Effect of alignment of easy axes on dynamic magnetization of immobilized magnetic nanoparticles
NASA Astrophysics Data System (ADS)
Yoshida, Takashi; Matsugi, Yuki; Tsujimura, Naotaka; Sasayama, Teruyoshi; Enpuku, Keiji; Viereck, Thilo; Schilling, Meinhard; Ludwig, Frank
2017-04-01
In some biomedical applications of magnetic nanoparticles (MNPs), the particles are physically immobilized. In this study, we explore the effect of the alignment of the magnetic easy axes on the dynamic magnetization of immobilized MNPs under an AC excitation field. We prepared three immobilized MNP samples: (1) a sample in which easy axes are randomly oriented, (2) a parallel-aligned sample in which easy axes are parallel to the AC field, and (3) an orthogonally aligned sample in which easy axes are perpendicular to the AC field. First, we show that the parallel-aligned sample has the largest hysteresis in the magnetization curve and the largest harmonic magnetization spectra, followed by the randomly oriented and orthogonally aligned samples. For example, 1.6-fold increase was observed in the area of the hysteresis loop of the parallel-aligned sample compared to that of the randomly oriented sample. To quantitatively discuss the experimental results, we perform a numerical simulation based on a Fokker-Planck equation, in which probability distributions for the directions of the easy axes are taken into account in simulating the prepared MNP samples. We obtained quantitative agreement between experiment and simulation. These results indicate that the dynamic magnetization of immobilized MNPs is significantly affected by the alignment of the easy axes.
A high-throughput semi-automated preparation for filtered synaptoneurosomes.
Murphy, Kathryn M; Balsor, Justin; Beshara, Simon; Siu, Caitlin; Pinto, Joshua G A
2014-09-30
Synaptoneurosomes have become an important tool for studying synaptic proteins. The filtered synaptoneurosomes preparation originally developed by Hollingsworth et al. (1985) is widely used and is an easy method to prepare synaptoneurosomes. The hand processing steps in that preparation, however, are labor intensive and have become a bottleneck for current proteomic studies using synaptoneurosomes. For this reason, we developed new steps for tissue homogenization and filtration that transform the preparation of synaptoneurosomes to a high-throughput, semi-automated process. We implemented a standardized protocol with easy to follow steps for homogenizing multiple samples simultaneously using a FastPrep tissue homogenizer (MP Biomedicals, LLC) and then filtering all of the samples in centrifugal filter units (EMD Millipore, Corp). The new steps dramatically reduce the time to prepare synaptoneurosomes from hours to minutes, increase sample recovery, and nearly double enrichment for synaptic proteins. These steps are also compatible with biosafety requirements for working with pathogen infected brain tissue. The new high-throughput semi-automated steps to prepare synaptoneurosomes are timely technical advances for studies of low abundance synaptic proteins in valuable tissue samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Fujii, Yuji; Henares, Terence G; Kawamura, Kunio; Endo, Tatsuro; Hisamoto, Hideaki
2012-04-21
To enhance sensitivity and facilitate easy sample introduction into a combinable poly(dimethylsiloxane) (PDMS) capillary (CPC) sensor array, PDMS was modified in bulk and on its surface to prepare "black" PDMS coated with a silver layer and self-assembled monolayer (SAM). India ink, a traditional Japanese black ink, was added to the PDMS pre-polymer for bulk modification. The surface was modified by a silver mirror reaction followed by SAM formation using cysteine. These modifications enhanced the fluorescence signals by reflecting them from the surface and reducing background interference. A decrease in the water contact angle led to enhanced sensitivity and easy sample introduction. Furthermore, a CPC sensor array for multiplex detection of serum sample components was prepared that could quantify the analytes glucose, potassium, and alkaline phosphatase (ALP). When serum samples were introduced by capillary action, the CPC sensor array showed fluorescence responses for each analyte and successfully identified the components with elevated concentrations in the serum samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hassan, Kazi; Siegal, Michael; Mowry, Curtis
This easy-to-operate, cost-effective, tabletop purge-and-trap gas chromatograph ensures safe drinking water and monitors disinfection by-product formation at water utilities in real-time without sample preparation or off-site analysis.
NASA Astrophysics Data System (ADS)
Sydoff, Marie; Stenström, Kristina
2010-04-01
The Department of Physics at Lund University is participating in a European Union project called EUMAPP (European Union Microdose AMS Partnership Programme), in which sample preparation and accelerator mass spectrometry (AMS) measurements of biological samples from microdosing studies have been made. This paper describes a simplified method of converting biological samples to solid graphite for 14C analysis with AMS. The method is based on online combustion of the samples, and reduction of CO 2 in septa-sealed vials. The septa-sealed vials and disposable materials are used to eliminate sample cross-contamination. Measurements of ANU and Ox I standards show deviations of 2% and 3%, respectively, relative to reference values. This level of accuracy is sufficient for biological samples from microdosing studies. Since the method has very few handling steps from sample to graphite, the risk of failure during the sample preparation process is minimized, making the method easy to use in routine preparation of samples.
Role of media in the preparation of Apamarga Ksharataila.
Gohil, Hitaba; Dhruve, Kinnari; Prajapati, P K
2010-07-01
Generally, Tailas and Ghritas have been prepared by using Kalka (paste) and Drava dravya (liquid media usually SwaRasa or Kwatha). However, Apamarga Kshara taila is prepared by using Apamarga Kshara drava (the alkali is obtained after dissolving it in water, after obtaining it by burning, dissolving, and filtration of the same plant). Therefore, to evaluate the role of the media during the preparation, the Taila was prepared in different samples by using the fresh and dry paste of Apamarga along with SwaRasa and Kwatha of Apamarga. All the samples were tested through various analytical parameters, that is, pH, acid value, iodine value, saponification value, and soon. Finally, it was found that Apamarga Kshara taila prepared by using fresh Kalka and Ksharajala was better and it was also an easy pharmaceutical procedure.
Single molecule targeted sequencing for cancer gene mutation detection.
Gao, Yan; Deng, Liwei; Yan, Qin; Gao, Yongqian; Wu, Zengding; Cai, Jinsen; Ji, Daorui; Li, Gailing; Wu, Ping; Jin, Huan; Zhao, Luyang; Liu, Song; Ge, Liangjin; Deem, Michael W; He, Jiankui
2016-05-19
With the rapid decline in cost of sequencing, it is now affordable to examine multiple genes in a single disease-targeted clinical test using next generation sequencing. Current targeted sequencing methods require a separate step of targeted capture enrichment during sample preparation before sequencing. Although there are fast sample preparation methods available in market, the library preparation process is still relatively complicated for physicians to use routinely. Here, we introduced an amplification-free Single Molecule Targeted Sequencing (SMTS) technology, which combined targeted capture and sequencing in one step. We demonstrated that this technology can detect low-frequency mutations using artificially synthesized DNA sample. SMTS has several potential advantages, including simple sample preparation thus no biases and errors are introduced by PCR reaction. SMTS has the potential to be an easy and quick sequencing technology for clinical diagnosis such as cancer gene mutation detection, infectious disease detection, inherited condition screening and noninvasive prenatal diagnosis.
Role of media in the preparation of Apamarga Ksharataila
Gohil, Hitaba; Dhruve, Kinnari; Prajapati, P. K.
2010-01-01
Generally, Tailas and Ghritas have been prepared by using Kalka (paste) and Drava dravya (liquid media usually SwaRasa or Kwatha). However, Apamarga Kshara taila is prepared by using Apamarga Kshara drava (the alkali is obtained after dissolving it in water, after obtaining it by burning, dissolving, and filtration of the same plant). Therefore, to evaluate the role of the media during the preparation, the Taila was prepared in different samples by using the fresh and dry paste of Apamarga along with SwaRasa and Kwatha of Apamarga. All the samples were tested through various analytical parameters, that is, pH, acid value, iodine value, saponification value, and soon. Finally, it was found that Apamarga Kshara taila prepared by using fresh Kalka and Ksharajala was better and it was also an easy pharmaceutical procedure. PMID:22131746
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wen, Haiming; Lin, Yaojun; Seidman, David N.
The preparation of transmission electron microcopy (TEM) samples from powders with particle sizes larger than ~100 nm poses a challenge. The existing methods are complicated and expensive, or have a low probability of success. Herein, we report a modified methodology for preparation of TEM samples from powders, which is efficient, cost-effective, and easy to perform. This method involves mixing powders with an epoxy on a piece of weighing paper, curing the powder–epoxy mixture to form a bulk material, grinding the bulk to obtain a thin foil, punching TEM discs from the foil, dimpling the discs, and ion milling the dimpledmore » discs to electron transparency. Compared with the well established and robust grinding–dimpling–ion-milling method for TEM sample preparation for bulk materials, our modified approach for preparing TEM samples from powders only requires two additional simple steps. In this article, step-by-step procedures for our methodology are described in detail, and important strategies to ensure success are elucidated. Furthermore, our methodology has been applied successfully for preparing TEM samples with large thin areas and high quality for many different mechanically milled metallic powders.« less
Wen, Haiming; Lin, Yaojun; Seidman, David N.; ...
2015-09-09
The preparation of transmission electron microcopy (TEM) samples from powders with particle sizes larger than ~100 nm poses a challenge. The existing methods are complicated and expensive, or have a low probability of success. Herein, we report a modified methodology for preparation of TEM samples from powders, which is efficient, cost-effective, and easy to perform. This method involves mixing powders with an epoxy on a piece of weighing paper, curing the powder–epoxy mixture to form a bulk material, grinding the bulk to obtain a thin foil, punching TEM discs from the foil, dimpling the discs, and ion milling the dimpledmore » discs to electron transparency. Compared with the well established and robust grinding–dimpling–ion-milling method for TEM sample preparation for bulk materials, our modified approach for preparing TEM samples from powders only requires two additional simple steps. In this article, step-by-step procedures for our methodology are described in detail, and important strategies to ensure success are elucidated. Furthermore, our methodology has been applied successfully for preparing TEM samples with large thin areas and high quality for many different mechanically milled metallic powders.« less
Abe, Shigeaki; Hyono, Atsushi; Kawai, Koji; Yonezawa, Tetsu
2014-03-01
In this study, we investigated conductivity preparation for scanning electron microscope (SEM) observation that used novel asymmetrical choline-type room temperature ionic liquids (RTIL). By immersion in only an RTIL solution, clear SEM images of several types of biological samples were successfully observed. In addition, we could visualize protozoans using RTILs without any dilution. These results suggested that the asymmetrical choline-type RTILs used in this study are suitable for visualizing of biological samples by SEM. Treatment without the need for dilution can obviate the need for adjusting the RTIL concentration and provide for a rapid and easy conductivity treatment for insulating samples.
Jeong, In-Seek; Kwak, Byung-Man; Ahn, Jang-Hyuk; Leem, Donggil; Yoon, Taehyung; Yoon, Changyong; Jeong, Jayoung; Park, Jung-Min; Kim, Jin-Man
2012-10-01
In this study, nonheated saponification was employed as a novel, rapid, and easy sample preparation method for the determination of cholesterol in emulsified foods. Cholesterol content was analyzed using gas chromatography with a flame ionization detector (GC-FID). The cholesterol extraction method was optimized for maximum recovery from baby food and infant formula. Under these conditions, the optimum extraction solvent was 10 mL ethyl ether per 1 to 2 g sample, and the saponification solution was 0.2 mL KOH in methanol. The cholesterol content in the products was determined to be within the certified range of certified reference materials (CRMs), NIST SRM 1544 and SRM 1849. The results of the recovery test performed using spiked materials were in the range of 98.24% to 99.45% with an relative standard devitation (RSD) between 0.83% and 1.61%. This method could be used to reduce sample pretreatment time and is expected to provide an accurate determination of cholesterol in emulsified food matrices such as infant formula and baby food. A novel, rapid, and easy sample preparation method using nonheated saponification was developed for cholesterol detection in emulsified foods. Recovery tests of CRMs were satisfactory, and the recoveries of spiked materials were accurate and precise. This method was effective and decreased the time required for analysis by 5-fold compared to the official method. © 2012 Institute of Food Technologists®
Spötl, Christoph
2005-09-01
The stable carbon isotopic composition of dissolved inorganic carbon (delta13C(DIC)) is traditionally determined using either direct precipitation or gas evolution methods in conjunction with offline gas preparation and measurement in a dual-inlet isotope ratio mass spectrometer. A gas evolution method based on continuous-flow technology is described here, which is easy to use and robust. Water samples (100-1500 microl depending on the carbonate alkalinity) are injected into He-filled autosampler vials in the field and analysed on an automated continuous-flow gas preparation system interfaced to an isotope ratio mass spectrometer. Sample analysis time including online preparation is 10 min and overall precision is 0.1 per thousand. This method is thus fast and can easily be automated for handling large sample batches.
Schmidt, Eduardo Morgado; Franco, Marcos Fernando; Cuelbas, Claudio José; Zacca, Jorge Jardim; de Carvalho Rocha, Werickson Fortunato; Borges, Rodrigo; de Souza, Wanderley; Sawaya, Alexandra Christine Helena Frankland; Eberlin, Marcos Nogueira; Correa, Deleon Nascimento
2015-09-01
Using Brazilian banknotes as a test case, forensic examination and identification of Rhodamine B dye anti-theft device (ATD) staining on banknotes were performed. Easy ambient sonic spray ionization mass spectrometry (EASI-MS) was used since it allows fast and simple analysis with no sample preparation providing molecular screening of the surface with direct desorption and ionization of the security dye. For a more accurate molecular characterization of the ATD dye, Q Exactive Orbitrap™ Fourier transform (tandem) mass spectrometry using eletrospray ionization (ESI-HRMS/MS) was also applied. Copyright © 2015 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.
Superconductivity in sputtered CuMO6S8
NASA Technical Reports Server (NTRS)
Alterovitz, S.; Woollam, J. A.; Kammerdiner, L.; Luo, H. L.; Martin, C.
1977-01-01
Samples were prepared by melting the metals, followed by annealing to various temperatures. The result was a structurally weak material. Sputtered films on sapphire substrates were prepared and studied. The substrates give the films mechanical strength and permit easy attachment of electrical leads. Materials were characterized by X-ray diffraction, electron microscopy, electrical resistance vs. temperature, and critical current measurements. Some of the results on CuMo6S8 are presented.
Rapid Determination of Mercury in Seafood in an Introductory Environmental Science Class
ERIC Educational Resources Information Center
Rice, Jeanette K.; Jenkins, J. David; Manley, A. Citabria; Sorel, Eric; Smith, C. Jimmy
2005-01-01
An experiment is described which allows easy, rapid determination of mercury levels in commercially seafood samples from a contaminated area. Students gain experience in the preparation of a calibration curve, the determination of unknown concentrations, and risk assessment based on experimentally determined data.
USDA-ARS?s Scientific Manuscript database
A new method of sample preparation was developed and is reported for the first time. The approach combines in-vial filtration with dispersive solid-phase extraction (d-SPE) in a fast and convenient cleanup of QuEChERS (quick, easy, cheap, effective, rugged, and safe) extracts. The method was appli...
USDA-ARS?s Scientific Manuscript database
The QuEChERS (quick, easy, cheap, effective, rugged, and safe) sample preparation method was modified to accommodate various cereal grain matrices (corn, oat, rice and wheat) and provide good analytical results (recoveries in the range of 70-120% and RSDs <20%) for the majority of the target pestici...
Multiplex screening of persistent organic pollutants in fish using spectrally encoded microspheres
USDA-ARS?s Scientific Manuscript database
Persistent organic pollutants (POPs) are food contaminants of global public health concern and known to be carcinogenic and endocrine disruptors. Their monitoring is essential and an easy-to-use, rapid and affordable multi-analyte screening method with simplified sample preparation can be a valuable...
USDA-ARS?s Scientific Manuscript database
A multiresidue analytical method using a modification of the “quick, easy, cheap, effective, rugged, and safe” (QuEChERS) sample preparation approach combined with liquid chromatography–tandem mass spectrometry (LC-MS/MS) analysis was established and validated for the rapid determination of 69 pesti...
EASI-IMS an expedite and secure technique to screen for 25I-NBOH in blotter papers.
de Morais, Damila Rodrigues; Barbosa, Ingrid Lopes; Cunha, Kelly Francisco; Tripodi, Guilherme Lucas; Angolini, Célio Fernando Figueiredo; Franco, Marcos Fernando; de Aquino, Elvis Medeiros; Eberlin, Marcos Nogueira; Costa, Jose Luiz
2017-10-01
The increasing number of new psychoactive substances (NPS) and their quick worldwide spreading, often only slightly modified in the form of new derivatives and analogues, have brought the need for fast, wide-ranging, and unequivocal identification methods in clinical and forensic investigations. Because it usually provides secure results, gas chromatography coupled to mass spectrometry (GC-MS) has been routinely employed as the standard technique for the detection of NPS in blotter papers. For 25I-NBOH (N-(2-hydroxybenzyl)-2-(4-iodo-2,5-dimethoxyphenyl)ethan-1-aminium), however, GC-MS analysis of an blotter paper extract leads to incorrect results. In this work, we investigated whether easy ambient sonic-spray mass spectrometry imaging (EASI-IMS), and ambient ionization MS method can be applied directly to the surface of the sample requiring therefore no extraction or sample preparations, would serve as an efficient, sensitive, and secure alternative for 25I-NBOH screening. Copyright © 2017 John Wiley & Sons, Ltd.
AAO-based nanoreservoir arrays: A quick and easy support for TEM characterization
NASA Astrophysics Data System (ADS)
Mace, M.; Sahaf, H.; Moyen, E.; Bedu, F.; Masson, L.; Hanbücken, M.
2010-12-01
Large-scale arrays of calibrated, nanometer sized reservoirs are prepared by adapting the well-established electrochemical method used so far for the preparation of anodic aluminium oxide (AAO) membranes. The bottom plane of the assembly is prepared to be transparent for high-energy electrons, enabling their use as a universal sample support for transmission electron microscopy studies of nanoparticles. The nanoreservoir substrates can be cleaned under ultra-high-vacuum conditions and filled, by evaporating different materials. Filled nanoreservoirs can locally be sealed with a thin carbon layer using focused-ion-beam-induced deposition (FIBID). Nanoparticles, grow at various adsorption places on the walls and bottom planes inside the nanoreservoirs. They can be characterized by transmission electron microscopy (TEM) without further sample preparation in different crystallographic directions. Due to the dense array-arrangement of the reservoirs, very good statistics can already be obtained on one single sample. The controlled fabrication of the nanoreservoir array and first TEM results obtained on Au nanoparticles before and after sealing of the reservoirs, are presented.
USDA-ARS?s Scientific Manuscript database
Despite its many documented advantages, the QuEChERS (quick, easy, cheap, effective, rugged and safe) sample preparation approach has problems with a few unstable pesticides, partly due to the exothermic reaction generated by the use of anhydrous magnesium sulfate during extraction. These pesticide...
Colorimetric assay for urinary track infection disease diagnostic on flexible substrate
NASA Astrophysics Data System (ADS)
Safavieh, Mohammadali; Ahmed, Minhaz Uddin; Zourob, Mohammed
2012-10-01
We are presenting cassette as a novel point of care diagnostic device. This device is easy to use, low cost to prepare, high throughput and can analyze several samples at the same time. We first, demonstrate the preparation method of the device. Then, fabrication of the flexible substrate has been presented. The device has been used for detection of the real sample of E.coli bacteria following by colorimetric detection. We have shown that we could detect 30 cfu/ml bacteria and 100 fg/μl of Staphylococous aureus DNA in 1 hr using LAMP amplification technique. This device will be helpful in hospitals and doctor's office for analysis of several patients' samples at the same time.
Matrix effects in pesticide multi-residue analysis by liquid chromatography-mass spectrometry.
Kruve, Anneli; Künnapas, Allan; Herodes, Koit; Leito, Ivo
2008-04-11
Three sample preparation methods: Luke method (AOAC 985.22), QuEChERS (quick, easy, cheap, effective, rugged and safe) and matrix solid-phase dispersion (MSPD) were applied to different fruits and vegetables for analysis of 14 pesticide residues by high-performance liquid chromatography with electrospray ionization-mass spectrometry (HPLC/ESI/MS). Matrix effect, recovery and process efficiency of the sample preparation methods applied to different fruits and vegetables were compared. The Luke method was found to produce least matrix effect. On an average the best recoveries were obtained with the QuEChERS method. MSPD gave unsatisfactory recoveries for some basic pesticide residues. Comparison of matrix effects for different apple varieties showed high variability for some residues. It was demonstrated that the amount of co-extracting compounds that cause ionization suppression of aldicarb depends on the apple variety as well as on the sample preparation method employed.
Comolli, Luis R; Duarte, Robert; Baum, Dennis; Luef, Birgit; Downing, Kenneth H; Larson, David M; Csencsits, Roseann; Banfield, Jillian F
2012-06-01
We present a modern, light portable device specifically designed for environmental samples for cryogenic transmission-electron microscopy (cryo-TEM) by on-site cryo-plunging. The power of cryo-TEM comes from preparation of artifact-free samples. However, in many studies, the samples must be collected at remote field locations, and the time involved in transporting samples back to the laboratory for cryogenic preservation can lead to severe degradation artifacts. Thus, going back to the basics, we developed a simple mechanical device that is light and easy to transport on foot yet effective. With the system design presented here we are able to obtain cryo-samples of microbes and microbial communities not possible to culture, in their near-intact environmental conditions as well as in routine laboratory work, and in real time. This methodology thus enables us to bring the power of cryo-TEM to microbial ecology. Copyright © 2011 Wiley Periodicals, Inc.
Ugalde, Maciel; Brand, Leah; Beltran, Alicia; Dadabhoy, Hafza; Chen, Tzu-An; O'Connor, Teresia M; Hughes, Sheryl O; Buday, Richard; Nicklas, Theresa A; Baranowski, Janice
2017-01-01
Background Vegetables are an important part of a healthy diet because they help prevent several chronic diseases. Mothers of preschoolers reported difficulty getting their young children to eat vegetables, and many did not know how to cook child-pleasing recipes. Objective The cooking habits of mothers of preschoolers, their perceptions of recipes designed for their children, and the involvement of their children in food preparation were assessed to inform a food parenting video game called Mommio. Methods A cross-sectional survey design was used. Eligibility criteria included mothers of 3- to 5-year-old children who reported difficulty getting their children to eat vegetables. Participants completed a demographic questionnaire with questions about their food preparation practices. They were asked to select up to 4 of the 10 provided recipes they wanted to try and to prepare and report back on their experiences. Results Most (46) of the 50 recipes included in Mommio’s in-game recipe box were evaluated at least once and some up to 5 times with a total of 85 evaluations. This well-educated, mostly employed, sample of 27 mothers of preschoolers preferred simple, quick recipes. They ate primarily at home, made dinners from scratch, and indicated that the 46 recipes were generally simple, quick, and easy to prepare. Involvement in preparation enhanced their child’s acceptance of the food. Prior food and preparation preferences influenced the children’s acceptance of the dish at the ensuing meal. Conclusions The high rate of home recipe preparation indicated that including a recipe selection and preparation component in a food parenting video game could be attractive and may enhance effectiveness. Mothers reported that the recipes provided were generally easy to prepare, tasted good, and the instructions were easy to understand, suggesting they could be helpful to the mothers when playing a vegetable parenting game. Some mothers reported that involving their children in recipe preparation influenced their children’s willingness to eat the vegetables. The highest rated recipes are being included in the game, and mothers will be encouraged to involve their children in recipe preparation. PMID:29042344
USDA-ARS?s Scientific Manuscript database
The technique of QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) is only 7 years old, yet it is revolutionizing the manner in which multiresidue, multiclass pesticide analysis (and perhaps beyond) is performed. Columnist Ron Majors sits down with inventors Steve Lehotay and Michelangelo An...
Clinical utility of an automated instrument for gram staining single slides.
Baron, Ellen Jo; Mix, Samantha; Moradi, Wais
2010-06-01
Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis.
Receptor-based screening assays for the detection of antibiotics residues - A review.
Ahmed, Saeed; Ning, Jianan; Cheng, Guyue; Ahmad, Ijaz; Li, Jun; Mingyue, Liu; Qu, Wei; Iqbal, Mujahid; Shabbir, M A B; Yuan, Zonghui
2017-05-01
Consumer and regulatory agencies have a high concern to antibiotic residues in food producing animals, so appropriate screening assays of fast, sensitive, low cost, and easy sample preparation for the identification of these residues are essential for the food-safety insurance. Great efforts in the development of a high-throughput antibiotic screening assay have been made in recent years. Concerning the screening of antibiotic residue, this review elaborate an overview on the availability, advancement and applicability of antibiotic receptor based screening assays for the safety assessment of antibiotics usage (i.e. radio receptor assay, enzyme labeling assays, colloidal gold receptor assay, enzyme colorimetry assay and biosensor assay). This manuscript also tries to shed a light on the selection, preparation and future perspective of receptor protein for antibiotic residue detection. These assays have been introduced for the screening of numerous food samples. Receptor based screening technology for antibiotic detection has high accuracy. It has been concluded that at the same time, it can detect a class of drugs for certain receptor, and realize the multi-residue detection. These assays offer fast, easy and precise detection of antibiotics. Copyright © 2017 Elsevier B.V. All rights reserved.
Peng, Sean X; Cousineau, Martin; Juzwin, Stephen J; Ritchie, David M
2006-01-01
A novel 96-well screen filter plate (patent pending) has been invented to eliminate a time-consuming and labor-intensive step in preparation of in vivo study samples--to remove blood or plasma clots. These clots plug the pipet tips during a manual or automated sample-transfer step causing inaccurate pipetting or total pipetting failure. Traditionally, these blood and plasma clots are removed by picking them out manually one by one from each sample tube before any sample transfer can be made. This has significantly slowed the sample preparation process and has become a bottleneck for automated high-throughput sample preparation using robotic liquid handlers. Our novel screen filter plate was developed to solve this problem. The 96-well screen filter plate consists of 96 stainless steel wire-mesh screen tubes connected to the 96 openings of a top plate so that the screen filter plate can be readily inserted into a 96-well sample storage plate. Upon insertion, the blood and plasma clots are excluded from entering the screen tube while clear sample solutions flow freely into it. In this way, sample transfer can be easily completed by either manual or automated pipetting methods. In this report, three structurally diverse compounds were selected to evaluate and validate the use of the screen filter plate. The plasma samples of these compounds were transferred and processed in the presence and absence of the screen filter plate and then analyzed by LC-MS/MS methods. Our results showed a good agreement between the samples prepared with and without the screen filter plate, demonstrating the utility and efficiency of this novel device for preparation of blood and plasma samples. The device is simple, easy to use, and reusable. It can be employed for sample preparation of other biological fluids that contain floating particulates or aggregates.
Zhang, Yaohai; Zhang, Xuelian; Jiao, Bining
2014-09-15
Dispersive liquid-liquid microextraction (DLLME) sample preparation and the quick, easy, cheap, effective, rugged and safe (QuEChERS) method combined with DLLME were developed and compared for the analysis of ten pyrethroids in various fruit juices using gas chromatography-electron capture detection (GC-ECD). QuEChERS-DLLME method has found its widespread applications to all the fruit juices including those samples with more complex matrices (orange, lemon, kiwi and mango) while DLLME was confined to the fruit juices with simpler matrices (apple, pear, grape and peach). The two methods provided acceptable recoveries and repeatability. In addition, the applicabilities of two methods were demonstrated with the real samples and further confirmed by gas chromatography-mass spectrometry (GC-MS). Copyright © 2014. Published by Elsevier Ltd.
Juliano, Claudia; Manconi, Paola; Cossu, Massimo
2016-09-01
Perna canaliculus is a nutritional supplement recently studied and highly recommended for its anti-inflammatory effects in both animals and humans. In this study, the physicochemical properties, the microbiological quality, the total lipid content and fatty acids composition of three commercial samples of Perna powder were determined. Subsequently, three simple formulations of extemporaneous oral pastes containing Perna were prepared and designed for veterinary use. Their microbiological stability was assessed after 1-month storage at either room temperature or 35 °C. The results demonstrated that commercial Perna samples lack homogeneity, in regard to some technological properties and fatty acid composition; therefore, a preliminary characterisation of commercial Perna samples is recommended to assure the quality of formulations containing this nutritional supplement. Oral paste formulations are easy and simple to prepare and show good physical and microbiological stability, suggesting their large-scale production.
A Combined Fabrication and Instrumentation Platform for Sample Preparation.
Guckenberger, David J; Thomas, Peter C; Rothbauer, Jacob; LaVanway, Alex J; Anderson, Meghan; Gilson, Dan; Fawcett, Kevin; Berto, Tristan; Barrett, Kevin; Beebe, David J; Berry, Scott M
2014-06-01
While potentially powerful, access to molecular diagnostics is substantially limited in the developing world. Here we present an approach to reduced cost molecular diagnostic instrumentation that has the potential to empower developing world communities by reducing costs through streamlining the sample preparation process. In addition, this instrument is capable of producing its own consumable devices on demand, reducing reliance on assay suppliers. Furthermore, this instrument is designed with an "open" architecture, allowing users to visually observe the assay process and make modifications as necessary (as opposed to traditional "black box" systems). This open environment enables integration of microfluidic fabrication and viral RNA purification onto an easy-to-use modular system via the use of interchangeable trays. Here we employ this system to develop a protocol to fabricate microfluidic devices and then use these devices to isolate viral RNA from serum for the measurement of human immunodeficiency virus (HIV) viral load. Results obtained from this method show significantly reduced error compared with similar nonautomated sample preparation processes. © 2014 Society for Laboratory Automation and Screening.
An apparatus for preparing benthic samples aboard ship
Pepper, Phillip N.; Girard, Thomas L.; Stapanian, Martin A.
2001-01-01
We describe a safe and effective apparatus for washing and reducing the volume of benthic samples collected by grab samplers aboard ship. The sample is transferred directly from the dredge to the apparatus and then washed with water pumped through pipes in the apparatus and from onboard hoses. Wastewater and materials smaller than 0.541 mm in diameter are washed overboard. Larger materials, including benthic organisms, collect on an upper 0.64-cm screen and on a lower 30-mm-mesh stainless steel bolt cloth. A collection jar is screwed into the bottom of the apparatus. Therefore, transfer of sample material from the apparatus to the jar is quick and easy. This apparatus has several advantages for use aboard ship over others described in the literature, especially in rough seas, in cold weather, and at night. The apparatus provides a safe and convenient platform for washing and reducing samples, and samples can be prepared while the vessel is traveling at full speed.
Sapozhnikova, Yelena; Simons, Tawana; Lehotay, Steven J
2015-05-13
A simple, fast, and cost-effective sample preparation method, previously developed and validated for the analysis of organic contaminants in fish using low-pressure gas chromatography-tandem mass spectrometry (LPGC-MS/MS), was evaluated for the analysis of polybrominated diphenyl ethers (PBDEs) and dichlorodiphenyltrichloroethane (DDT) pesticides using enzyme-linked immunosorbent assay (ELISA). The sample preparation technique was based on the quick, easy, cheap, rugged, effective, and safe (QuEChERS) approach with filter-vial dispersive solid phase extraction (d-SPE). Incurred PBDEs and DDTs were analyzed in three types of fish with 3-10% lipid content: Pacific croaker, salmon, and National Institute of Standards and Technology (NIST) Standard Reference Material 1947 (Lake Michigan fish tissue). LPGC-MS/MS and ELISA results were in agreement: 108-111 and 65-82% accuracy ELISA versus LPGC-MS/MS results for PBDEs and DDTs, respectively. Similar detection limits were achieved for ELISA and LPGC-MS/MS. Matrix effects (MEs) were significant (e.g., -60%) for PBDE measurement in ELISA, but not a factor in the case of DDT pesticides. This study demonstrated that the sample preparation method can be adopted for semiquantitative screening analysis of fish samples by commercial kits for PBDEs and DDTs.
Jin, Huang; Chun-Lian, Tang; Zu-Wu, Tu; Li, Tang; Ke-Hui, Zhang; Qian, Li; Jun, Ye
2018-04-18
To prepare freeze-drying control materials of IgG antibody against Schistosoma japonicum for detection kits. The serum samples of schistosomiasis patients from endemic areas and normal people without history of schistosome infection or contact with infested water in Hubei Province were collected. All the sera were detected by the method approved by China Food and Drug Administration and selected for preparation of quality control samples. Totally twelve positive quality control materials, ten negative quality control materials, and one sensitive and one precision quality control materials were screened. According to the positive serum level, the positive degrees of quality control materials were divided into strong, medium and weak levels. The stability could be valid for one year. The freeze-drying quality control materials of IgG antibody against S. japonicum for detection kits are prepared. They are easy to use and have good stability, and therefore, they may meet the requirement of quality control for the detection of schistosomiasis diagnostics kits.
Ugalde, Maciel; Brand, Leah; Beltran, Alicia; Dadabhoy, Hafza; Chen, Tzu-An; O'Connor, Teresia M; Hughes, Sheryl O; Baranowski, Tom; Buday, Richard; Nicklas, Theresa A; Baranowski, Janice
2017-10-17
Vegetables are an important part of a healthy diet because they help prevent several chronic diseases. Mothers of preschoolers reported difficulty getting their young children to eat vegetables, and many did not know how to cook child-pleasing recipes. The cooking habits of mothers of preschoolers, their perceptions of recipes designed for their children, and the involvement of their children in food preparation were assessed to inform a food parenting video game called Mommio. A cross-sectional survey design was used. Eligibility criteria included mothers of 3- to 5-year-old children who reported difficulty getting their children to eat vegetables. Participants completed a demographic questionnaire with questions about their food preparation practices. They were asked to select up to 4 of the 10 provided recipes they wanted to try and to prepare and report back on their experiences. Most (46) of the 50 recipes included in Mommio's in-game recipe box were evaluated at least once and some up to 5 times with a total of 85 evaluations. This well-educated, mostly employed, sample of 27 mothers of preschoolers preferred simple, quick recipes. They ate primarily at home, made dinners from scratch, and indicated that the 46 recipes were generally simple, quick, and easy to prepare. Involvement in preparation enhanced their child's acceptance of the food. Prior food and preparation preferences influenced the children's acceptance of the dish at the ensuing meal. The high rate of home recipe preparation indicated that including a recipe selection and preparation component in a food parenting video game could be attractive and may enhance effectiveness. Mothers reported that the recipes provided were generally easy to prepare, tasted good, and the instructions were easy to understand, suggesting they could be helpful to the mothers when playing a vegetable parenting game. Some mothers reported that involving their children in recipe preparation influenced their children's willingness to eat the vegetables. The highest rated recipes are being included in the game, and mothers will be encouraged to involve their children in recipe preparation. ©Maciel Ugalde, Leah Brand, Alicia Beltran, Hafza Dadabhoy, Tzu-An Chen, Teresia M O'Connor, Sheryl O Hughes, Tom Baranowski, Richard Buday, Theresa A Nicklas, Janice Baranowski. Originally published in JMIR Serious Games (http://games.jmir.org), 17.10.2017.
USDA-ARS?s Scientific Manuscript database
An easy and reliable high-throughput analysis method was developed and validated for 192 diverse pesticides and 51 environmental contaminants (13 PCB congeners, 14 PAHs, 7 PBDE congeners, and 17 novel flame retardants) in cattle, swine, and poultry muscle. Sample preparation was based on the “quick,...
Clinical Utility of an Automated Instrument for Gram Staining Single Slides ▿
Baron, Ellen Jo; Mix, Samantha; Moradi, Wais
2010-01-01
Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis. PMID:20410348
Rahman, Md Musfiqur; Abd El-Aty, A M; Kim, Sung-Woo; Shin, Sung Chul; Shin, Ho-Chul; Shim, Jae-Han
2017-01-01
In pesticide residue analysis, relatively low-sensitivity traditional detectors, such as UV, diode array, electron-capture, flame photometric, and nitrogen-phosphorus detectors, have been used following classical sample preparation (liquid-liquid extraction and open glass column cleanup); however, the extraction method is laborious, time-consuming, and requires large volumes of toxic organic solvents. A quick, easy, cheap, effective, rugged, and safe method was introduced in 2003 and coupled with selective and sensitive mass detectors to overcome the aforementioned drawbacks. Compared to traditional detectors, mass spectrometers are still far more expensive and not available in most modestly equipped laboratories, owing to maintenance and cost-related issues. Even available, traditional detectors are still being used for analysis of residues in agricultural commodities. It is widely known that the quick, easy, cheap, effective, rugged, and safe method is incompatible with conventional detectors owing to matrix complexity and low sensitivity. Therefore, modifications using column/cartridge-based solid-phase extraction instead of dispersive solid-phase extraction for cleanup have been applied in most cases to compensate and enable the adaptation of the extraction method to conventional detectors. In gas chromatography, the matrix enhancement effect of some analytes has been observed, which lowers the limit of detection and, therefore, enables gas chromatography to be compatible with the quick, easy, cheap, effective, rugged, and safe extraction method. For liquid chromatography with a UV detector, a combination of column/cartridge-based solid-phase extraction and dispersive solid-phase extraction was found to reduce the matrix interference and increase the sensitivity. A suitable double-layer column/cartridge-based solid-phase extraction might be the perfect solution, instead of a time-consuming combination of column/cartridge-based solid-phase extraction and dispersive solid-phase extraction. Therefore, replacing dispersive solid-phase extraction with column/cartridge-based solid-phase extraction in the cleanup step can make the quick, easy, cheap, effective, rugged, and safe extraction method compatible with traditional detectors for more sensitive, effective, and green analysis. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Magic Angle Spinning NMR Metabolomics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhi Hu, Jian
Nuclear Magnetic Resonance (NMR) spectroscopy is a non-destructive, quantitative, reproducible, untargeted and unbiased method that requires no or minimal sample preparation, and is one of the leading analytical tools for metabonomics research [1-3]. The easy quantification and the no need of prior knowledge about compounds present in a sample associated with NMR are advantageous over other techniques [1,4]. 1H NMR is especially attractive because protons are present in virtually all metabolites and its NMR sensitivity is high, enabling the simultaneous identification and monitoring of a wide range of low molecular weight metabolites.
USDA-ARS?s Scientific Manuscript database
The “quick, easy, cheap, effective, rugged, and safe” (QuEChERS) approach to sample preparation is widely applied in pesticide residue analysis, but the use of magnesium sulfate for salting out in the method is not ideal for mass spectrometry. In this study we developed and evaluated three new diffe...
Klimek-Turek, A; Sikora, M; Rybicki, M; Dzido, T H
2016-03-04
A new concept of using thin-layer chromatography to sample preparation for the quantitative determination of solute/s followed by instrumental techniques is presented Thin-layer chromatography (TLC) is used to completely separate acetaminophen and its internal standard from other components (matrix) and to form a single spot/zone containing them at the solvent front position (after the final stage of the thin-layer chromatogram development). The location of the analytes and internal standard in the solvent front zone allows their easy extraction followed by quantitation by HPLC. The exctraction procedure of the solute/s and internal standard can proceed from whole solute frontal zone or its part without lowering in accuracy of quantitative analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Spacer layer thickness dependent structural and magnetic properties of Co/Si multilayers
NASA Astrophysics Data System (ADS)
Roy, Ranjan; Singh, Dushyant; Kumar, M. Senthil
2018-05-01
In this article, the study of high resolution x-ray diffraction and magnetization of sputter deposited Co/Si multilayer is reported. Multilayers are prepared at ambient temperature by dc magnetron sputtering. Structural properties are studied by high resolution x-ray diffraction. Magnetic properties are studied at room temperature by vibrating sample magnetometer. Structural properties show that the Co layer is polycrystalline and the Si layer is amorphous. The magnetization study indicates that the samples are soft ferromagnetic in nature. The study of magnetization also shows that the easy axis of magnetization lies in the plane of the film.
Liu, Ruimei; Feng, Feng; Chen, Guolin; Liu, Zhimin; Xu, Zhigang
2016-07-01
This study reports the development of a novel dummy template molecularly imprinted polymer (MIP)-coated barbell-shaped stir bar. The MIP stir bar coatings were prepared by using 2,2-bis(4-hydroxyphenyl)butane (BPB), 4,4'-dihydroxydiphenylmethane (BPF), 4-tert-butylphenol (PTBP), and tetrabromobisphenol A (TBBA) as dummy templates using a capillary in situ polymerization method. Uniform coatings can be prepared controllably. The method is simple, easy, and reproducible. The barbell-shaped stir bar was developed by using medical silicone tubes as wheels. The wheels could be removed and reinstalled when necessary; therefore, the barbell-shaped stir bar was easy to disassemble and reassemble. The novel MIP-coated stir bar showed good selectivity for the target analyte, bisphenol A (BPA). The established method is selective and sensitive with a lower detection limit for BPA of 0.003 μg/L. The dummy template MIP-coated stir bar is suitable for trace BPA analysis in real environmental water samples without template leakage. The novel stir bar can be used at least 100 times.
One-pot preparation of mRNA/cDNA display by a novel and versatile puromycin-linker DNA.
Mochizuki, Yuki; Biyani, Manish; Tsuji-Ueno, Sachika; Suzuki, Miho; Nishigaki, Koichi; Husimi, Yuzuru; Nemoto, Naoto
2011-09-12
A rapid, easy, and robust preparation method for mRNA/cDNA display using a newly designed puromycin-linker DNA is presented. The new linker is structurally simple, easy to synthesize, and cost-effective for use in "in vitro peptide and protein selection". An introduction of RNase T1 nuclease site to the new linker facilitates the easy recovery of mRNA/cDNA displayed protein by an improvement of the efficiency of ligating the linker to mRNAs and efficient release of mRNA/cDNA displayed protein from the solid-phase (magnetic bead). For application demonstration, affinity selections were successfully performed. Furthermore, we introduced a "one-pot" preparation protocol to perform mRNA display easy. Unlike conventional approaches that require tedious and downstream multistep process including purification, this protocol will make the mRNA/cDNA display methods more practical and convenient and also facilitate the development of next-generation, high-throughput mRNA/cDNA display systems amenable to automation.
Sudhakaran, R; Mekata, T; Kono, T; Supamattaya, K; Linh, N T H; Suzuki, Y; Sakai, M; Itami, T
2009-07-01
White spot syndrome virus (WSSV) is an important shrimp pathogen responsible for large economic losses for the shrimp culture industry worldwide. The nucleic acids of the virus must be adequately preserved and transported from the field to the laboratory before molecular diagnostic analysis is performed. Here, we developed a new method to isolate WSSV-DNA using Flinders Technology Associates filter paper (FTA matrix card; Whatman) without centrifugation or hazardous steps involved. FTA technology is a new method allowing the simple collection, shipment and archiving of nucleic acids from haemolymph samples providing DNA protection against nucleases, oxidation, UV damage, microbial and fungal attack. DNA samples prepared from 10-fold dilutions of moribund shrimp haemolymph using FTA matrix cards were analysed using semi-quantitative and quantitative polymerase chain reaction (PCR) and were compared with two commercially available DNA isolation methods, the blood GenomicPrep Mini Spin Kit (GE Healthcare) and the DNAzol (Invitrogen). Sequence analysis was performed for the DNA samples prepared using the various isolation procedures and no differences in the sequence among these methods were identified. Results based on the initial copy number of DNA prepared from the GenomicPrep Mini Spin Kit are a little more sensitive than the DNA prepared from FTA matrix cards, whereas the DNAzol method is not suitable for blood samples. Our data shows the efficiency of retention capacity of WSSV-DNA samples from impregnated FTA matrix cards. Matrix cards were easy to store and ship for long periods of time. They provide ease of handling and are a reliable alternative for sample collection and for molecular detection and characterization of WSSV isolates.
Automatic recognition and analysis of synapses. [in brain tissue
NASA Technical Reports Server (NTRS)
Ungerleider, J. A.; Ledley, R. S.; Bloom, F. E.
1976-01-01
An automatic system for recognizing synaptic junctions would allow analysis of large samples of tissue for the possible classification of specific well-defined sets of synapses based upon structural morphometric indices. In this paper the three steps of our system are described: (1) cytochemical tissue preparation to allow easy recognition of the synaptic junctions; (2) transmitting the tissue information to a computer; and (3) analyzing each field to recognize the synapses and make measurements on them.
Jin, Yue; Zhang, Jinzhen; Zhao, Wen; Zhang, Wenwen; Wang, Lin; Zhou, Jinhui; Li, Yi
2017-04-15
The aim of this study was to develop an analytical method for the analysis of a wide range of veterinary drugs in honey and royal jelly. A modified sample preparation procedure based on the quick, easy, cheap, effective, rugged and safe (QuEChERS) method was developed, followed by liquid chromatography tandem mass spectrometry determination. Use of the single sample preparation method for analysis of 42 veterinary drugs becomes more valuable because honey and royal jelly belong to completely different complex matrices. Another main advantage of the proposed method is its ability to identify and quantify 42 veterinary drugs with higher sensitivity than reference methods of China. This work has shown that the reported method was demonstrated to be convenient and reliable for the quick monitoring of veterinary drugs in honey and royal jelly samples. Copyright © 2016 Elsevier Ltd. All rights reserved.
Radio- and photoluminescence properties of Ce/Tb co-doped glasses with huntite-like composition
NASA Astrophysics Data System (ADS)
Lorenzi, Roberto; Golubev, Nikita V.; Ziaytdinova, Mariyam Z.; Jarý, Vítězslav; Babin, Vladimir; Malashkevich, Georgii E.; Paleari, Alberto; Sigaev, Vladimir N.; Fasoli, Mauro; Nikl, Martin
2018-04-01
Optical properties of yttria-aluminoborate (YAB) glasses with general composition 10(CexTbyY(1-x-y))-30Al2O3-60B2O3 are investigated and compared with data available on YAB crystals with huntite-like structure. Ce doped samples show optical features ascribable to preferential location of rare earth ions in sites with specific geometry similar to that observed in crystalline structures. Samples prepared with Tb ions as emission activator and Ce ions as sensitizer have been studied within the framework of non-radiative energy transfer. The resulting Förster radius is of 4.6 ± 0.5 Å comparable with that observed in Ce/Tb co-doped YAl3(BO3)4 crystals. The investigated materials possess radio- and photoluminescence emission efficiencies and performances comparable to that of crystalline counterparts with the advantage of having easiness of preparation and workability typical of glassy systems.
Optimization of protein buffer cocktails using Thermofluor.
Reinhard, Linda; Mayerhofer, Hubert; Geerlof, Arie; Mueller-Dieckmann, Jochen; Weiss, Manfred S
2013-02-01
The stability and homogeneity of a protein sample is strongly influenced by the composition of the buffer that the protein is in. A quick and easy approach to identify a buffer composition which increases the stability and possibly the conformational homogeneity of a protein sample is the fluorescence-based thermal-shift assay (Thermofluor). Here, a novel 96-condition screen for Thermofluor experiments is presented which consists of buffer and additive parts. The buffer screen comprises 23 different buffers and the additive screen includes small-molecule additives such as salts and nucleotide analogues. The utilization of small-molecule components which increase the thermal stability of a protein sample frequently results in a protein preparation of higher quality and quantity and ultimately also increases the chances of the protein crystallizing.
Garg, Shiwani; Mahajan, Pardeep; Thaman, Deepa; Monga, Prashant
2015-01-01
To compare dentinal damage caused by hand and rotary nickel-titanium instruments using ProTaper, K3 Endo, and Easy RaCe systems after root canal preparation. One hundred and fifty freshly extracted mandibular premolars were randomly divided into five experimental groups of 30 teeth each and biomechanical preparation was done: Group 1 with unprepared teeth; Group 2 were prepared with hand files; Group 3 with ProTaper rotary instruments; Group 4 with K3 rotary; Group 5 with Easy RaCe rotary instruments. Then, roots were cut horizontally at 3, 6, and 9 mm from apex and were viewed under stereomicroscope. The presence of dentinal defects was noted. Groups were analyzed with the Chi-square test. Significant difference was seen between groups. No defects were found in unprepared roots and those prepared with hand files. ProTaper, K3 rotary, and Easy RaCe preparations resulted in dentinal defects in 23.3%, 10%, and 16.7% of teeth, respectively. More defects were shown in coronal and middle sections, and no defect was seen in apical third. The present study revealed that use of rotary instruments could result in an increased chance for dentinal defects as compared to hand instrumentation.
Easy GROMACS: A Graphical User Interface for GROMACS Molecular Dynamics Simulation Package
NASA Astrophysics Data System (ADS)
Dizkirici, Ayten; Tekpinar, Mustafa
2015-03-01
GROMACS is a widely used molecular dynamics simulation package. Since it is a command driven program, it is difficult to use this program for molecular biologists, biochemists, new graduate students and undergraduate researchers who are interested in molecular dynamics simulations. To alleviate the problem for those researchers, we wrote a graphical user interface that simplifies protein preparation for a classical molecular dynamics simulation. Our program can work with various GROMACS versions and it can perform essential analyses of GROMACS trajectories as well as protein preparation. We named our open source program `Easy GROMACS'. Easy GROMACS can give researchers more time for scientific research instead of dealing with technical intricacies.
NASA Astrophysics Data System (ADS)
Venkatachalam, G.; Gautham Shankar, A.; Vijay, Kumar V.; Chandan, Byral R.; Prabaharan, G. P.; Raghav, Dasarath
2015-07-01
The polymer matrix composites attract many industrial applications due to its light weight, less cost and easy for manufacturing. In this paper, an attempt is made to prepare and study of the tensile strength of hybrid (two natural) fibers reinforced hybrid (Natural + Synthetic) polymer matrix composites. The samples were prepared with hybrid reinforcement consists of two different fibers such as jute and Gongura and hybrid polymer consists of polyester and cashew nut shell resins. The hybrid composites tensile strength is evaluated to study the influence of various fiber parameters on mechanical strength. The parameters considered here are the duration of fiber treatment, the concentration of alkali in fiber treatment and nature of fiber content in the composites.
RNA-Seq for Bacterial Gene Expression.
Poulsen, Line Dahl; Vinther, Jeppe
2018-06-01
RNA sequencing (RNA-seq) has become the preferred method for global quantification of bacterial gene expression. With the continued improvements in sequencing technology and data analysis tools, the most labor-intensive and expensive part of an RNA-seq experiment is the preparation of sequencing libraries, which is also essential for the quality of the data obtained. Here, we present a straightforward and inexpensive basic protocol for preparation of strand-specific RNA-seq libraries from bacterial RNA as well as a computational pipeline for the data analysis of sequencing reads. The protocol is based on the Illumina platform and allows easy multiplexing of samples and the removal of sequencing reads that are PCR duplicates. © 2018 by John Wiley & Sons, Inc. © 2018 John Wiley & Sons, Inc.
Xu, Sihong; Song, Aijing; Nie, Jianhui; Li, Xiuhua; Wang, Youchun
2010-10-01
Six HIV-1 viral load assays have been widely used in China. These include the Cobas Amplicor HIV-1 Monitor Version 1.5 ('Amplicor'), Cobas AmpliPrep/Cobas TaqMan HIV-1 test Version 1.0 ('CAP/CTM'), Versant HIV-1 RNA Version 3.0 (branched DNA [bDNA]-based assay; 'Versant bDNA'), Abbott RealTime HIV-1 assay ('Abbott RealTime'), NucliSens HIV-1 QT (nucleic acid sequence-based amplification assay; 'NucliSens NASBA'), and NucliSens EasyQ HIV-1 Version 1.1 ('EasyQ V1.1'). Recently, an updated version of EasyQ V1.1, NucliSens EasyQ HIV-1 Version 2.0 ('EasyQ V2.0') was introduced into China. It is important to evaluate the impact of HIV-1 genotypes on the updated assay compared with the other commercial available assays in China. A total of 175 plasma samples with different HIV-1 clades prevalent in China were collected from treatment-naïve patients. The viral loads of those samples were determined with the seven HIV-1 viral load assays, and the quantitative differences between them were evaluated. Overall, EasyQ V2.0 exhibited a significant correlation (R = 0.769-0.850, p ≤ 0.001) and high agreement (94.77-97.13%, using the Bland-Altman model) with the other six assays. Although no significant differences between EasyQ V2.0 and the other six assays were observed when quantifying clade B' samples, there were statistically significant differences between EasyQ V2.0 and the Amplicor, Versant bDNA, and Abbott RealTime assays when quantifying clade BC samples, and between EasyQ V2.0 and the Versant bDNA and Abbott RealTime assays when quantifying clade AE samples. For clade BC samples, the quantitative differences between EasyQ V2.0 and the Amplicor, Versant bDNA, and Abbott RealTime assays exceeded 0.5 log(10) IU/mL in approximately 50% of samples and exceeded 1 log(10) IU/mL in approximately 15% of samples. For clade AE samples, the quantitative differences between EasyQ V2.0 and the CAP/CTM, Versant bDNA, and Abbott RealTime assays exceeded 0.5 log(10) IU/mL in approximately 50% of samples, and the differences between EasyQ V2.0 and CAP/CTM exceeded 1 log(10) IU/mL in approximately 15% of samples. Genotypes may affect the quantification of HIV-1 RNA, especially in clade BC samples with respect to EasyQ V2.0 and the Amplicor, Versant bDNA, or Abbott RealTime assays, and in clade AE samples with respect to EasyQ V2.0 and the Versant bDNA or Abbott RealTime assays. It is therefore strongly suggested that, where possible, the HIV-1 viral load in infected patients be quantified at follow-up by the same version of the same assay that was used initially.
Microvolume protein concentration determination using the NanoDrop 2000c spectrophotometer.
Desjardins, Philippe; Hansen, Joel B; Allen, Michael
2009-11-04
Traditional spectrophotometry requires placing samples into cuvettes or capillaries. This is often impractical due to the limited sample volumes often used for protein analysis. The Thermo Scientific NanoDrop 2000c Spectrophotometer solves this issue with an innovative sample retention system that holds microvolume samples between two measurement surfaces using the surface tension properties of liquids, enabling the quantification of samples in volumes as low as 0.5-2 microL. The elimination of cuvettes or capillaries allows real time changes in path length, which reduces the measurement time while greatly increasing the dynamic range of protein concentrations that can be measured. The need for dilutions is also eliminated, and preparations for sample quantification are relatively easy as the measurement surfaces can be simply wiped with laboratory wipe. This video article presents modifications to traditional protein concentration determination methods for quantification of microvolume amounts of protein using A280 absorbance readings or the BCA colorimetric assay.
Sudore, Rebecca L; Boscardin, John; Feuz, Mariko A; McMahan, Ryan D; Katen, Mary T; Barnes, Deborah E
2017-08-01
Documentation rates of patients' medical wishes are often low. It is unknown whether easy-to-use, patient-facing advance care planning (ACP) interventions can overcome barriers to planning in busy primary care settings. To compare the efficacy of an interactive, patient-centered ACP website (PREPARE) with an easy-to-read advance directive (AD) to increase planning documentation. This was a comparative effectiveness randomized clinical trial from April 2013 to July 2016 conducted at multiple primary care clinics at the San Francisco VA Medical Center. Inclusion criteria were age of a least 60 years; at least 2 chronic and/or serious conditions; and 2 or more primary care visits; and 2 or more additional clinic, hospital, or emergency room visits in the last year. Participants were randomized to review PREPARE plus an easy-to-read AD or the AD alone. There were no clinician and/or system-level interventions or education. Research staff were blinded for all follow-up measurements. The primary outcome was new ACP documentation (ie, legal forms and/or discussions) at 9 months. Secondary outcomes included patient-reported ACP engagement at 1 week, 3 months, and 6 months using validated surveys of behavior change process measures (ie, 5-point knowledge, self-efficacy, readiness scales) and action measures (eg, surrogate designation, using a 0-25 scale). We used intention-to-treat, mixed-effects logistic and linear regression, controlling for time, health literacy, race/ethnicity, baseline ACP, and clustering by physician. The mean (SD) age of 414 participants was 71 (8) years, 38 (9%) were women, 83 (20%) had limited literacy, and 179 (43%) were nonwhite. No participant characteristic differed significantly among study arms at baseline. Retention at 6 months was 90%. Advance care planning documentation 6 months after enrollment was higher in the PREPARE arm vs the AD-alone arm (adjusted 35% vs 25%; odds ratio, 1.61 [95% CI, 1.03-2.51]; P = .04). PREPARE also resulted in higher self-reported ACP engagement at each follow-up, including higher process and action scores; P <.001 at each follow-up). Easy-to-use, patient-facing ACP tools, without clinician- and/or system-level interventions, can increase planning documentation 25% to 35%. Combining the PREPARE website with an easy-to-read AD resulted in higher planning documentation than the AD alone, suggesting that PREPARE may increase planning documentation with minimal health care system resources. clinicaltrials.gov Identifier: NCT01550731.
Shore Stabilization with Salt Marsh Vegetation.
1983-01-01
seedlings - more expensive to grow and plant, more awkward to handle and transport, but relatively easy to produce. (3) Plugs - most expensive to...to sprigs, particularly if trans- planted late in the growing season. Pot-grown seedlings are relatively easy to produce but considerably more...transplanted late in the growing season. Pot-grown seedlings are relatively easy to produce but considerably more expensive than sprigs (Fig. 25). To prepare
Wei, Shih-Chun; Fan, Shen; Lien, Chia-Wen; Unnikrishnan, Binesh; Wang, Yi-Sheng; Chu, Han-Wei; Huang, Chih-Ching; Hsu, Pang-Hung; Chang, Huan-Tsung
2018-03-20
A graphene oxide (GO) nanosheet-modified N + -nylon membrane (GOM) has been prepared and used as an extraction and spray-ionization substrate for robust mass spectrometric detection of malachite green (MG), a highly toxic disinfectant in liquid samples and fish meat. The GOM is prepared by self-deposition of GO thin film onto an N + -nylon membrane, which has been used for efficient extraction of MG in aquaculture water samples or homogenized fish meat samples. Having a dissociation constant of 2.17 × 10 -9 M -1 , the GOM allows extraction of approximately 98% of 100 nM MG. Coupling of the GOM-spray with an ion-trap mass spectrometer allows quantitation of MG in aquaculture freshwater and seawater samples down to nanomolar levels. Furthermore, the system possesses high selectivity and sensitivity for the quantitation of MG and its metabolite (leucomalachite green) in fish meat samples. With easy extraction and efficient spray ionization properties of GOM, this membrane spray-mass spectrometry technique is relatively simple and fast in comparison to the traditional LC-MS/MS methods for the quantitation of MG and its metabolite in aquaculture products. Copyright © 2017 Elsevier B.V. All rights reserved.
Jiang, Y; Li, X; Xu, J; Pan, C; Zhang, J; Niu, W
2009-06-01
A method based on a QuEChERS (quick, easy, cheap, effective, rugged, safe) sample preparation method and gas chromatography with mass spectrometric detection by selected ion monitoring (GC/MS-SIM) was developed for simultaneous determination of 77 pesticide residues in wine. An extraction of 10 ml of sample with acetonitrile followed by liquid-liquid partition formed by the addition of 4 g MgSO(4) and 3 g NaCl was applied in the sample preparation. The clean-up was carried out by applying dispersive solid-phase with 150 mg MgSO(4) as well as 50 mg primary secondary amine (PSA). One quantitation ion and at least two identification ions were selected in the analytical method for each pesticide compound by GC/MS. The recovery data were obtained by spiking blank samples at two concentration levels (0.05 and 0.2 mg l(-1)). The recoveries of all pesticides were in the range 70-110%, with intra-day precision of less than 15%, and the inter-day precision of less than 22% and 15% for 0.05 and 0.2 mg l(-1) fortification levels, respectively. Linearity was between 0.02 and 2 mg l(-1) with determination coefficients (R(2)) greater than 0.98 for all compounds. The limits of quantification (LOQs) for the 77 pesticides ranged from 0.003 to 0.05 mg l(-1). This method was applied for routine analysis in market products.
Wu, Yao; Chen, Lei; Long, Xuwei; Zhang, Xiaolin; Pan, Bingcai; Qian, Jieshu
2018-04-05
It is of great practical importance but rarely reported to design a multifunctional scavenger for water purification. In this study, we describe a sophisticated preparation of an inorganic/organic composite sample for the simultaneous removal of anionic dyes and metal ions, as well as disinfection. The sample has a stable structure formed by the covalent connection between a magnetic silica (MS) core and a polyethylenimine derived quaternary ammonium compound (QAC) corona. We characterized the sample in details by SEM, TEM, EDX, FT-IR, XRD, TGA, VSM, and zeta potential. Our QAC-MS sample exhibited superior performance and reusability in the disinfection and adsorption experiments towards acid fuchsin and Cu 2+ . With the virtue of easy separation from solution, our sample should be an ideal candidate for water purification application. Copyright © 2017 Elsevier B.V. All rights reserved.
Thomin, Jean; Aubin, Guillaume Ghislain; Foubert, Fabrice; Corvec, Stéphane
2015-08-01
In this study, we developed and compared four protocols to prepare a bacterial pellet from 944 positive blood cultures for direct MALDI-TOF mass spectrometry Vitek® MS analysis. Protocol 4, tested on 200 monomicrobial samples, allowed 83% of bacterial identification. This easy, fast, cheap and accurate method is promising in daily practice, especially to limit broad range antibiotic treatment. Copyright © 2015 Elsevier B.V. All rights reserved.
Leak, Tashara M; Aasand, Taylor A; Vickers, Zata; Reicks, Marla
2018-05-01
The purpose of this study was to understand adolescents' from low-income households perceptions of their involvement in home food preparation, reasons underlying the extent to which they were involved, and positive and negative consequences associated with their involvement. Semistructured interviews were conducted with a convenience sample of 19 adolescents (13-18 years). Audio-recorded interviews were transcribed verbatim. Themes were identified using grounded theory and the constant comparative method. Eight adolescents described cooking as a primary responsibility due to adult work and family schedules, age, gender, and/or cultural expectations. They were typically preparing food for themselves and their family without assistance, and making decisions about what was prepared. They identified positive and negative consequences including enjoyment and satisfaction, as well as stress and less time for other activities. Eleven adolescents mostly assisted the primary food preparer, with little input in deciding what was prepared. They identified benefits such as enjoyment and family interaction. Foods prepared by many adolescents tended to be quick and easy to prepare foods. Future studies should investigate the relationship between adultified cooking responsibilities, diet quality, and health. Also, cooking education for adolescents needs to address how to prepare a healthy family meal on a budget.
NASA Astrophysics Data System (ADS)
Wiśniewska, Paulina; Boqué, Ricard; Borràs, Eva; Busto, Olga; Wardencki, Waldemar; Namieśnik, Jacek; Dymerski, Tomasz
2017-02-01
Headspace mass-spectrometry (HS-MS), mid infrared (MIR) and UV-vis spectroscopy were used to authenticate whisky samples from different origins and ways of production ((Irish, Spanish, Bourbon, Tennessee Whisky and Scotch). The collected spectra were processed with partial least-squares discriminant analysis (PLS-DA) to build the classification models. In all cases the five groups of whiskies were distinguished, but the best results were obtained by HS-MS, which indicates that the biggest differences between different types of whisky are due to their aroma. Differences were also found inside groups, showing that not only raw material is important to discriminate samples but also the way of their production. The methodology is quick, easy and does not require sample preparation.
Vega, Victor; Ibabe, Angel; Jaafar, Miriam; Asenjo, Agustina
2018-01-01
In this article, the magnetic properties of hexagonally ordered antidot arrays made of Dy13Fe87 alloy are studied and compared with corresponding ones of continuous thin films with the same compositions and thicknesses, varying between 20 nm and 50 nm. Both samples, the continuous thin films and antidot arrays, were prepared by high vacuum e-beam evaporation of the alloy on the top-surface of glass and hexagonally self-ordered nanoporous alumina templates, which serve as substrates, respectively. By using a highly sensitive magneto-optical Kerr effect (MOKE) and vibrating sample magnetometer (VSM) measurements an interesting phenomenon has been observed, consisting in the easy magnetization axis transfer from a purely in-plane (INP) magnetic anisotropy to out-of-plane (OOP) magnetization. For the 30 nm film thickness we have measured the volume hysteresis loops by VSM with the easy magnetization axis lying along the OOP direction. Using magnetic force microscopy measurements (MFM), there is strong evidence to suggest that the formation of magnetic domains with OOP magnetization occurs in this sample. This phenomenon can be of high interest for the development of novel magnetic and magneto-optic perpendicular recording patterned media based on template-assisted deposition techniques. PMID:29642476
Salaheldeen, Mohamed; Vega, Victor; Ibabe, Angel; Jaafar, Miriam; Asenjo, Agustina; Fernandez, Agustin; Prida, Victor M
2018-04-08
In this article, the magnetic properties of hexagonally ordered antidot arrays made of Dy 13 Fe 87 alloy are studied and compared with corresponding ones of continuous thin films with the same compositions and thicknesses, varying between 20 nm and 50 nm. Both samples, the continuous thin films and antidot arrays, were prepared by high vacuum e-beam evaporation of the alloy on the top-surface of glass and hexagonally self-ordered nanoporous alumina templates, which serve as substrates, respectively. By using a highly sensitive magneto-optical Kerr effect (MOKE) and vibrating sample magnetometer (VSM) measurements an interesting phenomenon has been observed, consisting in the easy magnetization axis transfer from a purely in-plane (INP) magnetic anisotropy to out-of-plane (OOP) magnetization. For the 30 nm film thickness we have measured the volume hysteresis loops by VSM with the easy magnetization axis lying along the OOP direction. Using magnetic force microscopy measurements (MFM), there is strong evidence to suggest that the formation of magnetic domains with OOP magnetization occurs in this sample. This phenomenon can be of high interest for the development of novel magnetic and magneto-optic perpendicular recording patterned media based on template-assisted deposition techniques.
A novel hybridization approach for detection of citrus viroids.
Murcia, N; Serra, P; Olmos, A; Duran-Vila, N
2009-04-01
Citrus plants are natural hosts of several viroid species all belonging to the family Pospiviroidae. Previous attempts to detect viroids from field-grown species and cultivars yielded erratic results unless analyses were performed using Etrog citron a secondary bio-amplification host. To overcome the use of Etrog citron a number of RT-PCR approaches have been proposed with different degrees of success. Here we report the suitability of an easy to handle northern hybridization protocol for viroid detection of samples collected from field-grown citrus species and cultivars. The protocol involves: (i) Nucleic acid preparations from bark tissue samples collected from field-grown trees regardless of the growing season and storage conditions; (ii) Separation in 5% PAGE or 1% agarose, blotting to membrane and fixing; (iii) Hybridization with viroid-specific DIG-labelled probes and detection with anti-DIG-alkaline phosphatase conjugate and autoradiography with the CSPD substrate. The method has been tested with viroid-infected trees of sweet orange, lemon, mandarin, grapefruit, sour orange, Swingle citrumello, Tahiti lime and Mexican lime. This novel hybridization approach is extremely sensitive, easy to handle and shortens the time needed for reliable viroid indexing tests. The suitability of PCR generated DIG-labelled probes and the sensitivity achieved when the samples are separated and blotted from non-denaturing gels are discussed.
Gao, Yan; Sun, Ying; Jiang, Chunzhu; Yu, Xi; Wang, Yuanpeng; Zhang, Hanqi; Song, Daqian
2013-01-01
An analytical method was developed for the extraction and determination of pyrethroid pesticide residues in tobacco. The modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method was applied for preparing samples. In this study, methyl cyanide (MeCN)-saturated salt aqueous was used as the two-phase extraction solvent for the first time, and a vortex shaker was used for the simultaneous shaking and concentration of the analytes. The effects of experimental parameters on extraction and clean-up efficiency were investigated and optimized. The analytes were determined by gas chromatography-mass spectrometry-selected ion monitoring (GC-MS-SIM). The obtained recoveries of the analytes at three different fortification levels were 76.85-114.1% and relative standard deviations (RSDs) were lower than 15.7%. The limits of quantification (LOQs) were from 1.28 to 26.6 μg kg(-1). This method was also applied to the analysis of actual commercial tobacco products and the analytical results were satisfactory.
Liang, Yu; Zhang, Lihua; Zhang, Yukui
2013-03-01
Capillary liquid chromatography (cLC) has great potential for protein and peptide separation, with advantages of high efficiency, high resolution, low sample consumption, and high sensitivity when coupled with mass spectrometry. In recent years, monoliths have been widely used as the stationary phases for capillary columns, owing to easy preparation, high permeability, fast mass transfer, and low backpressure. This review summarizes recent advances (2007-2012) in monolithic columns for protein and peptide separation by cLC. After a brief introduction on the preparation of monolithic capillary columns, the emphasis of this review is focused on the recent application of such columns for protein and peptide separation by cLC. Furthermore, the challenges and potential hot points of monolithic capillary columns in the future are discussed.
Jiang, Qianzhou; Chen, Minle; Ding, Jiangfeng
2013-12-01
This study aimed to investigate the interaction of current one-bottle self-etching adhesives and Er:YAG laser with dentin using a tensile bond strength (TBS) test and scanning electron microscopy (SEM) in vitro. Two hundred and thirteen dentin discs were randomly distributed to the Control Group using bur cutting and to the Laser Group using an Er:YAG laser (200 mJ, VSP, 20 Hz). The following adhesives were investigated: one two-step total-etch adhesive [Prime & Bond NT (Dentsply)] and four one-step self-etch adhesives [G-Bond plus (GC), XENO V (Dentsply), iBond Self Etch (Heraeus) and Adper Easy One (3 M ESPE)]. Samples were restored with composite resin, and after 24-hour storage in distilled water, subjected to the TBS test. For morphological analysis, 12 dentin specimens were prepared for SEM. No significant differences were found between the control group and laser group (p = 0.899); dentin subjected to Prime & Bond NT, XENOV and Adper Easy One produced higher TBS. In conclusion, this study indicates that Er:YAG laser-prepared dentin can perform as well as bur on TBS, and some of the one-step one-bottle adhesives are comparable to the total-etch adhesives in TBS on dentin.
Production and stability of mechanochemically exfoliated graphene in water and culture media
NASA Astrophysics Data System (ADS)
León, V.; González-Domínguez, J. M.; Fierro, J. L. G.; Prato, M.; Vázquez, E.
2016-07-01
The preparation of graphene suspensions in water, without detergents or any other additives is achieved using freeze-dried graphene powders, produced by mechanochemical exfoliation of graphite. These powders of graphene can be safely stored or shipped, and promptly dissolved in aqueous media. The suspensions are relatively stable in terms of time, with a maximum loss of ~25% of the initial concentration at 2 h. This work provides an easy and general access to aqueous graphene suspensions of chemically non-modified graphene samples, an otherwise (almost) impossible task to achieve by other means. A detailed study of the stability of the relative dispersions is also reported.The preparation of graphene suspensions in water, without detergents or any other additives is achieved using freeze-dried graphene powders, produced by mechanochemical exfoliation of graphite. These powders of graphene can be safely stored or shipped, and promptly dissolved in aqueous media. The suspensions are relatively stable in terms of time, with a maximum loss of ~25% of the initial concentration at 2 h. This work provides an easy and general access to aqueous graphene suspensions of chemically non-modified graphene samples, an otherwise (almost) impossible task to achieve by other means. A detailed study of the stability of the relative dispersions is also reported. Electronic supplementary information (ESI) available: A video showing the dispersion process, the N 1s XPS spectrum of BMG, image of the graphite test in CCM, and the characterization of the GO employed. See DOI: 10.1039/c6nr03246j
NASA Astrophysics Data System (ADS)
Liu, Yongliang; Chen, Yud-Ren; Nou, Xiangwu; Chao, Kaunglin
2007-09-01
Rapid and routine identification of foodborne bacteria are considerably important, because of bio- / agro- terrorism threats, public health concerns, and economic loss. Conventional, PCR, and immunoassay methods for the detection of bacteria are generally time-consuming, chemical reagent necessary and multi-step procedures. Fast microbial detection requires minimal sample preparation, permits the routine analysis of large numbers of samples with negligible reagent costs, and is easy to operate. Therefore, we have developed silver colloidal nanoparticle based surface-enhanced Raman scattering (SERS) spectroscopy as a potential tool for the rapid and routine detection of E. coli and L. monocytogenes. This study presents the further results of our examination on S. typhimonium, one of the most commonly outbreak bacteria, for the characteristic bands and subsequent identification.
Jankowski, Stéphane; Currie-Fraser, Erica; Xu, Licen; Coffa, Jordy
2008-09-01
Annotated DNA samples that had been previously analyzed were tested using multiplex ligation-dependent probe amplification (MLPA) assays containing probes targeting BRCA1, BRCA2, and MMR (MLH1/MSH2 genes) and the 9p21 chromosomal region. MLPA polymerase chain reaction products were separated on a capillary electrophoresis platform, and the data were analyzed using GeneMapper v4.0 software (Applied Biosystems, Foster City, CA). After signal normalization, loci regions that had undergone deletions or duplications were identified using the GeneMapper Report Manager and verified using the DyeScale functionality. The results highlight an easy-to-use, optimal sample preparation and analysis workflow that can be used for both small- and large-scale studies.
Wiśniewska, Paulina; Boqué, Ricard; Borràs, Eva; Busto, Olga; Wardencki, Waldemar; Namieśnik, Jacek; Dymerski, Tomasz
2017-02-15
Headspace mass-spectrometry (HS-MS), mid infrared (MIR) and UV-vis spectroscopy were used to authenticate whisky samples from different origins and ways of production ((Irish, Spanish, Bourbon, Tennessee Whisky and Scotch). The collected spectra were processed with partial least-squares discriminant analysis (PLS-DA) to build the classification models. In all cases the five groups of whiskies were distinguished, but the best results were obtained by HS-MS, which indicates that the biggest differences between different types of whisky are due to their aroma. Differences were also found inside groups, showing that not only raw material is important to discriminate samples but also the way of their production. The methodology is quick, easy and does not require sample preparation. Copyright © 2016 Elsevier B.V. All rights reserved.
Microvolume Protein Concentration Determination using the NanoDrop 2000c Spectrophotometer
Desjardins, Philippe; Hansen, Joel B.; Allen, Michael
2009-01-01
Traditional spectrophotometry requires placing samples into cuvettes or capillaries. This is often impractical due to the limited sample volumes often used for protein analysis. The Thermo Scientific NanoDrop 2000c Spectrophotometer solves this issue with an innovative sample retention system that holds microvolume samples between two measurement surfaces using the surface tension properties of liquids, enabling the quantification of samples in volumes as low as 0.5-2 μL. The elimination of cuvettes or capillaries allows real time changes in path length, which reduces the measurement time while greatly increasing the dynamic range of protein concentrations that can be measured. The need for dilutions is also eliminated, and preparations for sample quantification are relatively easy as the measurement surfaces can be simply wiped with laboratory wipe. This video article presents modifications to traditional protein concentration determination methods for quantification of microvolume amounts of protein using A280 absorbance readings or the BCA colorimetric assay. PMID:19890248
Wastewater Biosolid Composting Optimization Based on UV-VNIR Spectroscopy Monitoring
Temporal-Lara, Beatriz; Melendez-Pastor, Ignacio; Gómez, Ignacio; Navarro-Pedreño, Jose
2016-01-01
Conventional wastewater treatment generates large amounts of organic matter–rich sludge that requires adequate treatment to avoid public health and environmental problems. The mixture of wastewater sludge and some bulking agents produces a biosolid to be composted at adequate composting facilities. The composting process is chemically and microbiologically complex and requires an adequate aeration of the biosolid (e.g., with a turner machine) for proper maturation of the compost. Adequate (near) real-time monitoring of the compost maturity process is highly difficult and the operation of composting facilities is not as automatized as other industrial processes. Spectroscopic analysis of compost samples has been successfully employed for compost maturity assessment but the preparation of the solid compost samples is difficult and time-consuming. This manuscript presents a methodology based on a combination of a less time-consuming compost sample preparation and ultraviolet, visible and short-wave near-infrared spectroscopy. Spectroscopic measurements were performed with liquid compost extract instead of solid compost samples. Partial least square (PLS) models were developed to quantify chemical fractions commonly employed for compost maturity assessment. Effective regression models were obtained for total organic matter (residual predictive deviation—RPD = 2.68), humification ratio (RPD = 2.23), total exchangeable carbon (RPD = 2.07) and total organic carbon (RPD = 1.66) with a modular and cost-effective visible and near infrared (VNIR) spectroradiometer. This combination of a less time-consuming compost sample preparation with a versatile sensor system provides an easy-to-implement, efficient and cost-effective protocol for compost maturity assessment and near-real-time monitoring. PMID:27854280
Wastewater Biosolid Composting Optimization Based on UV-VNIR Spectroscopy Monitoring.
Temporal-Lara, Beatriz; Melendez-Pastor, Ignacio; Gómez, Ignacio; Navarro-Pedreño, Jose
2016-11-15
Conventional wastewater treatment generates large amounts of organic matter-rich sludge that requires adequate treatment to avoid public health and environmental problems. The mixture of wastewater sludge and some bulking agents produces a biosolid to be composted at adequate composting facilities. The composting process is chemically and microbiologically complex and requires an adequate aeration of the biosolid (e.g., with a turner machine) for proper maturation of the compost. Adequate (near) real-time monitoring of the compost maturity process is highly difficult and the operation of composting facilities is not as automatized as other industrial processes. Spectroscopic analysis of compost samples has been successfully employed for compost maturity assessment but the preparation of the solid compost samples is difficult and time-consuming. This manuscript presents a methodology based on a combination of a less time-consuming compost sample preparation and ultraviolet, visible and short-wave near-infrared spectroscopy. Spectroscopic measurements were performed with liquid compost extract instead of solid compost samples. Partial least square (PLS) models were developed to quantify chemical fractions commonly employed for compost maturity assessment. Effective regression models were obtained for total organic matter (residual predictive deviation-RPD = 2.68), humification ratio (RPD = 2.23), total exchangeable carbon (RPD = 2.07) and total organic carbon (RPD = 1.66) with a modular and cost-effective visible and near infrared (VNIR) spectroradiometer. This combination of a less time-consuming compost sample preparation with a versatile sensor system provides an easy-to-implement, efficient and cost-effective protocol for compost maturity assessment and near-real-time monitoring.
Schlee, Claudia; Markova, Mariya; Schrank, Julia; Laplagne, Fanette; Schneider, Rüdiger; Lachenmeier, Dirk W
2013-05-15
Substituted imidazoles recently came under scrutiny as they may be indirectly introduced into cola beverages via the use of class IV (E150d) caramel colours and may pose health hazards. A LC/MS/MS method was developed for determining 2- and 4-methylimidazole (2-MI, 4-MI) and 2-acetyl-4-(1,2,3,4)-tetrahydroxybutylimidazole (THI) in beverages and caramel colours. The method is very rapid and easy to conduct as it requires only dilution in eluent for sample preparation. For 4-MI, the recovery was between 94 and 102% for spiked cola samples. The limit of detection was 2μg/L in the measuring solution (corresponding to 40μg/L for cola samples diluted 1:20 during sample preparation). 97 cola samples and 13 caramel colours from Germany and France were analysed. From the 3 analytes, only 4-MI was found in the samples with very varying concentrations (non quantifiable traces to 0.6mg/L in colas and 175-658mg/kg in E150d). The exposure for cola drinkers in worst case scenarios is estimated to be 2-5μg/kg bodyweight/day, which is judged as being only a low risk for public health. Copyright © 2012 Elsevier B.V. All rights reserved.
Stable isotope dimethyl labelling for quantitative proteomics and beyond
Hsu, Jue-Liang; Chen, Shu-Hui
2016-01-01
Stable-isotope reductive dimethylation, a cost-effective, simple, robust, reliable and easy-to- multiplex labelling method, is widely applied to quantitative proteomics using liquid chromatography-mass spectrometry. This review focuses on biological applications of stable-isotope dimethyl labelling for a large-scale comparative analysis of protein expression and post-translational modifications based on its unique properties of the labelling chemistry. Some other applications of the labelling method for sample preparation and mass spectrometry-based protein identification and characterization are also summarized. This article is part of the themed issue ‘Quantitative mass spectrometry’. PMID:27644970
Wu, Zengnan; Khan, Mashooq; Mao, Sifeng; Lin, Ling; Lin, Jin-Ming
2018-05-01
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a fast analysis tool for the detection of a wide range of analytes. However, heterogeneous distribution of matrix/analyte cocrystal, variation in signal intensity and poor experimental reproducibility at different locations of the same spot means difficulty in quantitative analysis. In this work, carbon nanotubes (CNTs) were employed as adsorbent for analyte cum matrix on a conductive porous membrane as a novel mass target plate. The sample pretreatment step was achieved by enrichment and dead-end filtration and dried by a solid-liquid separation. This approach enables the homogeneous distribution of analyte in the matrix, good shot-to-shot reproducibility in signals and quantitative detection of peptide and protein at different concentrations with correlation coefficient (R 2 ) of 0.9920 and 0.9909, respectively. The simple preparation of sample in a short time, uniform distribution of analyte, easy quantitative detection, and high reproducibility makes this technique useful and may diversify the application of MALDI-MS for quantitative detection of a variety of proteins. Copyright © 2018 Elsevier B.V. All rights reserved.
Tangchaikeeree, Tienrat; Polpanich, Duangporn; Elaissari, Abdelhamid; Jangpatarapongsa, Kulachart
2017-10-01
Colloidal magnetic particles (MPs) have been developed in association with molecular diagnosis for several decades. MPs have the great advantage of easy manipulation using a magnet. In nucleic acid detection, these particles can act as a capture support for rapid and simple biomolecule separation. The surfaces of MPs can be modified by coating with various polymer materials to provide functionalization for different applications. The use of MPs enhances the sensitivity and specificity of detection due to the specific activity on the surface of the particles. Practical applications of MPs demonstrate greater efficiency than conventional methods. Beyond traditional detection, MPs have been successfully adopted as a smart carrier in microfluidic and lab-on-a-chip biosensors. The versatility of MPs has enabled their integration into small single detection units. MPs-based biosensors can facilitate rapid and highly sensitive detection of very small amounts of a sample. In this review, the application of MPs to the detection of nucleic acids, from sample preparation to analytical readout systems, is described. State-of-the-art integrated microsystems containing microfluidic and lab-on-a-chip biosensors for the nucleic acid detection are also addressed. Copyright © 2017 Elsevier B.V. All rights reserved.
[Measurement of the status of trace elements in cattle using liver biopsy samples].
Ouweltjes, W; de Zeeuw, A C; Moen, A; Counotte, G H M
2007-02-01
Serum, plasma, or urine samples are usually used for the measurement of the trace elements copper; zinc, iron, selenium, because these samples are easy to obtain; however; these samples are not always appropriate. For example, it is not possible to measure molybdenum, the major antagonist of copper; in blood or urine. Therefore measurement of trace elements in liver tissue is considered the gold standard. For the assessment of selenium the method of choice remains determination of glutathion peroxidase in erythrocytes and for the assessment of magnesium determination of magnesium in urine. We determined the accuracy and repeatability of measuring trace elements in liver biopsies and whole liver homogenates. The levels of trace elements measured were similar in both preparations (92% agreement). Liver biopsy in live animals is a relatively simple procedure but not common in The Netherlands. Reference levels of trace elements, classified as too low, low, adequate, high, and too high, were established on the basis of our research and information in the literature. In a second study we investigated the practical aspects of obtaining liver tissue samples and their use. Samples were collected from cattle on a commercial dairy farm. Liver biopsy provided additional information to that obtained from serum and urine samples. We prepared a biopsy protocol and a test package, which we tested on 14 farms where an imbalance of trace minerals was suspected. Biopsy samples taken from 4 to 6 animals revealed extreme levels of trace elements.
Liu, L; Luo, Y; Accensi, F; Ganges, L; Rodríguez, F; Shan, H; Ståhl, K; Qiu, H-J; Belák, S
2017-10-01
African swine fever (ASF) and classical swine fever (CSF) are two highly infectious transboundary animal diseases (TADs) that are serious threats to the pig industry worldwide, including in China, the world's largest pork producer. In this study, a duplex real-time PCR assay was developed for the rapid detection and differentiation of African swine fever virus (ASFV) and classical swine fever virus (CSFV). The assay was performed on a portable, battery-powered PCR thermocycler with a low sample throughput (termed as 'T-COR4 assay'). The feasibility and reliability of the T-COR4 assay as a possible field method was investigated by testing clinical samples collected in China. When evaluated with reference materials or samples from experimental infections, the assay performed in a reliable manner, producing results comparable to those obtained from stationary PCR platforms. Of 59 clinical samples, 41 had results identical to a two-step CSFV real-time PCR assay. No ASFV was detected in these samples. The T-COR4 assay was technically easy to perform and produced results within 3 h, including sample preparation. In combination with a simple sample preparation method, the T-COR4 assay provides a new tool for the field diagnosis and differentiation of ASF and CSF, which could be of particular value in remote areas. © 2016 Blackwell Verlag GmbH.
Smart, Kathleen F; Aggio, Raphael B M; Van Houtte, Jeremy R; Villas-Bôas, Silas G
2010-09-01
This protocol describes an analytical platform for the analysis of intra- and extracellular metabolites of microbial cells (yeast, filamentous fungi and bacteria) using gas chromatography-mass spectrometry (GC-MS). The protocol is subdivided into sampling, sample preparation, chemical derivatization of metabolites, GC-MS analysis and data processing and analysis. This protocol uses two robust quenching methods for microbial cultures, the first of which, cold glycerol-saline quenching, causes reduced leakage of intracellular metabolites, thus allowing a more reliable separation of intra- and extracellular metabolites with simultaneous stopping of cell metabolism. The second, fast filtration, is specifically designed for quenching filamentous micro-organisms. These sampling techniques are combined with an easy sample-preparation procedure and a fast chemical derivatization reaction using methyl chloroformate. This reaction takes place at room temperature, in aqueous medium, and is less prone to matrix effect compared with other derivatizations. This protocol takes an average of 10 d to complete and enables the simultaneous analysis of hundreds of metabolites from the central carbon metabolism (amino and nonamino organic acids, phosphorylated organic acids and fatty acid intermediates) using an in-house MS library and a data analysis pipeline consisting of two free software programs (Automated Mass Deconvolution and Identification System (AMDIS) and R).
Cabral, E C; Sevart, L; Spindola, H M; Coelho, M B; Sousa, I M O; Queiroz, N C A; Foglio, M A; Eberlin, M N; Riveros, J M
2013-02-01
The oil obtained from Pterodon pubescens (Leguminosae) seeds are known to display anti-cancer, anti-dermatogenic and anti-nociceptive activitiy. Phytochemical studies have demonstrated that its main constituents are diterpenoids with voucapan skeletons. Considering the potential biological activities of the oil, rapid and efficient methods for assessing its quality would facilitate certification and quality control. To develop a direct mass spectrometric fingerprinting method for the P. pubescens seed oil that would focus on the major diterpenoids constituents, enabling quality control, origin certification and recognition of marker species in commercially available products. Two techniques were used: (i) direct infusion electrospray ionisation (ESI) mass spectrometry after solvent extraction and dilution and (ii) ambient desorption/ionisation via easy ambient sonic-spray ionisation, EASI(+)-MS, performed directly on the seed surface or at a paper surface imprinted with the oil. From a combination of ESI-MS, HRESI-MS and ESI-MS/MS data, 12 diterpenes were characterised, and typical profiles were obtained for the oil extract or the crude oil via both ESI-MS and EASI-MS. These techniques require no or very simple sample preparation protocols and the whole analytical processes with spectra acquisition take just a few minutes. Both techniques, but particularly EASI-MS, provide simple, fast and efficient MS fingerprinting methodologies to characterise the P. pubescens oil with typical (di)terpene profiles being applicable to quality control and certification of authenticity and origin. Copyright © 2012 John Wiley & Sons, Ltd.
Wood, Jessica L; Steiner, Robert R
2011-06-01
Forensic analysis of pharmaceutical preparations requires a comparative analysis with a standard of the suspected drug in order to identify the active ingredient. Purchasing analytical standards can be expensive or unattainable from the drug manufacturers. Direct Analysis in Real Time (DART™) is a novel, ambient ionization technique, typically coupled with a JEOL AccuTOF™ (accurate mass) mass spectrometer. While a fast and easy technique to perform, a drawback of using DART™ is the lack of component separation of mixtures prior to ionization. Various in-house pharmaceutical preparations were purified using thin-layer chromatography (TLC) and mass spectra were subsequently obtained using the AccuTOF™- DART™ technique. Utilizing TLC prior to sample introduction provides a simple, low-cost solution to acquiring mass spectra of the purified preparation. Each spectrum was compared against an in-house molecular formula list to confirm the accurate mass elemental compositions. Spectra of purified ingredients of known pharmaceuticals were added to an in-house library for use as comparators for casework samples. Resolving isomers from one another can be accomplished using collision-induced dissociation after ionization. Challenges arose when the pharmaceutical preparation required an optimized TLC solvent to achieve proper separation and purity of the standard. Purified spectra were obtained for 91 preparations and included in an in-house drug standard library. Primary standards would only need to be purchased when pharmaceutical preparations not previously encountered are submitted for comparative analysis. TLC prior to DART™ analysis demonstrates a time efficient and cost saving technique for the forensic drug analysis community. Copyright © 2011 John Wiley & Sons, Ltd. Copyright © 2011 John Wiley & Sons, Ltd.
An Easy Method for Preparing Presentation Slides.
ERIC Educational Resources Information Center
Wright, Norman A.; Blevins, Dennis D.
1984-01-01
Describes a simplified method of preparing 35mm projection slides with a minimum of equipment and expertise. The quality of these slides compares favorably to professionally produced diazo slides. Twenty-five slides can easily be prepared in less than three hours. Material cost per slide is comparable to professional color slide processing. (JN)
NASA Astrophysics Data System (ADS)
Zheng, Zhoujun; Gao, Qiuming
Hierarchical porous carbons are prepared by an easy one-step process of carbonization and activation derived from phenol-formaldehyde resins, in which potassium hydroxide acts as both the catalyst of polymerization and the activation reagent. The simple one-step preparation saves the cost of carbons and leads to high yield. The porous carbons have high surface areas with abundant pore structures. The plenty of micropores and small mesopores increase the capacitance and make the electrolyte ions diffuse fast into the pores. These hierarchical porous carbons show high performance for supercapacitors possessing of the optimized capacitance of 234 F g -1 in aqueous electrolyte and 137 F g -1 in organic electrolyte with high capacitive retention.
NASA Astrophysics Data System (ADS)
Zhang, Tian-Yu; Wang, Qian; Deng, Ning-Qin; Zhao, Hai-Ming; Wang, Dan-Yang; Yang, Zhen; Liu, Ying; Yang, Yi; Ren, Tian-Ling
2017-09-01
In this paper, we have developed a high-performance graphene electrothermal actuator (ETA). The fabrication method is easy, fast, environmentally friendly, and suitable for preparing both large-size and miniature graphene ETAs. When applied with the driving voltage of 65 V, the graphene ETA achieves a large bending angle of 270° with a fast response of 8 s and the recovery process costs 19 s. The large bending deformation is reversible and can be precisely controlled by the driving voltage. A simple robotic hand prepared by using a single graphene ETA can hold the object, which is more than ten times the weight of itself. By virtue of its large-strain, fast response, and easy-to-manufacture, we believe that the graphene ETA has tremendous potential in extensive applications involving biomimetic robotics, artificial muscles, switches, and microsensors in both macroscopic and microscopic fields.
Physico-chemical properties of instant ogbono (Irvingia gabonensis) mix powder
Bamidele, Oluwaseun P; Ojedokun, Omotayo S; Fasogbon, Beatrice M
2015-01-01
The main objective of the research is to develop a recipe of instant dry soup mix for easy preparation of ogbono soup. Instant ogbono mix powder was processed using common locally ingredients. Dika kernel powder, dried ugwu leaf, crayfish, stock fish, and a mixture of locust bean, onion, seasoning and Cameroon powder were formulated at different ratios to find the best acceptable ogbono mix powder. The samples were subjected to proximate, functional, vitamin, mineral, and sensory analyses. The formulated sample D with the highest ratio of crayfish and stock fish had the highest value of protein and carbohydrate (24.13 and 35.61%, respectively). The control sample (100% dika kernel powder) was low in moisture content (6.20%) but high in crude fat, other samples followed in this order (control > A > B > C > D) for crude fat. Ash, crude fiber, and carbohydrate showed a significant difference (P < 0.05) in all the samples. The functional properties of the sample showed a significant difference (P < 0.05) in all the samples with the control having the highest value for the water absorption, swelling capacity, and bulk density which may be due to the high crude fiber and low moisture content recorded for the control sample in the proximate analysis. The mineral content of all the samples were higher than the control with phosphorous having the highest value and iron the least value. Vitamin C was the main dominating vitamin in the sample followed by vitamin B2, vitamin A, and vitamin B3. The sensory evaluation revealed that 100% dika kernel powder gave a good attribute of the soup but with less nutritional composition, while some formulated samples showed a similar attribute with higher nutritional value. Sample A with the highest overall acceptability had the best attribute of ogbono soup. Instant ogbono mix powder has higher nutritional value and easy to cook. PMID:26288723
Stability of Metronidazole Suspensions.
Donnelly, Ronald F; Ying, James
2015-01-01
Metronidazole is an antiprotozoal agent used in the treatment of bacterial and protozoal anaerobic infections. The objectives of this study were to develop concentrated metronidazole suspensions that are inexpensive and easy to prepare and determine the stability of these suspensions after storage in amber polyvinyl chloride bottles at room temperature (23°C) and under refrigeration (5°C). Metronidazole suspensions (50 mg/mL) were prepared from powder using Ora-Blend or simple syrup as the vehicles. Samples were collected in triplicate from each container on days 0, 7, 14, 28, 56, and 93. Samples were assayed using a high-performance liquid chromatography method that had been validated as stability indicating. Color, change in physical appearance, and pH were also monitored at each time interval. There was no apparent change in color or physical appearance. The pH values changed by less than 0.20 units over the 93 days. The stability of metronidazole suspensions compounded from United States Pharmacopeia powder using Ora-Blend or simple syrup and packaged in amber polyvinyl chloride bottles was determined to be 93 days when stored at either room temperature or under refrigeration.
Rotary target method to prepare thin films of CdS/SiO 2 by pulsed laser deposition
NASA Astrophysics Data System (ADS)
Wang, H.; Zhu, Y.; Ong, P. P.
2000-12-01
Thin films of CdS-doped SiO 2 glass were prepared by using the conventional pulsed laser deposition (PLD) technique. The laser target consisted of a specially constructed rotary wheel which provided easy control of the exposure-area ratio to expose alternately the two materials to the laser beam. The physical target assembly avoided the potential complications inherent in chemically mixed targets such as in the sol-gel method. Time-of-flight (TOF) spectra confirmed the existence of the SiO 2 and CdS components in the thin-film samples so produced. X-ray diffraction (XRD) and atomic force microscopy(AFM) results showed the different sizes and structures of the as-deposited and annealed films. The wurtzite phase of CdS was found in the 600 oC-annealed sample, while the as-deposited film showed a cubic-hexagonal mixed structure. In the corresponding PL (photoluminescence) spectra, a red shift of the CdS band edge emission was found, which may be a result of the interaction between the CdS nanocrystallite and SiO 2 at their interface.
Tarasov, Andrii; Rauhut, Doris; Jung, Rainer
2017-12-01
Analytical methods of haloanisoles and halophenols quantification in cork matrix are summarized in the current review. Sample-preparation and sample-treatment techniques have been compared and discussed from the perspective of their efficiency, time- and extractant-optimization, easiness of performance. Primary interest of these analyses usually addresses to 2,4,6-trichloroanisole (TCA), which is a major wine contaminant among haloanisoles. Two concepts of TCA determination are described in the review: releasable TCA and total TCA analyses. Chromatographic, bioanalytical and sensorial methods were compared according to their application in the cork industry and in scientific investigations. Finally, it was shown that modern analytical techniques are able to provide required sensitivity, selectivity and repeatability for haloanisoles and halophenols determination. Copyright © 2017 Elsevier B.V. All rights reserved.
Jankowski, Stéphane; Currie-Fraser, Erica; Xu, Licen; Coffa, Jordy
2008-01-01
Annotated DNA samples that had been previously analyzed were tested using multiplex ligation-dependent probe amplification (MLPA) assays containing probes targeting BRCA1, BRCA2, and MMR (MLH1/MSH2 genes) and the 9p21 chromosomal region. MLPA polymerase chain reaction products were separated on a capillary electrophoresis platform, and the data were analyzed using GeneMapper v4.0 software (Applied Biosystems, Foster City, CA). After signal normalization, loci regions that had undergone deletions or duplications were identified using the GeneMapper Report Manager and verified using the DyeScale functionality. The results highlight an easy-to-use, optimal sample preparation and analysis workflow that can be used for both small- and large-scale studies. PMID:19137113
A supporting role of Chinese National Immortalized Cell Bank in life science research.
Xu, Chong-feng; Duan, Zi-yuan
2017-01-20
A biorepository of human samples is essential to support the research of life science. Lymphoblastoid B cell line (LCL), which is easy to be prepared and can reproduce indefinitely, is a convenient form of sample preservation. LCLs are established from human B cells transformed by Epstein-Barr virus (EBV). Chinese National Immortalized Cell Bank has preserved human LCLs from different ethnic groups in China. As there are many studies on the nature of LCLs and public available resources with genome-wide data for LCLs, they have been widely applied in genetics, immunology, pharmacogenetics/genomics, regenerative medicine, cancer pathogenesis and immunotherapy, screening and generation of fully human neutralizing monoclonal antibodies and study on EBV pathogenesis. Here, we review the characteristics of LCLs and their contributions to scientific research, and introduce preserved samples in Chinese National Immortalized Cell Bank to the scientific community. We hope this bank can support more areas in the scientific research.
Sägmüller, B; Schwarze, B; Brehm, G; Schneider, S
2001-11-01
A method based on surface-enhanced Raman scattering (SERS) spectroscopy was developed to meet the need for the reliable and rapid identification of illicit drugs such as the 'designer drug' XTC, preferably to increase the security of legal certificates. A matrix stabilized silver halide dispersion on a microtiter plate is used as the SERS-active substrate, providing an easy to use system for sample preparation and probing by means of a Raman microscope. The potential of the method is demonstrated by applying it to the identification of the psychoactive ingredients of drug containing tablets which were confiscated by the local police at techno-music events. The samples of interest were 26 different brands of XTC tablets and several pieces of evidence (powders) containing amphetamine. For reference, we show SERS and Raman spectra of pristine amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyethamphetamine.
Drechsel, Lisa; Schulz, Martin; von Stetten, Felix; Moldovan, Carmen; Zengerle, Roland; Paust, Nils
2015-02-07
Lab-on-a-chip devices hold promise for automation of complex workflows from sample to answer with minimal consumption of reagents in portable devices. However, complex, inhomogeneous samples as they occur in environmental or food analysis may block microchannels and thus often cause malfunction of the system. Here we present the novel AutoDip platform which is based on the movement of a solid phase through the reagents and sample instead of transporting a sequence of reagents through a fixed solid phase. A ball-pen mechanism operated by an external actuator automates unit operations such as incubation and washing by consecutively dipping the solid phase into the corresponding liquids. The platform is applied to electrochemical detection of organophosphorus pesticides in real food samples using an acetylcholinesterase (AChE) biosensor. Minimal sample preparation and an integrated reagent pre-storage module hold promise for easy handling of the assay. Detection of the pesticide chlorpyrifos-oxon (CPO) spiked into apple samples at concentrations of 10(-7) M has been demonstrated. This concentration is below the maximum residue level for chlorpyrifos in apples defined by the European Commission.
NASA Astrophysics Data System (ADS)
Shetty, Krushitha; Lokesh, S. V.; Rangappa, Dinesh; Nagaswarupa, H. P.; Nagabhushana, H.; Anantharaju, K. S.; Prashantha, S. C.; Vidya, Y. S.; Sharma, S. C.
2017-02-01
Here, a green route has been reported to convert Graphene Oxide (GO) to reduced graphene oxide (RGO) using clove extract. A modest and eco-accommodating sol-gel strategy has been employed to prepare MgFe2O4 nanoparticles, MgFe2O4-RGO nanocomposite samples. The samples were analyzed by Powder X-ray diffraction (PXRD), Fourier Transform Infrared Spectroscopy (FTIR), UV-Visible Spectroscopy, Scanning Electron Microcopy (SEM), Transmission Electron Microscopy (TEM), Photoluminescence (PL) and Electrochemical Impedance Spectroscopy (EIS). PXRD result revealed that the prepared samples were cubic spinel in nature. SEM results uncovered flake like surface morphology of the prepared nanomaterial. Better PL emission signature was observed when excited at 329 nm. PL studies demonstrated that the present samples were potential for the fabrication of white component of white light emitting diodes (WLEDs). Further, MgFe2O4-RGO nanocomposite showed enhanced photocatalytic movement (PCM) and photostability under Sunlight in the decomposition of Malachite Green (MG) compared to MgFe2O4. This can be attributed to the interaction of MgFe2O4 surface with RGO sheets which results in PL quenching, demonstrates that the recombination of photo-induced electrons and holes in MgFe2O4-RGO nanocomposite is more effectively inhibited. A possible mechanism for the enhanced properties of MgFe2O4-RGO nanocomposite was discussed. Moreover, MgFe2O4-RGO photocatalyst also showed easy magnetic separation with high reusability. These results unveil that the synthesized sample can be used in display applications and also as a potential photocatalyst.
Development of a mercury detection kit based on melamine-functionalized gold nanoparticles.
Liu, Guoyan; Ren, Huipeng; Guan, Yuyu; Dai, Ronghua; Chai, Chunyan
2015-01-01
A fast and simple mercury detection kit was developed based on melamine-functionalized gold nanoparticles (GNPs). The detection kit contained reagent 1 (GNPs), reagent 2 (melanine), a reaction cuvette with four separated cells, a colorimetric card and a plastic pipette. The GNPs were prepared by a citrate reduction of HAuCl4. A proper amount of melamine was applied to functionalize the GNPs. The complex reaction took place in the present of Hg(2+) in the test samples, leading to the combination of Hg(2+) with the C=N group of melamine located on the surface of the GNPs. This reaction resulted in damage to the stability of colloid gold, and the aggregation of GNPs occurred. Different color changes (from claret-red to lilac, purple and plum) were displayed with different concentrations of Hg(2+) in the test samples. It was very easy and convenient to determine the amount of mercury ion by the naked eye. The advantages of this methodology are listed as follows: a short detecting time (within 10 min), a high specificity (no significant interference was indicated upon adding a certain amount of Cu(2+), Pb(2+), Zn(2+), Mg(2+), Cd(2+) and Fe(2+)), high sensitivity with a detection limit of 0.01 mg L(-1) , easy operation and practical on-site use.
Romão, Wanderson; Sabino, Bruno D; Bueno, Maria Izabel M S; Vaz, Boniek G; Júnior, Amadeu C; Maldaner, Adriano O; de Castro, Eustáquio V R; Lordeiro, Rogério A; Nascentes, Clésia C; Eberlin, Marcos N; Augusti, Rodinei
2012-09-01
Normally, the identification of the LSD drug is performed by forensic laboratories, using the Ehrlich spot test. However, this is a nonspecific analysis. Additionally, the Brazilian Federal Police has identified the presence of a new compound in seized blotters: 9,10-dihydro-LSD, an uncontrolled substance. In this work, easy ambient sonic-spray ionization mass spectrometry in the positive ion mode, EASI(+)-MS, was used to characterize LSD and 9,10-dihydro-LSD compositions directly from the surface of blotters. The presence of LSD in the seized blotter samples were also confirmed via high-performance liquid chromatography with ultraviolet detector. In a set of 41 blotters analyzed by EASI(+)-MS, 28 showed positive results for LSD, seven for 9,10-dihydro-LSD, and another six samples showed negative results for both LSD and 9,10-dihydro-LSD. The combination of thin layer chromatography with EASI-MS also demonstrated to be a relatively simple and powerful screening tool for forensic analysis of street drugs. © 2012 American Academy of Forensic Sciences.
Stop Programming Robots: How to Prepare Every Student for Success in Any Career
ERIC Educational Resources Information Center
Chester, Eric
2012-01-01
While technology has made communicating "easy," it has done so at the cost of communication that is "meaningful." And for information to be internalized to the point where it is remembered, used and valued, it must be meaningful. In other words, technology makes it easy to disseminate massive amounts of information to the masses, but teaching a…
NASA Astrophysics Data System (ADS)
Rudman, Reuben
1999-06-01
Wiley-VCH: New York, 1998. xxiv + 333 pp. ISBN 0-471-19458-1. $79.95. I would have subtitled this book "All You Ever Wanted To Know about ...Sample Preparation". Although its principal thrust is geared towards the analytical chemist in an X-ray diffraction (XRD) or X-ray fluorescence (XRF) service laboratory, this text will be of use primarily as a reference source in all milieus dealing with undergraduate research projects and advanced laboratory courses in physical and analytical chemistry. It contains dozens of suggestions for preparing randomly oriented small samples of nearly anything. For example, rocks and minerals, soft organics and hard ceramics, radioactive and liquid materials, metals and oils are all treated. As the availability of XRD and XRF equipment has increased, so has the use of these techniques in the teaching schedule. Many undergraduate laboratory and research projects utilizing these methods have been described in the literature and are found in laboratory textbooks. Very often, especially with the increasingly common use of automated computer-controlled instrumentation, sample preparation has become the key experimental technique required for successful data collection. However, it is not always easy to prepare the statistically random distribution of small particles (crystallites) that is required by these methods. A multitude of techniques have been developed over the past 70 years, but many of them have been handed down by word of mouth or are scattered throughout the literature. This book represents an attempt to systematically describe the theory and practice of sample preparation. This excellent guide to the intricacies of sample preparation begins with a description of statistical sampling methods and the principles of grinding techniques. After a discussion of XRF specimen preparation, which includes pressing pellets, fusion methods, crucible selection and handling very small samples, detailed descriptions for handling rocks, minerals, cements, metals, oils, and vegetation [sic] are given. The preparation of XRD samples is described for various diffraction equipment geometries (utilizing both counter and film detectors), including specific information regarding the use of flat specimens and slurries, the use of internal standards, and the effects of crystallite size on the diffraction pattern. Methods for handling ceramics, clays, zeolites, air-sensitive samples, thin films, and plastics are described, along with the special handling requirements for materials to be studied by high-pressure, high-temperature, or low-temperature techniques. One whole chapter is devoted to the equipment used in specimen preparation, including grinders, pulverizers, presses, specimen holders, repair of platinumware, and sources of all types of special equipment. Did you ever want to know where to get a Plattner steel mortar or a micronizing mill or soft-glass capillary tubes with 0.01-mm wall thickness? It's all here in this monograph. The book ends with a good glossary of terms, a general bibliography in addition to the extensive list of references following each of its 9 chapters, and an index. It will be of help in many areas of spectroscopy and analytical chemistry, as well as in XRD and XRF analyses.
Compositional dependence of magnetic anisotropy in chemically synthesized Co3- x Fe x O4 (0 ≤ x ≤ 2)
NASA Astrophysics Data System (ADS)
Hayashi, Kensuke; Yamada, Keisuke; Shima, Mutsuhiro
2018-01-01
Magnetic anisotropy of Co3- x Fe x O4 (CFO, 0 ≤ x ≤ 2) thin-film and powder samples prepared by a sol-gel method has been investigated as a function of Fe composition x. Structural analyses by X-ray diffraction show that CFO powder samples exhibit diffraction peaks associated with the spinel structure when x < 2, while CFO thin-film samples with thickness of 130-510 nm yield the peaks when 0 ≤ x ≤ 2. CFO thin-film samples are highly (111)-oriented with the Lotgering factor greater than 0.9 when 0.6 ≤ x ≤ 1.3. The magnetic anisotropy constant K 1 of CFO powder samples estimated from their room-temperature hysteresis loops yields a minimum when x = 0.9. Relatively large in-plane magnetic anisotropy (K eff = 5.7 × 105 erg/cm3) is observed for the CFO thin-film sample when x = 1.3. With increasing x, the magnetic easy axis of the spinel CFO changes from 〈111〉 to 〈100〉 when x = 0.9.
Shimizu, Shuji; Ohtsuka, Takao; Takahata, Shunichi; Nagai, Eishi; Nakashima, Naoki; Tanaka, Masao
2016-01-01
Live demonstration of endoscopy is one of the most attractive and useful methods for education and is often organized locally in hospitals. However, problems have been apparent in terms of cost, preparation, and potential risks to patients. Our aim was to evaluate a new approach to live endoscopy whereby remote hospitals are connected by the Internet for live endoscopic demonstrations. Live endoscopy was transmitted to the Congress of the Japan Gastroenterological Endoscopic Society by 13 domestic and international hospitals. Patients with upper and lower gastrointestinal diseases and with pancreatobiliary disorders were the subjects of a live demonstration. Questionnaires were distributed to the audience and were sent to the demonstrators. Questions concerned the quality of transmitted images and sound, cost, preparations, programs, preference of style, and adverse events. Of the audience, 91.2% (249/273) answered favorably regarding the transmitted image quality and 93.8% (259/276) regarding the sound quality. All demonstrators answered favorably regarding image quality and 93% (13/14) regarding sound quality. Preparations were completed without any outsourcing at 11 sites (79%) and were evaluated as 'very easy' or 'easy' at all but one site (92.3%). Preparation cost was judged as 'very cheap' or 'cheap' at 12 sites (86%). Live endoscopy connecting multiple international centers was satisfactory in image and sound quality for both audience and demonstrators, with easy and inexpensive preparation. The remote transmission of live endoscopy from demonstrators' own hospitals was preferred to the conventional style of locally organized live endoscopy. © 2015 The Authors Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.
Direct Blood Dry LAMP: A Rapid, Stable, and Easy Diagnostic Tool for Human African Trypanosomiasis
Hayashida, Kyoko; Kajino, Kiichi; Hachaambwa, Lottie; Namangala, Boniface; Sugimoto, Chihiro
2015-01-01
Loop-mediated isothermal amplification (LAMP) is a rapid and sensitive tool used for the diagnosis of a variety of infectious diseases. One of the advantages of this method over the polymerase chain reaction is that DNA amplification occurs at a constant temperature, usually between 60–65°C; therefore, expensive devices are unnecessary for this step. However, LAMP still requires complicated sample preparation steps and a well-equipped laboratory to produce reliable and reproducible results, which limits its use in resource-poor laboratories in most developing countries. In this study, we made several substantial modifications to the technique to carry out on-site diagnosis of Human African Trypanosomiasis (HAT) in remote areas using LAMP. The first essential improvement was that LAMP reagents were dried and stabilized in a single tube by incorporating trehalose as a cryoprotectant to prolong shelf life at ambient temperature. The second technical improvement was achieved by simplifying the sample preparation step so that DNA or RNA could be amplified directly from detergent-lysed blood samples. With these modifications, diagnosis of HAT in local clinics or villages in endemic areas becomes a reality, which could greatly impact on the application of diagnosis not only for HAT but also for other tropical diseases. PMID:25769046
Yang, Feiyu; Zou, Yun; Ni, Chunfang; Wang, Rong; Wu, Min; Liang, Chen; Zhang, Jiabin; Yuan, Xiaoliang; Liu, Wenbin
2017-11-01
An easy-to-handle magnetic dispersive solid-phase extraction procedure was developed for preconcentration and extraction of cocaine and cocaine metabolites in human urine. Divinyl benzene and vinyl pyrrolidone functionalized silanized Fe 3 O 4 nanoparticles were synthesized and used as adsorbents in this procedure. Scanning electron microscopy, vibrating sample magnetometry, and infrared spectroscopy were employed to characterize the modified adsorbents. A high-performance liquid chromatography with mass spectrometry method for determination of cocaine and its metabolites in human urine sample has been developed with pretreatment of the samples by magnetic dispersive solid-phase extraction. The obtained results demonstrated the higher extraction capacity of the prepared nanoparticles with recoveries between 75.1 to 105.7% and correlation coefficients higher than 0.9971. The limits of detection for the cocaine and cocaine metabolites were 0.09-1.10 ng/mL. The proposed magnetic dispersive solid-phase extraction method provided a rapid, environmentally friendly and magnetic stuff recyclable approach and it was confirmed that the prepared adsorbents material was a kind of highly effective extraction materials for the trace cocaine and cocaine metabolites analyses in human urine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Synthesis and property of spinel porous ZnMn2O4 microspheres
NASA Astrophysics Data System (ADS)
Guo, N.; Wei, X. Q.; Deng, X. L.; Xu, X. J.
2015-11-01
Mesoporous ternary zinc manganese oxides on the Ti sheet substrate are prepared by easy and fast hydrothermal method for the first time. The obtained ZnMn2O4 materials with homogenously distributed pores have been characterized by XRD, SEM and Raman spectra, which show the good crystal phase and particles for improving supercapacitive performance. XRD and SEM images show that the as-prepared samples have good crystallinity, and ZnMn2O4 microsphere has an average diameter of 10 μm. In addition, ZnMn2O4 are also characterized in 2 M KOH solution using three-electrode system. In the work, we study that different substrates (Ti, carbon and nickel foam) have an important effect on the electrochemical performance of the samples. The research of cyclic voltammogram (CV) indicates that the obtained specific capacitance (155 F g-1) values on nickel foam substrate for the ZnMn2O4 microspheres are higher than the values reported for some inexpensive oxides. However, the specific capacitance of all ZnMn2O4 samples has almost no change at two different scan rates which shows good long-term cycling stability. The electrochemical impedance spectroscopy with a small resistance reveals that the as-synthesized samples have good frequency response characteristics. These results indicate that the unique ZnMn2O4 electrode would be a promising electrode for high-performance supercapacitor applications.
Lécuyer, Christophe; Fourel, François; Martineau, François; Amiot, Romain; Bernard, Aurélien; Daux, Valérie; Escarguel, Gilles; Morrison, John
2007-01-01
A high-precision, and rapid on-line method for oxygen isotope analysis of silver phosphate is presented. The technique uses high-temperature elemental analyzer (EA)-pyrolysis interfaced in continuous flow (CF) mode to an isotopic ratio mass spectrometer (IRMS). Calibration curves were generated by synthesizing silver phosphate with a 13 per thousand spread in delta(18)O values. Calibration materials were obtained by reacting dissolved potassium dihydrogen phosphate (KH(2)PO(4)) with water samples of various oxygen isotope compositions at 373 K. Validity of the method was tested by comparing the on-line results with those obtained by classical off-line sample preparation and dual inlet isotope measurement. In addition, silver phosphate precipitates were prepared from a collection of biogenic apatites with known delta(18)O values ranging from 12.8 to 29.9 per thousand (V-SMOW). Reproducibility of +/- 0.2 per thousand was obtained by the EA-Py-CF-IRMS method for sample sizes in the range 400-500 microg. Both natural and synthetic samples are remarkably well correlated with conventional (18)O/(16)O determinations. Silver phosphate is a very stable material and easy to degas and, thus, could be considered as a good candidate to become a reference material for the determination of (18)O/(16)O ratios of phosphate by high-temperature pyrolysis. Copyright 2006 John Wiley & Sons, Ltd.
Farzbod, Ali; Moon, Hyejin
2018-05-30
This paper presents the demonstration of on-chip fabrication of a potassium-selective sensor array enabled by electrowetting on dielectric digital microfluidics for the first time. This demonstration proves the concept that electrochemical sensors can be seamlessly integrated with sample preparation units in a digital microfluidic platform. More significantly, the successful on-chip fabrication of a sensor array indicates that sensors become reconfigurable and have longer lifetime in a digital microfluidic platform. The on-chip fabrication of ion-selective electrodes includes electroplating Ag followed by forming AgCl layer by chemical oxidation and depositing a thin layer of desired polymer-based ion selective membrane on one of the sensor electrodes. In this study, potassium ionophores work as potassium ion channels and make the membrane selective to potassium ions. This selectiveness results in the voltage difference across the membrane layer, which is correlated with potassium ion concentration. The calibration curve of the fabricated potassium-selective electrode demonstrates the slope of 58 mV/dec for potassium concentration in KCl sample solutions and shows good agreement with the ideal Nernstian response. The proposed sensor platform is an outstanding candidate for a portable home-use for continuous monitoring of ions thanks to its advantages such as easy automation of sample preparation and detection processes, elongated sensor lifetime, minimal membrane and sample consumption, and user-definable/reconfigurable sensor array. Copyright © 2018 Elsevier B.V. All rights reserved.
Flinders, Bryn; Cuypers, Eva; Zeijlemaker, Hans; Tytgat, Jan; Heeren, Ron M A
2015-10-01
Matrix-assisted laser desorption/ionization-mass spectrometry imaging (MALDI-MSI) for the analysis of intact hair is a powerful tool for the detection of drugs of abuse in toxicology and forensic applications. Here we present a quick, easy, and reproducible method of preparing longitudinal sections of single hairs. This method improves the accessibility of chemicals embedded in the hair matrix for molecular imaging with mass spectrometry. The images obtained from a single, sectioned hair sample show molecular distributions in the exposed medulla, cortex, and a portion of the cuticle observed as a narrow layer surrounding the cortex. Using MALDI-MS/MS imaging, the distribution of cocaine was observed throughout five longitudinally sectioned drug-user hair samples. The images showed the distribution of the product ion at m/z 182, derived from the precursor ion of cocaine at m/z 304. MetA-SIMS images of longitudinally sectioned hair samples showed a more detailed distribution of cocaine at m/z 304, benzoylecgonine the major metabolite of cocaine at m/z 290 and other drugs such as methadone which was observed at m/z 310. Chronological information of drug intake can be obtained more sensitively. The chronological detail is in hours rather than months, which is of great interest in clinical as well as forensic applications. Copyright © 2015 John Wiley & Sons, Ltd.
Choosing High School Courses with Purpose
ERIC Educational Resources Information Center
Ayotte, Steve; Sevier, Sharon
2010-01-01
In choosing high school courses, students often seem to focus on everything except preparation for an intended major or career. They consider graduation requirements, weighted classes, easy classes...but rarely are these types of choices preparing students for postsecondary education. This article describes the "Career Companion Guide"…
Formulation, Preparation, and Characterization of Polyurethane Foams
ERIC Educational Resources Information Center
Pinto, Moises L.
2010-01-01
Preparation of laboratory-scale polyurethane foams is described with formulations that are easy to implement in experiments for undergraduate students. Particular attention is given to formulation aspects that are based on the main chemical reactions occurring in polyurethane production. This allows students to develop alternative formulations to…
Preparation of Low-Input and Ligation-Free ChIP-seq Libraries Using Template-Switching Technology.
Bolduc, Nathalie; Lehman, Alisa P; Farmer, Andrew
2016-10-10
Chromatin immunoprecipitation (ChIP) followed by high-throughput sequencing (ChIP-seq) has become the gold standard for mapping of transcription factors and histone modifications throughout the genome. However, for ChIP experiments involving few cells or targeting low-abundance transcription factors, the small amount of DNA recovered makes ligation of adapters very challenging. In this unit, we describe a ChIP-seq workflow that can be applied to small cell numbers, including a robust single-tube and ligation-free method for preparation of sequencing libraries from sub-nanogram amounts of ChIP DNA. An example ChIP protocol is first presented, resulting in selective enrichment of DNA-binding proteins and cross-linked DNA fragments immobilized on beads via an antibody bridge. This is followed by a protocol for fast and easy cross-linking reversal and DNA recovery. Finally, we describe a fast, ligation-free library preparation protocol, featuring DNA SMART technology, resulting in samples ready for Illumina sequencing. © 2016 by John Wiley & Sons, Inc. Copyright © 2016 John Wiley & Sons, Inc.
Song, Chihong; Lee, Ju Huck; Jun, Sangmi; Chung, Jeong Min; Hyun, Jaekyung; Jung, Hyun Suk
2016-05-01
The preparation of biological specimens using cryofixation techniques ensures excellent visibility of intracellular structures and preserves the antigenic sites of subcellular molecules. Hence, cryofixation is an effective method of preparing samples for analyses using antibodies conjugated to gold nanoparticles that are designed to detect the localization of specific target molecules within cells. However, cryofixation cannot be utilized easily because it requires expensive equipment and skilled technologists, resulting in a high level of expense for researchers. Here, we describe a simple technical approach to cryofixation that uses metal contact quick freezing followed by a modified freeze substitution technique and immuno-gold labeling electron microscopy. Micrograph images of cells prepared using this modified cryofixation method demonstrated its superiority over chemical fixation for high contrast visualization of the morphologies of cellular components and preservation of antigenicity for immuno-gold labeling. This report provides valuable technical information related to the advancement of metal contact quick freezing techniques, which can be used to visualize biomedical events of interest in an easy, simple, and rapid manner.
NASA Astrophysics Data System (ADS)
Kitazaki, Tomoya; Mori, Keita; Yamamoto, Naoyuki; Wang, Congtao; Kawashima, Natsumi; Ishimaru, Ichiro
2017-07-01
We proposed the extremely compact beans-size snap-shot mid-infrared spectroscopy that will be able to be built in smartphones. And also the easy preparation method of thin-film samples generated by ultrasonic standing wave is proposed. Mid-infrared spectroscopy is able to identify material components and estimate component concentrations quantitatively from absorption spectra. But conventional spectral instruments were very large-size and too expensive to incorporate into daily life. And preparations of thin-film sample were very troublesome task. Because water absorption in mid-infrared lights is very strong, moisture-containing-sample thickness should be less than 100[μm]. Thus, midinfrared spectroscopy has been utilized only by analytical experts in their laboratories. Because ultrasonic standing wave is compressional wave, we can generate periodical refractive-index distributions inside of samples. A high refractiveindex plane is correspond to a reflection boundary. When we use a several MHz ultrasonic transducer, the distance between sample surface and generated first node become to be several ten μm. Thus, the double path of this distance is correspond to sample thickness. By combining these two proposed methods, as for liquid samples, urinary albumin and glucose concentrations will be able to be measured inside of toilet. And as for solid samples, by attaching these apparatus to earlobes, the enhancement of reflection lights from near skin surface will create a new path to realize the non-invasive blood glucose sensor. Using the small ultrasonic-transducer whose diameter was 10[mm] and applied voltage 8[V], we detected the internal reflection lights from colored water as liquid sample and acrylic board as solid sample.
Preliminary Development of an Object-Oriented Optimization Tool
NASA Technical Reports Server (NTRS)
Pak, Chan-gi
2011-01-01
The National Aeronautics and Space Administration Dryden Flight Research Center has developed a FORTRAN-based object-oriented optimization (O3) tool that leverages existing tools and practices and allows easy integration and adoption of new state-of-the-art software. The object-oriented framework can integrate the analysis codes for multiple disciplines, as opposed to relying on one code to perform analysis for all disciplines. Optimization can thus take place within each discipline module, or in a loop between the central executive module and the discipline modules, or both. Six sample optimization problems are presented. The first four sample problems are based on simple mathematical equations; the fifth and sixth problems consider a three-bar truss, which is a classical example in structural synthesis. Instructions for preparing input data for the O3 tool are presented.
Marquardt, Christian; Paulheim, Alexander; Rohbohm, Nils; Merkel, Rudolf; Sokolowski, Moritz
2017-08-01
We modified an epi-illumination light microscope and mounted it on an ultra high vacuum chamber for investigating samples used in a surface science experiment. For easy access and bake out, all optical components are placed outside the vacuum and the sample is imaged through a glass window. The microscope can be operated in reflection brightfield or epifluorescence mode to image the sample surface or fluorescent dye molecules adsorbed on it. The homemade sample mounting was made compatible for the use under the microscope; sample temperatures as low as 6 K can be achieved. The performance of the microscope is demonstrated on two model samples: Brightfield-images of a well-prepared Ag(100) surface show a macroscopic corrugation of the surface, although low energy electron diffraction data indicate a highly ordered crystalline surface. The surface shows macroscopic protrusions with flat regions, about 20-200 μm in diameter, in between. Fluorescence images of diluted 3,4,9,10-perylene tetracarboxylicacid dianhydride (PTCDA) molecules adsorbed on an ultrathin epitaxial KCl film on the Ag(100) surface show a shading effect at surface protrusions due to an inclined angle of incidence of the PTCDA beam during deposition. For some preparations, the distribution of the fluorescence intensity is inhomogeneous and shows a dense network of bright patches about 5 μm in diameter related to the macroscopic corrugation of the surface. We propose that such a light microscope can aid many surface science experiments, especially those dealing with epitaxial growth or fluorescent materials.
Li, Dan; Zou, Juan; Cai, Pei-Shan; Xiong, Chao-Mei; Ruan, Jin-Lan
2016-06-05
In this study, conventional thin-film microextraction (TFME) was endowed with magnetic by introducing superparamagnetic SiO2@Fe3O4 nanoparticles in thin-films. Novel magnetic octadecylsilane (ODS)-polyacrylonitrile (PAN) thin-films were prepared by spraying, and used for the microextraction of quetiapine and clozapine in plasma and urine samples, followed by the detection of HPLC-UV. The influencing factors on the extraction efficiency of magnetic ODS-PAN TFME, including pH, extraction time, desorption solvent, desorption time, and ion strength were investigated systematically. Under the optimal conditions, both analytes showed good linearity over ranges of 0.070-9.000μgmL(-1) and 0.012-9.000μgmL(-1) in plasma and urine samples, respectively, with correlation coefficients (R(2)) above 0.9990. Limits of detection (LODs) for quetiapine in plasma and urine samples were 0.013 and 0.003μgmL(-1), respectively. LODs for clozapine in plasma and urine samples were 0.015 and 0.003μgmL(-1), respectively. The relative standard deviations (RSDs) for quetiapine and clozapine were less than 9.23%. After the validation, the protocol was successfully applied for the determination of quetiapine and clozapine in patients' plasma and urine samples with satisfactory recoveries between 99-110%. The proposed magnetic ODS-PAN TFME was very simple, fast and easy to handle. It showed high potential as a powerful pretreatment technology for routine therapeutic drug monitoring (TDM) in plasma and urine samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Rahman, Siti Khadijah Ab.; Yusof, Nor Azah; Abdullah, Abdul Halim; Idris, Azni; Al-lohedan, Hamad A.
2018-01-01
In the present study, ion imprinted polymer monoliths (IIPMs) were developed to overcome the limitations of ion imprinted polymer particles (IIPPs) used for the removal of Hg(II) ions from waste water samples. The adsorbents preparation, characterization and Hg(II) removal were very well reported. The IIPMs on porogen optimization was prepared using the molding technique with Hg(II) as a template ion, [2-(methacryloyloxy)ethyl]trimethylammonium cysteine (MAETC) as ligand, methacrylic acid (MAA) as functional monomer, ethylene glycol dimethacrylamide (EGDMA) as cross-linker, benzoyl peroxide as an initiator and methanol and acetonitrile as porogen in the polypropylene tube (drinking straw) as mold. The IIPMs prepared with higher volumes of porogen were indicated to have a good adsorption rate for the Hg(II) removal along with good water permeability and larger porosity as compared to a lower volume of porogen. The IIPMs prepared using the binary porogen were able to improve the porosity and surface area of the monolithic polymers as compared to the single porogen added IIPMs. Finally, we indicate from our analysis that the IIPM having the efficient capacity for the Hg(II) ions is easy to prepare, and has higher water permeability along with high porosity and high adsorption capacity and all these factors making it one of the suitable adsorbent for the successful removal of Hg(II) ions. PMID:29649325
ERIC Educational Resources Information Center
Parlakkilic, Alattin
2015-01-01
Generally it is not easy for an instructor to prepare and deliver electronic courses via e-learning. Therefore it is necessary to work and develop an easy system. In this context module technology was used to for provide modularity in conducting educational development of e-learning course. Then, rapid e-learning was used for more quick and easy…
Considerations Regarding the Optical Properties of the Composite Resin Restorative Materials
Manolea, H.; Râcă, R.; Coleş, Evantia; Preotu, Gabriela; Mărăşescu, P.
2011-01-01
The purpose of this study has been to investigate the effects of certain substances frequently used in alimentation on the color stability of the composite resin restorative materials. The research hypothesis was that color stability of the composite resin is affected by the type of composite material used and by the polishing procedure. 14 samples of 5X15X2mm have been prepared from seven universal light curing restorative composite resins. The materials have manipulated and cured using LA 500 Blue Light lamp. A first color determination was done before the introduction of the samples in the dyeing agent with the help of an Easy Shade device. The samples have been splited into two lots each with seven samples. The samples from the first lot have been sectioned into three equal segments. The samples from the second lot have also been sectioned into three equal segments, and in addition to the previous group, their exterior surfaces were processed with a diamond burr. For each type of composite we have introduced a sample in one of the three chosen dyes: red alimentary colorant, coffee and red wine. The color of the samples has been determined again using the Vita Easy Shade device. From clinical point of view the results of this study shows that there are three important factors that matter when we talk about durable aesthetic results: the type of composite resin used for the restoration, the finishing and polishing procedures and the pacients’ alimentation habits. The composite resins with a good representation of the anorganic structure are easier to be polished, therefore they have only slight color modifications. Using plastic matrixes for shaping the exterior surface of the restoration is the best solution for obtaining a very smooth surface. The most significant color modifications have been done by the red wine. Coffee and to a smaller extent the red alimentary colorant have modified the color of the restoration material in a smaller degree. PMID:24778835
Improving a Lecture-Size Molecular Model Set by Repurposing Used Whiteboard Markers
ERIC Educational Resources Information Center
Dragojlovic, Veljko
2015-01-01
Preparation of an inexpensive model set from whiteboard markers and either HGS molecular model set or atoms made of wood is described. The model set is relatively easy to prepare and is sufficiently large to be suitable as an instructor set for use in lectures.
[Development of pseudoviral competitive internal controls for RT-PCR detection of dengue virus].
Hang, Xiao-Tong; Li, Jian-Dong; Zhang, Quan-Fu; Li, Chuan; Zhang, Shuo; Liang, Mi-Fang; Li, De-Xin
2010-02-01
Development of pseudoviral competitive internal controls for RT-PCR laboratory detection of dengue virus. The internal controls target gene were obtained by insertion of a 180 bp non-related DNA fragment into RT-PCR detection target of dengue virus between the forward and reverse PCR primer binding regions. A yellow florescence protein reporter gene was induced at downstream of internal controls target gene via internal ribosome entry site gene. HEK 293T cells were transfected with plasmid containing this whole cassette and lentiviral packaging support plasmid. Pseudoviral particle was recovered from the supernatant and analyzed quantitatively and qualitatively in simulated samples at the same tube under different experimental conditions. The established pseudoviral competitive internal controls can be used in the RT-PCR detection of different serotype dengue virus and the whole detection process can be monitored. The obtained fragment is easy to be differentiated in agarose electrophoresis. The pseudoviral competitive internal controls could be used for the quality control of the laboratory diagnosis process, simple to prepare, stable for storage, easy to be transformed into internal controls for other RNA virus.
Yoon, Sung-No; Yoo, Byoungseung
2017-06-01
Thickened infant formula (TIF) prepared with commercial xanthan gum (XG)-based food thickeners are commonly used to care for infants with swallowing difficulties or regurgitation. In this study, the rheological properties of TIF prepared with four commercial food thickeners (coded A-D) were determined as a function of thickener concentration, thickener type, and setting time because the selection of an appropriate food thickener for TIF preparation is necessary for managing dysphagia in infants. The flow and dynamic rheological properties of TIF were investigated at three different concentrations (1.0, 2.0, and 3.0% w/w) of XG-based thickener. The flow properties of TIF were described by the power law and Casson models. All TIF samples demonstrated high shear-thinning (n = 0.12-0.33) behavior at all concentrations (1.0-3.0%). Their apparent viscosity (η a,50 ), consistency index (K), yield stress (σ oc ), storage modulus (G'), and loss modulus (G″) increased with an increase in thickener concentration. In general, TIF with thickener A had much higher values for all flow parameters at each thickener concentration when compared to TIF with other thickeners (B, C, and D). However, the n values of TIF samples with thickener A were much lower, indicating that they are less slimy and have better mouthfeel than those of TIF samples with other thickeners. All TIF samples with different thickeners produced different thickening patterns over a setting time. The flow and dynamic rheological parameters demonstrated differences in the rheological behaviors between XG-based thickeners, indicating that their rheological properties are related to the concentration and type of thickener as well as the setting time. These results suggest the importance of considering not only the concentration and type of thickeners but also the time being administered after its addition to effectively treat dysphagic infants. In addition, selecting an appropriate commercial food thickener appears to be of great importance for the safe and easy swallowing of dysphagic infants.
Stability of extemporaneously prepared rufinamide oral suspensions.
Hutchinson, David J; Liou, Yayin; Best, Robert; Zhao, Fang
2010-03-01
Rufinamide is an oral antiepileptic drug indicated for adjunctive therapy in treating generalized seizures associated with Lennox-Gastaut syndrome. Currently, rufinamide is available as 200-mg and 400-mg tablets. A liquid dosage form does not exist at the present time. Lack of a suspension formulation may present an administration problem for many children and adults who are unable to swallow tablets. The availability of a liquid dosage form will provide an easy and accurate way to measure and administer the medication. To determine the stability of both sugar-containing and sugar-free rufinamide suspensions over a 90-day period. A suspension of rufinamide 40 mg/mL was prepared by grinding twelve 400-mg tablets of rufinamide tablets in a glass mortar. Sixty milliliters of Ora-Plus and 60 mL of either Ora-Sweet or Ora-Sweet SF (sugar free) were mixed and added to the powder to make a final volume of 120 mL. Three identical samples of each formulation were prepared and placed in 60-mL amber plastic bottles and were stored at room temperature. A 1-mL sample was withdrawn from each of the 6 bottles with a micropipette immediately after preparation and at 7, 14, 28, 56, and 90 days. After further dilution to an expected concentration of 0.4 mg/mL, the samples were assayed using high-performance liquid chromatography. Stability was defined as the retention of at least 90% of the initial concentration. At least 90% of the initial rufinamide concentration remained throughout the 90-day study period in both preparations. There were no detectable changes in color, odor, taste, and pH and no visible microbial growth. Extemporaneously compounded suspensions of rufinamide 40 mg/mL in a 1:1 mixture of Ora-Plus and Ora-Sweet or Ora-Sweet SF were stable for at least 90 days when stored in 59-mL amber polypropylene plastic bottles at room temperature.
Magiera, Sylwia; Kwietniowska, Ewelina
2016-11-15
In this study, an easy, simple and efficient method for the determination of naringenin enantiomers in fruit juices after salting-out-assisted liquid-liquid extraction (SALLE) and high-performance liquid chromatography (HPLC) with diode-array detection (DAD) was developed. The sample treatment is based on the use of water-miscible acetonitrile as the extractant and acetonitrile phase separation under high-salt conditions. After extraction, juice samples were incubated with hydrochloric acid in order to achieve hydrolysis of naringin to naringenin. The hydrolysis parameters were optimized by using a half-fraction factorial central composite design (CCD). After sample preparation, chromatographic separation was obtained on a Chiralcel® OJ-RH column using the mobile phase consisting of 10mM aqueous ammonium acetate:methanol:acetonitrile (50:30:20; v/v/v) with detection at 288nm. The average recovery of the analyzed compounds ranged from 85.6 to 97.1%. The proposed method was satisfactorily used for the determination of naringenin enantiomers in various fruit juices samples. Copyright © 2016 Elsevier Ltd. All rights reserved.
Haddad, Renato; Catharino, Rodrigo Ramos; Marques, Lygia Azevedo; Eberlin, Marcos Nogueira
2008-11-01
Perfume counterfeiting is an illegal worldwide practice that involves huge economic losses and potential consumer risk. EASI is a simple, easily performed and rapidly implemented desorption/ionization technique for ambient mass spectrometry (MS). Herein we demonstrate that EASI-MS allows nearly instantaneous perfume typification and counterfeit detection. Samples are simply sprayed onto a glass rod or paper surface and, after a few seconds of ambient drying, a profile of the most polar components of the perfume is acquired. These components provide unique and reproducible chemical signatures for authentic perfume samples. Counterfeiting is readily recognized since the exact set and relative proportions of the more polar chemicals, sometimes at low concentrations, are unknown or hard to reproduce by the counterfeiters and hence very distinct and variable EASI-MS profiles are observed for the counterfeit samples.
Hercegová, Andrea; Dömötörová, Milena; Kruzlicová, Dása; Matisová, Eva
2006-05-01
Four sample preparation techniques were compared for the ultratrace analysis of pesticide residues in baby food: (a) modified Schenck's method based on ACN extraction with SPE cleaning; (b) quick, easy, cheap, effective, rugged, and safe (QuEChERS) method based on ACN extraction and dispersive SPE; (c) modified QuEChERS method which utilizes column-based SPE instead of dispersive SPE; and (d) matrix solid phase dispersion (MSPD). The methods were combined with fast gas chromatographic-mass spectrometric analysis. The effectiveness of clean-up of the final extract was determined by comparison of the chromatograms obtained. Time consumption, laboriousness, demands on glassware and working place, and consumption of chemicals, especially solvents, increase in the following order QuEChERS < modified QuEChERS < MSPD < modified Schenck's method. All methods offer satisfactory analytical characteristics at the concentration levels of 5, 10, and 100 microg/kg in terms of recoveries and repeatability. Recoveries obtained for the modified QuEChERS method were lower than for the original QuEChERS. In general the best LOQs were obtained for the modified Schenck's method. Modified QuEChERS method provides 21-72% better LOQs than the original method.
Bengtsson, Oskar; Arntzen, Magnus Ø; Mathiesen, Geir; Skaugen, Morten; Eijsink, Vincent G H
2016-01-10
Analysis of the secretomes of filamentous fungi growing on insoluble lignocellulosic substrates is of major current interest because of the industrial potential of secreted fungal enzymes. Importantly, such studies can help identifying key enzymes from a large arsenal of bioinformatically detected candidates in fungal genomes. We describe a simple, plate-based method to analyze the secretome of Hypocrea jecorina growing on insoluble substrates that allows harsh sample preparation methods promoting desorption, and subsequent identification, of substrate-bound proteins, while minimizing contamination with non-secreted proteins from leaking or lysed cells. The validity of the method was demonstrated by comparative secretome analysis of wild-type H.jecorina strain QM6a growing on bagasse, birch wood, spruce wood or pure cellulose, using label-fee quantification. The proteomic data thus obtained were consistent with existing data from transcriptomics and proteomics studies and revealed clear differences in the responses to complex lignocellulosic substrates and the response to pure cellulose. This easy method is likely to be generally applicable to filamentous fungi and to other microorganisms growing on insoluble substrates. Copyright © 2015 Elsevier B.V. All rights reserved.
Accelerating effects of cellulase in the removal of denture adhesives from acrylic denture bases.
Harada-Hada, Kae; Mimura, Sumiyo; Hong, Guang; Hashida, Tatsumi; Abekura, Hitoshi; Murata, Hiroshi; Nishimura, Masahiro; Nikawa, Hiroki
2017-04-01
Studies of effective methods for the easy removal of denture adhesives from a denture base are not well represented in the literature. We previously assessed the removability of denture adhesives by immersing within denture cleaners, showing that some cleaners have a weak effect, insufficiently effective in daily use. In this study, we prepared a cellulase, as a potential component for denture adhesive removers, and we examined whether the addition of cellulase to denture cleaners is effective in the removal of cream denture adhesives. We prepared the cellulase Meicelase as one component for the liquefaction of denture adhesives. We used two denture cleaners and two cream adhesives. After the immersion of plates in sample solutions, we evaluated the area of the sample plate still covered with adhesives. Biofilm removal assay was also performed using denture cleaners containing cellulase. The addition of cellulase accelerated the removal of cream adhesives in immersion experiments to a rate faster than that of water and denture cleaners. However, it did not influence the removability of Candida albicans biofilms from acrylic resin specimens. Cellulase hastened the liquefaction of cream adhesives. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Structured Illumination Microscopy for the Investigation of Synaptic Structure and Function.
Hong, Soyon; Wilton, Daniel K; Stevens, Beth; Richardson, Douglas S
2017-01-01
The neuronal synapse is a primary building block of the nervous system to which alterations in structure or function can result in numerous pathologies. Studying its formation and elimination is the key to understanding how brains are wired during development, maintained throughout adulthood plasticity, and disrupted during disease. However, due to its diffraction-limited size, investigations of the synaptic junction at the structural level have primarily relied on labor-intensive electron microscopy or ultra-thin section array tomography. Recent advances in the field of super-resolution light microscopy now allow researchers to image synapses and associated molecules with high-spatial resolution, while taking advantage of the key characteristics of light microscopy, such as easy sample preparation and the ability to detect multiple targets with molecular specificity. One such super-resolution technique, Structured Illumination Microscopy (SIM), has emerged as an attractive method to examine synapse structure and function. SIM requires little change in standard light microscopy sample preparation steps, but results in a twofold improvement in both lateral and axial resolutions compared to widefield microscopy. The following protocol outlines a method for imaging synaptic structures at resolutions capable of resolving the intricacies of these neuronal connections.
Universal Solid-phase Reversible Sample-Prep for Concurrent Proteome and N-glycome Characterization
Zhou, Hui; Morley, Samantha; Kostel, Stephen; Freeman, Michael R.; Joshi, Vivek; Brewster, David; Lee, Richard S.
2017-01-01
SUMMARY We describe a novel Solid-phase Reversible Sample-Prep (SRS) platform, which enables rapid sample preparation for concurrent proteome and N-glycome characterization by mass spectrometry. SRS utilizes a uniquely functionalized, silica-based bead that has strong affinity toward proteins with minimal-to-no affinity for peptides and other small molecules. By leveraging the inherent size difference between, SRS permits high-capacity binding of proteins, rapid removal of small molecules (detergents, metabolites, salts, etc.), extensive manipulation including enzymatic and chemical treatments on beads-bound proteins, and easy recovery of N-glycans and peptides. The efficacy of SRS was evaluated in a wide range of biological samples including single glycoprotein, whole cell lysate, murine tissues, and human urine. To further demonstrate the SRS platform, we coupled a quantitative strategy to SRS to investigate the differences between DU145 prostate cancer cells and its DIAPH3-silenced counterpart. Our previous studies suggested that DIAPH3 silencing in DU145 prostate cancer cells induced transition to an amoeboid phenotype that correlated with tumor progression and metastasis. In this analysis we identified distinct proteomic and N-glycomic alterations between the two cells. Intriguingly, a metastasis-associated tyrosine kinase receptor ephrin-type-A receptor (EPHA2) was highly upregulated in DIAPH3-silenced cells, indicating underling connection between EPHA2 and DIAPH3. Moreover, distinct alterations in the N-glycome were identified, suggesting a cross-link between DIAPH3 and glycosyltransferase networks. Overall, SRS is an enabling universal sample preparation strategy that is not size limited and has the capability to efficiently prepare and clean peptides and N-glycans concurrently from nearly all sample types. Conceptually, SRS can be utilized for the analysis of other posttranslational modifications, and the unique surface chemistry can be further transformed for high-throughput automation. The technical simplicity, robustness, and modularity of SRS make it a highly promising technology with great potential in proteomic-based research. PMID:26791391
Cabral, Elaine C; Simas, Rosineide C; Santos, Vanessa G; Queiroga, Carmen L; da Cunha, Valnei S; de Sá, Gilberto F; Daroda, Romeu J; Eberlin, Marcos N
2012-01-01
Venturi easy ambient sonic spray ionization mass spectrometry in both its liquid (V(L) -EASI-MS) and solid sample modes (V(S) -EASI-MS) is shown to provide nearly immediate and secure typification of woods, as demonstrated for Mahogany, an endangered and most valuable type of tropical wood. This reddish wood displays unique phytochemical markers (phragmalin-type limonoids) which are rapidly detected from the wood surface by V(S) -EASI-MS or from a simple methanol extract of a tiny wood chip by V(L) -EASI-MS. Unique profiles were obtained for Mahogany (Swietenia macrophylla) whereas genuine samples of six other similar types of woods, which are commonly falsified by artificial coloring and commercialized as Mahogany, display also typical but dissimilar pythochemical profiles as compared to that of the authentic wood. Variable and atypical chemical profiles were observed for artificially colored woods. Secure chemical characterization via V(S) -EASI-MS or V(s) -EASI-MS fingerprints of Mahogany and other types of woods with similar appearance should help to control the illegal logging and trade of this and other endangered woods and their falsification, and to create certified standards. Copyright © 2012 John Wiley & Sons, Ltd.
Sung, Heungsup; Yong, Dongeun; Ki, Chang Seok; Kim, Jae Seok; Seong, Moon Woo; Lee, Hyukmin; Kim, Mi Na
2016-09-01
Real-time reverse transcription PCR (rRT-PCR) of sputum samples is commonly used to diagnose Middle East respiratory syndrome coronavirus (MERS-CoV) infection. Owing to the difficulty of extracting RNA from sputum containing mucus, sputum homogenization is desirable prior to nucleic acid isolation. We determined optimal homogenization methods for isolating viral nucleic acids from sputum. We evaluated the following three sputum-homogenization methods: proteinase K and DNase I (PK-DNase) treatment, phosphate-buffered saline (PBS) treatment, and N-acetyl-L-cysteine and sodium citrate (NALC) treatment. Sputum samples were spiked with inactivated MERS-CoV culture isolates. RNA was extracted from pretreated, spiked samples using the easyMAG system (bioMérieux, France). Extracted RNAs were then subjected to rRT-PCR for MERS-CoV diagnosis (DiaPlex Q MERS-coronavirus, SolGent, Korea). While analyzing 15 spiked sputum samples prepared in technical duplicate, false-negative results were obtained with five (16.7%) and four samples (13.3%), respectively, by using the PBS and NALC methods. The range of threshold cycle (Ct) values observed when detecting upE in sputum samples was 31.1-35.4 with the PK-DNase method, 34.7-39.0 with the PBS method, and 33.9-38.6 with the NALC method. Compared with the control, which were prepared by adding a one-tenth volume of 1:1,000 diluted viral culture to PBS solution, the ranges of Ct values obtained by the PBS and NALC methods differed significantly from the mean control Ct of 33.2 (both P<0.0001). The PK-DNase method is suitable for homogenizing sputum samples prior to RNA extraction.
Yong, Dongeun; Ki, Chang-Seok; Kim, Jae-Seok; Seong, Moon-Woo; Lee, Hyukmin
2016-01-01
Background Real-time reverse transcription PCR (rRT-PCR) of sputum samples is commonly used to diagnose Middle East respiratory syndrome coronavirus (MERS-CoV) infection. Owing to the difficulty of extracting RNA from sputum containing mucus, sputum homogenization is desirable prior to nucleic acid isolation. We determined optimal homogenization methods for isolating viral nucleic acids from sputum. Methods We evaluated the following three sputum-homogenization methods: proteinase K and DNase I (PK-DNase) treatment, phosphate-buffered saline (PBS) treatment, and N-acetyl-L-cysteine and sodium citrate (NALC) treatment. Sputum samples were spiked with inactivated MERS-CoV culture isolates. RNA was extracted from pretreated, spiked samples using the easyMAG system (bioMérieux, France). Extracted RNAs were then subjected to rRT-PCR for MERS-CoV diagnosis (DiaPlex Q MERS-coronavirus, SolGent, Korea). Results While analyzing 15 spiked sputum samples prepared in technical duplicate, false-negative results were obtained with five (16.7%) and four samples (13.3%), respectively, by using the PBS and NALC methods. The range of threshold cycle (Ct) values observed when detecting upE in sputum samples was 31.1–35.4 with the PK-DNase method, 34.7–39.0 with the PBS method, and 33.9–38.6 with the NALC method. Compared with the control, which were prepared by adding a one-tenth volume of 1:1,000 diluted viral culture to PBS solution, the ranges of Ct values obtained by the PBS and NALC methods differed significantly from the mean control Ct of 33.2 (both P<0.0001). Conclusions The PK-DNase method is suitable for homogenizing sputum samples prior to RNA extraction. PMID:27374711
Bansil, Pooja; Wittet, Scott; Lim, Jeanette L; Winkler, Jennifer L; Paul, Proma; Jeronimo, Jose
2014-06-12
Vaginal self-sampling with HPV-DNA tests is a promising primary screening method for cervical cancer. However, women's experiences, concerns and the acceptability of such tests in low-resource settings remain unknown. In India, Nicaragua, and Uganda, a mixed-method design was used to collect data from surveys (N = 3,863), qualitative interviews (N = 72; 20 providers and 52 women) and focus groups (N = 30 women) on women's and providers' experiences with self-sampling, women's opinions of sampling at home, and their future needs. Among surveyed women, 90% provided a self- collected sample. Of these, 75% reported it was easy, although 52% were initially concerned about hurting themselves and 24% were worried about not getting a good sample. Most surveyed women preferred self-sampling (78%). However it was not clear if they responded to the privacy of self-sampling or the convenience of avoiding a pelvic examination, or both. In follow-up interviews, most women reported that they didn't mind self-sampling, but many preferred to have a provider collect the vaginal sample. Most women also preferred clinic-based screening (as opposed to home-based self-sampling), because the sample could be collected by a provider, women could receive treatment if needed, and the clinic was sanitary and provided privacy. Self-sampling acceptability was higher when providers prepared women through education, allowed women to examine the collection brush, and were present during the self-collection process. Among survey respondents, aids that would facilitate self-sampling in the future were: staff help (53%), additional images in the illustrated instructions (31%), and a chance to practice beforehand with a doll/model (26%). Self-and vaginal-sampling are widely acceptable among women in low-resource settings. Providers have a unique opportunity to educate and prepare women for self-sampling and be flexible in accommodating women's preference for self-sampling.
Thermoelectric properties of higher manganese silicide/multi-walled carbon nanotube composites.
Truong, D Y Nhi; Kleinke, Holger; Gascoin, Franck
2014-10-28
Composites made of Higher Manganese Silicide (HMS)-based compound MnSi1.75Ge0.02 and multi-walled carbon nanotubes (MWCNTs) were prepared by an easy and effective method including mechanical milling under mild conditions and reactive spark plasma sintering. SEM compositional mappings show a homogeneous dispersion of MWCNTs in the HMS matrix. Electronic and thermal transport properties were measured from room temperature to 875 K. While power factors are virtually unchanged by the addition of MWCNTs, the lattice thermal conductivity is significantly reduced by about 30%. As a consequence, the maximum figure of merit for the composites with 1 wt% MWCNTs is improved by about 20% compared to the MWCNT free HMS-based sample.
Using Conversational Learning to Enhance Teaching of Diversity
ERIC Educational Resources Information Center
Dawson, Gail A.
2013-01-01
To function in today's diverse and multicultural environment, workers must be properly prepared; yet teaching diversity is not an easy task. This article explores some of the challenges of diversity and proposes the use of conversational learning to make teaching more effective in preparing students and employees for the workplace. In addition, a…
ClassPrep: A Peer Review System for Class Preparation
ERIC Educational Resources Information Center
Park, Jooyong
2017-01-01
Class preparation is recommended by instructors in most college courses, but checking whether a student does so is not easy. A new blended learning system, named ClassPrep, has been proposed and implemented. The usability of the system was examined for two undergraduate psychology courses: one advanced course (n = 11) and one introductory course…
Practicable group testing method to evaluate weight/weight GMO content in maize grains.
Mano, Junichi; Yanaka, Yuka; Ikezu, Yoko; Onishi, Mari; Futo, Satoshi; Minegishi, Yasutaka; Ninomiya, Kenji; Yotsuyanagi, Yuichi; Spiegelhalter, Frank; Akiyama, Hiroshi; Teshima, Reiko; Hino, Akihiro; Naito, Shigehiro; Koiwa, Tomohiro; Takabatake, Reona; Furui, Satoshi; Kitta, Kazumi
2011-07-13
Because of the increasing use of maize hybrids with genetically modified (GM) stacked events, the established and commonly used bulk sample methods for PCR quantification of GM maize in non-GM maize are prone to overestimate the GM organism (GMO) content, compared to the actual weight/weight percentage of GM maize in the grain sample. As an alternative method, we designed and assessed a group testing strategy in which the GMO content is statistically evaluated based on qualitative analyses of multiple small pools, consisting of 20 maize kernels each. This approach enables the GMO content evaluation on a weight/weight basis, irrespective of the presence of stacked-event kernels. To enhance the method's user-friendliness in routine application, we devised an easy-to-use PCR-based qualitative analytical method comprising a sample preparation step in which 20 maize kernels are ground in a lysis buffer and a subsequent PCR assay in which the lysate is directly used as a DNA template. This method was validated in a multilaboratory collaborative trial.
Larson, Tuula; Östman, Conny; Colmsjö, Anders
2011-04-01
The monitoring of radioactive xenon isotopes is one of the principal methods for the detection of nuclear explosions in order to identify clandestine nuclear testing. In this work, a miniaturized, multiple-oven, six-column, preparative gas chromatograph was constructed in order to isolate trace quantities of radioactive xenon isotopes from ambient air, utilizing nitrogen as the carrier gas. The multidimensional chromatograph comprised preparative stainless steel columns packed with molecular sieves, activated carbon, and synthetic carbon adsorbents (e.g., Anasorb®-747 and Carbosphere®). A combination of purification techniques--ambient adsorption, thermal desorption, back-flushing, thermal focusing, and heart cutting--was selectively optimized to produce a well-defined xenon peak that facilitated reproducible heart cutting and accurate quantification. The chromatographic purification of a sample requires approximately 4 h and provides complete separation of xenon from potentially interfering components (such as water vapor, methane, carbon dioxide, and radon) with recovery and accuracy close to 100%. The preparative enrichment process isolates and concentrates a highly purified xenon gas fraction that is suitable for subsequent ultra-low-level γ-, ß/γ-spectroscopic or high-resolution mass spectrometric measurement (e.g., to monitor the gaseous fission products of nuclear explosions at remote locations). The Xenon Processing Unit is a free-standing, relatively lightweight, and transportable system that can be interfaced to a variety of sampling and detection systems. It has a relatively inexpensive, rugged, and compact modular (19-inch rack) design that provides easy access to all parts for maintenance and has a low power requirement.
Kueseng, Pamornrat; Pawliszyn, Janusz
2013-11-22
A new thin-film, carboxylated multiwalled carbon nanotubes/polydimethylsiloxane (MWCNTs-COOH/PDMS) coating was developed for 96-blade solid-phase microextraction (SPME) system followed by high performance liquid chromatography with ultraviolet detection (HPLC-UV). The method provided good extraction efficiency (64-90%) for three spiked levels, with relative standard deviations (RSD)≤6%, and detection limits between 1 and 2 μg/L for three phenolic compounds. The MWCNTs-COOH/PDMS 96-blade SPME system presents advantages over traditional methods due to its simplicity of use, easy coating preparation, low cost and high sample throughput (2.1 min per sample). The developed coating is reusable for a minimum of 110 extractions with good extraction efficiency. The coating provided higher extraction efficiency (3-8 times greater) than pure PDMS coatings. Copyright © 2013 Elsevier B.V. All rights reserved.
Immunoanalysis Methods for the Detection of Dioxins and Related Chemicals
Tian, Wenjing; Xie, Heidi Qunhui; Fu, Hualing; Pei, Xinhui; Zhao, Bin
2012-01-01
With the development of biotechnology, approaches based on antibodies, such as enzyme-linked immunosorbent assay (ELISA), active aryl hydrocarbon immunoassay (Ah-I) and other multi-analyte immunoassays, have been utilized as alternatives to the conventional techniques based on gas chromatography and mass spectroscopy for the analysis of dioxin and dioxin-like compounds in environmental and biological samples. These screening methods have been verified as rapid, simple and cost-effective. This paper provides an overview on the development and application of antibody-based approaches, such as ELISA, Ah-I, and multi-analyte immunoassays, covering the sample extraction and cleanup, antigen design, antibody preparation and immunoanalysis. However, in order to meet the requirements for on-site fast detection and relative quantification of dioxins in the environment, further optimization is needed to make these immuno-analytical methods more sensitive and easy to use. PMID:23443395
Rapid bacterial diagnostics via surface enhanced Raman microscopy.
Premasiri, W R; Sauer-Budge, A F; Lee, J C; Klapperich, C M; Ziegler, L D
2012-06-01
There is a continuing need to develop new techniques for the rapid and specific identification of bacterial pathogens in human body fluids especially given the increasing prevalence of drug resistant strains. Efforts to develop a surface enhanced Raman spectroscopy (SERS) based approach, which encompasses sample preparation, SERS substrates, portable Raman microscopy instrumentation and novel identification software, are described. The progress made in each of these areas in our laboratory is summarized and illustrated by a spiked infectious sample for urinary tract infection (UTI) diagnostics. SERS bacterial spectra exhibit both enhanced sensitivity and specificity allowing the development of an easy to use, portable, optical platform for pathogen detection and identification. SERS of bacterial cells is shown to offer not only reproducible molecular spectroscopic signatures for analytical applications in clinical diagnostics, but also is a new tool for studying biochemical activity in real time at the outer layers of these organisms.
ERIC Educational Resources Information Center
Brown, W. S.
1970-01-01
Illustrates a compromise between vertical and horizontal typographies which should make speed reading faster and more reliable, and suggests that computers could prepare text according to this arrangement. (MB)
Solid state NMR: The essential technology for helical membrane protein structural characterization
Cross, Timothy A.; Ekanayake, Vindana; Paulino, Joana; Wright, Anna
2014-01-01
NMR spectroscopy of helical membrane proteins has been very challenging on multiple fronts. The expression and purification of these proteins while maintaining functionality has consumed countless graduate student hours. Sample preparations have depended on whether solution or solid-state NMR spectroscopy was to be performed – neither have been easy. In recent years it has become increasingly apparent that membrane mimic environments influence the structural result. Indeed, in these recent years we have rediscovered that Nobel laureate, Christian Anfinsen, did not say that protein structure was exclusively dictated by the amino acid sequence, but rather by the sequence in a given environment (Anfinsen, 1973) [106]. The environment matters, molecular interactions with the membrane environment are significant and many examples of distorted, non-native membrane protein structures have recently been documented in the literature. However, solid-state NMR structures of helical membrane proteins in proteoliposomes and bilayers are proving to be native structures that permit a high resolution characterization of their functional states. Indeed, solid-state NMR is uniquely able to characterize helical membrane protein structures in lipid environments without detergents. Recent progress in expression, purification, reconstitution, sample preparation and in the solid-state NMR spectroscopy of both oriented samples and magic angle spinning samples has demonstrated that helical membrane protein structures can be achieved in a timely fashion. Indeed, this is a spectacular opportunity for the NMR community to have a major impact on biomedical research through the solid-state NMR spectroscopy of these proteins. PMID:24412099
Solid state NMR: The essential technology for helical membrane protein structural characterization
NASA Astrophysics Data System (ADS)
Cross, Timothy A.; Ekanayake, Vindana; Paulino, Joana; Wright, Anna
2014-02-01
NMR spectroscopy of helical membrane proteins has been very challenging on multiple fronts. The expression and purification of these proteins while maintaining functionality has consumed countless graduate student hours. Sample preparations have depended on whether solution or solid-state NMR spectroscopy was to be performed - neither have been easy. In recent years it has become increasingly apparent that membrane mimic environments influence the structural result. Indeed, in these recent years we have rediscovered that Nobel laureate, Christian Anfinsen, did not say that protein structure was exclusively dictated by the amino acid sequence, but rather by the sequence in a given environment (Anfinsen, 1973) [106]. The environment matters, molecular interactions with the membrane environment are significant and many examples of distorted, non-native membrane protein structures have recently been documented in the literature. However, solid-state NMR structures of helical membrane proteins in proteoliposomes and bilayers are proving to be native structures that permit a high resolution characterization of their functional states. Indeed, solid-state NMR is uniquely able to characterize helical membrane protein structures in lipid environments without detergents. Recent progress in expression, purification, reconstitution, sample preparation and in the solid-state NMR spectroscopy of both oriented samples and magic angle spinning samples has demonstrated that helical membrane protein structures can be achieved in a timely fashion. Indeed, this is a spectacular opportunity for the NMR community to have a major impact on biomedical research through the solid-state NMR spectroscopy of these proteins.
Wu, Yin-Liang; Chen, Ruo-Xia; Zhu, Lie; Lv, Yan; Zhu, Yong; Zhao, Jian
2016-02-15
A new analytical method for the determination of ribavirin in chicken muscle using a QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method and liquid chromatography-tandem mass spectrometry (LC-MS-MS) was developed and validated. Samples were extracted with acidified methanol (methanol:acetic acid, 99:1, v/v). The extract was further purified by QuEChERS method using primary-secondary amine (PSA) and C18. Finally, the extract was dried by nitrogen under 45°C and reconstituted in water. The separation was performed on a Hypercarb analytical column under a gradient elution. The mobile phase was composed of water buffered with ammonium acetate (2.0mM) and acetonitrile. The proposed method was validated according to the European Commission Decision 2002/657/EC. The values of the decision limit (CCα) and the detection capability (CCβ) were 1.1 and 1.5μg/kg, respectively. The mean recoveries of ribavirin ranged from 94.2% to 99.2%. The repeatability (expressed as coefficient of variation, CVr) of the method ranged from 4.5% to 4.9% and the reproducibility (CVR) of the method ranged from 4.8% to 5.4%. The method is demonstrated to be suitable for the determination of ribavirin in chicken muscle in conformity with the current EU performance requirements through validation. The total time required for the analysis of one sample, including sample preparation, was about 45min. Copyright © 2016 Elsevier B.V. All rights reserved.
Rani, Susheela; Malik, Ashok K; Singh, Baldev
2012-02-01
A method for the simultaneous determination of the antiepileptic drugs, phenobarbital (PHB), phenytoin (PTN), carbamazepine (CBZ), primidone (PRM) and oxcarbazepine (OXC) in human plasma and urine samples by using micro-extraction in a packed syringe as the sample preparation method connected with LC/UV (MEPS/LC/UV) is described. Micro-extraction in a packed syringe (MEPS) is a new miniaturized, solid-phase extraction technique that can be connected online to gas or liquid chromatography without any modifications. In MEPS approximately 1 mg of the solid packing material is inserted into a syringe (100-250 μL) as a plug. Sample preparation takes place on the packed bed. The bed can be coated to provide selective and suitable sampling conditions. The new method is very promising, easy to use, fully automated, inexpensive and quick. The standard curves were obtained within the concentration range 1-500 ng/mL in both plasma and urine samples. The results showed high correlation coefficients (R(2) >0.988) for all of the analytes within the calibration range. The extraction recovery was found to be between 88.56 and 99.38%. The limit of quantification was found to be between 0.132 and 1.956 ng/mL. The precision (RSD) values of quality control samples (QC) had a maximum deviation of 4.9%. A comparison of the detection limits with similar methods indicates high sensitivity of the present method. The method is applied for the analysis of these drugs in real urine and plasma samples of epileptic patients. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kovatsi, Leda; Rentifis, Konstantinos; Giannakis, Dimitrios; Njau, Samuel; Samanidou, Victoria
2011-07-01
The availability of a sensitive and rapid analytical method for the determination of opiates, and other substances of forensic interest, in a variety of biological specimens is of utmost importance to forensic laboratories. Solid-phase extraction is very popular in the pre-treatment of forensic samples. Nevertheless, a new approach, disposable pipette extraction (DPX), is gaining increasing interest in sample preparation. DPX has already been applied to the analysis of drugs of abuse in common biological matrices, such as urine and blood, but has not yet been evaluated on alternative biological samples, such as vitreous humor. The objective of this study was to evaluate the applicability of DPX on the analysis of opiates in vitreous humor. The currently developed method is fast, reliable, and easy to perform. The sensitivity, precision, and accuracy are satisfactory. Recoveries obtained are within the range of 72-91%, whereas the sample volume of vitreous humor required is only 100 μL. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Andrade, G C R M; Monteiro, S H; Francisco, J G; Figueiredo, L A; Botelho, R G; Tornisielo, V L
2015-05-15
A quick and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method, using dynamic multiple reaction monitoring and a 1.8-μm particle size analytical column, was developed to determine 57 pesticides in tomato in a 13-min run. QuEChERS (quick, easy, cheap, effective, rugged, and safe) method for samples preparations and validations was carried out in compliance with EU SANCO guidelines. The method was applied to 58 tomato samples. More than 84% of the compounds investigated showed limits of detection equal to or lower than 5 mg kg(-1). A mild (<20%), medium (20-50%), and strong (>50%) matrix effect was observed for 72%, 25%, and 3% of the pesticides studied, respectively. Eighty-one percent of the pesticides showed recoveries ranging between 70% and 120%. Twelve pesticides were detected in 35 samples, all below the maximum residue levels permitted in the Brazilian legislation; 15 samples exceeded the maximum residue levels established by the EU legislation for methamidophos; and 10 exceeded limits for acephate and four for bromuconazole. Copyright © 2014 Elsevier Ltd. All rights reserved.
Rapid detection of Listeria monocytogenes in foods, by a combination of PCR and DNA probe.
Ingianni, A; Floris, M; Palomba, P; Madeddu, M A; Quartuccio, M; Pompei, R
2001-10-01
Listeria monocytogenes is a frequent contaminant of water and foods. Its rapid detection is needed before some foods can be prepared for marketing. In this work L. monocytogenes has been searched for in foods, by a combination of polymerase chain reaction (PCR) and a DNA probe. Both PCR and the probe were prepared for recognizing a specific region of the internalin gene, which is responsible for the production of one of the most important pathogenic factors of Listeria. The combined use of PCR and the DNA probe was used for the detection of L. monocytogenes in over 180 environmental and food samples. Several detection methods were compared in this study, namely conventional culture methods; direct PCR; PCR after an enrichment step; a DNA probe alone; a DNA probe after enrichment and another commercially available gene-probe. Finally PCR and the DNA probe were used in series on all the samples collected. When the DNA probe was associated with the PCR, specific and accurate detection of listeria in the samples could be obtained in about a working-day. The present molecular method showed some advantages in terms of rapidity and specificity in comparison to the other aforementioned tests. In addition, it resulted as being easy to handle, even for non-specialized personnel in small diagnostic microbiology laboratories. Copyright 2001 Academic Press.
Sport Management Internships: Agency Perspectives, Expectations, and Concerns
ERIC Educational Resources Information Center
Williams, Jo
2004-01-01
Should we hire a sport management intern in our organization or department? What role will the intern play? How will we benefit? What can we expect from sport management interns in terms of preparation and commitment? How easy is it to find, select, and work with an appropriately prepared intern? Professionals ask all of these questions when they…
1977-09-01
the needed knowledge and skills must be provided. Ideally, these programs should be self- contained , capable of easy administration within...type of vehicle, duplicate cards were prepared. In effect, a task file was prepared, the file containing cards which described the task and...test situation contains a description of the situation. (If the operator does not actually encounter the situation, the situation is read to him by
Eberlin, Livia S; Abdelnur, Patricia V; Passero, Alan; de Sa, Gilberto F; Daroda, Romeu J; de Souza, Vanderlea; Eberlin, Marcos N
2009-08-01
High performance thin layer chromatography (HPTLC) combined with on-spot detection and characterization via easy ambient sonic-spray ionization mass spectrometry (EASI-MS) is applied to the analysis of biodiesel (B100) and biodiesel-petrodiesel blends (BX). HPTLC provides chromatographic resolution of major components whereas EASI-MS allows on-spot characterization performed directly on the HPTLC surface at ambient conditions. Constituents (M) are detected by EASI-MS in a one component-one ion fashion as either [M + Na](+) or [M + H](+). For both B100 and BX samples, typical profiles of fatty acid methyl esters (FAME) detected as [FAME + Na](+) ions allow biodiesel typification. The spectrum of the petrodiesel spot displays a homologous series of protonated alkyl pyridines which are characteristic for petrofuels (natural markers). The spectrum for residual or admixture oil spots is characterized by sodiated triglycerides [TAG + Na](+). The application of HPTLC to analyze B100 and BX samples and its combination with EASI-MS for on-spot characterization and quality control is demonstrated.
Preparation of stable silica surfaces for surface forces measurement
NASA Astrophysics Data System (ADS)
Ren, Huai-Yin; Mizukami, Masashi; Kurihara, Kazue
2017-09-01
A surface forces apparatus (SFA) measures the forces between two surfaces as a function of the surface separation distance. It is regarded as an essential tool for studying the interactions between two surfaces. However, sample surfaces used for the conventional SFA measurements have been mostly limited to thin (ca. 2-3 μm) micas, which are coated with silver layers (ca. 50 nm) on their back, due to the requirement of the distance determination by transmission mode optical interferometry called FECO (fringes of equal chromatic order). The FECO method has the advantage of determining the absolute distance, so it should be important to increase the availability of samples other than mica, which is chemically nonreactive and also requires significant efforts for cleaving. Recently, silica sheets have been occasionally used in place of mica, which increases the possibility of surface modification. However, in this case, the silver layer side of the sheet is glued on a cylindrical quartz disc using epoxy resin, which is not stable in organic solvents and can be easily swollen or dissolved. The preparation of substrates more stable under severe conditions, such as in organic solvents, is necessary for extending application of the measurement. In this study, we report an easy method for preparing stable silica layers of ca. 2 μm in thickness deposited on gold layers (41 nm)/silica discs by sputtering, then annealed to enhance the stability. The obtained silica layers were stable and showed no swelling in organic solvents such as ethanol and toluene.
A method of mounting multiple otoliths for beam-based microchemical analyses
Donohoe, C.J.; Zimmerman, C.E.
2010-01-01
Beam-based analytical methods are widely used to measure the concentrations of elements and isotopes in otoliths. These methods usually require that otoliths be individually mounted and prepared to properly expose the desired growth region to the analytical beam. Most analytical instruments, such as LA-ICPMS and ion and electron microprobes, have sample holders that will accept only one to six slides or mounts at a time. We describe a method of mounting otoliths that allows for easy transfer of many otoliths to a single mount after they have been prepared. Such an approach increases the number of otoliths that can be analyzed in a single session by reducing the need open the sample chamber to exchange slides-a particularly time consuming step on instruments that operate under vacuum. For ion and electron microprobes, the method also greatly reduces the number of slides that must be coated with an electrical conductor prior to analysis. In this method, a narrow strip of cover glass is first glued at one end to a standard microscope slide. The otolith is then mounted in thermoplastic resin on the opposite, free end of the strip. The otolith can then be ground and flipped, if needed, by reheating the mounting medium. After otolith preparation is complete, the cover glass is cut with a scribe to free the otolith and up to 20 small otoliths can be arranged on a single petrographic slide. ?? 2010 The Author(s).
Shivaraju, H P; Byrappa, K
2012-07-01
This work deals with the non-biodegradable micro-pollutants degradation by supported photocatalyst based heterogeneous photocatalytic reaction. TiO2 based supported photocatalyst was prepared by the hydrothermal technique to improve the photocatalytic performance along with easy recovery of suspended photocatalyst from aqueous medium after photoreaction. TO2 deposited calcium alumino-silicate beads (CASB) supports were prepared under mild hydrothermal conditions (Temparature-200 degrees C, Duration-24 h). In the present study, industrial dyes such as Amaranth and Brilliant Yellow were used as model micro-pollutants in aqueous solution. A real time pesticide industrial effluent was tested for its photocatalytic removal of organic pollutants using TO2 deposited CASB supported photocatalytic composite as an effective photocatalyst. Photocatalytic degradation of micro-pollutants present in aqueous medium was carried out in a batch photoreactor, at atmospheric pressure and temperature (28 degrees C). The influence of different light sources, irradiation time, catalyst load and catalytic performance is discussed. The photocatalytic degradation of micro-pollutants in aqueous medium was evaluated by determination of COD and %T. Easy separation and recovery of suspended photocatalysts from aqueous solution is the major advantage of hydrothermally prepared supported photocatalytic composite.
Kostanyan, Artak E; Shishilov, Oleg N
2018-06-01
Multiple dual mode counter-current chromatography (MDM CCC) separation processes with semi-continuous large sample loading consist of a succession of two counter-current steps: with "x" phase (first step) and "y" phase (second step) flow periods. A feed mixture dissolved in the "x" phase is continuously loaded into a CCC machine at the beginning of the first step of each cycle over a constant time with the volumetric rate equal to the flow rate of the pure "x" phase. An easy-to-use calculating machine is developed to simulate the chromatograms and the amounts of solutes eluted with the phases at each cycle for steady-state (the duration of the flow periods of the phases is kept constant for all the cycles) and non-steady-state (with variable duration of alternating phase elution steps) separations. Using the calculating machine, the separation of mixtures containing up to five components can be simulated and designed. Examples of the application of the calculating machine for the simulation of MDM CCC processes are discussed. Copyright © 2018 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zuo, Wen-Liang, E-mail: wlzuo@iphy.ac.cn, E-mail: shenbg@aphy.iphy.ac.cn; Liu, Rong-Ming; Zheng, Xin-Qi
2014-05-07
The textured Pr{sub 2}Fe{sub 14}B nanoflakes were produced by surfactant-assisted ball milling (SABM). Single phase tetragonal structure was characterized for the samples before and after SABM by X-ray diffraction (XRD). The thickness and length of the as-milled flakes are mainly in the range of 50–150 nm and 0.5–2 μm, respectively. For the field-aligned Pr{sub 2}Fe{sub 14}B nanoflakes, the out-of-plane texture (the easy magnetization direction (EMD) along the c-axis) is indicated from the increasing (00l) peaks in the XRD patterns. SEM image demonstrates that the EMD is parallel to flaky surface, which is different from the RCo{sub 5} (R = rare earth) system with EMDmore » perpendicular to the surface. We propose a hypothesis that the easy glide planes are related with the area of crystal planes. In addition, a large coercivity H{sub c} = 3.9 kOe is observed in the Pr{sub 2}Fe{sub 14}B flakes with strong texture.« less
Wang, Man; Cui, Shihai; Yang, Xiaodi; Bi, Wentao
2015-01-01
An easy preparation of g-C3N4/Fe3O4 nanocomposites by chemical co-precipitation has been demonstrated. The as-prepared materials were characterized by X-ray diffraction, transmission electron microscopy, Fourier transform infrared spectroscopy and thermogravimetric analysis. The high affinity of g-C3N4 toward polycyclic aromatic hydrocarbons and the magnetic behavior of Fe3O4 were combined to provide an efficient and simple magnetic solid phase extraction (MSPE). The adsorption and desorption of polycyclic aromatic hydrocarbons on g-C3N4/Fe3O4 were examined. Different factors affecting the magnetic solid phase extraction of polycyclic aromatic hydrocarbons were assessed in terms of adsorption, desorption, and recovery. Under the optimized conditions, the proposed method showed good limits of detection (LOD, S/N=3) in the range of 0.05-0.1 ng mL(-1) and precision in the range of 1.8-5.3% (RSDs, n=3). This method was also successfully applied to the analysis of real water samples; good spiked recoveries over the range of 80.0-99.8% were obtained. Copyright © 2014 Elsevier B.V. All rights reserved.
Riedel, Melanie; Speer, Karl; Stuke, Sven; Schmeer, Karl
2010-01-01
Since 2003, two new multipesticide residue methods for screening crops for a large number of pesticides, developed by Klein and Alder and Anastassiades et al. (Quick, Easy, Cheap, Effective, Rugged, and Safe; QuEChERS), have been published. Our intention was to compare these two important methods on the basis of their extraction efficiency, reproducibility, ruggedness, ease of use, and speed. In total, 70 pesticides belonging to numerous different substance classes were analyzed at two concentration levels by applying both methods, using five different representative matrixes. In the case of the QuEChERS method, the results of the three sample preparation steps (crude extract, extract after SPE, and extract after SPE and acidification) were compared with each other and with the results obtained with the Klein and Alder method. The extraction efficiencies of the QuEChERS method were far higher, and the sample preparation was much quicker when the last two steps were omitted. In most cases, the extraction efficiencies after the first step were approximately 100%. With extraction efficiencies of mostly less than 70%, the Klein and Alder method did not compare favorably. Some analytes caused problems during evaluation, mostly due to matrix influences.
Dormeyer, Wilma; van Hoof, Dennis; Mummery, Christine L; Krijgsveld, Jeroen; Heck, Albert J R
2008-10-01
The identification of (plasma) membrane proteins in cells can provide valuable insights into the regulation of their biological processes. Pluripotent cells such as human embryonic stem cells and embryonal carcinoma cells are capable of unlimited self-renewal and share many of the biological mechanisms that regulate proliferation and differentiation. The comparison of their membrane proteomes will help unravel the biological principles of pluripotency, and the identification of biomarker proteins in their plasma membranes is considered a crucial step to fully exploit pluripotent cells for therapeutic purposes. For these tasks, membrane proteomics is the method of choice, but as indicated by the scarce identification of membrane and plasma membrane proteins in global proteomic surveys it is not an easy task. In this minireview, we first describe the general challenges of membrane proteomics. We then review current sample preparation steps and discuss protocols that we found particularly beneficial for the identification of large numbers of (plasma) membrane proteins in human tumour- and embryo-derived stem cells. Our optimized assembled protocol led to the identification of a large number of membrane proteins. However, as the composition of cells and membranes is highly variable we still recommend adapting the sample preparation protocol for each individual system.
Preparation of decellularized vascular matrix by co-crosslinking of procyanidins and glutaraldehyde.
Wang, Xiaotong; Ma, Bing; Chang, Jiang
2015-01-01
Vascular extracellular matrices (vECMs) have shown potential for small-diameter blood vessel tissue engineering applications. However, problems such as chemical instability and easy calcification are still remained. Chemical crosslinking using crosslinkers such as glutaraldehyde (GA) can improve mechanical properties and proteolysis resistance of vECMs, but leads to calcification and cytotoxicity. Procyanidins (PC) can crosslink ECMs with anti-calcification property and cytocompatibility, but the mechanical properties and chemical stability are unsatisfactory. A novel co-crosslinking technique using PC and GA was developed, which combines the advantages of both PC and GA for enhancing mechanical properties and stability of vECMs with reduced calcification and cytotoxicity. Fresh carotid were decellularized and then crosslinked by PC and subsequent GA for 6 h respectively. The mechanical properties, dynamic release of PC, enzymatic degradation, calcification and cytotoxicity of crosslinked samples were evaluated. The co-crosslinked vECMs showed enhanced tensile strength, chemical and biological stability, comparable anti-calcification property as compared to pure PC-crosslinked samples. Cytotoxicity assay showed that the co-crosslinked vECMs were cytocompatible for supporting the adhesion and proliferation of HUVECs. Co-crosslinking with PC and GA might be a useful method for preparation of vECM scaffolds with potential applications in small-diameter blood vessel tissue engineering.
NASA Astrophysics Data System (ADS)
Mirabi, Ali; Dalirandeh, Zeinab; Rad, Ali Shokuhi
2015-05-01
A new method has been developed for the separation/preconcentration of trace level cadmium ions using diphenyl carbazone/sodium dodecyl sulfate immobilized on magnetic nanoparticle Fe3O4 as a new sorbent SPE and their determination by flame atomic absorption spectrometry (FAAS). Synthesized nanoparticle was characterized by scanning electron microscope (SEM) and transmission electron microscope (TEM). Various influencing parameters on the separation and preconcentration of trace level cadmium ions such as, pH value, amount of nanoparticles, amount of diphenyl carbazone, condition of eluting solution, the effects of matrix ions were examined. The cadmium ions can be eluted from the modified magnetic nanoparticle using 1 mol L-1 HCl as a desorption reagent. The detection limit of this method for cadmium was 3.71 ng ml-1 and the R.S.D. was 0.503% (n=6). The advantages of this new method include rapidity, easy preparation of sorbents and a high concentration factor. The proposed method has been applied to the determination of Cd ions at trace levels in real samples such as, green tea, rice, tobacco, carrot, lettuce, ginseng, spice, tap water, river water, sea water with satisfactory results.
The Effectiveness of SpeechEasy during Situations of Daily Living
ERIC Educational Resources Information Center
O'Donnell, Jennifer J.; Armson, Joy; Kiefte, Michael
2008-01-01
A multiple single-subject design was used to examine the effects of SpeechEasy on stuttering frequency in the laboratory and in longitudinal samples of speech produced in situations of daily living (SDL). Seven adults who stutter participated, all of whom had exhibited at least 30% reduction in stuttering frequency while using SpeechEasy during…
Evaluation of two fast and easy methods for pesticide residue analysis in fatty food matrixes.
Lehotay, Steven J; Mastovská, Katerina; Yun, Seon Jong
2005-01-01
Two rapid methods of sample preparation and analysis of fatty foods (e.g., milk, eggs, and avocado) were evaluated and compared for 32 pesticide residues representing a wide range of physicochemical properties. One method, dubbed the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method for pesticide residue analysis, entailed extraction of 15 g sample with 15 mL acetonitrile (MeCN) containing 1% acetic acid followed by addition of 6 g anhydrous magnesium sulfate and 1.5 g sodium acetate. After centrifugation, 1 mL of the buffered MeCN extract underwent a cleanup step (in a technique known as dispersive solid-phase extraction) using 50 mg each of C18 and primary secondary amine sorbents plus 150 mg MgSO4. The second method incorporated a form of matrix solid-phase dispersion (MSPD), in which 0.5 g sample plus 2 g C18 and 2 g anhydrous sodium sulfate was mixed in a mortar and pestle and added above a 2 g Florisil column on a vacuum manifold. Then, 5 x 2 mL MeCN was used to elute the pesticide analytes from the sample into a collection tube, and the extract was concentrated to 0.5 mL by evaporation. Extracts in both methods were analyzed concurrently by gas chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry. The recoveries of semi-polar and polar pesticides were typically 100% in both methods (except that basic pesticides, such as thiabendazole and imazalil, were not recovered in the MSPD method), but recovery of nonpolar pesticides decreased as fat content of the sample increased. This trend was more pronounced in the QuEChERS method, in which case the most lipophilic analyte tested, hexachlorobenzene, gave 27 +/- 1% recovery (n=6) in avocado (15% fat) with a<10 ng/g limit of quantitation.
Encapsulation of eugenol from clove oil using casein micelle for solid preparation
NASA Astrophysics Data System (ADS)
Wijayanto, Andri; Putri, Yeshinta Risky Priasmara; Hermansyah, Heri; Sahlan, Muhamad
2017-02-01
Liquid preparation of eugenol in clove oil form is one of eugenol preparation form that is easiest to get it nowadays in many level of purity. The problem is the liquid preparation of chemical is often not easy to handle than the solid one. In this study, we observe the effectivity of cow milk casein in case of encapsulating eugenol from clove oil for creating the solid preparation of eugenol in nanoscale size. The result is 63.86% eugenol from clove oil can be encapsulated by the casein. The average particle diameter is about 377.5 nm, with loading capacity until 67.2%.
Two New Nuclear Isolation Buffers for Plant DNA Flow Cytometry: A Test with 37 Species
Loureiro, João; Rodriguez, Eleazar; Doležel, Jaroslav; Santos, Conceição
2007-01-01
Background and Aims After the initial boom in the application of flow cytometry in plant sciences in the late 1980s and early 1990s, which was accompanied by development of many nuclear isolation buffers, only a few efforts were made to develop new buffer formulas. In this work, recent data on the performance of nuclear isolation buffers are utilized in order to develop new buffers, general purpose buffer (GPB) and woody plant buffer (WPB), for plant DNA flow cytometry. Methods GPB and WPB were used to prepare samples for flow cytometric analysis of nuclear DNA content in a set of 37 plant species that included herbaceous and woody taxa with leaf tissues differing in structure and chemical composition. The following parameters of isolated nuclei were assessed: forward and side light scatter, propidium iodide fluorescence, coefficient of variation of DNA peaks, quantity of debris background, and the number of particles released from sample tissue. The nuclear genome size of 30 selected species was also estimated using the buffer that performed better for a given species. Key Results In unproblematic species, the use of both buffers resulted in high quality samples. The analysis of samples obtained with GPB usually resulted in histograms of DNA content with higher or similar resolution than those prepared with the WPB. In more recalcitrant tissues, such as those from woody plants, WPB performed better and GPB failed to provide acceptable results in some cases. Improved resolution of DNA content histograms in comparison with previously published buffers was achieved in most of the species analysed. Conclusions WPB is a reliable buffer which is also suitable for the analysis of problematic tissues/species. Although GPB failed with some plant species, it provided high-quality DNA histograms in species from which nuclear suspensions are easy to prepare. The results indicate that even with a broad range of species, either GPB or WPB is suitable for preparation of high-quality suspensions of intact nuclei suitable for DNA flow cytometry. PMID:17684025
DASH Diet: Tips for Shopping and Cooking
... as deli meats. Condiments, seasonings and spreads . Herbs, spices, flavored vinegars, salsas and olive oil can add ... easy to prepare vegetables without butter or oil. Spice mill or garlic press . These items make it ...
A Citizen's Guide to Drycleaner Cleanup
The State Coalition for Remediation of Drycleaners (SCRD) has prepared an easy-to-read guide explaining the drycleaner cleanup process and describing the technologies that are most commonly used to clean up contaminated drycleaner sites.
Purple or Colorless--Which Way Up? An Entertaining Solubility Demonstration.
ERIC Educational Resources Information Center
Kitson, Trevor M.
2003-01-01
Presents an experiment that is quick and easy to prepare, visually striking, and amusing to students. Relates to several key chemical concepts including polarity, intermolecular forces, solubility, and spectrophotometry. (Author/NB)
Room temperature synthesis of agarose/sol-gel glass pieces with tailored interconnected porosity.
Cabañas, M V; Peña, J; Román, J; Vallet-Regí, M
2006-09-01
An original shaping technique has been applied to prepare porous bodies at room temperature. Agarose, a biodegradable polysaccharide, was added as binder of a sol-gel glass in powder form, yielding an easy to mold paste. Interconnected tailored porous bodies can be straightforwardly prepared by pouring the slurry into a polymeric scaffold, previously designed by stereolitography, which is subsequently eliminated by alkaline dissolution at room temperature. The so obtained pieces behave like a hydrogel with an enhanced consistency that makes them machinable and easy to manipulate. These materials generate an apatite-like layer when immersed in a simulated body fluid, indicating a potential in vivo bioactivity. The proposed method can be applied to different powdered materials to produce pieces, at room temperature, with various shapes and sizes and with tailored interconnected porosity.
Confidence Preserving Machine for Facial Action Unit Detection
Zeng, Jiabei; Chu, Wen-Sheng; De la Torre, Fernando; Cohn, Jeffrey F.; Xiong, Zhang
2016-01-01
Facial action unit (AU) detection from video has been a long-standing problem in automated facial expression analysis. While progress has been made, accurate detection of facial AUs remains challenging due to ubiquitous sources of errors, such as inter-personal variability, pose, and low-intensity AUs. In this paper, we refer to samples causing such errors as hard samples, and the remaining as easy samples. To address learning with the hard samples, we propose the Confidence Preserving Machine (CPM), a novel two-stage learning framework that combines multiple classifiers following an “easy-to-hard” strategy. During the training stage, CPM learns two confident classifiers. Each classifier focuses on separating easy samples of one class from all else, and thus preserves confidence on predicting each class. During the testing stage, the confident classifiers provide “virtual labels” for easy test samples. Given the virtual labels, we propose a quasi-semi-supervised (QSS) learning strategy to learn a person-specific (PS) classifier. The QSS strategy employs a spatio-temporal smoothness that encourages similar predictions for samples within a spatio-temporal neighborhood. In addition, to further improve detection performance, we introduce two CPM extensions: iCPM that iteratively augments training samples to train the confident classifiers, and kCPM that kernelizes the original CPM model to promote nonlinearity. Experiments on four spontaneous datasets GFT [15], BP4D [56], DISFA [42], and RU-FACS [3] illustrate the benefits of the proposed CPM models over baseline methods and state-of-the-art semisupervised learning and transfer learning methods. PMID:27479964
Fernandes, Gabriel D; Alberici, Rosana M; Pereira, Gustavo G; Cabral, Elaine C; Eberlin, Marcos N; Barrera-Arellano, Daniel
2012-12-01
Commercial lecithins are composed mainly of phospholipids and triacylglycerols. The analysis of the commercial lecithins, including their fraction of phospholipids, normally involves laborious and expensive protocols. Easy ambient sonic-spray ionization mass spectrometry (EASI-MS) is shown to be an efficient technique for the analysis of lipids. Samples of commercial lecithins including standards, refined, deoiled and modified soy lecithin were tested. Characteristic profiles of phosphatidylcholines and triacylglycerols are detected by EASI(+)-MS, whereas EASI(-)-MS provided phosphatidylethanolamines, glycophospholipids and free fatty acids profiles. Acetylated lecithins also displayed characteristic acetylated derivatives. EASI-MS data was also compared to MALDI-MS, and found to display richer compositional information. The industrial process applied to lecithin fabrication was also characterised via typical EASI-MS profiles. EASI-MS both in its positive and negative ion modes offers a direct, fast and efficient technique able to characterise commercial lecithin. Copyright © 2012 Elsevier Ltd. All rights reserved.
Cross-Validation of easyCBM Reading Cut Scores in Washington: 2009-2010. Technical Report #1109
ERIC Educational Resources Information Center
Irvin, P. Shawn; Park, Bitnara Jasmine; Anderson, Daniel; Alonzo, Julie; Tindal, Gerald
2011-01-01
This technical report presents results from a cross-validation study designed to identify optimal cut scores when using easyCBM[R] reading tests in Washington state. The cross-validation study analyzes data from the 2009-2010 academic year for easyCBM[R] reading measures. A sample of approximately 900 students per grade, randomly split into two…
NASA Astrophysics Data System (ADS)
Zhong, Lihua; He, Xiaoman; Qu, Jun; Li, Xuewei; Lei, Zhiwu; Zhang, Qiwu; Liu, Xinzhong
2017-01-01
Al(OH)3 and Ca(OH)2 powders are co-ground to prepare a precursor which hydrates into a layered double hydroxide (LDH) phase by agitation in aqueous solution with target hexavalent chromium (Cr(VI)) at room temperature, to achieve an obvious improvement in removal efficiency of Cr(VI) through an easy incorporation into the structure. Although the prepared precursor transforms into LDH phases also when agitated in the solutions of calcium and magnesium chlorides, it incorporates Cr(VI) preferentially to the chloride salts when they coexist. The adsorption isotherm and kinetic studies show that the phenomena occurring on the Al-Ca precursor fit a pseudo-second-order kinetics with a Langmuir adsorption capacity of 59.45 mg/g. Besides, characterizations of the prepared precursor and the samples after adsorption are also performed by X-ray diffraction (XRD), Fourier transform infrared (FT-IR), Transmission electron microscope (TEM) to understand the reason of the preferential incorporation of Cr(VI) to the coexisting chloride salts during the LDH phase formation. Ca-Al precursor (C3A) was agitated in a hexavalent chromium (Cr(VI)) solution to form Al-Ca-CrO4 LDH product. Ca-Al-CrO4 LDH phase occurred preferentially to Ca-Al-MCl2 LDH phases in the solutions of calcium and magnesium chlorides, it incorporates Cr(VI) preferentially to the chloride salts when they coexist.
Poetzsch, Michael; Steuer, Andrea E; Roemmelt, Andreas T; Baumgartner, Markus R; Kraemer, Thomas
2014-12-02
Single hair analysis normally requires extensive sample preparation microscale protocols including time-consuming steps like segmentation and extraction. Matrix assisted laser desorption and ionization mass spectrometric imaging (MALDI-MSI) was shown to be an alternative tool in single hair analysis, but still, questions remain. Therefore, an investigation of MALDI-MSI in single hair analysis concerning the extraction process, usage of internal standard (IS), and influences on the ionization processes were systematically investigated to enable the reliable application to hair analysis. Furthermore, single dose detection, quantitative correlation to a single hair, and hair strand LC-MS/MS results were performed, and the performance was compared to LC-MS/MS single hair monitoring. The MALDI process was shown to be independent from natural hair color and not influenced by the presence of melanin. Ionization was shown to be reproducible along and in between different hair samples. MALDI image intensities in single hair and hair snippets showed good semiquantitative correlation to zolpidem hair concentrations obtained from validated routine LC-MS/MS methods. MALDI-MSI is superior to LC-MS/MS analysis when a fast, easy, and cheap sample preparation is necessary, whereas LC-MS/MS showed higher sensitivity with the ability of single dose detection for zolpidem. MALDI-MSI and LC-MS/MS segmental single hair analysis showed good correlation, and both are suitable for consumption monitoring of drugs of abuse with a high time resolution.
Applying Lean Sigma solutions to mistake-proof the chemotherapy preparation process.
Aboumatar, Hanan J; Winner, Laura; Davis, Richard; Peterson, Aisha; Hill, Richard; Frank, Susan; Almuete, Virna; Leung, T Vivian; Trovitch, Peter; Farmer, Denise
2010-02-01
Errors related to high-alert medications, such as chemotherapeutic agents, have resulted in serious adverse events. A fast-paced application of Lean Sigma methodology was used to safeguard the chemotherapy preparation process against errors and increase compliance with United States Pharmacopeia 797 (USP 797) regulations. On Days 1 and 2 of a Lean Sigma workshop, frontline staff studied the chemotherapy preparation process. During Days 2 and 3, interventions were developed and implementation was started. The workshop participants were satisfied with the speed at which improvements were put to place using the structured workshop format. The multiple opportunities for error identified related to the chemotherapy preparation process, workspace layout, distractions, increased movement around ventilated hood areas, and variation in medication processing and labeling procedures. Mistake-proofing interventions were then introduced via workspace redesign, process redesign, and development of standard operating procedures for pharmacy staff. Interventions were easy to implement and sustainable. Reported medication errors reaching patients and requiring monitoring decreased, whereas the number of reported near misses increased, suggesting improvement in identifying errors before reaching the patients. Application of Lean Sigma solutions enabled the development of a series of relatively inexpensive and easy to implement mistake-proofing interventions that reduce the likelihood of chemotherapy preparation errors and increase compliance with USP 797 regulations. The findings and interventions are generalizable and can inform mistake-proofing interventions in all types of pharmacies.
Jafari, Mohammad T; Riahi, Farhad
2014-05-23
The capability of corona discharge ionization ion mobility spectrometry (CD-IMS) for direct analysis of the samples extracted by dispersive liquid-liquid microextraction (DLLME) was investigated and evaluated, for the first time. To that end, an appropriate new injection port was designed and constructed, resulting in possibility of direct injection of the known sample volume, without tedious sample preparation steps (e.g. derivatization, solvent evaporation, and re-solving in another solvent…). Malathion as a test compound was extracted from different matrices by a rapid and convenient DLLME method. The positive ion mobility spectra of the extracted malathion were obtained after direct injection of carbon tetrachloride or methanol solutions. The analyte responses were compared and the statistical results revealed the feasibility of direct analysis of the extracted samples in carbon tetrachloride, resulting in a convenient methodology. The coupled method of DLLME-CD-IMS was exhaustively validated in terms of sensitivity, dynamic range, recovery, and enrichment factor. Finally, various real samples of apple, river and underground water were analyzed, all verifying the feasibility and success of the proposed method for the easy extraction of the analyte using DLLME separation before the direct analysis by CD-IMS. Copyright © 2014 Elsevier B.V. All rights reserved.
An air-stable Na 3SbS 4 superionic conductor prepared by a rapid and economic synthetic procedure
Wang, Hui; Chen, Yan; Hood, Zachary D.; ...
2016-01-01
All-solid-state sodium batteries, using abundant sodium resources and solid electrolyte, hold much promise for safe, low cost, large-scale energy storage. To realize the practical applications of all solid Na-ion batteries at ambient temperature, the solid electrolytes are required to have high ionic conductivity, chemical stability, and ideally, easy preparation. Ceramic electrolytes show higher ionic conductivity than polymers, but they often require extremely stringent synthesis conditions, either high sintering temperature above 1000 C or long-time, low-energy ball milling. Herein, we report a new synthesis route for Na 3SbS 4, a novel Na superionic conductor that needs much lower processing temperature belowmore » 200 C and easy operation. This new solid electrolyte exhibits a remarkable ionic conductivity of 1.05 mS cm -1 at 25 °C and is chemically stable under ambient atmosphere. In conclusion, this synthesis process provides unique insight into the current state-of-the-art solid electrolyte preparation and opens new possibilities for the design of similar materials.« less
Yang, Qian; Ke, Yini; Luo, Jianhong; Tang, Yang
2017-02-01
primary hippocampal neuron cultures allow for subcellular morphological dissection, easy access to drug treatment and electrophysiology analysis of individual neurons, and is therefore an ideal model for the study of neuron physiology. While neuron and glia mixed cultures are relatively easy to prepare, pure neurons are particular hard to culture at low densities which are suitable for morphology studies. This may be due to a lack of neurotrophic factors such as brain derived neurotrophic factor (BDNF), neurotrophin-3 (NT3) and Glial cell line-derived neurotrophic factor (GDNF). In this study we used a two step protocol in which neuron-glia mixed cultures were initially prepared for maturation to support the growth of young neurons plated at very low densities. Our protocol showed that neurotrophic support resulted in physiologically functional hippocampal neurons with larger cell body, increased neurite length and decreased branching and complexity compared to cultures prepared using a conventional method. Our protocol provides a novel way to culture highly uniformed hippocampal neurons for acquiring high quality, neuron based data. Copyright © 2016 Elsevier B.V. All rights reserved.
Ultrasonic-based membrane aided sample preparation of urine proteomes.
Jesus, Jemmyson Romário; Santos, Hugo M; López-Fernández, H; Lodeiro, Carlos; Arruda, Marco Aurélio Zezzi; Capelo, J L
2018-02-01
A new ultrafast ultrasonic-based method for shotgun proteomics as well as label-free protein quantification in urine samples is developed. The method first separates the urine proteins using nitrocellulose-based membranes and then proteins are in-membrane digested using trypsin. The enzymatic digestion process is accelerated from overnight to four minutes using a sonoreactor ultrasonic device. Overall, the sample treatment pipeline comprising protein separation, digestion and identification is done in just 3h. The process is assessed using urine of healthy volunteers. The method shows that male can be differentiated from female using the protein content of urine in a fast, easy and straightforward way. 232 and 226 proteins are identified in urine of male and female, respectively. From this, 162 are common to both genders, whilst 70 are unique to male and 64 to female. From the 162 common proteins, 13 are present at levels statistically different (p < 0.05). The method matches the analytical minimalism concept as outlined by Halls, as each stage of this analysis is evaluated to minimize the time, cost, sample requirement, reagent consumption, energy requirements and production of waste products. Copyright © 2017 Elsevier B.V. All rights reserved.
Cross-Validation of easyCBM Reading Cut Scores in Oregon: 2009-2010. Technical Report #1108
ERIC Educational Resources Information Center
Park, Bitnara Jasmine; Irvin, P. Shawn; Anderson, Daniel; Alonzo, Julie; Tindal, Gerald
2011-01-01
This technical report presents results from a cross-validation study designed to identify optimal cut scores when using easyCBM[R] reading tests in Oregon. The cross-validation study analyzes data from the 2009-2010 academic year for easyCBM[R] reading measures. A sample of approximately 2,000 students per grade, randomly split into two groups of…
Construction of helper plasmid-mediated dual-display phage for autoantibody screening in serum.
Rajaram, Kaushik; Vermeeren, Veronique; Somers, Klaartje; Somers, Veerle; Michiels, Luc
2014-01-01
M13 filamentous bacteriophage has been used in displaying disease-specific antibodies, biomarkers, and peptides. One of the major drawbacks of using phage in diagnostic assays is the aspecific adsorption of proteins leading to a high background signal and decreasing sensitivity. To deal with this, we developed a genetically pure, exchangeable dual-display phage system in which biomarkers and streptavidin-binding protein (SBP) are displayed at opposite ends of the phage. This approach allows for sample purification, using streptavidin-coated magnetic beads resulting in a higher sensitivity of signal detection assays. Our dual-display cassette system approach also allows for easy exchange of both the anchor protein (SBP) and the displayed biomarker. The presented principle is applied for the detection of antibody reactivity against UH-RA.21 which is a good candidate biomarker for rheumatoid arthritis (RA). The applicability of dual-display phage preparation using a helper plasmid system is demonstrated, and its increased sensitivity in phage ELISA assays using patient serum samples is shown.
Nabais, J M Valente; Teixeira, Jorge Ginja; Almeida, I
2011-02-01
The aim of the work now reported is the development of low cost electrodes in the monolithic shape without the need for a pos-production step with potential to be used in supercapacitors. The tested materials were activated carbon fibres prepared and activated carbons made from coffee endocarp. The main functional groups identified were quinone, lactone, Si-H, phenol, hydroxyl, carbonyl and ether for activated carbon samples and amine, amide, pyrone, lactone, carbonyl and hydroxyl for activated carbon fibres samples. The nanostructure of the materials is predominantly microporous but with a significant variety of porosity development with BET surface area and pore volume given by α(s) method range from 89 to 1050 m(2) g(-1) and 0.04 to 0.50 cm(3) g(-1), respectively. The electrochemical properties of the materials were investigated using classic cyclic voltammetry, chronopotentiometry and electrochemical impedance spectroscopy. The higher specific capacitance achieved was 176 F g(-1). Copyright © 2010 Elsevier Ltd. All rights reserved.
Pan, Hong-Wei; Li, Wei; Li, Rong-Guo; Li, Yong; Zhang, Yi; Sun, En-Hua
2018-01-01
Rapid identification and determination of the antibiotic susceptibility profiles of the infectious agents in patients with bloodstream infections are critical steps in choosing an effective targeted antibiotic for treatment. However, there has been minimal effort focused on developing combined methods for the simultaneous direct identification and antibiotic susceptibility determination of bacteria in positive blood cultures. In this study, we constructed a lysis-centrifugation-wash procedure to prepare a bacterial pellet from positive blood cultures, which can be used directly for identification by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) and antibiotic susceptibility testing by the Vitek 2 system. The method was evaluated using a total of 129 clinical bacteria-positive blood cultures. The whole sample preparation process could be completed in <15 min. The correct rate of direct MALDI-TOF MS identification was 96.49% for gram-negative bacteria and 97.22% for gram-positive bacteria. Vitek 2 antimicrobial susceptibility testing of gram-negative bacteria showed an agreement rate of antimicrobial categories of 96.89% with a minor error, major error, and very major error rate of 2.63, 0.24, and 0.24%, respectively. Category agreement of antimicrobials against gram-positive bacteria was 92.81%, with a minor error, major error, and very major error rate of 4.51, 1.22, and 1.46%, respectively. These results indicated that our direct antibiotic susceptibility analysis method worked well compared to the conventional culture-dependent laboratory method. Overall, this fast, easy, and accurate method can facilitate the direct identification and antibiotic susceptibility testing of bacteria in positive blood cultures.
Extension of an Object-Oriented Optimization Tool: User's Reference Manual
NASA Technical Reports Server (NTRS)
Pak, Chan-Gi; Truong, Samson S.
2015-01-01
The National Aeronautics and Space Administration Armstrong Flight Research Center has developed a cost-effective and flexible object-oriented optimization (O (sup 3)) tool that leverages existing tools and practices and allows easy integration and adoption of new state-of-the-art software. This object-oriented framework can integrate the analysis codes for multiple disciplines, as opposed to relying on one code to perform analysis for all disciplines. Optimization can thus take place within each discipline module, or in a loop between the O (sup 3) tool and the discipline modules, or both. Six different sample mathematical problems are presented to demonstrate the performance of the O (sup 3) tool. Instructions for preparing input data for the O (sup 3) tool are detailed in this user's manual.
2017-02-16
APEX-04, or Advanced Plant EXperiments-04, is being prepared in a cold room in the Kennedy Space Center Processing Facility for SpaceX-10. The 30 petri plates are bundled into groups of 10 and placed into one of three science kits. The science kits allow easy handling when the crew removes the plates from cold stowage on station. Dr. Anna Lisa Paul of the University of Florida is the principal investigator for APEX-04. Apex-04 is an experiment involving Arabidopsis in petri plates inside the Veggie facility aboard the International Space Station. Since Arabidopsis is the genetic model of the plant world, it is a perfect sample organism for performing genetic studies in spaceflight. The experiment is the result of a grant from NASA’s Space Life and Physical Sciences division.
ERIC Educational Resources Information Center
Meyers, Judith N.
The test-preparation program in this guide covers all forms of test taking to help students deal with real-world problems like test anxiety and insufficient preparation time. The chapters are: (1) "Finding Out about the Tests You Must Take"; (2) "Making a Study Plan"; (3) "Carrying Out Your Study Plan"; (4) "Learning Strategies"; (5) "Coping with…
Tycova, Anna; Prikryl, Jan; Foret, Frantisek
2016-04-01
The use of high quality fused silica capillary nanospray tips is critical for obtaining reliable and reproducible electrospray/MS data; however, reproducible laboratory preparation of such tips is a challenging task. In this work, we report on the design and construction of low-cost grinding device assembled from 3D printed and commercially easily available components. Detailed description and characterization of the grinding device is complemented by freely accessible files in stl and skp format allowing easy laboratory replication of the device. The process of sharpening is aimed at achieving maximal symmetricity, surface smoothness and repeatability of the conus shape. Moreover, the presented grinding device brings possibility to fabricate the nanospray tips of desired dimensions regardless of the commercial availability. On several samples of biological nature (reserpine, rabbit plasma, and the mixture of three aminoacids), performance of fabricated tips is shown on CE coupled to MS analysis. The special interest is paid to the effect of tip sharpness. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Melo, Lucio F C; Collins, Carol H; Jardim, Isabel C S F
2004-04-02
Sample preparation procedures which included the use of new aminopropyl (NH2) and octadecyl (C18) solid-phase extraction (SPE) sorbents are proposed for the simultaneous multiclass determination of the fungicide benomyl and of the herbicides tebuthiuron, diuron, simazine, atrazine, and ametryn in grapes, using single wavelength high-performance liquid chromatography. Sorbent preparation uses a fast, easy, and effective procedure to obtain silica-based materials, made by depositing polysiloxanes on a silica support followed by thermal immobilization. Recovery results of the compounds, after elution from the SPE cartridges, indicate that the most efficient system employed silica loaded with 40% of an aminofunctional polydimethylsiloxane as sorbent, using dichloromethane:methanol (95:5, v/v) as eluent. Method validation, carried out in agreement with International Conference on Harmonization directives, was performed at three fortification levels (100, 200, and 1000 microg kg(-1)). Limits of detection and quantification show that the method developed can be used to detect the pesticides at concentrations below the maximum residue levels established by Codex Alimentarius, the US Environmental Protection Agency, the European Union, and Brazilian legislation.
NASA Astrophysics Data System (ADS)
R. S., Aparna; J. S., Anjali Devi; John, Nebu; Abha, K.; S. S., Syamchand; George, Sony
2018-06-01
Hurdles to develop point of care diagnostic methods restrict the translation of progress in the health care sector from bench side to bedside. In this article a simple, cost effective fluorescent as well as colorimetric nanosensor was developed for the early and easy detection of hyperbilirubinemia. A stable, water soluble bovine serum albumin stabilised copper nanocluster (BSA CuNC) was used as the fluorescent probe which exhibited strong blue emission (404 nm) upon 330 nm excitation. The fluorescence of the BSA CuNC can be effectively quenched by the addition of bilirubin by the formation of copper-bilirubin complex. Meanwhile the copper-bilirubin complex resulted in an observable colour change from pale violet to green facilitating colorimetric detection. The prepared sensor displayed good selectivity and sensitivity over other co-existing molecules, and can be used for quantifying bilirubin with a detection limit down to 257 fM. Additionally, the as-prepared probe was coated on a paper strip to develop a portable paper strip sensor of bilirubin. Moreover, the method was successfully applied in real sample analysis and obtained promising result.
Preparation of 14C-Labeled Sterigmatocystin in Liquid Media
Hsieh, Dennis P. H.; Yang, Susie L.
1975-01-01
14C-labeled sterigmatocystin was prepared from surface cultures of Aspergillus versicolor A-18074 maintained in liquid media by multiple additions of [1-14C]acetate to the cultures. The highest yield of 7.75 mg/10 ml was found with a sucrose-asparagine-ammonium medium in which more than 3% of the radioactivity of the added [1-14C]acetate was recovered in the purified [ring-14C] sterigmatocystin. The method offers an easy way to prepare 14C-labeled sterigmatocystin for studies of this mycotoxin. PMID:1110489
Zhang, Yuping; Jiang, Shimei
2012-09-14
A new and easy-to-prepare gelator based on cyano-substituted amide (BPNIA) was designed and synthesized. BPNIA could form thermoreversible gel in DMSO-H(2)O (v/v, 9 : 1) and ultrasound-stimulated gel in DMSO. FT-IR, UV-vis and XRD spectra indicated that the gelator molecules self-assemble into a fibrous network resulting from the cooperation of intermolecular hydrogen bonding, π-π stacking and cyano interactions. BPNIA can act as a highly selective colorimetric sensor for fluoride in DMSO, overcoming the interference of H(2)PO(4)(-), AcO(-) and other halide anions. The deprotonation of the NH groups is responsible for the dramatic color change from colorless to yellow. Interestingly, the organogel of BPNIA could allow a two channel fluoride response by proton controlled reversible sol-gel transition and color changes.
Xiong, Yan; Ye, Zhongbin; Xu, Jing; Zhu, Yuanqiang; Chen, Chen; Guan, Yafeng
2013-03-21
A novel integrated fiber-optic sensor with micro detection volume is developed and evaluated for O(2) determination on a breath-by-breath basis in human health monitoring applications. The sensing element was fabricated by dip-coating an uncladded optical fiber with [Ir(piq)(2)(acac)]-doped hybrid fluorinated ORMOSIL (organically modified silicate) film, which was prepared from 3,3,3-trifluoropropyltrimethoxysilane (TFP-TriMOS) and n-propyltrimethoxysilane (n-propyl-TriMOS). The sensor was then constructed by inserting the prepared optical fiber into a transparent capillary. A microchannel formed between the optical fiber and the capillary inner wall acted as a flow cell for the sample flowing through. The evanescent wave (EW) field produced on the fiber core surface can excite the O(2)-sensitive fluorophores of [Ir(piq)(2)(acac)] to produce emission fluorescence. O(2) can be sensed by its quenching effect on the emission fluorescence intensity. Spectroscopic properties have been characterized by FTIR and fluorescence measurements. Stern-Volmer and Demas models were both employed to analyse the sensor sensitivity, which is 13.0 with the LOD = 0.009% (3σ) and the response time is about 1 s. By integrating the sensing and detection elements on the optical fiber, the novel configuration showed advantages of easy fabrication and low cost. Parameters of sensitivity, response time, repeatability, humidity effect and temperature effect were discussed in detail. The proposed sensor showed potential for practical in-breath O(2) analysis application due to its advantages of easy fabrication, low cost, fast response, excellent hydrophobicity, negligible temperature interference and suitable sensitivity.
Minimizing Postsampling Degradation of Peptides by a Thermal Benchtop Tissue Stabilization Method
Segerström, Lova; Gustavsson, Jenny
2016-01-01
Enzymatic degradation is a major concern in peptide analysis. Postmortem metabolism in biological samples entails considerable risk for measurements misrepresentative of true in vivo concentrations. It is therefore vital to find reliable, reproducible, and easy-to-use procedures to inhibit enzymatic activity in fresh tissues before subjecting them to qualitative and quantitative analyses. The aim of this study was to test a benchtop thermal stabilization method to optimize measurement of endogenous opioids in brain tissue. Endogenous opioid peptides are generated from precursor proteins through multiple enzymatic steps that include conversion of one bioactive peptide to another, often with a different function. Ex vivo metabolism may, therefore, lead to erroneous functional interpretations. The efficacy of heat stabilization was systematically evaluated in a number of postmortem handling procedures. Dynorphin B (DYNB), Leu-enkephalin-Arg6 (LARG), and Met-enkephalin-Arg6-Phe7 (MEAP) were measured by radioimmunoassay in rat hypothalamus, striatum (STR), and cingulate cortex (CCX). Also, simplified extraction protocols for stabilized tissue were tested. Stabilization affected all peptide levels to varying degrees compared to those prepared by standard dissection and tissue handling procedures. Stabilization increased DYNB in hypothalamus, but not STR or CCX, whereas LARG generally decreased. MEAP increased in hypothalamus after all stabilization procedures, whereas for STR and CCX, the effect was dependent on the time point for stabilization. The efficacy of stabilization allowed samples to be left for 2 hours in room temperature (20°C) without changes in peptide levels. This study shows that conductive heat transfer is an easy-to-use and efficient procedure for the preservation of the molecular composition in biological samples. Region- and peptide-specific critical steps were identified and stabilization enabled the optimization of tissue handling and opioid peptide analysis. The result is improved diagnostic and research value of the samples with great benefits for basic research and clinical work. PMID:27007059
Testing biological liquid samples using modified m-line spectroscopy method
NASA Astrophysics Data System (ADS)
Augusciuk, Elzbieta; Rybiński, Grzegorz
2005-09-01
Non-chemical method of detection of sugar concentration in biological (animal and plant source) liquids has been investigated. Simplified set was build to show the easy way of carrying out the survey and to make easy to gather multiple measurements for error detecting and statistics. Method is suggested as easy and cheap alternative for chemical methods of measuring sugar concentration, but needing a lot effort to be made precise.
Fernandes, Virgínia C; Lehotay, Steven J; Geis-Asteggiante, Lucía; Kwon, Hyeyoung; Mol, Hans G J; van der Kamp, Henk; Mateus, Nuno; Domingues, Valentina F; Delerue-Matos, Cristina
2014-01-01
This study analysed 22 strawberry and soil samples after their collection over the course of 2 years to compare the residue profiles from organic farming with integrated pest management practices in Portugal. For sample preparation, we used the citrate-buffered version of the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. We applied three different methods for analysis: (1) 27 pesticides were targeted using LC-MS/MS; (2) 143 were targeted using low pressure GC-tandem mass spectrometry (LP-GC-MS/MS); and (3) more than 600 pesticides were screened in a targeted and untargeted approach using comprehensive, two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-TOF-MS). Comparison was made of the analyses using the different methods for the shared samples. The results were similar, thereby providing satisfactory confirmation of both similarly positive and negative findings. No pesticides were found in the organic-farmed samples. In samples from integrated pest management practices, nine pesticides were determined and confirmed to be present, ranging from 2 µg kg(-1) for fluazifop-p-butyl to 50 µg kg(-1) for fenpropathrin. Concentrations of residues in strawberries were less than European maximum residue limits.
Sodium perxenate permits rapid oxidation of manganese for easy spectrophotometric determination
NASA Technical Reports Server (NTRS)
Bane, R. W.
1967-01-01
Sodium perxenate oxidizes manganese to permanganate almost instantaneously in dilute acid solution and without a catalyst. A solution is prepared by dissolving 200 mg of sodium perxenate in distilled water and diluting to 100 ml.
Andrés-Costa, María Jesús; Andreu, Vicente; Picó, Yolanda
2016-08-26
Emerging drugs of abuse, belonging to many different chemical classes, are attracting users with promises of "legal" highs and easy access via internet. Prevalence of their consumption and abuse through wastewater-based epidemiology can only be realized if a suitable analytical screening procedure exists to detect and quantify them in water. Solid-phase extraction and ultra-high performance liquid chromatography quadrupole time-of-flight-mass spectrometry (UHPLC-QqTOF-MS/MS) was applied for rapid suspect screening as well as for the quantitative determination of 42 illicit drugs and metabolites in water. Using this platform, we were able to identify amphetamines, tryptamines, piperazines, pyrrolidinophenones, arylcyclohexylamines, cocainics, opioids and cannabinoids. Additionally, paracetamol, carbamazepine, ibersartan, valsartan, sulfamethoxazole, terbumeton, diuron, etc. (including degradation products as 3-hydroxy carbamazepine or deethylterbuthylazine) were detected. This method encompasses easy sample preparation and rapid identification of psychoactive drugs against a database that cover more than 2000 compounds that ionized in positive mode, and possibility to identify metabolites and degradation products as well as unknown compounds. The method for river water, influent and effluents samples was fully validated for the target psychoactive substances including assessment of matrix effects (-88-67.8%), recovery (42-115%), precision (<19%) and limits of quantification (1-100ngL(-1)). Method efficiency was thoroughly investigated for a wide range of waste and surface waters. Robust and repeatable functioning of this platform in the screening, identification and quantification of traditional and new psychoactive drugs biomarkers and other water contaminants is demonstrated. Copyright © 2016 Elsevier B.V. All rights reserved.
Li, Yan-Fei; Qiao, Lu-Qin; Li, Fang-Wei; Ding, Yi; Yang, Zi-Jun; Wang, Ming-Lin
2014-09-26
Based on a modified quick, easy, cheap, effective, rugged and safe (QuEChERS) sample preparation method with Fe3O4 magnetic nanoparticles (MNPs) as the adsorbing material and gas chromatography-tandem mass spectrometry (GC-MS/MS) determination in multiple reaction monitoring (MRM) mode, we established a new method for the determination of multiple pesticides in vegetables and fruits. It was determined that bare MNPs have excellent function as adsorbent when purified, and it is better to be separated from the extract. The amount of MNPs influenced the clean-up performance and recoveries. To achieve the optimum performance of modified QuEChERS towards the target analytes, several parameters including the amount of the adsorbents and purification time were investigated. Under the optimum conditions, recoveries were evaluated in four representative matrices (tomato, cucumber, orange and apple) with the spiked concentrations of 10 μg kg(-1), 50 μg kg(-1)and 200 μg kg(-1) in all cases. The results showed that the recovery of 101 pesticides ranged between 71.5 and 111.7%, and the relative standard deviation was less than 10.5%. The optimum clean-up system improved the purification efficiency and simultaneously obtained satisfactory recoveries of multiple pesticides, including planar-ring pesticides. In short, the modified QuEChERS method in addition to MNPs used for removing impurities improved the speed of sample pre-treatment and exhibited an enhanced performance and purifying effect. Copyright © 2014 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Elgin, Sarah C. R.; Flowers, Susan; May, Victoria
2005-01-01
Teaching laboratory science in a high school setting has never been easy. Time is available in short blocks; laboratory facilities are often quite limited. In most American high schools, teachers are responsible not only for preparation of their lesson plans, but also for ordering and preparing any materials to be used in a lab, with little or no…
ERIC Educational Resources Information Center
Green, Jeffrey M.
2012-01-01
Our nation's public schools have been given the task of preparing our students for success in college as well as future careers. Determining how to best prepare future teachers is not an easy task, and the current state of public education has had an impact on what it takes to be a successful teacher. Involving pre-service career and…
Plummer, Christopher M; Breadon, Thomas W; Pearson, James R; Jones, Oliver A H
2016-05-01
This work examines the chemical synthesis of 3,4-methylenedioxy-N-methylamphetamine (MDMA) from piperonal prepared via a catalytic ruthenium tetroxide oxidation of piperine extracted from black pepper. A variety of oxidation conditions were experimented with including different solvent systems and co-oxidants. A sample of prepared piperonal was successfully converted into MDMA via 3,4-methylenedioxyphenyl-2-nitropropene (MDP2NP) and 3,4-methylenedioxyphenyl-2-propanone (MDP2P) and the impurities within each product characterised by GC-MS to give a contaminant profile of the synthetic pathway. Interestingly, it was discovered that a chlorinated analogue of piperonal (6-chloropiperonal) was created during the oxidation process by an as yet unknown mechanism. This impurity reacted alongside piperonal to give chlorinated analogues of each precursor, ultimately yielding 2-chloro-4,5-methylenedioxymethamphetamine (6-Cl-MDMA) as an impurity within the MDMA sample. The methodology developed is a simple way to synthesise a substantial amount of precursor material with easy to obtain reagents. The results also show that chlorinated MDMA analogues, previously thought to be deliberately included adulterants, may in fact be route specific impurities with potential application in determining the origin and synthesis method of seized illicit drugs. Copyright © 2016 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.
[Investigation of the recrystallization of trehalose as a good glass-former excipient].
Katona, Gábor; Orsolya, Jójártné Laczkovich; Szabóné, Révész Piroska
2014-01-01
An amorphous form of trehalose is easy to prepare by using a solvent method. The recrystallization kinetics can be followed well, which is important because of the occurrence of polymorphic forms of trehalose. This is especially significant in the case of dry powder inhalers. Spray-drying was used as a preparation method this being one of the most efficient technologies with which to obtain an amorphous form. This method can result in the required particle size and a monodisperse distribution with excellent flowability and with moreover considerable amorphization. In our work, trehalose was applied as a technological auxiliary agent, and literature data relating to the spray-drying technology of trehalose were collected. Studies were made of the influence of the spraying process on the amorphization of trehalose and on the recrystallization of amorphous trehalose during storage. Amorphous samples were investigated under 3 different conditions during 3 months. The recrystallization process was followed by differential scanning calorimetry and X-ray powder diffraction. The results demonstrated the perfect amorphization of trehalose during the spray-drying process. The glass transition temperature was well measurable in the samples and proved to be the same as the literature data. Recrystallization under normal conditions was very slow but at high relative humidity the process was accelerated greatly. Amorphous trehalose gave rise to dihydrate forms (gamma- and h-trehaloses) during recrystallization, and beta-trehalose was also identified as an anhydrous form.
Ito, Ikumi; Ito, Akihiko; Unezaki, Sakae
2017-01-01
We investigated the preparation of a gelling tablet that swells and forms a gel upon absorbing water, and hence would be easy for patients to swallow. We prepared naked tablets and compressed coated tablets by the direct tableting or wet granule-compression methods, using the commonly prescribed drug acetaminophen (AA) and sodium alginate (AG) as a thickening agent. The tablets quickly absorbed water, had favorable gelling properties, low adhesiveness, appropriate drug dissolution profile, and at the same time, were easy to swallow. In the case of naked tablets, water absorption increased upon granulation, but gelling of AG interfere when AA and AG were present together. There was no change in the adhesiveness, and more than 30 min were required to achieve a 25% dissolution ratio. Compressed coated tablets that were made with AA in the inner layer and granulated AG in the outer layer showed improved dissolution behavior, it was about 90% dissolution ratio in 30 min, owing to the water absorption property of AG, and decreased adhesiveness. In this case, there was a difference in the outer layer thickness. As the outer layer amount increased, dissolution slowed, but it did not depend on the compression pressure. Our gelling tablet can be prepared by using AA (main drug) in the inner layer and an appropriate thickness of granulated AG in the outer layer of compressed coated tablets.
Eom, Taeyong; Cho, Hyun-Deok; Kim, Junghyun; Park, Mihee; An, Jinyoung; Kim, Moosung; Kim, Sheen-Hee; Han, Sang Beom
2017-11-01
A simple and rapid method for the simultaneous determination of 11 mycotoxins - aflatoxins B 1 , B 2 , G 1 and G 2 ; fumonisins B 1 , B 2 and B 3 ; ochratoxin A; zearalenone; deoxynivalenol; and T-2 toxin - in edible oils was established using liquid chromatography tandem mass spectrometry (LC-MS/MS). In this study, QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe), QuEChERS with dispersive liquid-liquid microextraction, and solvent extraction were examined for sample preparation. Among these methods, solvent extraction with a mixture of formic acid/acetonitrile (5/95, v/v) successfully extracted all target mycotoxins. Subsequently, a defatting process using n-hexane was employed to remove the fats present in the edible oil samples. Mass spectrometry was carried out using electrospray ionisation in polarity switching mode with multiple reaction monitoring. The developed LC-MS/MS method was validated by assessing the specificity, linearity, recovery, limit of quantification (LOQ), accuracy and precision with reference to Commission Regulation (EC) 401/2006. Mycotoxin recoveries of 51.6-82.8% were achieved in addition to LOQs ranging from 0.025 ng/g to 1 ng/g. The edible oils proved to be relatively uncomplicated matrices and the developed method was applied to 9 edible oil samples, including soybean oil, corn oil and rice bran oil, to evaluate potential mycotoxin contamination. The levels of detection were significantly lower than the international regulatory standards. Therefore, we expect that our developed method, based on simple, two-step sample preparation process, will be suitable for the large-scale screening of mycotoxin contamination in edible oils.
Smith, Joshua T.; Kennedy, Theodore A.; Muehlbauer, Jeffrey D.
2014-01-01
Insect emergence is a fundamental process in freshwaters. It is a critical life-history stage for aquatic insects and provides an important prey resource for terrestrial and aquatic consumers. Sticky traps are increasingly being used to sample these insects. The most common design consists of an acetate sheet coated with a nondrying adhesive that is attached to a wire frame or cylinder. These traps must be prepared at the deployment site, a process that can be time consuming and difficult given the vagaries of field conditions. Our goals were to develop a sturdy, low-cost sticky trap that could be prepared in advance, rapidly deployed and recovered in the field, and used to estimate the flight direction of insects. We used 150-mm Petri dishes with lids. The dishes can be coated cleanly and consistently with Tangle-Trap® adhesive. Deploying traps is simple and requires only a pole set near the body of water being sampled. Four dishes can be attached to the pole using Velcro and aligned in 4 different directions to enable quantification of insect flight direction. After sampling, Petri dishes can be taped closed, packed in boxes, and stored indefinitely. Petri traps are comparable in price to standard acetate sheet traps at ∼US$0.50/directional deployment, but they require more space for storage than acetate sheet traps. However, a major benefit of Petri traps is that field deployment times are ⅓ those of acetate traps. Our study demonstrated that large Petri dishes are an ideal platform for sampling postemergent adult aquatic insects, particularly when the study design involves estimating flight direction and when rapid deployment and recovery of traps is critical.
NASA Technical Reports Server (NTRS)
1978-01-01
The woman pictured below is sitting down to a nutritious, easily-prepared meal similar to those consumed by Apollo astronauts. The appetizing dishes shown were created simply by adding water to the contents of a Mountain House* Easy Meal package of freeze dried food. The Easy Meal line is produced by Oregon Freeze Dry Foods, Inc., Albany, Oreaon, a pioneer in freeze drying technology and a company long associated with NASA in developing suitable preparations for use on manned spacecraft. Designed to provide nutritionally balanced, attractive hot meals for senior adults, Easy Meal is an offshoot of a 1975-77 demonstration project managed by Johnson Space Center and called Meal System for the Elderly. The project sought ways to help the estimated 3.5 million elderly Americans who are unable to take advantage of existing meal programs. Such services are provided by federal, state and local agencies, but they are not available to many who live in rural areas, or others who are handicapped, temporarily ill or homebound for other reasons. Oregon Freeze Dry Foods was a participant in that multi-agency cooperative project. With its Easy Meal assortment of convenience foods pictured above left, the company is making commercially available meal packages similar to those distributed in the Meal System for the Elderly program. In the freeze drying process, water is extracted from freshly-cooked foods by dehydration at very low temperatures, as low as 50 I degrees below zero. Flavor is locked in by packaging the dried food in pouches which block out moisture and oxygen, the principal causes of food deterioration; thus the food can be stored for long periods without refrigeration. Meals are reconstituted by adding hot or cold water, depending on the type of food, and they are table ready in five to 10 minutes. Oregon Freeze Dry Foods offers five different meal packages and plans to expand the line.
Jia, Jing; Xu, Lili; Wang, Shuai; Wang, Licheng; Liu, Xia
2014-05-01
Nanotubular titania film was prepared in situ on titanium wire and was used as the fiber substrate for solid-phase microextraction (SPME) because of its high surface-to-volume ratio, easy preparation, and mechanical stability. Three different functional coatings, β-cyclodextrin (β-CD), β-cyclodextrin-co-poly(ethylenepropylene glycol) (β-CD/PEG), and polyethylene glycol (PEG)-based sorbents were chemically bonded to the nanostructured wire surface via sol-gel technology to further enhance the absorbing capability and extraction selectivity. Coupled to gas chromatography-flame ionic detection (GC-FID), the prepared SPME fibers were investigated using diverse compounds. The results indicated that the fibers showed good mechanical strength, excellent thermal stability, and wonderful capacity and selectivity to polar compounds, including polar aromatic compounds, alcohols, and ketones. Combining the superior hydrophilic property of a bonded functional molecule and the highly porous structure of a fiber coating, the prepared PEG-coated SPME fiber showed much higher adsorption affinity to ephedrine and methylephedrine than β-CD and β-CD/PEG fibers. The as-established PEG-coated SPME-GC analytical method provided excellent sensitivity (LODs, 0.004 and 0.001 ng mL(-1) for ephedrine and methylephedrine, respectively) and better linear range (0.01-2 000 μg L(-1)). In addition, it has surprising repeatability and reproducibility. Finally, the present approach was used to analyze ephedrine and methylephedrine from real urine samples, and reliable results were obtained.
NASA - easyJet Collaboration on the Human Factors Monitoring Program (HFMP) Study
NASA Technical Reports Server (NTRS)
Srivistava, Ashok N.; Barton, Phil
2012-01-01
This is the first annual report jointly prepared by NASA and easyJet on the work performed under the agreement to collaborate on a study of the many factors entailed in flight - and cabin-crew fatigue and documenting the decreases in performance associated with fatigue. The objective of this Agreement is to generate reliable, automated procedures that improve understanding of the levels and characteristics of flight - and cabin-crew fatigue factors, both latent and proximate, whose confluence will likely result in unacceptable flight crew performance. This study entails the analyses of numerical and textual data collected during operational flights. NASA and easyJet are both interested in assessing and testing NASA s automated capabilities for extracting operationally significant information from very large, diverse (textual and numerical) databases, much larger than can be handled practically by human experts.
NASA Technical Reports Server (NTRS)
Srivistava, Ashok N.; Barton, Phil
2012-01-01
This is the second interim report jointly prepared by NASA and easyJet on the work performed under the agreement to collaborate on a study of the factors entailed in flight and cabin-crew fatigue, and decreases in performance associated with fatigue. The objective of this Agreement is to generate reliable procedures that aid in understanding the levels and characteristics of flight and cabin-crew fatigue factors, both latent and proximate, whose confluence will likely result in unacceptable crew performance. This study entails the analyses of numerical and textual data collected during operational flights. NASA and easyJet are both interested in assessing and testing NASA s automated capabilities for extracting operationally significant information from very large, diverse (textual and numerical) databases; much larger than can be handled practically by human experts.
A Decentralized IT Architecture for Locating and Negotiating Access to Biobank Samples.
Proynova, Rumyana; Alexandre, Diogo; Lablans, Martin; Van Enckevort, David; Mate, Sebastian; Eklund, Niina; Silander, Kaisa; Hummel, Michael; Holub, Petr; Ückert, Frank
2017-01-01
There is a need among researchers for the easy discoverability of biobank samples. Currently, there is no uniform way for finding samples and negotiate access. Instead, researchers have to communicate with each biobank separately. We present the architecture for the BBMRI-CS IT platform, whose goal is to facilitate sample location and access. We chose a decentral approach, which allows for strong data protection and provides the high flexibility needed in the highly heterogeneous landscape of European biobanks. This is the first implementation of a decentral search in the biobank field. With the addition of a Negotiator component, it also allows for easy communication and a follow-through of the lengthy approval process for accessing samples.
New radiocarbon measurement methods in the Hertelendi Laboratory, Hungary
NASA Astrophysics Data System (ADS)
Janovics, Róbert; Major, István; Rinyu, László; Veres, Mihály; Molnár, Mihály
2013-04-01
In this paper we present two very different and novel methods for C-14 measurement from dissolved inorganic carbonate (DIC) of water samples. A new LSC sample preparation method for liquid scintillation C-14 measurements was implemented in the ATOMKI. The first method uses direct absorption into a special absorbent (Carbosorb E®) and a following liquid scintillation measurement. Typical sample size is 20-40 litre of water. The developed CO2 absorption method is fast, and simple. The C-14 activities is measured by an ultra low background LSC (TRI-CARB 3170 TR/SL, Perkin Elmer) including quenching parameter (tSIE).The corresponding limit of C-14 dating is 31200 year. Several tests were executed with old borehole CO2 gas without significant content of C-14 and also performed on samples of known C-14 activities between 29 and 7000 pMC, previously measured by GPC. The combined uncertainty of the described determination is about 2 % in the case of recent carbon. It is a very cost-effective and easy to use method based on a novel and simple static absorption process for the CO2 extracted from groundwater. The other very sensitive method is based on accelerator mass spectrometry (AMS) using gas ion source. This method does not require graphite generation and a small volume of water sample (1-20mL) is enough for the radiocarbon measurement. The procedure is very similar to pre-treatment of carbonate contained sample preparation for stable isotope measurement with gasbench technique. We applied a MICADAS type accelerator mass spectrometry (AMS) with gas ion source for C-14 analysis. The radiocarbon content of water was sat free with phosphoric acid and then the headspace gas was rinsed vials. The whole measurement needs only 20 min of each sample. The precision of measurement is better than 1% for modern samples. The preparation is vastly reduced compared to the other AMS methods and principally allows fully automated measurements of groundwater samples with an auto-sampler. The presented two new methods can be suitable for C-14 measurements and dating of hydrological, and environmental samples as well. The new AMS facility in ATOMKI (Debrecen, Hungary) using an EnvironMICADAS AMS system with gas ion source has a great potential in groundwater C-14 analyses. The research was supported by the by TÁMOP-4.2.2.A-11/1/KONV and the Hungarian NSF (OTKA MB08-A 81515)
Recent progress in preparation and application of microfluidic chip electrophoresis
NASA Astrophysics Data System (ADS)
Cong, Hailin; Xu, Xiaodan; Yu, Bing; Yuan, Hua; Peng, Qiaohong; Tian, Chao
2015-05-01
Since its discovery in 1990, microfluidic chip electrophoresis (MCE) has allowed the development of applications with small size, fast analysis, low cost, high integration density and automatic level, which are easy to carry and have made commercialization efficient. MCE has been widely used in the areas of environmental protection, biochemistry, medicine and health, clinical testing, judicial expertise, food sanitation, pharmaceutical checking, drug testing, agrochemistry, biomedical engineering and life science. As one of the foremost fields in the research of capillary electrophoresis, MCE is the ultimate frontier to develop the miniaturized, integrated, automated all-in-one instruments needed in modern analytical chemistry. By adopting the advanced technologies of micro-machining, lasers and microelectronics, and the latest research achievements in analytical chemistry and biochemistry, the sampling, separation and detection systems of commonly used capillary electrophoresis are integrated with high densities onto glass, quartz, silicon or polymer wafers to form the MCE, which can finish the analysis of multi-step operations such as injection, enrichment, reaction, derivatization, separation, and collection of samples in a portable, efficient and super high speed manner. With reference to the different technological achievements in this area, the latest developments in MCE are reviewed in this article. The preparation mechanisms, surface modifications, and properties of different materials in MCE are compared, and the different sampling, separation and detection systems in MCE are summarized. The performance of MCE in analysis of fluorescent substance, metallic ion, sugar, medicine, nucleic acid, DNA, amino acid, polypeptide and protein is discussed, and the future direction of development is forecast.
NASA Taxonomy 2.0 Project Overview
NASA Technical Reports Server (NTRS)
Dutra, Jayne; Busch, Joseph
2004-01-01
This viewgraph presentation reviews the project to develop a Taxonomy for NASA. The benefits of this project are: Make it easy for various audiences to find relevant information from NASA programs quickly, specifically (1) Provide easy access for NASA Web resources (2) Information integration for unified queries and management reporting ve search results targeted to user interests the ability to move content through the enterprise to where it is needed most (3) Facilitate Records Management and Retention Requirements. In addition the project will assist NASA in complying with E-Government Act of 2002 and prepare NASA to participate in federal projects.
Rapid and reliable determination of the halogenating peroxidase activity in blood samples.
Flemmig, Jörg; Schwarz, Pauline; Bäcker, Ingo; Leichsenring, Anna; Lange, Franziska; Arnhold, Jürgen
2014-12-15
By combining easy and fast leukocyte enrichment with aminophenyl-fluorescein (APF) staining we developed a method to quickly and specifically address the halogenating activity of the immunological relevant blood heme peroxidases myeloperoxidase and eosinophil peroxidase, respectively. For leukocyte enrichment a two-fold hypotonic lysis procedure of the blood with Millipore water was chosen which represents a cheap, fast and reliable method to diminish the amount of erythrocytes in the samples. This procedure is shown to be suitable both to human and murine blood micro-samples, making it also applicable to small animal experiments with recurring blood sampling. As all types of leukocytes are kept in the sample during the preparation, they can be analysed separately after discrimination during the flow cytometry analysis. This also holds for all heme peroxidase-containing cells, namely neutrophils, eosinophils and monocytes. Moreover additional parameters (e.g. antibody staining) can be combined with the heme peroxidase activity determination to gain additional information about the different immune cell types. Based on previous results we applied APF for specifically addressing the halogenating activity of leukocyte peroxidases in blood samples. This dye is selectively oxidized by the MPO and EPO halogenation products hypochlorous and hypobromous acid. This approach may provide a suitable tool to gain more insights into the immune-physiological role of the halogenating activity of heme peroxidases. Copyright © 2014 Elsevier B.V. All rights reserved.
Lerman, Imanuel R; Souzdalnitski, Dmitri; Narouze, Samer
2012-01-01
This technical report describes a durable, low-cost, anatomically accurate, and easy-to-prepare combined ultrasound (US) and fluoroscopic phantom of the cervical spine. This phantom is meant to augment training in US- and fluoroscopic-guided pain medicine procedures. The combined US and fluoroscopic phantom (CUF-P) is prepared from commercially available liquid plastic that is ordinarily used to prepare synthetic fishing lures. The liquid plastic is heated and then poured into a metal canister that houses an anatomical cervical spine model. Drops of dark purple dye are added to make the phantom opaque. After cooling, tubing is attached to the CUF-P to simulate blood vessels. The CUF-P accurately simulates human tissue by imitating both the tactile texture of skin and the haptic resistance of human tissue as the needle is advanced. This phantom contains simulated fluid-filled vertebral arteries that exhibit pulsed flow under color Doppler US. Under fluoroscopic examination, the CUF-P-simulated vertebral arteries also exhibit uptake of contrast dye if mistakenly injected. The creation of a training phantom allows the pain physician to practice needle positioning technique while simultaneously visualizing both targeted and avoidable vascular structures under US and fluoroscopic guidance. This low-cost CUF-P is easy to prepare and is reusable, making it an attractive alternative to current homemade and commercially available phantom simulators.
Maleki, Ali; Movahed, Hamed; Ravaghi, Parisa
2017-01-20
In this work, design, preparation and performance of magnetic cellulose/Ag nanobiocomposite as a recyclable and highly efficient heterogeneous nanocatalyst is described. Fourier transform infrared (FT-IR) spectroscopy, X-ray diffraction (XRD) pattern, vibrating sample magnetometer (VSM) curve, field-emission scanning electron microscopy (FE-SEM) image, energy dispersive X-ray (EDX) analysis and thermogravimetric analysis/differential thermal analysis (TGA/DTA) were used for the characterization. Then, its activity was investigated in the synthesis of 2-amino-6-(2-oxo-2H-chromen-3-yl)-4-phenylnicotinonitrile derivatives. The main advantages of the reaction are high yields and short reaction times. The remarkable magnetic property of the nanobiocomposite catalyst provides easy separation from the reaction mixture by an external magnet without considerable loss of its catalytic activity. Copyright © 2016 Elsevier Ltd. All rights reserved.
Enhancement of hydrogen gas permeability in electrically aligned MWCNT-PMMA composite membranes.
Kumar, Sumit; Sharma, Anshu; Tripathi, Balram; Srivastava, Subodh; Agrawal, Shweta; Singh, M; Awasthi, Kamlendra; Vijay, Y K
2010-10-01
The multi-walled carbon nanotube (MWCNT) dispersed polymethylmethacrylate (PMMA) composite membranes have been prepared for hydrogen gas permeation application. Composite membranes are characterized by Raman spectroscopy, optical microscopy, X-ray diffraction, electrical measurements and gas permeability measurements. The effect of electric field alignment of MWCNT in PMMA matrix on gas permeation has been studied for hydrogen gas. The permeability measurements indicated that the electrically aligned MWCNT in PMMA has shown almost 2 times higher permeability for hydrogen gas as compare to randomly dispersed MWCNT in PMMA. The enhancement in permeability is explained on the basis of well aligned easy channel provided by MWCNT in electrically aligned sample. The effect of thickness of membrane on the gas permeability also studied and thickness of about 30microm found to be optimum thickness for fast hydrogen gas permeates.
Instructional Principles for Online Learning
ERIC Educational Resources Information Center
Chang, Shujen L.
2004-01-01
Four instructional principles for alleviating cognitive overload in online learning are suggested: 1) Guide learners to prepare and maintain an effective workstation for accessing online materials, 2) Employ advance organizers for effective online navigation, 3) Arrange instructional materials for easy online manipulation, and 4) Organize…
Fontana, Ariel R; Bottini, Rubén
2014-05-16
In this work, a reliable, simple, fast, inexpensive and robust sample preparation approach for the determination of multiclass polyphenols in wine samples is proposed. The polyphenols selected for this work were gallic acid, (+)-catechin, (-)-epicatechin, caffeic acid, syringic acid, coumaric acid, ferulic acid, trans-resveratrol, quercetin and cinnamic acid. The method is based on QuEChERS (quick, easy, cheap, effective, rugged and safe) extraction technique coupled with dispersive solid-phase extraction (d-SPE) clean-up. Under optimized conditions, the analytes were extracted from 5mL wine samples (previously acidified with 1% formic acid) using 2.5mL acetonitrile. For phase separation, 1.5g NaCl and 4g anhydrous MgSO4 were added. Then, a 1mL aliquot of the partitioned supernatant was cleaned-up using d-SPE with a combination of 150mg CaCl2, 50mg primary-secondary amine (PSA) and 50mgC18 as sorbents. A 250μL aliquot of the obtained cleaned extract was concentrated to dryness and taken up with the initial mobile phase previous to liquid chromatography-multi-wavelength detection (LC-MWD). The proposed method provided limits of detection (LODs) ranging from 0.004 to 0.079μgmL(-1) and an inter-day variability below 12% RSD for all analytes in red and white wine samples. Considering external calibration (red wines) and matrix-matched calibration (white wines) as quantification techniques, the overall recoveries (accuracy) of the method ranged between 75.0% and 119.6% for red and white wine samples, respectively. The developed method was applied for the determination of polyphenols in 10 wines produced in Argentina. Nine phenolic compounds were determined, at concentrations above detectable levels in the method. The maximum concentrations corresponded to (-)-epicatechin in white wines, while gallic acid and (+)-catechin were the most abundant in red wines. Copyright © 2014 Elsevier B.V. All rights reserved.
Hickert, Sebastian; Bergmann, Marian; Ersen, Seyma; Cramer, Benedikt; Humpf, Hans-Ulrich
2016-02-01
A HPLC-MS/MS-based method for the quantification of nine mycotoxins produced by fungi of the genus Alternaria in various food matrices was developed. The method relies on a single-step extraction, followed by dilution of the raw extract and direct analysis. In combination with an analysis time per sample of 12 min, the sample preparation is cost-effective and easy to handle. The method covers alternariol (AOH), alternariol monomethyl ether (AME), tenuazonic acid (TeA), altenuene (ALT), iso-altenuene (isoALT), tentoxin (TEN), altertoxin-I (ATX-I), and the AAL toxins TA1 and TA2. Some Alternaria toxins which are either not commercially available or very expensive, namely AOH, AME, ALT, isoALT, and ATX-I, were isolated as reference compounds from fungal cultures. The method was extensively validated for tomato products, bakery products, sunflower seeds, fruit juices, and vegetable oils. AOH, AME, TeA, and TEN were found in quantifiable amounts and 92.1% of all analyzed samples (n = 96) showed low level contamination with one or more Alternaria toxins. Based on the obtained results, the average daily exposure to Alternaria toxins in Germany was calculated.
Design and development of novel sensors for the determination of fluoride in water.
Pillai, Aji Balan; Varghese, Benjamin; Madhusoodanan, Kottarathil Naduvil
2012-01-03
The presence of high fluoride content in drinking water is a serious health hazard as it may lead to fluorosis, a serious bone disease. Taking into account of the importance of fluoride an attempt has been made to design and develop simple, low cost, and easy to use sensors for the in situ determination of fluoride in water. Two novel absorption sensors have been fabricated and their characterization done. The first one is a light emitting diode based sensor and the other one is an evanescent wave fiber optic sensor. Reagents prepared using standard methods are mixed with water sample containing fluoride ion, and the peak absorption wavelength is found out. Suitable light sources and photo detectors have been selected, and the sensors are designed to give accurate results over a wide range. A microcontroller based setup has been fabricated for recording the concentration of the measured sample in parts per billion. Both sensors have been used to analyze water samples collected from various sources and regions. The results obtained have been compared with those obtained by using a spectrophotometer used for fluoride measurement and found to have one to one correspondence.
Kawaguchi, Migaku; Takatsu, Akiko
2009-08-01
A candidate reference measurement procedure involving isotope dilution coupled with gas chromatography-mass spectrometry (GC-MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(2), was added to a serum sample. After equilibration, solid-phase extractions (SPE) for sample preparation and derivatization with heptafluorobutyric anhydride (HFBA) were performed for GC-MS analysis. The limit of detection (LOD) and the limit of quantification (LOQ) were 5 and 20 ng g(-1), respectively. The recovery of the added cortisol ranged from 99.8 to 101.0%. Excellent precision was obtained with a within-day variation (RSD) of 0.7% for GC-MS analysis. The accuracy of the measurement was evaluated by comparing of results of this reference measurement procedure on lyophilized human serum reference materials for cortisol (European Reference Materials (ERM)-DA 192) as Certified Reference Materials (CRMs). The results of this method for total cortisol agreed with the certified values within some uncertainty. This method, which demonstrates simply, easy, good accuracy, high precision, and is free from interferences from structural analogues, qualifies as a reference measurement procedure.
Jung, Chan-Kwon; Lee, Ahwon; Jung, Eun-Sun; Choi, Yeong-Jin; Jung, So-Lyung; Lee, Kyo-Young
2008-01-01
To compare the efficacy of the SurePath (SP) vs. conventional smears (CS) in fine needle aspiration (FNA) of thyroid gland lesions. A total of 193 FNA cases with thyroid nodules were studied. Samples from ultrasound-guided FNA were split to prepare CS and SP slides. The diagnostic categories of unsatisfactory, benign, atypical and malignant were compared. Galectin-3 immunostaining was performed on SP slides. Some differences were found between the cytomorphology of CS and SP. SP slides showed more increased cellularity and more clustered tissue fragments. On SP slides, nuclear detail and nucleoli were more easily detected and nuclear irregularity was very useful for the diagnosis of papillary carcinoma. SP showed a trend toward a lower proportion of atypical category. The overall sensitivity of FNA in diagnosing thyroid neoplasm was 90.9% for CS and 93.9% for SP. Most lesions (73%) diagnosed as papillary carcinoma after surgery showed positive staining of galectin-3. The SP method showed easy evaluation of cytomorphologic features and consistent specimen quality and appeared to be more useful in diagnosing the suspicious cases. Moreover, it offered the possibility of adjunctive immunocytochemistry on the same sample.
[Near-infrared reflectance spectroscopy predicts protein, moisture and ash in beans].
Gao, Huiyu; Wang, Guodong; Men, Jianhua; Wang, Zhu
2017-05-01
To explore the potential of near-infrared reflectance( NIR)spectroscopy to determine macronutrient contents in beans. NIR spectra and analytical measurements of protein, moisture and ash were collected from 70 kinds of beans. Reference methods were used to analyze all the ground beans samples. NIR spectra on intact and ground beans samples were registered. Partial least-squares( PLS)regression models were developed with principal components analysis( PCA) to assign 49 bean accessions to a calibration data set and 21 accessions to an external validation set. For intact beans, the relative predictive determinant( RPD) values for protein and ash( 3. 67 and 3. 97, respectively) were good for screening. RPD value for moisture was only 1. 39, which was not recommended. For ground beans, the RPD values for protein, moisture and ash( 6. 63, 5. 25 and 3. 57, respectively) were good enough for screening. The protein, moisture and ash levels for intact and ground beans were all significantly correlated( P < 0. 001) between the NIR and reference method and there was no statistically significant difference in the mean with these three traits. This research demonstrates that NIR is a promising technique for simultaneous sorting ofmultiple traits in beans with no or easy sample preparation.
Xu, Xiaoli; Zhang, Song; Chen, Hui; Kong, Jilie
2009-11-15
Micro-total analysis systems (microTAS) integrate different analytical operations like sample preparation, separation and detection into a single microfabricated device. With the outstanding advantages of low cost, satisfactory analytical efficiency and flexibility in design, highly integrated and miniaturized devices from the concept of microTAS have gained widespread applications, especially in biochemical assays. Electrochemistry is shown to be quite compatible with microanalytical systems for biochemical assays, because of its attractive merits such as simplicity, rapidity, high sensitivity, reduced power consumption, and sample/reagent economy. This review presents recent developments in the integration of electrochemistry in microdevices for biochemical assays. Ingenious microelectrode design and fabrication methods, and versatility of electrochemical techniques are involved. Practical applications of such integrated microsystem in biochemical assays are focused on in situ analysis, point-of-care testing and portable devices. Electrochemical techniques are apparently suited to microsystems, since easy microfabrication of electrochemical elements and a high degree of integration with multi-analytical functions can be achieved at low cost. Such integrated microsystems will play an increasingly important role for analysis of small volume biochemical samples. Work is in progress toward new microdevice design and applications.
Investigating obesity risk-reduction behaviours and psychosocial factors in Chinese Americans.
Liou, Doreen; Bauer, Kathleen; Bai, Yeon
2014-11-01
The purpose of this research was to examine the attitudes, beliefs and behaviours related to obesity risk reduction in Chinese Americans. A questionnaire was administered to a convenience sample of 300 US-born and foreign-born Chinese Americans residing in the New York metropolitan area, ranging from 18 to 40 years of age. Obesity risk reduction behaviours and psychosocial variables derived from the Theory of Planned Behaviour and Health Belief Model were measured. Acculturation was assessed using a modified Suinn-Lew Asian Self-Identity Acculturation Scale. Frequency distributions were delineated and stepwise regression analyses were analysed for different acculturation groups. 65% of the respondents were female and the mean age of the sample was 26 years. Respondents indicated the most commonly practised behaviour to be eating home-cooked meals instead of restaurant-prepared foods. Perceived barriers to adopting obesity risk-reduction behaviours included convenience of consuming fast foods, cost, lack of time to prepare home-cooked meals, and the physical environment of unhealthy foods. In predicting intention to perform obesity risk-reduction behaviours, attitude was significant for 'western-identified' individuals. In 'Asian-identified' individuals, perceived behavioural control, self-efficacy and perceived benefits were salient. Nutrition educators working with Chinese Americans need to address self-efficacy in preparing plant-based, home-cooked meals and making healthy choices at fast-food restaurants with portion control. Concrete and perceived barriers such as lack of time and convenience need to be addressed in nutrition education interventions. Educators need to identify new channels and media outlets to disseminate practical, easy-to-implement behaviours for obesity risk reduction that are socially acceptable. © Royal Society for Public Health 2013.
Stachowicz, Aneta; Siudut, Jakub; Suski, Maciej; Olszanecki, Rafał; Korbut, Ryszard; Undas, Anetta; Wiśniewski, Jacek R
2017-01-01
It is well known that fibrin network binds a large variety of proteins, including inhibitors and activators of fibrinolysis, which may affect clot properties, such as stability and susceptibility to fibrinolysis. Specific plasma clot composition differs between individuals and may change in disease states. However, the plasma clot proteome has not yet been in-depth analyzed, mainly due to technical difficulty related to the presence of a highly abundant protein-fibrinogen and fibrin that forms a plasma clot. The aim of our study was to optimize quantitative proteomic analysis of fibrin clots prepared ex vivo from citrated plasma of the peripheral blood drawn from patients with prior venous thromboembolism (VTE). We used a multiple enzyme digestion filter aided sample preparation, a multienzyme digestion (MED) FASP method combined with LC-MS/MS analysis performed on a Proxeon Easy-nLC System coupled to the Q Exactive HF mass spectrometer. We also evaluated the impact of peptide fractionation with pipet-tip strong anion exchange (SAX) method on the obtained results. Our proteomic approach revealed 476 proteins repeatedly identified in the plasma fibrin clots from patients with VTE including extracellular vesicle-derived proteins, lipoproteins, fibrinolysis inhibitors, and proteins involved in immune responses. The MED FASP method using three different enzymes: LysC, trypsin and chymotrypsin increased the number of identified peptides and proteins and their sequence coverage as compared to a single step digestion. Peptide fractionation with a pipet-tip strong anion exchange (SAX) protocol increased the depth of proteomic analyses, but also extended the time needed for sample analysis with LC-MS/MS. The MED FASP method combined with a label-free quantification is an excellent proteomic approach for the analysis of fibrin clots prepared ex vivo from citrated plasma of patients with prior VTE.
Dietary Pattern Trajectories from 6 to 12 Months of Age in a Multi-Ethnic Asian Cohort
Lim, Geraldine Huini; Toh, Jia Ying; Aris, Izzuddin M.; Chia, Ai-Ru; Han, Wee Meng; Saw, Seang Mei; Godfrey, Keith M.; Gluckman, Peter D.; Chong, Yap-Seng; Yap, Fabian; Lee, Yung Seng; Kramer, Michael S.; Chong, Mary Foong-Fong
2016-01-01
Little is known about the dietary patterns of Asian infants in the first year of life, nor of their associations with maternal socio-demographic factors. Based on the Growing Up in Singapore towards healthy Outcomes (GUSTO) mother-offspring cohort, cross-sectional dietary patterns were derived by factor analysis using 24-h recalls and food diaries of infants at 6-, 9- and 12-months of age. Dietary pattern trajectories were modeled by mapping similar dietary patterns across each age using multilevel mixed models. Associations with maternal socio-demographic variables, collected through questionnaires during pregnancy, were assessed using general linear models. In n = 486 infants, four dietary pattern trajectories were established from 6- to 12-months. Predominantly breastmilk: mainly breastmilk and less formula milk, Guidelines: rice porridge, vegetables, fruits and low-fat fish and meat, Easy-to-prepare foods: infant cereals, juices, cakes and biscuits and Noodles (in soup) and seafood: noodle and common accompaniments. In adjusted models, higher maternal education attainment was correlated with higher start scores on Predominantly breastmilk, but lowest education attainment increased its adherence over time. Older mothers had higher start scores on Easy-to-prepare foods, but younger mothers had increased adherence over time. Chinese mothers had higher start scores on Predominantly breastmilk but greater adherence to Guidelines over time, while Indian mothers had higher start scores on Easy-to-prepare foods but greater adherence to Predominantly breastmilk with time (p < 0.05 for all). Changes in trajectories over time were small. Hence, dietary patterns established during weaning are strongly influenced by maternal socio-demographic factors and remain stable over the first year of life. PMID:27314387
Dietary Pattern Trajectories from 6 to 12 Months of Age in a Multi-Ethnic Asian Cohort.
Lim, Geraldine Huini; Toh, Jia Ying; Aris, Izzuddin M; Chia, Ai-Ru; Han, Wee Meng; Saw, Seang Mei; Godfrey, Keith M; Gluckman, Peter D; Chong, Yap-Seng; Yap, Fabian; Lee, Yung Seng; Kramer, Michael S; Chong, Mary Foong-Fong
2016-06-15
Little is known about the dietary patterns of Asian infants in the first year of life, nor of their associations with maternal socio-demographic factors. Based on the Growing Up in Singapore towards healthy Outcomes (GUSTO) mother-offspring cohort, cross-sectional dietary patterns were derived by factor analysis using 24-h recalls and food diaries of infants at 6-, 9- and 12-months of age. Dietary pattern trajectories were modeled by mapping similar dietary patterns across each age using multilevel mixed models. Associations with maternal socio-demographic variables, collected through questionnaires during pregnancy, were assessed using general linear models. In n = 486 infants, four dietary pattern trajectories were established from 6- to 12-months. Predominantly breastmilk: mainly breastmilk and less formula milk, rice porridge, vegetables, fruits and low-fat fish and meat, Easy-to-prepare foods: infant cereals, juices, cakes and biscuits and Noodles (in soup) and seafood: noodle and common accompaniments. In adjusted models, higher maternal education attainment was correlated with higher start scores on Predominantly breastmilk, but lowest education attainment increased its adherence over time. Older mothers had higher start scores on Easy-to-prepare foods, but younger mothers had increased adherence over time. Chinese mothers had higher start scores on Predominantly breastmilk but greater adherence to GUIDELINES over time, while Indian mothers had higher start scores on Easy-to-prepare foods but greater adherence to Predominantly breastmilk with time (p < 0.05 for all). Changes in trajectories over time were small. Hence, dietary patterns established during weaning are strongly influenced by maternal socio-demographic factors and remain stable over the first year of life.
LIBS: a potential tool for industrial/agricultural waste water analysis
NASA Astrophysics Data System (ADS)
Karpate, Tanvi; K. M., Muhammed Shameem; Nayak, Rajesh; V. K., Unnikrishnan; Santhosh, C.
2016-04-01
Laser Induced Breakdown Spectroscopy (LIBS) is a multi-elemental analysis technique with various advantages and has the ability to detect any element in real time. This technique holds a potential for environmental monitoring and various such analysis has been done in soil, glass, paint, water, plastic etc confirms the robustness of this technique for such applications. Compared to the currently available water quality monitoring methods and techniques, LIBS has several advantages, viz. no need for sample preparation, fast and easy operation, and chemical free during the process. In LIBS, powerful pulsed laser generates plasma which is then analyzed to get quantitative and qualitative details of the elements present in the sample. Another main advantage of LIBS technique is that it can perform in standoff mode for real time analysis. Water samples from industries and agricultural strata tend to have a lot of pollutants making it harmful for consumption. The emphasis of this project is to determine such harmful pollutants present in trace amounts in industrial and agricultural wastewater. When high intensity laser is made incident on the sample, a plasma is generated which gives a multielemental emission spectra. LIBS analysis has shown outstanding success for solids samples. For liquid samples, the analysis is challenging as the liquid sample has the chances of splashing due to the high energy of laser and thus making it difficult to generate plasma. This project also deals with determining the most efficient method for testing of water sample for qualitative as well as quantitative analysis using LIBS.
Qin, Yuhong; Jatamunua, Freedom; Zhang, Jingru; Li, Yanjie; Han, Yongtao; Zou, Nan; Shan, Jihao; Jiang, Yanbin; Pan, Canping
2017-05-15
The frequent use of various veterinary drugs could lead to residue bioaccumulation in animal tissues, which could cause dietary risks to human health. In order to quickly analyze the residues, a liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for detecting Sulfonamides, Tilmicosin and Avermectins (AVMs) residues in animal samples. For sample preparation, modified QuEChERS (quick, easy, cheap, effective, rugged and safe) and ultrasound-assisted extraction (UAE) methods were used. For sample cleanup, n-Hexane delipidation and multi-plug filtration cleanup (m-PFC) method based on primary-secondary amine (PSA) and octadecyl-silica (C18) were used, followed by LC-MS/MS analysis. It was validated on 7 animal matrices (bovine, caprine, swine meat and their kidneys, milk) at two fortified concentration levels of 5 and 100μg/kg. The recoveries ranged from 82 to 107% for all analytes with relative standard deviations (RSDs) less than 15%. Matrix-matched calibrations were performed with coefficients of determination above 0.998 for all analytes within concentration levels of 5-500μg/kg. The developed method was successfully used to analysis veterinary drugs of real animal samples from local markets. Copyright © 2017 Elsevier B.V. All rights reserved.
Atsukawa, Yoshiko; Kawakami, Sayoko; Asahara, Miwa; Ishigaki, Shinobu; Tanaka, Takashi; Ono, Yasuo; Nishiya, Hajime; Fujisaki, Ryuichi; Koga, Ichiro; Ota, Yasuo; Miyazawa, Yukihisa
2011-08-01
Gram staining is a useful technique for detecting bacteria but is highly questionable in detecting Mycobacterium tuberculosis. Its detection generally requires special staining, such as Ziehl-Neelsen staining. We experienced three cases in which tuberculosis was first suggested by Gram staining of sputum or pus, confirmed by Ziehl-Neelsen staining, and diagnosed by polymerase chain reaction or culture. To find colorless tubercle bacilli in clinical samples with various organisms, varying the focus to slightly longer and shorter during study of the slides is indispensable. We present criteria for detecting infective pulmonary tuberculosis in Gram staining. First, in the ordinary focus, weakly stained, thin, gram-positive bacilli are found; second, with a slightly longer focus distance, the thin, cord-like, conspicuous gram-positive bacilli can be observed; and third, with a shorter focus distance, the gram-positive bacilli have changed into the brightened, colorless, or ghost ones. Four laboratory technologists each evaluated 20 Gram-stained samples after being lectured on the criteria, with no prior information about the sample. They accurately evaluated the presence of the bacilli in Gram-stained preparations in more than 90% of samples containing 3+ bacilli on Ziehl-Neelsen staining. Gram staining is available as an easy and rapid initial clue to recognize highly infective tuberculosis.
NASA Astrophysics Data System (ADS)
Judák, Péter; Grainger, Janelle; Goebel, Catrin; Van Eenoo, Peter; Deventer, Koen
2017-08-01
The mobile phase additive (DMSO) has been described as a useful tool to enhance electrospray ionization (ESI) of peptides and proteins. So far, this technique has mainly been used in proteomic/peptide research, and its applicability in a routine clinical laboratory setting (i.e., doping control analysis) has not been described yet. This work provides a simple, easy to implement screening method for the detection of doping relevant small peptides (GHRPs, GnRHs, GHS, and vasopressin-analogues) with molecular weight less than 2 kDa applying DMSO in the mobile phase. The gain in sensitivity was sufficient to inject the urine samples after a 2-fold dilution step omitting a time consuming sample preparation. The employed analytical procedure was validated for the qualitative determination of 36 compounds, including 13 metabolites. The detection limits (LODs) ranged between 50 and 1000 pg/mL and were compliant with the 2 ng/mL minimum detection level required by the World Anti-Doping Agency (WADA) for all the target peptides. To demonstrate the feasibility of the work, urine samples obtained from patients who have been treated with desmopressin or leuprolide and urine samples that have been declared as adverse analytical findings were analyzed.
A simple competitive RT-PCR assay for quantitation of HIV-1 subtype B and non-B RNA in plasma.
Hamatake, Makiko; Nishizawa, Masako; Yamamoto, Naoki; Kato, Shingo; Sugiura, Wataru
2007-06-01
An easy, inexpensive competitive RT-PCR assay for HIV-1 RNA quantitation was constructed. A 138-bp sequence in the HIV-1 gag p24 region was selected as the target and co-amplified with competitor RNA containing an internal 44-bp deletion. Quantitation of serial dilutions of control RNA samples prepared from the LAI isolate demonstrated a good linearity (R(2)=0.991) within the range between 10 and 250 copies/sample. The detection limit of the assay was determined to be 3.8 copies/sample by Probit analysis and corresponded to 110 copies/ml in plasma. The intra-assay CV value was 9.1%, and the inter-assay value was 25.9%. Both were comparable to those obtained with commercially available HIV-1 RNA quantitation kits. The correlation efficient for the results obtained in 47 plasma samples from HIV-1-infected individuals (subtype A in 1, subtype B in 25, subtype C in 4, subtype F in 1, and CRF01 AE in 16) with the competitive RT-PCR and Cobas Amplicor HIV-1 Monitor test v1.5 was 0.956 for subtype B and 0.947 for subtype non-B. The assay devised is a good alternative for monitoring antiretroviral therapy in resource-poor countries.
Electrostatic-spray ionization mass spectrometry sniffing for perfume fingerprinting.
Tobolkina, Elena; Qiao, Liang; Xu, Guobin; Girault, Hubert H
2013-11-15
The perfume market is growing significantly, and it is easy to find imitative fragrances of probably all types of perfume. Such imitative fragrances are usually of lower quality than the authentic ones, creating a possible threat for perfume companies. Therefore, it is important to develop efficient chemical analysis techniques to screen rapidly perfume samples. Electrostatic-spray ionization (ESTASI) was used to analyze directly samples sprayed or deposited on different types of paper. A linear ion trap mass spectrometer was used to detect the ions produced by ESTASI with a modified extended transfer capillary for 'sniffing' ions from the paper. Several commercial perfumes and a model perfume were analyzed by ESTASI-sniffing. The results obtained by paper ESTASI-MS of commercial fragrances were compared with those obtained from ESI-MS. In addition, a commercial fragrance was first nebulized on the hand and then soaked up by blotting paper, which was afterwards placed on an insulating plate for ESTASI-MS analysis. Analysis of peptides and proteins was also performed to show that the paper ESTASI-MS could be used for samples with very different molecular masses. Paper ESTASI-MS yields a rapid fingerprinting characterization of perfume fragrances, avoiding time-consuming sample-preparation steps, and thereby performing a rapid screening in a few seconds. Copyright © 2013 John Wiley & Sons, Ltd.
An easily regenerable enzyme reactor prepared from polymerized high internal phase emulsions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruan, Guihua, E-mail: guihuaruan@hotmail.com; Guangxi Collaborative Innovation Center for Water Pollution Control and Water Safety in Karst Area, Guilin University of Technology, Guilin 541004; Wu, Zhenwei
A large-scale high-efficient enzyme reactor based on polymerized high internal phase emulsion monolith (polyHIPE) was prepared. First, a porous cross-linked polyHIPE monolith was prepared by in-situ thermal polymerization of a high internal phase emulsion containing styrene, divinylbenzene and polyglutaraldehyde. The enzyme of TPCK-Trypsin was then immobilized on the monolithic polyHIPE. The performance of the resultant enzyme reactor was assessed according to the conversion ability of N{sub α}-benzoyl-L-arginine ethyl ester to N{sub α}-benzoyl-L-arginine, and the protein digestibility of bovine serum albumin (BSA) and cytochrome (Cyt-C). The results showed that the prepared enzyme reactor exhibited high enzyme immobilization efficiency and fast andmore » easy-control protein digestibility. BSA and Cyt-C could be digested in 10 min with sequence coverage of 59% and 78%, respectively. The peptides and residual protein could be easily rinsed out from reactor and the reactor could be regenerated easily with 4 M HCl without any structure destruction. Properties of multiple interconnected chambers with good permeability, fast digestion facility and easily reproducibility indicated that the polyHIPE enzyme reactor was a good selector potentially applied in proteomics and catalysis areas. - Graphical abstract: Schematic illustration of preparation of hypercrosslinking polyHIPE immobilized enzyme reactor for on-column protein digestion. - Highlights: • A reactor was prepared and used for enzyme immobilization and continuous on-column protein digestion. • The new polyHIPE IMER was quite suit for protein digestion with good properties. • On-column digestion revealed that the IMER was easy regenerated by HCl without any structure destruction.« less
Strongly luminescent monolayered MoS2 prepared by effective ultrasound exfoliation.
Štengl, Václav; Henych, Jiří
2013-04-21
Intense ultrasound in a pressurized batch reactor was used for preparation of monolayered MoS2 nanosheets from natural mineral molybdenite. Exfoliation of bulk MoS2 using ultrasound is an attractive route to large-scale preparation of monolayered crystals. To evaluate the quality of delamination, methods like X-ray diffraction, Raman spectroscopy and microscopic techniques (TEM and AFM) were employed. From single- or few-layered products obtained from intense sonication, MoS2 quantum dots (MoSQDs) were prepared by a one-pot reaction by refluxing exfoliated nanosheets of MoS2 in ethylene glycol under atmospheric pressure. The synthesised MoSQDs were characterised by photoluminescence spectroscopy and laser-scattering particle size analysis. Our easy preparation leads to very strongly green luminescing quantum dots.
Gel Electrophoresis--The Easy Way for Students
ERIC Educational Resources Information Center
VanRooy, Wilhelmina; Sultana, Khalida
2010-01-01
This article describes a simple, inexpensive, easy to conduct gel-electrophoresis activity using food dyes. It is an alternative to the more expensive counterparts which require agarose gel, DNA samples, purchased chamber and Tris-borate-EDTA buffer. We suggest some learning activities for senior biology students along with comments on several…
Rearing insects on artificial diets
USDA-ARS?s Scientific Manuscript database
Insects are reared in the laboratory for various purposes. They may be reared either on their natural food or artificial diets. Developing artificial diets may be difficult and time consuming but once optimized, artificial diets usually are simple to prepare and easy to use. Because they are process...
Magnetic nano-catalysts have been prepared using simple modification of iron ferrites wherein their quasi-homogeneous state, because of nm size range, facilitates the catalysis process as increased surface is available for reaction; the easy separation of the catalysts by externa...
Why We Must Work with Arts Education.
ERIC Educational Resources Information Center
Fleischmann, Ernest
1986-01-01
Maintains that only people prepared through an arts education can truly receive and understand the benefits of civilization. Argues that we may counteract the undesirable effects of an easy, "instant response" society by focusing our collective and cooperative energies on education about the arts. (TRS)
Recent Developments of Graphene Oxide-Based Membranes: A Review
Ma, Jinxia; Ping, Dan; Dong, Xinfa
2017-01-01
Membrane-based separation technology has attracted great interest in many separation fields due to its advantages of easy-operation, energy-efficiency, easy scale-up, and environmental friendliness. The development of novel membrane materials and membrane structures is an urgent demand to promote membrane-based separation technology. Graphene oxide (GO), as an emerging star nano-building material, has showed great potential in the membrane-based separation field. In this review paper, the latest research progress in GO-based membranes focused on adjusting membrane structure and enhancing their mechanical strength as well as structural stability in aqueous environment is highlighted and discussed in detail. First, we briefly reviewed the preparation and characterization of GO. Then, the preparation method, characterization, and type of GO-based membrane are summarized. Finally, the advancements of GO-based membrane in adjusting membrane structure and enhancing their mechanical strength, as well as structural stability in aqueous environment, are particularly discussed. This review hopefully provides a new avenue for the innovative developments of GO-based membrane in various membrane applications. PMID:28895877
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Hui; Chen, Yan; Hood, Zachary D.
All-solid-state sodium batteries, using abundant sodium resources and solid electrolyte, hold much promise for safe, low cost, large-scale energy storage. To realize the practical applications of all solid Na-ion batteries at ambient temperature, the solid electrolytes are required to have high ionic conductivity, chemical stability, and ideally, easy preparation. Ceramic electrolytes show higher ionic conductivity than polymers, but they often require extremely stringent synthesis conditions, either high sintering temperature above 1000 C or long-time, low-energy ball milling. Herein, we report a new synthesis route for Na 3SbS 4, a novel Na superionic conductor that needs much lower processing temperature belowmore » 200 C and easy operation. This new solid electrolyte exhibits a remarkable ionic conductivity of 1.05 mS cm -1 at 25 °C and is chemically stable under ambient atmosphere. In conclusion, this synthesis process provides unique insight into the current state-of-the-art solid electrolyte preparation and opens new possibilities for the design of similar materials.« less
Hashmi, A Stephen K; Lauterbach, Tobias; Nösel, Pascal; Vilhelmsen, Mie Højer; Rudolph, Matthias; Rominger, Frank
2013-01-14
A series of dinuclear gold σ,π-propyne acetylide complexes were prepared and tested for their catalytic ability in dual gold catalysis that was based on the reaction of an electrophilic π-complex of gold with a gold acetylide. The air-stable and storable catalysts can be isolated as silver-free catalysts in their activated form. These dual catalysts allow a fast initiation phase for the dual catalytic cycles without the need for additional additives for acetylide formation. Because propyne serves as a throw-away ligand, no traces of the precatalyst are generated. Based on the fast initiation process, side products are minimized and reaction rates are higher for these catalysts. A series of test reactions were used to demonstrate the general applicability of these catalysts. Lower catalyst loadings, faster reaction rates, and better selectivity, combined with the practicability of these catalysts, make them ideal catalysts for dual gold catalysis. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Tian, Meng; Cui, Xueliang; Dong, Chunxu; Dong, Zhengping
2016-12-01
In this study, a novel catalyst has been prepared through supporting Pd nanoparticles (NPs) on the surface of boehmite (γ-AlOOH) based hollow aluminosilicate microspheres (HAM@γ-AlOOH). The prepared Pd/HAM@γ-AlOOH catalyst has high catalytic activity for the hydrogenation of nitroarenes to their corresponding amino derivatives with high yields at ambient conditions. The high catalytic efficiency is attributed to the large pore size of the flower-like hierarchical flakes structure of HAM@γ-AlOOH, that gives Pd NPs on the support surface easy accessibility. Moreover, the Pd/HAM@γ-AlOOH catalyst can also be easily recycled at least five times without obvious decrease of catalytic activity. This work may provide a useful method for the fabrication of supported noble metal NP-based catalysts on the surface of mesoporous hierarchical structure materials with easy accessibility and superior activity.
Recent Developments of Graphene Oxide-Based Membranes: A Review.
Ma, Jinxia; Ping, Dan; Dong, Xinfa
2017-09-12
Membrane-based separation technology has attracted great interest in many separation fields due to its advantages of easy-operation, energy-efficiency, easy scale-up, and environmental friendliness. The development of novel membrane materials and membrane structures is an urgent demand to promote membrane-based separation technology. Graphene oxide (GO), as an emerging star nano-building material, has showed great potential in the membrane-based separation field. In this review paper, the latest research progress in GO-based membranes focused on adjusting membrane structure and enhancing their mechanical strength as well as structural stability in aqueous environment is highlighted and discussed in detail. First, we briefly reviewed the preparation and characterization of GO. Then, the preparation method, characterization, and type of GO-based membrane are summarized. Finally, the advancements of GO-based membrane in adjusting membrane structure and enhancing their mechanical strength, as well as structural stability in aqueous environment, are particularly discussed. This review hopefully provides a new avenue for the innovative developments of GO-based membrane in various membrane applications.
Leong, W C
1989-04-01
This case study was the result of attending the Computer Assisted Learning (CAL) Course sponsored by the Wessex Regional CAL Project. This was the Region's initiative to prepare Nurse and Midwife Teachers in developing CAL in the curriculum. The small scale qualitative classroom study was conducted in the School of Midwifery. The aim of the study was to evaluate the use of the content-free Wessex Care Plan Program (WCPP) in the Midwifery curriculum. For the evaluation of the study, a triangulation of data were obtained from the following sources: 1) classroom observation 2) questionnaires and interviews of eight Student Midwives 3) colleagues' responses to the introduction of CAL and personal experience The findings of this study showed that the content-free WCPP was easy to prepare and implement. The Student Midwives found the program easy to follow and a useful means of learning. At the same time it was enjoyable and fun; a dimension of learning that we could do with more often!
Li, Ming; Hu, Bin; Li, Jianqiang; Chen, Rong; Zhang, Xie; Chen, Huanwen
2009-09-15
A homemade novel nanoextractive electrospray ionization (nanoEESI) source has been characterized for in situ mass spectrometric analysis of ambient samples without sample pretreatment. The primary ions generated using a nanospray emitter interact with the neutral sample plume created by manually nebulizing liquid samples, allowing production of the analyte ions in the spatial cross section of the nanoEESI source. The performance of nanoEESI is experimentally investigated by coupling the nanoEESI source to a commercial LTQ mass spectrometer for rapid analysis of various ambient samples using positive/negative ion detection modes. Compounds of interest in actual samples such as aerosol drug preparations, beverages, milk suspensions, farmland water, and groundwater were unambiguously detected using tandem nanoEESI ion trap mass spectrometry. The limit of detection was low picogram per milliliter levels for the compounds tested. Acceptable relative standard deviation (RSD) values (5-10%) were obtained for direct measurement of analytes in complex matrixes, providing linear dynamic signal responses using manual sample introduction. A single sample analysis was completed within 1.2 s. Requiring no sheath gas for either primary ion production or neutral sample introduction, the nanoEESI has advantages including readiness for miniaturization and integration, simple maintenance, easy operation, and low cost. The experimental data demonstrate that the nanoEESI is a promising tool for high-throughput, sensitive, quantitative, in situ analysis of ambient complex samples, showing potential applications for in situ analysis in multiple disciplines including but not limited to pharmaceutical analysis, food quality control, pesticides residue detection, and homeland security.
Koga, Hirotaka; Nogi, Masaya; Isogai, Akira
2017-11-22
Functional molecules play a significant role in the development of high-performance composite materials. Functional molecules should be well dispersed (ideally dissolved) and supported within an easy-to-handle substrate to take full advantage of their functionality and ensure easy handling. However, simultaneously achieving the dissolution and support of functional molecules remains a challenge. Herein, we propose the combination of a nonvolatile ionic liquid and an easy-to-handle cellulose paper substrate for achieving this goal. First, the photochromic molecule, i.e., diarylethene, was dissolved in the ionic liquid 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide ([bmim]NTf 2 ). Then, diarylethene/[bmim]NTf 2 was supported on cellulose fibers within the paper, through hydrogen bonding between [bmim] cations of the ionic liquid and the abundant hydroxyl groups of cellulose. The as-prepared paper composites exhibited reversible, rapid, uniform, and vivid coloration and bleaching upon ultraviolet and visible light irradiation. The photochromic performance was superior to that of the paper prepared in the absence of [bmim]NTf 2 . This concept could be applied to other functional molecules. For example, lithium perchlorate/[bmim] tetrafluoroborate supported within cellulose paper acted as a flexible electrolyte to provide a paper-based electrochromic device. These findings are expected to further the development of composite materials with high functionality and practicality.
Aggarwal, Vivek; Singla, Mamta; Yadav, Suman; Yadav, Harish
2014-05-01
The purpose of the present study was to comparatively evaluate the effect of flowable composite resin liner and resin modified glass ionomer liner on gingival marginal adaptation of class II cavities restored using three bonding agents (Single Bond 3M ESPE, One Coat Self Etching Bond Coltene Whaledent; Adper Easy Bond Self-Etch Adhesive 3M ESPE) and respective composite resins, under cyclic loading. The marginal adaptation was evaluated in terms of 'continuous margin' (CM) at the gingival margin. Ninety class II cavities with margins extending 1mm below the cement-enamel junction were prepared in extracted mandibular third molars. The samples were divided into three groups: no liner placement; 0.5-1mm thick flowable resin liner placement (Filtek Z350 XT flowable resin) on gingival floor and; light cure glass ionomer (Ketac N100) liner. The groups were further subdivided into three sub-groups on the basis of the bonding agents used. Cavities were restored with composite resins (Z350 for Single Bond and Adper Easy Bond; and Synergy D6 Universal, for One Coat Self Etching Bond) in 2mm increments and the samples were mechanically loaded (60N, 1,50,000 cycles). Marginal adaptation was evaluated using a low vacuum scanning electron microscope. Statistical analysis was done with two way ANOVA with Holm-Sidak's correction for multiple comparisons. Placement of flowable composite liner significantly improved the CM values of Single Bond (78±11%) and One Coat Self Etching Bond (77±9%) compared with no liner group, but the values of CM of Adper Easy Bond were not improved (61±12%). Placement of glass ionomer liner significantly improved the values of CM in all the sub-groups (78±9%, 72±10% and 77±10% for Single Bond, One Coat Self Etching Bond & Adper Easy Bond respectively) compared with no liner group. Placement of liners improved the values of 'continuous margin' in the gingival floor of the proximal cavities restored with composite resins using different bonding agent. Placement of flowable composite liner or glass ionomer liner will improve the marginal integrity of composite restorations using etch-and-rinse and two bottle-two step self etch adhesives. To improve the marginal integrity of a single bottle adhesive, glass ionomer liner should be applied. Copyright © 2014 Elsevier Ltd. All rights reserved.
Liu, Qiaoxia; Zhou, Binbin; Wang, Xinliang; Ke, Yanxiong; Jin, Yu; Yin, Lihui; Liang, Xinmiao
2012-12-01
A search library about benzylisoquinoline alkaloids was established based on preparation of alkaloid fractions from Rhizoma coptidis, Cortex phellodendri, and Rhizoma corydalis. In this work, two alkaloid fractions from each herbal medicine were first prepared based on selective separation on the "click" binaphthyl column. And then these alkaloid fractions were analyzed on C18 column by liquid chromatography coupled with tandem mass spectrometry. Many structure-related compounds were included in these alkaloids fractions, which led to easy separation and good MS response in further work. Therefore, a search library of 52 benzylisoquinoline alkaloids was established, which included eight aporphine, 19 tetrahydroprotoberberine, two protopine, two benzyltetrahydroisoquinoline, and 21 protoberberine alkaloids. The information of the search library contained compound names, structures, retention times, accurate masses, fragmentation pathways of benzylisoquionline alkaloids, and their sources from three herbal medicines. Using such a library, the alkaloids, especially those trace and unknown components in some herbal medicine could be accurately and quickly identified. In addition, the distribution of benzylisoquinoline alkaloids in the herbal medicines could be also summarized by searching the source samples in the library. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Niu, Xiaoyu; Zhao, Tieying; Yuan, Fulong; Zhu, Yujun
2015-01-01
The hollow CuO@SiO2 spheres with a mean diameter of 240 nm and a thin shell layer of about 30 nm in thickness was synthesized using an inorganic SiO2 shell coating on the surface of Cu@C composite that was prepared by a two-step hydrothermal method. The obtained hollow CuO@SiO2 spheres were characterized by ICP-AES, nitrogen adsorption-desorption, SEM, TEM, XRD, H2-TPR, CO-TPR, CO-TPD and NO-TPD. The results revealed that the hollow CuO@SiO2 spheres consist of CuO uniformly inserted into SiO2 layer. The CuO@SiO2 sample exhibits particular catalytic activities for CO oxidation and NO + CO reactions compared with CuO supported on SiO2 (CuO/SiO2). The higher catalytic activity is attributed to the special hollow shell structure that possesses much more highly dispersed CuO nanocluster that can be easy toward the CO and NO adsorption and the oxidation of CO on its surface. PMID:25777579
Jinadu, M K; Olusi, S O; Ajuwon, B
1997-03-01
This study was conducted among Yoruba women and traditional healers with the aim of identifying and describing the practice, preparation, and administration of traditional contraceptives. The data were obtained in 1990 from a random sample of 1,400 women of childbearing age and 42 traditional healers in Nigeria's Oranmiyan area, using questionnaires and in-depth interviews. Findings revealed that knowledge of the traditional contraceptives is nearly universal among the Yoruba population, and the traditional contraceptive prevalence rate is 7.1 percent. The use of traditional contraceptives was significantly more common among uneducated women and among women aged 20 to 29 years old. Findings also revealed the existence of four main varieties of traditional contraceptive devices, the methods of preparation of the traditional contraceptives, varieties of herbal and animal products used, methods of administration, and taboos against usage. The easy accessibility of traditional medical practitioners and the belief that traditional contraceptive devices are devoid of complications, especially among those experienced with modern contraceptive devices, were the main reasons women cited for patronizing the traditional practitioners. The paper concludes with policy implications for family planning programmers in Nigeria.
Lu, Liulei; Ouyang, Dong
2017-07-20
In this work, the effect of graphene oxide nanosheet (GONS) additives on the properties of cement mortar and ultra-high strength concrete (UHSC) is reported. The resulting GONS-cement composites were easy to prepare and exhibited excellent mechanical properties. However, their fluidity decreased with increasing GONS content. The UHSC specimens were prepared with various amounts of GONSs (0-0.03% by weight of cement). Results indicated that using 0.01% by weight of cement GONSs caused a 7.82% in compressive strength after 28 days of curing. Moreover, adding GONSs improved the flexural strength and deformation ability, with the increase in flexural strength more than that of compressive strength. Furthermore, field-emission scanning electron microscopy (FE-SEM) was used to observe the morphology of the hardened cement paste and UHSC samples. FE-SEM observations showed that the GONSs were well dispersed in the matrix and the bonding of the GONSs and the surrounding cement matrix was strong. Furthermore, FE-SEM observation indicated that the GONSs probably affected the shape of the cement hydration products. However, the growth space for hydrates also had an important effect on the morphology of hydrates. The true hydration mechanism of cement composites with GONSs needs further study.
A comparative study of blood smear, QBC and antigen detection for diagnosis of malaria.
Parija, S C; Dhodapkar, Rahul; Elangovan, Subashini; Chaya, D R
2009-01-01
Rapid diagnosis is prerequisite for effective treatment and reducing mortality and morbidity of malaria. This study was taken up to compare the efficacy of various methods available, i.e., thick and thin smear, quantitative buffy coat (QBC), plasmodium lactate dehydrogenase and aldolase in blood of patient. A total of 411 samples were collected from patients presenting with classic symptoms of malaria. For traditional microscopy; thick and thin smears were prepared and stained with Leishman's stain, taking thick smear as gold standard, thin smear had a sensitivity and specificity of 54.8% and 100%, respectively. QBC and antigen detection was done using commercially available kits; out of 411 samples, QBC and Malariagen were positive in 66 and 62 cases, with a sensitivity of 78% and 75%, respectively. Leishman's thick smear, although cost effective, is difficult to interpret for inexperienced microscopists; so if facilities are available, QBC should be used for routine diagnosis. In places where facilities are not available, rapid, simple and easy to interpret antigen detection test can be used despite low sensitivity.
Murillo Pulgarín, José A; García Bermejo, Luisa F; Durán, Armando Carrasquero
2018-03-07
High-performance liquid chromatography (HPLC) was used to separate oxamyl from other pesticides in drinking water and tomato paste. The eluate emerging from the column tail was mixed with an alkaline solution of Co 2+ in EDTA and irradiated with UV light to induce photolysis of the carbamate in order to obtain free radicals and other reactive species that oxidize luminol and produce chemiluminescence (CL) as a result. The intensity of the CL signal was monitored in the form of chromatographic peaks. Under the optimum operating conditions for the HPLC-UV-CL system, the analyte concentration was linearly related to peak area. The limit of detection as determined in accordance with the IUPAC criterion was 0.17 mg L -1 . Oxamyl was successfully extracted with recoveries of 88.7-103.1% from spiked tomato paste by using a simple QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) sample preparation approach. Similar recoveries were obtained from drinking water samples spiked with oxamyl concentrations above the LOD. The proposed method is a simple, fast, accurate choice for quantifying this pesticide.
Effective Pb2+ removal from water using nanozerovalent iron stored 10 months
NASA Astrophysics Data System (ADS)
Ahmed, M. A.; Bishay, Samiha T.; Ahmed, Fatma M.; El-Dek, S. I.
2017-10-01
Heavy metal removal from water required reliable and cost-effective considerations, fast separation as well as easy methodology. In this piece of research, nanozerovalent iron (NZVI) was prepared as ideal sorbent for Pb2+ removal. The sample was characterized using X-ray diffraction (XRD), high-resolution transmission electron microscope (HRTEM), and atomic force microscope (AFM-SPM). Batch experiments comprised the effect of pH value and contact time on the adsorption process. The same NZVI was stored for a shelf time (10 months) and the batch experiment was repeated. The outcomes of the investigation assured that NZVI publicized an extraordinary large metal uptake (98%) after a short contact time (10 h). The stored sample revealed the same effectiveness on Pb2+ removal under the same conditions. The results of the physical properties, magnetic susceptibility, and conductance were correlated with the adsorption efficiency. This work offers evidence that these NZVI particles could be potential candidate for Pb2+ removal in large scale, stored for a long time using a simple, green, and cost-effective methodology, and represent an actual feedback in waste water treatment.
Xing, Rongrong; Wang, Shuangshou; Bie, Zijun; He, Hui; Liu, Zhen
2017-05-01
Molecularly imprinted polymers (MIPs) are materials that are designed to be receptors for a template molecule (e.g., a protein). They are made by polymerizing the polymerizable reagents in the presence of the template; when the template is removed, the material can be used for many applications that would traditionally use antibodies. Thus, MIPs are biomimetic of antibodies and in this capacity have found wide applications, such as sensing, separation and diagnosis. However, many imprinting approaches are uncontrollable, and facile imprinting approaches widely applicable to a large variety of templates remain limited. We developed an approach called boronate affinity controllable-oriented surface imprinting, which allows for easy and efficient preparation of MIPs specific to glycoproteins, glycans and monosaccharides. This approach relies on immobilization of a template (glycoprotein, glycan or monosaccharide) on a boronic-acid-functionalized substrate through boronate affinity interaction, followed by self-polymerization of biocompatible monomer(s) to form an imprinting layer on the substrate with appropriate thickness. Imprinting in this approach is performed in a controllable manner, permitting the thickness of the imprinting layer to be fine-tuned according to the molecular size of the template by adjusting the imprinting time. This not only simplifies the imprinting procedure but also makes the approach widely applicable to a large range of sugar-containing biomolecules. MIPs prepared by this approach exhibit excellent binding properties and can be applied to complex real samples. The MIPs prepared by this protocol have been used in affinity separation, disease diagnosis and bioimaging. The entire protocol, including preparation, property characterization and performance evaluation, takes ∼3-8 d, depending on the type of substrate and template used.
Ductile transplutonium metal alloys
Conner, W.V.
1981-10-09
Alloys of Ce with transplutonium metals such as Am, Cm, Bk and Cf have properties making them highly suitable as souces of the transplutonium element, e.g., for use in radiation detector technology or as radiation sources. The alloys are ductile, homogeneous, easy to prepare and have a fairly high density.
Ductile transplutonium metal alloys
Conner, William V.
1983-01-01
Alloys of Ce with transplutonium metals such as Am, Cm, Bk and Cf have properties making them highly suitable as sources of the transplutonium element, e.g., for use in radiation detector technology or as radiation sources. The alloys are ductile, homogeneous, easy to prepare and have a fairly high density.
Easy preparation of dietary fiber with the high water-holding capacity from food sources.
Yamazaki, Eiji; Murakami, Kazumi; Kurita, Osamu
2005-03-01
Dietary fibers were prepared as alkali- and acid-insoluble fractions with chemical phosphorylation from Tossa jute (Corchorus olitorius), defatted soybean (Glycine max), and Shiitake (Lentinula edodes). The dietary fiber fractions treated with alkaline solution containing sodium metaphosphate had the lower protein content and higher total dietary fiber content than those of the preparations without phosphorylation. Alkaline extraction followed by phosphorylation led to a 1.5-fold increase in the water holding capacity of dietary fiber compared with no phosphorylation, whereas the binding capacity to bile acids of dietary fiber was almost the same. The alkali- and acid-insoluble extraction with phosphorylation provided an efficient preparation of water-insoluble dietary fiber with high-water holding capacity from various food sources.
Personalized Medicine in Pediatrics: The Clinical Potential of Orodispersible Films.
Visser, J Carolina; Woerdenbag, Herman J; Hanff, Lidwien M; Frijlink, Henderik W
2017-02-01
Children frequently receive medicines that are designed for adults. The dose of commercially available products is adapted, mostly based on the child's bodyweight, thereby neglecting differences in pharmacokinetic and pharmacodynamics parameters. If commercial products are unsuitable for administration to children or are unavailable, extemporaneous pharmacy preparations are a good alternative. For this particular population, orodispersible films (ODFs) can be a highly attractive dosage form for the oral administration of drugs. ODFs are relatively easy to prepare in a hospital setting, create dose flexibility, and may suit an individual approach, especially for patients having difficulties in swallowing tablets or being fluid restricted. In this article, various aspects related to pharmacy preparations, clinical application, and preparation of ODFs for pediatric patients are highlighted and discussed.
Grande-Martínez, Ángel; Arrebola, Francisco Javier; Moreno, Laura Díaz; Vidal, José Luis Martínez; Frenich, Antonia Garrido
2015-01-01
A rapid and sensitive multiresidue method was developed and validated for the determination of around 100 pesticides in dry samples (rice and wheat flour) by ultra-performance LC coupled to a triple quadrupole mass analyzer working in tandem mode (UPLC/QqQ-MS/MS). The sample preparation step was optimized for both matrixes. Pesticides were extracted from rice samples using aqueous ethyl acetate, while aqueous acetonitrile extraction [modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method] was used for wheat flour matrixes. In both cases the extracts were then cleaned up by dispersive solid phase extraction with MgSO4 and primary secondary amine+C18 sorbents. A further cleanup step with Florisil was necessary to remove fat in wheat flour. The method was validated at two concentration levels (3.6 and 40 μg/kg for most compounds), obtaining recoveries ranging from 70 to 120%, intraday and interday precision values≤20% expressed as RSDs, and expanded uncertainty values≤50%. The LOQ values ranged between 3.6 and 20 μg/kg, although it was set at 3.6 μg/kg for the majority of the pesticides. The method was applied to the analysis of 20 real samples, and no pesticides were detected.
NASA Astrophysics Data System (ADS)
Shen, Chuan-Chou; Lin, Huei-Ting; Chu, Mei-Fei; Yu, Ein-Fen; Wang, Xianfeng; Dorale, Jeffrey A.
2006-09-01
A new analytical technique using inductively coupled plasma-quadrupole mass spectrometry (ICP-QMS) has been developed that produces permil-level precision in the measurement of uranium concentration ([U]) and isotopic composition (δ234U) in natural materials. A 233U-236U double spike method was used to correct for mass fractionation during analysis. To correct for ratio drifting, samples were bracketed by uranium standard measurements. A sensitivity of 6-7 × 108 cps/ppm was generated with a sample solution uptake rate of 30 μL/min. With a measurement time of 15-20 min, standards of 30-ng uranium produced a within-run precision better than 3‰ (±2 R.S.D.) for δ234U and better than 2‰ for [U]. Replicate measurements made on standards show that a between-run reproducibility of 3.5‰ for δ234U and 2‰ for [U] can be achieved. ICP-QMS data of δ234U and [U] in seawater, coral, and speleothem materials are consistent with the data measured by other ICP-MS and TIMS techniques. Advantages of the ICP-QMS method include low cost, easy maintenance, simple instrumental operation, and few sample preparation steps. Sample size requirements are small, such as 10-14 mg of coral material. The results demonstrate that this technique can be applied to natural samples with various matrices.
Can excreted thiocyanate be used to detect cyanide exposure in live reef fish?
Breen, Nancy E.; Andrade, Lawrence
2018-01-01
Cyanide fishing, where a solution of sodium or potassium cyanide is used to stun reef fish for easy capture for the marine aquarium and live fish food trades, continues to be pervasive despite being illegal in many countries and destructive to coral reef ecosystems. Currently, there is no easy, reliable and universally accepted method to detect if a fish has been exposed to cyanide during the capture process. A promising non-invasive technique for detecting thiocyanate ions, the metabolic byproduct excreted by exposed fish, has been reported in the literature. In an effort to validate this method, four cyanide exposure studies on Amphiprion ocellaris (common clownfish) were carried out over three years. Fish were either exposed to the same (25 ppm) or twice the concentration (50 ppm) as the previsouly published method. Over 100 water samples of fish exposed to cyanide were analyzed by reverse phase HPLC with a C30 column treated with polyethylene glycol and UV detector operating at 220 nm. No thiocyanate was detected beyond the analytical standards and positive controls prepared in seawater. As an alternate means of detecting thiocyanate, water samples and thiocyanate standards from these exposures were derivatized with monobromobimane (MBB) for LC-MS/MS analysis. Thiocyanate was detected in standards with concentrations as low as 0.6 μg/L and quantified to 1 μg/L, but thiocyanate could not be detected in any of the water samples from fish exposed to cyanide with this method either, confirming the HPLC results. Further, we calculated both the mass balance of thiocyanate and the resultant plausible dosage of cyanide from the data reported in the previously published method. These calculations, along with the known lethal dosage of cyanide, further suggests that the detection of thiocyanate in aquarium water is not a viable method for assessing fish exposure to cyanide. PMID:29847597
Megger, Dominik A; Padden, Juliet; Rosowski, Kristin; Uszkoreit, Julian; Bracht, Thilo; Eisenacher, Martin; Gerges, Christian; Neuhaus, Horst; Schumacher, Brigitte; Schlaak, Jörg F; Sitek, Barbara
2017-02-10
The proteome analysis of bile fluid represents a promising strategy to identify biomarker candidates for various diseases of the hepatobiliary system. However, to obtain substantive results in biomarker discovery studies large patient cohorts necessarily need to be analyzed. Consequently, this would lead to an unmanageable number of samples to be analyzed if sample preparation protocols with extensive fractionation methods are applied. Hence, the performance of simple workflows allowing for "one sample, one shot" experiments have been evaluated in this study. In detail, sixteen different protocols implying modifications at the stages of desalting, delipidation, deglycosylation and tryptic digestion have been examined. Each method has been individually evaluated regarding various performance criteria and comparative analyses have been conducted to uncover possible complementarities. Here, the best performance in terms of proteome coverage has been assessed for a combination of acetone precipitation with in-gel digestion. Finally, a mapping of all obtained protein identifications with putative biomarkers for hepatocellular carcinoma (HCC) and cholangiocellular carcinoma (CCC) revealed several proteins easily detectable in bile fluid. These results can build the basis for future studies with large and well-defined patient cohorts in a more disease-related context. Human bile fluid is a proximal body fluid and supposed to be a potential source of disease markers. However, due to its biochemical composition, the proteome analysis of bile fluid still represents a challenging task and is therefore mostly conducted using extensive fractionation procedures. This in turn leads to a high number of mass spectrometric measurements for one biological sample. Considering the fact that in order to overcome the biological variability a high number of biological samples needs to be analyzed in biomarker discovery studies, this leads to the dilemma of an unmanageable number of necessary MS-based analyses. Hence, easy sample preparation protocols are demanded representing a compromise between proteome coverage and simplicity. In the presented study, such protocols have been evaluated regarding various technical criteria (e.g. identification rates, missed cleavages, chromatographic separation) uncovering the strengths and weaknesses of various methods. Furthermore, a cumulative bile proteome list has been generated that extends the current bile proteome catalog by 248 proteins. Finally, a mapping with putative biomarkers for hepatocellular carcinoma (HCC) and cholangiocellular carcinoma (CCC) derived from tissue-based studies, revealed several of these proteins being easily and reproducibly detectable in human bile. Therefore, the presented technical work represents a solid base for future disease-related studies. Copyright © 2016 Elsevier B.V. All rights reserved.
Flint, Robert B; Mian, Paola; van der Nagel, Bart; Slijkhuis, Nuria; Koch, Birgit C P
2017-04-01
Acetaminophen (APAP, paracetamol) is the most commonly used drug for pain and fever in both the United States and Europe and is considered safe when used at registered dosages. Nevertheless, differences between specific populations lead to remarkable changes in exposure to potentially toxic metabolites. Furthermore, extended knowledge is required on metabolite formation after intoxication, to optimize antidote treatment. Therefore, the authors aimed to develop and validate a quick and easy analytical method for simultaneous quantification of APAP, APAP-glucuronide, APAP-sulfate, APAP-cysteine, APAP-glutathione, APAP-mercapturate, and protein-derived APAP-cysteine in human plasma by ultraperformance liquid chromatography-electrospray ionization-tandem mass spectrometry. The internal standard was APAP-D4 for all analytes. Chromatographic separation was achieved with a reversed-phase Acquity ultraperformance liquid chromatography HSS T3 column with a runtime of only 4.5 minutes per injected sample. Gradient elution was performed with a mobile phase consisting of ammonium acetate, formic acid in Milli-Q ultrapure water or in methanol at flow rate of 0.4 mL/minute. A plasma volume of only 10 μL was required to achieve both adequate accuracy and precision. Calibration curves of all 6 analytes were linear. All analytes were stable for at least 48 hours in the autosampler; the high quality control of APAP-glutathione was stable for 24 hours. The method was validated according to the U.S. Food and Drug Administration guidelines. This method allows quantification of APAP and 6 metabolites, which serves purposes for research, as well as therapeutic drug monitoring. The advantage of this method is the combination of minimal injection volume, a short runtime, an easy sample preparation method, and the ability to quantify APAP and all 6 metabolites.
Yu, Xi; Sun, Ying; Jiang, Chunzhu; Sun, Xiumin; Gao, Yan; Wang, Yuanpeng; Zhang, Hanqi; Song, Daqian
2012-08-30
In this study, the polystyrene-coated magnetic nanoparticles (MNPs/PSt) were successfully prepared and characterized by Fourier transform infrared spectroscopy, transmission electron microscopy and vibrating sample magnetometry. The as-prepared MNPs/PSt were used as the adsorbent in magnetic solid phase extraction of five pyrethroids, including lambda-cyhalothrin, deltamethrin, esfenvalerate, permethrin, bifenthrin, in environmental water samples. The five pyrethroids were determined by ultra fast liquid chromatography-ultraviolet spectrometry. The influencing factors, including amount of MNPs/Pst, extraction time, pH value, type and volume of desorption solvent and desorption time, were examined and optimized. The extraction recoveries obtained with merely 50mg of MNPs/Pst were very satisfactory. The whole extraction process could be completed within 0.5h. The MNPs/PSt can be reused after an easy washing process. Thus, a simple, green, economical, time saving and effective method for pyrethroids analysis in environmental water samples was established. A high enrichment factor of 500 was achieved and the limits of detection for lambda-cyhalothrin, deltamethrin, esfenvalerate, permethrin, bifenthrin were 0.015±0.001 ng mL(-1), 0.012±0.001 ng mL(-1), 0.026±0.001 ng mL(-1), 0.020±0.001 ng mL(-1), 0.013±0.001 ng mL(-1), respectively. Recoveries obtained by analyzing spiked water samples at three concentration levels (0.100±0.001 ng mL(-1), 1.000±0.001 ng mL(-1), 10.000±0.001 ng mL(-1)) were between 78.97±8.38% and 96.05±8.38%. The standard curves for the five pyrethroids showed good linearity with the correlation coefficients in the range of 0.9994-0.9999. The intra-day and inter-day precision were satisfactory with the RSDs in the range of 2.05-5.52% and 2.73-8.38%, respectively. Copyright © 2012 Elsevier B.V. All rights reserved.
Florez, Diego Hernando Ângulo; Teixeira, Roseane Andrade; da Silva, Ricky Cássio Santos; Pires, Bruna Carneiro; Dutra, Flávia Viana Avelar; Borges, Keyller Bastos
2018-05-01
In this work, we developed a HPLC method for the multidetermination of avermectins (AVM) (abamectin-ABA 1b and ABA 1a, eprinomectin-EPR, and ivermectin-IVM) and milbemycins (moxidectin-MOX) in milk samples using polypyrrole (PPy) as adsorbent material in pipette-tip solid-phase extraction (PT-PPy-SPE). PPy was characterized by scanning electron microscopy, thermogravimetric analysis, Fourier transform infrared spectroscopy, and X-ray diffraction and the data agreed with the literature. The sample preparation included the clean-up of the milk by protein precipitation (PP) with acetonitrile and extraction of the analytes by PT-PPy-SPE. The chromatographic method was developed in reverse phase and isocratic mode with flow rate at 1.2 mL min -1 and ultraviolet detection at 250 nm. The mobile phase composition was acetonitrile:methanol:water (55:25:20, v/v/v). The studied parameters and the optimized conditions for the sample preparation were washing solvent (300 μL water), volume and type of eluent (500 μL methanol), volume and pH of sample (1 mL and pH 10), amount of adsorbent material (50 mg PPy), and without addition of salt (NaCl). The method was linear over the concentration range from 20 to 3000 ng mL -1 with coefficients of correlation (r) ≥ 0.99 for all analytes and recoveries around 100%. The method developed and validated was used for the analyses of real milk samples from cow treated with Ivomec ® (IVM 3.5%), in which were found 21.51 ± 2.94 ng mL -1 of IVM. Finally, the results proved that PT-PPy-SPE coupled to HPLC-UV was economical, simple, and easy-to-perform technique. Graphical abstract Pipette-tip solid phase extraction using polypirrole as adsorbent material for determination of avermectins and milbemycins in milk.
Introducing Human Population Biology through an Easy Laboratory Exercise on Mitochondrial DNA
ERIC Educational Resources Information Center
Pardinas, Antonio F.; Dopico, Eduardo; Roca, Agustin; Garcia-Vazquez, Eva; Lopez, Belen
2010-01-01
This article describes an easy and cheap laboratory exercise for students to discover their own mitochondrial haplogroup. Students use buccal swabs to obtain mucosa cells as noninvasive tissue samples, extract DNA, and with a simple polymerase chain reaction-restriction fragment length polymorphism analysis they can obtain DNA fragments of…
The nail and hair in forensic science.
Daniel, C Ralph; Piraccini, Bianca Maria; Tosti, Antonella
2004-02-01
Drugs, chemicals, and biological substances accumulate and are stored in hair and nails where they can be detected and measured. Advantages of analyzing hair and nail samples also include their easy and non-invasive collection, the small sample size required for analysis, and their easy storage at room temperature. We report 3 examples of heavy metal poisoning diagnosed because of the hair or nail symptoms. Drugs and toxins that can be detected in hair and nails are reviewed and the application of hair/nail analysis in general and in forensic medicine is discussed.
Li, Xuewei; Lei, Zhiwu; Qu, Jun; Li, Zhao; Zhou, Xiaowen; Zhang, Qiwu
2017-01-15
The goal of this study is aimed to develop a novel process to recycle the ferrous sulfate, the by-product of titanium dioxide industry. Zinc sulfate was added in the process of milling ferrous sulfate with calcium carbonate (CaCO 3 ). The sulfates were transformed into carbonates to serve as slow-release fertilizers by co-grinding the starting materials of FeSO 4 ·7H 2 O, ZnSO 4 ·7H 2 O, and CaCO 3 with small amounts of water in a planetary ball mill. The prepared samples were characterized by X-ray diffraction (XRD) analysis and quantitative measurements of the soluble ratios in water and 2% citric acid solution. It was found that Fe and Zn ions as sulfates were successfully combined with CaCO 3 to form the corresponding Fe and Zn carbonates respectively. After milling, the release ratios of Fe and Zn nutrients in distilled water could be controlled at 0.1% and 0.7% respectively. Meanwhile, the release ratios of them in 2% citric acid solution were almost 98% and 100%. Milling speed was the critical parameter to facilitate the transformation reaction. The proposed process, as an easy and economical route, exhibits evident advantages, namely allowing the use of widely available and low-cost CaCO 3 as well as industrial wastes of heavy metal sulfates as starting samples to prepare applicable products. Copyright © 2016 Elsevier Ltd. All rights reserved.
Scarano, Luigi; Mormile, Amalia; Barile, Maria; Palma, Giuseppe; Murru, Nicoletta
2014-01-01
Fishery products have always been an important food in Italy. In the past, increased consumption was mainly due to the good quality of the products, easiness of use and their beneficial effects on health. Recently, owing to the national financial crisis, there has been a decline in the consumption of fish. In fact, in 2013, according to data from ISMEA, the consumption of fresh fish suffered a sharp contraction (-5%). This decline also concerns anchovy (Engraulis encrasicolus). This species, partly because of its low price, is a mainstay of traditional Italian food. The aim of this study was to evaluate sensorial, chemical and microbiological properties of anchovy-based (Engraulis encrasicolus) products during storage at 4 and -20°C. Fresh anchovies, obtained from the wholesale fish market of Pozzuoli (Southern Italy) were cut into small pieces and hand-prepared using bread, eggs, cheese and lemon juice. Samples were analysed after 0, 2, 4, 6 and 8 days of storage at 4°C. An aliquot was quickly frozen and analysed after 34 days at -20°C. Sensory assessment, microbiological (specific spoilage organisms, Listeria spp. and Salmonella spp.) and chemical (histamine, total volatile basic nitrogen, trimethylamine, thiobarbituric acid, pH and aw) analyses were performed. Results showed that the shelf life of anchovy products was less than 5 days for the samples stored at 4°C. At -20°C, all anchovies preparations showed good sensory, microbiological and chemical properties for 34 days. PMID:27800315
Kumaravel, Ammasai; Chandrasekaran, Maruthai
2015-07-15
A rapid and simple method of determination of chlorpyrifos is important in environmental monitoring and quality control. Electrochemical methods for the determination of pesticides are fast, sensitive, reproducible, and cost-effective. The key factor in electrochemical methods is the choice of suitable electrode materials. The electrode materials should have good stability, reproducibility, more sensitivity, and easy method of preparation. Mercury-based electrodes have been widely used for the determination of chlorpyrifos. From an environmental point of view mercury cannot be used. In this study a biocompatible nano-TiO2/cellulose acetate modified glassy carbon electrode was prepared by a simple method and used for the electrochemical sensing of chlorpyrifos in aqueous methanolic solution. Electroanalytical techniques such as cyclic voltammetry, differential pulse voltammetry, and amperometry were used in this work. This electrode showed very good stability, reproducibility, and sensitivity. A well-defined peak was obtained for the reduction of chlorpyrifos in cyclic voltammetry and differential pulse voltammetry. A smooth noise-free current response was obtained in amperometric analysis. The peak current obtained was proportional to the concentration of chlorpyrifos and was used to determine the unknown concentration of chlorpyrifos in the samples. Analytical parameters such as LOD, LOQ, and linear range were estimated. Analysis of real samples was also carried out. The results were validated through HPLC. This composite electrode can be used as an alternative to mercury electrodes reported in the literature.
Vassena, Eliana; Gerrits, Robin; Demanet, Jelle; Verguts, Tom; Siugzdaite, Roma
2018-04-26
Preparing for a mentally demanding task calls upon cognitive and motivational resources. The underlying neural implementation of these mechanisms is receiving growing attention because of its implications for professional, social, and medical contexts. While several fMRI studies converge in assigning a crucial role to a cortico-subcortical network including Anterior Cigulate Cortex (ACC) and striatum, the involvement of Dorsolateral Prefrontal Cortex (DLPFC) during mental effort anticipation has yet to be replicated. This study was designed to target DLPFC contribution to anticipation of a difficult task using functional Near Infrared Spectroscopy (fNIRS), as a more cost-effective tool measuring cortical hemodynamics. We adapted a validated mental effort task, where participants performed easy and difficult mental calculation, and measured DLPFC activity during the anticipation phase. As hypothesized, DLPFC activity increased during anticipation of a hard task as compared to an easy task. Besides replicating previous fMRI work, these results establish fNIRS as an effective tool to investigate cortical contributions to anticipation of effortful behavior. This is especially useful if one requires testing large samples (e.g., to target individual differences), populations with contraindication for functional MRI (e.g., infants or patients with metal implants), or subjects in more naturalistic environments (e.g., work or sport). Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Synthesized tissue-equivalent dielectric phantoms using salt and polyvinylpyrrolidone solutions.
Ianniello, Carlotta; de Zwart, Jacco A; Duan, Qi; Deniz, Cem M; Alon, Leeor; Lee, Jae-Seung; Lattanzi, Riccardo; Brown, Ryan
2018-07-01
To explore the use of polyvinylpyrrolidone (PVP) for simulated materials with tissue-equivalent dielectric properties. PVP and salt were used to control, respectively, relative permittivity and electrical conductivity in a collection of 63 samples with a range of solute concentrations. Their dielectric properties were measured with a commercial probe and fitted to a 3D polynomial in order to establish an empirical recipe. The material's thermal properties and MR spectra were measured. The empirical polynomial recipe (available at https://www.amri.ninds.nih.gov/cgi-bin/phantomrecipe) provides the PVP and salt concentrations required for dielectric materials with permittivity and electrical conductivity values between approximately 45 and 78, and 0.1 to 2 siemens per meter, respectively, from 50 MHz to 4.5 GHz. The second- (solute concentrations) and seventh- (frequency) order polynomial recipe provided less than 2.5% relative error between the measured and target properties. PVP side peaks in the spectra were minor and unaffected by temperature changes. PVP-based phantoms are easy to prepare and nontoxic, and their semitransparency makes air bubbles easy to identify. The polymer can be used to create simulated material with a range of dielectric properties, negligible spectral side peaks, and long T 2 relaxation time, which are favorable in many MR applications. Magn Reson Med 80:413-419, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Quantum key distribution with prepare-and-measure Bell test
Tan, Yong-gang
2016-01-01
The prepare-and-measure quantum key distribution (QKD) has the merits of fast speed, high key generation rate, and easy implementation. However, the detector side channel attacks greatly undermine the security of the key bits. The eavesdropper, Eve, exploits the flaws of the detectors to obtain illegal information without violating quantum principles. It means that she can intervene in the communication without being detected. A prepare-and-measure Bell test protocol will be proposed. By randomly carrying out Bell test at the side of the information receiver, Bob, Eve’s illegal information gain within the detector side channel attack can be well bounded. This protocol does not require any improvement on the detectors used in available prepare-and-measure QKD. Though we only illustrate its application in the BB84 protocol, it is applicable for any prepare-and-measure QKD. PMID:27733771
[Classical and molecular methods for identification and quantification of domestic moulds].
Fréalle, E; Bex, V; Reboux, G; Roussel, S; Bretagne, S
2017-12-01
To study the impact of the constant and inevitable inhalation of moulds, it is necessary to sample, identify and count the spores. Environmental sampling methods can be separated into three categories: surface sampling is easy to perform but non quantitative, air sampling is easy to calibrate but provides time limited information, and dust sampling which is more representative of long term exposure to moulds. The sampling strategy depends on the objectives (evaluation of the risk of exposure for individuals; quantification of the household contamination; evaluation of the efficacy of remediation). The mould colonies obtained in culture are identified using microscopy, Maldi-TOF, and/or DNA sequencing. Electrostatic dust collectors are an alternative to older methods for identifying and quantifying household mould spores. They are easy to use and relatively cheap. Colony counting should be progressively replaced by quantitative real-time PCR, which is already validated, while waiting for more standardised high throughput sequencing methods for assessment of mould contamination without technical bias. Despite some technical recommendations for obtaining reliable and comparable results, the huge diversity of environmental moulds, the variable quantity of spores inhaled and the association with other allergens (mites, plants) make the evaluation of their impact on human health difficult. Hence there is a need for reliable and generally applicable quantitative methods. Copyright © 2017 SPLF. Published by Elsevier Masson SAS. All rights reserved.
Direct Satellite Communication. Easy-to-Prepare Hardware.
ERIC Educational Resources Information Center
Tillery, John
1990-01-01
Described is the use of the microcomputer and interfacing equipment to obtain weather data from meteorological satellites. Equipment necessary for this type of remote sensing, including constructing and/or obtaining the necessary hardware and software is discussed. Ideas for the integration of this material into the curriculum are presented. (CW)
It's Time to Transition to Production, Now What?
NASA Technical Reports Server (NTRS)
Jansma, P. A.; Montgomery, Marc; Werntz, David; Payne, Michael
1999-01-01
When it's time to transition to production, it's easy to be too focused on the application itself and to overlook some areas crucial to your success. Learn about the 10 transition tasks that will ensure a smooth transition, and will prepare your organization to operate and use your system effectively.
Phenylketonuria Genetic Screening Simulation
ERIC Educational Resources Information Center
Erickson, Patti
2012-01-01
After agreeing to host over 200 students on a daylong genetics field trip, the author needed an easy-to-prepare genetics experiment to accompany the DNA-necklace and gel-electrophoresis activities already planned. One of the student's mothers is a pediatric physician at the local hospital, and she suggested exploring genetic-disease screening…
77 FR 21383 - Education and Sharing Day, U.S.A., 2012
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-09
... stewardship from throughout the community-- from parents and caregivers who inspire a love of learning to... demonstrated a fundamental commitment to compassion, cooperation, and goodwill toward others-- doing not what is easy, but what is right. These qualities have come to define us, and as we prepare today's...
Food products for space applications
NASA Technical Reports Server (NTRS)
Cope, P. S.; Larson, R. W.
1968-01-01
Specially-prepared foodstuffs supply an astronaut with a diet containing his basic nutritional requirements in a form that is useful in his enironment. Several edible coatings preserve foods and give loose foods form and firmness. These coatings aid in packaging and give the food slip for easy removal from the package.
Code of Federal Regulations, 2012 CFR
2012-04-01
... alternatives. Rather, those proposing the change should decide which blood quantum is to be submitted to the....20 Ballots. (a) Ballots are to be prepared clearly and simply so that it is easy for the voters to... petitioners propose to reduce the one-half degree blood quantum required to qualify for membership but want...
Code of Federal Regulations, 2013 CFR
2013-04-01
... alternatives. Rather, those proposing the change should decide which blood quantum is to be submitted to the....20 Ballots. (a) Ballots are to be prepared clearly and simply so that it is easy for the voters to... petitioners propose to reduce the one-half degree blood quantum required to qualify for membership but want...
Code of Federal Regulations, 2014 CFR
2014-04-01
... alternatives. Rather, those proposing the change should decide which blood quantum is to be submitted to the....20 Ballots. (a) Ballots are to be prepared clearly and simply so that it is easy for the voters to... petitioners propose to reduce the one-half degree blood quantum required to qualify for membership but want...
Code of Federal Regulations, 2011 CFR
2011-04-01
... alternatives. Rather, those proposing the change should decide which blood quantum is to be submitted to the....20 Ballots. (a) Ballots are to be prepared clearly and simply so that it is easy for the voters to... petitioners propose to reduce the one-half degree blood quantum required to qualify for membership but want...
Code of Federal Regulations, 2010 CFR
2010-04-01
... alternatives. Rather, those proposing the change should decide which blood quantum is to be submitted to the....20 Ballots. (a) Ballots are to be prepared clearly and simply so that it is easy for the voters to... petitioners propose to reduce the one-half degree blood quantum required to qualify for membership but want...
Quick, easy to prepare freeze-dried soups
NASA Technical Reports Server (NTRS)
Ramirez, R. V.; Larson, R. W.
1972-01-01
Major advantages of soups are that they totally rehydrate in less than five minutes in water at approximately 150 deg F, maintain flavor and quality stability for two weeks in a 100 F environment, and remain stable for considerably longer at ambient temperatures. They are suitable for either household or field use.
Demonstration Experiments in Physics
ERIC Educational Resources Information Center
Sutton, Richard M.
2003-01-01
This book represents a "cookbook" for teachers of physics, a book of recipes for the preparation of demonstration experiments to illustrate the principles that make the subject of physics so fascinating. Illustrations and explanations of each demonstration are done in an easy-to-understand format. Each can be adapted to be used as a demonstration…
The Educator's Role in Preparing Visually Literate Learners
ERIC Educational Resources Information Center
Metros, Susan E.
2008-01-01
Contemporary culture has become increasingly dependent on the visual, especially for its capacity to communicate instantly and universally. Advances in technology fueled this shift. Students must learn to cope with and intelligently contribute to a culture rife with easy access to the visually rich Web, photo dependant social networks, video…
NASA Astrophysics Data System (ADS)
Khoobi, Mehdi; Delshad, Tayebeh Modiri; Vosooghi, Mohsen; Alipour, Masoumeh; Hamadi, Hosein; Alipour, Eskandar; Hamedani, Majid Pirali; Sadat ebrahimi, Seyed Esmaeil; Safaei, Zahra; Foroumadi, Alireza; Shafiee, Abbas
2015-02-01
A novel magnetically separable catalyst was prepared based on surface modification of Fe3O4 magnetic nanoparticle (MNPs) with polyethyleneimine (PEI) via covalent bonding. [3-(2,3-Epoxypropoxy)propyl]trimethoxysilane (EPO) was used as cross linker to bond PEI on the surface of MNPs with permanent stability in contrast to PEI coating via electrostatic interactions. The synthesized catalyst was characterized by Fourier transform infrared (FT-IR), thermogravimetric analysis (TGA), X-ray powder diffraction (XRD), transmission electron microscopy (TEM) and vibrating sample magnetometry (VSM). The catalyst show high efficiency for one-pot synthesis of 2-amino-3-cyano-4H-pyran derivatives via multi-component reaction (MCR). This procedure offers the advantages of green reaction media, high yield, short reaction time, easy purification of the products and simple recovery and reuse of the catalyst by simple magnetic decantation without significant loss of catalytic activity.
NASA Astrophysics Data System (ADS)
Kayed, Kamal
2018-06-01
The aim of this paper is to investigate the relationship between the micro structure and the surface charge effect resulted during XPS surface analysis of amorphous carbon nitride thin films prepared by laser ablation method. The study results show that the charge effect coefficient (E) is not just a correction factor. We found that the changes in this coefficient value due to incorporation of nitrogen atoms into the carbon network are related to the spatial configurations of the sp2 bonded carbon atoms, order degree and sp2 clusters size. In addition, results show that the curve E vs. C(sp3)-N is a characteristic curve of the micro structure. This means that using this curve makes it easy to sorting the samples according to the micro structure (hexagonal rings or chains).
Detection of vancomycin resistances in enterococci within 3 1/2 hours
NASA Astrophysics Data System (ADS)
Schröder, U. -Ch.; Beleites, C.; Assmann, C.; Glaser, U.; Hübner, U.; Pfister, W.; Fritzsche, W.; Popp, J.; Neugebauer, U.
2015-02-01
Vancomycin resistant enterococci (VRE) constitute a challenging problem in health care institutions worldwide. Novel methods to rapidly identify resistances are highly required to ensure an early start of tailored therapy and to prevent further spread of the bacteria. Here, a spectroscopy-based rapid test is presented that reveals resistances of enterococci towards vancomycin within 3.5 hours. Without any specific knowledge on the strain, VRE can be recognized with high accuracy in two different enterococci species. By means of dielectrophoresis, bacteria are directly captured from dilute suspensions, making sample preparation very easy. Raman spectroscopic analysis of the trapped bacteria over a time span of two hours in absence and presence of antibiotics reveals characteristic differences in the molecular response of sensitive as well as resistant Enterococcus faecalis and Enterococcus faecium. Furthermore, the spectroscopic fingerprints provide an indication on the mechanisms of induced resistance in VRE.
Kara, Derya; Fisher, Andrew; Foulkes, Mike; Hill, Steve J
2010-01-01
A simple, easy to use and selective spectrofluorimetric method for the determination of trace levels of gallium has been developed. A new Schiff base, N-o-vanillidine-2-amino-p-cresol (OVAC) was synthesized and its fluorescence activity with gallium investigated. Based on this chelation reaction, a spectrofluorimetric method has been developed for the determination of gallium in synthetically prepared Ga-U and Ga-As samples buffered at pH 4.0 using acetic acid-sodium acetate. The chelation reaction between Ga(III) and N-o-vanillidine-2-amino-p-cresol was very fast, requiring only 30min at room temperature to complex completely. The limit of detection (LOD) (3sigma) for Ga(III) was 7.17 nM (0.50 microgL(-1)), determined from the analysis of 11 different solutions of 20 microg L(-1) Ga(III). Copyright 2009 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henk, C.; Garner, J.; Wandersee, J.H.
1994-12-31
We acquired and loaned several durable, easy-to use, though expensive video-probe microscopes. This hand-held, automatically focusing instrument can be used by a five year old and provides instant, excellent, in-focus images up to 200X on a video screen visible to all students simultaneously. The teacher is thus freed from the technical and logistic considerations involved in conventional classroom microscopy. K-12 teachers preview our videotape on probe utilization. They assemble and demonstrate the unit in the presence of our personnel, then check out the probe for use in their own classrooms. Extremely enthusiastic students examine samples ranging from their own fingerprintsmore » and clothing (on TV!) to pond water, prepared microscope slides, and microscope polarizing light phenomena. Teachers report heightened interest in conventional microscope use once the {open_quotes}microscopy connection{close_quotes} has been made.« less
Zinc metal complex as a sensor for simultaneous detection of fluoride and HSO4(-) ions.
Singh, Jasminder; Yadav, Manisha; Singh, Ajnesh; Singh, Narinder
2015-07-28
A Schiff base based tripodal receptor was synthesized and complexed with a zinc metal ion (n17) using a very easy single step process. The resulting complex was fully characterized by CHN and single crystal XRD. The real time application of the complex in aqueous media was devised by preparing its organic nanoparticles (ONPs) and their sensor activity was tested with various anions by observing changes in the fluorescence profile of n17. It was observed that ONPs of n17 responded excellently for fluoride and sulfate, producing two different signals, with detection limits of 4.84 × 10(-12) M and 5.67 × 10(-9) M respectively, without having any interference from each other. The real time application of the sensor was also tested using various samples collected from various daily utility items and found to respond exceptionally well.
NASA Astrophysics Data System (ADS)
Zhang, J. J.; Gao, H. M.; Yan, Y.; Bai, X.; Su, F.; Wang, W. Q.; Du, X. B.
2012-10-01
CeCo5 permanent magnetic alloy has been processed by surfactant assisted high energy ball milling. Heptane and oleic acid were used as the solvent and surfactant, respectively. The amount of surfactant used was 50% by weight of the starting powder. The produced particles were deposited on a piece of copper (4 mm in length and width) under a magnetic field of 27 kOe applied along the copper surface and immobilized by ethyl α-cyanoacrylate. Scanning electron microscope pictures show that the particles are flakes, several μm in length and width and tens of nm in thickness. X-ray diffraction patterns and magnetic measurements prove that the flakes are crystalline with c-axes magnetic anisotropy. The easy magnetization axis is oriented perpendicular to the surface of the flake. A maximum coercivity of 3.3 kOe was obtained for the sample milled for 40 min.
Znaleziona, Joanna; Ginterová, Pavlína; Petr, Jan; Ondra, Peter; Válka, Ivo; Ševčík, Juraj; Chrastina, Jan; Maier, Vítězslav
2015-05-18
Synthetic cannabinoids have gained popularity due to their easy accessibility and psychoactive effects. Furthermore, they cannot be detected in urine by routine drug monitoring. The wide range of active ingredients in analyzed matrices hinders the development of a standard analytical method for their determination. Moreover, their possible side effects are not well known which increases the danger. This review is focused on the sample preparation and the determination of synthetic cannabinoids in different matrices (serum, urine, herbal blends, oral fluid, hair) published since 2004. The review includes separation and identification techniques, such as thin layer chromatography, gas and liquid chromatography and capillary electrophoresis, mostly coupled with mass spectrometry. The review also includes results by spectral methods like infrared spectroscopy, nuclear magnetic resonance or direct-injection mass spectrometry. Copyright © 2015 Elsevier B.V. All rights reserved.
Shahini, Mehdi; Yeow, John T W
2011-08-12
We report on the enhancement of electrical cell lysis using carbon nanotubes (CNTs). Electrical cell lysis systems are widely utilized in microchips as they are well suited to integration into lab-on-a-chip devices. However, cell lysis based on electrical mechanisms has high voltage requirements. Here, we demonstrate that by incorporating CNTs into microfluidic electrolysis systems, the required voltage for lysis is reduced by half and the lysis throughput at low voltages is improved by ten times, compared to non-CNT microchips. In our experiment, E. coli cells are lysed while passing through an electric field in a microchannel. Based on the lightning rod effect, the electric field strengthened at the tip of the CNTs enhances cell lysis at lower voltage and higher throughput. This approach enables easy integration of cell lysis with other on-chip high-throughput sample-preparation processes.
Analysis of Circadian Leaf Movements.
Müller, Niels A; Jiménez-Gómez, José M
2016-01-01
The circadian clock is a molecular timekeeper that controls a wide variety of biological processes. In plants, clock outputs range from the molecular level, with rhythmic gene expression and metabolite content, to physiological processes such as stomatal conductance or leaf movements. Any of these outputs can be used as markers to monitor the state of the circadian clock. In the model plant Arabidopsis thaliana, much of the current knowledge about the clock has been gained from time course experiments profiling expression of endogenous genes or reporter constructs regulated by the circadian clock. Since these methods require labor-intensive sample preparation or transformation, monitoring leaf movements is an interesting alternative, especially in non-model species and for natural variation studies. Technological improvements both in digital photography and image analysis allow cheap and easy monitoring of circadian leaf movements. In this chapter we present a protocol that uses an autonomous point and shoot camera and free software to monitor circadian leaf movements in tomato.
Hornish, Rex E; Hamlow, Philip J; Brown, Scott A
2003-01-01
A multilaboratory trial for determining ceftiofur-related residues in bovine and swine kidney and muscle, and bovine milk was conducted following regulatory guidelines of the U.S. Food and Drug Administration, Center for Veterinary Medicine. The methods convert all desfuroylceftiofur-related residues containing the intact beta-lactam ring to desfuroylceftiofur acetamide to establish ceftiofur residues in tissues. Four laboratories analyzed 5 sets of samples for each tissue. Each sample set consisted of a control/blank sample and 3 control samples fortified with ceftiofur at 0.5 Rm, Rm, and 2 Rm, respectively, where Rm is the U.S. tolerance assigned for ceftiofur residue in each tissue/matrix: 0.100 microg/mL for milk, 8.0 microg/g for kidney (both species), 1.0 microg/g for bovine muscle, and 2.0 microg/g for swine muscle. Each sample set also contained 2 samples of incurred-residue tissues (one > Rm and one < Rm) from animals treated with ceftiofur hydrochloride. All laboratories completed the method trial after a familiarization phase and test of system suitability in which they demonstrated > 80% recovery in pretrial fortified test samples. Results showed that the methods met all acceptable performance criteria for recovery, accuracy, and precision. Although sample preparation was easy, solid-phase extraction cartridge performance must be carefully evaluated before samples are processed. The liquid chromatography detection system was easily set up; however, the elution profile may require slight modifications. The procedures could clearly differentiate between violative (> Rm) and nonviolative (< Rm) ceftiofur residues. Participating laboratories found the procedures suitable for ceftiofur residue determination.
Zheng, Zhi; Luo, Yuling; McMaster, Gary K
2006-07-01
Accurate and precise quantification of mRNA in whole blood is made difficult by gene expression changes during blood processing, and by variations and biases introduced by sample preparations. We sought to develop a quantitative whole-blood mRNA assay that eliminates blood purification, RNA isolation, reverse transcription, and target amplification while providing high-quality data in an easy assay format. We performed single- and multiplex gene expression analysis with multiple hybridization probes to capture mRNA directly from blood lysate and used branched DNA to amplify the signal. The 96-well plate singleplex assay uses chemiluminescence detection, and the multiplex assay combines Luminex-encoded beads with fluorescent detection. The single- and multiplex assays could quantitatively measure as few as 6000 and 24,000 mRNA target molecules (0.01 and 0.04 amoles), respectively, in up to 25 microL of whole blood. Both formats had CVs < 10% and dynamic ranges of 3-4 logs. Assay sensitivities allowed quantitative measurement of gene expression in the minority of cells in whole blood. The signals from whole-blood lysate correlated well with signals from purified RNA of the same sample, and absolute mRNA quantification results from the assay were similar to those obtained by quantitative reverse transcription-PCR. Both single- and multiplex assay formats were compatible with common anticoagulants and PAXgene-treated samples; however, PAXgene preparations induced expression of known antiapoptotic genes in whole blood. Both the singleplex and the multiplex branched DNA assays can quantitatively measure mRNA expression directly from small volumes of whole blood. The assay offers an alternative to current technologies that depend on RNA isolation and is amenable to high-throughput gene expression analysis of whole blood.
NASA Astrophysics Data System (ADS)
Ray, Aniruddha; Ho, Ha; Daloglu, Mustafa; Torres, Avee; McLeod, Euan; Ozcan, Aydogan
2017-03-01
Herpes is one of the most widespread sexually transmitted viral diseases. Timely detection of Herpes Simplex Virus (HSV) can help prevent the rampant spreading of the virus. Current detection techniques such as viral culture, immuno-assays or Polymerase-Chain-Reaction, are time extensive and require expert handling. Here we present a field-portable, easy-to-use, and cost-effective biosensor for the detection of HSV based on holographic imaging. The virus is first captured from a target solution onto specifically developed substrates, prepared by coating glass coverslips with HSV-specific antibodies, and imaged using a lensfree holographic microscope. Several light-emitting-diodes (LEDs), coupled to multi-mode optical-fibers, are used to illuminate the sample containing the viruses. A micro-controller is used to activate the LEDs one at a time and in-line holograms are recorded using a CMOS imager placed immediately above the substrate. These sub-pixel shifted holograms are used to generate a super-resolved hologram, which is reconstructed to obtain the phase and amplitude images of the viruses. The signal of the viruses is enhanced using self-assembled PEG-based nanolenses, formed around the viral particles. Based on the phase information of the reconstructed images we can estimate the size of the viral particles, with an accuracy of +/- 11 nm, as well as quantify the viral load. The limit-of-detection of this system is estimated to be <500 viral copies per 100 μL sample volume that is imaged over 30 mm^2 field-of-view. This holographic microscopy based biosensor is label-free, cost-effective and field-portable, providing results in 2 hours, including sample preparation and imaging time.
Extending the frontiers of mass spectrometric instrumentation and methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schieffer, Gregg Martin
2010-01-01
The focus of this dissertation is two-fold: developing novel analysis methods using mass spectrometry and the implementation and characterization of a novel ion mobility mass spectrometry instrumentation. The novel mass spectrometry combines ion trap for ion/ion reactions coupled to an ion mobility cell. The long term goal of this instrumentation is to use ion/ion reactions to probe the structure of gas phase biomolecule ions. The three ion source - ion trap - ion mobility - qTOF mass spectrometer (IT - IM - TOF MS) instrument is described. The analysis of the degradation products in coal (Chapter 2) and the imagingmore » plant metabolites (Appendix III) fall under the methods development category. These projects use existing commercial instrumentation (JEOL AccuTOF MS and Thermo Finnigan LCQ IT, respectively) for the mass analysis of the degraded coal products and the plant metabolites, respectively. The coal degradation paper discusses the use of the DART ion source for fast and easy sample analysis. The sample preparation consisted of a simple 50 fold dilution of the soluble coal products in water and placing the liquid in front of the heated gas stream. This is the first time the DART ion source has been used for analysis of coal. Steven Raders under the guidance of John Verkade came up with the coal degradation projects. Raders performed the coal degradation reactions, worked up the products, and sent them to me. Gregg Schieffer developed the method and wrote the paper demonstrating the use of the DART ion source for the fast and easy sample analysis. The plant metabolite imaging project extends the use of colloidal graphite as a sample coating for atmospheric pressure LDI. DC Perdian and I closely worked together to make this project work. Perdian focused on building the LDI setup whereas Schieffer focused on the MSn analysis of the metabolites. Both Perdian and I took the data featured in the paper. Perdian was the primary writer of the paper and used it as a chapter in his dissertation. Perdian and Schieffer worked together to address the revisions and publish it in Rapid Communications in Mass Spectrometry Journal.« less
The Relation between easyCBM and Smarter Balanced Reading and Mathematics Assessments
ERIC Educational Resources Information Center
Alonzo, Julie
2016-01-01
This study investigated the relation between the easyCBM Benchmark Assessments in both mathematics and reading and the Smarter Balanced assessment, widely adopted across the United States. Data for the study were obtained from a convenience sample of approximately 1,000 students per grade in grades 3-8 provided by two school districts in the…
Rapid prototyping of an adaptive light-source for mobile manipulators with EasyKit and EasyLab
NASA Astrophysics Data System (ADS)
Wojtczyk, Martin; Barner, Simon; Geisinger, Michael; Knoll, Alois
2008-08-01
While still not common in day-to-day business, mobile robot platforms form a growing market in robotics. Mobile platforms equipped with a manipulator for increased flexibility have been used successfully in biotech laboratories for sample management as shown on the well-known ESACT meetings. Navigation and object recognition is carried out by the utilization of a mounted machine vision camera. To cope with the different illumination conditions in a large laboratory, development of an adaptive light source was indispensable. We present our approach of rapid developing a computer controlled, adaptive LED light within one single business day, by utilizing the hardware toolbox EasyKit and our appropriate software counterpart EasyLab.
NASA Astrophysics Data System (ADS)
Ren, Yong; Wang, Jian-Bo; Liu, Qing-Fang; Han, Xiang-Hua; Xue, De-Sheng
2009-08-01
Ordered Co/Cu multilayer nanowire arrays have been fabricated into anodic aluminium oxide templates with Ag and Cu substrate by direct current electrodeposition. This paper studies the morphology, structure and magnetic properties by transmission electron microscopy, selective area electron diffraction, x-ray diffraction, and vibrating sample magnetometer. X-ray diffraction patterns reveal that both as-deposited nanowire arrays films exhibit face-centred cubic structure. Magnetic measurements indicate that the easy magnetization direction of Co/Cu multilayer nanowire arrays films on Ag substrate is perpendicular to the long axis of nanowire, whereas the easy magnetization direction of the sample with Cu substrate is parallel to the long axis of nanowire. The change of easy magnetization direction attributed to different substrates, and the magnetic properties of the nanowire arrays are discussed.
Ahn, Sejin; Son, Tae Hwa; Cho, Ara; Gwak, Jihye; Yun, Jae Ho; Shin, Keeshik; Ahn, Seoung Kyu; Park, Sang Hyun; Yoon, Kyunghoon
2012-09-01
A simple direct solution coating process for forming CuInSe₂ (CIS) thin films was described, employing a low-cost and environmentally friendly precursor solution. The precursor solution was prepared by mixing metal acetates, ethanol, and ethanolamine. The facile formation of a precursor solution without the need to prefabricate nanoparticles enables a rapid and easy processing, and the high stability of the solution in air further ensures the precursor preparation and the film deposition in ambient conditions without a glove box. The thin film solar cell fabricated with the absorber film prepared by this route showed an initial conversion efficiency of as high as 7.72 %. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ferromagnetism of Fe 3Sn and alloys
Sales, Brian C.; Saparov, Bayrammurad; McGuire, Michael A.; ...
2014-11-12
Hexagonal Fe 3Sn has many of the desirable properties for a new permanent magnet phase with a Curie temperature of 725 K, a saturation moment of 1.18 MA/m. and anisotropy energy, K 1 of 1.8 MJ/m 3. However, contrary to earlier experimental reports, we found both experimentally and theoretically that the easy magnetic axis lies in the hexagonal plane, which is undesirable for a permanent magnet material. One possibility for changing the easy axis direction is through alloying. We used first principles calculations to investigate the effect of elemental substitutions. The calculations showed that substitution on the Sn site hasmore » the potential to switch the easy axis direction. Transition metal substitutions with Co or Mn do not have this effect. We attempted synthesis of a number of these alloys and found results in accord with the theoretical predictions for those that were formed. However, the alloys that could be readily made all showed an in-plane easy axis. The electronic structure of Fe 3Sn is reported, as are some are magnetic and structural properties for the Fe 3Sn 2, and Fe 5Sn 3 compounds, which could be prepared as mm-sized single crystals.« less
Chemical plating method of preparing radiation source material
Smith, P.K.; Huntoon, R.T.; Mosley, W.C. Jr.
1973-12-11
A uniform dispersion of a radioisotope within a noble metal matrix is provided by chemically plating a noble metal coating onto particles including a dissociable compound of the mdioisotope. A suspension of the dissociable compound in a chemically reductive solution is prepared and noble metal cations added to produce the noble metal coatings. The coated particles are filtered, dried and heated to calcine the dissociable compound to a refractory powder. The powder can be encapsulated in measured portions or consolidated and shaped into an elongated form for easy apportionnnent as radiation source material. (Official Gazette)
Ncm, a Photolabile Group for Preparation of Caged Molecules: Synthesis and Biological Application
Muralidharan, Sukumaran; Dirda, Nathaniel D. A.; Katz, Elizabeth J.; Tang, Cha-Min; Bandyopadhyay, Sharba; Kanold, Patrick O.
2016-01-01
Ncm, 6-nitrocoumarin-7-ylmethyl, is a photolabile protective group useful for making “caged” molecules. Ncm marries the reliable photochemistry of 2-nitrobenzyl systems with the excellent stability and spectroscopic properties of the coumarin chromophore. From simple, commercially available starting materials, preparation of Ncm and its caged derivatives is both quick and easy. Photorelease of Ncm-caged molecules occurs on the microsecond time scale, with quantum efficiencies of 0.05–0.08. We report the synthesis and physical properties of Ncm and its caged derivatives. The utility of Ncm-caged glutamate for neuronal photostimulation is demonstrated in cultured hippocampal neurons and in brain slice preparations. PMID:27695074
NASA Astrophysics Data System (ADS)
Borade, Ravikumar M.; Shinde, Pavan R.; Kale, Swati B.; Pawar, Rajendra P.
2018-05-01
A highly efficient magnetically recoverable cobalt ferrite nano-catalyst was prepared by sol-gel autocombustion method using glycine as green fuel. The prepared material has been characterized by X-ray powder diffraction and scanning. An investigation of its catalytic activity showed it to be a heterogeneous Lewis acid catalyst for the synthesis of substituted benzimidazoles. The aqueous ethanol used as green solvent for the reaction. The nm size range of these particles facilitates the catalysis process, as an increased surface area available for the reaction. The easy separation of the catalyst by an external magnet and their recovery and reuse in next cycle reaction are additional benefits.
NASA Astrophysics Data System (ADS)
Guan, Yebin; Shi, Juanjuan; Xia, Ming; Zhang, Jun; Pang, Zhenfeng; Marchetti, Alessandro; Wang, Xiaohong; Cai, Jingsong; Kong, Xueqian
2017-11-01
Monodispersed zeolitic imidazolate frameworks (ZIFs) were prepared with a simple method using dimethylsulfoxide (DMSO) as solvent. This method yields ZIF-8 nanoparticles with a narrow particle size distribution of 90-110 nm and the dispersion is highly stable against agglomeration. These particles have larger nanosized porosity and enhanced CO2 adsorption capability compared to ZIF-8 prepared with different solvents such as methanol or N, N-dimethyl formamide. Their uniform size and surface chemistry also lead to superior performance in the Knoevenagel condensation reactions. The ZIF-8 nanoparticles possess high thermal stability up to 550 °C and the preparation steps are easy for scaling up which are favorable for industrial applications.
Nizame, Fosiul A.; Leontsini, Elli; Luby, Stephen P.; Nuruzzaman, Md.; Parveen, Shahana; Winch, Peter J.; Ram, Pavani K.; Unicomb, Leanne
2016-01-01
This study explored the steps of food preparation, related handwashing opportunities, current practices, and community perceptions regarding foods at high-risk of contamination such as mashed foods and salads. In three rural Bangladeshi villages, we collected qualitative and observational data. Food preparation was a complex and multistep process. Food preparation was interrupted by tasks that could contaminate the preparers' hands, after which they continued food preparation without washing hands. Community members typically ate hand-mixed, uncooked mashed food and salad as accompaniments to curry and rice at meals. Hand-mixed dried foods were mostly consumed as a snack. Observers recorded handwashing during preparation of these foods. Among 24 observed caregivers, of 85 opportunities to wash hands with soap during food preparation, washing hands with soap occurred twice, both times after cutting fish, whereas washing hands with water alone was common. A simple and feasible approach is promotion of handwashing with soap upon entering and re-entering the food preparation area, and ensuring that everything needed for handwashing should be within easy reach. PMID:27296388
Nizame, Fosiul A; Leontsini, Elli; Luby, Stephen P; Nuruzzaman, Md; Parveen, Shahana; Winch, Peter J; Ram, Pavani K; Unicomb, Leanne
2016-08-03
This study explored the steps of food preparation, related handwashing opportunities, current practices, and community perceptions regarding foods at high-risk of contamination such as mashed foods and salads. In three rural Bangladeshi villages, we collected qualitative and observational data. Food preparation was a complex and multistep process. Food preparation was interrupted by tasks that could contaminate the preparers' hands, after which they continued food preparation without washing hands. Community members typically ate hand-mixed, uncooked mashed food and salad as accompaniments to curry and rice at meals. Hand-mixed dried foods were mostly consumed as a snack. Observers recorded handwashing during preparation of these foods. Among 24 observed caregivers, of 85 opportunities to wash hands with soap during food preparation, washing hands with soap occurred twice, both times after cutting fish, whereas washing hands with water alone was common. A simple and feasible approach is promotion of handwashing with soap upon entering and re-entering the food preparation area, and ensuring that everything needed for handwashing should be within easy reach. © The American Society of Tropical Medicine and Hygiene.
Using Candy Samples to Learn about Sampling Techniques and Statistical Data Evaluation
ERIC Educational Resources Information Center
Canaes, Larissa S.; Brancalion, Marcel L.; Rossi, Adriana V.; Rath, Susanne
2008-01-01
A classroom exercise for undergraduate and beginning graduate students that takes about one class period is proposed and discussed. It is an easy, interesting exercise that demonstrates important aspects of sampling techniques (sample amount, particle size, and the representativeness of the sample in relation to the bulk material). The exercise…
Information Repetition in Evaluative Judgments: Easy to Monitor, Hard to Control
ERIC Educational Resources Information Center
Unkelbach, Christian; Fiedler, Klaus; Freytag, Peter
2007-01-01
The sampling approach [Fiedler, K. (2000a). "Beware of samples! A cognitive-ecological sampling approach to judgment biases." "Psychological Review, 107"(4), 659-676.] attributes judgment biases to the information given in a sample. Because people usually do not monitor the constraints of samples and do not control their judgments accordingly,…
Sample Size Estimation: The Easy Way
ERIC Educational Resources Information Center
Weller, Susan C.
2015-01-01
This article presents a simple approach to making quick sample size estimates for basic hypothesis tests. Although there are many sources available for estimating sample sizes, methods are not often integrated across statistical tests, levels of measurement of variables, or effect sizes. A few parameters are required to estimate sample sizes and…
Introduction to Photolithography: Preparation of Microscale Polymer Silhouettes
ERIC Educational Resources Information Center
Berkowski, Kimberly L.; Plunkett, Kyle N.; Moore, Jeffrey S.
2005-01-01
A study describes an easy procedure based on a negative photoresist process designed for junior high or high school students, which will introduce them to the key terms and concepts of photolithography. The experiment allows students to visualize the fundamental process behind microchip fabrication, observe the rapid prototyping enabled by such a…
Working in the World of Children.
ERIC Educational Resources Information Center
Magyar, Susan L.; Walsky, Anne M.
This curriculum guide is designed to create a pre-vocational awareness in the area of child care for students in ninth grade. The program covers both preparation for parenthood and occupational possibilities in this field. The twenty-nine, easy-to-read lessons have been divided into the following six units: (1) child care careers; (2)…
A Dozen Teaching Tips for Diverse Classrooms
ERIC Educational Resources Information Center
Fogg, Piper
2007-01-01
For the majority of community-college professors, teaching is the most important part of their jobs, and it is not easy. Community-college students are a diverse bunch, but often face a particular set of challenges. Many entering students are not prepared for college-level work. While some students plan to transfer to competitive four-year…
ERIC Educational Resources Information Center
Smith, Robert Alan
Plant tissue culture has developed into a valid botanical discipline and is considered a key area of biotechnology, but it has not been a key component of the science curriculum because of the expensive and technical nature of research in this area. This manual presents a number of activities that are relatively easy to prepare and perform. The…
ERIC Educational Resources Information Center
Newbill, Phyllis; Baum, Liesl
2013-01-01
Technology is revolutionizing the way the world works, and there seems to be no end in sight. Information is everywhere and easy to find, so today's students will need to know what to do with it to be prepared for the overly stimulating, technology-driven, problem-riddled world they will soon face. That's why critical- and creative-thinking skills…
Drug delivery in cancer using liposomes.
Dass, Crispin R
2008-01-01
There are various types of liposomes used for cancer therapy, but these can all be placed into three distinct categories based on the surface charge of vesicles: neutral, anionic and cationic. This chapter describes the more rigorous and easy methods used for liposome manufacture, with references, to aid the reader in preparing these formulations in-house.
Making Usable, Quality Opaque or Transparent Soap
ERIC Educational Resources Information Center
Mabrouk, Suzanne T.
2005-01-01
The experiment to make opaque and transparent soap, using cold and semi boiled processes respectively, and surfactant tests that measure the pH of the prepared soap, is introduced. The experiment shows an easy method to make soap by giving a choice to select oils and scents for the soap, which can be used at home.
42 CFR 9.4 - Physical facility policies and design.
Code of Federal Regulations, 2010 CFR
2010-10-01
....edu; or view it online at http://oacu.od.nih.gov/regs/guide/guidex.htm. You may inspect a copy at NIH... required to develop disaster and escaped animal contingency plans? The sanctuary facility must prepare disaster and escaped animal contingency plans outlining simple and easy to follow plans for dealing with...
ERIC Educational Resources Information Center
Eslinger, Leslie Silk
Recognizing the long-lasting impact of young childrens learning through themes as well as the amount of teacher time spent in preparing for this type of teaching, this kit is designed to help teachers avoid the shortcomings of theme-based teaching, while capitalizing on the benefits of this approach. The book is presented in two sections. The…
The Impact of Hands-On Simulation Laboratories on Teaching of Wireless Communications
ERIC Educational Resources Information Center
Chou, Te-Shun; Vanderbye, Aaron
2017-01-01
Aim/Purpose: To prepare students with both theoretical knowledge and practical skills in the field of wireless communications. Background: Teaching wireless communications and networking is not an easy task because it involves broad subjects and abstract content. Methodology: A pedagogical method that combined lectures, labs, assignments, exams,…
Centrifugal partition chromatography a first dimension for biomass fast pyrolysis oil analysis.
Le Masle, Agnès; Santin, Sandra; Marlot, Léa; Chahen, Ludovic; Charon, Nadège
2018-10-31
Biomass fast pyrolysis oils contain molecules having a large variety of chemical functions and a wide range of molecular weights (from several tens to several thousand grams per mole). The good knowledge of their complex composition is essential for optimizing the conversion of bio-oils to biofuels, thereby requiring powerful separation techniques. In this work, we investigate the interest of centrifugal partition chromatography (CPC) as a first dimension for the analysis of a bio-oil. A CPC method is proposed to separate oxygen containing compounds according to their partition coefficients in the solvent system. This approach is a powerful and easy-to-use technique that enables fractionation of a bio-oil at a semi-preparative scale, without any sample loss related to adsorption on the stationary phase. Collected fractions are then injected in liquid chromatography as a second dimension of separation. Contour plot representations of the CPC × LC separation are established to discuss the potential of this approach. These representations can be used as a veritable fingerprint in the comparison of different samples or samples at different steps of a conversion process but also as a powerful tool to identify new compounds and describe the entire composition of the bio-oil. Copyright © 2018 Elsevier B.V. All rights reserved.
Okumura, M; Tong, L; Fujinaga, K; Seike, Y
2001-05-01
A simple and rapid in situ preconcentration method for the determination of phosphate in environmental waters has been developed for field analysis. This method is based on solid-phase extraction on a zirconium-loaded Sep-Pack Accell CM cartridge (Zr-SP) and is applicable to studies in which sampling is performed by use of a graduated syringe to prevent contamination and to ensure easy operation at sampling sites. The Zr-SP cartridge was prepared by passing 0.1 mol L(-1) zirconium solution through a Sep-Pak Accell CM cartridge, packed with cation exchange sorbent based on a silica matrix. The adsorption of phosphate and its desorption depend only on the pH of the solution. A water sample containing phosphate was adjusted to pH 2 and passed through the Zr-SP cartridge to collect it. The retained phosphate was quantitatively eluted with 0.5 mol L(-1) sodium hydroxide solution. The phosphate retained in the Zr-SP cartridge was stable for at least one month. The established preconcentration method was successfully applied to brackish lake waters to investigate seasonal changes in the distribution and behavior of phosphate in a brackish lake.
[Secondary Raman spectrum of beta-carotene molecule in living leaf of French phoenix tree].
Zhao, Jin-tao; Zhang, Peng-xiang; Xu, Cun-ying
2002-10-01
Under visible incidence light 514.5 nm, the Raman scattering spectrum from the beta-carotene molecule in the leaf was directly obtained after it was immediately collected from French phoenix tree without any preparing the sample but cleaning. It is very easy to collect the secondary Raman lines addition to the first Raman spectrum in situ by micro Raman. By careful comparing and analyzing the Raman lines between 2,000-3,100 cm-1 and below 2,000 cm-1 regions, we obtained the correlated relation of the first and secondary Raman lines. The study results indicated that there is no damage to the structure and configuration of beta-carotene molecule in the live leaf by controlling laser power on the sample surface and integrating time for Raman signal, but large power laser or long time irradiation on the live sample would cause very strong fluorescence background in Raman spectrum which indicated that there is a photo damage in the center of photo reaction. The Micro Raman would become one of possible in situ methods for investigating live plant molecules growing up in different environment. At last we proposed and discussed the advantages and limits in micro Raman when it is applied to investigating live molecules in botany field.
Porpiglia, Nadia Maria; De Palo, Elio Franco; Savchuk, Sergey Alexandrovich; Appolonova, Svetlana Alexandrovna; Bortolotti, Federica; Tagliaro, Franco
2018-05-10
The non-glycosylated glycoform of transferrin (Tf), known as asialo-Tf, was not selected (in favor of disialo-Tf) as the measurand for the standardization of carbohydrate deficient transferrin (CDT) determination because of a lower diagnostic sensitivity provided with the currently available analytical procedures for sera. However, asialo-Tf could provide an additional value to disialo-Tf in the CDT analysis employed in forensic toxicology contexts. The present work aimed at developing an easy sample preparation based on PEG precipitation in order to improve the detectability of asialo-Tf in capillary electrophoresis (CE). Equal volumes (35 μL) of serum and of 30% PEG-8000 were mixed and briefly vortexed. After centrifugation, the supernatant was iron saturated with a ferric solution (1:1, v/v). The mixture was analyzed in CE for asialo-Tf and disialo-Tf determination. PEG-8000 precipitation allowed the improvement of the baseline in the electropherograms in terms of interferences reduction particularly in the asialo-Tf migration region. The detection of asialo-Tf was possible in 89% of samples with disialo-Tf above the cut-off limit, whereas only 16% of them showed asialo-Tf by employing the traditional sample preteatment. Asialo-Tf represents an additional value to disialo-Tf as a biomarker of alcohol abuse in forensic toxicology. Copyright © 2018. Published by Elsevier B.V.
Examining the Internal Structure of the easyCBM Reading Measures, Grades K-5. Technical Report #1302
ERIC Educational Resources Information Center
Alonzo, Julie; Park, Bitnara Jasmine; Tindal, Gerald
2013-01-01
In this technical report, we describe a study examining the internal structures of the easyCBM reading measures, Grades K-5. Data were gathered from a convenience sample of 114 Kindergarten students, 43 first graders, 82 second graders, 100 third graders, 109 fourth graders, and 71 fifth graders attending schools in Oregon, Georgia, South…
The Alignment of easyCBM[R] Math Measures to Curriculum Standards. Technical Report #1002
ERIC Educational Resources Information Center
Nese, Joseph F. T.; Lai, Cheng-Fei; Anderson, Daniel; Park, Bitnara Jasmine; Tindal, Gerald; Alonzo, Julie
2010-01-01
The purpose of this study was to examine the alignment of the easyCBM[R] mathematics benchmark and progress monitoring measures to the National Council of Teachers of Mathematics "Curriculum Focal Points" (NCTM, 2006). Based on Webb's alignment model (1997, 2002), we collected expert judgments on individual math items across a sampling of forms…
Kim, Sung-Gun; Yoo, Byoungseung
2015-01-01
Although extensive literature is available on the viscosity of thickened beverages with food thickeners, no attempt has been made to study the effect of setting time on the viscosity of pudding-like cold-thickened beverages with xanthan gum (XG)-based thickeners by using a rheometer. In particular, it is of considerable practical importance to investigate the effect of setting time on their viscosity at 5°C because some cold-thickened beverages will be prepared in the kitchen in bulk and stored at 5°C before serving or consuming rather than serving immediately upon mixing with thickeners. To examine the effect of different setting times (15-120 min) on the viscosity of cold-thickened beverages prepared with various XG-based food thickeners, and also to compare the viscosity differences among the various cold beverages and XG-based food thickeners in beverage-thickener mixture systems. Four commercially available XG-based food thickeners (A-D) and three cold beverages (water, orange juice and milk) were used for the preparation of cold-thickened beverages. The thickened sample was portioned into six samples for the designated setting times and then stored at 5°C over setting time. Their apparent viscosity (η(a,50)) at 50 s(-1) was measured using a rheometer. The largest increases in η(a,50) values for thickened beverages, except for water, were observed at 15 min (p < 0.05), showing a pudding-like fluid, and at longer time periods their η(a,50) values gradually increased or were constant with an increase in setting time. The percentage increase in viscosity values at different setting times (15-120 min) as compared with the control (0 min) was less pronounced in the thickened orange juice and milk samples with thickener A over setting time, indicating that the thickened beverages with thickener A had more stable structure compared with those with other thickeners (B-D) over time. Statistical analysis showed that changes in the viscosity of cold-thickened beverages over setting time are greatly influenced by the type of beverages and thickeners. Cold-thickened beverages should be carefully prepared with instant commercial XG-based food thickeners because they produced different thickening patterns over setting time which clinicians must consider for a safe and easy swallowing. The information presented in this study will provide both clinicians and patients with additional knowledge to prepare cold-thickened beverages with the corrected viscosity for safe swallowing. © 2014 Royal College of Speech and Language Therapists.
Sudore, Rebecca L; Barnes, Deborah E; Le, Gem M; Ramos, Roberto; Osua, Stacy J; Richardson, Sarah A; Boscardin, John; Schillinger, Dean
2016-01-01
Introduction Advance care planning (ACP) is a process that allows patients to identify their goals for medical care. Traditionally, ACP has focused on completing advance directives; however, we have expanded the ACP paradigm to also prepare patients to communicate their wishes and make informed decisions. To this end, we created an ACP website called PREPARE (http://www.prepareforyourcare.org) to prepare diverse English-speaking and Spanish-speaking older adults for medical decision-making. Here, we describe the study protocol for a randomised controlled efficacy trial of PREPARE in a safety-net setting. The goal is to determine the efficacy of PREPARE to engage diverse English-speaking and Spanish-speaking older adults in a full spectrum of ACP behaviours. Methods and analysis We include English-speaking and Spanish-speaking adults from an urban public hospital who are ≥55 years old, have ≥2 chronic medical conditions and have seen a primary care physician ≥2 times in the last year. Participants are randomised to the PREPARE intervention (review PREPARE and an easy-to-read advance directive) or the control arm (only the easy-to-read advance directive). The primary outcome is documentation of an advance directive and/or ACP discussion. Secondary outcomes include ACP behaviour change processes measured with validated surveys (eg, self-efficacy, readiness) and a broad range of ACP actions (eg, choosing a surrogate, identifying goals for care, discussing ACP with clinicians and/or surrogates). Using blinded outcome ascertainment, outcomes will be measured at 1 week and at 3, 6 and 12 months, and compared between study arms using mixed-effects logistic regression and mixed-effects linear, Poisson or negative binomial regression. Ethics and dissemination This study has been approved by the appropriate Institutional Review Boards and is guided by input from patient and clinical advisory boards and a data safety monitoring board. The results of this study will be disseminated to academic and community stakeholders. Trial registration numbers NCT01990235; NCT02072941; Pre-results. PMID:27401363
Sudore, Rebecca L; Barnes, Deborah E; Le, Gem M; Ramos, Roberto; Osua, Stacy J; Richardson, Sarah A; Boscardin, John; Schillinger, Dean
2016-07-11
Advance care planning (ACP) is a process that allows patients to identify their goals for medical care. Traditionally, ACP has focused on completing advance directives; however, we have expanded the ACP paradigm to also prepare patients to communicate their wishes and make informed decisions. To this end, we created an ACP website called PREPARE (http://www.prepareforyourcare.org) to prepare diverse English-speaking and Spanish-speaking older adults for medical decision-making. Here, we describe the study protocol for a randomised controlled efficacy trial of PREPARE in a safety-net setting. The goal is to determine the efficacy of PREPARE to engage diverse English-speaking and Spanish-speaking older adults in a full spectrum of ACP behaviours. We include English-speaking and Spanish-speaking adults from an urban public hospital who are ≥55 years old, have ≥2 chronic medical conditions and have seen a primary care physician ≥2 times in the last year. Participants are randomised to the PREPARE intervention (review PREPARE and an easy-to-read advance directive) or the control arm (only the easy-to-read advance directive). The primary outcome is documentation of an advance directive and/or ACP discussion. Secondary outcomes include ACP behaviour change processes measured with validated surveys (eg, self-efficacy, readiness) and a broad range of ACP actions (eg, choosing a surrogate, identifying goals for care, discussing ACP with clinicians and/or surrogates). Using blinded outcome ascertainment, outcomes will be measured at 1 week and at 3, 6 and 12 months, and compared between study arms using mixed-effects logistic regression and mixed-effects linear, Poisson or negative binomial regression. This study has been approved by the appropriate Institutional Review Boards and is guided by input from patient and clinical advisory boards and a data safety monitoring board. The results of this study will be disseminated to academic and community stakeholders. NCT01990235; NCT02072941; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Compounded Apixaban Suspensions for Enteral Feeding Tubes.
Caraballo, Maria L; Donmez, Seda; Nathan, Kobi; Zhao, Fang
2017-07-01
Objective: There is limited information on compounded apixaban formulations for administration via enteral feeding tubes. This study was designed to identify a suitable apixaban suspension formulation that is easy to prepare in a pharmacy setting, is compatible with commonly used feeding tubes, and has a beyond-use date of 7 days. Methods: Apixaban suspensions were prepared from commercially available 5-mg Eliquis tablets. Several vehicles and compounding methods were screened for ease of preparation, dosage accuracy, and tube compatibility. Two tubing types, polyurethane and polyvinyl chloride, with varying lengths and diameters, were included in the study. They were mounted on a peg board during evaluation to mimic the patient body position. A 7-day stability study of the selected formulation was also conducted. Results: Vehicles containing 40% to 60% Ora-Plus in water all exhibited satisfactory flowability through the tubes. The mortar/pestle compounding method was found to produce more accurate and consistent apixaban suspensions than the pill crusher or crushing syringe method. The selected formulation, 0.25 mg/mL apixaban in 50:50 Ora-Plus:water, was compatible with both tubing types, retaining >98% drug in posttube samples. The stability study also confirmed that this formulation was stable physically and chemically over 7 days of storage at room temperature. Conclusions: A suitable apixaban suspension formulation was identified for administration via enteral feeding tubes. The formulation consisted of 0.25 mg/mL apixaban in 50:50 Ora-Plus:water. The stability study results supported a beyond-use date of 7 days at room temperature.
Eberl, D.D.
2003-01-01
RockJock is a computer program that determines quantitative mineralogy in powdered samples by comparing the integrated X-ray diffraction (XRD) intensities of individual minerals in complex mixtures to the intensities of an internal standard. Analysis without an internal standard (standardless analysis) also is an option. This manual discusses how to prepare and X-ray samples and mineral standards for these types of analyses and describes the operation of the program. Carefully weighed samples containing an internal standard (zincite) are ground in a McCrone mill. Randomly oriented preparations then are X-rayed, and the X-ray data are entered into the RockJock program. Minerals likely to be present in the sample are chosen from a list of standards, and the calculation is begun. The program then automatically fits the sum of stored XRD patterns of pure standard minerals (the calculated pattern) to the measured pattern by varying the fraction of each mineral standard pattern, using the Solver function in Microsoft Excel to minimize a degree of fit parameter between the calculated and measured pattern. The calculation analyzes the pattern (usually 20 to 65 degrees two-theta) to find integrated intensities for the minerals. Integrated intensities for each mineral then are determined from the proportion of each mineral standard pattern required to give the best fit. These integrated intensities then are compared to the integrated intensity of the internal standard, and the weight percentages of the minerals are calculated. The results are presented as a list of minerals with their corresponding weight percent. To some extent, the quality of the analysis can be checked because each mineral is analyzed independently, and, therefore, the sum of the analysis should approach 100 percent. Also, the method has been shown to give good results with artificial mixtures. The program is easy to use, but does require an understanding of mineralogy, of X-ray diffraction practice, and an elementary knowledge of the Excel program.
Vignaduzzo, Silvana E; Maggio, Rubén M; Castellano, Patricia M; Kaufman, Teodoro S
2006-12-01
Two new analytical methods have been developed as convenient and useful alternatives for simultaneous determination of hydrochlorothiazide (HCT) and propranolol hydrochloride (PRO) in pharmaceutical formulations. The methods are based on the first derivative of ratio spectra (DRS) and on partial least squares (PLS) analysis of the ultraviolet absorption spectra of the samples in the 250-350-nm region. The methods were calibrated between 8.7 and 16.0 mg L(-1) for HCT and between 14.0 and 51.5 mg L(-1) for PRO. An asymmetric full-factorial design and wavelength selection (277-294 nm for HCT and 297-319 for PRO) were used for the PLS method and signal intensities at 276 and 322 nm were used in the DRS method for HCT and PRO, respectively. Performance characteristics of the analytical methods were evaluated by use of validation samples and both methods showed to be accurate and precise, furnishing near quantitative analyte recoveries (100.4 and 99.3% for HCT and PRO by use of PLS) and relative standard deviations below 2%. For PLS the lower limits of quantification were 0.37 and 0.66 mg L(-1) for HCT and PRO, respectively, whereas for DRS they were 1.15 and 3.05 mg L(-1) for HCT and PRO, respectively. The methods were used for quantification of HCT and PRO in synthetic mixtures and in two commercial tablet preparations containing different proportions of the analytes. The results of the drug content assay and the tablet dissolution test were in statistical agreement (p < 0.05) with those furnished by the official procedures of the USP 29. Preparation of dissolution profiles of the combined tablet formulations was also performed with the aid of the proposed methods. The methods are easy to apply, use relatively simple equipment, require minimum sample pre-treatment, enable high sample throughput, and generate less solvent waste than other procedures.
Eslamizad, Samira; Yazdanpanah, Hassan; Javidnia, Katayon; Sadeghi, Ramezan; Bayat, Mitra; Shahabipour, Sara; Khalighian, Najmeh; Kobarfard, Farzad
2016-01-01
A fast and simple modified QuEChERS (quick, easy, cheap, rugged and safe) extraction method based on spiked calibration curves and direct sample introduction was developed for determination of Benzo [a] pyrene (BaP) in bread by gas chromatography-mass spectrometry single quadrupole selected ion monitoring (GC/MS-SQ-SIM). Sample preparation includes: extraction of BaP into acetone followed by cleanup with dispersive solid phase extraction. The use of spiked samples for constructing the calibration curve substantially reduced adverse matrix-related effects. The average recovery of BaP at 6 concentration levels was in range of 95-120%. The method was proved to be reproducible with relative standard deviation less than 14.5% for all of the concentration levels. The limit of detection and limit of quantification were 0.3 ng/g and 0.5 ng/g, respectively. Correlation coefficient of 0.997 was obtained for spiked calibration standards over the concentration range of 0.5-20 ng/g. To the best of our knowledge, this is the first time that a QuEChERS method is used for the analysis of BaP in breads. The developed method was used for determination of BaP in 29 traditional (Sangak) and industrial (Senan) bread samples collected from Tehran in 2014. These results showed that two Sangak samples were contaminated with BaP. Therefore, a comprehensive survey for monitoring of BaP in Sangak bread samples seems to be needed. This is the first report concerning contamination of bread samples with BaP in Iran. PMID:27642317
Arul, P; Eniya, S; Pushparaj, Magesh; Masilamani, Suresh; Kanmani, P; Lingasamy, C
2018-01-01
Conventional Papanicolaou (Pap) stain has undergone many modifications; of these, ultrafast Pap stain is the most popular as it shortens the turnaround time of reporting. Application of modified ultrafast Pap (MUFP) stain in the evaluation of fine needle aspiration (FNA) samples and body fluids are scanty. To evaluate the utility of MUFP stain in various FNA samples and body fluids and compare the findings with those of conventional Pap stain. In this cross-sectional study, two wet-fixed and two airdried smears from each sample [301 samples (255 FNA samples and 46 body fluids)] were prepared and stained by the conventional Pap and MUFP stains, respectively. Concordant and discordant rate was calculated. Quality index (QI) of MUFP stain was assessed by background, overall staining, cell morphology, and nuclear characteristics. MUFP-stained smears were also categorized into excellent, good, and fair. The concordance rate for MUFP stain was 100%. QI of MUFP stain for breast, thyroid, lymph node, soft tissue, salivary gland, and body fluids was 0.9, 0.93, 0.95, 1, 0.94, and 1, respectively. Excellent quality of stain was noted in 53.2% and good in 24.6% of the cases allowing easy diagnosis. In 22.2% of fair cases, diagnosis was possible with some difficulties. Our study concluded that MUFP stain could be considered as a rapid and reliable diagnostic tool and can be applied on a regular basis in FNA samples and body fluids to offer immediate diagnosis. However, caution should be taken while reporting certain MUFP-stained smears to avoid over/under diagnosis.
Schmalreck, Arno; Willinger, Birgit; Czaika, Viktor; Fegeler, Wolfgang; Becker, Karsten; Blum, Gerhard; Lass-Flörl, Cornelia
2012-12-01
In vitro susceptibility testing of clinically important fungi becomes more and more essential due to the rising number of fungal infections in patients with impaired immune system. Existing standardized microbroth dilution methods for in vitro testing of molds (CLSI, EUCAST) are not intended for routine testing. These methods are very time-consuming and dependent on sporulating of hyphomycetes. In this multicentre study, a new (independent of sporulation) inoculum preparation method (containing a mixture of vegetative cells, hyphae, and conidia) was evaluated. Minimal inhibitory concentrations (MIC) of amphotericin B, posaconazole, and voriconazole of 180 molds were determined with two different culture media (YST and RPMI 1640) according to the DIN (Deutsches Institut für Normung) microdilution assay. 24 and 48 h MIC of quality control strains, tested per each test run, prepared with the new inoculum method were in the range of DIN. YST and RPMI 1640 media showed similar MIC distributions for all molds tested. MIC readings at 48 versus 24 h yield 1 log(2) higher MIC values and more than 90 % of the MICs read at 24 and 48 h were within ± 2 log(2) dilution. MIC end point reading (log(2 MIC-RPMI 1640)-log(2 MIC-YST)) of both media demonstrated a tendency to slightly lower MICs with RPMI 1640 medium. This study reports the results of a new, time-saving, and easy-to-perform method for inoculum preparation for routine susceptibility testing that can be applied for all types of spore-/non-spore and hyphae-forming fungi.
Sudore, Rebecca; Le, Gem M; McMahan, Ryan; McMahon, Ryan; Feuz, Mariko; Katen, Mary; Barnes, Deborah E
2015-12-12
Advance care planning (ACP) is a process whereby patients prepare for medical decision-making. The traditional objective of ACP has focused on the completion of advance directives. We have developed a new paradigm of ACP focused on preparing patients and their loved ones for communication and informed medical decision-making. To operationalize this new paradigm of ACP, we created an interactive, patient-centered website called PREPARE ( www.prepareforyourcare.org ) designed for diverse older adults. This randomized controlled trial with blinded outcome assessment is designed to determine the efficacy of PREPARE to engage older Veterans in the ACP process. Veterans who are ≥ 60 years of age, have ≥ two medical conditions, and have seen a primary care physician ≥ two times in the last year are being randomized to one of two study arms. The PREPARE study arm reviews the PREPARE website and an easy-to-read advance directive. The control arm only reviews the advance directive. The primary outcome is documentation of an advance directive and ACP discussions. Other clinically important outcomes using validated surveys include ACP behavior change process measures (knowledge, contemplation, self-efficacy, and readiness) and a full range of ACP action measures (identifying a surrogate, identifying values and goals, choosing leeway or flexibility for the surrogate, communicating with clinicians and surrogates, and documenting one's wishes). We will also assess satisfaction with decision-making and Veteran activation within primary care visits by direct audio recording. To examine the outcomes at 1 week, 3 months, and 6 months between the two study arms, we will use mixed effects linear, Poisson, or negative binomial regression and mixed effects logistic regression. This study will determine whether PREPARE increases advance directive completion rates and engagement with the ACP process. If PREPARE is efficacious, it could prove to be an easy and effective intervention to help older adults engage in the ACP process within or outside of the medical environment. PREPARE may also help older adults communicate their medical wishes and goals to their loved ones and clinicians, improve medical decision-making, and ensure their wishes are honored over the life course. ClinicalTrials.gov NCT01550731 . Registered on 8 December 2011.
NASA Astrophysics Data System (ADS)
Zhang, Shenghuan; Gai, Shili; He, Fei; Ding, Shujiang; Li, Lei; Yang, Piaoping
2014-09-01
The easy aggregation nature of ferromagnetic nanoparticles (NPs) prepared by conventional routes usually leads to a large particle size and low loading, which greatly limits their applications to the reduction of 4-nitrophenol (4-NP). Herein, we developed a novel in situ thermal decomposition and reduction strategy to prepare Ni nanoparticles/silica nanotubes (Ni/SNTs), which can markedly prevent the aggregation and growth of Ni NPs, resulting in an ultra-small particle size (about 6 nm), good dispersion and especially high loading of Ni NPs. It was found that Ni/SNTs, which have a high specific surface area (416 m2 g-1), exhibit ultra-high catalytic activity in the 4-NP reduction (complete reduction of 4-NP within only 60 s at room temperature), which is superior to most noble metal (Au, Pt, and Pd) supported catalysts. Ni/SNTs still showed high activity even after re-use for several cycles, suggesting good stability. In particular, the magnetic property of Ni/SNTs makes it easy to recycle for reuse.The easy aggregation nature of ferromagnetic nanoparticles (NPs) prepared by conventional routes usually leads to a large particle size and low loading, which greatly limits their applications to the reduction of 4-nitrophenol (4-NP). Herein, we developed a novel in situ thermal decomposition and reduction strategy to prepare Ni nanoparticles/silica nanotubes (Ni/SNTs), which can markedly prevent the aggregation and growth of Ni NPs, resulting in an ultra-small particle size (about 6 nm), good dispersion and especially high loading of Ni NPs. It was found that Ni/SNTs, which have a high specific surface area (416 m2 g-1), exhibit ultra-high catalytic activity in the 4-NP reduction (complete reduction of 4-NP within only 60 s at room temperature), which is superior to most noble metal (Au, Pt, and Pd) supported catalysts. Ni/SNTs still showed high activity even after re-use for several cycles, suggesting good stability. In particular, the magnetic property of Ni/SNTs makes it easy to recycle for reuse. Electronic supplementary information (ESI) available: XRD pattern and TEM image of SNTs after calcination, XRD pattern and EDS of NiSNTs, SEM images of a single SNT, NiSNTs and Ni/SNTs, enlarged HRTEM of Ni/SNTs, XRD pattern of NiO/SNTs, UV-vis spectra of the catalytic reduction of 4-NP to 4-AP over Ni/SNTs with different loading amounts, Ni/SNTs synthesized by wet impregnation and Ni/CNTs, TEM images of Ni/SNTs synthesized by wet impregnation and Ni/CNTs. See DOI: 10.1039/c4nr02096k
NASA Technical Reports Server (NTRS)
Shiller, Alan M.
2003-01-01
It is well-established that sampling and sample processing can easily introduce contamination into dissolved trace element samples if precautions are not taken. However, work in remote locations sometimes precludes bringing bulky clean lab equipment into the field and likewise may make timely transport of samples to the lab for processing impossible. Straightforward syringe filtration methods are described here for collecting small quantities (15 mL) of 0.45- and 0.02-microm filtered river water in an uncontaminated manner. These filtration methods take advantage of recent advances in analytical capabilities that require only small amounts of waterfor analysis of a suite of dissolved trace elements. Filter clogging and solute rejection artifacts appear to be minimal, although some adsorption of metals and organics does affect the first approximately 10 mL of water passing through the filters. Overall the methods are clean, easy to use, and provide reproducible representations of the dissolved and colloidal fractions of trace elements in river waters. Furthermore, sample processing materials can be prepared well in advance in a clean lab and transported cleanly and compactly to the field. Application of these methods is illustrated with data from remote locations in the Rocky Mountains and along the Yukon River. Evidence from field flow fractionation suggests that the 0.02-microm filters may provide a practical cutoff to distinguish metals associated with small inorganic and organic complexes from those associated with silicate and oxide colloids.
Chen, Xiaowen; Zhao, Luqian; Qin, Hongran; Zhao, Meijia; Zhou, Yirui; Yang, Shuqiang; Su, Xu; Xu, Xiaohua
2014-05-01
The aim of this work was to develop a method to provide rapid results for humans with internal radioactive contamination. The authors hypothesized that valuable information could be obtained from gas proportional counter techniques by screening urine samples from potentially exposed individuals rapidly. Recommended gross alpha and beta activity screening methods generally employ gas proportional counting techniques. Based on International Standards Organization (ISO) methods, improvements were made in the evaporation process to develop a method to provide rapid results, adequate sensitivity, and minimum sample preparation and operator intervention for humans with internal radioactive contamination. The method described by an American National Standards Institute publication was used to calibrate the gas proportional counter, and urine samples from patients with or without radionuclide treatment were measured to validate the method. By improving the evaporation process, the time required to perform the assay was reduced dramatically. Compared with the reference data, the results of the validation samples were very satisfactory with respect to gross-alpha and gross-beta activities. The gas flow proportional counting method described here has the potential for radioactivity monitoring in the body. This method was easy, efficient, and fast, and its application is of great utility in determining whether a sample should be analyzed by a more complicated method, for example radiochemical and/or γ-spectroscopy. In the future, it may be used commonly in medical examination and nuclear emergency treatment.Health Phys. 106(5):000-000; 2014.
Easy preparation of a large-size random gene mutagenesis library in Escherichia coli.
You, Chun; Percival Zhang, Y-H
2012-09-01
A simple and fast protocol for the preparation of a large-size mutant library for directed evolution in Escherichia coli was developed based on the DNA multimers generated by prolonged overlap extension polymerase chain reaction (POE-PCR). This protocol comprised the following: (i) a linear DNA mutant library was generated by error-prone PCR or shuffling, and a linear vector backbone was prepared by regular PCR; (ii) the DNA multimers were generated based on these two DNA templates by POE-PCR; and (iii) the one restriction enzyme-digested DNA multimers were ligated to circular plasmids, followed by transformation to E. coli. Because the ligation efficiency of one DNA fragment was several orders of magnitude higher than that of two DNA fragments for typical mutant library construction, it was very easy to generate a mutant library with a size of more than 10(7) protein mutants per 50 μl of the POE-PCR product. Via this method, four new fluorescent protein mutants were obtained based on monomeric cherry fluorescent protein. This new protocol was simple and fast because it did not require labor-intensive optimizations in restriction enzyme digestion and ligation, did not involve special plasmid design, and enabled constructing a large-size mutant library for directed enzyme evolution within 1 day. Copyright © 2012 Elsevier Inc. All rights reserved.
Na, Na; Shi, Ruixia; Long, Zi; Lu, Xin; Jiang, Fubin; Ouyang, Jin
2014-10-01
In this study, the real-time analysis of self-assembled nucleobases was employed by Venturi easy ambient sonic-spray ionization mass spectrometry (V-EASI-MS). With the analysis of three nucleobases including 6-methyluracil (6MU), uracil (U) and thymine (T) as examples, different orders of clusters centered with different metal ions were recorded in both positive and negative modes. Compared with the results obtained by traditional electrospray ionization mass spectrometry (ESI-MS) under the same condition, more clusters with high orders, such as [6MU7+Na](+), [6MU15+2NH4](2+), [6MU10+Na](+), [T7+Na](+), and [T15+2NH4](2+) were detected by V-EASI-MS, which demonstrated the soft ionization ability of V-EASI for studying the non-covalent interaction in a self-assembly process. Furthermore, with the injection of K(+) to the system by a syringe pumping, the real-time monitoring of the formation of nucleobases clusters was achieved by the direct extraction of samples from the system under the Venturi effect. Therefore, the effect of cations on the formation of clusters during self-assembly of nucleobases was demonstrated, which was in accordance with the reports. Free of high voltage, heating or radiation during the ionization, this technique is much soft and suitable for obtaining the real-time information of the self-assembly system, which also makes it quite convenient for extraction samples from the reaction system. This "easy and soft" ionization technique has provided a potential pathway for monitoring and controlling the self-assembly processes. Copyright © 2014 Elsevier B.V. All rights reserved.
Feasible Recycling of Industrial Waste Coal Gangue for Preparation of Mullite Based Ceramic Proppant
NASA Astrophysics Data System (ADS)
Li, Guomin; Ma, Haiqiang; Tian, Yuming; Wang, Kaiyue; Zhou, Yi; Wu, Yaqiao; Zou, Xinwei; Hao, Jianying; Bai, Pinbo
2017-09-01
Industrial waste coal gangue was successfully utilized to prepare the mullite-based ceramic proppants. The experiments involved the pelletizing technology of proppant through intensive mixer and following the sintering process under different temperatures. The crystalline phase, microstructure, density and breakage ratio of the proppants were investigated. The results showed that with the increasing of sintering temperature, the crystalline phases were transformed to rod-like mullite, which formed the cross-linked structure, improving the densification of proppants. Consequently, the breakage ratio under the closure pressure of 35 MPa exhibited declining trend and reached the minimum value of 6.8% at 1450 °C. Owing to the easy preparation, feasible design, low cost and moderate breakage ratio, the mullite-based ceramic proppant prepared by coal gangue and bauxite is promising candidate for fracturing proppants in future applications.
Yang, Ke; Huang, Xingyi; Fang, Lijun; He, Jinliang; Jiang, Pingkai
2014-12-21
Flexible nanodielectric materials with high dielectric constant and low dielectric loss have huge potential applications in the modern electronic and electric industry. Graphene sheets (GS) and reduced-graphene oxide (RGO) are promising fillers for preparing flexible polymer-based nanodielectric materials because of their unique two-dimensional structure and excellent electrical and mechanical properties. However, the easy aggregation of GS/RGO significantly limits the potential of graphene in enhancing the dielectric constant of polymer composites. In addition, the poor filler/matrix nanoscale interfacial adhesion also causes difficulties in suppressing the dielectric loss of the composites. In this work, using a facile and environmentally friendly approach, polydopamine coated RGO (PDA-RGO) and fluoro-polymer functionalized RGO (PF-PDA-RGO) were prepared. Compared with the RGO prepared by the conventional methods [i.e. hydrazine reduced-graphene oxide (H-RGO)] and PDA-RGO, the resulting PF-PDA-RGO nanosheets exhibit excellent dispersion in the ferroelectric polymer matrix [i.e. poly(vinylidene fluoride-co-hexafluoro propylene), P(VDF-HFP)] and strong interfacial adhesion with the matrix, leading to a low percolation threshold (fc = 1.06 vol%) and excellent flexibility for the corresponding nanocomposites. Among the three nanocomposites, the P(VDF-HFP)/PF-PDA-RGO nanocomposites exhibited the optimum performance (i.e. simultaneously having high dielectric constant and low dielectric loss). For instance, at 1000 Hz, the P(VDF-HFP) nanocomposite sample with 1.0 vol% PF-PDA-RGO has a dielectric constant of 107.9 and a dielectric loss of 0.070, showing good potential for dielectric applications. Our strategy provides a new pathway to prepare high performance flexible nanodielectric materials.
World's Cheapest Readout Electronics for Kinetic Inductance Detector by Using RedPitaya
NASA Astrophysics Data System (ADS)
Tomita, N.; Jeong, H.; Choi, J.; Ishitsuka, H.; Mima, S.; Nagasaki, T.; Oguri, S.; Tajima, O.
2016-07-01
The kinetic inductance detector (KID) is a cutting-edge superconducting detector. The number of KID developers is growing. Most of them have switched from their previous study to superconducting technologies. Therefore, infrastructures for the fabrication of KIDs and cooling systems for their tests have already been established. However, readout electronics have to be newly prepared. Neither a commercial system nor low-cost standard electronics are available despite various attempts to create a standard one. We suggest the use of RedPitaya as readout electronics for the initial step of KID development, which is low cost (≈ 400 USD) and easy to set up. The RedPitaya consists of an all-programmable FPGA-CPU module and a dual-channel 14 bit DAC (ADC) to generate (measure) fast analog signals with 125 MSpS. Each port can be synchronized in-phase or quadrature-phase, and functions for generating and sampling analog signal are prepared. It is straightforward to construct vector network analyzer-like logic by using a combination of these default functions. Up-conversion and down-conversion of its frequency range are also possible by using commercial equipment, i.e., mixers, couplers, and a local oscillator. We implemented direct down-conversion logic on the RedPitaya, and successfully demonstrated KID signal measurements.
One-step synthesis of fluorescent carbon dots for sensitive and selective detection of hyperin.
Liu, Lizhen; Mi, Zhi; Hu, Qin; Li, Caiqing; Li, Xiaohua; Feng, Feng
2018-08-15
In this article, we presented a new rapid, sensitive and selective method for the determination of hyperin (Hyp) based on the fluorescence quenching of fluorescent carbon dots (CDs). The CDs were prepared by simply mixing an aqueous solution of citric acid with diphosphorus pentoxide. This one-step synthetic route is fast and simple with neither high temperature nor complicated synthesis steps is involved. When Hyp was added to CDs solution, the fluorescence intensity of the CDs significantly decreased. The CDs display high selectivity for Hyp over many potentially interfering substances. Under the optimized conditions, a good linear relationship between the fluorescence intensity ratio F o /F and the concentration of Hyp is obtained in a range of 0.22-55 µM with a detection limit (S/N = 3) of 78.3 nM. The method was successfully applied for the determination of Hyp in fufangmuji granules and human serum samples with recoveries in a range of 93.3-107.0%. This paper highlights the usefulness of CDs as an effective fluorescence probe for the Hyp detection due to its easy preparation, low-cost, excellent photostability, favorable biocompatibility and low cytotoxicity. Copyright © 2018 Elsevier B.V. All rights reserved.
Li, Lei; Sheng, Qinglin; Zheng, Jianbin; Zhang, Hongfang
2008-11-01
A glucose biosensor based on polyvinylpyrrolidone (PVP) protected Prussian blue nanoparticles (PBNPs)-polyaniline/multi-walled carbon nanotubes hybrid composites was fabricated by electrochemical method. A novel route for PBNPs preparation was applied in the fabrication with the help of PVP, and from scanning electron microscope images, Prussian blue particles on the electrode were found nanoscaled. The biosensor exhibits fast current response (<6 s) and a linearity in the range from 6.7x10(-6) to 1.9x10(-3) M with a high sensitivity of 6.28 microA mM(-1) and a detection limit of 6x10(-7) M (S/N=3) for the detection of glucose. The apparent activation energy of enzyme-catalyzed reaction and the apparent Michaelis-Menten constant are 23.9 kJ mol(-1) and 1.9 mM respectively, which suggests a high affinity of the enzyme-substrate. This easy and controllable construction method of glucose biosensor combines the characteristics of the components of the hybrid composites, which favors the fast and sensitive detection of glucose with improved analytical capabilities. In addition, the biosensor was examined in human serum samples for glucose determination with a recovery between 95.0 and 104.5%.
Properties of Cement Mortar and Ultra-High Strength Concrete Incorporating Graphene Oxide Nanosheets
Ouyang, Dong
2017-01-01
In this work, the effect of graphene oxide nanosheet (GONS) additives on the properties of cement mortar and ultra-high strength concrete (UHSC) is reported. The resulting GONS-cement composites were easy to prepare and exhibited excellent mechanical properties. However, their fluidity decreased with increasing GONS content. The UHSC specimens were prepared with various amounts of GONSs (0–0.03% by weight of cement). Results indicated that using 0.01% by weight of cement GONSs caused a 7.82% in compressive strength after 28 days of curing. Moreover, adding GONSs improved the flexural strength and deformation ability, with the increase in flexural strength more than that of compressive strength. Furthermore, field-emission scanning electron microscopy (FE-SEM) was used to observe the morphology of the hardened cement paste and UHSC samples. FE-SEM observations showed that the GONSs were well dispersed in the matrix and the bonding of the GONSs and the surrounding cement matrix was strong. Furthermore, FE-SEM observation indicated that the GONSs probably affected the shape of the cement hydration products. However, the growth space for hydrates also had an important effect on the morphology of hydrates. The true hydration mechanism of cement composites with GONSs needs further study. PMID:28726750
Słomka, Marcin; Sobalska-Kwapis, Marta; Wachulec, Monika; Bartosz, Grzegorz; Strapagiel, Dominik
2017-11-03
High resolution melting (HRM) is a convenient method for gene scanning as well as genotyping of individual and multiple single nucleotide polymorphisms (SNPs). This rapid, simple, closed-tube, homogenous, and cost-efficient approach has the capacity for high specificity and sensitivity, while allowing easy transition to high-throughput scale. In this paper, we provide examples from our laboratory practice of some problematic issues which can affect the performance and data analysis of HRM results, especially with regard to reference curve-based targeted genotyping. We present those examples in order of the typical experimental workflow, and discuss the crucial significance of the respective experimental errors and limitations for the quality and analysis of results. The experimental details which have a decisive impact on correct execution of a HRM genotyping experiment include type and quality of DNA source material, reproducibility of isolation method and template DNA preparation, primer and amplicon design, automation-derived preparation and pipetting inconsistencies, as well as physical limitations in melting curve distinction for alternative variants and careful selection of samples for validation by sequencing. We provide a case-by-case analysis and discussion of actual problems we encountered and solutions that should be taken into account by researchers newly attempting HRM genotyping, especially in a high-throughput setup.
Słomka, Marcin; Sobalska-Kwapis, Marta; Wachulec, Monika; Bartosz, Grzegorz
2017-01-01
High resolution melting (HRM) is a convenient method for gene scanning as well as genotyping of individual and multiple single nucleotide polymorphisms (SNPs). This rapid, simple, closed-tube, homogenous, and cost-efficient approach has the capacity for high specificity and sensitivity, while allowing easy transition to high-throughput scale. In this paper, we provide examples from our laboratory practice of some problematic issues which can affect the performance and data analysis of HRM results, especially with regard to reference curve-based targeted genotyping. We present those examples in order of the typical experimental workflow, and discuss the crucial significance of the respective experimental errors and limitations for the quality and analysis of results. The experimental details which have a decisive impact on correct execution of a HRM genotyping experiment include type and quality of DNA source material, reproducibility of isolation method and template DNA preparation, primer and amplicon design, automation-derived preparation and pipetting inconsistencies, as well as physical limitations in melting curve distinction for alternative variants and careful selection of samples for validation by sequencing. We provide a case-by-case analysis and discussion of actual problems we encountered and solutions that should be taken into account by researchers newly attempting HRM genotyping, especially in a high-throughput setup. PMID:29099791
Wang, Yuanpeng; Sun, Ying; Gao, Yan; Xu, Bo; Wu, Qiong; Zhang, Hanqi; Song, Daqian
2014-02-01
The polyaniline-coated magnetic particles with bowl-shaped morphology (Fe3O4/C/PANI microbowls) were successfully prepared and characterized by scanning electron microscopy, transmission electron microscopy and vibrating sample magnetometry. The prepared microbowls were used as the magnetic adsorbent in dispersive solid phase extraction of five pyrethroids, including cyhalothrin, beta-cypermethrin, esfenvalerate, permethrin and bifenthrin in plain tea drinks. The effects of experiment factors, including amount of Fe3O4/C/PANI microbowls, pH value, ultrasound extraction time and desorption conditions, were investigated. The extraction recoveries obtained with 8 mg of magnetic microbowls were satisfactory, and the microbowls can be reused after easy washing. Thus, a simple, selective and effective method for the determination of the pyrethroids was established successfully. The results showed that the method had good linearity (r=0.9992-0.9998), and the limits of detections (LODs) were from 0.025 to 0.032 ng mL(-1). The intra-day and inter-day relative standard deviations (RSDs) were in the range of 2.4-6.1% and 3.5-8.8%, respectively. Recoveries obtained by analyzing the real tea drinks were in the range of 72.1-118.4%. © 2013 Published by Elsevier B.V.
Phipps, William S; Yin, Zhizhong; Bae, Candice; Sharpe, Julia Z; Bishara, Andrew M; Nelson, Emily S; Weaver, Aaron S; Brown, Daniel; McKay, Terri L; Griffin, DeVon; Chan, Eugene Y
2014-11-13
Until recently, astronaut blood samples were collected in-flight, transported to earth on the Space Shuttle, and analyzed in terrestrial laboratories. If humans are to travel beyond low Earth orbit, a transition towards space-ready, point-of-care (POC) testing is required. Such testing needs to be comprehensive, easy to perform in a reduced-gravity environment, and unaffected by the stresses of launch and spaceflight. Countless POC devices have been developed to mimic laboratory scale counterparts, but most have narrow applications and few have demonstrable use in an in-flight, reduced-gravity environment. In fact, demonstrations of biomedical diagnostics in reduced gravity are limited altogether, making component choice and certain logistical challenges difficult to approach when seeking to test new technology. To help fill the void, we are presenting a modular method for the construction and operation of a prototype blood diagnostic device and its associated parabolic flight test rig that meet the standards for flight-testing onboard a parabolic flight, reduced-gravity aircraft. The method first focuses on rig assembly for in-flight, reduced-gravity testing of a flow cytometer and a companion microfluidic mixing chip. Components are adaptable to other designs and some custom components, such as a microvolume sample loader and the micromixer may be of particular interest. The method then shifts focus to flight preparation, by offering guidelines and suggestions to prepare for a successful flight test with regard to user training, development of a standard operating procedure (SOP), and other issues. Finally, in-flight experimental procedures specific to our demonstrations are described.
Bae, Candice; Sharpe, Julia Z.; Bishara, Andrew M.; Nelson, Emily S.; Weaver, Aaron S.; Brown, Daniel; McKay, Terri L.; Griffin, DeVon; Chan, Eugene Y.
2014-01-01
Until recently, astronaut blood samples were collected in-flight, transported to earth on the Space Shuttle, and analyzed in terrestrial laboratories. If humans are to travel beyond low Earth orbit, a transition towards space-ready, point-of-care (POC) testing is required. Such testing needs to be comprehensive, easy to perform in a reduced-gravity environment, and unaffected by the stresses of launch and spaceflight. Countless POC devices have been developed to mimic laboratory scale counterparts, but most have narrow applications and few have demonstrable use in an in-flight, reduced-gravity environment. In fact, demonstrations of biomedical diagnostics in reduced gravity are limited altogether, making component choice and certain logistical challenges difficult to approach when seeking to test new technology. To help fill the void, we are presenting a modular method for the construction and operation of a prototype blood diagnostic device and its associated parabolic flight test rig that meet the standards for flight-testing onboard a parabolic flight, reduced-gravity aircraft. The method first focuses on rig assembly for in-flight, reduced-gravity testing of a flow cytometer and a companion microfluidic mixing chip. Components are adaptable to other designs and some custom components, such as a microvolume sample loader and the micromixer may be of particular interest. The method then shifts focus to flight preparation, by offering guidelines and suggestions to prepare for a successful flight test with regard to user training, development of a standard operating procedure (SOP), and other issues. Finally, in-flight experimental procedures specific to our demonstrations are described. PMID:25490614
ERIC Educational Resources Information Center
Kleinschmidt, Andy
2011-01-01
The importance of healthy soil and of conveying the importance of soils starts by conveying a few basic concepts of soil science cannot be overstated. This article provides three hands-on exercises Extension professionals can add to natural resources or Master Gardener education curricula. These natural sciences exercises are easy to prepare for…
Key Competencies, Science Education: Secondary Schools (Junior High, J-G Sci) (Senior High, S-Bio).
ERIC Educational Resources Information Center
Kelner, Bernard G.; Hofkin, Fred M.
Presented is a list of behavioral objectives which can be used to evaluate mastery of the competency of students in junior high school science and senior high school biology. These competencies were prepared by the School District of Philadelphia. The lists are comprehensive and coded for easy reference. (CS)
EASI Street to Science and Math for K-12 Students.
ERIC Educational Resources Information Center
Cunningham, Carmela; Noble, Steve
This paper discusses the poor preparation of children with disabilities in math and science fields, and the perception that students with disabilities are not capable of doing work in science and math, which is often reinforced by teachers and parents. It is argued that the low expectations and waived requirements for children with disabilities…
The Analytic Hierarchy Process (AHP) Approach for Assessment of Urban Renewal Proposals
ERIC Educational Resources Information Center
Lee, Grace K. L.; Chan, Edwin H. W.
2008-01-01
The problem of urban decay in Hong Kong is getting worse recently; therefore, the importance of urban renewal in improving the physical environment conditions and the living standards of the citizens is widely recognized in the territory. However, it is not an easy task for the Hong Kong Government to prepare welcome urban renewal proposals…
ERIC Educational Resources Information Center
Hansen, Kathryn D.; Dawson, Debra L.; Specht, Jacqueline A.
2017-01-01
Despite increasing rates of entry, students with learning disabilities (LD) continue to face barriers to completing post-secondary education. Faculty attitudes and knowledge are important factors in supporting students with LD, yet little is known about faculty preparation. No valid, reliable, easy-to-administer inventory exists to assess the…
Cationic Cyclizations and Rearrangements Promoted by a Heterogeneous Gold Catalyst
2015-01-01
A heterogeneous gold catalyst with remarkable activity for promoting the electrophilic reactions of aryl vinyl ketones and aryl dienyl ketones is described. The catalyst is easy to prepare, is robust, and can be recycled. Low loadings are effective for different types of cationic reactions, including Nazarov cyclizations, lactonizations, and [1,2] shifts. PMID:24432741
Roadblocks on the Information Highway
ERIC Educational Resources Information Center
Celano, Donna; Neuman, Susan B.
2010-01-01
As blogs light up with lively conversations about iPads, netbooks, and smart phones, it's easy to forget one major roadblock to preparing all children for the future: the digital divide. Although middle-class students often take high-speed Internet access for granted, a full 65 percent of Americans who make less than $25,000 a year lack broadband…
ERIC Educational Resources Information Center
Markey, Mia K.
2008-01-01
As the author prepares to head back to Illinois Mathematics and Science Academy (IMSA) for homecoming, she finds the analogy of Hogwarts for IMSA to be apropos. Going to IMSA opened doors for her that she hadn't even known were closed. Yet it's not easy to pin down what made her IMSA experience magical. Certainly there are some elements that are…
Summary of Internet Terms and Resources. NRC Fact Sheet
ERIC Educational Resources Information Center
Zubal, Rachael; Hall, Mair
2010-01-01
What is the Internet? The Internet is a worldwide network of computers communicating with each other. This paper offers some basic, easy-to-understand meanings of words about the Internet that individuals may have questions about.[The preparation of this fact sheet was supported in part by the National Resource Center on Supported Living and…
Casting Control of Floating-films into Ribbon-shape Structure by modified Dynamic FTM
NASA Astrophysics Data System (ADS)
Tripathi, A.; Pandey, M.; Nagamatsu, S.; Pandey, S. S.; Hayase, S.; Takashima, W.
2017-11-01
We have developed a new method to obtain Ribbon-shaped floating films via dynamic casting of floating-film and transfer method (dynamic-FTM). Dynamic-FTM is a unique method to prepare oriented thin-film of conjugated polymers (CPs) which is quick and easy. This method has several advantages as compared to the other conventional casting procedure to prepare oriented CP films. In the conventional dynamic FTM appearance of large scale circular orientation poses difficulty not only for practical applications but also hinders the detailed analysis of the orientation mechanism. In this present work, pros and cons of this newly proposed ribbon-shaped floating-film have been discussed in detail from those of the conventional floating-film prepared by dynamic-FTM.
The role of Apamarga Kshara in the treatment of Arsha
Dudhamal, T. S.; Gupta, S. K.; Bhuyan, Chaturbhuj; Singh, Kulwant
2010-01-01
As per the available treatment modalities of Arsha, the Kshara karma modality is the best one, taking into the consideration its convenience, easy adoptability, cost-effectiveness and curative results. Under this parasurgical procedure, various forms of external kshara application are used in treating the Arsha. These are Ksharasutra Ligation (KSL), ksharpatan, etc. KSL is a surgical procedure, while ksharapatan vidhi is local application and seems to be effective with an easy procedure. Several studies of ksharapatan had been conducted; so the time has come to specify the study of ksharapatan, e.g., according to degree of pile mass and different symptoms and signs. In this present study, apamarga (Achyranthus aspera Linn.) kshara, one among the best qualitative ksharas, was locally applied directly on the different sizes, shapes and degrees of Arsha, to find out its effectiveness with or without any untoward effect. A total of 30 patients were treated by local application of Apamarga kshara. The ksharapatan was done every day, for 7 days in 3 g dose, and the result was assessed thoroughly on the basis of observation according to the specially designed proforma. Apamarga kshara was prepared as per the standard method described in Ayurvedic texts. Patients suffering from Arsha were selected by simple random sampling method, with the complaints of bleeding per rectum, Vedana, Srava, kandu and prolapse. Lastly, it was concluded that ksharapatan had shown significant improvement in 1st and 2nd degree of pile masses without any side effect. PMID:22131716
The role of Apamarga Kshara in the treatment of Arsha.
Dudhamal, T S; Gupta, S K; Bhuyan, Chaturbhuj; Singh, Kulwant
2010-04-01
As per the available treatment modalities of Arsha, the Kshara karma modality is the best one, taking into the consideration its convenience, easy adoptability, cost-effectiveness and curative results. Under this parasurgical procedure, various forms of external kshara application are used in treating the Arsha. These are Ksharasutra Ligation (KSL), ksharpatan, etc. KSL is a surgical procedure, while ksharapatan vidhi is local application and seems to be effective with an easy procedure. Several studies of ksharapatan had been conducted; so the time has come to specify the study of ksharapatan, e.g., according to degree of pile mass and different symptoms and signs. In this present study, apamarga (Achyranthus aspera Linn.) kshara, one among the best qualitative ksharas, was locally applied directly on the different sizes, shapes and degrees of Arsha, to find out its effectiveness with or without any untoward effect. A total of 30 patients were treated by local application of Apamarga kshara. The ksharapatan was done every day, for 7 days in 3 g dose, and the result was assessed thoroughly on the basis of observation according to the specially designed proforma. Apamarga kshara was prepared as per the standard method described in Ayurvedic texts. Patients suffering from Arsha were selected by simple random sampling method, with the complaints of bleeding per rectum, Vedana, Srava, kandu and prolapse. Lastly, it was concluded that ksharapatan had shown significant improvement in 1st and 2nd degree of pile masses without any side effect.
Zhu, Yulong; Liu, Xingang; Xu, Jun; Dong, Fengshou; Liang, Xuyang; Li, Minmin; Duan, Lifang; Zheng, Yongquan
2013-07-19
A modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) method for the simultaneous determination of spirotetramat and its four metabolites in fruits (apple, peach) and vegetables (cabbage, tomato, potato, cucumber), based on the use of liquid extraction/partition and dispersive solid phase extraction (dispersive-SPE) followed by ultrahigh-performance chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS), was established. Acidified acetonitrile (containing 1% (v/v) acetic acid) as the extraction solvent and simultaneous liquid-liquid partitioning formed by adding anhydrous magnesium sulfate (MgSO4) and anhydrous sodium acetate (NaOAc). The extract was then cleaned up by dispersive-SPE using graphitized carbon black (GCB) as selective sorbent. Further optimization of sample preparation and determination achieved recoveries of between 82 and 110% for all analytes with RSD values lower than 14% in apple, peach, cabbage, tomato, potato and cucumber at three levels (10, 100 and 1000μg/kg). The method showed excellent linearity (R(2)≥0.9895) for all studied analytes. The determination of the target compounds was achieved in less than 6.0min using an electrospray ionization source in positive mode (ESI+). The method is demonstrated to be convenient and reliable for the routine monitoring of spirotetramat and its metabolites in fruits and vegetables. Copyright © 2013 Elsevier B.V. All rights reserved.
AlGhazali, N; Burnside, G; Smith, R W; Preston, A J; Jarad, F D
2011-12-01
Four different shades were used to produce 20 samples of resin-based composite and 20 samples of porcelain to evaluate the performance ability of an intra oral test spectrophotometer compared to a reference spectrophotometer. The absolute colour coordinates CIELAB values measured with both spectrophotometers were significantly different (p < 0.001). However, a high correlation was found (p < 0.001) despite the low concordance noticed. The colour difference deltaE* values calculated between different shades also were significantly different between both spectrophotometers (p < 0.05). Therefore, the Easy Shade can be used in dental practice and dental research with some limitations.
A Citizen Science Soil Moisture Sensor to Support SMAP Calibration/Validation
NASA Astrophysics Data System (ADS)
Podest, E.; Das, N. N.
2016-12-01
The Soil Moisture Active Passive (SMAP) satellite mission was launched in Jan. 2015 and is currently acquiring global measurements of soil moisture in the top 5 cm of the soil every 3 days. SMAP has partnered with the GLOBE program to engage students from around the world to collect in situ soil moisture and help validate SMAP measurements. The current GLOBE SMAP soil moisture protocol consists in collecting a soil sample, weighing, drying and weighing it again in order to determine the amount of water in the soil. Preparation and soil sample collection can take up to 20 minutes and drying can take up to 3 days. We have hence developed a soil moisture measurement device based on Arduino-like microcontrollers along with off-the-shelf and homemade sensors that are accurate, robust, inexpensive and quick and easy to use so that they can be implemented by the GLOBE community and citizen scientists alike. This talk will discuss building, calibration and validation of the soil moisture measuring device and assessing the quality of the measurements collected. This work was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under contract with the National Aeronautics and Space Administration.
Fluorescent carbon nanodots for sensitive and selective detection of tannic acid in wines.
Ahmed, Gaber Hashem Gaber; Laíño, Rosana Badía; Calzón, Josefa Angela García; García, Marta Elena Díaz
2015-01-01
Herein we describe an easy one step synthesis of carbon nanodots (C-dots) by thermal carbonization of 6-bromohexylboronic acid using two different amine compounds, polyethyleneglycol bis(3-aminopropyl (PEGA) and 1,2-aminopropane (DPA), at 180 °C in atmospheric oxygen. The as-synthesized C-dots were characterized by FTIR, HRTEM, NMR and fluorescence. The C-dots prepared using PEGA showed a strong emission at 440 nm with excitation at 362 nm. These C-dots exhibited analytical potential as sensing probes for tannic acid (TA) determination. pH effect, interferences, and analytical performance of the method were investigated. The method was found effective in the linear concentration range from 0.1 to 10 mg L(-1) TA achieving a limit of detection equal 0.018 mg L(-1) TA. The applicability of the method was demonstrated by direct measurements of TA in red and white wine samples. Validation of the method was achieved by spiking the wine samples with different standard TA concentrations obtaining recoveries in the range (90-112.5%). A probable mechanism by which TA quenched the C-dots fluorescence was proposed. Copyright © 2014 Elsevier B.V. All rights reserved.
Matrix-Matching as an Improvement Strategy for the Detection of Pesticide Residues.
Giacinti, Géraldine; Raynaud, Christine; Capblancq, Sophie; Simon, Valérie
2016-05-01
More than 90% of the pesticides residues in apples are located in the peel. We developed a gas chromatography/ion trap tandem mass spectrometry method for investigating all detectable residues in the peel of 3 apple varieties. Sample preparation is based on the use of the Quick Easy Cheap Effective Rugged and Safe method on the whole fruit, the flesh, and the peel. Pesticide residues were quantified with solvent-matched and matrix-matched standards, by spiking apple sample extracts. Matrix effects dependent on the type of extract (fruit, flesh, or peel) and the apple variety were detected. The best data processing methods involved normalizing matrix effect rates by matrix-matched internal/external calibration. Boscalid, captan, chlorpyrifos, fludioxonil, and pyraclostrobin were the most frequently detected pesticides. However, their concentrations in the whole fruit were below European maximum residue levels. Despite negative matrix effects, the residues in peel were detected at concentrations up to 10 times higher than those in whole fruits. Consequently, other pesticide residues present at concentrations below the limit of quantification in the whole fruit were detected in the peel. © 2016 Institute of Food Technologists®
Zhang, Xiaona; Niu, Jiahua; Zhang, Xiaoting; Xiao, Rui; Lu, Minghua; Cai, Zongwei
2017-03-01
In this research, a modified Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) method based on graphene oxide@SiO 2 (SiO 2 @GO) nanocomposite as adsorbent of dispersive solid-phase extraction (dSPE) combined with high performance liquid chromatography (HPLC) for the analysis of four plant hormones in different plants was established. The as-prepared SiO 2 @GO was characterized by scanning electron microscopy, transmission electron microscopy and infrared spectroscopy. The experimental conditions for dSPE, including the ratio of material to liquid, pH of sample, adsorption and desorption time, desorption temperature as well as desorption solution, were investigated. The detection limits for the analysis of indole-3-acetic acid, indole-3-butyric acid, 1-naphthylacetic acid and abscisic acid were achieved below 0.05μgmL -1 . The established method was applied to the analysis of the plant hormones in fruits, vegetables and other food samples. The obtained results indicated that the method was sensitive, accurate, convenient and quick, which provided an alternative analytical approach for plant hormones in complex matrices. Copyright © 2017 Elsevier B.V. All rights reserved.
Close-To-Practice Assessment Of Meat Freshness With Metal Oxide Sensor Microarray Electronic Nose
DOE Office of Scientific and Technical Information (OSTI.GOV)
Musatov, V. Yu.; Sysoev, V. V.; Sommer, M.
In this report we estimate the ability of KAMINA e-nose, based on a metal oxide sensor (MOS) microarray and Linear Discriminant Analysis (LDA) pattern recognition, to evaluate meat freshness. The received results show that, 1) one or two exposures of standard meat samples to the e-nose are enough for the instrument to recognize the fresh meat prepared by the same supplier with 100% probability; 2) the meat samples of two kinds, stored at 4 deg. C and 25 deg. C, are mutually recognized at early stages of decay with the help of the LDA model built independently under the e-nosemore » training to each kind of meat; 3) the 3-4 training cycles of exposure to meat from different suppliers are necessary for the e-nose to build a reliable LDA model accounting for the supplier factor. This study approves that the MOS e-nose is ready to be currently utilised in food industry for evaluation of product freshness. The e-nose performance is characterized by low training cost, a confident recognition power of various product decay conditions and easy adjustment to changing conditions.« less
Automatic multiple applicator electrophoresis
NASA Technical Reports Server (NTRS)
Grunbaum, B. W.
1977-01-01
Easy-to-use, economical device permits electrophoresis on all known supporting media. System includes automatic multiple-sample applicator, sample holder, and electrophoresis apparatus. System has potential applicability to fields of taxonomy, immunology, and genetics. Apparatus is also used for electrofocusing.
NASA Astrophysics Data System (ADS)
Zamil, Mohammad Shafayet
The physical and mechanical properties of cell walls, their shape, how they are arranged and interact with each other determine the architecture of plant organs and how they mechanically respond to different environmental and loading conditions. Due to the distinctive hierarchy from subcellular to tissue scale, plant materials can exhibit remarkably different mechanical properties. To date, how the subcellular scale arrangement and the mechanical properties of plant cell wall structural constituents give rise to macro or tissue scale mechanical responses is not yet well understood. Although the tissue scale plant cell wall samples are easy to prepare and put to different types of mechanical tests, the hierarchical features that emerge when moving towards a higher scale make it complicated to link the macro scale results to micro or subcellular scale structural components. On the other hand, the microscale size of cell brings formidable challenges to prepare and grip samples and carry mechanical tests under tensile loading at subcellular scale. This study attempted to develop a set of test protocols based on microelectromechanical system (MEMS) tensile testing devices for characterizing plant cell wall materials at different length scales. For the ease of sample preparation and well established database of the composition and conformation of its structural constituents, onion epidermal cell wall profile was chosen as the study material. Based on the results and findings of multiscale mechanical characterization, a framework of architecture-based finite element method (FEM) computational model was developed. The computational model laid the foundation of bridging the subcellular or microscale to the tissue or macroscale mechanical properties. This study suggests that there are important insights of cell wall mechanics and structural features that can only be investigated by carrying tensile characterization of samples not confounded by extracellular parameters. To the best of our knowledge, the plant cell wall at subcellular scale was never characterized under tensile loading. By coupling the structure based multiscale modeling and mechanical characterizations at different length scales, an attempt was made to provide novel insights towards understanding the mechanics and architecture of cell wall. This study also suggests that a multiscale investigation is essential for garnering fundamental insights into the hierarchical deformation of biological systems.
NASA Technical Reports Server (NTRS)
Coleman, E. A.
1980-01-01
Scientific information from previous space flights, space medicine, exercise physiology, and sports medicine was used to prepare a physical fitness manual suitable for use by members of the NASA astronaut population. A variety of scientifically valid exercise programs and activities suitable for the development of physical fitness are provided. Programs, activities, and supportive scientific data are presented in a concise, easy to read format so as to permit the user to select his or her mode of training with confidence and devote time previously spent experimenting with training routines to preparation for space flight. The programs and activities included were tested and shown to be effective and enjoyable.
Preparation and magnetic properties of cylindrical NiFe films and antidot arrays.
Sanz, R; Navas, D; Vazquez, M; Hernández-Vélez, M; Ross, C A
2010-10-01
Continuous NiFe (Permalloy) cylindrical films and arrays of cylindrical NiFe antidots 7 nm thick have been prepared by sputtering onto cylindrical aluminum wires and onto wires anodized to form a porous anodic alumina layer. The antidots are arranged in a close-packed pattern determined by the hexagonal pore arrangement in the porous alumina, with period 103 nm and diameter 42 nm. Hysteresis loops were measured at different angles with respect to the cylinder axis and indicate an easy plane normal to the radius of the wire. The antidots enhance the coercivity compared to the continuous cylindrical film.
Harry T. Valentine; David L. R. Affleck; Timothy G. Gregoire
2009-01-01
Systematic sampling is easy, efficient, and widely used, though it is not generally recognized that a systematic sample may be drawn from the population of interest with or without restrictions on randomization. The restrictions or the lack of them determine which estimators are unbiased, when using the sampling design as the basis for inference. We describe the...
Stroope, Samuel; Tom, Joshua C
2017-09-01
Religious participation is linked to numerous positive safety outcomes for adolescents. Scant attention, however, has been paid to associations between religious participation and safety risks among adolescents. Using data from Add Health (N = 18,449), a nationally representative school-based sample of US adolescents, this study examines the relationship between adolescents' religious affiliation and easy access to firearms at home. Regression analyses adjust for complex sampling design and compare easy firearm access at home among conservative Protestant adolescents to adolescent firearm access in other religious traditions. Conservative Protestant adolescents have a substantially greater likelihood of easy access to a gun at home compared to adolescents of all other major religious traditions in the United States. Recognizing differences in adolescent firearm access between subcultural groups can help public health interventions more effectively identify and address the needs of vulnerable populations. The paper's conclusion considers suggestions for effective policy and programmatic initiatives. Copyright © 2017 Elsevier Inc. All rights reserved.
Xu, Guangkuan; Hao, Changchun; Tian, Suyang; Gao, Feng; Sun, Wenyuan; Sun, Runguang
2017-01-15
This study investigated a new and easy-to-industrialized extracting method for curcumin from Curcuma longa rhizomes using ultrasonic extraction technology combined with ammonium sulfate/ethanol aqueous two-phase system (ATPS), and the preparation of curcumin using the semi-preparative HPLC. The single-factor experiments and response surface methodology (RSM) were utilized to determine the optimal material-solvent ratio, ultrasonic intensity (UI) and ultrasonic time. The optimum extraction conditions were finally determined to be material-solvent rate of 3.29:100, ultrasonic intensity of 33.63W/cm 2 and ultrasonic time of 17min. At these optimum conditions, the extraction yield could reach 46.91mg/g. And the extraction yields of curcumin remained stable in the case of amplification, which indicated that scale-up extraction was feasible and efficient. Afterwards, the semi-preparative HPLC experiment was carried out, in which optimal preparation conditions were elected according to the single factor experiment. The prepared curcumin was obtained and the purity could up to 85.58% by the semi-preparative HPLC. Copyright © 2016 Elsevier B.V. All rights reserved.
Pacifici, Roberta; Marchei, Emilia; Salvatore, Francesco; Guandalini, Luca; Busardò, Francesco Paolo; Pichini, Simona
2017-08-28
Cannabis has been used since ancient times to relieve neuropathic pain, to lower intraocular pressure, to increase appetite and finally to decrease nausea and vomiting. The combination of the psychoactive cannabis alkaloid Δ9-tetrahydrocannabinol (THC) with the non-psychotropic alkaloids cannabidiol (CBD) and cannabinol (CBN) demonstrated a higher activity than THC alone. The Italian National Institute of Health sought to establish conditions and indications on how to correctly use nationally produced cannabis to guarantee therapeutic continuity in individuals treated with medical cannabis. The evaluation of cannabinoids concentration and stability in standardized preparations of cannabis tea and cannabis oil was conducted using an easy and fast ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) assay. Extraction efficiency of oil was significantly higher than that of water with respect to the different cannabinoids. This was especially observed in the case of the pharmacologically active THC, CBD and their acidic precursors. Fifteen minutes boiling was sufficient to achieve the highest concentrations of cannabinoids in the cannabis tea solutions. At ambient temperature, a significant THC and CBD decrease to 50% or less of the initial concentration was observed over 3 and 7 days, respectively. When refrigerated at 4 °C, similar decreasing profiles were observed for the two compounds. The cannabinoids profile in cannabis oil obtained after pre-heating the flowering tops at 145 °C for 30 min in a static oven resulted in a complete decarboxylation of cannabinoid acids CBDA and THCA-A. Nevertheless, it was apparent that heat not only decarboxylated acidic compounds, but also significantly increased the final concentrations of cannabinoids in oil. The stability of cannabinoids in oil samples was higher than that in tea samples since the maximum decrease (72% of initial concentration) was observed in THC coming from unheated flowering tops at ambient temperature. In the case of the other cannabinoids, at ambient and refrigerated temperatures, 80%-85% of the initial concentrations were measured up to 14 days after oil preparation. As the first and most important aim of the different cannabis preparations is to guarantee therapeutic continuity in treated individuals, a strictly standardized preparation protocol is necessary to assure the availability of a homogeneous product of defined stability.
Wang, Weina; Ma, Ruiyang; Wu, Qiuhua; Wang, Chun; Wang, Zhi
2013-05-15
In this study, a magnetic microsphere-confined graphene (Fe3O4@SiO2-G) was prepared as a novel adsorbent for the preconcentration of some phthalate esters in environmental water and soybean milk samples prior to high performance liquid chromatography analysis. The properties and morphology of the Fe3O4@SiO2-G were characterized by transmission electron microscopy and X-ray diffraction. This novel graphene-based magnetic nanocomposite showed great adsorptive ability toward the analytes. The method, which takes the advantages of both the high adsorption capacity of G and easy phase separation of the magnetic adsorbent from the sample solution, could avoid the time-consuming experimental procedures related to the traditional solid phase extraction. Various experimental parameters that could affect the extraction efficiencies, such as the amount of Fe3O4@SiO2-G, the extraction time, the pH of sample solution and the desorption conditions, were investigated. Under the optimum conditions, the limits of detection (S/N=3) of the method for the compounds were between 0.07 and 0.10 ng mL(-1) in water samples, and between 0.15 and 0.30 ng mL(-1) in soybean milk samples. The relative standard deviations (RSDs) varied from 2.7% to 6.1% (n=5). The recoveries of the method were in the range between 87.2% and 109.0% for environmental water and soybean milk samples. The method is suitable to determine the five phthalate esters (diallyl phthalate, di-n-propyl-phthalate, benzyl butyl phthalate, dicyclohexyl-phthalate and diethyl-hexyl-phthalate) in environmental water and soybean milk samples. Copyright © 2013 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Anderson, Daniel; Alonzo, Julie; Tindal, Gerald
2011-01-01
In this technical report, we document the results of a cross-validation study designed to identify optimal cut-scores for the use of the easyCBM[R] mathematics test in the state of Washington. A large sample, randomly split into two groups of roughly equal size, was used for this study. Students' performance classification on the Washington state…
A Cross-Validation of easyCBM[R] Mathematics Cut Scores in Oregon: 2009-2010. Technical Report #1104
ERIC Educational Resources Information Center
Anderson, Daniel; Alonzo, Julie; Tindal, Gerald
2011-01-01
In this technical report, we document the results of a cross-validation study designed to identify optimal cut-scores for the use of the easyCBM[R] mathematics test in Oregon. A large sample, randomly split into two groups of roughly equal size, was used for this study. Students' performance classification on the Oregon state test was used as the…
NASA Astrophysics Data System (ADS)
Major, István; Gyökös, Brigitta; Túri, Marianna; Futó, István; Filep, Ágnes; Hoffer, András; Molnár, Mihály
2016-04-01
Comprehensive atmospheric studies have demonstrated that carbonaceous aerosol is one of the main components of atmospheric particulate matter over Europe. Various methods, considering optical or thermal properties, have been developed for quantification of the accurate amount of both organic and elemental carbon constituents of atmospheric aerosol. The aim of our work was to develop an alternative fast and easy method for determination of the total carbon content of individual aerosol samples collected on prebaked quartz filters whereby the mass and surface concentration becomes simply computable. We applied the conventional "elemental analyzer (EA) coupled online with an isotope ratio mass spectrometer (IRMS)" technique which is ubiquitously used in mass spectrometry. Using this technique we are able to measure simultaneously the carbon stable isotope ratio of the samples, as well. During the developing process, we compared the EA-IRMS technique with an off-line catalytic combustion method worked out previously at Hertelendi Laboratory of Environmental Studies (HEKAL). We tested the combined online total carbon content and stable isotope ratio measurement both on standard materials and real aerosol samples. Regarding the test results the novel method assures, on the one hand, at least 95% of carbon recovery yield in a broad total carbon mass range (between 100 and 3000 ug) and, on the other hand, a good reproducibility of stable isotope measurements with an uncertainty of ± 0.2 per mill. Comparing the total carbon results obtained by the EA-IRMS and the off-line catalytic combustion method we found a very good correlation (R2=0.94) that proves the applicability of both preparation method. Advantages of the novel method are the fast and simplified sample preparation steps and the fully automated, simultaneous carbon stable isotope ratio measurement processes. Furthermore stable isotope ratio results can effectively be applied in the source apportionment investigations of atmospheric carbonaceous aerosol. This research was supported by the European Union and the State of Hungary, co-financed by the European Social Fund in the framework of TÁMOP 4.2.4.A/2-11-1-2012-0001 'National Excellence Program.
Bragadeshwaran, Ashok; Kasianantham, Nanthagopal; Balusamy, Saravanan; Muniappan, SenthilKumar; Reddy, Dandu Madhu Sudan; Subhash, Randive Vishal; Pravin, Nashte Adarsh; Subbarao, Rayapati
2018-06-25
Lemon peel oil (LPO) is considered to be a viable alternative fuel for diesel engine applications due to its wider availability, renewable nature, easy extraction process, almost equivalent calorific value as neat diesel, and low viscosity. The present work aims to investigate the effect of novel emulsified LPO in a diesel engine in order to reduce the NOx emission without compromising the engine performance. A new ionic surfactant is introduced in the present study, namely methyl-dihydroxy propyl imidazolium chloride due to its higher hydrophilic-lipophilic balance value which helps to prepare stable water in oil emulsion. Also, Span 80 has been selected as another suitable surfactant for water in oil emulsion. Four emulsified fuel samples have been prepared using LPO, water, and different concentrations of surfactants. All the fuel samples are tested for their stability through gravitational technique for 7 days. Among the emulsified samples, 92% LPO + 5% water + 2% Span 80 + 1% methyl-dihydroxy propyl imidazolium chloride by volume (LPOE2) and 93.5% LPO + 5% water + 1.5% surfactant Span 80 by volume (LPOE4) have showed better stability when compared to other emulsion fuel samples. It is also revealed that the stability of LPO emulsion is improved by the addition of two emulsions. The experimental results showed that the brake thermal efficiency of LPO emulsion is reduced to 29.87 from 34.58% of pure LPO at full load condition. Oxides of nitrogen emission and smoke emission are reduced by 21-32 and 6-15% for the LPO emulsion samples compared to pure LPO. Moreover, the diesel engine operation with emulsified form of LPO increases the HC emission about 0.1 g/kWh for LPOE4 and 0.15 g/kWh for LPOE2 fuels from 0.053 g/kW for pure LPO at maximum power output condition. The reformulation of LPO into emulsified form increases the CO emission by 25-53% compared to pure LPO. Moreover, the reformulation of LPO into emulsions has resulted in lower cylinder pressure and heat release rate compared to pure LPO and diesel fuels.
Preparation and evaluation of gelling granules to improve oral administration.
Ito, Ikumi; Ito, Akihiko; Unezaki, Sakae
2015-06-01
We investigated the preparation of oral granules that are solid when stored and that will swell and gel via water absorption, to address problems experienced by patients when taking medication. Important physical properties of gelling granules include elasticity that is normally smooth, quick water absorption and swelling properties that allow easy swallowing. We selected gelatin (GEL), succinylated gelatin (SUC-GEL) and ι-carrageenan (CAR) as matrix polymers that can undergo gelation at room temperature or at cold temperatures. Saccharide and polyethylene glycol (PEG) were added to prepare the experimental granules. The best matrix gelling granule was SUC-GEL. When xylitol (XYL), sorbitol (SOR) and maltitol (MAL) were added, elasticity was improved, and PEG improved the granule's water absorption behavior, which is an important element involved in gelation. The best granules were prepared by selecting SUC-GEL as the matrix and adding a small amount of PEG and XYL in amounts equal to that of SUC-GEL.
Hyperkalemia caused by rapid red cell transfusion and the potassium absorption filter
Imashuku, Yasuhiko; Kitagawa, Hirotoshi; Mizuno, Takayoshi; Fukushima, Yutaka
2017-01-01
We report a case of transient hyperkalemia during hysterectomy after cesarean section, due to preoperatively undiagnosed placenta accreta that caused unforeseen massive hemorrhage and required rapid red cell transfusion. Hyperkalemia-induced by rapid red cell transfusion is a well-known severe complication of transfusion; however, in patients with sudden massive hemorrhage, rapid red cell transfusion is necessary to save their life. In such cases, it is extremely important to monitor serum potassium levels. For an emergency situation, a system should be developed to ensure sufficient preparation for immediate transfusion and laboratory tests. Furthermore, sufficient stock of preparations to treat hyperkalemia, such as calcium preparations, diuretics, glucose, and insulin is required. Moreover, a transfusion filter that absorbs potassium has been developed and is now available for clinical use in Japan. The filter is easy to use and beneficial, and should be prepared when it is available. PMID:28217070
A new method for the preparation of polymeric porous layer open tubular columns for GC application
NASA Technical Reports Server (NTRS)
Shen, T. C.; Wang, M. L.
1995-01-01
A new method to prepare polymeric PLOT columns by using in situ polymerization technology is described. The method involves a straightforward in situ polymerization of the monomer. The polymer produced is directly coated on the metal tubing. This eliminates many of the steps needed in conventional polymeric PLOT column preparation. Our method is easy to operate and produces very reproducible columns, as shown previously (T. C. Shen. J. Chromatogr. Sci. 30, 239, 1992). The effects of solvents, tubing pretreatments, initiators and reaction temperatures in the preparation of PLOT columns are studied. Several columns have been developed to separate (1) highly polar compounds, such as water and ammonia or water and HCN, and (2) hydrocarbons and inert gases. A recent improvement has allowed us to produce bonded polymeric PLOT columns. These were studied, and the results are included also.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhong, Lihua; He, Xiaoman; Qu, Jun
Al(OH){sub 3} and Ca(OH){sub 2} powders are co-ground to prepare a precursor which hydrates into a layered double hydroxide (LDH) phase by agitation in aqueous solution with target hexavalent chromium (Cr(VI)) at room temperature, to achieve an obvious improvement in removal efficiency of Cr(VI) through an easy incorporation into the structure. Although the prepared precursor transforms into LDH phases also when agitated in the solutions of calcium and magnesium chlorides, it incorporates Cr(VI) preferentially to the chloride salts when they coexist. The adsorption isotherm and kinetic studies show that the phenomena occurring on the Al-Ca precursor fit a pseudo-second-order kineticsmore » with a Langmuir adsorption capacity of 59.45 mg/g. Besides, characterizations of the prepared precursor and the samples after adsorption are also performed by X-ray diffraction (XRD), Fourier transform infrared (FT-IR), Transmission electron microscope (TEM) to understand the reason of the preferential incorporation of Cr(VI) to the coexisting chloride salts during the LDH phase formation. - Graphical abstract: Activated Ca-Al hydroxides (C{sub 3}A) transformed into Ca-Al-OH compound when agitated in water. Ca-Al precursor (C{sub 3}A) was agitated in a hexavalent chromium (Cr(VI)) solution to form Al-Ca-CrO{sub 4} LDH product. Ca-Al-CrO{sub 4} LDH phase occurred preferentially to Ca-Al-MCl{sub 2} LDH phases in the solutions of calcium and magnesium chlorides, it incorporates Cr(VI) preferentially to the chloride salts when they coexist. - Highlights: • Activated Ca-Al hydroxides transformed into LDH when agitated in water with some inorganic substances. • Hexavalent Cr was incorporated in the LDH structure at high adsorption capacity. • Ca-Al-Cr LDH phase occurred preferentially to Ca-Al-MCl{sub 2} LDH phases with coexistence. • The prepared Ca-Al hydroxides had high performance as adsorbent even with high salinity of the solution.« less
"Ten Things" to Enhance Learning and Fun in the Classroom
ERIC Educational Resources Information Center
Mermelstein, Aaron David
2016-01-01
This Teaching Technique introduces a fun, versatile game that gets students thinking, talking, and working together in the English as a second language (ESL) or English as a foreign language (EFL) classroom. It is easy to prepare, and it is a fun and efficient way to enhance learning. The game can be adapted to almost any grade level or ESL/EFL…
ERIC Educational Resources Information Center
Rooney, Donna; Hopwood, Nick; Boud, David; Kelly, Michelle
2015-01-01
The preparation of future professionals for practice is a key focus of higher education institutions. Among a range of approaches is the use of simulation pedagogies. While simulation is often justified as a direct bridge between higher education and professional practice, this paper questions this easy assumption. It develops a conceptually…
OK, Let's Teach Graduate Students Differently. But How?
ERIC Educational Resources Information Center
Cassuto, Leonard
2012-01-01
What should graduate teaching look like when it aims to prepare students for a range of careers? That's a welcome question, but it is not an easy one. The author takes up the problem in two parts, this month from the individual faculty member's perspective, and next month on the curricular level (that is, from the point of view of departments and…
Artisans, Architects, and Apprentices: Valuing the Craft of Teacher Education
ERIC Educational Resources Information Center
Boyd Potter, Rachel
2016-01-01
In this article, Boyd Potter describes teacher education faculty as both artisans and architects. As artisans, it is not only their products that enrich us; it is the art of the craft itself that shapes their work. An artisan is valued for the creative endeavor, and not solely the masterpiece. Preparing a quality teacher is not easy work, while…
Ultrahydrophobic Fluorinated Polyhedral Oligomeric Silsesquioxanes (F-POSS) (Preprint)
2007-01-25
From - To) 25-01-2007 Journal Article 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Ultrahydrophobic Fluorinated Polyhedral Oligomeric Silsesquioxanes...Ultrahydrophobic Fluorinated Polyhedral Oligomeric Silsesquioxanes (F-POSS) Joseph M. Mabry,* Ashwani Vij,* Scott T. Iacono, and Brent D. Viers Recently...there exists a demand to construct ultrahydrophobic materials inspired by nature that are easy to prepare on a large scale. Polyhedral oligomeric
High Cycle Life Cathode for High Voltage (5V) Lithium Ion Batteries
2010-12-16
lithium cobalt phosphate (LiCoPO4) that provides higher energy density (15% > LiFePO4 demonstrated, up to 40% greater with further R&D). •The invention...standard LiFePO4 • Higher voltage at cell level may reduce number of cells required for application • Easy and inexpensive method to prepare • Offers safety
Hua, Zihao; Vassar, Victor C.; Choi, Hojae; Ojima, Iwao
2004-01-01
Monodentate phosphoramidite ligands have been developed based on enantiopure 6,6′-dimethylbiphenols with axial chirality. These chiral ligands are easy to prepare and flexible for modifications. The fine-tuning capability of these ligands plays a significant role in achieving high enantioselectivity in the asymmetric hydroformylation of allyl cyanide and the conjugate addition of diethylzinc to cycloalkenones. PMID:15020764
Evaluation of EPE Videos in Different Phases of a Learning Process
ERIC Educational Resources Information Center
Kolas, Line; Munkvold, Robin; Nordseth, Hugo
2012-01-01
The goal of the paper is to present possible use of EPE videos in different phases of a learning and teaching process. The paper is based on an evaluation of EPE (easy production educational) videos. The evaluation framework used in this study, divides the teaching and learning process into four main phases: 1) The preparation phase, 2) The…
Pacific Pediatric Advanced Care Initiative
2009-10-01
Prepare IV ports: Identify IV ports (UVC, Femoral venous line, other central venous lines, or PIV) for easy access to push meds or administer volume...Supply Department CVL central venous line CXR chest xray DC discontinue DI Diagnostic Imaging DIC disseminated intravascular coagulation diff...programs at KMCWC. These include the blood bank, blood utilization committee, clinical laboratories, operating room, central supply, pharmacy
ERIC Educational Resources Information Center
Gonzalez, Gabriel; Seco, Miquel
2004-01-01
The potassium salt is an easy product to synthesize in an introductory course on inorganic chemistry and the students are required to prepare this product in order to improve their laboratory skills and as an introduction to the synthesis of coordination compounds. The complex potassium tris (oxalato) ferrate (III) is used to illustrate the…
A Bag Full of Newspaper Clippings and Other Tricks of the ESL Trade. TECHNIQUES.
ERIC Educational Resources Information Center
Minicz, Elizabeth Watson
1985-01-01
English as a second language (ESL) teachers find the newspaper a terrific source for easy-to-prepare reusable materials. Travel ads with coupons from the travel section can be cut out for beginning level students to complete and mail in envelopes they address. Students can find places on maps. In addition, intermediate and advanced students can…
ERIC Educational Resources Information Center
Bankert, Dabney A.; Van Vuuren, Melissa S.
2008-01-01
This is not another tired lament for a Golden Age when all students were brilliantly prepared for college, but rather an elaboration of a central pedagogical reality the authors had each separately faced--it is not easy to teach the complex set of skills subsumed under the heading "research," that organic, contingent, messy, recursive…
An Easy Method for Plant Polysome Profiling.
Lecampion, Cécile; Floris, Maïna; Fantino, Jean Raphaël; Robaglia, Christophe; Laloi, Christophe
2016-08-28
Translation of mRNA to protein is a fundamental and highly regulated biological process. Polysome profiling is considered as a gold standard for the analysis of translational regulation. The method described here is an easy and economical way for fractionating polysomes from various plant tissues. A sucrose gradient is made without the need for a gradient maker by sequentially freezing each layer. Cytosolic extracts are then prepared in a buffer containing cycloheximide and chloramphenicol to immobilize the cytosolic and chloroplastic ribosomes to mRNA and are loaded onto the sucrose gradient. After centrifugation, six fractions are directly collected from the bottom to the top of the gradient, without piercing the ultracentrifugation tube. During collection, the absorbance at 260 nm is read continuously to generate a polysome profile that gives a snapshot of global translational activity. Fractions are then pooled to prepare three different mRNA populations: the polysomes, mRNAs bound to several ribosomes; the monosomes, mRNAs bound to one ribosome; and mRNAs that are not bound to ribosomes. mRNAs are then extracted. This protocol has been validated for different plants and tissues including Arabidopsis thaliana seedlings and adult plants, Nicotiana benthamiana, Solanum lycopersicum, and Oryza sativa leaves.
A simple way to obtain backscattered electron images in a scanning transmission electron microscope.
Tsuruta, Hiroki; Tanaka, Shigeyasu; Tanji, Takayoshi; Morita, Chiaki
2014-08-01
We have fabricated a simple detector for backscattered electrons (BSEs) and incorporated the detector into a scanning transmission electron microscope (STEM) sample holder. Our detector was made from a 4-mm(2) Si chip. The fabrication procedure was easy, and similar to a standard transmission electron microscopy (TEM) sample thinning process based on ion milling. A TEM grid containing particle objects was fixed to the detector with a silver paste. Observations were carried out using samples of Au and latex particles at 75 and 200 kV. Such a detector provides an easy way to obtain BSE images in an STEM. © The Author 2014. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Wu, Enqi; Peng, Yuan; Zhang, Xihao; Bai, Jialei; Song, Yanqiu; He, Houluo; Fan, Longxing; Qu, Xiaochen; Gao, Zhixian; Liu, Ying; Ning, Baoan
2017-02-22
A new opal photonic crystal (PC) sensing material, allowing label-free detection of transferrin (TRF), is proposed in the current study. This photonic crystal was prepared via a vertical convective self-assembly method with monodisperse microspheres polymerized by methyl methacrylate (MMA) and 3-acrylamidophenylboronic acid (AAPBA). FTIR, TG, and DLS were used to characterize the components and particle size of the monodisperse microspheres. SEM was used to observe the morphology of the PC. The diffraction peak intensity decreases as the TRF concentration increase. This was due to the combination of TRF to the boronic acid group of the photonic crystal. After condition optimization, a standard curve was obtained and the linear range of TRF concentration was from 2 × 10 -3 ng/mL to 200 ng/mL. Measurement of TRF concentration in simulated urine sample was also investigated using the sensing material. The results indicated that the PC provided a cheap, label-free, and easy-to-use alternative for TRF determination in clinical diagnostics.
Colorimetric Detection of Mercury(II) Ion in Aqueous Solution Using Silver Nanoparticles.
Firdaus, M Lutfi; Fitriani, Ikka; Wyantuti, Santhy; Hartati, Yeni W; Khaydarov, Renat; McAlister, Jason A; Obata, Hajime; Gamo, Toshitaka
2017-01-01
Novel green-chemistry synthesis of silver nanoparticles (AgNPs) is introduced as a low-cost, rapid and easy-to-use analytical method for mercury ion detection. Aqueous fruit extract of water apple (Syzygium aqueum) was used for the first time as bioreductant to synthesize stable AgNPs. The prepared AgNPs have a yellowish-brown color with a surface plasmon resonance peak at 420 nm. The addition of Hg(II) ions then changes the AgNPs color to colorless. The color change was in proportion to the concentration of Hg(II) ions. The presence of other metal ions in the system was also evaluated. The proposed method shows good selectivity and sensitivity towards Hg(II) ions. Using UV-visible spectrophotometry, the detection limit of the developed method was 8.5 × 10 -7 M. The proposed method has been successfully applied for determination of Hg(II) ions in tap and lake water samples with precision better than 5%.
NASA Astrophysics Data System (ADS)
Safaei-Ghomi, Javad; Javidan, Abdollah; Ziarati, Abolfazl; Shahbazi-Alavi, Hossein
2015-08-01
In the present paper, we report the successful synthesis of nanocrystalline MIIZr4(PO4)6 ceramics (M: Mn, Ni, Fe, Co). These nano-structures were characterized by X-ray diffraction, scanning electron microscopy, and vibrating sample magnetometer (VSM). Size of nano-structures was in the range of 20-150 nm. Nano-MIIZr4(PO4)6 as an efficient and green catalyst has been used for the preparation of 2-amino-4H-pyran-3,5-dicarboxylate derivatives by the three-component condensation reaction of ethyl cyanoacetate, ethyl acetoacetate, and various aromatic aldehydes under microwave irradiation. Extraordinarily, the best results were obtained using MnZr4(PO4)6 nanocrystallines as an efficient catalyst. This method provides several advantages including easy work-up, excellent yields, short reaction times, using of microwave as green method, recoverability of the catalyst, and little catalyst loading.
Au-TiO2/Chit modified sensor for electrochemical detection of trace organophosphates insecticides.
Qu, Yunhe; Min, Hong; Wei, Yinyin; Xiao, Fei; Shi, Guoyue; Li, Xiaohua; Jin, Litong
2008-08-15
In this paper, Au-TiO2/Chit modified electrode was prepared with Au-TiO2 nanocomposite (Au-TiO2) and Chitosan (Chit) as a conjunct. The Au-TiO2 nanocomposite and the films were characterized by electrochemical and spectroscopy methods. A set of experimental conditions was also optimized for the film's fabrication. The electrochemical and electrocatalytic behaviors of Au-TiO2/Chit modified electrode to trace organophosphates (OPs) insecticides such as parathion were discussed in this work. By differential pulse voltammetry (DPV) measurement, the current responses of Au-TiO2/Chit modified electrode were linear with parathion concentration ranging from 1.0 ng/ml to 7.0 x 10(3)ng/ml with the detection limit of 0.5 ng/ml. In order to evaluate the performance of the detection system, we also examined the real samples successfully in this work. It exhibited a sensitive, rapid and easy-to-use method for the fast determination of trace OPs insecticides.
Poitevin, Frédéric; Orland, Henri; Doniach, Sebastian; Koehl, Patrice; Delarue, Marc
2011-07-01
Small Angle X-ray Scattering (SAXS) techniques are becoming more and more useful for structural biologists and biochemists, thanks to better access to dedicated synchrotron beamlines, better detectors and the relative easiness of sample preparation. The ability to compute the theoretical SAXS profile of a given structural model, and to compare this profile with the measured scattering intensity, yields crucial structural informations about the macromolecule under study and/or its complexes in solution. An important contribution to the profile, besides the macromolecule itself and its solvent-excluded volume, is the excess density due to the hydration layer. AquaSAXS takes advantage of recently developed methods, such as AquaSol, that give the equilibrium solvent density map around macromolecules, to compute an accurate SAXS/WAXS profile of a given structure and to compare it to the experimental one. Here, we describe the interface architecture and capabilities of the AquaSAXS web server (http://lorentz.dynstr.pasteur.fr/aquasaxs.php).
Consumer satisfaction with pork meat and derived products in five European countries.
Resano, Helena; Perez-Cueto, Federico J A; de Barcellos, Marcia D; Veflen-Olsen, Nina; Grunert, Klaus G; Verbeke, Wim
2011-02-01
This paper investigates consumers' satisfaction level with pork meat and derived products in five European countries. Data were collected through a cross-sectional web-based survey in Belgium, Denmark, Germany, Greece, and Poland during January 2008 with a total sample of 2437 consumers. Data included socio-demographics and questions regarding satisfaction with 27 common pork-based products; classified into fresh pork, processed pork and pork meat products. Satisfaction was evaluated in terms of overall satisfaction, as well as satisfaction with health-giving qualities, price, convenience and taste. Logistic regression analyses showed taste as the main determinant of satisfaction, followed by convenience. Healthfulness is not a significant driver of overall satisfaction. Price influences satisfaction with fresh pork more than with processed products. Tasty pork, easy to prepare and consume, with adequate promotion of its healthfulness, and with a good price/quality relationship appears to be the key factor to satisfy pork consumers. Copyright © 2010 Elsevier Ltd. All rights reserved.
Water-oil separation performance of technical textiles used for marine pollution disasters.
Seddighi, Mahdi; Hejazi, Sayyed Mahdi
2015-07-15
Oil is principally one of the most important energy sources in the world. However, as long as oil is explored and transported for being used, there will be the risk of the spillage into the marine environment. The use of technical textiles, i.e. fibrous beds, is a conventional separation technique for oil/water emulsion since it is efficient and easy to design. In this paper, the recovery of oil by technical textiles was mathematically modeled based on the structural parameters of textile and the capillary mechanism. Eleven types of commercial technical textiles with different properties were prepared for the experimental program. The experimental design included fiber type (polypropylene and polyester), fabric type (woven and/or nonwoven), fabric thickness and fabric areal density. Consequently, the absorption capacities of different technical textile samples were derived by the use of theoretical and experimental methods. The results show that there is a well fitness between theoretical outputs and experimental data. Copyright © 2015 Elsevier Ltd. All rights reserved.
A chloride-anion insensitive colorimetric chemosensor for trinitrobenzene and picric acid.
Kim, Dae-Sik; Lynch, Vincent M; Nielsen, Kent A; Johnsen, Carsten; Jeppesen, Jan O; Sessler, Jonathan L
2009-09-01
A new receptor, the bisTTF-calix[2]thiophene[2]pyrrole derivative 3, has been prepared from the Lewis acid-catalyzed condensation of 2,5-bis(1-hydroxymethylethyl)thiopheno-TTF and pyrrole. This new system is found to form complexes with the electron-deficient guests, trinitrobenzene (TNB) and picric acid (PA), which serve as models for nitroaromatic explosives. The binding phenomenon, which has been studied in organic solution using proton nuclear magnetic resonance and absorption spectroscopies, results in an easy-to-visualize color change in chloroform that is independent of the presence of chloride anion, a known interferant for an earlier tetrakisTTF-calix[4]pyrrole TNB chemosensor. Support for the proposed binding mode comes from a preliminary solid state structure of the complex formed from TNB, namely TNB subset3. A color change is also observed when dichloromethane solutions of chemosensor 3 are added to solvent-free samples of TNB, PA, and 2,4,6-trinitrotoluene supported on silica gel.
Levine, Zachary A; Rapp, Michael V; Wei, Wei; Mullen, Ryan Gotchy; Wu, Chun; Zerze, Gül H; Mittal, Jeetain; Waite, J Herbert; Israelachvili, Jacob N; Shea, Joan-Emma
2016-04-19
Translating sticky biological molecules-such as mussel foot proteins (MFPs)-into synthetic, cost-effective underwater adhesives with adjustable nano- and macroscale characteristics requires an intimate understanding of the glue's molecular interactions. To help facilitate the next generation of aqueous adhesives, we performed a combination of surface forces apparatus (SFA) measurements and replica-exchange molecular dynamics (REMD) simulations on a synthetic, easy to prepare, Dopa-containing peptide (MFP-3s peptide), which adheres to organic surfaces just as effectively as its wild-type protein analog. Experiments and simulations both show significant differences in peptide adsorption on CH3-terminated (hydrophobic) and OH-terminated (hydrophilic) self-assembled monolayers (SAMs), where adsorption is strongest on hydrophobic SAMs because of orientationally specific interactions with Dopa. Additional umbrella-sampling simulations yield free-energy profiles that quantitatively agree with SFA measurements and are used to extract the adhesive properties of individual amino acids within the context of MFP-3s peptide adhesion, revealing a delicate balance between van der Waals, hydrophobic, and electrostatic forces.
Plassmann, Merle M; Schmidt, Magdalena; Brack, Werner; Krauss, Martin
2015-09-01
Exposure to environmental pollution and consumer products may result in an uptake of chemicals into human tissues. Several studies have reported the presence of diverse environmental contaminants in human blood samples. However, previously developed multi-target methods for the analysis of human blood include a fairly limited amount of compounds stemming from one or two related compound groups. Thus, the sample preparation method QuEChERS (quick easy cheap effective rugged and safe) was tested for the extraction of 64 analytes covering a broad compound domain followed by detection using liquid and gas chromatography coupled to mass spectrometry (LC- and GC-MS). Forty-seven analytes showed absolute recoveries above 70% in the first QuEChERS step, being a simple liquid-liquid extraction (LLE) using acetonitrile and salt. The second QuEChERS step, being a dispersive solid phase extraction, did not result in an overall improvement of recoveries or removal of background signals. Using solely the LLE step, eight analytes could subsequently be detected in human blood samples from the German Environmental Specimen Bank. Using a LC-multiple reaction monitoring (MRM) method with a triple quadrupole instrument, better recoveries were achieved than with an older LC-high-resolution (HR) MS full scan orbitrap instrument, which required a higher concentration factor of the extracts. However, the application of HRMS full scan methods could be used for the detection of additional compounds retrospectively.
Witt, Sebastian; Neumann, Jan; Zierdt, Holger; Gébel, Gabriella; Röscheisen, Christiane
2012-09-01
Automated systems have been increasingly utilized for DNA extraction by many forensic laboratories to handle growing numbers of forensic casework samples while minimizing the risk of human errors and assuring high reproducibility. The step towards automation however is not easy: The automated extraction method has to be very versatile to reliably prepare high yields of pure genomic DNA from a broad variety of sample types on different carrier materials. To prevent possible cross-contamination of samples or the loss of DNA, the components of the kit have to be designed in a way that allows for the automated handling of the samples with no manual intervention necessary. DNA extraction using paramagnetic particles coated with a DNA-binding surface is predestined for an automated approach. For this study, we tested different DNA extraction kits using DNA-binding paramagnetic particles with regard to DNA yield and handling by a Freedom EVO(®)150 extraction robot (Tecan) equipped with a Te-MagS magnetic separator. Among others, the extraction kits tested were the ChargeSwitch(®)Forensic DNA Purification Kit (Invitrogen), the PrepFiler™Automated Forensic DNA Extraction Kit (Applied Biosystems) and NucleoMag™96 Trace (Macherey-Nagel). After an extensive test phase, we established a novel magnetic bead extraction method based upon the NucleoMag™ extraction kit (Macherey-Nagel). The new method is readily automatable and produces high yields of DNA from different sample types (blood, saliva, sperm, contact stains) on various substrates (filter paper, swabs, cigarette butts) with no evidence of a loss of magnetic beads or sample cross-contamination. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ceylan Koydemir, Hatice; Gorocs, Zoltan; McLeod, Euan; Tseng, Derek; Ozcan, Aydogan
2015-03-01
Giardia lamblia is a waterborne parasite that causes an intestinal infection, known as giardiasis, and it is found not only in countries with inadequate sanitation and unsafe water but also streams and lakes of developed countries. Simple, sensitive, and rapid detection of this pathogen is important for monitoring of drinking water. Here we present a cost-effective and field portable mobile-phone based fluorescence microscopy platform designed for automated detection of Giardia lamblia cysts in large volume water samples (i.e., 10 ml) to be used in low-resource field settings. This fluorescence microscope is integrated with a disposable water-sampling cassette, which is based on a flow-through porous polycarbonate membrane and provides a wide surface area for fluorescence imaging and enumeration of the captured Giardia cysts on the membrane. Water sample of interest, containing fluorescently labeled Giardia cysts, is introduced into the absorbent pads that are in contact with the membrane in the cassette by capillary action, which eliminates the need for electrically driven flow for sample processing. Our fluorescence microscope weighs ~170 grams in total and has all the components of a regular microscope, capable of detecting individual fluorescently labeled cysts under light-emitting-diode (LED) based excitation. Including all the sample preparation, labeling and imaging steps, the entire measurement takes less than one hour for a sample volume of 10 ml. This mobile phone based compact and cost-effective fluorescent imaging platform together with its machine learning based cyst counting interface is easy to use and can even work in resource limited and field settings for spatio-temporal monitoring of water quality.
ERIC Educational Resources Information Center
Anderson, Daniel; Park, Jasmine, Bitnara; Lai, Cheng-Fei; Alonzo, Julie; Tindal, Gerald
2012-01-01
This technical report is one in a series of five describing the reliability (test/retest/and alternate form) and G-Theory/D-Study research on the easy CBM reading measures, grades 1-5. Data were gathered in the spring 2011 from a convenience sample of students nested within classrooms at a medium-sized school district in the Pacific Northwest. Due…
Effect of preparation methods and doping on the structural and tunable emissions of CdS
NASA Astrophysics Data System (ADS)
Mohamed, Mohamed Bakr; Abdel-Kader, M. H.; Alhazime, Ali A.; Almarashi, Jamal Q. M.
2018-03-01
Fe, Mn and Mg doped CdS samples were prepared by thermolysis method in air and under flow of nitrogen. Structural, compositional and optical properties of the prepared samples were investigated using x-ray powder diffraction (XRD), scanning electron microscope (SEM/EDS mapping), Fourier transform infrared red (FTIR), UV-vis absorption and photoluminescence (PL) spectroscopes. Rietveld refinement of x-ray data showed that all the undoped and doped CdS samples prepared in air and under flow of nitrogen have both cubic and hexagonal structures. The percentages of hexagonal and cubic phases for all prepared samples were determined. The crystallite size increased for CdS prepared under flow of N2 compared with the sample prepared in air. The energy gap of all the samples was calculated using UV data. The intensity of PL emission changed according to the method of preparation and the kind of doping elements. PL emission revealed a blue shift for CdS prepared in air compared with CdS prepared under flow of nitrogen; also all doped samples showed a red shift of PL spectra compared with undoped samples. Undoped and doped CdS with Fe and Mg samples emitted violet and blue sub-spectra. Mn doped CdS prepared in air revealed violet, blue and yellow sub-spectra, while the sample prepared under flow of N2 emitted violet, blue and green sub-spectra.
Hochberger, J; Euler, K; Naegel, A; Hahn, E G; Maiss, J
2004-09-01
In 1997 Hochberger and Neumann presented the "Erlangen Biosimulation Model" (commercialized as the "Erlangen Endo-Trainer") at various national and international meetings. The new compactEASIE is a simplified version of the original "Biosimulation Model" (Endo-Trainer) and is specially designed for easy handling. CompactEASIE is reduced in its features, focusing exclusively on flexible endoscopy training. The acceptance of training in endoscopic hemostasis is accepted by workshop participants, as evaluated by a questionnaire on both models. Eleven structured courses on endoscopic hemostasis for doctors and nurses organized by the same endoscopists from 3/1998 to 5/1999 were evaluated using one of both models. The questionnaires were filled in by 207/291 trainees (71%). The Endo-Trainer was used in 4 (n = 103) and the compactEASIE in 7 courses (n = 104). Both simulators were equipped with identical types of specially prepared pig-organ packages consisting of esophagus, stomach and duodenum, including artificial sewn-in vessels, polyps and varices. Blood perfusion was done with a roller pump connected to the sewn-in vessels and blood surrogate. All workshops were identical concerning the course structure: a 30-min theoretical introduction on ulcer bleeding was followed by 2 h of practical training in injection techniques and hemoclip application. The second part of variceal therapy consisted of a 30-min theoretical introduction prior to 2 h of practical training on sclerotherapy, band ligation and cyanoacrylate application. Finally, a questionnaire on the trainees' pre-experience and their rating of the different workshop sections was handed out to each participant. Previous endoscopic experience was comparable in both groups. The training in both simulators was highly accepted by the trainees (compactEASIE 95% excellent and good versus EASIE (Endo-Trainer) 97%) and did not show any significant difference (P = 0.493). Even in the assessment of the single techniques, no statistical difference was observed. Furthermore, the assessments of the closeness to reality and the endoscopic environment in both simulators were identical. Both simulators (Endo-Trainer, compactEASIE) are excellent educational tools for interventional endoscopy with a high level of acceptance. The easy-to-handle, "lightweight" compactEASIE is a significant, progress tool for the future.
Shirsath, Sagar E.; Liu, Xiaoxi; Yasukawa, Yukiko; Li, Sean; Morisako, Akimitsu
2016-01-01
Perpendicular magnetization and precise control over the magnetic easy axis in magnetic thin film is necessary for a variety of applications, particularly in magnetic recording media. A strong (111) orientation is successfully achieved in the CoFe2O4 (CFO) thin film at relatively low substrate temperature of 100 °C, whereas the (311)-preferred randomly oriented CFO is prepared at room temperature by the DC magnetron sputtering technique. The oxygen-deficient porous CFO film after post-annealing gives rise to compressive strain perpendicular to the film surface, which induces large perpendicular coercivity. We observe the coercivity of 11.3 kOe in the 40-nm CFO thin film, which is the highest perpendicular coercivity ever achieved on an amorphous SiO2/Si substrate. The present approach can guide the systematic tuning of the magnetic easy axis and coercivity in the desired direction with respect to crystal orientation in the nanoscale regime. Importantly, this can be achieved on virtually any type of substrate. PMID:27435010
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butson, M; Pope, D; Whitaker, M
Purpose: Total Body Irradiation (TBI) treatments are mainly used in a preparative regimen for haematopoietic stem cell (or bone marrow) transplantation. Our standard regimen is a 12 Gy / 6 fraction bi-daily technique. To evaluate the delivered dose homogeneity to the patient, EBT3 Gafchromic film is positioned at the head, neck, chest, pelvis and groin for all fractions. A system has been developed to simply and accurately prepare and readout the films for patient dose assessment. Methods: A process involving easy preparation and analysis has been produced to minimise the time requirements for TBI dosimetry. One sheet of EBT3 filmmore » is used to prepare treatment dosimeters for all fractions, including calibration films, and an automated dose analysis system for easy evaluation and calculation of estimated in-vivo doses was developed. A desktop scanner is used with a dedicated TBI film template to accurately position the films for Image J analysis and extraction. Dental wax bolus and zip-lock bag holders are used to hold the EBT3 film in place during irradiation. Results: To adequately provide dosimetry information for a 6 fraction, TBI patient, only one sheet of Gafchromic EBT3 film is required. The dosimeters are cut, using a template, into 19 mm squares which are then placed between two 30 mm x 30 mm x 4.5 mm wax blocks for bolus. All packages are prepared before the first treatment fraction. The scanning and analysis process can be completed in less than 10 minutes after a 240 min development period. Results have shown that a high level of accuracy and reproducibility can be achieved using the template system provided. Conclusion: Gafchromic EBT3 film provides an adequate in-vivo dosimetry measure for TBI patients. Using a template based system on a dedicated desktop scanner, in-vivo results can be ascertained quickly and accurately.« less
Microstructural features of carious human enamel imaged with back-scattered electrons.
Pearce, E I; Nelson, D G
1989-02-01
We have used back-scattered electrons (BE) in the scanning electron microscope to produce mineral density images of enamel. Flat surfaces of artificially-carious enamel, softened in an intra-oral experiment, and naturally-carious (white spot) enamel were polished to a high gloss with diamond lapping compound, rendering them almost featureless by secondary electron scanning electron microscopy. They were then examined at 10 to 30 kV in a Philips 505 instrument fitted with a 4-quadrant BE detector. Study of surfaces prepared approximately parallel to the natural surface showed that mineral was lost from both prism core and the interprismatic region, leaving a thin mineral-rich rim at the prism periphery. The same lesions viewed longitudinally on a surface prepared perpendicular to the natural surface showed mineral-rich bands at the prism margins in the outer enamel. Near the advancing front of the lesion, the prism junctions were widened and the prism cores sometimes hypermineralized. Natural lesions sectioned in the prism long axis showed features previously seen with other techniques, e.g., cross-striations and striae of Retzius, but in much greater detail. Mineral enrichment at the prism periphery in the lesion body and a widening of the prism junction at the advancing fronts of lesions in permanent teeth were most obvious. Calculations showed that with an accelerating voltage of 30 kV, the images reflected mineral density up to 4 microns beneath the surface. BE microscopy produces a high-resolution image of mineral loss or gain in carious enamel, with relatively easy sample preparation.
Mateescu, Cristina; Popescu, Anca Mihaela; Radu, Gabriel Lucian; Onisei, Tatiana; Raducanu, Adina Elena
2017-01-01
Purpose: This study was carried out in order to find a reliable method for the fast detection of adulterated herbal food supplements with sexual enhancement claims. As some herbal products are advertised as "all natural", their "efficiency" is often increased by addition of active pharmaceutical ingredients such as PDE-5 inhibitors, which can be a real health threat for the consumer. Methodes: Adulterants, potentially present in 50 herbal food supplements with sexual improvement claims, were detected using 2 spectroscopic methods - Raman and Fourier Transform Infrared - known for reliability, reproductibility, and an easy sample preparation. GC-MS technique was used to confirm the potential adulterants spectra. Results: About 22% (11 out of 50 samples) of herbal food supplements with sexual enhancement claims analyzed by spectroscopic and spectrometric methods proved to be "enriched" with active pharmaceutical compounds such as: sildenafil and two of its analogues, tadalafil and phenolphthalein. The occurence of phenolphthalein could be the reason for the non-relevant results obtained by FTIR method in some samples. 91% of the adulterated herbal food supplements were originating from China. Conclusion: The results of this screening highlighted the necessity for an accurate analysis of all alleged herbal aphrodisiacs on the Romanian market. This is a first such a screening analysis carried out on herbal food supplements with sexual enhancement claims. PMID:28761827
Flint, Robert B; Bahmany, Soma; van der Nagel, Bart C H; Koch, Birgit C P
2018-05-16
A simple and specific UPLC-MS/MS method was developed and validated for simultaneous quantification of fentanyl, sufentanil, cefazolin, doxapram and its active metabolite keto-doxapram. The internal standard was fentanyl-d5 for all analytes. Chromatographic separation was achieved with a reversed phase Acquity UPLC HSS T3 column with a run-time of only 5.0 minutes per injected sample. Gradient elution was performed with a mobile phase consisting of ammonium acetate, formic acid in Milli-Q ultrapure water or in methanol with a total flow rate of 0.4 mL minute -1 . A plasma volume of only 50 μL was required to achieve both adequate accuracy and precision. Calibration curves of all 5 analytes were linear. All analytes were stable for at least 48 hours in the autosampler. The method was validated according to US Food and Drug Administration guidelines. This method allows quantification of fentanyl, sufentanil, cefazolin, doxapram and keto-doxapram, which serves purposes for research, as well as therapeutic drug monitoring, if applicable. The strength of this method is the combination of a small sample volume, a short run-time, a deuterated internal standard, an easy sample preparation method and the ability to simultaneously quantify all analytes in one run. This article is protected by copyright. All rights reserved.
Miniature Raman spectrometer development
NASA Astrophysics Data System (ADS)
Bonvallet, Joseph; Auz, Bryan; Rodriguez, John; Olmstead, Ty
2018-02-01
The development of techniques to rapidly identify samples ranging from, molecule and particle imaging to detection of high explosive materials, has surged in recent years. Due to this growing want, Raman spectroscopy gives a molecular fingerprint, with no sample preparation, and can be done remotely. These systems can be small, compact, lightweight, and with a user interface that allows for easy use and sample identification. Ocean Optics Inc. has developed several systems that would meet all these end user requirements. This talk will describe the development of different Ocean Optics Inc miniature Raman spectrometers. The spectrometer on a phone (SOAP) system was designed using commercial off the shelf (COTS) components, in a rapid product development cycle. The footprint of the system measures 40x40x14 mm (LxWxH) and was coupled directly to the cell phone detector camera optics. However, it gets roughly only 40 cm-1 resolution. The Accuman system is the largest (290x220X100 mm) of the three, but uses our QEPro spectrometer and get 7-11 cm-1 resolution. Finally, the HRS-30 measuring 165x85x40 mm is a combination of the other two systems. This system uses a modified EMBED spectrometer and gets 7-12 cm-1 resolution. Each of these units uses a peak matching algorithm that then correlates the results to the pre-loaded and customizable spectral libraries.
Oh, Jin-Gyo; Seong, Jihyun; Han, Sunmi; Heo, Tae-Hwe
2018-05-17
Immunogenicity is a major concern in the use of biological drugs. In particular, antibody-mediated pure red cell aplasia (PRCA) is a rare condition that is caused by administration of recombinant erythropoietin. There are numerous assay platforms for detect EPO anti-drug antibody (ADA), and most have appropriate assay sensitivity, but in need of improvement in terms of assay turnaround time and user accessibility. Here, the new method was developed based on lab-on-a-chip technology and bridging ELISA. The FREND™ Cartridge is equipped with a microfluidic lateral flow channel, enabling easy, fast and accurate immunoassays with small sample volumes. Biotinylated EPO was immobilized on the avidin-coated solid phase of the test zone in the FREND™ cartridge. Initially, ADA in the serum sample binds to the detector conjugate (EPO-HRP-anti HRP antibody-FL bead) in the conjugation zone, and it flows into the test zone prepared with capture complex (avidin-biotinylated EPO). Unbound detector complexes are captured in the reference zone. The FREND™ system detects and quantifies the fluorescence signals in each zone and then calculates the concentration of EPO ADA in the sample. The FREND™ EPO ADA kit may be useful in local clinics as a rapid method for monitoring patients administered recombinant erythropoietin. Copyright © 2018 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.
Mateescu, Cristina; Popescu, Anca Mihaela; Radu, Gabriel Lucian; Onisei, Tatiana; Raducanu, Adina Elena
2017-06-01
Purpose: This study was carried out in order to find a reliable method for the fast detection of adulterated herbal food supplements with sexual enhancement claims. As some herbal products are advertised as "all natural", their "efficiency" is often increased by addition of active pharmaceutical ingredients such as PDE-5 inhibitors, which can be a real health threat for the consumer. Methodes: Adulterants, potentially present in 50 herbal food supplements with sexual improvement claims, were detected using 2 spectroscopic methods - Raman and Fourier Transform Infrared - known for reliability, reproductibility, and an easy sample preparation. GC-MS technique was used to confirm the potential adulterants spectra. Results: About 22% (11 out of 50 samples) of herbal food supplements with sexual enhancement claims analyzed by spectroscopic and spectrometric methods proved to be "enriched" with active pharmaceutical compounds such as: sildenafil and two of its analogues, tadalafil and phenolphthalein. The occurence of phenolphthalein could be the reason for the non-relevant results obtained by FTIR method in some samples. 91% of the adulterated herbal food supplements were originating from China. Conclusion: The results of this screening highlighted the necessity for an accurate analysis of all alleged herbal aphrodisiacs on the Romanian market. This is a first such a screening analysis carried out on herbal food supplements with sexual enhancement claims.
A CCIR-based prediction model for Earth-Space propagation
NASA Technical Reports Server (NTRS)
Zhang, Zengjun; Smith, Ernest K.
1991-01-01
At present there is no single 'best way' to predict propagation impairments to an Earth-Space path. However, there is an internationally accepted way, namely that given in the most recent version of CCIR Report 564 of Study Group 5. This paper treats a computer code conforming as far as possible to Report 564. It was prepared for an IBM PS/2 using a 386 chip and for Macintosh SE or Mach II. It is designed to be easy to write and read, easy to modify, fast, have strong graphic capability, contain adequate functions, have dialog capability and windows capability. Computer languages considered included the following: (1) Turbo BASIC, (2) Turbo PASCAL, (3) FORTRAN, (4) SMALL TALK, (5) C++, (6) MS SPREADSHEET, (7) MS Excel-Macro, (8) SIMSCRIPT II.5, and (9) WINGZ.
Li, Yunqi; Bastakoti, Bishnu Prasad; Imura, Masataka; Dai, Pengcheng; Yamauchi, Yusuke
2015-12-01
Large-sized (ca. 40 nm) mesoporous Er2O3 thin films are synthesized by using a triblock copolymer poly(styrene-b-2-vinyl pyridine-b-ethylene oxide) (PS-b-P2VP-b-PEO) as a pore directing agent. Each block makes different contributions and the molar ratio of PVP/Er(3+) is crucial to guide the resultant mesoporous structure. An easy and general method is proposed and used to prepare a series of mesoporous rare-earth oxide (Sm2O3, Dy2O3, Tb2O3, Ho2O3, Yb2O3, and Lu2O3) thin films with potential uses in electronics and optical devices. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
González-Mancebo, E; Alonso Díaz de Durana, M D; García Estringana, Y; Meléndez Baltanás, A; Rodriguez-Alvarez, M; de la Hoz Caballer, B; Del Prado, N; Fernández-Rivas, M
The double-blind, placebo-controlled food challenge (DBPCFC) is considered the definitive diagnostic test for food allergy. Nevertheless, validated recipes for masking the foods are scarce, have not been standardized, and differ between centers. Sensory evaluation techniques such as the triangle test are necessary to validate the recipes used for DBPCFC. We developed 3 recipes for use in DBPCFC with milk, egg white, and hazelnut and used the triangle test to validate them in a 2-phase study in which 197 volunteers participated. In each phase, participants tried 3 samples (2 active-1 placebo or 2 placebo-1 active) and had to identify the odd one. In phase 1, the 3 samples were given simultaneously, whereas in phase 2, the 3 samples of foods that failed validation in phase 1 were given sequentially. A visual analog scale (VAS) ranging from 1 to 10 was used to evaluate how much participants liked the recipes. In phase 1, the egg white recipe was validated (n=89 volunteers, 38.9% found the odd sample, P=.16). Milk and hazelnut recipes were validated in phase 2 (for both foods, n=30 participants, 36.7% found the odd sample, P=.36). Median VAS scores for the 3 recipes ranged from 6.6 to 9.7. We used sensory testing to validate milk, egg white, and hazelnut recipes for use in DBPCFC. The validated recipes are easy to prepare in a clinical setting, provide the equivalent of 1 serving dose, and were liked by most participants.
Cnops, Lieselotte; Van den Eede, Peter; Pettitt, James; Heyndrickx, Leo; De Smet, Birgit; Coppens, Sandra; Andries, Ilse; Pattery, Theresa; Van Hove, Luc; Meersseman, Geert; Van Den Herrewegen, Sari; Vergauwe, Nicolas; Thijs, Rein; Jahrling, Peter B.; Nauwelaers, David; Ariën, Kevin K.
2016-01-01
Background. The 2013–2016 Ebola epidemic in West Africa resulted in accelerated development of rapid diagnostic tests for emergency outbreak preparedness. We describe the development and evaluation of the Idylla™ prototype Ebola virus test, a fully automated sample-to-result molecular diagnostic test for rapid detection of Zaire ebolavirus (EBOV) and Sudan ebolavirus (SUDV). Methods. The Idylla™ prototype Ebola virus test can simultaneously detect EBOV and SUDV in 200 µL of whole blood. The sample is directly added to a disposable cartridge containing all reagents for sample preparation, RNA extraction, and amplification by reverse-transcription polymerase chain reaction analysis. The performance was evaluated with a variety of sample types, including synthetic constructs and whole blood samples from healthy volunteers spiked with viral RNA, inactivated virus, and infectious virus. Results. The 95% limits of detection for EBOV and SUDV were 465 plaque-forming units (PFU)/mL (1010 copies/mL) and 324 PFU/mL (8204 copies/mL), respectively. In silico and in vitro analyses demonstrated 100% correct reactivity for EBOV and SUDV and no cross-reactivity with relevant pathogens. The diagnostic sensitivity was 97.4% (for EBOV) and 91.7% (for SUDV), the specificity was 100%, and the diagnostic accuracy was 95.9%. Conclusions. The Idylla™ prototype Ebola virus test is a fast, safe, easy-to-use, and near-patient test that meets the performance criteria to detect EBOV in patients with suspected Ebola. PMID:27247341
Veg-03 Pillows Preparation for Flight
2016-03-23
Inside a laboratory in the Space Station Processing Facility at NASA’s Kennedy Space Center in Florida, Michele Koralewicz, a mechanical technician with EASI on the Engineering Services Contract, prepares to sew the end of a bag that contains one of the Veg-03 plant pillows. The Veg-03 experiment will be delivered to the International Space Station aboard the eighth SpaceX Dragon commercial resupply mission. The Veg-03 plant pillows will contain ‘Tokyo Bekana’ cabbage seeds and lettuce seeds for NASA’s third Veggie plant growth system experiment. The experiment will continue NASA’s deep space plant growth research to benefit the Earth and the agency’s journey to Mars.
Multiport well design for sampling of ground water at closely spaced vertical intervals
Delin, G.N.; Landon, M.K.
1996-01-01
Detailed vertical sampling is useful in aquifers where vertical mixing is limited and steep vertical gradients in chemical concentrations are expected. Samples can be collected at closely spaced vertical intervals from nested wells with short screened intervals. However, this approach may not be appropriate in all situations. An easy-to-construct and easy-to-install multiport sampling well to collect ground-water samples from closely spaced vertical intervals was developed and tested. The multiport sampling well was designed to sample ground water from surficial sand-and-gravel aquifers. The device consists of multiple stainless-steel tubes within a polyvinyl chloride (PVC) protective casing. The tubes protrude through the wall of the PVC casing at the desired sampling depths. A peristaltic pump is used to collect ground-water samples from the sampling ports. The difference in hydraulic head between any two sampling ports can be measured with a vacuum pump and a modified manometer. The usefulness and versatility of this multiport well design was demonstrated at an agricultural research site near Princeton, Minnesota where sampling ports were installed to a maximum depth of about 12 m below land surface. Tracer experiments were conducted using potassium bromide to document the degree to which short-circuiting occurred between sampling ports. Samples were successfully collected for analysis of major cations and anions, nutrients, selected herbicides, isotopes, dissolved gases, and chlorofluorcarbon concentrations.
Renault, Cybèle A; Traore, Arouna; Machekano, Rhoderick N; Israelski, Dennis M
2010-01-01
Background: CD4+ T lymphocyte enumeration plays a critical role in the initiation and monitoring of HIV-infected patients on antiretroviral therapy. There is an urgent need for low-cost CD4+ enumeration technologies, particularly for use in dry, dusty climates characteristic of many small cities in Sub-Saharan Africa. Design: Cross-sectional study. Methods: Blood samples from 98 HIV-infected patients followed in a community HIV clinic in Ouahigouya, Burkina Faso were obtained for routine CD4+ T lymphocyte count monitoring. The blood samples were divided into two aliquots, on which parallel CD4+ measurements were performed using microcapillary (Guava EasyCD4) and dedicated (Becton Dickinson FACSCount) CD4+ enumeration systems. Spearman rank correlation coefficient was calculated, and the sensitivity, specificity and positive predictive value (PPV) for EasyCD4 <200 cells/µL were determined compared to the reference standard FACSCount CD4 <200 cells/µL. Results: Mean CD4 counts for the EasyCD4 and FACSCount were 313.75 cells/µL and 303.47 cells/µL, respectively. The Spearman rank correlation coefficient was 0.92 (p<0.001). Median values using EasyCD4 were higher than those with the FACSCount (p=0.004). For a CD4<350 cells/uL, sensitivity of the EasyCD4 was 93.9% (95%CI 85.2-98.3%), specificity was 90.6% (95% CI 75.0-98.0%), and PPV was 95.4% (95%CI 87.1-99.0%). Conclusion: Use of the EasyCD4 system was feasible and highly accurate in the harsh conditions of this remote city in Sub-Saharan Africa, demonstrating acceptable sensitivity and specificity compared to a standard operating system. Microcapillary flow cytometry offers a cost-effective alternative for community-based, point-of-care CD4+ testing and could play a substantial role in scaling up HIV care in remote, resource-limited settings. PMID:21253463
7 CFR 27.21 - Preparation of samples of cotton.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 2 2012-01-01 2012-01-01 false Preparation of samples of cotton. 27.21 Section 27.21... REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.21 Preparation of samples of cotton. The samples from each bale shall be prepared as specified in this section...
7 CFR 27.21 - Preparation of samples of cotton.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Preparation of samples of cotton. 27.21 Section 27.21... REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.21 Preparation of samples of cotton. The samples from each bale shall be prepared as specified in this section...
7 CFR 27.21 - Preparation of samples of cotton.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 2 2011-01-01 2011-01-01 false Preparation of samples of cotton. 27.21 Section 27.21... REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.21 Preparation of samples of cotton. The samples from each bale shall be prepared as specified in this section...
[Adolescents find it easy to collect their own samples to study sexually transmitted infections].
Huneeus, Andrea; Fernández, Mario I; Schilling, Andrea; Parra, Paulina; Zakharova, Aleksandra
2017-04-01
As alternative for patients that fear genital examination, we assessed adolescent's comfort and ease with self-collected samples for nucleic acid amplification testing for sexually transmitted infections. Sexually active Chilean adolescents and youth under 25 years (174 males and 117 females) were enrolled. Females used self-collected vaginal swabs and males collected first-stream urine. A satisfaction survey evaluating self-sampling system was applied. Self-collection was considered easy in 99.3% of the interviewees (CI 95% 0.88-0.98). In women, 79.3% preferred vaginal self-collected samples than pelvic exam (CI 95% 0.73-0.85). In men, 80.3% preferred self-collected first-stream urine to urethral swabs (CI 95% 0.73-0.87). Assuming that self-collected sampling were available, 89.6% of women (CI 95% 0.85-0.94) and 93.2% of men (CI 95% 0.89-0.98) would be prone to be tested more often. Ease of self-collected sampling is not associated with age, gender, educational level or poverty. Chile currently does not have sexually transmitted infections surveillance or screening programs for youth and adolescents. Given self-collected sampling's good acceptability, it could be successfully used when these programs are implemented.
NASA Astrophysics Data System (ADS)
Vos, Heleen; Foing, Bernard; Kołodziejczyk, Agata; Vago, Jorge; Harasymczuk, Matt
2017-04-01
This study focuses on the detection and characterisation of elements, minerals, volatiles and organics using reflectance spectrometry. The goal is to create a calibration method to enable the use of spectrometers on analogue Moon/Mars missions and on a lander. For this study we use measurements that are done in the VIS and NIR spectrum, as well as fluorescence using different spectrometers. The first part of the study consists of measurements that are performed in a laboratory to create a calibration method. Different rock samples and soils are analysed and the reflectance and absorption of minerals, water, organics and biomarkers are measured. Also the influence of the grain size, light source and surroundings is being determined. An experiment on the reflectance spectra of plant growth in different soils is also done to determine the possibilities of detecting the presence of chlorophyll and other biomarkers, and to diagnose the growth and health of a plant. This analysis can result in a monitoring method for a Moon greenhouse, but also for general surface analysis. Using VIS and NIR spectrometry has a couple of advantages, one being the fact that measurements require no sample preparation, and also the small size of the spectrometer makes it an easy tool for different analyses on board space missions. However, VIS and NIR spectroscopy have detection limits which makes only certain characteristics detectable. Besides laboratory measurements, the different spectroscopy methods are tested during a field campaign in the Eifel, Germany. During this campaign we can determine the functionality of the spectrometer in the field and on a lander and the problems that can rise when a spectrometer is controlled from a distant or by a person who is not trained in using spectroscopy. These laboratory and field measurements can help in the scientific preparation for instruments on ExoMars rover, future MoonMars lander missions and for the MoonVillage.
NASA Astrophysics Data System (ADS)
Kadirova, Zukhra C.; Hojamberdiev, Mirabbos; Katsumata, Ken-Ichi; Isobe, Toshihiro; Matsushita, Nobuhiro; Nakajima, Akira; Okada, Kiyoshi
2017-04-01
Fe2O3-supported activated carbon felts (Fe-ACFTs) were prepared by impregnating the felts consisted of activated carbon fibers (ACFs) with either polyester fibers (PS-A20) or polyethylene pulp (PE-W15) in Fe(III) nitrate solution and calcination at 250 °C for 1 h. The prepared Fe-ACFTs with 31-35 wt% Fe were characterized by N2-adsorption, scanning electron microscopy, and X-ray diffraction. The Fe-ACFT(PS-A20) samples with 5-31 wt% Fe were microporous with specific surface areas (SBET) ranging from 750 to 150 m2/g, whereas the Fe-ACFT(PE-W15) samples with 2-35 wt% Fe were mesoporous with SBET ranging from 830 to 320 m2/g. The deposition of iron oxide resulted in a decrease in the SBET and methylene blue (MB) adsorption capacity while increasing the photodegradation of MB. The optimum MB degradation conditions included 0.98 mM oxalic acid, pH = 3, 0.02-0.05 mM MB, and 100 mg/L photocatalyst. The negative impact of MB desorption during the photodegradation reaction was more pronounced for mesoporous PE-W15 samples and can be neglected by adding oxalic acid in cyclic experiments. Almost complete and simultaneous mineralization of oxalate and MB was achieved by the combined heterogeneous-homogeneous photocatalytic processes. The leached Fe ions in aqueous solution [Fe3+]f were measured after 60 min for every cycle and found to be about 2 ppm in all four successive cycles. The developed photocatalytic materials have shown good performance even at low content of iron oxide (2-5 wt% Fe-ACFT). Moreover, it is easy to re-impregnate the ACF when the content of iron oxide is reduced during the cyclic process. Thus, low leaching of Fe ions and possibility of cyclic usage are the advantages of the photocatalytic materials developed in this study.
A fully sealed plastic chip for multiplex PCR and its application in bacteria identification.
Xu, Youchun; Yan, He; Zhang, Yan; Jiang, Kewei; Lu, Ying; Ren, Yonghong; Wang, Hui; Wang, Shan; Xing, Wanli
2015-07-07
Multiplex PCR is an effective tool for simultaneous multiple target detection but is limited by the intrinsic interference and competition among primer pairs when it is performed in one reaction tube. Dividing a multiplex PCR into many single PCRs is a simple strategy to overcome this issue. Here, we constructed a plastic, easy-to-use, fully sealed multiplex PCR chip based on reversible centrifugation for the simultaneous detection of 63 target DNA sequences. The structure of the chip is quite simple, which contains sine-shaped infusing channels and a number of reaction chambers connecting to one side of these channels. Primer pairs for multiplex PCR were sequentially preloaded in the different reaction chambers, and the chip was enclosed with PCR-compatible adhesive tape. For usage, the PCR master mix containing a DNA template is pipetted into the infusing channels and centrifuged into the reaction chambers, leaving the infusing channels filled with air to avoid cross-contamination of the different chambers. Then, the chip is sealed and placed on a flat thermal cycler for PCR. Finally, amplification products can be detected in situ using a fluorescence scanner or recovered by reverse centrifugation for further analyses. Therefore, our chip possesses two functions: 1) it can be used for multi-target detection based on end-point in situ fluorescence detection; and 2) it can work as a sample preparation unit for analyses that need multiplex PCR such as hybridization and target sequencing. The performance of this chip was carefully examined and further illustrated in the identification of 8 pathogenic bacterial genomic DNA samples and 13 drug-resistance genes. Due to simplicity of its structure and operation, accuracy and generality, high-throughput capacity, and versatile functions (i.e., for in situ detection and sample preparation), our multiplex PCR chip has great potential in clinical diagnostics and nucleic acid-based point-of-care testing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Xiao; Wang, Hongbo; Yang, Chunming
2013-03-15
Novel Fe3O4 at TiO2 magnetic nanoparticles were prepared and developed for a new nanoparticle-based immunosensor for electrochemical quantification of organophosphorylated butyrylcholinesterase (BChE) in plasma, a specific biomarker of exposure to organophosphorus (OP) agents. The Fe3O4 at TiO2 nanoparticles were synthesized by hydrolysis of tetrabutyltitanate on the surface of Fe3O4 magnetic nanospheres, and characterized by attenuated total reflection Fourier-transform infrared spectra, transmission electron microscope and X-ray diffraction. The functional Fe3O4 at TiO2 nanoparticles were performed as capture antibody to selectively enrich phosphorylated moiety instead of phosphoserine antibody in the traditional sandwich immunoassays. The secondary recognition was served by quantum dots (QDs)-taggedmore » anti-BChE antibody (QDs-anti-BChE). With the help of a magnet, the resulting sandwich-like complex, Fe3O4 at TiO2/OP-BChE/QDs-anti-BChE, was easily isolated from sample solutions and the released cadmium ions were detected on a disposable screen-printed electrode (SPE). The binding affinities were investigated by both surface plasmon resonance (SPR) and square wave voltammetry (SWV). This method not only avoids the drawback of unavailability of commercial OP-specific antibody but also amplifies detection signal by QDs-tags together with easy separation of samples by magnetic forces. The proposed immunosensor yields a linear response over a broad OP-BChE concentrations range from 0.02 to 10 nM, with detection limit of 0.01 nM. Moreover, the disposable nanoparticle-based immunosensor has been validated with human plasma samples. It offers a new method for rapid, sensitive, selective and inexpensive screening/evaluating exposure to OP pesticides.« less
A simple technic for repeated collection of blood samples from mice.
Stoltz, D R; Bendall, R D
1975-06-01
A device for repeated collection of small blood samples from mice was constructed from a plastic syringe. Blood was collected into a 3.33 lambda capillary tube. Bleeding was stopped by a hemostat made from a rubber stopper. This technic allows easy collection of approximately 20 serial samples within an 8-hr period.
ERIC Educational Resources Information Center
Anderson, Daniel; Lai, Cheg-Fei; Park, Bitnara Jasmine; Alonzo, Julie; Tindal, Gerald
2012-01-01
This technical report is one in a series of five describing the reliability (test/retest an alternate form) and G-Theory/D-Study on the easyCBM reading measures, grades 1-5. Data were gathered in the spring of 2011 from the convenience sample of students nested within classrooms at a medium-sized school district in the Pacific Northwest. Due to…
ERIC Educational Resources Information Center
Lai, Cheng-Fei; Park, Bitnara Jasmine; Anderson, Daniel; Alonzo, Julie; Tindal, Gerald
2012-01-01
This technical report is one in a series of five describing the reliability (test/retest and alternate form) and G-Theory/D-Study research on the easyCBM reading measures, grades 1-5. Data were gathered in the spring of 2011 from a convenience sample of students nested within classrooms at a medium-sized school district in the Pacific Northwest.…
ERIC Educational Resources Information Center
Park, Bitnara Jasmine; Anderson, Daniel; Alonzo, Julie; Lai, Cheng-Fei; Tindal, Gerald
2012-01-01
This technical report is one in a series of five describing the reliability (test/retest and alternate form) and G-Theory/D-Study research on the easyCBM reading measures, grades 1-5. Data were gathered in the spring of 2011 from a convenience sample of students nested within classrooms at a medium-sized school district in the Pacific Northwest.…
A database for propagation models
NASA Technical Reports Server (NTRS)
Kantak, Anil V.; Suwitra, Krisjani; Le, Choung
1994-01-01
A database of various propagation phenomena models that can be used by telecommunications systems engineers to obtain parameter values for systems design is presented. This is an easy-to-use tool and is currently available for either a PC using Excel software under Windows environment or a Macintosh using Excel software for Macintosh. All the steps necessary to use the software are easy and many times self-explanatory; however, a sample run of the CCIR rain attenuation model is presented.
Evaluation of the accuracy of the EasyTest™ malaria Pf/Pan Ag, a rapid diagnostic test, in Uganda.
Chong, Chom-Kyu; Cho, Pyo Yun; Na, Byoung-Kuk; Ahn, Seong Kyu; Kim, Jin Su; Lee, Jin-Soo; Lee, Sung-Keun; Han, Eun-Taek; Kim, Hak-Yong; Park, Yun-Kyu; Cha, Seok Ho; Kim, Tong-Soo
2014-10-01
In recent years, rapid diagnostic tests (RDTs) have been widely used for malaria detection, primarily because of their simple operation, fast results, and straightforward interpretation. The Asan EasyTest™ Malaria Pf/Pan Ag is one of the most commonly used malaria RDTs in several countries, including Korea and India. In this study, we tested the diagnostic performance of this RDT in Uganda to evaluate its usefulness for field diagnosis of malaria in this country. Microscopic and PCR analyses, and the Asan EasyTest™ Malaria Pf/Pan Ag rapid diagnostic test, were performed on blood samples from 185 individuals with suspected malaria in several villages in Uganda. Compared to the microscopic analysis, the sensitivity of the RDT to detect malaria infection was 95.8% and 83.3% for Plasmodium falciparum and non-P. falciparum, respectively. Although the diagnostic sensitivity of the RDT decreased when parasitemia was ≤500 parasites/µl, it showed 96.8% sensitivity (98.4% for P. falciparum and 93.8% for non-P. falciparum) in blood samples with parasitemia ≥100 parasites/µl. The specificity of the RDT was 97.3% for P. falciparum and 97.3% for non-P. falciparum. These results collectively suggest that the accuracy of the Asan EasyTest™ Malaria Pf/Pan Ag makes it an effective point-of-care diagnostic tool for malaria in Uganda.
Evaluation of the Accuracy of the EasyTest™ Malaria Pf/Pan Ag, a Rapid Diagnostic Test, in Uganda
Chong, Chom-Kyu; Cho, Pyo Yun; Na, Byoung-Kuk; Ahn, Seong Kyu; Kim, Jin Su; Lee, Jin-Soo; Lee, Sung-Keun; Han, Eun-Taek; Kim, Hak-Yong; Park, Yun-Kyu; Cha, Seok Ho
2014-01-01
In recent years, rapid diagnostic tests (RDTs) have been widely used for malaria detection, primarily because of their simple operation, fast results, and straightforward interpretation. The Asan EasyTest™ Malaria Pf/Pan Ag is one of the most commonly used malaria RDTs in several countries, including Korea and India. In this study, we tested the diagnostic performance of this RDT in Uganda to evaluate its usefulness for field diagnosis of malaria in this country. Microscopic and PCR analyses, and the Asan EasyTest™ Malaria Pf/Pan Ag rapid diagnostic test, were performed on blood samples from 185 individuals with suspected malaria in several villages in Uganda. Compared to the microscopic analysis, the sensitivity of the RDT to detect malaria infection was 95.8% and 83.3% for Plasmodium falciparum and non-P. falciparum, respectively. Although the diagnostic sensitivity of the RDT decreased when parasitemia was ≤500 parasites/µl, it showed 96.8% sensitivity (98.4% for P. falciparum and 93.8% for non-P. falciparum) in blood samples with parasitemia ≥100 parasites/µl. The specificity of the RDT was 97.3% for P. falciparum and 97.3% for non-P. falciparum. These results collectively suggest that the accuracy of the Asan EasyTest™ Malaria Pf/Pan Ag makes it an effective point-of-care diagnostic tool for malaria in Uganda. PMID:25352698
Jia, Jing; Liang, Xiaojing; Wang, Licheng; Guo, Yong; Liu, Xia; Jiang, Shengxiang
2013-12-13
A nanoporous array anodic titanium-supported co-polymeric ionic liquids (NAAT/PILs) solid-phase microextraction (SPME) fiber was prepared in situ on the titanium wire. NAAT was selected as the substrate, in view of its high surface-to-volume ratio, easy preparation, mechanical stability, and rich titanol groups on its surface which can anchor silica coupling agent containing vinyl and then introduce ionic liquid copolymers as sorbents. In this work, 1-vinyl-3-nonanol imidazolium bromide ([C9OHVIm]Br) and 1,4-di(3-vinylimidazolium) butane dibromide ([(VIM)2C4]2[Br]) were synthesized and used as monomer and crosslinker, respectively. Extraction properties of the NAAT/PILs fiber for polar alcohols and volatile fatty acids (VFAs) in aqueous matrix were examined using gaseous sampling-SPME (GS-SPME) and headspace SPME (HS-SPME) mode, respectively. Combining the superior properties of NAAT substrate and the strong hydrogen bond interaction of PILs to polar compounds, the NAAT/PILs SPME fiber showed much higher adsorption affinity to aliphatic alcohols than bare NAAT and pure PILs fibers. The detection limits (LOD) of established GS-SPME-GC-FID method are in the range of 0.35-17.30ngL(-1) with a linear range from 0.01 to 500ngmL(-1). Also, it showed high extraction performance toward volatile fatty acids (VFAs) compounds from aqueous matrix. Under the optimized SPME conditions, wide linear ranges were obtained with correlation coefficients (R(2)) greater than 0.99 and limits of detection were in the range of 0.85-8.74ngL(-1). Moreover, real-world samples were analyzed and good results were obtained. Copyright © 2013. Published by Elsevier B.V.
Teaching Techniques: Give or Take? Test Review in the ESL/EFL Classroom
ERIC Educational Resources Information Center
Mermelstein, Aaron David
2016-01-01
This article describes "Give or Take?", a fun game that teachers can use to review vocabulary in the English as a second language or foreign language (ESL/EFL) classroom. This game is easy to prepare, and it is a fun and efficient way to review for quizzes or larger midterm or final exams. It can be adapted to almost any grade level or…
How Can Schools Address America's Marriage Crisis? Prepare Young People for Rewarding Careers
ERIC Educational Resources Information Center
Petrilli, Michael P.
2015-01-01
There are no obvious or easy prescriptions for reversing the trends of the familial challenges that have grown deeper and wider in the last fifty years in regard to the number of babies born to unwed mothers, with the majority of all children born to women in their 20s. This article discusses the challenges regarding the marriage crisis in…
ERIC Educational Resources Information Center
Vivian, Rebecca; Falkner, Katrina; Falkner, Nickolas
2014-01-01
England and Australia have introduced new learning areas, teaching computer science to children from the first year of school. This is a significant milestone that also raises a number of big challenges: the preparation of teachers and the development of resources" at a national scale." Curriculum change is not easy for teachers, in any…
EXFILE: A program for compiling irradiation data on UN and UC fuel pins
NASA Technical Reports Server (NTRS)
Mayer, J. T.; Smith, R. L.; Weinstein, M. B.; Davison, H. W.
1973-01-01
A FORTRAN-4 computer program for handling fuel pin data is described. Its main features include standardized output, easy access for data manipulation, and tabulation of important material property data. An additional feature allows simplified preparation of input decks for a fuel swelling computer code (CYGRO-2). Data from over 300 high temperature nitride and carbide based fuel pin irradiations are listed.
ERIC Educational Resources Information Center
Peacock, Nicola; Harrison, Neil
2009-01-01
A recent aspect of U.K. higher education has been the internationalisation of university campuses, driven by a rapid increase in student numbers from overseas and growing pressure to prepare all students for global careers. It is often assumed by policy makers that the benefits of an internationalised university will include opportunities for…
Tips for Kids: Lower Your Risk for Type 2 Diabetes
ERIC Educational Resources Information Center
US Department of Health and Human Services, 2005
2005-01-01
Today, more kids have type 2 diabetes than ever before. This colorful, easy-to-read tip sheet encourages young people to take steps to lower their risk for type 2 diabetes. A list of warning signs and a healthy eating guide is offered, along with a list of websites to learn more. [This brochure was prepared by the Department of Health and Human…
Common Core Literacy Lesson Plans: Ready-to-Use Resources, 9-12
ERIC Educational Resources Information Center
Davis, Lauren
2013-01-01
Schools nationwide are transitioning to the Common Core--our advice to you: Be prepared, but don't go it alone! Our new book, "Common Core Literacy Lesson Plans: Ready-to-Use Resources, 9-12," shows you that teaching the Common Core State Standards in high school doesn't have to be intimidating! This easy-to-use guide meets the particular needs of…
ERIC Educational Resources Information Center
Cunningham, Alisa F.; Erisman, Wendy; Looney, Shannon M.
2007-01-01
The importance of going to college has increased in the context of global competition and continuing stratification in society. Many strides have been made in encouraging students and parents to believe in the value of higher education, but the process of preparing for and applying to college is not easy. It requires making a variety of complex…
Empowering the managed care consumer: not as easy as it sounds.
Korczyk, S M; Witte, H A
2000-01-01
Managed care remains one of the most highly publicized issues in employee benefits, with its accompanying controversy causing concern to the consumer and the employer. The authors of this article discuss the very basic things consumers of health benefits should know about their plans in order to be prepared, as well as what they should reasonably expect from employers that sponsor the plans.
A brief introduction to the word associate test
Verplanck, William S.
1992-01-01
An examination format assessing the intraverbal repertoire of individuals in psychology is described and results using it reported. The Associate Test is easy to prepare, to take, and to grade. Its reliability measures are satisfactory; its ability to predict later behavior is reported upon. The Associate Test is computer friendly, and its methods can be applied for examination in any field, and at any level. PMID:22477050
The Sol-Gel-Xerogel Transition
1993-11-01
basic pH. Bioactive sol-gel glasses obtained by a surface adsorption of trypsin to a readymade xerogel were also completley * L...presence of siloxane chains and hydrophobic methyl groups an easy film deposition on glass sheets can be obtained. Rhodamine 6G and Coumarin 4 were...Research Proposal was prepared (early 1989) have witnessed a tremendous, almost explosive, progress in the field of organically doped sol-gel glasses
Crystal field effects in the intermetallic R Ni3Ga9 (R =Tb , Dy, Ho, and Er) compounds
NASA Astrophysics Data System (ADS)
Silva, L. S.; Mercena, S. G.; Garcia, D. J.; Bittar, E. M.; Jesus, C. B. R.; Pagliuso, P. G.; Lora-Serrano, R.; Meneses, C. T.; Duque, J. G. S.
2017-04-01
In this paper, we report temperature-dependent magnetic susceptibility, electrical resistivity, and heat-capacity experiments in the family of intermetallic compounds R Ni3Ga9 (R = Tb, Dy, Ho, and Er). Single-crystalline samples were grown using Ga self-flux method. These materials crystallize in a trigonal ErNi3Al9 -type structure with space group R 32 . They all order antiferromagnetically with TN<20 K . The anisotropic magnetic susceptibility presents large values of the ratio χeasy/χhard indicating strong crystalline electric-field (CEF) effects. The evolution of the crystal-field scheme for each R was analyzed in detail by using a spin model including anisotropic nearest-neighbor Ruderman-Kittel-Kasuya-Yosida interaction and the trigonal CEF Hamiltonian. Our analysis allows one to understand the distinct direction of the ordered moments along the series—the Tb-, Dy-, and Ho-based compounds have the ordered magnetic moments in the easy ab plane and the Er sample magnetization easy axis is along the c ̂ direction.
Kapperud, G; Vardund, T; Skjerve, E; Hornes, E; Michaelsen, T E
1993-01-01
A two-step polymerase chain reaction (PCR) procedure with two nested pairs of primers specific for the yadA gene of Yersinia enterocolitica was developed. The PCR assay identified all common pathogenic serogroups (O:3, O:5,27, O:8, O:9, O:13, and O:21) from three continents and differentiated pathogenic Y. enterocolitica from Y. pseudotuberculosis and from a variety of nonpathogenic yersiniae representing 25 serogroups and four species. The performance of the method was evaluated with seeded food and water samples. We compared two procedures for sample preparation prior to PCR: one was based on immunomagnetic separation of the target bacteria from the sample, using magnetic particles coated with immunoglobulin antibodies to Y. enterocolitica serogroup O:3, and the other method consisted of a series of centrifugation steps combined with proteinase treatment. Regardless of the method used, the PCR assay was capable of detecting 10 to 30 CFU/g of meat in 10(6)-fold excess of indigenous bacteria. When the samples were enriched overnight in a nonselective medium, the sensitivity was increased to approximately 2 CFU/g, except for samples with an extremely high background flora (> 10(7) CFU/g). We compared gel electrophoretic detection of PCR products with a colorimetric detection method designated DIANA (detection of immobilized amplified nucleic acids), which enabled easy visualization of amplified fragments in a microtiter plate format with an optical density reader. DIANA and gel electrophoresis showed complete concordance in their discrimination between positive and negative samples. The combination of immunomagnetic separation, nested PCR, and DIANA makes possible the development of a fully automated analytic process which requires a minimum of laboratory manipulations. Images PMID:8215366
Asakura, Kota; Azechi, Takuya; Sasano, Hiroshi; Matsui, Hidehito; Hanaki, Hideaki; Miyazaki, Motoyasu; Takata, Tohru; Sekine, Miwa; Takaku, Tomoiku; Ochiai, Tomonori; Komatsu, Norio; Shibayama, Keigo; Katayama, Yuki; Yahara, Koji
2018-01-01
Vancomycin-intermediately resistant Staphylococcus aureus (VISA) and heterogeneous VISA (hVISA) are associated with treatment failure. hVISA contains only a subpopulation of cells with increased minimal inhibitory concentrations, and its detection is problematic because it is classified as vancomycin-susceptible by standard susceptibility testing and the gold-standard method for its detection is impractical in clinical microbiology laboratories. Recently, a research group developed a machine-learning classifier to distinguish VISA and hVISA from vancomycin-susceptible S. aureus (VSSA) according to matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) data. Nonetheless, the sensitivity of hVISA classification was found to be 76%, and the program was not completely automated with a graphical user interface. Here, we developed a more accurate machine-learning classifier for discrimination of hVISA from VSSA and VISA among MRSA isolates in Japanese hospitals by means of MALDI-TOF MS data. The classifier showed 99% sensitivity of hVISA classification. Furthermore, we clarified the procedures for preparing samples and obtaining MALDI-TOF MS data and developed all-in-one software, hVISA Classifier, with a graphical user interface that automates the classification and is easy for medical workers to use; it is publicly available at https://github.com/bioprojects/hVISAclassifier. This system is useful and practical for screening MRSA isolates for the hVISA phenotype in clinical microbiology laboratories and thus should improve treatment of MRSA infections.
Asakura, Kota; Azechi, Takuya; Sasano, Hiroshi; Matsui, Hidehito; Hanaki, Hideaki; Miyazaki, Motoyasu; Takata, Tohru; Sekine, Miwa; Takaku, Tomoiku; Ochiai, Tomonori; Komatsu, Norio; Shibayama, Keigo
2018-01-01
Vancomycin-intermediately resistant Staphylococcus aureus (VISA) and heterogeneous VISA (hVISA) are associated with treatment failure. hVISA contains only a subpopulation of cells with increased minimal inhibitory concentrations, and its detection is problematic because it is classified as vancomycin-susceptible by standard susceptibility testing and the gold-standard method for its detection is impractical in clinical microbiology laboratories. Recently, a research group developed a machine-learning classifier to distinguish VISA and hVISA from vancomycin-susceptible S. aureus (VSSA) according to matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) data. Nonetheless, the sensitivity of hVISA classification was found to be 76%, and the program was not completely automated with a graphical user interface. Here, we developed a more accurate machine-learning classifier for discrimination of hVISA from VSSA and VISA among MRSA isolates in Japanese hospitals by means of MALDI-TOF MS data. The classifier showed 99% sensitivity of hVISA classification. Furthermore, we clarified the procedures for preparing samples and obtaining MALDI-TOF MS data and developed all-in-one software, hVISA Classifier, with a graphical user interface that automates the classification and is easy for medical workers to use; it is publicly available at https://github.com/bioprojects/hVISAclassifier. This system is useful and practical for screening MRSA isolates for the hVISA phenotype in clinical microbiology laboratories and thus should improve treatment of MRSA infections. PMID:29522576
Influence of Superhydrophobic Properties on Deicing
NASA Astrophysics Data System (ADS)
Nazhipkyzy, M.; Mansurov, Z. A.; Amirfazli, A.; Esbosin, A.; Temirgaliyeva, T. S.; Lesbayev, B. T.; Aliyev, E. T.; Prikhodko, N. G.
2016-11-01
Nowadays the creation of anti-icing, or deicing, surfaces is one of the most important problems, as such surfaces are widely used in aeronautics, wind turbines, and telecommunication antennas. In this paper, we focus mainly on reducing the ice adhesion forces and easy ice removal, once ice has formed. Removal of a liquid from a surface can be provided by modification of the surface wettability by means of applying superhydrophobic coatings. Such coatings are water-resistant, i.e., are characterized by low water adhesion forces. To study the impact of superhydrophobic coatings, tests were performed on the surface of a wing in a wind tunnel. By spraying Teflon and polyphenylene sulfide (PPS) on the wing, we obtained a superhydrophobic film. This film has a structure that provides superhydrophobic properties, so that the wetting angle is above 140°. A comparison of the resulting surface with a clean Teflon one shows that adhesion of the Teflon + PPS mixture to an aluminum surface is five times higher. We also investigate the degree of ice formation on the surfaces of simple and superhydrophobic aircraft wings at a temperature of -18°C. It was shown that ice was formed on a simple wing within 40 s and on a superhydrophobic wing within 25 s. When the simple wing with a mass of 23 g was inserted into the wind tunnel, its mass reached 50 g, and for a superhydrophobic wing with a mass of 26 g the latter reached 42 g. The sample of the airfoil wing we prepared has a low adhesion, which helps in easy ice removal.
An easy “SteamDrop” method for high quality plant chromosome preparation
2014-01-01
Background The chromosome preparation is a crucial step for obtaining satisfactory results in molecular cytogenetic researches. The preparation of plant chromosomes for molecular cytogenetic purposes remains a challenge for some species. In contrast to human chromosome preparation, the processes occurring during plant chromosome preparation and causing chromosome spreading are still poorly understood. Results We studied the dynamics of plant chromosome spreading after dropping cell suspension on slides. We showed that steam stimulates cytoplasm hydrolysis and rapid chromosome spreading and that chromosomes stretch during this chromosome spreading. Based on these observations, we developed a novel method, named “SteamDrop”, for the preparation of well-spread mitotic and pachytene chromosomes and successfully used it for 28 plant species with large and small chromosomes. We applied cell suspensions in ethanol instead of the commonly used ethanol/acetic acid fixative. Mitotic and meiotic chromosomes prepared via “SteamDrop” were used in fluorescent in situ hybridization (FISH) experiments with repetitive and unique DNA probes. Long storage of cell suspensions in ethanol did not impair the quality of chromosome preparations. Conclusion The SteamDrop procedure provides a robust and routine method for high quality plant chromosome preparations. The method can be applied for metaphase as well as pachytene chromosome preparation in wide range of species. The chromosomes prepared by SteamDrop are well suitable for repetitive and unique DNA visualization. PMID:24602284
The structural and optical constants of Ag2S semiconductor nanostructure in the Far-Infrared.
Zamiri, Reza; Abbastabar Ahangar, Hossein; Zakaria, Azmi; Zamiri, Golnoosh; Shabani, Mehdi; Singh, Budhendra; Ferreira, J M F
2015-01-01
In this paper a template-free precipitation method was used as an easy and low cost way to synthesize Ag2S semiconductor nanoparticles. The Kramers-Kronig method (K-K) and classical dispersion theory was applied to calculate the optical constants of the prepared samples, such as the reflective index n(ω) and dielectric constant ε(ω) in Far-infrared regime. Nanocrystalline Ag2S was synthesized by a wet chemical precipitation method. Ag2S nanoparticle was characterized by X-ray diffraction, Scanning Electron Microscopy, UV-visible, and FT-IR spectrometry. The refinement of the monoclinic β-Ag2S phase yielded a structure solution similar to the structure reported by Sadanaga and Sueno. The band gap of Ag2S nanoparticles is around 0.96 eV, which is in good agreement with previous reports for the band gap energy of Ag2S nanoparticles (0.9-1.1 eV). The crystallite size of the synthesized particles was obtained by Hall-Williamson plot for the synthesized Ag2S nanoparticles and it was found to be 217 nm. The Far-infrared optical constants of the prepared Ag2S semiconductor nanoparticles were evaluated by means of FTIR transmittance spectra data and K-K method. Graphical abstractThe Far-infrared optical constants of Ag2S semiconductor nanoparticles.
Ebner, T; Shebl, O; Moser, M; Mayer, R B; Arzt, W; Tews, G
2011-01-01
Sperm DNA fragmentation is increased in poor-quality semen samples and correlates with failed fertilization, impaired preimplantation development and reduced pregnancy outcome. Common sperm preparation techniques may reduce the percentage of strandbreak-positive spermatozoa, but, to date, there is no reliable approach to exclusively accumulate strandbreak-free spermatozoa. To analyse the efficiency of special sperm selection chambers (Zech-selectors made of glass or polyethylene) in terms of strandbreak reduction, 39 subfertile men were recruited and three probes (native, density gradient and Zech-selector) were used to check for strand breaks using the sperm chromatin dispersion test. The mean percentage of affected spermatozoa in the ejaculate was 15.8 ± 7.8% (range 5.0–42.1%). Density gradient did not significantly improve the quality of spermatozoa selected(14.2 ± 7.0%). However, glass chambers completely removed 90% spermatozoa showing strand breaks and polyethylene chambers removed 76%. Both types of Zech-selectors were equivalent in their efficiency, significantly reduced DNA damage (P < 0.001) and,with respect to this, performed better than density gradient centrifugation (P < 0.001). As far as is known, this is the first report ona sperm preparation technique concentrating spermatozoa unaffected in terms of DNA damage. The special chambers most probably select for sperm motility and/or maturity. Copyright © 2010 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Foley, Henry C.
1990-01-01
The objective of this research is to define the methodology for the preparation and characterization of new carbon-based molecular sieves with composite structures. Carbon molecular sieves have found increasing application in the field of separation and purification of gases. These materials are relatively easy to prepare and their surfaces can be modified to some extent. It is expected that by combining inorganic oxides with the carbonaceous structure one can begin to design composite materials with a wider range of possible chemical and physical properties. In this way, the IOM-CMS materials may confer distinct advantages over pure carbon molecular sieves, not just for separation, but also for catalysis. The most recent results in the design and characterization of these IOM-CMS materials are reviewed and summarized. Directions for further research are also presented.
Li, J; Cheong, K L; Zhao, J; Hu, D J; Chen, X Q; Qiao, C F; Zhang, Q W; Chen, Y W; Li, S P
2013-09-20
A fast protein liquid chromatography coupled with refractive index detection (FPLC-RID) method was firstly developed for preparation and purification of fructooligosaccharides with different degree of polymerization from burdock, Arctium lappa. After extraction with 60% ethanol and decolorization with MCI gel CHP20P, total fructooligosaccharides were purified on Bio-Gel P-2 column eluted with water at the flow rate of 0.3 ml/min, which was the optimized conditions. The obtained fructooligosaccharides with degree of polymerization of 3-9 were identified based on their methylation analysis, MS and NMR data. This method has the advantages of high automation, good recovery and easy performance, which could be used for preparation of FOS from other sources, as well as other targeted compounds without UV absorbance. Copyright © 2013 Elsevier B.V. All rights reserved.
Improved Dielectric Properties via Mechano-Chemical Activation in Ba0.80Pb0.20TiO3 Ceramics
NASA Astrophysics Data System (ADS)
Kumar, Parveen; Rani, Renu; Singh, Sangeeta; Juneja, J. K.; Prakash, Chandra; Raina, K. K.
2011-12-01
The present report is about the preparation and dielectric properties of commonly used Ba0.80Pb0.20TiO3 (BPT) ferroelectric ceramic via Mechano-Chemical Activation (MCA). Results were compared by the BPT sample prepared by conventional solid state method. The BPT sample prepared via MCA technique was found to have decreased tetragonality, dielectric constant value (ɛRT = 450 and ɛmax = 6170) approximately double the value for sample prepared by conventional method (ɛRT = 260 and ɛmax = 3275). Also, the sample prepared by MCA was found to be less frequency dependent. Thus, the BPT sample prepared via MCA is more suitable for capacitor applications requiring lesser frequency dependency than the conventionally prepared BPT sample.
ERIC Educational Resources Information Center
Park, Bitnara Jasmine; Anderson, Daniel; Alonzo, Julie; Lai, Cheng-Fei; Tindal, Gerald
2012-01-01
This technical report is one in a series of five describing the reliability (test/retest and alternate form) and G-Theory/D-Study research on the easyCBM reading measures, grades 1-5. Data were gathered in the spring of 2011 from a convenience sample of students nested within classrooms at a medium-sized school district in the Pacific Northwest.…
Novel immunoassay formats for integrated microfluidic circuits: diffusion immunoassays (DIA)
NASA Astrophysics Data System (ADS)
Weigl, Bernhard H.; Hatch, Anson; Kamholz, Andrew E.; Yager, Paul
2000-03-01
Novel designs of integrated fluidic microchips allow separations, chemical reactions, and calibration-free analytical measurements to be performed directly in very small quantities of complex samples such as whole blood and contaminated environmental samples. This technology lends itself to applications such as clinical diagnostics, including tumor marker screening, and environmental sensing in remote locations. Lab-on-a-Chip based systems offer many *advantages over traditional analytical devices: They consume extremely low volumes of both samples and reagents. Each chip is inexpensive and small. The sampling-to-result time is extremely short. They perform all analytical functions, including sampling, sample pretreatment, separation, dilution, and mixing steps, chemical reactions, and detection in an integrated microfluidic circuit. Lab-on-a-Chip systems enable the design of small, portable, rugged, low-cost, easy to use, yet extremely versatile and capable diagnostic instruments. In addition, fluids flowing in microchannels exhibit unique characteristics ('microfluidics'), which allow the design of analytical devices and assay formats that would not function on a macroscale. Existing Lab-on-a-chip technologies work very well for highly predictable and homogeneous samples common in genetic testing and drug discovery processes. One of the biggest challenges for current Labs-on-a-chip, however, is to perform analysis in the presence of the complexity and heterogeneity of actual samples such as whole blood or contaminated environmental samples. Micronics has developed a variety of Lab-on-a-Chip assays that can overcome those shortcomings. We will now present various types of novel Lab- on-a-Chip-based immunoassays, including the so-called Diffusion Immunoassays (DIA) that are based on the competitive laminar diffusion of analyte molecules and tracer molecules into a region of the chip containing antibodies that target the analyte molecules. Advantages of this technique are a reduction in reagents, higher sensitivity, minimal preparation of complex samples such as blood, real-time calibration, and extremely rapid analysis.
Application of Raman spectroscopy technology to studying Sudan I
NASA Astrophysics Data System (ADS)
Li, Gang; Zhang, Guoping; Chen, Chen
2006-06-01
Being an industrial dye, the Sudan I may have a toxic effect after oral intake on the body, and has recently been shown to cause cancer in rats, mice and rabbits. Because China and some other countries have detected the Sudan I in samples of the hot chilli powder and the chilli products, it is necessary to study the characteristics of this dye. As one kind of molecule scattering spectroscopy, Raman spectroscopy is characterized by the frequency excursion caused by interactions of molecules and photons. The frequency excursion reflects the margin between certain two vibrational or rotational energy states, and shows the information of the molecule. Because Raman spectroscopy can provides quick, easy, reproducible, and non-destructive analysis, both qualitative and quantitative, with no sample preparation required, Raman spectroscopy has been a particularly promising technique for analyzing the characteristics and structures of molecules, especially organic ones. Now, it has a broad application in biological, chemical, environmental and industrial applications. This paper firstly introduces Sudan I dye and the Raman spectroscopy technology, and then describes its application to the Sudan I. Secondly, the fingerprint spectra of the Sudan I are respectively assigned and analyzed in detail. Finally, the conclusion that the Raman spectroscopy technology is a powerful tool to determine the Sudan I is drawn.
Rzeppa, S; Heinrich, G; Hemmersbach, P
2015-01-01
Improvements in doping analysis can be effected by speeding up analysis time and extending the detection time. Therefore, direct detection of phase II conjugates of doping agents, especially anabolic androgenic steroids (AAS), is proposed. Besides direct detection of conjugates with glucuronic acid, the analysis of sulfate conjugates, which are usually not part of the routine doping control analysis, can be of high interest. Sulfate conjugates of methandienone and methyltestosterone metabolites have already been identified as long-term metabolites. This study presents the synthesis of sulfate conjugates of six commonly used AAS and their metabolites: trenbolone, nandrolone, boldenone, methenolone, mesterolone, and drostanolone. In the following these sulfate conjugates were used for development of a fast and easy analysis method based on sample preparation using solid phase extraction with a mixed-mode sorbent and detection by high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS). Validation demonstrated the suitability of the method with regard to the criteria given by the technical documents of the World Anti-Doping Agency (WADA). In addition, suitability has been proven by successful detection of the synthesized sulfate conjugates in excretion urines and routine doping control samples. Copyright © 2015 John Wiley & Sons, Ltd.
Fernandes, Virgínia C; Domingues, Valentina F; Mateus, Nuno; Delerue-Matos, Cristina
2012-11-01
Pesticides are among the most widely used chemicals in the world. Because of the widespread use of agricultural chemicals in food production, people are exposed to low levels of pesticide residues through their diets. Scientists do not yet have a total understanding of the health effects of these pesticide residues. This work aims to determine differences in terms of pesticide residue content in Portuguese strawberries grown using different agriculture practices. The Quick, Easy, Cheap, Effective, Rugged, and Safe sample preparation method was conducted and shown to have good performance for multiclass pesticides extraction in strawberries. The screening of 25 pesticides residue was performed by gas chromatography-tandem mass spectrometry. In quantitative validation, acceptable performances were achieved with recoveries of 70-120 and <12 % residual standard deviation for 25 pesticides. Good linearity was obtained for all the target compounds, with highly satisfactory repeatability. The limits of detection were in the range of 0.1-28 μg/kg. The method was applied to analyze strawberry samples from organic and integrated pest management (IPM) practices harvested in 2009-2010. The results showed the presence of fludioxonil, bifenthrin, mepanipyrim, tolylfluanid, cyprodinil, tetraconazole, and malathion when using IPM below the maximum residue levels.
Intrinsic origin of two-dimensional electron gas at the (001) surface of SrTiO3
NASA Astrophysics Data System (ADS)
Delugas, Pietro; Fiorentini, Vincenzo; Mattoni, Alessandro; Filippetti, Alessio
2015-03-01
It is generally assumed that two-dimensional electron gas (2DEG) recently observed at the (001) SrTiO3 surface can be solely derived by oxygen vacancies introduced during ultrahigh vacuum annealing or through ultraviolet irradiation exposure. However, 2DEG entirely due to defect formation may be at odds with the characteristics of high mobility and easy field-effect manipulation required for applications; to that aim, an intrinsic formation mechanism should be preferred. Using advanced ab initio simulations we give evidence that 2DEG at the (001) SrTiO3 surface may even result from purely intrinsic properties of the pristine surface, provided that the surface is SrO terminated. The key concept is that the SrO termination is electron-attractive as a consequence of both the surface-induced polarity and the specific electronic reconstruction, whereas the TiO2 termination is electron-repulsive. It follows that in vacuum-cleaved samples where both terminations are present, 2DEG can result from the structurally ordered superposition of the two kinds of domain, even in the absence of any extrinsic source. On the other hand, in etching-prepared single-terminated TiO2 samples 2DEG should be assumed as entirely derived by extrinsic factors.
Dual-wavelength external cavity laser device for fluorescence suppression in Raman spectroscopy
NASA Astrophysics Data System (ADS)
Zhang, Xuting; Cai, Zhijian; Wu, Jianhong
2017-10-01
Raman spectroscopy has been widely used in the detection of drugs, pesticides, explosives, food additives and environmental pollutants, for its characteristics of fast measurement, easy sample preparation, and molecular structure analyzing capability. However, fluorescence disturbance brings a big trouble to these applications, with strong fluorescence background covering up the weak Raman signals. Recently shifted excitation Raman difference spectroscopy (SERDS) not only can completely remove the fluorescence background, but also can be easily integrated into portable Raman spectrometers. Usually, SERDS uses two lasers with small wavelength gap to excite the sample, then acquires two spectra, and subtracts one to the other to get the difference spectrum, where the fluorescence background will be rejected. So, one key aspects of successfully applying SERDS method is to obtain a dual-wavelength laser source. In this paper, a dual-wavelength laser device design based on the principles of external cavity diode laser (ECDL) is proposed, which is low-cost and compact. In addition, it has good mechanical stability because of no moving parts. These features make it an ideal laser source for SERDS technique. The experiment results showed that the device can emit narrow-spectral-width lasers of two wavelengths, with the gap smaller than 2 nanometers. The laser power corresponding to each wavelength can be up to 100mW.
NASA Astrophysics Data System (ADS)
Fauzan, A.; Praseptiangga, D.; Hartanto, R.; Pujiasmanto, B.
2018-01-01
The purpose of this study was to characterize the chemical compounds of Adenostemma lavenia (L.) Kuntze (Al) and Adenostemma platyphyllum Cass (Ap) using Pyrolysis-gas chromatography/mass spectrometry (Py-GCMS) and proximate analysis. Two species of Adenostemma samples (roots, stem and leaves) about 1 mg was pyrolyzed directly at the optimum temperature of 600°C. Py-GCMS was relatively fast, easy to use and without samples preparation and identification of the chemical compounds was carried out by comparison of the mass spectra obtained with those stored in Wiley 7th libraries. The data of proximate analysis were statistically analysed using Friedman test followed and hierarchical cluster analysis (HCA) for data of Py-GCMS. The result of proximate analysis showed that A. lavenia (L.) Kuntze (Al) and A. platyphyllum Cass (Ap) contained 8.27% (Al) and 9.18% (Ap) of water, 11.52% (Al) and 17.84% (Ap) of protein, 5.67% (Al) and 6.33% (Ap) of fat, and 17.32% (Al) and 19.94 (Ap) of ash. Amines, aldehydes, fatty acids, terpenoids-steroids, alkaloids, aromatic and aliphatic hydrocarbons, phenolic, and oligopeptides as part of 125 chemical compounds of each species are identified by Py-GCMS analysis. Hierarchical cluster analysis of pyrolysis products indicate not similitary of major chemical compounds of two Adenostemma species.
Recent advances in applications of nanomaterials for sample preparation.
Xu, Linnan; Qi, Xiaoyue; Li, Xianjiang; Bai, Yu; Liu, Huwei
2016-01-01
Sample preparation is a key step for qualitative and quantitative analysis of trace analytes in complicated matrix. Along with the rapid development of nanotechnology in material science, numerous nanomaterials have been developed with particularly useful applications in analytical chemistry. Benefitting from their high specific areas, increased surface activities, and unprecedented physical/chemical properties, the potentials of nanomaterials for rapid and efficient sample preparation have been exploited extensively. In this review, recent progress of novel nanomaterials applied in sample preparation has been summarized and discussed. Both nanoparticles and nanoporous materials are evaluated for their unusual performance in sample preparation. Various compositions and functionalizations extended the applications of nanomaterials in sample preparations, and distinct size and shape selectivity was generated from the diversified pore structures of nanoporous materials. Such great variety make nanomaterials a kind of versatile tools in sample preparation for almost all categories of analytes. Copyright © 2015 Elsevier B.V. All rights reserved.
Kanavi, Mozhgan Rezaei; Javadi, Mohammad Ali; Javadi, Fatemeh; Chamani, Tahereh
2014-09-01
To describe the technique and the results of the preparation of pre-cut corneas for Descemet's stripping automated endothelial keratoplasty (DSAEK) during a 3-year period at the Central Eye Bank of Iran (CEBI). The method of preparation of pre-cut corneas from donated whole globes at the CEBI is described and the frequency and percentage of pre-cut corneas prepared for DSAEK, between April 2009 and March 2012, are specified. Moreover, post-operative reports are reviewed for any complaints about using pre-cut tissues for DSAEK. Out of the 1,518 donated whole globes appropriate for DSAEK, 1,478 (97.4 %) pre-cut corneas were successfully prepared. The method of preparation failed in 40 (2.6 %) cases. Based on the eye bank post-operative reports, thickness of pre-cut tissues for DSAEK was deemed unacceptable in only 6 (0.4 %) cases prior to surgery; five of these were too thick and one was too thin. Preparation of pre-cut corneas, for DSAEK from donated whole globes, in the CEBI is a safe and easy method, with very good preservation of endothelial cells after the preparation of the pre-cut corneas and reduced risks from corneal manipulation.
Stable isotopes can be very useful in large-scale monitoring programs because samples for isotopic analysis are easy to collect, and isotopes integrate information about complex processes such as evaporation from water isotopes and denitrification from nitrogen isotopes. Traditi...
Huang, Xinhua; Kim, Seok; Heo, Min Seon; Kim, Ji Eun; Suh, Hongsuk; Kim, Il
2013-10-01
An easy template-free approach to the fabrication of pure carbon microspheres has been achieved via direct pyrolysis of as-prepared polyaromatic hydrocarbons including polynaphthalene and polypyrene. The polyaromatics were synthesized from aromatic hydrocarbons (AHCs) using anhydrous zinc chloride as the Friedel-Crafts catalyst and chloromethyl methyl ether as a cross-linker. The experimental results show that the methylene bridges between phenyl rings generate a hierarchical porous polyaromatic precursor to form three-dimensionally (3D) interconnected micro-, meso-, and macroporous networks during carbonization. These hierarchical porous carbon aggregates of spherical carbon spheres exhibit faster ion transport/diffusion behavior and increased surface area usage in electric double-layer capacitors. Furthermore, micropores are present in the 3D interconnected network inside the cross-linked AHC-based carbon microspheres, thus imparting an exceptionally large, electrochemically accessible surface area for charge accumulation.
Mekada, N; Seino, M; Kubota, Y; Nakajima, H
1990-12-01
We propose and demonstrate new practical methods of waveguide end fabrication and fiber attachment for Ti:LiNbO(3) waveguides. We fabricated waveguide endfaces with a cutting machine, which simplifies the manufacture of waveguide devices and provides a low excess loss of 0.3 dB or less. Our proposed fiber attachment method features fibers that protrude slightly from the reinforcement. It provides easy alignment, low excess loss (<0.1 dB), high strength (>600 gf), and high thermal stability (-10 to 60 degrees C). We also developed an easy way to reduce the backreflection from the joint without using anti-reflection coating. Instead, a tapered hemispherical end fiber and an angled waveguide endface are used. Backreflection is easily reduced to less than -30.
The Recent Developments in Sample Preparation for Mass Spectrometry-Based Metabolomics.
Gong, Zhi-Gang; Hu, Jing; Wu, Xi; Xu, Yong-Jiang
2017-07-04
Metabolomics is a critical member in systems biology. Although great progress has been achieved in metabolomics, there are still some problems in sample preparation, data processing and data interpretation. In this review, we intend to explore the roles, challenges and trends in sample preparation for mass spectrometry- (MS-) based metabolomics. The newly emerged sample preparation methods were also critically examined, including laser microdissection, in vivo sampling, dried blood spot, microwave, ultrasound and enzyme-assisted extraction, as well as microextraction techniques. Finally, we provide some conclusions and perspectives for sample preparation in MS-based metabolomics.
Xie, Yian; Liu, Yufeng; Wang, Yaoming; Zhu, Xiaolong; Li, Aimin; Zhang, Lei; Qin, Mingsheng; Lü, Xujie; Huang, Fuqiang
2014-04-28
Low-cost and high-yield preparation of CuInSe2 films is the bottleneck for promising CuInSe2-based thin film solar cells. Here, we developed a simple, safe and cost-effective method using thioacetic acid to fabricate the absorber films of CuIn(S,Se)2 (CISSe). Dissolution of Cu2O and In(OH)3 in thioacetic acid was attributed to the strong coordination ability of S. The adhesive precursor solution can be prepared without any heating, centrifugation and inert gas protection, superior to the previously reported methods. The precursor CISSe layer was easily deposited in air by spin coating to ensure low cost. Uniform and compact CISSe thin films with well-crystallized and pure-phased CISSe grains were obtained after one step annealing. The as-prepared CISSe thin films were successfully applied to solar cells and a energy conversion efficiency of 6.75% was achieved. This facile preparation provides a low-cost and easy method to fabricate Cu-based thin film solar cells.