Sample records for early open angle

  1. [Thinking about the present primary open angle glaucoma early diagnosis concepts and methods].

    PubMed

    Ren, Zeqin

    2014-05-01

    Early diagnosis of primary open-angle glaucoma has not been clear and consistent in concepts and methods. At present, according to the pathophysiology process of optic nerve damage and its detection technology, early diagnosis on the concept still belongs to the early clinical diagnosis instead of preclinical diagnosis, and on the method depends on the fundus as morphological index combined with the visual field as functional index. The direction of early clinical diagnosis mainly lies in exploring more effective diagnosis index, rather than blindly adopt new diagnostic technology.

  2. Progressive Decrease of Peripapillary Angioflow Vessel Density During Structural and Visual Field Progression in Early Primary Open-angle Glaucoma.

    PubMed

    Holló, Gábor

    2017-07-01

    To present a case of early primary open-angle glaucoma in which retinal nerve fiber layer thickness (RNFLT), ganglion cell complex (GCC), and visual field progression were accompanied with significant progression of peripapillary angioflow vessel density (PAFD) measured with optical coherence tomographic angiography. A 68-year-old female patient who was under topical intraocular pressure (IOP) lowering medication for 20 years for ocular hypertension of the right and preperimetric primary open-angle glaucoma of the left eye (with reproducible inferotemporal and superotemporal neuroretinal rim and RNFL loss) was prospectively imaged with the AngioVue OCT for RNFLT, GCC thickness, and PAFD, and investigated with the Octopus Normal G2 visual field test on the same days at 6-month intervals for 18 months, while the IOP of the left eye escaped from control. IOP of the left eye fluctuated between 14 and 30 mm Hg in the study period. RNFLT, GCC thickness, and peripapillary PAFD all decreased significantly (linear regression analysis, P=0.030, 0.040, and 0.020, respectively), and a significant 2.1 dB/y progression was seen for a superior visual field cluster. The RNFLT, peripapillary PAFD, and visual field of the right eye remained normal and unchanged. In our case IOP elevation, glaucomatous visual field conversion, and structural progression were accompanied with significant progressive decrease of peripapillary PAFD. The simultaneous thinning of RNFLT and GCC and decrease of peripapillary PAFD suggest that PAFD may potentially be an additional indicator of early progression in primary open-angle glaucoma.

  3. Biomarkers in primary open angle glaucoma.

    PubMed

    Kokotas, Haris; Kroupis, Christos; Chiras, Dimitrios; Grigoriadou, Maria; Lamnissou, Klea; Petersen, Michael B; Kitsos, George

    2012-12-01

    Glaucoma, a leading cause of blindness worldwide, is currently defined as a disturbance of the structural or functional integrity of the optic nerve that causes characteristic atrophic changes in the optic nerve, which may lead to specific visual field defects over time. This disturbance usually can be arrested or diminished by adequate lowering of intraocular pressure (IOP). Glaucoma can be divided roughly into two main categories, ‘ open angle ’ and ‘ closed angle ’ glaucoma.Open angle, chronic glaucoma tends to progress at a slower rate and patients may not notice loss of vision until the disease has progressed significantly. Primary open angle glaucoma(POAG) is described distinctly as a multifactorial optic neuropathy that is chronic and progressive with a characteristic acquired loss of optic nerve fibers. Such loss develops in the presence of open anterior chamber angles, characteristic visual field abnormalities, and IOP that is too high for the healthy eye. It manifests by cupping and atrophy of the optic disc, in the absence of other known causes of glaucomatous disease. Several biological markers have been implicated with the disease. The purpose of this study was to summarize the current knowledge regarding the non-genetic molecular markers which have been predicted to have an association with POAG but have not yet been validated.

  4. Open-angle glaucoma in the Petit Basset Griffon Vendeen.

    PubMed

    Bedford, Peter G C

    2017-03-01

    To report the prevalence and clinical characteristics of an open-angle glaucoma in Petit Basset Griffon Vendeen (PBGV) dogs in the United Kingdom (UK). At breed society clinics extending over a 6-year period, 366 dogs of varying ages and both sexes were clinically examined for signs of glaucoma using slit-lamp biomicroscopy, indirect and direct ophthalmoscopy, tonometry, and gonioscopy. The prevalence of glaucoma was 10.4% (38 dogs). Clinical signs of the disease presented from 3 years of age onwards, the commonest initial feature being the elevation of intraocular pressure (IOP) in 15 dogs (39.4%). In addition to elevated IOP, another 13 dogs (34.2%) presented with other features of glaucoma, some with lens subluxation and globe enlargement and all with possible or known vision defects. In the remaining 10 dogs (26.3%), phacodonesis or lens subluxation was observed before subsequent elevation of IOP. High prevalence and similarity to the primary open-angle glaucoma (POAG) seen in the Beagle and Elkhound breeds indicate that an open-angle glaucoma is present in the PBGV in the UK and that this disease may be genetically determined in this breed. Although increased IOP is the commonest early diagnostic feature, lens instability prior to an increase in IOP may be part of the clinical picture. © 2016 American College of Veterinary Ophthalmologists.

  5. Undetected angle closure in patients with a diagnosis of open-angle glaucoma.

    PubMed

    Varma, Devesh K; Simpson, Sarah M; Rai, Amandeep S; Ahmed, Iqbal Ike K

    2017-08-01

    The aim of this study was to identify the proportion of patients referred to a tertiary glaucoma centre with a diagnosis of open-angle glaucoma (OAG) who were found to have angle closure glaucoma. Retrospective chart review. Consecutive new patients referred for glaucoma management to a tertiary centre between July 2010 and December 2011 were reviewed. Patients whose referrals for glaucoma assessment specified angle status as "open" were included. The data collected included glaucoma specialist's angle assessment, diagnosis, and glaucoma severity. The status of those with 180 degrees or more Shaffer angle grading of 0 was classified as "closed." From 1234 glaucoma referrals, 179 cases were specified to have a diagnosis of OAG or when angles were known to be open. Of these, 16 (8.9%) were found on examination by the glaucoma specialist to have angle closure. Pseudoexfoliation was present in 4 of 16 patients (25%) in the missed angle-closure glaucoma (ACG) group and 22 of 108 patients (13.5%) in the remaining OAG group. There was no difference found in demographic or ocular biometric parameters between those with confirmed OAG versus those with missed ACG. Almost 1 in 11 patients referred by ophthalmologists to a tertiary glaucoma centre with a diagnosis of OAG were in fact found to have angle closure. Given the different treatment approaches for ACG versus OAG, this study suggests a need to strengthen angle evaluations. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  6. Peripapillary schisis in open-angle glaucoma.

    PubMed

    Dhingra, N; Manoharan, R; Gill, S; Nagar, M

    2017-03-01

    PurposeTo report clinical features, topographic findings and outcome of 10 eyes with peripapillary schisis in open-angle glaucoma.Patients and methodsA retrospective review of patients with open-angle glaucoma who were noted to have peripapillary schisis on optical coherence tomography (OCT) were included. Serial peripapillary and macula infrared and OCT images, visual acuity, visual fields, and schisis appearance were reviewed.ResultsTen eyes of nine patients with open-angle glaucoma were detected to have the presence of peripapillary schisis. Nerve fibre layer schisis was detected in all eyes and one eye had an associated macular schisis. None of the eyes had an acquired pit of the optic nerve or pathological myopia. The mean intraocular pressures at detection was 18.3±4.3 mm Hg and the schisis resolved in four eyes after a mean follow-up of 21.2±8.8 months. Visual field worsening was noted in 4 of the 10 eyes and the resolution of schisis resulted in significant reduction in the retinal nerve fibre layer (RNFL) thickness.ConclusionsPeripapillary schisis detected during the normal course of open-angle glaucoma can resolve spontaneously and rarely involves the macula. Its resolution leads to reduction in RNFL thickness; therefore, caution is advised while interpreting serial scans.

  7. Lamina cribrosa position and Bruch's membrane opening differences between anterior ischemic optic neuropathy and open-angle glaucoma.

    PubMed

    Rebolleda, Gema; Pérez-Sarriegui, Ane; Díez-Álvarez, Laura; De Juan, Victoria; Muñoz-Negrete, Francisco J

    2018-06-01

    To compare the optic nerve head morphology among primary open-angle glaucoma, non-arteritic anterior ischemic optic neuropathy eyes, their fellow healthy eyes and control eyes, using spectral-domain optical coherence tomography with enhanced depth imaging. Observational cross-sectional study including 88 eyes of 68 patients. In this study, 23 non-arteritic anterior ischemic optic neuropathy eyes, 17 fellow unaffected eyes, 25 primary open-angle glaucoma eyes, and 23 age-matched control eyes were included. Peripapillary retinal nerve fiber layer thickness and optic disk area were evaluated. Bruch's membrane opening diameter, optic cup depth, anterior lamina cribrosa depth, and prelaminar tissue thickness were assessed. Non-arteritic anterior ischemic optic neuropathy and primary open-angle glaucoma eyes had similar visual field mean deviation and peripapillary retinal nerve fiber layer thickness (P = 0.6 and P = 0.56, respectively). Bruch's membrane opening diameter was significantly larger in primary open-angle glaucoma eyes than in control eyes (P = 0.02). Lamina cribrosa and disk cup were deeper in eyes with primary open-angle glaucoma than both control and non-arteritic anterior ischemic optic neuropathy eyes (P < 0.001). Prelaminar tissue thickness was significantly thinner in primary open-angle glaucoma eyes than in non-arteritic anterior ischemic optic neuropathy eyes (P < 0.001). Lamina cribrosa was shallower in both non-arteritic anterior ischemic optic neuropathy and unaffected fellow eyes compared to healthy eyes (P < 0.001 and P = 0.04, respectively). No differences were found in the optic disk area. A forward lamina cribrosa placement and not a smaller disk could be involved in the pathogenesis of non-arteritic anterior ischemic optic neuropathy. A significantly larger Bruch's membrane opening diameter was found in primary open-angle glaucoma eyes compared with control eyes. This issue has clinical implications because Bruch

  8. A Generalized Maxwell Model for Creep Behavior of Artery Opening Angle

    PubMed Central

    Zhang, W.; Guo, X.; Kassab, G. S.

    2009-01-01

    An artery ring springs open into a sector after a radial cut. The opening angle characterizes the residual strain in the unloaded state, which is fundamental to understanding stress and strain in the vessel wall. A recent study revealed that the opening angle decreases with time if the artery is cut from the loaded state, while it increases if the cut is made from the no-load state due to viscoelasticity. In both cases, the opening angle approaches the same value in 3 hours. This implies that the characteristic relaxation time is about 10,000 sec. Here, the creep function of a generalized Maxwell model (a spring in series with six Voigt bodies) is used to predict the temporal change of opening angle in multiple time scales. It is demonstrated that the theoretical model captures the salient features of the experimental results. The proposed creep function may be extended to study the viscoelastic response of blood vessels under various loading conditions. PMID:19045526

  9. Auditory processing deficits in individuals with primary open-angle glaucoma.

    PubMed

    Rance, Gary; O'Hare, Fleur; O'Leary, Stephen; Starr, Arnold; Ly, Anna; Cheng, Belinda; Tomlin, Dani; Graydon, Kelley; Chisari, Donella; Trounce, Ian; Crowston, Jonathan

    2012-01-01

    The high energy demand of the auditory and visual pathways render these sensory systems prone to diseases that impair mitochondrial function. Primary open-angle glaucoma, a neurodegenerative disease of the optic nerve, has recently been associated with a spectrum of mitochondrial abnormalities. This study sought to investigate auditory processing in individuals with open-angle glaucoma. DESIGN/STUDY SAMPLE: Twenty-seven subjects with open-angle glaucoma underwent electrophysiologic (auditory brainstem response), auditory temporal processing (amplitude modulation detection), and speech perception (monosyllabic words in quiet and background noise) assessment in each ear. A cohort of age, gender and hearing level matched control subjects was also tested. While the majority of glaucoma subjects in this study demonstrated normal auditory function, there were a significant number (6/27 subjects, 22%) who showed abnormal auditory brainstem responses and impaired auditory perception in one or both ears. The finding that a significant proportion of subjects with open-angle glaucoma presented with auditory dysfunction provides evidence of systemic neuronal susceptibility. Affected individuals may suffer significant communication difficulties in everyday listening situations.

  10. Myocardial infarction increases progressive visual field defects in well treated early primary open angle glaucoma--a prospective case control study.

    PubMed

    Mondal, Lakshmikanta; Baidya, Krishnapada; Choudhury, Himadri; Roy, Rupam

    2013-06-01

    The purpose of the study was to evaluate the progression of glaucomatous field damage in patients with stable primary open angle glaucoma after an attack of myocardial infarction. In this case control study, 62 open angle glaucoma patients were selected and regularly followed up. Among 62 patients, 9 had an attack of myocardial infarction. The intra-ocular pressure and visual field progression of both the groups (myocardial infarction versus no myocardial infarction) were analysed. Three (33.3%) out of 9 patients who had suffered from myocardial infarction showed progressive visual field loss whereas only 9 (16.9%) out of 53 patients who did not suffer from myocardial infarction, showed progressive field changes. Both the groups had stable target intra-ocular pressure between 14 and 16 mm Hg. Myocardial infarction may adversely influence the progression of primary open angle glaucoma which is suspected to result from ischaemia induced neuronal loss and only control of intraocular pressure is not the only solution. We have to look for other drugs that prevents ischaemia induced neuronal damage.

  11. The distinction between juvenile and adult-onset primary open-angle glaucoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiggs, J.L.; Haines, J.L.; Damji, K.F.

    1996-01-01

    Because of the significant differences between the juvenile and adult forms of open-angle glaucoma, especially with regard to inheritance, prevalence, severity, and age of onset, we read with interest the recent publication by Morissette et al., describing a pedigree with a phenotype that overlaps the distinctive features of juvenile-onset open-angle glaucoma (JOAG) and adult-onset primary open-angle glaucoma (usually abbreviated as POAG or COAG). These authors conclude that a gene mapped to human chromosome 1q21-q31 (GLC1A) can be responsible for both juvenile and adult forms of open-angle glaucoma. The implications of such a result could be extremely important, in light ofmore » the high prevalence of the adult form of the disease. However, while the data presented in this report suggest that variable expressivity of the GLC1A gene may lead to a broader range of onset for this form of juvenile glaucoma, these data do not identify the GLC1A gene as an important cause of POAG. To prevent misleading interpretations of this and similar studies, we wish to clarify the distinction between the juvenile and adult forms of open-angle glaucoma. 8 refs.« less

  12. Obstructive sleep apnoea syndrome in patients with primary open-angle glaucoma.

    PubMed

    Balbay, Ege G; Balbay, Oner; Annakkaya, Ali N; Suner, Kezban O; Yuksel, Harun; Tunç, Murat; Arbak, Peri

    2014-10-01

    To investigate the prevalence of obstructive sleep apnoea syndrome in patients with primary open-angle glaucoma. Case series. School of Medicine, Düzce University, Turkey. Twenty-one consecutive primary open-angle glaucoma patients (12 females and 9 males) who attended the out-patient clinic of the Department of Ophthalmology between July 2007 and February 2008 were included in this study. All patients underwent polysomnographic examination. The prevalence of obstructive sleep apnoea syndrome was 33.3% in patients with primary open-angle glaucoma; the severity of the condition was mild in 14.3% and moderate in 19.0% of the subjects. The age (P=0.047) and neck circumference (P=0.024) in patients with obstructive sleep apnoea syndrome were significantly greater than those without the syndrome. Triceps skinfold thickness in glaucomatous obstructive sleep apnoea syndrome patients reached near significance versus those without the syndrome (P=0.078). Snoring was observed in all glaucoma cases with obstructive sleep apnoea syndrome. The intra-ocular pressure of patients with primary open-angle glaucoma with obstructive sleep apnoea syndrome was significantly lower than those without obstructive sleep apnoea syndrome (P=0.006 and P=0.035 for the right and left eyes, respectively). There was no significant difference in the cup/disc ratio and visual acuity, except visual field defect, between primary open-angle glaucoma patients with and without obstructive sleep apnoea syndrome. Although it does not provide evidence for a cause-effect relationship, high prevalence of obstructive sleep apnoea syndrome in patients with primary open-angle glaucoma in this study suggests the need to explore the long-term results of coincidence, relationship, and cross-interaction of these two common disorders.

  13. Early Clinical Results of a Novel Ab Interno Gel Stent for the Surgical Treatment of Open-angle Glaucoma.

    PubMed

    Sheybani, Arsham; Dick, H Burkhard; Ahmed, Iqbal I K

    2016-07-01

    To evaluate the intraocular pressure (IOP) lowering effect of the XEN140 microfistula gel stent implant for the surgical treatment of open-angle glaucoma. Forty-nine eyes of 49 patients with an IOP>18 mm Hg and ≤35 mm Hg were studied in a prospective nonrandomized multicenter cohort trial of the surgical implantation of the XEN140 implant in patients with open-angle glaucoma. Complete success was defined as a postoperative IOP≤18 mm Hg with ≥20% reduction in IOP at 12 months without any glaucoma medications. Failure was defined as vision loss of light perceptions vision or worse, need for additional glaucoma surgery, or <20% reduction of IOP from baseline. The average age was 64.3 (28.1 to 86.9) years old. Twenty-one eyes had prior failed trabeculectomy with mitomycin C surgery. IOP at 12 months decreased from a mean of 23.1 (±4.1) mm Hg to 14.7 (±3.7) mm Hg for a 36.4% reduction in IOP from baseline. The number of patients at 12 months who achieved an IOP≤18 mm Hg and ≥20% reduction in IOP was 40 (89%). The number of patients who achieved an IOP≤18 mm Hg and ≥20% reduction in IOP without antiglaucoma medications was 18 (40%). The XEN140 gel stent lowers IOP with few complications when implanted for the surgical treatment of open-angle glaucoma.

  14. Diagnostic capability of scanning laser polarimetry with variable cornea compensator in Indian patients with early primary open-angle glaucoma.

    PubMed

    Parikh, Rajul S; Parikh, Shefali R; Kumar, Rajesh S; Prabakaran, S; Babu, J Gansesh; Thomas, Ravi

    2008-07-01

    To evaluate the diagnostic ability of scanning laser polarimetry (GDx variable corneal compensator [VCC]) for early glaucoma in Asian Indian eyes. Cross-sectional observational study. Two groups of patients (early glaucoma and normal) who satisfied the inclusion and exclusion criteria were included. Early glaucoma was diagnosed in presence of open angles, characteristic glaucomatous optic disc changes correlating with the visual field (VF) on automated perimetry (VF defect fulfilling at least 2 of 3 Anderson and Patella's criteria with mean deviation >or= -6 decibels). Normal subjects had visual acuity >or= 20/30 and intraocular pressure < 22 mmHg, with a normal optic disc and fields and no ocular abnormality. All patients underwent complete ophthalmic evaluation, including VF examination (24-2/30-2 Swedish interactive threshold algorithm standard program) and imaging with GDx VCC. Sensitivity, specificity, positive predictive value and negative predictive value, area under the receiving operating characteristic curve, and likelihood ratios (LRs) were calculated for various GDx VCC parameters. Seventy-four eyes (74 patients) with early glaucoma and 104 eyes (104 normal subjects) were enrolled. TSNIT Std Dev (temporal-superior-nasal-inferior-temporal standard deviation) had the best combination of sensitivity and specificity-61.3 and 95.2, respectively-followed by nerve fiber index score > 50 (sensitivity, 52.7%; specificity, 99%). Nerve fiber index score > 50 had positive and negative predictive values of 74.3% and 97.6%, respectively, for an assumed glaucoma prevalence of 5%. Nerve fiber index score > 50 had a positive LR (+LR) of 54.8 for early glaucoma. GDx VCC has moderate sensitivity, with high specificity, in the diagnosis of early glaucoma. The high +LR for the nerve fiber index score can provide valuable diagnostic information for individual patients.

  15. Linkage studies in primary open angle glaucoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Avramopoulos, D.; Grigoriadu, M.; Kitsos, G.

    1994-09-01

    Glaucoma is a leading cause of blindness worldwide. The majority of glaucoma is associated with an open, normal appearing anterior chamber angle and is termed primary open angle glaucoma (POAG, MIM 137760). It is characterized by elevated intraocular pressure and onset in middle age or later. A subset of POAG with juvenile onset has recently been linked to chromosome 1q in two families with autosomal dominant inheritance. Eleven pedigrees with autosomal dominant POG (non-juvenile-onset) have been identified in Epirus, Greece. In the present study DNA samples have been collected from 50 individuals from one large pedigree, including 12 affected individuals.more » Preliminary results of linkage analysis with chromosome 1 microsatellites using the computer program package LINKAGE Version 5.1 showed no linkage with the markers previously linked to juvenile-onset POAG. Further linkage analysis is being pursued, and the results will be presented.« less

  16. [Basic and clinical studies of pressure-independent damaging factors of open angle glaucoma].

    PubMed

    Araie, Makoto

    2011-03-01

    reaction to it were also found, similar to the mice experiments. In living monkeys the glial reaction in the LGN could be observed by means of positron emission tomography. 7. In the LGN of monkeys with experimental high IOP glaucoma, the M-cell system was preferentially damaged in the early stage, while in the later stages both the M- and P-cell systems were damaged. 8. In a single-instituted prospective double-blinded clinical trial, oral administration of nilvadipine at 4 mg/day, a DHP calcium-channel blocker, was found to significantly retard the visual field progression in normal tension glaucoma patients over 3 years, while significantly increasing the choroidal and optic nerve blood flow by about 35%. 9. A multi-instituted prospective double-blinded clinical trial in normal tension glaucoma patients revealed that the rate of MD deterioration under monotherapy with either topical nipradilol or timolol was around -0.05 dB/year, thought to be considerably slower than -0.25 dB/year, the commonly estimated rate of MD deterioration by pressure-independent damaging factors. The current results indicate the possibility of treatment of pressure-independent damaging factors of open-angle glaucoma in Japanese open-angle glaucoma patients with oral nilvadipine and topical anti-glaucoma agents.

  17. MOJAVE - XIV. Shapes and opening angles of AGN jets

    NASA Astrophysics Data System (ADS)

    Pushkarev, A. B.; Kovalev, Y. Y.; Lister, M. L.; Savolainen, T.

    2017-07-01

    We present 15 GHz stacked VLBA images of 373 jets associated with active galactic nuclei (AGNs) having at least five observing epochs within a 20 yr time interval 1994-2015 from the Monitoring Of Jets in Active galactic nuclei with VLBA Experiments (MOJAVE) programme and/or its precursor, the 2-cm VLBA Survey. These data are supplemented by 1.4 GHz single-epoch VLBA observations of 135 MOJAVE AGNs to probe larger scale jet structures. The typical jet geometry is found to be close to conical on scales from hundreds to thousands of parsecs, while a number of galaxies show quasi-parabolic streamlines on smaller scales. A true jet geometry in a considerable fraction of AGNs appears only after stacking epochs over several years. The jets with significant radial accelerated motion undergo more active collimation. We have analysed total intensity jet profiles transverse to the local jet ridgeline and derived both apparent and intrinsic opening angles of the flows, with medians of 21.5° and 1.3°, respectively. The Fermi LAT-detected gamma-ray AGNs in our sample have, on average, wider apparent and narrower intrinsic opening angle, and smaller viewing angle than non-LAT-detected AGNs. We have established a highly significant correlation between the apparent opening angle and gamma-ray luminosity, driven by Doppler beaming and projection effects.

  18. Open-angle glaucoma in patients with diabetic retinopathy at the Puerto Rico Medical Center.

    PubMed

    Cruz-lñigo, Yousef; Izquierdo, Natalio J; García, Omar; Pérez, Raúl

    2012-01-01

    The association of open-angle glaucoma (OAG) with diabetes mellitus remains controversial. We report on the frequency of open-angle glaucoma in patients having diabetic retinopathy in a population of the Puerto Rico Medical Center. A cross-sectional study of 1,442 patients was done. Only the chart of patients 40 years-of-age and older, with a diagnosis of diabetic retinopathy and/or open-angle glaucoma were included. Descriptive analysis was done. Unadjusted and gender-adjusted logistic regression analyses were used to estimate risk of developing open-angle glaucoma in patients with diabetic retinopathy for each subsequent decade. 1,040 patients were diagnosed with diabetic retinopathy from July 1, 2004 to June 30, 2009. Also, 402 patients were diagnosed with open-angle glaucoma from July 1, 2007 to June 30, 2009. Of the 1,040 patients with diabetic retinopathy, 64 patients (6.15%) also had OAG. According to our gender-adjusted logistic regression analysis the estimated risk of developing open-angle glaucoma for patients 40 years-of-age with diabetic retinopathy increased for each subsequent decade until the seventh decade, odds ratio = 5.07 (95% confidence interval: 1.62-15.86). Thereafter, it decreased, odds ratio = 2.07 (95% confidence interval: 0.36-11.82). Our findings suggest that Puerto Rico patients between 40 to 79 years of age with diabetic retinopathy have an increased risk of developing open-angle glaucoma with each subsequent decade. Screening for open-angle glaucoma in patients with diabetic retinopathy is of utmost importance in the aging Puerto Rico population to prevent blindness.

  19. On the evolution of jet energy and opening angle in strongly coupled plasma

    NASA Astrophysics Data System (ADS)

    Chesler, Paul M.; Rajagopal, Krishna

    2016-05-01

    We calculate how the energy and the opening angle of jets in {N} = 4 SYM theory evolve as they propagate through the strongly coupled plasma of that theory. We define the rate of energy loss dE jet /dx and the jet opening angle in a straightforward fashion directly in the gauge theory before calculating both holographically, in the dual gravitational description. In this way, we rederive the previously known result for dE jet /dx without the need to introduce a finite slab of plasma. We obtain a striking relationship between the initial opening angle of the jet, which is to say the opening angle that it would have had if it had found itself in vacuum instead of in plasma, and the thermalization distance of the jet. Via this relationship, we show that {N} = 4 SYM jets with any initial energy that have the same initial opening angle and the same trajectory through the plasma experience the same fractional energy loss. We also provide an expansion that describes how the opening angle of the {N} = 4 SYM jets increases slowly as they lose energy, over the fraction of their lifetime when their fractional energy loss is not yet large. We close by looking ahead toward potential qualitative lessons from our results for QCD jets produced in heavy collisions and propagating through quark-gluon plasma.

  20. On the evolution of jet energy and opening angle in strongly coupled plasma

    DOE PAGES

    Chesler, Paul M.; Rajagopal, Krishna

    2016-05-17

    We calculate how the energy and the opening angle of jets in N = 4SYM theory evolve as they propagate through the strongly coupled plasma of that theory. We define the rate of energy loss dE jet/dx and the jet opening angle in a straightforward fashion directly in the gauge theory before calculating both holographically, in the dual gravitational description. In this way, we rederive the previously known result for dE jet/dx without the need to introduce a finite slab of plasma. We obtain a striking relationship between the initial opening angle of the jet, which is to say themore » opening angle that it would have had if it had found itself in vacuum instead of in plasma, and the thermalization distance of the jet. Via this relationship, we show that N = 4SYM jets with any initial energy that have the same initial opening angle and the same trajectory through the plasma experience the same fractional energy loss. We also provide an expansion that describes how the opening angle of the N = 4SYM jets increases slowly as they lose energy, over the fraction of their lifetime when their fractional energy loss is not yet large. In conclusion, we close by looking ahead toward potential qualitative lessons from our results for QCD jets produced in heavy collisions and propagating through quark-gluon plasma.« less

  1. Economic impact of primary open-angle glaucoma in Australia.

    PubMed

    Dirani, Mohamed; Crowston, Jonathan G; Taylor, Penny S; Moore, Peter T; Rogers, Sophie; Pezzullo, M Lynne; Keeffe, Jill E; Taylor, Hugh R

    2011-01-01

    Glaucoma is the World's leading cause of irreversible blindness, and poses serious public health and economic concerns.   Review. Published randomized trials and population-based studies since 1985. We report the economic impact of primary open-angle glaucoma and model the effect of changes in detection rates and management strategies. The cost-effectiveness of different interventions to prevent vision loss from primary open-angle glaucoma was measured in terms of financial cost (Australian dollars) and disability-adjusted life years. The prevalence of glaucoma in Australia is expected to increase from 208 000 in 2005 to 379 000 in 2025 because of the aging population. Health system costs over the same time period are estimated to increase from $AU355 million to $AU784 million. Total costs (health system costs, indirect costs and costs of loss of well-being) will increase from $AU1.9 billion to $AU4.3 billion in Australia. Primary open-angle glaucoma poses a significant economic burden, which will increase substantially by 2025. This dynamic model provides a valuable tool for ongoing policy formulation and determining the economic impact of interventions to better prevent visual impairment and blindness from glaucoma. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  2. Visual Disability Among Juvenile Open-angle Glaucoma Patients.

    PubMed

    Gupta, Viney; Ganesan, Vaitheeswaran L; Kumar, Sandip; Chaurasia, Abadh K; Malhotra, Sumit; Gupta, Shikha

    2018-04-01

    Juvenile onset primary open-angle glaucoma (JOAG) unlike adult onset primary open-angle glaucoma presents with high intraocular pressure and diffuse visual field loss, which if left untreated leads to severe visual disability. The study aimed to evaluate the extent of visual disability among JOAG patients presenting to a tertiary eye care facility. Visual acuity and perimetry records of unrelated JOAG patients presenting to our Glaucoma facility were analyzed. Low vision and blindness was categorized by the WHO criteria and percentage impairment was calculated as per the guidelines provided by the American Medical Association (AMA). Fifty-two (15%) of the 348 JOAG patients were bilaterally blind at presentation and 32 (9%) had low vision according to WHO criteria. Ninety JOAG patients (26%) had a visual impairment of 75% or more. Visual disability at presentation among JOAG patients is high. This entails a huge economic burden, given their young age and associated social responsibilities.

  3. Pupillary Responses to Full-Field Chromatic Stimuli Are Reduced in Patients with Early-Stage Primary Open-Angle Glaucoma.

    PubMed

    Najjar, Raymond P; Sharma, Sourabh; Atalay, Eray; Rukmini, Annadata V; Sun, Christopher; Lock, Jing Zhan; Baskaran, Mani; Perera, Shamira A; Husain, Rahat; Lamoureux, Ecosse; Gooley, Joshua J; Aung, Tin; Milea, Dan

    2018-03-21

    To evaluate the ability of chromatic pupillometry to reveal abnormal pupillary responses to light in patients with early-stage primary open-angle glaucoma (POAG) and to test whether the degree of pupillometric impairment correlates with structural hallmarks of optic nerve damage in the disease. Cross-sectional study. Forty-six patients with early-stage POAG (63.4±8.3 years, 63% male, 87% ethnic-Chinese) and 90 age-matched healthy controls (61.4±8.6 years, 34% male, 89% ethnic-Chinese). Patients with POAG had a visual field mean deviation (VFMD) of -6 decibels or better on automated perimetry. Each participant underwent a monocular 2-minute exposure to blue light (462 nm) followed by another 2-minute exposure to red light (638 nm) using a modified Ganzfeld dome equipped with a light-emitting diode lighting system. The light stimuli intensity was increased logarithmically to evaluate the combined extrinsic and intrinsic response of intrinsically photosensitive retinal ganglion cells (ipRGCs). Light-induced changes in horizontal pupil diameter were assessed monocularly using infrared pupillography. Baseline-adjusted, light-induced pupillary constriction amplitudes were calculated, and individual irradiance-response curves were constructed for each stimulus. Pupillary constriction amplitudes were compared between groups and across light intensities using a linear mixed model analysis. The linear relationship between pupillometric parameters and different structural and functional features of glaucoma was assessed using Pearson's correlation analysis. Light-induced pupillary constriction was reduced in patients with early-stage POAG compared with controls at moderate to high irradiances (≥11 Log photons/cm 2 /s) of blue (P = 0.003) and red (P < 0.001) light. Maximal pupillary constriction amplitude was correlated with retinal nerve fiber layer thickness (RNFL) thickness (blue: r = 0.51, P < 0.001; red: r = 0.45, P = 0.002) in patients with POAG but not in

  4. Correlations between Preoperative Angle Parameters and Postoperative Unpredicted Refractive Errors after Cataract Surgery in Open Angle Glaucoma (AOD 500).

    PubMed

    Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun; Seong, Gong Je

    2017-03-01

    To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R²=0.404). Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors.

  5. Correlations between Preoperative Angle Parameters and Postoperative Unpredicted Refractive Errors after Cataract Surgery in Open Angle Glaucoma (AOD 500)

    PubMed Central

    Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun

    2017-01-01

    Purpose To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. Materials and Methods This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. Results In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R2=0.404). Conclusion Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors. PMID:28120576

  6. Retrobulbar hemodynamic parameters in men and women with open angle glaucoma.

    PubMed

    Marjanović, Ivan; Marjanović, Marija; Gvozdenović, Ranko; Risović, Dušica

    2014-12-01

    Several factors may have influence on systemic circulation. Additionally, peripheral circulation also demonstrates sex differences, in young women presenting significantly lower finger blood flow in comparison to men of the same age, a finding that disappears in women after menopause. The aim of this study was to compare the retrobulbar hemodynamic parameters measured by means of color Doppler imaging in women and men with open-angle glaucoma and elevated intraocular pressure. A total of 52 eyes from 52 open-angle glaucoma (OAG) patients, with elevated intraocular pressure (lOP), were included in this cross-sectional study. Peak-systolic velocity (PSV), end-diastolic velocity (EDV), and Pourcelot resistivity index (RI) were assessed in the ophtalmic artery (OA), central retinal artery (CRA), and posterior cilliary arteries (PCA). IOP was measured both with Goldmann Applanation tonometer (GAT) and with the dynamic contour tonometer (DCT), three times respectively. Ocular pulse amplitude (OPA) appeared during the DCT measurement. The retrobulbar hemodynamic parameters did not show any difference between men and post-menopausal women. The results of our study did not find any difference between sexes in patients with open-angle glaucoma and elevated intraocular pressure.

  7. [Dry eye syndrome in patients with primary open-angle glaucoma].

    PubMed

    Boyko, E V; Simakova, I L; Yakushev, D Yu; Ignat'ev, S A; Alekseev, I B; Mel'nikova, N V; Alyab'ev, M V; Mal'tsev, D S

    2015-01-01

    to determine the frequency and severity of dry eye syndrome (DES) in primary open-angle glaucoma (POAG) patients that are newly diagnosed or already receiving beta blocker instillation therapy. A total of 127 patients (190 eyes) with POAG were divided into two groups. Group 1 included 55 newly diagnosed patients (88 eyes), group 2-72 POAG patients (102 eyes) instilling timolol 0.5% twice daily into the affected eye. The control group included 20 patients (40 eyes) aged 60-88 years (73.6 ± 9.2 years on average) with early age-related cataract. DES was found in 69 POAG patients (79%) who was just starting their topical hypotensive therapy and 85 of those (84%) under treatment (p = 0.39). One should take into account when prescribing ocular hypotensive therapy that newly diagnosed POAG patients usually already suffer from a dry eye. The use of topical beta blockers that contain preservatives exacerbates dry eye signs and symptoms in these patients.

  8. Open arthrolysis for elbow stiffness increases carrying angle but has no impact on functional recovery.

    PubMed

    Fan, Dapeng; Wang, Wei; Hildebrand, Kevin A; Fan, Cun-Yi

    2016-09-09

    With the exception of normal anatomic changes in the medial collateral ligament and radial head, other factors related to carrying angle changes have not been systematically studied. We reviewed patients who underwent open arthrolysis of the elbow, and evaluated if open arthrolysis could change carrying angle. We then identified factors associated with carrying angle changes. Fifty patients with a minimum of 24 months of follow-up after open arthrolysis were evaluated retrospectively. Preoperative and postoperative carrying angles were compared. The carrying angles of 36 elbows in 36 patients were unchanged after surgery (Group A), while the carrying angles of 14 elbows in 14 patients increased postoperatively (Group B). In Group A, mean postoperative extension and flexion were 7° (range 0-24°) and 125° (range 10-135°) respectively, while mean postoperative pronation and supination were 60° (range 50-80°) and 65° (range 30-85°), respectively. In Group B, mean postoperative extension and flexion were 25° (range 0-40°) and 128° (range 60-138°), while mean postoperative pronation and supination were 65° (range 45-85°) and 60° (range 45-75°), respectively. No significant difference in range of motion and Mayo Elbow Performance Score was observed between the two groups. During open arthrolysis, humeral trochlea debridement and techniques for improving forearm rotation could increase carrying angle. However, this had no impact on elbow functional recovery.

  9. Anterior segment parameters as predictors of intraocular pressure reduction after phacoemulsification in eyes with open-angle glaucoma.

    PubMed

    Hsia, Yen C; Moghimi, Sasan; Coh, Paul; Chen, Rebecca; Masis, Marisse; Lin, Shan C

    2017-07-01

    To evaluate intraocular pressure (IOP) change after cataract surgery in eyes with open-angle glaucoma (OAG) and its relationship to angle and anterior segment parameters measured by anterior segment optical coherence tomography (AS-OCT). University of California, San Francisco, California, USA. Prospective case series. Eyes were placed into a narrow-angle group or open-angle group based on gonioscopy grading. Biometric parameters were measured using AS-OCT (Visante) preoperatively, and IOP 4 months after surgery was obtained. The IOP change and its relationship to AS-OCT parameters were evaluated. Eighty-one eyes of 69 patients were enrolled. The mean age of the patients was 76.8 years. The preoperative IOP was 15.02 mm Hg on 1.89 glaucoma medications. The average mean deviation of preoperative visual field was -4.58 dB. The mean IOP reduction was 2.1 mm Hg (12.8%) from a preoperative mean of 15.0 mm Hg. The IOP reduction was significantly greater in eyes with narrow angles than in eyes with open angles (20.4% versus 8.0%) (P = .002). In multivariate analysis, preoperative IOP (β = -0.53, P < .001, R 2  = 0.40), angle-opening distance at 500 mm (β = 5.83, P = .02, R 2  = 0.45), angle-opening distance at 750 mm (β = 5.82, P = .001, R 2  = 0.52), and lens vault (β = -0.002, P = .009, R 2  = 0.47) were associated with IOP reduction postoperatively. In eyes with OAG, IOP reduction after cataract surgery was greater in eyes with narrower angles. Preoperative IOP, angle-opening distance, and lens vault were predictors for IOP reduction. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Investigation of Blade Angle of an Open Cross-Flow Runner

    NASA Astrophysics Data System (ADS)

    Katayama, Yusuke; Iio, Shouichiro; Veerapun, Salisa; Uchiyama, Tomomi

    2015-04-01

    The aim of this study was to develop a nano-hydraulic turbine utilizing drop structure in irrigation channels or industrial waterways. This study was focused on an open-type cross-flow turbine without any attached equipment for cost reduction and easy maintenance. In this study, the authors used an artificial indoor waterfall as lab model. Test runner which is a simple structure of 20 circular arc-shaped blades sandwiched by two circular plates was used The optimum inlet blade angle and the relationship between the power performance and the flow rate approaching theoretically and experimentally were investigated. As a result, the optimum inlet blade angle due to the flow rate was changed. Additionally, allocation rate of power output in 1st stage and 2nd stage is changed by the blade inlet angle.

  11. Tank-Binding Kinase 1 (TBK1) Gene and Open-Angle Glaucomas (An American Ophthalmological Society Thesis)

    PubMed Central

    Fingert, John H.; Robin, Alan L.; Scheetz, Todd E.; Kwon, Young H.; Liebmann, Jeffrey M.; Ritch, Robert; Alward, Wallace L.M.

    2016-01-01

    Purpose To investigate the role of TANK-binding kinase 1 (TBK1) gene copy-number variations (ie, gene duplications and triplications) in the pathophysiology of various open-angle glaucomas. Methods In previous studies, we discovered that copy-number variations in the TBK1 gene are associated with normal-tension glaucoma. Here, we investigated the prevalence of copy-number variations in cohorts of patients with other open-angle glaucomas—juvenile-onset open-angle glaucoma (n=30), pigmentary glaucoma (n=209), exfoliation glaucoma (n=225), and steroid-induced glaucoma (n=79)—using a quantitative polymerase chain reaction assay. Results No TBK1 gene copy-number variations were detected in patients with juvenile-onset open-angle glaucoma, pigmentary glaucoma, or steroid-induced glaucoma. A TBK1 gene duplication was detected in one (0.44%) of the 225 exfoliation glaucoma patients. Conclusions TBK1 gene copy-number variations (gene duplications and triplications) have been previously associated with normal-tension glaucoma. An exploration of other open-angle glaucomas detected a TBK1 copy-number variation in a patient with exfoliation glaucoma, which is the first example of a TBK1 mutation in a glaucoma patient with a diagnosis other than normal-tension glaucoma. A broader phenotypic range may be associated with TBK1 copy-number variations, although mutations in this gene are most often detected in patients with normal-tension glaucoma. PMID:27881886

  12. Tank-Binding Kinase 1 (TBK1) Gene and Open-Angle Glaucomas (An American Ophthalmological Society Thesis).

    PubMed

    Fingert, John H; Robin, Alan L; Scheetz, Todd E; Kwon, Young H; Liebmann, Jeffrey M; Ritch, Robert; Alward, Wallace L M

    2016-08-01

    To investigate the role of TANK-binding kinase 1 ( TBK1 ) gene copy-number variations (ie, gene duplications and triplications) in the pathophysiology of various open-angle glaucomas. In previous studies, we discovered that copy-number variations in the TBK1 gene are associated with normal-tension glaucoma. Here, we investigated the prevalence of copy-number variations in cohorts of patients with other open-angle glaucomas-juvenile-onset open-angle glaucoma (n=30), pigmentary glaucoma (n=209), exfoliation glaucoma (n=225), and steroid-induced glaucoma (n=79)-using a quantitative polymerase chain reaction assay. No TBK1 gene copy-number variations were detected in patients with juvenile-onset open-angle glaucoma, pigmentary glaucoma, or steroid-induced glaucoma. A TBK1 gene duplication was detected in one (0.44%) of the 225 exfoliation glaucoma patients. TBK1 gene copy-number variations (gene duplications and triplications) have been previously associated with normal-tension glaucoma. An exploration of other open-angle glaucomas detected a TBK1 copy-number variation in a patient with exfoliation glaucoma, which is the first example of a TBK1 mutation in a glaucoma patient with a diagnosis other than normal-tension glaucoma. A broader phenotypic range may be associated with TBK1 copy-number variations, although mutations in this gene are most often detected in patients with normal-tension glaucoma.

  13. Trabecular Meshwork Height in Primary Open-Angle Glaucoma Versus Primary Angle-Closure Glaucoma.

    PubMed

    Masis, Marisse; Chen, Rebecca; Porco, Travis; Lin, Shan C

    2017-11-01

    To determine if trabecular meshwork (TM) height differs between primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG) eyes. Prospective, cross-sectional clinical study. Adult patients were consecutively recruited from glaucoma clinics at the University of California, San Francisco, from January 2012 to July 2015. Images were obtained from spectral-domain optical coherence tomography (Cirrus OCT; Carl Zeiss Meditec, Inc, Dublin, California, USA). Univariate and multivariate linear mixed models comparing TM height and glaucoma type were performed to assess the relationship between TM height and glaucoma subtype. Mixed-effects regression was used to adjust for the use of both eyes in some subjects. The study included 260 eyes from 161 subjects, composed of 61 men and 100 women. Mean age was 70 years (SD 11.77). There were 199 eyes (123 patients) in the POAG group and 61 eyes (38 patients) in the PACG group. Mean TM heights in the POAG and PACG groups were 812 ± 13 μm and 732 ± 27 μm, respectively, and the difference was significant in univariate analysis (P = .004) and in multivariate analysis (β = -88.7 [24.05-153.5]; P = .008). In this clinic-based population, trabecular meshwork height is shorter in PACG patients compared to POAG patients. This finding may provide insight into the pathophysiology of angle closure and provide assistance in future diagnosis, prevention, and management of the angle-closure spectrum of disorders. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Ocular surface disease incidence in patients with open-angle glaucoma.

    PubMed

    Radenković, Marija; Stanković-Babić, Gordana; Jovanović, Predrag; Djordjević-Jocić, Jasmina; Trenkić-Božinović, Marija

    2016-01-01

    Ocular surface disease (OSD) is a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbances, tear film instability with potential damage to the ocular surface, accompanied by increased tear film osmolarity and inflammation of the ocular surface. It is a consequence of disrupted homeostasis of lacrimal functional unit. The main pathogenetic mechanism stems from tear hyperosmolarity and tear film instability. The etiological classification is hyposecretory (Sy-Sjögren and non-Sjögren) and evaporative (extrinsic and intrinsic) form. Delphi panel classification grades disease stages. Antiglaucoma topical therapy causes exacerbation or occurrence of symptoms of dry eye due to main ingredients or preservatives (benzalkonium chloride – BAK), which are dose- and time-dependent. BAK reduces the stability of the lipid layer of tears, the number of goblet cells, induces apoptosis and inflammatory infiltration. The aim of this study was the analysis of the OSD incidence in open-angle glaucoma patients caused by topical medicamentous therapy. Retrospective analysis of examined patients with open-angle glaucoma was used. Increased incidence of moderate and advanced OSD Index degrees in the group of primary open-angle glaucoma (POAG) and pseudoexfoliative glaucoma. According to the Delphi Panel Scale the most common grade is IIb (POAG and pseudoexfoliative glaucoma). Evaporative form of OSD prevailed in all treatment groups. High percentage of dry eye in patients with higher concentrations of preservatives applied was noticed. OSD should be timely diagnosed and treated. Dry eye has an impact on surgical outcome and postoperative visual acuity, and in order to improve patient compliance and quality of life, symptoms of dry eye should be addressed and medications with lower concentrations of preservatives should be applied.

  15. iStent trabecular micro-bypass stent for open-angle glaucoma

    PubMed Central

    Le, Kim; Saheb, Hady

    2014-01-01

    Trabecular micro-bypass stents, commonly known as iStents, are micro-invasive glaucoma surgery (MIGS) devices used to treat open-angle glaucoma. Like other MIGS procedures that enhance trabecular outflow, the iStent lowers intraocular pressure (IOP) by creating a direct channel between the anterior chamber and Schlemm’s canal. iStents are typically implanted at the time of phacoemulsification for patients with open-angle glaucoma and visually significant cataracts. This review summarizes the published data regarding the efficacy, safety, and cost considerations of trabecular micro-bypass stents. Most studies found statistically significant reductions in mean IOP and ocular medication use after combined phacoemulsification with single or double iStent implantation. The devices were found to be very safe, with a safety profile similar to that of cataract surgery. Complications were infrequent, with the most common complications being temporary stent obstruction or malposition, which resolved with observation or secondary procedures. Future studies are needed to evaluate long-term outcomes, patient satisfaction, cost effectiveness, and expanded indications. PMID:25284980

  16. Predictors of Intraocular Pressure After Phacoemulsification in Primary Open-Angle Glaucoma Eyes with Wide Versus Narrower Angles (An American Ophthalmological Society Thesis)

    PubMed Central

    Lin, Shan C.; Masis, Marisse; Porco, Travis C.; Pasquale, Louis R.

    2017-01-01

    Purpose To assess if narrower-angle status and anterior segment optical coherence tomography (AS-OCT) parameters can predict intraocular pressure (IOP) drop in primary open-angle glaucoma (POAG) patients after cataract surgery. Methods This was a prospective case series of consecutive cataract surgery patients with POAG and no peripheral anterior synechiae (PAS) using a standardized postoperative management protocol. Preoperatively, patients underwent gonioscopy and AS-OCT. The same glaucoma medication regimen was resumed by 1 month. Potential predictors of IOP reduction included narrower-angle status by gonioscopy and angle-opening distance (AOD500) as well as other AS-OCT parameters. Mixed-effects regression adjusted for use of both eyes and other potential confounders. Results We enrolled 66 eyes of 40 glaucoma patients. The IOP reduction at 1 year was 4.2±3 mm Hg (26%, P<.001) in the narrower-angle group vs 2.2±3 mm Hg (14%, P<.001) in the wide-angle group (P=.027 for difference), as classified by gonioscopy. By AOD500 classification, the narrower-angle group had 3.4±3 mm Hg (21%, P<.001) reduction vs 2.5±3 mm Hg (16%, P<.001) in the wide-angle group (P=.031 for difference). When the entire cohort was assessed, iris thickness, iris area, and lens vault were correlated with increasing IOP reduction at 1 year (P<.05 for all). Conclusions In POAG eyes, cataract surgery lowered IOP to a greater degree in the narrower-angle group than in the wide-angle group, and parameters relating to iris thickness and area, as well as lens vault, were correlated with IOP reduction. These findings can guide ophthalmologists in their selection of cataract surgery as a potential management option. PMID:29147104

  17. Predictors of Intraocular Pressure After Phacoemulsification in Primary Open-Angle Glaucoma Eyes with Wide Versus Narrower Angles (An American Ophthalmological Society Thesis).

    PubMed

    Lin, Shan C; Masis, Marisse; Porco, Travis C; Pasquale, Louis R

    2017-08-01

    To assess if narrower-angle status and anterior segment optical coherence tomography (AS-OCT) parameters can predict intraocular pressure (IOP) drop in primary open-angle glaucoma (POAG) patients after cataract surgery. This was a prospective case series of consecutive cataract surgery patients with POAG and no peripheral anterior synechiae (PAS) using a standardized postoperative management protocol. Preoperatively, patients underwent gonioscopy and AS-OCT. The same glaucoma medication regimen was resumed by 1 month. Potential predictors of IOP reduction included narrower-angle status by gonioscopy and angle-opening distance (AOD500) as well as other AS-OCT parameters. Mixed-effects regression adjusted for use of both eyes and other potential confounders. We enrolled 66 eyes of 40 glaucoma patients. The IOP reduction at 1 year was 4.2±3 mm Hg (26%, P <.001) in the narrower-angle group vs 2.2±3 mm Hg (14%, P <.001) in the wide-angle group ( P =.027 for difference), as classified by gonioscopy. By AOD500 classification, the narrower-angle group had 3.4±3 mm Hg (21%, P <.001) reduction vs 2.5±3 mm Hg (16%, P <.001) in the wide-angle group ( P =.031 for difference). When the entire cohort was assessed, iris thickness, iris area, and lens vault were correlated with increasing IOP reduction at 1 year ( P <.05 for all). In POAG eyes, cataract surgery lowered IOP to a greater degree in the narrower-angle group than in the wide-angle group, and parameters relating to iris thickness and area, as well as lens vault, were correlated with IOP reduction. These findings can guide ophthalmologists in their selection of cataract surgery as a potential management option.

  18. Lack of Association of Mutations in Optineurin With Disease in Patients With Adult-onset Primary Open-angle Glaucoma

    PubMed Central

    Wiggs, Janey L.; Auguste, Josette; Allingham, R. Rand; Flor, Jason D.; Pericak-Vance, Margaret A.; Rogers, Kathryn; LaRocque, Karen R.; Graham, Felicia L.; Broomer, Bob; Del Bono, Elizabeth; Haines, Jonathan L.; Hauser, Michael

    2005-01-01

    Objective: To determine whether mutations in the optineurin gene contribute to susceptibility to adult-onset primary open-angle glaucoma. Methods: The optineurin gene was screened in 86 probands with adult-onset primary open-angle glaucoma and in 80 age-matched control subjects. Exons 4 and 5, containing the recurrent mutations identified in patients with normal-tension glaucoma, were sequenced in all individuals studied, while the remaining exons were screened for DNA sequence variants with denaturing high-performance liquid chromatography. Results: The recurrent mutation, Met98Lys, previously found to be associated with an increased risk of disease was found in 8 (9%) of 86 probands. We also found the Met98Lys mutation in 10% of individuals from a control population of similar age, sex, and ethnicity. Consistent segregation of the mutation with the disease was not demonstrated in any of the 8 families. No other DNA changes altering the amino acid structure of the protein were found. Conclusion: The mutations in the optineurin gene associated with normal-tension glaucoma are not associated with adult-onset primary open-angle glaucoma in this patient population. Clinical Relevance: Genetic abnormalities that render the optic nerve susceptible to degeneration are excellent candidates for genetic factors that could contribute to adult-onset primary open-angle glaucoma. Mutations in optineurin have been associated with normal-tension glaucoma, but are not associated with disease in patients with adult-onset primary open-angle glaucoma. This result may indicate that normal-tension glaucoma is not necessarily part of the phenotypic spectrum of adult open-angle glaucoma. PMID:12912697

  19. Early career researchers want Open Science.

    PubMed

    Farnham, Andrea; Kurz, Christoph; Öztürk, Mehmet Ali; Solbiati, Monica; Myllyntaus, Oona; Meekes, Jordy; Pham, Tra My; Paz, Clara; Langiewicz, Magda; Andrews, Sophie; Kanninen, Liisa; Agbemabiese, Chantal; Guler, Arzu Tugce; Durieux, Jeffrey; Jasim, Sarah; Viessmann, Olivia; Frattini, Stefano; Yembergenova, Danagul; Benito, Carla Marin; Porte, Marion; Grangeray-Vilmint, Anaïs; Curiel, Rafael Prieto; Rehncrona, Carin; Malas, Tareq; Esposito, Flavia; Hettne, Kristina

    2017-11-15

    Open Science is encouraged by the European Union and many other political and scientific institutions. However, scientific practice is proving slow to change. We propose, as early career researchers, that it is our task to change scientific research into open scientific research and commit to Open Science principles.

  20. Are we ready for genetic testing for primary open-angle glaucoma?

    PubMed

    Khawaja, Anthony P; Viswanathan, Ananth C

    2018-05-01

    Following a dramatic reduction in the cost of genotyping technology in recent years, there have been significant advances in the understanding of the genetic basis of glaucoma. Glaucoma patients represent around a quarter of all outpatient activity in the UK hospital eye service and are a huge burden for the National Health Service. A potential benefit of genetic testing is personalised glaucoma management, allowing direction of our limited healthcare resources to the glaucoma patients who most need it. Our review aims to summarise recent discoveries in the field of glaucoma genetics and to discuss their potential clinical utility. While genome-wide association studies have now identified over ten genes associated with primary open-angle glaucoma (POAG), individually, variants in these genes are not predictive of POAG in populations. There are data suggesting some of these POAG variants are associated with conversion from ocular hypertension to POAG and visual field progression among POAG patients. However, these studies have not been replicated yet and such genetic testing is not currently justified in clinical care. In contrast, genetic testing for inherited early-onset disease in relatives of POAG patients with a known genetic mutation is of clear benefit; this can support either regular review to commence early treatment when the disease develops, or discharge from ophthalmology services of relatives who do not carry the mutation. Genetic testing for POAG at a population level is not currently justified.

  1. Edge contact angle and modified Kelvin equation for condensation in open pores.

    PubMed

    Malijevský, Alexandr; Parry, Andrew O; Pospíšil, Martin

    2017-08-01

    We consider capillary condensation transitions occurring in open slits of width L and finite height H immersed in a reservoir of vapor. In this case the pressure at which condensation occurs is closer to saturation compared to that occurring in an infinite slit (H=∞) due to the presence of two menisci that are pinned near the open ends. Using macroscopic arguments, we derive a modified Kelvin equation for the pressure p_{cc}(L;H) at which condensation occurs and show that the two menisci are characterized by an edge contact angle θ_{e} that is always larger than the equilibrium contact angle θ, only equal to it in the limit of macroscopic H. For walls that are completely wet (θ=0) the edge contact angle depends only on the aspect ratio of the capillary and is well described by θ_{e}≈sqrt[πL/2H] for large H. Similar results apply for condensation in cylindrical pores of finite length. We test these predictions against numerical results obtained using a microscopic density-functional model where the presence of an edge contact angle characterizing the shape of the menisci is clearly visible from the density profiles. Below the wetting temperature T_{w} we find very good agreement for slit pores of widths of just a few tens of molecular diameters, while above T_{w} the modified Kelvin equation only becomes accurate for much larger systems.

  2. Retinal adaptation abnormalities in primary open-angle glaucoma.

    PubMed

    Dul, Mitchell; Ennis, Robert; Radner, Shira; Lee, Barry; Zaidi, Qasim

    2015-01-22

    Dynamic color and brightness adaptation are crucial for visual functioning. The effects of glaucoma on retinal ganglion cells (RGCs) could compromise these functions. We have previously used slow dynamic changes of light at moderate intensities to measure the speed and magnitude of subtractive adaptation in RGCs. We used the same procedure to test if RGC abnormalities cause slower and weaker adaptation for patients with glaucoma when compared to age-similar controls. We assessed adaptation deficits in specific classes of RGCs by testing along the three cardinal color axes that isolate konio, parvo, and magno RGCs. For one eye each of 10 primary open-angle glaucoma patients and their age-similar controls, we measured the speed and magnitude of adapting to 1/32 Hz color modulations along the three cardinal axes, at central fixation and 8° superior, inferior, nasal, and temporal to fixation. In all 15 comparisons (5 locations × 3 color axes), average adaptation was slower and weaker for glaucoma patients than for controls. Adaptation developed slower at central targets than at 8° eccentricities for controls, but not for patients. Adaptation speed and magnitude differed between affected and control eyes even at retinal locations showing no visual field loss with clinical perimetry. Neural adaptation is weaker in glaucoma patients for all three classes of RGCs. Since adaptation abnormalities are manifested even at retinal locations not exhibiting a visual field loss, this novel form of assessment may offer a functional insight into glaucoma and an early diagnosis tool. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  3. Retinal Adaptation Abnormalities in Primary Open-Angle Glaucoma

    PubMed Central

    Dul, Mitchell; Ennis, Robert; Radner, Shira; Lee, Barry; Zaidi, Qasim

    2015-01-01

    Purpose. Dynamic color and brightness adaptation are crucial for visual functioning. The effects of glaucoma on retinal ganglion cells (RGCs) could compromise these functions. We have previously used slow dynamic changes of light at moderate intensities to measure the speed and magnitude of subtractive adaptation in RGCs. We used the same procedure to test if RGC abnormalities cause slower and weaker adaptation for patients with glaucoma when compared to age-similar controls. We assessed adaptation deficits in specific classes of RGCs by testing along the three cardinal color axes that isolate konio, parvo, and magno RGCs. Methods. For one eye each of 10 primary open-angle glaucoma patients and their age-similar controls, we measured the speed and magnitude of adapting to 1/32 Hz color modulations along the three cardinal axes, at central fixation and 8° superior, inferior, nasal, and temporal to fixation. Results. In all 15 comparisons (5 locations × 3 color axes), average adaptation was slower and weaker for glaucoma patients than for controls. Adaptation developed slower at central targets than at 8° eccentricities for controls, but not for patients. Adaptation speed and magnitude differed between affected and control eyes even at retinal locations showing no visual field loss with clinical perimetry. Conclusions. Neural adaptation is weaker in glaucoma patients for all three classes of RGCs. Since adaptation abnormalities are manifested even at retinal locations not exhibiting a visual field loss, this novel form of assessment may offer a functional insight into glaucoma and an early diagnosis tool. PMID:25613950

  4. Oxidative stress markers in patients with primary open-angle glaucoma.

    PubMed

    Ghanem, Asaad A; Arafa, Lamiaa F; El-Baz, Ayman

    2010-04-01

    To investigate the levels of antioxidant enzymes catalase (CAT), glutathione peroxidase (GPO), superoxide dismutase (SOD), and malondialdehyde (MDA) in human eyes with primary open-angle glaucoma (POAG) and to correlate their concentrations with severity of glaucoma. A prospective cases control study. Thirty patients with primary open-angle glaucoma and twenty-five patients with senile cataracts of matched age and gender were included in the study prospectively. Aqueous humor samples were obtained by paracentesis at the time of elective surgery for glaucomatous and cataractous patients. Aqueous humor were analyzed for CAT, GPO, SOD, and MDA status. GPO, SOD, and MDA enzyme levels revealed a high significant increase in aqueous humor of POAG patients with respect to the comparative group of cataract patients (P < 0.001). No significant difference in the activity of CAT enzyme in aqueous humor of POAG and cataract patient (P = 0.201). Significant correlation was found between the MDA enzyme level and severe visual field loss (P < 0.001) in POAG patients. Increased levels of aqueous humor GPO, SOD, and MDA may be associated with POAG. In addition, they may be useful antioxidant enzyme levels in aqueous humor of POAG patients as a result of glaucoma disease and not a cause.

  5. Blindness following bleb-related infection in open angle glaucoma.

    PubMed

    Yamada, Hiroki; Sawada, Akira; Kuwayama, Yasuaki; Yamamoto, Tetsuya

    2014-11-01

    To estimate the risk of blindness following bleb-related infection after trabeculectomy with mitomycin C in open angle glaucoma, utilizing data obtained from two prospective multicenter studies. The incidence of bleb-related infection in open angle glaucoma after the first or second glaucoma surgery was calculated using a Kaplan-Meier analysis and data from the Collaborative Bleb-related Infection Incidence and Treatment Study (CBIITS). The rate of blindness following bleb-related infection was calculated using data from the Japan Glaucoma Society Survey of Bleb-related Infection (JGSSBI). Finally, the rate of blindness following bleb-related infection after filtering surgery was estimated based on the above two data sets. Blindness was defined as an eye with a visual acuity of 0.04 or less. The incidences of development of bleb-related infection at 5 years were 2.6 ± 0.7 % (calculated cumulative incidence ± standard error) for all infections and 0.9 ± 0.4 % for endophthalmitis in all cases in the CBIITS data. The rates of blindness in the JGSSBI data were 14 % for the total cases with bleb-related infection and 30 % for the endophthalmitis subgroup. The rate of blindness developing within 5 years following trabeculectomy was estimated to be approximately 0.24-0.36 %. The rate of blindness following bleb-related infection within 5 years after trabeculectomy is considerable and thus careful consideration must be given to the indication for trabeculectomy and the selection of surgical techniques.

  6. Angle closure glaucoma in congenital ectropion uvea.

    PubMed

    Wang, Grace M; Thuente, Daniel; Bohnsack, Brenda L

    2018-06-01

    Congenital ectropion uvea is a rare anomaly, which is associated with open, but dysplastic iridocorneal angles that cause childhood glaucoma. Herein, we present 3 cases of angle-closure glaucoma in children with congenital ectropion uvea. Three children were initially diagnosed with unilateral glaucoma secondary to congenital ectropion uvea at 7, 8 and 13 years of age. The three cases showed 360° of ectropion uvea and iris stromal atrophy in the affected eye. In one case, we have photographic documentation of progression to complete angle closure, which necessitated placement of a glaucoma drainage device 3 years after combined trabeculotomy and trabeculectomy. The 2 other cases, which presented as complete angle closure, also underwent glaucoma drainage device implantation. All three cases had early glaucoma drainage device encapsulation (within 4 months) and required additional surgery (cycloablation or trabeculectomy). Congenital ectropion uvea can be associated with angle-closure glaucoma, and placement of glaucoma drainage devices in all 3 of our cases showed early failure due to plate encapsulation. Glaucoma in congenital ectropion uvea requires attention to angle configuration and often requires multiple surgeries to obtain intraocular pressure control.

  7. Large-angle cosmic microwave background anisotropies in an open universe

    NASA Technical Reports Server (NTRS)

    Kamionkowski, Marc; Spergel, David N.

    1994-01-01

    If the universe is open, scales larger than the curvature scale may be probed by observation of large-angle fluctuations in the cosmic microwave background (CMB). We consider primordial adiabatic perturbations and discuss power spectra that are power laws in volume, wavelength, and eigenvalue of the Laplace operator. Such spectra may have arisen if, for example, the universe underwent a period of `frustated' inflation. The resulting large-angle anisotropies of the CMB are computed. The amplitude generally increases as Omega is decreased but decreases as h is increased. Interestingly enough, for all three Ansaetze, anisotropies on angular scales larger than the curvature scale are suppressed relative to the anisotropies on scales smaller than the curvature scale, but cosmic variance makes discrimination between various models difficult. Models with 0.2 approximately less than Omega h approximately less than 0.3 appear compatible with CMB fluctuations detected by Cosmic Background Explorer Satellite (COBE) and the Tenerife experiment and with the amplitude and spectrum of fluctuations of galaxy counts in the APM, CfA, and 1.2 Jy IRAS surveys. COBE normalization for these models yields sigma(sub 8) approximately = 0.5 - 0.7. Models with smaller values of Omega h when normalized to COBE require bias factors in excess of 2 to be compatible with the observed galaxy counts on the 8/h Mpc scale. Requiring that the age of the universe exceed 10 Gyr implies that Omega approximately greater than 0.25, while requiring that from the last-scattering term in the Sachs-Wolfe formula, large-angle anisotropies come primarily from the decay of potential fluctuations at z approximately less than 1/Omega. Thus, if the universe is open, COBE has been detecting temperature fluctuations produced at moderate redshift rather than at z approximately 1300.

  8. Early Ectopic Recurrence of Craniopharyngioma in the Cerebellopontine Angle.

    PubMed

    Mahdi, Mohamad-Motaz Al; Krauss, Joachim K; Nakamura, Makoto; Brandis, Almuth; Hong, Bujung

    2018-01-01

    Ectopic recurrence of craniopharyngioma in the cerebellopontine angle after surgical resection of a suprasellar craniopharyngioma is rare. Thus, only 5 cases were reported with a delay ranging between 4 and 26 years after removal of the primary tumor. We report a unique case of ectopic recurrence of craniopharyngioma in the cerebellopontine angle, which occurred at only 4 months after surgical resection of the primary tumor. A 24-year-old man underwent resection of a suprasellar craniopharyngioma via a right pterional approach four months earlier. During follow-up, cerebral magnetic resonance imaging (MRI) showed a round homogeneous contrast-enhancing tumor in the right cerebellopontine angle with neither relation to the internal auditory canal nor to the dura mater. After microsurgical resection, histopathological findings revealed ectopic recurrence of craniopharyngioma with similar tumors like the primary tumor. Although infrequent, craniopharyngioma may disseminate via the cerebrospinal fluid during surgical resection and grow in an ectopic place. Early follow-up and MRI scan following resection of a craniopharyngioma is recommended.

  9. The Influence of Structure Heights and Opening Angles of Micro- and Nanocones on the Macroscopic Surface Wetting Properties

    NASA Astrophysics Data System (ADS)

    Schneider, Ling; Laustsen, Milan; Mandsberg, Nikolaj; Taboryski, Rafael

    2016-02-01

    We discuss the influence of surface structure, namely the height and opening angles of nano- and microcones on the surface wettability. We show experimental evidence that the opening angle of the cones is the critical parameter on sample superhydrophobicity, namely static contact angles and roll-off angles. The textured surfaces are fabricated on silicon wafers by using a simple one-step method of reactive ion etching at different processing time and gas flow rates. By using hydrophobic coating or hydrophilic surface treatment, we are able to switch the surface wettability from superhydrophilic to superhydrophobic without altering surface structures. In addition, we show examples of polymer replicas (polypropylene and poly(methyl methacrylate) with different wettability, fabricated by injection moulding using templates of the silicon cone-structures.

  10. Refractory open-angle glaucoma after neodymium-yttrium-aluminum-garnet laser lysis of vitreous floaters.

    PubMed

    Cowan, Lisa A; Khine, Kay T; Chopra, Vikas; Fazio, Doreen T; Francis, Brian A

    2015-01-01

    To illustrate 3 cases of chronic open-angle glaucoma secondary to the neodymium-yttrium-aluminum-garnet (Nd:YAG) laser vitreolysis procedure for symptomatic vitreous floaters. Observational case series. Location of the study was the Doheny Eye Institute. Three eyes of 2 patients who developed chronic open-angle glaucoma after Nd:YAG vitreolysis for symptomatic floaters presenting with very high intraocular pressure (IOP >40 mm Hg) were selected. The time from the laser treatment to the onset of elevated pressure ranges from 1 week to 8 months. There was no associated inflammation, steroid use, or other identifiable cause of chronic IOP elevation. All eyes were treated initially with glaucoma medication, followed by selective laser trabeculoplasty (SLT) and eventually glaucoma surgery (Trabectome) in 2 eyes for disease management. In all eyes, intraocular pressures were eventually stabilized within a normal pressure range from 18 to 38 months following Nd:YAG vitreolysis. At the latest follow-up post surgery, all eyes had intraocular pressures of 22 mm Hg or less with or without medications. Secondary open-angle glaucoma is a complication of Nd:YAG vitreolysis for symptomatic floaters that may present with an increase in intraocular pressure immediately, or many months after the surgery. Furthermore this complication may be permanent and require chronic medical therapy or glaucoma surgery. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Comparison between visual field defect in pigmentary glaucoma and primary open-angle glaucoma.

    PubMed

    Nilforushan, Naveed; Yadgari, Maryam; Jazayeri, Anisalsadat

    2016-10-01

    To compare visual field defect patterns between pigmentary glaucoma and primary open-angle glaucoma. Retrospective, comparative study. Patients with diagnosis of primary open-angle glaucoma (POAG) and pigmentary glaucoma (PG) in mild to moderate stages were enrolled in this study. Each of the 52 point locations in total and pattern deviation plot (excluding 2 points adjacent to blind spot) of 24-2 Humphrey visual field as well as six predetermined sectors were compared using SPSS software version 20. Comparisons between 2 groups were performed with the Student t test for continuous variables and the Chi-square test for categorical variables. Thirty-eight eyes of 24 patients with a mean age of 66.26 ± 11 years (range 48-81 years) in the POAG group and 36 eyes of 22 patients with a mean age of 50.52 ± 11 years (range 36-69 years) in the PG group were studied. (P = 0.00). More deviation was detected in points 1, 3, 4, and 32 in total deviation (P = 0.03, P = 0.015, P = 0.018, P = 0.023) and in points 3, 4, and 32 in pattern deviation (P = 0.015, P = 0.049, P = 0.030) in the POAG group, which are the temporal parts of the field. It seems that the temporal area of the visual field in primary open-angle glaucoma is more susceptible to damage in comparison with pigmentary glaucoma.

  12. Macular Thickness Variability in Primary Open Angle Glaucoma Patients using Optical Coherence Tomography

    PubMed Central

    Agarwal, Prakashchand; Sathyan, P; Saini, VK

    2014-01-01

    ABSTRACT Aim: To compare the difference of retinal macular thickness and macular volume using optical coherence tomography (OCT) in primary open angle glaucoma (POAG) patients with the normal subjects. Materials and methods: This observational case control study included primary open angle glaucoma (POAG) patients (n = 124 eyes) and healthy subjects in the control group (n = 124 eyes). All subjects underwent detailed history, general and systemic exami -nation. Complete ocular examination included best corrected visual acuity (BCVA), slit lamp examination, intraocular pressure (IOP), central corneal thickness, gonioscopy, dilated fundus biomicroscopy. Field analysis was done by white on white Humphrey Field Analyzer (Carl Zeiss). Optical coherence tomography imaging of macular area was performed using Stratus OCT (OCT 3, Version 4, Carl Zeiss Inc, Dublin, California, USA). In both these groups, parameters analyzed were macular thickness, inner macular thicknesses (IMT), outer macular thicknesses (OMT), central macular thick ness (CMT) and total macular volume (TMV). Results: The POAG group had significantly decreased values of TMV, OMT and IMT, compared to control group, while there was no difference in CMT, presumably due to absence of ganglion cells in the central part. Thus, macular thickness and volume parameters may be used for making the diagnosis of glaucoma especially in patients with abnormalities of disc. Conclusion: Macular thickness parameters correlated well with the diagnosis of glaucoma. How to cite this article: Sharma A, Agarwal P, Sathyan P, Saini VK. Macular Thickness Variability in Primary Open Angle Glaucoma Patients using Optical Coherence Tomography. J Current Glau Prac 2014;8(1):10-14. PMID:26997801

  13. Progression of visual field in patients with primary open-angle glaucoma - ProgF study 1.

    PubMed

    Aptel, Florent; Aryal-Charles, Nishal; Giraud, Jean-Marie; El Chehab, Hussam; Delbarre, Maxime; Chiquet, Christophe; Romanet, Jean-Paul; Renard, Jean-Paul

    2015-12-01

    To evaluate the visual field rate of progression of patients with treated ocular hypertension (OHT) and primary open-angle glaucoma (POAG) in clinical practice, using the mean deviation (MD) and the visual field index (VFI). Non-interventional cohort study. From a large multicentre database representative of the French population, 441 eyes of 228 patients with treated OHT or POAG followed up at least 6 years with Humphrey 24.2 Sita-Standard visual field examination at least twice a year were identified. From initial data, eyes were classified in five groups: 121 with OHT, 188 with early glaucoma (MD greater than -6 dB), 45 with moderate glaucoma (MD -6 to -12 dB), 41 with advanced glaucoma (MD -12 to -18 dB) and 46 with severe glaucoma (MD less than -18 dB). Rate of progression during the follow-up period was calculated using the trend analysis of the Guided Progression Analysis software. The mean duration of follow-up was 8.4 ± 2.7 years and the mean number of visual field, 18.4 ± 3.5. In eyes with OHT, rate of progression was -0.09 dB/year (-0.17%VFI/year). In eyes with POAG, rate of progression was -0.32 dB/year (-0.83%VFI/year) in eyes with early glaucoma, -0.52 dB/year (-1.81%VFI/year) in moderate glaucoma, -0.54 dB/year (-2.35%VFI/year) in advanced glaucoma and -0.45 dB/year (-1.97%VFI/year) in severe glaucoma. In eyes with POAG, a significant progression (p < 0.05) was detected in 159 of 320 eyes (49.7%) with trend analysis and 117 of 320 eyes (36.6%, likely progression) or 183 of 320 eyes (57.2%, possible and likely progression) with event analysis. Primary open-angle glaucoma is a progressive disease in the majority of patients despite cautioned treatment and follow-up. The rate of progression varies greatly among subjects. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  14. [Magnetotherapy designed to affect cervical sympathetic ganglia for the treatment of patients with primary open-angle glaucoma].

    PubMed

    Veselova, E V; Kamenskikh, T G; Raĭgorodkiĭ, Iu M; Kolbenev, I O; Myshkina, E S

    2010-01-01

    The traveling magnetic field was used to treat primary open-angle glaucoma. The field was applied to the projection of cervical sympathetic ganglia of the patients. Hemodynamic parameters of posterior short ciliary arteries and central retinal artery were analysed along with visual evoked potentials, visual field limits, and visual acuity. It was shown that magnetotherapy with the use of an AMO-ATOS apparatus produces better clinical results in patients with stage I and II primary open-angle glaucoma compared with medicamentous therapy (intake of trental tablets).

  15. Long Term Results of Visual Field Progression Analysis in Open Angle Glaucoma Patients Under Treatment.

    PubMed

    Kocatürk, Tolga; Bekmez, Sinan; Katrancı, Merve; Çakmak, Harun; Dayanır, Volkan

    2015-01-01

    To evaluate visual field progression with trend and event analysis in open angle glaucoma patients under treatment. Fifteen year follow-up results of 408 eyes of 217 glaucoma patients who were followed at Adnan Menderes University, Department of Ophthalmology between 1998 and 2013 were analyzed retrospectively. Visual field data were collected for Mean Deviation (MD), Visual Field Index (VFI), and event occurrence. There were 146 primary open-angle glaucoma (POAG), 123 pseudoexfoliative glaucoma (XFG) and 139 normal tension glaucoma (NTG) eyes. MD showed significant change in all diagnostic groups (p<0.001). The difference of VFI between first and last examinations were significantly different in POAG (p<0.001), and XFG (p<0.003) but not in NTG. VFI progression rates were -0.3, -0.43, and -0.2 % loss/year in treated POAG, XFG, and NTG, respectively. The number of empty triangles were statistically different between POAG-NTG (p=0.001), and XFG-NTG (p=0.002) groups. The number of half-filled (p=0.002), and full-filled (p=0.010) triangles were significantly different between XFG-NTG groups. Functional long-term follow-up of glaucoma patients can be monitored with visual field indices. We herein report our fifteen year follow-up results in open angle glaucoma.

  16. Vascular tone pathway polymorphisms in relation to primary open-angle glaucoma.

    PubMed

    Kang, J H; Loomis, S J; Yaspan, B L; Bailey, J C; Weinreb, R N; Lee, R K; Lichter, P R; Budenz, D L; Liu, Y; Realini, T; Gaasterland, D; Gaasterland, T; Friedman, D S; McCarty, C A; Moroi, S E; Olson, L; Schuman, J S; Singh, K; Vollrath, D; Wollstein, G; Zack, D J; Brilliant, M; Sit, A J; Christen, W G; Fingert, J; Forman, J P; Buys, E S; Kraft, P; Zhang, K; Allingham, R R; Pericak-Vance, M A; Richards, J E; Hauser, M A; Haines, J L; Wiggs, J L; Pasquale, L R

    2014-06-01

    Vascular perfusion may be impaired in primary open-angle glaucoma (POAG); thus, we evaluated a panel of markers in vascular tone-regulating genes in relation to POAG. We used Illumina 660W-Quad array genotype data and pooled P-values from 3108 POAG cases and 3430 controls from the combined National Eye Institute Glaucoma Human Genetics Collaboration consortium and Glaucoma Genes and Environment studies. Using information from previous literature and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathways, we compiled single-nucleotide polymorphisms (SNPs) in 186 vascular tone-regulating genes. We used the 'Pathway Analysis by Randomization Incorporating Structure' analysis software, which performed 1000 permutations to compare the overall pathway and selected genes with comparable randomly generated pathways and genes in their association with POAG. The vascular tone pathway was not associated with POAG overall or POAG subtypes, defined by the type of visual field loss (early paracentral loss (n=224 cases) or only peripheral loss (n=993 cases)) (permuted P≥0.20). In gene-based analyses, eight were associated with POAG overall at permuted P<0.001: PRKAA1, CAV1, ITPR3, EDNRB, GNB2, DNM2, HFE, and MYL9. Notably, six of these eight (the first six listed) code for factors involved in the endothelial nitric oxide synthase activity, and three of these six (CAV1, ITPR3, and EDNRB) were also associated with early paracentral loss at P<0.001, whereas none of the six genes reached P<0.001 for peripheral loss only. Although the assembled vascular tone SNP set was not associated with POAG, genes that code for local factors involved in setting vascular tone were associated with POAG.

  17. Evaluation of blotchy pigments in the anterior chamber angle as a sign of angle closure

    PubMed Central

    Rao, Harsha L; Mungale, Sachin C; Kumbar, Tukaram; Parikh, Rajul S; Garudadri, Chandra S

    2012-01-01

    Background: Blotchy pigments in the anterior chamber (AC) angle are considered diagnostic of primary angle closure (PAC). But there are no reports either on the prevalence of blotchy pigments in AC angles or the validity of this sign. Aims: To determine the prevalence of blotchy pigments in AC angles and to evaluate their relationship with glaucomatous optic neuropathy (GON) in eyes with occludable angles. Setting and Design: Cross-sectional, comparative study. Materials and Methods: Gonioscopy was performed in 1001 eyes of 526 subjects (245 eyes of 148 consecutive, occludable angle subjects and 756 eyes of 378 non-consecutive, open angle subjects), above 35 years of age. Quadrant-wise location of blotchy pigments was documented. Statistical Analysis: Odds of blotchy pigments in occludable angles against that in open angles were evaluated. Relationship of GON with blotchy pigments in occludable angle eyes was evaluated using a multivariate model. Results: Prevalence of blotchy pigments in occludable angles was 28.6% (95% CI, 22.9-34.3) and in open angles was 4.7% (95% CI, 3.2-6.3). Blotchy pigments were more frequently seen in inferior (16%) and superior quadrants (15%) of occludable angles, and inferior quadrant of open angles (4%). Odds of superior quadrant blotchy pigments in occludable angles were 33 times that in open angles. GON was seen in 107 occludable angle eyes. Blotchy pigments were not significantly associated with GON (odds ratio = 0.5; P = 0.1). Conclusions: Blotchy pigments were seen in 28.6% of occludable angle eyes and 4.7% of open angles eyes. Presence of blotchy pigments in the superior quadrant is more common in occludable angles. Presence of GON in occludable angle eyes was not associated with blotchy pigments. PMID:23202393

  18. Pathophysiology of primary open-angle glaucoma from a neuroinflammatory and neurotoxicity perspective: a review of the literature.

    PubMed

    Evangelho, Karine; Mogilevskaya, Maria; Losada-Barragan, Monica; Vargas-Sanchez, Jeinny Karina

    2017-12-30

    Glaucoma is the leading cause of blindness in humans, affecting 2% of the population. This disorder can be classified into various types including primary, secondary, glaucoma with angle closure and with open angle. The prevalence of distinct types of glaucoma differs for each particular region of the world. One of the most common types of this disease is primary open-angle glaucoma (POAG), which is a complex inherited disorder characterized by progressive retinal ganglion cell death, optic nerve head excavation and visual field loss. Nowadays, POAG is considered an optic neuropathy, while intraocular pressure is proposed to play a fundamental role in its pathophysiology and especially in optic disk damage. However, the exact mechanism of optic nerve head damage remains a topic of debate. This literature review aims to bring together the information on the pathophysiology of primary open-angle glaucoma, particularly focusing on neuroinflammatory mechanisms leading to the death of the retinal ganglion cell. A literature search was done on PubMed using key words including primary open-angle glaucoma, retinal ganglion cells, Müller cells, glutamate, glial cells, ischemia, hypoxia, exitotoxicity, neuroinflammation, axotomy and neurotrophic factors. The literature was reviewed to collect the information published about the pathophysiologic mechanisms of RGC death in the POAG, from a neuroinflammatory and neurotoxicity perspective. Proposed mechanisms for glaucomatous damage are a result of pressure in RGC followed by ischemia, hypoxia of the ONH, and consequently death due to glutamate-induced excitotoxicity, deprivation of energy and oxygen, increase in levels of inflammatory mediators and alteration of trophic factors flow. These events lead to blockage of anterograde and retrograde axonal transport with ensuing axotomy and eventually blindness. The damage to ganglion cells and eventually glaucomatous injury can occur via various mechanisms including baric trauma

  19. The Use of Sun Elevation Angle for Stereogrammetric Boreal Forest Height in Open Canopies

    NASA Technical Reports Server (NTRS)

    Montesano, Paul M.; Neigh, Christopher; Sun, Guoqing; Duncanson, Laura Innice; Van Den Hoek, Jamon; Ranson, Kenneth Jon

    2017-01-01

    Stereogrammetry applied to globally available high resolution spaceborne imagery (HRSI; less than 5 m spatial resolution) yields fine-scaled digital surface models (DSMs) of elevation. These DSMs may represent elevations that range from the ground to the vegetation canopy surface, are produced from stereoscopic image pairs (stereo pairs) that have a variety of acquisition characteristics, and have been coupled with lidar data of forest structure and ground surface elevation to examine forest height. This work explores surface elevations from HRSI DSMs derived from two types of acquisitions in open canopy forests. We (1) apply an automated mass-production stereogrammetry workflow to along-track HRSI stereo pairs, (2) identify multiple spatially coincident DSMs whose stereo pairs were acquired under different solar geometry, (3) vertically co-register these DSMs using coincident spaceborne lidar footprints (from ICESat-GLAS) as reference, and(4) examine differences in surface elevations between the reference lidar and the co-registered HRSI DSMs associated with two general types of acquisitions (DSM types) from different sun elevation angles. We find that these DSM types, distinguished by sun elevation angle at the time of stereo pair acquisition, are associated with different surface elevations estimated from automated stereogrammetry in open canopy forests. For DSM values with corresponding reference ground surface elevation from spaceborne lidar footprints in open canopy northern Siberian Larix forests with slopes less than10, our results show that HRSI DSM acquired with sun elevation angles greater than 35deg and less than 25deg (during snow-free conditions) produced characteristic and consistently distinct distributions of elevation differences from reference lidar. The former include DSMs of near-ground surfaces with root mean square errors less than 0.68 m relative to lidar. The latter, particularly those with angles less than 10deg, show distributions with

  20. Brightness discrimination test is not useful in screening for open angle glaucoma.

    PubMed

    Peter, E; Thomas, R; Muliyil, J

    1996-06-01

    Brightness discrimination test (BDT) is routinely employed to assess asymmetrical optic nerve dysfunction and has been suggested as a screening test for primary open angle glaucoma (POAG). We tested the reliability and validity of BDT in the diagnosis of POAG. The study groups included 34 patients with established primary open angle glaucoma, 20 glaucoma suspects, and 33 age-sex matched controls. Cataract was not an exclusion criterion in these groups. The normal brightness score was determined to be 88% (mean score, 94%-2 SD) in a pilot study. Brightness discrimination test was performed in all subjects by two observers independently. BDT showed an excellent interobserver agreement (weighted Kappa 0.84). The presence of a cataract alone increased the risk of brightness impairment twofold, glaucoma alone increased the risk eightfold, and the presence of both conditions by 17 times compared to those with neither condition. BDT was not a useful test in the diagnosis of POAG (sensitivity 67% and specificity 93%); the ability to detect a significant field defect was also poor (sensitivity 53% and specificity 76%). There was poor association between decreased brightness scores and asymmetrical field defects as determined by the Humphrey's field analyzer (HFA).

  1. Reliable early opening strength for concrete pavements and patch work

    DOT National Transportation Integrated Search

    2016-06-01

    Early opening strengths for concrete vary greatly around the country for many different reasons. DOTD specifies early opening strengths and will benefit from understanding the latest thinking and practices adopted by similar agencies. Knowing the bes...

  2. Lateral displacement, sulcus angle and trochlear angle are associated with early patellofemoral osteoarthritis following anterior cruciate ligament reconstruction.

    PubMed

    Macri, Erin M; Culvenor, Adam G; Morris, Hayden G; Whitehead, Timothy S; Russell, Trevor G; Khan, Karim M; Crossley, Kay M

    2017-05-09

    Patellofemoral osteoarthritis (PFOA) occurs in approximately half of anterior cruciate ligament (ACL)-injured knees within 10-15 years of trauma. Risk factors for post-traumatic PFOA are poorly understood. Patellofemoral alignment and trochlear morphology may be associated with PFOA following ACL reconstruction (ACLR), and understanding these relationships, particularly early in the post-surgical time period, may guide effective early intervention strategies. In this study, patellofemoral alignment and trochlear morphology were investigated in relation to radiographic features of early PFOA 1-year post-ACLR. Participants (aged 18-50 years) had undergone ACLR approximately 1 year prior to being assessed. Early PFOA was defined as presence of a definite patellofemoral osteophyte on lateral or skyline radiograph. Sagittal and axial plane alignment and trochlear morphology were estimated using MRI. Using logistic regression, the relationship between alignment or morphology and presence of osteophytes was evaluated. Of 111 participants [age 30 ± 8.5; 41 (37%) women], 19 (17%) had definite osteophytes, only two of whom had had patellofemoral chondral lesions noted intra-operatively. One measure of patellar alignment (bisect offset OR 1.1 [95% confidence interval 1.0, 1.2]) and two measures of trochlear morphology (sulcus angle OR 1.1 [1.0, 1.2], trochlear angle OR 1.2 [1.0, 1.5]) were associated with patellofemoral osteophytes. Patellofemoral malalignment and/or altered trochlear morphology were associated with PFOA 1 year following ACLR compared to individuals post-ACLR without these features. Clarifying the role of alignment and morphology in post-traumatic PFOA may contribute to improving early intervention strategies aimed at secondary prevention. IV.

  3. The effectiveness of early lens extraction with intraocular lens implantation for the treatment of primary angle-closure glaucoma (EAGLE): study protocol for a randomized controlled trial.

    PubMed

    Azuara-Blanco, Augusto; Burr, Jennifer M; Cochran, Claire; Ramsay, Craig; Vale, Luke; Foster, Paul; Friedman, David; Quayyum, Zahidul; Lai, Jimmy; Nolan, Winnie; Aung, Tin; Chew, Paul; McPherson, Gladys; McDonald, Alison; Norrie, John

    2011-05-23

    Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care.EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care. EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible.The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events.A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of

  4. The effectiveness of early lens extraction with intraocular lens implantation for the treatment of primary angle-closure glaucoma (EAGLE): study protocol for a randomized controlled trial

    PubMed Central

    2011-01-01

    Background Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care. EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care. Methods/Design EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible. The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events. A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean

  5. Role of oxidative stress enzymes in open-angle glaucoma.

    PubMed

    Yildirim, O; Ateş, N A; Ercan, B; Muşlu, N; Unlü, A; Tamer, L; Atik, U; Kanik, A

    2005-05-01

    To investigate the role of oxidative stress and lipid peroxidation in the pathogenesis of primary open-angle glaucoma (POAG). The activities of myeloperoxidase (MPO), catalase (CAT), and the levels of plasma malondialdehyde (MDA) were measured in 40 (15 men and 25 women) patients with POAG and 60 (30 men and 30 women) healthy controls. There was no significant difference in the activities of CAT and MPO between the POAG patients and the controls. However, the plasma MDA level was significantly higher in patients than the controls. The results of this preliminary study suggest that the possible alterations of plasma MDA levels may be associated with the pathogenesis of POAG, but further research is needed to understand the role of oxidative damage in this important disorder of aging.

  6. The Impact of Open Licensing on the Early Reader Ecosystem

    ERIC Educational Resources Information Center

    Butcher, Neil; Hoosen, Sarah; Levey, Lisbeth; Moore, Derek

    2016-01-01

    The Impact of Open Licensing on the Early Reader Ecosystem examines how to use open licensing to promote quality learning resources for young children that are relevant and interesting. Research in early reading tends to focus on traditional publishing value and supply chains, without taking much consideration of new approaches and solutions…

  7. Comparison of Dimensional Accuracy between Open-Tray and Closed-Tray Implant Impression Technique in 15° Angled Implants

    PubMed Central

    Balouch, F; Jalalian, E; Nikkheslat, M; Ghavamian, R; Toopchi, Sh; Jallalian, F; Jalalian, S

    2013-01-01

    Statement of Problem: Various impression techniques have different effects on the accuracy of final cast dimensions. Meanwhile; there are some controversies about the best technique. Purpose: This study was performed to compare two kinds of implant impression methods (open tray and closed tray) on 15 degree angled implants. Materials and Method: In this experimental study, a steel model with 8 cm in diameter and 3 cm in height were produced with 3 holes devised inside to stabilize 3 implants. The central implant was straight and the other two implants were 15° angled. The two angled implants had 5 cm distance from each other and 3.5 cm from the central implant. Dental stone, high strength (type IV) was used for the main casts. Impression trays were filled with poly ether, and then the two impression techniques (open tray and closed tray) were compared. To evaluate positions of the implants, each cast was analyzed by CMM device in 3 dimensions (x,y,z). Differences in the measurements obtained from final casts and laboratory model were analyzed using t-Test. Results: The obtained results indicated that closed tray impression technique was significantly different in dimensional accuracy when compared with open tray method. Dimensional changes were 129 ± 37μ and 143.5 ± 43.67μ in closed tray and open tray, while coefficient of variation in closed- tray and open tray were reported to be 27.2% and 30.4%, respectively. Conclusion: Closed impression technique had less dimensional changes in comparison with open tray method, so this study suggests that closed tray impression technique is more accurate. PMID:24724130

  8. Open-loop GPS signal tracking at low elevation angles from a ground-based observation site

    NASA Astrophysics Data System (ADS)

    Beyerle, Georg; Zus, Florian

    2016-04-01

    For more than a decade space-based global navigation satellite system (GNSS) radio occultation (RO) observations are used by meteorological services world-wide for their numerical weather prediction models. In addition, climate studies increasingly rely on validated GNSS-RO data sets of atmospheric parameters. GNSS-RO profiles typically cover an altitude range from the boundary layer up to the upper stratosphere; their highest accuracy and precision, however, are attained at the tropopause level. In the lower troposphere, multipath ray propagation tend to induce signal amplitude and frequency fluctuations which lead to the development and implementation of open-loop signal tracking methods in GNSS-RO receiver firmwares. In open-loop mode the feed-back values for the carrier tracking loop are derived not from measured data, but from a Doppler frequency model which usually is extracted from an atmospheric climatology. In order to ensure that this receiver-internal parameter set, does not bias the carrier phase path observables, dual-channel open-loop GNSS-RO signal tracking was suggested. Following this proposal the ground-based "GLESER" (GPS low-elevation setting event recorder) campaign was established. Its objective was to disproof the existence of model-induced frequency biases using ground-based GPS observations at very low elevation angles. Between January and December 2014 about 2600 validated setting events, starting at geometric elevation angles of +2° and extending to -1°… - 1.5°, were recorded by the single frequency "OpenGPS" GPS receiver at a measurement site located close to Potsdam, Germany (52.3808°N, 13.0642°E). The study is based on the assumption that these ground-based observations may be used as proxies for space-based RO measurements, even if the latter occur on a one order of magnitude faster temporal scale. The "GLESER" data analysis shows that the open-loop Doppler model has negligible influence on the derived frequency profile

  9. Comparison of patrons of hotels with early opening and standard hours.

    PubMed

    Smith, D I

    1986-02-01

    A comparison was made of 72 men who were patrons in hotels with 6 A.M. or 7 A.M. opening, with a control group of 87 men interviewed in nearby hotels with 10 A.M. opening. The two groups were very similar on biographical characteristics, yet the men in the early-opening group consumed significantly more alcohol, had more drinking sessions, spent longer in drinking, and had significantly higher SMAST scores. The early opening was apparently facilitating problem drinking.

  10. Retcam fluorescein gonioangiography: a new modality for early detection of angle neovascularization in diabetic retinopathy.

    PubMed

    Azad, Rajvardhan; Arora, Tarun; Sihota, Ramanjit; Chandra, Parijat; Mahajan, Deepankur; Sain, Siddarth; Sharma, Yograj

    2013-10-01

    To evaluate the role of Retcam fluorescein gonioangiography in detecting neovascularization of the angle and correlate the same with gonioscopy in diabetic retinopathy. One hundred and fifty eyes of 150 patients (25 each of mild, moderate, severe, very severe nonproliferative diabetic retinopathy (NPDR) proliferative diabetic retinopathy (PDR); and PDR with high-risk characteristics) were recruited. They underwent complete ocular examination including applanation tonometry, gonioscopy, Retcam fluorescein gonioangiography, and fundus fluorescein angiography. Using Retcam fluorescein gonioangiography, of 150 eyes neovascularization of the angle was detected in 37 eyes (24.66%) compared with 22 eyes (14.66%) on gonioscopy (P = 0.04). Small newly formed vessels were evident only with Retcam fluorescein gonioangiography. In 10 of 50 patients (20%) with severe/very severe NPDR, angle neovascularization was appreciable on Retcam fluorescein angiography compared with 5 patients (10%) on gonioscopy. Similarly, 25 of 50 patients (50%) with PDR/PDR with high-risk characteristics had neovascularization of the angle on Retcam gonioangiography compared with 17 (34%) on gonioscopy. Retcam fluorescein gonioangiography is a novel technique for early detection of angle neovascularization in diabetic retinopathy and hence preventing progression to neovascular glaucoma. The objective nature of this test helps in precise decision making compared with gonioscopy for early intervention especially in cases of pre-PDR.

  11. Open Listening: Creative Evolution in Early Childhood Settings

    ERIC Educational Resources Information Center

    Davies, Bronwyn

    2011-01-01

    This article sketches out a philosophy and practice of open listening, linking open listening to Bergson's (1998) concept of creative evolution. I draw on examples of small children at play from a variety of sources, including Reggio-Emilia-inspired preschools in Sweden. The article offers a challenge to early childhood educators to listen and to…

  12. Characterizing the “POAGome”: A bioinformatics-driven approach to primary open-angle glaucoma

    PubMed Central

    Danford, Ian D.; Verkuil, Lana D.; Choi, Daniel J.; Collins, David W.; Gudiseva, Harini V.; Uyhazi, Katherine E.; Lau, Marisa K.; Kanu, Levi N.; Grant, Gregory R.; Chavali, Venkata R.M.; O’Brien, Joan M.

    2017-01-01

    Primary open-angle glaucoma (POAG) is a genetically, physiologically, and phenotypically complex neurodegenerative disorder. This study addressed the expanding collection of genes associated with POAG, referred to as the “POAGome.” We used bioinformatics tools to perform an extensive, systematic literature search and compiled 542 genes with confirmed associations with POAG and its related phenotypes (normal tension glaucoma, ocular hypertension, juvenile open-angle glaucoma, and primary congenital glaucoma). The genes were classified according to their associated ocular tissues and phenotypes, and functional annotation and pathway analyses were subsequently performed. Our study reveals that no single molecular pathway can encompass the pathophysiology of POAG. The analyses suggested that inflammation and senescence may play pivotal roles in both the development and perpetuation of the retinal ganglion cell degeneration seen in POAG. The TGF-β signaling pathway was repeatedly implicated in our analyses, suggesting that it may be an important contributor to the manifestation of POAG in the anterior and posterior segments of the globe. We propose a molecular model of POAG revolving around TGF-β signaling, which incorporates the roles of inflammation and senescence in this disease. Finally, we highlight emerging molecular therapies that show promise for treating POAG. PMID:28223208

  13. Juxtacanalicular tissue in pigmentary and primary open angle glaucoma. The hydrodynamic role of pigment and other constituents.

    PubMed

    Murphy, C G; Johnson, M; Alvarado, J A

    1992-12-01

    We tested the hypothesis that obstruction of the juxtacanalicular tissues, by melanin granules in pigmentary glaucoma and by other impermeable material in primary open angle glaucoma, leads to the development of a chronic glaucomatous condition. The distribution and concentration of melanin and other impermeable materials in the juxtacanalicular tissues and elsewhere in the trabecular meshwork was determined in 13 specimens. Six specimens were from patients with pigmentary glaucoma, two from patients with pigment dispersion syndrome, and three from patients with primary open angle glaucoma, as well as two from normal subjects. The effect of these materials on flow resistance was estimated using two hydrodynamic models. In model A, the electron-lucent spaces of the juxtacanalicular tissue were assumed to be open spaces, while in model B, these spaces and spaces filled with ground substance were assumed to be gel filled. In pigmentary glaucoma, 3.5% of the pigment was found in the juxtacanalicular tissue, while 96.5% was found in the corneoscleral and uveoscleral tissues. Permeabilities calculated according to model A were much higher than those expected from estimates of outflow facility in all groups, in agreement with the previous report of Ethier et al. The gel-filled spaces available for fluid flow, as determined by model B, showed no statistically demonstrable differences (pigmentary glaucoma, 32.9%; primary open angle glaucoma, 36.6%; pigment dispersion syndrome, 43.4%; normal, 44.1%). Furthermore, the amount of pigment present in the juxtacanalicular tissue was determined to have a negligible influence on permeability. Thus, the development of the chronic glaucomatous condition cannot be directly attributed to pigment accumulation in the juxtacanalicular tissue in pigmentary glaucoma.

  14. [Predicting the probability of development and progression of primary open angle glaucoma by regression modeling].

    PubMed

    Likhvantseva, V G; Sokolov, V A; Levanova, O N; Kovelenova, I V

    2018-01-01

    Prediction of the clinical course of primary open-angle glaucoma (POAG) is one of the main directions in solving the problem of vision loss prevention and stabilization of the pathological process. Simple statistical methods of correlation analysis show the extent of each risk factor's impact, but do not indicate the total impact of these factors in personalized combinations. The relationships between the risk factors is subject to correlation and regression analysis. The regression equation represents the dependence of the mathematical expectation of the resulting sign on the combination of factor signs. To develop a technique for predicting the probability of development and progression of primary open-angle glaucoma based on a personalized combination of risk factors by linear multivariate regression analysis. The study included 66 patients (23 female and 43 male; 132 eyes) with newly diagnosed primary open-angle glaucoma. The control group consisted of 14 patients (8 male and 6 female). Standard ophthalmic examination was supplemented with biochemical study of lacrimal fluid. Concentration of matrix metalloproteinase MMP-2 and MMP-9 in tear fluid in both eyes was determined using 'sandwich' enzyme-linked immunosorbent assay (ELISA) method. The study resulted in the development of regression equations and step-by-step multivariate logistic models that can help calculate the risk of development and progression of POAG. Those models are based on expert evaluation of clinical and instrumental indicators of hydrodynamic disturbances (coefficient of outflow ease - C, volume of intraocular fluid secretion - F, fluctuation of intraocular pressure), as well as personalized morphometric parameters of the retina (central retinal thickness in the macular area) and concentration of MMP-2 and MMP-9 in the tear film. The newly developed regression equations are highly informative and can be a reliable tool for studying of the influence vector and assessment of pathogenic

  15. Genetics Home Reference: early-onset glaucoma

    MedlinePlus

    ... called a syndrome. If glaucoma appears before the age of 5 without other associated abnormalities, it is called primary congenital glaucoma. Other individuals experience early onset of primary open-angle glaucoma, the most ...

  16. Glymphatic stasis at the site of the lamina cribrosa as a potential mechanism underlying open-angle glaucoma.

    PubMed

    Wostyn, Peter; Killer, Hanspeter Esriel; De Deyn, Peter Paul

    2017-07-01

    The underlying pathophysiology of primary open-angle glaucoma remains unclear, but the lamina cribrosa seems to be the primary site of injury, and raised intraocular pressure is a major risk factor. In recent years, a decreased intracranial pressure, leading to an abnormally high trans-lamina cribrosa pressure difference, has gained interest as a new risk factor for glaucoma. New research now lends support to the hypothesis that a paravascular transport system is present in the eye analogous to the recently discovered 'glymphatic system' in the brain, which is a functional waste clearance pathway that promotes elimination of interstitial solutes, including β-amyloid, from the brain along paravascular channels. Given that β-amyloid has been reported to increase by chronic elevation of intraocular pressure in glaucomatous animal models and to cause retinal ganglion cell death, the discovery of a paravascular clearance system in the eye may provide powerful new insights into the pathophysiology of primary open-angle glaucoma. In this review, we provide a new conceptual framework for understanding the pathogenesis of primary open-angle glaucoma, present supporting preliminary data from our own post-mortem study and hypothesize that the disease may result from restriction of normal glymphatic flow at the level of the lamina cribrosa owing to a low intracranial pressure and/or a high trans-lamina cribrosa pressure gradient. If confirmed, this viewpoint could offer new perspectives for the development of novel diagnostic and therapeutic strategies for this devastating disorder. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  17. Evaluation of retinal ganglion cell function after intraocular pressure reduction measured by pattern electroretinogram in patients with primary open-angle glaucoma.

    PubMed

    Karaśkiewicz, Joanna; Penkala, Krzysztof; Mularczyk, Maciej; Lubiński, Wojciech

    2017-04-01

    To evaluate retinal ganglion cell (RGC) function after intraocular pressure (IOP) reduction measured by pattern electroretinogram (PERG) in patients with newly diagnosed, non-treated preperimetric and early stages of primary open-angle glaucoma (POAG). Twenty-four eyes from 24 patients with POAG: 11 eyes with preperimetric glaucoma and 13 eyes with early glaucoma received Ganfort ® (bimatoprost + timolol) once a day for a period of 1 month. Before and after the treatment, following measurements were analyzed: IOP, mean ocular perfusion pressure (MOPP), peak time of P50 and amplitude of P50 and N95 waves in PERG (ISCEV standard 2012). Correlations between PERG P50 and N95 waves, IOP and MOPP were calculated. After therapy, IOP significantly decreased in all eyes, on average 31%. Significant increase in MOPP in all eyes on average 14% was detected. PERG amplitude of P50 and N95 waves increased in 75 and 79% eyes, respectively, on average P50 by 28% and N95 by 38%. There were no significant interactions between the change of PERG parameters in time and stage of glaucoma. Significant IOP-lowering therapy can improve RGC function measured by PERG, in patients with preperimetric and early stages of POAG.

  18. Middle Jurassic - Early Cretaceous rifting on the Chortis Block in Honduras: Implications for proto-Caribbean opening (Invited)

    NASA Astrophysics Data System (ADS)

    Rogers, R. D.; Emmet, P. A.

    2009-12-01

    Regional mapping integrated with facies analysis, age constraints and airborne geophysical data reveal WNW and NE trends of Middle Jurassic to Early Cretaceous basins which intersect in southeast Honduras that we interpret as the result of rifting associated with the breakup of the Americas and opening of the proto-Caribbean seaway. The WNW-trending rift is 250 km long by 90 km wide and defined by a basal 200 to 800 m thick sequence of Middle to Late Jurassic fluvial channel and overbank deposits overlain by transgressive clastic shelf strata. At least three sub-basins are apparent. Flanking the WNW trending rift basins are fault bounded exposures of the pre-Jurassic continental basement of the Chortis block which is the source of the conglomeratic channel facies that delineate the axes of the rifts. Cretaceous terrigenous strata mantle the exposed basement-cored rift flanks. Lower Cretaceous clastic strata and shallow marine limestone strata are dominant along this trend indicating that post-rift related subsidence continued through the Early Cretaceous. The rifts coincide with a regional high in the total magnetic intensity data. We interpret these trends to reflect NNE-WSW extension active from the Middle Jurassic through Early Cretaceous. These rifts were inverted during Late Cretaceous shortening oriented normal to the rift axes. To the east and at a 120 degree angle to the WNW trending rift is the 300 km long NE trending Guayape fault system that forms the western shoulder of the Late Jurassic Agua Fria rift basin filled by > 2 km thickness of clastic marine shelf and slope strata. This NE trending basin coincides with the eastern extent of the surface exposure of continental basement rocks and a northeast-trending fabric of the Jurassic (?) metasedimentary basement rocks. We have previously interpreted the eastern basin to be the Jurassic rifted margin of the Chortis block with the Guayape originating as a normal fault system. These two rifts basin intersect

  19. Comparison of Pattern Electroretinography and Optical Coherence Tomography Parameters in Patients with Primary Open-Angle Glaucoma and Ocular Hypertension

    PubMed Central

    Tiryaki Demir, Semra; Oba, Mehmet Ersin; Erdoğan, Ezgi Tuna; Odabaşı, Mahmut; Dirim, Ayşe Burcu; Demir, Mehmet; Can, Efe; Kara, Orhan; Yekta Şendül, Selam

    2015-01-01

    Objectives: To investigate the correlation of visual field (VF), pattern electroretinography (PERG) and Fourier domain optical coherence tomography (FD-OCT) results in patients with ocular hypertension (OHT) and early primary open-angle glaucoma (POAG). Materials and Methods: The study included 72 eyes of 37 patients with early POAG, 76 eyes of 38 patients with OHT, and 60 eyes of 30 controls. All subjects underwent full ophthalmologic examination, VF assessment with 24-2 Humphrey standard automated perimetry (Swedish Interactive Thresholding Algorithm (SITA)-Standard), retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) thickness measurement with FD-OCT, and PERG P50 and N95 wave latency and amplitude measurements with electroretinography (Nihon Kohden). Results: With the exception of the nasal quadrant, all GCC parameters and RNFL results were significantly lower in the POAG group compared to the OHT and control groups. There was no statistically significant difference between the OHT and control group. PERG amplitudes were lower in the POAG and OHT groups than in the control group. Reduction in N95 amplitude was greater than that of P50 amplitude. No difference was detected in PERG latencies among groups. GCC was significantly correlated with VF and RNFL in the POAG group. Conclusion: Significant thinning of the GCC and RNFL occurs in addition to VF pathologies in patients with early POAG, and these examinations should be concomitantly evaluated. During diagnostic assessment of patients with early POAG, GCC and RNFL analysis by FD-OCT are highly effective. GCC is as reliable as RNLF in the early diagnosis of glaucoma and there is a highly significant correlation between them. Dysfunction of ganglion cells in patients with OHT may be detected earlier using PERG amplitude analysis. PMID:27800239

  20. Establishing Age-Adjusted Reference Ranges for Iris-Related Parameters in Open Angle Eyes with Anterior Segment Optical Coherence Tomography.

    PubMed

    Peterson, Jeffrey R; Blieden, Lauren S; Chuang, Alice Z; Baker, Laura A; Rigi, Mohammed; Feldman, Robert M; Bell, Nicholas P

    2016-01-01

    Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT). Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18-35, 36-45, 46-55, 56-65, and 66-79 years). ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan) and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL), length of scleral spur landmark (SSL) to pupillary margin (SSL-to-PM), iris contour ratio (ICR = AISL/SSL-to-PM), pupil radius, radius of iris centroid (RICe), and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter. Mean (±SD) values were 2.24 mm (±0.46), 4.06 mm (±0.27), 3.65 mm (±0.48), 4.16 mm (±0.47), 1.14 (±0.04), 1.51 mm2 (±0.23), and 38.42 μL (±4.91) for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002) and RICe (P = 0.027) decreased with age, while SSL-to-PM (P = 0.002) and AISL increased with age (P = 0.001). ICR (P = 0.54) and iris volume (P = 0.49) were not affected by age. This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states.

  1. Brain-Derived Neurotrophic Factor in Patients with Primary Open-Angle Glaucoma and Age-related Cataract.

    PubMed

    Shpak, Alexander A; Guekht, Alla B; Druzhkova, Tatiana A; Kozlova, Ksenia I; Gulyaeva, Natalia V

    2018-02-01

    To study brain-derived neurotrophic factor (BDNF) content in aqueous humor (AH), lacrimal fluid (LF), and blood serum (BS) in patients with age-related cataract and primary open-angle glaucoma (POAG). BDNF was studied in 57 patients with age-related cataract, 55 patients with POAG combined with cataract, and 29 healthy controls (one eye in each person). AH was sampled during cataract surgery. The levels of BDNF in LF and BS did not differ in cataract patients and controls. The concentration of BDNF (pg/mL) in patients with POAG and cataract was lower than in cataract patients in AH (35.2 ± 14.2 vs. 54.6 ± 29.6, P < 0.001), LF (78.0 ± 25.1 vs. 116.2 ± 43.1, P < 0.001), and BS (19230 ± 5960 vs. 22440 ± 7580, P < 0.02), while the AH/LF ratio was similar (0.46 ± 0.18 vs. 0.48 ± 0.19). The AH level of BDNF declined in early POAG and relatively increased in the next stages of the disease, inversely correlating with visual field index (Pearson's correlation coefficient r = -0.404, P = 0.002) and average retinal nerve fiber layer thickness (r = -0.322, P = 0.018). BDNF contents in LF and BS were also the lowest in early POAG. BDNF in AH strongly correlated with its content in LF (r = 0.66, P < 0.000). A formula was suggested to calculate the AH concentration of BDNF basing on its content in LF. BDNF contents are decreased in AH, LF, and BS of patients with POAG demonstrating a significant decrease in the early POAG and relative increase in the next stages of the disease. A strong correlation exists between BDNF contents in AH and LF.

  2. Using Digital Technology to See Angles from Different Angles. Part 2: Openings and Turns

    ERIC Educational Resources Information Center

    Host, Erin; Baynham, Emily; McMaster, Heather

    2015-01-01

    Ever wondered how to use technology to teach angles? This article follows on from an earlier article published last year, providing a range of ideas for integrating technology and concrete materials with the teaching of angle concepts. The authors also provide a comprehensive list of free online games and learning objects that can be used to teach…

  3. Effect of the meniscus contact angle during early regimes of spontaneous imbibition in nanochannels.

    PubMed

    Karna, Nabin Kumar; Oyarzua, Elton; Walther, Jens H; Zambrano, Harvey A

    2016-11-30

    Nanoscale capillarity has been extensively investigated; nevertheless, many fundamental questions remain open. In spontaneous imbibition, the classical Lucas-Washburn equation predicts a singularity as the fluid enters the channel consisting of an anomalous infinite velocity of the capillary meniscus. Bosanquet's equation overcomes this problem by taking into account fluid inertia predicting an initial imbibition regime with constant velocity. Nevertheless, the initial constant velocity as predicted by Bosanquet's equation is much greater than those observed experimentally. In the present study, large scale atomistic simulations are conducted to investigate capillary imbibition of water in slit silica nanochannels with heights between 4 and 18 nm. We find that the meniscus contact angle remains constant during the inertial regime and its value depends on the height of the channel. We also find that the meniscus velocity computed at the channel entrance is related to the particular value of the meniscus contact angle. Moreover, during the subsequent visco-inertial regime, as the influence of viscosity increases, the meniscus contact angle is found to be time dependent for all the channels under study. Furthermore, we propose an expression for the time evolution of the dynamic contact angle in nanochannels which, when incorporated into Bosanquet's equation, satisfactorily explains the initial capillary rise.

  4. A Relationship Between Constraint and the Critical Crack Tip Opening Angle

    NASA Technical Reports Server (NTRS)

    Johnston, William M.; James, Mark A.

    2009-01-01

    Of the various approaches used to model and predict fracture, the Crack Tip Opening Angle (CTOA) fracture criterion has been successfully used for a wide range of two-dimensional thin-sheet and thin plate applications. As thicker structure is considered, modeling the full three-dimensional fracture process will become essential. This paper investigates relationships between the local CTOA evaluated along a three-dimensional crack front and the corresponding local constraint. Previously reported tunneling crack front shapes were measured during fracture by pausing each test and fatigue cycling the specimens to mark the crack surface. Finite element analyses were run to model the tunneling shape during fracture, with the analysis loading conditions duplicating those tests. The results show an inverse relationship between the critical fracture value and constraint which is valid both before maximum load and after maximum load.

  5. [Psychosomatic symptoms in somatic diseases - open-angle glaucoma for example].

    PubMed

    Emmerich, G M

    2010-08-01

    Psychological aspects exist in somatic diseases like tumours and even fractures, not only in the beginning but also in the management of disease. Somatic diseases give rise to signs of a special constellation of life and management of these diseases is important for the psychological constellation of the individual. Studies on open-angle glaucoma have shown that many patients suffering from this disease are anxious, hypochondric, perfectionist and emotional instable. Chronic diseases are demanding processes of flexibility and defense, and define how the individual can deal with the diseases and what place in life the disease will occupy in the future. In the holistic view of medicine even psychological conflicts should be treated. In many situations, these conflicts are not consciously experienced by the individual. Therapeutically, 2 different tools can be used: symbolic stories can bring forces to manage the conflict and to solve the conflict (2 examples in the text). The method of positive psychotherapy describes the reasons for psychosomatic diseases in three parts: psychosomatic in the traditional understanding, in further and comprehensive understanding. Especially the psychosomatic effects in comprehensive understanding are embedded in the individual's sociocultural environment and provide tips on reasons for the diseases in those parts of life. The "positive balance model" gives an example of life-management and conflict-therapy. In ophthalmology, fear is often more important for the patient than pain. To avoid this, the patients develop techniques to deny, to cover or to suppress the fear. In the article questions are presented like those the ophthalmologist should be able to ask patients in the office concerning open-angle glaucoma. Tips for the therapy and management for neurotic stress are offered and some special anamnestic questions for the ophthalmologist are presented. Unsolved conflicts and denied desires as neurotic symptoms can be focused in

  6. Anterior Segment Imaging Predicts Incident Gonioscopic Angle Closure.

    PubMed

    Baskaran, Mani; Iyer, Jayant V; Narayanaswamy, Arun K; He, Yingke; Sakata, Lisandro M; Wu, Renyi; Liu, Dianna; Nongpiur, Monisha E; Friedman, David S; Aung, Tin

    2015-12-01

    To investigate the incidence of gonioscopic angle closure after 4 years in subjects with gonioscopically open angles but varying degrees of angle closure detected on anterior segment optical coherence tomography (AS OCT; Visante; Carl Zeiss Meditec, Dublin, CA) at baseline. Prospective, observational study. Three hundred forty-two subjects, mostly Chinese, 50 years of age or older, were recruited, of whom 65 were controls with open angles on gonioscopy and AS OCT at baseline, and 277 were cases with baseline open angles on gonioscopy but closed angles (1-4 quadrants) on AS OCT scans. All subjects underwent gonioscopy and AS OCT at baseline (horizontal and vertical single scans) and after 4 years. The examiner performing gonioscopy was masked to the baseline and AS OCT data. Angle closure in a quadrant was defined as nonvisibility of the posterior trabecular meshwork by gonioscopy and visible iridotrabecular contact beyond the scleral spur in AS OCT scans. Gonioscopic angle closure in 2 or 3 quadrants after 4 years. There were no statistically significant differences in age, ethnicity, or gender between cases and controls. None of the control subjects demonstrated gonioscopic angle closure after 4 years. Forty-eight of the 277 subjects (17.3%; 95% confidence interval [CI], 12.8-23; P < 0.0001) with at least 1 quadrant of angle closure on AS OCT at baseline demonstrated gonioscopic angle closure in 2 or more quadrants, whereas 28 subjects (10.1%; 95% CI, 6.7-14.6; P < 0.004) demonstrated gonioscopic angle closure in 3 or more quadrants after 4 years. Individuals with more quadrants of angle closure on baseline AS OCT scans had a greater likelihood of gonioscopic angle closure developing after 4 years (P < 0.0001, chi-square test for trend for both definitions of angle closure). Anterior segment OCT imaging at baseline predicts incident gonioscopic angle closure after 4 years among subjects who have gonioscopically open angles and iridotrabecular contact on AS OCT at

  7. Establishing Age-Adjusted Reference Ranges for Iris-Related Parameters in Open Angle Eyes with Anterior Segment Optical Coherence Tomography

    PubMed Central

    Peterson, Jeffrey R.; Blieden, Lauren S.; Chuang, Alice Z.; Baker, Laura A.; Rigi, Mohammed; Feldman, Robert M.; Bell, Nicholas P.

    2016-01-01

    Purpose Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT). Methods Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18–35, 36–45, 46–55, 56–65, and 66–79 years). ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan) and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL), length of scleral spur landmark (SSL) to pupillary margin (SSL-to-PM), iris contour ratio (ICR = AISL/SSL-to-PM), pupil radius, radius of iris centroid (RICe), and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter. Results Mean (±SD) values were 2.24 mm (±0.46), 4.06 mm (±0.27), 3.65 mm (±0.48), 4.16 mm (±0.47), 1.14 (±0.04), 1.51 mm2 (±0.23), and 38.42 μL (±4.91) for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002) and RICe (P = 0.027) decreased with age, while SSL-to-PM (P = 0.002) and AISL increased with age (P = 0.001). ICR (P = 0.54) and iris volume (P = 0.49) were not affected by age. Conclusion This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states. PMID:26815917

  8. Multifocal visual evoked potentials for early glaucoma detection.

    PubMed

    Weizer, Jennifer S; Musch, David C; Niziol, Leslie M; Khan, Naheed W

    2012-07-01

    To compare multifocal visual evoked potentials (mfVEP) with other detection methods in early open-angle glaucoma. Ten patients with suspected glaucoma and 5 with early open-angle glaucoma underwent mfVEP, standard automated perimetry (SAP), short-wave automated perimetry, frequency-doubling technology perimetry, and nerve fiber layer optical coherence tomography. Nineteen healthy control subjects underwent mfVEP and SAP for comparison. Comparisons between groups involving continuous variables were made using independent t tests; for categorical variables, Fisher's exact test was used. Monocular mfVEP cluster defects were associated with an increased SAP pattern standard deviation (P = .0195). Visual fields that showed interocular mfVEP cluster defects were more likely to also show superior quadrant nerve fiber layer thinning by OCT (P = .0152). Multifocal visual evoked potential cluster defects are associated with a functional and an anatomic measure that both relate to glaucomatous optic neuropathy. Copyright 2012, SLACK Incorporated.

  9. The importance of early operative treatment in open fractures of the fingers.

    PubMed

    Ng, Tim; Unadkat, Jignesh; Bilonick, Richard A; Wollstein, Ronit

    2014-04-01

    Current guidelines suggest early surgical treatment of open fractures. This rule in open hand fractures is not well supported and may be practically difficult to observe. Furthermore, desirable washout can be obtained in the emergency department (ED). The purpose of this study was to determine the importance of early surgery in our institution. Seventy patients with open fractures of the hand were retrospectively reviewed for demographics, fracture characteristics, and complications. Statistical analysis included univariate analysis, Fisher exact test, and Akaike information criterion. Intravenous antibiotics were administered early in 53 (75.7%) patients. Mean (SD) time to surgery was 2.3 (134.9) hours. The infection rate was 11.4%. No significant relationship was found between fracture type, finger involved, hand dominance, comorbidities, and infection. Antibiotic administration was significantly related to infection (P = 0.007), whereas time to surgery was not (P = 0.33). Age was weakly related to infection (P = 0.08). Administration of intravenous antibiotics in the ED was the most significant factor in preventing infection, whereas the time to operation was not significant. Because a thorough washout and debridement can be performed on open hand fractures in the ED due to the ability to provide adequate anesthesia, the actual time to surgery may possibly be delayed without increasing the risk of infection. Future prospective studies may allow for better guidelines for the treatment of open hand fractures.

  10. [Effects of nootropic agents on visual functions and lacrimal antioxidative activity in patients with primary open-angle glaucoma].

    PubMed

    Davydova, N G; Kuznetsova, T P; Borisova, S A; Abdulkadyrova, M Zh

    2006-01-01

    The paper presents the results of an investigation of the effect of the nootropic agents pantogam and nooclerine on visual functions in patients with primary open-angle glaucoma. These agents have been found to have a beneficial effect on the functional activity of the retina and optic nerve, light sensitivity, hemo- and hydrodynamics of the eye.

  11. Structure-function correlations using scanning laser polarimetry in primary angle-closure glaucoma and primary open-angle glaucoma.

    PubMed

    Lee, Pei-Jung; Liu, Catherine Jui-Ling; Wojciechowski, Robert; Bailey-Wilson, Joan E; Cheng, Ching-Yu

    2010-05-01

    To assess the correlations between retinal nerve fiber layer (RNFL) thickness measured with scanning laser polarimetry and visual field (VF) sensitivity in primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG). Prospective, comparative, observational cases series. Fifty patients with POAG and 56 patients with PACG were examined using scanning laser polarimetry with variable corneal compensation (GDx VCC; Laser Diagnostic Technologies, Inc.) and Humphrey VF analyzer (Carl Zeiss Meditec, Inc.) between August 2005 and July 2006 at Taipei Veterans General Hospital. Correlations between RNFL thickness and VF sensitivity, expressed as mean sensitivity in both decibel and 1/Lambert scales, were estimated by the Spearman rank correlation coefficient (r(s)) and multivariate median regression models (pseudo R(2)). The correlations were determined globally and for 6 RNFL sectors and their corresponding VF regions. The correlation between RNFL thickness and mean sensitivity (in decibels) was weaker in the PACG group (r(s) = 0.38; P = .004; pseudo R(2) = 0.17) than in the POAG group (r(s) = 0.51; P < .001; pseudo R(2) = .31), but the difference in the magnitude of correlation was not significant (P = .42). With Bonferroni correction, the structure-function correlation was significant in the superotemporal (r(s) = 0.62), superonasal (r(s) = 0.56), inferonasal (r(s) = 0.53), and inferotemporal (r(s) = 0.50) sectors in the POAG group (all P < .001), whereas it was significant only in the superotemporal (r(s) = 0.53) and inferotemporal (r(s) = 0.48) sectors in the PACG group (both P < .001). The results were similar when mean sensitivity was expressed as 1/Lambert scale. Both POAG and PACG eyes had moderate structure-function correlations using scanning laser polarimetry. Compared with eyes with POAG, fewer RNFL sectors have significant structure-function correlations in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  12. Structure-Function Correlations using Scanning Laser Polarimetry in Primary Angle-Closure Glaucoma and Primary Open Angle Glaucoma

    PubMed Central

    Lee, Pei-Jung; Liu, Catherine Jui-Ling.; Wojciechowski, Robert; Bailey-Wilson, Joan E.; Cheng, Ching-Yu

    2010-01-01

    Purpose To assess the correlations between retinal nerve fiber layer (RNFL) thickness measured with scanning laser polarimetry (SLP) and visual field (VF) sensitivity in primary open angle glaucoma (POAG) and primary angle-closure glaucoma (PACG). Design Prospective, comparative, observational cases series Methods Fifty patients with POAG and 56 with PACG were examined using SLP with variable corneal compensation (GDx VCC) and Humphrey VF analyzer between August 2005 and July 2006 at Taipei Veterans General Hospital. Correlations between RNFL thickness and VF sensitivity, expressed as mean sensitivity (MS) in both decibel (dB) and 1/Lambert (L) scales, were estimated by Spearman's rank correlation coefficient (rs) and multivariate median regression models (pseudo R2). The correlations were determined globally and for six RNFL sectors and their corresponding VF regions. Results The correlation between RNFL thickness and MS (in dB) was weaker in the PACG group (rs = 0.38, P = 0.004, pseudo R2 = 0.17) than in the POAG group (rs = 0.51, P <0.001, pseudo R2 = 0.31), but the difference in the magnitude of correlation was not significant (P = 0.42).With Bonferroni correction, the structure-function correlation was significant in the superotemporal (rs = 0.62), superonasal (rs = 0.56), inferonasal (rs = 0.53), and inferotemporal (rs = 0.50) sectors in the POAG group (all P <0.001), while it was significant only in the superotemporal (rs = 0.53) and inferotemporal (rs = 0.48) sectors in the PACG group (both P <0.001). The results were similar when MS was expressed as 1/L scale. Conclusions Both POAG and PACG eyes had moderate structure-function correlations using SLP. Compared to eyes with POAG, fewer RNFL sectors have significant structure-function correlations in eyes with PACG. PMID:20202618

  13. Morning glory syndrome associated with primary open angle glaucoma--case report.

    PubMed

    Bozić, Marija; Hentova-Senćanić, Paraskeva; Marković, Vujica; Marjanović, Ivan

    2014-01-01

    Morning glory syndrome (MGS) is a rare congenital optic disc anomaly, first reported in 1970. MGS is a nonprogressive and untreatable condition, which usually occurs as an isolated ocular anomaly, and can be associated with the increased incidence of nonrhegmatogenous retinal detachment, and also with strabismus, afferent pupillary defect, visual field defects, presence of hyaloids artery remnants, ciliary body cyst, congenital cataract, lid hemangioma and preretinal gliosis. We report a clinical case of MGS associated with primary open angle glaucoma. The use of sophisticated diagnostic tools, such as retinal tomography and visual field testing is limited if multiple eye conditions are present, since optic disc does not have "usual" appearance that can be analyzed according to standard statistical databases. In treating and follow up of glaucoma cases associated with other diseases and conditions that affect the appearance and function of the optic nerve head, sometimes the use of modern technological methods is limited due to difficult interpretation of the obtained results.

  14. Surgical Outcomes of Gonioscopy-assisted Transluminal Trabeculotomy (GATT) in Patients With Open-angle Glaucoma.

    PubMed

    Rahmatnejad, Kamran; Pruzan, Noelle L; Amanullah, Sarah; Shaukat, Bilal A; Resende, Arthur F; Waisbourd, Michael; Zhan, Tingting; Moster, Marlene R

    2017-12-01

    To evaluate the efficacy and safety of gonioscopy-assisted transluminal trabeculotomy (GATT) in patients with open-angle glaucoma. A retrospective chart review of adult patients who underwent GATT due to inadequately controlled intraocular pressure (IOP) or intolerance to medication. Main outcome measures were success rate, IOP, and number of glaucoma medications. Success was defined as IOP reduction >20% from baseline or IOP between 5 to 21 mm Hg, and no need for further glaucoma surgery. When success criteria were not met for any postoperative visit >3 months after surgery, failure was determined. In total, 66 patients, average age 62.9±14.9 years (50.8% female) were included in the analysis. Average follow-up was 11.9 months (range, 3 to 30 mo) and overall success rate was 63.0%. Mean IOP was 26.1±9.9 mm Hg preoperatively and 14.6±4.7 mm Hg at 12 months (44% IOP decrease; P<0.001). Mean number of medications decreased from 3.1±1.1 preoperatively to 1.2±0.9 at 12 months (P<0.001). No significant differences between patients with primary open-angle glaucoma and other types of glaucoma were found.The rate of hyphema at 1 week and 1 month postoperatively was 38% and 6%, respectively. Overall GATT success rate among white and black patients was 69% and 42%, respectively, which was statistically significant (P<0.05). The future of GATT as a minimally invasive glaucoma surgery in adults seems promising. This position is supported by its low rate of long-term complications and the conjunctiva-sparing nature of the surgery.

  15. Effectiveness of early lens extraction for the treatment of primary angle-closure glaucoma (EAGLE): a randomised controlled trial.

    PubMed

    Azuara-Blanco, Augusto; Burr, Jennifer; Ramsay, Craig; Cooper, David; Foster, Paul J; Friedman, David S; Scotland, Graham; Javanbakht, Mehdi; Cochrane, Claire; Norrie, John

    2016-10-01

    Primary angle-closure glaucoma is a leading cause of irreversible blindness worldwide. In early-stage disease, intraocular pressure is raised without visual loss. Because the crystalline lens has a major mechanistic role, lens extraction might be a useful initial treatment. From Jan 8, 2009, to Dec 28, 2011, we enrolled patients from 30 hospital eye services in five countries. Randomisation was done by a web-based application. Patients were assigned to undergo clear-lens extraction or receive standard care with laser peripheral iridotomy and topical medical treatment. Eligible patients were aged 50 years or older, did not have cataracts, and had newly diagnosed primary angle closure with intraocular pressure 30 mm Hg or greater or primary angle-closure glaucoma. The co-primary endpoints were patient-reported health status, intraocular pressure, and incremental cost-effectiveness ratio per quality-adjusted life-year gained 36 months after treatment. Analysis was by intention to treat. This study is registered, number ISRCTN44464607. Of 419 participants enrolled, 155 had primary angle closure and 263 primary angle-closure glaucoma. 208 were assigned to clear-lens extraction and 211 to standard care, of whom 351 (84%) had complete data on health status and 366 (87%) on intraocular pressure. The mean health status score (0·87 [SD 0·12]), assessed with the European Quality of Life-5 Dimensions questionnaire, was 0·052 higher (95% CI 0·015-0·088, p=0·005) and mean intraocular pressure (16·6 [SD 3·5] mm Hg) 1·18 mm Hg lower (95% CI -1·99 to -0·38, p=0·004) after clear-lens extraction than after standard care. The incremental cost-effectiveness ratio was £14 284 for initial lens extraction versus standard care. Irreversible loss of vision occurred in one participant who underwent clear-lens extraction and three who received standard care. No patients had serious adverse events. Clear-lens extraction showed greater efficacy and was more cost-effective than

  16. Lifetime risk of blindness in open-angle glaucoma.

    PubMed

    Peters, Dorothea; Bengtsson, Boel; Heijl, Anders

    2013-10-01

    To determine the lifetime risk and duration of blindness in patients with manifest open-angle glaucoma (OAG). Retrospective chart review. We studied glaucoma patients who died between January 2006 and June 2010. Most glaucoma patients living in the catchment area (city of Malmö; n = 305 000) are managed at the Department of Ophthalmology at Skåne University Hospital in Malmö. From the patient records we extracted visual field status, visual acuity, and low vision or blindness as defined by the World Health Organization (WHO) criteria and caused by glaucoma at the time of diagnosis and during follow-up. We also noted age at diagnosis and death and when low vision or blindness occurred. Five hundred and ninety-two patients were included. At the time of the last visit 250 patients (42.2%) had at least 1 blind eye because of glaucoma, while 97 patients (16.4%) were bilaterally blind, and 12 patients (0.5%) had low vision. Median time with a glaucoma diagnosis was 12 years (<1-29), median age when developing bilateral blindness was 86 years, and median duration of bilateral blindness was 2 years (<1-13). The cumulative incidences of blindness in at least 1 eye and bilateral blindness from glaucoma were 26.5% and 5.5%, respectively, after 10 years, and 38.1% and 13.5% at 20 years. Approximately 1 out of 6 glaucoma patients was bilaterally blind from glaucoma at the last visit. Median duration of bilateral blindness was 2 years. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Influence of crack opening and incident wave angle on second harmonic generation of Lamb waves

    NASA Astrophysics Data System (ADS)

    Yang, Yi; Ng, Ching-Tai; Kotousov, Andrei

    2018-05-01

    Techniques utilising second harmonic generation (SHG) have proven their great potential in detecting contact-type damage. However, the gap between the practical applications and laboratory studies is still quite large. The current work is aimed to bridge this gap by investigating the effects of the applied load and incident wave angle on the detectability of fatigue cracks at various lengths. Both effects are critical for practical implementations of these techniques. The present experimental study supported by three-dimensional (3D) finite element (FE) modelling has demonstrated that the applied load, which changes the crack opening and, subsequently, the contact nonlinearity, significantly affects the amplitude of the second harmonic generated by the fundamental symmetric mode (S0) of Lamb wave. This amplitude is also dependent on the length of the fatigue crack as well as the incident wave angle. The experimental and FE results correlate well, so the modelling approach can be implemented for practical design of damage monitoring systems as well as for the evaluation of the severity of the fatigue cracks.

  18. Early genetic evaluation of open-pollinated Douglas-fir families

    Treesearch

    Kurt H. Riitters; David A. Perry

    1987-01-01

    In a test of early genetic evaluation of the growth potential of 14 families of open-pollinated Douglas-fir (Pseudotsuga menziesii) [Mirb.] Franco), measures of growth and phenology of seedligns grown in a coldframe were correlated with height of saplings in evaluation plantations at 9, 12, and 15 years. fifteen-year height was most strongly...

  19. Comparative proteomic study in serum of patients with primary open-angle glaucoma and pseudoexfoliation glaucoma.

    PubMed

    González-Iglesias, Héctor; Álvarez, Lydia; García, Montserrat; Escribano, Julio; Rodríguez-Calvo, Pedro Pablo; Fernández-Vega, Luis; Coca-Prados, Miguel

    2014-02-26

    Alterations in the sera proteins between patients with Primary Open-Angle Glaucoma (POAG), Pseudoexfoliation Glaucoma (PEXG), and healthy controls were identified through a proven approach utilizing equalization of high-abundance serum proteins with ProteoMiner™, two-dimensional fluorescent difference gel electrophoresis (2D-DIGE), MALDI-TOF/TOF, and nanoLC-MS-MS. Quantitative immunoassays of the 17 most-differentially-altered proteins identified in this analysis confirmed that they were also over expressed in the intact serum of newly recruited glaucoma patients. Overall, this report identifies a panel of candidates for glaucoma biomarkers and supports their further validation in large population studies. Additionally, functional pathway analysis of these candidate proteins suggested that they are part of a network linked to regulating immune and inflammatory-related processes. The data have been deposited to the ProteomeXchange with identifier PXD000198. POAG and PEXG are major causes of age-related blindness in the world; however, treatment can be very effective if they are identified early on in the progression. Genetic linkage studies can only explain a limited number of cases, suggesting that these forms of glaucoma are multigenic in nature. Other important factors, such as modifier genes, epigenetic influences, environmental and dietary agents, and inflammatory and oxidative effects are also believed to affect the development of these diseases. The characterization of metabolic and/or proteins changes, for example in bodily fluids, before the clinical manifestation of glaucoma is of considerable relevance for its early diagnosis. In the present work, identification of over-expressed proteins in serum of glaucoma patients (POAG and PEXG) linked to immune and inflammatory processes supports the finding that changes in these pathways also manifest systemically in patients with these pathologies. This study provides a new basis to validate the identified

  20. Differential protein expression in tears of patients with primary open angle and pseudoexfoliative glaucoma.

    PubMed

    Pieragostino, Damiana; Bucci, Sonia; Agnifili, Luca; Fasanella, Vincenzo; D'Aguanno, Simona; Mastropasqua, Alessandra; Ciancaglini, Marco; Mastropasqua, Leonardo; Di Ilio, Carmine; Sacchetta, Paolo; Urbani, Andrea; Del Boccio, Piero

    2012-04-01

    Primary open angle (POAG) and pseudoexfoliative glaucoma (PXG) are the most common primary and secondary forms of glaucoma, respectively. Even though the patho-physiology, aqueous humor composition, risk factors, clinical features, therapy and drug induced ocular surface changes in POAG and PXG have been widely studied, to date information concerning tear protein characterization is lacking. Tears are a source of nourishment for ocular surface tissues and a vehicle to remove local waste products, metabolized drugs and inflammatory mediators produced in several ophthalmic diseases. In glaucoma, the proteomic definition of tears may provide insights concerning patho-physiology of the disease and ocular surface modifications induced by topical therapy. Our study aimed at characterizing protein patterns in tears of patients with medically controlled POAG and PXG. A comparative tears proteomic analysis by label-free LC-MS(E) highlighted differences in the expression of several proteins in the two glaucoma sub-types and control subjects, highlighting inflammation pathways expressed in both diseases. Results were independently reconfirmed by SDS-PAGE and linear MALDI-TOF MS, validating altered levels of Lysozyme C, Lipocalin-1, Protein S100, Immunoglobulins and Prolactin Inducible Protein. Moreover, we found a differential pattern of phosphorylated Cystatin-S that distinguishes the two pathologies. The most relevant results suggest that in both pathologies there may be active inflammation pathways related to the disease and/or induced by therapy. We show, for the first time, tear protein patterns expressed under controlled intraocular pressure conditions in POAG and PXG subjects. These findings could help in the understanding of molecular machinery underlying these ophthalmologic diseases, resulting in early diagnosis and more specific therapy.

  1. Retrospective 25-year follow-up of treatment outcomes in angle Class III patients : Early versus late treatment.

    PubMed

    Wendl, B; Muchitsch, A P; Winsauer, H; Walter, A; Droschl, H; Jakse, N; Wendl, M; Wendl, T

    2017-05-01

    To assess early versus late treatment of Class III syndrome for skeletal and dental differences. Thirty-eight Class III patients treated with a chincup were retrospectively analyzed. Baseline data were obtained by reviewing pretreatment (T0) anamnestic records, cephalograms, and casts. The cases were assigned to an early or a late treatment group based on age at T0 (up to 9 years or older than 9 years but before the pubertal growth spurt). Both groups were further compared based on posttreatment data (T1) and long-term follow-up data collected approximately 25 years after treatment (T2). Early treatment was successful in 74% and late treatment in 67% of cases. More failures were noted among male patients. The late treatment group was characterized post therapeutically by significantly more pronounced skeletal parameters of jaw size relative to normal Class I values; in addition, a greater skeletal discrepancy between maxilla and mandible, higher values for mandibular length, Cond-Pog, ramus height, overjet, anterior posterior dysplasia indicator (APDI), lower anterior face height, and gonial angle were measured at T1. The angle between the AB line and mandibular plane was found to be larger at T0, T1, and T2, as well as more pronounced camouflage positions of the lower anterior teeth at T0. The early treatment group was found to exhibit greater amounts of negative overjet at T0 but more effective correction at T1. Early treatment of Class III syndrome resulted in greater skeletal changes with less dental compensation.

  2. Demonstration of angle widening using EyeCam after laser peripheral iridotomy in eyes with angle closure.

    PubMed

    Perera, Shamira A; Quek, Desmond T; Baskaran, Mani; Tun, Tin A; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2010-06-01

    To evaluate EyeCam in detecting changes in angle configuration after laser peripheral iridotomy (LPI) in comparison to gonioscopy, the reference standard. Prospective comparative study. Twenty-four subjects (24 eyes) with primary angle-closure glaucoma (PACG) were recruited. Gonioscopy and EyeCam (Clarity Medical Systems) imaging of all 4 angle quadrants were performed, before and 2 weeks after LPI. Images were graded according to angle structures visible by an observer masked to clinical data or the status of LPI, and were performed in a random order. Angle closure in a quadrant was defined as the inability to visualize the posterior trabecular meshwork. We determined the number of quadrants with closed angles and the mean number of clock hours of angle closure before and after LPI in comparison to gonioscopy. Using EyeCam, all 24 eyes showed at least 1 quadrant of angle widening after LPI. The mean number of clock hours of angle closure decreased significantly, from 8.15 +/- 3.47 clock hours before LPI to 1.75 +/- 2.27 clock hours after LPI (P < .0001, Wilcoxon signed rank test). Overall, gonioscopy showed 1.0 +/- 1.41 (95% CI, 0.43-1.57) quadrants opening from closed to open after LPI compared to 2.0 +/- 1.28 (95% CI, 1.49-2.51, P = .009) quadrants with EyeCam. Intra-observer reproducibility of grading the extent of angle closure in clock hours in EyeCam images was moderate to good (intraclass correlation coefficient 0.831). EyeCam may be used to document changes in angle configuration after LPI in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  3. HST Multicolor (255-1042 nm) Photometry of Saturn's Main Rings. 1; Radial Profiles, Phase and Opening Angle Variations, and Regional Spectra

    NASA Technical Reports Server (NTRS)

    Cuzzi, Jeffrey N.; French, Richard G.; Dones, Luke; DeVincenzi, Donald (Technical Monitor)

    2001-01-01

    The main rings of Saturn were observed with the Planetary Camera of the WFPC2 instrument on the Hubble Space Telescope (HST) from September 1996 to August 2000 as the'ring opening angle to Earth and Sun increased from 4 deg to 24 deg, with a spread of phase angles between 0.3 deg and 6 deg at each opening angle. The rings were routinely observed in the five HST wideband UBVRI filters (F336W, F439W, F555W, F675W, and F814W) and occasionally in the F255W, F785LP, and F1042M filters. The emphasis in this series of papers will be on radial color (implying compositional) variations. In this first paper we describe the analysis technique and calibration procedure, note revisions in a previously published Voyager ring color data analysis, and present new results based on over 100 HST images. In the 300-600 nm spectral range where the rings are red, the 555nm/336nm ratio increases by about 14% as the phase angle increases from 0.3 deg to 6 deg. This effect, never reported previously for the rings, is significantly larger than the phase reddening which characterizes other icy objects, primarily because of the redness of the rings. However, there is no discernible tendency for color to vary with ring opening angle at a given phase angle, and there is no phase variation of color where the spectrum is flat. We infer from this combination of facts that multiple intraparticle scattering, either in a regolith or between facets of an unusually rough surface, is important in these geometries, but that multiple interparticle scattering in a vertically extended layer is not. Voyager color ratios at a phase angle of 14 deg are compatible with this trend, but calibration uncertainties prevent their use in quantitative modeling. Overall ring-average spectra are compatible with those of earlier work within calibration uncertainties, but ring spectra vary noticeably with region. We refine and subdivide the regions previously defined by others. The variation seen between radial profiles of

  4. Cosmic Ray Energy Determination by the Reduced-Opening Angle Method

    NASA Technical Reports Server (NTRS)

    Gregory, John C.

    1998-01-01

    The reduced opening angle technique offers a simple way with minimal model dependence to measure cosmic ray energies over a broad range with out any normalization uncertainties. The emulsion film and CR39 detectors proposed are well established techniques and should perform adequately. The analysis method depends on accurate automatic scanning of the CR39 plates. UAH have developed such a capability. With the proposed geometry energy measurements to approx. 5 TeV/a can be made. The expected iron event rate (E greater than or equal to 500 GeV/a) is 10/sq m day. The expected energy resolution, from accelerator calibrations at 200 GeV/a, is -50% to +80%. Since the absolute flux has some sensitivity to the assumed power law index it is essential that good energy resolution is obtained. The expected charge resolution is approx. 0.3 charge units for the CNO group falling to approx. 1 charge unit for the iron group. A suitable event trigger would be a measurable (greater than 2 micrometer) deflected heavy (Z greater than 2) fragment. One potential background is electromagnetic dissociation that predominantly couples to individual protons or alphas. Although the cross- sections can be appreciable such events will not pass the event trigger.

  5. Gonioscopy assisted transluminal trabeculotomy: an ab interno circumferential trabeculotomy for the treatment of primary congenital glaucoma and juvenile open angle glaucoma.

    PubMed

    Grover, Davinder S; Smith, Oluwatosin; Fellman, Ronald L; Godfrey, David G; Butler, Michelle R; Montes de Oca, Ildamaris; Feuer, William J

    2015-08-01

    To introduce a novel ab interno 360° trabeculotomy for treating primary congenital glaucoma (PCG) and juvenile open angle glaucoma (JOAG) and report preliminary results. A retrospective chart review of patients who underwent a gonioscopy assisted transluminal trabeculotomy (GATT) procedure by four of the authors (DSG, OS, RLF and DGG) between October 2011 and October 2013. The surgery was performed in patients ≤30 years old with a dysgenic anterior segment angle and uncontrolled PCG and JOAG. Fourteen eyes of 10 patients underwent GATT with follow-up >12 months (12-33 months; mean 20.4). Patients ranged in age from 17 months to 30 years (mean=18.4 years), and five (50%) were female patients. No complications occurred during or following surgery except for early postoperative hyphema in five (36%) of eyes, all cleared by 1 month. The mean intraocular pressure (IOP) decreased from 27.3 to 14.8 mm Hg and the mean number of medications required decreased from 2.6 to 0.86. Five eyes had a drop in IOP ≥15 mm Hg (range 15-39). The preliminary results and safety for GATT, a minimally invasive conjunctival sparing circumferential trabeculotomy, are promising and at least equivalent to previous results for ab externo trabeculotomy for the treatment of PCG and JOAG. All eyes in the study were considered a clinical success. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Fixed combination of bimatoprost and timolol in patients with primary open-angle glaucoma or ocular hypertension with inadequate IOP adjustment

    PubMed Central

    Brief, Gerrett; Lammich, Tobias; Nagel, Edgar; Pfennigsdorf, Sabine; Spraul, Christoph W; Ho, Selwyn

    2010-01-01

    Objective To assess the efficacy and tolerability of a fixed combination of bimatoprost and timolol (BTFC) in a large patient sample in a clinical setting. Methods In this multicenter, observational, noncontrolled, open-label study, patients (n = 1862) with primary open-angle glaucoma or ocular hypertension were treated with BTFC. Assessments were made at baseline, six weeks, and three months. Results Prior to starting BTFC, 92.3% of patients were taking other ocular hypotensive medications. In the overall group at three months, mean intraocular pressure was reduced from baseline (21.7 ± 4.5 mmHg and 21.8 ± 4.9 mmHg for the right and left eye, respectively) to 16.1 ± 3.0 mmHg for each eye (P < 0.0001). The majority of patients (92%) reported no adverse events. The most commonly reported adverse events (in >1% of patients) were eye irritation, and ocular and conjunctival hyperemia. Adherence to treatment was generally better than (35.4%) or the same as (57.5%) with prior therapy. BTFC tolerability was rated as excellent or good by 92.3% of physicians and 85.8% of patients. Conclusions In a large group of patients with primary open-angle glaucoma or ocular hypertension, treatment with BTFC was associated with consistent reductions in IOP, improved adherence to treatment, and good tolerability. PMID:20957059

  7. Baseline Risk Factors that Predict the Development of Open-angle Glaucoma in a Population: The Los Angeles Latino Eye Study

    PubMed Central

    Jiang, Xuejuan; Varma, Rohit; Wu, Shuang; Torres, Mina; Azen, Stanley P; Francis, Brian A.; Chopra, Vikas; Nguyen, Betsy Bao-Thu

    2012-01-01

    Objective To determine which baseline socio-demographic, lifestyle, anthropometric, clinical, and ocular risk factors predict the development of open-angle glaucoma (OAG) in an adult population. Design A population-based, prospective cohort study. Participants A total of 3,772 self-identified Latinos aged 40 years and older from Los Angeles, California who were free of OAG at baseline. Methods Participants from the Los Angeles Latino Eye Study had standardized study visits at baseline and 4-year follow-up with structured interviews and a comprehensive ophthalmologic examination. OAG was defined as the presence of an open angle and a glaucomatous visual field abnormality and/or evidence of glaucomatous optic nerve damage in at least one eye. Multivariate logistic regression with stepwise selection was performed to determine which potential baseline risk factors independently predict the development of OAG. Main Outcome Measure Odds ratios for various risk factors. Results Over the 4-year follow-up, 87 participants developed OAG. The baseline risk factors that predict the development of OAG include: older age (odds ratio [OR] per decade, 2.19; 95% confidence intervals [CI], 1.74-2.75; P<0.001), higher intraocular pressure (OR per mmHg, 1.18; 95% CI, 1.10-1.26; P<0.001), longer axial length (OR per mm, 1.48; 95% CI, 1.22-1.80; P<0.001), thinner central cornea (OR per 40 μm thinner, 1.30; 95% CI, 1.00-1.70; P=0.050) higher waist to hip ratio (OR per 0.05 higher, 1.21; 95% CI, 1.05-1.39; P=0.007) and lack of vision insurance (OR, 2.08; 95% CI, 1.26-3.41; P=0.004). Conclusions Despite a mean baseline IOP of 14 mmHg in Latinos, higher intraocular pressure is an important risk factor for developing OAG. Biometric measures suggestive of less structural support such as longer axial length and thin CCT were identified as important risk factors. Lack of health insurance reduces access to eye care and increases the burden of OAG by reducing the likelihood of early detection

  8. Hong's grading for evaluating anterior chamber angle width.

    PubMed

    Kim, Seok Hwan; Kang, Ja Heon; Park, Ki Ho; Hong, Chul

    2012-11-01

    To compare Hong's grading method with anterior segment optical coherence tomography (AS-OCT), gonioscopy, and the dark-room prone-position test (DRPT) for evaluating anterior chamber width. The anterior chamber angle was graded using Hong's grading method, and Hong's angle width was calculated from the arctangent of Hong's grades. The correlation between Hong's angle width and AS-OCT parameters was analyzed. The area under the receiver operating characteristic curve (AUC) for Hong's grading method when discriminating between narrow and open angles as determined by gonioscopy was calculated. Correlation analysis was performed between Hong's angle width and intraocular pressure (IOP) changes determined by DRPT. A total of 60 subjects were enrolled. Of these subjects, 53.5 % had a narrow angle. Hong's angle width correlated significantly with the AS-OCT parameters (r = 0.562-0.719, P < 0.01). A Bland-Altman plot showed relatively good agreement between Hong's angle width and the angle width obtained by AS-OCT. The ability of Hong's grading method to discriminate between open and narrow angles was good (AUC = 0.868, 95 % CI 0.756-0.942). A significant linear correlation was found between Hong's angle width and IOP change determined by DRPT (r = -0.761, P < 0.01). Hong's grading method is useful for detecting narrow angles. Hong's grading correlated well with AS-OCT parameters and DRPT.

  9. Correlation between Macular Thickness and Visual Field in Early Open Angle Glaucoma: A Cross-Sectional Study.

    PubMed

    Fallahi Motlagh, Behzad; Sadeghi, Ali

    2017-01-01

    The aim of this study was to correlate macular thickness and visual field parameters in early glaucoma. A total of 104 eyes affected with early glaucoma were examined in a cross-sectional, prospective study. Visual field testing using both standard automated perimetry (SAP) and shortwave automated perimetry (SWAP) was performed. Global visual field parameters, including mean deviation (MD) and pattern standard deviation (PSD), were recorded and correlated with spectral domain optical coherence tomography (SD-OCT)-measured macular thickness and asymmetry. Average macular thickness correlated significantly with all measures of visual field including MD-SWAP (r = 0.42), MD-SAP (r = 0.41), PSD-SWAP (r = -0.23), and PSD-SAP (r = -0.21), with P-values <0.001 for all correlations. The mean MD scores (using both SWAP and SAP) were significantly higher in the eyes with thin than in those with intermediate average macular thickness. Intraeye (superior macula thickness - inferior macula thickness) asymmetries correlated significantly with both PSD-SWAP (r = 0.63, P < 0.001) and PSD-SAP (r = 0.26, P = 0.01) scores. This study revealed a significant correlation between macular thickness and visual field parameters in early glaucoma. The results of this study should make macular thickness measurements even more meaningful to glaucoma specialists.

  10. Molecular mechanical studies of DNA flexibility: Coupled backbone torsion angles and base-pair openings

    PubMed Central

    Keepers, Joe W.; Kollman, Peter A.; Weiner, Paul K.; James, Thomas L.

    1982-01-01

    Molecular mechanics studies have been carried out on “B-DNA-like” structures of [d(C-G-C-G-A-A-T-T-C-G-C-G)]2 and [d(A)]12·[d(T)]12. Each of the backbone torsion angles (ψ, φ, ω, ω′, φ′) has been “forced” to alternative values from the normal B-DNA values (g+, t, g-, g-, t conformations). Compensating torsion angle changes preserve most of the base stacking energy in the double helix. In a second part of the study, one purine N3-pyrimidine N1 distance at a time has been forced to a value of 6 Å in an attempt to simulate the base opening motions required to rationalize proton exchange data for DNA. When the 6-Å constraint is removed, many of the structures revert to the normal Watson-Crick hydrogen-bonded structure, but a number are trapped in structures ≈5 kcal/mol higher in energy than the starting B-DNA structure. The relative energy of these structures, some of which involve a non-Watson-Crick thymine C2(carbonyl)[unk]adenine 6NH2 hydrogen bond, are qualitatively consistent with the ΔH for a “base pair-open state” suggested by Mandal et al. of 4-6 kcal/mol [Mandal, C., Kallenbach, N. R. & Englander, S. W. (1979) J. Mol. Biol. 135, 391-411]. The picture of DNA flexibility emerging from this study depicts the backbone as undergoing rapid motion between local torsional minima on a nanosecond time scale. Backbone motion is mainly localized within a dinucleoside segment and generally not conformationally coupled along the chain or across the base pairs. Base motions are much smaller in magnitude than backbone motions. Base sliding allows imino N—H exchange, but it is localized, and only a small fraction of the N—H groups is exposed at any one time. Stacking and hydrogen bonding cause a rigid core of bases in the center of the molecule accounting for the hydrodynamic properties of DNA. PMID:6957879

  11. Latanoprostene Bunod Ophthalmic Solution 0.024%: A Review in Open-Angle Glaucoma and Ocular Hypertension.

    PubMed

    Hoy, Sheridan M

    2018-05-14

    Latanoprostene bunod ophthalmic solution 0.024% (hereafter referred to as latanoprostene bunod 0.024%) [Vyzulta™] is a nitric oxide (NO)-donating prostaglandin F 2α analogue approved in the USA for the reduction of intraocular pressure (IOP) in patients with open-angle glaucoma (OAG) or ocular hypertension. It is thought to lower IOP by increasing aqueous humour outflow through the uveoscleral pathway (mediated by latanoprost acid) and increasing the facility of aqueous humour outflow through the trabecular meshwork pathway (mediated by NO). Results from two multinational, phase III studies (APOLLO and LUNAR) and a pooled analysis of these studies demonstrated the noninferiority of latanoprostene bunod 0.024% to timolol ophthalmic solution 0.5% (hereafter referred to as timolol 0.5%) in terms of IOP-lowering efficacy over 3 months in patients with OAG or ocular hypertension, with the superiority of latanoprostene bunod 0.024% over timolol 0.5% subsequently demonstrated in APOLLO and the pooled analysis. Moreover, there was no apparent loss of IOP-lowering effect in subsequent safety extension periods of up to 9 months. The IOP-lowering efficacy seen in APOLLO and LUNAR was confirmed in a phase III study (JUPITER) in Japanese patients, with IOP reductions observed early (week 4) and maintained over the longer-term (12 months). Latanoprostene bunod 0.024% was well tolerated over up to 12 months in these studies, with most ocular treatment-emergent adverse events (TEAEs) being mild to moderate in severity. Thus, current evidence indicates once-daily latanoprostene bunod 0.024% is an effective and well tolerated treatment option for the reduction of IOP in adults with OAG or ocular hypertension.

  12. Mapping a gene for adult-onset primary open-angle glaucoma to chromosome 3q

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wirtz, M.K.; Samples, J.R.; Kramer, P.L.

    1997-02-01

    Glaucoma is the third-leading cause of blindness in the world, affecting >13.5 million people. Adult-on-set primary open-angle glaucoma (POAG) is the most common form of glaucoma in the United States. We present a family in which adult-onset POAG is inherited as an autosomal dominant trait. Twelve affected family members were identified from 44 at-risk individuals. The disease-causing gene was mapped to chromosome 3q21-24, with analysis of recombinant haplotypes suggesting a total inclusion region of 11.1 cM between markers D3S3637 and D3S1744. This is the first report of mapping of an adult-onset POAG gene to chromosome 3q, gene symbol GLC1C. 57more » refs., 3 figs., 3 tabs.« less

  13. First-line treatment for elevated intraocular pressure (IOP) associated with open-angle glaucoma or ocular hypertension: focus on bimatoprost

    PubMed Central

    Law, Simon K

    2007-01-01

    The goal of treatment for open-angle glaucoma or ocular hypertension is to improve quality of life through reduction of intraocular pressure (IOP) to preserve visual function. Prostaglandins, as a newer class of ocular hypotensive agents, have been shown to be effective in IOP reduction by the primary mechanism of action of increase the uveoscleral outflow. Bimatoprost is a member this class, but different from the other members by having an ethyl amide group rather than an isopropyl ester at the C-1 carbon of the alpha chain. Bimatoprost used once daily has been shown to be more effect in IOP reduction than other classes of topical ocular hypotensive agents including beta-blockers, carbonic anhydrase inhibitors, and alpha agonists. Comparing with other topical prostaglandins, bimatoprost may be slightly more effective in IOP reduction, but the clinical significance is uncertain. The commonly reported adverse events associated with bimatoprost are localized to the eye and include conjunctival hyperemia, changes in the pigmentation of the periocular skin and iris, and eyelash darkening and growth. It is currently approved by the Food and Drug Administration (FDA) and the European Commission (EC) for first-line therapy for the reduction of elevated IOP in patients with open-angle glaucoma or ocular hypertension. PMID:19668476

  14. Mediterranean diet adherence by patients with primary open angle glaucoma.

    PubMed

    Abreu-Reyes, J A; Álvarez-Luis, D; Arteaga-Hernández, V; Sánchez-Mendez, M; Abreu-González, R

    2017-08-01

    To study the adherence to the Mediterranean diet in patients affected by primary open angle glaucoma (POAG). An observational study was conducted to assess the adherence to the Mediterranean diet in patients affected by POAG, and who attended the Ophthalmology Department of the Canary Islands University Hospital. The study included completing a 14-item questionnaire validated by the PREDIMED Study, in person or by telephone. A total of 100 questionnaires were completed successfully by 50 males and 50 females. The mean age was 69.58 years for the males and 67.42 years for women. The men had more comorbidities than women (tobacco 14 vs. 3%), arterial hypertension, and diabetes (30 vs. 28%, and 16 vs. 6%, respectively). Adherence to the Mediterranean diet in males, was low in 9 patients (18%), moderate in 37 (74%), and high in 4 (8%) cases. In women adherence was low in 14 patients (28%), moderate in 34 (68%), and high in 2 (6%) cases. The overall adhesion to the Mediterranean diet is low in 23%, moderate in 71% and high in 6% of the cases. Patients who are affected by POAG have moderate adherence to the Mediterranean diet. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Ocular Biometrics of Myopic Eyes With Narrow Angles.

    PubMed

    Chong, Gabriel T; Wen, Joanne C; Su, Daniel Hsien-Wen; Stinnett, Sandra; Asrani, Sanjay

    2016-02-01

    The purpose of this study was to compare the ocular biometrics between myopic patients with and without narrow angles. Patients with a stable myopic refraction (myopia worse than -1.00 D spherical equivalent) were prospectively recruited. Angle status was assessed using gonioscopy and biometric measurements were performed using an anterior segment optical coherence tomography and an IOLMaster. A total of 29 patients (58 eyes) were enrolled with 13 patients (26 eyes) classified as having narrow angles and 16 patients (32 eyes) classified as having open angles. Baseline demographics of age, sex, and ethnicity did not differ significantly between the 2 groups. The patients with narrow angles were on average older than those with open angles but the difference did not reach statistical significance (P=0.12). The central anterior chamber depth was significantly less in the eyes with narrow angles (P=0.05). However, the average lens thickness, although greater in the eyes with narrow angles, did not reach statistical significance (P=0.10). Refractive error, axial lengths, and iris thicknesses did not differ significantly between the 2 groups (P=0.32, 0.47, 0.15). Narrow angles can occur in myopic eyes. Routine gonioscopy is therefore recommended for all patients regardless of refractive error.

  16. Corneal indentation in the early management of acute angle closure.

    PubMed

    Masselos, Katherine; Bank, Allan; Francis, Ian C; Stapleton, Fiona

    2009-01-01

    To describe in detail corneal indentation (CI) in the management of a series of patients treated for acute angle closure (AAC). Retrospective, consecutive, noncomparative case series. Seven consecutive patients (8 eyes) referred to the authors with the diagnosis of AAC. Patients presented to the Prince of Wales Hospital, Randwick, or to the private practices of the authors. Seven patients (8 eyes) underwent CI as part of their early management for AAC. Reduction in intraocular pressure (IOP), symptoms of AAC and pain relief. Of the 7 patients, complete data were available for 6. The IOP was significantly reduced (P<0.05) and 3 of 4 patients with severe acute pain reported early resolution of pain after CI. The average reduction in IOP was 20.9 mmHg (range +1 to -45). All patients subsequently underwent definitive management with laser peripheral iridotomies or lensectomy using phacoemulsification. Three patients treated acutely with CI without any medical agents had a mean IOP reduction of 21 mmHg (range, 20-23) after indentation. Corneal indentation is a rapid, portable, and effective method of reducing elevated IOP in the setting of AAC. It can be performed with instrumentation that is readily at hand and allows for rapid pain relief. This reduction in IOP improves corneal clarity and permits further definitive management of the patient with AAC. The authors have no proprietary or commercial interest in any materials discussed in this article.

  17. Longitudinal changes of angle configuration in primary angle-closure suspects: the Zhongshan Angle-Closure Prevention Trial.

    PubMed

    Jiang, Yuzhen; Chang, Dolly S; Zhu, Haogang; Khawaja, Anthony P; Aung, Tin; Huang, Shengsong; Chen, Qianyun; Munoz, Beatriz; Grossi, Carlota M; He, Mingguang; Friedman, David S; Foster, Paul J

    2014-09-01

    To determine longitudinal changes in angle configuration in the eyes of primary angle-closure suspects (PACS) treated by laser peripheral iridotomy (LPI) and in untreated fellow eyes. Longitudinal cohort study. Primary angle-closure suspects aged 50 to 70 years were enrolled in a randomized, controlled clinical trial. Each participant was treated by LPI in 1 randomly selected eye, with the fellow eye serving as a control. Angle width was assessed in a masked fashion using gonioscopy and anterior segment optical coherence tomography (AS-OCT) before and at 2 weeks, 6 months, and 18 months after LPI. Angle width in degrees was calculated from Shaffer grades assessed under static gonioscopy. Angle configuration was also evaluated using angle opening distance (AOD250, AOD500, AOD750), trabecular-iris space area (TISA500, TISA750), and angle recess area (ARA) measured in AS-OCT images. No significant difference was found in baseline measures of angle configuration between treated and untreated eyes. At 2 weeks after LPI, the drainage angle on gonioscopy widened from a mean of 13.5° at baseline to a mean of 25.7° in treated eyes, which was also confirmed by significant increases in all AS-OCT angle width measures (P<0.001 for all variables). Between 2 weeks and 18 months after LPI, a significant decrease in angle width was observed over time in treated eyes (P<0.001 for all variables), although the change over the first 5.5 months was not statistically significant for angle width measured under gonioscopy (P = 0.18), AOD250 (P = 0.167) and ARA (P = 0.83). In untreated eyes, angle width consistently decreased across all follow-up visits after LPI, with a more rapid longitudinal decrease compared with treated eyes (P values for all variables ≤0.003). The annual rate of change in angle width was equivalent to 1.2°/year (95% confidence interval [CI], 0.8-1.6) in treated eyes and 1.6°/year (95% CI, 1.3-2.0) in untreated eyes (P<0.001). Angle width of treated eyes

  18. Preservative-free versus preserved latanoprost eye drops in patients with open-angle glaucoma or ocular hypertension.

    PubMed

    Aptel, Florent; Choudhry, Reena; Stalmans, Ingeborg

    2016-08-01

    This study compared the efficacy, safety, and pharmacokinetics of a preservative-free latanoprost formulation to an established, benzalkonium chloride (BAK) containing formulation for the treatment of open-angle glaucoma or ocular hypertension. This was a phase II, randomized, cross-over, investigator-masked, multi-center, pilot study (NCT01494753). A total of 30 untreated adult patients (aged ≥18 years) with primary open angle glaucoma, pseudo-exfoliative glaucoma, pigmentary glaucoma, or ocular hypertension received either preservative-free or preserved latanoprost once daily in both eyes for 6 weeks, before crossing over to receive the other treatment. Efficacy (intraocular pressure [IOP] at 8 am, midday, 4 pm and 8 pm, and global efficacy assessment by investigator), safety (adverse events, ocular symptoms and global tolerance, slit lamp examination, funduscopy, visual field examination, visual acuity, and heart rate), and pharmacokinetics were assessed at Days 0, 42, and 84. Both treatments resulted in a reduction in IOP that was similar for the preservative-free and the preserved formulation at all time points. Similarly, the overall diurnal reduction was similar in both groups (6.3 mmHg [27.9% reduction] and 6.4 mmHg [28.1% reduction] for preserved and preservative-free latanoprost, respectively). There were no differences in global efficacy assessment or in the safety and tolerance of each treatment. Systemic concentrations of latanoprost were very low; AUC0-30 and Cmax were lower and tmax was longer for preservative-free latanoprost. Preservative-free latanoprost showed similar efficacy at all time points compared to BAK preservative containing formulation, with no difference in tolerance, allowing progression to phase III clinical development.

  19. Minimally Invasive and Open Distal Chevron Osteotomy for Mild to Moderate Hallux Valgus.

    PubMed

    Brogan, Kit; Lindisfarne, Edward; Akehurst, Harold; Farook, Usama; Shrier, Will; Palmer, Simon

    2016-11-01

    Minimally invasive surgical (MIS) techniques are increasingly being used in foot and ankle surgery but it is important that they are adopted only once they have been shown to be equivalent or superior to open techniques. We believe that the main advantages of MIS are found in the early postoperative period, but in order to adopt it as a technique longer-term studies are required. The aim of this study was to compare the 2-year outcomes of a third-generation MIS distal chevron osteotomy with a comparable traditional open distal chevron osteotomy for mild-moderate hallux valgus. Our null hypothesis was that the 2 techniques would yield equivalent clinical and radiographic results at 2 years. This was a retrospective cohort study. Eighty-one consecutive feet (49 MIS and 32 open distal chevron osteotomies) were followed up for a minimum 24 months (range 24-58). All patients were clinically assessed using the Manchester-Oxford Foot Questionnaire. Radiographic measures included hallux valgus angle, the intermetatarsal angle, hallux interphalangeal angle, metatarsal phalangeal joint angle, distal metatarsal articular angle, tibial sesamoid position, shape of the first metatarsal head, and plantar offset. Statistical analysis was done using Student t test or Wilcoxon rank-sum test for continuous data and Pearson chi-square test for categorical data. Clinical and radiologic postoperative scores in all domains were substantially improved in both groups (P < .001), but there was no statistically significant difference in improvement of any domain between open and MIS groups (P > .05). There were no significant differences in complications between the 2 groups ( > .5). The midterm results of this third-generation technique show that it was a safe procedure with good clinical outcomes and comparable to traditional open techniques for symptomatic mild-moderate hallux valgus. Level III, retrospective comparative study. © The Author(s) 2016.

  20. A New Approach to Micro-arcsecond Astrometry with SIM Allowing Early Mission Narrow Angle Measurements of Compelling Astronomical Targets

    NASA Technical Reports Server (NTRS)

    Shaklan, Stuart; Pan, Xiaopei

    2004-01-01

    The Space Interferometry Mission (SIM) is capable of detecting and measuring the mass of terrestrial planets around stars other than our own. It can measure the mass of black holes and the visual orbits of radio and x-ray binary sources. SIM makes possible a new level of understanding of complex astrophysical processes. SIM achieves its high precision in the so-called narrow-angle regime. This is defined by a 1 degree diameter field in which the position of a target star is measured with respect to a set of reference stars. The observation is performed in two parts: first, SIM observes a grid of stars that spans the full sky. After a few years, repeated observations of the grid allow one to determine the orientation of the interferometer baseline. Second, throughout the mission, SIM periodically observes in the narrow-angle mode. Every narrow-angle observation is linked to the grid to determine the precise attitude and length of the baseline. The narrow angle process demands patience. It is not until five years after launch that SIM achieves its ultimate accuracy of 1 microarcsecond. The accuracy is degraded by a factor of approx. 2 at mid-mission. Our work proposes a technique for narrow angle astrometry that does not rely on the measurement of grid stars. This technique, called Gridless Narrow Angle Astrometry (GNAA) can obtain microarcsecond accuracy and can detect extra-solar planets and other exciting objects with a few days of observation. It can be applied as early as during the first six months of in-orbit calibration (IOC). The motivations for doing this are strong. First, and obviously, it is an insurance policy against a catastrophic mid-mission failure. Second, at the start of the mission, with several space-based interferometers in the planning or implementation phase, NASA will be eager to capture the public's imagination with interferometric science. Third, early results and a technique that can duplicate those results throughout the mission will

  1. Evaluation of the anterior chamber angle in Asian Indian eyes by ultrasound biomicroscopy and gonioscopy.

    PubMed

    Kaushik, Sushmita; Jain, Rajeev; Pandav, Surinder Singh; Gupta, Amod

    2006-09-01

    To compare the ultrasound biomicroscopic measurement of the anterior chamber angle in Asian Indian eyes, with the angle width estimated by gonioscopy. Patients with open and closed angles attending a glaucoma clinic were recruited for the study. Temporal quadrants of the angles of patients were categorized by gonioscopy as Grade 0 to Grade 4, using Shaffer's classification. These angles were quantified by ultrasound biomicroscopy (UBM) using the following biometric characteristics: Angle opening distance at 250 micro (AOD 250) and 500 micro (AOD 500) from the scleral spur and trabecular meshwork-ciliary process distance (TCPD). The angles were further segregated as "narrow angles" (Schaffer's Grade 2 or less) and "open angles" (Schaffer's Grade 3 and 4). The UBM measurements were computed in each case and analyzed in relation to the gonioscopic angle evaluation. One hundred and sixty three eyes of 163 patients were analyzed. One hundred and six eyes had "narrow angles" and 57 eyes had "open angles" on gonioscopy. There was a significant difference among the mean UBM measurements of each angle grade estimated by gonioscopy (P < 0.001). The Pearson correlation coefficient between all UBM parameters and gonioscopy grades was significant at the 0.01 level. The mean AOD 250, AOD 500 and TCPD in narrow angles were 58+/-49 micro, 102+/-84 micro and 653+/-124 respectively, while it was 176+/-47 micro, 291+/-62 micro and 883+/-94 micro in eyes with open angles (P < 0.001) respectively. The angle width estimated by gonioscopy correlated significantly with the angle dimensions measured by UBM. Gonioscopy, though a subjective test, is a reliable method for estimation of the angle width.

  2. A common variant near TGFBR3 is associated with primary open angle glaucoma.

    PubMed

    Li, Zheng; Allingham, R Rand; Nakano, Masakazu; Jia, Liyun; Chen, Yuhong; Ikeda, Yoko; Mani, Baskaran; Chen, Li-Jia; Kee, Changwon; Garway-Heath, David F; Sripriya, Sarangapani; Fuse, Nobuo; Abu-Amero, Khaled K; Huang, Chukai; Namburi, Prasanthi; Burdon, Kathryn; Perera, Shamira A; Gharahkhani, Puya; Lin, Ying; Ueno, Morio; Ozaki, Mineo; Mizoguchi, Takanori; Krishnadas, Subbiah Ramasamy; Osman, Essam A; Lee, Mei Chin; Chan, Anita S Y; Tajudin, Liza-Sharmini A; Do, Tan; Goncalves, Aurelien; Reynier, Pascal; Zhang, Hong; Bourne, Rupert; Goh, David; Broadway, David; Husain, Rahat; Negi, Anil K; Su, Daniel H; Ho, Ching-Lin; Blanco, Augusto Azuara; Leung, Christopher K S; Wong, Tina T; Yakub, Azhany; Liu, Yutao; Nongpiur, Monisha E; Han, Jong Chul; Hon, Do Nhu; Shantha, Balekudaru; Zhao, Bowen; Sang, Jinghong; Zhang, NiHong; Sato, Ryuichi; Yoshii, Kengo; Panda-Jonas, Songhomita; Ashley Koch, Allison E; Herndon, Leon W; Moroi, Sayoko E; Challa, Pratap; Foo, Jia Nee; Bei, Jin-Xin; Zeng, Yi-Xin; Simmons, Cameron P; Bich Chau, Tran Nguyen; Sharmila, Philomenadin Ferdinamarie; Chew, Merwyn; Lim, Blanche; Tam, Pansy O S; Chua, Elaine; Ng, Xiao Yu; Yong, Victor H K; Chong, Yaan Fun; Meah, Wee Yang; Vijayan, Saravanan; Seongsoo, Sohn; Xu, Wang; Teo, Yik Ying; Cooke Bailey, Jessica N; Kang, Jae H; Haines, Jonathan L; Cheng, Ching Yu; Saw, Seang-Mei; Tai, E-Shyong; Richards, Julia E; Ritch, Robert; Gaasterland, Douglas E; Pasquale, Louis R; Liu, Jianjun; Jonas, Jost B; Milea, Dan; George, Ronnie; Al-Obeidan, Saleh A; Mori, Kazuhiko; Macgregor, Stuart; Hewitt, Alex W; Girkin, Christopher A; Zhang, Mingzhi; Sundaresan, Periasamy; Vijaya, Lingam; Mackey, David A; Wong, Tien Yin; Craig, Jamie E; Sun, Xinghuai; Kinoshita, Shigeru; Wiggs, Janey L; Khor, Chiea-Chuen; Yang, Zhenglin; Pang, Chi Pui; Wang, Ningli; Hauser, Michael A; Tashiro, Kei; Aung, Tin; Vithana, Eranga N

    2015-07-01

    Primary open angle glaucoma (POAG), a major cause of blindness worldwide, is a complex disease with a significant genetic contribution. We performed Exome Array (Illumina) analysis on 3504 POAG cases and 9746 controls with replication of the most significant findings in 9173 POAG cases and 26 780 controls across 18 collections of Asian, African and European descent. Apart from confirming strong evidence of association at CDKN2B-AS1 (rs2157719 [G], odds ratio [OR] = 0.71, P = 2.81 × 10(-33)), we observed one SNP showing significant association to POAG (CDC7-TGFBR3 rs1192415, ORG-allele = 1.13, Pmeta = 1.60 × 10(-8)). This particular SNP has previously been shown to be strongly associated with optic disc area and vertical cup-to-disc ratio, which are regarded as glaucoma-related quantitative traits. Our study now extends this by directly implicating it in POAG disease pathogenesis. © The Author 2015. Published by Oxford University Press.

  3. A common variant near TGFBR3 is associated with primary open angle glaucoma

    PubMed Central

    Li, Zheng; Allingham, R. Rand; Nakano, Masakazu; Jia, Liyun; Chen, Yuhong; Ikeda, Yoko; Mani, Baskaran; Chen, Li-Jia; Kee, Changwon; Garway-Heath, David F.; Sripriya, Sarangapani; Fuse, Nobuo; Abu-Amero, Khaled K.; Huang, Chukai; Namburi, Prasanthi; Burdon, Kathryn; Perera, Shamira A.; Gharahkhani, Puya; Lin, Ying; Ueno, Morio; Ozaki, Mineo; Mizoguchi, Takanori; Krishnadas, Subbiah Ramasamy; Osman, Essam A.; Lee, Mei Chin; Chan, Anita S.Y.; Tajudin, Liza-Sharmini A.; Do, Tan; Goncalves, Aurelien; Reynier, Pascal; Zhang, Hong; Bourne, Rupert; Goh, David; Broadway, David; Husain, Rahat; Negi, Anil K.; Su, Daniel H; Ho, Ching-Lin; Blanco, Augusto Azuara; Leung, Christopher K.S.; Wong, Tina T.; Yakub, Azhany; Liu, Yutao; Nongpiur, Monisha E.; Han, Jong Chul; Hon, Do Nhu; Shantha, Balekudaru; Zhao, Bowen; Sang, Jinghong; Zhang, NiHong; Sato, Ryuichi; Yoshii, Kengo; Panda-Jonas, Songhomita; Ashley Koch, Allison E.; Herndon, Leon W.; Moroi, Sayoko E.; Challa, Pratap; Foo, Jia Nee; Bei, Jin-Xin; Zeng, Yi-Xin; Simmons, Cameron P.; Bich Chau, Tran Nguyen; Sharmila, Philomenadin Ferdinamarie; Chew, Merwyn; Lim, Blanche; Tam, Pansy O.S.; Chua, Elaine; Ng, Xiao Yu; Yong, Victor H.K.; Chong, Yaan Fun; Meah, Wee Yang; Vijayan, Saravanan; Seongsoo, Sohn; Xu, Wang; Teo, Yik Ying; Cooke Bailey, Jessica N.; Kang, Jae H.; Haines, Jonathan L.; Cheng, Ching Yu; Saw, Seang-Mei; Tai, E-Shyong; Richards, Julia E.; Ritch, Robert; Gaasterland, Douglas E.; Pasquale, Louis R.; Liu, Jianjun; Jonas, Jost B.; Milea, Dan; George, Ronnie; Al-Obeidan, Saleh A.; Mori, Kazuhiko; Macgregor, Stuart; Hewitt, Alex W.; Girkin, Christopher A.; Zhang, Mingzhi; Sundaresan, Periasamy; Vijaya, Lingam; Mackey, David A.; Wong, Tien Yin; Craig, Jamie E.; Sun, Xinghuai; Kinoshita, Shigeru; Wiggs, Janey L.; Khor, Chiea-Chuen; Yang, Zhenglin; Pang, Chi Pui; Wang, Ningli; Hauser, Michael A.; Tashiro, Kei; Aung, Tin; Vithana, Eranga N.

    2015-01-01

    Primary open angle glaucoma (POAG), a major cause of blindness worldwide, is a complex disease with a significant genetic contribution. We performed Exome Array (Illumina) analysis on 3504 POAG cases and 9746 controls with replication of the most significant findings in 9173 POAG cases and 26 780 controls across 18 collections of Asian, African and European descent. Apart from confirming strong evidence of association at CDKN2B-AS1 (rs2157719 [G], odds ratio [OR] = 0.71, P = 2.81 × 10−33), we observed one SNP showing significant association to POAG (CDC7–TGFBR3 rs1192415, ORG-allele = 1.13, Pmeta = 1.60 × 10−8). This particular SNP has previously been shown to be strongly associated with optic disc area and vertical cup-to-disc ratio, which are regarded as glaucoma-related quantitative traits. Our study now extends this by directly implicating it in POAG disease pathogenesis. PMID:25861811

  4. Diagnostic ability of peripapillary vessel density measurements of optical coherence tomography angiography in primary open-angle and angle-closure glaucoma.

    PubMed

    Rao, Harsha L; Kadambi, Sujatha V; Weinreb, Robert N; Puttaiah, Narendra K; Pradhan, Zia S; Rao, Dhanaraj A S; Kumar, Rajesh S; Webers, Carroll A B; Shetty, Rohit

    2017-08-01

    To evaluate the diagnostic ability of peripapillary vessel density measurements on optical coherence tomography angiography (OCTA) in primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG), and to compare these with peripapillary retinal nerve fibre layer (RNFL) thickness measurements. In a cross-sectional study, 48 eyes of 33 healthy control subjects, 63 eyes of 39 patients with POAG and 49 eyes of 32 patients with PACG underwent OCTA (RTVue-XR, Optovue, Fremont, California, USA) and RNFL imaging with spectral domain OCT. Diagnostic abilities of vessel density and RNFL parameters were evaluated using area under receiver operating characteristic curves (AUC) and sensitivities at fixed specificities. AUCs of peripapillary vessel density ranged between 0.48 for the temporal sector and 0.88 for the inferotemporal sector in POAG. The same in PACG ranged between 0.57 and 0.86. Sensitivities at 95% specificity ranged from 13% to 70% in POAG, and from 10% to 67% in PACG. AUCs of peripapillary RNFL thickness ranged between 0.51 for the temporal sector and 0.91 for the inferonasal sector in POAG. The same in PACG ranged between 0.61 and 0.87. Sensitivities at 95% specificity ranged from 8% to 68% in POAG, and from 2% to 67% in PACG. AUCs of all peripapillary vessel density measurements were comparable (p>0.05) to the corresponding RNFL thickness measurements in both POAG and PACG. Diagnostic ability of peripapillary vessel density parameters of OCTA, especially the inferotemporal sector measurement, was good in POAG and PACG. Diagnostic abilities of vessel density measurements were comparable to RNFL measurements in both POAG and PACG. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  5. Early Extubation in the Operating Room after Congenital Open-Heart Surgery.

    PubMed

    Fukunishi, Takuma; Oka, Norihiko; Yoshii, Takeshi; Kobayashi, Kensuke; Inoue, Nobuyuki; Horai, Tetsuya; Kitamura, Tadashi; Okamoto, Hirotsugu; Miyaji, Kagami

    2018-01-27

    Early extubation in the operating room after congenital open-heart surgery is feasible, but extubation in the intensive care unit after the operation remains common practice at many institutions. The purpose of this study was to evaluate retrospectively the adequacy of our early-extubation strategy and exclusion criteria through analysis based on the Risk Adjustment in Congenital Heart Surgery method (RACHS-1).This retrospective analysis included 359 cases requiring cardiopulmonary bypass (male, 195; female, 164; weight > 3.0 kg; aged 1 month to 18 years). Neonates and preoperatively intubated patients were excluded. Other exclusion criteria included severe preoperative pulmonary hypertension, high-dose catecholamine requirement after cardiopulmonary bypass, delayed sternal closure, laryngomalacia, serious bleeding, and delayed awakening. The early-extubation rates were compared between age groups and RACHS-1 classes.Overall, 83% of cases (298/359) were extubated in the operating room, classified by RACHS-1 categories as follows: 1, 59/59 (100%); 2, 164/200 (84%); 3, 61/78 (78%); and 4-6, 10/22 (45%). The early extubation rate in categories 1-3 (86%, 288/337) was significantly higher than for categories 4-6 (45.5%, 10/22) (P < 0.001). Because they met one of the exclusion criteria, 61 patients (17%) were not extubated in the operating room. Eight patients (2.7%) required re-intubation after early extubation in the operating room, and longer operation time was significantly associated with re-intubation (P < 0.001).Extubation in the operating room after congenital open-heart surgery was feasible based on our criteria, especially for patients in the low RACHS-1 categories, and involves a very low rate of re-intubation.

  6. Infant titi monkey behavior in the open field test and the effect of early adversity

    PubMed Central

    Larke, Rebecca H.; Toubiana, Alice; Lindsay, Katrina A.; Mendoza, Sally P.; Bales, Karen L.

    2017-01-01

    The open field test is commonly used to measure anxiety-related behavior and exploration in rodents. Here, we used it as a standardized novel environment in which to evaluate the behavioral response of infant titi monkeys (Callicebus cupreus), to determine the effect of presence of individual family members, and to assess how adverse early experience alters infant behavior. Infants were tested in the open field for 5 days at ages 4 and 6 months in four successive 5 min trials on each day. A transport cage, which was situated on one side of the open field, was either empty (non-social control) or contained the father, mother, or sibling. Infant locomotor, vocalization, and exploratory behavior were quantified. Results indicated that age, sex, social condition, and early experience all had significant effects on infant behavior. Specifically, infants were generally more exploratory at 6 months and male infants were more exploratory than females. Infants distinguished between social and non-social conditions but made few behavioral distinctions between the attachment figure and other individuals. Infants which had adverse early life experience demonstrated greater emotional and physical independence, suggesting that early adversity led to resiliency in the novel environment. PMID:28605039

  7. A comparison of latanoprost monotherapy with a combination therapy of timolol/dorzolamide in patients with primary open-angle glaucoma.

    PubMed

    Caça, Ihsan; Simsek, Hüseyin; Unlü, Kaan; Ari, Seyhmus; Keklikçi, Ugur

    2006-01-01

    We compared latanoprost monotherapy therapy with timolol/ dorzolamide in patients with primary open-angle glaucoma to evaluate the effects on intraocular pressure (IOP) and occurrence of adverse events. IOP and topical side effects were evaluated at the beginning, first, and third months. Mean IOP was decreased at the third month. The most common side effect was hyperemia (43.6%). We concluded that latanoprost reduces IOP better than fixed combination and its topical side effects are tolerable.

  8. Geometry and evolution of low-angle normal faults (LANF) within a Cenozoic high-angle rift system, Thailand: Implications for sedimentology and the mechanisms of LANF development

    NASA Astrophysics Data System (ADS)

    Morley, Chris K.

    2009-10-01

    At least eight examples of large (5-35 km heave), low-angle normal faults (LANFs, 20°-30° dip) occur in the Cenozoic rift basins of Thailand and laterally pass into high-angle extensional fault systems. Three large-displacement LANFs are found in late Oligocene-Miocene onshore rift basins (Suphan Buri, Phitsanulok, and Chiang Mai basins), they have (1) developed contemporaneous with, or after the onset of, high-angle extension, (2) acted as paths for magma and associated fluids, and (3) impacted sedimentation patterns. Displacement on low-angle faults appears to be episodic, marked by onset of lacustrine conditions followed by axial progradation of deltaic systems that infilled the lakes during periods of low or no displacement. The Chiang Mai LANF is a low-angle (15°-25°), high-displacement (15-35 km heave), ESE dipping LANF immediately east of the late early Miocene Doi Inthanon and Doi Suthep metamorphic core complexes. Early Cenozoic transpressional crustal thickening followed by the northward motion of India coupled with Burma relative to east Burma and Thailand (˜40-30 Ma) caused migmatization and gneiss dome uplift in the late Oligocene of the core complex region, followed by LANF activity. LANF displacement lasted 4-6 Ma during the early Miocene and possibly transported a late Oligocene-early Miocene high-angle rift system 35 km east. Other LANFs in Thailand have lower displacements and no associated metamorphic core complexes. The three LANFs were initiated as low-angle faults, not by isostatic rotation of high-angle faults. The low-angle dips appear to follow preexisting low-angle fabrics (thrusts, shear zones, and other low-angle ductile foliations) predominantly developed during Late Paleozoic and early Paleogene episodes of thrusting and folding.

  9. Changes in the retrobulbar arterial circulation after decrease of the elevated intraocular pressure in men and women with primary open angle glaucoma.

    PubMed

    Marjanović, Ivan; Martinez, Antonio; Marjanović, Marija; Kontić, Djordje; Hentova-Senćanić, Paraskeva; Marković, Vujica; Bozić, Marija

    2013-01-01

    An altered perfusion of the optic nerve head has been proposed as a pathogenic factor of glaucoma. The aim of this study was to evaluate the changes of the hemodynamic parameters in the retrobulbar arterial circulation after decrease of the elevated intraocular pressure (IOP) in women and men with primary open angle glaucoma. The study included 60 patients (33 males and 27 females) older than 50 years, with diagnosed and treated primary open angle glaucoma (77 eyes of 39 patients had increased IOP, > 25 mm Hg).They were examined at the Clinic of Eye Diseases (complete ophthalmologic exam) and Clinic of Neurology, Clinical Center of Serbia, Belgrade, from December 2009 to December 2010. Imaging of hemodynamic parameters of three retrobulbar arterial vessels: ophthalmic, central retinal and posterior ciliary arteries with color Doppler was performed. Among women, hemodynamic arterial parameter of the peak-systolic velocity was increased in the central retinal artery and decreased in the ophthalmic artery and posterior ciliary arteries; end-diastolic velocity was increased in all three retrobulbar vascular levels; Pourcelot resistivity index was increased, but pulsatility index was decreased in all three vessels. Among men, peak-systolic velocity, end-diastolic velocity and pulsatility index were decreased in all three vessels; resistivity index was increased in the ophthalmic artery, but decreased in the central retinal artery and posterior ciliary arteries. There was a significant change of the ophthalmic artery pulsatility index in women, and the end-diastolic velocity of the ophthalmic artery in men. There was a difference of the retrobulbar arterial circulation between women and men with primary open angle glaucoma after decrease of the elevated intraocular pressure.The role of vascular factors in the supply of the optic disc neuroretinal rim is important.

  10. Ocular characteristics associated with the location of focal lamina cribrosa defects in open-angle glaucoma patients.

    PubMed

    Park, H-Yl; Hwang, Y S; Park, C K

    2017-04-01

    PurposeTo investigate the clinical characteristics according to the location of focal lamina cribrosa (LC) defects and its associated ocular features.Patients and methodsA total of 139 open-angle glaucoma patients underwent Spectralis optical coherence tomography (OCT) with enhanced depth imaging. Alterations in the contour of the LC were investigated to find focal LC defects. The location of the visible LC defect from the neural canal wall (far-peripheral and mid-peripheral) and clock-hour position (superotemporal, temporal and inferotemporal) were classified. Disc ovality ratio and disc-foveal angle were measured from disc and retinal nerve fiber layer (RNFL) photographs. The disc tilt degree was measured using a Heidelberg Retina Tomograph (HRT) III system. The en face OCT image of the disc scans was registered to the disc and RNFL photographs, to determine whether the focal LC defects corresponded spatially to the glaucomatous damage location.ResultsEyes with far-peripheral LC defects were significantly myopic and had a higher disc ovality ratio. The disc tilt degree obtained by HRT revealed significant temporal disc tilt in eyes with temporal LC defects (P<0.001). Eyes with inferotemporal LC defects had a significantly larger disc-foveal angle (P=0.027). The inferotemporal LC defects corresponded to the location of glaucomatous damage in 81.6%; however, only 46.2% of eyes with a superotemporal LC defect and 3.2% of eyes with a temporal LC defect corresponded spatially with the glaucomatous damage location.ConclusionsThe clinical characteristics and association with glaucomatous damage location were different according to the location of focal LC defect.

  11. Longitudinal Changes of Angle Configuration in Primary Angle-Closure Suspects

    PubMed Central

    Jiang, Yuzhen; Chang, Dolly S.; Zhu, Haogang; Khawaja, Anthony P.; Aung, Tin; Huang, Shengsong; Chen, Qianyun; Munoz, Beatriz; Grossi, Carlota M.

    2015-01-01

    Objective To determine longitudinal changes in angle configuration in the eyes of primary angle-closure suspects (PACS) treated by laser peripheral iridotomy (LPI) and in untreated fellow eyes. Design Longitudinal cohort study. Participants Primary angle-closure suspects aged 50 to 70 years were enrolled in a randomized, controlled clinical trial. Methods Each participant was treated by LPI in 1 randomly selected eye, with the fellow eye serving as a control. Angle width was assessed in a masked fashion using gonioscopy and anterior segment optical coherence tomography (AS-OCT) before and at 2 weeks, 6 months, and 18 months after LPI. Main Outcome Measures Angle width in degrees was calculated from Shaffer grades assessed under static gonioscopy. Angle configuration was also evaluated using angle opening distance (AOD250, AOD500, AOD750), trabecular-iris space area (TISA500, TISA750), and angle recess area (ARA) measured in AS-OCT images. Results No significant difference was found in baseline measures of angle configuration between treated and untreated eyes. At 2 weeks after LPI, the drainage angle on gonioscopy widened from a mean of 13.5° at baseline to a mean of 25.7° in treated eyes, which was also confirmed by significant increases in all AS-OCT angle width measures (P<0.001 for all variables). Between 2 weeks and 18 months after LPI, a significant decrease in angle width was observed over time in treated eyes (P<0.001 for all variables), although the change over the first 5.5 months was not statistically significant for angle width measured under gonioscopy (P = 0.18), AOD250 (P = 0.167) and ARA (P = 0.83). In untreated eyes, angle width consistently decreased across all follow-up visits after LPI, with a more rapid longitudinal decrease compared with treated eyes (P values for all variables ≤0.003). The annual rate of change in angle width was equivalent to 1.2°/year (95% confidence interval [CI], 0.8–1.6) in treated eyes and 1.6°/year (95% CI, 1

  12. Intravitreal ranibizumab as an adjunct for Ahmed valve surgery in open-angle glaucoma: a pilot study.

    PubMed

    Desai, Rajen U; Singh, Kuldev; Lin, Shan C

    2013-03-01

    To determine the safety and efficacy of intravitreal ranibizumab therapy before and after Ahmed tube insertion for open-angle glaucoma as a means of optimizing postoperative intraocular pressure control. Randomized, controlled trial. Open-angle glaucoma patients scheduled for Ahmed tube insertion, randomized to ranibizumab or control groups. Ranibizumab (0.5 mg in 0.05 mL) was administered intravitreally at three time points: 9 days prior to surgery, 1 month post-surgery and 2 months post-surgery. Control patients underwent the same procedure without ranibizumab. Success at 6 months postoperatively was defined as intraocular pressure <18 mmHg with no adjunctive medications or intraocular pressure <15 mmHg with one adjunctive medication. The study and control arms included six and five subjects, respectively, with four in each arm undergoing combined cataract surgery. In the ranibizumab arm, the preoperative and postoperative intraocular pressure/medication usage was 21.0 ± 6.7 mmHg on 3.2 ± 1.5 medications and 14.7 ± 1.9 mmHg on 0.5 ± 0.8 medications, respectively. In the control arm, preoperative and postoperative intraocular pressure/medication usage was 18.8 ± 3.8 mmHg on 2.8 ± 1.3 medications and 16.2 ± 3.6 mmHg with 1.8 ± 1.6 medications, respectively. Success was achieved in 83% of subjects in the ranibizumab group compared with 40% in the control group (two-tailed Fisher's exact test, P = 0.24). The findings from this small pilot comparative study suggest that intravitreal ranibizumab use may be a safe and potentially effective adjunctive treatment modality in improving success after Ahmed tube placement. © 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

  13. Microvascular endothelial function and severity of primary open angle glaucoma.

    PubMed

    Bukhari, S M I; Kiu, K Y; Thambiraja, R; Sulong, S; Rasool, A H G; Liza-Sharmini, A T

    2016-12-01

    PurposeThe role of microvascular endothelial dysfunction on severity of primary open angle glaucoma (POAG) was investigated in this study.Patients and methodsA prospective cohort study was conducted. One hundred and fourteen ethnically Malay patients (114 eyes) with POAG treated at the eye clinic of Hospital University Sains Malaysia between April 2012 and December 2014 were recruited. Patients aged between 40 and 80 years with two consecutive reliable and reproducible Humphrey visual field 24-2 analyses were selected. Patients who were diagnosed with any other type of glaucoma, previous glaucoma-filtering surgery, or other surgeries except uncomplicated cataract and pterygium surgery were excluded. Humphrey visual field analysis 24-2 was used to stratify the severity of glaucoma using Advanced Glaucoma Intervention Study (AGIS) score at the time of recruitment. Microvascular endothelial function was assessed using Laser Doppler fluximetry and iontophoresis. Iontophoresis process with acetylcholine (ACh) and sodium nitroprusside (SNP) was used to measure microvascular endothelium-dependent and -independent vasodilatation, respectively.ResultsBased on the AGIS score, 55 patients showed mild glaucoma, with 29 moderate and 30 severe. There was statistically significant difference in microvascular endothelial function (ACh% and ACh max ) between mild and moderate POAG cases (P=0.023) and between mild and severe POAG cases (P<0.001). There was negative correlation between microvascular endothelial function and severity of POAG (r=-0.457, P<0.001).ConclusionMicrovascular endothelial dysfunction may have a role in influencing the severity of POAG in Malay patients.

  14. Structural and functional brain changes in early- and mid-stage primary open-angle glaucoma using voxel-based morphometry and functional magnetic resonance imaging.

    PubMed

    Jiang, Ming-Ming; Zhou, Qing; Liu, Xiao-Yong; Shi, Chang-Zheng; Chen, Jian; Huang, Xiang-He

    2017-03-01

    To investigate structural and functional brain changes in patients with primary open-angle glaucoma (POAG) by using voxel-based morphometry based on diffeomorphic anatomical registration through exponentiated Lie algebra (VBM-DARTEL) and blood oxygenation level dependent functional magnetic resonance imaging (BOLD-fMRI), respectively.Thirteen patients diagnosed with POAG and 13 age- and sex-matched healthy controls were enrolled in the study. For each participant, high-resolution structural brain imaging and blood flow imaging were acquired on a 3.0-Tesla magnetic resonance imaging (MRI) scanner. Structural and functional changes between the POAG and control groups were analyzed. An analysis was carried out to identify correlations between structural and functional changes acquired in the previous analysis and the retinal nerve fiber layer (RNFL).Patients in the POAG group showed a significant (P < 0.001) volume increase in the midbrain, left brainstem, frontal gyrus, cerebellar vermis, left inferior parietal lobule, caudate nucleus, thalamus, precuneus, and Brodmann areas 7, 18, and 46. Moreover, significant (P < 0.001) BOLD signal changes were observed in the right supramarginal gyrus, frontal gyrus, superior frontal gyrus, left inferior parietal lobule, left cuneus, and left midcingulate area; many of these regions had high correlations with the RNFL.Patients with POAG undergo widespread and complex changes in cortical brain structure and blood flow. (ClinicalTrials.gov number: NCT02570867).

  15. Early Initial Antibiotics and Debridement Independently Reduce Infection in an Open Fracture Model

    DTIC Science & Technology

    2012-01-01

    infection in those Gustilo-Anderson grade III fractures whose surgery was delayed until return to the US, compared with those who underwent early...LEAP) included a prospective observational study of 315 patients with Gustilo-Anderson grade III open fractures of the tibia, foot and ankle and, in...6. Ashford RU, Mehta JA, Cripps R. Delayed presentation is no barrier to satisfactory outcome in the management of open tibial fractures . Injury

  16. Influence of Contact Angle, Growth Angle and Melt Surface Tension on Detached Solidification of InSb

    NASA Technical Reports Server (NTRS)

    Wang, Yazhen; Regel, Liya L.; Wilcox, William R.

    2000-01-01

    We extended the previous analysis of detached solidification of InSb based on the moving meniscus model. We found that for steady detached solidification to occur in a sealed ampoule in zero gravity, it is necessary for the growth angle to exceed a critical value, the contact angle for the melt on the ampoule wall to exceed a critical value, and the melt-gas surface tension to be below a critical value. These critical values would depend on the material properties and the growth parameters. For the conditions examined here, the sum of the growth angle and the contact angle must exceed approximately 130, which is significantly less than required if both ends of the ampoule are open.

  17. Identification a novel MYOC gene mutation in a Chinese family with juvenile-onset open angle glaucoma.

    PubMed

    Zhao, Xin; Yang, Chaoshan; Tong, Yi; Zhang, Xiaohui; Xu, Liang; Li, Yang

    2010-08-25

    To describe the clinical and genetic findings in one Chinese family with juvenile-onset open angle glaucoma (JOAG). One family was examined clinically and a follow-up took place 5 years later. After informed consent was obtained, genomic DNA was extracted from the venous blood of all participants. Linkage analysis was performed with three microsatellite markers around the MYOC gene (D1S196, D1S2815, and D1S218) in the family. Mutation screening of all coding exons of MYOC was performed by direct sequencing of PCR-amplified DNA fragments and restriction fragment length polymorphism (RFLP) analysis. Bioinformatics analysis by the Garnier-Osguthorpe-Robson (GOR) method predicted the effects of variants detected on secondary structures of the MYOC protein. Clinical examination and pedigree analysis revealed a three- generation family with seven members diagnosed with JOAG, three with ocular hypertension, and five normal individuals. Through genotyping, the pedigree showed a linkage to the MYOC on chromosome 1q24-25. Mutation screening of MYOC in this family revealed an A-->T transition at position 1348 (p. N450Y) of the cDNA sequence. This missense mutation co-segregated with the disease phenotype of the family, but was not found in 100 normal controls. Secondary structure prediction of the p.N450Y by the GOR method revealed the replacement of a coil with a beta sheet at the amino acid 447. Early onset JOAG, with incomplete penetrance, is consistent with a novel mutation in MYOC. The finding provides pre-symptomatic molecular diagnosis for the members of this family and is useful for further genetic consultation.

  18. Trabeculotomy combined with phacoemulsification and implantation of an intraocular lens for the treatment of primary open-angle glaucoma and coexisting cataract.

    PubMed

    Tanihara, H; Honjo, M; Inatani, M; Honda, Y; Ogino, N; Ueno, S; Negi, A; Ichioka, H; Mizoguchi, T; Matsumura, M; Nagata, M

    1997-10-01

    The authors previously reported the usefulness of trabeculotomy ab externo for the treatment of primary open-angle glaucoma in adult patients. In an attempt to elucidate the long-term risk-to-benefit ratio of this surgical modality in combination with cataract surgery, the authors conducted a retrospective study of the surgical effects and complications of a triple procedure: phacoemulsification, implantation (of an intraocular lens), and trabeculotomy (PIT). The authors conducted a retrospective study of patients treated with PIT at multiple hospitals. Intraocular pressure (IOP) and visual function data were obtained from patients after PIT as an initial surgical treatment in cases where antiglaucoma medications failed to resolve uncontrolled IOP (higher than 21 mm Hg). Included in this study were 96 eyes of 64 patients with primary open-angle glaucoma and coexisting cataract. The mean follow-up period was 22.6 +/- 14.7 months (range 3-56 months). In 94 (98%) of the 96 eyes, the IOP was well controlled, having achieved a level of 21 mm Hg or lower at the final examinations. The mean preoperative IOP of the 33 eyes that underwent the triple procedure using a single flap method (PIT-I) was 24.3 +/- 3.9 mm Hg, with an average of 2.1 +/- 1.1 medications. At the final examinations, the mean IOP had dropped to 16.0 +/- 1.2 mm Hg, with an average of 1.2 +/- 1.2 medications. The mean preoperative IOP of the 63 eyes that underwent the triple procedure using a double flap method (PIT-II) was 26.2 +/- 6.2 mm Hg, with an average of 1.9 +/- 1.2 medications. At the final examination, the mean IOP for this group was 15.6 +/- 2.9 mm Hg, with an average of 1.0 +/- 0.9 medications. The long-term results from this multicenter study showed that the triple procedure, PIT, can be useful and effective as an initial surgical treatment for open-angle glaucoma in glaucoma patients with coexisting cataract.

  19. Infant titi monkey behavior in the open field test and the effect of early adversity.

    PubMed

    Larke, Rebecca H; Toubiana, Alice; Lindsay, Katrina A; Mendoza, Sally P; Bales, Karen L

    2017-09-01

    The open field test is commonly used to measure anxiety-related behavior and exploration in rodents. Here, we used it as a standardized novel environment in which to evaluate the behavioral response of infant titi monkeys (Callicebus cupreus), to determine the effect of presence of individual family members, and to assess how adverse early experience alters infant behavior. Infants were tested in the open field for 5 days at ages 4 and 6 months in four successive 5 min trials on each day. A transport cage, which was situated on one side of the open field, was either empty (non-social control) or contained the father, mother, or sibling. Infant locomotor, vocalization, and exploratory behavior were quantified. Results indicated that age, sex, social condition, and early experience all had significant effects on infant behavior. Specifically, infants were generally more exploratory at 6 months and male infants were more exploratory than females. Infants distinguished between social and non-social conditions but made few behavioral distinctions between the attachment figure and other individuals. Infants which had adverse early life experience demonstrated greater emotional and physical independence, suggesting that early adversity led to resiliency in the novel environment. © 2017 Wiley Periodicals, Inc.

  20. Camouflage of a high-angle skeletal Class II open-bite malocclusion in an adult after mini-implant failure during treatment.

    PubMed

    Franzotti Sant'Anna, Eduardo; Carneiro da Cunha, Amanda; Paludo Brunetto, Daniel; Franzotti Sant'Anna, Claudia

    2017-03-01

    The treatment of skeletal anterior open-bite malocclusion requires complex orthodontic planning that considers its multifactorial etiology, treatment limitations, and high relapse rates. This case report illustrates a successful treatment approach for a skeletal high-angle Class II malocclusion in an adult with a severe open bite. The treatment consisted of a high-pull headgear therapy after mini-implants failure during fixed orthodontic therapy. Adequate esthetics and function were achieved. Despite its low probability, the unexpected event of mini-implant loosening during complex treatments should be considered. Therefore, classic orthodontic mechanics should be established, especially when treating patients for whom invasive procedures such as miniplates or orthognathic surgery are not available options. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  1. Repeatability of selective laser trabeculoplasty for open-angle glaucoma.

    PubMed

    Francis, Brian A; Loewen, Nils; Hong, Bryan; Dustin, Laurie; Kaplowitz, Kevin; Kinast, Robert; Bacharach, Jason; Radhakrishnan, Sunita; Iwach, Andrew; Rudavska, Lidiya; Ichhpujani, Parul; Katz, L Jay

    2016-07-28

    To analyze the results of repeat selective laser trabeculoplasty (SLT). participants with primary or secondary open-angle glaucoma (excluding uveitic) who had undergone SLT 360° (SLT 1) with diminution of response over time followed by repeat SLT 360° (SLT 2). Six months of follow-up were required and at least 6 months in between SLT 1 and 2. The main outcome measures were IOP reduction at 6 and 12 months and a comparison of the response between SLT 1 and 2. One hundred thirty-seven patients met the inclusion criteria. If only one eye had repeat treatment, that eye was chosen; if both eyes qualified, one was chosen at random. The baseline intraocular pressure (IOP) for SLT 1 = 20.3+/- 5.2 mmHg and SLT 2 = 19.4 +/- 5.0 was reduced to 16.4 +/- 3.9 and 16.7 +/- 4.7 at 1 year, respectively (p < .001). Medication use was not significantly changed, and was 2.2 +/- 1.2 at baseline for SLT 1 and 2.1 +/- 1.3 for SLT 2, and at 1 year was 1.9 +/- 1.3 and 2.2 +/- 1.2, respectively. A subanalysis of 62 patients matched for equivalent baselines showed a baseline IOP = 18.7 +/- 3.8 for SLT 1 and 18.7 +/- 3.5 for SLT 2, reduced to 16.0 +/- 4.3 and 15.3 +/- 3.8 at 1 year (p < .001). Repeat SLT laser (360-degree treatment, followed by a loss of effect over time, then a second 360-degree treatment) in this population resulted in IOP lowering similar to that of the initial treatment.

  2. Open-angle glaucoma in Filipino and white Americans: a comparative study.

    PubMed

    Sáles, Christopher S; Lee, Roland Y; Agadzi, Anthony K; Hee, Michael R; Singh, Kuldev; Lin, Shan C

    2014-01-01

    To compare the frequency of open-angle glaucoma (OAG) subtypes between Filipino and white Americans in a general ophthalmology clinic population. In this retrospective cross-sectional epidemiologic study with prospective sampling, medical charts of 1113 patients aged 40 years or older (513 Filipinos, 600 whites) seen in 2008 were randomly sampled from 2 private comprehensive ophthalmology clinics. Glaucoma was diagnosed based on optic nerve appearance, visual field defects, and other ocular findings using the International Society of Geographical and Epidemiological Ophthalmology (ISGEO) scheme. The normal-tension subtype of OAG [normal-tension glaucoma (NTG)] was defined by intraocular pressure ≤21 mm Hg as determined by review of medical records. NTG comprised a greater proportion of all glaucomatous disease in Filipino subjects [Filipino (F) vs. white (W): 46.7% vs. 26.8%; P=0.02]. Filipinos were more commonly diagnosed with OAG and NTG than whites (F vs. W: OAG, 11.9% vs. 8.2%; NTG, 6.8% vs. 2.5%; P=0.04, 0.001, respectively). There was no significant difference in central corneal thickness between Filipino and white subjects with NTG (P=0.66). Both OAG and NTG may be more common in Filipino Americans than in white Americans with the propensity for NTG being particularly high in the former relative to the latter group.

  3. An alternative early opening scenario for the Central Atlantic Ocean

    NASA Astrophysics Data System (ADS)

    Labails, Cinthia; Olivet, Jean-Louis; Aslanian, Daniel; Roest, Walter R.

    2010-09-01

    The opening of the Central Atlantic Ocean basin that separated North America from northwest Africa is well documented and assumed to have started during the Late Jurassic. However, the early evolution and the initial breakup history of Pangaea are still debated: most of the existing models are based on one or multiple ridge jumps at the Middle Jurassic leaving the oldest crust on the American side, between the East Coast Magnetic Anomaly (ECMA) and the Blake Spur Magnetic Anomaly (BSMA). According to these hypotheses, the BSMA represents the limit of the initial basin and the footprint subsequent to the ridge jump. Consequently, the evolution of the northwest African margin is widely different from the northeast American margin. However, this setting is in contradiction with the existing observations. In this paper, we propose an alternative scenario for the continental breakup and the Mesozoic spreading history of the Central Atlantic Ocean. The new model is based on an analysis of geophysical data (including new seismic lines, an interpretation of the newly compiled magnetic data, and satellite derived gravimetry) and recently published results which demonstrate that the opening of the Central Atlantic Ocean started already during the Late Sinemurian (190 Ma), based on a new identification of the African conjugate to the ECMA and on the extent of salt provinces off Morocco and Nova Scotia. The identification of an African conjugate magnetic anomaly to BSMA, the African Blake Spur Magnetic Anomaly (ABSMA), together with the significant change in basement topography, are in good agreement with that initial reconstruction. The early opening history for the Central Atlantic Ocean is described in four distinct phases. During the first 20 Myr after the initial breakup (190-170 Ma, from Late Sinemurian to early Bajocian), oceanic accretion was extremely slow (˜ 0.8 cm/y). At the time of Blake Spur (170 Ma, early Bajocian), a drastic change occurred both in the relative

  4. Interocular asymmetry of the visual field defects in newly diagnosed normal-tension glaucoma, primary open-angle glaucoma, and chronic angle-closure glaucoma.

    PubMed

    Huang, Ping; Shi, Yan; Wang, Xin; Liu, Mugen; Zhang, Chun

    2014-09-01

    To compare the interocular asymmetry of visual field loss in newly diagnosed normal-tension glaucoma (NTG), primary open-angle glaucoma (POAG), and chronic angle-closure glaucoma (CACG) patients. Visual field results of 117 newly diagnosed, treatment-naive glaucoma patients (42 NTG, 38 POAG, and 37 CACG) were studied retrospectively. The following 3 visual field defect parameters were used to evaluate the interocular asymmetry: (1) global indices; (2) local mean deviations (MDs) of 6 predefined visual field areas; and (3) stage designated by glaucoma staging system 2. The differences of the above parameters between the trial eye (the eye with greater MDs) and the fellow eye in each subject were defined as interocular asymmetry scores. Interocular asymmetry of visual field loss was presented in all the 3 groups (all P<0.05). CACG group had greater total MD interocular asymmetry score compared with the NTG and POAG groups (among groups, P=0.008; NTG vs. CACG, P=0.005; POAG vs. CACG, P=0.009). CACG also presented with significantly higher local MD interocular asymmetry scores at central, inferior, and temporal areas compared with those of the POAG group and at inferior area compared with that of NTG group. No significant difference in either total or local MDs was detected between NTG and POAG (all P>0.05). Interocular asymmetry scores of glaucoma staging system 2 had no significant difference among the 3 groups (P=0.068). All CACG, POAG, and NTG groups presented with interocular asymmetric visual field loss at the time of diagnosis. CACG had greater interocular asymmetry compared with NTG and POAG. No significant interocular asymmetry difference was observed between NTG and POAG.

  5. Distinct iris gene expression profiles of primary angle closure glaucoma and primary open angle glaucoma and their interaction with ocular biometric parameters.

    PubMed

    Seet, Li-Fong; Narayanaswamy, Arun; Finger, Sharon N; Htoon, Hla M; Nongpiur, Monisha E; Toh, Li Zhen; Ho, Henrietta; Perera, Shamira A; Wong, Tina T

    2016-11-01

    This study aimed to evaluate differences in iris gene expression profiles between primary angle closure glaucoma (PACG) and primary open angle glaucoma (POAG) and their interaction with biometric characteristics. Prospective study. Thirty-five subjects with PACG and thirty-three subjects with POAG who required trabeculectomy were enrolled at the Singapore National Eye Centre, Singapore. Iris specimens, obtained by iridectomy, were analysed by real-time polymerase chain reaction for expression of type I collagen, vascular endothelial growth factor (VEGF)-A, -B and -C, as well as VEGF receptors (VEGFRs) 1 and 2. Anterior segment optical coherence tomography (ASOCT) imaging for biometric parameters, including anterior chamber depth (ACD), anterior chamber volume (ACV) and lens vault (LV), was also performed pre-operatively. Relative mRNA levels between PACG and POAG irises, biometric measurements, discriminant analyses using genes and biometric parameters. COL1A1, VEGFB, VEGFC and VEGFR2 mRNA expression was higher in PACG compared to POAG irises. LV, ACD and ACV were significantly different between the two subgroups. Discriminant analyses based on gene expression, biometric parameters or a combination of both gene expression and biometrics (LV and ACV), correctly classified 94.1%, 85.3% and 94.1% of the original PACG and POAG cases, respectively. The discriminant function combining genes and biometrics demonstrated the highest accuracy in cross-validated classification of the two glaucoma subtypes. Distinct iris gene expression supports the pathophysiological differences that exist between PACG and POAG. Biometric parameters can combine with iris gene expression to more accurately define PACG from POAG. © 2016 The Authors. Clinical & Experimental Ophthalmology published by John Wiley & Sons Australia, Ltd on behalf of Royal Australian and New Zealand College of Ophthalmologists.

  6. Application of Bayes' to the prediction of referral decisions made by specialist optometrists in relation to chronic open angle glaucoma.

    PubMed

    Gurney, J C; Ansari, E; Harle, D; O'Kane, N; Sagar, R V; Dunne, M C M

    2018-02-09

    To determine the accuracy of a Bayesian learning scheme (Bayes') applied to the prediction of clinical decisions made by specialist optometrists in relation to the referral refinement of chronic open angle glaucoma. This cross-sectional observational study involved collection of data from the worst affected or right eyes of a consecutive sample of cases (n = 1,006) referred into the West Kent Clinical Commissioning Group Community Ophthalmology Team (COT) by high street optometrists. Multilevel classification of each case was based on race, sex, age, family history of chronic open angle glaucoma, reason for referral, Goldmann Applanation Tonometry (intraocular pressure and interocular asymmetry), optic nerve head assessment (vertical size, cup disc ratio and interocular asymmetry), central corneal thickness and visual field analysis (Hodapp-Parrish-Anderson classification). Randomised stratified tenfold cross-validation was applied to determine the accuracy of Bayes' by comparing its output to the clinical decisions of three COT specialist optometrists; namely, the decision to discharge, follow-up or refer each case. Outcomes of cross-validation, expressed as means and standard deviations, showed that the accuracy of Bayes' was high (95%, 2.0%) but that it falsely discharged (3.4%, 1.6%) or referred (3.1%, 1.5%) some cases. The results indicate that Bayes' has the potential to augment the decisions of specialist optometrists.

  7. Common variants near CAV1 and CAV2 are associated with primary open-angle glaucoma

    PubMed Central

    Thorleifsson, Gudmar; Walters, G Bragi; Hewitt, Alex W; Masson, Gisli; Helgason, Agnar; DeWan, Andrew; Sigurdsson, Asgeir; Jonasdottir, Adalbjorg; Gudjonsson, Sigurjon A; Magnusson, Kristinn P; Stefansson, Hreinn; Lam, Dennis S C; Tam, Pancy O S; Gudmundsdottir, Gudrun J; Southgate, Laura; Burdon, Kathryn P; Gottfredsdottir, Maria Soffia; Aldred, Micheala A; Mitchell, Paul; St Clair, David; Collier, David A; Tang, Nelson; Sveinsson, Orn; Macgregor, Stuart; Martin, Nicholas G; Cree, Angela J; Gibson, Jane; MacLeod, Alex; Jacob, Aby; Ennis, Sarah; Young, Terri L; Chan, Juliana C N; Karwatowski, Wojciech S S; Hammond, Christopher J; Thordarson, Kristjan; Zhang, Mingzhi; Wadelius, Claes; Lotery, Andrew J; Trembath, Richard C; Pang, Chi Pui; Hoh, Josephine; Craig, Jamie E; Kong, Augustine; Mackey, David A; Jonasson, Fridbert; Thorsteinsdottir, Unnur; Stefansson, Kari

    2011-01-01

    We conducted a genome-wide association study for primary open-angle glaucoma (POAG) in 1,263 affected individuals (cases) and 34,877 controls from Iceland. We identified a common sequence variant at 7q31 (rs4236601[A], odds ratio (OR) = 1.36, P = 5.0 × 10-10). We then replicated the association in sample sets of 2,175 POAG cases and 2,064 controls from Sweden, the UK and Australia (combined OR = 1.18, P = 0.0015) and in 299 POAG cases and 580 unaffected controls from Hong Kong and Shantou, China (combined OR = 5.42, P = 0.0021). The risk variant identified here is located close to CAV1 and CAV2, both of which are expressed in the trabecular meshwork and retinal ganglion cells that are involved in the pathogenesis of POAG. PMID:20835238

  8. Risk Factors Associated with Progression to Blindness from Primary Open-Angle Glaucoma in an African-American Population

    PubMed Central

    Pleet, Alexander; Sulewski, Melanie; Salowe, Rebecca J.; Fertig, Raymond; Salinas, Julia; Rhodes, Allison; Merritt, William; Natesh, Vikas; Huang, Jiayan; Gudiseva, Harini V.; Collins, David W.; Chavali, Venkata Ramana Murthy; Tapino, Paul; Lehman, Amanda; Regina-Gigiliotti, Meredith; Miller-Ellis, Eydie; Sankar, Prithvi; Ying, Gui-Shuang; O’Brien, Joan M.

    2016-01-01

    Purpose To determine the risk factors associated with progression to blindness from primary open-angle glaucoma (POAG) in an African-American population. Methods This study examined 2119 patients enrolled in the Primary Open-Angle African-American Glaucoma Genetics (POAAGG) study. A total of 59 eyes were identified as legally blind as a result of POAG (cases) and were age-and sex-matched to 59 non-blind eyes with glaucoma (controls). Chart reviews were performed to record known and suspected risk factors. Results Cases were diagnosed with POAG at an earlier age than controls (p = 0.005). Of the 59 eyes of cases, 16 eyes (27.1%) presented with blindness at diagnosis. Cases had worse visual acuity (VA) at diagnosis (p < 0.0001), with VA worse than 20/40 conferring a 27 times higher risk of progression to blindness (p = 0.0005). Blind eyes also demonstrated more visual field defects (p = 0.01), higher pretreatment intraocular pressure (IOP; p < 0.0001), and higher cup-to-disc ratio (p = 0.006) at diagnosis. IOP was less controlled in cases, and those with IOP ≥21 mmHg at more than 20% of follow-up visits were 73 times more likely to become blind (p < 0.0001). Cases missed a greater number of appointments per year (p = 0.003) and had non-adherence issues noted in their charts more often than controls (p = 0.03). However, other compliance data did not significantly differ between groups. Conclusion Access to care, initial VA worse than 20/40, and poor control of IOP were the major risk factors associated with blindness from POAG. Future studies should examine earlier, more effective approaches to glaucoma screening as well as the role of genetics in these significantly younger patients who progress to blindness. PMID:27348239

  9. Risk Factors Associated with Progression to Blindness from Primary Open-Angle Glaucoma in an African-American Population.

    PubMed

    Pleet, Alexander; Sulewski, Melanie; Salowe, Rebecca J; Fertig, Raymond; Salinas, Julia; Rhodes, Allison; Merritt Iii, William; Natesh, Vikas; Huang, Jiayan; Gudiseva, Harini V; Collins, David W; Chavali, Venkata Ramana Murthy; Tapino, Paul; Lehman, Amanda; Regina-Gigiliotti, Meredith; Miller-Ellis, Eydie; Sankar, Prithvi; Ying, Gui-Shuang; O'Brien, Joan M

    2016-08-01

    To determine the risk factors associated with progression to blindness from primary open-angle glaucoma (POAG) in an African-American population. This study examined 2119 patients enrolled in the Primary Open-Angle African-American Glaucoma Genetics (POAAGG) study. A total of 59 eyes were identified as legally blind as a result of POAG (cases) and were age-and sex-matched to 59 non-blind eyes with glaucoma (controls). Chart reviews were performed to record known and suspected risk factors. Cases were diagnosed with POAG at an earlier age than controls (p = 0.005). Of the 59 eyes of cases, 16 eyes (27.1%) presented with blindness at diagnosis. Cases had worse visual acuity (VA) at diagnosis (p < 0.0001), with VA worse than 20/40 conferring a 27 times higher risk of progression to blindness (p = 0.0005). Blind eyes also demonstrated more visual field defects (p = 0.01), higher pre-treatment intraocular pressure (IOP; p < 0.0001), and higher cup-to-disc ratio (p = 0.006) at diagnosis. IOP was less controlled in cases, and those with IOP ≥21 mmHg at more than 20% of follow-up visits were 73 times more likely to become blind (p < 0.0001). Cases missed a greater number of appointments per year (p = 0.003) and had non-adherence issues noted in their charts more often than controls (p = 0.03). However, other compliance data did not significantly differ between groups. Access to care, initial VA worse than 20/40, and poor control of IOP were the major risk factors associated with blindness from POAG. Future studies should examine earlier, more effective approaches to glaucoma screening as well as the role of genetics in these significantly younger patients who progress to blindness.

  10. The Association Between Body Mass Index and Open-angle Glaucoma in a South Korean Population-based Sample.

    PubMed

    Lin, Shuai-Chun; Pasquale, Louis R; Singh, Kuldev; Lin, Shan C

    2018-03-01

    The purpose of this article is to investigate the association between body mass index (BMI) and open-angle glaucoma (OAG) in a sample of the South Korean population. The sample consisted of a cross-sectional, population-based sample of 10,978 participants, 40 years of age and older, enrolled in the 2008 to 2011 Korean National Health and Nutrition Examination Survey. All participants had measured intraocular pressure <22 mm Hg and open anterior chamber angles. OAG was defined using disc and visual field criteria established by the International Society for Geographical and Epidemiological Ophthalmology. Multivariable analyses were performed to determine the association between BMI and OAG. These analyses were also performed in a sex-stratified and age-stratified manner. After adjusting for potential confounding variables, lower BMI (<19 kg/m) was associated with greater risk of OAG compared with normal BMI (19 to 24.9 kg/m) [odds ratio (OR), 2.28; 95% confidence interval (CI), 1.22-4.26]. In sex-stratified analyses, low BMI remained adversely related to glaucoma in women (OR, 3.45; 95% CI, 1.42-8.38) but not in men (OR, 1.72; 95% CI, 0.71-4.20). In age-stratified analyses, lower BMI was adversely related to glaucoma among subjects 40- to 49-year old (OR, 5.16; 95% CI, 1.86-14.36) but differences in glaucoma prevalence were not statistically significant between those with low versus normal BMI in other age strata. Lower BMI was associated with increased odds of OAG in a sample of the South Korean population. Multivariate analysis revealed the association to be statistically significant in women and those in the youngest age stratum.

  11. High prevalence of narrow angles among Chinese-American glaucoma and glaucoma suspect patients.

    PubMed

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data were collected for sex, age, race (self-declared), refraction (spherical equivalent), intraocular pressure, gonioscopy, and vertical cup-to-disk ratio. Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade < or = 2 in 3 or more quadrants). Those with narrow angles were significantly older (P=0.004) than their open angle counterparts, but the 2 groups did not differ in terms of sex, refraction, intraocular pressure, or cup-to-disk ratio (all, P > or = 0.071). In a multivariate model including age, sex, and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of sex or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed.

  12. Visual disability in newly diagnosed primary open angle glaucoma (POAG) patients in a tertiary hospital in Nigeria.

    PubMed

    Awoyesuku, E A; Ejimadu, C S

    2012-01-01

    Glaucoma remains the second leading cause of blindness worldwide and the highes cause of irreversible blindness worldwide. In N Glaucoma accounts for 16% of blindness and primary open angle glaucoma is the most prevalent clinical type. The aim of this study is to assess the visual disability resulting from glaucoma in newly diagnosed POAG patients in University of Port Harcourt Teaching Hospital. This is a retrospective study of newly diagnosed glaucoma patients referred from the general ophthalmology clinic to the glaucoma clinic over a 12 month period (January-December 2010). All patients had a glaucoma workup includin Snellen distant visual acuity, slit lamp examination, Goldman applanation tonometry, gonioscopy, dilated fundoscopy with +78 diopter lens as well as perimetry. All examinations were carried out by both authors. Patients with other co-morbidities such as cataract and retinal/macular pathologies were excluded from the study. A total of 98 patients were reviewed. The were 34 males and 27 females, giving a male to female ratio of 1.3:1. The average age was 54.2 years and most patients (>80%) were in the 40-59 year age group. Of the 98 patients reviewed, 62.2% had POAG. 30 patients were-blind by distant visual acuity criteria while 45 patients were blind by central visual field criteria. POAG is the most prevalent clinical subtype of glaucoma in Nigeria and sub-Saharan Africa Paucity of symptoms in early stages of the disease at late presentation is a characteristic finding in our clinic environment. Our study showed that POAG in our environment is associated with marked visual disability at the time of presentation.

  13. Factors associated with lifetime risk of open-angle glaucoma blindness.

    PubMed

    Peters, Dorothea; Bengtsson, Boel; Heijl, Anders

    2014-08-01

    To investigate factors associated with bilateral glaucoma blindness, particularly factors available at the time of diagnosis. Retrospective chart review of all patients with primary open-angle glaucoma (POAG) or pseudoexfoliative glaucoma (PEXG) followed at the Department of Ophthalmology or Low Vision Center of Skåne University Hospital, Malmö, Sweden, who died between January 2006 and June 2010. Disease stage at diagnosis was defined by a simplified version of Mills' glaucoma staging system using perimetric mean deviation (MD) to define six stages of severity. Blindness was defined according to WHO criteria. We used logistic regression analysis to examine the association between risk factors and glaucoma blindness. Four hundred and 23 patients were included; 60% POAG and 40% PEXG. Sixty-four patients (15%) became blind from glaucoma. Blind patients had significantly longer mean duration with diagnosed disease than patients who did not go blind (14.8 years ± 5.8 versus 10.6 years ± 6.5, p < 0.001). The risk of blindness increased with higher intraocular pressure (IOP) (OR 1.08, 95% CI 1.03-1.13) and with each stage of more advanced field loss at time of diagnosis (OR 1.80 95% CI 1.34-2.41). Older age at death was also associated with an increased risk of blindness (OR 1.09 95% CI 1.03-1.14), while age at diagnosis was unimportant. PEXG was not an independent risk factor for blindness. Higher IOP and worse visual field status at baseline were important risk factors, as was older age at death. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  14. Do non-communicable diseases such as hypertension and diabetes associate with primary open-angle glaucoma? Insights from a case-control study in Nepal.

    PubMed

    Shakya-Vaidya, Suraj; Aryal, Umesh Raj; Upadhyay, Madan; Krettek, Alexandra

    2013-11-04

    Non-communicable diseases (NCDs) such as hypertension and diabetes are rapidly emerging public health problems worldwide, and they associate with primary open-angle glaucoma (POAG). POAG is the most common cause of irreversible blindness. The most effective ways to prevent glaucoma blindness involve identifying high-risk populations and conducting routine screening for early case detection. This study investigated whether POAG associates with hypertension and diabetes in a Nepalese population. To explore the history of systemic illness, our hospital-based case-control study used non-random consecutive sampling in the general eye clinics in three hospitals across Nepal to enroll patients newly diagnosed with POAG and controls without POAG. The study protocol included history taking, ocular examination, and interviews with 173 POAG cases and 510 controls. Data analysis comprised descriptive and inferential statistics. Descriptive statistics computed the percentage, mean, and standard deviation (SD); inferential statistics used McNemar's test to measure associations between diseases. POAG affected males more frequently than females. The odds of members of the Gurung ethnic group having POAG were 2.05 times higher than for other ethnic groups. Hypertension and diabetes were strongly associated with POAG. The overall odds of POAG increased 2.72-fold among hypertensive and 3.50-fold among diabetic patients. POAG associates significantly with hypertension and diabetes in Nepal. Thus, periodic glaucoma screening for hypertension and diabetes patients in addition to opportunistic screening at eye clinics may aid in detecting more POAG cases at an early stage and hence in reducing avoidable blindness.

  15. Mild angle early onset idiopathic scoliosis children avoid progression under FITS method (Functional Individual Therapy of Scoliosis).

    PubMed

    Białek, Marianna

    2015-05-01

    Physiotherapy for stabilization of idiopathic scoliosis angle in growing children remains controversial. Notably, little data on effectiveness of physiotherapy in children with Early Onset Idiopathic Scoliosis (EOIS) has been published.The aim of this study was to check results of FITS physiotherapy in a group of children with EOIS.The charts of the patients archived in a prospectively collected database were retrospectively reviewed. The inclusion criteria were:diagnosis of EOIS based on spine radiography, age below 10 years, both girls and boys, Cobb angle between 118 and 308, Risser zero, FITS therapy, no other treatment (bracing), and a follow-up at least 2 years from the initiation of the treatment. The criterion for curve progression were as follows: the Cobb angle increase of 68 or more, for curve stabilization; the Cobb angle was 58 comparing to the initial radiograph,for curve correction; and the Cobb angle decrease of 68 or more at the final follow-up radiograph.There were 41 children with EOIS, 36 girls and 5 boys, mean age 7.71.3 years (range 4 to 9 years) who started FITS therapy. The curve pattern was single thoracic (5 children), single thoracolumbar (22 children) or double thoracic/thoracolumbar (14 children), totally 55 structural curvatures. The minimum follow-up was 2 years after initiation of the FITS treatment, maximum was 16 years, mean 4.8 years). At follow-up the mean age was 12.53.4 years. Out of 41 children, 10 passed pubertal growth spurt at the final follow-up and 31 were still immature and continued FITS therapy. Out of 41 children, 27 improved, 13 were stable, and one progressed. Out of 55 structural curves, 32 improved, 22 were stable and one progressed. For the 55 structural curves, the Cobb angle significantly decreased from 18.085.48 at first assessment to 12.586.38 at last evaluation,p<0.0001, paired t-test. The angle of trunk rotation decreased significantly from 4.782.98 to 3.282.58 at last evaluation, p<0.0001,paired t

  16. High Prevalence of Narrow Angles among Chinese-American Glaucoma and Glaucoma Suspect Patients

    PubMed Central

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    Purpose To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Patients and Methods Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data was collected for gender, age, race (self-declared), refraction (spherical equivalent), intraocular pressure (IOP), gonioscopy and vertical cup-to-disk ratio (CDR). Results Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade ≤2 in three or more quadrants). Those with narrow angles were significantly older (P=0.004) than their open angle counterparts, but the two groups did not differ in terms of gender, refraction, IOP or CDR (all, P≥0.071). In a multivariate model including age, gender and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). Conclusions A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of gender or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed. PMID:19826385

  17. Examining Delay Intervals in the Diagnosis and Treatment of Primary Open Angle Glaucoma in an Egyptian Population and Its Impact on Lifestyle

    PubMed Central

    Abu Hussein, Nahla B.; Habib, Ahmed E.; El Sayed, Yasmine M.

    2016-01-01

    Purpose. To examine causes as well as extent of delay in diagnosis and treatment of primary open angle glaucoma patients in a sample of Egyptians. Patients and Methods. 440 patients with primary open angle glaucoma were interviewed to evaluate delay in their diagnosis and treatment. The extent and cause of delay were investigated. The total delay interval, if any, was correlated with socioeconomic and other factors. Results. The median total delay was one year, with 50% of patients having a total delay of 1 year or less, of which 25% exhibited zero total delay. 25% of patients had a delay ranging from 1 to 3 years, and 25% had a total delay ranging from 3 to 27 years. Diagnostic delay accounted for 43.03% of cases. Longer delays were met in patients with certain socioeconomic factors. Patients with a positive family history of glaucoma displayed shorter delay periods. Conclusion. Significant delay in the diagnosis and treatment of glaucoma was found. Poor socioeconomic status seems to hinder timely diagnosis and treatment of POAG. Certain socioeconomic factors seem to correlate with the extent of delay. More effort is thus needed to subsidize the cost of investigations and treatment for glaucoma patients. PMID:28116140

  18. Tilt angle dependence of backscattering enhancements from organ pipe modes of open water-filled cylinders: Measurements and models

    NASA Astrophysics Data System (ADS)

    Osterhoudt, Curtis F.; Marston, Philip L.

    2003-04-01

    A simple target for simulating narrow low-frequency resonances of cylinders is an open metal pipe completely filled with water. We have previously described how the high-Q organ-pipe modes having a pressure node near each end are easily observed in backscattering experiments with small cylinders [C. F. Osterhoudt and P. L. Marston, J. Acoust. Soc. Am. 110, 2773 (2001)]. The resonance occurs because of the strong reflection of internal acoustic waves from the open ends of the pipe [H. Levine and J. Schwinger, Phys. Rev. 73, 383-406 (1948)]. In the present research, the dependence of the backscattering amplitude on the orientation of the cylinder is measured and modeled. The tilt angle dependence is affected by the symmetry of the organ pipe mode. An approximation was also developed for the backscattering amplitude at high Q resonances based on energy conservation, reciprocity, and the optical theorem. While this analysis applies to cylinders suspended in water away from boundaries, the organ-pipe modes studied may be useful for investigating scattering processes for buried or partially buried cylinders. [Research supported in part by ONR.

  19. Diode laser trabeculoplasty in open angle glaucoma: 50 micron vs. 100 micron spot size.

    PubMed

    Veljko, Andreić; Miljković, Aleksandar; Babić, Nikola

    2011-01-01

    The study was aimed at evaluating the efficacy of diode laser trabeculoplsaty in lowering intraocular pressure in patients with both primary open-angle glaucoma and exfoliation glaucoma by using different size of laser spot. This six-month, unmasked, controlled, prospective study included sixty-two patients with the same number of eyes, who were divided into two groups. Trabeculoplasty was performed with 50 micron and 100 micron laser spot size in the group I and group II, respectively. Other laser parameters were the same for both groups: the wave length of 532 nm, 0.1 second single emission with the power of 600-1200 mW was applied on the 180 degrees of the trabeculum. The mean intraocular pressure decrease in the 50 micron group (group 1) on day 7 was 24% from the baseline and after six-month follow-up period the intraocular pressure decrease was 29.8% (p < 0.001). In the 100 micron group (group II), the mean intraocular pressure decrease on day 7 was 26.5% and after six months it was 39% (p < 0.001).

  20. Angle imaging: Advances and challenges

    PubMed Central

    Quek, Desmond T L; Nongpiur, Monisha E; Perera, Shamira A; Aung, Tin

    2011-01-01

    Primary angle closure glaucoma (PACG) is a major form of glaucoma in large populous countries in East and South Asia. The high visual morbidity from PACG is related to the destructive nature of the asymptomatic form of the disease. Early detection of anatomically narrow angles is important and the subsequent prevention of visual loss from PACG depends on an accurate assessment of the anterior chamber angle (ACA). This review paper discusses the advantages and limitations of newer ACA imaging technologies, namely ultrasound biomicroscopy, Scheimpflug photography, anterior segment optical coherence tomography and EyeCam, highlighting the current clinical evidence comparing these devices with each other and with clinical dynamic indentation gonioscopy, the current reference standard. PMID:21150037

  1. The association between clinical parameters and glaucoma-specific quality of life in Chinese primary open-angle glaucoma patients.

    PubMed

    Lee, Jacky W Y; Chan, Catherine W S; Chan, Jonathan C H; Li, Q; Lai, Jimmy S M

    2014-08-01

    OBJECTIVE. To investigate the association between clinical measurements and glaucoma-specific quality of life in Chinese glaucoma patients. DESIGN. Cross-sectional study. SETTING. An academic hospital in Hong Kong. PATIENTS. A Chinese translation of the Glaucoma Quality of Life-15 questionnaire was completed by 51 consecutive patients with bilateral primary open-angle glaucoma. The binocular means of several clinical measurements were correlated with Glaucoma Quality of Life-15 findings using Pearson's correlation coefficient and linear regression. The measurements were the visual field index and pattern standard deviation from the Humphrey Field Analyzer, Snellen best-corrected visual acuity, presenting intra-ocular pressure, current intra-ocular pressure, average retinal nerve fibre layer thickness via optical coherence tomography, and the number of topical anti-glaucoma medications being used. RESULTS. In these patients, there was a significant correlation and linear relationship between a poorer Glaucoma Quality of Life-15 score and a lower visual field index (r=0.3, r(2)=0.1, P=0.01) and visual acuity (r=0.3, r(2)=0.1, P=0.03). A thinner retinal nerve fibre layer also correlated with a poorer Glaucoma Quality of Life-15 score, but did not attain statistical significance (r=0.3, P=0.07). There were no statistically significant correlations for the other clinical parameters with the Glaucoma Quality of Life-15 scores (all P values being >0.7). The three most problematic activities affecting quality of life were "adjusting to bright lights", "going from a light to a dark room or vice versa", and "seeing at night". CONCLUSION. For Chinese primary open-angle glaucoma patients, binocular visual field index and visual acuity correlated linearly with glaucoma-specific quality of life, and activities involving dark adaptation were the most problematic.

  2. [Computer-assisted multimedia interactive learning program "Primary Open-Angle Glaucoma"].

    PubMed

    Dick, V B; Zenz, H; Eisenmann, D; Tekaat, C J; Wagner, R; Jacobi, K W

    1996-05-01

    Advances in the area of information technology have opened up new possibilities for the use of interactive media in the training of medical students. Classical instructional technologies, such as video, slides, audio cassettes and computer programs with a textbook orientation, have been merged into one multimedia computer system. The medical profession has been increasingly integrating computer-based applications which can be used, for example, for record keeping within a medical practice. The goal of this development is to provide access to all modes of information storage and retrieval as well as documentation and training systems within a specific context. Since the beginning of the winter semester 1995, the Department of Ophthalmology in Giessen has used the learning program "Primary Open Angle Glaucoma" in student instruction. One factor that contributed to the implementation of this project was that actual training using patients within the clinic is difficult to conduct. Media-supported training that can provide a simulation of actual practice offers a suitable substitute. The learning program has been installed on Power PCs (Apple MacIntosh), which make up the technical foundation of our system. The program was developed using Hypercard software, which provides userfriendly graphical work environment. This controls the input and retrieval of data, direct editing of documents, immediate simulation, the creation of on-screen documents and the integration of slides that have been scanned in as well as QuickTime films. All of this can be accomplished without any special knowledge of programming language or operating systems on the part of the user. The glaucoma learning program is structured along the lines of anatomy, including an explanation of the circulation of the aqueous humor, pathology, clinical symptoms and findings, diagnosis and treatment. This structure along with the possibility for creating a list of personal files for the user with a collection

  3. Mitral Valve Stenosis after Open Repair Surgery for Non-rheumatic Mitral Valve Regurgitation: A Review.

    PubMed

    Shabsigh, Muhammad; Lawrence, Cassidy; Rosero-Britton, Byron R; Kumar, Nicolas; Kimura, Satoshi; Durda, Michael Andrew; Essandoh, Michael

    2016-01-01

    Mitral stenosis (MS) after mitral valve (MV) repair is a slowly progressive condition, usually detected many years after the index MV surgery. It is defined as a mean transmitral pressure gradient (TMPG) >5 mmHg or a mitral valve area (MVA) <1.5 cm(2). Pannus formation around the mitral annulus or extending to the mitral leaflets is suggested as the main mechanism for developing delayed MS after MV repair. On the other hand, early stenosis is thought to be a direct result of an undersized annuloplasty ring. Furthermore, in MS following ischemic mitral regurgitation (MR) repair, subvalvular tethering is the hypothesized pathophysiology. MS after MV repair has an incidence of 9-54%. Several factors have been associated with a higher risk for developing MS after MV repair, including the use of flexible Duran annuloplasty rings versus rigid Carpentier-Edwards rings, complete annuloplasty rings versus partial bands, small versus large anterior leaflet opening angle, and anterior leaflet tip opening length. Intraoperative echocardiography can measure the anterior leaflet opening angle, the anterior leaflet tip opening dimension, the MVA and the mean TMPG, and may help identify patients at risk for developing MS after MV repair.

  4. Mitral Valve Stenosis after Open Repair Surgery for Non-rheumatic Mitral Valve Regurgitation: A Review

    PubMed Central

    Shabsigh, Muhammad; Lawrence, Cassidy; Rosero-Britton, Byron R.; Kumar, Nicolas; Kimura, Satoshi; Durda, Michael Andrew; Essandoh, Michael

    2016-01-01

    Mitral stenosis (MS) after mitral valve (MV) repair is a slowly progressive condition, usually detected many years after the index MV surgery. It is defined as a mean transmitral pressure gradient (TMPG) >5 mmHg or a mitral valve area (MVA) <1.5 cm2. Pannus formation around the mitral annulus or extending to the mitral leaflets is suggested as the main mechanism for developing delayed MS after MV repair. On the other hand, early stenosis is thought to be a direct result of an undersized annuloplasty ring. Furthermore, in MS following ischemic mitral regurgitation (MR) repair, subvalvular tethering is the hypothesized pathophysiology. MS after MV repair has an incidence of 9–54%. Several factors have been associated with a higher risk for developing MS after MV repair, including the use of flexible Duran annuloplasty rings versus rigid Carpentier–Edwards rings, complete annuloplasty rings versus partial bands, small versus large anterior leaflet opening angle, and anterior leaflet tip opening length. Intraoperative echocardiography can measure the anterior leaflet opening angle, the anterior leaflet tip opening dimension, the MVA and the mean TMPG, and may help identify patients at risk for developing MS after MV repair. PMID:27148540

  5. Open conformation of a substrate-binding cleft: sup 19 F NMR studies of cleft angle in the D-galactose chemosensory receptor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luck, L.A.; Falke, J.J.

    1991-07-02

    The Escherichia coli D-galactose and D-glucose receptor is a two-domain structure with a sugar-binding site at the interface between domains. The structure of the closed cleft containing bound D-glucose has been determined crystalloghraphically, but the open cleft remains to be characterized. The present study illustrates a generalizable approach that is used to detect and analyze both the open- and closed-cleft conformations in solution. A {sup 19}F nucleus located inside the cleft is monitored by {sup 19}F NMR. When the cleft is occupied by D-glucose, the {sup 19}F nucleus is found to be inaccessible to the aqueous paramagnetic probe Gd{center dot}EDTA,more » verifying that the occupied cleft is closed in solution and inaccessible to bulk solvent. When the cleft is empty, the {sup 19}F nucleus becomes accessible to the paramagnet such that the distance of closest approach is r {le} 10 {angstrom}, indicating that the empty cleft opens at least transiently by an angle {theta} {ge} 18 {plus minus} 3{degrees}.« less

  6. Impact of Socioeconomic Status on the Diagnosis of Primary Open-Angle Glaucoma and Primary Angle Closure Glaucoma: A Nationwide Population-Based Study in Taiwan.

    PubMed

    Ko, Yu-Chieh; Hwang, De-Kuang; Chen, Wei-Ta; Lee, Ching-Chih; Liu, Catherine J

    2016-01-01

    To understand the impact of socioeconomic status (SES) on the diagnosis of primary open-angle glaucoma (POAG) and primary angle closure glaucoma (PACG) in Taiwan. Subjects with glaucoma were identified from the National Health Insurance Research Database of year 2006, which included one million randomly selected insurants. Individuals who had ≥4 ambulatory visits within one year which had the diagnosis code of POAG (ICD-9-CM 365.11 or 365.12) or PACG (365.23) and concurrent prescription of anti-glaucoma medication or surgery were selected. Individual SES was represented by monthly income calculated from the insurance premium. Neighborhood SES was defined based on neighborhood household income averages. Urbanization level of habitation was categorized into 3 levels. The odds ratio of having POAG or PACG in subjects with different SES was evaluated by using multiple logistic regression analysis. In total, 752 and 561 subjects with POAG and PACG, respectively, who were treated on a regular basis, were identified. The diagnosis of glaucoma was affected by age, gender, frequency of healthcare utilization, individual SES, and urbanization level of habitation. With the adjustment of age, gender, healthcare utilization, neighborhood SES and level of urbanization, subjects with lower income were more likely to be diagnosed as PACG, but less likely as POAG. Subjects with more frequent healthcare utilization were more likely to be diagnosed with glaucoma. Subjects with low SES were more susceptible to PACG, but subjects with high SES were more likely to be diagnosed as POAG. This information is useful for the design and target participant setting in glaucoma education and screening campaign to maximize the efficacy of limited resources in preventing glaucoma blindness.

  7. Effect of caffeine on the intraocular pressure in patients with primary open angle glaucoma

    PubMed Central

    Chandra, Peeyush; Gaur, Ajit; Varma, Shambhu

    2011-01-01

    Purpose Coffee and tea are very common nonalcoholic beverages. However, their intake, particularly that of coffee, has been suggested to increase intraocular pressure (IOP) in patients with open angle glaucoma/ocular hypertension. The causative agent has been suggested to be their caffeine content. The objective of this study was to determine if this represents a direct caffeine effect. This study was therefore done using pure caffeine applied directly to the eyes. Methods The study was conducted with five human volunteers with open angle glaucoma/ ocular hypertension. IOP was measured using a Perkins applanation tonometer. Eye drops of 1% caffeine were prepared in-home. Following the initial (basal) measurement of the IOP, 50 μL of the eye drop preparation was instilled in the eye at 0-, 4-, and 6-hour intervals. IOPs were measured 30 minutes after each instillation. A second study was also undertaken following the first. In this study, the same patients instilled the eye drops three times per day for 1 week at home and then returned to the clinic on day 7. They were then again treated with caffeine eye drops as above and IOPs measured. Results In the 1-day study, the mean basal IOP was 23.6 ± 2.80 mmHg. Thirty minutes after instillation of the drops as described, the pressures were 23.2 ± 1.93, 22.2 ± 1.99, and 22.6 ± 2.31. The basal reading was taken at 10 am and another reading was then taken at 10.30 am. Additional eye drops were instilled at 2 and 8 pm and readings taken 30 minutes after each instillation. In the 1 week study, the basal value was 22.6 ± 2.32. After instillation of the drops as above the values were 23 ± 2.16, 22.4 ± 2.27, and 23 ± 1.94. Conclusion Administration of caffeine into the eyes of patients did not have any effect on IOP and it remained relatively unchanged. This was true in the 1-day study as well as in the 1-week study. A cumulative effect was not visible. The results therefore demonstrate that caffeine has no significant

  8. Changes in Anterior Segment Morphology and Predictors of Angle Widening after Laser Iridotomy in South Indian Eyes.

    PubMed

    Zebardast, Nazlee; Kavitha, Srinivasan; Krishnamurthy, Palaniswamy; Friedman, David S; Nongpiur, Monisha E; Aung, Tin; Quigley, Harry A; Ramulu, Pradeep Y; Venkatesh, Rengaraj

    2016-12-01

    To compare anterior segment optical coherence tomography (ASOCT) angle morphology before and after laser peripheral iridotomy (LPI) in a cohort of South Indian subjects with primary angle-closure suspect (PACS) or primary angle-closure/primary angle-closure glaucoma (PAC/PACG) and to examine baseline parameters associated with angle widening. Prospective observational study. A total of 244 subjects aged ≥30 years with PACS or PAC/PACG in at least 1 eye. The ASOCT images and angle gonioscopic grades were analyzed for all subjects at baseline and 2 weeks after LPI. Multivariable linear and logistic regression models were used to determine predictors of angle widening (change in mean angle opening distance [AOD750]) and angle opening (all 4 quadrants with trabecular meshwork [TM] visible on gonioscopy after LPI). Change in ASOCT parameters with LPI and baseline predictors of angle widening. Laser peripheral iridotomy resulted in angle widening on ASOCT with significant increases in AOD750, angle recess area, and trabecular iris surface area (P < 0.05 for all). Gonioscopically, 44.7% of all subjects had open angles in all 4 quadrants after LPI, with a greater percentage of angles open in the PACS group compared with the PAC/PACG group (52.4% vs. 36.4%; P = 0.01). In multivariable regression analyses, greater postoperative angle widening as defined by change in AOD750 was associated with shorter baseline AOD750 and axial length, and greater baseline anterior chamber depth, iris curvature, and lens vault (P ≤ 0.002 for all). Gonioscopic angle opening after LPI was more common with wider baseline angle width (modified Shaffer grade) and lower cup-to-disc ratio (P < 0.001 for both). In a South Indian population with PACS or PAC/PACG, LPI results in significant anterior chamber angle widening seen on both ASOCT and gonioscopy, although some degree of persistent iridotrabecular contact was present in approximately half of PACS eyes and approximately two thirds of PAC

  9. Removing obstacles for pavement cost reduction by examining early age opening requirements : material properties.

    DOT National Transportation Integrated Search

    2015-08-01

    The risk of cracking in a concrete pavement that is opened to traffic at early ages is related to the maximum tensile stress, , that : develops in the pavement and its relationship to the measured, age dependent, flexural strength of a beam, fr . T...

  10. Multifocal VEP and OCT findings in patients with primary open angle glaucoma: A cross-sectional study

    PubMed Central

    2012-01-01

    Bakground To evaluate objectively the anatomical and functional changes of optic nerve in eyes with primary open angle glaucoma (POAG) by the joint use of optical coherence tomography (OCT) and multifocal visual evoked potentials (mfVEP). Methods 29 eyes with open angle glaucoma and visual field defects, as well as 20 eyes of 10 age-matched control normal subjects were tested. All participants underwent a complete ophthalmological examination. Moreover, Humphrey visual field test, OCT examination and recording of mfVEP were performed. Amplitude and implicit time of mfVEP, as well as RNFL thickness were measured. Differences in density components of mfVEP and in RNFL thickness among POAG eyes and control eyes were examined using Student’s t-test. Results In glaucomatous eyes the mean Retinal Response Density (RRD) was lower than normal in ring 1, 2 and 3 of mfVEP (p < 0.0001). Specifically the mean amplitude of mfVEP in POAG eyes was estimated at 34.2 ± 17.6 nV/deg2, 6.9 ± 4.8 nV/deg2 and 2.6 ± 1.6 nV/deg2 in rings 1, 2 and 3 respectively. In contrast the mean implicit time was similar to control eyes. In addition, the mean RNFL thickness in POAG eyes was estimated at 76.8 ± 26.6 μm in the superior area, 52.1 ± 16.3 μm in the temporal area, 75.9 ± 32.5 μm in the inferior area and 58.6 ± 19.4 μm in the nasal area. There was a statistically significant difference in RNFL thickness in all peripapillary areas (p < 0.0001) between POAG eyes and controls, with superior and inferior area to present the highest decrease. Conclusions Our study shows that, although Standard Automatic Perimetry is the gold standard to evaluate glaucomatous neuropathy, the joint use of mfVEP and OCT could be useful in better monitoring glaucoma progression. PMID:22856337

  11. Prospective, non-interventional, multicenter study of the intraocular pressure-lowering effects of prostaglandin analog/prostamide-containing therapies in previously treated patients with open-angle glaucoma or ocular hypertension

    PubMed Central

    Tamçelik, Nevbahar; Izgi, Belgin; Temel, Ahmet; Yildirim, Nilgun; Okka, Mehmet; Özcan, Altan; Yüksel, Nurşen; Elgin, Ufuk; Altan, Çiğdem; Ozer, Baris

    2017-01-01

    Objective The objective of this study was to assess the intraocular pressure (IOP)-lowering efficacy, tolerability, safety, and usage patterns of prostaglandin analog/prostamide (PGA/P)-containing topical ocular hypotensives in ocular hypertension (OHT) and primary open-angle glaucoma in the Turkish clinical setting. Methods This non-interventional, multicenter study enrolled previously treated patients who failed to achieve target IOP (or experienced unacceptable adverse events [AEs]) and were prescribed a PGA/P-containing IOP-lowering agent. Treatment was initiated at baseline (V1), and patients returned at weeks 4–6 (V2) and 8–12 (V3). The primary efficacy measure was the change in IOP from baseline at V3 in each eye. The secondary measures were physician’s assessment of IOP-lowering efficacy, patients (%) reaching target IOP determined at V1, hyperemia score, physician and patient assessment of study treatment tolerability at V3, and AE frequency/severity. A subgroup analysis of patients receiving the most common study treatment was conducted. All analyses were performed using the safety population (patients who received one or more doses and had any data available). Results Of 358 enrolled patients, 60.6% had primary open-angle glaucoma, 29.9% had secondary open-angle glaucoma (protocol amendment), and 13.1% had OHT; 13 patients had multiple diagnoses. At V3, the mean IOP change from baseline was ≥−4.2 mmHg (≥21.1%). IOP met or was lower than the target in 81.7% of patients, 95% exhibited none to mild conjunctival hyperemia (most common AE), and tolerability was rated good/very good by >91.1% of patients and physicians. The results were similar in patients who received the most common study treatment, bimatoprost 0.03%/timolol 0.5% (bim/tim; n=310). Conclusion PGA/P-containing medications, including bim/tim, significantly reduced IOP in previously treated patients with open-angle glaucoma or OHT; most reached their target IOP or an IOP even lower

  12. CLINICAL RESULTS WITH THE TRABECTOME, A NOVEL SURGICAL DEVICE FOR TREATMENT OF OPEN-ANGLE GLAUCOMA

    PubMed Central

    Minckler, Don; Baerveldt, George; Ramirez, Marina Alfaro; Mosaed, Sameh; Wilson, Richard; Shaarawy, Tarek; Zack, Barend; Dustin, Laurie; Francis, Brian

    2006-01-01

    Purpose To describe treatment outcomes after Trabectome surgery in an initial series of 101 patients with open-angle glaucoma. Methods A 19-gauge microelectrosurgical device enabled ab interno removal of a strip of trabecular meshwork and inner wall of Schlemm’s canal under gonioscopic control with continual infusion and foot-pedal control of aspiration and electrosurgery. A smooth, pointed ceramic-coated insulating footplate was inserted into Schlemm’s canal to act as a guide within the canal and to protect adjacent structures from mechanical or heat injury during ablation of a 30- to 90-degree arc of angle tissue. Results Mean preoperative intraocular pressure (IOP) in the initial 101 patients was 27.6 ± 7.2 mm Hg. Thirty months postoperatively, mean IOP was 16.3 ± 3.3 mm Hg (n = 11). The mean percentage drop over the whole course of follow-up was 40%. At all times postoperatively, the absolute and percent decrease in IOP from preoperative levels were statistically significant (paired t test, P < .0001). Overall success (IOP ≤ 21 mm Hg with or without medications and no subsequent surgery) was 84%. Nine eyes subsequently underwent trabeculectomy, two others had IOP greater than 21 mm Hg in spite of resuming topical medications, and the rest of the patients either refused to resume medications or were still in the 1-month postoperative period without medications (total failure rate including trabeculectomies, 16/101 = 16%). Intraoperative reflux bleeding occurred in 100% of cases. Complications have been minimal and not vision-threatening. Conclusions The Trabectome facilitates minimally invasive and effective glaucoma surgery, which spares the conjunctiva and does not preclude subsequent standard filtering procedures. PMID:17471324

  13. Clinical results with the Trabectome, a novel surgical device for treatment of open-angle glaucoma.

    PubMed

    Minckler, Don; Baerveldt, George; Ramirez, Marina Alfaro; Mosaed, Sameh; Wilson, Richard; Shaarawy, Tarek; Zack, Barend; Dustin, Laurie; Francis, Brian

    2006-01-01

    To describe treatment outcomes after Trabectome surgery in an initial series of 101 patients with open-angle glaucoma. A 19-gauge microelectrosurgical device enabled ab interno removal of a strip of trabecular meshwork and inner wall of Schlemm's canal under gonioscopic control with continual infusion and foot-pedal control of aspiration and electrosurgery. A smooth, pointed ceramic-coated insulating footplate was inserted into Schlemm's canal to act as a guide within the canal and to protect adjacent structures from mechanical or heat injury during ablation of a 30- to 90-degree arc of angle tissue. Mean preoperative intraocular pressure (IOP) in the initial 101 patients was 27.6 +/- 7.2 mm Hg. Thirty months postoperatively, mean IOP was 16.3 +/- 3.3 mm Hg (n = 11). The mean percentage drop over the whole course of follow-up was 40%. At all times postoperatively, the absolute and percent decrease in IOP from preoperative levels were statistically significant (paired t test, P < .0001). Overall success (IOP

  14. Characteristic angles in the wetting of an angular region: deposit growth.

    PubMed

    Popov, Yuri O; Witten, Thomas A

    2003-09-01

    Solids dispersed in a drying drop migrate to the (pinned) contact line. This migration is caused by outward flows driven by the loss of the solvent due to evaporation and by geometrical constraint that the drop maintains an equilibrium surface shape with a fixed boundary. Here, in continuation of our earlier paper, we theoretically investigate the evaporation rate, the flow field, and the rate of growth of the deposit patterns in a drop over an angular sector on a plane substrate. Asymptotic power laws near the vertex (as distance to the vertex goes to zero) are obtained. A hydrodynamic model of fluid flow near the singularity of the vertex is developed and the velocity field is obtained. The rate of the deposit growth near the contact line is found in two time regimes. The deposited mass falls off as a weak power gamma of distance close to the vertex and as a stronger power beta of distance further from the vertex. The power gamma depends only slightly on the opening angle alpha and stays roughly between -1/3 and 0. The power beta varies from -1 to 0 as the opening angle increases from 0 degrees to 180 degrees. At a given distance from the vertex, the deposited mass grows faster and faster with time, with the greatest increase in the growth rate occurring at the early stages of the drying process.

  15. [The effectiveness of endonasal electrophoresis of neuroprotective agents used in the rehabilitative treatment of the patients presenting with primary open angle glaucoma].

    PubMed

    Nazarova, G A; Konchugova, T V; Iurova, O V; Sichinava, N V; Turova, E A; Rassulova, M A; Morozova, N E

    2013-01-01

    The objective of the present study was to estimate the effectiveness of the peptide drug cortexin used to treat primary open angle glaucoma. It was shown that endonasal electrophoresis of cortexin resulted in more pronounced positive changes in the dynamics of clinical, functional, perimetric, and electrophysiological characteristics compared with intramuscular administration of the same drug to the patients of the control group. This difference was apparent both immediately after the termination of the treatment and during the long-term follow-up.

  16. [Treatment of open tile type C pelvic fractures by open reduction and internal fixation through anterior and posterior approaches at early stage].

    PubMed

    Li, Baichuan

    2014-05-01

    To explore the effectiveness of open reduction and internal fixation through anterior and posterior approaches in treatment of open Tile type C pelvic fractures at early stage. Between January 2009 and April 2012, 12 patients with open Tile C pelvic fractures were treated. There were 7 males and 5 females, aged 6-53 years (median, 31 years). Of 12 cases, 4 were classified as Tile type C1, 6 as Tile type C2, and 2 as Tile type C3; 5 were rated as Gustilo type II and 7 as Gustilo type III. The injury severity score was 18-57 (mean, 37.2). The interval of injury and admission ranged from 15 minutes to 3 days (median, 50 minutes). The debridement and external fixation were performed at first stage; then open reduction and internal fixation were used through anterior approach (reconstruction plate) and posterior approach (cannulated lag screws). The vacuum sealing drainage was performed during treatment until the wounds healed. Delayed healing of incison was obtained in 12 cases because of wound infection. Anatomical reduction or approximate anatomical reduction was achieved in all 12 cases. The patients were followed up 3-39 months (median, 18 months). No loosening of internal fixation or fracture displacement was observed during follow-up. The fracture healing time was 7-13 weeks (mean, 9.7 weeks). At last follow-up, according to the Matta standard, the outcome was excellent in 10 cases and good in 2 cases; according to Majeed score, the results were excellent in 9 cases, good in 1, and poor in 2. Early internal fixation operation of open Tile type C pelvic fractures can effectively restore the pelvic anatomical structure and stability, reduce the complication, and achieve satisfactory effectiveness.

  17. Enhancing Student Services at Lorain County Community College: Early Results from the Opening Doors Demonstration in Ohio

    ERIC Educational Resources Information Center

    Scrivener, Susan; Au, Jenny

    2007-01-01

    In 2003, MDRC and a consortium of funders launched the Opening Doors demonstration to test reforms in six community colleges aimed at helping students stay in school and earn credentials. This report presents early results from the Opening Doors program at Lorain County Community College in Elyria, Ohio. The program provided intensive advising and…

  18. Assessment of narrow angles by gonioscopy, Van Herick method and anterior segment optical coherence tomography.

    PubMed

    Park, Seong Bae; Sung, Kyung Rim; Kang, Sung Yung; Jo, Jung Woo; Lee, Kyoung Sub; Kook, Michael S

    2011-07-01

    To evaluate anterior chamber (AC) angles using gonioscopy, Van Herick technique and anterior segment optical coherence tomography (AS-OCT). One hundred forty-eight consecutive subjects were enrolled. The agreement between any two of three diagnostic methods, gonioscopy, AS-OCT and Van Herick, was calculated in narrow-angle patients. The area under receiver-operating characteristic curves (AUC) for discriminating between narrow and open angles determined by gonioscopy was calculated in all participants for AS-OCT parameter angle opening distance (AOD), angle recess area, trabecular iris surface area and anterior chamber depth (ACD). As a subgroup analysis, capability of AS-OCT parameters for detecting angle closure defined by AS-OCT was assessed in narrow-angle patients. The agreement between the Van Herick method and gonioscopy in detecting angle closure was excellent in narrow angles (κ = 0.80, temporal; κ = 0.82, nasal). However, agreement between gonioscopy and AS-OCT and between the Van Herick method and AS-OCT was poor (κ = 0.11-0.16). Discrimination capability of AS-OCT parameters between open and narrow angles determined by gonioscopy was excellent for all AS-OCT parameters (AUC, temporal: AOD500 = 0.96, nasal: AOD500 = 0.99). The AUCs for detecting angle closure defined by AS-OCT image in narrow angle subjects was good for all AS-OCT parameters (AUC, 0.80-0.94) except for ACD (temporal: ACD = 0.70, nasal: ACD = 0.63). Assessment of narrow angles by gonioscopy and the Van Herick technique showed good agreement, but both measurements revealed poor agreement with AS-OCT. The angle closure detection capability of AS-OCT parameters was excellent; however, it was slightly lower in ACD.

  19. Mapping of a gene for autosomal dominant juvenile-onset open-angle glaucoma to chromosome 1 q

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richards, J.E.; Lichter, P.R.; Torrez, D.

    1994-01-01

    A large Caucasian family is presented, in which a juvenile-onset form of open-angle glaucoma is transmitted in an autosomal dominant fashion. Sixteen affected family members were identified from 31 at-risk individuals descended from the affected founder. Affected patients developed high intraocular pressures (sometimes >40 mm Hg) within the first 2 decades of life. Linkage analysis between the disease phenotype and 12 microsatellite repeat markers located on chromosome 1 q gave a maximum lod score of 8.38 at a recombination fraction of zero for marker D1S210. Analysis of recombinant haplotypes suggests a total inclusion region of about 14 cM between markersmore » D1S194 and D1S218 at 1q21-q31. This represents the second juvenile-glaucoma family, in which the disease has been mapped to the long arm of chromosome 1. 57 refs., 2 figs., 3 tabs.« less

  20. Evaluation of anterior chamber angle under dark and light conditions in angle closure glaucoma: An anterior segment OCT study.

    PubMed

    Masoodi, Habibeh; Jafarzadehpur, Ebrahim; Esmaeili, Alireza; Abolbashari, Fereshteh; Ahmadi Hosseini, Seyed Mahdi

    2014-08-01

    To evaluate changes of nasal and temporal anterior chamber angle (ACA) in subjects with angle closure glaucoma using Spectralis AS-OCT (SAS-OCT) under dark and light conditions. Based on dark-room gonioscopy, 24 subjects with open angles and 86 with narrow angles participated in this study. The nasal and temporal angle opening distance at 500 μm anterior to the scleral spur (AOD500), nasal and temporal ACA were measured using SAS-OCT in light and dark conditions. In 2 groups, ACA and AOD500 in nasal and temporal quadrants were significantly greater in light compared to dark (all with p=0.000). The AOD500 and ACA were significantly higher in nasal than temporal in measured conditions for 2 groups except the ACA and AOD500 of normal group measured in light. The difference between nasal and temporal in dark (29.07 ± 65.71 μm for AOD500 and 5.7 ± 4.07° for ACA) was greater than light (24.86 ± 79.85 μm for AOD500 and 2.09 ± 7.21° for ACA) condition. But the difference was only significant for ACA (p=0.000). The correlation analysis showed a negative correlation between AOD500 and pupil diameter in temporal and nasal quadrants (both with p=0.000). While temporal AOD500 difference correlated with spherical equivalent, temporal and asal gonioscopy, nasal AOD correlated with IOP, temporal and nasal gonioscopy. Clinically important changes in ACA structure could be detected with SAS-OCT in nasal and temporal quadrants under different illumination intensity. The results could help in improvement of examination condition for better and more accurate assessment of individuals with angle closure glaucoma. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  1. Some Characteristics of Fuel Sprays from Open Nozzles

    NASA Technical Reports Server (NTRS)

    Rothrock, A M; Lee, D W

    1930-01-01

    The penetration and cone-angle of fuel sprays from open nozzles were recorded with the NACA Spray Photography Equipment. The results show that for injection systems in which the rate of pressure rise at the discharge orifice is high, open nozzles give spray-tip velocities and penetrations which compare favorably with those of closed nozzles. The spray cone-angle was the same for all tests, although open nozzles having different orifice diameters were used, and one nozzle was used both as an open and as a closed nozzle. In designing a fuel system using open nozzles, particular care must be taken to avoid air pockets. The check valve should be placed close to the discharge orifice.

  2. Structural brain alterations in primary open angle glaucoma: a 3T MRI study

    PubMed Central

    Wang, Jieqiong; Li, Ting; Sabel, Bernhard A.; Chen, Zhiqiang; Wen, Hongwei; Li, Jianhong; Xie, Xiaobin; Yang, Diya; Chen, Weiwei; Wang, Ningli; Xian, Junfang; He, Huiguang

    2016-01-01

    Glaucoma is not only an eye disease but is also associated with degeneration of brain structures. We now investigated the pattern of visual and non-visual brain structural changes in 25 primary open angle glaucoma (POAG) patients and 25 age-gender-matched normal controls using T1-weighted imaging. MRI images were subjected to volume-based analysis (VBA) and surface-based analysis (SBA) in the whole brain as well as ROI-based analysis of the lateral geniculate nucleus (LGN), visual cortex (V1/2), amygdala and hippocampus. While VBA showed no significant differences in the gray matter volumes of patients, SBA revealed significantly reduced cortical thickness in the right frontal pole and ROI-based analysis volume shrinkage in LGN bilaterally, right V1 and left amygdala. Structural abnormalities were correlated with clinical parameters in a subset of the patients revealing that the left LGN volume was negatively correlated with bilateral cup-to-disk ratio (CDR), the right LGN volume was positively correlated with the mean deviation of the right visual hemifield, and the right V1 cortical thickness was negatively correlated with the right CDR in glaucoma. These results demonstrate that POAG affects both vision-related structures and non-visual cortical regions. Moreover, alterations of the brain visual structures reflect the clinical severity of glaucoma. PMID:26743811

  3. High prevalence of anxiety and depression in patients with primary open-angle glaucoma.

    PubMed

    Mabuchi, Fumihiko; Yoshimura, Kimio; Kashiwagi, Kenji; Shioe, Kunihiko; Yamagata, Zentaro; Kanba, Shigenobu; Iijima, Hiroyuki; Tsukahara, Shigeo

    2008-01-01

    To assess anxiety and depression in patients with primary open-angle glaucoma (POAG). Multicenter prospective case-control study. Two hundred thirty patients with POAG and 230 sex-matched and age-matched reference subjects with no chronic ocular conditions except cataracts. Anxiety and depression were evaluated using Hospital Anxiety and Depression Scale (HADS) questionnaire, which consists of 2 subscales with ranges of 0 to 21, representing anxiety (HADS-A) and depression (HADS-D). The prevalence of POAG patients with anxiety (a score of more than 10 on the HADS-A) or depression (a score of more than 10 on the HADS-D) was compared with that in the reference subjects. The prevalence of patients with depression was compared between the POAG patients with and without current beta-blocker eye drops. The prevalence (13.0%) of POAG patients with anxiety was significantly higher (P=0.030) than in the reference subjects (7.0%). The prevalence (10.9%) of POAG patients with depression was significantly higher (P=0.026) than in the reference subjects (5.2%). Between the POAG patients with and without beta-blocker eye-drops, no significant difference (P=0.93) in the prevalence of depression was noted. POAG was related to anxiety and depression. No significant relationship between the use of beta-blocker eye-drops and depression was noted.

  4. Anterior chamber angle assessment using gonioscopy and ultrasound biomicroscopy.

    PubMed

    Narayanaswamy, Arun; Vijaya, Lingam; Shantha, B; Baskaran, Mani; Sathidevi, A V; Baluswamy, Sukumar

    2004-01-01

    Comparison of anterior chamber angle measurements using ultrasound biomicroscopy (UBM) and gonioscopy. Five hundred subjects were evaluated for grading of angle width by the Shaffer method. UBM was done in the same group to document angle width, angle opening distance (AOD 500), and anterior chamber depth. Biometric parameters were documented in all subjects. UBM and gonioscopic findings were compared. A study was conducted in 282 men and 218 women with a mean age of 57.32 +/- 12.48 years. Gonioscopic grading was used to segregate occludable (slit-like, grades 1 and 2) from nonoccludable (grades 3 and 4) angles. Subjective assessment by gonioscopy resulted in an overestimation of angle width within the occludable group when compared with values obtained by UBM. This did not affect the segregation of occludable versus nonoccludable angles by gonioscopy. Biometric parameters in eyes with occludable angles were significantly lower in comparison with eyes with nonoccludable angles, except for lens thickness. AOD 500 correlated well with angle width. We concluded that clinical segregation into occludable and nonoccludable angles by an experienced observer using gonioscopy is fairly accurate. However, UBM is required for objective quantification of angles, and AOD 500 can be a reliable and standard parameter to grade angle width.

  5. Resident compliance with the american academy of ophthalmology preferred practice pattern guidelines for primary open-angle glaucoma.

    PubMed

    Ong, Sally S; Sanka, Krishna; Mettu, Priyatham S; Brosnan, Thomas M; Stinnett, Sandra S; Lee, Paul P; Challa, Pratap

    2013-12-01

    To examine resident adherence to preferred practice pattern (PPP) guidelines set up by the American Academy of Ophthalmology for follow-up care of primary open-angle glaucoma (POAG) patients. Retrospective chart review. One hundred three charts were selected for analysis from all patients with an International Classification of Diseases, Ninth Revision, code of open-angle glaucoma or its related entities who underwent a follow-up evaluation between July 2, 2003, and December 15, 2004, at the resident ophthalmology clinic in the Durham Veteran Affairs Medical Center. Follow-up visits of POAG patients were evaluated for documentation of 19 elements in accordance to PPP guidelines. Compliance rates for the 19 elements of PPP guidelines first were averaged in all charts, and then were averaged per resident and were compared among 8 residents between their first and second years of residency. The overall mean compliance rate for all 19 elements was 82.6% for all charts (n = 103), 78.8% for first-year residents, and 81.7% for second-year residents. The increase from first to second year of residency was not significant (P>0.05). Documentation rates were high (>90%) for 14 elements, including all components of the physical examination and follow-up as well as most components of the examination history and management plan. Residents documented adjusting target intraocular pressure downward, local or systemic problems with medications, and impact of visual function on daily living approximately 50% to 80% of the time. Documentation rates for components of patient education were the lowest, between 5% and 16% in all charts. Residents' compliance with PPP guidelines for a POAG follow-up visit was very high for most elements, but documentation rates for components of patient education were poor. Adherence rates to PPP guidelines can be used as a tool to evaluate and improve resident performance during training. However, further studies are needed to establish the advantages of

  6. Pre-dawn stomatal opening does not substantially enhance early-morning photosynthesis in Helianthus annuus.

    PubMed

    Auchincloss, Lisa; Easlon, Hsien M; Levine, Diedre; Donovan, Lisa; Richards, James H

    2014-06-01

    Most C3 plant species have partially open stomata during the night especially in the 3-5 h before dawn. This pre-dawn stomatal opening has been hypothesized to enhance early-morning photosynthesis (A) by reducing diffusion limitations to CO2 at dawn. We tested this hypothesis in cultivated Helianthus annuus using whole-shoot gas exchange, leaf level gas exchange and modelling approaches. One hour pre-dawn low-humidity treatments were used to reduce pre-dawn stomatal conductance (g). At the whole-shoot level, a difference of pre-dawn g (0.40 versus 0.17 mol m(-2) s(-1)) did not significantly affect A during the first hour after dawn. Shorter term effects were investigated with leaf level gas exchange measurements and a difference of pre-dawn g (0.10 versus 0.04 mol m(-2) s(-1)) affected g and A for only 5 min after dawn. The potential effects of a wider range of stomatal apertures were explored with an empirical model of the relationship between A and intercellular CO2 concentration during the half-hour after dawn. Modelling results demonstrated that even extremely low pre-dawn stomatal conductance values have only a minimal effect on early-morning A for a few minutes after dawn. Thus, we found no evidence that pre-dawn stomatal opening enhances A.

  7. Histological findings of failed gold micro shunts in primary open-angle glaucoma.

    PubMed

    Agnifili, Luca; Costagliola, Ciro; Figus, Michele; Iezzi, Giovanna; Piattelli, Adriano; Carpineto, Paolo; Mastropasqua, Rodolfo; Nardi, Marco; Mastropasqua, Leonardo

    2012-01-01

    To describe the histological features of failed gold micro shunts (GMS) in unsuccessful implantations for refractory primary open-angle glaucoma (POAG). This was an interventional case series study. Five eyes of five glaucomatous patients with unsuccessful GMS implantation underwent shunt removal. Each device was sectioned into three portions: proximal or anterior chamber (AC) portion, middle or scleral portion and distal or suprachoroidal (SC) portion. The histological analysis was performed throughout the whole extent of the shunt, describing both the inner spaces and the outer surface. At the moment of removal all devices were correctly located into the SC space and in AC, with the exception of a case presenting corneal endothelial contact. The mean intra-ocular pressure before GMS removal was 30.4 ± 5.3 mmHg, and the mean time of GMS removal after implantation was 6.8 ± 2.5 months. No significant histological differences were documented among the five analyzed devices. The main feature was the presence of a thick connective capsule-like reaction surrounding both the proximal and distal ends and invading the posterior and anterior grid holes, whereas a more loosely arranged connective tissue was observed within the inner channels. Signs of surface fibrosis of the middle-scleral portion and inflammatory cell infiltration of the device were not documented in any of the cases. Failed GMS implantations presented connective tissue filling all the inner spaces and creating a thick fibrotic capsule surrounding the ends of the device. This modification isolated the GMS from the AC and SC space, impeding aqueous flows throughout the shunt.

  8. Unaltered myocilin expression in the blood of primary open angle glaucoma patients

    PubMed Central

    Azad, Taif Anwar; Spaeth, George L.; Myers, Jonathan; Katz, L. Jay; Moster, Marlene; Bosley, Thomas M.

    2012-01-01

    Purpose To investigate the expression of the myocilin gene (MYOC) in the blood of primary open angle glaucoma (POAG) patients to determine if altered systemic expression is playing a role. Methods Patients (n=47) were eligible for inclusion if they met standard clinical criteria for POAG. Control subjects (n=27) were recruited who were free from glaucoma by examination. RNA was extracted from leukocytes of patients and controls and converted to cDNA by reverse transcriptase enzyme, and quantitative PCR was used to assess expression levels of MYOC and the house keeping gene β-globulin (HBB). The ratio of MYOC expression to HBB expression for POAG patients was compared to that of controls and to clinical characteristics of POAG patients. Results Mean gene expression values were statistically similar in POAG patients and controls for both MYOC (p≤0.55) and HBB (p≤0.48). MYOC/HBB ratios were also statistically indistinguishable between POAG patients and controls (p≤0.90). MYOC/HBB ratios were not significantly associated with age, sex, or ethnicity of patients within the POAG group. Similarly, MYOC/HBB ratios were not significantly associated with clinical parameters related to POAG severity, including maximum intraocular pressure, vertical cup-to-disk ratio, static perimetry mean deviation, or static perimetry pattern standard deviation. Conclusions MYOC expression is not altered in the blood of POAG patients, unlike MYOC expression in trabecular meshwork (TM) cultures. These results suggests that MYOC expression is not altered systemically but rather that MYOC expression may contribute to POAG pathogenesis in specific tissues such as TM. PMID:22550394

  9. Two-phase opening of Andaman Sea: a new seismotectonic insight

    NASA Astrophysics Data System (ADS)

    Khan, P. K.; Chakraborty, Partha Pratim

    2005-01-01

    High-resolution reconstruction of Benioff zone depth-dip angle trajectory for Burma-Java subduction margin between 2° and 17°N Lat. reveals two major episodes of plate geometry change expressed as abrupt deviation in subduction angle. Estimation of effective rate of subduction in different time slices (and then length of subducted slab) allowed drawing of isochrones in Ma interval through these trajectories for the time period 5-12 Ma. With these isochrones, the deformation events on the subducting Indian plate are constrained in time as of 4-5 and 11 Ma old. This well-constrained time connotation offered scope for the correlation of slab deformation events with the well-established two-phase opening history of the Andaman Sea. While the 11 Ma event recorded from southern part of the study area is correlated with early stretching and rifting phase, the 4-5 Ma event is interpreted as major forcing behind the spreading phase of the Andaman Sea. Systematic spatio-temporal evaluation of Indian plate obliquity on the Andaman Sea evolution shows its definite control on the early rifting phase, initiated towards south near northwest Sumatra. The much young spreading phase recorded towards north of 7° Lat. is possibly the result of late Miocene-Pliocene trench retreat and follow-up transcurrent movement (along Sagaing and Sumatran fault system) with NW-SE pull-apart extension. Nonconformity between plate shape and subduction margin geometry is interpreted as the causative force behind Mid-Miocene intraplate extension and tearing. Enhanced stretching in the overriding plate consequently caused active forearc subsidence, recorded all along this plate margin. Initial phase of the Andaman Sea opening presumably remains concealed in this early-middle Miocene forearc subsidence history. The late Miocene-Pliocene pull-apart opening and spreading was possibly initiated near the western part of the Mergui-Sumatra region and propagated northward in subsequent period. A temporary

  10. Early Childhood Open-Mindedness: An Investigation into Preservice Teachers' Capacity to Address Controversial Issues

    ERIC Educational Resources Information Center

    Bautista, Nazan; Misco, Thomas; Quaye, Stephen John

    2018-01-01

    We investigated the characteristics of early childhood education (ECE) preservice teachers (PSTs) who were identified as closed minded and their capacity to deal with controversial issues. We define open-mindedness as the willingness to consider experiences, beliefs, values, and perspectives that differ from one's own. First, we used quantitative…

  11. Hypothyroidism as a risk factor for open angle glaucoma: A systematic review and meta-analysis

    PubMed Central

    Liu, Yue; Zheng, Guangying

    2017-01-01

    Purpose The relationship between hypothyroidism and primary open angle glaucoma (POAG) has attracted intense interest recently, but the reported results have been controversial. This meta-analysis was carried out to determine the association between hypothyroidism and POAG. Methods The literature was identified from three databases (Web of Science, Embase, and PubMed). The meta-analyses were performed using random-effects models, with results reported as adjusted odds ratios (ORs) with 95% confidence intervals (CI 95%). Results A total of 11 studies meeting the inclusion criteria were included in the final meta-analysis. The pooled OR based on 11 risk estimates showed a statistically significant increased risk of POAG prevalence among individuals with hypothyroidism (OR = 1.64, 95% CI = 1.27–2.13). Substantial heterogeneity among these studies was detected (P < 0.001; I2 = 83.2%). Sub-group analysis revealed that the cohort studies and case–control studies showed a significant association between hypothyroidism and POAG, which was not observed in cross-sectional studies. There was no significant publication bias in this study. Conclusions The findings of this meta-analysis indicate that individuals with hypothyroidism have an increased risk of developing POAG. PMID:29069095

  12. Common variants near ABCA1, AFAP1 and GMDS confer risk of primary open-angle glaucoma

    PubMed Central

    Fogarty, Rhys; Sharma, Shiwani; Hewitt, Alex W.; Martin, Sarah; Law, Matthew H.; Cremin, Katie; Bailey, Jessica N. Cooke; Loomis, Stephanie J.; Pasquale, Louis R.; Haines, Jonathan L.; Hauser, Michael A.; Viswanathan, Ananth C.; McGuffin, Peter; Topouzis, Fotis; Foster, Paul J.; Graham, Stuart L; Casson, Robert J; Chehade, Mark; White, Andrew J; Zhou, Tiger; Souzeau, Emmanuelle; Landers, John; Fitzgerald, Jude T; Klebe, Sonja; Ruddle, Jonathan B; Goldberg, Ivan; Healey, Paul R; Mills, Richard A.; Wang, Jie Jin; Montgomery, Grant W.; Martin, Nicholas G.; Radford-Smith, Graham; Whiteman, David C.; Brown, Matthew A.; Wiggs, Janey L.; Mackey, David A; Mitchell, Paul; MacGregor, Stuart; Craig, Jamie E.

    2014-01-01

    Primary open-angle glaucoma (POAG) is a major cause of irreversible blindness worldwide. We performed a genome-wide association study in an Australian discovery cohort comprising 1,155 advanced POAG cases and 1,992 controls. Association of the top SNPs from the discovery stage was investigated in two Australian replication cohorts (total 932 cases, 6,862 controls) and two US replication cohorts (total 2,616 cases, 2,634 controls). Meta-analysis of all cohorts revealed three novel loci associated with development of POAG. These loci are located upstream of ABCA1 (rs2472493 [G] OR=1.31, P= 2.1 × 10−19), within AFAP1 (rs4619890 [G] OR=1.20, P= 7.0 × 10−10) and within GMDS (rs11969985 [G] OR=1.31, and P= 7.7 × 10−10). Using RT-PCR and immunolabelling, we also showed that these genes are expressed within human retina, optic nerve and trabecular meshwork and that ABCA1 and AFAP1 are also expressed in retinal ganglion cells. PMID:25173105

  13. Open angle glaucoma in a case of Type IV Ehler Danlos syndrome: A rarely reported association

    PubMed Central

    Mitra, Arijit; Ramakrishnan, R.; Kader, Mohideen Abdul

    2014-01-01

    A 26-year-old male presented to us with defective vision in the left eye. He had best corrected visual acuity (BCVA) of hand movement (HM) in right eye and 6/9 in left eye. He had ptosis with ectropion in both eyes and relative afferent pupillary defect (RAPD) in right eye. Intraocular pressure (IOP) was 46 and 44 mmHg in right and left eye, respectively. Fundus showed glaucomatous optic atrophy (GOA) in right eye and cup disc ratio (CDR) of 0.75 with bipolar rim thinning in left eye. Systemic examination showed hyperextensible skin and joints, acrogeria, hypodontia, high arched palate, and varicose veins. He gave history of easy bruising and tendency to fall and history of intestinal rupture 5 years ago for which he had undergone surgery. He was diagnosed as a case of Type IV Ehler-Danlos syndrome (EDS) with open angle glaucoma. He underwent trabeculectomy in both eyes. This is a rare case that shows glaucoma in a patient of EDS Type IV. Very few such cases have been reported in literature. PMID:25230966

  14. Open angle glaucoma in a case of Type IV Ehler Danlos syndrome: a rarely reported association.

    PubMed

    Mitra, Arijit; Ramakrishnan, R; Kader, Mohideen Abdul

    2014-08-01

    A 26-year-old male presented to us with defective vision in the left eye. He had best corrected visual acuity (BCVA) of hand movement (HM) in right eye and 6/9 in left eye. He had ptosis with ectropion in both eyes and relative afferent pupillary defect (RAPD) in right eye. Intraocular pressure (IOP) was 46 and 44 mmHg in right and left eye, respectively. Fundus showed glaucomatous optic atrophy (GOA) in right eye and cup disc ratio (CDR) of 0.75 with bipolar rim thinning in left eye. Systemic examination showed hyperextensible skin and joints, acrogeria, hypodontia, high arched palate, and varicose veins. He gave history of easy bruising and tendency to fall and history of intestinal rupture 5 years ago for which he had undergone surgery. He was diagnosed as a case of Type IV Ehler-Danlos syndrome (EDS) with open angle glaucoma. He underwent trabeculectomy in both eyes. This is a rare case that shows glaucoma in a patient of EDS Type IV. Very few such cases have been reported in literature.

  15. Serotonin levels in aqueous humor of patients with primary open-angle glaucoma.

    PubMed

    Zanon-Moreno, V; Melo, P; Mendes-Pinto, M M; Alves, C J; Garcia-Medina, J J; Vinuesa-Silva, I; Moreno-Nadal, M A; Pinazo-Duran, M D

    2008-01-01

    Glaucoma is an optic neuropathy characterized by a high intraocular pressure (IOP), alterations in optic nerve head, and loss of visual field that could lead to bilateral blindness. Serotonin (5-HT) is a biogenic monoamine that is synthesized from hydroxylation of tryptophan and acts by three ways, dissemination, metabolism, and reuptake in synaptic cleft through specific systems of the membrane. The purpose of this study is to evaluate the 5-HT and 5-HIAA (5-hydroxiindolacetic acid) levels in the aqueous humor of patients with primary open-angle glaucoma (POAG). We performed a case-control study, and the patients recruited were classified into two groups, 1) 30 patients with POAG (GG) and 2) 30 patients with cataracts (CG), who acted as the controls. Aqueous humor samples of each patient were obtained by paracentesis at the beginning of the surgical procedures. 5-HT and 5-HIAA levels were determined by high performance liquid chromatography (HPLC) with electrochemical detection. There were no statistical differences between age (71.3 +/- 7.2 years in GG, 73.5 +/- 9.0 years in CG; p=0.2581) or gender (sex ratio 0.765 in GG and 0.667 in CG). 5-HT levels were lower in GG, but this difference was not significant (p=0.820). We observed a statistically significant higher level of 5-HIAA in GG (p=0.001). The 5-HT turnover (5-HIAA/5-HT) were higher in GG than in CG (p<0.05), but the difference was not significant (p=0.598). The level of 5-HT was lower in GG patients, and the level of 5-HIAA was higher in GG patients than in CG patients.

  16. Risk Factors for Primary Open Angle Glaucoma (POAG) Progression: A Study Ruled in Torino

    PubMed Central

    Actis, A.G.; Versino, E.; Brogliatti, B.; Rolle, T.

    2016-01-01

    Purpose: Aim of this retrospective, observational study is to describe features of a population sample, affected by primary open angle glaucoma (POAG) in order to evaluate damage progression on the basis of the emerged individual risk factors. Methods: We included 190 caucasian patients (377 eyes), evaluating relationship between individual risk factors (explicative variables) and MD (Mean Deviation) of standard automated perimetry. We also considered the dependent variable NFI (Neural Fiber Index) of GDx scanning laser polarimetry. Progression has been evaluated through a statistic General Linear Model on four follow up steps (mean follow up 79 months). Results: Factors reaching statistical significance, determining a worsening of the MD variable, are: age (P<0.0001), intraocular pressure (IOP) at follow up (P < 0.0001), female gender (P<0.0001), hypertension (P< 0.0001) and familiarity (P = 0.0006). Factors reaching statistical significance, determining a worsening of the NFI variable, are only IOP at follow up (P = 0.0159) and depression (P = 0.0104). Conclusion: Results of this study confirm and enforce data coming from most recent studies: IOP remains the main risk factor for glaucoma assess and progression; age and familiarity are great risk factors as underlined in the last decades; female sex can be an important risk factors as emerged only in the last years; arterial hypertension should always be evaluated in timing of our clinic follow up. PMID:27347249

  17. Blood Pressure, Perfusion Pressure, and Open-Angle Glaucoma: The Los Angeles Latino Eye Study

    PubMed Central

    Memarzadeh, Farnaz; Ying-Lai, Mei; Chung, Jessica; Azen, Stanley P.

    2010-01-01

    Purpose. To examine the cross-sectional relationship between blood pressure, perfusion pressure, and prevalence of open angle glaucoma (OAG) in an adult Latino population. Methods. Participants aged 40 years and older (N = 6130) from the Los Angeles Latino Eye Study (LALES), a large, population-based study of self-identified adult Latinos, underwent an interviewer-administered questionnaire and a complete ocular and clinical examination. Logistic regression was used to evaluate the covariate-adjusted association of OAG with systolic, diastolic, and mean blood pressures and perfusion pressures. Covariates included age, intraocular pressure, history of glaucoma treatment including medications and surgery, and history of blood pressure and treatment of blood pressure including use of medications. Results. Low systolic (odds ratio [OR] = 2.5), diastolic (OR = 1.9), and mean (OR = 3.6) perfusion pressures and low diastolic blood pressure (OR = 1.9) were associated with a higher prevalence of OAG in LALES participants. Higher systolic blood pressure and mean arterial blood pressure were associated with a higher prevalence of OAG. There was no relationship between the prevalence of OAG and the presence of a history of cardiovascular disease. Conclusions. Low diastolic, systolic and mean perfusion pressures, low diastolic blood pressure, and high systolic and mean arterial blood pressures are associated with a higher prevalence of OAG in adult Latinos. PMID:20089880

  18. Localization of a locus (GLC1B) for adult-onset primary open angle glaucoma to the 2cen-q13 region

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoilova, D.; Trifan, O.C.; Sarfarazi, M.

    1996-08-15

    Primary open angle glaucoma (GLC1) is a common ocular disorder with a characteristic degeneration of the optic nerve and visual field defects that is often associated with an elevated intraocular pressure. The severe but rare juvenile-onset type has previously been mapped to 1q21-q31, and its genetic heterogeneity has been established. Herein, we present a new locus (GLC1B) for one form of GLC1 on chromosome 2cen-q13 with a clinical presentation of low to moderate intraocular pressure, onset in late 40s, and a good response to medical treatment. Two-point and haplotype analyses of affected and unaffected meioses in six families provided maximummore » linkage information with D2S417, GATA112EO3, D2S113, D2S373, and D2S274 (lod scores ranging from 3.11 to 6.48) within a region of 8.5 cM that is flanked by D2S2161 and D2S2264. Analysis of affected meioses alone revealed no recombination with an additional two markers (D2S2264 and D2S135) in a region of 11.2 cM that is flanked by D2S2161 and D2S176. Analysis of unaffected meioses identified only one healthy 86-year-old male who has inherited the entire affected haplotype and, hence, is a gene carrier for this condition. Eight additional families with similar and/or different clinical presentation did not show any linkage to this region and, therefore, provided evidence for genetic heterogeneity of adult-onset primary open angle glaucoma. 63 refs., 2 figs., 2 tabs.« less

  19. [Studying the association between genetic polymorphism of growth factors and the development of primary open-angle glaucoma].

    PubMed

    Kirilenko, M Yu; Tikunova, E V; Sirotina, S S; Polonikov, A V; Bushueva, O Yu; Churnosov, M I

    Primary open-angle glaucoma (POAG) is a multifactorial disease, etiopathogenesis of which largely depends on growth factors. Possessing a variety of medical and biological effects, these cytokines may influence the development and progression of POAG. to reveal the role of genetic polymorphisms of growth factors in predisposition to developing POAG that is refractory to local hypotensive therapy. The object of the study were 162 patients with stage II-III POAG, in whom local hypotensive therapy was inefficient, 90 patients with stage II-III POAG well controlled on local hypotensive therapy, and 191 controls. The material for the study was venous blood taken from the cubital vein of a proband. Isolation of genomic DNA was performed by phenol-chloroform extraction. Analysis of genetic polymorphisms of growth factors was performed through allelic discrimination. For that, synthesis of DNA was carried out via polymerase chain reaction (PCR). It is found that the T IGFR-1 genetic variant (OR=1.34) and a combination of the C VEGF-A and T IGFR-1 genetic variants (OR=1.90) are risk factors of developing POAG that is refractory to local hypotensive therapy. A statistical model for predicting such a risk has been proposed that includes: VEGF-A с.-958C>T genetic marker (rs 833,061), age, concomitant non-inflammatory ocular diseases, microvascular changes in the conjunctiva, the degree of pigmentation of the angle of the anterior chamber, and pseudoexfoliative syndrome. Recognition accuracy of the model is 90.42%. The T IGFR-1 genetic variant and a combination of the C VEGF-A and T IGFR-1 genetic variants increase the risk of developing POAG that is refractory to local hypotensive therapy.

  20. Change in Visual Field Progression Following Treatment Escalation in Primary Open-angle Glaucoma.

    PubMed

    Aptel, Florent; Bron, Alain M; Lachkar, Yves; Schweitzer, Cédric

    2017-10-01

    To evaluate the effect of treatment escalation on the rate of visual field progression in patients with primary open-angle glaucoma (POAG). Multicenter database study. We reviewed the electronic records of 171 patients with POAG under medical hypotensive treatment who underwent 5 consecutive visits 6 months apart before and after medical treatment escalation or additive laser trabeculoplasty. We calculated the rate of visual field progression (mean deviation change per year) before and after treatment escalation. The mean duration of follow-up was 5.1±0.5 years and the mean number of visual field examinations was 10.2±0.2. In 139 eyes with medical treatment escalation, the rate of progression was significantly reduced [from -0.57 to -0.29 dB/y; P=0.022; intraocular pressure (IOP) reduction 11.1%]. In detail, the rate of progression was significantly reduced after escalation from mono to dual therapy, dual to triple therapy, and from mono to triple therapy (-0.35 to -0.24 dB/y, P=0.018; -1.01 to -0.48 dB/y, P=0.038; -1.04 to -0.35 dB/y, P=0.020, respectively). In 32 eyes with additive laser trabeculoplasty, the rate of progression was significantly reduced (-0.60 to -0.24 dB/y; P=0.014; IOP reduction 9.4%). Medical treatment escalation or additive laser trabeculoplasty significantly reduced the rate of visual field progression in POAG. Larger IOP reduction has a greater probability of reducing glaucoma progression.

  1. Latanoprostene Bunod 0.024% in Subjects With Open-angle Glaucoma or Ocular Hypertension: Pooled Phase 3 Study Findings.

    PubMed

    Weinreb, Robert N; Liebmann, Jeffrey M; Martin, Keith R; Kaufman, Paul L; Vittitow, Jason L

    2018-01-01

    To compare the diurnal intraocular pressure (IOP)-lowering effect of latanoprostene bunod (LBN) 0.024% with timolol maleate 0.5% in subjects with open-angle glaucoma (OAG) or ocular hypertension (OHT). Pooled analysis of two phase 3, randomized, multicenter, double-masked, parallel-group, noninferiority trials (APOLLO and LUNAR), each with open-label safety extension phases. Adults with OAG or OHT were randomized 2:1 to double-masked treatment with LBN once daily (qd) or timolol twice daily (bid) for 3 months followed by open-label LBN treatment for 3 (LUNAR) or 9 (APOLLO) months. IOP was measured at 8 AM, 12 PM, and 4 PM at week 2, week 6, and months 3, 6, 9, and 12. Of the 840 subjects randomized, 774 (LBN, n=523; timolol crossover to LBN, n=251) completed the efficacy phase, and 738 completed the safety extension phase. Mean IOP was significantly lower with LBN versus timolol at all 9 evaluation timepoints during the efficacy phase (P<0.001). A significantly greater proportion of LBN-treated subjects attained a mean IOP ≤18 mm Hg and IOP reduction ≥25% from baseline versus timolol-treated subjects (P<0.001). The IOP reduction with LBN was sustained through the safety phase; subjects crossed over from timolol to LBN experienced additional significant IOP lowering (P≤0.009). Both treatments were well tolerated, and there were no safety concerns with long-term LBN treatment. In this pooled analysis of subjects with OAG and OHT, LBN 0.024% qd provided greater IOP-lowering compared with timolol 0.5% bid and maintained lowered IOP through 12 months. LBN demonstrated a safety profile comparable to that of prostaglandin analogs.

  2. The Early Miocene Critical Zone at Karungu, Western Kenya: An Equatorial, Open Habitat with Few Primate Remains

    NASA Astrophysics Data System (ADS)

    Lukens, William E.; Lehmann, Thomas; Peppe, Daniel J.; Fox, David L.; Driese, Steven G.; McNulty, Kieran P.

    2017-10-01

    Early Miocene outcrops near Karungu, Western Kenya, preserve a range of fluvio-lacustrine, lowland landscapes that contain abundant fossils of terrestrial and aquatic vertebrates. Primates are notably rare among these remains, although nearby early Miocene strata on Rusinga Island contain a rich assemblage of fossilized catarrhines and strepsirrhines. To explore possible environmental controls on the occurrence of early Miocene primates, we performed a deep-time Critical Zone (DTCZ) reconstruction focused on floodplain paleosols at the Ngira locality in Karungu. We specifically focused on a single stratigraphic unit (NG15), which preserves moderately developed paleosols that contain a microvertebrate fossil assemblage. Although similarities between deposits at Karungu and Rusinga Island are commonly assumed, physical sedimentary processes, vegetative cover, soil hydrology, and some aspects of climate state are notably different between the two areas. Estimates of paleoclimate parameters using paleosol B horizon elemental chemistry and morphologic properties are consistent with seasonal, dry subhumid conditions, occasional waterlogging, and herbaceous vegetation. The reconstructed small mammal community indicates periodic waterlogging and open-canopy conditions. Based on the presence of herbaceous root traces, abundant microcharcoal, and pedogenic carbonates with high stable carbon isotope ratios, we interpret NG15 to have formed under a warm, seasonally dry, open riparian woodland to wooded grassland, in which at least a subset of the vegetation was likely C4 biomass. Our results, coupled with previous paleoenvironmental interpretations for deposits on Rusinga Island, demonstrate that there was considerable environmental heterogeneity ranging from open to closed habitats in the early Miocene. We hypothesize that the relative paucity of primates at Karungu was driven by their environmental preference for locally abundant closed canopy vegetation, which was likely

  3. Angles in the Sky?

    NASA Astrophysics Data System (ADS)

    Behr, Bradford

    2005-09-01

    Tycho Brahe lived and worked in the late 1500s before the telescope was invented. He made highly accurate observations of the positions of planets, stars, and comets using large angle-measuring devices of his own design. You can use his techniques to observe the sky as well. For example, the degree, a common unit of measurement in astronomy, can be measured by holding your fist at arm's length up to the sky. Open your fist and observe the distance across the sky covered by the width of your pinky fingernail. That is, roughly, a degree! After some practice, and knowing that one degree equals four minutes, you can measure elapsed time by measuring the angle of the distance that the Moon appears to have moved and multiplying that number by four. You can also figure distances and sizes of things. These are not precise measurements, but rough estimates that can give you a "close-enough" answer.

  4. Proteomic Alterations in Aqueous Humor From Patients With Primary Open Angle Glaucoma.

    PubMed

    Sharma, Shruti; Bollinger, Kathryn E; Kodeboyina, Sai Karthik; Zhi, Wenbo; Patton, Jordan; Bai, Shan; Edwards, Blake; Ulrich, Lane; Bogorad, David; Sharma, Ashok

    2018-05-01

    Primary open angle glaucoma (POAG) is the most prevalent form of glaucoma, accounting for approximately 90% of all cases. The aqueous humor (AH), a biological fluid in the anterior and posterior chambers of the eye, is involved in a multitude of functions including the maintenance of IOP and ocular homeostasis. This fluid is very close to the pathologic site and is also known to have a significant role in glaucoma pathogenesis. The purpose of this study was to identify proteomic alterations in AH from patients with POAG. AH samples were extracted from 47 patients undergoing cataract surgery (controls: n = 32; POAG: n = 15). Proteomic analysis of the digested samples was accomplished by liquid-chromatography-mass spectrometry. The identified proteins were evaluated using a variety of statistical and bioinformatics methods. A total of 33 proteins were significantly altered in POAG subjects compared with the controls. The most abundant proteins in POAG subjects are IGKC (13.56-fold), ITIH4 (4.1-fold), APOC3 (3.36-fold), IDH3A (3.11-fold), LOC105369216 (2.98-fold). SERPINF2 (2.94-fold), NPC2 (2.88-fold), SUCLG2 (2.70-fold), KIAA0100 (2.29-fold), CNOT4 (2.23-fold), AQP4 (2.11-fold), COL18A1 (2.08-fold), NWD1 (2.07-fold), and TMEM120B (2.06-fold). A significant increasing trend in the odds ratios of having POAG was observed with increased levels of these proteins. Proteins identified in this study are implicated in signaling, glycosylation, immune response, molecular transport, and lipid metabolism. The identified candidate proteins may be potential biomarkers associated with POAG development and may lead to more insight in understanding the mechanisms underlying the pathogenesis of this disease.

  5. Starflo glaucoma implant: early experience in Hungary

    PubMed Central

    István, Cseke; Péter, Vámosi; Mária, Bausz

    2016-01-01

    Aim: To present the early experience with the implantation technique, safety and efficiency of STARflo™ device for open angle glaucoma (OAG). Methods: referring intra- and postoperative clinical experience with a series of seven cases in three glaucoma centers in Hungary. Results: No intraoperative complications were observed. Postoperative inflammatory signs disappeared rapidly. The mean IOP reduction was from 27,6 ± 5,0 mmHg to 18,9±3,4 mmHg (32% reduction/ patient) at six months postoperatively. Conclusion: STARflo™ implant was safe and (except for one case with neovascular glaucoma) effective in our cases. The learning curve for experienced anterior segment surgeons was short. PMID:27220226

  6. Effect of aperture geometry on heat transfer in tilted partially open cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elsayed, M.M.; Chakroun, W.

    1999-11-01

    Heat transfer in cavities is receiving increasing attention because of the various applications in engineering; e.g., passive solar heating, energy conservation in buildings, solar concentrating receivers, and electronic equipment. Here, convection from a square, tilted partially open cavity was investigated experimentally. The experiment was carried out to study the effect of the aperture geometry on the heat transfer between the cavity and the surrounding air. Four different geometrical arrangements for the opening were investigated: (1) high wall slit, (2) low wall slit, (3) centered wall slit, and (4) uniform wall slots. Each opening arrangement was studied at opening ratios (i.e.,more » ratio of opening height to cavity height) of 0.25, 0.5, and 0.75. The average heat transfer coefficient between the cavity and the surrounding air was estimated for each geometrical arrangement for tilt angles ranging from {minus}90 deg to +90 deg with increments of 15 deg and at a constant heat flux Grashof number of 5.5 x 10{sup 8}. The results showed that for tilt angles between 90 and 75 deg, the heat transfer coefficient has a small value that is independent of the geometrical arrangement of the opening. The value of the heat transfer coefficient increases sharply with decreasing tilt angle until an angle value of zero degrees is reached. The increase in the heat transfer coefficient continues in the negative range of tilt angle but not in the same rate as in the positive range of the tilt angle. The uniform slot arrangement gave in general higher heat transfer coefficient than the other three arrangements of the opening. Large differences in the heat transfer coefficient were observed between the high and the low wall slits where the high wall slit is found to transfer more heat to the surroundings than the low wall slit. Correlations were developed to predict the average Nusselt number of the cavity in terms of the opening ratio and the cavity tilt angle for cavities

  7. Medical management of primary open-angle glaucoma: Best practices associated with enhanced patient compliance and persistency.

    PubMed

    Kulkarni, Sadhana V; Damji, Karim F; Buys, Yvonne M

    2008-02-02

    Primary open angle glaucoma is a chronic optic neuropathy often requiring lifelong treatment. Patient compliance, adherence and persistence with therapy play a vital role in improved outcomes by reducing morbidity and the economic consequences that are associated with disease progression. A literature review including searches of The Cochrane Library, MEDLINE, PubMed, conference proceedings, and bibliographies of identified articles reveals the enormous public health burden in various populations due to the impact of glaucoma associated visual impairment on the overall quality of life eg, fear of blindness, inability to work in certain occupations, driving restrictions, motor vehicle accidents, falls, and general health status. Providing specific definitions for the frequently misunderstood terms "compliance, persistence and adherence" with reference to medication use is central not only for monitoring patients' drug dosing histories and clinical outcomes but also for subsequent research. In this review article, a summary of the advantages/disadvantages including cost-effectiveness of various medical approaches to glaucoma treatment, techniques employed for measuring patient compliance and actual patient preferences for therapy are outlined. We conclude by identifying the key barriers to ongoing treatment and suggest some best practices to enhance compliance and persistence.

  8. Medical management of primary open-angle glaucoma: Best practices associated with enhanced patient compliance and persistency

    PubMed Central

    Kulkarni, Sadhana V; Damji, Karim F; Buys, Yvonne M

    2008-01-01

    Primary open angle glaucoma is a chronic optic neuropathy often requiring lifelong treatment. Patient compliance, adherence and persistence with therapy play a vital role in improved outcomes by reducing morbidity and the economic consequences that are associated with disease progression. A literature review including searches of The Cochrane Library, MEDLINE, PubMed, conference proceedings, and bibliographies of identified articles reveals the enormous public health burden in various populations due to the impact of glaucoma associated visual impairment on the overall quality of life eg, fear of blindness, inability to work in certain occupations, driving restrictions, motor vehicle accidents, falls, and general health status. Providing specific definitions for the frequently misunderstood terms “compliance, persistence and adherence” with reference to medication use is central not only for monitoring patients’ drug dosing histories and clinical outcomes but also for subsequent research. In this review article, a summary of the advantages/disadvantages including cost-effectiveness of various medical approaches to glaucoma treatment, techniques employed for measuring patient compliance and actual patient preferences for therapy are outlined. We conclude by identifying the key barriers to ongoing treatment and suggest some best practices to enhance compliance and persistence. PMID:19920977

  9. Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle.

    PubMed

    Sakata, Lisandro M; Lavanya, Raghavan; Friedman, David S; Aung, Han T; Gao, Hong; Kumar, Rajesh S; Foster, Paul J; Aung, Tin

    2008-05-01

    To compare the performance of gonioscopy and anterior segment (AS) optical coherence tomography (OCT) in detecting angle closure in the different quadrants of the anterior chamber angle (ACA). Cross-sectional observational study. Five hundred two consecutive subjects more than 50 years of age with no previous ophthalmic problems recruited from a community clinic in Singapore. All subjects underwent gonioscopy and AS OCT imaging in the dark. Using gonioscopy, the ACA was graded using the Scheie system by a single examiner masked to AS OCT findings. The ACA in a particular quadrant was classified as closed if the posterior trabecular meshwork could not be seen on gonioscopy. A closed ACA on AS OCT imaging was defined by the presence of any contact between the iris and angle wall anterior to the scleral spur. After excluding eyes with poor image quality, a total of 423 right eyes were included in the analysis. A closed angle in at least 1 quadrant was observed in 59% of the eyes by AS OCT and in 33% of the eyes by gonioscopy (P<0.001), with fair agreement between the two methods (kappa = 0.40). The frequency of closed angles by AS OCT and gonioscopy were 48% versus 29% superiorly, 43% versus 22% inferiorly, 18% versus 14% nasally, and 12% versus 20% temporally, respectively. Of the 119 of 1692 quadrants that were closed on gonioscopy but open on AS OCT, a steep iris profile was present in 61 (51%) of 119 quadrants on AS OCT, and of the 276 of 1692 quadrants that were open on gonioscopy but closed on AS OCT, 196 (71%) of 276 quadrants showed short iridoangle contact on AS OCT. The highest rates of closed angles on gonioscopy and AS OCT images were observed in the superior quadrant. Anterior segment OCT tended to detect more closed ACAs than gonioscopy, particularly in the superior and inferior quadrants. Variations in the iris profile and level of iridoangle contact also may explain some of the differences seen between gonioscopy and AS OCT.

  10. Microstructure of the optic disc pit in open-angle glaucoma.

    PubMed

    Choi, Yun Jeong; Lee, Eun Ji; Kim, Bo Hyuk; Kim, Tae-Woo

    2014-11-01

    To investigate the structural and clinical characteristics of the optic disc pit (ODP) in primary open-angle glaucoma (POAG) via enhanced depth imaging (EDI) spectral-domain optical coherence tomography (SD-OCT). Prospective, observational case series. Seventy POAG eyes clinically diagnosed with an ODP via stereo disc photography. Optic discs were scanned using EDI SD-OCT. Serial horizontal and vertical B-scan images covering the optic discs were obtained from each eye. The structural characteristics of the ODP were investigated via 3-dimensional images constructed from the serial B-scans, focusing on the presence of alterations in the contour of the lamina cribrosa (LC) or prelaminar tissue (PLT), in conjunction with associated clinical characteristics. The structural characteristics of the ODP and associated clinical characteristics. In the EDI SD-OCT images, the ODP was viewed as an isolated alteration of the LC (n = 14, 20.0%) or PLT (n = 16, 22.9%) or an alteration of both the LC and PLT (n = 40, 57.1%). Alterations of the LC were located at the mid-periphery near the LC insertion (n = 17) or far periphery adjacent to the LC insertion (n = 37), and the depth of alteration was deep (n = 23), involving nearly full-thickness LC, or shallow (n = 31), with partially visible LC at the base. Fifty-four eyes (77.1%) exhibited parafoveal visual field (VF) defect within 10 degrees of fixation, and in 98.1% of these eyes (53/54) it was spatially associated with the location of ODP. The parafoveal VF defect was more prevalent in eyes with LC alteration than those without (83.3% vs. 56.2%, P = 0.023) and in eyes with deep LC defect than those with shallow defect (95.7% vs. 74.2%, P = 0.036). Disc hemorrhage (32.4% vs. 0.0%, P = 0.008) and peripapillary retinoschisis (18.9 vs. 0.0%, P = 0.055) were more strongly associated with LC alterations located at the far periphery than at the mid-periphery. Enhanced depth imaging SD-OCT facilitated visualization of the varied

  11. Early Opening of Seychelles and India: the Gop Basin Revisited

    NASA Astrophysics Data System (ADS)

    Dyment, J.; Vadakkeyakath, Y.; Bhattacharya, G.

    2012-12-01

    The deep offshore region located between the India-Pakistan continental margin and the Laxmi Ridge continental sliver contains valuable imprints of the early oceanic opening phase between India and the Seychelles. The acquisition of wide-angle deep seismic data by British scientists in 2003 provided new information about the deep structure and nature of the crust [1,2]. These data complement the large amount of seismic reflection profiles, altimetry-derived gravity and marine magnetic data which allow mapping the structure and determining the age of the oceanic crust [3,4,5]. Although these authors all agree on the oceanic nature of the Gop Basin, they surprisingly differ on the extent of the oceanic crust, the location of the extinct spreading center and the age of the basin. Here we re-evaluate published interpretations of the Gop Basin in light of all available data. The major discrepancy between [1,2,4] and [5] is the location of the extinct spreading center. [1,2,4] place it on an unnamed basement high located at 19°55'N, whereas [5] identify it with the Palitana Ridge at 19°25'N. Checking the location of the basement high of [1,2,4] on the basement isobath map of [3], based on many seismic reflection profiles, reveals that this basement high actually is an isolated feature of limited extent, which at best can be considered as part of a NE-SW trending basement high zone. This basement high locally coincides with a strong positive magnetic anomaly and a narrow gravity anomaly low but the trend of these anomalies is E-W, in contrast to the NE-SW trend of the basement in this area. For these reasons, this basement high probably is not the location of the Gop Basin extinct spreading center. Conversely, on the basement isobath map of [3], the Palitana Ridge appears as a prominent E-W high, located in the middle of a broad E-W graben, the Gop Basin. It extends over 200 km and is flanked on both sides by basement 2000 m deeper. On free air gravity anomaly maps, the

  12. Patient-reported vision-related quality of life differences between superior and inferior hemifield visual field defects in primary open-angle glaucoma.

    PubMed

    Cheng, Hui-Chen; Guo, Chao-Yu; Chen, Mei-Ju; Ko, Yu-Chieh; Huang, Nicole; Liu, Catherine Jui-ling

    2015-03-01

    Previous studies have found that glaucoma is associated with impaired patient-reported vision-related quality of life (pVRQOL) but few, to our knowledge, have assessed how the visual field (VF) defect location impacts the pVRQOL. To investigate the associations of VF defects in the superior vs inferior hemifields with pVRQOL outcomes in patients with primary open-angle glaucoma. Prospective cross-sectional study at a tertiary referral center from March 1, 2012, to January 1, 2013, including patients with primary open-angle glaucoma who had a best-corrected visual acuity in the better eye equal to or better than 20/60 and reliable VF tests. The pVRQOL was assessed by a validated Taiwanese version of the 25-item National Eye Institute Visual Function Questionnaire. Reliable VF tests obtained within 3 months of enrollment were transformed to binocular integrated VF (IVF). The IVF was further stratified by VF location (superior vs inferior hemifield). The association between each domain of the 25-item National Eye Institute Visual Function Questionnaire and superior or inferior hemifield IVF was determined using multivariable linear regression analysis. The analysis included 186 patients with primary open-angle glaucoma with a mean age of 59.1 years (range, 19-86 years) and IVF mean deviation (MD) of -4.84 dB (range, -27.56 to 2.17 dB). In the multivariable linear regression analysis, the MD of the full-field IVF showed positive associations with near activities (β = 0.05; R2 = 0.20; P < .001), vision-specific role difficulties (β = 0.04; R2 = 0.19; P = .01), vision-specific dependency (β = 0.04; R2 = 0.20; P < .001), driving (β = 0.05; R2 = 0.24; P < .001), peripheral vision (β = 0.03; R2 = 0.18; P = .02), and composite scores (β = 0.04; R2 = 0.27; P = .005). Subsequent analysis showed that the MD of the superior hemifield IVF was associated only with near activities (β = 0.04; R2

  13. Early and mid-term outcomes of endovascular and open surgical repair of non-dissected aortic arch aneurysm†.

    PubMed

    Hori, Daijiro; Okamura, Homare; Yamamoto, Takahiro; Nishi, Satoshi; Yuri, Koichi; Kimura, Naoyuki; Yamaguchi, Atsushi; Adachi, Hideo

    2017-06-01

    With the introduction of endovascular stent graft technology, a variety of surgical options are available for patients with aortic aneurysms. We sought to evaluate early-term and mid-term outcomes of patients undergoing endovascular and open surgical repair for non-dissected aortic arch aneurysm. Overall, 200 patients underwent treatment for isolated non-dissected aortic arch aneurysm between January 2008 and February 2016: 133 patients had open surgery and 67, endovascular repair. Early-term and mid-term outcomes were compared. Seventy percent ( n  = 47) needing endovascular repair underwent fenestrated stent graft and 30% ( n  = 20) underwent the debranched technique. Patients in the open surgery group were younger (71 vs 75 years, P  < 0.001) and had a lower prevalence of ischaemic heart disease (11% vs 35%, P  < 0.001). Intensive care unit stay (1 vs 3 days, P  < 0.001), hospital stay (11 vs 17 days, P  < 0.001) and surgical time (208 vs 390 min, P  < 0.001) were lower in the endovascular repair group than in the open surgery group. There were 3 in-hospital deaths each in the open surgery and endovascular groups (2% vs 5%, respectively, P  = 0.40). Mid-term survival ( P  < 0.001) and freedom from reintervention ( P  = 0.009) were better in the open surgery than in the endovascular repair group. No aneurysm-related deaths were observed. The propensity-matched comparison ( n  = 58) demonstrated that survival was better in the open surgery group ( P  = 0.011); no significant difference was seen in the reintervention rate ( P  = 0.28). Close follow-up for re-intervention may reduce the risk for aneurysm-related deaths and provide acceptable outcomes in patients undergoing endovascular repair. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Open for Business

    ERIC Educational Resources Information Center

    Voyles, Bennett

    2007-01-01

    People know about the Sakai Project (open source course management system); they may even know about Kuali (open source financials). So, what is the next wave in open source software? This article discusses business intelligence (BI) systems. Though open source BI may still be only a rumor in most campus IT departments, some brave early adopters…

  15. Comparison of a travoprost BAK-free formulation preserved with polyquaternium-1 with BAK-preserved travoprost in ocular hypertension or open-angle glaucoma.

    PubMed

    Gandolfi, Stefano; Paredes, Tania; Goldberg, Ivan; Coote, Michael; Wells, Anthony; Volksone, Lasma; Pillai, Manju R; Stalmans, Ingeborg; Denis, Philippe

    2012-01-01

    To demonstrate that the intraocular pressure (IOP)-lowering effect of travoprost 0.004% preserved with polyquaternium-1 (travoprost benzalkonium chloride [BAK]-free) is non-inferior to that of travoprost 0.004% preserved with benzalkonium chloride (travoprost BAK) in patients with ocular hypertension or open-angle glaucoma. A total of 371 patients randomly received travoprost BAK-free (n=185) or travoprost BAK (n=186) dosed once daily in the evening for 3 months. Patients were evaluated at 9 am, 11 AM, and 4 PM at baseline, weeks 2 and 6, and month 3. Intraocular pressure was also evaluated 36 and 60 hours after the month 3 visit. Travoprost BAK-free is non-inferior to travoprost BAK. The 95% upper confidence limits for the difference in mean IOP at month 3 (primary efficacy) were 0.5 mmHg, 0.6 mmHg, and 0.5 mmHg, at 9 AM, 11 AM, and 4 PM, respectively. Mean IOP reductions from baseline ranged from 7.6 to 8.7 mmHg in the travoprost BAK-free group and from 7.7 to 9.2 mmHg in the travoprost BAK group. At 36 and 60 hours after the last dose, mean IOP remained 6.8 mmHg and 5.7 mmHg below baseline in the travoprost BAK-free group, vs 7.3 mmHg and 6.0 mmHg in the travoprost BAK group, respectively. The safety profile of travoprost BAK-free was similar to that of travoprost BAK. Travoprost BAK-free safely and effectively lowers IOP in eyes with open-angle glaucoma or ocular hypertension. This BAK-free formulation has comparable safety, efficacy, and duration of IOP-lowering effect to travoprost preserved with BAK. Travoprost BAK-free is an effective option for IOP reduction while avoiding BAK exposure.

  16. Graft Angle its Relationship to Tomato Plant Survival

    USDA-ARS?s Scientific Manuscript database

    Growing plants that can withstand the rigors of open field production is imperative. This study examines the relationship of tensile strength to graft angle and plant survival. Tomato seedlings of ‘FL47’ and ‘Rutgers’ were used as scions on ‘Roma’ rootstock under greenhouse and healing chamber con...

  17. Does human immunodeficiency virus status affect early wound healing in open surgically stabilised tibial fractures?: A prospective study.

    PubMed

    Howard, N E; Phaff, M; Aird, J; Wicks, L; Rollinson, P

    2013-12-01

    We compared early post-operative rates of wound infection in HIV-positive and -negative patients presenting with open tibial fractures managed with surgical fixation. The wounds of 84 patients (85 fractures), 28 of whom were HIV positive and 56 were HIV negative, were assessed for signs of infection using the ASEPIS wound score. There were 19 women and 65 men with a mean age of 34.8 years. A total of 57 fractures (17 HIV-positive, 40 HIV-negative) treated with external fixation were also assessed using the Checkett score for pin-site infection. The remaining 28 fractures were treated with internal fixation. No significant difference in early post-operative wound infection between the two groups of patients was found (10.7% (n = 3) vs 19.6% (n = 11); relative risk (RR) 0.55 (95% confidence interval (CI) 0.17 to 1.8); p = 0.32). There was also no significant difference in pin-site infection rates (17.6% (n = 3) vs 12.5% (n = 5); RR 1.62 (95% CI 0.44 to 6.07); p = 0.47). The study does not support the hypothesis that HIV significantly increases the rate of early wound or pin-site infection in open tibial fractures. We would therefore suggest that a patient's HIV status should not alter the management of open tibial fractures in patients who have a CD4 count > 350 cells/μl.

  18. Acoustic metamaterials with broadband and wide-angle impedance matching

    NASA Astrophysics Data System (ADS)

    Liu, Chenkai; Luo, Jie; Lai, Yun

    2018-04-01

    We propose a general approach to design broadband and wide-angle impedance-matched acoustic metamaterials. Such an unusual acoustic impedance matching characteristic can be well explained by using a spatially dispersive effective medium theory. For demonstrations, we used silicone rubber, which has a huge impedance contrast with water, to design one- and two-dimensional acoustic structures which are almost perfectly impedance matched to water for a wide range of incident angles and in a broad frequency band. Our work opens up an approach to realize extraordinary acoustic impedance matching properties via metamaterial-design techniques.

  19. Randomized trial of brinzolamide/brimonidine versus brinzolamide plus brimonidine for open-angle glaucoma or ocular hypertension.

    PubMed

    Gandolfi, Stefano A; Lim, John; Sanseau, Ana Cristina; Parra Restrepo, Juan Camilo; Hamacher, Thomas

    2014-12-01

    Fixed-combination intraocular pressure (IOP)-lowering medications simplify treatment regimens for patients requiring 2 ocular hypotensive agents to maintain sufficiently low IOP. The aim of this study was to evaluate the safety and efficacy of fixed-combination brinzolamide 1%/brimonidine 0.2% (BBFC) versus concomitant administration of brinzolamide 1% plus brimonidine 0.2% (BRINZ + BRIM) in patients with open-angle glaucoma or ocular hypertension. This was a prospective, phase 3, multicenter, double-masked, 6-month trial. Patients who had insufficient IOP control with monotherapy or who were receiving 2 IOP-lowering medications were randomized 1:1 to receive twice-daily BBFC or BRINZ + BRIM. IOP was assessed at 9 a.m. and 11 a.m. during week 2, week 6, month 3, and month 6 visits. The primary efficacy endpoint was mean diurnal IOP change from baseline to month 3; noninferiority was concluded if the upper limit of the 95% CI of the between-group difference was <1.5 mmHg. Supportive endpoints included mean IOP, IOP change from baseline, and percentage of patients with IOP <18 mmHg. Adverse events were recorded. The mean diurnal IOP change from baseline with BBFC (least squares mean ± standard error -8.5 ± 0.16 mmHg) was noninferior to that with BRINZ + BRIM (-8.3 ± 0.16 mmHg; mean difference -0.1 mmHg; 95% CI -0.5 to 0.2 mmHg). The upper limits of the 95% CIs were <1.5 mmHg at all time points. Decreases from baseline >8 mmHg were observed for least squares mean diurnal IOP in both groups as early as week 2 and continued to the end of the study. The results of all other supportive endpoints were similar to the primary efficacy endpoint. The most common ocular adverse drug reactions were hyperemia of the eye (reported as ocular or conjunctival hyperemia), visual disturbances, ocular allergic reactions, and ocular discomfort. Common systemic adverse drug reactions included dysgeusia, oral dryness, and fatigue/drowsiness. Brinzolamide 1

  20. Static balance according to hip joint angle of unsupported leg during one-leg standing.

    PubMed

    Cha, Ju-Hyung; Kim, Jang-Joon; Ye, Jae-Gwan; Lee, Seul-Ji; Hong, Jeong-Mi; Choi, Hyun-Kyu; Choi, Ho-Suk; Shin, Won-Seob

    2017-05-01

    [Purpose] This study aimed to determine static balance according to hip joint angle of the unsupported leg during one-leg standing. [Subjects and Methods] Subjects included 45 healthy adult males and females in their 20s. During one-leg standing on the non-dominant leg, the position of the unsupported leg was classified according to hip joint angles of point angle was class. Static balance was then measured using a force plate with eyes open and closed. The total length, sway velocity, maximum deviation, and velocity on the mediolateral and anteroposterior axes of center of pressure were measured. [Results] In balance assessment with eyes open, there were significant differences between groups according to hip joint angle, except for maximum deviation on the anteroposterior axis. In balance assessment with eyes closed, there were significant differences between total length measurements at 0° and 30°, 60° and between 30° and 90°. There were significant differences between sway velocity measurements at 0° and 30° and between 30° and 90°. [Conclusion] Thus, there were differences in static balance according to hip joint angle. It is necessary to clearly identify the hip joint angle during one-leg standing testing.

  1. Association of Baseline Anterior Segment Parameters With the Development of Incident Gonioscopic Angle Closure.

    PubMed

    Nongpiur, Monisha E; Aboobakar, Inas F; Baskaran, Mani; Narayanaswamy, Arun; Sakata, Lisandro M; Wu, Renyi; Atalay, Eray; Friedman, David S; Aung, Tin

    2017-03-01

    Baseline anterior segment imaging parameters associated with incident gonioscopic angle closure, to our knowledge, are unknown. To identify baseline quantitative anterior segment optical coherence tomography parameters associated with the development of incident gonioscopic angle closure after 4 years among participants with gonioscopically open angles at baseline. Three hundred forty-two participants aged 50 years or older were recruited to participate in this prospective, community-based observational study. Participants underwent gonioscopy and anterior segment optical coherence tomography imaging at baseline and after 4 years. Custom image analysis software was used to quantify anterior chamber parameters from anterior segment optical coherence tomography images. Baseline anterior segment optical coherence tomography measurements among participants with gonioscopically open vs closed angles at follow-up. Of the 342 participants, 187 (55%) were women and 297 (87%) were Chinese. The response rate was 62.4%. Forty-nine participants (14.3%) developed gonioscopic angle closure after 4 years. The mean age (SD) at baseline of the 49 participants was 62.9 (8.0) years, 15 (30.6%) were men, and 43 (87.8%) were Chinese. These participants had a smaller baseline angle opening distance at 750 µm (AOD750) (0.15 mm; 95% CI, 0.12-0.18), trabecular iris surface area at 750 µm (0.07 mm2; 95% CI, 0.05-0.08), anterior chamber area (30 mm2; 95% CI, 2.27-3.74), and anterior chamber volume (24.32 mm2; 95% CI, 18.20-30.44) (all P < .001). Baseline iris curvature (-0.08; 95% CI, -0.12 to -0.04) and lens vault (LV) measurements (-0.29 mm; 95% CI, -0.37 to -0.21) were larger among these participants ( all P < .001). A model consisting of the LV and AOD750 measurements explained 38% of the variance in gonioscopic angle closure occurring at 4 years, with LV accounting for 28% of this variance. For every 0.1 mm increase in LV and 0.1 mm decrease in AOD750, the odds of developing

  2. Effects of diurnal, lighting, and angle-of-incidence variation on anterior segment optical coherence tomography (AS-OCT) angle metrics.

    PubMed

    Akil, Handan; Dastiridou, Anna; Marion, Kenneth; Francis, Brian A; Chopra, Vikas

    2017-03-23

    First reported study to assess the effect of diurnal variation on anterior chamber angle measurements, as well as, to re-test the effects of lighting and angle-of-incidence variation on anterior chamber angle (ACA) measurements acquired by time-domain anterior segment optical coherence tomography (AS-OCT). A total of 30 eyes from 15 healthy, normal subjects underwent anterior chamber imaging using a Visante time-domain AS-OCT according to an IRB-approved protocol. For each eye, the inferior angle was imaged twice in the morning (8 am - 10 am) and then again in the afternoon (3 pm - 5 pm), under light meter-controlled conditions with ambient room lighting 'ON' and lights 'OFF', and at 5° angle of incidence increments. The ACA metrics measured for each eye were: angle opening distance (AOD, measured 500 and 750 μm anterior from scleral spur), the trabecular-iris-space area (TISA, measured 500 and 750 μm anterior from scleral spur), and scleral spur angle. Measurements were performed by masked, certified Reading Center graders using the Visante's Internal Measurement Tool. Differences in measurements between morning and afternoon, lighting variations, and angle of incidence were compared. Mean age of the participants was 31.2 years (range 23-58). Anterior chamber angle metrics did not differ significantly from morning to afternoon imaging, or when the angle of incidence was offset by 5° in either direction away from the inferior angle 6 o'clock position. (p-value 0.13-0.93). Angle metrics at the inferior corneal limbus, 6 o'clock position (IC270), with room lighting 'OFF', showed a significant decrease (p < 0.05) compared to room lighting 'ON'. There does not appear to be significant diurnal variation in AS-OCT parameters in normal individuals, but lighting conditions need to be strictly controlled since variation in lighting led to significant variability in AS-OCT parameters. No changes in ACA parameters were noted by varying the angle

  3. Velocity and size of droplets in dense region of diesel fuel spray on transient needle opening condition

    NASA Astrophysics Data System (ADS)

    Ueki, Hironobu; Ishida, Masahiro; Sakaguchi, Daisaku

    2005-06-01

    In order to investigate the effect of transient needle opening on early stage of spray behavior, simultaneous measurements of velocity and size of droplet were conducted by a newly developed laser 2-focus velocimeter (L2F). The micro-scale probe of the L2F was consisted of two foci with a distance of 36 µm. The tested nozzle had a single hole with a diameter of 0.2 mm. The measurements of injection pressure, needle lift, and crank angle were synchronized with the spray measurement by the L2F at the position 10 mm downstream from the nozzle exit. It has been clearly shown that the velocity and size of droplet increase with needle valve opening and that the probability density distribution of droplet size can be fitted to the Nukiyama-Tanasawa distribution under the transient needle opening condition.

  4. Argon laser peripheral iridoplasty for angle-closure glaucoma in sibilings with weill-marchesani syndrome.

    PubMed

    Ritch, R; Solomon, L D

    1992-01-01

    A patient with Weill-Marchesani syndrome and angle-closure glaucoma had persistent appositional closure after laser iridotomy that was unrelieved by topical application of either miotic or cycloplegic agents. Argon laser peripheral iridoplasty successfully opened the angle. The patient's sister also had Weill-Marchesani syndrome and angle closure unrelieved by laser iridotomy. Angle closure in Weill-Marchesani syndrome and the response to laser iridotomy and treatment with either miotic or cycloplegic agents may be complex and depends on the relative proportion of pupillary block as a mechanism underlying the angle closure, the functional status of the zonular apparatus, and the degree of angle crowding by the peripheral iris in the presence or absence of peripheral anterior synechiae.

  5. Micro-Bypass Implantation for Primary Open-Angle Glaucoma Combined with Phacoemulsification: 4-Year Follow-Up

    PubMed Central

    Fea, Antonio Maria; Consolandi, Giulia; Zola, Marta; Pignata, Giulia; Cannizzo, Paola; Lavia, Carlo; Rolle, Teresa; Grignolo, Federico Maria

    2015-01-01

    Purpose. To report the long-term follow-up results in patients with cataract and primary open-angle glaucoma (POAG) randomly assigned to cataract surgery combined with micro-bypass stent implantation or phacoemulsification alone. Methods. 36 subjects with cataract and POAG were randomized in a 1 : 2 ratio to either iStent implantation and cataract surgery (combined group) or cataract surgery alone (control group). 24 subjects agreed to be evaluated again 48 months after surgery. Patients returned one month later for unmedicated washout assessment. Results. At the long-term follow-up visit we reported a mean IOP of 15,9 ± 2,3 mmHg in the iStent group and 17 ± 2,5 mmHg in the control group (p = NS). After washout, a 14,2% between group difference in favour of the combined group was statistically significant (p = 0,02) for mean IOP reduction. A significant reduction in the mean number of medications was observed in both groups compared to baseline values (p = 0,005 in the combined group and p = 0,01 in the control group). Conclusion. Patients in the combined group maintained low IOP levels after long-term follow-up. Cataract surgery alone showed a loss of efficacy in controlling IOP over time. Both treatments reduced the number of ocular hypotensive medications prescribed. This trial is registered with: NCT00847158. PMID:26587282

  6. Evidence-based practice guideline of Chinese herbal medicine for primary open-angle glaucoma (qingfeng -neizhang)

    PubMed Central

    Yang, Yingxin; Ma, Qiu-yan; Yang, Yue; He, Yu-peng; Ma, Chao-ting; Li, Qiang; Jin, Ming; Chen, Wei

    2018-01-01

    Abstract Background: Primary open angle glaucoma (POAG) is a chronic, progressive optic neuropathy. The aim was to develop an evidence-based clinical practice guideline of Chinese herbal medicine (CHM) for POAG with focus on Chinese medicine pattern differentiation and treatment as well as approved herbal proprietary medicine. Methods: The guideline development group involved in various pieces of expertise in contents and methods. Authors searched electronic databases include CNKI, VIP, Sino-Med, Wanfang data, PubMed, the Cochrane Library, EMBASE, as well as checked China State Food and Drug Administration (SFDA) from the inception of these databases to June 30, 2015. Systematic reviews and randomized controlled trials of Chinese herbal medicine treating adults with POAG were evaluated. Risk of bias tool in the Cochrane Handbook and evidence strength developed by the GRADE group were applied for the evaluation, and recommendations were based on the findings incorporating evidence strength. After several rounds of Expert consensus, the final guideline was endorsed by relevant professional committees. Results: CHM treatment principle and formulae based on pattern differentiation together with approved patent herbal medicines are the main treatments for POAG, and the diagnosis and treatment focusing on blood related patterns is the major domain. Conclusion: CHM therapy alone or combined with other conventional treatment reported in clinical studies together with Expert consensus were recommended for clinical practice. PMID:29595636

  7. Structure-Function Correlation Using Confocal Laser Ophthalmoscope in Primary Open-Angle Glaucoma and Pseudoexfoliative Glaucoma.

    PubMed

    Pappas, Theofanis; Founti, Panayiota; Yin, Xiang Jun; Koskosas, Archimidis; Anastasopoulos, Eleftherios; Salonikiou, Angeliki; Kilintzis, Vasilios; Antoniadis, Antonios; Ziakas, Nikolaos; Topouzis, Fotis

    2016-04-01

    To compare Heidelberg Retina Tomograph (HRT) optic disc parameters and structure-function correlation between primary open-angle glaucoma (POAG) and pseudoexfoliative glaucoma (PEXG). Prospective, observation case series. A total of 54 POAG and 33 PEXG cases, consecutively recruited from a University Glaucoma Service, underwent a comprehensive ophthalmic examination, including HRT optic disc imaging. Glaucoma definition required the presence of both structural and functional damage. One eye per subject was included in the analysis. T test, Mann-Whitney U test, and analysis of covariance were used to compare HRT parameters between POAG and PEXG, adjusting for age, mean deviation (MD) in the visual field, intraocular pressure, and disc area. The correlation between HRT and MD was assessed in each group. Cup area (P=0.048), height variation contour (P=0.016), and cup/disc area ratio (P=0.023) were higher in POAG, whereas the mean retinal nerve fiber layer thickness (P=0.048), retinal nerve fiber layer cross-section area (P=0.044), and rim area (P=0.048) were lower in POAG, compared with PEXG. The correlation of HRT parameters with MD was significant only in the POAG group. At a similar level of functional damage, POAG subjects presented with more pronounced structural damage than PEXG subjects. The correlation between HRT and visual field parameters was more evident in POAG, compared with PEXG.

  8. Evidence-based practice guideline of Chinese herbal medicine for primary open-angle glaucoma (qingfeng -neizhang).

    PubMed

    Yang, Yingxin; Ma, Qiu-Yan; Yang, Yue; He, Yu-Peng; Ma, Chao-Ting; Li, Qiang; Jin, Ming; Chen, Wei

    2018-03-01

    Primary open angle glaucoma (POAG) is a chronic, progressive optic neuropathy. The aim was to develop an evidence-based clinical practice guideline of Chinese herbal medicine (CHM) for POAG with focus on Chinese medicine pattern differentiation and treatment as well as approved herbal proprietary medicine. The guideline development group involved in various pieces of expertise in contents and methods. Authors searched electronic databases include CNKI, VIP, Sino-Med, Wanfang data, PubMed, the Cochrane Library, EMBASE, as well as checked China State Food and Drug Administration (SFDA) from the inception of these databases to June 30, 2015. Systematic reviews and randomized controlled trials of Chinese herbal medicine treating adults with POAG were evaluated. Risk of bias tool in the Cochrane Handbook and evidence strength developed by the GRADE group were applied for the evaluation, and recommendations were based on the findings incorporating evidence strength. After several rounds of Expert consensus, the final guideline was endorsed by relevant professional committees. CHM treatment principle and formulae based on pattern differentiation together with approved patent herbal medicines are the main treatments for POAG, and the diagnosis and treatment focusing on blood related patterns is the major domain. CHM therapy alone or combined with other conventional treatment reported in clinical studies together with Expert consensus were recommended for clinical practice.

  9. Factors associated with developing a fear of falling in subjects with primary open-angle glaucoma.

    PubMed

    Adachi, Sayaka; Yuki, Kenya; Awano-Tanabe, Sachiko; Ono, Takeshi; Shiba, Daisuke; Murata, Hiroshi; Asaoka, Ryo; Tsubota, Kazuo

    2018-02-13

    To investigate the relationship between clinical risk factors, including visual field (VF) defects and visual acuity, and a fear of falling, among patients with primary open-angle glaucoma (POAG). All participants answered the following question at a baseline ophthalmic examination: Are you afraid of falling? The same question was then answered every 12 months for 3 years. A binocular integrated visual field was calculated by merging a patient's monocular Humphrey field analyzer VFs, using the 'best sensitivity' method. The means of total deviation values in the whole, superior peripheral, superior central, inferior central, and inferior peripheral VFs were calculated. The relationship between these mean VF measurements, and various clinical factors, against patients' baseline fear of falling and future fear of falling was analyzed using multiple logistic regression. Among 392 POAG subjects, 342 patients (87.2%) responded to the fear of falling question at least twice in the 3 years study period. The optimal regression model for patients' baseline fear of falling included age, gender, mean of total deviation values in the inferior peripheral VF and number of previous falls. The optimal regression equation for future fear of falling included age, gender, mean of total deviation values in the inferior peripheral VF and number of previous falls. Defects in the inferior peripheral VF area are significantly related to the development of a fear of falling.

  10. Anthropometric Measures and their Relation to Incident Primary Open-Angle Glaucoma

    PubMed Central

    Pasquale, Louis R.; Willett, Walter C.; Rosner, Bernard A.; Kang, Jae Hee

    2009-01-01

    Purpose To assess the relation between anthropometric measures and incident primary open-angle glaucoma (POAG). Design Prospective cohort study. Participants We included 78,777 women in the Nurses Health Study and 41,352 men in the Health Professionals Follow-up Study. Methods Females and male health professionals were prospectively followed during the periods 1980–2004 and 1986–2004, respectively. Eligible participants were 40+ years old, did not have POAG at baseline and reported receiving eye examinations during follow-up. Information regarding anthropometric measures, potential confounders and ophthalmic status was updated using biennial questionnaires. During follow-up, 980 self-reported POAG cases were confirmed with medical record review. Main outcome measures Multivariable rate ratios (MVRR) of POAG and their 95% confidence intervals [95% CI]. Results There was no significant relation between cumulatively averaged body mass index (BMI) in kg/m2 and POAG overall (p for trend = 0.06). However, in relation to POAG with intraocular pressure (IOP) < 22 mm Hg at diagnosis, each unit increase in BMI was associated with a 6% reduced risk in women (MVRR = 0.94 [0.91–0.98]; p=0.01) but not for men (MVRR = 1.02 [0.96–1.09]; p=0.57); this gender difference was significant (p-heterogeneity =0.03). In multivariable analyses to explore the independent effects of height and weight, weight (as height-adjusted weight residuals; p for trend = 0.002), but not height (p for trend = 0.10) appeared to account for most of the inverse association between BMI and POAG with IOP ≤ 21 mm Hg at diagnosis in women. There was no association between BMI and POAG with IOP > 21 mm Hg at diagnosis for either gender (p for trend ≥ 0.26). Among women, analyses found that the relations between anthropometric parameters and the two POAG subtypes (POAG with IOP ≤ 21 mm Hg versus POAG with IOP > 21 mm Hg when diagnosed) were significantly different (p ≤ 0.0001). Conclusions Among

  11. Can early postoperative intraocular pressure predict success following mitomycin-C augmented trabeculectomy in primary angle-closure glaucoma.

    PubMed

    Rong, S S; Feng, M Y; Wang, N; Meng, H; Thomas, R; Fan, S; Wang, R; Wang, X; Tang, X; Liang, Y B

    2013-03-01

    To evaluate the association between early and late postoperative intraocular pressure (IOP) and determine if early postoperative IOP can predict the surgical outcome. A total of 165 consecutive patients with primary angle-closure glaucoma (PACG) undergoing primary mitomycin-C-augmented trabeculectomy underwent a comprehensive eye examination before surgery and were followed-up on days 1, 7, 14, and 30, and months 3, 6, 12, and 18. IOPs on days 1, 7, 14, and 30 were stratified into groups A (<10 mm Hg), B (≥10 and <15 mm Hg), C (≥15 and <20 mm Hg), and D (≥20 mm Hg). Differences between groups were analyzed using analysis of variance (ANOVA) and Fisher's exact test. Multivariable regression was used to exam the predictive ability of early IOP for final outcome. The mean age was 62.5±7.9 years and 41.21% (n=68) were males. Stratified by IOP on days 1, 7, 14, and 30, respectively, mean IOPs at month 18 were different among groups A, B, C, and D (ANOVA, P=0.047, P=0.033, P=0.008, and P<0.001, respectively). Once the IOPs were settled with interventions on day 7 a higher IOP level was associated with decreasing success rate under different outcome definitions, final IOP <15 mm Hg (Fisher's exact P=0.001) and <20 mm Hg (P=0.039) without medication. Multiple regression showed early IOP predicted final IOP independently from baseline variables. A cutoff value of 13.5 mm Hg on day 7 achieved an accuracy of 80.0 and 57.1% in predicting IOP<15 mm Hg without medication and failure after surgery, respectively. The IOP at 18 months following primary antifibrotic-augmented trabeculectomy in PACG patients is associated with and predicted by the postoperative IOPs at 1 month. Control of early IOP to 13.5 or less may provide better outcomes.

  12. Comparison of Risk Factor Profiles for Primary Open-Angle Glaucoma Subtypes Defined by Pattern of Visual Field Loss: A Prospective Study.

    PubMed

    Kang, Jae H; Loomis, Stephanie J; Rosner, Bernard A; Wiggs, Janey L; Pasquale, Louis R

    2015-04-01

    We explored whether risk factor associations differed by primary open-angle glaucoma (POAG) subtypes defined by visual field (VF) loss pattern (i.e., paracentral or peripheral). We included 77,157 women in the Nurses' Health Study (NHS) and 42,773 men in the Health Professionals Follow-up Study (HPFS 1986-2010), and incident medical record confirmed cases of paracentral (n = 440) and peripheral (n = 865) POAG subtypes. We evaluated African heritage, glaucoma family history, body mass index (BMI), mean arterial blood pressure, diabetes mellitus, physical activity, smoking, caffeine intake, and alcohol intake. We used competing risk Cox regression analyses modeling age as the metameter and stratified by age, cohort, and event type. We sequentially identified factors with the least significant differences in associations with POAG subtypes ("stepwise down" approach with P for heterogeneity [P-het] < 0.10 as threshold). Body mass index was more inversely associated with the POAG paracentral VF loss subtype than the peripheral VF loss subtype (per 10 kg/m2; hazard ratio [HR] = 0.67 [95% confidence interval (CI): 0.52, 0.86] versus HR = 0.93 [95% CI: 0.78, 1.10]; P-het = 0.03) as was smoking (per 10 pack-years; HR = 0.92 [95% CI: 0.87, 0.98] versus HR = 0.98 [95% CI: 0.94, 1.01]; P-het = 0.09). These findings were robust in sensitivity analyses using a "stepwise up" approach (identify factors that showed the most significant differences). Nonheterogeneous (P-het > 0.10) adverse associations with both POAG subtypes were observed with glaucoma family history, diabetes, African heritage, greater caffeine intake, and higher mean arterial pressure. These data indicate that POAG with early paracentral VF loss has distinct as well as common determinants compared with POAG with peripheral VF loss.

  13. Shotgun proteomics reveals specific modulated protein patterns in tears of patients with primary open angle glaucoma naïve to therapy.

    PubMed

    Pieragostino, Damiana; Agnifili, Luca; Fasanella, Vincenzo; D'Aguanno, Simona; Mastropasqua, Rodolfo; Di Ilio, Carmine; Sacchetta, Paolo; Urbani, Andrea; Del Boccio, Piero

    2013-06-01

    Primary open angle glaucoma (POAG) is one of the main causes of irreversible blindness worldwide. The pathogenesis of POAG is still unclear. Alteration and sclerosis of trabecular meshwork with changes in aqueous humor molecular composition seem to play the key role. Increased intraocular pressure is widely known to be the main risk factor for the onset and progression of the disease. Unfortunately, the early diagnosis of POAG still remains the main challenge. In order to provide insight into the patho-physiology of glaucoma, here we report a shotgun proteomics approach to tears of patients with POAG naïve to therapy. Our proteomics results showed 27 differential tear proteins in POAG vs. CTRL comparison (25 up regulated proteins in the POAG group and two unique proteins in the CTRL group), 16 of which were associated with inflammatory response, free radical scavenging, cell-to-cell signaling and interaction. Overall the protein modulation shown in POAG tears proves the involvement of biochemical networks linked to inflammation. Among all regulated proteins, a sub-group of 12 up-regulated proteins in naïve POAG patients were found to be down-regulated in medically controlled POAG patients treated with prostanoid analogues (PGA), as reported in our previous work (i.e., lipocalin-1, lysozyme C, lactotransferrin, proline-rich-protein 4, prolactin-inducible protein, zinc-alpha-2-glycoprotein, polymeric immunoglobulin receptor, cystatin S, Ig kappa chain C region, Ig alpha-2 chain C region, immunoglobulin J chain, Ig alpha-1 chain C region). In summary, our findings indicate that the POAG tears protein expression is a mixture of increased inflammatory proteins that could be potential biomarkers of the disease, and their regulation may be involved in the mechanism by which PGA are able to decrease the intraocular pressure in glaucoma patients.

  14. Open Experimentation on Phenomena of Chemical Reactions via the Learning Company Approach in Early Secondary Chemistry Education

    ERIC Educational Resources Information Center

    Beck, Katharina; Witteck, Torsten; Eilks, Ingo

    2010-01-01

    Presented is a case study on the implementation of open and inquiry-type experimentation in early German secondary chemistry education. The teaching strategy discussed follows the learning company approach. Originally adopted from vocational education, the learning company method is used to redirect lab-oriented classroom practice towards a more…

  15. Incidence of infection after early intramedullary nailing of open tibial shaft fractures stabilized with pinless external fixators

    PubMed Central

    Kulshrestha, Vikas

    2008-01-01

    Background: A major drawback of conventional fixator system is the penetration of fixator pins into the medullary canal. The pins create a direct link between the medullary cavity and outer environment, leading to higher infection rates on conversion to intramedullary nailing. This disadvantage is overcome by the AO pinless fixator, in which the trocar points are clamped onto the outer cortex without penetrating it. This study was designed to evaluate the role of AO pinless fixators in primary stabilization of open diaphyseal tibial fractures that received staged treatment because of delayed presentation or poor general condition. We also analyzed the rate of infection on early conversion to intramedullary nail. Materials and Methods: This study is a retrospective review of 30 open diaphyseal fractures of tibia, which were managed with primary stabilization with pinless fixator and early exchange nailing. Outcome was evaluated in terms of fracture union and rate of residual infection. The data were compared with that available in the literature. Results: All the cases were followed up for a period of 2 years. The study includes Gustilo type 1 (n=10), 14 Gustilo type 2 (n=14), and type3 (n=6) cases. 6 cases (20%) had clamp site infection, 2 cases (6.7%) had deep infection, and in 28 cases (93%) the fracture healed and consolidated well. Conclusion: This study has highlighted the valuable role of pinless external fixator in the management of open tibial fractures in terms of safety and ease of application as well as the advantage of early conversion to intramedullary implant without the risk of deep infection. PMID:19753227

  16. Prospective Study of Oral Health and Risk of Primary Open-Angle Glaucoma in Men: Data from the Health Professionals Follow-up Study.

    PubMed

    Pasquale, Louis R; Hyman, Leslie; Wiggs, Janey L; Rosner, Bernard A; Joshipura, Kaumudi; McEvoy, Mark; McPherson, Zachary E; Danias, John; Kang, Jae H

    2016-11-01

    Tooth loss or periodontal disease is associated with systemic endothelial dysfunction, which has been implicated in primary open-angle glaucoma (POAG). The relationship between oral health and POAG has received limited attention. Thus, we evaluated the association between oral health history and risk of POAG and POAG subtypes. Prospective cohort study. Health Professionals Follow-up Study participants (40 536 men) followed biennially from 1986 to 2012. At each 2-year risk period, eligible participants were aged 40+ years, were free of POAG, and reported eye examinations. By using validated questions, we updated participants' status on number of natural teeth, teeth lost, periodontal disease with bone loss, and root canal treatments. During follow-up, 485 incident cases of POAG were confirmed with medical records and classified into subtypes defined by intraocular pressure (IOP; ≥ or <22 mmHg) or visual field (VF) loss pattern at diagnosis (peripheral loss only or early paracentral loss). Multivariable relative risks (MVRRs) and 95% confidence intervals (CIs) were estimated. Number of natural teeth, periodontal disease, and root canal treatment were not associated with POAG. However, compared with no report of tooth loss, a report of losing teeth within the past 2 years was associated with a 1.45-fold increased risk of POAG (95% CI, 1.06-1.97); in particular, a report within the past 2 years of both losing teeth and having a prevalent diagnosis of periodontal disease was associated with a 1.85-fold increased risk of POAG (95% CI, 1.07-3.18). The associations with recent tooth loss were not significantly different for the POAG subtypes (P for heterogeneity ≥0.36), although associations were strongest in relation to the POAG subtypes with IOP <22 mmHg (MVRR, 1.93; 95% CI, 1.09-3.43) and early paracentral VF loss (MVRR, 2.27; 95% CI, 1.32-3.88). Although the number of natural teeth was not associated with risk of POAG, recent tooth loss was associated with an

  17. [Cholecystectomy in the elderly: early results of open versus laparoscopic approach].

    PubMed

    Régo, Ronaldo Elias Carnut; de Campos, Tércio; de Moricz, André; Silva, Rodrigo Altenfelder; Pacheco Júnior, Adhemar Monteiro

    2003-01-01

    The rise of elderly population is due to the improvement of life expectancy. The biliary lithiasis is the most common condition requiring intra-abdominal surgery. Half of these patients sustain associated diseases and frequently develops acute and complicated forms of cholelithiasis. Therefore, cholecystectomy is indicated for patients with chronic symptomatic disease. During a long period open cholecystectomy has been practiced, with low complications and mortality rates. Videolaparoscopy has been recently proposed as an option in these cases, however, few studies compared its advantages over open cholecystectomy for elderly patients. To access the early results of the surgical treatment for cholelithiasis in the elderly submitted to an open or laparoscopic cholecystectomy. retrospective study with 246 patients > 65 years old, who underwent elective cholecystectomy through a subcostal incision (group I) or laparoscopic approach (group II). We employed Student's t test and Spearman's correlation for statistical analysis, considering p < 0,05 as significant. A hundred and twenty patients were arranged in group I and 126 in group II. Associated diseases were present in 155 cases (63). There were no differences between the groups regarding both the distribution of comorbid conditions. Conversion was evaluated in 10 patients (8.3%). The mean operative time was 133 minutes in group I and 112 minutes in group II (p=0.001). The mean hospital stay in group I was 3,3 days and in group II was 3.2 days p=0.698. Thirteen patients in each group developed complications: group I (10.8%) and group II (10.3%) p=0,896. There was no statistis significance in complication rate related to gender, age, associated diseases and ASA when the both groups were compared. There were two deaths, both in group II, although the mortality rate was not statiscally significant between the groups (p=0.158). Both open and laparoscopic cholecystectomy can be practiced in the elderly with low and

  18. Association of Bruch's membrane opening and optic disc morphology to axial length and visual field defects in eyes with primary open-angle glaucoma.

    PubMed

    Nakanishi, Hideo; Suda, Kenji; Yoshikawa, Munemitsu; Akagi, Tadamichi; Kameda, Takanori; Ikeda, Hanako Ohashi; Yokota, Satoshi; Kurimoto, Yasuo; Tsujikawa, Akitaka

    2018-03-01

    To examine the morphology of Bruch's membrane opening (BMO), optic disc, and peripapillary atrophy (PPA) by scanning laser ophthalmoscopy (SLO) and spectral-domain optical coherence tomography (SD-OCT), and to determine their association with the axial length and visual field defects. This was a cross-sectional study of 94 eyes of 56 subjects; 77 eyes were diagnosed with primary open-angle glaucoma and 17 eyes as normal. The margins of the optic disc were determined in the SLO images, and that of the BMO in the SD-OCT images. The ovality and area of the BMO and the optic disc were measured. The beta and gamma-PPA areas were also measured. The association of each parameter with the axial length and the mean deviation (MD) of the visual field tests was determined by generalized estimating equations (GEEs). The optic disc ovality was associated with the axial length and the MD (β = -0.47, P = 7.6 × 10 -4 and β = 0.12, P = 0.040). The BMO ovality was not significantly associated with the axial length and the MD. The BMO area was associated with the axial length (β = 0.30, P = 0.029). A larger BMO area was associated with a thinner BMO-based neuroretinal rim width (BMO-MRW) after adjustments for the MD (β = -0.30, P = 2.1 × 10 -4 ). The beta- and gamma-PPA areas were associated with the axial length (β = 0.50, P = 7.4 × 10 -5 and β = 0.62, P = 4.2 × 10 -6 ). The optic disc ovality was associated with both the axial length and MD, whereas BMO ovality was not. Attention should be paid to the influence of the axial length-related enlargement of the BMO.

  19. Development and initial validation of the Classification of Early-Onset Scoliosis (C-EOS).

    PubMed

    Williams, Brendan A; Matsumoto, Hiroko; McCalla, Daren J; Akbarnia, Behrooz A; Blakemore, Laurel C; Betz, Randal R; Flynn, John M; Johnston, Charles E; McCarthy, Richard E; Roye, David P; Skaggs, David L; Smith, John T; Snyder, Brian D; Sponseller, Paul D; Sturm, Peter F; Thompson, George H; Yazici, Muharrem; Vitale, Michael G

    2014-08-20

    Early-onset scoliosis is a heterogeneous condition, with highly variable manifestations and natural history. No standardized classification system exists to describe and group patients, to guide optimal care, or to prognosticate outcomes within this population. A classification system for early-onset scoliosis is thus a necessary prerequisite to the timely evolution of care of these patients. Fifteen experienced surgeons participated in a nominal group technique designed to achieve a consensus-based classification system for early-onset scoliosis. A comprehensive list of factors important in managing early-onset scoliosis was generated using a standardized literature review, semi-structured interviews, and open forum discussion. Three group meetings and two rounds of surveying guided the selection of classification components, subgroupings, and cut-points. Initial validation of the system was conducted using an interobserver reliability assessment based on the classification of a series of thirty cases. Nominal group technique was used to identify three core variables (major curve angle, etiology, and kyphosis) with high group content validity scores. Age and curve progression ranked slightly lower. Participants evaluated the cases of thirty patients with early-onset scoliosis for reliability testing. The mean kappa value for etiology (0.64) was substantial, while the mean kappa values for major curve angle (0.95) and kyphosis (0.93) indicated almost perfect agreement. The final classification consisted of a continuous age prefix, etiology (congenital or structural, neuromuscular, syndromic, and idiopathic), major curve angle (1, 2, 3, or 4), and kyphosis (-, N, or +) variables, and an optional progression modifier (P0, P1, or P2). Utilizing formal consensus-building methods in a large group of surgeons experienced in treating early-onset scoliosis, a novel classification system for early-onset scoliosis was developed with all core components demonstrating

  20. Effects of seed weight and rate of emergence on early growth of open-pollinated Douglas-fir families.

    Treesearch

    J.B. St. Clair; W.T. Adams

    1991-01-01

    Seed weight, time of emergence, and three measures of seedling size were recorded for 39 open-pollinated Douglas-fir (Pseudotsuga menziesii var. menziesii[Mirb.] Franco) families in order to assess family variation in seed weight and emergence, and the influence of these seed traits on early growth. Families were planted both...

  1. Some dissociating factors in the analysis of structural and functional progressive damage in open-angle glaucoma.

    PubMed

    Hudson, C J W; Kim, L S; Hancock, S A; Cunliffe, I A; Wild, J M

    2007-05-01

    To identify the presence, and origin, of any "dissociating factors" inherent to the techniques for evaluating progression that mask the relationship between structural and functional progression in open-angle glaucoma (OAG). 23 patients (14 with OAG and 9 with ocular hypertension (OHT)) who had received serial Heidelberg Retina Tomograph (HRT II) and Humphrey Field Analyser (HFA) examinations for >or=5 years (mean 78.4 months (SD 9.5), range 60-101 months) were identified. Evidence of progressive disease was retrospectively evaluated in one eye of each patient using the Topographic Change Analysis (TCA) and Glaucoma Progression Analysis (GPA) for the HRT II and HFA, respectively. Six patients were stable by both techniques; four exhibited both structural and functional progression; seven exhibited structural progression, only, and six showed functional progression, only. Three types of dissociating factors were identified. TCA failed to identify progressive structural damage in the presence of advanced optic nerve head damage. GPA failed to identify progressive functional damage at stimulus locations, with sensitivities exhibiting test-retest variability beyond the maximum stimulus luminance of the perimeter, and where a perimetric learning effect was apparent. The three dissociating factors accounted for nine of the 13 patients who exhibited a lack of concordance between structural and functional progressive damage.

  2. Comparison of optical coherence tomography findings and visual field changes in patients with primary open-angle glaucoma and amyotrophic lateral sclerosis.

    PubMed

    Liu, Ziyuan; Wang, Hongli; Fan, Dongsheng; Wang, Wei

    2018-02-01

    Recent studies revealing genetic connection of primary open angle glaucoma (POAG) and amyotrophic lateral sclerosis (ALS) have received particular attention. Exploring the evidence for common pathogenesis of these two progressive neurological disorders may assist in understanding the mechanism and searching for new treatment. Retinal nerve fiber layer (RNFL) defect and corresponding visual field (VF) impairment are well known neuropathy signs in glaucoma. In our study, thickness of certain retinal layer in ALS patients was analyzed to detect ganglion cell's soma and axon, and for first time visual field was examined for ALS. The correlation of retinal involvement and ALS progression were also investigated. The results were compared with those of POAG. The study may provide new knowledge for these two neurodegenerative diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. The association between primary open-angle glaucoma and fall: an observational study.

    PubMed

    Tanabe, Sachiko; Yuki, Kenya; Ozeki, Naoki; Shiba, Daisuke; Tsubota, Kazuo

    2012-01-01

    Falls are among the most serious public health concerns for the elderly. Information conveyed via the visual sense is relevant to postural balance and movement, and proper visual function is essential to avoid falls. Here we investigated the prevalence of injurious falls among patients with primary open-angle glaucoma (POAG) who were more than 45 years old, compared with comparably aged healthy subjects. This is a cross-sectional study. Consecutive patients who visited the Tanabe Eye Clinic, Yamanashi, Japan between January 1 and March 30, 2009 were screened for eligibility by ophthalmic examination. A total of 117 control subjects (77 men, 40 women; aged 60.2 ± 7.5 years) who were free of ocular disease and 101 POAG patients (58 men, 43 women; aged 62.3 ± 8.7 years) were consecutively enrolled. Participants answered a questionnaire on injurious fall experience during the previous 10 years. The prevalence of injurious fall in subjects with POAG versus healthy controls was examined with Fisher's exact test. Adjusted odds ratios and 95% confidence intervals were estimated with logistic regression models for the subjects with POAG (factors: age, gender, mean deviation in the better eye or worse eye). The self-reported prevalence of injurious fall was 0.9% (1/117) in the control group and 6.9% (7/101) in the POAG group. The association between injurious fall and POAG was statistically significant (P = 0.026, Fisher's exact test). Within the POAG patients, the group reporting falls was significantly older and had a lower BMI, worse BCVA, and worse mean deviation in both the better and worse eye than the group reporting no falls. Worse mean deviation in the eye with the better visual field (odds ratios 0.75; 95% confidence intervals: 0.57 to 0.99; P = 0.036) was a significant risk factor for injurious falls in subjects with POAG. POAG was significantly associated with injurious falls.

  4. The long-term outcomes of four alternative treatment strategies for primary open-angle glaucoma.

    PubMed

    van Gestel, Aukje; Webers, Carroll A; Severens, Johan L; Beckers, Henny J; Jansonius, Nomdo M; Hendrikse, Fred; Schouten, Jan S

    2012-02-01

    To evaluate the long-term effects and costs of four treatment strategies for primary open-angle glaucoma compared to usual care. Cost-effectiveness analyses with a lifelong horizon were made from a societal perspective. Data were generated with a patient-level model based on discrete event simulation. The model structure and parameter estimates were based on literature, particularly clinical studies on the natural course of glaucoma and the effect of treatment. We simulated heterogeneous cohorts of 3000 patients and explored the impact of uncertainty with sensitivity analyses. The incremental cost-effectiveness ratio (ICER) of initial treatment with a prostaglandin analogue compared with a β-blocker was €12.931 per quality-adjusted life year (QALY) gained. A low initial target pressure (15 mmHg) resulted in 0.115 QALYs gained and €1550 saved compared to a gradual decrease from 21 to 15 mmHg upon progression. Visual field (VF) measurements every 6 rather than 12 months lead to health gains at increased costs (ICER €173,486 per QALY gained), whereas measurements every 24 months lead to health losses at reduced costs (ICER €21,516 per QALY lost). All treatment strategies were dominant over 'withholding treatment'. From a cost-effectiveness point of view, it seems advantageous to aim for a low intraocular pressure in all glaucoma patients. The feasibility of this strategy should therefore be investigated. Additionally, the cost-effectiveness outcomes of initiating monotherapy with a prostaglandin analogue and reducing the frequency of VF testing may be acceptable. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  5. Decreased paraoxonase1 activity and increased malondialdehyde and oxidative DNA damage levels in primary open angle glaucoma

    PubMed Central

    Mumcu, Ugur Yilmaz; Kocer, Ibrahim; Ates, Orhan; Alp, H. Hakan

    2016-01-01

    To investigate the malondialdehyde (MDA) levels, paraoxonase1 (PON1) activity and 8-hydroxy 2-deoxyguanosine (8-OHdG) levels in the primary open angle glaucoma (POAG) patient. Blood samples from 52 healthy individuals and 53 patients with POAG were analyzed for MDA and 8-OHdG by HPLC (high-performance liquid chromatography) and PON1 by spectrophotometry. The data obtained were analyzed statistically. MDA levels were 10.46±8.4 and 4.70±1.79 µmol; PON1 levels were 121±39.55 and 161.62±60.22 U/mL; and 8-OHdG values were 1.32±0.53/106 dG and 0.47±0.27/106 dG in the POAG patients and the control group, respectively. The difference was significant in MDA levels, 8-OHdG levels and PON1 activity in POAG patients in comparison with controls (P<0.001). We concluded that the observed increase in MDA and 8-OHdG levels may be correlated with decreased PON1 activity. Oxidative stress plays an important role in glaucoma development. PMID:27803873

  6. Comparative study of the retinal nerve fibre layer thickness performed with optical coherence tomography and GDx scanning laser polarimetry in patients with primary open-angle glaucoma.

    PubMed

    Wasyluk, Jaromir T; Jankowska-Lech, Irmina; Terelak-Borys, Barbara; Grabska-Liberek, Iwona

    2012-03-01

    We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. Study subjects had advanced primary open-angle glaucoma, previously treated conservatively, diagnosed and confirmed by additional examinations (visual field, ophthalmoscopy of optic nerve, gonioscopy), A total of 10 patients were enrolled (9 women and 1 man), aged 18-70 years of age. Nineteen eyes with advanced glaucomatous neuropathy were examined. 1) Performing a threshold perimetry Octopus, G2 strategy and ophthalmoscopy of optic nerve to confirm the presence of advanced primary open-angle glaucoma; 2) performing a GDx VCC scanning laser polarimetry of retinal nerve fibre layer; 3) measuring the retinal nerve fibre layer thickness with 3 different optical coherence tomographs. The parameters of the retinal nerve fibre layer thickness are highly correlated between the GDx and OCT Stratus and 3D OCT-1000 devices in mean retinal nerve fibre layer thickness, retinal nerve fibre layer thickness in the upper sector, and correlation of NFI (GDx) with mean retinal nerve fibre layer thickness in OCT examinations. Absolute values of the retinal nerve fibre layer thickness (measured in µm) differ significantly between GDx and all OCT devices. Examination with OCT devices is a sensitive diagnostic method of glaucoma, with good correlation with the results of GDx scanning laser polarimetry of the patients.

  7. Factors associated with postoperative C5 palsy after expansive open-door laminoplasty: retrospective cohort study using multivariable analysis.

    PubMed

    Tsuji, Takashi; Matsumoto, Morio; Nakamura, Masaya; Ishii, Ken; Fujita, Nobuyuki; Chiba, Kazuhiro; Watanabe, Kota

    2017-09-01

    The aim of the present study was to investigate the factors associated with C5 palsy by focusing on radiological parameters using multivariable analysis. The authors retrospectively assessed 190 patients with cervical spondylotic myelopathy treated by open-door laminoplasty. Four radiographic parameters-the number of expanded lamina, C3-C7 angle, lamina open angle and space anterior to the spinal cord-were evaluated to clarify the factors associated with C5 palsy. Of the 190 patients, 11 developed C5 palsy, giving an overall incidence of 5.8%. Although the number of expanded lamina, lamina open angle and space anterior to the spinal cord were significantly larger in C5 palsy group than those in non-palsy group, a multiple logistic regression analysis revealed that only the space anterior to the spinal cord (odds ratio 2.60) was a significant independent factor associated with C5 palsy. A multiple linear regression analysis indicated that the lamina open angle was associated with the space anterior to the spinal cord and the analysis identified the following equation: space anterior to the spinal cord (mm) = 1.54 + 0.09 × lamina open angle (degree). A cut-off value of 53.5° for the lamina open angle predicted the development of C5 palsy with a sensitivity of 72.7% and a specificity of 83.2%. The larger postoperative space anterior to the spinal cord, which was associated with the lamina open angle, was positively correlated with the higher incidence of C5 palsy.

  8. Axial Myopia Is Associated with Visual Field Prognosis of Primary Open-Angle Glaucoma

    PubMed Central

    Qiu, Chen; Qian, Shaohong; Sun, Xinghuai; Zhou, Chuandi; Meng, Fanrong

    2015-01-01

    Purpose To identify whether myopia was associated with the visual field (VF) progression of primary open-angle glaucoma (POAG). Methods A total of 270 eyes of 270 POAG followed up for more than 3 years with ≥9 reliable VFs by Octopus perimetry were retrospectively reviewed. Myopia was divided into: mild myopia (-2.99 diopter [D], 0), moderate myopia (-5.99, 3.00 D), marked myopia (-9.00, -6.00 D) and non-myopia (0 D or more). An annual change in the mean defect (MD) slope >0.22 dB/y and 0.30 dB/y was defined as fast progression, respectively. Logistic regression was performed to determine prognostic factors for VF progression. Results For the cutoff threshold at 0.22 dB/y, logistic regression showed that vertical cup-to-disk ratio (VCDR; p = 0.004) and the extent of myopia (p = 0.002) were statistically significant. When logistic regression was repeated after excluding the extent of myopia, axial length (AL; p = 0.008, odds ratio [OR] = 0.796) reached significance, as did VCDR (p = 0.001). Compared to eyes with AL≤23 mm, the OR values were 0.334 (p = 0.059), 0.309 (p = 0.044), 0.266 (p = 0.019), 0.260 (p = 0.018), respectively, for 23 26 mm. The significance of vertical cup-to-disk ratio of (p = 0.004) and the extent of myopia (p = 0.008) did not change for the cutoff threshold at 0.30dB/y. Conclusions VCDR and myopia were associated with VF prognosis of POAG. Axial myopia may be a protective factor against VF progression. PMID:26214313

  9. Discovery and Functional Annotation of SIX6 Variants in Primary Open-Angle Glaucoma

    PubMed Central

    Allingham, R. Rand; Whigham, Benjamin T.; Havens, Shane; Garrett, Melanie E.; Qiao, Chunyan; Katsanis, Nicholas; Wiggs, Janey L.; Pasquale, Louis R.; Ashley-Koch, Allison; Oh, Edwin C.; Hauser, Michael A.

    2014-01-01

    Glaucoma is a leading cause of blindness worldwide. Primary open-angle glaucoma (POAG) is the most common subtype and is a complex trait with multigenic inheritance. Genome-wide association studies have previously identified a significant association between POAG and the SIX6 locus (rs10483727, odds ratio (OR) = 1.32, p = 3.87×10−11). SIX6 plays a role in ocular development and has been associated with the morphology of the optic nerve. We sequenced the SIX6 coding and regulatory regions in 262 POAG cases and 256 controls and identified six nonsynonymous coding variants, including five rare and one common variant, Asn141His (rs33912345), which was associated significantly with POAG (OR = 1.27, p = 4.2×10−10) in the NEIGHBOR/GLAUGEN datasets. These variants were tested in an in vivo Danio rerio (zebrafish) complementation assay to evaluate ocular metrics such as eye size and optic nerve structure. Five variants, found primarily in POAG cases, were hypomorphic or null, while the sixth variant, found only in controls, was benign. One variant in the SIX6 enhancer increased expression of SIX6 and disrupted its regulation. Finally, to our knowledge for the first time, we have identified a clinical feature in POAG patients that appears to be dependent upon SIX6 genotype: patients who are homozygous for the SIX6 risk allele (His141) have a statistically thinner retinal nerve fiber layer than patients homozygous for the SIX6 non-risk allele (Asn141). Our results, in combination with previous SIX6 work, lead us to hypothesize that SIX6 risk variants disrupt the development of the neural retina, leading to a reduced number of retinal ganglion cells, thereby increasing the risk of glaucoma-associated vision loss. PMID:24875647

  10. A Microbeam Small-Angle X-ray Scattering Study on Enamel Crystallites in Subsurface Lesion

    NASA Astrophysics Data System (ADS)

    Yagi, N.; Ohta, N.; Matsuo, T.; Tanaka, T.; Terada, Y.; Kamasaka, H.; Kometani, T.

    2010-10-01

    The early caries lesion in bovine tooth enamel was studied by two different X-ray diffraction systems at the SPring-8 third generation synchrotron radiation facility. Both allowed us simultaneous measurement of the small and large angle regions. The beam size was 6μm at BL40XU and 50μm at BL45XU. The small-angle scattering from voids in the hydroxyapatite crystallites and the wide-angle diffraction from the hydroxyapatite crystals were observed simultaneously. At BL40XU an X-ray image intensifier was used for the small-angle and a CMOS flatpanel detector for the large-angle region. At BL45XU, a large-area CCD detector was used to cover both regions. A linear microbeam scan at BL40XU showed a detailed distribution of voids and crystals and made it possible to examine the structural details in the lesion. The two-dimensional scan at BL45XU showed distribution of voids and crystals in a wider region in the enamel. The simultaneous small- and wide-angle measurement with a microbeam is a powerful tool to elucidate the mechanisms of demineralization and remineralization in the early caries lesion.

  11. Proximal Tibia Medial Biplanar Retrotubercle Open Wedge Osteotomy for Varus Knees with Medial Gonarthrosis

    PubMed Central

    Türkmen, İsmail; Esenkaya, İrfan; Ünay, Koray; Türkmensoy, Fatih; Özkut, Afşar Timuçin

    2014-01-01

    Objectives: The purpose of this study is to evaluate the early results of proximal tibia medial biplanar retrotubercle open wedge osteotomy for varus gonarthrosis and compare the results with the literatüre. Methods: The results of proximal tibia medial biplanar retrotubercle open wedge osteotomy for 23 knees of 22 patients with medial gonarthrosis were evaluated clinically and radiologically. Results: Twenty of the patients were female and two were male. Mean age of the patients was 56.24; mean boy mass index was 31.95 and preoperative HSS (Hospital for Special Surgery) score was 68.7. Mean tibiofemoral axis was 186.39° and mean Insall-Salvatti index value was 1.04 preoperatively. Mean follow up period was 30.19 months. Mean HSS score was 86.48, femorotibial anatomic axis angle was 175° and Insall-Salvati index value 1.06 during the last follow-up. The improvement of the HSS score and the femorotibial anatomic axis angle was statistically significant. However, the change in Insall Salvati index values was statistically insignificant. Nonfatal pulmonary embolus in 1 patient, and deep vein thrombosis that occured one year after the procedure in 1 patient, rhabdomyolysis in 1 patient and loss of correction (relapse) in 1 patient were encountered as complications. Conclusion: Our results show that proximal tibia medial biplanar retrotubercle open wedge osteotomy improves the frontal and sagittal plane deformities without changing the patellar tendon length. Hence, possible patellofemoral problems are prevented and the clinical results are improved.

  12. High Grazing Angle Sea-Clutter Literature Review

    DTIC Science & Technology

    2013-03-01

    Optimal and sub-optimal detection .................................................................... 37 7.3 Polarimetry ... polarimetry for target detection from high grazing angles. UNCLASSIFIED DSTO-GD-0736 UNCLASSIFIED 36 7.1 Parametric modelling There have not been...relationships were also found to be intrinsically related to Gaussian detection counterparts. 7.3 Polarimetry Early studies by Stacy et al. [45, 46] and

  13. Effects of early environmental enrichment upon open-field behavior and timidity in the domestic chick.

    PubMed

    Jones, R B

    1982-03-01

    Early environmental enrichment was evaluated by its effect on the behavior of 7-day-old male and female domestic chicks in an open field or novel environment and in a hole-in-the-wall test of timidity. The chicks were housed in same-sex groups of 10. The bare environments contained wood litter, food, and water, whereas the enriched boxes also contained various objects. In the open field, immobility was lower while feeding, walking, jumping and vocalization were higher in the enriched birds than in those reared in the bare environment. Enrichment also decreased emergence latencies in the hole-in-the-wall box. The increased stimulation provided by environmental enrichment may decrease fearfulness in subsequent fear-inducing situations and may enhance the ability of animals to adapt to novelty.

  14. Improvement in Creatinine Clearance after Open Heart Surgery in Infants as an Early Indicator of Surgical Success.

    PubMed

    Dagan, Amit; Dagan, Ovadia

    2016-12-01

    Early surgical correction of congenital heart malformations in neonates and small infants may be complicated by acute kidney injury (AKI), which is associated with higher morbidity and mortality rates, especially in patients who require dialysis. Glomerular filtration rate (GFR) is considered the best measurement of renal function which, in neonates and infants, is highly dependent on heart function. To determine whether measurements of creatinine clearance after open heart surgery in neonates and young infants can serve as an early indicator of surgical success or AKI. We conducted a prospective observational study in 19 neonates and small infants (body weight < 5 kg) scheduled for open heart surgery with cardiopulmonary bypass. Urine collection measurement of creatinine clearance and albumin excretion was performed before and during surgery and four times during 48 hours after surgery. Mean creatinine clearance was lowest during surgery (25.2 ± 4. ml/min/1.73 m2) and increased significantly in the first 16 hours post-surgery (45.7 ± 6.3 ml/min/1.73 m2). A similar pattern was noted for urine albumin which was highest during surgery (203 ± 31 µg/min) and lowest (93 ± 20 µg/min) 48 hours post-surgery. AKI occurred in four patients, and two patients even required dialysis. All six showed a decline in creatinine clearance and an increase in urine albumin between 8 and 16 hours post-surgery. In neonates and small infants undergoing open heart surgery, a significant improvement in creatinine clearance in the first 16 hours postoperatively is indicative of a good surgical outcome. This finding has important implications for the early evaluation and treatment of patients in the intensive care unit on the first day post-surgery.

  15. Margaret and Rachel McMillan: Their Influences on Open-Air Nursery Education and Early Years Teacher Education

    ERIC Educational Resources Information Center

    Liebovich, Betty

    2014-01-01

    Rachel and Margaret McMillan created an open-air nursery in Deptford, London that has influenced early years education for 100 years. Their vision for young children living in poverty and deprivation to have access to fresh air through outdoor learning, nutritious meals, and an enriching environment to explore and develop has been embraced and…

  16. Developing an Open Source, Reusable Platform for Distributed Collaborative Information Management in the Early Detection Research Network

    NASA Technical Reports Server (NTRS)

    Hart, Andrew F.; Verma, Rishi; Mattmann, Chris A.; Crichton, Daniel J.; Kelly, Sean; Kincaid, Heather; Hughes, Steven; Ramirez, Paul; Goodale, Cameron; Anton, Kristen; hide

    2012-01-01

    For the past decade, the NASA Jet Propulsion Laboratory, in collaboration with Dartmouth University has served as the center for informatics for the Early Detection Research Network (EDRN). The EDRN is a multi-institution research effort funded by the U.S. National Cancer Institute (NCI) and tasked with identifying and validating biomarkers for the early detection of cancer. As the distributed network has grown, increasingly formal processes have been developed for the acquisition, curation, storage, and dissemination of heterogeneous research information assets, and an informatics infrastructure has emerged. In this paper we discuss the evolution of EDRN informatics, its success as a mechanism for distributed information integration, and the potential sustainability and reuse benefits of emerging efforts to make the platform components themselves open source. We describe our experience transitioning a large closed-source software system to a community driven, open source project at the Apache Software Foundation, and point to lessons learned that will guide our present efforts to promote the reuse of the EDRN informatics infrastructure by a broader community.

  17. The effect of HIV on early wound healing in open fractures treated with internal and external fixation.

    PubMed

    Aird, J; Noor, S; Lavy, C; Rollinson, P

    2011-05-01

    There are 33 million people worldwide currently infected with human immunodeficiency virus (HIV). This complex disease affects many of the processes involved in wound and fracture healing, and there is little evidence available to guide the management of open fractures in these patients. Fears of acute and delayed infection often inhibit the use of fixation, which may be the most effective way of achieving union. This study compared fixation of open fractures in HIV-positive and -negative patients in South Africa, a country with very high rates of both HIV and high-energy trauma. A total of 133 patients (33 HIV-positive) with 135 open fractures fulfilled the inclusion criteria. This cohort is three times larger than in any similar previously published study. The results suggest that HIV is not a contraindication to internal or external fixation of open fractures in this population, as HIV is not a significant risk factor for acute wound/implant infection. However, subgroup analysis of grade I open fractures in patients with advanced HIV and a low CD4 count (< 350) showed an increased risk of infection; we suggest that grade I open fractures in patients with advanced HIV should be treated by early debridement followed by fixation at an appropriate time.

  18. Early deprivation increases high-leaning behavior, a novel anxiety-like behavior, in the open field test in rats.

    PubMed

    Kuniishi, Hiroshi; Ichisaka, Satoshi; Yamamoto, Miki; Ikubo, Natsuko; Matsuda, Sae; Futora, Eri; Harada, Riho; Ishihara, Kohei; Hata, Yoshio

    2017-10-01

    The open field test is one of the most popular ethological tests to assess anxiety-like behavior in rodents. In the present study, we examined the effect of early deprivation (ED), a model of early life stress, on anxiety-like behavior in rats. In ED animals, we failed to find significant changes in the time spent in the center or thigmotaxis area of the open field, the common indexes of anxiety-like behavior. However, we found a significant increase in high-leaning behavior in which animals lean against the wall standing on their hindlimbs while touching the wall with their forepaws at a high position. The high-leaning behavior was decreased by treatment with an anxiolytic, diazepam, and it was increased under intense illumination as observed in the center activity. In addition, we compared the high-leaning behavior and center activity under various illumination intensities and found that the high-leaning behavior is more sensitive to illumination intensity than the center activity in the particular illumination range. These results suggest that the high-leaning behavior is a novel anxiety-like behavior in the open field test that can complement the center activity to assess the anxiety state of rats. Copyright © 2017 Elsevier Ireland Ltd and Japan Neuroscience Society. All rights reserved.

  19. A new technique for quantifying symmetry and opening angles in quartz c-axis pole figures: Implications for interpreting the kinematic and thermal properties of rocks

    NASA Astrophysics Data System (ADS)

    Hunter, N. J. R.; Weinberg, R. F.; Wilson, C. J. L.; Law, R. D.

    2018-07-01

    Variations in flow kinematics influence the type of crystallographic preferred orientations (CPOs) in plastically deformed quartz, yet we currently lack a robust means of quantifying the diagnostic symmetries that develop in the c-axis (0001) pole figure. In this contribution, we demonstrate how the symmetry of common c-axis topologies may be quantified by analysing the intensity distribution across a line transect of the pole figure margin. A symmetry value (S) measures the relative difference in intensities between marginal girdle maxima in the pole figure, and thus the degree to which the pole figure defines orthorhombic or monoclinic end member symmetries. This provides a semi-quantitative depiction of whether the rocks underwent coaxial or non-coaxial flow, respectively, and may subsequently be used to quantify other topological properties, such as the opening angle of girdle maxima. The open source Matlab® toolbox MTEX is used to quantify pole figure symmetries in quartzite samples from the Main Central Thrust (NW Himalaya) and the Moine Thrust (NW Scotland).

  20. Plasminogen activator inhibitor-1 4G/5G gene polymorphism and primary open-angle glaucoma

    PubMed Central

    Weger, Martin; Faschinger, Christoph; Schmut, Otto; Renner, Wilfried

    2008-01-01

    Purpose Alterations of the plasmin system have been suggested to participate in the multifactorial pathogenesis of primary open-angle glaucoma (POAG). The main physiological inhibitor of the plasmin system is plasminogen activator inhibitor-1 (PAI-1), which leads to decreased degradation of extracellular material. Interestingly, elevated PAI-1 levels in the aqueous humor of patients with POAG have been reported. A common polymorphism within the promoter region (PAI-1 4G/5G) has previously been shown to reduce the gene transcription rate of PAI-1. The purpose of the present study was to investigate a hypothesized association between PAI-1 4G/5G and the presence of POAG in a Caucasian population. Methods The present case-control study comprised 212 unrelated patients with POAG and 212 healthy control subjects, matched for age and sex. Genotyping of PAI-1 4G/5G polymorphisms was done using polymerase chain reaction. Results Allelic frequencies and genotype distributions of PAI-1 4G/5G did not significantly differ between patients with POAG and control subjects (PAI-1 4G/5G: 29.7% versus 29.7%). Presence of the PAI-1 4G-allele was associated with a nonsignificant odds ratio of 0.98 (95% confidence interval: 0.74–1.30) for POAG. Conclusions Our data suggest that PAI-1 4G/5G itself is unlikely to be a major risk factor among Caucasian patients with POAG. PMID:18615155

  1. Neurovascular structures of the mandibular angle and condyle: a comprehensive anatomical review.

    PubMed

    Yang, Hun-Mu; Won, Sung-Yoon; Kim, Hee-Jin; Hu, Kyung-Seok

    2015-11-01

    Various surgical interventions including esthetic surgery, salivary gland excision, and open reduction of fracture have been performed in the area around the mandibular angle and condyle. This study aimed to comprehensively review the anatomy of the neurovascular structures on the angle and condyle with recent anatomic and clinical research. We provide detailed information about the branching and distributing patterns of the neurovascular structures at the mandibular angle and condyle, with reported data of measurements and proportions from previous anatomical and clinical research. Our report should serve to help practitioners gain a better understanding of the area in order or reduce potential complications during local procedures. Reckless manipulation during mandibular angle reduction could mutilate arterial branches, not only from the facial artery, but also from the external carotid artery. The transverse facial artery and superficial temporal artery could be damaged during approach and incision in the condylar area. The marginal mandibular branch of the facial nerve can be easily damaged during submandibular gland excision or facial rejuvenation treatment. The main trunk of the facial nerve and its upper and lower distinct divisions have been damaged during parotidectomy, rhytidectomy, and open reductions of condylar fractures. By revisiting the information in the present study, surgeons will be able to more accurately prevent procedure-related complications, such as iatrogenic vascular accidents on the mandibular angle and condyle, complete and partial facial palsy, gustatory sweating (Frey syndrome), and traumatic neuroma after parotidectomy.

  2. Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes.

    PubMed

    Nolan, Winifred P; See, Jovina L; Chew, Paul T K; Friedman, David S; Smith, Scott D; Radhakrishnan, Sunita; Zheng, Ce; Foster, Paul J; Aung, Tin

    2007-01-01

    To evaluate noncontact anterior segment optical coherence technology (AS-OCT) as a qualitative method of imaging the anterior chamber angle and to determine its ability to detect primary angle closure when compared with gonioscopy in Asian subjects. Prospective observational case series. Two hundred three subjects were recruited from glaucoma clinics in Singapore with diagnoses of primary angle closure, primary open-angle glaucoma, ocular hypertension, or cataract. Both eyes (if eligible) of each patient were included in the study. Exclusion criteria were pseudophakia or previous glaucoma surgery. Images of the nasal, temporal, and inferior angles were obtained with AS-OCT in dark and then light conditions. Gonioscopic angle width was graded using the Spaeth classification for each quadrant in low lighting conditions. Angle closure was defined by AS-OCT as contact between the peripheral iris and angle wall anterior to the scleral spur and by gonioscopy as a Spaeth grade of 0 degree (posterior trabecular meshwork not visible). Comparison of the 2 methods in detecting angle closure was done by eye and by individual. Sensitivities and specificities of AS-OCT were calculated using gonioscopy as the reference standard. Complete data were available for 342 eyes of 200 patients. Of the patients, 70.9% had a clinical diagnosis of treated or untreated primary angle closure. Angle closure in > or =1 quadrants was detected by AS-OCT in 142 (71%) patients (228 [66.7%] eyes) and by gonioscopy in 99 (49.5%) patients (152 [44.4%] eyes). The inferior angle was closed more frequently than the nasal or temporal quadrants using both AS-OCT and gonioscopy. When performed under dark conditions, AS-OCT identified 98% of those subjects found to have angle closure on gonioscopy (95% confidence interval [CI], 92.2-99.6) and led to the characterization of 44.6% of those found to have open angles on gonioscopy to have angle closure as well. With gonioscopy as the reference standard

  3. MTHFR gene C677T and A1298C polymorphisms and homocysteine levels in primary open angle and primary closed angle glaucoma

    PubMed Central

    Micheal, Shazia; Qamar, Raheel; Akhtar, Farah; Khan, Muhammad Imran; Khan, Wajid Ali

    2009-01-01

    Purpose To investigate the methylenetetrahydrofolate reductase (MTHFR) C677T and A1298C genotypes and plasma concentrations of total homocysteine (tHcy) in Pakistani patients with primary open angle glaucoma (POAG) and primary closed angle glaucoma (PCAG). Methods This was a prospective case-control study. A total of 295 patients (173 POAG, 122 PCAG) and 143 age- and sex-matched controls were subdivided into two ethnic groups, Punjabis (Punjab province, central Pakistan) and Pathans (North-West Frontier Province, northern Pakistan). Genotypes of the MTHFR C677T and A1298C polymorphisms were detected by polymerase chain reaction–restriction fragment length polymorphism (PCR-RFLP). An enzyme-linked immunosorbent assay was used to determine the total serum homocysteine (tHcy) levels. Associations were determined by logistic regression analysis. Results Frequency distributions of genotypes and combined genotypes as well as homocysteine levels were obtained. The overall distribution of the C677T genotype was found to be significantly associated with PCAG (CC 69%, CT 21%, TT 10%; p=0.001, χ2=12.6), but not with POAG (CC 71%, CT 28%, TT 1%; p=0.98, χ2=0.02) as compared to the controls (CC 71%, CT 29%, TT 1%). The Pathan cohorts revealed no association with the disease; however, the Punjabis demonstrated a significant association with PCAG (CC 75%, CT 11%, TT 13%; p<0.001, χ2=17.2). PCAG in the Punjabi subjects was also significantly associated with the A1298C polymorphism (AA 43%, AC 54%, CC 3%; p<0.001, χ2=33.9) as compared to the controls. Combined genotype data showed no association with POAG; however, a significant association with all combined genotypes was observed in the overall PCAG subjects (p<0.05, χ2=20.1). This difference was particularly apparent in the TTAA and TTAC combinations that were completely absent in the control groups (p<0.05. χ2=49.6). Mean serum tHcy levels were found to be significantly increased in the POAG (15.2±1.28 µmol/l, p<0

  4. Precision determination of electron scattering angle by differential nuclear recoil energy method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liyanage, N.; Saenboonruang, K.

    2015-12-01

    The accurate determination of the scattered electron angle is crucial to electron scattering experiments, both with open-geometry large-acceptance spectrometers and ones with dipole-type magnetic spectrometers for electron detection. In particular, for small central-angle experiments using dipole-type magnetic spectrometers, in which surveys are used to measure the spectrometer angle with respect to the primary electron beam, the importance of the scattering angle determination is emphasized. However, given the complexities of large experiments and spectrometers, the accuracy of such surveys is limited and insufficient to meet demands of some experiments. In this article, we present a new technique for determination of themore » electron scattering angle based on an accurate measurement of the primary beam energy and the principle of differential nuclear recoil. This technique was used to determine the scattering angle for several experiments carried out at the Experimental Hall A, Jefferson Lab. Results have shown that the new technique greatly improved the accuracy of the angle determination compared to surveys.« less

  5. Precision Determination of Electron Scattering Angle by Differential Nuclear Recoil Energy Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liyanage, Nilanga; Saenboonruang, Kiadtisak

    2015-09-01

    The accurate determination of the scattered electron angle is crucial to electron scattering experiments, both with open-geometry large-acceptance spectrometers and ones with dipole-type magnetic spectrometers for electron detection. In particular, for small central-angle experiments using dipole-type magnetic spectrometers, in which surveys are used to measure the spectrometer angle with respect to the primary electron beam, the importance of the scattering angle determination is emphasized. However, given the complexities of large experiments and spectrometers, the accuracy of such surveys is limited and insufficient to meet demands of some experiments. In this article, we present a new technique for determination of themore » electron scattering angle based on an accurate measurement of the primary beam energy and the principle of differential nuclear recoil. This technique was used to determine the scattering angle for several experiments carried out at the Experimental Hall A, Jefferson Lab. Results have shown that the new technique greatly improved the accuracy of the angle determination compared to surveys.« less

  6. Early nucleation events in the polymerization of actin, probed by time-resolved small-angle x-ray scattering

    PubMed Central

    Oda, Toshiro; Aihara, Tomoki; Wakabayashi, Katsuzo

    2016-01-01

    Nucleators generating new F-actin filaments play important roles in cell activities. Detailed information concerning the events involved in nucleation of actin alone in vitro is fundamental to understanding these processes, but such information has been hard to come by. We addressed the early process of salt-induced polymerization of actin using the time-resolved synchrotron small-angle X-ray scattering (SAXS). Actin molecules in low salt solution maintain a monomeric state by an electrostatic repulsive force between molecules. On mixing with salts, the repulsive force was rapidly screened, causing an immediate formation of many of non-polymerizable dimers. SAXS kinetic analysis revealed that tetramerization gives the highest energetic barrier to further polymerization, and the major nucleation is the formation of helical tetramers. Filaments start to grow rapidly with the formation of pentamers. These findings suggest an acceleration mechanism of actin assembly by a variety of nucleators in cells. PMID:27775032

  7. Wildlife openings

    Treesearch

    William M. Healy

    1989-01-01

    Openings provide important feeding areas for forest wildlife because herbaceous vegetation grows much more abundantly in the open than beneath a forest canopy. Herbage (grasses and forbs) is generally more nutritious and digestible than woody plant growth. Herbage is important in the diet of deer, especially in late winter and early spring. Voles and rabbits use...

  8. The effect of internal fixation lamp on anterior chamber angle width measured by anterior segment optical coherence tomography.

    PubMed

    Nakamine, Sakari; Sakai, Hiroshi; Arakaki, Yoshikuni; Yonahara, Michiko; Kaiya, Tadayoshi

    2018-01-01

    To study the effect of the internal fixation lamp on anterior chamber width measured by anterior segment optical coherence tomography. In a prospective cross sectional observational study, consecutive 22 right eyes of 22 patients (4 men and 18 women) with suspected primary angle closure underwent swept source domain anterior segment optical coherence tomography (AS-OCT), (CASIA SS-1000, Tomey, Nagoya, Japan). Anterior chamber parameters of angle opening distance (AOD), trabecular-iris angle (TIA), angle recess area (ARA) at 500 or 750 µm from scleral spur and pupil diameter were measured by AS-OCT in a three-dimensional mode in 4 quadrants (superior, inferior, temporal and nasal) in dark room setting both with and without internal fixation lamp. Anterior segment parameters of AOD 500 in superior, inferior and temporal quadrants, AOD 750 at superior and nasal, TIA 500 at superior, and inferior and TIA 750 at superior and nasal, and ARA 500 or 750 at superior and inferior with internal fixation lamp were greater and the pupil diameter was significantly (all P < 0.05, paired t test) smaller than when measured without fixation lamp. Internal fixation lamp of the anterior segment OCT makes the pupil constrict and angle wider. When using AS-OCT with usual setting with internal fixation lamp on with eyes in which the anterior chamber angle is narrow but open, it is recommended that the internal fixation lamp be turned off to ensure a clear indication as to whether the angle is open or closed in the dark.

  9. Prevalence of primary open-angle glaucoma in an urban south Indian population and comparison with a rural population. The Chennai Glaucoma Study.

    PubMed

    Vijaya, Lingam; George, Ronnie; Baskaran, M; Arvind, Hemamalini; Raju, Prema; Ramesh, S Ve; Kumaramanickavel, Govindasamy; McCarty, Catherine

    2008-04-01

    To estimate the prevalence and risk factors of primary open-angle glaucoma (POAG) in an urban population and compare the same with that of our published rural population data in southern India. Population-based cross-sectional study. Four thousand eight hundred subjects 40 years or older were selected using a multistage random cluster sampling procedure in Chennai city. Three thousand eight hundred fifty (80.2%) subjects underwent a complete ophthalmic examination, including applanation tonometry, gonioscopy, pachymetry, optic disc photography, and automated perimetry. Glaucoma was diagnosed using the International Society of Geographical and Epidemiological Ophthalmology Classification. The distribution of intraocular pressure (IOP) and vertical cup-to-disc ratio (VCDR) was obtained from the right eye of the 2532 subjects with normal suprathreshold visual fields. Mean IOP was 16.17+/-3.74 mmHg (97.5th and 99.5th percentiles, 24 mmHg and 30 mmHg). The mean VCDR was 0.43+/-0.17 (97.5th and 99.5th percentiles, 0.7 and 0.8). One hundred thirty-five (64 men, 71 women) subjects had POAG (3.51%; 95% confidence interval [CI], 3.04-4.0). Primary open-angle glaucoma subjects (58.4+/-11.3 years) were older (P<0.0001) than the study population (54.8+/-10.6 years). One hundred twenty-seven (94%) subjects were diagnosed to have POAG for the first time. Two subjects (1.5%) were bilaterally blind, and 3 (3.3%) were unilaterally blind due to POAG. The urban population prevalence was more than that of the rural population (1.62%; 95% CI, 1.4%-1.8%; P<0.0001). In both populations, increasing IOP (per millimeter of mercury) and older age were associated with the disease. There was no association with gender, myopia, systemic hypertension, diabetes, or central corneal thickness. The prevalence of POAG in a > or =40-year-old south Indian urban population was 3.51%, higher than that of the rural population. The prevalence increased with age, and >90% were not aware of the disease.

  10. Effect of laser UV radiation on the eye scleral tissue in patients with open-angle glaucoma

    NASA Astrophysics Data System (ADS)

    Razhev, A. M.; Iskakov, I. A.; Churkin, D. S.; Orishich, A. M.; Maslov, N. A.; Tsibul'skaya, E. O.; Lomzov, A. A.; Ermakova, O. V.; Trunov, A. N.; Chernykh, V. V.

    2018-05-01

    We report the results of an experimental study of the effect of short-pulse laser UV radiation on the eye scleral tissue. As samples, we used isolated flaps of the eye scleral tissue from the patients with open-angle glaucoma of the second and third stages. The impact was implemented using the radiation of an excimer XeCl laser with a wavelength of 308 nm and a laser with a wavelength tunable within from 210 to 355 nm. Depending on the problem to be solved, the energy density on the surface of the irradiated tissue varied from a fraction of mJ cm-2 to 15 J cm-2. For the first time we studied the optical properties of the intraocular fluid in the UV and blue spectral range. The study of the ablation process under the action of radiation with a wavelength of 308 nm showed that the rate of material evaporation can vary within 24%–30% at an energy density above 7 J cm-2, depending on the glaucoma stage and the individual features of a patient. The excitation–emission matrices of laser-induced fluorescence (LIF) of the eye scleral tissue were studied experimentally using a laser with a wavelength tuned in the range 210–355 nm. We found the differences in the LIF spectra caused by the excitation wavelength and the openangle glaucoma stage.

  11. Relationship between anthropometric parameters and open angle glaucoma: The Korea National Health and Nutrition Examination Survey.

    PubMed

    Lee, Jae Yeun; Kim, Tae-Woo; Kim, Hyun Tae; Lee, Mi Yeon; Min, Hye Won; Won, Yu Sam; Kwon, Hyun Seok; Park, Ki Ho; Kim, Joon Mo

    2017-01-01

    To evaluate the relationships between open-angle glaucoma (OAG) and various anthropometric measurements. Korea National Health and Nutrition Examination Survey (KNHANES), a population-based cross-sectional study using a complex, stratified, multistage, probability-cluster survey. A total of 5,255 participants including 247 glaucoma patients, aged ≥ 19 years were included from the KNHANES V database. Glaucoma diagnosis was based on International Society of Geographical and Epidemiological Ophthalmology criteria. Various anthropometric data regarding obesity were analyzed including body mass index (BMI), total body fat mass, total body muscle mass (lean body mass, non-bone lean body mass, and appendicular skeletal muscle (ASM) mass), and waist circumference (WC). The differences in OAG prevalence with respect to anthropometric parameter quartiles were examined. In males, the multivariate general linear model adjusted for age, alcohol, smoking, exercise, systemic hypertension, diabetes, and intraocular pressure (IOP) showed the quartiles for the anthropometric parameters BMI, fat mass/weight ratio and fat mass/muscle mass ratio were negatively associated with OAG. However, muscle mass parameter/BMI ratio was significantly positively associated with OAG (P for trend<0.05). In females, height and fat mass/BMI showed a significant relationship with the risk of OAG. (P value<0.05). In the present study, high fat mass was associated with low OAG risk. Body composition seemed to affect the prevalence of OAG, but further evaluation is needed.

  12. Comparative study of the retinal nerve fibre layer thickness performed with optical coherence tomography and GDx scanning laser polarimetry in patients with primary open-angle glaucoma

    PubMed Central

    Wasyluk, Jaromir T.; Jankowska-Lech, Irmina; Terelak-Borys, Barbara; Grabska-Liberek, Iwona

    2012-01-01

    Summary Background We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. Material/Methods Study subjects had advanced primary open-angle glaucoma, previously treated conservatively, diagnosed and confirmed by additional examinations (visual field, ophthalmoscopy of optic nerve, gonioscopy), A total of 10 patients were enrolled (9 women and 1 man), aged 18–70 years of age. Nineteen eyes with advanced glaucomatous neuropathy were examined. 1) Performing a threshold perimetry Octopus, G2 strategy and ophthalmoscopy of optic nerve to confirm the presence of advanced primary open-angle glaucoma; 2) performing a GDx VCC scanning laser polarimetry of retinal nerve fibre layer; 3) measuring the retinal nerve fibre layer thickness with 3 different optical coherence tomographs. Results The parameters of the retinal nerve fibre layer thickness are highly correlated between the GDx and OCT Stratus and 3D OCT-1000 devices in mean retinal nerve fibre layer thickness, retinal nerve fibre layer thickness in the upper sector, and correlation of NFI (GDx) with mean retinal nerve fibre layer thickness in OCT examinations. Absolute values of the retinal nerve fibre layer thickness (measured in μm) differ significantly between GDx and all OCT devices. Conclusions Examination with OCT devices is a sensitive diagnostic method of glaucoma, with good correlation with the results of GDx scanning laser polarimetry of the patients. PMID:22367131

  13. BioXTAS RAW: improvements to a free open-source program for small-angle X-ray scattering data reduction and analysis.

    PubMed

    Hopkins, Jesse Bennett; Gillilan, Richard E; Skou, Soren

    2017-10-01

    BioXTAS RAW is a graphical-user-interface-based free open-source Python program for reduction and analysis of small-angle X-ray solution scattering (SAXS) data. The software is designed for biological SAXS data and enables creation and plotting of one-dimensional scattering profiles from two-dimensional detector images, standard data operations such as averaging and subtraction and analysis of radius of gyration and molecular weight, and advanced analysis such as calculation of inverse Fourier transforms and envelopes. It also allows easy processing of inline size-exclusion chromatography coupled SAXS data and data deconvolution using the evolving factor analysis method. It provides an alternative to closed-source programs such as Primus and ScÅtter for primary data analysis. Because it can calibrate, mask and integrate images it also provides an alternative to synchrotron beamline pipelines that scientists can install on their own computers and use both at home and at the beamline.

  14. Recent Coverage of Early Childhood Education Approaches in Open Access Early Childhood Journals

    ERIC Educational Resources Information Center

    Keskin, Burhanettin

    2016-01-01

    A content analysis of the coverage of the major approaches to early childhood education in the early childhood research journals, published between 2010 and 2014, that are early childhood research oriented and have free online access were investigated. Among 21 journals in early childhood education, two journals were selected for the content…

  15. A method to measure internal contact angle in opaque systems by magnetic resonance imaging.

    PubMed

    Zhu, Weiqin; Tian, Ye; Gao, Xuefeng; Jiang, Lei

    2013-07-23

    Internal contact angle is an important parameter for internal wettability characterization. However, due to the limitation of optical imaging, methods available for contact angle measurement are only suitable for transparent or open systems. For most of the practical situations that require contact angle measurement in opaque or enclosed systems, the traditional methods are not effective. Based upon the requirement, a method suitable for contact angle measurement in nontransparent systems is developed by employing MRI technology. In the Article, the method is demonstrated by measuring internal contact angles in opaque cylindrical tubes. It proves that the method also shows great feasibility in transparent situations and opaque capillary systems. By using the method, contact angle in opaque systems could be measured successfully, which is significant in understanding the wetting behaviors in nontransparent systems and calculating interfacial parameters in enclosed systems.

  16. Relationship between blood pressure and retrobulbar blood flow in dipper and nondipper primary open-angle glaucoma patients.

    PubMed

    Marjanović, Ivan; Marjanović, Marija; Martinez, Antonio; Marković, Vujica; Božić, Marija; Stojanov, Vesna

    2016-11-04

    To evaluate the relationship between retrobulbar hemodynamic parameters in the ophthalmic artery (OA), central retinal artery, and short posterior ciliary artery and 24-hour blood pressure (BP) measurements in dipper and nondipper patients with primary open-angle glaucoma (POAG). A prospective, cross-sectional, and observational study was conducted on consecutive patients, referred or recruited, attending the outpatient service of our ophthalmology department. Ambulatory BP monitoring, Doppler imaging, and ocular pulse amplitude measurements were performed on the same day. Patients with nocturnal BP decrease up to 10% of the diurnal BP were defined as dippers and those with BP decrease less than 10% were defined as nondippers. A total of 114 patients (36 nondippers and 78 dippers) were included in the study. The end-diastolic velocity was significantly lower and the resistivity index (RI) was significantly higher in the dippers than in the nondippers (p<0.0001 and p<0.0001, respectively). The RI in the OA was significantly correlated with daytime and nighttime systolic BP and with the daytime mean arterial pressure in the dippers. The RI in the OA significantly correlates with BP in patients with POAG with nocturnal BP dips. Additionally, retrobulbar blood flow parameters are reduced in dippers as compared with nondippers with POAG.

  17. A review of preserved and preservative-free prostaglandin analogues for the treatment of open-angle glaucoma and ocular hypertension.

    PubMed

    Hommer, A

    2010-06-01

    Glaucoma affects an increasing number of people worldwide and is the second leading cause of blindness. The aim of antiglaucoma therapy is to maintain a patient's visual function and quality of life. Prostaglandin analogues are first-line topical antiglaucoma therapy. They are effective at lowering intraocular pressure (IOP) and are generally well tolerated, with fewer systemic adverse events compared with the other classes. However, the use of prostaglandin analogues can be associated with ocular adverse effects, such as stinging/burning sensation, dry eyes, iris and periocular hyperpigmentation, and eye lash growth, which can affect patient compliance. Preservatives used in antiglaucoma preparations can have dose-dependent toxic effects, which contribute to adverse effects. The development of preservative-free preparations may reduce such adverse effects and therefore improve patient compliance. Tafluprost is a prostaglandin analogue in a preservative-free formulation that was recently approved for the reduction of elevated IOP in open-angle glaucoma and ocular hypertension. Copyright 2010 Prous Science, S.A.U. or its licensors. All rights reserved.

  18. Opening Health Data: What Do Researchers Want? Early Experiences With New York's Open Health Data Platform.

    PubMed

    Martin, Erika G; Helbig, Natalie; Birkhead, Guthrie S

    2015-01-01

    Governments are rapidly developing open data platforms to improve transparency and make information more accessible. New York is a leader, with currently the only state platform devoted to health. Although these platforms could build public health departments' capabilities to serve more researchers, agencies have little guidance on releasing meaningful and usable data. Structured focus groups with researchers and practitioners collected stakeholder feedback on potential uses of open health data and New York's open data strategy. Researchers and practitioners attended a 1-day November 2013 workshop on New York State's open health data resources. After learning about the state's open data platform and vision for open health data, participants were organized into 7 focus groups to discuss the essential elements of open data sets, practical challenges to obtaining and using health data, and potential uses of open data. Participants included 33 quantitative health researchers from State University of New York campuses and private partners and 10 practitioners from the New York State Department of Health. There was low awareness of open data, with 67% of researchers reporting never using open data portals prior to the workshop. Participants were interested in data sets that were geocoded, longitudinal, or aggregated to small area granularity and capabilities to link multiple data sets. Multiple environmental conditions and barriers hinder their capacity to use health data for research. Although open data platforms cannot address all barriers, they provide multiple opportunities for public health research and practice, and participants were overall positive about the state's efforts to release open data. Open data are not ideal for some researchers because they do not contain individually identifiable data, indicating a need for tiered data release strategies. However, they do provide important new opportunities to facilitate research and foster collaborations among

  19. Complications and Reoperations in Mandibular Angle Fractures.

    PubMed

    Chen, Collin L; Zenga, Joseph; Patel, Ruchin; Branham, Gregory

    2018-05-01

    Mandible angle fractures can be repaired in a variety of ways, with no consensus on the outcomes of complications and reoperation rates. To analyze patient, injury, and surgical factors, including approach to the angle and plating technique, associated with postoperative complications, as well as the rate of reoperation with regard to mandible angle fractures. Retrospective cohort study analyzing the surgical outcomes of patients with mandible angle fractures between January 1, 2000, and December 31, 2015, who underwent open reduction and internal fixation. Patients were eligible if they were aged 18 years or older, had 3 or less mandible fractures with 1 involving the mandibular angle, and had adequate follow-up data. Patients with comminuted angle fractures, bilateral angle fractures, and multiple surgical approaches were excluded. A total of 135 patients were included in the study. All procedures were conducted at a single, large academic hospital located in an urban setting. Major complications and reoperation rates. Major complications included in this study were nonunion, malunion, severe malocclusion, severe infection, and exposed hardware. Of 135 patients 113 (83.7%) were men; median age was 29 years (range, 18-82 years). Eighty-seven patients (64.4%) underwent the transcervical approach and 48 patients (35.6%) received the transoral approach. Fifteen (17.2%) patients in the transcervical group and 9 (18.8%) patients in the transoral group experienced major complications (difference, 1%; 95% CI, -8% to 10%). Thirteen (14.9%) patients in the transcervical group and 8 (16.7%) patients in the transoral group underwent reoperations (difference, 2%; 95% CI, -13% to 17%). Active smoking had a significant effect on the rate of major complications (odds ratio, 4.04; 95% CI, 1.07 to 15.34; P = .04). During repair of noncomminuted mandibular angle fractures, both of the commonly used approaches-transcervical and transoral-can be used during treatment with equal

  20. Correlation of pattern reversal visual evoked potential parameters with the pattern standard deviation in primary open angle glaucoma.

    PubMed

    Kothari, Ruchi; Bokariya, Pradeep; Singh, Ramji; Singh, Smita; Narang, Purvasha

    2014-01-01

    To evaluate whether glaucomatous visual field defect particularly the pattern standard deviation (PSD) of Humphrey visual field could be associated with visual evoked potential (VEP) parameters of patients having primary open angle glaucoma (POAG). Visual field by Humphrey perimetry and simultaneous recordings of pattern reversal visual evoked potential (PRVEP) were assessed in 100 patients with POAG. The stimulus configuration for VEP recordings consisted of the transient pattern reversal method in which a black and white checker board pattern was generated (full field) and displayed on VEP monitor (colour 14″) by an electronic pattern regenerator inbuilt in an evoked potential recorder (RMS EMG EP MARK II). The results of our study indicate that there is a highly significant (P<0.001) negative correlation of P100 amplitude and a statistically significant (P<0.05) positive correlation of N70 latency, P100 latency and N155 latency with the PSD of Humphrey visual field in the subjects of POAG in various age groups as evaluated by Student's t-test. Prolongation of VEP latencies were mirrored by a corresponding increase of PSD values. Conversely, as PSD increases the magnitude of VEP excursions were found to be diminished.

  1. Charge-density-wave partial gap opening in quasi-2D KMo 6O 17 purple bronze studied by angle resolved photoemission spectroscopy

    NASA Astrophysics Data System (ADS)

    Valbuena, M. A.; Avila, J.; Pantin, V.; Drouard, S.; Guyot, H.; Asensio, M. C.

    2006-05-01

    Low dimensional (LD) metallic oxides have been a subject of continuous interest in the last two decades, mainly due to the electronic instabilities that they present at low temperatures. In particular, charge density waves (CDW) instabilities associated with a strong electron-phonon interaction have been found in Molybdenum metallic oxides such as KMo 6O 17 purple bronze. We report an angle resolved photoemission (ARPES) study from room temperature (RT) to T ˜40 K well below the Peierls transition temperature for this material, with CDW transition temperature TCDW ˜120 K. We have focused on photoemission spectra along ΓM high symmetry direction as well as photoemission measurements were taken as a function of temperature at one representative kF point in the Brillouin zone in order to look for the characteristic gap opening after the phase transition. We found out a pseudogap opening and a decrease in the density of states near the Fermi energy, EF, consistent with the partial removal of the nested portions of the Fermi surface (FS) at temperature below the CDW transition. In order to elucidate possible Fermi liquid (FL) or non-Fermi liquid (NFL) behaviour we have compared the ARPES data with that one reported on quasi-1D K 0.3MoO 3 blue bronze.

  2. Equilibrium contact angle or the most-stable contact angle?

    PubMed

    Montes Ruiz-Cabello, F J; Rodríguez-Valverde, M A; Cabrerizo-Vílchez, M A

    2014-04-01

    It is well-established that the equilibrium contact angle in a thermodynamic framework is an "unattainable" contact angle. Instead, the most-stable contact angle obtained from mechanical stimuli of the system is indeed experimentally accessible. Monitoring the susceptibility of a sessile drop to a mechanical stimulus enables to identify the most stable drop configuration within the practical range of contact angle hysteresis. Two different stimuli may be used with sessile drops: mechanical vibration and tilting. The most stable drop against vibration should reveal the changeless contact angle but against the gravity force, it should reveal the highest resistance to slide down. After the corresponding mechanical stimulus, once the excited drop configuration is examined, the focus will be on the contact angle of the initial drop configuration. This methodology needs to map significantly the static drop configurations with different stable contact angles. The most-stable contact angle, together with the advancing and receding contact angles, completes the description of physically realizable configurations of a solid-liquid system. Since the most-stable contact angle is energetically significant, it may be used in the Wenzel, Cassie or Cassie-Baxter equations accordingly or for the surface energy evaluation. © 2013 Elsevier B.V. All rights reserved.

  3. Can orbital angle morphology distinguish dogs from wolves?

    PubMed

    Janssens, Luc; Spanoghe, Inge; Miller, Rebecca; Van Dongen, Stefan

    For more than a century, the orbital angle has been studied by many authors to distinguish dog skulls from their progenitor, the wolf. In early studies, the angle was reported to be different between dogs (49°-55°) and wolves (39°-46°). This clear difference was, however, questioned in a more recent Scandinavian study that shows some overlap. It is clear that in all studies several methodological issues were unexplored or unclear and that group sizes and the variety of breeds and wolf subspecies were small. Archaeological dog skulls had also not been studied. Our goal was to test larger and more varied groups and add archaeological samples as they are an evolutionary stage between wolves and modern dogs. We also tested the influence of measuring methods, intra- and inter-reliability, angle symmetry, the influence of variations in skull position and the possibility of measuring and comparing this angle on 3D CT scan images. Our results indicate that there is about 50 % overlap between the angle range in wolves and modern dogs. However, skulls with a very narrow orbital angle were only found in wolves and those with a very wide angle only in dogs. Archaeological dogs have a mean angle very close to the one of the wolves. Symmetry is highest in wolves and lowest in archaeological dogs. The measuring method is very reliable, for both inter- and intra-reliability (0.99-0.97), and most skull position changes have no statistical influence on the angle measured. Three-dimensional CT scan images can be used to measure OA, but the angles differ from direct measuring and cannot be used for comparison. Evolutionary changes in dog skulls responsible for the wider OA compared to wolf skulls are mainly the lateralisation of the zygomatic process of the frontal bone. Our conclusion is that the orbital angle can be used as an additional morphological measuring method to discern wolves from recent and archaeological dogs. Angles above 60° are certainly from recent dogs. Angles

  4. [Macular choroidal blood flow in concurrent age-related macular degeneration and primary open-angle glaucoma].

    PubMed

    Panova, I E; Ermak, E M; Shaimova, T A; Shaimova, V A

    2016-01-01

    Ocular circulation disorders are an important factor in the development of primary open-angle glaucoma (POAG) and age-related macular degeneration (AMD). To date, however, there have been no studies on choroidal blood flow peculiarities in case of concurrent AMD and POAG. to determine distinctive features of choroidal blood flow characteristic of concurrent AMD and POAG and to assess their role in disease pathogenesis. Macular choroidal blood flow, including blood supply, was assessed in 54 patients (102 eyes) by means of Doppler ultrasound. Three groups were formed: group 1 - 38 eyes with both AMD and POAG; group 2 - 41 eyes with AMD and no signs of optic nerve pathology; and group 3 - 23 eyes with POAG and no signs of AMD. Groups 1 and 2 were subdivided into two subgroups each: А - atrophic AMD and B - macular drusen. The mean patient age was 78.7±8.4 years. The following parameters of choroidal blood flow were of interest: peak systolic velocity (Vps), end diastolic velocity (Ved), time-averaged maximum velocity (Vtamax), and resistance index (RI). Groups 1, 3, and 2A had an evident choroidal hypoperfusion in the macular area (decreased Vtamax) with uncompensated perfusion deficit, despite autoregulation efforts (decreased Vps, Ved, decreased or normal RI). Group 2B demonstrated a significantly higher rate of choroidal hyperperfusion (increased Vps, Ved, Vtamax, and RI). Concurrent AMD and POAG are notable for choroidal hypoperfusion in the macular area that leads to inadequate trophism of the neurosensory retina and can aggravate the course of AMD contributing to progression of its atrophic form.

  5. Relationship between progression of visual field defect and intraocular pressure in primary open-angle glaucoma.

    PubMed

    Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Shiraga, Fumio

    2015-01-01

    To analyze the relationship between intraocular pressure (IOP) and the progression of visual field defects in Japanese primary open-angle glaucoma (POAG) and normal-tension glaucoma (NTG) patients. The subjects of the study were patients undergoing treatment for POAG or NTG who had performed visual field tests at least ten times with a Humphrey field analyzer (Swedish interactive thresholding algorithm standard, C30-2 program). The progression of visual field defects was defined by a significantly negative value of the mean deviation slope at the final visual field test during the follow-up period. The relationships between the progression of visual field defects and IOP, as well as other clinical factors, were retrospectively analyzed. A total of 156 eyes of 156 patients were included in the analysis. Significant progression of visual field defects was observed in 70 eyes of 70 patients (44.9%), while no significant progression was evident in 86 eyes of 86 patients (55.1%). The eyes with visual field defect progression had significantly lower baseline IOP (P<0.05), as well as significantly lower IOP reduction rate (P<0.01). The standard deviation of IOP values during follow-up was significantly greater in the eyes with visual field defect progression than in eyes without (P<0.05). Reducing IOP is thought to be useful for Japanese POAG or NTG patients to suppress the progression of visual field defects. In NTG, IOP management should take into account not only achieving the target IOP, but also minimizing the fluctuation of IOP during follow-up period.

  6. Rates of glaucoma medication utilization among persons with primary open-angle glaucoma, 1992 to 2002.

    PubMed

    Stein, Joshua D; Ayyagari, Padmaja; Sloan, Frank A; Lee, Paul P

    2008-08-01

    To determine the percentage of Medicare beneficiaries with primary open-angle glaucoma (POAG) treated medically or surgically, utilization rates for each major class of glaucoma medication, and factors influencing treatment. Longitudinal observational study using data from the Medicare Current Beneficiary Survey (MCBS). Persons age 65 and older with POAG, 1992 to 2002 (N = 6446). By using MCBS data merged with Medicare claims, rates of medical and surgical treatment for participants with POAG were determined. Logistic analysis was used to assess factors associated with use of care. Receipt/nonreceipt of medical or surgical therapy in a year and rates of drug utilization by class and of surgery by type among persons who did not receive medical therapy in a year. On average from 1992 to 2002, 27.4% of persons diagnosed with POAG received no medical or surgical treatment. Rates of nonuse increased by 3% annually (odds ratio [OR], 1.03; 95% confidence interval [CI], 1.02-1.05). Beneficiaries with Medicaid were 43% more likely not to receive care for POAG in a year (OR, 1.43; 95% CI, 1.20-1.70). Hispanic, Asian, and beneficiaries of other race/ethnicity were less likely to receive treatment than were whites. Use of beta-blockers and miotics decreased, but utilization rates increased substantially for alpha-agonists, combination beta-blocker-carbonic anhydrase inhibitors, and especially prostaglandin analogs. Despite availability of more efficacious glaucoma medication classes with few side effects and findings of clinical trials underscoring the importance of intraocular pressure reduction in POAG patients, many patients with POAG continue to go untreated.

  7. Hierarchical cluster analysis of progression patterns in open-angle glaucoma patients with medical treatment.

    PubMed

    Bae, Hyoung Won; Rho, Seungsoo; Lee, Hye Sun; Lee, Naeun; Hong, Samin; Seong, Gong Je; Sung, Kyung Rim; Kim, Chan Yun

    2014-04-29

    To classify medically treated open-angle glaucoma (OAG) by the pattern of progression using hierarchical cluster analysis, and to determine OAG progression characteristics by comparing clusters. Ninety-five eyes of 95 OAG patients who received medical treatment, and who had undergone visual field (VF) testing at least once per year for 5 or more years. OAG was classified into subgroups using hierarchical cluster analysis based on the following five variables: baseline mean deviation (MD), baseline visual field index (VFI), MD slope, VFI slope, and Glaucoma Progression Analysis (GPA) printout. After that, other parameters were compared between clusters. Two clusters were made after a hierarchical cluster analysis. Cluster 1 showed -4.06 ± 2.43 dB baseline MD, 92.58% ± 6.27% baseline VFI, -0.28 ± 0.38 dB per year MD slope, -0.52% ± 0.81% per year VFI slope, and all "no progression" cases in GPA printout, whereas cluster 2 showed -8.68 ± 3.81 baseline MD, 77.54 ± 12.98 baseline VFI, -0.72 ± 0.55 MD slope, -2.22 ± 1.89 VFI slope, and seven "possible" and four "likely" progression cases in GPA printout. There were no significant differences in age, sex, mean IOP, central corneal thickness, and axial length between clusters. However, cluster 2 included more high-tension glaucoma patients and used a greater number of antiglaucoma eye drops significantly compared with cluster 1. Hierarchical cluster analysis of progression patterns divided OAG into slow and fast progression groups, evidenced by assessing the parameters of glaucomatous progression in VF testing. In the fast progression group, the prevalence of high-tension glaucoma was greater and the number of antiglaucoma medications administered was increased versus the slow progression group. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  8. 360-degree suture trabeculotomy ab interno to treat open-angle glaucoma: 2-year outcomes

    PubMed Central

    Sato, Tomoki; Kawaji, Takahiro; Hirata, Akira; Mizoguchi, Takanori

    2018-01-01

    Purpose The purpose of this study was to evaluate the efficacy of 360-degree suture trabeculotomy (360S-LOT) ab interno for treating open-angle glaucoma (OAG). Risk factors of surgical failure were examined. Patients and methods 360S-LOT ab interno alone was performed for patients with uncontrolled OAG, and combined 360S-LOT ab interno/phacoemulsification was performed for patients with controlled OAG with a visually significant cataract between March 2014 and September 2015 at a single center. The patients were prospectively followed for 2 years. The main outcome measures included 2-year intraocular pressure (IOP), number of anti-glaucoma medications used, postoperative complications, and predictive factors of surgical failure. Kaplan–Meier analysis was performed, with surgical success (with or without medication use) defined as postoperative IOP ≤15 mmHg and IOP reduction ≥20% (criterion A) or IOP ≤12 mmHg and IOP reduction ≥30% (criterion B). Predictive factors were evaluated using Cox proportional hazard ratios. Results A total of 64 eyes of 64 patients were included, and 50 (78%) eyes of 64 eyes underwent a phacoemulsification combination procedure. Surgery significantly reduced IOP from 18.4 ± 2.9 mmHg before surgery to 13.4 ± 3.0 mmHg after surgery (P < 0.001). Patients used an average of 1.8 ± 1.5 medications before surgery and 1.3 ± 1.5 medications after surgery (P = 0.101). No serious postoperative complications were observed. The probability of surgical success was 49.2% and 16.0% using criteria A and B, respectively. No risk factors of surgical failure were identified. Conclusion The 360S-LOT ab interno procedure is a favorable option for treating eyes with mild or moderate OAG. PMID:29844656

  9. The ISW effect and the lack of large-angle CMB temperature correlations

    NASA Astrophysics Data System (ADS)

    Copi, Craig J.; O'Dwyer, Márcio; Starkman, Glenn D.

    2016-12-01

    It is by now well established that the magnitude of the two-point angular-correlation function of the cosmic microwave background temperature anisotropies is anomalously low for angular separations greater than about 60°. Physics explanations of this anomaly typically focus on the properties of the Universe at the surface of last scattering, relying on the fact that large-angle temperature fluctuations are dominated by the Sachs-Wolfe effect (SW). However, these fluctuations also receive important contributions from the integrated Sachs-Wolfe effect (ISW) at both early (eISW) and late (ℓISW) times. Here, we study the correlations in those large-angle temperature fluctuations and their relative contributions to S1/2- the standard measure of the correlations on large angular scales. We find that in the best-fitting lambda cold dark matter (ΛCDM) cosmology, while the autocorrelation of the early contributions (SW plus eISW) dominates S1/2, there are also significant contributions originating from cross-terms between the early and late contributions. In particular, realizations of ΛCDM with low S1/2 are typically produced from a combination of somewhat low pure-early correlations and accidental cancellations among early-late correlations. We also find that if the pure ℓISW autocorrelations were the only contribution to S1/2 in ΛCDM, then the p-value of the observed cut-sky S1/2 would be unremarkable. This suggests that the physical mechanisms operating only at or near the last scattering surface could explain the observed lack of large-angle correlations, though this is not the typical resolution within ΛCDM.

  10. Comparison of the diagnostic ability of Moorfield’s regression analysis and glaucoma probability score using Heidelberg retinal tomograph III in eyes with primary open angle glaucoma

    PubMed Central

    Jindal, Shveta; Dada, Tanuj; Sreenivas, V; Gupta, Viney; Sihota, Ramanjit; Panda, Anita

    2010-01-01

    Purpose: To compare the diagnostic performance of the Heidelberg retinal tomograph (HRT) glaucoma probability score (GPS) with that of Moorfield’s regression analysis (MRA). Materials and Methods: The study included 50 eyes of normal subjects and 50 eyes of subjects with early-to-moderate primary open angle glaucoma. Images were obtained by using HRT version 3.0. Results: The agreement coefficient (weighted k) for the overall MRA and GPS classification was 0.216 (95% CI: 0.119 – 0.315). The sensitivity and specificity were evaluated using the most specific (borderline results included as test negatives) and least specific criteria (borderline results included as test positives). The MRA sensitivity and specificity were 30.61 and 98% (most specific) and 57.14 and 98% (least specific). The GPS sensitivity and specificity were 81.63 and 73.47% (most specific) and 95.92 and 34.69% (least specific). The MRA gave a higher positive likelihood ratio (28.57 vs. 3.08) and the GPS gave a higher negative likelihood ratio (0.25 vs. 0.44).The sensitivity increased with increasing disc size for both MRA and GPS. Conclusions: There was a poor agreement between the overall MRA and GPS classifications. GPS tended to have higher sensitivities, lower specificities, and lower likelihood ratios than the MRA. The disc size should be taken into consideration when interpreting the results of HRT, as both the GPS and MRA showed decreased sensitivity for smaller discs and the GPS showed decreased specificity for larger discs. PMID:20952832

  11. Relationship between anthropometric parameters and open angle glaucoma: The Korea National Health and Nutrition Examination Survey

    PubMed Central

    Lee, Jae Yeun; Kim, Tae-Woo; Kim, Hyun Tae; Lee, Mi Yeon; Min, Hye Won; Won, Yu Sam; Kwon, Hyun Seok; Park, Ki Ho; Kim, Joon Mo

    2017-01-01

    Aims To evaluate the relationships between open-angle glaucoma (OAG) and various anthropometric measurements. Design Korea National Health and Nutrition Examination Survey (KNHANES), a population-based cross-sectional study using a complex, stratified, multistage, probability-cluster survey. Methods A total of 5,255 participants including 247 glaucoma patients, aged ≥ 19 years were included from the KNHANES V database. Glaucoma diagnosis was based on International Society of Geographical and Epidemiological Ophthalmology criteria. Various anthropometric data regarding obesity were analyzed including body mass index (BMI), total body fat mass, total body muscle mass (lean body mass, non-bone lean body mass, and appendicular skeletal muscle (ASM) mass), and waist circumference (WC). The differences in OAG prevalence with respect to anthropometric parameter quartiles were examined. Results In males, the multivariate general linear model adjusted for age, alcohol, smoking, exercise, systemic hypertension, diabetes, and intraocular pressure (IOP) showed the quartiles for the anthropometric parameters BMI, fat mass/weight ratio and fat mass/muscle mass ratio were negatively associated with OAG. However, muscle mass parameter/BMI ratio was significantly positively associated with OAG (P for trend<0.05). In females, height and fat mass/BMI showed a significant relationship with the risk of OAG. (P value<0.05) Conclusions In the present study, high fat mass was associated with low OAG risk. Body composition seemed to affect the prevalence of OAG, but further evaluation is needed. PMID:28481907

  12. Current concepts on primary open-angle glaucoma genetics: a contribution to disease pathophysiology and future treatment

    PubMed Central

    Gemenetzi, M; Yang, Y; Lotery, A J

    2012-01-01

    Glaucoma is a common, complex, heterogenous disease and it constitutes the major cause of irreversible blindness worldwide. Primary open-angle glaucoma (POAG) is the most common type of glaucoma in all populations. Most of the molecular mechanisms leading to POAG development are still unknown. Gene mutations in various populations have been identified by genetic studies and a genetic basis for glaucoma pathogenesis has been established. Linkage analysis and association studies are genetic approaches in the investigation of the genetic basis of POAG. Genome-wide association studies (GWAS) are more powerful compared with linkage analysis in discovering genes of small effect that might contribute to the development of the disease. POAG links to at least 20 genetic loci, but only 2 genes identified in these loci, myocilin and optineurin, are considered as well-established glaucoma-causing genes, whereas the role of other loci, genes, and variants implicated in the development of POAG remains controversial. Gene mutations associated with POAG result in retinal ganglion cell death, which is the common outcome of pathogenetic mechanisms in glaucoma. In future, if the sensitivity and specificity of genotyping increases, it may be possible to screen individuals routinely for disease susceptibility. This review is an update on the latest progress of genetic studies associated with POAG. It emphasizes the correlation of recent achievements in genetics with glaucoma pathophysiology, glaucoma treatment perspectives, and the possibility of future prevention of irreversible visual loss caused by the disease. PMID:22173078

  13. Evaluating intraocular pressure-lowering solutions for the treatment of open-angle glaucoma: comparison between bimatoprost 0.03% and bimatoprost 0.01% - an observational switch study.

    PubMed

    Deshpande, Sarita S; Sonty, Sriram; Ahmad, Afzal

    2017-01-01

    The purpose of this study is to evaluate the intraocular pressure (IOP)-lowering efficacy of bimatoprost 0.01% solution in patients with primary open-angle glaucoma (POAG), who were switched from bimatoprost 0.03% solution, compared to patients with POAG who continued on bimatoprost 0.03% solution. A retrospective review evaluated 35 patients (35 right eyes [OD], 34 left eyes [OS]) who remained on bimatoprost 0.03% and 30 patients (27 OD, 30 OS) who were switched to bimatoprost 0.01% during the period January 8, 2010 to December 26, 2012. Mean IOP was measured 6 and 3 months before the switch, at switch, and 3, 6, and 12 months after the switch. Hyperemia scores were recorded before and after the switch and were compared to a picture scale. Mean IOP in the group that switched was 16.96±5.03 mmHg in OD and 17.67±5.33 mmHg in OS at baseline. Mean IOP postswitch to bimatoprost 0.01% solution was 17.60±4.34 mmHg in OD and 17.00±3.37 mmHg in OS. IOP was not significantly reduced in either OD or OS postswitch to bimatoprost 0.01% ( P 1 =0.5 OD, P 2 =0.2 OS). The hyperemia scores improved remarkably when bimatoprost 0.03% solution was switched to bimatoprost 0.01% solution ( P <0.001). To our knowledge, this is the first switch study evaluating the hypotensive efficacy and tolerability of bimatoprost in a group of patients with open-angle glaucoma. In this study comparing bimatoprost 0.03% and 0.01% solution, we found improved tolerability postswitch to 0.01% from 0.03% bimatoprost, similar efficacy between the two concentrations before and after switch in the same patient population, and similar IOPs comparable to nonswitch bimatoprost 0.03% solution.

  14. Anterior Chamber Angle Shape Analysis and Classification of Glaucoma in SS-OCT Images.

    PubMed

    Ni Ni, Soe; Tian, J; Marziliano, Pina; Wong, Hong-Tym

    2014-01-01

    Optical coherence tomography is a high resolution, rapid, and noninvasive diagnostic tool for angle closure glaucoma. In this paper, we present a new strategy for the classification of the angle closure glaucoma using morphological shape analysis of the iridocorneal angle. The angle structure configuration is quantified by the following six features: (1) mean of the continuous measurement of the angle opening distance; (2) area of the trapezoidal profile of the iridocorneal angle centered at Schwalbe's line; (3) mean of the iris curvature from the extracted iris image; (4) complex shape descriptor, fractal dimension, to quantify the complexity, or changes of iridocorneal angle; (5) ellipticity moment shape descriptor; and (6) triangularity moment shape descriptor. Then, the fuzzy k nearest neighbor (fkNN) classifier is utilized for classification of angle closure glaucoma. Two hundred and sixty-four swept source optical coherence tomography (SS-OCT) images from 148 patients were analyzed in this study. From the experimental results, the fkNN reveals the best classification accuracy (99.11 ± 0.76%) and AUC (0.98 ± 0.012) with the combination of fractal dimension and biometric parameters. It showed that the proposed approach has promising potential to become a computer aided diagnostic tool for angle closure glaucoma (ACG) disease.

  15. Reflectance Spectra of Peacock Feathers and the Turning Angles of Melanin Rods in Barbules.

    PubMed

    Okazaki, Toshio

    2018-02-01

    I analyzed the association between the reflectance spectra and melanin rod arrangement in barbules of the eyespot of peacock feathers. The reflectance spectra from the yellow-green feather of the eyespot indicated double peaks of 430 and 540 nm. The maximum reflectance spectrum of the blue feather was 480 nm, and that of the dark blue feather was 420 nm. The reflectance spectra from brown feathers indicated double peaks of 490 and 610 nm. Transmission electron microscopic analysis confirmed that melanin rods were arranged fanwise in the outer layer toward the barbule tips. In addition, using polarized light microscope, I attempted to determine whether the turning angles of melanin rods in the barbules reflected different colors. The turning angle of the polarizing axis of the barbules was supported by that of the melanin rods, observed using transmission electron microscopic images. To compare the turning angle of melanin rods in the respective barbules, I calculated the opening width of the fanwise melanin rods by dividing the width of the barbules by the turning angle of the polarizing axis of barbules and obtained a positive correlation between the reflectance spectra and opening width of the fanwise melanin rods. Moreover, the widely spreading reflection from the barbules may occur because of the fanwise melanin rod arrangement.

  16. Pediatric cataract, myopic astigmatism, familial exudative vitreoretinopathy and primary open-angle glaucoma co-segregating in a family

    PubMed Central

    Hewitt, A.W.; Ruddle, J.B.; Vote, B.; Buttery, R.G.; Toomes, C.; Metlapally, R.; Li, Y.J.; Tran-Viet, K.N.; Malecaze, F.; Calvas, P.; Rosenberg, T.; Guggenheim, J.A.; Young, T.L.

    2011-01-01

    Purpose To describe an Australian pedigree of European descent with a variable autosomal dominant phenotype of: pediatric cortical cataract (CC), asymmetric myopia with astigmatism, familial exudative vitreoretinopathy (FEVR), and primary open-angle glaucoma (POAG). Methods Probands with CC, FEVR, and POAG were enrolled in three independent genetic eye studies in Tasmania. Genealogy confirmed these individuals were closely related and subsequent examination revealed 11 other family members with some or all of the associated disorders. Results Twelve individuals had CC thought to be of childhood onset, with one child demonstrating progressive lenticular opacification. One individual had severe retinal detachment while five others had dragged retinal vessels. Seven individuals had POAG. Seven individuals had myopia in at least one eye ≤-3 Diopters. DNA testing excluded mutations in myocilin, trabecular meshwork inducible glucocorticoid response (MYOC) and tetraspanin 12 (TSPAN12). Haplotype analysis excluded frizzled family receptor 4 (FZD4) and low density lipoprotein receptor-related protein 5 (LRP5), but only partly excluded EVR3. Multipoint linkage analysis revealed multiple chromosomal single-nucleotide polymorphisms (SNPs) of interest, but no statistically significant focal localization. Conclusions This unusual clustering of ophthalmic diseases suggests a possible single genetic cause for an apparently new cataract syndrome. This family’s clinical ocular features may reflect the interplay between retinal disease with lenticular changes and axial length in the development of myopia and glaucoma. PMID:21850187

  17. Pediatric cataract, myopic astigmatism, familial exudative vitreoretinopathy and primary open-angle glaucoma co-segregating in a family.

    PubMed

    Mackey, D A; Hewitt, A W; Ruddle, J B; Vote, B; Buttery, R G; Toomes, C; Metlapally, R; Li, Y J; Tran-Viet, K N; Malecaze, F; Calvas, P; Rosenberg, T; Guggenheim, J A; Young, T L

    2011-01-01

    To describe an Australian pedigree of European descent with a variable autosomal dominant phenotype of: pediatric cortical cataract (CC), asymmetric myopia with astigmatism, familial exudative vitreoretinopathy (FEVR), and primary open-angle glaucoma (POAG). Probands with CC, FEVR, and POAG were enrolled in three independent genetic eye studies in Tasmania. Genealogy confirmed these individuals were closely related and subsequent examination revealed 11 other family members with some or all of the associated disorders. Twelve individuals had CC thought to be of childhood onset, with one child demonstrating progressive lenticular opacification. One individual had severe retinal detachment while five others had dragged retinal vessels. Seven individuals had POAG. Seven individuals had myopia in at least one eye ≤-3 Diopters. DNA testing excluded mutations in myocilin, trabecular meshwork inducible glucocorticoid response (MYOC) and tetraspanin 12 (TSPAN12). Haplotype analysis excluded frizzled family receptor 4 (FZD4) and low density lipoprotein receptor-related protein 5 (LRP5), but only partly excluded EVR3. Multipoint linkage analysis revealed multiple chromosomal single-nucleotide polymorphisms (SNPs) of interest, but no statistically significant focal localization. This unusual clustering of ophthalmic diseases suggests a possible single genetic cause for an apparently new cataract syndrome. This family's clinical ocular features may reflect the interplay between retinal disease with lenticular changes and axial length in the development of myopia and glaucoma.

  18. Differential Association of Metabolic Risk Factors with Open Angle Glaucoma according to Obesity in a Korean Population

    PubMed Central

    Kim, Hyun-Ah; Han, Kyungdo; Lee, Yun-Ah; Choi, Jin A; Park, Yong-Moon

    2016-01-01

    The associations of the metabolic syndrome (MetS) with intraocular pressure and primary open angle glaucoma (OAG) have been reported. This study aimed to determine whether a difference in association exists between OAG and metabolic risk factors according to obesity status among Korean adults. A total of 8,816 participants (≥40 years) in the Korea National Health and Nutrition Examination Survey were classified into obese, body mass index (BMI) ≥ 25 kg/m2 and non-obese, BMI < 25 kg/m2. The prevalence of MetS was 40.1% in non-obese OAG and 66.0% in obese OAG. The prevalence of OAG increased with increasing number components for MetS in total population and in non-obese subjects (P < 0.001, respectively), while the prevalence of OAG was not associated with number of components for MetS in obese subjects (P = 0.14). In non-obese individuals, subjects with high triglycerides, high blood pressure (BP), and MetS were more likely to have OAG compared with those without high triglycerides, high BP, and MetS after adjusting for potential confounders. However, MetS or its components exhibited no significant association with glaucoma status in obese individuals. Our study provides understanding on the differences in association of OAG with MetS and its components according to obesity status. PMID:28004731

  19. Comparing approaches to screening for angle closure in older Chinese adults

    PubMed Central

    Andrews, J; Chang, D S; Jiang, Y; He, M; Foster, P J; Munoz, B; Kashiwagi, K; Friedman, D S

    2012-01-01

    Aims Primary angle-closure glaucoma is expected to account for nearly 50% of bilateral glaucoma blindness by 2020. This study was conducted to assess the performance of the scanning peripheral anterior chamber depth analyzer (SPAC) and limbal anterior chamber depth (LACD) as screening methods for angle closure. Methods This study assessed two clinical populations to compare SPAC, LACD, and gonioscopy: the Zhongshan Angle-closure Prevention Trial, from which 370 patients were eligible as closed-angle participants and the Liwan Eye Study, from which 72 patients were selected as open-angle controls. Eligible participants were assessed by SPAC, LACD, and gonioscopy. Results Angle status was defined by gonioscopy. Area under the receiver operating characteristic curve (AUROC) for SPAC was 0.92 (0.89–0.95) whereas AUROC for LACD was 0.94 (0.92–0.97). Using conventional cutoff points, sensitivity/specificity was 93.0%/70.8% for SPAC and 94.1%/87.5% for LACD. Sequential testing using both SPAC and LACD increased the specificity to 94.4% and decreased the sensitivity to 87.0%. Conclusion SPAC has significantly lower specificity than LACD measurement using conventional cutoffs but interpretation of the findings can be performed by modestly trained personnel. PMID:21997356

  20. Association of Interleukin-1 gene clusters polymorphisms with primary open-angle glaucoma: a meta-analysis.

    PubMed

    Li, Junhua; Feng, Yifan; Sung, Mi Sun; Lee, Tae Hee; Park, Sang Woo

    2017-11-28

    Previous studies have associated the Interleukin-1 (IL-1) gene clusters polymorphisms with the risk of primary open-angle glaucoma (POAG). However, the results were not consistent. Here, we performed a meta-analysis to evaluate the role of IL-1 gene clusters polymorphisms in POAG susceptibility. PubMed, EMBASE and Cochrane Library (up to July 15, 2017) were searched by two independent investigators. All case-control studies investigating the association between single-nucleotide polymorphisms (SNPs) of IL-1 gene clusters and POAG risk were included. Odds ratios (ORs) with 95% confidence intervals (CIs) were calculated for quantifying the strength of association that has been involved in at least two studies. Five studies on IL-1β rs16944 (c. -511C > T) (1053 cases and 986 controls), 4 studies on IL-1α rs1800587 (c. -889C > T) (822 cases and 714 controls), and 4 studies on IL-1β rs1143634 (c. +3953C > T) (798 cases and 730 controls) were included. The results suggest that all three SNPs were not associated with POAG risk. Stratification analyses indicated that the rs1143634 has a suggestive associated with high tension glaucoma (HTG) under dominant (P = 0.03), heterozygote (P = 0.04) and allelic models (P = 0.02), however, the weak association was nullified after Bonferroni adjustments for multiple tests. Based on current meta-analysis, we indicated that there is lack of association between the three SNPs of IL-1 and POAG. However, this conclusion should be interpreted with caution and further well designed studies with large sample-size are required to validate the conclusion as low statistical powers.

  1. The Prevalence of Open-Angle Glaucoma by Age in Myopia: The Korea National Health and Nutrition Examination Survey.

    PubMed

    Shim, Seong Hee; Sung, Kyung Rim; Kim, Joon Mo; Kim, Hyun Tae; Jeong, Jinho; Kim, Chan Yun; Lee, Mi Yeon; Park, Ki Ho

    2017-01-01

    To investigate the prevalence of open-angle glaucoma (OAG) in myopia by age. A cross-sectional study using a stratified, multistage, probability cluster survey. Participants in the Korean National Health and Nutrition Examination Survey between 2010 and 2011 were included. A standardized protocol was used to interview every participant and perform comprehensive ophthalmic examinations. Glaucoma was diagnosed according to the International Society of Geographical and Epidemiological Ophthalmology (ISGEO) criteria. After adjusting for age and sex, there was a positive correlation between OAG prevalence and increasing myopic refractive error except in participants with hyperopia. Younger participants with higher myopic refractive error had higher OAG prevalence than older participants with lower myopic refractive error. Participants with high myopia (OR 3.90, 95% confidence interval (CI) 2.30-6.59) had significantly greater age- and sex-adjusted odd ratios (ORs) than did those with emmetropia who were younger than 60 years. These data suggest that OAG develops earlier in participants with high myopia than in others. There was a high prevalence of OAG in participants with high myopia, even in those 19-29 years of age. Therefore, OAG screening should be performed earlier in participants with high myopia than is suggested by traditional guidelines.

  2. Kinematics of reflections in subsurface offset and angle-domain image gathers

    NASA Astrophysics Data System (ADS)

    Dafni, Raanan; Symes, William W.

    2018-05-01

    Seismic migration in the angle-domain generates multiple images of the earth's interior in which reflection takes place at different scattering-angles. Mechanically, the angle-dependent reflection is restricted to happen instantaneously and at a fixed point in space: Incident wave hits a discontinuity in the subsurface media and instantly generates a scattered wave at the same common point of interaction. Alternatively, the angle-domain image may be associated with space-shift (regarded as subsurface offset) extended migration that artificially splits the reflection geometry. Meaning that, incident and scattered waves interact at some offset distance. The geometric differences between the two approaches amount to a contradictory angle-domain behaviour, and unlike kinematic description. We present a phase space depiction of migration methods extended by the peculiar subsurface offset split and stress its profound dissimilarity. In spite of being in radical contradiction with the general physics, the subsurface offset reveals a link to some valuable angle-domain quantities, via post-migration transformations. The angle quantities are indicated by the direction normal to the subsurface offset extended image. They specifically define the local dip and scattering angles if the velocity at the split reflection coordinates is the same for incident and scattered wave pairs. Otherwise, the reflector normal is not a bisector of the opening angle, but of the corresponding slowness vectors. This evidence, together with the distinguished geometry configuration, fundamentally differentiates the angle-domain decomposition based on the subsurface offset split from the conventional decomposition at a common reflection point. An asymptotic simulation of angle-domain moveout curves in layered media exposes the notion of split versus common reflection point geometry. Traveltime inversion methods that involve the subsurface offset extended migration must accommodate the split geometry

  3. Open innovation in early drug discovery: roadmaps and roadblocks.

    PubMed

    Reichman, Melvin; Simpson, Peter B

    2016-05-01

    Open innovation in pharmaceutical R&D evolved from a triple helix of convergent paradigm shifts in academic, industrial and government research sectors. The birth of the biotechnology sector catalyzed shifts in location dynamics that led to the first wave of open innovation in pharmaceutical R&D between big pharma and startup companies. The National Institutes of Health (NIH) Roadmap was a crucial inflection point that set the stage for a new wave of open innovation models between pharmaceutical companies and universities that have the potential to transform the pharmaceutical R&D landscape. We highlight the attributes of leading protected open innovation models that foster the sharing of proprietary small molecule collections by lowering the risk of premature escape of intellectual property, particularly structure-activity data. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Hallux Valgus Correction Comparing Percutaneous Chevron/Akin (PECA) and Open Scarf/Akin Osteotomies.

    PubMed

    Lee, Moses; Walsh, James; Smith, Margaret M; Ling, Jeff; Wines, Andrew; Lam, Peter

    2017-08-01

    Minimally invasive surgery is being used increasingly, including for hallux valgus surgery. Despite the growing interest in minimally invasive procedures, there have been few publications on percutaneous chevron/akin (PECA) procedures, and no studies have been published comparing PECA to open scarf/akin osteotomies (SA). This was a prospective, randomized study of 50 patients undergoing operative correction of hallux valgus using one of 2 techniques (PECA vs open SA). Data were collected preoperatively and on 1 day, 2 weeks, 6 weeks, and 6 months postoperatively. Outcome measures include the American Orthopaedic Foot & Ankle Society Hallux-Metatarsophalangeal-Interphalangeal (AOFAS-HMI) Score, visual analog pain score, hallux valgus angle (HVA), and 1-2 intermetatarsal angle (IMA). Twenty-five patients underwent PECA procedures and 25 patients received SA procedures. Both groups showed significantly improved AOFAS-HMI scores after surgery (PECA group: 61.8 to 88.9, SA group: 57.3 to 84.1, P = .560) with comparable final scores. HVA and IMA also presented similar outcomes at final follow-up ( P = .520 and P = .270, respectively). However, the PECA group showed significantly lower pain level (VAS) in the early postoperative phase (postoperative day 1 to postoperative week 6, P < .001 and P = .004, respectively). No serious complications were observed in either group. Both groups showed comparable good to excellent clinical and radiologic outcomes at final follow-up. However, the PECA group had significantly less pain in the first 6 weeks following surgery. Level of Evidence Level II, prospective comparative study.

  5. Exclusive Backward-Angle Omega Meson Electroproduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wenliang, Li

    of σ T dominance, promising indications of the applicability of the TDA factorization are demonstrated at a much lower Q 2 value than its preferred range of Q 2 > 10 GeV 2. These studies have opened a new means to study the transition of the nucleon wavefunction through backward-angle experimental observables.« less

  6. Measuring charged particle multiplicity with early ATLAS public data

    NASA Astrophysics Data System (ADS)

    Üstün, G.; Barut, E.; Bektaş, E.; Özcan, V. E.

    2017-07-01

    We study 100 images of early LHC collisions that were recorded by the ATLAS experiment and made public for outreach purposes, and extract the charged particle multiplicity as a function of momentum for proton-proton collisions at a centre-of-mass energy of 7 TeV. As these collisions have already been pre-processed by the ATLAS Collaboration, the particle tracks are visible, but are available to the public only in the form of low-resolution bitmaps. We describe two separate image processing methods, one based on the industry-standard OpenCV library and C++, another based on self-developed algorithms in Python. We present our analysis of the transverse momentum and azimuthal angle distributions of the particles, in agreement with the literature.

  7. EP3/FP dual receptor agonist ONO-9054 administered morning or evening to patients with open-angle glaucoma or ocular hypertension: results of a randomised crossover study

    PubMed Central

    Berlin, Michael S; Rowe-Rendleman, Cheryl; Ahmed, Ike; Ross, Douglas T; Fujii, Akifumi; Ouchi, Takafumi; Quach, Christine; Wood, Andrew; Ward, Caroline L

    2016-01-01

    Background/aims The novel prostaglandin E (EP) 3 and prostaglandin F (FP) receptor agonist ONO-9054 is effective in lowering intraocular pressure (IOP) in patients with ocular hypertension and open-angle glaucoma when administered once daily. This study compares the effects of morning (AM) versus evening (PM) dosing of ONO-9054 on tolerability and IOP lowering. Methods This was a single-centre, randomised, double-masked, two-sequence, placebo-controlled crossover study in 12 subjects with bilateral primary open-angle glaucoma or ocular hypertension. Two 14-day crossover regimens were separated by a 2-week washout: ONO-9054 (1 drop to each eye) in the morning (07:00) and vehicle in the evening (19:00) and vice versa. IOP was measured multiple times during select days. Ocular examinations also evaluated safety and tolerability. Results Mild ocular hyperaemia, reported by six subjects with PM dosing, was the most frequent adverse event. Mild to moderate dryness was also slightly more frequent after PM dosing. Maximum IOP reduction from baseline occurred on day 2 with decreases from baseline of −7.4 mm Hg (−30.8%) for AM dosing and −9.1 mm Hg, (−38.0%) for PM dosing; after 14 days, mean reduction in IOP was −6.8 mm Hg (−28.6%) for AM dosing and −7.5 mm Hg (−31.0%) for PM dosing. Conclusions PM dosing of ONO-0954 was associated with a slightly increased frequency of mild hyperaemia and mild to moderate dryness. Both dosing schedules provided sustained reduction in IOP. Trial registration number NCT01670266. PMID:26453641

  8. Ultra-Wideband Angle-of-Arrival Tracking Systems

    NASA Technical Reports Server (NTRS)

    Arndt, G. Dickey; Ngo, Phong H.; Phan, Chau T.; Gross, Julia; Ni, Jianjun; Dusl, John

    2010-01-01

    Systems that measure the angles of arrival of ultra-wideband (UWB) radio signals and perform triangulation by use of those angles in order to locate the sources of those signals are undergoing development. These systems were originally intended for use in tracking UWB-transmitter-equipped astronauts and mobile robots on the surfaces of remote planets during early stages of exploration, before satellite-based navigation systems become operational. On Earth, these systems could be adapted to such uses as tracking UWB-transmitter-equipped firefighters inside buildings or in outdoor wildfire areas obscured by smoke. The same characteristics that have made UWB radio advantageous for fine resolution ranging, covert communication, and ground-penetrating radar applications in military and law-enforcement settings also contribute to its attractiveness for the present tracking applications. In particular, the waveform shape and the short duration of UWB pulses make it possible to attain the high temporal resolution (of the order of picoseconds) needed to measure angles of arrival with sufficient precision, and the low power spectral density of UWB pulses enables UWB radio communication systems to operate in proximity to other radio communication systems with little or no perceptible mutual interference.

  9. Relationship between visual field progression and baseline refraction in primary open-angle glaucoma.

    PubMed

    Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Umeda, Yuzo; Shiraga, Fumio

    2016-01-01

    To analyze the relationship between visual field (VF) progression and baseline refraction in Japanese patients with primary open-angle glaucoma (POAG) including normal-tension glaucoma. In this retrospective study, the subjects were patients with POAG who had undergone VF tests at least ten times with a Humphrey Field Analyzer (Swedish interactive thresholding algorithm standard, Central 30-2 program). VF progression was defined as a significantly negative value of mean deviation (MD) slope at the final VF test. Multivariate logistic regression models were applied to detect an association between MD slope deterioration and baseline refraction. A total of 156 eyes of 156 patients were included in this analysis. Significant deterioration of MD slope was observed in 70 eyes of 70 patients (44.9%), whereas no significant deterioration was evident in 86 eyes of 86 patients (55.1%). The eyes with VF progression had significantly higher baseline refraction compared to those without apparent VF progression (-1.9±3.8 diopter [D] vs -3.5±3.4 D, P=0.0048) (mean ± standard deviation). When subject eyes were classified into four groups by the level of baseline refraction applying spherical equivalent (SE): no myopia (SE > -1D), mild myopia (-1D ≥ SE > -3D), moderate myopia (-3D ≥ SE > -6D), and severe myopia (-6D ≥ SE), the Cochran-Armitage trend analysis showed a decreasing trend in the proportion of MD slope deterioration with increasing severity of myopia (P=0.0002). The multivariate analysis revealed that baseline refraction (P=0.0108, odds ratio [OR]: 1.13, 95% confidence interval [CI]: 1.03-1.25) and intraocular pressure reduction rate (P=0.0150, OR: 0.97, 95% CI: 0.94-0.99) had a significant association with MD slope deterioration. In the current analysis of Japanese patients with POAG, baseline refraction was a factor significantly associated with MD slope deterioration as well as intraocular pressure reduction rate. When baseline refraction was classified into

  10. 3. Elevation view of entire midsection using ultrawide angle lens. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Elevation view of entire midsection using ultrawide angle lens. Note opened south doors and closed north doors. The following photo WA-203-C-4 is similar except the camera position was moved right to include the slope of the south end. - Puget Sound Naval Shipyard, Munitions Storage Bunker, Naval Ammunitions Depot, South of Campbell Trail, Bremerton, Kitsap County, WA

  11. A new angle on microscopic suspension feeders near boundaries.

    PubMed

    Pepper, Rachel E; Roper, Marcus; Ryu, Sangjin; Matsumoto, Nobuyoshi; Nagai, Moeto; Stone, Howard A

    2013-10-15

    Microscopic sessile suspension feeders are a critical component in aquatic ecosystems, acting as an intermediate trophic stage between bacteria and higher eukaryotic taxa. Because they live attached to boundaries, it has long been thought that recirculation of the feeding currents produced by sessile suspension feeders inhibits their ability to access fresh fluid. However, previous models for the feeding flows of these organisms assume that they feed by pushing fluid perpendicular to surfaces they live upon, whereas we observe that sessile suspension feeders often feed at an angle to these boundaries. Using experiments and calculations, we show that living suspension feeders (Vorticella) likely actively regulate the angle that they feed relative to a substratum. We then use theory and simulations to show that angled feeding increases nutrient and particle uptake by reducing the reprocessing of depleted water. This work resolves an open question of how a key class of suspension-feeding organisms escapes physical limitations associated with their sessile lifestyle. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  12. An Open Letter to Premier Wen Jiabao

    ERIC Educational Resources Information Center

    Chinese Education and Society, 2008

    2008-01-01

    This article is an open letter of a group of early childhood education (ECE) practitioners to Premier Wen Jiabao. This open letter was written with one goal in mind: to ask Premier Wen's government to take measures to protect young children and support early childhood education. These practitioners have become worried about the many accidents that…

  13. The directivity of the sound radiation from panels and openings.

    PubMed

    Davy, John L

    2009-06-01

    This paper presents a method for calculating the directivity of the radiation of sound from a panel or opening, whose vibration is forced by the incidence of sound from the other side. The directivity of the radiation depends on the angular distribution of the incident sound energy in the room or duct in whose wall or end the panel or opening occurs. The angular distribution of the incident sound energy is predicted using a model which depends on the sound absorption coefficient of the room or duct surfaces. If the sound source is situated in the room or duct, the sound absorption coefficient model is used in conjunction with a model for the directivity of the sound source. For angles of radiation approaching 90 degrees to the normal to the panel or opening, the effect of the diffraction by the panel or opening, or by the finite baffle in which the panel or opening is mounted, is included. A simple empirical model is developed to predict the diffraction of sound into the shadow zone when the angle of radiation is greater than 90 degrees to the normal to the panel or opening. The method is compared with published experimental results.

  14. Changes of visual-field global indices after cataract surgery in primary open-angle glaucoma patients.

    PubMed

    Seol, Bo Ram; Jeoung, Jin Wook; Park, Ki Ho

    2016-11-01

    To determine changes of visual-field (VF) global indices after cataract surgery and the factors associated with the effect of cataracts on those indices in primary open-angle glaucoma (POAG) patients. A retrospective chart review of 60 POAG patients who had undergone phacoemulsification and intraocular lens insertion was conducted. All of the patients were evaluated with standard automated perimetry (SAP; 30-2 Swedish interactive threshold algorithm; Carl Zeiss Meditec Inc.) before and after surgery. VF global indices before surgery were compared with those after surgery. The best-corrected visual acuity, intraocular pressure (IOP), number of glaucoma medications before surgery, mean total deviation (TD) values, mean pattern deviation (PD) value, and mean TD-PD value were also compared with the corresponding postoperative values. Additionally, postoperative peak IOP and mean IOP were evaluated. Univariate and multivariate logistic regression analyses were performed to identify the factors associated with the effect of cataract on global indices. Mean deviation (MD) after cataract surgery was significantly improved compared with the preoperative MD. Pattern standard deviation (PSD) and visual-field index (VFI) after surgery were similar to those before surgery. Also, mean TD and mean TD-PD were significantly improved after surgery. The posterior subcapsular cataract (PSC) type showed greater MD changes than did the non-PSC type in both the univariate and multivariate logistic regression analyses. In the univariate logistic regression analysis, the preoperative TD-PD value and type of cataract were associated with MD change. However, in the multivariate logistic regression analysis, type of cataract was the only associated factor. None of the other factors was associated with MD change. MD was significantly affected by cataracts, whereas PSD and VFI were not. Most notably, the PSC type showed better MD improvement compared with the non-PSC type after cataract surgery

  15. Application of high intensity focused ultrasound for treatment of open-angle glaucoma in Indian patients.

    PubMed

    Deb-Joardar, Nilanjana; Reddy, Kasu Prasad

    2018-04-01

    The aim of this study is to assess the efficacy of ultrasound cycloplasty (UCP) in Indian patients with open angle glaucoma (OAG). A prospective interventional study was designed to treat 73 eyes of 73 patients with OAG with the EyeOP1 device equipped with six miniaturized cylindrical piezoelectric transducers. Two treatment protocols of ultrasound delivery depending on exposure time (8 s and 10 s of shot per transducer) were used. Complete ophthalmic examination, ocular biometry and anterior segment optical coherence tomography were performed preoperatively and patients were followed up at day 1, day 7 and months 1, 2, 3, 6, and 12. The primary outcome measure was "successful" intraocular pressure (IOP) control defined as IOP reduction ≥20% from baseline and IOP value >5 mm Hg at the last follow-up visit. Secondary outcomes were the occurrence of complications and mean IOP during the follow-up period. In all patients, the mean IOP reduced from 23.5 ± 3.0 mmHg before treatment to 15.7 ± 5.4 mmHg at 12 months (P < 0.05). Successful IOP control after a single procedure was 78.3% (79% and 78% in the 8 s and 10 s groups, respectively) at 12 months. Overall, the mean IOP reduction achieved in responding patients was 41% (standard deviation = 12%). Notwithstanding minor side effects such as transient pain, anterior chamber reaction, and refractive error changes, no major intraoperative or postoperative complications (severe hypotony or phthisis) were observed during the follow-up. Our short-term results reveal that UCP is a simple, safe, and noninvasive procedure which enables to significantly reduce the IOP in patients with OAG. The study results in Indian eyes corroborate findings in earlier studies on Caucasian eyes.

  16. Hip arthroscopy versus open surgical dislocation for femoroacetabular impingement

    PubMed Central

    Zhang, Dagang; Chen, Long; Wang, Guanglin

    2016-01-01

    Abstract Background: This meta-analysis aims to evaluate the efficacy and safety of hip arthroscopy versus open surgical dislocation for treating femoroacetabular impingement (FAI) through published clinical trials. Methods: We conducted a comprehensive literature search using PUBMED, EMBASE, and the Cochrane Central Register of Controlled Trials databases for relevant studies on hip arthroscopy and open surgical dislocation as treatment options for FAI. Results: Compared with open surgical dislocation, hip arthroscopy resulted in significantly higher Nonarthritic Hip Scores (NAHS) at 3- and 12-month follow-ups, a significant improvement in NAHS from preoperation to 3 months postoperation, and a significantly lower reoperation rate. Open surgical dislocation resulted in a significantly improved alpha angle by the Dunn view in patients with cam osteoplasty from preoperation to postoperation, compared with hip arthroscopy. This meta-analysis demonstrated no significant differences in the modified Harris Hip Score, Hip Outcome Score-Activities of Daily Living, or Hip Outcome Score-Sport Specific Subscale at 12 months of follow-up, or in complications (including nerve damage, wound infection, and wound dehiscence). Conclusion: Hip arthroscopy resulted in higher NAHS and lower reoperation rates, but had less improvement in alpha angle in patients with cam osteoplasty, than open surgical dislocation. PMID:27741133

  17. Low-angle faulting in strike-slip dominated settings: Seismic evidence from the Maritimes Basin, Canada

    NASA Astrophysics Data System (ADS)

    Pinet, Nicolas; Dietrich, Jim; Duchesne, Mathieu J.; Hinds, Steve J.; Brake, Virginia

    2018-07-01

    The Maritimes Basin is an upper Paleozoic sedimentary basin centered in the Gulf of St. Lawrence (Canada). Early phases of basin formation included the development of partly connected sub-basins bounded by high-angle faults, in an overall strike-slip setting. Interpretation of reprocessed seismic reflection data indicates that a low-angle detachment contributed to the formation of a highly asymmetric sub-basin. This detachment was rotated toward a lower angle and succeeded by high-angle faults that sole into the detachment or cut it. This model bears similarities to other highly extended terranes and appears to be applicable to strike-slip and/or transtensional settings.

  18. Role of the water-drinking test in medically treated primary open angle glaucoma patients.

    PubMed

    Salcedo, H; Arciniega, D; Mayorga, M; Wu, L

    2018-05-01

    The water-drinking test (WDT) has recently re-emerged as a possible way to determine the competency of the trabecular meshwork. We performed a prospective interventional study to test the hypothesis that the WDT could be useful in assessing fluctuations in patients undergoing treatment for primary open angle glaucoma (POAG). We included 122 patients; 62 on medical treatment for POAG (n=123 eyes) and 60 controls (n=120 eyes). The study group had been on intraocular pressures (IOP) lowering treatment continuously for at least 3months with stable IOP. The WDT was performed during fasting and was considered positive if it fluctuated ≥6mmHg. The patients on medical treatment had a mean age of 50.56±18.45 years vs. 51.35±11.22 for the controls (P=0.34); with 71% being female in the study group and 77% in the control group. In the study group; 52% were on beta blockers (n=64), 27% combination of two or more medications (n=33), 19% prostaglandin analogues (n=24) and 2% alpha agonists (n=2). The WDT was positive in 17.07% (n=21) in the study group and 2.5% (n=3) in the control group (P=0.0001). The mean fluctuation was 7.14±2.15mmHg in the study group and 6.00±0mmHg in the controls (P=0.33). A positive WDT was found in 33.33% (n=11) of those on combination therapy; 12.5% (n=3) prostaglandin analogues and 10.94% (n=7) beta blockers (P=0.03). Combination therapy had the highest positive WDT fluctuation (7.54±2.87) followed by prostaglandin analogues (7.00±1.00) and beta blockers (6.57±0.78) with a P value of 0.44. The WDT can identify significant fluctuations in eyes with POAG that are medically treated. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  19. The Effect of Laser Trabeculoplasty on Posture-Induced Intraocular Pressure Changes in Patients with Open Angle Glaucoma

    PubMed Central

    Yang, Jee Myung; Sung, Mi Sun; Heo, Hwan; Park, Sang Woo

    2016-01-01

    Purpose To investigate the effect of argon laser trabeculoplasty (ALT) on posture-induced intraocular pressure (IOP) changes in patients with open angle glaucoma (OAG). Methods Thirty eyes of 30 consecutive patients with OAG who underwent ALT were prospectively analyzed. The IOP was measured using Icare PRO in the sitting position, supine position, and dependent lateral decubitus position (DLDP) before ALT and at 1 week, 1 month, 2 months, and 3 months after ALT. Results Compared to the baseline values, the IOP in each position was significantly decreased after ALT (all P < 0.001). During follow-up, the mean percentage of IOP reduction was similar in the sitting and supine positions, but was significantly lower in DLDP than in the sitting or supine positions (all P < 0.05). In terms of postural IOP changes, the IOP in the supine position and DLDP was significantly higher than that in the sitting position at the same time points during the follow-up period (all P < 0.001). The difference between the IOP in the supine position and DLDP during follow-up was significant (all P < 0.001). The extent of IOP differences between any positions did not show significant changes during the follow-up period (all P > 0.05). Conclusions ALT appears to be effective in lowering the IOP in various body positions, but the degree of this effect was significantly lower in DLDP. In addition, ALT seemed to have limited effects on posture-induced IOP changes. PMID:26807852

  20. Apparent contact angle and contact angle hysteresis on liquid infused surfaces.

    PubMed

    Semprebon, Ciro; McHale, Glen; Kusumaatmaja, Halim

    2016-12-21

    We theoretically investigate the apparent contact angle and contact angle hysteresis of a droplet placed on a liquid infused surface. We show that the apparent contact angle is not uniquely defined by material parameters, but also has a dependence on the relative size between the droplet and its surrounding wetting ridge formed by the infusing liquid. We derive a closed form expression for the contact angle in the limit of vanishing wetting ridge, and compute the correction for small but finite ridge, which corresponds to an effective line tension term. We also predict contact angle hysteresis on liquid infused surfaces generated by the pinning of the contact lines by the surface corrugations. Our analytical expressions for both the apparent contact angle and contact angle hysteresis can be interpreted as 'weighted sums' between the contact angles of the infusing liquid relative to the droplet and surrounding gas phases, where the weighting coefficients are given by ratios of the fluid surface tensions.

  1. Open-ocean fish reveal an omnidirectional solution to camouflage in polarized environments.

    PubMed

    Brady, Parrish C; Gilerson, Alexander A; Kattawar, George W; Sullivan, James M; Twardowski, Michael S; Dierssen, Heidi M; Gao, Meng; Travis, Kort; Etheredge, Robert Ian; Tonizzo, Alberto; Ibrahim, Amir; Carrizo, Carlos; Gu, Yalong; Russell, Brandon J; Mislinski, Kathryn; Zhao, Shulei; Cummings, Molly E

    2015-11-20

    Despite appearing featureless to our eyes, the open ocean is a highly variable environment for polarization-sensitive viewers. Dynamic visual backgrounds coupled with predator encounters from all possible directions make this habitat one of the most challenging for camouflage. We tested open-ocean crypsis in nature by collecting more than 1500 videopolarimetry measurements from live fish from distinct habitats under a variety of viewing conditions. Open-ocean fish species exhibited camouflage that was superior to that of both nearshore fish and mirrorlike surfaces, with significantly higher crypsis at angles associated with predator detection and pursuit. Histological measurements revealed that specific arrangements of reflective guanine platelets in the fish's skin produce angle-dependent polarization modifications for polarocrypsis in the open ocean, suggesting a mechanism for natural selection to shape reflectance properties in this complex environment. Copyright © 2015, American Association for the Advancement of Science.

  2. Passive rejection of heat from an isotope heat source through an open door

    NASA Technical Reports Server (NTRS)

    Burns, R. K.

    1971-01-01

    The isotope heat-source design for a Brayton power system includes a door in the thermal insulation through which the heat can be passively rejected to space when the power system is not operating. The results of an analysis to predict the heat-source surface temperature and the heat-source heat-exchanger temperature during passive heat rejection as a function of insulation door opening angle are presented. They show that for a door opening angle greater than 20 deg, the temperatures are less than the steady-state temperatures during power system operation.

  3. Comparative assessment of bone pose estimation using Point Cluster Technique and OpenSim.

    PubMed

    Lathrop, Rebecca L; Chaudhari, Ajit M W; Siston, Robert A

    2011-11-01

    Estimating the position of the bones from optical motion capture data is a challenge associated with human movement analysis. Bone pose estimation techniques such as the Point Cluster Technique (PCT) and simulations of movement through software packages such as OpenSim are used to minimize soft tissue artifact and estimate skeletal position; however, using different methods for analysis may produce differing kinematic results which could lead to differences in clinical interpretation such as a misclassification of normal or pathological gait. This study evaluated the differences present in knee joint kinematics as a result of calculating joint angles using various techniques. We calculated knee joint kinematics from experimental gait data using the standard PCT, the least squares approach in OpenSim applied to experimental marker data, and the least squares approach in OpenSim applied to the results of the PCT algorithm. Maximum and resultant RMS differences in knee angles were calculated between all techniques. We observed differences in flexion/extension, varus/valgus, and internal/external rotation angles between all approaches. The largest differences were between the PCT results and all results calculated using OpenSim. The RMS differences averaged nearly 5° for flexion/extension angles with maximum differences exceeding 15°. Average RMS differences were relatively small (< 1.08°) between results calculated within OpenSim, suggesting that the choice of marker weighting is not critical to the results of the least squares inverse kinematics calculations. The largest difference between techniques appeared to be a constant offset between the PCT and all OpenSim results, which may be due to differences in the definition of anatomical reference frames, scaling of musculoskeletal models, and/or placement of virtual markers within OpenSim. Different methods for data analysis can produce largely different kinematic results, which could lead to the misclassification

  4. Wide-angle display developments by computer graphics

    NASA Technical Reports Server (NTRS)

    Fetter, William A.

    1989-01-01

    Computer graphics can now expand its new subset, wide-angle projection, to be as significant a generic capability as computer graphics itself. Some prior work in computer graphics is presented which leads to an attractive further subset of wide-angle projection, called hemispheric projection, to be a major communication media. Hemispheric film systems have long been present and such computer graphics systems are in use in simulators. This is the leading edge of capabilities which should ultimately be as ubiquitous as CRTs (cathode-ray tubes). These assertions are not from degrees in science or only from a degree in graphic design, but in a history of computer graphics innovations, laying groundwork by demonstration. The author believes that it is timely to look at several development strategies, since hemispheric projection is now at a point comparable to the early stages of computer graphics, requiring similar patterns of development again.

  5. Automated analysis of angle closure from anterior chamber angle images.

    PubMed

    Baskaran, Mani; Cheng, Jun; Perera, Shamira A; Tun, Tin A; Liu, Jiang; Aung, Tin

    2014-10-21

    To evaluate a novel software capable of automatically grading angle closure on EyeCam angle images in comparison with manual grading of images, with gonioscopy as the reference standard. In this hospital-based, prospective study, subjects underwent gonioscopy by a single observer, and EyeCam imaging by a different operator. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. An eye was classified as having angle closure if there were two or more quadrants of closure. Automated grading of the angle images was performed using customized software. Agreement between the methods was ascertained by κ statistic and comparison of area under receiver operating characteristic curves (AUC). One hundred forty subjects (140 eyes) were included, most of whom were Chinese (102/140, 72.9%) and women (72/140, 51.5%). Angle closure was detected in 61 eyes (43.6%) with gonioscopy in comparison with 59 eyes (42.1%, P = 0.73) using manual grading, and 67 eyes (47.9%, P = 0.24) with automated grading of EyeCam images. The agreement for angle closure diagnosis between gonioscopy and both manual (κ = 0.88; 95% confidence interval [CI), 0.81-0.96) and automated grading of EyeCam images was good (κ = 0.74; 95% CI, 0.63-0.85). The AUC for detecting eyes with gonioscopic angle closure was comparable for manual and automated grading (AUC 0.974 vs. 0.954, P = 0.31) of EyeCam images. Customized software for automated grading of EyeCam angle images was found to have good agreement with gonioscopy. Human observation of the EyeCam images may still be needed to avoid gross misclassification, especially in eyes with extensive angle closure. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  6. Two-Year COMPASS Trial Results: Supraciliary Microstenting with Phacoemulsification in Patients with Open-Angle Glaucoma and Cataracts.

    PubMed

    Vold, Steven; Ahmed, Iqbal Ike K; Craven, E Randy; Mattox, Cynthia; Stamper, Robert; Packer, Mark; Brown, Reay H; Ianchulev, Tsontcho

    2016-10-01

    We evaluated 2-year safety and efficacy of supraciliary microstenting (CyPass Micro-Stent; Transcend Medical, Inc., Menlo Park, CA) for treating mild-to-moderate primary open-angle glaucoma (POAG) in patients undergoing cataract surgery. Multicenter (24 US sites), interventional randomized clinical trial (RCT) (ClinicalTrials.gov identifier, NCT01085357). Subjects were enrolled beginning July 2011, with study completion in March 2015. Subjects had POAG with mean diurnal unmedicated intraocular pressure (IOP) 21-33 mmHg and were undergoing phacoemulsification cataract surgery. After completing cataract surgery, subjects were intraoperatively randomized to phacoemulsification only (control) or supraciliary microstenting with phacoemulsification (microstent) groups (1:3 ratio). Microstent implantation via an ab interno approach to the supraciliary space allowed concomitant cataract and glaucoma surgery. Outcome measures included percentage of subjects achieving ≥20% unmedicated diurnal IOP lowering versus baseline, mean IOP change and glaucoma medication use, and ocular adverse event (AE) incidence through 24 months. Of 505 subjects, 131 were randomized to the control group and 374 were randomized to the microstent group. Baseline mean IOPs in the control and microstent groups were similar: 24.5±3.0 and 24.4±2.8 mmHg, respectively (P > 0.05); mean medications were 1.3±1.0 and 1.4±0.9, respectively (P > 0.05). There was early and sustained IOP reduction, with 60% of controls versus 77% of microstent subjects achieving ≥20% unmedicated IOP lowering versus baseline at 24 months (P = 0.001; per-protocol analysis). Mean IOP reduction was ↓7.4 mmHg for the microstent group versus ↓5.4 mmHg in controls (P < 0.001), with 85% of microstent subjects not requiring IOP medications at 24 months. Mean 24-month medication use was 67% lower in microstent subjects (P < 0.001); 59% of control versus 85% of microstent subjects were medication free. Mean medication use in

  7. A multicenter, retrospective chart review study comparing index therapy change rates in open-angle glaucoma or ocular hypertension patients newly treated with latanoprost or travoprost-Z monotherapy.

    PubMed

    Fain, Joel M; Kotak, Sameer; Mardekian, Jack; Bacharach, Jason; Edward, Deepak P; Rauchman, Steven; Brevetti, Teresa; Fox, Janet L; Lovelace, Cherie

    2011-06-13

    Because latanoprost and the original formulation of travoprost that included benzalkonium chloride (BAK) have been shown to be similar with regard to tolerability, we compared initial topical intraocular pressure (IOP)-lowering medication change rates in patients newly treated with latanoprost or travoprost-Z monotherapy. At 14 clinical practice sites, medical records were abstracted for patients with a diagnosis of open-angle glaucoma or ocular hypertension and who were ≥40 years of age, had a baseline and at least one follow-up visit, and had no prior history of ocular prostaglandin use. Data regarding demographics, ocular/systemic medical histories, clinical variables, therapy initiations and reasons for changes, adverse events, and resource utilization were recorded from randomly chosen eligible charts. Primary outcomes were rates of and reasons for changing from the initial therapy within six months and across the full study period (1000 days). Data from 900 medical charts (latanoprost, 632; travoprost-Z, 268) were included. For both cohorts, average follow-up was >1 year. Cohorts were similar with regard to age (median ~67 years), gender distribution (>50% female), and diagnosis (~80% with open-angle glaucoma). Within six months, rates of index therapy change for latanoprost versus travoprost-Z were 21.2% (134/632) and 28.7% (77/268), respectively (p = 0.0148); across the full study period, rates were 34.5% (218/632) and 45.2% (121/268), respectively (p = 0.0026). Among those who changed their index therapy, insufficient IOP control was the most commonly reported reason followed by adverse events; hyperemia was the most commonly reported adverse event at index therapy change. In this "real world" study of changes in therapy in patients prescribed initial monotherapy with latanoprost with BAK or travoprost-Z with SofZia, medication changes were common in both treatment groups but statistically significantly more frequent with travoprost-Z.

  8. The human heart: application of the golden ratio and angle.

    PubMed

    Henein, Michael Y; Zhao, Ying; Nicoll, Rachel; Sun, Lin; Khir, Ashraf W; Franklin, Karl; Lindqvist, Per

    2011-08-04

    The golden ratio, or golden mean, of 1.618 is a proportion known since antiquity to be the most aesthetically pleasing and has been used repeatedly in art and architecture. Both the golden ratio and the allied golden angle of 137.5° have been found within the proportions and angles of the human body and plants. In the human heart we found many applications of the golden ratio and angle, in addition to those previously described. In healthy hearts, vertical and transverse dimensions accord with the golden ratio, irrespective of different absolute dimensions due to ethnicity. In mild heart failure, the ratio of 1.618 was maintained but in end-stage heart failure the ratio significantly reduced. Similarly, in healthy ventricles mitral annulus dimensions accorded with the golden ratio, while in dilated cardiomyopathy and mitral regurgitation patients the ratio had significantly reduced. In healthy patients, both the angles between the mid-luminal axes of the pulmonary trunk and the ascending aorta continuation and between the outflow tract axis and continuation of the inflow tract axis of the right ventricle approximate to the golden angle, although in severe pulmonary hypertension, the angle is significantly increased. Hence the overall cardiac and ventricular dimensions in a normal heart are consistent with the golden ratio and angle, representing optimum pump structure and function efficiency, whereas there is significant deviation in the disease state. These findings could have anatomical, functional and prognostic value as markers of early deviation from normality. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  9. Phacoemulsification combined with a new ab interno gel stent to treat open-angle glaucoma: Pilot study.

    PubMed

    Sheybani, Arsham; Lenzhofer, Markus; Hohensinn, Melchior; Reitsamer, Herbert; Ahmed, Iqbal Ike K

    2015-09-01

    To study the effect on intraocular pressure (IOP) of implanting a new gelatin stent at the time of cataract surgery in the treatment of open-angle glaucoma (OAG). Multicenter university and private-practice settings. Nonrandomized prospective clinical trial. The implantation of 2 models of a gelatin stent (Xen140 and Xen63) was performed at the time of cataract surgery without mitomycin-C. Complete success was defined as a postoperative IOP of less than 18 mm Hg and more than a 20% reduction in IOP at 12 months without glaucoma medication. Failure was defined as loss of light perception vision or worse, a need for additional glaucoma surgery, or less than a 20% reduction in the IOP from baseline. The study included 37 eyes of 37 patients. The mean preoperative IOP was 22.4 mm Hg ± 4.2 (SD) on 2.5 ± 1.4 medication classes. Twelve months postoperatively, the mean IOP was reduced to 15.4 ± 3.0 mm Hg on 0.9 ± 1.0 medication classes (P < .0001). This resulted in a qualified success of 85.3% and a complete success rate off medications of 47.1%. There were no failures. Cataract surgery combined with implantation of the gelatin stent resulted in a significant reduction in IOP in eyes with OAG. Dr. Sheybani has received travel reimbursement from Aquesys, Inc. Dr. Ahmed is a paid consultant to Aquesys, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. The impact of intraocular pressure reduction on retrobulbar hemodynamic parameters in patients with open-angle glaucoma.

    PubMed

    Marjanovic, Ivan; Milic, Natasa; Martinez, Antonio

    2012-01-01

    To assess the retrobulbar hemodynamic parameters in the ophthalmic artery (OA), central retinal artery (CRA), and short posterior ciliary arteries (PCA) after decreasing elevated intraocular pressure (IOP) in patients with open-angle glaucoma (OAG) by using color Doppler imaging. A total of 46 eyes from 46 patients with OAG, with elevated IOP, were consecutively included in this prospective study. Peak-systolic velocity, end-diastolic velocity, and Pourcelot resistivity index were assessed in the OA, CRA, and PCA. The IOP was measured with Goldmann applanation tonometer (GAT) and the dynamic contour tonometer (DCT), 3 times respectively. Ocular pulse amplitude (OPA) appeared during the DCT measurement. After decreasing the elevated IOP, measured with both GAT and DCT, the retrobulbar parameters showed no differences as compared with baseline measurements. After Bonferroni correction (p ≤ 0.0042, alpha/12), statistical significance appeared in retrobulbar hemodynamics only in DCT (29.3 ± 6.4 vs 15.5 ± 4.2 mmHg), GAT (33.0 ± 8.3 vs 15.8 ± 7.0 mmHg), and OPA measurements (4.1 ± 1.3 vs 2.7 ± 1.4 mmHg), in comparison to baseline. There was no correlation between the changes in IOP measured with either DCT or GAT and the changes in the retrobulbar hemodynamic parameters (p>0.05 for all). The results of our study suggested a lack of correlation between the changes in IOP, measured with either DCT or GAT, and the changes in the retrobulbar hemodynamic parameters. The results of our study might suggest that the blood flow disturbances found in glaucoma patients are independent of the IOP.

  11. Effect of trabeculectomy on the accuracy of intraocular lens calculations in patients with open-angle glaucoma.

    PubMed

    Bae, Hyoung Won; Lee, Yun Ha; Kim, Do Wook; Lee, Taekjune; Hong, Samin; Seong, Gong Je; Kim, Chan Yun

    2016-08-01

    The objective of the study is to examine the effect of trabeculectomy on intraocular lens power calculations in patients with open-angle glaucoma (OAG) undergoing cataract surgery. The design is retrospective data analysis. There are a total of 55 eyes of 55 patients with OAG who had a cataract surgery alone or in combination with trabeculectomy. We classified OAG subjects into the following groups based on surgical history: only cataract surgery (OC group), cataract surgery after prior trabeculectomy (CAT group), and cataract surgery performed in combination with trabeculectomy (CCT group). Differences between actual and predicted postoperative refractive error. Mean error (ME, difference between postoperative and predicted SE) in the CCT group was significantly lower (towards myopia) than that of the OC group (P = 0.008). Additionally, mean absolute error (MAE, absolute value of ME) in the CAT group was significantly greater than in the OC group (P = 0.006). Using linear mixed models, the ME calculated with the SRK II formula was more accurate than the ME predicted by the SRK T formula in the CAT (P = 0.032) and CCT (P = 0.035) groups. The intraocular lens power prediction accuracy was lower in the CAT and CCT groups than in the OC group. The prediction error was greater in the CAT group than in the OC group, and the direction of the prediction error tended to be towards myopia in the CCT group. The SRK II formula may be more accurate in predicting residual refractive error in the CAT and CCT groups. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  12. A mathematical method for precisely calculating the radiographic angles of the cup after total hip arthroplasty.

    PubMed

    Zhao, Jing-Xin; Su, Xiu-Yun; Xiao, Ruo-Xiu; Zhao, Zhe; Zhang, Li-Hai; Zhang, Li-Cheng; Tang, Pei-Fu

    2016-11-01

    We established a mathematical method to precisely calculate the radiographic anteversion (RA) and radiographic inclination (RI) angles of the acetabular cup based on anterior-posterior (AP) pelvic radiographs after total hip arthroplasty. Using Mathematica software, a mathematical model for an oblique cone was established to simulate how AP pelvic radiographs are obtained and to address the relationship between the two-dimensional and three-dimensional geometry of the opening circle of the cup. In this model, the vertex was the X-ray beam source, and the generatrix was the ellipse in radiographs projected from the opening circle of the acetabular cup. Using this model, we established a series of mathematical formulas to reveal the differences between the true RA and RI cup angles and the measurements results achieved using traditional methods and AP pelvic radiographs and to precisely calculate the RA and RI cup angles based on post-operative AP pelvic radiographs. Statistical analysis indicated that traditional methods should be used with caution if traditional measurements methods are used to calculate the RA and RI cup angles with AP pelvic radiograph. The entire calculation process could be performed by an orthopedic surgeon with mathematical knowledge of basic matrix and vector equations. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Light-sheet microscopy for everyone? Experience of building an OpenSPIM to study flatworm development.

    PubMed

    Girstmair, Johannes; Zakrzewski, Anne; Lapraz, François; Handberg-Thorsager, Mette; Tomancak, Pavel; Pitrone, Peter Gabriel; Simpson, Fraser; Telford, Maximilian J

    2016-06-30

    Selective plane illumination microscopy (SPIM a type of light-sheet microscopy) involves focusing a thin sheet of laser light through a specimen at right angles to the objective lens. As only the thin section of the specimen at the focal plane of the lens is illuminated, out of focus light is naturally absent and toxicity due to light (phototoxicity) is greatly reduced enabling longer term live imaging. OpenSPIM is an open access platform (Pitrone et al. 2013 and OpenSPIM.org) created to give new users step-by-step instructions on building a basic configuration of a SPIM microscope, which can in principle be adapted and upgraded to each laboratory's own requirements and budget. Here we describe our own experience with the process of designing, building, configuring and using an OpenSPIM for our research into the early development of the polyclad flatworm Maritigrella crozieri - a non-model animal. Our OpenSPIM builds on the standard design with the addition of two colour laser illumination for simultaneous detection of two probes/molecules and dual sided illumination, which provides more even signal intensity across a specimen. Our OpenSPIM provides high resolution 3d images and time lapse recordings, and we demonstrate the use of two colour lasers and the benefits of two color dual-sided imaging. We used our microscope to study the development of the embryo of the polyclad flatworm M. crozieri. The capabilities of our microscope are demonstrated by our ability to record the stereotypical spiral cleavage pattern of M. crozieri with high-speed multi-view time lapse imaging. 3D and 4D (3D + time) reconstruction of early development from these data is possible using image registration and deconvolution tools provided as part of the open source Fiji platform. We discuss our findings on the pros and cons of a self built microscope. We conclude that home-built microscopes, such as an OpenSPIM, together with the available open source software, such as MicroManager and

  14. Comparison of factors associated with occludable angle between american Caucasians and ethnic Chinese.

    PubMed

    Wang, Ye Elaine; Li, Yingjie; Wang, Dandan; He, Mingguang; Lin, Shan

    2013-11-21

    To determine if factors associated with gonioscopy-determined occludable angle among American Caucasians are similar to those found in ethnic Chinese. This is a prospective cross-sectional study with 120 American Caucasian, 116 American Chinese, and 116 mainland Chinese subjects. All three groups were matched for sex and age (40-80 years). Gonioscopy was performed for each subject (occludable angles = posterior trabecular meshwork not visible for ≥2 quadrants). Anterior segment optical coherence tomography and customized software was used to measure anterior segment biometry and iris parameters, including anterior chamber depth/width (ACD, ACW), lens vault (LV), and iris thickness/area/curvature. In both Chinese and Caucasians, eyes with occludable angles had smaller ACD and ACW, and larger LV and iris curvature than eyes with open angles (all P < 0.005). Chinese eyes had smaller ACD and ACW than Caucasian eyes (both P < 0.01) in the occludable angle cohort. Iris characteristics did not differ significantly between Chinese and Caucasians in the occludable angle cohort. Based on multivariate logistic regression, gonioscopy-determined occludable angle was significantly associated with LV, iris area, and sex (all P < 0.03) in Chinese; and with LV, ACD, iris thickness, age, and sex (all P < 0.04) in Caucasians. Several factors associated with occludable angle differed between Caucasians and Chinese, suggesting potentially different mechanisms in occludable angle development in the two racial groups. This is the first study to demonstrate that lens vault is an important anterior segment optical coherence tomography parameter in the screening for angle closure in Caucasians. In addition, iris thickness was a significant predictor for occludable angles in Caucasians but was not in ethnic Chinese.

  15. Glaucoma, Open-Angle

    MedlinePlus

    ... is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye ... Media Policies and Other Important Links NEI Employee Emergency Information NEI Intranet (Employees Only) *PDF files require ...

  16. Three-dimensional orientation and location-dependent varying rules of radiographic angles of the acetabular cup.

    PubMed

    Zhao, Jing-Xin; Su, Xiu-Yun; Zhao, Zhe; Xiao, Ruo-Xiu; Zhang, Li-Cheng; Tang, Pei-Fu

    2018-02-17

    The aim of this study is to demonstrate the varying rules of radiographic angles following varying three-dimensional (3D) orientations and locations of cup using an accurate mathematical model. A cone model is established to address the quantitative relationship between the opening circle of cup and its ellipse projection on radiograph. The varying rules of two-dimensional (2D) radiographic anteversion (RA) and inclination (RI) angles can be analyzed. When the centre of cup is located above X-ray source, with proper 3D RI/RA angles, 2D RA angle can be equal to its 3D counterpart, and 2D RI angle is usually greater than its 3D counterpart. Except for the original point on hip-centered anterior-posterior radiograph, there is no area on radiograph where both 2D RA and RI angles are equal to their 3D counterparts simultaneously. This study proposes an innovative model for accurately explaining how 2D RA/RI angles of cup are varying following different 3D RA/RI angles and location of cup. The analysis results provide clinicians an intuitive grasp of knowledge about 2D RA/RI angles greater or smaller than their 3D counterparts post-operatively. The established model may allow determining the effects of pelvic rotations on 2D radiographic angles of cup.

  17. Thermally Tunable Hydrogels Displaying Angle-Independent Structural Colors.

    PubMed

    Ohtsuka, Yumiko; Seki, Takahiro; Takeoka, Yukikazu

    2015-12-14

    We report the preparation of thermally tunable hydrogels displaying angle-independent structural colors. The porous structures were formed with short-range order using colloidal amorphous array templates and a small amount of carbon black (CB). The resultant porous hydrogels prepared using colloidal amorphous arrays without CB appeared white, whereas the hydrogels with CB revealed bright structural colors. The brightly colored hydrogels rapidly changed hues in a reversible manner, and the hues varied widely depending on the water temperature. Moreover, the structural colors were angle-independent under diffusive lighting because of the isotropic nanostructure generated from the colloidal amorphous arrays. © 2015 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA. This is an open access article under the terms of the Creative Commons Attribution Non-Commercial NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.

  18. Residual Stress Assessment in Thin Angle Ply Tubes

    NASA Astrophysics Data System (ADS)

    Kaddour, A. S.; Al-Hassani, S. T. S.; Hinton, M. J.

    2003-05-01

    This preliminary study aims to investigate the residual stresses developed in hot cured thin-walled angle-ply filament wound tubes made of E-glass/epoxy, Kevlar/epoxy and carbon/epoxy materials. The residual stresses were estimated from change in geometry of these tubes when axially slitted at ambient temperature. Three basic deformation modes; namely opening up, closing-in and twisting, were observed and these depended on the winding angle, material and wall thickness. The residual stresses were also determined from hoop and axial strain gauges mounted on both the inner and outer surfaces at various locations around the tube. The stresses were compared with theoretical prediction based upon a linear thermo-elastic analysis. Both the predicted and measured values were found to increase with increasing hoop stiffness but there was a large discrepancy between the predicted and measured data, reaching a factor of 5 for the thinnest case. When compared with predicted failure stresses, the experimentally determined stresses were some 15% of the computed compressive strength.

  19. Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy

    PubMed Central

    Balakrishna, Nagalla

    2017-01-01

    Aim To evaluate the configuration of the anterior chamber angle quantitatively and study the morphological changes in the eye with ultrasound biomicroscopy (UBM) in primary angle closure glaucoma (PACG) patients after laser peripheral iridotomy (LPI). Materials and methods A total of 185 eyes of 185 PACG patients post-LPI and 126 eyes of 126 normal subjects were included in this prospective study. All subjects underwent complete ophthalmic evaluation, A-scan biometry, and UBM. The anterior segment and angle parameters were measured quantitatively and compared in both groups using Student’s t-test. Results The PACG patients had shorter axial length, shallower central anterior chamber depth anterior chamber depth (ACD), and anteriorly located lens when compared with normal subjects. Trabecular iris angle (TIA) was significantly narrow (5.73 ± 7.76°) in patients with PACG when compared with normal subjects (23.75 ± 9.38°). The angle opening distance at 500 pm from scleral spur (AOD 500), trabecular-ciliary process distance (TCPD), iris-ciliary process distance (ICPD), and iris-zonule distance (IZD) were significantly shorter in patients with PACG than in normal subjects (p < 0.0001). The iris lens angle (ILA), scleral-iris angle (SIA), and scleral-ciliary process angle (SCPA) were significantly narrower in patients with PACG than in normal subjects (p < 0.0001). The iris-lens contact distance (ILCD) was greater in PACG group than in normal (p = 0.001). Plateau iris was seen in 57/185 (30.8%) of the eyes. Anterior positioned ciliary processes were seen in 130/185 eyes (70.3%) of eyes. Conclusion In PACG patients, persistent apposition angle closure is common even after LPI, which could be due to anterior rotation of ciliary body and plateau iris and overcrowding of anterior segment due to shorter axial length and relative anterior lens position. How to cite this article: Mansoori T, Balakrishna N. Anterior Segment Morphology in Primary Angle Closure Glaucoma

  20. Diagnostic Consistency and Relation Between Optical Coherence Tomography and Standard Automated Perimetry in Primary Open-Angle Glaucoma.

    PubMed

    Toprak, Ibrahim; Yaylalı, Volkan; Yildirim, Cem

    2017-01-01

    To assess diagnostic consistency and relation between spectral-domain optical coherence tomography (SD-OCT) and standard automated perimetry (SAP) in patients with primary open-angle glaucoma (POAG). This retrospective study comprised 51 eyes of 51 patients with a confirmed diagnosis of POAG. The qualitative and quantitative SD-OCT parameters (retinal nerve fiber layer thicknesses [RNFL; average, superior, inferior, nasal and temporal], RNFL symmetry, rim area, disc area, average and vertical cup/disc [C/D] ratio and cup volume) were compared with parameters of SAP (mean deviation, pattern standard deviation, visual field index, and glaucoma hemifield test reports). Fifty-one eyes of 51 patients with POAG were recruited. Twenty-nine eyes (56.9%) had consistent RNFL and visual field (VF) damage. However, nine patients (17.6%) showed isolated RNFL damage on SD-OCT and 13 patients (25.5%) had abnormal VF test with normal RNFL. In patients with VF defect, age, average C/D ratio, vertical C/D ratio, and cup volume were significantly higher and rim area was lower when compared to those of the patients with normal VF. In addition to these parameters, worsening in average, superior, inferior, and temporal RNFL thicknesses and RNFL symmetry was significantly associated with consistent SD-OCT and SAP outcomes. In routine practice, patients with POAG can be manifested with inconsistent reports between SD-OCT and SAP. An older age, higher C/D ratio, larger cup volume, and lower rim area on SD-OCT appears to be associated with detectable VF damage. Moreover, additional worsening in RNFL parameters might reinforce diagnostic consistency between SD-OCT and SAP.

  1. Differences between Non-arteritic Anterior Ischemic Optic Neuropathy and Open Angle Glaucoma with Altitudinal Visual Field Defect.

    PubMed

    Han, Sangyoun; Jung, Jong Jin; Kim, Ungsoo Samuel

    2015-12-01

    To investigate the differences in retinal nerve fiber layer (RNFL) change and optic nerve head parameters between non-arteritic anterior ischemic optic neuropathy (NAION) and open angle glaucoma (OAG) with altitudinal visual field defect. Seventeen NAION patients and 26 OAG patients were enrolled prospectively. The standard visual field indices (mean deviation, pattern standard deviation) were obtained from the Humphrey visual field test and differences between the two groups were analyzed. Cirrus HD-OCT parameters were used, including optic disc head analysis, average RNFL thickness, and RNFL thickness of each quadrant. The mean deviation and pattern standard deviation were not significantly different between the groups. In the affected eye, although the disc area was similar between the two groups (2.00 ± 0.32 and 1.99 ± 0.33 mm(2), p = 0.586), the rim area of the OAG group was smaller than that of the NAION group (1.26 ± 0.56 and 0.61 ± 0.15 mm(2), respectively, p < 0.001). RNFL asymmetry was not different between the two groups (p = 0.265), but the inferior RNFL thickness of both the affected and unaffected eyes were less in the OAG group than in the NAION group. In the analysis of optic disc morphology, both affected and unaffected eyes showed significant differences between two groups. To differentiate NAION from OAG in eyes with altitudinal visual field defects, optic disc head analysis of not only the affected eye, but also the unaffected eye, by using spectral domain optical coherence tomography may be helpful.

  2. Early full weight-bearing versus 6-week partial weight-bearing after open wedge high tibial osteotomy leads to earlier improvement of the clinical results: a prospective, randomised evaluation.

    PubMed

    Schröter, S; Ateschrang, A; Löwe, W; Nakayama, H; Stöckle, U; Ihle, C

    2017-01-01

    Open wedge high tibial osteotomy is a widespread treatment option in patients with varus malalignment and medial compartment osteoarthritis. There is no standardised protocol for post-operative rehabilitation available. The purpose of this study was to compare two post-operative rehabilitation protocols and to evaluate the clinical outcome of early full weight-bearing after open wedge HTO. One hundred and twenty consecutive patients with varus malalignment and medial compartment osteoarthritis received an open wedge HTO using an angular locking plate fixation between December 2008 and December 2011. All patients were assigned randomly into one of two groups with different post-operative rehabilitation protocols (11-day vs. 6-week 20-kg partial weight-bearing). Clinical outcome was evaluated using established instruments (Lequesne, Lysholm, HSS and IKDC scores) preoperatively, 6, 12 and 18 months post-operatively. Deformity analysis was performed preoperatively and during follow-up. All clinical scores showed a significant pre- to post-operative improvement. After 6 months, there was a higher improvement in the group of early full weight-bearing. The difference between preoperative and 6-month follow-up for the group with early full weight-bearing and for the group with 20-kg PWB for 6 weeks was 28 ± 26 and 18 ± 22, respectively, for the Lysholm score and -5.0 ± 5.1 and -3.0 ± 3.6, respectively, for the Lequesne score. Early full weight-bearing (11-day 20-kg partial weight-bearing) after open wedge HTO without bone graft leads to earlier improvement of the clinical results and can be recommended for post-operative rehabilitation after open wedge HTO and fixation with an angular locking plate. Therapeutic study, Level I.

  3. Angle stations in or for endless conveyor belts

    DOEpatents

    Steel, Alan

    1987-04-07

    In an angle station for an endless conveyor belt, there are presented to each incoming run of the belt stationary curved guide members (18, 19) of the shape of a major segment of a right-circular cylinder and having in the part-cylindrical portion (16 or 17) thereof rectangular openings (15) arranged in parallel and helical paths and through which project small freely-rotatable rollers (14), the continuously-changing segments of the curved surfaces of which projecting through said openings (15) are in attitude to change the direction of travel of the belt (13) through 90.degree. during passage of the belt about the part-cylindrical portion (16 or 17) of the guide member (18 or 19). The rectangular openings (15) are arranged with their longer edges lengthwise of the diagonals representing the mean of the helix but with those of a plurality of the rows nearest to each end of the part-cylindrical portion (16 or 17) slightly out of axial symmetry with said diagonals, being slightly inclined in a direction about the intersections (40) of the diagonals of the main portion of the openings, to provide a "toe-in" attitude in relation to the line of run of the endless conveyor belt.

  4. Relationship between iris surface features and angle width in Asian eyes.

    PubMed

    Sidhartha, Elizabeth; Nongpiur, Monisha Esther; Cheung, Carol Y; He, Mingguang; Wong, Tien Yin; Aung, Tin; Cheng, Ching-Yu

    2014-10-23

    To examine the associations between iris surface features with anterior chamber angle width in Asian eyes. In this prospective cross-sectional study, we recruited 600 subjects from a large population-based study, the Singapore Epidemiology of Eye Diseases (SEED) study. We obtained standardized digital slit-lamp iris photographs and graded the iris crypts (by number and size), furrows (by number and circumferential extent), and color (higher grade denoting darker iris). Vertical and horizontal cross-sections of anterior chamber were imaged using anterior segment optical coherence tomography. Angle opening distance (AOD), angle recess area (ARA), and trabecular-iris space area (TISA) were measured using customized software. Associations of the angle width with the iris surface features in the subject's right eyes were assessed using linear regression analysis. A total of 464 eyes of the 464 subjects (mean age: 57.5 ± 8.6 years) had complete and gradable data for crypts and color, and 423 eyes had gradable data for furrows. After adjustment for age, sex, ethnicity, pupil size, and corneal arcus, higher crypt grade was independently associated with wider AOD750 (β [change in angle width per grade higher] = 0.018, P = 0.023), ARA750 (β = 0.022, P = 0.049), and TISA750 (β = 0.011, P = 0.019), and darker iris was associated narrower ARA750 (β = -0.025, P = 0.044) and TISA750 (β = -0.013, P = 0.011). Iris surface features, assessed and measured from slit-lamp photographs, correlated well with anterior chamber angle width; irises with more crypts and lighter color were associated with wider angle. These findings may provide another imaging modality to assess angle closure risk based on iris surface features. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  5. Optimal reconstruction angles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, G.O. Jr.; Knight, L.

    1979-07-01

    The question of optimal projection angles has recently become of interest in the field of reconstruction from projections. Here, studies are concentrated on the n x n pixel space, where literative algorithms such as ART and direct matrix techniques due to Katz are considered. The best angles are determined in a Gauss--Markov statistical sense as well as with respect to a function-theoretical error bound. The possibility of making photon intensity a function of angle is also examined. Finally, the best angles to use in an ART-like algorithm are studied. A certain set of unequally spaced angles was found to bemore » preferred in several contexts. 15 figures, 6 tables.« less

  6. Early Experiences Writing Performance Portable OpenMP 4 Codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joubert, Wayne; Hernandez, Oscar R

    In this paper, we evaluate the recently available directives in OpenMP 4 to parallelize a computational kernel using both the traditional shared memory approach and the newer accelerator targeting capabilities. In addition, we explore various transformations that attempt to increase application performance portability, and examine the expressiveness and performance implications of using these approaches. For example, we want to understand if the target map directives in OpenMP 4 improve data locality when mapped to a shared memory system, as opposed to the traditional first touch policy approach in traditional OpenMP. To that end, we use recent Cray and Intel compilersmore » to measure the performance variations of a simple application kernel when executed on the OLCF s Titan supercomputer with NVIDIA GPUs and the Beacon system with Intel Xeon Phi accelerators attached. To better understand these trade-offs, we compare our results from traditional OpenMP shared memory implementations to the newer accelerator programming model when it is used to target both the CPU and an attached heterogeneous device. We believe the results and lessons learned as presented in this paper will be useful to the larger user community by providing guidelines that can assist programmers in the development of performance portable code.« less

  7. Novel Automated Approach to Predict the Outcome of Laser Peripheral Iridotomy for Primary Angle Closure Suspect Eyes Using Anterior Segment Optical Coherence Tomography.

    PubMed

    Koh, Victor; Swamidoss, Issac Niwas; Aquino, Maria Cecilia D; Chew, Paul T; Sng, Chelvin

    2018-04-27

    Develop an algorithm to predict the success of laser peripheral iridotomy (LPI) in primary angle closure suspect (PACS), using pre-treatment anterior segment optical coherence tomography (ASOCT) scans. A total of 116 eyes with PACS underwent LPI and time-domain ASOCT scans (temporal and nasal cuts) were performed before and 1 month after LPI. All the post-treatment scans were classified to one of the following categories: (a) both angles open, (b) one of two angles open and (c) both angles closed. After LPI, success is defined as one or more angles changed from close to open. In this proposed method, the pre and post-LPI ASOCT scans were registered at the corresponding angles based on similarities between the respective local descriptor features and random sample consensus technique was used to identify the largest consensus set of correspondences between the pre and post-LPI ASOCT scans. Subsequently, features such as correlation co-efficient (CC) and structural similarity index (SSIM) were extracted and correlated with the success of LPI. We included 116 eyes and 91 (78.44%) eyes fulfilled the criteria for success after LPI. Using the CC and SSIM index scores from this training set of ASOCT images, our algorithm showed that the success of LPI in eyes with narrow angles can be predicted with 89.7% accuracy, specificity of 95.2% and sensitivity of 36.4% based on pre-LPI ASOCT scans only. Using pre-LPI ASOCT scans, our proposed algorithm showed good accuracy in predicting the success of LPI for PACS eyes. This fully-automated algorithm could aid decision making in offering LPI as a prophylactic treatment for PACS.

  8. Comparison of Factors Associated With Occludable Angle Between American Caucasians and Ethnic Chinese

    PubMed Central

    Wang, Ye Elaine; Li, Yingjie; Wang, Dandan; He, Mingguang; Lin, Shan

    2013-01-01

    Purpose. To determine if factors associated with gonioscopy-determined occludable angle among American Caucasians are similar to those found in ethnic Chinese. Methods. This is a prospective cross-sectional study with 120 American Caucasian, 116 American Chinese, and 116 mainland Chinese subjects. All three groups were matched for sex and age (40–80 years). Gonioscopy was performed for each subject (occludable angles = posterior trabecular meshwork not visible for ≥2 quadrants). Anterior segment optical coherence tomography and customized software was used to measure anterior segment biometry and iris parameters, including anterior chamber depth/width (ACD, ACW), lens vault (LV), and iris thickness/area/curvature. Results. In both Chinese and Caucasians, eyes with occludable angles had smaller ACD and ACW, and larger LV and iris curvature than eyes with open angles (all P < 0.005). Chinese eyes had smaller ACD and ACW than Caucasian eyes (both P < 0.01) in the occludable angle cohort. Iris characteristics did not differ significantly between Chinese and Caucasians in the occludable angle cohort. Based on multivariate logistic regression, gonioscopy-determined occludable angle was significantly associated with LV, iris area, and sex (all P < 0.03) in Chinese; and with LV, ACD, iris thickness, age, and sex (all P < 0.04) in Caucasians. Conclusions. Several factors associated with occludable angle differed between Caucasians and Chinese, suggesting potentially different mechanisms in occludable angle development in the two racial groups. This is the first study to demonstrate that lens vault is an important anterior segment optical coherence tomography parameter in the screening for angle closure in Caucasians. In addition, iris thickness was a significant predictor for occludable angles in Caucasians but was not in ethnic Chinese. PMID:24168992

  9. {l_angle}110{r_angle} dendrite growth in aluminum feathery grains

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henry, S.; Rappaz, M.; Jarry, P.

    1998-11-01

    Automatic indexing of electron backscattered diffraction patterns, scanning electron microscopy, and optical microscopy observations have been carried out on aluminum-magnesium-silicon, aluminum-copper, and aluminum-silicon alloys directionally solidified or semicontinuously cast using the direct chill casting process. From these combined observations, it is shown that the feathery grains are made of {l_angle}110{r_angle} primary dendrite trunks (e.g., [011{bar 1}]) split in their centers by a coherent (111) twin plane. The average spacing of the dendrite trunks in the twin plane (about 10 to 20 {micro}m) is typically one order of magnitude smaller than that separating successive rows of trunks (or twin planes). Themore » [011{bar 1}] orientation of these trunks is close to the thermal gradient direction (typically within 15 deg)--a feature probably resulting from a growth competition mechanism similar to that occurring during normal <100> columnar dendrite growth. On both sides of these trunks, secondary dendrite arms also grow along {l_angle}110{r_angle} directions. Their impingement creates wavy noncoherent twin boundaries between the coherent twin planes. In the twin plane, evidence is shown that {l_angle}110{r_angle} branching mechanisms lead to the propagation of the twinned regions, to the regular arrangement of the primary dendrite trunks along a [{bar 2}11] direction, and to coherent planar twin boundaries. From these observations, it is concluded that the feathery grains are probably the result of a change from a normal <100> to a {l_angle}110{r_angle} surface tension/attachment kinetics anisotropy growth mode. Finally, the proposed mechanisms of leathery grain growth are further supported by the observation of {l_angle}110{r_angle} dendrite growth morphologies in thin aluminum-zinc coatings.« less

  10. Signature of non-isotropic distribution of stellar rotation inclination angles in the Praesepe cluster

    NASA Astrophysics Data System (ADS)

    Kovacs, Geza

    2018-04-01

    The distribution of the stellar rotation axes of 113 main sequence stars in the open cluster Praesepe are examined by using current photometric rotation periods, spectroscopic rotation velocities, and estimated stellar radii. Three different samples of stellar rotation data on spotted stars from the Galactic field and two independent samples of planetary hosts are used as control samples to support the consistency of the analysis. Considering the high completeness of the Praesepe sample and the behavior of the control samples, we find that the main sequence F - K stars in this cluster are susceptible to rotational axis alignment. Using a cone model, the most likely inclination angle is 76° ± 14° with a half opening angle of 47° ± 24°. Non-isotropic distribution of the inclination angles is preferred over the isotropic distribution, except if the rotation velocities used in this work are systematically overestimated. We found no indication of this being the case on the basis of the currently available data. Data are only available at the CDS, together with the other two compiled datasets used in this paper, via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/612/L2

  11. A study comparing ultrasound images of tongue movements between open bite children and normal children in the early mixed dentition period.

    PubMed

    Kikyo, T; Saito, M; Ishikawa, M

    1999-09-01

    The tongue surface movement of young patients with or without open bite was evaluated by ultrasound images taken on the posterior part of the tongue on the frontal plane to determine whether there is any relationship between the tongue movement and open bite malocclusion in the early mixed dentition period. The standardized reproducible ultrasound images were obtained using ultrasound diagnostic equipment that was fabricated in a cephalostat unit having a probe stabilizer. At the central portion of the tongue, no significant differences were detected in the duration or the momentum of tongue surface movement on a frontal plane was detected between the patients with and without open bite during swallowing. The farther the region was from the central portion, however, the longer the duration and the bigger the momentum of the tongue surface movement was found in the open bite group. Based on this evidence, it is suggested that an open-bite child swallows by using a tongue thrust motion that forms using a large depressed area in the tongue, whereas a normal child without tongue thrust forms a rather narrow groove in the central portion of the tongue when swallowing.

  12. The Research of the Parallel Computing Development from the Angle of Cloud Computing

    NASA Astrophysics Data System (ADS)

    Peng, Zhensheng; Gong, Qingge; Duan, Yanyu; Wang, Yun

    2017-10-01

    Cloud computing is the development of parallel computing, distributed computing and grid computing. The development of cloud computing makes parallel computing come into people’s lives. Firstly, this paper expounds the concept of cloud computing and introduces two several traditional parallel programming model. Secondly, it analyzes and studies the principles, advantages and disadvantages of OpenMP, MPI and Map Reduce respectively. Finally, it takes MPI, OpenMP models compared to Map Reduce from the angle of cloud computing. The results of this paper are intended to provide a reference for the development of parallel computing.

  13. Awareness of incident open-angle glaucoma in a population study: the Barbados Eye Studies.

    PubMed

    Hennis, Anselm; Wu, Suh-Yuh; Nemesure, Barbara; Honkanen, Robert; Leske, M Cristina

    2007-10-01

    To evaluate factors related to awareness of incident open-angle glaucoma (OAG) in the Barbados Eye Studies. Cohort study with 81% to 85% response rate over 9 years. Four thousand three hundred fourteen participants of African descent, 40 to 84 years old at baseline. Standardized study visits included an interview on demographic, medical, health care, and other factors; various ophthalmic measurements; fundus photography; and comprehensive ophthalmologic examinations for those referred. Definite OAG was defined by both visual field and optic disc criteria after ophthalmologic confirmation, regardless of intraocular pressure (IOP). Definite incident participants without prior OAG diagnosis/treatment were considered unaware. Logistic regression analyses evaluated factors associated with OAG unawareness. Results were expressed as odds ratios (ORs) with 95% confidence intervals (CIs). Over 9 years, 125 participants newly developed definite OAG, of whom 53% were previously unaware. At baseline, the unaware group had significantly lower mean IOP (OR, 0.86; 95% CI, 0.79-0.94) and more hyperopia (OR, 2.69; 95% CI, 1.08-6.69) than those aware. Most unaware and aware participants had > or =2 medical care visits in the previous year (72.7% vs. 83.1%). However, those in the unaware group sought eye care less frequently than those aware (last visit in preceding year, 33.4% vs. 64.4%); these visits were mainly for eyeglasses (71.4% vs. 12.5%), with most having glaucoma tests only during study visits (72.7% vs. 37.3%). The unaware group reported more visits to opticians/optometrists than to private ophthalmologists (OR, 4.20; 95% CI, 1.00-17.66) and fewer visits to a public ophthalmologic clinic (OR, 0.18; 95% CI, 0.04-0.86). Over half of participants with incident OAG were unaware of their diagnosis. Unawareness was related to lower IOP, hyperopia, and eye care utilization patterns. Although persons in the unaware group had regular visits for medical care, visits for eye care and

  14. Hydraulic droplet coarsening in open-channel capillaries

    NASA Astrophysics Data System (ADS)

    Warren, Patrick B.

    2016-11-01

    Over a range of liquid-solid contact angles, an open-channel capillary with curved or angled sides can show a maximum in the Laplace pressure as a function of the filling state. Examples include double-angle wedges, grooves scored into flat surfaces, steps on surfaces, and the groove between touching parallel cylinders. The liquid in such a channel exhibits a beading instability if the channel is filled beyond the Laplace pressure maximum. The subsequent droplet coarsening takes place by hydraulic transport through the connecting liquid columns that remain in the groove. A mean-field scaling argument predicts the characteristic droplet radius R ˜t1 /7 , as a function of time t . This is confirmed by one-dimensional simulations of the coarsening kinetics. Some remarks are also made on the spreading kinetics of an isolated drop deposited in such a channel.

  15. Linkage analysis of primary open-angle glaucoma excludes the juvenile glaucoma region on chromosome 1q

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wirtz, M.K.; Acott, T.S.; Samples, J.R.

    1994-09-01

    The gene for one form of juvenile glaucoma has been mapped to chromosome 1q21-q31. This raises the possibility of primary open-angle glaucoma (POAG) also mapping to this region if the same defective gene causes both diseases. To ask this question linkage analysis was performed on a large POAG kindred. Blood samples or skin biopsies were obtained from 40 members of this family. Individuals were diagnosed as having POAG if they met two or more of the following criteria: (1) Visual field defects compatible with glaucoma on automated perimetry; (2) Optic nerve head and/or nerve fiber layer analysis compatible with glaucomatousmore » damage; (3) high intraocular pressures (> 20 mm Hg). Patients were considered glaucoma suspects if they only met one criterion. These individuals were excluded from the analysis. Of the 40 members, seven were diagnosed with POAG; four were termed suspects. The earliest age of onset was 38 years old, while the average age of onset was 65 years old. We performed two-point and multipoint linkage analysis, using five markers which encompass the region 1q21-q31; specifically, D1S194, D1S210, D1S212, D1S191 and LAMB2. Two-point lod scores excluded tight linkage with all markers except D1S212 (maximum lod score of 1.07 at theta = 0.0). In the multipoint analysis, including D1S210-D1S212-LAMB2 and POAG, the entire 11 cM region spanned by these markers was excluded for linkage with POAG; that is, lod scores were < -2.0. In conclusion, POAG in this family does not map to chromosome 1q21-q31 and, thus, they carry a gene that is distinct from the juvenile glaucoma gene.« less

  16. A Pilot Study to Evaluate the Oral Microbiome and Dental Health in Primary Open-Angle Glaucoma.

    PubMed

    Polla, Daniel; Astafurov, Konstantin; Hawy, Eman; Hyman, Leslie; Hou, Wei; Danias, John

    2017-04-01

    To evaluate possible associations between primary open-angle glaucoma (POAG), dental health, and the oral microbiome. Case-control study was conducted at SUNY Downstate. Adult subjects (40 to 87 y) were recruited as POAG cases (n=119) and controls without glaucoma (n=78) based on visual field and optic nerve criteria. Overall 74.6% were African Americans (AA). Information on medical history and oral health was collected and ophthalmologic examinations were performed. Mouthwash specimens (28 AA cases and 17 controls) were analyzed for bacterial DNA amounts. Analyses were limited to AAs as the predominant racial group. Outcome measures included number of natural teeth, self-reported periodontal health parameters, and amounts and prevalence of oral bacterial species. Logistic regression was used to evaluate associated factors and potential interactions. Cases and controls had similar age (mean: 62.2 and 60.9 y, respectively, P>0.48), and frequency of hypertension, diabetes, but cases had a higher proportion of men (P<0.04). On average (±SD), cases had fewer natural teeth than controls [18.0 (±11.1) vs. 20.7 (±9.4)]. Having more natural teeth was inversely associated with POAG, in multivariable analyses, at older ages [eg, odds ratio (95% confidence interval) at age 55: 1.0 (0.95-1.06), P=0.98 vs. at age 85: 0.87 (0.79-0.96), P=0.007]. Amounts of Streptococci were higher in cases than controls (P<0.03) in samples from the subset of subjects analyzed. The number of teeth (an oral health indicator) and alterations in the amounts of oral bacteria may be associated with glaucoma pathology. Further investigation of the association between dental health and glaucoma is warranted.

  17. Steroid-induced glaucoma treated with trabecular ablation in a matched comparison with primary open-angle glaucoma.

    PubMed

    Dang, Yalong; Kaplowitz, Kevin; Parikh, Hardik A; Roy, Pritha; Loewen, Ralitsa T; Francis, Brian A; Loewen, Nils A

    2016-12-01

    To evaluate the outcomes of trabectome-mediated ab interno trabeculectomy in patients with steroid-induced glaucoma (SIG). A retrospective, observational cohort study performed in the Department of Ophthalmology, University of Pittsburgh Medical Center. The data of 60 patients with SIG and 484 controls with primary open-angle glaucoma (POAG) matched by age, gender and glaucoma index were collected from the Trabectome Study Group database. Reduction of intraocular pressure (IOP) and medications were compared between POAG and SIG by multivariate regression. Kaplan-Meier was used for survival analysis. Success was defined as IOP ≤21 mmHg and at least 20% IOP reduction from baseline for any two consecutive visits after 3 months without secondary glaucoma surgery. Postoperative IOP and number of medications were compared with baseline in the SIG subgroups by the Wilcoxon test. Intraocular pressure reduction and 1-year success rate. Patients with SIG had a higher baseline IOP (31.4 ± 10.4 vs. 24.1 ± 7.6 mmHg, P < 0.01) and obtained a greater IOP reduction than controls with POAG (48.4% vs. 31.5%, P < 0.01). Multivariate regression showed that patients with SIG had an IOP reduction of 6.7 ± 1.1 mmHg more than those with POAG. Survival rates at 12 months were comparable at 86% in the SIG group and 85% in the POAG group (P = 0.47). Patients with SIG with a high baseline IOP, younger age and advanced glaucoma experienced a larger IOP drop. Trabectome appears to be an effective surgical treatment in reducing IOP for patients with SIG. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  18. Genetic correlations between intraocular pressure, blood pressure and primary open-angle glaucoma: a multi-cohort analysis.

    PubMed

    Aschard, Hugues; Kang, Jae H; Iglesias, Adriana I; Hysi, Pirro; Cooke Bailey, Jessica N; Khawaja, Anthony P; Allingham, R Rand; Ashley-Koch, Allison; Lee, Richard K; Moroi, Sayoko E; Brilliant, Murray H; Wollstein, Gadi; Schuman, Joel S; Fingert, John H; Budenz, Donald L; Realini, Tony; Gaasterland, Terry; Scott, William K; Singh, Kuldev; Sit, Arthur J; Igo, Robert P; Song, Yeunjoo E; Hark, Lisa; Ritch, Robert; Rhee, Douglas J; Gulati, Vikas; Haven, Shane; Vollrath, Douglas; Zack, Donald J; Medeiros, Felipe; Weinreb, Robert N; Cheng, Ching-Yu; Chasman, Daniel I; Christen, William G; Pericak-Vance, Margaret A; Liu, Yutao; Kraft, Peter; Richards, Julia E; Rosner, Bernard A; Hauser, Michael A; Klaver, Caroline C W; vanDuijn, Cornelia M; Haines, Jonathan; Wiggs, Janey L; Pasquale, Louis R

    2017-11-01

    Primary open-angle glaucoma (POAG) is the most common chronic optic neuropathy worldwide. Epidemiological studies show a robust positive relation between intraocular pressure (IOP) and POAG and modest positive association between IOP and blood pressure (BP), while the relation between BP and POAG is controversial. The International Glaucoma Genetics Consortium (n=27 558), the International Consortium on Blood Pressure (n=69 395), and the National Eye Institute Glaucoma Human Genetics Collaboration Heritable Overall Operational Database (n=37 333), represent genome-wide data sets for IOP, BP traits and POAG, respectively. We formed genome-wide significant variant panels for IOP and diastolic BP and found a strong relation with POAG (odds ratio and 95% confidence interval: 1.18 (1.14-1.21), P=1.8 × 10 -27 ) for the former trait but no association for the latter (P=0.93). Next, we used linkage disequilibrium (LD) score regression, to provide genome-wide estimates of correlation between traits without the need for additional phenotyping. We also compared our genome-wide estimate of heritability between IOP and BP to an estimate based solely on direct measures of these traits in the Erasmus Rucphen Family (ERF; n=2519) study using Sequential Oligogenic Linkage Analysis Routines (SOLAR). LD score regression revealed high genetic correlation between IOP and POAG (48.5%, P=2.1 × 10 -5 ); however, genetic correlation between IOP and diastolic BP (P=0.86) and between diastolic BP and POAG (P=0.42) were negligible. Using SOLAR in the ERF study, we confirmed the minimal heritability between IOP and diastolic BP (P=0.63). Overall, IOP shares genetic basis with POAG, whereas BP has limited shared genetic correlation with IOP or POAG.

  19. The Critical Angle Can Override the Brewster Angle

    ERIC Educational Resources Information Center

    Froehle, Peter H.

    2009-01-01

    As a culminating activity in their study of optics, my students investigate polarized light and the Brewster angle. In this exercise they encounter a situation in which it is impossible to measure the Brewster angle for light reflecting from a particular surface. This paper describes the activity and explains the students' observations.

  20. Influence of surgical implantation angle of left ventricular assist device outflow graft and management of aortic valve opening on the risk of stroke in heart failure patients

    NASA Astrophysics Data System (ADS)

    Chivukula, V. Keshav; McGah, Patrick; Prisco, Anthony; Beckman, Jennifer; Mokadam, Nanush; Mahr, Claudius; Aliseda, Alberto

    2016-11-01

    Flow in the aortic vasculature may impact stroke risk in patients with left ventricular assist devices (LVAD) due to severely altered hemodynamics. Patient-specific 3D models of the aortic arch and great vessels were created with an LVAD outflow graft at 45, 60 and 90° from centerline of the ascending aorta, in order to understand the effect of surgical placement on hemodynamics and thrombotic risk. Intermittent aortic valve opening (once every five cardiac cycles) was simulated and the impact of this residual native output investigated for the potential to wash out stagnant flow in the aortic root region. Unsteady CFD simulations with patient-specific boundary conditions were performed. Particle tracking for 10 cardiac cycles was used to determine platelet residence times and shear stress histories. Thrombosis risk was assessed by a combination of Eulerian and Lagrangian metrics and a newly developed thrombogenic potential metric. Results show a strong influence of LVAD outflow graft angle on hemodynamics in the ascending aorta and consequently on stroke risk, with a highly positive impact of aortic valve opening, even at low frequencies. Optimization of LVAD implantation and management strategies based on patient-specific simulations to minimize stroke risk will be presented

  1. Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: A systematic review and meta-analysis.

    PubMed

    Lavia, Carlo; Dallorto, Laura; Maule, Milena; Ceccarelli, Manuela; Fea, Antonio Maria

    2017-01-01

    MIGS have been developed as a surgical alternative for glaucomatous patients. To analyze the change in intraocular pressure (IOP) and glaucoma medications using different MIGS devices (Trabectome, iStent, Excimer Laser Trabeculotomy (ELT), iStent Supra, CyPass, XEN, Hydrus, Fugo Blade, Ab interno canaloplasty, Goniscopy-assisted transluminal trabeculotomy) as a solo procedure or in association with phacoemulsification. Randomized control trials (RCT) and non-RCT (non randomized comparative studies, NRS, and before-after studies) were included. Studies with at least one year of follow-up in patients affected by primary open angle glaucoma, pseudoexfoliative glaucoma or pigmentary glaucoma were considered. Risk of Bias assessment was performed using the Cochrane Risk of Bias and the ROBINS-I tools. The main outcome was the effect of MIGS devices compared to medical therapy, cataract surgery, other glaucoma surgeries and other MIGS on both IOP and use of glaucoma medications 12 months after surgery. Outcomes measures were the mean difference in the change of IOP and glaucoma medication compared to baseline at one and two years and all ocular adverse events. The current meta-analysis is registered on PROSPERO (reference n° CRD42016037280). Over a total of 3,069 studies, nine RCT and 21 case series with a total of 2.928 eyes were included. Main concerns about risk of bias in RCTs were lack of blinding, allocation concealment and attrition bias while in non-RCTs they were represented by patients' selection, masking of participants and co-intervention management. Limited evidence was found based on both RCTs and non RCTs that compared MIGS surgery with medical therapy or other MIGS. In before-after series, MIGS surgery seemed effective in lowering both IOP and glaucoma drug use. MIGS showed a good safety profile: IOP spikes were the most frequent complications and no cases of infection or BCVA loss due to glaucoma were reported. Although MIGS seem efficient in the

  2. Comparison of diagnostic capability of macular ganglion cell complex and retinal nerve fiber layer among primary open angle glaucoma, ocular hypertension, and normal population using Fourier-domain optical coherence tomography and determining their functional correlation in Indian population

    PubMed Central

    Barua, Nabanita; Sitaraman, Chitra; Goel, Sonu; Chakraborti, Chandana; Mukherjee, Sonai; Parashar, Hemandra

    2016-01-01

    Context: Analysis of diagnostic ability of macular ganglionic cell complex and retinal nerve fiber layer (RNFL) in glaucoma. Aim: To correlate functional and structural parameters and comparing predictive value of each of the structural parameters using Fourier-domain (FD) optical coherence tomography (OCT) among primary open angle glaucoma (POAG) and ocular hypertension (OHT) versus normal population. Setting and Design: Single centric, cross-sectional study done in 234 eyes. Materials and Methods: Patients were enrolled in three groups: POAG, ocular hypertensive and normal (40 patients in each group). After comprehensive ophthalmological examination, patients underwent standard automated perimetry and FD-OCT scan in optic nerve head and ganglion cell mode. The relationship was assessed by correlating ganglion cell complex (GCC) parameters with mean deviation. Results were compared with RNFL parameters. Statistical Analysis: Data were analyzed with SPSS, analysis of variance, t-test, Pearson's coefficient, and receiver operating curve. Results: All parameters showed strong correlation with visual field (P < 0.001). Inferior GCC had highest area under curve (AUC) for detecting glaucoma (0.827) in POAG from normal population. However, the difference was not statistically significant (P > 0.5) when compared with other parameters. None of the parameters showed significant diagnostic capability to detect OHT from normal population. In diagnosing early glaucoma from OHT and normal population, only inferior GCC had statistically significant AUC value (0.715). Conclusion: In this study, GCC and RNFL parameters showed equal predictive capability in perimetric versus normal group. In early stage, inferior GCC was the best parameter. In OHT population, single day cross-sectional imaging was not valuable. PMID:27221682

  3. Anterior segment optical coherence tomography parameters in phacomorphic angle closure and mature cataracts.

    PubMed

    Mansouri, Mohammadreza; Ramezani, Farshid; Moghimi, Sasan; Tabatabaie, Ali; Abdi, Fatemeh; He, Mingguang; Lin, Shan C

    2014-10-21

    To describe anterior segment optical coherence tomography (AS-OCT) parameters in phacomorphic angle closure eyes, mature cataract eyes, and their fellow eyes, and identify those parameters that could be used to differentiate phacomorphic angle closure eyes from those with mature cataract and no phacomorphic angle closure. In this cross-sectional study, a total of 33 phacomorphic angle closure subjects and 34 control patients with unilateral mature cataracts were enrolled. All patients underwent AS-OCT imaging and A-scan biometry of both eyes. Anterior chamber depth (ACD), anterior chamber area (ACA), iris thickness, iris curvature, lens vault (LV), and angle parameters, including angle opening distance (AOD750) and trabecular-iris space area (TISA750), were measured in qualified images using customized software and compared among eyes with phacomorphic angle closure, mature cataract eyes, and their fellow eyes. There was no significant difference in axial length among the four groups. Phacomorphic angle closure had the smallest angle (AOD750, TISA750) and anterior chamber parameters (ACD, ACA, anterior chamber width) and the greatest LV among the groups. This pattern was similar when comparing fellow eyes of mature cataract patients and fellow eyes of phacomorphic angle closure. Anterior chamber area less than 18.62 mm(2), ACD less than 2.60 mm, LV greater than 532.0 μm, and AOD750 less than 0.218 mm had the highest odds ratios (ORs) for distinguishing fellow eyes of phacomorphic angle closure versus fellow eyes of mature cataracts, with OR values of 9.90, 8.31, 7.91, and 7.91, respectively. Logistic regression showed that ACA less than 18.62 was the major parameter associated with fellow eyes of phacomorphic angle closure (OR = 10.96, P < 0.001). Anterior chamber depth, ACA, AOD750, and LV are powerful indicators in differentiating phacomorphic angle closure eyes from those with mature cataract and their fellow eyes. Copyright 2014 The Association for Research in

  4. Pilot Study of the Effects of Ambient Light Level Variation on Spectral Domain Anterior Segment OCT-Derived Angle Metrics in Caucasians versus Asians.

    PubMed

    Dastiridou, Anna; Marion, Kenneth; Niemeyer, Moritz; Francis, Brian; Sadda, Srinivas; Chopra, Vikas

    2018-04-11

    To investigate the effects of ambient light level variation on spectral domain anterior segment optical coherence tomography (SD-ΟCT)-derived anterior chamber angle metrics in Caucasians versus Asians. Caucasian (n = 24) and Asian participants of Chinese ancestry (n = 24) with open angles on gonioscopy had one eye imaged twice at five strictly controlled, ambient light levels. Ethnicity was self-reported. Light levels were strictly controlled using a light meter at 1.0, 0.75, 0.5, 0.25, and 0 foot candle illumination levels. SD-OCT 5-line raster scans at the inferior 270° irido-corneal angle were measured by two trained, masked graders from the Doheny Image Reading Center using customized Image-J software. Schwalbe's line-angle opening distance (SL-AOD) and SL-trabecular iris space area (SL-TISA) in different light meter readings (LMRs) between the two groups were compared. Baseline light SL-AOD and SL-TISA measured 0.464 ± 0.115mm/0.351 ± 0.110mm 2 and 0.344 ± 0.118mm/0.257 ± 0.092mm 2 , respectively, in the Caucasian and the Asian group. SL-AOD and SL-TISA in each LMR were significantly larger in the Caucasian group compared to the Asian group (p < 0.05). Despite this difference in angle size between the groups, there were no statistically significant differences in the degree of change in angle parameters from light to dark (% changes in SL-AOD or SL-TISA between the two groups were statistically similar with all p-values >0.3). SL-based angle dimensions using SD-OCT are sensitive to changes in ambient illumination in participants with Caucasian and Asian ancestry. Although Caucasian eyes had larger baseline angle opening under bright light conditions, the light-to-dark change in angle dimensions was similar in the two groups.

  5. [Correlation of intraocular pressure variation after visual field examination with 24-hour intraocular pressure variations in primary open-angle glaucoma].

    PubMed

    Noro, Takahiko; Nakamoto, Kenji; Sato, Makoto; Yasuda, Noriko; Ito, Yoshinori; Ogawa, Shumpei; Nakano, Tadashi; Tsuneoka, Hiroshi

    2014-10-01

    We retrospectively examined intraocular pressure variations after visual field examination in primary open angle glaucoma (POAG), together with its influencing factors and its association with 24-hour intraocular pressure variations. Subjects were 94 eyes (52 POAG patients) subjected to measurements of 24-hour intraocular pressure and of changes in intraocular pressure after visual field examination using a Humphrey Visual Field Analyzer. Subjects were classified into three groups according to the magnitude of variation (large, intermediate and small), and 24-hour intraocular pressure variations were compared among the three groups. Factors influencing intraocular pressure variations after visual field examination and those associated with the large variation group were investigated. Average intraocular pressure variation after visual field examination was -0.28 ± 1.90 (range - 6.0(-) + 5.0) mmHg. No significant influencing factors were identified. The intraocular pressure at 3 a.m. was significantly higher in the large variation group than other two groups (p < 0.001). Central corneal thickness was correlated with the large variation group (odds ratio = 1.04; 95% confidence interval, 1.01-1.07 ; p = 0.02). No particular tendencies in intraocular pressure variations were found after visual field examination. Increases in intraocular pressure during the night might be associated with large intraocular pressure variations after visual field examination.

  6. Vegetation in group-selection openings: early trends

    Treesearch

    Philip M. McDonald; Paula J. Anderson; Gary O. Fiddler

    1997-01-01

    Nine openings that ranged from 0.2 to 1.6 acres and were grouped into small, medium, and large size classes comprised the initial group-selection cut on the Boggs Mountain State Forest in north central California. Five growing seasons after site preparation by pile and burn, 81 plant species in 35 families were present. Forbs, ferns, graminoids, manzanita, other shrubs...

  7. [effectiveness of open reduction and internal fixation without opening joint capsule on tibial plateau fracture].

    PubMed

    Chen, Qi; Xu, Xiaofeng; Huang, Yonghui; Cao, Xingbing; Meng, Chen; Cao, Xueshu; Wei, Changbao

    2014-12-01

    To introduce the surgery method to reset and fix tibial plateau fracture without opening joint capsule, and evaluate the safety and effectiveness of this method. Between July 2011 and July 2013, 51 patients with tibial plateau fracture accorded with the inclusion criteria were included. All of 51 patients, 17 cases underwent open reduction and internal fixation without opening joint capsule in trial group, and 34 cases underwent traditional surgery method in control group. There was no significant difference in gender, age, cause of injury, time from injury to admission, side of injury, and types of fracture between 2 groups (P > 0.05). The operation time, intraoperative blood loss, incision length, incision healing, and fracture healing were compared between 2 groups. The tibial-femoral angle and collapse of joint surface were measured on X-ray film. At last follow-up, joint function was evaluated with Hospital for Special Surgery (HSS) knee function scale. The intraoperative blood loss in trial group was significantly less than that in control group (P < 0.05). The incision length in trial group was significantly shorter than that in control group (P < 0.05). Difference was not significant in operation time and the rate of incision healing between 2 groups (P > 0.05). The patients were followed up 12-30 months (mean, 20.4 months) in trial group and 12-31 months (mean, 18.2 months) in control group. X-ray films indicated that all cases in 2 groups obtained fracture healing; there was no significant difference in the fracture healing time between 2 groups (t=1.382, P=0.173). On X-ray films, difference was not significant in tibial-femoral angle and collapse of joint surface between 2 groups (P > 0.05). HSS score of the knee in trial group was significantly higher than that of control group (t=3.161, P=0.003). It can reduce the intraoperative blood loss and shorten the incision length to use open reduction and internal fixation without opening joint capsule for

  8. A brittle-ductile high- and low-angle fault related to the Kea extensional detachment (W Cyclades., Greece)

    NASA Astrophysics Data System (ADS)

    Rockenschaub, M.; Grasemann, B.; Iglseder, C.; Rice, A. H. N.; Schneider, D.; Zamolyi, A.

    2010-05-01

    Roll-back of the African Plate within the Eurasian-African collision zone since the Oligocene/Miocene led to extension in the Cyclades along low-angle normal fault zones and exhumation of rocks from near the brittle-ductile transition zone. On the island of Kea (W Cyclades), which represents such a crustal scale low-angle fault zone with top-to-SSW kinematics, remote sensing analysis of brittle fault lineaments in the Pissis area (W Kea) demonstrates two dominant strike directions: ca. NE-SW and NW-SE. From the north of Pisses southwards, the angle between the two main fault directions changes gradually from a rhombohedral geometry (ca. 50°/130° angle between faults, with the acute angle facing westwards) to an orthogonal geometry. The aim of this study is the development of this fault system. We investigate, if this fault system is related to the Miocene extension or if it is related to a later overprinting event (e.g. the opening of the Corinth) Field observations revealed that the investigated lineaments are high-angle (50-90° dip) brittle/ductile conjugate, faults. Due to the lack of marker layers offsets could only rarely be estimated. Locally centimetre thick marble layers in the greenschists suggest a displacement gradient along the faults with a maximum offset of less than 60 cm. Large displacement gradients are associated with a pronounced ductile fault drag in the host rocks. In some instances, high-angle normal faults were observed to link kinematically with low-angle, top-to-SSW brittle/ductile shear bands. Both the high- and the low-angle faults have a component of ductile shear, which is overprinted by brittle deformation mechanisms. In thin-section, polyphase mode-2 cracks are filled mainly with calcite and quartz (ultra)cataclasites, sometimes followed by further opening with fluid-related iron-rich carbonate (ankeritic) precipitation. CL analysis reveals several generations of cements, indicating multiple phases of cataclastic deformation and

  9. Short GRBs: Opening Angles, Local Neutron Star Merger Rate, and Off-axis Events for GRB/GW Association

    NASA Astrophysics Data System (ADS)

    Jin, Zhi-Ping; Li, Xiang; Wang, Hao; Wang, Yuan-Zhu; He, Hao-Ning; Yuan, Qiang; Zhang, Fu-Wen; Zou, Yuan-Chuan; Fan, Yi-Zhong; Wei, Da-Ming

    2018-04-01

    The jet breaks in the afterglow light curves of short gamma-ray bursts (SGRBs), rarely detected so far, are crucial for estimating the half-opening angles of the ejecta (θ j) and hence the neutron star merger rate. In this work, we report the detection of jet decline behaviors in GRB 150424A and GRB 160821B, and find θ j ∼ 0.1 rad. Together with five events reported before 2015 and three others “identified” recently (GRB 050709, GRB 060614, and GRB 140903A), we have a sample consisting of nine SGRBs and one long-short GRB with reasonably estimated θ j. In particular, three Swift bursts in the sample have redshifts z ≤ 0.2, with which we estimate the local neutron star merger rate density to be ∼ {1109}-657+1432 {Gpc}}-3 {yr}}-1 or {162}-83+140 {Gpc}}-3 {yr}}-1 if the narrowly beamed GRB 061201 is excluded. Inspired by the typical θ j ∼ 0.1 rad found currently, we further investigate whether the off-beam GRBs (in the uniform jet model) or the off-axis events (in the structured jet model) can significantly enhance the GRB/GW association. For the former, the enhancement is at most moderate, while for the latter the enhancement can be much greater and a high GRB/GW association probability of ∼10% is possible. We also show that the data of GRB 160821B may contain a macronova/kilonova emission component with a temperature of ∼3100 K at ∼3.6 days after the burst and more data are needed to ultimately clarify.

  10. Investigations of interpolation errors of angle encoders for high precision angle metrology

    NASA Astrophysics Data System (ADS)

    Yandayan, Tanfer; Geckeler, Ralf D.; Just, Andreas; Krause, Michael; Asli Akgoz, S.; Aksulu, Murat; Grubert, Bernd; Watanabe, Tsukasa

    2018-06-01

    Interpolation errors at small angular scales are caused by the subdivision of the angular interval between adjacent grating lines into smaller intervals when radial gratings are used in angle encoders. They are often a major error source in precision angle metrology and better approaches for determining them at low levels of uncertainty are needed. Extensive investigations of interpolation errors of different angle encoders with various interpolators and interpolation schemes were carried out by adapting the shearing method to the calibration of autocollimators with angle encoders. The results of the laboratories with advanced angle metrology capabilities are presented which were acquired by the use of four different high precision angle encoders/interpolators/rotary tables. State of the art uncertainties down to 1 milliarcsec (5 nrad) were achieved for the determination of the interpolation errors using the shearing method which provides simultaneous access to the angle deviations of the autocollimator and of the angle encoder. Compared to the calibration and measurement capabilities (CMC) of the participants for autocollimators, the use of the shearing technique represents a substantial improvement in the uncertainty by a factor of up to 5 in addition to the precise determination of interpolation errors or their residuals (when compensated). A discussion of the results is carried out in conjunction with the equipment used.

  11. The openEHR Java reference implementation project.

    PubMed

    Chen, Rong; Klein, Gunnar

    2007-01-01

    The openEHR foundation has developed an innovative design for interoperable and future-proof Electronic Health Record (EHR) systems based on a dual model approach with a stable reference information model complemented by archetypes for specific clinical purposes.A team from Sweden has implemented all the stable specifications in the Java programming language and donated the source code to the openEHR foundation. It was adopted as the openEHR Java Reference Implementation in March 2005 and released under open source licenses. This encourages early EHR implementation projects around the world and a number of groups have already started to use this code. The early Java implementation experience has also led to the publication of the openEHR Java Implementation Technology Specification. A number of design changes to the specifications and important minor corrections have been directly initiated by the implementation project over the last two years. The Java Implementation has been important for the validation and improvement of the openEHR design specifications and provides building blocks for future EHR systems.

  12. SU-E-T-195: Gantry Angle Dependency of MLC Leaf Position Error

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ju, S; Hong, C; Kim, M

    Purpose: The aim of this study was to investigate the gantry angle dependency of the multileaf collimator (MLC) leaf position error. Methods: An automatic MLC quality assurance system (AutoMLCQA) was developed to evaluate the gantry angle dependency of the MLC leaf position error using an electronic portal imaging device (EPID). To eliminate the EPID position error due to gantry rotation, we designed a reference maker (RM) that could be inserted into the wedge mount. After setting up the EPID, a reference image was taken of the RM using an open field. Next, an EPID-based picket-fence test (PFT) was performed withoutmore » the RM. These procedures were repeated at every 45° intervals of the gantry angle. A total of eight reference images and PFT image sets were analyzed using in-house software. The average MLC leaf position error was calculated at five pickets (-10, -5, 0, 5, and 10 cm) in accordance with general PFT guidelines using in-house software. This test was carried out for four linear accelerators. Results: The average MLC leaf position errors were within the set criterion of <1 mm (actual errors ranged from -0.7 to 0.8 mm) for all gantry angles, but significant gantry angle dependency was observed in all machines. The error was smaller at a gantry angle of 0° but increased toward the positive direction with gantry angle increments in the clockwise direction. The error reached a maximum value at a gantry angle of 90° and then gradually decreased until 180°. In the counter-clockwise rotation of the gantry, the same pattern of error was observed but the error increased in the negative direction. Conclusion: The AutoMLCQA system was useful to evaluate the MLC leaf position error for various gantry angles without the EPID position error. The Gantry angle dependency should be considered during MLC leaf position error analysis.« less

  13. Development of a software package for solid-angle calculations using the Monte Carlo method

    NASA Astrophysics Data System (ADS)

    Zhang, Jie; Chen, Xiulian; Zhang, Changsheng; Li, Gang; Xu, Jiayun; Sun, Guangai

    2014-02-01

    Solid-angle calculations play an important role in the absolute calibration of radioactivity measurement systems and in the determination of the activity of radioactive sources, which are often complicated. In the present paper, a software package is developed to provide a convenient tool for solid-angle calculations in nuclear physics. The proposed software calculates solid angles using the Monte Carlo method, in which a new type of variance reduction technique was integrated. The package, developed under the environment of Microsoft Foundation Classes (MFC) in Microsoft Visual C++, has a graphical user interface, in which, the visualization function is integrated in conjunction with OpenGL. One advantage of the proposed software package is that it can calculate the solid angle subtended by a detector with different geometric shapes (e.g., cylinder, square prism, regular triangular prism or regular hexagonal prism) to a point, circular or cylindrical source without any difficulty. The results obtained from the proposed software package were compared with those obtained from previous studies and calculated using Geant4. It shows that the proposed software package can produce accurate solid-angle values with a greater computation speed than Geant4.

  14. Full-angle tomographic phase microscopy of flowing quasi-spherical cells.

    PubMed

    Villone, Massimiliano M; Memmolo, Pasquale; Merola, Francesco; Mugnano, Martina; Miccio, Lisa; Maffettone, Pier Luca; Ferraro, Pietro

    2017-12-19

    We report a reliable full-angle tomographic phase microscopy (FA-TPM) method for flowing quasi-spherical cells along microfluidic channels. This method lies in a completely passive optical system, i.e. mechanical scanning or multi-direction probing of the sample is avoided. It exploits the engineered rolling of cells while they are flowing along a microfluidic channel. Here we demonstrate significant progress with respect to the state of the art of in-flow TPM by showing a general extension to cells having almost spherical shapes while they are flowing in suspension. In fact, the adopted strategy allows the accurate retrieval of rotation angles through a theoretical model of the cells' rotation in a dynamic microfluidic flow by matching it with phase-contrast images resulting from holographic reconstructions. So far, the proposed method is the first and the only one that permits to get in-flow TPM by probing the cells with full-angle, achieving accurate 3D refractive index mapping and the simplest optical setup, simultaneously. Proof of concept experiments were performed successfully on human breast adenocarcinoma MCF-7 cells, opening the way for the full characterization of circulating tumor cells (CTCs) in the new paradigm of liquid biopsy.

  15. Slow relaxation in weakly open rational polygons.

    PubMed

    Kokshenev, Valery B; Vicentini, Eduardo

    2003-07-01

    The interplay between the regular (piecewise-linear) and irregular (vertex-angle) boundary effects in nonintegrable rational polygonal billiards (of m equal sides) is discussed. Decay dynamics in polygons (of perimeter P(m) and small opening Delta) is analyzed through the late-time survival probability S(m) approximately equal t(-delta). Two distinct slow relaxation channels are established. The primary universal channel exhibits relaxation of regular sliding orbits, with delta=1. The secondary channel is given by delta>1 and becomes open when m>P(m)/Delta. It originates from vertex order-disorder dual effects and is due to relaxation of chaoticlike excitations.

  16. Angle performance on optima MDxt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    David, Jonathan; Kamenitsa, Dennis

    2012-11-06

    Angle control on medium current implanters is important due to the high angle-sensitivity of typical medium current implants, such as halo implants. On the Optima MDxt, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through six narrow slits, and any angle adjustment is made by electrostatically steering the beam, while cross-wafer beam parallelism is adjusted by changing the focus of the electrostatic parallelizing lens (P-lens). In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightlymore » tilting the wafer platen prior to implant. A variety of tests were run to measure the accuracy and repeatability of Optima MDxt's angle control. SIMS profiles of a high energy, channeling sensitive condition show both the cross-wafer angle uniformity, along with the small-angle resolution of the system. Angle repeatability was quantified by running a channeling sensitive implant as a regular monitor over a seven month period and measuring the sheet resistance-to-angle sensitivity. Even though crystal cut error was not controlled for in this case, when attributing all Rs variation to angle changes, the overall angle repeatability was measured as 0.16 Degree-Sign (1{sigma}). A separate angle repeatability test involved running a series of V-curves tests over a four month period using low crystal cut wafers selected from the same boule. The results of this test showed the angle repeatability to be <0.1 Degree-Sign (1{sigma}).« less

  17. Properties of pattern standard deviation in open-angle glaucoma patients with hemi-optic neuropathy and bi-optic neuropathy.

    PubMed

    Heo, Dong Won; Kim, Kyoung Nam; Lee, Min Woo; Lee, Sung Bok; Kim, Chang-Sik

    2017-01-01

    To evaluate the properties of pattern standard deviation (PSD) according to localization of the glaucomatous optic neuropathy. We enrolled 242 eyes of 242 patients with primary open-angle glaucoma, with a best-corrected visual acuity ≥ 20/25, and no media opacity. Patients were examined via dilated fundus photography, spectral-domain optical coherence tomography, and Humphrey visual field examination, and divided into those with hemi-optic neuropathy (superior or inferior) and bi-optic neuropathy (both superior and inferior). We assessed the relationship between mean deviation (MD) and PSD. Using broken stick regression analysis, the tipping point was identified, i.e., the point at which MD became significantly associated with a paradoxical reversal of PSD. In 91 patients with hemi-optic neuropathy, PSD showed a strong correlation with MD (r = -0.973, β = -0.965, p < 0.001). The difference between MD and PSD ("-MD-PSD") was constant (mean, -0.32 dB; 95% confidence interval, -2.48~1.84 dB) regardless of visual field defect severity. However, in 151 patients with bi-optic neuropathy, a negative correlation was evident between "-MD-PSD" and MD (r2 = 0.907, p < 0.001). Overall, the MD tipping point was -14.0 dB, which was close to approximately 50% damage of the entire visual field (p < 0.001). Although a false decrease of PSD usually begins at approximately 50% visual field damage, in patients with hemi-optic neuropathy, the PSD shows no paradoxical decrease and shows a linear correlation with MD.

  18. Trabecular micro-bypass stent implantation during small-incision cataract surgery for open-angle glaucoma or ocular hypertension: Long-term results.

    PubMed

    Neuhann, Tobias H

    2015-12-01

    To evaluate long-term safety and efficacy of iStent trabecular micro-bypass stent implantation during cataract surgery in patients with primary open-angle, pseudo-exfoliation glaucoma, ocular hypertension, or secondary or post-traumatic glaucoma. AaM Augenklinik am Marienplatz, Munich, Germany. Prospective, open-label, non-randomized study. Preoperative and postoperative evaluations included intra-ocular pressure (IOP), topical ocular hypotensive medication use, cup/disc ratio, corrected-distance visual acuity (CDVA), complications, and adverse events. A single trabecular micro-bypass stent was implanted through the same temporal, limbal incision used for cataract surgery via phacoemulsification in a consecutive series of 62 eyes of 43 patients. To date, a total of 41 eyes have been followed for 3 years postoperatively, whereas long-term postoperative follow-up on the remaining patients is ongoing. Mean preoperative IOP was 24.1 ± 6.9 mm Hg on a mean of 1.8 medications (±0.9). Analyses of eyes with no secondary surgical intervention showed mean IOP reduction to 14.8 ± 4.2 mm Hg at 12 months (n = 61), 14.5 ± 2.2 mm Hg at 24 months (n = 42), and 14.9 ± 2.3 mm Hg at 36 months (n = 39). Medications were eliminated in 74% of eyes at 36 months. Five eyes, 4 with previous glaucoma surgeries and 1 with pseudo-exfoliation syndrome, required additional glaucoma surgery after stent implantation. No intra-operative or postoperative complications typically seen with conventional glaucoma surgeries occurred after stent implantation. At 36 months, CDVA was 20/40 or better in 38 eyes (93%). Trabecular micro-bypass stent implantation during cataract surgery was safe and effective in patients with ocular hypertension or glaucoma as measured by a sustained reduction in IOP and medication use and an excellent safety profile through 3 years after surgery. Dr. Neuhann has no financial or proprietary interest in any material or method mentioned. Glaukos Corp. provided editorial

  19. [Changes of structures of anterior chamber angle in rabbit chronic high intraocular pressure model].

    PubMed

    Lei, Xun-wen; Wei, Ping; Li, Xiao-lin; Yang, Kan; Lei, Jian-zhen

    2009-10-01

    To observe the anterior chamber angle changes occurred in compound Carbomer-induced chronic high intraocular pressure (IOP) model in rabbit eyes. It was an experimental study. Thirty two rabbits were randomly divided into eight groups. Compound Carbomer (0.3%, 0.3 ml) was injected into the left anterior chamber. A group of rabbits were randomly killed after 1, 2, 3, 4, 6, 8, 10 and 12 weeks. The anterior chamber of the rabbit eye specimens was observed. IOP increased slowly following the application of the drug, high IOP lasted for 3 months. The drug-induced changes of anterior chamber angle consisted of early inflammatory response and late fibrous changes. Inflammatory response occurred in early stage and reduced or disappeared after 3 weeks. Fibrous degeneration and adhesion obstruction occurred in the anterior chamber angle after 4 weeks. Under the electron microscope, the trabecular was expanded and deformed, with hyperplasia of collagen and elastic fibers. Endothelial cells were separated from the trabecular, and showed the morphology of lymphocytes, with the function similar to the macrophages. Phagocytized Carbomer particles were transported through the vacuoles of Schlemm's canal endothelial cells. Large vacuoles gradually reduced. Excessive Carbomer particles were accumulated in the endothelial cells and obstructed the Schlemm's canal. This induced the fibrous proliferation and the destruction of anterior chamber angle structures. The obstruction of aqueous humor outflow induced by compound Carbomer in rabbit high IOP model is caused mainly by the changes in trabecular endothelial cells.

  20. Pathological (late) fractures of the mandibular angle after lower third molar removal: a case series.

    PubMed

    Cutilli, Tommaso; Bourelaki, Theodora; Scarsella, Secondo; Fabio, Desiderio Di; Pontecorvi, Emanuele; Cargini, Pasqualino; Junquera, Luis

    2013-04-30

    Pathological (late) fracture of the mandibular angle after third molar surgery is very rare (0.005% of third molar removals). There are 94 cases reported in the literature; cases associated with osseous pathologies such as osteomyelitis or any local and systemic diseases that may compromise mandibular bone strength have not been included. We describe three new cases of pathological (late) fracture of the mandibular angle after third molar surgery. The first patient was a 27-year-old Caucasian man who had undergone surgical removal of a 3.8, mesioangular variety, class II-C third molar 20 days before admission to our clinic. The fracture of his left mandibular angle, complete and composed, occurred during chewing. The second patient was a 32-year-old Caucasian man. He had undergone surgical removal of a 3.8, mesioangular variety, class II-B third molar 22 days before his admission. The fracture, which occurred during mastication, was studied by computed tomography that showed reparative tissue in the fracture site. The third patient was a 36-year-old Caucasian man who had undergone surgical removal of a 3.8, vertical variety, class II-C third molar 25 days before the observation. In this case the fracture of his mandibular angle was oblique (unfavorable), complete and composed. The fracture had occurred during chewing. We studied the fracture by optical projection tomography and computed tomography.All of the surgical removals of the 3.8 third molars, performed by the patients' dentists who had more than 10 years of experience, were difficult. We treated the fractures with open surgical reduction, internal fixation by titanium miniplates and intermaxillary elastic fixation removed after 6 weeks. The literature indicates that the risk of pathological (late) fracture of the mandibular angle after third molar surgery for total inclusions (class II-III, type C) is twice that of partial inclusions due to the necessity of ostectomies more generous than those for partial

  1. The influence of third molars in the line of mandibular angle fractures on wound and bone healing.

    PubMed

    Ulbrich, N; Ettl, T; Waiss, W; Gosau, M; Moralis, A; Reichert, T E; Mueller, S

    2016-07-01

    The objective of this study was to evaluate postoperative complications after removal or retention of the third molar in the line of mandibular angle fractures. This retrospective study included the data of 98 patients with a molar in the line of a mandibular angle fracture treated with internal reduction and mini-plate fixation at our department over 9 years. Patients were classified into two groups: tooth removal during osteosynthesis (n = 45) and tooth retention (n = 55). The primary target criterion was the incidence of minor (outpatient treatment, local measures) and major (surgical revision, rehospitalisation) complications. Time between trauma and surgery was 1.4 days (range 0 to 12), and the average follow-up 291 days (range 66 to 863). Regarding the eruption status, 26 of 52 (50.0 %) impacted third molars, 11 of 19 (57.9 %) incompletely erupted and 8 of 27 (29.6 %) completely erupted molars had been removed during open reduction. Overall, 17 (17.3 %) patients had postoperative minor (n = 7) or major (n = 10) complications, in detail 10/45 (22.0 %) patients after tooth removal and 7/55 (13 %) patients after tooth retention (p = 0.286). Complication rates between impacted and incompletely erupted third molars (impacted molars 15.0 %, incompletely erupted molars 10.0 %) did not differ significantly, but completely erupted molars had a complication rate of 26.0 %. Mandibular angle fractures with a completely erupted third molar show the highest complication rate after open reduction and osteosynthesis. Retention of a non-infectious third molar facilitates open reduction and does not increase the complication risk. The study helps with the decision of removing or retention of a third molar during surgical treatment of a mandibular angle fracture.

  2. Changes in the retrobulbar arterial circulation after decrease of elevated intraocular pressue in patients with primary open angle glaucoma.

    PubMed

    Marjanović, Ivan; Sundić, Ana; Mijajlović, Milija; Covicković-Sternić, Nadezda; Kontić, Djordje; Hentova-Senćanić, Paraskeva; Marković, Vujica; Bozić, Marija; Knezević, Miroslav

    2011-01-01

    An altered perfusion of the optic nerve head has been proposed as a pathogenic factor in glaucoma. To evaluate changes of haemodynamic parameters in the retrobulbar arterial circulation after a decrease of elevated intraocular pressure (IOP) in patients with primary open angle glaucoma (POAG). Twenty-six patients were examined, 14 men and 12 women, 21 up to 50 years old and 5 below, all with previously diagnosed and treated POAG, and all examined at the Eye Clinic, Clinical Centre of Serbia. IOP was measured both with a Goldmann aplanation tonometer and dynamic contour tonometer. Central corneal thickness was measured with ultrasound pachymeter. Imaging of the retrobulbar arterial circulation by colour Doppler was performed at the Neurology Clinic, Clinical Centre of Serbia. It involved measuring of haemodynamic parameters of the ophthalmic artery, central retinal artery, and posterior ciliary arteries. Peak systolic velocity (PSV) and end-diastolic velocity (EDV) were measured, and resistive index (RI) and pulsatility index (PI) were calculated. Haemodynamic arterial parameters PSV and EDV in the ophthalmic and central retinal artery after decrease of IOP were lower, while RI and PI were higher. In the posterior ciliary arteries PSV, EDV and PI were lower, and RI was higher. Changes of the retrobulbar arterial circulation after elevated LOP in POAG patients are important for approach and treatment, while the role of vascular factors in the supplement of the optic disc neuroretinal rim could be a key for progression backlash of glaucoma and the radix of neuroprotection.

  3. 78 FR 36202 - Notice of Open Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-17

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health Notice of Open Meeting SUMMARY: The National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK), a research.... This webinar is free and open to the public. Early registration is requested, registration requests...

  4. Comparison of the cable pin system with conventional open surgery for transverse patella fractures.

    PubMed

    Mao, Ningfang; Liu, Deding; Ni, Haijian; Tang, Hao; Zhang, Qiulin

    2013-07-01

    The cable pin system is an effective device for fixation of transverse patella fractures. However, whether this device provides superior results using a minimally invasive technique instead of conventional open surgery using the K wire tension band method is unclear. We asked whether a minimally invasive technique would be associated with (1) increased operative time; (2) reduced postoperative pain; (3) faster recovery of ROM; (4) higher knee scores; and (5) reduced complications. Forty patients with displaced transverse fractures of the patella participated in this prospective, randomized, controlled trial. Twenty of these patients underwent a minimally invasive technique and the others had conventional open surgery using K wires. Some data for six of the 20 patients who underwent the minimally invasive technique were published in an earlier prospective, observational trial. At postoperative intervals of 1, 3, 6, 12, and 24 months, pain was measured by VAS scores, active flexion and extension of the knee were measured in degrees by goniometry, and knee function was evaluated using the Böstman clinical grading scale. Operative time was longer in the minimally invasive surgery group (54.3 ± 9.8 minutes versus 48.5 ± 6.1 minutes). Pain scores were better (lower) in the minimally invasive surgery group at 1 and 3 months but not at 6 months. Early flexion, ultimate flexion, and knee scores from 3 to 24 months, likewise, were better in the minimally invasive surgery group. Complications mostly related to symptomatic hardware were less common in the minimally invasive surgery group. The minimally invasive technique is superior to conventional open surgery using K wires in terms of less early postoperative pain, better mobility angles of the injured knee, higher functional score of the injured knee, and decreased incidence of complications. Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  5. Ultra-high resolution profiles of macular intra-retinal layer thicknesses and associations with visual field defects in primary open angle glaucoma

    NASA Astrophysics Data System (ADS)

    Chen, Qi; Huang, Shenghai; Ma, Qingkai; Lin, Huiling; Pan, Mengmeng; Liu, Xinting; Lu, Fan; Shen, Meixiao

    2017-02-01

    The structural characteristics of the outer retinal layers in primary open angle glaucoma (POAG) are still controversial, and these changes, along with those in the inner retinal layers, could have clinical and/or pathophysiological significance. A custom-built ultra-high resolution optical coherence tomography (UHR-OCT) combined with an automated segmentation algorithm can image and measure the eight intra-retinal layers. The purpose of this study is to determine the thickness characteristics of the macular intra-retinal layers, especially the outer layers, in POAG patients. Thirty-four POAG patients (56 eyes) and 33 normal subjects (63 eyes) were enrolled. Thickness profiles of the eight intra-retinal layers along a 6-mm length centred on the fovea at the horizontal and vertical meridians were obtained and the regional thicknesses were compared between two groups. The associations between the thicknesses of each intra-retinal layer and the macular visual field (VF) sensitivity were then analysed. POAG affected not only the inner retinal layers but also the photoreceptor layers and retinal pigment epithelium of the outer retina. However, the VF loss was correlated mainly with the damage of the inner retinal layers. UHR-OCT with automated algorithm is a useful tool in detecting microstructural changes of macula with respect to the progression of glaucoma.

  6. A cost-effectiveness analysis of fixed-combination therapies in patients with open-angle glaucoma: a European perspective.

    PubMed

    Hommer, A; Wickstrøm, J; Friis, M M; Steeds, C; Thygesen, J; Ferreras, A; Gouws, P; Buchholz, P

    2008-04-01

    To compare the efficacy and cost implications of the use of the intraocular pressure-lowering prostaglandin analogues bimatoprost, travoprost, and latanoprost as fixed-combination therapies with timolol, a beta-adrenergic receptor antagonist. A decision analytic cost-effectiveness model was constructed. Since no head-to-head studies comparing the three treatment options exist, the analysis was based on an indirect comparison. Hence, the model was based on efficacy data from five randomized, controlled, clinical studies. The studies were comparable with respect to study design, time horizon, patient population and type of end point presented. The measure of effectiveness was the percentage reduction of the intraocular pressure level from baseline. The cost evaluated was the cost of medication and clinical visits to the ophthalmologist. All drug costs were market prices inclusive of value-added tax, and visit costs were priced using official physician fees. Cost-effectiveness analyses were carried out in five European countries: Spain, Italy, United Kingdom, Norway and Sweden. The time horizon for the analyses was 3 months. The analysis showed that fixed-combination bimatoprost/timolol was more effective and less costly than fixed-combination travoprost/timolol and fixed-combination latanoprost/timolol in three out of the five countries analyzed. In two countries, bimatoprost/timolol was less costly than latanoprost/timolol, and cost the same as travoprost/timolol. This cost-effectiveness analysis showed that the fixed combination of bimatoprost 0.03%/timolol 0.5% administered once daily was a cost-effective treatment option for patients with primary open-angle glaucoma. This study was limited by available clinical data: without a head-to-head trial, indirect comparisons were necessary. In the United Kingdom, Sweden, Norway, Italy, and Spain, from a health service viewpoint, bimatoprost/timolol was a slightly more effective as well as less costly treatment strategy

  7. A Missing Puzzle Piece in Murray's Law: the Optimal Angle of Junctions

    NASA Astrophysics Data System (ADS)

    Wang, Ruo-Qian; Taylor, Katherine; Winter, Amos G.; Global Engineering; Research Lab Team

    2014-11-01

    Branching flows are common in biological systems, such as the circulatory and respiratory systems of animals. The optimal radii of parent and daughter branches can be explained with Murray's law, which dictates that the sum of metabolic and pumping costs is minimized. Murray's Law can be used to determine the diameter of cascading channels but misses an important parameter: the angles of the branches. Past hydraulic studies have investigated the angle effect, but have not focused on whether this geometry follows Murray's Law; while a simple network optimization is able to show that at low Reynolds numbers a branch with a parent channel connecting to n equally distant channels obeying Murray's Law has a minimum total head loss with a branching angle θ, such that cos θ =n-2/3 , but it's not valid for high Reynolds number flows, which may experience separation and turbulence at the branches. The present study is focused on determining the optimal branch angle that complies with Murray's Law for moderate Reynolds numbers. Computational studies using Open FOAM and experiments using 3D printed branched channels will be presented. These results will be used to quantify the effect of Reynolds number on optimal branch geometry.

  8. Comparison of a technique using a new percutaneous osteosynthesis device with conventional open surgery for displaced patella fractures in a randomized controlled trial.

    PubMed

    Luna-Pizarro, Daniel; Amato, Dante; Arellano, Francisco; Hernández, Armando; López-Rojas, Pablo

    2006-09-01

    To compare the percutaneous patellar osteosynthesis system (PPOS) technique with open surgery for patella fractures. Randomized controlled trial. Referral orthopedic and trauma center. Fifty-three patients with displaced patellar fractures. Stabilization and fixation of patellar fractures with PPOS or open surgery. Knee-flexion and -extension angles, pain, surgical time, and assessment of knee function based on the Knee Society Clinical Rating Scale (KSCRS). Comparison of PPOS and open-surgery groups at 4 weeks showed the following: pain, 3.7 +/- 1.6 versus 6.2 +/- 1.4 arbitrary units, P < 0.001; flexion angle, 46 +/- 20.7 versus 12.7 +/- 6.0 degrees, P < 0.001; extension angle, -2.5 versus -3.8 degrees, P < 0.001. At 8 weeks, the following was demonstrated: pain, 1.3 +/- 1.6 versus 4.1 +/- 2.1 arbitrary units, P < 0.001; flexion angle, 87 +/- 17.3 versus 34 +/- 26 degrees, P < 0.001; extension angle, 0 versus -3 degrees, P < 0.001. Surgical time was 35.3 +/- 7.8 versus 66.2 +/- 14.1 minutes, P < 0.001. KSCRS assessment was 84 +/- 4 versus 70 +/- 8, P < 0.001 at 8 weeks; 85 +/- 2 versus 73 +/- 8, P < 0.001 at 12 months; and 85 +/- 1 versus 82 +/- 7, P = 0.246 at 24 months. Frequency of total complications (infections, fragment displacement, and wire-related pain) was significantly lower in the PPOS than in the open-surgery group (P < 0.02). PPOS for patella fractures was associated with shorter surgical time, less pain, better mobility angles, higher functional score up to 2 years, and a lower incidence of complications than open surgery.

  9. Alternate promoter selection within a human cytomegalovirus immediate-early and early transcription unit (UL119-115) defines true late transcripts containing open reading frames for putative viral glycoproteins.

    PubMed Central

    Leatham, M P; Witte, P R; Stinski, M F

    1991-01-01

    The human cytomegalovirus open reading frames (ORFs) UL119 through UL115 (UL119-115) are located downstream of the immediate-early 1 and 2 transcription units. The promoter upstream of UL119 is active at all times after infection and drives the synthesis of a spliced 3.1-kb mRNA. The viral mRNA initiates in UL119, contains UL119-117 and UL116, and terminates just downstream of UL115. True late transcripts that are detected only after viral DNA synthesis originate from this transcription unit. True late mRNAs of 2.1 kb, containing ORFs UL116 and UL115, and 1.2 kb, containing ORF UL115 only, are synthesized. The true late viral mRNAs are 3' coterminal with the 3.1-kb mRNA. This transcription unit is an example of late promoters nested within an immediate-early-early transcription unit. The gene products of UL119-117, UL116, and UL115 are predicted to be glycoproteins. Efficient expression of the downstream ORFs at late times after infection may be related to alternate promoter usage and downstream cap site selection. Images PMID:1717716

  10. Effect and safety of early weight-bearing on the outcome after open-wedge high tibial osteotomy: a systematic review and meta-analysis.

    PubMed

    Lee, O-Sung; Ahn, Soyeon; Lee, Yong Seuk

    2017-07-01

    The purpose of this systematic review and meta-analysis was to evaluate the effectiveness and safety of early weight-bearing by comparing clinical and radiological outcomes between early and traditional delayed weight-bearing after OWHTO. A rigorous and systematic approach was used. The methodological quality was also assessed. Results that are possible to be compared in two or more than two articles were presented as forest plots. A 95% confidence interval was calculated for each effect size, and we calculated the I 2 statistic, which presents the percentage of total variation attributable to the heterogeneity among studies. The random-effects model was used to calculate the effect size. Six articles were included in the final analysis. All case groups were composed of early full weight-bearing within 2 weeks. All control groups were composed of late full weight-bearing between 6 weeks and 2 months. Pooled analysis was possible for the improvement in Lysholm score, but there was no statistically significant difference shown between groups. Other clinical results were also similar between groups. Four studies reported mechanical femorotibial angle (mFTA) and this result showed no statistically significant difference between groups in the pooled analysis. Furthermore, early weight-bearing showed more favorable results in some radiologic results (osseointegration and patellar height) and complications (thrombophlebitis and recurrence). Our analysis supports that early full weight-bearing after OWHTO using a locking plate leads to improvement in outcomes and was comparable to the delayed weight-bearing in terms of clinical and radiological outcomes. On the contrary, early weight-bearing was more favorable with respect to some radiologic parameters and complications compared with delayed weight-bearing.

  11. Angle classification revisited 2: a modified Angle classification.

    PubMed

    Katz, M I

    1992-09-01

    Edward Angle, in his classification of malocclusions, appears to have made Class I a range of abnormality, not a point of ideal occlusion. Current goals of orthodontic treatment, however, strive for the designation "Class I occlusion" to be synonymous with the point of ideal intermeshing and not a broad range. If contemporary orthodontists are to continue to use Class I as a goal, then it is appropriate that Dr. Angle's century-old classification, be modified to be more precise.

  12. Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: A systematic review and meta-analysis

    PubMed Central

    Maule, Milena; Ceccarelli, Manuela; Fea, Antonio Maria

    2017-01-01

    Background MIGS have been developed as a surgical alternative for glaucomatous patients. Purpose To analyze the change in intraocular pressure (IOP) and glaucoma medications using different MIGS devices (Trabectome, iStent, Excimer Laser Trabeculotomy (ELT), iStent Supra, CyPass, XEN, Hydrus, Fugo Blade, Ab interno canaloplasty, Goniscopy-assisted transluminal trabeculotomy) as a solo procedure or in association with phacoemulsification. Methods Randomized control trials (RCT) and non-RCT (non randomized comparative studies, NRS, and before-after studies) were included. Studies with at least one year of follow-up in patients affected by primary open angle glaucoma, pseudoexfoliative glaucoma or pigmentary glaucoma were considered. Risk of Bias assessment was performed using the Cochrane Risk of Bias and the ROBINS-I tools. The main outcome was the effect of MIGS devices compared to medical therapy, cataract surgery, other glaucoma surgeries and other MIGS on both IOP and use of glaucoma medications 12 months after surgery. Outcomes measures were the mean difference in the change of IOP and glaucoma medication compared to baseline at one and two years and all ocular adverse events. The current meta-analysis is registered on PROSPERO (reference n° CRD42016037280). Results Over a total of 3,069 studies, nine RCT and 21 case series with a total of 2.928 eyes were included. Main concerns about risk of bias in RCTs were lack of blinding, allocation concealment and attrition bias while in non-RCTs they were represented by patients’ selection, masking of participants and co-intervention management. Limited evidence was found based on both RCTs and non RCTs that compared MIGS surgery with medical therapy or other MIGS. In before-after series, MIGS surgery seemed effective in lowering both IOP and glaucoma drug use. MIGS showed a good safety profile: IOP spikes were the most frequent complications and no cases of infection or BCVA loss due to glaucoma were reported

  13. Using filtered forecasting techniques to determine personalized monitoring schedules for patients with open-angle glaucoma.

    PubMed

    Schell, Greggory J; Lavieri, Mariel S; Helm, Jonathan E; Liu, Xiang; Musch, David C; Van Oyen, Mark P; Stein, Joshua D

    2014-08-01

    To determine whether dynamic and personalized schedules of visual field (VF) testing and intraocular pressure (IOP) measurements result in an improvement in disease progression detection compared with fixed interval schedules for performing these tests when evaluating patients with open-angle glaucoma (OAG). Secondary analyses using longitudinal data from 2 randomized controlled trials. A total of 571 participants from the Advanced Glaucoma Intervention Study (AGIS) and the Collaborative Initial Glaucoma Treatment Study (CIGTS). Perimetric and tonometric data were obtained for AGIS and CIGTS trial participants and used to parameterize and validate a Kalman filter model. The Kalman filter updates knowledge about each participant's disease dynamics as additional VF tests and IOP measurements are obtained. After incorporating the most recent VF and IOP measurements, the model forecasts each participant's disease dynamics into the future and characterizes the forecasting error. To determine personalized schedules for future VF tests and IOP measurements, we developed an algorithm by combining the Kalman filter for state estimation with the predictive power of logistic regression to identify OAG progression. The algorithm was compared with 1-, 1.5-, and 2-year fixed interval schedules of obtaining VF and IOP measurements. Length of diagnostic delay in detecting OAG progression, efficiency of detecting progression, and number of VF and IOP measurements needed to assess for progression. Participants were followed in the AGIS and CIGTS trials for a mean (standard deviation) of 6.5 (2.8) years. Our forecasting model achieved a 29% increased efficiency in identifying OAG progression (P<0.0001) and detected OAG progression 57% sooner (reduced diagnostic delay) (P = 0.02) than following a fixed yearly monitoring schedule, without increasing the number of VF tests and IOP measurements required. The model performed well for patients with mild and advanced disease. The model

  14. [Spectral Study on the Effects of Angle-Tuned Filter Wedge Angle Parameter to Reflecting Characteristics].

    PubMed

    Yu, Kan; Huang, De-xiu; Yin, Juan-juan; Bao, Jia-qi

    2015-08-01

    Three-port tunable optical filter is a key device in the all-optic intelligent switching network and dense wavelength division multiplexing system. The characteristics of the reflecting spectrum, especially the reflectivity and the isolation degree are very important to the three-port filter. Angle-tuned thin film filter is widely used as a three-port tunable filter for its high rectangular degree and good temperature stability. The characteristics of the reflecting spectrum are greatly influenced not only by the incident angle, but also by the wedge angle parameter of the non-paralleled wedge thin film filter. In the present paper, the influences of the wedge angle parameter to the reflectivity and the half bandwidth are analyzed, and the reflecting spectrum characterstics are simulationed in different wedge angle parameter and polarity. The wedge angle-tuned thin film filter with 0.8° wedge angle parameter is fabricated. The experimental results show that keeping the wedge angle the same orientation to the incident angle will worsen the reflectivity and the rectangular degree of the reflecting spectrum. However, keeping the wedge angle orientation reverse to the incident angle will enhance the reflectivity and decrease the bandwidth, which will give higher reflectivity and isolation degree to the three-port filter than that of high parallel degree angle-tuned thin film filter.

  15. Phase III Early Restoration Meeting | NOAA Gulf Spill Restoration

    Science.gov Websites

    Louisiana Mississippi Texas Region-wide Open Ocean Data Media & News Publications Press Releases Story programmatic approach to early restoration planning for Phase III and future early restoration plans. Open

  16. Phase III Early Restoration Meeting - Pensacola, FL (rescheduled) | NOAA

    Science.gov Websites

    Restoration Areas Alabama Florida Louisiana Mississippi Texas Region-wide Open Ocean Data Media & News programmatic approach to early restoration planning for Phase III and future early restoration plans. Open

  17. Prospective, unmasked evaluation of the iStent® inject system for open-angle glaucoma: synergy trial.

    PubMed

    Voskanyan, Lilit; García-Feijoó, Julián; Belda, Jose I; Fea, Antonio; Jünemann, Anselm; Baudouin, Christophe

    2014-02-01

    Micro-invasive glaucoma surgical implantation of trabecular micro-bypass stents, previously shown to be safe and effective for open-angle glaucoma (OAG) subjects during cataract surgery, was considered for evaluation as a sole procedure. The aim of this study was to evaluate the safety and intraocular pressure (IOP)-lowering efficacy after ab interno implantation of two Glaukos Trabecular Micro-Bypass iStent inject second generation devices in subjects with OAG. This study was performed at sites in France, Germany, Italy, Republic of Armenia, and Spain. In this pan-European, multi-center prospective, post-market, unmasked study, 99 patients with OAG on at least two topical ocular hypotensive medications who required additional IOP lowering to control glaucoma disease underwent implantation of two GTS400 stents in a stand-alone procedure. Patients were qualified if they presented with preoperative mean IOP between 22 and 38 mmHg after medication washout. Postoperatively, subjects were assessed at Day 1, Months 1, 3, 6, 7, 9, and 12. IOP, medication use and safety were assessed at each visit. Sixty-six percent of subjects achieved IOP ≤18 mmHg at 12 months without medication, and 81% of subjects achieved Month 12 IOP ≤ 18 mmHg with either a single medication or no medication. Mean baseline washout IOP values decreased by 10.2 mmHg or 39.7% from 26.3 (SD 3.5) mmHg to 15.7 (SD 3.7) mmHg at Month 12. Mean IOP at 12 months was 14.7 (SD 3.1) mmHg in subjects not using ocular hypotensive medications. Reduction from preoperative medication burden was achieved in 86.9% of patients, including 15.2% with reduction of one medication and 71.7% with reduction of two or more medications. Postoperative complications occurred at a low rate and resolved without persistent effects. In this series, implantation of two trabecular micro-bypass second generation stents in subjects with OAG resulted in IOP and medication reduction and favorable safety outcomes.

  18. Analysis of Balance Ability Dependent on the Angle of the Knee Joint in Females in Their 20s

    PubMed Central

    Yoon, Se-Won; Lee, Jeong-Woo; Cho, Woon-Su; Kim, An-Na; Lee, Kyung-Hee

    2013-01-01

    The aim of this study was to investigate how balance ability according to angle of the knee joint changes in young female adults wearing a knee orthosis. [Methods] This study was conducted with 11 healthy female adults. The subjects used a knee brace that could be set to angles of 0°, 15°, and 30° of knee flexion. The ability to balance was evaluated by balance assessment. A total of four postures were used for measurements: a forward-facing posture with the eyes open on a stable surface (NO), a forward-facing posture with the eyes closed on a stable surface (NC), a forward-facing posture with the eyes open on an unstable surface (PO), and a forward-facing posture with the eyes closed on an unstable surface (PC). [Results] Regarding the weight distribution index and stability index on a stable surface, there was no interaction according to whether there was visual deprivation or not or according to knee flexion angle. Furthermore, the stability index on an unstable surface showed no interaction according to whether there was visual deprivation or not or according to knee flexion angle. But the WDI on a stable surface showed no interaction according to whether there was visual deprivation or not or according to knee flexion angle. [Conclusion] There were significant differences in the knee extension range of motion of normal elderly people and knee osteoarthritis, and the quadriceps femoris played an important role in knee function in individuals with knee osteoarthritis. PMID:24259902

  19. Determinants of lens vault and association with narrow angles in patients from Singapore.

    PubMed

    Tan, Gavin S; He, Mingguang; Zhao, Wanting; Sakata, Lisandro M; Li, Jialiang; Nongpiur, Monisha E; Lavanya, Raghavan; Friedman, David S; Aung, Tin

    2012-07-01

    To describe the distribution and determinants of lens vault and to investigate the association of lens vault with narrow angles. Prospective cross-sectional study. Phakic subjects 50 years and older were evaluated at a primary healthcare clinic with gonioscopy, partial laser interferometry, and anterior segment optical coherence tomography (AS-OCT). Narrow angles were defined as posterior trabecular meshwork not visible for ≥2 quadrants on non-indentation gonioscopy. Lens vault was defined as the perpendicular distance between the anterior pole of the crystalline lens and the horizontal line joining the 2 scleral spurs on horizontal AS-OCT scans. Analysis of covariance, multivariate logistic regression, and area under the receiver operating characteristic curves (AUC) were performed. Of the 2047 subjects recruited, 582 were excluded because of poor image quality or inability to locate scleral spurs, leaving 1465 subjects for analysis. Eyes with narrow angles had greater lens vault compared to eyes with open angles (775.6 µm vs 386.5 µm, P < .0001). Women had significantly greater lens vault than men (497.28 µm vs 438.56 µm, P < .001), and lens vault increased significantly with age (P for trend <.001). Adjusted for age and sex, significant associations with greater lens vault were shorter axial length, shallower anterior chamber depth(ACD), higher intraocular pressure, and more hyperopic spherical equivalent (all P < .001). On multivariate analysis, subjects with lens vault >667.6 µm were more likely to have narrow angles (OR 2.201, 95% CI: 1.070-4.526) compared to those with lens vault ≤462.7 µm. The AUC for lens vault (0.816) and ACD (0.822) for detecting narrow angles were similar (P = .582). Lens vault was independently associated with narrow angles and may be useful in screening to detect eyes with narrow angles. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Angle Performance on Optima XE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    David, Jonathan; Satoh, Shu

    2011-01-07

    Angle control on high energy implanters is important due to shrinking device dimensions, and sensitivity to channeling at high beam energies. On Optima XE, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through a series of narrow slits, and any angle adjustment is made by steering the beam with the corrector magnet. In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightly tilting the wafer platen during implant.Using a sensitive channeling condition, we were ablemore » to quantify the angle repeatability of Optima XE. By quantifying the sheet resistance sensitivity to both horizontal and vertical angle variation, the total angle variation was calculated as 0.04 deg. (1{sigma}). Implants were run over a five week period, with all of the wafers selected from a single boule, in order to control for any crystal cut variation.« less

  1. An observational study of bimatoprost 0.01% in treatment-naïve patients with primary open angle glaucoma or ocular hypertension: the CLEAR trial

    PubMed Central

    Nixon, Donald R; Simonyi, Susan; Bhogal, Meetu; Sigouin, Christopher S; Crichton, Andrew C; Discepola, Marino; Hutnik, Cindy ML; Yan, David B

    2012-01-01

    Background This study was designed to evaluate the occurrence and severity of ocular hyperemia in subjects with elevated intraocular pressure (IOP) due to primary open angle glaucoma (POAG) or ocular hypertension (OHT) following treatment with bimatoprost 0.01% in a real-world clinical setting. Methods This was an open-label, observational study conducted at 67 centers in Canada. Subjects with elevated IOP due to POAG or OHT instilled bimatoprost 0.01% topically as monotherapy once daily. Ocular hyperemia was graded by the investigator at baseline and weeks 6 and 12 using a photographic five-point grading scale. Change in IOP from baseline was also evaluated at these time points. This analysis includes only the subgroup of 522 subjects who were naïve to IOP-lowering medication prior to the study. Results After 12 weeks of treatment with bimatoprost 0.01%, hyperemia was graded as none-to-mild (grades 0, +0.5, or +1) for 93.3% of subjects and as moderate-to-severe (grades +2 or +3) for 6.7%. At weeks 6 and 12, most subjects (93.2% and 93.5%) had no change in hyperemia grade from baseline. IOP was reduced by 7.4 mmHg (29.8%) at week 6 and 7.7 mmHg (30.9%) at week 12 from baseline. Conclusion This real-world, observational study found that bimatoprost 0.01% instilled once daily reduced IOP by a mean of 30% from baseline without moderate or severe ocular hyperemia in 93% of treatment-naïve subjects with POAG or OHT. PMID:23269858

  2. Manifold angles, the concept of self-similarity, and angle-enhanced bifurcation diagrams

    PubMed Central

    Beims, Marcus W.; Gallas, Jason A. C.

    2016-01-01

    Chaos and regularity are routinely discriminated by using Lyapunov exponents distilled from the norm of orthogonalized Lyapunov vectors, propagated during the temporal evolution of the dynamics. Such exponents are mean-field-like averages that, for each degree of freedom, squeeze the whole temporal evolution complexity into just a single number. However, Lyapunov vectors also contain a step-by-step record of what exactly happens with the angles between stable and unstable manifolds during the whole evolution, a big-data information permanently erased by repeated orthogonalizations. Here, we study changes of angles between invariant subspaces as observed during temporal evolution of Hénon’s system. Such angles are calculated numerically and analytically and used to characterize self-similarity of a chaotic attractor. In addition, we show how standard tools of dynamical systems may be angle-enhanced by dressing them with informations not difficult to extract. Such angle-enhanced tools reveal unexpected and practical facts that are described in detail. For instance, we present a video showing an angle-enhanced bifurcation diagram that exposes from several perspectives the complex geometrical features underlying the attractors. We believe such findings to be generic for extended classes of systems. PMID:26732416

  3. Manifold angles, the concept of self-similarity, and angle-enhanced bifurcation diagrams

    NASA Astrophysics Data System (ADS)

    Beims, Marcus W.; Gallas, Jason A. C.

    2016-01-01

    Chaos and regularity are routinely discriminated by using Lyapunov exponents distilled from the norm of orthogonalized Lyapunov vectors, propagated during the temporal evolution of the dynamics. Such exponents are mean-field-like averages that, for each degree of freedom, squeeze the whole temporal evolution complexity into just a single number. However, Lyapunov vectors also contain a step-by-step record of what exactly happens with the angles between stable and unstable manifolds during the whole evolution, a big-data information permanently erased by repeated orthogonalizations. Here, we study changes of angles between invariant subspaces as observed during temporal evolution of Hénon’s system. Such angles are calculated numerically and analytically and used to characterize self-similarity of a chaotic attractor. In addition, we show how standard tools of dynamical systems may be angle-enhanced by dressing them with informations not difficult to extract. Such angle-enhanced tools reveal unexpected and practical facts that are described in detail. For instance, we present a video showing an angle-enhanced bifurcation diagram that exposes from several perspectives the complex geometrical features underlying the attractors. We believe such findings to be generic for extended classes of systems.

  4. Diagnostic accuracy of ganglion cell complex substructures in different stages of primary open-angle glaucoma.

    PubMed

    Elbendary, Amal M; Abd El-Latef, Mohamed Hafez; Elsorogy, Hisham I; Enaam, Kamal M

    2017-08-01

    To evaluate diagnostic accuracy of substructure of ganglion cell complex versus peripapillary nerve fiber layer (NFL) thickness using spectral domain optical coherence tomography (SD-OCT) in different stages of glaucoma. Thirty eyes were normal, 120 were glaucomatous. Glaucomatous eyes were classified into: early glaucoma (46), moderate glaucoma (48), and severe glaucoma (26). Perimetry and SD-OCT were done. Peripapillary NFL thickness, ganglion cell layer (GCL), macular NFL thickness, combined GCL and macular ganglion cell complex (GCC), were recorded. Area under receiver operating characteristic curves (AUCs) was used to verify performance of different OCT parameters. Peripapillary NFL, GCL, and GCC thickness values were significantly different in all stages of glaucoma. All comparisons were significantly different; normal versus early, early versus moderate and moderate versus severe. The best parameters that distinguished normal from early stage were: peripapillary NFL (AUC: 0.90), GCC (AUC: 0.75), early from moderate stage were: peripapillary NFL thickness (AUC: 0.85), GCL (0.81),GCC (0.81), moderate from severe stage were: GCC (AUC:0.95), macular NFL (AUC:0.91), GCL (AUC:0.89), and peripapillary NFL (AUC:0.88). Peripapllary NFL and GCC thinning showed paradoxical course. The most diagnosed parameter in early glaucoma was peripapillary NFL and in severe glaucoma was GCC. In severe glaucoma, macular NFL showed higher diagnostic power than GCL and peripapillary NFL. Ganglion cell complex mapping may provide good alternative to optic disc imaging in advanced glaucoma with poor fixation. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  5. Risk factors for predicting visual field progression in Chinese patients with primary open-angle glaucoma: A retrospective study.

    PubMed

    Hung, Kuo-Hsuan; Cheng, Ching-Yu; Liu, Catherine Jui-Ling

    2015-07-01

    Glaucoma is a leading cause of irreversible blindness worldwide. It is characterized by progressive deterioration of the visual field (VF) that results in a complete loss of vision. This study aimed to determine the risk factors associated with VF progression in Chinese patients with primary open-angle glaucoma (POAG). We reviewed the charts of POAG patients who visited our clinic between July 2009 and June 2010. We included patients with five or more reliable VF tests using the Humphrey Field Analyzer (Humphrey Instruments, San Leandro, CA, USA) during a period of at least 2 years. The scoring system of the Collaborative Initial Glaucoma Treatment Study (CIGTS) was used to code the VF. Progression was defined as an increasing score ≥3, compared to the averaged baseline data. Univariate and multivariate logistic regression analyses were performed to identify the risk factors of VF progression. There were 92 patients (representing 92 eyes) with an average of 8.9 reliable VFs over a mean follow up of 5.4 years. Multivariate logistic regression showed that eyes with more VF tests [odds ratio (OR) = 1.500, p < 0.010] and either increased peak intraocular pressure (IOP) (OR = 1.235, p = 0.044) or a wide IOP range (OR = 1.165, p = 0.041) favored VF progression. High myopia (less than -6.0 D) was not a risk factor (OR = 1.289, p = 0.698) for VF progression in this study. In addition to a greater number of VF tests, Chinese patients with treated POAG who experienced a high peak IOP or a wide range of IOP during follow up were more likely to have VF deterioration. Copyright © 2015. Published by Elsevier Taiwan.

  6. Relationship between consecutive deterioration of mean deviation value and progression of visual field defect in open-angle glaucoma.

    PubMed

    Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Takeda, Ryuji; Shiraga, Fumio

    2015-01-01

    To analyze the relationship between consecutive deterioration of mean deviation (MD) value and glaucomatous visual field (VF) progression in open-angle glaucoma (OAG), including primary OAG and normal tension glaucoma. The subjects of the study were patients undergoing treatment for OAG who had performed VF tests at least 10 times with a Humphrey field analyzer (SITA standard, C30-2 program). The VF progression was defined by a significantly negative MD slope (MD slope worsening) at the final VF test during the follow-up period. The relationship between the MD slope worsening and the consecutive deterioration of MD value were retrospectively analyzed. A total of 165 eyes of 165 patients were included in the analysis. Significant progression of VF defects was observed in 72 eyes of 72 patients (43.6%), while no significant progression was evident in 93 eyes of 93 patients (56.4%). There was significant relationship between the frequency of consecutive deterioration of MD value and MD slope worsening (P<0.0001, Cochran-Armitage trend test). A significant association was observed for MD slope worsening in the eyes with three (odds ratio: 2.1, P=0.0224) and four (odds ratio: 3.6, P=0.0008) consecutive deterioration of MD value in multiple logistic regression analysis, but no significant association in the eyes with two consecutive deterioration (odds ratio: 1.1, P=0.8282). The eyes with VF progression had significantly lower intraocular pressure reduction rate (P<0.01). This retrospective study has shown that three or more consecutive deterioration of MD value might be a predictor to future significant MD slope worsening in OAG.

  7. Involvement of genetic variants associated with primary open-angle glaucoma in pathogenic mechanisms and family history of glaucoma.

    PubMed

    Mabuchi, Fumihiko; Sakurada, Yoichi; Kashiwagi, Kenji; Yamagata, Zentaro; Iijima, Hiroyuki; Tsukahara, Shigeo

    2015-03-01

    To investigate the associations between the non-intraocular pressure (IOP)-related genetic variants (genetic variants associated with vulnerability of the optic nerve independent of IOP) and primary open-angle glaucoma (POAG), including normal-tension glaucoma (NTG) and high-tension glaucoma (HTG), and between the non-IOP-related genetic variants and a family history of glaucoma. Case-control study. Japanese patients with NTG (n = 213) and HTG (n = 212) and 191 control subjects were genotyped for 5 non-IOP-related genetic variants predisposing to POAG near the SRBD1, ELOVL5, CDKN2B/CDKN2B-AS1, SIX1/SIX6, and ATOH7 genes. The load of these genetic variants was compared between the control subjects and patients with NTG or HTG and between the POAG patients with and without a family history of glaucoma. The total number of POAG risk alleles and the product of the odds ratios (POAG risk) of these genetic variants were significantly larger (P < .0025) in patients with both NTG and HTG than in the control subjects, and were significantly larger (P = .0042 and P = .023, respectively) in POAG patients with a family history of glaucoma than in those without. As the number of relatives with glaucoma increased, the total number of risk alleles and the product of the odds ratios increased (P = .012 and P = .047, respectively). Non-IOP-related genetic variants contribute to the pathogenesis of HTG as well as NTG. A positive family history of glaucoma in cases of POAG is thought to reflect the influence of genetic variants predisposing to POAG. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Performance of the Angle Labor Pain Questionnaire During Initiation of Epidural Analgesia in Early Active Labor.

    PubMed

    Angle, Pamela J; Kurtz Landy, Christine; Djordjevic, Jasmine; Barrett, Jon; Kibbe, Alanna; Sriparamananthan, Saiena; Lee, Yuna; Hamata, Lydia; Zaki, Pearl; Kiss, Alex

    2016-12-01

    The Angle Labor Pain Questionnaire (A-LPQ) is a new, 22-item multidimensional psychometric questionnaire that measures the 5 most important dimensions of women's childbirth pain experiences using 5 subscales: The Enormity of the Pain, Fear/Anxiety, Uterine Contraction Pain, Birthing Pain, and Back Pain/Long Haul. Previous work showed that the A-LPQ has overall good psychometric properties and performance during early active labor in women without pain relief. The current study assessed the tool's sensitivity to change during initiation of labor epidural analgesia with the standardized response mean (SRM, primary outcome). Two versions of the A-LPQ were administered once, in each of 2 test sessions, by the same trained interviewer during early active labor. The sequence of administration was randomized (ie, standard question order version [Test 1] followed by mixed version [Test 2] or vice versa). Test 1 was completed before epidural insertion; Test 2 commenced 20 to 30 minutes after the test dose. Providers assessed/treated pain independently of the study. Sensitivity to change was assessed using SRMs, Cohen's d, and paired t tests. Overall pain intensity was concurrently examined using Numeric Rating Scale and the Verbal Rating Scale (VRS); coping was assessed with the Pain Mastery Scale. Changes in pain were measured with the Patient Global Impression of Change Scale. Internal consistency was assessed with Cronbach's α. Concurrent validity with other tools was assessed using Spearman's rank correlation coefficient. A total of 51 complete datasets were analyzed. Most women reported moderate (63%, 32/51) or severe (18%, 9/51) baseline pain on VRS scores during Test 1; 29% (15/51) reported mild pain, and 6% (3/51) reported moderate pain during Test 2. Approximately 90% (46/51) of women reported much or very much improved pain at the end of testing. Cronbach's α for A-LPQ summary scores was excellent (0.94) and ranged from 0.78 (acceptable) to 0.92 (excellent) for

  9. 24-Hour Efficacy and Ocular Surface Health with Preservative-Free Tafluprost Alone and in Conjunction with Preservative-Free Dorzolamide/Timolol Fixed Combination in Open-Angle Glaucoma Patients Insufficiently Controlled with Preserved Latanoprost Monotherapy.

    PubMed

    Konstas, Anastasios-Georgios; Boboridis, Konstadinos G; Kapis, Paraskevas; Marinopoulos, Konstantinos; Voudouragkaki, Irini C; Panayiotou, Dimitrios; Mikropoulos, Dimitrios G; Pagkalidou, Eirini; Haidich, Anna-Bettina; Katsanos, Andreas; Quaranta, Luciano

    2017-01-01

    The aim of the present study was to evaluate the 24-h efficacy, tolerability, and ocular surface health with preservative-free (PF) tafluprost and a PF triple drug regimen comprising tafluprost and dorzolamide/timolol fixed combination (DTFC) in open-angle glaucoma patients who were insufficiently controlled with preserved branded or generic latanoprost monotherapy and who exhibited signs or symptoms of ocular surface disease (OSD). Prospective, observer-masked, crossover, comparison. Eligible consecutive open-angle glaucoma patients were randomized to either PF tafluprost or the triple PF regimen for 3 months. They were then crossed over to the opposite therapy for another 3 months. At the end of the latanoprost run-in period and after each PF treatment period, patients underwent habitual 24-h intraocular pressure (IOP) monitoring with Goldmann tonometry in the sitting position (at 10:00, 14:00, 18:00, and 22:00) and Perkins tonometry in the supine position (at 02:00 and 06:00). Tolerability and selected ocular surface parameters were evaluated at baseline and the end of each treatment period. Forty-three open-angle glaucoma patients completed the trial. Mean 24-h IOP on preserved latanoprost was 22.2 ± 3.9 mmHg. Compared with latanoprost monotherapy, PF tafluprost obtained a greater reduction in mean, peak, and fluctuation of 24-h IOP including the 02:00 and 06:00 time points (P < 0.05). With the exception of 24-h fluctuation, the triple PF regimen provided significantly lower IOP parameters than latanoprost or PF tafluprost (P < 0.001). Finally, PF tafluprost therapy displayed significantly improved tear film break-up times (6.7 vs 6.0 s), corneal staining (1.3 vs 2.2), and Schirmer I test results (9.1 vs 8.2 mm) compared with the preserved latanoprost baseline (all P < 0.01). The triple PF regimen demonstrated similar tear film break-up times (6.1 vs 6.0 s) and Schirmer I test results (8.2 vs 8.2 mm) to latanoprost, but revealed a significant

  10. Early Clinical Features of Pseudoexfoliation Syndrome in Anterior Segment and Gonioscopy Examination.

    PubMed

    Gür Güngör, Sirel; Bayer, Atilla; Akman, Ahmet; Asena, Leyla

    2017-01-01

    To determine the early signs of pseudoexfoliation (PEX) in fellow eyes of cases with unilateral PEX. Fellow eyes of 34 cases with unilateral PEX were evaluated by slit-lamp and gonioscopy. Findings associated with PEX were recorded. Mean age was 67.8±8.1 years (range 55-86 years). Twenty-five patients (73.5%) had pigmentation in the inferior angle and 23 patients (67.6%) had Sampaolesi's line located on the inferior angle in fellow eyes. The other most common findings were loss of peripupillary ruff in 10 patients (29.4%) and pigment dispersion following pupil dilation in 14 patients (41.1%). Pigmentation in the inferior angle and Sampaolesi's line on the inferior angle seem to be the most common early findings associated with PEX. Special attention should be paid to these findings in cases with ocular hypertension for proper management.

  11. Setting the magic angle for fast magic-angle spinning probes.

    PubMed

    Penzel, Susanne; Smith, Albert A; Ernst, Matthias; Meier, Beat H

    2018-06-15

    Fast magic-angle spinning, coupled with 1 H detection is a powerful method to improve spectral resolution and signal to noise in solid-state NMR spectra. Commercial probes now provide spinning frequencies in excess of 100 kHz. Then, one has sufficient resolution in the 1 H dimension to directly detect protons, which have a gyromagnetic ratio approximately four times larger than 13 C spins. However, the gains in sensitivity can quickly be lost if the rotation angle is not set precisely. The most common method of magic-angle calibration is to optimize the number of rotary echoes, or sideband intensity, observed on a sample of KBr. However, this typically uses relatively low spinning frequencies, where the spinning of fast-MAS probes is often unstable, and detection on the 13 C channel, for which fast-MAS probes are typically not optimized. Therefore, we compare the KBr-based optimization of the magic angle with two alternative approaches: optimization of the splitting observed in 13 C-labeled glycine-ethylester on the carbonyl due to the Cα-C' J-coupling, or optimization of the H-N J-coupling spin echo in the protein sample itself. The latter method has the particular advantage that no separate sample is necessary for the magic-angle optimization. Copyright © 2018. Published by Elsevier Inc.

  12. Development of a prototype Open-close positron emission tomography system

    NASA Astrophysics Data System (ADS)

    Yamamoto, Seiichi; Okumura, Satoshi; Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu; Toshito, Toshiyuki; Komori, Masataka; Ogata, Yoshimune; Kato, Katsuhiko; Hatazawa, Jun

    2015-08-01

    We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types of gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image guides were used to arrange the two scintillator blocks at 22.5° so that they can be arranged in a hexadecagonal shape with eight block detectors to simplify the reconstruction algorithm. The detector ring was divided into two halves to realize the open-mode and set on a mechanical stand with which the distance between the two parts can be manually changed. The spatial resolution in the close-mode was 2.4-mm FWHM, and the sensitivity was 1.7% at the center of the field-of-view. In both the close- and open-modes, we made sagittal (y-z plane) projection images between the two halved detector rings. We obtained reconstructed and projection images of 18F-NaF rat studies and proton-irradiated phantom images. These results indicate that our developed Open-close PET is useful for some applications such as proton therapy as well as other applications such as molecular imaging.

  13. Structurally colored films with superhydrophobicity and wide viewing angles based on bumpy melanin-like particles

    NASA Astrophysics Data System (ADS)

    Yi, Bo; Shen, Huifang

    2018-01-01

    Non-iridescent structural colors and lotus effect universally existing in the nature provide a great inspiration for artificially developing angle-independent and high hydrophobic structurally colored films. To this end, a facile strategy is put forward for achieving superhydrophobic structurally colored films with wide viewing angles and high visibility based on bumpy melanin-like polydopamine-coated polystyrene particles. Here, hierarchical and amorphous structures are assembled in a self-driven manner due to particles' protrusive surfaces. The superhydrophobicity of the structurally colored films, with water contact angle up to 151°, is realized by combining the hierarchical surface roughness with a dip-coating process of polydimethylsiloxane-hexane solution, while angle-independence revealed in the films is ascribed to amorphous arrays. In addition, benefited from an essential light-absorbing property and high refractive index of polydopamine, the visibility of as-prepared colored films is fundamentally enhanced. Moreover, the mechanical robustness of the films is considerably boosted by inletting 3-aminopropyltriethoxysilane. This fabrication strategy might provide an opportunity for promoting the open-air application of structurally colored coatings.

  14. A Different Angle on Perspective

    ERIC Educational Resources Information Center

    Frantz, Marc

    2012-01-01

    When a plane figure is photographed from different viewpoints, lengths and angles appear distorted. Hence it is often assumed that lengths, angles, protractors, and compasses have no place in projective geometry. Here we describe a sense in which certain angles are preserved by projective transformations. These angles can be constructed with…

  15. Comparison of Laser Scanning Diagnostic Devices for Early Glaucoma Detection.

    PubMed

    Schulze, Andreas; Lamparter, Julia; Pfeiffer, Norbert; Berisha, Fatmire; Schmidtmann, Irene; Hoffmann, Esther M

    2015-08-01

    To compare the diagnostic accuracy and to evaluate the correlation of optic nerve head and retinal nerve fiber layer thickness values between Fourier-Domain optical coherence tomography (FD-OCT), confocal scanning laser ophthalmoscopy (CSLO), and scanning laser polarimetry (SLP) for early glaucoma detection. Ninety-three patients with early open-angle glaucoma, 58 patients with ocular hypertension, and 60 healthy control subjects were included in this observational, cross-sectional study. All study participants underwent FD-OCT (RTVue-100), CSLO (HRT3), and SLP (GDx VCC) imaging of the optic nerve head and the retinal nerve fiber layer. Area under the receiver operating characteristic curves (AUROC) and Bland-Altman analysis were performed. The parameters with the highest diagnostic accuracy were found for FD-OCT cup-to-disc ratio (AUROC=0.841), for SLP NFI (AUROC=0.835), and for CSLO cup-to-disc ratio (AUROC=0.789). Diagnostic accuracy of the best CSLO and SLP parameter was similar (P=0.259). There was a small statistically significant difference between the best CSLO and FD-OCT parameters for differentiating between glaucoma and healthy eyes (P=0.047). FD-OCT and SLP have a similarly good diagnostic ability to distinguish between early glaucoma and healthy subjects. The diagnostic accuracy of CSLO was comparable with SLP and marginally lower compared with FD-OCT.

  16. The gonial angle stripper: an instrument for the treatment of prominent gonial angle.

    PubMed

    Kyutoku, S; Yanagida, A; Kusumoto, K; Ogawa, Y

    1994-12-01

    In the Orient, a prominent gonial angle, so-called benign masseteric hypertrophy, is rather common and considered unattractive. Therefore, its surgical correction is one of the most popular forms of facial skeletal contouring. For accurate and safe osteotomy of the mandibular angle region, a gonial angle stripper was specially invented. It has a small projection that will ease identification of the osteotomy line in a narrow operative field. The tool has been clinically used in eight patients to prove its usefulness, especially for a posteriorly developed mandibular angle.

  17. Crack-tip-opening angle measurements and crack tunneling under stable tearing in thin sheet 2024-T3 aluminum alloy

    NASA Technical Reports Server (NTRS)

    Dawicke, D. S.; Sutton, M. A.

    1993-01-01

    The stable tearing behavior of thin sheets 2024-T3 aluminum alloy was studied for middle crack tension specimens having initial cracks that were: flat cracks (low fatigue stress) and 45 degrees through-thickness slant cracks (high fatigue stress). The critical crack-tip-opening angle (CTOA) values during stable tearing were measured by two independent methods, optical microscopy and digital image correlation. Results from the two methods agreed well. The CTOA measurements and observations of the fracture surfaces showed that the initial stable tearing behavior of low and high fatigue stress tests is significantly different. The cracks in the low fatigue stress tests underwent a transition from flat-to-slant crack growth, during which the CTOA values were high and significant crack tunneling occurred. After crack growth equal to about the thickness, CTOA reached a constant value of 6 deg and after crack growth equal to about twice the thickness, crack tunneling stabilized. The initial high CTOA values, in the low fatigue crack tests, coincided with large three-dimensional crack front shape changes due to a variation in the through-thickness crack tip constraint. The cracks in the high fatigue stress tests reach the same constant CTOA value after crack growth equal to about the thickness, but produced only a slightly higher CTOA value during initial crack growth. For crack growth on the 45 degree slant, the crack front and local field variables are still highly three-dimensional. However, the constant CTOA values and stable crack front shape may allow the process to be approximated with two-dimensional models.

  18. John F. Kennedy Space Center's Wireless Hang Angle Instrumentation System

    NASA Technical Reports Server (NTRS)

    Kohler, Jeff

    2009-01-01

    The technology is a high-precision, wireless inclinometer. The system was designed for monitoring the suspension angle of the Orbiter vehicle during loading onto the Solid Rocket Boosters of the Space Shuttle. Originally, operators manually measured the alignment of the Orbiter with a hand-held inclinometer on a nonrigid surface. The measurement was open to interpretation by the loader. If the Orbiter is misaligned, it can crush ball joints and delay the loading while repairs are made. With this system, the Orbiter can be loaded without damage and without manual measurement.

  19. Aerodynamic Load Measurements and Opening Characteristics of Automatic Leading Edge Slats on a 45 deg Sweptback Wing at Transonic Speeds

    NASA Technical Reports Server (NTRS)

    Arabian, Donald D.; Runckel, Jack F.; Reid, Charles F, Jr.

    1961-01-01

    Measurements of the normal force and chord force were made on the slats of a sting-mounted wing-fuselage model through a Mach number range of 0.60 to 1.03 and at angles of attack from 0 to 20 deg at subsonic speeds and from 0 to 8 deg at Mach number 1.03. The 20-percent-chord tapered leading-edge slats extended from 25 to 95 percent of the semispan and consisted of five segments. The model wing had 45 deg sweep, an aspect ratio of 3.56, a taper ratio of 0.3, and NACA 64(06)AO07 airfoil sections. Slat forces and moments were determined for the slats in the almost-closed and open positions for spanwise extents of 35 to 95 percent and 46 to 95 percent of the semispan. The results of the investigation showed little change in the slat maximum force and moment coefficients with Mach number. The coefficients for the open and almost-closed slat positions had similar variations with angle of attack. The loads on the individual slat segments were found to increase toward the tip for moderate angles of attack and decrease toward the tip for high angles of attack. An analysis of the opening and closing characteristics of aerodynamically operated slats opening on a circular-arc path is included.

  20. Robotic surgery, video-assisted thoracic surgery, and open surgery for early stage lung cancer: comparison of costs and outcomes at a single institute.

    PubMed

    Novellis, Pierluigi; Bottoni, Edoardo; Voulaz, Emanuele; Cariboni, Umberto; Testori, Alberto; Bertolaccini, Luca; Giordano, Laura; Dieci, Elisa; Granato, Lorenzo; Vanni, Elena; Montorsi, Marco; Alloisio, Marco; Veronesi, Giulia

    2018-02-01

    Robotic surgery is increasingly used to resect lung cancer. However costs are high. We compared costs and outcomes for robotic surgery, video-assisted thoracic surgery (VATS), and open surgery, to treat non-small cell lung cancer (NSCLC). We retrospectively assessed 103 consecutive patients given lobectomy or segmentectomy for clinical stage I or II NSCLC. Three surgeons could choose VATS or open, the fourth could choose between all three techniques. Between-group differences were assessed by Fisher's exact, two-way analysis of variance (ANOVA), and Wilcoxon-Mann-Whitney test. P values <0.05 were considered significant. Twenty-three patients were treated by robot, 41 by VATS, and 39 by open surgery. Age, physical status, pulmonary function, comorbidities, stage, and perioperative complications did not differ between the groups. Pathological tumor size was greater in the open than VATS and robotic groups (P=0.025). Duration of surgery was 150, 191 and 116 minutes, by robotic, VATS and open approaches, respectively (P<0.001). Significantly more lymph node stations were removed (P<0.001), and median length of stay was shorter (4, 5 and 6 days, respectively; P<0.001) in the robotic than VATS and open groups. Estimated costs were 82%, 68% and 69%, respectively, of the regional health service reimbursement for robotic, VATS and open approaches. Robotic surgery for early lung cancer was associated with shorter stay and more extensive lymph node dissection than VATS and open surgery. Duration of surgery was shorter for robotic than VATS. Although the cost of robotic thoracic surgery is high, the hospital makes a profit.

  1. Angle-stable and compressed angle-stable locking for tibiotalocalcaneal arthrodesis with retrograde intramedullary nails. Biomechanical evaluation.

    PubMed

    Mückley, Thomas; Hoffmeier, Konrad; Klos, Kajetan; Petrovitch, Alexander; von Oldenburg, Geert; Hofmann, Gunther O

    2008-03-01

    Retrograde intramedullary nailing is an established procedure for tibiotalocalcaneal arthrodesis. The goal of this study was to evaluate the effects of angle-stable locking or compressed angle-stable locking on the initial stability of the nails and on the behavior of the constructs under cyclic loading conditions. Tibiotalocalcaneal arthrodesis was performed in fifteen third-generation synthetic bones and twenty-four fresh-frozen cadaver legs with use of retrograde intramedullary nailing with three different locking modes: a Stryker nail with compressed angle-stable locking, a Stryker nail with angle-stable locking, and a statically locked Biomet nail. Analyses were performed of the initial stability of the specimens (range of motion) and the laxity of the constructs (neutral zone) in dorsiflexion/plantar flexion, varus/valgus, and external rotation/internal rotation. Cyclic testing up to 100,000 cycles was also performed. The range of motion and the neutral zone in dorsiflexion/plantar flexion at specific cycle increments were determined. In both bone models, the intramedullary nails with compressed angle-stable locking and those with angle-stable locking were significantly superior, in terms of a smaller range of motion and neutral zone, to the statically locked nails. The compressed angle-stable nails were superior to the angle-stable nails only in the synthetic bone model, in external/internal rotation. Cyclic testing showed the nails with angle-stable locking and those with compressed angle-stable locking to have greater stability in both models. In the synthetic bone model, compressed angle-stable locking was significantly better than angle-stable locking; in the cadaver bone model, there was no significant difference between these two locking modes. During cyclic testing, five statically locked nails in the cadaver bone model failed, whereas one nail with angle-stable locking and one with compressed angle-stable locking failed. Regardless of the bone model

  2. Survival and Growth of Cottonwood Clones After Angle Planting and Base Angle Treatments

    Treesearch

    W.K. Randall; Harvey E. Kennedy

    1976-01-01

    Presently, commercial cottonwood plantations in the lower Mississippi Valley are established using vertically planted, unrooted cuttings with a flat (90°) base. Neither survival nor first-year growth of a group of six Stoneville clones was improved by angle planting or cutting base angles diagonally. For one clone, survival was significantly better when base angle was...

  3. Experimental study of the possibility of reducing the resistance and unevenness of output field of velocities in flat diffuser channels with large opening angles

    NASA Astrophysics Data System (ADS)

    Dmitriev, S. S.; Vasil'ev, K. E.; Mokhamed, S. M. S. O.; Gusev, A. A.; Barbashin, A. V.

    2017-11-01

    In modern combined cycle gas turbines (CCGT), when designing the reducers from the output diffuser of a gas turbine to a boiler-utilizer, wide-angle diffusers are used, in which practically from the input a flow separation and transition to jet stream regime occurs. In such channels, the energy loss in the field of velocities sharply rise and the field of velocities in the output from them is characterized by considerable unevenness that worsens the heat transfer process in the first by motion tube bundles of the boiler-utilizer. The results of experimental research of the method for reducing the energy loss and alignment of the field of velocities at the output from a flat asymmetrical diffuser channel with one deflecting wall with the opening angle of 40° by means of placing inside the channel the flat plate parallel to the deflecting wall are presented in the paper. It is revealed that, at this placement of the plate in the channel, it has a chance to reduce the energy loss by 20%, considerably align the output field of velocities, and decrease the dynamic loads on the walls in the output cross-section. The studied method of resistance reduction and alignment of the fields of velocities in the flat diffuser channels was used for optimization of the reducer from the output diffuser of the gas turbine to the boiler-utilizer of CCGT of PGU-450T type of Kaliningrad Thermal Power Plant-2. The obtained results are evidence that the configuration of the reducer installed in the PGU-450T of Kaliningrad Thermal Power Plant-2 is not optimal. It follows also from the obtained data that working-off the reducer should be necessarily conducted by the test results of the channel consisting of the model of reducer with the model of boiler-utilizer installed behind it. Application of the method of alignment of output field of velocities and reducing the resistance in the wide-angle diffusers investigated in the work made it possible—when using the known model of diffusion

  4. The Primary open-angle glaucoma gene WDR36 functions in ribosomal RNA processing and interacts with the p53 stress–response pathway

    PubMed Central

    Skarie, Jonathan M.; Link, Brian A.

    2008-01-01

    Primary open-angle glaucoma (POAG) is a genetically complex neuropathy that affects retinal ganglion cells and is a leading cause of blindness worldwide. WDR36, a gene of unknown function, was recently identified as causative for POAG at locus GLC1G. Subsequent studies found disease-associated variants in control populations, leaving the role of WDR36 in this disease unclear. To address this issue, we determined the function of WDR36. We studied Wdr36 in zebrafish and found it is the functional homolog of yeast Utp21. Utp21 is cell essential and functions in the nucleolar processing of 18S rRNA, which is required for ribosome biogenesis. Evidence for functional homology comes from sequence alignment, ubiquitous expression, sub-cellular localization to the nucleolus and loss-of-function phenotypes that include defects in 18S rRNA processing and abnormal nucleolar morphology. Additionally, we show that loss of Wdr36 function leads to an activation of the p53 stress–response pathway, suggesting that co-inheritance of defects in p53 pathway genes may influence the impact of WDR36 variants on POAG. Although these results overall do not provide evidence for or against a role of WDR36 in POAG, they do provide important baseline information for future studies. PMID:18469340

  5. Numerical investigation of the early flight phase in ski-jumping.

    PubMed

    Gardan, N; Schneider, A; Polidori, G; Trenchard, H; Seigneur, J M; Beaumont, F; Fourchet, F; Taiar, R

    2017-07-05

    The purpose of this study is to develop a numerical methodology based on real data from wind tunnel experiments to investigate the effect of the ski jumper's posture and speed on aerodynamic forces in a wide range of angles of attack. To improve our knowledge of the aerodynamic behavior of the ski jumper and his equipment during the early flight phase of the ski jump, we applied CFD methodology to evaluate the influence of angle of attack (α=14°, 21.5°, 29°, 36.5° and 44°) and speed (u=23, 26 and 29m/s) on aerodynamic forces in the situation of stable attitude of the ski jumper's body and skis. The standard k-ω turbulence model was used to investigate both the influence of the ski jumper's posture and speed on aerodynamic performance during the early flight phase. Numerical results show that the ski jumper's speed has very little impact on the lift and drag coefficients. Conversely, the lift and drag forces acting on the ski jumper's body during the early flight phase of the jump are strongly influenced by the variations of the angle of attack. The present results suggest that the greater the ski jumper's angle of inclination, with respect to the relative flow, the greater the pressure difference between the lower and upper parts of the skier. Further studies will focus on the dependency of the parameters with both the angle of attack α and the body-ski angle β as control variables. It will be possible to test and optimize different ski jumping styles in different ski jumping hills and investigate different environmental conditions such as temperature, altitude or crosswinds. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Angle-recession glaucoma: long-term clinical outcomes over a 10-year period in traumatic microhyphema.

    PubMed

    Ng, Danny Siu-Chun; Ching, Ruby Hok-Ying; Chan, Clement Wai-Nang

    2015-02-01

    This study aims to determine the incidence of angle recession and glaucoma after traumatic microhyphema. Records of all patients treated for traumatic hyphema or microhyphema admitted to a district hospital throughout a 10-year period were retrospectively reviewed. Patients with open-globe injury were excluded. The following clinical features were recorded during patients' initial presentation and follow-up visits: Snellen visual acuity, examination with slit-lamp biomicroscopy, intraocular pressure (IOP), dilated fundoscopic examination, gonioscopic examination and treatment. For patients with IOP > 21 mmHg and requiring glaucoma medications, visual field tests were performed. A total of 97 patients met the study criteria, of which 62 had microhyphema and 35 had gross hyphema. Among the traumatic microhyphema patients, 47 (75.8 %) had angle recession and 4 (6.5 %) had glaucoma with mean follow-up of 49 months (range 6-98 months). A statistically significant association was found between angle recession greater than 180° and the occurrence of glaucoma (p < 0.01). No statistically significant differences were found between groups of patients with microhyphema or gross hyphema regarding the incidence of angle recession and glaucoma. The complications of angle recession and glaucoma in patients after traumatic microhyphema appear similar to those found in patients after gross hyphema.

  7. Measurement of surface tension and viscosity by open capillary techniques

    DOEpatents

    Rye,Robert R. , Yost,Frederick G.

    1998-01-01

    An open-channel capillary is provided, having preferably a v-shaped groove in a flat wettable surface. The groove has timing marks and a source marker in which the specimen to be tested is deposited. The time of passage between the timing marks is recorded, and the ratio of surface tension .gamma. to viscosity .mu. is determined from the equation given below: ##EQU1## where h.sub.0 is the groove depth, .alpha. is the groove angle, .theta. is the liquid/solid contact angle, and t is the flow time. It has been shown by the

  8. Stationary Digital Tomosynthesis System for Early Detection of Breast Tumors

    DTIC Science & Technology

    2012-05-01

    Vol. 5745. 2005. 14. Y. Zhang, et al., A comparative study of limited-angle cone-beam reconstruction methods 505 for breast tomosynthesis. Med...opening angl em integratio designed line nia Dimension determine the try calibration th the detector ain is sent fro between XC urce not fou here...screening mammography. AJR, 2007. 189: p. 616. 12. P. Baldelli, et al., A prototype of a quasi-monochromatic system for mammography applications . Phys

  9. A target field design of open multi-purpose RF coil for musculoskeletal MR imaging at 3T.

    PubMed

    Gao, Fei; Zhang, Rui; Zhou, Diange; Wang, Xiaoying; Huang, Kefu; Zhang, Jue

    2016-10-01

    Musculoskeletal MR imaging under multi-angle situations plays an increasingly important role in assessing joint and muscle tissues system. However, there are still limitations due to the closed structures of most conventional RF coils. In this study, a time-harmonic target-field method was employed to design open multi-purpose coil (OMC) for multi-angle musculoskeletal MR imaging. The phantom imaging results suggested that the proposed OMC could achieve homogeneously distributed magnetic field and high signal-to-noise ratio (SNR) of 239.04±0.83 in the region of interest (ROI). The maximum temperature in the heating hazard test was 16°C lower than the standard regulation, which indicated the security of the designed OMC. Furthermore, to demonstrate the effectiveness of the proposed OMC for musculoskeletal MR imaging, especially for multi-angle imaging, a healthy volunteer was examined for MR imaging of elbow, ankle and knee using OMC. The in vivo imaging results showed that the proposed OMC is effective for MR imaging of musculoskeletal tissues at different body parts, with satisfied B1 field homogeneity and SNR. Moreover, the open structure of the OMC could provide a large joint movement region. The proposed open multi-purpose coil is feasible for musculoskeletal MR imaging, and potentially, it is more suitable for the evaluation of musculoskeletal tissues under multi-angle conditions. Copyright © 2016. Published by Elsevier Inc.

  10. Photoelectric angle converter

    NASA Astrophysics Data System (ADS)

    Podzharenko, Volodymyr A.; Kulakov, Pavlo I.

    2001-06-01

    The photo-electric angle transmitter of rotation is offered, at which the output voltage is linear function of entering magnitude. In a transmitter the linear phototransducer is used on the basis of pair photo diode -- operating amplifier, which output voltage is linear function of the area of an illuminated photosensitive stratum, and modulator of a light stream of the special shape, which ensures a linear dependence of this area from an angle of rotation. The transmitter has good frequent properties and can be used for dynamic measurements of an angular velocity and angle of rotation, in systems of exact drives and systems of autocontrol.

  11. Early lens extraction with intraocular lens implantation for the treatment of primary angle closure glaucoma: an economic evaluation based on data from the EAGLE trial

    PubMed Central

    Javanbakht, Mehdi; Azuara-Blanco, Augusto; Burr, Jennifer M; Ramsay, Craig; Cooper, David; Cochran, Claire; Norrie, John; Scotland, Graham

    2017-01-01

    Objective To investigate the cost-effectiveness of early lens extraction with intraocular lens implantation for the treatment of primary angle closure glaucoma (PACG) compared to standard care. Design Cost-effectiveness analysis alongside a multicentre pragmatic two-arm randomised controlled trial. Patients were followed-up for 36 months, and data on health service usage and health state utility were collected and analysed within the trial time horizon. A Markov model was developed to extrapolate the results over a 5-year and 10-year time horizon. Setting 22 hospital eye services in the UK. Population Males and females aged 50 years or over with newly diagnosed PACG or primary angle closure (PAC). Interventions Lens extraction compared to standard care (ie, laser iridotomy followed by medical therapy and glaucoma surgery). Outcome measures Costs of primary and secondary healthcare usage (UK NHS perspective), quality-adjusted life years (QALYs) and the incremental cost-effectiveness ratio (ICER) for lens extraction versus standard care. Results The mean age of participants was 67.5 (8.42), 57.5% were women, 44.6% had both eyes eligible, 1.4% were of Asian ethnicity and 35.4% had PAC. The mean health service costs were higher in patients randomised to lens extraction: £2467 vs £1486. The mean adjusted QALYs were also higher with early lens extraction: 2.602 vs 2.533. The ICER for lens extraction versus standard care was £14 284 per QALY gained at three years. Modelling suggests that the ICER may drop to £7090 per QALY gained by 5 years and that lens extraction may be cost saving by 10 years. Our results are generally robust to changes in the key input parameters and assumptions. Conclusions We find that lens extraction has a 67–89% chance of being cost-effective at 3 years and that it may be cost saving by 10 years. Trial registration number ISRCTN44464607; Results. PMID:28087548

  12. The Emergence of Open-Source Software in North America

    ERIC Educational Resources Information Center

    Pan, Guohua; Bonk, Curtis J.

    2007-01-01

    Unlike conventional models of software development, the open source model is based on the collaborative efforts of users who are also co-developers of the software. Interest in open source software has grown exponentially in recent years. A "Google" search for the phrase open source in early 2005 returned 28.8 million webpage hits, while…

  13. A Taxonomy of Massive Open Online Courses

    ERIC Educational Resources Information Center

    Pilli, Olga; Admiraal, Wilfried

    2016-01-01

    Massive Open Online Courses (MOOCs) as a new approach to distance education, which originated from the open education resources (OER) movement, are becoming widespread throughout the world. Over time, early versions of cMOOCs have undergone changes in terms of use, name and structure. In their short life, MOOCs have been categorized into different…

  14. Radiology of adolescent slipped capital femoral epiphysis: measurement of epiphyseal angles and diagnosis.

    PubMed

    Gekeler, Jörg

    2007-10-01

    AIMS OF DIAGNOSTIC RADIOGRAPHY: Visualization of the proximal femur in two clearly defined projections. Radiologic and morphological diagnosis of slipped capital femoral epiphysis. Evaluation of the stability of the femoral epiphysis: chronic slippage or acute interruption of continuity between the femoral epiphysis and the femoral neck metaphysis. Radiometric measurement of the spatial deformity of the femoral epiphysis. Measurement of the projected epiphyseal angle on the radiograph as the basis for possible conversion into anatomically correct angles at the proximal femur. Preoperative planning of therapeutic surgical procedures. Idiopathic hip pain in the growing child or adolescent. Referred pain to the knee or thigh. Unusual gait pattern with external rotation deformity of the leg, limping that favors one leg or limping due to leg length discrepancy. Abnormal sonography, CT or MRI findings. Eventful history including minor injury or genuine trauma. Symptoms and uncommon physical constitution: obesity, exceptional longitudinal growth of the extremities, and absence of secondary sex characteristics. Indications for Radiographic Imaging of the Hip Joint in Two Planes None. Standard positioning of the patient or the affected extremity. First standard radiograph: proximal femur in anteroposterior projection. Position of the leg with the patella directed anteriorly. Contraction of the external rotators at the hip joint is compensated by elevation of the hip until the leg is in the neutral position. Second standard radiograph: axial view of the proximal femur in anteroposterior projection. Leg flexed to 90 degrees at the hip and in 45 degrees abduction. Thigh position parallel to the longitudinal axis of the table (zero rotation). Early signs of incipient or imminent femoral epiphyseolysis: --Disintegration, widening and blurred margins of the epiphyseal plate. --Increasing loss of height of the femoral epiphysis due to incipient dislocation. --The tangent to the

  15. Evaluation of open graded friction course (OGFC) mixtures.

    DOT National Transportation Integrated Search

    2013-10-01

    Louisiana Department of Transportation and Development (LADOTD) began the development of Open-Graded : Friction Course (OGFC) mixtures in the late 1960s and early 1970s. In the early 1980s, a moratorium was : imposed on the use of OGFC mixtures due t...

  16. Is high myopia a risk factor for visual field progression or disk hemorrhage in primary open-angle glaucoma?

    PubMed

    Nitta, Koji; Sugiyama, Kazuhisa; Wajima, Ryotaro; Tachibana, Gaku

    2017-01-01

    The purpose of this study was to clarify differences between highly myopic and non-myopic primary open-angle glaucoma (POAG) patients, including normal-tension glaucoma patients. A total of 269 POAG patients were divided into two groups: patients with ≥26.5 mm of axial length (highly myopic group) and patients with <24.0 mm of axial length (non-myopic group). We analyzed 53 highly myopic and 93 non-myopic POAG patients. Age at first visit of the highly myopic group was significantly less than that of the non-myopic group ( P <0.0001). Baseline intraocular pressures (IOPs) showed no significant differences. Follow-up IOPs of the non-myopic group were significantly lower than those of the highly myopic group ( P =0.0009). According to the mean deviation definition of progression, the cumulative probability of non-progression of visual field (VF) loss was significantly greater in the highly myopic group (10-year survival rate, 73.7%±6.8%) than in the non-myopic group (10-year survival rate, 46.3%±5.8%; log-rank test, P =0.0142). The occurrence of disk hemorrhage (DH) in the non-myopic group (1.60±3.04) was significantly greater than that in the highly myopic group (0.93±2.13, P =0.0311). The cumulative probability of DH was significantly lower in the highly myopic group (10-year survival rate, 26.4%±5.4%) than in the non-myopic group (10-year survival rate, 47.2%±6.6%, P =0.0413). Highly myopic POAG is considered as a combination of myopic optic neuropathy and glaucomatous optic neuropathy (GON). If GON is predominant, it has frequent DH and more progressive VF loss. However, when the myopic optic neuropathy is predominant, it has less DH and less progressive VF loss.

  17. Early return to work following open carpal tunnel decompression in lamb freezing workers.

    PubMed

    Wyatt, M C; Veale, G A

    2008-08-01

    Carpal tunnel syndrome is common at the largest lamb processing plant in the world, especially in new lamb boners. The purpose of this study was to establish the incidence and whether expeditious return to work following open carpal tunnel decompression was possible. Two hundred patients with a neurophysiologically confirmed diagnosis underwent surgery between 2002 and 2006. One hundred and eighty-seven patients were assessed retrospectively and 13 prospectively. The incidence in new lamb boners was 10% in their first season. On average, workers commenced rehabilitation at 11 days post-operatively and full duties at 29 days post-operatively with minimal further time off taken. Ninety percent returned to their previous role. By 8 weeks in the prospective group visual analogue pain scores had improved from 8.75 to 2.0 (P<0.01) and Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) scores had improved from 140 points to 68 (P<0.01). Grip/pinch testing, static two-point discrimination scores and complication rates were comparable with previous studies. This study provides good evidence that coordinated, early rehabilitation and return to work is effective in a high-demand population.

  18. Dental and skeletal components of Class II open bite treatment with a modified Thurow appliance

    PubMed Central

    Jacob, Helder Baldi; dos Santos-Pinto, Ary; Buschang, Peter H.

    2014-01-01

    Introduction Due to the lack of studies that distinguish between dentoalveolar and basal changes caused by the Thurow appliance, this clinical study, carried out by the School of Dentistry - State University of São Paulo/Araraquara, aimed at assessing the dental and skeletal changes induced by modified Thurow appliance. Methods The sample included an experimental group comprising 13 subjects aged between 7 and 10 years old, with Class II malocclusion and anterior open bite, and a control group comprising 22 subjects similar in age, sex and mandibular plane angle. Maxillary/mandibular, horizontal/vertical, dental/skeletal movements (ANS, PNS, U1, U6, Co, Go, Pog, L1, L6) were assessed, based on 14 landmarks, 8 angles (S-N-ANS, SNA, PPA, S-N-Pog, SNB, MPA, PP/MPA, ANB) and 3 linear measures (N-Me, ANS-Me, S-Go). Results Treatment caused significantly greater angle decrease between the palatal and the mandibular plane of the experimental group, primarily due to an increase in the palatal plane angle. ANB, SNA and S-N-ANS angles significantly decreased more in patients from the experimental group. PNS was superiorly remodeled. Lower face height (ANS-Me) decreased in the experimental group and increased in the control group. Conclusions The modified Thurow appliance controlled vertical and horizontal displacements of the maxilla, rotated the maxilla and improved open bite malocclusion, decreasing lower facial height. PMID:24713556

  19. Sharper angle, higher risk? The effect of cutting angle on knee mechanics in invasion sport athletes.

    PubMed

    Schreurs, Mervin J; Benjaminse, Anne; Lemmink, Koen A P M

    2017-10-03

    Cutting is an important skill in team-sports, but unfortunately is also related to non-contact ACL injuries. The purpose was to examine knee kinetics and kinematics at different cutting angles. 13 males and 16 females performed cuts at different angles (45°, 90°, 135° and 180°) at maximum speed. 3D kinematics and kinetics were collected. To determine differences across cutting angles (45°, 90°, 135° and 180°) and sex (female, male), a 4×2 repeated measures ANOVA was conducted followed by post hoc comparisons (Bonferroni) with alpha level set at α≤0.05a priori. At all cutting angles, males showed greater knee flexion angles than females (p<0.01). Also, where males performed all cutting angles with no differences in the amount of knee flexion -42.53°±8.95°, females decreased their knee flexion angle from -40.6°±7.2° when cutting at 45° to -36.81°±9.10° when cutting at 90°, 135° and 180° (p<0.01). Knee flexion moment decreased for both sexes when cutting towards sharper angles (p<0.05). At 90°, 135° and 180°, males showed greater knee valgus moments than females. For both sexes, knee valgus moment increased towards the sharper cutting angles and then stabilized compared to the 45° cutting angle (p<0.01). Both females and males showed smaller vGRF when cutting to sharper angles (p<0.01). It can be concluded that different cutting angles demand different knee kinematics and kinetics. Sharper cutting angles place the knee more at risk. However, females and males handle this differently, which has implications for injury prevention. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Assessment of circumferential angle-closure by the iris-trabecular contact index with swept-source optical coherence tomography.

    PubMed

    Baskaran, Mani; Ho, Sue-Wei; Tun, Tin A; How, Alicia C; Perera, Shamira A; Friedman, David S; Aung, Tin

    2013-11-01

    To evaluate the diagnostic performance of the iris-trabecular contact (ITC) index, a measure of the degree of angle-closure, using swept-source optical coherence tomography (SSOCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan) in comparison with gonioscopy. Prospective observational study. A total of 108 normal subjects and 32 subjects with angle-closure. The SSOCT 3-dimensional angle scans, which obtain radial scans for the entire circumference of the angle, were performed under dark conditions and analyzed using customized software by a single examiner masked to the subjects' clinical details. The ITC index was calculated as a percentage of the angle that was closed on SSOCT images. First-order agreement coefficient (AC1) statistics and area under the receiver operating characteristic curve (AUC) analyses were performed for angle-closure on the basis of the ITC index in comparison with gonioscopy. Angle-closure on gonioscopy was defined as nonvisibility of posterior trabecular meshwork for at least 2 quadrants. Agreement of the ITC index with gonioscopically defined angle-closure was assessed using the AC1 statistic. Study subjects were predominantly Chinese (95.7%) and female (70.7%), with a mean age of 59.2 (standard deviation, 8.9) years. The median ITC index was 15.24% for gonioscopically open-angle eyes (n = 108) and 48.5% for closed-angle eyes (n = 32) (P = 0.0001). The agreement for angle-closure based on ITC index cutoffs (>35% and ≥50%) and gonioscopic angle-closure was 0.699 and 0.718, respectively. The AUC for angle-closure detection using the ITC index was 0.83 (95% confidence interval, 0.76-0.89), with an ITC index >35% having a sensitivity of 71.9% and specificity of 84.3%. The ITC index is a summary measure of the circumferential extent of angle-closure as imaged with SSOCT. The index had moderate agreement and good diagnostic performance for angle-closure with gonioscopy as the reference standard. Copyright © 2013 American Academy of

  1. Electron pitch angle distributions throughout the magnetosphere as observed on Ogo 5.

    NASA Technical Reports Server (NTRS)

    West, H. I., Jr.; Buck, R. M.; Walton, J. R.

    1973-01-01

    A survey of the equatorial pitch angle distributions of energetic electrons is provided for all local times out to radial distances of 20 earth radii on the night side of the earth and to the magnetopause on the day side of the earth. In much of the inner magnetosphere and in the outer magnetosphere on the day side of the earth, the normal loss cone distribution prevails. The effects of drift shell splitting - i.e., the appearance of pitch angle distributions with minimums at 90 deg, called butterfly distributions - become apparent in the early afternoon magnetosphere at extended distances, and the distribution is observed in to 5.5 earth radii in the nighttime magnetosphere. Inside about 9 earth radii the pitch angle effects are quite energy-dependent. Beyond about 9 earth radii in the premidnight magnetosphere during quiet times the butterfly distribution is often observed. It is shown that these electrons cannot survive a drift to dawn without being considerably modified. The role of substorm activity in modifying these distributions is identified.

  2. Long-term titrated IOP control with one, two, or three trabecular micro-bypass stents in open-angle glaucoma subjects on topical hypotensive medication: 42-month outcomes

    PubMed Central

    Erb, Carl; Carceller Guillamet, Amadeu; Fea, Antonio M; Voskanyan, Lilit; Giamporcaro, Jane Ellen; Hornbeak, Dana M

    2018-01-01

    Purpose Evaluate long-term outcomes after one, two, or three trabecular micro-bypass stents implanted in a standalone procedure in eyes with open-angle glaucoma taking ocular hypotensive medication. Patients and methods Prospective randomized ongoing study of 119 subjects (109 with 42-month follow-up) with open-angle glaucoma, preoperative intraocular pressure (IOP) 18–30 mmHg on one to three glaucoma medications, and unmedicated (post-washout) IOP 22–38 mmHg. Subjects were randomized to receive one (n=38), two (n=41), or three (n=40) iStent trabecular micro-bypass stents in a standalone procedure. Postoperatively, IOP was measured with medication and annually following washout. Data included IOP, medications, gonioscopy, pachymetry, visual field, visual acuity, adverse events, and slit-lamp and fundus examinations. Results Preoperative mean medicated IOP was 19.8±1.3 mmHg on 1.71 medications in one-stent eyes, 20.1±1.6 mmHg on 1.76 medications in two-stent eyes, and 20.4±1.8 mmHg on 1.53 medications in three-stent eyes. Post-washout IOP prior to stent implantation was 25.0±1.2, 25.0±1.7, and 25.1±1.9 mmHg in the three groups, respectively. Postoperatively, Month 42 medicated IOP was 15.0±2.8, 15.7±1.0 and 14.8±1.3 mmHg in the three groups, and post-washout IOP (Months 36–37) was 17.4±0.9, 15.8±1.1 and 14.2±1.5 mmHg, respectively. IOP reduction ≥20% without medication was achieved in 89%, 90%, and 92% of one-, two-, and three-stent eyes, respectively, at Month 12; and in 61%, 91%, and 91% of eyes, respectively, at Month 42. The need for additional medication remained consistent at Months 12 and 42 in multi-stent eyes (four two-stent eyes and three three-stent eyes at both time points), whereas it increased in single-stent eyes (four eyes at Month 12 versus 18 eyes at Month 42). Safety parameters were favorable in all groups. Conclusion The standalone implantation of either single or multiple iStent® device(s) produced safe, clinically

  3. Behavior of Tilted Angle Shear Connectors.

    PubMed

    Khorramian, Koosha; Maleki, Shervin; Shariati, Mahdi; Ramli Sulong, N H

    2015-01-01

    According to recent researches, angle shear connectors are appropriate to transfer longitudinal shear forces across the steel-concrete interface. Angle steel profile has been used in different positions as L-shaped or C-shaped shear connectors. The application of angle shear connectors in tilted positions is of interest in this study. This study investigates the behaviour of tilted-shaped angle shear connectors under monotonic loading using experimental push out tests. Eight push-out specimens are tested to investigate the effects of different angle parameters on the ultimate load capacity of connectors. Two different tilted angles of 112.5 and 135 degrees between the angle leg and steel beam are considered. In addition, angle sizes and lengths are varied. Two different failure modes were observed consisting of concrete crushing-splitting and connector fracture. By increasing the size of connector, the maximum load increased for most cases. In general, the 135 degrees tilted angle shear connectors have a higher strength and stiffness than the 112.5 degrees type.

  4. Acoustic Shielding for a Model Scale Counter-rotation Open Rotor

    NASA Technical Reports Server (NTRS)

    Stephens, David B.; Edmane, Envia

    2012-01-01

    The noise shielding benefit of installing an open rotor above a simplified wing or tail is explored experimentally. The test results provide both a benchmark data set for validating shielding prediction tools and an opportunity for a system level evaluation of the noise reduction potential of propulsion noise shielding by an airframe component. A short barrier near the open rotor was found to provide up to 8.5 dB of attenuation at some directivity angles, with tonal sound particularly well shielded. Predictions from two simple shielding theories were found to overestimate the shielding benefit.

  5. Topical ocular sodium 4-phenylbutyrate rescues glaucoma in a myocilin mouse model of primary open-angle glaucoma.

    PubMed

    Zode, Gulab S; Bugge, Kevin E; Mohan, Kabhilan; Grozdanic, Sinisa D; Peters, Joseph C; Koehn, Demelza R; Anderson, Michael G; Kardon, Randy H; Stone, Edwin M; Sheffield, Val C

    2012-03-01

    Mutations in the myocilin gene (MYOC) are the most common known genetic cause of primary open-angle glaucoma (POAG). The purpose of this study was to determine whether topical ocular sodium 4-phenylbutyrate (PBA) treatment rescues glaucoma phenotypes in a mouse model of myocilin-associated glaucoma (Tg-MYOC(Y437H) mice). Tg-MYOC(Y437H) mice were treated with PBA eye drops (n = 10) or sterile PBS (n = 8) twice daily for 5 months. Long-term safety and effectiveness of topical PBA (0.2%) on glaucoma phenotypes were examined by measuring intraocular pressure (IOP) and pattern ERG (PERG), performing slit lamp evaluation of the anterior chamber, analyzing histologic sections of the anterior segment, and comparing myocilin levels in the aqueous humor and trabecular meshwork of Tg-MYOC(Y437H) mice. Tg-MYOC(Y437H) mice developed elevated IOP at 3 months of age when compared with wild-type (WT) littermates (n = 24; P < 0.0001). Topical PBA did not alter IOP in WT mice. However, it significantly reduced elevated IOP in Tg-MYOC(Y437H) mice to the level of WT mice. Topical PBA-treated Tg-MYOC(Y437H) mice also preserved PERG amplitudes compared with vehicle-treated Tg-MYOC(Y437H) mice. No structural abnormalities were observed in the anterior chamber of PBA-treated WT and Tg-MYOC(Y437H) mice. Analysis of the myocilin in the aqueous humor and TM revealed that PBA significantly improved the secretion of myocilin and reduced myocilin accumulation as well as endoplasmic reticulum (ER) stress in the TM of Tg-MYOC(Y437H) mice. Furthermore, topical PBA reduced IOP elevated by induction of ER stress via tunicamycin injections in WT mice. Topical ocular PBA reduces glaucomatous phenotypes in Tg-MYOC(Y437H) mice, most likely by reducing myocilin accumulation and ER stress in the TM. Topical ocular PBA could become a novel treatment for POAG patients with myocilin mutations.

  6. Associations of sleep duration with open angle glaucoma in the Korea national health and nutrition examination survey

    PubMed Central

    Lee, Jin-Ah; Han, Kyungdo; Min, Jung Ah; Choi, Jin A

    2016-01-01

    Abstract The aim of this study is to investigate the relationship between sleep duration and glaucoma, stratified by obesity status. This study was conducted using data from the Korean National Health and Nutrition Examination Survey V 2010 to 2012. Open-angle glaucoma was diagnosed according to the International Society of Geographical and Epidemiological Ophthalmology criteria. Subjects were divided into subgroups based on those who were overweight (body mass index ≥25 kg/m2 or <25 kg/m2) or with abdominal obesity (based on waist circumference). Multiple logistic regression analysis was done to estimate the magnitude of the association between sleep duration (<7 h, 7–<9, or ≥9 hours) and prevalence of glaucoma in the total population and in the subgroups. Individuals who slept <5 hours per night had the highest prevalence of glaucoma (5.55 ± 1.09%), followed by those who slept ≥9 hours per night (4.56 ± 0.10%), and then by those who slept 5 to <6 hours per night (4.15 ± 0.68%), which revealed a U-shaped pattern (P for trend = 0.072). Among overweight individuals, subjects who slept <7 hours and those who slept ≥9 hours were significantly more likely to have glaucoma compared with subjects who slept 7 to <9 hours after adjusting for survey year, age, sex, smoking, drinking, exercise, education level, household income, hypertension, intraocular pressure, stress, and depression (odds ratio, 2.41; 95% confidence interval, 1.14–5.03). Unlike for overweight individuals, sleep duration in nonoverweight individuals was not statistically significantly associated with glaucoma. Our results reveal a U-shaped association between sleep duration and the prevalence of glaucoma. An effect of sleep duration on glaucoma was present in the subgroup of overweight patients. PMID:28033268

  7. Comparison of calcaneal fixation of a retrograde intramedullary nail with a fixed-angle spiral blade versus a fixed-angle screw.

    PubMed

    Klos, Kajetan; Gueorguiev, Boyko; Schwieger, Karsten; Fröber, Rosemarie; Brodt, Steffen; Hofmann, Gunther O; Windolf, Markus; Mückley, Thomas

    2009-12-01

    Retrograde intramedullary nailing is an established technique for tibiotalocalcaneal arthrodesis (TTCA). In poor bone stock (osteoporosis, neuroarthropathy), device fixation in the hindfoot remains a problem. Fixed-angle spiral-blade fixation of the nail in the calcaneus could be useful. In seven matched pairs of human below-knee specimens, bone mineral density (BMD) was determined, and TTCA was performed with an intramedullary nail (Synthes Hindfoot Arthrodesis Nail HAN Expert Nailing System), using a conventional screw plus a fixed-angle spiral blade versus a conventional screw plus a fixed-angle screw, in the calcaneus. The constructs were subjected to quasi-static loading (dorsiflexion/plantarflexion, varus/valgus, rotation) and to cyclic loading to failure. Parameters studied were construct neutral zone (NZ) and range of motion (ROM), and number of cycles to failure. With dorsiflexion/plantarflexion loading, the screw-plus-spiral-blade constructs had a significantly smaller ROM in the quasi-static test (p = 0.028) and early in the cyclic test (p = 0.02); differences in the other parameters were not significant. There was a significant correlation between BMD and cycles to failure for the two-screw constructs (r = 0.94; p = 0.002) and for the screw-plus-spiral-blade constructs (r = 0.86; p = 0.014). In TTCA with a HAN Expert Nailing System, the use of a calcaneal spiral blade can further reduce motion within the construct. This may be especially useful in poor bone stock. Results obtained in this study could be used to guide the operating surgeon's TTCA strategy.

  8. An Exploratory Investigation of the Role of Openness in Relationship Quality among Emerging Adult Chinese Couples

    PubMed Central

    Zhou, Yixin; Wang, Kexin; Chen, Shuang; Zhang, Jianxin; Zhou, Mingjie

    2017-01-01

    This study tested emerging adult couples’ openness and its fit effect on their romantic relationship quality using quadratic polynomial regression and response surface analysis. Participants were 260 emerging adult dyads. Both dyads’ openness and relationship quality were measured. The result showed that (1) female and male openness contribute differently to relationship quality; (2) couples with similar high openness could experience better relationship quality than those with similar low openness traits; and (3) when dyadic openness is dissimilar, it is better to be either relatively high or relatively low than to be moderate. These findings highlight the role of openness in emerging adults’ romantic relationships from a dyadic angle. PMID:28360875

  9. Assessment of satellite retrieval algorithms for chlorophyll-a concentration under high solar zenith angle

    NASA Astrophysics Data System (ADS)

    Li, Hao; He, Xianqiang; Bai, Yan; Chen, Xiaoyan; Gong, Fang; Zhu, Qiankun; Hu, Zifeng

    2016-10-01

    Numerous empirical algorithms have been operationally used to retrieve the global ocean chlorophyll-a concentration (Chla) from ocean color satellite data, e.g., the OC4V4 algorithm for SeaWiFS and OC3M for MODIS. However, the algorithms have been established and validated based on the in situ data mainly measured under low to moderate solar zenith angle (<70°). Currently, with the development of the geostationary satellite ocean color remote sensing which observes from early morning to later afternoon, it is necessary to know whether the empirical Chla algorithms could be applied to high solar zenith angle. In this study, the performances of seven widely-used Chla algorithms under high solar zenith angles, i.e., OC2, OC3M, OC3V, OC4V4, CLARK, OCI, and YOC algorithms, were evaluated using the NOMAD global in situ ocean color dataset. The results showed that the performances of all the seven algorithms decreased significantly under high solar zenith angles as compared to those under low-moderate solar zenith angles. For instance, for the OC4V4 algorithm, the relative percent difference (RPD) and root-mean-square error (RMSE) were 13.78% and 1.66 μg/l for the whole dataset, and 3.95% and 1.49 μg/l for the solar zenith angles ranged from 30° to 40°, respectively. However, the RPD and RMSE increased to 30.45% and 6.10μg/l for solar zenith angle larger than 70°.

  10. A platform for dynamic simulation and control of movement based on OpenSim and MATLAB

    PubMed Central

    Mansouri, Misagh; Reinbolt, Jeffrey A.

    2013-01-01

    Numerical simulations play an important role in solving complex engineering problems and have the potential to revolutionize medical decision making and treatment strategies. In this paper, we combine the rapid model-based design, control systems and powerful numerical method strengths of MATLAB/Simulink with the simulation and human movement dynamics strengths of OpenSim by developing a new interface between the two software tools. OpenSim is integrated with Simulink using the MATLAB S-function mechanism, and the interface is demonstrated using both open-loop and closed-loop control systems. While the open-loop system uses MATLAB/Simulink to separately reproduce the OpenSim Forward Dynamics Tool, the closed-loop system adds the unique feature of feedback control to OpenSim, which is necessary for most human movement simulations. An arm model example was successfully used in both open-loop and closed-loop cases. For the open-loop case, the simulation reproduced results from the OpenSim Forward Dynamics Tool with root mean square (RMS) differences of 0.03° for the shoulder elevation angle and 0.06° for the elbow flexion angle. MATLAB’s variable step-size integrator reduced the time required to generate the forward dynamic simulation from 7.1 s (OpenSim) to 2.9 s (MATLAB). For the closed-loop case, a proportional–integral–derivative controller was used to successfully balance a pole on model’s hand despite random force disturbances on the pole. The new interface presented here not only integrates the OpenSim and MATLAB/Simulink software tools, but also will allow neuroscientists, physiologists, biomechanists, and physical therapists to adapt and generate new solutions as treatments for musculoskeletal conditions. PMID:22464351

  11. Phase III Early Restoration Meeting - Corpus Christi, TX | NOAA Gulf Spill

    Science.gov Websites

    Areas Alabama Florida Louisiana Mississippi Texas Region-wide Open Ocean Data Media & News programmatic approach to early restoration planning for Phase III and future early restoration plans. Open

  12. Mechanical strength assessment of a drilled hole in the contralateral cortex at the end of the open wedge for high tibial osteotomy.

    PubMed

    Diffo Kaze, Arnaud; Maas, Stefan; Hoffmann, Alexander; Pape, Dietrich

    2017-12-01

    This study aimed to investigate, by means of finite element analysis, the effect of a drill hole at the end of a horizontal osteotomy to reduce the risk of lateral cortex fracture while performing an opening wedge high tibial osteotomy (OWHTO). The question was whether drilling a hole relieves stress and increases the maximum correction angle without fracture of the lateral cortex depending on the ductility of the cortical bone. Two different types of osteotomy cuts were considered; one with a drill hole (diameter 5 mm) and the other without the hole. The drill holes were located about 20 mm distally to the tibial plateau and 6 mm medially to the lateral cortex, such that the minimal thickness of the contralateral cortical bone was 5 mm. Based on finite element calculations, two approaches were used to compare the two types of osteotomy cuts considered: (1) Assessing the static strength using local stresses following the idea of the FKM-guideline, subsequently referred to as the "FKM approach" and (2) limiting the total strain during the opening of the osteotomy wedge, subsequently referred to as "strain approach". A critical opening angle leading to crack initiation in the opposite lateral cortex was determined for each approach and was defined as comparative parameter. The relation to bone aging was investigated by considering the material parameters of cortical bones from young and old subjects. The maximum equivalent (von-Mises) stress was smaller for the cases with a drill hole at the end of the osteotomy cut. The critical angle was approximately 1.5 times higher for the specimens with a drill hole compared to those without. This corresponds to an average increase of 50%. The calculated critical angle for all approaches is below 5°. The critical angle depends on the used approach, on patient's age and assumed ductility of the cortical bone. Drilling a hole at the end of the osteotomy reduces the stresses in the lateral cortex and increases the critical

  13. Evaluation of a Wedge on a Force Balance as a Flow Angle Probe

    DTIC Science & Technology

    1975-02-01

    pitot rake attached to the Captive Trajectory System (CTS), and (3) measurement of flow angles in the same region with a probe attached to the CTS...localized pressures. Although it was the characteristics of supersonic flow which led to this conclusion, and even though the wedge design was based...vary the open area from near zero to 10 percent. Suction through the porous walls is used to maximize flow uniformity and to develop supersonic flow

  14. Does Lordotic Angle of Cage Determine Lumbar Lordosis in Lumbar Interbody Fusion?

    PubMed

    Hong, Taek-Ho; Cho, Kyu-Jung; Kim, Young-Tae; Park, Jae-Woo; Seo, Beom-Ho; Kim, Nak-Chul

    2017-07-01

    Retrospective, radiological analysis. To determine that 15° lordotic angle cages create higher lumbar lordosis in open transforaminal lumbar interbody fusion (TLIF) than 4° and 8° cages. Restoration of lumbar lordosis is important to obtain good outcome after lumbar fusion surgery. Various shapes and angles of cages in interbody fusion have been used; however, it is not proved that lordotic angle of cages determine lumbar lordosis. Sixty-seven patients were evaluated after TLIF using 15° cages and screw instrumentation. For comparison, TLIF using 4° lordotic angle cages in 65 patients and 8° cages in 49 patients were analyzed. Lumbar lordosis angles, segmental lordosis angles, disc height, and bony union rate were measured on the radiographs. The lumbar lordosis was 31.1° preoperatively, improved to 42.9° postoperatively, and decreased to 36.4° at the last follow-up in the 15° group. It was 35.8° before surgery, corrected to 41.5° after surgery, and changed to 33.6° at the last follow-up in the 4° group. In the 8° group, it was 32.7° preoperatively, improved to 39.1° postoperatively, and decreased to 34.5° at the last follow-up. These changes showed statistical significances (P < 0.001). The segmental lordosis at L4-5 was 6.6° before surgery, 13.1° after surgery, and 9.8° at the last follow-up in the 15° group. It was 6.9°, 9.5°, and 6.2° in the 4° group and 6.7°, 9.8°, and 8.1° in the 8° group, respectively (P < 0.001). The disc height restoration was better in the 15° group than in the 4° and 8° groups (P < 0.001). Bony union rate was not significant among the three groups (P = 0.087). The lordotic angle of the cages determined restoration of lumbar lordosis after TLIF. Cages with sufficient lordotic angle showed better restoration of lumbar lordosis and prevention of loss of correction. 4.

  15. Multicenter, Randomized, Controlled Study Comparing Tafluprost/Timolol Fixed Combination with Latanoprost/Timolol Fixed Combination in Primary Open-Angle Glaucoma and Ocular Hypertension.

    PubMed

    Suzuki, Katsuyoshi; Otsuka, Naomi; Hizaki, Hiroko; Hashimoto, Masayo; Kuwayama, Yasuaki

    2018-06-05

    This was the first exploratory randomized controlled study to compare the efficacy and safety of a preserved tafluprost/timolol fixed combination (TAF/TIM) with a preserved latanoprost/timolol fixed combination (LAT/TIM). This prospective, randomized, open-label study was conducted in Japanese patients with primary open-angle glaucoma, including normal-tension glaucoma or ocular hypertension. Following a 4-week LAT/TIM run-in period, eligible patients entered a 12-week treatment period, during which they received either LAT/TIM or TAF/TIM. The efficacy endpoint was the change in intraocular pressure (IOP) from baseline to week 12 and the safety endpoints included the changes from baseline to week 12 in superficial punctate keratopathy (SPK) score, tear breakup time (TBUT), and hyperemia score, as well as adverse events (AEs). At week 6, ocular symptoms were evaluated using a questionnaire. In total, 131 patients provided informed consent. Of these, 115 completed the run-in period and were assigned to receive TAF/TIM (n = 60) or LAT/TIM (n = 55). At week 12, there were no significant differences between the TAF/TIM and LAT/TIM groups in the change from baseline in trough IOP and IOP at 4-6 h after instillation. There were no significant differences between the two groups in the change from baseline to week 12 in SPK score, TBUT, and hyperemia score. However, only in the TAF/TIM group, the total SPK score and the inferior cornea SPK score were significantly lower at week 12 compared with baseline. Eye irritation and eye pain were significantly decreased in the TAF/TIM group compared with the LAT/TIM group. Two treatment-related AEs were reported in the TAF/TIM group (3.3%) and none in the LAT/TIM group, while no serious AEs were reported in either group. TAF/TIM is as effective as LAT/TIM in terms of IOP-reducing effect, with fewer ocular symptoms. TAF/TIM was associated with a significant improvement in SPK scores. UMIN Clinical Trials Registry Identifier

  16. Electric Dipole-Magnetic Dipole Polarizability and Anapole Magnetizability of Hydrogen Peroxide as Functions of the HOOH Dihedral Angle.

    PubMed

    Pelloni, S; Provasi, P F; Pagola, G I; Ferraro, M B; Lazzeretti, P

    2017-12-07

    The trace of tensors that account for chiroptical response of the H 2 O 2 molecule is a function of the HO-OH dihedral angle. It vanishes at 0° and 180°, due to the presence of molecular symmetry planes, but also for values in the range 90-100° of this angle, in which the molecule is unquestionably chiral. Such an atypical effect is caused by counterbalancing contributions of diagonal tensor components with nearly maximal magnitude but opposite sign, determined by electron flow in open or closed helical paths, and associated with induced electric and magnetic dipole moments and anapole moments. For values of dihedral angle external to the 90-100° interval, the helical paths become smaller in size, thus reducing the amount of cancellation among diagonal components. Shrinking of helical paths determines the appearance of extremum values of tensor traces approximately at 50° and 140° dihedral angles.

  17. Growth Angle - a Microscopic View

    NASA Technical Reports Server (NTRS)

    Mazurak, K.; Volz, M. P.; Croll, A.

    2017-01-01

    The growth angle that is formed between the side of the growing crystal and the melt meniscus is an important parameter in the detached Bridgman crystal growth method, where it determines the extent of the crystal-crucible wall gap, and in the Czochralski and float zone methods, where it influences the size and stability of the crystals. The growth angle is a non-equilibrium parameter, defined for the crystal growth process only. For a melt-crystal interface translating towards the crystal (melting), there is no specific angle defined between the melt and the sidewall of the solid. In this case, the corner at the triple line becomes rounded, and the angle between the sidewall and the incipience of meniscus can take a number of values, depending on the position of the triple line. In this work, a microscopic model is developed in which the fluid interacts with the solid surface through long range van der Waals or Casimir dispersive forces. This growth angle model is applied to Si and Ge and compared with the macroscopic approach of Herring. In the limit of a rounded corner with a large radius of curvature, the wetting of the melt on the crystal is defined by the contact angle. The proposed microscopic approach addresses the interesting issue of the transition from a contact angle to a growth angle as the radius of curvature decreases.

  18. Effects of enamel abrasion, salivary pellicle, and measurement angle on the optical assessment of dental erosion.

    PubMed

    Lussi, Adrian; Bossen, Anke; Höschele, Christoph; Beyeler, Barbara; Megert, Brigitte; Meier, Christoph; Rakhmatullina, Ekaterina

    2012-09-01

    The present study assessed the effects of abrasion, salivary proteins, and measurement angle on the quantification of early dental erosion by the analysis of reflection intensities from enamel. Enamel from 184 caries-free human molars was used for in vitro erosion in citric acid (pH 3.6). Abrasion of the eroded enamel resulted in a 6% to 14% increase in the specular reflection intensity compared to only eroded enamel, and the reflection increase depended on the erosion degree. Nevertheless, monitoring of early erosion by reflection analysis was possible even in the abraded eroded teeth. The presence of the salivary pellicle induced up to 22% higher reflection intensities due to the smoothing of the eroded enamel by the adhered proteins. However, this measurement artifact could be significantly minimized (p<0.05) by removing the pellicle layer with 3% NaOCl solution. Change of the measurement angles from 45 to 60 deg did not improve the sensitivity of the analysis at late erosion stages. The applicability of the method for monitoring the remineralization of eroded enamel remained unclear in a demineralization/remineralization cycling model of early dental erosion in vitro.

  19. Effects of enamel abrasion, salivary pellicle, and measurement angle on the optical assessment of dental erosion

    NASA Astrophysics Data System (ADS)

    Lussi, Adrian; Bossen, Anke; Höschele, Christoph; Beyeler, Barbara; Megert, Brigitte; Meier, Christoph; Rakhmatullina, Ekaterina

    2012-09-01

    The present study assessed the effects of abrasion, salivary proteins, and measurement angle on the quantification of early dental erosion by the analysis of reflection intensities from enamel. Enamel from 184 caries-free human molars was used for in vitro erosion in citric acid (pH 3.6). Abrasion of the eroded enamel resulted in a 6% to 14% increase in the specular reflection intensity compared to only eroded enamel, and the reflection increase depended on the erosion degree. Nevertheless, monitoring of early erosion by reflection analysis was possible even in the abraded eroded teeth. The presence of the salivary pellicle induced up to 22% higher reflection intensities due to the smoothing of the eroded enamel by the adhered proteins. However, this measurement artifact could be significantly minimized (p<0.05) by removing the pellicle layer with 3% NaOCl solution. Change of the measurement angles from 45 to 60 deg did not improve the sensitivity of the analysis at late erosion stages. The applicability of the method for monitoring the remineralization of eroded enamel remained unclear in a demineralization/remineralization cycling model of early dental erosion in vitro.

  20. Behavior of Tilted Angle Shear Connectors

    PubMed Central

    Khorramian, Koosha; Maleki, Shervin; Shariati, Mahdi; Ramli Sulong, N. H.

    2015-01-01

    According to recent researches, angle shear connectors are appropriate to transfer longitudinal shear forces across the steel-concrete interface. Angle steel profile has been used in different positions as L-shaped or C-shaped shear connectors. The application of angle shear connectors in tilted positions is of interest in this study. This study investigates the behaviour of tilted-shaped angle shear connectors under monotonic loading using experimental push out tests. Eight push-out specimens are tested to investigate the effects of different angle parameters on the ultimate load capacity of connectors. Two different tilted angles of 112.5 and 135 degrees between the angle leg and steel beam are considered. In addition, angle sizes and lengths are varied. Two different failure modes were observed consisting of concrete crushing-splitting and connector fracture. By increasing the size of connector, the maximum load increased for most cases. In general, the 135 degrees tilted angle shear connectors have a higher strength and stiffness than the 112.5 degrees type. PMID:26642193

  1. Phase III Early Restoration Meeting - Lake Charles, LA | NOAA Gulf Spill

    Science.gov Websites

    Areas Alabama Florida Louisiana Mississippi Texas Region-wide Open Ocean Data Media & News early restoration planning for Phase III and future early restoration plans. Open House: 5:30pm Public

  2. Dependence of diameters and oxygen saturation of retinal vessels on visual field damage and age in primary open-angle glaucoma.

    PubMed

    Ramm, Lisa; Jentsch, Susanne; Peters, Sven; Sauer, Lydia; Augsten, Regine; Hammer, Martin

    2016-05-01

    To investigate the interrelationship between the oxygen supply of the retina and its regulation with the severity of primary open-angle glaucoma (POAG). Central retinal artery (CRAE) and vein (CRVE) diameters and oxygen saturation of peripapillary retinal vessels in 41 patients suffering from POAG (64.1 ± 12.9 years) and 40 healthy volunteers (63.6 ± 14.1 years) were measured using the retinal vessel analyzer. All measures were taken before and during flicker light stimulation. The mean retinal nerve fiber layer thickness (RNFLT) was determined by OCT and the visual field mean defect (MD) was identified using perimetry. In glaucoma patients, CRAE (r = -0.48 p = 0.002) and CRVE (r = -0.394 p = 0.014) at baseline were inversely related to MD, while arterial and venous oxygen saturation showed no significant dependence on the severity of the damage. However, the flicker light-induced change in arterio-venous difference in oxygen saturation was correlated with the MD (r = 0.358 p = 0.027). The diameters of arteries and veins at baseline decreased with reduction of the mean RNFLT (arteries: r = 0.718 p < 0.001; veins: r = 0.685 p < 0.001). Vessel diameters showed a strong correlation with RNFLT and MD. This, as well as the reduction of stimulation-induced change in arterio-venous oxygen saturation difference with visual field loss, may be explained by a reduction of the retinal metabolic demand with progressive loss of neuronal tissue in glaucoma. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  3. The Optic Nerve Head in Primary Open-Angle Glaucoma Eyes With High Myopia: Characteristics and Association With Visual Field Defects.

    PubMed

    Chen, Li-Wei; Lan, Yu-Wen; Hsieh, Jui-Wen

    2016-06-01

    To evaluate the morphologic characteristics of optic neuropathy and its association with visual field (VF) defects in primary open-angle glaucoma (POAG) eyes with high myopia. In this cross-sectional study, we reviewed data from 375 Taiwanese patients (375 eyes) of POAG, ages 20 to 60 years. Optic disc photographs were used for planimetric measurements of morphologic variables. The myopic refraction was divided into high myopia (<-6.0 D) and nonhigh myopia (moderate myopia to hyperopia). The optic disc area was classified as moderate (1.59 to 2.85 mm), large, and small. Differences in characteristics between groups, correlations with the disc area, and factors associated with VF defects were determined. Of the 142 highly myopic eyes, 33 (23%) had a large disc, 26 (18%) had a small disc, and 55 (39%) had a tilted disc. Large discs had a higher cup-to-disc (C/D) area ratio and a higher tilt ratio; small discs had a smaller rim area and a lower tilt ratio (all P<0.05). Characteristics associated with high myopia included a smaller rim area, a higher C/D area ratio, and a lower tilt ratio (all P<0.001). In logistic regression, the refraction, the C/D area ratio, the rim area, and the tilt ratio (all P<0.05) were associated with VF defects. In Taiwanese individuals with POAG, our study found that tilted, large, or small discs were prevalent in highly myopic eyes. Of these characteristics, only the disc tilt and high myopia by itself were associated with the severity of glaucomatous optic neuropathy.

  4. View angle effect in LANDSAT imagery

    NASA Technical Reports Server (NTRS)

    Kaneko, T.; Engvall, J. L.

    1977-01-01

    The view angle effect in LANDSAT 2 imagery was investigated. The LANDSAT multispectral scanner scans over a range of view angles of -5.78 to 5.78 degrees. The view angle effect, which is caused by differing view angles, could be studied by comparing data collected at different view angles over a fixed location at a fixed time. Since such LANDSAT data is not available, consecutive day acquisition data were used as a substitute: they were collected over the same geographical location, acquired 24 hours apart, with a view angle change of 7 to 8 degrees at a latitude of 35 to 45 degrees. It is shown that there is approximately a 5% reduction in the average sensor response on the second-day acquisitions as compared with the first-day acquisitions, and that the view angle effect differs field to field and crop to crop. On false infrared color pictures the view angle effect causes changes primarily in brightness and to a lesser degree in color (hue and saturation). An implication is that caution must be taken when images with different view angles are combined for classification and a signature extension technique needs to take the view angle effect into account.

  5. Anterior Chamber Angle Measurements Using Schwalbe's Line with High Resolution Fourier-Domain Optical Coherence Tomography

    PubMed Central

    Qin, Bing; Francis, Brian A.; Li, Yan; Tang, Maolong; Zhang, Xinbo; Jiang, Chunhui; Cleary, Catherine; Huang, David

    2012-01-01

    Purpose To use Fourier-domain optical coherence tomography (OCT) to measure the angle opening distance at Schwalbe's line (AOD-SL) and determine its value in anterior chamber angle assessment. Methods Horizontal scans of the nasal and temporal anterior chamber angles in glaucoma subjects were performed by 830 nm wavelength Fourier-domain OCT. Images were graded by two ophthalmologists who assessed the visibility of Schwalbe’s line (SL), anterior limbus (AL), scleral spur (SS), and angle recess (AR). AOD-SL was measured with computer calipers. SL was manually identified by the termination of the corneal endothelium. Gonioscopy was used to classify anterior chamber angles according to a modified Shaffer system. Spearman's rho analysis was performed to assess correlation between AOD-SL and modified Shaffer grade. A cut-off value of AOD-SL for diagnosing occludable angles (modified Shaffer grade ≤1) was determined by receiver operating characteristic (ROC) analyses. Results Thirty-five glaucoma subjects (65 eyes) were enrolled. SL, AL, AR, and SS were visible by OCT in 97.7%, 99.2%, 87.3%, and 80.8% of eyes, respectively. Nasal and temporal AOD-SLs were 322.6 ± 200.2 µm and 341.4 ± 197.4 µm, respectively. Correlation coefficients between AOD-SL and modified Shaffer grade were 0.80 (nasal) and 0.81 (temporal). The diagnostic cut-off value of AOD-SL for occludable angles was 290 µm. The areas under the ROC curve, sensitivity, specificity values were 0.90, 0.80, 0.87 (nasal) and 0.90, 0.85, 0.77 (temporal). Conclusions The measurement of AOD-SL by Fourier-domain OCT is highly correlated with gonioscopy and may be a useful noncontact method of assessing angle closure risk. PMID:22827999

  6. High-angle faults control the geometry and morphology of the Corinth Rift

    NASA Astrophysics Data System (ADS)

    Bell, R. E.; Duclaux, G.; Nixon, C.; Gawthorpe, R.; McNeill, L. C.

    2016-12-01

    Slip along low-angle normal faults is mechanically difficult, and the existence of low angle detachment faults presents one of most important paradoxes in structural geology. Only a few examples of young continental rifts where low-angle faults may be a mechanism for accommodating strain have been described in the literature, and an important example is the Gulf of Corinth, central Greece. Here, microseismicity, the geometry of onshore faults and deep seismic reflection images have been used to argue for the presence of <30o dipping faults. However, new and reinterpreted data calls into question whether low-angle faults have been influential in controlling rift geometry. We seek to definitively test whether slip on a mature low-angle normal fault can reproduce the long-term geometry and morphology of the Corinth Rift, which involves i) significant uplift of the southern margin, ii) long-term uplift to subsidence ratios across south coast faults of 1 -2, and iii) a northern margin that does not undergo significant long-term uplift. We use PyLith, an open-source finite-element code for quasi-static viscoelastic simulations of crustal deformation and model the uplift and subsidence fields associated with the following fault geometries: i) planar faults with dips of 45-60° that sole onto a 10° detachment at a depth of 6 to 8 km, ii) 45-60° faults, which change to a dip angle of 25-45° at a depth of 3 km and continue to a brittle-ductile transition at 10 km and iii) planar faults which dip 45-60° to the brittle-ductile transition at a depth of 10 km. We show that models involving low-angle detachments, shallower than 8 km produce very minor coseismic uplift of the southern margin and post-seismic relaxation results in the southern margin experiencing net subsidence over many seismic cycles, incompatible with geological observations. Models involving planar faults produce long-term displacement fields involving uplifted southern margin with uplift to subsidence

  7. New insights into the genetics of primary open-angle glaucoma based on meta-analyses of intraocular pressure and optic disc characteristics

    PubMed Central

    Springelkamp, Henriët; Iglesias, Adriana I.; Mishra, Aniket; Höhn, René; Wojciechowski, Robert; Khawaja, Anthony P.; Nag, Abhishek; Wang, Ya Xing; Wang, Jie Jin; Cuellar-Partida, Gabriel; Gibson, Jane; Bailey, Jessica N. Cooke; Vithana, Eranga N.; Gharahkhani, Puya; Boutin, Thibaud; Ramdas, Wishal D.; Zeller, Tanja; Luben, Robert N.; Yonova-Doing, Ekaterina; Viswanathan, Ananth C.; Yazar, Seyhan; Cree, Angela J.; Haines, Jonathan L.; Koh, Jia Yu; Souzeau, Emmanuelle; Wilson, James F.; Amin, Najaf; Müller, Christian; Venturini, Cristina; Kearns, Lisa S.; Kang, Jae Hee; Tham, Yih Chung; Zhou, Tiger; van Leeuwen, Elisabeth M.; Nickels, Stefan; Sanfilippo, Paul; Liao, Jiemin; van der Linde, Herma; Zhao, Wanting; van Koolwijk, Leonieke M.E.; Zheng, Li; Rivadeneira, Fernando; Baskaran, Mani; van der Lee, Sven J.; Perera, Shamira; de Jong, Paulus T.V.M.; Oostra, Ben A.; Uitterlinden, André G.; Fan, Qiao; Hofman, Albert; Tai, E-Shyong; Vingerling, Johannes R.; Sim, Xueling; Wolfs, Roger C.W.; Teo, Yik Ying; Lemij, Hans G.; Khor, Chiea Chuen; Willemsen, Rob; Lackner, Karl J.; Aung, Tin; Jansonius, Nomdo M.; Montgomery, Grant; Wild, Philipp S.; Young, Terri L.; Burdon, Kathryn P.; Hysi, Pirro G.; Pasquale, Louis R.; Wong, Tien Yin; Klaver, Caroline C.W.; Hewitt, Alex W.; Jonas, Jost B.; Mitchell, Paul; Lotery, Andrew J.; Foster, Paul J.; Vitart, Veronique; Pfeiffer, Norbert; Craig, Jamie E.; Mackey, David A.; Hammond, Christopher J.; Wiggs, Janey L.; Cheng, Ching-Yu; van Duijn, Cornelia M.; MacGregor, Stuart

    2017-01-01

    Abstract Primary open-angle glaucoma (POAG), the most common optic neuropathy, is a heritable disease. Siblings of POAG cases have a ten-fold increased risk of developing the disease. Intraocular pressure (IOP) and optic nerve head characteristics are used clinically to predict POAG risk. We conducted a genome-wide association meta-analysis of IOP and optic disc parameters and validated our findings in multiple sets of POAG cases and controls. Using imputation to the 1000 genomes (1000G) reference set, we identified 9 new genomic regions associated with vertical cup-disc ratio (VCDR) and 1 new region associated with IOP. Additionally, we found 5 novel loci for optic nerve cup area and 6 for disc area. Previously it was assumed that genetic variation influenced POAG either through IOP or via changes to the optic nerve head; here we present evidence that some genomic regions affect both IOP and the disc parameters. We characterized the effect of the novel loci through pathway analysis and found that pathways involved are not entirely distinct as assumed so far. Further, we identified a novel association between CDKN1A and POAG. Using a zebrafish model we show that six6b (associated with POAG and optic nerve head variation) alters the expression of cdkn1a. In summary, we have identified several novel genes influencing the major clinical risk predictors of POAG and showed that genetic variation in CDKN1A is important in POAG risk. PMID:28073927

  8. Community-based Early Warning and Adaptive Response System (EWARS) for mosquito borne diseases: An open source/open community approach

    NASA Astrophysics Data System (ADS)

    Babu, A. N.; Soman, B.; Niehaus, E.; Shah, J.; Sarda, N. L.; Ramkumar, P. S.; Unnithan, C.

    2014-11-01

    A variety of studies around the world have evaluated the use of remote sensing with and without GIS in communicable diseases. The ongoing Ebola epidemic has highlighted the risks that can arise for the global community from rapidly spreading diseases which may outpace attempts at control and eradication. This paper presents an approach to the development, deployment, validation and wide-spread adoption of a GIS-based temporo-spatial decision support system which is being collaboratively developed in open source/open community mode by an international group that came together under UN auspices. The group believes in an open source/open community approach to make the fruits of knowledge as widely accessible as possible. A core initiative of the groups is the EWARS project. It proposes to strengthen existing public health systems by the development and validation a model for a community based surveillance and response system which will initially address mosquito borne diseases in the developing world. At present mathematical modeling to support EWARS is at an advanced state, and it planned to embark on a pilot project

  9. The Open-Air School Movement in English Education

    ERIC Educational Resources Information Center

    Cruickshank, Marjorie

    1977-01-01

    Begun in the early 1900s, the open-air school movement marked a new chapter in preventive medicine. The schools took undernourished slum students and provided them with food and a hygienic environment. Within half a century the open-air schools had outlived their usefulness because of a social revolution. (Author/IRT)

  10. Recombinational and physical mapping of the locus for primary open-angle glaucoma (GLC1A) on chromosome 1q23-q25

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belmouden, A.; Adam, M.F.; De Dinechin, S.D.

    1997-02-01

    Primary open-angle glaucoma (POAG) is a leading cause of irreversible blindness in industrialized countries. A locus for juvenile-onset POAG, GLC1A, has been mapped to 1q21-q31 in a 9-cM interval. With recombinant haplotypes, we have now reduced the GLC1A interval to a maximum of 3 cM, between the D1S452/NGA1/D1S210 and NGA5 loci. These loci are 2.8 Mb apart on a 4.7-Mb contig that we have completed between the D1S2851 and D1S218 loci and that includes 96 YAC clones and 48 STSs. The new GLC1A interval itself is now covered by 25 YACs, 30 STSs, and 16 restriction enzyme site landmarks. Themore » lack of a NotI site suggests that the region has few CpG islands and a low gene content. This is compatible with its predominant cytogenetic location on the 1q24 G-band. Finally, we have excluded important candidate genes, including genes coding for three ATPases (AMB1, ATP2B4, ATPlA2), an ion channel (VDAC4), antithrombine III (AT3), and prostaglandin synthase (PTGS2). Our results provide a basis to identify the GLC1A gene. 59 refs., 3 figs., 3 tabs.« less

  11. Nanobubbles in confined solution: Generation, contact angle, and stability.

    PubMed

    Wei, Jiachen; Zhang, Xianren; Song, Fan; Shao, Yingfeng

    2018-02-14

    The formation of gas bubbles presents a frequent challenge to microfluidic operations, for which fluids are geometrically confined to a microscale space. Here, to understand the mechanism of nucleating gas bubbles in microfluidic devices, we investigate the formation and stability of nanobubbles in confined solutions. Our molecular dynamics simulations show that while pinning of the contact line is a prerequisite for the stability of surface nanobubbles in open systems that can exchange gas with surrounding environment, in confined solutions, stable nanobubbles can exist even without pinning. In supersaturated condition, stable bubbles can be found in confined solutions with acute or obtuse contact angle, depending on the substrate hydrophobicity. We also demonstrate that when open to the bulk solution, the stable nanobubbles in closed systems would become unstable unless both supersaturation and pinning of the contact line are satisfied. Our results not only shed light on the design of novel heterogeneous surfaces for generating nanobubbles in confined space with controllable shape and stability but also address the crucial effect of gas exchange with the surroundings in determining the stability of nanobubbles.

  12. Nanobubbles in confined solution: Generation, contact angle, and stability

    NASA Astrophysics Data System (ADS)

    Wei, Jiachen; Zhang, Xianren; Song, Fan; Shao, Yingfeng

    2018-02-01

    The formation of gas bubbles presents a frequent challenge to microfluidic operations, for which fluids are geometrically confined to a microscale space. Here, to understand the mechanism of nucleating gas bubbles in microfluidic devices, we investigate the formation and stability of nanobubbles in confined solutions. Our molecular dynamics simulations show that while pinning of the contact line is a prerequisite for the stability of surface nanobubbles in open systems that can exchange gas with surrounding environment, in confined solutions, stable nanobubbles can exist even without pinning. In supersaturated condition, stable bubbles can be found in confined solutions with acute or obtuse contact angle, depending on the substrate hydrophobicity. We also demonstrate that when open to the bulk solution, the stable nanobubbles in closed systems would become unstable unless both supersaturation and pinning of the contact line are satisfied. Our results not only shed light on the design of novel heterogeneous surfaces for generating nanobubbles in confined space with controllable shape and stability but also address the crucial effect of gas exchange with the surroundings in determining the stability of nanobubbles.

  13. Bilateral mandibular angle fractures: clinical considerations.

    PubMed

    Boffano, Paolo; Roccia, Fabio

    2010-03-01

    The mandibular angle is a frequent site of fracture. It is a weak zone that is more exposed to fractures than other areas of the mandibular bone. The presence of incompletely erupted third molars is associated with a further increased risk of angle fractures. Our objective was to evaluate and discuss the surgical outcomes of a group of patients with bilateral mandibular angle fractures.In our study, patients with bilateral mandibular angle fractures surgically treated from January 1, 2001, to June 30, 2009, at the Division of Maxillofacial Surgery of the University of Turin were retrospectively analyzed. A combined transbuccal and intraoral approach or an intraoral approach only was adopted.Eight patients (7 men and 1 woman) underwent surgery for bilateral mandibular angle fractures. Good to satisfactory reduction of the fractures was obtained with both surgical techniques. Good to fair restored occlusion was observed postoperatively in all patients.Successful treatment of bilateral mandibular angle fractures may be achieved via different techniques. Superficially impacted third molars seem to be associated with an increased risk of angle fractures. Bilateral angle fractures are an ideal model to study the biomechanical pathogenesis of angle fractures.

  14. Early weight bearing versus delayed weight bearing in medial opening wedge high tibial osteotomy: a randomized controlled trial.

    PubMed

    Lansdaal, Joris Radboud; Mouton, Tanguy; Wascher, Daniel Charles; Demey, Guillaume; Lustig, Sebastien; Neyret, Philippe; Servien, Elvire

    2017-12-01

    The need for a period of non-weight bearing after medial opening wedge high tibial osteotomy remains controversial. It is hypothesized that immediate weight bearing after medial opening wedge high tibial osteotomy would have no difference in functional scores at one year compared to delayed weight bearing. Fifty patients, median age 54 years (range 40-65), with medial compartment osteoarthritis, underwent a medial opening wedge high tibial osteotomy utilizing a locking plate without bone grafting. Patients were randomized into an Immediate or a Delayed (2 months) weight bearing group. All patients were assessed at one-year follow-up and the two groups compared. The primary outcome measure was the IKS score. Secondary outcome measures included the IKDC score, the VAS pain score and rate of complications. The functional scores significantly improved in both groups. The IKS score increased from 142 ± 31 to 171 ± 26 in the Immediate group (p < 0.001) and from 148 ± 22 to 178 ± 23 in the Delayed group (p < 0.001). The IKDC score increased from 49 ± 17 pre-operatively to 68 ± 14 one-year post-operatively in the Immediate group (p < 0.0001) and from 44 ± 16 to 69 ± 19 in the Delayed group (p < 0.001). The average VAS for pain 2 months after surgery was 3 ± 3 in the Immediate group and 3 ± 2 in the Delayed (n.s.). There was no significant difference between the two groups in any of the outcome measures. The mean mechanical femorotibial angle changed from 6° of varus (0°-15° of varus, SD = 3°) to 4° of valgus (5°-11° of valgus, SD = 3°) in the Immediate group and from 5° of varus (0°-10° of varus, SD = 3°) to 3° of valgus (2° of varus to 8° of valgus, SD = 3°) in the Delayed group. No difference was seen between groups, and no loss of correction was observed in any patient. Two cases of non-union occurred, one in each group. One infection and one deep vein thrombosis occurred in the Immediate group. Immediate

  15. Open ocean Internal Waves, Namibia Coast, Africa.

    NASA Image and Video Library

    1990-12-10

    These open ocean Internal Waves were seen off the Namibia Coast, Africa (23.0S, 14.0E). The periodic and regularly spaced sets of internal waves most likely coincide with tidal periods about 12 hours apart. The wave length (distance from crest to crest) varies between 1.5 and 5.0 miles and the crest lengths stretch across and beyond the distance of the photo. The waves are intersecting the Namibia coastline at about a 30 degree angle.

  16. Open ocean Internal Waves, Namibia Coast, Africa.

    NASA Technical Reports Server (NTRS)

    1990-01-01

    These open ocean Internal Waves were seen off the Namibia Coast, Africa (23.0S, 14.0E). The periodic and regularly spaced sets of internal waves most likely coincide with tidal periods about 12 hours apart. The wave length (distance from crest to crest) varies between 1.5 and 5.0 miles and the crest lengths stretch across and beyond the distance of the photo. The waves are intersecting the Namibia coastline at about a 30 degree angle.

  17. Oscillations of a sessile droplet in open air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Korenchenko, A. E., E-mail: korenchenko@physics.susu.ac.ru; Beskachko, V. P.

    2013-11-15

    The open system consisting of a sessile drop, a neutral gas, and a substrate is analyzed by numerical methods. The mode with constant contact angle is considered. The model takes into account evaporation from drop surface, free and forced convection in gas, buoyancy, and Marangoni effect in the liquid phase. It was established that every considered mechanical and thermodynamical disturbance of the system leads to the drop surface oscillations, and thus a drop in an open air oscillates almost inevitably. The displacement of the liquid-gas interface due to oscillations is analyzed in terms of its impact on the accuracy ofmore » measurement of the surface tension by sessile drop method.« less

  18. Reading angles in maps.

    PubMed

    Izard, Véronique; O'Donnell, Evan; Spelke, Elizabeth S

    2014-01-01

    Preschool children can navigate by simple geometric maps of the environment, but the nature of the geometric relations they use in map reading remains unclear. Here, children were tested specifically on their sensitivity to angle. Forty-eight children (age 47:15-53:30 months) were presented with fragments of geometric maps, in which angle sections appeared without any relevant length or distance information. Children were able to read these map fragments and compare two-dimensional to three-dimensional angles. However, this ability appeared both variable and fragile among the youngest children of the sample. These findings suggest that 4-year-old children begin to form an abstract concept of angle that applies both to two-dimensional and three-dimensional displays and that serves to interpret novel spatial symbols. © 2013 The Authors. Child Development © 2013 Society for Research in Child Development, Inc.

  19. Anterior Segment Imaging for Angle Closure.

    PubMed

    Chansangpetch, Sunee; Rojanapongpun, Prin; Lin, Shan C

    2018-04-01

    To summarize the role of anterior segment imaging (AS-imaging) in angle closure diagnosis and management, and the possible advantages over the current standard of gonioscopy. Literature review and perspective. Review of the pertinent publications with interpretation and perspective in relation to the use of AS-imaging in angle closure assessment focusing on anterior segment optical coherence tomography and ultrasound biomicroscopy. Several limitations have been encountered with the reference standard of gonioscopy for angle assessment. AS-imaging has been shown to have performance in angle closure detection compared to gonioscopy. Also, imaging has greater reproducibility and serves as better documentation for long-term follow-up than conventional gonioscopy. The qualitative and quantitative information obtained from AS-imaging enables better understanding of the underlying mechanisms of angle closure and provides useful parameters for risk assessment and possible prediction of the response to laser and surgical intervention. The latest technologies-including 3-dimensional imaging-have allowed for the assessment of the angle that simulates the gonioscopic view. These advantages suggest that AS-imaging has a potential to be a reference standard for the diagnosis and monitoring of angle closure disease in the future. Although gonioscopy remains the primary method of angle assessment, AS-imaging has an increasing role in angle closure screening and management. The test should be integrated into clinical practice as an adjunctive tool for angle assessment. It is arguable that AS-imaging should be considered first-line screening for patients at risk for angle closure. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Clustering of water molecules in ultramicroporous carbon: In-situ small-angle neutron scattering

    DOE PAGES

    Bahadur, Jitendra; Contescu, Cristian I.; Rai, Durgesh K.; ...

    2016-10-19

    The adsorption of water is central to most of the applications of microporous carbon as adsorbent material. We report early kinetics of water adsorption in the microporous carbon using in-situ small-angle neutron scattering. It is observed that adsorption of water occurs via cluster formation of molecules. Interestingly, the cluster size remains constant throughout the adsorption process whereas number density of clusters increases with time. The role of surface chemistry of microporous carbon on the early kinetics of adsorption process was also investigated. Lastly, the present study provides direct experimental evidence for cluster assisted adsorption of water molecules in microporous carbonmore » (Do-Do model).« less

  1. A platform for dynamic simulation and control of movement based on OpenSim and MATLAB.

    PubMed

    Mansouri, Misagh; Reinbolt, Jeffrey A

    2012-05-11

    Numerical simulations play an important role in solving complex engineering problems and have the potential to revolutionize medical decision making and treatment strategies. In this paper, we combine the rapid model-based design, control systems and powerful numerical method strengths of MATLAB/Simulink with the simulation and human movement dynamics strengths of OpenSim by developing a new interface between the two software tools. OpenSim is integrated with Simulink using the MATLAB S-function mechanism, and the interface is demonstrated using both open-loop and closed-loop control systems. While the open-loop system uses MATLAB/Simulink to separately reproduce the OpenSim Forward Dynamics Tool, the closed-loop system adds the unique feature of feedback control to OpenSim, which is necessary for most human movement simulations. An arm model example was successfully used in both open-loop and closed-loop cases. For the open-loop case, the simulation reproduced results from the OpenSim Forward Dynamics Tool with root mean square (RMS) differences of 0.03° for the shoulder elevation angle and 0.06° for the elbow flexion angle. MATLAB's variable step-size integrator reduced the time required to generate the forward dynamic simulation from 7.1s (OpenSim) to 2.9s (MATLAB). For the closed-loop case, a proportional-integral-derivative controller was used to successfully balance a pole on model's hand despite random force disturbances on the pole. The new interface presented here not only integrates the OpenSim and MATLAB/Simulink software tools, but also will allow neuroscientists, physiologists, biomechanists, and physical therapists to adapt and generate new solutions as treatments for musculoskeletal conditions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Angle-Ply Weaving

    NASA Technical Reports Server (NTRS)

    Farley, Gary L.

    1990-01-01

    Bias-direction or angle-ply weaving is proposed new process for weaving fibers along bias in conventional planar fabric or in complicated three-dimensional multilayer fabric preform of fiber-reinforced composite structure. Based upon movement of racks of needles and corresponding angle yarns across fabric as fabric being formed. Fibers woven along bias increases shear stiffness and shear strength of preform, increasing value of preform as structural member.

  3. Breathing pattern and head posture: changes in craniocervical angles.

    PubMed

    Sabatucci, A; Raffaeli, F; Mastrovincenzo, M; Luchetta, A; Giannone, A; Ciavarella, D

    2015-04-01

    The aim of this study was to observe the influence of oral breathing on head posture and to establish possible postural changes observing the variation of craniocervical angles NSL/OPT and NSL/CVT between oral breathing subjects and physiological breathing subjects. A cross-sectional study was conducted. The sample included 115 subject, 56 boys and 59 girls, 5-22-year-old. Among these, 80 were classified as oral breathers and 35 as physiological breathers. The diagnosis of oral breathing was carried out thanks to characteristic signs and symptoms evaluated on clinical examination, the analysis of characteristic X-ray images, ENT examination with active anterior rhinomanometric (AAR) test. The structural and postural analysis was carried out, calculating the craniofacial angles NSL/OPT and NSL/CVT. Both NSL/OPT and NSL/CVT appear to be significantly greater to those observed in physiological breathing patients. This means that patients who tend to breathe through the mouth rather than exclusively through the nose show a reduction of cervical lordosis and a proinclination of the head. Our study confirms that the oral breathing modifies head position. The significant increase of the craniocervical angles NSL/OPT and NSL/CVT in patients with this altered breathing pattern suggests an elevation of the head and a greater extension of the head compared with the cervical spine. So, to correct the breathing pattern early, either during childhood or during adolescence, can lead to a progressive normalization of craniofacial morphology and head posture.

  4. Long-term safety and tolerability of rotigotine transdermal system in patients with early-stage idiopathic Parkinson's disease: a prospective, open-label extension study.

    PubMed

    Elmer, Lawrence W; Surmann, Erwin; Boroojerdi, Babak; Jankovic, Joseph

    2012-06-01

    This prospective, open-label extension (SP702; NCT00594165) of a 6-month double-blind, randomized study investigated the long-term safety and tolerability of rotigotine transdermal system in early Parkinson's disease (PD). Patients with early-stage idiopathic PD received transdermal rotigotine for up to 6 years at optimal dose (up to 16 mg/24h). Adjunctive levodopa was allowed. Primary outcomes included adverse events (AEs) and extent of rotigotine exposure. Other outcomes included time to levodopa, incidence of dyskinesias, and efficacy using the Unified Parkinson's Disease Rating Scale (UPDRS) II+III total score. Of 217 patients entering the open-label study, 47% were still in the study upon closure; 24% withdrew because of AEs and 6% because of lack of efficacy. The median exposure to rotigotine was 1910 days (≈ 5 years, 3 months; range 1-2188 days). Most common AEs were somnolence (23% per patient-year), falls (17%), peripheral edema (14%), nausea (12%), and application site reactions (ASRs; 12%). 3% withdrew because of ASRs. 26% patients did not initiate levodopa; of those who did, fewer than half started levodopa in the first year. Dyskinesias were reported by 25% patients; the majority (83%) reported their first episode after initiating levodopa. Mean UPDRS II+III total scores remained below double-blind baseline for up to 2 years of open-label treatment. This is the longest interventional study of rotigotine conducted to date. Transdermal rotigotine was generally well tolerated for up to 6 years; AEs reported were similar to those observed in shorter studies and led to discontinuation in only 24% patients. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Wafer scale oblique angle plasma etching

    DOEpatents

    Burckel, David Bruce; Jarecki, Jr., Robert L.; Finnegan, Patrick Sean

    2017-05-23

    Wafer scale oblique angle etching of a semiconductor substrate is performed in a conventional plasma etch chamber by using a fixture that supports a multiple number of separate Faraday cages. Each cage is formed to include an angled grid surface and is positioned such that it will be positioned over a separate one of the die locations on the wafer surface when the fixture is placed over the wafer. The presence of the Faraday cages influences the local electric field surrounding each wafer die, re-shaping the local field to be disposed in alignment with the angled grid surface. The re-shaped plasma causes the reactive ions to follow a linear trajectory through the plasma sheath and angled grid surface, ultimately impinging the wafer surface at an angle. The selected geometry of the Faraday cage angled grid surface thus determines the angle at with the reactive ions will impinge the wafer.

  6. Spinning angle optical calibration apparatus

    DOEpatents

    Beer, Stephen K.; Pratt, II, Harold R.

    1991-01-01

    An optical calibration apparatus is provided for calibrating and reproducing spinning angles in cross-polarization, nuclear magnetic resonance spectroscopy. An illuminated magnifying apparatus enables optical setting an accurate reproducing of spinning "magic angles" in cross-polarization, nuclear magnetic resonance spectroscopy experiments. A reference mark scribed on an edge of a spinning angle test sample holder is illuminated by a light source and viewed through a magnifying scope. When the "magic angle" of a sample material used as a standard is attained by varying the angular position of the sample holder, the coordinate position of the reference mark relative to a graduation or graduations on a reticle in the magnifying scope is noted. Thereafter, the spinning "magic angle" of a test material having similar nuclear properties to the standard is attained by returning the sample holder back to the originally noted coordinate position.

  7. Wicket gate trailing-edge blowing: A method for improving off-design hydroturbine performance by adjusting the runner inlet swirl angle

    NASA Astrophysics Data System (ADS)

    Lewis, B. J.; Cimbala, J. M.; Wouden, A. M.

    2014-03-01

    At their best efficiency point (BEP), hydroturbines operate at very high efficiency. However, with the ever-increasing penetration of alternative electricity generation, it has become common to operate hydroturbines at off-design conditions in order to maintain stability in the electric power grid. This paper demonstrates a method for improving hydroturbine performance during off-design operation by injecting water through slots at the trailing edges of the wicket gates. The injected water causes a change in bulk flow direction at the inlet of the runner. This change in flow angle from the wicket gate trailing-edge jets provides the capability of independently varying the flow rate and swirl angle through the runner, which in current designs are both determined by the wicket gate opening angle. When properly tuned, altering the flow angle results in a significant improvement in turbine efficiency during off-design operation.

  8. Estrogen pathway polymorphisms in relation to primary open angle glaucoma: An analysis accounting for gender from the United States

    PubMed Central

    Loomis, Stephanie J.; Weinreb, Robert N.; Kang, Jae H.; Yaspan, Brian L.; Bailey, Jessica Cooke; Gaasterland, Douglas; Gaasterland, Terry; Lee, Richard K.; Scott, William K.; Lichter, Paul R.; Budenz, Donald L.; Liu, Yutao; Realini, Tony; Friedman, David S.; McCarty, Catherine A.; Moroi, Sayoko E.; Olson, Lana; Schuman, Joel S.; Singh, Kuldev; Vollrath, Douglas; Wollstein, Gadi; Zack, Donald J.; Brilliant, Murray; Sit, Arthur J.; Christen, William G.; Fingert, John; Kraft, Peter; Zhang, Kang; Allingham, R. Rand; Pericak-Vance, Margaret A.; Richards, Julia E.; Hauser, Michael A.; Haines, Jonathan L.; Wiggs, Janey L.

    2013-01-01

    Purpose Circulating estrogen levels are relevant in glaucoma phenotypic traits. We assessed the association between an estrogen metabolism single nucleotide polymorphism (SNP) panel in relation to primary open angle glaucoma (POAG), accounting for gender. Methods We included 3,108 POAG cases and 3,430 controls of both genders from the Glaucoma Genes and Environment (GLAUGEN) study and the National Eye Institute Glaucoma Human Genetics Collaboration (NEIGHBOR) consortium genotyped on the Illumina 660W-Quad platform. We assessed the relation between the SNP panels representative of estrogen metabolism and POAG using pathway- and gene-based approaches with the Pathway Analysis by Randomization Incorporating Structure (PARIS) software. PARIS executes a permutation algorithm to assess statistical significance relative to the pathways and genes of comparable genetic architecture. These analyses were performed using the meta-analyzed results from the GLAUGEN and NEIGHBOR data sets. We evaluated POAG overall as well as two subtypes of POAG defined as intraocular pressure (IOP) ≥22 mmHg (high-pressure glaucoma [HPG]) or IOP <22 mmHg (normal pressure glaucoma [NPG]) at diagnosis. We conducted these analyses for each gender separately and then jointly in men and women. Results Among women, the estrogen SNP pathway was associated with POAG overall (permuted p=0.006) and HPG (permuted p<0.001) but not NPG (permuted p=0.09). Interestingly, there was no relation between the estrogen SNP pathway and POAG when men were considered alone (permuted p>0.99). Among women, gene-based analyses revealed that the catechol-O-methyltransferase gene showed strong associations with HTG (permuted gene p≤0.001) and NPG (permuted gene p=0.01). Conclusions The estrogen SNP pathway was associated with POAG among women. PMID:23869166

  9. Differential Protein Expression Profiles in Glaucomatous Trabecular Meshwork: An Evaluation Study on a Small Primary Open Angle Glaucoma Population.

    PubMed

    Micera, Alessandra; Quaranta, Luciano; Esposito, Graziana; Floriani, Irene; Pocobelli, Augusto; Saccà, Sergio Claudio; Riva, Ivano; Manni, Gianluca; Oddone, Francesco

    2016-02-01

    Primary open angle glaucoma (POAG) is a progressive optic neuropathy characterized by impaired aqueous outflow and extensive remodeling in the trabecular meshwork (TM). The aim of this study was to characterize and compare the expression patterns of selected proteins belonging to the tissue remodeling, inflammation and growth factor pathways in ex vivo glaucomatous and post-mortem TMs using protein-array analysis. TM specimens were collected from 63 white subjects, including 40 patients with glaucoma and 23 controls. Forty POAG TMs were collected at the time of surgery and 23 post-mortem specimens were from non-glaucomatous donor sclerocorneal tissues. Protein profiles were evaluated using a chip-based array consisting of 60 literature-selected antibodies. A different expression of some factors was observed in POAG TMs with respect to post-mortem specimens, either in abundance (interleukin [IL]10, IL6, IL5, IL7, IL12, IL3, macrophage inflammatory protein [MIP]1δ/α, vascular endothelial growth factor [VEGF], transforming growth factor beta 1 [TGFβ1], soluble tumor necrosis factor receptor I [sTNFRI]) or in scarcity (IL16, IL18, intercellular adhesion molecule 3 [ICAM3], matrix metalloproteinase-7 [MMP7], tissue inhibitor of metalloproteinase 1 [TIMP1]). MMP2, MMP7, TGFβ1, and VEGF expressions were confirmed by Western blot, zymography, and polymerase chain reaction. No difference in protein profile expression was detected between glaucomatous subtypes. The analysis of this small TM population highlighted some proteins linked to POAG, some previously reported and others of new detection (IL7, MIPs, sTNFαRI). A larger POAG population is required to select promising disease-associated biomarker candidates. This study was partially supported by the Fondazione Roma, the Italian Ministry of Health and the "National 5xMille 2010 tax donation to IRCCS-G.B. Bietti Foundation".

  10. Effect of dorzolamide and timolol on ocular blood flow in patients with primary open angle glaucoma and ocular hypertension

    PubMed Central

    Fuchsjäger-Mayrl, G; Wally, B; Rainer, G; Buehl, W; Aggermann, T; Kolodjaschna, J; Weigert, G; Polska, E; Eichler, H-G; Vass, C; Schmetterer, L

    2005-01-01

    Background: There is evidence that perfusion abnormalities of the optic nerve head are involved in the pathogenesis of glaucoma. There is therefore considerable interest in the effects of topical antiglaucoma drugs on ocular blood flow. A study was undertaken to compare the ocular haemodynamic effects of dorzolamide and timolol in patients with primary open angle glaucoma (POAG) or ocular hypertension (OHT). Methods: One hundred and forty patients with POAG or OHT were included in a controlled, randomised, double blind study in two parallel groups; 70 were randomised to receive timolol and 70 to receive dorzolamide for a period of 6 months. Subjects whose intraocular pressure (IOP) did not respond to either of the two drugs were switched to the alternative treatment after 2 weeks. Scanning laser Doppler flowmetry was used to measure blood flow in the temporal neuroretinal rim and the cup of the optic nerve head. Pulsatile choroidal blood flow was assessed using laser interferometric measurement of fundus pulsation amplitude. Results: Five patients did not respond to timolol and were changed to the dorzolamide group, and 18 patients changed from dorzolamide treatment to timolol. The effects of both drugs on IOP and ocular perfusion pressure were comparable. Dorzolamide, but not timolol, increased blood flow in the temporal neuroretinal rim (8.5 (1.6)%, p<0.001 versus timolol) and the cup of the optic nerve head (13.5 (2.5)%, p<0.001 versus timolol), and fundus pulsation amplitude (8.9 (1.3)%, p<0.001 versus timolol). Conclusions: This study indicates augmented blood flow in the optic nerve head and choroid after 6 months of treatment with dorzolamide, but not with timolol. It remains to be established whether this effect can help to reduce visual field loss in patients with glaucoma. PMID:16170119

  11. Genome-wide analysis of central corneal thickness in primary open-angle glaucoma cases in the NEIGHBOR and GLAUGEN consortia.

    PubMed

    Ulmer, Megan; Li, Jun; Yaspan, Brian L; Ozel, Ayse Bilge; Richards, Julia E; Moroi, Sayoko E; Hawthorne, Felicia; Budenz, Donald L; Friedman, David S; Gaasterland, Douglas; Haines, Jonathan; Kang, Jae H; Lee, Richard; Lichter, Paul; Liu, Yutao; Pasquale, Louis R; Pericak-Vance, Margaret; Realini, Anthony; Schuman, Joel S; Singh, Kuldev; Vollrath, Douglas; Weinreb, Robert; Wollstein, Gadi; Zack, Donald J; Zhang, Kang; Young, Terri; Allingham, R Rand; Wiggs, Janey L; Ashley-Koch, Allison; Hauser, Michael A

    2012-07-03

    To investigate the effects of central corneal thickness (CCT)-associated variants on primary open-angle glaucoma (POAG) risk using single nucleotide polymorphisms (SNP) data from the Glaucoma Genes and Environment (GLAUGEN) and National Eye Institute (NEI) Glaucoma Human Genetics Collaboration (NEIGHBOR) consortia. A replication analysis of previously reported CCT SNPs was performed in a CCT dataset (n = 1117) and these SNPs were then tested for association with POAG using a larger POAG dataset (n = 6470). Then a CCT genome-wide association study (GWAS) was performed. Top SNPs from this analysis were selected and tested for association with POAG. cDNA libraries from fetal and adult brain and ocular tissue samples were generated and used for candidate gene expression analysis. Association with one of 20 previously published CCT SNPs was replicated: rs12447690, near the ZNF469 gene (P = 0.001; β = -5.08 μm/allele). None of these SNPs were significantly associated with POAG. In the CCT GWAS, no SNPs reached genome-wide significance. After testing 50 candidate SNPs for association with POAG, one SNP was identified, rs7481514 within the neurotrimin (NTM) gene, that was significantly associated with POAG in a low-tension subset (P = 0.00099; Odds Ratio [OR] = 1.28). Additionally, SNPs in the CNTNAP4 gene showed suggestive association with POAG (top SNP = rs1428758; P = 0.018; OR = 0.84). NTM and CNTNAP4 were shown to be expressed in ocular tissues. The results suggest previously reported CCT loci are not significantly associated with POAG susceptibility. By performing a quantitative analysis of CCT and a subsequent analysis of POAG, SNPs in two cell adhesion molecules, NTM and CNTNAP4, were identified and may increase POAG susceptibility in a subset of cases.

  12. Effect of EMIC Wave Normal Angle Distribution on Relativistic Electron Scattering

    NASA Technical Reports Server (NTRS)

    Gamayunov, K. V.; Khazanov, G. V.

    2006-01-01

    The flux level of outer-zone relativistic electrons (above 1 MeV) is extremely variable during geomagnetic storms, and controlled by a competition between acceleration and loss. Precipitation of these electrons due to resonant pitch-angle scattering by electromagnetic ion cyclotron (EMIC) waves is considered one of the major loss mechanisms. This mechanism was suggested in early theoretical studies more than three decades ago. However, direct experimental evidence of the wave role in relativistic electrons precipitation is difficult to obtain because of lack of concurrent measurements of precipitating electrons at low altitudes and the waves in a magnetically conjugate equatorial region. Recently, the data from balloon-borne X-ray instruments provided indirect but strong evidence on an efficiency of the EMIC wave induced loss for the outer-zone relativistic electrons. These observations stimulated theoretical studies that, particularly, demonstrated that EMIC wave induced pitch-angle diffusion of MeV electrons can operate in the strong diffusion limit and this mechanism can compete with relativistic electron depletion caused by the Dst effect during the initial and main phases of storm. Although an effectiveness of relativistic electron scattering by EMIC waves depends strongly on the wave spectral properties, the most favorable assumptions regarding wave characteristics has been made in all previous theoretical studies. Particularly, only quasi field-aligned EMIC waves have been considered as a driver for relativistic electron loss. At the same time, there is growing experimental and theoretical evidence that these waves can be highly oblique; EMIC wave energy can occupy not only the region of generation, i.e. the region of small wave normal angles, but also the entire wave normal angle region, and even only the region near 90 degrees. The latter can dramatically change he effectiveness of relativistic electron scattering by EMIC waves. In the present study, we

  13. [PERSONALIZED DISTAL FEMORAL VALGUS RESECTION ANGLE IN PRIMARY TOTAL KNEE ARTHROPLASTY].

    PubMed

    Wang, Xilong; Shang, Xifu; Ll, Guoyuan; He, Rui; Zheng, Jie

    2015-01-01

    To investigate the feasibility and effectiveness of a personalized distal femoral valgus resection angle for improving postoperative coronal alignment of lower limb in total knee arthroplasty (TKA). A retrospective analysis was made on the clinical data of 50 patients who received primary TKA between January 2013 and February 2013. There were 11 male and 39 female patients with degenerative knee osteoarthritis. The patients were divided into 2 groups. In test group (n=25), the resection angle was adjusted to the femoral mechanical anatomical angle (FMA); in control group (n=25), a fixed distal valgus resection angle of 5° was used. There was no significant difference in gender, age, body mass index, disease duration, sides, grade, preoperative FMA, mechanical femorotibial angle (MFT), and preoperative Knee Society Score (KSS) between 2 groups (P > 0.05). Whole long X-ray film was taken to measure FMA and MFT at 3 days after operation, postoperative KSS was used to evaluate the knee function after 6 and 15 months. MFT was (-0.20 ± 1.87)° in test group and was (1.71 ± 3.67)° in control group, showing significant difference between 2 groups (t = 2.32, P = 0.02). The ideal MFT angle (0 ± 3)° was achieved in 22 patients (88%) of test group and in 16 patients (64%) of control group, showing significant difference between 2 groups (χ2 = 2.32, P = 0.02). Primary healing of incision was obtained in all patients of 2 groups. No deep venous thrombosis occurred. The patients of 2 groups were followed up 15 months after operation. There was significant difference in KSS between test and control groups at 6 months (88.23 ± 2.57 vs. 82.92 ± 2.59) (t = 7.26, P = 0.00) and at 15 months (90.76 ± 2.77 vs. 88.65 ± 1.77) (t = 3.20, P = 0.02). No sign of prosthesis loosening was observed by X-ray examination. Compared with using of a fixed distal femoral resection angle, an individual FMA can significantly improve the postoperative MFT and promote early recovery of the knee

  14. Relationship between intraocular pressure and angle configuration: an anterior segment OCT study.

    PubMed

    Chong, Rachel S; Sakata, Lisandro M; Narayanaswamy, Arun K; Ho, Sue-Wei; He, Mingguang; Baskaran, Mani; Wong, Tien Yin; Perera, Shamira A; Aung, Tin

    2013-03-05

    To assess the relationship between intraocular pressure (IOP) and anterior chamber angle (ACA) configuration as assessed by gonioscopy and anterior segment optical coherence tomography (AS-OCT). A total of 2045 subjects aged 50 years and older, were recruited from a community clinic and underwent AS-OCT, Goldmann applanation tonometry, and gonioscopy. A quadrant was classified as closed on gonioscopy if the posterior trabecular meshwork could not be seen. A closed quadrant on AS-OCT was defined by the presence of any contact between the iris and angle wall anterior to the scleral spur. Customized software (Zhongshan Angle Assessment Program, Guangzhou, China) was used to measure AS-OCT parameters on AS-OCT scans, including anterior chamber depth, area, and volume; iris thickness (IT) and curvature; lens vault; angle opening distance; and trabecular-iris space area. IOP values were adjusted for age, sex, diabetes and hypertension status, body mass index, central corneal thickness, and presence of peripheral anterior synechiae. Mean age of study subjects was 63.2 ± 8.0 years, 52.6% were female, and 89.4% were Chinese. Mean IOP was 14.8 ± 2.4 mm Hg (range 826). IOP (mean ± SE) increased with number of quadrants with gonioscopic angle closure (none: 14.6 ± 0.2; one: 14.7 ± 0.3; two: 15.0 ± 0.3; three: 15.0 ± 0.3; four: 15.6 ± 0.3 mm Hg; P < 0.001), and on AS-OCT (none: 14.7 ± 0.2; one: 15.0 ± 0.2; two: 14.8 ± 0.2; three: 15.1 ± 0.3; four: 16.0 ± 0.3 mm Hg; P < 0.001). IOP also increased in association with most of the ACA quantitative parameters measured on AS-OCT images, except for IT and lens vault. There was an association between the extent of angle closure, as assessed on AS-OCT and gonioscopy, with increasing IOP.

  15. Three-dimensional super-resolved live cell imaging through polarized multi-angle TIRF.

    PubMed

    Zheng, Cheng; Zhao, Guangyuan; Liu, Wenjie; Chen, Youhua; Zhang, Zhimin; Jin, Luhong; Xu, Yingke; Kuang, Cuifang; Liu, Xu

    2018-04-01

    Measuring three-dimensional nanoscale cellular structures is challenging, especially when the structure is dynamic. Owing to the informative total internal reflection fluorescence (TIRF) imaging under varied illumination angles, multi-angle (MA) TIRF has been examined to offer a nanoscale axial and a subsecond temporal resolution. However, conventional MA-TIRF still performs badly in lateral resolution and fails to characterize the depth image in densely distributed regions. Here, we emphasize the lateral super-resolution in the MA-TIRF, exampled by simply introducing polarization modulation into the illumination procedure. Equipped with a sparsity and accelerated proximal algorithm, we examine a more precise 3D sample structure compared with previous methods, enabling live cell imaging with a temporal resolution of 2 s and recovering high-resolution mitochondria fission and fusion processes. We also shared the recovery program, which is the first open-source recovery code for MA-TIRF, to the best of our knowledge.

  16. Does the addition of deep breathing exercises to physiotherapy-directed early mobilisation alter patient outcomes following high-risk open upper abdominal surgery? Cluster randomised controlled trial.

    PubMed

    Silva, Y R; Li, S K; Rickard, M J F X

    2013-09-01

    To investigate whether the inclusion of deep breathing exercises in physiotherapy-directed early mobilisation confers any additional benefit in reducing postoperative pulmonary complications (PPCs) when patients are treated once daily after elective open upper abdominal surgery. This study also compared postoperative outcomes following early and delayed mobilisation. Cluster randomised controlled trial. Single-centre study in a teaching hospital. Eighty-six high-risk patients undergoing elective open upper abdominal surgery. Three groups: early mobilisation (Group A), early mobilisation plus breathing exercises (Group B), and delayed mobilisation (mobilised from third postoperative day) plus breathing exercises (Group C). PPCs and postoperative outcomes [number of days until discharge from physiotherapy, physiotherapy input and length of stay (LOS)]. There was no significant difference in PPCs between Groups A and B. The LOS for Group A {mean 10.7 [standard deviation (SD) 5.0] days} was significantly shorter than the LOS for Groups B [mean 16.7 (SD 9.7) days] and C [mean 15.2 (SD 9.8) days; P=0.036]. The greatest difference was between Groups A and B (mean difference -5.93, 95% confidence interval -10.22 to -1.65; P=0.008). Group C had fewer smokers (26%) and patients with chronic obstructive pulmonary disease (0%) compared with Group B (53% and 14%, respectively). This may have led to fewer PPCs in Group C, but the difference was not significant. Despite Group C having fewer PPCs and less physiotherapy input, the number of days until discharge from physiotherapy and LOS were similar to Group B. The addition of deep breathing exercises to physiotherapy-directed early mobilisation did not further reduce PPCs compared with mobility alone. PPCs can be reduced with once-daily physiotherapy if the patients are mobilised to a moderate level of exertion. Delayed mobilisation tended to increase physiotherapy input and the number of days until discharge from physiotherapy

  17. A dynamic study of the anterior cruciate ligament of the knee using an open MRI.

    PubMed

    Guenoun, Daphne; Vaccaro, Julien; Le Corroller, Thomas; Barral, Pierre-Antoine; Lagier, Aude; Pauly, Vanessa; Coquart, Benjamin; Coste, Joel; Champsaur, Pierre

    2017-03-01

    Recent anatomical and radiological studies of the anterior cruciate ligament (ACL) suggest the ACL length and orientation change during knee flexion, and an open MRI sequencing during knee flexion enables a dynamic ACL analysis. This study's goal is to describe a normal ACL using a 1T open MRI and, in particular, variations in length and insertion angles at different degrees of flexion. Twenty-one volunteers with clinically healthy knees received a dynamic MRI with their knees in hyperextension, neutral position, and flexed at 45° and 90° angles. For each position, two radiologists measured the ACL lengths and angles of the proximal insertion between the ACL's anterior edge and the roof of the inter-condylar notch. Additionally, we measured the ACL's and the tibial plateau's distal angle insertion between their anterior edges and then compared these with the nonparametric Wilcoxon test. The ACL had a significant extension between the 90° flexion and all other positions (hyperextension: 31.75 ± 2.5 mm, neutral position: 32.5 ± 2.6 mm, 45°: 35.6 ± 1.6 mm, 90°: 35.6 ± 1.6 mm). There was also a significant increase of the angle insertion between the proximal 90° flexion and all other positions, as well as between hyperextension and bending to 45° (hyperextension: 2.45° ± 3.7°, neutral: 13.4° ± 9.7°, 45°: 33 25 ± 9.3, 90: 51.85° ± 9.3°). Additionally, there is a significant increase in the distal angle insertion for all positions (hyperextension: 133.2° ± 5.4°, neutral position: 134.95° ± 4.4°, 45°: 138.35° ± 5.9°, 90°: 149.15° ± 8.6°). Our study is the first to exhibit that a dynamic MRI has a significant ACL extension in vivo during bending. This concept opens the way for further studies to improve the diagnosis of traumatic ACL injuries using a dynamic MRI.

  18. Numerical exploration of non-axisymmetric divertor closure in the small angle slot (SAS) divertor at DIII-D

    NASA Astrophysics Data System (ADS)

    Frerichs, Heinke; Schmitz, Oliver; Covele, Brent; Guo, Houyang; Hill, David; Feng, Yuhe

    2017-10-01

    In the Small Angle Slot (SAS) divertor in DIII-D, the combination of misaligned slot structure and non-axisymmetric perturbations to the magnetic field causes the strike point to vary radially along the divertor slot and even leave it at some toroidal locations. This effect essentially introduces an opening in the divertor slot from where recycling neutrals can easily escape, and thereby degrade performance of the slot divertor. This effect has been approximated by a finite gap in the divertor baffle. Simulations with EMC3-EIRENE show that a toroidally localized loss of divertor closure can result in non-axisymmetric divertor densities and temperatures. This introduces a density window of 10-15% on top of the nominal threshold separatrix density during which a non-axisymmetric onset of local detachment occurs, initially leaving the gap and up to 60 deg beyond that still attached. Conversely, the impact of such toroidally localized divertor perturbations on the toroidal symmetry of midplane separatrix conditions is small. This work has been funded by the U.S. Department of Energy under Early Career Award Grant DE-SC0013911, and Grant DE-FC02-04ER54698.

  19. OpenCOR: a modular and interoperable approach to computational biology

    PubMed Central

    Garny, Alan; Hunter, Peter J.

    2015-01-01

    Computational biologists have been developing standards and formats for nearly two decades, with the aim of easing the description and exchange of experimental data, mathematical models, simulation experiments, etc. One of those efforts is CellML (cellml.org), an XML-based markup language for the encoding of mathematical models. Early CellML-based environments include COR and OpenCell. However, both of those tools have limitations and were eventually replaced with OpenCOR (opencor.ws). OpenCOR is an open source modeling environment that is supported on Windows, Linux and OS X. It relies on a modular approach, which means that all of its features come in the form of plugins. Those plugins can be used to organize, edit, simulate and analyze models encoded in the CellML format. We start with an introduction to CellML and two of its early adopters, which limitations eventually led to the development of OpenCOR. We then go onto describing the general philosophy behind OpenCOR, as well as describing its openness and its development process. Next, we illustrate various aspects of OpenCOR, such as its user interface and some of the plugins that come bundled with it (e.g., its editing and simulation plugins). Finally, we discuss some of the advantages and limitations of OpenCOR before drawing some concluding remarks. PMID:25705192

  20. Percutaneous versus traditional and paraspinal posterior open approaches for treatment of thoracolumbar fractures without neurologic deficit: a meta-analysis.

    PubMed

    Sun, Xiang-Yao; Zhang, Xi-Nuo; Hai, Yong

    2017-05-01

    This study evaluated differences in outcome variables between percutaneous, traditional, and paraspinal posterior open approaches for traumatic thoracolumbar fractures without neurologic deficit. A systematic review of PubMed, Cochrane, and Embase was performed. In this meta-analysis, we conducted online searches of PubMed, Cochrane, Embase using the search terms "thoracolumbar fractures", "lumbar fractures", ''percutaneous'', "minimally invasive", ''open", "traditional", "posterior", "conventional", "pedicle screw", "sextant", and "clinical trial". The analysis was performed on individual patient data from all the studies that met the selection criteria. Clinical outcomes were expressed as risk difference for dichotomous outcomes and mean difference for continuous outcomes with 95 % confidence interval. Heterogeneity was assessed using the χ 2 test and I 2 statistics. There were 4 randomized controlled trials and 14 observational articles included in this analysis. Percutaneous approach was associated with better ODI score, less Cobb angle correction, less Cobb angle correction loss, less postoperative VBA correction, and lower infection rate compared with open approach. Percutaneous approach was also associated with shorter operative duration, longer intraoperative fluoroscopy, less postoperative VAS, and postoperative VBH% in comparison with traditional open approach. No significant difference was found in Cobb angle correction, postoperative VBA, VBA correction loss, Postoperative VBH%, VBH correction loss, and pedicle screw misplacement between percutaneous approach and open approach. There was no significant difference in operative duration, intraoperative fluoroscopy, postoperative VAS, and postoperative VBH% between percutaneous approach and paraspianl approach. The functional and the radiological outcome of percutaneous approach would be better than open approach in the long term. Although trans-muscular spatium approach belonged to open fixation methods