Sample records for early open angle

  1. [Thinking about the present primary open angle glaucoma early diagnosis concepts and methods].

    PubMed

    Ren, Zeqin

    2014-05-01

    Early diagnosis of primary open-angle glaucoma has not been clear and consistent in concepts and methods. At present, according to the pathophysiology process of optic nerve damage and its detection technology, early diagnosis on the concept still belongs to the early clinical diagnosis instead of preclinical diagnosis, and on the method depends on the fundus as morphological index combined with the visual field as functional index. The direction of early clinical diagnosis mainly lies in exploring more effective diagnosis index, rather than blindly adopt new diagnostic technology.

  2. Genetics Home Reference: early-onset glaucoma

    MedlinePlus

    ... called a syndrome. If glaucoma appears before the age of 5 without other associated abnormalities, it is called primary congenital glaucoma. Other individuals experience early onset of primary open-angle glaucoma, the most ...

  3. Progressive Decrease of Peripapillary Angioflow Vessel Density During Structural and Visual Field Progression in Early Primary Open-angle Glaucoma.

    PubMed

    Holló, Gábor

    2017-07-01

    To present a case of early primary open-angle glaucoma in which retinal nerve fiber layer thickness (RNFLT), ganglion cell complex (GCC), and visual field progression were accompanied with significant progression of peripapillary angioflow vessel density (PAFD) measured with optical coherence tomographic angiography. A 68-year-old female patient who was under topical intraocular pressure (IOP) lowering medication for 20 years for ocular hypertension of the right and preperimetric primary open-angle glaucoma of the left eye (with reproducible inferotemporal and superotemporal neuroretinal rim and RNFL loss) was prospectively imaged with the AngioVue OCT for RNFLT, GCC thickness, and PAFD, and investigated with the Octopus Normal G2 visual field test on the same days at 6-month intervals for 18 months, while the IOP of the left eye escaped from control. IOP of the left eye fluctuated between 14 and 30 mm Hg in the study period. RNFLT, GCC thickness, and peripapillary PAFD all decreased significantly (linear regression analysis, P=0.030, 0.040, and 0.020, respectively), and a significant 2.1 dB/y progression was seen for a superior visual field cluster. The RNFLT, peripapillary PAFD, and visual field of the right eye remained normal and unchanged. In our case IOP elevation, glaucomatous visual field conversion, and structural progression were accompanied with significant progressive decrease of peripapillary PAFD. The simultaneous thinning of RNFLT and GCC and decrease of peripapillary PAFD suggest that PAFD may potentially be an additional indicator of early progression in primary open-angle glaucoma.

  4. [Results of the ocular hypertension treatment study and the confocal scanning laser ophthalmoscopy ancillary study and evaluation of the heidelberg retina tomograph].

    PubMed

    Klatt, K; Schmidt, E; Scheuerle, A F

    2008-04-01

    The Ocular Hypertension Treatment Study (OHTS) has shown that analyzing changes of the optic disc configuration is superior to evaluating visual field findings for the early detection of primary open angle glaucoma. The Confocal Scanning Laser Ophthalmoscopy Ancillary Study (CSLO) is the first study to reveal that certain topographic baseline measurements of the optic disc are significantly associated with the development of primary open angle glaucoma in patients with ocular hypertension. An abnormally increased "mean height contour" value proved to be the individual parameter connected with the highest risk. The reliability of the Moorfields Regression Analysis of certain individual sectors during early detection of a primary angle glaucoma is higher than that of the global measurement. The temporal superior and inferior as well as the nasal inferior sectors have the highest positive predictive values and the largest risks in both univariate and multivariate analysis.

  5. Multifocal visual evoked potentials for early glaucoma detection.

    PubMed

    Weizer, Jennifer S; Musch, David C; Niziol, Leslie M; Khan, Naheed W

    2012-07-01

    To compare multifocal visual evoked potentials (mfVEP) with other detection methods in early open-angle glaucoma. Ten patients with suspected glaucoma and 5 with early open-angle glaucoma underwent mfVEP, standard automated perimetry (SAP), short-wave automated perimetry, frequency-doubling technology perimetry, and nerve fiber layer optical coherence tomography. Nineteen healthy control subjects underwent mfVEP and SAP for comparison. Comparisons between groups involving continuous variables were made using independent t tests; for categorical variables, Fisher's exact test was used. Monocular mfVEP cluster defects were associated with an increased SAP pattern standard deviation (P = .0195). Visual fields that showed interocular mfVEP cluster defects were more likely to also show superior quadrant nerve fiber layer thinning by OCT (P = .0152). Multifocal visual evoked potential cluster defects are associated with a functional and an anatomic measure that both relate to glaucomatous optic neuropathy. Copyright 2012, SLACK Incorporated.

  6. Myocardial infarction increases progressive visual field defects in well treated early primary open angle glaucoma--a prospective case control study.

    PubMed

    Mondal, Lakshmikanta; Baidya, Krishnapada; Choudhury, Himadri; Roy, Rupam

    2013-06-01

    The purpose of the study was to evaluate the progression of glaucomatous field damage in patients with stable primary open angle glaucoma after an attack of myocardial infarction. In this case control study, 62 open angle glaucoma patients were selected and regularly followed up. Among 62 patients, 9 had an attack of myocardial infarction. The intra-ocular pressure and visual field progression of both the groups (myocardial infarction versus no myocardial infarction) were analysed. Three (33.3%) out of 9 patients who had suffered from myocardial infarction showed progressive visual field loss whereas only 9 (16.9%) out of 53 patients who did not suffer from myocardial infarction, showed progressive field changes. Both the groups had stable target intra-ocular pressure between 14 and 16 mm Hg. Myocardial infarction may adversely influence the progression of primary open angle glaucoma which is suspected to result from ischaemia induced neuronal loss and only control of intraocular pressure is not the only solution. We have to look for other drugs that prevents ischaemia induced neuronal damage.

  7. The effectiveness of early lens extraction with intraocular lens implantation for the treatment of primary angle-closure glaucoma (EAGLE): study protocol for a randomized controlled trial.

    PubMed

    Azuara-Blanco, Augusto; Burr, Jennifer M; Cochran, Claire; Ramsay, Craig; Vale, Luke; Foster, Paul; Friedman, David; Quayyum, Zahidul; Lai, Jimmy; Nolan, Winnie; Aung, Tin; Chew, Paul; McPherson, Gladys; McDonald, Alison; Norrie, John

    2011-05-23

    Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care.EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care. EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible.The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events.A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of 1·75 mm Hg. The study will have 80% power to detect a difference of 15% in the glaucoma surgery rate. ISRCTN44464607.

  8. Angle closure glaucoma in congenital ectropion uvea.

    PubMed

    Wang, Grace M; Thuente, Daniel; Bohnsack, Brenda L

    2018-06-01

    Congenital ectropion uvea is a rare anomaly, which is associated with open, but dysplastic iridocorneal angles that cause childhood glaucoma. Herein, we present 3 cases of angle-closure glaucoma in children with congenital ectropion uvea. Three children were initially diagnosed with unilateral glaucoma secondary to congenital ectropion uvea at 7, 8 and 13 years of age. The three cases showed 360° of ectropion uvea and iris stromal atrophy in the affected eye. In one case, we have photographic documentation of progression to complete angle closure, which necessitated placement of a glaucoma drainage device 3 years after combined trabeculotomy and trabeculectomy. The 2 other cases, which presented as complete angle closure, also underwent glaucoma drainage device implantation. All three cases had early glaucoma drainage device encapsulation (within 4 months) and required additional surgery (cycloablation or trabeculectomy). Congenital ectropion uvea can be associated with angle-closure glaucoma, and placement of glaucoma drainage devices in all 3 of our cases showed early failure due to plate encapsulation. Glaucoma in congenital ectropion uvea requires attention to angle configuration and often requires multiple surgeries to obtain intraocular pressure control.

  9. Open-angle glaucoma in the Petit Basset Griffon Vendeen.

    PubMed

    Bedford, Peter G C

    2017-03-01

    To report the prevalence and clinical characteristics of an open-angle glaucoma in Petit Basset Griffon Vendeen (PBGV) dogs in the United Kingdom (UK). At breed society clinics extending over a 6-year period, 366 dogs of varying ages and both sexes were clinically examined for signs of glaucoma using slit-lamp biomicroscopy, indirect and direct ophthalmoscopy, tonometry, and gonioscopy. The prevalence of glaucoma was 10.4% (38 dogs). Clinical signs of the disease presented from 3 years of age onwards, the commonest initial feature being the elevation of intraocular pressure (IOP) in 15 dogs (39.4%). In addition to elevated IOP, another 13 dogs (34.2%) presented with other features of glaucoma, some with lens subluxation and globe enlargement and all with possible or known vision defects. In the remaining 10 dogs (26.3%), phacodonesis or lens subluxation was observed before subsequent elevation of IOP. High prevalence and similarity to the primary open-angle glaucoma (POAG) seen in the Beagle and Elkhound breeds indicate that an open-angle glaucoma is present in the PBGV in the UK and that this disease may be genetically determined in this breed. Although increased IOP is the commonest early diagnostic feature, lens instability prior to an increase in IOP may be part of the clinical picture. © 2016 American College of Veterinary Ophthalmologists.

  10. Linkage analysis excludes the glaucoma locus on 1q from involvement in autosomal dominant glaucoma with iris hypoplasia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heon, E.; Sheth, B.P.; Kalenak, J.W.

    1994-09-01

    Genetic factors have been implicated in a variety of types of glaucoma including primary open-angle glaucoma, infantile glaucoma, pigmentary glaucoma, and juvenile open-angle glaucoma. We previously mapped the disease-causing gene for one type of juvenile open angle glaucoma to chromosome 1q21-31. Weatherill and Hart (1969) and Pearce (1983) each noted the association of iris hypoplasia and early-onset autosomal dominant glaucoma. We recently had the opportunity to study a large family (12 affected members) with this phenotype. Affected individuals developed glaucoma at an average age of 30 years. These patients also have a strikingly underdeveloped iris stroma which causes a peculiarmore » eye color. Linkage analysis was able to completely exclude the 1q glaucoma locus from involvement in the disorder that affects this family. A complete clinical description of the family and linkage results at additional candidate loci will be presented.« less

  11. Stationary Digital Tomosynthesis System for Early Detection of Breast Tumors

    DTIC Science & Technology

    2012-05-01

    Vol. 5745. 2005. 14. Y. Zhang, et al., A comparative study of limited-angle cone-beam reconstruction methods 505 for breast tomosynthesis. Med...opening angl em integratio designed line nia Dimension determine the try calibration th the detector ain is sent fro between XC urce not fou here...screening mammography. AJR, 2007. 189: p. 616. 12. P. Baldelli, et al., A prototype of a quasi-monochromatic system for mammography applications . Phys

  12. The effectiveness of early lens extraction with intraocular lens implantation for the treatment of primary angle-closure glaucoma (EAGLE): study protocol for a randomized controlled trial

    PubMed Central

    2011-01-01

    Background Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care. EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care. Methods/Design EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible. The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events. A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of 1·75 mm Hg. The study will have 80% power to detect a difference of 15% in the glaucoma surgery rate. Trial Registration: ISRCTN44464607. PMID:21605352

  13. Glaucoma

    MedlinePlus

    Open-angle glaucoma; Chronic glaucoma; Chronic open-angle glaucoma; Primary open-angle glaucoma; Closed-angle glaucoma; Narrow-angle glaucoma; Angle-closure glaucoma; Acute glaucoma; Secondary glaucoma; Congenital glaucoma; Vision ...

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geltman, S.

    Recent measurements on CO{sub 2}-laser-assisted electron-atom collisions have shown large inconsistencies with the Kroll-Watson formula for small-angle scattering. We have carried out a detailed study to compare the predictions of Kroll-Watson theory (for both single and multimode fields) with those of conventional perturbation theory for stimulated free-free transitions. It is found that for {ital E}{sub 0}/2{omega}{sup 2}{lt}1, where perturbation theory is valid, there are large differences with the Kroll-Watson theory. Comparisons of experimental variations with respect to scattering angle and electron energy show much better agreement with perturbation theory than with Kroll-Watson theory. A study of the angular variations inmore » perturbation theory shows that use of the {open_quote}{open_quote}outgoing{close_quote}{close_quote} wave final state gives much better agreement with experiment than does the {open_quote}{open_quote}ingoing{close_quote}{close_quote} wave final state, which is different from the choice made in early bremsstrahlung theory. {copyright} {ital 1996 The American Physical Society.}« less

  15. Minimally Invasive and Open Distal Chevron Osteotomy for Mild to Moderate Hallux Valgus.

    PubMed

    Brogan, Kit; Lindisfarne, Edward; Akehurst, Harold; Farook, Usama; Shrier, Will; Palmer, Simon

    2016-11-01

    Minimally invasive surgical (MIS) techniques are increasingly being used in foot and ankle surgery but it is important that they are adopted only once they have been shown to be equivalent or superior to open techniques. We believe that the main advantages of MIS are found in the early postoperative period, but in order to adopt it as a technique longer-term studies are required. The aim of this study was to compare the 2-year outcomes of a third-generation MIS distal chevron osteotomy with a comparable traditional open distal chevron osteotomy for mild-moderate hallux valgus. Our null hypothesis was that the 2 techniques would yield equivalent clinical and radiographic results at 2 years. This was a retrospective cohort study. Eighty-one consecutive feet (49 MIS and 32 open distal chevron osteotomies) were followed up for a minimum 24 months (range 24-58). All patients were clinically assessed using the Manchester-Oxford Foot Questionnaire. Radiographic measures included hallux valgus angle, the intermetatarsal angle, hallux interphalangeal angle, metatarsal phalangeal joint angle, distal metatarsal articular angle, tibial sesamoid position, shape of the first metatarsal head, and plantar offset. Statistical analysis was done using Student t test or Wilcoxon rank-sum test for continuous data and Pearson chi-square test for categorical data. Clinical and radiologic postoperative scores in all domains were substantially improved in both groups (P < .001), but there was no statistically significant difference in improvement of any domain between open and MIS groups (P > .05). There were no significant differences in complications between the 2 groups ( > .5). The midterm results of this third-generation technique show that it was a safe procedure with good clinical outcomes and comparable to traditional open techniques for symptomatic mild-moderate hallux valgus. Level III, retrospective comparative study. © The Author(s) 2016.

  16. Early Clinical Results of a Novel Ab Interno Gel Stent for the Surgical Treatment of Open-angle Glaucoma.

    PubMed

    Sheybani, Arsham; Dick, H Burkhard; Ahmed, Iqbal I K

    2016-07-01

    To evaluate the intraocular pressure (IOP) lowering effect of the XEN140 microfistula gel stent implant for the surgical treatment of open-angle glaucoma. Forty-nine eyes of 49 patients with an IOP>18 mm Hg and ≤35 mm Hg were studied in a prospective nonrandomized multicenter cohort trial of the surgical implantation of the XEN140 implant in patients with open-angle glaucoma. Complete success was defined as a postoperative IOP≤18 mm Hg with ≥20% reduction in IOP at 12 months without any glaucoma medications. Failure was defined as vision loss of light perceptions vision or worse, need for additional glaucoma surgery, or <20% reduction of IOP from baseline. The average age was 64.3 (28.1 to 86.9) years old. Twenty-one eyes had prior failed trabeculectomy with mitomycin C surgery. IOP at 12 months decreased from a mean of 23.1 (±4.1) mm Hg to 14.7 (±3.7) mm Hg for a 36.4% reduction in IOP from baseline. The number of patients at 12 months who achieved an IOP≤18 mm Hg and ≥20% reduction in IOP was 40 (89%). The number of patients who achieved an IOP≤18 mm Hg and ≥20% reduction in IOP without antiglaucoma medications was 18 (40%). The XEN140 gel stent lowers IOP with few complications when implanted for the surgical treatment of open-angle glaucoma.

  17. Dermatoglyphic characters and physique: a correlation study.

    PubMed

    Rothhammer, F; Llop, E; Neel, J V

    1982-01-01

    The association of anthropometrics, particularly hand measurements, with dermatoglyphic characters is quantified. Children with square hands exhibit higher main line indices, a-b ridge counts, and more open atd angles. Adults with broader hands have more arches. Taller individuals with larger hands present higher a-b ridge counts and leaner subjects with long narrow hands, closer atd angles. The correlation of physique and dermatoglyphics is small but if verified, suggests that at early fetal stages, factors responsible for the establishment of dermatoglyphic patterns interact with genetic determinants of adult shape that are already active.

  18. Evaluation of retinal ganglion cell function after intraocular pressure reduction measured by pattern electroretinogram in patients with primary open-angle glaucoma.

    PubMed

    Karaśkiewicz, Joanna; Penkala, Krzysztof; Mularczyk, Maciej; Lubiński, Wojciech

    2017-04-01

    To evaluate retinal ganglion cell (RGC) function after intraocular pressure (IOP) reduction measured by pattern electroretinogram (PERG) in patients with newly diagnosed, non-treated preperimetric and early stages of primary open-angle glaucoma (POAG). Twenty-four eyes from 24 patients with POAG: 11 eyes with preperimetric glaucoma and 13 eyes with early glaucoma received Ganfort ® (bimatoprost + timolol) once a day for a period of 1 month. Before and after the treatment, following measurements were analyzed: IOP, mean ocular perfusion pressure (MOPP), peak time of P50 and amplitude of P50 and N95 waves in PERG (ISCEV standard 2012). Correlations between PERG P50 and N95 waves, IOP and MOPP were calculated. After therapy, IOP significantly decreased in all eyes, on average 31%. Significant increase in MOPP in all eyes on average 14% was detected. PERG amplitude of P50 and N95 waves increased in 75 and 79% eyes, respectively, on average P50 by 28% and N95 by 38%. There were no significant interactions between the change of PERG parameters in time and stage of glaucoma. Significant IOP-lowering therapy can improve RGC function measured by PERG, in patients with preperimetric and early stages of POAG.

  19. Diagnostic capability of scanning laser polarimetry with variable cornea compensator in Indian patients with early primary open-angle glaucoma.

    PubMed

    Parikh, Rajul S; Parikh, Shefali R; Kumar, Rajesh S; Prabakaran, S; Babu, J Gansesh; Thomas, Ravi

    2008-07-01

    To evaluate the diagnostic ability of scanning laser polarimetry (GDx variable corneal compensator [VCC]) for early glaucoma in Asian Indian eyes. Cross-sectional observational study. Two groups of patients (early glaucoma and normal) who satisfied the inclusion and exclusion criteria were included. Early glaucoma was diagnosed in presence of open angles, characteristic glaucomatous optic disc changes correlating with the visual field (VF) on automated perimetry (VF defect fulfilling at least 2 of 3 Anderson and Patella's criteria with mean deviation >or= -6 decibels). Normal subjects had visual acuity >or= 20/30 and intraocular pressure < 22 mmHg, with a normal optic disc and fields and no ocular abnormality. All patients underwent complete ophthalmic evaluation, including VF examination (24-2/30-2 Swedish interactive threshold algorithm standard program) and imaging with GDx VCC. Sensitivity, specificity, positive predictive value and negative predictive value, area under the receiving operating characteristic curve, and likelihood ratios (LRs) were calculated for various GDx VCC parameters. Seventy-four eyes (74 patients) with early glaucoma and 104 eyes (104 normal subjects) were enrolled. TSNIT Std Dev (temporal-superior-nasal-inferior-temporal standard deviation) had the best combination of sensitivity and specificity-61.3 and 95.2, respectively-followed by nerve fiber index score > 50 (sensitivity, 52.7%; specificity, 99%). Nerve fiber index score > 50 had positive and negative predictive values of 74.3% and 97.6%, respectively, for an assumed glaucoma prevalence of 5%. Nerve fiber index score > 50 had a positive LR (+LR) of 54.8 for early glaucoma. GDx VCC has moderate sensitivity, with high specificity, in the diagnosis of early glaucoma. The high +LR for the nerve fiber index score can provide valuable diagnostic information for individual patients.

  20. Mitral Valve Stenosis after Open Repair Surgery for Non-rheumatic Mitral Valve Regurgitation: A Review.

    PubMed

    Shabsigh, Muhammad; Lawrence, Cassidy; Rosero-Britton, Byron R; Kumar, Nicolas; Kimura, Satoshi; Durda, Michael Andrew; Essandoh, Michael

    2016-01-01

    Mitral stenosis (MS) after mitral valve (MV) repair is a slowly progressive condition, usually detected many years after the index MV surgery. It is defined as a mean transmitral pressure gradient (TMPG) >5 mmHg or a mitral valve area (MVA) <1.5 cm(2). Pannus formation around the mitral annulus or extending to the mitral leaflets is suggested as the main mechanism for developing delayed MS after MV repair. On the other hand, early stenosis is thought to be a direct result of an undersized annuloplasty ring. Furthermore, in MS following ischemic mitral regurgitation (MR) repair, subvalvular tethering is the hypothesized pathophysiology. MS after MV repair has an incidence of 9-54%. Several factors have been associated with a higher risk for developing MS after MV repair, including the use of flexible Duran annuloplasty rings versus rigid Carpentier-Edwards rings, complete annuloplasty rings versus partial bands, small versus large anterior leaflet opening angle, and anterior leaflet tip opening length. Intraoperative echocardiography can measure the anterior leaflet opening angle, the anterior leaflet tip opening dimension, the MVA and the mean TMPG, and may help identify patients at risk for developing MS after MV repair.

  1. Mitral Valve Stenosis after Open Repair Surgery for Non-rheumatic Mitral Valve Regurgitation: A Review

    PubMed Central

    Shabsigh, Muhammad; Lawrence, Cassidy; Rosero-Britton, Byron R.; Kumar, Nicolas; Kimura, Satoshi; Durda, Michael Andrew; Essandoh, Michael

    2016-01-01

    Mitral stenosis (MS) after mitral valve (MV) repair is a slowly progressive condition, usually detected many years after the index MV surgery. It is defined as a mean transmitral pressure gradient (TMPG) >5 mmHg or a mitral valve area (MVA) <1.5 cm2. Pannus formation around the mitral annulus or extending to the mitral leaflets is suggested as the main mechanism for developing delayed MS after MV repair. On the other hand, early stenosis is thought to be a direct result of an undersized annuloplasty ring. Furthermore, in MS following ischemic mitral regurgitation (MR) repair, subvalvular tethering is the hypothesized pathophysiology. MS after MV repair has an incidence of 9–54%. Several factors have been associated with a higher risk for developing MS after MV repair, including the use of flexible Duran annuloplasty rings versus rigid Carpentier–Edwards rings, complete annuloplasty rings versus partial bands, small versus large anterior leaflet opening angle, and anterior leaflet tip opening length. Intraoperative echocardiography can measure the anterior leaflet opening angle, the anterior leaflet tip opening dimension, the MVA and the mean TMPG, and may help identify patients at risk for developing MS after MV repair. PMID:27148540

  2. Evaluation of blotchy pigments in the anterior chamber angle as a sign of angle closure

    PubMed Central

    Rao, Harsha L; Mungale, Sachin C; Kumbar, Tukaram; Parikh, Rajul S; Garudadri, Chandra S

    2012-01-01

    Background: Blotchy pigments in the anterior chamber (AC) angle are considered diagnostic of primary angle closure (PAC). But there are no reports either on the prevalence of blotchy pigments in AC angles or the validity of this sign. Aims: To determine the prevalence of blotchy pigments in AC angles and to evaluate their relationship with glaucomatous optic neuropathy (GON) in eyes with occludable angles. Setting and Design: Cross-sectional, comparative study. Materials and Methods: Gonioscopy was performed in 1001 eyes of 526 subjects (245 eyes of 148 consecutive, occludable angle subjects and 756 eyes of 378 non-consecutive, open angle subjects), above 35 years of age. Quadrant-wise location of blotchy pigments was documented. Statistical Analysis: Odds of blotchy pigments in occludable angles against that in open angles were evaluated. Relationship of GON with blotchy pigments in occludable angle eyes was evaluated using a multivariate model. Results: Prevalence of blotchy pigments in occludable angles was 28.6% (95% CI, 22.9-34.3) and in open angles was 4.7% (95% CI, 3.2-6.3). Blotchy pigments were more frequently seen in inferior (16%) and superior quadrants (15%) of occludable angles, and inferior quadrant of open angles (4%). Odds of superior quadrant blotchy pigments in occludable angles were 33 times that in open angles. GON was seen in 107 occludable angle eyes. Blotchy pigments were not significantly associated with GON (odds ratio = 0.5; P = 0.1). Conclusions: Blotchy pigments were seen in 28.6% of occludable angle eyes and 4.7% of open angles eyes. Presence of blotchy pigments in the superior quadrant is more common in occludable angles. Presence of GON in occludable angle eyes was not associated with blotchy pigments. PMID:23202393

  3. EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability

    PubMed Central

    Chan, Jessica E; Netland, Peter A

    2015-01-01

    Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, complications associated with the procedure have motivated the development of alternative techniques and devices, including the EX-PRESS Glaucoma Filtration Device. This review describes the efficacy, safety, complication rates, and potential advantages and disadvantages of the EX-PRESS Glaucoma Filtration Device. EX-PRESS implantation is technically simpler compared with that of trabeculectomy, with fewer surgical steps. Vision recovery has been more rapid after EX-PRESS implantation compared with trabeculectomy. Intraocular pressure variation is lower during the early postoperative period, indicating a more predictable procedure. While efficacy of the EX-PRESS implant has been comparable to trabeculectomy, postoperative complications appear less common after EX-PRESS implantation compared with trabeculectomy. The EX-PRESS Glaucoma Filtration Device appears to be safe and effective in the surgical management of open-angle glaucoma. PMID:26366105

  4. Glaucoma: Symptoms and Causes

    MedlinePlus

    ... damage. The types of glaucoma include the following: Open-angle glaucoma Open-angle glaucoma is the most common form of ... angle formed by the cornea and iris remains open, but the trabecular meshwork is partially blocked. This ...

  5. [Basic and clinical studies of pressure-independent damaging factors of open angle glaucoma].

    PubMed

    Araie, Makoto

    2011-03-01

    Pathogenesis of open-angle glaucoma involves both pressure-dependent damaging factors and pressure-independent damaging factors. The high prevalence of open-angle glaucoma with normal pressure (normal-tension glaucoma) in Japan implies that treatment of pressure-independent damaging factors in Japanese open-angle glaucoma patients is of importance. In an attempt to investigate the roles of pressure-independent damaging factors in open-angle glaucoma, we carried out basic and clinical studies and obtained the following results. 1. The rate of deterioration of visual field after trabeculectomy in normal tension glaucoma patients with post-operative intraocular pressure (IOP) of 10 mmHg was found to be -0.25 dB/year of mean deviation (MD), suggesting that contribution of pressure-independent damaging factors to the deterioration of MD in open-angle glaucoma is around -0.25 dB/year of mean deviation (MD). 2. Experiments using isolated purified cultured retinal ganglion cells (RGCs) indicated that calcium-channel blockers and some of antiglaucoma drugs showed neuroprotective effects on RGCs at concentrations of 0.01 microM or higher. 3. In mice, damage to RGCs resulted in secondary degeneration of neurons and activation of glial cells in the lateral geniculate nucleous (LGN) and superior colliculus, and these secondary changes in the central nervous system (CNS) due to RGC damage was partly ameliorated by systemic administration of memantine. 4. Mice experimental high IOP glaucoma models could be established using laser irradiation of the limbal area, and the usefulness of Tonolab in IOP measurements of mice eye was confirmed. 5. Monkey experimental high IOP glaucoma models revealed that in the glaucomatous optic nerve head vaso-constrictive reactions to an alpha-1 agonist was abolished, while vasodilative reaction to a prostaglandin FP receptor agonist was retained. 6. In monkeys with experimental high IOP glaucoma, secondary damage to neurons in the LGN and the glial reaction to it were also found, similar to the mice experiments. In living monkeys the glial reaction in the LGN could be observed by means of positron emission tomography. 7. In the LGN of monkeys with experimental high IOP glaucoma, the M-cell system was preferentially damaged in the early stage, while in the later stages both the M- and P-cell systems were damaged. 8. In a single-instituted prospective double-blinded clinical trial, oral administration of nilvadipine at 4 mg/day, a DHP calcium-channel blocker, was found to significantly retard the visual field progression in normal tension glaucoma patients over 3 years, while significantly increasing the choroidal and optic nerve blood flow by about 35%. 9. A multi-instituted prospective double-blinded clinical trial in normal tension glaucoma patients revealed that the rate of MD deterioration under monotherapy with either topical nipradilol or timolol was around -0.05 dB/year, thought to be considerably slower than -0.25 dB/year, the commonly estimated rate of MD deterioration by pressure-independent damaging factors. The current results indicate the possibility of treatment of pressure-independent damaging factors of open-angle glaucoma in Japanese open-angle glaucoma patients with oral nilvadipine and topical anti-glaucoma agents.

  6. Comparison of Pattern Electroretinography and Optical Coherence Tomography Parameters in Patients with Primary Open-Angle Glaucoma and Ocular Hypertension

    PubMed Central

    Tiryaki Demir, Semra; Oba, Mehmet Ersin; Erdoğan, Ezgi Tuna; Odabaşı, Mahmut; Dirim, Ayşe Burcu; Demir, Mehmet; Can, Efe; Kara, Orhan; Yekta Şendül, Selam

    2015-01-01

    Objectives: To investigate the correlation of visual field (VF), pattern electroretinography (PERG) and Fourier domain optical coherence tomography (FD-OCT) results in patients with ocular hypertension (OHT) and early primary open-angle glaucoma (POAG). Materials and Methods: The study included 72 eyes of 37 patients with early POAG, 76 eyes of 38 patients with OHT, and 60 eyes of 30 controls. All subjects underwent full ophthalmologic examination, VF assessment with 24-2 Humphrey standard automated perimetry (Swedish Interactive Thresholding Algorithm (SITA)-Standard), retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) thickness measurement with FD-OCT, and PERG P50 and N95 wave latency and amplitude measurements with electroretinography (Nihon Kohden). Results: With the exception of the nasal quadrant, all GCC parameters and RNFL results were significantly lower in the POAG group compared to the OHT and control groups. There was no statistically significant difference between the OHT and control group. PERG amplitudes were lower in the POAG and OHT groups than in the control group. Reduction in N95 amplitude was greater than that of P50 amplitude. No difference was detected in PERG latencies among groups. GCC was significantly correlated with VF and RNFL in the POAG group. Conclusion: Significant thinning of the GCC and RNFL occurs in addition to VF pathologies in patients with early POAG, and these examinations should be concomitantly evaluated. During diagnostic assessment of patients with early POAG, GCC and RNFL analysis by FD-OCT are highly effective. GCC is as reliable as RNLF in the early diagnosis of glaucoma and there is a highly significant correlation between them. Dysfunction of ganglion cells in patients with OHT may be detected earlier using PERG amplitude analysis. PMID:27800239

  7. Open-angle glaucoma in patients with diabetic retinopathy at the Puerto Rico Medical Center.

    PubMed

    Cruz-lñigo, Yousef; Izquierdo, Natalio J; García, Omar; Pérez, Raúl

    2012-01-01

    The association of open-angle glaucoma (OAG) with diabetes mellitus remains controversial. We report on the frequency of open-angle glaucoma in patients having diabetic retinopathy in a population of the Puerto Rico Medical Center. A cross-sectional study of 1,442 patients was done. Only the chart of patients 40 years-of-age and older, with a diagnosis of diabetic retinopathy and/or open-angle glaucoma were included. Descriptive analysis was done. Unadjusted and gender-adjusted logistic regression analyses were used to estimate risk of developing open-angle glaucoma in patients with diabetic retinopathy for each subsequent decade. 1,040 patients were diagnosed with diabetic retinopathy from July 1, 2004 to June 30, 2009. Also, 402 patients were diagnosed with open-angle glaucoma from July 1, 2007 to June 30, 2009. Of the 1,040 patients with diabetic retinopathy, 64 patients (6.15%) also had OAG. According to our gender-adjusted logistic regression analysis the estimated risk of developing open-angle glaucoma for patients 40 years-of-age with diabetic retinopathy increased for each subsequent decade until the seventh decade, odds ratio = 5.07 (95% confidence interval: 1.62-15.86). Thereafter, it decreased, odds ratio = 2.07 (95% confidence interval: 0.36-11.82). Our findings suggest that Puerto Rico patients between 40 to 79 years of age with diabetic retinopathy have an increased risk of developing open-angle glaucoma with each subsequent decade. Screening for open-angle glaucoma in patients with diabetic retinopathy is of utmost importance in the aging Puerto Rico population to prevent blindness.

  8. Evaluation of the anterior chamber angle in Asian Indian eyes by ultrasound biomicroscopy and gonioscopy.

    PubMed

    Kaushik, Sushmita; Jain, Rajeev; Pandav, Surinder Singh; Gupta, Amod

    2006-09-01

    To compare the ultrasound biomicroscopic measurement of the anterior chamber angle in Asian Indian eyes, with the angle width estimated by gonioscopy. Patients with open and closed angles attending a glaucoma clinic were recruited for the study. Temporal quadrants of the angles of patients were categorized by gonioscopy as Grade 0 to Grade 4, using Shaffer's classification. These angles were quantified by ultrasound biomicroscopy (UBM) using the following biometric characteristics: Angle opening distance at 250 micro (AOD 250) and 500 micro (AOD 500) from the scleral spur and trabecular meshwork-ciliary process distance (TCPD). The angles were further segregated as "narrow angles" (Schaffer's Grade 2 or less) and "open angles" (Schaffer's Grade 3 and 4). The UBM measurements were computed in each case and analyzed in relation to the gonioscopic angle evaluation. One hundred and sixty three eyes of 163 patients were analyzed. One hundred and six eyes had "narrow angles" and 57 eyes had "open angles" on gonioscopy. There was a significant difference among the mean UBM measurements of each angle grade estimated by gonioscopy (P < 0.001). The Pearson correlation coefficient between all UBM parameters and gonioscopy grades was significant at the 0.01 level. The mean AOD 250, AOD 500 and TCPD in narrow angles were 58+/-49 micro, 102+/-84 micro and 653+/-124 respectively, while it was 176+/-47 micro, 291+/-62 micro and 883+/-94 micro in eyes with open angles (P < 0.001) respectively. The angle width estimated by gonioscopy correlated significantly with the angle dimensions measured by UBM. Gonioscopy, though a subjective test, is a reliable method for estimation of the angle width.

  9. Lamina cribrosa position and Bruch's membrane opening differences between anterior ischemic optic neuropathy and open-angle glaucoma.

    PubMed

    Rebolleda, Gema; Pérez-Sarriegui, Ane; Díez-Álvarez, Laura; De Juan, Victoria; Muñoz-Negrete, Francisco J

    2018-06-01

    To compare the optic nerve head morphology among primary open-angle glaucoma, non-arteritic anterior ischemic optic neuropathy eyes, their fellow healthy eyes and control eyes, using spectral-domain optical coherence tomography with enhanced depth imaging. Observational cross-sectional study including 88 eyes of 68 patients. In this study, 23 non-arteritic anterior ischemic optic neuropathy eyes, 17 fellow unaffected eyes, 25 primary open-angle glaucoma eyes, and 23 age-matched control eyes were included. Peripapillary retinal nerve fiber layer thickness and optic disk area were evaluated. Bruch's membrane opening diameter, optic cup depth, anterior lamina cribrosa depth, and prelaminar tissue thickness were assessed. Non-arteritic anterior ischemic optic neuropathy and primary open-angle glaucoma eyes had similar visual field mean deviation and peripapillary retinal nerve fiber layer thickness (P = 0.6 and P = 0.56, respectively). Bruch's membrane opening diameter was significantly larger in primary open-angle glaucoma eyes than in control eyes (P = 0.02). Lamina cribrosa and disk cup were deeper in eyes with primary open-angle glaucoma than both control and non-arteritic anterior ischemic optic neuropathy eyes (P < 0.001). Prelaminar tissue thickness was significantly thinner in primary open-angle glaucoma eyes than in non-arteritic anterior ischemic optic neuropathy eyes (P < 0.001). Lamina cribrosa was shallower in both non-arteritic anterior ischemic optic neuropathy and unaffected fellow eyes compared to healthy eyes (P < 0.001 and P = 0.04, respectively). No differences were found in the optic disk area. A forward lamina cribrosa placement and not a smaller disk could be involved in the pathogenesis of non-arteritic anterior ischemic optic neuropathy. A significantly larger Bruch's membrane opening diameter was found in primary open-angle glaucoma eyes compared with control eyes. This issue has clinical implications because Bruch's membrane opening has been considered a stable reference for disk-related measures.

  10. [Dry eye syndrome in patients with primary open-angle glaucoma].

    PubMed

    Boyko, E V; Simakova, I L; Yakushev, D Yu; Ignat'ev, S A; Alekseev, I B; Mel'nikova, N V; Alyab'ev, M V; Mal'tsev, D S

    2015-01-01

    to determine the frequency and severity of dry eye syndrome (DES) in primary open-angle glaucoma (POAG) patients that are newly diagnosed or already receiving beta blocker instillation therapy. A total of 127 patients (190 eyes) with POAG were divided into two groups. Group 1 included 55 newly diagnosed patients (88 eyes), group 2-72 POAG patients (102 eyes) instilling timolol 0.5% twice daily into the affected eye. The control group included 20 patients (40 eyes) aged 60-88 years (73.6 ± 9.2 years on average) with early age-related cataract. DES was found in 69 POAG patients (79%) who was just starting their topical hypotensive therapy and 85 of those (84%) under treatment (p = 0.39). One should take into account when prescribing ocular hypotensive therapy that newly diagnosed POAG patients usually already suffer from a dry eye. The use of topical beta blockers that contain preservatives exacerbates dry eye signs and symptoms in these patients.

  11. Development and initial validation of the Classification of Early-Onset Scoliosis (C-EOS).

    PubMed

    Williams, Brendan A; Matsumoto, Hiroko; McCalla, Daren J; Akbarnia, Behrooz A; Blakemore, Laurel C; Betz, Randal R; Flynn, John M; Johnston, Charles E; McCarthy, Richard E; Roye, David P; Skaggs, David L; Smith, John T; Snyder, Brian D; Sponseller, Paul D; Sturm, Peter F; Thompson, George H; Yazici, Muharrem; Vitale, Michael G

    2014-08-20

    Early-onset scoliosis is a heterogeneous condition, with highly variable manifestations and natural history. No standardized classification system exists to describe and group patients, to guide optimal care, or to prognosticate outcomes within this population. A classification system for early-onset scoliosis is thus a necessary prerequisite to the timely evolution of care of these patients. Fifteen experienced surgeons participated in a nominal group technique designed to achieve a consensus-based classification system for early-onset scoliosis. A comprehensive list of factors important in managing early-onset scoliosis was generated using a standardized literature review, semi-structured interviews, and open forum discussion. Three group meetings and two rounds of surveying guided the selection of classification components, subgroupings, and cut-points. Initial validation of the system was conducted using an interobserver reliability assessment based on the classification of a series of thirty cases. Nominal group technique was used to identify three core variables (major curve angle, etiology, and kyphosis) with high group content validity scores. Age and curve progression ranked slightly lower. Participants evaluated the cases of thirty patients with early-onset scoliosis for reliability testing. The mean kappa value for etiology (0.64) was substantial, while the mean kappa values for major curve angle (0.95) and kyphosis (0.93) indicated almost perfect agreement. The final classification consisted of a continuous age prefix, etiology (congenital or structural, neuromuscular, syndromic, and idiopathic), major curve angle (1, 2, 3, or 4), and kyphosis (-, N, or +) variables, and an optional progression modifier (P0, P1, or P2). Utilizing formal consensus-building methods in a large group of surgeons experienced in treating early-onset scoliosis, a novel classification system for early-onset scoliosis was developed with all core components demonstrating substantial to excellent interobserver reliability. This classification system will serve as a foundation to guide ongoing research efforts and standardize communication in the clinical setting. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  12. On the evolution of jet energy and opening angle in strongly coupled plasma

    NASA Astrophysics Data System (ADS)

    Chesler, Paul M.; Rajagopal, Krishna

    2016-05-01

    We calculate how the energy and the opening angle of jets in {N} = 4 SYM theory evolve as they propagate through the strongly coupled plasma of that theory. We define the rate of energy loss dE jet /dx and the jet opening angle in a straightforward fashion directly in the gauge theory before calculating both holographically, in the dual gravitational description. In this way, we rederive the previously known result for dE jet /dx without the need to introduce a finite slab of plasma. We obtain a striking relationship between the initial opening angle of the jet, which is to say the opening angle that it would have had if it had found itself in vacuum instead of in plasma, and the thermalization distance of the jet. Via this relationship, we show that {N} = 4 SYM jets with any initial energy that have the same initial opening angle and the same trajectory through the plasma experience the same fractional energy loss. We also provide an expansion that describes how the opening angle of the {N} = 4 SYM jets increases slowly as they lose energy, over the fraction of their lifetime when their fractional energy loss is not yet large. We close by looking ahead toward potential qualitative lessons from our results for QCD jets produced in heavy collisions and propagating through quark-gluon plasma.

  13. On the evolution of jet energy and opening angle in strongly coupled plasma

    DOE PAGES

    Chesler, Paul M.; Rajagopal, Krishna

    2016-05-17

    We calculate how the energy and the opening angle of jets in N = 4SYM theory evolve as they propagate through the strongly coupled plasma of that theory. We define the rate of energy loss dE jet/dx and the jet opening angle in a straightforward fashion directly in the gauge theory before calculating both holographically, in the dual gravitational description. In this way, we rederive the previously known result for dE jet/dx without the need to introduce a finite slab of plasma. We obtain a striking relationship between the initial opening angle of the jet, which is to say themore » opening angle that it would have had if it had found itself in vacuum instead of in plasma, and the thermalization distance of the jet. Via this relationship, we show that N = 4SYM jets with any initial energy that have the same initial opening angle and the same trajectory through the plasma experience the same fractional energy loss. We also provide an expansion that describes how the opening angle of the N = 4SYM jets increases slowly as they lose energy, over the fraction of their lifetime when their fractional energy loss is not yet large. In conclusion, we close by looking ahead toward potential qualitative lessons from our results for QCD jets produced in heavy collisions and propagating through quark-gluon plasma.« less

  14. Anterior segment parameters as predictors of intraocular pressure reduction after phacoemulsification in eyes with open-angle glaucoma.

    PubMed

    Hsia, Yen C; Moghimi, Sasan; Coh, Paul; Chen, Rebecca; Masis, Marisse; Lin, Shan C

    2017-07-01

    To evaluate intraocular pressure (IOP) change after cataract surgery in eyes with open-angle glaucoma (OAG) and its relationship to angle and anterior segment parameters measured by anterior segment optical coherence tomography (AS-OCT). University of California, San Francisco, California, USA. Prospective case series. Eyes were placed into a narrow-angle group or open-angle group based on gonioscopy grading. Biometric parameters were measured using AS-OCT (Visante) preoperatively, and IOP 4 months after surgery was obtained. The IOP change and its relationship to AS-OCT parameters were evaluated. Eighty-one eyes of 69 patients were enrolled. The mean age of the patients was 76.8 years. The preoperative IOP was 15.02 mm Hg on 1.89 glaucoma medications. The average mean deviation of preoperative visual field was -4.58 dB. The mean IOP reduction was 2.1 mm Hg (12.8%) from a preoperative mean of 15.0 mm Hg. The IOP reduction was significantly greater in eyes with narrow angles than in eyes with open angles (20.4% versus 8.0%) (P = .002). In multivariate analysis, preoperative IOP (β = -0.53, P < .001, R 2  = 0.40), angle-opening distance at 500 mm (β = 5.83, P = .02, R 2  = 0.45), angle-opening distance at 750 mm (β = 5.82, P = .001, R 2  = 0.52), and lens vault (β = -0.002, P = .009, R 2  = 0.47) were associated with IOP reduction postoperatively. In eyes with OAG, IOP reduction after cataract surgery was greater in eyes with narrower angles. Preoperative IOP, angle-opening distance, and lens vault were predictors for IOP reduction. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. A Generalized Maxwell Model for Creep Behavior of Artery Opening Angle

    PubMed Central

    Zhang, W.; Guo, X.; Kassab, G. S.

    2009-01-01

    An artery ring springs open into a sector after a radial cut. The opening angle characterizes the residual strain in the unloaded state, which is fundamental to understanding stress and strain in the vessel wall. A recent study revealed that the opening angle decreases with time if the artery is cut from the loaded state, while it increases if the cut is made from the no-load state due to viscoelasticity. In both cases, the opening angle approaches the same value in 3 hours. This implies that the characteristic relaxation time is about 10,000 sec. Here, the creep function of a generalized Maxwell model (a spring in series with six Voigt bodies) is used to predict the temporal change of opening angle in multiple time scales. It is demonstrated that the theoretical model captures the salient features of the experimental results. The proposed creep function may be extended to study the viscoelastic response of blood vessels under various loading conditions. PMID:19045526

  16. Starflo glaucoma implant: early experience in Hungary

    PubMed Central

    István, Cseke; Péter, Vámosi; Mária, Bausz

    2016-01-01

    Aim: To present the early experience with the implantation technique, safety and efficiency of STARflo™ device for open angle glaucoma (OAG). Methods: referring intra- and postoperative clinical experience with a series of seven cases in three glaucoma centers in Hungary. Results: No intraoperative complications were observed. Postoperative inflammatory signs disappeared rapidly. The mean IOP reduction was from 27,6 ± 5,0 mmHg to 18,9±3,4 mmHg (32% reduction/ patient) at six months postoperatively. Conclusion: STARflo™ implant was safe and (except for one case with neovascular glaucoma) effective in our cases. The learning curve for experienced anterior segment surgeons was short. PMID:27220226

  17. Velocity and size of droplets in dense region of diesel fuel spray on transient needle opening condition

    NASA Astrophysics Data System (ADS)

    Ueki, Hironobu; Ishida, Masahiro; Sakaguchi, Daisaku

    2005-06-01

    In order to investigate the effect of transient needle opening on early stage of spray behavior, simultaneous measurements of velocity and size of droplet were conducted by a newly developed laser 2-focus velocimeter (L2F). The micro-scale probe of the L2F was consisted of two foci with a distance of 36 µm. The tested nozzle had a single hole with a diameter of 0.2 mm. The measurements of injection pressure, needle lift, and crank angle were synchronized with the spray measurement by the L2F at the position 10 mm downstream from the nozzle exit. It has been clearly shown that the velocity and size of droplet increase with needle valve opening and that the probability density distribution of droplet size can be fitted to the Nukiyama-Tanasawa distribution under the transient needle opening condition.

  18. Two-phase opening of Andaman Sea: a new seismotectonic insight

    NASA Astrophysics Data System (ADS)

    Khan, P. K.; Chakraborty, Partha Pratim

    2005-01-01

    High-resolution reconstruction of Benioff zone depth-dip angle trajectory for Burma-Java subduction margin between 2° and 17°N Lat. reveals two major episodes of plate geometry change expressed as abrupt deviation in subduction angle. Estimation of effective rate of subduction in different time slices (and then length of subducted slab) allowed drawing of isochrones in Ma interval through these trajectories for the time period 5-12 Ma. With these isochrones, the deformation events on the subducting Indian plate are constrained in time as of 4-5 and 11 Ma old. This well-constrained time connotation offered scope for the correlation of slab deformation events with the well-established two-phase opening history of the Andaman Sea. While the 11 Ma event recorded from southern part of the study area is correlated with early stretching and rifting phase, the 4-5 Ma event is interpreted as major forcing behind the spreading phase of the Andaman Sea. Systematic spatio-temporal evaluation of Indian plate obliquity on the Andaman Sea evolution shows its definite control on the early rifting phase, initiated towards south near northwest Sumatra. The much young spreading phase recorded towards north of 7° Lat. is possibly the result of late Miocene-Pliocene trench retreat and follow-up transcurrent movement (along Sagaing and Sumatran fault system) with NW-SE pull-apart extension. Nonconformity between plate shape and subduction margin geometry is interpreted as the causative force behind Mid-Miocene intraplate extension and tearing. Enhanced stretching in the overriding plate consequently caused active forearc subsidence, recorded all along this plate margin. Initial phase of the Andaman Sea opening presumably remains concealed in this early-middle Miocene forearc subsidence history. The late Miocene-Pliocene pull-apart opening and spreading was possibly initiated near the western part of the Mergui-Sumatra region and propagated northward in subsequent period. A temporary halt in rifting at this pull-apart stage and northeastward veering of the Andaman Sea Ridge (ASR) are related with uplifting of oceanic crust in post-middle Miocene time in form of Alcock and Sewell seamounts, lying symmetrically north and south of this spreading ridge.

  19. The distinction between juvenile and adult-onset primary open-angle glaucoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiggs, J.L.; Haines, J.L.; Damji, K.F.

    1996-01-01

    Because of the significant differences between the juvenile and adult forms of open-angle glaucoma, especially with regard to inheritance, prevalence, severity, and age of onset, we read with interest the recent publication by Morissette et al., describing a pedigree with a phenotype that overlaps the distinctive features of juvenile-onset open-angle glaucoma (JOAG) and adult-onset primary open-angle glaucoma (usually abbreviated as POAG or COAG). These authors conclude that a gene mapped to human chromosome 1q21-q31 (GLC1A) can be responsible for both juvenile and adult forms of open-angle glaucoma. The implications of such a result could be extremely important, in light ofmore » the high prevalence of the adult form of the disease. However, while the data presented in this report suggest that variable expressivity of the GLC1A gene may lead to a broader range of onset for this form of juvenile glaucoma, these data do not identify the GLC1A gene as an important cause of POAG. To prevent misleading interpretations of this and similar studies, we wish to clarify the distinction between the juvenile and adult forms of open-angle glaucoma. 8 refs.« less

  20. Factors associated with postoperative C5 palsy after expansive open-door laminoplasty: retrospective cohort study using multivariable analysis.

    PubMed

    Tsuji, Takashi; Matsumoto, Morio; Nakamura, Masaya; Ishii, Ken; Fujita, Nobuyuki; Chiba, Kazuhiro; Watanabe, Kota

    2017-09-01

    The aim of the present study was to investigate the factors associated with C5 palsy by focusing on radiological parameters using multivariable analysis. The authors retrospectively assessed 190 patients with cervical spondylotic myelopathy treated by open-door laminoplasty. Four radiographic parameters-the number of expanded lamina, C3-C7 angle, lamina open angle and space anterior to the spinal cord-were evaluated to clarify the factors associated with C5 palsy. Of the 190 patients, 11 developed C5 palsy, giving an overall incidence of 5.8%. Although the number of expanded lamina, lamina open angle and space anterior to the spinal cord were significantly larger in C5 palsy group than those in non-palsy group, a multiple logistic regression analysis revealed that only the space anterior to the spinal cord (odds ratio 2.60) was a significant independent factor associated with C5 palsy. A multiple linear regression analysis indicated that the lamina open angle was associated with the space anterior to the spinal cord and the analysis identified the following equation: space anterior to the spinal cord (mm) = 1.54 + 0.09 × lamina open angle (degree). A cut-off value of 53.5° for the lamina open angle predicted the development of C5 palsy with a sensitivity of 72.7% and a specificity of 83.2%. The larger postoperative space anterior to the spinal cord, which was associated with the lamina open angle, was positively correlated with the higher incidence of C5 palsy.

  1. Are we ready for genetic testing for primary open-angle glaucoma?

    PubMed

    Khawaja, Anthony P; Viswanathan, Ananth C

    2018-05-01

    Following a dramatic reduction in the cost of genotyping technology in recent years, there have been significant advances in the understanding of the genetic basis of glaucoma. Glaucoma patients represent around a quarter of all outpatient activity in the UK hospital eye service and are a huge burden for the National Health Service. A potential benefit of genetic testing is personalised glaucoma management, allowing direction of our limited healthcare resources to the glaucoma patients who most need it. Our review aims to summarise recent discoveries in the field of glaucoma genetics and to discuss their potential clinical utility. While genome-wide association studies have now identified over ten genes associated with primary open-angle glaucoma (POAG), individually, variants in these genes are not predictive of POAG in populations. There are data suggesting some of these POAG variants are associated with conversion from ocular hypertension to POAG and visual field progression among POAG patients. However, these studies have not been replicated yet and such genetic testing is not currently justified in clinical care. In contrast, genetic testing for inherited early-onset disease in relatives of POAG patients with a known genetic mutation is of clear benefit; this can support either regular review to commence early treatment when the disease develops, or discharge from ophthalmology services of relatives who do not carry the mutation. Genetic testing for POAG at a population level is not currently justified.

  2. Changes in Anterior Segment Morphology and Predictors of Angle Widening after Laser Iridotomy in South Indian Eyes.

    PubMed

    Zebardast, Nazlee; Kavitha, Srinivasan; Krishnamurthy, Palaniswamy; Friedman, David S; Nongpiur, Monisha E; Aung, Tin; Quigley, Harry A; Ramulu, Pradeep Y; Venkatesh, Rengaraj

    2016-12-01

    To compare anterior segment optical coherence tomography (ASOCT) angle morphology before and after laser peripheral iridotomy (LPI) in a cohort of South Indian subjects with primary angle-closure suspect (PACS) or primary angle-closure/primary angle-closure glaucoma (PAC/PACG) and to examine baseline parameters associated with angle widening. Prospective observational study. A total of 244 subjects aged ≥30 years with PACS or PAC/PACG in at least 1 eye. The ASOCT images and angle gonioscopic grades were analyzed for all subjects at baseline and 2 weeks after LPI. Multivariable linear and logistic regression models were used to determine predictors of angle widening (change in mean angle opening distance [AOD750]) and angle opening (all 4 quadrants with trabecular meshwork [TM] visible on gonioscopy after LPI). Change in ASOCT parameters with LPI and baseline predictors of angle widening. Laser peripheral iridotomy resulted in angle widening on ASOCT with significant increases in AOD750, angle recess area, and trabecular iris surface area (P < 0.05 for all). Gonioscopically, 44.7% of all subjects had open angles in all 4 quadrants after LPI, with a greater percentage of angles open in the PACS group compared with the PAC/PACG group (52.4% vs. 36.4%; P = 0.01). In multivariable regression analyses, greater postoperative angle widening as defined by change in AOD750 was associated with shorter baseline AOD750 and axial length, and greater baseline anterior chamber depth, iris curvature, and lens vault (P ≤ 0.002 for all). Gonioscopic angle opening after LPI was more common with wider baseline angle width (modified Shaffer grade) and lower cup-to-disc ratio (P < 0.001 for both). In a South Indian population with PACS or PAC/PACG, LPI results in significant anterior chamber angle widening seen on both ASOCT and gonioscopy, although some degree of persistent iridotrabecular contact was present in approximately half of PACS eyes and approximately two thirds of PAC/PACG eyes on gonioscopy. The greatest widening by ASOCT was observed in eyes with features most consistent with greater baseline pupillary block. Copyright © 2016 American Academy of Ophthalmology. All rights reserved.

  3. Undetected angle closure in patients with a diagnosis of open-angle glaucoma.

    PubMed

    Varma, Devesh K; Simpson, Sarah M; Rai, Amandeep S; Ahmed, Iqbal Ike K

    2017-08-01

    The aim of this study was to identify the proportion of patients referred to a tertiary glaucoma centre with a diagnosis of open-angle glaucoma (OAG) who were found to have angle closure glaucoma. Retrospective chart review. Consecutive new patients referred for glaucoma management to a tertiary centre between July 2010 and December 2011 were reviewed. Patients whose referrals for glaucoma assessment specified angle status as "open" were included. The data collected included glaucoma specialist's angle assessment, diagnosis, and glaucoma severity. The status of those with 180 degrees or more Shaffer angle grading of 0 was classified as "closed." From 1234 glaucoma referrals, 179 cases were specified to have a diagnosis of OAG or when angles were known to be open. Of these, 16 (8.9%) were found on examination by the glaucoma specialist to have angle closure. Pseudoexfoliation was present in 4 of 16 patients (25%) in the missed angle-closure glaucoma (ACG) group and 22 of 108 patients (13.5%) in the remaining OAG group. There was no difference found in demographic or ocular biometric parameters between those with confirmed OAG versus those with missed ACG. Almost 1 in 11 patients referred by ophthalmologists to a tertiary glaucoma centre with a diagnosis of OAG were in fact found to have angle closure. Given the different treatment approaches for ACG versus OAG, this study suggests a need to strengthen angle evaluations. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  4. Monte Carlo-based assessment of the trade-off between spatial resolution, field-of-view and scattered radiation in the variable resolution X-ray CT scanner.

    PubMed

    Arabi, Hossein; Kamali Asl, Ali Reza; Ay, Mohammad Reza; Zaidi, Habib

    2015-07-01

    The purpose of this work is to evaluate the impact of optimization of magnification on performance parameters of the variable resolution X-ray (VRX) CT scanner. A realistic model based on an actual VRX CT scanner was implemented in the GATE Monte Carlo simulation platform. To evaluate the influence of system magnification, spatial resolution, field-of-view (FOV) and scatter-to-primary ratio of the scanner were estimated for both fixed and optimum object magnification at each detector rotation angle. Comparison and inference between these performance parameters were performed angle by angle to determine appropriate object position at each opening half angle. Optimization of magnification resulted in a trade-off between spatial resolution and FOV of the scanner at opening half angles of 90°-12°, where the spatial resolution increased up to 50% and the scatter-to-primary ratio decreased from 4.8% to 3.8% at a detector angle of about 90° for the same FOV and X-ray energy spectrum. The disadvantage of magnification optimization at these angles is the significant reduction of the FOV (up to 50%). Moreover, magnification optimization was definitely beneficial for opening half angles below 12° improving the spatial resolution from 7.5 cy/mm to 20 cy/mm. Meanwhile, the FOV increased by more than 50% at these angles. It can be concluded that optimization of magnification is essential for opening half angles below 12°. For opening half angles between 90° and 12°, the VRX CT scanner magnification should be set according to the desired spatial resolution and FOV. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. Lack of Association of Mutations in Optineurin With Disease in Patients With Adult-onset Primary Open-angle Glaucoma

    PubMed Central

    Wiggs, Janey L.; Auguste, Josette; Allingham, R. Rand; Flor, Jason D.; Pericak-Vance, Margaret A.; Rogers, Kathryn; LaRocque, Karen R.; Graham, Felicia L.; Broomer, Bob; Del Bono, Elizabeth; Haines, Jonathan L.; Hauser, Michael

    2005-01-01

    Objective: To determine whether mutations in the optineurin gene contribute to susceptibility to adult-onset primary open-angle glaucoma. Methods: The optineurin gene was screened in 86 probands with adult-onset primary open-angle glaucoma and in 80 age-matched control subjects. Exons 4 and 5, containing the recurrent mutations identified in patients with normal-tension glaucoma, were sequenced in all individuals studied, while the remaining exons were screened for DNA sequence variants with denaturing high-performance liquid chromatography. Results: The recurrent mutation, Met98Lys, previously found to be associated with an increased risk of disease was found in 8 (9%) of 86 probands. We also found the Met98Lys mutation in 10% of individuals from a control population of similar age, sex, and ethnicity. Consistent segregation of the mutation with the disease was not demonstrated in any of the 8 families. No other DNA changes altering the amino acid structure of the protein were found. Conclusion: The mutations in the optineurin gene associated with normal-tension glaucoma are not associated with adult-onset primary open-angle glaucoma in this patient population. Clinical Relevance: Genetic abnormalities that render the optic nerve susceptible to degeneration are excellent candidates for genetic factors that could contribute to adult-onset primary open-angle glaucoma. Mutations in optineurin have been associated with normal-tension glaucoma, but are not associated with disease in patients with adult-onset primary open-angle glaucoma. This result may indicate that normal-tension glaucoma is not necessarily part of the phenotypic spectrum of adult open-angle glaucoma. PMID:12912697

  6. Progression of visual field in patients with primary open-angle glaucoma - ProgF study 1.

    PubMed

    Aptel, Florent; Aryal-Charles, Nishal; Giraud, Jean-Marie; El Chehab, Hussam; Delbarre, Maxime; Chiquet, Christophe; Romanet, Jean-Paul; Renard, Jean-Paul

    2015-12-01

    To evaluate the visual field rate of progression of patients with treated ocular hypertension (OHT) and primary open-angle glaucoma (POAG) in clinical practice, using the mean deviation (MD) and the visual field index (VFI). Non-interventional cohort study. From a large multicentre database representative of the French population, 441 eyes of 228 patients with treated OHT or POAG followed up at least 6 years with Humphrey 24.2 Sita-Standard visual field examination at least twice a year were identified. From initial data, eyes were classified in five groups: 121 with OHT, 188 with early glaucoma (MD greater than -6 dB), 45 with moderate glaucoma (MD -6 to -12 dB), 41 with advanced glaucoma (MD -12 to -18 dB) and 46 with severe glaucoma (MD less than -18 dB). Rate of progression during the follow-up period was calculated using the trend analysis of the Guided Progression Analysis software. The mean duration of follow-up was 8.4 ± 2.7 years and the mean number of visual field, 18.4 ± 3.5. In eyes with OHT, rate of progression was -0.09 dB/year (-0.17%VFI/year). In eyes with POAG, rate of progression was -0.32 dB/year (-0.83%VFI/year) in eyes with early glaucoma, -0.52 dB/year (-1.81%VFI/year) in moderate glaucoma, -0.54 dB/year (-2.35%VFI/year) in advanced glaucoma and -0.45 dB/year (-1.97%VFI/year) in severe glaucoma. In eyes with POAG, a significant progression (p < 0.05) was detected in 159 of 320 eyes (49.7%) with trend analysis and 117 of 320 eyes (36.6%, likely progression) or 183 of 320 eyes (57.2%, possible and likely progression) with event analysis. Primary open-angle glaucoma is a progressive disease in the majority of patients despite cautioned treatment and follow-up. The rate of progression varies greatly among subjects. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  7. EC95-43057-8

    NASA Image and Video Library

    1995-03-24

    Outlined with gold stripes are the hinged nose strakes, modifications made to NASA's F-18 HARV (High Alpha Research Vehicle) at the Dryden Flight Research Center, Edwards, California. Actuated Nose Strakes for Enhanced Rolling (ANSER) were installed to fly the third and final phase in the HARV flight test project. Normally folded flush, the units -- four feet long and six inches wide -- can be opened independently to interact with the nose vortices to produce large side forces for control. Early wind tunnel tests indicated that the strakes would be as effective in yaw control at high angles of attack as rudders are at lower angles. Testing involved evaluation of the strakes by themselves as well as combined with the aircraft's Thrust Vectoring System. The strakes were designed by NASA's Langley Research Center, then installed and flight tested at Dryden.

  8. Anterior Segment Imaging Predicts Incident Gonioscopic Angle Closure.

    PubMed

    Baskaran, Mani; Iyer, Jayant V; Narayanaswamy, Arun K; He, Yingke; Sakata, Lisandro M; Wu, Renyi; Liu, Dianna; Nongpiur, Monisha E; Friedman, David S; Aung, Tin

    2015-12-01

    To investigate the incidence of gonioscopic angle closure after 4 years in subjects with gonioscopically open angles but varying degrees of angle closure detected on anterior segment optical coherence tomography (AS OCT; Visante; Carl Zeiss Meditec, Dublin, CA) at baseline. Prospective, observational study. Three hundred forty-two subjects, mostly Chinese, 50 years of age or older, were recruited, of whom 65 were controls with open angles on gonioscopy and AS OCT at baseline, and 277 were cases with baseline open angles on gonioscopy but closed angles (1-4 quadrants) on AS OCT scans. All subjects underwent gonioscopy and AS OCT at baseline (horizontal and vertical single scans) and after 4 years. The examiner performing gonioscopy was masked to the baseline and AS OCT data. Angle closure in a quadrant was defined as nonvisibility of the posterior trabecular meshwork by gonioscopy and visible iridotrabecular contact beyond the scleral spur in AS OCT scans. Gonioscopic angle closure in 2 or 3 quadrants after 4 years. There were no statistically significant differences in age, ethnicity, or gender between cases and controls. None of the control subjects demonstrated gonioscopic angle closure after 4 years. Forty-eight of the 277 subjects (17.3%; 95% confidence interval [CI], 12.8-23; P < 0.0001) with at least 1 quadrant of angle closure on AS OCT at baseline demonstrated gonioscopic angle closure in 2 or more quadrants, whereas 28 subjects (10.1%; 95% CI, 6.7-14.6; P < 0.004) demonstrated gonioscopic angle closure in 3 or more quadrants after 4 years. Individuals with more quadrants of angle closure on baseline AS OCT scans had a greater likelihood of gonioscopic angle closure developing after 4 years (P < 0.0001, chi-square test for trend for both definitions of angle closure). Anterior segment OCT imaging at baseline predicts incident gonioscopic angle closure after 4 years among subjects who have gonioscopically open angles and iridotrabecular contact on AS OCT at baseline. Copyright © 2015 American Academy of Ophthalmology. All rights reserved.

  9. Open arthrolysis for elbow stiffness increases carrying angle but has no impact on functional recovery.

    PubMed

    Fan, Dapeng; Wang, Wei; Hildebrand, Kevin A; Fan, Cun-Yi

    2016-09-09

    With the exception of normal anatomic changes in the medial collateral ligament and radial head, other factors related to carrying angle changes have not been systematically studied. We reviewed patients who underwent open arthrolysis of the elbow, and evaluated if open arthrolysis could change carrying angle. We then identified factors associated with carrying angle changes. Fifty patients with a minimum of 24 months of follow-up after open arthrolysis were evaluated retrospectively. Preoperative and postoperative carrying angles were compared. The carrying angles of 36 elbows in 36 patients were unchanged after surgery (Group A), while the carrying angles of 14 elbows in 14 patients increased postoperatively (Group B). In Group A, mean postoperative extension and flexion were 7° (range 0-24°) and 125° (range 10-135°) respectively, while mean postoperative pronation and supination were 60° (range 50-80°) and 65° (range 30-85°), respectively. In Group B, mean postoperative extension and flexion were 25° (range 0-40°) and 128° (range 60-138°), while mean postoperative pronation and supination were 65° (range 45-85°) and 60° (range 45-75°), respectively. No significant difference in range of motion and Mayo Elbow Performance Score was observed between the two groups. During open arthrolysis, humeral trochlea debridement and techniques for improving forearm rotation could increase carrying angle. However, this had no impact on elbow functional recovery.

  10. Obstructive sleep apnoea syndrome in patients with primary open-angle glaucoma.

    PubMed

    Balbay, Ege G; Balbay, Oner; Annakkaya, Ali N; Suner, Kezban O; Yuksel, Harun; Tunç, Murat; Arbak, Peri

    2014-10-01

    To investigate the prevalence of obstructive sleep apnoea syndrome in patients with primary open-angle glaucoma. Case series. School of Medicine, Düzce University, Turkey. Twenty-one consecutive primary open-angle glaucoma patients (12 females and 9 males) who attended the out-patient clinic of the Department of Ophthalmology between July 2007 and February 2008 were included in this study. All patients underwent polysomnographic examination. The prevalence of obstructive sleep apnoea syndrome was 33.3% in patients with primary open-angle glaucoma; the severity of the condition was mild in 14.3% and moderate in 19.0% of the subjects. The age (P=0.047) and neck circumference (P=0.024) in patients with obstructive sleep apnoea syndrome were significantly greater than those without the syndrome. Triceps skinfold thickness in glaucomatous obstructive sleep apnoea syndrome patients reached near significance versus those without the syndrome (P=0.078). Snoring was observed in all glaucoma cases with obstructive sleep apnoea syndrome. The intra-ocular pressure of patients with primary open-angle glaucoma with obstructive sleep apnoea syndrome was significantly lower than those without obstructive sleep apnoea syndrome (P=0.006 and P=0.035 for the right and left eyes, respectively). There was no significant difference in the cup/disc ratio and visual acuity, except visual field defect, between primary open-angle glaucoma patients with and without obstructive sleep apnoea syndrome. Although it does not provide evidence for a cause-effect relationship, high prevalence of obstructive sleep apnoea syndrome in patients with primary open-angle glaucoma in this study suggests the need to explore the long-term results of coincidence, relationship, and cross-interaction of these two common disorders.

  11. Tank-Binding Kinase 1 (TBK1) Gene and Open-Angle Glaucomas (An American Ophthalmological Society Thesis)

    PubMed Central

    Fingert, John H.; Robin, Alan L.; Scheetz, Todd E.; Kwon, Young H.; Liebmann, Jeffrey M.; Ritch, Robert; Alward, Wallace L.M.

    2016-01-01

    Purpose To investigate the role of TANK-binding kinase 1 (TBK1) gene copy-number variations (ie, gene duplications and triplications) in the pathophysiology of various open-angle glaucomas. Methods In previous studies, we discovered that copy-number variations in the TBK1 gene are associated with normal-tension glaucoma. Here, we investigated the prevalence of copy-number variations in cohorts of patients with other open-angle glaucomas—juvenile-onset open-angle glaucoma (n=30), pigmentary glaucoma (n=209), exfoliation glaucoma (n=225), and steroid-induced glaucoma (n=79)—using a quantitative polymerase chain reaction assay. Results No TBK1 gene copy-number variations were detected in patients with juvenile-onset open-angle glaucoma, pigmentary glaucoma, or steroid-induced glaucoma. A TBK1 gene duplication was detected in one (0.44%) of the 225 exfoliation glaucoma patients. Conclusions TBK1 gene copy-number variations (gene duplications and triplications) have been previously associated with normal-tension glaucoma. An exploration of other open-angle glaucomas detected a TBK1 copy-number variation in a patient with exfoliation glaucoma, which is the first example of a TBK1 mutation in a glaucoma patient with a diagnosis other than normal-tension glaucoma. A broader phenotypic range may be associated with TBK1 copy-number variations, although mutations in this gene are most often detected in patients with normal-tension glaucoma. PMID:27881886

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chesler, Paul M.; Rajagopal, Krishna

    We calculate how the energy and the opening angle of jets in N = 4SYM theory evolve as they propagate through the strongly coupled plasma of that theory. We define the rate of energy loss dE jet/dx and the jet opening angle in a straightforward fashion directly in the gauge theory before calculating both holographically, in the dual gravitational description. In this way, we rederive the previously known result for dE jet/dx without the need to introduce a finite slab of plasma. We obtain a striking relationship between the initial opening angle of the jet, which is to say themore » opening angle that it would have had if it had found itself in vacuum instead of in plasma, and the thermalization distance of the jet. Via this relationship, we show that N = 4SYM jets with any initial energy that have the same initial opening angle and the same trajectory through the plasma experience the same fractional energy loss. We also provide an expansion that describes how the opening angle of the N = 4SYM jets increases slowly as they lose energy, over the fraction of their lifetime when their fractional energy loss is not yet large. In conclusion, we close by looking ahead toward potential qualitative lessons from our results for QCD jets produced in heavy collisions and propagating through quark-gluon plasma.« less

  13. Tank-Binding Kinase 1 (TBK1) Gene and Open-Angle Glaucomas (An American Ophthalmological Society Thesis).

    PubMed

    Fingert, John H; Robin, Alan L; Scheetz, Todd E; Kwon, Young H; Liebmann, Jeffrey M; Ritch, Robert; Alward, Wallace L M

    2016-08-01

    To investigate the role of TANK-binding kinase 1 ( TBK1 ) gene copy-number variations (ie, gene duplications and triplications) in the pathophysiology of various open-angle glaucomas. In previous studies, we discovered that copy-number variations in the TBK1 gene are associated with normal-tension glaucoma. Here, we investigated the prevalence of copy-number variations in cohorts of patients with other open-angle glaucomas-juvenile-onset open-angle glaucoma (n=30), pigmentary glaucoma (n=209), exfoliation glaucoma (n=225), and steroid-induced glaucoma (n=79)-using a quantitative polymerase chain reaction assay. No TBK1 gene copy-number variations were detected in patients with juvenile-onset open-angle glaucoma, pigmentary glaucoma, or steroid-induced glaucoma. A TBK1 gene duplication was detected in one (0.44%) of the 225 exfoliation glaucoma patients. TBK1 gene copy-number variations (gene duplications and triplications) have been previously associated with normal-tension glaucoma. An exploration of other open-angle glaucomas detected a TBK1 copy-number variation in a patient with exfoliation glaucoma, which is the first example of a TBK1 mutation in a glaucoma patient with a diagnosis other than normal-tension glaucoma. A broader phenotypic range may be associated with TBK1 copy-number variations, although mutations in this gene are most often detected in patients with normal-tension glaucoma.

  14. Auditory processing deficits in individuals with primary open-angle glaucoma.

    PubMed

    Rance, Gary; O'Hare, Fleur; O'Leary, Stephen; Starr, Arnold; Ly, Anna; Cheng, Belinda; Tomlin, Dani; Graydon, Kelley; Chisari, Donella; Trounce, Ian; Crowston, Jonathan

    2012-01-01

    The high energy demand of the auditory and visual pathways render these sensory systems prone to diseases that impair mitochondrial function. Primary open-angle glaucoma, a neurodegenerative disease of the optic nerve, has recently been associated with a spectrum of mitochondrial abnormalities. This study sought to investigate auditory processing in individuals with open-angle glaucoma. DESIGN/STUDY SAMPLE: Twenty-seven subjects with open-angle glaucoma underwent electrophysiologic (auditory brainstem response), auditory temporal processing (amplitude modulation detection), and speech perception (monosyllabic words in quiet and background noise) assessment in each ear. A cohort of age, gender and hearing level matched control subjects was also tested. While the majority of glaucoma subjects in this study demonstrated normal auditory function, there were a significant number (6/27 subjects, 22%) who showed abnormal auditory brainstem responses and impaired auditory perception in one or both ears. The finding that a significant proportion of subjects with open-angle glaucoma presented with auditory dysfunction provides evidence of systemic neuronal susceptibility. Affected individuals may suffer significant communication difficulties in everyday listening situations.

  15. Characteristic angles in the wetting of an angular region: deposit growth.

    PubMed

    Popov, Yuri O; Witten, Thomas A

    2003-09-01

    Solids dispersed in a drying drop migrate to the (pinned) contact line. This migration is caused by outward flows driven by the loss of the solvent due to evaporation and by geometrical constraint that the drop maintains an equilibrium surface shape with a fixed boundary. Here, in continuation of our earlier paper, we theoretically investigate the evaporation rate, the flow field, and the rate of growth of the deposit patterns in a drop over an angular sector on a plane substrate. Asymptotic power laws near the vertex (as distance to the vertex goes to zero) are obtained. A hydrodynamic model of fluid flow near the singularity of the vertex is developed and the velocity field is obtained. The rate of the deposit growth near the contact line is found in two time regimes. The deposited mass falls off as a weak power gamma of distance close to the vertex and as a stronger power beta of distance further from the vertex. The power gamma depends only slightly on the opening angle alpha and stays roughly between -1/3 and 0. The power beta varies from -1 to 0 as the opening angle increases from 0 degrees to 180 degrees. At a given distance from the vertex, the deposited mass grows faster and faster with time, with the greatest increase in the growth rate occurring at the early stages of the drying process.

  16. 46 CFR 172.065 - Damage stability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of sinkage, heel, and trim, must be below the lower edge of an opening through which progressive... sliding watertight door; or (vi) Side scuttle of the non-opening type. (2) Heel angle. The maximum angle of heel must not exceed 25 degrees, except that this angle may be increased to 30 degrees if no deck...

  17. 46 CFR 172.065 - Damage stability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of sinkage, heel, and trim, must be below the lower edge of an opening through which progressive... sliding watertight door; or (vi) Side scuttle of the non-opening type. (2) Heel angle. The maximum angle of heel must not exceed 25 degrees, except that this angle may be increased to 30 degrees if no deck...

  18. Proximal Tibia Medial Biplanar Retrotubercle Open Wedge Osteotomy for Varus Knees with Medial Gonarthrosis

    PubMed Central

    Türkmen, İsmail; Esenkaya, İrfan; Ünay, Koray; Türkmensoy, Fatih; Özkut, Afşar Timuçin

    2014-01-01

    Objectives: The purpose of this study is to evaluate the early results of proximal tibia medial biplanar retrotubercle open wedge osteotomy for varus gonarthrosis and compare the results with the literatüre. Methods: The results of proximal tibia medial biplanar retrotubercle open wedge osteotomy for 23 knees of 22 patients with medial gonarthrosis were evaluated clinically and radiologically. Results: Twenty of the patients were female and two were male. Mean age of the patients was 56.24; mean boy mass index was 31.95 and preoperative HSS (Hospital for Special Surgery) score was 68.7. Mean tibiofemoral axis was 186.39° and mean Insall-Salvatti index value was 1.04 preoperatively. Mean follow up period was 30.19 months. Mean HSS score was 86.48, femorotibial anatomic axis angle was 175° and Insall-Salvati index value 1.06 during the last follow-up. The improvement of the HSS score and the femorotibial anatomic axis angle was statistically significant. However, the change in Insall Salvati index values was statistically insignificant. Nonfatal pulmonary embolus in 1 patient, and deep vein thrombosis that occured one year after the procedure in 1 patient, rhabdomyolysis in 1 patient and loss of correction (relapse) in 1 patient were encountered as complications. Conclusion: Our results show that proximal tibia medial biplanar retrotubercle open wedge osteotomy improves the frontal and sagittal plane deformities without changing the patellar tendon length. Hence, possible patellofemoral problems are prevented and the clinical results are improved.

  19. Biomarkers in primary open angle glaucoma.

    PubMed

    Kokotas, Haris; Kroupis, Christos; Chiras, Dimitrios; Grigoriadou, Maria; Lamnissou, Klea; Petersen, Michael B; Kitsos, George

    2012-12-01

    Glaucoma, a leading cause of blindness worldwide, is currently defined as a disturbance of the structural or functional integrity of the optic nerve that causes characteristic atrophic changes in the optic nerve, which may lead to specific visual field defects over time. This disturbance usually can be arrested or diminished by adequate lowering of intraocular pressure (IOP). Glaucoma can be divided roughly into two main categories, ‘ open angle ’ and ‘ closed angle ’ glaucoma.Open angle, chronic glaucoma tends to progress at a slower rate and patients may not notice loss of vision until the disease has progressed significantly. Primary open angle glaucoma(POAG) is described distinctly as a multifactorial optic neuropathy that is chronic and progressive with a characteristic acquired loss of optic nerve fibers. Such loss develops in the presence of open anterior chamber angles, characteristic visual field abnormalities, and IOP that is too high for the healthy eye. It manifests by cupping and atrophy of the optic disc, in the absence of other known causes of glaucomatous disease. Several biological markers have been implicated with the disease. The purpose of this study was to summarize the current knowledge regarding the non-genetic molecular markers which have been predicted to have an association with POAG but have not yet been validated.

  20. What controls diffuse fractures in platform carbonates? Insights from Provence (France) and Apulia (Italy)

    NASA Astrophysics Data System (ADS)

    Lavenu, Arthur P. C.; Lamarche, Juliette

    2018-03-01

    Fractures are widespread in rocks and regional opening-mode arrays are commonly ascribed to major tectonic events. However, fractures occur in otherwise undeformed rocks. Some of these are early-developed features independent of tectonics and forming a background network at regional scale. To overcome this lack of understanding, two hydrocarbon reservoir analogues from platform carbonates have been targeted: the Provence (SE France), and the Apulian platform (SE Italy). In both areas, an early fracturing stage has been observed, made of high-angle-to-bedding opening-mode fractures, and bed-parallel stylolites. These features developed synchronously during the first burial stages and prior to major tectonic events. The fracture sets are not genetically related to the present-day layering. Contrarily, fractures developed in a brittle media where facies transitions were not sharp and did not act as mechanical discontinuities. Carbonate facies distribution and early diagenetic imprint constrained the mechanical stratigraphy when fractures occurred. In addition, we observed that fractures related to late tectonic inversion were partly inhibited. Indeed, rock mechanical properties change through time. Characterizing the temporal evolution of carbonate rocks has revealed that diagenesis and sedimentary facies are the prime actors for brittleness and mechanical layering in carbonates.

  1. The Influence of Structure Heights and Opening Angles of Micro- and Nanocones on the Macroscopic Surface Wetting Properties

    NASA Astrophysics Data System (ADS)

    Schneider, Ling; Laustsen, Milan; Mandsberg, Nikolaj; Taboryski, Rafael

    2016-02-01

    We discuss the influence of surface structure, namely the height and opening angles of nano- and microcones on the surface wettability. We show experimental evidence that the opening angle of the cones is the critical parameter on sample superhydrophobicity, namely static contact angles and roll-off angles. The textured surfaces are fabricated on silicon wafers by using a simple one-step method of reactive ion etching at different processing time and gas flow rates. By using hydrophobic coating or hydrophilic surface treatment, we are able to switch the surface wettability from superhydrophilic to superhydrophobic without altering surface structures. In addition, we show examples of polymer replicas (polypropylene and poly(methyl methacrylate) with different wettability, fabricated by injection moulding using templates of the silicon cone-structures.

  2. Effect of the meniscus contact angle during early regimes of spontaneous imbibition in nanochannels.

    PubMed

    Karna, Nabin Kumar; Oyarzua, Elton; Walther, Jens H; Zambrano, Harvey A

    2016-11-30

    Nanoscale capillarity has been extensively investigated; nevertheless, many fundamental questions remain open. In spontaneous imbibition, the classical Lucas-Washburn equation predicts a singularity as the fluid enters the channel consisting of an anomalous infinite velocity of the capillary meniscus. Bosanquet's equation overcomes this problem by taking into account fluid inertia predicting an initial imbibition regime with constant velocity. Nevertheless, the initial constant velocity as predicted by Bosanquet's equation is much greater than those observed experimentally. In the present study, large scale atomistic simulations are conducted to investigate capillary imbibition of water in slit silica nanochannels with heights between 4 and 18 nm. We find that the meniscus contact angle remains constant during the inertial regime and its value depends on the height of the channel. We also find that the meniscus velocity computed at the channel entrance is related to the particular value of the meniscus contact angle. Moreover, during the subsequent visco-inertial regime, as the influence of viscosity increases, the meniscus contact angle is found to be time dependent for all the channels under study. Furthermore, we propose an expression for the time evolution of the dynamic contact angle in nanochannels which, when incorporated into Bosanquet's equation, satisfactorily explains the initial capillary rise.

  3. Manchester iStent study: early results from a prospective UK case series.

    PubMed

    Patel, Ilesh; de Klerk, Timothy A; Au, Leon

    2013-01-01

    To evaluate the 6-month efficacy and safety of the iStent microtrabecular bypass stent in patients with open-angle glaucoma. A prospective, uncontrolled, interventional case series. Forty-four eyes with open-angle glaucoma were reported. All subjects underwent ab interno implantation of a single iStent together with (n = 40) or without (n = 4) cataract surgery. Patients were assessed at postoperative week 1, months 1 and 3, and quarterly, thereafter. Data collected included visual acuity, intraocular pressure measurement using Goldmann tonometry, number of glaucoma medications, and number and type of complications. The mean age of the sample was 76.8 years. The mean duration since glaucoma diagnosis was 5.3 years (standard deviation 2.9 years). The mean visual acuity was 0.53 logMAR at baseline that improved to 0.23 at 6 months postoperatively. The mean baseline intraocular pressure was 21.1 mmHg, and this decreased significantly to 16.7 mmHg at 6 months (P < 0.01). The mean number of drops prescribed preoperatively was 2.3, which decreased to 0.6 at 6 months (P < 0.01). Sixty-six per cent of patients were drop-free at 6 months. One patient developed an hyphaema following surgery; no other adverse events were recorded. The iStent proved to be a safe and effective treatment for patients with open-angle glaucoma over our 6-month follow up period. Insertion resulted in a significant decrease in intraocular pressure as well as the number of topical antiglaucoma medications required for adequate intraocular pressure control. © 2013 The Authors. Clinical and Experimental Ophthalmology © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  4. Measuring charged particle multiplicity with early ATLAS public data

    NASA Astrophysics Data System (ADS)

    Üstün, G.; Barut, E.; Bektaş, E.; Özcan, V. E.

    2017-07-01

    We study 100 images of early LHC collisions that were recorded by the ATLAS experiment and made public for outreach purposes, and extract the charged particle multiplicity as a function of momentum for proton-proton collisions at a centre-of-mass energy of 7 TeV. As these collisions have already been pre-processed by the ATLAS Collaboration, the particle tracks are visible, but are available to the public only in the form of low-resolution bitmaps. We describe two separate image processing methods, one based on the industry-standard OpenCV library and C++, another based on self-developed algorithms in Python. We present our analysis of the transverse momentum and azimuthal angle distributions of the particles, in agreement with the literature.

  5. Effect of aperture geometry on heat transfer in tilted partially open cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elsayed, M.M.; Chakroun, W.

    1999-11-01

    Heat transfer in cavities is receiving increasing attention because of the various applications in engineering; e.g., passive solar heating, energy conservation in buildings, solar concentrating receivers, and electronic equipment. Here, convection from a square, tilted partially open cavity was investigated experimentally. The experiment was carried out to study the effect of the aperture geometry on the heat transfer between the cavity and the surrounding air. Four different geometrical arrangements for the opening were investigated: (1) high wall slit, (2) low wall slit, (3) centered wall slit, and (4) uniform wall slots. Each opening arrangement was studied at opening ratios (i.e.,more » ratio of opening height to cavity height) of 0.25, 0.5, and 0.75. The average heat transfer coefficient between the cavity and the surrounding air was estimated for each geometrical arrangement for tilt angles ranging from {minus}90 deg to +90 deg with increments of 15 deg and at a constant heat flux Grashof number of 5.5 x 10{sup 8}. The results showed that for tilt angles between 90 and 75 deg, the heat transfer coefficient has a small value that is independent of the geometrical arrangement of the opening. The value of the heat transfer coefficient increases sharply with decreasing tilt angle until an angle value of zero degrees is reached. The increase in the heat transfer coefficient continues in the negative range of tilt angle but not in the same rate as in the positive range of the tilt angle. The uniform slot arrangement gave in general higher heat transfer coefficient than the other three arrangements of the opening. Large differences in the heat transfer coefficient were observed between the high and the low wall slits where the high wall slit is found to transfer more heat to the surroundings than the low wall slit. Correlations were developed to predict the average Nusselt number of the cavity in terms of the opening ratio and the cavity tilt angle for cavities with high wall slit, low wall slit, centered wall slit, and the uniform wall slots.« less

  6. Pupillary Responses to Full-Field Chromatic Stimuli Are Reduced in Patients with Early-Stage Primary Open-Angle Glaucoma.

    PubMed

    Najjar, Raymond P; Sharma, Sourabh; Atalay, Eray; Rukmini, Annadata V; Sun, Christopher; Lock, Jing Zhan; Baskaran, Mani; Perera, Shamira A; Husain, Rahat; Lamoureux, Ecosse; Gooley, Joshua J; Aung, Tin; Milea, Dan

    2018-03-21

    To evaluate the ability of chromatic pupillometry to reveal abnormal pupillary responses to light in patients with early-stage primary open-angle glaucoma (POAG) and to test whether the degree of pupillometric impairment correlates with structural hallmarks of optic nerve damage in the disease. Cross-sectional study. Forty-six patients with early-stage POAG (63.4±8.3 years, 63% male, 87% ethnic-Chinese) and 90 age-matched healthy controls (61.4±8.6 years, 34% male, 89% ethnic-Chinese). Patients with POAG had a visual field mean deviation (VFMD) of -6 decibels or better on automated perimetry. Each participant underwent a monocular 2-minute exposure to blue light (462 nm) followed by another 2-minute exposure to red light (638 nm) using a modified Ganzfeld dome equipped with a light-emitting diode lighting system. The light stimuli intensity was increased logarithmically to evaluate the combined extrinsic and intrinsic response of intrinsically photosensitive retinal ganglion cells (ipRGCs). Light-induced changes in horizontal pupil diameter were assessed monocularly using infrared pupillography. Baseline-adjusted, light-induced pupillary constriction amplitudes were calculated, and individual irradiance-response curves were constructed for each stimulus. Pupillary constriction amplitudes were compared between groups and across light intensities using a linear mixed model analysis. The linear relationship between pupillometric parameters and different structural and functional features of glaucoma was assessed using Pearson's correlation analysis. Light-induced pupillary constriction was reduced in patients with early-stage POAG compared with controls at moderate to high irradiances (≥11 Log photons/cm 2 /s) of blue (P = 0.003) and red (P < 0.001) light. Maximal pupillary constriction amplitude was correlated with retinal nerve fiber layer thickness (RNFL) thickness (blue: r = 0.51, P < 0.001; red: r = 0.45, P = 0.002) in patients with POAG but not in controls. Conversely, pupillometric parameters were not correlated with visual field scores in patients with early-stage POAG. Patients with early-stage POAG exhibit reduced pupillary responses to moderate and high irradiances of blue and red lights. This wavelength-independent functional alteration correlates with structural thinning of the RNFL and could be the consequence of dysfunction or loss of melanopsin expressing ipRGCs in the early stages of the disease. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  7. [Magnetotherapy designed to affect cervical sympathetic ganglia for the treatment of patients with primary open-angle glaucoma].

    PubMed

    Veselova, E V; Kamenskikh, T G; Raĭgorodkiĭ, Iu M; Kolbenev, I O; Myshkina, E S

    2010-01-01

    The traveling magnetic field was used to treat primary open-angle glaucoma. The field was applied to the projection of cervical sympathetic ganglia of the patients. Hemodynamic parameters of posterior short ciliary arteries and central retinal artery were analysed along with visual evoked potentials, visual field limits, and visual acuity. It was shown that magnetotherapy with the use of an AMO-ATOS apparatus produces better clinical results in patients with stage I and II primary open-angle glaucoma compared with medicamentous therapy (intake of trental tablets).

  8. 46 CFR 174.207 - Damaged stability criteria.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... sinkage, heel, and trim, must be below the lower edge of an opening through which progressive flooding may... of this subpart; or (v) Side scuttle of the non-opening type. (2) Angle of heel. The angle of heel...

  9. Middle Jurassic - Early Cretaceous rifting on the Chortis Block in Honduras: Implications for proto-Caribbean opening (Invited)

    NASA Astrophysics Data System (ADS)

    Rogers, R. D.; Emmet, P. A.

    2009-12-01

    Regional mapping integrated with facies analysis, age constraints and airborne geophysical data reveal WNW and NE trends of Middle Jurassic to Early Cretaceous basins which intersect in southeast Honduras that we interpret as the result of rifting associated with the breakup of the Americas and opening of the proto-Caribbean seaway. The WNW-trending rift is 250 km long by 90 km wide and defined by a basal 200 to 800 m thick sequence of Middle to Late Jurassic fluvial channel and overbank deposits overlain by transgressive clastic shelf strata. At least three sub-basins are apparent. Flanking the WNW trending rift basins are fault bounded exposures of the pre-Jurassic continental basement of the Chortis block which is the source of the conglomeratic channel facies that delineate the axes of the rifts. Cretaceous terrigenous strata mantle the exposed basement-cored rift flanks. Lower Cretaceous clastic strata and shallow marine limestone strata are dominant along this trend indicating that post-rift related subsidence continued through the Early Cretaceous. The rifts coincide with a regional high in the total magnetic intensity data. We interpret these trends to reflect NNE-WSW extension active from the Middle Jurassic through Early Cretaceous. These rifts were inverted during Late Cretaceous shortening oriented normal to the rift axes. To the east and at a 120 degree angle to the WNW trending rift is the 300 km long NE trending Guayape fault system that forms the western shoulder of the Late Jurassic Agua Fria rift basin filled by > 2 km thickness of clastic marine shelf and slope strata. This NE trending basin coincides with the eastern extent of the surface exposure of continental basement rocks and a northeast-trending fabric of the Jurassic (?) metasedimentary basement rocks. We have previously interpreted the eastern basin to be the Jurassic rifted margin of the Chortis block with the Guayape originating as a normal fault system. These two rifts basin intersect at near 120 degree angle in southeastern Honduras. We suggest that the intersection of these two trends represents part of a R-R-R triple junction during the breakup of the Americas. The WNW trending rift produced the WNW trending fabric of the central Chortis block and failed in the Early Cretaceous while the NE trending rift continued opening to form the south-facing passive margin of the northern proto-Caribbean basin.

  10. High prevalence of narrow angles among Chinese-American glaucoma and glaucoma suspect patients.

    PubMed

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data were collected for sex, age, race (self-declared), refraction (spherical equivalent), intraocular pressure, gonioscopy, and vertical cup-to-disk ratio. Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade < or = 2 in 3 or more quadrants). Those with narrow angles were significantly older (P=0.004) than their open angle counterparts, but the 2 groups did not differ in terms of sex, refraction, intraocular pressure, or cup-to-disk ratio (all, P > or = 0.071). In a multivariate model including age, sex, and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of sex or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed.

  11. Assessment of morphological and anatomical characteristics of mental foramen using cone beam computed tomography.

    PubMed

    Goyushov, Samir; Tözüm, Melek Didem; Tözüm, Tolga Fikret

    2018-05-25

    To determine the shape, position, vertical height, surrounding bone characteristics, and opening angle of mental foramen (MF) using dental cone beam computed tomography (CBCT). A retrospective study was performed on 663 patients. CBCT records analyzed for the shape, position, and surrounding bone measurements of the MF using Simplant 3D software (Hasselt, Belgium). Opening angle of MF was also assessed. Kruskal-Wallis and Mann-Whitney U tests were employed to test significant differences between parameters, genders and ages. All mental foramina were visualized. Regarding location, 49.2% of the MFs were located between first and second premolars, 7.7 distal and 39.7% coincident to the apex of the mandibular second premolar. The mean MF opening angle was 45.4° on the right side, and 45.9° on the left. There were no statistically differences between gender groups with regard to the opening angle degrees. This study may provide useful information about variations in the position, shape and size, angle of mental foramen, which may help the practitioners to perform safer mental nerve blocks and surgical procedures.

  12. Agreement between Gonioscopic Examination and Swept Source Fourier Domain Anterior Segment Optical Coherence Tomography Imaging

    PubMed Central

    Nguyen, Donna; Minnal, Vandana R.

    2016-01-01

    Purpose. To evaluate interobserver, intervisit, and interinstrument agreements for gonioscopy and Fourier domain anterior segment optical coherence tomography (FD ASOCT) for classifying open and narrow angle eyes. Methods. Eighty-six eyes with open or narrow anterior chamber angles were included. The superior angle was classified open or narrow by 2 of 5 glaucoma specialists using gonioscopy and imaged by FD ASOCT in the dark. The superior angle of each FD ASOCT image was graded as open or narrow by 2 masked readers. The same procedures were repeated within 6 months. Kappas for interobserver and intervisit agreements for each instrument and interinstrument agreements were calculated. Results. The mean age was 50.9 (±18.4) years. Interobserver agreements were moderate to good for both gonioscopy (0.57 and 0.69) and FD ASOCT (0.58 and 0.75). Intervisit agreements were moderate to excellent for both gonioscopy (0.53 to 0.86) and FD ASOCT (0.57 and 0.85). Interinstrument agreements were fair to good (0.34 to 0.63), with FD ASOCT classifying more angles as narrow than gonioscopy. Conclusions. Both gonioscopy and FD ASOCT examiners were internally consistent with similar interobserver and intervisit agreements for angle classification. Agreement between instruments was fair to good, with FD ASOCT classifying more angles as narrow than gonioscopy. PMID:27990300

  13. Glaucoma anterior chamber morphometry based on optical Scheimpflug images.

    PubMed

    Alonso, Ruiz Simonato; Ambrósio Junior, Renato; Paranhos Junior, Augusto; Sakata, Lisandro Massanori; Ventura, Marcelo Palis

    2010-01-01

    To compare the performance of gonioscopy and noncontact morphometry with anterior chamber tomography (High Resolution Pentacam - HR) using optical Scheimpflug images in the evaluation of the anterior chamber angle (ACA). Transversal study. 112 eyes from 74 subjects evaluated at the Glaucoma Department, Fluminense Federal University, underwent gonioscopy and Pentacam HR. Using gonioscopy, the ACA was graded using the Shaffer Classification (SC) by a single experienced examiner masked to the Pentacam HR findings. Narrow angle was determined in eyes in which the posterior trabecular meshwork could not be seen in two or more quadrants on non-indentation gonioscopy (SC Grade 2 or less). Pentacam HR images of the nasal and temporal quadrants were evaluated by custom software to automatically obtain anterior chamber measurements, such as: anterior chamber angle (ACA), anterior chamber volume (ACV) and anterior chamber depth (ACD). Based on gonioscopy results, 74 (60.07%) eyes of patients classified as open-angle (SC 3 and 4) and 38 (33.93%) eyes of patients classified as narrow-angle (SC 1 and 2). Noncontact morphometry with Scheimpflug images revealed a mean ACA of 39.20 ± 5.31 degrees for open-angle and 21.18 ± 7.98 degrees for narrow-angle. The open-angle group showed significant greater ACV and ACD values when compared to narrow-angle group (ACV of 193 ± 36 mm³ vs. 90 ± 25 mm³, respectively, p<0.001; and ACD of 3,09 ± 0,42 mm vs. 1,55 ± 0,64 mm, respectively, p<0.0001.). In screening eyes with open-angle and narrow-angle with the Pentacam ACA of 20º (SC Grade 2) using the ROC curves, the analysis showed 52.6% of sensitivity and 100% of specificity. The Pentacam showed ability in detecting eyes at risk for angle closure analyzing ACV and ACD.

  14. Diagnostic Capability of Peripapillary Retinal Volume Measurements in Glaucoma.

    PubMed

    Simavli, Huseyin; Poon, Linda Yi-Chieh; Que, Christian J; Liu, Yingna; Akduman, Mustafa; Tsikata, Edem; de Boer, Johannes F; Chen, Teresa C

    2017-06-01

    To determine the diagnostic capability of spectral domain optical coherence tomography peripapillary retinal volume (RV) measurements. A total of 156 patients, 89 primary open-angle glaucoma and 67 normal subjects, were recruited. Spectral domain optical coherence tomography peripapillary RV was calculated for 4 quadrants using 3 annuli of varying scan circle diameters: outer circumpapillary annuli of circular grids 1, 2, and 3 (OCA1, OCA2, OCA3). Area under the receiver operating characteristic curves and pairwise comparisons of receiver operating characteristic (ROC) curves were performed to determine which quadrants were best for diagnosing primary open-angle glaucoma. The pairwise comparisons of the best ROC curves for RV and retinal nerve fiber layer (RNFL) were performed. The artifact rates were analyzed. Pairwise comparisons showed that the smaller annuli OCA1 and OCA2 had better diagnostic performance than the largest annulus OCA3 (P<0.05 for all quadrants). OCA1 and OCA2 had similar diagnostic performance, except for the inferior quadrant which was better for OCA1 (P=0.0033). The pairwise comparisons of the best ROC curves for RV and RNFL were not statistically significant. RV measurements had lower rates of artifacts at 7.4% while RNFL measurements had higher rates at 42.9%. Peripapillary RV measurements have excellent ability for diagnosing not only glaucoma patients but also a subset of early glaucoma patients. The inferior quadrant of peripapillary annulus OCA1 demonstrated the best diagnostic capability for both glaucoma and early glaucoma. The diagnostic ability of RV is comparable with that of RNFL parameters in glaucoma but with lower artifact rates.

  15. Do non-communicable diseases such as hypertension and diabetes associate with primary open-angle glaucoma? Insights from a case-control study in Nepal.

    PubMed

    Shakya-Vaidya, Suraj; Aryal, Umesh Raj; Upadhyay, Madan; Krettek, Alexandra

    2013-11-04

    Non-communicable diseases (NCDs) such as hypertension and diabetes are rapidly emerging public health problems worldwide, and they associate with primary open-angle glaucoma (POAG). POAG is the most common cause of irreversible blindness. The most effective ways to prevent glaucoma blindness involve identifying high-risk populations and conducting routine screening for early case detection. This study investigated whether POAG associates with hypertension and diabetes in a Nepalese population. To explore the history of systemic illness, our hospital-based case-control study used non-random consecutive sampling in the general eye clinics in three hospitals across Nepal to enroll patients newly diagnosed with POAG and controls without POAG. The study protocol included history taking, ocular examination, and interviews with 173 POAG cases and 510 controls. Data analysis comprised descriptive and inferential statistics. Descriptive statistics computed the percentage, mean, and standard deviation (SD); inferential statistics used McNemar's test to measure associations between diseases. POAG affected males more frequently than females. The odds of members of the Gurung ethnic group having POAG were 2.05 times higher than for other ethnic groups. Hypertension and diabetes were strongly associated with POAG. The overall odds of POAG increased 2.72-fold among hypertensive and 3.50-fold among diabetic patients. POAG associates significantly with hypertension and diabetes in Nepal. Thus, periodic glaucoma screening for hypertension and diabetes patients in addition to opportunistic screening at eye clinics may aid in detecting more POAG cases at an early stage and hence in reducing avoidable blindness.

  16. Peripapillary schisis in open-angle glaucoma.

    PubMed

    Dhingra, N; Manoharan, R; Gill, S; Nagar, M

    2017-03-01

    PurposeTo report clinical features, topographic findings and outcome of 10 eyes with peripapillary schisis in open-angle glaucoma.Patients and methodsA retrospective review of patients with open-angle glaucoma who were noted to have peripapillary schisis on optical coherence tomography (OCT) were included. Serial peripapillary and macula infrared and OCT images, visual acuity, visual fields, and schisis appearance were reviewed.ResultsTen eyes of nine patients with open-angle glaucoma were detected to have the presence of peripapillary schisis. Nerve fibre layer schisis was detected in all eyes and one eye had an associated macular schisis. None of the eyes had an acquired pit of the optic nerve or pathological myopia. The mean intraocular pressures at detection was 18.3±4.3 mm Hg and the schisis resolved in four eyes after a mean follow-up of 21.2±8.8 months. Visual field worsening was noted in 4 of the 10 eyes and the resolution of schisis resulted in significant reduction in the retinal nerve fibre layer (RNFL) thickness.ConclusionsPeripapillary schisis detected during the normal course of open-angle glaucoma can resolve spontaneously and rarely involves the macula. Its resolution leads to reduction in RNFL thickness; therefore, caution is advised while interpreting serial scans.

  17. Assessment of narrow angles by gonioscopy, Van Herick method and anterior segment optical coherence tomography.

    PubMed

    Park, Seong Bae; Sung, Kyung Rim; Kang, Sung Yung; Jo, Jung Woo; Lee, Kyoung Sub; Kook, Michael S

    2011-07-01

    To evaluate anterior chamber (AC) angles using gonioscopy, Van Herick technique and anterior segment optical coherence tomography (AS-OCT). One hundred forty-eight consecutive subjects were enrolled. The agreement between any two of three diagnostic methods, gonioscopy, AS-OCT and Van Herick, was calculated in narrow-angle patients. The area under receiver-operating characteristic curves (AUC) for discriminating between narrow and open angles determined by gonioscopy was calculated in all participants for AS-OCT parameter angle opening distance (AOD), angle recess area, trabecular iris surface area and anterior chamber depth (ACD). As a subgroup analysis, capability of AS-OCT parameters for detecting angle closure defined by AS-OCT was assessed in narrow-angle patients. The agreement between the Van Herick method and gonioscopy in detecting angle closure was excellent in narrow angles (κ = 0.80, temporal; κ = 0.82, nasal). However, agreement between gonioscopy and AS-OCT and between the Van Herick method and AS-OCT was poor (κ = 0.11-0.16). Discrimination capability of AS-OCT parameters between open and narrow angles determined by gonioscopy was excellent for all AS-OCT parameters (AUC, temporal: AOD500 = 0.96, nasal: AOD500 = 0.99). The AUCs for detecting angle closure defined by AS-OCT image in narrow angle subjects was good for all AS-OCT parameters (AUC, 0.80-0.94) except for ACD (temporal: ACD = 0.70, nasal: ACD = 0.63). Assessment of narrow angles by gonioscopy and the Van Herick technique showed good agreement, but both measurements revealed poor agreement with AS-OCT. The angle closure detection capability of AS-OCT parameters was excellent; however, it was slightly lower in ACD.

  18. Detection of Glaucoma Using Image Processing Techniques: A Critique.

    PubMed

    Kumar, B Naveen; Chauhan, R P; Dahiya, Nidhi

    2018-01-01

    The primary objective of this article is to present a summary of different types of image processing methods employed for the detection of glaucoma, a serious eye disease. Glaucoma affects the optic nerve in which retinal ganglion cells become dead, and this leads to loss of vision. The principal cause is the increase in intraocular pressure, which occurs in open-angle and angle-closure glaucoma, the two major types affecting the optic nerve. In the early stages of glaucoma, no perceptible symptoms appear. As the disease progresses, vision starts to become hazy, leading to blindness. Therefore, early detection of glaucoma is needed for prevention. Manual analysis of ophthalmic images is fairly time-consuming and accuracy depends on the expertise of the professionals. Automatic analysis of retinal images is an important tool. Automation aids in the detection, diagnosis, and prevention of risks associated with the disease. Fundus images obtained from a fundus camera have been used for the analysis. Requisite pre-processing techniques have been applied to the image and, depending upon the technique, various classifiers have been used to detect glaucoma. The techniques mentioned in the present review have certain advantages and disadvantages. Based on this study, one can determine which technique provides an optimum result.

  19. High Prevalence of Narrow Angles among Chinese-American Glaucoma and Glaucoma Suspect Patients

    PubMed Central

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    Purpose To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Patients and Methods Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data was collected for gender, age, race (self-declared), refraction (spherical equivalent), intraocular pressure (IOP), gonioscopy and vertical cup-to-disk ratio (CDR). Results Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade ≤2 in three or more quadrants). Those with narrow angles were significantly older (P=0.004) than their open angle counterparts, but the two groups did not differ in terms of gender, refraction, IOP or CDR (all, P≥0.071). In a multivariate model including age, gender and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). Conclusions A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of gender or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed. PMID:19826385

  20. Comparison of a technique using a new percutaneous osteosynthesis device with conventional open surgery for displaced patella fractures in a randomized controlled trial.

    PubMed

    Luna-Pizarro, Daniel; Amato, Dante; Arellano, Francisco; Hernández, Armando; López-Rojas, Pablo

    2006-09-01

    To compare the percutaneous patellar osteosynthesis system (PPOS) technique with open surgery for patella fractures. Randomized controlled trial. Referral orthopedic and trauma center. Fifty-three patients with displaced patellar fractures. Stabilization and fixation of patellar fractures with PPOS or open surgery. Knee-flexion and -extension angles, pain, surgical time, and assessment of knee function based on the Knee Society Clinical Rating Scale (KSCRS). Comparison of PPOS and open-surgery groups at 4 weeks showed the following: pain, 3.7 +/- 1.6 versus 6.2 +/- 1.4 arbitrary units, P < 0.001; flexion angle, 46 +/- 20.7 versus 12.7 +/- 6.0 degrees, P < 0.001; extension angle, -2.5 versus -3.8 degrees, P < 0.001. At 8 weeks, the following was demonstrated: pain, 1.3 +/- 1.6 versus 4.1 +/- 2.1 arbitrary units, P < 0.001; flexion angle, 87 +/- 17.3 versus 34 +/- 26 degrees, P < 0.001; extension angle, 0 versus -3 degrees, P < 0.001. Surgical time was 35.3 +/- 7.8 versus 66.2 +/- 14.1 minutes, P < 0.001. KSCRS assessment was 84 +/- 4 versus 70 +/- 8, P < 0.001 at 8 weeks; 85 +/- 2 versus 73 +/- 8, P < 0.001 at 12 months; and 85 +/- 1 versus 82 +/- 7, P = 0.246 at 24 months. Frequency of total complications (infections, fragment displacement, and wire-related pain) was significantly lower in the PPOS than in the open-surgery group (P < 0.02). PPOS for patella fractures was associated with shorter surgical time, less pain, better mobility angles, higher functional score up to 2 years, and a lower incidence of complications than open surgery.

  1. Regional distribution of circumferential residual strains in the human aorta according to age and gender.

    PubMed

    Sokolis, Dimitrios P; Savva, Giannis D; Papadodima, Stavroula A; Kourkoulis, Stavros K

    2017-03-01

    The biomechanical response of the human aorta varies with axial location, but little is known about the respective variation of residual strains. Such data are available for common lab animals, but in the traditional opening angle measurement the aorta is considered as an ideal cylinder and average residual strains are measured, so that the spatial variations of local residual strains are not determined. The present study provides opening angle and residual strain data throughout the course and around the circumference of the aorta harvested during autopsy. Opening angle showed notable topographical variation; the highest value was at the top of aortic arch, declining abruptly toward the ascending aorta and to a near-constant value in the descending aorta, and rising in the abdominal aorta. The variation of curvature and of external but not internal residual stretch resembled that of opening angle. Extensive residual stress and wall thickness differences were evidenced among quadrants, with the more pre-stressed being also the thicker quadrants. Gender had overall minor effects, but aging led to increased parameters, occurring earlier in the distal aorta but at later stages becoming predominant proximally. Differences in caliber were pronounced in older subjects, unlike those in opening angle, residual stretches, and thickness that were striking in middle-aged subjects. By contrast, curvature decreased with aging in relation to the smaller percentwise opening angle differences. Detailed knowledge of the zero-stress/no-load geometry of the human aortic wall is critical for an in-depth understanding of aortic physiology, while providing the basis for comparison with disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Gonioscopy-assisted Transluminal Trabeculotomy: An Ab Interno Circumferential Trabeculotomy: 24 Months Follow-up.

    PubMed

    Grover, Davinder S; Smith, Oluwatosin; Fellman, Ronald L; Godfrey, David G; Gupta, Aditi; Montes de Oca, Ildamaris; Feuer, William J

    2018-05-01

    The purpose of this study was to provide 24-month follow-up on surgical success and safety of an ab interno circumferential 360-degree trabeculotomy. Chart review of patients who underwent a gonioscopy-assisted transluminal trabeculotomy (GATT) procedure was performed by 4 of the authors (D.S.G., O.S., R.L.F., and D.G.G.). The surgery was performed in adults with various types of open-angle glaucoma with preoperative intraocular pressures (IOPs) of ≥18 mm Hg. In total, 198 patients aged 24 to 89 years underwent the GATT procedure with at least 18 months follow-up. Patients with primary open-angle glaucoma had an average IOP decrease of 9.2 mm Hg at 24 months with an average decrease of 1.43 glaucoma medications. The mean percentage of IOP decrease in these primary open-angle glaucoma groups at 24 months was 37.3%. In secondary open-angle glaucoma, at 24 months there was an average decrease in IOP of 14.1 mm Hg on an average of 2.0 fewer medications. The mean percentage of IOP decrease in the secondary open-angle glaucoma groups at 24 months was 49.8%. The cumulative proportion of failure at 24 months ranged from 0.18 to 0.48, depending on the group. In all 6 study groups, at all 5 postoperative time points (3, 6, 12, 18, and 24 mo) the mean IOP and reduction in glaucoma medications was significantly reduced from baseline (P<0.001) with the exception of one time point. The 24-month results demonstrate that GATT is relatively safe and effective in treating various forms of open-angle glaucoma. The long-term results for GATT are relatively equivalent to those previously reported for GATT and ab externo trabeculotomy studies.

  3. The Frequency of Optical Coherence Tomography Testing in Glaucoma at a Single Academic Medical Center.

    PubMed

    Griffith, Joseph F; Goldberg, Jeffrey L

    2016-03-01

    To determine the frequency of optical coherence tomography (OCT) examinations compared with clinical examinations and visual field (VF) tests in patients with 5 types of glaucoma. A retrospective, longitudinal cohort study was conducted of 5154 patients treated between 2003 and 2010 at a single academic medical center. Patients were classified using billing records as having primary open-angle glaucoma, low-tension open-angle glaucoma (NTG), pigmentary open-angle glaucoma, chronic angle-closure glaucoma, or pseudoexfoliation glaucoma. Analysis of variance, χ test, and exact χ test were performed to identify associations between glaucoma type and test frequency. Pigmentary open-angle glaucoma and NTG patients had a higher rate of undergoing at least 2 VFs (94.4%, 94.9%), and chronic angle-closure glaucoma patients had a lower rate of undergoing at least 2 OCTs (25.3%) than all other glaucoma types. NTG patients also had the highest rate of undergoing at least 2 OCTs and at least 2 VFs (36.6%). Overall, the rate of clinical examinations (2.68 examinations/y) exceeded the rates of OCTs (1.39 examinations/y), which exceeded the rate of VF tests (1.24 tests/y). There were no differences in OCT frequency between glaucoma types (0.91 to 1.63 OCTs/y). Within each glaucoma diagnosis, patients had clinical examinations more frequently than OCTs and clinical examinations more frequently than VFs. Primary open-angle glaucoma and pseudoexfoliation glaucoma patients also had OCTs more frequently than VFs. More patients had at least 2 VF tests than at least 2 OCTs (4481 vs. 1679). The relative use of clinical examinations, VF testing, and OCT imaging varies among glaucoma diagnoses.

  4. Geometry and evolution of low-angle normal faults (LANF) within a Cenozoic high-angle rift system, Thailand: Implications for sedimentology and the mechanisms of LANF development

    NASA Astrophysics Data System (ADS)

    Morley, Chris K.

    2009-10-01

    At least eight examples of large (5-35 km heave), low-angle normal faults (LANFs, 20°-30° dip) occur in the Cenozoic rift basins of Thailand and laterally pass into high-angle extensional fault systems. Three large-displacement LANFs are found in late Oligocene-Miocene onshore rift basins (Suphan Buri, Phitsanulok, and Chiang Mai basins), they have (1) developed contemporaneous with, or after the onset of, high-angle extension, (2) acted as paths for magma and associated fluids, and (3) impacted sedimentation patterns. Displacement on low-angle faults appears to be episodic, marked by onset of lacustrine conditions followed by axial progradation of deltaic systems that infilled the lakes during periods of low or no displacement. The Chiang Mai LANF is a low-angle (15°-25°), high-displacement (15-35 km heave), ESE dipping LANF immediately east of the late early Miocene Doi Inthanon and Doi Suthep metamorphic core complexes. Early Cenozoic transpressional crustal thickening followed by the northward motion of India coupled with Burma relative to east Burma and Thailand (˜40-30 Ma) caused migmatization and gneiss dome uplift in the late Oligocene of the core complex region, followed by LANF activity. LANF displacement lasted 4-6 Ma during the early Miocene and possibly transported a late Oligocene-early Miocene high-angle rift system 35 km east. Other LANFs in Thailand have lower displacements and no associated metamorphic core complexes. The three LANFs were initiated as low-angle faults, not by isostatic rotation of high-angle faults. The low-angle dips appear to follow preexisting low-angle fabrics (thrusts, shear zones, and other low-angle ductile foliations) predominantly developed during Late Paleozoic and early Paleogene episodes of thrusting and folding.

  5. Radiographic comparison of surgical hip dislocation and hip arthroscopy for treatment of cam deformity in femoroacetabular impingement.

    PubMed

    Bedi, Asheesh; Zaltz, Ira; De La Torre, Katrina; Kelly, Bryan T

    2011-07-01

    Whether open or arthroscopic techniques are employed, the goal of femoroacetabular impingement (FAI) surgery is to achieve impingement-free range of motion. While arthroscopic approaches have improved and gained popularity, an objective evaluation of the surgical correction achieved with this approach compared with open surgery remains to be defined in the literature. This study was undertaken to compare the efficacy of arthroscopic osteoplasty and open surgical dislocation in treating FAI dysmorphology in a consecutive series of patients. Cohort study; Level of evidence, 3. Surgical treatment was performed in 60 male patients under 40 years of age for symptomatic FAI refractory to nonoperative management. Patients were matched (not randomized) to treatment groups: 30 patients (15 left and 15 right hips) underwent arthroscopic cam and/or rim osteoplasty with labral debridement and/or refixation by an arthroscopic surgeon; and 30 (14 left and 16 right hips) underwent open surgical dislocation, cam and/or rim osteoplasty, and labral debridement or refixation by a hip preservation surgeon. Anteroposterior (AP) pelvis and extended-neck (Dunn) lateral radiographs were obtained and the depth of resection and arc of resection were measured by assessment of anterior femoral head-neck offset, AP and lateral α angle, and β angle on preoperative and postoperative radiographs. In the arthroscopic group, the extended-neck lateral α angle was reduced by a mean of 17.2° (28.3%, P < .05), AP α angle was reduced by a mean of 12.6° (16.8%), anterior head-neck offset improved 5.0 mm (111%, P < .05), and β angle increased by a mean of 23.1°. In the open dislocation group, the extended-neck lateral α angle was reduced by a mean of 21.2° (30.7%, P < .05), AP α angle was reduced by a mean of 20.1° (25.7%), anterior head-neck offset improved 6.56 mm (108%, P < .05), and β angle increased by a mean of 18.35°. Arthroscopic osteoplasty can restore head-neck offset and achieve similar depth, arc, and proximal-distal resection with comparable efficacy to open surgical dislocation for anterior and anterosuperior cam and focal rim impingement deformity. The open technique, however, may allow greater correction of posterosuperior loss of femoral offset and may be favorable for FAI patterns that demonstrate considerable proximal femoral deformity on AP radiographs.

  6. Brain-Derived Neurotrophic Factor in Patients with Primary Open-Angle Glaucoma and Age-related Cataract.

    PubMed

    Shpak, Alexander A; Guekht, Alla B; Druzhkova, Tatiana A; Kozlova, Ksenia I; Gulyaeva, Natalia V

    2018-02-01

    To study brain-derived neurotrophic factor (BDNF) content in aqueous humor (AH), lacrimal fluid (LF), and blood serum (BS) in patients with age-related cataract and primary open-angle glaucoma (POAG). BDNF was studied in 57 patients with age-related cataract, 55 patients with POAG combined with cataract, and 29 healthy controls (one eye in each person). AH was sampled during cataract surgery. The levels of BDNF in LF and BS did not differ in cataract patients and controls. The concentration of BDNF (pg/mL) in patients with POAG and cataract was lower than in cataract patients in AH (35.2 ± 14.2 vs. 54.6 ± 29.6, P < 0.001), LF (78.0 ± 25.1 vs. 116.2 ± 43.1, P < 0.001), and BS (19230 ± 5960 vs. 22440 ± 7580, P < 0.02), while the AH/LF ratio was similar (0.46 ± 0.18 vs. 0.48 ± 0.19). The AH level of BDNF declined in early POAG and relatively increased in the next stages of the disease, inversely correlating with visual field index (Pearson's correlation coefficient r = -0.404, P = 0.002) and average retinal nerve fiber layer thickness (r = -0.322, P = 0.018). BDNF contents in LF and BS were also the lowest in early POAG. BDNF in AH strongly correlated with its content in LF (r = 0.66, P < 0.000). A formula was suggested to calculate the AH concentration of BDNF basing on its content in LF. BDNF contents are decreased in AH, LF, and BS of patients with POAG demonstrating a significant decrease in the early POAG and relative increase in the next stages of the disease. A strong correlation exists between BDNF contents in AH and LF.

  7. Hallux Valgus Correction Comparing Percutaneous Chevron/Akin (PECA) and Open Scarf/Akin Osteotomies.

    PubMed

    Lee, Moses; Walsh, James; Smith, Margaret M; Ling, Jeff; Wines, Andrew; Lam, Peter

    2017-08-01

    Minimally invasive surgery is being used increasingly, including for hallux valgus surgery. Despite the growing interest in minimally invasive procedures, there have been few publications on percutaneous chevron/akin (PECA) procedures, and no studies have been published comparing PECA to open scarf/akin osteotomies (SA). This was a prospective, randomized study of 50 patients undergoing operative correction of hallux valgus using one of 2 techniques (PECA vs open SA). Data were collected preoperatively and on 1 day, 2 weeks, 6 weeks, and 6 months postoperatively. Outcome measures include the American Orthopaedic Foot & Ankle Society Hallux-Metatarsophalangeal-Interphalangeal (AOFAS-HMI) Score, visual analog pain score, hallux valgus angle (HVA), and 1-2 intermetatarsal angle (IMA). Twenty-five patients underwent PECA procedures and 25 patients received SA procedures. Both groups showed significantly improved AOFAS-HMI scores after surgery (PECA group: 61.8 to 88.9, SA group: 57.3 to 84.1, P = .560) with comparable final scores. HVA and IMA also presented similar outcomes at final follow-up ( P = .520 and P = .270, respectively). However, the PECA group showed significantly lower pain level (VAS) in the early postoperative phase (postoperative day 1 to postoperative week 6, P < .001 and P = .004, respectively). No serious complications were observed in either group. Both groups showed comparable good to excellent clinical and radiologic outcomes at final follow-up. However, the PECA group had significantly less pain in the first 6 weeks following surgery. Level of Evidence Level II, prospective comparative study.

  8. Correlations between Preoperative Angle Parameters and Postoperative Unpredicted Refractive Errors after Cataract Surgery in Open Angle Glaucoma (AOD 500).

    PubMed

    Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun; Seong, Gong Je

    2017-03-01

    To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R²=0.404). Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors.

  9. Correlations between Preoperative Angle Parameters and Postoperative Unpredicted Refractive Errors after Cataract Surgery in Open Angle Glaucoma (AOD 500)

    PubMed Central

    Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun

    2017-01-01

    Purpose To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. Materials and Methods This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. Results In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R2=0.404). Conclusion Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors. PMID:28120576

  10. Predictors of Intraocular Pressure After Phacoemulsification in Primary Open-Angle Glaucoma Eyes with Wide Versus Narrower Angles (An American Ophthalmological Society Thesis)

    PubMed Central

    Lin, Shan C.; Masis, Marisse; Porco, Travis C.; Pasquale, Louis R.

    2017-01-01

    Purpose To assess if narrower-angle status and anterior segment optical coherence tomography (AS-OCT) parameters can predict intraocular pressure (IOP) drop in primary open-angle glaucoma (POAG) patients after cataract surgery. Methods This was a prospective case series of consecutive cataract surgery patients with POAG and no peripheral anterior synechiae (PAS) using a standardized postoperative management protocol. Preoperatively, patients underwent gonioscopy and AS-OCT. The same glaucoma medication regimen was resumed by 1 month. Potential predictors of IOP reduction included narrower-angle status by gonioscopy and angle-opening distance (AOD500) as well as other AS-OCT parameters. Mixed-effects regression adjusted for use of both eyes and other potential confounders. Results We enrolled 66 eyes of 40 glaucoma patients. The IOP reduction at 1 year was 4.2±3 mm Hg (26%, P<.001) in the narrower-angle group vs 2.2±3 mm Hg (14%, P<.001) in the wide-angle group (P=.027 for difference), as classified by gonioscopy. By AOD500 classification, the narrower-angle group had 3.4±3 mm Hg (21%, P<.001) reduction vs 2.5±3 mm Hg (16%, P<.001) in the wide-angle group (P=.031 for difference). When the entire cohort was assessed, iris thickness, iris area, and lens vault were correlated with increasing IOP reduction at 1 year (P<.05 for all). Conclusions In POAG eyes, cataract surgery lowered IOP to a greater degree in the narrower-angle group than in the wide-angle group, and parameters relating to iris thickness and area, as well as lens vault, were correlated with IOP reduction. These findings can guide ophthalmologists in their selection of cataract surgery as a potential management option. PMID:29147104

  11. Predictors of Intraocular Pressure After Phacoemulsification in Primary Open-Angle Glaucoma Eyes with Wide Versus Narrower Angles (An American Ophthalmological Society Thesis).

    PubMed

    Lin, Shan C; Masis, Marisse; Porco, Travis C; Pasquale, Louis R

    2017-08-01

    To assess if narrower-angle status and anterior segment optical coherence tomography (AS-OCT) parameters can predict intraocular pressure (IOP) drop in primary open-angle glaucoma (POAG) patients after cataract surgery. This was a prospective case series of consecutive cataract surgery patients with POAG and no peripheral anterior synechiae (PAS) using a standardized postoperative management protocol. Preoperatively, patients underwent gonioscopy and AS-OCT. The same glaucoma medication regimen was resumed by 1 month. Potential predictors of IOP reduction included narrower-angle status by gonioscopy and angle-opening distance (AOD500) as well as other AS-OCT parameters. Mixed-effects regression adjusted for use of both eyes and other potential confounders. We enrolled 66 eyes of 40 glaucoma patients. The IOP reduction at 1 year was 4.2±3 mm Hg (26%, P <.001) in the narrower-angle group vs 2.2±3 mm Hg (14%, P <.001) in the wide-angle group ( P =.027 for difference), as classified by gonioscopy. By AOD500 classification, the narrower-angle group had 3.4±3 mm Hg (21%, P <.001) reduction vs 2.5±3 mm Hg (16%, P <.001) in the wide-angle group ( P =.031 for difference). When the entire cohort was assessed, iris thickness, iris area, and lens vault were correlated with increasing IOP reduction at 1 year ( P <.05 for all). In POAG eyes, cataract surgery lowered IOP to a greater degree in the narrower-angle group than in the wide-angle group, and parameters relating to iris thickness and area, as well as lens vault, were correlated with IOP reduction. These findings can guide ophthalmologists in their selection of cataract surgery as a potential management option.

  12. Some Characteristics of Fuel Sprays from Open Nozzles

    NASA Technical Reports Server (NTRS)

    Rothrock, A M; Lee, D W

    1930-01-01

    The penetration and cone-angle of fuel sprays from open nozzles were recorded with the NACA Spray Photography Equipment. The results show that for injection systems in which the rate of pressure rise at the discharge orifice is high, open nozzles give spray-tip velocities and penetrations which compare favorably with those of closed nozzles. The spray cone-angle was the same for all tests, although open nozzles having different orifice diameters were used, and one nozzle was used both as an open and as a closed nozzle. In designing a fuel system using open nozzles, particular care must be taken to avoid air pockets. The check valve should be placed close to the discharge orifice.

  13. Vascular tone pathway polymorphisms in relation to primary open-angle glaucoma.

    PubMed

    Kang, J H; Loomis, S J; Yaspan, B L; Bailey, J C; Weinreb, R N; Lee, R K; Lichter, P R; Budenz, D L; Liu, Y; Realini, T; Gaasterland, D; Gaasterland, T; Friedman, D S; McCarty, C A; Moroi, S E; Olson, L; Schuman, J S; Singh, K; Vollrath, D; Wollstein, G; Zack, D J; Brilliant, M; Sit, A J; Christen, W G; Fingert, J; Forman, J P; Buys, E S; Kraft, P; Zhang, K; Allingham, R R; Pericak-Vance, M A; Richards, J E; Hauser, M A; Haines, J L; Wiggs, J L; Pasquale, L R

    2014-06-01

    Vascular perfusion may be impaired in primary open-angle glaucoma (POAG); thus, we evaluated a panel of markers in vascular tone-regulating genes in relation to POAG. We used Illumina 660W-Quad array genotype data and pooled P-values from 3108 POAG cases and 3430 controls from the combined National Eye Institute Glaucoma Human Genetics Collaboration consortium and Glaucoma Genes and Environment studies. Using information from previous literature and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathways, we compiled single-nucleotide polymorphisms (SNPs) in 186 vascular tone-regulating genes. We used the 'Pathway Analysis by Randomization Incorporating Structure' analysis software, which performed 1000 permutations to compare the overall pathway and selected genes with comparable randomly generated pathways and genes in their association with POAG. The vascular tone pathway was not associated with POAG overall or POAG subtypes, defined by the type of visual field loss (early paracentral loss (n=224 cases) or only peripheral loss (n=993 cases)) (permuted P≥0.20). In gene-based analyses, eight were associated with POAG overall at permuted P<0.001: PRKAA1, CAV1, ITPR3, EDNRB, GNB2, DNM2, HFE, and MYL9. Notably, six of these eight (the first six listed) code for factors involved in the endothelial nitric oxide synthase activity, and three of these six (CAV1, ITPR3, and EDNRB) were also associated with early paracentral loss at P<0.001, whereas none of the six genes reached P<0.001 for peripheral loss only. Although the assembled vascular tone SNP set was not associated with POAG, genes that code for local factors involved in setting vascular tone were associated with POAG.

  14. Comparison of diagnostic capability of macular ganglion cell complex and retinal nerve fiber layer among primary open angle glaucoma, ocular hypertension, and normal population using Fourier-domain optical coherence tomography and determining their functional correlation in Indian population

    PubMed Central

    Barua, Nabanita; Sitaraman, Chitra; Goel, Sonu; Chakraborti, Chandana; Mukherjee, Sonai; Parashar, Hemandra

    2016-01-01

    Context: Analysis of diagnostic ability of macular ganglionic cell complex and retinal nerve fiber layer (RNFL) in glaucoma. Aim: To correlate functional and structural parameters and comparing predictive value of each of the structural parameters using Fourier-domain (FD) optical coherence tomography (OCT) among primary open angle glaucoma (POAG) and ocular hypertension (OHT) versus normal population. Setting and Design: Single centric, cross-sectional study done in 234 eyes. Materials and Methods: Patients were enrolled in three groups: POAG, ocular hypertensive and normal (40 patients in each group). After comprehensive ophthalmological examination, patients underwent standard automated perimetry and FD-OCT scan in optic nerve head and ganglion cell mode. The relationship was assessed by correlating ganglion cell complex (GCC) parameters with mean deviation. Results were compared with RNFL parameters. Statistical Analysis: Data were analyzed with SPSS, analysis of variance, t-test, Pearson's coefficient, and receiver operating curve. Results: All parameters showed strong correlation with visual field (P < 0.001). Inferior GCC had highest area under curve (AUC) for detecting glaucoma (0.827) in POAG from normal population. However, the difference was not statistically significant (P > 0.5) when compared with other parameters. None of the parameters showed significant diagnostic capability to detect OHT from normal population. In diagnosing early glaucoma from OHT and normal population, only inferior GCC had statistically significant AUC value (0.715). Conclusion: In this study, GCC and RNFL parameters showed equal predictive capability in perimetric versus normal group. In early stage, inferior GCC was the best parameter. In OHT population, single day cross-sectional imaging was not valuable. PMID:27221682

  15. Case report: imaging and treatment of ophthalmic manifestations in oculodentodigital dysplasia.

    PubMed

    Mosaed, Sameh; Jacobsen, Bradley H; Lin, Ken Young

    2016-01-07

    Diagnostic and surgical management of severe chronic angle- closure glaucoma secondary to ciliary body cysts can be difficult to manage in a patient with oculodentodigital dysplasia. A 6-year old girl with oculodentodigital dysplasia, with progressive chronic angle- closure glaucoma secondary to ciliary body cysts presented to our clinic. The initial examination revealed counting fingers vision in the left eye. Intraocular pressure (IOP), as assessed by tonopen, was 31 mm Hg. Ultrasound biomicroscopy revealed ciliary body cysts in the left eye, and gonioscopy confirmed chronic angle closure. A tube shunt was placed to control the elevated IOP. A year after her tube shunt placement in the left eye, ultrasound biomiscropy was performed on her right eye and showed no ciliary body cysts. Gonioscopy in the right eye revealed an open angle to the ciliary body band. Subsequent serial gonioscopy every 3 months showed gradual narrowing of the right eye angle and finally three-and-a-half years after tube placement of the left eye, her right eye IOP became uncontrolled with medications alone and a tube shunt was similarly placed in the right eye. Intraoperative ultrasound biomicroscopy performed at the time of the right eye tube shunt revealed extensive ciliary body cysts in the right eye. Her IOP in both eyes have been well controlled since the placement of tube shunts. This is one of the first reported cases of severe chronic angle- closure glaucoma secondary to ciliary body cysts in a patient with oculodentodigital dysplasia. We believe that early screening for ciliary body cysts is important in patients with oculodentodigital dysplasia.

  16. MOJAVE - XIV. Shapes and opening angles of AGN jets

    NASA Astrophysics Data System (ADS)

    Pushkarev, A. B.; Kovalev, Y. Y.; Lister, M. L.; Savolainen, T.

    2017-07-01

    We present 15 GHz stacked VLBA images of 373 jets associated with active galactic nuclei (AGNs) having at least five observing epochs within a 20 yr time interval 1994-2015 from the Monitoring Of Jets in Active galactic nuclei with VLBA Experiments (MOJAVE) programme and/or its precursor, the 2-cm VLBA Survey. These data are supplemented by 1.4 GHz single-epoch VLBA observations of 135 MOJAVE AGNs to probe larger scale jet structures. The typical jet geometry is found to be close to conical on scales from hundreds to thousands of parsecs, while a number of galaxies show quasi-parabolic streamlines on smaller scales. A true jet geometry in a considerable fraction of AGNs appears only after stacking epochs over several years. The jets with significant radial accelerated motion undergo more active collimation. We have analysed total intensity jet profiles transverse to the local jet ridgeline and derived both apparent and intrinsic opening angles of the flows, with medians of 21.5° and 1.3°, respectively. The Fermi LAT-detected gamma-ray AGNs in our sample have, on average, wider apparent and narrower intrinsic opening angle, and smaller viewing angle than non-LAT-detected AGNs. We have established a highly significant correlation between the apparent opening angle and gamma-ray luminosity, driven by Doppler beaming and projection effects.

  17. Gravity field error analysis for pendulum formations by a semi-analytical approach

    NASA Astrophysics Data System (ADS)

    Li, Huishu; Reubelt, Tilo; Antoni, Markus; Sneeuw, Nico

    2017-03-01

    Many geoscience disciplines push for ever higher requirements on accuracy, homogeneity and time- and space-resolution of the Earth's gravity field. Apart from better instruments or new observables, alternative satellite formations could improve the signal and error structure compared to Grace. One possibility to increase the sensitivity and isotropy by adding cross-track information is a pair of satellites flying in a pendulum formation. This formation contains two satellites which have different ascending nodes and arguments of latitude, but have the same orbital height and inclination. In this study, the semi-analytical approach for efficient pre-mission error assessment is presented, and the transfer coefficients of range, range-rate and range-acceleration gravitational perturbations are derived analytically for the pendulum formation considering a set of opening angles. The new challenge is the time variations of the opening angle and the range, leading to temporally variable transfer coefficients. This is solved by Fourier expansion of the sine/cosine of the opening angle and the central angle. The transfer coefficients are further applied to assess the error patterns which are caused by different orbital parameters. The simulation results indicate that a significant improvement in accuracy and isotropy is obtained for small and medium initial opening angles of single polar pendulums, compared to Grace. The optimal initial opening angles are 45° and 15° for accuracy and isotropy, respectively. For a Bender configuration, which is constituted by a polar Grace and an inclined pendulum in this paper, the behaviour of results is dependent on the inclination (prograde vs. retrograde) and on the relative baseline orientation (left or right leading). The simulation for a sun-synchronous orbit shows better results for the left leading case.

  18. Flow field and performance characteristics of combustor diffusers: A basic study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hestermann, R.; Kim, S.; Ben Khaled, A.

    1995-10-01

    Results of a detailed study concerning the influence of geometric as well as fluid mechanic parameters o the performance of a plane model combustor diffuser in cold flow are presented. For a qualitative insight into the complex flow field inside the prediffuser, the sudden expansion region, and the flow field around the flame tube dome, results of a flow visualization study with the hydrogen bubble method as well as with the ink jet method are presented for different opening angles of the prediffuser and for different flame tube distances. Also, quantitative data from detailed measurements with LDV and conventional pressuremore » probes in a geometrically similar air-driven setup are presented. These data clearly demonstrate the effect of boundary layer thickness as well as the influence of different turbulence levels at the entry of the prediffuser on the performance characteristics of combustor diffusers. The possibility of getting an unseparated flow field inside the prediffuser even at large opening angles by appropriately matching the diffuser`s opening angle and the flame tube distance is demonstrated. Also, for flows with an increased turbulence level at the entrance--all other conditions held constant--an increased opening angle can be realized without experiencing flow separation. The comparison of the experimental data with predictions utilizing a finite-volume-code based on a body-fitted coordinate system for diffusers with an included total opening angle less than 18 deg demonstrates the capability of describing the flow field in combustor diffusers with reasonable accuracy.« less

  19. Hong's grading for evaluating anterior chamber angle width.

    PubMed

    Kim, Seok Hwan; Kang, Ja Heon; Park, Ki Ho; Hong, Chul

    2012-11-01

    To compare Hong's grading method with anterior segment optical coherence tomography (AS-OCT), gonioscopy, and the dark-room prone-position test (DRPT) for evaluating anterior chamber width. The anterior chamber angle was graded using Hong's grading method, and Hong's angle width was calculated from the arctangent of Hong's grades. The correlation between Hong's angle width and AS-OCT parameters was analyzed. The area under the receiver operating characteristic curve (AUC) for Hong's grading method when discriminating between narrow and open angles as determined by gonioscopy was calculated. Correlation analysis was performed between Hong's angle width and intraocular pressure (IOP) changes determined by DRPT. A total of 60 subjects were enrolled. Of these subjects, 53.5 % had a narrow angle. Hong's angle width correlated significantly with the AS-OCT parameters (r = 0.562-0.719, P < 0.01). A Bland-Altman plot showed relatively good agreement between Hong's angle width and the angle width obtained by AS-OCT. The ability of Hong's grading method to discriminate between open and narrow angles was good (AUC = 0.868, 95 % CI 0.756-0.942). A significant linear correlation was found between Hong's angle width and IOP change determined by DRPT (r = -0.761, P < 0.01). Hong's grading method is useful for detecting narrow angles. Hong's grading correlated well with AS-OCT parameters and DRPT.

  20. Mechanical strength assessment of a drilled hole in the contralateral cortex at the end of the open wedge for high tibial osteotomy.

    PubMed

    Diffo Kaze, Arnaud; Maas, Stefan; Hoffmann, Alexander; Pape, Dietrich

    2017-12-01

    This study aimed to investigate, by means of finite element analysis, the effect of a drill hole at the end of a horizontal osteotomy to reduce the risk of lateral cortex fracture while performing an opening wedge high tibial osteotomy (OWHTO). The question was whether drilling a hole relieves stress and increases the maximum correction angle without fracture of the lateral cortex depending on the ductility of the cortical bone. Two different types of osteotomy cuts were considered; one with a drill hole (diameter 5 mm) and the other without the hole. The drill holes were located about 20 mm distally to the tibial plateau and 6 mm medially to the lateral cortex, such that the minimal thickness of the contralateral cortical bone was 5 mm. Based on finite element calculations, two approaches were used to compare the two types of osteotomy cuts considered: (1) Assessing the static strength using local stresses following the idea of the FKM-guideline, subsequently referred to as the "FKM approach" and (2) limiting the total strain during the opening of the osteotomy wedge, subsequently referred to as "strain approach". A critical opening angle leading to crack initiation in the opposite lateral cortex was determined for each approach and was defined as comparative parameter. The relation to bone aging was investigated by considering the material parameters of cortical bones from young and old subjects. The maximum equivalent (von-Mises) stress was smaller for the cases with a drill hole at the end of the osteotomy cut. The critical angle was approximately 1.5 times higher for the specimens with a drill hole compared to those without. This corresponds to an average increase of 50%. The calculated critical angle for all approaches is below 5°. The critical angle depends on the used approach, on patient's age and assumed ductility of the cortical bone. Drilling a hole at the end of the osteotomy reduces the stresses in the lateral cortex and increases the critical opening angle prior to cracking of the opposite cortex in specimen with small correction angles. But the difference from having a drill hole or not is not so significant, especially for older patients. The ductility of the cortical bone is the decisive parameter for the critical opening angle.

  1. Shape-based human detection for threat assessment

    NASA Astrophysics Data System (ADS)

    Lee, Dah-Jye; Zhan, Pengcheng; Thomas, Aaron; Schoenberger, Robert B.

    2004-07-01

    Detection of intrusions for early threat assessment requires the capability of distinguishing whether the intrusion is a human, an animal, or other objects. Most low-cost security systems use simple electronic motion detection sensors to monitor motion or the location of objects within the perimeter. Although cost effective, these systems suffer from high rates of false alarm, especially when monitoring open environments. Any moving objects including animals can falsely trigger the security system. Other security systems that utilize video equipment require human interpretation of the scene in order to make real-time threat assessment. Shape-based human detection technique has been developed for accurate early threat assessments for open and remote environment. Potential threats are isolated from the static background scene using differential motion analysis and contours of the intruding objects are extracted for shape analysis. Contour points are simplified by removing redundant points connecting short and straight line segments and preserving only those with shape significance. Contours are represented in tangent space for comparison with shapes stored in database. Power cepstrum technique has been developed to search for the best matched contour in database and to distinguish a human from other objects from different viewing angles and distances.

  2. 46 CFR 172.150 - Survival conditions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... waterline, in the final condition of sinkage, heel, and trim, must be below the lower edge of openings such.... (5) Side scuttles of the non-opening type. (b) Heel angle. (1) Except as described in paragraph (b)(2) of this section, the maximum angle of heel must not exceed 15 degrees (17 degrees if no part of the...

  3. 46 CFR 172.150 - Survival conditions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... waterline, in the final condition of sinkage, heel, and trim, must be below the lower edge of openings such.... (5) Side scuttles of the non-opening type. (b) Heel angle. (1) Except as described in paragraph (b)(2) of this section, the maximum angle of heel must not exceed 15 degrees (17 degrees if no part of the...

  4. Ocular Biometrics of Myopic Eyes With Narrow Angles.

    PubMed

    Chong, Gabriel T; Wen, Joanne C; Su, Daniel Hsien-Wen; Stinnett, Sandra; Asrani, Sanjay

    2016-02-01

    The purpose of this study was to compare the ocular biometrics between myopic patients with and without narrow angles. Patients with a stable myopic refraction (myopia worse than -1.00 D spherical equivalent) were prospectively recruited. Angle status was assessed using gonioscopy and biometric measurements were performed using an anterior segment optical coherence tomography and an IOLMaster. A total of 29 patients (58 eyes) were enrolled with 13 patients (26 eyes) classified as having narrow angles and 16 patients (32 eyes) classified as having open angles. Baseline demographics of age, sex, and ethnicity did not differ significantly between the 2 groups. The patients with narrow angles were on average older than those with open angles but the difference did not reach statistical significance (P=0.12). The central anterior chamber depth was significantly less in the eyes with narrow angles (P=0.05). However, the average lens thickness, although greater in the eyes with narrow angles, did not reach statistical significance (P=0.10). Refractive error, axial lengths, and iris thicknesses did not differ significantly between the 2 groups (P=0.32, 0.47, 0.15). Narrow angles can occur in myopic eyes. Routine gonioscopy is therefore recommended for all patients regardless of refractive error.

  5. Early Mission Maneuver Operations for the Deep Space Climate Observatory

    NASA Technical Reports Server (NTRS)

    Roberts, Craig; Case, Sara; Reagoso, John

    2015-01-01

    DSCOVR Lissajous Orbit sized such that orbit track never extends beyond 15 degrees from Earth-Sun line (as seen from Earth). Requiring delta-V maneuvers, control orbit to obey a Solar Exclusion Zone (SEZ) cone of half-angle 4 degrees about the Earth-Sun line. Spacecraft should never be less than 4 degrees from solar center as seen from Earth. Following Lissajous Orbit Insertion (LOI), DSCOVR should be in an opening phase that just skirts the 4-degree SEZ. Maximizes time to the point where a closing Lissajous will require avoidance maneuvers to keep it out of the SEZ. Station keeping maneuvers should take no more than 15 minutes

  6. Laser-driven interactions and resultant instabilities in materials with high dielectric constant

    NASA Astrophysics Data System (ADS)

    Rajpoot, Moolchandra; Dixit, Sanjay

    2015-07-01

    An analytical investigation of nonlinear interactions resulting in parametric amplification of acoustic wave is made by obtaining the dispersion relation using hydrodynamic model of inhomogeneous plasma by applying large static field at an arbitrary angle with the pump wave. The investigation shows that many early studies have neglected dependence of dielectric constant on deformation of materials but deformation of materials does infect depends on the dielectric constant of medium. Thus we have assumed to high dielectric material like BaTiO3 which resulted in substantially high growth rate of threshold electric field which opens a new dimension to study nonlinear interactions and instabilities.

  7. Energy Landscapes for the Self-Assembly of Supramolecular Polyhedra

    NASA Astrophysics Data System (ADS)

    Russell, Emily R.; Menon, Govind

    2016-06-01

    We develop a mathematical model for the energy landscape of polyhedral supramolecular cages recently synthesized by self-assembly (Sun et al. in Science 328:1144-1147, 2010). Our model includes two essential features of the experiment: (1) geometry of the organic ligands and metallic ions; and (2) combinatorics. The molecular geometry is used to introduce an energy that favors square-planar vertices (modeling {Pd}^{2+} ions) and bent edges with one of two preferred opening angles (modeling boomerang-shaped ligands of two types). The combinatorics of the model involve two-colorings of edges of polyhedra with four-valent vertices. The set of such two-colorings, quotiented by the octahedral symmetry group, has a natural graph structure and is called the combinatorial configuration space. The energy landscape of our model is the energy of each state in the combinatorial configuration space. The challenge in the computation of the energy landscape is a combinatorial explosion in the number of two-colorings of edges. We describe sampling methods based on the symmetries of the configurations and connectivity of the configuration graph. When the two preferred opening angles encompass the geometrically ideal angle, the energy landscape exhibits a very low-energy minimum for the most symmetric configuration at equal mixing of the two angles, even when the average opening angle does not match the ideal angle.

  8. Satellite-Tracking Millimeter-Wave Reflector Antenna System For Mobile Satellite-Tracking

    NASA Technical Reports Server (NTRS)

    Densmore, Arthur C. (Inventor); Jamnejad, Vahraz (Inventor); Woo, Kenneth E. (Inventor)

    2001-01-01

    A miniature dual-band two-way mobile satellite-tracking antenna system mounted on a movable vehicle includes a miniature parabolic reflector dish having an elliptical aperture with major and minor elliptical axes aligned horizontally and vertically, respectively, to maximize azimuthal directionality and minimize elevational directionality to an extent corresponding to expected pitch excursions of the movable ground vehicle. A feed-horn has a back end and an open front end facing the reflector dish and has vertical side walls opening out from the back end to the front end at a lesser horn angle and horizontal top and bottom walls opening out from the back end to the front end at a greater horn angle. An RF circuit couples two different signal bands between the feed-horn and the user. An antenna attitude controller maintains an antenna azimuth direction relative to the satellite by rotating it in azimuth in response to sensed yaw motions of the movable ground vehicle so as to compensate for the yaw motions to within a pointing error angle. The controller sinusoidally dithers the antenna through a small azimuth dither angle greater than the pointing error angle while sensing a signal from the satellite received at the reflector dish, and deduces the pointing angle error from dither-induced fluctuations in the received signal.

  9. A satellite-tracking millimeter-wave reflector antenna system for mobile satellite-tracking

    NASA Technical Reports Server (NTRS)

    Densmore, Arthur C. (Inventor); Jamnejad, Vahraz (Inventor); Woo, Kenneth E. (Inventor)

    1995-01-01

    A miniature dual-band two-way mobile satellite tracking antenna system mounted on a movable ground vehicle includes a miniature parabolic reflector dish having an elliptical aperture with major and minor elliptical axes aligned horizontally and vertically, respectively, to maximize azimuthal directionality and minimize elevational directionality to an extent corresponding to expected pitch excursions of the movable ground vehicle. A feed-horn has a back end and an open front end facing the reflector dish and has vertical side walls opening out from the back end to the front end at a lesser horn angle and horizontal top and bottom walls opening out from the back end to the front end at a greater horn angle. An RF circuit couples two different signal bands between the feed-horn and the user. An antenna attitude controller maintains an antenna azimuth direction relative to the satellite by rotating it in azimuth in response to sensed yaw motions of the movable ground vehicle so as to compensate for the yaw motions to within a pointing error angle. The controller sinusoidally dithers the antenna through a small azimuth dither angle greater than the pointing error angle while sensing a signal from the satellite received at the reflector dish, and deduces the pointing angle error from dither-induced fluctuations in the received signal.

  10. Characteristics of Upper Quadrant Posture of Young Women with Temporomandibular Disorders

    PubMed Central

    Uritani, Daisuke; Kawakami, Tetsuji; Inoue, Tomohiro; Kirita, Tadaaki

    2014-01-01

    [Purpose] This study aimed to investigate the characteristics of upper quadrant posture of young women with temporomandibular disorders. [Subjects] The participants were 19 female patients with temporomandibular disorders (patient group: mean age, 30.1 years) and 14 controls (control group: mean age, 24.6 years). [Methods] Outcome measures were the neck inclination angle (formed by a line connecting C7 and the ear tragus with a horizontal line), the angle of the shoulder (formed by a line connecting C7 and the acromial angle with a horizontal line), the cranial rotation angle (formed by a line connecting the ear tragus and the corner of the eye with a horizontal line), and the neck-length/shoulder-width ratio [the ratio of the neck length (from C7 to the tragus) to the width of the shoulder between the acromial angle]. The maximum range of mouth opening was measured using a scale. [Results] The neck inclination angle and maximum range of mouth opening were significantly smaller in the patient group than in the control group. No significant differences were observed in the other outcome measures between the two groups. [Conclusion] Temporomandibular disorders with limited mouth opening in young females are associated with the head position relative to the trunk. PMID:25276038

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldstein, Adam; Connaughton, Valerie; Briggs, Michael S.

    We present a method to estimate the jet opening angles of long duration gamma-ray bursts (GRBs) using the prompt gamma-ray energetics and an inversion of the Ghirlanda relation, which is a correlation between the time-integrated peak energy of the GRB prompt spectrum and the collimation-corrected energy in gamma-rays. The derived jet opening angles using this method and detailed assumptions match well with the corresponding inferred jet opening angles obtained when a break in the afterglow is observed. Furthermore, using a model of the predicted long GRB redshift probability distribution observable by the Fermi Gamma-ray Burst Monitor (GBM), we estimate themore » probability distributions for the jet opening angle and rest-frame energetics for a large sample of GBM GRBs for which the redshifts have not been observed. Previous studies have only used a handful of GRBs to estimate these properties due to the paucity of observed afterglow jet breaks, spectroscopic redshifts, and comprehensive prompt gamma-ray observations, and we potentially expand the number of GRBs that can be used in this analysis by more than an order of magnitude. In this analysis, we also present an inferred distribution of jet breaks which indicates that a large fraction of jet breaks are not observable with current instrumentation and observing strategies. We present simple parameterizations for the jet angle, energetics, and jet break distributions so that they may be used in future studies.« less

  12. Cross Cell Sandwich Core

    NASA Technical Reports Server (NTRS)

    Ford, Donald B. (Inventor)

    2004-01-01

    A sandwich core comprises two faceplates separated by a plurality of cells. The cells are comprised of walls positioned at oblique angles relative to a perpendicular axis extending through the faceplates. The walls preferably form open cells and are constructed from open cells and are constructed from rows of ribbons. The walls may be obliquely angled relative to more than one plane extending through the perpendicular axis.

  13. Heterogeneous growth-induced prestrain in the heart

    PubMed Central

    Genet, M.; Rausch, M.; Lee, L.C.; Choy, S.; Zhao, X.; Kassab, G.S.; Kozerke, S.; Guccione, J.M.; Kuhl, E.

    2015-01-01

    Even when entirely unloaded, biological structures are not stress-free, as shown by Y.C. Fung’s seminal opening angle experiment on arteries and the left ventricle. As a result of this prestrain, subject-specific geometries extracted from medical imaging do not represent an unloaded reference configuration necessary for mechanical analysis, even if the structure is externally unloaded. Here we propose a new computational method to create physiological residual stress fields in subject-specific left ventricular geometries using the continuum theory of fictitious configurations combined with a fixed-point iteration. We also reproduced the opening angle experiment on four swine models, to characterize the range of normal opening angle values. The proposed method generates residual stress fields which can reliably reproduce the range of opening angles between 8.7±1.8 and 16.6 ± 13.7 as measured experimentally. We demonstrate that including the effects of prestrain reduces the left ventricular stiffness by up to 40%, thus facilitating the ventricular filling, which has a significant impact on cardiac function. This method can improve the fidelity of subject-specific models to improve our understanding of cardiac diseases and to optimize treatment options. PMID:25913241

  14. Refraction and scattering of sound by a shear layer

    NASA Technical Reports Server (NTRS)

    Schlinker, R. H.; Amiet, R. K.

    1980-01-01

    The angle and amplitude changes for acoustic waves refracted by a circular open jet shear layer were determined. The generalized refraction theory was assessed experimentally for on axis and off axis acoustic source locations as source frequency varied from 1 kHz to 10 kHz and free stream Mach number varied from 0.1 to 0.4. Angle and amplitude changes across the shear layer show good agreement with theory. Experiments confirm that the refraction theory is independent of shear layer thickness, acoustic source frequency, and source type. A generalized theory is, thus, available for correcting far field noise data acquired in open jet test facilities. The effect of discrete tone scattering by the open jet turbulent shear layer was also studied. Scattering effects were investigated over the same Mach number range as frequency varied from 5 kHz to 15 kHz. Attenuation of discrete tone amplitude and tone broadening were measured as a function of acoustic source position and radiation angle. Scattering was found to be stronger at angles close to the open jet axis than at 90 deg, and becomes stronger as the acoustic source position shifts downstream. A scattering analysis provided an estimate of the onset of discrete tone scattering.

  15. Retrobulbar hemodynamic parameters in men and women with open angle glaucoma.

    PubMed

    Marjanović, Ivan; Marjanović, Marija; Gvozdenović, Ranko; Risović, Dušica

    2014-12-01

    Several factors may have influence on systemic circulation. Additionally, peripheral circulation also demonstrates sex differences, in young women presenting significantly lower finger blood flow in comparison to men of the same age, a finding that disappears in women after menopause. The aim of this study was to compare the retrobulbar hemodynamic parameters measured by means of color Doppler imaging in women and men with open-angle glaucoma and elevated intraocular pressure. A total of 52 eyes from 52 open-angle glaucoma (OAG) patients, with elevated intraocular pressure (lOP), were included in this cross-sectional study. Peak-systolic velocity (PSV), end-diastolic velocity (EDV), and Pourcelot resistivity index (RI) were assessed in the ophtalmic artery (OA), central retinal artery (CRA), and posterior cilliary arteries (PCA). IOP was measured both with Goldmann Applanation tonometer (GAT) and with the dynamic contour tonometer (DCT), three times respectively. Ocular pulse amplitude (OPA) appeared during the DCT measurement. The retrobulbar hemodynamic parameters did not show any difference between men and post-menopausal women. The results of our study did not find any difference between sexes in patients with open-angle glaucoma and elevated intraocular pressure.

  16. Hiding an elephant: heavy sterile neutrino with large mixing angle does not contradict cosmology

    NASA Astrophysics Data System (ADS)

    Bezrukov, F.; Chudaykin, A.; Gorbunov, D.

    2017-06-01

    We study a model of a keV-scale sterile neutrino with a relatively large mixing with the Standard Model sector. Usual considerations predict active generation of such particles in the early Universe, which leads to constraints from the total Dark Matter density and absence of X-ray signal from sterile neutrino decay. These bounds together may deem any attempt of creation of the keV scale sterile neutrino in the laboratory unfeasible. We argue that for models with a hidden sector coupled to the sterile neutrino these bounds can be evaded, opening new perspectives for the direct studies at neutrino experiments such as Troitsk ν-mass and KATRIN. We estimate the generation of sterile neutrinos in scenarios with the hidden sector dynamics keeping the sterile neutrinos either massless or superheavy in the early Universe. In both cases the generation by oscillations from active neutrinos in plasma is suppressed.

  17. Accurate Analysis of Target Characteristic in Bistatic SAR Images: A Dihedral Corner Reflectors Case.

    PubMed

    Ao, Dongyang; Li, Yuanhao; Hu, Cheng; Tian, Weiming

    2017-12-22

    The dihedral corner reflectors are the basic geometric structure of many targets and are the main contributions of radar cross section (RCS) in the synthetic aperture radar (SAR) images. In stealth technologies, the elaborate design of the dihedral corners with different opening angles is a useful approach to reduce the high RCS generated by multiple reflections. As bistatic synthetic aperture sensors have flexible geometric configurations and are sensitive to the dihedral corners with different opening angles, they specially fit for the stealth target detections. In this paper, the scattering characteristic of dihedral corner reflectors is accurately analyzed in bistatic synthetic aperture images. The variation of RCS with the changing opening angle is formulated and the method to design a proper bistatic radar for maximizing the detection capability is provided. Both the results of the theoretical analysis and the experiments show the bistatic SAR could detect the dihedral corners, under a certain bistatic angle which is related to the geometry of target structures.

  18. Accurate Analysis of Target Characteristic in Bistatic SAR Images: A Dihedral Corner Reflectors Case

    PubMed Central

    Ao, Dongyang; Hu, Cheng; Tian, Weiming

    2017-01-01

    The dihedral corner reflectors are the basic geometric structure of many targets and are the main contributions of radar cross section (RCS) in the synthetic aperture radar (SAR) images. In stealth technologies, the elaborate design of the dihedral corners with different opening angles is a useful approach to reduce the high RCS generated by multiple reflections. As bistatic synthetic aperture sensors have flexible geometric configurations and are sensitive to the dihedral corners with different opening angles, they specially fit for the stealth target detections. In this paper, the scattering characteristic of dihedral corner reflectors is accurately analyzed in bistatic synthetic aperture images. The variation of RCS with the changing opening angle is formulated and the method to design a proper bistatic radar for maximizing the detection capability is provided. Both the results of the theoretical analysis and the experiments show the bistatic SAR could detect the dihedral corners, under a certain bistatic angle which is related to the geometry of target structures. PMID:29271917

  19. --No Title--

    Science.gov Websites

    : "\\f106"; /* open - switch to fa-angle-up */ } @media(min-width:768px) { /* top level open */ } } /* top level open hover */ .navbar-dark .navbar-nav > li.open > a:hover, .navbar-dark .navbar-nav :768px) { /* top level open hover desktop*/ .navbar-dark .navbar-nav > li.open > a:hover, .navbar

  20. Gonioscopy assisted transluminal trabeculotomy: an ab interno circumferential trabeculotomy for the treatment of primary congenital glaucoma and juvenile open angle glaucoma.

    PubMed

    Grover, Davinder S; Smith, Oluwatosin; Fellman, Ronald L; Godfrey, David G; Butler, Michelle R; Montes de Oca, Ildamaris; Feuer, William J

    2015-08-01

    To introduce a novel ab interno 360° trabeculotomy for treating primary congenital glaucoma (PCG) and juvenile open angle glaucoma (JOAG) and report preliminary results. A retrospective chart review of patients who underwent a gonioscopy assisted transluminal trabeculotomy (GATT) procedure by four of the authors (DSG, OS, RLF and DGG) between October 2011 and October 2013. The surgery was performed in patients ≤30 years old with a dysgenic anterior segment angle and uncontrolled PCG and JOAG. Fourteen eyes of 10 patients underwent GATT with follow-up >12 months (12-33 months; mean 20.4). Patients ranged in age from 17 months to 30 years (mean=18.4 years), and five (50%) were female patients. No complications occurred during or following surgery except for early postoperative hyphema in five (36%) of eyes, all cleared by 1 month. The mean intraocular pressure (IOP) decreased from 27.3 to 14.8 mm Hg and the mean number of medications required decreased from 2.6 to 0.86. Five eyes had a drop in IOP ≥15 mm Hg (range 15-39). The preliminary results and safety for GATT, a minimally invasive conjunctival sparing circumferential trabeculotomy, are promising and at least equivalent to previous results for ab externo trabeculotomy for the treatment of PCG and JOAG. All eyes in the study were considered a clinical success. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. Aerodynamic Load Measurements and Opening Characteristics of Automatic Leading Edge Slats on a 45 deg Sweptback Wing at Transonic Speeds

    NASA Technical Reports Server (NTRS)

    Arabian, Donald D.; Runckel, Jack F.; Reid, Charles F, Jr.

    1961-01-01

    Measurements of the normal force and chord force were made on the slats of a sting-mounted wing-fuselage model through a Mach number range of 0.60 to 1.03 and at angles of attack from 0 to 20 deg at subsonic speeds and from 0 to 8 deg at Mach number 1.03. The 20-percent-chord tapered leading-edge slats extended from 25 to 95 percent of the semispan and consisted of five segments. The model wing had 45 deg sweep, an aspect ratio of 3.56, a taper ratio of 0.3, and NACA 64(06)AO07 airfoil sections. Slat forces and moments were determined for the slats in the almost-closed and open positions for spanwise extents of 35 to 95 percent and 46 to 95 percent of the semispan. The results of the investigation showed little change in the slat maximum force and moment coefficients with Mach number. The coefficients for the open and almost-closed slat positions had similar variations with angle of attack. The loads on the individual slat segments were found to increase toward the tip for moderate angles of attack and decrease toward the tip for high angles of attack. An analysis of the opening and closing characteristics of aerodynamically operated slats opening on a circular-arc path is included.

  2. A mechanical analysis of conduit arteries accounting for longitudinal residual strains.

    PubMed

    Wang, Ruoya; Gleason, Rudolph L

    2010-04-01

    Identification of an appropriate stress-free reference configuration is critically important in providing a reasonable prediction of the intramural stress distribution when performing biomechanical analyses on arteries. The stress-free state is commonly approximated as a radially cut ring that typically opens into a nearly circular sector, relieving much of the circumferential residual strains that exist in the traction-free configuration. An opening angle is often used to characterize this sector. In this study, we first present experimental results showing significant residual deformations in the longitudinal direction of two commonly studied arteries in the pig: the common carotid artery and the left anterior descending coronary artery. We concluded that a radially cut ring cannot completely describe the stress-free state of the arteries. Instead, we propose the use of a longitudinal opening angle, in conjunction with the traditional circumferential opening angle, to experimentally quantify the stress-free state of an artery. Secondly, we propose a new kinematic model to account for the addition of longitudinal residual strains through employing the longitudinal opening angle and performed a stress analysis. We found that with the inclusion of longitudinal residual strains in the stress analysis, the predicted circumferential stress gradient was decreased by 3-fold and the predicted longitudinal stress gradient was increased by 5.7-fold. Thus, inclusion of longitudinal residual strains has a significant effect on the predicted stress distribution in arteries.

  3. The effect of internal fixation lamp on anterior chamber angle width measured by anterior segment optical coherence tomography.

    PubMed

    Nakamine, Sakari; Sakai, Hiroshi; Arakaki, Yoshikuni; Yonahara, Michiko; Kaiya, Tadayoshi

    2018-01-01

    To study the effect of the internal fixation lamp on anterior chamber width measured by anterior segment optical coherence tomography. In a prospective cross sectional observational study, consecutive 22 right eyes of 22 patients (4 men and 18 women) with suspected primary angle closure underwent swept source domain anterior segment optical coherence tomography (AS-OCT), (CASIA SS-1000, Tomey, Nagoya, Japan). Anterior chamber parameters of angle opening distance (AOD), trabecular-iris angle (TIA), angle recess area (ARA) at 500 or 750 µm from scleral spur and pupil diameter were measured by AS-OCT in a three-dimensional mode in 4 quadrants (superior, inferior, temporal and nasal) in dark room setting both with and without internal fixation lamp. Anterior segment parameters of AOD 500 in superior, inferior and temporal quadrants, AOD 750 at superior and nasal, TIA 500 at superior, and inferior and TIA 750 at superior and nasal, and ARA 500 or 750 at superior and inferior with internal fixation lamp were greater and the pupil diameter was significantly (all P < 0.05, paired t test) smaller than when measured without fixation lamp. Internal fixation lamp of the anterior segment OCT makes the pupil constrict and angle wider. When using AS-OCT with usual setting with internal fixation lamp on with eyes in which the anterior chamber angle is narrow but open, it is recommended that the internal fixation lamp be turned off to ensure a clear indication as to whether the angle is open or closed in the dark.

  4. [Effects of nootropic agents on visual functions and lacrimal antioxidative activity in patients with primary open-angle glaucoma].

    PubMed

    Davydova, N G; Kuznetsova, T P; Borisova, S A; Abdulkadyrova, M Zh

    2006-01-01

    The paper presents the results of an investigation of the effect of the nootropic agents pantogam and nooclerine on visual functions in patients with primary open-angle glaucoma. These agents have been found to have a beneficial effect on the functional activity of the retina and optic nerve, light sensitivity, hemo- and hydrodynamics of the eye.

  5. Exclusion of chromosome 1q21-q31 from linkage to three pedigrees affected by the pigment-dispersion syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paglinauan, C.; Haines, J.L.; Del Bono, E.A.

    1995-05-01

    The pigment-dispersion syndrome is a form of open-angle glaucoma that usually affects individuals in the first 3 decades of life. In addition to the typical optic-nerve degeneration seen in all types of glaucoma, the pigment-dispersion syndrome is characterized by distinctive clinical features including the deposition of pigment granules from the iris epithelium on a variety of ocular structures including the trabecular meshwork. Frequently this disorder affects young myopic individuals. In the early stages of the disease, affected individuals may have clinical evidence of dispersed pigment without an associated elevation of intraocular pressure and optic-nerve degeneration. However, as the disease processmore » progresses, many affected individuals ({approximately}50%) will develop elevated intraocular pressure and degeneration of the optic nerve, causing a permanent loss of sight. The pigment-dispersion syndrome shares several clinical features with the form of autosomal dominant juvenile open-angle glaucoma that recently has been mapped to the 1q21-q31 region of chromosome 1. Our results indicate that the pigment-dispersion syndrome, a form of glaucoma that may also affect the juvenile population, is genetically unrelated to the autosomal dominant form of juvenile glaucoma caused by a defect in a gene located in the 1q21-q31 region of chromosome 1. 15 refs., 2 figs., 1 tab.« less

  6. Structural and functional brain changes in early- and mid-stage primary open-angle glaucoma using voxel-based morphometry and functional magnetic resonance imaging.

    PubMed

    Jiang, Ming-Ming; Zhou, Qing; Liu, Xiao-Yong; Shi, Chang-Zheng; Chen, Jian; Huang, Xiang-He

    2017-03-01

    To investigate structural and functional brain changes in patients with primary open-angle glaucoma (POAG) by using voxel-based morphometry based on diffeomorphic anatomical registration through exponentiated Lie algebra (VBM-DARTEL) and blood oxygenation level dependent functional magnetic resonance imaging (BOLD-fMRI), respectively.Thirteen patients diagnosed with POAG and 13 age- and sex-matched healthy controls were enrolled in the study. For each participant, high-resolution structural brain imaging and blood flow imaging were acquired on a 3.0-Tesla magnetic resonance imaging (MRI) scanner. Structural and functional changes between the POAG and control groups were analyzed. An analysis was carried out to identify correlations between structural and functional changes acquired in the previous analysis and the retinal nerve fiber layer (RNFL).Patients in the POAG group showed a significant (P < 0.001) volume increase in the midbrain, left brainstem, frontal gyrus, cerebellar vermis, left inferior parietal lobule, caudate nucleus, thalamus, precuneus, and Brodmann areas 7, 18, and 46. Moreover, significant (P < 0.001) BOLD signal changes were observed in the right supramarginal gyrus, frontal gyrus, superior frontal gyrus, left inferior parietal lobule, left cuneus, and left midcingulate area; many of these regions had high correlations with the RNFL.Patients with POAG undergo widespread and complex changes in cortical brain structure and blood flow. (ClinicalTrials.gov number: NCT02570867).

  7. Pathophysiology of primary open-angle glaucoma from a neuroinflammatory and neurotoxicity perspective: a review of the literature.

    PubMed

    Evangelho, Karine; Mogilevskaya, Maria; Losada-Barragan, Monica; Vargas-Sanchez, Jeinny Karina

    2017-12-30

    Glaucoma is the leading cause of blindness in humans, affecting 2% of the population. This disorder can be classified into various types including primary, secondary, glaucoma with angle closure and with open angle. The prevalence of distinct types of glaucoma differs for each particular region of the world. One of the most common types of this disease is primary open-angle glaucoma (POAG), which is a complex inherited disorder characterized by progressive retinal ganglion cell death, optic nerve head excavation and visual field loss. Nowadays, POAG is considered an optic neuropathy, while intraocular pressure is proposed to play a fundamental role in its pathophysiology and especially in optic disk damage. However, the exact mechanism of optic nerve head damage remains a topic of debate. This literature review aims to bring together the information on the pathophysiology of primary open-angle glaucoma, particularly focusing on neuroinflammatory mechanisms leading to the death of the retinal ganglion cell. A literature search was done on PubMed using key words including primary open-angle glaucoma, retinal ganglion cells, Müller cells, glutamate, glial cells, ischemia, hypoxia, exitotoxicity, neuroinflammation, axotomy and neurotrophic factors. The literature was reviewed to collect the information published about the pathophysiologic mechanisms of RGC death in the POAG, from a neuroinflammatory and neurotoxicity perspective. Proposed mechanisms for glaucomatous damage are a result of pressure in RGC followed by ischemia, hypoxia of the ONH, and consequently death due to glutamate-induced excitotoxicity, deprivation of energy and oxygen, increase in levels of inflammatory mediators and alteration of trophic factors flow. These events lead to blockage of anterograde and retrograde axonal transport with ensuing axotomy and eventually blindness. The damage to ganglion cells and eventually glaucomatous injury can occur via various mechanisms including baric trauma, ischemia and impact of metabolic toxins, which triggers an inflammatory process and secondary degeneration in the ONH.

  8. The relationship between the fistula tract and the facial nerve in type II first branchial cleft anomalies.

    PubMed

    Ertas, Burak; Gunaydin, Rıza Onder; Unal, Omer Faruk

    2015-04-01

    To share our experience involving seven patients with type II first branchial cleft anomalies (hereafter, type II anomalies), to determine whether the location of the external fistula openings of the anomalies are associated with the location of the facial nerve tract, and elucidate the relationship between the location of the fistula opening and the facial nerve. The medical records of seven patients who underwent surgery from 2005 to 2013 for type II anomalies were retrospectively examined. The relationship between the fistula opening and the facial nerve was evaluated in each patient with respect to whether the fistula opening was superior or inferior to the mandibular angle. All patients underwent partial parotidectomy, facial nerve exposure, and total excision of the mass together with connection of a small cuff of the external auditory canal skin to the fistula tract. The fistula tracts were located medially to the facial nerve in two patients, and both fistulae had openings inferior to the mandibular angle. The fistula tracts were located laterally to the facial nerve in the remaining five patients: one patient had no external opening, one had an opening inferior to the mandibular angle, and the remaining three had openings superior to the mandibular angle. Because type II anomalies are rare, their diagnosis is difficult. Surgery of such lesions is challenging and associated with a high risk due to their proximity to the facial nerve. We believe that the location of the fistula opening may help to identify the relationship between the anomalous lesion and facial nerve. Studies involving larger series of cases are needed to confirm our hypothesis; however, because of the rarity of this specific anomaly, it will not be easy to compile a large number of cases. We believe that our study will encourage further investigation on this subject. Copyright © 2014. Published by Elsevier Ireland Ltd.

  9. Comparison of Dimensional Accuracy between Open-Tray and Closed-Tray Implant Impression Technique in 15° Angled Implants

    PubMed Central

    Balouch, F; Jalalian, E; Nikkheslat, M; Ghavamian, R; Toopchi, Sh; Jallalian, F; Jalalian, S

    2013-01-01

    Statement of Problem: Various impression techniques have different effects on the accuracy of final cast dimensions. Meanwhile; there are some controversies about the best technique. Purpose: This study was performed to compare two kinds of implant impression methods (open tray and closed tray) on 15 degree angled implants. Materials and Method: In this experimental study, a steel model with 8 cm in diameter and 3 cm in height were produced with 3 holes devised inside to stabilize 3 implants. The central implant was straight and the other two implants were 15° angled. The two angled implants had 5 cm distance from each other and 3.5 cm from the central implant. Dental stone, high strength (type IV) was used for the main casts. Impression trays were filled with poly ether, and then the two impression techniques (open tray and closed tray) were compared. To evaluate positions of the implants, each cast was analyzed by CMM device in 3 dimensions (x,y,z). Differences in the measurements obtained from final casts and laboratory model were analyzed using t-Test. Results: The obtained results indicated that closed tray impression technique was significantly different in dimensional accuracy when compared with open tray method. Dimensional changes were 129 ± 37μ and 143.5 ± 43.67μ in closed tray and open tray, while coefficient of variation in closed- tray and open tray were reported to be 27.2% and 30.4%, respectively. Conclusion: Closed impression technique had less dimensional changes in comparison with open tray method, so this study suggests that closed tray impression technique is more accurate. PMID:24724130

  10. Tectonics of the Red Sea region reassessed

    NASA Astrophysics Data System (ADS)

    Ghebreab, Woldai

    1998-11-01

    The brittle upper level of the continental crust had been rifted with or without ocean opening many times in many places during the geological past and the process is still happening. Since the advent of plate tectonic theory in the early 1960s, the formation of such rifts has been viewed in the context of plate tectonic processes that caused the repeated dispersal of supercontinents. Several researchers focused on the mechanisms of formation of continental rifts because some rifts, like the Red Sea and Gulf of Aden, are precursors to ocean basins and many hydrocarbons yet to be located which are either directly or indirectly related to rift structures. The East African Rift System and the Red Sea-Gulf of Aden young oceans have been considered as prime examples of the early stage of continental separation that has long been a testing ground for classical hypotheses of continental drift. The Red Sea separates the once contiguous Neoproterozoic Arabian-Nubian Shields and started opening about 25 Ma ago. Geophysics and geochronology of dredged basaltic rocks indicate that sea-floor spreading began at only about 4-5 Ma. Numerous multidisciplinary investigations have been carried out in this region. However, several questions remain unresolved. Examples pertain to the nature of the crust that underlies the shelves, the extent of the ocean floor, the interplay between sea-floor spreading, crustal extension and plutonic activity and mechanisms of rifting. Several mechanisms of rifting have been proposed for the formation of the Red Sea. Examples include extension by prolonged steep normal faulting (horst-graben terrain), early diffuse ductile extension followed by brittle deformation, low-angle lithospheric simple shear, low-angle shear and magmatic expansion, lithospheric thinning by faulting and dike injection, northeastward migration of asymmetric rifting over a fixed mantle plume and the formation of pull-apart basin(s) by transtension. The major differences between the various models center on the relative timing of updoming, rifting and magmatism and whether the rifting was active and driven by a mantle plume or passive and due to lateral extension of the lithosphere leading to reactive effects in the mantle. New geological field data from the western margin of the Southern Red Sea in Eritrea reveal two main stages of NE-SW extension history. The first semi-brittle stage (⩾30 Ma) was dominantly characterized by top-to-east low-angle detachments. The second brittle stage of extension (since ˜22 Ma) occurred on a new system of dominantly down-to-southwest planar normal faults and dikes with NW-SE strikes. The earlier semi-brittle stage of extension corresponds to the predicted low-angle simple shear zone through the lithosphere and the later gives some support to the models that invoke graben-horst formation along steep normal faults that ultimately soled out to detachments at intermediate crustal level or merge with the Moho.

  11. Holographic Jet Shapes and their Evolution in Strongly Coupled Plasma

    NASA Astrophysics Data System (ADS)

    Brewer, Jasmine; Rajagopal, Krishna; Sadofyev, Andrey; van der Schee, Wilke

    2017-11-01

    Recently our group analyzed how the probability distribution for the jet opening angle is modified in an ensemble of jets that has propagated through an expanding cooling droplet of plasma [K. Rajagopal, A. V. Sadofyev, W. van der Schee, Phys. Rev. Lett. 116 (2016) 211603]. Each jet in the ensemble is represented holographically by a string in the dual 4+1- dimensional gravitational theory with the distribution of initial energies and opening angles in the ensemble given by perturbative QCD. In [K. Rajagopal, A. V. Sadofyev, W. van der Schee, Phys. Rev. Lett. 116 (2016) 211603], the full string dynamics were approximated by assuming that the string moves at the speed of light. We are now able to analyze the full string dynamics for a range of possible initial conditions, giving us access to the dynamics of holographic jets just after their creation. The nullification timescale and the features of the string when it has nullified are all results of the string evolution. This emboldens us to analyze the full jet shape modification, rather than just the opening angle modification of each jet in the ensemble as in [K. Rajagopal, A. V. Sadofyev, W. van der Schee, Phys. Rev. Lett. 116 (2016) 211603]. We find the result that the jet shape scales with the opening angle at any particular energy. We construct an ensemble of dijets with energies and energy asymmetry distributions taken from events in proton-proton collisions, opening angle distribution as in [K. Rajagopal, A. V. Sadofyev, W. van der Schee, Phys. Rev. Lett. 116 (2016) 211603], and jet shape taken from proton-proton collisions and scaled according to our result. We study how these observables are modified after we send the ensemble of dijets through the strongly-coupled plasma.

  12. Effectiveness of early lens extraction for the treatment of primary angle-closure glaucoma (EAGLE): a randomised controlled trial.

    PubMed

    Azuara-Blanco, Augusto; Burr, Jennifer; Ramsay, Craig; Cooper, David; Foster, Paul J; Friedman, David S; Scotland, Graham; Javanbakht, Mehdi; Cochrane, Claire; Norrie, John

    2016-10-01

    Primary angle-closure glaucoma is a leading cause of irreversible blindness worldwide. In early-stage disease, intraocular pressure is raised without visual loss. Because the crystalline lens has a major mechanistic role, lens extraction might be a useful initial treatment. From Jan 8, 2009, to Dec 28, 2011, we enrolled patients from 30 hospital eye services in five countries. Randomisation was done by a web-based application. Patients were assigned to undergo clear-lens extraction or receive standard care with laser peripheral iridotomy and topical medical treatment. Eligible patients were aged 50 years or older, did not have cataracts, and had newly diagnosed primary angle closure with intraocular pressure 30 mm Hg or greater or primary angle-closure glaucoma. The co-primary endpoints were patient-reported health status, intraocular pressure, and incremental cost-effectiveness ratio per quality-adjusted life-year gained 36 months after treatment. Analysis was by intention to treat. This study is registered, number ISRCTN44464607. Of 419 participants enrolled, 155 had primary angle closure and 263 primary angle-closure glaucoma. 208 were assigned to clear-lens extraction and 211 to standard care, of whom 351 (84%) had complete data on health status and 366 (87%) on intraocular pressure. The mean health status score (0·87 [SD 0·12]), assessed with the European Quality of Life-5 Dimensions questionnaire, was 0·052 higher (95% CI 0·015-0·088, p=0·005) and mean intraocular pressure (16·6 [SD 3·5] mm Hg) 1·18 mm Hg lower (95% CI -1·99 to -0·38, p=0·004) after clear-lens extraction than after standard care. The incremental cost-effectiveness ratio was £14 284 for initial lens extraction versus standard care. Irreversible loss of vision occurred in one participant who underwent clear-lens extraction and three who received standard care. No patients had serious adverse events. Clear-lens extraction showed greater efficacy and was more cost-effective than laser peripheral iridotomy, and should be considered as an option for first-line treatment. Medical Research Council. Copyright © 2016 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.

  13. Using Digital Technology to See Angles from Different Angles. Part 2: Openings and Turns

    ERIC Educational Resources Information Center

    Host, Erin; Baynham, Emily; McMaster, Heather

    2015-01-01

    Ever wondered how to use technology to teach angles? This article follows on from an earlier article published last year, providing a range of ideas for integrating technology and concrete materials with the teaching of angle concepts. The authors also provide a comprehensive list of free online games and learning objects that can be used to teach…

  14. The Prevalence of Age-Related Eye Diseases and Visual Impairment in Aging: Current Estimates

    PubMed Central

    Klein, Ronald; Klein, Barbara E. K.

    2013-01-01

    Purpose. To examine prevalence of five age-related eye conditions (age-related cataract, AMD, open-angle glaucoma, diabetic retinopathy [DR], and visual impairment) in the United States. Methods. Review of published scientific articles and unpublished research findings. Results. Cataract, AMD, open-angle glaucoma, DR, and visual impairment prevalences are high in four different studies of these conditions, especially in people over 75 years of age. There are disparities among racial/ethnic groups with higher age-specific prevalence of DR, open-angle glaucoma, and visual impairment in Hispanics and blacks compared with whites, higher prevalence of age-related cataract in whites compared with blacks, and higher prevalence of late AMD in whites compared with Hispanics and blacks. The estimates are based on old data and do not reflect recent changes in the distribution of age and race/ethnicity in the United States population. There are no epidemiologic estimates of prevalence for many visually-impairing conditions. Conclusions. Ongoing prevalence surveys designed to provide reliable estimates of visual impairment, AMD, age-related cataract, open-angle glaucoma, and DR are needed. It is important to collect objective data on these and other conditions that affect vision and quality of life in order to plan for health care needs and identify areas for further research. PMID:24335069

  15. Long Term Results of Visual Field Progression Analysis in Open Angle Glaucoma Patients Under Treatment.

    PubMed

    Kocatürk, Tolga; Bekmez, Sinan; Katrancı, Merve; Çakmak, Harun; Dayanır, Volkan

    2015-01-01

    To evaluate visual field progression with trend and event analysis in open angle glaucoma patients under treatment. Fifteen year follow-up results of 408 eyes of 217 glaucoma patients who were followed at Adnan Menderes University, Department of Ophthalmology between 1998 and 2013 were analyzed retrospectively. Visual field data were collected for Mean Deviation (MD), Visual Field Index (VFI), and event occurrence. There were 146 primary open-angle glaucoma (POAG), 123 pseudoexfoliative glaucoma (XFG) and 139 normal tension glaucoma (NTG) eyes. MD showed significant change in all diagnostic groups (p<0.001). The difference of VFI between first and last examinations were significantly different in POAG (p<0.001), and XFG (p<0.003) but not in NTG. VFI progression rates were -0.3, -0.43, and -0.2 % loss/year in treated POAG, XFG, and NTG, respectively. The number of empty triangles were statistically different between POAG-NTG (p=0.001), and XFG-NTG (p=0.002) groups. The number of half-filled (p=0.002), and full-filled (p=0.010) triangles were significantly different between XFG-NTG groups. Functional long-term follow-up of glaucoma patients can be monitored with visual field indices. We herein report our fifteen year follow-up results in open angle glaucoma.

  16. Economic impact of primary open-angle glaucoma in Australia.

    PubMed

    Dirani, Mohamed; Crowston, Jonathan G; Taylor, Penny S; Moore, Peter T; Rogers, Sophie; Pezzullo, M Lynne; Keeffe, Jill E; Taylor, Hugh R

    2011-01-01

    Glaucoma is the World's leading cause of irreversible blindness, and poses serious public health and economic concerns.   Review. Published randomized trials and population-based studies since 1985. We report the economic impact of primary open-angle glaucoma and model the effect of changes in detection rates and management strategies. The cost-effectiveness of different interventions to prevent vision loss from primary open-angle glaucoma was measured in terms of financial cost (Australian dollars) and disability-adjusted life years. The prevalence of glaucoma in Australia is expected to increase from 208 000 in 2005 to 379 000 in 2025 because of the aging population. Health system costs over the same time period are estimated to increase from $AU355 million to $AU784 million. Total costs (health system costs, indirect costs and costs of loss of well-being) will increase from $AU1.9 billion to $AU4.3 billion in Australia. Primary open-angle glaucoma poses a significant economic burden, which will increase substantially by 2025. This dynamic model provides a valuable tool for ongoing policy formulation and determining the economic impact of interventions to better prevent visual impairment and blindness from glaucoma. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  17. Investigation of Blade Angle of an Open Cross-Flow Runner

    NASA Astrophysics Data System (ADS)

    Katayama, Yusuke; Iio, Shouichiro; Veerapun, Salisa; Uchiyama, Tomomi

    2015-04-01

    The aim of this study was to develop a nano-hydraulic turbine utilizing drop structure in irrigation channels or industrial waterways. This study was focused on an open-type cross-flow turbine without any attached equipment for cost reduction and easy maintenance. In this study, the authors used an artificial indoor waterfall as lab model. Test runner which is a simple structure of 20 circular arc-shaped blades sandwiched by two circular plates was used The optimum inlet blade angle and the relationship between the power performance and the flow rate approaching theoretically and experimentally were investigated. As a result, the optimum inlet blade angle due to the flow rate was changed. Additionally, allocation rate of power output in 1st stage and 2nd stage is changed by the blade inlet angle.

  18. [Perspectives in glaucoma surgery].

    PubMed

    Dietlein, T S

    2002-02-01

    Trabeculectomy is still considered to be the gold standard in the surgical treatment of the open-angle glaucomas. The additional application of local antimetabolites has reduced the rate of early filtering bled fibrosis, but increased the rate of essential late-postoperative complications. Growth factor inhibition and photodynamic therapy may be an alternative local treatment to enhance the results in filtering surgery. Non-penetrating glaucoma surgery and ab-interno trabecular surgery have several conceptual advantages, e.g. the lack of overfiltration or the untouched conjunctiva in the ab-interno approach. Clinical studies of these and other new procedures including antiglaucomatous retinectomy and subchoroidal shunt systems are currently performed in order to evaluate their potential and limits in the clinical management of glaucoma.

  19. Differences in iris thickness among African Americans, Caucasian Americans, Hispanic Americans, Chinese Americans, and Filipino-Americans.

    PubMed

    Lee, Roland Y; Huang, Guofu; Porco, Travis C; Chen, Yi-Chun; He, Mingguang; Lin, Shan C

    2013-12-01

    To evaluate the capability of iris thickness parameters to explain the difference in primary angle-closure glaucoma prevalence among the different racial groups. In this prospective study, 436 patients with open and narrow angles that met inclusion criteria were consecutively recruited from the UCSF general ophthalmology and glaucoma clinics to receive anterior segment optical coherence tomography imaging under standardized dark conditions. Images from 11 patients were removed due to poor visibility of the scleral spurs and the remaining images were analyzed using the Zhongshan Angle Assessment Program to assess the following measurements for the nasal and temporal angle of the anterior chamber: iris thickness at 750 and 2000 μm from the scleral spurs and the maximum iris thickness at middle one third of the iris. Iris thickness parameters were compared among and within the following 5 different racial groups: African Americans, Caucasian Americans, Hispanic Americans, Chinese Americans, and Filipino-Americans. In comparing iris parameters among the open-angle racial groups, significant differences were found for nasal iris thickness at 750 and 2000 μm from the scleral spurs in which Chinese Americans displayed the highest mean value (P=0.01, P<0.0001). Among the narrow-angle racial groups, significant difference was found for nasal iris thickness at 2000 μm from the scleral in which Chinese Americans showed the highest mean value (P<0.0001). Significant difference was also found for temporal maximum iris thickness at middle one third of the iris in which African Americans exhibited the highest mean value (P=0.021). Iris thickness was modeled as a function of angle status using linear mixed-effects regression, adjusting for age, sex, pupil diameter, spherical equivalent, ethnicity, and the use of both eyes in patients. The iris thickness difference between the narrow-angle and open-angle groups was significant (P=0.0007). Racial groups that historically showed higher prevalence of primary angle-closure glaucoma possess thicker irides.

  20. Pilot Study of the Effects of Ambient Light Level Variation on Spectral Domain Anterior Segment OCT-Derived Angle Metrics in Caucasians versus Asians.

    PubMed

    Dastiridou, Anna; Marion, Kenneth; Niemeyer, Moritz; Francis, Brian; Sadda, Srinivas; Chopra, Vikas

    2018-04-11

    To investigate the effects of ambient light level variation on spectral domain anterior segment optical coherence tomography (SD-ΟCT)-derived anterior chamber angle metrics in Caucasians versus Asians. Caucasian (n = 24) and Asian participants of Chinese ancestry (n = 24) with open angles on gonioscopy had one eye imaged twice at five strictly controlled, ambient light levels. Ethnicity was self-reported. Light levels were strictly controlled using a light meter at 1.0, 0.75, 0.5, 0.25, and 0 foot candle illumination levels. SD-OCT 5-line raster scans at the inferior 270° irido-corneal angle were measured by two trained, masked graders from the Doheny Image Reading Center using customized Image-J software. Schwalbe's line-angle opening distance (SL-AOD) and SL-trabecular iris space area (SL-TISA) in different light meter readings (LMRs) between the two groups were compared. Baseline light SL-AOD and SL-TISA measured 0.464 ± 0.115mm/0.351 ± 0.110mm 2 and 0.344 ± 0.118mm/0.257 ± 0.092mm 2 , respectively, in the Caucasian and the Asian group. SL-AOD and SL-TISA in each LMR were significantly larger in the Caucasian group compared to the Asian group (p < 0.05). Despite this difference in angle size between the groups, there were no statistically significant differences in the degree of change in angle parameters from light to dark (% changes in SL-AOD or SL-TISA between the two groups were statistically similar with all p-values >0.3). SL-based angle dimensions using SD-OCT are sensitive to changes in ambient illumination in participants with Caucasian and Asian ancestry. Although Caucasian eyes had larger baseline angle opening under bright light conditions, the light-to-dark change in angle dimensions was similar in the two groups.

  1. A comparison of gait biomechanics of flip-flops, sandals, barefoot and shoes.

    PubMed

    Zhang, Xiuli; Paquette, Max R; Zhang, Songning

    2013-11-06

    Flip-flops and sandals are popular choices of footwear due to their convenience. However, the effects of these types of footwear on lower extremity biomechanics are still poorly understood. Therefore, the objective of this study was to investigate differences in ground reaction force (GRF), center of pressure (COP) and lower extremity joint kinematic and kinetic variables during level-walking in flip-flops, sandals and barefoot compared to running shoes. Ten healthy males performed five walking trials in the four footwear conditions at 1.3 m/s. Three-dimensional GRF and kinematic data were simultaneously collected. A smaller loading rate of the 1st peak vertical GRF and peak propulsive GRF and greater peak dorsiflexion moment in early stance were found in shoes compared to barefoot, flip-flops and sandals. Barefoot walking yielded greater mediolateral COP displacement, flatter foot contact angle, increased ankle plantarflexion contact angle, and smaller knee flexion contact angle and range of motion compared to all other footwear. The results from this study indicate that barefoot, flip-flops and sandals produced different peak GRF variables and ankle moment compared to shoes while all footwear yield different COP and ankle and knee kinematics compared to barefoot. The findings may be helpful to researchers and clinicians in understanding lower extremity mechanics of open-toe footwear.

  2. Novel Automated Approach to Predict the Outcome of Laser Peripheral Iridotomy for Primary Angle Closure Suspect Eyes Using Anterior Segment Optical Coherence Tomography.

    PubMed

    Koh, Victor; Swamidoss, Issac Niwas; Aquino, Maria Cecilia D; Chew, Paul T; Sng, Chelvin

    2018-04-27

    Develop an algorithm to predict the success of laser peripheral iridotomy (LPI) in primary angle closure suspect (PACS), using pre-treatment anterior segment optical coherence tomography (ASOCT) scans. A total of 116 eyes with PACS underwent LPI and time-domain ASOCT scans (temporal and nasal cuts) were performed before and 1 month after LPI. All the post-treatment scans were classified to one of the following categories: (a) both angles open, (b) one of two angles open and (c) both angles closed. After LPI, success is defined as one or more angles changed from close to open. In this proposed method, the pre and post-LPI ASOCT scans were registered at the corresponding angles based on similarities between the respective local descriptor features and random sample consensus technique was used to identify the largest consensus set of correspondences between the pre and post-LPI ASOCT scans. Subsequently, features such as correlation co-efficient (CC) and structural similarity index (SSIM) were extracted and correlated with the success of LPI. We included 116 eyes and 91 (78.44%) eyes fulfilled the criteria for success after LPI. Using the CC and SSIM index scores from this training set of ASOCT images, our algorithm showed that the success of LPI in eyes with narrow angles can be predicted with 89.7% accuracy, specificity of 95.2% and sensitivity of 36.4% based on pre-LPI ASOCT scans only. Using pre-LPI ASOCT scans, our proposed algorithm showed good accuracy in predicting the success of LPI for PACS eyes. This fully-automated algorithm could aid decision making in offering LPI as a prophylactic treatment for PACS.

  3. Passive rejection of heat from an isotope heat source through an open door

    NASA Technical Reports Server (NTRS)

    Burns, R. K.

    1971-01-01

    The isotope heat-source design for a Brayton power system includes a door in the thermal insulation through which the heat can be passively rejected to space when the power system is not operating. The results of an analysis to predict the heat-source surface temperature and the heat-source heat-exchanger temperature during passive heat rejection as a function of insulation door opening angle are presented. They show that for a door opening angle greater than 20 deg, the temperatures are less than the steady-state temperatures during power system operation.

  4. Changes in anterior segment morphology in response to illumination and after laser iridotomy in Asian eyes: an anterior segment OCT study

    PubMed Central

    See, Jovina L S; Chew, Paul T K; Smith, Scott D; Nolan, Winifred P; Chan, Yiong‐Huak; Huang, David; Zheng, Ce; Foster, Paul J; Aung, Tin; Friedman, David S

    2007-01-01

    Aim Using the anterior segment optical coherence tomography (AS‐OCT) to quantify changes in anterior segment morphology going from light to dark and following laser iridotomy (LI). Methods Prospective observational study. 17 consecutive subjects without peripheral anterior synechiae undergoing LI were evaluated using gonioscopy and AS‐OCT. Angle configuration including angle opening distance (AOD) at 500 microns anterior to the scleral spur, AOD500, trabecular‐iris space area up to 750 microns from the scleral spur, TISA750 and the increase in angle opening going from dark to light conditions was determined. Results Both mean AOD500 and TISA750 increased nearly threefold going from dark to light. Both also significantly increased following LI (p<0.001) as did gonioscopic grading of the angle in all quadrants (p<0.001, McNemar's test). Angles were more than twice as wide on average in the dark after LI than before LI (p<0.05). Both the mean absolute change and the mean proportionate change in AOD500 and TISA750 when going from light to dark were greater after LI than before (p<0.05). Conclusion Increased illumination as well as LI resulted in significant widening of the anterior chamber angle. AS‐OCT (which does not require a water bath and can be performed with the patient at the slit lamp) identified similar magnitude changes as those previously reported using ultrasound biomicroscopy (UBM). Furthermore, the angle appears to open more both in absolute terms and and proportionate terms in response to illumination after LI. PMID:17504852

  5. Baseline Risk Factors that Predict the Development of Open-angle Glaucoma in a Population: The Los Angeles Latino Eye Study

    PubMed Central

    Jiang, Xuejuan; Varma, Rohit; Wu, Shuang; Torres, Mina; Azen, Stanley P; Francis, Brian A.; Chopra, Vikas; Nguyen, Betsy Bao-Thu

    2012-01-01

    Objective To determine which baseline socio-demographic, lifestyle, anthropometric, clinical, and ocular risk factors predict the development of open-angle glaucoma (OAG) in an adult population. Design A population-based, prospective cohort study. Participants A total of 3,772 self-identified Latinos aged 40 years and older from Los Angeles, California who were free of OAG at baseline. Methods Participants from the Los Angeles Latino Eye Study had standardized study visits at baseline and 4-year follow-up with structured interviews and a comprehensive ophthalmologic examination. OAG was defined as the presence of an open angle and a glaucomatous visual field abnormality and/or evidence of glaucomatous optic nerve damage in at least one eye. Multivariate logistic regression with stepwise selection was performed to determine which potential baseline risk factors independently predict the development of OAG. Main Outcome Measure Odds ratios for various risk factors. Results Over the 4-year follow-up, 87 participants developed OAG. The baseline risk factors that predict the development of OAG include: older age (odds ratio [OR] per decade, 2.19; 95% confidence intervals [CI], 1.74-2.75; P<0.001), higher intraocular pressure (OR per mmHg, 1.18; 95% CI, 1.10-1.26; P<0.001), longer axial length (OR per mm, 1.48; 95% CI, 1.22-1.80; P<0.001), thinner central cornea (OR per 40 μm thinner, 1.30; 95% CI, 1.00-1.70; P=0.050) higher waist to hip ratio (OR per 0.05 higher, 1.21; 95% CI, 1.05-1.39; P=0.007) and lack of vision insurance (OR, 2.08; 95% CI, 1.26-3.41; P=0.004). Conclusions Despite a mean baseline IOP of 14 mmHg in Latinos, higher intraocular pressure is an important risk factor for developing OAG. Biometric measures suggestive of less structural support such as longer axial length and thin CCT were identified as important risk factors. Lack of health insurance reduces access to eye care and increases the burden of OAG by reducing the likelihood of early detection and treatment of OAG. PMID:22796305

  6. Linkage studies in primary open angle glaucoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Avramopoulos, D.; Grigoriadu, M.; Kitsos, G.

    1994-09-01

    Glaucoma is a leading cause of blindness worldwide. The majority of glaucoma is associated with an open, normal appearing anterior chamber angle and is termed primary open angle glaucoma (POAG, MIM 137760). It is characterized by elevated intraocular pressure and onset in middle age or later. A subset of POAG with juvenile onset has recently been linked to chromosome 1q in two families with autosomal dominant inheritance. Eleven pedigrees with autosomal dominant POG (non-juvenile-onset) have been identified in Epirus, Greece. In the present study DNA samples have been collected from 50 individuals from one large pedigree, including 12 affected individuals.more » Preliminary results of linkage analysis with chromosome 1 microsatellites using the computer program package LINKAGE Version 5.1 showed no linkage with the markers previously linked to juvenile-onset POAG. Further linkage analysis is being pursued, and the results will be presented.« less

  7. Visual Disability Among Juvenile Open-angle Glaucoma Patients.

    PubMed

    Gupta, Viney; Ganesan, Vaitheeswaran L; Kumar, Sandip; Chaurasia, Abadh K; Malhotra, Sumit; Gupta, Shikha

    2018-04-01

    Juvenile onset primary open-angle glaucoma (JOAG) unlike adult onset primary open-angle glaucoma presents with high intraocular pressure and diffuse visual field loss, which if left untreated leads to severe visual disability. The study aimed to evaluate the extent of visual disability among JOAG patients presenting to a tertiary eye care facility. Visual acuity and perimetry records of unrelated JOAG patients presenting to our Glaucoma facility were analyzed. Low vision and blindness was categorized by the WHO criteria and percentage impairment was calculated as per the guidelines provided by the American Medical Association (AMA). Fifty-two (15%) of the 348 JOAG patients were bilaterally blind at presentation and 32 (9%) had low vision according to WHO criteria. Ninety JOAG patients (26%) had a visual impairment of 75% or more. Visual disability at presentation among JOAG patients is high. This entails a huge economic burden, given their young age and associated social responsibilities.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, B; Wong, R; Lam, W

    Purpose: To develop a practical method for routine QA of the MLC of a Tomotherapy unit using ArcCheck. Methods: Two standard test plans were used in this study. One was a helical test, in which the central leaves No. 32 and 33 opened simultaneously for 277.8ms at projections centered at 0°, 120° and 240° gantry angles. The other test plan was a static test with the gantry angle set at 0°, 45°, 90° and 135° respectively and leaves No. 32 and 33 opened sequentially for total 20s which was further divided into eleven or ten segments at each beam angle.more » The ArcCheck was isocentrically set up and adjusted for couch sag. Movie files which took a snapshot exposure every 50ms were recorded. The start/stop time of leaf open was decided by the ramp-up/ramp-down of the detectors. Results: The percentage differences between measured and planned leaf open time were calculated to be within 0.5% in all the tests. In static test, if leaves are synchronized perfectly, the sum of the two detectors’ signals after normalization should equal one when the leaves are in transition. Our results showed mean values of 0.982, 0.983, 0.978 and 0.995 at static gantry angle 0°, 45°, 90° and 135° respectively. Conclusion: A method for estimating the Tomotherapy binary MLC leaf open time using ArcCheck is proposed and proved to be precise enough to verify the planned leaf open time as small as 277.8ms. This method also makes the observation and quantification of the synchronization of leaves possible.« less

  9. Foreland crustal structure of the New York recess, northeastern United States

    USGS Publications Warehouse

    Herman, G.C.; Monteverde, D.H.; Schlische, R.W.; Pitcher, D.M.

    1997-01-01

    A new structural model for the northeast part of the Central Appalachian foreland and fold-and-thrust belt is based on detailed field mapping, geophysical data, and balanced cross-section analysis. The model demonstrates that the region contains a multiply deformed, parautochthonous fold-and-thrust system of Paleozoic age. Our interpretations differ from previous ones in which the entire region north of the Newark basin was considered to be allochthonous. The new interpretation requires a substantial decrease in Paleozoic tectonic shortening northeastward from adjacent parts of the Central Appalachian foreland and illustrates the common occurrence of back-thrusting within the region. During early Paleozoic time northern New Jersey consisted of a Taconic orogenic foreland in which cover folds (F1) involved lower Paleozoic carbonate and flysch overlying Middle Proterozoic basement. F1 folds are open and upright in the foreland and more gently inclined to recumbent southeastward toward the trace of the Taconic allochthons. F1 structures were cut and transported by a fold-and-thrust system of the Allegheny orogeny. This thrust system mostly involves synthetic faults originating from a master decollement rooted in Proterozoic basement. Antithetic faults locally modify early synthetic overthrusts and S1 cleavage in lower Paleozoic cover and show out-of-sequence structural development. The synthetic parts of the regional thrust system are bounded in the northwestern foreland by blind antithetic faults interpreted from seismic-reflection data. This antithetic faulting probably represents Paleozoic reactivation of Late Proterozoic basement faults. Tectonic contraction in overlying cover occurred by wedge faulting where synthetic and antithetic components of the foreland fault system overlap. S2 cleavage in the Paleozoic cover stems from Alleghanian shortening and flattening and commonly occurs in the footwall of large overthrust sheets. Paleozoic structures in Proterozoic basement include fault blocks bounded by high-angle faults and low- to moderate-angle shear zones that locally produce overlying cover folds. Broad and open folds in basement probably reflect shear-zone displacement of subhorizontal foliation. Our cross-section interpretations require limited involvement of lower Paleozoic cover folds in the footwalls of major overthrust faults. Palinspastic restoration of F1 folds produces an arched passive-margin sequence. The tectonic contraction for the Valley and Ridge province and southeastern Pocono Plateau is about 25 km, and tectonic wedge angles are 8??-11??.

  10. Experimental assessment of theory for refraction of sound by a shear layer

    NASA Technical Reports Server (NTRS)

    Schlinker, R. H.; Amiet, R. K.

    1978-01-01

    The refraction angle and amplitude changes associated with sound transmission through a circular, open-jet shear layer were studied in a 0.91 m diameter open jet acoustic research tunnel. Free stream Mach number was varied from 0.1 to 0.4. Good agreement between refraction angle correction theory and experiment was obtained over the test Mach number, frequency and angle measurement range for all on-axis acoustic source locations. For off-axis source positions, good agreement was obtained at a source-to-shear layer separation distance greater than the jet radius. Measureable differences between theory and experiment occurred at a source-to-shear layer separation distance less than one jet radius. A shear layer turbulence scattering experiment was conducted at 90 deg to the open jet axis for the same free stream Mach numbers and axial source locations used in the refraction study. Significant discrete tone spectrum broadening and tone amplitude changes were observed at open jet Mach numbers above 0.2 and at acoustic source frequencies greater than 5 kHz. More severe turbulence scattering was observed for downstream source locations.

  11. Zero-stress states of human pulmonary arteries and veins.

    PubMed

    Huang, W; Yen, R T

    1998-09-01

    The zero-stress states of the pulmonary arteries and veins from order 3 to order 9 were determined in six normal human lungs within 15 h postmortem. The zero-stress state of each vessel was obtained by cutting the vessel transversely into a series of short rings, then cutting each ring radially, which caused the ring to spring open into a sector. Each sector was characterized by its opening angle. The mean opening angle varied between 92 and 163 degrees in the arterial tree and between 89 and 128 degrees in the venous tree. There was a tendency for opening angles to increase as the sizes of the arteries and veins increased. We computed the residual strains based on the experimental measurements and estimated the residual stresses according to Hooke's law. We found that the inner wall of a vessel at the state in which the internal pressure, external pressure, and longitudinal stress are all zero was under compression and the outer wall was in tension, and that the magnitude of compressive stress was greater than the magnitude of tensile stress.

  12. Comparative proteomic study in serum of patients with primary open-angle glaucoma and pseudoexfoliation glaucoma.

    PubMed

    González-Iglesias, Héctor; Álvarez, Lydia; García, Montserrat; Escribano, Julio; Rodríguez-Calvo, Pedro Pablo; Fernández-Vega, Luis; Coca-Prados, Miguel

    2014-02-26

    Alterations in the sera proteins between patients with Primary Open-Angle Glaucoma (POAG), Pseudoexfoliation Glaucoma (PEXG), and healthy controls were identified through a proven approach utilizing equalization of high-abundance serum proteins with ProteoMiner™, two-dimensional fluorescent difference gel electrophoresis (2D-DIGE), MALDI-TOF/TOF, and nanoLC-MS-MS. Quantitative immunoassays of the 17 most-differentially-altered proteins identified in this analysis confirmed that they were also over expressed in the intact serum of newly recruited glaucoma patients. Overall, this report identifies a panel of candidates for glaucoma biomarkers and supports their further validation in large population studies. Additionally, functional pathway analysis of these candidate proteins suggested that they are part of a network linked to regulating immune and inflammatory-related processes. The data have been deposited to the ProteomeXchange with identifier PXD000198. POAG and PEXG are major causes of age-related blindness in the world; however, treatment can be very effective if they are identified early on in the progression. Genetic linkage studies can only explain a limited number of cases, suggesting that these forms of glaucoma are multigenic in nature. Other important factors, such as modifier genes, epigenetic influences, environmental and dietary agents, and inflammatory and oxidative effects are also believed to affect the development of these diseases. The characterization of metabolic and/or proteins changes, for example in bodily fluids, before the clinical manifestation of glaucoma is of considerable relevance for its early diagnosis. In the present work, identification of over-expressed proteins in serum of glaucoma patients (POAG and PEXG) linked to immune and inflammatory processes supports the finding that changes in these pathways also manifest systemically in patients with these pathologies. This study provides a new basis to validate the identified proteins as biomarkers of glaucoma in a large-scale-multiplexed screening in sera. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Does hemipelvis structure and position influence acetabulum orientation?

    PubMed

    Musielak, Bartosz; Jóźwiak, Marek; Rychlik, Michał; Chen, Brian Po-Jung; Idzior, Maciej; Grzegorzewski, Andrzej

    2016-03-16

    Although acetabulum orientation is well established anatomically and radiographically, its relation to the innominate bone has rarely been addressed. If explored, it could open the discussion on patomechanisms of such complex disorders as femoroacetabular impingement (FAI). We therefore evaluated the influence of pelvic bone position and structure on acetabular spatial orientation. We describe this relation and its clinical implications. This retrospective study was based on computed tomography scanning of three-dimensional models of 31 consecutive male pelvises (62 acetabulums). All measurements were based on CT spatial reconstruction with the use of highly specialized software (Rhinoceros). Relations between acetabular orientation (inclination, tilt, anteversion angles) and pelvic structure were evaluated. The following parameters were evaluated to assess the pelvic structure: iliac opening angle, iliac tilt angle, interspinous distance (ISD), intertuberous distance (ITD), height of the pelvis (HP), and the ISD/ITD/HP ratio. The linear and nonlinear dependence of the acetabular angles and hemipelvic measurements were examined with Pearson's product - moment correlation and Spearman's rank correlation coefficient. Correlations different from 0 with p < 0.05 were considered statistically significant. Comparison of the axis position with pelvis structure with orientation in the horizontal plane revealed a significant positive correlation between the acetabular anteversion angle and the iliac opening angle (p = 0.041 and 0.008, respectively). In the frontal plane, there was a positive correlation between the acetabular inclination angle and the iliac tilt angle (p = 0.025 and 0.014, respectively) and the acetabular inclination angle and the ISD/ITD/HP ratio (both p = 0.048). There is a significant correlation of the hemipelvic structure and acetabular orientation under anatomic conditions, especially in the frontal and horizontal planes. In the anteroposterior view, the more tilted-down innominate bone causes a more caudally oriented acetabulum axis, whereas in the horizontal view this relation is reversed. This study may serve as a basis for the discussion on the role of the pelvis in common disorders of the hip.

  14. Association of Baseline Anterior Segment Parameters With the Development of Incident Gonioscopic Angle Closure.

    PubMed

    Nongpiur, Monisha E; Aboobakar, Inas F; Baskaran, Mani; Narayanaswamy, Arun; Sakata, Lisandro M; Wu, Renyi; Atalay, Eray; Friedman, David S; Aung, Tin

    2017-03-01

    Baseline anterior segment imaging parameters associated with incident gonioscopic angle closure, to our knowledge, are unknown. To identify baseline quantitative anterior segment optical coherence tomography parameters associated with the development of incident gonioscopic angle closure after 4 years among participants with gonioscopically open angles at baseline. Three hundred forty-two participants aged 50 years or older were recruited to participate in this prospective, community-based observational study. Participants underwent gonioscopy and anterior segment optical coherence tomography imaging at baseline and after 4 years. Custom image analysis software was used to quantify anterior chamber parameters from anterior segment optical coherence tomography images. Baseline anterior segment optical coherence tomography measurements among participants with gonioscopically open vs closed angles at follow-up. Of the 342 participants, 187 (55%) were women and 297 (87%) were Chinese. The response rate was 62.4%. Forty-nine participants (14.3%) developed gonioscopic angle closure after 4 years. The mean age (SD) at baseline of the 49 participants was 62.9 (8.0) years, 15 (30.6%) were men, and 43 (87.8%) were Chinese. These participants had a smaller baseline angle opening distance at 750 µm (AOD750) (0.15 mm; 95% CI, 0.12-0.18), trabecular iris surface area at 750 µm (0.07 mm2; 95% CI, 0.05-0.08), anterior chamber area (30 mm2; 95% CI, 2.27-3.74), and anterior chamber volume (24.32 mm2; 95% CI, 18.20-30.44) (all P < .001). Baseline iris curvature (-0.08; 95% CI, -0.12 to -0.04) and lens vault (LV) measurements (-0.29 mm; 95% CI, -0.37 to -0.21) were larger among these participants ( all P < .001). A model consisting of the LV and AOD750 measurements explained 38% of the variance in gonioscopic angle closure occurring at 4 years, with LV accounting for 28% of this variance. For every 0.1 mm increase in LV and 0.1 mm decrease in AOD750, the odds of developing gonioscopic angle closure was 1.29 (95% CI, 1.07-1.57) and 3.27 (95% CI, 1.87-5.69), respectively. In terms of per SD change in LV and AOD750, this translates to an odds ratio of 2.14 (95% CI, 2.48-12.34) and 5.53 (95% CI, 1.22-3.77), respectively. A baseline LV cut-off value of >0.56 mm had 64.6% sensitivity and 84.0% specificity for identifying participants who developed angle closure. These findings suggest that smaller AOD750 and larger LV measurements are associated with the development of incident gonioscopic angle closure after 4 years among participants with gonioscopically open angles at baseline.

  15. Early Clinical Features of Pseudoexfoliation Syndrome in Anterior Segment and Gonioscopy Examination.

    PubMed

    Gür Güngör, Sirel; Bayer, Atilla; Akman, Ahmet; Asena, Leyla

    2017-01-01

    To determine the early signs of pseudoexfoliation (PEX) in fellow eyes of cases with unilateral PEX. Fellow eyes of 34 cases with unilateral PEX were evaluated by slit-lamp and gonioscopy. Findings associated with PEX were recorded. Mean age was 67.8±8.1 years (range 55-86 years). Twenty-five patients (73.5%) had pigmentation in the inferior angle and 23 patients (67.6%) had Sampaolesi's line located on the inferior angle in fellow eyes. The other most common findings were loss of peripupillary ruff in 10 patients (29.4%) and pigment dispersion following pupil dilation in 14 patients (41.1%). Pigmentation in the inferior angle and Sampaolesi's line on the inferior angle seem to be the most common early findings associated with PEX. Special attention should be paid to these findings in cases with ocular hypertension for proper management.

  16. Light-sheet microscopy for everyone? Experience of building an OpenSPIM to study flatworm development.

    PubMed

    Girstmair, Johannes; Zakrzewski, Anne; Lapraz, François; Handberg-Thorsager, Mette; Tomancak, Pavel; Pitrone, Peter Gabriel; Simpson, Fraser; Telford, Maximilian J

    2016-06-30

    Selective plane illumination microscopy (SPIM a type of light-sheet microscopy) involves focusing a thin sheet of laser light through a specimen at right angles to the objective lens. As only the thin section of the specimen at the focal plane of the lens is illuminated, out of focus light is naturally absent and toxicity due to light (phototoxicity) is greatly reduced enabling longer term live imaging. OpenSPIM is an open access platform (Pitrone et al. 2013 and OpenSPIM.org) created to give new users step-by-step instructions on building a basic configuration of a SPIM microscope, which can in principle be adapted and upgraded to each laboratory's own requirements and budget. Here we describe our own experience with the process of designing, building, configuring and using an OpenSPIM for our research into the early development of the polyclad flatworm Maritigrella crozieri - a non-model animal. Our OpenSPIM builds on the standard design with the addition of two colour laser illumination for simultaneous detection of two probes/molecules and dual sided illumination, which provides more even signal intensity across a specimen. Our OpenSPIM provides high resolution 3d images and time lapse recordings, and we demonstrate the use of two colour lasers and the benefits of two color dual-sided imaging. We used our microscope to study the development of the embryo of the polyclad flatworm M. crozieri. The capabilities of our microscope are demonstrated by our ability to record the stereotypical spiral cleavage pattern of M. crozieri with high-speed multi-view time lapse imaging. 3D and 4D (3D + time) reconstruction of early development from these data is possible using image registration and deconvolution tools provided as part of the open source Fiji platform. We discuss our findings on the pros and cons of a self built microscope. We conclude that home-built microscopes, such as an OpenSPIM, together with the available open source software, such as MicroManager and Fiji, make SPIM accessible to anyone interested in having continuous access to their own light-sheet microscope. However, building an OpenSPIM is not without challenges and an open access microscope is a worthwhile, if significant, investment of time and money. Multi-view 4D microscopy is more challenging than we had expected. We hope that our experience gained during this project will help future OpenSPIM users with similar ambitions.

  17. Refractory open-angle glaucoma after neodymium-yttrium-aluminum-garnet laser lysis of vitreous floaters.

    PubMed

    Cowan, Lisa A; Khine, Kay T; Chopra, Vikas; Fazio, Doreen T; Francis, Brian A

    2015-01-01

    To illustrate 3 cases of chronic open-angle glaucoma secondary to the neodymium-yttrium-aluminum-garnet (Nd:YAG) laser vitreolysis procedure for symptomatic vitreous floaters. Observational case series. Location of the study was the Doheny Eye Institute. Three eyes of 2 patients who developed chronic open-angle glaucoma after Nd:YAG vitreolysis for symptomatic floaters presenting with very high intraocular pressure (IOP >40 mm Hg) were selected. The time from the laser treatment to the onset of elevated pressure ranges from 1 week to 8 months. There was no associated inflammation, steroid use, or other identifiable cause of chronic IOP elevation. All eyes were treated initially with glaucoma medication, followed by selective laser trabeculoplasty (SLT) and eventually glaucoma surgery (Trabectome) in 2 eyes for disease management. In all eyes, intraocular pressures were eventually stabilized within a normal pressure range from 18 to 38 months following Nd:YAG vitreolysis. At the latest follow-up post surgery, all eyes had intraocular pressures of 22 mm Hg or less with or without medications. Secondary open-angle glaucoma is a complication of Nd:YAG vitreolysis for symptomatic floaters that may present with an increase in intraocular pressure immediately, or many months after the surgery. Furthermore this complication may be permanent and require chronic medical therapy or glaucoma surgery. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. A target field design of open multi-purpose RF coil for musculoskeletal MR imaging at 3T.

    PubMed

    Gao, Fei; Zhang, Rui; Zhou, Diange; Wang, Xiaoying; Huang, Kefu; Zhang, Jue

    2016-10-01

    Musculoskeletal MR imaging under multi-angle situations plays an increasingly important role in assessing joint and muscle tissues system. However, there are still limitations due to the closed structures of most conventional RF coils. In this study, a time-harmonic target-field method was employed to design open multi-purpose coil (OMC) for multi-angle musculoskeletal MR imaging. The phantom imaging results suggested that the proposed OMC could achieve homogeneously distributed magnetic field and high signal-to-noise ratio (SNR) of 239.04±0.83 in the region of interest (ROI). The maximum temperature in the heating hazard test was 16°C lower than the standard regulation, which indicated the security of the designed OMC. Furthermore, to demonstrate the effectiveness of the proposed OMC for musculoskeletal MR imaging, especially for multi-angle imaging, a healthy volunteer was examined for MR imaging of elbow, ankle and knee using OMC. The in vivo imaging results showed that the proposed OMC is effective for MR imaging of musculoskeletal tissues at different body parts, with satisfied B1 field homogeneity and SNR. Moreover, the open structure of the OMC could provide a large joint movement region. The proposed open multi-purpose coil is feasible for musculoskeletal MR imaging, and potentially, it is more suitable for the evaluation of musculoskeletal tissues under multi-angle conditions. Copyright © 2016. Published by Elsevier Inc.

  19. 46 CFR 42.20-12 - Conditions of equilibrium.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., heel, and trim, is below the lower edge of any opening through which progressive flooding can take... angle of heel. The angle of heel due to unsymmetrical flooding does not exceed 15 degrees. If no part of the deck is immersed, an angle of heel of up to 17 degrees may be accepted. (d) Metacentric height...

  20. 46 CFR 42.20-12 - Conditions of equilibrium.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., heel, and trim, is below the lower edge of any opening through which progressive flooding can take... angle of heel. The angle of heel due to unsymmetrical flooding does not exceed 15 degrees. If no part of the deck is immersed, an angle of heel of up to 17 degrees may be accepted. (d) Metacentric height...

  1. Modeling to study the role of catalyst in the formation of graphitic shells during carbon nanofiber growth subjected to reactive plasma

    NASA Astrophysics Data System (ADS)

    Gupta, Ravi; Gupta, Neha; Sharma, Suresh C.

    2018-04-01

    An analytical model to study the role of a metal catalyst nanofilm in the nucleation, growth, and resulting structure of carbon nanofibers (CNFs) in low-temperature hydrogen diluted acetylene plasma has been developed. The model incorporates the nanostructuring of thin catalyst films, growth of CNF, restructuring of catalyst nanoparticles during growth, and its repercussion on the resulting structure (alignment of rolled graphene sheets around catalyst nanoparticles) by taking into account the plasma sheath formalization, kinetics of neutrals and positively charged species in the reactive plasma, flux of plasma species onto the catalyst front surface, and numerous surface reactions for carbon generation. In order to examine the influence of the catalyst film on the growth of CNFs, the numerical solutions of the model equations have been obtained for experimentally determined initial conditions and glow discharge plasma parameters. From the solutions obtained, we found that nanostructuring of thin films leads to the formation of small nanoparticles with high surface number density. The CNF nucleates over these small-sized nanoparticles grow faster and attain early saturation because of the quick poisoning of small-sized catalyst particles, and contain only a few graphitic shells. However, thick nanofilms result in shorter CNFs with large diameters composed of many graphitic shells. Moreover, we found that the inclination of graphitic shells also depends on the extent up to which the catalyst can reconstruct itself during the growth. The small nanoparticles show much greater elongation along the growth axis and also show a very small difference between their tip and base diameter during the growth due to which graphitic shells align at very small angles as compared to the larger nanoparticles. The present study is useful to synthesize the thin and more extended CNFs/CNTs having a smaller opening angle (inclination angle of graphene layers) as the opening angle has a significant influence on their field emission properties. The comparisons of these theoretical findings to the experimental observations confirm the adequacy of the proposed model.

  2. Retinal Adaptation Abnormalities in Primary Open-Angle Glaucoma

    PubMed Central

    Dul, Mitchell; Ennis, Robert; Radner, Shira; Lee, Barry; Zaidi, Qasim

    2015-01-01

    Purpose. Dynamic color and brightness adaptation are crucial for visual functioning. The effects of glaucoma on retinal ganglion cells (RGCs) could compromise these functions. We have previously used slow dynamic changes of light at moderate intensities to measure the speed and magnitude of subtractive adaptation in RGCs. We used the same procedure to test if RGC abnormalities cause slower and weaker adaptation for patients with glaucoma when compared to age-similar controls. We assessed adaptation deficits in specific classes of RGCs by testing along the three cardinal color axes that isolate konio, parvo, and magno RGCs. Methods. For one eye each of 10 primary open-angle glaucoma patients and their age-similar controls, we measured the speed and magnitude of adapting to 1/32 Hz color modulations along the three cardinal axes, at central fixation and 8° superior, inferior, nasal, and temporal to fixation. Results. In all 15 comparisons (5 locations × 3 color axes), average adaptation was slower and weaker for glaucoma patients than for controls. Adaptation developed slower at central targets than at 8° eccentricities for controls, but not for patients. Adaptation speed and magnitude differed between affected and control eyes even at retinal locations showing no visual field loss with clinical perimetry. Conclusions. Neural adaptation is weaker in glaucoma patients for all three classes of RGCs. Since adaptation abnormalities are manifested even at retinal locations not exhibiting a visual field loss, this novel form of assessment may offer a functional insight into glaucoma and an early diagnosis tool. PMID:25613950

  3. PROSPECTS FOR JOINT GRAVITATIONAL WAVE AND SHORT GAMMA-RAY BURST OBSERVATIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clark, J.; Evans, H.; Fairhurst, S.

    2015-08-10

    We present a detailed evaluation of the expected rate of joint gravitational-wave (GW) and short gamma-ray burst (GRB) observations over the coming years. We begin by evaluating the improvement in distance sensitivity of the GW search that arises from using the GRB observation to restrict the time and sky location of the source. We argue that this gives a 25% increase in sensitivity when compared to an all-sky, all-time search, corresponding to more than double the number of detectable GW signals associated with GRBs. Using this, we present the expected rate of joint observations with the advanced LIGO and Virgomore » instruments, taking into account the expected evolution of the GW detector network. We show that in the early advanced GW detector observing runs, from 2015 to 2017, there is only a small chance of a joint observation. However, as the detectors approach their design sensitivities, there is a good chance of joint observations, provided wide field GRB satellites, such as Fermi and the Inter planetary Network, continue operation. The rate will also depend critically upon the nature of the progenitor, with neutron star-black hole systems observable to greater distances than double neutron star systems. The relative rate of binary mergers and GRBs will depend upon the jet opening angle of GRBs. Consequently, joint observations, as well as accurate measurement of both the GRB rate and binary merger rates, will allow for an improved estimation of the opening angle of GRBs.« less

  4. Northern Alberta remote teleglaucoma program: clinical outcomes and patient disposition.

    PubMed

    Verma, Sanam; Arora, Sourabh; Kassam, Faazil; Edwards, Marianne C; Damji, Karim F

    2014-04-01

    To review the diagnostic outcomes and clinical referral pathways of patients assessed and managed through a collaborative care patient-centred teleglaucoma program. Retrospective cohort study. Eligible patients were those assessed by the referring optometrist or ophthalmologist to be open-angle glaucoma suspects or to have definite early open-angle glaucoma. A glaucoma specialist graded each case through virtual consultation. Clinical referral pathways were noted: in-person consultation with glaucoma specialist, repeat teleconsultation, collaborative glaucoma management with optometrist, or referral for nonglaucomatous ophthalmic pathology. A total of 247 patients were referred to the program from 2008 to 2012. Of all teleconsults, 31.1% were diagnosed with glaucoma, 42.1% were suspects, and 26.7% were unaffected. Of all patients, 27% were referred for in-person glaucoma evaluation; 69% of patients could be managed by their referring optometrist, with 48% of patients requiring repeat teleconsultation. Treatment was initiated before being seen for 87% of patients with definite glaucoma and 28% of glaucoma suspects. Of all patients seen through the remote teleglaucoma program, most did not require an in-person consultation with an ophthalmologist and could be managed through distance collaboration. For the approximately one third who were diagnosed with glaucoma based on virtual assessment, medication was started in the majority of cases and in-person consultation was arranged. Further studies to validate and consider cost-effectiveness of this system are under way. © 2013 Canadian Ophthalmological Society Published by Canadian Ophthalmological Society All rights reserved.

  5. Demonstration of angle widening using EyeCam after laser peripheral iridotomy in eyes with angle closure.

    PubMed

    Perera, Shamira A; Quek, Desmond T; Baskaran, Mani; Tun, Tin A; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2010-06-01

    To evaluate EyeCam in detecting changes in angle configuration after laser peripheral iridotomy (LPI) in comparison to gonioscopy, the reference standard. Prospective comparative study. Twenty-four subjects (24 eyes) with primary angle-closure glaucoma (PACG) were recruited. Gonioscopy and EyeCam (Clarity Medical Systems) imaging of all 4 angle quadrants were performed, before and 2 weeks after LPI. Images were graded according to angle structures visible by an observer masked to clinical data or the status of LPI, and were performed in a random order. Angle closure in a quadrant was defined as the inability to visualize the posterior trabecular meshwork. We determined the number of quadrants with closed angles and the mean number of clock hours of angle closure before and after LPI in comparison to gonioscopy. Using EyeCam, all 24 eyes showed at least 1 quadrant of angle widening after LPI. The mean number of clock hours of angle closure decreased significantly, from 8.15 +/- 3.47 clock hours before LPI to 1.75 +/- 2.27 clock hours after LPI (P < .0001, Wilcoxon signed rank test). Overall, gonioscopy showed 1.0 +/- 1.41 (95% CI, 0.43-1.57) quadrants opening from closed to open after LPI compared to 2.0 +/- 1.28 (95% CI, 1.49-2.51, P = .009) quadrants with EyeCam. Intra-observer reproducibility of grading the extent of angle closure in clock hours in EyeCam images was moderate to good (intraclass correlation coefficient 0.831). EyeCam may be used to document changes in angle configuration after LPI in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  6. Hiding an elephant: heavy sterile neutrino with large mixing angle does not contradict cosmology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bezrukov, F.; Chudaykin, A.; Gorbunov, D., E-mail: Fedor.Bezrukov@manchester.ac.uk, E-mail: chudy@ms2.inr.ac.ru, E-mail: gorby@ms2.inr.ac.ru

    We study a model of a keV-scale sterile neutrino with a relatively large mixing with the Standard Model sector. Usual considerations predict active generation of such particles in the early Universe, which leads to constraints from the total Dark Matter density and absence of X-ray signal from sterile neutrino decay. These bounds together may deem any attempt of creation of the keV scale sterile neutrino in the laboratory unfeasible. We argue that for models with a hidden sector coupled to the sterile neutrino these bounds can be evaded, opening new perspectives for the direct studies at neutrino experiments such asmore » Troitsk ν-mass and KATRIN. We estimate the generation of sterile neutrinos in scenarios with the hidden sector dynamics keeping the sterile neutrinos either massless or superheavy in the early Universe. In both cases the generation by oscillations from active neutrinos in plasma is suppressed.« less

  7. Dental and skeletal components of Class II open bite treatment with a modified Thurow appliance

    PubMed Central

    Jacob, Helder Baldi; dos Santos-Pinto, Ary; Buschang, Peter H.

    2014-01-01

    Introduction Due to the lack of studies that distinguish between dentoalveolar and basal changes caused by the Thurow appliance, this clinical study, carried out by the School of Dentistry - State University of São Paulo/Araraquara, aimed at assessing the dental and skeletal changes induced by modified Thurow appliance. Methods The sample included an experimental group comprising 13 subjects aged between 7 and 10 years old, with Class II malocclusion and anterior open bite, and a control group comprising 22 subjects similar in age, sex and mandibular plane angle. Maxillary/mandibular, horizontal/vertical, dental/skeletal movements (ANS, PNS, U1, U6, Co, Go, Pog, L1, L6) were assessed, based on 14 landmarks, 8 angles (S-N-ANS, SNA, PPA, S-N-Pog, SNB, MPA, PP/MPA, ANB) and 3 linear measures (N-Me, ANS-Me, S-Go). Results Treatment caused significantly greater angle decrease between the palatal and the mandibular plane of the experimental group, primarily due to an increase in the palatal plane angle. ANB, SNA and S-N-ANS angles significantly decreased more in patients from the experimental group. PNS was superiorly remodeled. Lower face height (ANS-Me) decreased in the experimental group and increased in the control group. Conclusions The modified Thurow appliance controlled vertical and horizontal displacements of the maxilla, rotated the maxilla and improved open bite malocclusion, decreasing lower facial height. PMID:24713556

  8. Open-ocean fish reveal an omnidirectional solution to camouflage in polarized environments.

    PubMed

    Brady, Parrish C; Gilerson, Alexander A; Kattawar, George W; Sullivan, James M; Twardowski, Michael S; Dierssen, Heidi M; Gao, Meng; Travis, Kort; Etheredge, Robert Ian; Tonizzo, Alberto; Ibrahim, Amir; Carrizo, Carlos; Gu, Yalong; Russell, Brandon J; Mislinski, Kathryn; Zhao, Shulei; Cummings, Molly E

    2015-11-20

    Despite appearing featureless to our eyes, the open ocean is a highly variable environment for polarization-sensitive viewers. Dynamic visual backgrounds coupled with predator encounters from all possible directions make this habitat one of the most challenging for camouflage. We tested open-ocean crypsis in nature by collecting more than 1500 videopolarimetry measurements from live fish from distinct habitats under a variety of viewing conditions. Open-ocean fish species exhibited camouflage that was superior to that of both nearshore fish and mirrorlike surfaces, with significantly higher crypsis at angles associated with predator detection and pursuit. Histological measurements revealed that specific arrangements of reflective guanine platelets in the fish's skin produce angle-dependent polarization modifications for polarocrypsis in the open ocean, suggesting a mechanism for natural selection to shape reflectance properties in this complex environment. Copyright © 2015, American Association for the Advancement of Science.

  9. The Properties of Extragalactic Radio Jets

    NASA Astrophysics Data System (ADS)

    Finke, Justin

    2018-01-01

    I show that by assuming a standard Blandford-Konigl jet, it is possible to determine the speed (bulk Lorentz factor) and orientation (angle to the line of sight) of self-similar parsec-scale blazar jets by using four measured quantities: the core radio flux, the extended radio flux, the magnitude of the core shift between two frequencies, and the apparent jet opening angle. Once the bulk Lorentz factor and angle to the line of sight of a jet are known, it is possible to compute their Doppler factor, magnetic field, and intrinsic jet opening angle. I use data taken from the literature and marginalize over nuisance parameters associated with the electron distribution and equipartition, to compute these quantities, albeit with large errors. The results have implications for the resolution of the TeV BL Lac Doppler factor crisis and the production of jets from magnetically arrested disks.

  10. Recent ARPES experiments on quasi-1D bulk materials and artificial structures.

    PubMed

    Grioni, M; Pons, S; Frantzeskakis, E

    2009-01-14

    The spectroscopy of quasi-one-dimensional (1D) systems has been a subject of strong interest since the first experimental observations of unusual line shapes in the early 1990s. Angle-resolved photoemission (ARPES) measurements performed with increasing accuracy have greatly broadened our knowledge of the properties of bulk 1D materials and, more recently, of artificial 1D structures. They have yielded a direct view of 1D bands, of open Fermi surfaces, and of characteristic instabilities. They have also provided unique microscopic evidence for the non-conventional, non-Fermi-liquid, behavior predicted by theory, and for strong and singular interactions. Here we briefly review some of the remarkable experimental results obtained in the last decade.

  11. A comparison of latanoprost monotherapy with a combination therapy of timolol/dorzolamide in patients with primary open-angle glaucoma.

    PubMed

    Caça, Ihsan; Simsek, Hüseyin; Unlü, Kaan; Ari, Seyhmus; Keklikçi, Ugur

    2006-01-01

    We compared latanoprost monotherapy therapy with timolol/ dorzolamide in patients with primary open-angle glaucoma to evaluate the effects on intraocular pressure (IOP) and occurrence of adverse events. IOP and topical side effects were evaluated at the beginning, first, and third months. Mean IOP was decreased at the third month. The most common side effect was hyperemia (43.6%). We concluded that latanoprost reduces IOP better than fixed combination and its topical side effects are tolerable.

  12. Static balance according to hip joint angle of unsupported leg during one-leg standing.

    PubMed

    Cha, Ju-Hyung; Kim, Jang-Joon; Ye, Jae-Gwan; Lee, Seul-Ji; Hong, Jeong-Mi; Choi, Hyun-Kyu; Choi, Ho-Suk; Shin, Won-Seob

    2017-05-01

    [Purpose] This study aimed to determine static balance according to hip joint angle of the unsupported leg during one-leg standing. [Subjects and Methods] Subjects included 45 healthy adult males and females in their 20s. During one-leg standing on the non-dominant leg, the position of the unsupported leg was classified according to hip joint angles of point angle was class. Static balance was then measured using a force plate with eyes open and closed. The total length, sway velocity, maximum deviation, and velocity on the mediolateral and anteroposterior axes of center of pressure were measured. [Results] In balance assessment with eyes open, there were significant differences between groups according to hip joint angle, except for maximum deviation on the anteroposterior axis. In balance assessment with eyes closed, there were significant differences between total length measurements at 0° and 30°, 60° and between 30° and 90°. There were significant differences between sway velocity measurements at 0° and 30° and between 30° and 90°. [Conclusion] Thus, there were differences in static balance according to hip joint angle. It is necessary to clearly identify the hip joint angle during one-leg standing testing.

  13. Retcam fluorescein gonioangiography: a new modality for early detection of angle neovascularization in diabetic retinopathy.

    PubMed

    Azad, Rajvardhan; Arora, Tarun; Sihota, Ramanjit; Chandra, Parijat; Mahajan, Deepankur; Sain, Siddarth; Sharma, Yograj

    2013-10-01

    To evaluate the role of Retcam fluorescein gonioangiography in detecting neovascularization of the angle and correlate the same with gonioscopy in diabetic retinopathy. One hundred and fifty eyes of 150 patients (25 each of mild, moderate, severe, very severe nonproliferative diabetic retinopathy (NPDR) proliferative diabetic retinopathy (PDR); and PDR with high-risk characteristics) were recruited. They underwent complete ocular examination including applanation tonometry, gonioscopy, Retcam fluorescein gonioangiography, and fundus fluorescein angiography. Using Retcam fluorescein gonioangiography, of 150 eyes neovascularization of the angle was detected in 37 eyes (24.66%) compared with 22 eyes (14.66%) on gonioscopy (P = 0.04). Small newly formed vessels were evident only with Retcam fluorescein gonioangiography. In 10 of 50 patients (20%) with severe/very severe NPDR, angle neovascularization was appreciable on Retcam fluorescein angiography compared with 5 patients (10%) on gonioscopy. Similarly, 25 of 50 patients (50%) with PDR/PDR with high-risk characteristics had neovascularization of the angle on Retcam gonioangiography compared with 17 (34%) on gonioscopy. Retcam fluorescein gonioangiography is a novel technique for early detection of angle neovascularization in diabetic retinopathy and hence preventing progression to neovascular glaucoma. The objective nature of this test helps in precise decision making compared with gonioscopy for early intervention especially in cases of pre-PDR.

  14. Comparison of Laser Scanning Diagnostic Devices for Early Glaucoma Detection.

    PubMed

    Schulze, Andreas; Lamparter, Julia; Pfeiffer, Norbert; Berisha, Fatmire; Schmidtmann, Irene; Hoffmann, Esther M

    2015-08-01

    To compare the diagnostic accuracy and to evaluate the correlation of optic nerve head and retinal nerve fiber layer thickness values between Fourier-Domain optical coherence tomography (FD-OCT), confocal scanning laser ophthalmoscopy (CSLO), and scanning laser polarimetry (SLP) for early glaucoma detection. Ninety-three patients with early open-angle glaucoma, 58 patients with ocular hypertension, and 60 healthy control subjects were included in this observational, cross-sectional study. All study participants underwent FD-OCT (RTVue-100), CSLO (HRT3), and SLP (GDx VCC) imaging of the optic nerve head and the retinal nerve fiber layer. Area under the receiver operating characteristic curves (AUROC) and Bland-Altman analysis were performed. The parameters with the highest diagnostic accuracy were found for FD-OCT cup-to-disc ratio (AUROC=0.841), for SLP NFI (AUROC=0.835), and for CSLO cup-to-disc ratio (AUROC=0.789). Diagnostic accuracy of the best CSLO and SLP parameter was similar (P=0.259). There was a small statistically significant difference between the best CSLO and FD-OCT parameters for differentiating between glaucoma and healthy eyes (P=0.047). FD-OCT and SLP have a similarly good diagnostic ability to distinguish between early glaucoma and healthy subjects. The diagnostic accuracy of CSLO was comparable with SLP and marginally lower compared with FD-OCT.

  15. Correlation between Macular Thickness and Visual Field in Early Open Angle Glaucoma: A Cross-Sectional Study.

    PubMed

    Fallahi Motlagh, Behzad; Sadeghi, Ali

    2017-01-01

    The aim of this study was to correlate macular thickness and visual field parameters in early glaucoma. A total of 104 eyes affected with early glaucoma were examined in a cross-sectional, prospective study. Visual field testing using both standard automated perimetry (SAP) and shortwave automated perimetry (SWAP) was performed. Global visual field parameters, including mean deviation (MD) and pattern standard deviation (PSD), were recorded and correlated with spectral domain optical coherence tomography (SD-OCT)-measured macular thickness and asymmetry. Average macular thickness correlated significantly with all measures of visual field including MD-SWAP (r = 0.42), MD-SAP (r = 0.41), PSD-SWAP (r = -0.23), and PSD-SAP (r = -0.21), with P-values <0.001 for all correlations. The mean MD scores (using both SWAP and SAP) were significantly higher in the eyes with thin than in those with intermediate average macular thickness. Intraeye (superior macula thickness - inferior macula thickness) asymmetries correlated significantly with both PSD-SWAP (r = 0.63, P < 0.001) and PSD-SAP (r = 0.26, P = 0.01) scores. This study revealed a significant correlation between macular thickness and visual field parameters in early glaucoma. The results of this study should make macular thickness measurements even more meaningful to glaucoma specialists.

  16. Comparative assessment of bone pose estimation using Point Cluster Technique and OpenSim.

    PubMed

    Lathrop, Rebecca L; Chaudhari, Ajit M W; Siston, Robert A

    2011-11-01

    Estimating the position of the bones from optical motion capture data is a challenge associated with human movement analysis. Bone pose estimation techniques such as the Point Cluster Technique (PCT) and simulations of movement through software packages such as OpenSim are used to minimize soft tissue artifact and estimate skeletal position; however, using different methods for analysis may produce differing kinematic results which could lead to differences in clinical interpretation such as a misclassification of normal or pathological gait. This study evaluated the differences present in knee joint kinematics as a result of calculating joint angles using various techniques. We calculated knee joint kinematics from experimental gait data using the standard PCT, the least squares approach in OpenSim applied to experimental marker data, and the least squares approach in OpenSim applied to the results of the PCT algorithm. Maximum and resultant RMS differences in knee angles were calculated between all techniques. We observed differences in flexion/extension, varus/valgus, and internal/external rotation angles between all approaches. The largest differences were between the PCT results and all results calculated using OpenSim. The RMS differences averaged nearly 5° for flexion/extension angles with maximum differences exceeding 15°. Average RMS differences were relatively small (< 1.08°) between results calculated within OpenSim, suggesting that the choice of marker weighting is not critical to the results of the least squares inverse kinematics calculations. The largest difference between techniques appeared to be a constant offset between the PCT and all OpenSim results, which may be due to differences in the definition of anatomical reference frames, scaling of musculoskeletal models, and/or placement of virtual markers within OpenSim. Different methods for data analysis can produce largely different kinematic results, which could lead to the misclassification of normal or pathological gait. Improved techniques to allow non-uniform scaling of generic models to more accurately reflect subject-specific bone geometries and anatomical reference frames may reduce differences between bone pose estimation techniques and allow for comparison across gait analysis platforms.

  17. Dynamic Cytology and Transcriptional Regulation of Rice Lamina Joint Development1[OPEN

    PubMed Central

    2017-01-01

    Rice (Oryza sativa) leaf angle is determined by lamina joint and is an important agricultural trait determining leaf erectness and, hence, the photosynthesis efficiency and grain yield. Genetic studies reveal a complex regulatory network of lamina joint development; however, the morphological changes, cytological transitions, and underlying transcriptional programming remain to be elucidated. A systemic morphological and cytological study reveals a dynamic developmental process and suggests a common but distinct regulation of the lamina joint. Successive and sequential cell division and expansion, cell wall thickening, and programmed cell death at the adaxial or abaxial sides form the cytological basis of the lamina joint, and the increased leaf angle results from the asymmetric cell proliferation and elongation. Analysis of the gene expression profiles at four distinct developmental stages ranging from initiation to senescence showed that genes related to cell division and growth, hormone synthesis and signaling, transcription (transcription factors), and protein phosphorylation (protein kinases) exhibit distinct spatiotemporal patterns during lamina joint development. Phytohormones play crucial roles by promoting cell differentiation and growth at early stages or regulating the maturation and senescence at later stages, which is consistent with the quantitative analysis of hormones at different stages. Further comparison with the gene expression profile of leaf inclination1, a mutant with decreased auxin and increased leaf angle, indicates the coordinated effects of hormones in regulating lamina joint. These results reveal a dynamic cytology of rice lamina joint that is fine-regulated by multiple factors, providing informative clues for illustrating the regulatory mechanisms of leaf angle and plant architecture. PMID:28500269

  18. PROTOSTELLAR OUTFLOWS AND RADIATIVE FEEDBACK FROM MASSIVE STARS. II. FEEDBACK, STAR-FORMATION EFFICIENCY, AND OUTFLOW BROADENING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuiper, Rolf; Turner, Neal J.; Yorke, Harold W., E-mail: rolf.kuiper@uni-tuebingen.de, E-mail: Neal.J.Turner@jpl.nasa.gov, E-mail: Harold.W.Yorke@jpl.nasa.gov

    2016-11-20

    We perform two-dimensional axially symmetric radiation hydrodynamic simulations to assess the impact of outflows and radiative force feedback from massive protostars by varying when the protostellar outflow starts, and to determine the ratio of ejection to accretion rates and the strength of the wide-angle disk wind component. The star-formation efficiency, i.e., the ratio of final stellar mass to initial core mass, is dominated by radiative forces and the ratio of outflow to accretion rates. Increasing this ratio has three effects. First, the protostar grows slower with a lower luminosity at any given time, lowering radiative feedback. Second, bipolar cavities clearedmore » by the outflow become larger, further diminishing radiative feedback on disk and core scales. Third, the higher momentum outflow sweeps up more material from the collapsing envelope, decreasing the protostar's potential mass reservoir via entrainment. The star-formation efficiency varies with the ratio of ejection to accretion rates from 50% in the case of very weak outflows to as low as 20% for very strong outflows. At latitudes between the low-density bipolar cavity and the high-density accretion disk, wide-angle disk winds remove some of the gas, which otherwise would be part of the accretion flow onto the disk; varying the strength of these wide-angle disk winds, however, alters the final star-formation efficiency by only ±6%. For all cases, the opening angle of the bipolar outflow cavity remains below 20° during early protostellar accretion phases, increasing rapidly up to 65° at the onset of radiation pressure feedback.« less

  19. iStent trabecular micro-bypass stent for open-angle glaucoma

    PubMed Central

    Le, Kim; Saheb, Hady

    2014-01-01

    Trabecular micro-bypass stents, commonly known as iStents, are micro-invasive glaucoma surgery (MIGS) devices used to treat open-angle glaucoma. Like other MIGS procedures that enhance trabecular outflow, the iStent lowers intraocular pressure (IOP) by creating a direct channel between the anterior chamber and Schlemm’s canal. iStents are typically implanted at the time of phacoemulsification for patients with open-angle glaucoma and visually significant cataracts. This review summarizes the published data regarding the efficacy, safety, and cost considerations of trabecular micro-bypass stents. Most studies found statistically significant reductions in mean IOP and ocular medication use after combined phacoemulsification with single or double iStent implantation. The devices were found to be very safe, with a safety profile similar to that of cataract surgery. Complications were infrequent, with the most common complications being temporary stent obstruction or malposition, which resolved with observation or secondary procedures. Future studies are needed to evaluate long-term outcomes, patient satisfaction, cost effectiveness, and expanded indications. PMID:25284980

  20. A comparison of gait biomechanics of flip-flops, sandals, barefoot and shoes

    PubMed Central

    2013-01-01

    Background Flip-flops and sandals are popular choices of footwear due to their convenience. However, the effects of these types of footwear on lower extremity biomechanics are still poorly understood. Therefore, the objective of this study was to investigate differences in ground reaction force (GRF), center of pressure (COP) and lower extremity joint kinematic and kinetic variables during level-walking in flip-flops, sandals and barefoot compared to running shoes. Methods Ten healthy males performed five walking trials in the four footwear conditions at 1.3 m/s. Three-dimensional GRF and kinematic data were simultaneously collected. Results A smaller loading rate of the 1st peak vertical GRF and peak propulsive GRF and greater peak dorsiflexion moment in early stance were found in shoes compared to barefoot, flip-flops and sandals. Barefoot walking yielded greater mediolateral COP displacement, flatter foot contact angle, increased ankle plantarflexion contact angle, and smaller knee flexion contact angle and range of motion compared to all other footwear. Conclusions The results from this study indicate that barefoot, flip-flops and sandals produced different peak GRF variables and ankle moment compared to shoes while all footwear yield different COP and ankle and knee kinematics compared to barefoot. The findings may be helpful to researchers and clinicians in understanding lower extremity mechanics of open-toe footwear. PMID:24196492

  1. Juxtacanalicular tissue in pigmentary and primary open angle glaucoma. The hydrodynamic role of pigment and other constituents.

    PubMed

    Murphy, C G; Johnson, M; Alvarado, J A

    1992-12-01

    We tested the hypothesis that obstruction of the juxtacanalicular tissues, by melanin granules in pigmentary glaucoma and by other impermeable material in primary open angle glaucoma, leads to the development of a chronic glaucomatous condition. The distribution and concentration of melanin and other impermeable materials in the juxtacanalicular tissues and elsewhere in the trabecular meshwork was determined in 13 specimens. Six specimens were from patients with pigmentary glaucoma, two from patients with pigment dispersion syndrome, and three from patients with primary open angle glaucoma, as well as two from normal subjects. The effect of these materials on flow resistance was estimated using two hydrodynamic models. In model A, the electron-lucent spaces of the juxtacanalicular tissue were assumed to be open spaces, while in model B, these spaces and spaces filled with ground substance were assumed to be gel filled. In pigmentary glaucoma, 3.5% of the pigment was found in the juxtacanalicular tissue, while 96.5% was found in the corneoscleral and uveoscleral tissues. Permeabilities calculated according to model A were much higher than those expected from estimates of outflow facility in all groups, in agreement with the previous report of Ethier et al. The gel-filled spaces available for fluid flow, as determined by model B, showed no statistically demonstrable differences (pigmentary glaucoma, 32.9%; primary open angle glaucoma, 36.6%; pigment dispersion syndrome, 43.4%; normal, 44.1%). Furthermore, the amount of pigment present in the juxtacanalicular tissue was determined to have a negligible influence on permeability. Thus, the development of the chronic glaucomatous condition cannot be directly attributed to pigment accumulation in the juxtacanalicular tissue in pigmentary glaucoma.

  2. Percutaneous versus traditional and paraspinal posterior open approaches for treatment of thoracolumbar fractures without neurologic deficit: a meta-analysis.

    PubMed

    Sun, Xiang-Yao; Zhang, Xi-Nuo; Hai, Yong

    2017-05-01

    This study evaluated differences in outcome variables between percutaneous, traditional, and paraspinal posterior open approaches for traumatic thoracolumbar fractures without neurologic deficit. A systematic review of PubMed, Cochrane, and Embase was performed. In this meta-analysis, we conducted online searches of PubMed, Cochrane, Embase using the search terms "thoracolumbar fractures", "lumbar fractures", ''percutaneous'', "minimally invasive", ''open", "traditional", "posterior", "conventional", "pedicle screw", "sextant", and "clinical trial". The analysis was performed on individual patient data from all the studies that met the selection criteria. Clinical outcomes were expressed as risk difference for dichotomous outcomes and mean difference for continuous outcomes with 95 % confidence interval. Heterogeneity was assessed using the χ 2 test and I 2 statistics. There were 4 randomized controlled trials and 14 observational articles included in this analysis. Percutaneous approach was associated with better ODI score, less Cobb angle correction, less Cobb angle correction loss, less postoperative VBA correction, and lower infection rate compared with open approach. Percutaneous approach was also associated with shorter operative duration, longer intraoperative fluoroscopy, less postoperative VAS, and postoperative VBH% in comparison with traditional open approach. No significant difference was found in Cobb angle correction, postoperative VBA, VBA correction loss, Postoperative VBH%, VBH correction loss, and pedicle screw misplacement between percutaneous approach and open approach. There was no significant difference in operative duration, intraoperative fluoroscopy, postoperative VAS, and postoperative VBH% between percutaneous approach and paraspianl approach. The functional and the radiological outcome of percutaneous approach would be better than open approach in the long term. Although trans-muscular spatium approach belonged to open fixation methods, it was strictly defined as less invasive approach, which provided less injury to the paraspinal muscles and better reposition effect.

  3. Glaucoma and clinical characteristics in Vietnamese Americans.

    PubMed

    Peng, Pai-Huei; Manivanh, Richard; Nguyen, Ngoc; Weinreb, Robert N; Lin, Shan C

    2011-08-01

    To assess the proportions of glaucoma types and clinical characteristics in Vietnamese Americans in a single-center, retrospective study. Medical charts of Vietnamese-American patients who visited a single private practice in Northern California from 1998-2007 were reviewed. The main outcome measures included the distribution and characteristics of glaucoma types, and clinical parameters associated with the presence of various glaucomas. Data from 2247 patients aged 18-98 years were reviewed. Glaucoma was determined for 305 patients (13.6%). Among this group, 54.8% had primary open-angle glaucoma (POAG), 26.9% had primary angle-closure glaucoma (PACG), 13.4% had mixed mechanism glaucoma (MMG), and 4.9% had secondary glaucoma. In the MMG group (41 patients), 27 patients who initially had open angles developed narrow angles and underwent laser peripheral iridotomy (LPI) with a mean follow up of 6.4 years from the time of iridotomy. The other 13 patients had glaucoma progression with open angles after LPI. One POAG patient had neovascular glaucoma due to retinal vein occlusion several years later. Compared to the PACG group, the MMG group had significantly lower baseline intraocular pressure (25.0 vs. 20.2 mmHg, p = 0.007) but with no difference in biometry. POAG is the major type of glaucoma in this clinic-based Vietnamese population. However, Vietnamese appear to have a relatively higher proportion of PACG than Caucasians and those of African descent. It is recommended that gonioscopy be part of the regular eye check-up for adult Vietnamese patients.

  4. Edge contact angle and modified Kelvin equation for condensation in open pores.

    PubMed

    Malijevský, Alexandr; Parry, Andrew O; Pospíšil, Martin

    2017-08-01

    We consider capillary condensation transitions occurring in open slits of width L and finite height H immersed in a reservoir of vapor. In this case the pressure at which condensation occurs is closer to saturation compared to that occurring in an infinite slit (H=∞) due to the presence of two menisci that are pinned near the open ends. Using macroscopic arguments, we derive a modified Kelvin equation for the pressure p_{cc}(L;H) at which condensation occurs and show that the two menisci are characterized by an edge contact angle θ_{e} that is always larger than the equilibrium contact angle θ, only equal to it in the limit of macroscopic H. For walls that are completely wet (θ=0) the edge contact angle depends only on the aspect ratio of the capillary and is well described by θ_{e}≈sqrt[πL/2H] for large H. Similar results apply for condensation in cylindrical pores of finite length. We test these predictions against numerical results obtained using a microscopic density-functional model where the presence of an edge contact angle characterizing the shape of the menisci is clearly visible from the density profiles. Below the wetting temperature T_{w} we find very good agreement for slit pores of widths of just a few tens of molecular diameters, while above T_{w} the modified Kelvin equation only becomes accurate for much larger systems.

  5. Acetabular overcoverage in the horizontal plane: an underdiagnosed trigger of early hip arthritis. A CT scan study in young adults.

    PubMed

    Valera, Màrius; Ibáñez, Natalia; Sancho, Rogelio; Llauger, Jaume; Gich, Ignasi

    2018-01-01

    Acetabular overcoverage promotes hip osteoarthritis causing a pincer-type femoroacetabular impingement. Acetabular coverage in the horizontal plane is usually poorly defined in imaging studies and may be misdiagnosed. The goal of this study was to analyze the role of acetabular overcoverage measured in the frontal plane and in the horizontal plane by CT scan and to determine its relationship with other anatomic features in the onset of hip arthritis in young adults. We compared prospectively CT scans from two groups of adults of 55 years or younger: the patient group (n = 30) consisted of subjects with diagnosis of early hip arthritis (Tönnis Grade I or II) and the control group (n = 31) consisted of subjects with healthy hips. Two independent observers analyzed centre edge angle (CEA), acetabular anteversion angle (AAA), anterior sector acetabular angle (AASA), posterior sector acetabular angle (PASA), horizontal acetabular sector angle (HASA), femoral anteversion angle (FAVA), alpha angle (AA), and Mckibbin Instability Index (MI). Angles measuring the acetabular coverage on the horizontal plane (AASA, PASA and, HASA) were significantly higher in the patient group (p < 0.001, p = 0.03 and p < 0.001, respectively). Pearson's correlation coefficient showed a positive correlation between CEA and HASA in patients (r = 0.628) and in controls (r = 0.660). However, a high CEA (> 35º) was strongly associated with a high HASA (> 160º) in patients (p = 0.024) but not in controls (p = 0.21), suggesting that pincer should be simultaneously present in the horizontal and frontal plane to trigger hip degeneration. No significant association was detected between a high alpha angle (> 60º) and a high CEA (> 35º suggesting that a mixed pincer-cam aetiology was not prevalent in our series. Multivariate regression analysis showed the most significant predictors of degenerative joint disease were HASA (p = 0.008), AA (p = 0.048) and ASAA (p = 0.004). Acetabular overcoverage in the horizontal plane plays an important role in the onset of early hip arthritis. Considering that this condition is usually underdiagnosed, we suggest the anterior sector acetabular angle, the posterior sector acetabular angle, and the horizontal acetabular sector angles be routinely included in decision-making algorithms in hip conservative surgery to better define hips-at-risk of developing early hip osteoarthritis.

  6. [The effectiveness of endonasal electrophoresis of neuroprotective agents used in the rehabilitative treatment of the patients presenting with primary open angle glaucoma].

    PubMed

    Nazarova, G A; Konchugova, T V; Iurova, O V; Sichinava, N V; Turova, E A; Rassulova, M A; Morozova, N E

    2013-01-01

    The objective of the present study was to estimate the effectiveness of the peptide drug cortexin used to treat primary open angle glaucoma. It was shown that endonasal electrophoresis of cortexin resulted in more pronounced positive changes in the dynamics of clinical, functional, perimetric, and electrophysiological characteristics compared with intramuscular administration of the same drug to the patients of the control group. This difference was apparent both immediately after the termination of the treatment and during the long-term follow-up.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yanagawa, T.; Sakagami, H.; Nagatomo, H.

    In inertial confinement fusion, the implosion process is important in forming a high-density plasma core. In the case of a fast ignition scheme using a cone-guided target, the fuel target is imploded with a cone inserted. This scheme is advantageous for efficiently heating the imploded fuel core; however, asymmetric implosion is essentially inevitable. Moreover, the effect of cone position and opening angle on implosion also becomes critical. Focusing on these problems, the effect of the asymmetric implosion, the initial position, and the opening angle on the compression rate of the fuel is investigated using a three-dimensional pure hydrodynamic code.

  8. Intrasylvian/Intracerebral Hematomas Associated with Ruptured Middle Cerebral Artery Aneurysms: A Single-Center Series and Literature Review.

    PubMed

    Zhang, Yupeng; Hu, Quan; Xue, Hao; Zhang, Mingran; Shen, Jie; Deng, Lin; Liu, Qinglin; Li, Gang

    2017-02-01

    Ruptured middle cerebral artery (MCA) aneurysms usually lead to subarachnoid hemorrhage (SAH), and several cases have shown concomitant intrasylvian or intracerebral hematomas. The objective of this study was to compare the clinical and radiographic characteristics with their different outcomes. The charts of 30 consecutive patients with ruptured MCA aneurysm-related intracranial hematoma were retrospectively reviewed. These patients were dichotomized into an intrasylvian hematoma (ISH) group and an intracerebral hematoma (ICH) group by the presence of intrahematomal contrast-enhancing vessel; for patients under open surgery, hematoma type was further confirmed by intraoperative observation. The characteristics were compared between these 2 groups (ie, age, gender, history of hypertension, history of smoking, systolic pressure at admission, hematoma volume, size and side of aneurysms, the angle between the pointing direction of the aneurysm and the MCA trunk [denoted as α], middle line shifting, treatment modality, and outcome). All the angles are measured in the anterior-posterior projection. In our series, only hematoma volume, the angle α, and the middle line shift showed statistical significance regarding prognosis between 2 hematoma groups. An angle α between 109.0°and 216.0° is associated with ISH, whereas aneurysm with an angle beyond this range indicates ICH. In our series, patients in the ICH group had a larger hematoma volume compared with the ISH patients (33.3 ± 17.6 vs. 11.5 ± 10.5; P = 0.002). There exists no statistical difference regarding prognosis between these 2 groups, even although there is a trend toward worse recovery for patients in the ISH group (Glasgow Outcome Scale score, 3.0 ± 1.3 vs. 3.8 ± 1.9; P = 0.07). In our series, the prognosis of patients with ICH was worse than that of patients with ISH. Early discrimination of these 2 types of hematoma helps to predict future outcome; an angle (between the pointing direction of aneurysm and the MCA trunk) between 109.0°and 216.0° is associated with ISH, whereas aneurysm with an angle beyond this range suggests ICH. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Argon laser peripheral iridoplasty for angle-closure glaucoma in sibilings with weill-marchesani syndrome.

    PubMed

    Ritch, R; Solomon, L D

    1992-01-01

    A patient with Weill-Marchesani syndrome and angle-closure glaucoma had persistent appositional closure after laser iridotomy that was unrelieved by topical application of either miotic or cycloplegic agents. Argon laser peripheral iridoplasty successfully opened the angle. The patient's sister also had Weill-Marchesani syndrome and angle closure unrelieved by laser iridotomy. Angle closure in Weill-Marchesani syndrome and the response to laser iridotomy and treatment with either miotic or cycloplegic agents may be complex and depends on the relative proportion of pupillary block as a mechanism underlying the angle closure, the functional status of the zonular apparatus, and the degree of angle crowding by the peripheral iris in the presence or absence of peripheral anterior synechiae.

  10. Equilibrium configurations of the conducting liquid surface in a nonuniform electric field

    NASA Astrophysics Data System (ADS)

    Zubarev, N. M.; Zubareva, O. V.

    2011-01-01

    Possible equilibrium configurations of the free surface of a conducting liquid deformed by a nonuniform external electric field are investigated. The liquid rests on an electrode that has the shape of a dihedral angle formed by two intersecting equipotential half-planes (conducting wedge). It is assumed that the problem has plane symmetry: the surface is invariant under shift along the edge of the dihedral angle. A one-parametric family of exact solutions for the shape of the surface is found in which the opening angle of the region above the wedge serves as a parameter. The solutions are valid when the pressure difference between the inside and outside of the liquid is zero. For an arbitrary pressure difference, approximate solutions to the problem are constructed and it is demonstrated the approximation error is small. It is found that, when the potential difference exceeds a certain threshold value, equilibrium solutions are absent. In this case, the region occupied by the liquid disintegrates, the disintegration scenario depending on the opening angle.

  11. Numerical investigation of the early flight phase in ski-jumping.

    PubMed

    Gardan, N; Schneider, A; Polidori, G; Trenchard, H; Seigneur, J M; Beaumont, F; Fourchet, F; Taiar, R

    2017-07-05

    The purpose of this study is to develop a numerical methodology based on real data from wind tunnel experiments to investigate the effect of the ski jumper's posture and speed on aerodynamic forces in a wide range of angles of attack. To improve our knowledge of the aerodynamic behavior of the ski jumper and his equipment during the early flight phase of the ski jump, we applied CFD methodology to evaluate the influence of angle of attack (α=14°, 21.5°, 29°, 36.5° and 44°) and speed (u=23, 26 and 29m/s) on aerodynamic forces in the situation of stable attitude of the ski jumper's body and skis. The standard k-ω turbulence model was used to investigate both the influence of the ski jumper's posture and speed on aerodynamic performance during the early flight phase. Numerical results show that the ski jumper's speed has very little impact on the lift and drag coefficients. Conversely, the lift and drag forces acting on the ski jumper's body during the early flight phase of the jump are strongly influenced by the variations of the angle of attack. The present results suggest that the greater the ski jumper's angle of inclination, with respect to the relative flow, the greater the pressure difference between the lower and upper parts of the skier. Further studies will focus on the dependency of the parameters with both the angle of attack α and the body-ski angle β as control variables. It will be possible to test and optimize different ski jumping styles in different ski jumping hills and investigate different environmental conditions such as temperature, altitude or crosswinds. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Early Changes in Facial Profile Following Structured Filler Rhinoplasty: An Anthropometric Analysis Using a 3-Dimensional Imaging System.

    PubMed

    Rho, Nark Kyoung; Park, Je Young; Youn, Choon Shik; Lee, Soo-Keun; Kim, Hei Sung

    2017-02-01

    Quantitative measurements are important for objective evaluation of postprocedural outcomes. Three-dimensional (3D) imaging is known as an objective, accurate, and reliable system for quantifying the soft tissue dimensions of the face. To compare the preprocedural and acute postprocedural nasofrontal, nasofacial, nasolabial, and nasomental angles, early changes in the height and length of the nose, and nasal volume using a 3D surface imaging with a light-emitting diode. The 3D imaging analysis of 40 Korean women who underwent structured nonsurgical rhinoplasty was conducted. The 3D assessment was performed before, immediately after, 1 day, and 2 weeks after filler rhinoplasty with a Morpheus 3D scanner (Morpheus Co., Seoul, Korea). There were significant early changes in facial profile following nonsurgical rhinoplasty with a hyaluronic acid filler. An average increase of 6.03° in the nasofrontal angle, an increase of 3.79° in the nasolabial angle, increase of 0.88° in the nasomental angle, and a reduction of 0.83° in the nasofacial angle was observed at 2 weeks of follow-up. Increment in nasal volume and nose height was also found after 2 weeks. Side effects, such as hematoma, nodules, and skin necrosis, were not observed. The 3D surface imaging quantitatively demonstrated the early changes in facial profile after structured filler rhinoplasty. The study results describe significant acute spatial changes in nose shape following treatment.

  13. Gamma-Ray Burst Jet Breaks Revisited

    NASA Astrophysics Data System (ADS)

    Wang, Xiang-Gao; Zhang, Bing; Liang, En-Wei; Lu, Rui-Jing; Lin, Da-Bin; Li, Jing; Li, Long

    2018-06-01

    Gamma-ray Burst (GRB) collimation has been inferred with the observations of achromatic steepening in GRB light curves, known as jet breaks. Identifying a jet break from a GRB afterglow light curve allows a measurement of the jet opening angle and true energetics of GRBs. In this paper, we re-investigate this problem using a large sample of GRBs that have an optical jet break that is consistent with being achromatic in the X-ray band. Our sample includes 99 GRBs from 1997 February to 2015 March that have optical and, for Swift GRBs, X-ray light curves that are consistent with the jet break interpretation. Out of the 99 GRBs we have studied, 55 GRBs are found to have temporal and spectral behaviors both before and after the break, consistent with the theoretical predictions of the jet break models, respectively. These include 53 long/soft (Type II) and 2 short/hard (Type I) GRBs. Only 1 GRB is classified as the candidate of a jet break with energy injection. Another 41 and 3 GRBs are classified as the candidates with the lower and upper limits of the jet break time, respectively. Most jet breaks occur at 90 ks, with a typical opening angle θj = (2.5 ± 1.0)°. This gives a typical beaming correction factor {f}b-1∼ 1000 for Type II GRBs, suggesting an even higher total GRB event rate density in the universe. Both isotropic and jet-corrected energies have a wide span in their distributions: log(Eγ,iso/erg) = 53.11 with σ = 0.84 log(EK,iso/erg) = 54.82 with σ = 0.56 log(Eγ/erg) = 49.54 with σ = 1.29 and log(EK/erg) = 51.33 with σ = 0.58. We also investigate several empirical correlations (Amati, Frail, Ghirlanda, and Liang–Zhang) previously discussed in the literature. We find that in general most of these relations are less tight than before. The existence of early jet breaks and hence small opening angle jets, which were detected in the Swfit era, is most likely the source of scatter. If one limits the sample to jet breaks later than 104 s, the Liang–Zhang relation remains tight and the Ghirlanda relation still exists. These relations are derived from Type II GRBs, and Type I GRBs usually deviate from them.

  14. Comparison of the diagnostic ability of Moorfield’s regression analysis and glaucoma probability score using Heidelberg retinal tomograph III in eyes with primary open angle glaucoma

    PubMed Central

    Jindal, Shveta; Dada, Tanuj; Sreenivas, V; Gupta, Viney; Sihota, Ramanjit; Panda, Anita

    2010-01-01

    Purpose: To compare the diagnostic performance of the Heidelberg retinal tomograph (HRT) glaucoma probability score (GPS) with that of Moorfield’s regression analysis (MRA). Materials and Methods: The study included 50 eyes of normal subjects and 50 eyes of subjects with early-to-moderate primary open angle glaucoma. Images were obtained by using HRT version 3.0. Results: The agreement coefficient (weighted k) for the overall MRA and GPS classification was 0.216 (95% CI: 0.119 – 0.315). The sensitivity and specificity were evaluated using the most specific (borderline results included as test negatives) and least specific criteria (borderline results included as test positives). The MRA sensitivity and specificity were 30.61 and 98% (most specific) and 57.14 and 98% (least specific). The GPS sensitivity and specificity were 81.63 and 73.47% (most specific) and 95.92 and 34.69% (least specific). The MRA gave a higher positive likelihood ratio (28.57 vs. 3.08) and the GPS gave a higher negative likelihood ratio (0.25 vs. 0.44).The sensitivity increased with increasing disc size for both MRA and GPS. Conclusions: There was a poor agreement between the overall MRA and GPS classifications. GPS tended to have higher sensitivities, lower specificities, and lower likelihood ratios than the MRA. The disc size should be taken into consideration when interpreting the results of HRT, as both the GPS and MRA showed decreased sensitivity for smaller discs and the GPS showed decreased specificity for larger discs. PMID:20952832

  15. Retinal adaptation abnormalities in primary open-angle glaucoma.

    PubMed

    Dul, Mitchell; Ennis, Robert; Radner, Shira; Lee, Barry; Zaidi, Qasim

    2015-01-22

    Dynamic color and brightness adaptation are crucial for visual functioning. The effects of glaucoma on retinal ganglion cells (RGCs) could compromise these functions. We have previously used slow dynamic changes of light at moderate intensities to measure the speed and magnitude of subtractive adaptation in RGCs. We used the same procedure to test if RGC abnormalities cause slower and weaker adaptation for patients with glaucoma when compared to age-similar controls. We assessed adaptation deficits in specific classes of RGCs by testing along the three cardinal color axes that isolate konio, parvo, and magno RGCs. For one eye each of 10 primary open-angle glaucoma patients and their age-similar controls, we measured the speed and magnitude of adapting to 1/32 Hz color modulations along the three cardinal axes, at central fixation and 8° superior, inferior, nasal, and temporal to fixation. In all 15 comparisons (5 locations × 3 color axes), average adaptation was slower and weaker for glaucoma patients than for controls. Adaptation developed slower at central targets than at 8° eccentricities for controls, but not for patients. Adaptation speed and magnitude differed between affected and control eyes even at retinal locations showing no visual field loss with clinical perimetry. Neural adaptation is weaker in glaucoma patients for all three classes of RGCs. Since adaptation abnormalities are manifested even at retinal locations not exhibiting a visual field loss, this novel form of assessment may offer a functional insight into glaucoma and an early diagnosis tool. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  16. Quality of Life in Glaucoma: A Review of the Literature.

    PubMed

    Quaranta, Luciano; Riva, Ivano; Gerardi, Chiara; Oddone, Francesco; Floriano, Irene; Konstas, Anastasios G P

    2016-06-01

    The ultimate goal of glaucoma management is the preservation of patients' visual function and quality of life (QoL). The disease itself as well as the medical or surgical treatment can have an enormous impact on a patient's QoL. Even the mere diagnosis of a chronic, irreversible, potentially blinding disorder can adversely affect the patient's sense of well-being and QoL by eliciting significant anxiety. Patients with primary open-angle glaucoma rarely present with visual symptoms, at least early in the course of the disease. A better understanding of patient-reported QoL can improve patient-physician interaction and enhance treatment adherence by customizing treatment options based on individual patient profile, thus optimizing long-term prognosis. These aspects are summarized and critically appraised in this article.

  17. Five-year results after valve replacement with the Björk-Shiley 70 degrees convexo-concave prosthesis.

    PubMed

    Koldsland, S; Svennevig, J L; Abdelnoor, M; Aas, H; Semb, G

    1992-01-01

    In the 18 months up to July 1983, 120 Björk-Shiley convexo-concave prostheses with 70 degrees opening angle were implanted in 47 women and 61 men aged 19-78 (mean 58.6) years. The prosthetic valves were aortic in 65 cases, mitral in 23 and both aortic and mitral in 20 cases. Emergency operation was required in ten cases, and concomitant surgery was performed in 43 (39.8%). The early mortality was 5.5%. A follow-up study, comprising 498 patient years, revealed 73.1% 5-year survival. There were three mechanical failures of prosthesis, in one of which re-replacement was successful. Elective prosthesis replacement was performed in four other cases judged to be at high risk of strut fracture.

  18. Comparison of the cable pin system with conventional open surgery for transverse patella fractures.

    PubMed

    Mao, Ningfang; Liu, Deding; Ni, Haijian; Tang, Hao; Zhang, Qiulin

    2013-07-01

    The cable pin system is an effective device for fixation of transverse patella fractures. However, whether this device provides superior results using a minimally invasive technique instead of conventional open surgery using the K wire tension band method is unclear. We asked whether a minimally invasive technique would be associated with (1) increased operative time; (2) reduced postoperative pain; (3) faster recovery of ROM; (4) higher knee scores; and (5) reduced complications. Forty patients with displaced transverse fractures of the patella participated in this prospective, randomized, controlled trial. Twenty of these patients underwent a minimally invasive technique and the others had conventional open surgery using K wires. Some data for six of the 20 patients who underwent the minimally invasive technique were published in an earlier prospective, observational trial. At postoperative intervals of 1, 3, 6, 12, and 24 months, pain was measured by VAS scores, active flexion and extension of the knee were measured in degrees by goniometry, and knee function was evaluated using the Böstman clinical grading scale. Operative time was longer in the minimally invasive surgery group (54.3 ± 9.8 minutes versus 48.5 ± 6.1 minutes). Pain scores were better (lower) in the minimally invasive surgery group at 1 and 3 months but not at 6 months. Early flexion, ultimate flexion, and knee scores from 3 to 24 months, likewise, were better in the minimally invasive surgery group. Complications mostly related to symptomatic hardware were less common in the minimally invasive surgery group. The minimally invasive technique is superior to conventional open surgery using K wires in terms of less early postoperative pain, better mobility angles of the injured knee, higher functional score of the injured knee, and decreased incidence of complications. Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  19. Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes.

    PubMed

    Nolan, Winifred P; See, Jovina L; Chew, Paul T K; Friedman, David S; Smith, Scott D; Radhakrishnan, Sunita; Zheng, Ce; Foster, Paul J; Aung, Tin

    2007-01-01

    To evaluate noncontact anterior segment optical coherence technology (AS-OCT) as a qualitative method of imaging the anterior chamber angle and to determine its ability to detect primary angle closure when compared with gonioscopy in Asian subjects. Prospective observational case series. Two hundred three subjects were recruited from glaucoma clinics in Singapore with diagnoses of primary angle closure, primary open-angle glaucoma, ocular hypertension, or cataract. Both eyes (if eligible) of each patient were included in the study. Exclusion criteria were pseudophakia or previous glaucoma surgery. Images of the nasal, temporal, and inferior angles were obtained with AS-OCT in dark and then light conditions. Gonioscopic angle width was graded using the Spaeth classification for each quadrant in low lighting conditions. Angle closure was defined by AS-OCT as contact between the peripheral iris and angle wall anterior to the scleral spur and by gonioscopy as a Spaeth grade of 0 degree (posterior trabecular meshwork not visible). Comparison of the 2 methods in detecting angle closure was done by eye and by individual. Sensitivities and specificities of AS-OCT were calculated using gonioscopy as the reference standard. Complete data were available for 342 eyes of 200 patients. Of the patients, 70.9% had a clinical diagnosis of treated or untreated primary angle closure. Angle closure in > or =1 quadrants was detected by AS-OCT in 142 (71%) patients (228 [66.7%] eyes) and by gonioscopy in 99 (49.5%) patients (152 [44.4%] eyes). The inferior angle was closed more frequently than the nasal or temporal quadrants using both AS-OCT and gonioscopy. When performed under dark conditions, AS-OCT identified 98% of those subjects found to have angle closure on gonioscopy (95% confidence interval [CI], 92.2-99.6) and led to the characterization of 44.6% of those found to have open angles on gonioscopy to have angle closure as well. With gonioscopy as the reference standard, specificity of AS-OCT in the dark was 55.4% (95% CI, 45.2-65.2) for detecting individuals with angle closure. Anterior segment OCT is a rapid noncontact method of imaging angle structures. It is highly sensitive in detecting angle closure when compared with gonioscopy. More persons are found to have closed angles with AS-OCT than with gonioscopy.

  20. Ocular Pseudoexfoliation and Cardiovascular Disease: A National Cross-Section Comparison Study

    PubMed Central

    French, Dustin D; Margo, Curtis E; Harman, Lynn E

    2012-01-01

    Background: Pseudoexfoliation is a systemic disorder characterized by the deposition of extracellular matrix material. The microfibrillar material that gives rise to the condition is visible clinically in the anterior segment of the eye, and is also found in other tissues, including blood vessels, skin, gallbladder, kidneys, lungs, and heart. Aims: The present study aims to determine whether ocular pseudoexfoliation is associated with selected cardiovascular diseases. Materials and Methods: A cross-section comparison study was conducted with the help of the Veterans Health Administration databases, using the International Classification of Diseases, Ninth revision, Clinical Modification for pseudoexfoliation of lens capsule and pseudoexfoliation glaucoma. Selected cardiovascular diseases and risk factors for cardiovascular disease were identified using the appropriate medical codes. Patients with primary open-angle glaucoma, chronic sinusitis, and benign prostatic hyperplasia served as the comparison groups. A logistic regression model was used to control for age, gender, race, and major cardiovascular risk factors. Results: There were 6,046 case patients with pseudoexfoliation; approximately half were diagnosed with pseudoexfoliation glaucoma. Various stages of ischemic heart disease, cardiomyopathy, and aortic aneurysm were significantly associated with ocular pseudoexfoliation, after controlling for age, gender, race, and major cardiovascular risk factors. Associations, in general, were less demonstrable relative to the primary open-angle glaucoma comparison group. Conclusion: Associations of ocular pseudoexfoliation with cardiovascular diseases were generally fewer and less pronounced when compared to patients with primary open-angle glaucoma. These results add to the results of earlier studies, which suggest that open-angle glaucoma itself might be a risk factor for certain cardiovascular disorders. PMID:23112968

  1. Comparison between visual field defect in pigmentary glaucoma and primary open-angle glaucoma.

    PubMed

    Nilforushan, Naveed; Yadgari, Maryam; Jazayeri, Anisalsadat

    2016-10-01

    To compare visual field defect patterns between pigmentary glaucoma and primary open-angle glaucoma. Retrospective, comparative study. Patients with diagnosis of primary open-angle glaucoma (POAG) and pigmentary glaucoma (PG) in mild to moderate stages were enrolled in this study. Each of the 52 point locations in total and pattern deviation plot (excluding 2 points adjacent to blind spot) of 24-2 Humphrey visual field as well as six predetermined sectors were compared using SPSS software version 20. Comparisons between 2 groups were performed with the Student t test for continuous variables and the Chi-square test for categorical variables. Thirty-eight eyes of 24 patients with a mean age of 66.26 ± 11 years (range 48-81 years) in the POAG group and 36 eyes of 22 patients with a mean age of 50.52 ± 11 years (range 36-69 years) in the PG group were studied. (P = 0.00). More deviation was detected in points 1, 3, 4, and 32 in total deviation (P = 0.03, P = 0.015, P = 0.018, P = 0.023) and in points 3, 4, and 32 in pattern deviation (P = 0.015, P = 0.049, P = 0.030) in the POAG group, which are the temporal parts of the field. It seems that the temporal area of the visual field in primary open-angle glaucoma is more susceptible to damage in comparison with pigmentary glaucoma.

  2. Macular Thickness Variability in Primary Open Angle Glaucoma Patients using Optical Coherence Tomography

    PubMed Central

    Agarwal, Prakashchand; Sathyan, P; Saini, VK

    2014-01-01

    ABSTRACT Aim: To compare the difference of retinal macular thickness and macular volume using optical coherence tomography (OCT) in primary open angle glaucoma (POAG) patients with the normal subjects. Materials and methods: This observational case control study included primary open angle glaucoma (POAG) patients (n = 124 eyes) and healthy subjects in the control group (n = 124 eyes). All subjects underwent detailed history, general and systemic exami -nation. Complete ocular examination included best corrected visual acuity (BCVA), slit lamp examination, intraocular pressure (IOP), central corneal thickness, gonioscopy, dilated fundus biomicroscopy. Field analysis was done by white on white Humphrey Field Analyzer (Carl Zeiss). Optical coherence tomography imaging of macular area was performed using Stratus OCT (OCT 3, Version 4, Carl Zeiss Inc, Dublin, California, USA). In both these groups, parameters analyzed were macular thickness, inner macular thicknesses (IMT), outer macular thicknesses (OMT), central macular thick ness (CMT) and total macular volume (TMV). Results: The POAG group had significantly decreased values of TMV, OMT and IMT, compared to control group, while there was no difference in CMT, presumably due to absence of ganglion cells in the central part. Thus, macular thickness and volume parameters may be used for making the diagnosis of glaucoma especially in patients with abnormalities of disc. Conclusion: Macular thickness parameters correlated well with the diagnosis of glaucoma. How to cite this article: Sharma A, Agarwal P, Sathyan P, Saini VK. Macular Thickness Variability in Primary Open Angle Glaucoma Patients using Optical Coherence Tomography. J Current Glau Prac 2014;8(1):10-14. PMID:26997801

  3. Glymphatic stasis at the site of the lamina cribrosa as a potential mechanism underlying open-angle glaucoma.

    PubMed

    Wostyn, Peter; Killer, Hanspeter Esriel; De Deyn, Peter Paul

    2017-07-01

    The underlying pathophysiology of primary open-angle glaucoma remains unclear, but the lamina cribrosa seems to be the primary site of injury, and raised intraocular pressure is a major risk factor. In recent years, a decreased intracranial pressure, leading to an abnormally high trans-lamina cribrosa pressure difference, has gained interest as a new risk factor for glaucoma. New research now lends support to the hypothesis that a paravascular transport system is present in the eye analogous to the recently discovered 'glymphatic system' in the brain, which is a functional waste clearance pathway that promotes elimination of interstitial solutes, including β-amyloid, from the brain along paravascular channels. Given that β-amyloid has been reported to increase by chronic elevation of intraocular pressure in glaucomatous animal models and to cause retinal ganglion cell death, the discovery of a paravascular clearance system in the eye may provide powerful new insights into the pathophysiology of primary open-angle glaucoma. In this review, we provide a new conceptual framework for understanding the pathogenesis of primary open-angle glaucoma, present supporting preliminary data from our own post-mortem study and hypothesize that the disease may result from restriction of normal glymphatic flow at the level of the lamina cribrosa owing to a low intracranial pressure and/or a high trans-lamina cribrosa pressure gradient. If confirmed, this viewpoint could offer new perspectives for the development of novel diagnostic and therapeutic strategies for this devastating disorder. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  4. Reliable early opening strength for concrete pavements and patch work

    DOT National Transportation Integrated Search

    2016-06-01

    Early opening strengths for concrete vary greatly around the country for many different reasons. DOTD specifies early opening strengths and will benefit from understanding the latest thinking and practices adopted by similar agencies. Knowing the bes...

  5. Numerical exploration of non-axisymmetric divertor closure in the small angle slot (SAS) divertor at DIII-D

    NASA Astrophysics Data System (ADS)

    Frerichs, Heinke; Schmitz, Oliver; Covele, Brent; Guo, Houyang; Hill, David; Feng, Yuhe

    2017-10-01

    In the Small Angle Slot (SAS) divertor in DIII-D, the combination of misaligned slot structure and non-axisymmetric perturbations to the magnetic field causes the strike point to vary radially along the divertor slot and even leave it at some toroidal locations. This effect essentially introduces an opening in the divertor slot from where recycling neutrals can easily escape, and thereby degrade performance of the slot divertor. This effect has been approximated by a finite gap in the divertor baffle. Simulations with EMC3-EIRENE show that a toroidally localized loss of divertor closure can result in non-axisymmetric divertor densities and temperatures. This introduces a density window of 10-15% on top of the nominal threshold separatrix density during which a non-axisymmetric onset of local detachment occurs, initially leaving the gap and up to 60 deg beyond that still attached. Conversely, the impact of such toroidally localized divertor perturbations on the toroidal symmetry of midplane separatrix conditions is small. This work has been funded by the U.S. Department of Energy under Early Career Award Grant DE-SC0013911, and Grant DE-FC02-04ER54698.

  6. The directivity of the sound radiation from panels and openings.

    PubMed

    Davy, John L

    2009-06-01

    This paper presents a method for calculating the directivity of the radiation of sound from a panel or opening, whose vibration is forced by the incidence of sound from the other side. The directivity of the radiation depends on the angular distribution of the incident sound energy in the room or duct in whose wall or end the panel or opening occurs. The angular distribution of the incident sound energy is predicted using a model which depends on the sound absorption coefficient of the room or duct surfaces. If the sound source is situated in the room or duct, the sound absorption coefficient model is used in conjunction with a model for the directivity of the sound source. For angles of radiation approaching 90 degrees to the normal to the panel or opening, the effect of the diffraction by the panel or opening, or by the finite baffle in which the panel or opening is mounted, is included. A simple empirical model is developed to predict the diffraction of sound into the shadow zone when the angle of radiation is greater than 90 degrees to the normal to the panel or opening. The method is compared with published experimental results.

  7. A Microbeam Small-Angle X-ray Scattering Study on Enamel Crystallites in Subsurface Lesion

    NASA Astrophysics Data System (ADS)

    Yagi, N.; Ohta, N.; Matsuo, T.; Tanaka, T.; Terada, Y.; Kamasaka, H.; Kometani, T.

    2010-10-01

    The early caries lesion in bovine tooth enamel was studied by two different X-ray diffraction systems at the SPring-8 third generation synchrotron radiation facility. Both allowed us simultaneous measurement of the small and large angle regions. The beam size was 6μm at BL40XU and 50μm at BL45XU. The small-angle scattering from voids in the hydroxyapatite crystallites and the wide-angle diffraction from the hydroxyapatite crystals were observed simultaneously. At BL40XU an X-ray image intensifier was used for the small-angle and a CMOS flatpanel detector for the large-angle region. At BL45XU, a large-area CCD detector was used to cover both regions. A linear microbeam scan at BL40XU showed a detailed distribution of voids and crystals and made it possible to examine the structural details in the lesion. The two-dimensional scan at BL45XU showed distribution of voids and crystals in a wider region in the enamel. The simultaneous small- and wide-angle measurement with a microbeam is a powerful tool to elucidate the mechanisms of demineralization and remineralization in the early caries lesion.

  8. An Experimental Investigation on the Generation of a Stable Arch in Granular Materials Using a Developed Trapdoor Apparatus

    NASA Astrophysics Data System (ADS)

    Ahmadi, Ali; Seyedi Hosseininia, Ehsan

    2017-06-01

    This paper discusses the formation of stable arches in granular materials by using a series of laboratory tests. To this aim, a developed trapdoor apparatus is designed to find dimensions of arches formed over the door in cohesionless aggregates. This setup has two new important applications. In order to investigate the maximum width of the opening generated exactly on the verge of failure, the door can be open to an arbitrary size. In addition, the box containing granular materials (or base angle) is able to be set on optional angles from zero to 90 degrees with respect to the horizontal. Therefore, it is possible to understand the effect of different levels of gravity accelerations on the formed arches. It is observed that for all tested granular materials, increasing the door size and decreasing the base angle, both cause to increase the width and height of the arch. Moreover, the shape of all arches is governed by a parabola. Furthermore, the maximum door width is approximately five to 8.6 times the particle size, depending on the internal friction angle of materials and the base angle.

  9. Establishing Age-Adjusted Reference Ranges for Iris-Related Parameters in Open Angle Eyes with Anterior Segment Optical Coherence Tomography

    PubMed Central

    Peterson, Jeffrey R.; Blieden, Lauren S.; Chuang, Alice Z.; Baker, Laura A.; Rigi, Mohammed; Feldman, Robert M.; Bell, Nicholas P.

    2016-01-01

    Purpose Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT). Methods Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18–35, 36–45, 46–55, 56–65, and 66–79 years). ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan) and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL), length of scleral spur landmark (SSL) to pupillary margin (SSL-to-PM), iris contour ratio (ICR = AISL/SSL-to-PM), pupil radius, radius of iris centroid (RICe), and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter. Results Mean (±SD) values were 2.24 mm (±0.46), 4.06 mm (±0.27), 3.65 mm (±0.48), 4.16 mm (±0.47), 1.14 (±0.04), 1.51 mm2 (±0.23), and 38.42 μL (±4.91) for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002) and RICe (P = 0.027) decreased with age, while SSL-to-PM (P = 0.002) and AISL increased with age (P = 0.001). ICR (P = 0.54) and iris volume (P = 0.49) were not affected by age. Conclusion This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states. PMID:26815917

  10. Establishing Age-Adjusted Reference Ranges for Iris-Related Parameters in Open Angle Eyes with Anterior Segment Optical Coherence Tomography.

    PubMed

    Peterson, Jeffrey R; Blieden, Lauren S; Chuang, Alice Z; Baker, Laura A; Rigi, Mohammed; Feldman, Robert M; Bell, Nicholas P

    2016-01-01

    Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT). Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18-35, 36-45, 46-55, 56-65, and 66-79 years). ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan) and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL), length of scleral spur landmark (SSL) to pupillary margin (SSL-to-PM), iris contour ratio (ICR = AISL/SSL-to-PM), pupil radius, radius of iris centroid (RICe), and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter. Mean (±SD) values were 2.24 mm (±0.46), 4.06 mm (±0.27), 3.65 mm (±0.48), 4.16 mm (±0.47), 1.14 (±0.04), 1.51 mm2 (±0.23), and 38.42 μL (±4.91) for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002) and RICe (P = 0.027) decreased with age, while SSL-to-PM (P = 0.002) and AISL increased with age (P = 0.001). ICR (P = 0.54) and iris volume (P = 0.49) were not affected by age. This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states.

  11. Graft Angle its Relationship to Tomato Plant Survival

    USDA-ARS?s Scientific Manuscript database

    Growing plants that can withstand the rigors of open field production is imperative. This study examines the relationship of tensile strength to graft angle and plant survival. Tomato seedlings of ‘FL47’ and ‘Rutgers’ were used as scions on ‘Roma’ rootstock under greenhouse and healing chamber con...

  12. Hydraulic droplet coarsening in open-channel capillaries

    NASA Astrophysics Data System (ADS)

    Warren, Patrick B.

    2016-11-01

    Over a range of liquid-solid contact angles, an open-channel capillary with curved or angled sides can show a maximum in the Laplace pressure as a function of the filling state. Examples include double-angle wedges, grooves scored into flat surfaces, steps on surfaces, and the groove between touching parallel cylinders. The liquid in such a channel exhibits a beading instability if the channel is filled beyond the Laplace pressure maximum. The subsequent droplet coarsening takes place by hydraulic transport through the connecting liquid columns that remain in the groove. A mean-field scaling argument predicts the characteristic droplet radius R ˜t1 /7 , as a function of time t . This is confirmed by one-dimensional simulations of the coarsening kinetics. Some remarks are also made on the spreading kinetics of an isolated drop deposited in such a channel.

  13. The Research of the Parallel Computing Development from the Angle of Cloud Computing

    NASA Astrophysics Data System (ADS)

    Peng, Zhensheng; Gong, Qingge; Duan, Yanyu; Wang, Yun

    2017-10-01

    Cloud computing is the development of parallel computing, distributed computing and grid computing. The development of cloud computing makes parallel computing come into people’s lives. Firstly, this paper expounds the concept of cloud computing and introduces two several traditional parallel programming model. Secondly, it analyzes and studies the principles, advantages and disadvantages of OpenMP, MPI and Map Reduce respectively. Finally, it takes MPI, OpenMP models compared to Map Reduce from the angle of cloud computing. The results of this paper are intended to provide a reference for the development of parallel computing.

  14. Measurement of surface tension and viscosity by open capillary techniques

    DOEpatents

    Rye,Robert R. , Yost,Frederick G.

    1998-01-01

    An open-channel capillary is provided, having preferably a v-shaped groove in a flat wettable surface. The groove has timing marks and a source marker in which the specimen to be tested is deposited. The time of passage between the timing marks is recorded, and the ratio of surface tension .gamma. to viscosity .mu. is determined from the equation given below: ##EQU1## where h.sub.0 is the groove depth, .alpha. is the groove angle, .theta. is the liquid/solid contact angle, and t is the flow time. It has been shown by the

  15. The Use of Sun Elevation Angle for Stereogrammetric Boreal Forest Height in Open Canopies

    NASA Technical Reports Server (NTRS)

    Montesano, Paul M.; Neigh, Christopher; Sun, Guoqing; Duncanson, Laura Innice; Van Den Hoek, Jamon; Ranson, Kenneth Jon

    2017-01-01

    Stereogrammetry applied to globally available high resolution spaceborne imagery (HRSI; less than 5 m spatial resolution) yields fine-scaled digital surface models (DSMs) of elevation. These DSMs may represent elevations that range from the ground to the vegetation canopy surface, are produced from stereoscopic image pairs (stereo pairs) that have a variety of acquisition characteristics, and have been coupled with lidar data of forest structure and ground surface elevation to examine forest height. This work explores surface elevations from HRSI DSMs derived from two types of acquisitions in open canopy forests. We (1) apply an automated mass-production stereogrammetry workflow to along-track HRSI stereo pairs, (2) identify multiple spatially coincident DSMs whose stereo pairs were acquired under different solar geometry, (3) vertically co-register these DSMs using coincident spaceborne lidar footprints (from ICESat-GLAS) as reference, and(4) examine differences in surface elevations between the reference lidar and the co-registered HRSI DSMs associated with two general types of acquisitions (DSM types) from different sun elevation angles. We find that these DSM types, distinguished by sun elevation angle at the time of stereo pair acquisition, are associated with different surface elevations estimated from automated stereogrammetry in open canopy forests. For DSM values with corresponding reference ground surface elevation from spaceborne lidar footprints in open canopy northern Siberian Larix forests with slopes less than10, our results show that HRSI DSM acquired with sun elevation angles greater than 35deg and less than 25deg (during snow-free conditions) produced characteristic and consistently distinct distributions of elevation differences from reference lidar. The former include DSMs of near-ground surfaces with root mean square errors less than 0.68 m relative to lidar. The latter, particularly those with angles less than 10deg, show distributions with larger differences from lidar that are associated with open canopy forests whose vegetation surface elevations are captured. Terrain aspect did not have a strong effect on the distribution of vegetation surfaces. Using the two DSM types together, the distribution of DSM-differenced heights in forests (6.0 m, sigma = 1.4 m) was consistent with the distribution of plot-level mean tree heights (6.5m, sigma = 1.2 m). We conclude that the variation in sun elevation angle at time of stereo pair acquisition can create illumination conditions conducive for capturing elevations of surfaces either near the ground or associated with vegetation canopy. Knowledge of HRSI acquisition solar geometry and snow cover can be used to understand and combine stereogrammetric surface elevation estimates to co-register rand difference overlapping DSMs, providing a means to map forest height at fine scales, resolving the vertical structure of groups of trees from spaceborne platforms in open canopy forests.

  16. Influence of Contact Angle, Growth Angle and Melt Surface Tension on Detached Solidification of InSb

    NASA Technical Reports Server (NTRS)

    Wang, Yazhen; Regel, Liya L.; Wilcox, William R.

    2000-01-01

    We extended the previous analysis of detached solidification of InSb based on the moving meniscus model. We found that for steady detached solidification to occur in a sealed ampoule in zero gravity, it is necessary for the growth angle to exceed a critical value, the contact angle for the melt on the ampoule wall to exceed a critical value, and the melt-gas surface tension to be below a critical value. These critical values would depend on the material properties and the growth parameters. For the conditions examined here, the sum of the growth angle and the contact angle must exceed approximately 130, which is significantly less than required if both ends of the ampoule are open.

  17. Probing glaucoma visual damage by rarebit perimetry.

    PubMed

    Brusini, P; Salvetat, M L; Parisi, L; Zeppieri, M

    2005-02-01

    To compare rarebit perimetry (RBP) with standard achromatic perimetry (SAP) in detecting early glaucomatous functional damage. 43 patients with ocular hypertension (OH), 39 with early primary open angle glaucoma (POAG), and 41 controls were considered. Visual fields were assessed using the Humphrey field analyser (HFA) 30-2 and RBP tests. Differences among the groups were evaluated using Student-Newman-Keuls and chi(2) tests. Correlation between HFA and RBP parameters was assessed using the Pearson's correlation coefficients and regression analysis. Sensitivity and specificity of RBP in detecting early glaucomatous visual damage were calculated with different algorithms. RBP-mean hit rate (MHR) was respectively 88.6% (SD 4.8%) in controls; 79.1% (10.9%) in the OH group; 64.3% (13.8%) in the POAG group (differences statistically significant). Good correlation in the POAG group was found between HFA-mean deviation and RBP-MHR. Largest AROC (0.95) and optimal sensitivity (97.4%) were obtained when an abnormal RBP test was defined as having (at least 1): MHR <80%; >15 areas with a non-hit rate of >10%; > or =2 areas with a non-hit rate of >50%; at least one area with a non-hit rate of > or =70%. The RBP appeared to be a rapid, comfortable, and easily available perimetric test (requiring only a PC device), showing a high sensitivity and specificity in detecting early glaucomatous visual field defects.

  18. The effect of aortic morphology on peri-operative mortality of ruptured abdominal aortic aneurysm.

    PubMed

    2015-06-01

    To investigate whether aneurysm shape and extent, which indicate whether a patient with ruptured abdominal aortic aneurysm (rAAA) is eligible for endovascular repair (EVAR), influence the outcome of both EVAR and open surgical repair. The influence of six morphological parameters (maximum aortic diameter, aneurysm neck diameter, length and conicality, proximal neck angle, and maximum common iliac diameter) on mortality and reinterventions within 30 days was investigated in rAAA patients randomized before morphological assessment in the Immediate Management of the Patient with Rupture: Open Versus Endovascular strategies (IMPROVE) trial. Patients with a proven diagnosis of rAAA, who underwent repair and had their admission computerized tomography scan submitted to the core laboratory, were included. Among 458 patients (364 men, mean age 76 years), who had either EVAR (n = 177) or open repair (n = 281) started, there were 155 deaths and 88 re-interventions within 30 days of randomization analysed according to a pre-specified plan. The mean maximum aortic diameter was 8.6 cm. There were no substantial correlations between the six morphological variables. Aneurysm neck length was shorter in those undergoing open repair (vs. EVAR). Aneurysm neck length (mean 23.3, SD 16.1 mm) was inversely associated with mortality for open repair and overall: adjusted OR 0.72 (95% CI 0.57, 0.92) for each 16 mm (SD) increase in length. There were no convincing associations of morphological parameters with reinterventions. Short aneurysm necks adversely influence mortality after open repair of rAAA and preclude conventional EVAR. This may help explain why observational studies, but not randomized trials, have shown an early survival benefit for EVAR. ISRCTN 48334791. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  19. LOXL1 deficiency in the lamina cribrosa as candidate susceptibility factor for a pseudoexfoliation-specific risk of glaucoma.

    PubMed

    Schlötzer-Schrehardt, Ursula; Hammer, Christian M; Krysta, Anita W; Hofmann-Rummelt, Carmen; Pasutto, Francesca; Sasaki, Takako; Kruse, Friedrich E; Zenkel, Matthias

    2012-09-01

    To test the hypothesis that a primary disturbance in lysyl oxidase-like 1 (LOXL1) and elastin metabolism in the lamina cribrosa of eyes with pseudoexfoliation syndrome constitutes an independent risk factor for glaucoma development and progression. Observational, consecutive case series. Posterior segment tissues obtained from 37 donors with early and late stages of pseudoexfoliation syndrome without glaucoma, 37 normal age-matched control subjects, 5 eyes with pseudoexfoliation-associated open-angle glaucoma, and 5 eyes with primary open-angle glaucoma (POAG). Protein and mRNA expression of major elastic fiber components (elastin, fibrillin-1, fibulin-4), collagens (types I, III, and IV), and lysyl oxidase crosslinking enzymes (LOX, LOXL1, LOXL2) were assessed in situ by quantitative real-time polymerase chain reaction, (immuno)histochemistry, and light and electron microscopy. Lysyl oxidase-dependent elastin fiber assembly was assessed by primary optic nerve head astrocytes in vitro. Expression levels of elastic proteins, collagens, and lysyl oxidases in the lamina cribrosa. Lysyl oxidase-like 1 proved to be the major lysyl oxidase isoform in the normal lamina cribrosa in association with a complex elastic fiber network. Compared with normal and POAG specimens, lamina cribrosa tissues obtained from early and late stages of pseudoexfoliation syndrome without and with glaucoma consistently revealed a significant coordinated downregulation of LOXL1 and elastic fiber constituents on mRNA and protein level. In contrast, expression levels of collagens and other lysyl oxidase isoforms were not affected. Dysregulated expression of LOXL1 and elastic proteins was associated with pronounced (ultra)structural alterations of the elastic fiber network in the laminar beams of pseudoexfoliation syndrome eyes. Inhibition of LOXL1 interfered with elastic fiber assembly by optic nerve head astrocytes in vitro. The findings provide evidence for a pseudoexfoliation-specific elastinopathy of the lamina cribrosa resulting from a primary disturbance in LOXL1 regulation and elastic fiber homeostasis, possibly rendering pseudoexfoliation syndrome eyes more vulnerable to pressure-induced optic nerve damage and glaucoma development and progression. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. Complications and outcomes of primary phacotrabeculectomy with mitomycin C in a multi-ethnic asian population.

    PubMed

    Chen, David Z; Koh, Victor; Sng, Chelvin; Aquino, Maria C; Chew, Paul

    2015-01-01

    To determine the occurrence of intraoperative and postoperative complications up to three years after primary phacotrabeculectomy with intraoperative use of Mitomycin C (MMC) in primary open angle (POAG) and primary angle closure glaucoma (PACG) patients, and the effect of postoperative complications on surgical outcome. Retrospective review of 160 consecutive patients with POAG (n = 105) and PACG (n = 55), who underwent primary phacotrabeculectomy with MMC at the National University Hospital, Singapore, from January 1, 2008 to December 31, 2010. Data was collected using a standardized form that included patient demographic information, ocular characteristics and postoperative complications, including hypotony (defined as intraocular pressure < 6 mmHg), shallow anterior chamber (AC) and hyphema. The mean age ± standard deviation (SD) of patients was 68.2 ± 8.2 years. No patient lost light perception during duration of follow-up. 77% of the postoperative complications occurred within the first month only. The commonest complications were hypotony (n = 41, 25.6%), hyphema (n = 16, 10.0%) and shallow AC (n = 16, 10.0%). Five patients (3.1%) required reoperation for their complications. Early hypotony (defined as hypotony < 30 days postoperatively) was an independent risk factor for surgical failure (hazard ratio [HR], 5.1; 95% CI, 1.6-16.2; p = 0.01). Hypotony with another complication was also a risk factor for surgical failure (p < 0.02). Hypotony, hyphema and shallow AC were the commonest postoperative complications in POAG and PACG patients after phacotrabeculectomy with MMC. Most complications were transient and self-limiting. Early hypotony within the first month was a significant risk factor for surgical failure.

  1. A Comparison of Open and Endoscopic Repair of Full-Thickness Tears of the Gluteus Medius Tendon at a Minimum of 2 Years Follow-up

    PubMed Central

    Nawabi, Danyal H.; Wentzel, Catherine; Ranawat, Anil S.; Bedi, Asheesh; Kelly, Bryan T.

    2015-01-01

    Objectives: Historically, tears of the gluteus medius tendon were repaired via an open approach yielding excellent outcomes. With the advent of hip arthroscopy, endoscopic techniques have been developed to repair abductor tears which have shown favorable early outcomes. The open technique may still be preferred for large tears with retraction (>4cm), but there is a paucity of data comparing open and endoscopic approaches. The purpose of this study was to compare the outcomes of open and endoscopic repair of full-thickness tears of the gluteus medius tendon. We hypothesized that the outcomes of the two approaches would be similar but that the open technique would have shorter surgical times. Methods: Between March 2010 and June 2012, 1267 patients (1518 hips) undergoing a hip preservation procedure were prospectively entered into a registry. From this cohort, we identified 27 patients (30 hips) that had undergone repair of the gluteus medius tendon with a minimum of 2 years follow-up. Nine patients (9 hips) had an open repair and 18 patients (21 hips) had an endoscopic repair. Patient-reported outcome scores, including the Modified Harris Hip Score (mHHS), the Hip Outcome Score-Activity of Daily Living (HOS-ADL), and the Sport-specific Subscale (HOS-SSS) were obtained preoperatively and at 1, 2, and 3 years postoperatively. Surgery time was obtained using operating room records. The femoral neck shaft angle (FNSA) and lateral center-edge angle (LCEA) were measured on preoperative radiographs. Continuous and categorical variables were compared between endoscopic and open abductor repair patients using independent-samples t-tests and chi-square or Fisher's exact tests (as appropriate), respectively. Given the limited sample size, no adjusted or matched analyses were performed. Results: The mean age (±SD) of the open and endoscopic groups was 62.0 ± 9.9 years and 51.6 ± 13.6 years respectively (p=0.05). There were 6 females (67%) in the open group and 17 females (94%) in the endoscopic group (p=0.09). Seven hips (78%) in the open group had varus necks (FNSA30°) compared to 15 hips (54%) in the endoscopic group (p=0.93). At a mean follow-up of 38.1 months (range, 24-87 months), there were large (> 35 points) and significant improvements (p0.8). One patient (11.1%) in the open group had a poor clinical outcome compared to 2 patients (11.1%) in the endoscopic group that required revision abductor repairs at 5 and 24 months respectively. The mean surgical time was 98.7 ± 21.3 minutes in the open and 122.0 ± 26.8 minutes in the endoscopic group (p=0.003). Conclusion: This study demonstrates that an open gluteus medius tendon repair results in a significant improvement in clinical outcome, that is similar to the scores seen after endoscopic repair. Varus femoral necks and acetabular overcoverage are common features of hips with abductor tears and may be useful diagnostic aids. The surgical time for an open technique is significantly shorter than the endoscopic technique. We recommend an open technique where an intra-articular hip arthroscopy is not required, or in those patients with large and retracted tears.

  2. Comparison of patrons of hotels with early opening and standard hours.

    PubMed

    Smith, D I

    1986-02-01

    A comparison was made of 72 men who were patrons in hotels with 6 A.M. or 7 A.M. opening, with a control group of 87 men interviewed in nearby hotels with 10 A.M. opening. The two groups were very similar on biographical characteristics, yet the men in the early-opening group consumed significantly more alcohol, had more drinking sessions, spent longer in drinking, and had significantly higher SMAST scores. The early opening was apparently facilitating problem drinking.

  3. Diagnostic accuracy of ganglion cell complex substructures in different stages of primary open-angle glaucoma.

    PubMed

    Elbendary, Amal M; Abd El-Latef, Mohamed Hafez; Elsorogy, Hisham I; Enaam, Kamal M

    2017-08-01

    To evaluate diagnostic accuracy of substructure of ganglion cell complex versus peripapillary nerve fiber layer (NFL) thickness using spectral domain optical coherence tomography (SD-OCT) in different stages of glaucoma. Thirty eyes were normal, 120 were glaucomatous. Glaucomatous eyes were classified into: early glaucoma (46), moderate glaucoma (48), and severe glaucoma (26). Perimetry and SD-OCT were done. Peripapillary NFL thickness, ganglion cell layer (GCL), macular NFL thickness, combined GCL and macular ganglion cell complex (GCC), were recorded. Area under receiver operating characteristic curves (AUCs) was used to verify performance of different OCT parameters. Peripapillary NFL, GCL, and GCC thickness values were significantly different in all stages of glaucoma. All comparisons were significantly different; normal versus early, early versus moderate and moderate versus severe. The best parameters that distinguished normal from early stage were: peripapillary NFL (AUC: 0.90), GCC (AUC: 0.75), early from moderate stage were: peripapillary NFL thickness (AUC: 0.85), GCL (0.81),GCC (0.81), moderate from severe stage were: GCC (AUC:0.95), macular NFL (AUC:0.91), GCL (AUC:0.89), and peripapillary NFL (AUC:0.88). Peripapllary NFL and GCC thinning showed paradoxical course. The most diagnosed parameter in early glaucoma was peripapillary NFL and in severe glaucoma was GCC. In severe glaucoma, macular NFL showed higher diagnostic power than GCL and peripapillary NFL. Ganglion cell complex mapping may provide good alternative to optic disc imaging in advanced glaucoma with poor fixation. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  4. Ocular surface disease incidence in patients with open-angle glaucoma.

    PubMed

    Radenković, Marija; Stanković-Babić, Gordana; Jovanović, Predrag; Djordjević-Jocić, Jasmina; Trenkić-Božinović, Marija

    2016-01-01

    Ocular surface disease (OSD) is a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbances, tear film instability with potential damage to the ocular surface, accompanied by increased tear film osmolarity and inflammation of the ocular surface. It is a consequence of disrupted homeostasis of lacrimal functional unit. The main pathogenetic mechanism stems from tear hyperosmolarity and tear film instability. The etiological classification is hyposecretory (Sy-Sjögren and non-Sjögren) and evaporative (extrinsic and intrinsic) form. Delphi panel classification grades disease stages. Antiglaucoma topical therapy causes exacerbation or occurrence of symptoms of dry eye due to main ingredients or preservatives (benzalkonium chloride – BAK), which are dose- and time-dependent. BAK reduces the stability of the lipid layer of tears, the number of goblet cells, induces apoptosis and inflammatory infiltration. The aim of this study was the analysis of the OSD incidence in open-angle glaucoma patients caused by topical medicamentous therapy. Retrospective analysis of examined patients with open-angle glaucoma was used. Increased incidence of moderate and advanced OSD Index degrees in the group of primary open-angle glaucoma (POAG) and pseudoexfoliative glaucoma. According to the Delphi Panel Scale the most common grade is IIb (POAG and pseudoexfoliative glaucoma). Evaporative form of OSD prevailed in all treatment groups. High percentage of dry eye in patients with higher concentrations of preservatives applied was noticed. OSD should be timely diagnosed and treated. Dry eye has an impact on surgical outcome and postoperative visual acuity, and in order to improve patient compliance and quality of life, symptoms of dry eye should be addressed and medications with lower concentrations of preservatives should be applied.

  5. Open wedge high tibial osteotomy using three-dimensional printed models: Experimental analysis using porcine bone.

    PubMed

    Kwun, Jun-Dae; Kim, Hee-June; Park, Jaeyoung; Park, Il-Hyung; Kyung, Hee-Soo

    2017-01-01

    The purpose of this study was to evaluate the usefulness of three-dimensional (3D) printed models for open wedge high tibial osteotomy (HTO) in porcine bone. Computed tomography (CT) images were obtained from 10 porcine knees and 3D imaging was planned using the 3D-Slicer program. The osteotomy line was drawn from the three centimeters below the medial tibial plateau to the proximal end of the fibular head. Then the osteotomy gap was opened until the mechanical axis line was 62.5% from the medial border along the width of the tibial plateau, maintaining the posterior tibial slope angle. The wedge-shaped 3D-printed model was designed with the measured angle and osteotomy section and was produced by the 3D printer. The open wedge HTO surgery was reproduced in porcine bone using the 3D-printed model and the osteotomy site was fixed with a plate. Accuracy of osteotomy and posterior tibial slope was evaluated after the osteotomy. The mean mechanical axis line on the tibial plateau was 61.8±1.5% from the medial tibia. There was no statistically significant difference (P=0.160). The planned and post-osteotomy correction wedge angles were 11.5±3.2° and 11.4±3.3°, and the posterior tibial slope angle was 11.2±2.2° pre-osteotomy and 11.4±2.5° post-osteotomy. There were no significant differences (P=0.854 and P=0.429, respectively). This study showed that good results could be obtained in high tibial osteotomy by using 3D printed models of porcine legs. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Changes in the retrobulbar arterial circulation after decrease of the elevated intraocular pressure in men and women with primary open angle glaucoma.

    PubMed

    Marjanović, Ivan; Martinez, Antonio; Marjanović, Marija; Kontić, Djordje; Hentova-Senćanić, Paraskeva; Marković, Vujica; Bozić, Marija

    2013-01-01

    An altered perfusion of the optic nerve head has been proposed as a pathogenic factor of glaucoma. The aim of this study was to evaluate the changes of the hemodynamic parameters in the retrobulbar arterial circulation after decrease of the elevated intraocular pressure (IOP) in women and men with primary open angle glaucoma. The study included 60 patients (33 males and 27 females) older than 50 years, with diagnosed and treated primary open angle glaucoma (77 eyes of 39 patients had increased IOP, > 25 mm Hg).They were examined at the Clinic of Eye Diseases (complete ophthalmologic exam) and Clinic of Neurology, Clinical Center of Serbia, Belgrade, from December 2009 to December 2010. Imaging of hemodynamic parameters of three retrobulbar arterial vessels: ophthalmic, central retinal and posterior ciliary arteries with color Doppler was performed. Among women, hemodynamic arterial parameter of the peak-systolic velocity was increased in the central retinal artery and decreased in the ophthalmic artery and posterior ciliary arteries; end-diastolic velocity was increased in all three retrobulbar vascular levels; Pourcelot resistivity index was increased, but pulsatility index was decreased in all three vessels. Among men, peak-systolic velocity, end-diastolic velocity and pulsatility index were decreased in all three vessels; resistivity index was increased in the ophthalmic artery, but decreased in the central retinal artery and posterior ciliary arteries. There was a significant change of the ophthalmic artery pulsatility index in women, and the end-diastolic velocity of the ophthalmic artery in men. There was a difference of the retrobulbar arterial circulation between women and men with primary open angle glaucoma after decrease of the elevated intraocular pressure.The role of vascular factors in the supply of the optic disc neuroretinal rim is important.

  7. Lateral displacement, sulcus angle and trochlear angle are associated with early patellofemoral osteoarthritis following anterior cruciate ligament reconstruction.

    PubMed

    Macri, Erin M; Culvenor, Adam G; Morris, Hayden G; Whitehead, Timothy S; Russell, Trevor G; Khan, Karim M; Crossley, Kay M

    2017-05-09

    Patellofemoral osteoarthritis (PFOA) occurs in approximately half of anterior cruciate ligament (ACL)-injured knees within 10-15 years of trauma. Risk factors for post-traumatic PFOA are poorly understood. Patellofemoral alignment and trochlear morphology may be associated with PFOA following ACL reconstruction (ACLR), and understanding these relationships, particularly early in the post-surgical time period, may guide effective early intervention strategies. In this study, patellofemoral alignment and trochlear morphology were investigated in relation to radiographic features of early PFOA 1-year post-ACLR. Participants (aged 18-50 years) had undergone ACLR approximately 1 year prior to being assessed. Early PFOA was defined as presence of a definite patellofemoral osteophyte on lateral or skyline radiograph. Sagittal and axial plane alignment and trochlear morphology were estimated using MRI. Using logistic regression, the relationship between alignment or morphology and presence of osteophytes was evaluated. Of 111 participants [age 30 ± 8.5; 41 (37%) women], 19 (17%) had definite osteophytes, only two of whom had had patellofemoral chondral lesions noted intra-operatively. One measure of patellar alignment (bisect offset OR 1.1 [95% confidence interval 1.0, 1.2]) and two measures of trochlear morphology (sulcus angle OR 1.1 [1.0, 1.2], trochlear angle OR 1.2 [1.0, 1.5]) were associated with patellofemoral osteophytes. Patellofemoral malalignment and/or altered trochlear morphology were associated with PFOA 1 year following ACLR compared to individuals post-ACLR without these features. Clarifying the role of alignment and morphology in post-traumatic PFOA may contribute to improving early intervention strategies aimed at secondary prevention. IV.

  8. Hip arthroscopy versus open surgical dislocation for femoroacetabular impingement

    PubMed Central

    Zhang, Dagang; Chen, Long; Wang, Guanglin

    2016-01-01

    Abstract Background: This meta-analysis aims to evaluate the efficacy and safety of hip arthroscopy versus open surgical dislocation for treating femoroacetabular impingement (FAI) through published clinical trials. Methods: We conducted a comprehensive literature search using PUBMED, EMBASE, and the Cochrane Central Register of Controlled Trials databases for relevant studies on hip arthroscopy and open surgical dislocation as treatment options for FAI. Results: Compared with open surgical dislocation, hip arthroscopy resulted in significantly higher Nonarthritic Hip Scores (NAHS) at 3- and 12-month follow-ups, a significant improvement in NAHS from preoperation to 3 months postoperation, and a significantly lower reoperation rate. Open surgical dislocation resulted in a significantly improved alpha angle by the Dunn view in patients with cam osteoplasty from preoperation to postoperation, compared with hip arthroscopy. This meta-analysis demonstrated no significant differences in the modified Harris Hip Score, Hip Outcome Score-Activities of Daily Living, or Hip Outcome Score-Sport Specific Subscale at 12 months of follow-up, or in complications (including nerve damage, wound infection, and wound dehiscence). Conclusion: Hip arthroscopy resulted in higher NAHS and lower reoperation rates, but had less improvement in alpha angle in patients with cam osteoplasty, than open surgical dislocation. PMID:27741133

  9. The Opening of the Arctic: Establishing a New Security Perimeter for the United States

    DTIC Science & Technology

    2013-02-14

    Eastern oil is projected to come to an end by 2032. British Petroleum, in its annual energy outlook, predicts growth in biofuel supplies and...Inclination angles for GPS and Galileo satellites are 55 and 56 degrees respectively while GLONASS inclination angles are marginally better at 65

  10. Miniaturized haploscope for testing binocular vision

    NASA Technical Reports Server (NTRS)

    Decker, T. A.

    1973-01-01

    Device can reproduce virtually all binocular stimulus conditions (target configuration, vergence angle, and accommodative distance) used to test binocular performance. All subsystems of electronic controls are open-loop and solid-state-controlled and, with the exception of vergence angle drive, utilize dc stepping motors as prime movers. Arrangement is also made for readouts of each variable.

  11. Fixed combination of bimatoprost and timolol in patients with primary open-angle glaucoma or ocular hypertension with inadequate IOP adjustment

    PubMed Central

    Brief, Gerrett; Lammich, Tobias; Nagel, Edgar; Pfennigsdorf, Sabine; Spraul, Christoph W; Ho, Selwyn

    2010-01-01

    Objective To assess the efficacy and tolerability of a fixed combination of bimatoprost and timolol (BTFC) in a large patient sample in a clinical setting. Methods In this multicenter, observational, noncontrolled, open-label study, patients (n = 1862) with primary open-angle glaucoma or ocular hypertension were treated with BTFC. Assessments were made at baseline, six weeks, and three months. Results Prior to starting BTFC, 92.3% of patients were taking other ocular hypotensive medications. In the overall group at three months, mean intraocular pressure was reduced from baseline (21.7 ± 4.5 mmHg and 21.8 ± 4.9 mmHg for the right and left eye, respectively) to 16.1 ± 3.0 mmHg for each eye (P < 0.0001). The majority of patients (92%) reported no adverse events. The most commonly reported adverse events (in >1% of patients) were eye irritation, and ocular and conjunctival hyperemia. Adherence to treatment was generally better than (35.4%) or the same as (57.5%) with prior therapy. BTFC tolerability was rated as excellent or good by 92.3% of physicians and 85.8% of patients. Conclusions In a large group of patients with primary open-angle glaucoma or ocular hypertension, treatment with BTFC was associated with consistent reductions in IOP, improved adherence to treatment, and good tolerability. PMID:20957059

  12. Leaf movement in Calathea lutea (Marantaceae).

    PubMed

    Herbert, Thomas J; Larsen, Parry B

    1985-09-01

    Calathea lutea is a broad-leaved, secondary successional plant which shows complex leaf movements involving both elevation and folding of the leaf surface about the pulvinus. In the plants studied, mean leaf elevation increased from approximately 34 degrees in the early morning to 70 degrees at noon while the angle of leaf folding increased from 13 degrees to 50 degrees over the same time period. During the period from early morning to noon, these movements resulted in a significant decrease in the cosine of the angle of incidence, a measure of the direct solar radiation intercepted. The observed changes in elevational angle significantly reduce the cosine of angle of incidence while folding does not significantly reduce the fraction of direct solar radiation intercepted during the period of direct exposure of the leaf surface to the solar beam. Since elevational changes seem to account for the reduction in exposure to direct solar radiation, the role of folding remains unclear.

  13. Anterior chamber angle assessment using gonioscopy and ultrasound biomicroscopy.

    PubMed

    Narayanaswamy, Arun; Vijaya, Lingam; Shantha, B; Baskaran, Mani; Sathidevi, A V; Baluswamy, Sukumar

    2004-01-01

    Comparison of anterior chamber angle measurements using ultrasound biomicroscopy (UBM) and gonioscopy. Five hundred subjects were evaluated for grading of angle width by the Shaffer method. UBM was done in the same group to document angle width, angle opening distance (AOD 500), and anterior chamber depth. Biometric parameters were documented in all subjects. UBM and gonioscopic findings were compared. A study was conducted in 282 men and 218 women with a mean age of 57.32 +/- 12.48 years. Gonioscopic grading was used to segregate occludable (slit-like, grades 1 and 2) from nonoccludable (grades 3 and 4) angles. Subjective assessment by gonioscopy resulted in an overestimation of angle width within the occludable group when compared with values obtained by UBM. This did not affect the segregation of occludable versus nonoccludable angles by gonioscopy. Biometric parameters in eyes with occludable angles were significantly lower in comparison with eyes with nonoccludable angles, except for lens thickness. AOD 500 correlated well with angle width. We concluded that clinical segregation into occludable and nonoccludable angles by an experienced observer using gonioscopy is fairly accurate. However, UBM is required for objective quantification of angles, and AOD 500 can be a reliable and standard parameter to grade angle width.

  14. The Impact of Open Licensing on the Early Reader Ecosystem

    ERIC Educational Resources Information Center

    Butcher, Neil; Hoosen, Sarah; Levey, Lisbeth; Moore, Derek

    2016-01-01

    The Impact of Open Licensing on the Early Reader Ecosystem examines how to use open licensing to promote quality learning resources for young children that are relevant and interesting. Research in early reading tends to focus on traditional publishing value and supply chains, without taking much consideration of new approaches and solutions…

  15. Camouflage of a high-angle skeletal Class II open-bite malocclusion in an adult after mini-implant failure during treatment.

    PubMed

    Franzotti Sant'Anna, Eduardo; Carneiro da Cunha, Amanda; Paludo Brunetto, Daniel; Franzotti Sant'Anna, Claudia

    2017-03-01

    The treatment of skeletal anterior open-bite malocclusion requires complex orthodontic planning that considers its multifactorial etiology, treatment limitations, and high relapse rates. This case report illustrates a successful treatment approach for a skeletal high-angle Class II malocclusion in an adult with a severe open bite. The treatment consisted of a high-pull headgear therapy after mini-implants failure during fixed orthodontic therapy. Adequate esthetics and function were achieved. Despite its low probability, the unexpected event of mini-implant loosening during complex treatments should be considered. Therefore, classic orthodontic mechanics should be established, especially when treating patients for whom invasive procedures such as miniplates or orthognathic surgery are not available options. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  16. Effect and safety of early weight-bearing on the outcome after open-wedge high tibial osteotomy: a systematic review and meta-analysis.

    PubMed

    Lee, O-Sung; Ahn, Soyeon; Lee, Yong Seuk

    2017-07-01

    The purpose of this systematic review and meta-analysis was to evaluate the effectiveness and safety of early weight-bearing by comparing clinical and radiological outcomes between early and traditional delayed weight-bearing after OWHTO. A rigorous and systematic approach was used. The methodological quality was also assessed. Results that are possible to be compared in two or more than two articles were presented as forest plots. A 95% confidence interval was calculated for each effect size, and we calculated the I 2 statistic, which presents the percentage of total variation attributable to the heterogeneity among studies. The random-effects model was used to calculate the effect size. Six articles were included in the final analysis. All case groups were composed of early full weight-bearing within 2 weeks. All control groups were composed of late full weight-bearing between 6 weeks and 2 months. Pooled analysis was possible for the improvement in Lysholm score, but there was no statistically significant difference shown between groups. Other clinical results were also similar between groups. Four studies reported mechanical femorotibial angle (mFTA) and this result showed no statistically significant difference between groups in the pooled analysis. Furthermore, early weight-bearing showed more favorable results in some radiologic results (osseointegration and patellar height) and complications (thrombophlebitis and recurrence). Our analysis supports that early full weight-bearing after OWHTO using a locking plate leads to improvement in outcomes and was comparable to the delayed weight-bearing in terms of clinical and radiological outcomes. On the contrary, early weight-bearing was more favorable with respect to some radiologic parameters and complications compared with delayed weight-bearing.

  17. Entry, Descent, and Landing Guidance and Control Approaches to Satisfy Mars Human Mission Landing Criteria

    NASA Technical Reports Server (NTRS)

    Dwyer Cianciolo, Alicia; Powell, Richard W.

    2017-01-01

    Precision landing on Mars is a challenge. All Mars lander missions prior to the 2012 Mars Science Laboratory (MSL) had landing location uncertainty ellipses on the order of hundreds of kilometers. Sending humans to the surface of Mars will likely require multiple landers delivered in close proximity, which will in turn require orders of magnitude improvement in landing accuracy. MSL was the first Mars mission to use an Apollo-derived bank angle guidance to reduce the size of the landing ellipse. It utilized commanded bank angle magnitude to control total range and bank angle reversals to control cross range. A shortcoming of this bank angle guidance is that the open loop phase of flight created by use of bank reversals increases targeting errors. This paper presents a comparison of entry, descent and landing performance for a vehicle with a low lift-to-drag ratio using both bank angle control and an alternative guidance called Direct Force Control (DFC). DFC eliminates the open loop flight errors by directly controlling two forces independently, lift and side force. This permits independent control of down range and cross range. Performance results, evaluated using the Program to Optimize Simulated Trajectories (POST2), including propellant use and landing accuracy, are presented.

  18. Reflectance Spectra of Peacock Feathers and the Turning Angles of Melanin Rods in Barbules.

    PubMed

    Okazaki, Toshio

    2018-02-01

    I analyzed the association between the reflectance spectra and melanin rod arrangement in barbules of the eyespot of peacock feathers. The reflectance spectra from the yellow-green feather of the eyespot indicated double peaks of 430 and 540 nm. The maximum reflectance spectrum of the blue feather was 480 nm, and that of the dark blue feather was 420 nm. The reflectance spectra from brown feathers indicated double peaks of 490 and 610 nm. Transmission electron microscopic analysis confirmed that melanin rods were arranged fanwise in the outer layer toward the barbule tips. In addition, using polarized light microscope, I attempted to determine whether the turning angles of melanin rods in the barbules reflected different colors. The turning angle of the polarizing axis of the barbules was supported by that of the melanin rods, observed using transmission electron microscopic images. To compare the turning angle of melanin rods in the respective barbules, I calculated the opening width of the fanwise melanin rods by dividing the width of the barbules by the turning angle of the polarizing axis of barbules and obtained a positive correlation between the reflectance spectra and opening width of the fanwise melanin rods. Moreover, the widely spreading reflection from the barbules may occur because of the fanwise melanin rod arrangement.

  19. Agreement between gonioscopy and ultrasound biomicroscopy in detecting iridotrabecular apposition.

    PubMed

    Barkana, Yaniv; Dorairaj, Syril K; Gerber, Yariv; Liebmann, Jeffrey M; Ritch, Robert

    2007-10-01

    To assess the agreement between findings obtained at dark-room gonioscopy and ultrasound biomicroscopy (UBM) in the diagnosis of iridotrabecular apposition in light and dark conditions. We enrolled patients with appositional angle closure at dark-room gonioscopy performed using a 1-mm slitlamp beam that did not cross the pupil. Ultrasound biomicroscopic images were acquired in normal room light and subsequently with all room lights off. Images were evaluated for the presence or absence of iris-cornea contact. The angle opening distance at 500 microm was calculated. Iridotrabecular apposition in at least 1 angle quadrant was demonstrated in all 18 eyes at dark-room gonioscopy, 17 eyes (94%) at dark-room UBM, and only 10 eyes (56%) at UBM in room light. Of 18 superior angles that were appositionally closed at dark-room gonioscopy, apposition was demonstrated on UBM images in 16 (89%) in a dark room but only 6 (33%) in room light. Angle opening distance was less during dark-room gonioscopy in all but the nasal quadrant. We found high agreement between gonioscopy and UBM when both are performed in a completely dark room. Our findings support the recommendation that, in routine clinical practice, gonioscopy be performed in a dark room to avoid misdiagnosis of treatable iridotrabecular apposition.

  20. A mathematical method for precisely calculating the radiographic angles of the cup after total hip arthroplasty.

    PubMed

    Zhao, Jing-Xin; Su, Xiu-Yun; Xiao, Ruo-Xiu; Zhao, Zhe; Zhang, Li-Hai; Zhang, Li-Cheng; Tang, Pei-Fu

    2016-11-01

    We established a mathematical method to precisely calculate the radiographic anteversion (RA) and radiographic inclination (RI) angles of the acetabular cup based on anterior-posterior (AP) pelvic radiographs after total hip arthroplasty. Using Mathematica software, a mathematical model for an oblique cone was established to simulate how AP pelvic radiographs are obtained and to address the relationship between the two-dimensional and three-dimensional geometry of the opening circle of the cup. In this model, the vertex was the X-ray beam source, and the generatrix was the ellipse in radiographs projected from the opening circle of the acetabular cup. Using this model, we established a series of mathematical formulas to reveal the differences between the true RA and RI cup angles and the measurements results achieved using traditional methods and AP pelvic radiographs and to precisely calculate the RA and RI cup angles based on post-operative AP pelvic radiographs. Statistical analysis indicated that traditional methods should be used with caution if traditional measurements methods are used to calculate the RA and RI cup angles with AP pelvic radiograph. The entire calculation process could be performed by an orthopedic surgeon with mathematical knowledge of basic matrix and vector equations. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  1. Handling Qualities of a Capsule Spacecraft During Atmospheric Entry

    NASA Technical Reports Server (NTRS)

    Bilimoria, Karl D.; Mueller, Eric R.

    2010-01-01

    A piloted simulation was conducted to study handling qualities for capsule spacecraft entering the Earth s atmosphere. Eight evaluation pilots, including six pilot astronauts, provided Cooper-Harper ratings, workload ratings, and qualitative comments. The simulation began after descending through the atmospheric entry interface point and continued until the drogue parachutes deployed. There were two categories of piloting tasks, both of which required bank angle control. In one task category, the pilot followed a closed-loop bank angle command computed by the backup guidance system to manage g-loads during entry. In the other task category, the pilot used intuitive rules to determine the desired bank angle independently, based on an open-loop schedule of vertical speed, Mach, and total energy specified at several range-to-target gates along the entry trajectory. Pilots were able to accurately track the bank angle guidance commands and steered the capsule toward the recovery site with essentially the same range error as the benchmark autopilot trajectory albeit with substantially higher propellant usage, and the handling qualities for this task were satisfactory. Another key result was that the complex piloting task of atmospheric entry could be performed satisfactorily, even in the presence of large dispersions, by controlling bank angle to follow a simple open-loop schedule.

  2. HST Multicolor (255-1042 nm) Photometry of Saturn's Main Rings. 1; Radial Profiles, Phase and Opening Angle Variations, and Regional Spectra

    NASA Technical Reports Server (NTRS)

    Cuzzi, Jeffrey N.; French, Richard G.; Dones, Luke; DeVincenzi, Donald (Technical Monitor)

    2001-01-01

    The main rings of Saturn were observed with the Planetary Camera of the WFPC2 instrument on the Hubble Space Telescope (HST) from September 1996 to August 2000 as the'ring opening angle to Earth and Sun increased from 4 deg to 24 deg, with a spread of phase angles between 0.3 deg and 6 deg at each opening angle. The rings were routinely observed in the five HST wideband UBVRI filters (F336W, F439W, F555W, F675W, and F814W) and occasionally in the F255W, F785LP, and F1042M filters. The emphasis in this series of papers will be on radial color (implying compositional) variations. In this first paper we describe the analysis technique and calibration procedure, note revisions in a previously published Voyager ring color data analysis, and present new results based on over 100 HST images. In the 300-600 nm spectral range where the rings are red, the 555nm/336nm ratio increases by about 14% as the phase angle increases from 0.3 deg to 6 deg. This effect, never reported previously for the rings, is significantly larger than the phase reddening which characterizes other icy objects, primarily because of the redness of the rings. However, there is no discernible tendency for color to vary with ring opening angle at a given phase angle, and there is no phase variation of color where the spectrum is flat. We infer from this combination of facts that multiple intraparticle scattering, either in a regolith or between facets of an unusually rough surface, is important in these geometries, but that multiple interparticle scattering in a vertically extended layer is not. Voyager color ratios at a phase angle of 14 deg are compatible with this trend, but calibration uncertainties prevent their use in quantitative modeling. Overall ring-average spectra are compatible with those of earlier work within calibration uncertainties, but ring spectra vary noticeably with region. We refine and subdivide the regions previously defined by others. The variation seen between radial profiles of ratios between different wavelength suggests the presence of multiple compositional components with different radial distributions. We present new radial profiles of far UV color ratio (F336W/F255W) showing, substantial global variations having a different radial structure than seen between 555 and 336nm. We also find evidence for absorption in the 850nm spectral range (a feature previously only weakly indicated in ring-averaged spectra) primarily through its radial variation; it is located primarily in the C ring, where the particles are known to have lower albedo, and is consistent with "interplanetary pollution" of the rings.

  3. The ISW effect and the lack of large-angle CMB temperature correlations

    NASA Astrophysics Data System (ADS)

    Copi, Craig J.; O'Dwyer, Márcio; Starkman, Glenn D.

    2016-12-01

    It is by now well established that the magnitude of the two-point angular-correlation function of the cosmic microwave background temperature anisotropies is anomalously low for angular separations greater than about 60°. Physics explanations of this anomaly typically focus on the properties of the Universe at the surface of last scattering, relying on the fact that large-angle temperature fluctuations are dominated by the Sachs-Wolfe effect (SW). However, these fluctuations also receive important contributions from the integrated Sachs-Wolfe effect (ISW) at both early (eISW) and late (ℓISW) times. Here, we study the correlations in those large-angle temperature fluctuations and their relative contributions to S1/2- the standard measure of the correlations on large angular scales. We find that in the best-fitting lambda cold dark matter (ΛCDM) cosmology, while the autocorrelation of the early contributions (SW plus eISW) dominates S1/2, there are also significant contributions originating from cross-terms between the early and late contributions. In particular, realizations of ΛCDM with low S1/2 are typically produced from a combination of somewhat low pure-early correlations and accidental cancellations among early-late correlations. We also find that if the pure ℓISW autocorrelations were the only contribution to S1/2 in ΛCDM, then the p-value of the observed cut-sky S1/2 would be unremarkable. This suggests that the physical mechanisms operating only at or near the last scattering surface could explain the observed lack of large-angle correlations, though this is not the typical resolution within ΛCDM.

  4. Brightness discrimination test is not useful in screening for open angle glaucoma.

    PubMed

    Peter, E; Thomas, R; Muliyil, J

    1996-06-01

    Brightness discrimination test (BDT) is routinely employed to assess asymmetrical optic nerve dysfunction and has been suggested as a screening test for primary open angle glaucoma (POAG). We tested the reliability and validity of BDT in the diagnosis of POAG. The study groups included 34 patients with established primary open angle glaucoma, 20 glaucoma suspects, and 33 age-sex matched controls. Cataract was not an exclusion criterion in these groups. The normal brightness score was determined to be 88% (mean score, 94%-2 SD) in a pilot study. Brightness discrimination test was performed in all subjects by two observers independently. BDT showed an excellent interobserver agreement (weighted Kappa 0.84). The presence of a cataract alone increased the risk of brightness impairment twofold, glaucoma alone increased the risk eightfold, and the presence of both conditions by 17 times compared to those with neither condition. BDT was not a useful test in the diagnosis of POAG (sensitivity 67% and specificity 93%); the ability to detect a significant field defect was also poor (sensitivity 53% and specificity 76%). There was poor association between decreased brightness scores and asymmetrical field defects as determined by the Humphrey's field analyzer (HFA).

  5. Characterizing the “POAGome”: A bioinformatics-driven approach to primary open-angle glaucoma

    PubMed Central

    Danford, Ian D.; Verkuil, Lana D.; Choi, Daniel J.; Collins, David W.; Gudiseva, Harini V.; Uyhazi, Katherine E.; Lau, Marisa K.; Kanu, Levi N.; Grant, Gregory R.; Chavali, Venkata R.M.; O’Brien, Joan M.

    2017-01-01

    Primary open-angle glaucoma (POAG) is a genetically, physiologically, and phenotypically complex neurodegenerative disorder. This study addressed the expanding collection of genes associated with POAG, referred to as the “POAGome.” We used bioinformatics tools to perform an extensive, systematic literature search and compiled 542 genes with confirmed associations with POAG and its related phenotypes (normal tension glaucoma, ocular hypertension, juvenile open-angle glaucoma, and primary congenital glaucoma). The genes were classified according to their associated ocular tissues and phenotypes, and functional annotation and pathway analyses were subsequently performed. Our study reveals that no single molecular pathway can encompass the pathophysiology of POAG. The analyses suggested that inflammation and senescence may play pivotal roles in both the development and perpetuation of the retinal ganglion cell degeneration seen in POAG. The TGF-β signaling pathway was repeatedly implicated in our analyses, suggesting that it may be an important contributor to the manifestation of POAG in the anterior and posterior segments of the globe. We propose a molecular model of POAG revolving around TGF-β signaling, which incorporates the roles of inflammation and senescence in this disease. Finally, we highlight emerging molecular therapies that show promise for treating POAG. PMID:28223208

  6. Oxidative stress markers in patients with primary open-angle glaucoma.

    PubMed

    Ghanem, Asaad A; Arafa, Lamiaa F; El-Baz, Ayman

    2010-04-01

    To investigate the levels of antioxidant enzymes catalase (CAT), glutathione peroxidase (GPO), superoxide dismutase (SOD), and malondialdehyde (MDA) in human eyes with primary open-angle glaucoma (POAG) and to correlate their concentrations with severity of glaucoma. A prospective cases control study. Thirty patients with primary open-angle glaucoma and twenty-five patients with senile cataracts of matched age and gender were included in the study prospectively. Aqueous humor samples were obtained by paracentesis at the time of elective surgery for glaucomatous and cataractous patients. Aqueous humor were analyzed for CAT, GPO, SOD, and MDA status. GPO, SOD, and MDA enzyme levels revealed a high significant increase in aqueous humor of POAG patients with respect to the comparative group of cataract patients (P < 0.001). No significant difference in the activity of CAT enzyme in aqueous humor of POAG and cataract patient (P = 0.201). Significant correlation was found between the MDA enzyme level and severe visual field loss (P < 0.001) in POAG patients. Increased levels of aqueous humor GPO, SOD, and MDA may be associated with POAG. In addition, they may be useful antioxidant enzyme levels in aqueous humor of POAG patients as a result of glaucoma disease and not a cause.

  7. Prospective, non-interventional, multicenter study of the intraocular pressure-lowering effects of prostaglandin analog/prostamide-containing therapies in previously treated patients with open-angle glaucoma or ocular hypertension

    PubMed Central

    Tamçelik, Nevbahar; Izgi, Belgin; Temel, Ahmet; Yildirim, Nilgun; Okka, Mehmet; Özcan, Altan; Yüksel, Nurşen; Elgin, Ufuk; Altan, Çiğdem; Ozer, Baris

    2017-01-01

    Objective The objective of this study was to assess the intraocular pressure (IOP)-lowering efficacy, tolerability, safety, and usage patterns of prostaglandin analog/prostamide (PGA/P)-containing topical ocular hypotensives in ocular hypertension (OHT) and primary open-angle glaucoma in the Turkish clinical setting. Methods This non-interventional, multicenter study enrolled previously treated patients who failed to achieve target IOP (or experienced unacceptable adverse events [AEs]) and were prescribed a PGA/P-containing IOP-lowering agent. Treatment was initiated at baseline (V1), and patients returned at weeks 4–6 (V2) and 8–12 (V3). The primary efficacy measure was the change in IOP from baseline at V3 in each eye. The secondary measures were physician’s assessment of IOP-lowering efficacy, patients (%) reaching target IOP determined at V1, hyperemia score, physician and patient assessment of study treatment tolerability at V3, and AE frequency/severity. A subgroup analysis of patients receiving the most common study treatment was conducted. All analyses were performed using the safety population (patients who received one or more doses and had any data available). Results Of 358 enrolled patients, 60.6% had primary open-angle glaucoma, 29.9% had secondary open-angle glaucoma (protocol amendment), and 13.1% had OHT; 13 patients had multiple diagnoses. At V3, the mean IOP change from baseline was ≥−4.2 mmHg (≥21.1%). IOP met or was lower than the target in 81.7% of patients, 95% exhibited none to mild conjunctival hyperemia (most common AE), and tolerability was rated good/very good by >91.1% of patients and physicians. The results were similar in patients who received the most common study treatment, bimatoprost 0.03%/timolol 0.5% (bim/tim; n=310). Conclusion PGA/P-containing medications, including bim/tim, significantly reduced IOP in previously treated patients with open-angle glaucoma or OHT; most reached their target IOP or an IOP even lower than their target and reported good/very good tolerability. PGA/P-containing medications such as bim/tim should be considered as a safe, effective therapeutic option for Turkish patients who exhibit poor response, tolerance, or adherence to their previous therapy. PMID:28458511

  8. Anterior capsule relaxing incisions with neodymium:YAG laser for patients at high-risk for anterior capsule contraction.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Hirata, Akira; Hayashi, Hideyuki

    2011-01-01

    To examine the effect of anterior capsule relaxing incisions created with a neodymium:YAG (Nd:YAG) laser on prevention of anterior capsule contraction after cataract surgery in high-risk patients. Hayashi Eye Hospital, Fukuoka, Japan. Randomized masked clinical trials. Patients at high risk for anterior capsule contraction had anterior capsule relaxing incisions in either eye 3 days postoperatively. The anterior capsule opening was measured using a Scheimpflug videophotography system (EAS-1000) immediately and 1, 3, and 6 months after capsulotomy, and the percentage reduction in area was calculated. The degree of intraocular lens (IOL) decentration and tilt, posterior capsule opacification (PCO), and other complications were also assessed. Of the 84 patients included, 30 had primary angle closure, 28 had pseudoexfoliation, and 26 had diabetic retinopathy. There was no significant difference in the mean opening area between fellow eyes at baseline. In patients with primary angle closure, the area was significantly greater and the percentage reduction in area was significantly less in the capsulotomy group than in the no-capsulotomy group (P≤.0428). In patients with pseudoexfoliation or diabetic retinopathy, the percentage reduction was significantly less in the capsulotomy group than in the no-capsulotomy group (P≤.0493), although there was no significant difference in area. No significant difference was found in IOL decentration or tilt, PCO, or incidence of other complications. Neodymium:YAG laser anterior capsule relaxing incisions in the early period after cataract surgery were effective in preventing anterior capsule contraction in high-risk patients and had no adverse effects. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Astrophysically relevant radiatively cooled hypersonic bow shocks in nested wire arrays

    NASA Astrophysics Data System (ADS)

    Ampleford, David

    2009-11-01

    We have performed laboratory experiments which introduce obstructions into hypersonic plasma flows to study the formation of shocks. Astrophysical observations have demonstrated many examples of equivalent radiatively cooled bow shocks, for example the head of protostellar jets or supernova remnants passing through the interstellar medium or between discrete clumps in jets. Wire array z-pinches allow us to study quasi-planar radiatively cooled flows in the laboratory. The early stage of a wire array z-pinch implosion consists of a steady flow of the wire material towards the axis. Given a high rate of radiative cooling, these flows reach high sonic- Mach numbers, typically up to 5. The 2D nature of this configuration allows the insertion of obstacles into the flow, such as a concentric ``inner'' wire array, as has previously been studied for ICF research. Here we study the application of such a nested array to laboratory astrophysics where the inner wires act as obstructions perpendicular to the flow, and induce bow shocks. By varying the wire array material (W/Al), the significance of radiative cooling on these shocks can be controlled, and is shown to change the shock opening angle. As multiple obstructions are present, the experiments show the interaction of multiple bow shocks. It is also possible to introduce a magnetic field around the static object, increasing the opening angle of the shocks. Further experiments can be designed to control the flow density, magnetic field structure and obstruction locations. In collaboration with: S.V. Lebedev, M.E. Cuneo, C.A. Jennings, S.N. Bland, J.P. Chittenden, A. Ciardi, G.N. Hall, S.C. Bott, M. Sherlock, A. Frank, E. Blackman

  10. Costs and utilization of end-stage glaucoma patients receiving visual rehabilitation care: a US multisite retrospective study.

    PubMed

    Gieser, David K; Tracy Williams, R; O'Connell, William; Pasquale, Louis R; Rosenthal, Bruce P; Walt, John G; Katz, Laura M; Siegartel, Lisa R; Wang, Lujing; Rosenblatt, Lisa C; Stern, Lee S; Doyle, John J

    2006-10-01

    Glaucoma is a prevalent ophthalmologic disease and leading cause of blindness. A retrospective analysis was conducted to evaluate resources and costs for end-stage glaucoma patients receiving visual rehabilitation care (VRC). A chart review was conducted in 3 United States VRC centers. Charts of patients with primary open-angle glaucoma as the primary cause of vision loss (1998 to 2003) were selected, yielding 81 records. Data were collected from patient-level billing and reimbursement records (ophthalmologist/optometrist visits, glaucoma medications, procedures, and specialized low-vision and glaucoma-related services). Visual rehabilitation services included utilization of low-vision devices, assessment of daily functioning, orientation and mobility training, and patient counseling. Mean age at baseline was 72.7 years [standard deviation (SD)=17.2, range: 29 to 95]. Of those with known sex (n=77), 55.8% were women. Medicare was the payer type for most patients (59.3%), whereas 20% had Medicaid. Mean number of visits was 7.1 (SD=6.1) in year 1 and 3.7 (SD=4.2) in year 2, for an annual mean of 5.4 (SD=5.0) visits overall. Total mean cost per patient in year 1 was greater than year 2 [$2170 (SD=$2252) vs. $1202 (SD=$1080), respectively]; of the total 2-year costs, 15% were VRC, 37% ophthalmology care, and 48% pharmacy. Analysis of nonpharmacy costs revealed that VRC accounted for 28% and ophthalmology for 72%. End-stage glaucoma is associated with appreciable resource utilization and costs, because of both vision rehabilitation and ophthalmology care. Advanced primary open-angle glaucoma has a substantial cost-of-illness, warranting improved management in early stages of disease.

  11. Differential protein expression in tears of patients with primary open angle and pseudoexfoliative glaucoma.

    PubMed

    Pieragostino, Damiana; Bucci, Sonia; Agnifili, Luca; Fasanella, Vincenzo; D'Aguanno, Simona; Mastropasqua, Alessandra; Ciancaglini, Marco; Mastropasqua, Leonardo; Di Ilio, Carmine; Sacchetta, Paolo; Urbani, Andrea; Del Boccio, Piero

    2012-04-01

    Primary open angle (POAG) and pseudoexfoliative glaucoma (PXG) are the most common primary and secondary forms of glaucoma, respectively. Even though the patho-physiology, aqueous humor composition, risk factors, clinical features, therapy and drug induced ocular surface changes in POAG and PXG have been widely studied, to date information concerning tear protein characterization is lacking. Tears are a source of nourishment for ocular surface tissues and a vehicle to remove local waste products, metabolized drugs and inflammatory mediators produced in several ophthalmic diseases. In glaucoma, the proteomic definition of tears may provide insights concerning patho-physiology of the disease and ocular surface modifications induced by topical therapy. Our study aimed at characterizing protein patterns in tears of patients with medically controlled POAG and PXG. A comparative tears proteomic analysis by label-free LC-MS(E) highlighted differences in the expression of several proteins in the two glaucoma sub-types and control subjects, highlighting inflammation pathways expressed in both diseases. Results were independently reconfirmed by SDS-PAGE and linear MALDI-TOF MS, validating altered levels of Lysozyme C, Lipocalin-1, Protein S100, Immunoglobulins and Prolactin Inducible Protein. Moreover, we found a differential pattern of phosphorylated Cystatin-S that distinguishes the two pathologies. The most relevant results suggest that in both pathologies there may be active inflammation pathways related to the disease and/or induced by therapy. We show, for the first time, tear protein patterns expressed under controlled intraocular pressure conditions in POAG and PXG subjects. These findings could help in the understanding of molecular machinery underlying these ophthalmologic diseases, resulting in early diagnosis and more specific therapy.

  12. Unit Advancement Flap for Lower Lip Reconstruction.

    PubMed

    Ogino, Akihiro; Onishi, Kiyoshi; Okada, Emi; Nakamichi, Miho

    2018-05-01

    Lower lip reconstruction requires consideration of esthetic and functional outcome in selecting a surgical procedure, and reconstruction with local tissue is useful. The authors reconstructed full-thickness defects with a unit advancement flap. Reconstruction was performed using this method in 4 patients with lower lip squamous cell carcinoma in whom tumor resection with preservation of the mouth angle was possible. The lower lip resection width was 30 to 45 mm, accounting for 50% to 68% of the entire width of the lower lip. The flap was prepared by lateral extension from above the mental unit and matched with the potential wrinkle line of the lower lip in order to design a unit morphology surrounded by the anterior margin of the depressor labii inferioris muscle. It was elevated as a full-thickness flap composed of the orbicularis oris muscle, skin, and mucosa of the residual lower lip from the bilateral sides, and advanced to the defect. Flap transfer was adjusted by small triangular resection of the skin on the lateral side of the mental unit. The postoperative scar was inconspicuous in all patients and there was no impairment of the mouth opening-closing or articulation functions. This was a relatively simple surgical procedure. A blood supply of the flap was stable, and continuity of the orbicularis oris muscle was reconstructed by transferred the residual lower lip advancement flap from the bilateral sides. The postoperative mouth opening-closing function was sufficient, and dentures could be placed from an early phase in elderly patients. The postoperative scar was consistent with the lip unit morphology, being esthetically superior. This procedure may be applicable for reconstruction of defects approximately 1/3 to 2/3 the width of the lower lip where the mouth angle is preserved.

  13. Short stature Revealing a Pycnodysostosis: A Case Report

    PubMed Central

    Aynaou, Hayat; Skiker, Imane; Latrech, Hanane

    2016-01-01

    Introduction: Pycnodysostosis is a rare genetic disease characterized by osteosclerosis and bone fragility. The clinical aspects are varied including short stature, acro-osteolysis of distal phalanges, and dysplasia of the clavicles. Oral and maxillofacial manifestations of this disease are very clear. The head is usually large, a beaked nose, obtuse mandibular angle, and both maxilla and mandible are hypoplastic. Dental abnormalities are common. We report a case with the typical clinical and radiological characteristics of the Pycnodysostosis associated with a conductive hearing loss, an association rarely reported. Case Presentation: A 12-year-female was admitted in our institute for short stature with a dysmorphic facies for evaluation. The patient reported a history of multiple fractures of the long bones after a trivial fall. On physical examination, she had the following features: short stature, limited mouth opening, short hands and feet with dysplastic nails; frontal and occipital bossing; and hypoplasia of the maxilla and mandible. Examination of the mouth: grooved palate, caries of the teeth, impacted and malposed teeth, persistent deciduous teeth and missing teeth. Laboratory investigations were normal. The radiographic examination showed a generalized increase in the bone density, slight condensation of the skull base and a very open mandibular angle. X-rays showed tapered phalanges with acro-osteolysis of the distal phalanges. A symptomatic treatment was proposed based on fracture prevention, oral hygiene, frequent dental visits and psychiatric support. Conclusion: The clinical and radiological features are the bases for the diagnosis of this disease. It is important to make the diagnosis as early as possible in order to plan the treatment and to provide a better life quality to the patients. PMID:27703936

  14. Latanoprostene Bunod Ophthalmic Solution 0.024%: A Review in Open-Angle Glaucoma and Ocular Hypertension.

    PubMed

    Hoy, Sheridan M

    2018-05-14

    Latanoprostene bunod ophthalmic solution 0.024% (hereafter referred to as latanoprostene bunod 0.024%) [Vyzulta™] is a nitric oxide (NO)-donating prostaglandin F 2α analogue approved in the USA for the reduction of intraocular pressure (IOP) in patients with open-angle glaucoma (OAG) or ocular hypertension. It is thought to lower IOP by increasing aqueous humour outflow through the uveoscleral pathway (mediated by latanoprost acid) and increasing the facility of aqueous humour outflow through the trabecular meshwork pathway (mediated by NO). Results from two multinational, phase III studies (APOLLO and LUNAR) and a pooled analysis of these studies demonstrated the noninferiority of latanoprostene bunod 0.024% to timolol ophthalmic solution 0.5% (hereafter referred to as timolol 0.5%) in terms of IOP-lowering efficacy over 3 months in patients with OAG or ocular hypertension, with the superiority of latanoprostene bunod 0.024% over timolol 0.5% subsequently demonstrated in APOLLO and the pooled analysis. Moreover, there was no apparent loss of IOP-lowering effect in subsequent safety extension periods of up to 9 months. The IOP-lowering efficacy seen in APOLLO and LUNAR was confirmed in a phase III study (JUPITER) in Japanese patients, with IOP reductions observed early (week 4) and maintained over the longer-term (12 months). Latanoprostene bunod 0.024% was well tolerated over up to 12 months in these studies, with most ocular treatment-emergent adverse events (TEAEs) being mild to moderate in severity. Thus, current evidence indicates once-daily latanoprostene bunod 0.024% is an effective and well tolerated treatment option for the reduction of IOP in adults with OAG or ocular hypertension.

  15. Visual disability in newly diagnosed primary open angle glaucoma (POAG) patients in a tertiary hospital in Nigeria.

    PubMed

    Awoyesuku, E A; Ejimadu, C S

    2012-01-01

    Glaucoma remains the second leading cause of blindness worldwide and the highes cause of irreversible blindness worldwide. In N Glaucoma accounts for 16% of blindness and primary open angle glaucoma is the most prevalent clinical type. The aim of this study is to assess the visual disability resulting from glaucoma in newly diagnosed POAG patients in University of Port Harcourt Teaching Hospital. This is a retrospective study of newly diagnosed glaucoma patients referred from the general ophthalmology clinic to the glaucoma clinic over a 12 month period (January-December 2010). All patients had a glaucoma workup includin Snellen distant visual acuity, slit lamp examination, Goldman applanation tonometry, gonioscopy, dilated fundoscopy with +78 diopter lens as well as perimetry. All examinations were carried out by both authors. Patients with other co-morbidities such as cataract and retinal/macular pathologies were excluded from the study. A total of 98 patients were reviewed. The were 34 males and 27 females, giving a male to female ratio of 1.3:1. The average age was 54.2 years and most patients (>80%) were in the 40-59 year age group. Of the 98 patients reviewed, 62.2% had POAG. 30 patients were-blind by distant visual acuity criteria while 45 patients were blind by central visual field criteria. POAG is the most prevalent clinical subtype of glaucoma in Nigeria and sub-Saharan Africa Paucity of symptoms in early stages of the disease at late presentation is a characteristic finding in our clinic environment. Our study showed that POAG in our environment is associated with marked visual disability at the time of presentation.

  16. Identification a novel MYOC gene mutation in a Chinese family with juvenile-onset open angle glaucoma.

    PubMed

    Zhao, Xin; Yang, Chaoshan; Tong, Yi; Zhang, Xiaohui; Xu, Liang; Li, Yang

    2010-08-25

    To describe the clinical and genetic findings in one Chinese family with juvenile-onset open angle glaucoma (JOAG). One family was examined clinically and a follow-up took place 5 years later. After informed consent was obtained, genomic DNA was extracted from the venous blood of all participants. Linkage analysis was performed with three microsatellite markers around the MYOC gene (D1S196, D1S2815, and D1S218) in the family. Mutation screening of all coding exons of MYOC was performed by direct sequencing of PCR-amplified DNA fragments and restriction fragment length polymorphism (RFLP) analysis. Bioinformatics analysis by the Garnier-Osguthorpe-Robson (GOR) method predicted the effects of variants detected on secondary structures of the MYOC protein. Clinical examination and pedigree analysis revealed a three- generation family with seven members diagnosed with JOAG, three with ocular hypertension, and five normal individuals. Through genotyping, the pedigree showed a linkage to the MYOC on chromosome 1q24-25. Mutation screening of MYOC in this family revealed an A-->T transition at position 1348 (p. N450Y) of the cDNA sequence. This missense mutation co-segregated with the disease phenotype of the family, but was not found in 100 normal controls. Secondary structure prediction of the p.N450Y by the GOR method revealed the replacement of a coil with a beta sheet at the amino acid 447. Early onset JOAG, with incomplete penetrance, is consistent with a novel mutation in MYOC. The finding provides pre-symptomatic molecular diagnosis for the members of this family and is useful for further genetic consultation.

  17. [21st century management of glaucoma].

    PubMed

    Tsukahara, Shigeo

    2003-12-01

    According to a recent epidemiological study done in Japan, 2 or 3 million Japanese people are thought to be suffering from glaucoma, and 70-80% of them have not been examined or diagnosed by ophthalmologists. Therefore, the problem is how to find these untreated and undiagnosed people. At present, treatment of glaucoma continues to be directed at lowering intraocular pressure to prevent progression of glaucomatous optic neuropathy. However, theoretically, there are three stages in the prevention of progression of glaucoma. In the first stage, diagnosis of glaucoma can be done by genetic examination, before occurrence of glaucoma. The MYOCILIN/trabecular meshwork-inducible glucocorticoid response gene and the optineurin gene were identified as the genes that cause open angle glaucoma. Although some Japanese patients have sequence changes in the myocilin gene, there are no apparent specific mutations in Japanese glaucoma patients, in the MYOCILIN/TIGR and optineurin genes. Secondary glaucoma such as steroid glaucoma, induced by allergic diseases, and neovascular glaucoma, induced by retinal circulatory insufficiency, are preventable by improving the causal diseases, diabetes and hypertension. The education of doctors and laymen is important to reduce the occurrence of diabetes, and hypertension to prevent diabetic retinopathy, and retinal vessel occlusion. The second stage in preventing progression of glaucoma is to find the disease as early as possible. In Japan, a physical examination system is in place for everybody over 40 years old, in companies and local districts. Therefore, ocular examination, specially non-mydriatic fundus photographs should be taken in these examinations, and the film should be evaluated by an ophthalmologist, to search for retinal and optic disc abnormalities. Primary open angle glaucoma can be detected through this system in early stages. In primary angle closure glaucoma, instruments for estimating anterior chamber rapidly and accurately are necessary for the diagnosis. There is a special machine which can be handled easily, safely, and economically for detecting angle closure glaucoma, has been developed by Yamanashi University. This machine might help to reduce the number of angle closure glaucoma patients in the world. In the near future, a glaucoma network system should be put in place all over Japan. This organization consists of central headquarter and local central office. Most hospitals and private offices will belong to a local central office, and several glaucoma specialists will work in central and local offices. All glaucoma patients will be registered in local glaucoma office. The information on glaucoma patients will be communicated in the system the through light fiber cables or a satellite system. The patients can ask about their own disease through this glaucoma center system. In the third stage of glaucoma prevention, progression of glaucomatous optic neuropathy is retarded by conventional IOP lowering treatment or neuroprotective drugs. This stage compromises rehabilitation of visual function, implant of artificial visual systems, and regeneration of retinal ganglion cells(RGC). The disturbances of axonal flow in guinea pig optic nerve fibers was demonstrated electromicroscopically by quick-freeze, deep-etching method and, the decrease in numbers of motor proteins like "Kinesin" "Dynein" and "MAP-1" was shown in guinea pig eyes with elevated intraocular pressure by immunohistochemistry. Retinal glanglion cells have been isolated and new findings have been reported using this RGC culture system. Therefore, new neuroprotective drugs will be developed through this culture system.

  18. A dynamic study of the anterior cruciate ligament of the knee using an open MRI.

    PubMed

    Guenoun, Daphne; Vaccaro, Julien; Le Corroller, Thomas; Barral, Pierre-Antoine; Lagier, Aude; Pauly, Vanessa; Coquart, Benjamin; Coste, Joel; Champsaur, Pierre

    2017-03-01

    Recent anatomical and radiological studies of the anterior cruciate ligament (ACL) suggest the ACL length and orientation change during knee flexion, and an open MRI sequencing during knee flexion enables a dynamic ACL analysis. This study's goal is to describe a normal ACL using a 1T open MRI and, in particular, variations in length and insertion angles at different degrees of flexion. Twenty-one volunteers with clinically healthy knees received a dynamic MRI with their knees in hyperextension, neutral position, and flexed at 45° and 90° angles. For each position, two radiologists measured the ACL lengths and angles of the proximal insertion between the ACL's anterior edge and the roof of the inter-condylar notch. Additionally, we measured the ACL's and the tibial plateau's distal angle insertion between their anterior edges and then compared these with the nonparametric Wilcoxon test. The ACL had a significant extension between the 90° flexion and all other positions (hyperextension: 31.75 ± 2.5 mm, neutral position: 32.5 ± 2.6 mm, 45°: 35.6 ± 1.6 mm, 90°: 35.6 ± 1.6 mm). There was also a significant increase of the angle insertion between the proximal 90° flexion and all other positions, as well as between hyperextension and bending to 45° (hyperextension: 2.45° ± 3.7°, neutral: 13.4° ± 9.7°, 45°: 33 25 ± 9.3, 90: 51.85° ± 9.3°). Additionally, there is a significant increase in the distal angle insertion for all positions (hyperextension: 133.2° ± 5.4°, neutral position: 134.95° ± 4.4°, 45°: 138.35° ± 5.9°, 90°: 149.15° ± 8.6°). Our study is the first to exhibit that a dynamic MRI has a significant ACL extension in vivo during bending. This concept opens the way for further studies to improve the diagnosis of traumatic ACL injuries using a dynamic MRI.

  19. A method to measure internal contact angle in opaque systems by magnetic resonance imaging.

    PubMed

    Zhu, Weiqin; Tian, Ye; Gao, Xuefeng; Jiang, Lei

    2013-07-23

    Internal contact angle is an important parameter for internal wettability characterization. However, due to the limitation of optical imaging, methods available for contact angle measurement are only suitable for transparent or open systems. For most of the practical situations that require contact angle measurement in opaque or enclosed systems, the traditional methods are not effective. Based upon the requirement, a method suitable for contact angle measurement in nontransparent systems is developed by employing MRI technology. In the Article, the method is demonstrated by measuring internal contact angles in opaque cylindrical tubes. It proves that the method also shows great feasibility in transparent situations and opaque capillary systems. By using the method, contact angle in opaque systems could be measured successfully, which is significant in understanding the wetting behaviors in nontransparent systems and calculating interfacial parameters in enclosed systems.

  20. [Sinus tarsi approach combined with medial distraction technique for treatment of intra-articular calcaneus fractures].

    PubMed

    Zhou, Haichao; Ren, Haoyang; Li, Bing; Yu, Tao; Yang, Yunfeng

    2016-07-08

    ?To discuss the effectiveness of limited open reduction via sinus tarsi approach using medial distraction technique in the treatment of intra-articular calcaneus fractures by comparing with open reduction and internal fixation via extensile L-shaped incision. ?A retrospective analysis was made on the clinical data of 21 patients with intra-articular calcaneus fractures treated by sinus tarsi approach combined with medial distraction technique between April 2013 and November 2014 (minimally invasive group), and 32 patients treated by extensile L-shaped incision approach between June 2012 and September 2014 (extensile incision group). No significant difference was found in gender, age, injury pattern, fracture classification, time from injury to operation, preoperative Böhler angle, Gissane angle, calcaneal varus angle, the ankle and hind-foot score of American Orthopaedic Foot and Ankle Society (AOFAS), and visual analogue scale (VAS) score between 2 groups (P>0.05), which was comparable. The operation time, wound complications, and bone healing time were recorded. The postoperative function was also evaluated by AOFAS score and VAS score. The pre-and post-operative Böhler angle, Gissane angle, and calcaneal varus angle were measured on the X-ray films, and the corrective angle was calculated. ?Sixteen patients were followed up 6-18 months (mean, 11.5 months) in the minimally invasive group, and 23 patients for 6-24 months (mean, 13.5 months) in the extensile incision group. Difference was not significant in operation time between 2 groups (t=0.929, P=0.796). No complication occurred in the minimally invasive group; partial skin flap necrosis occurred in 3 cases of the extensile incision group, was cured after dressing change. There was no loosening of implants or reduction loss in 2 groups at last follow-up. Subtalar joint stiffness occurred in 1 case of the minimally invasive group and 4 cases of the extensile incision group, and 1 patient had discomfort for the implants in the extensile incision group. The bone healing time was (9.9±0.8) weeks in the minimally invasive group, and was (10.1±0.7) weeks in the extensile incision group, showing no significant difference (t=0.613, P=0.845 ). Böhler angle, Gissane angle, calcaneal varus angle, AOFAS score, and VAS score were significantly improved at last follow-up when compared with preoperative values in 2 groups (P<0.05), but there was no significant difference between 2 groups (P>0.05), and the corrective value of angle showed no significant difference between 2 groups (P>0.05). ?Limited open reduction via sinus tarsi approach for intra-articular calcaneus fractures could reduce the incidence of wound complications effectively. Meanwhile, the medial distraction technique is helpful to correct the heel varus deformity.

  1. Early career researchers want Open Science.

    PubMed

    Farnham, Andrea; Kurz, Christoph; Öztürk, Mehmet Ali; Solbiati, Monica; Myllyntaus, Oona; Meekes, Jordy; Pham, Tra My; Paz, Clara; Langiewicz, Magda; Andrews, Sophie; Kanninen, Liisa; Agbemabiese, Chantal; Guler, Arzu Tugce; Durieux, Jeffrey; Jasim, Sarah; Viessmann, Olivia; Frattini, Stefano; Yembergenova, Danagul; Benito, Carla Marin; Porte, Marion; Grangeray-Vilmint, Anaïs; Curiel, Rafael Prieto; Rehncrona, Carin; Malas, Tareq; Esposito, Flavia; Hettne, Kristina

    2017-11-15

    Open Science is encouraged by the European Union and many other political and scientific institutions. However, scientific practice is proving slow to change. We propose, as early career researchers, that it is our task to change scientific research into open scientific research and commit to Open Science principles.

  2. Neurovascular structures of the mandibular angle and condyle: a comprehensive anatomical review.

    PubMed

    Yang, Hun-Mu; Won, Sung-Yoon; Kim, Hee-Jin; Hu, Kyung-Seok

    2015-11-01

    Various surgical interventions including esthetic surgery, salivary gland excision, and open reduction of fracture have been performed in the area around the mandibular angle and condyle. This study aimed to comprehensively review the anatomy of the neurovascular structures on the angle and condyle with recent anatomic and clinical research. We provide detailed information about the branching and distributing patterns of the neurovascular structures at the mandibular angle and condyle, with reported data of measurements and proportions from previous anatomical and clinical research. Our report should serve to help practitioners gain a better understanding of the area in order or reduce potential complications during local procedures. Reckless manipulation during mandibular angle reduction could mutilate arterial branches, not only from the facial artery, but also from the external carotid artery. The transverse facial artery and superficial temporal artery could be damaged during approach and incision in the condylar area. The marginal mandibular branch of the facial nerve can be easily damaged during submandibular gland excision or facial rejuvenation treatment. The main trunk of the facial nerve and its upper and lower distinct divisions have been damaged during parotidectomy, rhytidectomy, and open reductions of condylar fractures. By revisiting the information in the present study, surgeons will be able to more accurately prevent procedure-related complications, such as iatrogenic vascular accidents on the mandibular angle and condyle, complete and partial facial palsy, gustatory sweating (Frey syndrome), and traumatic neuroma after parotidectomy.

  3. Trabecular Meshwork Height in Primary Open-Angle Glaucoma Versus Primary Angle-Closure Glaucoma.

    PubMed

    Masis, Marisse; Chen, Rebecca; Porco, Travis; Lin, Shan C

    2017-11-01

    To determine if trabecular meshwork (TM) height differs between primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG) eyes. Prospective, cross-sectional clinical study. Adult patients were consecutively recruited from glaucoma clinics at the University of California, San Francisco, from January 2012 to July 2015. Images were obtained from spectral-domain optical coherence tomography (Cirrus OCT; Carl Zeiss Meditec, Inc, Dublin, California, USA). Univariate and multivariate linear mixed models comparing TM height and glaucoma type were performed to assess the relationship between TM height and glaucoma subtype. Mixed-effects regression was used to adjust for the use of both eyes in some subjects. The study included 260 eyes from 161 subjects, composed of 61 men and 100 women. Mean age was 70 years (SD 11.77). There were 199 eyes (123 patients) in the POAG group and 61 eyes (38 patients) in the PACG group. Mean TM heights in the POAG and PACG groups were 812 ± 13 μm and 732 ± 27 μm, respectively, and the difference was significant in univariate analysis (P = .004) and in multivariate analysis (β = -88.7 [24.05-153.5]; P = .008). In this clinic-based population, trabecular meshwork height is shorter in PACG patients compared to POAG patients. This finding may provide insight into the pathophysiology of angle closure and provide assistance in future diagnosis, prevention, and management of the angle-closure spectrum of disorders. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. 16 CFR 1500.43 - Method of test for flashpoint of volatile flammable materials by Tagliabue open-cup apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... inches in length, with a right-angle bend 1/2-inch from each end. This wire is placed snugly in holes... form a top when shield is open). The interior of the draft shield shall be painted a flat black...

  5. 16 CFR 1500.43 - Method of test for flashpoint of volatile flammable materials by Tagliabue open-cup apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... inches in length, with a right-angle bend 1/2-inch from each end. This wire is placed snugly in holes... form a top when shield is open). The interior of the draft shield shall be painted a flat black...

  6. Prevalence of comorbid retinal disease in patients with glaucoma at an academic medical center.

    PubMed

    Griffith, Joseph F; Goldberg, Jeffrey L

    2015-01-01

    Patients with various retinal diseases and patients who have undergone retinal procedures and surgeries have an increased risk of developing ocular hypertension and glaucoma. Little is known about the epidemiology of comorbid retinal diseases in glaucoma patients. This study evaluated the prevalence of retinal comorbidities in a population of patients with five types of glaucoma. A longitudinal, retrospective study was conducted using International Classification of Disease (ICD-9) billing records from 2003 to 2010 at an academic medical center. Patients were classified as having primary open-angle glaucoma (POAG), low tension open-angle glaucoma (NTG), pigmentary open-angle glaucoma, chronic-angle closure glaucoma (CACG), or pseudoexfoliation glaucoma (PXG) if they had at least three clinic visits with the same ICD-9 code. Patients were classified as having a retinal comorbidity if they had two visits with the same code. Variables were analyzed with the independent t-test, χ (2) test, analysis of variance, or Fisher's exact test. A total of 5,154 patients had glaucoma, and 14.8% of these had a retinal comorbidity. The prevalence of comorbid retinal disease was higher in patients with POAG (15.7%) than in those with NTG (10.7%), PXG (10.1%), or pigmentary open-angle glaucoma (3.7%; P<0.05). Two hundred and two patients had diabetic retinopathy, with POAG patients (4.5%) having a higher prevalence than those with CACG (1.4%) or PXG (0.6%; P<0.001). There were 297 patients who had macular degeneration and both POAG (2.0%) and PXG patients (2.9%) had a higher prevalence of nonexudative macular degeneration than those with CACG (0%; P<0.01). Patients with comorbid retinal disease had a higher prevalence of blindness and low vision than those without comorbid retinal disease (1.97% versus 1.02%, P=0.02). The high prevalence of comorbid retinal disease and the nearly twofold increase in blindness and low vision in this population demonstrate the need for ophthalmologists to determine if patients have multiple etiologies for their vision loss. The higher prevalence of certain retinal diseases in POAG patients may reflect common pathophysiological processes that warrant further investigation.

  7. SU-G-TeP4-03: A Multileaf Collimator Calibration and Quality Assurance Technique Using An Electronic Portal Imaging Device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lebron, S; Yan, G; Li, J

    2016-06-15

    Purpose: To develop an accurate and quick multileaf collimator (MLC) calibration and quality assurance technique using an electronic portal imaging device (EPID) Methods: The MLC models used include the MLCi and Agility (Elekta Ltd). This technique consists of two 22(L)x10(W) cm{sup 2} fields with 0{sup 0} and 180{sup 0} collimator angles centered to an offset EPID. The MLC opening is estimated by calculating the profile at the image’s center in the image’s horizontal direction. Scans in the image’s vertical direction were calculated every 20 pixels in the inner 70% of estimated MLC opening. The profiles’ edges were fitted with linearmore » equations to determine the image’s rotation angle. Then, crossline profiles were scanned at the center of each leaf taking into account the leaf’s width at isocenter and the rotation angle. The profiles’ edges determine the location of the leaves’ edges and these were subtracted from the reference leaf’s position in order to determine the relative leaf offsets. The edge location of all profiles was determined by using the parameterized gradient of the penumbra region. The technique was tested against an established diode array-based method, and for different MLC systems, patterns, gantry angles, days, energies, beam modalities and MLC openings. Results: The differences between the proposed and established methods were 0.26±0.19mm. The leaf offsets’ deviation was <0.3mm (5 months period). For pattern fields, the differences between predetermined and calculated offsets were 0.18±0.18mm. The leaf offset deviation of measurements with different energies and MLC openings were <0.1mm and <0.3mm, respectively. The differences between offsets of FF and FFF beams were 0.01±0.02mm (<0.07mm). The differences between the offsets at different gantry angles were 0.08±0.15mm. Conclusion: The proposed method proved to be accurate and efficient in calculating the relative leaf offsets. Parameterized field edge is essential to obtain accurate result by eliminating the noise from EPID.« less

  8. Biomechanical stability of novel mechanically adapted open-porous titanium scaffolds in metatarsal bone defects of sheep.

    PubMed

    Wieding, Jan; Lindner, Tobias; Bergschmidt, Philipp; Bader, Rainer

    2015-04-01

    Open-porous titanium scaffolds for large segmental bone defects offer advantages like early weight-bearing and limited risk of implant failure. The objective of this experimental study was to determine the biomechanical behavior of novel open-porous titanium scaffolds with mechanical-adapted properties in vivo. Two types of the custom-made, open-porous scaffolds made of Ti6Al4V (Young's modulus: 6-8 GPa and different pore sizes) were implanted into a 20 mm segmental defect in the mid-diaphysis of the metatarsus of sheep, and were stabilized with an osteosynthesis plate. After 12 and 24 weeks postoperatively, torsional testing was performed on the implanted bone and compared to the contralateral non-treated side. Maximum torque, maximum angle, torsional stiffness, fracture energy, shear modulus and shear stress were investigated. Furthermore, bone mineral density (BMD) of the newly formed bone was determined. Mechanical loading capabilities for both scaffolds were similar and about 50% after 12 weeks (e.g., max. torque of approximately 20 Nm). A further increase after 24 weeks was found for most of the investigated parameters. Results for torsional stiffness and shear modulus as well as bone formation depended on the type of scaffold. Increased BMD after 24 weeks was found for one scaffold type but remained constant for the other one. The present data showed the capability of mechanically adapted open-porous titanium scaffolds to function as bone scaffolds for large segmental defects and the influence of the scaffold's stiffness. A further increase in the biomechanical stability can be assumed for longer observation periods of greater than six months. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Precision determination of electron scattering angle by differential nuclear recoil energy method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liyanage, N.; Saenboonruang, K.

    2015-12-01

    The accurate determination of the scattered electron angle is crucial to electron scattering experiments, both with open-geometry large-acceptance spectrometers and ones with dipole-type magnetic spectrometers for electron detection. In particular, for small central-angle experiments using dipole-type magnetic spectrometers, in which surveys are used to measure the spectrometer angle with respect to the primary electron beam, the importance of the scattering angle determination is emphasized. However, given the complexities of large experiments and spectrometers, the accuracy of such surveys is limited and insufficient to meet demands of some experiments. In this article, we present a new technique for determination of themore » electron scattering angle based on an accurate measurement of the primary beam energy and the principle of differential nuclear recoil. This technique was used to determine the scattering angle for several experiments carried out at the Experimental Hall A, Jefferson Lab. Results have shown that the new technique greatly improved the accuracy of the angle determination compared to surveys.« less

  10. Precision Determination of Electron Scattering Angle by Differential Nuclear Recoil Energy Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liyanage, Nilanga; Saenboonruang, Kiadtisak

    2015-09-01

    The accurate determination of the scattered electron angle is crucial to electron scattering experiments, both with open-geometry large-acceptance spectrometers and ones with dipole-type magnetic spectrometers for electron detection. In particular, for small central-angle experiments using dipole-type magnetic spectrometers, in which surveys are used to measure the spectrometer angle with respect to the primary electron beam, the importance of the scattering angle determination is emphasized. However, given the complexities of large experiments and spectrometers, the accuracy of such surveys is limited and insufficient to meet demands of some experiments. In this article, we present a new technique for determination of themore » electron scattering angle based on an accurate measurement of the primary beam energy and the principle of differential nuclear recoil. This technique was used to determine the scattering angle for several experiments carried out at the Experimental Hall A, Jefferson Lab. Results have shown that the new technique greatly improved the accuracy of the angle determination compared to surveys.« less

  11. Characteristics of a wind-actuated aerodynamic braking device for high-speed trains

    NASA Astrophysics Data System (ADS)

    Takami, H.; Maekawa, H.

    2017-04-01

    To shorten the stopping distance of the high speed trains in case of emergency, we developed a small-sized aerodynamic braking unit without use of the friction between a rail and a wheel. The developed device could actuate a pair of two drag panels with a travelling wind. However, after the drag panel fully opened, vibrational movements of the drag panel characterized by its slight flutter were repeated. In this study, to stabilize the opened panel, matters pertaining to the angle of attack with respect to the drag panel and pertaining to the arrangement of the two panels were examined by a wind tunnel experiment using a scale model. As a result, to stabilize the opened panel and to keep the good performance of the braking device, it is found out that an angle of attack of 75 to 80 degrees is suitable provided that the interval of the two panels is narrow enough.

  12. Spectral Analysis: From Additive Perspective to Multiplicative Perspective

    NASA Astrophysics Data System (ADS)

    Wu, Z.

    2017-12-01

    The early usage of trigonometric functions can be traced back to at least 17th century BC. It was Bhaskara II of the 12th century CE who first proved the mathematical equivalence between the sum of two trigonometric functions of any given angles and the product of two trigonometric functions of related angles, which has been taught these days in middle school classroom. The additive perspective of trigonometric functions led to the development of the Fourier transform that is used to express any functions as the sum of a set of trigonometric functions and opened a new mathematical field called harmonic analysis. Unfortunately, Fourier's sum cannot directly express nonlinear interactions between trigonometric components of different periods, and thereby lacking the capability of quantifying nonlinear interactions in dynamical systems. In this talk, the speaker will introduce the Huang transform and Holo-spectrum which were pioneered by Norden Huang and emphasizes the multiplicative perspective of trigonometric functions in expressing any function. Holo-spectrum is a multi-dimensional spectral expression of a time series that explicitly identifies the interactions among different scales and quantifies nonlinear interactions hidden in a time series. Along with this introduction, the developing concepts of physical, rather than mathematical, analysis of data will be explained. Various enlightening applications of Holo-spectrum analysis in atmospheric and climate studies will also be presented.

  13. Diagnosis and conservative treatment of skeletal Class III malocclusion with anterior crossbite and asymmetric maxillary crowding.

    PubMed

    Tseng, Linda L Y; Chang, Chris H; Roberts, W Eugene

    2016-04-01

    A man, aged 28 years 9 months, came for an orthodontic consultation for a skeletal Class III malocclusion (ANB angle, -3°) with a modest asymmetric Class II and Class III molar relationship, complicated by an anterior crossbite, a deepbite, and 12 mm of asymmetric maxillary crowding. Despite the severity of the malocclusion (Discrepancy Index, 37), the patient desired noninvasive camouflage treatment. The 3-Ring diagnosis showed that treatment without extractions or orthognathic surgery was a viable approach. Arch length analysis indicated that differential interproximal enamel reduction could resolve the crowding and midline discrepancy, but a miniscrew in the infrazygomatic crest was needed to retract the right buccal segment. The patient accepted the complex, staged treatment plan with the understanding that it would require about 3.5 years. Fixed appliance treatment with passive self-ligating brackets, early light short elastics, bite turbos, interproximal enamel reduction, and infrazygomatic crest retraction opened the vertical dimension of the occlusion, improved the ANB angle by 2°, and achieved excellent alignment, as evidenced by a Cast Radiograph Evaluation score of 28 and a Pink and White dental esthetic score of 3. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  14. Phase III Early Restoration Meeting | NOAA Gulf Spill Restoration

    Science.gov Websites

    Louisiana Mississippi Texas Region-wide Open Ocean Data Media & News Publications Press Releases Story programmatic approach to early restoration planning for Phase III and future early restoration plans. Open

  15. Phase III Early Restoration Meeting - Corpus Christi, TX | NOAA Gulf Spill

    Science.gov Websites

    Areas Alabama Florida Louisiana Mississippi Texas Region-wide Open Ocean Data Media & News programmatic approach to early restoration planning for Phase III and future early restoration plans. Open

  16. Phase III Early Restoration Meeting - Pensacola, FL (rescheduled) | NOAA

    Science.gov Websites

    Restoration Areas Alabama Florida Louisiana Mississippi Texas Region-wide Open Ocean Data Media & News programmatic approach to early restoration planning for Phase III and future early restoration plans. Open

  17. A predictive factor for acquiring an ideal lower limb realignment after opening-wedge high tibial osteotomy.

    PubMed

    Bito, Haruhiko; Takeuchi, Ryohei; Kumagai, Ken; Aratake, Masato; Saito, Izumi; Hayashi, Riku; Sasaki, Yohei; Aota, Yoichi; Saito, Tomoyuki

    2009-04-01

    Obtaining a correct postoperative limb alignment is an important factor in achieving a successful clinical outcome after an opening-wedge high tibial osteotomy (OWHTO). To better predict some of the aspects that impact upon the clinical outcomes following this procedure, including postoperative correction loss and over correction, we examined the changes in the frontal plane of the lower limb in a cohort of patients who had undergone OWHTO using radiography. Forty-two knees from 33 patients (23 cases of osteoarthritis and 10 of osteonecrosis) underwent a valgus realignment OWHTO procedure and were radiographically assessed for changes that occurred pre- and post-surgery. The mean femorotibial angle (FTA) was found to be 182.1 +/- 2.0 degrees (12 +/- 2.0 anatomical varus angulation) preoperatively and 169.6 +/- 2.4 degrees (10.4 +/- 2.4 anatomical valgus angulation) postoperatively. These measurements thus revealed significant changes in the weight bearing line ratio (WBL), femoral axis angle (FA), tibial axis angle (TA), tibia plateau angle (TP), tibia vara angle (TV) and talar tilt angle (TT) following OWHTO. In contrast, no significant change was found in the weight bearing line angle (WBLA) after these treatments. To assess the relationship between the correction angle and these indexes, 42 knees were divided into the following three groups according to the postoperative FTA; a normal correction group (168 degrees < or = FTA < or = 172 degrees ), an over-correction group (FTA < 168 degrees ), and an under-correction group (FTA > 172 degrees ). There were significant differences in the delta angle [DA; calculated as (pre FTA - post FTA) - (pre TV - post TV)] among each group of patients. Our results thus indicate a negative correlation between the DA and preoperative TA (R(2) = 0.148, p < 0.05). Hence, given that the correction errors in our patients appear to negatively correlate with the preoperative TA, postoperative malalignments are likely to be predictable prior to surgery.

  18. Stage of visual field loss and age at diagnosis in 1988 patients with different glaucomas: implications for glaucoma screening and driving ability.

    PubMed

    Gramer, Gwendolyn; Gramer, Eugen

    2018-04-01

    To compare stage of visual field loss (VFL) and age at diagnosis between patients with different types of glaucoma with regard to glaucoma screening and driving ability. In a cross-sectional study of 1988 consecutive patients with different types of glaucoma VFL at diagnosis and age at diagnosis were assessed. Patients with binocular advanced or severe VFL were classified unable, patients with no VFL in one eye and VFL I-V (Aulhorn classification) in the other eye able, all other constellations questionably able to drive. There were significant differences in age at diagnosis between different glaucomas and between patients with different stages of VFL at diagnosis. Age-related assessment of VFL at diagnosis in normal tension glaucoma (NTG) compared to primary open-angle glaucoma (POAG) showed that NTG is not a disease of the elderly but a disease with late diagnosis at severe VFL. In POAG a solely age-related glaucoma screening, e.g. from the age of 50 years, does not sufficiently lead to diagnosis at an early stage of the disease. In POAG solely based on binocular VFL 11.5% of patients were judged unable, 29.2% questionably able to drive, in NTG 19.6%/43.1%, pigmentary glaucoma 16%/22%, pseudoexfoliation glaucoma 9.1%/16.7%, and in primary angle-closure glaucoma 14.6%/30%. Depending on type of glaucoma more than 50% of patients require counselling regarding safe driving as part of clinical care. A disease-specific, age-related perimetric examination considering additional risk factors like family history of glaucoma is essential for early detection of glaucoma and road safety.

  19. An Exploratory Investigation of the Role of Openness in Relationship Quality among Emerging Adult Chinese Couples

    PubMed Central

    Zhou, Yixin; Wang, Kexin; Chen, Shuang; Zhang, Jianxin; Zhou, Mingjie

    2017-01-01

    This study tested emerging adult couples’ openness and its fit effect on their romantic relationship quality using quadratic polynomial regression and response surface analysis. Participants were 260 emerging adult dyads. Both dyads’ openness and relationship quality were measured. The result showed that (1) female and male openness contribute differently to relationship quality; (2) couples with similar high openness could experience better relationship quality than those with similar low openness traits; and (3) when dyadic openness is dissimilar, it is better to be either relatively high or relatively low than to be moderate. These findings highlight the role of openness in emerging adults’ romantic relationships from a dyadic angle. PMID:28360875

  20. A platform for dynamic simulation and control of movement based on OpenSim and MATLAB.

    PubMed

    Mansouri, Misagh; Reinbolt, Jeffrey A

    2012-05-11

    Numerical simulations play an important role in solving complex engineering problems and have the potential to revolutionize medical decision making and treatment strategies. In this paper, we combine the rapid model-based design, control systems and powerful numerical method strengths of MATLAB/Simulink with the simulation and human movement dynamics strengths of OpenSim by developing a new interface between the two software tools. OpenSim is integrated with Simulink using the MATLAB S-function mechanism, and the interface is demonstrated using both open-loop and closed-loop control systems. While the open-loop system uses MATLAB/Simulink to separately reproduce the OpenSim Forward Dynamics Tool, the closed-loop system adds the unique feature of feedback control to OpenSim, which is necessary for most human movement simulations. An arm model example was successfully used in both open-loop and closed-loop cases. For the open-loop case, the simulation reproduced results from the OpenSim Forward Dynamics Tool with root mean square (RMS) differences of 0.03° for the shoulder elevation angle and 0.06° for the elbow flexion angle. MATLAB's variable step-size integrator reduced the time required to generate the forward dynamic simulation from 7.1s (OpenSim) to 2.9s (MATLAB). For the closed-loop case, a proportional-integral-derivative controller was used to successfully balance a pole on model's hand despite random force disturbances on the pole. The new interface presented here not only integrates the OpenSim and MATLAB/Simulink software tools, but also will allow neuroscientists, physiologists, biomechanists, and physical therapists to adapt and generate new solutions as treatments for musculoskeletal conditions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. A platform for dynamic simulation and control of movement based on OpenSim and MATLAB

    PubMed Central

    Mansouri, Misagh; Reinbolt, Jeffrey A.

    2013-01-01

    Numerical simulations play an important role in solving complex engineering problems and have the potential to revolutionize medical decision making and treatment strategies. In this paper, we combine the rapid model-based design, control systems and powerful numerical method strengths of MATLAB/Simulink with the simulation and human movement dynamics strengths of OpenSim by developing a new interface between the two software tools. OpenSim is integrated with Simulink using the MATLAB S-function mechanism, and the interface is demonstrated using both open-loop and closed-loop control systems. While the open-loop system uses MATLAB/Simulink to separately reproduce the OpenSim Forward Dynamics Tool, the closed-loop system adds the unique feature of feedback control to OpenSim, which is necessary for most human movement simulations. An arm model example was successfully used in both open-loop and closed-loop cases. For the open-loop case, the simulation reproduced results from the OpenSim Forward Dynamics Tool with root mean square (RMS) differences of 0.03° for the shoulder elevation angle and 0.06° for the elbow flexion angle. MATLAB’s variable step-size integrator reduced the time required to generate the forward dynamic simulation from 7.1 s (OpenSim) to 2.9 s (MATLAB). For the closed-loop case, a proportional–integral–derivative controller was used to successfully balance a pole on model’s hand despite random force disturbances on the pole. The new interface presented here not only integrates the OpenSim and MATLAB/Simulink software tools, but also will allow neuroscientists, physiologists, biomechanists, and physical therapists to adapt and generate new solutions as treatments for musculoskeletal conditions. PMID:22464351

  2. [The short nose].

    PubMed

    Levet, Y

    2014-12-01

    Short noses are not only depending on the length of the dorsum, but also if there is a saddle deformity, or a too lower situation of the fronto-nasal angle, or an open naso-labial angle or a rim retraction. All the cases are treated, often with the help of cartilage grafts and with a closed approach. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  3. 3. Elevation view of entire midsection using ultrawide angle lens. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Elevation view of entire midsection using ultrawide angle lens. Note opened south doors and closed north doors. The following photo WA-203-C-4 is similar except the camera position was moved right to include the slope of the south end. - Puget Sound Naval Shipyard, Munitions Storage Bunker, Naval Ammunitions Depot, South of Campbell Trail, Bremerton, Kitsap County, WA

  4. Colliding Stellar Winds Structure and X-ray Emission

    NASA Astrophysics Data System (ADS)

    Pittard, J. M.; Dawson, B.

    2018-04-01

    We investigate the structure and X-ray emission from the colliding stellar winds in massive star binaries. We find that the opening angle of the contact discontinuity (CD) is overestimated by several formulae in the literature at very small values of the wind momentum ratio, η. We find also that the shocks in the primary (dominant) and secondary winds flare by ≈20° compared to the CD, and that the entire secondary wind is shocked when η ≲ 0.02. Analytical expressions for the opening angles of the shocks, and the fraction of each wind that is shocked, are provided. We find that the X-ray luminosity Lx∝η, and that the spectrum softens slightly as η decreases.

  5. Efficiency of geometric designs of flexible solar panels: mathematical simulation

    NASA Astrophysics Data System (ADS)

    Marciniak, Malgorzata; Hassebo, Yasser; Enriquez-Torres, Delfino; Serey-Roman, Maria Ignacia

    2017-09-01

    The purpose of this study is to analyze various surfaces of flexible solar panels and compare them to the traditional at panels mathematically. We evaluated the efficiency based on the integral formulas that involve flux. We performed calculations for flat panels with different positions, a cylindrical panel, conical panels with various opening angles and segments of a spherical panel. Our results indicate that the best efficiency per unit area belongs to particular segments of spherically-shaped panels. In addition, we calculated the optimal opening angle of a cone-shaped panel that maximizes the annual accumulation of the sun radiation per unit area. The considered shapes are presented below with a suggestion for connections of the cells.

  6. Phase III Early Restoration Meeting - Lake Charles, LA | NOAA Gulf Spill

    Science.gov Websites

    Areas Alabama Florida Louisiana Mississippi Texas Region-wide Open Ocean Data Media & News early restoration planning for Phase III and future early restoration plans. Open House: 5:30pm Public

  7. Acoustic metamaterials with broadband and wide-angle impedance matching

    NASA Astrophysics Data System (ADS)

    Liu, Chenkai; Luo, Jie; Lai, Yun

    2018-04-01

    We propose a general approach to design broadband and wide-angle impedance-matched acoustic metamaterials. Such an unusual acoustic impedance matching characteristic can be well explained by using a spatially dispersive effective medium theory. For demonstrations, we used silicone rubber, which has a huge impedance contrast with water, to design one- and two-dimensional acoustic structures which are almost perfectly impedance matched to water for a wide range of incident angles and in a broad frequency band. Our work opens up an approach to realize extraordinary acoustic impedance matching properties via metamaterial-design techniques.

  8. Assessing the impacts of canopy openness and flight parameters on detecting a sub-canopy tropical invasive plant using a small unmanned aerial system

    NASA Astrophysics Data System (ADS)

    Perroy, Ryan L.; Sullivan, Timo; Stephenson, Nathan

    2017-03-01

    Small unmanned aerial systems (sUAS) have great potential to facilitate the early detection and management of invasive plants. Here we show how very high-resolution optical imagery, collected from small consumer-grade multirotor UAS platform at altitudes of 30-120 m above ground level (agl), can be used to detect individual miconia (Miconia calvescens) plants in a highly invaded tropical rainforest environment on the island of Hawai'i. The central aim of this research was to determine how overstory vegetation cover, imagery resolution, and camera look-angle impact the aerial detection of known individual miconia plants. For our finest resolution imagery (1.37 cm ground sampling distance collected at 30 m agl), we obtained a 100% detection rate for sub-canopy plants with above-crown openness values >40% and a 69% detection rate for those with >20% openness. We were unable to detect any plants with <10% above crown openness. Detection rates progressively declined with coarser spatial resolution imagery, ending in a 0% detection rate for the 120 m agl flights (ground sampling distance of 5.31 cm). The addition of forward-looking oblique imagery improved detection rates for plants below overstory vegetation, though this effect decreased with increasing flight altitude. While dense overstory canopy cover, limited flight times, and visual line of sight regulations present formidable obstacles for detecting miconia and other invasive plant species, we show that sUAS platforms carrying optical sensors can be an effective component of an integrated management plan within challenging subcanopy forest environments.

  9. Proximal opening wedge osteotomy with wedge-plate fixation compared with proximal chevron osteotomy for the treatment of hallux valgus: a prospective, randomized study.

    PubMed

    Glazebrook, Mark; Copithorne, Peter; Boyd, Gordon; Daniels, Timothy; Lalonde, Karl-André; Francis, Patricia; Hickey, Michael

    2014-10-01

    Hallux valgus with an increased intermetatarsal angle is usually treated with a proximal metatarsal osteotomy. The proximal chevron osteotomy is commonly used but is technically difficult. This study compares the proximal opening wedge osteotomy of the first metatarsal with the proximal chevron osteotomy for the treatment of hallux valgus with an increased intermetatarsal angle. This prospective, randomized multicenter (three-center) study was based on the clinical outcome scores of the Short Form-36, the American Orthopaedic Foot & Ankle Society forefoot questionnaire, and the visual analog scale for pain, activity, and patient satisfaction. Subjects were assessed prior to surgery and at three, six, and twelve months postoperatively. Surgeon preference was evaluated based on questionnaires and the operative times required for each procedure. No significant differences were found for any of the patients' clinical outcome measurements between the two procedures. The proximal opening wedge osteotomy was found to lengthen, and the proximal chevron osteotomy was found to shorten, the first metatarsal. The intermetatarsal angles improved (decreased) significantly, from 14.8° ± 3.2° to 9.1° ± 2.9 (mean and standard deviation) after a proximal opening wedge osteotomy and from 14.6° ± 3.9° to 11.3° ± 4.0° after a proximal chevron osteotomy (p < 0.05 for both). Operative time required for performing a proximal opening wedge osteotomy is similar to that required for performing a proximal chevron osteotomy (mean and standard deviation, 67.1 ± 16.5 minutes compared with 69.9 ± 18.6 minutes; p = 0.510). Opening wedge and proximal chevron osteotomies have comparable radiographic outcomes and comparable clinical outcomes for pain, satisfaction, and function. The proximal opening wedge osteotomy lengthens, and the proximal chevron osteotomy shortens, the first metatarsal. The proximal opening wedge osteotomy was subjectively less technically demanding and was preferred by the orthopaedic surgeons in this study. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  10. Efficacy and tolerability of brinzolamide/brimonidine suspension and prostaglandin analogs in patients previously treated with dorzolamide/timolol solution and prostaglandin analogs.

    PubMed

    Lo, Jonathan S; Pang, Pierre M; Lo, Samuel C

    2016-01-01

    Fixed combination glaucoma medication is increasingly used in glaucoma treatment. There is a lack of comparative study in the literature of non-beta blocker combination agents used adjunctively with a glaucoma agent in a different class. The objective of this study is to evaluate the effect of intraocular pressure (IOP) control and tolerability of non-beta blocker combination suspension with prostaglandin analogs (PGA) in patients with open angle glaucoma who were previously treated with beta blocker combination solution with PGA. Open-label retrospective review of patient records. This study looked at patients with open angle glaucoma taking dorzolamide/timolol solution with PGA that were switched to brinzolamide/brimonidine combination suspension with PGA. This study reviewed the charts of all patients who were at least 21 years old with a clinical diagnosis of open-angle glaucoma or ocular hypertension in at least one eye. Patients needed to have been treated with concomitant use of PGA and dorzolamide/timolol solution for at least one month. Patients using dorzolamide/timolol solution plus PGA with medication related ocular irritation were switched to brinzolamide/brimonidine suspension with the same PGA. Best-corrected visual acuity, ocular hyperemia grading, slit lamp biomicroscopy and Goldmann applanation tonometry measurements, and patient medication preferences were assessed at baseline, 1 month and 3 months. Forty eyes with open angle glaucoma. The mean age of the patients was 68 and 60% were females. The IOP before the switch was 17.2 and 16.5 (P=0.70) following the switch at 3 months. We found a decreasing trend of ocular hyperemia (P=0.064) and strong preference (P=0.011) for non-beta blocker combination suspension but no difference of visual acuity and slit lamp findings. Brinzolamide/brimonidine combination suspension when used adjunctively with PGA is equally effective. Patients in this study reported greatly reduced ocular redness and shorter duration of stinging with non-beta blocker combination suspension. Their preference of it over dorzolamide/timolol combination solution makes it a viable treatment option, particularly for the aging glaucoma patient with comorbidities that restrict the beta blocker use.

  11. Tension Strength, Failure Prediction and Damage Mechanisms in 2D Triaxial Braided Composites with Notch

    NASA Technical Reports Server (NTRS)

    Norman, Timothy L.; Anglin, Colin

    1995-01-01

    The unnotched and notched (open hole) tensile strength and failure mechanisms of two-dimensional (2D) triaxial braided composites were examined. The effect of notch size and notch position were investigated. Damage initiation and propagation in notched and unnotched coupons were also examined. Theory developed to predict the normal stress distribution near an open hole and failure for tape laminated composites was evaluated for its applicability to 2D triaxial braided textile composite materials. Four different fiber architectures were considered; braid angle, yarn and braider size, percentage of longitudinal yarns and braider angle varied. Tape laminates equivalent to textile composites were also constructed for comparison. Unnotched tape equivalents were stronger than braided textiles but exhibited greater notch sensitivity. Notched textiles and tape equivalents have roughly the same strength at large notch sizes. Two common damage mechanisms were found: braider yarn cracking and near notch longitudinal yarn splitting. Cracking was found to initiate in braider yarns in unnotched and notched coupons, and propagate in the direction of the braider yarns until failure. Damage initiation stress decreased with increasing braid angle. No significant differences in prediction of near notch strain between textile and tape equivalents could be detected for small braid angle, but the correlations were weak for textiles with large braid angle. Notch strength could not be predicted using existing anisotropic theory for braided textiles due to their insensitivity to notch.

  12. Practical Tests with the "auto Control Slot." Part II : Discussion

    NASA Technical Reports Server (NTRS)

    Lachmann, G

    1930-01-01

    For some time the D.V.L. has been investigating the question of applicability of Handley Page slotted wings to German airplanes. Comparitive gliding tests were made with open and closed slots on an Albatros L 75 airplane equipped with the Handley Page "auto control slots." This investigation served to determine the effect of the auto control slot on the properties and performances of airplanes at large angles of attack. The most important problems were whether the angle of glide at small angles of attack can be increased by the adoption of the auto control slot and, in particular, as to whether the flight characteristics at large angles of attack are improved thereby and equilibrium in gliding flight is guaranteed even at larger than ordinary angles of attack.

  13. Practical Tests with the "auto Control Slot." Part I : Lecture

    NASA Technical Reports Server (NTRS)

    Lachmann, G

    1930-01-01

    For some time the D.V.L. has been investigating the question of applicability of Handley Page slotted wings to German airplanes. Comparitive gliding tests were made with open and closed slots on an Albatros L 75 airplane equipped with the Handley Page "auto control slots." This investigation served to determine the effect of the auto control slot on the properties and performances of airplanes at large angles of attack. The most important problems were whether the angle of glide at small angles of attack can be increased by the adoption of the auto control slot and, in particular, as to whether the flight characteristics at large angles of attack are improved thereby and equilibrium in gliding flight is guaranteed even at larger than ordinary angles of attack.

  14. Intramedullary nailing in opening wedge high tibial osteotomy-in vitro test for validation of a method of fixation.

    PubMed

    Burchard, Rene; Katerla, Denise; Hammer, Marina; Pahlkötter, Anke; Soost, Christian; Dietrich, Gerhard; Ohrndorf, Arne; Richter, Wolfgang; Lengsfeld, Markus; Christ, Hans-Jürgen; Graw, Jan Adriaan; Fritzen, Claus-Peter

    2018-02-01

    Opening wedge high tibial osteotomy (HTO) as a treatment in unicompartimental osteoarthritis of the knee can significantly relieve pain and prevent or at least delay an early joint replacement. The fixation of the osteotomy has undergone development and refinements during the last years. The angle-stable plate fixator is currently one of the most commonly used plates in HTOs. The angular stable fixation between screws and the plate offers a high primary stability to retain the correction with early weight-bearing protocols. This surgical technique is performed as a standard of care and generally well tolerated by the patients. Nevertheless, some studies observed that many patients complained about discomfort related to the implant. Therefore, the stability of two different intramedullary nails, a short implant used in humeral fractures and a long device used in tibial fractures for stabilization in valgus HTOs, was investigated as an alternative fixation technique. The plate fixator was defined as reference standard. Nine synthetic tibia models were standardly osteotomized and stabilized by one of the fixation devices. Axial compression was realized using a special testing machine and two protocols were performed: a multi-step fatigue test and a load-to-failure test. Overall motion, medial, and lateral displacements were documented. Fractures always occurred at the lateral cortex. Axial cyclic loading up to 800 N was tolerated by all implants without failure. The tibia nail provided highest fatigue strength under the load-to-failure conditions. The results suggest that intramedullary nailing might be used as an alternative concept in HTO.

  15. Open-loop GPS signal tracking at low elevation angles from a ground-based observation site

    NASA Astrophysics Data System (ADS)

    Beyerle, Georg; Zus, Florian

    2016-04-01

    For more than a decade space-based global navigation satellite system (GNSS) radio occultation (RO) observations are used by meteorological services world-wide for their numerical weather prediction models. In addition, climate studies increasingly rely on validated GNSS-RO data sets of atmospheric parameters. GNSS-RO profiles typically cover an altitude range from the boundary layer up to the upper stratosphere; their highest accuracy and precision, however, are attained at the tropopause level. In the lower troposphere, multipath ray propagation tend to induce signal amplitude and frequency fluctuations which lead to the development and implementation of open-loop signal tracking methods in GNSS-RO receiver firmwares. In open-loop mode the feed-back values for the carrier tracking loop are derived not from measured data, but from a Doppler frequency model which usually is extracted from an atmospheric climatology. In order to ensure that this receiver-internal parameter set, does not bias the carrier phase path observables, dual-channel open-loop GNSS-RO signal tracking was suggested. Following this proposal the ground-based "GLESER" (GPS low-elevation setting event recorder) campaign was established. Its objective was to disproof the existence of model-induced frequency biases using ground-based GPS observations at very low elevation angles. Between January and December 2014 about 2600 validated setting events, starting at geometric elevation angles of +2° and extending to -1°… - 1.5°, were recorded by the single frequency "OpenGPS" GPS receiver at a measurement site located close to Potsdam, Germany (52.3808°N, 13.0642°E). The study is based on the assumption that these ground-based observations may be used as proxies for space-based RO measurements, even if the latter occur on a one order of magnitude faster temporal scale. The "GLESER" data analysis shows that the open-loop Doppler model has negligible influence on the derived frequency profile provided signal-to-noise density ratios remain above about 30 dB Hz. At low signal levels, however, the dual-channel open-loop design, which tracks the same signal using two Doppler models separated by a 10 Hz offset, reveals a notable bias. A significant fraction of this bias is caused by frequency aliasing. The receiver's dual-channel setup, however, allows for unambiguous identification of the affected observation samples. Finally, the repeat patterns in terms of azimuth angle of the GPS orbit traces reveals characteristic signatures in both, signal amplitude and Doppler frequency with respect to the topography close to the observation site. On the other hand, mean vertical refractivity gradients extracted from ECMWF meteorological fields exhibit moderate correlations with observed signal amplitude fluctuations at negative elevation angles emphasizing the information content of low-elevation GPS signals with respect to the atmospheric state in the boundary layer.

  16. Early Ectopic Recurrence of Craniopharyngioma in the Cerebellopontine Angle.

    PubMed

    Mahdi, Mohamad-Motaz Al; Krauss, Joachim K; Nakamura, Makoto; Brandis, Almuth; Hong, Bujung

    2018-01-01

    Ectopic recurrence of craniopharyngioma in the cerebellopontine angle after surgical resection of a suprasellar craniopharyngioma is rare. Thus, only 5 cases were reported with a delay ranging between 4 and 26 years after removal of the primary tumor. We report a unique case of ectopic recurrence of craniopharyngioma in the cerebellopontine angle, which occurred at only 4 months after surgical resection of the primary tumor. A 24-year-old man underwent resection of a suprasellar craniopharyngioma via a right pterional approach four months earlier. During follow-up, cerebral magnetic resonance imaging (MRI) showed a round homogeneous contrast-enhancing tumor in the right cerebellopontine angle with neither relation to the internal auditory canal nor to the dura mater. After microsurgical resection, histopathological findings revealed ectopic recurrence of craniopharyngioma with similar tumors like the primary tumor. Although infrequent, craniopharyngioma may disseminate via the cerebrospinal fluid during surgical resection and grow in an ectopic place. Early follow-up and MRI scan following resection of a craniopharyngioma is recommended.

  17. Controlled five-year follow-up study of laser trabeculoplasty as primary therapy for open-angle glaucoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tuulonen, A.; Niva, A.K.; Alanko, H.I.

    1987-10-15

    We followed up 32 eyes of 32 patients with early glaucoma (22 with capsular glaucoma and ten with simple glaucoma) who received laser trabeculoplasty as a primary therapy. These eyes were compared with a matched control group of 32 eyes treated with medication initially. The success rate (intraocular pressure below 22 mm Hg with laser alone or medication alone) at five years was 50% (16 of 32 eyes) in the laser-treated group and 22% (seven of 32 eyes) in the control group (P less than .02). The control group required more modifications of their therapy to control intraocular pressure. Themore » neuroretinal rim area in the control eyes decreased 2.5 times as much as in the laser group (P = .017). Changes in the Friedmann visual fields did not differ significantly between the two groups.« less

  18. Brain morphometry in blind and sighted subjects.

    PubMed

    Maller, Jerome J; Thomson, Richard H; Ng, Amanda; Mann, Collette; Eager, Michael; Ackland, Helen; Fitzgerald, Paul B; Egan, Gary; Rosenfeld, Jeffrey V

    2016-11-01

    Previous neuroimaging studies have demonstrated structural brain alterations in blind subjects, but most have focused on primary open angle glaucoma or retinopathy of prematurity, used low-field scanners, a limited number of receive channels, or have presented uncorrected results. We recruited 10 blind and 10 age and sex-matched controls to undergo high-resolution MRI using a 3T scanner and a 32-channel receive coil. We evaluated whole-brain morphological differences between the groups as well as manual segmentation of regional hippocampal volumes. There were no hippocampal volume differences between the groups. Whole-brain morphometry showed white matter volume differences between blind and sighted groups including localised larger regions in the visual cortex (occipital gyral volume and thickness) among those with blindness early in life compared to those with blindness later in life. Hence, in our patients, blindness resulted in brain volumetric differences that depend upon duration of blindness. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Himalayan Mtns. and Mt. Everest Earth observation taken by Dan Bursch during EXP. Four

    NASA Image and Video Library

    2002-03-20

    ISS004-E-8852 (20 March 2002) --- Astronaut Daniel W. Bursch, flight engineer for Expedition Four aboard the International Space Station, used a digital still camera to capture this image of Mt. Everest in the Himalayan Range. The mountain is near frame center. Here are the notes Bursch added in one of his reports to ground controllers: "One morning I happened to be up early. I glanced at our world map and saw that we’d be passing near Mt Everest soon. I checked the computer, realized that we were in an attitude that would allow me to open the window shutter and there was Mt Everest! It almost seemed to jump out at me. The low sun angle (it was close to orbital sunrise) gave tremendous relief to the mountains. It was just one of those sights that will be forever burned into my brain!"

  20. Open conformation of a substrate-binding cleft: sup 19 F NMR studies of cleft angle in the D-galactose chemosensory receptor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luck, L.A.; Falke, J.J.

    1991-07-02

    The Escherichia coli D-galactose and D-glucose receptor is a two-domain structure with a sugar-binding site at the interface between domains. The structure of the closed cleft containing bound D-glucose has been determined crystalloghraphically, but the open cleft remains to be characterized. The present study illustrates a generalizable approach that is used to detect and analyze both the open- and closed-cleft conformations in solution. A {sup 19}F nucleus located inside the cleft is monitored by {sup 19}F NMR. When the cleft is occupied by D-glucose, the {sup 19}F nucleus is found to be inaccessible to the aqueous paramagnetic probe Gd{center dot}EDTA,more » verifying that the occupied cleft is closed in solution and inaccessible to bulk solvent. When the cleft is empty, the {sup 19}F nucleus becomes accessible to the paramagnet such that the distance of closest approach is r {le} 10 {angstrom}, indicating that the empty cleft opens at least transiently by an angle {theta} {ge} 18 {plus minus} 3{degrees}.« less

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mizuta, Akira; Ioka, Kunihito

    We investigate the jet propagation and breakout from the stellar progenitor for gamma-ray burst (GRB) collapsars by performing two-dimensional relativistic hydrodynamic simulations and analytical modeling. We find that the jet opening angle is given by θ{sub j} ∼ 1/5Γ{sub 0} and infer the initial Lorentz factor of the jet at the central engine, Γ{sub 0}, is a few for existing observations of θ{sub j}. The jet keeps the Lorentz factor low inside the star by converging cylindrically via collimation shocks under the cocoon pressure and accelerates at jet breakout before the free expansion to a hollow-cone structure. In this newmore » picture, the GRB duration is determined by the sound crossing time of the cocoon, after which the opening angle widens, reducing the apparent luminosity. Some bursts violating the maximum opening angle θ{sub j,{sub max}} ∼ 1/5 ∼ 12° imply the existence of a baryon-rich sheath or a long-acting jet. We can explain the slopes in both Amati and Yonetoku spectral relations using an off-centered photosphere model, if we make only one assumption that the total jet luminosity is proportional to the initial Lorentz factor of the jet. We also numerically calibrate the pre-breakout model (Bromberg et al.) for later use.« less

  2. Examining Delay Intervals in the Diagnosis and Treatment of Primary Open Angle Glaucoma in an Egyptian Population and Its Impact on Lifestyle

    PubMed Central

    Abu Hussein, Nahla B.; Habib, Ahmed E.; El Sayed, Yasmine M.

    2016-01-01

    Purpose. To examine causes as well as extent of delay in diagnosis and treatment of primary open angle glaucoma patients in a sample of Egyptians. Patients and Methods. 440 patients with primary open angle glaucoma were interviewed to evaluate delay in their diagnosis and treatment. The extent and cause of delay were investigated. The total delay interval, if any, was correlated with socioeconomic and other factors. Results. The median total delay was one year, with 50% of patients having a total delay of 1 year or less, of which 25% exhibited zero total delay. 25% of patients had a delay ranging from 1 to 3 years, and 25% had a total delay ranging from 3 to 27 years. Diagnostic delay accounted for 43.03% of cases. Longer delays were met in patients with certain socioeconomic factors. Patients with a positive family history of glaucoma displayed shorter delay periods. Conclusion. Significant delay in the diagnosis and treatment of glaucoma was found. Poor socioeconomic status seems to hinder timely diagnosis and treatment of POAG. Certain socioeconomic factors seem to correlate with the extent of delay. More effort is thus needed to subsidize the cost of investigations and treatment for glaucoma patients. PMID:28116140

  3. Modifiable factors in the management of glaucoma: a systematic review of current evidence.

    PubMed

    Hecht, Idan; Achiron, Asaf; Man, Vitaly; Burgansky-Eliash, Zvia

    2017-04-01

    Primary open angle glaucoma is a chronic optic neuropathy affecting millions of people worldwide and represents a major public health issue. Environmental factors, behaviors, and diet are intimately related to patient health and may play a role in the pathogenesis and progression of glaucoma. This study aims to review the literature, focusing on the last three years, regarding modifiable lifestyle interventions in the management of primary open angle glaucoma. Electronic databases were searched for studies published between January 2013 and July 2016 on the topic of lifestyle interventions in primary open angle glaucoma. Sleeping with the head elevated and avoiding the worst eye-dependent side during sleep may slightly lower intraocular pressure and reduce visual field loss. Some food supplements and moderate aerobic exercise may also reduce intraocular pressure up to 2.0 and 3.0 mmHg, respectively. Frequency of coffee intake may be associated with disease progression. Potential negative effects are associated with weight-lifting and yoga exercises. Certain lifestyle habits could influence glaucoma progression, yet no specific interventions are currently supported by robust evidence. Awareness of the possible influences of certain habits should help guide clinical advice and is important to help patients avoid adverse outcomes and take an active role in the management of their disease.

  4. First-line treatment for elevated intraocular pressure (IOP) associated with open-angle glaucoma or ocular hypertension: focus on bimatoprost

    PubMed Central

    Law, Simon K

    2007-01-01

    The goal of treatment for open-angle glaucoma or ocular hypertension is to improve quality of life through reduction of intraocular pressure (IOP) to preserve visual function. Prostaglandins, as a newer class of ocular hypotensive agents, have been shown to be effective in IOP reduction by the primary mechanism of action of increase the uveoscleral outflow. Bimatoprost is a member this class, but different from the other members by having an ethyl amide group rather than an isopropyl ester at the C-1 carbon of the alpha chain. Bimatoprost used once daily has been shown to be more effect in IOP reduction than other classes of topical ocular hypotensive agents including beta-blockers, carbonic anhydrase inhibitors, and alpha agonists. Comparing with other topical prostaglandins, bimatoprost may be slightly more effective in IOP reduction, but the clinical significance is uncertain. The commonly reported adverse events associated with bimatoprost are localized to the eye and include conjunctival hyperemia, changes in the pigmentation of the periocular skin and iris, and eyelash darkening and growth. It is currently approved by the Food and Drug Administration (FDA) and the European Commission (EC) for first-line therapy for the reduction of elevated IOP in patients with open-angle glaucoma or ocular hypertension. PMID:19668476

  5. Spatial hearing in Cope’s gray treefrog: I. Open and closed loop experiments on sound localization in the presence and absence of noise

    PubMed Central

    Caldwell, Michael S.; Bee, Mark A.

    2014-01-01

    The ability to reliably locate sound sources is critical to anurans, which navigate acoustically complex breeding choruses when choosing mates. Yet, the factors influencing sound localization performance in frogs remain largely unexplored. We applied two complementary methodologies, open and closed loop playback trials, to identify influences on localization abilities in Cope’s gray treefrog, Hyla chrysoscelis. We examined localization acuity and phonotaxis behavior of females in response to advertisement calls presented from 12 azimuthal angles, at two signal levels, in the presence and absence of noise, and at two noise levels. Orientation responses were consistent with precise localization of sound sources, rather than binary discrimination between sources on either side of the body (lateralization). Frogs were unable to discriminate between sounds arriving from forward and rearward directions, and accurate localization was limited to forward sound presentation angles. Within this region, sound presentation angle had little effect on localization acuity. The presence of noise and low signal-to-noise ratios also did not strongly impair localization ability in open loop trials, but females exhibited reduced phonotaxis performance consistent with impaired localization during closed loop trials. We discuss these results in light of previous work on spatial hearing in anurans. PMID:24504182

  6. Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: an in vitro study.

    PubMed

    Ebrahimi, N; Claus, B; Lee, C-Y; Biondi, A; Benndorf, G

    2007-05-01

    Radiographic visibility of self-expandable intracranial stents is insufficient for assessment of conformability and deployment characteristics. The purpose of this study was to evaluate stent mechanics in a curved vessel model by using Flat-Panel CT (FPCT). The following stents were used: Neuroform 2, Neuroform Treo, Enterprise, and LEO. All stents were bent in the same polytetrafluoroethylene tubes with various angles ranging from 150 degrees to 30 degrees . To visualize potential prolapse of the stent struts, 4-, 5-, and 8-mm openings were created. FPCTs were obtained using a C-arm with flat detector. FPCT scans provided excellent visualization of deployment characteristics and stent mechanics and was superior to digital subtraction angiography (DSA) and digital radiography (DR). The Neuroform2/Treo showed, with increasing angle and diameter of the opening, a continuous increase in cell size. These stents also showed an outward prolapse at the convexity and an inwards prolapse of struts at the concavity of the curvature. The Enterprise showed an increasing trend to flatten and to kink with curvatures that are more acute. The LEO showed fewer trends to kink but an inward crimping of its ends with more acute angles. Deployment characteristics and conformability to a curved vessel model vary considerably, depending on the angle and the stent design. Adverse mechanics such as increased cell opening, strut prolapse, flattening, and kinking occur during stent placement in a curved vessel model, and may gain clinical importance. FPCT is superior to DSA and DR in visualizing small metallic stents and enables accurate detection of adverse stent mechanics.

  7. Review of pre-rift continental fits and plate kinematic models for the Gulf of Mexico opening

    NASA Astrophysics Data System (ADS)

    Steier, A.; Mann, P.

    2016-12-01

    We review models for the opening of the Gulf of Mexico (GOM) by: 1) subdividing them into historical groupings; 2) demonstrating their strengths and weaknesses using GPlates; and 3) illustrating the compatibility of models for GOM opening with the surrounding plate mosaic in the Central Atlantic and Caribbean. Tectonic models for GOM opening during the 1970's and 1980's disagreed on whether the Yucatan continental block originated inside or outside the GOM, but difficulties in filling the continental underlap in reconstructions of pre-rift Pangea eventually led to a consensus that the Yucatan block originated inside the GOM. The 1980's saw the advent of the "piggyback model" for GOM evolution based on the assumption that the Jurassic opening of the GOM formed a southwestward extension of the Central Atlantic spreading system and opened about its same pole of rotation. This single-phase model eventually fell out of favor as refraction surveys determined that the existence of a wedge-shaped area of oceanic crust in the deep GOM (widening from east to west) was not compatible with the single, NW-SE opening direction proposed by the piggyback model. The early 2000's saw the appearance of a two-phase opening model as a solution to the existence of a broad zone of NW-SE continental extension in the northern GOM that was succeeded by a more NS-directed phase of extension that in some areas cut at right angles across structures produced during the first rift phase. The second phase of late Jurassic rifting and oceanic crust formation is the outcome of counterclockwise rotation of the Yucatan block that is thought to have been caused by forces acting on the edges of the block. By the earliest Cretaceous rifting in the GOM has ended although tectonic events in Mexico and the northern Caribbean reactivate and influence GOM sedimentation. We provide a GPlates restoration from Triassic to Recent that takes into account all available geologic and geophysical data and illustrates the two-phase GOM opening model which appears to be the tectonic model that can explain the most geologic and geophysical datasets from the Caribbean.

  8. [Predicting the probability of development and progression of primary open angle glaucoma by regression modeling].

    PubMed

    Likhvantseva, V G; Sokolov, V A; Levanova, O N; Kovelenova, I V

    2018-01-01

    Prediction of the clinical course of primary open-angle glaucoma (POAG) is one of the main directions in solving the problem of vision loss prevention and stabilization of the pathological process. Simple statistical methods of correlation analysis show the extent of each risk factor's impact, but do not indicate the total impact of these factors in personalized combinations. The relationships between the risk factors is subject to correlation and regression analysis. The regression equation represents the dependence of the mathematical expectation of the resulting sign on the combination of factor signs. To develop a technique for predicting the probability of development and progression of primary open-angle glaucoma based on a personalized combination of risk factors by linear multivariate regression analysis. The study included 66 patients (23 female and 43 male; 132 eyes) with newly diagnosed primary open-angle glaucoma. The control group consisted of 14 patients (8 male and 6 female). Standard ophthalmic examination was supplemented with biochemical study of lacrimal fluid. Concentration of matrix metalloproteinase MMP-2 and MMP-9 in tear fluid in both eyes was determined using 'sandwich' enzyme-linked immunosorbent assay (ELISA) method. The study resulted in the development of regression equations and step-by-step multivariate logistic models that can help calculate the risk of development and progression of POAG. Those models are based on expert evaluation of clinical and instrumental indicators of hydrodynamic disturbances (coefficient of outflow ease - C, volume of intraocular fluid secretion - F, fluctuation of intraocular pressure), as well as personalized morphometric parameters of the retina (central retinal thickness in the macular area) and concentration of MMP-2 and MMP-9 in the tear film. The newly developed regression equations are highly informative and can be a reliable tool for studying of the influence vector and assessment of pathogenic potential of the independent risk factors in specific personalized combinations.

  9. Analysis of Balance Ability Dependent on the Angle of the Knee Joint in Females in Their 20s

    PubMed Central

    Yoon, Se-Won; Lee, Jeong-Woo; Cho, Woon-Su; Kim, An-Na; Lee, Kyung-Hee

    2013-01-01

    The aim of this study was to investigate how balance ability according to angle of the knee joint changes in young female adults wearing a knee orthosis. [Methods] This study was conducted with 11 healthy female adults. The subjects used a knee brace that could be set to angles of 0°, 15°, and 30° of knee flexion. The ability to balance was evaluated by balance assessment. A total of four postures were used for measurements: a forward-facing posture with the eyes open on a stable surface (NO), a forward-facing posture with the eyes closed on a stable surface (NC), a forward-facing posture with the eyes open on an unstable surface (PO), and a forward-facing posture with the eyes closed on an unstable surface (PC). [Results] Regarding the weight distribution index and stability index on a stable surface, there was no interaction according to whether there was visual deprivation or not or according to knee flexion angle. Furthermore, the stability index on an unstable surface showed no interaction according to whether there was visual deprivation or not or according to knee flexion angle. But the WDI on a stable surface showed no interaction according to whether there was visual deprivation or not or according to knee flexion angle. [Conclusion] There were significant differences in the knee extension range of motion of normal elderly people and knee osteoarthritis, and the quadriceps femoris played an important role in knee function in individuals with knee osteoarthritis. PMID:24259902

  10. Simulations of Gamma-Ray Burst Jets in a Stratified External Medium: Dynamics, Afterglow Light Curves, Jet Breaks, and Radio Calorimetry

    NASA Astrophysics Data System (ADS)

    De Colle, Fabio; Ramirez-Ruiz, Enrico; Granot, Jonathan; Lopez-Camara, Diego

    2012-05-01

    The dynamics of gamma-ray burst (GRB) jets during the afterglow phase is most reliably and accurately modeled using hydrodynamic simulations. All published simulations so far, however, have considered only a uniform external medium, while a stratified external medium is expected around long duration GRB progenitors. Here, we present simulations of the dynamics of GRB jets and the resulting afterglow emission for both uniform and stratified external media with ρextvpropr -k for k = 0, 1, 2. The simulations are performed in two dimensions using the special relativistic version of the Mezcal code. Common to all calculations is the initiation of the GRB jet as a conical wedge of half-opening angle θ0 = 0.2 whose radial profile is taken from the self-similar Blandford-McKee solution. The dynamics for stratified external media (k = 1, 2) are broadly similar to those derived for expansion into a uniform external medium (k = 0). The jet half-opening angle is observed to start increasing logarithmically with time (or radius) once the Lorentz factor Γ drops below θ-1 0. For larger k values, however, the lateral expansion is faster at early times (when Γ > θ-1 0) and slower at late times with the jet expansion becoming Newtonian and slowly approaching spherical symmetry over progressively longer timescales. We find that, contrary to analytic expectations, there is a reasonably sharp jet break in the light curve for k = 2 (a wind-like external medium), although the shape of the break is affected more by the viewing angle (for θobs <= θ0) than by the slope of the external density profile (for 0 <= k <= 2). Steeper density profiles (i.e., increasing k values) are found to produce more gradual jet breaks while larger viewing angles cause smoother and later appearing jet breaks. The counterjet becomes visible as it becomes sub-relativistic, and for k = 0 this results in a clear bump-like feature in the light curve. However, for larger k values the jet decelerates more gradually, causing only a mild flattening in the radio light curve that might be hard to discern when k = 2. Late-time radio calorimetry, which makes use of a spherical flow approximation near the non-relativistic transition, is likely to consistently overestimate the true energy by up to a factor of a few for k = 2, but likely to either overpredict or underpredict it by a smaller factor for k = 0, 1.

  11. Evaluation of anterior chamber angle under dark and light conditions in angle closure glaucoma: An anterior segment OCT study.

    PubMed

    Masoodi, Habibeh; Jafarzadehpur, Ebrahim; Esmaeili, Alireza; Abolbashari, Fereshteh; Ahmadi Hosseini, Seyed Mahdi

    2014-08-01

    To evaluate changes of nasal and temporal anterior chamber angle (ACA) in subjects with angle closure glaucoma using Spectralis AS-OCT (SAS-OCT) under dark and light conditions. Based on dark-room gonioscopy, 24 subjects with open angles and 86 with narrow angles participated in this study. The nasal and temporal angle opening distance at 500 μm anterior to the scleral spur (AOD500), nasal and temporal ACA were measured using SAS-OCT in light and dark conditions. In 2 groups, ACA and AOD500 in nasal and temporal quadrants were significantly greater in light compared to dark (all with p=0.000). The AOD500 and ACA were significantly higher in nasal than temporal in measured conditions for 2 groups except the ACA and AOD500 of normal group measured in light. The difference between nasal and temporal in dark (29.07 ± 65.71 μm for AOD500 and 5.7 ± 4.07° for ACA) was greater than light (24.86 ± 79.85 μm for AOD500 and 2.09 ± 7.21° for ACA) condition. But the difference was only significant for ACA (p=0.000). The correlation analysis showed a negative correlation between AOD500 and pupil diameter in temporal and nasal quadrants (both with p=0.000). While temporal AOD500 difference correlated with spherical equivalent, temporal and asal gonioscopy, nasal AOD correlated with IOP, temporal and nasal gonioscopy. Clinically important changes in ACA structure could be detected with SAS-OCT in nasal and temporal quadrants under different illumination intensity. The results could help in improvement of examination condition for better and more accurate assessment of individuals with angle closure glaucoma. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  12. MO-F-CAMPUS-T-01: Radiosurgery of Multiple Brain Metastases with Single-Isocenter VMAT: Optimizing Treatment Geometry to Reduce Normal Brain Dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Q; Snyder, K; Liu, C

    Purpose: To develop an optimization algorithm to reduce normal brain dose by optimizing couch and collimator angles for single isocenter multiple targets treatment of stereotactic radiosurgery. Methods: Three metastatic brain lesions were retrospectively planned using single-isocenter volumetric modulated arc therapy (VMAT). Three matrices were developed to calculate the projection of each lesion on Beam’s Eye View (BEV) by the rotating couch, collimator and gantry respectively. The island blocking problem was addressed by computing the total area of open space between any two lesions with shared MLC leaf pairs. The couch and collimator angles resulting in the smallest open areas weremore » the optimized angles for each treatment arc. Two treatment plans with and without couch and collimator angle optimization were developed using the same objective functions and to achieve 99% of each target volume receiving full prescription dose of 18Gy. Plan quality was evaluated by calculating each target’s Conformity Index (CI), Gradient Index (GI), and Homogeneity index (HI), and absolute volume of normal brain V8Gy, V10Gy, V12Gy, and V14Gy. Results: Using the new couch/collimator optimization strategy, dose to normal brain tissue was reduced substantially. V8, V10, V12, and V14 decreased by 2.3%, 3.6%, 3.5%, and 6%, respectively. There were no significant differences in the conformity index, gradient index, and homogeneity index between two treatment plans with and without the new optimization algorithm. Conclusion: We have developed a solution to the island blocking problem in delivering radiation to multiple brain metastases with shared isocenter. Significant reduction in dose to normal brain was achieved by using optimal couch and collimator angles that minimize total area of open space between any of the two lesions with shared MLC leaf pairs. This technique has been integrated into Eclipse treatment system using scripting API.« less

  13. The influence of third molars in the line of mandibular angle fractures on wound and bone healing.

    PubMed

    Ulbrich, N; Ettl, T; Waiss, W; Gosau, M; Moralis, A; Reichert, T E; Mueller, S

    2016-07-01

    The objective of this study was to evaluate postoperative complications after removal or retention of the third molar in the line of mandibular angle fractures. This retrospective study included the data of 98 patients with a molar in the line of a mandibular angle fracture treated with internal reduction and mini-plate fixation at our department over 9 years. Patients were classified into two groups: tooth removal during osteosynthesis (n = 45) and tooth retention (n = 55). The primary target criterion was the incidence of minor (outpatient treatment, local measures) and major (surgical revision, rehospitalisation) complications. Time between trauma and surgery was 1.4 days (range 0 to 12), and the average follow-up 291 days (range 66 to 863). Regarding the eruption status, 26 of 52 (50.0 %) impacted third molars, 11 of 19 (57.9 %) incompletely erupted and 8 of 27 (29.6 %) completely erupted molars had been removed during open reduction. Overall, 17 (17.3 %) patients had postoperative minor (n = 7) or major (n = 10) complications, in detail 10/45 (22.0 %) patients after tooth removal and 7/55 (13 %) patients after tooth retention (p = 0.286). Complication rates between impacted and incompletely erupted third molars (impacted molars 15.0 %, incompletely erupted molars 10.0 %) did not differ significantly, but completely erupted molars had a complication rate of 26.0 %. Mandibular angle fractures with a completely erupted third molar show the highest complication rate after open reduction and osteosynthesis. Retention of a non-infectious third molar facilitates open reduction and does not increase the complication risk. The study helps with the decision of removing or retention of a third molar during surgical treatment of a mandibular angle fracture.

  14. Evaluation and comparison of indentation ultrasound biomicroscopy gonioscopy in relative pupillary block, peripheral anterior synechia, and plateau iris configuration.

    PubMed

    Matsunaga, Koichi; Ito, Kunio; Esaki, Koji; Sugimoto, Kota; Sano, Toru; Miura, Katsuya; Sasoh, Mikio; Uji, Yukitaka

    2004-12-01

    To evaluate and compare the findings and changes of the anterior chamber angle configuration with indentation ultrasound biomicroscopy (UBM) gonioscopy in relative pupillary block (RPB), peripheral anterior synechia (PAS), and plateau iris configuration (PIC). This study included 73 eyes of 52 patients with RPB (n = 26), PAS (n = 21), or PIC (n = 26). First, a conventional UBM scan was performed using a normal size standard eye cup before indentation. Then, for indentation UBM gonioscopy, scans were performed using a new eye cup that we designed. For evaluation of the angle, angle opening distance 500 and angle recess area were recorded and evaluated with regard to the effect of expansion on the anterior chamber angle. Indentation UBM gonioscopy showed the characteristic images in each of the eyes. The angle of all examined eyes was significantly widened with indentation (P < 0.01). The angle changes in eyes with RPB were significantly greater than in eyes with PAS or PIC (P < 0.01). Indentation UBM gonioscopy is a very useful method for observing the angle and diagnosis of RPB, PAS, and PIC.

  15. The onset of visual experience gates auditory cortex critical periods

    PubMed Central

    Mowery, Todd M.; Kotak, Vibhakar C.; Sanes, Dan H.

    2016-01-01

    Sensory systems influence one another during development and deprivation can lead to cross-modal plasticity. As auditory function begins before vision, we investigate the effect of manipulating visual experience during auditory cortex critical periods (CPs) by assessing the influence of early, normal and delayed eyelid opening on hearing loss-induced changes to membrane and inhibitory synaptic properties. Early eyelid opening closes the auditory cortex CPs precociously and dark rearing prevents this effect. In contrast, delayed eyelid opening extends the auditory cortex CPs by several additional days. The CP for recovery from hearing loss is also closed prematurely by early eyelid opening and extended by delayed eyelid opening. Furthermore, when coupled with transient hearing loss that animals normally fully recover from, very early visual experience leads to inhibitory deficits that persist into adulthood. Finally, we demonstrate a functional projection from the visual to auditory cortex that could mediate these effects. PMID:26786281

  16. Hazards in Motion: Development of Mobile Geofences for Use in Logging Safety

    PubMed Central

    Zimbelman, Eloise G.; Keefe, Robert F.; Strand, Eva K.; Kolden, Crystal A.; Wempe, Ann M.

    2017-01-01

    Logging is one of the most hazardous occupations in the United States. Real-time positioning that uses global navigation satellite system (GNSS) technology paired with radio frequency transmission (GNSS-RF) has the potential to reduce fatal and non-fatal accidents on logging operations through the use of geofences that define safe work areas. Until recently, most geofences have been static boundaries. The aim of this study was to evaluate factors affecting mobile geofence accuracy in order to determine whether virtual safety zones around moving ground workers or equipment are a viable option for improving situational awareness on active timber sales. We evaluated the effects of walking pace, transmission interval, geofence radius, and intersection angle on geofence alert delay using a replicated field experiment. Simulation was then used to validate field results and calculate the proportion of GNSS error bearings resulting in early alerts. The interaction of geofence radius and intersection angle affected safety geofence alert delay in the field experiment. The most inaccurate alerts were negative, representing early warning. The magnitude of this effect was largest at the greatest intersection angles. Simulation analysis supported these field results and also showed that larger GNSS error corresponded to greater variability in alert delay. Increasing intersection angle resulted in a larger proportion of directional GNSS error that triggered incorrect, early warnings. Because the accuracy of geofence alerts varied greatly depending on GNSS error and angle of approach, geofencing for occupational safety is most appropriate for general situational awareness unless real-time correction methods to improve accuracy or higher quality GNSS-RF transponders are used. PMID:28394303

  17. Prospective Study of Oral Health and Risk of Primary Open-Angle Glaucoma in Men: Data from the Health Professionals Follow-up Study.

    PubMed

    Pasquale, Louis R; Hyman, Leslie; Wiggs, Janey L; Rosner, Bernard A; Joshipura, Kaumudi; McEvoy, Mark; McPherson, Zachary E; Danias, John; Kang, Jae H

    2016-11-01

    Tooth loss or periodontal disease is associated with systemic endothelial dysfunction, which has been implicated in primary open-angle glaucoma (POAG). The relationship between oral health and POAG has received limited attention. Thus, we evaluated the association between oral health history and risk of POAG and POAG subtypes. Prospective cohort study. Health Professionals Follow-up Study participants (40 536 men) followed biennially from 1986 to 2012. At each 2-year risk period, eligible participants were aged 40+ years, were free of POAG, and reported eye examinations. By using validated questions, we updated participants' status on number of natural teeth, teeth lost, periodontal disease with bone loss, and root canal treatments. During follow-up, 485 incident cases of POAG were confirmed with medical records and classified into subtypes defined by intraocular pressure (IOP; ≥ or <22 mmHg) or visual field (VF) loss pattern at diagnosis (peripheral loss only or early paracentral loss). Multivariable relative risks (MVRRs) and 95% confidence intervals (CIs) were estimated. Number of natural teeth, periodontal disease, and root canal treatment were not associated with POAG. However, compared with no report of tooth loss, a report of losing teeth within the past 2 years was associated with a 1.45-fold increased risk of POAG (95% CI, 1.06-1.97); in particular, a report within the past 2 years of both losing teeth and having a prevalent diagnosis of periodontal disease was associated with a 1.85-fold increased risk of POAG (95% CI, 1.07-3.18). The associations with recent tooth loss were not significantly different for the POAG subtypes (P for heterogeneity ≥0.36), although associations were strongest in relation to the POAG subtypes with IOP <22 mmHg (MVRR, 1.93; 95% CI, 1.09-3.43) and early paracentral VF loss (MVRR, 2.27; 95% CI, 1.32-3.88). Although the number of natural teeth was not associated with risk of POAG, recent tooth loss was associated with an increased risk of POAG. Because these findings may be due to chance, they need confirmation in larger studies. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  18. Influence of guide vane opening on the flow phenomena in a pump turbine during a fast transition from pump mode to generating mode

    NASA Astrophysics Data System (ADS)

    Stens, C.; Riedelbauch, S.

    2017-04-01

    Due to a more fluctuating energy production caused by renewable energies such as wind and solar power, the number of changes between operating points in pumped storage power plants has increased over the last years. To further increase available regulating power, it is desirable to speed up these changes of operation conditions in Hydro units. Previous studies showed that CFD is well capable of predicting the flow phenomena in the machine under unsteady conditions for a large guide vane opening angle. The present paper investigates the benefits of nearly closed guide vanes during the transition. Results are compared between the two different angles as well as between simulation and measurement.

  19. Nonimaging Optical Illumination System

    DOEpatents

    Winston, Roland

    1994-02-22

    A nonimaging illumination or concentration optical device. An optical device is provided having a light source, a light reflecting surface with an opening and positioned partially around the light source which is opposite the opening of the light reflecting surface. The light reflecting surface is disposed to produce a substantially uniform intensity output with the reflecting surface defined in terms of a radius vector R.sub.i in conjunction with an angle .phi..sub.i between R.sub.i, a direction from the source and an angle .theta..sub.i between direct forward illumination and the light ray reflected once from the reflecting surface. R.sub.i varies as the exponential of tan (.phi..sub.i -.theta..sub.i)/2 integrated over .phi..sub.i.

  20. Low-angle faulting in strike-slip dominated settings: Seismic evidence from the Maritimes Basin, Canada

    NASA Astrophysics Data System (ADS)

    Pinet, Nicolas; Dietrich, Jim; Duchesne, Mathieu J.; Hinds, Steve J.; Brake, Virginia

    2018-07-01

    The Maritimes Basin is an upper Paleozoic sedimentary basin centered in the Gulf of St. Lawrence (Canada). Early phases of basin formation included the development of partly connected sub-basins bounded by high-angle faults, in an overall strike-slip setting. Interpretation of reprocessed seismic reflection data indicates that a low-angle detachment contributed to the formation of a highly asymmetric sub-basin. This detachment was rotated toward a lower angle and succeeded by high-angle faults that sole into the detachment or cut it. This model bears similarities to other highly extended terranes and appears to be applicable to strike-slip and/or transtensional settings.

  1. Effectiveness Using Circular Fibre Steel Flap Gate As a Control Structure Towards the Hydraulic Characteristics in Open Channel

    NASA Astrophysics Data System (ADS)

    Adib, M. R. M.; Amirza, A. R. M.; Wardah, T.; Junaidah, A.

    2016-07-01

    Hydraulic control gate structure plays an important role in regulating the flow of water in river, canal or water reservoir. One of the most appropriate structures in term of resolving the problem of flood occured is the construction of circular fibre steel flap gate. Therefore, an experiment has been conducted by using an open channel model at laboratory. In this case, hydraulic jump and backwater were the method to determined the hydraulic characteristics of circular fibre steel flap gate in an open channel model. From the experiment, the opening angle of flap gate can receive discharges with the highest flow rate of 0.035 m3/s with opening angle was 47°. The type of jump that occurs at the slope of 1/200 for a distance of 5.0 m is a standing jump or undulating wave. The height of the backwater can be identified based on the differences of specific force which is specific force before jump, F1 and specific force after jump, F2 from the formation of backwater. Based on the research conducted, the tendency of incident backwater wave occurred was high in every distance of water control location from water inlet is flap slope and the slope of 1/300 which is 0.84 m/s and 0.75 m/s of celerity in open channel model.

  2. Retrospective 25-year follow-up of treatment outcomes in angle Class III patients : Early versus late treatment.

    PubMed

    Wendl, B; Muchitsch, A P; Winsauer, H; Walter, A; Droschl, H; Jakse, N; Wendl, M; Wendl, T

    2017-05-01

    To assess early versus late treatment of Class III syndrome for skeletal and dental differences. Thirty-eight Class III patients treated with a chincup were retrospectively analyzed. Baseline data were obtained by reviewing pretreatment (T0) anamnestic records, cephalograms, and casts. The cases were assigned to an early or a late treatment group based on age at T0 (up to 9 years or older than 9 years but before the pubertal growth spurt). Both groups were further compared based on posttreatment data (T1) and long-term follow-up data collected approximately 25 years after treatment (T2). Early treatment was successful in 74% and late treatment in 67% of cases. More failures were noted among male patients. The late treatment group was characterized post therapeutically by significantly more pronounced skeletal parameters of jaw size relative to normal Class I values; in addition, a greater skeletal discrepancy between maxilla and mandible, higher values for mandibular length, Cond-Pog, ramus height, overjet, anterior posterior dysplasia indicator (APDI), lower anterior face height, and gonial angle were measured at T1. The angle between the AB line and mandibular plane was found to be larger at T0, T1, and T2, as well as more pronounced camouflage positions of the lower anterior teeth at T0. The early treatment group was found to exhibit greater amounts of negative overjet at T0 but more effective correction at T1. Early treatment of Class III syndrome resulted in greater skeletal changes with less dental compensation.

  3. Effects of wind velocity and slope on flame properties

    Treesearch

    David R. Weise; Gregory S. Biging

    1996-01-01

    Abstract: The combined effects of wind velocity and percent slope on flame length and angle were measured in an open-topped, tilting wind tunnel by burning fuel beds composed of vertical birch sticks and aspen excelsior. Mean flame length ranged from 0.08 to 1.69 m; 0.25 m was the maximum observed flame length for most backing fires. Flame angle ranged from -46o to 50o...

  4. CONTINUOUS ROTATION SCATTERING CHAMBER

    DOEpatents

    Verba, J.W.; Hawrylak, R.A.

    1963-08-01

    An evacuated scattering chamber for use in observing nuclear reaction products produced therein over a wide range of scattering angles from an incoming horizontal beam that bombards a target in the chamber is described. A helically moving member that couples the chamber to a detector permits a rapid and broad change of observation angles without breaching the vacuum in the chamber. Also, small inlet and outlet openings are provided whose size remains substantially constant. (auth)

  5. Signature of non-isotropic distribution of stellar rotation inclination angles in the Praesepe cluster

    NASA Astrophysics Data System (ADS)

    Kovacs, Geza

    2018-04-01

    The distribution of the stellar rotation axes of 113 main sequence stars in the open cluster Praesepe are examined by using current photometric rotation periods, spectroscopic rotation velocities, and estimated stellar radii. Three different samples of stellar rotation data on spotted stars from the Galactic field and two independent samples of planetary hosts are used as control samples to support the consistency of the analysis. Considering the high completeness of the Praesepe sample and the behavior of the control samples, we find that the main sequence F - K stars in this cluster are susceptible to rotational axis alignment. Using a cone model, the most likely inclination angle is 76° ± 14° with a half opening angle of 47° ± 24°. Non-isotropic distribution of the inclination angles is preferred over the isotropic distribution, except if the rotation velocities used in this work are systematically overestimated. We found no indication of this being the case on the basis of the currently available data. Data are only available at the CDS, together with the other two compiled datasets used in this paper, via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/612/L2

  6. Bone morphotypes of the varus and valgus knee.

    PubMed

    Thienpont, E; Schwab, P E; Cornu, O; Bellemans, J; Victor, J

    2017-03-01

    Coronal deformity correction with total knee arthroplasty (TKA) is an important feature in the treatment of osteoarthritis (OA). The hypothesis of this study was that bone morphology would be different in varus and valgus deformity, both before osteoarthritis development as well as during and after the disease process of OA. Retrospective study with measurements on preoperative and postoperative full leg standing radiographs of 96 patients who underwent TKA. The included patients were selected for this study because they had an OA knee on one side and a non-arthritic knee on the contralateral side presenting the same type of alignment as the to-be-operated knee (varus or valgus alignment on both sides). The control group of 46 subjects was a group of patients with neutral mechanical alignment who presented for ligamentous problems. A single observer measured mechanical alignment, anatomical alignment, anatomical-mechanical femoral angle and intra-articular bone morphology parameters with an accuracy of 1°. Varus OA group has less distal femoral valgus (mLDFA 89°) than control group (87°) and valgus OA group (mLDFA 85°). Varus OA group has same varus obliquity as control group (MPTA 87°) but more than valgus OA group (MPTA 90°). Joint Line Congruency Angle (JLCA) is 3°open on lateral side in varus and medially open in valgus OA group (2°). The non-arthritic valgus group presents a constitutional mechanical valgus of 184° Hip-Knee-Ankle (HKA) angle. Varus deformity in OA as measured with an HKA angle (HKA) <177° is a combination of distal femoral wear, tibial varus obliquity and lateral joint line opening. Valgus deformity in OA with an HKA > 183° is a combination of femoral distal joint line obliquity and wear combined with medial opening due to medial collateral ligament stretching. The clinical importance of bone morphotype analysis is that it shows the intra-articular potential of alignment correction when mechanical axis cuts are performed. Bone morphology in varus and valgus deformity is different before and after osteoarthritis. Perpendicular cuts to mechanical axes do not necessarily lead to neutral mechanical axis. Constitutional mechanical valgus was observed as 184° HKA angle before the development of OA. Level IV study.

  7. Relationship Between Anterior Lamina Cribrosa Surface Tilt and Glaucoma Development in Myopic Eyes.

    PubMed

    Lee, Eun Jung; Han, Jong Chul; Kee, Changwon

    2017-05-01

    To evaluate the anterior lamina cribrosa (LC) surface tilt angle in myopic eyes and associate it with glaucoma development. In this retrospective study, medical records of myopic patients referred for glaucoma examination from July 1, 2012 to March 30, 2016 were reviewed. Comprehensive ophthalmic examination including spectral-domain optical coherence tomography were performed. We measured the angle of anterior LC surface tilt against Bruch's membrane opening from optical coherence tomography images at the center of the clinical optic disc margin. In horizontal and vertical sections, the angles were defined as α and β, respectively. Patients were grouped according to the presence of glaucomatous damage and factors including optic nerve head morphologic parameters and LC tilt angles were compared between the 2 groups. Among 138 patients originally enrolled, 102 patients were finally analyzed. One eye from 1 patient was randomly chosen. Fifty-five eyes had glaucoma and 47 were normal. The degree of myopia and all optic nerve head morphologic parameters were not significantly different between the 2 groups. However, |α| and |β| were significantly larger in the glaucoma group (all P<0.001), and significances were maintained in multivariate analysis (P<0.001). Larger anterior LC surface tilt angles were related to the presence of glaucoma in normal-pressure myopic eyes. Angulation of the LC against Bruch's membrane opening plane might be associated with increased glaucoma susceptibility in myopic eyes. Further investigations are warranted before clinical utilization of LC tilt as glaucoma susceptibility biomarker.

  8. Open-field arena boundary is a primary object of exploration for Drosophila

    PubMed Central

    Soibam, Benjamin; Mann, Monica; Liu, Lingzhi; Tran, Jessica; Lobaina, Milena; Kang, Yuan Yuan; Gunaratne, Gemunu H; Pletcher, Scott; Roman, Gregg

    2012-01-01

    Drosophila adults, when placed into a novel open-field arena, initially exhibit an elevated level of activity followed by a reduced stable level of spontaneous activity and spend a majority of time near the arena edge, executing motions along the walls. In order to determine the environmental features that are responsible for the initial high activity and wall-following behavior exhibited during exploration, we examined wild-type and visually impaired mutants in arenas with different vertical surfaces. These experiments support the conclusion that the wall-following behavior of Drosophila is best characterized by a preference for the arena boundary, and not thigmotaxis or centrophobicity. In circular arenas, Drosophila mostly move in trajectories with low turn angles. Since the boundary preference could derive from highly linear trajectories, we further developed a simulation program to model the effects of turn angle on the boundary preference. In an hourglass-shaped arena with convex-angled walls that forced a straight versus wall-following choice, the simulation with constrained turn angles predicted general movement across a central gap, whereas Drosophila tend to follow the wall. Hence, low turn angled movement does not drive the boundary preference. Lastly, visually impaired Drosophila demonstrate a defect in attenuation of the elevated initial activity. Interestingly, the visually impaired w1118 activity decay defect can be rescued by increasing the contrast of the arena's edge, suggesting that the activity decay relies on visual detection of the boundary. The arena boundary is, therefore, a primary object of exploration for Drosophila. PMID:22574279

  9. Diagnostic ability of macular ganglion cell-inner plexiform layer thickness in glaucoma suspects.

    PubMed

    Xu, Xiaoyu; Xiao, Hui; Guo, Xinxing; Chen, Xiangxi; Hao, Linlin; Luo, Jingyi; Liu, Xing

    2017-12-01

    The purpose is to assess the diagnostic ability for early glaucoma of macular ganglion cell-inner plexiform layer (GCIPL) thickness in a Chinese population including glaucoma suspects.A total of 367 eyes with primary open-angle glaucoma (168 early glaucoma, 78 moderate glaucoma, and 121 advanced glaucoma), 52 eyes with ocular hypertension (OHT), 59 eyes with enlarged cup-to-disc ratio (C/D), and 225 normal eyes were included. GCIPL thickness (average, minimum, superotemporal, superior, superonasal, inferonasal, inferior, and inferotemporal), retinal nerve fiber layer (RNFL) thickness, and optic nerve head (ONH) parameters were measured using Cirrus high-definition optical coherence tomography (OCT) and compared. The diagnostic ability of OCT parameters was assessed by area under receiver operating characteristic curve (AUROC) in 3 distinguishing groups: normal eyes and eyes with early glaucoma, normal eyes and eyes with glaucoma regardless of disease stage, and nonglaucomatous eyes (normal eyes, eyes with OHT, and enlarged C/D) and early glaucomatous eyes.Glaucomatous eyes showed a significant reduction in GCIPL thickness compared with nonglaucomatous eyes. In all 3 distinguishing groups, best-performing parameters of GCIPL thickness, RNFL thickness, and ONH parameters were minimum GCIPL thickness (expressed in AUROC, 0.899, 0.952, and 0.900, respectively), average RNFL thickness (0.904, 0.953, and 0.892, respectively), and rim area (0.861, 0.925, and 0.824, respectively). There was no statistical significance of AUROC between minimum GCIPL thickness and average RNFL thickness (all P > .05).GCIPL thickness could discriminate early glaucoma from normal and glaucoma suspects with good sensitivity and specificity. The glaucoma diagnostic ability of GCIPL thickness was comparable to that of RNFL thickness. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  10. A brittle-ductile high- and low-angle fault related to the Kea extensional detachment (W Cyclades., Greece)

    NASA Astrophysics Data System (ADS)

    Rockenschaub, M.; Grasemann, B.; Iglseder, C.; Rice, A. H. N.; Schneider, D.; Zamolyi, A.

    2010-05-01

    Roll-back of the African Plate within the Eurasian-African collision zone since the Oligocene/Miocene led to extension in the Cyclades along low-angle normal fault zones and exhumation of rocks from near the brittle-ductile transition zone. On the island of Kea (W Cyclades), which represents such a crustal scale low-angle fault zone with top-to-SSW kinematics, remote sensing analysis of brittle fault lineaments in the Pissis area (W Kea) demonstrates two dominant strike directions: ca. NE-SW and NW-SE. From the north of Pisses southwards, the angle between the two main fault directions changes gradually from a rhombohedral geometry (ca. 50°/130° angle between faults, with the acute angle facing westwards) to an orthogonal geometry. The aim of this study is the development of this fault system. We investigate, if this fault system is related to the Miocene extension or if it is related to a later overprinting event (e.g. the opening of the Corinth) Field observations revealed that the investigated lineaments are high-angle (50-90° dip) brittle/ductile conjugate, faults. Due to the lack of marker layers offsets could only rarely be estimated. Locally centimetre thick marble layers in the greenschists suggest a displacement gradient along the faults with a maximum offset of less than 60 cm. Large displacement gradients are associated with a pronounced ductile fault drag in the host rocks. In some instances, high-angle normal faults were observed to link kinematically with low-angle, top-to-SSW brittle/ductile shear bands. Both the high- and the low-angle faults have a component of ductile shear, which is overprinted by brittle deformation mechanisms. In thin-section, polyphase mode-2 cracks are filled mainly with calcite and quartz (ultra)cataclasites, sometimes followed by further opening with fluid-related iron-rich carbonate (ankeritic) precipitation. CL analysis reveals several generations of cements, indicating multiple phases of cataclastic deformation and fluid infiltration. Ar/Ar white mica data from Pisses constrain ductile deformation to ca. 20 Ma. Since the high-angle faults show a continuum from ductile to brittle deformation, the Ar/Ar cooling ages suggest that faulting must have occurred in the Miocene. Consequently the high-angle faulting was genetically related to the SSW-directed low-angle extensional event and does not represent a later overprint related to a different kinematic event.

  11. Large-angle cosmic microwave background anisotropies in an open universe

    NASA Technical Reports Server (NTRS)

    Kamionkowski, Marc; Spergel, David N.

    1994-01-01

    If the universe is open, scales larger than the curvature scale may be probed by observation of large-angle fluctuations in the cosmic microwave background (CMB). We consider primordial adiabatic perturbations and discuss power spectra that are power laws in volume, wavelength, and eigenvalue of the Laplace operator. Such spectra may have arisen if, for example, the universe underwent a period of `frustated' inflation. The resulting large-angle anisotropies of the CMB are computed. The amplitude generally increases as Omega is decreased but decreases as h is increased. Interestingly enough, for all three Ansaetze, anisotropies on angular scales larger than the curvature scale are suppressed relative to the anisotropies on scales smaller than the curvature scale, but cosmic variance makes discrimination between various models difficult. Models with 0.2 approximately less than Omega h approximately less than 0.3 appear compatible with CMB fluctuations detected by Cosmic Background Explorer Satellite (COBE) and the Tenerife experiment and with the amplitude and spectrum of fluctuations of galaxy counts in the APM, CfA, and 1.2 Jy IRAS surveys. COBE normalization for these models yields sigma(sub 8) approximately = 0.5 - 0.7. Models with smaller values of Omega h when normalized to COBE require bias factors in excess of 2 to be compatible with the observed galaxy counts on the 8/h Mpc scale. Requiring that the age of the universe exceed 10 Gyr implies that Omega approximately greater than 0.25, while requiring that from the last-scattering term in the Sachs-Wolfe formula, large-angle anisotropies come primarily from the decay of potential fluctuations at z approximately less than 1/Omega. Thus, if the universe is open, COBE has been detecting temperature fluctuations produced at moderate redshift rather than at z approximately 1300.

  12. Incidence of secondary glaucoma in behcet disease.

    PubMed

    Elgin, Ufuk; Berker, Nilufer; Batman, Aygen

    2004-12-01

    To determine the incidence of secondary glaucoma in Behcet disease. A total of 230 eyes of 129 patients with Behcet disease, were examined in uveitis and glaucoma clinics of Ankara Social Security Eye Hospital between January 1997 and September 2002. The data from all patients were investigated both retrospectively and prospectively. The mean age of 129 patients was 34.2 +/- 7.4 years (range, 18 to 55 years). In 22 patients (17%), the disease was diagnosed on the basis of the ocular findings, while in the remaining 107 patients (83%), the period between the diagnosis of Behcet disease and the onset of the ocular symptoms was 23.3 +/- 17 months (range, 1 month to 5.3 years); 122 eyes (53%) had the episodes of acute recurrent iridocyclitis, while 108 eyes (47%) developed chronic posterior uveitis, including vitreitis, retinitis, vasculitis, or optic nerve involvement. Secondary glaucoma was diagnosed in 25 eyes (10.9%); 11 eyes (44%) with steroid or inflammation induced open angle glaucoma, 6 eyes (24%) with partial angle-closure glaucoma and peripheral anterior synechiae, 5 eyes (20%) with angle closure glaucoma, peripheral anterior synechiae, and pupil block and 3 eyes (12%) with neovascular glaucoma. The treatments included YAG-laser iridotomy in 5 eyes, diode-laser cyclodestruction in 3 eyes, primary trabeculectomies with mitomycin-c in 4 eyes, secondary trabeculectomies with mitomycin-c in 2 eyes, Ahmed valve implantations in 2 eyes, and cyclocryotherapy in 3 eyes. We suggest that secondary glaucoma is a common and serious complication of Behcet disease. It develops as a result of multiple factors, generally triggered by recurrent intraocular inflammation. Early recognition and treatment of these factors have vital importance to avoid the visual morbidity.

  13. Accuracy of percutaneous pedicle screws for thoracic and lumbar spine fractures compared with open technique.

    PubMed

    Paredes, Igor; Panero, Irene; Cepeda, Santiago; Castaño-Leon, Ana M; Jimenez-Roldan, Luis; Perez-Nuñez, Ángel; Alén, Jose A; Lagares, Alfonso

    2018-06-14

    This study aimed to compare the accuracy of screw placement between open pedicle screw fixation and percutaneous pedicle screw fixation (MIS) for the treatment of thoracolumbar spine fractures (TSF). Forty-nine patients with acute TSF who were treated with transpedicular screw fixation from January 2013 to December 2016 were retrospectively reviewed. The patients were divided into Open and MIS groups. Laminectomy was performed in either group if needed. The accuracy of the screw placement, the evolution of the Cobb sagital angle postoperatively and at 12-month follow up and the neurological status were recorded. AO type of fracture and TLICS score were also recorded. Mean age was 42 years old. Mean TLICS score was 6,29 and 5,96 for open and MIS groups respectively. Twenty five MIS and 24 open surgeries were performed, and 350 (175 in each group) screws were inserted (7,14 per patient). Twenty-four and 13 screws were considered ̈out ̈ in the open and MIS groups respectively (Odds ratio 1,98. 0,97-4,03 p=0,056). The Cobb sagittal angle went from 13,3o to 4,5o and from 14,9o to 8,2o in the Open and MIS groups respectively (both p<0,0001). Loss of correction at 12-month follow up was 3,2o and 4,2o for the open and MIS groups respectively. No neurological worsening was observed. For the treatment of acute thoracolumbar fractures, the MIS technique seems to achieve similar results to the open technique in relation to neurological improvement and deformity correction, while placing the screws more accurately.

  14. High Grazing Angle Sea-Clutter Literature Review

    DTIC Science & Technology

    2013-03-01

    Optimal and sub-optimal detection .................................................................... 37 7.3 Polarimetry ... polarimetry for target detection from high grazing angles. UNCLASSIFIED DSTO-GD-0736 UNCLASSIFIED 36 7.1 Parametric modelling There have not been...relationships were also found to be intrinsically related to Gaussian detection counterparts. 7.3 Polarimetry Early studies by Stacy et al. [45, 46] and

  15. Optimal Control of Airfoil Flow Separation using Fluidic Excitation

    NASA Astrophysics Data System (ADS)

    Shahrabi, Arireza F.

    This thesis deals with the control of flow separation around a symmetric airfoils with the aid of multiple synthetic jet actuators (SJAs). CFD simulation methods have been implemented to uncover the flow separation regimes and associated properties such as frequencies and momentum ratio. In the first part of the study, the SJA was studied thoroughly. Large Eddy Simulations (LES) were performed for one individual cavity; the time history of SJA of the outlet velocity profile and the net momentum imparted to the flow were analyzed. The studied SJA is asymmetrical and operates with the aid of a piezoelectric (PZT) ceramic circular plate actuator. A three-dimensional mesh for the computational domain of the SJA and the surrounding volume was developed and was used to evaluate the details of the airflow conditions inside the SJA as well as at the outlet. The vibration of the PZT ceramic actuator was used as a boundary condition in the computational model to drive the SJA. Particular attention was given to developing a predictive model of the SJA outlet velocity. Results showed that the SJA velocity output is correlated to the PZT ceramic plate vibration, especially for the first frequency mode. SJAs are a particular class of zero net mass flux (ZNMF) fluidic devices with net imparted momentum to the flow. The net momentum imparted to the flow in the separated region is such that positive enhancement during AFC operations is achieved. Flows around the NACA 0015 airfoil were simulated for a range of operating conditions. Attention was given to the active open and closed loop control solutions for an airfoil with SJA at different angles of attack and flap angles. A large number of simulations using RANS & LES models were performed to study the effects of the momentum ratio (Cμ) in the range of 0 to 11% and of the non-dimensional frequency, F+, in the range of 0 to 2 for the control of flow separation at a practical angle of attack and flap angle. The optimum value of Cμ as well as F+ were evaluated and discussed. The computational model predictions showed good agreement with the experimental data. It was observed that different angles of attack and flap angles have different requirements for the minimum value of the momentum coefficient, Cμ, in order for the SJA to be effective for control of separation. It was also found that the variation of F + noticeably affects the lift and drag forces acting on the airfoil. The optimum values of parameters during open loop control simulations have been applied in order to introduce the optimal open loop control outcome. An innovative approach has been implemented to formulate optimal frequencies and momentum ratios of vortex shedding which depends on angle of attack and static pressure of the separation zone in the upper chord. Optimal open loop results have been compared with the optimal closed loop results. Cumulative case studies in the matter of angle of attacks, flap angles, Re, Cμ and F+ provide a convincing collection of evidence to the following conclusion. An improvement of a direct closed loop control was demonstrated, and an analytical formula describing the properties of a separated flow and vortex shedding was proposed. Best AFC solutions are offered by providing optimal frequencies and momentum ratios at a variety of flow conditions.

  16. Short-Term Moderately Elevated Intraocular Pressure Is Associated With Elevated Scotopic Electroretinogram Responses

    PubMed Central

    Choh, Vivian; Gurdita, Akshay; Tan, Bingyao; Prasad, Ratna C.; Bizheva, Kostadinka; Joos, Karen M.

    2016-01-01

    Purpose Moderately elevated intraocular pressure (IOP) is a risk factor for open-angle glaucoma. Some patients suffer glaucoma despite clinically measured normal IOPs. Fluctuations in IOP may have a significant role since IOPs are higher during sleep and inversion activities. Controlled transient elevations of IOPs in rats over time lead to optic nerve structural changes that are similar to the early changes observed in constant chronic models of glaucoma. Because early intervention decreases glaucoma progression, this study was done to determine if early physiological changes to the retina could be detected with noninvasive electrophysiological and optical imaging tests during moderately elevated IOP. Methods Intraocular pressures were raised to moderately high levels (35 mm Hg) in one eye of Sprague-Dawley rats while the other (control) eye was untreated. One group of rats underwent scotopic threshold response (STR) and electroretinogram (ERG) testing, while another 3 groups underwent optical coherence tomography (OCT) imaging, Western blot, or histologic evaluation. Results The amplitudes of the STR and ERG responses in eyes with moderately elevated IOPs were enhanced compared to the values before IOP elevation, and compared to untreated contralateral eyes. Structural changes to the optic nerve also occurred during IOP elevation. Conclusions Although ischemic IOP elevations are well-known to globally reduce components of the scotopic ERG, acute elevation in rats to levels often observed in untreated glaucoma patients caused an increase in these parameters. Further exploration of these phenomena may be helpful in better understanding the mechanisms mediating early retinal changes during fluctuating or chronically elevated IOP. PMID:27100161

  17. Pulsar perimetry in the diagnosis of early glaucoma.

    PubMed

    Zeppieri, Marco; Brusini, Paolo; Parisi, Lucia; Johnson, Chris A; Sampaolesi, Roberto; Salvetat, Maria Letizia

    2010-01-01

    To assess the ability of Pulsar perimetry (Pulsar) in detecting early glaucomatous visual field (VF) damage in comparison with Frequency Doubling Technology (FDT), Scanning Laser Polarimetry (SLP, GDx VCC), and Heidelberg Retina Tomography (HRT). Prospective observational cross-sectional case study. This multicenter study included: 87 ocular hypertensives (OHT); 67 glaucomatous optic neuropathy (GON) patients; 75 primary open-angle glaucoma (POAG) patients; and 90 normals. All patients underwent standard automated perimetry (SAP) HFA 30-2, Pulsar T30W, FDT N-30, HRT II, and GDx VCC. Area under Receiver Operating Characteristic Curves (AROCs) for discriminating between healthy and glaucomatous eyes and agreement among instruments were determined. The best parameters for Pulsar, FDT, HRT, and GDx were, respectively: loss variance square root; no. of areas with P< 5%; Cup-Shape-Measure; and Nerve Fiber Indicator (NFI). In detecting POAG eyes, Pulsar (AROC, 0.90) appeared comparable with FDT (0.89) and significantly better than HRT (0.82) and GDx (0.79). For GON, Pulsar ability (0.74) was higher than GDx (0.69) and lower than FDT (0.80) and HRT (0.83). The agreement among instruments ranged from 0.12 to 0.56. Pulsar test duration was significantly shorter than SAP and FDT (P< .001). Pulsar T30W test is a rapid and easy perimetric method, showing higher sensitivity than SAP in detecting early glaucomatous VF loss. Its diagnostic ability is good for detecting early perimetric POAG eyes and fair for GON eyes. Pulsar performance was comparable with FDT, HRT, and GDx, even if the agreement between instruments was poor to fair. Copyright 2010 Elsevier Inc. All rights reserved.

  18. An Open Letter to Premier Wen Jiabao

    ERIC Educational Resources Information Center

    Chinese Education and Society, 2008

    2008-01-01

    This article is an open letter of a group of early childhood education (ECE) practitioners to Premier Wen Jiabao. This open letter was written with one goal in mind: to ask Premier Wen's government to take measures to protect young children and support early childhood education. These practitioners have become worried about the many accidents that…

  19. Open Listening: Creative Evolution in Early Childhood Settings

    ERIC Educational Resources Information Center

    Davies, Bronwyn

    2011-01-01

    This article sketches out a philosophy and practice of open listening, linking open listening to Bergson's (1998) concept of creative evolution. I draw on examples of small children at play from a variety of sources, including Reggio-Emilia-inspired preschools in Sweden. The article offers a challenge to early childhood educators to listen and to…

  20. The effect of transverse crack upon parametric instability of a rotor-bearing system with an asymmetric disk

    NASA Astrophysics Data System (ADS)

    Han, Qinkai; Chu, Fulei

    2012-12-01

    It is well known that either the asymmetric disk or transverse crack brings parametric inertia (or stiffness) excitation to the rotor-bearing system. When both of them appear in a rotor system, the parametric instability behaviors have not gained sufficient attentions. Thus, the effect of transverse crack upon parametric instability of a rotor-bearing system with an asymmetric disk is studied. First, the finite element equations of motion are established for the asymmetric rotor system. Both the open and breathing transverse cracks are taken into account in the model. Then, the discrete state transition matrix (DSTM) method is introduced for numerically acquiring the instability regions. Based upon these, some computations for a practical asymmetric rotor system with open or breathing transverse crack are conducted, respectively. Variations of the primary and combination instability regions induced by the asymmetric disk with the crack depth are observed, and the effect of the orientation angle between the crack and asymmetric disk on various instability regions are discussed in detail. It is shown that for the asymmetric angle around 0, the existence of transverse (either open or breathing) crack has attenuation effect upon the instability regions. Under certain crack depth, the instability regions could be vanished by the transverse crack. When the asymmetric angle is around π/2, increasing the crack depth would enhance the instability regions.

  1. Exclusion of candidate genes from the chromosome 1q juvenile glaucoma region and mapping of the peripheral cannabis receptor gene (CNR2) to chromosome 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sunden, S.L.F.; Nichols, B.E.; Alward, W.L.M.

    Juvenile onset primary open angle glaucoma has been mapped by linkage to 1q21-q31. Several candidate genes were evaluated in the same family used to identify the primary linkage. Atrionatriuretic peptide receptor A (NPR1) and laminin C1 (LAMC1) have been previously mapped to this region and could putatively play a role in the pathogenesis of glaucoma. A third gene, the peripheral cannabis receptor (CNR2) was not initially mapped in humans but was a candidate because of the relief that cannabis affords some patients with primary open angle glaucoma. Microsatellites associated with NPR1 and LAMC1 revealed multiple recombinations in affected members ofmore » this pedigree. CNR2 was shown to be on chromosome 1 by PCR amplification of a 150 bp fragment of the 3{prime} untranslated region in monochromosomal somatic cell hybrids (NIGMS panel No. 2). These primers also revealed a two allele single strand conformation polymorphism which showed multiple recombinants with juvenile onset primary open angle glaucoma in large pedigrees, segregating this disorder. The marker was then mapped to 1p34-p36 by linkage, with the most likely location between liver alkaline phosphatase (ALPL) and alpha-L-1 fucosidase (FUCA1).« less

  2. Application of Bayes' to the prediction of referral decisions made by specialist optometrists in relation to chronic open angle glaucoma.

    PubMed

    Gurney, J C; Ansari, E; Harle, D; O'Kane, N; Sagar, R V; Dunne, M C M

    2018-02-09

    To determine the accuracy of a Bayesian learning scheme (Bayes') applied to the prediction of clinical decisions made by specialist optometrists in relation to the referral refinement of chronic open angle glaucoma. This cross-sectional observational study involved collection of data from the worst affected or right eyes of a consecutive sample of cases (n = 1,006) referred into the West Kent Clinical Commissioning Group Community Ophthalmology Team (COT) by high street optometrists. Multilevel classification of each case was based on race, sex, age, family history of chronic open angle glaucoma, reason for referral, Goldmann Applanation Tonometry (intraocular pressure and interocular asymmetry), optic nerve head assessment (vertical size, cup disc ratio and interocular asymmetry), central corneal thickness and visual field analysis (Hodapp-Parrish-Anderson classification). Randomised stratified tenfold cross-validation was applied to determine the accuracy of Bayes' by comparing its output to the clinical decisions of three COT specialist optometrists; namely, the decision to discharge, follow-up or refer each case. Outcomes of cross-validation, expressed as means and standard deviations, showed that the accuracy of Bayes' was high (95%, 2.0%) but that it falsely discharged (3.4%, 1.6%) or referred (3.1%, 1.5%) some cases. The results indicate that Bayes' has the potential to augment the decisions of specialist optometrists.

  3. Anterior Chamber Angle Shape Analysis and Classification of Glaucoma in SS-OCT Images.

    PubMed

    Ni Ni, Soe; Tian, J; Marziliano, Pina; Wong, Hong-Tym

    2014-01-01

    Optical coherence tomography is a high resolution, rapid, and noninvasive diagnostic tool for angle closure glaucoma. In this paper, we present a new strategy for the classification of the angle closure glaucoma using morphological shape analysis of the iridocorneal angle. The angle structure configuration is quantified by the following six features: (1) mean of the continuous measurement of the angle opening distance; (2) area of the trapezoidal profile of the iridocorneal angle centered at Schwalbe's line; (3) mean of the iris curvature from the extracted iris image; (4) complex shape descriptor, fractal dimension, to quantify the complexity, or changes of iridocorneal angle; (5) ellipticity moment shape descriptor; and (6) triangularity moment shape descriptor. Then, the fuzzy k nearest neighbor (fkNN) classifier is utilized for classification of angle closure glaucoma. Two hundred and sixty-four swept source optical coherence tomography (SS-OCT) images from 148 patients were analyzed in this study. From the experimental results, the fkNN reveals the best classification accuracy (99.11 ± 0.76%) and AUC (0.98 ± 0.012) with the combination of fractal dimension and biometric parameters. It showed that the proposed approach has promising potential to become a computer aided diagnostic tool for angle closure glaucoma (ACG) disease.

  4. Comparison of Salter osteotomy and Tonnis lateral acetabuloplasty with simultaneous open reduction for the treatment of developmental dysplasia of the hip: midterm results.

    PubMed

    Bayhan, Ilhan A; Beng, Kubilay; Yildirim, Timur; Akpinar, Evren; Ozcan, Cagri; Yagmurlu, Firat

    2016-11-01

    The aim of this study was to compare the midterm clinical and radiological outcomes of the Salter osteotomy (SO) and Tonnis lateral acetabuloplasty (TLA) with concomitant open reduction for the treatment of developmental dysplasia of the hip. Twenty-five hips of 20 patients who underwent SO with open reduction and 26 hips of 23 patients who underwent TLA with open reduction were evaluated retrospectively. The average age of the patients at the time of the operation was 35.6 months in the SO and 36.6 months in the TLA group, without a statistically significant difference (P=0.836). The average follow-up times in the SO and TLA groups were 59.9 and 54.8 months, respectively (P=0.397). Preoperative (40.6° in the SO vs. 42.2° in the TLA, P=0.451) and last follow-up acetabular index (12° in the SO vs. 14° in the TLA, P=0.227) and center-edge angle measurements (30° in the SO vs. 26° in the TLA, P=0.069) did not show a statistically significant difference between the SO and TLA groups; however, early postoperative acetabular index improvement was better in the TLA group than in the SO group (21.2° in the SO vs. 17.2° in the TLA, P=0.014). According to the Severin grading system, both groups showed a similar number of good outcomes without a statistically significant difference (P=0.936). Clinical assessment on the basis of McKay's criteria showed similar good and excellent outcomes (P=0.936). Both osteotomy techniques showed similar satisfactory outcomes for the treatment of DDH in patients older than 18 months of age.

  5. Wicket gate trailing-edge blowing: A method for improving off-design hydroturbine performance by adjusting the runner inlet swirl angle

    NASA Astrophysics Data System (ADS)

    Lewis, B. J.; Cimbala, J. M.; Wouden, A. M.

    2014-03-01

    At their best efficiency point (BEP), hydroturbines operate at very high efficiency. However, with the ever-increasing penetration of alternative electricity generation, it has become common to operate hydroturbines at off-design conditions in order to maintain stability in the electric power grid. This paper demonstrates a method for improving hydroturbine performance during off-design operation by injecting water through slots at the trailing edges of the wicket gates. The injected water causes a change in bulk flow direction at the inlet of the runner. This change in flow angle from the wicket gate trailing-edge jets provides the capability of independently varying the flow rate and swirl angle through the runner, which in current designs are both determined by the wicket gate opening angle. When properly tuned, altering the flow angle results in a significant improvement in turbine efficiency during off-design operation.

  6. Evaluation of eyes with relative pupillary block by indentation ultrasound biomicroscopy gonioscopy.

    PubMed

    Matsunaga, Koichi; Ito, Kunio; Esaki, Koji; Sugimoto, Kota; Sano, Toru; Miura, Katsuya; Sasoh, Mikio; Uji, Yukitaka

    2004-03-01

    To investigate changes in anterior chamber angle configuration with indentation ultrasound biomicroscopy gonioscopy of relative pupillary block (RPB). Cross-sectional study. This study included 26 eyes of 26 patients with RPB. We determined angle opening distance 500 and angle recess area using indentation ultrasound biomicroscopy gonioscopy and compared a small-sized standard eye cup with a new eye cup with an area for inducing pressure. Indentation ultrasound biomicroscopy images documented concavity of the iris in eyes with RPB. Both the new and the small standard eye cups widened the anterior chamber angle significantly (P <.0001) without causing corneal damage. Angle changes were significantly greater for the new eye cup design. Indentation ultrasound biomicroscopy gonioscopy is a useful technique for observation and diagnosis of RPB. Using a small standard or the newly designed eye cup, the procedure can be performed easily and without causing corneal damage.

  7. Angle stations in or for endless conveyor belts

    DOEpatents

    Steel, Alan

    1987-04-07

    In an angle station for an endless conveyor belt, there are presented to each incoming run of the belt stationary curved guide members (18, 19) of the shape of a major segment of a right-circular cylinder and having in the part-cylindrical portion (16 or 17) thereof rectangular openings (15) arranged in parallel and helical paths and through which project small freely-rotatable rollers (14), the continuously-changing segments of the curved surfaces of which projecting through said openings (15) are in attitude to change the direction of travel of the belt (13) through 90.degree. during passage of the belt about the part-cylindrical portion (16 or 17) of the guide member (18 or 19). The rectangular openings (15) are arranged with their longer edges lengthwise of the diagonals representing the mean of the helix but with those of a plurality of the rows nearest to each end of the part-cylindrical portion (16 or 17) slightly out of axial symmetry with said diagonals, being slightly inclined in a direction about the intersections (40) of the diagonals of the main portion of the openings, to provide a "toe-in" attitude in relation to the line of run of the endless conveyor belt.

  8. Tectonic Evolution of Mozambique Ridge in East African continental margin

    NASA Astrophysics Data System (ADS)

    Tang, Yong

    2017-04-01

    Tectonic Evolution of Mozambique Ridge in East African continental margin Yong Tang He Li ES.Mahanjane Second Institute of Oceanography,SOA,Hangzhou The East Africa passive continental margin is a depression area, with widely distributed sedimentary wedges from southern Mozambique to northern Somali (>6500km in length, and about 6km in thickness). It was resulted from the separation of East Gondwana, and was developed by three stages: (1) rifting in Early-Middle Jurassic; (2) spreading from Late Jurassic to Early Cretaceous; (3) drifting since the Cretaceous period. Tectonic evolution of the Mozambique continental margin is distinguished by two main settings separated by a fossil transform, the Davie Fracture Zone; (i) rifting and transform setting in the northern margin related to opening of the Somali and Rovuma basins, and (ii) rifting and volcanism setting during the opening of the Mozambique basin in the southern margin. 2D reflection seismic investigation of the crustal structure in the Zambezi Delta Depression, provided key piece of evidence for two rifting phases between Africa and Antarctica. The magma-rich Rift I phase evolved from rift-rift-rift style with remarkable emplacement of dyke swarms (between 182 and 170 Ma). Related onshore outcrops are extensively studied, the Karoo volcanics in Mozambique, Zimbabwe and South Africa, all part of the Karoo "triple-junction". These igneous bodies flow and thicken eastwards and are now covered by up to 5 km of Cretaceous and Tertiary sediments and recorded by seismic and oil exploration wells. Geophysical and geological data recorded during oceanographic cruises provide very controversial results regarding the nature of the Mozambique Ridge. Two conflicting opinions remains open, since the early expeditions to the Indian Ocean, postulating that its character is either magmatic (oceanic) or continental origin. We have carried out an China-Mozambique Joint Cruise(CMJC) on southern Mozambique Basin on 1st June to 23rd June,2017. The CMJC used multi-beam bathymetric, sub-bottom profiling, multi-channel reflection seismic, wide-angle refraction and Gravity to collect data. The preliminary new findings include: (1) the thick-layer sediments during Tertiary and Cretaceous; (2) the southern continental margin mainly affected by the rifting and volcanism during the stages of the Mozambique Basin formation; (3) the Cretaceous sediments located along the Mozambique Basin in both marine and continental environment.

  9. Femoral condyle curvature is correlated with knee walking kinematics in ungulates.

    PubMed

    Sylvester, Adam D

    2015-12-01

    The knee has been the focus of many studies linking mammalian postcranial form with locomotor behaviors and animal ecology. A more difficult task has been linking joint morphology with joint kinematics during locomotor tasks. Joint curvature represents one opportunity to link postcranial morphology with walking kinematics because joint curvature develops in response to mechanical loading. As an initial examination of mammalian knee joint curvature, the curvature of the medial femoral condyle was measured on femora representing 11 ungulate species. The position of a region of low curvature was measured using a metric termed the "angle to low curvature". This low-curvature region is important because it provides the greatest contact area between femoral and tibial condyles. Kinematic knee angles during walking were derived from the literature and kinematic knee angles across the gait cycle were correlated with angle to low curvature values. The highest correlation between kinematic knee angle and the angle to low curvature metric occurred at 20% of the walking gait cycle. This early portion of the walking gait cycle is associated with a peak in the vertical ground reaction force for some mammals. The chondral modeling theory predicts that frequent and heavy loading of particular regions of a joint surface during ontogeny will result in these regions being flatter than the surrounding joint surface. The locations of flatter regions of the femoral condyles of ungulates, and their association with knee angles used during the early stance phase of walking provides support for the chondral modeling theory. © 2015 Wiley Periodicals, Inc.

  10. Spatiotemporal distribution of location and object effects in reach-to-grasp kinematics

    PubMed Central

    Rouse, Adam G.

    2015-01-01

    In reaching to grasp an object, the arm transports the hand to the intended location as the hand shapes to grasp the object. Prior studies that tracked arm endpoint and grip aperture have shown that reaching and grasping, while proceeding in parallel, are interdependent to some degree. Other studies of reaching and grasping that have examined the joint angles of all five digits as the hand shapes to grasp various objects have not tracked the joint angles of the arm as well. We, therefore, examined 22 joint angles from the shoulder to the five digits as monkeys reached, grasped, and manipulated in a task that dissociated location and object. We quantified the extent to which each angle varied depending on location, on object, and on their interaction, all as a function of time. Although joint angles varied depending on both location and object beginning early in the movement, an early phase of location effects in joint angles from the shoulder to the digits was followed by a later phase in which object effects predominated at all joint angles distal to the shoulder. Interaction effects were relatively small throughout the reach-to-grasp. Whereas reach trajectory was influenced substantially by the object, grasp shape was comparatively invariant to location. Our observations suggest that neural control of reach-to-grasp may occur largely in two sequential phases: the first determining the location to which the arm transports the hand, and the second shaping the entire upper extremity to grasp and manipulate the object. PMID:26445870

  11. Monitoring of unstable slopes by MEMS tilting sensors and its application to early warning

    NASA Astrophysics Data System (ADS)

    Towhata, I.; Uchimura, T.; Seko, I.; Wang, L.

    2015-09-01

    The present paper addresses the newly developed early warning technology that can help mitigate the slope failure disasters during heavy rains. Many studies have been carried out in the recent times on early warning that is based on rainfall records. Although those rainfall criteria of slope failure tells the probability of disaster on a regional scale, it is difficult for them to judge the risk of particular slopes. This is because the rainfall intensity is spatially too variable to forecast and the early warning based on rainfall alone cannot take into account the effects of local geology, hydrology and topography that vary spatially as well. In this regard, the authors developed an alternative technology in which the slope displacement/deformation is monitored and early warning is issued when a new criterion is satisfied. The new MEMS-based sensor monitors the tilting angle of an instrument that is embedded at a very shallow depth and the record of the tilting angle corresponds to the lateral displacement at the slope surface. Thus, the rate of tilting angle that exceeds a new criterion value implies an imminent slope failure. This technology has been validated against several events of slope failures as well as against a field rainfall test. Those validations have made it possible to determine the criterion value of the rate of tilting angle to be 0.1 degree/hour. The advantage of the MEMS tilting sensor lies in its low cost. Hence, it is possible to install many low-cost sensors over a suspected slope in which the precise range of what is going to fall down during the next rainfall is unknown. In addition to the past validations, this paper also introduces a recent application to a failed slope in the Izu Oshima Island where a heavy rainfall-induced slope failure occurred in October, 2013.

  12. Macular Choroidal Small-Vessel Layer, Sattler's Layer and Haller's Layer Thicknesses: The Beijing Eye Study.

    PubMed

    Zhao, Jing; Wang, Ya Xing; Zhang, Qi; Wei, Wen Bin; Xu, Liang; Jonas, Jost B

    2018-03-13

    To study macular choroidal layer thickness, 3187 study participants from the population-based Beijing Eye Study underwent spectral-domain optical coherence tomography with enhanced depth imaging for thickness measurements of the macular small-vessel layer, including the choriocapillaris, medium-sized choroidal vessel layer (Sattler's layer) and large choroidal vessel layer (Haller's layer). In multivariate analysis, greater thickness of all three choroidal layers was associated (all P < 0.05) with higher prevalence of age-related macular degeneration (AMD) (except for geographic atrophy), while it was not significantly (all P > 0.05) associated with the prevalence of open-angle glaucoma or diabetic retinopathy. There was a tendency (0.07 > P > 0.02) toward thinner choroidal layers in chronic angle-closure glaucoma. The ratio of small-vessel layer thickness to total choroidal thickness increased (P < 0.001; multivariate analysis) with older age and longer axial length, while the ratios of Sattler's layer and Haller's layer thickness to total choroidal thickness decreased. A higher ratio of small-vessel layer thickness to total choroidal thickness was significantly associated with a lower prevalence of AMD (early type, intermediate type, late geographic type). Axial elongation-associated and aging-associated choroidal thinning affected Haller's and Sattler's layers more markedly than the small-vessel layer. Non-exudative and exudative AMD, except for geographic atrophy, was associated with slightly increased choroidal thickness.

  13. Optical coherence tomography in anterior segment imaging

    PubMed Central

    Kalev-Landoy, Maya; Day, Alexander C.; Cordeiro, M. Francesca; Migdal, Clive

    2008-01-01

    Purpose To evaluate the ability of optical coherence tomography (OCT), designed primarily to image the posterior segment, to visualize the anterior chamber angle (ACA) in patients with different angle configurations. Methods In a prospective observational study, the anterior segments of 26 eyes of 26 patients were imaged using the Zeiss Stratus OCT, model 3000. Imaging of the anterior segment was achieved by adjusting the focusing control on the Stratus OCT. A total of 16 patients had abnormal angle configurations including narrow or closed angles and plateau irides, and 10 had normal angle configurations as determined by prior full ophthalmic examination, including slit-lamp biomicroscopy and gonioscopy. Results In all cases, OCT provided high-resolution information regarding iris configuration. The ACA itself was clearly visualized in patients with narrow or closed angles, but not in patients with open angles. Conclusions Stratus OCT offers a non-contact, convenient and rapid method of assessing the configuration of the anterior chamber. Despite its limitations, it may be of help during the routine clinical assessment and treatment of patients with glaucoma, particularly when gonioscopy is not possible or difficult to interpret. PMID:17355288

  14. Influence of crack opening and incident wave angle on second harmonic generation of Lamb waves

    NASA Astrophysics Data System (ADS)

    Yang, Yi; Ng, Ching-Tai; Kotousov, Andrei

    2018-05-01

    Techniques utilising second harmonic generation (SHG) have proven their great potential in detecting contact-type damage. However, the gap between the practical applications and laboratory studies is still quite large. The current work is aimed to bridge this gap by investigating the effects of the applied load and incident wave angle on the detectability of fatigue cracks at various lengths. Both effects are critical for practical implementations of these techniques. The present experimental study supported by three-dimensional (3D) finite element (FE) modelling has demonstrated that the applied load, which changes the crack opening and, subsequently, the contact nonlinearity, significantly affects the amplitude of the second harmonic generated by the fundamental symmetric mode (S0) of Lamb wave. This amplitude is also dependent on the length of the fatigue crack as well as the incident wave angle. The experimental and FE results correlate well, so the modelling approach can be implemented for practical design of damage monitoring systems as well as for the evaluation of the severity of the fatigue cracks.

  15. Variability of single-leg versus double-leg stance radiographs in the varus knee.

    PubMed

    Chen, Andrew; Rich, Valerie; Bain, Elizabeth; Sterett, William I

    2009-07-01

    We evaluated measured radiographic parameter variability between single-leg stance (SLS) and double-leg stance (DLS) radiographs in patients with varus knee malalignment, indicated for high tibial osteotomy. Fifty-three consecutive knees (mean, 49 years; range, 18-79 years) were evaluated for varus thrust. SLS and DLS radiographs were obtained. A single blinded observer measured mechanical axis angles and weight-bearing line (WBL) deviation using a goniometer. Mechanical axis angles averaged 9.1 degrees (DLS) and 11.3 degrees (SLS). SLS radiographs averaged 9% greater WBL medialization than did DLS. Medial opening averaged 16.4 mm (DLS) and 18.8 mm (SLS). DLS and SLS radiographs showed no significant differences in patients without varus thrust. Patients with varus thrust demonstrated differences in mechanical axis angles (DLS, 9.4 degrees; SLS, 12.2 degrees), WBL deviation (12.1% less), medialization (DLS), and medial opening necessary for correction (DLS, 16.6 mm; SLS, 20.3 mm). In varus thrust, SLS radiographs more closely replicate dynamic knee malalignment, possibly providing more accurate measurements of angular deformity.

  16. Optimizing water permeability through the hourglass shape of aquaporins

    PubMed Central

    Gravelle, Simon; Joly, Laurent; Detcheverry, François; Ybert, Christophe; Cottin-Bizonne, Cécile; Bocquet, Lydéric

    2013-01-01

    The ubiquitous aquaporin channels are able to conduct water across cell membranes, combining the seemingly antagonist functions of a very high selectivity with a remarkable permeability. Whereas molecular details are obvious keys to perform these tasks, the overall efficiency of transport in such nanopores is also strongly limited by viscous dissipation arising at the connection between the nanoconstriction and the nearby bulk reservoirs. In this contribution, we focus on these so-called entrance effects and specifically examine whether the characteristic hourglass shape of aquaporins may arise from a geometrical optimum for such hydrodynamic dissipation. Using a combination of finite-element calculations and analytical modeling, we show that conical entrances with suitable opening angle can indeed provide a large increase of the overall channel permeability. Moreover, the optimal opening angles that maximize the permeability are found to compare well with the angles measured in a large variety of aquaporins. This suggests that the hourglass shape of aquaporins could be the result of a natural selection process toward optimal hydrodynamic transport. Finally, in a biomimetic perspective, these results provide guidelines to design artificial nanopores with optimal performances. PMID:24067650

  17. Effects of excimer laser illumination on microdrilling into an oblique polymer surface

    NASA Astrophysics Data System (ADS)

    Wu, Chih-Yang; Shu, Chun-Wei; Yeh, Zhi-Chang

    2006-08-01

    In this work, we present the experimental results of micromachining into polymethy-methacrylate exposed to oblique KrF excimer laser beams. The results of low-aspect-ratio ablations show that the ablation rate decreases monotonously with the increase of incident angle for various fluences. The ablation rate of high-aspect-ratio drilling with opening center on the focal plane is almost independent of incident angles and is less than that of low-aspect-ratio ablation. The results of high-aspect-ratio ablations show that the openings of the holes at a distance from the focal plane are enlarged and their edges are blurred. Besides, the depth of a hole in the samples oblique to the laser beam at a distance from the focal plane decreases with the increase of the distance from the focal plane. The number of deep holes generated by oblique laser beams through a matrix of apertures decreases with the increase of incident angle. Those phenomena reveal the influence of the local light intensity on microdrilling into an oblique surface.

  18. A New Approach to Micro-arcsecond Astrometry with SIM Allowing Early Mission Narrow Angle Measurements of Compelling Astronomical Targets

    NASA Technical Reports Server (NTRS)

    Shaklan, Stuart; Pan, Xiaopei

    2004-01-01

    The Space Interferometry Mission (SIM) is capable of detecting and measuring the mass of terrestrial planets around stars other than our own. It can measure the mass of black holes and the visual orbits of radio and x-ray binary sources. SIM makes possible a new level of understanding of complex astrophysical processes. SIM achieves its high precision in the so-called narrow-angle regime. This is defined by a 1 degree diameter field in which the position of a target star is measured with respect to a set of reference stars. The observation is performed in two parts: first, SIM observes a grid of stars that spans the full sky. After a few years, repeated observations of the grid allow one to determine the orientation of the interferometer baseline. Second, throughout the mission, SIM periodically observes in the narrow-angle mode. Every narrow-angle observation is linked to the grid to determine the precise attitude and length of the baseline. The narrow angle process demands patience. It is not until five years after launch that SIM achieves its ultimate accuracy of 1 microarcsecond. The accuracy is degraded by a factor of approx. 2 at mid-mission. Our work proposes a technique for narrow angle astrometry that does not rely on the measurement of grid stars. This technique, called Gridless Narrow Angle Astrometry (GNAA) can obtain microarcsecond accuracy and can detect extra-solar planets and other exciting objects with a few days of observation. It can be applied as early as during the first six months of in-orbit calibration (IOC). The motivations for doing this are strong. First, and obviously, it is an insurance policy against a catastrophic mid-mission failure. Second, at the start of the mission, with several space-based interferometers in the planning or implementation phase, NASA will be eager to capture the public's imagination with interferometric science. Third, early results and a technique that can duplicate those results throughout the mission will give the analysts important experience in the proper use and calibration of SIM.

  19. Initial Investigation of the Acoustics of a Counter-Rotating Open Rotor Model with Historical Baseline Blades in a Low-Speed Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Elliott, David M.

    2012-01-01

    A counter-rotating open rotor scale model was tested in the NASA Glenn Research Center 9- by 15-Foot Low-Speed Wind Tunnel (LSWT). This model used a historical baseline blade set with which modern blade designs will be compared against on an acoustic and aerodynamic performance basis. Different blade pitch angles simulating approach and takeoff conditions were tested, along with angle-of-attack configurations. A configuration was also tested in order to determine the acoustic effects of a pylon. The shaft speed was varied for each configuration in order to get data over a range of operability. The freestream Mach number was also varied for some configurations. Sideline acoustic data were taken for each of these test configurations.

  20. Strong-field ionization with twisted laser pulses

    NASA Astrophysics Data System (ADS)

    Paufler, Willi; Böning, Birger; Fritzsche, Stephan

    2018-04-01

    We apply quantum trajectory Monte Carlo computations in order to model strong-field ionization of atoms by twisted Bessel pulses and calculate photoelectron momentum distributions (PEMD). Since Bessel beams can be considered as an infinite superposition of circularly polarized plane waves with the same helicity, whose wave vectors lie on a cone, we compared the PEMD of such Bessel pulses to those of a circularly polarized pulse. We focus on the momentum distributions in propagation direction of the pulse and show how these momentum distributions are affected by experimental accessible parameters, such as the opening angle of the beam or the impact parameter of the atom with regard to the beam axis. In particular, we show that we can find higher momenta of the photoelectrons, if the opening angle is increased.

  1. Educating the glaucoma patient.

    PubMed Central

    Rosenthal, A. R.; Zimmerman, J. F.; Tanner, J.

    1983-01-01

    Forty-nine patients with open-angle glaucoma and 32 controls were studied at each of 2 medical centres, one in California and one in England. A 12-point questionnaire was answered before, immediately after, and 6 months after viewing a 6 minute video film about glaucoma. The English glaucoma patients and controls showed lower initial knowledge than their American counterparts. Immediately after the film all groups had substantially improved their knowledge by answering 78-88% of the questions correctly. Recall study showed that both American groups had retained more than their British counterparts and that glaucoma patients retained more knowledge of their disease than did controls. The use of an educational video film in an outpatient setting is a simple and economical method of patient education applicable to both American and British subjects with open-angle glaucoma. PMID:6671096

  2. On the 'flip-flop' instability of Bondi-Hoyle accretion flows

    NASA Technical Reports Server (NTRS)

    Livio, Mario; Soker, Noam; Matsuda, Takuya; Anzer, Ulrich

    1991-01-01

    A simple physical interpretation is advanced by means of an analysis of the shock cone in the accretion flows past a compact object and with an examination of the accretion-line stability analyses. The stability of the conical shock is examined against small angular deflections with attention given to several simplifying assumptions. A line instability is identified in the Bondi-Hoyle accretion flows that leads to the formation of a large opening-angle shock. When the opening angle becomes large the instability becomes irregular oscillation. The analytical methodology is compared to previous numerical configurations that demonstrate different shock morphologies. The Bondi-Hoyle accretion onto a compact object is concluded to generate a range of nonlinear instabilities in both homogeneous and inhomogeneous cases with a quasiperiodic oscillation in the linear regime.

  3. Role of oxidative stress enzymes in open-angle glaucoma.

    PubMed

    Yildirim, O; Ateş, N A; Ercan, B; Muşlu, N; Unlü, A; Tamer, L; Atik, U; Kanik, A

    2005-05-01

    To investigate the role of oxidative stress and lipid peroxidation in the pathogenesis of primary open-angle glaucoma (POAG). The activities of myeloperoxidase (MPO), catalase (CAT), and the levels of plasma malondialdehyde (MDA) were measured in 40 (15 men and 25 women) patients with POAG and 60 (30 men and 30 women) healthy controls. There was no significant difference in the activities of CAT and MPO between the POAG patients and the controls. However, the plasma MDA level was significantly higher in patients than the controls. The results of this preliminary study suggest that the possible alterations of plasma MDA levels may be associated with the pathogenesis of POAG, but further research is needed to understand the role of oxidative damage in this important disorder of aging.

  4. [Characteristics in treatment of the hip in patients with Down syndrome].

    PubMed

    Peterlein, C-D; Schiel, M; Timmesfeld, N; Schofer, M D; Eberhardt, O; Wirth, T; Fernandez, F F

    2013-12-01

    The treatment of hip instability in patients with Down syndrome is challenging. We have performed different pelvic osteotomies and corrections at the proximal femur for this indication. This retrospective study was conducted to evaluate the clinical and radiological outcome of each intervention. All in all, 166 patients with Down syndrome were treated at our orthopaedic department in the observation period. Problems related to the hip joint were diagnosed in 63 of those patients. Only patients who underwent surgery were included in this study. The charts and X-rays of these 31 patients were evaluated with respect to the following parameters: incidence of the hip problem, concomitant diseases, temporal progress, kind of operation method and date, duration of stay in the hospital, after-care, follow-on surgery related to complications, AC angle, CE angle, ACM angle, CCD angle, index of migration according to Reimers, classification of Bauer and Kerschbauer and general morphology of the femoral head. The group was compared with an age-matched group of 21 patients with hip dysplasia. Those patients underwent the same sort of operation in the same year. In the Morbus Down group, we performed surgery for preservation of the hip in 49 cases. This included 13 osteotomies according to Chiari, 11 triple osteotomies according to Tönnis, 10 corrections by femoral varus derotation osteotomy, 8 pelvic osteotomies according to Pemberton, 5 pelvic osteotomies according to Salter and 2 open reductions of the hip. With respect to the moment of surgery, we detected three peaks of age. There was no difference in course of disease and quantity of complications between the groups. Satisfactory results concerning clinical and radiological outcome were achieved predominantly by complete redirectional acetabular osteotomies. Half of the patients who were solely treated by femoral varus derotation osteotomy needed follow-on surgery in the form of pelvic osteotomy. Comparison of preoperative and postoperative range of motion of the hip joint between groups detected capsular insufficiency, increased ligamentous laxity and muscular hypotonia in patients with Down syndrome. Comparison of pelvic radiographs demonstrated significant improvement concerning measured angles in both groups. Preoperative values with respect to AC angle and CE angle were demonstrated to be lower in the hip dysplasia group (p < 0.01); whereas values for ACM angle were comparable between groups. Hypermobility and secondary dislocation of the hip joint is a common problem in patients with Down syndrome, which often requires surgical intervention at an early stage. According to our data and clinical results we suggest a complete redirectional acetabular osteotomy in combination with capsular plication for treatment of this challenging condition. Georg Thieme Verlag KG Stuttgart · New York.

  5. Three-dimensional orientation and location-dependent varying rules of radiographic angles of the acetabular cup.

    PubMed

    Zhao, Jing-Xin; Su, Xiu-Yun; Zhao, Zhe; Xiao, Ruo-Xiu; Zhang, Li-Cheng; Tang, Pei-Fu

    2018-02-17

    The aim of this study is to demonstrate the varying rules of radiographic angles following varying three-dimensional (3D) orientations and locations of cup using an accurate mathematical model. A cone model is established to address the quantitative relationship between the opening circle of cup and its ellipse projection on radiograph. The varying rules of two-dimensional (2D) radiographic anteversion (RA) and inclination (RI) angles can be analyzed. When the centre of cup is located above X-ray source, with proper 3D RI/RA angles, 2D RA angle can be equal to its 3D counterpart, and 2D RI angle is usually greater than its 3D counterpart. Except for the original point on hip-centered anterior-posterior radiograph, there is no area on radiograph where both 2D RA and RI angles are equal to their 3D counterparts simultaneously. This study proposes an innovative model for accurately explaining how 2D RA/RI angles of cup are varying following different 3D RA/RI angles and location of cup. The analysis results provide clinicians an intuitive grasp of knowledge about 2D RA/RI angles greater or smaller than their 3D counterparts post-operatively. The established model may allow determining the effects of pelvic rotations on 2D radiographic angles of cup.

  6. Closed Versus Open Supracondylar Fractures of the Humerus in Children: A Comparison of Clinical and Radiographic Presentation and Results.

    PubMed

    Lewine, Eliza; Kim, Jaehon M; Miller, Patricia E; Waters, Peter M; Mahan, Susan T; Snyder, Brian; Hedequist, Daniel; Bae, Donald S

    2018-02-01

    The purpose of this investigation was to compare the presentation and postoperative results of children treated for open and closed, completely displaced type III supracondylar humerus fractures (SCFs). Thirty patients with open and 66 patients with closed, completely displaced type III SCFs were evaluated. Open fractures underwent irrigation and debridement, and all patients were treated by open or closed reduction and pin fixation. Medical records were reviewed to obtain demographic information as well as preoperative and postoperative clinical data regarding mechanism of injury, neurovascular status, associated injuries, postoperative range of motion, infections, and pain. Radiographs were evaluated to quantify displacement, Baumann's angle, humeral capitellar angle, position of the anterior humeral line, and adequacy of reduction. Outcomes were assessed using Flynn criteria. Mean clinical follow-up for the open and closed fracture groups was 8.9 and 5.7 months, respectively. Both groups were similar with respect to age, sex distribution, weight and body mass index, laterality of involvement, and mechanism of injury. At presentation, 35% of closed SCFs and 23% of open SCFs presented with abnormal neurovascular status. There was a higher prevalence of diminished/absent pulses or distal limb ischemia in patients with open injuries (27%) compared with closed fractures (18%). Conversely, severely displaced closed fractures were more commonly associated with nerve injury/palsy at presentation (35%) than those with open fractures (23%). Spontaneous nerve recovery was seen in 87% within 3 to 6 months. Postoperative loss of reduction and malunion were more common in the closed fracture group. However, 84% of patients achieved good-to-excellent results by Flynn criteria, with no appreciable difference based upon open versus closed fractures. With timely wound and fracture treatment, the clinical and radiographic results of children treated for open SCFs is similar to those with closed type III injuries, with little increased risk for infection, malunion, or neurovascular compromise. Level III.

  7. The structures, stratigraphy and evolution of the Gulf of Corinth rift, Greece

    NASA Astrophysics Data System (ADS)

    Taylor, Brian; Weiss, Jonathan R.; Goodliffe, Andrew M.; Sachpazi, Maria; Laigle, Mireille; Hirn, Alfred

    2011-06-01

    A multichannel seismic and bathymetry survey of the central and eastern Gulf of Corinth (GoC), Greece, reveals the offshore fault geometry, seismic stratigraphy and basin evolution of one of Earths most active continental rift systems. Active, right-stepping, en-echelon, north-dipping border faults trend ESE along the southern Gulf margin, significantly overlapping along strike. The basement offsets of three (Akrata-Derveni, Sithas and Xylocastro) are linked. The faults are biplanar to listric: typically intermediate angle (˜35° in the centre and 45-48° in the east) near the surface but decreasing in dip and/or intersecting a low- or shallow-angle (15-20° in the centre and 19-30° in the east) curvi-planar reflector in the basement. Major S-dipping border faults were active along the northern margin of the central Gulf early in the rift history, and remain active in the western Gulf and in the subsidiary Gulf of Lechaio, but unlike the southern border faults, are without major footwall uplift. Much of the eastern rift has a classic half-graben architecture whereas the central rift has a more symmetric w- or u-shape. The narrower and shallower western Gulf that transects the >40-km-thick crust of the Hellenides is associated with a wider distribution of overlapping high-angle normal faults that were formerly active on the Peloponnesus Peninsula. The easternmost sector includes the subsidiary Gulfs of Lechaio and Alkyonides, with major faults and basement structures trending NE, E-W and NW. The basement faults that control the rift architecture formed early in the rift history, with little evidence (other than the Vrachonisida fault along the northern margin) in the marine data for plan view evolution by subsequent fault linkage. Several have maximum offsets near one end. Crestal collapse graben formed where the hanging wall has pulled off the steeper onto the shallower downdip segment of the Derveni Fault. The dominant strikes of the Corinth rift faults gradually rotate from 090-120° in the basement and early rift to 090-100° in the latest rift, reflecting a ˜10° rotation of the opening direction to the 005° presently measured by GPS. The sediments include a (locally >1.5-km-) thick, early-rift section, and a late-rift section (also locally >1.5-km-thick) that we subdivide into three sequences and correlate with seven 100-ka glacio-eustatic cycles. The Gulf depocentre has deepened through time (currently >700 mbsl) as subsidence has outpaced sedimentation. We measure the minimum total horizontal extension across the central and eastern Gulf as varying along strike between 4 and 10 km, and estimate full values of 6-11 km. The rift evolution is strongly influenced by the inherited basement fabric. The regional NNW structural fabric of the Hellenic nappes changes orientation to ESE in the Parnassos terrane, facilitating the focused north-south extension observed offshore there. The basement-penetrating faults lose seismic reflectivity above the 4-14-km-deep seismogenic zone. Multiple generations and dips of normal faults, some cross-cutting, accommodate extension beneath the GoC, including low-angle (15-20°) interfaces in the basement nappes. The thermally cool forearc setting and cross-orogen structures unaccompanied by magmatism make this rift a poor analogue and unlikely precursor for metamorphic core complex formation.

  8. Effects of enamel abrasion, salivary pellicle, and measurement angle on the optical assessment of dental erosion.

    PubMed

    Lussi, Adrian; Bossen, Anke; Höschele, Christoph; Beyeler, Barbara; Megert, Brigitte; Meier, Christoph; Rakhmatullina, Ekaterina

    2012-09-01

    The present study assessed the effects of abrasion, salivary proteins, and measurement angle on the quantification of early dental erosion by the analysis of reflection intensities from enamel. Enamel from 184 caries-free human molars was used for in vitro erosion in citric acid (pH 3.6). Abrasion of the eroded enamel resulted in a 6% to 14% increase in the specular reflection intensity compared to only eroded enamel, and the reflection increase depended on the erosion degree. Nevertheless, monitoring of early erosion by reflection analysis was possible even in the abraded eroded teeth. The presence of the salivary pellicle induced up to 22% higher reflection intensities due to the smoothing of the eroded enamel by the adhered proteins. However, this measurement artifact could be significantly minimized (p<0.05) by removing the pellicle layer with 3% NaOCl solution. Change of the measurement angles from 45 to 60 deg did not improve the sensitivity of the analysis at late erosion stages. The applicability of the method for monitoring the remineralization of eroded enamel remained unclear in a demineralization/remineralization cycling model of early dental erosion in vitro.

  9. Effects of enamel abrasion, salivary pellicle, and measurement angle on the optical assessment of dental erosion

    NASA Astrophysics Data System (ADS)

    Lussi, Adrian; Bossen, Anke; Höschele, Christoph; Beyeler, Barbara; Megert, Brigitte; Meier, Christoph; Rakhmatullina, Ekaterina

    2012-09-01

    The present study assessed the effects of abrasion, salivary proteins, and measurement angle on the quantification of early dental erosion by the analysis of reflection intensities from enamel. Enamel from 184 caries-free human molars was used for in vitro erosion in citric acid (pH 3.6). Abrasion of the eroded enamel resulted in a 6% to 14% increase in the specular reflection intensity compared to only eroded enamel, and the reflection increase depended on the erosion degree. Nevertheless, monitoring of early erosion by reflection analysis was possible even in the abraded eroded teeth. The presence of the salivary pellicle induced up to 22% higher reflection intensities due to the smoothing of the eroded enamel by the adhered proteins. However, this measurement artifact could be significantly minimized (p<0.05) by removing the pellicle layer with 3% NaOCl solution. Change of the measurement angles from 45 to 60 deg did not improve the sensitivity of the analysis at late erosion stages. The applicability of the method for monitoring the remineralization of eroded enamel remained unclear in a demineralization/remineralization cycling model of early dental erosion in vitro.

  10. Impact of preoperative regular physical activity on postoperative course after open abdominal aortic aneurysm surgery.

    PubMed

    Hayashi, Kazuhiro; Hirashiki, Akihiro; Kodama, Akio; Kobayashi, Kiyonori; Yasukawa, Yuto; Shimizu, Miho; Kondo, Takahisa; Komori, Kimihiro; Murohara, Toyoaki

    2016-04-01

    Early ambulation after open abdominal aortic aneurysm (AAA) surgery is assumed to play a key role in preventing postoperative complications and reducing hospital length of stay. However, the factors predicting early ambulation after open AAA surgery have not yet been sufficiently investigated. Here, we investigated which preoperative and intraoperative variables are associated with start time for ambulation in patients after open AAA surgery. A total of 67 consecutive patients undergoing open AAA surgery were included in the study [male, 62 (92 %); mean age, 68 years (range, 47-82 years), mean AAA diameter, 53 mm (range, 28-80 mm)]. Preoperative physical activity was examined by means of 6-min walk distance (6MWD) and a medical interview. Patients were divided into two groups, according to when independence in walking was attained: early group <3 days (n = 36) and late group ≥3 days (n = 31), and the pre-, intra-, and postoperative recovery data were compared. There were no significant differences in patient baseline characteristics or intraoperative data between the two groups. The number of patients engaging in preoperative regular physical activity and 6MWD were significantly greater (p = 0.042 and p = 0.034, respectively) in the early group than in the late group. In addition, time to hospital discharge was significantly shorter in the early group than in the late group (p = 0.031). Binary logistic regression analysis showed that preoperative regular physical activity was the only independent factor for identifying patients in the early group (odds ratio 2.769, 95 % confidence interval 1.024-7.487, p = 0.045). These results suggest that engaging in regular physical activity is an effective predictor of early ambulation after open AAA surgery.

  11. Scanning laser topography and scanning laser polarimetry: comparing both imaging methods at same distances from the optic nerve head.

    PubMed

    Kremmer, Stephan; Keienburg, Marcus; Anastassiou, Gerasimos; Schallenberg, Maurice; Steuhl, Klaus-Peter; Selbach, J Michael

    2012-01-01

    To compare the performance of scanning laser topography (SLT) and scanning laser polarimetry (SLP) on the rim of the optic nerve head and its surrounding area and thereby to evaluate whether these imaging technologies are influenced by other factors beyond the thickness of the retinal nerve fiber layer (RNFL). A total of 154 eyes from 5 different groups were examined: young healthy subjects (YNorm), old healthy subjects (ONorm), patients with normal tension glaucoma (NTG), patients with open-angle glaucoma and early glaucomatous damage (OAGE) and patients with open-angle glaucoma and advanced glaucomatous damage (OAGA). SLT and SLP measurements were taken. Four concentric circles were superimposed on each of the images: the first one measuring at the rim of the optic nerve head (1.0 ONHD), the next measuring at 1.25 optic nerve head diameters (ONHD), at 1.5 ONHD and at 1.75 ONHD. The aligned images were analyzed using GDx/NFA software. Both methods showed peaks of RNFL thickness in the superior and inferior segments of the ONH. The maximum thickness, registered by the SLT device was at the ONH rim where the SLP device tended to measure the lowest values. SLT measurements at the ONH were influenced by other tissues besides the RNFL like blood vessels and glial tissues. SLT and SLP were most strongly correlated at distances of 1.25 and 1.5 ONHD. While both imaging technologies are valuable tools in detecting glaucoma, measurements at the ONH rim should be interpreted critically since both methods might provide misleading results. For the assessment of the retinal nerve fiber layer we would like to recommend for both imaging technologies, SLT and SLP, measurements in 1.25 and 1.5 ONHD distance of the rim of the optic nerve head.

  12. Intraocular Pressure Control after Trabeculectomy, Phacotrabeculectomy and Phacoemulsification in a Hispanic Population.

    PubMed

    L Jung, Jennifer; Isida-Llerandi, Cristina G; Lazcano-Gomez, Gabriel; SooHoo, Jeffrey R; Kahook, Malik Y

    2014-01-01

    To compare the efficacy of different surgical strategies for intraocular pressure (IOP) control in Hispanic glaucoma patients with and without visually significant cataracts. Comparative retrospective consecutive case series. The charts of 153 consecutive patients with primary open angle glaucoma who underwent either trabeculectomy alone (n = 51), phacotrabeculectomy (n = 51), or phacoemulsification alone (n = 51) were reviewed to compare IOP control, the number of glaucoma medications required postoperatively, and the inci dence of surgical complications. Preoperative IOP was 17.5 ± 5.2 mm Hg in the trabe-culectomy group, 15.4 ± 4.5 mm Hg in the phacotrabeculectomy group and 13.9 ± 2.9 mm Hg in the phacoemulsification group (p < 0.001 for all comparisons). Mean IOP reduction from baseline was 4.2 ± 6.9 (24.6%) for the trabeculectomy group, 2.9 ± 5.0 (20.8%) for the phacotrabeculectomy group, and 0.9 ± 3.4 (6.5%) for the phacoemulsification group (p = 0.009). The number of IOP-lowering medications required postoperatively decreased significantly in all three groups (p = 0.001). The rate of early and late postoperative complications was similar between the trabeculectomy and phacotrabeculectomy groups and less for the phacoemulsification group. Trabeculectomy and phacotrabeculectomy are both viable surgical options for managing open angle glau coma. Both resulted in similar rates of success, IOP reduction, decrease in use of IOP-lowering medications and post operative complication rates. Phacoemulsification alone had a lower success rate and greater need for postoperative IOP-lowering medications compared to trabeculectomy alone or phacotrabeculectomy. Phacoemulsification alone may be a reasonable option for patients with visually significant cataract and lower baseline IOP. How to cite this article: Jung JL, Isida-Llerandi CG, Lazcano-Gomez G, SooHoo JR, Kahook MY. Intraocular Pressure Control after Trabeculectomy, Phacotrabeculectomy and Phaco-emulsification in a Hispanic Population. J Curr Glaucoma Pract 2014;8(2):67-74.

  13. Intraocular Pressure Control after Trabeculectomy, Phacotrabeculectomy and Phacoemulsification in a Hispanic Population

    PubMed Central

    L Jung, Jennifer; Isida-Llerandi, Cristina G; Lazcano-Gomez, Gabriel; SooHoo, Jeffrey R

    2014-01-01

    ABSTRACT Purpose: To compare the efficacy of different surgical strategies for intraocular pressure (IOP) control in Hispanic glaucoma patients with and without visually significant cataracts. Design: Comparative retrospective consecutive case series. Methods: The charts of 153 consecutive patients with primary open angle glaucoma who underwent either trabeculectomy alone (n = 51), phacotrabeculectomy (n = 51), or phacoemulsification alone (n = 51) were reviewed to compare IOP control, the number of glaucoma medications required postoperatively, and the inci dence of surgical complications. Results: Preoperative IOP was 17.5 ± 5.2 mm Hg in the trabe-culectomy group, 15.4 ± 4.5 mm Hg in the phacotrabeculectomy group and 13.9 ± 2.9 mm Hg in the phacoemulsification group (p < 0.001 for all comparisons). Mean IOP reduction from baseline was 4.2 ± 6.9 (24.6%) for the trabeculectomy group, 2.9 ± 5.0 (20.8%) for the phacotrabeculectomy group, and 0.9 ± 3.4 (6.5%) for the phacoemulsification group (p = 0.009). The number of IOP-lowering medications required postoperatively decreased significantly in all three groups (p = 0.001). The rate of early and late postoperative complications was similar between the trabeculectomy and phacotrabeculectomy groups and less for the phacoemulsification group. Conclusion: Trabeculectomy and phacotrabeculectomy are both viable surgical options for managing open angle glau coma. Both resulted in similar rates of success, IOP reduction, decrease in use of IOP-lowering medications and post operative complication rates. Phacoemulsification alone had a lower success rate and greater need for postoperative IOP-lowering medications compared to trabeculectomy alone or phacotrabeculectomy. Phacoemulsification alone may be a reasonable option for patients with visually significant cataract and lower baseline IOP. How to cite this article: Jung JL, Isida-Llerandi CG, Lazcano-Gomez G, SooHoo JR, Kahook MY. Intraocular Pressure Control after Trabeculectomy, Phacotrabeculectomy and Phaco-emulsification in a Hispanic Population. J Curr Glaucoma Pract 2014;8(2):67-74. PMID:26997812

  14. Shotgun proteomics reveals specific modulated protein patterns in tears of patients with primary open angle glaucoma naïve to therapy.

    PubMed

    Pieragostino, Damiana; Agnifili, Luca; Fasanella, Vincenzo; D'Aguanno, Simona; Mastropasqua, Rodolfo; Di Ilio, Carmine; Sacchetta, Paolo; Urbani, Andrea; Del Boccio, Piero

    2013-06-01

    Primary open angle glaucoma (POAG) is one of the main causes of irreversible blindness worldwide. The pathogenesis of POAG is still unclear. Alteration and sclerosis of trabecular meshwork with changes in aqueous humor molecular composition seem to play the key role. Increased intraocular pressure is widely known to be the main risk factor for the onset and progression of the disease. Unfortunately, the early diagnosis of POAG still remains the main challenge. In order to provide insight into the patho-physiology of glaucoma, here we report a shotgun proteomics approach to tears of patients with POAG naïve to therapy. Our proteomics results showed 27 differential tear proteins in POAG vs. CTRL comparison (25 up regulated proteins in the POAG group and two unique proteins in the CTRL group), 16 of which were associated with inflammatory response, free radical scavenging, cell-to-cell signaling and interaction. Overall the protein modulation shown in POAG tears proves the involvement of biochemical networks linked to inflammation. Among all regulated proteins, a sub-group of 12 up-regulated proteins in naïve POAG patients were found to be down-regulated in medically controlled POAG patients treated with prostanoid analogues (PGA), as reported in our previous work (i.e., lipocalin-1, lysozyme C, lactotransferrin, proline-rich-protein 4, prolactin-inducible protein, zinc-alpha-2-glycoprotein, polymeric immunoglobulin receptor, cystatin S, Ig kappa chain C region, Ig alpha-2 chain C region, immunoglobulin J chain, Ig alpha-1 chain C region). In summary, our findings indicate that the POAG tears protein expression is a mixture of increased inflammatory proteins that could be potential biomarkers of the disease, and their regulation may be involved in the mechanism by which PGA are able to decrease the intraocular pressure in glaucoma patients.

  15. Comparison of Risk Factor Profiles for Primary Open-Angle Glaucoma Subtypes Defined by Pattern of Visual Field Loss: A Prospective Study.

    PubMed

    Kang, Jae H; Loomis, Stephanie J; Rosner, Bernard A; Wiggs, Janey L; Pasquale, Louis R

    2015-04-01

    We explored whether risk factor associations differed by primary open-angle glaucoma (POAG) subtypes defined by visual field (VF) loss pattern (i.e., paracentral or peripheral). We included 77,157 women in the Nurses' Health Study (NHS) and 42,773 men in the Health Professionals Follow-up Study (HPFS 1986-2010), and incident medical record confirmed cases of paracentral (n = 440) and peripheral (n = 865) POAG subtypes. We evaluated African heritage, glaucoma family history, body mass index (BMI), mean arterial blood pressure, diabetes mellitus, physical activity, smoking, caffeine intake, and alcohol intake. We used competing risk Cox regression analyses modeling age as the metameter and stratified by age, cohort, and event type. We sequentially identified factors with the least significant differences in associations with POAG subtypes ("stepwise down" approach with P for heterogeneity [P-het] < 0.10 as threshold). Body mass index was more inversely associated with the POAG paracentral VF loss subtype than the peripheral VF loss subtype (per 10 kg/m2; hazard ratio [HR] = 0.67 [95% confidence interval (CI): 0.52, 0.86] versus HR = 0.93 [95% CI: 0.78, 1.10]; P-het = 0.03) as was smoking (per 10 pack-years; HR = 0.92 [95% CI: 0.87, 0.98] versus HR = 0.98 [95% CI: 0.94, 1.01]; P-het = 0.09). These findings were robust in sensitivity analyses using a "stepwise up" approach (identify factors that showed the most significant differences). Nonheterogeneous (P-het > 0.10) adverse associations with both POAG subtypes were observed with glaucoma family history, diabetes, African heritage, greater caffeine intake, and higher mean arterial pressure. These data indicate that POAG with early paracentral VF loss has distinct as well as common determinants compared with POAG with peripheral VF loss.

  16. The spectrum of glaucoma presentation at Menelik II Hospital, Addis Ababa.

    PubMed

    Giorgis, Abeba T; Mulugeta, Abiye; Aga, Assegid; Deyassa, Neggusie

    2012-07-01

    Glaucoma is a major cause of blindness in Africa. However, many do not know if they have the disease until late. The aim of this study was to describe the type and severity of glaucoma at presentation A hospital based prospective review of 602 glaucoma patients was conducted over 18 month period ending in 2009. A special registry captured Socio demographic and clinical data at the glaucoma clinic of Menelik II Hospital in Addis Ababa. The vertical cup disc ratio (CDR) of the optic nerve head provided the bases to stage, the severity of glaucoma. Large portion of the total reviewed patients were men, 401 (66.6%) or above the age of 40 years, 484 (80.4%). The mean intraocular pressure was 28.5 and 30.6 in the right and left eye in mmHg. The leading subtypes of glaucoma, accounting 64.3% (n = 387), were Primary Open Angle Glaucoma, 227 (37.7%) and Pseudo exfoliation glaucoma, 160 (26.6%). At presentation, 260 (44%) and 109 (18%)) were unilaterally and bilaterally blind (vision < 3/60) respectively. Bilateral glaucoma was found in 464 (77%) and 366 (61%) presented with advanced stage (CDR > or = 9.0). Cases with advanced stage were likely to present with blindness [Odds Ratio (OR) -6.2 95% CI (3-8-10.1) and 6.9 95% CI (4.2-11.3)] or high Intraocular pressure >30mmHg [OR=3.4, 95% CI (2.2 -5.2) and 2.8, 95% CI (1.4-3.4)] in the respective right and left eyes. The stage, had no statistically significant association with age, sex, residence or type of glaucoma (Chi2 test, p > 0.05). A large proportion of patients still arrive at glaucoma clinic with a very late stage of open angle glaucoma. Intervention strategies are requiredfor early detection and treatment of glaucoma in Ethiopia.

  17. Trabeculotomy combined with phacoemulsification and implantation of an intraocular lens for the treatment of primary open-angle glaucoma and coexisting cataract.

    PubMed

    Tanihara, H; Honjo, M; Inatani, M; Honda, Y; Ogino, N; Ueno, S; Negi, A; Ichioka, H; Mizoguchi, T; Matsumura, M; Nagata, M

    1997-10-01

    The authors previously reported the usefulness of trabeculotomy ab externo for the treatment of primary open-angle glaucoma in adult patients. In an attempt to elucidate the long-term risk-to-benefit ratio of this surgical modality in combination with cataract surgery, the authors conducted a retrospective study of the surgical effects and complications of a triple procedure: phacoemulsification, implantation (of an intraocular lens), and trabeculotomy (PIT). The authors conducted a retrospective study of patients treated with PIT at multiple hospitals. Intraocular pressure (IOP) and visual function data were obtained from patients after PIT as an initial surgical treatment in cases where antiglaucoma medications failed to resolve uncontrolled IOP (higher than 21 mm Hg). Included in this study were 96 eyes of 64 patients with primary open-angle glaucoma and coexisting cataract. The mean follow-up period was 22.6 +/- 14.7 months (range 3-56 months). In 94 (98%) of the 96 eyes, the IOP was well controlled, having achieved a level of 21 mm Hg or lower at the final examinations. The mean preoperative IOP of the 33 eyes that underwent the triple procedure using a single flap method (PIT-I) was 24.3 +/- 3.9 mm Hg, with an average of 2.1 +/- 1.1 medications. At the final examinations, the mean IOP had dropped to 16.0 +/- 1.2 mm Hg, with an average of 1.2 +/- 1.2 medications. The mean preoperative IOP of the 63 eyes that underwent the triple procedure using a double flap method (PIT-II) was 26.2 +/- 6.2 mm Hg, with an average of 1.9 +/- 1.2 medications. At the final examination, the mean IOP for this group was 15.6 +/- 2.9 mm Hg, with an average of 1.0 +/- 0.9 medications. The long-term results from this multicenter study showed that the triple procedure, PIT, can be useful and effective as an initial surgical treatment for open-angle glaucoma in glaucoma patients with coexisting cataract.

  18. Verification of the Robin and Graham classification system of hip disease in cerebral palsy using three-dimensional computed tomography.

    PubMed

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Akiyama, Keisuke; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2011-12-01

    We evaluated the validity of the Robin and Graham classification system of hip disease in cerebral palsy (CP) using three-dimensional computed tomography in young people with CP. A total of 91 hips in 91 consecutive children with bilateral spastic CP (57 males, 34 females; nine classified at Gross Motor Function Classification System level II, 42 at level III, 32 at level IV, and eight at level V; mean age 5 y 2 mo, SD 11 mo; range 2-6 y) were investigated retrospectively using anteroposterior plain radiographs and three-dimensional computed tomography (3D-CT) of the hip. The migration percentage was calculated on plain radiographs and all participants were classified into four groups according to migration percentage: grade II, migration percentage ≥ 10% but ≤ 15%, (four hips), grade III, migration percentage >15% but ≤ 30%, (20 hips); grade IV, migration percentage >30% but <100%, (63 hips); and grade V, migration percentage ≥ 100%, (four hips). The lateral opening angle and the sagittal inclination angle of the acetabulum, the neck-shaft angle, and the femoral anteversion of the femur were measured on 3D-CT. The three-dimensional quantitative evaluation indicated that there were significant differences in the lateral opening angle and the neck-shaft angle between the four groups (Kruskal-Wallis test, p ≤ 0.001). This three-dimensional evaluation supports the validation of the Robin and Graham classification system for hip disease in 2- to 7-year-olds with CP. © The Authors. Developmental Medicine & Child Neurology © 2011 Mac Keith Press.

  19. Discovery of the Kinematic Alignment of Early-type Galaxies in the Virgo Cluster

    NASA Astrophysics Data System (ADS)

    Kim, Suk; Jeong, Hyunjin; Lee, Jaehyun; Lee, Youngdae; Joo, Seok-Joo; Kim, Hak-Sub; Rey, Soo-Chang

    2018-06-01

    Using the kinematic position angles (PAkin), an accurate indicator for the spin axis of a galaxy, obtained from the ATLAS3D integral-field-unit (IFU) spectroscopic data, we discovered that 57 Virgo early-type galaxies tend to prefer the specific PAkin values of 20° and 100°, suggesting that they are kinematically aligned with each other. These kinematic alignment angles are further associated with the directions of the two distinct axes of the Virgo cluster extending east–west and north–south, strongly suggesting that the two distinct axes are the filamentary structures within the cluster as a trace of infall patterns of galaxies. Given that the spin axis of a massive early-type galaxy does not change easily even in clusters from the hydrodynamic simulations, Virgo early-type galaxies are likely to fall into the cluster along the filamentary structures while maintaining their angular momentum. This implies that many early-type galaxies in clusters are formed in filaments via major mergers before subsequently falling into the cluster. Investigating the kinematic alignment in other clusters will allow us to understand the formation of galaxy clusters and early-type galaxies.

  20. Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle.

    PubMed

    Sakata, Lisandro M; Lavanya, Raghavan; Friedman, David S; Aung, Han T; Gao, Hong; Kumar, Rajesh S; Foster, Paul J; Aung, Tin

    2008-05-01

    To compare the performance of gonioscopy and anterior segment (AS) optical coherence tomography (OCT) in detecting angle closure in the different quadrants of the anterior chamber angle (ACA). Cross-sectional observational study. Five hundred two consecutive subjects more than 50 years of age with no previous ophthalmic problems recruited from a community clinic in Singapore. All subjects underwent gonioscopy and AS OCT imaging in the dark. Using gonioscopy, the ACA was graded using the Scheie system by a single examiner masked to AS OCT findings. The ACA in a particular quadrant was classified as closed if the posterior trabecular meshwork could not be seen on gonioscopy. A closed ACA on AS OCT imaging was defined by the presence of any contact between the iris and angle wall anterior to the scleral spur. After excluding eyes with poor image quality, a total of 423 right eyes were included in the analysis. A closed angle in at least 1 quadrant was observed in 59% of the eyes by AS OCT and in 33% of the eyes by gonioscopy (P<0.001), with fair agreement between the two methods (kappa = 0.40). The frequency of closed angles by AS OCT and gonioscopy were 48% versus 29% superiorly, 43% versus 22% inferiorly, 18% versus 14% nasally, and 12% versus 20% temporally, respectively. Of the 119 of 1692 quadrants that were closed on gonioscopy but open on AS OCT, a steep iris profile was present in 61 (51%) of 119 quadrants on AS OCT, and of the 276 of 1692 quadrants that were open on gonioscopy but closed on AS OCT, 196 (71%) of 276 quadrants showed short iridoangle contact on AS OCT. The highest rates of closed angles on gonioscopy and AS OCT images were observed in the superior quadrant. Anterior segment OCT tended to detect more closed ACAs than gonioscopy, particularly in the superior and inferior quadrants. Variations in the iris profile and level of iridoangle contact also may explain some of the differences seen between gonioscopy and AS OCT.

  1. Enhancing Student Services at Lorain County Community College: Early Results from the Opening Doors Demonstration in Ohio

    ERIC Educational Resources Information Center

    Scrivener, Susan; Au, Jenny

    2007-01-01

    In 2003, MDRC and a consortium of funders launched the Opening Doors demonstration to test reforms in six community colleges aimed at helping students stay in school and earn credentials. This report presents early results from the Opening Doors program at Lorain County Community College in Elyria, Ohio. The program provided intensive advising and…

  2. EMIIM Wetting Properties & Their Effect on Electrospray Thruster Design

    DTIC Science & Technology

    2012-03-01

    tension and contact or “wetting" angle formed when a liquid droplet comes in contact with a solid surface. Ideally this angle is a function of the...3 3 Picture of a Taylor cone formed at AFRL, note bubbles present. . . . . . . 3 4 Titanium electrode grids in use at AFRL...cone formed using an internally wetted emitter and the ionic liquid BMI-BG4 is shown in Figure 3.[7] Emitters are precisely aligned with openings

  3. Evaluation of a New Scoring System for Retinal Nerve Fiber Layer Photography Using HRA1 in 964 Eyes

    PubMed Central

    Hong, Samin; Moon, Jong Wook; Ha, Seung Joo; Kim, Chan Yun; Seong, Gong Je

    2007-01-01

    Purpose To evaluate retinal nerve fiber layer (RNFL) defect by a new scoring system for RNFL photography using the Heidelberg Retina Angiograph 1 (HRA1). Methods This retrospective study included 128 healthy eyes and 836 primary open-angle glaucoma eyes. The RNFL photography using HRA1 was interpreted using a new scoring system, and correlated with visual field indices of standard automated perimetry (SAP). Using the presence of RNFL defect, darkness, width, and location, we established the new scoring system of RNFL photos. Results The mean RNFL defect score I in the early, moderate, severe, and control groups were 7.3, 9.2, 10.4, and 3.6, respectively. The mean RNFL defect score II in the early, moderate, severe, and control groups were 14.5, 28.5, 43.4, and 3.4, respectively. Correlations between the RNFL defect score II and the mean deviation of SAP was the strongest of the various combinations (r=-0.675, P<.001). Conclusions Using a new scoring system, we propose a method for semi-quantitative interpretation of RNFL photographs. This scoring system may be helpful to distinguish between normal and glaucomatous eyes, and the score is associated with the severity of visual field loss. PMID:18063886

  4. Evaluation of the optimal visceral branch configuration in open thoracoabdominal aortic repair by computed tomography.

    PubMed

    Kamohara, Keiji; Furukawa, Kojiro; Itoh, Manabu; Morokuma, Hiroyuki; Tanaka, Hideya; Hayashi, Nagi; Morita, Shigeki

    2015-01-01

    In thoracoabdominal aneurysm (TAAA) repair, our technical modification of visceral reconstruction using longer cut pre-sewn side branches has provided good surgical outcomes. Here, we assessed the long-term durability and patency of revascularized branches using computed tomography (CT) to confirm the validity of our approach. Early and late CT evaluations were performed in 11 TAAA patients (males: 5; mean age: 60.6 years) using the Coselli graft to evaluate the position of main graft and the diverging pattern and patency of side branches. Seven of 11 were sutured in an extra-anatomical fashion using longer cut side branches. In Anatomical (n = 4) and Extra-anatomical (n = 7) groups, the early patency of side branches was not significantly different. Although the late patency of right renal artery (RA) was 100% in both groups, the one of left RA was 60% in Extra-anatomical, while 100% in Anatomical. Furthermore, the main graft in Extra-anatomical was significantly posterior and leftward to the spine with left RA side branch diverging at an acute angle. When a pre-sewn branched graft designed for TAAA is used, the graft should be sutured in a fashion similar to normal patient anatomy to minimize the possibility of kinking of RA side branch for the patency.

  5. 21 CFR 872.3730 - Pantograph.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... and, as the patient's mouth opens, the pen records on graph paper the angle between the upper and the lower jaw. (b) Classification. Class I (general controls). The device is exempt from the premarket...

  6. Glaucoma, Open-Angle

    MedlinePlus

    ... is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye ... Media Policies and Other Important Links NEI Employee Emergency Information NEI Intranet (Employees Only) *PDF files require ...

  7. Glaucoma in Asian Populations

    MedlinePlus

    ... in their Asian counterparts. Normal Tension Glaucoma affects Japanese Japanese populations, however, have a substantially higher incidence of ... factor for open angle glaucoma). In fact, a Japanese study found NTG accounted for 92 percent of ...

  8. Comparison of robotic-assisted and conventional manual implantation of a primary total knee arthroplasty.

    PubMed

    Park, Sang Eun; Lee, Chun Taek

    2007-10-01

    This study was aimed to compare robotic-assisted implantation of a total knee arthroplasty with conventional manual implantation. We controlled, randomized, and reviewed 72 patients for total knee arthroplasty assigned to undergo either conventional manual implantation (excluding navigation-assisted implantation cases) of a Zimmer LPS prosthesis (Zimmer, Warsaw, Ind) (30 patients: group 1) or robotic-assisted implantation of such a prosthesis (32 patients: group 2). The femoral flexion angle (gamma angle) and tibial angle (delta angle) in the lateral x-ray of group 1 were 4.19 +/- 3.28 degrees and 89.7 +/- 1.7 degrees, and those of group 2 were 0.17 +/- 0.65 degrees and 85.5 +/- 0.92 degrees. The major complications were from improper small skin incision during a constraint attempt of minimally invasive surgery and during bulk fixation frame pins insertion. Robotic-assisted technology had definite advantages in terms of preoperative planning, accuracy of the intraoperative procedure, and postoperative follow-up, especially in the femoral flexion angle (gamma angle) and tibial flexion angle (delta angle) in the lateral x-ray, and in the femoral flexion angle (alpha angle) in the anteroposterior x-ray. But a disadvantage was the high complication rate in early stage.

  9. Gyre formation within embayments of a large lake (Lake Geneva, Switzerland)

    NASA Astrophysics Data System (ADS)

    Razmi, A.; Barry, D.; Bouffard, D.; Le Dantec, N.; Lemmin, U.; Wuest, A.

    2013-12-01

    Numerical simulations were carried out to examine gyre formation within open, wide lacustrine embayments. The present study was motivated by observed differences in gyre formation within two open and wide embayments (located at Vidy and Morges in Lake Geneva, Switzerland). These two embayments are located within about 3 km of each other on the northern shore of Lake Geneva, and are subjected to similar pelagic currents. Vidy is deeper and has a greater aspect ratio than Morges. The flow field in the embayments was modeled using a previously validated 3D hydrodynamic model (Delft3D-FLOW). The model solved the Reynolds-Averaged Navier-Stokes equations, combined with a k-ɛ turbulence closure in σ (lakebed-following) coordinates. Our study focused on the influence of the embayment geometry on the (uniform) longshore (pelagic) current, specifically the occurrence and magnitude of circulation within the embayment. We built a set of numerical experiments using synthetic embayments, and systematically examined embayment geometry, thereby capturing the differences between the Vidy and Morges embayments. The numerical experiments considered single rectilinear embayments with different aspect ratios (i.e., 1-6), depth, shore-parallel flow rates, and embayment corner angle between 0°-50°. The circulation magnitude changes abruptly for an angle of about 40°. Embayments with angles greater than 40° have much greater circulation then those with lesser angles, other factors remaining the same. Of the factors considered (i.e., aspect ratio, offshore current velocity, corner angle, bottom slope, and viscosity), bottom slope and the viscosity have almost no impact on embayment circulation. For uniform offshore current patterns, gyres form in embayments with large aspect ratios (up to ~3). For the Vidy and Morges embayments, the results showed that gyre formation is more likely in Morges due to its smaller aspect ratio, a finding that is supported by field data gathered in drifter studies. For example, simultaneous drifter releases in 2011 showed parallel-to-shore currents in the Vidy embayment and a gyre in Morges. KEYWORDS: Hydrodynamics; Open Embayment; Flow Separation; Gyre; Topography; Lake Geneva.

  10. Apparatus For Laminating Segmented Core For Electric Machine

    DOEpatents

    Lawrence, Robert Anthony; Stabel, Gerald R

    2003-06-17

    A segmented core for an electric machine includes segments stamped from coated electric steel. The segments each have a first end, a second end, and winding openings. A predetermined number of segments are placed end-to-end to form layers. The layers are stacked such that each of the layers is staggered from adjacent layers by a predetermined rotation angle. The winding openings of each of the layers are in vertical alignment with the winding openings of the adjacent layers. The stack of layers is secured to form the segmented core.

  11. Phase III Early Restoration Meeting - Galveston, TX | NOAA Gulf Spill

    Science.gov Websites

    Areas Alabama Florida Louisiana Mississippi Texas Region-wide Open Ocean Data Media & News planning for Phase III and future early restoration plans. Open House: 6:00pm Public Meeting: 6:30pm

  12. Phase III Early Restoration Meeting - Port Arthur, TX | NOAA Gulf Spill

    Science.gov Websites

    Areas Alabama Florida Louisiana Mississippi Texas Region-wide Open Ocean Data Media & News planning for Phase III and future early restoration plans. Open House: 6:00pm Public Meeting: 6:30pm

  13. Phase III Early Restoration Meeting - Panama City, FL | NOAA Gulf Spill

    Science.gov Websites

    Areas Alabama Florida Louisiana Mississippi Texas Region-wide Open Ocean Data Media & News planning for Phase III and future early restoration plans. Open House: 6:00pm Public Meeting: 6:30pm

  14. Angle imaging: Advances and challenges

    PubMed Central

    Quek, Desmond T L; Nongpiur, Monisha E; Perera, Shamira A; Aung, Tin

    2011-01-01

    Primary angle closure glaucoma (PACG) is a major form of glaucoma in large populous countries in East and South Asia. The high visual morbidity from PACG is related to the destructive nature of the asymptomatic form of the disease. Early detection of anatomically narrow angles is important and the subsequent prevention of visual loss from PACG depends on an accurate assessment of the anterior chamber angle (ACA). This review paper discusses the advantages and limitations of newer ACA imaging technologies, namely ultrasound biomicroscopy, Scheimpflug photography, anterior segment optical coherence tomography and EyeCam, highlighting the current clinical evidence comparing these devices with each other and with clinical dynamic indentation gonioscopy, the current reference standard. PMID:21150037

  15. Mapping a gene for adult-onset primary open-angle glaucoma to chromosome 3q

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wirtz, M.K.; Samples, J.R.; Kramer, P.L.

    1997-02-01

    Glaucoma is the third-leading cause of blindness in the world, affecting >13.5 million people. Adult-on-set primary open-angle glaucoma (POAG) is the most common form of glaucoma in the United States. We present a family in which adult-onset POAG is inherited as an autosomal dominant trait. Twelve affected family members were identified from 44 at-risk individuals. The disease-causing gene was mapped to chromosome 3q21-24, with analysis of recombinant haplotypes suggesting a total inclusion region of 11.1 cM between markers D3S3637 and D3S1744. This is the first report of mapping of an adult-onset POAG gene to chromosome 3q, gene symbol GLC1C. 57more » refs., 3 figs., 3 tabs.« less

  16. A Relationship Between Constraint and the Critical Crack Tip Opening Angle

    NASA Technical Reports Server (NTRS)

    Johnston, William M.; James, Mark A.

    2009-01-01

    Of the various approaches used to model and predict fracture, the Crack Tip Opening Angle (CTOA) fracture criterion has been successfully used for a wide range of two-dimensional thin-sheet and thin plate applications. As thicker structure is considered, modeling the full three-dimensional fracture process will become essential. This paper investigates relationships between the local CTOA evaluated along a three-dimensional crack front and the corresponding local constraint. Previously reported tunneling crack front shapes were measured during fracture by pausing each test and fatigue cycling the specimens to mark the crack surface. Finite element analyses were run to model the tunneling shape during fracture, with the analysis loading conditions duplicating those tests. The results show an inverse relationship between the critical fracture value and constraint which is valid both before maximum load and after maximum load.

  17. Comparison of optical coherence tomography findings and visual field changes in patients with primary open-angle glaucoma and amyotrophic lateral sclerosis.

    PubMed

    Liu, Ziyuan; Wang, Hongli; Fan, Dongsheng; Wang, Wei

    2018-02-01

    Recent studies revealing genetic connection of primary open angle glaucoma (POAG) and amyotrophic lateral sclerosis (ALS) have received particular attention. Exploring the evidence for common pathogenesis of these two progressive neurological disorders may assist in understanding the mechanism and searching for new treatment. Retinal nerve fiber layer (RNFL) defect and corresponding visual field (VF) impairment are well known neuropathy signs in glaucoma. In our study, thickness of certain retinal layer in ALS patients was analyzed to detect ganglion cell's soma and axon, and for first time visual field was examined for ALS. The correlation of retinal involvement and ALS progression were also investigated. The results were compared with those of POAG. The study may provide new knowledge for these two neurodegenerative diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Blindness following bleb-related infection in open angle glaucoma.

    PubMed

    Yamada, Hiroki; Sawada, Akira; Kuwayama, Yasuaki; Yamamoto, Tetsuya

    2014-11-01

    To estimate the risk of blindness following bleb-related infection after trabeculectomy with mitomycin C in open angle glaucoma, utilizing data obtained from two prospective multicenter studies. The incidence of bleb-related infection in open angle glaucoma after the first or second glaucoma surgery was calculated using a Kaplan-Meier analysis and data from the Collaborative Bleb-related Infection Incidence and Treatment Study (CBIITS). The rate of blindness following bleb-related infection was calculated using data from the Japan Glaucoma Society Survey of Bleb-related Infection (JGSSBI). Finally, the rate of blindness following bleb-related infection after filtering surgery was estimated based on the above two data sets. Blindness was defined as an eye with a visual acuity of 0.04 or less. The incidences of development of bleb-related infection at 5 years were 2.6 ± 0.7 % (calculated cumulative incidence ± standard error) for all infections and 0.9 ± 0.4 % for endophthalmitis in all cases in the CBIITS data. The rates of blindness in the JGSSBI data were 14 % for the total cases with bleb-related infection and 30 % for the endophthalmitis subgroup. The rate of blindness developing within 5 years following trabeculectomy was estimated to be approximately 0.24-0.36 %. The rate of blindness following bleb-related infection within 5 years after trabeculectomy is considerable and thus careful consideration must be given to the indication for trabeculectomy and the selection of surgical techniques.

  19. Effect of open hole on tensile failure properties of 2D triaxial braided textile composites and tape equivalents

    NASA Technical Reports Server (NTRS)

    Norman, Timothy L.; Anglin, Colin; Gaskin, David; Patrick, Mike

    1995-01-01

    The unnotched and notched (open hole) tensile strength and failure mechanisms of two-dimensional (2D) triaxial braided composites were examined. The effect of notch size and notch position were investigated. Damage initiation and propagation in notched and unnotched coupons were also examined. Theory developed to predict the normal stress distribution near an open hole and failure for tape laminated composites was evaluated for its applicability to triaxial braided textile composite materials. Four fiber architectures were considered with different combinations of braid angle, longitudinal and braider yam size, and percentage of longitudinal yarns. Tape laminates equivalent to textile composites were also constructed for comparison. Unnotched tape equivalents were stronger than braided textiles but exhibited greater notch sensitivity. Notched textiles and tape equivalents have roughly the same strength at large notch sizes. Two common damage mechanisms were found: braider yams cracking and near notch longitudinal yarn splitting. Cracking was found to initiate in braider yarns in unnotched and notched coupons, and propagate in the direction of the braider yarns until failure. Longitudinal yarn splitting occurred in three of four architectures that were longitudinally fiber dominated. Damage initiation stress decreased with increasing braid angle. No significant differences in prediction of near notch stress between measured and predicted stress were weak for textiles with large braid angle. Notch strength could not be predicted using existing anisotropic theory for braided textiles due to their insensitivity to notch.

  20. Intersecting flavor branes

    NASA Astrophysics Data System (ADS)

    Pomoni, Elli; Rastelli, Leonardo

    2012-10-01

    We consider an instance of the AdS/CFT duality where the bulk theory contains an open string tachyon, and study the instability from the viewpoint of the boundary field theory. We focus on the specific example of the AdS5 × S 5 background with two probe D7 branes intersecting at general angles. For generic angles supersymmetry is completely broken and there is an open string tachyon between the branes. The field theory action for this system is obtained by coupling to {N}=4 super Yang-Mills two {N}=2 hyper multiplets in the fundamental representation of the SU( N) gauge group, but with different choices of embedding of the two {N}=2 subalgebras into {N}=4 . On the field theory side we find a one-loop Coleman-Weinberg instability in the effective potential for the fundamental scalars. We identify a mesonic operator as the dual of the open string tachyon. By AdS/CFT, we predict the tachyon mass for small 't Hooft coupling (large bulk curvature) and confirm that it violates the AdS stability bound.

  1. A new technique for quantifying symmetry and opening angles in quartz c-axis pole figures: Implications for interpreting the kinematic and thermal properties of rocks

    NASA Astrophysics Data System (ADS)

    Hunter, N. J. R.; Weinberg, R. F.; Wilson, C. J. L.; Law, R. D.

    2018-07-01

    Variations in flow kinematics influence the type of crystallographic preferred orientations (CPOs) in plastically deformed quartz, yet we currently lack a robust means of quantifying the diagnostic symmetries that develop in the c-axis (0001) pole figure. In this contribution, we demonstrate how the symmetry of common c-axis topologies may be quantified by analysing the intensity distribution across a line transect of the pole figure margin. A symmetry value (S) measures the relative difference in intensities between marginal girdle maxima in the pole figure, and thus the degree to which the pole figure defines orthorhombic or monoclinic end member symmetries. This provides a semi-quantitative depiction of whether the rocks underwent coaxial or non-coaxial flow, respectively, and may subsequently be used to quantify other topological properties, such as the opening angle of girdle maxima. The open source Matlab® toolbox MTEX is used to quantify pole figure symmetries in quartzite samples from the Main Central Thrust (NW Himalaya) and the Moine Thrust (NW Scotland).

  2. Broadband and polarization reflectors in the lookdown, Selene vomer

    PubMed Central

    Zhao, Shulei; Brady, Parrish Clawson; Gao, Meng; Etheredge, Robert Ian; Kattawar, George W.; Cummings, Molly E.

    2015-01-01

    Predator evasion in the open ocean is difficult because there are no objects to hide behind. The silvery surface of fish plays an important role in open water camouflage. Various models have been proposed to account for the broadband reflectance by the fish skin that involve one-dimensional variations in the arrangement of guanine crystal reflectors, yet the three-dimensional organization of these guanine platelets have not been well characterized. Here, we report the three-dimensional organization and the optical properties of integumentary guanine platelets in a silvery marine fish, the lookdown (Selene vomer). Our structural analysis and computational modelling show that stacks of guanine platelets with random yaw angles in the fish skin produce broadband reflectance via colour mixing. Optical axes of the guanine platelets and the collagen layer are aligned closely and provide bulk birefringence properties that influence the polarization reflectance by the skin. These data demonstrate how the lookdown preserves or alters polarization states at different incident polarization angles. These optical properties resulted from the organization of these guanine platelets and the collagen layer may have implications for open ocean camouflage in varying light fields. PMID:25673301

  3. Visualization of the 3-D topography of the optic nerve head through a passive stereo vision model

    NASA Astrophysics Data System (ADS)

    Ramirez, Juan M.; Mitra, Sunanda; Morales, Jose

    1999-01-01

    This paper describes a system for surface recovery and visualization of the 3D topography of the optic nerve head, as support of early diagnosis and follow up to glaucoma. In stereo vision, depth information is obtained from triangulation of corresponding points in a pair of stereo images. In this paper, the use of the cepstrum transformation as a disparity measurement technique between corresponding windows of different block sizes is described. This measurement process is embedded within a coarse-to-fine depth-from-stereo algorithm, providing an initial range map with the depth information encoded as gray levels. These sparse depth data are processed through a cubic B-spline interpolation technique in order to obtain a smoother representation. This methodology is being especially refined to be used with medical images for clinical evaluation of some eye diseases such as open angle glaucoma, and is currently under testing for clinical evaluation and analysis of reproducibility and accuracy.

  4. The 3D-architecture of individual free silver nanoparticles captured by X-ray scattering

    PubMed Central

    Barke, Ingo; Hartmann, Hannes; Rupp, Daniela; Flückiger, Leonie; Sauppe, Mario; Adolph, Marcus; Schorb, Sebastian; Bostedt, Christoph; Treusch, Rolf; Peltz, Christian; Bartling, Stephan; Fennel, Thomas; Meiwes-Broer, Karl-Heinz; Möller, Thomas

    2015-01-01

    The diversity of nanoparticle shapes generated by condensation from gaseous matter reflects the fundamental competition between thermodynamic equilibration and the persistence of metastable configurations during growth. In the kinetically limited regime, intermediate geometries that are favoured only in early formation stages can be imprinted in the finally observed ensemble of differently structured specimens. Here we demonstrate that single-shot wide-angle scattering of femtosecond soft X-ray free-electron laser pulses allows three-dimensional characterization of the resulting metastable nanoparticle structures. For individual free silver particles, which can be considered frozen in space for the duration of photon exposure, both shape and orientation are uncovered from measured scattering images. We identify regular shapes, including species with fivefold symmetry and surprisingly large aspect ratio up to particle radii of the order of 100 nm. Our approach includes scattering effects beyond Born’s approximation and is remarkably efficient—opening up new routes in ultrafast nanophysics and free-electron laser science. PMID:25650004

  5. The 3D-architecture of individual free silver nanoparticles captured by X-ray scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barke, Ingo; Hartmann, Hannes; Rupp, Daniela

    The diversity of nanoparticle shapes generated by condensation from gaseous matter reflects the fundamental competition between thermodynamic equilibration and the persistence of metastable configurations during growth. In the kinetically limited regime, intermediate geometries that are favoured only in early formation stages can be imprinted in the finally observed ensemble of differently structured specimens. Here we demonstrate that single-shot wide-angle scattering of femtosecond soft X-ray free-electron laser pulses allows three-dimensional characterization of the resulting metastable nanoparticle structures. For individual free silver particles, which can be considered frozen in space for the duration of photon exposure, both shape and orientation are uncoveredmore » from measured scattering images. We identify regular shapes, including species with fivefold symmetry and surprisingly large aspect ratio up to particle radii of the order of 100 nm. Our approach includes scattering effects beyond Born’s approximation and is remarkably efficient—opening up new routes in ultrafast nanophysics and free-electron laser science« less

  6. NMR Studies of Cartilage Dynamics, Diffusion, Degradation

    NASA Astrophysics Data System (ADS)

    Huster, Daniel; Schiller, Jurgen; Naji, Lama; Kaufmann Jorn; Arnold, Klaus

    An increasing number of people is suffering from rheumatic diseases, and, therefore, methods of early diagnosis of joint degeneration are urgently required. For their establishment, however, an improved knowledge about the molecular organisation of cartilage would be helpful. Cartilage consists of three main components: Water, collagen and chondroitin sulfate (CS) that is (together with further polysaccharides and proteins) a major constituent of the proteoglycans of cartilage. 1H and 13C MAS (magic-angle spinning) NMR (nuclear magnetic resonance) opened new perspectives for the study of the macromolecular components in cartilage. We have primarily studied the mobilities of CS and collagen in bovine nasal and pig articular cartilage (that differ significantly in their collagen/polysaccharide content) by measuring 13C NMR relaxation times as well as the corresponding 13C CP (cross polarisation) MAS NMR spectra. These data clearly indicate that the mobility of cartilage macromolecules is broadly distributed from almost completely rigid (collagen) to highly mobile (polysaccharides), which lends cartilage its mechanical strength and shock-absorbing properties.

  7. Buffet Load Alleviation

    NASA Technical Reports Server (NTRS)

    Ryall, T. G.; Moses, R. W.; Hopkins, M. A.; Henderson, D.; Zimcik, D. G.; Nitzsche, F.

    2004-01-01

    High performance aircraft are, by their very nature, often required to undergo maneuvers involving high angles of attack. Under these conditions unsteady vortices emanating from the wing and the fuselage will impinge on the twin fins (required for directional stability) causing excessive buffet loads, in some circumstances, to be applied to the aircraft. These loads result in oscillatory stresses, which may cause significant amounts of fatigue damage. Active control is a possible solution to this important problem. A full-scale test was carried out on an F/A-18 fuselage and fins using piezoceramic actuators to control the vibrations. Buffet loads were simulated using very powerful electromagnetic shakers. The first phase of this test was concerned with the open loop system identification whereas the second stage involved implementing linear time invariant control laws. This paper looks at some of the problems encountered as well as the corresponding solutions and some results. It is expected that flight trials of a similar control system to alleviate buffet will occur as early as 2001.

  8. First neutrino oscillation measurements in NOvA

    DOE PAGES

    Messier, M. D.

    2016-04-20

    In this study, the NOvA experiment uses the Fermilab NuMI neutrino beam and a newly constructed 14 kt detector to address several open questions in neutrino oscillations including the neutrino mass hierarchy, the precise value of the angle θ 23, and the CP-violating phase δ CP. The experiment has been running since 2014 and has recently released its first results from an equivalent exposure of 2.74 × 10 20 protons-on-target equal to 8% of the eventual data set. Measurements of ν μ → ν μ oscillations find Δm 2 32 = (2.52 +0.2 –0.18) × 10 -3 eV 2 andmore » 0.38 < sin 2θ 23 < 0.65 for the normal neutrino mass hierarchy. The experiment has observed ν μ → ν e oscillations at 3.3 σ C.L. in this early data and disfavors the inverted neutrino mass hierarchy in the range 0.1π < δ CP < 0.5π at the 90% C.L.« less

  9. The 3D-architecture of individual free silver nanoparticles captured by X-ray scattering

    DOE PAGES

    Barke, Ingo; Hartmann, Hannes; Rupp, Daniela; ...

    2015-02-04

    The diversity of nanoparticle shapes generated by condensation from gaseous matter reflects the fundamental competition between thermodynamic equilibration and the persistence of metastable configurations during growth. In the kinetically limited regime, intermediate geometries that are favoured only in early formation stages can be imprinted in the finally observed ensemble of differently structured specimens. Here we demonstrate that single-shot wide-angle scattering of femtosecond soft X-ray free-electron laser pulses allows three-dimensional characterization of the resulting metastable nanoparticle structures. For individual free silver particles, which can be considered frozen in space for the duration of photon exposure, both shape and orientation are uncoveredmore » from measured scattering images. We identify regular shapes, including species with fivefold symmetry and surprisingly large aspect ratio up to particle radii of the order of 100 nm. Our approach includes scattering effects beyond Born’s approximation and is remarkably efficient—opening up new routes in ultrafast nanophysics and free-electron laser science« less

  10. Canaloplasty: A Minimally Invasive and Maximally Effective Glaucoma Treatment

    PubMed Central

    Khaimi, Mahmoud A.

    2015-01-01

    Canaloplasty is a highly effective, minimally invasive, surgical technique indicated for the treatment of open-angle glaucoma that works by restoring the function of the eye's natural outflow system. The procedure's excellent safety profile and long-term efficacy make it a viable option for the majority of glaucoma patient types. It can be used in conjunction with existing drug based glaucoma treatments, after laser or other types of incisional surgery, and does not preclude or affect the outcome of future surgery. Numerous scientific studies have shown Canaloplasty to be safe and effective in lowering IOP whilst reducing medication dependence. A recent refinement of Canaloplasty, known as ab-interno Canaloplasty (ABiC), maintains the IOP-lowering and safety benefits of traditional (ab-externo) Canaloplasty using a more efficient, simplified surgical approach. This paper presents a review of Canaloplasty indications, clinical data, and complications, as well as comparisons with traditional incisional glaucoma techniques. It also addresses the early clinical evidence for ABiC. PMID:26495135

  11. Early proximal tibial valgus osteotomy as a very important prognostic factor in Thai children with infantile tibia vara.

    PubMed

    Kaewpornsawan, Kamolporn; Tangsataporn, Suksan; Jatunarapit, Ratiporn

    2005-10-01

    To find the effectiveness of the early surgery (2-3 years of age)as a very important prognostic factor affecting the outcomes in Thai children with infantile tibia vara and all the prognostic factors including the usefulness of arthrographic study in correcting the deformity. From 1994 to 2004, sixteen children aged average 3.61 years old (2.08-7.0) were treated in Siriraj Hospital and diagnosed as infantile tibia vara by Langenskiold radiographic staging were included in the present study and retrospectively reviewed with an average of 6.4 years follow up (range 6 month - 11.1 years). All cases were initially treated by surgery because of low compliance for brace or brace failure. They consisted of 3 boys and 13 girls. There were 24 legs including the bilateral involvement in 8 cases (2 boy and 6 girls). After arihrography, the midshaft fibular osteotomy was performed then the proximal tibial dome-shaped valgus osteotomy was done and fixed with 2 pins. The desired position was 12 degree knee valgus . The patients were divided in two groups, 1)group A,the successful group with the knee becoming normal without any deformity after single osteotomy, 2)group B,the recurrent group with recurrence of the varus deformity required further corrective osteotomies to make normal axis of the knee. All variables were analyzed and compared between group A and group B. The general characteristics and radiographic findings were recorded in 1)age, 2)sex, 3)side, 4)weight in kilogram and in percentage of normal or overweight(obesity) compared with the standard Thai weight chart, 5)tibiofemoral angle (TFA) pre and postoperative treatment, 6) metaphyseal diaphyseal angle (MDA), 7)the medial physeal slope angle (MPS, 8)The preoperative arthrographic articulo-diaphyseal angle (ADA), 9.arthrographic articulo-medial physeal angle (AMPA). There were 14 legs in group A and the remaining 10 legs were in group B (average 2.4 operations). All cases healed in good alignment of the legs without major complication. All patients who were operated on early before 3 years old were 100% cured by single osteotomy in group A(11 legs). Arthrography was useful in evaluating the knee joint and drawing the angle. Considering the prognostic factors affecting the outcomes after surgery, there were 6 prognostic factors . First, the age less than 3 years old (P<0.001). Second, the normal weight (P<0.047). Third, the Langenskiold stage 1-2 (P=0.002). Fourth, the MPS angle equal or less than 59 degree (P < 0.001). Fifth, the ADA preperative angle equal or less than 18 degrees (P<0.001). Sixth and the last factor, the TFA angle postoperative treatment, equal or more than 10 degrees valgus (mean 13 degrees valgus) (P=0.009).In multivariate analysis with stepwise logistic regression of these 6 prosnostic factors, the MPS angle had the most important significance. The proximal tibial valgus osteotomy was a very important factor(P < 0.001). The 6 prognostic factors and usefulness of arthrography were identified. The authors suggest that surgery should be performed early in Thai children who have met these criterias 1)age of the patients more than 2 years old, 2)Langenskiold roentgenographic characteristics of infantile tibia vara stage 2 or more at the time of diagnosis, 3)Low compliance for brace treatment.or brace failure but not more than 3 years old. The surgery should not be delayed more than 3 years of age by waiting for effectiveness of brace treatment in Thai children with infantile tibia vara. The early proximal valgus dome- shaped osteotomy was a very important controllable prognostic factor by surgeon decision.

  12. Comparing approaches to screening for angle closure in older Chinese adults

    PubMed Central

    Andrews, J; Chang, D S; Jiang, Y; He, M; Foster, P J; Munoz, B; Kashiwagi, K; Friedman, D S

    2012-01-01

    Aims Primary angle-closure glaucoma is expected to account for nearly 50% of bilateral glaucoma blindness by 2020. This study was conducted to assess the performance of the scanning peripheral anterior chamber depth analyzer (SPAC) and limbal anterior chamber depth (LACD) as screening methods for angle closure. Methods This study assessed two clinical populations to compare SPAC, LACD, and gonioscopy: the Zhongshan Angle-closure Prevention Trial, from which 370 patients were eligible as closed-angle participants and the Liwan Eye Study, from which 72 patients were selected as open-angle controls. Eligible participants were assessed by SPAC, LACD, and gonioscopy. Results Angle status was defined by gonioscopy. Area under the receiver operating characteristic curve (AUROC) for SPAC was 0.92 (0.89–0.95) whereas AUROC for LACD was 0.94 (0.92–0.97). Using conventional cutoff points, sensitivity/specificity was 93.0%/70.8% for SPAC and 94.1%/87.5% for LACD. Sequential testing using both SPAC and LACD increased the specificity to 94.4% and decreased the sensitivity to 87.0%. Conclusion SPAC has significantly lower specificity than LACD measurement using conventional cutoffs but interpretation of the findings can be performed by modestly trained personnel. PMID:21997356

  13. Magnetic reconnection in 3D magnetosphere models: magnetic separators and open flux production

    NASA Astrophysics Data System (ADS)

    Glocer, A.; Dorelli, J.; Toth, G.; Komar, C. M.; Cassak, P.

    2014-12-01

    There are multiple competing definitions of magnetic reconnection in 3D (e.g., Hesse and Schindler [1988], Lau and Finn [1990], and Boozer [2002]). In this work we focus on separator reconnection. A magnetic separator can be understood as the 3D analogue of a 2D x line with a guide field, and is defined by the line corresponding to the intersection of the separatrix surfaces associated with the magnetic nulls. A separator in the magnetosphere represents the intersection of four distinct magnetic topologies: solar wind, closed, open connected to the northern hemisphere, and open connected to the southern hemisphere. The integral of the parallel electric field along the separator defines the rate of open flux production, and is one measure of the reconnection rate. We present three methods for locating magnetic separators and apply them to 3D resistive MHD simulations of the Earth's magnetosphere using the BATS-R-US code. The techniques for finding separators and determining the reconnection rate are insensitive to IMF clock angle and can in principle be applied to any magnetospheric model. The present work examines cases of high and low resistivity, for two clock angles. We also examine the separator during Flux Transfer Events (FTEs) and Kelvin-Helmholtz instability.

  14. Evaluation of a Wedge on a Force Balance as a Flow Angle Probe

    DTIC Science & Technology

    1975-02-01

    pitot rake attached to the Captive Trajectory System (CTS), and (3) measurement of flow angles in the same region with a probe attached to the CTS...localized pressures. Although it was the characteristics of supersonic flow which led to this conclusion, and even though the wedge design was based...vary the open area from near zero to 10 percent. Suction through the porous walls is used to maximize flow uniformity and to develop supersonic flow

  15. Hot spots in the microwave sky

    NASA Technical Reports Server (NTRS)

    Vittorio, Nicola; Juszkiewicz, Roman

    1987-01-01

    Tha assumption that the cosmic background fluctuations can be approximated as a random Gaussian field implies specific predictions for the radiation temperature pattern. Using this assumption, the abundances and angular sizes are calculated for regions of various levels of brightness expected to appear in the sky. Different observational strategies are assessed in the context of these results. Calculations for both large-angle and small-angle anisotropy generated by scale-invariant fluctuations in a flat universe are presented. Also discussed are simple generalizations to open cosmological models.

  16. Electric Dipole-Magnetic Dipole Polarizability and Anapole Magnetizability of Hydrogen Peroxide as Functions of the HOOH Dihedral Angle.

    PubMed

    Pelloni, S; Provasi, P F; Pagola, G I; Ferraro, M B; Lazzeretti, P

    2017-12-07

    The trace of tensors that account for chiroptical response of the H 2 O 2 molecule is a function of the HO-OH dihedral angle. It vanishes at 0° and 180°, due to the presence of molecular symmetry planes, but also for values in the range 90-100° of this angle, in which the molecule is unquestionably chiral. Such an atypical effect is caused by counterbalancing contributions of diagonal tensor components with nearly maximal magnitude but opposite sign, determined by electron flow in open or closed helical paths, and associated with induced electric and magnetic dipole moments and anapole moments. For values of dihedral angle external to the 90-100° interval, the helical paths become smaller in size, thus reducing the amount of cancellation among diagonal components. Shrinking of helical paths determines the appearance of extremum values of tensor traces approximately at 50° and 140° dihedral angles.

  17. Pathological (late) fractures of the mandibular angle after lower third molar removal: a case series.

    PubMed

    Cutilli, Tommaso; Bourelaki, Theodora; Scarsella, Secondo; Fabio, Desiderio Di; Pontecorvi, Emanuele; Cargini, Pasqualino; Junquera, Luis

    2013-04-30

    Pathological (late) fracture of the mandibular angle after third molar surgery is very rare (0.005% of third molar removals). There are 94 cases reported in the literature; cases associated with osseous pathologies such as osteomyelitis or any local and systemic diseases that may compromise mandibular bone strength have not been included. We describe three new cases of pathological (late) fracture of the mandibular angle after third molar surgery. The first patient was a 27-year-old Caucasian man who had undergone surgical removal of a 3.8, mesioangular variety, class II-C third molar 20 days before admission to our clinic. The fracture of his left mandibular angle, complete and composed, occurred during chewing. The second patient was a 32-year-old Caucasian man. He had undergone surgical removal of a 3.8, mesioangular variety, class II-B third molar 22 days before his admission. The fracture, which occurred during mastication, was studied by computed tomography that showed reparative tissue in the fracture site. The third patient was a 36-year-old Caucasian man who had undergone surgical removal of a 3.8, vertical variety, class II-C third molar 25 days before the observation. In this case the fracture of his mandibular angle was oblique (unfavorable), complete and composed. The fracture had occurred during chewing. We studied the fracture by optical projection tomography and computed tomography.All of the surgical removals of the 3.8 third molars, performed by the patients' dentists who had more than 10 years of experience, were difficult. We treated the fractures with open surgical reduction, internal fixation by titanium miniplates and intermaxillary elastic fixation removed after 6 weeks. The literature indicates that the risk of pathological (late) fracture of the mandibular angle after third molar surgery for total inclusions (class II-III, type C) is twice that of partial inclusions due to the necessity of ostectomies more generous than those for partial inclusions. Other important factors are the anatomy of the teeth and the features of the teeth roots. These fractures predominantly occur in patients who are older than 25 years. The highest incidence (67.8% of cases) is found in the second and third week postsurgery. We emphasize that before the third molar surgery it is extremely important to always provide adequate instructions to the patient in order to avoid early masticatory loads and prevent this rare event.

  18. Frequency doubling technique perimetry and spectral domain optical coherence tomography in patients with early glaucoma.

    PubMed

    Horn, F K; Mardin, C Y; Bendschneider, D; Jünemann, A G; Adler, W; Tornow, R P

    2011-01-01

    To assess the combined diagnostic power of frequency-doubling technique (FDT)-perimetry and retinal nerve fibre layer (RNFL) thickness measurements with spectral domain optical coherence tomography (SDOCT). The study included 330 experienced participants in five age-related groups: 77 'preperimetric' open-angle glaucoma (OAG) patients, 52 'early' OAG, 50 'moderate' OAG, 54 ocular hypertensive patients, and 97 healthy subjects. For glaucoma assessment in all subjects conventional perimetry, evaluation of fundus photographs, FDT-perimetry and RNFL thickness measurement with SDOCT was done. Glaucomatous visual field defects were classified using the Glaucoma Staging System. FDT evaluation used a published method with casewise calculation of an 'FDT-score', including all missed localized probability levels. SDOCT evaluation used mean RNFL thickness and a new individual SDOCT-score considering normal confidence limits in 32 sectors of a peripapillary circular scan. To examine the joined value of both methods a combined score was introduced. Significance of the difference between Receiver-operating-characteristic (ROC) curves was calculated for a specificity of 96%. Sensitivity in the preperimetric glaucoma group was 44% for SDOCT-score, 25% for FDT-score, and 44% for combined score, in the early glaucoma group 83, 81, and 89%, respectively, and in the moderate glaucoma group 94, 94, and 98%, respectively, all at a specificity of 96%. ROC performance of the newly developed combined score is significantly above single ROC curves of FDT-score in preperimetric and early OAG and above RNFL thickness in moderate OAG. Combination of function and morphology by using the FDT-score and the SDOCT-score performs equal or even better than each single method alone.

  19. Frequency doubling technique perimetry and spectral domain optical coherence tomography in patients with early glaucoma

    PubMed Central

    Horn, F K; Mardin, C Y; Bendschneider, D; Jünemann, A G; Adler, W; Tornow, R P

    2011-01-01

    Purpose To assess the combined diagnostic power of frequency-doubling technique (FDT)-perimetry and retinal nerve fibre layer (RNFL) thickness measurements with spectral domain optical coherence tomography (SDOCT). Methods The study included 330 experienced participants in five age-related groups: 77 ‘preperimetric' open-angle glaucoma (OAG) patients, 52 ‘early' OAG, 50 ‘moderate' OAG, 54 ocular hypertensivepatients, and 97 healthy subjects. For glaucoma assessment in all subjects conventional perimetry, evaluation of fundus photographs, FDT-perimetry and RNFL thickness measurement with SDOCT was done. Glaucomatous visual field defects were classified using the Glaucoma Staging System. FDT evaluation used a published method with casewise calculation of an ‘FDT-score', including all missed localized probability levels. SDOCT evaluation used mean RNFL thickness and a new individual SDOCT-score considering normal confidence limits in 32 sectors of a peripapillary circular scan. To examine the joined value of both methods a combined score was introduced. Significance of the difference between Receiver-operating-characteristic (ROC) curves was calculated for a specificity of 96%. Results Sensitivity in the preperimetric glaucoma group was 44% for SDOCT-score, 25% for FDT-score, and 44% for combined score, in the early glaucoma group 83, 81, and 89%, respectively, and in the moderate glaucoma group 94, 94, and 98%, respectively, all at a specificity of 96%. ROC performance of the newly developed combined score is significantly above single ROC curves of FDT-score in preperimetric and early OAG and above RNFL thickness in moderate OAG. Conclusion Combination of function and morphology by using the FDT-score and the SDOCT-score performs equal or even better than each single method alone. PMID:21102494

  20. Clustering of water molecules in ultramicroporous carbon: In-situ small-angle neutron scattering

    DOE PAGES

    Bahadur, Jitendra; Contescu, Cristian I.; Rai, Durgesh K.; ...

    2016-10-19

    The adsorption of water is central to most of the applications of microporous carbon as adsorbent material. We report early kinetics of water adsorption in the microporous carbon using in-situ small-angle neutron scattering. It is observed that adsorption of water occurs via cluster formation of molecules. Interestingly, the cluster size remains constant throughout the adsorption process whereas number density of clusters increases with time. The role of surface chemistry of microporous carbon on the early kinetics of adsorption process was also investigated. Lastly, the present study provides direct experimental evidence for cluster assisted adsorption of water molecules in microporous carbonmore » (Do-Do model).« less

  1. 33 CFR 157.21 - Subdivision and stability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... account sinkage, heel, and trim, must be below the lower edge of an opening through which progressive.... (b) In the final stage of flooding, the angle of heel due to unsymmetrical flooding must not exceed...

  2. 33 CFR 157.21 - Subdivision and stability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... account sinkage, heel, and trim, must be below the lower edge of an opening through which progressive.... (b) In the final stage of flooding, the angle of heel due to unsymmetrical flooding must not exceed...

  3. Evaluation of open graded friction course (OGFC) mixtures.

    DOT National Transportation Integrated Search

    2013-10-01

    Louisiana Department of Transportation and Development (LADOTD) began the development of Open-Graded : Friction Course (OGFC) mixtures in the late 1960s and early 1970s. In the early 1980s, a moratorium was : imposed on the use of OGFC mixtures due t...

  4. Experimental measurements of heat transfer coefficient in a partially/fully opened tilted cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chakroun, W.; Elsayed, M.M.; Al-Fahed, S.F.

    1997-11-01

    An experimental investigation was carried out to determine the heat transfer coefficient from a rectangular tilted cavity to the ambient due to the buoyancy driven flow in the cavity. The cavity is partially or fully open from one side. All the walls of the cavity are adiabatic except the wall facing the cavity opening which is heated at a constant heat flux. Air was used as the cavity fluid and the experiments were carried out at a flux Grashof number of 5.5 {times} 10{sup 8}. The tilt angle of the cavity, measured from the vertical direction, was changed between {minus}90more » deg to +90 deg in 15 deg increments. Also, geometries of aspect ratio (height-to-width of cavity) of 1.0, 0.5, and 0.25 and of opening ratio (opening height to cavity height) of 1.0, 0.5, and 0.25 were considered in the study. The results are presented in terms of the average Nusselt number for different values of the above experimental parameters. Conclusions are derived for the effect of changing the tilt angle, the aspect ratio, or the opening ratio of the cavity on the average heat transfer coefficient between the cavity and the ambient air. Buoyancy-driven flow in rectangular cavities has been widely investigated by many researchers. This geometry is of special interest in many solar applications such as in solar passive heating, solar concentrators, and solar central receivers. The importance of the geometry extends to other engineering applications such as electronic equipment, fire research, and energy conservation in buildings.« less

  5. Preserve the (intraocular) environment: the importance of maintaining normal oxygen gradients in the eye.

    PubMed

    Beebe, David C; Shui, Ying-Bo; Siegfried, Carla J; Holekamp, Nancy M; Bai, Fang

    2014-05-01

    Oxygen levels in the eye are generally low and tightly regulated. Oxygen enters the eye largely by diffusion from retinal arterioles and through the cornea. In intact eyes, oxygen from the retinal arterioles diffuses into the vitreous body. There is a decreasing oxygen gradient from the retina to the lens, established by oxygen consumption by ascorbate in the vitreous fluid and lens metabolism. Age-related degeneration of the vitreous body or removal during vitrectomy exposes the posterior of the lens to increased oxygen, causing nuclear sclerotic cataracts. Lowering oxygen in the vitreous, as occurs in patients with ischemic diabetic retinopathy, protects against cataracts after vitrectomy. Vitrectomy and cataract surgery increase oxygen levels at the trabecular meshwork and with it the risk of open angle glaucoma. Two additional risk factors for glaucoma, African heritage and having a thinner cornea, are also associated with increased oxygen in the anterior chamber angle. Preservation of the vitreous body and the lens, two important oxygen consumers, would protect against nuclear sclerotic cataracts and open angle glaucoma. Delaying removal of the lens for as long as possible after vitrectomy would be an important step in delaying ocular hypertension and glaucoma progression.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamamoto, Seiichi, E-mail: s-yama@met.nagoya-u.ac.jp; Okumura, Satoshi; Komori, Masataka

    We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types ofmore » gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image guides were used to arrange the two scintillator blocks at 22.5° so that they can be arranged in a hexadecagonal shape with eight block detectors to simplify the reconstruction algorithm. The detector ring was divided into two halves to realize the open-mode and set on a mechanical stand with which the distance between the two parts can be manually changed. The spatial resolution in the close-mode was 2.4-mm FWHM, and the sensitivity was 1.7% at the center of the field-of-view. In both the close- and open-modes, we made sagittal (y-z plane) projection images between the two halved detector rings. We obtained reconstructed and projection images of {sup 18}F-NaF rat studies and proton-irradiated phantom images. These results indicate that our developed Open-close PET is useful for some applications such as proton therapy as well as other applications such as molecular imaging.« less

  7. Spatial range of illusory effects in Müller-Lyer figures.

    PubMed

    Predebon, J

    2001-11-01

    The spatial range of the illusory effects in Müller-Lyer (M-L) figures was examined in three experiments. Experiments 1 and 2 assessed the pattern of bisection errors along the shaft of the standard or double-angle (experiment 1) and the single-angle (experiment 2) M-L figures: Subjects bisected the shaft and the resulting two half-segments of the shaft to produce apparently equal quarters, and then each of the quarters to produce eight equal-appearing segments. The bisection judgments of each segment were referenced to the segment's physical midpoints. The expansion or wings-out and the contraction or wings-in figures yielded similar patterns of bisection errors. For the standard M-L figures, there were significant errors in bisecting each half, and each end-quarter, but not the two central quarters of the shaft. For the single-angle M-L figures, there were significant errors in bisecting the length of the shaft, the half-segment, and the quarter, of the shaft adjacent to the vertex but not the second quarter from the vertex nor in dividing the half of the shaft at the open end of the figure into four equal intervals. Experiment 3 assessed the apparent length of the half-segment of the shaft at the open end of the single-angle figures. Length judgments were unaffected by the vertex at the opposite end of the shaft. Taken together, the results indicate that the length distortions in both the standard and single-angle M-L figures are not uniformly distributed along the shaft but rather are confined mainly to the quarters adjacent to the vertices. The present findings imply that theories of the M-L illusion which assume uniform expansion or contraction of the shafts are incomplete.

  8. Medial meniscus posterior root tear induces pathological posterior extrusion of the meniscus in the knee-flexed position: An open magnetic resonance imaging analysis.

    PubMed

    Masuda, S; Furumatsu, T; Okazaki, Y; Kodama, Y; Hino, T; Kamatsuki, Y; Miyazawa, S; Ozaki, T

    2018-04-10

    A medial meniscus posterior root tear (MMPRT) is defined as an injury to the posterior meniscal insertion on the tibia. In MMPRT, the medial meniscus (MM) hoop function is damaged, and the MM undergoes a medial extrusion into the interior from the superior articular surface of the tibia. However, the details of MM position and movement during knee joint movement are unclear in MMPRT cases. The present study aims to evaluate MM position and movement via magnetic resonance imaging (MRI) examination of the MM posterior extrusion (MMPE) at knee flexion angles of 10° and 90°. We hypothesized that, during knee flexion, the MM will shift to the posterior and the posterior extrusion will increase compared to that when the knee is extended. Twenty-four patients were diagnosed with symptomatic MMPRT on open MRI examination. Preoperative MMPE, anteroposterior interval (API) of the MM, and MM medial extrusion (MMME) at knee flexion angles of 10° and 90° were measured. For patients with MMPRT, the MMPE increased from -4.77±1.43mm to 3.79±1.17mm (p<0.001) when the knee flexion angle increased from 10° to 90°. Further, flexing the knee from 10° to 90° decreased the API of the MM from 20.19±4.22mm to 16.41±5.14mm (p<0.001). MMME showed no significant change between knee flexion angles of 10° and 90°. This study demonstrated that, in cases of MMPRT, the MMPE clearly increases when the knee is flexed to 90°, while MMME does not change. Our results suggest that open MRI examination can be used to evaluate the dynamic position of the posterior MM by scanning the knee as it flexes to 90°. IV: retrospective cohort study. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  9. Evaluation of open graded friction course (OGFC) mixtures : [tech summary].

    DOT National Transportation Integrated Search

    2013-10-01

    Louisiana Department of Transportation and Development (LADOTD) began the development of Open-Graded Friction : Course (OGFC) mixtures in the late 1960s and early 1970s. In the early 1980s, a moratorium was imposed on the use : of OGFC mixtures due t...

  10. Initial experience with purely laparoscopic living-donor right hepatectomy.

    PubMed

    Hong, S K; Lee, K W; Choi, Y; Kim, H S; Ahn, S W; Yoon, K C; Kim, H; Yi, N J; Suh, K S

    2018-05-01

    There may be concerns about purely laparoscopic donor right hepatectomy (PLDRH) compared with open donor right hepatectomy, especially when performed by surgeons accustomed to open surgery. This study aimed to describe technical tips and pitfalls in PLDRH. Data from donors who underwent PLDRH at Seoul National University Hospital between December 2015 and July 2017 were analysed retrospectively. Endpoints analysed included intraoperative events and postoperative complications. All operations were performed by a single surgeon with considerable experience in open living donor hepatectomy. A total of 26 donors underwent purely laparoscopic right hepatectomy in the study interval. No donor required transfusion during surgery, whereas two underwent reoperation. In two donors, the dissection plane at the right upper deep portion of the midplane was not correct. One donor experienced portal vein injury during caudate lobe transection, and one developed remnant left hepatic duct stenosis. One donor experienced remnant portal vein angulation owing to a different approach angle, and one experienced arterial damage associated with the use of a laparoscopic energy device. One donor had postoperative bleeding due to masking of potential bleeding foci owing to intra-abdominal pressure during laparoscopy. Two donors experienced right liver surface damage caused by a xiphoid trocar. Purely laparoscopic donor hepatectomy differs from open donor hepatectomy in terms of angle and caudal view. Therefore, surgeons experienced in open donor hepatectomy must gain adequate experience in laparoscopic liver surgery and make adjustments when performing PLDRH. © 2018 BJS Society Ltd Published by John Wiley & Sons Ltd.

  11. Early Detection of Progressive Adolescent Idiopathic Scoliosis: A Severity Index.

    PubMed

    Skalli, Wafa; Vergari, Claudio; Ebermeyer, Eric; Courtois, Isabelle; Drevelle, Xavier; Kohler, Remi; Abelin-Genevois, Kariman; Dubousset, Jean

    2017-06-01

    Early detection of progressive adolescent idiopathic scoliosis (AIS) was assessed based on 3D quantification of the deformity. Based on 3D quantitative description of scoliosis curves, the aim is to assess a specific phenotype that could be an early detectable severity index for progressive AIS. Early detection of progressive scoliosis is important for adapted treatment to limit progression. However, progression risk assessment is mainly based on the follow up, waiting for signs of rapid progression that generally occur during the growth peak. Sixty-five mild scoliosis (16 boys, 49 girls, Cobb Angle between 10 and 20°) with a Risser between 0 and 2 were followed from their first examination until a decision was made by the clinician, either considering the spine as stable at the end of growth (26 patients) or planning to brace because of progression (39 patients). Calibrated biplanar x-rays were performed and 3D reconstructions of the spine allowed calculating six local parameters related to main curve deformity. For progressive curve 3D phenotype assessment, data were compared with those previously assessed for 30 severe scoliosis (Cobb Angle > 35°), 17 scoliosis before brace (Cobb Angle > 29°) and 53 spines of nonscoliosis subjects. A predictive discriminant analysis was performed to assess similarity of mild scoliosis curves either to those of scoliosis or nonscoliosis spines, yielding a severity index (S-index). S-index value at first examination was compared with clinical outcome. At the first exam, 53 out of 65 predictions (82%) were in agreement with actual clinical outcome. Approximately, 89% of the curves that were predicted as progressive proved accurate. Although still requiring large scale validation, results are promising for early detection of progressive curves. 2.

  12. Miniaturized CARS microendoscope probe design for label-free intraoperative imaging

    NASA Astrophysics Data System (ADS)

    Chen, Xu; Wang, Xi; Xu, Xiaoyun; Cheng, Jie; Liu, Zhengfan; Weng, Sheng; Thrall, Michael J.; Goh, Alvin C.; McCormick, Daniel T.; Wong, Kelvin; Wong, Stephen T. C.

    2014-03-01

    A Coherent Anti-Stokes Raman Scattering (CARS) microendoscope probe for early stage label-free prostate cancer diagnosis at single cell resolution is presented. The handheld CARS microendoscope probe includes a customized micro-electromechanical systems (MEMS) scanning mirror as well as miniature optical and mechanical components. In our design, the excitation laser (pump and stokes beams) from the fiber is collimated, reflected by the reflecting mirror, and transmitted via a 2D MEMS scanning mirror and a micro-objective system onto the sample; emission in the epi-direction is returned through the micro-objective lens, MEMS and reflecting mirror, and collimation system, and finally the emission signal is collected by a photomultiplier tube (PMT). The exit pupil diameter of the collimator system is designed to match the diameter of the MEMS mirror and the entrance pupil diameter of the micro-objective system. The back aperture diameter of the micro-objective system is designed according to the largest MEMS scanning angle and the distance between the MEMS mirror and the back aperture. To increase the numerical aperture (NA) of the micro-objective system in order to enhance the signal collection efficiency, the back aperture diameter of the micro-objective system is enlarged with an upfront achromatic wide angle Keplerian telescope beam expander. The integration of a miniaturized micro-optics probe with optical fiber CARS microscopy opens up the possibility of in vivo molecular imaging for cancer diagnosis and surgical intervention.

  13. The Arabidopsis LAZY1 Family Plays a Key Role in Gravity Signaling within Statocytes and in Branch Angle Control of Roots and Shoots[OPEN

    PubMed Central

    Taniguchi, Masatoshi; Furutani, Masahiko; Nishimura, Takeshi; Nakamura, Moritaka; Fushita, Toyohito; Iijima, Kohta; Baba, Kenichiro; Toyota, Masatsugu

    2017-01-01

    During gravitropism, the directional signal of gravity is perceived by gravity-sensing cells called statocytes, leading to asymmetric distribution of auxin in the responding organs. To identify the genes involved in gravity signaling in statocytes, we performed transcriptome analyses of statocyte-deficient Arabidopsis thaliana mutants and found two candidates from the LAZY1 family, AtLAZY1/LAZY1-LIKE1 (LZY1) and AtDRO3/AtNGR1/LZY2. We showed that LZY1, LZY2, and a paralog AtDRO1/AtNGR2/LZY3 are redundantly involved in gravitropism of the inflorescence stem, hypocotyl, and root. Mutations of LZY genes affected early processes in gravity signal transduction without affecting amyloplast sedimentation. Statocyte-specific expression of LZY genes rescued the mutant phenotype, suggesting that LZY genes mediate gravity signaling in statocytes downstream of amyloplast displacement, leading to the generation of asymmetric auxin distribution in gravity-responding organs. We also found that lzy mutations reversed the growth angle of lateral branches and roots. Moreover, expression of the conserved C-terminal region of LZY proteins also reversed the growth direction of primary roots in the lzy mutant background. In lateral root tips of lzy multiple mutants, asymmetric distribution of PIN3 and auxin response were reversed, suggesting that LZY genes regulate the direction of polar auxin transport in response to gravity through the control of asymmetric PIN3 expression in the root cap columella. PMID:28765510

  14. Development of a GIS-based failure investigation system for highway soil slopes

    NASA Astrophysics Data System (ADS)

    Ramanathan, Raghav; Aydilek, Ahmet H.; Tanyu, Burak F.

    2015-06-01

    A framework for preparation of an early warning system was developed for Maryland, using a GIS database and a collective overlay of maps that highlight highway slopes susceptible to soil slides or slope failures in advance through spatial and statistical analysis. Data for existing soil slope failures was collected from geotechnical reports and field visits. A total of 48 slope failures were recorded and analyzed. Six factors, including event precipitation, geological formation, land cover, slope history, slope angle, and elevation were considered to affect highway soil slope stability. The observed trends indicate that precipitation and poor surface or subsurface drainage conditions are principal factors causing slope failures. 96% of the failed slopes have an open drainage section. A majority of the failed slopes lie in regions with relatively high event precipitation ( P>200 mm). 90% of the existing failures are surficial erosion type failures, and only 1 out of the 42 slope failures is deep rotational type failure. More than half of the analyzed slope failures have occurred in regions having low density land cover. 46% of failures are on slopes with slope angles between 20° and 30°. Influx of more data relating to failed slopes should give rise to more trends, and thus the developed slope management system will aid the state highway engineers in prudential budget allocation and prioritizing different remediation projects based on the literature reviewed on the principles, concepts, techniques, and methodology for slope instability evaluation (Leshchinsky et al., 2015).

  15. Macular thickness after glaucoma filtration surgery.

    PubMed

    Sesar, Antonio; Cavar, Ivan; Sesar, Anita Pusić; Geber, Mia Zorić; Sesar, Irena; Laus, Katia Novak; Vatavuk, Zoran; Mandić, Zdravko

    2013-09-01

    The aim of present study was to analyze early postoperative changes in the macular area using optical coherence tomography (OCT) after uncomplicated glaucoma filtration surgery. This prospective study included 32 patients (34 eyes) with open-angle glaucoma, which underwent trabeculectomy with or without use of mitomycin C. Exclusion criteria were macular edema, uveitis, age-related macular degeneration, blurred optical media, secondary glaucoma and angle-closure glaucoma. All standard clinical examinations were made before surgery, at the 2nd day, 1 week and 1 month after surgery. Tomography of the macula was performed during every examination using Cirrus HD OCT for the analysis of central subfield thickness. Results show that thickening of the macula was slightly higher 1 week and 1 month after operation in comparison with baseline end 2nd day postoperativelly. There was no significant difference in the change of macular thickness in patients who have used topical prostaglandins compared with those who have used other topical medications. Also, there was no difference in macular changes between patients treated with or without mitomycin C. In conclusion, we found a slight subclinical increase in macular thickness after uncomplicated trabeculectomy, for which we considered that was the result in reduction of intraocular pressure after glaucoma surgery. Macular thickening after glaucoma filtering surgery could be a physiological reaction to the stress of the retina caused by a sudden reduction of intraocular pressure and it is the consequence of altered relationship between capillary pressure and interstitial fluid pressure.

  16. Generalized Brewster effect in dielectric metasurfaces

    PubMed Central

    Paniagua-Domínguez, Ramón; Yu, Ye Feng; Miroshnichenko, Andrey E.; Krivitsky, Leonid A.; Fu, Yuan Hsing; Valuckas, Vytautas; Gonzaga, Leonard; Toh, Yeow Teck; Kay, Anthony Yew Seng; Luk'yanchuk, Boris; Kuznetsov, Arseniy I.

    2016-01-01

    Polarization is a key property defining the state of light. It was discovered by Brewster, while studying light reflected from materials at different angles. This led to the first polarizers, based on Brewster's effect. Now, one of the trends in photonics is the study of miniaturized devices exhibiting similar, or improved, functionalities compared with bulk optical elements. In this work, it is theoretically predicted that a properly designed all-dielectric metasurface exhibits a generalized Brewster's effect potentially for any angle, wavelength and polarization of choice. The effect is experimentally demonstrated for an array of silicon nanodisks at visible wavelengths. The underlying physics is related to the suppressed scattering at certain angles due to the interference between the electric and magnetic dipole resonances excited in the nanoparticles. These findings open doors for Brewster phenomenon to new applications in photonics, which are not bonded to a specific polarization or angle of incidence. PMID:26783075

  17. Increasing light coupling in a photovoltaic film by tuning nanoparticle shape with substrate surface energy

    NASA Astrophysics Data System (ADS)

    Kataria, Devika; Krishnamoorthy, Kothandam; Iyer, S. Sundar Kumar

    2017-08-01

    Tuning metal nanoparticle (MNP) contact angle on the surface it is formed can help maximise the useful optical coupling in photovoltaic films by localized surface plasmon (LSP) resonance—opening up the possibility of building improved photovoltaic cells. In this work experimental demonstration of optical absorption increase in copper phthalocyanine (CuPc) films by tuning silver MNP shape by changing its contact angles with substrate has been reported. Thin films of poly3,4 ethylenedioxythiophene: sodium dodecycl sulphate (PEDOT:SDS) with different surface energies were formed on indium tin oxide (ITO) coated glass by electro-deposition. Silver MNPs thermally evaporated directly on ozonised ITO as well as on the PEDOT:SDS films showed contact angles ranging from 60° to 125°. The CuPc layer was deposited on top of the MNPs. For the samples studied, best optical absorption in the CuPc layer was for a contact angle of 110°.

  18. Optimal operation of turbo blowers serially connected using inlet vanes

    NASA Astrophysics Data System (ADS)

    Jang, Choon-Man

    2011-03-01

    Optimal operation of the turbo blowers having an inlet vane has been studied to understand the blowers' operating performance. To analyze three-dimensional flow field in the turbo blowers serially connected, general analysis code, CFX, is introduced in the present work. SST turbulence model is employed to estimate the eddy viscosity. Throughout the numerical analysis, it is found that the flow rates of the turbo blowers can be controlled at the vane angle between 90 (full open condition) degrees and 60 degrees effectively, because pressure loss rapidly increases below 60 degree of a vane angle. Efficiency also has almost the same values from 90 degrees to 60 degrees of a vane angle. It is noted that the distorted inlet velocity generated in the small vane angle makes performance deterioration of the turbo blowers due to the local leading edge separation and the following non-uniform blade loading.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    García-Cervantes, H.; Sotolongo-Costa, O.; Gaggero-Sager, L. M.

    Graphene Superlattices (GSs) have attracted a lot of attention due to its peculiar properties as well as its possible technological implications. Among these characteristics we can mention: the extra Dirac points in the dispersion relation and the highly anisotropic propagation of the charge carriers. However, despite the intense research that is carried out in GSs, so far there is no report about the angular dependence of the Transmission Gap (TG) in GSs. Here, we report the dependence of TG as a function of the angle of the incident Dirac electrons in a rather simple Electrostatic GS (EGS). Our results showmore » that the angular dependence of the TG is intricate, since for moderated angles the dependence is parabolic, while for large angles an exponential dependence is registered. We also find that the TG can be modulated from meV to eV, by changing the structural parameters of the GS. These characteristics open the possibility for an angle-dependent bandgap engineering in graphene.« less

  20. 75 FR 69737 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-15

    ... moving violations in a CMV. Michael E. Herrera, Jr., Mr. Herrera, 53, has had primary open angle glaucoma... opinion. Mr. Herrera has sufficient vision to drive a commercial vehicle. Mr. Herrera reported that he has...

  1. Bend losses in rectangular culverts.

    DOT National Transportation Integrated Search

    2008-09-01

    This study investigated bend losses for open channel flow in rectangular channels or culverts. Laboratory experiments were performed for sub-critical flow in rectangular channels with abrupt bends. Bend angles of approximately 30, 45, 60, 75 and 90 d...

  2. Laser beam guard clamps

    DOEpatents

    Dickson, Richard K.

    2010-09-07

    A quick insert and release laser beam guard panel clamping apparatus having a base plate mountable on an optical table, a first jaw affixed to the base plate, and a spring-loaded second jaw slidably carried by the base plate to exert a clamping force. The first and second jaws each having a face acutely angled relative to the other face to form a V-shaped, open channel mouth, which enables wedge-action jaw separation by and subsequent clamping of a laser beam guard panel inserted through the open channel mouth. Preferably, the clamping apparatus also includes a support structure having an open slot aperture which is positioned over and parallel with the open channel mouth.

  3. Micromechanical torsional digital-to-analog converter for open-loop angular positioning applications

    NASA Astrophysics Data System (ADS)

    Zhou, Guangya; Tay, Francis E. H.; Chau, Fook Siong; Zhao, Yi; Logeeswaran, VJ

    2004-05-01

    This paper reports a novel micromechanical torsional digital-to-analog converter (MTDAC), operated in open-loop with digitally controlled precise multi-level tilt angles. The MTDAC mechanism presented is analogous to that of an electrical binary-weighted-input digital-to-analog converter (DAC). It consists of a rigid tunable platform, an array of torsional microactuators, each operating in a two-state (on/off) mode, and a set of connection beams with binary-weighted torsional stiffnesses that connect the actuators to the platform. The feasibility of the proposed MTDAC mechanism was verified numerically by finite element simulations and experimentally with a commercial optical phase-shifting interferometric system. A prototype 2-bit MTDAC was implemented using the poly-MUMPS process achieving a full-scale output tilt angle of 1.92° with a rotation step of 0.64°. This mechanism can be configured for many promising applications, particularly in beam steering-based OXC switches.

  4. Common variants near CAV1 and CAV2 are associated with primary open-angle glaucoma

    PubMed Central

    Thorleifsson, Gudmar; Walters, G Bragi; Hewitt, Alex W; Masson, Gisli; Helgason, Agnar; DeWan, Andrew; Sigurdsson, Asgeir; Jonasdottir, Adalbjorg; Gudjonsson, Sigurjon A; Magnusson, Kristinn P; Stefansson, Hreinn; Lam, Dennis S C; Tam, Pancy O S; Gudmundsdottir, Gudrun J; Southgate, Laura; Burdon, Kathryn P; Gottfredsdottir, Maria Soffia; Aldred, Micheala A; Mitchell, Paul; St Clair, David; Collier, David A; Tang, Nelson; Sveinsson, Orn; Macgregor, Stuart; Martin, Nicholas G; Cree, Angela J; Gibson, Jane; MacLeod, Alex; Jacob, Aby; Ennis, Sarah; Young, Terri L; Chan, Juliana C N; Karwatowski, Wojciech S S; Hammond, Christopher J; Thordarson, Kristjan; Zhang, Mingzhi; Wadelius, Claes; Lotery, Andrew J; Trembath, Richard C; Pang, Chi Pui; Hoh, Josephine; Craig, Jamie E; Kong, Augustine; Mackey, David A; Jonasson, Fridbert; Thorsteinsdottir, Unnur; Stefansson, Kari

    2011-01-01

    We conducted a genome-wide association study for primary open-angle glaucoma (POAG) in 1,263 affected individuals (cases) and 34,877 controls from Iceland. We identified a common sequence variant at 7q31 (rs4236601[A], odds ratio (OR) = 1.36, P = 5.0 × 10-10). We then replicated the association in sample sets of 2,175 POAG cases and 2,064 controls from Sweden, the UK and Australia (combined OR = 1.18, P = 0.0015) and in 299 POAG cases and 580 unaffected controls from Hong Kong and Shantou, China (combined OR = 5.42, P = 0.0021). The risk variant identified here is located close to CAV1 and CAV2, both of which are expressed in the trabecular meshwork and retinal ganglion cells that are involved in the pathogenesis of POAG. PMID:20835238

  5. Cross-coupling between accommodation and convergence is optimized for a broad range of directions and distances of gaze.

    PubMed

    Nguyen, Dorothy; Vedamurthy, Indu; Schor, Clifton

    2008-03-01

    Accommodation and convergence systems are cross-coupled so that stimulation of one system produces responses by both systems. Ideally, the cross-coupled responses of accommodation and convergence match their respective stimuli. When expressed in diopters and meter angles, respectively, stimuli for accommodation and convergence are equal in the mid-sagittal plane when viewed with symmetrical convergence, where historically, the gains of the cross coupling (AC/A and CA/C ratios) have been quantified. However, targets at non-zero azimuth angles, when viewed with asymmetric convergence, present unequal stimuli for accommodation and convergence. Are the cross-links between the two systems calibrated to compensate for stimulus mismatches that increase with gaze-azimuth? We measured the response AC/A and stimulus CA/C ratios at zero azimuth, 17.5 and 30 deg of rightward gaze eccentricities with a Badal Optometer and Wheatstone-mirror haploscope. AC/A ratios were measured under open-loop convergence conditions along the iso-accommodation circle (locus of points that stimulate approximately equal amounts of accommodation to the two eyes at all azimuth angles). CA/C ratios were measured under open-loop accommodation conditions along the iso-vergence circle (locus of points that stimulate constant convergence at all azimuth angles). Our results show that the gain of accommodative-convergence (AC/A ratio) decreased and the bias of convergence-accommodation increased at the 30 deg gaze eccentricity. These changes are in directions that compensate for stimulus mismatches caused by spatial-viewing geometry during asymmetric convergence.

  6. 3D DEM analyses of the 1963 Vajont rock slide

    NASA Astrophysics Data System (ADS)

    Boon, Chia Weng; Houlsby, Guy; Utili, Stefano

    2013-04-01

    The 1963 Vajont rock slide has been modelled using the distinct element method (DEM). The open-source DEM code, YADE (Kozicki & Donzé, 2008), was used together with the contact detection algorithm proposed by Boon et al. (2012). The critical sliding friction angle at the slide surface was sought using a strength reduction approach. A shear-softening contact model was used to model the shear resistance of the clayey layer at the slide surface. The results suggest that the critical sliding friction angle can be conservative if stability analyses are calculated based on the peak friction angles. The water table was assumed to be horizontal and the pore pressure at the clay layer was assumed to be hydrostatic. The influence of reservoir filling was marginal, increasing the sliding friction angle by only 1.6˚. The results of the DEM calculations were found to be sensitive to the orientations of the bedding planes and cross-joints. Finally, the failure mechanism was investigated and arching was found to be present at the bend of the chair-shaped slope. References Boon C.W., Houlsby G.T., Utili S. (2012). A new algorithm for contact detection between convex polygonal and polyhedral particles in the discrete element method. Computers and Geotechnics, vol 44, 73-82, doi.org/10.1016/j.compgeo.2012.03.012. Kozicki, J., & Donzé, F. V. (2008). A new open-source software developed for numerical simulations using discrete modeling methods. Computer Methods in Applied Mechanics and Engineering, 197(49-50), 4429-4443.

  7. Early Initial Antibiotics and Debridement Independently Reduce Infection in an Open Fracture Model

    DTIC Science & Technology

    2012-01-01

    infection in those Gustilo-Anderson grade III fractures whose surgery was delayed until return to the US, compared with those who underwent early...LEAP) included a prospective observational study of 315 patients with Gustilo-Anderson grade III open fractures of the tibia, foot and ankle and, in...6. Ashford RU, Mehta JA, Cripps R. Delayed presentation is no barrier to satisfactory outcome in the management of open tibial fractures . Injury

  8. Slow relaxation in weakly open rational polygons.

    PubMed

    Kokshenev, Valery B; Vicentini, Eduardo

    2003-07-01

    The interplay between the regular (piecewise-linear) and irregular (vertex-angle) boundary effects in nonintegrable rational polygonal billiards (of m equal sides) is discussed. Decay dynamics in polygons (of perimeter P(m) and small opening Delta) is analyzed through the late-time survival probability S(m) approximately equal t(-delta). Two distinct slow relaxation channels are established. The primary universal channel exhibits relaxation of regular sliding orbits, with delta=1. The secondary channel is given by delta>1 and becomes open when m>P(m)/Delta. It originates from vertex order-disorder dual effects and is due to relaxation of chaoticlike excitations.

  9. Surgical Orthodontic Treatment for Open Bite in Noonan Syndrome Patient: A Case Report.

    PubMed

    Kawakami, Masayoshi; Yamamoto, Kazuhiko; Shimomura, Tadahiro; Kirita, Tadaaki

    2016-03-01

    Noonan syndrome, characterized by short stature, facial anomalies, and congenital heart defects, may also be associated with hematopoietic disorders. Craniofacial anomalies in affected patients include hypertelorism and severe open bite associated with masticatory dysfunction. We treated a Noonan syndrome patient with a skeletal open bite. Surgical orthodontic treatment including two-jaw surgery established a good occlusal relationship after correction of severe anemia. Both upper and lower incisors were moved to upright positions, while clockwise rotation of the palatal plane and decreased mandibular plane angle were accomplished. Lower masticatory activity may affect posttreatment occlusion in such cases.

  10. Acoustic Shielding for a Model Scale Counter-rotation Open Rotor

    NASA Technical Reports Server (NTRS)

    Stephens, David B.; Edmane, Envia

    2012-01-01

    The noise shielding benefit of installing an open rotor above a simplified wing or tail is explored experimentally. The test results provide both a benchmark data set for validating shielding prediction tools and an opportunity for a system level evaluation of the noise reduction potential of propulsion noise shielding by an airframe component. A short barrier near the open rotor was found to provide up to 8.5 dB of attenuation at some directivity angles, with tonal sound particularly well shielded. Predictions from two simple shielding theories were found to overestimate the shielding benefit.

  11. Method of sealing

    DOEpatents

    Groh, Edward F.; Cassidy, Dale A.

    1978-01-01

    A thermocouple lead or other small diameter wire, cable or tube is passed through a thin material such as sheet metal and sealed thereinto by drawing complementary longitudinally angled, laterally rounded grooves terminating at their base ends in a common plane in both sides of the thin material with shearing occuring at the deep end faces thereof to form a rounded opening in the thin material substantially perpendicular to the plane of the thin material, passing a thermocouple lead or similar object through the opening so formed and sealing the opening with a sealant which simultaneously bonds the lead to the thin material.

  12. Modeling the effect of preexisting joints on normal fault geometries using a brittle and cohesive material

    NASA Astrophysics Data System (ADS)

    Kettermann, M.; van Gent, H. W.; Urai, J. L.

    2012-04-01

    Brittle rocks, such as for example those hosting many carbonate or sandstone reservoirs, are often affected by different kinds of fractures that influence each other. Understanding the effects of these interactions on fault geometries and the formation of cavities and potential fluid pathways might be useful for reservoir quality prediction and production. Analogue modeling has proven to be a useful tool to study faulting processes, although usually the used materials do not provide cohesion and tensile strength, which are essential to create open fractures. Therefore, very fine-grained, cohesive, hemihydrate powder was used for our experiments. The mechanical properties of the material are scaling well for natural prototypes. Due to the fine grain size structures are preserved in in great detail. The used deformation box allows the formation of a half-graben and has initial dimensions of 30 cm width, 28 cm length and 20 cm height. The maximum dip-slip along the 60° dipping predefined basement fault is 4.5 cm and was fully used in all experiments. To setup open joints prior to faulting, sheets of paper placed vertically within the box to a depth of about 5 cm from top. The powder was then sieved into the box, embedding the paper almost entirely. Finally strings were used to remove the paper carefully, leaving open voids. Using this method allows the creation of cohesionless open joints while ensuring a minimum impact on the sensitive surrounding material. The presented series of experiments aims to investigate the effect of different angles between the strike of a rigid basement fault and a distinct joint set. All experiments were performed with a joint spacing of 2.5 cm and the fault-joint angles incrementally covered 0°, 4°, 8°, 12°, 16°, 20° and 25°. During the deformation time lapse photography from the top and side captured every structural change and provided data for post-processing analysis using particle imaging velocimetry (PIV). Additionally, stereo-photography at the final stage of deformation enabled the creation of 3D models to preserve basic geometric information. The models showed that at the surface the deformation localized always along preexisting joints, even when they strike at an angle to the basement-fault. In most cases faults intersect precisely at the maximum depth of the joints. With increasing fault-joint angle the deformation occurred distributed over several joints by forming stepovers with fractures oriented normal to the strike of the joints. No fractures were observed parallel to the basement fault. At low angles stepovers coincided with wedge-shaped structures between two joints that remain higher than the surrounding joint-fault intersection. The wide opening gap along the main fault allowed detailed observations of the fault planes at depth, which revealed (1) changing dips according to joint-fault angles, (2) slickenlines, (3) superimposed steepening fault-planes, causing sharp sawtooth-shaped structures. Comparison to a field analogue at Canyonlands National Park, Utah/USA showed similar structures and features such as vertical fault escarpments at the surface coinciding with joint-surfaces. In the field and in the models stepovers were observed as well as conjugate faulting and incremental fault-steepening.

  13. [Changes of structures of anterior chamber angle in rabbit chronic high intraocular pressure model].

    PubMed

    Lei, Xun-wen; Wei, Ping; Li, Xiao-lin; Yang, Kan; Lei, Jian-zhen

    2009-10-01

    To observe the anterior chamber angle changes occurred in compound Carbomer-induced chronic high intraocular pressure (IOP) model in rabbit eyes. It was an experimental study. Thirty two rabbits were randomly divided into eight groups. Compound Carbomer (0.3%, 0.3 ml) was injected into the left anterior chamber. A group of rabbits were randomly killed after 1, 2, 3, 4, 6, 8, 10 and 12 weeks. The anterior chamber of the rabbit eye specimens was observed. IOP increased slowly following the application of the drug, high IOP lasted for 3 months. The drug-induced changes of anterior chamber angle consisted of early inflammatory response and late fibrous changes. Inflammatory response occurred in early stage and reduced or disappeared after 3 weeks. Fibrous degeneration and adhesion obstruction occurred in the anterior chamber angle after 4 weeks. Under the electron microscope, the trabecular was expanded and deformed, with hyperplasia of collagen and elastic fibers. Endothelial cells were separated from the trabecular, and showed the morphology of lymphocytes, with the function similar to the macrophages. Phagocytized Carbomer particles were transported through the vacuoles of Schlemm's canal endothelial cells. Large vacuoles gradually reduced. Excessive Carbomer particles were accumulated in the endothelial cells and obstructed the Schlemm's canal. This induced the fibrous proliferation and the destruction of anterior chamber angle structures. The obstruction of aqueous humor outflow induced by compound Carbomer in rabbit high IOP model is caused mainly by the changes in trabecular endothelial cells.

  14. Infant titi monkey behavior in the open field test and the effect of early adversity

    PubMed Central

    Larke, Rebecca H.; Toubiana, Alice; Lindsay, Katrina A.; Mendoza, Sally P.; Bales, Karen L.

    2017-01-01

    The open field test is commonly used to measure anxiety-related behavior and exploration in rodents. Here, we used it as a standardized novel environment in which to evaluate the behavioral response of infant titi monkeys (Callicebus cupreus), to determine the effect of presence of individual family members, and to assess how adverse early experience alters infant behavior. Infants were tested in the open field for 5 days at ages 4 and 6 months in four successive 5 min trials on each day. A transport cage, which was situated on one side of the open field, was either empty (non-social control) or contained the father, mother, or sibling. Infant locomotor, vocalization, and exploratory behavior were quantified. Results indicated that age, sex, social condition, and early experience all had significant effects on infant behavior. Specifically, infants were generally more exploratory at 6 months and male infants were more exploratory than females. Infants distinguished between social and non-social conditions but made few behavioral distinctions between the attachment figure and other individuals. Infants which had adverse early life experience demonstrated greater emotional and physical independence, suggesting that early adversity led to resiliency in the novel environment. PMID:28605039

  15. Combining electromagnetic gyro-kinetic particle-in-cell simulations with collisions

    NASA Astrophysics Data System (ADS)

    Slaby, Christoph; Kleiber, Ralf; Könies, Axel

    2017-09-01

    It has been an open question whether for electromagnetic gyro-kinetic particle-in-cell (PIC) simulations pitch-angle collisions and the recently introduced pullback transformation scheme (Mishchenko et al., 2014; Kleiber et al., 2016) are consistent. This question is positively answered by comparing the PIC code EUTERPE with an approach based on an expansion of the perturbed distribution function in eigenfunctions of the pitch-angle collision operator (Legendre polynomials) to solve the electromagnetic drift-kinetic equation with collisions in slab geometry. It is shown how both approaches yield the same results for the frequency and damping rate of a kinetic Alfvén wave and how the perturbed distribution function is substantially changed by the presence of pitch-angle collisions.

  16. Low-Angle-Incidence Microchannel Epitaxy of a-Plane GaN Grown by Ammonia-Based Metal-Organic Molecular Beam Epitaxy

    NASA Astrophysics Data System (ADS)

    Lin, Chia-Hung; Uchiyama, Shota; Maruyama, Takahiro; Naritsuka, Shigeya

    2012-04-01

    Low-angle-incidence microchannel epitaxy (LAIMCE) of a-plane GaN was performed using ammonia-based metal-organic molecular beam epitaxy to obtain wide and thin lateral overgrowth over a SiO2 mask. Trimethylgallium (TMG) was supplied perpendicular to the openings cut in the mask with a low incident angle of 5° relative to the substrate plane. The [NH3]/[TMG] ratio (R) dependence of GaN LAIMCE was optimized by varying R from 5 to 30. A wide lateral overgrowth of 3.7 µm with a dislocation density below the transmission electron microscope detection limit was obtained at R=15 for a thickness of 520 nm.

  17. F-18 High Alpha Research Vehicle (HARV) parameter identification flight test maneuvers for optimal input design validation and lateral control effectiveness

    NASA Technical Reports Server (NTRS)

    Morelli, Eugene A.

    1995-01-01

    Flight test maneuvers are specified for the F-18 High Alpha Research Vehicle (HARV). The maneuvers were designed for open loop parameter identification purposes, specifically for optimal input design validation at 5 degrees angle of attack, identification of individual strake effectiveness at 40 and 50 degrees angle of attack, and study of lateral dynamics and lateral control effectiveness at 40 and 50 degrees angle of attack. Each maneuver is to be realized by applying square wave inputs to specific control effectors using the On-Board Excitation System (OBES). Maneuver descriptions and complete specifications of the time/amplitude points define each input are included, along with plots of the input time histories.

  18. Comparative study of the retinal nerve fibre layer thickness performed with optical coherence tomography and GDx scanning laser polarimetry in patients with primary open-angle glaucoma.

    PubMed

    Wasyluk, Jaromir T; Jankowska-Lech, Irmina; Terelak-Borys, Barbara; Grabska-Liberek, Iwona

    2012-03-01

    We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. Study subjects had advanced primary open-angle glaucoma, previously treated conservatively, diagnosed and confirmed by additional examinations (visual field, ophthalmoscopy of optic nerve, gonioscopy), A total of 10 patients were enrolled (9 women and 1 man), aged 18-70 years of age. Nineteen eyes with advanced glaucomatous neuropathy were examined. 1) Performing a threshold perimetry Octopus, G2 strategy and ophthalmoscopy of optic nerve to confirm the presence of advanced primary open-angle glaucoma; 2) performing a GDx VCC scanning laser polarimetry of retinal nerve fibre layer; 3) measuring the retinal nerve fibre layer thickness with 3 different optical coherence tomographs. The parameters of the retinal nerve fibre layer thickness are highly correlated between the GDx and OCT Stratus and 3D OCT-1000 devices in mean retinal nerve fibre layer thickness, retinal nerve fibre layer thickness in the upper sector, and correlation of NFI (GDx) with mean retinal nerve fibre layer thickness in OCT examinations. Absolute values of the retinal nerve fibre layer thickness (measured in µm) differ significantly between GDx and all OCT devices. Examination with OCT devices is a sensitive diagnostic method of glaucoma, with good correlation with the results of GDx scanning laser polarimetry of the patients.

  19. The qualitative scoring MMSE pentagon test (QSPT): a new method for differentiating dementia with Lewy Body from Alzheimer's disease.

    PubMed

    Caffarra, Paolo; Gardini, Simona; Dieci, Francesca; Copelli, Sandra; Maset, Laura; Concari, Letizia; Farina, Elisabetta; Grossi, Enzo

    2013-01-01

    The differential diagnosis across different variants of degenerative diseases is sometimes controversial. This study aimed to validate a qualitative scoring method for the pentagons copy test (QSPT) of Mini-Mental State Examination (MMSE) based on the assessment of different parameters of the pentagons drawing, such as number of angles, distance/intersection, closure/opening, rotation, closing-in, and to verify its efficacy to differentiate dementia with Lewy Body (DLB) from Alzheimer's disease (AD). We established the reliability of the qualitative scoring method through the inter-raters and intra-subjects analysis. QSPT was then applied to forty-six AD and forty-six DLB patients, using two phases statistical approach, standard and artificial neural network respectively. DLB patients had significant lower total score in the copy of pentagons and number of angles, distance/intersection, closure/opening, rotation compared to AD. However the logistic regression did not allow to establish any suitable modeling, whereas using Auto-Contractive Map (Auto-CM) the DLB was more strongly associated with low scores in some qualitative parameters of pentagon copying, i.e. number of angles and opening/closure and, for the remaining subitems of the MMSE, in naming, repetition and written comprehension, and for demographic variables of gender (male) and education (6-13 years). Twist system modeling showed that the QSPT had a good sensitivity (70.29%) and specificity (78.67%) (ROC-AUC 0.74). The proposed qualitative method of assessment of pentagons copying used in combination with non-linear analysis, showed to be consistent and effective in the differential diagnosis between Lewy Body and Alzheimer's dementia.

  20. The impact of in-situ stress and outcrop-based fracture geometry on hydraulic aperture and upscaled permeability in fractured reservoirs

    NASA Astrophysics Data System (ADS)

    Bisdom, Kevin; Bertotti, Giovanni; Nick, Hamidreza M.

    2016-10-01

    Aperture has a controlling impact on porosity and permeability and is a source of uncertainty in modeling of naturally fractured reservoirs. This uncertainty results from difficulties in accurately quantifying aperture in the subsurface and from a limited fundamental understanding of the mechanical and diagenetic processes that control aperture. In the absence of cement bridges and high pore pressure, fractures in the subsurface are generally considered to be closed. However, experimental work, outcrop analyses and subsurface data show that some fractures remain open, and that aperture varies even along a single fracture. However, most fracture flow models consider constant apertures for fractures. We create a stress-dependent heterogeneous aperture by combining Finite Element modeling of discrete fracture networks with an empirical aperture model. Using a modeling approach that considers fractures explicitly, we quantify equivalent permeability, i.e. combined matrix and stress-dependent fracture flow. Fracture networks extracted from a large outcropping pavement form the basis of these models. The results show that the angle between fracture strike and σ1 has a controlling impact on aperture and permeability, where hydraulic opening is maximum for an angle of 15°. At this angle, the fracture experiences a minor amount of shear displacement that allows the fracture to remain open even when fluid pressure is lower than the local normal stress. Averaging the heterogeneous aperture to scale up permeability probably results in an underestimation of flow, indicating the need to incorporate full aperture distributions rather than simplified aperture models in reservoir-scale flow models.

  1. Primary stability of different plate positions and the role of bone substitute in open wedge high tibial osteotomy.

    PubMed

    Takeuchi, Ryohei; Woon-Hwa, Jung; Ishikawa, Hiroyuki; Yamaguchi, Yuichiro; Osawa, Katsunari; Akamatsu, Yasushi; Kuroda, Koichi

    2017-12-01

    The purpose of this study was to compare the mechanical fixation strengths of anteromedial and medial plate positions in osteotomy, and clarify the effects of bone substitute placement into the osteotomy site. Twenty-eight sawbone tibia models were used. Four different models were prepared: Group A, the osteotomy site was open and the plate position was anteromedial; Group B, bone substitutes were inserted into the osteotomy site and the plate position was anteromedial; Group C, the osteotomy site was open and the plate position was medial; and Group D, bone substitutes were inserted into the osteotomy site and the plate position was medial. The loading condition ranged from 0 to 800N and one hertz cycles were applied. Changes of the tibial posterior slope angle (TPS), stress on the plate and lateral hinge were measured. The changes in the TPS and the stress on the plate were significantly larger in Group A than in Group C. These were significantly larger in Group A than in Group B, and in Group C than in Group D. There was no significant difference between Group B and Group D, and no significant difference between knee flexion angles of 0° and 10°. Stress on the lateral hinge was significantly smaller when bone substitute was used. A medial plate position was biomechanically superior to an anteromedial position if bone substitute was not used. Bone substitute distributed the stress concentration around the osteotomy gap and prevented an increase in TPS angle regardless of the plate position. Copyright © 2017. Published by Elsevier B.V.

  2. Reproducibility of intraocular pressure peak and fluctuation of the water-drinking test.

    PubMed

    Hatanaka, Marcelo; Alencar, Luciana M; De Moraes, Carlos G; Susanna, Remo

    2013-01-01

    The water-drinking test has been used as a stress test to evaluate the drainage system of the eye. However, in order to be clinically applicable,a test must provide reproducible results with consistent measurements. This study was performed to verify the reproducibility of intraocular pressure peaks and fluctuation detected during the water-drinking test in patients with ocular hypertension and open-angle glaucoma. A prospective analysis of patients in a tertiary care unit for glaucoma treatment. Twenty-four ocular hypertension and 64 open-angle glaucoma patients not under treatment. The water-drinking test was performed in 2 consecutive days by the same examiners in patients not under treatment. Reproducibility was assessed using the intraclass correlation coefficient. Peak and fluctuation of intraocular pressure obtained with the water-drinking test were analysed for reproducibility. Eighty-eight eyes from 24 ocular hypertension and 64 open-angle glaucoma patients not under treatment were evaluated. Test and retest intraocular pressure peak values were 28.38 ± 4.64 and 28.38 ± 4.56 mmHg, respectively (P = 1.00). Test and retest intraocular pressure fluctuation values were 5.75 ± 3.9 and 4.99 ± 2.7 mmHg, respectively (P = 0.06). Based on intraclass coefficient, reproducibility was excellent for peak intraocular pressure (intraclass correlation coefficient = 0.79) and fair for intraocular pressure fluctuation (intraclass correlation coefficient = 0.37). Intraocular pressure peaks detected during the water-drinking test presented excellent reproducibility, whereas the reproducibility of fluctuation was considered fair. © 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

  3. Removing obstacles for pavement cost reduction by examining early age opening requirements : material properties.

    DOT National Transportation Integrated Search

    2015-08-01

    The risk of cracking in a concrete pavement that is opened to traffic at early ages is related to the maximum tensile stress, , that : develops in the pavement and its relationship to the measured, age dependent, flexural strength of a beam, fr . T...

  4. Size of the lower third molar space in relation to age in Serbian population.

    PubMed

    Zelić, Ksenija; Nedeljković, Nenad

    2013-10-01

    It is considered that the shortage of space is the major cause of the third molar impaction. The aim of this study was to establish the frequency of insufficient lower third molar eruption space in Serbian population, to question the differences in this frequency in the subjects of different age, to determine the influence of the lower third molar space (retromolar space) size on third molar eruption, and to investigate a possible correlation between the size of gonial angle and the space/third molar width ratio. Digital orthopantomograms were taken from 93 patients divided into two groups: early adult (16-18 years of age) and adult (18-26) patients. Retromolar space, mesiodistal third molar crown width, gonial angle and eruption levels were measured. The space/third molar width in early adult subjects was smaller (p < 0.0001) and insufficient space was significantly more frequent (p = 0.0003) than in adult patients. Considerably more third molars erupted in case of enough space in both age groups (p < 0.0001). There was no difference between the means of gonial angle size in relations to the available space. The retromolar space/third molar width ratio is more favorable in adult subjects. Gonial angle is not in correlation with the retromolar space/third molar width ratio.

  5. Transcorneal Electrical Stimulation Therapy for Retinal Disease

    ClinicalTrials.gov

    2012-05-03

    Retinitis Pigmentosa; Macula Off; Primary Open Angle Glaucoma; Hereditary Macular Degeneration; Treated Retina Detachment; Retinal Artery Occlusion; Retinal Vein Occlusion; Non-Arthritic-Anterior-Ischemic Optic-Neuropathy; Hereditary Autosomal Dominant Optic Atrophy; Dry Age Related Macular Degeneration; Ischemic Macula Edema

  6. Kinematics of reflections in subsurface offset and angle-domain image gathers

    NASA Astrophysics Data System (ADS)

    Dafni, Raanan; Symes, William W.

    2018-05-01

    Seismic migration in the angle-domain generates multiple images of the earth's interior in which reflection takes place at different scattering-angles. Mechanically, the angle-dependent reflection is restricted to happen instantaneously and at a fixed point in space: Incident wave hits a discontinuity in the subsurface media and instantly generates a scattered wave at the same common point of interaction. Alternatively, the angle-domain image may be associated with space-shift (regarded as subsurface offset) extended migration that artificially splits the reflection geometry. Meaning that, incident and scattered waves interact at some offset distance. The geometric differences between the two approaches amount to a contradictory angle-domain behaviour, and unlike kinematic description. We present a phase space depiction of migration methods extended by the peculiar subsurface offset split and stress its profound dissimilarity. In spite of being in radical contradiction with the general physics, the subsurface offset reveals a link to some valuable angle-domain quantities, via post-migration transformations. The angle quantities are indicated by the direction normal to the subsurface offset extended image. They specifically define the local dip and scattering angles if the velocity at the split reflection coordinates is the same for incident and scattered wave pairs. Otherwise, the reflector normal is not a bisector of the opening angle, but of the corresponding slowness vectors. This evidence, together with the distinguished geometry configuration, fundamentally differentiates the angle-domain decomposition based on the subsurface offset split from the conventional decomposition at a common reflection point. An asymptotic simulation of angle-domain moveout curves in layered media exposes the notion of split versus common reflection point geometry. Traveltime inversion methods that involve the subsurface offset extended migration must accommodate the split geometry in the inversion scheme for a robust and successful convergence at the optimal velocity model.

  7. Comparison of factors associated with occludable angle between american Caucasians and ethnic Chinese.

    PubMed

    Wang, Ye Elaine; Li, Yingjie; Wang, Dandan; He, Mingguang; Lin, Shan

    2013-11-21

    To determine if factors associated with gonioscopy-determined occludable angle among American Caucasians are similar to those found in ethnic Chinese. This is a prospective cross-sectional study with 120 American Caucasian, 116 American Chinese, and 116 mainland Chinese subjects. All three groups were matched for sex and age (40-80 years). Gonioscopy was performed for each subject (occludable angles = posterior trabecular meshwork not visible for ≥2 quadrants). Anterior segment optical coherence tomography and customized software was used to measure anterior segment biometry and iris parameters, including anterior chamber depth/width (ACD, ACW), lens vault (LV), and iris thickness/area/curvature. In both Chinese and Caucasians, eyes with occludable angles had smaller ACD and ACW, and larger LV and iris curvature than eyes with open angles (all P < 0.005). Chinese eyes had smaller ACD and ACW than Caucasian eyes (both P < 0.01) in the occludable angle cohort. Iris characteristics did not differ significantly between Chinese and Caucasians in the occludable angle cohort. Based on multivariate logistic regression, gonioscopy-determined occludable angle was significantly associated with LV, iris area, and sex (all P < 0.03) in Chinese; and with LV, ACD, iris thickness, age, and sex (all P < 0.04) in Caucasians. Several factors associated with occludable angle differed between Caucasians and Chinese, suggesting potentially different mechanisms in occludable angle development in the two racial groups. This is the first study to demonstrate that lens vault is an important anterior segment optical coherence tomography parameter in the screening for angle closure in Caucasians. In addition, iris thickness was a significant predictor for occludable angles in Caucasians but was not in ethnic Chinese.

  8. Comparison of Factors Associated With Occludable Angle Between American Caucasians and Ethnic Chinese

    PubMed Central

    Wang, Ye Elaine; Li, Yingjie; Wang, Dandan; He, Mingguang; Lin, Shan

    2013-01-01

    Purpose. To determine if factors associated with gonioscopy-determined occludable angle among American Caucasians are similar to those found in ethnic Chinese. Methods. This is a prospective cross-sectional study with 120 American Caucasian, 116 American Chinese, and 116 mainland Chinese subjects. All three groups were matched for sex and age (40–80 years). Gonioscopy was performed for each subject (occludable angles = posterior trabecular meshwork not visible for ≥2 quadrants). Anterior segment optical coherence tomography and customized software was used to measure anterior segment biometry and iris parameters, including anterior chamber depth/width (ACD, ACW), lens vault (LV), and iris thickness/area/curvature. Results. In both Chinese and Caucasians, eyes with occludable angles had smaller ACD and ACW, and larger LV and iris curvature than eyes with open angles (all P < 0.005). Chinese eyes had smaller ACD and ACW than Caucasian eyes (both P < 0.01) in the occludable angle cohort. Iris characteristics did not differ significantly between Chinese and Caucasians in the occludable angle cohort. Based on multivariate logistic regression, gonioscopy-determined occludable angle was significantly associated with LV, iris area, and sex (all P < 0.03) in Chinese; and with LV, ACD, iris thickness, age, and sex (all P < 0.04) in Caucasians. Conclusions. Several factors associated with occludable angle differed between Caucasians and Chinese, suggesting potentially different mechanisms in occludable angle development in the two racial groups. This is the first study to demonstrate that lens vault is an important anterior segment optical coherence tomography parameter in the screening for angle closure in Caucasians. In addition, iris thickness was a significant predictor for occludable angles in Caucasians but was not in ethnic Chinese. PMID:24168992

  9. Passive Capture Joint with Three Degrees of Freedom

    NASA Technical Reports Server (NTRS)

    Cloyd, Richard A. (Inventor); Weddendorf, Bruce (Inventor)

    2001-01-01

    A passive capture joint with three degrees of freedom is presented wherein two structural elements are joined together solely by moving the two elements into position, and which when joined together have rotation in all three axes. The inventive apparatus is comprised of two halves: (1) a joint ball mounted on a stem as in a common trailer hitch, and; (2) a socket. The socket consists of a base having an exterior wall and forming an interior chamber, the chamber having a top end and a bottom end, and an interior wall. The chamber is open at the top end, and forms a spherical cup at the bottom end. The socket base's interior chamber is sized to accept the joint ball. The base also forms at least one bore at an acute angle away from the interior chamber's open end. The bores have a first opening in the interior wall of the chamber, and a second opening in the exterior wall of the base. Retaining balls sized to fit within the bores, but to only partially pass through the first opening, are moveably housed within the bores. The retaining balls are moveably held in the first opening by a compression spring housed in the bore. As the joint ball is inserted in the chamber it forces the retaining balls back into the bore until the equator of the joint ball passes. Because the bore is at an acute angle to the chamber the joint ball cannot exit the chamber without the joint being unlocked. The joint is unlocked by rotating a locking ring which encircles the base and covers the second opening. The locking ring has a radial slot for each retaining ball, disposed angularly from the base, and sized to allow passage of the retaining ball in the radial direction when the locking ring is rotated to align the radial slot with the second opening.

  10. The importance of early operative treatment in open fractures of the fingers.

    PubMed

    Ng, Tim; Unadkat, Jignesh; Bilonick, Richard A; Wollstein, Ronit

    2014-04-01

    Current guidelines suggest early surgical treatment of open fractures. This rule in open hand fractures is not well supported and may be practically difficult to observe. Furthermore, desirable washout can be obtained in the emergency department (ED). The purpose of this study was to determine the importance of early surgery in our institution. Seventy patients with open fractures of the hand were retrospectively reviewed for demographics, fracture characteristics, and complications. Statistical analysis included univariate analysis, Fisher exact test, and Akaike information criterion. Intravenous antibiotics were administered early in 53 (75.7%) patients. Mean (SD) time to surgery was 2.3 (134.9) hours. The infection rate was 11.4%. No significant relationship was found between fracture type, finger involved, hand dominance, comorbidities, and infection. Antibiotic administration was significantly related to infection (P = 0.007), whereas time to surgery was not (P = 0.33). Age was weakly related to infection (P = 0.08). Administration of intravenous antibiotics in the ED was the most significant factor in preventing infection, whereas the time to operation was not significant. Because a thorough washout and debridement can be performed on open hand fractures in the ED due to the ability to provide adequate anesthesia, the actual time to surgery may possibly be delayed without increasing the risk of infection. Future prospective studies may allow for better guidelines for the treatment of open hand fractures.

  11. Development of a software package for solid-angle calculations using the Monte Carlo method

    NASA Astrophysics Data System (ADS)

    Zhang, Jie; Chen, Xiulian; Zhang, Changsheng; Li, Gang; Xu, Jiayun; Sun, Guangai

    2014-02-01

    Solid-angle calculations play an important role in the absolute calibration of radioactivity measurement systems and in the determination of the activity of radioactive sources, which are often complicated. In the present paper, a software package is developed to provide a convenient tool for solid-angle calculations in nuclear physics. The proposed software calculates solid angles using the Monte Carlo method, in which a new type of variance reduction technique was integrated. The package, developed under the environment of Microsoft Foundation Classes (MFC) in Microsoft Visual C++, has a graphical user interface, in which, the visualization function is integrated in conjunction with OpenGL. One advantage of the proposed software package is that it can calculate the solid angle subtended by a detector with different geometric shapes (e.g., cylinder, square prism, regular triangular prism or regular hexagonal prism) to a point, circular or cylindrical source without any difficulty. The results obtained from the proposed software package were compared with those obtained from previous studies and calculated using Geant4. It shows that the proposed software package can produce accurate solid-angle values with a greater computation speed than Geant4.

  12. Tracing the Angular Dependence of the CGM

    NASA Astrophysics Data System (ADS)

    Nattinger, Michael; Christensen, Charlotte

    2017-01-01

    The circumgalactic media (CGM) is enriched with metals through a process called the baryon cycle, which may play a significant role in the regulation of star formation. While the relationship between the CGM’s baryonic makeup and impact parameter is well documented, the relationship between the baryonic distribution of the CGM and the azimuthal angle out of the plane of the galaxy remains an open question. We investigated the angular distribution of baryons in the CGM by creating mock-absorption line spectra for a high-resolution simulation of a Milky Way-like galaxy at redshift zero. By comparison with data from the Cosmic Origins Spectrograph-Halos survey, we determined that our equivalent widths of HI, MgII, CIII, SiII, and SiIII are consistent with observations. Using our data, we found that low ionization state material is more prevalent at low azimuthal angles and that high ionization state material is more prevalent at high angles within the virial radius. We attributed this increased ionization to higher temperatures at high angles. We also found that the highest metallicity levels appear at high and low azimuthal angles, with lower metallicities at middle angles. This evidence supports the recycled accretion model of CGM baryon flow.

  13. Simulation study of MEMS piezoelectric vibration energy harvester based on c-axis tilted AlN thin film for performance improvement

    NASA Astrophysics Data System (ADS)

    Kong, Lingfeng; Zhang, Jinhui; Wang, Huiyuan; Ma, Shenglin; Li, Fang; Wang, Qing-Ming; Qin, Lifeng

    2016-12-01

    In this paper, a MEMS piezoelectric cantilevered vibration energy harvester based on c-axis tilted AlN thin film is investigated. Based on basic piezoelectric equations and static analysis of cantilever beam, the equations for generated energy (E) and open circuit voltage (Vo) were derived, and simulations were carried out to study the effects of geometry parameters and c-axis tilted angle. Results show that E and Vo of energy harvesters are greatly dependent on c-axis tilted angle and geometry parameters, while the coupling between c-axis tilted angle and geometry parameters is not strong. For a given structure size, E and Vo can be almost simultaneously improved by controlling c-axis tilted angle; compared with the case of normal c-axis angle, E with optimal c-axis tilted angle can be amplified by more than 3 times, and the Vo is amplified by about 2 times. E or Vo could be further improved by geometry parameters, while there is trade-off between them. These results can be used for the design and application of piezoelectric cantilevered vibration energy harvester.

  14. Anatomical features of skull base and oral cavity: a pilot study to determine the accessibility of the sella by transoral robotic-assisted surgery.

    PubMed

    Amelot, Aymeric; Trunet, Stephanie; Degos, Vincent; André, Olivier; Dionnet, Aurore; Cornu, Philippe; Hans, Stéphane; Chauvet, Dorian

    2015-10-01

    The role of transoral robotic surgery (TORS) in the skull base emerges and represents the natural progression toward miniinvasive resections in confined spaces. The accessibility of the sella via TORS has been recently described on fresh human cadavers. An anatomic study is mandatory to know if this approach would be feasible in the majority of patients regardless of their oral morphological features. From 30 skull base CT scans from patients who were asked to open their mouth as wide as they can, we measured specific dimensions of the oral cavity and the skull base, such as length of the palate, mouth opening and distance from the sella to the palate. All data were acquired on a sagittal midline plane and on a 25° rotation plane, which simulated the axis of the robotic instruments. Looking at the projection of the dental palatine line on the sella, we studied possible predictive factors of sellar accessibility and tried to bring objective data for surgical feasibility. We also proposed an angle α to study the working angle at the skull base. We observed that the maximal mouth opening was a good predictive factor of sellar accessibility by TORS (p < 0.05). The mouth aperture threshold value for a good sensitivity, over 80 %, was comparable to the mean value of mouth opening in our series, 38.9 and 39.4 mm respectively. Moreover, we showed a statistically significant increase of the working angle α at the skull base comparing the lateral access to the midline one (p < 0.05). This seemed to quantitatively demonstrate that the robotic arms placed at the labial commissure of the mouth can reach the sella. From these anatomical features and previous cadaveric dissections, we assume that TORS may be feasible on a majority of patients to remove pituitary adenomas.

  15. Opening-wedge high tibial osteotomy with a locked low-profile plate: surgical technique.

    PubMed

    Kolb, Werner; Guhlmann, Hanno; Windisch, Christoph; Koller, Heiko; Grützner, Paul; Kolb, Klaus

    2010-09-01

    High tibial osteotomy has been recognized as a beneficial treatment for osteoarthritis of the medial compartment of the knee. The purpose of this prospective study was to assess the short-term results of opening-wedge high tibial osteotomies with locked plate fixation. From September 2002 to November 2005, fifty-one consecutive medial opening-wedge high tibial osteotomies were performed. The mean age of the patients at the time of the index operation was forty-nine years. The preoperative and postoperative factors analyzed included the grade of arthritis of the tibiofemoral compartment (the Ahlbäck radiographic grade), the anatomic tibiofemoral angle, patellar height, the Hospital for Special Surgery rating system score, and the Lysholm and Gillquist knee score. Postoperatively, one superficial wound infection occurred. Fifty of the fifty-one osteotomies healed after an average period of 12.9 weeks (range, eight to sixteen weeks) without bone grafts. A nonunion developed in a sixty-two-year-old patient who was a cigarette smoker. The average postoperative tibiofemoral angle was 9° of valgus. Forty-nine patients were followed for a mean of fifty-two months. The average score on the Hospital for Special Surgery rating system was 86 points at the time of the most recent follow-up. The rating was excellent in twenty-eight patients (57%), good in twelve (24%), fair in four (8%), and poor in five (10%). The average score on the Lysholm and Gillquist knee-scoring scale was 83 points. According to these scores, the outcome was excellent in nine patients (18%), good in thirty-one (63%), fair in three (6%), and poor in six (12%). Four knees failed after an average of thirty-six months. Our results suggest that an opening-wedge high tibial osteotomy with locked plate fixation allows a correct valgus angle to be achieved with good short-term results.

  16. Comparison of clinical results between novel percutaneous pedicle screw and traditional open pedicle screw fixation for thoracolumbar fractures without neurological deficit.

    PubMed

    Yang, Ming; Zhao, Qinpeng; Hao, Dingjun; Chang, Zhen; Liu, Shichang; Yin, Xinhua

    2018-06-16

    To compare the efficacy and safety of novel percutaneous minimally invasive pedicle screw fixation and traditional open surgery for thoracolumbar fractures without neurological deficit. Sixty adult patients with single thoracolumbar fracture between June 2014 and June 2016 were recruited in this study, randomly divided into open fixation group (group A) or minimally invasive percutaneous fixation group (group B). Clinical and surgical evaluation including surgery time, blood losses, radiation times, hospital stay, and complication were performed. The two groups of patients with pre-operative and last follow-up anterior height ratio of fracture vertebral, Cobb angle of fracture vertebral, and VAS score of back pain were compared. All patients completed valid follow-ups, with an average time period of 15.4 months (12-26 months). Group B achieved much better results in time of operation, intra-operative blood loss, and length of stay than group A (P < 0.05). Group A was significantly better than group B in the times of radiation (P < 0.05). The VAS score was significantly lower in group B than in group A at three days after the operation (P < 0.05). There were no significant differences between the two groups in the anterior height ratio of fracture vertebral, Cobb angle, and VAS score in the last follow-up (P > 0.05). No injured nerve or other severe complications occurred in both groups; one of the patients from group A had back and loin pain lasting for about one month, which resolved after analgesia and functional training. There was no significant difference between the two groups in incidence of complications. Novel percutaneous pedicle screws with angle reset function can achieve the same effect as traditional open pedicle screw fixation in the treatment of thoracolumbar fractures without nerve injuries. Percutaneous minimally invasive pedicle screw fixation has the characteristics of shorter operative time, less bleeding, and less pain, but it needs more radiation times.

  17. Hover and wind-tunnel testing of shrouded rotors for improved micro air vehicle design

    NASA Astrophysics Data System (ADS)

    Pereira, Jason L.

    The shrouded-rotor configuration has emerged as the most popular choice for rotary-wing Micro Air Vehicles (MAVs), because of the inherent safety of the design and the potential for significant performance improvements. However, traditional design philosophies based on experience with large-scale ducted propellers may not apply to the low-Reynolds-number (˜20,000) regime in which MAVs operate. An experimental investigation of the effects of varying the shroud profile shape on the performance of MAV-scale shrouded rotors has therefore been conducted. Hover tests were performed on seventeen models with a nominal rotor diameter of 16 cm (6.3 in) and various values of diffuser expansion angle, diffuser length, inlet lip radius and blade tip clearance, at various rotor collective angles. Compared to the baseline open rotor, the shrouded rotors showed increases in thrust by up to 94%, at the same power consumption, or reductions in power by up to 62% at the same thrust. These improvements surpass those predicted by momentum theory, due to the additional effect of the shrouds in reducing the non-ideal power losses of the rotor. Increasing the lip radius and decreasing the blade tip clearance caused performance to improve, while optimal values of diffuser angle and length were found to be 10 and 50% of the shroud throat diameter, respectively. With the exception of the lip radius, the effects of changing any of the shrouded-rotor parameters on performance became more pronounced as the values of the other parameters were changed to degrade performance. Measurements were also made of the wake velocity profiles and the shroud surface pressure distributions. The uniformity of the wake was improved by the presence of the shrouds and by decreasing the blade tip clearance, resulting in lower induced power losses. For high net shroud thrust, a favorable pressure distribution over the inlet was seen to be more important than in the diffuser. Strong suction pressures were observed above the blade-passage region on the inlet surface; taking advantage of this phenomenon could enable further increases in thrust. However, trade studies showed that, for a given overall aircraft size limitation, and ignoring considerations of the safety benefits of a shroud, a larger-diameter open rotor is more likely to give better performance than a smaller-diameter shrouded rotor. The open rotor and a single shrouded-rotor model were subsequently tested at a single collective in translational flight, at angles of attack from 0° (axial flow) to 90° (edgewise flow), and at various advance ratios. In axial flow, the net thrust and the power consumption of the shrouded rotor were lower than those of the open rotor. In edgewise flow, the shrouded rotor produced greater thrust than the open rotor, while consuming less power. Measurements of the shroud surface pressure distributions illustrated the extreme longitudinal asymmetry of the flow around the shroud, with consequent pitch moments much greater than those exerted on the open rotor. Except at low airspeeds and high angles of attack, the static pressure in the wake did not reach ambient atmospheric values at the diffuser exit plane; this challenges the validity of the fundamental assumption of the simple-momentum-theory flow model for short-chord shrouds in translational flight.

  18. Open ocean Internal Waves, Namibia Coast, Africa.

    NASA Image and Video Library

    1990-12-10

    These open ocean Internal Waves were seen off the Namibia Coast, Africa (23.0S, 14.0E). The periodic and regularly spaced sets of internal waves most likely coincide with tidal periods about 12 hours apart. The wave length (distance from crest to crest) varies between 1.5 and 5.0 miles and the crest lengths stretch across and beyond the distance of the photo. The waves are intersecting the Namibia coastline at about a 30 degree angle.

  19. Open ocean Internal Waves, Namibia Coast, Africa.

    NASA Technical Reports Server (NTRS)

    1990-01-01

    These open ocean Internal Waves were seen off the Namibia Coast, Africa (23.0S, 14.0E). The periodic and regularly spaced sets of internal waves most likely coincide with tidal periods about 12 hours apart. The wave length (distance from crest to crest) varies between 1.5 and 5.0 miles and the crest lengths stretch across and beyond the distance of the photo. The waves are intersecting the Namibia coastline at about a 30 degree angle.

  20. CALUTRON RECEIVER

    DOEpatents

    Brunk, W.O.

    1959-09-29

    A description is given for an improved calutron receiver having a face plate lying at an angle to the direction of the entering ion beams but having an opening, the plane of which is substantially perpendicular to that of the entering ion beams. By so positioning the opening in the receiver, the effective area through which the desired material may enter the receiver is increased, and at the same time the effective area through which containattng material may enter the receiver is reduced.

  1. John F. Kennedy Space Center's Wireless Hang Angle Instrumentation System

    NASA Technical Reports Server (NTRS)

    Kohler, Jeff

    2009-01-01

    The technology is a high-precision, wireless inclinometer. The system was designed for monitoring the suspension angle of the Orbiter vehicle during loading onto the Solid Rocket Boosters of the Space Shuttle. Originally, operators manually measured the alignment of the Orbiter with a hand-held inclinometer on a nonrigid surface. The measurement was open to interpretation by the loader. If the Orbiter is misaligned, it can crush ball joints and delay the loading while repairs are made. With this system, the Orbiter can be loaded without damage and without manual measurement.

  2. The very low angle detector for high-energy inelastic neutron scattering on the VESUVIO spectrometer

    NASA Astrophysics Data System (ADS)

    Perelli Cippo, E.; Gorini, G.; Tardocchi, M.; Pietropaolo, A.; Andreani, C.; Senesi, R.; Rhodes, N. J.; Schooneveld, E. M.

    2008-05-01

    The Very Low Angle Detector (VLAD) bank has been installed on the VESUVIO spectrometer at the ISIS spallation neutron source. The new device allows for high-energy inelastic neutron scattering measurements, at energies above 1 eV, maintaining the wave vector transfer lower than 10Å-1. This opens a still unexplored region of the kinematical (q, ω) space, enabling new and challenging experimental investigations in condensed matter. This paper describes the main instrumental features of the VLAD device, including instrument design, detector response, and calibration procedure.

  3. Planar waveguide nanolaser configured by dye-doped hybrid nanofilm on substrate

    NASA Astrophysics Data System (ADS)

    Tikhonov, E. A.; Yashchuk, V. P.; Telbiz, G. M.

    2018-04-01

    Dye-doped hybrid silicate/titanium nanofilms on the glass substrate structures of asymmetrical waveguides were studied by way of laser systems. The threshold, spatial and spectral features of the laser oscillation of genuine and hollow waveguides were determined. The pattern of stimulated radiation included two concurrent processes: single-mode waveguide lasing and lateral small divergence emission. Comparison of the open angle of the lateral beams and grazing angles of the waveguide lasing mode provides an insight into the effect of leaky mode emission followed by Lummer-Gehrcke interference.

  4. Experimental investigation into wing span and angle-of-attack effects on sub-scale race car wing/wheel interaction aerodynamics

    NASA Astrophysics Data System (ADS)

    Diasinos, S.; Gatto, A.

    2008-09-01

    This paper details a quantitative 3D investigation using LDA into the interaction aerodynamics on a sub-scale open wheel race car inverted front wing and wheel. Of primary importance to this study was the influence of changing wing angle of attack and span on the resulting near-field and far-field flow characteristics. Results obtained showed that both variables do have a significant influence on the resultant flow-field, particularly on wing vortex and wheel wake development and propagation.

  5. Substrate-Induced Allosteric Change in the Quaternary Structure of the Spermidine N-Acetyltransferase SpeG.

    PubMed

    Filippova, Ekaterina V; Weigand, Steven; Osipiuk, Jerzy; Kiryukhina, Olga; Joachimiak, Andrzej; Anderson, Wayne F

    2015-11-06

    The spermidine N-acetyltransferase SpeG is a dodecameric enzyme that catalyzes the transfer of an acetyl group from acetyl coenzyme A to polyamines such as spermidine and spermine. SpeG has an allosteric polyamine-binding site and acetylating polyamines regulate their intracellular concentrations. The structures of SpeG from Vibrio cholerae in complexes with polyamines and cofactor have been characterized earlier. Here, we present the dodecameric structure of SpeG from V. cholerae in a ligand-free form in three different conformational states: open, intermediate and closed. All structures were crystallized in C2 space group symmetry and contain six monomers in the asymmetric unit cell. Two hexamers related by crystallographic 2-fold symmetry form the SpeG dodecamer. The open and intermediate states have a unique open dodecameric ring. This SpeG dodecamer is asymmetric except for the one 2-fold axis and is unlike any known dodecameric structure. Using a fluorescence thermal shift assay, size-exclusion chromatography with multi-angle light scattering, small-angle X-ray scattering analysis, negative-stain electron microscopy and structural analysis, we demonstrate that this unique open dodecameric state exists in solution. Our combined results indicate that polyamines trigger conformational changes and induce the symmetric closed dodecameric state of the protein when they bind to their allosteric sites. Copyright © 2015. Published by Elsevier Ltd.

  6. Substrate-induced allosteric change in the quaternary structure of the spermidine N-acetyltransferase SpeG

    DOE PAGES

    Filippova, Ekaterina V.; Weigand, Steven J.; Osipiuk, Jerzy; ...

    2015-09-26

    The spermidine N-acetyltransferase SpeG is a dodecameric enzyme that catalyzes the transfer of an acetyl group from acetyl coenzyme A to polyamines such as spermidine and spermine. SpeG has an allosteric polyamine-binding site and acetylating polyamines regulate their intracellular concentrations. The structures of SpeG from Vibrio cholerae in complexes with polyamines and cofactor have been characterized earlier. Here, we present the dodecameric structure of SpeG from V. cholerae in a ligand-free form in three different conformational states: open, intermediate and closed. All structures were crystallized in C2 space group symmetry and contain six monomers in the asymmetric unit cell. Twomore » hexamers related by crystallographic 2-fold symmetry form the SpeG dodecamer. The open and intermediate states have a unique open dodecameric ring. This SpeG dodecamer is asymmetric except for the one 2-fold axis and is unlike any known dodecameric structure. Using a fluorescence thermal shift assay, size-exclusion chromatography with multi-angle light scattering, small-angle X-ray scattering analysis, negative-stain electron microscopy and structural analysis, we demonstrate that this unique open dodecameric state exists in solution. As a result, our combined results indicate that polyamines trigger conformational changes and induce the symmetric closed dodecameric state of the protein when they bind to their allosteric sites.« less

  7. Patterns of folding and fold interference in oblique contraction of layered rocks of the inverted Cobar Basin, Australia

    NASA Astrophysics Data System (ADS)

    Smith, J. V.; Marshall, B.

    1992-12-01

    The inverted Cobar Basin, within the Lachlan Fold Belt of New South Wales, Australia, comprises a mid-Palaeozoic cover sequence, originally deposited in a NNW-trending basin. The pattern of F 1 folding in the layered cover rocks changes from east to west; from tight well-cleaved folds parallel to the NNW-trending basin margin on the east, to open poorly cleaved en echelon folds at about 35° to the margin, further to the west. The change in fold trend and strain intensity has been repeatedly ascribed to the differing behaviour of discrete zones, decoupled across a north-trending strike-slip fault boundary. New field data show that the changes in orientation and strain intensity of F 1 structures are progressively developed, that an abrupt boundary between discrete zones cannot be substantiated, and that interpretations involving decoupled blocks are not supported by the evidence. Conversely, the data require coherent behaviour across the basin, such that the overall pattern of F 1 folding must be explained by strain compatible processes. This new interpretation of the F 1 deformation pattern has been modelled and quantitatively analysed. Theoretical predictions of the orientation of structures in unlayered isotropic material undergoing oblique contraction are inapplicable to layered anisotropic material. The style of deformation in layered material will reflect the interaction of the bulk strain pattern due to convergence together with the influence of the layering anisotropy. The orientations of the finite strain axes inferred from the folding need not match those of the bulk deformation; the amount of strain recorded by folding may be unrepresentative of that developed in the deformed tract. Oblique contraction at a range of convergence angles was simulated by models employing layers of wet tissue paper. Quantitative analysis of the strain patterns in this layered anisotropic material showed consistent departures from the theoretical predictions for isotropic material. The orientations of the principal finite horizontal extension proximal to the margin yielded higher convergence angles than those which were imposed; the orientations distal from the margin yielded substantially lower apparent convergence angles. This is because the layering anisotropy results in tight folds dissipating the normal component of the oblique convergence vector close to the margin. Whereas more open structures further from the margin show orientations controlled by the progressively more dominant shear component of the vergence vector. Modelling of D 1 the Cobar Basin shows that the F 1 pattern is consistent with dextral oblique convergence at 60° to the eastern margin of the basin. The deformation patterns, in both the model and the Cobar Basin, yield higher proximal and substantially lower distal apparent convergence angles. This is as expected from theoretical considerations and quantitative analysis of oblique contraction over a range of convergence angles. The rheological anisotropy of the cover sequence of the basin is replicated by that of the layered wet tissue paper. Wet-tissue modelling of the superposition of the second period of deformation (D 2) on F 1 demonstrates the way in which the tightness and orientation of early folds influence the type of fold interference pattern. At the eastern margin of the Cobar Basin, where D 1 was most intense, this resulted in major swings of the strike of bedding and cleavage, and of the trend of F 1 folds. Further west, open basin and dome patterns developed where D 1 was least intense. Principles developed in relation to the inversion of the Cobar Basin, are equally applicable to other basins in which layered cover rocks have undergone inversion by oblique contraction. Many basins in the Lachlan Fold Belt and in general would fall within this category.

  8. Mini-open anterior instrumentation with diaphragm sparing for thoracolumbar idiopathic scoliosis: its technique and clinical results

    PubMed Central

    Zhu, Feng; Wang, Bin; Zhu, Zezhang; Yu, Yang; Sun, Xu; Ma, Weiwei

    2010-01-01

    The traditional method of thoracoabdominal retroperitoneal approach requires dissection of diaphragm which bears potential complications such as postoperatively weakened abdominal breathing and dysfunction of diaphragm. Mini-open anterior instrumentation with diaphragm sparing is designed to minimize the damage to diaphragm and improve cosmesis. This study compared the traditional anterior instrumentation and mini-open anterior instrumentation under the hypothesis that both results in similar surgical outcomes in treating thoracolumbar scoliosis. In Group A, 38 patients with an average age of 16.5 years underwent mini-open anterior instrumentation with diaphragm sparing. The average standing coronal Cobb angle was 56.4° in Group A. Thirty-eight patients with average age of 16.7 years in Group B received traditional open approach. The preoperative average Cobb angle was 55.8° in Group B. The average correction rate of coronal curve was 78% in group A while 75% in group B. No statistical difference between the two groups in terms of coronal curve correction, sagittal profile restoration and estimated blood loss was observed. The operation time was significantly higher in Group A than that in Group B. All patients in the two groups had good healing of incisions without neurological and instrumental complications during minimal 2 year follow-up. In Groups A and B, two patients suffered from pleural effusion, respectively. The wedging of the vertebral discs distal to the lowest fused level occurred in three and four patients in Group A and B, respectively. One case in group B was found to be suspicious pseudoarthrosis without loss of correction. Mini-open anterior instrumentation with diaphragm sparing could minimize the surgical invasion as well as achieve similar clinical outcomes compared with classical anterior approach. PMID:21181213

  9. Clinical and Radiological Outcomes Comparing Percutaneous Chevron-Akin Osteotomies vs Open Scarf-Akin Osteotomies for Hallux Valgus.

    PubMed

    Lai, Mun Chun; Rikhraj, Inderjeet Singh; Woo, Yew Lok; Yeo, William; Ng, Yung Chuan Sean; Koo, Kevin

    2018-03-01

    Minimally invasive surgeries have gained popularity due to less soft tissue trauma and better wound healing. To date, limited studies have compared the outcomes of percutaneous and open osteotomies. This study aims to investigate the clinical and radiological outcomes of percutaneous chevron-Akin osteotomies vs open scarf-Akin osteotomies at 24-month follow-up. We reviewed a prospectively collected database in a tertiary hospital hallux valgus registry. Twenty-nine feet that underwent a percutaneous technique were matched to 58 feet that underwent open scarf and Akin osteotomies. Clinical outcome measures assessed included visual analog scale (VAS) scores, American Orthopaedic Foot & Ankle Society Hallux Metatarsophalangeal-Interphalangeal score (AOFAS Hallux MTP-IP), and Short Form 36 (SF-36) Health Survey. Radiological outcomes included hallux valgus angle (HVA) and intermetatarsal angle (IMA). All patients were prospectively followed up at 6 and 24 months. Both groups showed comparable clinical and radiological outcomes at the 24-month follow-up. However, the percutaneous group demonstrated less pain in the perioperative period ( P < .001). There were significant differences in the change in HVA between the groups but comparable radiological outcomes in IMA at the 24-month follow-up. The percutaneous group demonstrated shorter length of operation ( P < .001). There were no complications in the percutaneous group but 3 wound complications in the open group. We conclude that clinical and radiological outcomes of third-generation percutaneous chevron-Akin osteotomies were comparable with open scarf and Akin osteotomies at 24 months but with significantly less perioperative pain, shorter length of operation, and less risk of wound complications. Level III, retrospective comparative series.

  10. Proximal Opening Wedge Osteotomy Provides Satisfactory Midterm Results With a Low Complication Rate.

    PubMed

    Oravakangas, Rami; Leppilahti, Juhana; Laine, Vesa; Niinimäki, Tuukka

    2016-01-01

    Hallux valgus is one of the most common foot deformities. Proximal opening wedge osteotomy is used for the treatment of moderate and severe hallux valgus with metatarsus primus varus. However, hypermobility of the first tarsometatarsal joint can compromise the results of the operation, and a paucity of midterm results are available regarding proximal open wedge osteotomy surgery. The aim of the present study was to assess the midterm results of proximal open wedge osteotomy in a consecutive series of patients with severe hallux valgus. Thirty-one consecutive adult patients (35 feet) with severe hallux valgus underwent proximal open wedge osteotomy. Twenty patients (35.5%) and 23 feet (34.3%) were available for the final follow-up examination. The mean follow-up duration was 5.8 (range 4.6 to 7.0) years. The radiologic measurements and American Orthopaedic Foot and Ankle Society hallux-metatarsophalangeal-interphalangeal scores were recorded pre- and postoperatively, and subjective questionnaires were completed and foot scan analyses performed at the end of the follow-up period. The mean hallux valgus angle decreased from 38° to 23°, and the mean intermetatarsal angle correction decreased from 17° to 10°. The mean improvement in the American Orthopaedic Foot and Ankle Society hallux metatarsophalangeal-interphalangeal score increased from 52 to 84. Two feet (5.7%) required repeat surgery because of recurrent hallux valgus. No nonunions were identified. Proximal open wedge osteotomy provided satisfactory midterm results in the treatment of severe hallux valgus, with a low complication rate. The potential instability of the first tarsometatarsal joint does not seem to jeopardize the midterm results of the operation. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Poster - 23: Dosimetric Characterization and Transferability of an Accessory Mounted Mini-Beam Collimator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, William; Crewson, Cody; Alexander, Andrew

    Objective: The dosimetric characterization of an accessory-mounted mini-beam collimator across three beam matched linear accelerators. Materials and Methods: Percent depth dose and profiles were measured for the open and mini-beam collimated fields. The average beam quality and peak-to-valley dose ratio (PVDR), the ratio of average peak dose to average valley dose, were obtained from these measurements. The open field relative output and the mini-beam collimator factor, the ratio of the mini-beam dose to open field dose at the beam center, were measured for square fields of side 2, 3, 4, and 5 cm. Mini-beam output as a function of collimatormore » inclination angle relative to the central axis was also investigated. Results and Discussion: Beam quality for both the open and mini-beam collimated fields agreed across all linacs to within ±1.0%. The PVDR was found to vary by up to ±6.6% from the mean. For the 2, 3, and 4 cm fields the average open field relative output with respect to the 5 cm field was 0.874±0.4%, 0.921±0.3%, and 0.962±0.1%. The average collimator factors were 0.450±3.9%, 0.443±3.9%, 0.438±3.9%, and 0.434±3.9%. A decrease in collimator factor greater than 7% was found for an inclination angle change of 0.09°. Conclusion: The mini-beam collimator has revealed a difference between the three linacs not apparent in the open field data, yet transferability can still be attained through thorough dosimetric characterization.« less

  12. Broadband and polarization reflectors in the lookdown, Selene vomer.

    PubMed

    Zhao, Shulei; Brady, Parrish Clawson; Gao, Meng; Etheredge, Robert Ian; Kattawar, George W; Cummings, Molly E

    2015-03-06

    Predator evasion in the open ocean is difficult because there are no objects to hide behind. The silvery surface of fish plays an important role in open water camouflage. Various models have been proposed to account for the broadband reflectance by the fish skin that involve one-dimensional variations in the arrangement of guanine crystal reflectors, yet the three-dimensional organization of these guanine platelets have not been well characterized. Here, we report the three-dimensional organization and the optical properties of integumentary guanine platelets in a silvery marine fish, the lookdown (Selene vomer). Our structural analysis and computational modelling show that stacks of guanine platelets with random yaw angles in the fish skin produce broadband reflectance via colour mixing. Optical axes of the guanine platelets and the collagen layer are aligned closely and provide bulk birefringence properties that influence the polarization reflectance by the skin. These data demonstrate how the lookdown preserves or alters polarization states at different incident polarization angles. These optical properties resulted from the organization of these guanine platelets and the collagen layer may have implications for open ocean camouflage in varying light fields. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  13. Tilt angle dependence of backscattering enhancements from organ pipe modes of open water-filled cylinders: Measurements and models

    NASA Astrophysics Data System (ADS)

    Osterhoudt, Curtis F.; Marston, Philip L.

    2003-04-01

    A simple target for simulating narrow low-frequency resonances of cylinders is an open metal pipe completely filled with water. We have previously described how the high-Q organ-pipe modes having a pressure node near each end are easily observed in backscattering experiments with small cylinders [C. F. Osterhoudt and P. L. Marston, J. Acoust. Soc. Am. 110, 2773 (2001)]. The resonance occurs because of the strong reflection of internal acoustic waves from the open ends of the pipe [H. Levine and J. Schwinger, Phys. Rev. 73, 383-406 (1948)]. In the present research, the dependence of the backscattering amplitude on the orientation of the cylinder is measured and modeled. The tilt angle dependence is affected by the symmetry of the organ pipe mode. An approximation was also developed for the backscattering amplitude at high Q resonances based on energy conservation, reciprocity, and the optical theorem. While this analysis applies to cylinders suspended in water away from boundaries, the organ-pipe modes studied may be useful for investigating scattering processes for buried or partially buried cylinders. [Research supported in part by ONR.

  14. Rationale for early versus late intervention with arthroscopy for treatment of inflammatory/degenerative temporomandibular joint disorders.

    PubMed

    Israel, Howard A; Behrman, David A; Friedman, Joel M; Silberstein, Jennifer

    2010-11-01

    The goal of this study was to determine if there were differences in outcomes of arthroscopic surgery in patients with inflammatory/degenerative temporomandibular joint (TMJ) disease who underwent early surgical intervention versus late surgical intervention. The study population included 44 consecutive patients who met the criteria for TMJ operative arthroscopy who were divided into early and late intervention groups. The time between the onset of symptoms and the performance of arthroscopy was used to determine entry into the early versus late intervention group. All groups were evaluated for changes in preoperative versus postoperative pain levels based on visual analog scale (VAS) scores and maximum interincisal opening distance. Statistical analyses included the Student t test to determine if there were significant differences between preoperative and postoperative assessments in the early and late intervention groups. The mean time between onset of symptoms in the early intervention group (21 patients) was 5.4 months compared with 33 months in the late intervention group (23 patients). All patient groups had statistically significant decreases in pain and improvement in maximum interincisal opening distance after arthroscopy. The early intervention group had a mean decrease in VAS pain scores of 5.14 compared with the late intervention group with a mean decrease in VAS pain scores of 2.84, and this difference was significant (P = .012). The early intervention group had a mean increase in maximum interincisal opening of 12.38 mm compared with the late intervention group with a mean increase of 7.70. Although statistical significance was not achieved for increases in maximum interincisal opening between the early and late intervention groups (P = .089), the difference between the 2 groups was suggestive of a trend. There were no surgical complications for either group; however, 2 patients in the late intervention group developed persistent chronic neuropathic pain, requiring pain management. TMJ arthroscopy reliably decreased pain and increased the maximum interincisal opening distance in the early and late intervention groups. The early intervention group had better surgical outcomes than the late intervention group. Arthroscopic surgery should be considered early in the management of patients with inflammatory/degenerative TMJ disease. Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Comparison of clinical, radiographic, computed tomographic, and magnetic resonance imaging methods for early prediction of canine hip laxity and dysplasia.

    PubMed

    Ginja, Mário M D; Ferreira, António J; Jesus, Sandra S; Melo-Pinto, Pedro; Bulas-Cruz, José; Orden, Maria A; San-Roman, Fidel; Llorens-Pena, Maria P; Gonzalo-Orden, José M

    2009-01-01

    The purpose of the study was to use two palpation methods (Bardens and Ortolani), a radiographic distraction view, three computed tomography (CT) measurements (dorsolateral subluxation score, the lateral center-edge angle, and acetabular ventroversion angle) and two magnetic resonance (MR) imaging hip studies (synovial fluid and acetabular depth indices) in the early monitoring of hip morphology and laxity in 7-9 week old puppies; and in a follow-up study to compare their accuracy in predicting later hip laxity and dysplasia. The MR imaging study was performed with the dog in dorsal recumbency and the CT study with the animal in a weight-bearing position. There was no association between clinical laxity with later hip laxity or dysplasia. The dorsolateral subluxation score and the lateral center-edge angle were characterized by a weak negative correlation with later radiographic passive hip laxity (-0.26 < r < -0.38, P < 0.05) but its association with hip dysplasia was not significant. There was an association between early radiographic passive hip laxity and synovial fluid index with later passive hip laxity (0.41 < r < 0.55, P < 0.05) and this was significantly different in dysplastic vs. nondysplastic hips (P < 0.05). There was no association between the remaining variables and later hip laxity or dysplasia. The overlapping ranges of early passive hip laxity and synovial fluid index for hip dysplasia grades and the moderate correlations with the later passive hip laxity make the results of these variables unreliable for use in predicting hip laxity and dysplasia susceptibility.

  16. Development of a prototype Open-close positron emission tomography system

    NASA Astrophysics Data System (ADS)

    Yamamoto, Seiichi; Okumura, Satoshi; Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu; Toshito, Toshiyuki; Komori, Masataka; Ogata, Yoshimune; Kato, Katsuhiko; Hatazawa, Jun

    2015-08-01

    We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types of gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image guides were used to arrange the two scintillator blocks at 22.5° so that they can be arranged in a hexadecagonal shape with eight block detectors to simplify the reconstruction algorithm. The detector ring was divided into two halves to realize the open-mode and set on a mechanical stand with which the distance between the two parts can be manually changed. The spatial resolution in the close-mode was 2.4-mm FWHM, and the sensitivity was 1.7% at the center of the field-of-view. In both the close- and open-modes, we made sagittal (y-z plane) projection images between the two halved detector rings. We obtained reconstructed and projection images of 18F-NaF rat studies and proton-irradiated phantom images. These results indicate that our developed Open-close PET is useful for some applications such as proton therapy as well as other applications such as molecular imaging.

  17. Focused Molding Using Adhesive Pads in Mehta Casting for Early-Onset Scoliosis.

    PubMed

    Abraham, Roby; Sponseller, Paul D

    2014-11-01

    Prospective clinical series. To determine the effect of adhesive pads placed over the apex of scoliosis curves on curve correction 1) after the first cast and 2) after the final cast. Early-onset scoliosis is often effectively managed by serial casting. Properly localizing the apex of the molds with the cast in place is challenging. The authors explored the effectiveness of a novel technique: incorporation of adhesive pads placed over the major curve apex before Mehta casting. The 27 patients who received body casts (2000-2013) were divided into 2 groups: those without and with apical adhesive pads (5-6 layers of pads placed on the major curve's apex during casting): non-pad (NP) group (n = 12) and pad (P) group (n = 15), respectively. Groups were compared regarding the percentage of Cobb angle change from the first cast and curve correction to a Cobb angle of <25° with Student t and chi-square tests (significance was p < .05). The mean percentage of major first-cast curve correction was 39% ± 18% and 56% ± 17% in the NP and P groups, respectively. Of the 26 patients out of a cast, 11 (42%) had a Cobb angle of <25°: 3 (25%) and 8 (57%) in the NP and P groups, respectively. The mean differences between the 2 groups in percentage of major curve correction and this Cobb angle correction were significant: p = .023 and .005, respectively. Adhesive pads placed over major curve(s) during Mehta casting were effective in increasing the amount of major curve correction from the first cast for idiopathic early-onset scoliosis and in decreasing curves to <25° at final follow-up. Copyright © 2014 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  18. Open for Business

    ERIC Educational Resources Information Center

    Voyles, Bennett

    2007-01-01

    People know about the Sakai Project (open source course management system); they may even know about Kuali (open source financials). So, what is the next wave in open source software? This article discusses business intelligence (BI) systems. Though open source BI may still be only a rumor in most campus IT departments, some brave early adopters…

  19. Kinematic error magnitude in the single-mass inverted pendulum model of human standing posture.

    PubMed

    Fok, Kai Lon; Lee, Jae; Vette, Albert H; Masani, Kei

    2018-06-01

    Many postural control studies employ a single-mass inverted pendulum model (IPM) to represent the body during standing. However, it is not known to what degree and for what conditions the model's kinematic assumptions are valid. Our first objective was to quantify the IPM error, corresponding to a distance change between the ankle joint and center of mass (COM) during unrestricted, natural, unperturbed standing. A second objective was to quantify the error of having the ankle joint angle represent the COM angle. Eleven young participants completed five standing conditions: quiet standing with eyes open (EO) and closed (EC), voluntarily swaying forward (VSf) and backward (VSb), and freely moving (FR). The modified Helen-Hayes marker model was used to capture the body kinematics. The COM distance changed <0.1% during EO and EC, <0.25% during VSf and VSb, and <1.5% during FR. The ankle angle moderately and positively correlated with the COM angle for EO, EC, and VSf, indicating that temporal features of the ankle angle moderately represent those of the COM angle. However, a considerable offset between the two existed, which needs to be considered when estimating the COM angle using the ankle angle. For VSb and FR, the correlation coefficients were low and/or negative, suggesting that a large error would result from using the ankle angle as an estimate of the COM angle. Insights from this study will be critical for deciding when to use the IPM in postural control research and for interpreting associated results. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Structurally colored films with superhydrophobicity and wide viewing angles based on bumpy melanin-like particles

    NASA Astrophysics Data System (ADS)

    Yi, Bo; Shen, Huifang

    2018-01-01

    Non-iridescent structural colors and lotus effect universally existing in the nature provide a great inspiration for artificially developing angle-independent and high hydrophobic structurally colored films. To this end, a facile strategy is put forward for achieving superhydrophobic structurally colored films with wide viewing angles and high visibility based on bumpy melanin-like polydopamine-coated polystyrene particles. Here, hierarchical and amorphous structures are assembled in a self-driven manner due to particles' protrusive surfaces. The superhydrophobicity of the structurally colored films, with water contact angle up to 151°, is realized by combining the hierarchical surface roughness with a dip-coating process of polydimethylsiloxane-hexane solution, while angle-independence revealed in the films is ascribed to amorphous arrays. In addition, benefited from an essential light-absorbing property and high refractive index of polydopamine, the visibility of as-prepared colored films is fundamentally enhanced. Moreover, the mechanical robustness of the films is considerably boosted by inletting 3-aminopropyltriethoxysilane. This fabrication strategy might provide an opportunity for promoting the open-air application of structurally colored coatings.

Top