed

    Martínez-Avilés, M; Fernández-Carrión, E; López García-Baones, J M; Sánchez-Vizcaíno, J M

    2017-04-01

    Late detection of emergency diseases causes significant economic losses for pig producers and governments. As the first signs of animal infection are usually fever and reduced motion that lead to reduced consumption of water and feed, we developed a novel smart system to monitor body temperature and motion in real time, facilitating the early detection of infectious diseases. In this study, carried out within the framework of the European Union research project Rapidia Field, we tested the smart system on 10 pigs experimentally infected with two doses of an attenuated strain of African swine fever. Biosensors and an accelerometer embedded in an eartag captured data before and after infection, and video cameras were used to monitor the animals 24 h per day. The results showed that in 8 of 9 cases, the monitoring system detected infection onset as an increase in body temperature and decrease in movement before or simultaneously with fever detection based on rectal temperature measurement, observation of clinical signs, the decrease in water consumption or positive qPCR detection of virus. In addition, this decrease in movement was reliably detected using automatic analysis of video images therefore providing an inexpensive alternative to direct motion measurement. The system can be set up to alert staff when high fever, reduced motion or both are detected in one or more animals. This system may be useful for monitoring sentinel herds in real time, considerably reducing the financial and logistical costs of periodic sampling and increasing the chances of early detection of infection. © 2015 Blackwell Verlag GmbH.

  16. Archeological treasures protection based on early forest wildfire multi-band imaging detection system

    NASA Astrophysics Data System (ADS)

    Gouverneur, B.; Verstockt, S.; Pauwels, E.; Han, J.; de Zeeuw, P. M.; Vermeiren, J.

    2012-10-01

    Various visible and infrared cameras have been tested for the early detection of wildfires to protect archeological treasures. This analysis was possible thanks to the EU Firesense project (FP7-244088). Although visible cameras are low cost and give good results during daytime for smoke detection, they fall short under bad visibility conditions. In order to improve the fire detection probability and reduce the false alarms, several infrared bands are tested ranging from the NIR to the LWIR. The SWIR and the LWIR band are helpful to locate the fire through smoke if there is a direct Line Of Sight. The Emphasis is also put on the physical and the electro-optical system modeling for forest fire detection at short and longer ranges. The fusion in three bands (Visible, SWIR, LWIR) is discussed at the pixel level for image enhancement and for fire detection.

  17. Developing Fluorescence Sensor Systems for Early Detection of Nitrification Events in Chloraminated Drinking Water Distribution Systems

    EPA Science Inventory

    Detection of nitrification events in chloraminated drinking water distribution systems remains an ongoing challenge for many drinking water utilities, including Dallas Water Utilities (DWU) and the City of Houston (CoH). Each year, these utilities experience nitrification events ...

  18. An opto-electronic joint detection system based on DSP aiming at early cervical cancer screening

    NASA Astrophysics Data System (ADS)

    Wang, Weiya; Jia, Mengyu; Gao, Feng; Yang, Lihong; Qu, Pengpeng; Zou, Changping; Liu, Pengxi; Zhao, Huijuan

    2015-02-01

    The cervical cancer screening at a pre-cancer stage is beneficial to reduce the mortality of women. An opto-electronic joint detection system based on DSP aiming at early cervical cancer screening is introduced in this paper. In this system, three electrodes alternately discharge to the cervical tissue and three light emitting diodes in different wavelengths alternately irradiate the cervical tissue. Then the relative optical reflectance and electrical voltage attenuation curve are obtained by optical and electrical detection, respectively. The system is based on DSP to attain the portable and cheap instrument. By adopting the relative reflectance and the voltage attenuation constant, the classification algorithm based on Support Vector Machine (SVM) discriminates abnormal cervical tissue from normal. We use particle swarm optimization to optimize the two key parameters of SVM, i.e. nuclear factor and cost factor. The clinical data were collected on 313 patients to build a clinical database of tissue responses under optical and electrical stimulations with the histopathologic examination as the gold standard. The classification result shows that the opto-electronic joint detection has higher total coincidence rate than separate optical detection or separate electrical detection. The sensitivity, specificity, and total coincidence rate increase with the increasing of sample numbers in the training set. The average total coincidence rate of the system can reach 85.1% compared with the histopathologic examination.

  19. Efficacy of light based detection systems for early detection of oral cancer and oral potentially malignant disorders: Systematic review.

    PubMed

    Nagi, R; Reddy-Kantharaj, Y-B; Rakesh, N; Janardhan-Reddy, S; Sahu, S

    2016-07-01

    Earlier detection of oral squamous cell carcinoma (OSCC) and oral potentially malignant disorders (OPMD) is essential for dental professionals to improve patient survival rates. The aim of this systematic review is to to evaluate the effectiveness of devices that utilise the principles of chemiluminescence and tissue autofluorescence as adjuncts in the detection of OSCC and OPMD. The electronic retrieval systems and databases searched for relevant articles were PubMed [MEDLINE] and Science direct. The search was for limited articles published in English or with an English abstract and articles published during the period from January 2005 to April 2014. Clinical trials utilized ViziLite, Microlux TM/DL and Visual Enhanced Light scope (VELscope) for early detection of OPMD and OSCC. Twenty primary studies published satisfied our criteria for selection - 10 utilised chemiluminescence and 10 tissue autofluorescence. Senstivity of Vizilite for detecting OSCC nad OPMD ranged from 77.1 % to 100% and specificity was low that ranged from 0% to 27.8%.Most have shown that chemiluminescence increases the brightness and margins of oral mucosal white lesions and thus assist in identification of mucosal lesions not considered under Conventional visual examination. However, it preferentially detects leukoplakia and may fail to spot red patches. Clinical trials demonstrated that sensitivity of VELscope in detecting malignancy and OPMD ranged from 22 % to 100 % and specificity ranged from 16 % to 100%. Most studies concluded that VELscope can help the experienced clinician to find oral precursor malignant lesions. But it couldnot differentiate between dysplasia and benign inflammatory conditions. Both devices are simple, non-invasive test of the oral mucosa but are suited for clinicians with sufficient experience and training. More clinical trials in future should be conducted to establish optical imaging as an efficacious adjunct tool in early diagnosis of OSCC and OPMD.

  20. A novel multimodal optical imaging system for early detection of oral cancer

    PubMed Central

    Malik, Bilal H.; Jabbour, Joey M.; Cheng, Shuna; Cuenca, Rodrigo; Cheng, Yi-Shing Lisa; Wright, John M.; Jo, Javier A.; Maitland, Kristen C.

    2015-01-01

    Objectives Several imaging techniques have been advocated as clinical adjuncts to improve identification of suspicious oral lesions. However, these have not yet shown superior sensitivity or specificity over conventional oral examination techniques. We developed a multimodal, multi-scale optical imaging system that combines macroscopic biochemical imaging of fluorescence lifetime imaging (FLIM) with subcellular morphologic imaging of reflectance confocal microscopy (RCM) for early detection of oral cancer. We tested our system on excised human oral tissues. Study Design A total of four tissue specimen were imaged. These specimens were diagnosed as one each: clinically normal, oral lichen planus, gingival hyperplasia, and superficially-invasive squamous cell carcinoma (SCC). The optical and fluorescence lifetime properties of each specimen were recorded. Results Both quantitative and qualitative differences between normal, benign and SCC lesions can be resolved with FLIM-RCM imaging. The results demonstrate that an integrated approach based on these two methods can potentially enable rapid screening and evaluation of large areas of oral epithelial tissue. Conclusions Early results from ongoing studies of imaging human oral cavity illustrate the synergistic combination of the two modalities. An adjunct device based on such optical characterization of oral mucosa can potentially be used to detect oral carcinogenesis in early stages. PMID:26725720

  1. Development of Early Warning System Using ALOS-2/PALSAR-2 Data to Detect and Prevent Deforestation

    NASA Astrophysics Data System (ADS)

    Hayashi, M.; Nagatani, I.; Watanabe, T.; Tadono, T.; Miyoshi, H.; Watanabe, M.; Koyama, C.; Shimada, M.; Ogawa, T.; Ishii, K.; Higashiuwatoko, T.; Miura, M.; Okonogi, H.; Adachi, K.; Morita, T.

    2017-12-01

    Satellite observation is an efficient method for monitoring deforestation, and a synthetic aperture radar (SAR) is useful especially in cloudy tropical forest regions. In this context, JICA and JAXA cooperate to operate the deforestation monitoring system acquired data by the Phased Array type L-band SAR-2 (PALSAR-2) onboard the Advanced Land Observing Satellite-2 (ALOS-2), which is named as "JICA-JAXA Forest Early Warning System in the Tropics" (JJ-FAST), and it have been released on November 2016. JJ-FAST detects deforestation areas, and provides their positional information for 77 countries, which is covering almost all tropical forests. It uses PALSAR-2 ScanSAR observation mode (wide-observation swath width) image, which is 50 m spatial resolution acquired at 1.5 months interval. The dark change areas compared with in two acquisitions by PALSAR-2 HV-polarization images are identified as deforestations in the system. We conducted field surveys to validate detection accuracy of the JJ-FAST in Peru (November and December, 2016), Botswana (April, 2017), and Gabon (July, 2017). As the results, 15 of 18 detected areas were correct deforestation areas, therefore user's accuracy could be confirmed as 83.3 % from limited number of the validation data. Erroneous detection areas were caused by seasonal change in agricultural land and open burning in grass land. For improvement of the accuracy, such areas must be excluded from the analysis by additional algorithms e.g. estimation of accurate masking for non-forested areas. Therefore, we are revising the forest map used for pre-processing step in the system. The JJ-FAST can be expected to contribute to monitor and reduce illegal deforestation activities in tropical forests.

  2. Breath analysis system for early detection of lung diseases based on multi-sensor array

    NASA Astrophysics Data System (ADS)

    Jeon, Jin-Young; Yu, Joon-Boo; Shin, Jeong-Suk; Byun, Hyung-Gi; Lim, Jeong-Ok

    2013-05-01

    Expiratory breath contains various VOCs(Volatile Organic Compounds) produced from the human. When a certain disease exists, the exhalation has specific VOCs which may be generated from diseases. Many researchers have been actively working to find different types of biomarkers which are characteristic for particular diseases. Research regarding the identification of specific diseases from exhalation is still in progress. The aim of this research is to implement early detection of lung disease such as lung cancer and COPD(Chronic Obstructive Pulmonary Disease), which was nominated on the 6th of domestic death rate in 2010, based on multi-sensor array system. The system has been used to acquire sampled expiratory gases data and PCA(Principle Component Analysis) technique was applied to analyze signals from multi-sensor array. Throughout the experimental trials, a clearly distinguishable difference between lung disease patients and healthy controls was found from the measurement and analysis of their respective expiratory gases.

  3. Bi-model processing for early detection of breast tumor in CAD system

    NASA Astrophysics Data System (ADS)

    Mughal, Bushra; Sharif, Muhammad; Muhammad, Nazeer

    2017-06-01

    Early screening of skeptical masses in mammograms may reduce mortality rate among women. This rate can be further reduced upon developing the computer-aided diagnosis system with decrease in false assumptions in medical informatics. This method highlights the early tumor detection in digitized mammograms. For improving the performance of this system, a novel bi-model processing algorithm is introduced. It divides the region of interest into two parts, the first one is called pre-segmented region (breast parenchyma) and other is the post-segmented region (suspicious region). This system follows the scheme of the preprocessing technique of contrast enhancement that can be utilized to segment and extract the desired feature of the given mammogram. In the next phase, a hybrid feature block is presented to show the effective performance of computer-aided diagnosis. In order to assess the effectiveness of the proposed method, a database provided by the society of mammographic images is tested. Our experimental outcomes on this database exhibit the usefulness and robustness of the proposed method.

  4. Prototype early warning system for heart disease detection using Android Application.

    PubMed

    Zennifa, Fadilla; Fitrilina; Kamil, Husnil; Iramina, Keiji

    2014-01-01

    Heart Disease affects approximately 70 million people worldwide where most people do not even know the symptoms. This research examines the prototype of early warning system for heart disease by android application. It aims to facilitate users to early detect heart disease which can be used independently. To build the application in android phone, variable centered intelligence rule system (VCIRS) as decision makers and pulse sensor - Arduino as heart rate detector were applied in this study. Moreover, in Arduino, the heart rate will become an input for symptoms in Android Application. The output of this system is the conclusion statement of users diagnosed with either coronary heart disease, hypertension heart disease, rheumatic heart disease or do not get any kind of heart disease. The result of diagnosis followed by analysis of the value of usage variable rate (VUR) rule usage rate (RUR) and node usage rate (NUR) that shows the value of the rule that will increase when the symptoms frequently appear. This application was compared with the medical analysis from 35 cases of heart disease and it showed concordance between diagnosis from android application and expert diagnosis of the doctors.

  5. Framework for evaluating public health surveillance systems for early detection of outbreaks: recommendations from the CDC Working Group.

    PubMed

    Buehler, James W; Hopkins, Richard S; Overhage, J Marc; Sosin, Daniel M; Tong, Van

    2004-05-07

    The threat of terrorism and high-profile disease outbreaks has drawn attention to public health surveillance systems for early detection of outbreaks. State and local health departments are enhancing existing surveillance systems and developing new systems to better detect outbreaks through public health surveillance. However, information is limited about the usefulness of surveillance systems for outbreak detection or the best ways to support this function. This report supplements previous guidelines for evaluating public health surveillance systems. Use of this framework is intended to improve decision-making regarding the implementation of surveillance for outbreak detection. Use of a standardized evaluation methodology, including description of system design and operation, also will enhance the exchange of information regarding methods to improve early detection of outbreaks. The framework directs particular attention to the measurement of timeliness and validity for outbreak detection. The evaluation framework is designed to support assessment and description of all surveillance approaches to early detection, whether through traditional disease reporting, specialized analytic routines for aberration detection, or surveillance using early indicators of disease outbreaks, such as syndromic surveillance.

  6. Method and system for early detection of incipient faults in electric motors

    DOEpatents

    Parlos, Alexander G; Kim, Kyusung

    2003-07-08

    A method and system for early detection of incipient faults in an electric motor are disclosed. First, current and voltage values for one or more phases of the electric motor are measured during motor operations. A set of current predictions is then determined via a neural network-based current predictor based on the measured voltage values and an estimate of motor speed values of the electric motor. Next, a set of residuals is generated by combining the set of current predictions with the measured current values. A set of fault indicators is subsequently computed from the set of residuals and the measured current values. Finally, a determination is made as to whether or not there is an incipient electrical, mechanical, and/or electromechanical fault occurring based on the comparison result of the set of fault indicators and a set of predetermined baseline values.

  7. Detection of buried targets using a new enhanced very early time electromagnetic (VETEM) prototype system

    Cui, T.J.; Chew, W.C.; Aydiner, A.A.; Wright, D.L.; Smith, D.V.

    2001-01-01

    In this paper, numerical simulations of a new enhanced very early time electromagnetic (VETEM) prototype system are presented, where a horizontal transmitting loop and two horizontal receiving loops are used to detect buried targets, in which three loops share the same axis and the transmitter is located at the center of receivers. In the new VETEM system, the difference of signals from two receivers is taken to eliminate strong direct-signals from the transmitter and background clutter and furthermore to obtain a better SNR for buried targets. Because strong coupling exists between the transmitter and receivers, accurate analysis of the three-loop antenna system is required, for which a loop-tree basis function method has been utilized to overcome the low-frequency breakdown problem. In the analysis of scattering problem from buried targets, a conjugate gradient (CG) method with fast Fourier transform (FFT) is applied to solve the electric field integral equation. However, the convergence of such CG-FFT algorithm is extremely slow at very low frequencies. In order to increase the convergence rate, a frequency-hopping approach has been used. Finally, the primary, coupling, reflected, and scattered magnetic fields are evaluated at receiving loops to calculate the output electric current. Numerous simulation results are given to interpret the new VETEM system. Comparing with other single-transmitter-receiver systems, the new VETEM has better SNR and ability to reduce the clutter.

  8. Dynamic MRI-based computer aided diagnostic systems for early detection of kidney transplant rejection: A survey

    NASA Astrophysics Data System (ADS)

    Mostapha, Mahmoud; Khalifa, Fahmi; Alansary, Amir; Soliman, Ahmed; Gimel'farb, Georgy; El-Baz, Ayman

    2013-10-01

    Early detection of renal transplant rejection is important to implement appropriate medical and immune therapy in patients with transplanted kidneys. In literature, a large number of computer-aided diagnostic (CAD) systems using different image modalities, such as ultrasound (US), magnetic resonance imaging (MRI), computed tomography (CT), and radionuclide imaging, have been proposed for early detection of kidney diseases. A typical CAD system for kidney diagnosis consists of a set of processing steps including: motion correction, segmentation of the kidney and/or its internal structures (e.g., cortex, medulla), construction of agent kinetic curves, functional parameter estimation, diagnosis, and assessment of the kidney status. In this paper, we survey the current state-of-the-art CAD systems that have been developed for kidney disease diagnosis using dynamic MRI. In addition, the paper addresses several challenges that researchers face in developing efficient, fast and reliable CAD systems for the early detection of kidney diseases.

  9. Time resolved optical system for an early detection of prostate tumor

    NASA Astrophysics Data System (ADS)

    Hervé, Lionel; Laidevant, Aurélie; Debourdeau, Mathieu; Boutet, Jérôme; Dinten, Jean-Marc

    2011-02-01

    We developed an endorectal time-resolved optical probe aiming at an early detection of prostate tumors targeted by fluorescent markers. Optical fibers are embedded inside a clinical available ultrasound endorectal probe. Excitation light is driven sequentially from a femtosecond laser (775 nm) into 6 source fibers. 4 detection fibers collect the medium responses at the excitation and fluorescence wavelength (850 nm) by the mean of 4 photomultipliers associated with a 4 channel time-correlated single photon counting card. We also developed the method to process the experimental data. This involves the numerical computation of the forward model, the creation of robust features which are automatically correctly from numerous experimental possible biases and the reconstruction of the inclusion by using the intensity and mean time of these features. To evaluate our system performance, we acquired measurements of a 40 μL ICG inclusion (10 μmol.L-1) at various lateral and depth locations in a phantom. Analysis of results showed we correctly reconstructed the fluorophore for the lateral positions (16 mm range) and for a distance to the probe going up to 1.5 cm. Precision of localization was found to be around 1 mm which complies well with precision specifications needed for the clinical application.

  10. An Architecture for Automated Fire Detection Early Warning System Based on Geoprocessing Service Composition

    NASA Astrophysics Data System (ADS)

    Samadzadegan, F.; Saber, M.; Zahmatkesh, H.; Joze Ghazi Khanlou, H.

    2013-09-01

    Rapidly discovering, sharing, integrating and applying geospatial information are key issues in the domain of emergency response and disaster management. Due to the distributed nature of data and processing resources in disaster management, utilizing a Service Oriented Architecture (SOA) to take advantages of workflow of services provides an efficient, flexible and reliable implementations to encounter different hazardous situation. The implementation specification of the Web Processing Service (WPS) has guided geospatial data processing in a Service Oriented Architecture (SOA) platform to become a widely accepted solution for processing remotely sensed data on the web. This paper presents an architecture design based on OGC web services for automated workflow for acquisition, processing remotely sensed data, detecting fire and sending notifications to the authorities. A basic architecture and its building blocks for an automated fire detection early warning system are represented using web-based processing of remote sensing imageries utilizing MODIS data. A composition of WPS processes is proposed as a WPS service to extract fire events from MODIS data. Subsequently, the paper highlights the role of WPS as a middleware interface in the domain of geospatial web service technology that can be used to invoke a large variety of geoprocessing operations and chaining of other web services as an engine of composition. The applicability of proposed architecture by a real world fire event detection and notification use case is evaluated. A GeoPortal client with open-source software was developed to manage data, metadata, processes, and authorities. Investigating feasibility and benefits of proposed framework shows that this framework can be used for wide area of geospatial applications specially disaster management and environmental monitoring.

  11. Costs of early detection systems for epidemic malaria in highland areas of Kenya and Uganda.

    PubMed

    Mueller, Dirk H; Abeku, Tarekegn A; Okia, Michael; Rapuoda, Beth; Cox, Jonathan

    2009-01-16

    Malaria epidemics cause substantial morbidity and mortality in highland areas of Africa. The costs of detecting and controlling these epidemics have not been explored adequately in the past. This study presents the costs of establishing and running an early detection system (EDS) for epidemic malaria in four districts in the highlands of Kenya and Uganda. An economic costing was carried out from the health service provider's perspective in both countries. Staff time for data entry and processing, as well as supervising and coordinating EDS activities at district and national levels was recorded and associated opportunity costs estimated. A threshold analysis was carried out to determine the number of DALYs or deaths that would need to be averted in order for the EDS to be considered cost-effective. The total costs of the EDS per district per year ranged between US$ 14,439 and 15,512. Salaries were identified as major cost-drivers, although their relative contribution to overall costs varied by country. Costs of relaying surveillance data between facilities and district offices (typically by hand) were also substantial. Data from Uganda indicated that 4% or more of overall costs could potentially be saved by switching to data transfer via mobile phones. Based on commonly used thresholds, 96 DALYs in Uganda and 103 DALYs in Kenya would need to be averted annually in each district for the EDS to be considered cost-effective. Results from this analysis suggest that EDS are likely to be cost-effective. Further studies that include the costs and effects of the health systems' reaction prompted by EDS will need to be undertaken in order to obtain comprehensive cost-effectiveness estimates.

  12. Costs of early detection systems for epidemic malaria in highland areas of Kenya and Uganda

    PubMed Central

    Mueller, Dirk H; Abeku, Tarekegn A; Okia, Michael; Rapuoda, Beth; Cox, Jonathan

    2009-01-01

    Background Malaria epidemics cause substantial morbidity and mortality in highland areas of Africa. The costs of detecting and controlling these epidemics have not been explored adequately in the past. This study presents the costs of establishing and running an early detection system (EDS) for epidemic malaria in four districts in the highlands of Kenya and Uganda. Methods An economic costing was carried out from the health service provider's perspective in both countries. Staff time for data entry and processing, as well as supervising and coordinating EDS activities at district and national levels was recorded and associated opportunity costs estimated. A threshold analysis was carried out to determine the number of DALYs or deaths that would need to be averted in order for the EDS to be considered cost-effective. Results The total costs of the EDS per district per year ranged between US$ 14,439 and 15,512. Salaries were identified as major cost-drivers, although their relative contribution to overall costs varied by country. Costs of relaying surveillance data between facilities and district offices (typically by hand) were also substantial. Data from Uganda indicated that 4% or more of overall costs could potentially be saved by switching to data transfer via mobile phones. Based on commonly used thresholds, 96 DALYs in Uganda and 103 DALYs in Kenya would need to be averted annually in each district for the EDS to be considered cost-effective. Conclusion Results from this analysis suggest that EDS are likely to be cost-effective. Further studies that include the costs and effects of the health systems' reaction prompted by EDS will need to be undertaken in order to obtain comprehensive cost-effectiveness estimates. PMID:19149878

  13. Early detection of West Nile virus in France: quantitative assessment of syndromic surveillance system using nervous signs in horses.

    PubMed

    Faverjon, C; Vial, F; Andersson, M G; Lecollinet, S; Leblond, A

    2017-04-01

    West Nile virus (WNV) is a growing public health concern in Europe and there is a need to develop more efficient early detection systems. Nervous signs in horses are considered to be an early indicator of WNV and, using them in a syndromic surveillance system, might be relevant. In our study, we assessed whether or not data collected by the passive French surveillance system for the surveillance of equine diseases can be used routinely for the detection of WNV. We tested several pre-processing methods and detection algorithms based on regression. We evaluated system performances using simulated and authentic data and compared them to those of the surveillance system currently in place. Our results show that the current detection algorithm provided similar performances to those tested using simulated and real data. However, regression models can be easily and better adapted to surveillance objectives. The detection performances obtained were compatible with the early detection of WNV outbreaks in France (i.e. sensitivity 98%, specificity >94%, timeliness 2·5 weeks and around four false alarms per year) but further work is needed to determine the most suitable alarm threshold for WNV surveillance in France using cost-efficiency analysis.

  14. Early detection of lung cancer recurrence after stereotactic ablative radiation therapy: radiomics system design

    NASA Astrophysics Data System (ADS)

    Dammak, Salma; Palma, David; Mattonen, Sarah; Senan, Suresh; Ward, Aaron D.

    2018-02-01

    Stereotactic ablative radiotherapy (SABR) is the standard treatment recommendation for Stage I non-small cell lung cancer (NSCLC) patients who are inoperable or who refuse surgery. This option is well tolerated by even unfit patients and has a low recurrence risk post-treatment. However, SABR induces changes in the lung parenchyma that can appear similar to those of recurrence, and the difference between the two at an early follow-up time point is not easily distinguishable for an expert physician. We hypothesized that a radiomics signature derived from standard-of-care computed tomography (CT) imaging can detect cancer recurrence within six months of SABR treatment. This study reports on the design phase of our work, with external validation planned in future work. In this study, we performed cross-validation experiments with four feature selection approaches and seven classifiers on an 81-patient data set. We extracted 104 radiomics features from the consolidative and the peri-consolidative regions on the follow-up CT scans. The best results were achieved using the sum of estimated Mahalanobis distances (Maha) for supervised forward feature selection and a trainable automatic radial basis support vector classifier (RBSVC). This system produced an area under the receiver operating characteristic curve (AUC) of 0.84, an error rate of 16.4%, a false negative rate of 12.7%, and a false positive rate of 20.0% for leaveone patient out cross-validation. This suggests that once validated on an external data set, radiomics could reliably detect post-SABR recurrence and form the basis of a tool assisting physicians in making salvage treatment decisions.

  15. Detection of early changes in lung cell cytology by flow-systems analysis techniques

    SciT

    Steinkamp, J.A.; Hansen, K.M.; Wilson, J.S.

    1976-12-01

    This report summarizes results of continuing experiments to develop cytological and biochemical indicators for estimating damage to respiratory cells in test animals exposed by inhalation to toxic agents associated with nonnuclear energy production, the specific goal being the application of advanced multiparameter flow-systems technologies to the detection of early atypical cellular changes in lung epithelium. Normal Syrian hamster lung cell samples composed of macrophages, leukocytes, ciliated columnar cells, and epithelial cells were stained with fluorescent dyes specific for different biochemical parameters and were analyzed in liquid suspension as they flowed through a chamber intersecting a laser beam of exciting light.more » Multiple sensors measured the total or two-color fluorescence and light scatter on a cell-by-cell basis. Cellular parameters proportional to optical measurements (i.e., cell size, DNA content, total protein, nonspecific esterase activity, nuclear and cytoplasmic diameters) were displayed as frequency distribution histograms. Lung cell samples were also separated according to various cytological parameters and identified microscopically. The basic operating features of the methodology are discussed briefly, along with specific examples of preliminary results illustrating the initial characterization of exfoliated pulmonary cells from normal hamsters. As the flow technology is adapted further to the analysis of respiratory cells, measurements of changes in physical and biochemical properties as a function of exposure to toxic agents will be performed.« less

  16. Factors influencing performance of internet-based biosurveillance systems used in epidemic intelligence for early detection of infectious diseases outbreaks.

    PubMed

    Barboza, Philippe; Vaillant, Laetitia; Le Strat, Yann; Hartley, David M; Nelson, Noele P; Mawudeku, Abla; Madoff, Lawrence C; Linge, Jens P; Collier, Nigel; Brownstein, John S; Astagneau, Pascal

    2014-01-01

    Internet-based biosurveillance systems have been developed to detect health threats using information available on the Internet, but system performance has not been assessed relative to end-user needs and perspectives. Infectious disease events from the French Institute for Public Health Surveillance (InVS) weekly international epidemiological bulletin published in 2010 were used to construct the gold-standard official dataset. Data from six biosurveillance systems were used to detect raw signals (infectious disease events from informal Internet sources): Argus, BioCaster, GPHIN, HealthMap, MedISys and ProMED-mail. Crude detection rates (C-DR), crude sensitivity rates (C-Se) and intrinsic sensitivity rates (I-Se) were calculated from multivariable regressions to evaluate the systems' performance (events detected compared to the gold-standard) 472 raw signals (Internet disease reports) related to the 86 events included in the gold-standard data set were retrieved from the six systems. 84 events were detected before their publication in the gold-standard. The type of sources utilised by the systems varied significantly (p<0001). I-Se varied significantly from 43% to 71% (p=0001) whereas other indicators were similar (C-DR: p=020; C-Se, p=013). I-Se was significantly associated with individual systems, types of system, languages, regions of occurrence, and types of infectious disease. Conversely, no statistical difference of C-DR was observed after adjustment for other variables. Although differences could result from a biosurveillance system's conceptual design, findings suggest that the combined expertise amongst systems enhances early detection performance for detection of infectious diseases. While all systems showed similar early detection performance, systems including human moderation were found to have a 53% higher I-Se (p=00001) after adjustment for other variables. Overall, the use of moderation, sources, languages, regions of occurrence, and types of cases

  17. A prototype sensor system for the early detection of microbially linked spoilage in stored wheat grain

    NASA Astrophysics Data System (ADS)

    de Lacy Costello, B. P. J.; Ewen, R. J.; Gunson, H.; Ratcliffe, N. M.; Sivanand, P. S.; Spencer-Phillips, P. T. N.

    2003-04-01

    Sensors based on composites of metal oxides were fabricated and tested extensively under high-humidity and high-flow conditions with exposure to vapours reported to increase in the headspace of wheat grain (Triticum aestivum cv Hereward) colonized by fungi. The sensors that exhibited high sensitivity to target vapours combined with high stability were selected for inclusion into a four-sensor array prototype system. A sampling protocol aligned to parallel gas chromatography-mass spectrometry and human olfactory assessment studies was established for use with the sensor system. The sensor system was utilized to assess irradiated wheat samples that had been conditioned to 25% moisture content and inoculated with pathogens known to cause spoilage of grain in storage. These included the fungi Penicillium aurantiogriseum, Penicillium vulpinum, Penicillium verrucosum, Fusarium culmorum, Aspergillus niger, and Aspergillus flavus and the actinomycete, Streptomyces griseus. The sensor system successfully tracked the progress of the infections from a very early stage and the results were compared with human olfactory assessment panels run concurrently. A series of dilution studies were undertaken using previously infected grain mixed with sound grain, to improve the sensitivity and maximize the differentiation of the sensor system. An optimum set of conditions including incubation temperature, incubation time, sampling time, and flow rate were ascertained utilizing this method. The sensor system differentiated samples of sound grain from samples of sound grain with 1% (w/w) fungus infected grain added. Following laboratory trials, the prototype sensor system was evaluated in a commercial wheat grain intake facility. Thresholds calculated from laboratory tests were used to differentiate between sound and infected samples (classified by intake laboratory technicians) collected routinely from trucks delivering grain for use in food manufacture. All samples identified as having

  18. Early Warning/Track-and-Trigger Systems to Detect Deterioration and Improve Outcomes in Hospitalized Patients.

    PubMed

    Shiloh, Ariel L; Lominadze, George; Gong, Michelle N; Savel, Richard H

    2016-02-01

    As a global effort toward improving patient safety, a specific area of focus has been the early recognition and rapid intervention in deteriorating ward patients. This focus on "failure to rescue" has led to the construction of early warning/track-and-trigger systems. In this review article, we present a description of the data behind the creation and implementation of such systems, including multiple algorithms and strategies for deployment. Additionally, the strengths and weaknesses of the various systems and their evaluation in the literature are emphasized. Despite the limitations of the current literature, the potential benefit of these early warning/track-and-trigger systems to improve patient outcomes remains significant. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. A multi-wavelength (u.v. to visible) laser system for early detection of oral cancer

    NASA Astrophysics Data System (ADS)

    Najda, S. P.; Perlin, P.; Leszczyński, M.; Slight, T. J.; Meredith, W.; Schemmann, M.; Moseley, H.; Woods, J. A.; Valentine, R.; Kalra, S.; Mossey, P.; Theaker, E.; Macluskey, M.; Mimnagh, G.; Mimnagh, W.

    2015-03-01

    A multi-wavelength (360nm - 440nm), real-time Photonic Cancer Detector (PCD) optical system based on GaN semiconductor laser technology is outlined. A proof of concept using blue laser technology for early detection of cancer has already been tested and proven for esophageal cancer. This concept is expanded to consider a wider range of wavelengths and the PCD will initially be used for early diagnosis of oral cancers. The PCD creates an image of the oral cavity (broad field white light detection) and maps within the oral cavity any suspicious lesions with high sensitivity using a narrow field tunable detector.

  20. Fluorescence Sensors for Early Detection of Nitrification in Drinking Water Distribution Systems – Interference Corrections (Abstract)

    EPA Science Inventory

    Nitrification event detection in chloraminated drinking water distribution systems (DWDSs) remains an ongoing challenge for many drinking water utilities, including Dallas Water Utilities (DWU) and the City of Houston (CoH). Each year, these utilities experience nitrification eve...

  1. Fluorescence Sensors for Early Detection of Nitrification in Drinking Water Distribution Systems – Interference Corrections (Poster)

    EPA Science Inventory

    Nitrification event detection in chloraminated drinking water distribution systems (DWDSs) remains an ongoing challenge for many drinking water utilities, including Dallas Water Utilities (DWU) and the City of Houston (CoH). Each year, these utilities experience nitrification eve...

  2. Metabolic system alterations in pancreatic cancer patient serum: potential for early detection

    PubMed Central

    2013-01-01

    Background The prognosis of pancreatic cancer (PC) is one of the poorest among all cancers, due largely to the lack of methods for screening and early detection. New biomarkers for identifying high-risk or early-stage subjects could significantly impact PC mortality. The goal of this study was to find metabolic biomarkers associated with PC by using a comprehensive metabolomics technology to compare serum profiles of PC patients to healthy control subjects. Methods A non-targeted metabolomics approach based on high-resolution, flow-injection Fourier transform ion cyclotron resonance mass spectrometry (FI-FTICR-MS) was used to generate comprehensive metabolomic profiles containing 2478 accurate mass measurements from the serum of Japanese PC patients (n=40) and disease-free subjects (n=50). Targeted flow-injection tandem mass spectrometry (FI-MS/MS) assays for specific metabolic systems were developed and used to validate the FI-FTICR-MS results. A FI-MS/MS assay for the most discriminating metabolite discovered by FI-FTICR-MS (PC-594) was further validated in two USA Caucasian populations; one comprised 14 PCs, six intraductal papillary mucinous neoplasims (IPMN) and 40 controls, and a second comprised 1000 reference subjects aged 30 to 80, which was used to create a distribution of PC-594 levels among the general population. Results FI-FTICR-MS metabolomic analysis showed significant reductions in the serum levels of metabolites belonging to five systems in PC patients compared to controls (all p<0.000025). The metabolic systems included 36-carbon ultra long-chain fatty acids, multiple choline-related systems including phosphatidylcholines, lysophosphatidylcholines and sphingomyelins, as well as vinyl ether-containing plasmalogen ethanolamines. ROC-AUCs based on FI-MS/MS of selected markers from each system ranged between 0.93 ±0.03 and 0.97 ±0.02. No significant correlations between any of the systems and disease-stage, gender, or treatment were observed

  3. Earth Observations for Early Detection of Agricultural Drought: Contributions of the Famine Early Warning Systems Network (FEWS NET)

    NASA Astrophysics Data System (ADS)

    Budde, M. E.; Funk, C.; Husak, G. J.; Peterson, P.; Rowland, J.; Senay, G. B.; Verdin, J. P.

    2016-12-01

    The U.S. Geological Survey (USGS) has a long history of supporting the use of Earth observation data for food security monitoring through its role as an implementing partner of the Famine Early Warning Systems Network (FEWS NET) program. The use of remote sensing and crop modeling to address food security threats in the form of drought, floods, pests, and changing climatic regimes has been a core activity in monitoring FEWS NET countries. In recent years, it has become a requirement that FEWS NET apply monitoring and modeling frameworks at global scales to assess emerging crises in regions that FEWS NET does not traditionally monitor. USGS FEWS NET, in collaboration with the University of California, Santa Barbara, has developed a number of new global applications of satellite observations, derived products, and efficient tools for visualization and analyses to address these requirements. (1) A 35-year quasi-global (+/- 50 degrees latitude) time series of gridded rainfall estimates, the Climate Hazards Infrared Precipitation with Stations (CHIRPS) dataset, based on infrared satellite imagery and station observations. Data are available as 5-day (pentadal) accumulations at 0.05 degree spatial resolution. (2) Global actual evapotranspiration data based on application of the Simplified Surface Energy Balance (SSEB) model using 10-day MODIS Land Surface Temperature composites at 1-km resolution. (3) Production of global expedited MODIS (eMODIS) 10-day NDVI composites updated every 5 days. (4) Development of an updated Early Warning eXplorer (EWX) tool for data visualization, analysis, and sharing. (5) Creation of stand-alone tools for enhancement of gridded rainfall data and trend analyses. (6) Establishment of an agro-climatology analysis tool and knowledge base for more than 90 countries of interest to FEWS NET. In addition to these new products and tools, FEWS NET has partnered with the GEOGLAM community to develop a Crop Monitor for Early Warning (CM4EW) which

  4. Factors Influencing Performance of Internet-Based Biosurveillance Systems Used in Epidemic Intelligence for Early Detection of Infectious Diseases Outbreaks

    PubMed Central

    Barboza, Philippe; Vaillant, Laetitia; Le Strat, Yann; Hartley, David M.; Nelson, Noele P.; Mawudeku, Abla; Madoff, Lawrence C.; Linge, Jens P.; Collier, Nigel; Brownstein, John S.; Astagneau, Pascal

    2014-01-01

    Background Internet-based biosurveillance systems have been developed to detect health threats using information available on the Internet, but system performance has not been assessed relative to end-user needs and perspectives. Method and Findings Infectious disease events from the French Institute for Public Health Surveillance (InVS) weekly international epidemiological bulletin published in 2010 were used to construct the gold-standard official dataset. Data from six biosurveillance systems were used to detect raw signals (infectious disease events from informal Internet sources): Argus, BioCaster, GPHIN, HealthMap, MedISys and ProMED-mail. Crude detection rates (C-DR), crude sensitivity rates (C-Se) and intrinsic sensitivity rates (I-Se) were calculated from multivariable regressions to evaluate the systems’ performance (events detected compared to the gold-standard) 472 raw signals (Internet disease reports) related to the 86 events included in the gold-standard data set were retrieved from the six systems. 84 events were detected before their publication in the gold-standard. The type of sources utilised by the systems varied significantly (p<0001). I-Se varied significantly from 43% to 71% (p = 0001) whereas other indicators were similar (C-DR: p = 020; C-Se, p = 013). I-Se was significantly associated with individual systems, types of system, languages, regions of occurrence, and types of infectious disease. Conversely, no statistical difference of C-DR was observed after adjustment for other variables. Conclusion Although differences could result from a biosurveillance system's conceptual design, findings suggest that the combined expertise amongst systems enhances early detection performance for detection of infectious diseases. While all systems showed similar early detection performance, systems including human moderation were found to have a 53% higher I-Se (p = 00001) after adjustment for other variables. Overall, the use of

  5. Development of an e-learning system for teaching endoscopists how to diagnose early gastric cancer: basic principles for improving early detection.

    PubMed

    Yao, Kenshi; Uedo, Noriya; Muto, Manabu; Ishikawa, Hideki

    2017-03-01

    We developed an internet e-learning system in order to improve the ability of endoscopists to diagnose gastric cancer at an early stage. The efficacy of this system at expanding knowledge and providing invaluable experience regarding the endoscopic detection of early gastric cancer was demonstrated through an international multicenter randomized controlled trial. However, the contents of the system have not yet been fully described in the literature. Accordingly, we herein introduce the contents and their principles, which comprise three main subjects: technique, knowledge, and experience. Since all the e-learning contents and principles are based on conventional white-light endoscopy alone, which is commonly available throughout the world, they should provide a good reference point for any endoscopist who wishes to devise learning materials and guidelines for improving their own clinical practice.

  6. Development of a Global Agricultural Hotspot Detection and Early Warning System

    NASA Astrophysics Data System (ADS)

    Lemoine, G.; Rembold, F.; Urbano, F.; Csak, G.

    2015-12-01

    The number of web based platforms for crop monitoring has grown rapidly over the last years and anomaly maps and time profiles of remote sensing derived indicators can be accessed online thanks to a number of web based portals. However, while these systems make available a large amount of crop monitoring data to the agriculture and food security analysts, there is no global platform which provides agricultural production hotspot warning in a highly automatic and timely manner. Therefore a web based system providing timely warning evidence as maps and short narratives is currently under development by the Joint Research Centre. The system (called "HotSpot Detection System of Agriculture Production Anomalies", HSDS) will focus on water limited agricultural systems worldwide. The automatic analysis of relevant meteorological and vegetation indicators at selected administrative units (Gaul 1 level) will trigger warning messages for the areas where anomalous conditions are observed. The level of warning (ranging from "watch" to "alert") will depend on the nature and number of indicators for which an anomaly is detected. Information regarding the extent of the agricultural areas concerned by the anomaly and the progress of the agricultural season will complement the warning label. In addition, we are testing supplementary detailed information from other sources for the areas triggering a warning. These regard the automatic web-based and food security-tailored analysis of media (using the JRC Media Monitor semantic search engine) and the automatic detection of active crop area using Sentinel 1, upcoming Sentinel-2 and Landsat 8 imagery processed in Google Earth Engine. The basic processing will be fully automated and updated every 10 days exploiting low resolution rainfall estimates and satellite vegetation indices. Maps, trend graphs and statistics accompanied by short narratives edited by a team of crop monitoring experts, will be made available on the website on a

  7. GammaScorpion: mobile gamma-ray tomography system for early detection of basal stem rot in oil palm plantations

    NASA Astrophysics Data System (ADS)

    Abdullah, Jaafar; Hassan, Hearie; Shari, Mohamad Rabaie; Mohd, Salzali; Mustapha, Mahadi; Mahmood, Airwan Affendi; Jamaludin, Shahrizan; Ngah, Mohd Rosdi; Hamid, Noor Hisham

    2013-03-01

    Detection of the oil palm stem rot disease Ganoderma is a major issue in estate management and production in Malaysia. Conventional diagnostic techniques are difficult and time consuming when using visual inspection, and destructive and expensive when based on the chemical analysis of root or stem tissue. As an alternative, a transportable gamma-ray computed tomography system for the early detection of basal stem rot (BSR) of oil palms due to Ganoderma was developed locally at the Malaysian Nuclear Agency, Kajang, Malaysia. This system produces high quality tomographic images that clearly differentiate between healthy and Ganoderma infected oil palm stems. It has been successfully tested and used to detect the extent of BSR damage in oil palm plantations in Malaysia without the need to cut down the trees. This method offers promise for in situ inspection of oil palm stem diseases compared to the more conventional methods.

  8. Development of systems for detection, early warning, and control of pipeline leakage in drinking water distribution: a case study.

    PubMed

    Li, Weifeng; Ling, Wencui; Liu, Suoxiang; Zhao, Jing; Liu, Ruiping; Chen, Qiuwen; Qiang, Zhimin; Qu, Jiuhui

    2011-01-01

    Water leakage in drinking water distribution systems is a serious problem for many cities and a huge challenge for water utilities. An integrated system for the detection, early warning, and control of pipeline leakage has been developed and successfully used to manage the pipeline networks in selected areas of Beijing. A method based on the geographic information system has been proposed to quickly and automatically optimize the layout of the instruments which detect leaks. Methods are also proposed to estimate the probability of each pipe segment leaking (on the basis of historic leakage data), and to assist in locating the leakage points (based on leakage signals). The district metering area (DMA) strategy is used. Guidelines and a flowchart for establishing a DMA to manage the large-scale looped networks in Beijing are proposed. These different functions have been implemented into a central software system to simplify the day-to-day use of the system. In 2007 the system detected 102 non-obvious leakages (i.e., 14.2% of the total detected in Beijing) in the selected areas, which was estimated to save a total volume of 2,385,000 m3 of water. These results indicate the feasibility, efficiency and wider applicability of this system.

  9. Detection of rain events in radiological early warning networks with spectro-dosimetric systems

    NASA Astrophysics Data System (ADS)

    Dąbrowski, R.; Dombrowski, H.; Kessler, P.; Röttger, A.; Neumaier, S.

    2017-10-01

    Short-term pronounced increases of the ambient dose equivalent rate, due to rainfall are a well-known phenomenon. Increases in the same order of magnitude or even below may also be caused by a nuclear or radiological event, i.e. by artificial radiation. Hence, it is important to be able to identify natural rain events in dosimetric early warning networks and to distinguish them from radiological events. Novel spectrometric systems based on scintillators may be used to differentiate between the two scenarios, because the measured gamma spectra provide significant nuclide-specific information. This paper describes three simple, automatic methods to check whether an dot H*(10) increase is caused by a rain event or by artificial radiation. These methods were applied to measurements of three spectrometric systems based on CeBr3, LaBr3 and SrI2 scintillation crystals, investigated and tested for their practicability at a free-field reference site of PTB.

  10. Fluorescence Sensors for Early Detection of Nitrification in Drinking Water Distribution Systems - Interference Corrections and Feasibility Assessment

    NASA Astrophysics Data System (ADS)

    Do, T. D.; Pifer, A.; Chowdhury, Z.; Wahman, D.; Zhang, W.; Fairey, J.

    2017-12-01

    Detection of nitrification events in chloraminated drinking water distribution systems remains an ongoing challenge for many drinking water utilities, including Dallas Water Utilities (DWU) and the City of Houston (CoH). Each year, these utilities experience nitrification events that necessitate extensive flushing, resulting in the loss of billions of gallons of finished water. Biological techniques used to quantify the activity of nitrifying bacteria are impractical for real-time monitoring because they require significant laboratory efforts and/or lengthy incubation times. At present, DWU and CoH regularly rely on physicochemical parameters including total chlorine and monochloramine residual, and free ammonia, nitrite, and nitrate as indicators of nitrification, but these metrics lack specificity to nitrifying bacteria. To improve detection of nitrification in chloraminated drinking water distribution systems, we seek to develop a real-time fluorescence-based sensor system to detect the early onset of nitrification events by measuring the fluorescence of soluble microbial products (SMPs) specific to nitrifying bacteria. Preliminary data indicates that fluorescence-based metrics have the sensitivity to detect these SMPs in the early stages of nitrification, but several remaining challenges will be explored in this presentation. We will focus on benchtop and sensor results from ongoing batch and annular reactor experiments designed to (1) identify fluorescence wavelength pairs and data processing techniques suitable for measurement of SMPs from nitrification and (2) assess and correct potential interferences, such as those from monochloramine, pH, iron, nitrite, nitrate and humic substances. This work will serve as the basis for developing fluorescence sensor packages for full-scale testing and validation in the DWU and CoH systems. Findings from this research could be leveraged to identify nitrification events in their early stages, facilitating proactive

  11. From Data to Knowledge — Faster: GOES Early Fire Detection System to Inform Operational Wildfire Response and Management

    NASA Astrophysics Data System (ADS)

    Koltunov, A.; Quayle, B.; Prins, E. M.; Ambrosia, V. G.; Ustin, S.

    2014-12-01

    Fire managers at various levels require near-real-time, low-cost, systematic, and reliable early detection capabilities with minimal latency to effectively respond to wildfire ignitions and minimize the risk of catastrophic development. The GOES satellite images collected for vast territories at high temporal frequencies provide a consistent and reliable source for operational active fire mapping realized by the WF-ABBA algorithm. However, their potential to provide early warning or rapid confirmation of initial fire ignition reports from conventional sources remains underutilized, partly because the operational wildfire detection has been successfully optimized for users and applications for which timeliness of initial detection is a low priority, contrasting to the needs of first responders. We present our progress in developing the GOES Early Fire Detection (GOES-EFD) system, a collaborative effort led by University of California-Davis and USDA Forest Service. The GOES-EFD specifically focuses on first detection timeliness for wildfire incidents. It is automatically trained for a monitored scene and capitalizes on multiyear cross-disciplinary algorithm research. Initial retrospective tests in Western US demonstrate significantly earlier identification detection of new ignitions than existing operational capabilities and a further improvement prospect. The GOES-EFD-β prototype will be initially deployed for the Western US region to process imagery from GOES-NOP and the rapid and 4 times higher spatial resolution imagery from GOES-R — the upcoming next generation of GOES satellites. These and other enhanced capabilities of GOES-R are expected to significantly improve the timeliness of fire ignition information from GOES-EFD.

  12. A pilot study of dentists' assessment of caries detection and staging systems applied to early caries: PEARL Network findings.

    PubMed

    Thompson, Van P; Schenkel, Andrew B; Penugonda, Bapanaiah; Wolff, Mark S; Zeller, Gregory G; Wu, Hongyu; Vena, Don; Grill, Ashley C; Curro, Frederick A

    2016-01-01

    The International Caries Detection and Assessment System (ICDAS II) and the Caries Classification System (CCS) are caries stage description systems proposed for adoption into clinical practice. This pilot study investigated clinicians' training in and use of these systems for detection of early caries and recommendations for individual tooth treatment. Patient participants (N = 8) with a range of noncavitated lesions (CCS ranks 2 and 4 and ICDAS II ranks 2-4) identified by a team of calibrated examiners were recruited from the New York University College of Dentistry clinic. Eighteen dentists-8 from the Practitioners Engaged in Applied Research and Learning (PEARL) Network and 10 recruited from the Academy of General Dentistry-were randomly assigned to 1 of 3 groups: 5 dentists used only visual-tactile (VT) examination, 7 were trained in the ICDAS II, and 6 were trained in the CCS. Lesion stage for each tooth was determined by the ICDAS II and CCS groups, and recommended treatment was decided by all groups. Teeth were assessed both with and without radiographs. Caries was detected in 92.7% (95% CI, 88%-96%) of the teeth by dentists with CCS training, 88.8% (95% CI, 84%-92%) of the teeth by those with ICDAS II training, and 62.3% (95% CI, 55%-69%) of teeth by the VT group. Web-based training was acceptable to all dentists in the CCS group (6 of 6) but fewer of the dentists in the ICDAS II group (5 of 7). The modified CCS translated clinically to more accurate caries detection, particularly compared to detection by untrained dentists (VT group). Moreover, the CCS was more accepted than was the ICDAS II, but dentists in both groups were open to the application of these systems. Agreement on caries staging requires additional training prior to a larger validation study.

  13. Numerical and experimental analysis of high frequency acoustic microscopy and infrared reflectance system for early detection of melanoma

    NASA Astrophysics Data System (ADS)

    Karagiannis, Georgios; Apostolidis, Georgios; Georgoulias, Panagiotis

    2016-03-01

    Melanoma is a very malicious type of cancer as it metastasizes early and hence its late diagnosis leads to death. Consequently, early diagnosis of melanoma and its removal is considered the most effective way of treatment. We present a design of a high frequency acoustic microscopy and infrared reflectance system for the early detection of melanoma. Specifically, the identification of morphological changes related to carcinogenesis is required. In this work, we simulate of the propagation of the ultrasonic waves of the order of 100 MHz as well as of electromagnetic waves of the order of 100 THz in melanoma structures targeting to the estimation and optimization of the basic characteristics of the systems. The simulation results of the acoustic microscopy subsystem aim to provide information such as the geometry of the transducer, the center frequency of operation, the focal length where the power transmittance is optimum and the spot size in focal length. As far as the infrared is concerned the optimal frequency range and the spot illumination size of the external probe is provided. This information is next used to assemble a properly designed system which is applied to melanoma phantoms as well as real skin lesions. Finally, the measurement data are visualized to reveal the information of the experimented structures, proving noteworthy accuracy.

  14. Consumer participation in early detection of the deteriorating patient and call activation to rapid response systems: a literature review.

    PubMed

    Vorwerk, Jane; King, Lindy

    2016-01-01

    This review investigated the impact of consumer participation in recognition of patient deterioration and response through call activation in rapid response systems. Nurses and doctors have taken the main role in recognition and response to patient deterioration through hospital rapid response systems. Yet patients and visitors (consumers) have appeared well placed to notice early signs of deterioration. In response, many hospitals have sought to partner health professionals with consumers in detection and response to early deterioration. However, to date, there have been no published research-based reviews to establish the impact of introducing consumer involvement into rapid response systems. A critical research-based review was undertaken. A comprehensive search of databases from 2006-2014 identified 11 studies. Critical appraisal of these studies was undertaken and thematic analysis of the findings revealed four major themes. Following implementation of the consumer activation programmes, the number of calls made by the consumers following detection of deterioration increased. Interestingly, the number of staff calls also increased. Importantly, mortality numbers were found to decrease in one major study following the introduction of consumer call activation. Consumer and staff knowledge and satisfaction with the new programmes indicated mixed results. Initial concerns of the staff over consumer involvement overwhelming the rapid response systems did not eventuate. Evaluation of successful consumer-activated programmes indicated the importance of: effective staff education and training; ongoing consumer education by nurses and clear educational materials. Findings indicated positive patient outcomes following introduction of consumer call activation programmes within rapid response systems. Effective consumer programmes included information that was readily accessible, easy-to-understand and available in a range of multimedia materials accompanied by the

  15. The Effect Of Pixel Size On The Detection Rate Of Early Pulmonary Sarcoidosis In Digital Chest Radiographic Systems

    NASA Astrophysics Data System (ADS)

    MacMahon, Heber; Vyborny, Carl; Powell, Gregory; Doi, Kunio; Metz, Charles E.

    1984-08-01

    In digital radiography the pixel size used determines the potential spatial resolution of the system. The need for spatial resolution varies depending on the subject matter imaged. In many areas, including the chest, the minimum spatial resolution requirements have not been determined. Sarcoidosis is a disease which frequently causes subtle interstitial infiltrates in the lungs. As the initial step in an investigation designed to determine the minimum pixel size required in digital chest radiographic systems, we have studied 1 mm pixel digitized images on patients with early pulmonary sarcoidosis. The results of this preliminary study suggest that neither mild interstitial pulmonary infiltrates nor other abnormalities such as pneumothoraces may be detected reliably with 1 mm pixel digital images.

  16. Development of a Computer-aided Diagnosis System for Early Detection of Masses Using Retrospectively Detected Cancers on Prior Mammograms

    DTIC Science & Technology

    2009-06-01

    131 cases with 131 biopsy proven masses, of which 27 were malignant and 104 benign. The true locations of the masses were identified by an experi- enced ...two acquisitions would cause differ- ences in the subtlety of the masses on the FFDMs and SFMs. However, assuming that the differences are ran- dom... Lado , M. Souto, and J. J. Vidal, “Computer-aided diagnosis: Automatic detection of malignant masses in digitized mammograms,” Med. Phys. 25, 957–964

  17. Development of a Computer-Aided Diagnosis System for Early Detection of Masses Using Retrospectively Detected Cancers on Prior Mammograms

    DTIC Science & Technology

    2006-06-01

    Hadjiiski, and N. Petrick, "Computerized nipple identification for multiple image analysis in computer-aided diagnosis," Medical Physics 31, 2871...candidates, 3 identification of suspicious objects, 4 feature extraction and analysis, and 5 FP reduc- tion by classification of normal tissue...detection of microcalcifi- cations on digitized mammograms.41 An illustration of a La- placian decomposition tree is shown on the left-hand side of Fig. 4

  18. Computer-aided detection systems to improve lung cancer early diagnosis: state-of-the-art and challenges

    NASA Astrophysics Data System (ADS)

    Traverso, A.; Lopez Torres, E.; Fantacci, M. E.; Cerello, P.

    2017-05-01

    Lung cancer is one of the most lethal types of cancer, because its early diagnosis is not good enough. In fact, the detection of pulmonary nodule, potential lung cancers, in Computed Tomography scans is a very challenging and time-consuming task for radiologists. To support radiologists, researchers have developed Computer-Aided Diagnosis (CAD) systems for the automated detection of pulmonary nodules in chest Computed Tomography scans. Despite the high level of technological developments and the proved benefits on the overall detection performance, the usage of Computer-Aided Diagnosis in clinical practice is far from being a common procedure. In this paper we investigate the causes underlying this discrepancy and present a solution to tackle it: the M5L WEB- and Cloud-based on-demand Computer-Aided Diagnosis. In addition, we prove how the combination of traditional imaging processing techniques with state-of-art advanced classification algorithms allows to build a system whose performance could be much larger than any Computer-Aided Diagnosis developed so far. This outcome opens the possibility to use the CAD as clinical decision support for radiologists.

  19. First open field measurements with a portable CO2 lidar/dial system for early forest fires detection

    NASA Astrophysics Data System (ADS)

    Gaudio, Pasquale; Gelfusa, Michela; Lupelli, Ivan; Malizia, Andrea; Moretti, Alessandro; Richetta, Maria; Serafini, Camilla; Bellecci, Carlo

    2011-11-01

    Lidar and dial are well established methods to explore the atmosphere. Different groups have already shown experimentally the possibility to measure the density variation of aerosol and particulate in the atmosphere due to plumes emitted in forest fires with this kind of systems. The aim of the present work is to demonstrate the capabilities of our mobile Lidar system, based on a CO2 laser, to detect forest fires and minimizing false alarms. For this purpose, our system can be operated in both lidar and dial configurations in sequence. The first Lidar measurement is performed to evaluate the variation of the local density into the atmosphere, using a nonabsorption water wavelength 10R18 (10.571 μm). If the returned signal reports a backscattering peak, the presence of a fire is probable. To confirm this hypothesis, a second dial measurement is carried out to reveal a second component emitted during the combustion process. The chosen second component is water vapour, which is, as it is well-known, largely produced during the first combustion stage. Measuring the water concentration peak after the detection of the aerosol density increment (referred to the standard mean atmospheric value) represents a good method to reduce false alarms with a dial system. In order to test this methodology, a first set of measurements has been performed in a field near the Engineering Faculty of the University of Rome "Tor Vergata". A quite small controlled-fire has been lighted into a box at a distance of about one kilometre from the system. The data acquired at the two wavelengths (10R18 and 10R20) have been averaged on 100 elastic backscattered Lidar signals. The first results confirm the effectiveness of the measurement strategy for reducing the number of false alarm preserving the early detection.

  20. Improving trapping systems for early detection and eradication of fruit flies (Diptera: Tephritidae) in California

    Solid Mallet TMR (trimedlure [TML], methyl eugenol [ME], raspberry ketone [RK]) wafers and Mallet CMR (ceralure, ME, RK, benzyl acetate) wafers impregnated with DDVP insecticide were evaluated in traps as potential detection and male annihilation devices. Comparisons were made with 1) liquid lure an...

  1. Managing for resilience: early detection of regime shifts in complex systems

    EPA Science Inventory

    The goal of sustainability is to maintain a condition or regime of the Earth, which supports human existence from generation to generation. Hence, the ability to detect, characterize, and manage regime shifts, particularly catastrophic ones, is critical to maintaining human sust...

  2. Early detection of foot-and-mouth disease virus from infected cattle using a dry filter air sampling system

    Foot-and-mouth disease (FMD) is a highly contagious livestock disease of high economic impact. Early detection of FMD virus (FMDV) is fundamental for rapid outbreak control. Air sampling collection has been demonstrated as a useful technique for detection of FMDV RNA in infected animals, related to ...

  3. Detection of early changes in lung cell cytology by flow-systems analysis techniques, July 1--December 31, 1975

    SciT

    Steinkamp, J.A.; Ingram, M.; Hansen, K.M.

    1976-03-01

    This report summarizes results of preliminary experiments to demonstrate the feasibility of using automated flow-systems analysis in detecting early changes of respiratory epithelium exposed to physical and chemical agents associated with the by-products of nonnuclear energy production. The Syrian hamster was selected as the experimental test animal to begin investigation of the effects of toxic agents to cells of the respiratory tract. Since initiation of the program approximately six months ago, the goals have been acquisition of adequate numbers of exfoliated cells from the lung; adaptation of cytological techniques developed on human exfoliated gynecological samples to hamster lung epithelium formore » obtaining single-cell suspensions; utilization of existing cell staining methods to measure DNA content in lung cells; and analysis of DNA content and cell size. As the flow-system cell analysis technology is adapted to the measurement of exfoliated lung cells, rapid and quantitative determination of early changes in the physical and biochemical cellular properties will be attempted as a function of exposure to the toxic agents. (auth)« less

  4. Development of an Early Warning Fire Detection System using Correlation Spectroscopy

    NASA Technical Reports Server (NTRS)

    Goswami, K.; Voevodkin, G.; Rubstov, V.; Lieberman, R.; Piltch, N.

    2001-01-01

    Combustion byproducts are numerous. A few examples of the gaseous byproducts include carbon dioxide, carbon monoxide, hydrogen chloride, hydrogen cyanide and ammonia. For detecting these chemical species, classic absorption spectroscopy has been used for many decades, but the sensitivity of steady-state methods is often unsuitable for the detection of trace compounds at the low levels (parts per million to parts per billion) appropriate for scientific purposes. This is particularly so for monitoring equipment, which must be compact and cost-effective, and which is often subjected to shock, vibration, and other environmental effects that can severely degrade the performance of high-sensitivity spectrometers in an aircraft. Steady-state techniques also suffer from a lack of specificity; the deconvolution of the spectra of complex mixtures is a laborious and error prone process. These problems are exacerbated in remote fiber-optic monitoring where, for practical reasons, the fundamental absorbance region of the spectrum (often between 3 and 8 microns) is inaccessible, and the low-strength, closely spaced, near-infrared overtone absorbance bands must be used. We circumvented these challenges by employing correlation spectroscopy, a variation of modulation spectroscopy.

  5. Early Detection of Regime Shifts in Complex Systems from Fisher Information

    EPA Science Inventory

    The central goal of sustainability is the maintenance of environmental conditions, which are favorable to human existence. A critically important element then is the resilience of the dynamic regime that one wishes to sustain. Resilient systems are able to withstand perturbations...

  6. Early Detection and Prevention of Mental Health Problems: Developmental Epidemiology and Systems of Support.

    PubMed

    Costello, E Jane

    2016-01-01

    This article reviews the role of developmental epidemiology in the prevention of child and adolescent mental disorders and the implications for systems of support. The article distinguishes between universal or primary prevention, which operates at the level of the whole community to limit risk exposure before the onset of symptoms, and secondary or targeted prevention, which operates by identifying those at high risk of developing a disorder. It discusses different aspects of time as it relates to risk for onset of disease, such as age at first exposure, duration of exposure, age at onset of first symptoms, and time until treatment. The study compares universal and targeted prevention, describing the systems needed to support each, and their unintended consequences.

  7. Gene Expression Profiling of Peripheral Blood From Kidney Transplant Recipients for the Early Detection of Digestive System Cancer.

    PubMed

    Kusaka, M; Okamoto, M; Takenaka, M; Sasaki, H; Fukami, N; Kataoka, K; Ito, T; Kenmochi, T; Hoshinaga, K; Shiroki, R

    2017-06-01

    Kidney transplant recipients are at increased risk of developing cancer in comparison with the general population. To effectively manage post-transplantation malignancies, it is essential to proactively monitor patients. A long-term intensive screening program was associated with a reduced incidence of cancer after transplantation. This study evaluated the usefulness of the gene expression profiling of peripheral blood samples obtained from kidney transplant patients and adopted a screening test for detecting cancer of the digestive system (gastric, colon, pancreas, and biliary tract). Nineteen patients were included in this study and a total of 53 gene expression screening tests were performed. The gene expression profiles of blood-delivered total RNA and whole genome human gene expression profiles were obtained. We investigated the expression levels of 2665 genes associated with digestive cancers and counted the number of genes in which expression was altered. A hierarchical clustering analysis was also performed. The final prediction of the cancer possibility was determined according to an algorithm. The number of genes in which expression was altered was significantly increased in the kidney transplant recipients in comparison with the general population (1091 ± 63 vs 823 ± 94; P = .0024). The number of genes with altered expression decreased after the induction of mechanistic target of rapamycin (mTOR) inhibitor (1484 ± 227 vs 883 ± 154; P = .0439). No cases of possible digestive cancer were detected in this study period. The gene expression profiling of peripheral blood samples may be a useful and noninvasive diagnostic tool that allows for the early detection of cancer of the digestive system. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Evaluating Fluorscence-Based Metrics for Early Detection of ...

    EPA Pesticide Factsheets

    Summary: This paper discusses the results of an ongoing Water Research Foundation project on developing a fluorescence sensor system for early detection of distribution system nitrification Summary: This paper discusses the results of an ongoing Water Research Foundation project on developing a fluorescence sensor system for early detection of distribution system nitrification

  9. Early Detection of Child Abuse

    PubMed Central

    Shearman, J.K.

    1987-01-01

    Child abuse, neglect and deprivation are more common than was previously thought. Family physicians are in a unique position to help abusers and abused because of their knowledge of patients from the cradle to the grave. They should use this knowledge to observe clues about parenting potential and should make a thorough family history a routine part of history taking in potential parents. They should also observe patients carefully during pregnancy and early childhood to detect parenting problems and to try to prevent all types of abuse, physical, mental and sexual. PMID:21267341

  10. [Autism, neurodevelopment and early detection].

    PubMed

    Martos-Pérez, J

    2006-02-13

    Autistic disorder is briefly explained and defined in the light of recent research. From the perspective offered by ontogenesis and the acquisitions that take place during normal development, we present an updated vision of the genesis of autistic disorder and also review the most significant data provided by the different studies that have been conducted on the subject. Detection of the disorder is clearly a difficult task before the age of one year and, in any case, the earliest symptoms are clearly linked to the social and communicative interaction that characteristically takes place at the end of the infant's first year of life. Early detection of the disorder is made possible precisely because of alterations in social and communicative development and, in general, the appearance of psychological functions that play a significant role in the process of humanisation. The article concludes by pointing out the need for further studies that focus on the possible alteration of earlier socio-emotional and affective manifestations.

  11. Proposal of a framework for evaluating military surveillance systems for early detection of outbreaks on duty areas

    PubMed Central

    Meynard, Jean-Baptiste; Chaudet, Herve; Green, Andrew D; Jefferson, Henry L; Texier, Gaetan; Webber, Daniel; Dupuy, Bruce; Boutin, Jean-Paul

    2008-01-01

    Background In recent years a wide variety of epidemiological surveillance systems have been developed to provide early identification of outbreaks of infectious disease. Each system has had its own strengths and weaknesses. In 2002 a Working Group of the Centers for Disease Control and Prevention (CDC) produced a framework for evaluation, which proved suitable for many public health surveillance systems. However this did not easily adapt to the military setting, where by necessity a variety of different parameters are assessed, different constraints placed on the systems, and different objectives required. This paper describes a proposed framework for evaluation of military syndromic surveillance systems designed to detect outbreaks of disease on operational deployments. Methods The new framework described in this paper was developed from the cumulative experience of British and French military syndromic surveillance systems. The methods included a general assessment framework (CDC), followed by more specific methods of conducting evaluation. These included Knowledge/Attitude/Practice surveys (KAP surveys), technical audits, ergonomic studies, simulations and multi-national exercises. A variety of military constraints required integration into the evaluation. Examples of these include the variability of geographical conditions in the field, deployment to areas without prior knowledge of naturally-occurring disease patterns, the differences in field sanitation between locations and over the length of deployment, the mobility of military forces, turnover of personnel, continuity of surveillance across different locations, integration with surveillance systems from other nations working alongside each other, compatibility with non-medical information systems, and security. Results A framework for evaluation has been developed that can be used for military surveillance systems in a staged manner consisting of initial, intermediate and final evaluations. For each stage

  12. Effectiveness of physical exam signs for early detection of critical illness in pediatric systemic inflammatory response syndrome.

    PubMed

    Scott, Halden F; Donoghue, Aaron J; Gaieski, David F; Marchese, Ronald F; Mistry, Rakesh D

    2014-11-19

    Early detection of compensated pediatric septic shock requires diagnostic tests that are sensitive and specific. Four physical exam signs are recommended for detecting pediatric septic shock prior to hypotension (cold extremities, mental status, capillary refill, peripheral pulse quality); this study tested their ability to detect patients who develop organ dysfunction among a cohort of undifferentiated pediatric systemic inflammatory response syndrome patients. A prospective cohort of 239 pediatric emergency department patients <19 years with fever and tachycardia and undergoing phlebotomy were enrolled. Physicians recorded initial physical exams on a standardized form. Abstraction of the medical record determined outcomes including organ dysfunction, intensive care unit stay, serious bacterial infection, and therapies. Organ dysfunction occurred in 13/239 (5.4%) patients. Presence of at least one sign was significantly associated with organ dysfunction (Relative Risk: 2.71, 95% CI: 1.05-6.99), and presence of at least two signs had a Relative Risk = 4.98 (95% CI: 1.82-13.58). The sensitivity of exam findings ranged from 8-54%, specificity from 84-98%. Signs were associated with increased risk of intensive care and fluid bolus, but not with serious bacterial infection, intravenous antibiotics or admission. Altered mental status and peripheral pulse quality were significantly associated with organ dysfunction, while abnormal capillary refill time and presence of cold, mottled extremities were not. Certain recommended physical exam signs were associated with increased risk of organ dysfunction, a rare outcome in this undifferentiated pediatric population with fever and tachycardia. Sensitivity was low, while specificity was high. Additional research into optimally sensitive and specific diagnostic strategies is needed.

  13. Early detection of pancreatic cancer

    PubMed Central

    Ahuja, Nita

    2015-01-01

    Pancreatic adenocarcinoma is a low-incident but highly mortal disease. It accounts for only 3% of estimated new cancer cases each year but is currently the fourth common cause of cancer mortality. By 2030, it is expected to be the 2nd leading cause of cancer death. There is a clear need to diagnose and classify pancreatic cancer at earlier stages in order to give patients the best chance at a definitive cure through surgery. Three precursor lesions that distinctly lead to pancreatic adenocarcinoma have been identified, and we have increasing understanding the non-genetic and genetic risk factors for the disease. With increased understanding about the risk factors, the familial patters, and associated accumulation of genetic mutations involved in pancreatic cancer, we know that there are mutations that occur early in the development of pancreatic cancer and that improved genetic risk-based strategies in screening for pancreatic cancer may be possible and successful at saving or prolonging lives. The remaining challenge is that current standards for diagnosing pancreatic cancer remain too invasive and too costly for widespread screening for pancreatic cancer. Furthermore, the promises of noninvasive methods of detection such as blood, saliva, and stool remain underdeveloped or lack robust testing. However, significant progress has been made, and we are drawing closer to a strategy for the screening and early detection of pancreatic cancer. PMID:26361402

  14. Early Detection of Diabetic Retinopathy.

    PubMed

    Safi, Hamid; Safi, Sare; Hafezi-Moghadam, Ali; Ahmadieh, Hamid

    2018-04-18

    Diabetic retinopathy (DR) is a primary cause of visual impairment worldwide. Diabetes mellitus may be associated with ophthalmoscopically nonvisible neurovascular damage that progresses before the first clinical signs of DR appear. Reduction of the inner neuroretinal layer thickness on macular optical coherence tomography (OCT), reduced contrast sensitivity primarily at low spatial frequencies, abnormal results in color vision and microperimetry tests, and a prolonged implicit time recorded by multifocal electroretinography have been proposed for detection of early functional and nonvisible structural neuroretinal changes. Vascular abnormalities such as changes in the retinal vessels caliber, architectural indices, and blood flow have been investigated to evaluate the early stages of DR. The results of OCT angiography, retinal vessel oxygen saturation patterns, and elevated levels of circulating blood markers and cytokines have been suggested as early signs of DR. Light-based molecular imaging in rodents has been developed to demonstrate changes in protein expressions in the retinal microvessels as diagnostic biomarkers. Future clinical studies will examine the safety and efficacy of this approach in humans. We summarize all studies related to subclinical DR biomarkers. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Early detection and response for measles and rubella cases through the (Nursery) School Absenteeism Surveillance System in Ibaraki Prefecture.

    PubMed

    Watanabe, Miki; Kurita, Junko; Takagi, Takeshi; Nagata, Noriko; Nagasu, Natsuki; Sugawara, Tamie; Ohkusa, Yasushi

    2016-01-01

    Objectives In Ibaraki Prefecture, all (nursery) schools have joined the (Nursery) School Absenteeism Surveillance System (hereafter denoted as (N)SASSy), which is operated by the Japan School Health Association to monitor the prevalence of infectious diseases, the early detection and response for outbreaks, and prevention of large outbreaks. Prefectural government officers also utilize it as a control measure for infectious diseases. In particular, when cases of measles or rubella are registered, (N)SASSy sends e-mails automatically to prefectural government officers to activate control measures. This paper summarizes administrative responses by prefectural government officers for measles or rubella cases using (N)SASSy and discusses the future challenges.Methods We summarized registration, detection, and first response data for measles or rubella cases in (N)SASSy and compared the number of detected and reported cases enforced by the Infectious Diseases Control Law from January 1, 2013 to December 31, 2014.Results The public health center questioned hospitals/clinics and (nursery) schools about all registered measles or rubella cases in (N)SASSy on the same day to check the entered information. In the past 2 years, there were 5 measles and 56 rubella cases in 2013 and 1 measles and 19 rubella cases in 2014 registered with (N)SASSy. All cases were checked and investigated by the public health center. Of all cases detected by (N)SASSy, 7 rubella cases in 2013 and 1 rubella case in 2014 were reported based on the law. No measles cases were reported in the 2 years. The results of investigations and laboratory tests were given as feedback to the (nursery) schools. If the case did not case definition determined by the law, we changed the status in (N)SASSy to suspected or discarded cases.Conclusion Since (N)SASSy assists prefectural government officers with earlier detection of and response for infectious diseases, it definitely contributes to infection control

  16. Early detection and rapid response

    Westbrooks, Randy G.; Eplee, Robert E.; Simberloff, Daniel; Rejmánek, Marcel

    2011-01-01

    Prevention is the first line of defense against introduced invasive species - it is always preferable to prevent the introduction of new invaders into a region or country. However, it is not always possible to detect all alien hitchhikers imported in cargo, or to predict with any degree of certainty which introduced species will become invasive over time. Fortunately, the majority of introduced plants and animals don't become invasive. But, according to scientists at Cornell University, costs and losses due to species that do become invasive are now estimated to be over $137 billion/year in the United States. Early detection and rapid response (EDRR) is the second line of defense against introduced invasive species - EDRR is the preferred management strategy for preventing the establishment and spread of invasive species. Over the past 50 years, there has been a gradual shift away from large and medium scale federal/state single-agency-led weed eradication programs in the United States, to smaller interagency-led projects involving impacted and potential stakeholders. The importance of volunteer weed spotters in detecting and reporting suspected new invasive species has also been recognized in recent years.

  17. Early detection of materials degradation

    NASA Astrophysics Data System (ADS)

    Meyendorf, Norbert

    2017-02-01

    Lightweight components for transportation and aerospace applications are designed for an estimated lifecycle, taking expected mechanical and environmental loads into account. The main reason for catastrophic failure of components within the expected lifecycle are material inhomogeneities, like pores and inclusions as origin for fatigue cracks, that have not been detected by NDE. However, material degradation by designed or unexpected loading conditions or environmental impacts can accelerate the crack initiation or growth. Conventional NDE methods are usually able to detect cracks that are formed at the end of the degradation process, but methods for early detection of fatigue, creep, and corrosion are still a matter of research. For conventional materials ultrasonic, electromagnetic, or thermographic methods have been demonstrated as promising. Other approaches are focused to surface damage by using optical methods or characterization of the residual surface stresses that can significantly affect the creation of fatigue cracks. For conventional metallic materials, material models for nucleation and propagation of damage have been successfully applied for several years. Material microstructure/property relations are well established and the effect of loading conditions on the component life can be simulated. For advanced materials, for example carbon matrix composites or ceramic matrix composites, the processes of nucleation and propagation of damage is still not fully understood. For these materials NDE methods can not only be used for the periodic inspections, but can significantly contribute to the material scientific knowledge to understand and model the behavior of composite materials.

  18. Case study of early detection and intervention of infectious disease outbreaks in an institution using Nursery School Absenteeism Surveillance Systems (NSASSy) of the Public Health Center.

    PubMed

    Matsumoto, Kayo; Hirayama, Chifumi; Sakuma, Yoko; Itoi, Yoichi; Sunadori, Asami; Kitamura, Junko; Nakahashi, Takeshi; Sugawara, Tamie; Ohkusa, Yasushi

    2016-01-01

    Objectives Detecting outbreaks early and then activating countermeasures based on such information is extremely important for infection control at childcare facilities. The Sumida ward began operating the Nursery School Absenteeism Surveillance System (NSASSy) in August 2013, and has since conducted real-time monitoring at nursery schools. The Public Health Center can detect outbreaks early and support appropriate intervention. This paper describes the experiences of Sumida Public Health Center related to early detection and intervention since the initiation of the system.Methods In this study, we investigated infectious disease outbreaks detected at 62 nursery schools in the Sumida ward, which were equipped with NSASSy from early November 2013 through late March 2015. We classified the information sources of the detected outbreak and responses of the public health center. The sources were (1) direct contact from some nursery schools, (2) messages from public officers with jurisdiction over nursery schools, (3) automatic detection by NSASSy, and (4) manual detection by public health center officers using NSASSy. The responses made by the health center were described and classified into 11 categories including verification of outbreak and advice for caregivers.Results The number of outbreaks detected by the aforementioned four information sources was zero, 25, 15, and 7 events, respectively, during the first 5 months after beginning NSASSy. These numbers became 5, 7, 53, and 25 events, respectively, during the subsequent 12 months. The number of outbreaks detected increased by 47% during the first 5 months, and by 87% in the following 12 months. The responses were primarily confirming the situation and offering advice to caregivers.Conclusion The Sumida Public Health Center ward could achieve early detection with automatic or manual detection of NSASSy. This system recently has become an important detection resource, and has contributed greatly to early

  19. Early detection of congenital syphilis.

    PubMed

    Chowdhary, Nagalakshmi; Rani, Bs Kavya; Mukunda, K S; Kiran, N K

    2014-01-01

    Late congenital syphilis is a very rare clinical entity, and its early diagnosis and treatment is essential. Dental findings often provide valuable evidence for the diagnosis of late congenital syphilis. It occurs due to the transmission of the disease from an infected mother to her fetus through placenta. This long forgotten disease continues to effect pregnant women resulting in perinatal morbidity and mortality. Congenital syphilis is a preventable disease, and its presence reflects a failure of prenatal care delivery system, as well as syphilis control programs. We are reporting a case of late congenital syphilis with only Hutchinson's teeth.

  20. Preclinical Evaluation of a Decision Support Medical Monitoring System for Early Detection of Potential Hemodynamic Decompensation During Blood Loss in Humans

    DTIC Science & Technology

    2013-09-01

    Hemodynamic Decompensation During Blood Loss in Humans PRINCIPAL INVESTIGATOR: Michael J. Joyner, M.D. CONTRACTING ORGANIZATION: Mayo Clinic...Medical Monitoring System for Early Detection of Potential Hemodynamic Decompensation During Blood Loss in Humans 5c. PROGRAM ELEMENT NUMBER 6...loss and hemorrhage in humans. The aim Is to be able to detect subtle changes in hemodynamic variables that provide prodromal clues to Impending

  1. Early Detection | Division of Cancer Prevention

    Cancer.gov

    [[{"fid":"171","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Early Detection Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Early Detection Research Group Homepage Logo","field_folder[und]":"15"},"type":"media","field_deltas":{"1":{"format":"default","field_file_image_alt_text[und][0][value]":"Early

  2. Early esophageal cancer detection using RF classifiers

    NASA Astrophysics Data System (ADS)

    Janse, Markus H. A.; van der Sommen, Fons; Zinger, Svitlana; Schoon, Erik J.; de With, Peter H. N.

    2016-03-01

    Esophageal cancer is one of the fastest rising forms of cancer in the Western world. Using High-Definition (HD) endoscopy, gastroenterology experts can identify esophageal cancer at an early stage. Recent research shows that early cancer can be found using a state-of-the-art computer-aided detection (CADe) system based on analyzing static HD endoscopic images. Our research aims at extending this system by applying Random Forest (RF) classification, which introduces a confidence measure for detected cancer regions. To visualize this data, we propose a novel automated annotation system, employing the unique characteristics of the previous confidence measure. This approach allows reliable modeling of multi-expert knowledge and provides essential data for real-time video processing, to enable future use of the system in a clinical setting. The performance of the CADe system is evaluated on a 39-patient dataset, containing 100 images annotated by 5 expert gastroenterologists. The proposed system reaches a precision of 75% and recall of 90%, thereby improving the state-of-the-art results by 11 and 6 percentage points, respectively.

  3. Early Detection of Foot-And-Mouth Disease Virus from Infected Cattle Using A Dry Filter Air Sampling System.

    PubMed

    Pacheco, J M; Brito, B; Hartwig, E; Smoliga, G R; Perez, A; Arzt, J; Rodriguez, L L

    2017-04-01

    Foot-and-mouth disease (FMD) is a highly contagious livestock disease of high economic impact. Early detection of FMD virus (FMDV) is fundamental for rapid outbreak control. Air sampling collection has been demonstrated as a useful technique for detection of FMDV RNA in infected animals, related to the aerogenous nature of the virus. In the current study, air from rooms housing individual (n = 17) or two groups (n = 4) of cattle experimentally infected with FDMV A24 Cruzeiro of different virulence levels was sampled to assess the feasibility of applying air sampling as a non-invasive, screening tool to identify sources of FMDV infection. Detection of FMDV RNA in air was compared with first detection of clinical signs and FMDV RNA levels in serum and oral fluid. FMDV RNA was detected in room air samples 1-3 days prior (seven animals) or on the same day (four animals) as the appearance of clinical signs in 11 of 12 individually housed cattle. Only in one case clinical signs preceded detection in air samples by one day. Overall, viral RNA in oral fluid or serum preceded detection in air samples by 1-2 days. Six individually housed animals inoculated with attenuated strains did not show clinical signs, but virus was detected in air in one of these cases 3 days prior to first detection in oral fluid. In groups of four cattle housed together, air detection always preceded appearance of clinical signs by 1-2 days and coincided more often with viral shedding in oral fluid than virus in blood. These data confirm that air sampling is an effective non-invasive screening method for detecting FMDV infection in confined to enclosed spaces (e.g. auction barns, milking parlours). This technology could be a useful tool as part of a surveillance strategy during FMD prevention, control or eradication efforts. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  4. Contribution of Near Real Time MODIS-Based Forest Disturbance Detection Products to a National Forest Threat Early Warning System

    NASA Technical Reports Server (NTRS)

    Spruce, Joseph P.; Hargrove, William; Glasser, Jerry; Kuper, Philip D.

    2011-01-01

    This presentation discusses an effort to compute and post weekly MODIS forest change products for the conterminous US (CONUS), as part of national forest threat early warning system (EWS) known as the U.S. Forest Change Assessment Viewer (FCAV). The US Forest Service, NASA, USGS, and ORNL are working collaboratively to contribute weekly change products to this EWS. Large acreages of the nation's forests are being disturbed by a growing multitude of biotic and abiotic threats that can act either singularly or in combination. When common at regional scales, such disturbances can pose hazards and threats to floral and faunal bio-diversity, ecosystem sustainability, ecosystem services, and human settlements across the conterminous US. Regionally evident forest disturbances range from ephemeral periodic canopy defoliation to stand replacement mortality events due to insects, disease, fire, hurricanes, tornadoes, ice, hail, and drought. Mandated by the Healthy Forest Restoration Act of 2003, this forest threat EWS has been actively developed since 2006 and on-line since 2010. This FCAV system employs 250-meter MODIS NDVI-based forest change products as a key element of the system, providing regional and CONUS scale products in near real time every 8 days. Each forest change product in FCAV is based on current versus historical 24 day composite NDVI data gridded at 231.66 meter resolution. Current NDVI is derived from USGS eMODIS expedited products. MOD13 NDVI is used for constructing historical baselines. CONUS change products are computed for all forests as % change in the current versus historical NDVI. Change products are computed according to previous year, previous 3 years and previous 8 year historical baselines. The use of multiple baselines enables disturbance anomaly phenology to be more fully assessed. CONUS forest change products are posted each week on the FCAV, a web mapping service maintained by the National Environmental Modeling and Analysis Center. The

  5. Contribution of Near Real Time MODIS-Based Forest Disturbance Detection Products to a National Forest Threat Early Warning System

    NASA Astrophysics Data System (ADS)

    Spruce, J.; Hargrove, W. W.; Gasser, J.; Smoot, J.; Kuper, P.

    2011-12-01

    This presentation discusses an effort to compute and post weekly MODIS forest change products for the conterminous US (CONUS), as part of a web-based national forest threat early warning system (EWS) known as the U.S. Forest Change Assessment Viewer (FCAV). The US Forest Service, NASA, USGS, and ORNL are working collaboratively to contribute weekly change products to this EWS. Large acreages of the nation's forests are being disturbed by a growing multitude of biotic and abiotic threats that can act either singularly or in combination. When common at regional scales, such disturbances can pose hazards and threats to floral and faunal bio-diversity, ecosystem sustainability, ecosystem services, and human settlements across the conterminous US. Regionally evident forest disturbances range from ephemeral periodic canopy defoliation to stand replacement mortality events due to insects, disease, fire, hurricanes, tornadoes, ice, hail, and drought. Mandated by the Healthy Forest Restoration Act of 2003, this forest threat EWS has been actively developed since 2006 and on-line since 2010. The FCAV system employs 250-meter MODIS NDVI-based forest change products as a key element of the system, providing regional and CONUS scale products in near real time every 8 days. Each of our forest change products in FCAV is based on current versus historical 24 day composites of NDVI data gridded at 231.66 meter resolution. Current NDVI is derived from USGS eMODIS expedited products. MOD13 NDVI is used for constructing historical baselines. CONUS change products are computed for all forests as % change in the current versus historical NDVI for a given 24 day period. Change products are computed according to previous year, previous 3 year and previous 8 year historical baselines. The use of multiple baselines enables apparent forest disturbance anomalies to be more fully assessed. CONUS forest change products are posted each week on the FCAV, a web mapping service constructed and

  6. Interagency partnering for weed prevention--progress on development of a National Early Detection and Rapid Response System for Invasive Plants in the United States

    Westbrooks, R.; Westbrooks, R.

    2011-01-01

    Over the past 50 years, experience has shown that interagency groups provide an effective forum for addressing various invasive species issues and challenges on multiple land units. However, more importantly, they can also provide a coordinated framework for early detection, reporting, identification and vouchering, rapid assessment, and rapid response to new and emerging invasive plants in the United States. Interagency collaboration maximizes the use of available expertise, resources, and authority for promoting early detection and rapid response (EDRR) as the preferred management option for addressing new and emerging invasive plants. Currently, an interagency effort is underway to develop a National EDRR System for Invasive Plants in the United States. The proposed system will include structural and informational elements. Structural elements of the system include a network of interagency partner groups to facilitate early detection and rapid response to new invasive plants, including the Federal Interagency Committee for the Management of Noxious and Exotic Weeds (FICMNEW), State Invasive Species Councils, State Early Detection and Rapid Response Coordinating Committees, State Volunteer Detection and Reporting Networks, Invasive Plant Task Forces, and Cooperative Weed Management Areas. Informational elements and products being developed include Regional Invasive Plant Atlases, and EDRR Guidelines for EDRR Volunteer Network Training, Rapid Assessment and Rapid Response, and Criteria for Selection of EDRR Species. System science and technical support elements which are provided by cooperating state and federal scientists, include EDRR guidelines, training curriculum for EDRR volunteers and agency field personnel, plant identification and vouchering, rapid assessments, as well as predictive modeling and ecological range studies for invasive plant species.

  7. Randomized trial of a home monitoring system for early detection of choroidal neovascularization home monitoring of the Eye (HOME) study.

    PubMed

    Chew, Emily Y; Clemons, Traci E; Bressler, Susan B; Elman, Michael J; Danis, Ronald P; Domalpally, Amitha; Heier, Jeffrey S; Kim, Judy E; Garfinkel, Richard

    2014-02-01

    achieved statistical significance, with the participants in the device arm demonstrating a smaller decline in visual acuity with fewer letters lost from baseline to CNV detection (median, -4 letters; interquartile range [IQR], -11.0 to -1.0 letters) compared with standard care (median, -9 letters; IQR, -14.0 to -4.0 letters; P = 0.021), resulting in better visual acuity at CNV detection in the device arm. The Data and Safety Monitoring Committee recommended early study termination for efficacy. Persons at high risk for CNV developing benefit from the home monitoring strategy for earlier detection of CNV development, which increases the likelihood of better visual acuity results after intravitreal anti-VEGF therapy. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  8. Early Childhood Systems: Transforming Early Learning

    ERIC Educational Resources Information Center

    Kagan, Sharon Lynn, Ed.; Kauertz, Kristie, Ed.

    2012-01-01

    In this seminal volume, leading authorities strategize about how to create early childhood systems that transcend politics and economics to serve the needs of all young children. The authors offer different interpretations of the nature of early childhood systems, discuss the elements necessary to support their development, and examine how…

  9. BEAP profiles as rapid test system for status analysis and early detection of process incidents in biogas plants.

    PubMed

    Refai, Sarah; Berger, Stefanie; Wassmann, Kati; Hecht, Melanie; Dickhaus, Thomas; Deppenmeier, Uwe

    2017-03-01

    A method was developed to quantify the performance of microorganisms involved in different digestion levels in biogas plants. The test system was based on the addition of butyrate (BCON), ethanol (ECON), acetate (ACON) or propionate (PCON) to biogas sludge samples and the subsequent analysis of CH 4 formation in comparison to control samples. The combination of the four values was referred to as BEAP profile. Determination of BEAP profiles enabled rapid testing of a biogas plant's metabolic state within 24 h and an accurate mapping of all degradation levels in a lab-scale experimental setup. Furthermore, it was possible to distinguish between specific BEAP profiles for standard biogas plants and for biogas reactors with process incidents (beginning of NH 4 + -N inhibition, start of acidification, insufficient hydrolysis and potential mycotoxin effects). Finally, BEAP profiles also functioned as a warning system for the early prediction of critical NH 4 + -N concentrations leading to a drop of CH 4 formation.

  10. Evaluating the cost implications of a radio frequency identification feeding system for early detection of bovine respiratory disease in feedlot cattle.

    PubMed

    Wolfger, Barbara; Manns, Braden J; Barkema, Herman W; Schwartzkopf-Genswein, Karen S; Dorin, Craig; Orsel, Karin

    2015-03-01

    New technologies to identify diseased feedlot cattle in early stages of illness have been developed to reduce costs and welfare impacts associated with bovine respiratory disease (BRD). However, the economic value of early BRD detection has never been assessed. The objective was to simulate cost differences between two BRD detection methods during the first 61 d on feed (DOF) applied in moderate- to large-sized feedlots using an automated recording system (ARS) for feeding behavior and the current industry standard, pen-checking (visual appraisal confirmed by rectal temperature). Economic impact was assessed with a cost analysis in a simple decision model. Scenarios for Canadian and US feedlots with high- and low-risk cattle were modeled, and uncertainty was estimated using extensive sensitivity analyses. Input costs and probabilities were mainly extracted from publicly accessible market observations and a large-scale US feedlot study. In the baseline scenario, we modeled high-risk cattle with a treatment rate of 20% within the first 61 DOF in a feedlot of >8000 cattle in Canada. Early BRD detection was estimated to result in a relative risk of 0.60 in retreatment and 0.66 in mortality compared to pen-checking (based on previously published estimates). The additional cost of monitoring health with ARS in Canadian dollar (CAD) was 13.68 per steer. Scenario analysis for similar sized US feedlots and low-risk cattle with a treatment rate of 8% were included to account for variability in costs and probabilities in various cattle populations. Considering the cost of monitoring, all relevant treatment costs and sale price, ARS was more costly than visual appraisal during the first 61 DOF by CAD 9.61 and CAD 9.69 per steer in Canada and the US, respectively. This cost difference increased in low-risk cattle in Canada to CAD 12.45. Early BRD detection with ARS became less expensive if the costs for the system decreased to less than CAD 4.06/steer, or if the underlying true

  11. Early Detection of Sporadic Pancreatic Cancer

    PubMed Central

    Chari, Suresh T.; Kelly, Kimberly; Hollingsworth, Michael A.; Thayer, Sarah P.; Ahlquist, David A.; Andersen, Dana K.; Batra, Surinder K.; Brentnall, Teresa A.; Canto, Marcia; Cleeter, Deborah F.; Firpo, Matthew A.; Gambhir, Sanjiv Sam; Go, Vay Liang W.; Hines, O. Joe; Kenner, Barbara J.; Klimstra, David S.; Lerch, Markus M.; Levy, Michael J.; Maitra, Anirban; Mulvihill, Sean J.; Petersen, Gloria M.; Rhim, Andrew D.; Simeone, Diane M.; Srivastava, Sudhir; Tanaka, Masao; Vinik, Aaron I.; Wong, David

    2015-01-01

    Abstract Pancreatic cancer (PC) is estimated to become the second leading cause of cancer death in the United States by 2020. Early detection is the key to improving survival in PC. Addressing this urgent need, the Kenner Family Research Fund conducted the inaugural Early Detection of Sporadic Pancreatic Cancer Summit Conference in 2014 in conjunction with the 45th Anniversary Meeting of the American Pancreatic Association and Japan Pancreas Society. This seminal convening of international representatives from science, practice, and clinical research was designed to facilitate challenging interdisciplinary conversations to generate innovative ideas leading to the creation of a defined collaborative strategic pathway for the future of the field. An in-depth summary of current efforts in the field, analysis of gaps in specific areas of expertise, and challenges that exist in early detection is presented within distinct areas of inquiry: Case for Early Detection: Definitions, Detection, Survival, and Challenges; Biomarkers for Early Detection; Imaging; and Collaborative Studies. In addition, an overview of efforts in familial PC is presented in an addendum to this article. It is clear from the summit deliberations that only strategically designed collaboration among investigators, institutions, and funders will lead to significant progress in early detection of sporadic PC. PMID:25931254

  12. Kidney Disease: Early Detection and Treatment

    MedlinePlus

    ... Bar Home Current Issue Past Issues Special Section Kidney Disease: Early Detection and Treatment Past Issues / Winter ... called a "urine albumin-to-creatinine ratio." Treating Kidney Disease Kidney disease is usually a progressive disease, ...

  13. Colorectal Cancer: The Importance of Early Detection

    MedlinePlus

    ... of this page please turn JavaScript on. Feature: Colorectal Cancer The Importance of Early Detection Past Issues / Summer ... Cancer of the colon or rectum is called colorectal cancer. The colon and the rectum are part of ...

  14. Early detection of contagious diseases

    DOEpatents

    Colston, Jr., Billy W.; Milanovich, Fred P [Lafayette, CA; Estacio, Pedro [Mission San Jose, CA; Chang, John [Walnut Creek, CA

    2011-08-09

    This invention provides an electronic proximity apparatus and a surveillance method using such an apparatus for alerting individuals that are exposed to a contagious disease. When a person becomes symptomatic and is diagnosed as positive for a given contagious agent, individuals that have recently maintained a threshold proximity with respect to an infected individual are notified and advised to seek immediate medial care. Treatment of individuals in the very early phases of infection (pre-symptomatic) significantly reduces contagiousness of the infected population first exposed to the contagious disease, thus preventing spread of the disease throughout the general population.

  15. WE-EF-210-07: Development of a Minimally Invasive Photo Acoustic Imaging System for Early Prostate Cancer Detection

    SciT

    Sano, M; Yousefi, S; Xing, L

    Purpose: The objective of this work is to design, implement and characterize a catheter-based ultrasound/photoacoustic imaging probe for early-diagnosis of prostate cancer and to aid in image-guided radiation therapy. Methods: The need to image across 6–10cm of tissue to image the whole prostate gland limits the resolution achievable with a transrectal ultrasound approach. In contrast, the urethra bisects the prostate gland, providing a minimally invasive pathway for deploying a high resolution ultrasound transducer. Utilizing a high-frequency (20MHz) ultrasound/photoacoustic probe, high-resolution structural and molecular imaging of the prostate tissue is possible. A custom 3D printed probe containing a high-frequency single-element ultrasoundmore » transducer is utilized. The diameter of the probe is designed to fit inside a Foley catheter and the probe is rotated around the central axis to achieve a circular B-scan. A custom ultrasound amplifier and receiver was set up to trigger the ultrasound pulse transmission and record the reflected signal. The reconstructed images were compared to images generated by traditional 5 MHz ultrasound transducers. Results: The preliminary results using the high-frequency ultrasound probe show that it is possible to resolve finely detailed information in a prostate tissue phantom that was not achievable with previous low-frequency ultrasound systems. Preliminary ultrasound imaging was performed on tissue mimicking phantom and sensitivity and signal-to-noise ratio of the catheter was measured. Conclusion: In order to achieve non-invasive, high-resolution, structural and molecular imaging for early-diagnosis and image-guided radiation therapy of the prostate tissue, a transurethral catheter was designed. Structural/molecular imaging using ultrasound/photoacoustic of the prostate tissue will allow for localization of hyper vascularized areas for early-stage prostate cancer diagnosis.« less

  16. Gastrointestinal Cancers: Screening and Early Detection.

    PubMed

    Griffin-Sobel, Joyce P

    2017-05-01

    To present an overview of current practices in the screening and early detection of gastrointestinal cancers. Literature reviews. Screening for gastrointestinal cancers is less than desirable, particularly in underserved populations. There are inadequate methods of screening for early detection of esophageal and gastric cancers. Education of patients is needed to reinforce the importance of screening for gastrointestinal cancers. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. FluDetWeb: an interactive web-based system for the early detection of the onset of influenza epidemics.

    PubMed

    Conesa, David; López-Quílez, Antonio; Martínez-Beneito, Miguel Angel; Miralles, María Teresa; Verdejo, Francisco

    2009-07-29

    The early identification of influenza outbreaks has became a priority in public health practice. A large variety of statistical algorithms for the automated monitoring of influenza surveillance have been proposed, but most of them require not only a lot of computational effort but also operation of sometimes not-so-friendly software. In this paper, we introduce FluDetWeb, an implementation of a prospective influenza surveillance methodology based on a client-server architecture with a thin (web-based) client application design. Users can introduce and edit their own data consisting of a series of weekly influenza incidence rates. The system returns the probability of being in an epidemic phase (via e-mail if desired). When the probability is greater than 0.5, it also returns the probability of an increase in the incidence rate during the following week. The system also provides two complementary graphs. This system has been implemented using statistical free-software (R and WinBUGS), a web server environment for Java code (Tomcat) and a software module created by us (Rdp) responsible for managing internal tasks; the software package MySQL has been used to construct the database management system. The implementation is available on-line from: http://www.geeitema.org/meviepi/fludetweb/. The ease of use of FluDetWeb and its on-line availability can make it a valuable tool for public health practitioners who want to obtain information about the probability that their system is in an epidemic phase. Moreover, the architecture described can also be useful for developers of systems based on computationally intensive methods.

  18. FluDetWeb: an interactive web-based system for the early detection of the onset of influenza epidemics

    PubMed Central

    2009-01-01

    Background The early identification of influenza outbreaks has became a priority in public health practice. A large variety of statistical algorithms for the automated monitoring of influenza surveillance have been proposed, but most of them require not only a lot of computational effort but also operation of sometimes not-so-friendly software. Results In this paper, we introduce FluDetWeb, an implementation of a prospective influenza surveillance methodology based on a client-server architecture with a thin (web-based) client application design. Users can introduce and edit their own data consisting of a series of weekly influenza incidence rates. The system returns the probability of being in an epidemic phase (via e-mail if desired). When the probability is greater than 0.5, it also returns the probability of an increase in the incidence rate during the following week. The system also provides two complementary graphs. This system has been implemented using statistical free-software (ℝ and WinBUGS), a web server environment for Java code (Tomcat) and a software module created by us (Rdp) responsible for managing internal tasks; the software package MySQL has been used to construct the database management system. The implementation is available on-line from: http://www.geeitema.org/meviepi/fludetweb/. Conclusion The ease of use of FluDetWeb and its on-line availability can make it a valuable tool for public health practitioners who want to obtain information about the probability that their system is in an epidemic phase. Moreover, the architecture described can also be useful for developers of systems based on computationally intensive methods. PMID:19640304

  19. Transcriptional response of peripheral lymphocytes to early fibrosarcoma: a model system for cancer detection based on hybridization signatures.

    PubMed

    Marques, Márcia M C; Junta, Cristina M; Zárate-Blades, Carlos R; Sakamoto-Hojo, Elza Tiemi; Donadi, Eduardo A; Passos, Geraldo A S

    2009-07-01

    Since circulating leukocytes, mainly B and T cells, continuously maintain vigilant and comprehensive immune surveillance, these cells could be used as reporters for signs of infection or other pathologies, including cancer. Activated lymphocyte clones trigger a sensitive transcriptional response, which could be identified by gene expression profiling. To assess this hypothesis, we conducted microarray analysis of the gene expression profile of lymphocytes isolated from immunocompetent BALB/c mice subcutaneously injected with different numbers of tumorigenic B61 fibrosarcoma cells. Flow cytometry demonstrated that the number of circulating T (CD3(+)CD4(+) or CD3(+)CD8(+)) or B (CD19(+)) cells did not change. However, the lymphocytes isolated from tumor cell-injected animals expressed a unique transcriptional profile that was identifiable before the development of a palpable tumor mass. This finding demonstrates that the transcriptional response appears before alterations in the main lymphocyte subsets and that the gene expression profile of peripheral lymphocytes can serve as a sensitive and accurate method for the early detection of cancer.

  20. Contribution of Near Real Time MODIS-Based Forest Disturbance Detection Products to a National Forest Threat Early Warning System

    NASA Technical Reports Server (NTRS)

    Spruce, Joseph; Hargrove, William; Gasser, Gerald; Smoot, James; Kuper, Philip

    2011-01-01

    U.S. forests occupy approx. 751 million acres (approx. 1/3 of total land). These forests are exposed to multiple biotic and abiotic threats that collectively damage extensive acreages each year. Hazardous forest disturbances can threaten human life and property, bio-diversity and water supplies. Timely regional forest monitoring products are needed to aid forest management and decision making by the US Forest Service and its state and private partners. Daily MODIS data products provide a means to monitor regional forest disturbances on a weekly basis. In response, we began work in 2006 to develop a Near Real Time (NRT) forest monitoring capability, based on MODIS NDVI data, as part of a national forest threat early warning system (EWS)

  1. Detection of Deteriorating Patients on Surgical Wards Outside the ICU by an Automated MEWS-Based Early Warning System With Paging Functionality.

    PubMed

    Heller, Axel R; Mees, Sören T; Lauterwald, Benjamin; Reeps, Christian; Koch, Thea; Weitz, Jürgen

    2018-05-16

    The establishment of early warning systems in hospitals was strongly recommended in recent guidelines to detect deteriorating patients early and direct them to adequate care. Upon reaching predefined trigger criteria, Medical Emergency Teams (MET) should be notified and directed to these patients. The present study analyses the effect of introducing an automated multiparameter early warning score (MEWS)-based early warning system with paging functionality on 2 wards hosting patients recovering from highly complex surgical interventions. The deployment of the system was accompanied by retrospective data acquisition during 12 months (intervention) using 4 routine databases: Hospital patient data management, anesthesia database, local data of the German Resuscitation Registry, and measurement logs of the deployed system (intervention period only). A retrospective 12-month data review using the same aforementioned databases before the deployment of the system served as control. Control and intervention phases were separated by a 6-month washout period for the installation of the system and for training. Data from 3827 patients could be acquired from 2 surgical wards during the two 12-month periods, 1896 patients in the control and 1931 in the intervention cohorts. Patient characteristics differed between the 2 observation phases. American Society of Anesthesiologists risk classification and duration of surgery as well as German DRG case-weight were significantly higher in the intervention period. However, the rate of cardiac arrests significantly dropped from 5.3 to 2.1 per 1000 admissions in the intervention period (P < 0.001). This observation was paralleled by a reduction of unplanned ICU admissions from 3.6% to 3.0% (P < 0.001), and an increase of notifications of critical conditions to the ward surgeon. The primary triggers for MET activation were abnormal ECG alerts, specifically asystole (n = 5), and pulseless electric activity (n = 8). In concert with a well

  2. Portable modular detection system

    DOEpatents

    Brennan, James S [Rodeo, CA; Singh, Anup [Danville, CA; Throckmorton, Daniel J [Tracy, CA; Stamps, James F [Livermore, CA

    2009-10-13

    Disclosed herein are portable and modular detection devices and systems for detecting electromagnetic radiation, such as fluorescence, from an analyte which comprises at least one optical element removably attached to at least one alignment rail. Also disclosed are modular detection devices and systems having an integrated lock-in amplifier and spatial filter and assay methods using the portable and modular detection devices.

  3. Evaluation of Epidemic Intelligence Systems Integrated in the Early Alerting and Reporting Project for the Detection of A/H5N1 Influenza Events

    PubMed Central

    Barboza, Philippe; Vaillant, Laetitia; Mawudeku, Abla; Nelson, Noele P.; Hartley, David M.; Madoff, Lawrence C.; Linge, Jens P.; Collier, Nigel; Brownstein, John S.; Yangarber, Roman; Astagneau, Pascal; on behalf of the Early Alerting, Reporting Project of the Global Health Security Initiative

    2013-01-01

    The objective of Web-based expert epidemic intelligence systems is to detect health threats. The Global Health Security Initiative (GHSI) Early Alerting and Reporting (EAR) project was launched to assess the feasibility and opportunity for pooling epidemic intelligence data from seven expert systems. EAR participants completed a qualitative survey to document epidemic intelligence strategies and to assess perceptions regarding the systems performance. Timeliness and sensitivity were rated highly illustrating the value of the systems for epidemic intelligence. Weaknesses identified included representativeness, completeness and flexibility. These findings were corroborated by the quantitative analysis performed on signals potentially related to influenza A/H5N1 events occurring in March 2010. For the six systems for which this information was available, the detection rate ranged from 31% to 38%, and increased to 72% when considering the virtual combined system. The effective positive predictive values ranged from 3% to 24% and F1-scores ranged from 6% to 27%. System sensitivity ranged from 38% to 72%. An average difference of 23% was observed between the sensitivities calculated for human cases and epizootics, underlining the difficulties in developing an efficient algorithm for a single pathology. However, the sensitivity increased to 93% when the virtual combined system was considered, clearly illustrating complementarities between individual systems. The average delay between the detection of A/H5N1 events by the systems and their official reporting by WHO or OIE was 10.2 days (95% CI: 6.7–13.8). This work illustrates the diversity in implemented epidemic intelligence activities, differences in system's designs, and the potential added values and opportunities for synergy between systems, between users and between systems and users. PMID:23472077

  4. Evaluation of epidemic intelligence systems integrated in the early alerting and reporting project for the detection of A/H5N1 influenza events.

    PubMed

    Barboza, Philippe; Vaillant, Laetitia; Mawudeku, Abla; Nelson, Noele P; Hartley, David M; Madoff, Lawrence C; Linge, Jens P; Collier, Nigel; Brownstein, John S; Yangarber, Roman; Astagneau, Pascal

    2013-01-01

    The objective of Web-based expert epidemic intelligence systems is to detect health threats. The Global Health Security Initiative (GHSI) Early Alerting and Reporting (EAR) project was launched to assess the feasibility and opportunity for pooling epidemic intelligence data from seven expert systems. EAR participants completed a qualitative survey to document epidemic intelligence strategies and to assess perceptions regarding the systems performance. Timeliness and sensitivity were rated highly illustrating the value of the systems for epidemic intelligence. Weaknesses identified included representativeness, completeness and flexibility. These findings were corroborated by the quantitative analysis performed on signals potentially related to influenza A/H5N1 events occurring in March 2010. For the six systems for which this information was available, the detection rate ranged from 31% to 38%, and increased to 72% when considering the virtual combined system. The effective positive predictive values ranged from 3% to 24% and F1-scores ranged from 6% to 27%. System sensitivity ranged from 38% to 72%. An average difference of 23% was observed between the sensitivities calculated for human cases and epizootics, underlining the difficulties in developing an efficient algorithm for a single pathology. However, the sensitivity increased to 93% when the virtual combined system was considered, clearly illustrating complementarities between individual systems. The average delay between the detection of A/H5N1 events by the systems and their official reporting by WHO or OIE was 10.2 days (95% CI: 6.7-13.8). This work illustrates the diversity in implemented epidemic intelligence activities, differences in system's designs, and the potential added values and opportunities for synergy between systems, between users and between systems and users.

  5. Earth Observations for Early Detection of Agricultural Drought in Countries at Risk: Contributions of the Famine Early Warning Systems Network (FEWS NET) (Invited)

    NASA Astrophysics Data System (ADS)

    Verdin, J. P.; Rowland, J.; Senay, G. B.; Funk, C. C.; Budde, M. E.; Husak, G. J.; Jayanthi, H.

    2013-12-01

    The Group on Earth Observations' Global Agricultural Monitoring (GEOGLAM) implementation plan emphasizes the information needs of countries at risk of food insecurity emergencies. Countries in this category are often vulnerable to disruption of agricultural production due to drought, while at the same time they lack well developed networks of in-situ observations to support early drought detection. Consequently, it is vital that Earth observations by satellites supplement those available from surface stations. The USGS, in its role as a FEWS NET implementing partner, has recently developed a number of new applications of satellite observations for this purpose. (1) In partnership with the University of California, Santa Barbara, a 30+ year time series of gridded precipitation estimates (CHIRPS) has been developed by blending NOAA GridSat B1 geostationary thermal infrared imagery with station observations using robust geostatistical methods. The core data set consists of pentadal (5-daily) accumulations from 1981-2013 at 0.05 degree spatial resolution between +/- 50 degrees latitude. Validation has been recently completed, and applications for gridded crop water balance calculations and mapping the Standardized Precipitation Index are in development. (2) Actual evapotranspiration (ETa) estimates using MODIS Land Surface Temperature (LST) data at 1-km have been successfully demonstrated using the operational Simplified Surface Energy Balance model with 8-day composites from the LPDAAC. A new, next-day latency implementation using daily LST swath data from the NASA LANCE server is in development for all the crop growing regions of the world. This ETa processing chain follows in the footsteps of (3) the expedited production of MODIS 250-meter NDVI images every five days at USGS EROS, likewise using LANCE daily swath data as input since 2010. Coverage includes Africa, Central Asia, the Middle East, Central America, and the Caribbean. (4) A surface water point monitoring

  6. Challenges In Early Glaucoma Detection.

    PubMed

    Dervisevic, Edita; Pavljasevic, Suzana; Dervisevic, Almir; Kasumovic, Sanja Sefic

    2016-06-01

    Glaucoma is the most common optic neuropathy which is characterized by progressive loss of retinal ganglion cells, the excavation of the optic nerve head, associated with defects in the visual field. It is not a disease, but the final result of united and yet completely unidentified cellular and subcellular processes and effects of many factors responsible for changes in retinal ganglion cells leading to their accelerated apoptosis. This is a prospective-retrospective, comparative, randomized clinical trial that included 150 patients, 97 were female and 53 male. The age of patients ranged from 18 to 80 years. The highest degree of myopia in category of tilted optic discs had patients with large disc (4.05 + -0.65). Values of the degree of myopia have linearly declined in relation to the size of the oblique disc. The analysis of the results revealed that the subjects who had a higher degree of myopia associated with glaucoma had frequent parapapillar atrophy of alpha and beta zones. The highest percentage of subjects with parapapillar changes were in the group of patients who had other than glaucoma and myopia (62%), then in the group of patients with glaucoma only (56%). Previous studies on the relationship between myopia and open-angle glaucoma are based on the results of observational studies. However, according to recent findings, based on the available studies, the systematic approach to estimate the association between myopia and glaucoma does not exist. Disc Damage Likelihood Scale (DDLS) is a new system for assessing glaucomatous damage of the optic disc which strongly correlates with the degree of visual field loss.

  7. Early Detection of Sporadic Pancreatic Cancer

    PubMed Central

    Kenner, Barbara J.; Chari, Suresh T.; Cleeter, Deborah F.; Go, Vay Liang W.

    2015-01-01

    Abstract Innovation leading to significant advances in research and subsequent translation to clinical practice is urgently necessary in early detection of sporadic pancreatic cancer. Addressing this need, the Early Detection of Sporadic Pancreatic Cancer Summit Conference was conducted by Kenner Family Research Fund in conjunction with the 2014 American Pancreatic Association and Japan Pancreas Society Meeting. International interdisciplinary scientific representatives engaged in strategic facilitated conversations based on distinct areas of inquiry: Case for Early Detection: Definitions, Detection, Survival, and Challenges; Biomarkers for Early Detection; Imaging; and Collaborative Studies. Ideas generated from the summit have led to the development of a Strategic Map for Innovation built upon 3 components: formation of an international collaborative effort, design of an actionable strategic plan, and implementation of operational standards, research priorities, and first-phase initiatives. Through invested and committed efforts of leading researchers and institutions, philanthropic partners, government agencies, and supportive business entities, this endeavor will change the future of the field and consequently the survival rate of those diagnosed with pancreatic cancer. PMID:25938853

  8. Early detection: the impact of genomics.

    PubMed

    van Lanschot, M C J; Bosch, L J W; de Wit, M; Carvalho, B; Meijer, G A

    2017-08-01

    The field of genomics has shifted our view on disease development by providing insights in the molecular and functional processes encoded in the genome. In the case of cancer, many alterations in the DNA accumulate that enable tumor growth or even metastatic dissemination. Identification of molecular signatures that define different stages of progression towards cancer can enable early tumor detection. In this review, the impact of genomics will be addressed using early detection of colorectal cancer (CRC) as an example. Increased understanding of the adenoma-to-carcinoma progression has led to the discovery of several diagnostic biomarkers. This combined with technical advancements, has facilitated the development of molecular tests for non-invasive early CRC detection in stool and blood samples. Even though several tests have already made it to clinical practice, sensitivity and specificity for the detection of precancerous lesions still need improvement. Besides the diagnostic qualities, also the accuracy of the intermediate endpoint is an important issue on how the effectiveness of a novel test is perceived. Here, progression biomarkers may provide a more precise measure than the currently used morphologically based features. Similar developments in biomarker use for early detection have taken place in other cancer types.

  9. [Toward constructing a system for detecting and coping with senile dementia in early stages among community-dwelling older people].

    PubMed

    Fujiwara, Yoshinori; Amano, Hidenori; Mori, Setsuko; Watanabe, Shuichiro; Kumagai, Shu; Yoshida, Yuko; Kim, Jungnim; Takabayashi, Koji; Yoshida, Hiroto; Ishihara, Miyuki; Eguchi, Fusako; Fuse, Sumie; Morita, Masahiro; Nagai, Hiroko; Shinkai, Shoji

    2003-08-01

    To establish a community health care system for screening community-dwelling older people with mild cognitive decline (MCD) and early diagnosis by a medical specialist. Out of all the elderly residents aged 65 years and over living in Yoita town in 2000 (n = 1673), 1544 participated in the interview survey held at community halls or at home (92.3% response). They underwent a Mini-Mental State Examination (MMSE) for assessment of cognitive function and answered questionnaires covering socio-demographic, psychological, physical and medical, and social activity items (2000/11). We defined cognitive decline as an MMSE < or = 1 SD below the age-specific mean (n = 371). Out of a total eligible population of 332, 158 pairs of subjects and their proxies participated in a follow-up survey (2001/11). The subjects themselves underwent MMSE again, and were asked for complaints of memory-related problems. Proxies answered about functional capacity and memory-related problems of subjects, for which we assessed the level of dementia with the Clinical Dementia Rating (CDR). We established criteria for encouragement to undergo detailed examination by a medical specialist as follows. 1) MMSE scores < or = 1 SD below age-specific means at both baseline and follow-up surveys, or 2) CDR > or = 0.5, and 3) not due to mental retardation. Non-participants had significant higher MMSE scores but were younger in the follow-up survey. Out of 96 subjects eligible for the detailed examination, 47 participants showed a tendency for older age with lower MMSE scores or younger age with higher MMSE scores than the average in the follow-up survey. The detailed examinations confirmed dementia of Alzheimer's type in 22 and vascular dementia in 13 on DSM-IV or magnetic resonance imaging. During our screening, 8 community care saloons were opened and the number of facilities for older people with cognitive decline is increasing. To establish a community health care system to screen and cope with

  10. Early detection and monitoring of Malaria

    NASA Astrophysics Data System (ADS)

    Rahman, Md Z.; Roytman, Leonid; Kadik, Abdelhamid; Miller, Howard; Rosy, Dilara A.

    2015-05-01

    Global Earth Observation Systems of Systems (GEOSS) are bringing vital societal benefits to people around the globe. In this research article, we engage undergraduate students in the exciting area of space exploration to improve the health of millions of people globally. The goal of the proposed research is to place students in a learning environment where they will develop their problem solving skills in the context of a world crisis (e.g., malaria). Malaria remains one of the greatest threats to public health, particularly in developing countries. The World Health Organization has estimated that over one million die of Malaria each year, with more than 80% of these found in Sub-Saharan Africa. The mosquitoes transmit malaria. They breed in the areas of shallow surface water that are suitable to the mosquito and parasite development. These environmental factors can be detected with satellite imagery, which provide high spatial and temporal coverage of the earth's surface. We investigate on moisture, thermal and vegetation stress indicators developed from NOAA operational environmental satellite data. Using these indicators and collected epidemiological data, it is possible to produce a forecast system that can predict the risk of malaria for a particular geographical area with up to four months lead time. This valuable lead time information provides an opportunity for decision makers to deploy the necessary preventive measures (spraying, treated net distribution, storing medications and etc) in threatened areas with maximum effectiveness. The main objective of the proposed research is to study the effect of ecology on human health and application of NOAA satellite data for early detection of malaria.

  11. How to select a proper early warning threshold to detect infectious disease outbreaks based on the China infectious disease automated alert and response system (CIDARS).

    PubMed

    Wang, Ruiping; Jiang, Yonggen; Michael, Engelgau; Zhao, Genming

    2017-06-12

    China Centre for Diseases Control and Prevention (CDC) developed the China Infectious Disease Automated Alert and Response System (CIDARS) in 2005. The CIDARS was used to strengthen infectious disease surveillance and aid in the early warning of outbreak. The CIDARS has been integrated into the routine outbreak monitoring efforts of the CDC at all levels in China. Early warning threshold is crucial for outbreak detection in the CIDARS, but CDCs at all level are currently using thresholds recommended by the China CDC, and these recommended thresholds have recognized limitations. Our study therefore seeks to explore an operational method to select the proper early warning threshold according to the epidemic features of local infectious diseases. The data used in this study were extracted from the web-based Nationwide Notifiable Infectious Diseases Reporting Information System (NIDRIS), and data for infectious disease cases were organized by calendar week (1-52) and year (2009-2015) in Excel format; Px was calculated using a percentile-based moving window (moving window [5 week*5 year], x), where x represents one of 12 centiles (0.40, 0.45, 0.50….0.95). Outbreak signals for the 12 Px were calculated using the moving percentile method (MPM) based on data from the CIDARS. When the outbreak signals generated by the 'mean + 2SD' gold standard were in line with a Px generated outbreak signal for each week during the year of 2014, this Px was then defined as the proper threshold for the infectious disease. Finally, the performance of new selected thresholds for each infectious disease was evaluated by simulated outbreak signals based on 2015 data. Six infectious diseases were selected in this study (chickenpox, mumps, hand foot and mouth diseases (HFMD), scarlet fever, influenza and rubella). Proper thresholds for chickenpox (P75), mumps (P80), influenza (P75), rubella (P45), HFMD (P75), and scarlet fever (P80) were identified. The selected proper thresholds for these

  12. Neonatal Jaundice Detection System.

    PubMed

    Aydın, Mustafa; Hardalaç, Fırat; Ural, Berkan; Karap, Serhat

    2016-07-01

    Neonatal jaundice is a common condition that occurs in newborn infants in the first week of life. Today, techniques used for detection are required blood samples and other clinical testing with special equipment. The aim of this study is creating a non-invasive system to control and to detect the jaundice periodically and helping doctors for early diagnosis. In this work, first, a patient group which is consisted from jaundiced babies and a control group which is consisted from healthy babies are prepared, then between 24 and 48 h after birth, 40 jaundiced and 40 healthy newborns are chosen. Second, advanced image processing techniques are used on the images which are taken with a standard smartphone and the color calibration card. Segmentation, pixel similarity and white balancing methods are used as image processing techniques and RGB values and pixels' important information are obtained exactly. Third, during feature extraction stage, with using colormap transformations and feature calculation, comparisons are done in RGB plane between color change values and the 8-color calibration card which is specially designed. Finally, in the bilirubin level estimation stage, kNN and SVR machine learning regressions are used on the dataset which are obtained from feature extraction. At the end of the process, when the control group is based on for comparisons, jaundice is succesfully detected for 40 jaundiced infants and the success rate is 85 %. Obtained bilirubin estimation results are consisted with bilirubin results which are obtained from the standard blood test and the compliance rate is 85 %.

  13. Detection of early caries by laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Sasazawa, Shuhei; Kakino, Satoko; Matsuura, Yuji

    2015-07-01

    To improve sensitivity of dental caries detection by laser-induced breakdown spectroscopy (LIBS) analysis, it is proposed to utilize emission peaks in the ultraviolet. We newly focused on zinc whose emission peaks exist in ultraviolet because zinc exists at high concentration in the outer layer of enamel. It was shown that by using ratios between heights of an emission peak of Zn and that of Ca, the detection sensitivity and stability are largely improved. It was also shown that early caries are differentiated from healthy part by properly setting a threshold in the detected ratios. The proposed caries detection system can be applied to dental laser systems such as ones based on Er:YAG-lasers. When ablating early caries part by laser light, the system notices the dentist that the ablation of caries part is finished. We also show the intensity of emission peaks of zinc decreased with ablation with Er:YAG laser light.

  14. Weather-based prediction of Plasmodium falciparum malaria in epidemic-prone regions of Ethiopia II. Weather-based prediction systems perform comparably to early detection systems in identifying times for interventions.

    PubMed

    Teklehaimanot, Hailay D; Schwartz, Joel; Teklehaimanot, Awash; Lipsitch, Marc

    2004-11-19

    Timely and accurate information about the onset of malaria epidemics is essential for effective control activities in epidemic-prone regions. Early warning methods that provide earlier alerts (usually by the use of weather variables) may permit control measures to interrupt transmission earlier in the epidemic, perhaps at the expense of some level of accuracy. Expected case numbers were modeled using a Poisson regression with lagged weather factors in a 4th-degree polynomial distributed lag model. For each week, the numbers of malaria cases were predicted using coefficients obtained using all years except that for which the prediction was being made. The effectiveness of alerts generated by the prediction system was compared against that of alerts based on observed cases. The usefulness of the prediction system was evaluated in cold and hot districts. The system predicts the overall pattern of cases well, yet underestimates the height of the largest peaks. Relative to alerts triggered by observed cases, the alerts triggered by the predicted number of cases performed slightly worse, within 5% of the detection system. The prediction-based alerts were able to prevent 10-25% more cases at a given sensitivity in cold districts than in hot ones. The prediction of malaria cases using lagged weather performed well in identifying periods of increased malaria cases. Weather-derived predictions identified epidemics with reasonable accuracy and better timeliness than early detection systems; therefore, the prediction of malarial epidemics using weather is a plausible alternative to early detection systems.

  15. Health system barriers and enablers to early access to breast cancer screening, detection, and diagnosis: a global analysis applied to the MENA region.

    PubMed

    Bowser, D; Marqusee, H; El Koussa, M; Atun, R

    2017-11-01

    To identify barriers and enablers that impact access to early screening, detection, and diagnosis of breast cancer both globally and more specifically in the Middle East and North Africa (MENA) region (with a specific focus on Egypt, Jordan, Oman, Saudi Arabia, United Arab Emirates [UAE], and Kuwait) with a specific focus on the health system. A systematic review of literature. We conducted a systematic reviewing using the PRISMA methodology. We searched PubMed, Global Index Medicus, and EMBASE for studies on 'breast cancer', 'breast neoplasm,' or 'screening, early detection, and early diagnosis' as well as key words related to the following barriers: religion, culture, health literacy, lack of knowledge/awareness/understanding, attitudes, fatalism/fear, shame/embarrassment, and physician gender from January 1, 2000 until September 1, 2016. Two independent reviewers screened both titles and abstracts. The application of inclusion and exclusion criteria yielded a final list of articles. A conceptual framework was used to guide the thematic analysis and examine health system barriers and enablers to breast cancer screening at the broader macro health system level, at the health provider level, and the individual level. The analysis was conducted globally and in the MENA region. A total of 11,936 references were identified through the initial search strategy, of which 55 were included in the final thematic analysis. The results found the following barriers and enablers to access to breast cancer screening at the health system level, the health provider level, and the individual level: health system structures such as health insurance and care coordination systems, costs, time concerns, provider characteristics including gender of the provider, quality of care issues, medical concerns, and fear. In addition, the following seven barriers and enablers were identified at the health system or provider level as significantly impacting screening for breast cancer: (1) access

  16. Life detection systems.

    NASA Technical Reports Server (NTRS)

    Mitz, M. A.

    1972-01-01

    Some promising newer approaches for detecting microorganisms are discussed, giving particular attention to the integration of different methods into a single instrument. Life detection methods may be divided into biological, chemical, and cytological methods. Biological methods are based on the biological properties of assimilation, metabolism, and growth. Devices for the detection of organic materials are considered, taking into account an instrument which volatilizes, separates, and analyzes a sample sequentially. Other instrumental systems described make use of a microscope and the cytochemical staining principle.

  17. Idaho Explosive Detection System

    Klinger, Jeff

    2018-05-23

    Learn how INL researchers are making the world safer by developing an explosives detection system that can inspect cargo. For more information about INL security research, visit http://www.facebook.com/idahonationallaboratory

  18. System Detects Vibrational Instabilities

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr.

    1990-01-01

    Sustained vibrations at two critical frequencies trigger diagnostic response or shutdown. Vibration-analyzing electronic system detects instabilities of combustion in rocket engine. Controls pulse-mode firing of engine and identifies vibrations above threshold amplitude at 5.9 and/or 12kHz. Adapted to other detection and/or control schemes involving simultaneous real-time detection of signals above or below preset amplitudes at two or more specified frequencies. Potential applications include rotating machinery and encoders and decoders in security systems.

  19. Preliminary Results of a New Auxiliary Mechatronic Near-Field Radar System to 3D Mammography for Early Detection of Breast Cancer †

    PubMed Central

    Molaei, Ali; Obermeier, Richard; Westwood, Andrew; Martinez, Aida; Martinez Lorenzo, Jose Angel

    2018-01-01

    Accurate and early detection of breast cancer is of high importance, as it is directly associated with the patients’ overall well-being during treatment and their chances of survival. Uncertainties in current breast imaging methods can potentially cause two main problems: (1) missing newly formed or small tumors; and (2) false alarms, which could be a source of stress for patients. A recent study at the Massachusetts General Hospital (MGH) indicates that using Digital Breast Tomosynthesis (DBT) can reduce the number of false alarms, when compared to conventional mammography. Despite the image quality enhancement DBT provides, the accurate detection of cancerous masses is still limited by low radiological contrast (about 1%) between the fibro-glandular tissue and affected tissue at X-ray frequencies. In a lower frequency region, at microwave frequencies, the contrast is comparatively higher (about 10%) between the aforementioned tissues; yet, microwave imaging suffers from low spatial resolution. This work reviews conventional X-ray breast imaging and describes the preliminary results of a novel near-field radar imaging mechatronic system (NRIMS) that can be fused with the DBT, in a co-registered fashion, to combine the advantages of both modalities. The NRIMS consists of two antipodal Vivaldi antennas, an XY positioner, and an ethanol container, all of which are particularly designed based on the DBT physical specifications. In this paper, the independent performance of the NRIMS is assessed by (1) imaging a bearing ball immersed in sunflower oil and (2) computing the heat Specific Absorption Rate (SAR) due to the electromagnetic power transmitted into the breast. The preliminary results demonstrate that the system is capable of generating images of the ball. Furthermore, the SAR results show that the system complies with the standards set for human trials. As a result, a configuration based on this design might be suitable for use in realistic clinical

  20. Preliminary Results of a New Auxiliary Mechatronic Near-Field Radar System to 3D Mammography for Early Detection of Breast Cancer.

    PubMed

    Ghanbarzadeh Dagheyan, Ashkan; Molaei, Ali; Obermeier, Richard; Westwood, Andrew; Martinez, Aida; Martinez Lorenzo, Jose Angel

    2018-01-25

    Accurate and early detection of breast cancer is of high importance, as it is directly associated with the patients' overall well-being during treatment and their chances of survival. Uncertainties in current breast imaging methods can potentially cause two main problems: (1) missing newly formed or small tumors; and (2) false alarms, which could be a source of stress for patients. A recent study at the Massachusetts General Hospital (MGH) indicates that using Digital Breast Tomosynthesis (DBT) can reduce the number of false alarms, when compared to conventional mammography. Despite the image quality enhancement DBT provides, the accurate detection of cancerous masses is still limited by low radiological contrast (about 1%) between the fibro-glandular tissue and affected tissue at X-ray frequencies. In a lower frequency region, at microwave frequencies, the contrast is comparatively higher (about 10%) between the aforementioned tissues; yet, microwave imaging suffers from low spatial resolution. This work reviews conventional X-ray breast imaging and describes the preliminary results of a novel near-field radar imaging mechatronic system (NRIMS) that can be fused with the DBT, in a co-registered fashion, to combine the advantages of both modalities. The NRIMS consists of two antipodal Vivaldi antennas, an XY positioner, and an ethanol container, all of which are particularly designed based on the DBT physical specifications. In this paper, the independent performance of the NRIMS is assessed by (1) imaging a bearing ball immersed in sunflower oil and (2) computing the heat Specific Absorption Rate (SAR) due to the electromagnetic power transmitted into the breast. The preliminary results demonstrate that the system is capable of generating images of the ball. Furthermore, the SAR results show that the system complies with the standards set for human trials. As a result, a configuration based on this design might be suitable for use in realistic clinical

  1. Value of Microperimetry in Detecting Early Retinal Toxicity of Hydroxychloroquine in Children with Juvenile Systemic Lupus Erythematosus.

    PubMed

    Youssef, Maha M; El-Fayoumi, Dina; Sidky, Mohamed Karim; Hegazy, Ahmed I; Marzouk, Huda; Eltanamly, Rasha M

    2017-01-01

    To evaluate retinal sensitivity in children who are on hydroxychloroquine (HCQ) for systemic lupus erythematosus using microperimetry and compare the results with those of the Humphrey visual field (HVF) 10-2 and spectral-domain optical coherence tomography (SD-OCT). A case-control cross-sectional study including 19 patients (less than 18 years old) on HCQ for at least 5 years. Controls were 21 normal children. Participants underwent a complete ophthalmic examination, then were investigated using HVF 10-2, SD-OCT, and microperimetry. Ocular examination revealed no abnormalities. The overall mean microperimetry sensitivity of the patients (15.75 dB) was not significantly different from that of the controls (16.35 dB). The HVF 10-2 showed a significant difference in the mean deviation of the patients. Conclusions and Message: Microperimetry was not more revealing than HVF 10-2 and SD-OCT. Larger studies are required to compare the diagnostic accuracy of screening modalities of retinal toxicity in children on HCQ. © 2017 S. Karger AG, Basel.

  2. Method for early detection of infectious mononucleosis

    DOEpatents

    Willard, K.E.

    1982-08-10

    Early detection of infectious mononucleosis is carried out using a sample of human blood by isolating and identifying the presence of Inmono proteins in the sample from a two-dimensional protein map with the proteins being characterized by having isoelectric banding as measured in urea of about -16 to -17 with respect to certain isoelectric point standards and molecular mass of about 70 to 75 K daltons as measured in the presence of sodium dodecylsulfate containing polyacrylamide gels, the presence of the Inmono proteins being correlated with the existence of infectious mononucleosis.

  3. Early Detection and Mass Screening For Cancer

    PubMed Central

    Miller, A. B.

    1972-01-01

    The author reviews the evidence for the efficacy of early detection and mass screening programs in reducing morbidity and mortality from cancer. In cancer of the cervix, although screening reduces morbidity, we still do not have evidence for reduction in mortality. In cancer of the breast, one study suggests a reduction in mortality in the 50-59 year age group following screening by clinical examination and mammography. In other sites, especially lung, there is no evidence at present to support the adoption of mass screening programs. It is important that such programs should be carefully evaluated in the population, preferably in controlled studies. PMID:20468806

  4. Design Support of an Above Cap-rock Early Detection Monitoring System using Simulated Leakage Scenarios at the FutureGen2.0 Site

    DOE PAGES

    Williams, Mark D.; USA, Richland Washington; Vermuel, Vince R.; ...

    2014-12-31

    The FutureGen 2.0 Project will design and build a first-of-its-kind, near-zero emissions coal-fueled power plant with carbon capture and storage (CCS). To assess storage site performance and meet the regulatory requirements of the Class VI Underground Injection Control (UIC) Program for CO 2 Geologic Sequestration, the FutureGen 2.0 project will implement a suite of monitoring technologies designed to evaluate CO 2 mass balance and detect any unforeseen loss in CO 2 containment. The monitoring program will include direct monitoring of the reservoir, and early-leak-detection monitoring directly above the primary confining zone. This preliminary modeling study described here focuses on hypotheticalmore » leakage scenarios into the first permeable unit above the primary confining zone (Ironton Sandstone) and is used to support assessment of early-leak detection capabilities. Future updates of the model will be used to assess potential impacts on the lowermost underground source of drinking water (Saint Peter Sandstone) for a range of theoretical leakage scenarios. This preliminary modeling evaluation considers both pressure response and geochemical signals in the overlying Ironton Sandstone. This model is independent of the FutureGen 2.0 reservoir model in that it does not simulate caprock discontinuities, faults, or failure scenarios. Instead this modeling effort is based on theoretical, volumetric-rate based leakage scenarios. The scenarios include leakage of 1% of the total injected CO 2 mass, but spread out over different time periods (20, 100, and 500 years) with each case yielding a different mass flux (i.e., smaller mass fluxes for longer duration leakage cases]. A brine leakage scenario using a volumetric leakage similar to the 20 year 1% CO 2 case was also considered. A framework for the comparison of the various cases was developed based on the exceedance of selected pressure and geochemical thresholds at different distances from the point of leakage and

  5. Intruder detection system

    NASA Technical Reports Server (NTRS)

    Lee, R. D. (Inventor)

    1973-01-01

    An intruder detection system is described. The system contains a transmitter which sends a frequency modulated and amplitude modulated signal to a remote receiver in response to a geophone detector which responds to seismic impulses created by the intruder. The signal makes it possible for an operator to determine the number of intruders and the manner of movement.

  6. Portable pathogen detection system

    DOEpatents

    Colston, Billy W.; Everett, Matthew; Milanovich, Fred P.; Brown, Steve B.; Vendateswaran, Kodumudi; Simon, Jonathan N.

    2005-06-14

    A portable pathogen detection system that accomplishes on-site multiplex detection of targets in biological samples. The system includes: microbead specific reagents, incubation/mixing chambers, a disposable microbead capture substrate, and an optical measurement and decoding arrangement. The basis of this system is a highly flexible Liquid Array that utilizes optically encoded microbeads as the templates for biological assays. Target biological samples are optically labeled and captured on the microbeads, which are in turn captured on an ordered array or disordered array disposable capture substrate and then optically read.

  7. Solar system fault detection

    DOEpatents

    Farrington, R.B.; Pruett, J.C. Jr.

    1984-05-14

    A fault detecting apparatus and method are provided for use with an active solar system. The apparatus provides an indication as to whether one or more predetermined faults have occurred in the solar system. The apparatus includes a plurality of sensors, each sensor being used in determining whether a predetermined condition is present. The outputs of the sensors are combined in a pre-established manner in accordance with the kind of predetermined faults to be detected. Indicators communicate with the outputs generated by combining the sensor outputs to give the user of the solar system and the apparatus an indication as to whether a predetermined fault has occurred. Upon detection and indication of any predetermined fault, the user can take appropriate corrective action so that the overall reliability and efficiency of the active solar system are increased.

  8. Solar system fault detection

    DOEpatents

    Farrington, Robert B.; Pruett, Jr., James C.

    1986-01-01

    A fault detecting apparatus and method are provided for use with an active solar system. The apparatus provides an indication as to whether one or more predetermined faults have occurred in the solar system. The apparatus includes a plurality of sensors, each sensor being used in determining whether a predetermined condition is present. The outputs of the sensors are combined in a pre-established manner in accordance with the kind of predetermined faults to be detected. Indicators communicate with the outputs generated by combining the sensor outputs to give the user of the solar system and the apparatus an indication as to whether a predetermined fault has occurred. Upon detection and indication of any predetermined fault, the user can take appropriate corrective action so that the overall reliability and efficiency of the active solar system are increased.

  9. Early Detection and Intervention of ASD: A European Overview

    PubMed Central

    Narzisi, Antonio; García-Primo, Patricia; Kawa, Rafal

    2017-01-01

    Over the last several years there has been an increasing focus on early detection of Autism Spectrum Disorder (ASD), not only from the scientific field but also from professional associations and public health systems all across Europe. Not surprisingly, in order to offer better services and quality of life for both children with ASD and their families, different screening procedures and tools have been developed for early assessment and intervention. However, current evidence is needed for healthcare providers and policy makers to be able to implement specific measures and increase autism awareness in European communities. The general aim of this review is to address the latest and most relevant issues related to early detection and treatments. The specific objectives are (1) analyse the impact, describing advantages and drawbacks, of screening procedures based on standardized tests, surveillance programmes, or other observational measures; and (2) provide a European framework of early intervention programmes and practices and what has been learnt from implementing them in public or private settings. This analysis is then discussed and best practices are suggested to help professionals, health systems and policy makers to improve their local procedures or to develop new proposals for early detection and intervention programmes. PMID:29194420

  10. Subsurface Intrusion Detection System

    DTIC Science & Technology

    2014-02-25

    deployed along the boundary. The outputs of the vibration sensors are taken as an indication of underground activity and can therefore be used to...for detecting underground activity. The system has a first sensor located at a first depth below the surface of the ground and a second sensor...and the second sensor has a second output indicative of vibrations at the second depth. A processor adapted to detect underground activity compares

  11. Malignant external otitis: early scintigraphic detection

    SciT

    Strashun, A.M.; Nejatheim, M.; Goldsmith, S.J.

    1984-02-01

    Pseudomonas otitis externa in elderly diabetics may extend aggressively to adjacent bone, cranial nerves, meninges, and vessels, leading to a clinical diagnosis of ''malignant'' external otitis. Early diagnosis is necessary for successful treatment. This study compares the findings of initial radiographs, thin-section tomography of temporal bone, CT scans of head and neck, technetium-99m methylene diphosphonate (MDP) and gallium-67 citrate scintigraphy, and single-photon emission computed tomography (SPECT) for detection of temporal bone osteomylitis in ten patients fulfilling the clinical diagnostic criteria of malignant external otitis. Skull radiographs were negative in all of the eight patients studied. Thin-section tomography was positive inmore » one of the seven patients studied using this modality. CT scanning suggested osteomyelitis in three of nine patients. Both Tc-99m and Ga-67 citrate scintigraphy were positive in 10 of 10 patients. These results suggest that technetium and gallium scintigraphy are more sensitive than radiographs and CT scans for early detection of malignant external otitis.« less

  12. Biomarkers for early detection of Alzheimer disease.

    PubMed

    Barber, Robert C

    2010-09-01

    The existence of an effective biomarker for early detection of Alzheimer disease would facilitate improved diagnosis and stimulate therapeutic trials. Multidisciplinary clinical diagnosis of Alzheimer disease is time consuming and expensive and relies on experts who are rarely available outside of specialty clinics. Thus, many patients do not receive proper diagnosis until the disease has progressed beyond stages in which treatments are maximally effective. In the clinical trial setting, rapid, cost-effective screening of patients for Alzheimer disease is of paramount importance for the development of new treatments. Neuroimaging of cortical amyloid burden and volumetric changes in the brain and assessment of protein concentrations (eg, β-amyloid 1-42, total tau, phosphorylated tau) in cerebrospinal fluid are diagnostic tools that are not widely available. Known genetic markers do not provide sufficient discriminatory power between different forms of dementia to be useful in isolation. Recent studies using panels of biomarkers for diagnosis of Alzheimer disease or mild cognitive impairment have been promising, though no such studies have been cross-validated in independent samples of subjects. The ideal biomarker enabling early detection of Alzheimer disease has not yet been identified.

  13. Prevention and Early Detection of Prostate Cancer

    PubMed Central

    Cuzick, Jack; Thorat, Mangesh A.; Andriole, Gerald; Brawley, Otis W.; Brown, Powel H.; Culig, Zoran; Eeles, Rosalind A.; Ford, Leslie G.; Hamdy, Freddie C.; Holmberg, Lars; Ilic, Dragan; Key, Timothy J.; La Vecchia, Carlo; Lilja, Hans; Marberger, Michael; Meyskens, Frank L.; Minasian, Lori M.; Parker, Chris; Parnes, Howard L.; Perner, Sven; Rittenhouse, Harry; Schalken, Jack; Schmid, Hans-Peter; Schmitz-Dräger, Bernd J.; Schröder, Fritz H.; Stenzl, Arnulf; Tombal, Bertrand; Wilt, Timothy J.; Wolk, Alicja

    2014-01-01

    Prostate cancer is one of the most common cancers in men and the global burden of this disease is rising. Lifestyle modifications like smoking cessation, exercise and weight control offer opportunities to decrease the risk of developing prostate cancer. Early detection of prostate cancer by PSA screening remains controversial; yet, changes in PSA threshold, frequency of screening, and addition of other biomarkers have potential to minimise overdiagnosis associated with PSA screening. Several new biomarkers appear promising in individuals with elevated PSA levels or those diagnosed with prostate cancer, these are likely to guide in separating individuals who can be spared of aggressive treatment from those who need it. Several pharmacological agents like 5α-reductase inhibitors, aspirin etc. have a potential to prevent development of prostate cancer. In this review, we discuss the current evidence and research questions regarding prevention, early detection of prostate cancer and management of men either at high risk of prostate cancer or diagnosed with low-grade prostate cancer. PMID:25281467

  14. Results of an early hearing detection program.

    PubMed

    Borkoski Barreiro, Silvia A; Falcón González, Juan C; Bueno Yanes, Jorge; Pérez Bermúdez, José L; López Cano, Zoraida; Ramos Macías, Ángel

    2013-01-01

    Neonatal hearing loss is a public health problem that meets the requirements for submission to universal screening. Our objective was to analyse the results of the early hearing detection and intervention program implemented at our centre between January 2007 and December 2010. We studied 26,717 newborns during the period mentioned, using transient otoacoustic emissions (TOAEs) for the screening. The diagnostic phase was carried out at the hearing loss department. In our area, there were 27,935 births between January 2007 and December 2010. The screening was performed on 26,717 children. Of these, 24,173 had positive TOAEs, 1,040 had no TOAEs and 1,504 presented TOAEs in 1 ear with absence of TOAEs in the contralateral ear. Risk factors associated with hearing loss were found in 4,674 infants. In a second phase of the program, TOAEs were given to 5,156 children, of whom 4,626 had positive otoacoustic emissions in both ears, 323 had no TOAEs in 1 ear and 207 failed this second phase. Of all children studied, 3.8% were referred to auditory brainstem response (ABR) testing and 26 children entered the cochlear implant program. The program reached coverage of 95.64%. The early hearing detection and intervention program at our hospital is suitable for our environment, reaching 95.64% of coverage. We consider the relationship between effectiveness and efficiency to be positive. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  15. Life Detection on the Early Earth

    NASA Technical Reports Server (NTRS)

    Runnegar, B.

    2004-01-01

    Finding evidence for first the existence, and then the nature of life on the early Earth or early Mars requires both the recognition of subtle biosignatures and the elimination of false positives. The history of the search for fossils in increasingly older Precambrian strata illustrates these difficulties very clearly, and new observational and theoretical approaches are both needed and being developed. At the microscopic level of investigation, three-dimensional morphological characterization coupled with in situ chemical (isotopic, elemental, structural) analysis is the desirable first step. Geological context is paramount, as has been demonstrated by the controversies over AH84001, the Greenland graphites, and the Apex chert microfossils . At larger scales, the nature of sedimentary bedforms and the structures they display becomes crucial, and here the methods of condensed matter physics prove most useful in discriminating between biological and non-biological constructions. Ultimately, a combination of geochemical, morphological, and contextural evidence may be required for certain life detection on the early Earth or elsewhere.

  16. About the Early Detection Research Group | Division of Cancer Prevention

    Cancer.gov

    The Early Detection Research Group supports research that seeks to determine the effectiveness, operating characteristics and clinical impact (harms as well as benefits) of cancer early detection technologies and practices, such as imaging and molecular biomarker approaches.   The group ran two large-scale early detection trials for which data and biospecimens are available

  17. Liquid biopsy for lung cancer early detection

    PubMed Central

    Liguori, Alessia; D’Aveni, Alessandro; Karachaliou, Niki; Gonzalez-Cao, Maria; Daffinà, Maria Grazia; Lazzari, Chiara; Altavilla, Giuseppe; Rosell, Rafael

    2018-01-01

    Molecularly targeted therapies and immune checkpoint inhibitors have markedly improved the therapeutic management of advanced lung cancer. However, it still remains the leading cause of cancer-related mortality worldwide, with disease stage at diagnosis representing the main prognostic factor. Detection of lung cancer at an earlier stage of disease, potentially susceptible of curative resection, can be critical to improve patients survival. Low-dose computed tomography (LDCT) screening of high-risk patients has been demonstrated to reduce mortality from lung cancer, but can be also associated with high false-positive rate, thus often resulting in unnecessary interventions for patients. Novel sensitive and specific biomarkers for identification of high-risk subjects and early detection that can be used alternatively and/or complement current routine diagnostic procedures are needed. Liquid biopsy has recently demonstrated its clinical usefulness in advanced NSCLC as a surrogate of tissue biopsy for noninvasive assessment of specific genomic alterations, thereby providing prognostic and predictive information. Different biosources from liquid biopsy, including cell free circulating tumor DNA (ctDNA), circulating tumor cells (CTCs), exosomes and tumor-educated platelets (TEPs), have also been widely investigated for their potential role in lung cancer diagnosis. This review will provide an overview on the circulating biomarkers being evaluated for lung cancer detection, mainly focusing on results from most recent studies, the techniques developed to perform their assessment in blood and other biologic fluids and challenges in their clinical applications. PMID:29780635

  18. Liquid biopsy for lung cancer early detection.

    PubMed

    Santarpia, Mariacarmela; Liguori, Alessia; D'Aveni, Alessandro; Karachaliou, Niki; Gonzalez-Cao, Maria; Daffinà, Maria Grazia; Lazzari, Chiara; Altavilla, Giuseppe; Rosell, Rafael

    2018-04-01

    Molecularly targeted therapies and immune checkpoint inhibitors have markedly improved the therapeutic management of advanced lung cancer. However, it still remains the leading cause of cancer-related mortality worldwide, with disease stage at diagnosis representing the main prognostic factor. Detection of lung cancer at an earlier stage of disease, potentially susceptible of curative resection, can be critical to improve patients survival. Low-dose computed tomography (LDCT) screening of high-risk patients has been demonstrated to reduce mortality from lung cancer, but can be also associated with high false-positive rate, thus often resulting in unnecessary interventions for patients. Novel sensitive and specific biomarkers for identification of high-risk subjects and early detection that can be used alternatively and/or complement current routine diagnostic procedures are needed. Liquid biopsy has recently demonstrated its clinical usefulness in advanced NSCLC as a surrogate of tissue biopsy for noninvasive assessment of specific genomic alterations, thereby providing prognostic and predictive information. Different biosources from liquid biopsy, including cell free circulating tumor DNA (ctDNA), circulating tumor cells (CTCs), exosomes and tumor-educated platelets (TEPs), have also been widely investigated for their potential role in lung cancer diagnosis. This review will provide an overview on the circulating biomarkers being evaluated for lung cancer detection, mainly focusing on results from most recent studies, the techniques developed to perform their assessment in blood and other biologic fluids and challenges in their clinical applications.

  19. A Novel Early Warning System Based on a Sediment Microbial Fuel Cell for In Situ and Real Time Hexavalent Chromium Detection in Industrial Wastewater.

    PubMed

    Zhao, Shuai; Liu, Pu; Niu, Yongyan; Chen, Zhengjun; Khan, Aman; Zhang, Pengyun; Li, Xiangkai

    2018-02-22

    Hexavalent chromium (Cr(VI)) is a well-known toxic heavy metal in industrial wastewater, but in situ and real time monitoring cannot be achieved by current methods used during industrial wastewater treatment processes. In this study, a Sediment Microbial Fuel Cell (SMFC) was used as a biosensor for in situ real-time monitoring of Cr(VI), which was the organic substrate is oxidized in the anode and Cr(VI) is reduced at the cathode simultaneously. The pH 6.4 and temperature 25 °C were optimal conditions for the operation. Under the optimal conditions, linearity (R² = 0.9935) of the generated voltage was observed in the Cr(VI) concentration range from 0.2 to 0.7 mg/L. The system showed high specificity for Cr(VI), as other co-existing ions such as Cu 2+ , Zn 2+ , and Pb 2+ did not interfere with Cr(VI) detection. In addition, when the sediment MFC-based biosensor was applied for measuring Cr(VI) in actual wastewater samples, a low deviation (<8%) was obtained, which indicated its potential as a reliable biosensor device. MiSeq sequencing results showed that electrochemically active bacteria ( Geobacter and Pseudomonas ) were enriched at least two-fold on the biofilm of the anode in the biosensor as compared to the SMFC without Cr(VI). Cyclic voltammetry curves indicated that a pair of oxidation/reduction peaks appeared at -111 mV and 581 mV, respectively. These results demonstrated that the proposed sediment microbial fuel cell-based biosensor can be applied as an early warning device for real time in situ detection of Cr(VI) in industrial wastewaters.

  20. A Novel Early Warning System Based on a Sediment Microbial Fuel Cell for In Situ and Real Time Hexavalent Chromium Detection in Industrial Wastewater

    PubMed Central

    Zhao, Shuai; Liu, Pu; Niu, Yongyan; Chen, Zhengjun; Khan, Aman; Zhang, Pengyun; Li, Xiangkai

    2018-01-01

    Hexavalent chromium (Cr(VI)) is a well-known toxic heavy metal in industrial wastewater, but in situ and real time monitoring cannot be achieved by current methods used during industrial wastewater treatment processes. In this study, a Sediment Microbial Fuel Cell (SMFC) was used as a biosensor for in situ real-time monitoring of Cr(VI), which was the organic substrate is oxidized in the anode and Cr(VI) is reduced at the cathode simultaneously. The pH 6.4 and temperature 25 °C were optimal conditions for the operation. Under the optimal conditions, linearity (R2 = 0.9935) of the generated voltage was observed in the Cr(VI) concentration range from 0.2 to 0.7 mg/L. The system showed high specificity for Cr(VI), as other co-existing ions such as Cu2+, Zn2+, and Pb2+ did not interfere with Cr(VI) detection. In addition, when the sediment MFC-based biosensor was applied for measuring Cr(VI) in actual wastewater samples, a low deviation (<8%) was obtained, which indicated its potential as a reliable biosensor device. MiSeq sequencing results showed that electrochemically active bacteria (Geobacter and Pseudomonas) were enriched at least two-fold on the biofilm of the anode in the biosensor as compared to the SMFC without Cr(VI). Cyclic voltammetry curves indicated that a pair of oxidation/reduction peaks appeared at −111 mV and 581 mV, respectively. These results demonstrated that the proposed sediment microbial fuel cell-based biosensor can be applied as an early warning device for real time in situ detection of Cr(VI) in industrial wastewaters. PMID:29470394

  1. Implementing Obstetric Early Warning Systems.

    PubMed

    Friedman, Alexander M; Campbell, Mary L; Kline, Carolyn R; Wiesner, Suzanne; D'Alton, Mary E; Shields, Laurence E

    2018-04-01

    Severe maternal morbidity and mortality are often preventable and obstetric early warning systems that alert care providers of potential impending critical illness may improve maternal safety. While literature on outcomes and test characteristics of maternal early warning systems is evolving, there is limited guidance on implementation. Given current interest in early warning systems and their potential role in care, the 2017 Society for Maternal-Fetal Medicine (SMFM) Annual Meeting dedicated a session to exploring early warning implementation across a wide range of hospital settings. This manuscript reports on key points from this session. While implementation experiences varied based on factors specific to individual sites, common themes relevant to all hospitals presenting were identified. Successful implementation of early warnings systems requires administrative and leadership support, dedication of resources, improved coordination between nurses, providers, and ancillary staff, optimization of information technology, effective education, evaluation of and change in hospital culture and practices, and support in provider decision-making. Evolving data on outcomes on early warning systems suggest that maternal risk may be reduced. To effectively reduce maternal, risk early warning systems that capture deterioration from a broad range of conditions may be required in addition to bundles tailored to specific conditions such as hemorrhage, thromboembolism, and hypertension.

  2. Water system virus detection

    NASA Technical Reports Server (NTRS)

    Fraser, A. S.; Wells, A. F.; Tenoso, H. J.

    1975-01-01

    A monitoring system developed to test the capability of a water recovery system to reject the passage of viruses into the recovered water is described. A nonpathogenic marker virus, bacteriophage F2, is fed into the process stream before the recovery unit and the reclaimed water is assayed for its presence. Detection of the marker virus consists of two major components, concentration and isolation of the marker virus, and detection of the marker virus. The concentration system involves adsorption of virus to cellulose acetate filters in the presence of trivalent cations and low pH with subsequent desorption of the virus using volumes of high pH buffer. The detection of the virus is performed by a passive immune agglutination test utilizing specially prepared polystyrene particles. An engineering preliminary design was performed as a parallel effort to the laboratory development of the marker virus test system. Engineering schematics and drawings of a fully functional laboratory prototype capable of zero-G operation are presented. The instrument consists of reagent pump/metering system, reagent storage containers, a filter concentrator, an incubation/detector system, and an electronic readout and control system.

  3. DETECTION OR WARNING SYSTEM

    DOEpatents

    Tillman, J E

    1953-10-20

    This patent application describes a sensitive detection or protective system capable of giving an alarm or warning upon the entrance or intrusion of any body into a defined area or zone protected by a radiation field of suitable direction or extent.

  4. A concept for early cancer detection and therapy

    NASA Astrophysics Data System (ADS)

    Waynant, Ronald W.; Ilev, Ilko K.; Mitra, Kunal

    2003-06-01

    Early detection and treatment of breast cancer is least costly in terms of dollars, morbidity and mortality. With new early detection x-ray technology, tumors can be found, diagnosed and treated at a much smaller size than is currently possible. This paper proposes the development of a high resolution, high quality imaging system. It is a laser-driven x-ray system with time-gated detection that removes scattering noise in the image and produces resolution on the order of 10 μm. This higher resolution and higher image quality will enable the detection of one or two millimeter tumors hopefully detecting them before metastasis. We also propose that tumor detection should be followed by an immediate needle-directed, optical fiber biopsy to instantly determine if cancer is present and, if present, the tumor should immediately be given a lethal treatment of laser or x-radiation through the same needle using fiber optics or hollow waveguides. This technology will help prevent multiple interventions resulting in both the lowest overall cost and a more efficacious therapy. The approach can be stopped at the first negative (benign) indication and will help forestall repeated examination as well as reduce patient anxiety.

  5. Early Detection and Screening for Breast Cancer.

    PubMed

    Coleman, Cathy

    2017-05-01

    To review the history, current status, and future trends related to breast cancer screening. Peer-reviewed articles, web sites, and textbooks. Breast cancer remains a complex, heterogeneous disease. Serial screening with mammography is the most effective method to detect early stage disease and decrease mortality. Although politics and economics may inhibit organized mammography screening programs in many countries, the judicious use of proficient clinical and self-breast examination can also identify small tumors leading to reduced morbidity. Oncology nurses have exciting opportunities to lead, facilitate, and advocate for delivery of high-quality screening services targeting individuals and communities. A practical approach is needed to translate the complexities and controversies surrounding breast cancer screening into improved care outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Multisensor configurations for early sniper detection

    NASA Astrophysics Data System (ADS)

    Lindgren, D.; Bank, D.; Carlsson, L.; Dulski, R.; Duval, Y.; Fournier, G.; Grasser, R.; Habberstad, H.; Jacquelard, C.; Kastek, M.; Otterlei, R.; Piau, G.-P.; Pierre, F.; Renhorn, I.; Sjöqvist, L.; Steinvall, O.; Trzaskawka, P.

    2011-11-01

    This contribution reports some of the fusion results from the EDA SNIPOD project, where different multisensor configurations for sniper detection and localization have been studied. A project aim has been to cover the whole time line from sniper transport and establishment to shot. To do so, different optical sensors with and without laser illumination have been tested, as well as acoustic arrays and solid state projectile radar. A sensor fusion node collects detections and background statistics from all sensors and employs hypothesis testing and multisensor estimation programs to produce unified and reliable sniper alarms and accurate sniper localizations. Operator interfaces that connect to the fusion node should be able to support both sniper countermeasures and the guidance of personnel to safety. Although the integrated platform has not been actually built, sensors have been evaluated at common field trials with military ammunitions in the caliber range 5.56 to 12.7 mm, and at sniper distances up to 900 m. It is concluded that integrating complementary sensors for pre- and postshot sniper detection in a common system with automatic detection and fusion will give superior performance, compared to stand alone sensors. A practical system is most likely designed with a cost effective subset of available complementary sensors.

  7. APDS: Autonomous Pathogen Detection System

    SciT

    Langlois, R G; Brown, S; Burris, L

    An early warning system to counter bioterrorism, the Autonomous Pathogen Detection System (APDS) continuously monitors the environment for the presence of biological pathogens (e.g., anthrax) and once detected, it sounds an alarm much like a smoke detector warns of a fire. Long before September 11, 2001, this system was being developed to protect domestic venues and events including performing arts centers, mass transit systems, major sporting and entertainment events, and other high profile situations in which the public is at risk of becoming a target of bioterrorist attacks. Customizing off-the-shelf components and developing new components, a multidisciplinary team developed APDS,more » a stand-alone system for rapid, continuous monitoring of multiple airborne biological threat agents in the environment. The completely automated APDS samples the air, prepares fluid samples in-line, and performs two orthogonal tests: immunoassay and nucleic acid detection. When compared to competing technologies, APDS is unprecedented in terms of flexibility and system performance.« less

  8. Radiation detection system

    DOEpatents

    Nelson, Melvin A.; Davies, Terence J.; Morton, III, John R.

    1976-01-01

    A radiation detection system which utilizes the generation of Cerenkov light in and the transmission of that light longitudinally through fiber optic wave guides in order to transmit intelligence relating to the radiation to a remote location. The wave guides are aligned with respect to charged particle radiation so that the Cerenkov light, which is generated at an angle to the radiation, is accepted by the fiber for transmission therethrough. The Cerenkov radiation is detected, recorded, and analyzed at the other end of the fiber.

  9. Early hearing detection and intervention: 2010 CODEPEH recommendation.

    PubMed

    Trinidad-Ramos, Germán; de Aguilar, Valentín Alzina; Jaudenes-Casaubón, Carmen; Núñez-Batalla, Faustino; Sequí-Canet, José Miguel

    2010-01-01

    Newborn hearing screening is currently performed routinely in many regional health-care systems in Spain. Despite the remarkable expansion in newborn hearing screening since 2000, its feasibility and the benefits of early identification and intervention, many major challenges still remain. In this article, the Committee for the Early Detection of Hearing Loss (Comisión para la Detección Precoz de la Hipoacusia, CODEPEH) updates the recommendations that are considered important for the future development of early hearing detection and intervention (EDHI) systems in the following points: 1. Screening protocols: Separate protocols are recommended for NICU (Neonatal Intensive Care Units) and well-infant nurseries. 2. Diagnostic audiology evaluation. Professionals with skills and expertise in evaluating newborn and young infants should provide diagnosis, selection and fitting of amplification devices. 3. Medical evaluation. Risk factors for congenital and acquired hearing loss have been combined in a single list rather than grouped by time of onset. A stepwise diagnostic paradigm is diagnostically more efficient and cost-effective than a simultaneous testing approach. 4. Early intervention and surveillance. All individuals providing services to infants with hearing loss should have specialized training and expertise in the development of audition, speech and language. Regular surveillance should be performed on developmental milestones, auditory skills, parental concerns, and middle ear status. 5. Quality control. Data management as part of an integrated system is important to monitor and improve the quality of EDHI services. 2009 Elsevier España, S.L. All rights reserved.

  10. Early Training Estimation System

    DTIC Science & Technology

    1984-06-01

    Cybernetics and Society, 1980, pp. 1067-1974. J. David , J. Price, Successful communication in full scale engineering development statements of work. Air Force...Technical Memorandum 24-80, 1980, US Army Engineering Laboratory. S. Shrier , Algorithms for system design. Proceedings of the international conference on

  11. Structural and Functional Evaluations for the Early Detection of Glaucoma.

    PubMed

    Lucy, Katie A; Wollstein, Gadi

    2016-01-01

    The early detection of glaucoma is imperative in order to preserve functional vision. Structural and functional methods are utilized to detect and monitor glaucomatous damage and the vision loss it causes. The relationship between these detection measures is complex and differs between individuals, especially in early glaucoma. Using both measures together is advised in order to ensure the highest probability of glaucoma detection, and new testing methods are continuously developed with the goals of earlier disease detection and improvement of disease monitoring. The purpose of this review is to explore the relationship between structural and functional glaucoma detection and discuss important technological advances for early glaucoma detection.

  12. Structural and Functional Evaluations for the Early Detection of Glaucoma

    PubMed Central

    Lucy, Katie A.; Wollstein, Gadi

    2016-01-01

    The early detection of glaucoma is imperative in order to preserve functional vision. Structural and functional methods are utilized to detect and monitor glaucomatous damage and the vision loss it causes. The relationship between these detection measures is complex and differs between individuals, especially in early glaucoma. Using both measures together is advised in order to ensure the highest probability of glaucoma detection, and new testing methods are continuously developed with the goals of earlier disease detection and improvement of disease monitoring. The purpose of this review is to explore the relationship between structural and functional glaucoma detection and discuss important technological advances for early glaucoma detection. PMID:28603546

  13. Early Training Estimation System

    DTIC Science & Technology

    1980-08-01

    first year efforts in CTES development were Cecil Wakelin, Gavin Livingstone, Ray Walsh« Peter Weddle, David Herlihy, Laurel Brown, Drs. Paul Ronco...and Society, 1980, pp. 1067-1974. David , J., Price, J. Successful communication in full scale engineering development statements of work. Air Force...1980, U.S. Army Engineering Laboratory. Shrier , S. Algorithms for system design. Proceedings of the International Conference on Cybernetics and

  14. Life expectancy and the value of early detection.

    PubMed

    Howard, David H

    2005-09-01

    This paper presents a model of the benefits and costs of early detection of asymptomatic disease as they vary by age. The benefits of early detection tend toward zero as the risk of death from competing causes increases. Costs per detected case also decline with age, assuming that disease incidence rises with age, but are always strictly positive. On balance, there is always an age limit beyond which the costs associated with early detection outweigh the benefits. Application of the model to prostate cancer screening suggests that early detection above age 70 or so is not cost-effective.

  15. Automated detection of dark and bright lesions in retinal images for early detection of diabetic retinopathy.

    PubMed

    Akram, Usman M; Khan, Shoab A

    2012-10-01

    There is an ever-increasing interest in the development of automatic medical diagnosis systems due to the advancement in computing technology and also to improve the service by medical community. The knowledge about health and disease is required for reliable and accurate medical diagnosis. Diabetic Retinopathy (DR) is one of the most common causes of blindness and it can be prevented if detected and treated early. DR has different signs and the most distinctive are microaneurysm and haemorrhage which are dark lesions and hard exudates and cotton wool spots which are bright lesions. Location and structure of blood vessels and optic disk play important role in accurate detection and classification of dark and bright lesions for early detection of DR. In this article, we propose a computer aided system for the early detection of DR. The article presents algorithms for retinal image preprocessing, blood vessel enhancement and segmentation and optic disk localization and detection which eventually lead to detection of different DR lesions using proposed hybrid fuzzy classifier. The developed methods are tested on four different publicly available databases. The presented methods are compared with recently published methods and the results show that presented methods outperform all others.

  16. Water system virus detection

    NASA Technical Reports Server (NTRS)

    Fraser, A. S.; Wells, A. F.; Tenoso, H. J. (Inventor)

    1978-01-01

    The performance of a waste water reclamation system is monitored by introducing a non-pathogenic marker virus, bacteriophage F2, into the waste-water prior to treatment and, thereafter, testing the reclaimed water for the presence of the marker virus. A test sample is first concentrated by absorbing any marker virus onto a cellulose acetate filter in the presence of a trivalent cation at low pH and then flushing the filter with a limited quantity of a glycine buffer solution to desorb any marker virus present on the filter. Photo-optical detection of indirect passive immune agglutination by polystyrene beads indicates the performance of the water reclamation system in removing the marker virus. A closed system provides for concentrating any marker virus, initiating and monitoring the passive immune agglutination reaction, and then flushing the system to prepare for another sample.

  17. Ultrasonic Leak Detection System

    NASA Technical Reports Server (NTRS)

    Youngquist, Robert C. (Inventor); Moerk, J. Steven (Inventor)

    1998-01-01

    A system for detecting ultrasonic vibrations. such as those generated by a small leak in a pressurized container. vessel. pipe. or the like. comprises an ultrasonic transducer assembly and a processing circuit for converting transducer signals into an audio frequency range signal. The audio frequency range signal can be used to drive a pair of headphones worn by an operator. A diode rectifier based mixing circuit provides a simple, inexpensive way to mix the transducer signal with a square wave signal generated by an oscillator, and thereby generate the audio frequency signal. The sensitivity of the system is greatly increased through proper selection and matching of the system components. and the use of noise rejection filters and elements. In addition, a parabolic collecting horn is preferably employed which is mounted on the transducer assembly housing. The collecting horn increases sensitivity of the system by amplifying the received signals. and provides directionality which facilitates easier location of an ultrasonic vibration source.

  18. A Virtual Bioinformatics Knowledge Environment for Early Cancer Detection

    NASA Technical Reports Server (NTRS)

    Crichton, Daniel; Srivastava, Sudhir; Johnsey, Donald

    2003-01-01

    Discovery of disease biomarkers for cancer is a leading focus of early detection. The National Cancer Institute created a network of collaborating institutions focused on the discovery and validation of cancer biomarkers called the Early Detection Research Network (EDRN). Informatics plays a key role in enabling a virtual knowledge environment that provides scientists real time access to distributed data sets located at research institutions across the nation. The distributed and heterogeneous nature of the collaboration makes data sharing across institutions very difficult. EDRN has developed a comprehensive informatics effort focused on developing a national infrastructure enabling seamless access, sharing and discovery of science data resources across all EDRN sites. This paper will discuss the EDRN knowledge system architecture, its objectives and its accomplishments.

  19. Gas Flow Detection System

    NASA Technical Reports Server (NTRS)

    Moss, Thomas; Ihlefeld, Curtis; Slack, Barry

    2010-01-01

    This system provides a portable means to detect gas flow through a thin-walled tube without breaking into the tubing system. The flow detection system was specifically designed to detect flow through two parallel branches of a manifold with only one inlet and outlet, and is a means for verifying a space shuttle program requirement that saves time and reduces the risk of flight hardware damage compared to the current means of requirement verification. The prototype Purge Vent and Drain Window Cavity Conditioning System (PVD WCCS) Flow Detection System consists of a heater and a temperature-sensing thermistor attached to a piece of Velcro to be attached to each branch of a WCCS manifold for the duration of the requirement verification test. The heaters and thermistors are connected to a shielded cable and then to an electronics enclosure, which contains the power supplies, relays, and circuit board to provide power, signal conditioning, and control. The electronics enclosure is then connected to a commercial data acquisition box to provide analog to digital conversion as well as digital control. This data acquisition box is then connected to a commercial laptop running a custom application created using National Instruments LabVIEW. The operation of the PVD WCCS Flow Detection System consists of first attaching a heater/thermistor assembly to each of the two branches of one manifold while there is no flow through the manifold. Next, the software application running on the laptop is used to turn on the heaters and to monitor the manifold branch temperatures. When the system has reached thermal equilibrium, the software application s graphical user interface (GUI) will indicate that the branch temperatures are stable. The operator can then physically open the flow control valve to initiate the test flow of gaseous nitrogen (GN2) through the manifold. Next, the software user interface will be monitored for stable temperature indications when the system is again at

  20. Arc fault detection system

    DOEpatents

    Jha, K.N.

    1999-05-18

    An arc fault detection system for use on ungrounded or high-resistance-grounded power distribution systems is provided which can be retrofitted outside electrical switchboard circuits having limited space constraints. The system includes a differential current relay that senses a current differential between current flowing from secondary windings located in a current transformer coupled to a power supply side of a switchboard, and a total current induced in secondary windings coupled to a load side of the switchboard. When such a current differential is experienced, a current travels through a operating coil of the differential current relay, which in turn opens an upstream circuit breaker located between the switchboard and a power supply to remove the supply of power to the switchboard. 1 fig.

  1. Arc fault detection system

    DOEpatents

    Jha, Kamal N.

    1999-01-01

    An arc fault detection system for use on ungrounded or high-resistance-grounded power distribution systems is provided which can be retrofitted outside electrical switchboard circuits having limited space constraints. The system includes a differential current relay that senses a current differential between current flowing from secondary windings located in a current transformer coupled to a power supply side of a switchboard, and a total current induced in secondary windings coupled to a load side of the switchboard. When such a current differential is experienced, a current travels through a operating coil of the differential current relay, which in turn opens an upstream circuit breaker located between the switchboard and a power supply to remove the supply of power to the switchboard.

  2. Glycol leak detection system

    NASA Astrophysics Data System (ADS)

    Rabe, Paul; Browne, Keith; Brink, Janus; Coetzee, Christiaan J.

    2016-07-01

    MonoEthylene glycol coolant is used extensively on the Southern African Large Telescope to cool components inside the telescope chamber. To prevent coolant leaks from causing serious damage to electronics and optics, a Glycol Leak Detection System was designed to automatically shut off valves in affected areas. After two years of research and development the use of leaf wetness sensors proved to work best and is currently operational. These sensors are placed at various critical points within the instrument payload that would trigger the leak detector controller, which closes the valves, and alerts the building management system. In this paper we describe the research of an initial concept and the final accepted implementation and the test results thereof.

  3. Passive intrusion detection system

    NASA Technical Reports Server (NTRS)

    Laue, E. G. (Inventor)

    1980-01-01

    An intrusion detection system is described in which crystal oscillators are used to provide a frequency which varies as a function of fluctuations of a particular environmental property of the atmosphere, e.g., humidity, in the protected volume. The system is based on the discovery that the frequency of an oscillator whose crystal is humidity sensitive, varies at a frequency or rate which is within a known frequency band, due to the entry of an intruder into the protected volume. The variable frequency is converted into a voltage which is then filtered by a filtering arrangement which permits only voltage variations at frequencies within the known frequency band to activate an alarm, while inhibiting the alarm activation when the voltage frequency is below or above the known frequency band.

  4. Systematic review of surveillance systems and methods for early detection of exotic, new and re-emerging diseases in animal populations.

    PubMed

    Rodríguez-Prieto, V; Vicente-Rubiano, M; Sánchez-Matamoros, A; Rubio-Guerri, C; Melero, M; Martínez-López, B; Martínez-Avilés, M; Hoinville, L; Vergne, T; Comin, A; Schauer, B; Dórea, F; Pfeiffer, D U; Sánchez-Vizcaíno, J M

    2015-07-01

    In this globalized world, the spread of new, exotic and re-emerging diseases has become one of the most important threats to animal production and public health. This systematic review analyses conventional and novel early detection methods applied to surveillance. In all, 125 scientific documents were considered for this study. Exotic (n = 49) and re-emerging (n = 27) diseases constituted the most frequently represented health threats. In addition, the majority of studies were related to zoonoses (n = 66). The approaches found in the review could be divided in surveillance modalities, both active (n = 23) and passive (n = 5); and tools and methodologies that support surveillance activities (n = 57). Combinations of surveillance modalities and tools (n = 40) were also found. Risk-based approaches were very common (n = 60), especially in the papers describing tools and methodologies (n = 50). The main applications, benefits and limitations of each approach were extracted from the papers. This information will be very useful for informing the development of tools to facilitate the design of cost-effective surveillance strategies. Thus, the current literature review provides key information about the advantages, disadvantages, limitations and potential application of methodologies for the early detection of new, exotic and re-emerging diseases.

  5. Urine test could become early detection device.

    PubMed

    1999-03-01

    Researchers at the Clinical Reference Laboratory in Kansas have detected HIV antibodies in the urine of 24 low-risk people who tested negative for HIV in blood tests. These people are presumed to have been exposed to the virus, but it is not known yet if they actually carry the infection. It is possible for the virus and its antibodies to appear in the urogenital tract before spreading to the bloodstream. If this is correct, the urine test could become a way to screen high-risk individuals, who as a result may be able to initiate highly active antiretroviral therapy (HAART) before the infection becomes systemic. Study results will be presented at the American Association of Clinical Chemists meeting.

  6. Progress towards an AIS early detection monitoring network for the Great Lakes

    EPA Science Inventory

    As an invasion prone location, the lower St. Louis River system (SLR) has been a case study for ongoing research to develop the framework for a practical Great Lakes monitoring network for early detection of aquatic invasive species (AIS). Early detection, however, necessitates f...

  7. A decade of aquatic invasive species (AIS) early detection ...

    EPA Pesticide Factsheets

    As an invasion prone location, the St. Louis River Estuary (SLRE) has been a case study for ongoing research to develop the framework for a practical Great Lakes monitoring network for early detection of aquatic invasive species (AIS). Early detection, however, necessitates finding new invaders before they are common. Here we outline our research (2005 present) approach and findings, including strategies to increase detection efficiency by optimizing specimen collection and identification methods. Initial surveys were designed to over-sample to amass data as the basis for numerical experiments to investigate to the effort required for a given detection probability. Later surveys tested the outcome of implementing these strategies, examined the potential benefits of sampling larval fish instead of adults and explored the prospect of using advanced DNA based methods as an alternative to traditional taxonomy. To date we have identified several previously undetected invertebrate invaders, developed survey design and gear recommendations and have refined the search strategy for systems beyond the SLRE. In addition, because we’ve accumulated such a large body of data we now have the basis to show spatial-temporal trends for native and non-native species in the SLRE. not applicable

  8. Early indices of deviance detection in humans and animal models.

    PubMed

    Grimm, Sabine; Escera, Carles; Nelken, Israel

    2016-04-01

    Detecting unexpected stimuli in the environment is a critical function of the auditory system. Responses to unexpected "deviant" sounds are enhanced compared to responses to expected stimuli. At the human scalp, deviance detection is reflected in the mismatch negativity (MMN) and in an enhancement of the middle-latency response (MLR). Single neurons often respond more strongly to a stimulus when rare than when common, a phenomenon termed stimulus-specific adaptation (SSA). Here we compare stimulus-specific adaptation with scalp-recorded deviance-related responses. We conclude that early markers of deviance detection in the time range of the MLR could be a direct correlate of cortical SSA. Both occur at an early level of cortical activation, both are robust findings with low-probability stimuli, and both show properties of genuine deviance detection. Their causal relation with the later scalp-recorded MMN is a key question in this field. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Concrete bridge deck early problem detection and mitigation using robotics

    NASA Astrophysics Data System (ADS)

    Gucunski, Nenad; Yi, Jingang; Basily, Basily; Duong, Trung; Kim, Jinyoung; Balaguru, Perumalsamy; Parvardeh, Hooman; Maher, Ali; Najm, Husam

    2015-04-01

    More economical management of bridges can be achieved through early problem detection and mitigation. The paper describes development and implementation of two fully automated (robotic) systems for nondestructive evaluation (NDE) and minimally invasive rehabilitation of concrete bridge decks. The NDE system named RABIT was developed with the support from Federal Highway Administration (FHWA). It implements multiple NDE technologies, namely: electrical resistivity (ER), impact echo (IE), ground-penetrating radar (GPR), and ultrasonic surface waves (USW). In addition, the system utilizes advanced vision to substitute traditional visual inspection. The RABIT system collects data at significantly higher speeds than it is done using traditional NDE equipment. The associated platform for the enhanced interpretation of condition assessment in concrete bridge decks utilizes data integration, fusion, and deterioration and defect visualization. The interpretation and visualization platform specifically addresses data integration and fusion from the four NDE technologies. The data visualization platform facilitates an intuitive presentation of the main deterioration due to: corrosion, delamination, and concrete degradation, by integrating NDE survey results and high resolution deck surface imaging. The rehabilitation robotic system was developed with the support from National Institute of Standards and Technology-Technology Innovation Program (NIST-TIP). The system utilizes advanced robotics and novel materials to repair problems in concrete decks, primarily early stage delamination and internal cracking, using a minimally invasive approach. Since both systems use global positioning systems for navigation, some of the current efforts concentrate on their coordination for the most effective joint evaluation and rehabilitation.

  10. EDIM-TKTL1/Apo10 Blood Test: An Innate Immune System Based Liquid Biopsy for the Early Detection, Characterization and Targeted Treatment of Cancer.

    PubMed

    Coy, Johannes F

    2017-04-20

    Epitope detection in monocytes (EDIM) represents a liquid biopsy exploiting the innate immune system. Activated monocytes (macrophages) phagocytose unwanted cells/cell fragments from the whole body including solid tissues. As they return to the blood, macrophages can be used for a non-invasive detection of biomarkers, thereby providing high sensitivity and specificity, because the intracellular presence of biomarkers is due to an innate immune response. Flow cytometry analysis of blood enables the detection of macrophages and phagocytosed intracellular biomarkers. In order to establish a pan-cancer test, biomarkers for two fundamental biophysical mechanisms have been exploited. The DNaseX/Apo10 protein epitope is a characteristic of tumor cells with abnormal apoptosis and proliferation. Transketolase-like 1 (TKTL1) is a marker for an anaerobic glucose metabolism (Warburg effect), which is concomitant with invasive growth/metastasis and resistant to radical and apoptosis inducing therapies. The detection of Apo10 and TKTL1 in blood macrophages allowed a sensitive (95.8%) and specific (97.3%) detection of prostate, breast and oral squamous cell carcinomas. Since TKTL1 represents a drugable target, the EDIM based detection of TKTL1 enables a targeted cancer therapy using the vitamin derivatives oxythiamine or benfo-oxythiamine.

  11. NORSAR detection processing system

    NASA Astrophysics Data System (ADS)

    Loughran, L. B.

    1987-05-01

    This Semiannual Technical Summary describes the operation, maintenance and research activities at the Norwegian Seismic Array (NORSAR). Investigations into further potential improvements in the NORSAR array processing system have continued. A new Detection Processor (DP) program has developed and tested in an off-line mode. This program is flexible enough to conduct both NORSAR and NORESS detection processing as is done today, besides incorporating improved algorithms. A wide-band slowness estimation technique has been investigated by processing data from several events from the same location. Ten quarry blasts at a dam construction site in western Russia and sixteen Semipalatinsk nuclear explosions were selected. The major conclusion from this study is that employing a wider frequency band clearly tends to increase the stability of the slowness estimates, provided the signal-to-noise ratio is adequate over the band of interest. The stability was found, particularly for Pn, to be remarkably good for the western Norway quarry blasts when using a fixed frequency band for each phase for all ten events.

  12. Early detection of non-native fishes using fish larvae

    EPA Science Inventory

    Our objective was to evaluate the use of fish larvae for early detection of non-native fishes, comparing traditional and molecular taxonomy approaches to investigate potential efficiencies. Fish larvae present an interesting opportunity for non-native fish early detection. First,...

  13. Dynamic linear models using the Kalman filter for early detection and early warning of malaria outbreaks

    NASA Astrophysics Data System (ADS)

    Merkord, C. L.; Liu, Y.; DeVos, M.; Wimberly, M. C.

    2015-12-01

    Malaria early detection and early warning systems are important tools for public health decision makers in regions where malaria transmission is seasonal and varies from year to year with fluctuations in rainfall and temperature. Here we present a new data-driven dynamic linear model based on the Kalman filter with time-varying coefficients that are used to identify malaria outbreaks as they occur (early detection) and predict the location and timing of future outbreaks (early warning). We fit linear models of malaria incidence with trend and Fourier form seasonal components using three years of weekly malaria case data from 30 districts in the Amhara Region of Ethiopia. We identified past outbreaks by comparing the modeled prediction envelopes with observed case data. Preliminary results demonstrated the potential for improved accuracy and timeliness over commonly-used methods in which thresholds are based on simpler summary statistics of historical data. Other benefits of the dynamic linear modeling approach include robustness to missing data and the ability to fit models with relatively few years of training data. To predict future outbreaks, we started with the early detection model for each district and added a regression component based on satellite-derived environmental predictor variables including precipitation data from the Tropical Rainfall Measuring Mission (TRMM) and land surface temperature (LST) and spectral indices from the Moderate Resolution Imaging Spectroradiometer (MODIS). We included lagged environmental predictors in the regression component of the model, with lags chosen based on cross-correlation of the one-step-ahead forecast errors from the first model. Our results suggest that predictions of future malaria outbreaks can be improved by incorporating lagged environmental predictors.

  14. Early Oscillation Detection for DC/DC Converter Fault Diagnosis

    NASA Technical Reports Server (NTRS)

    Wang, Bright L.

    2011-01-01

    The electrical power system of a spacecraft plays a very critical role for space mission success. Such a modern power system may contain numerous hybrid DC/DC converters both inside the power system electronics (PSE) units and onboard most of the flight electronics modules. One of the faulty conditions for DC/DC converter that poses serious threats to mission safety is the random occurrence of oscillation related to inherent instability characteristics of the DC/DC converters and design deficiency of the power systems. To ensure the highest reliability of the power system, oscillations in any form shall be promptly detected during part level testing, system integration tests, flight health monitoring, and on-board fault diagnosis. The popular gain/phase margin analysis method is capable of predicting stability levels of DC/DC converters, but it is limited only to verification of designs and to part-level testing on some of the models. This method has to inject noise signals into the control loop circuitry as required, thus, interrupts the DC/DC converter's normal operation and increases risks of degrading and damaging the flight unit. A novel technique to detect oscillations at early stage for flight hybrid DC/DC converters was developed.

  15. Incipient fire detection system

    DOEpatents

    Brooks, Jr., William K.

    1999-01-01

    A method and apparatus for an incipient fire detection system that receives gaseous samples and measures the light absorption spectrum of the mixture of gases evolving from heated combustibles includes a detector for receiving gaseous samples and subjecting the samples to spectroscopy and determining wavelengths of absorption of the gaseous samples. The wavelengths of absorption of the gaseous samples are compared to predetermined absorption wavelengths. A warning signal is generated whenever the wavelengths of absorption of the gaseous samples correspond to the predetermined absorption wavelengths. The method includes receiving gaseous samples, subjecting the samples to light spectroscopy, determining wavelengths of absorption of the gaseous samples, comparing the wavelengths of absorption of the gaseous samples to predetermined absorption wavelengths and generating a warning signal whenever the wavelengths of absorption of the gaseous samples correspond to the predetermined absorption wavelengths. In an alternate embodiment, the apparatus includes a series of channels fluidically connected to a plurality of remote locations. A pump is connected to the channels for drawing gaseous samples into the channels. A detector is connected to the channels for receiving the drawn gaseous samples and subjecting the samples to spectroscopy. The wavelengths of absorption are determined and compared to predetermined absorption wavelengths is provided. A warning signal is generated whenever the wavelengths correspond.

  16. Early warning system for aftershocks

    Bakun, W.H.; Fischer, F.G.; Jensen, E.G.; VanSchaack, J.

    1994-01-01

    A prototype early warning system to provide San Francisco and Oakland, California a few tens-of-seconds warning of incoming strong ground shaking from already-occurred M ≧ 3.7 aftershocks of the magnitude 7.1 17 October 1989 Loma Prieta earthquake was operational on 28 October 1989. The prototype system consisted of four components: ground motion sensors in the epicentral area, a central receiver, a radio repeater, and radio receivers. One of the radio receivers was deployed at the California Department of Transportation (CALTRANS) headquarters at the damaged Cypress Street section of the I-880 freeway in Oakland, California on 28 October 1989 and provided about 20 sec of warning before shaking from the M 4.5 Loma Prieta aftershock that occurred on 2 November 1989 at 0550 UTC. In its first 6 months of operation, the system generated triggers for all 12 M > 3.7 aftershocks for which trigger documentation is preserved, did not trigger on any M ≦ 3.6 aftershocks, and produced one false trigger as a result of a now-corrected single point of failure design flaw. Because the prototype system demonstrated that potentially useful warnings of strong shaking from aftershocks are feasible, the USGS has completed a portable early warning system for aftershocks that can be deployed anywhere.

  17. Estimation for aerial detection effectiveness with cooperation efficiency factors of early-warning aircraft in early-warning detection SoS under BSC framework

    NASA Astrophysics Data System (ADS)

    Zhu, Feng; Hu, Xiaofeng; He, Xiaoyuan; Guo, Rui; Li, Kaiming; Yang, Lu

    2017-11-01

    In the military field, the performance evaluation of early-warning aircraft deployment or construction is always an important problem needing to be explored. As an effective approach of enterprise management and performance evaluation, Balanced Score Card (BSC) attracts more and more attentions and is studied more and more widely all over the world. It can also bring feasible ideas and technical approaches for studying the issue of the performance evaluation of the deployment or construction of early-warning aircraft which is the important component in early-warning detection system of systems (SoS). Therefore, the deep explored researches are carried out based on the previously research works. On the basis of the characteristics of space exploration and aerial detection effectiveness of early-warning detection SoS and the cardinal principle of BSC are analyzed simply, and the performance evaluation framework of the deployment or construction of early-warning aircraft is given, under this framework, aimed at the evaluation issue of aerial detection effectiveness of early-warning detection SoS with the cooperation efficiency factors of the early-warning aircraft and other land based radars, the evaluation indexes are further designed and the relative evaluation model is further established, especially the evaluation radar chart being also drawn to obtain the evaluation results from a direct sight angle. Finally, some practical computer simulations are launched to prove the validity and feasibility of the research thinking and technologic approaches which are proposed in the paper.

  18. Nanomedicine for Early Disease Detection and Treatment

    DTIC Science & Technology

    2013-09-01

    AD_________________ Award Number: W81XWH-11-1-0442 TITLE: Nanomedicine for early disease ...been developed to report and cure diseases . ESNM is prepared with multiple layers of polyelectrolytes, sequentially assembled on an inert gold...molecular characteristics of the patient and his/her specific diseased tissues with the treatment. In order to maximize therapeutic effects and

  19. Early detection of protozoan grazers in algal biofuel cultures.

    PubMed

    Day, John G; Thomas, Naomi J; Achilles-Day, Undine E M; Leakey, Raymond J G

    2012-06-01

    Future micro-algal biofuels will most likely be derived from open-pond production systems. These are by definition open to "invasion" by grazers, which could devastate micro-algal mass-cultures. There is an urgent requirement for methodologies capable of early detection and control of grazers in dense algal cultures. In this study a model system employing the marine alga Nannochloropsis oculata was challenged by grazers including ciliates, amoebae and a heterotrophic dinoflagellate. A FlowCAM flow-cytometer was used to detect all grazers investigated (size range <20->80 μm in length) in the presence of algae. Detection limits were <10 cells ml(-1) for both "large" and "small" model grazers, Euplotes vannus (80 × 45 μm) and an unidentified holotrichous ciliate (~18 × 8 μm) respectively. Furthermore, the system can distinguish the presence of ciliates in N. oculata cultures with biotechnologically relevant cell densities; i.e. >1.4 × 10(8) cells ml(-1) (>0.5 g l(-1) dry wt.). Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Early bronchiectasis in cystic fibrosis detected by surveillance CT.

    PubMed

    Pillarisetti, Naveen; Linnane, Barry; Ranganathan, Sarath

    2010-08-01

    There is emerging evidence that cystic fibrosis lung disease begins early in infancy. Newborn screening allows early detection and surveillance of pulmonary disease and the possibility of early intervention in this life-shortening condition. We report two children with cystic fibrosis who underwent a comprehensive assessment from diagnosis that included measurement of lung function, limited-slice high-resolution CT and BAL performed annually. Early aggressive surveillance enabled significant lung disease and bronchiectasis to be detected during the first few years of life and led to a change in management, highlighting a clinical role for CT scanning during the preschool years in children with cystic fibrosis.

  1. FluBreaks: early epidemic detection from Google flu trends.

    PubMed

    Pervaiz, Fahad; Pervaiz, Mansoor; Abdur Rehman, Nabeel; Saif, Umar

    2012-10-04

    The Google Flu Trends service was launched in 2008 to track changes in the volume of online search queries related to flu-like symptoms. Over the last few years, the trend data produced by this service has shown a consistent relationship with the actual number of flu reports collected by the US Centers for Disease Control and Prevention (CDC), often identifying increases in flu cases weeks in advance of CDC records. However, contrary to popular belief, Google Flu Trends is not an early epidemic detection system. Instead, it is designed as a baseline indicator of the trend, or changes, in the number of disease cases. To evaluate whether these trends can be used as a basis for an early warning system for epidemics. We present the first detailed algorithmic analysis of how Google Flu Trends can be used as a basis for building a fully automated system for early warning of epidemics in advance of methods used by the CDC. Based on our work, we present a novel early epidemic detection system, called FluBreaks (dritte.org/flubreaks), based on Google Flu Trends data. We compared the accuracy and practicality of three types of algorithms: normal distribution algorithms, Poisson distribution algorithms, and negative binomial distribution algorithms. We explored the relative merits of these methods, and related our findings to changes in Internet penetration and population size for the regions in Google Flu Trends providing data. Across our performance metrics of percentage true-positives (RTP), percentage false-positives (RFP), percentage overlap (OT), and percentage early alarms (EA), Poisson- and negative binomial-based algorithms performed better in all except RFP. Poisson-based algorithms had average values of 99%, 28%, 71%, and 76% for RTP, RFP, OT, and EA, respectively, whereas negative binomial-based algorithms had average values of 97.8%, 17.8%, 60%, and 55% for RTP, RFP, OT, and EA, respectively. Moreover, the EA was also affected by the region's population size

  2. Intrusion detection: systems and models

    NASA Technical Reports Server (NTRS)

    Sherif, J. S.; Dearmond, T. G.

    2002-01-01

    This paper puts forward a review of state of the art and state of the applicability of intrusion detection systems, and models. The paper also presents a classfication of literature pertaining to intrusion detection.

  3. Synthesis of visibility detection systems.

    DOT National Transportation Integrated Search

    2012-10-01

    Visibility is a critical component to the task of driving on all types of roads. The visibility detection and warning systems provide real-time, automated detection as well as appropriate responses to counteract reduced visibility conditions due to f...

  4. Early detection of Alzheimer disease: methods, markers, and misgivings.

    PubMed

    Green, R C; Clarke, V C; Thompson, N J; Woodard, J L; Letz, R

    1997-01-01

    There is at present no reliable predictive test for most forms of Alzheimer disease (AD). Although some information about future risk for disease is available in theory through ApoE genotyping, it is of limited accuracy and utility. Once neuroprotective treatments are available for AD, reliable early detection will become a key component of the treatment strategy. We recently conducted a pilot survey eliciting attitudes and beliefs toward an unspecified and hypothetical predictive test for AD. The survey was completed by a convenience sample of 176 individuals, aged 22-77, which was 75% female, 30% African-American, and of which 33% had a family member with AD. The survey revealed that 69% of this sample would elect to obtain predictive testing for AD if the test were 100% accurate. Individuals were more likely to desire predictive testing if they had an a priori belief that they would develop AD (p = 0.0001), had a lower educational level (p = 0.003), were worried that they would develop AD (p = 0.02), had a self-defined history of depression (p = 0.04), and had a family member with AD (p = 0.04). However, the desire for predictive testing was not significantly associated with age, gender, ethnicity, or income. The desire to obtain predictive testing for AD decreased as the assumed accuracy of the hypothetical test decreased. A better short-term strategy for early detection of AD may be computer-based neuropsychological screening of at-risk (older aged) individuals to identify very early cognitive impairment. Individuals identified in this manner could be referred for diagnostic evaluation and early cases of AD could be identified and treated. A new self-administered, touch-screen, computer-based, neuropsychological screening instrument called Neurobehavioral Evaluation System-3 is described, which may facilitate this type of screening.

  5. Early detection of health and welfare compromises through automated detection of behavioural changes in pigs.

    PubMed

    Matthews, Stephen G; Miller, Amy L; Clapp, James; Plötz, Thomas; Kyriazakis, Ilias

    2016-11-01

    Early detection of health and welfare compromises in commercial piggeries is essential for timely intervention to enhance treatment success, reduce impact on welfare, and promote sustainable pig production. Behavioural changes that precede or accompany subclinical and clinical signs may have diagnostic value. Often referred to as sickness behaviour, this encompasses changes in feeding, drinking, and elimination behaviours, social behaviours, and locomotion and posture. Such subtle changes in behaviour are not easy to quantify and require lengthy observation input by staff, which is impractical on a commercial scale. Automated early-warning systems may provide an alternative by objectively measuring behaviour with sensors to automatically monitor and detect behavioural changes. This paper aims to: (1) review the quantifiable changes in behaviours with potential diagnostic value; (2) subsequently identify available sensors for measuring behaviours; and (3) describe the progress towards automating monitoring and detection, which may allow such behavioural changes to be captured, measured, and interpreted and thus lead to automation in commercial, housed piggeries. Multiple sensor modalities are available for automatic measurement and monitoring of behaviour, which require humans to actively identify behavioural changes. This has been demonstrated for the detection of small deviations in diurnal drinking, deviations in feeding behaviour, monitoring coughs and vocalisation, and monitoring thermal comfort, but not social behaviour. However, current progress is in the early stages of developing fully automated detection systems that do not require humans to identify behavioural changes; e.g., through automated alerts sent to mobile phones. Challenges for achieving automation are multifaceted and trade-offs are considered between health, welfare, and costs, between analysis of individuals and groups, and between generic and compromise-specific behaviours. Copyright © 2016

  6. Early detection of sporadic pancreatic cancer: summative review.

    PubMed

    Chari, Suresh T; Kelly, Kimberly; Hollingsworth, Michael A; Thayer, Sarah P; Ahlquist, David A; Andersen, Dana K; Batra, Surinder K; Brentnall, Teresa A; Canto, Marcia; Cleeter, Deborah F; Firpo, Matthew A; Gambhir, Sanjiv Sam; Go, Vay Liang W; Hines, O Joe; Kenner, Barbara J; Klimstra, David S; Lerch, Markus M; Levy, Michael J; Maitra, Anirban; Mulvihill, Sean J; Petersen, Gloria M; Rhim, Andrew D; Simeone, Diane M; Srivastava, Sudhir; Tanaka, Masao; Vinik, Aaron I; Wong, David

    2015-07-01

    Pancreatic cancer (PC) is estimated to become the second leading cause of cancer death in the United States by 2020. Early detection is the key to improving survival in PC. Addressing this urgent need, the Kenner Family Research Fund conducted the inaugural Early Detection of Sporadic Pancreatic Cancer Summit Conference in 2014 in conjunction with the 45th Anniversary Meeting of the American Pancreatic Association and Japan Pancreas Society. This seminal convening of international representatives from science, practice, and clinical research was designed to facilitate challenging interdisciplinary conversations to generate innovative ideas leading to the creation of a defined collaborative strategic pathway for the future of the field. An in-depth summary of current efforts in the field, analysis of gaps in specific areas of expertise, and challenges that exist in early detection is presented within distinct areas of inquiry: Case for Early Detection: Definitions, Detection, Survival, and Challenges; Biomarkers for Early Detection; Imaging; and Collaborative Studies. In addition, an overview of efforts in familial PC is presented in an addendum to this article. It is clear from the summit deliberations that only strategically designed collaboration among investigators, institutions, and funders will lead to significant progress in early detection of sporadic PC.

  7. An Early Warning System Based on Syndromic Surveillance to Detect Potential Health Emergencies among Migrants: Results of a Two-Year Experience in Italy

    PubMed Central

    Napoli, Christian; Riccardo, Flavia; Declich, Silvia; Dente, Maria Grazia; Pompa, Maria Grazia; Rizzo, Caterina; Rota, Maria Cristina; Bella, Antonino

    2014-01-01

    Profound geopolitical changes have impacted the southern and eastern Mediterranean since 2010 and defined a context of instability that is still affecting several countries today. Insecurity combined with the reduction of border controls has led to major population movements in the region and to migration surges from affected countries to southern Europe, especially to Italy. To respond to the humanitarian emergency triggered by this migration surge, Italy implemented a syndromic surveillance system in order to rapidly detect potential public health emergencies in immigrant reception centres. This system was discontinued after two years. This paper presents the results of this experience detailing its strengths and weaknesses in order to document the applicability and usefulness of syndromic surveillance in this specific context. PMID:25140999

  8. [Development of a diagnostic test system for early non-invasive detection of prostate cancer based on PCA3 mRNA levels in urine sediment using quantitative reverse tanscription polymerase chain reaction (qRT-PCR)].

    PubMed

    Pavlov, K A; Shkoporov, A N; Khokhlova, E V; Korchagina, A A; Sidorenkov, A V; Grigor'ev, M É; Pushkar', D Iu; Chekhonin, V P

    2013-01-01

    The wide introduction of prostatic specific antigen (PSA) determination into clinical practice has resulted in a larger number of prostate biopsies, while the lower age threshold for PSA has led to a larger number of unnecessary prostate biopsies. Hence, there is a need for new biomarkers that can detect prostate cancer. PCA3 is a noncoding messenger ribonucleic acid (mRNA) that is expressed exclusively in prostate cells. The aim of the study has been to develop a diagnostic test system for early non-invasive detection of prostate cancer based on PCA3 mRNA levels in urine sediment using quantitative reverse transcription polymerase chain reaction (qRT-PCR). As part of the study, a laboratory diagnostic test system prototype has been designed, an application methodology has been developed and specificity and sensitivity data of the method has been assessed. The diagnostic system has demonstrated its ability to detect significantly elevated levels of PCA 3/KLK 3 in samples from prostate cancer (PCa) patients compared with those from healthy men. The findings have shown relatively high diagnostic sensitivity, specificity and negative-predictive values for an early non-invasive screening of prostate cancer

  9. Innovative design for early detection of invasive species

    EPA Science Inventory

    Non-native aquatic species impose significant ecological impacts and rising financial costs in marine and freshwater ecosystems worldwide. Early detection of invasive species, as they enter a vulnerable ecosystem, is critical to successful containment and eradication. ORD, at t...

  10. [Early detection of autism in children. Review of literature].

    PubMed

    Pisula, E

    1997-01-01

    The difficulties with early detection of autistic disorder in children are discussed. DSM-IV diagnostic criteria are presented. Usefulness of clinical interview and clinical experiment in diagnosing autistic disorder are analyzed.

  11. Vessel and oil spill early detection using COSMO satellite imagery

    NASA Astrophysics Data System (ADS)

    Revollo, Natalia V.; Delrieux, Claudio A.

    2017-10-01

    Oil spillage is one of the most common sources of environmental damage in places where coastal wild life is found in natural reservoirs. This is especially the case in the Patagonian coast, with a littoral more than 5000 km long and a surface above a million and half square km. In addition, furtive fishery activities in Argentine waters are depleting the food supplies of several species, altering the ecological equilibrium. For this reason, early oil spills and vessel detection is an imperative surveillance task for environmental and governmental authorities. However, given the huge geographical extension, human assisted monitoring is unfeasible, and therefore real time remote sensing technologies are the only operative and economically feasible solution. In this work we describe the theoretical foundations and implementation details of a system specifically designed to take advantage of the SAR imagery delivered by two satellite constellations (the SAOCOM mission, developed by the Argentine Space Agency, and the COSMO mission, developed by the Italian Space Agency), to provide real-time detection of vessels and oil spills. The core of the system is based on pattern recognition over a statistical characterization of the texture patterns arising in the positive and negative conditions (i.e., vessel, oil, or plain sea surfaces). Training patterns were collected from a large number of previously reported contacts tagged by experts in the National Commission on Space Activities (CONAE). The resulting system performs well above the sensitivity and specificity of other avalilable systems.

  12. Raman spectroscopy and Raman imaging for early detection of cancer

    NASA Astrophysics Data System (ADS)

    Joshi, Narahari V.; Ortega, Angel; Estrela, Jose Maria

    2004-06-01

    Raman spectroscopy is a powerful technique as it provides fundamental information about vibrational modes of a system. Eigenvalues of these modes are very sensitive to the strength of the chemical bonds and perturbations caused by the environment, particularly charge distribution and alterations in the dipole strength of the system. All these parameters are profoundly modified during the tumor formation process nad hence Raman technique could be a unique and also a direct approach for evaluating tumor genesis at early stages. for this pupose the present investigation was carried out. We used cultured wild type and c-ras transformed NIH 3T3 fibroblast. The samples were treated with methyl alcohol solution ina conventional manner and then Raman spectra nad images were obtained by a specially developed confocal Raman microscope. The present results reveal differences between both cell types in the spectral details as well as in the morphology. Raman images are able to detect the exact site where cancer-related changes have taken place. These results clearly indicate the superiority of the present technique over conventional methods such as images obtained by X-rays or Nuclear Magnetic Resonance (NMR). Moreover, unlike other approaches, Raman images detect alterations at the submicron level rather than in the centimeter or millimeter range. Being an optical method it can be applied in vivo as a non-invasive technique potentially useful to early detection of cancer (particularly easy accessible cancers such as those of the skin and the digestive tract). The obtained resulsts suggest the great potential of Raman imaging in premature clinical diagnostic approaches.

  13. A Cell-Based Approach to Early Pancreatic Cancer Detection

    DTIC Science & Technology

    2016-10-01

    Award Number: W81XWH-15-1-0457 TITLE: A Cell -Based Approach to Early Pancreatic Cancer Detection PRINCIPAL INVESTIGATOR: Dr. Ben Stanger...SUBTITLE 5a. CONTRACT NUMBER A Cell -Based Approach to Early Pancreatic Cancer Detection 5b. GRANT NUMBER W81XWH-15-1-0457 5c. PROGRAM ELEMENT NUMBER 6...tumor cells from mouse blood by depleting the sample of white blood cells (WBCs). Furthermore, the RNA profile of these cells can be assessed by

  14. THE VERY EARLY LIGHT CURVE OF SN 2015F IN NGC 2442: A POSSIBLE DETECTION OF SHOCK-HEATED COOLING EMISSION AND CONSTRAINTS ON SN Ia PROGENITOR SYSTEM

    SciT

    Im, Myungshin; Choi, Changsu; Kim, Jae-Woo

    2015-11-15

    The main progenitor candidates of Type Ia supernovae (SNe Ia) are white dwarfs in binary systems where the companion star is another white dwarf (double degenerate (DD) system) or a less-evolved, non-degenerate star with R{sub *} ≳ 0.1 R{sub ⊙} (single degenerate system). However, no direct observational evidence exists to tell us which progenitor system is more common. Recent studies suggest that the light curve of a supernova shortly after its explosion can be used to set a limit on the progenitor size, R{sub *}. Here, we report high-cadence monitoring observations of SN 2015F, a normal SN Ia in themore » galaxy NGC 2442, starting about 84 days before the first light time. Using our daily cadence data, we capture the emergence of the radioactively powered light curve; more importantly, with >97.4% confidence, we detect possible dim precursor emission that appears roughly 1.5 days before the rise of the radioactively powered emission. The signal is consistent with theoretical expectations for a progenitor system involving a companion star with R{sub *} ≃ 0.1–1 R{sub ⊙} or a prompt explosion of a DD system, but is inconsistent with the typically invoked size of a white dwarf progenitor of R{sub *} ∼ 0.01 R{sub ⊙}. Upper limits on the precursor emission also constrain the progenitor size to be R{sub *} ≲ 0.1 R{sub ⊙} with a companion star size of R{sub *} ≲ 1.0 R{sub ⊙}, excluding a very large companion star in the progenitor system. Additionally, we find that the distance to SN 2015F is 23.9 ± 0.4 Mpc.« less

  15. Radiation detection and wireless networked early warning

    NASA Astrophysics Data System (ADS)

    Burns, David A.; Litz, Marc S.; Carroll, James J.; Katsis, Dimosthenis

    2012-06-01

    We have designed a compact, wireless, GPS-enabled array of inexpensive radiation sensors based on scintillation counting. Each sensor has a scintillator, photomultiplier tube, and pulse-counting circuit that includes a comparator, digital potentiometer and microcontroller. This design provides a high level of sensitivity and reliability. A 0.2 m2 PV panel powers each sensor providing a maintenance-free 24/7 energy source. The sensor can be mounted within a roadway light-post and monitor radiological activity along transport routes. Each sensor wirelessly transmits real-time data (as counts per second) up to 2 miles with a XBee radio module, and the data is received by a XBee receive-module on a computer. Data collection software logs the information from all sensors and provides real-time identification of radiation events. Measurements performed to-date demonstrate the ability of a sensor to detect a 20 μCi source at 3.5 meters when packaged with a PVT (plastic) scintillator, and 7 meters for a sensor with a CsI crystal (more expensive but ~5 times more sensitive). It is calculated that the sensor-architecture can detect sources moving as fast as 130 km/h based on the current data rate and statistical bounds of 3-sigma threshold detection. The sensor array is suitable for identifying and tracking a radiation threat from a dirty bomb along roadways.

  16. Antigen detection systems

    Infectious agents or their constituent parts (antigens or nucleic acids) can be detected in fresh, frozen, or fixed tissues or other specimens, using a variety of direct or indirect assays. The assays can be modified to yield the greatest sensitivity and specificity but in most cases a particular m...

  17. Early detection of dental caries using photoacoustics

    NASA Astrophysics Data System (ADS)

    Kim, K.; Witte, R.; Koh, I.; Ashkenazi, S.; O'Donnell, M.

    2006-02-01

    For decades, visual, tactile and radiographic examinations have been the standard for diagnosing caries. Nonetheless, the extent of variation in the diagnosis of dental caries is substantial among dental practitioners using these traditional techniques. Therefore, a more reliable standard for detecting incipient caries would be desirable. Using photoacoustics, near-infrared (NIR) optical contrast between sound and carious dental tissues can be relatively easily and accurately detected at ultrasound resolution. In this paper, a pulsed laser (Nd:YAG, Quanta-Ray) was used to probe extracted human molars at different disease stages determined from periapical radiographs. Both fundamental (1064nm) and first harmonic (532nm) pulses (15ns pulse length, 100mJ at fundamental and 9mJ at first harmonic , 10Hz pulse repetition rate) were used to illuminate the occlusal surface of tooth samples placed in a water tank. The photoacoustic signal was recorded with an unfocused wideband single-element piezoelectric transducer (centered at 12 MHz, bandwidth 15 MHz) positioned at small angle (less than 30 degrees) to the laser beam close to the occlusal surface. At the fundamental wavelength, total photoacoustic energy increases from normal to incipient stage disease by as much as a factor of 10. Differences between photoacoustic energy at the fundamental and first harmonic wavelength further indicate spectral absorption changes of the underlying structure with disease progression. Using a focused laser beam, an extracted molar with suspected incipient caries was scanned along the occulusal surface to help localize the caries inside enamel and dentin. The significantly increasing photoacoustic signal at a specific scan line both at fundamental and first harmonic indicates the local development of the incipient caries. The photoacoustic results compare well with visual inspection after layer by layer dissection. Preliminary results demonstrate the feasibility of detecting incipient

  18. Intrusion Detection in Database Systems

    NASA Astrophysics Data System (ADS)

    Javidi, Mohammad M.; Sohrabi, Mina; Rafsanjani, Marjan Kuchaki

    Data represent today a valuable asset for organizations and companies and must be protected. Ensuring the security and privacy of data assets is a crucial and very difficult problem in our modern networked world. Despite the necessity of protecting information stored in database systems (DBS), existing security models are insufficient to prevent misuse, especially insider abuse by legitimate users. One mechanism to safeguard the information in these databases is to use an intrusion detection system (IDS). The purpose of Intrusion detection in database systems is to detect transactions that access data without permission. In this paper several database Intrusion detection approaches are evaluated.

  19. Protein detection system

    DOEpatents

    Fruetel, Julie A [Livermore, CA; Fiechtner, Gregory J [Bethesda, MD; Kliner, Dahv A. V. [San Ramon, CA; McIlroy, Andrew [Livermore, CA

    2009-05-05

    The present embodiment describes a miniature, microfluidic, absorption-based sensor to detect proteins at sensitivities comparable to LIF but without the need for tagging. This instrument utilizes fiber-based evanescent-field cavity-ringdown spectroscopy, in combination with faceted prism microchannels. The combination of these techniques will increase the effective absorption path length by a factor of 10.sup.3 to 10.sup.4 (to .about.1-m), thereby providing unprecedented sensitivity using direct absorption. The coupling of high-sensitivity absorption with high-performance microfluidic separation will enable real-time sensing of biological agents in aqueous samples (including aerosol collector fluids) and will provide a general method with spectral fingerprint capability for detecting specific bio-agents.

  20. Early detection and intervention for attention-deficit/hyperactivity disorder.

    PubMed

    Sonuga-Barke, Edmund J S; Koerting, Johanna; Smith, Elizabeth; McCann, Donna C; Thompson, Margaret

    2011-04-01

    Attention-deficit/hyperactivity disorder (ADHD) is a high-cost/high-burden disorder. Early detection and intervention may prevent or ameliorate the development of the disorder and reduce its long-term impact. In this article, we set out a rationale for an early detection and intervention program. First, we highlight the costs of the condition and second, we discuss the limitations of the current treatments. We then outline the potential value of an early detection and intervention program. We review evidence on predictors of poor outcomes for early ADHD signs and discuss how these might allow us to target early intervention more cost-effectively. We then examine potential barriers to engagement with at-risk samples. This leads to a discussion of possible intervention approaches and how these could be improved. Finally, we describe the Program for Early Detection and Intervention for ADHD (PEDIA), a 5-year program of research supported by the UK National Institute for Health Research and conducted at the University of Southampton (Southampton, UK), which aims to develop and evaluate a strategy for early intervention.

  1. Bomb Detection System Study

    DTIC Science & Technology

    1965-01-01

    cause the reduction in vapor pressure. To determine whether an explosive can be detected thi ugh its * vapor, it is necessary to know the vapor pressures...Smokeless powders are explosives normally used in shotgun powders and can vary widely in composition. Nitrocellulose is the major :oomponent. Dinitrotoluene...will not be inclined to undertake the risky process except under very unusual circum- stances. Black powder is an obvious choice and has been so in

  2. Early detection for cases of enterovirus- and influenza-like illness through a newly established school-based syndromic surveillance system in Taipei, January 2010 ~ August 2011.

    PubMed

    Weng, Ting Chia; Chan, Ta Chien; Lin, Hsien Tang; Chang, Chia Kun Jasper; Wang, Wen Wen; Li, Zheng Rong Tiger; Cheng, Hao-Yuan; Chu, Yu-Roo; Chiu, Allen Wen-Hsiang; Yen, Muh-Yong; King, Chwan-Chuen

    2015-01-01

    School children may transmit pathogens with cluster cases occurring on campuses and in families. In response to the 2009 influenza A (H1N1) pandemic, Taipei City Government officials developed a School-based Infectious Disease Syndromic Surveillance System (SID-SSS). Teachers and nurses from preschools to universities in all 12 districts within Taipei are required to daily report cases of symptomatic children or sick leave requests through the SID-SSS. The pre-diagnosis at schools is submitted firstly as common pediatric disease syndrome-groups and re-submitted after confirmation by physicians. We retrieved these data from January 2010 to August 2011 for spatio-temporal analysis and evaluated the temporal trends with cases obtained from both the Emergency Department-based Syndromic Surveillance System (ED-SSS) and the Longitudinal Health Insurance Database 2005 (LHID2005). Through the SID-SSS, enterovirus-like illness (EVI) and influenza-like illness (ILI) were the two most reported syndrome groups (77.6% and 15.8% among a total of 19,334 cases, respectively). The pre-diagnosis judgments made by school teachers and nurses showed high consistency with physicians' clinical diagnoses for EVI (97.8%) and ILI (98.9%). Most importantly, the SID-SSS had better timeliness with earlier peaks of EVI and ILI than those in the ED-SSS. Furthermore, both of the syndrome groups in these two surveillance systems had the best correlation reaching 0.98 and 0.95, respectively (p<0.01). Spatio-temporal analysis observed the patterns of EVI and ILI both diffuse from the northern suburban districts to central Taipei, with ILI spreading faster. This novel system can identify early suspected cases of two important pediatric infections occurring at schools, and clusters from schools/families. It was also cost-effective (95.5% of the operation cost reduced and 59.7% processing time saved). The timely surveillance of mild EVI and ILI cases integrated with spatial analysis may help public

  3. Early Detection for Cases of Enterovirus- and Influenza-Like Illness through a Newly Established School-Based Syndromic Surveillance System in Taipei, January 2010 ~ August 2011

    PubMed Central

    Weng, Ting Chia; Chan, Ta Chien; Li, Zheng Rong Tiger; Cheng, Hao-Yuan; Chu, Yu-Roo; Chiu, Allen Wen-Hsiang; Yen, Muh-Yong; King, Chwan-Chuen

    2015-01-01

    School children may transmit pathogens with cluster cases occurring on campuses and in families. In response to the 2009 influenza A (H1N1) pandemic, Taipei City Government officials developed a School-based Infectious Disease Syndromic Surveillance System (SID-SSS). Teachers and nurses from preschools to universities in all 12 districts within Taipei are required to daily report cases of symptomatic children or sick leave requests through the SID-SSS. The pre-diagnosis at schools is submitted firstly as common pediatric disease syndrome-groups and re-submitted after confirmation by physicians. We retrieved these data from January 2010 to August 2011 for spatio-temporal analysis and evaluated the temporal trends with cases obtained from both the Emergency Department-based Syndromic Surveillance System (ED-SSS) and the Longitudinal Health Insurance Database 2005 (LHID2005). Through the SID-SSS, enterovirus-like illness (EVI) and influenza-like illness (ILI) were the two most reported syndrome groups (77.6% and 15.8% among a total of 19,334 cases, respectively). The pre-diagnosis judgments made by school teachers and nurses showed high consistency with physicians’ clinical diagnoses for EVI (97.8%) and ILI (98.9%). Most importantly, the SID-SSS had better timeliness with earlier peaks of EVI and ILI than those in the ED-SSS. Furthermore, both of the syndrome groups in these two surveillance systems had the best correlation reaching 0.98 and 0.95, respectively (p<0.01). Spatio-temporal analysis observed the patterns of EVI and ILI both diffuse from the northern suburban districts to central Taipei, with ILI spreading faster. This novel system can identify early suspected cases of two important pediatric infections occurring at schools, and clusters from schools/families. It was also cost-effective (95.5% of the operation cost reduced and 59.7% processing time saved). The timely surveillance of mild EVI and ILI cases integrated with spatial analysis may help public

  4. Early Wheel Train Damage Detection Using Wireless Sensor Network Antenna

    NASA Astrophysics Data System (ADS)

    Fazilah, A. F. M.; Azemi, S. N.; Azremi, A. A. H.; Soh, P. J.; Kamarudin, L. M.

    2018-03-01

    Antenna for a wireless sensor network for early wheel trains damage detection has successfully developed and fabricated with the aim to minimize the risk and increase the safety guaranty for train. Current antenna design is suffered in gain and big in size. For the sensor, current existing sensor only detect when the wheel malfunction. Thus, a compact microstrip patch antenna with operating frequency at 2.45GHz is design with high gain of 4.95dB will attach to the wireless sensor device. Simulation result shows that the antenna is working at frequency 2.45GHz and the return loss at -34.46dB are in a good agreement. The result also shows the good radiation pattern and almost ideal VSWR which is 1.04. The Arduino Nano, LM35DZ and ESP8266-07 Wi-Fi module is applied to the core system with capability to sense the temperature and send the data wirelessly to the cloud. An android application has been created to monitor the temperature reading based on the real time basis. The mainly focuses for the future improvement is by minimize the size of the antenna in order to make in more compact. In addition, upgrade an android application that can collect the raw data from cloud and make an alarm system to alert the loco pilot.

  5. Particle detection systems and methods

    DOEpatents

    Morris, Christopher L.; Makela, Mark F.

    2010-05-11

    Techniques, apparatus and systems for detecting particles such as muons and neutrons. In one implementation, a particle detection system employs a plurality of drift cells, which can be for example sealed gas-filled drift tubes, arranged on sides of a volume to be scanned to track incoming and outgoing charged particles, such as cosmic ray-produced muons. The drift cells can include a neutron sensitive medium to enable concurrent counting of neutrons. The system can selectively detect devices or materials, such as iron, lead, gold, uranium, plutonium, and/or tungsten, occupying the volume from multiple scattering of the charged particles passing through the volume and can concurrently detect any unshielded neutron sources occupying the volume from neutrons emitted therefrom. If necessary, the drift cells can be used to also detect gamma rays. The system can be employed to inspect occupied vehicles at border crossings for nuclear threat objects.

  6. Simplified HCC-ART score for highly sensitive detection of small-sized and early-stage hepatocellular carcinoma in the widely used Okuda, CLIP, and BCLC staging systems.

    PubMed

    Attallah, Abdelfattah M; Omran, Mohamed M; Attallah, Ahmed A; Abdelrazek, Mohamed A; Farid, Khaled; El-Dosoky, Ibrahim

    2017-04-01

    Small-sized HCC can be effectively cured by surgery with good clinical outcomes. A highly sensitive HCC α-fetoprotein routine test (HCC-ART) for HCC diagnosis as well as a simplied form of the HCC-ART were reported in the British Journal of Cancer. Here, we verified and studied the applicability of the HCC-ART to the detection of early-stage HCC. 341 cirrhotic patients and 318 HCC patients were included in this study. For each, the HCC-ART score was calculated, and then the sensitivity, specificity, and results of an ROC curve analysis were compared between the HCC-ART and AFP when these biomarkers were used to detect small-sized HCC. Different HCC-ART cutoffs were set for the detection of different tumor sizes. The HCC-ART (AUC = 0.871, 70% sensitivity, 97% specificity) and the simplified HCC-ART (AUC = 0.934, 82% sensitivity, 100% specificity) were found to have high predictive power when attempting to separate cirrhotic patients from those with small-sized HCC. The simplified HCC-ART score was superior to AFP for determining stages according to the early Okuda (0.950 AUC, 84% sensitivity, 99% specificity), CLIP (0.945 AUC, 84% sensitivity, 99% specificity), and BCLC (1.000 AUC, 100% sensitivity, 99% specificity) staging systems. The simplified HCC-ART score was more strongly correlated than AFP and other staging systems with HCC tumor size (P < 0.0001; r = 0.8). The HCC-ART is superior to AFP for diagnosing early-stage HCC. Due to its advantages of minimal variability and a wide continuous scale for assessing HCC severity, the simplified HCC-ART has the potential to be more widely used than the original HCC-ART.

  7. Randomness fault detection system

    NASA Technical Reports Server (NTRS)

    Russell, B. Don (Inventor); Aucoin, B. Michael (Inventor); Benner, Carl L. (Inventor)

    1996-01-01

    A method and apparatus are provided for detecting a fault on a power line carrying a line parameter such as a load current. The apparatus monitors and analyzes the load current to obtain an energy value. The energy value is compared to a threshold value stored in a buffer. If the energy value is greater than the threshold value a counter is incremented. If the energy value is greater than a high value threshold or less than a low value threshold then a second counter is incremented. If the difference between two subsequent energy values is greater than a constant then a third counter is incremented. A fault signal is issued if the counter is greater than a counter limit value and either the second counter is greater than a second limit value or the third counter is greater than a third limit value.

  8. Early Detection of Skin Cancer by Microtopography

    NASA Astrophysics Data System (ADS)

    del Carmen López-Pacheco, María; Acevedo-Martínez, Claudia; Pereira da Cunha Martins Costa, Manuel Filipe; Domínguez-Cherit, Judith; Pichardo, Patricia; Pérez-Zapata, Aura Judith; Ramón-Gallegos, Eva

    2004-09-01

    The objective of this work was to determine the ruggedness of the skin with benign and malignant lesions. Latex impressions were taken from lesions of skin's patients and were analyzed by the MICROTOP 03.MFC inspection system. For the melanoma lesion it was observed that the average rugosity of this tumor was increased 67% compared with the rugosity of healthy skin. These measures allow us to distinguish significantly from other tumors, as it is the case of the basal cell carcinoma (49%), and benign lesions as the epidermoid cyst (37%) and the seborrhea keratosis (4%). It was observed a direct relation between the rugosity and the malignancy of the lesions. These results indicate that the rugosity is a characteristic that could be useful in the diagnosis of skin cancer.

  9. Thermal neutron detection system

    DOEpatents

    Peurrung, Anthony J.; Stromswold, David C.

    2000-01-01

    According to the present invention, a system for measuring a thermal neutron emission from a neutron source, has a reflector/moderator proximate the neutron source that reflects and moderates neutrons from the neutron source. The reflector/moderator further directs thermal neutrons toward an unmoderated thermal neutron detector.

  10. NORSAR Detection Processing System.

    DTIC Science & Technology

    1987-05-31

    systems have been reliable. NTA/Lillestrom and Hamar will take a new initiative medio April regarding 04C. The line will be remeasured and if a certain...estimate of the ambient noise level at the site of the FINESA array, ground motion spectra were calculated for four time intervals. Two intervals were

  11. Centrifugal unbalance detection system

    DOEpatents

    Cordaro, Joseph V.; Reeves, George; Mets, Michael

    2002-01-01

    A system consisting of an accelerometer sensor attached to a centrifuge enclosure for sensing vibrations and outputting a signal in the form of a sine wave with an amplitude and frequency that is passed through a pre-amp to convert it to a voltage signal, a low pass filter for removing extraneous noise, an A/D converter and a processor and algorithm for operating on the signal, whereby the algorithm interprets the amplitude and frequency associated with the signal and once an amplitude threshold has been exceeded the algorithm begins to count cycles during a predetermined time period and if a given number of complete cycles exceeds the frequency threshold during the predetermined time period, the system shuts down the centrifuge.

  12. Power line detection system

    DOEpatents

    Latorre, Victor R.; Watwood, Donald B.

    1994-01-01

    A short-range, radio frequency (RF) transmitting-receiving system that provides both visual and audio warnings to the pilot of a helicopter or light aircraft of an up-coming power transmission line complex. Small, milliwatt-level narrowband transmitters, powered by the transmission line itself, are installed on top of selected transmission line support towers or within existing warning balls, and provide a continuous RF signal to approaching aircraft. The on-board receiver can be either a separate unit or a portion of the existing avionics, and can also share an existing antenna with another airborne system. Upon receipt of a warning signal, the receiver will trigger a visual and an audio alarm to alert the pilot to the potential power line hazard.

  13. Power line detection system

    DOEpatents

    Latorre, V.R.; Watwood, D.B.

    1994-09-27

    A short-range, radio frequency (RF) transmitting-receiving system that provides both visual and audio warnings to the pilot of a helicopter or light aircraft of an up-coming power transmission line complex. Small, milliwatt-level narrowband transmitters, powered by the transmission line itself, are installed on top of selected transmission line support towers or within existing warning balls, and provide a continuous RF signal to approaching aircraft. The on-board receiver can be either a separate unit or a portion of the existing avionics, and can also share an existing antenna with another airborne system. Upon receipt of a warning signal, the receiver will trigger a visual and an audio alarm to alert the pilot to the potential power line hazard. 4 figs.

  14. Radiation detection system

    DOEpatents

    Whited, R.C.

    A system for obtaining improved resolution in relatively thick semiconductor radiation detectors, such as HgI/sub 2/, which exhibit significant hole trapping. Two amplifiers are used: the first measures the charge collected and the second the contribution of the electrons to the charge collected. The outputs of the two amplifiers are utilized to unfold the total charge generated within the detector in response to a radiation event.

  15. Advances in pancreatic cancer research: moving towards early detection.

    PubMed

    He, Xiang-Yi; Yuan, Yao-Zong

    2014-08-28

    Pancreatic ductal adenocarcinoma (PDAC) is one of the most lethal forms of cancer. Substantial progress has been made in the understanding of the biology of pancreatic cancer, and advances in patient management have been significant. However, most patients (nearly 80%) who present with locally advanced or metastatic disease have an extremely poor prognosis. Survival is better for those with malignant disease localized to the pancreas, because surgical resection at present offers the only chance of cure. Therefore, the early detection of pancreatic cancer may benefit patients with PDAC. However, its low rate of incidence and the limitations of current screening strategies make early detection difficult. Recent advances in the understanding of the pathogenesis of PDAC suggest that it is possible to detect PDAC in early stages and even identify precursor lesions. The presence of new-onset diabetes mellitus in the early phase of pancreatic cancer may provide clues for its early diagnosis. Advances in the identification of novel circulating biomarkers including serological signatures, autoantibodies, epigenetic markers, circulating tumor cells and microRNAs suggest that they can be used as potential tools for the screening of precursors and early stage PDAC in the future. However, proper screening strategies based on effective screening methodologies need to be tested for clinical application.

  16. Ferromagnetic Objects Magnetovision Detection System.

    PubMed

    Nowicki, Michał; Szewczyk, Roman

    2013-12-02

    This paper presents the application of a weak magnetic fields magnetovision scanning system for detection of dangerous ferromagnetic objects. A measurement system was developed and built to study the magnetic field vector distributions. The measurements of the Earth's field distortions caused by various ferromagnetic objects were carried out. The ability for passive detection of hidden or buried dangerous objects and the determination of their location was demonstrated.

  17. Multicentre validation of the bedside paediatric early warning system score: a severity of illness score to detect evolving critical illness in hospitalised children

    PubMed Central

    2011-01-01

    Introduction The timely provision of critical care to hospitalised patients at risk for cardiopulmonary arrest is contingent upon identification and referral by frontline providers. Current approaches require improvement. In a single-centre study, we developed the Bedside Paediatric Early Warning System (Bedside PEWS) score to identify patients at risk. The objective of this study was to validate the Bedside PEWS score in a large patient population at multiple hospitals. Methods We performed an international, multicentre, case-control study of children admitted to hospital inpatient units with no limitations on care. Case patients had experienced a clinical deterioration event involving either an immediate call to a resuscitation team or urgent admission to a paediatric intensive care unit. Control patients had no events. The scores ranged from 0 to 26 and were assessed in the 24 hours prior to the clinical deterioration event. Score performance was assessed using the area under the receiver operating characteristic (AUCROC) curve by comparison with the retrospective rating of nurses and the temporal progression of scores in case patients. Results A total of 2,074 patients were evaluated at 4 participating hospitals. The median (interquartile range) maximum Bedside PEWS scores for the 12 hours ending 1 hour before the clinical deterioration event were 8 (5 to 12) in case patients and 2 (1 to 4) in control patients (P < 0.0001). The AUCROC curve (95% confidence interval) was 0.87 (0.85 to 0.89). In case patients, mean scores were 5.3 at 20 to 24 hours and 8.4 at 0 to 4 hours before the event (P < 0.0001). The AUCROC curve (95% CI) of the retrospective nurse ratings was 0.83 (0.81 to 0.86). This was significantly lower than that of the Bedside PEWS score (P < 0.0001). Conclusions The Bedside PEWS score identified children at risk for cardiopulmonary arrest. Scores were elevated and continued to increase in the 24 hours before the clinical deterioration event

  18. Kentucky's Statewide Early Childhood Professional Development System

    ERIC Educational Resources Information Center

    Rous, Beth; Grove, Jaime; Townley, Kim

    2007-01-01

    Public school systems have recently become major players in providing services for children in their early years. In addition, a number of other services are available to young children including child care, Head Start, and Early Head Start programs. The link between program quality and professional development of early care and education…

  19. Liquid biopsy for early detection of lung cancer.

    PubMed

    Hofman, Paul

    2017-01-01

    The possibility of complete recovery for a lung cancer patient depends on very early diagnosis, as it allows total surgical resection. Screening for this cancer in a high-risk population can be performed using a radiological approach, but this holds a certain number of limitations. Liquid biopsy could become an alternative and complementary screening approach to chest imaging for early diagnosis of lung cancer. Several circulating biomarkers indicative of lung cancer can be investigated in blood, such as circulating tumor cells, circulating free nucleic acids (RNA and DNA) and proteins. However, none of these biomarkers have yet been adopted in routine clinical practice and studies are ongoing to confirm or not the usefulness and practical interest in routine early diagnosis and screening for lung cancers. Several potential circulating biomarkers for the early detection of lung cancer exist. When coupled to thoracic imaging, these biomarkers must give diagnosis of a totally resectable lung cancer and potentially provide new recommendations for surveillance by imagery of high-risk populations without a detectable nodule. Optimization of the specificity and sensitivity of the detection methods as well as standardization of the techniques is essential before considering for daily practice a liquid biopsy as an early diagnostic tool, or possibly as a predictive test, of lung cancer.

  20. Strategies for early detection of resectable pancreatic cancer

    PubMed Central

    Okano, Keiichi; Suzuki, Yasuyuki

    2014-01-01

    Pancreatic cancer is difficult to diagnose at an early stage and generally has a poor prognosis. Surgical resection is the only potentially curative treatment for pancreatic carcinoma. To improve the prognosis of this disease, it is essential to detect tumors at early stages, when they are resectable. The optimal approach to screening for early pancreatic neoplasia has not been established. The International Cancer of the Pancreas Screening Consortium has recently finalized several recommendations regarding the management of patients who are at an increased risk of familial pancreatic cancer. In addition, there have been notable advances in research on serum markers, tissue markers, gene signatures, and genomic targets of pancreatic cancer. To date, however, no biomarkers have been established in the clinical setting. Advancements in imaging modalities touch all aspects of the clinical management of pancreatic diseases, including the early detection of pancreatic masses, their characterization, and evaluations of tumor resectability. This article reviews strategies for screening high-risk groups, biomarkers, and current advances in imaging modalities for the early detection of resectable pancreatic cancer. PMID:25170207

  1. A National Virtual Specimen Database for Early Cancer Detection

    NASA Technical Reports Server (NTRS)

    Crichton, Daniel; Kincaid, Heather; Kelly, Sean; Thornquist, Mark; Johnsey, Donald; Winget, Marcy

    2003-01-01

    Access to biospecimens is essential for enabling cancer biomarker discovery. The National Cancer Institute's (NCI) Early Detection Research Network (EDRN) comprises and integrates a large number of laboratories into a network in order to establish a collaborative scientific environment to discover and validate disease markers. The diversity of both the institutions and the collaborative focus has created the need for establishing cross-disciplinary teams focused on integrating expertise in biomedical research, computational and biostatistics, and computer science. Given the collaborative design of the network, the EDRN needed an informatics infrastructure. The Fred Hutchinson Cancer Research Center, the National Cancer Institute,and NASA's Jet Propulsion Laboratory (JPL) teamed up to build an informatics infrastructure creating a collaborative, science-driven research environment despite the geographic and morphology differences of the information systems that existed within the diverse network. EDRN investigators identified the need to share biospecimen data captured across the country managed in disparate databases. As a result, the informatics team initiated an effort to create a virtual tissue database whereby scientists could search and locate details about specimens located at collaborating laboratories. Each database, however, was locally implemented and integrated into collection processes and methods unique to each institution. This meant that efforts to integrate databases needed to be done in a manner that did not require redesign or re-implementation of existing system

  2. Sweet-spot training for early esophageal cancer detection

    NASA Astrophysics Data System (ADS)

    van der Sommen, Fons; Zinger, Svitlana; Schoon, Erik J.; de With, Peter H. N.

    2016-03-01

    Over the past decade, the imaging tools for endoscopists have improved drastically. This has enabled physicians to visually inspect the intestinal tissue for early signs of malignant lesions. Besides this, recent studies show the feasibility of supportive image analysis for endoscopists, but the analysis problem is typically approached as a segmentation task where binary ground truth is employed. In this study, we show that the detection of early cancerous tissue in the gastrointestinal tract cannot be approached as a binary segmentation problem and it is crucial and clinically relevant to involve multiple experts for annotating early lesions. By employing the so-called sweet spot for training purposes as a metric, a much better detection performance can be achieved. Furthermore, a multi-expert-based ground truth, i.e. a golden standard, enables an improved validation of the resulting delineations. For this purpose, besides the sweet spot we also propose another novel metric, the Jaccard Golden Standard (JIGS) that can handle multiple ground-truth annotations. Our experiments involving these new metrics and based on the golden standard show that the performance of a detection algorithm of early neoplastic lesions in Barrett's esophagus can be increased significantly, demonstrating a 10 percent point increase in the resulting F1 detection score.

  3. EARLY DETECTION MONITORING OF INVASIVE SPECIES IN GREAT LAKES HARBORS

    EPA Science Inventory

    The Great Ships Initiative (GSI) has asked for a presentation on designing harbor monitoring. Our research/development project on early detection provides some examples and lessons for GSI to consider in evaluating effectiveness of ballast water treatments; the presentation allo...

  4. Early Detection Research Network (EDRN) | Division of Cancer Prevention

    Cancer.gov

    http://edrn.nci.nih.gov/EDRN is a collaborative network that maintains comprehensive infrastructure and resources critical to the discovery, development and validation of biomarkers for cancer risk and early detection. The program comprises a public/private sector consortium to accelerate the development of biomarkers that will change medical practice, ensure data

  5. Why Ambiguity Detection Is a Predictor of Early Reading Skill

    ERIC Educational Resources Information Center

    Wankoff, Lorain Szabo; Cairns, Helen Smith

    2009-01-01

    This study was designed to determine the contributions of metalinguistic skill and psycholinguistic processing ability to children's ability to detect the ambiguity of sentences and the relationship among all three factors to early reading ability. A total of 20 first graders and 20 second graders were given tasks testing the following abilities:…

  6. Infrared light sensor applied to early detection of tooth decay

    NASA Astrophysics Data System (ADS)

    Benjumea, Eberto; Espitia, José; Díaz, Leonardo; Torres, Cesar

    2017-08-01

    The approach dentistry to dental care is gradually shifting to a model focused on early detection and oral-disease prevention; one of the most important methods of prevention of tooth decay is opportune diagnosis of decay and reconstruction. The present study aimed to introduce a procedure for early diagnosis of tooth decay and to compare result of experiment of this method with other common treatments. In this setup, a laser emitting infrared light is injected in core of one bifurcated fiber-optic and conduced to tooth surface and with the same bifurcated fiber the radiation reflected for the same tooth is collected and them conduced to surface of sensor that measures thermal and light frequencies to detect early signs of decay below a tooth surface, where demineralization is difficult to spot with x-ray technology. This device will can be used to diagnose tooth decay without any chemicals and rays such as high power lasers or X-rays.

  7. Multiple Biomarker Panels for Early Detection of Breast Cancer in Peripheral Blood

    PubMed Central

    Zhang, Fan; Deng, Youping; Drabier, Renee

    2013-01-01

    Detecting breast cancer at early stages can be challenging. Traditional mammography and tissue microarray that have been studied for early breast cancer detection and prediction have many drawbacks. Therefore, there is a need for more reliable diagnostic tools for early detection of breast cancer due to a number of factors and challenges. In the paper, we presented a five-marker panel approach based on SVM for early detection of breast cancer in peripheral blood and show how to use SVM to model the classification and prediction problem of early detection of breast cancer in peripheral blood. We found that the five-marker panel can improve the prediction performance (area under curve) in the testing data set from 0.5826 to 0.7879. Further pathway analysis showed that the top four five-marker panels are associated with signaling, steroid hormones, metabolism, immune system, and hemostasis, which are consistent with previous findings. Our prediction model can serve as a general model for multibiomarker panel discovery in early detection of other cancers. PMID:24371830

  8. Multiple biomarker panels for early detection of breast cancer in peripheral blood.

    PubMed

    Zhang, Fan; Deng, Youping; Drabier, Renee

    2013-01-01

    Detecting breast cancer at early stages can be challenging. Traditional mammography and tissue microarray that have been studied for early breast cancer detection and prediction have many drawbacks. Therefore, there is a need for more reliable diagnostic tools for early detection of breast cancer due to a number of factors and challenges. In the paper, we presented a five-marker panel approach based on SVM for early detection of breast cancer in peripheral blood and show how to use SVM to model the classification and prediction problem of early detection of breast cancer in peripheral blood. We found that the five-marker panel can improve the prediction performance (area under curve) in the testing data set from 0.5826 to 0.7879. Further pathway analysis showed that the top four five-marker panels are associated with signaling, steroid hormones, metabolism, immune system, and hemostasis, which are consistent with previous findings. Our prediction model can serve as a general model for multibiomarker panel discovery in early detection of other cancers.

  9. Early detection of fungi damage in citrus using NIR spectroscopy

    NASA Astrophysics Data System (ADS)

    Blasco, Jose; Ortiz, Coral; Sabater, Maria D.; Molto, Enrique

    2000-12-01

    Early detection of defects and diseases in fruit helps to correctly classify them and make more adequate decisions about the destination of the product: internal market, export or industry. An early fungi infection detection is especially important because a few infected fruits can disseminate the infection to a whole batch, causing great economic losses and affecting to further exports. Ensure products with excellent quality and absolute absence of fungi infections is particularly important in those batches for long conservation or to be exported. The main objective of this work is to detect the fungi infections before they can be visible. Near Infrared spectroscopy has been employed in this work, because it is a non-destructive technique and can be easily implemented on line due to the high speed and simplicity of the process.

  10. Development of communication networks and water quality early warning detection systems at drinking water utilities in the Ohio River Valley Basin.

    PubMed

    Schulte, J G; Vicory, A H

    2005-01-01

    Source water quality is of major concern to all drinking water utilities. The accidental introduction of contaminants to their source water is a constant threat to utilities withdrawing water from navigable or industrialized rivers. The events of 11 September, 2001 in the United States have heightened concern for drinking water utility security as their source water and finished water may be targets for terrorist acts. Efforts are underway in several parts of the United States to strengthen early warning capabilities. This paper will focus on those efforts in the Ohio River Valley Basin.

  11. Integrated multisensor perimeter detection systems

    NASA Astrophysics Data System (ADS)

    Kent, P. J.; Fretwell, P.; Barrett, D. J.; Faulkner, D. A.

    2007-10-01

    The report describes the results of a multi-year programme of research aimed at the development of an integrated multi-sensor perimeter detection system capable of being deployed at an operational site. The research was driven by end user requirements in protective security, particularly in threat detection and assessment, where effective capability was either not available or prohibitively expensive. Novel video analytics have been designed to provide robust detection of pedestrians in clutter while new radar detection and tracking algorithms provide wide area day/night surveillance. A modular integrated architecture based on commercially available components has been developed. A graphical user interface allows intuitive interaction and visualisation with the sensors. The fusion of video, radar and other sensor data provides the basis of a threat detection capability for real life conditions. The system was designed to be modular and extendable in order to accommodate future and legacy surveillance sensors. The current sensor mix includes stereoscopic video cameras, mmWave ground movement radar, CCTV and a commercially available perimeter detection cable. The paper outlines the development of the system and describes the lessons learnt after deployment in a pilot trial.

  12. Multimodal imaging system for dental caries detection

    NASA Astrophysics Data System (ADS)

    Liang, Rongguang; Wong, Victor; Marcus, Michael; Burns, Peter; McLaughlin, Paul

    2007-02-01

    Dental caries is a disease in which minerals of the tooth are dissolved by surrounding bacterial plaques. A caries process present for some time may result in a caries lesion. However, if it is detected early enough, the dentist and dental professionals can implement measures to reverse and control caries. Several optical, nonionized methods have been investigated and used to detect dental caries in early stages. However, there is not a method that can singly detect the caries process with both high sensitivity and high specificity. In this paper, we present a multimodal imaging system that combines visible reflectance, fluorescence, and Optical Coherence Tomography (OCT) imaging. This imaging system is designed to obtain one or more two-dimensional images of the tooth (reflectance and fluorescence images) and a three-dimensional OCT image providing depth and size information of the caries. The combination of two- and three-dimensional images of the tooth has the potential for highly sensitive and specific detection of dental caries.

  13. [Research on early fire detection with CO-CO2 FTIR-spectroscopy].

    PubMed

    Du, Jian-hua; Zhang, Ren-cheng; Huang, Xiang-ying; Gong, Xue; Zhang, Xiao-hua

    2007-05-01

    A new fire detection method is put forward based on the theory of FTIR spectroscopy through analyzing all kinds of detection methods, in which CO and CO2 are chosen as early fire detection objects, and an early fire experiment system has been set up. The concentration characters of CO and CO2 were obtained through early fire experiments including real alarm sources and nuisance alarm sources. In real alarm sources there are abundant CO and CO2 which change regularly. In nuisance alarm sources there is almost no CO. So it's feasible to reduce the false alarms and increase the sensitivity of early fire detectors through analyzing the concentration characters of CO and CO2.

  14. Early detection of ecosystem regime shifts: a multiple method evaluation for management application.

    PubMed

    Lindegren, Martin; Dakos, Vasilis; Gröger, Joachim P; Gårdmark, Anna; Kornilovs, Georgs; Otto, Saskia A; Möllmann, Christian

    2012-01-01

    Critical transitions between alternative stable states have been shown to occur across an array of complex systems. While our ability to identify abrupt regime shifts in natural ecosystems has improved, detection of potential early-warning signals previous to such shifts is still very limited. Using real monitoring data of a key ecosystem component, we here apply multiple early-warning indicators in order to assess their ability to forewarn a major ecosystem regime shift in the Central Baltic Sea. We show that some indicators and methods can result in clear early-warning signals, while other methods may have limited utility in ecosystem-based management as they show no or weak potential for early-warning. We therefore propose a multiple method approach for early detection of ecosystem regime shifts in monitoring data that may be useful in informing timely management actions in the face of ecosystem change.

  15. Early Detection of Ecosystem Regime Shifts: A Multiple Method Evaluation for Management Application

    PubMed Central

    Lindegren, Martin; Dakos, Vasilis; Gröger, Joachim P.; Gårdmark, Anna; Kornilovs, Georgs; Otto, Saskia A.; Möllmann, Christian

    2012-01-01

    Critical transitions between alternative stable states have been shown to occur across an array of complex systems. While our ability to identify abrupt regime shifts in natural ecosystems has improved, detection of potential early-warning signals previous to such shifts is still very limited. Using real monitoring data of a key ecosystem component, we here apply multiple early-warning indicators in order to assess their ability to forewarn a major ecosystem regime shift in the Central Baltic Sea. We show that some indicators and methods can result in clear early-warning signals, while other methods may have limited utility in ecosystem-based management as they show no or weak potential for early-warning. We therefore propose a multiple method approach for early detection of ecosystem regime shifts in monitoring data that may be useful in informing timely management actions in the face of ecosystem change. PMID:22808007

  16. Using Renyi entropy to detect early cardiac autonomic neuropathy.

    PubMed

    Cornforth, David J; Tarvainen, Mika P; Jelinek, Herbert F

    2013-01-01

    Cardiac Autonomic Neuropathy (CAN) is a disease that involves nerve damage leading to abnormal control of heart rate. CAN affects the correct operation of the heart and in turn leads to associated arrhythmias and heart attack. An open question is to what extent this condition is detectable by the measurement of Heart Rate Variability (HRV). An even more desirable option is to detect CAN in its early, preclinical stage, to improve treatment and outcomes. In previous work we have shown a difference in the Renyi spectrum between participants identified with well-defined CAN and controls. In this work we applied the multi-scale Renyi entropy for identification of early CAN in diabetes patients. Results suggest that Renyi entropy derived from a 20 minute, Lead-II ECG recording, forms a useful contribution to the detection of CAN even in the early stages of the disease. The positive α parameters (1 ≤ α ≤ 5) associated with the Renyi distribution indicated a significant difference (p < 0.00004) between controls and early CAN as well as definite CAN. This is a significant achievement given the simple nature of the information collected, and raises prospects of a simple screening test and improved outcomes of patients.

  17. Orbiter Interface Unit and Early Communication System

    NASA Technical Reports Server (NTRS)

    Cobbs, Ronald M.; Cooke, Michael P.; Cox, Gary L.; Ellenberger, Richard; Fink, Patrick W.; Haynes, Dena S.; Hyams, Buddy; Ling, Robert Y.; Neighbors, Helen M.; Phan, Chau T.; hide

    2004-01-01

    This report describes the Orbiter Interface Unit (OIU) and the Early Communication System (ECOMM), which are systems of electronic hardware and software that serve as the primary communication links for the International Space Station (ISS). When a space shuttle is at or near the ISS during assembly and resupply missions, the OIU sends groundor crew-initiated commands from the space shuttle to the ISS and relays telemetry from the ISS to the space shuttle s payload data systems. The shuttle then forwards the telemetry to the ground. In the absence of a space shuttle, the ECOMM handles communications between the ISS and Johnson Space Center via the Tracking and Data Relay Satellite System (TDRSS). Innovative features described in the report include (1) a "smart data-buffering algorithm that helps to preserve synchronization (and thereby minimize loss) of telemetric data between the OIU and the space-shuttle payload data interleaver; (2) an ECOMM antenna-autotracking algorithm that selects whichever of two phased-array antennas gives the best TDRSS signal and electronically steers that antenna to track the TDRSS source; and (3) an ECOMM radiation-latchup controller, which detects an abrupt increase in current indicative of radiation-induced latchup and temporarily turns off power to clear the latchup, restoring power after the charge dissipates.

  18. Sentinel lymph node detection in patients with early cervical cancer.

    PubMed

    Acharya, B C; Jihong, L

    2009-01-01

    Lymph node status is the most important independent prognostic factor in early stage cervical cancer. Intraoperative lymphatic mapping and sentinel lymph node detection have been increasingly evaluated in the treatment of a variety of solid tumors, particularly breast cancer and cutaneous melanoma. This study evaluated the feasibility of these procedures in patients undergoing radical hysterectomy with pelvic lymphadenectomy for early cervical cancer. A total of 30 patients with histologically diagnosed FIGO stage IA to IIA cervical cancer were enrolled to this study. They were scheduled to undergo radical abdominal hysterectomy and pelvic lymphadenectomy after injecting patent blue dye in cervix. A total of 60 SLNs (mean 2.5) were detected in 24 patients with detection rate of 80%. Bilateral SLNs were detected in 70.1% of cases. SLNs were identified in obturator and external iliac areas in 50% and 31.7%, respectively; no SLNs were discovered in the common iliac region. Seven patients (23.3%) had lymph node metastases; one of these had false negative SLN.The false negative rate and negative predictive value were 14.3% and 94.4%, respectively. SLN detection procedure with blue dye technique is a feasible procedure in cervical cancer. Patent blue dye is cheap, safe and effective tracer to detect sentinel node in carcinoma of cervix.

  19. Early detection and management of pulmonary arterial hypertension.

    PubMed

    Humbert, Marc; Gerry Coghlan, J; Khanna, Dinesh

    2012-12-01

    The long-term prognosis for patients with pulmonary arterial hypertension (PAH) remains poor, despite advances in treatment options that have been made in the past few decades. Recent evidence suggests that World Health Organization functional class I or II patients have significantly better long-term survival rates than patients in higher functional classes, thus providing a rationale for earlier diagnosis and treatment of PAH. However, early diagnosis is challenging and there is frequently a delay between symptom onset and diagnosis. Screening programmes play an important role in PAH detection and expert opinion favours echocardiographic screening of asymptomatic patients who may be predisposed to the development of PAH (i.e. those with systemic sclerosis or sickle cell disease), although current guidelines only recommend annual echocardiographic screening in symptomatic patients. This article reviews the currently available screening programmes, including their limitations, and describes alternative screening approaches that may identify more effectively those patients who require right heart catheterisation for a definitive PAH diagnosis.

  20. Early identification systems for emerging foodborne hazards.

    PubMed

    Marvin, H J P; Kleter, G A; Prandini, A; Dekkers, S; Bolton, D J

    2009-05-01

    This paper provides a non-exhausting overview of early warning systems for emerging foodborne hazards that are operating in the various places in the world. Special attention is given to endpoint-focussed early warning systems (i.e. ECDC, ISIS and GPHIN) and hazard-focussed early warning systems (i.e. FVO, RASFF and OIE) and their merit to successfully identify a food safety problem in an early stage is discussed. Besides these early warning systems which are based on monitoring of either disease symptoms or hazards, also early warning systems and/or activities that intend to predict the occurrence of a food safety hazard in its very beginning of development or before that are described. Examples are trend analysis, horizon scanning, early warning systems for mycotoxins in maize and/or wheat and information exchange networks (e.g. OIE and GIEWS). Furthermore, recent initiatives that aim to develop predictive early warning systems based on the holistic principle are discussed. The assumption of the researchers applying this principle is that developments outside the food production chain that are either directly or indirectly related to the development of a particular food safety hazard may also provide valuable information to predict the development of this hazard.

  1. Investigations of remote sensing techniques for early detection of Dutch elm disease

    NASA Technical Reports Server (NTRS)

    Hammerschlag, R. S.; Sopstyle, W. J.

    1975-01-01

    Several forms of aerial photography were pursued in quest of a technique which could provide early detection of Dutch elm disease. The two most promising techniques tested were multispectral photography with object enhancement and biband ratioing coupled with scanning microdensitometry. For practical purposes the multispectral system has the advantage of providing a readily interpretable image in a relatively short time. Laboratory studies indicated that less emphasis should be placed on the use of a red filter or the near infrared beyond 750 mm for early detection of stress within a single plant species. Color infrared film would be optimal when used for a long term detection of loss of plant vigor which results in a physical change in a plant canopy, but should find minimal practicality for early detection of specific sources of plant stress such as Dutch elm disease. Considerable discretion should be used when interpreting imagery on copy film because of loss of resolution and color definition.

  2. Infrasound array criteria for automatic detection and front velocity estimation of snow avalanches: towards a real-time early-warning system

    NASA Astrophysics Data System (ADS)

    Marchetti, E.; Ripepe, M.; Ulivieri, G.; Kogelnig, A.

    2015-11-01

    Avalanche risk management is strongly related to the ability to identify and timely report the occurrence of snow avalanches. Infrasound has been applied to avalanche research and monitoring for the last 20 years but it never turned into an operational tool to identify clear signals related to avalanches. We present here a method based on the analysis of infrasound signals recorded by a small aperture array in Ischgl (Austria), which provides a significant improvement to overcome this limit. The method is based on array-derived wave parameters, such as back azimuth and apparent velocity. The method defines threshold criteria for automatic avalanche identification by considering avalanches as a moving source of infrasound. We validate the efficiency of the automatic infrasound detection with continuous observations with Doppler radar and we show how the velocity of a snow avalanche in any given path around the array can be efficiently derived. Our results indicate that a proper infrasound array analysis allows a robust, real-time, remote detection of snow avalanches that is able to provide the number and the time of occurrence of snow avalanches occurring all around the array, which represent key information for a proper validation of avalanche forecast models and risk management in a given area.

  3. Artemisinin resistance containment project in Thailand. (I): Implementation of electronic-based malaria information system for early case detection and individual case management in provinces along the Thai-Cambodian border.

    PubMed

    Khamsiriwatchara, Amnat; Sudathip, Prayuth; Sawang, Surasak; Vijakadge, Saowanit; Potithavoranan, Thanapon; Sangvichean, Aumnuyphan; Satimai, Wichai; Delacollette, Charles; Singhasivanon, Pratap; Lawpoolsri, Saranath; Kaewkungwal, Jaranit

    2012-07-29

    The Bureau of Vector-borne Diseases, Ministry of Public Health, Thailand, has implemented an electronic Malaria Information System (eMIS) as part of a strategy to contain artemisinin resistance. The attempt corresponds to the WHO initiative, funded by the Bill & Melinda Gates Foundation, to contain anti-malarial drug resistance in Southeast Asia. The main objective of this study was to demonstrate the eMIS' functionality and outputs after implementation for use in the Thailand artemisinin-resistance containment project. The eMIS had been functioning since 2009 in seven Thai-Cambodian border provinces. The eMIS has covered 61 malaria posts/clinics, 27 Vector-borne Disease Units covering 12,508 hamlets at risk of malaria infections. The eMIS was designed as an evidence-based and near real-time system to capture data for early case detection, intensive case investigation, monitoring drug compliance and on/off-site tracking of malarial patients, as well as collecting data indicating potential drug resistance among patients. Data captured by the eMIS in 2008-2011 were extracted and presented. The core functionalities of the eMIS have been utilized by malaria staff at all levels, from local operational units to ministerial management. The eMIS case detection module suggested decreasing trends during 2009-2011; the number of malaria cases detected in the project areas over the years studied were 3818, 2695, and 2566, with sero-positive rates of 1.24, 0.98, and 1.16%, respectively. The eMIS case investigation module revealed different trends in weekly Plasmodium falciparum case numbers, when classified by responsible operational unit, local and migrant status, and case-detection type. It was shown that most Thai patients were infected within their own residential district, while migrants were infected either at their working village or from across the border. The data mapped in the system suggested that P. falciparum-infected cases and potential drug-resistant cases were

  4. Hearing aid malfunction detection system

    NASA Technical Reports Server (NTRS)

    Kessinger, R. L. (Inventor)

    1977-01-01

    A malfunction detection system for detecting malfunctions in electrical signal processing circuits is disclosed. Malfunctions of a hearing aid in the form of frequency distortion and/or inadequate amplification by the hearing aid amplifier, as well as weakening of the hearing aid power supply are detectable. A test signal is generated and a timed switching circuit periodically applies the test signal to the input of the hearing aid amplifier in place of the input signal from the microphone. The resulting amplifier output is compared with the input test signal used as a reference signal. The hearing aid battery voltage is also periodically compared to a reference voltage. Deviations from the references beyond preset limits cause a warning system to operate.

  5. Distributed Fiber Optic Sensors for Earthquake Detection and Early Warning

    NASA Astrophysics Data System (ADS)

    Karrenbach, M. H.; Cole, S.

    2016-12-01

    Fiber optic cables placed along pipelines, roads or other infrastructure provide dense sampling of passing seismic wavefields. Laser interrogation units illuminate the fiber over its entire length, and strain at desired points along the fiber can be determined from the reflected signal. Single-mode optical fibers up to 50 km in length can provide a distributed acoustic sensing system (DAS) where the acoustic bandwidth of each channel is limited only by the round-trip time over the length of the cable (0.0005 s for a 50 km cable). Using a 10 m spatial resolution results in 4000 channels sampled at 2.5 kHz spanning a 40 km-long fiber deployed along a pipeline. The inline strain field is averaged along the fiber over a 10 m section of the cable at each desired spatial sample, creating a virtual sensor location. Typically, a dynamic strain sensitivity of sub-nanometers within each gauge along the entire length of the fiber can be achieved. This sensitivity corresponds to a particle displacement figure of approximately -90 dB ms-2Hz-½. Such a fiber optic sensor is not as sensitive as long-period seismometers used in earthquake networks, but given the large number of channels, small to medium-sized earthquakes can be detected, depending on distance from the array, and can be located with precision through arrival time inversions. We show several examples of earthquake recordings using distributed fiber optic arrays that were deployed originally for other purposes. A 480 km long section of a pipeline in Turkey was actively monitored with a DAS fiber optic system for activities in the immediate vicinity of the pipeline. The densely spaced sensor array along the pipeline detected earthquakes of 3.6 - 7.2 magnitude range, centered near Van, Turkey. Secondly, a fiber optic system located along a rail line near the Salton Sea in California was used to create a smaller scale fiber optic sensor array, on which earthquakes with magnitudes 2.2 - 2.7 were recorded from epicenters

  6. Identifying Massive Runaway Stars by Detecting Infrared Bowshock Nebula: Four OB Stars and a New Massive Early-B Binary System

    NASA Astrophysics Data System (ADS)

    Sorber, Rebecca L.; Rebecca L. Sorber, Henry A. Kobulnicky, Daniel A. Dale, Matthew S. Povich, William T. Chick, Heather N. Wernke, Julian E. Andrews, Stephan Munari, Grace M. Olivier, Danielle Schurhammer

    2016-01-01

    Though the main sequence evolution of OB type stars is relatively well known, the mass loss rates for these stars are still highly uncertain. Some OB stars are gravitationally ejected from their birth sites, traveling at speeds of 30 km/s or more which results in a prominent bowshock nebulae. We identified OB bowshock candidates at low Galactic latitudes by visual inspection of the Wide-field Infrared Survey Explorer (WISE) 22-micron images. Each candidate was observed using the Longslit Spectrograph at the Wyoming Infrared Observatory (WIRO) 2.3 meter telescope. We present here the results from observing four such candidates, and all four are confirmed as early type stars: GO92.3191+0.0591 (B1V) (aka ALS11826), GO86.551014-1.0873935 (B2V; a probable short-period binary), G076.6921-2.4071 (B5V), and G075.5711-0.2558 (B0V) (aka HD 194303). These results enlarge the sample of candidate runaway massive stars hosting bowshocks and provide a promising sample of such objects for studying stellar mass loss. This work is supported by the National Science Foundation Grants AST-1063146 (REU), AST-1411851 (RUI), and AST-1412845.

  7. Portable Microleak-Detection System

    NASA Technical Reports Server (NTRS)

    Rivers, H. Kevin; Sikora, Joseph G.; Sankaran, Sankara N.

    2007-01-01

    The figure schematically depicts a portable microleak-detection system that has been built especially for use in testing hydrogen tanks made of polymer-matrix composite materials. (As used here, microleak signifies a leak that is too small to be detectable by the simple soap-bubble technique.) The system can also be used to test for microleaks in tanks that are made of other materials and that contain gases other than hydrogen. Results of calibration tests have shown that measurement errors are less than 10 percent for leak rates ranging from 0.3 to 200 cm3/min. Like some other microleak-detection systems, this system includes a vacuum pump and associated plumbing for sampling the leaking gas, and a mass spectrometer for analyzing the molecular constituents of the gas. The system includes a flexible vacuum chamber that can be attached to the outer surface of a tank or other object of interest that is to be tested for leakage (hereafter denoted, simply, the test object). The gas used in a test can be the gas or vapor (e.g., hydrogen in the original application) to be contained by the test object. Alternatively, following common practice in leak testing, helium can be used as a test gas. In either case, the mass spectrometer can be used to verify that the gas measured by the system is the test gas rather than a different gas and, hence, that the leak is indeed from the test object.

  8. Semi autonomous mine detection system

    SciT

    Douglas Few; Roelof Versteeg; Herman Herman

    2010-04-01

    CMMAD is a risk reduction effort for the AMDS program. As part of CMMAD, multiple instances of semi autonomous robotic mine detection systems were created. Each instance consists of a robotic vehicle equipped with sensors required for navigation and marking, a countermine sensors and a number of integrated software packages which provide for real time processing of the countermine sensor data as well as integrated control of the robotic vehicle, the sensor actuator and the sensor. These systems were used to investigate critical interest functions (CIF) related to countermine robotic systems. To address the autonomy CIF, the INL developed RIKmore » was extended to allow for interaction with a mine sensor processing code (MSPC). In limited field testing this system performed well in detecting, marking and avoiding both AT and AP mines. Based on the results of the CMMAD investigation we conclude that autonomous robotic mine detection is feasible. In addition, CMMAD contributed critical technical advances with regard to sensing, data processing and sensor manipulation, which will advance the performance of future fieldable systems. As a result, no substantial technical barriers exist which preclude – from an autonomous robotic perspective – the rapid development and deployment of fieldable systems.« less

  9. New technology for early detection of health threats

    NASA Astrophysics Data System (ADS)

    Southern, Šárka O.; Lilienthal, Gerald W.

    2008-04-01

    Governmental agencies charged with protecting the health of the population and agriculture have several main strategic objectives including the detection of harmful agents, the identification of vulnerable biological targets, the prediction of health outcomes and the development of countermeasures. New technologies are urgently needed in several critical areas of bio-chemical defense: economical and minimally invasive biosensors for field use in humans and other species important for agriculture and infrastructure, universal analytical platforms for broad-based, early warnings of threats and technologies guiding the development of countermeasures. A new technology called Stress Response Profiling (SRP) was recently developed by the Gaia Medical Institute. SRP provides a universal analytical platform for monitoring health status based on measurements of physiological stress. The platform is implemented through handheld devices that can be used for noninvasive detection of early-stage health problems. This paper summarizes SRP features, advantages and potential benefits for critical areas of homeland defense.

  10. Future Directions for the Early Detection of Recurrent Breast Cancer

    PubMed Central

    Schneble, Erika J.; Graham, Lindsey J.; Shupe, Matthew P.; Flynt, Frederick L.; Banks, Kevin P.; Kirkpatrick, Aaron D.; Nissan, Aviram; Henry, Leonard; Stojadinovic, Alexander; Shumway, Nathan M.; Avital, Itzhak; Peoples, George E.; Setlik, Robert F.

    2014-01-01

    The main goal of follow-up care after breast cancer treatment is the early detection of disease recurrence. In this review, we emphasize the multidisciplinary approach to this continuity of care from surgery, medical oncology, and radiology. Challenges within each setting are briefly addressed as a means of discussion for the future directions of an effective and efficient surveillance plan of post-treatment breast cancer care. PMID:24790657

  11. Mortality in children with early detected congenital central hypothyroidism.

    PubMed

    Zwaveling-Soonawala, Nitash; Naafs, Jolanda C; Verkerk, Paul H; van Trotsenburg, A S Paul

    2018-06-07

    Approximately 60-80% of patients with congenital central hypothyroidism (CH-C) have multiple pituitary hormone deficiencies (MPHD), making CH-C a potentially life-threatening disease. Data on mortality in CH-C patients, however, are lacking. To study mortality rate in early detected and treated pediatric CH-C patients in the Netherlands and to investigate whether causes of death were related to pituitary hormone deficiencies. Overall mortality rate, infant mortality rate and under-5 mortality rate were calculated in all children with CH-C detected by neonatal screening between 1-1-1995 and 1-1-2013. Medical charts were reviewed to establish causes of death. 139 children with CH-C were identified, of which 138 could be traced (82 MPHD/56 isolated CHC). Total observation time was 1414 years with a median follow up duration of 10.2 years. The overall mortality rate was 10.9% (15/138). Infant mortality rate (IMR) and under-5 mortality rate were 65.2/1000 (9/138) and 101.4/1000 (14/138), respectively, compared to an IMR of 4.7/1000 and under-5 mortality of 5.4/1000 live born children in the Netherlands during the same time period (p<0.0001). Main causes of death were severe congenital malformations in six patients, asphyxia in two patients, and congenital or early neonatal infection in two patients. Pituitary hormone deficiency was noted as cause of death in only one infant. We report an increased mortality rate in early detected CH-C patients which does not seem to be related to endocrine disease. This suggests that mortality due to pituitary insufficiency is low in an early detected and treated CH-C population.

  12. Early Detection of Progressive Adolescent Idiopathic Scoliosis: A Severity Index.

    PubMed

    Skalli, Wafa; Vergari, Claudio; Ebermeyer, Eric; Courtois, Isabelle; Drevelle, Xavier; Kohler, Remi; Abelin-Genevois, Kariman; Dubousset, Jean

    2017-06-01

    Early detection of progressive adolescent idiopathic scoliosis (AIS) was assessed based on 3D quantification of the deformity. Based on 3D quantitative description of scoliosis curves, the aim is to assess a specific phenotype that could be an early detectable severity index for progressive AIS. Early detection of progressive scoliosis is important for adapted treatment to limit progression. However, progression risk assessment is mainly based on the follow up, waiting for signs of rapid progression that generally occur during the growth peak. Sixty-five mild scoliosis (16 boys, 49 girls, Cobb Angle between 10 and 20°) with a Risser between 0 and 2 were followed from their first examination until a decision was made by the clinician, either considering the spine as stable at the end of growth (26 patients) or planning to brace because of progression (39 patients). Calibrated biplanar x-rays were performed and 3D reconstructions of the spine allowed calculating six local parameters related to main curve deformity. For progressive curve 3D phenotype assessment, data were compared with those previously assessed for 30 severe scoliosis (Cobb Angle > 35°), 17 scoliosis before brace (Cobb Angle > 29°) and 53 spines of nonscoliosis subjects. A predictive discriminant analysis was performed to assess similarity of mild scoliosis curves either to those of scoliosis or nonscoliosis spines, yielding a severity index (S-index). S-index value at first examination was compared with clinical outcome. At the first exam, 53 out of 65 predictions (82%) were in agreement with actual clinical outcome. Approximately, 89% of the curves that were predicted as progressive proved accurate. Although still requiring large scale validation, results are promising for early detection of progressive curves. 2.

  13. Detection of early changes in lung cell cytology by flow-systems analysis techniques. Progress report, July 1--December 31, 1977

    SciT

    Steinkamp, J.A.; Hansen, K.M.; Wilson, J.S.

    1978-04-01

    This report summarizes ongoing experiments to develop cytological and biochemical indicators for measuring damage to respiratory tract cells exposed by inhalation of environmental toxic agents. The specific goal of this project is to apply flow cytometric methods to analyze and detect changes in lung epithelium as a function of exposure to toxic agents such as those associated with the production of synthetic fuels from oil shale and coal. The objectives during the past 6 months were to complete modifications to the multiparameter cell separator by adding a krypton laser with an output capability of specific wavelengths ranging from the uvmore » to the ir; analyze and separate lung cells based on their DNA content; evaluate some new fluorescent DNA and protein stains; and treat hamster lung cells with proteolytic enzymes for increasing cell yield. Future experiments will involve the continued analysis and characterization of exfoliated lung cells based primarily on cellular DNA content, protein, morphological features, and specific enzyme activities; quantitation of macrophage activity; exposure of hamsters to toxic agents such as oil shale particulates and ozone; and continued analysis of cells based on DNA content. As this new technology becomes adapted to analyzing respiratory tract cells, the measurement of physical and biochemical cell properties as a function of exposure to toxic agents will be increased. This analytical approach is designed to assist in the establishment of guidelines for estimating risks to exposed humans.« less

  14. Road Anomalies Detection System Evaluation.

    PubMed

    Silva, Nuno; Shah, Vaibhav; Soares, João; Rodrigues, Helena

    2018-06-21

    Anomalies on road pavement cause discomfort to drivers and passengers, and may cause mechanical failure or even accidents. Governments spend millions of Euros every year on road maintenance, often causing traffic jams and congestion on urban roads on a daily basis. This paper analyses the difference between the deployment of a road anomalies detection and identification system in a “conditioned” and a real world setup, where the system performed worse compared to the “conditioned” setup. It also presents a system performance analysis based on the analysis of the training data sets; on the analysis of the attributes complexity, through the application of PCA techniques; and on the analysis of the attributes in the context of each anomaly type, using acceleration standard deviation attributes to observe how different anomalies classes are distributed in the Cartesian coordinates system. Overall, in this paper, we describe the main insights on road anomalies detection challenges to support the design and deployment of a new iteration of our system towards the deployment of a road anomaly detection service to provide information about roads condition to drivers and government entities.

  15. Tape Cassette Bacteria Detection System

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

  16. Detection of early seizures by diffuse optical tomography

    NASA Astrophysics Data System (ADS)

    Zhang, Tao; Hajihashemi, M. Reza; Zhou, Junli; Carney, Paul R.; Jiang, Huabei

    2015-03-01

    In epilepsy it has been challenging to detect early changes in brain activity that occurs prior to seizure onset and to map their origin and evolution for possible intervention. Besides, preclinical seizure experiments need to be conducted in awake animals with images reconstructed and displayed in real-time. We demonstrate using a rat model of generalized epilepsy that diffuse optical tomography (DOT) provides a unique functional neuroimaging modality for noninvasively and continuously tracking brain activities with high spatiotemporal resolution. We developed methods to conduct seizure experiments in fully awake rats using a subject-specific helmet and a restraining mechanism. For the first time, we detected early hemodynamic responses with heterogeneous patterns several minutes preceding the electroencephalographic seizure onset, supporting the presence of a "pre-seizure" state both in anesthetized and awake rats. Using a novel time-series analysis of scattering images, we show that the analysis of scattered diffuse light is a sensitive and reliable modality for detecting changes in neural activity associated with generalized seizure. We found widespread hemodynamic changes evolving from local regions of the bilateral cortex and thalamus to the entire brain, indicating that the onset of generalized seizures may originate locally rather than diffusely. Together, these findings suggest DOT represents a powerful tool for mapping early seizure onset and propagation pathways.

  17. Detection of early changes in lung-cell cytology by flow-systems analysis techniques. Progress report, January 1--June 30, 1976

    SciT

    Steinkamp, J. A.; Hansen, K. M.; Wilson, J. S.

    1976-08-01

    This report summarizes results of preliminary experiments to develop cytological and biochemical indicators for estimating damage to respiratory epithelium exposed to toxic agents associated with the by-products of nonnuclear energy production using advanced flow-systems cell-analysis technologies. Since initiation of the program one year ago, progress has been made in obtaining adequate numbers of exfoliated lung cells from the Syrian hamster for flow analysis; cytological techniques developed on human exfoliated gynecological samples have been adapted to hamster lung epithelium for obtaining single-cell suspensions; and lung-cell samples have been initially characterized based on DNA content, total protein, nuclear and cytoplasmic size, andmore » multiangle light-scatter measurements. Preliminary results from measurements of the above parameters which recently became available are described in this report. As the flow-systems technology is adapted further to analysis of exfoliated lung cells, measurements of changes in physical and biochemical cellular properties as a function of exposure to toxic agents will be performed.« less

  18. Genetics and Early Detection in Idiopathic Pulmonary Fibrosis

    PubMed Central

    Putman, Rachel K.; Rosas, Ivan O.

    2014-01-01

    Genetic studies hold promise in helping to identify patients with early idiopathic pulmonary fibrosis (IPF). Recent studies using chest computed tomograms (CTs) in smokers and in the general population have demonstrated that imaging abnormalities suggestive of an early stage of pulmonary fibrosis are not uncommon and are associated with respiratory symptoms, physical examination abnormalities, and physiologic decrements expected, but less severe than those noted in patients with IPF. Similarly, recent genetic studies have demonstrated strong and replicable associations between a common promoter polymorphism in the mucin 5B gene (MUC5B) and both IPF and the presence of abnormal imaging findings in the general population. Despite these findings, it is important to note that the definition of early-stage IPF remains unclear, limited data exist to definitively connect abnormal imaging findings to IPF, and genetic studies assessing early-stage pulmonary fibrosis remain in their infancy. In this perspective we provide updated information on interstitial lung abnormalities and their connection to IPF. We summarize information on the genetics of pulmonary fibrosis by focusing on the recent genetic findings of MUC5B. Finally, we discuss the implications of these findings and suggest a roadmap for the use of genetics in the detection of early IPF. PMID:24547893

  19. Endoscopic tri-modal imaging for detection of early neoplasia in Barrett's oesophagus: a multi-centre feasibility study using high-resolution endoscopy, autofluorescence imaging and narrow band imaging incorporated in one endoscopy system.

    PubMed

    Curvers, W L; Singh, R; Song, L-M Wong-Kee; Wolfsen, H C; Ragunath, K; Wang, K; Wallace, M B; Fockens, P; Bergman, J J G H M

    2008-02-01

    To investigate the diagnostic potential of endoscopic tri-modal imaging and the relative contribution of each imaging modality (i.e. high-resolution endoscopy (HRE), autofluorescence imaging (AFI) and narrow-band imaging (NBI)) for the detection of early neoplasia in Barrett's oesophagus. Prospective multi-centre study. Tertiary referral centres. 84 Patients with Barrett's oesophagus. The Barrett's oesophagus was inspected with HRE followed by AFI. All lesions detected with HRE and/or AFI were subsequently inspected in detail by NBI for the presence of abnormal mucosal and/or microvascular patterns. Biopsies were obtained from all suspicious lesions for blinded histopathological assessment followed by random biopsies. (1) Number of patients with early neoplasia diagnosed by HRE and AFI; (2) number of lesions with early neoplasia detected with HRE and AFI; and (3) reduction of false positive AFI findings after NBI. Per patient analysis: AFI identified all 16 patients with early neoplasia identified with HRE and detected an additional 11 patients with early neoplasia that were not identified with HRE. In three patients no abnormalities were seen but random biopsies revealed HGIN. After HRE inspection, AFI detected an additional 102 lesions; 19 contained HGIN/EC (false positive rate of AFI after HRE: 81%). Detailed inspection with NBI reduced this false positive rate to 26%. In this international multi-centre study, the addition of AFI to HRE increased the detection of both the number of patients and the number of lesions with early neoplasia in patients with Barrett's oesophagus. The false positive rate of AFI was reduced after detailed inspection with NBI.

  20. APDS: the autonomous pathogen detection system.

    PubMed

    Hindson, Benjamin J; Makarewicz, Anthony J; Setlur, Ujwal S; Henderer, Bruce D; McBride, Mary T; Dzenitis, John M

    2005-04-15

    We have developed and tested a fully autonomous pathogen detection system (APDS) capable of continuously monitoring the environment for airborne biological threat agents. The system was developed to provide early warning to civilians in the event of a bioterrorism incident and can be used at high profile events for short-term, intensive monitoring or in major public buildings or transportation nodes for long-term monitoring. The APDS is completely automated, offering continuous aerosol sampling, in-line sample preparation fluidics, multiplexed detection and identification immunoassays, and nucleic acid-based polymerase chain reaction (PCR) amplification and detection. Highly multiplexed antibody-based and duplex nucleic acid-based assays are combined to reduce false positives to a very low level, lower reagent costs, and significantly expand the detection capabilities of this biosensor. This article provides an overview of the current design and operation of the APDS. Certain sub-components of the ADPS are described in detail, including the aerosol collector, the automated sample preparation module that performs multiplexed immunoassays with confirmatory PCR, and the data monitoring and communications system. Data obtained from an APDS that operated continuously for 7 days in a major U.S. transportation hub is reported.

  1. [Early detection of cervical cancer in Chile: time for change].

    PubMed

    Léniz Martelli, Javiera; Van De Wyngard, Vanessa; Lagos, Marcela; Barriga, María Isabel; Puschel Illanes, Klaus; Ferreccio Readi, Catterina

    2014-08-01

    Mortality rates for cervical cancer (CC) in Chile are higher than those of developed countries and it has an unequal socioeconomic distribution. The recognition of human papilloma virus (HPV) as the causal agent of cervical cancer in the early 80's changed the prevention paradigms. Current goals are to prevent HPV infection by vaccination before the onset of sexual activity and to detect HPV infection in women older than 30 years. This article reviews CC prevention and early detection methods, discusses relevant evidence to support a change in Chile and presents an innovation proposal. A strategy of primary screening based on HPV detection followed by triage of HPV-positive women by colposcopy in primary care or by cytological or molecular reflex testing is proposed. Due to the existence in Chile of a well-organized nationwide CC prevention program, the replacement of a low-sensitivity screening test such as the Papanicolau test with a highly sensitive one such as HPV detection, could quickly improve the effectiveness of the program. The program also has a network of personnel qualified to conduct naked-eye inspections of the cervix, who could easily be trained to perform triage colposcopy. The incorporation of new prevention strategies could reduce the deaths of Chilean women and correct inequities.

  2. Progress towards design elements for a Great Lakes-wide aquatic invasive species early detection network

    EPA Science Inventory

    Great Lakes coastal systems are vulnerable to introduction of a wide variety of non-indigenous species (NIS), and the desire to effectively respond to future invaders is prompting efforts towards establishing a broad early-detection network. Such a network requires statistically...

  3. Aquatic invasive species early detection in the Great Lakes: Lessons concerning strategy

    EPA Science Inventory

    Great Lakes coastal systems are vulnerable to introduction of a wide variety of non-indigenous species (NIS), and the desire to effectively respond to future invaders is prompting efforts towards establishing a broad early-detection network. Such a network requires statistically...

  4. All-optical photoacoustic imaging and detection of early-stage dental caries

    NASA Astrophysics Data System (ADS)

    Sampathkumar, Ashwin; Hughes, David A.; Longbottom, Chris; Kirk, Katherine J.

    2015-02-01

    Dental caries remain one of the most common oral diseases in the world. Current detection methods, such as dental explorer and X-ray radiography, suffer from poor sensitivity and specificity at the earliest (and reversible) stages of the disease because of the small size (< 100 microns) of early-stage lesions. We have developed a fine-resolution (480 nm), ultra-broadband (1 GHz), all-optical photoacoustic imaging (AOPAI) system to image and detect early stages of tooth decay. This AOPAI system provides a non-contact, non-invasive and non-ionizing means of detecting early-stage dental caries. Ex-vivo teeth exhibiting early-stage, white-spot lesions were imaged using AOPAI. Experimental scans targeted each early-stage lesion and a reference healthy enamel region. Photoacoustic (PA) signals were generated in the tooth using a 532-nm pulsed laser and the light-induced broadband ultrasound signal was detected at the surface of the tooth with an optical path-stabilized Michelson interferometer operating at 532 nm. The measured time-domain signal was spatially resolved and back-projected to form 2D and 3D maps of the lesion using k-wave reconstruction methods. Experimental data collected from areas of healthy and diseased enamel indicate that the lesion generated a larger PA response compared to healthy enamel. The PA-signal amplitude alone was able to detect a lesion on the surface of the tooth. However, time- reversal reconstructions of the PA scans also quantitatively depicted the depth of the lesion. 3D PA reconstruction of the diseased tooth indicated a sub-surface lesion at a depth of 0.6 mm, in addition to the surface lesion. These results suggest that our AOPAI system is well suited for rapid clinical assessment of early-stage dental caries. An overview of the AOPAI system, fine-resolution PA and histology results of diseased and healthy teeth will be presented.

  5. Lightning Protection and Detection System

    NASA Technical Reports Server (NTRS)

    Mielnik, John J. (Inventor); Woodard, Marie (Inventor); Smith, Laura J. (Inventor); Wang, Chuantong (Inventor); Koppen, Sandra V. (Inventor); Dudley, Kenneth L. (Inventor); Szatkowski, George N. (Inventor); Nguyen, Truong X. (Inventor); Ely, Jay J. (Inventor)

    2017-01-01

    A lightning protection and detection system includes a non-conductive substrate material of an apparatus; a sensor formed of a conductive material and deposited on the non-conductive substrate material of the apparatus. The sensor includes a conductive trace formed in a continuous spiral winding starting at a first end at a center region of the sensor and ending at a second end at an outer corner region of the sensor, the first and second ends being open and unconnected. An electrical measurement system is in communication with the sensor and receives a resonant response from the sensor, to perform detection, in real-time, of lightning strike occurrences and damage therefrom to the sensor and the non-conductive substrate material.

  6. Tsunami Generation Modelling for Early Warning Systems

    NASA Astrophysics Data System (ADS)

    Annunziato, A.; Matias, L.; Ulutas, E.; Baptista, M. A.; Carrilho, F.

    2009-04-01

    In the frame of a collaboration between the European Commission Joint Research Centre and the Institute of Meteorology in Portugal, a complete analytical tool to support Early Warning Systems is being developed. The tool will be part of the Portuguese National Early Warning System and will be used also in the frame of the UNESCO North Atlantic Section of the Tsunami Early Warning System. The system called Tsunami Analysis Tool (TAT) includes a worldwide scenario database that has been pre-calculated using the SWAN-JRC code (Annunziato, 2007). This code uses a simplified fault generation mechanism and the hydraulic model is based on the SWAN code (Mader, 1988). In addition to the pre-defined scenario, a system of computers is always ready to start a new calculation whenever a new earthquake is detected by the seismic networks (such as USGS or EMSC) and is judged capable to generate a Tsunami. The calculation is performed using minimal parameters (epicentre and the magnitude of the earthquake): the programme calculates the rupture length and rupture width by using empirical relationship proposed by Ward (2002). The database calculations, as well the newly generated calculations with the current conditions are therefore available to TAT where the real online analysis is performed. The system allows to analyze also sea level measurements available worldwide in order to compare them and decide if a tsunami is really occurring or not. Although TAT, connected with the scenario database and the online calculation system, is at the moment the only software that can support the tsunami analysis on a global scale, we are convinced that the fault generation mechanism is too simplified to give a correct tsunami prediction. Furthermore short tsunami arrival times especially require a possible earthquake source parameters data on tectonic features of the faults like strike, dip, rake and slip in order to minimize real time uncertainty of rupture parameters. Indeed the earthquake

  7. Nucleic acid detection system and method for detecting influenza

    DOEpatents

    Cai, Hong; Song, Jian

    2015-03-17

    The invention provides a rapid, sensitive and specific nucleic acid detection system which utilizes isothermal nucleic acid amplification in combination with a lateral flow chromatographic device, or DNA dipstick, for DNA-hybridization detection. The system of the invention requires no complex instrumentation or electronic hardware, and provides a low cost nucleic acid detection system suitable for highly sensitive pathogen detection. Hybridization to single-stranded DNA amplification products using the system of the invention provides a sensitive and specific means by which assays can be multiplexed for the detection of multiple target sequences.

  8. UWB based low-cost and non-invasive practical breast cancer early detection

    NASA Astrophysics Data System (ADS)

    Vijayasarveswari, V.; Khatun, S.; Fakir, M. M.; Jusoh, M.; Ali, S.

    2017-03-01

    Breast cancer is one of the main causes of women death worldwide. Breast tumor is an early stage of cancer that locates in cells of a human breast. As there is no remedy, early detection is crucial. Towards this, Ultra-Wideband (UWB) is a prominent candidate. It is a wireless communication technology which can achieve high bandwidth with low power utilization. UWB is suitable to be used for short range communication systems including breast cancer detection since it is secure, non-invasive and human health friendly. This paper presents the low-cost and non-invasive early breast cancer detection strategy using UWB sensor (or antenna). Emphasis is given here to detect breast tumor in 2D and 3D environments. The developed system consisted of hardware and software. Hardware included UWB transceiver and a pair of home-made directional sensor/antenna. The software included feed-forward back propagation Neural Network (NN) module to detect the tumor existence, size and location along with soft interface between software and hardware. Forward scattering technique was used by placing two sensors diagonally opposite sides of a breast phantom. UWB pulses were transmitted from one side of phantom and received from other side, controlled by the software interface in PC environment. Collected received signals were then fed into the NN module for training, testing and validation. The system exhibited detection efficiency on tumor existence, location (x, y, z), and size were approximately 100%, (78.17%, 70.66%, 92.46%), 85.86% respectively. The proposed UWB based early breast cancer detection system could be more practical with low-cost, user friendly and non-harmful features. This project may help users to monitor their breast health regularly at their home.

  9. Development of Mechanochemically Active Polymers for Early Damage Detection

    NASA Astrophysics Data System (ADS)

    Zou, Jin

    Identification of early damage in polymer composite materials is of significant importance so that preventative measures can be taken before the materials reach catastrophic failure. Scientists have been developing damage detection technologies over many years and recently, mechanophore-based polymers, in which mechanical energy is translated to activate a chemical transformation, have received increasing attention. More specifically, the damage can be made detectable by mechanochromic polymers, which provide a visible color change upon the scission of covalent bonds under stress. This dissertation focuses on the study of a novel self-sensing framework for identifying early and in-situ damage by employing unique stress-sensing mechanophores. Two types of mechanophores, cyclobutane and cyclooctane, were utilized, and the former formed from cinnamoyl moeities and the latter formed from anthracene upon photodimerization. The effects on the thermal and mechanical properties with the addition of the cyclobutane-based polymers into epoxy matrices were investigated. The emergence of cracks was detected by fluorescent signals at a strain level right after the yield point of the polymer blends, and the fluorescence intensified with the accumulation of strain. Similar to the mechanism of fluorescence emission from the cleavage of cyclobutane, the cyclooctane moiety generated fluorescent emission with a higher quantum yield upon cleavage. The experimental results also demonstrated the success of employing the cyclooctane type mechanophore as a potential force sensor, as the fluorescence intensification was correlated with the strain increase.

  10. Early Detection of Chronic Obstructive Pulmonary Disease in Primary Care.

    PubMed

    Kobayashi, Seiichi; Hanagama, Masakazu; Yanai, Masaru

    2017-12-01

    Objective To evaluate the effectiveness of an early detection program for chronic obstructive pulmonary disease (COPD) in a primary care setting in Japan. Methods Participants of ≥40 years of age who regularly visited a general practitioner's clinic due to chronic disease were asked to complete a COPD screening questionnaire (COPD Population Screener; COPD-PS) and undergo simplified spirometry using a handheld spirometric device. Patients who showed possible COPD were referred to a respiratory specialist and underwent a detailed examination that included spirometry and chest radiography. Results A total of 111 patients with possible COPD were referred for close examination. Among these patients, 27 patients were newly diagnosed with COPD. The patients with COPD were older, had lower BMI values, and had a longer smoking history in comparison to non-COPD patients. COPD patients also had more comorbid conditions. A diagnosis of COPD was significantly associated with a high COPD-PS score (p<0.001) and the detection of possible airflow limitation evaluated by the handheld spirometric device (p<0.01). An ROC curve analysis demonstrated that 5 points was the best COPD-PS cut-off value for the diagnosis of COPD. The combination of both tools showed 40.7% of sensitivity and 96.4% of specificity. Conclusion The use of the COPD-PS plus a handheld spirometric device could facilitate the early detection of undiagnosed COPD in primary care.

  11. Early optical detection of cerebral edema in vivo.

    PubMed

    Gill, Amandip S; Rajneesh, Kiran F; Owen, Christopher M; Yeh, James; Hsu, Mike; Binder, Devin K

    2011-02-01

    Cerebral edema is a significant cause of morbidity and mortality in diverse disease states. Currently, the means to detect progressive cerebral edema in vivo includes the use of intracranial pressure (ICP) monitors and/or serial radiological studies. However, ICP measurements exhibit a high degree of variability, and ICP monitors detect edema only after it becomes sufficient to significantly raise ICP. The authors report the development of 2 distinct minimally invasive fiberoptic near-infrared (NIR) techniques able to directly detect early cerebral edema. Cytotoxic brain edema was induced in adult CD1 mice via water intoxication by intraperitoneal water administration (30% body weight intraperitoneally). An implantable dual-fiberoptic probe was stereotactically placed into the cerebral cortex and connected to optical source and detector hardware. Optical sources consisted of either broadband halogen illumination or a single-wavelength NIR laser diode, and the detector was a sensitive NIR spectrometer or optical power meter. In one subset of animals, a left-sided craniectomy was performed to obtain cortical biopsies for water-content determination to verify cerebral edema. In another subset of animals, an ICP transducer was placed on the contralateral cortex, which was synchronized to a computer and time stamped. Using either broadband illumination with NIR spectroscopy or single-wavelength laser diode illumination with optical power meter detection, the authors detected a reduction in NIR optical reflectance during early cerebral edema. The time intervals between water injection (Time Point 0), optical trigger (defined as a 2-SD change in optical reflectance from baseline), and defined threshold ICP values of 10, 15 and 20 mm Hg were calculated. Reduction in NIR reflectance occurred significantly earlier than any of the ICP thresholds (p < 0.001). Saline-injected control mice exhibited a steady baseline optical signal. There was a significant correlation between

  12. Early warning signals detect critical impacts of experimental warming.

    PubMed

    Jarvis, Lauren; McCann, Kevin; Tunney, Tyler; Gellner, Gabriel; Fryxell, John M

    2016-09-01

    Earth's surface temperatures are projected to increase by ~1-4°C over the next century, threatening the future of global biodiversity and ecosystem stability. While this has fueled major progress in the field of physiological trait responses to warming, it is currently unclear whether routine population monitoring data can be used to predict temperature-induced population collapse. Here, we integrate trait performance theory with that of critical tipping points to test whether early warning signals can be reliably used to anticipate thermally induced extinction events. We find that a model parameterized by experimental growth rates exhibits critical slowing down in the vicinity of an experimentally tested critical threshold, suggesting that dynamical early warning signals may be useful in detecting the potentially precipitous onset of population collapse due to global climate change.

  13. Multifocal visual evoked potentials for early glaucoma detection.

    PubMed

    Weizer, Jennifer S; Musch, David C; Niziol, Leslie M; Khan, Naheed W

    2012-07-01

    To compare multifocal visual evoked potentials (mfVEP) with other detection methods in early open-angle glaucoma. Ten patients with suspected glaucoma and 5 with early open-angle glaucoma underwent mfVEP, standard automated perimetry (SAP), short-wave automated perimetry, frequency-doubling technology perimetry, and nerve fiber layer optical coherence tomography. Nineteen healthy control subjects underwent mfVEP and SAP for comparison. Comparisons between groups involving continuous variables were made using independent t tests; for categorical variables, Fisher's exact test was used. Monocular mfVEP cluster defects were associated with an increased SAP pattern standard deviation (P = .0195). Visual fields that showed interocular mfVEP cluster defects were more likely to also show superior quadrant nerve fiber layer thinning by OCT (P = .0152). Multifocal visual evoked potential cluster defects are associated with a functional and an anatomic measure that both relate to glaucomatous optic neuropathy. Copyright 2012, SLACK Incorporated.

  14. Early Attempts to Detect the Neutrino at the Cavendish Laboratory

    NASA Astrophysics Data System (ADS)

    Navarro, Jaume

    2006-03-01

    In the 1920s and early 1930s the Cavendish Laboratory in Cambridge was preeminent in experimental research on radioactivity and nuclear physics, with theoretical physics playing a subsidiary role in guiding, but not determining the course of experimental research. Soon after Wolfgang Pauli (1900 1958) proposed his neutrino hypothesis in 1930 to preserve conservation of energy and momentum in beta decay, experiments the first of their kind were carried out in the Cavendish Laboratory to detect Pauli’s elusive particle, but they were abandoned in 1936. I trace these early attempts and suggest reasons for their abandonment, which may contribute to an understanding of the complex way in which theoretical entities are accepted by physicists.

  15. Compensated intruder-detection systems

    DOEpatents

    McNeilly, David R.; Miller, William R.

    1984-01-01

    Intruder-detection systems in which intruder-induced signals are transmitted through a medium also receive spurious signals induced by changes in a climatic condition affecting the medium. To combat this, signals received from the detection medium are converted to a first signal. The system also provides a reference signal proportional to climate-induced changes in the medium. The first signal and the reference signal are combined for generating therefrom an output signal which is insensitive to the climatic changes in the medium. An alarm is energized if the output signal exceeds a preselected value. In one embodiment, an acoustic cable is coupled to a fence to generate a first electrical signal proportional to movements thereof. False alarms resulting from wind-induced movements of the fence (detection medium) are eliminated by providing an anemometer-driven voltage generator to provide a reference voltage proportional to the velocity of wind incident on the fence. An analog divider receives the first electrical signal and the reference signal as its numerator and denominator inputs, respectively, and generates therefrom an output signal which is insensitive to the wind-induced movements in the fence.

  16. Early detection of invasive plants: principles and practices

    Welch, Bradley A.; Geissler, Paul H.; Latham, Penelope

    2014-01-01

    Invasive plants infest an estimated 2.6 million acres of the 83 million acres managed by the National Park Service (NPS) in the United States. The consequences of these invasions present a significant challenge for the NPS to manage the agency’s natural resources “unimpaired for the enjoyment of future generations.” More NPS lands are infested daily despite diligent efforts to curtail the problem. Impacts from invasive species have been realized in most parks, resulting in an expressed need to control existing infestations and restore affected ecosystems. There is a growing urgency in the NPS and other resource management organizations to be proactive. The NPS I&M Program, in collaboration with the U.S. Geological Survey (USGS) Status and Trends Program, compiled this document to provide guidance and insight to parks and other natural areas engaged in developing early-detection monitoring protocols for invasive plants. While several rapid response frameworks exist, there is no consistent or comprehensive guidance informing the active detection of nonnative plants early in the invasion process. Early-detection was selected as a primary focus for invasive-species monitoring because, along with rapid response, it is a key strategy for successful management of invasive species. Eradication efforts are most successful on small infestations (that is less than 1 hectare) and become less successful as infestation size increases, to the point that eradication is unlikely for large (that is greater than 1,000 hectares) populations of invasive plants. This document provides guidance for natural resource managers wishing to detect invasive plants early through an active, directed monitoring program. It has a Quick-Start Guide to direct readers to specific chapters and text relevant to their needs. Decision trees and flow charts assist the reader in deciding what methods to choose and when to use them. This document is written in a modular format to accommodate use of

  17. The Sargassum Early Advisory System (SEAS)

    NASA Astrophysics Data System (ADS)

    Armstrong, D.; Gallegos, S. C.

    2016-02-01

    The Sargassum Early Advisory System (SEAS) web-app was designed to automatically detect Sargassum at sea, forecast movement of the seaweed, and alert users of potential landings. Inspired to help address the economic hardships caused by large landings of Sargassum, the web app automates and enhances the manual tasks conducted by the SEAS group of Texas A&M University at Galveston. The SEAS web app is a modular, mobile-friendly tool that automates the entire workflow from data acquisition to user management. The modules include: 1) an Imagery Retrieval Module to automatically download Landsat-8 Operational Land Imagery (OLI) from the United States Geological Survey (USGS), 2) a Processing Module for automatic detection of Sargassum in the OLI imagery, and subsequent mapping of theses patches in the HYCOM grid, producing maps that show Sargassum clusters; 3) a Forecasting engine fed by the HYbrid Coordinate Ocean Model (HYCOM) model currents and winds from weather buoys; and 4) a mobile phone optimized geospatial user interface. The user can view the last known position of Sargassum clusters, trajectory and location projections for the next 24, 72 and 168 hrs. Users can also subscribe to alerts generated for particular areas. Currently, the SEAS web app produces advisories for Texas beaches. The forecasted Sargassum landing locations are validated by reports from Texas beach managers. However, the SEAS web app was designed to easily expand to other areas, and future plans call for extending the SEAS web app to Mexico and the Caribbean islands. The SEAS web app development is led by NASA, with participation by ASRC Federal/Computer Science Corporation, and the Naval Research Laboratory, all at Stennis Space Center, and Texas A&M University at Galveston.

  18. Ionization detection system for aerosols

    DOEpatents

    Jacobs, Martin E.

    1977-01-01

    This invention relates to an improved smoke-detection system of the ionization-chamber type. In the preferred embodiment, the system utilizes a conventional detector head comprising a measuring ionization chamber, a reference ionization chamber, and a normally non-conductive gas triode for discharging when a threshold concentration of airborne particulates is present in the measuring chamber. The improved system utilizes a measuring ionization chamber which is modified to minimize false alarms and reductions in sensitivity resulting from changes in ambient temperature. In the preferred form of the modification, an annular radiation shield is mounted about the usual radiation source provided to effect ionization in the measuring chamber. The shield is supported by a bimetallic strip which flexes in response to changes in ambient temperature, moving the shield relative to the source so as to vary the radiative area of the source in a manner offsetting temperature-induced variations in the sensitivity of the chamber.

  19. Microcontroller based driver alertness detection systems to detect drowsiness

    NASA Astrophysics Data System (ADS)

    Adenin, Hasibah; Zahari, Rahimi; Lim, Tiong Hoo

    2018-04-01

    The advancement of embedded system for detecting and preventing drowsiness in a vehicle is a major challenge for road traffic accident systems. To prevent drowsiness while driving, it is necessary to have an alert system that can detect a decline in driver concentration and send a signal to the driver. Studies have shown that traffc accidents usually occur when the driver is distracted while driving. In this paper, we have reviewed a number of detection systems to monitor the concentration of a car driver and propose a portable Driver Alertness Detection System (DADS) to determine the level of concentration of the driver based on pixelated coloration detection technique using facial recognition. A portable camera will be placed at the front visor to capture facial expression and the eye activities. We evaluate DADS using 26 participants and have achieved 100% detection rate with good lighting condition and a low detection rate at night.

  20. Early Oscillation Detection Technique for Hybrid DC/DC Converters

    NASA Technical Reports Server (NTRS)

    Wang, Bright L.

    2011-01-01

    Oscillation or instability is a situation that must be avoided for reliable hybrid DC/DC converters. A real-time electronics measurement technique was developed to detect catastrophic oscillations at early stages for hybrid DC/DC converters. It is capable of identifying low-level oscillation and determining the degree of the oscillation at a unique frequency for every individual model of the converters without disturbing their normal operations. This technique is specially developed for space-used hybrid DC/DC converters, but it is also suitable for most of commercial and military switching-mode power supplies. This is a weak-electronic-signal detection technique to detect hybrid DC/DC converter oscillation presented as a specific noise signal at power input pins. It is based on principles of feedback control loop oscillation and RF signal modulations, and is realized by using signal power spectral analysis. On the power spectrum, a channel power amplitude at characteristic frequency (CPcf) and a channel power amplitude at switching frequency (CPsw) are chosen as oscillation level indicators. If the converter is stable, the CPcf is a very small pulse and the CPsw is a larger, clear, single pulse. At early stage of oscillation, the CPcf increases to a certain level and the CPsw shows a small pair of sideband pulses around it. If the converter oscillates, the CPcf reaches to a higher level and the CPsw shows more high-level sideband pulses. A comprehensive stability index (CSI) is adopted as a quantitative measure to accurately assign a degree of stability to a specific DC/DC converter. The CSI is a ratio of normal and abnormal power spectral density, and can be calculated using specified and measured CPcf and CPsw data. The novel and unique feature of this technique is the use of power channel amplitudes at characteristic frequency and switching frequency to evaluate stability and identify oscillations at an early stage without interfering with a DC/DC converter s

  1. The early detection of antral malignancy in the postmaxillectomy patient

    SciT

    Som, P.M.; Shugar, J.M.; Biller, H.F.

    1982-05-01

    A protocol was developed for the radiographic evaluation of the postmaxillectomy patient that called for a six- to eight-week postoperative, baseline computed tomography (CT) scan, followed by CT scans at four- to six-month intervals for at least three years. This protocol allowed for an early, more complete assessment of clinically discovered recurrences and the detection of clinically occult recurrences in three out of 18 patients who followed the protocol. The CT appearance of the normal partial and total maxillectomy is discussed, as well as the focal nodular soft-tissue findings suggestive of recurrent disease.

  2. Printed strain sensors for early damage detection in engineering structures

    NASA Astrophysics Data System (ADS)

    Zymelka, Daniel; Yamashita, Takahiro; Takamatsu, Seiichi; Itoh, Toshihiro; Kobayashi, Takeshi

    2018-05-01

    In this paper, we demonstrate the analysis of strain measurements recorded using a screen-printed sensors array bonded to a metal plate and subjected to high strains. The analysis was intended to evaluate the capabilities of the printed strain sensors to detect abnormal strain distribution before actual defects (cracks) in the analyzed structures appear. The results demonstrate that the developed device can accurately localize the enhanced strains at the very early stage of crack formation. The promising performance and low fabrication cost confirm the potential suitability of the printed strain sensors for applications within the framework of structural health monitoring (SHM).

  3. Method for early detection of cooling-loss events

    DOEpatents

    Bermudez, Sergio A.; Hamann, Hendrik; Marianno, Fernando J.

    2015-06-30

    A method of detecting cooling-loss event early is provided. The method includes defining a relative humidity limit and change threshold for a given space, measuring relative humidity in the given space, determining, with a processing unit, whether the measured relative humidity is within the defined relative humidity limit, generating a warning in an event the measured relative humidity is outside the defined relative humidity limit and determining whether a change in the measured relative humidity is less than the defined change threshold for the given space and generating an alarm in an event the change is greater than the defined change threshold.

  4. Method for early detection of cooling-loss events

    DOEpatents

    Bermudez, Sergio A.; Hamann, Hendrik F.; Marianno, Fernando J.

    2015-12-22

    A method of detecting cooling-loss event early is provided. The method includes defining a relative humidity limit and change threshold for a given space, measuring relative humidity in the given space, determining, with a processing unit, whether the measured relative humidity is within the defined relative humidity limit, generating a warning in an event the measured relative humidity is outside the defined relative humidity limit and determining whether a change in the measured relative humidity is less than the defined change threshold for the given space and generating an alarm in an event the change is greater than the defined change threshold.

  5. Pulsed helium ionization detection system

    DOEpatents

    Ramsey, R.S.; Todd, R.A.

    1985-04-09

    A helium ionization detection system is provided which produces stable operation of a conventional helium ionization detector while providing improved sensitivity and linearity. Stability is improved by applying pulsed dc supply voltage across the ionization detector, thereby modifying the sampling of the detectors output current. A unique pulse generator is used to supply pulsed dc to the detector which has variable width and interval adjust features that allows up to 500 V to be applied in pulse widths ranging from about 150 nsec to about dc conditions.

  6. Pulsed helium ionization detection system

    DOEpatents

    Ramsey, Roswitha S.; Todd, Richard A.

    1987-01-01

    A helium ionization detection system is provided which produces stable operation of a conventional helium ionization detector while providing improved sensitivity and linearity. Stability is improved by applying pulsed dc supply voltage across the ionization detector, thereby modifying the sampling of the detectors output current. A unique pulse generator is used to supply pulsed dc to the detector which has variable width and interval adjust features that allows up to 500 V to be applied in pulse widths ranging from about 150 nsec to about dc conditions.

  7. Infrared trace element detection system

    DOEpatents

    Bien, Fritz; Bernstein, Lawrence S.; Matthew, Michael W.

    1988-01-01

    An infrared trace element detection system including an optical cell into which the sample fluid to be examined is introduced and removed. Also introduced into the optical cell is a sample beam of infrared radiation in a first wavelength band which is significantly absorbed by the trace element and a second wavelength band which is not significantly absorbed by the trace element for passage through the optical cell through the sample fluid. The output intensities of the sample beam of radiation are selectively detected in the first and second wavelength bands. The intensities of a reference beam of the radiation are similarly detected in the first and second wavelength bands. The sensed output intensity of the sample beam in one of the first and second wavelength bands is normalized with respect to the other and similarly, the intensity of the reference beam of radiation in one of the first and second wavelength bands is normalized with respect to the other. The normalized sample beam intensity and normalized reference beam intensity are then compared to provide a signal from which the amount of trace element in the sample fluid can be determined.

  8. Infrared trace element detection system

    DOEpatents

    Bien, F.; Bernstein, L.S.; Matthew, M.W.

    1988-11-15

    An infrared trace element detection system includes an optical cell into which the sample fluid to be examined is introduced and removed. Also introduced into the optical cell is a sample beam of infrared radiation in a first wavelength band which is significantly absorbed by the trace element and a second wavelength band which is not significantly absorbed by the trace element for passage through the optical cell through the sample fluid. The output intensities of the sample beam of radiation are selectively detected in the first and second wavelength bands. The intensities of a reference beam of the radiation are similarly detected in the first and second wavelength bands. The sensed output intensity of the sample beam in one of the first and second wavelength bands is normalized with respect to the other and similarly, the intensity of the reference beam of radiation in one of the first and second wavelength bands is normalized with respect to the other. The normalized sample beam intensity and normalized reference beam intensity are then compared to provide a signal from which the amount of trace element in the sample fluid can be determined. 11 figs.

  9. Computer-assisted detection (CAD) methodology for early detection of response to pharmaceutical therapy in tuberculosis patients

    NASA Astrophysics Data System (ADS)

    Lieberman, Robert; Kwong, Heston; Liu, Brent; Huang, H. K.

    2009-02-01

    The chest x-ray radiological features of tuberculosis patients are well documented, and the radiological features that change in response to successful pharmaceutical therapy can be followed with longitudinal studies over time. The patients can also be classified as either responsive or resistant to pharmaceutical therapy based on clinical improvement. We have retrospectively collected time series chest x-ray images of 200 patients diagnosed with tuberculosis receiving the standard pharmaceutical treatment. Computer algorithms can be created to utilize image texture features to assess the temporal changes in the chest x-rays of the tuberculosis patients. This methodology provides a framework for a computer-assisted detection (CAD) system that may provide physicians with the ability to detect poor treatment response earlier in pharmaceutical therapy. Early detection allows physicians to respond with more timely treatment alternatives and improved outcomes. Such a system has the potential to increase treatment efficacy for millions of patients each year.

  10. Future Directions for the Early Detection of Colorectal Cancer Recurrence

    PubMed Central

    Walker, Avery S.; Johnson, Eric K.; Maykel, Justin A.; Stojadinovic, Alex; Nissan, Aviram; Brucher, Bjorn; Champagne, Bradley J.; Steele, Scott R.

    2014-01-01

    Surgical resection remains a mainstay of treatment and is highly effective for localized colorectal cancer. However, ~30-40% of patients develop recurrence following surgery and 40-50% of recurrences are apparent within the first few years after initial surgical resection. Several variables factor into the ultimate outcome of these patients, including the extent of disease, tumor biology, and patient co-morbidities. Additionally, the time from initial treatment to the development of recurrence is strongly associated with overall survival, particularly in patients who recur within one year of their surgical resection. Current post-resection surveillance strategies involve physical examination, laboratory, endoscopic and imaging studies utilizing various high and low-intensity protocols. Ultimately, the goal is to detect recurrence as early as possible, and ideally in the asymptomatic localized phase, to allow initiation of treatment that may still result in cure. While current strategies have been effective, several efforts are evolving to improve our ability to identify recurrent disease at its earliest phase. Our aim with this article is to briefly review the options available and, more importantly, examine emerging and future options to assist in the early detection of colon and rectal cancer recurrence. PMID:24790655

  11. Explosives detection system and method

    DOEpatents

    Reber, Edward L.; Jewell, James K.; Rohde, Kenneth W.; Seabury, Edward H.; Blackwood, Larry G.; Edwards, Andrew J.; Derr, Kurt W.

    2007-12-11

    A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

  12. Comparison of Laser Scanning Diagnostic Devices for Early Glaucoma Detection.

    PubMed

    Schulze, Andreas; Lamparter, Julia; Pfeiffer, Norbert; Berisha, Fatmire; Schmidtmann, Irene; Hoffmann, Esther M

    2015-08-01

    To compare the diagnostic accuracy and to evaluate the correlation of optic nerve head and retinal nerve fiber layer thickness values between Fourier-Domain optical coherence tomography (FD-OCT), confocal scanning laser ophthalmoscopy (CSLO), and scanning laser polarimetry (SLP) for early glaucoma detection. Ninety-three patients with early open-angle glaucoma, 58 patients with ocular hypertension, and 60 healthy control subjects were included in this observational, cross-sectional study. All study participants underwent FD-OCT (RTVue-100), CSLO (HRT3), and SLP (GDx VCC) imaging of the optic nerve head and the retinal nerve fiber layer. Area under the receiver operating characteristic curves (AUROC) and Bland-Altman analysis were performed. The parameters with the highest diagnostic accuracy were found for FD-OCT cup-to-disc ratio (AUROC=0.841), for SLP NFI (AUROC=0.835), and for CSLO cup-to-disc ratio (AUROC=0.789). Diagnostic accuracy of the best CSLO and SLP parameter was similar (P=0.259). There was a small statistically significant difference between the best CSLO and FD-OCT parameters for differentiating between glaucoma and healthy eyes (P=0.047). FD-OCT and SLP have a similarly good diagnostic ability to distinguish between early glaucoma and healthy subjects. The diagnostic accuracy of CSLO was comparable with SLP and marginally lower compared with FD-OCT.

  13. Detection of early changes in lung cell cytology by flow-systems analysis techniques. Progress report, October 1, 1976--June 30, 1977. [Damage induced by exposure to toxic agents associated with production of synthetic fuels from oil shale and coal

    SciT

    Steinkamp, J.A.; Hansen, K.M.; Wilson, J.S.

    1977-07-01

    This report summarizes results of continuing experiments to develop cytological and biochemical indicators for estimating damage to respiratory tract cells in animals exposed to toxic agents associated with production of synthetic fuels from oil shale and coal, the specific goal being the application of advanced flow-systems technologies to the detection of early atypical cellular changes in lung epithelium. The objectives of the program during the past 6 months were: to develop standard methods for lavaging lungs of several rodent species (hamster, rat, and mouse) to increase cell yield; initiate oil shale exposures in hamsters and rats; study the effects ofmore » macrophage mobility in the presence of oil shale; and determine the effects of different fixatives on lung cell morphology using electron microscopy. To develop standard methods for lavaging the respiratory tract of test animals, experiments were devised to increase cell yield with minimal debris and blood. Proteolytic enzymes such as trypsin were also tested but produced excessive amounts of fibrinated blood. Experimental animals were exposed to raw and spent oil shale particulates to determine if changes in lung cell differential counts and/or atypical cellular changes were noted. Since the multiparameter cell separator system was inoperative during this reporting period due to major modifications, including the addition of an uv krypton laser, emphasis was primarily on cytological techniques. As the flow-systems instrumentation becomes fully operational during the next month, automated analysis of respiratory tract cells and measurement of physical and biochemical properties as a function of exposure to toxic agents will continue.« less

  14. Capillary Electrophoresis - Optical Detection Systems

    SciT

    Sepaniak, M. J.

    2001-08-06

    Molecular recognition systems are developed via molecular modeling and synthesis to enhance separation performance in capillary electrophoresis and optical detection methods for capillary electrophoresis. The underpinning theme of our work is the rational design and development of molecular recognition systems in chemical separations and analysis. There have been, however, some subtle and exciting shifts in our research paradigm during this period. Specifically, we have moved from mostly separations research to a good balance between separations and spectroscopic detection for separations. This shift is based on our perception that the pressing research challenges and needs in capillary electrophoresis and electrokinetic chromatographymore » relate to the persistent detection and flow rate reproducibility limitations of these techniques (see page 1 of the accompanying Renewal Application for further discussion). In most of our work molecular recognition reagents are employed to provide selectivity and enhance performance. Also, an emerging trend is the use of these reagents with specially-prepared nano-scale materials. Although not part of our DOE BES-supported work, the modeling and synthesis of new receptors has indirectly supported the development of novel microcantilevers-based MEMS for the sensing of vapor and liquid phase analytes. This fortuitous overlap is briefly covered in this report. Several of the more significant publications that have resulted from our work are appended. To facilitate brevity we refer to these publications liberally in this progress report. Reference is also made to very recent work in the Background and Preliminary Studies Section of the Renewal Application.« less

  15. Environmental DNA as a new method for early detection of New Zealand mudsnails (Potamopyrgus antipodarum)

    Goldberg, Caren S.; Sepulveda, Adam; Ray, Andrew; Baumgardt, Jeremy A.; Waits, Lisette P.

    2013-01-01

    Early detection of aquatic invasive species is a critical task for management of aquatic ecosystems. This task is hindered by the difficulty and cost of surveying aquatic systems thoroughly. The New Zealand mudsnail (Potamopyrgus antipodarum) is a small, invasive parthenogenic mollusk that can reach very high population densities and severely affects ecosystem functioning. To assist in the early detection of this invasive species, we developed and validated a highly sensitive environmental deoxyribonucleic acid (eDNA) assay. We used a dose–response laboratory experiment to investigate the relationship between New Zealand mudsnail density and eDNA detected through time. We documented that as few as 1 individual in 1.5 L of water for 2 d could be detected with this method, and that eDNA from this species may remain detectable for 21 to 44 d after mudsnail removal. We used the eDNA method to confirm the presence of New Zealand mudsnail eDNA at densities as low as 11 to 144 snails/m2 in a eutrophic 5th-order river. Combined, these results demonstrate the high potential for eDNA surveys to assist with early detection of a widely distributed invasive aquatic invertebrate.

  16. [Early detection on the onset of scarlet fever epidemics in Beijing, using the Cumulative Sum].

    PubMed

    Li, Jing; Yang, Peng; Wu, Shuang-sheng; Wang, Xiao-li; Liu, Shuang; Wang, Quan-yi

    2013-05-01

    Based on data related to scarlet fever which was collected from the Disease Surveillance Information Reporting System in Beijing from 2005 to 2011, to explore the efficiency of Cumulative Sum (CUSUM) in detecting the onset of scarlet fever epidemics. Models as C1-MILD (C1), C2-MEDIUM (C2) and C3-ULTRA (C3) were used. Tools for evaluation as Youden's index and detection time were calculated to optimize the parameters and optimal model. Data on 2011 scarlet fever surveillance was used to verify the efficacy of these models. C1 (k = 0.5, H = 2σ), C2 (k = 0.7, H = 2σ), C3 (k = 1.1, H = 2σ) appeared to be the optimal parameters among these models. Youden's index of C1 was 83.0% and detection time being 0.64 weeks, Youden's index of C2 was 85.4% and detection time being 1.27 weeks, Youden's index of C1 was 85.1% and detection time being 1.36 weeks. Among the three early warning detection models, C1 had the highest efficacy. Three models all triggered the signals within 4 weeks after the onset of scarlet fever epidemics. The early warning detection model of CUSUM could be used to detect the onset of scarlet fever epidemics, with good efficacy.

  17. Surface engineered biosensors for the early detection of cancer

    NASA Astrophysics Data System (ADS)

    Islam, Muhymin

    Cancer commences in the building block of human body which is cells and in most of the cases remains silent at early stage. Diseases are only expressed at molecular and cellular level at primary stages. Recognition of diseases at this micro and nano level might reduce the mortality rate of cancer significantly. This research work aimed to introduce novel electronic biosensors for for identification of cancer at cellular level. The dissertation study focuses on 1) Label-Free Isolation of Metastatic Tumor Cells Using Filter Based Microfluidic device; 2) Nanotextured Polymer Substrates for Enhanced Cancer Cell Isolation and Cell Growth; 3) Nanotextured Microfluidic Channel for Electrical Profiling and Detection of Tumor Cells from Blood; and 4) Single Biochip for the Detection of Tumor Cells by Electrical Profile and Surface Immobilized Aptamer. Standard silicon processing techniques were followed to fabricate all of the biosensors. Nantoextruing and surface functionalizon were also incorporated to elevate the efficiency of the devices. The first approach aimed to detect cancer cells from blood based on their mechanophysical properties. Cancer cells are larger than blood cells but highly elastic in nature. These cells can squeeze through small microchannels much smaller than their size. The cross sectional area of the microchannels was optimized to isolate tumor cells from blood. Nanotextured polymer substrates, a platform inspired from the natural basement membrane was used to enhance the isolation and growth of tumor cells. Micro reactive ion etching was performed to have better control on features of nantoxtured surfaces and did not require any template. Next, electrical measurement of ionic current was performed across single microchannel to detect tumor cells from blood. Later, nanotexturing enhanced the efficiency of the device by selectively altering the translocation profile of cancer cells. Eventually aptamer functionalized nanotextured polymer surface was

  18. Detection of early warning signals of forest mortality in California

    NASA Astrophysics Data System (ADS)

    Liu, Y.; Kumar, M.; Katul, G. G.; Porporato, A. M.

    2017-12-01

    Massive forest mortality was observed in California during the most recent drought. Owing to complex interactions of physiological mechanisms under stress, prediction of climate-induced forest mortality using dynamic global vegetation models remains fraught with uncertainty. Given that forest ecosystems approaching mortality tend to exhibit reduction in resilience, we evaluate the time-varying resilience from time series of satellite images to detect early warning signals (EWSs) of mortality. Four metrics of EWSs are used: (1) low greenness, (2) high empirical autocorrelation of greenness, (3) high autocorrelation inferred using a Bayesian dynamic linear model considering the influence of seasonality and climate conditions, and (4) low recovery rate inferred from the drift term in the Langevin equation describing stochastic dynamics. Spatial accuracy and lead-time of these EWSs are evaluated by comparing the EWSs against observed mortality from aerial surveys conducted by the US Forest Service. Our results show that most forested areas in California that underwent mortality exhibit a EWS with a lead time of three months to two years ahead of observed mortality. Notably, EWS is also detected in some areas without mortality, suggesting reduced resilience during drought. Furthermore, the influence of the previous drought (2007-2009) may have propagated into the recent drought (2012-2016) through reduced resilience, hence contributing to the massive forest mortality observed recently. Methodologies developed in this study for detection of EWS will improve the near-term predictability of forest mortality, thus providing crucial information for forest and water resource management.

  19. A Portable Infrasonic Detection System

    NASA Technical Reports Server (NTRS)

    Shams, Qamar A.; Burkett, Cecil G.; Zuckerwar, Allan J.; Lawrenson, Christopher C.; Masterman, Michael

    2008-01-01

    During last couple of years, NASA Langley has designed and developed a portable infrasonic detection system which can be used to make useful infrasound measurements at a location where it was not possible previously. The system comprises an electret condenser microphone, having a 3-inch membrane diameter, and a small, compact windscreen. Electret-based technology offers the lowest possible background noise, because Johnson noise generated in the supporting electronics (preamplifier) is minimized. The microphone features a high membrane compliance with a large backchamber volume, a prepolarized backplane and a high impedance preamplifier located inside the backchamber. The windscreen, based on the high transmission coefficient of infrasound through matter, is made of a material having a low acoustic impedance and sufficiently thick wall to insure structural stability. Close-cell polyurethane foam has been found to serve the purpose well. In the proposed test, test parameters will be sensitivity, background noise, signal fidelity (harmonic distortion), and temporal stability. The design and results of the compact system, based upon laboratory and field experiments, will be presented.

  20. Planetary system detection by POINTS

    NASA Technical Reports Server (NTRS)

    Reasenberg, Robert D.

    1993-01-01

    The final report and semiannual reports 1, 2, and 3 in response to the study of 'Planetary System Detection by POINTS' is presented. The grant covered the period from 15 Jun. 1988 through 31 Dec. 1989. The work during that period comprised the further development and refinement of the POINTS concept. The status of the POINTS development at the end of the Grant period was described by Reasenberg in a paper given at the JPL Workshop on Space Interferometry, 12-13 Mar. 1990, and distributed as CfA Preprint 3138. That paper, 'POINTS: a Small Astrometric Interferometer,' follows as Appendix-A. Our proposal P2276-7-09, dated July 1990, included a more detailed description of the state of the development of POINTS at the end of the tenure of Grant NAGW-1355. That proposal, which resulted in Grant NAGW-2497, is included by reference.

  1. Recursive SVM biomarker selection for early detection of breast cancer in peripheral blood.

    PubMed

    Zhang, Fan; Kaufman, Howard L; Deng, Youping; Drabier, Renee

    2013-01-01

    Curve) in the testing data set from 0.5826 to 0.7879. Further pathway analysis showed that the biomarkers are associated with Signaling, Hemostasis, Hormones, and Immune System, which are consistent with previous findings. Our prediction model can serve as a general model for biomarker discovery in early detection of other cancers. In the future, Polymerase Chain Reaction (PCR) is planned for validation of the ability of these potential biomarkers for early detection of breast cancer.

  2. Early warning system for Douglas-fir tussock moth outbreaks in the Western United States.

    Gary E. Daterman; John M. Wenz; Katharine A. Sheehan

    2004-01-01

    The Early Warning System is a pheromone-based trapping system used to detect outbreaks of Douglas-fir tussock moth (DFTM, Orgyia pseudotsugata) in the western United States. Millions of acres are susceptible to DFTM defoliation, but Early Warning System monitoring focuses attention only on the relatively limited areas where outbreaks may be...

  3. Cancer screening and early detection in the 21st century

    PubMed Central

    Murphy, Jeanne

    2017-01-01

    Objective To review the trends in and principles of cancer screening and early detection. Data Sources Journal articles, United States Preventive Services Task Force (U SPSTF) publications, professional organization position statements, evidence-based summaries Conclusion Cancer screening has contributed to decreasing the morbidity and mortality of cancer. Efforts to improve the selection of candidates for cancer screening, to understand the biological basis of carcinogenesis, and the development of new technologies for cancer screening will allow for improvements in the cancer screening over time. Implications for Nursing Practice Nurses are well-positioned to lead the implementation of cancer screening recommendations in the 21st Century through their practice, research, educational efforts and advocacy. PMID:28343835

  4. Early detection of psychosis: finding those at clinical high risk.

    PubMed

    Addington, Jean; Epstein, Irvin; Reynolds, Andrea; Furimsky, Ivana; Rudy, Laura; Mancini, Barbara; McMillan, Simone; Kirsopp, Diane; Zipursky, Robert B

    2008-08-01

    In early detection work, recruiting individuals who meet the prodromal criteria is difficult. The aim of this paper was to describe the development of a research clinic for individuals who appear to be at risk of developing a psychosis and the process for educating the community and obtaining referrals. The outcome of all referrals to the clinic over a 4-year period was examined. Following an ongoing education campaign that was over inclusive in order to aid recruitment, approximately 27% of all referrals met the criteria for being at clinical high risk of psychosis. We are seeing only a small proportion of those in the community who eventually go on to develop a psychotic illness. This raises two important issues, namely how to remedy the situation, and second, the impact of this on current research in terms of sampling bias and generalizability of research findings. © 2008 The Authors. Journal compilation © 2008 Blackwell Publishing Asia Pty Ltd.

  5. Evaluation and early detection of problematic Internet use in adolescents.

    PubMed

    Gómez Salgado, Patricia; Rial Boubeta, Antonio; Braña Tobío, Teresa; Varela Mallou, Jesús; Barreiro Couto, Carmen

    2014-01-01

    Problematic Internet use in adolescents has become an issue of concern for a growing number of researchers and institutions over the past years. Behavioural problems, social isolation, school failure and family problems are some of the consequences of psychological and behavioural impact on teenagers. Taking into account the interest that this issue has generated at many levels, the aim of this paper is to develop a screening tool for early detection of problematic Internet use in teenagers. A survey of Compulsory Secondary School students from Galicia involving a total of 2,339 individuals was carried out. The results obtained allow (1) gauging the magnitude of the problem, establishing the risk levels among the adolescents, and (2) presenting a new, simple and short screening instrument. The present scale has sufficient theoretical and empirical support, including good psychometric properties (a = .83; specificity = .81; sensitivity = .80; ROC curve = .90), making it an interesting applied tool.

  6. A deep-learning based automatic pulmonary nodule detection system

    NASA Astrophysics Data System (ADS)

    Zhao, Yiyuan; Zhao, Liang; Yan, Zhennan; Wolf, Matthias; Zhan, Yiqiang

    2018-02-01

    Lung cancer is the deadliest cancer worldwide. Early detection of lung cancer is a promising way to lower the risk of dying. Accurate pulmonary nodule detection in computed tomography (CT) images is crucial for early diagnosis of lung cancer. The development of computer-aided detection (CAD) system of pulmonary nodules contributes to making the CT analysis more accurate and with more efficiency. Recent studies from other groups have been focusing on lung cancer diagnosis CAD system by detecting medium to large nodules. However, to fully investigate the relevance between nodule features and cancer diagnosis, a CAD that is capable of detecting nodules with all sizes is needed. In this paper, we present a deep-learning based automatic all size pulmonary nodule detection system by cascading two artificial neural networks. We firstly use a U-net like 3D network to generate nodule candidates from CT images. Then, we use another 3D neural network to refine the locations of the nodule candidates generated from the previous subsystem. With the second sub-system, we bring the nodule candidates closer to the center of the ground truth nodule locations. We evaluate our system on a public CT dataset provided by the Lung Nodule Analysis (LUNA) 2016 grand challenge. The performance on the testing dataset shows that our system achieves 90% sensitivity with an average of 4 false positives per scan. This indicates that our system can be an aid for automatic nodule detection, which is beneficial for lung cancer diagnosis.

  7. First step toward translation of thermophotonic lock-in imaging to dentistry as an early caries detection technology

    NASA Astrophysics Data System (ADS)

    Ojaghi, Ashkan; Parkhimchyk, Artur; Tabatabaei, Nima

    2016-09-01

    Early detection of the most prevalent oral disease worldwide, i.e., dental caries, still remains as one of the major challenges in dentistry. The current dental standard of care relies on caries detection methods, such as visual inspection and x-ray radiography, which lack the sufficient specificity and sensitivity to detect caries at early stages of formation when they can be healed. We report on the feasibility of early caries detection in a clinically and commercially viable thermophotonic imaging system. The system incorporates intensity-modulated laser light along with a low-cost long-wavelength infrared (LWIR; 8 to 14 μm) camera, providing diagnostic contrast based on the enhanced light absorption of early caries. The LWIR camera is highly suitable for integration into clinical platforms because of its low weight and cost. In addition, through theoretical modeling, we show that LWIR detection enhances the diagnostic contrast due to the minimal LWIR transmittance of enamel and suppression of the masking effect of the direct thermal Planck emission. Diagnostic performance of the system and its detection threshold are experimentally evaluated by monitoring the inception and progression of artificially induced occlusal and smooth surface caries. The results are suggestive of the suitability of the developed LWIR system for detecting early dental caries.

  8. Early detection of anastomotic leakage after elective low anterior resection.

    PubMed

    Fouda, Elyamani; El Nakeeb, Ayman; Magdy, Alaa; Hammad, Enas A; Othman, Gamal; Farid, Mohamed

    2011-01-01

    Colorectal anastomotic leakage is a serious complication leading to major postoperative morbidity and mortality. In the present study, we investigated the early detection of anastomotic leakage before its clinical presentation. Fifty-six patients with rectal cancer were included prospectively in this study. All patients underwent elective low anterior resection. Peritoneal samples were collected from the abdominal drains at the first, third, and fifth days postoperatively for bacteriological study (quantitative cultures for both aerobes and anaerobes) and cytokines (IL-6, IL-10, TNF) measurement. Patients were divided into two groups: those without symptomatic or clinical evidence of anastomotic leakage (AL; group 1) and those with clinical evidence of AL (group 2). Study variables included hospital stay, wound infection, operative time, blood loss, height of anastomosis, intraperitoneal cytokines, and microbiological study of peritoneal fluid. Clinically evident AL occurred in eight patients (14.3%) and diagnosed postoperatively on median day 6. Intraperitoneal bacterial colonization and cytokine levels were significantly higher in patients with clinical evidence of AL. Wound infection was significantly higher in anastomotic leakage group. The hospital stay for the patients with anastomotic leakage was significantly longer than those without AL (14 ± 1.41 vs. 5.43 ± 0.89 days). A significant difference among two groups was observed regarding operative time, blood loss, blood transfusion, and height of the anastomosis. The peritoneal cytokines levels and intraperitoneal bacterial colonization might be an additional diagnostic tool that can support the decision making of surgeons for early detection of anastomotic leak in colorectal surgery.

  9. Early detection and treatment of postnatal depression in primary care.

    PubMed

    Davies, Bronwen R; Howells, Sarah; Jenkins, Meryl

    2003-11-01

    Postnatal depression has a relatively high incidence and gives rise to considerable morbidity. There is sound evidence supporting the use of the Edinburgh Postnatal Depression Scale as a screening tool for possible postnatal depression. This paper reports on a project developed by two health visitors and a community mental health nurse working in the United Kingdom. The aim of the project was to improve the early detection and treatment of postnatal depression in the population of the general practice to which they were attached. The health visitors screened for postnatal depression in the course of routine visits on four occasions during the first postpartum year. Women identified as likely to be suffering from postnatal depression were offered 'listening visits' as a first-line intervention, with referral on to the general practitioner and/or community mental health nurse if indicated. Data collected over 3 years showed that the project succeeded in its aim of enhancing early detection and treatment of postnatal depression. These findings replicate those of other studies. The data also showed that a substantial number of women were identified for the first time as likely to be suffering from postnatal depression at 12 months postpartum. Women screened for the first time at 12 months were at greater risk than those who had been screened earlier than this. Health visitors should screen for postnatal depression throughout the period of their contact with mothers, not solely in the immediate postnatal period. It is particularly important to screen women who, for whatever reason, were not screened when their child was younger. The knowledge and skills needed to use the Edinburgh Postnatal Depression Scale and provide first-line intervention and onward referral can be developed at practitioner level through close collaborative working.

  10. DESI-Detection of early-season invasives (software-installation manual and user's guide version 1.0)

    Kokaly, Raymond F.

    2011-01-01

    This report describes a software system for detecting early-season invasive plant species, such as cheatgrass. The report includes instructions for installing the software and serves as a user's guide in processing Landsat satellite remote sensing data to map the distributions of cheatgrass and other early-season invasive plants. The software was developed for application to the semi-arid regions of southern Utah; however, the detection parameters can be altered by the user for application to other areas.

  11. Early Communication System (ECOMM) for ISS

    NASA Technical Reports Server (NTRS)

    Gaylor, Kent; Tu, Kwei

    1999-01-01

    The International Space Station (ISS) Early Communications System (ECOMM) was a Johnson Space Center (JSC) Avionic Systems Division (ASD) in-house developed communication system to provide early communications between the ISS and the Mission Control Center-Houston (MCC-H). This system allows for low rate commands (link rate of 6 kbps) to be transmitted through the Tracking and Data Relay Satellite System (TDRSS) from MCC-H to the ISS using TDRSS's S-band Single Access Forward (SSA/) link service. This system also allows for low rate telemetry (link rate of 20.48 kbps) to be transmitted from ISS to MCC-H through the TDRSS using TDRSS's S-band Single Access Return (SSAR) link service. In addition this system supports a JSC developed Onboard Communications Adapter (OCA) that allows for a two-way data exchange of 128 kbps between MCC-H and the ISS through TDRSS. This OCA data can be digital video/audio (two-way videoconference), and/or file transfers, and/or "white board". The key components of the system, the data formats used by the system to insure compatibility with the future ISS S-Band System, as well as how other vehicles may be able to use this system for their needs are discussed in this paper.

  12. Early detection of AD using cortical thickness measurements

    NASA Astrophysics Data System (ADS)

    Spjuth, M.; Gravesen, F.; Eskildsen, S. F.; Østergaard, L. R.

    2007-03-01

    Alzheimer's disease (AD) is a neurodegenerative disorder that causes cortical atrophy and impaired cognitive functions. The diagnosis is difficult to make and is often made over a longer period of time using a combination of neuropsychological tests, and structural and functional imaging. Due to the impact of early intervention the challenge of distinguishing early AD from normal ageing has received increasing attention. This study uses cortical thickness measurements to characterize the atrophy in nine mild AD patients (mean MMSE-score 23.3 (std: 2.6)) compared to five healthy middle-aged subjects. A fully automated method based on deformable models is used for delineation of the inner and outer boundaries of the cerebral cortex from Magnetic Resonance Images. This allows observer independent high-resolution quantification of the cortical thickness. The cortex analysis facilitates detection of alterations throughout the entire cortical mantle. To perform inter-subject thickness comparison in which the spatial information is retained, a feature-based registration algorithm is developed which uses local cortical curvature, normal vector, and a distance measure. A comparison of the two study groups reveals that the lateral side of the hemispheres shows diffuse thinner areas in the mild AD group but especially the medial side shows a pronounced thinner area which can be explained by early limbic changes in AD. For classification principal component analysis is applied to reduce the high number of thickness measurements (>200,000) into fewer features. All mild AD and healthy middle-aged subjects are classified correctly (sensitivity and specificity 100%).

  13. Rest and exercise echocardiography for early detection of pulmonary hypertension.

    PubMed

    Kusunose, Kenya; Yamada, Hirotsugu

    2016-03-01

    Early detection of pulmonary hypertension (PH) is essential to ensure that patients receive timely and appropriate treatment for this progressive disease. Rest and exercise echocardiography has been used to screen patients in an attempt to identify early stage PH. However, current PH guidelines recommend against exercise tests because of the lack of evidence. We reviewed previous studies to discuss the current standpoint concerning rest and exercise echocardiography in PH. Around 20 exercise echocardiography studies were included to assess the cutoff value for exercise-induced pulmonary hypertension (EIPH). Approximately 40 exercise echocardiography studies were also included to evaluate the pulmonary artery pressure-flow relationship as assessed by the slope of the mean pulmonary artery pressure and cardiac output (ΔmPAP/ΔQ). There were several EIPH and ΔmPAP/ΔQ reference values in individuals with pulmonary vascular disease. We believed that assessing the ΔmPAP/ΔQ makes sense from a physiological standpoint, and the clinical value should be confirmed in future studies. Exercise echocardiography is an appealing alternative in PH. Further studies are needed to assess the prognostic value of the pulmonary artery pressure-flow relationship in high-risk subjects.

  14. Multispectral fundus imaging for early detection of diabetic retinopathy

    NASA Astrophysics Data System (ADS)

    Beach, James M.; Tiedeman, James S.; Hopkins, Mark F.; Sabharwal, Yashvinder S.

    1999-04-01

    Functional imaging of the retina and associated structures may provide information for early assessment of risks of developing retinopathy in diabetic patients. Here we show results of retinal oximetry performed using multi-spectral reflectance imaging techniques to assess hemoglobin (Hb) oxygen saturation (OS) in blood vessels of the inner retina and oxygen utilization at the optic nerve in diabetic patients without retinopathy and early disease during experimental hyperglycemia. Retinal images were obtained through a fundus camera and simultaneously recorded at up to four wavelengths using image-splitting modules coupled to a digital camera. Changes in OS in large retinal vessels, in average OS in disk tissue, and in the reduced state of cytochrome oxidase (CO) at the disk were determined from changes in reflectance associated with the oxidation/reduction states of Hb and CO. Step to high sugar lowered venous oxygen saturation to a degree dependent on disease duration. Moderate increase in sugar produced higher levels of reduced CO in both the disk and surrounding tissue without a detectable change in average tissue OS. Results suggest that regulation of retinal blood supply and oxygen consumption are altered by hyperglycemia and that such functional changes are present before clinical signs of retinopathy.

  15. Early Warning Systems Assure Safe Schools

    ERIC Educational Resources Information Center

    Greenhalgh, John

    1973-01-01

    Fairfield, Connecticut, public schools are protected by an automatic fire detection system covering every area of every building through an electric monitor. An intrusion alarm system that relies primarily on pulsed infra-red beams protects the plant investment. (Author/MF)

  16. On the Design of a Bioacoustic Sensor for the Early Detection of the Red Palm Weevil

    PubMed Central

    Rach, Miguel Martínez; Gomis, Héctor Migallón; Granado, Otoniel López; Malumbres, Manuel Perez; Campoy, Antonio Martí; Martín, Juan José Serrano

    2013-01-01

    During the last two decades Red Palm Weevil (RPW, Rynchophorus Ferrugineus) has become one of the most dangerous threats to palm trees in many parts of the World. Its early detection is difficult, since palm trees do not show visual evidence of infection until it is too late for them to recover. For this reason the development of efficient early detection mechanisms is a critical element of RPW pest management systems. One of the early detection mechanisms proposed in the literature is based on acoustic monitoring, as the activity of RPW larvae inside the palm trunk is audible for human operators under acceptable environmental noise levels (rural areas, night periods, etc.). In this work we propose the design of an autonomous bioacoustic sensor that can be installed in every palm tree under study and is able to analyze the captured audio signal during large periods of time. The results of the audio analysis would be reported wirelessly to a control station, to be subsequently processed and conveniently stored. That control station is to be accessible via the Internet. It is programmed to send warning messages when predefined alarm thresholds are reached, thereby allowing supervisors to check on-line the status and evolution of the palm tree orchards. We have developed a bioacoustic sensor prototype and performed an extensive set of experiments to measure its detection capability, achieving average detection rates over 90%. PMID:23364196

  17. On the design of a bioacoustic sensor for the early detection of the red palm weevil.

    PubMed

    Martínez Rach, Miguel; Migallón Gomis, Héctor; López Granado, Otoniel; Perez Malumbres, Manuel; Martí Campoy, Antonio; Serrano Martín, Juan José

    2013-01-30

    During the last two decades Red Palm Weevil (RPW, Rynchophorus Ferrugineus) has become one of the most dangerous threats to palm trees in many parts of the World. Its early detection is difficult, since palm trees do not show visual evidence of infection until it is too late for them to recover. For this reason the development of efficient early detection mechanisms is a critical element of RPW pest management systems. One of the early detection mechanisms proposed in the literature is based on acoustic monitoring, as the activity of RPW larvae inside the palm trunk is audible for human operators under acceptable environmental noise levels (rural areas, night periods, etc.). In this work we propose the design of an autonomous bioacoustic sensor that can be installed in every palm tree under study and is able to analyze the captured audio signal during large periods of time. The results of the audio analysis would be reported wirelessly to a control station, to be subsequently processed and conveniently stored. That control station is to be accessible via the Internet. It is programmed to send warning messages when predefined alarm thresholds are reached, thereby allowing supervisors to check on-line the status and evolution of the palm tree orchards. We have developed a bioacoustic sensor prototype and performed an extensive set of experiments to measure its detection capability, achieving average detection rates over 90%.

  18. Oral precancerous lesions: Problems of early detection and oral cancer prevention

    NASA Astrophysics Data System (ADS)

    Gileva, Olga S.; Libik, Tatiana V.; Danilov, Konstantin V.

    2016-08-01

    The study presents the results of the research in the structure, local and systemic risk factors, peculiarities of the clinical manifestation, and quality of primary diagnosis of precancerous oral mucosa lesions (OMLs). In the study a wide range of OMLs and high (25.4%) proportion of oral precancerous lesions (OPLs) in their structure was indicated. The high percentage of different diagnostic errors and the lack of oncological awareness of dental practitioners, as well as the sharp necessity of inclusion of precancer/cancer early detection techniques into their daily practice were noted. The effectiveness of chemilumenescence system of early OPLs and oral cancer detection was demonstrated, the prospects of infrared thermography as a diagnostic tool were also discussed.

  19. [Early detection of occupational skin diseases in sewer workers].

    PubMed

    Lang, V; Lauffer, F; Fincan, Y; Biedermann, T; Zink, A

    2018-04-25

    Skin diseases affect 30-70% of the world population, and globally, skin cancer rates are continuously increasing. In this respect, prevention programs and early detection of skin diseases are of particular importance. To screen sewer workers for skin diseases with regard to their work-related risk. Employees of the municipal utilities in Munich (Münchner Stadtentwässerung) underwent a whole-body examination of the skin, conducted by two dermatologists. In addition, all employees completed a paper-based questionnaire on risk behavior and preventive measures. We examined 81 employees (79 men, 2 women, mean age 45.7 ± 9.5 years). Skin lesions in need of treatment were found in 30.9% (n = 25): the most frequent diagnosis was mycosis pedis (16.1%). In addition, one employee was diagnosed with basal cell carcinoma and two with actinic keratoses. According to the questionnaire, 43.5% of the employees had undergone a physician-led skin cancer screening in the past, whereas sun-protection practices were rarely applied. According to our findings, employee skin cancer screening seems to be beneficial for the detection of work-related skin diseases and is associated with a high participation rate. Furthermore, the study suggests that sewer workers have a high rate of mycosis pedis, possibly a work-related effect.

  20. Indocyanine green detects sentinel lymph nodes in early breast cancer.

    PubMed

    Liu, Jun; Huang, Linping; Wang, Ning; Chen, Ping

    2017-04-01

    Objective To explore the clinical value of indocyanine green (ICG) for the fluorescence-guided detection of sentinel lymph nodes (SLNs) during sentinel lymph node biopsy (SLNB) in patients with early breast cancer. Methods This retrospective study included female patients with breast cancer. Patients were administered methylene blue and ICG using standard techniques. All SLNs that were collected during surgery were submitted for pathological examination. SLNs were defined as those that were either fluorescent, blue, fluorescent and blue or palpably suspicious. Surgical complications, axillary recurrence, distant metastasis and overall survival rates were observed postoperatively. Results A total of 60 patients were enrolled in the study. The fluorescence detection rate of SLNs was 100% ( n = 177), with a mean of 2.95 SLNs per patient. The methylene blue staining rate was 88.3% ( n = 106), with a mean of 1.77 SLNs per patient. Pathological assessment of intraoperative frozen specimens revealed SLN metastases in 10 patients, who immediately underwent axillary lymph node dissection. No patient had axillary recurrence or distant metastases, with a survival rate of 100%. Patients who underwent SLNB showed good appearance in the axillary wound, with no limited shoulder joint abduction and upper limb oedema. Conclusion Fluorescence-guided SLNB has several advantages and is suitable for clinical application.

  1. Early and Real-Time Detection of Seasonal Influenza Onset

    PubMed Central

    Marques-Pita, Manuel

    2017-01-01

    Every year, influenza epidemics affect millions of people and place a strong burden on health care services. A timely knowledge of the onset of the epidemic could allow these services to prepare for the peak. We present a method that can reliably identify and signal the influenza outbreak. By combining official Influenza-Like Illness (ILI) incidence rates, searches for ILI-related terms on Google, and an on-call triage phone service, Saúde 24, we were able to identify the beginning of the flu season in 8 European countries, anticipating current official alerts by several weeks. This work shows that it is possible to detect and consistently anticipate the onset of the flu season, in real-time, regardless of the amplitude of the epidemic, with obvious advantages for health care authorities. We also show that the method is not limited to one country, specific region or language, and that it provides a simple and reliable signal that can be used in early detection of other seasonal diseases. PMID:28158192

  2. Blood based cell biopsy for early detection of cancer

    NASA Astrophysics Data System (ADS)

    Tang, Cha-Mei; Adams, Daniel; Adams, Diane; Alpaugh, R. Katherine; Cristofanilli, Massimo; Martin, Stuart; Chumsri, Saranya; Marks, Jeffrey

    Early detection (ED) of cancer holds the promise for less aggressive treatments and better outcome. However, there are few accepted methods for ED. We report on a previously unknown blood cell found specifically in the peripheral blood of many solid tumors. They are defined as Cancer Associated Macrophage-Like cells (CAMLs) and are characterized by large size (25-300 μm) and expression of cancer markers. CAMLs were isolated on precision filters during blood filtration. We conducted prospective studies in breast cancer (BC) to ascertain CAML prevalence, specificity and sensitivity in relation to disease status at clinical presentation. We report on two related but separate studies: 1) the isolation of CAMLs from patients with known invasive BC, compared to healthy volunteers and, 2) a double blind study conducted on women undergoing core needle biopsy to evaluate suspicious breast masses. The studies show that CAMLs are found in all stages of BC and suggest that detection of CAMLs can differentiate patients with BC from those with benign breast conditions and healthy individuals. This non-invasive blood test can be potentially used for ED of BC and other malignancies after validation studies with the advantage of a minimally invasive procedure and longitudinal monitoring. This work was supported by Grants from Maryland TEDCO MTTCF, R01-CA154624 from NIH, KG100240 from Susan G. Komen Foundation, Era of Hope Scholar award from DoD (BC100675), and U01-CA084955 from NCI EDRN.

  3. Generalized Detectability for Discrete Event Systems

    PubMed Central

    Shu, Shaolong; Lin, Feng

    2011-01-01

    In our previous work, we investigated detectability of discrete event systems, which is defined as the ability to determine the current and subsequent states of a system based on observation. For different applications, we defined four types of detectabilities: (weak) detectability, strong detectability, (weak) periodic detectability, and strong periodic detectability. In this paper, we extend our results in three aspects. (1) We extend detectability from deterministic systems to nondeterministic systems. Such a generalization is necessary because there are many systems that need to be modeled as nondeterministic discrete event systems. (2) We develop polynomial algorithms to check strong detectability. The previous algorithms are based on observer whose construction is of exponential complexity, while the new algorithms are based on a new automaton called detector. (3) We extend detectability to D-detectability. While detectability requires determining the exact state of a system, D-detectability relaxes this requirement by asking only to distinguish certain pairs of states. With these extensions, the theory on detectability of discrete event systems becomes more applicable in solving many practical problems. PMID:21691432

  4. Fluorescence detection system for microfluidic droplets

    NASA Astrophysics Data System (ADS)

    Chen, Binyu; Han, Xiaoming; Su, Zhen; Liu, Quanjun

    2018-05-01

    In microfluidic detection technology, because of the universality of optical methods in laboratory, optical detection is an attractive solution for microfluidic chip laboratory equipment. In addition, the equipment with high stability and low cost can be realized by integrating appropriate optical detection technology on the chip. This paper reports a detection system for microfluidic droplets. Photomultiplier tubes (PMT) is used as a detection device to improve the sensitivity of detection. This system improves the signal to noise ratio by software filtering and spatial filter. The fluorescence intensity is proportional to the concentration of the fluorescence and intensity of the laser. The fluorescence micro droplets of different concentrations can be distinguished by this system.

  5. Sensor data monitoring and decision level fusion scheme for early fire detection

    NASA Astrophysics Data System (ADS)

    Rizogiannis, Constantinos; Thanos, Konstantinos Georgios; Astyakopoulos, Alkiviadis; Kyriazanos, Dimitris M.; Thomopoulos, Stelios C. A.

    2017-05-01

    The aim of this paper is to present the sensor monitoring and decision level fusion scheme for early fire detection which has been developed in the context of the AF3 Advanced Forest Fire Fighting European FP7 research project, adopted specifically in the OCULUS-Fire control and command system and tested during a firefighting field test in Greece with prescribed real fire, generating early-warning detection alerts and notifications. For this purpose and in order to improve the reliability of the fire detection system, a two-level fusion scheme is developed exploiting a variety of observation solutions from air e.g. UAV infrared cameras, ground e.g. meteorological and atmospheric sensors and ancillary sources e.g. public information channels, citizens smartphone applications and social media. In the first level, a change point detection technique is applied to detect changes in the mean value of each measured parameter by the ground sensors such as temperature, humidity and CO2 and then the Rate-of-Rise of each changed parameter is calculated. In the second level the fire event Basic Probability Assignment (BPA) function is determined for each ground sensor using Fuzzy-logic theory and then the corresponding mass values are combined in a decision level fusion process using Evidential Reasoning theory to estimate the final fire event probability.

  6. Red-breasted nuthatches detect early increases in spruce budworm populations

    Hewlette S. Crawford; Daniel T. Jennings; Timothy L. Stone

    1990-01-01

    Early suppression .of increasing spruce budworm populations is essential to prevent epidemics; however, early changes in budworm numbers are difficult to detect. An effective and inexpensive method to detect early increases is needed. Red-breasted nuthatches eat more spruce budworm larvae and pupae as the insect increases in number. We estimated the number of large...

  7. Kick Detection at the Bit: Early Detection via Low Cost Monitoring

    SciT

    Tost, Brian; Rose, Kelly; Aminzadeh, Fred

    2016-06-07

    Formation fluid influxes (i.e. kicks) pose persistent challenges and operational costs during drilling operations. Implications of kicks range in scale but cumulatively result in substantial costs that affect drilling safety, environment, schedule, and infrastructure. Early kick detection presents a low-cost, easily adopted solution for avoiding well control challenges associated with kicks near the bit. Borehole geophysical tools used during the drilling process as part of the logging-while-drilling (LWD) and measurement-while-drilling (MWD) provide the advantage of offering real-time downhole data. LWD/MWD collect data on both the annulus and borehole wall. The annular data are normally treated as background, and are filteredmore » out to isolate the formation measurements. Because kicks will change the local physical properties of annular fluids, bottom-hole measurements are among the first indicators that a formation fluid has invaded the wellbore. This report describes and validates a technique for using the annular portion of LWD/MWD data to facilitate early kick detection using first order principles. The detection technique leverages data from standard and cost-effective technologies that are typically implemented during well drilling, such as MWD/LWD data in combination with mud-pulse telemetry for data transmission.« less

  8. On the detection of early osteoarthritis by quantitative microscopic imaging

    NASA Astrophysics Data System (ADS)

    Mittelstaedt, Daniel John

    measurements. These studies demonstrate the ability to use two quantitative microscopic imaging techniques, microCT and microMRI, to detect microscopic changes in collagen and GAG from healthy, biochemically degraded, and early OA cartilage. The capability for microscopic imaging to detect alterations at the earliest stages of OA will ultimately improve the understanding of degradation and may help aid in the detection for the prevention of disease and repair of damaged cartilage.

  9. Electric Field Sensor for Lightning Early Warning System

    NASA Astrophysics Data System (ADS)

    Premlet, B.; Mohammed, R.; Sabu, S.; Joby, N. E.

    2017-12-01

    Electric field mills are used popularly for atmospheric electric field measurements. Atmospheric Electric Field variation is the primary signature for Lightning Early Warning systems. There is a characteristic change in the atmospheric electric field before lightning during a thundercloud formation.A voltage controlled variable capacitance is being proposed as a method for non-contacting measurement of electric fields. A varactor based mini electric field measurement system is developed, to detect any change in the atmospheric electric field and to issue lightning early warning system. Since this is a low-cost device, this can be used for developing countries which are facing adversities. A network of these devices can help in forming a spatial map of electric field variations over a region, and this can be used for more improved atmospheric electricity studies in developing countries.

  10. Detectability of early brain meningitis with magnetic resonance imaging

    SciT

    Runge, V.M.; Wells, J.W.; Williams, N.M.

    1995-08-01

    The ability of high-field (1.5 T) magnetic resonance imaging (MRI) to detect early brain meningitis was evaluated in a canine model. Contrast dose, timing postinjection, and imaging technique (specifically the use of magnetization transfer) were assessed. Imaging of five canines was performed at 1.5 T 24 hours after injection of Cowans staphylococcus into the cisterna magna. Two control animals also were imaged using the same protocol. Contrast doses of 0.1, 0.3, and 0.8 mmol/kg gadoteridol were compared. Scans were performed at 2, 13, and 22 minutes after an initial injection of 0.1 mmol/kg. Thirty minutes after the initial injection ofmore » contrast, a supplemental dose of 0.2 mmol/kg was given. Scans were then repeated at 2, 12, and 22 minutes after this dose was administered. A second supplemental contrast injection of 0.5 mmol/kg was given at 70 minutes, and immediate postinjection scans with and without MT were acquired. Results. In the animals receiving a cisternal injection of bacteria, the degree of meningeal enhancement was greatest at 0.8 mmol/kg, intermediate at 0.3 mmol/kg, and least at 0.1 mmol/kg. Scans in control studies did not demonstrate abnormal meningeal enhancement. High-contrast dose, MT, and acquisition of immediate postcontrast scans all resulted in statistically significant improvement. On masked film review, abnormal meningeal enhancement was noted in only 2 of 5 experimental dogs at a dose of 0.1 mmol/kg (regardless of the use of MT) compared with all animals at a dose of 0.3 mmol/kg. In 18 of 37 dogs (paired scans with and without MT), when abnormal enhancement was noted, the use of MT improved the visualization of abnormal meningeal enhancement. In early brain meningitis, high-contrast dose (0.3 mmol/kg), MT, and scanning immediately after injection improve detection of abnormal meningeal enhancement, thus facilitating the diagnosis of meningitis. Of these factors, contrast dose is the most important. 14 refs., 9 figs., 2 tabs.« less

  11. A tsunami early warning system for the coastal area modeling

    NASA Astrophysics Data System (ADS)

    Soebroto, Arief Andy; Sunaryo, Suhartanto, Ery

    2015-04-01

    The tsunami disaster is a potential disaster in the territory of Indonesia. Indonesia is an archipelago country and close to the ocean deep. The tsunami occurred in Aceh province in 2004. Early prevention efforts have been carried out. One of them is making "tsunami buoy" which has been developed by BPPT. The tool puts sensors on the ocean floor near the coast to detect earthquakes on the ocean floor. Detection results are transmitted via satellite by a transmitter placed floating on the sea surface. The tool will cost billions of dollars for each system. Another constraint was the transmitter theft "tsunami buoy" in the absence of guard. In this study of the system has a transmission system using radio frequency and focused on coastal areas where costs are cheaper, so that it can be applied at many beaches in Indonesia are potentially affected by the tsunami. The monitoring system sends the detection results to the warning system using a radio frequency with a capability within 3 Km. Test results on the sub module sensor monitoring system generates an error of 0.63% was taken 10% showed a good quality sensing. The test results of data transmission from the transceiver of monitoring system to the receiver of warning system produces 100% successful delivery and reception of data. The test results on the whole system to function 100% properly.

  12. Inversion Method for Early Detection of ARES-1 Case Breach Failure

    NASA Technical Reports Server (NTRS)

    Mackey, Ryan M.; Kulikov, Igor K.; Bajwa, Anupa; Berg, Peter; Smelyanskiy, Vadim

    2010-01-01

    A document describes research into the problem of detecting a case breach formation at an early stage of a rocket flight. An inversion algorithm for case breach allocation is proposed and analyzed. It is shown how the case breach can be allocated at an early stage of its development by using the rocket sensor data and the output data from the control block of the rocket navigation system. The results are simulated with MATLAB/Simulink software. The efficiency of an inversion algorithm for a case breach location is discussed. The research was devoted to the analysis of the ARES-l flight during the first 120 seconds after the launch and early prediction of case breach failure. During this time, the rocket is propelled by its first-stage Solid Rocket Booster (SRB). If a breach appears in SRB case, the gases escaping through it will produce the (side) thrust directed perpendicular to the rocket axis. The side thrust creates torque influencing the rocket attitude. The ARES-l control system will compensate for the side thrust until it reaches some critical value, after which the flight will be uncontrollable. The objective of this work was to obtain the start time of case breach development and its location using the rocket inertial navigation sensors and GNC data. The algorithm was effective for the detection and location of a breach in an SRB field joint at an early stage of its development.

  13. Detection of oral early cancerous lesion by using polarization-sensitive optical coherence tomography: mice model

    NASA Astrophysics Data System (ADS)

    Lee, Hong-Yi; Chen, Ping-Hsien; Lee, Tzu-Han; Chang, Kuo-Wei; Kuo, Wen-Chuan

    2018-02-01

    Oral cancer is the 11th most common cancer worldwide, especially in a male adult. The median age of death in oral cancer was 55 years, 10-20 years earlier than other cancers. Presently, oral cancer is often found in late stage, because the lesion is often flat in early stage and is difficult to diagnose under traditional white light imaging. The only definitive method for determining cancer is an invasive biopsy and then using histology examination. How to detect precancerous lesions or early malignant lesions is an important issue for improving prognosis of oral cancer. Optical coherence tomography (OCT) is a new optical tool for diagnosing early malignant lesions in the skin or gastrointestinal tract recently. Here we report a new method for detecting precancerous or early malignant oral lesions by using swept source polarization-sensitive optical coherence tomography (PS-OCT) with center-wavelength 1310 nm, bandwidth 110 nm and 100 kHz swept rate. We used all single-mode fiber design to detect the change of birefringence information in the epithelium structure. This system has an advantage that enables measurement of backscattered intensity and birefringence simultaneously with only one A-scan per transverse location. In preliminary result, we computed the slope of the every A-scan signal in tissue part using a linear-curve fitting in backscattered intensity and birefringence on the enface. In this research, we used an oral cancer mice model for observing the change of structure and birefringence properties in different stages of oral cancer mice. We presented the parametric enface imaging that can detect the early oral malignant lesions.

  14. Effort and Potential Efficiencies for Aquatic Non-native Species Early Detection

    EPA Science Inventory

    This manuscript is based on the early aquatic non-native species detection research in the Duluth-Superior harbor. The problem of early detection is essentially that of a "needle in a haystack" - to detect a newly arrived and presumably rare non-native species with a high probabi...

  15. Early atmospheric detection of carbon dioxide from carbon capture and storage sites.

    PubMed

    Pak, Nasrin Mostafavi; Rempillo, Ofelia; Norman, Ann-Lise; Layzell, David B

    2016-08-01

    The early atmospheric detection of carbon dioxide (CO2) leaks from carbon capture and storage (CCS) sites is important both to inform remediation efforts and to build and maintain public support for CCS in mitigating greenhouse gas emissions. A gas analysis system was developed to assess the origin of plumes of air enriched in CO2, as to whether CO2 is from a CCS site or from the oxidation of carbon compounds. The system measured CO2 and O2 concentrations for different plume samples relative to background air and calculated the gas differential concentration ratio (GDCR = -ΔO2/ΔCO2). The experimental results were in good agreement with theoretical calculations that placed GDCR values for a CO2 leak at 0.21, compared with GDCR values of 1-1.8 for the combustion of carbon compounds. Although some combustion plume samples deviated in GDCR from theoretical, the very low GDCR values associated with plumes from CO2 leaks provided confidence that this technology holds promise in providing a tool for the early detection of CO2 leaks from CCS sites. This work contributes to the development of a cost-effective technology for the early detection of leaks from sites where CO2 has been injected into the subsurface to enhance oil recovery or to permanently store the gas as a strategy for mitigating climate change. Such technology will be important in building public confidence regarding the safety and security of carbon capture and storage sites.

  16. Social Network Sensors for Early Detection of Contagious Outbreaks

    PubMed Central

    Christakis, Nicholas A.; Fowler, James H.

    2010-01-01

    Current methods for the detection of contagious outbreaks give contemporaneous information about the course of an epidemic at best. It is known that individuals near the center of a social network are likely to be infected sooner during the course of an outbreak, on average, than those at the periphery. Unfortunately, mapping a whole network to identify central individuals who might be monitored for infection is typically very difficult. We propose an alternative strategy that does not require ascertainment of global network structure, namely, simply monitoring the friends of randomly selected individuals. Such individuals are known to be more central. To evaluate whether such a friend group could indeed provide early detection, we studied a flu outbreak at Harvard College in late 2009. We followed 744 students who were either members of a group of randomly chosen individuals or a group of their friends. Based on clinical diagnoses, the progression of the epidemic in the friend group occurred 13.9 days (95% C.I. 9.9–16.6) in advance of the randomly chosen group (i.e., the population as a whole). The friend group also showed a significant lead time (p<0.05) on day 16 of the epidemic, a full 46 days before the peak in daily incidence in the population as a whole. This sensor method could provide significant additional time to react to epidemics in small or large populations under surveillance. The amount of lead time will depend on features of the outbreak and the network at hand. The method could in principle be generalized to other biological, psychological, informational, or behavioral contagions that spread in networks. PMID:20856792

  17. Early Detection of Severe Apnoea through Voice Analysis and Automatic Speaker Recognition Techniques

    NASA Astrophysics Data System (ADS)

    Fernández, Ruben; Blanco, Jose Luis; Díaz, David; Hernández, Luis A.; López, Eduardo; Alcázar, José

    This study is part of an on-going collaborative effort between the medical and the signal processing communities to promote research on applying voice analysis and Automatic Speaker Recognition techniques (ASR) for the automatic diagnosis of patients with severe obstructive sleep apnoea (OSA). Early detection of severe apnoea cases is important so that patients can receive early treatment. Effective ASR-based diagnosis could dramatically cut medical testing time. Working with a carefully designed speech database of healthy and apnoea subjects, we present and discuss the possibilities of using generative Gaussian Mixture Models (GMMs), generally used in ASR systems, to model distinctive apnoea voice characteristics (i.e. abnormal nasalization). Finally, we present experimental findings regarding the discriminative power of speaker recognition techniques applied to severe apnoea detection. We have achieved an 81.25 % correct classification rate, which is very promising and underpins the interest in this line of inquiry.

  18. Fusion of Heterogeneous Intrusion Detection Systems for Network Attack Detection

    PubMed Central

    Kaliappan, Jayakumar; Thiagarajan, Revathi; Sundararajan, Karpagam

    2015-01-01

    An intrusion detection system (IDS) helps to identify different types of attacks in general, and the detection rate will be higher for some specific category of attacks. This paper is designed on the idea that each IDS is efficient in detecting a specific type of attack. In proposed Multiple IDS Unit (MIU), there are five IDS units, and each IDS follows a unique algorithm to detect attacks. The feature selection is done with the help of genetic algorithm. The selected features of the input traffic are passed on to the MIU for processing. The decision from each IDS is termed as local decision. The fusion unit inside the MIU processes all the local decisions with the help of majority voting rule and makes the final decision. The proposed system shows a very good improvement in detection rate and reduces the false alarm rate. PMID:26295058

  19. Fusion of Heterogeneous Intrusion Detection Systems for Network Attack Detection.

    PubMed

    Kaliappan, Jayakumar; Thiagarajan, Revathi; Sundararajan, Karpagam

    2015-01-01

    An intrusion detection system (IDS) helps to identify different types of attacks in general, and the detection rate will be higher for some specific category of attacks. This paper is designed on the idea that each IDS is efficient in detecting a specific type of attack. In proposed Multiple IDS Unit (MIU), there are five IDS units, and each IDS follows a unique algorithm to detect attacks. The feature selection is done with the help of genetic algorithm. The selected features of the input traffic are passed on to the MIU for processing. The decision from each IDS is termed as local decision. The fusion unit inside the MIU processes all the local decisions with the help of majority voting rule and makes the final decision. The proposed system shows a very good improvement in detection rate and reduces the false alarm rate.

  20. The role of early detection and treatment in malaria elimination.

    PubMed

    Landier, Jordi; Parker, Daniel M; Thu, Aung Myint; Carrara, Verena I; Lwin, Khin Maung; Bonnington, Craig A; Pukrittayakamee, Sasithon; Delmas, Gilles; Nosten, François H

    2016-07-15

    Falciparum malaria persists in hard-to-reach areas or demographic groups that are missed by conventional healthcare systems but could be reached by trained community members in a malaria post (MP). The main focus of a MP is to provide uninterrupted and rapid access to rapid diagnostic tests (RDTs) and artemisinin-based combination therapy (ACT) too all inhabitants of a village. RDTs allow trained community members to perform malaria diagnosis accurately and prescribe appropriate treatment, reducing as much as possible any delay between the onset of fever and treatment. Early treatment with ACT and with a low-dose of primaquine prevents further transmission from human to mosquito. A functioning MP represents an essential component of any malaria elimination strategy. Implementing large-scale, high-coverage, community-based early diagnosis and treatment through MPs requires few technological innovations but relies on a very well structured organization able to train, supervise and supply MPs, to monitor activity and to perform strict malaria surveillance.

  1. Distant Comets in the Early Solar System

    NASA Technical Reports Server (NTRS)

    Meech, Karen J.

    2000-01-01

    The main goal of this project is to physically characterize the small outer solar system bodies. An understanding of the dynamics and physical properties of the outer solar system small bodies is currently one of planetary science's highest priorities. The measurement of the size distributions of these bodies will help constrain the early mass of the outer solar system as well as lead to an understanding of the collisional and accretional processes. A study of the physical properties of the small outer solar system bodies in comparison with comets in the inner solar system and in the Kuiper Belt will give us information about the nebular volatile distribution and small body surface processing. We will increase the database of comet nucleus sizes making it statistically meaningful (for both Short-Period and Centaur comets) to compare with those of the Trans-Neptunian Objects. In addition, we are proposing to do active ground-based observations in preparation for several upcoming space missions.

  2. Computer-aided detection of early cancer in the esophagus using HD endoscopy images

    NASA Astrophysics Data System (ADS)

    van der Sommen, Fons; Zinger, Svitlana; Schoon, Erik J.; de With, Peter H. N.

    2013-02-01

    Esophageal cancer is the fastest rising type of cancer in the Western world. The recent development of High-Definition (HD) endoscopy has enabled the specialist physician to identify cancer at an early stage. Nevertheless, it still requires considerable effort and training to be able to recognize these irregularities associated with early cancer. As a first step towards a Computer-Aided Detection (CAD) system that supports the physician in finding these early stages of cancer, we propose an algorithm that is able to identify irregularities in the esophagus automatically, based on HD endoscopic images. The concept employs tile-based processing, so our system is not only able to identify that an endoscopic image contains early cancer, but it can also locate it. The identification is based on the following steps: (1) preprocessing, (2) feature extraction with dimensionality reduction, (3) classification. We evaluate the detection performance in RGB, HSI and YCbCr color space using the Color Histogram (CH) and Gabor features and we compare with other well-known features to describe texture. For classification, we employ a Support Vector Machine (SVM) and evaluate its performance using different parameters and kernel functions. In experiments, our system achieves a classification accuracy of 95.9% on 50×50 pixel tiles of tumorous and normal tissue and reaches an Area Under the Curve (AUC) of 0.990. In 22 clinical examples our algorithm was able to identify all (pre-)cancerous regions and annotate those regions reasonably well. The experimental and clinical validation are considered promising for a CAD system that supports the physician in finding early stage cancer.

  3. Early detection of acute kidney injury after pediatric cardiac surgery

    PubMed Central

    Jefferies, John Lynn; Devarajan, Prasad

    2016-01-01

    Acute kidney injury (AKI) is increasingly recognized as a common problem in children undergoing cardiac surgery, with well documented increases in morbidity and mortality in both the short and the long term. Traditional approaches to the identification of AKI such as changes in serum creatinine have revealed a large incidence in this population with significant negative impact on clinical outcomes. However, the traditional diagnostic approaches to AKI diagnosis have inherent limitations that may lead to under-diagnosis of this pathologic process. There is a dearth of randomized controlled trials for the prevention and treatment of AKI associated with cardiac surgery, at least in part due to the paucity of early predictive biomarkers. Novel non-invasive biomarkers have ushered in a new era that allows for earlier detection of AKI. With these new diagnostic tools, a more consistent approach can be employed across centers that may facilitate a more accurate representation of the actual prevalence of AKI and more importantly, clinical investigation that may minimize the occurrence of AKI following pediatric cardiac surgery. A thoughtful management approach is necessary to mitigate the effects of AKI after cardiac surgery, which is best accomplished in close collaboration with pediatric nephrologists. Long-term surveillance for improvement in kidney function and potential development of chronic kidney disease should also be a part of the comprehensive management strategy. PMID:27429538

  4. Early detection strategy and mortality reduction in severe sepsis.

    PubMed

    Westphal, Glauco Adrieno; Feijó, Janaína; Andrade, Patrícia Silva de; Trindade, Louise; Suchard, Cezar; Monteiro, Márcio Andrei Gil; Martins, Sheila Fonseca; Nunes, Fernanda; Caldeira Filho, Milton

    2009-06-01

    To evaluate the impact of implementing an institutional policy for detection of severe sepsis and septic shock. Study before (stage I), after (stage II) with prospective data collection in a 195 bed public hospital.. Stage I: Patients with severe sepsis or septic shock were included consecutively over 15 months and treated according to the Surviving Sepsis Campaign guidelines. Stage II: In the 10 subsequent months, patients with severe sepsis or septic shock were enrolled based on an active search for signs suggesting infection (SSI) in hospitalized patients. The two stages were compared for demographic variables, time needed for recognition of at least two signs suggesting infection (SSI-Δt), compliance to the bundles of 6 and 24 hours and mortality. We identified 124 patients with severe sepsis or septic shock, 68 in stage I and 56 in stage II. The demographic variables were similar in both stages. The Δt-SSI was 34 ± 54 hours in stage I and 7 ± 8.4 hours in stage II (p <0.001). There was no difference in compliance to the bundles. In parallel there was significant reduction of mortality rates at 28 days (54.4% versus 30%, p <0.02) and hospital (67.6% versus 41%, p <0.003). The strategy used helped to identify early risk of sepsis and resulted in decreased mortality associated with severe sepsis and septic shock.

  5. mga genosensor for early detection of human rheumatic heart disease.

    PubMed

    Singh, Swati; Kaushal, Ankur; Khare, Shashi; Kumar, Ashok

    2014-05-01

    The 5' amino-labeled DNA probe complementary to mga gene of Streptococcus pyogenes was immobilized on carboxylated multiwall carbon nanotubes electrode and hybridized with 0.1-100 ng/6 μl single-stranded genomic DNA (ssG-DNA) of S. pyogenes from throat swab of suspected rheumatic heart disease (RHD) patients. Electrochemical response was measured by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance (EI). The sensitivity of the sensor was 106.03 (μA/cm(2))/ng and limit of detection (LOD) was found 0.014 ng/6 μl with regression coefficient (R(2)) of 0.921 using DPV. The genosensor was characterized by FTIR and SEM, and electrode was found stable for 6 months on storage at 4 °C with 5-6 % loss in initial DPV current. mga genosensor is the first report on RHD sensor which can save life of several suspected patients by early diagnosis in 30 min.

  6. Collaborative Early Systems Engineering: Strategic Information Management Review

    DTIC Science & Technology

    2010-09-02

    Early Systems Engineering: Strategic Information Management Review 2 Table of Contents Executive Summary...5  Center for Systems Engineering (CSE) .............................................................................. 6...Collaborative Early Systems Engineering .......................................................................... 6  Development Planning

  7. Imaging and detection of early stage dental caries with an all-optical photoacoustic microscope

    NASA Astrophysics Data System (ADS)

    Hughes, D. A.; Sampathkumar, A.; Longbottom, C.; Kirk, K. J.

    2015-01-01

    Tooth decay, at its earliest stages, manifests itself as small, white, subsurface lesions in the enamel. Current methods for detection in the dental clinic are visual and tactile investigations, and bite-wing X-ray radiographs. These techniques suffer from poor sensitivity and specificity at the earliest (and reversible) stages of the disease due to the small size (<100μm) of the lesion. A fine-resolution (600 nm) ultra-broadband (200 MHz) all-optical photoacoustic microscopy system was is used to image the early signs of tooth decay. Ex-vivo tooth samples exhibiting white spot lesions were scanned and were found to generate a larger (one order of magnitude) photoacoustic (PA) signal in the lesion regions compared to healthy enamel. The high contrast in the PA images potentially allows lesions to be imaged and measured at a much earlier stage than current clinical techniques allow. PA images were cross referenced with histology photographs to validate our experimental results. Our PA system provides a noncontact method for early detection of white-spot lesions with a high detection bandwidth that offers advantages over previously demonstrated ultrasound methods. The technique provides the sensing depth of an ultrasound system, but with the spatial resolution of an optical system.

  8. [Assessment tools in early detection of osteoporosis in dentistry].

    PubMed

    Knezović Zlatarić, Dubravka; Pandurić, Josip; Korsić, Mirko; Dodig, Damir

    2007-03-01

    Osteoporosis, one of the major skeletal diseases in older age, is characterised by low bone mass and microarchitectural deterioration with a resulting increase in bone fragility and hence susceptibility to fracture. In this review we analyse the systemic and local factors associated with oral bone mass loss. Systemic factors most often correlated with the oral bone mass loss include osteoporosis, renal diseases, hormonal disorders, diet and the impact of different drugs on the bony structure. Chronic periodontal disease, early loss of teeth or the effect of inadequate prosthodontic appliance on the residual ridge are the local factors associated with mandibular bone loss. Different assessment tools for the assessment of mandibular oral bone loss have been proposed, such as DXA absorptiometry, quantitative computed tomography, intraoral microdensitometry, SCORE index and the assessment of the thickness and quality of the mandibular inferior cortical border. Qualitative and quantitative assessment of the mandibular bony structure is of great importance in all fields of dentistry - from periodontology to endodontics and prosthodontics, especially in dental implantology. It is important to make the correct indication prior to dental implant therapy, and taking into account the systemic and local factors mentioned above, assess both the actual quality and quantity of the mandible.

  9. Detection and Proportion of Very Early Dental Caries in Independent Living Older Adults

    PubMed Central

    Holtzman, Jennifer S.; Kohanchi, Daniel; Biren-Fetz, John; Fontana, Margherita; Ramchandani, Manisha; Osann, Kathryn; Hallajian, Lucy; Mansour, Stephanie; Nabelsi, Tasneem; Chung, Na Eun; Wilder-Smith, Petra

    2015-01-01

    Background and Objectives Dental caries is an important healthcare challenge in adults over 65 years of age. Integration of oral health screening into non-dental primary care practice may improve access to preventive dental care for vulnerable populations such as the elderly. Such integration would require easy, fast, and accurate early caries detection tools. Primary goal of this study was to evaluate the diagnostic performance of optical coherence tomography (OCT) imaging for detecting very early caries in the elderly living in community-based settings. The International Caries Detection and Assessment System (ICDAS) served as gold standard. Secondary goal of this study was to provide baseline prevalence data of very early caries lesions in independent living adults aged 65+ years. Materials and Methods Seventy-two subjects were recruited from three sites in Southern California: a retirement community, a senior health fair, and a convalescent hospital. Clinical examination was performed using the ICDAS visual criteria and this was followed by OCT imaging. The two-dimensional OCT images (B-scan) were analyzed with simple software. Locations with a log of back-scattered light intensity (BSLI) below 2.9 were scored as sound, and areas equaling or exceeding 2.9 BSLI were considered carious. Diagnostic performance of OCT imaging was compared with ICDAS score. Results OCT-based diagnosis demonstrated very good sensitivity (95.1%) and good specificity (85.8%). 54.7% of dentate subjects had at least one tooth with very early coronal caries. Conclusions Early coronal decay is prevalent in the unrestored pits and fissures of coronal surfaces of teeth in independent living adults aged 65+ years. Though OCT imaging coupled with a simple diagnostic algorithm can accurately detect areas of very early caries in community-based settings, existing devices are expensive and not well-suited for use by non-dental health care providers. Simple, inexpensive, fast, and accurate tools

  10. Nanotechnology-Based Detection of Novel microRNAs for Early Diagnosis of Prostate Cancer

    DTIC Science & Technology

    2017-08-01

    AWARD NUMBER: W81XWH-15-1-0157 TITLE: Nanotechnology -Based Detection of Novel microRNAs for Early Diagnosis of Prostate Cancer PRINCIPAL...TITLE AND SUBTITLE Nanotechnology -Based Detection of Novel microRNAs for Early Diagnosis of Prostate Cancer 5a. CONTRACT NUMBER 5b. GRANT NUMBER...identify novel differentially expressed miRNAs in the body fluids (blood, urine, etc.) for an early detection of PCa. Advances in nanotechnology and

  11. Model Development and Trial of Early Detection Manual for the Special Needs Children at Early Age Education Level

    ERIC Educational Resources Information Center

    Anwar, Zainul; Ingarianti, Tri Muji; Suryaningrum, Cahyaning

    2016-01-01

    This research was aimed to produce the manual for early detection for ABK at the level of early age education (PAUD = "Pendidikan Anak Usia Dini"). Research was "action research" with stages as proposed by Buunk and Van Vugt. Metodology of research these stages were called as PATH ("Problem-Analysis-Test…

  12. Optical-fiber-based laser-induced breakdown spectroscopy for detection of early caries

    NASA Astrophysics Data System (ADS)

    Sasazawa, Shuhei; Kakino, Satoko; Matsuura, Yuji

    2015-06-01

    A laser-induced breakdown spectroscopy (LIBS) system targeting for the in vivo analysis of tooth enamel is described. The system is planned to enable real-time analysis of teeth during laser dental treatment by utilizing a hollow optical fiber that transmits both Q-switched Nd:YAG laser light for LIBS and infrared Er:YAG laser light for tooth ablation. The sensitivity of caries detection was substantially improved by expanding the spectral region under analysis to ultraviolet (UV) light and by focusing on emission peaks of Zn in the UV region. Subsequently, early caries were distinguished from healthy teeth with accuracy rates above 80% in vitro.

  13. Early- versus Late-Onset Systemic Sclerosis

    PubMed Central

    Alba, Marco A.; Velasco, César; Simeón, Carmen Pilar; Fonollosa, Vicent; Trapiella, Luis; Egurbide, María Victoria; Sáez, Luis; Castillo, María Jesús; Callejas, José Luis; Camps, María Teresa; Tolosa, Carles; Ríos, Juan José; Freire, Mayka; Vargas, José Antonio; Espinosa, Gerard

    2014-01-01

    Abstract Peak age at onset of systemic sclerosis (SSc) is between 20 and 50 years, although SSc is also described in both young and elderly patients. We conducted the present study to determine if age at disease onset modulates the clinical characteristics and outcome of SSc patients. The Spanish Scleroderma Study Group recruited 1037 patients with a mean follow-up of 5.2 ± 6.8 years. Based on the mean ± 1 standard deviation (SD) of age at disease onset (45 ± 15 yr) of the whole series, patients were classified into 3 groups: age ≤30 years (early onset), age between 31 and 59 years (standard onset), and age ≥60 years (late onset). We compared initial and cumulative manifestations, immunologic features, and death rates. The early-onset group included 195 patients; standard-onset group, 651; and late-onset, 191 patients. The early-onset group had a higher prevalence of esophageal involvement (72% in early-onset compared with 67% in standard-onset and 56% in late-onset; p = 0.004), and myositis (11%, 7.2%, and 2.9%, respectively; p = 0.009), but a lower prevalence of centromere antibodies (33%, 46%, and 47%, respectively; p = 0.007). In contrast, late-onset SSc was characterized by a lower prevalence of digital ulcers (54%, 41%, and 34%, respectively; p < 0.001) but higher rates of heart conduction system abnormalities (9%, 13%, and 21%, respectively; p = 0.004). Pulmonary hypertension was found in 25% of elderly patients and in 12% of the youngest patients (p = 0.010). After correction for the population effects of age and sex, standardized mortality ratio was shown to be higher in younger patients. The results of the present study confirm that age at disease onset is associated with differences in clinical presentation and outcome in SSc patients. PMID:24646463

  14. Discriminating ultrasonic proximity detection system

    DOEpatents

    Annala, Wayne C.

    1989-01-01

    This invention uses an ultrasonic transmitter and receiver and a microprocessor to detect the presence of an object. In the reset mode the invention uses a plurality of echoes from each ultrasonic burst to create a reference table of the echo-burst-signature of the empty monitored environment. The invention then processes the reference table so that it only uses the most reliable data. In the detection mode the invention compares the echo-burst-signature of the present environment with the reference table, detecting an object if there is a consistent difference between the echo-burst-signature of the empty monitored environment recorded in the reference table and the echo-burst-signature of the present environment.

  15. Detecting COPD exacerbations early using daily telemonitoring of symptoms and k-means clustering: a pilot study.

    PubMed

    Sanchez-Morillo, Daniel; Fernandez-Granero, Miguel Angel; Jiménez, Antonio León

    2015-05-01

    COPD places an enormous burden on the healthcare systems and causes diminished health-related quality of life. The highest proportion of human and economic cost is associated with admissions for acute exacerbation of respiratory symptoms (AECOPD). Since prompt detection and treatment of exacerbations may improve outcomes, early detection of AECOPD is a critical issue. This pilot study was aimed to determine whether a mobile health system could enable early detection of AECOPD on a day-to-day basis. A novel electronic questionnaire for the early detection of COPD exacerbations was evaluated during a 6-months field trial in a group of 16 patients. Pattern recognition techniques were applied. A k-means clustering algorithm was trained and validated, and its accuracy in detecting AECOPD was assessed. Sensitivity and specificity were 74.6 and 89.7 %, respectively, and area under the receiver operating characteristic curve was 0.84. 31 out of 33 AECOPD were early identified with an average of 4.5 ± 2.1 days prior to the onset of the exacerbation that was considered the day of medical attendance. Based on the findings of this preliminary pilot study, the proposed electronic questionnaire and the applied methodology could help to early detect COPD exacerbations on a day-to-day basis and therefore could provide support to patients and physicians.

  16. Sensitivity and accuracy of high-throughput metabarcoding methods for early detection of invasive fish species

    EPA Science Inventory

    For early detection biomonitoring of aquatic invasive species, sensitivity to rare individuals and accurate, high-resolution taxonomic classification are critical to minimize detection errors. Given the great expense and effort associated with morphological identification of many...

  17. Leveraging Biospecimen Resources for Discovery or Validation of Markers for Early Cancer Detection

    PubMed Central

    Carrick, Danielle M.; Mechanic, Leah E.; Srivastava, Sudhir; Anderson, Garnet L.; Baron, John A.; Berg, Christine D.; Cullen, Jennifer; Diamandis, Eleftherios P.; Doria-Rose, V. Paul; Goddard, Katrina A. B.; Hankinson, Susan E.; Kushi, Lawrence H.; Larson, Eric B.; McShane, Lisa M.; Schilsky, Richard L.; Shak, Steven; Skates, Steven J.; Urban, Nicole; Kramer, Barnett S.; Khoury, Muin J.; Ransohoff, David F.

    2015-01-01

    Validation of early detection cancer biomarkers has proven to be disappointing when initial promising claims have often not been reproducible in diagnostic samples or did not extend to prediagnostic samples. The previously reported lack of rigorous internal validity (systematic differences between compared groups) and external validity (lack of generalizability beyond compared groups) may be effectively addressed by utilizing blood specimens and data collected within well-conducted cohort studies. Cohort studies with prediagnostic specimens (eg, blood specimens collected prior to development of clinical symptoms) and clinical data have recently been used to assess the validity of some early detection biomarkers. With this background, the Division of Cancer Control and Population Sciences (DCCPS) and the Division of Cancer Prevention (DCP) of the National Cancer Institute (NCI) held a joint workshop in August 2013. The goal was to advance early detection cancer research by considering how the infrastructure of cohort studies that already exist or are being developed might be leveraged to include appropriate blood specimens, including prediagnostic specimens, ideally collected at periodic intervals, along with clinical data about symptom status and cancer diagnosis. Three overarching recommendations emerged from the discussions: 1) facilitate sharing of existing specimens and data, 2) encourage collaboration among scientists developing biomarkers and those conducting observational cohort studies or managing healthcare systems with cohorts followed over time, and 3) conduct pilot projects that identify and address key logistic and feasibility issues regarding how appropriate specimens and clinical data might be collected at reasonable effort and cost within existing or future cohorts. PMID:25688116

  18. Clinical Perspective of 3D Total Body Photography for Early Detection and Screening of Melanoma.

    PubMed

    Rayner, Jenna E; Laino, Antonia M; Nufer, Kaitlin L; Adams, Laura; Raphael, Anthony P; Menzies, Scott W; Soyer, H Peter

    2018-01-01

    Melanoma incidence continues to increase across many populations globally and there is significant mortality associated with advanced disease. However, if detected early, patients have a very promising prognosis. The methods that have been utilized for early detection include clinician and patient skin examinations, dermoscopy (static and sequential imaging), and total body photography via 2D imaging. Total body photography has recently witnessed an evolution from 2D imaging with the ability to now create a 3D representation of the patient linked with dermoscopy images of individual lesions. 3D total body photography is a particularly beneficial screening tool for patients at high risk due to their personal or family history or those with multiple dysplastic naevi-the latter can make monitoring especially difficult without the assistance of technology. In this perspective, we discuss clinical examples utilizing 3D total body photography, associated advantages and limitations, and future directions of the technology. The optimal system for melanoma screening should improve diagnostic accuracy, be time and cost efficient, and accessible to patients across all demographic and socioeconomic groups. 3D total body photography has the potential to address these criteria and, most importantly, optimize crucial early detection.

  19. Early detection of ocean acidification effects on marine calcification

    SciT

    Ilyina, T.; Zeebe, R. E.; E. Maier-Reimer

    Ocean acidification is likely to impact calcification rates in many pelagic organisms, which may in turn cause significant changes in marine ecosystem structure. We examine effects of changes in marine CaCO3 production on total alkalinity (TA) in the ocean using the global biogeochemical ocean model HAMOCC. We test a variety of future calcification scenarios because experimental studies with different organisms have revealed a wide range of calcification sensitivities to CaCO3 saturation state. The model integrations start at a preindustrial steady state in the year 1800 and run until the year 2300 forced with anthropogenic CO2 emissions. Calculated trends in TAmore » are evaluated taking into account the natural variability in ocean carbonate chemistry, as derived from repeat hydrographic transects. We conclude that the data currently available does not allow discerning significant trends in TA due to changes in pelagic calcification caused by ocean acidification. Given different calcification scenarios, our model calculations indicate that the TA increase over time will start being detectable by the year 2040, increasing by 5–30 umol/kg compared to the present-day values. In a scenario of extreme reductions in calcification, large TA changes relative to preindustrial conditions would have occurred at present, which we consider very unlikely. However, the time interval of reliable TA observations is too short to disregard this scenario. The largest increase in surface ocean TA is predicted for the tropical and subtropical regions. In order to monitor and quantify possible early signs of acidification effects, we suggest to specifically target those regions during future ocean chemistry surveys.« less

  20. Early detection of Candida albicans biofilms at porous electrodes.

    PubMed

    Congdon, Robert B; Feldberg, Alexander S; Ben-Yakar, Natalie; McGee, Dennis; Ober, Christopher; Sammakia, Bahgat; Sadik, Omowunmi A

    2013-02-15

    We describe the development of an electrochemical sensor for early detection of biofilm using Candida albicans. The electrochemical sensor used the ability of biofilms to accept electrons from redox mediators relative to the number of metabolically active cells present. Cyclic voltammetry and differential pulse voltammetry techniques were used to monitor the redox reaction of K(3)Fe(CN)(6) at porous reticulated vitreous carbon (RVC) (238.7 cm(2)) working electrodes versus Ag/AgCl reference. A shift in the peak potential occurred after 12 h of film growth, which is attributed to the presence of C. albicans. Moreover, the intensity of the ferricyanide reduction peak first increased as C. albicans deposited onto the porous electrodes at various growth times. The peak current subsequently decreased at extended periods of growth of 48 h. The reduction in peak current was attributed to the biofilm reaching its maximum growth thickness, which correlated with the maximum number of metabolically active cells. The observed diffusion coefficients for the bare RVC and biofilm-coated electrodes were 2.2 × 10(-3) and 7.0 × 10(-6) cm(2)/s, respectively. The increase in diffusivity from the bare electrode to the biofilm-coated electrode indicated some enhancement of electron transfer mediated by the biofilm to the porous electrode. Verification of the growth of biofilm was achieved using scanning electron microcopy and laser scanning confocal imaging microscopy. Validation with conventional plating techniques confirmed that the correlation (R(2) = 0.9392) could be achieved between the electrochemical sensors data and colony-forming units. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Hybrid Intrusion Forecasting Framework for Early Warning System

    NASA Astrophysics Data System (ADS)

    Kim, Sehun; Shin, Seong-Jun; Kim, Hyunwoo; Kwon, Ki Hoon; Han, Younggoo

    Recently, cyber attacks have become a serious hindrance to the stability of Internet. These attacks exploit interconnectivity of networks, propagate in an instant, and have become more sophisticated and evolutionary. Traditional Internet security systems such as firewalls, IDS and IPS are limited in terms of detecting recent cyber attacks in advance as these systems respond to Internet attacks only after the attacks inflict serious damage. In this paper, we propose a hybrid intrusion forecasting system framework for an early warning system. The proposed system utilizes three types of forecasting methods: time-series analysis, probabilistic modeling, and data mining method. By combining these methods, it is possible to take advantage of the forecasting technique of each while overcoming their drawbacks. Experimental results show that the hybrid intrusion forecasting method outperforms each of three forecasting methods.

  2. Education concerning carcinoma of prostate and its early detection

    PubMed Central

    Jędrzejewska, Sylwia

    2011-01-01

    Introduction and objectives Prostate cancer is the most common male cancer. Insufficient knowledge of PCa among men causes its low detection. Lack of essential actions in health education and widely understood prophylaxis, the need of the latter are maybe responsible for the increasing mortality rate. According to our assumption, educating men increase their awareness on the need of screening tests and results in increasing reporting to physical examinations. This in turn allows for an early detection of the disease. Material and methods A research was conducted between the years 2003-2009 on the knowledge of PCa among 260 men. They were divided into two groups. Group A – 63 patients treated for carcinoma of prostate and group B – 197 men reporting spontaneously to screening tests. In order to check the adopted hypothesis, we prepared an educational material and test of knowledge – test with a questionnaire. Knowledge was evaluated before (test I) and after the education process (test II). Until 2009, we were monitoring the number of patients from group B reporting to screening tests and their knowledge was once again checked (test III). Two subgroups C and D were created from group B – 117 healthy men and 80 with diagnosed diseases respectively (70 with benign prostatic hyperplasia, 7 with prostatitis, and 3 with carcinoma of prostate). Patients with prostatitis and PCa and 3 patients from group C not reporting to the tests were excluded from further monitoring. Maths statistics with the use of SPSS 12.0 PL program and Statistica 6.0 constituted the base for working out the results. Results We observed a higher knowledge about carcinoma of prostate in group A than in group B (p <0.0001) and it increased after 5 years in group D (p <0.0001) in comparison to group C. Patients aged >40 from groups C and D were interested in health care (p<0.01) as much as patients aged 40-49, 50-59 and 60-69. In men >70 a lower level of motivation was observed. The interest

  3. Education concerning carcinoma of prostate and its early detection.

    PubMed

    Dutkiewcz, Sławomir; Jędrzejewska, Sylwia

    2011-01-01

    Prostate cancer is the most common male cancer. Insufficient knowledge of PCa among men causes its low detection. Lack of essential actions in health education and widely understood prophylaxis, the need of the latter are maybe responsible for the increasing mortality rate. According to our assumption, educating men increase their awareness on the need of screening tests and results in increasing reporting to physical examinations. This in turn allows for an early detection of the disease. A research was conducted between the years 2003-2009 on the knowledge of PCa among 260 men. They were divided into two groups. Group A - 63 patients treated for carcinoma of prostate and group B - 197 men reporting spontaneously to screening tests. In order to check the adopted hypothesis, we prepared an educational material and test of knowledge - test with a questionnaire. Knowledge was evaluated before (test I) and after the education process (test II). Until 2009, we were monitoring the number of patients from group B reporting to screening tests and their knowledge was once again checked (test III). Two subgroups C and D were created from group B - 117 healthy men and 80 with diagnosed diseases respectively (70 with benign prostatic hyperplasia, 7 with prostatitis, and 3 with carcinoma of prostate). Patients with prostatitis and PCa and 3 patients from group C not reporting to the tests were excluded from further monitoring. Maths statistics with the use of SPSS 12.0 PL program and Statistica 6.0 constituted the base for working out the results. We observed a higher knowledge about carcinoma of prostate in group A than in group B (p <0.0001) and it increased after 5 years in group D (p <0.0001) in comparison to group C. Patients aged >40 from groups C and D were interested in health care (p<0.01) as much as patients aged 40-49, 50-59 and 60-69. In men >70 a lower level of motivation was observed. The interest was proportional to the level of education, and this was

  4. Hepatocellular Carcinoma Screening Associated with Early Tumor Detection and Improved Survival Among Patients with Cirrhosis in the US.

    PubMed

    Singal, Amit G; Mittal, Sahil; Yerokun, Olutola A; Ahn, Chul; Marrero, Jorge A; Yopp, Adam C; Parikh, Neehar D; Scaglione, Steve J

    2017-09-01

    Professional societies recommend hepatocellular carcinoma screening in patients with cirrhosis, but high-quality data evaluating its effectiveness to improve early tumor detection and survival in "real world" clinical practice are needed. We aim to characterize the association between hepatocellular carcinoma screening and early tumor detection, curative treatment, and overall survival among patients with cirrhosis. We performed a retrospective cohort study of patients diagnosed with hepatocellular carcinoma between June 2012 and May 2013 at 4 health systems in the US. Patients were categorized in the screening group if hepatocellular carcinoma was detected by imaging performed for screening purposes. Generalized linear models and multivariate Cox regression with frailty adjustment were used to compare early detection, curative treatment, and survival between screen-detected and non-screen-detected patients. Among 374 hepatocellular carcinoma patients, 42% (n = 157) were detected by screening. Screen-detected patients had a significantly higher proportion of early tumors (Barcelona Clinic Liver Cancer stage A 63.1% vs 36.4%, P <.001) and were more likely to undergo curative treatment (31% vs 13%, P = .02). Hepatocellular carcinoma screening was significantly associated with improved survival in multivariate analysis (hazards ratio 0.41; 95% confidence interval, 0.26-0.65) after adjusting for patient demographics, Child-Pugh class, and performance status. Median survival of screen-detected patients was 14.6 months, compared with 6.0 months for non-screen-detected patients, with the difference remaining significant after adjusting for lead-time bias (hazards ratio 0.59, 95% confidence interval, 0.37-0.93). Hepatocellular carcinoma screening is associated with increased early tumor detection and improved survival; however, a minority of hepatocellular carcinoma patients are detected by screening. Interventions to increase screening use in patients with cirrhosis may

  5. Toward detecting deception in intelligent systems

    NASA Astrophysics Data System (ADS)

    Santos, Eugene, Jr.; Johnson, Gregory, Jr.

    2004-08-01

    Contemporary decision makers often must choose a course of action using knowledge from several sources. Knowledge may be provided from many diverse sources including electronic sources such as knowledge-based diagnostic or decision support systems or through data mining techniques. As the decision maker becomes more dependent on these electronic information sources, detecting deceptive information from these sources becomes vital to making a correct, or at least more informed, decision. This applies to unintentional disinformation as well as intentional misinformation. Our ongoing research focuses on employing models of deception and deception detection from the fields of psychology and cognitive science to these systems as well as implementing deception detection algorithms for probabilistic intelligent systems. The deception detection algorithms are used to detect, classify and correct attempts at deception. Algorithms for detecting unexpected information rely upon a prediction algorithm from the collaborative filtering domain to predict agent responses in a multi-agent system.

  6. Intrusion Detection Systems with Live Knowledge System

    DTIC Science & Technology

    2016-05-31

    Ripple -down Rule (RDR) to maintain the knowledge from human experts with knowledge base generated by the Induct RDR, which is a machine-learning based RDR...propose novel approach that uses Ripple -down Rule (RDR) to maintain the knowledge from human experts with knowledge base generated by the Induct RDR...detection model by applying Induct RDR approach. The proposed induct RDR ( Ripple Down Rules) approach allows to acquire the phishing detection

  7. An automatically tuning intrusion detection system.

    PubMed

    Yu, Zhenwei; Tsai, Jeffrey J P; Weigert, Thomas

    2007-04-01

    An intrusion detection system (IDS) is a security layer used to detect ongoing intrusive activities in information systems. Traditionally, intrusion detection relies on extensive knowledge of security experts, in particular, on their familiarity with the computer system to be protected. To reduce this dependence, various data-mining and machine learning techniques have been deployed for intrusion detection. An IDS is usually working in a dynamically changing environment, which forces continuous tuning of the intrusion detection model, in order to maintain sufficient performance. The manual tuning process required by current systems depends on the system operators in working out the tuning solution and in integrating it into the detection model. In this paper, an automatically tuning IDS (ATIDS) is presented. The proposed system will automatically tune the detection model on-the-fly according to the feedback provided by the system operator when false predictions are encountered. The system is evaluated using the KDDCup'99 intrusion detection dataset. Experimental results show that the system achieves up to 35% improvement in terms of misclassification cost when compared with a system lacking the tuning feature. If only 10% false predictions are used to tune the model, the system still achieves about 30% improvement. Moreover, when tuning is not delayed too long, the system can achieve about 20% improvement, with only 1.3% of the false predictions used to tune the model. The results of the experiments show that a practical system can be built based on ATIDS: system operators can focus on verification of predictions with low confidence, as only those predictions determined to be false will be used to tune the detection model.

  8. CFD modelling of sampling locations for early detection of spontaneous combustion in long-wall gob areas.

    PubMed

    Yuan, Liming; Smith, Alex C

    In this study, computational fluid dynamics (CFD) modeling was conducted to optimize gas sampling locations for the early detection of spontaneous heating in longwall gob areas. Initial simulations were carried out to predict carbon monoxide (CO) concentrations at various regulators in the gob using a bleeder ventilation system. Measured CO concentration values at these regulators were then used to calibrate the CFD model. The calibrated CFD model was used to simulate CO concentrations at eight sampling locations in the gob using a bleederless ventilation system to determine the optimal sampling locations for early detection of spontaneous combustion.

  9. Flood Monitoring and Early Warning System Using Ultrasonic Sensor

    NASA Astrophysics Data System (ADS)

    Natividad, J. G.; Mendez, J. M.

    2018-03-01

    The purpose of this study is to develop a real-time flood monitoring and early warning system in the northern portion of the province of Isabela, particularly the municipalities near Cagayan River. Ultrasonic sensing techniques have become mature and are widely used in the various fields of engineering and basic science. One of advantage of ultrasonic sensing is its outstanding capability to probe inside objective non-destructively because ultrasound can propagate through any kinds of media including solids, liquids and gases. This study focuses only on the water level detection and early warning system (via website and/or SMS) that alerts concern agencies and individuals for a potential flood event. Furthermore, inquiry system is also included in this study to become more interactive wherein individuals in the community could inquire the actual water level and status of the desired area or location affected by flood thru SMS keyword. The study aims in helping citizens to be prepared and knowledgeable whenever there is a flood. The novelty of this work falls under the utilization of the Arduino, ultrasonic sensors, GSM module, web-monitoring and SMS early warning system in helping stakeholders to mitigate casualties related to flood. The paper envisions helping flood-prone areas which are common in the Philippines particularly to the local communities in the province. Indeed, it is relevant and important as per needs for safety and welfare of the community.

  10. Early Detection of Rapidly Developing Cumulus Area using HIMAWARI-8

    NASA Astrophysics Data System (ADS)

    Yamada, Y.; Kadosaki, G.

    2017-12-01

    In recent years, many disasters have been occured by influence of meteorological change in Japan. So, it becomes more important to inform rapid weather change caused by cumulus which brings concentrated heavy rain/hail, wind gust, lightning in a short period. These severe events should inclease in the future by global warming. Therefore we are developping the alert system for Rapidly Developing Cumulus Area (RDCA) detection using Japanese new satellite. At July 2015, Japan Meteorological Agency started operation of new geostationary meteorological satellite "Himawari-8". This satellite has optical imager named Advanced Himawari Imager (AHI). It can observe Japan area every 2.5 minutes. The frequently infrared image with high resolution (2km) is the key of our alert system. We took some special functions in the algorithm of this system. One of the points is cloud location which shifts to north from true location around Japan by viewing angle from the satellite above the equator. We moved clouds to the correct position using geometric correction method according to its height and latitude. This algorithm also follows a movement of cloud every 2.5 minutes during several observations. It derives the information about degree of the development of cumulus. The prototype system gives the alert before 30 to 60 minutes in advance to the first lightning in typical cumulus case. However, we understand that there are some difficult cases to alert. For example, winter low cloud over the Japan Sea which brings a winter lightning, and tornado (although it is not cumulus). Now, we are adjusting some parameters of the algorithm. In the near future, our algorithm will be used in weather information delivery service to the customer.

  11. Ballistic Missile Early Warning System Clear Air Force Station, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Ballistic Missile Early Warning System - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  12. Alaskan Air Defense and Early Warning Systems Clear Air ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Alaskan Air Defense and Early Warning Systems - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  13. Early detection of ventricular tachycardia with sending messages to cell phone

    NASA Astrophysics Data System (ADS)

    Ramirez, L. J.; Lozano, F. A.; Rondon, C. R.

    2011-09-01

    Sustained ventricular tachycardia (VTs) can be asymptomatic for some people, but for other is deadly because it is a major cause of sudden cardiac death [1]. Some patients may present this arrhythmia, and even so, they decide to drive car increasing the likelihood of VTs, putting at risk not only his life but that of the other drivers. We developed a system for early detection of VTs, consisting of EKG sensors, a card of processing and a cell phone, which detects this arrhythmia, gives an alarm signal to the driver, and it simultaneously sending to text messages a specialist doctor and a relative or friend, all in real time. This design was conditioned to the car, is light and comfortable, that allowed that work of car's driver without discomfort. This system will save lives, since in case of emergency sends a help message, no matter where you are in the driver.

  14. Effectiveness of distributed temperature measurements for early detection of piping in river embankments

    NASA Astrophysics Data System (ADS)

    Bersan, Silvia; Koelewijn, André R.; Simonini, Paolo

    2018-02-01

    Internal erosion is the cause of a significant percentage of failure and incidents involving both dams and river embankments in many countries. In the past 20 years the use of fibre-optic Distributed Temperature Sensing (DTS) in dams has proved to be an effective tool for the detection of leakages and internal erosion. This work investigates the effectiveness of DTS for dike monitoring, focusing on the early detection of backward erosion piping, a mechanism that affects the foundation layer of structures resting on permeable, sandy soils. The paper presents data from a piping test performed on a large-scale experimental dike equipped with a DTS system together with a large number of accompanying sensors. The effect of seepage and piping on the temperature field is analysed, eventually identifying the processes that cause the onset of thermal anomalies around piping channels and thus enable their early detection. Making use of dimensional analysis, the factors that influence this thermal response of a dike foundation are identified. Finally some tools are provided that can be helpful for the design of monitoring systems and for the interpretation of temperature data.

  15. Molecular clocks and the early evolution of metazoan nervous systems.

    PubMed

    Wray, Gregory A

    2015-12-19

    The timing of early animal evolution remains poorly resolved, yet remains critical for understanding nervous system evolution. Methods for estimating divergence times from sequence data have improved considerably, providing a more refined understanding of key divergences. The best molecular estimates point to the origin of metazoans and bilaterians tens to hundreds of millions of years earlier than their first appearances in the fossil record. Both the molecular and fossil records are compatible, however, with the possibility of tiny, unskeletonized, low energy budget animals during the Proterozoic that had planktonic, benthic, or meiofaunal lifestyles. Such animals would likely have had relatively simple nervous systems equipped primarily to detect food, avoid inhospitable environments and locate mates. The appearance of the first macropredators during the Cambrian would have changed the selective landscape dramatically, likely driving the evolution of complex sense organs, sophisticated sensory processing systems, and diverse effector systems involved in capturing prey and avoiding predation. © 2015 The Author(s).

  16. Early detection monitoring of Phytophthora ramorum in high-risk forests of California

    Ross Meentemeyer; Elizabeth Lotz; David M. Rizzo; Kelly Buja; Walter Mark

    2006-01-01

    Early detection monitoring is essential for successful control of invasive organisms. Detection of invasions at an early stage of establishment when a population is small and isolated makes eradication more feasible and less costly. Sudden oak death, caused by the recently described pathogen Phytophthora ramorum, is an emerging forest disease that...

  17. Advancing Early Detection of Autism Spectrum Disorder by Applying an Integrated Two-Stage Screening Approach

    ERIC Educational Resources Information Center

    Oosterling, Iris J.; Wensing, Michel; Swinkels, Sophie H.; van der Gaag, Rutger Jan; Visser, Janne C.; Woudenberg, Tim; Minderaa, Ruud; Steenhuis, Mark-Peter; Buitelaar, Jan K.

    2010-01-01

    Background: Few field trials exist on the impact of implementing guidelines for the early detection of autism spectrum disorders (ASD). The aims of the present study were to develop and evaluate a clinically relevant integrated early detection programme based on the two-stage screening approach of Filipek et al. (1999), and to expand the evidence…

  18. Design and characterization of a dead-time regime enhanced early photon projection imaging system

    NASA Astrophysics Data System (ADS)

    Sinha, L.; Fogarty, M.; Zhou, W.; Giudice, A.; Brankov, J. G.; Tichauer, K. M.

    2018-04-01

    Scattering of visible and near-infrared light in biological tissue reduces spatial resolution for imaging of tissues thicker than 100 μm. In this study, an optical projection imaging system is presented and characterized that exploits the dead-time characteristics typical of photon counting modules based on single photon avalanche diodes (SPADs). With this system, it is possible to attenuate the detection of more scattered late-arriving photons, such that detection of less scattered early-arriving photons can be enhanced with increased light intensity, without being impeded by the maximum count rate of the SPADs. The system has the potential to provide transmittance-based anatomical information or fluorescence-based functional information (with slight modification in the instrumentation) of biological samples with improved resolution in the mesoscopic domain (0.1-2 cm). The system design, calibration, stability, and performance were evaluated using simulation and experimental phantom studies. The proposed system allows for the detection of very-rare early-photons at a higher frequency and with a better signal-to-noise ratio. The experimental results demonstrated over a 3.4-fold improvement in the spatial resolution using early photon detection vs. conventional detection, and a 1000-fold improvement in imaging time using enhanced early detection vs. conventional early photon detection in a 4-mm thick phantom with a tissue-equivalent absorption coefficient of μa = 0.05 mm-1 and a reduced scattering coefficient of μs' = 5 mm-1.

  19. The importance of early detection of lip cancer risk groups

    NASA Astrophysics Data System (ADS)

    Fratila, M.; Rosu, S.

    2014-03-01

    in frequency as well as in the therapeutic problems raised. In the face and oral cavity cancer catagory, lip represents 2% of all cases and 19-25% of the total facial cancer area. Lip cancer is one of the localizations that, when detected early, can benefit from an effective therapy with high chances of healing. In order to achieve a complex treatment, interdisciplinary collaboration is required, only thus being able to determine both the therapeutic methods as well as their association.

  20. Predictive algorithms for early detection of retinopathy of prematurity.

    PubMed

    Piermarocchi, Stefano; Bini, Silvia; Martini, Ferdinando; Berton, Marianna; Lavini, Anna; Gusson, Elena; Marchini, Giorgio; Padovani, Ezio Maria; Macor, Sara; Pignatto, Silvia; Lanzetta, Paolo; Cattarossi, Luigi; Baraldi, Eugenio; Lago, Paola

    2017-03-01

    To evaluate sensitivity, specificity and the safest cut-offs of three predictive algorithms (WINROP, ROPScore and CHOP ROP) for retinopathy of prematurity (ROP). A retrospective study was conducted in three centres from 2012 to 2014; 445 preterms with gestational age (GA) ≤ 30 weeks and/or birthweight (BW) ≤ 1500 g, and additional unstable cases, were included. No-ROP, mild and type 1 ROP were categorized. The algorithms were analysed for infants with all parameters (GA, BW, weight gain, oxygen therapy, blood transfusion) needed for calculation (399 babies). Retinopathy of prematurity (ROP) was identified in both eyes in 116 patients (26.1%), and 44 (9.9%) had type 1 ROP. Gestational age and BW were significantly lower in ROP group compared with no-ROP subjects (GA: 26.7 ± 2.2 and 30.2 ± 1.9, respectively, p < 0.0001; BW: 839.8 ± 287.0 and 1288.1 ± 321.5 g, respectively, p = 0.0016). Customized alarms of ROPScore and CHOP ROP correctly identified all infants having any ROP or type 1 ROP. WINROP missed 19 cases of ROP, including three type 1 ROP. ROPScore and CHOP ROP provided the best performances with an area under the receiver operating characteristic curve for the detection of severe ROP of 0.93 (95% CI, 0.90-0.96, and 95% CI, 0.89-0.96, respectively), and WINROP obtained 0.83 (95% CI, 0.77-0.87). Median time from alarm to treatment was 11.1, 5.1 and 9.1 weeks, for WINROP, ROPScore and CHOP ROP, respectively. ROPScore and CHOP ROP showed 100% sensitivity to identify sight-threatening ROP. Predictive algorithms are a reliable tool for early identification of infants requiring referral to an ophthalmologist, for reorganizing resources and reducing stressful procedures to preterm babies. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  1. How can clinicians detect and treat autism early? Methodological trends of technology use in research

    PubMed Central

    Bölte, S; Bartl-Pokorny, KD; Jonsson, U; Berggren, S; Zhang, D; Kostrzewa, E; Falck-Ytter, T; Einspieler, C; Pokorny, FB; Jones, EJH; Roeyers, H; Charman, T; Marschik, PB

    2018-01-01

    We reviewed original research papers that used quantifiable technology to detect early autism spectrum disorder (ASD) and identified 376 studies from 34 countries from 1965-2013. Publications have increased significantly since 2000, with most coming from the USA. Electroencephalogram, magnetic resonance imaging and eye-tracking were the most frequently used technologies. Conclusion The use of quantifiable technology to detect early ASD has increased in recent decades, but has had limited impact on early detection and treatment. Further scientific developments are anticipated and we hope that they will increasingly be used in clinical practice for early ASD screening, diagnosis and intervention. PMID:26479859

  2. Detection of selected periodontal bacteria in preschool children affected by early childhood caries.

    PubMed

    Pantuckova, Pavla; Bartosova, Michaela; Broukal, Zdenek; Kukletova, Martina; Holla, Lydie Izakovicova

    2016-11-01

    The aim of this study was to compare the detection frequency of periodontal bacteria in dental plaque in children with early childhood caries (ECC) with and without gingival inflammation. A convenience sample of 25 preschool children (mean age 3.61 years, SD 1.42) was recruited. Dental plaque was taken from periodontal areas with and without visible signs of inflammation and processed using the StomaGene® (Protean s.r.o. Czech Republic) and ParoCheck® 20 (Greiner Bio-one GmbH, Germany) detection kits. The two sample t tests between percents for differences between inflammatory and healthy sites and kappa statistics for the agreement of both systems were used. At the inflammatory sites, Porphyromonas gingivalis and Aggregatibacter actinomycetemcomitans were significantly more frequently detected by StomaGene® while Fusobacterium nucleatum, A. actinomycetemcomitans, Tanarella forsythia and Prevotella intermedia were significantly more frequently identified by ParoCheck® test. The agreement between the two detection systems was substantial for A. actinomycetemcomitans and F. nucleatum in the samples collected from inflamed sites and only for F. nucleatum from clinically healthy sites. Therefore, we recommend that the same system should be used when the same patient is examined repeatedly.

  3. Detection of phosphatidylserine-positive exosomes for the diagnosis of early-stage malignancies.

    PubMed

    Sharma, Raghava; Huang, Xianming; Brekken, Rolf A; Schroit, Alan J

    2017-08-08

    There has been increasing interest in the detection of tumour exosomes in blood for cancer diagnostics. Most studies have focussed on miRNA and protein signatures that are surrogate markers for specific tumour types. Because tumour cells and tumour-derived exosomes display phosphatidylserine (PS) in their outer membrane leaflet, we developed a highly sensitive ELISA-based system that detects picogram amounts of exosomal phospholipid in plasma as a cancer biomarker. This report describes the development of a highly specific and sensitive ELISA for the capture of PS-expressing tumour exosomes in the blood of tumour-bearing mice. To monitor the relationship between tumour burden and tumour exosome plasma concentrations, plasma from one transplantable breast cancer model (MDA-MB-231) and three genetic mouse models (MMTV-PyMT; breast and KIC and KPC; pancreatic) were screened for captured exosomal phospholipid. We show that quantitative assessment of PS-expressing tumour exosomes detected very early-stage malignancies before clinical evidence of disease in all four model systems. Tumour exosome levels showed significant increases by day 7 after tumour implantation in the MDA-MB-231 model while palpable tumours appeared only after day 27. For the MMTV-PyMT and KIC models, tumour exosome levels increased significantly by day 49 (P⩽0.0002) and day 21 (P⩽0.001) while tumours developed only after days 60 and 40, respectively. For the KPC model, a significant increase in blood exosome levels was detected by day 70 (P=0.023) when only preinvasive lesions are microscopically detectable. These data indicate that blood PS exosome levels is a specific indicator of cancer and suggest that blood PS is a biomarker for early-stage malignancies.

  4. Important first encounter: Service user experience of pathways to care and early detection in first-episode psychosis.

    PubMed

    Jansen, Jens Einar; Pedersen, Marlene Buch; Hastrup, Lene Halling; Haahr, Ulrik Helt; Simonsen, Erik

    2018-04-01

    Long duration of untreated psychosis is associated with poor clinical and functional outcomes. However, few systematic attempts have been made to reduce this delay and little is known of service users' experience of early detection efforts. We explored service users' experience of an early detection service and transition to specialized treatment service, including pathway to care, understanding of illness and barriers to adequate assessment and treatment. In-depth interviews were conducted with 10 service users (median age 21, range 18-27, five males and five females) who were diagnosed with a first-episode non-affective psychosis and who were seen by an early detection team (TOP) and currently enrolled in a specialized early intervention service for this disorder (OPUS). Stigma and fear of the 'psychiatric system' were reported as significant barriers to help seeking, while family members were seen as a crucial support. Moreover, the impact of traumatic events on the experience and development of psychosis was highlighted. Finally, participants were relieved by the prospect of receiving help and the early detection team seemed to create a trusting relationship by offering a friendly, 'anti-stigmatized' space, where long-term symptomatology could be disclosed through accurate and validating questioning. Early detection services have two important functions. One is to make accurate assessments and referrals. The other is to instil hope and trust, and to facilitate further treatment by forming an early therapeutic alliance. The findings in this study provide important insights into the way in which early detection efforts and pathways to care are experienced by service users, with direct implications for improving psychiatric services. © 2015 Wiley Publishing Asia Pty Ltd.

  5. Phospholamban, a predicted candidate for early cardiac problem detection using signal processing techniques.

    PubMed

    Hejase de Trad, C

    2005-01-01

    Heart failure has been identified as a serious international problem, in particular for aging groups, posing both an increasing number of patients on waiting lists in countries susceptible with Medicare systems and increasing financial burdens. It may be imperative to develop a marker that can identify such problems at an early stage. It is believed that certain proteins have crucial roles in early detection of cardiovascular disease, the number one killer in United Arab Emirates. This might be accomplished by recognition of unusual features in protein candidates. Phospholamban (PLB) is a 52 amino acid phosphoprotein which regulates the calcium pump of cardiac sarcoplasmic reticulum (SR). During muscle contraction, PLB inhibits the Ca++ pump. During muscle relaxation, it can be phosphorylated, removing the inhibition and allowing Ca++ to be pumped back into SR. With the calcium pump disrupted, the heart muscle is probably weakened, resulting in congestive heart failure. Interleukin 6 (IL-6) is considered as a better predictor of heart attack in elderly people. It could serve as an early warning sign since its level increases early in the inflammatory process. Also, it has been established that myocyte enhancer factor 2A (MEF2A) plays a vital role in the development of cardiovascular problems like atherosclerosis and restenosis after angioplasty inflammation. In this paper, the resonance recognition method (RRM) has been employed to determine the characteristic frequencies of the above-mentioned proteins. It has been found that phospholamban and IL-6 share the same characteristic frequency, 0.3320 plusmn 0.0002 suggesting their common probable contribution to heart failure. Myocyte enhancer factor 2A does not share the same characteristic frequency. Hence, phospholamban is suggested as a highly probable early marker for cardiac problem detection.

  6. Early Detection of Dyslexia in Children Act of 2009

    THOMAS, 111th Congress

    Rep. Jackson-Lee, Sheila [D-TX-18

    2009-01-06

    House - 03/16/2009 Referred to the Subcommittee on Early Childhood, Elementary, and Secondary Education. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  7. Early Damage Detection in Composites during Fabrication and Mechanical Testing

    PubMed Central

    Chandarana, Neha; Sanchez, Daniel Martinez; Soutis, Constantinos; Gresil, Matthieu

    2017-01-01

    Fully integrated monitoring systems have shown promise in improving confidence in composite materials while reducing lifecycle costs. A distributed optical fibre sensor is embedded in a fibre reinforced composite laminate, to give three sensing regions at different levels through-the-thickness of the plate. This study follows the resin infusion process during fabrication of the composite, monitoring the development of strain in-situ and in real time, and to gain better understanding of the resin rheology during curing. Piezoelectric wafer active sensors and electrical strain gauges are bonded to the plate after fabrication. This is followed by progressive loading/unloading cycles of mechanical four point bending. The strain values obtained from the optical fibre are in good agreement with strain data collected by surface mounted strain gauges, while the sensing regions clearly indicate the development of compressive, neutral, and tensile strain. Acoustic emission event detection suggests the formation of matrix (resin) cracks, with measured damage event amplitudes in agreement with values reported in published literature on the subject. The Felicity ratio for each subsequent loading cycle is calculated to track the progression of damage in the material. The methodology developed here can be used to follow the full life cycle of a composite structure, from manufacture to end-of-life. PMID:28773048

  8. Early Damage Detection in Composites during Fabrication and Mechanical Testing.

    PubMed

    Chandarana, Neha; Sanchez, Daniel Martinez; Soutis, Constantinos; Gresil, Matthieu

    2017-06-22

    Fully integrated monitoring systems have shown promise in improving confidence in composite materials while reducing lifecycle costs. A distributed optical fibre sensor is embedded in a fibre reinforced composite laminate, to give three sensing regions at different levels through-the-thickness of the plate. This study follows the resin infusion process during fabrication of the composite, monitoring the development of strain in-situ and in real time, and to gain better understanding of the resin rheology during curing. Piezoelectric wafer active sensors and electrical strain gauges are bonded to the plate after fabrication. This is followed by progressive loading/unloading cycles of mechanical four point bending. The strain values obtained from the optical fibre are in good agreement with strain data collected by surface mounted strain gauges, while the sensing regions clearly indicate the development of compressive, neutral, and tensile strain. Acoustic emission event detection suggests the formation of matrix (resin) cracks, with measured damage event amplitudes in agreement with values reported in published literature on the subject. The Felicity ratio for each subsequent loading cycle is calculated to track the progression of damage in the material. The methodology developed here can be used to follow the full life cycle of a composite structure, from manufacture to end-of-life.

  9. Modeling And Detecting Anomalies In Scada Systems

    NASA Astrophysics Data System (ADS)

    Svendsen, Nils; Wolthusen, Stephen

    The detection of attacks and intrusions based on anomalies is hampered by the limits of specificity underlying the detection techniques. However, in the case of many critical infrastructure systems, domain-specific knowledge and models can impose constraints that potentially reduce error rates. At the same time, attackers can use their knowledge of system behavior to mask their manipulations, causing adverse effects to observed only after a significant period of time. This paper describes elementary statistical techniques that can be applied to detect anomalies in critical infrastructure networks. A SCADA system employed in liquefied natural gas (LNG) production is used as a case study.

  10. Inertial navigation sensor integrated obstacle detection system

    NASA Technical Reports Server (NTRS)

    Bhanu, Bir (Inventor); Roberts, Barry A. (Inventor)

    1992-01-01

    A system that incorporates inertial sensor information into optical flow computations to detect obstacles and to provide alternative navigational paths free from obstacles. The system is a maximally passive obstacle detection system that makes selective use of an active sensor. The active detection typically utilizes a laser. Passive sensor suite includes binocular stereo, motion stereo and variable fields-of-view. Optical flow computations involve extraction, derotation and matching of interest points from sequential frames of imagery, for range interpolation of the sensed scene, which in turn provides obstacle information for purposes of safe navigation.

  11. Methods for Detecting Early Warnings of Critical Transitions in Time Series Illustrated Using Simulated Ecological Data

    PubMed Central

    Dakos, Vasilis; Carpenter, Stephen R.; Brock, William A.; Ellison, Aaron M.; Guttal, Vishwesha; Ives, Anthony R.; Kéfi, Sonia; Livina, Valerie; Seekell, David A.; van Nes, Egbert H.; Scheffer, Marten

    2012-01-01

    Many dynamical systems, including lakes, organisms, ocean circulation patterns, or financial markets, are now thought to have tipping points where critical transitions to a contrasting state can happen. Because critical transitions can occur unexpectedly and are difficult to manage, there is a need for methods that can be used to identify when a critical transition is approaching. Recent theory shows that we can identify the proximity of a system to a critical transition using a variety of so-called ‘early warning signals’, and successful empirical examples suggest a potential for practical applicability. However, while the range of proposed methods for predicting critical transitions is rapidly expanding, opinions on their practical use differ widely, and there is no comparative study that tests the limitations of the different methods to identify approaching critical transitions using time-series data. Here, we summarize a range of currently available early warning methods and apply them to two simulated time series that are typical of systems undergoing a critical transition. In addition to a methodological guide, our work offers a practical toolbox that may be used in a wide range of fields to help detect early warning signals of critical transitions in time series data. PMID:22815897

  12. Development of a GNSS-Enhanced Tsunami Early Warning System

    NASA Astrophysics Data System (ADS)

    Bawden, G. W.; Melbourne, T. I.; Bock, Y.; Song, Y. T.; Komjathy, A.

    2015-12-01

    The past decade has witnessed a terrible loss of life and economic disruption caused by large earthquakes and resultant tsunamis impacting coastal communities and infrastructure across the Indo-Pacific region. NASA has funded the early development of a prototype real-time Global Navigation Satellite System (RT-GNSS) based rapid earthquake and tsunami early warning (GNSS-TEW) system that may be used to enhance seismic tsunami early warning systems for large earthquakes. This prototype GNSS-TEW system geodetically estimates fault parameters (earthquake magnitude, location, strike, dip, and slip magnitude/direction on a gridded fault plane both along strike and at depth) and tsunami source parameters (seafloor displacement, tsunami energy scale, and 3D tsunami initials) within minutes after the mainshock based on dynamic numerical inversions/regressions of the real-time measured displacements within a spatially distributed real-time GNSS network(s) spanning the epicentral region. It is also possible to measure fluctuations in the ionosphere's total electron content (TEC) in the RT-GNSS data caused by the pressure wave from the tsunami. This TEC approach can detect if a tsunami has been triggered by an earthquake, track its waves as they propagate through the oceanic basins, and provide upwards of 45 minutes early warning. These combined real-time geodetic approaches will very quickly address a number of important questions in the immediate minutes following a major earthquake: How big was the earthquake and what are its fault parameters? Could the earthquake have produced a tsunami and was a tsunami generated?

  13. Early atmospheric detection of carbon dioxide from carbon capture and storage sites

    PubMed Central

    Pak, Nasrin Mostafavi; Rempillo, Ofelia; Norman, Ann-Lise; Layzell, David B.

    2016-01-01

    ABSTRACT The early atmospheric detection of carbon dioxide (CO2) leaks from carbon capture and storage (CCS) sites is important both to inform remediation efforts and to build and maintain public support for CCS in mitigating greenhouse gas emissions. A gas analysis system was developed to assess the origin of plumes of air enriched in CO2, as to whether CO2 is from a CCS site or from the oxidation of carbon compounds. The system measured CO2 and O2 concentrations for different plume samples relative to background air and calculated the gas differential concentration ratio (GDCR = −ΔO2/ΔCO2). The experimental results were in good agreement with theoretical calculations that placed GDCR values for a CO2 leak at 0.21, compared with GDCR values of 1–1.8 for the combustion of carbon compounds. Although some combustion plume samples deviated in GDCR from theoretical, the very low GDCR values associated with plumes from CO2 leaks provided confidence that this technology holds promise in providing a tool for the early detection of CO2 leaks from CCS sites.  Implications: This work contributes to the development of a cost-effective technology for the early detection of leaks from sites where CO2 has been injected into the subsurface to enhance oil recovery or to permanently store the gas as a strategy for mitigating climate change. Such technology will be important in building public confidence regarding the safety and security of carbon capture and storage sites. PMID:27111469

  14. Famine Early Warning System Network (FEWS NET)

    Verdin, James P.

    2006-01-01

    The FEWS NET mission is to identify potentially food-insecure conditions early through the provision of timely and analytical hazard and vulnerability information. U.S. Government decision-makers act on this information to authorize mitigation and response activities. The U.S. Geological Survey (USGS) FEWS NET provides tools and data for monitoring and forecasting the incidence of drought and flooding to identify shocks to the food supply system that could lead to famine. Historically focused on Africa, the scope of the network has expanded to be global coverage. FEWS NET implementing partners include the USGS, National Aeronautics and Space Administration (NASA), National Oceanic and Atmospheric Administration (NOAA), United States Agency for International Development (USAID), United States Department of Agriculture (USDA), and Chemonics International.

  15. Deep Water Munitions Detection System

    DTIC Science & Technology

    2010-03-01

    information if it does not display a currently valid OMB control number. 1. REPORT DATE MAR 2010 2. REPORT TYPE 3. DATES COVERED 00-00-2010 to 00-00...water systems to deeper water depths would result in even greater costs. While some of the cost escalation may be unavoidable, it is desirable to...magnetometers, spaced 61 cm apart, on a towed sensor platform. The sensor platform has active control elements that allow its depth to be changed

  16. Patient-Specific Early Seizure Detection from Scalp EEG

    PubMed Central

    Minasyan, Georgiy R.; Chatten, John B.; Chatten, Martha Jane; Harner, Richard N.

    2010-01-01

    Objective Develop a method for automatic detection of seizures prior to or immediately after clinical onset using features derived from scalp EEG. Methods This detection method is patient-specific. It uses recurrent neural networks and a variety of input features. For each patient we trained and optimized the detection algorithm for two cases: 1) during the period immediately preceding seizure onset, and 2) during the period immediately following seizure onset. Continuous scalp EEG recordings (duration 15 – 62 h, median 25 h) from 25 patients, including a total of 86 seizures, were used in this study. Results Pre-onset detection was successful in 14 of the 25 patients. For these 14 patients, all of the testing seizures were detected prior to seizure onset with a median pre-onset time of 51 sec and false positive rate was 0.06/h. Post-onset detection had 100% sensitivity, 0.023/hr false positive rate and median delay of 4 sec after onset. Conclusions The unique results of this study relate to pre-onset detection. Significance Our results suggest that reliable pre-onset seizure detection may be achievable for a significant subset of epilepsy patients without use of invasive electrodes. PMID:20461014

  17. [Chickenpox case estimation in acyclovir pharmacy survey and early bioterrorism detection].

    PubMed

    Sugawara, Tamie; Ohkusa, Yasushi; Kawanohara, Hirokazu; Taniguchi, Kiyosu; Okabe, Nobuhiko

    2011-11-01

    Early potential health hazards and bioterrorism threats require early detection. Smallpox cases caused by terrorist could, for example, be treated by prescribing acyclovir to those having fever and vesicle exanthema diagnosed as chicken pox. We have constructed real-time pharmacy surveillance scenarios using information technology (IT) to monitor acyclovir prescription. We collected the number of acyclovir prescriptions from 5138 pharmacies using the Application Server Provider System (ASP) to estimate the number of cases. We then compared the number of those given acyclovir under 15 years old from pharmacy surveillance and sentinel surveillance for chickenpox under the Infection Disease Control Law. The estimated number of under 15 years old prescribed acyclovir in pharmacy surveillance resembled sentinel surveillance results and showed a similar seasonal chickenpox pattern. The correlation coefficient was 0.8575. The estimated numbers of adults, older than 15 but under 65 years old, and elderly, older than 65, prescribed acyclovir showed no clear seasonal pattern. Pharmacy surveillance for acyclovir identified the baseline and can be used to detect unusual chickenpox outbreak. Bioterrorism attack could potentially be detected using smallpox virus when acyclovir prescription for adults suddenly increases without outbreaks in children or the elderly. This acyclovir prescription monitoring such as an application is, to our knowledge, the first of its kind anywhre.

  18. Photonic Crystal Enhanced Fluorescence for Early Breast Cancer Biomarker Detection

    PubMed Central

    Cunningham, Brian T.; Zangar, Richard C.

    2013-01-01

    Photonic crystal surfaces offer a compelling platform for improving the sensitivity of surface-based fluorescent assays used in disease diagnostics. Through the complementary processes of photonic crystal enhanced excitation and enhanced extraction, a periodic dielectric-based nanostructured surface can simultaneously increase the electric field intensity experienced by surface-bound fluorophores and increase the collection efficiency of emitted fluorescent photons. Through the ability to inexpensively fabricate photonic crystal surfaces over substantial surface areas, they are amenable to single-use applications in biological sensing, such as disease biomarker detection in serum. In this review, we will describe the motivation for implementing high-sensitivity, multiplexed biomarker detection in the context of breast cancer diagnosis. We will summarize recent efforts to improve the detection limits of such assays though the use of photonic crystal surfaces. Reduction of detection limits is driven by low autofluorescent substrates for photonic crystal fabrication, and detection instruments that take advantage of their unique features. PMID:22736539

  19. Early detection of schizophrenia: current evidence and future perspectives

    PubMed Central

    HÄFNER, HEINZ; MAURER, KURT

    2006-01-01

    Research into the early course of schizophrenia has identified a prepsychotic prodromal stage (mean duration: 4.8 years) and a psychotic prephase (mean duration: 1.3 years). Comparisons of individually matched samples have demonstrated prodromal symptoms common to schizophrenia and moderate to severe depression. It is not until positive symptoms emerge that psychosis and mood disorders become distinguishable from each other. In both disorders the prodromal stage early produces functional impairment and related social consequences. Hence, early intervention is of great public health relevance. This intervention is targeted at manifest symptoms and not at the underlying, still unknown disease process. Cognitive-behavioural therapy at the prepsychotic prodromal stage seems to favourably influence the short-term illness course. In the psychotic prephase, a combination with low-dose antipsychotics seems to have some efficacy. The aim of early recognition by the instruments discussed in this paper is to permit the identification of the largest possible proportion of at-risk persons as early as possible and their referral to appropriate treatment. PMID:17139339

  20. Detection of retinal nerve fiber layer defects on retinal fundus images for early diagnosis of glaucoma

    NASA Astrophysics Data System (ADS)

    Muramatsu, Chisako; Hayashi, Yoshinori; Sawada, Akira; Hatanaka, Yuji; Hara, Takeshi; Yamamoto, Tetsuya; Fujita, Hiroshi

    2010-01-01

    Retinal nerve fiber layer defect (NFLD) is a major sign of glaucoma, which is the second leading cause of blindness in the world. Early detection of NFLDs is critical for improved prognosis of this progressive, blinding disease. We have investigated a computerized scheme for detection of NFLDs on retinal fundus images. In this study, 162 images, including 81 images with 99 NFLDs, were used. After major blood vessels were removed, the images were transformed so that the curved paths of retinal nerves become approximately straight on the basis of ellipses, and the Gabor filters were applied for enhancement of NFLDs. Bandlike regions darker than the surrounding pixels were detected as candidates of NFLDs. For each candidate, image features were determined and the likelihood of a true NFLD was determined by using the linear discriminant analysis and an artificial neural network (ANN). The sensitivity for detecting the NFLDs was 91% at 1.0 false positive per image by using the ANN. The proposed computerized system for the detection of NFLDs can be useful to physicians in the diagnosis of glaucoma in a mass screening.

  1. Neuroimaging parameters in early open spina bifida detection. Further benefit in first trimester screening?

    PubMed

    Iliescu, D; Comănescu, A; Antsaklis, P; Tudorache, Stefania; Ghiluşi, Mirela; Comănescu, Violeta; Paulescu, Daniela; Ceauşu, Iuliana; Antsaklis, A; Novac, Liliana; Cernea, N

    2011-01-01

    Morphological investigation of the central nervous system (CNS) in fetuses with positive markers for open spina bifida (OSB) detection, visualized by ultrasound during the first trimester of pregnancy. Data from fetuses that underwent routine first trimester ultrasound scan in our center during September 2007-March 2011 and presented abnormal aspects of the fourth ventricle, also referred as intracranial translucency (IT), provided the morphological support to evaluate CNS features. A neuro-histological study of posterior cerebral fossa illustrated anatomical features of the structures involved in the sonographic first trimester detection of neural tube defects. Abnormal IT aspects were found in OSB cases examined in the first trimester, but also in other severe cerebral abnormalities. Brain stem antero-posterior diameter (BS) and brain stem to occipital bone (BSOB) ratio may be more specific for OSB detection. Correlations between histological aspects of posterior brain fossa and ultrasound standard assessment have been made; highlighting the anatomical features involved by the new techniques developed for OSB early detection. Preliminary results show that modern sonographic protocols are capable to detect abnormalities in the morphometry of the posterior brain. First trimester fourth ventricle abnormalities should be followed by careful CNS evaluation because are likely to appear in OSB affected fetuses, but also in other CNS severe anomalies; in such cases, normal BS and BSOB ratio may serve as indirect argument for spine integrity, if specificity is confirmed in large series of fetuses.

  2. [Development of operation patient security detection system].

    PubMed

    Geng, Shu-Qin; Tao, Ren-Hai; Zhao, Chao; Wei, Qun

    2008-11-01

    This paper describes a patient security detection system developed with two dimensional bar codes, wireless communication and removal storage technique. Based on the system, nurses and correlative personnel check code wait operation patient to prevent the defaults. The tests show the system is effective. Its objectivity and currency are more scientific and sophisticated than current traditional method in domestic hospital.

  3. RADIATION DETECTING AND TELEMETERING SYSTEM

    DOEpatents

    Richards, H.K.

    1959-12-15

    A system is presented for measuring ionizing radiation at several remote stations and transmitting the measured information by radio to a central station. At each remote station a signal proportioned to the counting rate is applied across an electrical condenser made of ferroelectric material. The voltage across the condenser will vary as a function of the incident radiation and the capacitance of the condenser will vary accordingly. This change in capacitance is used to change the frequency of a crystalcontrolled oscillator. The output of the oscillator is coupled to an antenna for transmitting a signal proportional to the incident radiation.

  4. Improvements in diagnostic tools for early detection of psoriatic arthritis.

    PubMed

    D'Angelo, Salvatore; Palazzi, Carlo; Gilio, Michele; Leccese, Pietro; Padula, Angela; Olivieri, Ignazio

    2016-11-01

    Psoriatic arthritis (PsA) is a heterogeneous chronic inflammatory disease characterized by a wide clinical spectrum. The early diagnosis of PsA is currently a challenging topic. Areas covered: The literature was extensively reviewed for studies addressing the topic area "diagnosis of psoriatic arthritis". This review will summarize improvements in diagnostic tools, especially referral to the rheumatologist, the role of patient history and clinical examination, laboratory tests, and imaging techniques in getting an early and correct diagnosis of PsA. Expert commentary: Due to the heterogeneity of its expression, PsA may be easily either overdiagnosed or underdiagnosed. A diagnosis of PsA should be taken into account every time a patient with psoriasis or a family history of psoriasis shows peripheral arthritis, especially if oligoarticular or involving the distal interphalangeal joints, enthesitis or dactylitis. Magnetic resonance imaging and ultrasonography are useful for diagnosing PsA early, particularly when isolated enthesitis or inflammatory spinal pain occur.

  5. Real-Time Detection of Rupture Development: Earthquake Early Warning Using P Waves From Growing Ruptures

    NASA Astrophysics Data System (ADS)

    Kodera, Yuki

    2018-01-01

    Large earthquakes with long rupture durations emit P wave energy throughout the rupture period. Incorporating late-onset P waves into earthquake early warning (EEW) algorithms could contribute to robust predictions of strong ground motion. Here I describe a technique to detect in real time P waves from growing ruptures to improve the timeliness of an EEW algorithm based on seismic wavefield estimation. The proposed P wave detector, which employs a simple polarization analysis, successfully detected P waves from strong motion generation areas of the 2011 Mw 9.0 Tohoku-oki earthquake rupture. An analysis using 23 large (M ≥ 7) events from Japan confirmed that seismic intensity predictions based on the P wave detector significantly increased lead times without appreciably decreasing the prediction accuracy. P waves from growing ruptures, being one of the fastest carriers of information on ongoing rupture development, have the potential to improve the performance of EEW systems.

  6. Caltrans fog detection and warning system.

    DOT National Transportation Integrated Search

    2009-01-01

    The California Department of Transportation (Caltrans) has implemented a fog detection and warning system on Highway 99 near Fresno. The entire central valley region is susceptible to Tule fog, which can reduce visibility tremendously, sometimes to n...

  7. Fail-safe fire detection system

    NASA Technical Reports Server (NTRS)

    Bloam, E. T.

    1974-01-01

    Fire detection control system continually monitors its own integrity, automatically signals any malfunction, and separately signals fire in any zone being monitored. Should be of interest in fields of chemical and petroleum processing, power generation, equipment testing, and building protection.

  8. Computer systems for automatic earthquake detection

    Stewart, S.W.

    1974-01-01

    U.S Geological Survey seismologists in Menlo park, California, are utilizing the speed, reliability, and efficiency of minicomputers to monitor seismograph stations and to automatically detect earthquakes. An earthquake detection computer system, believed to be the only one of its kind in operation, automatically reports about 90 percent of all local earthquakes recorded by a network of over 100 central California seismograph stations. The system also monitors the stations for signs of malfunction or abnormal operation. Before the automatic system was put in operation, all of the earthquakes recorded had to be detected by manually searching the records, a time-consuming process. With the automatic detection system, the stations are efficiently monitored continuously. 

  9. GPS water level measurements for Indonesia's Tsunami Early Warning System

    NASA Astrophysics Data System (ADS)

    Schöne, T.; Pandoe, W.; Mudita, I.; Roemer, S.; Illigner, J.; Zech, C.; Galas, R.

    2011-03-01

    On Boxing Day 2004, a severe tsunami was generated by a strong earthquake in Northern Sumatra causing a large number of casualties. At this time, neither an offshore buoy network was in place to measure tsunami waves, nor a system to disseminate tsunami warnings to local governmental entities. Since then, buoys have been developed by Indonesia and Germany, complemented by NOAA's Deep-ocean Assessment and Reporting of Tsunamis (DART) buoys, and have been moored offshore Sumatra and Java. The suite of sensors for offshore tsunami detection in Indonesia has been advanced by adding GPS technology for water level measurements. The usage of GPS buoys in tsunami warning systems is a relatively new approach. The concept of the German Indonesian Tsunami Early Warning System (GITEWS) (Rudloff et al., 2009) combines GPS technology and ocean bottom pressure (OBP) measurements. Especially for near-field installations where the seismic noise may deteriorate the OBP data, GPS-derived sea level heights provide additional information. The GPS buoy technology is precise enough to detect medium to large tsunamis of amplitudes larger than 10 cm. The analysis presented here suggests that for about 68% of the time, tsunamis larger than 5 cm may be detectable.

  10. Early identification of microorganisms in blood culture prior to the detection of a positive signal in the BACTEC FX system using matrix-assisted laser desorption/ionization-time of flight mass spectrometry.

    PubMed

    Wang, Ming-Cheng; Lin, Wei-Hung; Yan, Jing-Jou; Fang, Hsin-Yi; Kuo, Te-Hui; Tseng, Chin-Chung; Wu, Jiunn-Jong

    2015-08-01

    Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) is a valuable method for rapid identification of blood stream infection (BSI) pathogens. Integration of MALDI-TOF MS and blood culture system can speed the identification of causative BSI microorganisms. We investigated the minimal microorganism concentrations of common BSI pathogens required for positive blood culture using BACTEC FX and for positive identification using MALDI-TOF MS. The time to detection with positive BACTEC FX and minimal incubation time with positive MALDI-TOF MS identification were determined for earlier identification of common BSI pathogens. The minimal microorganism concentrations required for positive blood culture using BACTEC FX were >10(7)-10(8) colony forming units/mL for most of the BSI pathogens. The minimal microorganism concentrations required for identification using MALDI-TOF MS were > 10(7) colony forming units/mL. Using simulated BSI models, one can obtain enough bacterial concentration from blood culture bottles for successful identification of five common Gram-positive and Gram-negative bacteria using MALDI-TOF MS 1.7-2.3 hours earlier than the usual time to detection in blood culture systems. This study provides an approach to earlier identification of BSI pathogens prior to the detection of a positive signal in the blood culture system using MALDI-TOF MS, compared to current methods. It can speed the time for identification of BSI pathogens and may have benefits of earlier therapy choice and on patient outcome. Copyright © 2013. Published by Elsevier B.V.

  11. Heartbeat detection system using piezoelectric transducer

    NASA Astrophysics Data System (ADS)

    Hamonangan, Yosua; Purnamaningsih, Wigajatri

    2017-02-01

    This paper presents a simple piezoelectric based heartbeat detection system. The signal produced by the piezoelectric will undergo signal conditioning and then converted into digital data by Arduino Nano. Using serial communication, the data will be sent to a computer for display and further analysis. The detection of heartbeat is carried out on three locations; wrist, chest, and diaphragm. From the measurement results, it is shown that the system work best when the piezoelectric is placed on wrist.

  12. Multispectral imaging system for contaminant detection

    NASA Technical Reports Server (NTRS)

    Poole, Gavin H. (Inventor)

    2003-01-01

    An automated inspection system for detecting digestive contaminants on food items as they are being processed for consumption includes a conveyor for transporting the food items, a light sealed enclosure which surrounds a portion of the conveyor, with a light source and a multispectral or hyperspectral digital imaging camera disposed within the enclosure. Operation of the conveyor, light source and camera are controlled by a central computer unit. Light reflected by the food items within the enclosure is detected in predetermined wavelength bands, and detected intensity values are analyzed to detect the presence of digestive contamination.

  13. National program of breast cancer early detection in Brod-Posavina County (East Croatia).

    PubMed

    Jurišić, Irena; Kolovrat, Ana; Mitrečić, Drago; Cvitković, Ante

    2014-09-01

    Results of the National Program of Breast Cancer Early Detection in Brod-Posavina County during the 2006-2012 period are presented. Response rate in two National Program cycles, cancers detected according to factors such as first and last menstruation, age at cancer detection, deliveries and mammography findings according to the Breast Imaging Reporting and Data System (BI-RADS) before diagnosis verification were analyzed. Data were obtained from the software connecting Public Health Institutes via Ministry of Health server and questionnaires filled out by the women presenting for screening and processed by the method of descriptive statistics. Mammography findings were classified according to the BI-RADS classification. In two National Program cycles during the 2006-2012 period, women aged 50-69 were called for mammography screening. In the first cycle, the response rate in Brod-Posavina County was 53.2%, with 71 cancers detected at a mean age of 61.3 years. In the second cycle, the response rate was 57.0%, with 44 cancers detected at a mean age of 62.5 years. In the first and second cycles, there were 21.1% and 14.3% of mammography findings requiring additional work-up (BI-RADS 0), respectively. Particular risk factors such as early menarche, late menopause, parity, positive family history and presence of benign breast lesions were not demonstrated in women with verified cancer. There was no increase in the incidence of breast cancer per 100,000 inhabitants in the Brod-Posavina County following implementation of the National Program. In conclusion, efforts should be focused on increasing public health awareness, ensuring appropriate professional staff engaged in screening, and improving medical care in order to reduce the time elapsed from establishing suspicion to confirming the diagnosis of breast cancer.

  14. Detection limit used for early warning in public health surveillance.

    PubMed

    Kobari, Tsuyoshi; Iwaki, Kazuo; Nagashima, Tomomi; Ishii, Fumiyoshi; Hayashi, Yuzuru; Yajima, Takehiko

    2009-06-01

    A theory of detection limit, developed in analytical chemistry, is applied to public health surveillance to detect an outbreak of national emergencies such as natural disaster and bioterrorism. In this investigation, the influenza epidemic around the Tokyo area from 2003 to 2006 is taken as a model of normal and large-scale epidemics. The detection limit of the normal epidemic is used as a threshold with a specified level of significance to identify a sign of the abnormal epidemic among the daily variation in anti-influenza drug sales at community pharmacies. While auto-correlation of data is often an obstacle to an unbiased estimator of standard deviation involved in the detection limit, the analytical theory (FUMI) can successfully treat the auto-correlation of the drug sales in the same way as the auto-correlation appearing as 1/f noise in many analytical instruments.

  15. Early Detection of NSCLC Using Stromal Markers in Peripheral Blood

    DTIC Science & Technology

    2017-11-01

    transcriptionally altered and the alteration is tumor dependent . The specific transcriptomic signature of circulating myeloid cells may provide us unique...signature, which may be useful for early lung cancer diagnosis. The specific aims are: Aim 1. To identify a NSCLC- dependent transcriptomic signature in...circulating myeloid cells are transcriptionally altered and the alteration is tumor dependent . The specific transcriptomic signature of circulating

  16. Airborne Turbulence Detection System Certification Tool Set

    NASA Technical Reports Server (NTRS)

    Hamilton, David W.; Proctor, Fred H.

    2006-01-01

    A methodology and a corresponding set of simulation tools for testing and evaluating turbulence detection sensors has been presented. The tool set is available to industry and the FAA for certification of radar based airborne turbulence detection systems. The tool set consists of simulated data sets representing convectively induced turbulence, an airborne radar simulation system, hazard tables to convert the radar observable to an aircraft load, documentation, a hazard metric "truth" algorithm, and criteria for scoring the predictions. Analysis indicates that flight test data supports spatial buffers for scoring detections. Also, flight data and demonstrations with the tool set suggest the need for a magnitude buffer.

  17. Peptide synthesis in early earth hydrothermal systems

    Lemke, K.H.; Rosenbauer, R.J.; Bird, D.K.

    2009-01-01

    We report here results from experiments and thermodynamic calculations that demonstrate a rapid, temperature-enhanced synthesis of oligopeptides from the condensation of aqueous glycine. Experiments were conducted in custom-made hydrothermal reactors, and organic compounds were characterized with ultraviolet-visible procedures. A comparison of peptide yields at 260??C with those obtained at more moderate temperatures (160??C) gives evidence of a significant (13 kJ ?? mol-1) exergonic shift. In contrast to previous hydrothermal studies, we demonstrate that peptide synthesis is favored in hydrothermal fluids and that rates of peptide hydrolysis are controlled by the stability of the parent amino acid, with a critical dependence on reactor surface composition. From our study, we predict that rapid recycling of product peptides from cool into near-supercritical fluids in mid-ocean ridge hydrothermal systems will enhance peptide chain elongation. It is anticipated that the abundant hydrothermal systems on early Earth could have provided a substantial source of biomolecules required for the origin of life. Astrobiology 9, 141-146. ?? 2009 Mary Ann Liebert, Inc. 2009.

  18. Design and validation of a near-infrared fluorescence endoscope for detection of early esophageal malignancy

    NASA Astrophysics Data System (ADS)

    Waterhouse, Dale J.; Joseph, James; Neves, André A.; di Pietro, Massimiliano; Brindle, Kevin M.; Fitzgerald, Rebecca C.; Bohndiek, Sarah E.

    2016-08-01

    Barrett's esophagus is a known precursor lesion to esophageal adenocarcinoma. In these patients, early detection of premalignant disease, known as dysplasia, allows curative minimally invasive endoscopic therapy, but is confounded by a lack of contrast in white light endoscopy. Imaging fluorescently labeled lectins applied topically to the tissue has the potential to more accurately delineate dysplasia, but tissue autofluorescence limits both sensitivity and contrast when operating in the visible region. To overcome this challenge, we synthesized near-infrared (NIR) fluorescent wheat germ agglutinin (WGA-IR800CW) and constructed a clinically translatable bimodal NIR and white light endoscope. Images of NIR and white light with a field of view of 63 deg and an image resolution of 182 μm are coregistered and the honeycomb artifact arising from the fiber bundle is removed. A minimum detectable concentration of 110 nM was determined using a dilution series of WGA-IR800CW. We demonstrated ex vivo that this system can distinguish between gastric and squamous tissue types in mouse stomachs (p=0.0005) and accurately detect WGA-IR800CW fluorescence in human esophageal resections (compared with a gold standard imaging system, rs>0.90). Based on these findings, future work will optimize the bimodal endoscopic system for clinical trials in Barrett's surveillance.

  19. Vision-Based Sensor for Early Detection of Periodical Defects in Web Materials

    PubMed Central

    Bulnes, Francisco G.; Usamentiaga, Rubén; García, Daniel F.; Molleda, Julio

    2012-01-01

    During the production of web materials such as plastic, textiles or metal, where there are rolls involved in the production process, periodically generated defects may occur. If one of these rolls has some kind of flaw, it can generate a defect on the material surface each time it completes a full turn. This can cause the generation of a large number of surface defects, greatly degrading the product quality. For this reason, it is necessary to have a system that can detect these situations as soon as possible. This paper presents a vision-based sensor for the early detection of this kind of defects. It can be adapted to be used in the inspection of any web material, even when the input data are very noisy. To assess its performance, the sensor system was used to detect periodical defects in hot steel strips. A total of 36 strips produced in ArcelorMittal Avilés factory were used for this purpose, 18 to determine the optimal configuration of the proposed sensor using a full-factorial experimental design and the other 18 to verify the validity of the results. Next, they were compared with those provided by a commercial system used worldwide, showing a clear improvement. PMID:23112629

  20. Flat Surface Damage Detection System (FSDDS)

    NASA Technical Reports Server (NTRS)

    Williams, Martha; Lewis, Mark; Gibson, Tracy; Lane, John; Medelius, Pedro; Snyder, Sarah; Ciarlariello, Dan; Parks, Steve; Carrejo, Danny; Rojdev, Kristina

    2013-01-01

    The Flat Surface Damage Detection system (FSDDS} is a sensory system that is capable of detecting impact damages to surfaces utilizing a novel sensor system. This system will provide the ability to monitor the integrity of an inflatable habitat during in situ system health monitoring. The system consists of three main custom designed subsystems: the multi-layer sensing panel, the embedded monitoring system, and the graphical user interface (GUI). The GUI LABVIEW software uses a custom developed damage detection algorithm to determine the damage location based on the sequence of broken sensing lines. It estimates the damage size, the maximum depth, and plots the damage location on a graph. Successfully demonstrated as a stand alone technology during 2011 D-RATS. Software modification also allowed for communication with HDU avionics crew display which was demonstrated remotely (KSC to JSC} during 2012 integration testing. Integrated FSDDS system and stand alone multi-panel systems were demonstrated remotely and at JSC, Mission Operations Test using Space Network Research Federation (SNRF} network in 2012. FY13, FSDDS multi-panel integration with JSC and SNRF network Technology can allow for integration with other complementary damage detection systems.

  1. Automated Hydrogen Gas Leak Detection System

    NASA Technical Reports Server (NTRS)

    1995-01-01

    The Gencorp Aerojet Automated Hydrogen Gas Leak Detection System was developed through the cooperation of industry, academia, and the Government. Although the original purpose of the system was to detect leaks in the main engine of the space shuttle while on the launch pad, it also has significant commercial potential in applications for which there are no existing commercial systems. With high sensitivity, the system can detect hydrogen leaks at low concentrations in inert environments. The sensors are integrated with hardware and software to form a complete system. Several of these systems have already been purchased for use on the Ford Motor Company assembly line for natural gas vehicles. This system to detect trace hydrogen gas leaks from pressurized systems consists of a microprocessor-based control unit that operates a network of sensors. The sensors can be deployed around pipes, connectors, flanges, and tanks of pressurized systems where leaks may occur. The control unit monitors the sensors and provides the operator with a visual representation of the magnitude and locations of the leak as a function of time. The system can be customized to fit the user's needs; for example, it can monitor and display the condition of the flanges and fittings associated with the tank of a natural gas vehicle.

  2. Sensor Failure Detection of FASSIP System using Principal Component Analysis

    NASA Astrophysics Data System (ADS)

    Sudarno; Juarsa, Mulya; Santosa, Kussigit; Deswandri; Sunaryo, Geni Rina

    2018-02-01

    In the nuclear reactor accident of Fukushima Daiichi in Japan, the damages of core and pressure vessel were caused by the failure of its active cooling system (diesel generator was inundated by tsunami). Thus researches on passive cooling system for Nuclear Power Plant are performed to improve the safety aspects of nuclear reactors. The FASSIP system (Passive System Simulation Facility) is an installation used to study the characteristics of passive cooling systems at nuclear power plants. The accuracy of sensor measurement of FASSIP system is essential, because as the basis for determining the characteristics of a passive cooling system. In this research, a sensor failure detection method for FASSIP system is developed, so the indication of sensor failures can be detected early. The method used is Principal Component Analysis (PCA) to reduce the dimension of the sensor, with the Squarred Prediction Error (SPE) and statistic Hotteling criteria for detecting sensor failure indication. The results shows that PCA method is capable to detect the occurrence of a failure at any sensor.

  3. Early Detection of Amyloid Plaque in Alzheimer’s Disease via X-ray Phase CT

    DTIC Science & Technology

    2016-08-01

    AWARD NUMBER: W81XWH-12-1-0138 TITLE: Early Detection of Amyloid Plaque in Alzheimer’s Disease via X-ray Phase CT PRINCIPAL INVESTIGATOR...NUMBER W81XWH-12-1-0138 Early Detection of Amyloid Plaque in Alzheimer’s Disease via X-ray Phase CT 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...method for early detection of amyloid plaque in Alzheimer’s disease , with three Specific Aims: #1 Develop and optimize an x-ray PCCT to explore the

  4. Detection probability of EBPSK-MODEM system

    NASA Astrophysics Data System (ADS)

    Yao, Yu; Wu, Lenan

    2016-07-01

    Since the impacting filter-based receiver is able to transform phase modulation into amplitude peak, a simple threshold decision can detect the Extend-Binary Phase Shift Keying (EBPSK) modulated ranging signal in noise environment. In this paper, an analysis of the EBPSK-MODEM system output gives the probability density function for EBPSK modulated signals plus noise. The equation of detection probability (pd) for fluctuating and non-fluctuating targets has been deduced. Also, a comparison of the pd for the EBPSK-MODEM system and pulse radar receiver is made, and some results are plotted. Moreover, the probability curves of such system with several modulation parameters are analysed. When modulation parameter is not smaller than 6, the detection performance of EBPSK-MODEM system is more excellent than traditional radar system. In addition to theoretical considerations, computer simulations are provided for illustrating the performance.

  5. Autonomous microfluidic system for phosphate detection.

    PubMed

    McGraw, Christina M; Stitzel, Shannon E; Cleary, John; Slater, Conor; Diamond, Dermot

    2007-02-28

    Miniaturization of analytical devices through the advent of microfluidics and micro total analysis systems is an important step forward for applications such as medical diagnostics and environmental monitoring. The development of field-deployable instruments requires that the entire system, including all necessary peripheral components, be miniaturized and packaged in a portable device. A sensor for long-term monitoring of phosphate levels has been developed that incorporates sampling, reagent and waste storage, detection, and wireless communication into a complete, miniaturized system. The device employs a low-power detection and communication system, so the entire instrument can operate autonomously for 7 days on a single rechargeable, 12V battery. In addition, integration of a wireless communication device allows the instrument to be controlled and results to be downloaded remotely. This autonomous system has a limit of detection of 0.3mg/L and a linear dynamic range between 0 and 20mg/L.

  6. Leveraging biospecimen resources for discovery or validation of markers for early cancer detection.

    PubMed

    Schully, Sheri D; Carrick, Danielle M; Mechanic, Leah E; Srivastava, Sudhir; Anderson, Garnet L; Baron, John A; Berg, Christine D; Cullen, Jennifer; Diamandis, Eleftherios P; Doria-Rose, V Paul; Goddard, Katrina A B; Hankinson, Susan E; Kushi, Lawrence H; Larson, Eric B; McShane, Lisa M; Schilsky, Richard L; Shak, Steven; Skates, Steven J; Urban, Nicole; Kramer, Barnett S; Khoury, Muin J; Ransohoff, David F

    2015-04-01

    Validation of early detection cancer biomarkers has proven to be disappointing when initial promising claims have often not been reproducible in diagnostic samples or did not extend to prediagnostic samples. The previously reported lack of rigorous internal validity (systematic differences between compared groups) and external validity (lack of generalizability beyond compared groups) may be effectively addressed by utilizing blood specimens and data collected within well-conducted cohort studies. Cohort studies with prediagnostic specimens (eg, blood specimens collected prior to development of clinical symptoms) and clinical data have recently been used to assess the validity of some early detection biomarkers. With this background, the Division of Cancer Control and Population Sciences (DCCPS) and the Division of Cancer Prevention (DCP) of the National Cancer Institute (NCI) held a joint workshop in August 2013. The goal was to advance early detection cancer research by considering how the infrastructure of cohort studies that already exist or are being developed might be leveraged to include appropriate blood specimens, including prediagnostic specimens, ideally collected at periodic intervals, along with clinical data about symptom status and cancer diagnosis. Three overarching recommendations emerged from the discussions: 1) facilitate sharing of existing specimens and data, 2) encourage collaboration among scientists developing biomarkers and those conducting observational cohort studies or managing healthcare systems with cohorts followed over time, and 3) conduct pilot projects that identify and address key logistic and feasibility issues regarding how appropriate specimens and clinical data might be collected at reasonable effort and cost within existing or future cohorts. © Published by Oxford University Press 2015.

  7. Call for research: detecting early vulnerability for psychiatric hospitalization.

    PubMed

    Prince, Jonathan D

    2013-01-01

    This study delineated the extent to which a broad set of risk factors in youth, a period well suited to primary prevention strategies, influences the likelihood and timing of first lifetime psychiatric hospitalizations. Logistic regression was used to delineate early risk factors for psychiatric hospitalization among Americans in a nationally representative survey (NCS-R, Part II, 2001-2003: N = 5,692). Results suggest that inpatient stay is more common and happens at earlier ages among Americans who report growing up with versus without: (1) depressed parents or caregivers, (2) family members who victimized them, or (3) one of three child mental illnesses (conduct, oppositional defiant, or separation anxiety disorder). In order to prevent inpatient stay, findings call for longitudinal research on early vulnerability for psychiatric hospitalization among families with: (1) depressed parents of children or adolescents, (2) violence against children, and (3) children that have externalizing or separation anxiety disorders.

  8. The biospeckle method for early damage detection of fruits

    NASA Astrophysics Data System (ADS)

    Yan, Lei; Liu, Jiaxin; Men, Sen

    2017-07-01

    In the field of fruits damage assessment, biospeckle activity is considered relevant to quality properties of plants, such us damage, aging, or diseases. In this paper, biospeckle technique was applied to identify the early bruising of apples. Then a total of 50 undamaged apples were determined to be artificially bruised as samples. Three methods (Fujii, GD, and LSTCA) were used to extract effective information from these speckle images for measuring the intensity of biospeckle activity. The results showed that for all of three methods, the biospeckle activities of the undamaged areas in apple were similar; after the hit, the damaged area showed a lower biospeckle activity. It can be concluded that early bruising can be identified by biospeckle technique.

  9. Combined Screening for Early Detection of Pre-Eclampsia

    PubMed Central

    Park, Hee Jin; Shim, Sung Shin; Cha, Dong Hyun

    2015-01-01

    Although the precise pathophysiology of pre-eclampsia remains unknown, this condition continues to be a major cause of maternal and fetal mortality. Early prediction of pre-eclampsia would allow for timely initiation of preventive therapy. A combination of biophysical and biochemical markers are superior to other tests for early prediction of the development of pre-eclampsia. Apart from the use of parameters in first-trimester aneuploidy screening, cell-free fetal DNA quantification is emerging as a promising marker for prediction of pre-eclampsia. This article reviews the current research of the most important strategies for prediction of pre-eclampsia, including the use of maternal risk factors, mean maternal arterial pressure, ultrasound parameters, and biomarkers. PMID:26247944

  10. Strategies for early melanoma detection: approaches to the patient with nevi

    PubMed Central

    Goodson, Agnessa G.; Grossman, Douglas

    2009-01-01

    Given its propensity to metastasize, and lack of effective therapies for most patients with advanced disease, early detection of melanoma is a clinical imperative. Although there are no non-invasive techniques for definitive diagnosis of melanoma, and the “gold standard” remains biopsy with histologic examination, a variety of modalities may facilitate early melanoma diagnosis and the detection of new and changing nevi. This article reviews general clinical principles of early melanoma detection, and various modalities that are currently available or on the horizon, providing the clinician with an up-to-date understanding of management strategies for their patients with numerous or atypical nevi. Learning objectives At the conclusion of this learning activity, participants should: 1) understand the clinical importance of early melanoma detection; 2) appreciate the challenges of early melanoma diagnosis and which patients are at highest risk; 3) know general principles of early melanoma detection; 4) be familiar with current and emerging modalities that may facilitate early melanoma diagnosis and the detection of new and changing nevi; 5) know the advantages and limitations of each modality; and 6) be able to practice a combined approach to the patient with numerous or clinically atypical nevi. PMID:19389517

  11. Triple diagnostics for early detection of ambivalent necrotizing fasciitis.

    PubMed

    Hietbrink, Falco; Bode, Lonneke G; Riddez, Louis; Leenen, Luke P H; van Dijk, Marijke R

    2016-01-01

    Necrotizing fasciitis is an uncommon, rapidly progressive and potential lethal condition. Over the last decade time to surgery decreased and outcome improved, most likely due to increased awareness and more timely referral. Early recognition is key to improve mortality and morbidity. However, early referral frequently makes it a challenge to recognize this heterogeneous disease in its initial stages. Signs and symptoms might be misleading or absent, while the most prominent skin marks might be in discrepancy with the position of the fascial necrosis. Gram staining and especially fresh frozen section histology might be a useful adjunct. Retrospective analysis of 3 year period. Non-transferred patients who presented with suspected necrotizing fasciitis are included. ASA classification was determined. Mortality was documented. In total, 21 patients are included. Most patients suffered from severe comorbidities. In 11 patients, diagnoses was confirmed based on intra-operative macroscopic findings. Histology and/or microbiotic findings resulted in 6/10 remaining patients in a change in treatment strategy. In total, 17 patients proved to suffer necrotizing fasciitis. In the cohort series 2 patients died due to necrotizing fasciitis. In the early phases of necrotizing fasciitis, clinical presentation can be ambivalent. In the present cohort, triple diagnostics consisting of an incisional biopsy with macroscopic, histologic and microbiotic findings was helpful in timely identification of necrotizing fasciitis.

  12. A system for distributed intrusion detection

    SciT

    Snapp, S.R.; Brentano, J.; Dias, G.V.

    1991-01-01

    The study of providing security in computer networks is a rapidly growing area of interest because the network is the medium over which most attacks or intrusions on computer systems are launched. One approach to solving this problem is the intrusion-detection concept, whose basic premise is that not only abandoning the existing and huge infrastructure of possibly-insecure computer and network systems is impossible, but also replacing them by totally-secure systems may not be feasible or cost effective. Previous work on intrusion-detection systems were performed on stand-alone hosts and on a broadcast local area network (LAN) environment. The focus of ourmore » present research is to extend our network intrusion-detection concept from the LAN environment to arbitarily wider areas with the network topology being arbitrary as well. The generalized distributed environment is heterogeneous, i.e., the network nodes can be hosts or servers from different vendors, or some of them could be LAN managers, like our previous work, a network security monitor (NSM), as well. The proposed architecture for this distributed intrusion-detection system consists of the following components: a host manager in each host; a LAN manager for monitoring each LAN in the system; and a central manager which is placed at a single secure location and which receives reports from various host and LAN managers to process these reports, correlate them, and detect intrusions. 11 refs., 2 figs.« less

  13. Capacitive system detects and locates fluid leaks

    NASA Technical Reports Server (NTRS)

    1966-01-01

    Electronic monitoring system automatically detects and locates minute leaks in seams of large fluid storage tanks and pipelines covered with thermal insulation. The system uses a capacitive tape-sensing element that is adhesively bonded over seams where fluid leaks are likely to occur.

  14. Expert System Detects Power-Distribution Faults

    NASA Technical Reports Server (NTRS)

    Walters, Jerry L.; Quinn, Todd M.

    1994-01-01

    Autonomous Power Expert (APEX) computer program is prototype expert-system program detecting faults in electrical-power-distribution system. Assists human operators in diagnosing faults and deciding what adjustments or repairs needed for immediate recovery from faults or for maintenance to correct initially nonthreatening conditions that could develop into faults. Written in Lisp.

  15. Field Evaluation of Detection-Control System

    DOT National Transportation Integrated Search

    2015-04-01

    In this research, a field evaluation of the Detection-Control System (D-CS) was conducted at eight sites located in four States. D-CS is similar to a traditional advance detector system in that it uses information from detectors located upstream of t...

  16. Advanced Atmospheric Water Vapor DIAL Detection System

    NASA Technical Reports Server (NTRS)

    Refaat, Tamer F.; Elsayed-Ali, Hani E.; DeYoung, Russell J. (Technical Monitor)

    2000-01-01

    Measurement of atmospheric water vapor is very important for understanding the Earth's climate and water cycle. The remote sensing Differential Absorption Lidar (DIAL) technique is a powerful method to perform such measurement from aircraft and space. This thesis describes a new advanced detection system, which incorporates major improvements regarding sensitivity and size. These improvements include a low noise advanced avalanche photodiode detector, a custom analog circuit, a 14-bit digitizer, a microcontroller for on board averaging and finally a fast computer interface. This thesis describes the design and validation of this new water vapor DIAL detection system which was integrated onto a small Printed Circuit Board (PCB) with minimal weight and power consumption. Comparing its measurements to an existing DIAL system for aerosol and water vapor profiling validated the detection system.

  17. Multisignal detecting system of pile integrity testing

    NASA Astrophysics Data System (ADS)

    Liu, Zuting; Luo, Ying; Yu, Shihai

    2002-05-01

    The low strain reflection wave method plays a principal rule in the integrating detection of base piles. However, there are some deficiencies with this method. For example, there is a blind area of detection on top of the tested pile; it is difficult to recognize the defects at deep-seated parts of the pile; there is still the planar of 3D domino effect, etc. It is very difficult to solve these problems only with the single-transducer pile integrity testing system. A new multi-signal piles integrity testing system is proposed in this paper, which is able to impulse and collect signals on multiple points on top of the pile. By using the multiple superposition data processing method, the detecting system can effectively restrain the interference and elevate the precision and SNR of pile integrity testing. The system can also be applied to the evaluation of engineering structure health.

  18. Early screening of an infant's visual system

    NASA Astrophysics Data System (ADS)

    Costa, Manuel F. M.; Jorge, Jorge M.

    1999-06-01

    It is of utmost importance to the development of the child's visual system that she perceives clear focused retinal images. Furthermore if the refractive problems are not corrected in due time amblyopia may occur--myopia and hyperopia can only cause important problems in the future when they are significantly large, however for the astigmatism (rather frequent in infants) and anisometropia the problems tend to be more stringent. The early evaluation of the visual status of human infants is thus of critical importance. Photorefraction is a convenient technique for this kind of subjects. Essentially a light beam is delivered into the eyes. It is refracted by the ocular media, strikes the retina, focusing or not, reflects off and is collected by a camera. The photorefraction setup we established using new technological breakthroughs on the fields of imaging devices, digital image processing and fiber optics, allows a fast noninvasive evaluation of children visual status (refractive errors, accommodation, strabismus, ...). Results of the visual screening of a group of risk' child descents of blinds or amblyopes will be presented.

  19. Early detection network design and search strategy issues

    EPA Science Inventory

    We conducted a series of field and related modeling studies (2005-2012) to evaluate search strategies for Great Lakes coastal ecosystems that are at risk of invasion by non-native aquatic species. In developing a network, we should design to achieve an acceptable limit of detect...

  20. Distributed optical fibre sensing for early detection of shallow landslides triggering.

    PubMed

    Schenato, Luca; Palmieri, Luca; Camporese, Matteo; Bersan, Silvia; Cola, Simonetta; Pasuto, Alessandro; Galtarossa, Andrea; Salandin, Paolo; Simonini, Paolo

    2017-10-31

    A distributed optical fibre sensing system is used to measure landslide-induced strains on an optical fibre buried in a large scale physical model of a slope. The fibre sensing cable is deployed at the predefined failure surface and interrogated by means of optical frequency domain reflectometry. The strain evolution is measured with centimetre spatial resolution until the occurrence of the slope failure. Standard legacy sensors measuring soil moisture and pore water pressure are installed at different depths and positions along the slope for comparison and validation. The evolution of the strain field is related to landslide dynamics with unprecedented resolution and insight. In fact, the results of the experiment clearly identify several phases within the evolution of the landslide and show that optical fibres can detect precursory signs of failure well before the collapse, paving the way for the development of more effective early warning systems.

  1. Prevention and Early Detection of Occupational Cancers - a View of Information Technology Solutions.

    PubMed

    Davoodi, Somayeh; Safdari, Reza; Ghazisaeidi, Marjan; Mohammadzadeh, Zeinab; Azadmanjir, Zahra

    2015-01-01

    Thousands of people die each year from cancer due to occupational causes. To reduce cancer in workers, preventive strategies should be used in the high-risk workplace. The effective prevention of occupational cancer requires knowledge of carcinogen agents. Like other areas of healthcare industry, occupational health has been affected by information technology solutions to improve prevention, early detection, treatment and finally the efficiency and cost effectiveness of the healthcare system. Information technology solutions are thus an important issue in the healthcare field. Information about occupational cancer in information systems is important for policy makers, managers, physicians, patients and researchers; because examples that include high quality data about occupational cancer patients and occupational cancer causes are able to determine the worker groups which require special attention. As a result exposed workers who are vulnerable can undergo screening and be considered for preventive interventions.

  2. Automatic Road Gap Detection Using Fuzzy Inference System

    NASA Astrophysics Data System (ADS)

    Hashemi, S.; Valadan Zoej, M. J.; Mokhtarzadeh, M.

    2011-09-01

    Automatic feature extraction from aerial and satellite images is a high-level data processing which is still one of the most important research topics of the field. In this area, most of the researches are focused on the early step of road detection, where road tracking methods, morphological analysis, dynamic programming and snakes, multi-scale and multi-resolution methods, stereoscopic and multi-temporal analysis, hyper spectral experiments, are some of the mature methods in this field. Although most researches are focused on detection algorithms, none of them can extract road network perfectly. On the other hand, post processing algorithms accentuated on the refining of road detection results, are not developed as well. In this article, the main is to design an intelligent method to detect and compensate road gaps remained on the early result of road detection algorithms. The proposed algorithm consists of five main steps as follow: 1) Short gap coverage: In this step, a multi-scale morphological is designed that covers short gaps in a hierarchical scheme. 2) Long gap detection: In this step, the long gaps, could not be covered in the previous stage, are detected using a fuzzy inference system. for this reason, a knowledge base consisting of some expert rules are designed which are fired on some gap candidates of the road detection results. 3) Long gap coverage: In this stage, detected long gaps are compensated by two strategies of linear and polynomials for this reason, shorter gaps are filled by line fitting while longer ones are compensated by polynomials.4) Accuracy assessment: In order to evaluate the obtained results, some accuracy assessment criteria are proposed. These criteria are obtained by comparing the obtained results with truly compensated ones produced by a human expert. The complete evaluation of the obtained results whit their technical discussions are the materials of the full paper.

  3. Sophisticated digestive systems in early arthropods.

    PubMed

    Vannier, Jean; Liu, Jianni; Lerosey-Aubril, Rudy; Vinther, Jakob; Daley, Allison C

    2014-05-02

    Understanding the way in which animals diversified and radiated during their early evolutionary history remains one of the most captivating of scientific challenges. Integral to this is the 'Cambrian explosion', which records the rapid emergence of most animal phyla, and for which the triggering and accelerating factors, whether environmental or biological, are still unclear. Here we describe exceptionally well-preserved complex digestive organs in early arthropods from the early Cambrian of China and Greenland with functional similarities to certain modern crustaceans and trace these structures through the early evolutionary lineage of fossil arthropods. These digestive structures are assumed to have allowed for more efficient digestion and metabolism, promoting carnivory and macrophagy in early arthropods via predation or scavenging. This key innovation may have been of critical importance in the radiation and ecological success of Arthropoda, which has been the most diverse and abundant invertebrate phylum since the Cambrian.

  4. Early Detection Monitoring for Invasive Fish: St. Louis River (SLR) Pilot Study

    EPA Science Inventory

    Early detection of aquatic invasive species is necessary to develop and implement timely management responses. Predicting species introductions, however, is difficult and resources are typically limited. Therefore, monitoring strategies should be designed to effectively and eff...

  5. Potential Landslide Early Detection Near Wenchuan by a Qualitatively Multi-Baseline Dinsar Method

    NASA Astrophysics Data System (ADS)

    Dai, K.; Chen, G.; Xu, Q.; Li, Z.; Qu, T.; Hu, L.; Lu, H.

    2018-04-01

    Early detection of landslides is important for disaster prevention, which was still very hard work with traditional surveying methods. Interferometric Synthetic Aperture Radar (InSAR) technology provided us the ability to monitor displacements along the slope with wide coverage and high accuracy. In this paper, we proposed a qualitatively multi-baseline DInSAR method to early detect and map the potential landslides. Two sections of China National Highway 317 and 213 were selected as study area. With this method 10 potential landslide areas were early detected and mapped in a quick and effective way. One of them (i.e. Shidaguan landslide) collapsed on August 2017, which was coincident with our results, suggesting that this method could become an effective way to acquire the landslide early detection map to assist the future disaster prevention work.

  6. DCP's Early Detection Research Guides Future Science | Division of Cancer Prevention

    Cancer.gov

    Early detection research funded by the NCI's Division of Cancer Prevention has positively steered both public health and clinical outcomes, and set the stage for findings in the next generation of research. |

  7. Use of digital PCR to improve early detection of CLas infection

    Huanglongbing is a devastating disease of citrus caused by the bacterium Candidatus Liberibacter asiaticus. Huanglongbing has devastated the Florida citrus industry and is threatening citrus in Texas and California. Detection of Candidatus Liberibacter asiaticus infections as early as possible is ...

  8. Early Alzheimer's Disease Neuropathology Detected by Proton MR Spectroscopy

    PubMed Central

    Murray, Melissa E.; Przybelski, Scott A.; Lesnick, Timothy G.; Liesinger, Amanda M.; Spychalla, Anthony; Zhang, Bing; Gunter, Jeffrey L.; Parisi, Joseph E.; Boeve, Bradley F.; Knopman, David S.; Petersen, Ronald C.; Jack, Clifford R.; Dickson, Dennis W.

    2014-01-01

    Proton magnetic resonance spectroscopy (1H-MRS) is sensitive to early neurodegenerative processes associated with Alzheimer's disease (AD). Although 1H-MRS metabolite ratios of N-acetyl aspartate (NAA)/creatine (Cr), NAA/myoinositol (mI), and mI/Cr measured in the posterior cingulate gyrus reveal evidence of disease progression in AD, pathologic underpinnings of the 1H-MRS metabolite changes in AD are unknown. Pathologically diagnosed human cases ranging from no likelihood to high likelihood AD (n = 41, 16 females and 25 males) who underwent antemortem 1H-MRS of the posterior cingulate gyrus at 3 tesla were included in this study. Immunohistochemical evaluation was performed on the posterior cingulate gyrus using antibodies to synaptic vesicles, hyperphosphorylated tau (pTau), neurofibrillary tangle conformational-epitope (cNFT), amyloid-β, astrocytes, and microglia. The slides were digitally analyzed using Aperio software, which allows neuropathologic quantification in the posterior cingulate gray matter. MRS and pathology associations were adjusted for time from scan to death. Significant associations across AD and control subjects were found between reduced synaptic immunoreactivity and both NAA/Cr and NAA/mI in the posterior cingulate gyrus. Higher pTau burden was associated with lower NAA/Cr and NAA/mI. Higher amyloid-β burden was associated with elevated mI/Cr and lower NAA/mI ratios, but not with NAA/Cr. 1H-MRS metabolite levels reveal early neurodegenerative changes associated with AD pathology. Our findings support the hypothesis that a decrease in NAA/Cr is associated with loss of synapses and early pTau pathology, but not with amyloid-β or later accumulation of cNFT pathology in the posterior cingulate gyrus. In addition, elevation of mI/Cr is associated with the occurrence of amyloid-β plaques in AD. PMID:25471565

  9. Early pest detection in soy plantations from hyperspectral measurements: a case study for caterpillar detection

    NASA Astrophysics Data System (ADS)

    Tailanián, Matías; Castiglioni, Enrique; Musé, Pablo; Fernández Flores, Germán.; Lema, Gabriel; Mastrángelo, Pedro; Almansa, Mónica; Fernández Liñares, Ignacio; Fernández Liñares, Germán.

    2015-10-01

    Soybean producers suffer from caterpillar damage in many areas of the world. Estimated average economic losses are annually 500 million USD in Brazil, Argentina, Paraguay and Uruguay. Designing efficient pest control management using selective and targeted pesticide applications is extremely important both from economic and environmental perspectives. With that in mind, we conducted a research program during the 2013-2014 and 2014-2015 planting seasons in a 4,000 ha soybean farm, seeking to achieve early pest detection. Nowadays pest presence is evaluated using manual, labor-intensive counting methods based on sampling strategies which are time consuming and imprecise. The experiment was conducted as follows. Using manual counting methods as ground-truth, a spectrometer capturing reflectance from 400 to 1100 nm was used to measure the reflectance of soy plants. A first conclusion, resulting from measuring the spectral response at leaves level, showed that stress was a property of plants since different leaves with different levels of damage yielded the same spectral response. Then, to assess the applicability of unsupervised classification of plants as healthy, biotic-stressed or abiotic-stressed, feature extraction and selection from leaves spectral signatures, combined with a Supported Vector Machine classifier was designed. Optimization of SVM parameters using grid search with cross-validation, along with classification evaluation by ten-folds cross-validation showed a correct classification rate of 95%, consistently on both seasons. Controlled experiments using cages with different numbers of caterpillars--including caterpillar-free plants--were also conducted to evaluate consistency in trends of the spectral response as well as the extracted features.

  10. Early detection of psychosis - establishing a service for persons at risk.

    PubMed

    Schultze-Lutter, Frauke; Ruhrmann, Stephan; Klosterkötter, Joachim

    2009-01-01

    The establishment phase of an early detection centre for prodromal psychosis is introduced and characterised, along with its detaining and promoting factors within a universal multi-payer health care system. Across the first six years (1998-2003), users' characteristics are compared between different diagnostic groups and to the local population statistics; and, for an exemplary 12-months period (3-1-2002 to 2-28-2003), the characteristics of telephone contacts with the service are studied. Rising steadily in number across the first three years, 872 persons, predominantly of German citizenship and higher education, consulted the service until 2003, 326 with first-episode psychosis and 144 not fulfilling criteria for a current or beginning psychosis. Of the 402 putatively prodromal patients, 94% reported predictive basic symptoms, 68.9% attenuated and 20.6% transient psychotic symptoms. Most contacts by persons meeting any prodromal criterion were initiated by mental health professionals (psychiatrists or psychologists) and counselling services. Supported by public awareness campaigns, an early detection service is well received by its users and private practitioners as reflected by the large proportion of referrals from the latter. However, persons of non-German background as well as of lower education were underrepresented indicating that these sub-groups should be approached by tailored programmes.

  11. Automated classification of mandibular cortical bone on dental panoramic radiographs for early detection of osteoporosis

    NASA Astrophysics Data System (ADS)

    Horiba, Kazuki; Muramatsu, Chisako; Hayashi, Tatsuro; Fukui, Tatsumasa; Hara, Takeshi; Katsumata, Akitoshi; Fujita, Hiroshi

    2015-03-01

    Findings on dental panoramic radiographs (DPRs) have shown that mandibular cortical index (MCI) based on the morphology of mandibular inferior cortex was significantly correlated with osteoporosis. MCI on DPRs can be categorized into one of three groups and has the high potential for identifying patients with osteoporosis. However, most DPRs are used only for diagnosing dental conditions by dentists in their routine clinical work. Moreover, MCI is not generally quantified but assessed subjectively. In this study, we investigated a computer-aided diagnosis (CAD) system that automatically classifies mandibular cortical bone for detection of osteoporotic patients at early stage. First, an inferior border of mandibular bone was detected by use of an active contour method. Second, regions of interest including the cortical bone are extracted and analyzed for its thickness and roughness. Finally, support vector machine (SVM) differentiate cases into three MCI categories by features including the thickness and roughness. Ninety eight DPRs were used to evaluate our proposed scheme. The number of cases classified to Class I, II, and III by a dental radiologist are 56, 25 and 17 cases, respectively. Experimental result based on the leave-one-out cross-validation evaluation showed that the sensitivities for the classes I, II, and III were 94.6%, 57.7% and 94.1%, respectively. Distribution of the groups in the feature space indicates a possibility of MCI quantification by the proposed method. Therefore, our scheme has a potential in identifying osteoporotic patients at an early stage.

  12. Fault detection and isolation for complex system

    NASA Astrophysics Data System (ADS)

    Jing, Chan Shi; Bayuaji, Luhur; Samad, R.; Mustafa, M.; Abdullah, N. R. H.; Zain, Z. M.; Pebrianti, Dwi

    2017-07-01

    Fault Detection and Isolation (FDI) is a method to monitor, identify, and pinpoint the type and location of system fault in a complex multiple input multiple output (MIMO) non-linear system. A two wheel robot is used as a complex system in this study. The aim of the research is to construct and design a Fault Detection and Isolation algorithm. The proposed method for the fault identification is using hybrid technique that combines Kalman filter and Artificial Neural Network (ANN). The Kalman filter is able to recognize the data from the sensors of the system and indicate the fault of the system in the sensor reading. Error prediction is based on the fault magnitude and the time occurrence of fault. Additionally, Artificial Neural Network (ANN) is another algorithm used to determine the type of fault and isolate the fault in the system.

  13. Coal-shale interface detection system

    NASA Technical Reports Server (NTRS)

    Campbell, R. A.; Hudgins, J. L.; Morris, P. W.; Reid, H., Jr.; Zimmerman, J. E. (Inventor)

    1979-01-01

    A coal-shale interface detection system for use with coal cutting equipment consists of a reciprocating hammer on which an accelerometer is mounted to measure the impact of the hammer as it penetrates the ceiling or floor surface of a mine. A pair of reflectometers simultaneously view the same surface. The outputs of the accelerometer and reflectometers are detected and jointly registered to determine when an interface between coal and shale is being cut through.

  14. Nanotechnology-Based Detection of Novel microRNAs for Early Diagnosis of Prostate Cancer

    DTIC Science & Technology

    2016-08-01

    1 AD _________________ AWARD NUMBER: W81XWH-15-1-0157 TITLE: Nanotechnology -Based Detection of Novel microRNAs for Early Diagnosis of Prostate...DATES COVERED 15 Jul 2015 - 14 Jul 2016 4. TITLE AND SUBTITLE Nanotechnology -Based Detection of Novel microRNAs for Early Diagnosis of Prostate Cancer...the expression level of deregulated miRNAs in mouse and human PCa tissues as well as serum samples using an advanced nanotechnology -based sensing

  15. Edge detection techniques for iris recognition system

    NASA Astrophysics Data System (ADS)

    Tania, U. T.; Motakabber, S. M. A.; Ibrahimy, M. I.

    2013-12-01

    Nowadays security and authentication are the major parts of our daily life. Iris is one of the most reliable organ or part of human body which can be used for identification and authentication purpose. To develop an iris authentication algorithm for personal identification, this paper examines two edge detection techniques for iris recognition system. Between the Sobel and the Canny edge detection techniques, the experimental result shows that the Canny's technique has better ability to detect points in a digital image where image gray level changes even at slow rate.

  16. Automated macromolecular crystal detection system and method

    DOEpatents

    Christian, Allen T [Tracy, CA; Segelke, Brent [San Ramon, CA; Rupp, Bernard [Livermore, CA; Toppani, Dominique [Fontainebleau, FR

    2007-06-05

    An automated macromolecular method and system for detecting crystals in two-dimensional images, such as light microscopy images obtained from an array of crystallization screens. Edges are detected from the images by identifying local maxima of a phase congruency-based function associated with each image. The detected edges are segmented into discrete line segments, which are subsequently geometrically evaluated with respect to each other to identify any crystal-like qualities such as, for example, parallel lines, facing each other, similarity in length, and relative proximity. And from the evaluation a determination is made as to whether crystals are present in each image.

  17. Towards an Automated Acoustic Detection System for Free Ranging Elephants.

    PubMed

    Zeppelzauer, Matthias; Hensman, Sean; Stoeger, Angela S

    The human-elephant conflict is one of the most serious conservation problems in Asia and Africa today. The involuntary confrontation of humans and elephants claims the lives of many animals and humans every year. A promising approach to alleviate this conflict is the development of an acoustic early warning system. Such a system requires the robust automated detection of elephant vocalizations under unconstrained field conditions. Today, no system exists that fulfills these requirements. In this paper, we present a method for the automated detection of elephant vocalizations that is robust to the diverse noise sources present in the field. We evaluate the method on a dataset recorded under natural field conditions to simulate a real-world scenario. The proposed method outperformed existing approaches and robustly and accurately detected elephants. It thus can form the basis for a future automated early warning system for elephants. Furthermore, the method may be a useful tool for scientists in bioacoustics for the study of wildlife recordings.

  18. Neuromotor outcomes at school age after extremely low birth weight: early detection of subtle signs.

    PubMed

    Gidley Larson, Jennifer C; Baron, Ida Sue; Erickson, Kristine; Ahronovich, Margot D; Baker, Robin; Litman, Fern R

    2011-01-01

    Motor impairments are prevalent in children born at extremely low birth weight (ELBW; <1,000 g). Rarely studied are subtle motor deficits that indicate dysfunction or delay in neural systems critical for optimal cognitive, academic, and behavioral function. We aimed to examine quantifiable signs of subtle neuromotor dysfunction in an early school-aged ELBW cohort that coincidentally had age-appropriate cognition and design copying. We studied 97 participants born between 1998 and 2001; 74 ELBW (6.7 years ± 0.75) compared with 23 term-born (6.6 years ± 0.29). Neuromotor outcomes were assessed using the Physical and Neurological Examination of Subtle Signs-Revised, and measures of dexterity/coordination and visual-motor integration. ELBW participants performed worse than term-born on design-copying and dexterity, were age-appropriate compared to normative data, and had slower timed movements and more subtle overflow movements. Those ELBW born <26 weeks performed most poorly compared with those born 26-34 weeks and term-born. Subtle motor dysfunctions are detectable and quantifiable in ELBW children by school age, even in the presence of average cognition. Early age assessment of incoordination, motor speed, and overflow movements should aid initiation of timely therapies to prepare at-risk ELBW children for subsequent school entry and facilitate design of optimal early treatment strategies. (c) 2010 APA, all rights reserved.

  19. Implementing drought early warning systems: policy lessons and future needs

    NASA Astrophysics Data System (ADS)

    Iglesias, Ana; Werner, Micha; Maia, Rodrigo; Garrote, Luis; Nyabeze, Washington

    2014-05-01

    Drought forecasting and Warning provides the potential of reducing impacts to society due to drought events. The implementation of effective drought forecasting and warning, however, requires not only science to support reliable forecasting, but also adequate policy and societal response. Here we propose a protocol to develop drought forecasting and early warning based in the international cooperation of African and European institutions in the DEWFORA project (EC, 7th Framework Programme). The protocol includes four major phases that address the scientific knowledge and the social capacity to use the knowledge: (a) What is the science available? Evaluating how signs of impending drought can be detected and predicted, defining risk levels, and analysing of the signs of drought in an integrated vulnerability approach. (b) What are the societal capacities? In this the institutional framework that enables policy development is evaluated. The protocol gathers information on vulnerability and pending hazard in advance so that early warnings can be declared at sufficient lead time and drought mitigation planning can be implemented at an early stage. (c) How can science be translated into policy? Linking science indicators into the actions/interventions that society needs to implement, and evaluating how policy is implemented. Key limitations to planning for drought are the social capacities to implement early warning systems. Vulnerability assessment contributes to identify these limitations and therefore provides crucial information to policy development. Based on the assessment of vulnerability we suggest thresholds for management actions to respond to drought forecasts and link predictive indicators to relevant potential mitigation strategies. Vulnerability assessment is crucial to identify relief, coping and management responses that contribute to a more resilient society. (d) How can society benefit from the forecast? Evaluating how information is provided to

  20. Early Detection of Pandemic (H1N1) 2009, Bangladesh

    PubMed Central

    Rahman, Mustafizur; Al Mamun, Abdullah; Haider, Mohammad Sabbir; Zaman, Rashid Uz; Karmakar, Polash Chandra; Nasreen, Sharifa; Muneer, Syeda Mah-E; Homaira, Nusrat; Goswami, Doli Rani; Ahmed, Be-Nazir; Husain, Mohammad Mushtuq; Jamil, Khondokar Mahbuba; Khatun, Selina; Ahmed, Mujaddeed; Chakraborty, Apurba; Fry, Alicia; Widdowson, Marc-Alain; Bresee, Joseph; Azim, Tasnim; Alamgir, A.S.M.; Brooks, Abdullah; Hossain, Mohamed Jahangir; Klimov, Alexander; Rahman, Mahmudur; Luby, Stephen P.

    2012-01-01

    To explore Bangladesh’s ability to detect novel influenza, we examined a series of laboratory-confirmed pandemic (H1N1) 2009 cases. During June–July 2009, event-based surveillance identified 30 case-patients (57% travelers); starting July 29, sentinel sites identified 252 case-patients (1% travelers). Surveillance facilitated response weeks before the spread of pandemic (H1N1) 2009 infection to the general population. PMID:22257637

  1. Gram-positive Rod Surveillance for Early Anthrax Detection

    PubMed Central

    Begier, Elizabeth M.; Barrett, Nancy L.; Mshar, Patricia A.; Johnson, David G.

    2005-01-01

    Connecticut established telephone-based gram-positive rod (GPR) reporting primarily to detect inhalational anthrax cases more quickly. From March to December 2003, annualized incidence of blood isolates was 21.3/100,000 persons; reports included 293 Corynebacterium spp., 193 Bacillus spp., 73 Clostridium spp., 26 Lactobacillus spp., and 49 other genera. Around-the-clock GPR reporting has described GPR epidemiology and enhanced rapid communication with clinical laboratories. PMID:16229790

  2. Early Detection of Breast Cancer Using Molecular Beacons

    DTIC Science & Technology

    2008-01-01

    a molecular beacon (MB)-based approach for direct examination of gene expression in viable and fixed cells (2, 3). This objective of proposed study ...can be distinguished from normal cells (dark) (Figure 1) (2, 3, 8). Recently, a class of new fluorescent emitting nanoparticles, semiconductor ...morphological classification. This method may offer a simple and fast procedure to detect biomarker gene expression in clinical samples. Our study results

  3. [Colonoscopy for early detection and prevention of colorectal cancer].

    PubMed

    Niv, Yaron

    2010-08-01

    Colonoscopy has a limited success in the prevention of colorectal cancer of the right colon. Thus, there is place for improvement. The potential reasons for colonoscopy failure are the different biology of polyps on the right side of the colon or procedure quality. Preparation, withdrawal time, detection of all polyps and their removal using the best technique will overcome this problem. Furthermore, the implementation of a computerized database and report that includes quality assurance fields, will improve colonoscopy success rates.

  4. Transitions for Young Children: Creating Connections across Early Childhood Systems

    ERIC Educational Resources Information Center

    Kagan, Sharon Lynn, Ed.; Tarrant, Kate, Ed.

    2010-01-01

    Smooth early childhood transitions are key to ensuring positive outcomes for young children the world over--but in today's fragmented early education systems, it's difficult to ensure continuity among programs and services. Early childhood professionals will help change that with this book, the first to propose a comprehensive, practical framework…

  5. Effective Partnering of State Agencies to Achieve Early Hearing Detection and Intervention Benchmarks

    ERIC Educational Resources Information Center

    Corwin, Joanne

    2011-01-01

    Relative to Early Hearing Detection and Intervention (EHDI), New Mexico struggles with multiple points of referral into early intervention in the same way most states do. Referrals are not systematized through a single point of entry. The Step*Hi (statewide Parent-Infant) Program of the New Mexico School for the Deaf (NMSD) receives referrals from…

  6. The Importance of Distinguishing "Propensity" versus "Ability" to Imitate in ASD Research and Early Detection

    ERIC Educational Resources Information Center

    Vivanti, Giacomo

    2015-01-01

    Imitation abnormalities are often documented in young children with Autism Spectrum Disorder (ASD), however the relevance of imitation to early development and early detection of ASD remains unclear. Recent studies that investigated whether imitation at 12 months distinguishes children who will subsequently receive an ASD diagnosis from other…

  7. Early Hearing Detection and Intervention in Developing Countries: Current Status and Prospects

    ERIC Educational Resources Information Center

    Olusanya, Bolajoko O.

    2006-01-01

    Infant hearing screening is emerging rapidly as a silent global revolution for the early detection of children with congenital or early onset hearing loss to ensure timely enrollment in family-oriented intervention programs for the development of spoken language. This article examines the overriding and interrelated scientific, ethical and…

  8. The Earthquake Early Warning System in Japan (Invited)

    NASA Astrophysics Data System (ADS)

    Mori, J. J.; Yamada, M.

    2010-12-01

    In Japan, the earthquake early warning system (Kinkyu Jishin Sokuhou in Japanese) maintained by the Japan Meterological Agency (JMA) has been in operation and sending pubic information since October 1, 2007. Messages have been broadcast on television and radio to warn of strong shaking to the public. The threshold for broadcasting a message is an estimated intensity of JMA 5 lower, which is approximately equivalent to MM VII to VIII. During the period from October 2007 through August 2010, messages have been sent 9 times for earthquakes of magnitude 5.2 to 7.0. There have been a few instances of significantly over-estimating or under-estimating the predicted shaking, but in general the performance of the system has been quite good. The quality of the detection system depends on the dense network of high-quality seismometers that cover the Japanese Islands. Consequently, the system works very well for events on or close to the 4 main islands, but there is more uncertainty for events near the smaller and more distant islands where the density of instrumentation is much less The Early Warning System is also tied to an extensive education program so that the public can react appropriately in the short amount of time given by the warning. There appears to be good public support in Japan, where people have become accustomed to a high level of fast information on a daily basis. There has also been development of a number of specific safety applications in schools and industry that work off the backbone information provided in the national system.

  9. An Attempt of Early Detection of Poor Outcome after Whiplash

    PubMed Central

    Laporte, Sebastien; Wang, Danping; Lecompte, Jennyfer; Blancho, Sophie; Sandoz, Baptiste; Feydy, Antoine; Lindberg, Pavel; Adrian, Julien; Chiarovano, Elodie; de Waele, Catherine; Vidal, Pierre-Paul

    2016-01-01

    The main concern with whiplash is that a large proportion of whiplash patients experience disabling symptoms or whiplash-associated disorders (WAD) for months if not years following the accident. Therefore, identifying early prognostic factors of WAD development is important as WAD have widespread clinical and economic consequences. In order to tackle that question, our study was specifically aimed at combining several methods of investigation in the same WAD patients at the acute stage and 6 months later. Our longitudinal, open, prospective, multi-center study included 38 whiplash patients, and 13 healthy volunteers matched for age, gender, and socio-economic status with the whiplash group. Whiplash patients were evaluated 15–21 days after road accident, and 6 months later. At each appointment, patients underwent a neuropsychological evaluation, a full clinical neurological examination, neurophysiological and postural tests, oto-neurological tests, cervical spine cord magnetic resonance imaging (MRI) with tractography (DTI). At 6 months, whiplash patients were categorized into two subgroups based on the results of the Diagnostic and Statistical Manual of Mental Disorders as having either favorable or unfavorable progression [an unfavorable classification corresponding to the presence of post-concussion symptom (PCS)] and we searched retrospectively for early prognostic factors of WAD predicting the passage to chronicity. We found that patients displaying high level of catastrophizing at the acute stage and/or post-traumatic stress disorder associated with either abnormalities in head or trunk kinematics, abnormal test of the otolithic function and at the Equitest or a combination of these syndromes, turned to chronicity. This study suggests that low-grade whiplash patients should be submitted as early as possible after the trauma to neuropsychological and motor control tests in a specialized consultation. In addition, they should be evaluated by a neuro

  10. Maximum Temperature Detection System for Integrated Circuits

    NASA Astrophysics Data System (ADS)

    Frankiewicz, Maciej; Kos, Andrzej

    2015-03-01

    The paper describes structure and measurement results of the system detecting present maximum temperature on the surface of an integrated circuit. The system consists of the set of proportional to absolute temperature sensors, temperature processing path and a digital part designed in VHDL. Analogue parts of the circuit where designed with full-custom technique. The system is a part of temperature-controlled oscillator circuit - a power management system based on dynamic frequency scaling method. The oscillator cooperates with microprocessor dedicated for thermal experiments. The whole system is implemented in UMC CMOS 0.18 μm (1.8 V) technology.

  11. Application of multispectral reflectance for early detection of tomato disease

    NASA Astrophysics Data System (ADS)

    Xu, Huirong; Zhu, Shengpan; Ying, Yibin; Jiang, Huanyu

    2006-10-01

    Automatic diagnosis of plant disease is important for plant management and environmental preservation in the future. The objective of this study is to use multispectral reflectance measurements to make an early discrimination between the healthy and infected plants by the strain of tobacco mosaic virus (TMV-U1) infection. There were reflectance changes in the visible (VIS) and near infrared spectroscopy (NIR) between the healthy and infected plants. Discriminant models were developed using discriminant partial least squares (DPLS) and Mahalanobis distance (MD). The DPLS models had a root mean square error of calibration (RMSEC) of 0.397 and correlation coefficient (r) of 0.59 and the MD model correctly classified 86.7% healthy plants and up to 91.7% infected plants.

  12. Neonatal and early infancy management of prenatally detected hydronephrosis.

    PubMed

    Swords, Kelly A; Peters, Craig A

    2015-09-01

    Hydronephrosis discovered during prenatal ultrasound will often resolve spontaneously; however, it should be evaluated in the postnatal period in a manner commensurate with its risk of renal injury. Early intervention is appropriate in cases of bladder outlet obstruction or the severely obstructed solitary kidney. In most other cases, it is both safe and reasonable to allow the possibility of spontaneous improvement with the intensity of follow-up based on the severity of the hydronephrosis. Clinical decision making should be a shared process between families and caregivers. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. Detection of occupational lead nephropathy using early renal markers.

    PubMed

    Kumar, B D; Krishnaswamy, K

    1995-01-01

    Automotive use of leaded gasoline continues to be an important source of occupational exposure to lead in India and other countries. The present study assessed the renal function and markers of early renal damage of 22 mechanics at three automobile garages. Urinary N-acetyl-3-D-glucosaminidase activity and beta-2-microglobulin levels were significantly increased in auto garage mechanics with blood leads of 30-69 micrograms/dL. A significant correlation was observed between blood lead levels and urinary N-acetyl-3-D-glucosaminidase activity but not with urine beta-2-microglobulin levels. A marginal impairment in creatinine clearance was not statistically significant. Urinary N-acetyl-3-D-glucosaminidase activity offers a sensitive monitor of blood lead and renal tubular injury.

  14. Supporting State Systems of Early Learning Act

    THOMAS, 112th Congress

    Rep. Himes, James A. [D-CT-4

    2011-11-02

    House - 11/18/2011 Referred to the Subcommittee on Early Childhood, Elementary, and Secondary Education. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  15. System for particle concentration and detection

    DOEpatents

    Morales, Alfredo M.; Whaley, Josh A.; Zimmerman, Mark D.; Renzi, Ronald F.; Tran, Huu M.; Maurer, Scott M.; Munslow, William D.

    2013-03-19

    A new microfluidic system comprising an automated prototype insulator-based dielectrophoresis (iDEP) triggering microfluidic device for pathogen monitoring that can eventually be run outside the laboratory in a real world environment has been used to demonstrate the feasibility of automated trapping and detection of particles. The system broadly comprised an aerosol collector for collecting air-borne particles, an iDEP chip within which to temporarily trap the collected particles and a laser and fluorescence detector with which to induce a fluorescence signal and detect a change in that signal as particles are trapped within the iDEP chip.

  16. PROPOSED WATER QUALITY SURVEILLANCE NETWORK USING PHYSICAL, CHEMICAL AND BIOLOGICAL EARLY WARNING SYSTEMS (CBEWS)

    EPA Science Inventory

    The Homeland Protection Act of 2002 specifically calls for the investigation and use of Early Warning Systems (EWS) for water security reasons. The EWS is a screening tool for detecting changes in source water and distribution system water quality. A suite of time-relevant biol...

  17. PROPOSED WATER QUALITY SURVEILLANCE NETWORK USING PHYSICAL, CHEMICAL AND BIOLOGICAL EARLY WARNING SYSTEMS (BEWS)

    EPA Science Inventory

    The Homeland Protection Act of 2002 specifically calls for the investigation and use of Early Warning Systems (EWS) for water security reasons. The EWS is a screening tool for detecting changes in source water and distribution system water quality. A suite of time-relevant biol...

  18. [Usefullness of transesophageal echocardiography in early detection of coronary spasm].

    PubMed

    Sagara, M; Haraguchi, M; Hamu, Y; Isowaki, S; Yoshimura, N

    1996-04-01

    Intraoperative transesophageal echocardiography (TEE) was performed on a 62-year-old man who underwent abdominal aortic replacement for abdominal aortic aneurysm under general anesthesia combined with epidural anesthesia. Coronary artery spasm occurred after unexpected massive hemorrhage, and TEE showed hypokinesis in the posterior-inferior left ventricular wall. The changes in TEE preceded the ST elevation in the ECG. Bolus infusion of isosorbide dinitrate and continuous infusion of nitroglycerin alleviated these changes. TEE enabled us to detect and evaluate coronary spasm before the appearance of ST changes in ECG.

  19. Application of nanotechnology in cancers prevention, early detection and treatment.

    PubMed

    Patel, Shraddha P; Patel, Parshottambhai B; Parekh, Bhavesh B

    2014-01-01

    Use of nanotechnology in medical science is a rapidly developing area. New opportunities of diagnosis, imaging and therapy have developed due to recent rapid advancement by nanotechnology. The most common areas to be affected are diagnostic, imaging and targeted drug delivery in gastroenterology, oncology, cardiovascular medicine, obstetrics and gynecology. Mass screening with inexpensive imaging might be possible in the near future with the help of nanotechnology. This review paper provides an overview of causes of cancer and the application of nanotechnology in cancer prevention, detection and treatment.

  20. Devising a method towards development of early warning tool for detection of malaria outbreak.

    PubMed

    Verma, Preeti; Sarkar, Soma; Singh, Poonam; Dhiman, Ramesh C

    2017-11-01

    Uncertainty often arises in differentiating seasonal variation from outbreaks of malaria. The present study was aimed to generalize the theoretical structure of sine curve for detecting an outbreak so that a tool for early warning of malaria may be developed. A 'case/mean-ratio scale' system was devised for labelling the outbreak in respect of two diverse districts of Assam and Rajasthan. A curve-based method of analysis was developed for determining outbreak and using the properties of sine curve. It could be used as an early warning tool for Plasmodium falciparum malaria outbreaks. In the present method of analysis, the critical C max (peak value of sine curve) value of seasonally adjusted curve for P. falciparum malaria outbreak was 2.3 for Karbi Anglong and 2.2 for Jaisalmer districts. On case/mean-ratio scale, the C max value of malaria curve between C max and 3.5, the outbreak could be labelled as minor while >3.5 may be labelled as major. In epidemic years, with mean of case/mean ratio of ≥1.00 and root mean square (RMS) ≥1.504 of case/mean ratio, outbreaks can be predicted 1-2 months in advance. The present study showed that in P. falciparum cases in Karbi Anglong (Assam) and Jaisalmer (Rajasthan) districts, the rise in C max value of curve was always followed by rise in average/RMS or both and hence could be used as an early warning tool. The present method provides better detection of outbreaks than the conventional method of mean plus two standard deviation (mean+2 SD). The identified tools are simple and may be adopted for preparedness of malaria outbreaks.

  1. A Walk through TRIDEC's intermediate Tsunami Early Warning System

    NASA Astrophysics Data System (ADS)

    Hammitzsch, M.; Reißland, S.; Lendholt, M.

    2012-04-01

    The management of natural crises is an important application field of the technology developed in the project Collaborative, Complex, and Critical Decision-Support in Evolving Crises (TRIDEC), co-funded by the European Commission in its Seventh Framework Programme. TRIDEC is based on the development of the German Indonesian Tsunami Early Warning System (GITEWS) and the Distant Early Warning System (DEWS) providing a service platform for both sensor integration and warning dissemination. In TRIDEC new developments in Information and Communication Technology (ICT) are used to extend the existing platform realising a component-based technology framework for building distributed tsunami warning systems for deployment, e.g. in the North-eastern Atlantic, the Mediterranean and Connected Seas (NEAM) region. The TRIDEC system will be implemented in three phases, each with a demonstrator. Successively, the demonstrators are addressing challenges, such as the design and implementation of a robust and scalable service infrastructure supporting the integration and utilisation of existing resources with accelerated generation of large volumes of data. These include sensor systems, geo-information repositories, simulation tools and data fusion tools. In addition to conventional sensors also unconventional sensors and sensor networks play an important role in TRIDEC. The system version presented is based on service-oriented architecture (SOA) concepts and on relevant standards of the Open Geospatial Consortium (OGC), the World Wide Web Consortium (W3C) and the Organization for the Advancement of Structured Information Standards (OASIS). In this way the system continuously gathers, processes and displays events and data coming from open sensor platforms to enable operators to quickly decide whether an early warning is necessary and to send personalized warning messages to the authorities and the population at large through a wide range of communication channels. The system

  2. Validation of Biomarkers for the Early Detection of Colorectal Adenocarcinoma (GLNE 010) — EDRN Public Portal

    Cancer.gov

    We propose a Phase 2 (large cross-sectional) PRoBE-compliant validation trial of stool-based and serum-based tests for the detection of colorectal neoplasia (1). The trial is powered to detect early stage colorectal adenocarcinoma or high grade dysplasia. This is the most stringent, conservative approach to the early diagnosis of colonic neoplasia and addresses the most important endpoint of identifying individuals with curable, early stage cancer and those with very high risk non-invasive neoplasia (high grade dysplasia).

  3. Building Community Systems for Young Children: Early Childhood Education. Building State Early Childhood Comprehensive Systems Series, Number 11

    ERIC Educational Resources Information Center

    Bassok, Daphna; Stipek, Deborah; Inkelas, Moira; Kuo, Alice

    2005-01-01

    This report examines the importance and funding sources of early child care and education (ECE), and the ways in which the State Early Childhood Comprehensive Systems (SECCS) Initiative improves early childhood outcomes. Section I presents what is known about the importance of ECE, quality and access. Section II describes the current funding…

  4. Spark discharge trace element detection system

    DOEpatents

    Adler-Golden, Steven; Bernstein, Lawrence S.; Bien, Fritz

    1988-01-01

    A spark discharge trace element detection system is provided which includes a spark chamber including a pair of electrodes for receiving a sample of gas to be analyzed at no greater than atmospheric pressure. A voltage is provided across the electrodes for generating a spark in the sample. The intensity of the emitted radiation in at least one primary selected narrow band of the radiation is detected. Each primary band corresponds to an element to be detected in the gas. The intensity of the emission in each detected primary band is integrated during the afterglow time interval of the spark emission and a signal representative of the integrated intensity of the emission in each selected primary bond is utilized to determine the concentration of the corresponding element in the gas.

  5. Spark discharge trace element detection system

    DOEpatents

    Adler-Golden, S.; Bernstein, L.S.; Bien, F.

    1988-08-23

    A spark discharge trace element detection system is provided which includes a spark chamber including a pair of electrodes for receiving a sample of gas to be analyzed at no greater than atmospheric pressure. A voltage is provided across the electrodes for generating a spark in the sample. The intensity of the emitted radiation in at least one primary selected narrow band of the radiation is detected. Each primary band corresponds to an element to be detected in the gas. The intensity of the emission in each detected primary band is integrated during the afterglow time interval of the spark emission and a signal representative of the integrated intensity of the emission in each selected primary bond is utilized to determine the concentration of the corresponding element in the gas. 12 figs.

  6. Materiel requirements for airborne minefield detection system

    NASA Astrophysics Data System (ADS)

    Bertsche, Karl A.; Huegle, Helmut

    1997-07-01

    Within the concept study, Material Requirements for an airborne minefield detection systems (AMiDS) the following topics were investigated: (i) concept concerning airborne minefield detection technique sand equipment, (ii) verification analysis of the AMiDS requirements using simulation models and (iii) application concept of AMiDS with regard o tactics and military operations. In a first approach the problems concerning unmanned airborne minefield detection techniques within a well-defined area were considered. The complexity of unmanned airborne minefield detection is a result of the following parameters: mine types, mine deployment methods, tactical requirements, topography, weather conditions, and the size of the area to be searched. In order to perform the analysis, a simulation model was developed to analyze the usability of the proposed remote controlled air carriers. The basic flight patterns for the proposed air carriers, as well as the preparation efforts of military operations and benefits of such a system during combat support missions were investigated. The results of the conceptual study showed that a proposed remote controlled helicopter drone could meet the stated German MOD scanning requirements of mine barriers. Fixed wing air carriers were at a definite disadvantage because of their inherently large turning loops. By implementing a mine detection system like AMiDS minefields can be reconnoitered before an attack. It is therefore possible either to plan, how the minefields can be circumvented or where precisely breaching lanes through the mine barriers are to be cleared for the advancing force.

  7. Early Detection of Autism Spectrum Disorder in Young isiZulu-Speaking Children in South Africa

    ERIC Educational Resources Information Center

    Chambers, Nola J.; Wetherby, Amy M.; Stronach, Sheri T.; Njongwe, Nonyameko; Kauchali, Shuaib; Grinker, Richard R.

    2017-01-01

    Culturally appropriate tools are needed for detecting symptoms of autism spectrum disorder in young South African children. The objectives of this study were to (1) adapt and translate into isiZulu existing measures for detecting early signs of autism spectrum disorder, (2) use the measures to characterize and compare behavioural profiles of young…

  8. The Effect of Early Visual Deprivation on the Development of Face Detection

    ERIC Educational Resources Information Center

    Mondloch, Catherine J.; Segalowitz, Sidney J.; Lewis, Terri L.; Dywan, Jane; Le Grand, Richard; Maurer, Daphne

    2013-01-01

    The expertise of adults in face perception is facilitated by their ability to rapidly detect that a stimulus is a face. In two experiments, we examined the role of early visual input in the development of face detection by testing patients who had been treated as infants for bilateral congenital cataract. Experiment 1 indicated that, at age 9 to…

  9. Sampling design for early detection of aquatic invasive species in Great Lakes ports

    EPA Science Inventory

    We evaluated a pilot adaptive monitoring program for aquatic invasive species (AIS) early detection in Lake Superior. The monitoring program is designed to detect newly-introduced fishes, and encompasses the lake’s three major ports (Duluth-Superior, Sault Ste. Marie, Thund...

  10. Sampling design for aquatic invasive species early detection in Great Lakes ports

    EPA Science Inventory

    From 2006-2012, we evaluated a pilot aquatic invasive species (AIS) early detection monitoring program in Lake Superior that was designed to detect newly introduced fishes. We established survey protocols for three major ports (Duluth-Superior, Sault Ste. Marie, Thunder Bay) and ...

  11. Early detection monitoring of aquatic invasive species: Measuring performance success in a Lake Superior pilot network

    EPA Science Inventory

    The Great Lakes Water Quality Agreement, Annex 6 calls for a U.S.-Canada, basin-wide aquatic invasive species early detection network by 2015. The objective of our research is to explore survey design strategies that can improve detection efficiency, and to develop performance me...

  12. Early Detection Monitoring Approaches for Exotic Aquatic Species in Great Lakes Harbors and Embayments

    EPA Science Inventory

    Aquatic invasive species pose a significant ecological and economic threat in the Great Lakes basin. Early detection of invaders is desirable so as to allow for a timely management response, raising the question of how to accomplish this detection in a consistent, cost-effective...

  13. Early Detection Rapid Response Program Targets New Noxious Weed Species in Washington State

    ERIC Educational Resources Information Center

    Andreas, Jennifer E.; Halpern, Alison D.; DesCamp, Wendy C.; Miller, Timothy W.

    2015-01-01

    Early detection, rapid response is a critical component of invasive plant management. It can be challenging, however, to detect new invaders before they become established if landowners cannot identify species of concern. In order to increase awareness, eye-catching postcards were developed in Washington State as part of a noxious weed educational…

  14. Early detection of crop injury from herbicide glyphosate by leaf biochemical parameter inversion

    Early detection of crop injury from glyphosate is of significant importance in crop management. In this paper, we attempt to detect glyphosate-induced crop injury by PROSPECT (leaf optical PROperty SPECTra model) inversion through leaf hyperspectral reflectance measurements for non-Glyphosate-Resist...

  15. Experiences integrating autonomous components and legacy systems into tsunami early warning systems

    NASA Astrophysics Data System (ADS)

    Reißland, S.; Herrnkind, S.; Guenther, M.; Babeyko, A.; Comoglu, M.; Hammitzsch, M.

    2012-04-01

    Fostered by and embedded in the general development of Information and Communication Technology (ICT) the evolution of Tsunami Early Warning Systems (TEWS) shows a significant development from seismic-centred to multi-sensor system architectures using additional sensors, e.g. sea level stations for the detection of tsunami waves and GPS stations for the detection of ground displacements. Furthermore, the design and implementation of a robust and scalable service infrastructure supporting the integration and utilisation of existing resources serving near real-time data not only includes sensors but also other components and systems offering services such as the delivery of feasible simulations used for forecasting in an imminent tsunami threat. In the context of the development of the German Indonesian Tsunami Early Warning System (GITEWS) and the project Distant Early Warning System (DEWS) a service platform for both sensor integration and warning dissemination has been newly developed and demonstrated. In particular, standards of the Open Geospatial Consortium (OGC) and the Organization for the Advancement of Structured Information Standards (OASIS) have been successfully incorporated. In the project Collaborative, Complex, and Critical Decision-Support in Evolving Crises (TRIDEC) new developments are used to extend the existing platform to realise a component-based technology framework for building distributed TEWS. This talk will describe experiences made in GITEWS, DEWS and TRIDEC while integrating legacy stand-alone systems and newly developed special-purpose software components into TEWS using different software adapters and communication strategies to make the systems work together in a corporate infrastructure. The talk will also cover task management and data conversion between the different systems. Practical approaches and software solutions for the integration of sensors, e.g. providing seismic and sea level data, and utilisation of special

  16. Remote health monitoring system for detecting cardiac disorders.

    PubMed

    Bansal, Ayush; Kumar, Sunil; Bajpai, Anurag; Tiwari, Vijay N; Nayak, Mithun; Venkatesan, Shankar; Narayanan, Rangavittal

    2015-12-01

    Remote health monitoring system with clinical decision support system as a key component could potentially quicken the response of medical specialists to critical health emergencies experienced by their patients. A monitoring system, specifically designed for cardiac care with electrocardiogram (ECG) signal analysis as the core diagnostic technique, could play a vital role in early detection of a wide range of cardiac ailments, from a simple arrhythmia to life threatening conditions such as myocardial infarction. The system that the authors have developed consists of three major components, namely, (a) mobile gateway, deployed on patient's mobile device, that receives 12-lead ECG signals from any ECG sensor, (b) remote server component that hosts algorithms for accurate annotation and analysis of the ECG signal and (c) point of care device of the doctor to receive a diagnostic report from the server based on the analysis of ECG signals. In the present study, their focus has been toward developing a system capable of detecting critical cardiac events well in advance using an advanced remote monitoring system. A system of this kind is expected to have applications ranging from tracking wellness/fitness to detection of symptoms leading to fatal cardiac events.

  17. Early diagnostic role of PSA combined miR-155 detection in prostate cancer.

    PubMed

    Guo, T; Wang, X-X; Fu, H; Tang, Y-C; Meng, B-Q; Chen, C-H

    2018-03-01

    As a kind of malignant tumor in the male genitourinary system, prostate cancer exhibits significantly increased occurrence. Prostate-specific antigen (PSA) expression can be seen in the prostate cancer, prostatitis, and other diseases, therefore, lack of diagnostic specificity. The miR-155 expression is abnormally increased in the tumors. Therefore, this study aims to explore the clinical significance of PSA combined miR-155 detection in the early diagnosis of prostate cancer. A total of 86 patients diagnosed with prostate cancer were enrolled in this study. PSA and miR-155 gene expression in tumor tissue were detected by using Real-time PCR. The serum levels of PSA were measured by using enzyme-linked immunosorbent assay (ELISA). The correlation of PSA and miR-155 expression with age, body mass index (BMI), tumor volume, tumor-node-metastasis (TNM) stage, lymph node metastasis (LNM), and other clinicopathological features were analyzed, respectively. Serum PSA expression and PSA gene in tumor tissue were significantly higher compared to that in adjacent tissues (p<0.05). PSA gene and protein increased significantly with the clinical stage of TNM and decreased following the increase of grade (p<0.05). The miR-155 level was significantly elevated in the tumor tissue compared with para-carcinoma tissue (p<0.05). PSA and miR-155 expressions were positively correlated with TNM stage, tumor volume, and LNM, and negatively correlated with grade (p<0.05). PSA and miR-155 were closely related to the clinicopathological features of prostate cancer. Combined detection is helpful for the early diagnosis of prostate cancer.

  18. Monitoring cow activity and rumination time for an early detection of heat stress in dairy cow

    NASA Astrophysics Data System (ADS)

    Abeni, Fabio; Galli, Andrea

    2017-03-01

    The aim of this study was to explore the use of cow activity and rumination time by precision livestock farming tools as early alert for heat stress (HS) detection. A total of 58 Italian Friesian cows were involved in this study during summer 2015. Based on the temperature humidity index (THI), two different conditions were compared on 16 primiparous and 11 multiparous, to be representative of three lactation phases: early (15-84 DIM), around peak (85-154 DIM), and plateau (155-224 DIM). A separate dataset for the assessment of the variance partition included all the cows in the herd from June 7 to July 16. The rumination time (RT2h, min/2 h) and activity index (AI2h, bouts/2 h) were summarized every 2-h interval. The raw data were used to calculate the following variables: total daily RT (RTt), daytime RT (RTd), nighttime RT (RTn), total daily AI (AIt), daytime AI (AId), and nighttime AI (AIn). Either AIt and AId increased, whereas RTt, RTd, and RTn decreased with higher THI in all the three phases. The highest decrease was recorded for RTd and ranged from 49 % (early) to 45 % (plateau). The contribution of the cow within lactation phase was above 60 % of the total variance for AI traits and a share from 33.9 % (for RTt) to 54.8 % (RTn) for RT traits. These observations must be extended to different feeding managements and different animal genetics to assess if different thresholds could be identified to set an early alert system for the farmer.

  19. Monitoring cow activity and rumination time for an early detection of heat stress in dairy cow.

    PubMed

    Abeni, Fabio; Galli, Andrea

    2017-03-01

    The aim of this study was to explore the use of cow activity and rumination time by precision livestock farming tools as early alert for heat stress (HS) detection. A total of 58 Italian Friesian cows were involved in this study during summer 2015. Based on the temperature humidity index (THI), two different conditions were compared on 16 primiparous and 11 multiparous, to be representative of three lactation phases: early (15-84 DIM), around peak (85-154 DIM), and plateau (155-224 DIM). A separate dataset for the assessment of the variance partition included all the cows in the herd from June 7 to July 16. The rumination time (RT2h, min/2 h) and activity index (AI2h, bouts/2 h) were summarized every 2-h interval. The raw data were used to calculate the following variables: total daily RT (RTt), daytime RT (RTd), nighttime RT (RTn), total daily AI (AIt), daytime AI (AId), and nighttime AI (AIn). Either AIt and AId increased, whereas RTt, RTd, and RTn decreased with higher THI in all the three phases. The highest decrease was recorded for RTd and ranged from 49 % (early) to 45 % (plateau). The contribution of the cow within lactation phase was above 60 % of the total variance for AI traits and a share from 33.9 % (for RTt) to 54.8 % (RTn) for RT traits. These observations must be extended to different feeding managements and different animal genetics to assess if different thresholds could be identified to set an early alert system for the farmer.

  20. Multispectral fluorescence imaging of human ovarian and Fallopian tube tissue for early stage cancer detection

    NASA Astrophysics Data System (ADS)

    Tate, Tyler; Baggett, Brenda; Rice, Photini; Watson, Jennifer; Orsinger, Gabe; Nymeyer, Ariel C.; Welge, Weston A.; Keenan, Molly; Saboda, Kathylynn; Roe, Denise J.; Hatch, Kenneth; Chambers, Setsuko; Black, John; Utzinger, Urs; Barton, Jennifer

    2015-03-01

    With early detection, five year survival rates for ovarian cancer are over 90%, yet no effective early screening method exists. Emerging consensus suggests that perhaps over 50% of the most lethal form of the disease, high grade serous ovarian cancer, originates in the Fallopian tube. Cancer changes molecular concentrations of various endogenous fluorophores. Using specific excitation wavelengths and emissions bands on a Multispectral Fluorescence Imaging (MFI) system, spatial and spectral data over a wide field of view can be collected from endogenous fluorophores. Wavelength specific reflectance images provide additional information to normalize for tissue geometry and blood absorption. Ratiometric combination of the images may create high contrast between neighboring normal and abnormal tissue. Twenty-six women undergoing oophorectomy or debulking surgery consented the use of surgical discard tissue samples for MFI imaging. Forty-nine pieces of ovarian tissue and thirty-two pieces of Fallopian tube tissue were collected and imaged with excitation wavelengths between 280 nm and 550 nm. After imaging, each tissue sample was fixed, sectioned and HE stained for pathological evaluation. Comparison of mean intensity values between normal, benign, and cancerous tissue demonstrate a general trend of increased fluorescence of benign tissue and decreased fluorescence of cancerous tissue when compared to normal tissue. The predictive capabilities of the mean intensity measurements are tested using multinomial logistic regression and quadratic discriminant analysis. Adaption of the system for in vivo Fallopian tube and ovary endoscopic imaging is possible and is briefly described.