EBI metagenomics--a new resource for the analysis and archiving of metagenomic data.
Hunter, Sarah; Corbett, Matthew; Denise, Hubert; Fraser, Matthew; Gonzalez-Beltran, Alejandra; Hunter, Christopher; Jones, Philip; Leinonen, Rasko; McAnulla, Craig; Maguire, Eamonn; Maslen, John; Mitchell, Alex; Nuka, Gift; Oisel, Arnaud; Pesseat, Sebastien; Radhakrishnan, Rajesh; Rocca-Serra, Philippe; Scheremetjew, Maxim; Sterk, Peter; Vaughan, Daniel; Cochrane, Guy; Field, Dawn; Sansone, Susanna-Assunta
2014-01-01
Metagenomics is a relatively recently established but rapidly expanding field that uses high-throughput next-generation sequencing technologies to characterize the microbial communities inhabiting different ecosystems (including oceans, lakes, soil, tundra, plants and body sites). Metagenomics brings with it a number of challenges, including the management, analysis, storage and sharing of data. In response to these challenges, we have developed a new metagenomics resource (http://www.ebi.ac.uk/metagenomics/) that allows users to easily submit raw nucleotide reads for functional and taxonomic analysis by a state-of-the-art pipeline, and have them automatically stored (together with descriptive, standards-compliant metadata) in the European Nucleotide Archive.
EBI metagenomics—a new resource for the analysis and archiving of metagenomic data
Hunter, Sarah; Corbett, Matthew; Denise, Hubert; Fraser, Matthew; Gonzalez-Beltran, Alejandra; Hunter, Christopher; Jones, Philip; Leinonen, Rasko; McAnulla, Craig; Maguire, Eamonn; Maslen, John; Mitchell, Alex; Nuka, Gift; Oisel, Arnaud; Pesseat, Sebastien; Radhakrishnan, Rajesh; Rocca-Serra, Philippe; Scheremetjew, Maxim; Sterk, Peter; Vaughan, Daniel; Cochrane, Guy; Field, Dawn; Sansone, Susanna-Assunta
2014-01-01
Metagenomics is a relatively recently established but rapidly expanding field that uses high-throughput next-generation sequencing technologies to characterize the microbial communities inhabiting different ecosystems (including oceans, lakes, soil, tundra, plants and body sites). Metagenomics brings with it a number of challenges, including the management, analysis, storage and sharing of data. In response to these challenges, we have developed a new metagenomics resource (http://www.ebi.ac.uk/metagenomics/) that allows users to easily submit raw nucleotide reads for functional and taxonomic analysis by a state-of-the-art pipeline, and have them automatically stored (together with descriptive, standards-compliant metadata) in the European Nucleotide Archive. PMID:24165880
libChEBI: an API for accessing the ChEBI database.
Swainston, Neil; Hastings, Janna; Dekker, Adriano; Muthukrishnan, Venkatesh; May, John; Steinbeck, Christoph; Mendes, Pedro
2016-01-01
ChEBI is a database and ontology of chemical entities of biological interest. It is widely used as a source of identifiers to facilitate unambiguous reference to chemical entities within biological models, databases, ontologies and literature. ChEBI contains a wealth of chemical data, covering over 46,500 distinct chemical entities, and related data such as chemical formula, charge, molecular mass, structure, synonyms and links to external databases. Furthermore, ChEBI is an ontology, and thus provides meaningful links between chemical entities. Unlike many other resources, ChEBI is fully human-curated, providing a reliable, non-redundant collection of chemical entities and related data. While ChEBI is supported by a web service for programmatic access and a number of download files, it does not have an API library to facilitate the use of ChEBI and its data in cheminformatics software. To provide this missing functionality, libChEBI, a comprehensive API library for accessing ChEBI data, is introduced. libChEBI is available in Java, Python and MATLAB versions from http://github.com/libChEBI, and provides full programmatic access to all data held within the ChEBI database through a simple and documented API. libChEBI is reliant upon the (automated) download and regular update of flat files that are held locally. As such, libChEBI can be embedded in both on- and off-line software applications. libChEBI allows better support of ChEBI and its data in the development of new cheminformatics software. Covering three key programming languages, it allows for the entirety of the ChEBI database to be accessed easily and quickly through a simple API. All code is open access and freely available.
DeGroff, Amy; Carter, Aundrea; Kenney, Kristy; Myles, Zachary; Melillo, Stephanie; Royalty, Janet; Rice, Ketra; Gressard, Lindsay; Miller, Jacqueline W
2016-01-01
The National Breast and Cervical Cancer Early Detection Program (NBCCEDP) provides cancer screening to low-income, un-, and underinsured women through more than 11 000 primary care clinics. The program is well-positioned to work with health systems to implement evidence-based interventions (EBIs) to increase screening among all women. To collect baseline data on EBI use, evaluation of EBIs, and related training needs among NBCCEDP grantees. The Centers for Disease Control and Prevention conducted a Web-based survey in late 2013 among NBCCEDP grantees for the period July 2012 to June 2013. This was the first systematic assessment of EBIs among NBCCEDP grantees. The Centers for Disease Control and Prevention's NBCCEDP. Primarily program directors/coordinators for all 67 NBCCEDP grantees. Data captured were used to assess implementation of 5 EBIs, their evaluation, and related training needs. Frequencies and proportions were determined. Cluster analysis identified grantees with similar patterns of EBI use for NBCCEDP clients and providers. On average, 4.1 of 5 EBIs were implemented per grantee for NBCCEDP clients and providers. Four clusters were identified including "high overall EBI users," "high provider EBI users," "high EBI users with no provider assessment and feedback," and "high client EBI users." Only 1.8 EBIs were implemented, on average, with non-NBCCEDP clients and providers. Fewer than half (n = 32, 47.8%) of grantees conducted process or outcome evaluation of 1 or more EBIs. Overall, 47.6% of grantees reported high or medium training needs for client-oriented EBIs and 54.3% for provider-oriented EBIs. The NBCCEDP grantees are implementing EBIs extensively with clients and providers. Increased EBI use among non-NBCCEDP clients/providers is needed to extend the NBCCEDP's reach and impact. Grantee training and technical assistance is necessary across EBIs. In addition, grantees' use of process and outcome evaluation of EBI implementation must be increased to inform effective program implementation.
NASA Astrophysics Data System (ADS)
Mulmule, Manoj D.; Shimmy, Shankar M.; Bambole, Vaishali; Jamdar, Sahayog N.; Rawat, K. P.; Sarma, K. S. S.
2017-02-01
Idli, a steam-cooked breakfast food item consumed in India, is famous as a staple food for its spongy texture and unique fermented taste. Idli preparation is a time consuming process; although instant Idli pre-mixes as powder or batter are available in the market, they do not have the distinctive taste and aroma similar to the Idli prepared at home. Hence ready-to-eat (RTE) form of this food is in demand. Therefore, an attempt was made to prepare RTE Idli bearing similar taste as home-cooked Idli with an extended shelf-life of up to two months at an ambient temperature using Electron Beam Irradiation (EBI) at dosages 2.5 kGy, 5 kGy and 7.5 kGy and combination processing comprised of EBI dosage at 2.5 kGy and thermal treatment (80 °C for 20 min). The treated Idli's were microbiologically and sensorially evaluated at storage periods of zero day, 14 days, 30 days and 60 days. Idli's irradiated at 7.5 kGy and subjected to combination processing at 2.5 kGy and thermal treatment were shelf-stable for 60 days. 2.5 kGy and 5 kGy radiation dosages alone were not sufficient to preserve Idli samples for more than 14 days. Undesirable change in sensory properties of Idli was observed at an EBI dosage of 7.5 kGy. Sensory properties of combination processed Idli's were found to undergo minor change over the storage period. The present work suggests that lowest radiation dosage in combination with thermal treatment could be useful to achieve the extended shelf-life without considerably impairing the organoleptic quality of Ready-to-Eat Idli.
Disruptive Innovations for Designing and Diffusing Evidence-based Interventions
Rotheram-Borus, Mary Jane; Swendeman, Dallas; Chorpita, Bruce F.
2013-01-01
The numbers of evidence-based interventions (EBIs) have been growing exponentially, both therapeutic and prevention programs. Yet, EBIs have not been broadly adopted in the United States. In order for our EBI science to significantly reduce disease burden, we need to critically re-examine our scientific conventions and norms. Innovation may be spurred by re-examining the biomedical model for validating EBIs and the compartmentalization of EBIs as disease-specific, institutionally-based, counseling programs. The model of Disruptive Innovations suggests that we re-engineer EBIs based on their most robust features in order to reach more people in less time and at lower cost. Four new research agendas will be required to support disruptive innovations in EBI science: synthesize common elements across EBIs; experiment with new delivery formats (e.g., consumer controlled, self-directed, brief, paraprofessional, coaching, and technology and media strategies); adopt market strategies to promote and diffuse EBI science, knowledge, and products; and adopt continuous quality improvement as a research paradigm for systematically improving EBIs, based on ongoing data and feedback. EBI science can have more impact if it can better leverage what we know from existing EBIs in order to inspire, engage, inform, and support families and children to adopt and sustain healthy daily routines and lifestyles. PMID:22545596
The European Bioinformatics Institute in 2017: data coordination and integration
Cochrane, Guy; Apweiler, Rolf; Birney, Ewan
2018-01-01
Abstract The European Bioinformatics Institute (EMBL-EBI) supports life-science research throughout the world by providing open data, open-source software and analytical tools, and technical infrastructure (https://www.ebi.ac.uk). We accommodate an increasingly diverse range of data types and integrate them, so that biologists in all disciplines can explore life in ever-increasing detail. We maintain over 40 data resources, many of which are run collaboratively with partners in 16 countries (https://www.ebi.ac.uk/services). Submissions continue to increase exponentially: our data storage has doubled in less than two years to 120 petabytes. Recent advances in cellular imaging and single-cell sequencing techniques are generating a vast amount of high-dimensional data, bringing to light new cell types and new perspectives on anatomy. Accordingly, one of our main focus areas is integrating high-quality information from bioimaging, biobanking and other types of molecular data. This is reflected in our deep involvement in Open Targets, stewarding of plant phenotyping standards (MIAPPE) and partnership in the Human Cell Atlas data coordination platform, as well as the 2017 launch of the Omics Discovery Index. This update gives a birds-eye view of EMBL-EBI’s approach to data integration and service development as genomics begins to enter the clinic. PMID:29186510
Design Considerations for High Energy Electron -- Positron Storage Rings
DOE R&D Accomplishments Database
Richter, B.
1966-11-01
High energy electron-positron storage rings give a way of making a new attack on the most important problems of elementary particle physics. All of us who have worked in the storage ring field designing, building, or using storage rings know this. The importance of that part of storage ring work concerning tests of quantum electrodynamics and mu meson physics is also generally appreciated by the larger physics community. However, I do not think that most of the physicists working tin the elementary particle physics field realize the importance of the contribution that storage ring experiments can make to our understanding of the strongly interacting particles. I would therefore like to spend the next few minutes discussing the sort of things that one can do with storage rings in the strongly interacting particle field.
Leeman, Jennifer; Calancie, Larissa; Kegler, Michelle C.; Escoffery, Cam T.; Herrmann, Alison K.; Thatcher, Esther; Hartman, Marieke A.; Fernandez, Maria
2017-01-01
Public health and other community-based practitioners have access to a growing number of evidence-based interventions (EBIs), and yet EBIs continue to be underused. One reason for this underuse is that practitioners often lack the capacity (knowledge, skills, and motivation) to select, adapt, and implement EBIs. Training, technical assistance, and other capacity-building strategies can be effective at increasing EBI adoption and implementation. However, little is known about how to design capacity-building strategies or tailor them to differences in capacity required across varying EBIs and practice contexts. To address this need, we conducted a scoping study of frameworks and theories detailing variations in EBIs or practice contexts and how to tailor capacity-building to address those variations. Using an iterative process, we consolidated constructs and propositions across 24 frameworks and developed a beginning theory to describe salient variations in EBIs (complexity and uncertainty) and practice contexts (decision-making structure, general capacity to innovate, resource and values fit with EBI, and unity vs. polarization of stakeholder support). The theory also includes propositions for tailoring capacity-building strategies to address salient variations. To have wide-reaching and lasting impact, the dissemination of EBIs needs to be coupled with strategies that build practitioners’ capacity to adopt and implement a variety of EBIs across diverse practice contexts. PMID:26500080
Leeman, Jennifer; Calancie, Larissa; Kegler, Michelle C; Escoffery, Cam T; Herrmann, Alison K; Thatcher, Esther; Hartman, Marieke A; Fernandez, Maria E
2017-02-01
Public health and other community-based practitioners have access to a growing number of evidence-based interventions (EBIs), and yet EBIs continue to be underused. One reason for this underuse is that practitioners often lack the capacity (knowledge, skills, and motivation) to select, adapt, and implement EBIs. Training, technical assistance, and other capacity-building strategies can be effective at increasing EBI adoption and implementation. However, little is known about how to design capacity-building strategies or tailor them to differences in capacity required across varying EBIs and practice contexts. To address this need, we conducted a scoping study of frameworks and theories detailing variations in EBIs or practice contexts and how to tailor capacity-building to address those variations. Using an iterative process, we consolidated constructs and propositions across 24 frameworks and developed a beginning theory to describe salient variations in EBIs (complexity and uncertainty) and practice contexts (decision-making structure, general capacity to innovate, resource and values fit with EBI, and unity vs. polarization of stakeholder support). The theory also includes propositions for tailoring capacity-building strategies to address salient variations. To have wide-reaching and lasting impact, the dissemination of EBIs needs to be coupled with strategies that build practitioners' capacity to adopt and implement a variety of EBIs across diverse practice contexts.
The EMBL-EBI bioinformatics web and programmatic tools framework.
Li, Weizhong; Cowley, Andrew; Uludag, Mahmut; Gur, Tamer; McWilliam, Hamish; Squizzato, Silvano; Park, Young Mi; Buso, Nicola; Lopez, Rodrigo
2015-07-01
Since 2009 the EMBL-EBI Job Dispatcher framework has provided free access to a range of mainstream sequence analysis applications. These include sequence similarity search services (https://www.ebi.ac.uk/Tools/sss/) such as BLAST, FASTA and PSI-Search, multiple sequence alignment tools (https://www.ebi.ac.uk/Tools/msa/) such as Clustal Omega, MAFFT and T-Coffee, and other sequence analysis tools (https://www.ebi.ac.uk/Tools/pfa/) such as InterProScan. Through these services users can search mainstream sequence databases such as ENA, UniProt and Ensembl Genomes, utilising a uniform web interface or systematically through Web Services interfaces (https://www.ebi.ac.uk/Tools/webservices/) using common programming languages, and obtain enriched results with novel visualisations. Integration with EBI Search (https://www.ebi.ac.uk/ebisearch/) and the dbfetch retrieval service (https://www.ebi.ac.uk/Tools/dbfetch/) further expands the usefulness of the framework. New tools and updates such as NCBI BLAST+, InterProScan 5 and PfamScan, new categories such as RNA analysis tools (https://www.ebi.ac.uk/Tools/rna/), new databases such as ENA non-coding, WormBase ParaSite, Pfam and Rfam, and new workflow methods, together with the retirement of depreciated services, ensure that the framework remains relevant to today's biological community. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.
Oxysterol-EBI2 signaling in immune regulation and viral infection.
Daugvilaite, Viktorija; Arfelt, Kristine Niss; Benned-Jensen, Tau; Sailer, Andreas W; Rosenkilde, Mette M
2014-07-01
The seven transmembrane G protein-coupled receptor Epstein-Barr virus (EBV) induced gene 2 (EBI2; also known as GPR183) was identified in 1993 on the basis of its substantial upregulation in EBV-infected cells. It is primarily expressed in lymphoid cells; most abundantly in B cells. EBI2 is central for the positioning of B cells within the lymphoid organs, a process that is regulated in part by a chemotactic gradient formed by the endogenous lipid agonists, and in part by a fine-tuned regulation of EBI2 cell surface expression. The most potent endogenous EBI2 agonist is 7α, 25-dihydroxyxcholesterol (7α,25-OHC), yet many structurally related oxysterols can bind to an EBI2 pocket that is defined by the upper parts of the transmembrane helices and extracellular receptor regions. EBI2 signals via Gαi, as well as via G protein-independent pathways like β-arrestin recruitment. The concerted action of these pathways leads to cell migration. By genetically interfering with its up- and downregulation, EBI2 was also recently shown to induce cell proliferation, an action that could be inhibited by small molecule antagonists. Here, we focus on the oxysterol-EBI2 axis in immune control, including its role in the EBV life cycle. We also summarize the structural and functional properties of EBI2 interaction with oxysterol agonists and small molecule antagonists and discuss EBI2 as therapeutic target for diseases of the immune system. © 2014 The Authors. European Journal of Immunology published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Disruptive innovations for designing and diffusing evidence-based interventions.
Rotheram-Borus, Mary Jane; Swendeman, Dallas; Chorpita, Bruce F
2012-09-01
Evidence-based therapeutic and preventive intervention programs (EBIs) have been growing exponentially. Yet EBIs have not been broadly adopted in the United States. In order for our EBI science to significantly reduce disease burden, we need to critically reexamine our scientific conventions and norms. Innovation may be spurred by reexamining the traditional biomedical model for validating, implementing, and diffusing EBI products and science. The model of disruptive innovations suggests that we reengineer EBIs on the basis of their most robust features in order to serve more people in less time and at lower cost. A disruptive innovation provides a simpler and less expensive alternative that meets the essential needs for the majority of consumers and is more accessible, scalable, replicable, and sustainable. Examples of disruptive innovations from other fields include minute clinics embedded in retail chain drug stores, $2 generic eyeglasses, automated teller machines, and telemedicine. Four new research approaches will be required to support disruptive innovations in EBI science: synthesize common elements across EBIs; experiment with new delivery formats (e.g., consumer controlled, self-directed, brief, paraprofessional, coaching, and technology and media strategies); adopt market strategies to promote and diffuse EBI science, knowledge, and products; and adopt continuous quality improvement as a research paradigm for systematically improving EBIs, based on ongoing monitoring data and feedback. EBI science can have more impact if it can better leverage what we know from existing EBIs in order to inspire, engage, inform, and support families and children to adopt and sustain healthy daily routines and lifestyles. (PsycINFO Database Record (c) 2012 APA, all rights reserved).
Off-line commissioning of EBIS and plans for its integration into ATLAS and CARIBU.
Ostroumov, P N; Barcikowski, A; Dickerson, C A; Mustapha, B; Perry, A; Sharamentov, S I; Vondrasek, R C; Zinkann, G
2016-02-01
An Electron Beam Ion Source Charge Breeder (EBIS-CB) has been developed at Argonne to breed radioactive beams from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) facility at Argonne Tandem Linac Accelerator System (ATLAS). The EBIS-CB will replace the existing ECR charge breeder to increase the intensity and significantly improve the purity of reaccelerated radioactive ion beams. The CARIBU EBIS-CB has been successfully commissioned offline with an external singly charged cesium ion source. The performance of the EBIS fully meets the specifications to breed rare isotope beams delivered from CARIBU. The EBIS is being relocated and integrated into ATLAS and CARIBU. A long electrostatic beam transport system including two 180° bends in the vertical plane has been designed. The commissioning of the EBIS and the beam transport system in their permanent location will start at the end of this year.
Off-line commissioning of EBIS and plans for its integration into ATLAS and CARIBU
NASA Astrophysics Data System (ADS)
Ostroumov, P. N.; Barcikowski, A.; Dickerson, C. A.; Mustapha, B.; Perry, A.; Sharamentov, S. I.; Vondrasek, R. C.; Zinkann, G.
2016-02-01
An Electron Beam Ion Source Charge Breeder (EBIS-CB) has been developed at Argonne to breed radioactive beams from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) facility at Argonne Tandem Linac Accelerator System (ATLAS). The EBIS-CB will replace the existing ECR charge breeder to increase the intensity and significantly improve the purity of reaccelerated radioactive ion beams. The CARIBU EBIS-CB has been successfully commissioned offline with an external singly charged cesium ion source. The performance of the EBIS fully meets the specifications to breed rare isotope beams delivered from CARIBU. The EBIS is being relocated and integrated into ATLAS and CARIBU. A long electrostatic beam transport system including two 180° bends in the vertical plane has been designed. The commissioning of the EBIS and the beam transport system in their permanent location will start at the end of this year.
Measurements of charge state breeding efficiency at BNL test EBIS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kondrashev, S.; Alessi, J.; Beebe, E.N.
Charge breeding of singly charged ions is required to efficiently accelerate rare isotope ion beams for nuclear and astrophysics experiments, and to enhance the accuracy of low-energy Penning trap-assisted spectroscopy. An efficient charge breeder for the Californium Rare Isotope Breeder Upgrade (CARIBU) to the ANL Tandem Linear Accelerator System (ATLAS) facility is being developed using the BNL Test Electron Beam Ion Source (Test EBIS) as a prototype. Parameters of the CARIBU EBIS charge breeder are similar to those of the BNL Test EBIS except the electron beam current will be adjustable in the range from 1 to 2 {angstrom}. Themore » electron beam current density in the CARIBU EBIS trap will be significantly higher than in existing operational charge state breeders based on the EBIS concept. The charge state breeding efficiency is expected to be about 25% for the isotope ions extracted from the CARIBU. For the success of our EBIS project, it is essential to demonstrate high breeding efficiency at the BNL Test EBIS tuned to the regime close to the parameters of the CARIBU EBIS at ANL. The breeding efficiency optimization and measurements have been successfully carried out using a Cs{sup +} surface ionization ion source for externally pulsed injection into the BNL Test EBIS. A Cs{sup +} ion beam with a total number of ions of 5 x 10{sup 8} and optimized pulse length of 70 {mu}s has been injected into the Test EBIS and charge-bred for 5.3 ms for two different electron beam currents 1 and 1.5 {angstrom}. In these experiments we have achieved 70% injection/extraction efficiency and breeding efficiency into the most abundant charge state 17%.« less
Squizzato, Silvano; Park, Young Mi; Buso, Nicola; Gur, Tamer; Cowley, Andrew; Li, Weizhong; Uludag, Mahmut; Pundir, Sangya; Cham, Jennifer A; McWilliam, Hamish; Lopez, Rodrigo
2015-07-01
The European Bioinformatics Institute (EMBL-EBI-https://www.ebi.ac.uk) provides free and unrestricted access to data across all major areas of biology and biomedicine. Searching and extracting knowledge across these domains requires a fast and scalable solution that addresses the requirements of domain experts as well as casual users. We present the EBI Search engine, referred to here as 'EBI Search', an easy-to-use fast text search and indexing system with powerful data navigation and retrieval capabilities. API integration provides access to analytical tools, allowing users to further investigate the results of their search. The interconnectivity that exists between data resources at EMBL-EBI provides easy, quick and precise navigation and a better understanding of the relationship between different data types including sequences, genes, gene products, proteins, protein domains, protein families, enzymes and macromolecular structures, together with relevant life science literature. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.
The EBI SRS server-new features.
Zdobnov, Evgeny M; Lopez, Rodrigo; Apweiler, Rolf; Etzold, Thure
2002-08-01
Here we report on recent developments at the EBI SRS server (http://srs.ebi.ac.uk). SRS has become an integration system for both data retrieval and sequence analysis applications. The EBI SRS server is a primary gateway to major databases in the field of molecular biology produced and supported at EBI as well as European public access point to the MEDLINE database provided by US National Library of Medicine (NLM). It is a reference server for latest developments in data and application integration. The new additions include: concept of virtual databases, integration of XML databases like the Integrated Resource of Protein Domains and Functional Sites (InterPro), Gene Ontology (GO), MEDLINE, Metabolic pathways, etc., user friendly data representation in 'Nice views', SRSQuickSearch bookmarklets. SRS6 is a licensed product of LION Bioscience AG freely available for academics. The EBI SRS server (http://srs.ebi.ac.uk) is a free central resource for molecular biology data as well as a reference server for the latest developments in data integration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pikin, A.
2017-11-21
Electron beam ion sources technology made significant progress since 1968 when this method of producing highly charged ions in a potential trap within electron beam was proposed by E. Donets. Better understanding of physical processes in EBIS, technological advances and better simulation tools determined significant progress in key EBIS parameters: electron beam current and current density, ion trap capacity, attainable charge states. Greatly increased the scope of EBIS and EBIT applications. An attempt is made to compile some of EBIS engineering problems and solutions and to demonstrate a present stage of understanding the processes and approaches to build a bettermore » EBIS.« less
Zhang, Song-An; Niyazi, Hu-Er-Xi-Dan; Hong, Wen; Tuluwengjiang, Gu-Li-Xian; Zhang, Lei; Zhang, Yang; Su, Wei-Peng; Bao, Yong-Xing
2017-03-01
This study aimed to investigate the effect of EBI3 on radiation-induced immunosuppression of cervical cancer HeLa cells by regulating Treg cells through PD-1/PD-L1 signaling pathway. A total of 43 adult female Wistar rats were selected and injected with HeLa cells in the caudal vein to construct a rat model of cervical cancer. All model rats were randomly divided into the radiotherapy group ( n = 31) and the control group ( n = 12). The immunophenotype of Treg cells was detected by the flow cytometry. The protein expressions of EBI3, PD-1, and PD-L1 in cervical cancer tissues were tested by the streptavidin-peroxidase method. HeLa cells in the logarithmic growth phase were divided into four groups: the blank, the negative control group, the EBI3 mimics group, and the EBI3 inhibitors group. Western blotting was used to detect PD-1 and PD-L1 protein expressions. MTT assay was performed to measure the proliferation of Treg cells. Flow cytometry was used to detect cell cycle and apoptosis, and CD4 + /CD8 + T cell ratio in each group. Compared with before and 1 week after radiotherapy, the percentages of CD4 + T cells and CD8 + T cells were significantly decreased in the radiotherapy group at 1 month after radiotherapy. Furthermore, down-regulation of EBI3 and up-regulation of PD-1 and PD-L1 were observed in cervical cancer tissues at 1 month after radiotherapy. In comparison to the blank and negative control groups, increased expression of EBI3 and decreased expressions of PD-1 and PD-L1 were found in the EBI3 mimics group. However, the EBI3 inhibitors group had a lower expression of EBI3 and higher expressions of PD-1 and PD-L1 than those in the blank and negative control groups. The EBI3 mimics group showed an increase in the optical density value (0.43 ± 0.05), while a decrease in the optical density value (0.31 ± 0.02) was found in the EBI3 inhibitors group. Moreover, compared with the blank and negative control groups, the apoptosis rates of Treg/CD4 + T/CD8 + T cells were decreased in the EBI3 mimics group, but the EBI3 inhibitors group exhibited an increase in apoptosis rate. In conclusion, over-expression of EBI3 could reduce the apoptosis of Treg/CD4 + T/CD8 + T cells and prevent radiation-induced immunosuppression of cervical cancer HeLa cells by inhibiting the activation of PD-1/PD-L1 signaling pathway.
Aarons, Gregory A; Green, Amy E; Willging, Cathleen E; Ehrhart, Mark G; Roesch, Scott C; Hecht, Debra B; Chaffin, Mark J
2014-12-10
This study examines sustainment of an EBI implemented in 11 United States service systems across two states, and delivered in 87 counties. The aims are to 1) determine the impact of state and county policies and contracting on EBI provision and sustainment; 2) investigate the role of public, private, and academic relationships and collaboration in long-term EBI sustainment; 3) assess organizational and provider factors that affect EBI reach/penetration, fidelity, and organizational sustainment climate; and 4) integrate findings through a collaborative process involving the investigative team, consultants, and system and community-based organization (CBO) stakeholders in order to further develop and refine a conceptual model of sustainment to guide future research and provide a resource for service systems to prepare for sustainment as the ultimate goal of the implementation process. A mixed-method prospective and retrospective design will be used. Semi-structured individual and group interviews will be used to collect information regarding influences on EBI sustainment including policies, attitudes, and practices; organizational factors and external policies affecting model implementation; involvement of or collaboration with other stakeholders; and outer- and inner-contextual supports that facilitate ongoing EBI sustainment. Document review (e.g., legislation, executive orders, regulations, monitoring data, annual reports, agendas and meeting minutes) will be used to examine the roles of state, county, and local policies in EBI sustainment. Quantitative measures will be collected via administrative data and web surveys to assess EBI reach/penetration, staff turnover, EBI model fidelity, organizational culture and climate, work attitudes, implementation leadership, sustainment climate, attitudes toward EBIs, program sustainment, and level of institutionalization. Hierarchical linear modeling will be used for quantitative analyses. Qualitative analyses will be tailored to each of the qualitative methods (e.g., document review, interviews). Qualitative and quantitative approaches will be integrated through an inclusive process that values stakeholder perspectives. The study of sustainment is critical to capitalizing on and benefiting from the time and fiscal investments in EBI implementation. Sustainment is also critical to realizing broad public health impact of EBI implementation. The present study takes a comprehensive mixed-method approach to understanding sustainment and refining a conceptual model of sustainment.
McKay, Virginia R; Margaret Dolcini, M; Hoffer, Lee D
2017-12-01
Evidence-based intervention (EBI) de-adoption and its influence on public health organizations are largely unexplored within public health implementation research. However, a recent shift in support for HIV prevention EBIs by the Centers for Disease Control and Prevention provides an opportunity to explore EBI de-adoption. The current mixed-method study examines EBI de-adoption and the subsequent impact on a community-based organization (CBO) dedicated to HIV prevention. We conducted a case study with a CBO implementing RESPECT, an HIV prevention EBI, over 5 years (2010-2014), but then de-adopted the intervention. We collected archival data documenting RESPECT implementation and conducted two semi-structured interviews with RESPECT staff (N = 5). Using Fixsen and colleagues' implementation framework, we developed a narrative of RESPECT implementation, delivery, and de-adoption and a thematic analysis to understand additional consequences of RESPECT de-adoption. Discontinuation of RESPECT activities unfolded in a process over time, requiring effort by RESPECT staff. RESPECT de-adoption had wide-reaching influences on individual staff, interactions between the staff and the community, the agency overall, and for implementation of future EBIs. We propose a revision of the implementation framework, incorporating EBI de-adoption as a phase of the implementation cycle. Furthermore, EBI de-adoption may have important, unintended consequences and can inform future HIV prevention strategies and guide research focusing on EBI de-adoption.
Low dose elective brain irradiation in small cell carcinoma of the lung
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beiler, D.D.; Kane, R.C.; Bernath, A.M.
Elective brain irradiation (EBI) in a dosage of 3000 rad (midplane) in 2 weeks (nominal standard dose (NSD) = 1314 ret) has proven highly effective in preventing initial brain relapse in small cell lung carcinoma. However, the optimal radiation dose for EBI is unknown. 55 patients (31 with regional disease, 24 with extensive disease) without brain metastases were treated with a 4 drug chemotherapy program, (lomustine (CCNU), methotrexate, cyclophosphamide, vincristine) plus radiotherapy (R.T.), 3000 rad in 2 weeks to the primary chest lesion and were randomized to EBI or a control group. The EBI consisted of 2400 rad whole brain,more » midplane, in 8 fractions, 10 days (NSD = 1130 ret) given at the same time as the R.T. to the primary (3 weeks post-initial chemotherapy). Though all 54 evaluable patients received CCNU 50 mg/M/sup 2/q. 6 weeks, there were 5 initial brain relapses among 31 control patients (16%) vs none in the 23 EBI patients. The time at risk for recurrence was similar in the two groups, i.e. 31 weeks median in the EBI and 32 weeks in the no-EBI patients. Brain relapses occurred in 2/17 with limited disease and 3/14 with extensive disease. It appears that 2400 rad in 8 fractions is as effective for EBI as larger doses. Toxicity was limited to alopecia. Survival was not significantly affected by EBI, though there is a suggestion of improvement in the regional group.« less
Electron-beam-ion-source (EBIS) modeling progress at FAR-TECH, Inc
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, J. S., E-mail: kim@far-tech.com; Zhao, L., E-mail: kim@far-tech.com; Spencer, J. A., E-mail: kim@far-tech.com
FAR-TECH, Inc. has been developing a numerical modeling tool for Electron-Beam-Ion-Sources (EBISs). The tool consists of two codes. One is the Particle-Beam-Gun-Simulation (PBGUNS) code to simulate a steady state electron beam and the other is the EBIS-Particle-In-Cell (EBIS-PIC) code to simulate ion charge breeding with the electron beam. PBGUNS, a 2D (r,z) electron gun and ion source simulation code, has been extended for efficient modeling of EBISs and the work was presented previously. EBIS-PIC is a space charge self-consistent PIC code and is written to simulate charge breeding in an axisymmetric 2D (r,z) device allowing for full three-dimensional ion dynamics.more » This 2D code has been successfully benchmarked with Test-EBIS measurements at Brookhaven National Laboratory. For long timescale (< tens of ms) ion charge breeding, the 2D EBIS-PIC simulations take a long computational time making the simulation less practical. Most of the EBIS charge breeding, however, may be modeled in 1D (r) as the axial dependence of the ion dynamics may be ignored in the trap. Where 1D approximations are valid, simulations of charge breeding in an EBIS over long time scales become possible, using EBIS-PIC together with PBGUNS. Initial 1D results are presented. The significance of the magnetic field to ion dynamics, ion cooling effects due to collisions with neutral gas, and the role of Coulomb collisions are presented.« less
Design and numerical characterization of a crossover EBIS
NASA Astrophysics Data System (ADS)
Geyer, Sabrina; Langbein, A.; Meusel, Oliver; Kester, Oliver
2015-01-01
For the investigation of highly charged ions, a crossover EBIS (XEBIS) was developed at the University of Frankfurt. In contrast to conventional EBIS/T devices the compression of the electron beam is achieved by electrostatic focusing to a crossover point in the interaction region. This concept allows a compact and simple design. Simulations performed with EGUN show a perveance of 2.1×10-7 A/V3/2 for the realized gun system. In the interaction region the electron beam has a density of around 10 A/cm2 and a minimum radius of 0.15 mm. The XEBIS has a total length of 112 mm with a trap length of 26 mm. It is designed for electron beam energies of up to 6 keV/q. The storage capacity of the trap region is in the order of 1×108 charges. Charge state breeding studies with CBSIM indicate for the noble gases as maximal achievable charge state Ar16+, Kr30+ and Xe35+. Thus ion beam currents of around 2.04 nA assuming 50 Hz repetition rate can be expected. The emittance of the extracted beam is approximated to 8 mm mrad. After completion of the construction phase, the XEBIS will be installed for first performance investigations at a dedicated test bench, equipped with a fast Faraday Cup (FC), a retarding field spectrometer, a luminescence screen and optical diagnostics. Subsequently the XEBIS will serve as source for highly charged ions at different experimental setups.
Highfield, Linda; Hartman, Marieke A; Mullen, Patricia Dolan; Rodriguez, Serena A; Fernandez, Maria E; Bartholomew, L Kay
2015-01-01
This paper describes and demonstrates the use of the systematic planning process, Intervention Mapping, to adapt an evidence-based public health intervention (EBI). We used a simplified version of Intervention Mapping (IM Adapt) to increase an intervention's fit with a new setting and population. IM Adapt guides researchers and practitioners in selecting an EBI, making decisions about whether and what to adapt, and executing the adaptation while guarding the EBI's essential elements (those responsible for effectiveness). We present a case study of a project in which we used IM Adapt to find, adapt, implement, and evaluate an EBI to improve mammography adherence for African American women in a new practice setting in Houston, Texas. IM Adapt includes the following (1) assess needs and organizational capacity; (2) find EBIs; (3) plan adaptations based on fit assessments; (4) make adaptations; (5) plan for implementation; and (6) plan for evaluation of the adapted EBI. The case study shows an example of how public health researchers and practitioners can use the tool to make it easier to find and use EBIs, thus encouraging greater uptake. IM Adapt adds to existing dissemination and adaptation models by providing detailed guidance on how to decide on effective adaptation, while maintaining the essential elements of the EBI.
Highfield, Linda; Hartman, Marieke A.; Mullen, Patricia Dolan; Fernandez, Maria E.; Bartholomew, L. Kay
2015-01-01
This paper describes and demonstrates the use of the systematic planning process, Intervention Mapping, to adapt an evidence-based public health intervention (EBI). We used a simplified version of Intervention Mapping (IM Adapt) to increase an intervention's fit with a new setting and population. IM Adapt guides researchers and practitioners in selecting an EBI, making decisions about whether and what to adapt, and executing the adaptation while guarding the EBI's essential elements (those responsible for effectiveness). We present a case study of a project in which we used IM Adapt to find, adapt, implement, and evaluate an EBI to improve mammography adherence for African American women in a new practice setting in Houston, Texas. IM Adapt includes the following (1) assess needs and organizational capacity; (2) find EBIs; (3) plan adaptations based on fit assessments; (4) make adaptations; (5) plan for implementation; and (6) plan for evaluation of the adapted EBI. The case study shows an example of how public health researchers and practitioners can use the tool to make it easier to find and use EBIs, thus encouraging greater uptake. IM Adapt adds to existing dissemination and adaptation models by providing detailed guidance on how to decide on effective adaptation, while maintaining the essential elements of the EBI. PMID:26587531
Longitudinal space charge compensation at PSR
NASA Astrophysics Data System (ADS)
Neri, Filippo
1998-11-01
The longitudinal space-charge force in neutron spallation source compressor ring or other high intensity proton storage rings can be compensated by introducing an insert in the ring. The effect of the inductor is to cancel all or part of the space charge potential, because it is capacitive. The Proton Storage Ring at Los Alamos National Laboratory is a compressor ring used to produce short pulses of spallation neutrons. Inductive inserts design for space charge compensation at the Los Alamos Proton Storage Ring is described.
A wireless multi-channel bioimpedance measurement system for personalized healthcare and lifestyle.
Ramos, Javier; Ausín, José Luis; Lorido, Antonio Manuel; Redondo, Francisco; Duque-Carrillo, Juan Francisco
2013-01-01
Miniaturized, noninvasive, wearable sensors constitute a fundamental prerequisite for pervasive, predictive, and preventive healthcare systems. In this sense, this paper presents the design, realization, and evaluation of a wireless multi-channel measurement system based on a cost-effective high-performance integrated circuit for electrical bioimpedance (EBI) measurements in the frequency range from 1 kHz to 1 MHz. The resulting on-chip spectrometer provides high measuring EBI capabilities and together with a low-cost, commercially available radio frequency transceiver device. It provides reliable wireless communication, constitutes the basic node to build EBI wireless sensor networks (EBI-WSNs). The proposed EBI-WSN behaves as a high-performance wireless multi-channel EBI spectrometer, where the number of channels is completely scalable and independently configurable to satisfy specific measurement requirements of each individual. A prototype of the EBI node leads to a very small printed circuit board of approximately 8 cm2 including chip-antenna, which can operate several years on one 3-V coin cell battery and make it suitable for long-term preventive healthcare monitoring.
Total water storage dynamics derived from tree-ring records and terrestrial gravity observations
NASA Astrophysics Data System (ADS)
Creutzfeldt, Benjamin; Heinrich, Ingo; Merz, Bruno
2015-10-01
For both societal and ecological reasons, it is important to understand past and future subsurface water dynamics but estimating subsurface water storage is notoriously difficult. In this pilot study, we suggest the reconstruction of subsurface water dynamics by a multi-disciplinary approach combining hydrology, dendrochronology and geodesy. In a first step, nine complete years of high-precision gravimeter observations are used to estimate water storage changes in the subsurface at the Geodetic Observatory Wettzell in the Bavarian Forest, Germany. The record is extended to 63 years by calibrating a hydrological model against the 9 years of gravimeter observations. The relationship between tree-ring growth and water storage changes is evaluated as well as that between tree-ring growth and supplementary hydro-meteorological data. Results suggest that tree-ring growth is influenced primarily by subsurface water storage. Other variables related to the overall moisture status (e.g., Standardized Precipitation Index, Palmer Drought Severity Index, streamflow) are also strongly correlated with tree-ring width. While these indices are all indicators of water stored in the landscape, water storage changes of the subsurface estimated by depth-integral measurements give us the unique opportunity to directly reconstruct subsurface water storage dynamics from records of tree-ring width. Such long reconstructions will improve our knowledge of past water storage variations and our ability to predict future developments. Finally, knowing the relationship between subsurface storage dynamics and tree-ring growth improves the understanding of the different signal components contained in tree-ring chronologies.
The EBI search engine: EBI search as a service—making biological data accessible for all
Park, Young M.; Squizzato, Silvano; Buso, Nicola; Gur, Tamer
2017-01-01
Abstract We present an update of the EBI Search engine, an easy-to-use fast text search and indexing system with powerful data navigation and retrieval capabilities. The interconnectivity that exists between data resources at EMBL–EBI provides easy, quick and precise navigation and a better understanding of the relationship between different data types that include nucleotide and protein sequences, genes, gene products, proteins, protein domains, protein families, enzymes and macromolecular structures, as well as the life science literature. EBI Search provides a powerful RESTful API that enables its integration into third-party portals, thus providing ‘Search as a Service’ capabilities, which are the main topic of this article. PMID:28472374
Colorectal Cancer Control Program Grantees’ Use of Evidence-Based Interventions
Hannon, Peggy A.; Maxwell, Annette E.; Escoffery, Cam; Vu, Thuy; Kohn, Marlana; Leeman, Jennifer; Carvalho, Michelle L.; Pfeiffer, Debbie J.; Dwyer, Andrea; Fernandez, Maria E.; Vernon, Sally W.; Liang, Lily; DeGroff, Amy
2015-01-01
Background Colorectal cancer (CRC) screening is recommended for adults aged 50–75 years, yet screening rates are low, especially among the uninsured. The CDC initiated the Colorectal Cancer Control Program (CRCCP) in 2009 with the goal of increasing CRC screening rates to 80% by 2014. A total of 29 grantees (states and tribal organizations) receive CRCCP funding to (1) screen uninsured adults and (2) promote CRC screening at the population level. Purpose CRCCP encourages grantees to use one or more of five evidence-based interventions (EBIs) recommended by the Guide to Community Preventive Services. The purpose of the study was to evaluate grantees’ EBI use. Methods A web-based survey was conducted in 2011 measuring grantees’ use of CRC screening EBIs and identifying their implementation partners. Data were analyzed in 2012. Results Twenty-eight grantees (97%) completed the survey. Most respondents (96%) used small media. Fewer used client reminders (75%); reduction of structural barriers (50%); provider reminders (32%); or provider assessment and feedback (50%). Provider-oriented EBIs were rated as harder to implement than client-oriented EBIs. Grantees partnered with several types of organizations to implement EBIs, many with county- or state-wide reach. Conclusions Almost all grantees implement EBIs to promote CRC screening, but the EBIs that may have the greatest impact with CRC screening are implemented by fewer grantees in the first 2 years of the CRCCP. PMID:24139779
McKay, Virginia R; Hoffer, Lee D; Combs, Todd B; Margaret Dolcini, M
2018-06-05
Sustaining evidence-based interventions (EBIs) is an ongoing challenge for dissemination and implementation science in public health and social services. Characterizing the relationship among human resource capacity within an agency and subsequent population outcomes is an important step to improving our understanding of how EBIs are sustained. Although human resource capacity and population outcomes are theoretically related, examining them over time within real-world experiments is difficult. Simulation approaches, especially agent-based models, offer advantages that complement existing methods. We used an agent-based model to examine the relationships among human resources, EBI delivery, and population outcomes by simulating provision of an EBI through a hypothetical agency and its staff. We used data from existing studies examining a widely implemented HIV prevention intervention to inform simulation design, calibration, and validity. Once we developed a baseline model, we used the model as a simulated laboratory by systematically varying three human resource variables: the number of staff positions, the staff turnover rate, and timing in training. We tracked the subsequent influence on EBI delivery and the level of population risk over time to describe the overall and dynamic relationships among these variables. Higher overall levels of human resource capacity at an agency (more positions) led to more extensive EBI delivery over time and lowered population risk earlier in time. In simulations representing the typical human resource investments, substantial influences on population risk were visible after approximately 2 years and peaked around 4 years. Human resources, especially staff positions, have an important impact on EBI sustainability and ultimately population health. A minimum level of human resources based on the context (e.g., size of the initial population and characteristics of the EBI) is likely needed for an EBI to have a meaningful impact on population outcomes. Furthermore, this model demonstrates how ABMs may be leveraged to inform research design and assess the impact of EBI sustainability in practice.
Mirzaei, Ali; Kwon, Yong Jung; Wu, Ping; Kim, Sang Sub; Kim, Hyoun Woo
2018-02-28
We studied the effects of electron-beam irradiation (EBI) on the structural and gas-sensing properties of graphene oxide (GO). To understand the effects of EBI on the structure and gas-sensing behavior of irradiated GO, the treated GO was compared with nonirradiated GO. Characterization results indicated an enhancement in the number of oxygen functional groups that occurs with EBI exposure at 100 kGy and then decreases with doses in the range of 100-500 kGy. Data from Raman spectra indicated that EBI could generate defects, and NO 2 -sensing results at room temperature showed a decreased NO 2 response after exposure to EBI at 100 kGy; further increasing the dose to 500 kGy resulted in p-type semiconducting conductivity. The conversion of GO from n-type to p-type via EBI is explained not only through the generation of holes but also the variation in the amount of residual functional groups, including carboxyl (COOH) and hydroxyl groups (C-OH). The obtained results suggest that EBI can be a useful tool to convert GO into a diverse range of sensing devices.
Beam dynamics and expected performance of Sweden's new storage-ring light source: MAX IV
NASA Astrophysics Data System (ADS)
Leemann, S. C.; Andersson, Å.; Eriksson, M.; Lindgren, L.-J.; Wallén, E.; Bengtsson, J.; Streun, A.
2009-12-01
MAX IV will be Sweden’s next-generation high-performance synchrotron radiation source. The project has recently been granted funding and construction is scheduled to begin in 2010. User operation for a broad and international user community should commence in 2015. The facility is comprised of two storage rings optimized for different wavelength ranges, a linac-based short-pulse facility and a free-electron laser for the production of coherent radiation. The main radiation source of MAX IV will be a 528 m ultralow emittance storage ring operated at 3 GeV for the generation of high-brightness hard x rays. This storage ring was designed to meet the requirements of state-of-the-art insertion devices which will be installed in nineteen 5 m long dispersion-free straight sections. The storage ring is based on a novel multibend achromat design delivering an unprecedented horizontal bare lattice emittance of 0.33 nm rad and a vertical emittance below the 8 pm rad diffraction limit for 1 Å radiation. In this paper we present the beam dynamics considerations behind this storage-ring design and detail its expected unique performance.
Escoffery, Cam; Hannon, Peggy; Maxwell, Annette E; Vu, Thuy; Leeman, Jennifer; Dwyer, Andrea; Mason, Caitlin; Sowles, Shaina; Rice, Ketra; Gressard, Lindsay
2015-01-31
Practitioners often require training and technical assistance to build their capacity to select, adapt, and implement evidence-based interventions (EBIs). The CDC Colorectal Cancer Control Program (CRCCP) aims to promote CRC screening to increase population-level screening. This study identified the training and technical assistance (TA) needs and preferences for training related to the implementation of EBIs among CRCCP grantees. Twenty-nine CRCCP grantees completed an online survey about their screening activities, training and technical assistance in 2012. They rated desire for training on various evidence-based strategies to increase cancer screening, evidence-based competencies, and program management topics. They also reported preferences for training formats and facilitators and barriers to trainings. Many CRCCP grantees expressed the need for training with regards to specific EBIs, especially system-level and provider-directed EBIs to promote CRC screening. Grantees rated these EBIs as more difficult to implement than client-oriented EBIs. Grantees also reported a moderate need for training regarding finding EBIs, assessing organizational capacity, implementing selected EBIs, and conducting process and outcome evaluations. Other desired training topics reported with higher frequency were partnership development and data collection/evaluation. Grantees preferred training formats that were interactive such as on-site trainings, webinars or expert consultants. Public health organizations need greater supports for adopting evidence-based interventions, working with organizational-level change, partnership development and data management. Future capacity building efforts for the adoption of EBIs should focus on systems or provider level interventions and key processes for health promotion and should be delivered in a variety of ways to assist local organizations in cancer prevention and control.
House, L Duane; Tevendale, Heather D; Martinez-Garcia, Genevieve
2017-03-01
To describe efforts to implement evidence-based interventions (EBIs) within multicomponent, community-wide initiatives to reduce teen pregnancy. During 2011-2014, we collected information about the capacity (i.e., knowledge, confidence, training, and experience) of state and community-based organizations to support implementation of the following: EBIs, number and characteristics of youth served by EBIs, type of EBIs implemented, EBI settings, hours of training, and technical assistance provided. State and community-based organizations reported these data annually; however, training and technical assistance was reported monthly. We used aggregated data from these annual and monthly reports to describe the implementation of EBIs in the community-wide initiative project. From baseline in 2011-2014, state and community-based organizations increased their capacities to support program partners in delivering EBIs. They provided 5,015 hours of technical assistance and training on topics, including ensuring adequate capacity, process and outcome evaluation, program planning, and continuous quality improvement. Program partners increased the number of youth reached by an EBI in targeted communities by 349%, from 4,304 in the first year of implementation in 2012 to 19,344 in 2014. Most youth in 2014 received sexuality education programs (59%), whereas smaller percentages received abstinence-based, youth development, and clinic-based programs. Most youth were reached through schools (72%) and community-based organizations (16%), and smaller numbers were reached in other settings (e.g., faith-based organizations, health centers). Building and monitoring the capacity of program partners to deliver EBIs through technical assistance and training is important. In addition, partnering with schools leads to reaching more youth. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Water, gravity and trees: Relationship of tree-ring widths and total water storage dynamics
NASA Astrophysics Data System (ADS)
Creutzfeldt, B.; Heinrich, I.; Merz, B.; Blume, T.; Güntner, A.
2012-04-01
Water stored in the subsurface as groundwater or soil moisture is the main fresh water source not only for drinking water and food production but also for the natural vegetation. In a changing environment water availability becomes a critical issue in many different regions. Long-term observations of the past are needed to improve the understanding of the hydrological system and the prediction of future developments. Tree ring data have repeatedly proved to be valuable sources for reconstructing long-term climate dynamics, e.g. temperature, precipitation and different hydrological variables. In water-limited environments, tree growth is primarily influenced by total water stored in the subsurface and hence, tree-ring records usually contain information about subsurface water storage. The challenge is to retrieve the information on total water storage from tree rings, because a training dataset of water stored in the sub-surface is required for calibration against the tree-ring series. However, measuring water stored in the subsurface is notoriously difficult. We here present high-precision temporal gravimeter measurements which allow for the depth-integrated quantification of total water storage dynamics at the field scale. In this study, we evaluate the relationship of total water storage change and tree ring growth also in the context of the complex interactions of other meteorological forcing factors. A tree-ring chronology was derived from a Norway spruce stand in the Bavarian Forest, Germany. Total water storage dynamics were measured directly by the superconducting gravimeter of the Geodetic Observatory Wettzell for a 9-years period. Time series were extended to 63-years period by a hydrological model using gravity data as the only calibration constrain. Finally, water storage changes were reconstructed based on the relationship between the hydrological model and the tree-ring chronology. Measurement results indicate that tree-ring growth is primarily controlled by total water storage in the subsurface. But high uncertainties intervals of the correlation coefficient urges for the extension of the measurement period. This multi-disciplinary study, combining hydrology, dendrochronology and geodesy shows that temporal gravimeter measurements may give us the unique opportunity to retrieve the information of total water storage contained in tree-ring records to reconstruct total water storage dynamics. Knowing the relationship of water storage and tree-ring growth can also support the reconstruction of other climate records based on tree-ring series, help with hydrological model testing and can improve our knowledge of long-term variations of water storage in the past.
Jeffries, William L; Garrett, Sherese; Phields, Miriam; Olubajo, Babatunde; Lemon, Emily; Valdés-Salgado, Raydel; Collins, Charles B
2017-10-01
The Centers for Disease Control and Prevention provides trainings to support implementation of five evidence-based HIV prevention interventions (EBIs) for men who have sex with men (MSM): d-up: Defend Yourself!; Many Men, Many Voices; Mpowerment; Personalized Cognitive Counseling; and Popular Opinion Leader. We evaluated trainees' implementation of these EBIs and, using multivariable logistic regression, examined factors associated with implementation. Approximately 43% of trainees had implemented the EBIs for which they received training. Implementation was associated with working in community-based organizations (vs. health departments or other settings); acquiring training for Mpowerment or Popular Opinion Leader (vs. Personalized Cognitive Counseling); having ≥3 funding sources (vs. one); and having (vs. not having) sufficient time and necessary EBI resources. Findings suggest that implementation may vary by trainee characteristics, especially those related to employment setting, EBI training, funding, and perceived implementation barriers. Efforts that address these factors may help to improve EBI implementation among trainees.
Tran, Linda Diem
2016-01-01
A difference-in-difference approach was used to compare the effects of same-sex domestic partnership, civil union, and marriage policies on same- and different-sex partners who could have benefitted from their partners’ employer-based insurance (EBI) coverage. Same-sex partners had 78% lower odds (ME=-21%) of having EBI compared to different-sex partners, adjusting for socioeconomic and health-related factors. Same-sex partners living in states that recognized same-sex marriage or domestic partnership had 89% greater odds of having EBI compared to those in states that did not recognize same-sex unions (ME=5%). The impact of same-sex legislation on increasing take-up of dependent EBI coverage among lesbians, gay men, and bisexual individuals (LGBs) was modest, and domestic partnership legislation was equally as effective as same-sex marriage in increasing same-sex partner EBI coverage. Extending dependent EBI coverage to same-sex partners can mitigate gaps in coverage for a segment of the LGB population but will not eliminate them. PMID:26762647
Planning and Prototyping for a Storage Ring Measurement of the Proton Electric Dipole Moment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Talman, Richard
2015-07-01
Electron and proton EDM's can be measured in "frozen spin" (with the beam polarization always parallel to the orbit, for example) storage rings. For electrons the "magic" kinetic energy at which the beam can be frozen is 14.5 MeV. For protons the magic kinetic energy is 230 MeV. The currently measured upper limit for the electron EDM is much smaller than the proton EDM upper limit, which is very poorly known. Nevertheless, because the storage ring will be an order of magnitude cheaper, a sensible plan is to first build an all-electric electron storage ring as a prototype. Such anmore » electron ring was successfully built at Brookhaven, in 1954, as a prototype for their AGS ring. This leaves little uncertainty concerning the cost and performance of such a ring. (This is documentedin one of the Physical Review papers mentioned above.)« less
Predictive Toxicology: Current Status and Future Outlook (EBI ...
Slide presentation at the EBI-EMBL Industry Programme Workshop on Predictive Toxicology and the currently status of Computational Toxicology activities at the US EPA. Slide presentation at the EBI-EMBL Industry Programme Workshop on Predictive Toxicology and the currently status of Computational Toxicology activities at the US EPA.
The EBI search engine: EBI search as a service-making biological data accessible for all.
Park, Young M; Squizzato, Silvano; Buso, Nicola; Gur, Tamer; Lopez, Rodrigo
2017-07-03
We present an update of the EBI Search engine, an easy-to-use fast text search and indexing system with powerful data navigation and retrieval capabilities. The interconnectivity that exists between data resources at EMBL-EBI provides easy, quick and precise navigation and a better understanding of the relationship between different data types that include nucleotide and protein sequences, genes, gene products, proteins, protein domains, protein families, enzymes and macromolecular structures, as well as the life science literature. EBI Search provides a powerful RESTful API that enables its integration into third-party portals, thus providing 'Search as a Service' capabilities, which are the main topic of this article. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.
Storage-ring Electron Cooler for Relativistic Ion Beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Fanglei; Derbenev, Yaroslav; Douglas, David R.
Application of electron cooling at ion energies above a few GeV has been limited due to reduction of electron cooling efficiency with energy and difficulty in producing and accelerating a high-current high-quality electron beam. A high-current storage-ring electron cooler offers a solution to both of these problems by maintaining high cooling beam quality through naturally-occurring synchrotron radiation damping of the electron beam. However, the range of ion energies where storage-ring electron cooling can be used has been limited by low electron beam damping rates at low ion energies and high equilibrium electron energy spread at high ion energies. This papermore » reports a development of a storage ring based cooler consisting of two sections with significantly different energies: the cooling and damping sections. The electron energy and other parameters in the cooling section are adjusted for optimum cooling of a stored ion beam. The beam parameters in the damping section are adjusted for optimum damping of the electron beam. The necessary energy difference is provided by an energy recovering SRF structure. A prototype linear optics of such storage-ring cooler is presented.« less
Physics issues in diffraction limited storage ring design
NASA Astrophysics Data System (ADS)
Fan, Wei; Bai, ZhengHe; Gao, WeiWei; Feng, GuangYao; Li, WeiMin; Wang, Lin; He, DuoHui
2012-05-01
Diffraction limited electron storage ring is considered a promising candidate for future light sources, whose main characteristics are higher brilliance, better transverse coherence and better stability. The challenge of diffraction limited storage ring design is how to achieve the ultra low beam emittance with acceptable nonlinear performance. Effective linear and nonlinear parameter optimization methods based on Artificial Intelligence were developed for the storage ring physical design. As an example of application, partial physical design of HALS (Hefei Advanced Light Source), which is a diffraction limited VUV and soft X-ray light source, was introduced. Severe emittance growth due to the Intra Beam Scattering effect, which is the main obstacle to achieve ultra low emittance, was estimated quantitatively and possible cures were discussed. It is inspiring that better performance of diffraction limited storage ring can be achieved in principle with careful parameter optimization.
CLEARING MAGNET DESIGN FOR APS-U
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abliz, M.; Grimmer, J.; Jaski, Y.
2017-06-25
The Advanced Photon Source is in the process of developing an upgrade (APS-U) of the storage ring. The upgrade will be converting the current double bend achromat (DBA) lattice to a multi-bend achromat (MBA) lattice. In addition, the storage ring will be operated at 6 GeV and 200 mA with regular swap-out injection to keep the stored beam current constant [1]. The swap-out injection will take place with beamline shutters open. For radiation safety to ensure that no electrons can exit the storage ring, a passive method of protecting the beamline and containing the electrons inside the storage ring ismore » proposed. A clearing magnet will be located in all beamline front ends inside the storage ring tunnel. This article will discuss the features and design of the clearing magnet scheme for APS-U.« less
National Synchrotron Light Source II storage ring vacuum systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hseuh, Hsiao-Chaun, E-mail: hseuh@bnl.gov; Hetzel, Charles; Leng, Shuwei
2016-05-15
The National Synchrotron Light Source II, completed in 2014, is a 3-GeV synchrotron radiation (SR) facility at Brookhaven National Laboratory and has been in steady operation since. With a design electron current of 500 mA and subnanometer radians horizontal emittance, this 792-m circumference storage ring is providing the highest flux and brightness x-ray beam for SR users. The majority of the storage ring vacuum chambers are made of extruded aluminium. Chamber sections are interconnected using low-impedance radiofrequency shielded bellows. SR from the bending magnets is intercepted by water-cooled compact photon absorbers resided in the storage ring chambers. This paper presents themore » design of the storage ring vacuum system, the fabrication of vacuum chambers and other hardware, the installation, the commissioning, and the continuing beam conditioning of the vacuum systems.« less
The phase slip factor of the electrostatic cryogenic storage ring CSR
NASA Astrophysics Data System (ADS)
Grieser, Manfred; von Hahn, Robert; Vogel, Stephen; Wolf, Andreas
2017-07-01
To determine the momentum spread of an ion beam from the measured revolution frequency distribution, the knowledge of the phase slip factor of the storage ring is necessary. The slip factor was measured for various working points of the cryogenic storage ring CSR at MPI for Nuclear Physics, Heidelberg and was compared with simulations. The predicted functional relationship of the slip factor and the horizontal tune depends on the different islands of stability, which has been experimentally verified. This behavior of the slip factor is in clear contrast to that of magnetic storage rings.
Online optimization of storage ring nonlinear beam dynamics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Xiaobiao; Safranek, James
2015-08-01
We propose to optimize the nonlinear beam dynamics of existing and future storage rings with direct online optimization techniques. This approach may have crucial importance for the implementation of diffraction limited storage rings. In this paper considerations and algorithms for the online optimization approach are discussed. We have applied this approach to experimentally improve the dynamic aperture of the SPEAR3 storage ring with the robust conjugate direction search method and the particle swarm optimization method. The dynamic aperture was improved by more than 5 mm within a short period of time. Experimental setup and results are presented.
Zheng, Ruijuan; Liu, Haipeng; Song, Peng; Feng, Yonghong; Qin, Lianhua; Huang, Xiaochen; Chen, Jianxia; Yang, Hua; Liu, Zhonghua; Cui, Zhenglin; Hu, Zhongyi; Ge, Baoxue
2015-07-01
Tuberculosis (TB) remains a major global health problem and host genetic factors play a critical role in susceptibility and resistance to TB. The aim of this study was to identify novel candidate genes associated with TB susceptibility. We performed a population-based case-control study to genotype 13 tag SNPs spanning Epstein-Barr virus-induced gene 3 (EBI3), colony stimulating factor 2 (CSF2), IL-4, interferon beta 1 (IFNB1), chemokine (C-X-C motif) ligand 14 (CXCL14) and myeloid differentiation primary response gene 88 (Myd88) genes in 435 pulmonary TB patients and 375 health donors from China. We observed that EBI3 gene rs4740 polymorphism was associated with susceptibility to pulmonary tuberculosis (PTB) and the allele G was associated with a protective effect against PTB. Furthermore, EBI3 deficiency led to reduced bacterial burden and histopathological impairment in the lung of mice infected with Mycobacterium bovis BCG. Meanwhile, higher abundance of EBI3 was observed in the granuloma of PTB patients and in the lung tissue of BCG-infected mice. Of note, the expression of EBI3 in macrophages was remarkably induced by mycobacteria infection at both mRNA and protein level. In conclusion, EBI3 gene rs4740 polymorphism is closely associated with susceptibility to PTB and the elevation and enrichment of EBI3 in the lung which at least partially derived from macrophages may contribute to the exacerbation of mycobacterial infection. Copyright © 2015 Elsevier Ltd. All rights reserved.
Large diameter metal ring seal prevents gas leakage at 5000 psi
NASA Technical Reports Server (NTRS)
Middelkoop, J. H.
1966-01-01
Large metal ring seal prevents gas leakage in hydrogen, helium, or nitrogen storage bottles at pressures up to 5,000 psi. The grooved ring seal which contains elastomer O-rings is installed between the mating faces of the access cover and the storage bottle.
ERIC Educational Resources Information Center
Leeman, Jennifer; Calancie, Larissa; Kegler, Michelle C.; Escoffery, Cam T.; Herrmann, Alison K.; Thatcher, Esther; Hartman, Marieke A.; Fernandez, Maria E.
2017-01-01
Public health and other community-based practitioners have access to a growing number of evidence-based interventions (EBIs), and yet EBIs continue to be underused. One reason for this underuse is that practitioners often lack the capacity (knowledge, skills, and motivation) to select, adapt, and implement EBIs. Training, technical assistance, and…
Tran, Linda Diem
2016-12-01
A difference-in-difference approach was used to compare the effects of same-sex domestic partnership, civil union, and marriage policies on same- and different-sex partners who could have benefitted from their partners' employer-based insurance (EBI) coverage. Same-sex partners had 78% lower odds (Marginal Effect = -21%) of having EBI compared with different-sex partners, adjusting for socioeconomic and health-related factors. Same-sex partners living in states that recognized same-sex marriage or domestic partnership had 89% greater odds of having EBI compared with those in states that did not recognize same-sex unions (ME = 5%). The impact of same-sex legislation on increasing take-up of dependent EBI coverage among lesbians, gay men, and bisexual individuals was modest, and domestic partnership legislation was equally as effective as same-sex marriage in increasing same-sex partner EBI coverage. Extending dependent EBI coverage to same-sex partners can mitigate gaps in coverage for a segment of the lesbians, gay men, and bisexual population but will not eliminate them. © The Author(s) 2016.
Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion sourcea)
NASA Astrophysics Data System (ADS)
Kondo, K.; Yamamoto, T.; Sekine, M.; Okamura, M.
2012-02-01
The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current (˜100 μA) with high charge (˜10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.
Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion source.
Kondo, K; Yamamoto, T; Sekine, M; Okamura, M
2012-02-01
The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current (∼100 μA) with high charge (∼10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.
National Synchrotron Light Source II storage ring vacuum systems
Hseuh, Hsiao-Chaun; Hetzel, Charles; Leng, Shuwei; ...
2016-04-05
The National Synchrotron Light Source II, completed in 2014, is a 3-GeV synchrotron radiation (SR) facility at Brookhaven National Laboratory and has been in steady operation since. With a design electron current of 500 mA and subnanometer radians horizontal emittance, this 792-m circumference storage ring is providing the highest flux and brightness x-ray beam for SR users. Also, the majority of the storage ring vacuum chambers are made of extruded aluminium. Chamber sections are interconnected using low-impedance radiofrequency shielded bellows. SR from the bending magnets is intercepted by water-cooled compact photon absorbers resided in the storage ring chambers. Finally, thismore » paper presents the design of the storage ring vacuum system, the fabrication of vacuum chambers and other hardware, the installation, the commissioning, and the continuing beam conditioning of the vacuum systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ostroumov, P. N.; Barcikowski, A.; Dickerson, C. A.
The Electron Beam Ion Source (EBIS), developed to breed CARIBU radioactive beams at ATLAS, is being tested off-line. A unique property of the EBIS is a combination of short breeding times, high repetition rates and a large acceptance. Overall, we have implemented many innovative features during the design and construction of the CARIBU EBIS as compared to the existing EBIS breeders. The offline charge breeding tests are being performed using a surface ionization source that produces singly-charged cesium ions. The main goal of the off-line commissioning is to demonstrate stable operation of the EBIS at a 10 Hz repetition ratemore » and a breeding efficiency into single charge state higher than 15%. These goals have been successfully achieved and exceeded. We have measured (20±0.7)% breeding efficiency into the single charge state of 28+ cesium ions with the breeding time of 28 ms. In general, the current CARIBU EBIS operational parameters can provide charge breeding of any ions in the full mass range of periodic table with high efficiency, short breeding times and sufficiently low charge-to-mass ratio, 1/6.3 for the heaviest masses, for further acceleration in ATLAS. In this paper we discuss the parameters of the EBIS and the charge breeding results in a pulsed injection mode with repetition rates up to 10 Hz.« less
Dovetailing biology and chemistry: integrating the Gene Ontology with the ChEBI chemical ontology
2013-01-01
Background The Gene Ontology (GO) facilitates the description of the action of gene products in a biological context. Many GO terms refer to chemical entities that participate in biological processes. To facilitate accurate and consistent systems-wide biological representation, it is necessary to integrate the chemical view of these entities with the biological view of GO functions and processes. We describe a collaborative effort between the GO and the Chemical Entities of Biological Interest (ChEBI) ontology developers to ensure that the representation of chemicals in the GO is both internally consistent and in alignment with the chemical expertise captured in ChEBI. Results We have examined and integrated the ChEBI structural hierarchy into the GO resource through computationally-assisted manual curation of both GO and ChEBI. Our work has resulted in the creation of computable definitions of GO terms that contain fully defined semantic relationships to corresponding chemical terms in ChEBI. Conclusions The set of logical definitions using both the GO and ChEBI has already been used to automate aspects of GO development and has the potential to allow the integration of data across the domains of biology and chemistry. These logical definitions are available as an extended version of the ontology from http://purl.obolibrary.org/obo/go/extensions/go-plus.owl. PMID:23895341
Duke storage rink UV/VUV FEL: Status and prospects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Litvinenko, V.N.; Burnham, B.; Madey, J.M.J.
1995-12-31
The 1 GeV Duke storage ring was successfully commissioned with parameters exceeding initial specification. The OK-4 FEL has arrived at the Duke FEL laboratory from the Novosibirsk Institute of Nuclear Physics. The OK-4 installation and commissioning is in progress. In this paper we describe the up-to-date status of the Duke storage ring and the OK-4 FEL. The projected performance of the OK-4 UV/VUV FEL is presented based on the electron beam parameters achieved. Initial plans to operate the OK-4 UV/VUV FEL at the Duke 1 GeV storage ring are outlined. Future plans and prospects of both the OK-4 FEL andmore » the Duke storage ring are discussed.« less
A new storage-ring light source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chao, Alex
2015-06-01
A recently proposed technique in storage ring accelerators is applied to provide potential high-power sources of photon radiation. The technique is based on the steady-state microbunching (SSMB) mechanism. As examples of this application, one may consider a high-power DUV photon source for research in atomic and molecular physics or a high-power EUV radiation source for industrial lithography. A less challenging proof-of-principle test to produce IR radiation using an existing storage ring is also considered.
Polarization Studies for the eRHIC Electron Storage Ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gianfelice-Wendt, Eliana; Tepikian, S.
A hadron/lepton collider with polarized beams has been under consideration by the scientific community since some years, in the U.S. and Europe. Among the various proposals, those by JLAB and BNL with polarized electron and proton beams are currently under closer study in the U.S. Experimenters call for the simultaneous storage of electron bunches with both spin helicity. In the BNL based Ring-Ring design, electrons are stored at top energy in a ring to be accommodated in the existing RHIC tunnel. The transversely polarized electron beam is injected into the storage ring at variable energies, between 5 and 18 GeV.more » Polarization is brought into the longitudinal direction at the IP by a couple of spin rotators. In this paper results of first studies of the attainable beam polarization level and lifetime in the storage ring at 18 GeV are presented.« less
Inertial energy storage device
Knight, Jr., Charles E.; Kelly, James J.; Pollard, Roy E.
1978-01-01
The inertial energy storage device of the present invention comprises a composite ring formed of circumferentially wound resin-impregnated filament material, a flanged hollow metal hub concentrically disposed in the ring, and a plurality of discrete filament bandsets coupling the hub to the ring. Each bandset is formed of a pair of parallel bands affixed to the hub in a spaced apart relationship with the axis of rotation of the hub being disposed between the bands and with each band being in the configuration of a hoop extending about the ring along a chordal plane thereof. The bandsets are disposed in an angular relationship with one another so as to encircle the ring at spaced-apart circumferential locations while being disposed in an overlapping relationship on the flanges of the hub. The energy storage device of the present invention has the capability of substantial energy storage due to the relationship of the filament bands to the ring and the flanged hub.
Early Brain Injury Associated with Systemic Inflammation After Subarachnoid Hemorrhage.
Savarraj, Jude; Parsha, Kaushik; Hergenroeder, Georgene; Ahn, Sungho; Chang, Tiffany R; Kim, Dong H; Choi, H Alex
2018-04-01
Early brain injury (EBI) after aneurysmal subarachnoid hemorrhage (aSAH) is defined as brain injury occurring within 72 h of aneurysmal rupture. Although EBI is the most significant predictor of outcomes after aSAH, its underlying pathophysiology is not well understood. We hypothesize that EBI after aSAH is associated with an increase in peripheral inflammation measured by cytokine expression levels and changes in associations between cytokines. aSAH patients were enrolled into a prospective observational study and were assessed for markers of EBI: global cerebral edema (GCE), subarachnoid hemorrhage early brain edema score (SEBES), and Hunt-Hess grade. Serum samples collected at ≤ 48 h of admission were analyzed using multiplex bead-based assays to determine levels of 13 pro- and anti-inflammatory cytokines. Pairwise correlation coefficients between cytokines were represented as networks. Cytokine levels and differences in correlation networks were compared between EBI groups. Of the 71 patients enrolled in the study, 17 (24%) subjects had GCE, 31 (44%) subjects had SEBES ≥ 3, and 21 (29%) had HH ≥ 4. IL-6 was elevated in groups with GCE, SEBES ≥ 3, and HH ≥ 4. MIP1β was independently associated with high-grade SEBES. Correlation network analysis suggests higher systematic inflammation in subjects with SEBES ≥ 3. EBI after SAH is associated with increased levels of specific cytokines. Peripheral levels of IL-10, IL-6, and MIP1β may be important markers of EBI. Investigating systematic correlations in addition to expression levels of individual cytokines may offer deeper insight into the underlying mechanisms related to EBI.
Extreme Algal Bloom Detection with MERIS
NASA Astrophysics Data System (ADS)
Amin, R.; Gilerson, A.; Gould, R.; Arnone, R.; Ahmed, S.
2009-05-01
Harmful Algal Blooms (HAB's) are a major concern all over the world due to their negative impacts on the marine environment, human health, and the economy. Their detection from space still remains a challenge particularly in turbid coastal waters. In this study we propose a simple reflectance band difference approach for use with Medium Resolution Imaging Spectrometer (MERIS) data to detect intense plankton blooms. For convenience we label this approach as the Extreme Bloom Index (EBI) which is defined as EBI = Rrs (709) - Rrs (665). Our initial analysis shows that this band difference approach has some advantages over the band ratio approaches, particularly in reducing errors due to imperfect atmospheric corrections. We also do a comparison between the proposed EBI technique and the Maximum Chlorophyll Index (MCI) Gower technique. Our preliminary result shows that both the EBI and MCI indeces detect intense plankton blooms, however, MCI is more vulnerable in highly scattering waters, giving more positive false alarms than EBI.
Cederbaum, Julie A; Song, Ahyoung; Hsu, Hsun-Ta; Tucker, Joan S; Wenzel, Suzanne L
2014-11-01
As interest grows in the diffusion of evidence-based interventions (EBIs), there is increasing concern about how to mitigate implementation challenges; this paper concerns adapting an EBI for homeless women. Complementing earlier focus groups with homeless women, homeless service providers (n = 32) were engaged in focus groups to assess capacity, needs, and barriers with implementation of EBIs. Deductive analyses of data led to the selection of four EBIs. Six consensus groups were then undertaken; three each with homeless women (n = 24) and homeless service providers (n = 21). The selected EBI was adapted and pretested with homeless women (n = 9) and service providers (n = 6). The structured consensus group process provided great utility and affirmed the expertise of homeless women and service providers as experts in their domain. Engaging providers in the selection process reduced the structural barriers within agencies as obstacles to diffusion.
Design of the transfer line from booster to storage ring at 3 GeV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bayar, C., E-mail: cafer.bayar@cern.ch; Ciftci, A. K., E-mail: abbas.kenan.ciftci@cern.ch
The Synchrotron Booster Ring accelerates the e-beam up to 3 GeV and particles are transported from booster to storage ring by transfer line. In this study, two options are considered, the first one is a long booster which shares the same tunnel with storage ring and the second one is a compact booster. As a result, two transfer line are designed based on booster options. The optical design is constrained by the e-beam Twiss parameters entering and leaving the transfer line. Twiss parameters in the extraction point of booster are used for the entrance of transfer line and are matchedmore » in the exit of transfer line to the injection point of the storage ring.« less
An Inside Look: NSLS-II Storage Ring
Fries, Gregory
2018-06-12
Look inside the storage ring of the National Synchrotron Light Source II, under construction at Brookhaven Lab. Exactly 843 magnets now encircle the ring. Their job will be to steer, stabilize, and store electrons racing around at near light speed.
ERIC Educational Resources Information Center
Poulsen, Melissa N.; Vandenhoudt, Hilde; Wyckoff, Sarah C.; Obong'o, Christopher O.; Ochura, Juliet; Njika, Gillian; Otwoma, Nelson Juma; Miller, Kim S.
2010-01-01
Evidence-based interventions (EBIs) are critical for effective HIV prevention, but time and resources required to develop and evaluate new interventions are limited. Alternatively, existing EBIs can be adapted for new settings if core elements remain intact. We describe the process of adapting the Parents Matter! Program, an EBI originally…
Ostroumov, P. N.; Barcikowski, A.; Dickerson, C. A.; ...
2015-08-28
The Electron Beam Ion Source (EBIS), developed to breed Californium Rare Isotope Breeder Upgrade (CARIBU) radioactive beams at Argonne Tandem Linac Accelerator System (ATLAS), is being tested off-line. A unique property of the EBIS is a combination of short breeding times, high repetition rates, and a large acceptance. Overall, we have implemented many innovative features during the design and construction of the CARIBU EBIS as compared to the existing EBIS breeders. The off-line charge breeding tests are being performed using a surface ionization source that produces singly charged cesium ions. The main goal of the off-line commissioning is to demonstratemore » stable operation of the EBIS at a 10 Hz repetition rate and a breeding efficiency into single charge state higher than 15%. These goals have been successfully achieved and exceeded. We have measured (20% ± 0.7%) breeding efficiency into the single charge state of 28+ cesium ions with the breeding time of 28 ms. In general, the current CARIBU EBIS operational parameters can provide charge breeding of any ions in the full mass range of periodic table with high efficiency, short breeding times, and sufficiently low charge-to-mass ratio, 1/6.3 for the heaviest masses, for further acceleration in ATLAS. In this study, we discuss the parameters of the EBIS and the charge breeding results in a pulsed injection mode with repetition rates up to 10 Hz.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ostroumov, P. N.; Barcikowski, A.; Dickerson, C. A.
The Electron Beam Ion Source (EBIS), developed to breed Californium Rare Isotope Breeder Upgrade (CARIBU) radioactive beams at Argonne Tandem Linac Accelerator System (ATLAS), is being tested off-line. A unique property of the EBIS is a combination of short breeding times, high repetition rates, and a large acceptance. Overall, we have implemented many innovative features during the design and construction of the CARIBU EBIS as compared to the existing EBIS breeders. The off-line charge breeding tests are being performed using a surface ionization source that produces singly charged cesium ions. The main goal of the off-line commissioning is to demonstratemore » stable operation of the EBIS at a 10 Hz repetition rate and a breeding efficiency into single charge state higher than 15%. These goals have been successfully achieved and exceeded. We have measured (20% ± 0.7%) breeding efficiency into the single charge state of 28+ cesium ions with the breeding time of 28 ms. In general, the current CARIBU EBIS operational parameters can provide charge breeding of any ions in the full mass range of periodic table with high efficiency, short breeding times, and sufficiently low charge-to-mass ratio, 1/6.3 for the heaviest masses, for further acceleration in ATLAS. In this study, we discuss the parameters of the EBIS and the charge breeding results in a pulsed injection mode with repetition rates up to 10 Hz.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ostroumov, P. N., E-mail: ostroumov@anl.gov; Barcikowski, A.; Dickerson, C. A.
The Electron Beam Ion Source (EBIS), developed to breed Californium Rare Isotope Breeder Upgrade (CARIBU) radioactive beams at Argonne Tandem Linac Accelerator System (ATLAS), is being tested off-line. A unique property of the EBIS is a combination of short breeding times, high repetition rates, and a large acceptance. Overall, we have implemented many innovative features during the design and construction of the CARIBU EBIS as compared to the existing EBIS breeders. The off-line charge breeding tests are being performed using a surface ionization source that produces singly charged cesium ions. The main goal of the off-line commissioning is to demonstratemore » stable operation of the EBIS at a 10 Hz repetition rate and a breeding efficiency into single charge state higher than 15%. These goals have been successfully achieved and exceeded. We have measured (20% ± 0.7%) breeding efficiency into the single charge state of 28+ cesium ions with the breeding time of 28 ms. In general, the current CARIBU EBIS operational parameters can provide charge breeding of any ions in the full mass range of periodic table with high efficiency, short breeding times, and sufficiently low charge-to-mass ratio, 1/6.3 for the heaviest masses, for further acceleration in ATLAS. In this paper, we discuss the parameters of the EBIS and the charge breeding results in a pulsed injection mode with repetition rates up to 10 Hz.« less
Electrical bioimpedance enabling prompt intervention in traumatic brain injury
NASA Astrophysics Data System (ADS)
Seoane, Fernando; Atefi, S. Reza
2017-05-01
Electrical Bioimpedance (EBI) is a well spread technology used in clinical practice across the world. Advancements in Textile material technology with conductive textile fabrics and textile-electronics integration have allowed exploring potential applications for Wearable Measurement Sensors and Systems exploiting. The sensing principle of electrical bioimpedance is based on the intrinsic passive dielectric properties of biological tissue. Using a pair of electrodes, tissue is electrically stimulated and the electrical response can be sensed with another pair of surface electrodes. EBI spectroscopy application for cerebral monitoring of neurological conditions such as stroke and perinatal asphyxia in newborns have been justified using animal studies and computational simulations. Such studies have shown proof of principle that neurological pathologies indeed modify the dielectric composition of the brain that is detectable via EBI. Similar to stroke, Traumatic Brain Injury (TBI) also affects the dielectric properties of brain tissue that can be detected via EBI measurements. Considering the portable and noninvasive characteristics of EBI it is potentially useful for prehospital triage of TBI patients where. In the battlefield blast induced Traumatic Brain Injuries are very common. Brain damage must be assessed promptly to have a chance to prevent severe damage or eventually death. The relatively low-complexity of the sensing hardware required for EBI sensing and the already proven compatibility with textile electrodes suggest the EBI technology is indeed a candidate for developing a handheld device equipped with a sensorized textile cap to produce an examination in minutes for enabling medically-guided prompt intervention.
Diffraction-limited storage-ring vacuum technology
Al-Dmour, Eshraq; Ahlback, Jonny; Einfeld, Dieter; Tavares, Pedro Fernandes; Grabski, Marek
2014-01-01
Some of the characteristics of recent ultralow-emittance storage-ring designs and possibly future diffraction-limited storage rings are a compact lattice combined with small magnet apertures. Such requirements present a challenge for the design and performance of the vacuum system. The vacuum system should provide the required vacuum pressure for machine operation and be able to handle the heat load from synchrotron radiation. Small magnet apertures result in the conductance of the chamber being low, and lumped pumps are ineffective. One way to provide the required vacuum level is by distributed pumping, which can be realised by the use of a non-evaporable getter (NEG) coating of the chamber walls. It may not be possible to use crotch absorbers to absorb the heat from the synchrotron radiation because an antechamber is difficult to realise with such a compact lattice. To solve this, the chamber walls can work as distributed absorbers if they are made of a material with good thermal conductivity, and distributed cooling is used at the location where the synchrotron radiation hits the wall. The vacuum system of the 3 GeV storage ring of MAX IV is used as an example of possible solutions for vacuum technologies for diffraction-limited storage rings. PMID:25177979
ONLINE MINIMIZATION OF VERTICAL BEAM SIZES AT APS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Yipeng
In this paper, online minimization of vertical beam sizes along the APS (Advanced Photon Source) storage ring is presented. A genetic algorithm (GA) was developed and employed for the online optimization in the APS storage ring. A total of 59 families of skew quadrupole magnets were employed as knobs to adjust the coupling and the vertical dispersion in the APS storage ring. Starting from initially zero current skew quadrupoles, small vertical beam sizes along the APS storage ring were achieved in a short optimization time of one hour. The optimization results from this method are briefly compared with the onemore » from LOCO (Linear Optics from Closed Orbits) response matrix correction.« less
ERIC Educational Resources Information Center
Galbraith, Jennifer S.; Stanton, Bonita; Boekeloo, Bradley; King, Winifred; Desmond, Sharon; Howard, Donna; Black, Maureen M.; Carey, James W.
2009-01-01
Evidence-based interventions (EBIs) are used in public health to prevent HIV infection among youth and other groups. EBIs include core elements, features that are thought to be responsible for the efficacy of interventions. The authors evaluate experiences of organizations that adopted an HIV-prevention EBI, Focus on Kids (FOK), and their fidelity…
NASA Astrophysics Data System (ADS)
Leemann, S. C.; Wurtz, W. A.
2018-03-01
The MAX IV 3 GeV storage ring is presently being commissioned and crucial parameters such as machine functions, emittance, and stored current have either already been reached or are approaching their design specifications. Once the baseline performance has been achieved, a campaign will be launched to further improve the brightness and coherence of this storage ring for typical X-ray users. During recent years, several such improvements have been designed. Common to these approaches is that they attempt to improve the storage ring performance using existing hardware provided for the baseline design. Such improvements therefore present more short-term upgrades. In this paper, however, we investigate medium-term improvements assuming power supplies can be exchanged in an attempt to push the brightness and coherence of the storage ring to the limit of what can be achieved without exchanging the magnetic lattice itself. We outline optics requirements, the optics optimization process, and summarize achievable parameters and expected performance.
Cabling design of booster and storage ring construction progress of TPS
NASA Astrophysics Data System (ADS)
Wong, Y.-S.; Liu, K.-B.; Liu, C.-Y.; Wang, b.-S.
2017-06-01
The 2012 Taiwan Photon Source (TPS) cable construction project started after 10 months to complete the cable laying and installation of power supply. The circumference of the booster ring (BR) is 496.8 m, whereas that of the storage ring (SR) is 518.4 m. Beam current is set to 500 mA at 3.3 GeV. The paper on grounding systems discusses the design of the ground wire (< 0.2 Ω) with low impedance, power supply of the accelerator and cabling tray. The flow and size of the ground current are carefully evaluated to avoid grounded current from flowing everywhere, which causes interference problems. In the design of the TPS, special shielding will be established to isolate the effects of electromagnetic interference on the magnet and ground current. Booster ring dipoles are connected by a series of 54-magnet bending dipole; the cable size of its stranded wire measures 250 mm2, with a total length of 5000 m. Booster ring and storage ring quadrupoles have 150 magnets; the cable size of their stranded wire is 250 mm2, with a total length of 17000 m. Storage ring dipole consists of 48 magnets; the cable size of its stranded wire is 325 mm2, with a total length of 6000 m. This study discusses the power supply cabling design of the storage ring and booster ring construction progress of TPS. The sections of this paper are divided into discussions of the construction of the control and instrument area, cabling layout of booster ring and storage ring, as well as the installation and commission machine. This study also discusses the use of a high-impedance meter to determine the effect of cabling insulation and TPS power supply machine on energy transfer to ensure the use of safe and correct magnet.
InterProScan 5: genome-scale protein function classification
Jones, Philip; Binns, David; Chang, Hsin-Yu; Fraser, Matthew; Li, Weizhong; McAnulla, Craig; McWilliam, Hamish; Maslen, John; Mitchell, Alex; Nuka, Gift; Pesseat, Sebastien; Quinn, Antony F.; Sangrador-Vegas, Amaia; Scheremetjew, Maxim; Yong, Siew-Yit; Lopez, Rodrigo; Hunter, Sarah
2014-01-01
Motivation: Robust large-scale sequence analysis is a major challenge in modern genomic science, where biologists are frequently trying to characterize many millions of sequences. Here, we describe a new Java-based architecture for the widely used protein function prediction software package InterProScan. Developments include improvements and additions to the outputs of the software and the complete reimplementation of the software framework, resulting in a flexible and stable system that is able to use both multiprocessor machines and/or conventional clusters to achieve scalable distributed data analysis. InterProScan is freely available for download from the EMBl-EBI FTP site and the open source code is hosted at Google Code. Availability and implementation: InterProScan is distributed via FTP at ftp://ftp.ebi.ac.uk/pub/software/unix/iprscan/5/ and the source code is available from http://code.google.com/p/interproscan/. Contact: http://www.ebi.ac.uk/support or interhelp@ebi.ac.uk or mitchell@ebi.ac.uk PMID:24451626
Silze, Alexandra; Ritter, Erik; Zschornack, Günter; Schwan, Andreas; Ullmann, Falk
2010-02-01
We have characterized ion beams extracted from the Dresden EBIS-A, a compact room-temperature electron beam ion source (EBIS) with a permanent magnet system for electron beam compression, using a pepper-pot emittance meter. The EBIS-A is the precursor to the Dresden EBIS-SC in which the permanent magnets have been replaced by superconducting solenoids for the use of the source in high-ion-current applications such as heavy-ion cancer therapy. Beam emittance and brightness values were calculated from data sets acquired for a variety of source parameters, in leaky as well as pulsed ion extraction mode. With box shaped pulses of C(4+) ions at an energy of 39 keV root mean square emittances of 1-4 mm mrad and a brightness of 10 nA mm(-2) mrad(-2) were achieved. The results meet the expectations for high quality ion beams generated by an electron beam ion source.
Impact of Human Resources on Implementing an Evidence-based HIV Prevention Intervention
McKay, Virginia R.; Dolcini, M. Margaret; Catania, Joseph A.
2016-01-01
Evidence-based interventions (EBIs) often require competent staff, or human resources (HR), for implementation. The empirical evidence characterizing the influence of HR fluctuations on EBI delivery is limited and conflicting. Using the Interactive Systems Framework, we explored staff fluctuation and the subsequent influence on RESPECT, an HIV prevention EBI. Methods We conducted interviews with staff in two waves (n=53, Wave I; n=37, Wave II) in a national sample of organizations delivering RESPECT (N=29). We analyzed interviews qualitatively to describe changes among RESPECT staff and explore the subsequent influences on RESPECT implementation. Results Organizations reported downsizing, turnover, and expansion of staff positions. Staff changes had multiple influences on RESPECT implementation including clients reached, fidelity to specific RESPECT protocols, and overall sustainability of RESPECT over time. Discussion HR fluctuations are common, and our analyses provide an initial characterization of the relationship between HR fluctuation and EBI implementation. Given the prominent influence of HR on EBI implementation, the Interactive Systems Framework is a useful guiding tool for future examinations. PMID:27150896
Signaling Pathway in Early Brain Injury after Subarachnoid Hemorrhage: News Update.
Ji, Chengyuan; Chen, Gang
2016-01-01
The annual incidence of subarachnoid hemorrhage (SAH) caused by intracranial aneurysm rupture is approximately 10.5/10 million people in China, making SAH the third most frequently occurring hemorrhage of the intracranial type after cerebral embolism and hypertensive intracerebral hemorrhage. SAH caused by ruptured aneurysm leads to a mortality rate as high as 67 %, and, because of the sudden onset of this disease, approximately 12-15 % of patients die before they can receive effective treatment. Early brain injury (EBI) is the brain damage occurring within the first 72 h after SAH. Two-thirds of mortality caused by SAH occurs within 48 h, mainly as a result of EBI. With the development of molecular biology and medicine microscopy techniques, various signaling pathways involved in EBI after SAH have been revealed. Understanding these signaling pathways may help clinicians treat EBI after SAH and improve long-term prognosis of SAH patients. This chapter summarizes several important signaling pathways implicated in EBI caused by SAH.
NASA Technical Reports Server (NTRS)
Duncan, Sharon L.
2011-01-01
Enterprise Business Information Services Division (EBIS) supports the Laboratory and its functions through the implementation and support of business information systems on behalf of its business community. EBIS Five Strategic Focus Areas: (1) Improve project estimating, planning and delivery capability (2) Improve maintainability and sustainability of EBIS Application Portfolio (3) Leap forward in IT Leadership (4) Comprehensive Talent Management (5) Continuous IT Security Program. Portfolio Management is a strategy in which software applications are managed as assets
Coupled beam motion in a storage ring with crab cavities
Huang, Xiaobiao
2016-02-16
We studied the coupled beam motion in a storage ring between the transverse and longitudinal directions introduced by crab cavities. Analytic form of the linear decoupling transformation is derived. Also, the equilibrium bunch distribution in an electron storage ring with a crab cavity is given, including contribution to the eigen-emittance induced by the crab cavity. Furthermore, application to the short pulse generation scheme using crab cavities [1] is considered.
A multiple-orbit time-of-flight mass spectrometer based on a low energy electrostatic storage ring
NASA Astrophysics Data System (ADS)
Sullivan, M. R.; Spanjers, T. L.; Thorn, P. A.; Reddish, T. J.; Hammond, P.
2012-11-01
The results are presented for an electrostatic storage ring, consisting of two hemispherical deflector analyzers (HDA) connected by two separate sets of cylindrical lenses, used as a time-of-flight mass spectrometer. Based on the results of charged particle simulations and formal matrix model, the Ion Storage Ring is capable of operating with multiple stable orbits, for both single and multiply charged ions simultaneously.
RF System Requirements for a Medium-Energy Electron-Ion Collider (MEIC) at JLab
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rimmer, Robert A; Hannon, Fay E; Guo, Jiquan
2015-09-01
JLab is studying options for a medium energy electron-ion collider that could fit on the JLab site and use CEBAF as a full-energy electron injector. A new ion source, linac and booster would be required, together with collider storage rings for the ions and electrons. In order to achieve the maximum luminosity these will be high-current storage rings with many bunches. We present the high-level RF system requirements for the storage rings, ion booster ring and high-energy ion beam cooling system, and describe the technology options under consideration to meet them. We also present options for staging that might reducemore » the initial capital cost while providing a smooth upgrade path to a higher final energy. The technologies under consideration may also be useful for other proposed storage ring colliders or ultimate light sources.« less
Decreased interleukin 35 and CD4+EBI3+ T cells in patients with active systemic lupus erythematosus.
Ouyang, Han; Shi, Yong-Bing; Liu, Zhi-Chun; Wang, Zhi; Feng, Sheng; Kong, Shu-Min; Lu, Ying
2014-08-01
Interleukin 35 (IL-35) is likely to contribute to the development of autoimmune diseases, as the Epstein-Barr virus-induced gene protein 3 (EBI3) is the specificity subunit of IL-35. Nevertheless, until recently, no studies have evaluated its role in systemic lupus erythematosus (SLE) in humans. The objective of this study was to investigate the serum IL-35 level and the percentage of CD4EBI3 T cells in the peripheral blood of patients with SLE and explore the roles of double-positive T cells and IL-35 in the pathogenesis of SLE and the effects of glucocorticoid on these roles. Fifty-five hospitalized patients with SLE were recruited, and 20 volunteers were enrolled as healthy controls. Serum IL-35 levels were measured by enzyme-linked immunosorbent assay, and the percentage of CD4EBI3 T cells was analyzed by flow cytometry. The serum IL-35 level and the percentage of CD4EBI3 T cells were significantly decreased in patients with active SLE compared with healthy controls and patients with inactive SLE. The serum IL-35 level and the percentage of CD4EBI3 T cells were negatively correlated with the SLE disease activity index. The percentages of CD4EBI3 T cells and serum IL-35 levels in 10 untreated patients with active SLE were increased at days l, 3, and 7 after the treatment with methylprednisolone (0.8 mg·kg·d) compared with the percentages before the treatment. These results demonstrate that abnormalities in IL-35 and CD4EBI3 T cells may play important roles in the pathogenesis of SLE; the percentage of double-positive T cells and the level of IL-35 are parameters for the evaluation of SLE activity and severity.
Ionization of polarized 3He+ ions in EBIS trap with slanted electrostatic mirror.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pikin,A.; Zelenski, A.; Kponou, A.
2007-09-10
Methods of producing the nuclear polarized {sup 3}He{sup +} ions and their ionization to {sup 3}H{sup ++} in ion trap of the electron Beam Ion Source (EBIS) are discussed. Computer simulations show that injection and accumulation of {sup 3}He{sup +} ions in the EBIS trap with slanted electrostatic mirror can be very effective for injection times longer than the ion traversal time through the trap.
Ionization of polarized {sup 3}He{sup +} ions in EBIS trap with slanted electrostatic mirror
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pikin, A.; Zelenski, A.; Kponou, A.
2008-02-06
Methods of producing the nuclear polarized {sup 3}He{sup +} ions and their ionization to {sup 3}He{sup ++} in ion trap of the electron Beam Ion Source (EBIS) are discussed. Computer simulations show that injection and accumulation of {sup 3}He{sup +} ions in the EBIS trap with slanted electrostatic mirror can be very effective for injection times longer than the ion traversal time through the trap.
The new NHGRI-EBI Catalog of published genome-wide association studies (GWAS Catalog)
MacArthur, Jacqueline; Bowler, Emily; Cerezo, Maria; Gil, Laurent; Hall, Peggy; Hastings, Emma; Junkins, Heather; McMahon, Aoife; Milano, Annalisa; Morales, Joannella; Pendlington, Zoe May; Welter, Danielle; Burdett, Tony; Hindorff, Lucia; Flicek, Paul; Cunningham, Fiona; Parkinson, Helen
2017-01-01
The NHGRI-EBI GWAS Catalog has provided data from published genome-wide association studies since 2008. In 2015, the database was redesigned and relocated to EMBL-EBI. The new infrastructure includes a new graphical user interface (www.ebi.ac.uk/gwas/), ontology supported search functionality and an improved curation interface. These developments have improved the data release frequency by increasing automation of curation and providing scaling improvements. The range of available Catalog data has also been extended with structured ancestry and recruitment information added for all studies. The infrastructure improvements also support scaling for larger arrays, exome and sequencing studies, allowing the Catalog to adapt to the needs of evolving study design, genotyping technologies and user needs in the future. PMID:27899670
Numerical simulation of ion charge breeding in electron beam ion source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, L., E-mail: zhao@far-tech.com; Kim, Jin-Soo
2014-02-15
The Electron Beam Ion Source particle-in-cell code (EBIS-PIC) tracks ions in an EBIS electron beam while updating electric potential self-consistently and atomic processes by the Monte Carlo method. Recent improvements to the code are reported in this paper. The ionization module has been improved by using experimental ionization energies and shell effects. The acceptance of injected ions and the emittance of extracted ion beam are calculated by extending EBIS-PIC to the beam line transport region. An EBIS-PIC simulation is performed for a Cs charge-breeding experiment at BNL. The charge state distribution agrees well with experiments, and additional simulation results ofmore » radial profiles and velocity space distributions of the trapped ions are presented.« less
Effects of CSR Generated from Upstream Bends in a Laser Plasma Storage Ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitchell, C.; Qiang, J.; Venturini, M.
The recent proposal [1] of a Laser Plasma Storage Ring (LPSR) envisions the use of a laser-plasma (LP) acceleration module to inject an electron beam into a compact 500 MeV storage ring. Electron bunches generated by LP methods are naturally very short (tens of femtoseconds), presenting peak currents on the order of 10 kA or higher. Of obvious concern is the impact of collective effects and in particular Coherent Synchrotron Radiation (CSR) on the beam dynamics in the storage ring. Available simulation codes (e.g. Elegant [2]) usually include transient CSR effects but neglect the contribution of radiation emitted from trailingmore » magnets. In a compact storage ring, with dipole magnets close to each other, cross talking between different magnets could in principle be important.In this note we investigate this effect for the proposed LPSR and show that, in fact, this effect is relatively small. However our analysis also indicates that CSR effects in general would be quite strong and deserve a a careful study.« less
David W. Vahey; C. Tim Scott; J.Y. Zhu; Kenneth E. Skog
2012-01-01
Methods for estimating present and future carbon storage in trees and forests rely on measurements or estimates of tree volume or volume growth multiplied by specific gravity. Wood density can vary by tree ring and height in a tree. If data on density by tree ring could be obtained and linked to tree size and stand characteristics, it would be possible to more...
Storage rings, internal targets and PEP
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spencer, J.E.
Storage rings with internal targets are described, using PEP as an example. The difference between electrons and heavier particles such as protons, antiprotons, and heavy ions is also discussed because it raises possibilities of bypass insertions for more exotic experiments. PEP is compared to other rings in various contexts to verify the assertion that it is an ideal ring for many fundamental and practical applications that can be carried on simultaneously. (LEW)
ELISA - an electrostatic storage ring for low-energy ions
NASA Astrophysics Data System (ADS)
Pape Moeller, Soeren
1997-05-01
The design of a new type of storage ring for low-energy ions using electrostatic deflection and focusing devices is described. Electrostatic bends and quadrupoles are used since they are more efficient than magnetic ones for low-velocity heavy ions. Furthermore, electrostatic devices are more compact and easier to construct than magnetic devices. In comparison to an electromagnetic trap, one important advantage of the elecrostatic ring is the easy access to the circulating beam and its decay products. These and other features, e.g. no magnetic fields, makes such storage devices attractive for many atomic-physics experiments. Also neigboring fields as chemistry and biology might benefit from such an relatively inexpensive device. One important difference between an electrostatic and a magnetic ring is, that the longitudinal energy is not conserved for the electrostatic ring. The actual ring will have a race-track shape as defined by two straight sections each with two quadrupole doublets connected by 180-degrees bends. The bends will consist of 160-degrees spherical deflection plates surrounded by two parallel plate 10-degrees bends. The storage ring ELISA, currently being built, will have a circumference of 6 meters. The first beam tests will take place during summer 1996.
Beam diagnostics at high-intensity storage rings
NASA Astrophysics Data System (ADS)
Plum, Mike
1994-10-01
Beam diagnostics at high-intensity facilities feature their own special set of problems and characteristics, issues peculiar to high-intensity storage rings include beam loss, beam halos, extraction efficiency, beam in the gap, clearing electrodes, and beam-profile measurement. The Los Alamos Proton Storage Ring (PSR) is a nice example of a high-intensity storage ring. I will discuss in some detail three diagnostic systems currently in use at the PSR: the beam-loss-monitor system, the electron-clearing system, and the beam-in-the-gap monitor. Much of our discussion is inspired by the problems we have encountered and the useful things we have learned while commissioning and developing the PSR. Another inspiration is our work on the next-generation neutron-spallation source, also known as the National Center for Neutron Research (NCNR).
NASA Astrophysics Data System (ADS)
Riemann, Bernard; Grete, Patrick; Weis, Thomas
2011-06-01
Multiturn (or turn-by-turn) data acquisition has proven to be a new source of direct measurements for Twiss parameters in storage rings. On the other hand, closed-orbit measurements are a long-known tool for analyzing closed-orbit perturbations with conventional beam position monitor (BPM) systems and are necessarily available at every storage ring. This paper aims at combining the advantages of multiturn measurements and closed-orbit data. We show that only two multiturn BPMs and four correctors in one localized drift space in the storage ring (diagnostic drift) are sufficient for model-independent and absolute measuring of β and φ functions at all BPMs, including the conventional ones, instead of requiring all BPMs being equipped with multiturn electronics.
Study of Storage Ring Free-Electron Laser Using Experimental and Simulation Approaches
NASA Astrophysics Data System (ADS)
Jia, Botao
2011-12-01
The Duke electron storage ring, first commissioned in November of 1994, has been developed as a dedicated driver for storage ring free-electron lasers (SRFELs) operating in a wide wavelength range from infrared, to visible, to ultraviolet (UV) and vacuum ultraviolet (VUV). The storage ring has a long straight section for various insertion devices and can be operated in a wide energy range (0.25 GeV to 1.15 GeV). Commissioned in 1995, the first free-electron laser (FEL) on the Duke storage ring was the OK-4 FEL, an optical klystron with two planar undulators sandwiching a buncher magnet. In 2005, the OK-5 FEL with two helical undulators was commissioned. Operating four undulators---two OK-4 and two OK-5 undulators, the world's first distributed optical klystron FEL was brought to operation in 2005. Via Compton scattering of FEL photons and electrons in the storage ring, the Duke FEL drives the world's most powerful, nearly monochromatic, and polarized Compton gamma-ray source, the High Intensity Gamma-ray Source (HIgammaS). Today, a variety of configurations of the storage ring FELs at Duke have been used in a wide range of research areas from nuclear physics to biophysics, from chemical and medical research to industrial applications. The capability of accurately measuring the storage ring electron beam energy spread is crucial for understanding the longitudinal beam dynamics and the dynamics of the storage ring FEL. In this dissertation, we have successfully developed a noninvasive, versatile, and accurate method to measure the energy spread using optical klystron radiation. Novel numerical methods based upon the Gauss-Hermite expansion have been developed to treat both spectral broadening and modulation on an equal footing. Through properly configuring the optical klystron, this energy spread measurement method has a large dynamic range. In addition, a model-based scheme has been developed for correcting the electron beam emittance related inhomogeneous spectral broadening effect, to further enhance the accuracy of measuring the electron beam energy spread. Taking advantage of the direct measurement method of the electron beam energy spread, we have developed another novel technique to simultaneously measure the FEL power, electron beam energy spread, and other beam parameters. This allowed us to study the FEL power in a systematic manner for the first time. Based on the experimental findings and results of the theoretical predictions, we have proposed a compact formula to predict the FEL power using only the knowledge of electron beam current, beam energy, and bunch length. As part of the dissertation work, we have developed a self-consistent numerical model to study the storage ring FEL. The simulation program models the electron beam propagation along the storage ring, multi-turn FEL interaction in the undulators, gradual intra-cavity optical power buildup, etc. This simulation code captures the main features of a storage ring FEL at different time and space scales. The simulated FEL gain has been benchmarked against measured gain and calculated gain with good agreement. The simulation package can provide comprehensive information about the FEL gain, optical pulse growth, electron beam properties, etc. In the near future, we plan to further improve the simulation model, by including additional physics effects such as microwave instability, to make it a more useful tool for FEL research.
Development of an EBIS charge breeder for the Rare Isotope Science Project
NASA Astrophysics Data System (ADS)
Son, Hyock-Jun; Park, Young-Ho; Kondrashev, Sergey; Kim, Jongwon; Lee, Bong Ju; Chung, Moses
2017-10-01
In Korea, a heavy ion accelerator facility called RAON is being designed to produce various rare isotopes for the Rare Isotope Science Project (RISP) (Jeong, 2016) [1], (Moon, 2014) [2]. This facility is designed to use both In-flight Fragment (IF) and Isotope Separation On-Line (ISOL) techniques in order to produce a wide variety of RI beams for nuclear physics experiments. An Electron Beam Ion Source (EBIS) will be used for charge breeding of Rare Isotope (RI) beams in the ISOL system. The charge-to-mass ratio (q/A) of the RI beams after charge breeding is ≥1/4. The highly charged RI beams will be accelerated by a linac post-accelerator and delivered to a low energy (∼18 MeV/u) experimental hall or the IF system. The RAON EBIS will use a 3 A electron gun and a 6 T superconducting solenoid for high capacity, high efficiency, and short breeding time. In front of the charge breeder, an RFQ cooler-buncher will be used to deliver a bunched beam with small emittance to the EBIS charge breeder. The main design of the RAON EBIS has been carried out on the basis of several beam analyses and technical reviews. In this paper, current progress of the development of the RAON EBIS charge breeder will be presented.
Electrical bioimpedance and other techniques for gastric emptying and motility evaluation
Huerta-Franco, María Raquel; Vargas-Luna, Miguel; Montes-Frausto, Juana Berenice; Flores-Hernández, Corina; Morales-Mata, Ismael
2012-01-01
The aim of this article is to identify non-invasive, inexpensive, highly sensitive and accurate techniques for evaluating and diagnosing gastric diseases. In the case of the stomach, there are highly sensitive and specific methods for assessing gastric motility and emptying (GME). However, these methods are invasive, expensive and/or not technically feasible for all clinicians and patients. We present a summary of the most relevant international information on non-invasive methods and techniques for clinically evaluating GME. We particularly emphasize the potential of gastric electrical bioimpedance (EBI). EBI was initially used mainly in gastric emptying studies and was essentially abandoned in favor of techniques such as electrogastrography and the gold standard, scintigraphy. The current research evaluating the utility of gastric EBI either combines this technique with other frequently used techniques or uses new methods for gastric EBI signal analysis. In this context, we discuss our results and those of other researchers who have worked with gastric EBI. In this review article, we present the following topics: (1) a description of the oldest methods and procedures for evaluating GME; (2) an explanation of the methods currently used to evaluate gastric activity; and (3) a perspective on the newest trends and techniques in clinical and research GME methods. We conclude that gastric EBI is a highly effective non-invasive, easy to use and inexpensive technique for assessing GME. PMID:22368782
Single-pass BPM system of the Photon Factory storage ring.
Honda, T; Katoh, M; Mitsuhashi, T; Ueda, A; Tadano, M; Kobayashi, Y
1998-05-01
At the 2.5 GeV ring of the Photon Factory, a single-pass beam-position monitor (BPM) system is being prepared for the storage ring and the beam transport line. In the storage ring, the injected beam position during the first several turns can be measured with a single injection pulse. The BPM system has an adequate performance, useful for the commissioning of the new low-emittance lattice. Several stripline BPMs are being installed in the beam transport line. The continuous monitoring of the orbit in the beam transport line will be useful for the stabilization of the injection energy as well as the injection beam orbit.
ChEBI in 2016: Improved services and an expanding collection of metabolites
Hastings, Janna; Owen, Gareth; Dekker, Adriano; Ennis, Marcus; Kale, Namrata; Muthukrishnan, Venkatesh; Turner, Steve; Swainston, Neil; Mendes, Pedro; Steinbeck, Christoph
2016-01-01
ChEBI is a database and ontology containing information about chemical entities of biological interest. It currently includes over 46 000 entries, each of which is classified within the ontology and assigned multiple annotations including (where relevant) a chemical structure, database cross-references, synonyms and literature citations. All content is freely available and can be accessed online at http://www.ebi.ac.uk/chebi. In this update paper, we describe recent improvements and additions to the ChEBI offering. We have substantially extended our collection of endogenous metabolites for several organisms including human, mouse, Escherichia coli and yeast. Our front-end has also been reworked and updated, improving the user experience, removing our dependency on Java applets in favour of embedded JavaScript components and moving from a monthly release update to a ‘live’ website. Programmatic access has been improved by the introduction of a library, libChEBI, in Java, Python and Matlab. Furthermore, we have added two new tools, namely an analysis tool, BiNChE, and a query tool for the ontology, OntoQuery. PMID:26467479
Electron beam induced etching of carbon nanotubes enhanced by secondary electrons in oxygen.
Yoshida, Hideto; Tomita, Yuto; Soma, Kentaro; Takeda, Seiji
2017-05-12
Multi-walled carbon nanotubes (CNTs) are subjected to electron-beam-induced etching (EBIE) in oxygen. The EBIE process is observed in situ by environmental transmission electron microscopy. The partial pressure of oxygen (10 and 100 Pa), energy of the primary electrons (80 and 200 keV), and environment of the CNTs (suspended or supported on a silicon nitride membrane) are investigated as factors affecting the etching rate. The EBIE rate of CNTs was markedly promoted by the effects of secondary electrons that were emitted from a silicon nitride membrane under irradiation by primary electrons. Membrane supported CNTs can be cut by EBIE with a spatial accuracy better than 3 nm, and a nanogap of 2 nm can be successfully achieved between the ends of two suspended CNTs.
REQUIREMENTS AND GUIDELINES FOR NSLS EXPERIMENTAL BEAM LINE VACUUM SYSTEMS-REVISION B.
DOE Office of Scientific and Technical Information (OSTI.GOV)
FOERSTER,C.
Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas aftermore » a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ring where for most experiments, windows are not used. For the shorter wavelength, more energetic photons of the x-ray ring, beryllium windows are used at various beam line locations so that the monochromator, mirror box or sample chamber may be used in a helium atmosphere or rough vacuum. The window separates ring vacuum from the environment of the downstream beam line components. The stored beam lifetime in the storage rings and the maintenance of desirable reflection properties of optical surfaces depend upon hydrocarbon-free, ultra-high vacuum systems. Storage ring vacuum systems will operate at pressures of {approximately} 1 x 10{sup {minus}10} Torr without beam and {approximately} 1 x 10{sup {minus}9} Torr with beam. Systems are free of hydrocarbons in the sense that no pumps, valves, etc. containing organics are used. Components are all-metal, chemically cleaned and bakeable. To the extent that beam lines share a common vacuum with the storage ring, the same criteria will hold for beam line components. The design philosophy for NSLS beam lines is to use all-metal, hydrocarbon-free front end components and recommend that experimenters use this approach for common vacuum hardware downstream of front ends. O-ring-sealed valves, if used, are not permitted upstream of the monochromator exit aperture. It will be the responsibility of users to demonstrate that their experiment will not degrade the pressure or quality of the storage ring vacuum. As a matter of operating policy, all beam lines will be monitored for prescribed pressure and the contribution of high mass gases to this pressure each time a beam line has been opened to ring vacuum.« less
Low-emittance tuning of storage rings using normal mode beam position monitor calibration
NASA Astrophysics Data System (ADS)
Wolski, A.; Rubin, D.; Sagan, D.; Shanks, J.
2011-07-01
We describe a new technique for low-emittance tuning of electron and positron storage rings. This technique is based on calibration of the beam position monitors (BPMs) using excitation of the normal modes of the beam motion, and has benefits over conventional methods. It is relatively fast and straightforward to apply, it can be as easily applied to a large ring as to a small ring, and the tuning for low emittance becomes completely insensitive to BPM gain and alignment errors that can be difficult to determine accurately. We discuss the theory behind the technique, present some simulation results illustrating that it is highly effective and robust for low-emittance tuning, and describe the results of some initial experimental tests on the CesrTA storage ring.
Ebi3 Prevents Trypanosoma cruzi-Induced Myocarditis by Dampening IFN-γ-Driven Inflammation.
Medina, Tiago Silva; Oliveira, Gabriela Gonçalves; Silva, Maria Cláudia; David, Bruna Araújo; Silva, Grace Kelly; Fonseca, Denise Morais; Sesti-Costa, Renata; Frade, Amanda Farage; Baron, Monique Andrade; Ianni, Barbara; Pereira, Alexandre Costa; Chevillard, Christophe; Cunha-Neto, Edécio; Marin-Neto, José Antonio; Silva, João Santana
2017-01-01
The identification of anti-inflammatory mediators can reveal important targetable molecules capable of counterbalancing Trypanosoma cruzi -induced myocarditis. Composed of Ebi3 and IL-27p28 subunits, IL-27 is produced by myeloid cells and is able to suppress inflammation by inducing IL-10-producing Tr1 cells, thus emerging as a potential candidate to ameliorate cardiac inflammation induced by T. cruzi . Although IL-27 has been extensively characterized as a suppressive cytokine that prevents liver immunopathogenesis after T. cruzi infection, the mechanisms underlying its effects on T. cruzi -induced myocarditis remain largely unknown. Here, wild-type (WT) and Ebi3-deficient animals were intraperitoneally infected with trypomastigotes of T. cruzi Y strain and used to evaluate the potential anti-inflammatory properties of Ebi3 during T. cruzi infection. The survival rates of mice were daily recorded, the frequency of inflammatory cells was analyzed by flow cytometry and inflammatory mediators were measured by ELISA, real-time PCR and PCR array. We reported that T. cruzi -induced myocarditis was prevented by Ebi3. Stressors mainly recognized by TLR2 and TLR4 receptors on myeloid cells were essential to trigger IL-27p28 production. In addition, Ebi3 regulated IFN-γ-mediated myocarditis by promoting an anti-inflammatory environment through IL-10, which was most likely produced by Tr1 cells rather than classical regulatory T cells (Tregs), in the heart tissue of T. cruzi -infected animals. Furthermore, in vivo IFN-γ blockade ameliorated the host survival without compromising the parasite control in the bloodstream. In humans, IL-27p28 was correlated with cardiac protection during Chagas disease. Patients with mild clinical forms of the disease produced high levels of IL-27p28, whereas lower levels were found in those with severe forms. In addition, polymorphic sites at Ebi3 gene were associated with severe cardiomyopathy in patients with Chagas disease. Collectively, we describe a novel regulatory mechanism where Ebi3 dampens cardiac inflammation by modulating the overproduction of IFN-γ, the bona fide culprit of Chagas disease cardiomyopathy.
Ebi3 Prevents Trypanosoma cruzi-Induced Myocarditis by Dampening IFN-γ-Driven Inflammation
Medina, Tiago Silva; Oliveira, Gabriela Gonçalves; Silva, Maria Cláudia; David, Bruna Araújo; Silva, Grace Kelly; Fonseca, Denise Morais; Sesti-Costa, Renata; Frade, Amanda Farage; Baron, Monique Andrade; Ianni, Barbara; Pereira, Alexandre Costa; Chevillard, Christophe; Cunha-Neto, Edécio; Marin-Neto, José Antonio; Silva, João Santana
2017-01-01
The identification of anti-inflammatory mediators can reveal important targetable molecules capable of counterbalancing Trypanosoma cruzi-induced myocarditis. Composed of Ebi3 and IL-27p28 subunits, IL-27 is produced by myeloid cells and is able to suppress inflammation by inducing IL-10-producing Tr1 cells, thus emerging as a potential candidate to ameliorate cardiac inflammation induced by T. cruzi. Although IL-27 has been extensively characterized as a suppressive cytokine that prevents liver immunopathogenesis after T. cruzi infection, the mechanisms underlying its effects on T. cruzi-induced myocarditis remain largely unknown. Here, wild-type (WT) and Ebi3-deficient animals were intraperitoneally infected with trypomastigotes of T. cruzi Y strain and used to evaluate the potential anti-inflammatory properties of Ebi3 during T. cruzi infection. The survival rates of mice were daily recorded, the frequency of inflammatory cells was analyzed by flow cytometry and inflammatory mediators were measured by ELISA, real-time PCR and PCR array. We reported that T. cruzi-induced myocarditis was prevented by Ebi3. Stressors mainly recognized by TLR2 and TLR4 receptors on myeloid cells were essential to trigger IL-27p28 production. In addition, Ebi3 regulated IFN-γ-mediated myocarditis by promoting an anti-inflammatory environment through IL-10, which was most likely produced by Tr1 cells rather than classical regulatory T cells (Tregs), in the heart tissue of T. cruzi-infected animals. Furthermore, in vivo IFN-γ blockade ameliorated the host survival without compromising the parasite control in the bloodstream. In humans, IL-27p28 was correlated with cardiac protection during Chagas disease. Patients with mild clinical forms of the disease produced high levels of IL-27p28, whereas lower levels were found in those with severe forms. In addition, polymorphic sites at Ebi3 gene were associated with severe cardiomyopathy in patients with Chagas disease. Collectively, we describe a novel regulatory mechanism where Ebi3 dampens cardiac inflammation by modulating the overproduction of IFN-γ, the bona fide culprit of Chagas disease cardiomyopathy. PMID:29033934
Pseudo-single-bunch mode for a 100 MHz storage ring serving soft X-ray timing experiments
NASA Astrophysics Data System (ADS)
Olsson, T.; Leemann, S. C.; Georgiev, G.; Paraskaki, G.
2018-06-01
At many storage rings for synchrotron light production there is demand for serving both high-flux and timing users simultaneously. Today this is most commonly achieved by operating inhomogeneous fill patterns, but this is not preferable for rings that employ passive harmonic cavities to damp instabilities and increase Touschek lifetime. For these rings, inhomogeneous fill patterns could severely reduce the effect of the harmonic cavities. It is therefore of interest to develop methods to serve high-flux and timing users simultaneously without requiring gaps in the fill pattern. One such method is pseudo-single-bunch (PSB), where one bunch in the bunch train is kicked onto another orbit by a fast stripline kicker. The light emitted from the kicked bunch can then be separated by an aperture in the beamline. Due to recent developments in fast kicker design, PSB operation in multibunch mode is within reach for rings that operate with a 100 MHz RF system, such as the MAX IV and Solaris storage rings. This paper describes machine requirements and resulting performance for such a mode at the MAX IV 1.5 GeV storage ring. A solution for serving all beamlines is discussed as well as the consequences of beamline design and operation in the soft X-ray energy range.
The new NHGRI-EBI Catalog of published genome-wide association studies (GWAS Catalog).
MacArthur, Jacqueline; Bowler, Emily; Cerezo, Maria; Gil, Laurent; Hall, Peggy; Hastings, Emma; Junkins, Heather; McMahon, Aoife; Milano, Annalisa; Morales, Joannella; Pendlington, Zoe May; Welter, Danielle; Burdett, Tony; Hindorff, Lucia; Flicek, Paul; Cunningham, Fiona; Parkinson, Helen
2017-01-04
The NHGRI-EBI GWAS Catalog has provided data from published genome-wide association studies since 2008. In 2015, the database was redesigned and relocated to EMBL-EBI. The new infrastructure includes a new graphical user interface (www.ebi.ac.uk/gwas/), ontology supported search functionality and an improved curation interface. These developments have improved the data release frequency by increasing automation of curation and providing scaling improvements. The range of available Catalog data has also been extended with structured ancestry and recruitment information added for all studies. The infrastructure improvements also support scaling for larger arrays, exome and sequencing studies, allowing the Catalog to adapt to the needs of evolving study design, genotyping technologies and user needs in the future. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.
Adams, Swann Arp; Rohweder, Catherine L; Leeman, Jennifer; Friedman, Daniela B; Gizlice, Ziya; Vanderpool, Robin C; Askelson, Natoshia; Best, Alicia; Flocke, Susan A; Glanz, Karen; Ko, Linda K; Kegler, Michelle
2018-05-16
While colorectal cancer (CRC) screening rates have been increasing in the general population, rates are considerably lower in Federally Qualified Health Centers (FQHCs), which serve a large proportion of uninsured and medically vulnerable patients. Efforts to screen eligible patients must be accelerated if we are to reach the national screening goal of 80% by 2018 and beyond. To inform this work, we conducted a survey of key informants at FQHCs in eight states to determine which evidence-based interventions (EBIs) to promote CRC screening are currently being used, and which implementation strategies are being employed to ensure that the interventions are executed as intended. One hundred and forty-eight FQHCs were invited to participate in the study, and 56 completed surveys were received for a response rate of 38%. Results demonstrated that provider reminder and recall systems were the most commonly used EBIs (44.6%) while the most commonly used implementation strategy was the identification of barriers (84.0%). The mean number of EBIs that were fully implemented at the centers was 2.4 (range 0-7) out of seven. Almost one-quarter of respondents indicated that their FQHCs were not using any EBIs to increase CRC screening. Full implementation of EBIs was correlated with higher CRC screening rates. These findings identify gaps as well as the preferences and needs of FQHCs in selecting and implementing EBIs for CRC screening.
Comparison of dry-textile electrodes for electrical bioimpedance spectroscopy measurements
NASA Astrophysics Data System (ADS)
Márquez, J. C.; Seoane, F.; Välimäki, E.; Lindecrantz, K.
2010-04-01
Textile Electrodes have been widely studied for biopotentials recordings, specially for monitoring the cardiac activity. Commercially available applications, such as Adistar T-shirt and Textronics Cardioshirt, have proved a good performance for heart rate monitoring and are available worldwide. Textile technology can also be used for Electrical Bioimpedance Spectroscopy measurements enabling home and personalized health monitoring applications however solid ground research about the measurement performance of the electrodes must be done prior to the development of any textile-enabled EBI application. In this work a comparison of the measurement performance of two different types of dry-textile electrodes and manufacturers has been performed against standardized RedDot 3M Ag/AgCl electrolytic electrodes. 4-Electrode, whole body, Ankle-to-Wrist EBI measurements have been taken with the Impedimed spectrometer SFB7 from healthy subjects in the frequency range of 3kHz to 500kHz. Measurements have been taken with dry electrodes at different times to study the influence of the interaction skin-electrode interface on the EBI measurements. The analysis of the obtained complex EBI spectra shows that the measurements performed with textile electrodes produce constant and reliable EBI spectra. Certain deviation can be observed at higher frequencies and the measurements obtained with Textronics and Ag/AgCl electrodes present a better resemblance. Textile technology, if successfully integrated it, may enable the performance of EBI measurements in new scenarios allowing the rising of novel wearable monitoring applications for home and personal care as well as car safety.
A Model Describing Stable Coherent Synchrotron Radiation in Storage Rings
NASA Astrophysics Data System (ADS)
Sannibale, F.; Byrd, J. M.; Loftsdóttir, Á.; Venturini, M.; Abo-Bakr, M.; Feikes, J.; Holldack, K.; Kuske, P.; Wüstefeld, G.; Hübers, H.-W.; Warnock, R.
2004-08-01
We present a model describing high power stable broadband coherent synchrotron radiation (CSR) in the terahertz frequency region in an electron storage ring. The model includes distortion of bunch shape from the synchrotron radiation (SR), which enhances higher frequency coherent emission, and limits to stable emission due to an instability excited by the SR wakefield. It gives a quantitative explanation of several features of the recent observations of CSR at the BESSYII storage ring. We also use this model to optimize the performance of a source for stable CSR emission.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-06-01
Proposed action is to construct at BNL a 5,600-ft[sup 2] support building, install and operate a prototypic 200 MeV accelerator and a prototypic 700 MeV storage ring within, and to construct and operate a 15 kV substation to power the building. The accelerator and storage ring would comprise the x-ray lithography source or XLS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-06-01
Proposed action is to construct at BNL a 5,600-ft{sup 2} support building, install and operate a prototypic 200 MeV accelerator and a prototypic 700 MeV storage ring within, and to construct and operate a 15 kV substation to power the building. The accelerator and storage ring would comprise the x-ray lithography source or XLS.
High resolution monochromator for the VUV radiation from the DORIS storage ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saile, V.; Gurtler, P.; Koch, E.E.
1976-10-01
The unique properties of the DORIS storage ring at DESY as a synchroton radiation source are exploited for high resolution spectroscopy in the vacuum ultraviolet. We describe a new experimental set up with a 3-m normal incidence monochromator for wavelengths between 3000 A and 300 A (4 < or = h..omega.. < or = 40 eV) using a vertical dispersion plane. The storage ring provides a light flux intense and stable enough for rapid photoelectrical scanning of the spectra with a resolution of 0.03 A in first order. (AIP)
Design Study of an MBA Lattice for the Advanced Photon Source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Decker, Glenn
2014-11-02
Recent interest in ultra-low-emittance designs for storage-ring-based synchrotron light sources has spurred a focused design effort on a multi-bend achromat (MBA) storage ring replacement for the Advanced Photon Source (APS). The APS is relatively large (1104 m circumference) and, as such, an upgrade to a fourth-generation storage ring holds the potential for a two to three order of magnitude enhancement of X-ray brightness due to the approximate inverse cubic scaling of emittance with the number of dipole bend magnets.
ACCELERATORS: Preliminary application of turn-by-turn data analysis to the SSRF storage ring
NASA Astrophysics Data System (ADS)
Chen, Jian-Hui; Zhao, Zhen-Tang
2009-07-01
There is growing interest in utilizing the beam position monitor turn-by-turn (TBT) data to debug accelerators. TBT data can be used to determine the linear optics, coupled optics and nonlinear behaviors of the storage ring lattice. This is not only a useful complement to other methods of determining the linear optics such as LOCO, but also provides a possibility to uncover more hidden phenomena. In this paper, a preliminary application of a β function measurement to the SSRF storage ring is presented.
Guidoboni, G.; Stephenson, E.; Andrianov, S.; ...
2016-07-28
Here, we observe a deuteron beam polarization lifetime near 1000 s in the horizontal plane of a magnetic storage ring (COSY). This long spin coherence time is maintained through a combination of beam bunching, electron cooling, sextupole field corrections, and the suppression of collective effects through beam current limits. This record lifetime is required for a storage ring search for an intrinsic electric dipole moment on the deuteron at a statistical sensitivity level approaching 10 -29 $e$ cm.
easyDAS: Automatic creation of DAS servers
2011-01-01
Background The Distributed Annotation System (DAS) has proven to be a successful way to publish and share biological data. Although there are more than 750 active registered servers from around 50 organizations, setting up a DAS server comprises a fair amount of work, making it difficult for many research groups to share their biological annotations. Given the clear advantage that the generalized sharing of relevant biological data is for the research community it would be desirable to facilitate the sharing process. Results Here we present easyDAS, a web-based system enabling anyone to publish biological annotations with just some clicks. The system, available at http://www.ebi.ac.uk/panda-srv/easydas is capable of reading different standard data file formats, process the data and create a new publicly available DAS source in a completely automated way. The created sources are hosted on the EBI systems and can take advantage of its high storage capacity and network connection, freeing the data provider from any network management work. easyDAS is an open source project under the GNU LGPL license. Conclusions easyDAS is an automated DAS source creation system which can help many researchers in sharing their biological data, potentially increasing the amount of relevant biological data available to the scientific community. PMID:21244646
BiNChE: a web tool and library for chemical enrichment analysis based on the ChEBI ontology.
Moreno, Pablo; Beisken, Stephan; Harsha, Bhavana; Muthukrishnan, Venkatesh; Tudose, Ilinca; Dekker, Adriano; Dornfeldt, Stefanie; Taruttis, Franziska; Grosse, Ivo; Hastings, Janna; Neumann, Steffen; Steinbeck, Christoph
2015-02-21
Ontology-based enrichment analysis aids in the interpretation and understanding of large-scale biological data. Ontologies are hierarchies of biologically relevant groupings. Using ontology annotations, which link ontology classes to biological entities, enrichment analysis methods assess whether there is a significant over or under representation of entities for ontology classes. While many tools exist that run enrichment analysis for protein sets annotated with the Gene Ontology, there are only a few that can be used for small molecules enrichment analysis. We describe BiNChE, an enrichment analysis tool for small molecules based on the ChEBI Ontology. BiNChE displays an interactive graph that can be exported as a high-resolution image or in network formats. The tool provides plain, weighted and fragment analysis based on either the ChEBI Role Ontology or the ChEBI Structural Ontology. BiNChE aids in the exploration of large sets of small molecules produced within Metabolomics or other Systems Biology research contexts. The open-source tool provides easy and highly interactive web access to enrichment analysis with the ChEBI ontology tool and is additionally available as a standalone library.
Characterization of pitch prepared from pyrolysis fuel oil via electron beam irradiation
NASA Astrophysics Data System (ADS)
Kim, Hong Gun; Park, Mira; Kim, Hak-Yong; Kwac, Lee Ku; Shin, Hye Kyoung
2017-06-01
Pitch samples were obtained from pyrolysis fuel oil by thermal treatment for 2 h at 300 °C after electron beam irradiation (EBI) treatment and by thermal treatment alone for different temperature of 250 °C, 300 °C, and 350 °C. EBI treatment was found to be an effective treatment for preparing pitch compare to the pitch obtained without EBI treatment. These results were confirmed by Fourier transform infrared spectroscopy (FT-IR) and Carbon-13 nuclear magnetic resonance (13C NMR) analyses, which showed the increase in the intensities of peaks corresponding to aromatic compounds. In the matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) spectra, the amount of components with medium molecular weights in the pitch was found to increase with the temperature; likewise, in the case of the pitch obtained via EBI treatment, we found that the amount of components with higher molecular weight over 1000 (m/v) similarly increased. Further, the thermal stability and carbon yield at 850 °C of the pitch obtained by EBI were greater than those of samples subjected to thermal treatment at 250 and 300 °C.
NASA Astrophysics Data System (ADS)
Balleza, M.; Vargas, M.; Kashina, S.; Huerta, M. R.; Delgadillo, I.; Moreno, G.
2017-01-01
Several research groups have proposed the electrical impedance tomography (EIT) in order to analyse lung ventilation. With the use of 16 electrodes, the EIT is capable to obtain a set of transversal section images of thorax. In previous works, we have obtained an alternating signal in terms of impedance corresponding to respiration from EIT images. Then, in order to transform those impedance changes into a measurable volume signal a set of calibration equations has been obtained. However, EIT technique is still expensive to attend outpatients in basics hospitals. For that reason, we propose the use of electrical bioimpedance (EBI) technique to monitor respiration behaviour. The aim of this study was to obtain a set of calibration equations to transform EBI impedance changes determined at 4 different frequencies into a measurable volume signal. In this study a group of 8 healthy males was assessed. From obtained results, a high mathematical adjustment in the group calibrations equations was evidenced. Then, the volume determinations obtained by EBI were compared with those obtained by our gold standard. Therefore, despite EBI does not provide a complete information about impedance vectors of lung compared with EIT, it is possible to monitor the respiration.
Dielectronic recombination experiments at the storage rings: From the present CSR to the future HIAF
NASA Astrophysics Data System (ADS)
Huang, Z. K.; Wen, W. Q.; Xu, X.; Wang, H. B.; Dou, L. J.; Chuai, X. Y.; Zhu, X. L.; Zhao, D. M.; Li, J.; Ma, X. M.; Mao, L. J.; Yang, J. C.; Yuan, Y. J.; Xu, W. Q.; Xie, L. Y.; Xu, T. H.; Yao, K.; Dong, C. Z.; Zhu, L. F.; Ma, X.
2017-10-01
Dielectronic recombination (DR) experiments of highly charged ions at the storage rings have been developed as a precision spectroscopic tool to investigate the atomic structure as well as nuclear properties of stable and unstable nuclei. The DR experiment on lithium-like argon ions was successfully performed at main Cooler Storage Ring (CSRm) at Heavy Ion Research Facility in Lanzhou (HIRFL) accelerator complex. The DR experiments on heavy highly charged ions and even radioactive ions are currently under preparation at the experimental Cooler Storage Ring (CSRe) at HIRFL. The current status of DR experiments at the CSRm and the preparation of the DR experiments at the CSRe are presented. In addition, an overview of DR experiments by employing an electron cooler and a separated ultra-cold electron target at the upcoming High Intensity heavy ion Accelerator Facility (HIAF) will be given.
Bruno Touschek: From Betatrons to Electron-Positron Colliders
NASA Astrophysics Data System (ADS)
Bernardini, Carlo; Pancheri, Giulia; Pellegrini, Claudio
Bruno Touschek's life as a physicist spanned the period from World War II to the 1970s. He was a key figure in the developments of electron-positron colliders and storage rings, and made important contributions to theoretical high energy physics. Storage rings, initially developed for high energy physics, are being widely used in many countries as synchrotron radiation sources and are a tool for research in physics, chemistry, biology, environmental sciences and cultural heritage studies. We describe Touschek's life in Austria, where he was born, in Germany, where he participated in the construction of a betatron during WWII, and in Italy, where he proposed and led to completion the first electron-positron storage ring in 1960, in Frascati. We highlight how his central European culture influenced his lifestyle and work, and his main contributions to physics, such as the discovery of the Touschek effect and beam instabilities in the larger storage ring ADONE.
Bruno Touschek: From Betatrons to Electron-Positron Colliders
NASA Astrophysics Data System (ADS)
Bernardini, Carlo; Pancheri, Giulia; Pellegrini, Claudio
Bruno Touschek’s life as a physicist spanned the period from World War II to the 1970s. He was a key figure in the developments of electron-positron colliders and storage rings, and made important contributions to theoretical high energy physics. Storage rings, initially developed for high energy physics, are being widely used in many countries as synchrotron radiation sources and are a tool for research in physics, chemistry, biology, environmental sciences and cultural heritage studies. We describe Touschek’s life in Austria, where he was born, in Germany, where he participated in the construction of a betatron during WWII, and in Italy, where he proposed and led to completion the first electron-positron storage ring in 1960, in Frascati. We highlight how his central European culture influenced his lifestyle and work, and his main contributions to physics, such as the discovery of the Touschek effect and beam instabilities in the larger storage ring ADONE.
High-energy accelerator for beams of heavy ions
Martin, Ronald L.; Arnold, Richard C.
1978-01-01
An apparatus for accelerating heavy ions to high energies and directing the accelerated ions at a target comprises a source of singly ionized heavy ions of an element or compound of greater than 100 atomic mass units, means for accelerating the heavy ions, a storage ring for accumulating the accelerated heavy ions and switching means for switching the heavy ions from the storage ring to strike a target substantially simultaneously from a plurality of directions. In a particular embodiment the heavy ion that is accelerated is singly ionized hydrogen iodide. After acceleration, if the beam is of molecular ions, the ions are dissociated to leave an accelerated singly ionized atomic ion in a beam. Extraction of the beam may be accomplished by stripping all the electrons from the atomic ion to switch the beam from the storage ring by bending it in magnetic field of the storage ring.
Injection envelope matching in storage rings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Minty, M.G.; Spence, W.L.
1995-05-01
The shape and size of the transverse phase space injected into a storage ring can be deduced from turn-by-turn measurements of the transient behavior of the beam envelope in the ring. Envelope oscillations at 2 x the {beta}-tron frequency indicate the presence of a {beta}-mismatch, while envelope oscillations at the {beta}-tron frequency are the signature of a dispersion function mismatch. Experiments in injection optimization using synchrotron radiation imaging of the beam and a fast-gated camera at the SLC damping rings are reported.
Injection envelope matching in storage rings
NASA Astrophysics Data System (ADS)
Minty, M. G.; Spence, W. L.
1995-05-01
The shape and size of the transverse phase space injected into a storage ring can be deduced from turn-by-turn measurements of the transient behavior of the beam envelope in the ring. Envelope oscillations at 2 x the beta-tron frequency indicate the presence of a beta-mismatch, while envelope oscillations at the beta-tron frequency are the signature of a dispersion function mismatch. Experiments in injection optimization using synchrotron radiation imaging of the beam and a fast-gated camera at the SLC damping rings are reported.
Searching and Extracting Data from the EMBL-EBI Complex Portal.
Meldal, Birgit H M; Orchard, Sandra
2018-01-01
The Complex Portal ( www.ebi.ac.uk/complexportal ) is an encyclopedia of macromolecular complexes. Complexes are assigned unique, stable IDs, are species specific, and list all participating members with links to an appropriate reference database (UniProtKB, ChEBI, RNAcentral). Each complex is annotated extensively with its functions, properties, structure, stoichiometry, tissue expression profile, and subcellular location. Links to domain-specific databases allow the user to access additional information and enable data searching and filtering. Complexes can be saved and downloaded in PSI-MI XML, MI-JSON, and tab-delimited formats.
First charge breeding results at CARIBU EBIS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kondrashev, S., E-mail: kondrashev@anl.gov; Barcikowski, A., E-mail: kondrashev@anl.gov; Dickerson, C., E-mail: kondrashev@anl.gov
The Electron Beam Ion Source (EBIS) developed to breed CARIBU radioactive beams at ATLAS is currently in the off-line commissioning stage. The beam commissioning is being performed using a low emittance surface ionization source producing singly-charged cesium ions. The primary goal of the off-line commissioning is the demonstration of high-efficiency charge breeding in the pulsed injection mode. An overview of the final design of the CARIBU EBIS charge breeder, the off-line commissioning installation and the first results on charge breeding of stable cesium ions are presented and discussed.
San-Juan, Rafael; Aguado, Jose M; Lumbreras, Carlos; Fortun, Jesus; Len, Oscar; Munoz, Patricia; Montejo, Miguel; Moreno, Asunción; Cordero, Elisa; Blanes, Marino; Ramos, Antonio; Torre-Cisneros, Julian; López-Medrano, Francisco; Carratala, Jordi; Moreno, Enrique
2011-08-01
The role of selective intestinal decontamination with fluoroquinolones (FQ-SID) in the prevention of early bacterial infections (EBIs) in liver transplant recipients (LTRs) is unknown. We used the online database of the Spanish Network of Infection in Transplantation/Spanish Network for Research in Infectious Diseases, which prospectively analyzed 1010 LTRs from 12 Spanish hospitals from September 2003 to February 2005. We compared the incidence and etiology of EBIs (30 days after transplantation) in 415 LTRs from 4 centers that used FQ-SID (>7 days) and in 595 LTRs from 8 hospitals that did not use FQ-SID. A multivariate logistic regression analysis (including an adjustment for the transplant center factor) was performed to evaluate the potential protective factor of FQ-SID in the development of EBIs. We reported 266 EBI episodes in 252 LTRs (incidence = 24.9%). There were no differences in the incidence of EBIs between patients in the FQ-SID group and patients not in the FQ-SID group [109/415 (26.3%) versus 143/595 (24%), P = 0.9]. Although LTRs who received FQ-SID had a lower incidence of infections due to enteric bacteria (2.7% versus 6.5%, P = 0.007) and a higher incidence of infections due to nonfermenting gram-negative bacilli (6.6% versus 2.6%, P = 0.004), these findings could not be confirmed after an adjustment by the center factor in the multivariate models. We found no significant differences in the incidence of enterococcal infections (3.4% with FQ-SID versus 3.9% without FQ-SID, P = 0.5). Multivariate analysis did not confirm any protective effect of FQ-SID against the development of EBIs by enteric bacteria. In conclusion, FQ-SID does not reduce the incidence of EBIs in LTRs and could be withheld from this group of patients. Copyright © 2011 American Association for the Study of Liver Diseases.
Issues and Challenges in the Design of Culturally Adapted Evidence-Based Interventions
Castro, Felipe González; Barrera, Manuel; Holleran Steiker, Lori K.
2014-01-01
This article examines issues and challenges in the design of cultural adaptations that are developed from an original evidence-based intervention (EBI). Recently emerging multistep frameworks or stage models are examined, as these can systematically guide the development of culturally adapted EBIs. Critical issues are also presented regarding whether and how such adaptations may be conducted, and empirical evidence is presented regarding the effectiveness of such cultural adaptations. Recent evidence suggests that these cultural adaptations are effective when applied with certain subcultural groups, although they are less effective when applied with other subcultural groups. Generally, current evidence regarding the effectiveness of cultural adaptations is promising but mixed. Further research is needed to obtain more definitive conclusions regarding the efficacy and effectiveness of culturally adapted EBIs. Directions for future research and recommendations are presented to guide the development of a new generation of culturally adapted EBIs. PMID:20192800
Status and outlook of the CRYRING@ESR project
NASA Astrophysics Data System (ADS)
Geithner, W.; Andelkovic, Z.; Beck, D.; Bräuning, H.; Bräuning-Demian, A.; Danared, H.; Dimopoulou, C.; Engström, M.; Fedotova, S.; Gorda, O.; Herfurth, F.; Hess, R.; Källberg, A.; Kleffner, C.; Kotovskiy, N.; Kraus, I.; Lestinsky, M.; Litvinov, S.; Nolden, F.; Reiter, A.; Sieber, T.; Steck, M.; Vorobyev, G.
2017-11-01
Once operational, CRYRING@ESR will store and decelerate ions delivered by the experimental storage ring ESR at energies well below those of ESR. In addition to that, CRYRING@ESR has an electron cooler operating with an ultracold electron beam, allowing to provide cooled ion beams for precision experiments. These ions will be delivered to a broad range of experiments presently in preparation; either in-ring or extracted to a dedicated beamline for experiments. An overview and status report of the installation and commissioning of the CRYRING-@ESR storage ring for highly charged ions at the GSI Helmholtzzentrum für Schwerionenforschung is presented. The installation of this storage ring started in 2014 and was completing end of 2016, when this publication was written.
Status of the Frankfurt low energy electrostatic storage ring (FLSR)
NASA Astrophysics Data System (ADS)
King, F.; Kruppi, T.; Müller, J.; Dörner, R.; Schmidt, L. Ph H.; Schmidt-Böcking, H.; Stiebing, K. E.
2015-11-01
Frankfurt low-energy storage ring (FLSR) is an electrostatic storage ring for low-energy ions up to q · 80 keV (q being the ion charge state) at Institut für Kernphysik der Goethe-Universität, Frankfurt am Main, Germany. It has especially been designed to provide a basis for experiments on the dynamics of ionic and molecular collisions in complete kinematics, as well as for high precision and time resolved laser spectroscopy. The ring has ‘racetrack’ geometry with a circumference of 14.23 m. It comprises four experimental/diagnostic sections with regions of enhanced ion density (interaction regions). First beam has successfully been stored in FLSR in summer 2013. Since then the performance of the ring has continuously been improved and an electron target for experiments on dissociative recombination has been installed in one of the experimental sections.
Update and expansion of the HIV/AIDS prevention program archive (HAPPA)
Card, Josefina J.; Cunningham, Shayna D.; Newman, Emily N.; Golden, Rachel E.
2017-01-01
Established in 1996 with funding from CDC and NIH, the HIV/AIDS Prevention Program Archive (HAPPA) is now the biggest private sector collection of HIV-related evidence-based behavioral interventions (EBIs). Each EBI in HAPPA has been determined by a distinguished Scientist Expert Panel to have demonstrated efficacy in preventing HIV or its risk-related behaviors in the United States. The multimedia replications kits contain everything that a new site would need to implement an EBI such as a user guide that gives an overview of the program and the evidence of its effectiveness; a facilitator’s manual that gives step-by-step implementation protocols for each session; and session implementation materials referenced in the facilitator's manual such as slides, video clips, participant handouts, activity masters, checklists, and homework assignments for the next session. The program packages also contain evaluation materials such as surveys and questionnaires that were used in the original demonstration of effectiveness and that may be used to re-evaluate the program as implemented in a new setting. Recently, we have expanded HAPPA’s scope to include HIV EBIs developed globally and to include evidence-based structural interventions (effective in modifying the physical, social, cultural, political, economic, legal, and/or policy aspects of the HIV risk environment). This paper describes HAPPA’s procedures for identifying, selecting, acquiring and packaging HIV EBIs. It also provides comprehensive lists of evidence-based HIV behavioral and structural interventions and gives information on how to access EBI program packages for implementation in new settings. PMID:28781971
NASA Astrophysics Data System (ADS)
Husain, Riyasat; Ghodke, A. D.
2017-08-01
Estimation and correction of the optics errors in an operational storage ring is always vital to achieve the design performance. To achieve this task, the most suitable and widely used technique, called linear optics from closed orbit (LOCO) is used in almost all storage ring based synchrotron radiation sources. In this technique, based on the response matrix fit, errors in the quadrupole strengths, beam position monitor (BPM) gains, orbit corrector calibration factors etc. can be obtained. For correction of the optics, suitable changes in the quadrupole strengths can be applied through the driving currents of the quadrupole power supplies to achieve the desired optics. The LOCO code has been used at the Indus-2 storage ring for the first time. The estimation of linear beam optics errors and their correction to minimize the distortion of linear beam dynamical parameters by using the installed number of quadrupole power supplies is discussed. After the optics correction, the performance of the storage ring is improved in terms of better beam injection/accumulation, reduced beam loss during energy ramping, and improvement in beam lifetime. It is also useful in controlling the leakage in the orbit bump required for machine studies or for commissioning of new beamlines.
Low emittance electron storage rings
NASA Astrophysics Data System (ADS)
Levichev, E. B.
2018-01-01
Low-emittance electron (positron) beams are essential for synchrotron light sources, linear collider damping rings, and circular Crab Waist colliders. In this review, the principles and methods of emittance minimization are discussed, prospects for developing relativistic electron storage rings with small beam phase volume are assessed, and problems related to emittance minimization are examined together with their possible solutions. The special features and engineering implementation aspects of various facilities are briefly reviewed.
Hastings, Janna; de Matos, Paula; Dekker, Adriano; Ennis, Marcus; Harsha, Bhavana; Kale, Namrata; Muthukrishnan, Venkatesh; Owen, Gareth; Turner, Steve; Williams, Mark; Steinbeck, Christoph
2013-01-01
ChEBI (http://www.ebi.ac.uk/chebi) is a database and ontology of chemical entities of biological interest. Over the past few years, ChEBI has continued to grow steadily in content, and has added several new features. In addition to incorporating all user-requested compounds, our annotation efforts have emphasized immunology, natural products and metabolites in many species. All database entries are now 'is_a' classified within the ontology, meaning that all of the chemicals are available to semantic reasoning tools that harness the classification hierarchy. We have completely aligned the ontology with the Open Biomedical Ontologies (OBO) Foundry-recommended upper level Basic Formal Ontology. Furthermore, we have aligned our chemical classification with the classification of chemical-involving processes in the Gene Ontology (GO), and as a result of this effort, the majority of chemical-involving processes in GO are now defined in terms of the ChEBI entities that participate in them. This effort necessitated incorporating many additional biologically relevant compounds. We have incorporated additional data types including reference citations, and the species and component for metabolites. Finally, our website and web services have had several enhancements, most notably the provision of a dynamic new interactive graph-based ontology visualization.
Design of an EBIS charge breeder system for rare-isotope beams
NASA Astrophysics Data System (ADS)
Park, Young-Ho; Son, Hyock-Jun; Kim, Jongwon
2016-09-01
Rare-isotope beams will be produced by using the isotope separation on-line (ISOL) system at the Rare Isotope Science Project (RISP). A proton cyclotron is the driver accelerator for ISOL targets, and uranium carbide (UCx) will be a major target material. An isotope beam of interest extracted from the target will be ionized and selected by using a mass separator. The beam emittance will then be reduced by using a radio-frequency quadrupole (RFQ) cooler before the beam is injected into the electron-beam ion-source (EBIS) charge breeder (CB). The maximum electron beam current of the EBIS is 3 A from a cathode made of IrCe in an applied magnetic field of 0.2 T. The size of the electron beam is compressed by magnetic fields of up to 6 T caused in the charge-breeding region by a superconducting solenoid. The design of EBIS-CB was performed by using mechanics as well as beam optics. A test stand for the electron gun and its collector, which can take an electron-beam power of 20 kW, are under construction. The gun assembly was first tested by using a high-voltage pulse so as to measure its perveance. The design of the EBIS, along with its test stand, is described.
Picosecond, tunable, high-brightness hard x-ray inverse Compton source at Duke storage ring
NASA Astrophysics Data System (ADS)
Litvinenko, Vladimir N.; Wu, Ying; Burnham, Bentley; Barnett, Genevieve A.; Madey, John M. J.
1995-09-01
We suggest a state-of-the art x-ray source using a compact electron storage ring with modest energy (less than 1 GeV) and a high power mm-wave as an undulator. A source of this type has x-ray energies and brightness comparable with third generation synchrotron light sources while it can be very compact and fit in a small university or industrial laboratory or hospital. We propose to operate an isochronous mm-wave FEL and a hard x-ray inverse Compton source at the Duke storage ring to test this concept. Resonant FEL conditions for the mm- wave will be provided by the off-axis interaction with an electromagnetic wave. A special optical resonator with holes for the e-beam is proposed for pumping a hard x-ray inverse Compton source with very high brightness. Simulation results of mm-wave FEL operation of the Duke storage ring are discussed. Expected performance of mm-wave FEL and hard x-ray inverse Compton source are presented.
The Storage Ring Proton EDM Experiment
NASA Astrophysics Data System (ADS)
Semertzidis, Yannis; Storage Ring Proton EDM Collaboration
2014-09-01
The storage ring pEDM experiment utilizes an all-electric storage ring to store ~1011 longitudinally polarized protons simultaneously in clock-wise and counter-clock-wise directions for 103 seconds. The radial E-field acts on the proton EDM for the duration of the storage time to precess its spin in the vertical plane. The ring lattice is optimized to reduce intra-beam scattering, increase the statistical sensitivity and reduce the systematic errors of the method. The main systematic error is a net radial B-field integrated around the ring causing an EDM-like vertical spin precession. The counter-rotating beams sense this integrated field and are vertically shifted by an amount, which depends on the strength of the vertical focusing in the ring, thus creating a radial B-field. Modulating the vertical focusing at 10 kHz makes possible the detection of this radial B-field by a SQUID-magnetometer (SQUID-based BPM). For a total number of n SQUID-based BPMs distributed around the ring the effectiveness of the method is limited to the N = n /2 harmonic of the background radial B-field due to the Nyquist sampling theorem limit. This limitation establishes the requirement to reduce the maximum radial B-field to 0.1-1 nT everywhere around the ring by layers of mu-metal and aluminum vacuum tube. The metho's sensitivity is 10-29 e .cm , more than three orders of magnitude better than the present neutron EDM experimental limit, making it sensitive to SUSY-like new physics mass scale up to 300 TeV.
Aarons, Gregory A; Green, Amy E; Trott, Elise; Willging, Cathleen E; Torres, Elisa M; Ehrhart, Mark G; Roesch, Scott C
2016-11-01
If evidence-based interventions (EBIs) are not sustained, investments are wasted and public health impact is limited. Leadership has been suggested as a key determinant of implementation and sustainment; however, little empirical work has examined this factor. This mixed-methods study framed using the Exploration, Preparation, Implementation, Sustainment (EPIS) conceptual framework examines leadership in both the outer service system context and inner organizational context in eleven system-wide implementations of the same EBI across two U.S. states and 87 counties. Quantitative data at the outer context (i.e., system) and inner context (i.e., team) levels demonstrated that leadership predicted future sustainment and differentiated between sites with full, partial, or no sustainment. In the outer context positive sustainment leadership was characterized as establishing a project's mission and vision, early and continued planning for sustainment, realistic project plans, and having alternative strategies for project survival. Inner context frontline transformational leadership predicted sustainment while passive-avoidant leadership predicted non-sustainment. Qualitative results found that sustainment was associated with outer context leadership characterized by engagement in ongoing supportive EBI championing, marketing to stakeholders; persevering in these activities; taking action to institutionalize the EBI with funding, contracting, and system improvement plans; and fostering ongoing collaboration between stakeholders at state and county, and community stakeholder levels. For frontline leadership the most important activities included championing the EBI and providing practical support for service providers. There was both convergence and expansion that identified unique contributions of the quantitative and qualitative methods. Greater attention to leadership in both the outer system and inner organizational contexts is warranted to enhance EBI implementation and sustainment.
Aarons, Gregory A.; Green, Amy E.; Trott, Elise; Willging, Cathleen E.; Torres, Elisa M.; Ehrhart, Mark G.; Roesch, Scott C.
2017-01-01
If evidence-based interventions (EBIs) are not sustained, investments are wasted and public health impact is limited. Leadership has been suggested as a key determinant of implementation and sustainment; however, little empirical work has examined this factor. This mixed-methods study framed using the Exploration, Preparation, Implementation, Sustainment (EPIS) conceptual framework examines leadership in both the outer service system context and inner organizational context in eleven system-wide implementations of the same EBI across two U.S. states and 87 counties. Quantitative data at the outer context (i.e., system) and inner context (i.e., team) levels demonstrated that leadership predicted future sustainment and differentiated between sites with full, partial, or no sustainment. In the outer context positive sustainment leadership was characterized as establishing a project’s mission and vision, early and continued planning for sustainment, realistic project plans, and having alternative strategies for project survival. Inner context frontline transformational leadership predicted sustainment while passive-avoidant leadership predicted non-sustainment. Qualitative results found that sustainment was associated with outer context leadership characterized by engagement in ongoing supportive EBI championing, marketing to stakeholders; persevering in these activities; taking action to institutionalize the EBI with funding, contracting, and system improvement plans; and fostering ongoing collaboration between stakeholders at state and county, and community stakeholder levels. For frontline leadership the most important activities included championing the EBI and providing practical support for service providers. There was both convergence and expansion that identified unique contributions of the quantitative and qualitative methods. Greater attention to leadership in both the outer system and inner organizational contexts is warranted to enhance EBI implementation and sustainment. PMID:27439504
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zeno, Keith
2016-10-21
During Run 16 the Tandem was used as the Gold pre-injector for a brief time so that RHIC could continue running while EBIS was down for repairs. Given the time constraints, the setup was largely derived from the EBIS Au setup. The EBIS Au setup used a 4:2:1 bunch merge in the Booster and a 12:6:2 bunch merge in the AGS.1 This note will describe the Tandem Au setup and compare it to that used for EBIS Au. The bunch merge in the Booster for Tandem Au did not work well, and it seems likely that the performance would’ve beenmore » significantly better if it did. An AGS type 6:3:1 merge in the Booster is described which might improve matters.2 Somewhat speculative estimates for the AGS bunch intensity and emittance, if that merge were successful in reducing the Booster extraction emittance to EBIS Au levels, are also given for several potential setups. Using 6 Booster loads from the Tandem, the AGS bunch intensity at extraction reached about 2.5e9 ions with a longitudinal emittance (ε) of about 0.59 eV·s/n.3 Using 12 Booster loads from EBIS, the peak bunch intensity and ε was about 3.1e9 ions and 0.75 eV·s/n, respectively. A 6.4 sec supercycle was used for both at the time, but the Tandem Au supercycle (barring any potential issues with Tandem) could probably have been reduced to about 4.6 sec.« less
Dose estimates for the 1104 m APS storage ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moe, H.J.
1989-06-01
The estimated dose equivalent rates outside the shielded storage ring, and the estimated annual dose equivalent to members of the public due to direct radiation and skyshine from the ring, have been recalculated. The previous estimates found in LS-84 (MOE 87) and cited in the 1987 Conceptual Design Report of the APS (ANL 87) required revision because of changes in the ring circumference and in the proposed location of the ring with respect to the nearest site boundary. The values assumed for the neutron quality factors were also overestimated (by a factor of 2) in the previous computation, and themore » correct values have been used for this estimate. The methodology used to compute dose and dose rate from the storage ring is the same as that used in LS-90 (MOE 87a). The calculations assumed 80 cm thick walls of ordinary concrete (or the shielding equivalent of this) and a roof thickness of 1 meter of ordinary concrete. The circumference of the ring was increased to 1,104 m, and the closest distance to the boundary was taken as 140 m. The recalculation of the skyshine component used the same methodology as that used in LS-84.« less
Perspectives on micropole undulators in synchrotron radiation technology
NASA Astrophysics Data System (ADS)
Tatchyn, Roman; Csonka, Paul; Toor, Arthur
1989-07-01
Micropole undulators promise to advance synchrotron radiation (SR) technology in two distinct ways. The first is in the development of economical, low-energy storage rings, or linacs, as soft x-ray sources, and the second is in the opening up of gamma-ray spectral ranges on high-energy storage rings. In this paper the promise and current status of micropole undulator (MPU) technology are discussed, and a review of some practical obstacles to the implementation of MPU's on present-day storage rings is given. Some successful results of recent performance measurements of micropole undulators on the Lawrence Livermore National Laboratory linac are briefly summarized.
Galbraith, Jennifer S.; Stanton, Bonita; Boekeloo, Bradley; King, Winifred; Desmond, Sharon; Howard, Donna; Black, Maureen M.; Carey, James W.
2014-01-01
Evidence-based interventions (EBIs) are used in public health to prevent HIV infection among youth and other groups. EBIs include core elements, features that are thought to be responsible for the efficacy of interventions. The authors evaluate experiences of organizations that adopted an HIV-prevention EBI, Focus on Kids (FOK), and their fidelity to the intervention’s eight core elements. A cross-sectional telephone survey was administered to 34 staff members from organizations that had previously implemented FOK. Questions assessed how the organization adhered to, adapted, dropped, or altered the intervention. None of the organizations implemented all eight core elements. This study underscores the importance for HIV intervention researchers to clearly identify and describe core elements. More effort is needed to reflect the constraints practitioners face in nonresearch settings. To ensure intervention effectiveness, additional research and technical assistance are needed to help organizations implement HIV prevention EBIs with fidelity. PMID:18445739
First test of BNL electron beam ion source with high current density electron beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pikin, Alexander, E-mail: pikin@bnl.gov; Alessi, James G., E-mail: pikin@bnl.gov; Beebe, Edward N., E-mail: pikin@bnl.gov
A new electron gun with electrostatic compression has been installed at the Electron Beam Ion Source (EBIS) Test Stand at BNL. This is a collaborative effort by BNL and CERN teams with a common goal to study an EBIS with electron beam current up to 10 A, current density up to 10,000 A/cm{sup 2} and energy more than 50 keV. Intensive and pure beams of heavy highly charged ions with mass-to-charge ratio < 4.5 are requested by many heavy ion research facilities including NASA Space Radiation Laboratory (NSRL) at BNL and HIE-ISOLDE at CERN. With a multiampere electron gun, themore » EBIS should be capable of delivering highly charged ions for both RHIC facility applications at BNL and for ISOLDE experiments at CERN. Details of the electron gun simulations and design, and the Test EBIS electrostatic and magnetostatic structures with the new electron gun are presented. The experimental results of the electron beam transmission are given.« less
Data Access Based on a Guide Map of the Underwater Wireless Sensor Network
Wei, Zhengxian; Song, Min; Yin, Guisheng; Wang, Hongbin; Cheng, Albert M. K.
2017-01-01
Underwater wireless sensor networks (UWSNs) represent an area of increasing research interest, as data storage, discovery, and query of UWSNs are always challenging issues. In this paper, a data access based on a guide map (DAGM) method is proposed for UWSNs. In DAGM, the metadata describes the abstracts of data content and the storage location. The center ring is composed of nodes according to the shortest average data query path in the network in order to store the metadata, and the data guide map organizes, diffuses and synchronizes the metadata in the center ring, providing the most time-saving and energy-efficient data query service for the user. For this method, firstly the data is stored in the UWSN. The storage node is determined, the data is transmitted from the sensor node (data generation source) to the storage node, and the metadata is generated for it. Then, the metadata is sent to the center ring node that is the nearest to the storage node and the data guide map organizes the metadata, diffusing and synchronizing it to the other center ring nodes. Finally, when there is query data in any user node, the data guide map will select a center ring node nearest to the user to process the query sentence, and based on the shortest transmission delay and lowest energy consumption, data transmission routing is generated according to the storage location abstract in the metadata. Hence, specific application data transmission from the storage node to the user is completed. The simulation results demonstrate that DAGM has advantages with respect to data access time and network energy consumption. PMID:29039757
Data Access Based on a Guide Map of the Underwater Wireless Sensor Network.
Wei, Zhengxian; Song, Min; Yin, Guisheng; Song, Houbing; Wang, Hongbin; Ma, Xuefei; Cheng, Albert M K
2017-10-17
Underwater wireless sensor networks (UWSNs) represent an area of increasing research interest, as data storage, discovery, and query of UWSNs are always challenging issues. In this paper, a data access based on a guide map (DAGM) method is proposed for UWSNs. In DAGM, the metadata describes the abstracts of data content and the storage location. The center ring is composed of nodes according to the shortest average data query path in the network in order to store the metadata, and the data guide map organizes, diffuses and synchronizes the metadata in the center ring, providing the most time-saving and energy-efficient data query service for the user. For this method, firstly the data is stored in the UWSN. The storage node is determined, the data is transmitted from the sensor node (data generation source) to the storage node, and the metadata is generated for it. Then, the metadata is sent to the center ring node that is the nearest to the storage node and the data guide map organizes the metadata, diffusing and synchronizing it to the other center ring nodes. Finally, when there is query data in any user node, the data guide map will select a center ring node nearest to the user to process the query sentence, and based on the shortest transmission delay and lowest energy consumption, data transmission routing is generated according to the storage location abstract in the metadata. Hence, specific application data transmission from the storage node to the user is completed. The simulation results demonstrate that DAGM has advantages with respect to data access time and network energy consumption.
Compact Storage Ring for an X-Ray Source
NASA Astrophysics Data System (ADS)
Ovchinnikova, L.; Shvedunov, V.; Ivanov, K.
2017-12-01
We propose a new design of a compact storage ring for a source of X-ray radiation on the basis of reverse Thomson scattering of laser radiation by electrons with the energy of 35-50 MeV, which has small number of optical elements and a significant clear space for the placement of a beam injection-extraction system and a RF cavity. The original laser cavity layout has been considered. The ring dynamic aperture after correction of chromaticity and a second-order dispersion function is sufficient for the injection and stable circulation of an electron bunch in the ring.
Kneipp, Shawn M; Leeman, Jennifer; McCall, Pamela; Hassmiller-Lich, Kristen; Bobashev, Georgiy; Schwartz, Todd A; Gilmore, Robert; Riggan, Scott; Gil, Benjamin
2015-01-01
The adoption and implementation of evidence-based interventions (EBIs) are the goals of translational research; however, potential end-users' perceptions of an EBI value have contributed to low rates of adoption. In this article, we describe our application of emerging dissemination and implementation science theoretical perspectives, community engagement, and systems science principles to develop a novel EBI dissemination approach. Using consumer-driven, graphics-rich simulation, the approach demonstrates predicted implementation effects on health and employment outcomes for socioeconomically disadvantaged women at the local level and is designed to increase adoption interest of county program managers accountable for improving these outcomes in their communities.
Willging, Cathleen E; Aarons, Gregory A; Trott, Elise M; Green, Amy E; Finn, Natalie; Ehrhart, Mark G; Hecht, Debra B
2016-09-01
Sustainment of evidence-based interventions (EBIs) in human services depends on the inner context of community-based organizations (CBOs) that provide services and the outer context of their broader environment. Increasingly, public officials are experimenting with contracting models from for-profit industries to procure human services. In this case study, we conducted qualitative interviews with key government and CBO stakeholders to examine implementation of the Best Value-Performance Information Procurement System to contract for EBIs in a child welfare system. Findings suggest that stakeholder relationships may be compromised when procurement disregards local knowledge, communication, collaboration, and other factors supporting EBIs and public health initiatives.
Burton Richter, Storage Rings, and the J/psi Particle
[SLAC's] Technical Director, [Richter] became Director ... from 1984 through 1999. During his tenure, SLAC Limits of Quantum Electro-dynamics, DOE Technical Report, June 1959 Design Considerations for High Energy Electron -- Positron Storage Rings, DOE Technical Report, November 1966 Inclusive Yields of pi+, pi-, K
Tuning of Schottky barrier height of Al/n-Si by electron beam irradiation
NASA Astrophysics Data System (ADS)
Vali, Indudhar Panduranga; Shetty, Pramoda Kumara; Mahesha, M. G.; Petwal, V. C.; Dwivedi, Jishnu; Choudhary, R. J.
2017-06-01
The effect of electron beam irradiation (EBI) on Al/n-Si Schottky diode has been studied by I-V characterization at room temperature. The behavior of the metal-semiconductor (MS) interface is analyzed by means of variations in the MS contact parameters such as, Schottky barrier height (ΦB), ideality factor (n) and series resistance (Rs). These parameters were found to depend on the EBI dose having a fixed incident beam of energy 7.5 MeV. At different doses (500, 1000, 1500 kGy) of EBI, the Schottky contacts were prepared and extracted their contact parameters by applying thermionic emission and Cheung models. Remarkably, the tuning of ΦB was observed as a function of EBI dose. The improved n with increased ΦB is seen for all the EBI doses. As a consequence of which the thermionic emission is more favored. However, the competing transport mechanisms such as space charge limited emission, tunneling and tunneling through the trap states were ascribed due to n > 1. The analysis of XPS spectra have shown the presence of native oxide and increased radiation induced defect states. The thickness variation in the MS interface contributing to Schottky contact behavior is discussed. This study explains a new technique to tune Schottky contact parameters by metal deposition on the electron beam irradiated n-Si wafers.
NASA Astrophysics Data System (ADS)
Nakamura, Nobuyuki; Ohtani, Shunsuke
2004-01-01
The ninth International Symposium on Electron Beam Ion Sources and Traps and Their Applications — EBIS/T 2004 was held at the Tokyo Metropolitan University (TMU), 15-17 April 2004. There were about 40 participants and about 30 papers presented. The meeting has shown the remarkable progress in science and technology with the EBIS/T machines. In this meeting, besides the normal presentations related to the EBIS/T works, a special session was organized on the last day which was dedicated to Professors N Kobayashi and K Okuno, who have contributed to the EBIS/T development and to the physics of highly charged ions (HCI), to mark their retirement from the TMU in March 2004. In the evening of the first day, there was a laboratory tour where the participants enjoyed seeing the Tokyo EBIT facility and also a beer party in a small hall next to the laboratory. The banquet was held in a traditional Japanese restaurant in a village under Mt Takao with the Japanese meals and performances, after seeing the HCI-research activities in the TMU. The next EBIS/T symposium will be held in Heidelberg in the summer of 2007 as a satellite meeting of XXV ICPEAC. We are looking forward to the next exciting meeting there. Finally, we thank all of TMU staffs and students for their help during the meeting.
Recent charge-breeding developments with EBIS/T devices (invited).
Schwarz, S; Lapierre, A
2016-02-01
Short breeding times, narrow charge state distributions, low background, high efficiency, and the flexible time structure of the ejected low-emittance ion pulses are among the most attractive features of electron beam ion source or trap (EBIS/T) based charge breeders. Significant progress has been made to further improve these properties: Several groups are working to increase current densities towards 10(3) or even 10(4) A/cm(2). These current densities will become necessary to deliver high charge states of heavy nuclei in a short time and/or provide sufficient space-charge capacity to handle high-current ion beams in next-generation rare-isotope beam (RIB) facilities. Efficient capture of continuous beams, attractive because of its potential of handling highest-current ion beams, has become possible with the development of high-density electron beams of >1 A. Requests for the time structure of the charge bred ion pulse range from ultra-short pulses to quasi-continuous beams. Progress is being made on both ends of this spectrum, by either dividing the extracted charge in many pulse-lets, adjusting the extraction potential for a near-uniform long pulse, or adding dedicated devices to spread the ion bunches delivered from the EBIS/T in time. Advances in EBIS/T charge state breeding are summarized, including recent results with NSCL's ReA EBIS/T charge breeder.
Recent charge-breeding developments with EBIS/T devices (invited)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwarz, S., E-mail: schwarz@nscl.msu.edu; Lapierre, A.
Short breeding times, narrow charge state distributions, low background, high efficiency, and the flexible time structure of the ejected low-emittance ion pulses are among the most attractive features of electron beam ion source or trap (EBIS/T) based charge breeders. Significant progress has been made to further improve these properties: Several groups are working to increase current densities towards 10{sup 3} or even 10{sup 4} A/cm{sup 2}. These current densities will become necessary to deliver high charge states of heavy nuclei in a short time and/or provide sufficient space-charge capacity to handle high-current ion beams in next-generation rare-isotope beam (RIB) facilities.more » Efficient capture of continuous beams, attractive because of its potential of handling highest-current ion beams, has become possible with the development of high-density electron beams of >1 A. Requests for the time structure of the charge bred ion pulse range from ultra-short pulses to quasi-continuous beams. Progress is being made on both ends of this spectrum, by either dividing the extracted charge in many pulse-lets, adjusting the extraction potential for a near-uniform long pulse, or adding dedicated devices to spread the ion bunches delivered from the EBIS/T in time. Advances in EBIS/T charge state breeding are summarized, including recent results with NSCL’s ReA EBIS/T charge breeder.« less
Highfield, Linda; Hartman, Marieke A.; Bartholomew, L. Kay; Balihe, Philomene; Ausborn, Valerie A.
2015-01-01
Breast cancer mortality disparities continue, particularly for uninsured and minority women. A number of effective evidence-based interventions (EBIs) exist for addressing barriers to mammography screening; however, their uptake and use in community has been limited. Few cancer-specific studies have evaluated adapted EBIs in new contexts, and fewer still have considered implementation. This study sought to (1) evaluate the effectiveness of an adapted mammography EBI in improving appointment keeping in African American women and (2) describe processes of implementation in a new practice setting. We used the type 1 hybrid design to test effectiveness and implementation using a quasi-experimental design. Logistic regression and intent-to-treat analysis were used to evaluate mammography appointment attendance. The no-show rate was 44% (comparison) versus 19% (intervention). The adjusted odds of a woman in the intervention group attending her appointment were 3.88 (p < 0.001). The adjusted odds of a woman attending her appointment in the intent-to-treat analysis were 2.31 (p < 0.05). Adapted EBI effectiveness was 3.88 (adjusted OR) versus 2.10 (OR) for the original program, indicating enhanced program effect. A number of implementation barriers and facilitators were identified. Our findings support previous studies noting that sequentially measuring EBI efficacy and effectiveness, followed by implementation, may be missing important contextual information. PMID:26504790
NASA Technical Reports Server (NTRS)
Kirk, J. A.; Studer, P. A.; Evans, H. E.
1976-01-01
A new energy storage system (the mechanical capacitor), using a spokeless magnetically levitated composite ring rotor, is described and design formulas for sizing the components are presented. This new system is configured around a permanent magnet (flux biased) suspension which has active servo control in the radial direction and passive control in the axial direction. The storage ring is used as a moving rotor and electronic commutation of the stationary armature coils is proposed. There is no mechanical contact with the rotating spokeless ring; therefore, long life and near zero rundown losses are projected. A 7-kW h system is sized to demonstrate feasibility. A literature review of flywheel energy storage systems is also presented and general formulas are developed for comparing rotor geometries.
MULTI-OBJECTIVE ONLINE OPTIMIZATION OF BEAM LIFETIME AT APS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Yipeng
In this paper, online optimization of beam lifetime at the APS (Advanced Photon Source) storage ring is presented. A general genetic algorithm (GA) is developed and employed for some online optimizations in the APS storage ring. Sextupole magnets in 40 sectors of the APS storage ring are employed as variables for the online nonlinear beam dynamics optimization. The algorithm employs several optimization objectives and is designed to run with topup mode or beam current decay mode. Up to 50\\% improvement of beam lifetime is demonstrated, without affecting the transverse beam sizes and other relevant parameters. In some cases, the top-upmore » injection efficiency is also improved.« less
National Synchrotron Light Source annual report 1991
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hulbert, S.L.; Lazarz, N.M.
1992-04-01
This report discusses the following research conducted at NSLS: atomic and molecular science; energy dispersive diffraction; lithography, microscopy and tomography; nuclear physics; UV photoemission and surface science; x-ray absorption spectroscopy; x-ray scattering and crystallography; x-ray topography; workshop on surface structure; workshop on electronic and chemical phenomena at surfaces; workshop on imaging; UV FEL machine reviews; VUV machine operations; VUV beamline operations; VUV storage ring parameters; x-ray machine operations; x-ray beamline operations; x-ray storage ring parameters; superconducting x-ray lithography source; SXLS storage ring parameters; the accelerator test facility; proposed UV-FEL user facility at the NSLS; global orbit feedback systems; and NSLSmore » computer system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xi; Huang, Xiaobiao
2016-05-13
Here, we propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. Finally, the method has been successfully demonstrated on the NSLS-II storage ring.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xi; Huang, Xiaobiao
2016-08-01
We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. Furthermore, the fitting results are used for lattice correction. Our method has been successfully demonstrated on the NSLS-II storage ring.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xi; Huang, Xiaobiao
2016-08-01
We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. The method has been successfully demonstrated on the NSLS-II storage ring.
NSLS-II storage ring insertion device and front-end commissioning and operation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, G., E-mail: gwang@bnl.gov; Shaftan, T.; Amundsen, C.
The National Synchrotron Light Source II (NSLS-II) is a state of the art 3 GeV third generation light source at Brookhaven National Laboratory. During spring/ summer of 2014, the storage ring was commissioned up to 50 mA without insertion devices. In the fall of 2014, we began commissioning of the project beamlines, which included seven insertion devices on six ID ports. Beamlines IXS, HXN, CSX-1, CSX-2, CHX, SRX, and XPD-1 consist of elliptically polarized undulator (EPU), damping wigglers (DW) and in-vacuum undulators (IVU) covering from VUV to hard x-ray range. In this paper, experience with commissioning and operation is discussed.more » We focus on reaching storage ring performance with IDs, including injection, design emittance, compensation of orbit distortions caused by ID residual field, source point stability, beam alignment and tools for control, monitoring and protection of the ring chambers from ID radiation.« less
Fluorescence decay of naphthalene studied in an electrostatic storage ring, the Mini-Ring
NASA Astrophysics Data System (ADS)
Martin, S.; Matsumoto, J.; Kono, N.; Ji, M.-C.; Brédy, R.; Bernard, J.; Cassimi, A.; Chen, L.
2017-10-01
The cooling of naphthalene cations (C10H8)+ has been studied in a compact electrostatic ion storage ring, the Mini-Ring. A nano second laser pulse of 532 nm (2.33 eV) was used to probe the internal energy distribution every millisecond during the storage time up to 5 ms. The evolution of the internal energy distribution of the stored ions was simulated with a model taking into account the dissociation and the radiative decay processes. Calculated decay curves were fitted to the corresponding laser induced neutral decays. For a laser power of 200 μJ/pulse, a good agreement between experiment and modeling was found using an initial Gaussian energy distribution centered to 5.9 eV and a fluorescence decay rate varying from 200 to 300 s-1 in the energy range from 6 to 7 eV. This fast decay was attributed to the delayed Poincaré fluorescence process.
Colliding or co-rotating ion beams in storage rings for EDM search
NASA Astrophysics Data System (ADS)
Koop, I. A.
2015-11-01
A new approach to search for and measure the electric dipole moment (EDM) of the proton, deuteron and some other light nuclei is presented. The idea of the method is to store two ion beams, circulating with different velocities, in a storage ring with crossed electric and magnetic guiding fields. One beam is polarized and its EDM is measured using the so-called ‘frozen spin’ method. The second beam, which is unpolarized, is used as a co-magnetometer, sensitive to the radial component of the ring’s magnetic field. The particle’s magnetic dipole moment (MDM) couples to the radial magnetic field and mimics the EDM signal. Measuring the relative vertical orbit separation of the two beams, caused by the presence of the radial magnetic field, one can control the unwanted MDM spin precession. Examples of the parameters for EDM storage rings for protons and other species of ions are presented. The use of crossed electric and magnetic fields helps to reduce the size of the ring by a factor of 10-20. We show that the bending radius of such an EDM storage ring could be about 2-3 m. Finally, a new method of increasing the spin coherence time, the so-called ‘spin wheel’, is proposed and its applicability to the EDM search is discussed.
Tree- Rings Link Climate and Carbon Storage in a Northern Mixed Hardwood Forest
NASA Astrophysics Data System (ADS)
Chiriboga, A.
2007-12-01
The terrestrial biosphere is a variable sink for atmospheric carbon dioxide. It is important to understand how carbon storage in trees is affected by natural climate variability to better characterize the sink. Quantifying the sensitivity of forest carbon storage to climate will improve carbon budgets and have implications for forest management practices. Here we explore how climate variability affects the ability of a northern mixed hardwood forest in Michigan to sequester atmospheric carbon dioxide in woody tissues. This site is ideal for studies of carbon sequestration; The University of Michigan Biological Station is an Ameriflux site, and has detailed meteorological and biometric records, as well as CO2 flux data. We have produced an 82- year aspen (Populus grandidentata) tree-ring chronology for this site, and measured ring widths at several heights up the bole. These measurements were used to estimate annual wood volume, which represents carbon allocated to aboveground carbon stores. Standard dendroclimatological techniques are used to identify environmental factors (e.g. temperature or precipitation) that drive tree-ring increment variability in the past century, and therefore annual carbon storage in this forest. Preliminary results show that marker years within the tree- ring chronology correspond with years that have cold spring temperatures. This suggests that trees at this site are temperature sensitive.
Beam Loss Measurements at the Los Alamos Proton Storage Ring
NASA Astrophysics Data System (ADS)
Spickermann, Thomas
2005-06-01
During normal operation the Los Alamos Proton Storage Ring (PSR) accumulates up to 4ṡ1013 protons over 625μs with a repetition rate of 20 Hz, corresponding to a current of 125μA to the Lujan Neutron Science Center. Beam losses in the ring as well as in the extraction beam line and the subsequent activation of material are a limiting factor at these currents. Careful tuning of injection, ring and extraction line is paramount to limiting losses to acceptable levels. Losses are typically not uniform around the ring, but occur in significantly higher levels in certain "hot spots". Here I will report on losses related to the stripper foil which are the dominant source of losses in the ring. First results of a comparison with simulations will also be presented.
Nitrile O-ring Cracking: A Case of Vacuum Flange O-ring Failures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dees, Craig
2016-07-01
A review of recent nitrile O-ring failures in ISO-KF vacuum flange connections in glovebox applications is presented. An investigation of a single “isolated” o-ring failure leads to the discovery of cracked nitrile o-rings in a glovebox atmospheric control unit. The initial cause of the o-ring failure is attributed to ozone degradation. However, additional investigation reveals nitrile o-ring cracking on multiple gloveboxes and general purpose piping, roughly 85% of the nitrile o-rings removed for inspection show evidence of visible cracking after being in service for 18 months or less. The results of material testing and ambient air testing is presented, elevatedmore » ozone levels are not found. The contributing factors of o-ring failure, including nitrile air sensitivity, inadequate storage practices, and poor installation techniques, are discussed. A discussion of nitrile o-ring material properties, the benefits and limitations, and alternate materials are discussed. Considerations for o-ring material selection, purchasing, storage, and installation are presented in the context of lessons learned from the nitrile o-ring cracking investigation. This paper can be presented in 20 minutes and does not require special accommodations or special audio visual devices.« less
An analog RF gap voltage regulation system for the Advanced Photon Source storage ring.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Horan, D.
1999-04-13
An analog rf gap voltage regulation system has been designed and built at Argonne National Laboratory to maintain constant total storage ring rf gap voltage, independent of beam loading and cavity tuning effects. The design uses feedback control of the klystron mod-anode voltage to vary the amount of rf power fed to the storage ring cavities. The system consists of two independent feedback loops, each regulating the combined rf gap voltages of eight storage ring cavities by varying the output power of either one or two rf stations, depending on the mode of operation. It provides full operator control andmore » permissive logic to permit feedback control of the rf system output power only if proper conditions are met. The feedback system uses envelope-detected cavity field probe outputs as the feedback signal. Two different methods of combining the individual field probe signals were used to generate a relative DC level representing one-half of the total storage ring rf voltage, an envelope-detected vector sum of the field probe rf signals, and the DC sum of individual field probe envelope detector outputs. The merits of both methods are discussed. The klystron high-voltage power supply (HVPS) units are fitted with an analog interface for external control of the mod-anode voltage level, using a four-quadrant analog multiplier to modulate the HVPS mod-anode voltage regulator set-point in response to feedback system commands.« less
Martin, Aiden A.; Bahm, Alan; Bishop, James; ...
2015-12-15
Here, we report highly ordered topographic patterns that form on the surface of diamond, span multiple length scales, and have a symmetry controlled by the precursor gas species used in electron-beam-induced etching (EBIE). The pattern formation dynamics reveals an etch rate anisotropy and an electron energy transfer pathway that is overlooked by existing EBIE models. Therefore, we, modify established theory such that it explains our results and remains universally applicable to EBIE. Furthermore, the patterns can be exploited in controlled wetting, optical structuring, and other emerging applications that require nano- and microscale surface texturing of a wide band-gap material.
Willging, Cathleen E.; Aarons, Gregory A.; Trott, Elise M.; Green, Amy E.; Finn, Natalie; Ehrhart, Mark G.; Hecht, Debra B.
2016-01-01
Sustainment of evidence-based interventions (EBIs) in human services depends on the inner context of community-based organizations (CBOs) that provide services and the outer context of their broader environment. Increasingly, public officials are experimenting with contracting models from for-profit industries to procure human services. In this case study, we conducted qualitative interviews with key government and CBO stakeholders to examine implementation of the Best Value-Performance Information Procurement System to contract for EBIs in a child welfare system. Findings suggest that stakeholder relationships may be compromised when procurement disregards local knowledge, communication, collaboration, and other factors supporting EBIs and public health initiatives. PMID:26386977
Analysis of Methods to Excite Head-Tail Motion Within the Cornell Electron Storage Ring
NASA Astrophysics Data System (ADS)
Gendler, Naomi; Billing, Mike; Shanks, Jim
The main accelerator complex at Cornell consists of two rings around which electrons and positrons move: the synchrotron, where the particles are accelerated to 5 GeV, and the Storage Ring, where the particles circulate a ta Þxed energy, guided by quadrupole and dipole magnets, with a steady energy due to a sinusoidal voltage source. Keeping the beam stable in the Storage Ring is crucial for its lifetime. A long-lasting, invariable beam means more accurate experiments, as well as brighter, more focused X-rays for use in the Cornell High Energy Synchrotron Source (CHESS). The stability of the electron and positron beams in the Cornell Electron Storage Ring (CESR) is important for the development of accelerators and for usage of the beam in X-ray science and accelerator physics. Bunch oscillations tend to enlarge the beam's cross section, making it less stable. We believe that one such oscillation is ``head-tail motion,'' where the bunch rocks back and forth on a pivot located at the central particle. In this project, we write a simulation of the bunch that induces head-tail motion with a vertical driver. We also excite this motion physically in the storage ring, and observe a deÞnite head-tail signal. In the experiment, we saw a deÞnite persistence of the drive-damp signal within a small band around the head-tail frequency, indicating that the head-tail frequency is a natural vertical mode of the bunch that was being excited. The signal seen in the experiment matched the signal seen in the simulation to within an order of magnitude.
Is Personalized Learning the Future of School?
ERIC Educational Resources Information Center
Paz-Albo, Jesús
2017-01-01
This article describes an innovative teaching approach that can offer the changes needed for school improvement. When entering an Education: Basic and Interactive (EBI) classroom, one will see students focused on accomplishing self-guided tasks and eager to move on to the next challenge in their self-paced learning. The EBI Project described here…
The European Bioinformatics Institute's data resources: towards systems biology.
Brooksbank, Catherine; Cameron, Graham; Thornton, Janet
2005-01-01
Genomic and post-genomic biological research has provided fine-grain insights into the molecular processes of life, but also threatens to drown biomedical researchers in data. Moreover, as new high-throughput technologies are developed, the types of data that are gathered en masse are diversifying. The need to collect, store and curate all this information in ways that allow its efficient retrieval and exploitation is greater than ever. The European Bioinformatics Institute's (EBI's) databases and tools have evolved to meet the changing needs of molecular biologists: since we last wrote about our services in the 2003 issue of Nucleic Acids Research, we have launched new databases covering protein-protein interactions (IntAct), pathways (Reactome) and small molecules (ChEBI). Our existing core databases have continued to evolve to meet the changing needs of biomedical researchers, and we have developed new data-access tools that help biologists to move intuitively through the different data types, thereby helping them to put the parts together to understand biology at the systems level. The EBI's data resources are all available on our website at http://www.ebi.ac.uk.
The European Bioinformatics Institute's data resources: towards systems biology
Brooksbank, Catherine; Cameron, Graham; Thornton, Janet
2005-01-01
Genomic and post-genomic biological research has provided fine-grain insights into the molecular processes of life, but also threatens to drown biomedical researchers in data. Moreover, as new high-throughput technologies are developed, the types of data that are gathered en masse are diversifying. The need to collect, store and curate all this information in ways that allow its efficient retrieval and exploitation is greater than ever. The European Bioinformatics Institute's (EBI's) databases and tools have evolved to meet the changing needs of molecular biologists: since we last wrote about our services in the 2003 issue of Nucleic Acids Research, we have launched new databases covering protein–protein interactions (IntAct), pathways (Reactome) and small molecules (ChEBI). Our existing core databases have continued to evolve to meet the changing needs of biomedical researchers, and we have developed new data-access tools that help biologists to move intuitively through the different data types, thereby helping them to put the parts together to understand biology at the systems level. The EBI's data resources are all available on our website at http://www.ebi.ac.uk. PMID:15608238
Crowley, D Max; Greenberg, Mark T; Feinberg, Mark E; Spoth, Richard L; Redmond, Cleve R
2012-02-01
A substantial challenge in improving public health is how to facilitate the local adoption of evidence-based interventions (EBIs). To do so, an important step is to build local stakeholders' knowledge and decision-making skills regarding the adoption and implementation of EBIs. One EBI delivery system, called PROSPER (PROmoting School-community-university Partnerships to Enhance Resilience), has effectively mobilized community prevention efforts, implemented prevention programming with quality, and consequently decreased youth substance abuse. While these results are encouraging, another objective is to increase local stakeholder knowledge of best practices for adoption, implementation and evaluation of EBIs. Using a mixed methods approach, we assessed local stakeholder knowledge of these best practices over 5 years, in 28 intervention and control communities. Results indicated that the PROSPER partnership model led to significant increases in expert knowledge regarding the selection, implementation, and evaluation of evidence-based interventions. Findings illustrate the limited programming knowledge possessed by members of local prevention efforts, the difficulty of complete knowledge transfer, and highlight one method for cultivating that knowledge.
Developing a Policy Flight Simulator to Facilitate the Adoption of an Evidence-Based Intervention
Yu, Zhongyuan; Hirschman, Karen B.; Pepe, Kara; Pauly, Mark V.; Naylor, Mary D.; Rouse, William B.
2018-01-01
While the use of evidence-based interventions (EBIs) has been advocated by the medical research community for quite some time, uptake of these interventions by healthcare providers has been slow. One possible explanation is that it is challenging for providers to estimate impacts of a specific EBI on their particular organization. To address that concern, we developed and evaluated a type of simulation called a policy flight simulator to determine if it could improve the adoption decision about a specific EBI, the transitional care model (TCM). The TCM uses an advanced practice nurse-led model of care to transition older adults with multiple chronic conditions from a hospitalization to home. An evaluation by a National Advisory Committee, made up of senior representatives from various stakeholders in the U.S. healthcare system, found the policy flight simulator to be a useful tool that has the potential to better inform adoption decisions. This paper describes the simulation development effort and documents lessons learned that may be useful to the healthcare modeling community and those interested in using simulation to support decisions based on EBIs. PMID:29805921
Beam vacuum system of Brookhaven`s muon storage ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hseuth, H.C.; Snydstrup, L.; Mapes, M.
1995-11-01
A storage ring with a circumference of 45 m is being built at Brookhaven to measure the g-2 value of the muons to an accuracy of 0.35 ppm.. The beam vacuum system of the storage ring will operate at 10{sup -7} Torr and has to be completely non-magnetic. It consists of twelve sector chambers. The chambers are constructed of aluminum and are approximately 3.5 m in length with a rectangular cross-section of 16.5 cm high by 45 cm at the widest point. The design features, fabrication techniques and cleaning methods for these chambers are described. The beam vacuum system willmore » be pumped by forty eight non-magnetic distributed ion pumps with a total pumping speed of over 2000 {ell}/sec. Monte Carlo simulations of the pressure distribution in the muon storage region are presented.« less
Bendtsen, Preben; Müssener, Ulrika; Karlsson, Nadine; López-Pelayo, Hugo; Palacio-Vieira, Jorge; Colom, Joan; Gual, Antoni; Reynolds, Jillian; Wallace, Paul; Segura, Lidia; Anderson, Peter
2016-01-01
Objectives The objective of the present study was to explore whether the possibility of offering facilitated access to an alcohol electronic brief intervention (eBI) instead of delivering brief face-to-face advice increased the proportion of consulting adults who were screened and given brief advice. Design The study was a 12-week implementation study. Sixty primary healthcare units (PHCUs) in 5 jurisdictions (Catalonia, England, the Netherlands, Poland and Sweden) were asked to screen adults who attended the PHCU for risky drinking. Setting A total of 120 primary healthcare centres from 5 jurisdictions in Europe. Participants 746 individual providers (general practitioners, nurses or other professionals) participated in the study. Primary outcome Change in the proportion of patients screened and referred to eBI comparing a baseline 4-week preimplementation period with a 12-week implementation period. Results The possibility of referring patients to the eBI was not found to be associated with any increase in the proportion of patients screened. However, it was associated with an increase in the proportion of screen-positive patients receiving brief advice from 70% to 80% for the screen-positive sample as a whole (p<0.05), mainly driven by a significant increase in brief intervention rates in England from 87% to 96% (p<0.01). The study indicated that staff displayed a low level of engagement in this new technology. Staff continued to offer face-to-face advice to a larger proportion of patients (54%) than referral to eBI (38%). In addition, low engagement was seen among the referred patients; on average, 18% of the patients logged on to the website with a mean log-on rate across the different countries between 0.58% and 36.95%. Conclusions Referral to eBI takes nearly as much time as brief oral advice and might require more introduction and training before staff are comfortable with referring to eBI. Trial registration number NCT01501552; Post-results. PMID:27311902
Evaluation and Cross-Comparison of Lexical Entities of Biological Interest (LexEBI)
Rebholz-Schuhmann, Dietrich; Kim, Jee-Hyub; Yan, Ying; Dixit, Abhishek; Friteyre, Caroline; Hoehndorf, Robert; Backofen, Rolf; Lewin, Ian
2013-01-01
Motivation Biomedical entities, their identifiers and names, are essential in the representation of biomedical facts and knowledge. In the same way, the complete set of biomedical and chemical terms, i.e. the biomedical “term space” (the “Lexeome”), forms a key resource to achieve the full integration of the scientific literature with biomedical data resources: any identified named entity can immediately be normalized to the correct database entry. This goal does not only require that we are aware of all existing terms, but would also profit from knowing all their senses and their semantic interpretation (ambiguities, nestedness). Result This study compiles a resource for lexical terms of biomedical interest in a standard format (called “LexEBI”), determines the overall number of terms, their reuse in different resources and the nestedness of terms. LexEBI comprises references for protein and gene entries and their term variants and chemical entities amongst other terms. In addition, disease terms have been identified from Medline and PubmedCentral and added to LexEBI. Our analysis demonstrates that the baseforms of terms from the different semantic types show only little polysemous use. Nonetheless, the term variants of protein and gene names (PGNs) frequently contain species mentions, which should have been avoided according to protein annotation guidelines. Furthermore, the protein and gene entities as well as the chemical entities, both do comprise enzymes leading to hierarchical polysemy, and a large portion of PGNs make reference to a chemical entity. Altogether, according to our analysis based on the Medline distribution, 401,869 unique PGNs in the documents contain a reference to 25,022 chemical entities, 3,125 disease terms or 1,576 species mentions. Conclusion LexEBI delivers the complete biomedical and chemical Lexeome in a standardized representation (http://www.ebi.ac.uk/Rebholz-srv/LexEBI/). The resource provides the disease terms as open source content, and fully interlinks terms across resources. PMID:24124474
Husain, Mansourah; Martin, Samuel A M; Wang, Tiehui
2014-11-01
Interleukin (IL)-27 is an IL-6/IL-12 family member with pro-inflammatory and anti-inflammatory properties. It is a heterodimeric cytokine composed of an α-chain p28 and a β-chain Ebi3 (Epstein-Barr virus induce gene 3). The p28 subunit can also be secreted as a monomer and function as IL-30 that acts as an inhibitor of IL-27 signalling. At present, the p28 gene has only been described in mammals. Thus, for the first time outwith mammals, we have identified seven p28 molecules in six divergent teleost fish species, Atlantic salmon, two cichlids, two cyprinids and a yellowtail. The fish p28 molecules have higher similarities to mammalian p28 than other IL-6/12 family members. Critical residues involved in the interaction with Ebi3 and the receptor gp130 are highly conserved. The prediction that these are true orthologues is supported by phylogenetic and synteny analysis. Two p28 paralogues (p28a and p28b) sharing 72% aa identity have been identified and characterised in Atlantic salmon. There are multiple upstream ATGs in the 5'-UTR and ATTTA motifs in the 3'-UTR of both cDNA sequences, suggesting regulation at the post-transcriptional and translational level. Both salmon p28 genes are highly expressed in immune relevant tissues, such as thymus, gills, spleen and head kidney. Conversely salmon Ebi3 is highly expressed in other organs, such as liver and caudal kidney. The expression of p28 but not Ebi3 was induced by PAMPs and recombinant cytokines in head kidney cells, and in spleen by Poly I:C challenge in vivo. The dissociation of the expression and modulation of p28 and Ebi3 suggest that both p28 and Ebi3 may be secreted alone or with other partners. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Silenko, Alexander J.
2017-10-01
We calculate the corrections for constant radial magnetic field in muon {g}-2 and electric-dipole-moment experiments in storage rings. While the correction is negligible for the current generation of {g}-2 experiments, it affects the upcoming muon electric-dipole-moment experiment at Fermilab.
Loss-free method of charging accumulator rings
Maschke, Alfred W.
1979-01-01
A method for the production of high current pulses of heavy ions having an atomic weight greater than 100. Also a linear accelerator based apparatus for carrying out said method. Pulses formed by the method of the subject invention are suitable for storage in a storage ring. The accumulated pulses may be used in inertial fusion apparatus.
National Synchrotron Light Source annual report 1991. Volume 1, October 1, 1990--September 30, 1991
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hulbert, S.L.; Lazarz, N.M.
1992-04-01
This report discusses the following research conducted at NSLS: atomic and molecular science; energy dispersive diffraction; lithography, microscopy and tomography; nuclear physics; UV photoemission and surface science; x-ray absorption spectroscopy; x-ray scattering and crystallography; x-ray topography; workshop on surface structure; workshop on electronic and chemical phenomena at surfaces; workshop on imaging; UV FEL machine reviews; VUV machine operations; VUV beamline operations; VUV storage ring parameters; x-ray machine operations; x-ray beamline operations; x-ray storage ring parameters; superconducting x-ray lithography source; SXLS storage ring parameters; the accelerator test facility; proposed UV-FEL user facility at the NSLS; global orbit feedback systems; and NSLSmore » computer system.« less
Low emittance lattice for the storage ring of the Turkish Light Source Facility TURKAY
NASA Astrophysics Data System (ADS)
Nergiz, Z.; Aksoy, A.
2015-06-01
The TAC (Turkish Accelerator Center) project aims to build an accelerator center in Turkey. The first stage of the project is to construct an Infra-Red Free Electron Laser (IR-FEL) facility. The second stage is to build a synchrotron radiation facility named TURKAY, which is a third generation synchrotron radiation light source that aims to achieve a high brilliance photon beam from a low emittance electron beam at 3 GeV. The electron beam parameters are highly dependent on the magnetic lattice of the storage ring. In this paper a low emittance storage ring for TURKAY is proposed and the beam dynamic properties of the magnetic lattice are investigated. Supported by Turkish Republic Ministry of Development (DPT2006K120470)
PEGASYS---A proposed internal target facility for the PEP storage ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Biber, K.
A proposal for an integral gas-jet target and forward spectrometer for the PEP storage ring is described. The beam structure, allowable, luminosity (L = 10/sup 33/ cm/sup /minus/2/s/sup /minus/1/ for H/sub 2/, D/sub 2/) and energy (E/sub e/ less than or equal to 15 GeV) make the ring ideal for multiparticle coincidence studies in the scaling regime, and where perturbative QCD may be an apt description of some exclusive and semi-inclusive reactions. 14 refs., 7 figs.
ERIC Educational Resources Information Center
Wang, Xihui; Zhang, Zhidong; Zhang, Xiuying; Hou, Dadong
2013-01-01
The Epistemic Beliefs Inventory (EBI), as a theory-based and empirically validated instrument, was originally developed and widely used in the North American context. Through a strict translation procedure the authors translated the EBI into Chinese, and then administered it to 451 students in 7 universities in mainland China. The construct…
Children's Executive Functions: Are They Poorer after Very Early Brain Insult
ERIC Educational Resources Information Center
Anderson, Vicki; Spencer-Smith, Megan; Coleman, Lee; Anderson, Peter; Williams, Jackie; Greenham, Mardee; Leventer, Richard J.; Jacobs, Rani
2010-01-01
Traditionally early brain insult (EBI) has been considered to have better outcome than later injury, consistent with the notion that the young brain is flexible and able to reorganize. Recent research findings question this view, suggesting that EBI might lead to poorer outcome than brain insult at any other age. Exploring this early vulnerability…
The Conceptualization, Integration, and Support of Evidence-Based Interventions in the Schools
ERIC Educational Resources Information Center
Becker, Kimberly D.; Domitrovich, Celene E.
2011-01-01
The studies in this issue break the mold of the traditional stage model of the development and testing of evidence-based interventions (EBIs) within the confines of highly controlled studies (Onken, Blaine, & Battjes, 1997). Although this approach has merits, the need for EBIs in school settings has outpaced their deployment. The authors of these…
ERIC Educational Resources Information Center
Hoover, Kristin Nicole
2013-01-01
The purpose of the study was to examine the relationship between EBI training for special education teachers and their practice of classroom interventions for children with an autism spectrum disorder (ASD). Evaluating the usage of EBIs in the classroom is imperative because of the many obligations educators have to uphold federal compliances…
ERIC Educational Resources Information Center
Brandt Brecheisen, Shannon M.
2014-01-01
The purpose of this national, quantitative study was to (1) provide psychometrics for the ACUHO-I/EBI RA Survey, a joint project between between Educational Benchmarking, Inc (EBI) and The Association of College and University Housing Officers--International (ACUHO-I), and (2) explore the sophomore resident assistant (RA) experience. This study…
NASA Astrophysics Data System (ADS)
Kponou, A.; Beebe, E.; Pikin, A.; Kuznetsov, G.; Batazova, M.; Tiunov, M.
1998-02-01
Presented is a report on the development of an electron-beam ion source (EBIS) for the relativistic heavy ion collider at Brookhaven National Laboratory (BNL) which requires operating with a 10 A electron beam. This is approximately an order of magnitude higher current than in any existing EBIS device. A test stand is presently being designed and constructed where EBIS components will be tested. It will be reported in a separate paper at this conference. The design of the 10 A electron gun, drift tubes, and electron collector requires extensive computer simulations. Calculations have been performed at Novosibirsk and BNL using two different programs, SAM and EGUN. Results of these simulations will be presented.
The European Bioinformatics Institute's data resources 2014.
Brooksbank, Catherine; Bergman, Mary Todd; Apweiler, Rolf; Birney, Ewan; Thornton, Janet
2014-01-01
Molecular Biology has been at the heart of the 'big data' revolution from its very beginning, and the need for access to biological data is a common thread running from the 1965 publication of Dayhoff's 'Atlas of Protein Sequence and Structure' through the Human Genome Project in the late 1990s and early 2000s to today's population-scale sequencing initiatives. The European Bioinformatics Institute (EMBL-EBI; http://www.ebi.ac.uk) is one of three organizations worldwide that provides free access to comprehensive, integrated molecular data sets. Here, we summarize the principles underpinning the development of these public resources and provide an overview of EMBL-EBI's database collection to complement the reviews of individual databases provided elsewhere in this issue.
The KACST Heavy-Ion Electrostatic Storage Ring
NASA Astrophysics Data System (ADS)
Almuqhim, A. A.; Alshammari, S. M.; El Ghazaly, M. O. A.; Papash, A. I.; Welsch, C. P.
2011-10-01
A novel Electrostatic Storage Ring (ESR) for beams at energies up to 30keV/q is now being constructed at the National Centre for Mathematics and Physics (NCMP), King Abdul-Aziz City for Science and Technology (KACST). The ring is designed to be the core of a highly flexible experimental platform that will combine a large package of complementary beam techniques for atomic and molecular physics and related fields. The lattice design had to cover the different experimental techniques that the ring will be equipped with, such as e.g. Electron-Ion, Laser-Ion, Ion-Ion or Ion-Neutral beams, in both crossed and merged-beam configurations. The development of such an ESR is realized in a staged approach, in which a simple and early-run adaptation of the ring is built first, and then this basic version is upgraded to a higher symmetry of the ultimate version of the ring. Here, we report a general overview of this technical development with a focus on the layout of the first built stage of the ring.
BEAM DIAGNOSTICS USING BPM SIGNALS FROM INJECTED AND STORED BEAMS IN A STORAGE RING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, G.M.; Shaftan; T.
2011-03-28
Many modern light sources are operating in top-off injection mode or are being upgraded to top-off injection mode. The storage ring always has the stored beam and injected beam for top-off injection mode. So the BPM data is the mixture of both beam positions and the injected beam position cannot be measured directly. We propose to use dedicated wide band BPM electronics in the NSLS II storage ring to retrieve the injected beam trajectory with the singular value decomposition (SVD) method. The beam position monitor (BPM) has the capability to measure bunch-by-bunch beam position. Similar electronics can be used tomore » measure the bunch-by-bunch beam current which is necessary to get the injection beam position. The measurement precision of current needs to be evaluated since button BPM sum signal has position dependence. The injected beam trajectory can be measured and monitored all the time without dumping the stored beam. We can adjust and optimize the injected beam trajectory to maximize the injection efficiency. We can also measure the storage ring acceptance by mapping the injected beam trajectory.« less
First storage of ion beams in the Double Electrostatic Ion-Ring Experiment: DESIREE.
Schmidt, H T; Thomas, R D; Gatchell, M; Rosén, S; Reinhed, P; Löfgren, P; Brännholm, L; Blom, M; Björkhage, M; Bäckström, E; Alexander, J D; Leontein, S; Hanstorp, D; Zettergren, H; Liljeby, L; Källberg, A; Simonsson, A; Hellberg, F; Mannervik, S; Larsson, M; Geppert, W D; Rensfelt, K G; Danared, H; Paál, A; Masuda, M; Halldén, P; Andler, G; Stockett, M H; Chen, T; Källersjö, G; Weimer, J; Hansen, K; Hartman, H; Cederquist, H
2013-05-01
We report on the first storage of ion beams in the Double ElectroStatic Ion Ring ExpEriment, DESIREE, at Stockholm University. We have produced beams of atomic carbon anions and small carbon anion molecules (C(n)(-), n = 1, 2, 3, 4) in a sputter ion source. The ion beams were accelerated to 10 keV kinetic energy and stored in an electrostatic ion storage ring enclosed in a vacuum chamber at 13 K. For 10 keV C2 (-) molecular anions we measure the residual-gas limited beam storage lifetime to be 448 s ± 18 s with two independent detector systems. Using the measured storage lifetimes we estimate that the residual gas pressure is in the 10(-14) mbar range. When high current ion beams are injected, the number of stored particles does not follow a single exponential decay law as would be expected for stored particles lost solely due to electron detachment in collision with the residual-gas. Instead, we observe a faster initial decay rate, which we ascribe to the effect of the space charge of the ion beam on the storage capacity.
Beam position monitoring system at CESR
NASA Astrophysics Data System (ADS)
Billing, M. G.; Bergan, W. F.; Forster, M. J.; Meller, R. E.; Rendina, M. C.; Rider, N. T.; Sagan, D. C.; Shanks, J.; Sikora, J. P.; Stedinger, M. G.; Strohman, C. R.; Palmer, M. A.; Holtzapple, R. L.
2017-09-01
The Cornell Electron-positron Storage Ring (CESR) has been converted from a High Energy Physics electron-positron collider to operate as a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS) and to conduct accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Some of the specific topics that were targeted for the initial phase of operation of the storage ring in this mode, labeled CESRTA (CESR as a Test Accelerator), included 1) tuning techniques to produce low emittance beams, 2) the study of electron cloud development in a storage ring and 3) intra-beam scattering effects. The complete conversion of CESR to CESRTA occurred over a several year period and is described elsewhere. As a part of this conversion the CESR beam position monitoring (CBPM) system was completely upgraded to provide the needed instrumental capabilities for these studies. This paper describes the new CBPM system hardware, its function and representative measurements performed by the upgraded system.
The Role of Collaborations in Sustaining an Evidence-Based Intervention to Reduce Child Neglect
Green, Amy E.; Trott, Elise; Willging, Cathleen E.; Finn, Natalie K.; Ehrhart, Mark G.; Aarons, Gregory A.
2016-01-01
Child neglect is the most prevalent form of child maltreatment and represents 79.5% of open child-welfare cases. A recent study found the evidence-based intervention (EBI) SafeCare® (SC) to significantly reduce child neglect recidivism rates. To fully capitalize on the effectiveness of such EBIs, service systems must engage in successful implementation and sustainment; however, little is known regarding what factors influence EBI sustainment. Collaborations among stakeholders are suggested as a means for facilitating EBI implementation and sustainment. This study combines descriptive quantitative survey data with qualitative interview and focus group findings to examine the role of collaboration within the context of public-private partnerships in 11 child welfare systems implementing SC. Participants included administrators of government child welfare systems and community-based organizations, as well as supervisors, coaches, and home visitors of the SC program. Sites were classified as fully-, partially-, and non-sustaining based on implementation fidelity. One-way analysis of variance was used to examine differences in stakeholder reported Effective Collaboration scores across fully-sustaining, partially-sustaining, and non-sustaining sites. Qualitative transcripts were analyzed via open and focused coding to identify the commonality, diversity, and complexity of collaborations involved in implementing and sustaining SC. Fully-sustaining sites reported significantly greater levels of effective collaboration than non-sustaining sites. Key themes described by SC stakeholders included shared vision, building on existing relationships, academic support, problem solving and resource sharing, and maintaining collaborations over time. Both quantitative and qualitative results converge in highlighting the importance of effective collaboration in EBI sustainment in child welfare service systems. PMID:26712422
ERIC Educational Resources Information Center
Paechter, Manuela; Rebmann, Karin; Schloemer, Tobias; Mokwinski, Bjoern; Hanekamp, Yvonne; Arendasy, Martin
2013-01-01
The present research describes the development of a German questionnaire for measurement of domain-general epistemic beliefs. Pre-studies on the psychometric properties of a German version of the Epistemic Beliefs Inventory (EBI) had emphasized the necessity to develop an instrument that is especially constructed for German-speaking samples. The…
Tiruneh, Abebe; Siman-Tov, Maya; Radomislensky, Irina; Itg; Peleg, Kobi
2017-02-01
To examine whether characteristics and circumstances of injuries are related to ethnicity. The study was based on the Israeli National Trauma Registry data for patients hospitalized between 2008 and 2011. Data included demographics, injury, hospital resource utilization characteristics and outcome at discharge. Univariate analysis followed by logistic regression models were undertaken to examine the relationship between injury and ethnicity. The study included 116,946 subjects; 1% were Ethiopian Born Israelis (EBI), 11% Israelis born in the Former Soviet Union (FSUBI) and 88% the remaining Israelis (RI). EBI were injured more on street or at work place and had higher rates of penetrating and severe injuries. However, FSUBI were mostly injured at home, and had higher rates of fall injuries and hip fracture. Adjusted analysis showed that EBI and FSUBI were more likely to be hospitalized because of violence-related injuries compared with RI but less likely because of road traffic injuries. Undergoing surgery and referral for rehabilitation were greater among FSUBI, while admission to intensive care unit was greater among EBI. Targeted intervention programmes need to be developed for immigrants of different countries of origin in accordance with the identified characteristics.
Lessons Learned From Dissemination of Evidence-Based Interventions for HIV Prevention.
Collins, Charles B; Sapiano, Tobey N
2016-10-01
In 1999, IOM issued a report that recommended that the Centers for Disease Control and Prevention should disseminate evidence-based HIV prevention interventions (EBIs) to be implemented by health departments, community-based organizations, drug treatment centers, and clinics. Based on these recommendations, the Diffusion of Effective Behavioral Interventions Project was initiated in 2000 and began disseminating interventions into public health practice. For 15 years, the Centers for Disease Control and Prevention has disseminated 29 EBIs to more than 11,300 agencies. Lessons were identified during the 15 years of implementation regarding successful methods of dissemination of EBIs. Lessons around selecting interventions for dissemination, developing a dissemination infrastructure including a resource website (https://effectiveinterventions.cdc.gov), and engagement with stakeholders are discussed. A continuous development approach ensured that intervention implementation materials, instructions, and technical assistance were all tailored to the needs of end users, focus populations, and agency capacities. Six follow-up studies demonstrated that adopters of EBIs were able to obtain comparable outcomes to those of the original efficacy research. The Diffusion of Effective Behavioral Interventions Project may offer guidance for other large, national, evidence-based public health dissemination projects. Published by Elsevier Inc.
Hicks, Taylor B; Shahidullah, Jeffrey D; Carlson, John S; Palejwala, Mohammed H
2014-12-01
The purpose of this study was to empirically investigate Nationally Certified School Psychologists' (NCSP) training in and use of evidence-based interventions (EBIs) for child behavior concerns as well as their reported implementation barriers. A modified Tailored Design Method (TDM; Dillman, Smyth, & Christian, 2009) using up to four mail-based participant contacts was used to obtain survey data (72% usable response rate; n = 392) from a randomly selected national sample of 548 currently practicing NCSPs. Lack of time was rated as the most serious barrier to behavioral EBI implementation, followed by a lack of necessary resources, and financial constraints. Nearly three-quarters (71%) of respondents reported a perceived inadequacy of graduate program training in behavioral EBIs, with a statistically significant difference found between respondents who attended American Psychological Association (APA)-accredited/National Association of School Psychologists (NASP)-approved programs and those who did not. These findings highlight the significant barriers school psychologists encounter when attempting to implement behavioral EBIs within applied practice, as well as the importance of graduate program training in implementation science. Implications for training, practice, and research are discussed. PsycINFO Database Record (c) 2014 APA, all rights reserved.
The CARIBU EBIS control and synchronization system
NASA Astrophysics Data System (ADS)
Dickerson, Clayton; Peters, Christopher
2015-01-01
The Californium Rare Isotope Breeder Upgrade (CARIBU) Electron Beam Ion Source (EBIS) charge breeder has been built and tested. The bases of the CARIBU EBIS electrical system are four voltage platforms on which both DC and pulsed high voltage outputs are controlled. The high voltage output pulses are created with either a combination of a function generator and a high voltage amplifier, or two high voltage DC power supplies and a high voltage solid state switch. Proper synchronization of the pulsed voltages, fundamental to optimizing the charge breeding performance, is achieved with triggering from a digital delay pulse generator. The control system is based on National Instruments realtime controllers and LabVIEW software implementing Functional Global Variables (FGV) to store and access instrument parameters. Fiber optic converters enable network communication and triggering across the platforms.
Preliminary study of injection transients in the TPS storage ring
NASA Astrophysics Data System (ADS)
Chen, C. H.; Liu, Y. C.; Y Chen, J.; Chiu, M. S.; Tseng, F. H.; Fann, S.; Liang, C. C.; Huang, C. S.; Y Lee, T.; Y Chen, B.; Tsai, H. J.; Luo, G. H.; Kuo, C. C.
2017-07-01
An optimized injection efficiency is related to a perfect match between the pulsed magnetic fields in the storage ring and transfer line extraction in the TPS. However, misalignment errors, hardware output errors and leakage fields are unavoidable. We study the influence of injection transients on the stored TPS beam and discuss solutions to compensate these. Related simulations and measurements will be presented.
Vacuum system for room temperature X-ray lithography source (XLS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuchman, J.C.
1988-09-30
A prototype room-temperature X-Ray Lithography Source (XLS)was proposed to be built at Brookhaven National Laboratory as part of a technology-transfer- to-American-industry program. The overall machine comprises a full energy linac, a 170 meter long transport line, and a 39 meter circumference storage ring. The scope of this paper will be limited to describing the storage ring vacuum system. (AIP)
Vacuum system for room temperature X-ray lithography source (XLS)
NASA Astrophysics Data System (ADS)
Schuchman, J. C.
1988-09-01
A prototype room-temperature X-Ray Lithography Source (XLS)was proposed to be built at Brookhaven National Laboratory as part of a technology-transfer- to-American-industry program. The overall machine comprises a full energy linac, a 170 meter long transport line, and a 39 meter circumference storage ring. The scope of this paper will be limited to describing the storage ring vacuum system. (AIP)
Generalized Stability Conditions for an Ultra-Low Energy Electrostatic Charged Particle Storage Ring
NASA Astrophysics Data System (ADS)
Sullivan, Michael
A low energy (~50 eV) electrostatic storage ring has been constructed that can store a recirculating bunch of either electrons or ions. The charged particle bunch 'orbits' within an apparatus consisting of four lenses and two hemispherical deflector analysers, arranged in a 'race-track' configuration of length 64.1 cm. A theoretical study, using transfer matrices from charged particle optics for a 'symmetric' configuration of lens potentials, has been previously completed by Hammond et al. [New J. Phys. 11 (2009) 043033]. That approach was capable of predicting modes of storage which appeared as a resonant-like pattern. An 'asymmetric' configuration, new in this work and extending the previous study to apply to a more general case, has been completed and will be presented alongside experimental results. The level of agreement between the theoretical and experimental results is found to be excellent, and the robustness of the matrix formalism has eliminated the need to rely on computer simulation to achieve storage. This asymmetric arrangement of the lenses allows for greater flexibility in the operation of the ring, creating the potential for a more diverse range of applications and potentially aid in the design of future rings. Several spectra for both electrons and positive ions are presented to provide an indication as to how the charged particle bunch evolves as more orbits are completed. The number of counts inevitably decreases as a function of orbit number due to loss mechanisms. Enhanced measurement techniques, as well as the matrix theory, have made storage of the bunch for over a hundred orbits routine, corresponding to over 65 m travelled, and this is observed directly from the spectra. The application of the storage ring as a multi-pass time-of-flight mass spectrometer has been studied. The isotopes of krypton and xenon have been made to completely separate from one another out of a single pulse of ions. This is observed to occur after ~15 orbits of the ring, roughly 10 m of distance. Initial results have indicated that the mass resolution is approximately 5000. Limitations and potential improvements to the mass resolution are presented.
Measurement of Systematic Error Effects for a Sensitive Storage Ring EDM Polarimeter
NASA Astrophysics Data System (ADS)
Imig, Astrid; Stephenson, Edward
2009-10-01
The Storage Ring EDM Collaboration was using the Cooler Synchrotron (COSY) and the EDDA detector at the Forschungszentrum J"ulich to explore systematic errors in very sensitive storage-ring polarization measurements. Polarized deuterons of 235 MeV were used. The analyzer target was a block of 17 mm thick carbon placed close to the beam so that white noise applied to upstream electrostatic plates increases the vertical phase space of the beam, allowing deuterons to strike the front face of the block. For a detector acceptance that covers laboratory angles larger than 9 ^o, the efficiency for particles to scatter into the polarimeter detectors was about 0.1% (all directions) and the vector analyzing power was about 0.2. Measurements were made of the sensitivity of the polarization measurement to beam position and angle. Both vector and tensor asymmetries were measured using beams with both vector and tensor polarization. Effects were seen that depend upon both the beam geometry and the data rate in the detectors.
Feasibility of a ring FEL at low emittance storage rings
NASA Astrophysics Data System (ADS)
Agapov, I.
2015-09-01
A scheme for generating coherent radiation at latest generation low emittance storage rings such as PETRA III at DESY (Balewski et al., 2004 [1]) is proposed. The scheme is based on focusing and subsequent defocusing of the electron beam in the longitudinal phase space at the undulator location. The expected performance characteristics are estimated for radiation in the wavelength range of 500-1500 eV. It is shown that the average brightness is increased by several orders of magnitude compared to spontaneous undulator radiation, which can open new perspectives for photon-hungry soft X-ray spectroscopy techniques.
PEGASYS: A proposed internal target-spectrometer facility for the PEP storage ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Bibber, K.
A proposal for an internal gas-jet target and forward spectrometer for the PEP storage ring is described. The beam structure, allowable luminosity (L=10/sup 33/ cm/sup /minus/2/s/sup /minus/1/ for H/sub 2/, D/sub 2/ decreasing as Z/sup /minus/1.75/ for nuclear targets) and energy (E/sub e/less than or equal to 15 GeV) make the ring ideal for multiparticle coincidence studies in the scaling regime, and where perturbative QCD may be an apt description of some exclusive and semi-inclusive reactions. 17 refs., 5 figs.
Future Synchrotron Light Sources Based on Ultimate Storage Rings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai, Yunhai; /SLAC
2012-04-09
The main purpose of this talk is to describe how far one might push the state of the art in storage ring design. The talk will start with an overview of the latest developments and advances in the design of synchrotron light sources based on the concept of an 'ultimate' storage ring. The review will establish how bright a ring based light source might be, where the frontier of technological challenges are, and what the limits of accelerator physics are. Emphasis will be given to possible improvements in accelerator design and developments in technology toward the goal of achieving anmore » ultimate storage ring. An ultimate storage ring (USR), defined as an electron ring-based light source having an emittance in both transverse planes at the diffraction limit for the range of X-ray wavelengths of interest for a scientific community, would provide very high brightness photons having high transverse coherence that would extend the capabilities of X-ray imaging and probe techniques beyond today's performance. It would be a cost-effective, high-coherence 4th generation light source, competitive with one based on energy recovery linac (ERL) technology, serving a large number of users studying material, chemical, and biological sciences. Furthermore, because of the experience accumulated over many decades of ring operation, it would have the great advantage of stability and reliability. In this paper we consider the design of an USR having 10-pm-rad emittance. It is a tremendous challenge to design a storage ring having such an extremely low emittance, a factor of 100 smaller than those in existing light sources, especially such that it has adequate dynamic aperture and beam lifetime. In many ultra-low emittance designs, the injection acceptances are not large enough for accumulation of the electron beam, necessitating on-axis injection where stored electron bunches are completely replaced with newly injected ones. Recently, starting with the MAX-IV 7-bend achromatic cell, we have made significant progress with the design of PEP-X, a USR that would inhabit the decommissioned PEP-II tunnel at SLAC. The enlargement of the dynamic aperture is largely a result of the cancellations of the 4th-order resonances in the 3rd-order achromats and the effective use of lattice optimization programs. In this paper, we will show those cancellations of the 4th-order resonances using an analytical approach based on the exponential Lie operators and the Poisson brackets. Wherever possible, our analytical results will be compared with their numerical counterparts. Using the derived formulae, we will construct 4th-order geometric achromats and use them as modules for the lattice of the PEP-X USR, noting that only geometric terms are canceled to the 4th order.« less
Bendtsen, Preben; Müssener, Ulrika; Karlsson, Nadine; López-Pelayo, Hugo; Palacio-Vieira, Jorge; Colom, Joan; Gual, Antoni; Reynolds, Jillian; Wallace, Paul; Segura, Lidia; Anderson, Peter
2016-06-16
The objective of the present study was to explore whether the possibility of offering facilitated access to an alcohol electronic brief intervention (eBI) instead of delivering brief face-to-face advice increased the proportion of consulting adults who were screened and given brief advice. The study was a 12-week implementation study. Sixty primary healthcare units (PHCUs) in 5 jurisdictions (Catalonia, England, the Netherlands, Poland and Sweden) were asked to screen adults who attended the PHCU for risky drinking. A total of 120 primary healthcare centres from 5 jurisdictions in Europe. 746 individual providers (general practitioners, nurses or other professionals) participated in the study. Change in the proportion of patients screened and referred to eBI comparing a baseline 4-week preimplementation period with a 12-week implementation period. The possibility of referring patients to the eBI was not found to be associated with any increase in the proportion of patients screened. However, it was associated with an increase in the proportion of screen-positive patients receiving brief advice from 70% to 80% for the screen-positive sample as a whole (p<0.05), mainly driven by a significant increase in brief intervention rates in England from 87% to 96% (p<0.01). The study indicated that staff displayed a low level of engagement in this new technology. Staff continued to offer face-to-face advice to a larger proportion of patients (54%) than referral to eBI (38%). In addition, low engagement was seen among the referred patients; on average, 18% of the patients logged on to the website with a mean log-on rate across the different countries between 0.58% and 36.95%. Referral to eBI takes nearly as much time as brief oral advice and might require more introduction and training before staff are comfortable with referring to eBI. NCT01501552; Post-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mcwilliams, A. J.; Daugherty, W. L.; Skidmore, T. E.
The 9975 Type B shipping package is used within the DOE complex for shipping special nuclear materials. This package is re-certified annually in accordance with Safety Analysis Report for Packaging (SARP) requirements. The package is also used at the Savannah River Site as part of the long-term storage configuration of special nuclear materials. As such, the packages do not undergo annual recertification during storage, with uncertainty as to how long some of the package components will meet their functional requirements in the storage environment. The packages are currently approved for up to 15 years storage, and work continues to providemore » a technical basis to extend that period. This report describes efforts by the Savannah River National Laboratory (SRNL) to extend the service life estimate of Viton® GLT and GLT-S fluoroelastomer O-rings used in the 9975 shipping package. O-rings of both GLT and GLT-S compositions are undergoing accelerated aging at elevated temperature, and are periodically tested for compression stress relaxation (CSR) behavior. The CSR behavior of O-rings was evaluated at temperatures from 175 to 400 °F. These collective data were used to develop predictive models for extrapolation of CSR behavior to relevant service temperatures (< 156 °F). The predictive model developed from the CSR data conservatively indicates a service life of approximately 37 years for Viton GLT O-rings at the maximum effective service temperature of 156 °F. The estimated service life for Viton GLT-S O-rings is significantly longer.« less
The KACST Heavy-Ion Electrostatic Storage Ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Almuqhim, A. A.; Alshammari, S. M.; El Ghazaly, M. O. A.
2011-10-27
A novel Electrostatic Storage Ring (ESR) for beams at energies up to 30keV/q is now being constructed at the National Centre for Mathematics and Physics (NCMP), King Abdul-Aziz City for Science and Technology (KACST). The ring is designed to be the core of a highly flexible experimental platform that will combine a large package of complementary beam techniques for atomic and molecular physics and related fields. The lattice design had to cover the different experimental techniques that the ring will be equipped with, such as e.g. Electron-Ion, Laser-Ion, Ion-Ion or Ion-Neutral beams, in both crossed and merged-beam configurations. The developmentmore » of such an ESR is realized in a staged approach, in which a simple and early-run adaptation of the ring is built first, and then this basic version is upgraded to a higher symmetry of the ultimate version of the ring. Here, we report a general overview of this technical development with a focus on the layout of the first built stage of the ring.« less
NASA Astrophysics Data System (ADS)
Paris, Elizabeth
The ``November Revolution'' of 1974 and the experiments that followed consolidated the place of the Standard Model in modern particle physics. Much of the evidence on which these conclusions depended was generated by a new type of tool: colliding beam storage rings, which had been considered physically unfeasible twenty years earlier. In 1956 a young experimentalist named Gerry O'Neill dedicated himself to demonstrating that such an apparatus could do useful physics. The storage ring movement encountered numerous obstacles before generating one of the standard machines for high energy research. In fact, it wasn't until 1970 that the U.S. finally broke ground on its first electron-positron collider. Drawing extensively on archival sources and supplementing them with the personal accounts of many of the individuals who took part, Ringing in the New Physics examines this instance of post-World War II techno-science and the new social, political and scientific tensions that characterize it. The motivations are twofold: first, that the chronicle of storage rings may take its place beside mathematical group theory, computer simulations, magnetic spark chambers, and the like as an important contributor to a view of matter and energy which has been the dominant model for the last twenty-five years. In addition, the account provides a case study for the integration of the personal, professional, institutional, and material worlds when examining an episode in the history or sociology of twentieth century science. The story behind the technological development of storage rings holds fascinating insights into the relationship between theory and experiment, collaboration and competition in the physics community, the way scientists obtain funding and their responsibilities to it, and the very nature of what constitutes ``successful'' science in the post- World War II era.
Locke, Jill; Beidas, Rinad S; Marcus, Steven; Stahmer, Aubyn; Aarons, Gregory A; Lyon, Aaron R; Cannuscio, Carolyn; Barg, Frances; Dorsey, Shannon; Mandell, David S
2016-10-10
The significant lifelong impairments associated with autism spectrum disorder (ASD), combined with the growing number of children diagnosed with ASD, have created urgency in improving school-based quality of care. Although many interventions have shown efficacy in university-based research, few have been effectively implemented and sustained in schools, the primary setting in which children with ASD receive services. Individual- and organizational-level factors have been shown to predict the implementation of evidence-based interventions (EBIs) for the prevention and treatment of other mental disorders in schools, and may be potential targets for implementation strategies in the successful use of autism EBIs in schools. The purpose of this study is to examine the individual- and organizational-level factors associated with the implementation of EBIs for children with ASD in public schools. We will apply the Domitrovich and colleagues (2008) framework that examines the influence of contextual factors (i.e., individual- and organizational-level factors) on intervention implementation in schools. We utilize mixed methods to quantitatively test whether the factors identified in the Domitrovich and colleagues (2008) framework are associated with the implementation of autism EBIs, and use qualitative methods to provide a more comprehensive understanding of the factors associated with successful implementation and sustainment of these interventions with the goal of tailoring implementation strategies. The results of this study will provide an in-depth understanding of individual- and organizational-level factors that influence the successful implementation of EBIs for children with ASD in public schools. These data will inform potential implementation targets and tailoring of strategies that will help schools overcome barriers to implementation and ultimately improve the services and outcomes for children with ASD.
EBI1/CCR7 is a new member of dendritic cell chemokine receptor that is up-regulated upon maturation.
Yanagihara, S; Komura, E; Nagafune, J; Watarai, H; Yamaguchi, Y
1998-09-15
Dendritic cells (DC) that are stimulated with inflammatory mediators can maturate and migrate from nonlymphoid tissues to lymphoid organs to initiate T cell-mediated immune responses. This migratory step is closely related to the maturation of the DC. In an attempt to identify chemokine receptors that might influence migration and are selectively expressed in mature DC, we have discovered that the chemokine receptor, EBI1/CCR7, is strikingly up-regulated upon maturation in three distinct culture systems: 1) mouse bone marrow-derived DC, 2) mouse epidermal Langerhans cells, and 3) human monocyte-derived DC. The EBI1/CCR7 expressed in mature DC is functional because ELC/MIP-3beta, recently identified as a ligand of EBI1/CCR7, induces a rise in intracellular free calcium concentrations and directional migration of human monocyte-derived mature DC (HLA-DRhigh, CD1a(low), CD14-, CD25+, CD83+, and CD86high) in a dose-dependent manner, but not of immature DC (HLA-DRlow, CD1a(high), CD14-, CD25-, CD83-, and CD86-). In contrast, macrophage inflammatory protein-1alpha (MIP-1alpha), monocyte chemotactic protein-3 (MCP-3), and RANTES are active on immature DC but not on mature DC. Thus, it seems likely that MIP-1alpha, MCP-3, and RANTES can mediate the migration of immature DC located in peripheral sites, whereas ELC/MIP-3beta can direct the migration of Ag-carrying DC from peripheral inflammatory sites, where DC are stimulated to up-regulate the expression of EBI1/CCR7, to lymphoid organs. It is postulated that different chemokines and chemokine receptors are involved in DC migration in vivo, depending on the maturation state of DC.
Wearable Vector Electrical Bioimpedance System to Assess Knee Joint Health
Hersek, Sinan; Töreyin, Hakan; Teague, Caitlin N.; Millard-Stafford, Mindy L.; Jeong, Hyeon-Ki; Bavare, Miheer M.; Wolkoff, Paul; Sawka, Michael N.; Inan, Omer T.
2017-01-01
Objective We designed and validated a portable electrical bioimpedance (EBI) system to quantify knee joint health. Methods Five separate experiments were performed to demonstrate the: (1) ability of the EBI system to assess knee injury and recovery; (2) inter-day variability of knee EBI measurements; (3) sensitivity of the system to small changes in interstitial fluid volume; (4) reducing the error of EBI measurements using acceleration signals; (5) use of the system with dry electrodes integrated to a wearable knee wrap. Results (1) The absolute difference in resistance (R) and reactance (X) from the left to the right knee was able to distinguish injured and healthy knees (p<0.05); the absolute difference in R decreased significantly (p<0.05) in injured subjects following rehabilitation. (2) The average inter-day variability (standard deviation) of the absolute difference in knee R was 2.5Ω, and for X was, 1.2 Ω. (3) Local heating/cooling resulted in a significant decrease/increase in knee R (p<0.01). (4) The proposed subject position detection algorithm achieved 97.4% leave-one subject out cross-validated accuracy and 98.2% precision in detecting when the subject is in the correct position to take measurements. (5) Linear regression between the knee R and X measured using the wet electrodes and the designed wearable knee wrap were highly correlated (r2 = 0.8 and 0.9, respectively). Conclusion This work demonstrates the use of wearable EBI measurements in monitoring knee joint health. Significance The proposed wearable system has the potential for assessing knee joint health outside the clinic/lab and help guide rehabilitation. PMID:28026745
Wearable Vector Electrical Bioimpedance System to Assess Knee Joint Health.
Hersek, Sinan; Toreyin, Hakan; Teague, Caitlin N; Millard-Stafford, Mindy L; Jeong, Hyeon-Ki; Bavare, Miheer M; Wolkoff, Paul; Sawka, Michael N; Inan, Omer T
2017-10-01
We designed and validated a portable electrical bioimpedance (EBI) system to quantify knee joint health. Five separate experiments were performed to demonstrate the: 1) ability of the EBI system to assess knee injury and recovery; 2) interday variability of knee EBI measurements; 3) sensitivity of the system to small changes in interstitial fluid volume; 4) reducing the error of EBI measurements using acceleration signals; and 5) use of the system with dry electrodes integrated to a wearable knee wrap. 1) The absolute difference in resistance ( R) and reactance (X) from the left to the right knee was able to distinguish injured and healthy knees (p < 0.05); the absolute difference in R decreased significantly (p < 0.05) in injured subjects following rehabilitation. 2) The average interday variability (standard deviation) of the absolute difference in knee R was 2.5 Ω and for X was 1.2 Ω. 3) Local heating/cooling resulted in a significant decrease/increase in knee R (p < 0.01). 4) The proposed subject position detection algorithm achieved 97.4% leave-one subject out cross-validated accuracy and 98.2% precision in detecting when the subject is in the correct position to take measurements. 5) Linear regression between the knee R and X measured using the wet electrodes and the designed wearable knee wrap were highly correlated ( R 2 = 0.8 and 0.9, respectively). This study demonstrates the use of wearable EBI measurements in monitoring knee joint health. The proposed wearable system has the potential for assessing knee joint health outside the clinic/lab and help guide rehabilitation.
Experimental Evidence for the Los Alamos Proton Storage Ring Beam Instability
NASA Astrophysics Data System (ADS)
Plum, M.; Fitzgerald, D. H.; Macek, R.; Sander, O.; Thiessen, H. A.; Wang, T. S.; Wilkinson, C.
1997-05-01
Although the exact instability mechanism at the Proton Storage Ring (PSR) has not yet been conclusively identified, the evidence gathered to date is consistent with an e-p instability. We have recently acquired new data which shows that clearing electrodes significantly affect the instability threshold. A set of comprehensive measurements is also planned for the first months of 1997. In this paper we will present our latest data.
Fundamentals of Coherent Synchrotron Radiation in Storage Rings
NASA Astrophysics Data System (ADS)
Sannibale, F.; Byrd, J. M.; Loftsdottir, A.; Martin, M. C.; Venturini, M.
2004-05-01
We present the fundamental concepts for producing stable broadband coherent synchrotron radiation (CSR) in the terahertz frequency region in an electron storage ring. The analysis includes distortion of bunch shape from the synchrotron radiation (SR), enhancing higher frequency coherent emission and limits to stable emission due to a microbunching instability excited by the SR. We use these concepts to optimize the performance of a source for CSR emission.
Something old, something new: Why models need a multi-pool representation of storage reserves
NASA Astrophysics Data System (ADS)
Richardson, Andrew; Carbone, Mariah
2015-04-01
We know surprisingly little about processes regulating the allocation of photosynthetic assimilates to growth, storage, and other metabolic functions. Storage of nonstructural carbon (NSC, principally sugars and starch) is critically important for woody plants, because these reserves enable sessile, long-lived organisms to tolerate biotic and abiotic stress, including pests, disturbance, and drought. But, critical questions about the size and turnover of these reserves remain unanswered. Labeling studies have generally shown rapid use of new (labeled) NSC and inferred fast mixing between old and new NSC, both of which suggest quick turnover of storage reserves. However, recent studies have shown that some of the reserves stored in stem and root tissue are not only a decade old, but also still available to support new tissue growth following catastrophic disturbance. We characterized the distribution of NSC in the stemwood, branches, and roots of two temperate trees, and we used the continuous label offered by the radiocarbon (14C) bomb spike to estimate the mean age of NSC in different tissues of two temperate trees. NSC in branches and outermost stemwood growth rings had the 14C signature of the current growing season. However, NSC in older above- and below-ground tissues was enriched in 14C, indicating that it was produced from older assimilates. Radial patterns of 14C in stemwood NSC showed strong mixing of NSC across the youngest growth rings, with limited "mixing in" of younger NSC to older rings. Sugars in the outermost 5 growth rings, accounting for two-thirds of the stemwood pool, had a mean age < 1 y, whereas sugars in older growth rings had a mean age > 5 y. Thus, there is not a single, well-mixed "storage pool," and indeed "young" and "old" storage compounds appear to be physically isolated from each other. We will discuss the implications of these results for improving model representation of NSC storage and consumption by forest trees. We will suggest that there are conceptual similarities between modeling NSC pools and modeling soil C pools. We will propose future directions for modeling NSCs and also identify key questions that still need to be answered with new experimental work.
The CARIBU EBIS control and synchronization system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dickerson, Clayton, E-mail: cdickerson@anl.gov; Peters, Christopher, E-mail: cdickerson@anl.gov
2015-01-09
The Californium Rare Isotope Breeder Upgrade (CARIBU) Electron Beam Ion Source (EBIS) charge breeder has been built and tested. The bases of the CARIBU EBIS electrical system are four voltage platforms on which both DC and pulsed high voltage outputs are controlled. The high voltage output pulses are created with either a combination of a function generator and a high voltage amplifier, or two high voltage DC power supplies and a high voltage solid state switch. Proper synchronization of the pulsed voltages, fundamental to optimizing the charge breeding performance, is achieved with triggering from a digital delay pulse generator. Themore » control system is based on National Instruments realtime controllers and LabVIEW software implementing Functional Global Variables (FGV) to store and access instrument parameters. Fiber optic converters enable network communication and triggering across the platforms.« less
Analysis Tool Web Services from the EMBL-EBI.
McWilliam, Hamish; Li, Weizhong; Uludag, Mahmut; Squizzato, Silvano; Park, Young Mi; Buso, Nicola; Cowley, Andrew Peter; Lopez, Rodrigo
2013-07-01
Since 2004 the European Bioinformatics Institute (EMBL-EBI) has provided access to a wide range of databases and analysis tools via Web Services interfaces. This comprises services to search across the databases available from the EMBL-EBI and to explore the network of cross-references present in the data (e.g. EB-eye), services to retrieve entry data in various data formats and to access the data in specific fields (e.g. dbfetch), and analysis tool services, for example, sequence similarity search (e.g. FASTA and NCBI BLAST), multiple sequence alignment (e.g. Clustal Omega and MUSCLE), pairwise sequence alignment and protein functional analysis (e.g. InterProScan and Phobius). The REST/SOAP Web Services (http://www.ebi.ac.uk/Tools/webservices/) interfaces to these databases and tools allow their integration into other tools, applications, web sites, pipeline processes and analytical workflows. To get users started using the Web Services, sample clients are provided covering a range of programming languages and popular Web Service tool kits, and a brief guide to Web Services technologies, including a set of tutorials, is available for those wishing to learn more and develop their own clients. Users of the Web Services are informed of improvements and updates via a range of methods.
Analysis Tool Web Services from the EMBL-EBI
McWilliam, Hamish; Li, Weizhong; Uludag, Mahmut; Squizzato, Silvano; Park, Young Mi; Buso, Nicola; Cowley, Andrew Peter; Lopez, Rodrigo
2013-01-01
Since 2004 the European Bioinformatics Institute (EMBL-EBI) has provided access to a wide range of databases and analysis tools via Web Services interfaces. This comprises services to search across the databases available from the EMBL-EBI and to explore the network of cross-references present in the data (e.g. EB-eye), services to retrieve entry data in various data formats and to access the data in specific fields (e.g. dbfetch), and analysis tool services, for example, sequence similarity search (e.g. FASTA and NCBI BLAST), multiple sequence alignment (e.g. Clustal Omega and MUSCLE), pairwise sequence alignment and protein functional analysis (e.g. InterProScan and Phobius). The REST/SOAP Web Services (http://www.ebi.ac.uk/Tools/webservices/) interfaces to these databases and tools allow their integration into other tools, applications, web sites, pipeline processes and analytical workflows. To get users started using the Web Services, sample clients are provided covering a range of programming languages and popular Web Service tool kits, and a brief guide to Web Services technologies, including a set of tutorials, is available for those wishing to learn more and develop their own clients. Users of the Web Services are informed of improvements and updates via a range of methods. PMID:23671338
Possible Role of Inflammation and Galectin-3 in Brain Injury after Subarachnoid Hemorrhage
2018-01-01
Aneurysmal subarachnoid hemorrhage (SAH) is known as one of the most devastating diseases in the central nervous system. In the past few decades, research on SAH has focused on cerebral vasospasm to prevent post-SAH delayed cerebral ischemia (DCI) and to improve outcomes. However, increasing evidence has suggested that early brain injury (EBI) is an important mechanism contributing to DCI, cerebral vasospasm as well as poor outcomes. Though the mechanism of EBI is very complex, inflammation is thought to play a pivotal role in EBI. Galectin-3 is a unique chimera type in the galectin family characterized by its β-galactoside-binding lectin, which mediates various pathologies, such as fibrosis, cell adhesion, and inflammation. Recently, two clinical studies revealed galectin-3 to be a possible prognostic biomarker in SAH patients. In addition, our recent report suggested that higher acute-stage plasma galectin-3 levels correlated with subsequent development of delayed cerebral infarction that was not associated with vasospasm in SAH patients. We review the possible role and molecular mechanisms of inflammation as well as galectin-3 in brain injuries, especially focusing on EBI after SAH, and discuss galectin-3 as a potential new therapeutic or research target in post-SAH brain injuries. PMID:29414883
Hao, Shuangying; Song, Chuanhui; Shang, Longcheng; Yu, Jiang; Qiao, Tong; Li, Kuanyu
2016-03-10
Previous studies have demonstrated that activation of Akt may alleviate early brain injury (EBI) following subarachnoid hemorrhage (SAH). This study is undertaken to determine whether iron metabolism is involved in the beneficial effect of Akt activation after SAH. Therefore, we used a novel molecule, SC79, to activate Akt in an experimental Sprague-Dawley rat model of SAH. Rats were randomly divided into four groups as follows: sham, SAH, SAH + vehicle, SAH + SC79. The results confirmed that SC79 effectively enhanced the defense against oxidative stress and alleviated EBI in the temporal lobe after SAH. Interestingly, we found that phosphorylation of Akt by SC79 reduced cell surface transferrin receptor-mediated iron uptake and promoted ferroportin-mediated iron transport after SAH. As a result, SC79 administration diminished the iron content in the brain tissue. Moreover, the impaired Fe-S cluster biogenesis was recovered and loss of the activities of the Fe-S cluster-containing enzymes were regained, indicating that injured mitochondrial functions are restored to healthy levels. These findings suggest that disrupted iron homeostasis could contribute to EBI and Akt activation may regulate iron metabolism to relieve iron toxicity, further protecting neurons from EBI after SAH.
The Potential-Well Distortion Effect and Coherent Instabilities of Electron Bunches in Storage Rings
NASA Astrophysics Data System (ADS)
Korchuganov, V. N.; Smygacheva, A. S.; Fomin, E. A.
2018-05-01
The effect of electromagnetic interaction between electron bunches and the vacuum chamber of a storage ring on the longitudinal motion of bunches is studied. Specifically, the potential-well distortion effect and the so-called coherent instabilities of coupled bunches are considered. An approximate analytical solution for the frequencies of incoherent oscillations of bunches distributed arbitrarily within the ring is obtained for a distorted potential well. A new approach to determining frequencies of coherent oscillations and an approximate analytical relation for estimating the stability of a system of bunches as a function of their distribution in the accelerator orbit are presented.
The conversion of CESR to operate as the Test Accelerator, CesrTA. Part 1: overview
NASA Astrophysics Data System (ADS)
Billing, M. G.
2015-07-01
Cornell's electron/positron storage ring (CESR) was modified over a series of accelerator shutdowns beginning in May 2008, which substantially improves its capability for research and development for particle accelerators. CESR's energy span from 1.8 to 5.6 GeV with both electrons and positrons makes it ideal for the study of a wide spectrum of accelerator physics issues and instrumentation related to present light sources and future lepton damping rings. Additionally a number of these are also relevant for the beam physics of proton accelerators. This paper outlines the motivation, design and conversion of CESR to a test accelerator, CESRTA, enhanced to study such subjects as low emittance tuning methods, electron cloud (EC) effects, intra-beam scattering, fast ion instabilities as well as general improvements to beam instrumentation. While the initial studies of CESRTA focussed on questions related to the International Linear Collider (ILC) damping ring design, CESRTA is a very flexible storage ring, capable of studying a wide range of accelerator physics and instrumentation questions. This paper contains the outline and the basis for a set of papers documenting the reconfiguration of the storage ring and the associated instrumentation required for the studies described above. Further details may be found in these papers.
NASA Astrophysics Data System (ADS)
Ishikawa, Shigeru; Nemoto, Tetsushi; Yamabe, Tokio
2018-06-01
Hydrogen storage in a truncated triangular pyramid molecule C33H21N3, which consists of three pyridine rings and one benzene ring bridged by six vinylene groups, is studied by quantum chemical methods. The molecule is derived by substituting three benzene rings in a truncated tetrahedron hydrocarbon C36H24 with pyridine rings. The optimized molecular structure under C 3v symmetry shows no imaginary vibrational modes at the B3LYP/cc-pVTZ level of theory. The hydrogen storage process is investigated based on the MP2/cc-pVTZ method. Like the structure before substitution, the C33H21N3 molecule has a cavity that stores a hydrogen molecule with a binding energy of - 140 meV. The Langmuir isotherm shows that this cavity can store hydrogen at higher temperatures and lower pressures than usual physisorption materials. The C33H21N3 molecule has a kinetic advantage over the C36H24 molecule because the former molecule has a lower barrier (+ 560 meV) for the hydrogen molecule entering the cavity compared with the latter molecule (+ 730 meV) owing to the lack of hydrogen atoms narrowing the opening.
Electron-cloud updated simulation results for the PSR, and recent results for the SNS
NASA Astrophysics Data System (ADS)
Pivi, M.; Furman, M. A.
2002-05-01
Recent simulation results for the main features of the electron cloud in the storage ring of the Spallation Neutron Source (SNS) at Oak Ridge, and updated results for the Proton Storage Ring (PSR) at Los Alamos are presented in this paper. A refined model for the secondary emission process including the so called true secondary, rediffused and backscattered electrons has recently been included in the electron-cloud code.
BPM Breakdown Potential in the PEP-II B-factory Storage Ring Collider
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weathersby, Stephen; Novokhatski, Alexander; /SLAC
2010-02-10
High current B-Factory BPM designs incorporate a button type electrode which introduces a small gap between the button and the beam chamber. For achievable currents and bunch lengths, simulations indicate that electric potentials can be induced in this gap which are comparable to the breakdown voltage. This study characterizes beam induced voltages in the existing PEP-II storage ring collider BPM as a function of bunch length and beam current.
Multi-objective dynamic aperture optimization for storage rings
Li, Yongjun; Yang, Lingyun
2016-11-30
We report an efficient dynamic aperture (DA) optimization approach using multiobjective genetic algorithm (MOGA), which is driven by nonlinear driving terms computation. It was found that having small low order driving terms is a necessary but insufficient condition of having a decent DA. Then direct DA tracking simulation is implemented among the last generation candidates to select the best solutions. The approach was demonstrated successfully in optimizing NSLS-II storage ring DA.
Towards a 4{sup th} generation storage ring at the Canadian Light Source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dallin, Les; Wurtz, Ward
2016-07-27
Demands from beamline scientists for more brilliant sources of synchrotron radiation have resulted in the emergence of 4{sup th} generation (diffraction-limited) storage rings. The practical development of the multi-bend achromat (MBA) concept by MAX IV lab has spurred many synchrotron light sources around the world to develop similar machines. For existing facilities two options are available: upgrading existing machines or building a new structure. The Canadian Light Source (CLS) has explored both options. For a new low emittance source in the existing CLS tunnel a decrease in electron energy would be required. A machine similar to the ALS upgrade couldmore » be contemplated. To achieve low emittance at our present energy of 2.9 GeV a new storage ring is desirable. Several options have been investigated. These designs use extremely strong focusing magnets to achieve extremely low emittances in compact lattice achromats.« less
Preparing the MAX IV storage rings for timing-based experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stråhlman, C., E-mail: Christian.Strahlman@maxlab.lu.se; Olsson, T., E-mail: Teresia.Olsson@maxlab.lu.se; Leemann, S. C.
2016-07-27
Time-resolved experimental techniques are increasingly abundant at storage ring facilities. Recent developments in accelerator technology and beamline instrumentation allow for simultaneous operation of high-intensity and timing-based experiments. The MAX IV facility is a state-of-the-art synchrotron light source in Lund, Sweden, that will come into operation in 2016. As many storage ring facilities are pursuing upgrade programs employing strong-focusing multibend achromats and passive harmonic cavities (HCs) in high-current operation, it is of broad interest to study the accelerator and instrumentation developments required to enable timing-based experiments at such machines. In particular, the use of hybrid filling modes combined with pulse pickingmore » by resonant excitation or pseudo single bunch has shown promising results. These methods can be combined with novel beamline instrumentation, such as choppers and instrument gating. In this paper we discuss how these techniques can be implemented and employed at MAX IV.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kline, Josh; /SLAC
2006-08-28
The testing of the upgrade prototype for the bunch current monitors (BCMs) in the PEP-II storage rings at the Stanford Linear Accelerator Center (SLAC) is the topic of this paper. Bunch current monitors are used to measure the charge in the electron/positron bunches traveling in particle storage rings. The BCMs in the PEP-II storage rings need to be upgraded because components of the current system have failed and are known to be failure prone with age, and several of the integrated chips are no longer produced making repairs difficult if not impossible. The main upgrade is replacing twelve old (1995)more » field programmable gate arrays (FPGAs) with a single Virtex II FPGA. The prototype was tested using computer synthesis tools, a commercial signal generator, and a fast pulse generator.« less
A compact radiation source for digital subtractive angiography
NASA Astrophysics Data System (ADS)
Wiedemann, H.; Baltay, M.; Carr, R.; Hernandez, M.; Lavender, W.
1994-08-01
Beam requirements for 33 keV radiation used in digital subtraction angiography have been established through extended experimentation first at Stanford and later at the National Synchrotron Light Source in Brookhaven. So far research and development of this medical procedure to image coronary blood vessels have been undertaken on large high energy electron storage rings. With progress in this diagnostic procedure, it is interesting to look for an optimum concept for providing a 33 keV radiation source which would fit into the environment of a hospital. A variety of competing effects and technologies to produce 33 keV radiation are available, but none of these processes provides the combination of sufficient photon flux and monochromaticity except for synchrotron radiation from an electron storage ring. The conceptual design of a compact storage ring optimized to fit into a hospital environment and producing sufficient 33 keV radiation for digital subtraction radiography will be discussed.
de Jonge, Martin D.; Ryan, Christopher G.; Jacobsen, Chris J.
2014-01-01
X-ray nanoprobes require coherent illumination to achieve optic-limited resolution, and so will benefit directly from diffraction-limited storage rings. Here, the example of high-resolution X-ray fluorescence tomography is focused on as one of the most voracious demanders of coherent photons, since the detected signal is only a small fraction of the incident flux. Alternative schemes are considered for beam delivery, sample scanning and detectors. One must consider as well the steps before and after the X-ray experiment: sample preparation and examination conditions, and analysis complexity due to minimum dose requirements and self-absorption. By understanding the requirements and opportunities for nanoscale fluorescence tomography, one gains insight into the R&D challenges in optics and instrumentation needed to fully exploit the source advances that diffraction-limited storage rings offer. PMID:25177992
Collective electron driven linac for high energy physics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seeman, J.T.
1983-08-01
A linac design is presented in which an intense ultrarelativistic electron bunch is used to excite fields in a series of cavities and accelerate charged particles. The intense electron bunch is generated in a simple storage ring to have the required transverse and longitudinal dimensions. The bunch is then transferred to the linac. The linac structure can be inexpensively constructed of spacers and washers. The fields in the cells resulting from the bunch passage are calculated using the program BCI. The results show that certain particles within the driving bunch and also trailing particles of any sign charge can bemore » accelerated. With existing electron storage rings, accelerating gradients greater than 16 MV/m are possible. Examples of two accelerators are given: a 30 GeV electron/positron accelerator useful as an injector for a high energy storage ring and 2) a 110 GeV per beam electron-positron collider.« less
Modeling Systematic Error Effects for a Sensitive Storage Ring EDM Polarimeter
NASA Astrophysics Data System (ADS)
Stephenson, Edward; Imig, Astrid
2009-10-01
The Storage Ring EDM Collaboration has obtained a set of measurements detailing the sensitivity of a storage ring polarimeter for deuterons to small geometrical and rate changes. Various schemes, such as the calculation of the cross ratio [1], can cancel effects due to detector acceptance differences and luminosity differences for states of opposite polarization. Such schemes fail at second-order in the errors, becoming sensitive to geometrical changes, polarization magnitude differences between opposite polarization states, and changes to the detector response with changing data rates. An expansion of the polarimeter response in a Taylor series based on small errors about the polarimeter operating point can parametrize such effects, primarily in terms of the logarithmic derivatives of the cross section and analyzing power. A comparison will be made to measurements obtained with the EDDA detector at COSY-J"ulich. [4pt] [1] G.G. Ohlsen and P.W. Keaton, Jr., NIM 109, 41 (1973).
Symplectic orbit and spin tracking code for all-electric storage rings
NASA Astrophysics Data System (ADS)
Talman, Richard M.; Talman, John D.
2015-07-01
Proposed methods for measuring the electric dipole moment (EDM) of the proton use an intense, polarized proton beam stored in an all-electric storage ring "trap." At the "magic" kinetic energy of 232.792 MeV, proton spins are "frozen," for example always parallel to the instantaneous particle momentum. Energy deviation from the magic value causes in-plane precession of the spin relative to the momentum. Any nonzero EDM value will cause out-of-plane precession—measuring this precession is the basis for the EDM determination. A proposed implementation of this measurement shows that a proton EDM value of 10-29e -cm or greater will produce a statistically significant, measurable precession after multiply repeated runs, assuming small beam depolarization during 1000 s runs, with high enough precision to test models of the early universe developed to account for the present day particle/antiparticle population imbalance. This paper describes an accelerator simulation code, eteapot, a new component of the Unified Accelerator Libraries (ual), to be used for long term tracking of particle orbits and spins in electric bend accelerators, in order to simulate EDM storage ring experiments. Though qualitatively much like magnetic rings, the nonconstant particle velocity in electric rings gives them significantly different properties, especially in weak focusing rings. Like the earlier code teapot (for magnetic ring simulation) this code performs exact tracking in an idealized (approximate) lattice rather than the more conventional approach, which is approximate tracking in a more nearly exact lattice. The Bargmann-Michel-Telegdi (BMT) equation describing the evolution of spin vectors through idealized bend elements is also solved exactly—original to this paper. Furthermore the idealization permits the code to be exactly symplectic (with no artificial "symplectification"). Any residual spurious damping or antidamping is sufficiently small to permit reliable tracking for the long times, such as the 1000 s assumed in estimating the achievable EDM precision. This paper documents in detail the theoretical formulation implemented in eteapot. An accompanying paper describes the practical application of the eteapot code in the Universal Accelerator Libraries (ual) environment to "resurrect," or reverse engineer, the "AGS-analog" all-electric ring built at Brookhaven National Laboratory in 1954. Of the (very few) all-electric rings ever commissioned, the AGS-analog ring is the only relativistic one and is the closest to what is needed for measuring proton (or, even more so, electron) EDM's. The companion paper also describes preliminary lattice studies for the planned proton EDM storage rings as well as testing the code for long time orbit and spin tracking.
Instrumentation for the study of low emittance tuning and beam dynamics at CESR
NASA Astrophysics Data System (ADS)
Billing, M. G.; Dobbins, J. A.; Forster, M. J.; Kreinick, D. L.; Meller, R. E.; Peterson, D. P.; Ramirez, G. A.; Rendina, M. C.; Rider, N. T.; Sagan, D. C.; Shanks, J.; Sikora, J. P.; Stedinger, M. G.; Strohman, C. R.; Williams, H. A.; Palmer, M. A.; Holtzapple, R. L.; Flanagan, J.
2017-11-01
The Cornell Electron-positron Storage Ring (CESR) has been converted from a High Energy Physics electron-positron collider to operate as a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS) and to conduct accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Some of the specific topics that were targeted for the initial phase of operation of the storage ring in this mode for CESR as a Test Accelerator (CesrTA) included 1) tuning techniques to produce low emittance beams, 2) the study of electron cloud development in a storage ring and 3) intra-beam scattering effects. The complete conversion of CESR to CesrTA occurred over a several year period, described elsewhere [1-3]. In addition to instrumentation for the storage ring, which was created for CesrTA, existing instrumentation was modified to facilitate the entire range of investigations to support these studies. Procedures were developed, often requiring coordinated measurements among different instruments [4]. This paper describes the instruments utilized for the study of beam dynamics during the operation of CesrTA. The treatment of these instruments will remain fairly general in this paper as it focusses on an overview of the instruments themselves. Their interaction and inter-relationships during sequences of observations is found in a companion paper describing the associated measurement techniques. More detailed descriptions and detailed operational performance for some of the instrumentation may be found elsewhere and these will be referenced in the related sections of this paper.
Project power: Adapting an evidence-based HIV/STI prevention intervention for incarcerated women.
Fasula, Amy M; Fogel, Catherine I; Gelaude, Deborah; Carry, Monique; Gaiter, Juarlyn; Parker, Sharon
2013-06-01
Incarcerated women are a critical population for targeted HIV/STI prevention programming; however, there is a dearth of evidence-based, genderspecific behavioral interventions for this population. Systematically adapting existing evidence-based interventions (EBIs) can help fill this gap. We illustrate the adaptation of the HIV/STI prevention EBI, Project Safe, for use among incarcerated women and delivery in prisons. Project POWER, the final adapted intervention, was developed using formative research with prison staff and administration, incarcerated and previously incarcerated women, and input of community advisory boards. Intervention delivery adaptations included: shorter, more frequent intervention sessions; booster sessions prior to and just after release; facilitator experience in prisons and counseling; and new videos. Intervention content adaptations addressed issues of empowerment, substance use, gender and power inequity in relationships, interpersonal violence, mental health, reentry, and social support. This illustration of the adaption process provides information to inform additional efforts to adapt EBIs for this underserved population.
Mitchell, Alex; Bucchini, Francois; Cochrane, Guy; Denise, Hubert; Hoopen, Petra ten; Fraser, Matthew; Pesseat, Sebastien; Potter, Simon; Scheremetjew, Maxim; Sterk, Peter; Finn, Robert D.
2016-01-01
EBI metagenomics (https://www.ebi.ac.uk/metagenomics/) is a freely available hub for the analysis and archiving of metagenomic and metatranscriptomic data. Over the last 2 years, the resource has undergone rapid growth, with an increase of over five-fold in the number of processed samples and consequently represents one of the largest resources of analysed shotgun metagenomes. Here, we report the status of the resource in 2016 and give an overview of new developments. In particular, we describe updates to data content, a complete overhaul of the analysis pipeline, streamlining of data presentation via the website and the development of a new web based tool to compare functional analyses of sequence runs within a study. We also highlight two of the higher profile projects that have been analysed using the resource in the last year: the oceanographic projects Ocean Sampling Day and Tara Oceans. PMID:26582919
Capturing spiral radial growth of conifers using the superellipse to model tree-ring geometric shape
Shi, Pei-Jian; Huang, Jian-Guo; Hui, Cang; Grissino-Mayer, Henri D.; Tardif, Jacques C.; Zhai, Li-Hong; Wang, Fu-Sheng; Li, Bai-Lian
2015-01-01
Tree-rings are often assumed to approximate a circular shape when estimating forest productivity and carbon dynamics. However, tree rings are rarely, if ever, circular, thereby possibly resulting in under- or over-estimation in forest productivity and carbon sequestration. Given the crucial role played by tree ring data in assessing forest productivity and carbon storage within a context of global change, it is particularly important that mathematical models adequately render cross-sectional area increment derived from tree rings. We modeled the geometric shape of tree rings using the superellipse equation and checked its validation based on the theoretical simulation and six actual cross sections collected from three conifers. We found that the superellipse better describes the geometric shape of tree rings than the circle commonly used. We showed that a spiral growth trend exists on the radial section over time, which might be closely related to spiral grain along the longitudinal axis. The superellipse generally had higher accuracy than the circle in predicting the basal area increment, resulting in an improved estimate for the basal area. The superellipse may allow better assessing forest productivity and carbon storage in terrestrial forest ecosystems. PMID:26528316
Shi, Pei-Jian; Huang, Jian-Guo; Hui, Cang; Grissino-Mayer, Henri D; Tardif, Jacques C; Zhai, Li-Hong; Wang, Fu-Sheng; Li, Bai-Lian
2015-01-01
Tree-rings are often assumed to approximate a circular shape when estimating forest productivity and carbon dynamics. However, tree rings are rarely, if ever, circular, thereby possibly resulting in under- or over-estimation in forest productivity and carbon sequestration. Given the crucial role played by tree ring data in assessing forest productivity and carbon storage within a context of global change, it is particularly important that mathematical models adequately render cross-sectional area increment derived from tree rings. We modeled the geometric shape of tree rings using the superellipse equation and checked its validation based on the theoretical simulation and six actual cross sections collected from three conifers. We found that the superellipse better describes the geometric shape of tree rings than the circle commonly used. We showed that a spiral growth trend exists on the radial section over time, which might be closely related to spiral grain along the longitudinal axis. The superellipse generally had higher accuracy than the circle in predicting the basal area increment, resulting in an improved estimate for the basal area. The superellipse may allow better assessing forest productivity and carbon storage in terrestrial forest ecosystems.
Resonant structure of low-energy H3+ dissociative recombination
NASA Astrophysics Data System (ADS)
Petrignani, Annemieke; Altevogt, Simon; Berg, Max H.; Bing, Dennis; Grieser, Manfred; Hoffmann, Jens; Jordon-Thaden, Brandon; Krantz, Claude; Mendes, Mario B.; Novotný, Oldřich; Novotny, Steffen; Orlov, Dmitry A.; Repnow, Roland; Sorg, Tobias; Stützel, Julia; Wolf, Andreas; Buhr, Henrik; Kreckel, Holger; Kokoouline, Viatcheslav; Greene, Chris H.
2011-03-01
High-resolution dissociative recombination rate coefficients of rotationally cool and hot H3+ in the vibrational ground state have been measured with a 22-pole trap setup and a Penning ion source, respectively, at the ion storage-ring TSR. The experimental results are compared with theoretical calculations to explore the dependence of the rate coefficient on ion temperature and to study the contributions of different symmetries to probe the rich predicted resonance spectrum. The kinetic energy release was investigated by fragment imaging to derive internal temperatures of the stored parent ions under differing experimental conditions. A systematic experimental assessment of heating effects is performed which, together with a survey of other recent storage-ring data, suggests that the present rotationally cool rate-coefficient measurement was performed at 380-130+50 K and that this is the lowest rotational temperature so far realized in storage-ring rate-coefficient measurements on H3+. This partially supports the theoretical suggestion that temperatures higher than assumed in earlier experiments are the main cause for the large gap between the experimental and the theoretical rate coefficients. For the rotationally hot rate-coefficient measurement a temperature of below 3250 K is derived. From these higher-temperature results it is found that increasing the rotational ion temperature in the calculations cannot fully close the gap between the theoretical and the experimental rate coefficients.
Storage Rings in the Sky: Gamma Ray Bursts and Galactic Gravitational Collapse Stored Energy
NASA Astrophysics Data System (ADS)
Greyber, H. D.
2004-05-01
The recent discovery of almost 100% polarization of the prompt gamma ray emission from GRB021206, (1), confirms my 44 year old ``Strong" Magnetic Field" model (SMF) for galactic dynamics. In SMF, Storage Ring particles were accelerated long ago during the original gravitational collapse of the pregalactic/prequasar plasma cloud that is permeated by an almost uniform primordial magnetic field (2,3) The enormous, intense, slender, relativistic, stable, completely coherent Storage Ring stores a very small fraction of the huge galactic gravitational collapse energy in an almost radiationless state, unless disturbed. The concept of an Astrophysical Storage Ring was introduced by me in l961. At first it was to explain galactic structure, but soon it proved useful to explain active galactic nuclei (AGN) and the dynamics of quasar/AGN jets. AGN and galactic morphology, energetics and dynamics vary as the ratio of magnetic energy to rotational energy in the particular object. Gamma ray bursts (GRB) are due simply to a ``rock". i.e. a white dwarf, ordinary star, neutron sstar, asteroid, planet, etc. falling rapidly through the Storage Ring and being almost instantly vaporized into a hot plasma fireball, causing an electromagnetic shower (2) Then the fireball speeds into the huge organized magnetic field surrounding the current ring, thus generating very highly polarized prompt gamma ray emission (as seen in GRB021206) from the synchrotron radiation process. The timing fits the GRB observations nicely. For instance, a ``rock" racing at 1000 kilometers per second across a 20,000 km. path in the beam would produce a twenty second burst. Other times, a target might track across a short chord for a short burst. Space missions have shown that often typical currents in space plasmas are made up of slender filaments. Thus the puzzling less than one millisecond spikes observed in some GRB are simply describing the structure of that particular ring current at that particular time. 1. W. Coburn and S.E. Boggs, Nature, 423, 415, (2003) 2. H. D. Greyber in a book, After the Dark Ages: When Galaxies Were Young, eds. S.S. Holt and E. P. Smith, AIP Conference Proceedings 470, 388-396. (1998) 3. H. D. Greyber in a Space Telescope Science Institute Report: Poster Papers from their 2001 Spring Symposium, ``The Dark Universe: Matter, Energy and Gravity," ed. Mario Livio, published March 2003, (34-39)
Beamline front end for in-vacuum short period undulator at the photon factory storage ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miyauchi, Hiroshi, E-mail: hiroshi.miyauchi@kek.jp; Department of Accelerator Science, School of High Energy Accelerator Science, SOKENDAI; Tahara, Toshihiro, E-mail: ttahara@post.kek.jp
The straight-section upgrade project of the Photon Factory created four new short straight sections capable of housing in-vacuum short period undulators. The first to fourth short period undulators SGU#17, SGU#03, SGU#01 and SGU#15 were installed at the 2.5-GeV Photon Factory storage ring in 2005, 2006, 2009 and 2013, respectively. The beamline front end for SGU#15 is described in this paper.
A storage ring experiment to detect a proton electric dipole moment
Anastassopoulos, V.; Andrianov, S.; Baartman, R.; ...
2016-11-29
We describe a new experiment to detect a permanent electric dipole moment of the proton with a sensitivity of 10 $-$29e cm by using polarized “magic” momentum 0.7 GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the scale of 3000 TeV.
A storage ring experiment to detect a proton electric dipole moment.
Anastassopoulos, V; Andrianov, S; Baartman, R; Baessler, S; Bai, M; Benante, J; Berz, M; Blaskiewicz, M; Bowcock, T; Brown, K; Casey, B; Conte, M; Crnkovic, J D; D'Imperio, N; Fanourakis, G; Fedotov, A; Fierlinger, P; Fischer, W; Gaisser, M O; Giomataris, Y; Grosse-Perdekamp, M; Guidoboni, G; Hacıömeroğlu, S; Hoffstaetter, G; Huang, H; Incagli, M; Ivanov, A; Kawall, D; Kim, Y I; King, B; Koop, I A; Lazarus, D M; Lebedev, V; Lee, M J; Lee, S; Lee, Y H; Lehrach, A; Lenisa, P; Levi Sandri, P; Luccio, A U; Lyapin, A; MacKay, W; Maier, R; Makino, K; Malitsky, N; Marciano, W J; Meng, W; Meot, F; Metodiev, E M; Miceli, L; Moricciani, D; Morse, W M; Nagaitsev, S; Nayak, S K; Orlov, Y F; Ozben, C S; Park, S T; Pesce, A; Petrakou, E; Pile, P; Podobedov, B; Polychronakos, V; Pretz, J; Ptitsyn, V; Ramberg, E; Raparia, D; Rathmann, F; Rescia, S; Roser, T; Kamal Sayed, H; Semertzidis, Y K; Senichev, Y; Sidorin, A; Silenko, A; Simos, N; Stahl, A; Stephenson, E J; Ströher, H; Syphers, M J; Talman, J; Talman, R M; Tishchenko, V; Touramanis, C; Tsoupas, N; Venanzoni, G; Vetter, K; Vlassis, S; Won, E; Zavattini, G; Zelenski, A; Zioutas, K
2016-11-01
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of 10 -29 e ⋅ cm by using polarized "magic" momentum 0.7 GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the standard model at the scale of 3000 TeV.
A storage ring experiment to detect a proton electric dipole moment
NASA Astrophysics Data System (ADS)
Anastassopoulos, V.; Andrianov, S.; Baartman, R.; Baessler, S.; Bai, M.; Benante, J.; Berz, M.; Blaskiewicz, M.; Bowcock, T.; Brown, K.; Casey, B.; Conte, M.; Crnkovic, J. D.; D'Imperio, N.; Fanourakis, G.; Fedotov, A.; Fierlinger, P.; Fischer, W.; Gaisser, M. O.; Giomataris, Y.; Grosse-Perdekamp, M.; Guidoboni, G.; Hacıömeroǧlu, S.; Hoffstaetter, G.; Huang, H.; Incagli, M.; Ivanov, A.; Kawall, D.; Kim, Y. I.; King, B.; Koop, I. A.; Lazarus, D. M.; Lebedev, V.; Lee, M. J.; Lee, S.; Lee, Y. H.; Lehrach, A.; Lenisa, P.; Levi Sandri, P.; Luccio, A. U.; Lyapin, A.; MacKay, W.; Maier, R.; Makino, K.; Malitsky, N.; Marciano, W. J.; Meng, W.; Meot, F.; Metodiev, E. M.; Miceli, L.; Moricciani, D.; Morse, W. M.; Nagaitsev, S.; Nayak, S. K.; Orlov, Y. F.; Ozben, C. S.; Park, S. T.; Pesce, A.; Petrakou, E.; Pile, P.; Podobedov, B.; Polychronakos, V.; Pretz, J.; Ptitsyn, V.; Ramberg, E.; Raparia, D.; Rathmann, F.; Rescia, S.; Roser, T.; Kamal Sayed, H.; Semertzidis, Y. K.; Senichev, Y.; Sidorin, A.; Silenko, A.; Simos, N.; Stahl, A.; Stephenson, E. J.; Ströher, H.; Syphers, M. J.; Talman, J.; Talman, R. M.; Tishchenko, V.; Touramanis, C.; Tsoupas, N.; Venanzoni, G.; Vetter, K.; Vlassis, S.; Won, E.; Zavattini, G.; Zelenski, A.; Zioutas, K.
2016-11-01
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of 10-29 e ṡ cm by using polarized "magic" momentum 0.7 GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the standard model at the scale of 3000 TeV.
FLSR - The Frankfurt low energy storage ring
NASA Astrophysics Data System (ADS)
Stiebing, K. E.; Alexandrov, V.; Dörner, R.; Enz, S.; Kazarinov, N. Yu.; Kruppi, T.; Schempp, A.; Schmidt Böcking, H.; Völp, M.; Ziel, P.; Dworak, M.; Dilfer, W.
2010-02-01
An electrostatic storage ring for low-energy ions with a design energy of 50 keV is presently being set up at the Institut für Kernphysik der Johann Wolfgang Goethe-Universität Frankfurt am Main, Germany (IKF). This new device will provide a basis for new experiments on the dynamics of ionic and molecular collisions, as well as for high precision and time resolved laser spectroscopy. In this article, the design parameters of this instrument are reported.
The Status of the Taiwan Photon Source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuo, C. C.; Wang, J. P.; Chen, J. R.
2010-06-23
NSRRC has been operating a 1.5 GeV synchrotron light source, the Taiwan Light Source (TLS), for over 15 years and has established a large user community. For the future development of synchrotron radiation research in Taiwan, a feasibility study report to construct a 3.0 GeV low-emittance storage ring, the Taiwan Photon Source (TPS), was issued in July 2005. The government approval of the TPS project was obtained in December 2007 and the machine will be built at current site of NSRRC. The project has progressed steadily since and reached several major milestones now: the architect firm has finished the sitemore » plan and civil design, the accelerator design has been fixed, and purchase of long-lead items begins its course. The TPS storage ring has a circumference of 518.4 meters with a concentric booster of 496.8 meters. The storage ring adopted a 24-cell double-bend structure with a 1.6 nm-rad natural emittance. There are six 12-m and eighteen 7-m ID straights. For user research, five new beamlines have been selected for the Phase I operations: the micro protein crystallography, the materials sub-micron diffraction, the inelastic soft x-ray scattering, the coherent x-ray scattering, and the nano probe beamlines. The civil construction is getting ready to start. The commissioning of the TPS storage ring is targeted for 2013.« less
NASA Astrophysics Data System (ADS)
Xu, Wei; Li, Jing-Yi; Huang, Sen-Lin; Z. Wu, W.; Hao, H.; P., Wang; K. Wu, Y.
2014-10-01
The Duke storage ring is a dedicated driver for the storage ring based oscillator free-electron lasers (FELs), and the High Intensity Gamma-ray Source (HIGS). It is operated with a beam current ranging from about 1 mA to 100 mA per bunch for various operations and accelerator physics studies. High performance operations of the FEL and γ-ray source require a stable electron beam orbit, which has been realized by the global orbit feedback system. As a critical part of the orbit feedback system, the electron beam position monitors (BPMs) are required to be able to precisely measure the electron beam orbit in a wide range of the single-bunch current. However, the high peak voltage of the BPM pickups associated with high single-bunch current degrades the performance of the BPM electronics, and can potentially damage the BPM electronics. A signal conditioning method using low pass filters is developed to reduce the peak voltage to protect the BPM electronics, and to make the BPMs capable of working with a wide range of single-bunch current. Simulations and electron beam based tests are performed. The results show that the Duke storage ring BPM system is capable of providing precise orbit measurements to ensure highly stable FEL and HIGS operations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W.; Mcwilliams, A.; Skidmore, E.
The 9975 Type B shipping package is used within the DOE complex for shipping special nuclear materials. This package is re-certified annually in accordance with Safety Analysis Report requirements. The package is also used at the Savannah River Site as part of the long-term storage configuration of special nuclear materials. As such, the packages do not undergo annual recertification during storage, with uncertainty as to how long some of the package components will meet their functional requirements in the storage environment. The packages are currently approved for up to 15 years storage, and work continues to provide a technical basismore » to extend that period. This paper describes efforts by the Savannah River National Laboratory (SRNL) to extend the service life estimate of Viton® GLT and GLT-S fluoroelastomer O-rings used in the 9975 shipping package. O-rings of both compositions are undergoing accelerated aging at elevated temperature, and are periodically tested for compression stress relaxation (CSR) behavior and leak performance. The CSR behavior of O-rings was evaluated at temperatures from 79 °C to 177 °C. These collective data were used to develop predictive models for extrapolation of CSR behavior to relevant service temperatures (< 75 °C). O-rings were also aged in Primary Containment Vessel (PCV) fixtures at temperatures ranging from 79 °C to 232 °C. The fixtures are helium leak tested periodically to determine if they remain leak-tight. The PCV fixture tests demonstrate that the 9975 O-rings will remain leak-tight at temperatures up to 149 °C for 3 years or more, and no leak failures have been observed with up to 8 years aging at 93 °C. Significantly longer periods of leak-tight service are expected at the lower temperatures actually experienced in the storage environment. The predictive model developed from the CSR data conservatively indicates a service life of more than 20 years at the bounding temperature of 75 °C. Although the relationship between CSR behavior and leak-tight performance has not been established for this design, the CSR predictions for this O-ring are conservative relative to leak-tight performance to date.« less
Design of 3 GeV booster ring lattice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Etisken, O., E-mail: ozgur.etisken@cern.ch; Ciftci, A. K., E-mail: abbas.kenan.ciftci@cern.ch
2016-03-25
The aim of this study is to design of a 3 GeV booster ring for the 3 GeV storage ring. Electrons are needed to be accelerated to 3.0 GeV from 0.15 GeV energy. In this frame, we studied on two options for booster ring; a compact booster and the booster that shares the same tunnel with the storage ring. The lattice type has been chosen FODO for both options, lattice parameters are calculated, sextupole magnets are used to decrease dynamic aperture problem and dynamic aperture calculations are also made with considering of the necessary conditions. After designing and calculating ofmore » the parameters, these designs have been compared with each other. In addition to this comparison, these booster design parameters have been compared with some world centers design parameters and the reliability of the booster design is seen. Beam optics, OPA and Elegant simulation programs have been used in the study calculations.« less
cMapper: gene-centric connectivity mapper for EBI-RDF platform.
Shoaib, Muhammad; Ansari, Adnan Ahmad; Ahn, Sung-Min
2017-01-15
In this era of biological big data, data integration has become a common task and a challenge for biologists. The Resource Description Framework (RDF) was developed to enable interoperability of heterogeneous datasets. The EBI-RDF platform enables an efficient data integration of six independent biological databases using RDF technologies and shared ontologies. However, to take advantage of this platform, biologists need to be familiar with RDF technologies and SPARQL query language. To overcome this practical limitation of the EBI-RDF platform, we developed cMapper, a web-based tool that enables biologists to search the EBI-RDF databases in a gene-centric manner without a thorough knowledge of RDF and SPARQL. cMapper allows biologists to search data entities in the EBI-RDF platform that are connected to genes or small molecules of interest in multiple biological contexts. The input to cMapper consists of a set of genes or small molecules, and the output are data entities in six independent EBI-RDF databases connected with the given genes or small molecules in the user's query. cMapper provides output to users in the form of a graph in which nodes represent data entities and the edges represent connections between data entities and inputted set of genes or small molecules. Furthermore, users can apply filters based on database, taxonomy, organ and pathways in order to focus on a core connectivity graph of their interest. Data entities from multiple databases are differentiated based on background colors. cMapper also enables users to investigate shared connections between genes or small molecules of interest. Users can view the output graph on a web browser or download it in either GraphML or JSON formats. cMapper is available as a web application with an integrated MySQL database. The web application was developed using Java and deployed on Tomcat server. We developed the user interface using HTML5, JQuery and the Cytoscape Graph API. cMapper can be accessed at http://cmapper.ewostech.net Readers can download the development manual from the website http://cmapper.ewostech.net/docs/cMapperDocumentation.pdf. Source Code is available at https://github.com/muhammadshoaib/cmapperContact:smahn@gachon.ac.krSupplementary information: Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Silva, Vanessa Honda Ogihara; Dos Santos Batista, Ana Paula; Silva Costa Teixeira, Antonio Carlos; Borrely, Sueli Ivone
2016-06-01
Electron beam irradiation (EBI) has been considered an advanced technology for the treatment of water and wastewater, whereas very few previous investigations reported its use for removing pharmaceutical pollutants. In this study, the degradation of fluoxetine (FLX), an antidepressant marketed as Prozac(®), was investigated by using EBI at FLX initial concentration of 19.4 ± 0.2 mg L(-1). More than 90 % FLX degradation was achieved at 0.5 kGy, with FLX below the detection limit (0.012 mg L(-1)) at doses higher than 2.5 kGy. The elucidation of organic byproducts performed using direct injection mass spectrometry, along with the results of ion chromatography, indicated hydroxylation of FLX molecules with release of fluoride and nitrate anions. Nevertheless, about 80 % of the total organic carbon concentration remained even for 7.5 kGy or higher doses. The decreases in acute toxicity achieved 86.8 and 9.6 % for Daphnia similis and Vibrio fischeri after EBI exposure at 5 kGy, respectively. These results suggest that EBI could be an alternative to eliminate FLX and to decrease residual toxicity from wastewater generated in pharmaceutical formulation facilities, although further investigation is needed for correlating the FLX degradation mechanism with the toxicity results.
Leyva, Bryan; Allen, Jennifer D; Ospino, Hosffman; Tom, Laura S; Negrón, Rosalyn; Buesa, Richard; Torres, Maria Idalí
2017-09-01
Evidence-based interventions (EBIs) to promote cancer control among Latinos have proliferated in recent years, though adoption and implementation of these interventions by faith-based organizations (FBOs) is limited. Capacity building may be one strategy to promote implementation. In this qualitative study, 18 community key informants were interviewed to (a) understand existing capacity for health programming among Catholic parishes, (b) characterize parishes' resource gaps and capacity-building needs implementing cancer control EBIs, and (c) elucidate strategies for delivering capacity-building assistance to parishes to facilitate implementation of EBIs. Semi-structured qualitative interviews were conducted. Key informants concurred about the capacity of Catholic parishes to deliver health programs, and described attributes of parishes that make them strong partners in health promotion initiatives, including a mission to address physical and mental health, outreach to marginalized groups, altruism among members, and existing engagement in health programming. However, resource gaps and capacity building needs were also identified. Specific recommendations participants made about how existing resources might be leveraged to address challenges include to: establish parish wellness committees; provide "hands-on" learning opportunities for parishioners to gain program planning skills; offer continuous, tailored, on-site technical assistance; facilitate relationships between parishes and community resources; and provide financial support for parishes. Leveraging parishes' existing resources and addressing their implementation needs may improve adoption of cancer control EBIs.
You, Wanchun; Wang, Zhong; Li, Haiying; Shen, Haitao; Xu, Xiang; Jia, Genlai; Chen, Gang
2016-08-15
Here, we aimed to study the role and underlying mechanism of mTOR in early brain injury (EBI) after subarachnoid hemorrhage (SAH). Experiment 1, the time course of mTOR activation in the cortex following SAH. Experiment 2, the role of mTOR in SAH-induced EBI. Adult SD rats were divided into four groups: sham group (n=18), SAH+vehicle group (n=18), SAH+rapamycin group (n=18), SAH+AZD8055 group (n=18). Experiment 3, we incubated enriched microglia with OxyHb. Rapamycin and AZD8055 were also used to demonstrate the mTOR's role on microglial polarization in vitro. The phosphorylation levels of mTOR and its substrates were significantly increased and peaked at 24h after SAH. Rapamycin or AZD8055 markedly decreased the phosphorylation levels of mTOR and its substrates and the activation of microglia in vivo, and promoted the microglial polarization from M1 phenotype to M2 phenotype. In addition, administration of rapamycin and AZD8055 following SAH significantly ameliorated EBI, including neuronal apoptosis, neuronal necrosis, brain edema and blood-brain barrier permeability. Our findings suggested that the rapamycin and AZD8055 could attenuate the development of EBI in this SAH model, possibly through inhibiting the activation of microglia by mTOR pathway. Copyright © 2016 Elsevier B.V. All rights reserved.
Intra-Beam Scattering, Impedance, and Instabilities in Ultimate Storage Rings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bane, Karl; /SLAC
We have investigated collective effects in an ultimate storage ring, i.e. one with diffraction limited emittances in both planes, using PEP-X as an example. In an ultimate ring intra-beam scattering (IBS) sets the limit of current that can be stored. In PEP-X, a 4.5 GeV ring running round beams at 200 mA in 3300 bunches, IBS doubles the emittances to 11.5 pm at the design current. The Touschek lifetime is 11 hours. Impedance driven collective effects tend not to be important since the beam current is relatively low. We have investigated collective effects in PEP-X, an ultimate storage ring, i.e.more » one with diffraction limited emittances (at one angstrom wavelength) in both planes. In an ultimate ring intra-beam scattering (IBS) sets the limit of current that can be stored. In PEP-X, IBS doubles the emittances to 11.5 pm at the design current of 200 mA, assuming round beams. The Touschek lifetime is quite large in PEP-X, 11.6 hours, and - near the operating point - increases with decreasing emittance. It is, however, a very sensitive function of momentum acceptance. In an ultimate ring like PEP-X impedance driven collective effects tend not to be important since the beam current is relatively low. Before ultimate PEP-X can be realized, the question of how to run a machine with round beams needs serious study. For example, in this report we assumed that the vertical emittance is coupling dominated. It may turn out that using vertical dispersion is a preferable way to generate round beams. The choice will affect IBS and the Touschek effect.« less
Properties of the electron cloud in a high-energy positron and electron storage ring
Harkay, K. C.; Rosenberg, R. A.
2003-03-20
Low-energy, background electrons are ubiquitous in high-energy particle accelerators. Under certain conditions, interactions between this electron cloud and the high-energy beam can give rise to numerous effects that can seriously degrade the accelerator performance. These effects range from vacuum degradation to collective beam instabilities and emittance blowup. Although electron-cloud effects were first observed two decades ago in a few proton storage rings, they have in recent years been widely observed and intensely studied in positron and proton rings. Electron-cloud diagnostics developed at the Advanced Photon Source enabled for the first time detailed, direct characterization of the electron-cloud properties in amore » positron and electron storage ring. From in situ measurements of the electron flux and energy distribution at the vacuum chamber wall, electron-cloud production mechanisms and details of the beam-cloud interaction can be inferred. A significant longitudinal variation of the electron cloud is also observed, due primarily to geometrical details of the vacuum chamber. Furthermore, such experimental data can be used to provide realistic limits on key input parameters in modeling efforts, leading ultimately to greater confidence in predicting electron-cloud effects in future accelerators.« less
Status of NSLS-II Storage Ring Vacuum Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doom,L.; Hseuh,H.; Ferreira, M.
2009-05-04
National Synchrotron Light Source II (NSLS-II), being constructed at Brookhaven National Laboratory, is a 3-GeV, high-flux and high- brightness synchrotron radiation facility with a nominal current of 500 mA. The storage ring vacuum system will have extruded aluminium chambers with ante-chamber for photon fans and distributed NEG strip pumping. Discrete photon absorbers will be used to intercept the un-used bending magnet radiation. In-situ bakeout will be implemented to achieve fast conditioning during initial commissioning and after interventions.
Saw-tooth instability in storage rings: simulations and dynamical model
NASA Astrophysics Data System (ADS)
Migliorati, M.; Palumbo, L.; Dattoli, G.; Mezi, L.
1999-11-01
The saw-tooth instability in storage rings is studied by means of a time-domain simulation code which takes into account the self-induced wake fields. The results are compared with those from a dynamical heuristic model exploiting two coupled non-linear differential equations, accounting for the time behavior of the instability growth rate and for the anomalous growth of the energy spread. This model is shown to reproduce the characteristic features of the instability in a fairly satisfactory way.
A storage ring experiment to detect a proton electric dipole moment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anastassopoulos, V.; Andrianov, S.; Baartman, R.
2016-11-01
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity ofmore » $$10^{-29}e\\cdot$$cm by using polarized "magic" momentum $0.7$~GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the scale of 3000~TeV.« less
Storage rings for spin-polarized hydrogen
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, D.; Lovelace, R.V.E.; Lee, D.
1989-11-01
A strong-focusing storage ring is proposed for the long-term magnetic confinement of a collisional gas of neutral spin-polarized hydrogen atoms in the Za{l arrow} and Zb{l arrow} hyperfine states. The trap uses the interaction of the magnetic moments of the gas atoms with a static magnetic field. Laser cooling and evaporative cooling can be utilized to enhance the confinement and to offset the influence of viscous heating. An important application of the trap is to the attainment of Bose--Einstein condensation.
Photoswitchable Dihydroazulene Macrocycles for Solar Energy Storage: The Effects of Ring Strain.
Vlasceanu, Alexandru; Frandsen, Benjamin N; Skov, Anders B; Hansen, Anne Schou; Rasmussen, Mads Georg; Kjaergaard, Henrik G; Mikkelsen, Kurt V; Nielsen, Mogens Brøndsted
2017-10-06
Efficient energy storage and release are two major challenges of solar energy harvesting technologies. The development of molecular solar thermal systems presents one approach to address these issues by tuning the isomerization reactions of photo/thermoswitches. Here we show that the incorporation of photoswitches into macrocyclic structures is a particularly attractive solution for increasing the storage time. We present the synthesis and properties of a series of macrocycles incorporating two dihydroazulene (DHA) photoswitching subunits, bridged by linkers of varying chain length. Independent of ring size, all macrocycles exhibit stepwise, light-induced, ring-opening reactions (DHA-DHA to DHA-VHF to VHF-VHF; VHF = vinylheptafulvene) with the first DHA undergoing isomerization with a similar efficiency as the uncyclized parent system while the second (DHA-VHF to VHF-VHF) is significantly slower. The energy-releasing, VHF-to-DHA, ring closures also occur in a stepwise manner and are systematically found to proceed slower in the more strained (smaller) cycles, but in all cases with a remarkably slow conversion of the second VHF to DHA. We managed to increase the half-life of the second VHF-to-DHA conversion from 65 to 202 h at room temperature by simply decreasing the ring size. A computational study reveals the smallest macrocycle to have the most energetic VHF-VHF state and hence highest energy density.
NASA Technical Reports Server (NTRS)
Wingard, Doug
2006-01-01
After the rollout of Space Shuttle Discovery in April 2005 in preparation for return-to-flight, there was a failure of the Orbiter (OV-103) helium signature leak test in the gaseous hydrogen (GH2) system. Leakage was attributed to the Flow Control Valve (FCV) in Main Engine 3. The FCV determined to be the source of the leak for OV-103 is designated as LV-58. The nitrile/Buna N rubber O-ring seal was removed from LV-58, and failure analysis indicated radial cracks providing leak paths in one quadrant. Cracks were eventually found in 6 of 9 FCV O-rings among the three Shuttle Orbiters, though none were as severe as those for LV-58, OV-103. Testing by EM10 at MSFC on all 9 FCV O- rings included: laser dimensional, Shore A hardness and properties from a dynamic mechanical analyzer (DMA) and an Instron tensile machine. The following test data was obtained on the cracked quadrant of the LV-58, OV-103 O-ring: (1) the estimated compression set was only 9.5%, compared to none for the rest of the O-ring; (2) Shore A hardness for the O.D. was higher by almost 4 durometer points than for the rest of the O-ring; and (3) DMA data showed that the storage/elastic modulus E was almost 25% lower than for the rest of the O-ring. Of the 8 FCV O-rings tested on an Instron, 4 yielded tensile strengths that were below the MIL spec requirement of 1350 psi-a likely influence of rubber cracking. Comparisons were made between values of modulus determined by DNA (elastic) and Instron (Young s). Each nitrile/Buna N O-ring used in the FCV conforms to the MIL-P-25732C specification. A number of such O-rings taken from shelf storage at MSFC and Kennedy Space Center (KSC) were used to generate a reference curve of DMA glass transition temperature (Tg) vs. shelf storage time ranging from 8 to 26 years. A similar reference curve of TGA onset temperature (of rubber weight loss) vs. shelf storage time was also generated. The DMA and TGA data for the used FCV O-rings were compared to the reference curves. Correlations were also made between the DMA modulus (at 22 C) and Shore A hardness for all 9 of the FCV O-rings used among the three Shuttle Orbiters. The radial cracking in the FCV O-rings was determined to be due to ozone attack, as nitrile/Buna N rubber is susceptible to such attack. Nitrile/Buna N material under MIL-P25732C should be used in a hydraulic fluid environment to help protect it from cracking. However, the FCV O-rings were used in an air only environment. The FCV design has as much as a 9-mil gap that allows the O.D. of the O-ring to be directly exposed to ozone, pressurized air and some elevated temperatures, accelerating the weathering process that leads to O-ring cracking. Space Shuttle flights will likely not continue past 2010. Therefore, Shuttle management decided to continue using the nitrile/Buna N material for the FCVs, but have each O-ring replaced after 3 years to minimize any chances for crack initiation.
Flexible matrix composite laminated disk/ring flywheel
NASA Technical Reports Server (NTRS)
Gupta, B. P.; Hannibal, A. J.
1984-01-01
An energy storage flywheel consisting of a quasi-isotropic composite disk overwrapped by a circumferentially wound ring made of carbon fiber and a elastometric matrix is proposed. Through analysis it was demonstrated that with an elastomeric matrix to relieve the radial stresses, a laminated disk/ring flywheel can be designed to store a least 80.3 Wh/kg or about 68% more than previous disk/ring designs. at the same time the simple construction is preserved.
A System for Information Management in BioMedical Studies—SIMBioMS
Krestyaninova, Maria; Zarins, Andris; Viksna, Juris; Kurbatova, Natalja; Rucevskis, Peteris; Neogi, Sudeshna Guha; Gostev, Mike; Perheentupa, Teemu; Knuuttila, Juha; Barrett, Amy; Lappalainen, Ilkka; Rung, Johan; Podnieks, Karlis; Sarkans, Ugis; McCarthy, Mark I; Brazma, Alvis
2009-01-01
Summary: SIMBioMS is a web-based open source software system for managing data and information in biomedical studies. It provides a solution for the collection, storage, management and retrieval of information about research subjects and biomedical samples, as well as experimental data obtained using a range of high-throughput technologies, including gene expression, genotyping, proteomics and metabonomics. The system can easily be customized and has proven to be successful in several large-scale multi-site collaborative projects. It is compatible with emerging functional genomics data standards and provides data import and export in accepted standard formats. Protocols for transferring data to durable archives at the European Bioinformatics Institute have been implemented. Availability: The source code, documentation and initialization scripts are available at http://simbioms.org. Contact: support@simbioms.org; mariak@ebi.ac.uk PMID:19633095
An infrastructure for ontology-based information systems in biomedicine: RICORDO case study.
Wimalaratne, Sarala M; Grenon, Pierre; Hoehndorf, Robert; Gkoutos, Georgios V; de Bono, Bernard
2012-02-01
The article presents an infrastructure for supporting the semantic interoperability of biomedical resources based on the management (storing and inference-based querying) of their ontology-based annotations. This infrastructure consists of: (i) a repository to store and query ontology-based annotations; (ii) a knowledge base server with an inference engine to support the storage of and reasoning over ontologies used in the annotation of resources; (iii) a set of applications and services allowing interaction with the integrated repository and knowledge base. The infrastructure is being prototyped and developed and evaluated by the RICORDO project in support of the knowledge management of biomedical resources, including physiology and pharmacology models and associated clinical data. The RICORDO toolkit and its source code are freely available from http://ricordo.eu/relevant-resources. sarala@ebi.ac.uk.
NASA Astrophysics Data System (ADS)
Talman, Richard M.; Talman, John D.
2015-07-01
There has been much recent interest in directly measuring the electric dipole moments (EDM) of the proton and the electron, because of their possible importance in the present day observed matter/antimatter imbalance in the Universe. Such a measurement will require storing a polarized beam of "frozen spin" particles, 15 MeV electrons or 230 MeV protons, in an all-electric storage ring. Only one such relativistic electric accelerator has ever been built—the 10 MeV "electron analog" ring at Brookhaven National Laboratory in 1954; it can also be referred to as the "AGS analog" ring to make clear it was a prototype for the Alternating Gradient Synchrotron (AGS) proton ring under construction at that time at BNL. (Its purpose was to investigate nonlinear resonances as well as passage through "transition" with the newly invented alternating gradient proton ring design.) By chance this electron ring, long since dismantled and its engineering drawings disappeared, would have been appropriate both for measuring the electron EDM and to serve as an inexpensive prototype for the arguably more promising, but 10 times more expensive, proton EDM measurement. Today it is cheaper yet to "resurrect" the electron analog ring by simulating its performance computationally. This is one purpose for the present paper. Most existing accelerator simulation codes cannot be used for this purpose because they implicitly assume magnetic bending. The new ual/eteapot code, described in detail in an accompanying paper, has been developed for modeling storage ring performance, including spin evolution, in electric rings. Illustrating its use, comparing its predictions with the old observations, and describing new expectations concerning spin evolution and code performance, are other goals of the paper. To set up some of these calculations has required a kind of "archeological physics" to reconstitute the detailed electron analog lattice design from a 1991 retrospective report by Plotkin as well as unpublished notes of Courant describing machine studies performed in 1954-1955. This paper describes the practical application of the eteapot code and provides sample results, with emphasis on emulating lattice optics in the AGS analog ring for comparison with the historical machine studies and to predict the electron spin evolution they would have measured if they had polarized electrons and electron polarimetry. Of greater present day interest is the performance to be expected for a proton storage ring experiment. To exhibit the eteapot code performance and confirm its symplecticity, results are also given for 30 million turn proton spin tracking in an all-electric lattice that would be appropriate for a present day measurement of the proton EDM. The accompanying paper "Symplectic orbit and spin tracking code for all-electric storage rings" documents in detail the theoretical formulation implemented in eteapot, which is a new module in the Unified Accelerator Libraries (ual) environment.
Phase measurement for driven spin oscillations in a storage ring
NASA Astrophysics Data System (ADS)
Hempelmann, N.; Hejny, V.; Pretz, J.; Soltner, H.; Augustyniak, W.; Bagdasarian, Z.; Bai, M.; Barion, L.; Berz, M.; Chekmenev, S.; Ciullo, G.; Dymov, S.; Eversmann, D.; Gaisser, M.; Gebel, R.; Grigoryev, K.; Grzonka, D.; Guidoboni, G.; Heberling, D.; Hetzel, J.; Hinder, F.; Kacharava, A.; Kamerdzhiev, V.; Keshelashvili, I.; Koop, I.; Kulikov, A.; Lehrach, A.; Lenisa, P.; Lomidze, N.; Lorentz, B.; Maanen, P.; Macharashvili, G.; Magiera, A.; Mchedlishvili, D.; Mey, S.; Müller, F.; Nass, A.; Nikolaev, N. N.; Nioradze, M.; Pesce, A.; Prasuhn, D.; Rathmann, F.; Rosenthal, M.; Saleev, A.; Schmidt, V.; Semertzidis, Y.; Senichev, Y.; Shmakova, V.; Silenko, A.; Slim, J.; Stahl, A.; Stassen, R.; Stephenson, E.; Stockhorst, H.; Ströher, H.; Tabidze, M.; Tagliente, G.; Talman, R.; Thörngren Engblom, P.; Trinkel, F.; Uzikov, Yu.; Valdau, Yu.; Valetov, E.; Vassiliev, A.; Weidemann, C.; Wrońska, A.; Wüstner, P.; Zuprański, P.; Żurek, M.; JEDI Collaboration
2018-04-01
This paper reports the first simultaneous measurement of the horizontal and vertical components of the polarization vector in a storage ring under the influence of a radio frequency (rf) solenoid. The experiments were performed at the Cooler Synchrotron COSY in Jülich using a vector polarized, bunched 0.97 GeV /c deuteron beam. Using the new spin feedback system, we set the initial phase difference between the solenoid field and the precession of the polarization vector to a predefined value. The feedback system was then switched off, allowing the phase difference to change over time, and the solenoid was switched on to rotate the polarization vector. We observed an oscillation of the vertical polarization component and the phase difference. The oscillations can be described using an analytical model. The results of this experiment also apply to other rf devices with horizontal magnetic fields, such as Wien filters. The precise manipulation of particle spins in storage rings is a prerequisite for measuring the electric dipole moment (EDM) of charged particles.
EUTERPE, a small electron storage ring for XRF
NASA Astrophysics Data System (ADS)
Botman, J. I. M.; Mutsaers, P. H. A.; Hagedoorn, H. L.; De Voigt, M. J. A.
1990-04-01
A small-sized electron storage ring is under construction at the Eindhoven University of Technology which will cover the energy range of 15 to 400 MeV. At top energy the characteristic wavelength of the synchrotron radiation spectrum is 8.3 nm for the regular dipole magnets and 1.2 nm corresponding to 1.06 keV for a 10 T wiggler magnet. This will provide useful radiation for X-ray fluorescence (XRF) up to 3.2 keV. Alternatively, photon conversion with a high power CO 2 laser beam of 0.124 eV photons will generate X-rays for XRF with energies ranging from 0.5 to 300 keV, depending on the operating energy of the storage ring. This facility will provide an important extension to the activities of the Eindhoven group on PIXE, RBS and microbeam analysis. A short description of the macnine will be given together with applications and specific examples of the XRF method.
Magnetic Measurements of Storage Ring Magnets for the APS Upgrade Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doose, C.; Dejus, R.; Jaski, M.
2017-06-01
Extensive prototyping of storage ring magnets is ongoing at the Advanced Photon Source (APS) in support of the APS Multi-Bend Achromat (MBA) upgrade project (APS-U) [1]. As part of the R&D activities four quadrupole magnets with slightly different geometries and pole tip materials, and one sextupole magnet with vanadium permendur (VP) pole tips were designed, built and tested. Magnets were measured individually using a rotating coil and a Hall probe for detailed mapping of the magnetic field. Magnets were then assembled and aligned relative to each other on a steel support plate and concrete plinth using precision machined surfaces tomore » gain experience with the alignment method chosen for the APS-U storage ring magnets. The required alignment of magnets on a common support structure is 30 μm rms. Measurements of magnetic field quality, strength and magnet alignment after subjecting the magnets and assemblies to different tests are presented.« less
Constrained multi-objective optimization of storage ring lattices
NASA Astrophysics Data System (ADS)
Husain, Riyasat; Ghodke, A. D.
2018-03-01
The storage ring lattice optimization is a class of constrained multi-objective optimization problem, where in addition to low beam emittance, a large dynamic aperture for good injection efficiency and improved beam lifetime are also desirable. The convergence and computation times are of great concern for the optimization algorithms, as various objectives are to be optimized and a number of accelerator parameters to be varied over a large span with several constraints. In this paper, a study of storage ring lattice optimization using differential evolution is presented. The optimization results are compared with two most widely used optimization techniques in accelerators-genetic algorithm and particle swarm optimization. It is found that the differential evolution produces a better Pareto optimal front in reasonable computation time between two conflicting objectives-beam emittance and dispersion function in the straight section. The differential evolution was used, extensively, for the optimization of linear and nonlinear lattices of Indus-2 for exploring various operational modes within the magnet power supply capabilities.
ACCELERATORS: Beam based alignment of the SSRF storage ring
NASA Astrophysics Data System (ADS)
Zhang, Man-Zhou; Li, Hao-Hu; Jiang, Bo-Cheng; Liu, Gui-Min; Li, De-Ming
2009-04-01
There are 140 beam position monitors (BPMs) in the Shanghai Synchrotron Radiation Facility (SSRF) storage ring used for measuring the closed orbit. As the BPM pickup electrodes are assembled directly on the vacuum chamber, it is important to calibrate the electrical center offset of the BPM to an adjacent quadrupole magnetic center. A beam based alignment (BBA) method which varies individual quadrupole magnet strength and observes its effects on the orbit is used to measure the BPM offsets in both the horizontal and vertical planes. It is a completely automated technique with various data processing methods. There are several parameters such as the strength change of the correctors and the quadrupoles which should be chosen carefully in real measurement. After several rounds of BBA measurement and closed orbit correction, these offsets are set to an accuracy better than 10 μm. In this paper we present the method of beam based calibration of BPMs, the experimental results of the SSRF storage ring, and the error analysis.
Symplectic orbit and spin tracking code for all-electric storage rings
Talman, Richard M.; Talman, John D.
2015-07-22
Proposed methods for measuring the electric dipole moment (EDM) of the proton use an intense, polarized proton beam stored in an all-electric storage ring “trap.” At the “magic” kinetic energy of 232.792 MeV, proton spins are “frozen,” for example always parallel to the instantaneous particle momentum. Energy deviation from the magic value causes in-plane precession of the spin relative to the momentum. Any nonzero EDM value will cause out-of-plane precession—measuring this precession is the basis for the EDM determination. A proposed implementation of this measurement shows that a proton EDM value of 10 –29e–cm or greater will produce a statisticallymore » significant, measurable precession after multiply repeated runs, assuming small beam depolarization during 1000 s runs, with high enough precision to test models of the early universe developed to account for the present day particle/antiparticle population imbalance. This paper describes an accelerator simulation code, eteapot, a new component of the Unified Accelerator Libraries (ual), to be used for long term tracking of particle orbits and spins in electric bend accelerators, in order to simulate EDM storage ring experiments. Though qualitatively much like magnetic rings, the nonconstant particle velocity in electric rings gives them significantly different properties, especially in weak focusing rings. Like the earlier code teapot (for magnetic ring simulation) this code performs exact tracking in an idealized (approximate) lattice rather than the more conventional approach, which is approximate tracking in a more nearly exact lattice. The Bargmann-Michel-Telegdi (BMT) equation describing the evolution of spin vectors through idealized bend elements is also solved exactly—original to this paper. Furthermore the idealization permits the code to be exactly symplectic (with no artificial “symplectification”). Any residual spurious damping or antidamping is sufficiently small to permit reliable tracking for the long times, such as the 1000 s assumed in estimating the achievable EDM precision. This paper documents in detail the theoretical formulation implemented in eteapot. An accompanying paper describes the practical application of the eteapot code in the Universal Accelerator Libraries (ual) environment to “resurrect,” or reverse engineer, the “AGS-analog” all-electric ring built at Brookhaven National Laboratory in 1954. Of the (very few) all-electric rings ever commissioned, the AGS-analog ring is the only relativistic one and is the closest to what is needed for measuring proton (or, even more so, electron) EDM’s. As a result, the companion paper also describes preliminary lattice studies for the planned proton EDM storage rings as well as testing the code for long time orbit and spin tracking.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eriksson, Mikael
Not very long ago, the 3{sup rd} generation storage ring technology was judged as mature. Most of the 3{sup rd} generation storage rings used the Double-Bend Achromat (DBA) or Triple-Bend Achromat (TBA) concepts. It was however a well-known fact that increasing the number of magnet cells in the rings is a powerful way of decreasing the electron beam emittance and thus the source brilliance, but at the penalty of increasing the size and cost of the rings. Preserving the Dynamic Aperture (DA) in the rings became also an issue when increasing the number of magnet cells. The Multi-Bend Achromat (MBA)more » concept, including a miniaturization of the ring elements, has now drastically changed the picture. The MBA rings, now in construction or being planned, offer orders of magnitudes higher brilliance than rings of conventional designs. Several light sources around the world are now implementing or planning to implement this MBA concept. This article touches on the science drivers for higher brilliance. We will then describe the MBA concept with its advantages as well as its challenges. A short survey of the MBA activity around the world will also be presented. The author apologies for focusing on the MAX IV project regarding technical solutions. This is motivated by that MAX IV is the facility he knows best and it might be regarded as a fore-runner for the MBA concept.« less
The Abort Kicker System for the PEP-II Storage Rings at SLAC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delamare, Jeffrey E
2003-06-20
The PEP-II project has two storage rings. The HER (High Energy Ring) has up to 1.48 A of election beam at 9 GeV, and the LER (Low Energy Ring) has up to 2.14 A of positron beam at 3.1 GeV. To protect the HER and LER beam lines in the event of a ring component failure, each ring has an abort kicker system which directs the beam into a dump when a failure is detected. Due to the high current of the beams, the beam kick is tapered from 100% to 80% in 7.33 {micro}S (the beam transit time aroundmore » the ring). This taper distributes the energy evenly across the window which separates the ring from the beam dump such that the window is not damaged. The abort kicker trigger is synchronized with the ion clearing gap of the beam allowing for the kicker field to rise from 0-80% while there is no beam in the kicker magnet. Originally the kicker system was designed for a rise time of 370nS [1], but because the ion clearing gap was reduced in half, so was the rise time requirement for the kicker. This report discusses the design of the system interlocks, diagnostics, and modulator with the modifications necessary to accommodate an ion clearing gap of 185nS.« less
A zone-specific fish-based biotic index as a management tool for the Zeeschelde estuary (Belgium).
Breine, Jan; Quataert, Paul; Stevens, Maarten; Ollevier, Frans; Volckaert, Filip A M; Van den Bergh, Ericia; Maes, Joachim
2010-07-01
Fish-based indices monitor changes in surface waters and are a valuable aid in communication by summarising complex information about the environment (Harrison and Whitfield, 2004). A zone-specific fish-based multimetric estuarine index of biotic integrity (Z-EBI) was developed based on a 13 year time series of fish surveys from the Zeeschelde estuary (Belgium). Sites were pre-classified using indicators of anthropogenic impact. Metrics showing a monotone response with pressure classes were selected for further analysis. Thresholds for the good ecological potential (GEP) were defined from references. A modified trisection was applied for the other thresholds. The Z-EBI is defined by the average of the metric scores calculated over a one year period and translated into an ecological quality ratio (EQR). The indices integrate structural and functional qualities of the estuarine fish communities. The Z-EBI performances were successfully validated for habitat degradation in the various habitat zones. Copyright 2010 Elsevier Ltd. All rights reserved.
Sohng, Hee Yon; Kuniyuki, Alan; Edelson, Jane; Weir, Rosy Chang; Song, Hui; Tu, Shin-Ping
2013-01-01
Understanding and enhancing change capabilities, including Practice Adaptive Reserve (PAR), of Community Health Centers (CHCs) may mitigate cancer-related health disparities. Using stratified random sampling, we recruited 232 staff from seven CHCs serving Asian Pacific Islander communities to complete a self-administered survey. We performed multilevel regression analyses to examine PAR composite scores by CHC, position type, and number of years worked at their clinic. The mean PAR score was 0.7 (s.d. 0.14). Higher scores were associated with a greater perceived likelihood that clinic staff would participate in an evidence-based intervention (EBI). Constructs such as communication, clinic flow, sensemaking, change valence, and resource availability were positively associated with EBI implementation or trended toward significance. PAR scores are positively associated with perceived likelihood of clinic staff participation in cancer screening EBI. Future research is needed to determine PAR levels most conducive to implementing change and to developing interventions that enhance Adaptive Reserve.
Study of the Dynamics of Transcephalic Cerebral Impedance Data during Cardio-Vascular Surgery
NASA Astrophysics Data System (ADS)
Atefi, S. R.; Seoane, F.; Lindecrantz, K.
2013-04-01
Postoperative neurological deficits are one of the risks associated with cardio vascular surgery, necessitating development of new techniques for cerebral monitoring. In this study an experimental observation regarding the dynamics of transcephalic Electrical Bioimpedance (EBI) in patients undergoing cardiac surgery with and without extracorporeal circulation (ECC) was conducted to investigate the potential use of electrical Bioimpedance for cerebral monitoring in cardio vascular surgery. Tetrapolar transcephalic EBI measurements at single frequency of 50 kHz were recorded prior to and during cardio vascular surgery. The obtained results show that the transcephalic impedance decreases in both groups of patients as operation starts, however slight differences in these two groups were also observed with the cerebral impedance reduction in patients having no ECC being less common and not as pronounced as in the ECC group. Changes in the cerebral impedance were in agreement with changes of haematocrit and temperature. The origin of EBI changes is still unexplained however these results encourage us to continue investigating the application of electrical bioimpedance cerebral monitoring clinically.
Holt, Cheryl L; Graham-Phillips, Anita L; Daniel Mullins, C; Slade, Jimmie L; Savoy, Alma; Carter, Roxanne
2017-01-01
African American faith-based organizations (FBOs) play an important role in addressing health disparities. Increasingly, churches offer health fairs, screenings, or education through health ministries. However, little is known about linking these organizations with evidence-based interventions (EBIs) developed by research. This study explored 1) factors that facilitate or impede health ministry activities, including the adoption of EBIs, and 2) opportunities to use technology to support/enhance the capacity of FBOs to sustain health-related activities. We conducted 18 key informant interviews with African American pastors and FBO leaders and six focus groups with members. A popular health ministry strategy was distribution of print materials. There was limited awareness of EBIs and how to access them. Challenges included maintaining qualified volunteers, financial resources, and technical assistance needs. Participants used technology and social media but older adults did so less often. Findings have implications for dissemination/implementation research in FBOs, in relation to the translational continuum.
A Study of Single Pass Ion Effects at the ALS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Byrd, J.M.; Thomson, J.; /LBL, Berkeley
2011-09-13
We report the results of experiments on a 'fast beam-ion instability' at the Advanced Light Source (ALS). This ion instability, which can arise even when the ions are not trapped over multiple beam passages, will likely be important for many future accelerators. In our experiments, we filled the ALS storage ring with helium gas, raising the pressure approximately two orders of magnitude above the nominal pressure. With gaps in the bunch train large enough to avoid conventional (multi-turn) ion trapping, we observed a factor of 2-3 increase in the vertical beam size along with coherent beam oscillations which increased alongmore » the bunch train. Ion trapping has long been recognized as a potential limitation in electron storage rings. The ions, generated by beam-gas collisions, become trapped in the negative potential of the beam and accumulate over multiple beam passages. The trapped ions are then observed to cause a number of deleterious effects such as an increasing beam phase space, a broadening and shifting of the beam transverse oscillation frequencies (tunes), collective beam instabilities, and beam lifetime reductions. All of these effects are of concern for the next generation of accelerators, such as the B-factories or damping rings for future linear colliders, which will store high beam currents with closely spaced bunches and ultra-low beam emittances. One of the standard solutions used to prevent ion trapping is to include a gap in the bunch train which is long compared to the bunch spacing. In this case, the ions are first strongly-focused by the passing electron bunches and then over-focused in the gap. With a sufficiently large gap, the ions can be driven to large amplitudes where they form a diffuse halo and do not affect the beam. In this paper, we describe experiments that study a new regime of transient ion instabilities predicted to arise in future electron storage rings, and linacs with bunch trains. These future rings and linacs, which will be operated with higher beam currents, small transverse beam emittances, and long bunch trains, will use ion clearing gaps to prevent conventional ion trapping. But, while the ion clearing gap may suppress the conventional ion instabilities, it will not suppress a transient beam-ion instability where ions generated and trapped during the passage of a single train lead to a fast instability. While both conventional and transient ion instabilities have the same origin, namely ions produced by the beam, they have different manifestations and, more importantly, the new transient instability can arise even after the conventional ion instability is cured. This new instability is called the 'Fast Beam-Ion Instability' (FBII). In many future rings, the FBII is predicted to have very fast growth rates, much faster than the damping rates of existing and proposed transverse feedback systems, and thus is a potential limitation. To study the FBII, we performed experiments at the ALS, a 1.5 GeV electron storage ring. At the nominal ALS pressure of about 0.24 nTorr, the FBII is not evident. To study the instability, we intentionally added helium gas to the storage-ring vacuum system until the residual gas pressure was increased about 80 nTorr. This brought the predicted growth rate of the instability at least an order of magnitude above the growth rate of conventional multibunch instabilities driven by the RF cavities and above the damping rate of the transverse feedback system (TFB) in the ALS and, thereby, established conditions very similar to those in a future storage ring. We then filled the ring with a relatively short train of bunches, suppressing conventional ion instabilities. In the following, we will first briefly describe This paper describes the experiment and results in more detail.« less
Zhang, Tingting; Su, Jingyuan; Guo, Bingyu; Wang, Kaiwen; Li, Xiaoming; Liang, Guobiao
2015-09-01
Early brain injury (EBI) following subarachnoid hemorrhage (SAH) is associated with high morbidity and mortality. Inflammation has been considered as the major contributor to brain damage after SAH. SAH induces a systemic increase in pro-inflammatory cytokines and chemokines. Disruption of blood-brain barrier (BBB) facilitates the influx of inflammatory cells. It has been reported that the activation of toll-like receptor 4 (TLR4)/NF-κB signaling pathway plays a vital role in the central nervous system diseases. Apigenin, a common plant flavonoid, possesses anti-inflammation effect. In this study, we focused on the effects of apigenin on EBI following SAH and its anti-inflammation mechanism. Our results showed that apigenin (20mg/kg) administration significantly attenuated EBI (including brain edema, BBB disruption, neurological deficient, severity of SAH, and cell apoptosis) after SAH in rats by suppressing the expression of TLR4, NF-κB and their downstream pro-inflammatory cytokines in the cortex and by up-regulating the expression of tight junction proteins of BBB. Double immunofluorescence staining demonstrated that TLR4 was activated following SAH in neurons, microglia cells, and endothelial cells but not in astrocytes. Apigenin could suppress the activation of TLR4 induced by SAH and inhibit apoptosis of cells in the cortex. These results suggested that apigenin could attenuate EBI after SAH in rats by suppressing TLR4-mediated inflammation and protecting against BBB disruption. Copyright © 2015 Elsevier B.V. All rights reserved.
The student experience of applied equivalence-based instruction for neuroanatomy teaching.
Greville, W James; Dymond, Simon; Newton, Philip M
2016-01-01
Esoteric jargon and technical language are potential barriers to the teaching of science and medicine. Effective teaching strategies which address these barriers are desirable. Here, we created and evaluated the effectiveness of stand-alone 'equivalence-based instruction' (EBI) learning resources wherein the teaching of a small number of direct relationships between stimuli (e.g., anatomical regions, their function, and pathology) results in the learning of higher numbers of untaught relationships. We used a pre and post test design to assess students' learning of the relations. Resources were evaluated by students for perceived usefulness and confidence in the topic. Three versions of the resources were designed, to explore learning parameters such as the number of stimulus classes and the number of relationships within these classes. We show that use of EBI resulted in demonstrable learning of material that had not been directly taught. The resources were well received by students, even when the quantity of material to be learned was high. There was a strong desire for more EBI-based teaching. The findings are discussed in the context of an ongoing debate surrounding 'rote' vs. 'deep' learning, and the need to balance this debate with considerations of cognitive load and esoteric jargon routinely encountered during the study of medicine. These standalone EBI resources were an effective, efficient and well-received method for teaching neuroanatomy to medical students. The approach may be of benefit to other subjects with abundant technical jargon, science and other areas of medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benson, Stephen V.; Derbenev, Yaroslav S.; Douglas, David R.
Jefferson Lab is in the process of designing an electron ion collider with unprecedented luminosity at a 45 GeV center-of-mass energy. This luminosity relies on ion cooling in both the booster and the storage ring of the accelerator complex. The cooling in the booster will use a conventional DC cooler similar to the one at COSY. The high-energy storage ring, operating at a momentum of up to 100 GeV/nucleon, requires novel use of bunched-beam cooling. There are two designs for such a cooler. The first uses a conventional Energy Recovery Linac (ERL) with a magnetized beam while the second usesmore » a circulating ring to enhance both peak and average currents experienced by the ion beam. This presentation will describe the design of both the Circulator Cooling Ring (CCR) design and that of the backup option using the stand-alone ERL operated at lower charge but higher repetition rate than the ERL injector required by the CCR-based design.« less
NASA Astrophysics Data System (ADS)
Tomasik, Janice Hall
The plastics industry has been revolutionalized by development of group 4 metallocene polymerization catalysts. These catalysts have higher activities and stereoselectivities than traditional heterogeneous Ziegler-Natta polymerization catalysts, and produce polymers with narrower molecular weight distributions and with better control of the polymer stereochemistry. The reaction kinetics of catalytic alkene polymerizations are complicated and difficult to resolve macroscopically. To overcome these difficulties, research has used NMR spectroscopy to directly observe catalytic reaction intermediates; many advances in our understanding of the complex mechanisms behind these polymerization reactions have resulted. In this work, the direct observation of alkene insertion into zirconocene-polymeryls via NMR spectroscopy is presented. Alkenes studied are 3-methylpentene, styrene, and 1,4-pentadiene. Kinetic measurements are reported for the polymerization of 3-methylpentene by rac-(EBI)Zr(Me)(MeB(C6F 5)3) (EBI = C2H4(1-indenyl)2) and rac-(EBI)Zr(polyhexenyl)(MeB(C6F5) 3). Also presented are NMR spectroscopic characterizations of rac-(EBI)Zr(styrenyl)(MeB(C6F5)3) and rac-(EBI)Zr(1,4-pentadienyl)(MeB(C6F 5)3). In addition, NMR spectroscopy is used to directly monitor the behavior of an aluminum alkyl during the polymerization of 1-hexene by rac -(EBI)2Zr(Me)(MeB(C6F5)3). The rates of polymerization are not inhibited by Al(iBu) 2(BHT), Al(Me)(BHT)2, or Al(iBu)3 (BHT = 2,6-di- tert-butyl-4-methylphenyl). Detailed measurement of polymerization rate and catalyst speciation demonstrate that BHT modified aluminum alkyls protect active sites from decomposition in the presence of protic impurities such as methanol. Also presented in this work is the design and evaluation of an online course for teachers about nanoscience. Nanotechnology is an important emerging field that is estimated to need about 2 million workers worldwide by 2015. Therefore the educational system is being encouraged to incorporate major nanoscience concepts into curricula. In order to facilitate the integration of nanoscience, an online professional development course for teachers has been developed and offered at the University of Wisconsin-Madison. Evaluation results from the first three versions of the course indicate the online learning environment was very close to ideal. Comparisons of pre-instruction to post-instruction quiz responses indicate significant learning gains by participants. Importantly, survey results show the online course helped teachers to successfully incorporate nanoscience into their curricula.
Anderson, Peter; Bendtsen, Preben; Spak, Fredrik; Reynolds, Jillian; Drummond, Colin; Segura, Lidia; Keurhorst, Myrna N; Palacio-Vieira, Jorge; Wojnar, Marcin; Parkinson, Kathryn; Colom, Joan; Kłoda, Karolina; Deluca, Paolo; Baena, Begoña; Newbury-Birch, Dorothy; Wallace, Paul; Heinen, Maud; Wolstenholme, Amy; van Steenkiste, Ben; Mierzecki, Artur; Okulicz-Kozaryn, Katarzyna; Ronda, Gaby; Kaner, Eileen; Laurant, Miranda G H; Coulton, Simon; Gual, Toni
2016-11-01
To test if training and support, financial reimbursement and option of referring screen-positive patients to an internet-based method of giving advice (eBI) can increase primary health-care providers' delivery of Alcohol Use Disorders Identification Test (AUDIT)-C-based screening and advice to heavy drinkers. Cluster randomized factorial trial with 12-week implementation and measurement period. Primary health-care units (PHCU) in different locations throughout Catalonia, England, the Netherlands, Poland and Sweden. A total of 120 PHCU, 24 in each of Catalonia, England, the Netherlands, Poland and Sweden. PHCUs were randomized to one of eight groups: care as usual, training and support (TS), financial reimbursement (FR) and eBI; paired combinations of TS, FR and eBI, and all of FR, TS and eBI. The primary outcome measure was the proportion of eligible adult (age 18+ years) patients screened during a 12-week implementation period. Secondary outcome measures were proportion of screen-positive patients advised; and proportion of consulting adult patients given an intervention (screening and advice to screen-positives) during the same 12-week implementation period. During a 4-week baseline measurement period, the proportion of consulting adult patients who were screened for their alcohol consumption was 0.059 per PHCU (95% CI 0.034 to 0.084). Based on the factorial design, the ratio of the logged proportion screened during the 12-week implementation period was 1.48 (95% CI = 1.13-1.95) in PHCU that received TS versus PHCU that did not receive TS; for FR, the ratio was 2.00 (95% CI = 1.56-2.56). The option of referral to eBI did not lead to a higher proportion of patients screened. The ratio for TS plus FR was 2.34 (95% CI = 1.77-3.10), and the ratio for TS plus FR plus eBI was1.68 (95% CI = 1.11-2.53). Providing primary health-care units with training, support and financial reimbursement for delivering Alcohol Use Disorders Identification Test-C-based screening and advice to heavy drinkers increases screening for alcohol consumption. Providing primary health-care units with the option of referring screen-positive patients to an internet-based method of giving advice does not appear to increase screening for alcohol consumption. © 2016 Society for the Study of Addiction.
Resonant neutral-particle emission in collisions of electrons with peptide ions in a storage ring.
Tanabe, T; Noda, K; Saito, M; Lee, S; Ito, Y; Takagi, H
2003-05-16
Electron-biomolecular ion collisions were studied using an electrostatic storage ring with a merging beam technique for singly protonated peptides (angiotensin I, II, and III). A strong neutral-particle emission at around 6.5 eV was found in addition to neutrals from recombination at low energies. The rates of the high-energy peak greatly decreased with a slight decrease in the number of amino-acid residues from angiotensin I to III. These results suggest that some peptide bonds were selectively cleaved.
Commissioning and Early Operation Experience of the NSLS-II Storage Ring RF System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, F.; Rose, J.; Cupolo, J.
2015-05-03
The National Synchrotron Light Source II (NSLS-II) is a 3 GeV electron X-ray user facility commissioned in 2014. The storage ring RF system, essential for replenishing energy loss per turn of the electrons, consists of digital low level RF controllers, 310 kW CW klystron transmitters, CESR-B type superconducting cavities, as well as a supporting cryogenic system. Here we will report on RF commissioning and early operation experience of the system for beam current up to 200mA.
Mass Measurements of Proton-rich Nuclides at the Cooler Storage Ring at IMP
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Y. H.; Xu, H. S.; Wang, M.
2011-11-30
Recent results and progress of mass measurements of proton-rich nuclei using isochronous mass spectrometry (IMS) are reported. The nuclei under investigation were produced via fragmentation of relativistic energy heavy ions of {sup 78}Kr and {sup 58}Ni. After in-flight separation by the fragment separator RIBLL-2, the nuclei were injected and stored in the experimental storage ring CSRe, and their masses were determined from measurements of the revolution times. The impact of these measurements on the stellar nucleosynthesis in the rp-process is discussed.
Conditioning of the vacuum system of the TPS storage ring without baking in situ
NASA Astrophysics Data System (ADS)
Chan, C. K.; Chang, C. C.; Shueh, C.; Yang, I. C.; Wu, L. H.; Chen, B. Y.; Cheng, C. M.; Huang, Y. T.; Chuang, J. Y.; Cheng, Y. T.; Hsiao, Y. M.; Sheng, Albert
2017-04-01
To shorten the machine downtime, a maintenance procedure without baking in situ has been developed and applied to maintain and to upgrade the vacuum system of the TPS storage ring. The data of photon-stimulated desorption (PSD) reveal no obvious discrepancy between baking and not baking the vacuum system in situ. A beam-conditioning dose of extent only 11.8 A h is required to recover quickly the dynamic pressure of an unbaked vacuum system to its pre-intervention value according to the TPS maintenance experience.
Carvalho, Luiz Jcb; Agustini, Marco Av; Anderson, James V; Vieira, Eduardo A; de Souza, Claudia Rb; Chen, Songbi; Schaal, Barbara A; Silva, Joseane P
2016-06-10
Cassava (Manihot esculenta Crantz) storage root provides a staple food source for millions of people worldwide. Increasing the carotenoid content in storage root of cassava could provide improved nutritional and health benefits. Because carotenoid accumulation has been associated with storage root color, this study characterized carotenoid profiles, and abundance of key transcripts associated with carotenoid biosynthesis, from 23 landraces of cassava storage root ranging in color from white-to-yellow-to-pink. This study provides important information to plant breeding programs aimed at improving cassava storage root nutritional quality. Among the 23 landraces, five carotenoid types were detected in storage root with white color, while carotenoid types ranged from 1 to 21 in storage root with pink and yellow color. The majority of storage root in these landraces ranged in color from pale-to-intense yellow. In this color group, total β-carotene, containing all-E-, 9-Z-, and 13-Z-β-carotene isomers, was the major carotenoid type detected, varying from 26.13 to 76.72 %. Although no α-carotene was observed, variable amounts of a α-ring derived xanthophyll, lutein, was detected; with greater accumulation of α-ring xanthophylls than of β-ring xanthophyll. Lycopene was detected in a landrace (Cas51) with pink color storage root, but it was not detected in storage root with yellow color. Based on microarray and qRT-PCR analyses, abundance of transcripts coding for enzymes involved in carotenoid biosynthesis were consistent with carotenoid composition determined by contrasting HPLC-Diode Array profiles from storage root of landraces IAC12, Cas64, and Cas51. Abundance of transcripts encoding for proteins regulating plastid division were also consistent with the observed differences in total β-carotene accumulation. Among the 23 cassava landraces with varying storage root color and diverse carotenoid types and profiles, landrace Cas51 (pink color storage root) had low LYCb transcript abundance, whereas landrace Cas64 (intense yellow storage root) had decreased HYb transcript abundance. These results may explain the increased amounts of lycopene and total β-carotene observed in landraces Cas51 and Cas64, respectively. Overall, total carotenoid content in cassava storage root of color class representatives were associated with spatial patterns of secondary growth, color, and abundance of transcripts linked to plastid division. Finally, a partial carotenoid biosynthesis pathway is proposed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Billing, M. G.; Conway, J. V.; Crittenden, J. A.
Cornell's electron/positron storage ring (CESR) was modified over a series of accelerator shutdowns beginning in May 2008, which substantially improves its capability for research and development for particle accelerators. CESR's energy span from 1.8 to 5.6 GeV with both electrons and positrons makes it ideal for the study of a wide spectrum of accelerator physics issues and instrumentation related to present light sources and future lepton damping rings. Additionally a number of these are also relevant for the beam physics of proton accelerators. This paper is the third in a series of four describing the conversion of CESR to themore » test accelerator, CESRTA. The first two papers discuss the overall plan for the conversion of the storage ring to an instrument capable of studying advanced accelerator physics issues [1] and the details of the vacuum system upgrades [2]. This paper focuses on the necessary development of new instrumentation, situated in four dedicated experimental regions, capable of studying such phenomena as electron clouds (ECs) and methods to mitigate EC effects. The fourth paper in this series describes the vacuum system modifications of the superconducting wigglers to accommodate the diagnostic instrumentation for the study of EC behavior within wigglers. Lastly, while the initial studies of CESRTA focused on questions related to the International Linear Collider damping ring design, CESRTA is a very versatile storage ring, capable of studying a wide range of accelerator physics and instrumentation questions.« less
Billing, M. G.; Conway, J. V.; Crittenden, J. A.; ...
2016-04-28
Cornell's electron/positron storage ring (CESR) was modified over a series of accelerator shutdowns beginning in May 2008, which substantially improves its capability for research and development for particle accelerators. CESR's energy span from 1.8 to 5.6 GeV with both electrons and positrons makes it ideal for the study of a wide spectrum of accelerator physics issues and instrumentation related to present light sources and future lepton damping rings. Additionally a number of these are also relevant for the beam physics of proton accelerators. This paper is the third in a series of four describing the conversion of CESR to themore » test accelerator, CESRTA. The first two papers discuss the overall plan for the conversion of the storage ring to an instrument capable of studying advanced accelerator physics issues [1] and the details of the vacuum system upgrades [2]. This paper focuses on the necessary development of new instrumentation, situated in four dedicated experimental regions, capable of studying such phenomena as electron clouds (ECs) and methods to mitigate EC effects. The fourth paper in this series describes the vacuum system modifications of the superconducting wigglers to accommodate the diagnostic instrumentation for the study of EC behavior within wigglers. Lastly, while the initial studies of CESRTA focused on questions related to the International Linear Collider damping ring design, CESRTA is a very versatile storage ring, capable of studying a wide range of accelerator physics and instrumentation questions.« less
A 1kW EUV source for lithography based on FEL emission in a compact storage ring
NASA Astrophysics Data System (ADS)
Feser, Michael; Ruth, Ron; Loewen, Rod
2017-10-01
EUV has long been hailed as the next generation lithography technology. Its adoption into high volume manufacturing (HVM), however, has been delayed several technology nodes due to technical issues, many of which can be attributed to the EUV source performance. Today's EUV lithography scanners are powered by laser produce plasma (LPP) sources. They have issues with power scaling beyond 300 W, reliability and contamination. Free Electron Lasers (FELs) have been considered as an alternative EUV source. Advantages of accelerator based sources are the maturity of the accelerator technology, lack of debris/contamination, and ability to provide high power. Industry turned away from this technology because of the requirement to feed up to 10 scanners from one linear FEL to make it economically feasible, the large footprint, and generation of radioactive byproducts. All of these issues are overcome in the presented concept using a compact storage ring with steady-state FEL lasing action. At 1 kW output power, comparable cost and footprint to an LPP source, this source is ideally suited for use on a single scanner and promises reliable, contamination free operation. FEL action in the storage ring is sustained by operating the FEL well below the saturation regime and preserving the equilibrium low emittance and energy distribution of the ring.
Measurement techniques for low emittance tuning and beam dynamics at CESR
NASA Astrophysics Data System (ADS)
Billing, M. G.; Dobbins, J. A.; Forster, M. J.; Kreinick, D. L.; Meller, R. E.; Peterson, D. P.; Ramirez, G. A.; Rendina, M. C.; Rider, N. T.; Sagan, D. C.; Shanks, J.; Sikora, J. P.; Stedinger, M. G.; Strohman, C. R.; Williams, H. A.; Palmer, M. A.; Holtzapple, R. L.; Flanagan, J.
2018-03-01
After operating as a High Energy Physics electron-positron collider, the Cornell Electron-positron Storage Ring (CESR) has been converted to become a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS). Over the course of several years CESR was adapted for accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Initially some specific topics were targeted for accelerator physic research with the storage ring in this mode, labeled CesrTA. These topics included 1) tuning techniques to produce low emittance beams, 2) the study of electron cloud (EC) development in a storage ring and 3) intra-beam scattering effects. The complete conversion of CESR to CesrTA occurred over a several year period, described elsewhere [1–3]. A number of specific instruments were developed for CesrTA. Much of the pre-existing instrumentation was modified to accommodate the scope of these studies and these are described in a companion paper [4]. To complete this research, a number of procedures were developed or modified, often requiring coordinated measurements among different instruments [5]. This paper provides an overview of types of measurements employed for the study of beam dynamics during the operation of CesrTA.
Beam measurements using visible synchrotron light at NSLS2 storage ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, Weixing, E-mail: chengwx@bnl.gov; Bacha, Bel; Singh, Om
2016-07-27
Visible Synchrotron Light Monitor (SLM) diagnostic beamline has been designed and constructed at NSLS2 storage ring, to characterize the electron beam profile at various machine conditions. Due to the excellent alignment, SLM beamline was able to see the first visible light when beam was circulating the ring for the first turn. The beamline has been commissioned for the past year. Besides a normal CCD camera to monitor the beam profile, streak camera and gated camera are used to measure the longitudinal and transverse profile to understand the beam dynamics. Measurement results from these cameras will be presented in this paper.more » A time correlated single photon counting system (TCSPC) has also been setup to measure the single bunch purity.« less
Using EMBL-EBI services via Web interface and programmatically via Web Services
Lopez, Rodrigo; Cowley, Andrew; Li, Weizhong; McWilliam, Hamish
2015-01-01
The European Bioinformatics Institute (EMBL-EBI) provides access to a wide range of databases and analysis tools that are of key importance in bioinformatics. As well as providing Web interfaces to these resources, Web Services are available using SOAP and REST protocols that enable programmatic access to our resources and allow their integration into other applications and analytical workflows. This unit describes the various options available to a typical researcher or bioinformatician who wishes to use our resources via Web interface or programmatically via a range of programming languages. PMID:25501941
Charge breeding of radioactive isotopes at the CARIBU facility with an electron beam ion source
NASA Astrophysics Data System (ADS)
Vondrasek, R. C.; Dickerson, C. A.; Hendricks, M.; Ostroumov, P.; Pardo, R.; Savard, G.; Scott, R.; Zinkann, G.
2018-05-01
An Electron Beam Ion Source Charge Breeder (EBIS-CB) has been developed at Argonne National Laboratory as part of the californium rare ion breeder upgrade. For the past year, the EBIS-CB has been undergoing commissioning as part of the ATLAS accelerator complex. It has delivered both stable and radioactive beams with A/Q < 6, breeding times <30 ms, low background contamination, and charge breeding efficiencies >18% into a single charge state. The operation of this device, challenges during the commissioning phase, and future improvements will be discussed.
Advanced Photon Source accelerator ultrahigh vacuum guide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, C.; Noonan, J.
1994-03-01
In this document the authors summarize the following: (1) an overview of basic concepts of ultrahigh vacuum needed for the APS project, (2) a description of vacuum design and calculations for major parts of APS, including linac, linac waveguide, low energy undulator test line, positron accumulator ring (PAR), booster synchrotron ring, storage ring, and insertion devices, and (3) cleaning procedures of ultrahigh vacuum (UHV) components presently used at APS.
Emittance and lifetime measurement with damping wigglers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, G. M.; Shaftan, T., E-mail: shaftan@bnl.gov; Cheng, W. X.
National Synchrotron Light Source II (NSLS-II) is a new third-generation storage ring light source at Brookhaven National Laboratory. The storage ring design calls for small horizontal emittance (<1 nm-rad) and diffraction-limited vertical emittance at 12 keV (8 pm-rad). Achieving low value of the beam size will enable novel user experiments with nm-range spatial and meV-energy resolution. The high-brightness NSLS-II lattice has been realized by implementing 30-cell double bend achromatic cells producing the horizontal emittance of 2 nm rad and then halving it further by using several Damping Wigglers (DWs). This paper is focused on characterization of the DW effects inmore » the storage ring performance, namely, on reduction of the beam emittance, and corresponding changes in the energy spread and beam lifetime. The relevant beam parameters have been measured by the X-ray pinhole camera, beam position monitors, beam filling pattern monitor, and current transformers. In this paper, we compare the measured results of the beam performance with analytic estimates for the complement of the 3 DWs installed at the NSLS-II.« less
Higher-Order Systematic Effects in the Muon Beam-Spin Dynamics for Muon g-2
NASA Astrophysics Data System (ADS)
Crnkovic, Jason; Brown, Hugh; Krouppa, Brandon; Metodiev, Eric; Morse, William; Semertzidis, Yannis; Tishchenko, Vladimir
2016-03-01
The BNL Muon g-2 Experiment (E821) produced a precision measurement of the muon anomalous magnetic moment, where as the Fermilab Muon g-2 Experiment (E989) is an upgraded version of E821 that has a goal of producing a measurement with approximately 4 times more precision. Improving the precision requires a more detailed understanding of the experimental systematic effects, and so three higher-order systematic effects in the muon beam-spin dynamics have recently been found and estimated for E821. The beamline systematic effect originates from muon production in beamline spectrometers, as well as from muons traversing beamline bending magnets. The kicker systematic effect comes from a combination of the variation in time spent inside the muon storage ring across a muon bunch and the temporal structure of the storage ring kicker waveform. Finally, the detector systematic effect arises from a combination of the energy dependent muon equilibrium orbit in the storage ring, muon decay electron drift time, and decay electron detector acceptance effects. Brookhaven Natl Lab.
Kegeles, Susan M; Rebchook, Gregory; Tebbetts, Scott; Arnold, Emily
2015-04-17
Since the scale-up of HIV/AIDS prevention evidence-based interventions (EBIs) has not been simple, it is important to examine processes that occur in the translation of the EBIs into practice that affect successful implementation. The goal of this paper is to examine facilitators and barriers to effective implementation that arose among 72 community-based organizations as they moved into practice a multilevel HIV prevention intervention EBI, the Mpowerment Project, for young gay and bisexual men. CBOs that were implementing the Mpowerment Project participated in this study and were assessed at baseline, and 6-months, 1 year, and 2 years post-baseline. Semi-structured telephone interviews were conducted separately with individuals at each CBO. Study data came from 647 semi-structured interviews and extensive notes and commentaries from technical assistance providers. Framework Analysis guided the analytic process. Barriers and facilitators to implementation was the overarching thematic framework used across all the cases in our analysis. Thirteen themes emerged regarding factors that influence the successful implementation of the MP. These were organized into three overarching themes: HIV Prevention System Factors, Community Factors, and Intervention Factors. The entire HIV Prevention System, including coordinators, supervisors, executive directors, funders, and national HIV prevention policies, all influenced implementation success. Other Prevention System Factors that affected the effective translation of the EBI into practice include Knowledge About Intervention, Belief in the Efficacy of the Intervention, Desire to Change Existing Prevention Approach, Planning for Intervention Before Implementation, Accountability, Appropriateness of Individuals for Coordinator Positions, Evaluation of Intervention, and Organizational Stability. Community Factors included Geography and Sociopolitical Climate. Intervention Factors included Intervention Characteristics and Adaptation Issues. The entire ecological system in which an EBI occurs affects implementation. It is imperative to focus capacity-building efforts on getting individuals at different levels of the HIV Prevention System into alignment regarding understanding and believing in the program's goals and methods. For a Prevention Support System to be maximally useful, it must address facilitators or barriers to implementation, address the right people, and use modalities to convey information that are acceptable for users of the system.
2012-01-01
Background There is a great deal of variation in the existing capacity of primary prevention programs and policies addressing chronic disease to deliver evidence-based interventions (EBIs). In order to develop and evaluate implementation strategies that are tailored to the appropriate level of capacity, there is a need for an easy-to-administer tool to stage organizational readiness for EBIs. Methods Based on theoretical frameworks, including Rogers’ Diffusion of Innovations, we developed a survey instrument to measure four domains representing stages of readiness for EBI: awareness, adoption, implementation, and maintenance. A separate scale representing organizational climate as a potential mediator of readiness for EBIs was also included in the survey. Twenty-three questions comprised the four domains, with four to nine items each, using a seven-point response scale. Representatives from obesity, asthma, diabetes, and tobacco prevention programs serving diverse populations in the United States were surveyed (N = 243); test-retest reliability was assessed with 92 respondents. Results Confirmatory factor analysis (CFA) was used to test and refine readiness scales. Test-retest reliability of the readiness scales, as measured by intraclass correlation, ranged from 0.47–0.71. CFA found good fit for the five-item adoption and implementation scales and resulted in revisions of the awareness and maintenance scales. The awareness scale was split into two two-item scales, representing community and agency awareness. The maintenance scale was split into five- and four-item scales, representing infrastructural maintenance and evaluation maintenance, respectively. Internal reliability of scales (Cronbach’s α) ranged from 0.66–0.78. The model for the final revised scales approached good fit, with most factor loadings >0.6 and all >0.4. Conclusions The lack of adequate measurement tools hinders progress in dissemination and implementation research. These preliminary results help fill this gap by describing the reliability and measurement properties of a theory-based tool; the short, user-friendly instrument may be useful to researchers and practitioners seeking to assess organizational readiness for EBIs across a variety of chronic disease prevention programs and settings. PMID:22800294
Stamatakis, Katherine A; McQueen, Amy; Filler, Carl; Boland, Elizabeth; Dreisinger, Mariah; Brownson, Ross C; Luke, Douglas A
2012-07-16
There is a great deal of variation in the existing capacity of primary prevention programs and policies addressing chronic disease to deliver evidence-based interventions (EBIs). In order to develop and evaluate implementation strategies that are tailored to the appropriate level of capacity, there is a need for an easy-to-administer tool to stage organizational readiness for EBIs. Based on theoretical frameworks, including Rogers' Diffusion of Innovations, we developed a survey instrument to measure four domains representing stages of readiness for EBI: awareness, adoption, implementation, and maintenance. A separate scale representing organizational climate as a potential mediator of readiness for EBIs was also included in the survey. Twenty-three questions comprised the four domains, with four to nine items each, using a seven-point response scale. Representatives from obesity, asthma, diabetes, and tobacco prevention programs serving diverse populations in the United States were surveyed (N=243); test-retest reliability was assessed with 92 respondents. Confirmatory factor analysis (CFA) was used to test and refine readiness scales. Test-retest reliability of the readiness scales, as measured by intraclass correlation, ranged from 0.47-0.71. CFA found good fit for the five-item adoption and implementation scales and resulted in revisions of the awareness and maintenance scales. The awareness scale was split into two two-item scales, representing community and agency awareness. The maintenance scale was split into five- and four-item scales, representing infrastructural maintenance and evaluation maintenance, respectively. Internal reliability of scales (Cronbach's α) ranged from 0.66-0.78. The model for the final revised scales approached good fit, with most factor loadings >0.6 and all >0.4. The lack of adequate measurement tools hinders progress in dissemination and implementation research. These preliminary results help fill this gap by describing the reliability and measurement properties of a theory-based tool; the short, user-friendly instrument may be useful to researchers and practitioners seeking to assess organizational readiness for EBIs across a variety of chronic disease prevention programs and settings.
Surface and material analytics based on Dresden-EBIS platform technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmidt, M., E-mail: mike.schmidt@dreebit.com; König, J., E-mail: mike.schmidt@dreebit.com; Bischoff, L.
2015-01-09
Nowadays widely used mass spectrometry systems utilize energetic ions hitting a sample and sputter material from the surface of a specimen. The generated secondary ions are separated and detected with high mass resolution to determine the target materials constitution. Based on this principle, we present an alternative approach implementing a compact Electron Beam Ion Source (EBIS) in combination with a Liquid Metal Ion Source (LMIS). An LMIS can deliver heavy elements which generate high sputter yields on a target surface. More than 90% of this sputtered material consists of mono- and polyatomic neutrals. These particles are able to penetrate themore » magnetic field of an EBIS and they will be ionized within the electron beam. A broad spectrum of singly up to highly charged ions can be extracted depending on the operation conditions. Polyatomic ions will decay during the charge-up process. A standard bending magnet or a Wien filter is used to separate the different ion species due to their mass-to-charge ratio. Using different charge states of ions as it is common with EBIS it is also possible to resolve interfering charge-to-mass ratios of only singly charged ions. Different setups for the realization of feeding the electron beam with sputtered atoms of solids will be presented and discussed. As an example the analysis of a copper surface is used to show high-resolution spectra with low background noise. Individual copper isotopes and clusters with different isotope compositions can be resolved at equal atomic numbers. These results are a first step for the development of a new compact low-cost and high-resolution mass spectrometry system. In a more general context, the described technique demonstrates an efficient method for feeding an EBIS with atoms of nearly all solid elements from various solid target materials. The new straightforward design of the presented setup should be of high interest for a broad range of applications in materials research as well as for applications connected to analyzing the biosphere, hydrosphere, lithosphere, cosmosphere and technosphere.« less
The student experience of applied equivalence-based instruction for neuroanatomy teaching
2016-01-01
Purpose Esoteric jargon and technical language are potential barriers to the teaching of science and medicine. Effective teaching strategies which address these barriers are desirable. Here, we created and evaluated the effectiveness of stand-alone ‘equivalence-based instruction’ (EBI) learning resources wherein the teaching of a small number of direct relationships between stimuli (e.g., anatomical regions, their function, and pathology) results in the learning of higher numbers of untaught relationships. Methods We used a pre and post test design to assess students’ learning of the relations. Resources were evaluated by students for perceived usefulness and confidence in the topic. Three versions of the resources were designed, to explore learning parameters such as the number of stimulus classes and the number of relationships within these classes. Results We show that use of EBI resulted in demonstrable learning of material that had not been directly taught. The resources were well received by students, even when the quantity of material to be learned was high. There was a strong desire for more EBI-based teaching. The findings are discussed in the context of an ongoing debate surrounding ‘rote’ vs. ‘deep’ learning, and the need to balance this debate with considerations of cognitive load and esoteric jargon routinely encountered during the study of medicine. Conclusion These standalone EBI resources were an effective, efficient and well-received method for teaching neuroanatomy to medical students. The approach may be of benefit to other subjects with abundant technical jargon, science and other areas of medicine. PMID:27649900
The RNASeq-er API-a gateway to systematically updated analysis of public RNA-seq data.
Petryszak, Robert; Fonseca, Nuno A; Füllgrabe, Anja; Huerta, Laura; Keays, Maria; Tang, Y Amy; Brazma, Alvis
2017-07-15
The exponential growth of publicly available RNA-sequencing (RNA-Seq) data poses an increasing challenge to researchers wishing to discover, analyse and store such data, particularly those based in institutions with limited computational resources. EMBL-EBI is in an ideal position to address these challenges and to allow the scientific community easy access to not just raw, but also processed RNA-Seq data. We present a Web service to access the results of a systematically and continually updated standardized alignment as well as gene and exon expression quantification of all public bulk (and in the near future also single-cell) RNA-Seq runs in 264 species in European Nucleotide Archive, using Representational State Transfer. The RNASeq-er API (Application Programming Interface) enables ontology-powered search for and retrieval of CRAM, bigwig and bedGraph files, gene and exon expression quantification matrices (Fragments Per Kilobase Of Exon Per Million Fragments Mapped, Transcripts Per Million, raw counts) as well as sample attributes annotated with ontology terms. To date over 270 00 RNA-Seq runs in nearly 10 000 studies (1PB of raw FASTQ data) in 264 species in ENA have been processed and made available via the API. The RNASeq-er API can be accessed at http://www.ebi.ac.uk/fg/rnaseq/api . The commands used to analyse the data are available in supplementary materials and at https://github.com/nunofonseca/irap/wiki/iRAP-single-library . rnaseq@ebi.ac.uk ; rpetry@ebi.ac.uk. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.
The magnetic toroidal sector: a broad-band electron-positron pair spectrometer
NASA Astrophysics Data System (ADS)
Hagmann, Siegbert; Hillenbrand, Pierre-Michel; Litvinov, Yuri; Spillmann, Uwe
2016-05-01
At the future relativistic storage-ring HESR at FAIR the study of electron-positron pairs from non-nuclear, atomic processes will be one of the goals of the experimental program with kinematically complete experiments focusing on momentum spectroscopy of coincident emission of electrons and positrons from free-free pairs and corresponding recoil ions. The underlying production mechanisms belong to central topics of QED in strong fields. We present first results on the electron-optical properties of a magnetic toroidal sector configuration enabling coincident detection of free-free electron-positron pairs; this spectrometer is suitable for implementation into a storage ring with a supersonic jet target and covering a wide range of lepton emission into the forward hemisphere. The simulation calculations are performed using the OPERA code.
The annotation-enriched non-redundant patent sequence databases.
Li, Weizhong; Kondratowicz, Bartosz; McWilliam, Hamish; Nauche, Stephane; Lopez, Rodrigo
2013-01-01
The EMBL-European Bioinformatics Institute (EMBL-EBI) offers public access to patent sequence data, providing a valuable service to the intellectual property and scientific communities. The non-redundant (NR) patent sequence databases comprise two-level nucleotide and protein sequence clusters (NRNL1, NRNL2, NRPL1 and NRPL2) based on sequence identity (level-1) and patent family (level-2). Annotation from the source entries in these databases is merged and enhanced with additional information from the patent literature and biological context. Corrections in patent publication numbers, kind-codes and patent equivalents significantly improve the data quality. Data are available through various user interfaces including web browser, downloads via FTP, SRS, Dbfetch and EBI-Search. Sequence similarity/homology searches against the databases are available using BLAST, FASTA and PSI-Search. In this article, we describe the data collection and annotation and also outline major changes and improvements introduced since 2009. Apart from data growth, these changes include additional annotation for singleton clusters, the identifier versioning for tracking entry change and the entry mappings between the two-level databases. Database URL: http://www.ebi.ac.uk/patentdata/nr/
The Annotation-enriched non-redundant patent sequence databases
Li, Weizhong; Kondratowicz, Bartosz; McWilliam, Hamish; Nauche, Stephane; Lopez, Rodrigo
2013-01-01
The EMBL-European Bioinformatics Institute (EMBL-EBI) offers public access to patent sequence data, providing a valuable service to the intellectual property and scientific communities. The non-redundant (NR) patent sequence databases comprise two-level nucleotide and protein sequence clusters (NRNL1, NRNL2, NRPL1 and NRPL2) based on sequence identity (level-1) and patent family (level-2). Annotation from the source entries in these databases is merged and enhanced with additional information from the patent literature and biological context. Corrections in patent publication numbers, kind-codes and patent equivalents significantly improve the data quality. Data are available through various user interfaces including web browser, downloads via FTP, SRS, Dbfetch and EBI-Search. Sequence similarity/homology searches against the databases are available using BLAST, FASTA and PSI-Search. In this article, we describe the data collection and annotation and also outline major changes and improvements introduced since 2009. Apart from data growth, these changes include additional annotation for singleton clusters, the identifier versioning for tracking entry change and the entry mappings between the two-level databases. Database URL: http://www.ebi.ac.uk/patentdata/nr/ PMID:23396323
Non-invasive method for the aortic blood pressure waveform estimation using the measured radial EBI
NASA Astrophysics Data System (ADS)
Krivoshei, Andrei; Lamp, Jürgen; Min, Mart; Uuetoa, Tiina; Uuetoa, Hasso; Annus, Paul
2013-04-01
The paper presents a method for the Central Aortic Pressure (CAP) waveform estimation from the measured radial Electrical Bio-Impedance (EBI). The method proposed here is a non-invasive and health-safe approach to estimate the cardiovascular system parameters, such as the Augmentation Index (AI). Reconstruction of the CAP curve from the EBI data is provided by spectral domain transfer functions (TF), found on the bases of data analysis. Clinical experiments were carried out on 30 patients in the Center of Cardiology of East-Tallinn Central Hospital during coronary angiography on patients in age of 43 to 80 years. The quality and reliability of the method was tested by comparing the evaluated augmentation indices obtained from the invasively measured CAP data and from the reconstructed curve. The correlation coefficient r = 0.89 was calculated in the range of AICAP values from 5 to 28. Comparing to the traditional tonometry based method, the developed one is more convenient to use and it allows long-term monitoring of the AI, what is not possible with tonometry probes.
Charge breeding simulations for radioactive ion beam production
DOE Office of Scientific and Technical Information (OSTI.GOV)
Variale, V.; Raino, A. C.; Clauser, T.
2012-02-15
The charge breeding technique is used for radioactive ion beam (RIB) production in order of optimizing the re-acceleration of the radioactive element ions produced by a primary beam in a thick target. Charge breeding is achieved by means of a device capable of increasing the ion charge state from 1+ to a desired value n+. In order to get high intensity RIB, experiments with charge breeding of very high efficiency could be required. To reach this goal, the charge breeding simulation could help to optimize the high charge state production efficiency by finding more proper parameters for the radioactive 1+more » ions. In this paper a device based on an electron beam ion source (EBIS) is considered. In order to study that problem, a code already developed for studying the ion selective containment in an EBIS with RF quadrupoles, BRICTEST, has been modified to simulate the ion charge state breeding rate for different 1+ ion injection conditions. Particularly, the charge breeding simulations for an EBIS with a hollow electron beam have been studied.« less
The REX-ISOLDE charge breeder as an operational machine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wenander, F.; Delahaye, P.; Scrivens, R.
2006-03-15
The charge breeding system of radioactive beam experiment at ISOLDE (REX-ISOLDE), consisting of a large Penning trap in combination with an electron-beam ion source (EBIS), is now a mature concept after having delivered radioactive beams for postacceleration to a number of experiments for three years. The system, preparing ions prior to injection into a compact linear accelerator, has shown to be versatile in terms of the ion species and energies that can be delivered. During the experimental periods 2004 and 2005 a significant part of the ISOLDE beam time was dedicated to REX-ISOLDE experiments. Ion masses in the range betweenmore » A=7 and 153 have been handled with record efficiencies. High-intensity as well as very-short-lived isotope beams were proven to be feasible. Continuous injection into the EBIS has also been successfully tested. Two means of suppressing unwanted beam contaminations were tested and are now in use. In addition, the experience gained from the trap-EBIS concept from a machine operational point of view will be discussed and the limitations described.« less
3 GeV Booster Synchrotron Conceptual Design Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wiedemann, Helmut
2009-06-02
Synchrotron light cna be produced from a relativistic particle beam circulating in a storage ring at extremely high intensity and brilliance over a large spectral region reaching from the far infrared regime to hard x-rays. The particles, either electrons or positrons, radiate as they are deflected in the fields of the storage ring bending magnets or of magnets specially optimized for the production of synchrotron light. The synchrotron light being very intense and well collimated in the forward direction has become a major tool in a large variety of research fields in physics, chemistry, material science, biology, and medicine.
Safe operating conditions for NSLS-II Storage Ring Frontends commissioning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seletskiy, S.; Amundsen, C.; Ha, K.
2015-04-02
The NSLS-II Storage Ring Frontends are designed to safely accept the synchrotron radiation fan produced by respective insertion device when the electron beam orbit through the ID is locked inside the predefined Active Interlock Envelope. The Active Interlock is getting enabled at a particular beam current known as AI safe current limit. Below such current the beam orbit can be anywhere within the limits of the SR beam acceptance. During the FE commissioning the beam orbit is getting intentionally disturbed in the particular ID. In this paper we explore safe operating conditions for the Frontends commissioning.
DESY II, a new injector for the DESY storage rings PETRA and DORIS II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hemmie, G.
1983-08-01
There is a proposal to build a new 9 GeV electron synchrotron as a dedicated injector for the storage rings DORIS and PETRA. This machine will be housed in the old DESY-tunnel side-by-side with the original DESY-synchrotron. It is characterized by a separated function lattice, a 12.5 Hz repetition frequency, an all-metal vacuum chamber and a high shunt impedance rf-system. After commissioning of this new machine in 1984, the old DESY-synchrotron could be converted into a dedicated proton-accelerator as part of the injection chain for HERA.
Explicit symplectic orbit and spin tracking method for electric storage ring
Hwang, Kilean; Lee, S. Y.
2016-08-18
We develop a symplectic charged particle tracking method for phase space coordinates and polarization in all electric storage rings. Near the magic energy, the spin precession tune is proportional to the fractional momentum deviation δ m from the magic energy, and the amplitude of the radial and longitudinal spin precession is proportional to η/δ m, where η is the electric dipole moment for an initially vertically polarized beam. As a result, the method can be used to extract the electron electric dipole moment of a charged particle by employing narrow band frequency analysis of polarization around the magic energy.
Experience with Round Beam Operation at The Advanced Photon Source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiao, A.; Emery, L.; Sajaev, V.
2015-01-01
Very short Touschek lifetime becomes a common issue for next-generation ultra-low emittance storage ring light sources. In order to reach a longer beamlifetime, such amachine often requires operating with a vertical-to-horizontal emittance ratio close to an unity, i.e. a “round beam”. In tests at the APS storage ring, we determined how a round beam can be reached experimentally. Some general issues, such as beam injection, optics measurement and corrections, and orbit correction have been tested also. To demonstrate that a round beam was achieved, the beam size ratio is calibrated using beam lifetime measurement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yuri, Yosuke, E-mail: yuri.yosuke@jaea.go.jp
Three-dimensional (3D) ordering of a charged-particle beams circulating in a storage ring is systematically studied with a molecular-dynamics simulation code. An ion beam can exhibit a 3D ordered configuration at ultralow temperature as a result of powerful 3D laser cooling. Various unique characteristics of the ordered beams, different from those of crystalline beams, are revealed in detail, such as the single-particle motion in the transverse and longitudinal directions, and the dependence of the tune depression and the Coulomb coupling constant on the operating points.
NASA Astrophysics Data System (ADS)
Bondarevskaya, A.; Prozorov, A.; Labzowsky, L.; Plunien, G.; Liesen, D.; Bosch, F.
2011-10-01
Theoretical concepts for the production, preservation and control of polarized highly charged ion beams in storage rings are investigated. It is argued that hydrogen-like ions can be polarized efficiently by optical pumping of the Zeeman sublevels of ground state hyperfine levels and that the maximum achievable nuclear polarization exceeds 90%. In order to study the preservation of the polarization during the ion motion through the magnetic system of the ring, the concept of the instantaneous quantization axis is introduced. It is suggested that the employment of “Siberian snakes” may help to preserve the ion beam polarization in the ring. The control of the beam polarization can be achieved by different methods: by measuring the Stokes parameters for the emitted photons or by observing the angular dependence of the transition rates for polarized ions. The important motivation for the production of polarized ion beams is the possibility to observe parity nonconservation effects in the hyperfine-quenched transitions in helium-like highly charged ions, where these effects can reach an unprecedented high value for atomic physics. The possible observation of parity nonconservation effects connected with the nuclear anapole moment is also discussed. A method for the observation of the electric dipole moment of an electron in a storage ring with a polarized highly charged ion beam is proposed. This method allows, in principle, to improve the existing boundaries for the electric dipole moment of an electron. However, the requirements of the corresponding experiment are very stringent.
NASA Astrophysics Data System (ADS)
Dye, A.; Alexander, M. R.; Bishop, D.; Pederson, N.; Hessl, A. E.
2016-12-01
Storage of carbon in terrestrial plants and soils directly reduces atmospheric carbon concentration, and it is thereby imperative to improve our understanding of where carbon is being stored and released in an ecosystem and how storages and releases are changing over time. At data-rich sites, coupling alternative measurements of carbon flux can improve this understanding. Here, we present a methodology to inversely model stand-level net storage and release of above- and belowground carbon over a period of 1-2 decades using co-located tree-ring plots and eddy covariance towers at three eastern U.S. forests. We reconstructed annual aboveground wood production (aNPP) from tree rings collected near eddy covariance towers. We compared our aNPP reconstructions with annual tower NEE to address whether interannual variations are correlated. Despite modest correlation, we observed magnitude differences between both records that vary annually. We interpret these differences as indicative of changes in belowground carbon storage, i.e. an aNPP:NEE ratio > 1 indicates a net release of belowground carbon and a ratio < 1 a net storage of belowground carbon. For this interpretation, we assume the following: a) carbon not directed to above or belowground pools is insignificant, b) carbon not stored above ground is stored below ground, and c) mature trees do not add to a storage pool at a higher level every year. While the offset between biometric aNPP and tower NEE could partially be attributed to the diversion of assimilated carbon to nonstructural carbohydrates instead of growth, we argue that this becomes a less important factor over longer time scales in a mature tree. Our approach does not quantify belowground NPP or allocation, but we present a method for estimating belowground carbon storage and release at the stand level, an otherwise difficult task at this scale due to heterogeneity across the stand.
the 29th International Cosmic Ray Conference, Pune India, August 10, 2005 Reactor Searches for Theta Rings, Bombay India, August 2, 2005 NOvA Presentation at the Workshop on Physics of Atmospheric Neutrinos and Neutrinos from Muon Storage Rings, Bombay India, August 2, 2005 The Double Chooz Double Fast
Sc-Decorated Porous Graphene for High-Capacity Hydrogen Storage: First-Principles Calculations.
Chen, Yuhong; Wang, Jing; Yuan, Lihua; Zhang, Meiling; Zhang, Cairong
2017-08-02
The generalized gradient approximation (GGA) function based on density functional theory is adopted to investigate the optimized geometrical structure, electron structure and hydrogen storage performance of Sc modified porous graphene (PG). It is found that the carbon ring center is the most stable adsorbed position for a single Sc atom on PG, and the maximum number of adsorbed H₂ molecules is four with the average adsorption energy of -0.429 eV/H₂. By adding a second Sc atom on the other side of the system, the hydrogen storage capacity of the system can be improved effectively. Two Sc atoms located on opposite sides of the PG carbon ring center hole is the most suitable hydrogen storage structure, and the hydrogen storage capacity reach a maximum 9.09 wt % at the average adsorption energy of -0.296 eV/H₂. The adsorption of H₂ molecules in the PG system is mainly attributed to orbital hybridization among H, Sc, and C atoms, and Coulomb attraction between negatively charged H₂ molecules and positively charged Sc atoms.
Sc-Decorated Porous Graphene for High-Capacity Hydrogen Storage: First-Principles Calculations
Chen, Yuhong; Wang, Jing; Yuan, Lihua; Zhang, Meiling
2017-01-01
The generalized gradient approximation (GGA) function based on density functional theory is adopted to investigate the optimized geometrical structure, electron structure and hydrogen storage performance of Sc modified porous graphene (PG). It is found that the carbon ring center is the most stable adsorbed position for a single Sc atom on PG, and the maximum number of adsorbed H2 molecules is four with the average adsorption energy of −0.429 eV/H2. By adding a second Sc atom on the other side of the system, the hydrogen storage capacity of the system can be improved effectively. Two Sc atoms located on opposite sides of the PG carbon ring center hole is the most suitable hydrogen storage structure, and the hydrogen storage capacity reach a maximum 9.09 wt % at the average adsorption energy of −0.296 eV/H2. The adsorption of H2 molecules in the PG system is mainly attributed to orbital hybridization among H, Sc, and C atoms, and Coulomb attraction between negatively charged H2 molecules and positively charged Sc atoms. PMID:28767084
Electron beam ion source and electron beam ion trap (invited).
Becker, Reinard; Kester, Oliver
2010-02-01
The electron beam ion source (EBIS) and its trap variant [electron beam ion trap (EBIT)] celebrated their 40th and 20th anniversary, respectively, at the EBIS/T Symposium 2007 in Heidelberg. These technologically challenging sources of highly charged ions have seen a broad development in many countries over the last decades. In contrast to most other ion sources the recipe of improvement was not "sorcery" but a clear understanding of the physical laws and obeying the technological constraints. This review will report important achievements of the past as well as promising developments in the future.
Using EMBL-EBI Services via Web Interface and Programmatically via Web Services.
Lopez, Rodrigo; Cowley, Andrew; Li, Weizhong; McWilliam, Hamish
2014-12-12
The European Bioinformatics Institute (EMBL-EBI) provides access to a wide range of databases and analysis tools that are of key importance in bioinformatics. As well as providing Web interfaces to these resources, Web Services are available using SOAP and REST protocols that enable programmatic access to our resources and allow their integration into other applications and analytical workflows. This unit describes the various options available to a typical researcher or bioinformatician who wishes to use our resources via Web interface or programmatically via a range of programming languages. Copyright © 2014 John Wiley & Sons, Inc.
Köcher, Paul; Horna, Viviana; Leuschner, Christoph
2013-08-01
The functional role of internal water storage is increasingly well understood in tropical trees and conifers, while temperate broad-leaved trees have only rarely been studied. We examined the magnitude and dynamics of the use of stem water reserves for transpiration in five coexisting temperate broad-leaved trees with largely different morphology and physiology (genera Fagus, Fraxinus, Tilia, Carpinus and Acer). We expected that differences in water storage patterns would mostly reflect species differences in wood anatomy (ring vs. diffuse-porous) and wood density. Sap flux density was recorded synchronously at five positions along the root-to-branch flow path of mature trees (roots, three stem positions and branches) with high temporal resolution (2 min) and related to stem radius changes recorded with electronic point dendrometers. The daily amount of stored stem water withdrawn for transpiration was estimated by comparing the integrated flow at stem base and stem top. The temporal coincidence of flows at different positions and apparent time lags were examined by cross-correlation analysis. Our results confirm that internal water stores play an important role in the four diffuse-porous species with estimated 5-12 kg day(-1) being withdrawn on average in 25-28 m tall trees representing 10-22% of daily transpiration; in contrast, only 0.5-2.0 kg day(-1) was withdrawn in ring-porous Fraxinus. Wood density had a large influence on storage; sapwood area (diffuse- vs. ring-porous) may be another influential factor but its effect was not significant. Across the five species, the length of the time lag in flow at stem top and stem base was positively related to the size of stem storage. The stem stores were mostly exhausted when the soil matrix potential dropped below -0.1 MPa and daily mean vapor pressure deficit exceeded 3-5 hPa. We conclude that stem storage is an important factor improving the water balance of diffuse-porous temperate broad-leaved trees in moist periods, while it may be of low relevance in dry periods and in ring-porous species.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Valetov, Eremey Vladimirovich
2017-01-01
While the first particle accelerators were electrostatic machines, and several electrostatic storage rings were subsequently commissioned and operated, electrostatic storage rings pose a number of challenges. Unlike motion in the magnetic field, where particle energy remains constant, particle energy generally changes in electrostatic elements. Conservation of energy in an electrostatic element is, in practice, only approximate, and it requires careful and accurate design, manufacturing, installation, and operational use. Electrostatic deflectors require relatively high electrostatic fields, tend to introduce nonlinear aberrations of all orders, and are more challenging to manufacture than homogeneous magnetic dipoles. Accordingly, magnetic storage rings are overwhelmingly prevalent.more » The search for electric dipole moments (EDMs) of fundamental particles is of key importance in the study of C and CP violations and their sources. C and CP violations are part of the Sakharov conditions that explain the matter–antimatter asymmetry in the universe. Determining the source of CP violations would provide valuable empirical insight for beyond-Standard-Model physics. EDMs of fundamental particles have not to this date been experimentally observed. The search for fundamental particle EDMs has narrowed the target search region; however, an EDM signal is yet to be discovered. In 2008, Brookhaven National Laboratory (BNL) had proposed the frozen spin (FS) concept for the search of a deuteron EDM. The FS concept envisions launching deuterons through a storage ring with combined electrostatic and magnetic fields. The electrostatic and magnetic fields are in a proportion that would, without an EDM, freeze the deuteron’s spin along its momentum as the deuteron moves around the lattice. The radial electrostatic field would result in a torque on the spin vector, proportional to a deuteron EDM, rotating the spin vector out of the midplane.« less
Bäckström, E; Hanstorp, D; Hole, O M; Kaminska, M; Nascimento, R F; Blom, M; Björkhage, M; Källberg, A; Löfgren, P; Reinhed, P; Rosén, S; Simonsson, A; Thomas, R D; Mannervik, S; Schmidt, H T; Cederquist, H
2015-04-10
We use a novel electrostatic ion storage ring to measure the radiative lifetime of the upper level in the 3p^{5} ^{2}P_{1/2}^{o}→3p^{5} ^{2}P_{3/2}^{o} spontaneous radiative decay in ^{32}S^{-} to be 503±54 sec. This is by orders of magnitude the longest lifetime ever measured in a negatively charged ion. Cryogenic cooling of the storage ring gives a residual-gas pressure of a few times 10^{-14} mbar at 13 K and storage of 10 keV sulfur anions for more than an hour. Our experimental results differ by 1.3σ from the only available theoretical prediction [P. Andersson et al., Phys. Rev. A 73, 032705 (2006)].
Zhou, Chen-hui; Wang, Chun-xi; Xie, Guang-bin; Wu, Ling-yun; Wei, Yong-xiang; Wang, Qiang; Zhang, Hua-sheng; Hang, Chun-hua; Zhou, Meng-liang; Shi, Ji-xin
2015-12-10
Early brain injury (EBI) determines the unfavorable outcomes after subarachnoid hemorrhage (SAH). Fisetin, a natural flavonoid, has anti-inflammatory and neuroprotection properties in several brain injury models, but the role of fisetin on EBI following SAH remains unknown. Our study aimed to explore the effects of fisetin on EBI after SAH in rats. Adult male Sprague-Dawley rats were randomly divided into the sham and SAH groups, fisetin (25mg/kg or 50mg/kg) or equal volume of vehicle was given at 30min after SAH. Neurological scores and brain edema were assayed. The protein expression of toll-like receptor 4 (TLR 4), p65, ZO-1 and bcl-2 was examined by Western blot. TLR 4 and p65 were also assessed by immunohistochemistry (IHC). Enzyme-linked immunosorbent assay (ELISA) was performed to detect the production of pro-inflammatory cytokines. Terminal deoxynucleotidyl transferase-mediated uridine 5'-triphosphate-biotin nick end-labeling (TUNEL) was perform to assess neural cell apoptosis. High-dose (50mg/kg) fisetin significantly improved neurological function and reduced brain edema at both 24h and 72h after SAH. Remarkable reductions of TLR 4 expression and nuclear factor κB (NF-κB) translocation to nucleus were detected after fisetin treatment. In addition, fisetin significantly reduced the productions of pro-inflammatory cytokines, decreased neural cell apoptosis and increased the protein expression of ZO-1 and bcl-2. Our data provides the evidence for the first time that fisetin plays a protective role in EBI following SAH possibly by suppressing TLR 4/NF-κB mediated inflammatory pathway. Copyright © 2015 Elsevier B.V. All rights reserved.
Bicen, A Ozan; West, Leanne L; Cesar, Liliana; Inan, Omer T
2018-01-01
Intravenous (IV) therapy is prevalent in hospital settings, where fluids are typically delivered with an IV into a peripheral vein of the patient. IV infiltration is the inadvertent delivery of fluids into the extravascular space rather than into the vein (and requires urgent treatment to avoid scarring and severe tissue damage), for which medical staff currently needs to check patients periodically. In this paper, the performance of two non-invasive sensing modalities, electrical bioimpedance (EBI), and skin strain sensing, for the automatic detection of IV infiltration was investigated in an animal model. Infiltrations were physically simulated on the hind limb of anesthetized pigs, where the sensors for EBI and skin strain sensing were co-located. The obtained data were used to examine the ability to distinguish between infusion into the vein and an infiltration event using bioresistance and bioreactance (derived from EBI), as well as skin strain. Skin strain and bioresistance sensing could achieve detection rates greater than 0.9 for infiltration fluid volumes of 2 and 10 mL, respectively, for a given false positive, i.e., false alarm rate of 0.05. Furthermore, the fusion of multiple sensing modalities could achieve a detection rate of 0.97 with a false alarm rate of 0.096 for 5mL fluid volume of infiltration. EBI and skin strain sensing can enable non-invasive and real-time IV infiltration detection systems. Fusion of multiple sensing modalities can help to detect expanded range of leaking fluid volumes. The provided performance results and comparisons in this paper are an important step towards clinical translation of sensing technologies for detecting IV infiltration.
Bicen, A. Ozan; West, Leanne L.; Cesar, Liliana
2018-01-01
Intravenous (IV) therapy is prevalent in hospital settings, where fluids are typically delivered with an IV into a peripheral vein of the patient. IV infiltration is the inadvertent delivery of fluids into the extravascular space rather than into the vein (and requires urgent treatment to avoid scarring and severe tissue damage), for which medical staff currently needs to check patients periodically. In this paper, the performance of two non-invasive sensing modalities, electrical bioimpedance (EBI), and skin strain sensing, for the automatic detection of IV infiltration was investigated in an animal model. Infiltrations were physically simulated on the hind limb of anesthetized pigs, where the sensors for EBI and skin strain sensing were co-located. The obtained data were used to examine the ability to distinguish between infusion into the vein and an infiltration event using bioresistance and bioreactance (derived from EBI), as well as skin strain. Skin strain and bioresistance sensing could achieve detection rates greater than 0.9 for infiltration fluid volumes of 2 and 10 mL, respectively, for a given false positive, i.e., false alarm rate of 0.05. Furthermore, the fusion of multiple sensing modalities could achieve a detection rate of 0.97 with a false alarm rate of 0.096 for 5mL fluid volume of infiltration. EBI and skin strain sensing can enable non-invasive and real-time IV infiltration detection systems. Fusion of multiple sensing modalities can help to detect expanded range of leaking fluid volumes. The provided performance results and comparisons in this paper are an important step towards clinical translation of sensing technologies for detecting IV infiltration. PMID:29692956
Deivanai, Subramanian; Bindusara, Amitraghata Santhanam; Prabhakaran, Guruswamy; Bhore, Subhash Janardhan
2014-07-01
Endophytic bacteria do have several potential applications in medicine and in other various sectors of biotechnology including agriculture. Bacterial endophytes need to be explored for their potential applications in agricultural biotechnology. One of the potential applications of bacterial endophytes in agricultural is to enhance the growth of the agricultural crops. Hence, this study was undertaken to explore the plant growth promoting potential application of bacterial endophytes. The objective of this study was to examine the effect of endophytic bacteria from mangrove tree (Rhizophora apiculata Blume) for their efficacy in promoting seedling growth in rice. Eight endophytic bacterial isolates (EBIs) isolated from twig and petiole tissues of the mangrove were identified based on their 16S ribosomal ribonucleic acid (rRNA) gene sequence homology. Separately, surface sterilized paddy seeds were treated with cell-free broth and cell suspension of the EBIs. Rice seedlings were analyzed by various bioassays and data was recorded. The gene sequences of the isolates were closely related to two genera namely, Bacillus and Pantoea. Inoculation of EBIs from R. apiculata with rice seeds resulted in accelerated root and shoot growth with significant increase in chlorophyll content. Among the isolates, Pantoea ananatis (1MSE1) and Bacillus amyloliquefaciens (3MPE1) had shown predominance of activity. Endophytic invasion was recognized by the non-host by rapid accumulation of reactive oxygen species (ROS) and was counteracted by the production of hydrogen peroxide (H2O2) and lipid peroxide. The results demonstrated that EBIs from mangrove tree can increase the fitness of the rice seedlings under controlled conditions. These research findings could be useful to enhance the seedling growth and could serve as foundation in further research on enhancing the growth of the rice crop using endophytic bacteria.
CsI-Silicon Particle detector for Heavy ions Orbiting in Storage rings (CsISiPHOS)
NASA Astrophysics Data System (ADS)
Najafi, M. A.; Dillmann, I.; Bosch, F.; Faestermann, T.; Gao, B.; Gernhäuser, R.; Kozhuharov, C.; Litvinov, S. A.; Litvinov, Yu. A.; Maier, L.; Nolden, F.; Popp, U.; Sanjari, M. S.; Spillmann, U.; Steck, M.; Stöhlker, T.; Weick, H.
2016-11-01
A heavy-ion detector was developed for decay studies in the Experimental Storage Ring (ESR) at the GSI Helmholtz Centre for Heavy Ion Research in Darmstadt, Germany. This detector serves as a prototype for the in-pocket particle detectors for future experiments with the Collector Ring (CR) at FAIR (Facility for Antiproton and Ion Research). The detector includes a stack of six silicon pad sensors, a double-sided silicon strip detector (DSSD), and a CsI(Tl) scintillation detector. It was used successfully in a recent experiment for the detection of the β+-decay of highly charged 142Pm60+ ions. Based on the ΔE / E technique for particle identification and an energy resolution of 0.9% for ΔE and 0.5% for E (Full Width at Half Maximum (FWHM)), the detector is well-suited to distinguish neighbouring isobars in the region of interest.
NASA Astrophysics Data System (ADS)
Hosaka, M.; Yamamoto, N.; Takashima, Y.; Szwaj, C.; Le Parquier, M.; Evain, C.; Bielawski, S.; Adachi, M.; Zen, H.; Tanikawa, T.; Kimura, S.; Katoh, M.; Shimada, M.; Takahashi, T.
2013-02-01
We study the efficiency limitation affecting laser-induced coherent synchrotron radiation (CSR) at high laser power. Experiments are made on the UVSOR-II storage ring in conditions of narrowband terahertz CSR emission. While, at moderate power, CSR power increases quadratically with laser power, a noticeable decrease in efficiency and eventually a decrease in CSR power is observed experimentally at high power. Details of the underlying process are analyzed numerically. As the saturation effect depends almost instantaneously on the laser intensity, the saturation occurs locally in longitudinal space. This has important consequences on the modulation pattern induced on the electron bunch.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stillwell, B.; Billett, B.; Brajuskovic, B.
2017-06-20
Recent work on the design of the storage ring vacuum system for the Advanced Photon Source Upgrade project (APS-U) includes: revising the vacuum system design to accommodate a new lattice with reverse bend magnets, modifying the designs of vacuum chambers in the FODO sections for more intense incident synchrotron radiation power, modifying the design of rf-shielding bellows liners for better performance and reliability, modifying photon absorber designs to make better use of available space, and integrated planning of components needed in the injection, extraction and rf cavity straight sections. An overview of progress in these areas is presented.
Ivanyushenkov, Y.; Harkay, K.; Abliz, M.; ...
2015-04-01
In this study, a decade-long effort at the Advanced Photon Source (APS) of Argonne National Laboratory (ANL) on development of superconducting undulators culminated in December 2012 with the installation of the first superconducting undulator “SCU0” into Sector 6 of the APS storage ring. The device was commissioned in January 2013 and has been in user operation since. This paper presents the magnetic and cryogenic design of the SCU0 together with the results of stand-alone cold tests. The initial commissioning and characterization of SCU0 as well as its operating experience in the APS storage ring are described.
DOE Office of Scientific and Technical Information (OSTI.GOV)
M. Ferro-Luzzi; M. Bouwhuis; E. Passchier
1996-09-23
We report an absolute measurement of the tensor analyzing powers T20 and T22 in elastic electron-deuteron scattering at a momentum transfer of 1.6 fm{sup -1}. The novel approach of this measurement is the use of a tensor polarized 2H target internal to an electron storage ring, with in situ measurement of the polarization of the target gas. Scattered electrons and recoil deuterons were detected in coincidence with two large acceptance nonmagnetic detectors. The techniques demonstrated have broad applicability to further measurements of spin-dependent electron scattering.
NASA Astrophysics Data System (ADS)
Zhang, Qing-Kun; Wang, Lin; Li, Wei-Min; Gao, Wei-Wei
2015-12-01
The upgrade project of the Hefei Light Source storage ring is under way. In this paper, the broadband impedances of resistive wall and coated ceramic vacuum chamber are calculated using the analytic formula, and the wake fields and impedances of other designed vacuum chambers are simulated by CST code, and then a broadband impedance model is obtained. Using the theoretical formula, longitudinal and transverse single bunch instabilities are discussed. With the carefully-designed vacuum chamber, we find that the thresholds of the beam instabilities are higher than the beam current goal. Supported by Natural Science Foundation of China (11175182, 11175180)
Transparent lattice characterization with gated turn-by-turn data of diagnostic bunch train
NASA Astrophysics Data System (ADS)
Li, Yongjun; Cheng, Weixing; Ha, Kiman; Rainer, Robert
2017-11-01
Methods of characterization of a storage ring's lattice have traditionally been intrusive to routine operations. More importantly, the lattice seen by particles can drift with the beam current due to collective effects. To circumvent this, we have developed a novel approach for dynamically characterizing a storage ring's lattice that is transparent to operations. Our approach adopts a dedicated filling pattern which has a short, separate diagnostic bunch train (DBT). Through the use of a bunch-by-bunch feedback system, the DBT can be selectively excited on demand. Gated functionality of a beam position monitor system is capable of collecting turn-by-turn data of the DBT, from which the lattice can then be characterized after excitation. As the DBT comprises only about one percent of the total operational bunches, the effects of its excitation are negligible to users. This approach allows us to localize the distributed quadrupolar wakefields generated in the storage ring vacuum chamber during beam accumulation. While effectively transparent to operations, our approach enables us to dynamically control the beta beat and phase beat, and unobtrusively optimize performance of the National Synchrotron Light Source-II accelerator during routine operations.
Upgrade of BPM Electronics for the SPring-8 Storage Ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sasaki, Shigeki; Fujita, Takahiro; Shoji, Masazumi
2006-11-20
SPring-8, a 3rd generation synchrotron light source, has operated since 1997. Improvement of BPM performance is required as a part of upgrading activities of the storage ring as a light source. We have developed new electronics circuits for signal processing of the storage ring BPM, with target performance of sub-{mu}m range resolution with sufficiently fast measurement speed and good long-term stability. A set of the new circuits consists of multiplexers, an RF amplifier, a mixer, an IF amplifier, and a local oscillator for analog signal processing. The IF amplifier outputs are sampled with 16-bit 2-MSPS ADC on ADC boards andmore » the data are sent to a DSP board. The sampled data are processed and converted to position information in the DSP. A multiplexing method was employed to have a better stability of the performance by cancellation of variation common to each channel. Evaluation of the performance by using a prototype shows that position resolution well into the sub-{mu}m range has been achieved with a bandwidth of 1 kHz, and long-term stability of within 1 {mu}m has also been achieved.« less
Transparent lattice characterization with gated turn-by-turn data of diagnostic bunch train
Li, Yongjun; Cheng, Weixing; Ha, Kiman; ...
2017-11-21
Methods of characterization of a storage ring's lattice have traditionally been intrusive to routine operations. More importantly, the lattice seen by particles can drift with the beam current due to collective effects. To circumvent this, we have developed a novel approach for dynamically characterizing a storage ring's lattice that is transparent to operations. Our approach adopts a dedicated filling pattern which has a short, separate Diagnostic Bunch-Train (DBT). Through the use of a bunch-by-bunch feedback system, the DBT can be selectively excited on-demand. Gated functionality of a beam position monitor system is capable of collecting turn-by-turn data of the DBT,more » from which the lattice can then be characterized after excitation. As the DBT comprises only about one percent of the total operational bunches, the effects of its excitation are negligible to users. Therefore, this approach allows us to localize the distributed quadrupolar wake fields generated in the storage ring vacuum chamber during beam accumulation. While effectively transparent to operations, our approach enables us to dynamically control the beta-beat and phase-beat, and unobtrusively optimize performance of National Synchrotron Light Source-II accelerator during routine operations.« less
Synchrotron oscillation effects on an rf-solenoid spin resonance
NASA Astrophysics Data System (ADS)
Benati, P.; Chiladze, D.; Dietrich, J.; Gaisser, M.; Gebel, R.; Guidoboni, G.; Hejny, V.; Kacharava, A.; Kamerdzhiev, V.; Kulessa, P.; Lehrach, A.; Lenisa, P.; Lorentz, B.; Maier, R.; Mchedlishvili, D.; Morse, W. M.; Öllers, D.; Pesce, A.; Polyanskiy, A.; Prasuhn, D.; Rathmann, F.; Semertzidis, Y. K.; Stephenson, E. J.; Stockhorst, H.; Ströher, H.; Talman, R.; Valdau, Yu.; Weidemann, Ch.; Wüstner, P.
2012-12-01
New measurements are reported for the time dependence of the vertical polarization of a 0.97GeV/c deuteron beam circulating in a storage ring and perturbed by an rf solenoid. The storage ring is the cooler synchrotron (COSY) located at the Forschungszentrum Jülich. The beam polarization was measured continuously using a 1.5 cm thick carbon target located at the edge of the circulating deuteron beam and the scintillators of the EDDA detector. An rf solenoid mounted on the ring was used to generate fields at and near the frequency of the 1-Gγ spin resonance. Measurements were made of the vertical beam polarization as a function of time with the operation of the rf solenoid in either fixed or continuously variable frequency mode. Using rf-solenoid strengths as large as 2.66×10-5revolutions/turn, slow oscillations (˜1Hz) were observed in the vertical beam polarization. When the circulating beam was continuously electron cooled, these oscillations completely reversed the polarization and showed no sign of diminishing in amplitude. But for the uncooled beam, the oscillation amplitude was damped to nearly zero within a few seconds. A simple spin-tracking model without the details of the COSY ring lattice was successful in reproducing these oscillations and demonstrating the sensitivity of the damping to the magnitude of the synchrotron motion of the beam particles. The model demonstrates that the characteristic features of measurements made in the presence of large synchrotron oscillations are distinct from the features of such measurements when made off resonance. These data were collected in preparation for a study of the spin coherence time, a beam property that needs to become long to enable a search for an electric dipole moment using a storage ring.
In-space inertial energy storage design
NASA Technical Reports Server (NTRS)
Studer, P. A.; Evans, H. E.
1981-01-01
Flywheel energy storage is a means of significantly improving the performance of space power systems. Two study contracts have been completed to investigate the merits of a magnetically suspended, ironless armature, ring rotor 'Mechanical Capacitor' design. The design of a suitable energy storage system is evaluated, taking into account baseline requirements, the motor generator, details regarding the suspension design, power conditioning, the rotor, and an example design. It appears on the basis of this evaluation that the inertial (flywheel) energy storage design is feasible.
Distributed trace using central performance counter memory
Satterfield, David L; Sexton, James C
2013-10-22
A plurality of processing cores, are central storage unit having at least memory connected in a daisy chain manner, forming a daisy chain ring layout on an integrated chip. At least one of the plurality of processing cores places trace data on the daisy chain connection for transmitting the trace data to the central storage unit, and the central storage unit detects the trace data and stores the trace data in the memory co-located in with the central storage unit.
Distributed trace using central performance counter memory
Satterfield, David L.; Sexton, James C.
2013-01-22
A plurality of processing cores, are central storage unit having at least memory connected in a daisy chain manner, forming a daisy chain ring layout on an integrated chip. At least one of the plurality of processing cores places trace data on the daisy chain connection for transmitting the trace data to the central storage unit, and the central storage unit detects the trace data and stores the trace data in the memory co-located in with the central storage unit.
Kneipp, Shawn M.; Leeman, Jennifer; McCall, Pamela; Hassmiller-Lich, Kristen; Bobashev, Georgiy; Schwartz, Todd A.; Gilmore, Robert; Riggan, Scott
2016-01-01
The adoption and implementation of evidence-based interventions (EBIs) are end goals of translational research, however, potential end-users’ perceptions of an EBI’s value have contributed to low rates of adoption. In this article, we describe our application of emerging dissemination and implementation science theoretical perspectives, community engagement, and systems science principles to develop a novel EBI dissemination approach. Using consumer-driven, graphics-rich simulation, the approach demonstrates predicted implementation effects on health and employment outcomes for socioeconomically disadvantaged women at the local level, and is designed to increase adoption interest of county program managers accountable for improving these outcomes in their communities. PMID:26244479
De Sousa, Paul A; Steeg, Rachel; Wachter, Elisabeth; Bruce, Kevin; King, Jason; Hoeve, Marieke; Khadun, Shalinee; McConnachie, George; Holder, Julie; Kurtz, Andreas; Seltmann, Stefanie; Dewender, Johannes; Reimann, Sascha; Stacey, Glyn; O'Shea, Orla; Chapman, Charlotte; Healy, Lyn; Zimmermann, Heiko; Bolton, Bryan; Rawat, Trisha; Atkin, Isobel; Veiga, Anna; Kuebler, Bernd; Serano, Blanca Miranda; Saric, Tomo; Hescheler, Jürgen; Brüstle, Oliver; Peitz, Michael; Thiele, Cornelia; Geijsen, Niels; Holst, Bjørn; Clausen, Christian; Lako, Majlinda; Armstrong, Lyle; Gupta, Shailesh K; Kvist, Alexander J; Hicks, Ryan; Jonebring, Anna; Brolén, Gabriella; Ebneth, Andreas; Cabrera-Socorro, Alfredo; Foerch, Patrik; Geraerts, Martine; Stummann, Tina C; Harmon, Shawn; George, Carol; Streeter, Ian; Clarke, Laura; Parkinson, Helen; Harrison, Peter W; Faulconbridge, Adam; Cherubin, Luca; Burdett, Tony; Trigueros, Cesar; Patel, Minal J; Lucas, Christa; Hardy, Barry; Predan, Rok; Dokler, Joh; Brajnik, Maja; Keminer, Oliver; Pless, Ole; Gribbon, Philip; Claussen, Carsten; Ringwald, Annette; Kreisel, Beate; Courtney, Aidan; Allsopp, Timothy E
2017-04-01
A fast track "Hot Start" process was implemented to launch the European Bank for Induced Pluripotent Stem Cells (EBiSC) to provide early release of a range of established control and disease linked human induced pluripotent stem cell (hiPSC) lines. Established practice amongst consortium members was surveyed to arrive at harmonised and publically accessible Standard Operations Procedures (SOPs) for tissue procurement, bio-sample tracking, iPSC expansion, cryopreservation, qualification and distribution to the research community. These were implemented to create a quality managed foundational collection of lines and associated data made available for distribution. Here we report on the successful outcome of this experience and work flow for banking and facilitating access to an otherwise disparate European resource, with lessons to benefit the international research community. ETOC: The report focuses on the EBiSC experience of rapidly establishing an operational capacity to procure, bank and distribute a foundational collection of established hiPSC lines. It validates the feasibility and defines the challenges of harnessing and integrating the capability and productivity of centres across Europe using commonly available resources currently in the field. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
The ATLAS multi-user upgrade and potential applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mustapha, B.; Nolen, J. A.; Savard, G.
With the recent integration of the CARIBU-EBIS charge breeder into the ATLAS accelerator system to provide for more pure and efficient charge breeding of radioactive beams, a multi-user upgrade of the ATLAS facility is being proposed to serve multiple users simultaneously. ATLAS was the first superconducting ion linac in the world and is the US DOE low-energy Nuclear Physics National User Facility. The proposed upgrade will take advantage of the continuous-wave nature of ATLAS and the pulsed nature of the EBIS charge breeder in order to simultaneously accelerate two beams with very close mass-to-charge ratios; one stable from the existingmore » ECR ion source and one radioactive from the newly commissioned EBIS charge breeder. In addition to enhancing the nuclear physics program, beam extraction at different points along the linac will open up the opportunity for other potential applications; for instance, material irradiation studies at ~ 1 MeV/u and isotope production at ~ 6 MeV/u or at the full ATLAS energy of ~ 15 MeV/u. The concept and proposed implementation of the ATLAS multi-user upgrade will be presented. Future plans to enhance the flexibility of this upgrade will also be presented.« less
Adapting an Evidence-Based Intervention Targeting HIV-Infected Prisoners in Malaysia
Copenhaver, Michael M.; Tunku, Noor; Ezeabogu, Ifeoma; Potrepka, Jessica; Zahari, Muhammad Muhsin A.; Kamarulzaman, Adeeba; Altice, Frederick L.
2011-01-01
HIV-infected prisoners in Malaysia represent a critical target population for secondary HIV risk reduction interventions and care. We report on the process and outcome of our formative research aimed at systematically selecting and adapting an EBI designed to reduce secondary HIV risk and improve adherence to antiretroviral therapy among soon-to-be-released HIV-infected prisoners. Our formative work involved a critical examination of established EBIs and associated published reports complemented by data elicited through structured interviews and focus groups with key stakeholders, members of the target population, and their family members. Based on all information, we adapted the Holistic Health Recovery Program targeting people living with HIV (HHRP+), an EBI, to consist of eight 2-hour sessions that cover a range of specified topics so that participants may individually apply intervention content as needed to accommodate their particular substance abuse, HIV risk, and antiretroviral adherence issues. This study provides a complete example of the process of selecting and adapting an EBI—taking into account both empirical evidence and input from target organization stakeholders and target population members and their families—for use in real world prison settings where high-risk populations are concentrated. PMID:21860786
The ATLAS multi-user upgrade and potential applications
NASA Astrophysics Data System (ADS)
Mustapha, B.; Nolen, J. A.; Savard, G.; Ostroumov, P. N.
2017-12-01
With the recent integration of the CARIBU-EBIS charge breeder into the ATLAS accelerator system to provide for more pure and efficient charge breeding of radioactive beams, a multi-user upgrade of the ATLAS facility is being proposed to serve multiple users simultaneously. ATLAS was the first superconducting ion linac in the world and is the US DOE low-energy Nuclear Physics National User Facility. The proposed upgrade will take advantage of the continuous-wave nature of ATLAS and the pulsed nature of the EBIS charge breeder in order to simultaneously accelerate two beams with very close mass-to-charge ratios; one stable from the existing ECR ion source and one radioactive from the newly commissioned EBIS charge breeder. In addition to enhancing the nuclear physics program, beam extraction at different points along the linac will open up the opportunity for other potential applications; for instance, material irradiation studies at ~1 MeV/u, isotope production and radiobiological studies at ~6 MeV/u and at the full ATLAS energy of ~15 MeV/u. The concept and proposed implementation of the ATLAS multi-user upgrade will be discussed. Future plans to enhance the flexibility of this upgrade will be presented.
15. DETAILED VIEW OF ENRICHED URANIUM STORAGE TANK. THE ADDITION ...
15. DETAILED VIEW OF ENRICHED URANIUM STORAGE TANK. THE ADDITION OF THE GLASS RINGS SHOWN AT THE TOP OF THE TANK HELPS PREVENT THE URANIUM FROM REACHING CRITICALITY LIMITS. (4/12/62) - Rocky Flats Plant, General Manufacturing, Support, Records-Central Computing, Southern portion of Plant, Golden, Jefferson County, CO
A permanent-magnet rotor for a high-temperature superconducting bearing
NASA Astrophysics Data System (ADS)
Mulcahy, T. M.; Hull, J. R.; Uherka, K. L.; Abboud, R. G.; Wise, J. H.; Carnegie, D. W.
1995-06-01
Design, fabrication, and performance, of a 1/3-m dia., 10-kg flywheel rotor with only one bearing is discussed. To achieve low-loss energy storage, the rotor's segmented-ring permanent-magnet (PM) is optimized for levitation and circumferential homogeneity. The magnet's carbon composite bands enable practical energy storage.
NASA Technical Reports Server (NTRS)
Studer, P. A.; Evans, H. E. (Inventor)
1978-01-01
A high efficiency, flywheel type energy storage device which comprises an electronically commutated d.c. motor/generator unit having a massive flywheel rotor magnetically suspended around a ring shaped stator is presented. During periods of low energy demand, the storage devices were operated as a motor, and the flywheel motor was brought up to operating speed. Energy was drawn from the device functioning as a generator as the flywheel rotor rotated during high energy demand periods.
Overview of a flywheel stack energy storage system
NASA Technical Reports Server (NTRS)
Kirk, James A.; Anand, Davinder K.
1988-01-01
The concept of storing electrical energy in rotating flywheels provides an attractive substitute to batteries. To realize these advantages the critical technologies of rotor design, composite materials, magnetic suspension, and high efficiency motor/generators are reviewed in this paper. The magnetically suspended flywheel energy storage system, currently under development at the University of Maryland, consisting of a family of interference assembled rings, is presented as an integrated solution for energy storage.
Space-charge-sustained microbunch structure in the Los Alamos Proton Storage Ring
NASA Astrophysics Data System (ADS)
Cousineau, S.; Danilov, V.; Holmes, J.; Macek, R.
2004-09-01
We present experimental data from the Los Alamos Proton Storage Ring (PSR) showing long-lived linac microbunch structure during beam storage with no rf bunching. Analysis of the experimental data and particle-in-cell simulations of the experiments indicate that space charge, coupled with energy spread effects, is responsible for the sustained microbunch structure. The simulated longitudinal phase space of the beam reveals a well-defined separatrix in the phase space between linac microbunches, with particles executing unbounded motion outside of the separatrix. We show that the longitudinal phase space of the beam was near steady state during the PSR experiments, such that the separatrix persisted for long periods of time. Our simulations indicate that the steady state is very sensitive to the experimental conditions. Finally, we solve the steady-state problem in an analytic, self-consistent fashion for a set of periodic longitudinal space-charge potentials.
Computational Analysis on Performance of Thermal Energy Storage (TES) Diffuser
NASA Astrophysics Data System (ADS)
Adib, M. A. H. M.; Adnan, F.; Ismail, A. R.; Kardigama, K.; Salaam, H. A.; Ahmad, Z.; Johari, N. H.; Anuar, Z.; Azmi, N. S. N.
2012-09-01
Application of thermal energy storage (TES) system reduces cost and energy consumption. The performance of the overall operation is affected by diffuser design. In this study, computational analysis is used to determine the thermocline thickness. Three dimensional simulations with different tank height-to-diameter ratio (HD), diffuser opening and the effect of difference number of diffuser holes are investigated. Medium HD tanks simulations with double ring octagonal diffuser show good thermocline behavior and clear distinction between warm and cold water. The result show, the best performance of thermocline thickness during 50% time charging occur in medium tank with height-to-diameter ratio of 4.0 and double ring octagonal diffuser with 48 holes (9mm opening ~ 60%) acceptable compared to diffuser with 6mm ~ 40% and 12mm ~ 80% opening. The conclusion is computational analysis method are very useful in the study on performance of thermal energy storage (TES).
Astrochemistry in TSR and CSR Ion Storage Rings
NASA Astrophysics Data System (ADS)
Novotny, Oldrich
2017-04-01
Dissociative recombination (DR) of molecular ions plays a key role in controlling the charge density and composition of the cold interstellar medium (ISM). Experimental data on DR are required in order to understand the chemical network in the ISM and related processes such as star formation from molecular clouds. Needed data include not only total reaction cross sections, but also the chemical composition and excitation states of the neutral products. Utilizing the TSR storage ring in Heidelberg, Germany, we have carried out DR measurements for astrophysically important molecular ions. We use a merged electron-ion beams technique combined with event-by-event fragment counting and fragment imaging. The count rate of detected neutral DR products yields the absolute DR rate coefficient. Imaging the distribution of fragment distances provides information on the kinetic energy released including the states of both the initial molecule and the final products. Additional kinetic energy sensitivity of the employed detector allows for identification of fragmentation channels by fragment-mass combination within each dissociation event. Such combined information is essential for studies on DR of polyatomic ions with multi-channel breakup. The recently commissioned Cryogenic Storage Ring (CSR) in Heidelberg, Germany, extends the experimental capabilities of TSR by operation at cryogenic temperatures down to 6 K. At these conditions residual gas densities down to 100 cm-3 can be reached resulting in beam storage times of several hours. Long storage in the cold environment allows the ions to relax down to their rotational ground state, thus mimicking well the conditions in the cold ISM. A variety of astrophysically relevant reactions will be investigated at these conditions, such as DR, electron impact excitation, ion-neutral collisions, etc. We report our TSR results on DR of HCl+ and D2Cl+. We also present first results from the CSR commissioning experiments.
NASA Astrophysics Data System (ADS)
Plum, M.
The beam instability at the Los Alamos Proton Storage Ring (PSR) most likely involves coupled oscillations between electrons and protons. For this instability to occur, there must be a strong source of electrons. Investigation of the various sources of electrons in the PSR had begun. Copious electron production is expected in the injection section because this section contains the stripper foil. This foil is mounted near the center of the beam pipe, and both circulating and injected protons pass through it, thus allowing ample opportunity for electron production. This paper discusses various mechanisms for electron production, beam-induced electric fields, and electron motion in the vicinity of the foil.
Lifetimes of relativistic heavy-ion beams in the High Energy Storage Ring of FAIR
NASA Astrophysics Data System (ADS)
Shevelko, V. P.; Litvinov, Yu. A.; Stöhlker, Th.; Tolstikhina, I. Yu.
2018-04-01
The High Energy Storage Ring, HESR, will be constructed at the Facility for Antiproton and Ion Research, FAIR, Darmstadt. For the first time, it will be possible to perform experiments with cooled high-intensity stable and radioactive heavy ions at highly relativistic energies. To design experiments at the HESR, realistic estimations of beam lifetimes are indispensable. Here we report calculated cross sections and lifetimes for typical U88+ , U90+ , U92+ , Sn49+ and Sn50+ ions in the energy range E = 400 MeV/u-5 GeV/u, relevant for the HESR. Interactions with the residual gas and with internal gas-jet targets are also considered.
Benchmarking of Touschek Beam Lifetime Calculations for the Advanced Photon Source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiao, A.; Yang, B.
2017-06-25
Particle loss from Touschek scattering is one of the most significant issues faced by present and future synchrotron light source storage rings. For example, the predicted, Touschek-dominated beam lifetime for the Advanced Photon Source (APS) Upgrade lattice in 48-bunch, 200-mA timing mode is only ~ 2 h. In order to understand the reliability of the predicted lifetime, a series of measurements with various beam parameters was performed on the present APS storage ring. This paper first describes the entire process of beam lifetime measurement, then compares measured lifetime with the calculated one by applying the measured beam parameters. The resultsmore » show very good agreement.« less
Emittance measurements in low energy ion storage rings
NASA Astrophysics Data System (ADS)
Hunt, J. R.; Carli, C.; Resta-López, J.; Welsch, C. P.
2018-07-01
The development of the next generation of ultra-low energy antiproton and ion facilities requires precise information about the beam emittance to guarantee optimum performance. In the Extra-Low ENergy Antiproton storage ring (ELENA) the transverse emittances will be measured by scraping. However, this diagnostic measurement faces several challenges: non-zero dispersion, non-Gaussian beam distributions due to effects of the electron cooler and various systematic errors such as closed orbit offsets and inaccurate rms momentum spread estimation. In addition, diffusion processes, such as intra-beam scattering might lead to emittance overestimates. Here, we present algorithms to efficiently address the emittance reconstruction in presence of the above effects, and present simulation results for the case of ELENA.
NASA Astrophysics Data System (ADS)
Ivanyushenkov, Y.; Harkay, K.; Borland, M.; Dejus, R.; Dooling, J.; Doose, C.; Emery, L.; Fuerst, J.; Gagliano, J.; Hasse, Q.; Kasa, M.; Kenesei, P.; Sajaev, V.; Schroeder, K.; Sereno, N.; Shastri, S.; Shiroyanagi, Y.; Skiadopoulos, D.; Smith, M.; Sun, X.; Trakhtenberg, E.; Xiao, A.; Zholents, A.; Gluskin, E.
2017-10-01
Development of superconducting undulators continues at the Advanced Photon Source (APS). Two years after successful installation and commissioning of the first relatively short superconducting undulator "SCU0" in Sector 6 of the APS storage ring, the second 1.1-m-long superconducting undulator "SCU1" was installed in Sector 1 of the APS. The device has been in user operation since its commissioning in May 2015. This paper describes the magnetic and cryogenic design of the SCU1 together with the results of stand-alone cold tests. The SCU1's magnetic and cryogenic performance as well as its operating experience in the APS storage ring are also presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le Pimpec, F.; /PSI, Villigen; Kirby, R.E.
In many accelerator storage rings running positively charged beams, ionization of residual gas and secondary electron emission (SEE) in the beam pipe will give rise to an electron cloud which can cause beam blow-up or loss of the circulating beam. A preventative measure that suppresses electron cloud formation is to ensure that the vacuum wall has a low secondary emission yield (SEY). The SEY of thin films of TiN, sputter deposited Non-Evaporable Getters and a novel TiCN alloy were measured under a variety of conditions, including the effect of re-contamination from residual gas.
NASA Astrophysics Data System (ADS)
Baglin, C.; Baird, S.; Bassompierre, G.; Borreani, G.; Brient, J.-C.; Broll, C.; Brom, J.-M.; Bugge, L.; Buran, T.; Burq, J.-P.; Bussière, A.; Buzzo, A.; Cester, R.; Chemarin, M.; Chevallier, M.; Escoubes, B.; Fay, J.; Ferroni, S.; Gracco, V.; Guillaud, J.-P.; Khan-Aronsen, E.; Kirsebom, K.; Kylling, A.; Ille, B.; Lambert, M.; Leistam, L.; Lundby, A.; Macri, M.; Marchetto, F.; Menichetti, E.; Mörch, Ch.; Mouellic, B.; Olsen, D.; Pastrone, N.; Petrillo, L.; Pia, M. G.; Poole, J.; Poulet, M.; Rinaudo, G.; Santroni, A.; Severi, M.; Skjevling, G.; Stapnes, S.; Stugu, B.; R704 Collaboration
1986-04-01
This experiment has been performed at the CERN Intersecting Storage Rings to study the direct formation of charmonium states in antiproton-proton annihilations. The experimental program has partly been devoted to an inclusive scan for overlinepp → J/ψ + X in the range 3520-3530 MeV/ c2. A cluster of five events has been observed in a narrow energy band, centred on the centre of gravity of the 3P J states where the 1P 1 is expected to be. When interpreted as a new resonace, these data yield a mass m = 3525.4±0.8 MeV/ c2.
Modification of a liquid hydrogen tank for integrated refrigeration and storage
NASA Astrophysics Data System (ADS)
Swanger, A. M.; Jumper, K. M.; Fesmire, J. E.; Notardonato, W. U.
2015-12-01
The modification and outfitting of a 125,000-liter liquid hydrogen tank was performed to provide integrated refrigeration and storage capability. These functions include zero boil-off, liquefaction, and densification and therefore require provisions for sub-atmospheric tank pressures within the vacuum-jacketed, multilayer insulated tank. The primary structural modification was to add stiffening rings inside the inner vessel. The internal stiffening rings were designed, built, and installed per the ASME Boiler and Pressure Vessel Code, Section VIII, to prevent collapse in the case of vacuum jacket failure in combination with sub-atmospheric pressure within the tank. For the integrated refrigeration loop, a modular, skeleton-type heat exchanger, with refrigerant temperature instrumentation, was constructed using the stiffening rings as supports. To support the system thermal performance testing, three custom temperature rakes were designed and installed along the 21-meter length of the tank, once again using rings as supports. The temperature rakes included a total of 20 silicon diode temperature sensors mounted both vertically and radially to map the bulk liquid temperature within the tank. The tank modifications were successful and the system is now operational for the research and development of integrated refrigeration technology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Somerville, Chris
Berkeley Lab's Chris Somerville is a leading authority on the structure and function of plant cell walls, which comprise most of the body mass of higher plants. He views the knowledge of cell wall structure and function as furthering the development of plants with improved usefulness: these plants are strong potential sources of renewable materials and biofuel feedstocks. His scientific expertise defines an ideal match of his interest - in the development of cellulosic and other solar-to-fuel science - with his recent appointment as Director of the Energy Biosciences Institute (EBI). With colleagues in biology, physical sciences, engineering, and environmentalmore » and the social sciences, he now leads the EBI multidisciplinary teams' research efforts to develop next-generation, carbon-neutral transportation fuels.« less
Patel, Rajesh; Mevada, Vishal; Prajapati, Dhaval; Dudhagara, Pravin; Koringa, Prakash; Joshi, C G
2015-03-01
We report Metagenome from the saline desert soil sample of Little Rann of Kutch, Gujarat State, India. Metagenome consisted of 633,760 sequences with size 141,307,202 bp and 56% G + C content. Metagenome sequence data are available at EBI under EBI Metagenomics database with accession no. ERP005612. Community metagenomics revealed total 1802 species belonged to 43 different phyla with dominating Marinobacter (48.7%) and Halobacterium (4.6%) genus in bacterial and archaeal domain respectively. Remarkably, 18.2% sequences in a poorly characterized group and 4% gene for various stress responses along with versatile presence of commercial enzyme were evident in a functional metagenome analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burkel, L.; Dejus, R.; Maines, J.
This report is a description of the current status of the magnetic measurement facility and is a basic instructional manual for the operation of the facility and its components. Please refer to the appendices for more detailed information about specific components and procedures. The purpose of the magnetic measurement facility is to take accurate measurements of the magnetic field in the gay of the IDs in order to determine the effect of the ID on the stored particle beam and the emitted radiation. The facility will also play an important role when evaluating new ideas, novel devices, and inhouse prototypesmore » as part of the ongoing research and development program at the APS. The measurements will be performed with both moving search coils and moving Hall probes. The IDs will be evaluated by computer modeling of the emitted radiation for any given (measured) magnetic field map. The quality of the magnetic field will be described in terms of integrated multipoles for the effect on Storage Ring performance and in terms of the derived trajectories for the emitted radiation. Before being installed on the Storage Ring, every device will be measured and characterized to assure that it is compatible with Storage Ring requirements and radiation specifications. The accuracy that the APS needs to achieve for magnetic measurements will be based on these specifications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huamg, C. W., E-mail: huang.zw@nsrrc.org.tw; Hwang, C. S., E-mail: cshwang@nsrrc.org.tw; Department of Electrophysics, National Chiao Tung University, Hsinchu 300, Taiwan
The Taiwan Photon Source (TPS) has been successfully commissioned. However, the minimum emittance in the TPS lattice is 1.6 nm rad. In the existing TPS storage ring lattice, it is imperative to reduce the emittance to below 1 nm rad. Therefore, a feasibility study for reducing the effective emittance of the TPS storage ring by using a Robinson wiggler was launched; the reduction is necessary to enhance the photon brilliance. In this study, a permanent-magnet multiperiod Robinson wiggler (MRW) was developed for use instead of the single-period Robinson wiggler. In general, the quadruple field of a combined function magnet inmore » the storage ring is approximately few tesla per meter. According to beam dynamic analysis, we found that it is necessary to adopt a high gradient (40 T/m) combined-function MRW magnet to reduce the emittance effectively. Therefore, a high gradient field strength is required in the combined function MRW magnet. In this study, the quadrupole field strength of the MRW magnet was allowed to be approximately 40 T/m at a magnet gap of 20 mm. The period length of the MRW magnet was 300 mm and the period number was 16. The of MRWs is discussed in regard to the possibility of increasing the photon brilliance from IU22.« less
Electron cooling of a bunched ion beam in a storage ring
NASA Astrophysics Data System (ADS)
Zhao, He; Mao, Lijun; Yang, Jiancheng; Xia, Jiawen; Yang, Xiaodong; Li, Jie; Tang, Meitang; Shen, Guodong; Ma, Xiaoming; Wu, Bo; Wang, Geng; Ruan, Shuang; Wang, Kedong; Dong, Ziqiang
2018-02-01
A combination of electron cooling and rf system is an effective method to compress the beam bunch length in storage rings. A simulation code based on multiparticle tracking was developed to calculate the bunched ion beam cooling process, in which the electron cooling, intrabeam scattering (IBS), ion beam space-charge field, transverse and synchrotron motion are considered. Meanwhile, bunched ion beam cooling experiments have been carried out in the main cooling storage ring (CSRm) of the Heavy Ion Research Facility in Lanzhou, to investigate the minimum bunch length obtained by the cooling method, and study the dependence of the minimum bunch length on beam and machine parameters. The experiments show comparable results to those from simulation. Based on these simulations and experiments, we established an analytical model to describe the limitation of the bunch length of the cooled ion beam. It is observed that the IBS effect is dominant for low intensity beams, and the space-charge effect is much more important for high intensity beams. Moreover, the particles will not be bunched for much higher intensity beam. The experimental results in CSRm show a good agreement with the analytical model in the IBS dominated regime. The simulation work offers us comparable results to those from the analytical model both in IBS dominated and space-charge dominated regimes.
The Synthesis of Cellulose Graft Copolymers Using Cu(0)-Mediated Polymerization
NASA Astrophysics Data System (ADS)
Donaldson, Jason L.
Cellulose is the most abundant renewable polymer on the planet and there is great interest in expanding its use beyond its traditional applications. However, its hydrophilicity and insolubility in most common solvent systems are obstacles to its widespread use in advanced materials. One way to counteract this is to attach hydrophobic polymer chains to cellulose: this allows the properties of the copolymer to be tailored by the molecular weight, density, and physical properties of the grafts. Two methods were used here to synthesize the graft copolymers: a 'grafting-from' approach, where synthetic chains were grown outward from bromoester moieties on cellulose (Cell-BiB) via Cu(0)-mediated polymerization; and a 'grafting-to' approach, where fully formed synthetic chains with terminal sulfide functionality were added to cellulose acetate with methacrylate functionality (CA-MAA) via thiol-ene Michael addition. The Cell-BiB was synthesized in the ionic liquid 1-butyl-3-methylimidazolium chloride and had a degree of substitution of 1.13. Polymerization from Cell-BiB proceeded at similar but slightly slower rate than an analogous non-polymeric initiator (EBiB). The average graft density of poly(methyl acrylate) chains was 0.71 chains/ring, with a maximum of 1.0 obtained. The graft density when grafting poly(methyl methacrylate) was only 0.15, and this appeared to be due to the slow initiation of BiB groups. Using EBiB to model the reaction and improve the design should allow this to be overcome. Chain extension experiments demonstrated the living behaviour of the polymer. The CA-MAA was synthesized by esterification with methacrylic acid. Reactions of CA-MAA with thiophenol and dodecanethiol resulted in quantitative addition of the thiol to the alkene. The grafts were synthesized by Cu(0)-mediated polymerization from a bifunctional initiator containing a disulfide bond, followed by reduction to sulfides. The synthetic polymers were successfully grafted to CA-MAA but the grafting yield was limited by the low sulfide functionality. Better retention of sulfide functionality is necessary for more efficient grafting.
Structure-based classification and ontology in chemistry
2012-01-01
Background Recent years have seen an explosion in the availability of data in the chemistry domain. With this information explosion, however, retrieving relevant results from the available information, and organising those results, become even harder problems. Computational processing is essential to filter and organise the available resources so as to better facilitate the work of scientists. Ontologies encode expert domain knowledge in a hierarchically organised machine-processable format. One such ontology for the chemical domain is ChEBI. ChEBI provides a classification of chemicals based on their structural features and a role or activity-based classification. An example of a structure-based class is 'pentacyclic compound' (compounds containing five-ring structures), while an example of a role-based class is 'analgesic', since many different chemicals can act as analgesics without sharing structural features. Structure-based classification in chemistry exploits elegant regularities and symmetries in the underlying chemical domain. As yet, there has been neither a systematic analysis of the types of structural classification in use in chemistry nor a comparison to the capabilities of available technologies. Results We analyze the different categories of structural classes in chemistry, presenting a list of patterns for features found in class definitions. We compare these patterns of class definition to tools which allow for automation of hierarchy construction within cheminformatics and within logic-based ontology technology, going into detail in the latter case with respect to the expressive capabilities of the Web Ontology Language and recent extensions for modelling structured objects. Finally we discuss the relationships and interactions between cheminformatics approaches and logic-based approaches. Conclusion Systems that perform intelligent reasoning tasks on chemistry data require a diverse set of underlying computational utilities including algorithmic, statistical and logic-based tools. For the task of automatic structure-based classification of chemical entities, essential to managing the vast swathes of chemical data being brought online, systems which are capable of hybrid reasoning combining several different approaches are crucial. We provide a thorough review of the available tools and methodologies, and identify areas of open research. PMID:22480202
Fermilab Tevatron and Pbar source status report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edwards, H.
1986-08-01
The antiproton production cycle is enumerated, and the commissioning of the antiproton source is described, giving milestones and major obstacles. The Tevatron collider operation is described, including procedure to load the Tevatron with three bunches of protons and three bunches of antiprotons. Commissioning of the Main Ring and Tevatron for collider operation is described. Development and accelerator studies in four areas were necessary: main ring RF manipulations; controls and applications software support; Tevatron storage and low-beta squeeze sequence; and study of various beam transfers, storage steps, and sequences. Final tests are described. A long range upgrade program is presently undermore » evaluation to accomplish these goals: luminosity increase to 5 x 10/sup 31/ cm/sup -2/sec/sup -1/, production rates up to 4 x 10/sup 11/ antiprotons/hr, and intensity increase for fixed target operation. Beam quality is to be improved by the injector and main ring upgrades, and the luminosity goal is addressed by the Collider upgrade. (LEW)« less
Kicker field simulation and measurement for the muon g-2 experiment at FNAL
NASA Astrophysics Data System (ADS)
Chang, Seung Pyo; Kim, Young Im; Choi, Jihoon; Semertzidis, Yannis; muon g-2 experiment Collaboration
2017-01-01
In the Muon g-2 experiment, muon beam is injected to the storage ring in a slightly tilted orbit whose center is 77 mm away from the center of the ring. The kicker is needed to send the muon beam to the central orbit. The magnetic kicker is designed for the experiment and about 0.1 Tm field integral is needed. The peak current pulse is 4200 A to make this field integral. This strong kicker pulse could make unwanted eddy current occur. This eddy current could spoil the main magnetic field of the storage ring. This could be a critical threat to the precision of experiment. The kicker field simulation has done using OPERA to estimate the effects. Also the kicker field should be measured based on Faraday effect. The measurement has tested in the lab before install the experiment area. In this presentation, the simulation and measurement results will be discussed. This work was supported by IBS-R017-D1-2016-a00.
NASA Astrophysics Data System (ADS)
Zamora, J. C.; Aumann, T.; Bagchi, S.; Bönig, S.; Csatlós, M.; Dillmann, I.; Dimopoulou, C.; Egelhof, P.; Eremin, V.; Furuno, T.; Geissel, H.; Gernhäuser, R.; Harakeh, M. N.; Hartig, A.-L.; Ilieva, S.; Kalantar-Nayestanaki, N.; Kiselev, O.; Kollmus, H.; Kozhuharov, C.; Krasznahorkay, A.; Kröll, Th.; Kuilman, M.; Litvinov, S.; Litvinov, Yu. A.; Mahjour-Shafiei, M.; Mutterer, M.; Nagae, D.; Najafi, M. A.; Nociforo, C.; Nolden, F.; Popp, U.; Rigollet, C.; Roy, S.; Scheidenberger, C.; von Schmid, M.; Steck, M.; Streicher, B.; Stuhl, L.; Thürauf, M.; Uesaka, T.; Weick, H.; Winfield, J. S.; Winters, D.; Woods, P. J.; Yamaguchi, T.; Yue, K.; Zenihiro, J.
2017-09-01
A novel method for measuring nuclear reactions in inverse kinematics with stored ion beams was successfully used to extract the nuclear-matter radius of 58Ni. The experiment was performed at the experimental heavy-ion storage ring at the GSI facility using a stored 58Ni beam at energies of 100 and 150 MeV/u and an internal helium gas-jet target. Elastically scattered α -recoils at low momentum transfers were measured with an in-ring detector system compatible with ultrahigh vacuum. Experimental angular distributions were fitted using density-dependent optical model potentials within the eikonal approximation. This permitted the extraction of the point-matter root-mean-square radius of 58Ni with an average value of 3.70(7) fm. Results from this work are in good agreement with several experiments performed in the past in normal kinematics. This pioneering experiment demonstrates a major breakthrough towards future investigations with far-from-stability stored beams using the present technique.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Talman, Richard M.; Talman, John D.
Proposed methods for measuring the electric dipole moment (EDM) of the proton use an intense, polarized proton beam stored in an all-electric storage ring “trap.” At the “magic” kinetic energy of 232.792 MeV, proton spins are “frozen,” for example always parallel to the instantaneous particle momentum. Energy deviation from the magic value causes in-plane precession of the spin relative to the momentum. Any nonzero EDM value will cause out-of-plane precession—measuring this precession is the basis for the EDM determination. A proposed implementation of this measurement shows that a proton EDM value of 10 –29e–cm or greater will produce a statisticallymore » significant, measurable precession after multiply repeated runs, assuming small beam depolarization during 1000 s runs, with high enough precision to test models of the early universe developed to account for the present day particle/antiparticle population imbalance. This paper describes an accelerator simulation code, eteapot, a new component of the Unified Accelerator Libraries (ual), to be used for long term tracking of particle orbits and spins in electric bend accelerators, in order to simulate EDM storage ring experiments. Though qualitatively much like magnetic rings, the nonconstant particle velocity in electric rings gives them significantly different properties, especially in weak focusing rings. Like the earlier code teapot (for magnetic ring simulation) this code performs exact tracking in an idealized (approximate) lattice rather than the more conventional approach, which is approximate tracking in a more nearly exact lattice. The Bargmann-Michel-Telegdi (BMT) equation describing the evolution of spin vectors through idealized bend elements is also solved exactly—original to this paper. Furthermore the idealization permits the code to be exactly symplectic (with no artificial “symplectification”). Any residual spurious damping or antidamping is sufficiently small to permit reliable tracking for the long times, such as the 1000 s assumed in estimating the achievable EDM precision. This paper documents in detail the theoretical formulation implemented in eteapot. An accompanying paper describes the practical application of the eteapot code in the Universal Accelerator Libraries (ual) environment to “resurrect,” or reverse engineer, the “AGS-analog” all-electric ring built at Brookhaven National Laboratory in 1954. Of the (very few) all-electric rings ever commissioned, the AGS-analog ring is the only relativistic one and is the closest to what is needed for measuring proton (or, even more so, electron) EDM’s. As a result, the companion paper also describes preliminary lattice studies for the planned proton EDM storage rings as well as testing the code for long time orbit and spin tracking.« less
An undulator based soft x-ray source for microscopy on the Duke electron storage ring
NASA Astrophysics Data System (ADS)
Johnson, Lewis Elgin
1998-09-01
This dissertation describes the design, development, and installation of an undulator-based soft x-ray source on the Duke Free Electron Laser laboratory electron storage ring. Insertion device and soft x-ray beamline physics and technology are all discussed in detail. The Duke/NIST undulator is a 3.64-m long hybrid design constructed by the Brobeck Division of Maxwell Laboratories. Originally built for an FEL project at the National Institute of Standards and Technology, the undulator was acquired by Duke in 1992 for use as a soft x-ray source for the FEL laboratory. Initial Hall probe measurements on the magnetic field distribution of the undulator revealed field errors of more than 0.80%. Initial phase errors for the device were more than 11 degrees. Through a series of in situ and off-line measurements and modifications we have re-tuned the magnet field structure of the device to produce strong spectral characteristics through the 5th harmonic. A low operating K has served to reduce the effects of magnetic field errors on the harmonic spectral content. Although rms field errors remained at 0.75%, we succeeded in reducing phase errors to less than 5 degrees. Using trajectory simulations from magnetic field data, we have computed the spectral output given the interaction of the Duke storage ring electron beam and the NIST undulator. Driven by a series of concerns and constraints over maximum utility, personnel safety and funding, we have also constructed a unique front end beamline for the undulator. The front end has been designed for maximum throughput of the 1st harmonic around 40A in its standard mode of operation. The front end has an alternative mode of operation which transmits the 3rd and 5th harmonics. This compact system also allows for the extraction of some of the bend magnet produced synchrotron and transition radiation from the storage ring. As with any well designed front end system, it also provides excellent protection to personnel and to the storage ring. A diagnostic beamline consisting of a transmission grating spectrometer and scanning wire beam profile monitor was constructed to measure the spatial and spectral characteristics of the undulator radiation. Test of the system with a circulating electron beam has confirmed the magnetic and focusing properties of the undulator, and verified that it can be used without perturbing the orbit of the beam.
E-MSD: an integrated data resource for bioinformatics.
Velankar, S; McNeil, P; Mittard-Runte, V; Suarez, A; Barrell, D; Apweiler, R; Henrick, K
2005-01-01
The Macromolecular Structure Database (MSD) group (http://www.ebi.ac.uk/msd/) continues to enhance the quality and consistency of macromolecular structure data in the worldwide Protein Data Bank (wwPDB) and to work towards the integration of various bioinformatics data resources. One of the major obstacles to the improved integration of structural databases such as MSD and sequence databases like UniProt is the absence of up to date and well-maintained mapping between corresponding entries. We have worked closely with the UniProt group at the EBI to clean up the taxonomy and sequence cross-reference information in the MSD and UniProt databases. This information is vital for the reliable integration of the sequence family databases such as Pfam and Interpro with the structure-oriented databases of SCOP and CATH. This information has been made available to the eFamily group (http://www.efamily.org.uk/) and now forms the basis of the regular interchange of information between the member databases (MSD, UniProt, Pfam, Interpro, SCOP and CATH). This exchange of annotation information has enriched the structural information in the MSD database with annotation from wider sequence-oriented resources. This work was carried out under the 'Structure Integration with Function, Taxonomy and Sequences (SIFTS)' initiative (http://www.ebi.ac.uk/msd-srv/docs/sifts) in the MSD group.
Zhang, Zong-Yong; Jiang, Ming; Fang, Jie; Yang, Ming-Feng; Zhang, Shuai; Yin, Yan-Xin; Li, Da-Wei; Mao, Lei-Lei; Fu, Xiao-Yan; Hou, Ya-Jun; Fu, Xiao-Ting; Fan, Cun-Dong; Sun, Bao-Liang
2017-01-01
Curcumin and nano-curcumin both exhibit neuroprotective effects in early brain injury (EBI) after experimental subarachnoid hemorrhage (SAH). However, the mechanism that whether curcumin and its nanoparticles affect the blood-brain barrier (BBB) following SAH remains unclear. This study investigated the effect of curcumin and the poly(lactide-co-glycolide) (PLGA)-encapsulated curcumin nanoparticles (Cur-NPs) on BBB disruption and evaluated the possible mechanism underlying BBB dysfunction in EBI using the endovascular perforation rat SAH model. The results indicated that Cur-NPs showed enhanced therapeutic effects than that of curcumin in improving neurological function, reducing brain water content, and Evans blue dye extravasation after SAH. Mechanically, Cur-NPs attenuated BBB dysfunction after SAH by preventing the disruption of tight junction protein (ZO-1, occludin, and claudin-5). Cur-NPs also up-regulated glutamate transporter-1 and attenuated glutamate concentration of cerebrospinal fluid following SAH. Moreover, inhibition of inflammatory response and microglia activation both contributed to Cur-NPs' protective effects. Additionally, Cur-NPs markedly suppressed SAH-mediated oxidative stress and eventually reversed SAH-induced cell apoptosis in rats. Our findings revealed that the strategy of using Cur-NPs could be a promising way in improving neurological function in EBI after experimental rat SAH.
Shinsuke, Nishimura; Hiroshi, Inoue
2013-11-01
To identify the effect of an imbalance of Th1/Th2 cytokines on the development of autoimmune glomerulonephritis (lupus nephritis), we studied the modification of pathological changes in diffuse proliferative glomerulonephritis (DPGN) and membranous glomerulonephritis (MGN) in MRL/lpr mice, which are animal models of systemic lupus erythematosus (SLE). Transgenic MRL/lpr mice (Tg) that overexpressed Epstein--Barr virus-induced gene 3 (EBI3) showed almost normal renal function, which was demonstrated by healing of glomerulonephritis upon renal histology, as compared to the wild-type MRL/lpr (Wt) mice. The levels of anti-dsDNA antibodies and IgE decreased in the Tg mice compared to Wt mice. Quantitative real-time PCR indicated an increase in the mRNA levels of FoxP3, and a decrease in that of IFNγ in the splenocytes of Tg mice as compared to Wt mice. In addition, flow cytometric analysis showed an increase in CD4(+)CD25(+)FoxP3(+)-T cells in the former, as compared to the latter. Our findings suggest that EBI3-overexpression in MRL/lpr mice induces generation of regulatory T cells, which causes suppression of autoimmune and inflammatory reactions by affecting the Th1/Th2 cytokine balance.
The temporal distribution and carbon storage of large oak wood in streams and floodplain deposits
Richard P. Guyette; Daniel C. Dey; Michael C. Stambaugh
2008-01-01
We used tree-ring dating and 14C dating to document the temporal distribution and carbon storage of oak (Quercus spp.) wood in trees recruited and buried by streams and floodplains in northern Missouri, USA. Frequency distributions indicated that oak wood has been accumulating in Midwest streams continually since at least the...
NASA Astrophysics Data System (ADS)
Lei, Ming; Tian, Qing; Wu, Kevin; Zhao, Yan
2016-03-01
Gate to source/drain (S/D) short is the most common and detrimental failure mechanism for advanced process technology development in Metal-Oxide-Semiconductor-Field-Effect-Transistor (MOSFET) device manufacturing. Especially for sub-1Xnm nodes, MOSFET device is more vulnerable to gate-S/D shorts due to the aggressive scaling. The detection of this kind of electrical short defect is always challenging for in-line electron beam inspection (EBI), especially new shorting mechanisms on atomic scale due to new material/process flow implementation. The second challenge comes from the characterization of the shorts including identification of the exact shorting location. In this paper, we demonstrate unique scan direction induced charging dynamics (SDCD) phenomenon which stems from the transistor level response from EBI scan at post metal contact chemical-mechanical planarization (CMP) layers. We found that SDCD effect is exceptionally useful for gate-S/D short induced voltage contrast (VC) defect detection, especially for identification of shorting locations. The unique SDCD effect signatures of gate-S/D shorts can be used as fingerprint for ground true shorting defect detection. Correlation with other characterization methods on the same defective location from EBI scan shows consistent results from various shorting mechanism. A practical work flow to implement the application of SDCD effect for in-line EBI monitor of critical gate-S/D short defects is also proposed, together with examples of successful application use cases which mostly focus on static random-access memory (SRAM) array regions. Although the capability of gate-S/D short detection as well as expected device response is limited to passing transistors and pull-down transistors due to the design restriction from standard 6-cell SRAM structure, SDCD effect is proven to be very effective for gate-S/D short induced VC defect detection as well as yield learning for advanced technology development.
Kochetkova, Irina; Thornburg, Theresa; Callis, Gayle; Holderness, Kathryn; Maddaloni, Massimo; Pascual, David W.
2014-01-01
A Salmonella therapeutic expressing enterotoxigenic E. coli colonization factor antigen I (CFA/I) fimbriae protects against collagen-induced arthritis (CIA) by eliciting two regulatory T cell (Treg) subsets: TGF-β-producing Foxp3−CD39+CD4+ and IL-10-producing Foxp3+CD39+CD4+ T cells. However, it is unclear if CFA/I fimbriae alone are protective, and if other regulatory cytokines are involved especially in the context for the EBI3-sharing cytokines, Treg-derived IL-35 and APC-derived IL-27, both capable of suppressing Th17 cells and regulating autoimmune diseases. Subsequent evaluation revealed that a single oral dose of purified, soluble CFA/I fimbriae protected against CIA as effectively as Salmonella-CFA/I, and found Foxp3+CD39+CD4+ T cells as the source of secreted IL-35, whereas IL-27 production by CD11c+ cells was inhibited. Inquiring into their relevance, CFA/I fimbriae-treated IL-27 receptor-deficient (WSX-1−/−) mice were equally protected against CIA as wild-type mice suggesting a limited role for IL-27. In contrast, CFA/I fimbriae-mediated protection was abated in EBI3−/− mice accompanied by the loss of TGF-β- and IL-10-producing Tregs. Adoptive transfer of B6 CD39+CD4+ T cells to EBI3−/− mice with concurrent CFA/I plus IL-35 treatment effectively stimulated Tregs suppressing proinflammatory CII-specific Th cells. Opposingly, recipients co-transferred with B6 and EBI3−/− CD39+CD4+ T cells and treated with CFA/I plus IL-35 failed in protecting mice implicating the importance for endogenous IL-35 to confer CFA/I-mediated protection. Thus, CFA/I fimbriae stimulate IL-35 required for the co-induction of TGF-β and IL-10. PMID:24337375
A FODO racetrack ring for nuSTORM: design and optimization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, A.; Bross, A.; Neuffer, D.
2017-07-01
The goal of nuSTORM is to provide well-defined neutrino beams for precise measurements of neutrino cross-sections and oscillations. The nuSTORM decay ring is a compact racetrack storage ring with a circumference of ~ 480 m that incorporates large aperture (60 cm diameter) magnets. There are many challenges in the design. In order to incorporate the Orbit Combination section (OCS), used for injecting the pion beam into the ring, a dispersion suppressor is needed adjacent to the OCS . Concurrently, in order to maximize the number of useful muon decays, strong bending dipoles are needed in the arcs to minimize the arcmore » length. These dipoles create strong chromatic effects, which need to be corrected by nonlinear sextupole elements in the ring. In this paper, a FODO racetrack ring design and its optimization using sextupolar fields via both a Genetic Algorithm (GA) and a Simulated Annealing (SA) algorithm will be discussed.« less
Sensory acceptability of squid rings gamma irradiated for shelf-life extension
NASA Astrophysics Data System (ADS)
Tomac, Alejandra; Cova, María C.; Narvaiz, Patricia; Yeannes, María I.
2017-01-01
The feasibility of extending the shelf-life of a squid product by gamma irradiation was analyzed. Illex argentinus rings were irradiated at 4 and 8 kGy; and stored at 4±1 °C during 77 days. No mesophilic bacteria, enterobacteriaceae and coliforms were detected in irradiated rings during storage. Psychrotrophic bacteria were significantly reduced by irradiation; their counts were fitted to a growth model which was further used for shelf-life estimations: 3 and 27 days for 0 and 4 kGy, respectively. Initially, non-irradiated as well as irradiated rings had very good sensory scores. The overall acceptability of 4 and 8 kGy rings did not decrease during 27 and 64 days, respectively, while control samples spoiled after 3 days. A radiation dose range for squid rings preservation was defined, which attained the technological shelf-life extension objective, without impairing sensory quality.
Correction to AD/RHIC-47, Beam Transfer From AGS to RHIC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Claus, J.; Foelsche, H.
1988-12-12
RHIC an acronym for Relativistic Heavy Ion Collider, is a facility for colliding heavy ions with each other, proposed for construction at Brookhaven National Laboratory. This facility and the motivation for building it, have been described. It consists of two intersecting storage rings and the purpose of this note is to describe how these two rings are to be filled with beam.
Simulation of emittance dilution in electron storage ring from Compton backscattering
NASA Astrophysics Data System (ADS)
Blumberg, L. N.; Blum, E.
A Monte-Carlo simulation of Compton backscattered kappa(sub L) = 3.2-micron photons from an IR-FEL on 75-MeV electrons in a storage ring yields an RMS electron energy spread of delta(sub E) = 11.9-keV for a sample of 10(exp 7) single scattering events. Electrons are sampled from a beam of natural energy spread sigma(sub E) = 5.6-keV and damped transverse angle spreads sigma(sub x)(prime) = .041-mrad and sigma(sub y)(prime) = .052-mrad (100%) coupling, scaled from the 200-MeV BNL XLS compact storage ring. The Compton-scattered x-rays are generated from an integral of the CM Klein-Nishina cross-section transformed to the lab. A tracking calculation has also been performed in 6-dimensional phase space. Initial electron coordinates are selected randomly from a Gaussian distribution of RMS spreads sigma(sub xo) = .102-mm, sigma(sub x(prime)o) = .041-mrad, sigma(sub yo) = .018-mm, sigma(sub y(prime)o) = .052-mrad, sigma(sub (phi)o) = 22-mrad and sigma(sub Eo) = 6-keV. A sample of 10000 electrons were each following for 40000 turns around the ring through an RF cavity of f(sub RF) = 211.54-MHz and peak voltage V(sub m)=300-keV. Preliminary results indicate that the resulting energy distribution is quite broad with an RMS width of delta(sub E) = 124-keV. The transverse widths are only slightly increased from their original values, i.e. delta(sub x) = .106-mm and delta(sub x)(prime) = .043 mrad. The scaled energy spread of delta(sub E) approximately = 360-keV for approximately 350,000 turns desired in a 10-msec x-ray angiography exposure is well within the RF bucket used here; even V(sub m) less than 50-kV is adequate. Further, the electron energy spread adds a negligible RMS x-ray energy spread of delta(sub Ex) = .32-keV. The electron energy damping time of tau(sub E) = 379-msec at 75-MeV in an XLS-type ring allows for damping this induced spread and top-off of the ring between heart cycles.
A rule-based ontological framework for the classification of molecules
2014-01-01
Background A variety of key activities within life sciences research involves integrating and intelligently managing large amounts of biochemical information. Semantic technologies provide an intuitive way to organise and sift through these rapidly growing datasets via the design and maintenance of ontology-supported knowledge bases. To this end, OWL—a W3C standard declarative language— has been extensively used in the deployment of biochemical ontologies that can be conveniently organised using the classification facilities of OWL-based tools. One of the most established ontologies for the chemical domain is ChEBI, an open-access dictionary of molecular entities that supplies high quality annotation and taxonomical information for biologically relevant compounds. However, ChEBI is being manually expanded which hinders its potential to grow due to the limited availability of human resources. Results In this work, we describe a prototype that performs automatic classification of chemical compounds. The software we present implements a sound and complete reasoning procedure of a formalism that extends datalog and builds upon an off-the-shelf deductive database system. We capture a wide range of chemical classes that are not expressible with OWL-based formalisms such as cyclic molecules, saturated molecules and alkanes. Furthermore, we describe a surface ‘less-logician-like’ syntax that allows application experts to create ontological descriptions of complex biochemical objects without prior knowledge of logic. In terms of performance, a noticeable improvement is observed in comparison with previous approaches. Our evaluation has discovered subsumptions that are missing from the manually curated ChEBI ontology as well as discrepancies with respect to existing subclass relations. We illustrate thus the potential of an ontology language suitable for the life sciences domain that exhibits a favourable balance between expressive power and practical feasibility. Conclusions Our proposed methodology can form the basis of an ontology-mediated application to assist biocurators in the production of complete and error-free taxonomies. Moreover, such a tool could contribute to a more rapid development of the ChEBI ontology and to the efforts of the ChEBI team to make annotated chemical datasets available to the public. From a modelling point of view, our approach could stimulate the adoption of a different and expressive reasoning paradigm based on rules for which state-of-the-art and highly optimised reasoners are available; it could thus pave the way for the representation of a broader spectrum of life sciences and biomedical knowledge. PMID:24735706
A rule-based ontological framework for the classification of molecules.
Magka, Despoina; Krötzsch, Markus; Horrocks, Ian
2014-01-01
A variety of key activities within life sciences research involves integrating and intelligently managing large amounts of biochemical information. Semantic technologies provide an intuitive way to organise and sift through these rapidly growing datasets via the design and maintenance of ontology-supported knowledge bases. To this end, OWL-a W3C standard declarative language- has been extensively used in the deployment of biochemical ontologies that can be conveniently organised using the classification facilities of OWL-based tools. One of the most established ontologies for the chemical domain is ChEBI, an open-access dictionary of molecular entities that supplies high quality annotation and taxonomical information for biologically relevant compounds. However, ChEBI is being manually expanded which hinders its potential to grow due to the limited availability of human resources. In this work, we describe a prototype that performs automatic classification of chemical compounds. The software we present implements a sound and complete reasoning procedure of a formalism that extends datalog and builds upon an off-the-shelf deductive database system. We capture a wide range of chemical classes that are not expressible with OWL-based formalisms such as cyclic molecules, saturated molecules and alkanes. Furthermore, we describe a surface 'less-logician-like' syntax that allows application experts to create ontological descriptions of complex biochemical objects without prior knowledge of logic. In terms of performance, a noticeable improvement is observed in comparison with previous approaches. Our evaluation has discovered subsumptions that are missing from the manually curated ChEBI ontology as well as discrepancies with respect to existing subclass relations. We illustrate thus the potential of an ontology language suitable for the life sciences domain that exhibits a favourable balance between expressive power and practical feasibility. Our proposed methodology can form the basis of an ontology-mediated application to assist biocurators in the production of complete and error-free taxonomies. Moreover, such a tool could contribute to a more rapid development of the ChEBI ontology and to the efforts of the ChEBI team to make annotated chemical datasets available to the public. From a modelling point of view, our approach could stimulate the adoption of a different and expressive reasoning paradigm based on rules for which state-of-the-art and highly optimised reasoners are available; it could thus pave the way for the representation of a broader spectrum of life sciences and biomedical knowledge.
NASA Astrophysics Data System (ADS)
Jahren, H.; Sternberg, L.
2005-12-01
Fossil tree rings from Axel Heiberg Island were microanalyzed for δ13C value in order to assess patterns of tree growth and carbon storage within the Middle Eocene (~45 Ma) Arctic paleoenvironment. Wood from four Metasequoia-type individuals was subsampled for analysis: each individual fossil consisted of between 4 and 10 large (~1 cm thick) consecutive tree rings. One of the fossils displayed an obvious concentric pattern, allowing for the determination of the direction of growth with isotopic pattern. Each ring was divided into ~1 mm thick subsamples, resulting in 5-10 δ13C value determinations per period of ring growth (i.e., growing season). All rings revealed a distinct pattern that was characteristic across growing seasons and across individual fossils. Early in the season, δ13C was at its highest value but descended systematically and sharply to its lowest value at the end of the growing season. Total decrease ranged between 3 and 5 ‰ over the course of each growing season. Identical patterns were observed in the δ13C value of alpha-cellulose isolated from each subsample, indicating that the trends observed did not represent changing levels of secondary metabolites, but rather a seasonal adjustment in the bulk source of carbon used during biosynthesis. Our results are consistent with the following annual pattern of wood synthesis 1.) complete dependence on the mobilization of stored carbon compounds early in the growing season; 2.) systematically increasing use of actively-acquired photosynthate during the growing season; 3.) complete reliance on active photosynthate by the end of the growing season. An additional and significant source of 13C discrimination is declining light levels late in the growing season, and likely contributes to the extreme pattern of δ13C decrease seen across each ring. Our results mimic those seen from modern broadleaf deciduous trees (Helle & Schlesser 2004), but differ from those seen in modern conifers (Barbour et al 2002), underlining the important influence of dormancy, storage and changing light levels on carbon cycling within the Paleogene polar forests. Helle & Schleser 2004: Plant, Cell and Environment 27:367-380. Barbour, Walcroft & Farquhar 2002: Plant, Cell and Environment 25: 1483-1499.
The design improvement of horizontal stripline kicker in TPS storage ring
NASA Astrophysics Data System (ADS)
Chou, P. J.; Chan, C. K.; Chang, C. C.; Hsu, K. T.; Hu, K. H.; Kuan, C. K.; Sheng, I. C.
2017-07-01
We plan to replace the existing horizontal stripline kicker of the transverse feedback system with an improved design. Large reflected power was observed at the downstream port of stripline kicker driven by the feedback amplifier. A rapid surge of vacuum pressure was observed when we tested the high current operation in TPS storage ring in April 2016. A burned feedthrough of the horizontal stripline kicker was discovered during a maintenance shutdown. The improved design is targeted to reduce the reflection of driving power from feedback system and to reduce beam induced RF heating. This major modification of the design is described. The results of RF simulation performed with the electromagnetic code GdfidL are reported as well.
Impact parameter sensitive study of inner-shell atomic processes in the experimental storage ring
NASA Astrophysics Data System (ADS)
Gumberidze, A.; Kozhuharov, C.; Zhang, R. T.; Trotsenko, S.; Kozhedub, Y. S.; DuBois, R. D.; Beyer, H. F.; Blumenhagen, K.-H.; Brandau, C.; Bräuning-Demian, A.; Chen, W.; Forstner, O.; Gao, B.; Gassner, T.; Grisenti, R. E.; Hagmann, S.; Hillenbrand, P.-M.; Indelicato, P.; Kumar, A.; Lestinsky, M.; Litvinov, Yu. A.; Petridis, N.; Schury, D.; Spillmann, U.; Trageser, C.; Trassinelli, M.; Tu, X.; Stöhlker, Th.
2017-10-01
In this work, we present a pilot experiment in the experimental storage ring (ESR) at GSI devoted to impact parameter sensitive studies of inner shell atomic processes for low-energy (heavy-) ion-atom collisions. The experiment was performed with bare and He-like xenon ions (Xe54+, Xe52+) colliding with neutral xenon gas atoms, resulting in a symmetric collision system. This choice of the projectile charge states was made in order to compare the effect of a filled K-shell with the empty one. The projectile and target X-rays have been measured at different observation angles for all impact parameters as well as for the impact parameter range of ∼35-70 fm.
Ultrashort high-brightness pulses from storage rings
NASA Astrophysics Data System (ADS)
Khan, Shaukat
2017-09-01
The brightness of short-wavelength radiation from accelerator-based sources can be increased by coherent emission in which the radiation intensity scales with the number of contributing electrons squared. This requires a microbunched longitudinal electron distribution, which is the case in free-electron lasers. The brightness of light sources based on electron storage rings was steadily improved, but could profit further from coherent emission. The modulation of the electron energy by a continuous-wave laser field may provide steady-state microbunching in the infrared regime. For shorter wavelengths, the energy modulation can be converted into a temporary density modulation by a dispersive chicane. One particular goal is coherent emission from a very short "slice" within an electron bunch in order to produce ultrashort radiation pulses with high brightness.
Astrochemistry at the Cryogenic Storage Ring
NASA Astrophysics Data System (ADS)
Kreckel, Holger; Becker, Arno; Blaum, Klaus; Breitenfeldt, Christian; George, Sebastian; Göck, Jürgen; Grieser, Manfred; Grussie, Florian; Guerin, Elisabeth; Heber, Oded; Karthein, Jonas; Krantz, Claude; Meyer, Christian; Mishra, Preeti; Novotny, Oldrich; O'Connor, Aodh; Saurabh, Sunny; Schippers, Stefan; Spruck, Kaija; Kumar, S. Sunil; Urbain, Xavier; Vogel, Stephen; von Hahn, Robert; Wilhelm, Patrick; Wolf, Andreas; Zajfman, Daniel
2017-01-01
Almost 200 different molecular species have been identified in space, and this number continues to grow steadily. This surprising molecular diversity bears witness to an active reaction network, in which molecular ions are the main drivers of chemistry in the gas phase. To study these reactions under controlled conditions in the laboratory is a major experimental challenge. The new Cryogenic Storage Ring (CSR) that has recently been commissioned at the Max Planck Institute for Nuclear Physics in Heidelberg will serve as an ideal testbed to study cold molecular ions in the gas phase. With residual gas densities of <140 cm-3 and temperatures below 10K, the CSR will allow for merged beams collision studies involving molecular ions, neutral atoms, free electrons and photons under true interstellar conditions.
Rachek, I. A.; Arrington, J.; Dmitriev, V. F.; ...
2015-02-12
The ratio of the elastic e +p to e –p scattering cross sections has been measured precisely, allowing the determination of the two-photon exchange contribution to these processes. This neglected contribution is believed to be the cause of the discrepancy between the Rosenbluth and polarization transfer methods of measuring the proton electromagnetic form factors. The experiment was performed at the VEPP-3 storage ring at beam energies of 1.6 and 1.0 GeV and at lepton scattering angles between 15° and 105°. The data obtained show evidence of a significant two-photon exchange effect. Furthermore, the results are compared with several theoretical predictions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferro-Luzzi, M.; Bouwhuis, M.; Passchier, E.
1996-09-01
We report an absolute measurement of the tensor analyzing powers {ital T}{sub 20} and {ital T}{sub 22} in elastic electron-deuteron scattering at a momentum transfer of 1.6 fm{sup {minus}1}. The novel approach of this measurement is the use of a tensor polarized {sup 2}H target internal to an electron storage ring, with {ital in} {ital situ} measurement of the polarization of the target gas. Scattered electrons and recoil deuterons were detected in coincidence with two large acceptance nonmagnetic detectors. The techniques demonstrated have broad applicability to further measurements of spin-dependent electron scattering. {copyright} {ital 1996 The American Physical Society.}
ALS superbend magnet performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marks, Steve; Zbasnik, John; Byrne, Warren
2001-12-10
The Lawrence Berkeley National Laboratory has been engaged in the design, construction and testing of four superconducting dipoles (Superbends) that are installed in three arcs of the Advanced Light Source (ALS), with the fourth magnet as a spare. This represents a major upgrade to the ALS providing an enhanced flux and brightness at photon energies above 10 keV. In preparation for installation, an extensive set of tests and measurements have been conducted to characterize the magnetic and cryogenic performance of the Superbends and to fiducialize them for accurate placement in the ALS storage ring. The magnets are currently installed, andmore » the storage ring is undergoing final commissioning. This paper will present the results of magnetic and cryogenic testing.« less
Research and Development on the Storage Ring Vacuum System for the APS Upgrade Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stillwell, B.; Brajuskovic, B.; Carter, J.
A number of research and development activities are underway at Argonne National Laboratory to build confidence in the designs for the storage ring vacuum system required for the Advanced Photon Source Up-grade project (APS-U) [1]. The predominant technical risks are: excessive residual gas pressures during operation; insufficient beam position monitor stability; excessive beam impedance; excessive heating by induced electrical surface currents; and insufficient operational reliability. Present efforts to mitigate these risks include: building and evaluating mockup assemblies; performing mechanical testing of chamber weld joints; developing computational tools; investigating design alternatives; and performing electrical bench measurements. Status of these activities andmore » some of what has been learned to date will be shared.« less
Schmitt, Thorsten; de Groot, Frank M F; Rubensson, Jan Erik
2014-09-01
The spectroscopic technique of resonant inelastic X-ray scattering (RIXS) will particularly profit from immensely improved brilliance of diffraction-limited storage rings (DLSRs). In RIXS one measures the intensities of excitations as a function of energy and momentum transfer. DLSRs will allow for pushing the achievable energy resolution, signal intensity and the sampled spot size to new limits. With RIXS one nowadays probes a broad range of electronic systems reaching from simple molecules to complex materials displaying phenomena like peculiar magnetism, two-dimensional electron gases, superconductivity, photovoltaic energy conversion and heterogeneous catalysis. In this article the types of improved RIXS studies that will become possible with X-ray beams from DLSRs are envisioned.
FY2017 status report: Model 9975 O-ring fixture long-term leak performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W. L.
A series of experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the Model 9975 shipping package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperature. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially andmore » have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, a smaller test matrix with fourteen additional tests was initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. Leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The 300 °F GLT O-ring fixtures failed after 2.8 to 5.7 years at temperature. The remaining GLT O-ring fixtures aging at 300 ºF were retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 9 to 10.5 years, or in GLT O-ring fixtures aging at 270 ºF for 5.7 years. These aging temperatures bound O-ring temperatures anticipated during normal storage in K-Area Complex (KAC). Leak test failures have been experienced in all of the GLT-S O-ring fixtures aging at 300 ºF and above. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 ºF for 6.9 to 7.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty still exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicates margin remains for O-rings still in service. Aging and periodic leak testing will continue for the remaining PCV fixtures.« less
Upgrades at the Duke Free Electron Laser Laboratory
NASA Astrophysics Data System (ADS)
Howell, Calvin R.
2004-11-01
Major upgrades to the storage-ring based photon sources at the Duke Free Electron Laser Laboratory (DFELL) are underway. The photon sources at the DFELL are well suited for research in the areas of medicine, biophysics, accelerator physics, nuclear physics and material science. These upgrades, which will be completed by the summer 2006, will significantly enhance the capabilities of the ultraviolet (UV) free-electron laser (FEL) and the high intensity gamma-ray source (HIGS). The HIGS is a relatively new research facility at the DFELL that is operated jointly by the DFELL and the Triangle Universities Nuclear Laboratory. The gamma-ray beam is produced by Compton back scattering of the UV photons inside the FEL optical cavity off the circulating electrons in the storage ring. The gamma-ray beam is 100% polarized and its energy resolution is selected by collimation. The capabilities of the upgraded facility will be described, the status of the upgrades will be summarized, and the proposed first-generation research program at HIGS will be presented.
Next Generation Muon g-2 Experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hertzog, David W.
2015-12-02
I report on the progress of two new muon anomalous magnetic moment experiments, which are in advanced design and construction phases. The goal of Fermilab E989 is to reduce the experimental uncertainty ofmore » $$a_\\mu$$ from Brookhaven E821 by a factor of 4; that is, $$\\delta a_\\mu \\sim 16 \\times 10^{-11}$$, a relative uncertainty of 140~ppb. The method follows the same magic-momentum storage ring concept used at BNL, and pioneered previously at CERN, but muon beam preparation, storage ring internal hardware, field measuring equipment, and detector and electronics systems are all new or upgraded significantly. In contrast, J-PARC E34 will employ a novel approach based on injection of an ultra-cold, low-energy, muon beam injected into a small, but highly uniform magnet. Only a small magnetic focusing field is needed to maintain storage, which distinguishes it from CERN, BNL and Fermilab. E34 aims to roughly match the previous BNL precision in their Phase~1 installation.« less
Reducing Our Carbon Footprint: Converting Plants to Fuel (LBNL Science at the Theater)
Somerville, Chris [Univ. of California, Berkeley, CA (United States)
2018-05-23
Berkeley Lab's Chris Somerville is a leading authority on the structure and function of plant cell walls, which comprise most of the body mass of higher plants. He views the knowledge of cell wall structure and function as furthering the development of plants with improved usefulness: these plants are strong potential sources of renewable materials and biofuel feedstocks. His scientific expertise defines an ideal match of his interest - in the development of cellulosic and other solar-to-fuel science - with his recent appointment as Director of the Energy Biosciences Institute (EBI). With colleagues in biology, physical sciences, engineering, and environmental and the social sciences, he now leads the EBI multidisciplinary teams' research efforts to develop next-generation, carbon-neutral transportation fuels.
ProtVista: visualization of protein sequence annotations.
Watkins, Xavier; Garcia, Leyla J; Pundir, Sangya; Martin, Maria J
2017-07-01
ProtVista is a comprehensive visualization tool for the graphical representation of protein sequence features in the UniProt Knowledgebase, experimental proteomics and variation public datasets. The complexity and relationships in this wealth of data pose a challenge in interpretation. Integrative visualization approaches such as provided by ProtVista are thus essential for researchers to understand the data and, for instance, discover patterns affecting function and disease associations. ProtVista is a JavaScript component released as an open source project under the Apache 2 License. Documentation and source code are available at http://ebi-uniprot.github.io/ProtVista/ . martin@ebi.ac.uk. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.
Performance on the low charge state laser ion source in BNL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Okamura, M.; Alessi, J.; Beebe, E.
On March 2014, a Laser Ion Source (LIS) was commissioned which delivers high-brightness, low-charge-state heavy ions for the hadron accelerator complex in Brookhaven National Laboratory (BNL). Since then, the LIS has provided many heavy ion species successfully. The low-charge-state (mostly singly charged) beams are injected to the Electron Beam Ion Source (EBIS), where ions are then highly ionized to fit to the following accelerator’s Q/M acceptance, like Au 32+. Recently we upgraded the LIS to be able to provide two different beams into EBIS on a pulse-to-pulse basis. Now the LIS is simultaneously providing beams for both the Relativistic Heavymore » Ion Collider (RHIC) and NASA Space Radiation Laboratory (NSRL).« less
The Ensembl REST API: Ensembl Data for Any Language
Yates, Andrew; Beal, Kathryn; Keenan, Stephen; McLaren, William; Pignatelli, Miguel; Ritchie, Graham R. S.; Ruffier, Magali; Taylor, Kieron; Vullo, Alessandro; Flicek, Paul
2015-01-01
Motivation: We present a Web service to access Ensembl data using Representational State Transfer (REST). The Ensembl REST server enables the easy retrieval of a wide range of Ensembl data by most programming languages, using standard formats such as JSON and FASTA while minimizing client work. We also introduce bindings to the popular Ensembl Variant Effect Predictor tool permitting large-scale programmatic variant analysis independent of any specific programming language. Availability and implementation: The Ensembl REST API can be accessed at http://rest.ensembl.org and source code is freely available under an Apache 2.0 license from http://github.com/Ensembl/ensembl-rest. Contact: ayates@ebi.ac.uk or flicek@ebi.ac.uk Supplementary information: Supplementary data are available at Bioinformatics online. PMID:25236461
Spin Pit Application of Image Derotated Holographic Interferometry.
1980-09-01
temperatures resulting from induction heating of the test structuore through the interaction of the electromagnets and the magnetic ring. Subsequent...reference beam, and a Tektronix Model 7633 storage oscilloscope. When the laser is fired, a trigger signal from the laser power supply initiates the...rapid induction heating of the test structure due to the interaction of the electromagnets and the magnetic ring was evi(lent with the switch from dc to
Diagnostic Systems Plan for the Advanced Light Source Top-OffUpgrade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barry, Walter; Chin, Mike; Robin, David
2005-05-10
The Advanced Light Source (ALS) will soon be upgraded to enable top-off operations [1], in which electrons are quasi-continuously injected to produce constant stored beam current. The upgrade is structured in two phases. First, we will upgrade our injector from 1.5 GeV to 1.9 GeV to allow full energy injection and will start top-off operations. In the second phase, we will upgrade the Booster Ring (BR) with a bunch cleaning system to allow high bunch purity top-off injection. A diagnostics upgrade will be crucial for success in both phases of the top-off project, and our plan for it is describedmore » in this paper. New booster ring diagnostics will include updated beam position monitor (BPM) electronics, a tune monitoring system, and a new scraper. Two new synchrotron light monitors and a beam stop will be added to the booster-to-storage ring transfer line (BTS), and all the existing beam current monitors along the accelerator chain will be integrated into a single injection efficiency monitoring application. A dedicated bunch purity monitor will be installed in the storage ring (SR). Together, these diagnostic upgrades will enable smooth commissioning of the full energy injector and a quick transition to high quality top-off operation at the ALS.« less
The cryogenic storage ring CSR
NASA Astrophysics Data System (ADS)
von Hahn, R.; Becker, A.; Berg, F.; Blaum, K.; Breitenfeldt, C.; Fadil, H.; Fellenberger, F.; Froese, M.; George, S.; Göck, J.; Grieser, M.; Grussie, F.; Guerin, E. A.; Heber, O.; Herwig, P.; Karthein, J.; Krantz, C.; Kreckel, H.; Lange, M.; Laux, F.; Lohmann, S.; Menk, S.; Meyer, C.; Mishra, P. M.; Novotný, O.; O'Connor, A. P.; Orlov, D. A.; Rappaport, M. L.; Repnow, R.; Saurabh, S.; Schippers, S.; Schröter, C. D.; Schwalm, D.; Schweikhard, L.; Sieber, T.; Shornikov, A.; Spruck, K.; Sunil Kumar, S.; Ullrich, J.; Urbain, X.; Vogel, S.; Wilhelm, P.; Wolf, A.; Zajfman, D.
2016-06-01
An electrostatic cryogenic storage ring, CSR, for beams of anions and cations with up to 300 keV kinetic energy per unit charge has been designed, constructed, and put into operation. With a circumference of 35 m, the ion-beam vacuum chambers and all beam optics are in a cryostat and cooled by a closed-cycle liquid helium system. At temperatures as low as (5.5 ± 1) K inside the ring, storage time constants of several minutes up to almost an hour were observed for atomic and molecular, anion and cation beams at an energy of 60 keV. The ion-beam intensity, energy-dependent closed-orbit shifts (dispersion), and the focusing properties of the machine were studied by a system of capacitive pickups. The Schottky-noise spectrum of the stored ions revealed a broadening of the momentum distribution on a time scale of 1000 s. Photodetachment of stored anions was used in the beam lifetime measurements. The detachment rate by anion collisions with residual-gas molecules was found to be extremely low. A residual-gas density below 140 cm-3 is derived, equivalent to a room-temperature pressure below 10-14 mbar. Fast atomic, molecular, and cluster ion beams stored for long periods of time in a cryogenic environment will allow experiments on collision- and radiation-induced fragmentation processes of ions in known internal quantum states with merged and crossed photon and particle beams.
The cryogenic storage ring CSR.
von Hahn, R; Becker, A; Berg, F; Blaum, K; Breitenfeldt, C; Fadil, H; Fellenberger, F; Froese, M; George, S; Göck, J; Grieser, M; Grussie, F; Guerin, E A; Heber, O; Herwig, P; Karthein, J; Krantz, C; Kreckel, H; Lange, M; Laux, F; Lohmann, S; Menk, S; Meyer, C; Mishra, P M; Novotný, O; O'Connor, A P; Orlov, D A; Rappaport, M L; Repnow, R; Saurabh, S; Schippers, S; Schröter, C D; Schwalm, D; Schweikhard, L; Sieber, T; Shornikov, A; Spruck, K; Sunil Kumar, S; Ullrich, J; Urbain, X; Vogel, S; Wilhelm, P; Wolf, A; Zajfman, D
2016-06-01
An electrostatic cryogenic storage ring, CSR, for beams of anions and cations with up to 300 keV kinetic energy per unit charge has been designed, constructed, and put into operation. With a circumference of 35 m, the ion-beam vacuum chambers and all beam optics are in a cryostat and cooled by a closed-cycle liquid helium system. At temperatures as low as (5.5 ± 1) K inside the ring, storage time constants of several minutes up to almost an hour were observed for atomic and molecular, anion and cation beams at an energy of 60 keV. The ion-beam intensity, energy-dependent closed-orbit shifts (dispersion), and the focusing properties of the machine were studied by a system of capacitive pickups. The Schottky-noise spectrum of the stored ions revealed a broadening of the momentum distribution on a time scale of 1000 s. Photodetachment of stored anions was used in the beam lifetime measurements. The detachment rate by anion collisions with residual-gas molecules was found to be extremely low. A residual-gas density below 140 cm(-3) is derived, equivalent to a room-temperature pressure below 10(-14) mbar. Fast atomic, molecular, and cluster ion beams stored for long periods of time in a cryogenic environment will allow experiments on collision- and radiation-induced fragmentation processes of ions in known internal quantum states with merged and crossed photon and particle beams.
The insertion device magnetic measurement facility: Prototype and operational procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burkel, L.; Dejus, R.; Maines, J.
1993-03-01
This report is a description of the current status of the magnetic measurement facility and is a basic instructional manual for the operation of the facility and its components. Please refer to the appendices for more detailed information about specific components and procedures. The purpose of the magnetic measurement facility is to take accurate measurements of the magnetic field in the gay of the IDs in order to determine the effect of the ID on the stored particle beam and the emitted radiation. The facility will also play an important role when evaluating new ideas, novel devices, and inhouse prototypesmore » as part of the ongoing research and development program at the APS. The measurements will be performed with both moving search coils and moving Hall probes. The IDs will be evaluated by computer modeling of the emitted radiation for any given (measured) magnetic field map. The quality of the magnetic field will be described in terms of integrated multipoles for the effect on Storage Ring performance and in terms of the derived trajectories for the emitted radiation. Before being installed on the Storage Ring, every device will be measured and characterized to assure that it is compatible with Storage Ring requirements and radiation specifications. The accuracy that the APS needs to achieve for magnetic measurements will be based on these specifications.« less
Magnet design for a low-emittance storage ring
Johansson, Martin; Anderberg, Bengt; Lindgren, Lars-Johan
2014-01-01
The MAX IV 3 GeV storage ring, currently under construction, pursues the goal of low electron beam emittance by using a multi-bend achromat magnet lattice, which is realised by having several consecutive magnet elements precision-machined out of a common solid iron block, 2.3–3.4 m long. With this magnet design solution, instead of having 1320 individual magnets, the MAX IV 3 GeV storage ring is built up using 140 integrated ‘magnet block’ units, containing all these magnet elements. Major features of this magnet block design are compactness, vibration stability and that the alignment of magnet elements within each unit is given by the mechanical accuracy of the CNC machining rather than individual field measurement and adjustment. This article presents practical engineering details of implementing this magnet design solution, and mechanical + magnetic field measurement results from the magnet production series. At the time of writing (spring 2014), the production series, which is totally outsourced to industry, is roughly half way through, with mechanical/magnetic QA conforming to specifications. It is the conclusion of the authors that the MAX IV magnet block concept, which has sometimes been described as new or innovative, is from a manufacturing point of view simply a collection of known mature production methods and measurement procedures, which can be executed at fixed cost with a low level of risk. PMID:25177980
Code comparison for accelerator design and analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parsa, Z.
1988-01-01
We present a comparison between results obtained from standard accelerator physics codes used for the design and analysis of synchrotrons and storage rings, with programs SYNCH, MAD, HARMON, PATRICIA, PATPET, BETA, DIMAD, MARYLIE and RACE-TRACK. In our analysis we have considered 5 (various size) lattices with large and small angles including AGS Booster (10/degree/ bend), RHIC (2.24/degree/), SXLS, XLS (XUV ring with 45/degree/ bend) and X-RAY rings. The differences in the integration methods used and the treatment of the fringe fields in these codes could lead to different results. The inclusion of nonlinear (e.g., dipole) terms may be necessary inmore » these calculations specially for a small ring. 12 refs., 6 figs., 10 tabs.« less
TSR: A storage and cooling ring for HIE-ISOLDE
NASA Astrophysics Data System (ADS)
Butler, P. A.; Blaum, K.; Davinson, T.; Flanagan, K.; Freeman, S. J.; Grieser, M.; Lazarus, I. H.; Litvinov, Yu. A.; Lotay, G.; Page, R. D.; Raabe, R.; Siesling, E.; Wenander, F.; Woods, P. J.
2016-06-01
It is planned to install the heavy-ion, low-energy ring TSR, currently at the Max-Planck-Institute for Nuclear Physics in Heidelberg, at the HIE-ISOLDE facility in CERN, Geneva. Such a facility will provide a capability for experiments with stored, cooled secondary beams that is rich and varied, spanning from studies of nuclear ground-state properties and reaction studies of astrophysical relevance, to investigations with highly-charged ions and pure isomeric beams. In addition to experiments performed using beams recirculating within the ring, the cooled beams can be extracted and exploited by external spectrometers for high-precision measurements. The capabilities of the ring facility as well as some physics cases will be presented, together with a brief report on the status of the project.
Preveena, Jagadesan; Bhore, Subhash J
2013-01-01
In traditional medicine, Tridax procumbens Linn. is used in the treatment of injuries and wounds. The bacterial endophytes (BEs) of medicinal plants could produce medicinally important metabolites found in their hosts; and hence, the involvement of BEs in conferring wound healing properties to T. Procumbens cannot be ruled out. But, we do not know which types of BEs are associated with T. Procumbens. The objective of this study was to investigate the fast growing and cultivable BEs associated with T. procumbens. Leaves and stems of healthy T. Procumbens plants were collected and cultivable BEs were isolated from surface-sterilized leaf and stem tissue samples using Luria-Bertani (LB) agar (medium) at standard conditions. A polymerase chain reaction was employed to amplify 16S rRNA coding gene fragments from the isolates. Cultivable endophytic bacterial isolates (EBIs) were identified using 16S rRNA gene nucleotide sequence similarity based method of bacterial identification. Altogether, 50 culturable EBIs were isolated. 16S rRNA gene nucleotide sequences analysis using the Basic Local Alignment Search Tool (BLAST) revealed identities of the EBIs. Analysis reveals that cultivable Bacillus spp., Cronobacter sakazakii, Enterobacter spp., Lysinibacillus sphaericus, Pantoea spp., Pseudomonas spp. and Terribacillus saccharophilus are associated with T. Procumbens. Based on the results, we conclude that 24 different types of culturable BEs are associated with traditionally used medicinal plant, T. Procumbens, and require further study.
Parker, L.; Maman, S.; Pettifor, A.; Chalachala, J.L.; Edmonds, A.; Golin, C.E.; Moracco, K.; Behets, F.
2013-01-01
Effective HIV prevention programs for people living with HIV/AIDS (PLWH) are important to reduce new infections and to ensure PLWH remain healthy. This paper describes the systematic adaptation of a U.S.-developed Evidence Based Intervention (EBI) using the Centers for Disease Control and Prevention (CDC) Map of Adaption Process for use at a Pediatric Hospital in Kinshasa, Democratic Republic of the Congo (DRC). The adapted intervention, Supporting Youth and Motivating Positive Action or SYMPA, a six-session risk reduction intervention targeted for youth living with HIV/AIDS (YLWH) in Kinshasa was adapted from the Healthy Living Project and guided by the Social Action Theory. This paper describes the process of implementing the first four steps of the ADAPT framework (Assess, Select, Prepare, and Pilot). Our study has shown that an EBI developed and implemented in the U.S. can be adapted successfully for a different target population in a low-resource context through an iterative process following the CDC ADAPT framework. This process included reviewing existing literature, adapting and adding components, and focusing on increasing staff capacity. This paper provides a rare, detailed description of the adaptation process and may aid organizations seeking to adapt and implement HIV prevention EBIs in sub-Saharan Africa and beyond. PMID:23063699
Pendergast, Laura L; von der Embse, Nathaniel; Kilgus, Stephen P; Eklund, Katie R
2017-02-01
Evidence-based interventions (EBIs) have become a central component of school psychology research and practice, but EBIs are dependent upon the availability and use of evidence-based assessments (EBAs) with diverse student populations. Multi-group confirmatory factor analysis (MG-CFA) is an analytical tool that can be used to examine the validity and measurement equivalence/invariance of scores across diverse groups. The objective of this article is to provide a conceptual and procedural overview of categorical MG-CFA, as well as an illustrated example based on data from the Social and Academic Behavior Risk Screener (SABRS) - a tool designed for use in school-based interventions. This article serves as a non-technical primer on the topic of MG-CFA with ordinal (rating scale) data and does so through the framework of examining equivalence of measures used for EBIs within multi-tiered models - an understudied topic. To go along with the illustrated example, we have provided supplementary files that include sample data, Mplus input code, and an annotated guide for understanding the input code (http://dx.doi.org/10.1016/j.jsp.2016.11.002). Data needed to reproduce analyses in this article are available as supplemental materials (online only) in the Appendix of this article. Copyright © 2016 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Bender, Edward J.; Wood, Michael V.; Hart, Steve; Heim, Gerald B.; Torgerson, John A.
2004-10-01
Image intensifiers (I2) have gained wide acceptance throughout the Army as the premier nighttime mobility sensor for the individual soldier, with over 200,000 fielded systems. There is increasing need, however, for such a sensor with a video output, so that it can be utilized in remote vehicle platforms, and/or can be electronically fused with other sensors. The image-intensified television (I2TV), typically consisting of an image intensifier tube coupled via fiber optic to a solid-state imaging array, has been the primary solution to this need. I2TV platforms in vehicles, however, can generate high internal heat loads and must operate in high-temperature environments. Intensifier tube dark current, called "Equivalent Background Input" or "EBI", is not a significant factor at room temperature, but can seriously degrade image contrast and intra-scene dynamic range at such high temperatures. Cooling of the intensifier's photocathode is the only practical solution to this problem. The US Army RDECOM CERDEC Night Vision & Electronic Sensors Directorate (NVESD) and Ball Aerospace have collaborated in the reported effort to more rigorously characterize intensifier EBI versus temperature. NVESD performed non-imaging EBI measurements of Generation 2 and 3 tube modules over a large range of ambient temperature, while Ball performed an imaging evaluation of Generation 3 I2TVs over a similar temperature range. The findings and conclusions of this effort are presented.
E-MSD: an integrated data resource for bioinformatics
Velankar, S.; McNeil, P.; Mittard-Runte, V.; Suarez, A.; Barrell, D.; Apweiler, R.; Henrick, K.
2005-01-01
The Macromolecular Structure Database (MSD) group (http://www.ebi.ac.uk/msd/) continues to enhance the quality and consistency of macromolecular structure data in the worldwide Protein Data Bank (wwPDB) and to work towards the integration of various bioinformatics data resources. One of the major obstacles to the improved integration of structural databases such as MSD and sequence databases like UniProt is the absence of up to date and well-maintained mapping between corresponding entries. We have worked closely with the UniProt group at the EBI to clean up the taxonomy and sequence cross-reference information in the MSD and UniProt databases. This information is vital for the reliable integration of the sequence family databases such as Pfam and Interpro with the structure-oriented databases of SCOP and CATH. This information has been made available to the eFamily group (http://www.efamily.org.uk/) and now forms the basis of the regular interchange of information between the member databases (MSD, UniProt, Pfam, Interpro, SCOP and CATH). This exchange of annotation information has enriched the structural information in the MSD database with annotation from wider sequence-oriented resources. This work was carried out under the ‘Structure Integration with Function, Taxonomy and Sequences (SIFTS)’ initiative (http://www.ebi.ac.uk/msd-srv/docs/sifts) in the MSD group. PMID:15608192
Fletcher, Tim D; Walsh, Chistopher J; Bos, Darren; Nemes, Veronika; RossRakesh, Sharyn; Prosser, Toby; Hatt, Belinda; Birch, Rhiannon
2011-01-01
Urbanisation results in changes to runoff behaviour which, if not addressed, inevitably degrade receiving waters. To date, most stormwater management has focussed on the streetscape and public open space. Given that much of the catchment imperviousness is located on private land, we developed and tested a novel economic instrument (a uniform price auction) for encouraging allotment-scale stormwater retention. We evaluated bids using an integrated environmental benefit index (EBI), based on the ability of the proposed works to reduce runoff frequency, pollutant loads and to reduce potable water demand. The uniform price auction resulted in 1.4 ha of impervious areas being effectively 'disconnected' from the stormwater system. The EBI provided an objective and transparent method of comparing bids, which varied in the type of works proposed (e.g. rainwater tank, rain-garden), the cost and the resulting environmental benefit. Whilst the pilot auction was a success, the public subsidy of works undertaken was around 85%, meaning that property owners a relatively small private benefit in the works. Future auction rounds will be revised to (i) test an EBI which is more focussed on the protection of streams (assessing changes to runoff frequency, baseflow volumes and water quality) and (ii) provide an auction process which is simpler to understand, and provides greater practical support for landholders who wish to undertake works.
Ivanyushenkov, Y.; Harkay, K.; Borland, M.; ...
2017-10-03
Development of superconducting undulators continues at the Advanced Photon Source (APS). Two years after successful installation and commissioning of the first relatively short superconducting undulator “SCU0” in Sector 6 of the APS storage ring, the second 1.1-m long superconducting undulator “SCU1” was installed in Sector 1 of the APS. The device has been in user operation since its commissioning in May 2015. This paper describes the magnetic and cryogenic design of the SCU1 together with the results of stand-alone cold tests. The SCU1’s magnetic and cryogenic performance as well as its operating experience in the APS storage ring are alsomore » presented.« less
Coupling control and optimization at the Canadian Light Source
NASA Astrophysics Data System (ADS)
Wurtz, W. A.
2018-06-01
We present a detailed study using the skew quadrupoles in the Canadian Light Source storage ring lattice to control the parameters of a coupled lattice. We calculate the six-dimensional beam envelop matrix and use it to produce a variety of objective functions for optimization using the Multi-Objective Particle Swarm Optimization (MOPSO) algorithm. MOPSO produces a number of skew quadrupole configurations that we apply to the storage ring. We use the X-ray synchrotron radiation diagnostic beamline to image the beam and we make measurements of the vertical dispersion and beam lifetime. We observe satisfactory agreement between the measurements and simulations. These methods can be used to adjust phase space coupling in a rational way and have applications to fine-tuning the vertical emittance and Touschek lifetime and measuring the gas scattering lifetime.
The development of enabling technologies for producing active interrogation beams.
Kwan, Thomas J T; Morgado, Richard E; Wang, Tai-Sen F; Vodolaga, B; Terekhin, V; Onischenko, L M; Vorozhtsov, S B; Samsonov, E V; Vorozhtsov, A S; Alenitsky, Yu G; Perpelkin, E E; Glazov, A A; Novikov, D L; Parkhomchuk, V; Reva, V; Vostrikov, V; Mashinin, V A; Fedotov, S N; Minayev, S A
2010-10-01
A U.S./Russian collaboration of accelerator scientists was directed to the development of high averaged-current (∼1 mA) and high-quality (emittance ∼15 πmm mrad; energy spread ∼0.1%) 1.75 MeV proton beams to produce active interrogation beams that could be applied to counterterrorism. Several accelerator technologies were investigated. These included an electrostatic tandem accelerator of novel design, a compact cyclotron, and a storage ring with energy compensation and electron cooling. Production targets capable of withstanding the beam power levels were designed, fabricated, and tested. The cyclotron/storage-ring system was theoretically studied and computationally designed, and the electrostatic vacuum tandem accelerator at BINP was demonstrated for its potential in active interrogation of explosives and special nuclear materials.
Schmitt, Thorsten; de Groot, Frank M. F.; Rubensson, Jan-Erik
2014-01-01
The spectroscopic technique of resonant inelastic X-ray scattering (RIXS) will particularly profit from immensely improved brilliance of diffraction-limited storage rings (DLSRs). In RIXS one measures the intensities of excitations as a function of energy and momentum transfer. DLSRs will allow for pushing the achievable energy resolution, signal intensity and the sampled spot size to new limits. With RIXS one nowadays probes a broad range of electronic systems reaching from simple molecules to complex materials displaying phenomena like peculiar magnetism, two-dimensional electron gases, superconductivity, photovoltaic energy conversion and heterogeneous catalysis. In this article the types of improved RIXS studies that will become possible with X-ray beams from DLSRs are envisioned. PMID:25177995
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ivanyushenkov, Y.; Harkay, K.; Borland, M.
Development of superconducting undulators continues at the Advanced Photon Source (APS). Two years after successful installation and commissioning of the first relatively short superconducting undulator “SCU0” in Sector 6 of the APS storage ring, the second 1.1-m long superconducting undulator “SCU1” was installed in Sector 1 of the APS. The device has been in user operation since its commissioning in May 2015. This paper describes the magnetic and cryogenic design of the SCU1 together with the results of stand-alone cold tests. The SCU1’s magnetic and cryogenic performance as well as its operating experience in the APS storage ring are alsomore » presented.« less
Time domain analysis of coherent terahertz synchrotron radiation
NASA Astrophysics Data System (ADS)
Hübers, H.-W.; Semenov, A.; Holldack, K.; Schade, U.; Wüstefeld, G.; Gol'tsman, G.
2005-10-01
The time structure of coherent terahertz synchrotron radiation at the electron storage ring of the Berliner Elektronensynchrotron und Speicherring Gesellschaft has been analyzed with a fast superconducting hot-electron bolometer. The emission from a single bunch of electrons was found to last ˜1500ps at frequencies around 0.4THz, which is much longer than the length of an electron bunch in the time domain (˜5ps). It is suggested that this is caused by multiple reflections at the walls of the beam line. The quadratic increase of the power with the number of electrons in the bunch as predicted for coherent synchrotron radiation and the transition from stable to bursting radiation were determined from a single storage ring fill pattern of bunches with different populations.
Design of barrier bucket kicker control system
NASA Astrophysics Data System (ADS)
Ni, Fa-Fu; Wang, Yan-Yu; Yin, Jun; Zhou, De-Tai; Shen, Guo-Dong; Zheng, Yang-De.; Zhang, Jian-Chuan; Yin, Jia; Bai, Xiao; Ma, Xiao-Li
2018-05-01
The Heavy-Ion Research Facility in Lanzhou (HIRFL) contains two synchrotrons: the main cooler storage ring (CSRm) and the experimental cooler storage ring (CSRe). Beams are extracted from CSRm, and injected into CSRe. To apply the Barrier Bucket (BB) method on the CSRe beam accumulation, a new BB technology based kicker control system was designed and implemented. The controller of the system is implemented using an Advanced Reduced Instruction Set Computer (RISC) Machine (ARM) chip and a field-programmable gate array (FPGA) chip. Within the architecture, ARM is responsible for data presetting and floating number arithmetic processing. The FPGA computes the RF phase point of the two rings and offers more accurate control of the time delay. An online preliminary experiment on HIRFL was also designed to verify the functionalities of the control system. The result shows that the reference trigger point of two different sinusoidal RF signals for an arbitrary phase point was acquired with a matched phase error below 1° (approximately 2.1 ns), and the step delay time better than 2 ns were realized.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plogmaker, Stefan; Johansson, Erik M. J.; Rensmo, Haakan
A novel light chopper system for fast timing experiments in the vacuum-ultraviolet (VUV) and x-ray spectral region has been developed. It can be phase-locked and synchronized with a synchrotron radiation storage ring, accommodating repetition rates in the range of {approx}8 to {approx}120 kHz by choosing different sets of apertures and subharmonics of the ring frequency (MHz range). Also the opening time of the system can be varied from some nanoseconds to several microseconds to meet the needs of a broad range of applications. Adjusting these parameters, the device can be used either for the generation of single light pulses ormore » pulse packages from a microwave driven, continuous He gas discharge lamp or from storage rings which are otherwise often considered as quasi-continuous light sources. This chopper can be utilized for many different kinds of experiments enabling, for example, unambiguous time-of-flight (TOF) multi-electron coincidence studies of atoms and molecules excited by a single light pulse as well as time-resolved visible laser pump x-ray probe electron spectroscopy of condensed matter in the valence and core level region.« less
Fabrication and test of model superconducting inflector for g-2 at FNAL
Krave, Steven; Kashikhin, Vladimir S.; Strauss, Thomas
2017-03-01
The new FNAL g-2 experiment is based on the muon storage ring previously used at BNL. The 1.45 T dipole magnetic field in the storage ring is required to have very high (1 ppm) homogeneity. The muon beam injected into the ring must be transported through the magnet yoke and the main superconducting coil cryostat with minimal distortions. The old inflector magnet shielded the main dipole fringe field inside the muon transport beam pipe, with an outer NbTi superconducting screen, and did not disturb the field in the area of circulating beam. Nevertheless, this magnet had coils with closed endsmore » in which a large fraction of muon beam particles were lost. A new magnet is envisioned utilizing the same cross section as the original with open ends for improved beam transport. A model magnet has been wound utilizing 3d printed parts to verify the magnetic behavior of the magnet at room temperature and validate winding of the complicated geometry required for the magnet ends. Finally, room temperature magnetic measurements have been performed and confirm the magnetic design« less
Electron molecular ion recombination: product excitation and fragmentation.
Adams, Nigel G; Poterya, Viktoriya; Babcock, Lucia M
2006-01-01
Electron-ion dissociative recombination is an important ionization loss process in any ionized gas containing molecular ions. This includes the interstellar medium, circumstellar shells, cometary comae, planetary ionospheres, fusion plasma boundaries, combustion flames, laser plasmas and chemical deposition and etching plasmas. In addition to controlling the ionization density, the process generates many radical species, which can contribute to a parallel neutral chemistry. Techniques used to obtain rate data and product information (flowing afterglows and storage rings) are discussed and recent data are reviewed including diatomic to polyatomic ions and cluster ions. The data are divided into rate coefficients and cross sections, including their temperature/energy dependencies, and quantitative identification of neutral reaction products. The latter involve both ground and electronically excited states and including vibrational excitation. The data from the different techniques are compared and trends in the data are examined. The reactions are considered in terms of the basic mechanisms (direct and indirect processes including tunneling) and recent theoretical developments are discussed. Finally, new techniques are mentioned (for product identification; electrostatic storage rings, including single and double rings; Coulomb explosion) and new ways forward are suggested.
9975 Shipping package component long-term degradation rates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W. L.
Special nuclear materials are being stored in the K-Area Complex using 3013 containers that are held within Model 9975 shipping packages. The service life for these packages in storage was recently increased from 15 to 20 years, since some of these packages have been stored for nearly 15 years. A strategy is also being developed whereby such storage might be extended beyond 20 years. This strategy is based on recent calculations that support acceptable 9975 package performance for 20 years with internal heat loads up to 19 watts, and identifies a lower heat load limit for which the package componentsmore » should degrade at half the bounding rate or less, thus doubling the effective storage life for these lower wattage packages. The components of the 9975 package that are sensitive to aging under storage conditions are the fiberboard overpack and the O-ring seals, although some degradation of the lead shield and outer drum are also possible. This report summarizes degradation rates applicable to lower heat load storage conditions. In particular, the O-ring seals should provide leak-tight performance for more than 40 years in packages for which their maximum temperature is ≤135 °F. Similarly, the fiberboard should remain acceptable in performance of its required safety functions for up to 40 years in packages with a maximum fiberboard temperature ≤125 °F.« less
Hawaii Energy and Environmental Technologies Initiative 2010 (HEET10)
2016-09-30
illustrated how local battery storage support of the lOMW Hawi wind farm can cause grid-wide issues. However, it was found that battery cycling can...capabilities pertaining to three different ex situ diagnostics were acquired and used under HEETlO. Focus was given to the catalyst (rotating ring ...cell. These capabilities are illustrated in Figure 9 1.1.1. Figure 1.1.1: (left) rotating ring /disc electrode; (middle) membrane conductivity cell
Using equivalence-based instruction to teach piano skills to college students.
Griffith, Kristin R; Ramos, Amber L; Hill, Kelli E; Miguel, Caio F
2018-04-01
The purpose of the current study was to evaluate the effects of equivalence-based instruction (EBI) on the emergence of basic music reading and piano playing skills. Six female college students learned to identify three musical chord notations given their respective dictated names. Participants also learned to play chords on the piano following the dictated name of the chord, and to play the chords to a song on a keyboard. Results are consistent with past research, in that stimuli became substitutable for each other and acquired a common behavioral function. Data suggest that EBI was an effective and efficient procedure to teach adults to read musical notation, as well as play chords and a song on a piano keyboard. © 2018 Society for the Experimental Analysis of Behavior.
Design study of primary ion provider for relativistic heavy ion collider electron beam ion source.
Kondo, K; Kanesue, T; Tamura, J; Okamura, M
2010-02-01
Brookhaven National Laboratory has developed the new preinjector system, electron beam ion source (EBIS) for relativistic heavy ion collider (RHIC) and National Aeronautics and Space Administration Space Radiation Laboratory. Design of primary ion provider is an essential problem since it is required to supply beams with different ion species to multiple users simultaneously. The laser ion source with a defocused laser can provide a low charge state and low emittance ion beam, and is a candidate for the primary ion source for RHIC-EBIS. We show a suitable design with appropriate drift length and solenoid, which helps to keep sufficient total charge number with longer pulse length. The whole design of primary ion source, as well as optics arrangement, solid targets configuration and heating about target, is presented.
The European Bioinformatics Institute’s data resources 2014
Brooksbank, Catherine; Bergman, Mary Todd; Apweiler, Rolf; Birney, Ewan; Thornton, Janet
2014-01-01
Molecular Biology has been at the heart of the ‘big data’ revolution from its very beginning, and the need for access to biological data is a common thread running from the 1965 publication of Dayhoff’s ‘Atlas of Protein Sequence and Structure’ through the Human Genome Project in the late 1990s and early 2000s to today’s population-scale sequencing initiatives. The European Bioinformatics Institute (EMBL-EBI; http://www.ebi.ac.uk) is one of three organizations worldwide that provides free access to comprehensive, integrated molecular data sets. Here, we summarize the principles underpinning the development of these public resources and provide an overview of EMBL-EBI’s database collection to complement the reviews of individual databases provided elsewhere in this issue. PMID:24271396
A FODO racetrack ring for nuSTORM: design and optimization
Liu, A.; Bross, A.; Neuffer, D.
2017-07-17
Here, the goal of nuSTORM is to provide well-defined neutrino beams for precise measurements of neutrino cross-sections and oscillations. The nuSTORM decay ring is a compact racetrack storage ring with a circumference of ~ 480 m that incorporates large aperture (60 cm diameter) magnets. There are many challenges in the design. In order to incorporate the Orbit Combination section (OCS), used for injecting the pion beam into the ring, a dispersion suppressor is needed adjacent to the OCS . Concurrently, in order to maximize the number of useful muon decays, strong bending dipoles are needed in the arcs to minimize themore » arc length. These dipoles create strong chromatic effects, which need to be corrected by nonlinear sextupole elements in the ring. In this paper, a FODO racetrack ring design and its optimization using sextupolar fields via both a Genetic Algorithm (GA) and a Simulated Annealing (SA) algorithm will be discussed.« less
NASA Astrophysics Data System (ADS)
Tatchyn, Roman
1997-05-01
In recent years studies have been initiated on a new class of multipole field generators consisting of cuboid planar permanent magnet (PM) pieces arranged in bi-planar arrays of 2-fold rotational symmetry(R. Tatchyn, "Planar Permanent Magnet Multipoles: for Particle Accelerator and Storage Ring Applications ," IEEE Trans. Mag. 30, 5050(1994).)(T. Cremer, R. Tatchyn, "Planar Permanent Magnet Multipoles: Measurements and Configurations," in Proceedings of the 1995 Particle Accelerator Conference, IEEE Catalog No. 95CH35843, paper FAQ-20.). These structures, first introduced for Free Electron Laser (FEL) applications(R. Tatchyn, "Selected applications of planar permanent magnet multipoles in FEL insertion device design," NIM A341, 449(1994).), are based on reducing the rotational symmetry of conventional N-pole field generators from N-fold to 2-fold. One consequence of this reduction is a large higher-multipole content in a planar PM multipole's field at distances relatively close to the structure's axis, making it generally unsuitable for applications requiring a large high-quality field aperture. In this paper we outline an economical field-cancellation algorithm that can substantially decrease the harmonic content of a planar PM's field without breaking its biplanar geometry or 2-fold rotational symmetry. This will enable planar PM multipoles to be employed in a broader range of applications than heretofore possible, in particular as distributed focusing elements installed in insertion device gaps on synchrotron storage rings. This accomplishment is expected to remove the conventional restriction of an insertion device's length to the scale of the local focusing beta, enabling short-period, small-gap undulators to be installed and operated as high-brightness sources on lower-energy storage rings(R. Tatchyn, P. Csonka, A. Toor, "Perspectives on micropole undulators in synchrotron radiation technology," Rev. Sci. Instrum. 60(7), 1796(1989).). Operation as ordinary focusing elements in storage ring magnetic lattices, as well as the performance of other high-quality multipole applications, should also becomes possible with the realization of the proposed structures.
ACCELERATORS: RF system design and measurement of HIRF-CSRe
NASA Astrophysics Data System (ADS)
Xu, Zhe; Zhao, Hong-Wei; Wang, Chun-Xiao; Xia, Jia-Wen; Zhan, Wen-Long; Bian, Zhi-Bin
2009-05-01
An RF system for the CSRe (cooling storage experimental ring) is designed and manufactured domestically. The present paper mainly describes the RF system design in five main sections: ferrite ring, RF cavity, RF generator, low level system and cavity cooling. The cavity is based on a type of coaxial resonator which is shorted at the end with one gap and loaded with domestic ferrite rings. The RF generator is designed in the push-pull mode and the low level control system is based on a DSP+FGPA+DDS+USB interface and has three feedback loops. Finally we give the results of the measurement on our system.
Wang, Yonghua; Xue, Chenyang; Zhang, Zengxing; Zheng, Hua; Zhang, Wendong; Yan, Shubin
2016-12-12
The analogue of electromagnetically induced transparency in optical ways has shown great potential in optical delay and quantum-information technology due to its flexible design and easy implementation. The chief drawback for these devices is the bad tunability. Here we demonstrate a tunable optical transparency system formed by graphene-silicon microrings which could control the transparent window by electro-optical means. The device consists of cascaded coupled ring resonators and a graphene/graphene capacitor which integrated on one of the rings. By tuning the Fermi level of the graphene sheets, we can modulate the round-trip ring loss so that the transparency window can be dynamically tuned. The results provide a new method for the manipulation and transmission of light in highly integrated optical circuits and quantum information storage devices.
DEVELOPMENT OF TITANIUM NITRIDE COATING FOR SNS RING VACUUM CHAMBERS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
HE,P.; HSEUH,H.C.; MAPES,M.
2001-06-18
The inner surface of the ring vacuum chambers of the US Spallation Neutron Source (SNS) will be coated with {approximately}100 nm of Titanium Nitride (TiN). This is to minimize the secondary electron yield (SEY) from the chamber wall, and thus avoid the so-called e-p instability caused by electron multipacting as observed in a few high-intensity proton storage rings. Both DC sputtering and DC-magnetron sputtering were conducted in a test chamber of relevant geometry to SNS ring vacuum chambers. Auger Electron Spectroscopy (AES) and Rutherford Back Scattering (RBS) were used to analyze the coatings for thickness, stoichiometry and impurity. Excellent resultsmore » were obtained with magnetron sputtering. The development of the parameters for the coating process and the surface analysis results are presented.« less
Simulation of emittance dilution in electron storage ring from Compton backscattering
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blumberg, L.N.; Blum, E.
1993-07-01
A Monte-Carlo simulation of Compton backscattered {kappa}{sub L}=3.2-{mu}m photons from an IR-FEL on 75-MeV electrons in a storage ring yields an RMS electron energy spread of {Delta}{sub E}=11.9-keV for a sample of 10{sup 7} single scattering events. Electrons are sampled from a beam of natural energy spread {sigma}{sub E} = 5.6-keV and damped transverse angle spreads {sigma}{sub x}{prime}, = .041-mrad and {sigma}{sub y}{prime} = .052-mrad (100%) coupling, scaled from the 200-MeV BNL XLS compact storage ring. The Compton-scattered X-Rays are generated from an integral of the CM Klein-Nishina cross-section transformed to the lab. A tracking calculation has also been performedmore » in 6-dimensional phase space. Initial electron coordinates are selected randomly from a Gaussian distribution of RMS spreads {sigma}{sub xo}=.102-mm, {sigma}{sub x{prime}o}=.041-mrad, {sigma}{sub yo}=.018-mm, {sigma}{sub y{prime}o}=.052-mrad, {sigma}{sub {phi}o}=22-mrad and {sigma}{sub Eo}=6-keV. A sample of 10000 electrons were each following for 40000 turns around the ring through an RF cavity of f{sub rf}=211.54-MHz and peak voltage V{sub m}=300-keV. Preliminary results indicate that the resulting energy distribution is quite broad with an RMS width of {Delta}{sub E} = 124-keV. The transverse widths are only slightly increased from their original values, i.e. {Delta}{sub x} = .106-mm and {Delta}{sub x}{prime}=.043 mrad. The scaled energy spread of {Delta}{sub E} {approximately} 360-keV for {approximately} 350,000 turns desired in a 10-msec X-Ray angiography exposure is well within the RF bucket used here; even V{sub m} < 50-kV is adequate. Further, the electron energy spread adds a negligible RMS X-Ray energy spread of {Delta}{sub Ex}=.32-keV. The electron energy damping time of {tau}{sub E}=379-msec at 75-MeV in an XLS-type ring allows for damping this induced spread and top-off of the ring between heart cycles.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rovirosa, Angeles, E-mail: rovirosa@clinic.ub.es; Ascaso, Carlos; Sanchez-Reyes, Alberto
2011-10-01
Purpose: To evaluate the results of high-dose-rate brachytherapy (HDRBT) using a schedule of three or four fractions per week, when possible, in 89 patients on local control and toxicity in postoperative treatment of endometrial carcinoma. The effect of the overall HDRBT treatment time (OTT) on toxicity was also evaluated. Patients and Methods: Federation Internationale de Gynecologie Obstetrique Stage: 24 IB, 45 IC, 4 IIA, 6 IIB, 4 IIIA, 2 IIIB, and 4 IIIC. Radiotherapy: Group 1-67 of 89 patients received external beam irradiation (EBI; 44-50 Gy) plus HDRBT (3 fractions of 4-6 Gy); Group 2-22 of 89 patients received HDRBTmore » alone (6 fractions of 4-5 Gy). OTT: Group 1-HDRBT was completed in a median of 5 days in 32 patients and in >5 days in 35; Group 2-HDRBT was completed in <15 days in 11 patients and in {>=}16 days in 11. Toxicity was evaluated using Radiation Therapy Oncology Group scores and the bioequivalent dose (BED) study was performed in vaginal mucosa surface. Statistics included Student's t test, chi-square test, and receiving operator curves. Results: With a mean follow-up of 31 months (range, 6-70), 1 of 89 patients had vaginal relapse. Early toxicity appeared in 8 of 89 (9%) patients and was resolved. Late toxicity appeared in 13/89 (14%): vaginal nine Grade 1, three Grade 2, one Grade 4; bladder two Grade 2; rectal three Grade 1, one Grade 2. No differences were found in relation to OTT in Groups 1 and 2. Mean BED was 88.48 Gy in Group 1 and 165.28 Gy in Group 2. Cases with Grade 2 late vaginal toxicity received >75 Gy after EBI and >165 Gy in Group 2. Conclusions: Three fractions of 4-5 Gy in 3-5 days after EBI or 6 fractions in <15 days in patients receiving HDRBT alone was a safe treatment in relation to toxicity and local control. Vaginal surface BED less than 75 Gy after EBI and less than 160 Gy in HDRBT alone may be safe to avoid G2 toxicity.« less
Principles for timing at spallation neutron sources based on developments at LANSCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, R. O.; Merl, R. B.; Rose, C. R.
2001-01-01
Due to AC-power-grid frequency fluctuations, the designers for accelerator-based spallation-neutron facilities have worked to optimize the conflicting demands of accelerator and neutron chopper performance. For the first time, we are able to quantitatively access the tradeoffs between these two constraints and design or upgrade a facility to optimize total system performance using powerful new simulation techniques. We have modeled timing systems that integrate chopper controllers and chopper hardware and built new systems. Thus, at LANSCE, we now operate multiple chopper systems and the accelerator as simple slaves to a single master-timing-reference generator. Based on this experience we recommend that spallationmore » neutron sources adhere to three principles. First, timing for pulsed sources should be planned starting with extraction at a fixed phase and working backwards toward the leading edge of the beam pulse. Second, accelerator triggers and storage ring extraction commands from neutron choppers offer only marginal benefits to accelerator-based spallation sources. Third, the storage-ring RF should be phase synchronized with neutron choppers to provide extraction without the one orbit timing uncertainty.« less
MetaboLights: towards a new COSMOS of metabolomics data management.
Steinbeck, Christoph; Conesa, Pablo; Haug, Kenneth; Mahendraker, Tejasvi; Williams, Mark; Maguire, Eamonn; Rocca-Serra, Philippe; Sansone, Susanna-Assunta; Salek, Reza M; Griffin, Julian L
2012-10-01
Exciting funding initiatives are emerging in Europe and the US for metabolomics data production, storage, dissemination and analysis. This is based on a rich ecosystem of resources around the world, which has been build during the past ten years, including but not limited to resources such as MassBank in Japan and the Human Metabolome Database in Canada. Now, the European Bioinformatics Institute has launched MetaboLights, a database for metabolomics experiments and the associated metadata (http://www.ebi.ac.uk/metabolights). It is the first comprehensive, cross-species, cross-platform metabolomics database maintained by one of the major open access data providers in molecular biology. In October, the European COSMOS consortium will start its work on Metabolomics data standardization, publication and dissemination workflows. The NIH in the US is establishing 6-8 metabolomics services cores as well as a national metabolomics repository. This communication reports about MetaboLights as a new resource for Metabolomics research, summarises the related developments and outlines how they may consolidate the knowledge management in this third large omics field next to proteomics and genomics.
Space charge tune shift, fast resonance traversal, and current limits in circular accelerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rees, G.H.
1996-06-01
Space charge tune shifts, fast resonance traversals, and current limits are important design issues for low energy, high power circular accelerators. Areas of interest are accumulator rings and fast cycling synchrotrons, and typical applications are for pulsed spallation neutron sources, heavy ion fusion storage ring drivers, and booster injectors for high energy proton and ion facilities. Aspects of the three topics are discussed in the paper. {copyright} {ital 1996 American Institute of Physics.}
NASA Astrophysics Data System (ADS)
Zhang, Yichi; Wang, Ping; Li, Liang; Chen, Zhimin; He, Chunying; Wu, Yiqun
Preparation of recording materials with high two-photon absorption activities is one of the important issues to superhigh- density two-photon absorption (TPA) three-dimensional (3D) optical data storage. In this paper, three new carbazole derivatives containing nitrogen heterocyclic ring with symmetric and asymmetric structures are prepared using ethylene as the π bridge between the carbazole unit and nitrogen heterocyclic ring, namely, 9-butyl-3-(2-(1,8- naphthyridin)vinyl)-carbazole (material 1), 9-butyl-3,6-bis(2-(1,8-naphthyl)vinyl)-carbazole (material 2) and 9-butyl-3,6- bis(2-(quinolin)vinyl)-carbazole (material 3). Their one photon properties including linear absorption spectra, fluorescence emission spectra, and fluorescence quantum yields are studied. The fluorescence excited by 120 fs pulse at 800 nm Ti: sapphire laser operating at 1 kHz repetition rate with different incident powers of 9-butyl-3-(2-(quinolin) vinyl)-carbazole (material 3) was investigated, and two-photon absorption cross-sections has been obtained. It is shown that material 3 containing quinoline rings as electron acceptor with symmetric structure exhibit high two-photon absorption activity. The result implies that material 3 (9-butyl-3-(2-(quinolin) vinyl)-carbazole) is a good candidate as a promising recording material for super-high-density two-photon absorption (TPA) three-dimensional (3D) optical data storage. The influence of chemical structure of the materials on the optical properties is discussed.
FIRST BEAM TESTS OF THE APS MBA UPGRADE ORBIT FEEDBACK CONTROLLER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sereno, N. S.; Arnold, N.; Brill, A.
The new orbit feedback system required for the APS multi-bend acromat (MBA) ring must meet challenging beam stability requirements. The AC stability requirement is to correct rms beam motion to 10 % the rms beam size at the insertion device source points from 0.01 to 1000 Hz. The vertical plane represents the biggest challenge for AC stability which is required to be 400 nm rms for a 4 micron vertical beam size. In addition long term drift over a period of 7 days is required to be 1 micron or less at insertion de- vice BPMs and 2 microns formore » arc bpms. We present test re- sults of theMBA prototype orbit feedback controller (FBC) in the APS storage ring. In this test, four insertion device BPMs were configured to send data to the FBC for process- ing into four fast corrector setpoints. The configuration of four bpms and four fast correctors creates a 4-bump and the configuration of fast correctors is similar to what will be implemented in the MBA ring. We report on performance benefits of increasing the sampling rate by a factor of 15 to 22.6 kHz over the existing APS orbit feedback system, lim- itations due to existing storage ring hardware and extrapo- lation to theMBA orbit feedback design. FBC architecture, signal flow and processing design will also be discussed.« less
Calculations of the conditions for bunch leakage in the Los Alamos proton storage ring
NASA Astrophysics Data System (ADS)
Neuffer, D.; Ohmori, C.
1994-04-01
Observations are consistent with the possibility of an "ep" instability in the Los Alamos Proton Storage Ring (PSR) with both bunched and unbunched beam. The instability requires electrons to be trapped within the beam, and calculations have shown that such trapping requires leakage of beam into the interbunch gap. Observationally, leakage of beam into the gap appears necessary for the onset of the instability. In this paper we present results of studies of the longitudinal beam dynamics at PSR parameters. The studies indicate that the combined effects of the rf buncher, longitudinal space charge, and injection mismatch are sufficient to cause the observed bunch leakage. Simulation results are presented and compared with PSR observations. Variations of PSR performance parameters are considered, and methods of improving bunch confinement are suggested and studied.
STORAGE RING CROSS SECTION MEASUREMENTS FOR ELECTRON IMPACT IONIZATION OF Fe{sup 7+}
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hahn, M.; Novotný, O.; Savin, D. W.
2015-11-01
We have measured electron impact ionization for Fe{sup 7+} from the ionization threshold up to 1200 eV. The measurements were performed using the TSR heavy ion storage ring. The ions were stored long enough prior to measurements to remove most metastables, resulting in a beam of 94% ground-level ions. Comparing with the previously recommended atomic data, we find that the Arnaud and Raymond cross section is up to about 40% larger than our measurement, with the largest discrepancies below about 400 eV. The cross section of Dere agrees to within 10%, which is about the magnitude of the experimental uncertainties.more » The remaining discrepancies between our measurement and the Dere calculations are likely due to shortcomings in the theoretical treatment of the excitation-autoionization contribution.« less
Installation of a second superconducting wiggler at SAGA-LS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaneyasu, T., E-mail: kaneyasu@saga-ls.jp; Takabayashi, Y.; Iwasaki, Y.
The SAGA Light Source is a synchrotron radiation facility consisting of a 255 MeV injector linac and a 1.4 GeV storage ring with a circumference of 75.6 m. A superconducting wiggler (SCW) with a peak magnetic field of 4 T has been routinely operating for generating hard X-rays since its installation in 2010. In light of this success, it was decided to install a second SCW as a part of the beamline construction by Sumitomo Electric Industries. To achieve this, machine modifications including installation of a new magnet power supply, improvement of the magnet control system, and replacement of themore » vacuum chambers in the storage ring were carried out. Along with beamline construction, installation and commissioning of the second SCW are scheduled to take place in 2015.« less
NASA Astrophysics Data System (ADS)
Pop, Nicolina; Iacob, Felix; Mezei, Zsolt; Motapon, Ousmanou; Niyonzima, Sebastien; Schneider, Ioan
2017-10-01
Dissociative recombination, ro-vibrational excitation and dissociative excitation of molecular cations with electrons are major elementary process in the kinetics and in the energy balance of astrophysically-relevant ionized media (supernovae, interstellar molecular clouds, planetary ionospheres, early Universe), in edge fusion and in many other cold media of technological interest. For the fusion plasma edge, extensive cross sections and rate coefficients have been produced for reactions induced on HD+, H2+ and BeD+ using the Multichannel Quantum Defect Theory (MQDT). Our calculations resulted in good agreement with the CRYRING (Stockholm) and TSR (Heidelberg) magnetic storage ring results, and our approach is permanently improved in order to face the new generation of electrostatic storage rings, as CSR (Heidelberg) and DESIREE (Stockholm). Member of APS Reciprocal Society: European Physics Society.
Non-exponential decoherence of radio-frequency resonance rotation of spin in storage rings
NASA Astrophysics Data System (ADS)
Saleev, A.; Nikolaev, N. N.; Rathmann, F.; Hinder, F.; Pretz, J.; Rosenthal, M.
2017-08-01
Precision experiments, such as the search for electric dipole moments of charged particles using radio-frequency spin rotators in storage rings, demand for maintaining the exact spin resonance condition for several thousand seconds. Synchrotron oscillations in the stored beam modulate the spin tune of off-central particles, moving it off the perfect resonance condition set for central particles on the reference orbit. Here, we report an analytic description of how synchrotron oscillations lead to non-exponential decoherence of the radio-frequency resonance driven up-down spin rotations. This non-exponential decoherence is shown to be accompanied by a nontrivial walk of the spin phase. We also comment on sensitivity of the decoherence rate to the harmonics of the radio-frequency spin rotator and a possibility to check predictions of decoherence-free magic energies.
NASA Astrophysics Data System (ADS)
Wu, W. Z.; Kim, Y.; Li, J. Y.; Teytelman, D.; Busch, M.; Wang, P.; Swift, G.; Park, I. S.; Ko, I. S.; Wu, Y. K.
2011-03-01
Electron beam coupled-bunch instabilities can limit and degrade the performance of storage ring based light sources. A longitudinal feedback system has been developed for the Duke storage ring to suppress multi-bunch beam instabilities which prevent stable, high-current operation of the storage ring based free-electron lasers (FELs) and an FEL driven Compton gamma source, the high intensity gamma-ray source (HIGS) at Duke University. In this work, we report the development of a state-of-the-art second generation longitudinal feedback system which employs a field programmable gate array (FPGA) based processor, and a broadband, high shunt-impedance kicker cavity. With two inputs and two outputs, the kicker cavity was designed with a resonant frequency of 937 MHz, a bandwidth of 97 MHz, and a shunt impedance of 1530 Ω. We also developed an S-matrix based technique to fully characterize the performance of the kicker cavity in the cold test. This longitudinal feedback system has been commissioned and optimized to stabilize high-current electron beams with a wide range of electron beam energies (250 MeV to 1.15 GeV) and a number of electron beam bunch modes, including the single-bunch mode and all possible symmetric bunch modes. This feedback system has become a critical instrument to ensure stable, high-flux operation of HIGS to produce nearly monochromatic, highly polarized Compton gamma-ray beams.
Bassi, G.; Blednykh, A.; Cheng, W.; ...
2015-12-11
We present the NSLS-II storage ring that is designed to operate with superconducting RF-cavities with the aim to store an average current of 500 mA distributed in 1080 bunches, with a gap in the uniform filling for ion clearing. At the early stage of the commissioning (phase 1), characterized by a bare lattice without damping wigglers and without Landau cavities, a normal conducting 7-cell PETRA-III RF-cavity structure has been installed with the goal to store an average current of 25 mA. In this paper we discuss our analysis of coupled-bunch instabilities driven by the Higher Order Modes (HOMs) of themore » 7-cell PETRA-III RF-cavity. As a cure of the instabilities, we apply a well-known scheme based on a proper detuning of the HOMs frequencies based upon cavity temperature change, and the use of the beneficial effect of the slow head–tail damping at positive chromaticity to increase the transverse coupled-bunch instability thresholds. In addition, we discuss measurements of coupled-bunch instabilities observed during the phase 1 commissioning of the NSLS-II storage ring. In our analysis we rely, in the longitudinal case, on the theory of coupled-bunch instability for uniform fillings, while in the transverse case we complement our studies with numerical simulations with OASIS, a novel parallel particle tracking code for self-consistent simulations of collective effects driven by short and long-range wakefields.« less
NINTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W.
2014-08-06
A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determinemore » if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The earliest 300 °F GLT O-ring fixture failure was observed at 34 months. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 72 - 96 months, which bounds O-ring temperatures anticipated during storage in K-Area Complex (KAC). Based on expectations that the 200 ºF fixtures will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures, thus providing additional time to failure data. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 54 - 57 months. No additional O-ring failures have been observed since the last interim report was issued. Aging and periodic leak testing will continue for the remaining PCV fixtures. Additional irradiation of several fixtures is recommended to maintain a balance between thermal and radiation exposures similar to that experienced in storage, and to show the degree of consistency of radiation response between GLT and GLT-S O-rings.« less
Generation of magneto-immersed electron beams
NASA Astrophysics Data System (ADS)
Pikin, A.; Raparia, D.
2018-05-01
There are many applications of electron beams in accelerator facilities: for electron coolers, electron lenses, and electron beam ion sources (EBIS) to mention a few. Most of these applications require magnetic compression of the electron beam to reduce the beam radius with the goal of either matching the circulating ion beam (electron lenses and electron coolers) or increasing the ionization capability for the production of highly charged ions (EBIS). The magnetic compression of the electron beam comes at a cost of increasing share of the transverse component of energy and therefore increased angles of the electron trajectories to the longitudinal axis. Considering the effect of the magnetic mirror, it is highly desirable to produce a laminar electron beam in the electron gun. The analysis of electron guns with different configurations is given in this paper with emphasis on generating laminar electron beams.
Ion Sources, Preinjectors and the Road to EBIS (459th Brookhaven Lecture)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alessi, James
2010-07-21
To meet the requirements of the scientific programs of the Relativistic Heavy Ion Collider and the NASA Space Radiation Lab, BNL's Collider-Accelerator Department needs a variety of ion sources. Although these sources are a relatively small and inexpensive part of an accelerator, they can have a big impact on the machine's overall performance. For the 459th Brookhaven Lecture, James Alessi will describe C-AD's long history of developing state-of-the-art ion sources for its accelerators, and its current process for source and pre-injector development. He will follow up with a discussion of the features and development status of EBIS, which, as themore » newest source and preinjector, is in the final stages of commissioning at the end of a five-year construction project.« less
Chemical Entity Recognition and Resolution to ChEBI
Grego, Tiago; Pesquita, Catia; Bastos, Hugo P.; Couto, Francisco M.
2012-01-01
Chemical entities are ubiquitous through the biomedical literature and the development of text-mining systems that can efficiently identify those entities are required. Due to the lack of available corpora and data resources, the community has focused its efforts in the development of gene and protein named entity recognition systems, but with the release of ChEBI and the availability of an annotated corpus, this task can be addressed. We developed a machine-learning-based method for chemical entity recognition and a lexical-similarity-based method for chemical entity resolution and compared them with Whatizit, a popular-dictionary-based method. Our methods outperformed the dictionary-based method in all tasks, yielding an improvement in F-measure of 20% for the entity recognition task, 2–5% for the entity-resolution task, and 15% for combined entity recognition and resolution tasks. PMID:25937941
Bo, Arixin; Alarco, Jose; Zhu, Huaiyong; Waclawik, Eric R; Zhan, Haifei; Gu, YuanTong
2017-03-15
Construction of nanoarchitectures requires techniques like joint formation and trimming. For ceramic materials, however, it is extremely difficult to form nanojoints by conventional methods like merging. In this work, we demonstrate that ceramic titanate nanowires (NWs) can be joined by spot melting under electron beam (e-beam) irradiation (EBI). The irradiation fuses the contacted spot of titanate NWs yielding an intact nanojoint. Nanojoints with different morphologies can be produced. The joint structures consist of titanium dioxide (TiO 2 ) rutile, anatase, and titanate phases in the direction away from the e-beam melting spot. The titanate binds to anatase via a crystallographic matching coherent interface (the oxygen atoms at the interface are shared by the two phases) and the anatase solidly binds to the rutile joint. The resulting rutile joint is stable at high temperatures. Additionally, it is demonstrated that the heat production from EBI treated rutile can be utilized to break metal NWs (Ag, Cu, and Ni) apart by spot melting. The required e-beam intensity is considerably mild (75 pA/cm 2 ) which allows visual access and control over the NW melting. Direct melting of Ag and Cu is not applicable under EBI due to their high thermal conductivity even with high current density (500 pA/cm 2 ). Our findings reveal that ceramic nanojoint formation and spot melting at nanoscale are applicable if the properties of nanomaterials are understood and properly utilized.
Preveena, Jagadesan; Bhore, Subhash J.
2013-01-01
Background: In traditional medicine, Tridax procumbens Linn. is used in the treatment of injuries and wounds. The bacterial endophytes (BEs) of medicinal plants could produce medicinally important metabolites found in their hosts; and hence, the involvement of BEs in conferring wound healing properties to T. Procumbens cannot be ruled out. But, we do not know which types of BEs are associated with T. Procumbens. Objective: The objective of this study was to investigate the fast growing and cultivable BEs associated with T. procumbens. Materials and Methods: Leaves and stems of healthy T. Procumbens plants were collected and cultivable BEs were isolated from surface-sterilized leaf and stem tissue samples using Luria-Bertani (LB) agar (medium) at standard conditions. A polymerase chain reaction was employed to amplify 16S rRNA coding gene fragments from the isolates. Cultivable endophytic bacterial isolates (EBIs) were identified using 16S rRNA gene nucleotide sequence similarity based method of bacterial identification. Results: Altogether, 50 culturable EBIs were isolated. 16S rRNA gene nucleotide sequences analysis using the Basic Local Alignment Search Tool (BLAST) revealed identities of the EBIs. Analysis reveals that cultivable Bacillus spp., Cronobacter sakazakii, Enterobacter spp., Lysinibacillus sphaericus, Pantoea spp., Pseudomonas spp. and Terribacillus saccharophilus are associated with T. Procumbens. Conclusion: Based on the results, we conclude that 24 different types of culturable BEs are associated with traditionally used medicinal plant, T. Procumbens, and require further study. PMID:24501447
Novel view synthesis by interpolation over sparse examples
NASA Astrophysics Data System (ADS)
Liang, Bodong; Chung, Ronald C.
2006-01-01
Novel view synthesis (NVS) is an important problem in image rendering. It involves synthesizing an image of a scene at any specified (novel) viewpoint, given some images of the scene at a few sample viewpoints. The general understanding is that the solution should bypass explicit 3-D reconstruction of the scene. As it is, the problem has a natural tie to interpolation, despite that mainstream efforts on the problem have been adopting formulations otherwise. Interpolation is about finding the output of a function f(x) for any specified input x, given a few input-output pairs {(xi,fi):i=1,2,3,...,n} of the function. If the input x is the viewpoint, and f(x) is the image, the interpolation problem becomes exactly NVS. We treat the NVS problem using the interpolation formulation. In particular, we adopt the example-based everything or interpolation (EBI) mechanism-an established mechanism for interpolating or learning functions from examples. EBI has all the desirable properties of a good interpolation: all given input-output examples are satisfied exactly, and the interpolation is smooth with minimum oscillations between the examples. We point out that EBI, however, has difficulty in interpolating certain classes of functions, including the image function in the NVS problem. We propose an extension of the mechanism for overcoming the limitation. We also present how the extended interpolation mechanism could be used to synthesize images at novel viewpoints. Real image results show that the mechanism has promising performance, even with very few example images.
Fast Ion extraction from the MedEBIS
NASA Astrophysics Data System (ADS)
Höltermann, H.; Becker, R.; Kleinod, M.; Müller, I.
2004-01-01
Cancer therapy synchrotrons profit from single turn injection in terms of size, costs and easy operation. The MEdically Dedicated EBIS (MEDEBIS), built in Frankfurt, will deliver short (~1.5 µs) and intense (~1.3 mA) pulses of highly charged light ions (C, N, O) to meet the requirements for therapy facilities. The MEDEBIS operates with an electron beam of 400 mA at 5 keV and a ratio of beam to drift tube of 1/20. Drift tube potentials up to 1.6 kV are switched in some 100 ns to deliver a 1.5 µs ion pulse at an axial field gradient of 6.5 kV/m. On extraction, all potentials applied to the drift tubes are set to a given primary potential to define the extraction gradient. During extraction the drift tubes are not held at constant voltage to avoid spreading out of the pulse due to the restoration of the full space charge depression at locations where ions have already been extracted. To locally distribute the action of the applied potentials the drift tubes are fully interpenetrating each other with tapered fingers. Combining these features result in a potential wall, which follows the extracted ion pulse and produces a compressed short ion pulse for single turn injection. In the future similar constructions could be considered for the RHIS EBIS device or proposed for LHC to provide the advantage with respect to lowest emittance and highest luminosity to the accelerators at BNL and CERN.
Electronics for fast ion extraction from EBIS devices
NASA Astrophysics Data System (ADS)
Höltermann, H.; Becker, R.; Kleinod, M.; Müller, I.
2004-05-01
Future synchrotrons for cancer therapy could profit from single turn injection in terms of size, costs, and ease of operation [O. Kester, R. Becker, and M. Kleinod, Rev. Sci. Instrum. 67 (1996)]. Short (˜1.5 μs) and intense (˜1.3 mA) pulses of highly charged light ions (C6+, N7+, O8+) are a requirement for these future therapy facilities which can be provided by an EBIS ion source. Such a medically dedicated EBIS has an electron beam of 400 mA at 5 keV and needs an electron current density of 100 A/cm2 for a repetition rate of 10 Hz. To obtain a 1.5 μs ion pulse it is necessary to switch the drift tube potentials up to 1.6 kV (for a ratio of beam to drift tube of 1/20) in some 100 ns. To avoid spreading out of the pulse due to the restoration of the full space charge depression at locations where ions have already been extracted, the potentials applied to the drift tubes are changed with time. They will be adjusted for each drift tube according to the transit time of the ion pulse. Furthermore, the drift tubes are fully interpenetrating each other with tapered fingers in order to locally distribute the action of the applied potentials. This provides a potential wall, which is following the extracted ion pulse and results in a compressed short ion pulse for single turn injection into a synchrotron.
A drift chamber constructed of aluminized mylar tubes
NASA Astrophysics Data System (ADS)
Baringer, P.; Jung, C.; Ogren, H. O.; Rust, D. R.
1987-03-01
A thin reliable drift chamber has been constructed to be used near the interaction point of the PEP storage ring in the HRS detector. It is composed of individual drift tubes with aluminized mylar walls.
Wang, Yonghua; Xue, Chenyang; Zhang, Zengxing; Zheng, Hua; Zhang, Wendong; Yan, Shubin
2016-01-01
The analogue of electromagnetically induced transparency in optical ways has shown great potential in optical delay and quantum-information technology due to its flexible design and easy implementation. The chief drawback for these devices is the bad tunability. Here we demonstrate a tunable optical transparency system formed by graphene-silicon microrings which could control the transparent window by electro-optical means. The device consists of cascaded coupled ring resonators and a graphene/graphene capacitor which integrated on one of the rings. By tuning the Fermi level of the graphene sheets, we can modulate the round-trip ring loss so that the transparency window can be dynamically tuned. The results provide a new method for the manipulation and transmission of light in highly integrated optical circuits and quantum information storage devices. PMID:27941895
Spin Transparent Siberian Snake And Spin Rotator With Solenoids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koop, I. A.; Otboyev, A. V.; Shatunov, P. Yu.
2007-06-13
For intermediate energies of electrons and protons it happens that it is more convenient to construct Siberian snakes and spin rotators using solenoidal fields. Strong coupling caused by the solenoids is suppressed by a number of skew and normal quadrupole magnets. More complicate problem of the spin transparency of such devices also can be solved. This paper gives two examples: spin rotator for electron ring in the eRHIC project and Siberian snake for proton (antiproton) storage ring HESR, which cover whole machines working energy region.
NASA Astrophysics Data System (ADS)
Nilsson, Thomas; the NUSTAR Collaboration
2015-11-01
The FAIR facility, under construction at the GSI site in Darmstadt, will be addressing a wealth of outstanding questions within the realm of subatomic, atomic, plasma, bio-physics and applications through a combination of novel accelerators, storage rings and innovative experimental set-ups. One of the key installations is the fragment separator Super-FRS that will be able to deliver an unprecedented range of radioactive ion beams in the energy range of 0-1.5 GeV u-1. These beams will be distributed to three branches, each with its unique domain with respect to beam energies and properties. The high-energy branch will permit reactions with radioactive beams at relativistic energies, whereas the low-energy branch will supply decelerated beams for high-resolution spectroscopy, traps and laser spectroscopy. Finally, the ring branch will uniquely permit stored and cooled exotic beams for a range of methods only possible in a storage ring. Thus, by developing experimental set-ups tailored for these beams, there are several complementary possibilities to gain information on key nuclei and reaction, to further our understanding on contemporary questions within nuclear structure and nuclear astrophysics. This ambitious programme is to be exploited within the nuclear structure, astrophysics and reactions collaboration.
An Orbit And Dispersion Correction Scheme for the PEP II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai, Y.; Donald, M.; Shoaee, H.
2011-09-01
To achieve optimum luminosity in a storage ring it is vital to control the residual vertical dispersion. In the original PEP storage ring, a scheme to control the residual dispersion function was implemented using the ring orbit as the controlling element. The 'best' orbit not necessarily giving the lowest vertical dispersion. A similar scheme has been implemented in both the on-line control code and in the simulation code LEGO. The method involves finding the response matrices (sensitivity of orbit/dispersion at each Beam-Position-Monitor (BPM) to each orbit corrector) and solving in a least squares sense for minimum orbit, dispersion function ormore » both. The optimum solution is usually a subset of the full least squares solution. A scheme of simultaneously correcting the orbits and dispersion has been implemented in the simulation code and on-line control system for PEP-II. The scheme is based on the eigenvector decomposition method. An important ingredient of the scheme is to choose the optimum eigenvectors that minimize the orbit, dispersion and corrector strength. Simulations indicate this to be a very effective way to control the vertical residual dispersion.« less
Kinoform optics applied to X-ray photon correlation spectroscopy.
Sandy, A R; Narayanan, S; Sprung, M; Su, J-D; Evans-Lutterodt, K; Isakovic, A F; Stein, A
2010-05-01
Moderate-demagnification higher-order silicon kinoform focusing lenses have been fabricated to facilitate small-angle X-ray photon correlation spectroscopy (XPCS) experiments. The geometric properties of such lenses, their focusing performance and their applicability for XPCS measurements are described. It is concluded that one-dimensional vertical X-ray focusing via silicon kinoform lenses significantly increases the usable coherent flux from third-generation storage-ring light sources for small-angle XPCS experiments.
The Electron Beam Ion Source (EBIS)
Brookhaven Lab
2017-12-09
Brookhaven National Lab has successfully developed a new pre-injector system, called the Electron Beam Ion Source, for the Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory science programs. The first of several planned improvemen
Report of the New Rings Study Group
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holmes, S.D.; Dugan, G.; Marriner, J.
1987-10-19
We have taken the approach here of trying to understand both the feasibility and practicality of varied options for new rings at Fermilab, rather than trying to produce a single detailed design. In other words, this document is not a design report and should not be construed as such. Our perception of the potential needs for new rings (in order of priority) is as follows: Antiproton Storage and/or Recovery: A facility for storing up to 4 x 10/sup 12/ antiprotons is needed. Recovery of antiprotons from the collider becomes a viable option if the luminosity is indeed dominated by emittancemore » dilution rather than beam loss. New or Post-Booster: The goal here would be to inject into the existing Main Ring above transition. Improved performance of the Main Ring would be anticipated. New Main Ring: Advantages would include better emittance preservation, a faster cycle time for antiproton production, and the removal of interference/backgrounds at the B0 and D0 detectors. We discuss in this paper various scenarios based on one or more combinations of the above possibilities. 14 figs., 10 tabs.« less
ERIC Educational Resources Information Center
School Science Review, 1980
1980-01-01
Outlines a variety of laboratory procedures, discussions, and demonstrations including Brownian motion, a synchronous motor, jet engine, atmospheric pressure vortex ring machines, solid chemical dispensing, testing household detergents, wallchart storage, pollution by industrial chemicals, an optical illusion, and buoyancy. (GS)
Software package for modeling spin-orbit motion in storage rings
NASA Astrophysics Data System (ADS)
Zyuzin, D. V.
2015-12-01
A software package providing a graphical user interface for computer experiments on the motion of charged particle beams in accelerators, as well as analysis of obtained data, is presented. The software package was tested in the framework of the international project on electric dipole moment measurement JEDI (Jülich Electric Dipole moment Investigations). The specific features of particle spin motion imply the requirement to use a cyclic accelerator (storage ring) consisting of electrostatic elements, which makes it possible to preserve horizontal polarization for a long time. Computer experiments study the dynamics of 106-109 particles in a beam during 109 turns in an accelerator (about 1012-1015 integration steps for the equations of motion). For designing an optimal accelerator structure, a large number of computer experiments on polarized beam dynamics are required. The numerical core of the package is COSY Infinity, a program for modeling spin-orbit dynamics.
Spin Filtering in Storage Rings
NASA Astrophysics Data System (ADS)
Nikolaev, N. N.; Pavlov, F. F.
The spin filtering in storage rings is based on a multiple passage of a stored beam through a polarized internal gas target. Apart from the polarization by the spin-dependent transmission, a unique geometrical feature of interaction with the target in such a filtering process, pointed out by H.O. Meyer,1 is a scattering of stored particles within the beam. A rotation of the spin in the scattering process affects the polarization buildup. We derive here a quantum-mechanical evolution equation for the spin-density matrix of a stored beam which incorporates the scattering within the beam. We show how the interplay of the transmission and scattering within the beam changes from polarized electrons to polarized protons in the atomic target. After discussions of the FILTEX results on the filtering of stored protons,2 we comment on the strategy of spin filtering of antiprotons for the PAX experiment at GSI FAIR.3.
Direct Observation of Spatiotemporal Dynamics of Short Electron Bunches in Storage Rings
NASA Astrophysics Data System (ADS)
Evain, C.; Roussel, E.; Le Parquier, M.; Szwaj, C.; Tordeux, M.-A.; Brubach, J.-B.; Manceron, L.; Roy, P.; Bielawski, S.
2017-02-01
In recent synchrotron radiation facilities, the use of short (picosecond) electron bunches is a powerful method for producing giant pulses of terahertz coherent synchrotron radiation. Here we report on the first direct observation of these pulse shapes with a few picoseconds resolution, and of their dynamics over a long time. We thus confirm in a very direct way the theories predicting an interplay between two physical processes. Below a critical bunch charge, we observe a train of identical THz pulses (a broadband Terahertz comb) stemming from the shortness of the electron bunches. Above this threshold, a large part of the emission is dominated by drifting structures, which appear through spontaneous self-organization. These challenging single-shot THz recordings are made possible by using a recently developed photonic time stretch detector with a high sensitivity. The experiment has been realized at the SOLEIL storage ring.
The trigger system for the external target experiment in the HIRFL cooling storage ring
NASA Astrophysics Data System (ADS)
Li, Min; Zhao, Lei; Liu, Jin-Xin; Lu, Yi-Ming; Liu, Shu-Bin; An, Qi
2016-08-01
A trigger system was designed for the external target experiment in the Cooling Storage Ring (CSR) of the Heavy Ion Research Facility in Lanzhou (HIRFL). Considering that different detectors are scattered over a large area, the trigger system is designed based on a master-slave structure and fiber-based serial data transmission technique. The trigger logic is organized in hierarchies, and flexible reconfiguration of the trigger function is achieved based on command register access or overall field-programmable gate array (FPGA) logic on-line reconfiguration controlled by remote computers. We also conducted tests to confirm the function of the trigger electronics, and the results indicate that this trigger system works well. Supported by the National Natural Science Foundation of China (11079003), the Knowledge Innovation Program of the Chinese Academy of Sciences (KJCX2-YW-N27), and the CAS Center for Excellence in Particle Physics (CCEPP).
NASA Astrophysics Data System (ADS)
Krantz, C.; Novotný, O.; Becker, A.; George, S.; Grieser, M.; Hahn, R. von; Meyer, C.; Schippers, S.; Spruck, K.; Vogel, S.; Wolf, A.
2017-04-01
We have used a single-particle detector system, based on secondary electron emission, for counting low-energetic (∼keV/u) massive products originating from atomic and molecular ion reactions in the electrostatic Cryogenic Storage Ring (CSR). The detector is movable within the cryogenic vacuum chamber of CSR, and was used to measure production rates of a variety of charged and neutral daughter particles. In operation at a temperature of ∼ 6 K , the detector is characterised by a high dynamic range, combining a low dark event rate with good high-rate particle counting capability. On-line measurement of the pulse height distributions proved to be an important monitor of the detector response at low temperature. Statistical pulse-height analysis allows to infer the particle detection efficiency of the detector, which has been found to be close to unity also in cryogenic operation at 6 K.
Dissociative recombination measurements of NH{sup +} using an ion storage ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Novotný, O.; Savin, D. W.; Berg, M.
We have investigated dissociative recombination (DR) of NH{sup +} with electrons using a merged beams configuration at the TSR heavy-ion storage ring located at the Max Planck Institute for Nuclear Physics in Heidelberg, Germany. We present our measured absolute merged-beams recombination rate coefficient for collision energies from 0 to 12 eV. From these data, we have extracted a cross section, which we have transformed to a plasma rate coefficient for the collisional plasma temperature range from T {sub pl} = 10 to 18,000 K. We show that the NH{sup +} DR rate coefficient data in current astrochemical models are underestimatedmore » by up to a factor of approximately nine. Our new data will result in predicted NH{sup +} abundances lower than those calculated by present models. This is in agreement with the sensitivity limits of all observations attempting to detect NH{sup +} in interstellar clouds.« less
Linear transformer driver for pulse generation
Kim, Alexander A; Mazarakis, Michael G; Sinebryukhov, Vadim A; Volkov, Sergey N; Kondratiev, Sergey S; Alexeenko, Vitaly M; Bayol, Frederic; Demol, Gauthier; Stygar, William A
2015-04-07
A linear transformer driver includes at least one ferrite ring positioned to accept a load. The linear transformer driver also includes a first power delivery module that includes a first charge storage devices and a first switch. The first power delivery module sends a first energy in the form of a first pulse to the load. The linear transformer driver also includes a second power delivery module including a second charge storage device and a second switch. The second power delivery module sends a second energy in the form of a second pulse to the load. The second pulse has a frequency that is approximately three times the frequency of the first pulse. The at least one ferrite ring is positioned to force the first pulse and the second pulse to the load by temporarily isolating the first pulse and the second pulse from an electrical ground.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rawolle, M.; Koerstgens, V.; Ruderer, M. A.
2012-10-15
Grazing incidence small angle x-ray scattering (GISAXS) is a powerful technique for morphology investigation of nanostructured thin films. GISAXS measurements at the newly installed P03 beamline at the storage ring PETRA III in Hamburg, Germany, are compared to the GISAXS data from the beamline BW4 at the storage ring DORIS III, which had been used extensively for GISAXS investigations in the past. As an example, a titania thin film sponge structure is investigated. Compared to BW4, at beamline P03 the resolution of larger structures is slightly improved and a higher incident flux leads to a factor of 750 in scatteredmore » intensity. Therefore, the acquisition time in GISAXS geometry is reduced significantly at beamline P03.« less
A New Hard X-ray Wiggler for DORIS III
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tischer, M.; Gumprecht, L.; Pflueger, J.
2007-01-19
A 4 m long hard X-ray wiggler has been built and installed in the DORIS III storage ring at DESY. The device replaces an old wiggler especially designed for angiography studies. Future use of this beamline at the HARWI straight section has been dedicated to hard X-ray scattering and diffraction experiments for material science and geological investigations. The required energy range is from 30 keV to about 200 keV with emphasis on the {approx}100 keV spectral range. The magnet configuration corresponds to a hybrid structure with additional side magnets to achieve a 2 T peak field for the specified periodmore » length of 110 mm. The wiggler position in the storage ring has been moved 8 m upstream into the next cell which allowed for reduction of the minimum magnetic wiggler gap to 14 mm.« less
Fluorescence dynamics of biological systems using synchrotron radiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gratton, E.; Mantulin, W.W.; Weber, G.
1996-09-01
A beamline for time-resolved fluorescence spectroscopy of biological systems is under construction at the Synchrotron Radiation Center. The fluorometer, operating in the frequency domain, will take advantage of the time structure of the synchrotron radiation light pulses to determine fluorescence lifetimes. Using frequency-domain techniques, the instrument can achieve an ultimate time resolution on the order of picoseconds. Preliminary experiments have shown that reducing the intensity of one of the fifteen electron bunches in the storage ring allows measurement of harmonic frequencies equivalent to the single-bunch mode. This mode of operation of the synchrotron significantly extends the range of lifetimes thatmore » can be measured. The wavelength range (encompassing the visible and ultraviolet), the range of measurable lifetimes, and the stability and reproducibility of the storage ring pulses should make this beamline a versatile tool for the investigation of the complex fluorescence decay of biological systems. {copyright} {ital 1996 American Institute of Physics.}« less
HIGH-ENERGY X-RAY PINHOLE CAMERA FOR HIGH-RESOLUTION ELECTRON BEAM SIZE MEASUREMENTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, B.; Morgan, J.; Lee, S.H.
The Advanced Photon Source (APS) is developing a multi-bend achromat (MBA) lattice based storage ring as the next major upgrade, featuring a 20-fold reduction in emittance. Combining the reduction of beta functions, the electron beam sizes at bend magnet sources may be reduced to reach 5 – 10 µm for 10% vertical coupling. The x-ray pinhole camera currently used for beam size monitoring will not be adequate for the new task. By increasing the operating photon energy to 120 – 200 keV, the pinhole camera’s resolution is expected to reach below 4 µm. The peak height of the pinhole imagemore » will be used to monitor relative changes of the beam sizes and enable the feedback control of the emittance. We present the simulation and the design of a beam size monitor for the APS storage ring.« less
The Muon g-2 Experiment overview and status as of June 2016
Holzbauer, J. L.
2016-12-09
The Muon g-2 Experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will also extend the search for the electric dipole moment (EDM) of the muon by approximately two orders of magnitude, with a sensitivity down to 10 -21 e.cm. Both of these measurements are made by combining a precise measurement of the 1.45T storage ring magnetic field with an analysis of the modulation of the decay rate of higher-energy positrons (from anti-muons),more » recorded by 24 calorimeters and 3 straw tracking detectors. Furthermore, the recent progress in the alignment of the electrostatic quadrapole plates and the trolley rails inside the vacuum chambers, and in establishing the uniform storage ring magnetic field will be described.« less
Storage ring two-color free-electron laser
Yan, J.; Hao, H.; Li, J. Y.; ...
2016-07-05
We report a systematic experimental study of a storage ring two-color free-electron laser (FEL) operating simultaneously in the infrared (IR) and ultraviolet (UV) wavelength regions. The two-color FEL lasing has been realized using a pair of dual-band high-reflectivity FEL mirrors with two different undulator configurations. We have demonstrated independent wavelength tuning in a wide range for each lasing color, as well as harmonically locked wavelength tuning when the UV lasing occurs at the second harmonic of the IR lasing. Precise power control of two-color lasing with good power stability has also been achieved. In addition, the impact of the degradationmore » of FEL mirrors on the two-color FEL operation is reported. Moreover, we have investigated the temporal structures of the two-color FEL beams, showing simultaneous two-color micropulses with their intensity modulations displayed as FEL macropulses.« less
Introduction to the magnet and vacuum systems of an electron storage ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weng, W.T.
An accelerator or storage ring complex is a concerted interplay of various functional systems. For the convenience of discussion we can divide it into the following systems: injector, magnet, RF, vacuum, instrumentation and control. In addition, the conventional construction of the building and radiation safety consideration are also needed and finally the beam lines, detector, data acquisition and analysis set-ups for research programs. Dr. L. Teng has given a comprehensive review of the whole complex and the operation of such a facility. I concentrate on the description of magnet and vacuum systems. Only the general function of each system andmore » the basic design concepts will be introduced, no detailed engineering practice will be given which will be best done after a machine design is produced. For further understanding and references a table of bibliography is provided at the end of the paper.« less
NASA Astrophysics Data System (ADS)
Steiger, J.; Beck, B. R.; Gruber, L.; Church, D. A.; Holder, J. P.; Schneider, D.
1999-01-01
Storage rings and Penning traps are being used to study ions in their highest charge states. Both devices must have the capability for ion cooling in order to perform high precision measurements such as mass spectrometry and laser spectroscopy. This is accomplished in storage rings in a merged beam arrangement where a cold electron beam moves at the speed of the ions. In RETRAP, a Penning trap located at Lawrence Livermore National Laboratory, a sympathetic laser/ion cooling scheme has been implemented. In a first step, singly charged beryllium ions are cooled electronically by a tuned circuit and optically by a laser. Then hot, highly charged ions are merged into the cold Be plasma. By collisions, their kinetic energy is reduced to the temperature of the Be plasma. First experiments indicate that the highly charged ions form a strongly coupled plasma with a Coulomb coupling parameter exceeding 1000.
Field Quality from Tolerance Stack-up In R&D Quadrupoles for the Advanced Photon Source Upgrade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, J.; Jaski, M.; Dejus, R.
2016-10-01
The Advanced Photon Source (APS) at Argonne National Laboratory (ANL) is considering upgrading the current double-bend, 7-GeV, 3rd generation storage ring to a 6-GeV, 4th generation storage ring with a Multibend Achromat (MBA) lattice. In this study, a novel method is proposed to determine fabrication and assembly tolerances through a combination of magnetic and mechanical tolerance analyses. Mechanical tolerance stackup analyses using Teamcenter Variation Analysis are carried out to determine the part and assembly level fabrication tolerances. Finite element analyses using OPERA are conducted to estimate the effect of fabrication and assembly errors on the magnetic field of a quadrupolemore » magnet and to determine the allowable tolerances to achieve the desired magnetic performance. Finally, results of measurements in R&D quadrupole prototypes are compared with the analysis results.« less
Impedance computations and beam-based measurements: A problem of discrepancy
NASA Astrophysics Data System (ADS)
Smaluk, Victor
2018-04-01
High intensity of particle beams is crucial for high-performance operation of modern electron-positron storage rings, both colliders and light sources. The beam intensity is limited by the interaction of the beam with self-induced electromagnetic fields (wake fields) proportional to the vacuum chamber impedance. For a new accelerator project, the total broadband impedance is computed by element-wise wake-field simulations using computer codes. For a machine in operation, the impedance can be measured experimentally using beam-based techniques. In this article, a comparative analysis of impedance computations and beam-based measurements is presented for 15 electron-positron storage rings. The measured data and the predictions based on the computed impedance budgets show a significant discrepancy. Three possible reasons for the discrepancy are discussed: interference of the wake fields excited by a beam in adjacent components of the vacuum chamber, effect of computation mesh size, and effect of insufficient bandwidth of the computed impedance.
The Muon g-2 Experiment Overview and Status as of June 2016
NASA Astrophysics Data System (ADS)
Holzbauer, J.
2016-11-01
The Muon g-2 Experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will also extend the search for the electric dipole moment (EDM) of the muon by approximately two orders of magnitude, with a sensitivity down to 10-21 e.cm. Both of these measurements are made by combining a precise measurement of the 1.45T storage ring magnetic field with an analysis of the modulation of the decay rate of higher-energy positrons (from anti-muons), recorded by 24 calorimeters and 3 straw tracking detectors. The recent progress in the alignment of the electrostatic quadrapole plates and the trolley rails inside the vacuum chambers, and in establishing the uniform storage ring magnetic field will be described.
New beam-position monitor system for upgraded Photon Factory storage ring.
Haga, K; Honda, T; Tadano, M; Obina, T; Kasuga, T
1998-05-01
Accompanying the brilliance-upgrading project at the Photon Factory storage ring, the beam-position monitor (BPM) system has been renovated. The new system was designed to enable precise and fast measurements to correct the closed-orbit distortion (COD), as well as to feed back the orbit position during user runs. There are 42 BPMs newly installed, amounting to a total of 65 BPMs. All of the BPMs are calibrated on the test bench using a coaxially strung metallic wire. The measured electrical offsets are typically 200 micro m in both directions, which is 1/2-1/3 of those of the old-type BPMs. In the signal-processing system, PIN diode switches are employed in order to improve reliability. In the fastest mode, this system is capable of measuring COD within about 10 ms; this fast acquisition will allow fast suppression of the beam movement for frequencies up to 50 Hz using a global feedback system.
The MAX IV storage ring project
Tavares, Pedro F.; Leemann, Simon C.; Sjöström, Magnus; Andersson, Åke
2014-01-01
The MAX IV facility, currently under construction in Lund, Sweden, features two electron storage rings operated at 3 GeV and 1.5 GeV and optimized for the hard X-ray and soft X-ray/VUV spectral ranges, respectively. A 3 GeV linear accelerator serves as a full-energy injector into both rings as well as a driver for a short-pulse facility, in which undulators produce X-ray pulses as short as 100 fs. The 3 GeV ring employs a multibend achromat (MBA) lattice to achieve, in a relatively short circumference of 528 m, a bare lattice emittance of 0.33 nm rad, which reduces to 0.2 nm rad as insertion devices are added. The engineering implementation of the MBA lattice raises several technological problems. The large number of strong magnets per achromat calls for a compact design featuring small-gap combined-function magnets grouped into cells and sharing a common iron yoke. The small apertures lead to a low-conductance vacuum chamber design that relies on the chamber itself as a distributed copper absorber for the heat deposited by synchrotron radiation, while non-evaporable getter (NEG) coating provides for reduced photodesorption yields and distributed pumping. Finally, a low main frequency (100 MHz) is chosen for the RF system yielding long bunches, which are further elongated by passively operated third-harmonic Landau cavities, thus alleviating collective effects, both coherent (e.g. resistive wall instabilities) and incoherent (intrabeam scattering). In this paper, we focus on the MAX IV 3 GeV ring and present the lattice design as well as the engineering solutions to the challenges inherent to such a design. As the first realisation of a light source based on the MBA concept, the MAX IV 3 GeV ring offers an opportunity for validation of concepts that are likely to be essential ingredients of future diffraction-limited light sources. PMID:25177978