Sample records for ebis test stand

  1. Design of an EBIS charge breeder system for rare-isotope beams

    NASA Astrophysics Data System (ADS)

    Park, Young-Ho; Son, Hyock-Jun; Kim, Jongwon

    2016-09-01

    Rare-isotope beams will be produced by using the isotope separation on-line (ISOL) system at the Rare Isotope Science Project (RISP). A proton cyclotron is the driver accelerator for ISOL targets, and uranium carbide (UCx) will be a major target material. An isotope beam of interest extracted from the target will be ionized and selected by using a mass separator. The beam emittance will then be reduced by using a radio-frequency quadrupole (RFQ) cooler before the beam is injected into the electron-beam ion-source (EBIS) charge breeder (CB). The maximum electron beam current of the EBIS is 3 A from a cathode made of IrCe in an applied magnetic field of 0.2 T. The size of the electron beam is compressed by magnetic fields of up to 6 T caused in the charge-breeding region by a superconducting solenoid. The design of EBIS-CB was performed by using mechanics as well as beam optics. A test stand for the electron gun and its collector, which can take an electron-beam power of 20 kW, are under construction. The gun assembly was first tested by using a high-voltage pulse so as to measure its perveance. The design of the EBIS, along with its test stand, is described.

  2. First test of BNL electron beam ion source with high current density electron beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikin, Alexander, E-mail: pikin@bnl.gov; Alessi, James G., E-mail: pikin@bnl.gov; Beebe, Edward N., E-mail: pikin@bnl.gov

    A new electron gun with electrostatic compression has been installed at the Electron Beam Ion Source (EBIS) Test Stand at BNL. This is a collaborative effort by BNL and CERN teams with a common goal to study an EBIS with electron beam current up to 10 A, current density up to 10,000 A/cm{sup 2} and energy more than 50 keV. Intensive and pure beams of heavy highly charged ions with mass-to-charge ratio < 4.5 are requested by many heavy ion research facilities including NASA Space Radiation Laboratory (NSRL) at BNL and HIE-ISOLDE at CERN. With a multiampere electron gun, themore » EBIS should be capable of delivering highly charged ions for both RHIC facility applications at BNL and for ISOLDE experiments at CERN. Details of the electron gun simulations and design, and the Test EBIS electrostatic and magnetostatic structures with the new electron gun are presented. The experimental results of the electron beam transmission are given.« less

  3. Simulation of 10 A electron-beam formation and collection for a high current electron-beam ion source

    NASA Astrophysics Data System (ADS)

    Kponou, A.; Beebe, E.; Pikin, A.; Kuznetsov, G.; Batazova, M.; Tiunov, M.

    1998-02-01

    Presented is a report on the development of an electron-beam ion source (EBIS) for the relativistic heavy ion collider at Brookhaven National Laboratory (BNL) which requires operating with a 10 A electron beam. This is approximately an order of magnitude higher current than in any existing EBIS device. A test stand is presently being designed and constructed where EBIS components will be tested. It will be reported in a separate paper at this conference. The design of the 10 A electron gun, drift tubes, and electron collector requires extensive computer simulations. Calculations have been performed at Novosibirsk and BNL using two different programs, SAM and EGUN. Results of these simulations will be presented.

  4. Measurements of charge state breeding efficiency at BNL test EBIS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kondrashev, S.; Alessi, J.; Beebe, E.N.

    Charge breeding of singly charged ions is required to efficiently accelerate rare isotope ion beams for nuclear and astrophysics experiments, and to enhance the accuracy of low-energy Penning trap-assisted spectroscopy. An efficient charge breeder for the Californium Rare Isotope Breeder Upgrade (CARIBU) to the ANL Tandem Linear Accelerator System (ATLAS) facility is being developed using the BNL Test Electron Beam Ion Source (Test EBIS) as a prototype. Parameters of the CARIBU EBIS charge breeder are similar to those of the BNL Test EBIS except the electron beam current will be adjustable in the range from 1 to 2 {angstrom}. Themore » electron beam current density in the CARIBU EBIS trap will be significantly higher than in existing operational charge state breeders based on the EBIS concept. The charge state breeding efficiency is expected to be about 25% for the isotope ions extracted from the CARIBU. For the success of our EBIS project, it is essential to demonstrate high breeding efficiency at the BNL Test EBIS tuned to the regime close to the parameters of the CARIBU EBIS at ANL. The breeding efficiency optimization and measurements have been successfully carried out using a Cs{sup +} surface ionization ion source for externally pulsed injection into the BNL Test EBIS. A Cs{sup +} ion beam with a total number of ions of 5 x 10{sup 8} and optimized pulse length of 70 {mu}s has been injected into the Test EBIS and charge-bred for 5.3 ms for two different electron beam currents 1 and 1.5 {angstrom}. In these experiments we have achieved 70% injection/extraction efficiency and breeding efficiency into the most abundant charge state 17%.« less

  5. The student experience of applied equivalence-based instruction for neuroanatomy teaching.

    PubMed

    Greville, W James; Dymond, Simon; Newton, Philip M

    2016-01-01

    Esoteric jargon and technical language are potential barriers to the teaching of science and medicine. Effective teaching strategies which address these barriers are desirable. Here, we created and evaluated the effectiveness of stand-alone 'equivalence-based instruction' (EBI) learning resources wherein the teaching of a small number of direct relationships between stimuli (e.g., anatomical regions, their function, and pathology) results in the learning of higher numbers of untaught relationships. We used a pre and post test design to assess students' learning of the relations. Resources were evaluated by students for perceived usefulness and confidence in the topic. Three versions of the resources were designed, to explore learning parameters such as the number of stimulus classes and the number of relationships within these classes. We show that use of EBI resulted in demonstrable learning of material that had not been directly taught. The resources were well received by students, even when the quantity of material to be learned was high. There was a strong desire for more EBI-based teaching. The findings are discussed in the context of an ongoing debate surrounding 'rote' vs. 'deep' learning, and the need to balance this debate with considerations of cognitive load and esoteric jargon routinely encountered during the study of medicine. These standalone EBI resources were an effective, efficient and well-received method for teaching neuroanatomy to medical students. The approach may be of benefit to other subjects with abundant technical jargon, science and other areas of medicine.

  6. The student experience of applied equivalence-based instruction for neuroanatomy teaching

    PubMed Central

    2016-01-01

    Purpose Esoteric jargon and technical language are potential barriers to the teaching of science and medicine. Effective teaching strategies which address these barriers are desirable. Here, we created and evaluated the effectiveness of stand-alone ‘equivalence-based instruction’ (EBI) learning resources wherein the teaching of a small number of direct relationships between stimuli (e.g., anatomical regions, their function, and pathology) results in the learning of higher numbers of untaught relationships. Methods We used a pre and post test design to assess students’ learning of the relations. Resources were evaluated by students for perceived usefulness and confidence in the topic. Three versions of the resources were designed, to explore learning parameters such as the number of stimulus classes and the number of relationships within these classes. Results We show that use of EBI resulted in demonstrable learning of material that had not been directly taught. The resources were well received by students, even when the quantity of material to be learned was high. There was a strong desire for more EBI-based teaching. The findings are discussed in the context of an ongoing debate surrounding ‘rote’ vs. ‘deep’ learning, and the need to balance this debate with considerations of cognitive load and esoteric jargon routinely encountered during the study of medicine. Conclusion These standalone EBI resources were an effective, efficient and well-received method for teaching neuroanatomy to medical students. The approach may be of benefit to other subjects with abundant technical jargon, science and other areas of medicine. PMID:27649900

  7. Fast and efficient charge breeding of the Californium rare isotope breeder upgrade electron beam ion source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ostroumov, P. N.; Barcikowski, A.; Dickerson, C. A.

    The Electron Beam Ion Source (EBIS), developed to breed CARIBU radioactive beams at ATLAS, is being tested off-line. A unique property of the EBIS is a combination of short breeding times, high repetition rates and a large acceptance. Overall, we have implemented many innovative features during the design and construction of the CARIBU EBIS as compared to the existing EBIS breeders. The offline charge breeding tests are being performed using a surface ionization source that produces singly-charged cesium ions. The main goal of the off-line commissioning is to demonstrate stable operation of the EBIS at a 10 Hz repetition ratemore » and a breeding efficiency into single charge state higher than 15%. These goals have been successfully achieved and exceeded. We have measured (20±0.7)% breeding efficiency into the single charge state of 28+ cesium ions with the breeding time of 28 ms. In general, the current CARIBU EBIS operational parameters can provide charge breeding of any ions in the full mass range of periodic table with high efficiency, short breeding times and sufficiently low charge-to-mass ratio, 1/6.3 for the heaviest masses, for further acceleration in ATLAS. In this paper we discuss the parameters of the EBIS and the charge breeding results in a pulsed injection mode with repetition rates up to 10 Hz.« less

  8. Fast and efficient charge breeding of the Californium rare isotope breeder upgrade electron beam ion source

    DOE PAGES

    Ostroumov, P. N.; Barcikowski, A.; Dickerson, C. A.; ...

    2015-08-28

    The Electron Beam Ion Source (EBIS), developed to breed Californium Rare Isotope Breeder Upgrade (CARIBU) radioactive beams at Argonne Tandem Linac Accelerator System (ATLAS), is being tested off-line. A unique property of the EBIS is a combination of short breeding times, high repetition rates, and a large acceptance. Overall, we have implemented many innovative features during the design and construction of the CARIBU EBIS as compared to the existing EBIS breeders. The off-line charge breeding tests are being performed using a surface ionization source that produces singly charged cesium ions. The main goal of the off-line commissioning is to demonstratemore » stable operation of the EBIS at a 10 Hz repetition rate and a breeding efficiency into single charge state higher than 15%. These goals have been successfully achieved and exceeded. We have measured (20% ± 0.7%) breeding efficiency into the single charge state of 28+ cesium ions with the breeding time of 28 ms. In general, the current CARIBU EBIS operational parameters can provide charge breeding of any ions in the full mass range of periodic table with high efficiency, short breeding times, and sufficiently low charge-to-mass ratio, 1/6.3 for the heaviest masses, for further acceleration in ATLAS. In this study, we discuss the parameters of the EBIS and the charge breeding results in a pulsed injection mode with repetition rates up to 10 Hz.« less

  9. Fast and efficient charge breeding of the Californium rare isotope breeder upgrade electron beam ion source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ostroumov, P. N.; Barcikowski, A.; Dickerson, C. A.

    The Electron Beam Ion Source (EBIS), developed to breed Californium Rare Isotope Breeder Upgrade (CARIBU) radioactive beams at Argonne Tandem Linac Accelerator System (ATLAS), is being tested off-line. A unique property of the EBIS is a combination of short breeding times, high repetition rates, and a large acceptance. Overall, we have implemented many innovative features during the design and construction of the CARIBU EBIS as compared to the existing EBIS breeders. The off-line charge breeding tests are being performed using a surface ionization source that produces singly charged cesium ions. The main goal of the off-line commissioning is to demonstratemore » stable operation of the EBIS at a 10 Hz repetition rate and a breeding efficiency into single charge state higher than 15%. These goals have been successfully achieved and exceeded. We have measured (20% ± 0.7%) breeding efficiency into the single charge state of 28+ cesium ions with the breeding time of 28 ms. In general, the current CARIBU EBIS operational parameters can provide charge breeding of any ions in the full mass range of periodic table with high efficiency, short breeding times, and sufficiently low charge-to-mass ratio, 1/6.3 for the heaviest masses, for further acceleration in ATLAS. In this study, we discuss the parameters of the EBIS and the charge breeding results in a pulsed injection mode with repetition rates up to 10 Hz.« less

  10. Fast and efficient charge breeding of the Californium rare isotope breeder upgrade electron beam ion source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ostroumov, P. N., E-mail: ostroumov@anl.gov; Barcikowski, A.; Dickerson, C. A.

    The Electron Beam Ion Source (EBIS), developed to breed Californium Rare Isotope Breeder Upgrade (CARIBU) radioactive beams at Argonne Tandem Linac Accelerator System (ATLAS), is being tested off-line. A unique property of the EBIS is a combination of short breeding times, high repetition rates, and a large acceptance. Overall, we have implemented many innovative features during the design and construction of the CARIBU EBIS as compared to the existing EBIS breeders. The off-line charge breeding tests are being performed using a surface ionization source that produces singly charged cesium ions. The main goal of the off-line commissioning is to demonstratemore » stable operation of the EBIS at a 10 Hz repetition rate and a breeding efficiency into single charge state higher than 15%. These goals have been successfully achieved and exceeded. We have measured (20% ± 0.7%) breeding efficiency into the single charge state of 28+ cesium ions with the breeding time of 28 ms. In general, the current CARIBU EBIS operational parameters can provide charge breeding of any ions in the full mass range of periodic table with high efficiency, short breeding times, and sufficiently low charge-to-mass ratio, 1/6.3 for the heaviest masses, for further acceleration in ATLAS. In this paper, we discuss the parameters of the EBIS and the charge breeding results in a pulsed injection mode with repetition rates up to 10 Hz.« less

  11. Electron-beam-ion-source (EBIS) modeling progress at FAR-TECH, Inc

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, J. S., E-mail: kim@far-tech.com; Zhao, L., E-mail: kim@far-tech.com; Spencer, J. A., E-mail: kim@far-tech.com

    FAR-TECH, Inc. has been developing a numerical modeling tool for Electron-Beam-Ion-Sources (EBISs). The tool consists of two codes. One is the Particle-Beam-Gun-Simulation (PBGUNS) code to simulate a steady state electron beam and the other is the EBIS-Particle-In-Cell (EBIS-PIC) code to simulate ion charge breeding with the electron beam. PBGUNS, a 2D (r,z) electron gun and ion source simulation code, has been extended for efficient modeling of EBISs and the work was presented previously. EBIS-PIC is a space charge self-consistent PIC code and is written to simulate charge breeding in an axisymmetric 2D (r,z) device allowing for full three-dimensional ion dynamics.more » This 2D code has been successfully benchmarked with Test-EBIS measurements at Brookhaven National Laboratory. For long timescale (< tens of ms) ion charge breeding, the 2D EBIS-PIC simulations take a long computational time making the simulation less practical. Most of the EBIS charge breeding, however, may be modeled in 1D (r) as the axial dependence of the ion dynamics may be ignored in the trap. Where 1D approximations are valid, simulations of charge breeding in an EBIS over long time scales become possible, using EBIS-PIC together with PBGUNS. Initial 1D results are presented. The significance of the magnetic field to ion dynamics, ion cooling effects due to collisions with neutral gas, and the role of Coulomb collisions are presented.« less

  12. Effect of EBI3 on radiation-induced immunosuppression of cervical cancer HeLa cells by regulating Treg cells through PD-1/PD-L1 pathway.

    PubMed

    Zhang, Song-An; Niyazi, Hu-Er-Xi-Dan; Hong, Wen; Tuluwengjiang, Gu-Li-Xian; Zhang, Lei; Zhang, Yang; Su, Wei-Peng; Bao, Yong-Xing

    2017-03-01

    This study aimed to investigate the effect of EBI3 on radiation-induced immunosuppression of cervical cancer HeLa cells by regulating Treg cells through PD-1/PD-L1 signaling pathway. A total of 43 adult female Wistar rats were selected and injected with HeLa cells in the caudal vein to construct a rat model of cervical cancer. All model rats were randomly divided into the radiotherapy group ( n = 31) and the control group ( n = 12). The immunophenotype of Treg cells was detected by the flow cytometry. The protein expressions of EBI3, PD-1, and PD-L1 in cervical cancer tissues were tested by the streptavidin-peroxidase method. HeLa cells in the logarithmic growth phase were divided into four groups: the blank, the negative control group, the EBI3 mimics group, and the EBI3 inhibitors group. Western blotting was used to detect PD-1 and PD-L1 protein expressions. MTT assay was performed to measure the proliferation of Treg cells. Flow cytometry was used to detect cell cycle and apoptosis, and CD4 + /CD8 + T cell ratio in each group. Compared with before and 1 week after radiotherapy, the percentages of CD4 + T cells and CD8 + T cells were significantly decreased in the radiotherapy group at 1 month after radiotherapy. Furthermore, down-regulation of EBI3 and up-regulation of PD-1 and PD-L1 were observed in cervical cancer tissues at 1 month after radiotherapy. In comparison to the blank and negative control groups, increased expression of EBI3 and decreased expressions of PD-1 and PD-L1 were found in the EBI3 mimics group. However, the EBI3 inhibitors group had a lower expression of EBI3 and higher expressions of PD-1 and PD-L1 than those in the blank and negative control groups. The EBI3 mimics group showed an increase in the optical density value (0.43 ± 0.05), while a decrease in the optical density value (0.31 ± 0.02) was found in the EBI3 inhibitors group. Moreover, compared with the blank and negative control groups, the apoptosis rates of Treg/CD4 + T/CD8 + T cells were decreased in the EBI3 mimics group, but the EBI3 inhibitors group exhibited an increase in apoptosis rate. In conclusion, over-expression of EBI3 could reduce the apoptosis of Treg/CD4 + T/CD8 + T cells and prevent radiation-induced immunosuppression of cervical cancer HeLa cells by inhibiting the activation of PD-1/PD-L1 signaling pathway.

  13. libChEBI: an API for accessing the ChEBI database.

    PubMed

    Swainston, Neil; Hastings, Janna; Dekker, Adriano; Muthukrishnan, Venkatesh; May, John; Steinbeck, Christoph; Mendes, Pedro

    2016-01-01

    ChEBI is a database and ontology of chemical entities of biological interest. It is widely used as a source of identifiers to facilitate unambiguous reference to chemical entities within biological models, databases, ontologies and literature. ChEBI contains a wealth of chemical data, covering over 46,500 distinct chemical entities, and related data such as chemical formula, charge, molecular mass, structure, synonyms and links to external databases. Furthermore, ChEBI is an ontology, and thus provides meaningful links between chemical entities. Unlike many other resources, ChEBI is fully human-curated, providing a reliable, non-redundant collection of chemical entities and related data. While ChEBI is supported by a web service for programmatic access and a number of download files, it does not have an API library to facilitate the use of ChEBI and its data in cheminformatics software. To provide this missing functionality, libChEBI, a comprehensive API library for accessing ChEBI data, is introduced. libChEBI is available in Java, Python and MATLAB versions from http://github.com/libChEBI, and provides full programmatic access to all data held within the ChEBI database through a simple and documented API. libChEBI is reliant upon the (automated) download and regular update of flat files that are held locally. As such, libChEBI can be embedded in both on- and off-line software applications. libChEBI allows better support of ChEBI and its data in the development of new cheminformatics software. Covering three key programming languages, it allows for the entirety of the ChEBI database to be accessed easily and quickly through a simple API. All code is open access and freely available.

  14. Using Evidence-Based Interventions to Improve Cancer Screening in the National Breast and Cervical Cancer Early Detection Program.

    PubMed

    DeGroff, Amy; Carter, Aundrea; Kenney, Kristy; Myles, Zachary; Melillo, Stephanie; Royalty, Janet; Rice, Ketra; Gressard, Lindsay; Miller, Jacqueline W

    2016-01-01

    The National Breast and Cervical Cancer Early Detection Program (NBCCEDP) provides cancer screening to low-income, un-, and underinsured women through more than 11 000 primary care clinics. The program is well-positioned to work with health systems to implement evidence-based interventions (EBIs) to increase screening among all women. To collect baseline data on EBI use, evaluation of EBIs, and related training needs among NBCCEDP grantees. The Centers for Disease Control and Prevention conducted a Web-based survey in late 2013 among NBCCEDP grantees for the period July 2012 to June 2013. This was the first systematic assessment of EBIs among NBCCEDP grantees. The Centers for Disease Control and Prevention's NBCCEDP. Primarily program directors/coordinators for all 67 NBCCEDP grantees. Data captured were used to assess implementation of 5 EBIs, their evaluation, and related training needs. Frequencies and proportions were determined. Cluster analysis identified grantees with similar patterns of EBI use for NBCCEDP clients and providers. On average, 4.1 of 5 EBIs were implemented per grantee for NBCCEDP clients and providers. Four clusters were identified including "high overall EBI users," "high provider EBI users," "high EBI users with no provider assessment and feedback," and "high client EBI users." Only 1.8 EBIs were implemented, on average, with non-NBCCEDP clients and providers. Fewer than half (n = 32, 47.8%) of grantees conducted process or outcome evaluation of 1 or more EBIs. Overall, 47.6% of grantees reported high or medium training needs for client-oriented EBIs and 54.3% for provider-oriented EBIs. The NBCCEDP grantees are implementing EBIs extensively with clients and providers. Increased EBI use among non-NBCCEDP clients/providers is needed to extend the NBCCEDP's reach and impact. Grantee training and technical assistance is necessary across EBIs. In addition, grantees' use of process and outcome evaluation of EBI implementation must be increased to inform effective program implementation.

  15. The Conceptualization, Integration, and Support of Evidence-Based Interventions in the Schools

    ERIC Educational Resources Information Center

    Becker, Kimberly D.; Domitrovich, Celene E.

    2011-01-01

    The studies in this issue break the mold of the traditional stage model of the development and testing of evidence-based interventions (EBIs) within the confines of highly controlled studies (Onken, Blaine, & Battjes, 1997). Although this approach has merits, the need for EBIs in school settings has outpaced their deployment. The authors of these…

  16. Disruptive Innovations for Designing and Diffusing Evidence-based Interventions

    PubMed Central

    Rotheram-Borus, Mary Jane; Swendeman, Dallas; Chorpita, Bruce F.

    2013-01-01

    The numbers of evidence-based interventions (EBIs) have been growing exponentially, both therapeutic and prevention programs. Yet, EBIs have not been broadly adopted in the United States. In order for our EBI science to significantly reduce disease burden, we need to critically re-examine our scientific conventions and norms. Innovation may be spurred by re-examining the biomedical model for validating EBIs and the compartmentalization of EBIs as disease-specific, institutionally-based, counseling programs. The model of Disruptive Innovations suggests that we re-engineer EBIs based on their most robust features in order to reach more people in less time and at lower cost. Four new research agendas will be required to support disruptive innovations in EBI science: synthesize common elements across EBIs; experiment with new delivery formats (e.g., consumer controlled, self-directed, brief, paraprofessional, coaching, and technology and media strategies); adopt market strategies to promote and diffuse EBI science, knowledge, and products; and adopt continuous quality improvement as a research paradigm for systematically improving EBIs, based on ongoing data and feedback. EBI science can have more impact if it can better leverage what we know from existing EBIs in order to inspire, engage, inform, and support families and children to adopt and sustain healthy daily routines and lifestyles. PMID:22545596

  17. Developing Theory to Guide Building Practitioners’ Capacity to Implement Evidence-Based Interventions

    PubMed Central

    Leeman, Jennifer; Calancie, Larissa; Kegler, Michelle C.; Escoffery, Cam T.; Herrmann, Alison K.; Thatcher, Esther; Hartman, Marieke A.; Fernandez, Maria

    2017-01-01

    Public health and other community-based practitioners have access to a growing number of evidence-based interventions (EBIs), and yet EBIs continue to be underused. One reason for this underuse is that practitioners often lack the capacity (knowledge, skills, and motivation) to select, adapt, and implement EBIs. Training, technical assistance, and other capacity-building strategies can be effective at increasing EBI adoption and implementation. However, little is known about how to design capacity-building strategies or tailor them to differences in capacity required across varying EBIs and practice contexts. To address this need, we conducted a scoping study of frameworks and theories detailing variations in EBIs or practice contexts and how to tailor capacity-building to address those variations. Using an iterative process, we consolidated constructs and propositions across 24 frameworks and developed a beginning theory to describe salient variations in EBIs (complexity and uncertainty) and practice contexts (decision-making structure, general capacity to innovate, resource and values fit with EBI, and unity vs. polarization of stakeholder support). The theory also includes propositions for tailoring capacity-building strategies to address salient variations. To have wide-reaching and lasting impact, the dissemination of EBIs needs to be coupled with strategies that build practitioners’ capacity to adopt and implement a variety of EBIs across diverse practice contexts. PMID:26500080

  18. Developing Theory to Guide Building Practitioners' Capacity to Implement Evidence-Based Interventions.

    PubMed

    Leeman, Jennifer; Calancie, Larissa; Kegler, Michelle C; Escoffery, Cam T; Herrmann, Alison K; Thatcher, Esther; Hartman, Marieke A; Fernandez, Maria E

    2017-02-01

    Public health and other community-based practitioners have access to a growing number of evidence-based interventions (EBIs), and yet EBIs continue to be underused. One reason for this underuse is that practitioners often lack the capacity (knowledge, skills, and motivation) to select, adapt, and implement EBIs. Training, technical assistance, and other capacity-building strategies can be effective at increasing EBI adoption and implementation. However, little is known about how to design capacity-building strategies or tailor them to differences in capacity required across varying EBIs and practice contexts. To address this need, we conducted a scoping study of frameworks and theories detailing variations in EBIs or practice contexts and how to tailor capacity-building to address those variations. Using an iterative process, we consolidated constructs and propositions across 24 frameworks and developed a beginning theory to describe salient variations in EBIs (complexity and uncertainty) and practice contexts (decision-making structure, general capacity to innovate, resource and values fit with EBI, and unity vs. polarization of stakeholder support). The theory also includes propositions for tailoring capacity-building strategies to address salient variations. To have wide-reaching and lasting impact, the dissemination of EBIs needs to be coupled with strategies that build practitioners' capacity to adopt and implement a variety of EBIs across diverse practice contexts.

  19. Reactome diagram viewer: data structures and strategies to boost performance.

    PubMed

    Fabregat, Antonio; Sidiropoulos, Konstantinos; Viteri, Guilherme; Marin-Garcia, Pablo; Ping, Peipei; Stein, Lincoln; D'Eustachio, Peter; Hermjakob, Henning

    2018-04-01

    Reactome is a free, open-source, open-data, curated and peer-reviewed knowledgebase of biomolecular pathways. For web-based pathway visualization, Reactome uses a custom pathway diagram viewer that has been evolved over the past years. Here, we present comprehensive enhancements in usability and performance based on extensive usability testing sessions and technology developments, aiming to optimize the viewer towards the needs of the community. The pathway diagram viewer version 3 achieves consistently better performance, loading and rendering of 97% of the diagrams in Reactome in less than 1 s. Combining the multi-layer html5 canvas strategy with a space partitioning data structure minimizes CPU workload, enabling the introduction of new features that further enhance user experience. Through the use of highly optimized data structures and algorithms, Reactome has boosted the performance and usability of the new pathway diagram viewer, providing a robust, scalable and easy-to-integrate solution to pathway visualization. As graph-based visualization of complex data is a frequent challenge in bioinformatics, many of the individual strategies presented here are applicable to a wide range of web-based bioinformatics resources. Reactome is available online at: https://reactome.org. The diagram viewer is part of the Reactome pathway browser (https://reactome.org/PathwayBrowser/) and also available as a stand-alone widget at: https://reactome.org/dev/diagram/. The source code is freely available at: https://github.com/reactome-pwp/diagram. fabregat@ebi.ac.uk or hhe@ebi.ac.uk. Supplementary data are available at Bioinformatics online.

  20. The CARIBU EBIS control and synchronization system

    NASA Astrophysics Data System (ADS)

    Dickerson, Clayton; Peters, Christopher

    2015-01-01

    The Californium Rare Isotope Breeder Upgrade (CARIBU) Electron Beam Ion Source (EBIS) charge breeder has been built and tested. The bases of the CARIBU EBIS electrical system are four voltage platforms on which both DC and pulsed high voltage outputs are controlled. The high voltage output pulses are created with either a combination of a function generator and a high voltage amplifier, or two high voltage DC power supplies and a high voltage solid state switch. Proper synchronization of the pulsed voltages, fundamental to optimizing the charge breeding performance, is achieved with triggering from a digital delay pulse generator. The control system is based on National Instruments realtime controllers and LabVIEW software implementing Functional Global Variables (FGV) to store and access instrument parameters. Fiber optic converters enable network communication and triggering across the platforms.

  1. The EMBL-EBI bioinformatics web and programmatic tools framework.

    PubMed

    Li, Weizhong; Cowley, Andrew; Uludag, Mahmut; Gur, Tamer; McWilliam, Hamish; Squizzato, Silvano; Park, Young Mi; Buso, Nicola; Lopez, Rodrigo

    2015-07-01

    Since 2009 the EMBL-EBI Job Dispatcher framework has provided free access to a range of mainstream sequence analysis applications. These include sequence similarity search services (https://www.ebi.ac.uk/Tools/sss/) such as BLAST, FASTA and PSI-Search, multiple sequence alignment tools (https://www.ebi.ac.uk/Tools/msa/) such as Clustal Omega, MAFFT and T-Coffee, and other sequence analysis tools (https://www.ebi.ac.uk/Tools/pfa/) such as InterProScan. Through these services users can search mainstream sequence databases such as ENA, UniProt and Ensembl Genomes, utilising a uniform web interface or systematically through Web Services interfaces (https://www.ebi.ac.uk/Tools/webservices/) using common programming languages, and obtain enriched results with novel visualisations. Integration with EBI Search (https://www.ebi.ac.uk/ebisearch/) and the dbfetch retrieval service (https://www.ebi.ac.uk/Tools/dbfetch/) further expands the usefulness of the framework. New tools and updates such as NCBI BLAST+, InterProScan 5 and PfamScan, new categories such as RNA analysis tools (https://www.ebi.ac.uk/Tools/rna/), new databases such as ENA non-coding, WormBase ParaSite, Pfam and Rfam, and new workflow methods, together with the retirement of depreciated services, ensure that the framework remains relevant to today's biological community. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  2. Evaluation of the Effectiveness and Implementation of an Adapted Evidence-Based Mammography Intervention for African American Women

    PubMed Central

    Highfield, Linda; Hartman, Marieke A.; Bartholomew, L. Kay; Balihe, Philomene; Ausborn, Valerie A.

    2015-01-01

    Breast cancer mortality disparities continue, particularly for uninsured and minority women. A number of effective evidence-based interventions (EBIs) exist for addressing barriers to mammography screening; however, their uptake and use in community has been limited. Few cancer-specific studies have evaluated adapted EBIs in new contexts, and fewer still have considered implementation. This study sought to (1) evaluate the effectiveness of an adapted mammography EBI in improving appointment keeping in African American women and (2) describe processes of implementation in a new practice setting. We used the type 1 hybrid design to test effectiveness and implementation using a quasi-experimental design. Logistic regression and intent-to-treat analysis were used to evaluate mammography appointment attendance. The no-show rate was 44% (comparison) versus 19% (intervention). The adjusted odds of a woman in the intervention group attending her appointment were 3.88 (p < 0.001). The adjusted odds of a woman attending her appointment in the intent-to-treat analysis were 2.31 (p < 0.05). Adapted EBI effectiveness was 3.88 (adjusted OR) versus 2.10 (OR) for the original program, indicating enhanced program effect. A number of implementation barriers and facilitators were identified. Our findings support previous studies noting that sequentially measuring EBI efficacy and effectiveness, followed by implementation, may be missing important contextual information. PMID:26504790

  3. Oxysterol-EBI2 signaling in immune regulation and viral infection.

    PubMed

    Daugvilaite, Viktorija; Arfelt, Kristine Niss; Benned-Jensen, Tau; Sailer, Andreas W; Rosenkilde, Mette M

    2014-07-01

    The seven transmembrane G protein-coupled receptor Epstein-Barr virus (EBV) induced gene 2 (EBI2; also known as GPR183) was identified in 1993 on the basis of its substantial upregulation in EBV-infected cells. It is primarily expressed in lymphoid cells; most abundantly in B cells. EBI2 is central for the positioning of B cells within the lymphoid organs, a process that is regulated in part by a chemotactic gradient formed by the endogenous lipid agonists, and in part by a fine-tuned regulation of EBI2 cell surface expression. The most potent endogenous EBI2 agonist is 7α, 25-dihydroxyxcholesterol (7α,25-OHC), yet many structurally related oxysterols can bind to an EBI2 pocket that is defined by the upper parts of the transmembrane helices and extracellular receptor regions. EBI2 signals via Gαi, as well as via G protein-independent pathways like β-arrestin recruitment. The concerted action of these pathways leads to cell migration. By genetically interfering with its up- and downregulation, EBI2 was also recently shown to induce cell proliferation, an action that could be inhibited by small molecule antagonists. Here, we focus on the oxysterol-EBI2 axis in immune control, including its role in the EBV life cycle. We also summarize the structural and functional properties of EBI2 interaction with oxysterol agonists and small molecule antagonists and discuss EBI2 as therapeutic target for diseases of the immune system. © 2014 The Authors. European Journal of Immunology published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Disruptive innovations for designing and diffusing evidence-based interventions.

    PubMed

    Rotheram-Borus, Mary Jane; Swendeman, Dallas; Chorpita, Bruce F

    2012-09-01

    Evidence-based therapeutic and preventive intervention programs (EBIs) have been growing exponentially. Yet EBIs have not been broadly adopted in the United States. In order for our EBI science to significantly reduce disease burden, we need to critically reexamine our scientific conventions and norms. Innovation may be spurred by reexamining the traditional biomedical model for validating, implementing, and diffusing EBI products and science. The model of disruptive innovations suggests that we reengineer EBIs on the basis of their most robust features in order to serve more people in less time and at lower cost. A disruptive innovation provides a simpler and less expensive alternative that meets the essential needs for the majority of consumers and is more accessible, scalable, replicable, and sustainable. Examples of disruptive innovations from other fields include minute clinics embedded in retail chain drug stores, $2 generic eyeglasses, automated teller machines, and telemedicine. Four new research approaches will be required to support disruptive innovations in EBI science: synthesize common elements across EBIs; experiment with new delivery formats (e.g., consumer controlled, self-directed, brief, paraprofessional, coaching, and technology and media strategies); adopt market strategies to promote and diffuse EBI science, knowledge, and products; and adopt continuous quality improvement as a research paradigm for systematically improving EBIs, based on ongoing monitoring data and feedback. EBI science can have more impact if it can better leverage what we know from existing EBIs in order to inspire, engage, inform, and support families and children to adopt and sustain healthy daily routines and lifestyles. (PsycINFO Database Record (c) 2012 APA, all rights reserved).

  5. DNA sequence chromatogram browsing using JAVA and CORBA.

    PubMed

    Parsons, J D; Buehler, E; Hillier, L

    1999-03-01

    DNA sequence chromatograms (traces) are the primary data source for all large-scale genomic and expressed sequence tags (ESTs) sequencing projects. Access to the sequencing trace assists many later analyses, for example contig assembly and polymorphism detection, but obtaining and using traces is problematic. Traces are not collected and published centrally, they are much larger than the base calls derived from them, and viewing them requires the interactivity of a local graphical client with local data. To provide efficient global access to DNA traces, we developed a client/server system based on flexible Java components integrated into other applications including an applet for use in a WWW browser and a stand-alone trace viewer. Client/server interaction is facilitated by CORBA middleware which provides a well-defined interface, a naming service, and location independence. [The software is packaged as a Jar file available from the following URL: http://www.ebi.ac.uk/jparsons. Links to working examples of the trace viewers can be found at http://corba.ebi.ac.uk/EST. All the Washington University mouse EST traces are available for browsing at the same URL.

  6. Off-line commissioning of EBIS and plans for its integration into ATLAS and CARIBU.

    PubMed

    Ostroumov, P N; Barcikowski, A; Dickerson, C A; Mustapha, B; Perry, A; Sharamentov, S I; Vondrasek, R C; Zinkann, G

    2016-02-01

    An Electron Beam Ion Source Charge Breeder (EBIS-CB) has been developed at Argonne to breed radioactive beams from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) facility at Argonne Tandem Linac Accelerator System (ATLAS). The EBIS-CB will replace the existing ECR charge breeder to increase the intensity and significantly improve the purity of reaccelerated radioactive ion beams. The CARIBU EBIS-CB has been successfully commissioned offline with an external singly charged cesium ion source. The performance of the EBIS fully meets the specifications to breed rare isotope beams delivered from CARIBU. The EBIS is being relocated and integrated into ATLAS and CARIBU. A long electrostatic beam transport system including two 180° bends in the vertical plane has been designed. The commissioning of the EBIS and the beam transport system in their permanent location will start at the end of this year.

  7. Off-line commissioning of EBIS and plans for its integration into ATLAS and CARIBU

    NASA Astrophysics Data System (ADS)

    Ostroumov, P. N.; Barcikowski, A.; Dickerson, C. A.; Mustapha, B.; Perry, A.; Sharamentov, S. I.; Vondrasek, R. C.; Zinkann, G.

    2016-02-01

    An Electron Beam Ion Source Charge Breeder (EBIS-CB) has been developed at Argonne to breed radioactive beams from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) facility at Argonne Tandem Linac Accelerator System (ATLAS). The EBIS-CB will replace the existing ECR charge breeder to increase the intensity and significantly improve the purity of reaccelerated radioactive ion beams. The CARIBU EBIS-CB has been successfully commissioned offline with an external singly charged cesium ion source. The performance of the EBIS fully meets the specifications to breed rare isotope beams delivered from CARIBU. The EBIS is being relocated and integrated into ATLAS and CARIBU. A long electrostatic beam transport system including two 180° bends in the vertical plane has been designed. The commissioning of the EBIS and the beam transport system in their permanent location will start at the end of this year.

  8. OntoCAT -- simple ontology search and integration in Java, R and REST/JavaScript

    PubMed Central

    2011-01-01

    Background Ontologies have become an essential asset in the bioinformatics toolbox and a number of ontology access resources are now available, for example, the EBI Ontology Lookup Service (OLS) and the NCBO BioPortal. However, these resources differ substantially in mode, ease of access, and ontology content. This makes it relatively difficult to access each ontology source separately, map their contents to research data, and much of this effort is being replicated across different research groups. Results OntoCAT provides a seamless programming interface to query heterogeneous ontology resources including OLS and BioPortal, as well as user-specified local OWL and OBO files. Each resource is wrapped behind easy to learn Java, Bioconductor/R and REST web service commands enabling reuse and integration of ontology software efforts despite variation in technologies. It is also available as a stand-alone MOLGENIS database and a Google App Engine application. Conclusions OntoCAT provides a robust, configurable solution for accessing ontology terms specified locally and from remote services, is available as a stand-alone tool and has been tested thoroughly in the ArrayExpress, MOLGENIS, EFO and Gen2Phen phenotype use cases. Availability http://www.ontocat.org PMID:21619703

  9. OntoCAT--simple ontology search and integration in Java, R and REST/JavaScript.

    PubMed

    Adamusiak, Tomasz; Burdett, Tony; Kurbatova, Natalja; Joeri van der Velde, K; Abeygunawardena, Niran; Antonakaki, Despoina; Kapushesky, Misha; Parkinson, Helen; Swertz, Morris A

    2011-05-29

    Ontologies have become an essential asset in the bioinformatics toolbox and a number of ontology access resources are now available, for example, the EBI Ontology Lookup Service (OLS) and the NCBO BioPortal. However, these resources differ substantially in mode, ease of access, and ontology content. This makes it relatively difficult to access each ontology source separately, map their contents to research data, and much of this effort is being replicated across different research groups. OntoCAT provides a seamless programming interface to query heterogeneous ontology resources including OLS and BioPortal, as well as user-specified local OWL and OBO files. Each resource is wrapped behind easy to learn Java, Bioconductor/R and REST web service commands enabling reuse and integration of ontology software efforts despite variation in technologies. It is also available as a stand-alone MOLGENIS database and a Google App Engine application. OntoCAT provides a robust, configurable solution for accessing ontology terms specified locally and from remote services, is available as a stand-alone tool and has been tested thoroughly in the ArrayExpress, MOLGENIS, EFO and Gen2Phen phenotype use cases. http://www.ontocat.org.

  10. The CARIBU EBIS control and synchronization system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dickerson, Clayton, E-mail: cdickerson@anl.gov; Peters, Christopher, E-mail: cdickerson@anl.gov

    2015-01-09

    The Californium Rare Isotope Breeder Upgrade (CARIBU) Electron Beam Ion Source (EBIS) charge breeder has been built and tested. The bases of the CARIBU EBIS electrical system are four voltage platforms on which both DC and pulsed high voltage outputs are controlled. The high voltage output pulses are created with either a combination of a function generator and a high voltage amplifier, or two high voltage DC power supplies and a high voltage solid state switch. Proper synchronization of the pulsed voltages, fundamental to optimizing the charge breeding performance, is achieved with triggering from a digital delay pulse generator. Themore » control system is based on National Instruments realtime controllers and LabVIEW software implementing Functional Global Variables (FGV) to store and access instrument parameters. Fiber optic converters enable network communication and triggering across the platforms.« less

  11. The EBI Search engine: providing search and retrieval functionality for biological data from EMBL-EBI.

    PubMed

    Squizzato, Silvano; Park, Young Mi; Buso, Nicola; Gur, Tamer; Cowley, Andrew; Li, Weizhong; Uludag, Mahmut; Pundir, Sangya; Cham, Jennifer A; McWilliam, Hamish; Lopez, Rodrigo

    2015-07-01

    The European Bioinformatics Institute (EMBL-EBI-https://www.ebi.ac.uk) provides free and unrestricted access to data across all major areas of biology and biomedicine. Searching and extracting knowledge across these domains requires a fast and scalable solution that addresses the requirements of domain experts as well as casual users. We present the EBI Search engine, referred to here as 'EBI Search', an easy-to-use fast text search and indexing system with powerful data navigation and retrieval capabilities. API integration provides access to analytical tools, allowing users to further investigate the results of their search. The interconnectivity that exists between data resources at EMBL-EBI provides easy, quick and precise navigation and a better understanding of the relationship between different data types including sequences, genes, gene products, proteins, protein domains, protein families, enzymes and macromolecular structures, together with relevant life science literature. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  12. The EBI SRS server-new features.

    PubMed

    Zdobnov, Evgeny M; Lopez, Rodrigo; Apweiler, Rolf; Etzold, Thure

    2002-08-01

    Here we report on recent developments at the EBI SRS server (http://srs.ebi.ac.uk). SRS has become an integration system for both data retrieval and sequence analysis applications. The EBI SRS server is a primary gateway to major databases in the field of molecular biology produced and supported at EBI as well as European public access point to the MEDLINE database provided by US National Library of Medicine (NLM). It is a reference server for latest developments in data and application integration. The new additions include: concept of virtual databases, integration of XML databases like the Integrated Resource of Protein Domains and Functional Sites (InterPro), Gene Ontology (GO), MEDLINE, Metabolic pathways, etc., user friendly data representation in 'Nice views', SRSQuickSearch bookmarklets. SRS6 is a licensed product of LION Bioscience AG freely available for academics. The EBI SRS server (http://srs.ebi.ac.uk) is a free central resource for molecular biology data as well as a reference server for the latest developments in data integration.

  13. The REX-ISOLDE charge breeder as an operational machine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wenander, F.; Delahaye, P.; Scrivens, R.

    2006-03-15

    The charge breeding system of radioactive beam experiment at ISOLDE (REX-ISOLDE), consisting of a large Penning trap in combination with an electron-beam ion source (EBIS), is now a mature concept after having delivered radioactive beams for postacceleration to a number of experiments for three years. The system, preparing ions prior to injection into a compact linear accelerator, has shown to be versatile in terms of the ion species and energies that can be delivered. During the experimental periods 2004 and 2005 a significant part of the ISOLDE beam time was dedicated to REX-ISOLDE experiments. Ion masses in the range betweenmore » A=7 and 153 have been handled with record efficiencies. High-intensity as well as very-short-lived isotope beams were proven to be feasible. Continuous injection into the EBIS has also been successfully tested. Two means of suppressing unwanted beam contaminations were tested and are now in use. In addition, the experience gained from the trap-EBIS concept from a machine operational point of view will be discussed and the limitations described.« less

  14. ICFA Beam Dynamics Newsletter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikin, A.

    2017-11-21

    Electron beam ion sources technology made significant progress since 1968 when this method of producing highly charged ions in a potential trap within electron beam was proposed by E. Donets. Better understanding of physical processes in EBIS, technological advances and better simulation tools determined significant progress in key EBIS parameters: electron beam current and current density, ion trap capacity, attainable charge states. Greatly increased the scope of EBIS and EBIT applications. An attempt is made to compile some of EBIS engineering problems and solutions and to demonstrate a present stage of understanding the processes and approaches to build a bettermore » EBIS.« less

  15. Mixed-method study of a conceptual model of evidence-based intervention sustainment across multiple public-sector service settings.

    PubMed

    Aarons, Gregory A; Green, Amy E; Willging, Cathleen E; Ehrhart, Mark G; Roesch, Scott C; Hecht, Debra B; Chaffin, Mark J

    2014-12-10

    This study examines sustainment of an EBI implemented in 11 United States service systems across two states, and delivered in 87 counties. The aims are to 1) determine the impact of state and county policies and contracting on EBI provision and sustainment; 2) investigate the role of public, private, and academic relationships and collaboration in long-term EBI sustainment; 3) assess organizational and provider factors that affect EBI reach/penetration, fidelity, and organizational sustainment climate; and 4) integrate findings through a collaborative process involving the investigative team, consultants, and system and community-based organization (CBO) stakeholders in order to further develop and refine a conceptual model of sustainment to guide future research and provide a resource for service systems to prepare for sustainment as the ultimate goal of the implementation process. A mixed-method prospective and retrospective design will be used. Semi-structured individual and group interviews will be used to collect information regarding influences on EBI sustainment including policies, attitudes, and practices; organizational factors and external policies affecting model implementation; involvement of or collaboration with other stakeholders; and outer- and inner-contextual supports that facilitate ongoing EBI sustainment. Document review (e.g., legislation, executive orders, regulations, monitoring data, annual reports, agendas and meeting minutes) will be used to examine the roles of state, county, and local policies in EBI sustainment. Quantitative measures will be collected via administrative data and web surveys to assess EBI reach/penetration, staff turnover, EBI model fidelity, organizational culture and climate, work attitudes, implementation leadership, sustainment climate, attitudes toward EBIs, program sustainment, and level of institutionalization. Hierarchical linear modeling will be used for quantitative analyses. Qualitative analyses will be tailored to each of the qualitative methods (e.g., document review, interviews). Qualitative and quantitative approaches will be integrated through an inclusive process that values stakeholder perspectives. The study of sustainment is critical to capitalizing on and benefiting from the time and fiscal investments in EBI implementation. Sustainment is also critical to realizing broad public health impact of EBI implementation. The present study takes a comprehensive mixed-method approach to understanding sustainment and refining a conceptual model of sustainment.

  16. Measurement properties of a novel survey to assess stages of organizational readiness for evidence-based interventions in community chronic disease prevention settings

    PubMed Central

    2012-01-01

    Background There is a great deal of variation in the existing capacity of primary prevention programs and policies addressing chronic disease to deliver evidence-based interventions (EBIs). In order to develop and evaluate implementation strategies that are tailored to the appropriate level of capacity, there is a need for an easy-to-administer tool to stage organizational readiness for EBIs. Methods Based on theoretical frameworks, including Rogers’ Diffusion of Innovations, we developed a survey instrument to measure four domains representing stages of readiness for EBI: awareness, adoption, implementation, and maintenance. A separate scale representing organizational climate as a potential mediator of readiness for EBIs was also included in the survey. Twenty-three questions comprised the four domains, with four to nine items each, using a seven-point response scale. Representatives from obesity, asthma, diabetes, and tobacco prevention programs serving diverse populations in the United States were surveyed (N = 243); test-retest reliability was assessed with 92 respondents. Results Confirmatory factor analysis (CFA) was used to test and refine readiness scales. Test-retest reliability of the readiness scales, as measured by intraclass correlation, ranged from 0.47–0.71. CFA found good fit for the five-item adoption and implementation scales and resulted in revisions of the awareness and maintenance scales. The awareness scale was split into two two-item scales, representing community and agency awareness. The maintenance scale was split into five- and four-item scales, representing infrastructural maintenance and evaluation maintenance, respectively. Internal reliability of scales (Cronbach’s α) ranged from 0.66–0.78. The model for the final revised scales approached good fit, with most factor loadings >0.6 and all >0.4. Conclusions The lack of adequate measurement tools hinders progress in dissemination and implementation research. These preliminary results help fill this gap by describing the reliability and measurement properties of a theory-based tool; the short, user-friendly instrument may be useful to researchers and practitioners seeking to assess organizational readiness for EBIs across a variety of chronic disease prevention programs and settings. PMID:22800294

  17. Measurement properties of a novel survey to assess stages of organizational readiness for evidence-based interventions in community chronic disease prevention settings.

    PubMed

    Stamatakis, Katherine A; McQueen, Amy; Filler, Carl; Boland, Elizabeth; Dreisinger, Mariah; Brownson, Ross C; Luke, Douglas A

    2012-07-16

    There is a great deal of variation in the existing capacity of primary prevention programs and policies addressing chronic disease to deliver evidence-based interventions (EBIs). In order to develop and evaluate implementation strategies that are tailored to the appropriate level of capacity, there is a need for an easy-to-administer tool to stage organizational readiness for EBIs. Based on theoretical frameworks, including Rogers' Diffusion of Innovations, we developed a survey instrument to measure four domains representing stages of readiness for EBI: awareness, adoption, implementation, and maintenance. A separate scale representing organizational climate as a potential mediator of readiness for EBIs was also included in the survey. Twenty-three questions comprised the four domains, with four to nine items each, using a seven-point response scale. Representatives from obesity, asthma, diabetes, and tobacco prevention programs serving diverse populations in the United States were surveyed (N=243); test-retest reliability was assessed with 92 respondents. Confirmatory factor analysis (CFA) was used to test and refine readiness scales. Test-retest reliability of the readiness scales, as measured by intraclass correlation, ranged from 0.47-0.71. CFA found good fit for the five-item adoption and implementation scales and resulted in revisions of the awareness and maintenance scales. The awareness scale was split into two two-item scales, representing community and agency awareness. The maintenance scale was split into five- and four-item scales, representing infrastructural maintenance and evaluation maintenance, respectively. Internal reliability of scales (Cronbach's α) ranged from 0.66-0.78. The model for the final revised scales approached good fit, with most factor loadings >0.6 and all >0.4. The lack of adequate measurement tools hinders progress in dissemination and implementation research. These preliminary results help fill this gap by describing the reliability and measurement properties of a theory-based tool; the short, user-friendly instrument may be useful to researchers and practitioners seeking to assess organizational readiness for EBIs across a variety of chronic disease prevention programs and settings.

  18. Improving the delivery of brief interventions for heavy drinking in primary health care: outcome results of the Optimizing Delivery of Health Care Intervention (ODHIN) five-country cluster randomized factorial trial.

    PubMed

    Anderson, Peter; Bendtsen, Preben; Spak, Fredrik; Reynolds, Jillian; Drummond, Colin; Segura, Lidia; Keurhorst, Myrna N; Palacio-Vieira, Jorge; Wojnar, Marcin; Parkinson, Kathryn; Colom, Joan; Kłoda, Karolina; Deluca, Paolo; Baena, Begoña; Newbury-Birch, Dorothy; Wallace, Paul; Heinen, Maud; Wolstenholme, Amy; van Steenkiste, Ben; Mierzecki, Artur; Okulicz-Kozaryn, Katarzyna; Ronda, Gaby; Kaner, Eileen; Laurant, Miranda G H; Coulton, Simon; Gual, Toni

    2016-11-01

    To test if training and support, financial reimbursement and option of referring screen-positive patients to an internet-based method of giving advice (eBI) can increase primary health-care providers' delivery of Alcohol Use Disorders Identification Test (AUDIT)-C-based screening and advice to heavy drinkers. Cluster randomized factorial trial with 12-week implementation and measurement period. Primary health-care units (PHCU) in different locations throughout Catalonia, England, the Netherlands, Poland and Sweden. A total of 120 PHCU, 24 in each of Catalonia, England, the Netherlands, Poland and Sweden. PHCUs were randomized to one of eight groups: care as usual, training and support (TS), financial reimbursement (FR) and eBI; paired combinations of TS, FR and eBI, and all of FR, TS and eBI. The primary outcome measure was the proportion of eligible adult (age 18+ years) patients screened during a 12-week implementation period. Secondary outcome measures were proportion of screen-positive patients advised; and proportion of consulting adult patients given an intervention (screening and advice to screen-positives) during the same 12-week implementation period. During a 4-week baseline measurement period, the proportion of consulting adult patients who were screened for their alcohol consumption was 0.059 per PHCU (95% CI 0.034 to 0.084). Based on the factorial design, the ratio of the logged proportion screened during the 12-week implementation period was 1.48 (95% CI = 1.13-1.95) in PHCU that received TS versus PHCU that did not receive TS; for FR, the ratio was 2.00 (95% CI = 1.56-2.56). The option of referral to eBI did not lead to a higher proportion of patients screened. The ratio for TS plus FR was 2.34 (95% CI = 1.77-3.10), and the ratio for TS plus FR plus eBI was1.68 (95% CI = 1.11-2.53). Providing primary health-care units with training, support and financial reimbursement for delivering Alcohol Use Disorders Identification Test-C-based screening and advice to heavy drinkers increases screening for alcohol consumption. Providing primary health-care units with the option of referring screen-positive patients to an internet-based method of giving advice does not appear to increase screening for alcohol consumption. © 2016 Society for the Study of Addiction.

  19. Electron beam simulation from gun to collector: Towards a complete solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mertzig, R., E-mail: robert.mertzig@cern.ch; Shornikov, A., E-mail: robert.mertzig@cern.ch; Wenander, F.

    An electron-beam simulation technique for high-resolution complete EBIS/T modelling is presented. The technique was benchmarked on the high compression HEC{sup 2} test-stand with an electron beam current, current density and energy of 10 A, 10 kA/cm{sup 2} and 49.2 keV, and on the immersed electron beam at REXEBIS for electron beam characteristics of 0.4 A, 200 A/cm{sup 2} and 4.5 keV. In both Brillouin-like and immersed beams the electron-beam radius varies from several millimeters at the gun, through some hundreds of micrometers in the ionization region to a few centimeters at the collector over a total length of several meters.more » We report on our approach for finding optimal meshing parameters, based on the local beam properties such as magnetic field-strength, electron energy and beam radius. This approach combined with dividing the problem domain into sub-domains, and subsequent splicing of the local solutions allowed us to simulate the beam propagation in EBISes from the gun to the collector using a conventional PC in about 24–36 h. Brillouin-like electron beams propagated through the complete EBIS were used to analyze the beam behavior within the collector region. We checked whether elastically reflected paraxial electrons from a Brillouin-like beam will escape from the collector region and add to the loss current. We have also studied the power deposition profiles as function of applied potentials using two electrode geometries for a Brillouin-like beam including the effects of backscattered electrons.« less

  20. The dynamics of de-adoption: a case study of policy change, de-adoption, and replacement of an evidence-based HIV intervention.

    PubMed

    McKay, Virginia R; Margaret Dolcini, M; Hoffer, Lee D

    2017-12-01

    Evidence-based intervention (EBI) de-adoption and its influence on public health organizations are largely unexplored within public health implementation research. However, a recent shift in support for HIV prevention EBIs by the Centers for Disease Control and Prevention provides an opportunity to explore EBI de-adoption. The current mixed-method study examines EBI de-adoption and the subsequent impact on a community-based organization (CBO) dedicated to HIV prevention. We conducted a case study with a CBO implementing RESPECT, an HIV prevention EBI, over 5 years (2010-2014), but then de-adopted the intervention. We collected archival data documenting RESPECT implementation and conducted two semi-structured interviews with RESPECT staff (N = 5). Using Fixsen and colleagues' implementation framework, we developed a narrative of RESPECT implementation, delivery, and de-adoption and a thematic analysis to understand additional consequences of RESPECT de-adoption. Discontinuation of RESPECT activities unfolded in a process over time, requiring effort by RESPECT staff. RESPECT de-adoption had wide-reaching influences on individual staff, interactions between the staff and the community, the agency overall, and for implementation of future EBIs. We propose a revision of the implementation framework, incorporating EBI de-adoption as a phase of the implementation cycle. Furthermore, EBI de-adoption may have important, unintended consequences and can inform future HIV prevention strategies and guide research focusing on EBI de-adoption.

  1. Low dose elective brain irradiation in small cell carcinoma of the lung

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beiler, D.D.; Kane, R.C.; Bernath, A.M.

    Elective brain irradiation (EBI) in a dosage of 3000 rad (midplane) in 2 weeks (nominal standard dose (NSD) = 1314 ret) has proven highly effective in preventing initial brain relapse in small cell lung carcinoma. However, the optimal radiation dose for EBI is unknown. 55 patients (31 with regional disease, 24 with extensive disease) without brain metastases were treated with a 4 drug chemotherapy program, (lomustine (CCNU), methotrexate, cyclophosphamide, vincristine) plus radiotherapy (R.T.), 3000 rad in 2 weeks to the primary chest lesion and were randomized to EBI or a control group. The EBI consisted of 2400 rad whole brain,more » midplane, in 8 fractions, 10 days (NSD = 1130 ret) given at the same time as the R.T. to the primary (3 weeks post-initial chemotherapy). Though all 54 evaluable patients received CCNU 50 mg/M/sup 2/q. 6 weeks, there were 5 initial brain relapses among 31 control patients (16%) vs none in the 23 EBI patients. The time at risk for recurrence was similar in the two groups, i.e. 31 weeks median in the EBI and 32 weeks in the no-EBI patients. Brain relapses occurred in 2/17 with limited disease and 3/14 with extensive disease. It appears that 2400 rad in 8 fractions is as effective for EBI as larger doses. Toxicity was limited to alopecia. Survival was not significantly affected by EBI, though there is a suggestion of improvement in the regional group.« less

  2. Intervention Mapping to Adapt Evidence-Based Interventions for Use in Practice: Increasing Mammography among African American Women.

    PubMed

    Highfield, Linda; Hartman, Marieke A; Mullen, Patricia Dolan; Rodriguez, Serena A; Fernandez, Maria E; Bartholomew, L Kay

    2015-01-01

    This paper describes and demonstrates the use of the systematic planning process, Intervention Mapping, to adapt an evidence-based public health intervention (EBI). We used a simplified version of Intervention Mapping (IM Adapt) to increase an intervention's fit with a new setting and population. IM Adapt guides researchers and practitioners in selecting an EBI, making decisions about whether and what to adapt, and executing the adaptation while guarding the EBI's essential elements (those responsible for effectiveness). We present a case study of a project in which we used IM Adapt to find, adapt, implement, and evaluate an EBI to improve mammography adherence for African American women in a new practice setting in Houston, Texas. IM Adapt includes the following (1) assess needs and organizational capacity; (2) find EBIs; (3) plan adaptations based on fit assessments; (4) make adaptations; (5) plan for implementation; and (6) plan for evaluation of the adapted EBI. The case study shows an example of how public health researchers and practitioners can use the tool to make it easier to find and use EBIs, thus encouraging greater uptake. IM Adapt adds to existing dissemination and adaptation models by providing detailed guidance on how to decide on effective adaptation, while maintaining the essential elements of the EBI.

  3. Intervention Mapping to Adapt Evidence-Based Interventions for Use in Practice: Increasing Mammography among African American Women

    PubMed Central

    Highfield, Linda; Hartman, Marieke A.; Mullen, Patricia Dolan; Fernandez, Maria E.; Bartholomew, L. Kay

    2015-01-01

    This paper describes and demonstrates the use of the systematic planning process, Intervention Mapping, to adapt an evidence-based public health intervention (EBI). We used a simplified version of Intervention Mapping (IM Adapt) to increase an intervention's fit with a new setting and population. IM Adapt guides researchers and practitioners in selecting an EBI, making decisions about whether and what to adapt, and executing the adaptation while guarding the EBI's essential elements (those responsible for effectiveness). We present a case study of a project in which we used IM Adapt to find, adapt, implement, and evaluate an EBI to improve mammography adherence for African American women in a new practice setting in Houston, Texas. IM Adapt includes the following (1) assess needs and organizational capacity; (2) find EBIs; (3) plan adaptations based on fit assessments; (4) make adaptations; (5) plan for implementation; and (6) plan for evaluation of the adapted EBI. The case study shows an example of how public health researchers and practitioners can use the tool to make it easier to find and use EBIs, thus encouraging greater uptake. IM Adapt adds to existing dissemination and adaptation models by providing detailed guidance on how to decide on effective adaptation, while maintaining the essential elements of the EBI. PMID:26587531

  4. A wireless multi-channel bioimpedance measurement system for personalized healthcare and lifestyle.

    PubMed

    Ramos, Javier; Ausín, José Luis; Lorido, Antonio Manuel; Redondo, Francisco; Duque-Carrillo, Juan Francisco

    2013-01-01

    Miniaturized, noninvasive, wearable sensors constitute a fundamental prerequisite for pervasive, predictive, and preventive healthcare systems. In this sense, this paper presents the design, realization, and evaluation of a wireless multi-channel measurement system based on a cost-effective high-performance integrated circuit for electrical bioimpedance (EBI) measurements in the frequency range from 1 kHz to 1 MHz. The resulting on-chip spectrometer provides high measuring EBI capabilities and together with a low-cost, commercially available radio frequency transceiver device. It provides reliable wireless communication, constitutes the basic node to build EBI wireless sensor networks (EBI-WSNs). The proposed EBI-WSN behaves as a high-performance wireless multi-channel EBI spectrometer, where the number of channels is completely scalable and independently configurable to satisfy specific measurement requirements of each individual. A prototype of the EBI node leads to a very small printed circuit board of approximately 8 cm2 including chip-antenna, which can operate several years on one 3-V coin cell battery and make it suitable for long-term preventive healthcare monitoring.

  5. The EBI search engine: EBI search as a service—making biological data accessible for all

    PubMed Central

    Park, Young M.; Squizzato, Silvano; Buso, Nicola; Gur, Tamer

    2017-01-01

    Abstract We present an update of the EBI Search engine, an easy-to-use fast text search and indexing system with powerful data navigation and retrieval capabilities. The interconnectivity that exists between data resources at EMBL–EBI provides easy, quick and precise navigation and a better understanding of the relationship between different data types that include nucleotide and protein sequences, genes, gene products, proteins, protein domains, protein families, enzymes and macromolecular structures, as well as the life science literature. EBI Search provides a powerful RESTful API that enables its integration into third-party portals, thus providing ‘Search as a Service’ capabilities, which are the main topic of this article. PMID:28472374

  6. Colorectal Cancer Control Program Grantees’ Use of Evidence-Based Interventions

    PubMed Central

    Hannon, Peggy A.; Maxwell, Annette E.; Escoffery, Cam; Vu, Thuy; Kohn, Marlana; Leeman, Jennifer; Carvalho, Michelle L.; Pfeiffer, Debbie J.; Dwyer, Andrea; Fernandez, Maria E.; Vernon, Sally W.; Liang, Lily; DeGroff, Amy

    2015-01-01

    Background Colorectal cancer (CRC) screening is recommended for adults aged 50–75 years, yet screening rates are low, especially among the uninsured. The CDC initiated the Colorectal Cancer Control Program (CRCCP) in 2009 with the goal of increasing CRC screening rates to 80% by 2014. A total of 29 grantees (states and tribal organizations) receive CRCCP funding to (1) screen uninsured adults and (2) promote CRC screening at the population level. Purpose CRCCP encourages grantees to use one or more of five evidence-based interventions (EBIs) recommended by the Guide to Community Preventive Services. The purpose of the study was to evaluate grantees’ EBI use. Methods A web-based survey was conducted in 2011 measuring grantees’ use of CRC screening EBIs and identifying their implementation partners. Data were analyzed in 2012. Results Twenty-eight grantees (97%) completed the survey. Most respondents (96%) used small media. Fewer used client reminders (75%); reduction of structural barriers (50%); provider reminders (32%); or provider assessment and feedback (50%). Provider-oriented EBIs were rated as harder to implement than client-oriented EBIs. Grantees partnered with several types of organizations to implement EBIs, many with county- or state-wide reach. Conclusions Almost all grantees implement EBIs to promote CRC screening, but the EBIs that may have the greatest impact with CRC screening are implemented by fewer grantees in the first 2 years of the CRCCP. PMID:24139779

  7. The dynamic influence of human resources on evidence-based intervention sustainability and population outcomes: an agent-based modeling approach.

    PubMed

    McKay, Virginia R; Hoffer, Lee D; Combs, Todd B; Margaret Dolcini, M

    2018-06-05

    Sustaining evidence-based interventions (EBIs) is an ongoing challenge for dissemination and implementation science in public health and social services. Characterizing the relationship among human resource capacity within an agency and subsequent population outcomes is an important step to improving our understanding of how EBIs are sustained. Although human resource capacity and population outcomes are theoretically related, examining them over time within real-world experiments is difficult. Simulation approaches, especially agent-based models, offer advantages that complement existing methods. We used an agent-based model to examine the relationships among human resources, EBI delivery, and population outcomes by simulating provision of an EBI through a hypothetical agency and its staff. We used data from existing studies examining a widely implemented HIV prevention intervention to inform simulation design, calibration, and validity. Once we developed a baseline model, we used the model as a simulated laboratory by systematically varying three human resource variables: the number of staff positions, the staff turnover rate, and timing in training. We tracked the subsequent influence on EBI delivery and the level of population risk over time to describe the overall and dynamic relationships among these variables. Higher overall levels of human resource capacity at an agency (more positions) led to more extensive EBI delivery over time and lowered population risk earlier in time. In simulations representing the typical human resource investments, substantial influences on population risk were visible after approximately 2 years and peaked around 4 years. Human resources, especially staff positions, have an important impact on EBI sustainability and ultimately population health. A minimum level of human resources based on the context (e.g., size of the initial population and characteristics of the EBI) is likely needed for an EBI to have a meaningful impact on population outcomes. Furthermore, this model demonstrates how ABMs may be leveraged to inform research design and assess the impact of EBI sustainability in practice.

  8. Converting the Conducting Behavior of Graphene Oxides from n-Type to p-Type via Electron-Beam Irradiation.

    PubMed

    Mirzaei, Ali; Kwon, Yong Jung; Wu, Ping; Kim, Sang Sub; Kim, Hyoun Woo

    2018-02-28

    We studied the effects of electron-beam irradiation (EBI) on the structural and gas-sensing properties of graphene oxide (GO). To understand the effects of EBI on the structure and gas-sensing behavior of irradiated GO, the treated GO was compared with nonirradiated GO. Characterization results indicated an enhancement in the number of oxygen functional groups that occurs with EBI exposure at 100 kGy and then decreases with doses in the range of 100-500 kGy. Data from Raman spectra indicated that EBI could generate defects, and NO 2 -sensing results at room temperature showed a decreased NO 2 response after exposure to EBI at 100 kGy; further increasing the dose to 500 kGy resulted in p-type semiconducting conductivity. The conversion of GO from n-type to p-type via EBI is explained not only through the generation of holes but also the variation in the amount of residual functional groups, including carboxyl (COOH) and hydroxyl groups (C-OH). The obtained results suggest that EBI can be a useful tool to convert GO into a diverse range of sensing devices.

  9. Assessment of training and technical assistance needs of Colorectal Cancer Control Program Grantees in the U.S.

    PubMed

    Escoffery, Cam; Hannon, Peggy; Maxwell, Annette E; Vu, Thuy; Leeman, Jennifer; Dwyer, Andrea; Mason, Caitlin; Sowles, Shaina; Rice, Ketra; Gressard, Lindsay

    2015-01-31

    Practitioners often require training and technical assistance to build their capacity to select, adapt, and implement evidence-based interventions (EBIs). The CDC Colorectal Cancer Control Program (CRCCP) aims to promote CRC screening to increase population-level screening. This study identified the training and technical assistance (TA) needs and preferences for training related to the implementation of EBIs among CRCCP grantees. Twenty-nine CRCCP grantees completed an online survey about their screening activities, training and technical assistance in 2012. They rated desire for training on various evidence-based strategies to increase cancer screening, evidence-based competencies, and program management topics. They also reported preferences for training formats and facilitators and barriers to trainings. Many CRCCP grantees expressed the need for training with regards to specific EBIs, especially system-level and provider-directed EBIs to promote CRC screening. Grantees rated these EBIs as more difficult to implement than client-oriented EBIs. Grantees also reported a moderate need for training regarding finding EBIs, assessing organizational capacity, implementing selected EBIs, and conducting process and outcome evaluations. Other desired training topics reported with higher frequency were partnership development and data collection/evaluation. Grantees preferred training formats that were interactive such as on-site trainings, webinars or expert consultants. Public health organizations need greater supports for adopting evidence-based interventions, working with organizational-level change, partnership development and data management. Future capacity building efforts for the adoption of EBIs should focus on systems or provider level interventions and key processes for health promotion and should be delivered in a variety of ways to assist local organizations in cancer prevention and control.

  10. Implementing Evidence-Based Teen Pregnancy-Prevention Interventions in a Community-Wide Initiative: Building Capacity and Reaching Youth.

    PubMed

    House, L Duane; Tevendale, Heather D; Martinez-Garcia, Genevieve

    2017-03-01

    To describe efforts to implement evidence-based interventions (EBIs) within multicomponent, community-wide initiatives to reduce teen pregnancy. During 2011-2014, we collected information about the capacity (i.e., knowledge, confidence, training, and experience) of state and community-based organizations to support implementation of the following: EBIs, number and characteristics of youth served by EBIs, type of EBIs implemented, EBI settings, hours of training, and technical assistance provided. State and community-based organizations reported these data annually; however, training and technical assistance was reported monthly. We used aggregated data from these annual and monthly reports to describe the implementation of EBIs in the community-wide initiative project. From baseline in 2011-2014, state and community-based organizations increased their capacities to support program partners in delivering EBIs. They provided 5,015 hours of technical assistance and training on topics, including ensuring adequate capacity, process and outcome evaluation, program planning, and continuous quality improvement. Program partners increased the number of youth reached by an EBI in targeted communities by 349%, from 4,304 in the first year of implementation in 2012 to 19,344 in 2014. Most youth in 2014 received sexuality education programs (59%), whereas smaller percentages received abstinence-based, youth development, and clinic-based programs. Most youth were reached through schools (72%) and community-based organizations (16%), and smaller numbers were reached in other settings (e.g., faith-based organizations, health centers). Building and monitoring the capacity of program partners to deliver EBIs through technical assistance and training is important. In addition, partnering with schools leads to reaching more youth. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  11. Implementation of Evidence-Based HIV Interventions for Gay, Bisexual, and Other Men Who Have Sex with Men.

    PubMed

    Jeffries, William L; Garrett, Sherese; Phields, Miriam; Olubajo, Babatunde; Lemon, Emily; Valdés-Salgado, Raydel; Collins, Charles B

    2017-10-01

    The Centers for Disease Control and Prevention provides trainings to support implementation of five evidence-based HIV prevention interventions (EBIs) for men who have sex with men (MSM): d-up: Defend Yourself!; Many Men, Many Voices; Mpowerment; Personalized Cognitive Counseling; and Popular Opinion Leader. We evaluated trainees' implementation of these EBIs and, using multivariable logistic regression, examined factors associated with implementation. Approximately 43% of trainees had implemented the EBIs for which they received training. Implementation was associated with working in community-based organizations (vs. health departments or other settings); acquiring training for Mpowerment or Popular Opinion Leader (vs. Personalized Cognitive Counseling); having ≥3 funding sources (vs. one); and having (vs. not having) sufficient time and necessary EBI resources. Findings suggest that implementation may vary by trainee characteristics, especially those related to employment setting, EBI training, funding, and perceived implementation barriers. Efforts that address these factors may help to improve EBI implementation among trainees.

  12. Moderate Effects of Same-Sex Legislation on Dependent Employer-Based Insurance Coverage among Sexual Minorities

    PubMed Central

    Tran, Linda Diem

    2016-01-01

    A difference-in-difference approach was used to compare the effects of same-sex domestic partnership, civil union, and marriage policies on same- and different-sex partners who could have benefitted from their partners’ employer-based insurance (EBI) coverage. Same-sex partners had 78% lower odds (ME=-21%) of having EBI compared to different-sex partners, adjusting for socioeconomic and health-related factors. Same-sex partners living in states that recognized same-sex marriage or domestic partnership had 89% greater odds of having EBI compared to those in states that did not recognize same-sex unions (ME=5%). The impact of same-sex legislation on increasing take-up of dependent EBI coverage among lesbians, gay men, and bisexual individuals (LGBs) was modest, and domestic partnership legislation was equally as effective as same-sex marriage in increasing same-sex partner EBI coverage. Extending dependent EBI coverage to same-sex partners can mitigate gaps in coverage for a segment of the LGB population but will not eliminate them. PMID:26762647

  13. Water Quality Vocabulary Development and Deployment

    NASA Astrophysics Data System (ADS)

    Simons, B. A.; Yu, J.; Cox, S. J.

    2013-12-01

    Semantic descriptions of observed properties and associated units of measure are fundamental to understanding of environmental observations, including groundwater, surface water and marine water quality. Semantic descriptions can be captured in machine-readable ontologies and vocabularies, thus providing support for the annotation of observation values from the disparate data sources with appropriate and accurate metadata, which is critical for achieving semantic interoperability. However, current stand-alone water quality vocabularies provide limited support for cross-system comparisons or data fusion. To enhance semantic interoperability, the alignment of water-quality properties with definitions of chemical entities and units of measure in existing widely-used vocabularies is required. Modern ontologies and vocabularies are expressed, organized and deployed using Semantic Web technologies. We developed an ontology for observed properties (i.e. a model for expressing appropriate controlled vocabularies) which extends the NASA/TopQuadrant QUDT ontology for Unit and QuantityKind with two additional classes and two properties (see accompanying paper by Cox, Simons and Yu). We use our ontology to populate the Water Quality vocabulary with a set of individuals of each of the four key classes (and their subclasses), and add appropriate relationships between these individuals. This ontology is aligned with other relevant stand-alone Water Quality vocabularies and domain ontologies. Developing the Water Quality vocabulary involved two main steps. First, the Water Quality vocabulary was populated with individuals of the ObservedProperty class, which was determined from a census of existing datasets and services. Each ObservedProperty individual relates to other individuals of Unit and QuantityKind (taken from QUDT where possible), and to IdentifiedObject individuals. As a large fraction of observed water quality data are classified by the chemical substance involved, the IdentifiedObject individuals are linked to the ChEBI ontology for definitions of chemical substances.. Second, to allow compatibility with SKOS-based tools and to ensure the vocabulary does not violate the meta-modelling constraints of the OWL-DL profile, the relevant classes in QUDT are declared to be subclasses of SKOS Concept and a shadow SKOS view of ChEBI was generated (as ChEBI models all elements and substances as OWL classes). The provenance of each SKOS concept shadowing an OWL class is recorded using the PROV-O ontology. Some aspects of these processing steps can be automated through SPARQL queries, while other aspects must be done manually. For maintenance and provenance purposes, the complete vocabulary and ontologies are persisted in around 20 separate RDF files (in addition to the QUDT and ChEBI sources), each of which constitutes a separate RDF graph and reflects the various aspects of above steps. The vocabularies are published in multiple ways: - For download as files from the ontology URI - At a SPARQL endpoint - Through a URI-based SKOS API (SISSvoc) - Through search UIs built on top of the SPARQL endpoint or SISSvoc service

  14. A mixed methods study of individual and organizational factors that affect implementation of interventions for children with autism in public schools.

    PubMed

    Locke, Jill; Beidas, Rinad S; Marcus, Steven; Stahmer, Aubyn; Aarons, Gregory A; Lyon, Aaron R; Cannuscio, Carolyn; Barg, Frances; Dorsey, Shannon; Mandell, David S

    2016-10-10

    The significant lifelong impairments associated with autism spectrum disorder (ASD), combined with the growing number of children diagnosed with ASD, have created urgency in improving school-based quality of care. Although many interventions have shown efficacy in university-based research, few have been effectively implemented and sustained in schools, the primary setting in which children with ASD receive services. Individual- and organizational-level factors have been shown to predict the implementation of evidence-based interventions (EBIs) for the prevention and treatment of other mental disorders in schools, and may be potential targets for implementation strategies in the successful use of autism EBIs in schools. The purpose of this study is to examine the individual- and organizational-level factors associated with the implementation of EBIs for children with ASD in public schools. We will apply the Domitrovich and colleagues (2008) framework that examines the influence of contextual factors (i.e., individual- and organizational-level factors) on intervention implementation in schools. We utilize mixed methods to quantitatively test whether the factors identified in the Domitrovich and colleagues (2008) framework are associated with the implementation of autism EBIs, and use qualitative methods to provide a more comprehensive understanding of the factors associated with successful implementation and sustainment of these interventions with the goal of tailoring implementation strategies. The results of this study will provide an in-depth understanding of individual- and organizational-level factors that influence the successful implementation of EBIs for children with ASD in public schools. These data will inform potential implementation targets and tailoring of strategies that will help schools overcome barriers to implementation and ultimately improve the services and outcomes for children with ASD.

  15. Predictive Toxicology: Current Status and Future Outlook (EBI ...

    EPA Pesticide Factsheets

    Slide presentation at the EBI-EMBL Industry Programme Workshop on Predictive Toxicology and the currently status of Computational Toxicology activities at the US EPA. Slide presentation at the EBI-EMBL Industry Programme Workshop on Predictive Toxicology and the currently status of Computational Toxicology activities at the US EPA.

  16. The EBI search engine: EBI search as a service-making biological data accessible for all.

    PubMed

    Park, Young M; Squizzato, Silvano; Buso, Nicola; Gur, Tamer; Lopez, Rodrigo

    2017-07-03

    We present an update of the EBI Search engine, an easy-to-use fast text search and indexing system with powerful data navigation and retrieval capabilities. The interconnectivity that exists between data resources at EMBL-EBI provides easy, quick and precise navigation and a better understanding of the relationship between different data types that include nucleotide and protein sequences, genes, gene products, proteins, protein domains, protein families, enzymes and macromolecular structures, as well as the life science literature. EBI Search provides a powerful RESTful API that enables its integration into third-party portals, thus providing 'Search as a Service' capabilities, which are the main topic of this article. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  17. Epstein-Barr virus-induced gene 3 (EBI3) polymorphisms and expression are associated with susceptibility to pulmonary tuberculosis.

    PubMed

    Zheng, Ruijuan; Liu, Haipeng; Song, Peng; Feng, Yonghong; Qin, Lianhua; Huang, Xiaochen; Chen, Jianxia; Yang, Hua; Liu, Zhonghua; Cui, Zhenglin; Hu, Zhongyi; Ge, Baoxue

    2015-07-01

    Tuberculosis (TB) remains a major global health problem and host genetic factors play a critical role in susceptibility and resistance to TB. The aim of this study was to identify novel candidate genes associated with TB susceptibility. We performed a population-based case-control study to genotype 13 tag SNPs spanning Epstein-Barr virus-induced gene 3 (EBI3), colony stimulating factor 2 (CSF2), IL-4, interferon beta 1 (IFNB1), chemokine (C-X-C motif) ligand 14 (CXCL14) and myeloid differentiation primary response gene 88 (Myd88) genes in 435 pulmonary TB patients and 375 health donors from China. We observed that EBI3 gene rs4740 polymorphism was associated with susceptibility to pulmonary tuberculosis (PTB) and the allele G was associated with a protective effect against PTB. Furthermore, EBI3 deficiency led to reduced bacterial burden and histopathological impairment in the lung of mice infected with Mycobacterium bovis BCG. Meanwhile, higher abundance of EBI3 was observed in the granuloma of PTB patients and in the lung tissue of BCG-infected mice. Of note, the expression of EBI3 in macrophages was remarkably induced by mycobacteria infection at both mRNA and protein level. In conclusion, EBI3 gene rs4740 polymorphism is closely associated with susceptibility to PTB and the elevation and enrichment of EBI3 in the lung which at least partially derived from macrophages may contribute to the exacerbation of mycobacterial infection. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Developing Theory to Guide Building Practitioners' Capacity to Implement Evidence-Based Interventions

    ERIC Educational Resources Information Center

    Leeman, Jennifer; Calancie, Larissa; Kegler, Michelle C.; Escoffery, Cam T.; Herrmann, Alison K.; Thatcher, Esther; Hartman, Marieke A.; Fernandez, Maria E.

    2017-01-01

    Public health and other community-based practitioners have access to a growing number of evidence-based interventions (EBIs), and yet EBIs continue to be underused. One reason for this underuse is that practitioners often lack the capacity (knowledge, skills, and motivation) to select, adapt, and implement EBIs. Training, technical assistance, and…

  19. Moderate Effects of Same-Sex Legislation on Dependent Employer-Based Insurance Coverage Among Sexual Minorities.

    PubMed

    Tran, Linda Diem

    2016-12-01

    A difference-in-difference approach was used to compare the effects of same-sex domestic partnership, civil union, and marriage policies on same- and different-sex partners who could have benefitted from their partners' employer-based insurance (EBI) coverage. Same-sex partners had 78% lower odds (Marginal Effect = -21%) of having EBI compared with different-sex partners, adjusting for socioeconomic and health-related factors. Same-sex partners living in states that recognized same-sex marriage or domestic partnership had 89% greater odds of having EBI compared with those in states that did not recognize same-sex unions (ME = 5%). The impact of same-sex legislation on increasing take-up of dependent EBI coverage among lesbians, gay men, and bisexual individuals was modest, and domestic partnership legislation was equally as effective as same-sex marriage in increasing same-sex partner EBI coverage. Extending dependent EBI coverage to same-sex partners can mitigate gaps in coverage for a segment of the lesbians, gay men, and bisexual population but will not eliminate them. © The Author(s) 2016.

  20. Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion sourcea)

    NASA Astrophysics Data System (ADS)

    Kondo, K.; Yamamoto, T.; Sekine, M.; Okamura, M.

    2012-02-01

    The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current (˜100 μA) with high charge (˜10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.

  1. Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion source.

    PubMed

    Kondo, K; Yamamoto, T; Sekine, M; Okamura, M

    2012-02-01

    The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current (∼100 μA) with high charge (∼10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.

  2. Dovetailing biology and chemistry: integrating the Gene Ontology with the ChEBI chemical ontology

    PubMed Central

    2013-01-01

    Background The Gene Ontology (GO) facilitates the description of the action of gene products in a biological context. Many GO terms refer to chemical entities that participate in biological processes. To facilitate accurate and consistent systems-wide biological representation, it is necessary to integrate the chemical view of these entities with the biological view of GO functions and processes. We describe a collaborative effort between the GO and the Chemical Entities of Biological Interest (ChEBI) ontology developers to ensure that the representation of chemicals in the GO is both internally consistent and in alignment with the chemical expertise captured in ChEBI. Results We have examined and integrated the ChEBI structural hierarchy into the GO resource through computationally-assisted manual curation of both GO and ChEBI. Our work has resulted in the creation of computable definitions of GO terms that contain fully defined semantic relationships to corresponding chemical terms in ChEBI. Conclusions The set of logical definitions using both the GO and ChEBI has already been used to automate aspects of GO development and has the potential to allow the integration of data across the domains of biology and chemistry. These logical definitions are available as an extended version of the ontology from http://purl.obolibrary.org/obo/go/extensions/go-plus.owl. PMID:23895341

  3. Early Brain Injury Associated with Systemic Inflammation After Subarachnoid Hemorrhage.

    PubMed

    Savarraj, Jude; Parsha, Kaushik; Hergenroeder, Georgene; Ahn, Sungho; Chang, Tiffany R; Kim, Dong H; Choi, H Alex

    2018-04-01

    Early brain injury (EBI) after aneurysmal subarachnoid hemorrhage (aSAH) is defined as brain injury occurring within 72 h of aneurysmal rupture. Although EBI is the most significant predictor of outcomes after aSAH, its underlying pathophysiology is not well understood. We hypothesize that EBI after aSAH is associated with an increase in peripheral inflammation measured by cytokine expression levels and changes in associations between cytokines. aSAH patients were enrolled into a prospective observational study and were assessed for markers of EBI: global cerebral edema (GCE), subarachnoid hemorrhage early brain edema score (SEBES), and Hunt-Hess grade. Serum samples collected at ≤ 48 h of admission were analyzed using multiplex bead-based assays to determine levels of 13 pro- and anti-inflammatory cytokines. Pairwise correlation coefficients between cytokines were represented as networks. Cytokine levels and differences in correlation networks were compared between EBI groups. Of the 71 patients enrolled in the study, 17 (24%) subjects had GCE, 31 (44%) subjects had SEBES ≥ 3, and 21 (29%) had HH ≥ 4. IL-6 was elevated in groups with GCE, SEBES ≥ 3, and HH ≥ 4. MIP1β was independently associated with high-grade SEBES. Correlation network analysis suggests higher systematic inflammation in subjects with SEBES ≥ 3. EBI after SAH is associated with increased levels of specific cytokines. Peripheral levels of IL-10, IL-6, and MIP1β may be important markers of EBI. Investigating systematic correlations in addition to expression levels of individual cytokines may offer deeper insight into the underlying mechanisms related to EBI.

  4. Extreme Algal Bloom Detection with MERIS

    NASA Astrophysics Data System (ADS)

    Amin, R.; Gilerson, A.; Gould, R.; Arnone, R.; Ahmed, S.

    2009-05-01

    Harmful Algal Blooms (HAB's) are a major concern all over the world due to their negative impacts on the marine environment, human health, and the economy. Their detection from space still remains a challenge particularly in turbid coastal waters. In this study we propose a simple reflectance band difference approach for use with Medium Resolution Imaging Spectrometer (MERIS) data to detect intense plankton blooms. For convenience we label this approach as the Extreme Bloom Index (EBI) which is defined as EBI = Rrs (709) - Rrs (665). Our initial analysis shows that this band difference approach has some advantages over the band ratio approaches, particularly in reducing errors due to imperfect atmospheric corrections. We also do a comparison between the proposed EBI technique and the Maximum Chlorophyll Index (MCI) Gower technique. Our preliminary result shows that both the EBI and MCI indeces detect intense plankton blooms, however, MCI is more vulnerable in highly scattering waters, giving more positive false alarms than EBI.

  5. Adapting an evidence-based intervention for homeless women: engaging the community in shared decision-making.

    PubMed

    Cederbaum, Julie A; Song, Ahyoung; Hsu, Hsun-Ta; Tucker, Joan S; Wenzel, Suzanne L

    2014-11-01

    As interest grows in the diffusion of evidence-based interventions (EBIs), there is increasing concern about how to mitigate implementation challenges; this paper concerns adapting an EBI for homeless women. Complementing earlier focus groups with homeless women, homeless service providers (n = 32) were engaged in focus groups to assess capacity, needs, and barriers with implementation of EBIs. Deductive analyses of data led to the selection of four EBIs. Six consensus groups were then undertaken; three each with homeless women (n = 24) and homeless service providers (n = 21). The selected EBI was adapted and pretested with homeless women (n = 9) and service providers (n = 6). The structured consensus group process provided great utility and affirmed the expertise of homeless women and service providers as experts in their domain. Engaging providers in the selection process reduced the structural barriers within agencies as obstacles to diffusion.

  6. Cultural Adaptation of a U.S. Evidence-Based Parenting Intervention for Rural Western Kenya: From Parents Matter! to Families Matter!

    ERIC Educational Resources Information Center

    Poulsen, Melissa N.; Vandenhoudt, Hilde; Wyckoff, Sarah C.; Obong'o, Christopher O.; Ochura, Juliet; Njika, Gillian; Otwoma, Nelson Juma; Miller, Kim S.

    2010-01-01

    Evidence-based interventions (EBIs) are critical for effective HIV prevention, but time and resources required to develop and evaluate new interventions are limited. Alternatively, existing EBIs can be adapted for new settings if core elements remain intact. We describe the process of adapting the Parents Matter! Program, an EBI originally…

  7. Electrical bioimpedance enabling prompt intervention in traumatic brain injury

    NASA Astrophysics Data System (ADS)

    Seoane, Fernando; Atefi, S. Reza

    2017-05-01

    Electrical Bioimpedance (EBI) is a well spread technology used in clinical practice across the world. Advancements in Textile material technology with conductive textile fabrics and textile-electronics integration have allowed exploring potential applications for Wearable Measurement Sensors and Systems exploiting. The sensing principle of electrical bioimpedance is based on the intrinsic passive dielectric properties of biological tissue. Using a pair of electrodes, tissue is electrically stimulated and the electrical response can be sensed with another pair of surface electrodes. EBI spectroscopy application for cerebral monitoring of neurological conditions such as stroke and perinatal asphyxia in newborns have been justified using animal studies and computational simulations. Such studies have shown proof of principle that neurological pathologies indeed modify the dielectric composition of the brain that is detectable via EBI. Similar to stroke, Traumatic Brain Injury (TBI) also affects the dielectric properties of brain tissue that can be detected via EBI measurements. Considering the portable and noninvasive characteristics of EBI it is potentially useful for prehospital triage of TBI patients where. In the battlefield blast induced Traumatic Brain Injuries are very common. Brain damage must be assessed promptly to have a chance to prevent severe damage or eventually death. The relatively low-complexity of the sensing hardware required for EBI sensing and the already proven compatibility with textile electrodes suggest the EBI technology is indeed a candidate for developing a handheld device equipped with a sensorized textile cap to produce an examination in minutes for enabling medically-guided prompt intervention.

  8. Non-invasive method for the aortic blood pressure waveform estimation using the measured radial EBI

    NASA Astrophysics Data System (ADS)

    Krivoshei, Andrei; Lamp, Jürgen; Min, Mart; Uuetoa, Tiina; Uuetoa, Hasso; Annus, Paul

    2013-04-01

    The paper presents a method for the Central Aortic Pressure (CAP) waveform estimation from the measured radial Electrical Bio-Impedance (EBI). The method proposed here is a non-invasive and health-safe approach to estimate the cardiovascular system parameters, such as the Augmentation Index (AI). Reconstruction of the CAP curve from the EBI data is provided by spectral domain transfer functions (TF), found on the bases of data analysis. Clinical experiments were carried out on 30 patients in the Center of Cardiology of East-Tallinn Central Hospital during coronary angiography on patients in age of 43 to 80 years. The quality and reliability of the method was tested by comparing the evaluated augmentation indices obtained from the invasively measured CAP data and from the reconstructed curve. The correlation coefficient r = 0.89 was calculated in the range of AICAP values from 5 to 28. Comparing to the traditional tonometry based method, the developed one is more convenient to use and it allows long-term monitoring of the AI, what is not possible with tonometry probes.

  9. Exploring Implementation and Fidelity of Evidence-Based Behavioral Interventions for HIV Prevention: Lessons Learned from the Focus on Kids Diffusion Case Study

    ERIC Educational Resources Information Center

    Galbraith, Jennifer S.; Stanton, Bonita; Boekeloo, Bradley; King, Winifred; Desmond, Sharon; Howard, Donna; Black, Maureen M.; Carey, James W.

    2009-01-01

    Evidence-based interventions (EBIs) are used in public health to prevent HIV infection among youth and other groups. EBIs include core elements, features that are thought to be responsible for the efficacy of interventions. The authors evaluate experiences of organizations that adopted an HIV-prevention EBI, Focus on Kids (FOK), and their fidelity…

  10. Measurement of Epistemological Beliefs: Psychometric Properties of the EQEBI Test Scores

    ERIC Educational Resources Information Center

    Ordonez, Xavier G.; Ponsoda, Vicente; Abad, Francisco J.; Romero, Sonia J.

    2009-01-01

    This article proposes a new test (called the EQEBI) for the measurement of epistemological beliefs, integrating and extending the Epistemological Questionnaire (EQ) and the Epistemic Beliefs Inventory (EBI). In Study 1, the two tests were translated and applied to a Spanish-speaking sample. A detailed dimensionality exploration, by means of the…

  11. InterProScan 5: genome-scale protein function classification

    PubMed Central

    Jones, Philip; Binns, David; Chang, Hsin-Yu; Fraser, Matthew; Li, Weizhong; McAnulla, Craig; McWilliam, Hamish; Maslen, John; Mitchell, Alex; Nuka, Gift; Pesseat, Sebastien; Quinn, Antony F.; Sangrador-Vegas, Amaia; Scheremetjew, Maxim; Yong, Siew-Yit; Lopez, Rodrigo; Hunter, Sarah

    2014-01-01

    Motivation: Robust large-scale sequence analysis is a major challenge in modern genomic science, where biologists are frequently trying to characterize many millions of sequences. Here, we describe a new Java-based architecture for the widely used protein function prediction software package InterProScan. Developments include improvements and additions to the outputs of the software and the complete reimplementation of the software framework, resulting in a flexible and stable system that is able to use both multiprocessor machines and/or conventional clusters to achieve scalable distributed data analysis. InterProScan is freely available for download from the EMBl-EBI FTP site and the open source code is hosted at Google Code. Availability and implementation: InterProScan is distributed via FTP at ftp://ftp.ebi.ac.uk/pub/software/unix/iprscan/5/ and the source code is available from http://code.google.com/p/interproscan/. Contact: http://www.ebi.ac.uk/support or interhelp@ebi.ac.uk or mitchell@ebi.ac.uk PMID:24451626

  12. Investigations of the emittance and brightness of ion beams from an electron beam ion source of the Dresden EBIS type.

    PubMed

    Silze, Alexandra; Ritter, Erik; Zschornack, Günter; Schwan, Andreas; Ullmann, Falk

    2010-02-01

    We have characterized ion beams extracted from the Dresden EBIS-A, a compact room-temperature electron beam ion source (EBIS) with a permanent magnet system for electron beam compression, using a pepper-pot emittance meter. The EBIS-A is the precursor to the Dresden EBIS-SC in which the permanent magnets have been replaced by superconducting solenoids for the use of the source in high-ion-current applications such as heavy-ion cancer therapy. Beam emittance and brightness values were calculated from data sets acquired for a variety of source parameters, in leaky as well as pulsed ion extraction mode. With box shaped pulses of C(4+) ions at an energy of 39 keV root mean square emittances of 1-4 mm mrad and a brightness of 10 nA mm(-2) mrad(-2) were achieved. The results meet the expectations for high quality ion beams generated by an electron beam ion source.

  13. Impact of Human Resources on Implementing an Evidence-based HIV Prevention Intervention

    PubMed Central

    McKay, Virginia R.; Dolcini, M. Margaret; Catania, Joseph A.

    2016-01-01

    Evidence-based interventions (EBIs) often require competent staff, or human resources (HR), for implementation. The empirical evidence characterizing the influence of HR fluctuations on EBI delivery is limited and conflicting. Using the Interactive Systems Framework, we explored staff fluctuation and the subsequent influence on RESPECT, an HIV prevention EBI. Methods We conducted interviews with staff in two waves (n=53, Wave I; n=37, Wave II) in a national sample of organizations delivering RESPECT (N=29). We analyzed interviews qualitatively to describe changes among RESPECT staff and explore the subsequent influences on RESPECT implementation. Results Organizations reported downsizing, turnover, and expansion of staff positions. Staff changes had multiple influences on RESPECT implementation including clients reached, fidelity to specific RESPECT protocols, and overall sustainability of RESPECT over time. Discussion HR fluctuations are common, and our analyses provide an initial characterization of the relationship between HR fluctuation and EBI implementation. Given the prominent influence of HR on EBI implementation, the Interactive Systems Framework is a useful guiding tool for future examinations. PMID:27150896

  14. Signaling Pathway in Early Brain Injury after Subarachnoid Hemorrhage: News Update.

    PubMed

    Ji, Chengyuan; Chen, Gang

    2016-01-01

    The annual incidence of subarachnoid hemorrhage (SAH) caused by intracranial aneurysm rupture is approximately 10.5/10 million people in China, making SAH the third most frequently occurring hemorrhage of the intracranial type after cerebral embolism and hypertensive intracerebral hemorrhage. SAH caused by ruptured aneurysm leads to a mortality rate as high as 67 %, and, because of the sudden onset of this disease, approximately 12-15 % of patients die before they can receive effective treatment. Early brain injury (EBI) is the brain damage occurring within the first 72 h after SAH. Two-thirds of mortality caused by SAH occurs within 48 h, mainly as a result of EBI. With the development of molecular biology and medicine microscopy techniques, various signaling pathways involved in EBI after SAH have been revealed. Understanding these signaling pathways may help clinicians treat EBI after SAH and improve long-term prognosis of SAH patients. This chapter summarizes several important signaling pathways implicated in EBI caused by SAH.

  15. Portfolio Management

    NASA Technical Reports Server (NTRS)

    Duncan, Sharon L.

    2011-01-01

    Enterprise Business Information Services Division (EBIS) supports the Laboratory and its functions through the implementation and support of business information systems on behalf of its business community. EBIS Five Strategic Focus Areas: (1) Improve project estimating, planning and delivery capability (2) Improve maintainability and sustainability of EBIS Application Portfolio (3) Leap forward in IT Leadership (4) Comprehensive Talent Management (5) Continuous IT Security Program. Portfolio Management is a strategy in which software applications are managed as assets

  16. Decreased interleukin 35 and CD4+EBI3+ T cells in patients with active systemic lupus erythematosus.

    PubMed

    Ouyang, Han; Shi, Yong-Bing; Liu, Zhi-Chun; Wang, Zhi; Feng, Sheng; Kong, Shu-Min; Lu, Ying

    2014-08-01

    Interleukin 35 (IL-35) is likely to contribute to the development of autoimmune diseases, as the Epstein-Barr virus-induced gene protein 3 (EBI3) is the specificity subunit of IL-35. Nevertheless, until recently, no studies have evaluated its role in systemic lupus erythematosus (SLE) in humans. The objective of this study was to investigate the serum IL-35 level and the percentage of CD4EBI3 T cells in the peripheral blood of patients with SLE and explore the roles of double-positive T cells and IL-35 in the pathogenesis of SLE and the effects of glucocorticoid on these roles. Fifty-five hospitalized patients with SLE were recruited, and 20 volunteers were enrolled as healthy controls. Serum IL-35 levels were measured by enzyme-linked immunosorbent assay, and the percentage of CD4EBI3 T cells was analyzed by flow cytometry. The serum IL-35 level and the percentage of CD4EBI3 T cells were significantly decreased in patients with active SLE compared with healthy controls and patients with inactive SLE. The serum IL-35 level and the percentage of CD4EBI3 T cells were negatively correlated with the SLE disease activity index. The percentages of CD4EBI3 T cells and serum IL-35 levels in 10 untreated patients with active SLE were increased at days l, 3, and 7 after the treatment with methylprednisolone (0.8 mg·kg·d) compared with the percentages before the treatment. These results demonstrate that abnormalities in IL-35 and CD4EBI3 T cells may play important roles in the pathogenesis of SLE; the percentage of double-positive T cells and the level of IL-35 are parameters for the evaluation of SLE activity and severity.

  17. Restoration of stormwater retention capacity at the allotment-scale through a novel economic instrument.

    PubMed

    Fletcher, Tim D; Walsh, Chistopher J; Bos, Darren; Nemes, Veronika; RossRakesh, Sharyn; Prosser, Toby; Hatt, Belinda; Birch, Rhiannon

    2011-01-01

    Urbanisation results in changes to runoff behaviour which, if not addressed, inevitably degrade receiving waters. To date, most stormwater management has focussed on the streetscape and public open space. Given that much of the catchment imperviousness is located on private land, we developed and tested a novel economic instrument (a uniform price auction) for encouraging allotment-scale stormwater retention. We evaluated bids using an integrated environmental benefit index (EBI), based on the ability of the proposed works to reduce runoff frequency, pollutant loads and to reduce potable water demand. The uniform price auction resulted in 1.4 ha of impervious areas being effectively 'disconnected' from the stormwater system. The EBI provided an objective and transparent method of comparing bids, which varied in the type of works proposed (e.g. rainwater tank, rain-garden), the cost and the resulting environmental benefit. Whilst the pilot auction was a success, the public subsidy of works undertaken was around 85%, meaning that property owners a relatively small private benefit in the works. Future auction rounds will be revised to (i) test an EBI which is more focussed on the protection of streams (assessing changes to runoff frequency, baseflow volumes and water quality) and (ii) provide an auction process which is simpler to understand, and provides greater practical support for landholders who wish to undertake works.

  18. Ionization of polarized 3He+ ions in EBIS trap with slanted electrostatic mirror.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikin,A.; Zelenski, A.; Kponou, A.

    2007-09-10

    Methods of producing the nuclear polarized {sup 3}He{sup +} ions and their ionization to {sup 3}H{sup ++} in ion trap of the electron Beam Ion Source (EBIS) are discussed. Computer simulations show that injection and accumulation of {sup 3}He{sup +} ions in the EBIS trap with slanted electrostatic mirror can be very effective for injection times longer than the ion traversal time through the trap.

  19. Ionization of polarized {sup 3}He{sup +} ions in EBIS trap with slanted electrostatic mirror

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikin, A.; Zelenski, A.; Kponou, A.

    2008-02-06

    Methods of producing the nuclear polarized {sup 3}He{sup +} ions and their ionization to {sup 3}He{sup ++} in ion trap of the electron Beam Ion Source (EBIS) are discussed. Computer simulations show that injection and accumulation of {sup 3}He{sup +} ions in the EBIS trap with slanted electrostatic mirror can be very effective for injection times longer than the ion traversal time through the trap.

  20. The new NHGRI-EBI Catalog of published genome-wide association studies (GWAS Catalog)

    PubMed Central

    MacArthur, Jacqueline; Bowler, Emily; Cerezo, Maria; Gil, Laurent; Hall, Peggy; Hastings, Emma; Junkins, Heather; McMahon, Aoife; Milano, Annalisa; Morales, Joannella; Pendlington, Zoe May; Welter, Danielle; Burdett, Tony; Hindorff, Lucia; Flicek, Paul; Cunningham, Fiona; Parkinson, Helen

    2017-01-01

    The NHGRI-EBI GWAS Catalog has provided data from published genome-wide association studies since 2008. In 2015, the database was redesigned and relocated to EMBL-EBI. The new infrastructure includes a new graphical user interface (www.ebi.ac.uk/gwas/), ontology supported search functionality and an improved curation interface. These developments have improved the data release frequency by increasing automation of curation and providing scaling improvements. The range of available Catalog data has also been extended with structured ancestry and recruitment information added for all studies. The infrastructure improvements also support scaling for larger arrays, exome and sequencing studies, allowing the Catalog to adapt to the needs of evolving study design, genotyping technologies and user needs in the future. PMID:27899670

  1. Numerical simulation of ion charge breeding in electron beam ion source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, L., E-mail: zhao@far-tech.com; Kim, Jin-Soo

    2014-02-15

    The Electron Beam Ion Source particle-in-cell code (EBIS-PIC) tracks ions in an EBIS electron beam while updating electric potential self-consistently and atomic processes by the Monte Carlo method. Recent improvements to the code are reported in this paper. The ionization module has been improved by using experimental ionization energies and shell effects. The acceptance of injected ions and the emittance of extracted ion beam are calculated by extending EBIS-PIC to the beam line transport region. An EBIS-PIC simulation is performed for a Cs charge-breeding experiment at BNL. The charge state distribution agrees well with experiments, and additional simulation results ofmore » radial profiles and velocity space distributions of the trapped ions are presented.« less

  2. Development of an EBIS charge breeder for the Rare Isotope Science Project

    NASA Astrophysics Data System (ADS)

    Son, Hyock-Jun; Park, Young-Ho; Kondrashev, Sergey; Kim, Jongwon; Lee, Bong Ju; Chung, Moses

    2017-10-01

    In Korea, a heavy ion accelerator facility called RAON is being designed to produce various rare isotopes for the Rare Isotope Science Project (RISP) (Jeong, 2016) [1], (Moon, 2014) [2]. This facility is designed to use both In-flight Fragment (IF) and Isotope Separation On-Line (ISOL) techniques in order to produce a wide variety of RI beams for nuclear physics experiments. An Electron Beam Ion Source (EBIS) will be used for charge breeding of Rare Isotope (RI) beams in the ISOL system. The charge-to-mass ratio (q/A) of the RI beams after charge breeding is ≥1/4. The highly charged RI beams will be accelerated by a linac post-accelerator and delivered to a low energy (∼18 MeV/u) experimental hall or the IF system. The RAON EBIS will use a 3 A electron gun and a 6 T superconducting solenoid for high capacity, high efficiency, and short breeding time. In front of the charge breeder, an RFQ cooler-buncher will be used to deliver a bunched beam with small emittance to the EBIS charge breeder. The main design of the RAON EBIS has been carried out on the basis of several beam analyses and technical reviews. In this paper, current progress of the development of the RAON EBIS charge breeder will be presented.

  3. Electrical bioimpedance and other techniques for gastric emptying and motility evaluation

    PubMed Central

    Huerta-Franco, María Raquel; Vargas-Luna, Miguel; Montes-Frausto, Juana Berenice; Flores-Hernández, Corina; Morales-Mata, Ismael

    2012-01-01

    The aim of this article is to identify non-invasive, inexpensive, highly sensitive and accurate techniques for evaluating and diagnosing gastric diseases. In the case of the stomach, there are highly sensitive and specific methods for assessing gastric motility and emptying (GME). However, these methods are invasive, expensive and/or not technically feasible for all clinicians and patients. We present a summary of the most relevant international information on non-invasive methods and techniques for clinically evaluating GME. We particularly emphasize the potential of gastric electrical bioimpedance (EBI). EBI was initially used mainly in gastric emptying studies and was essentially abandoned in favor of techniques such as electrogastrography and the gold standard, scintigraphy. The current research evaluating the utility of gastric EBI either combines this technique with other frequently used techniques or uses new methods for gastric EBI signal analysis. In this context, we discuss our results and those of other researchers who have worked with gastric EBI. In this review article, we present the following topics: (1) a description of the oldest methods and procedures for evaluating GME; (2) an explanation of the methods currently used to evaluate gastric activity; and (3) a perspective on the newest trends and techniques in clinical and research GME methods. We conclude that gastric EBI is a highly effective non-invasive, easy to use and inexpensive technique for assessing GME. PMID:22368782

  4. ChEBI in 2016: Improved services and an expanding collection of metabolites

    PubMed Central

    Hastings, Janna; Owen, Gareth; Dekker, Adriano; Ennis, Marcus; Kale, Namrata; Muthukrishnan, Venkatesh; Turner, Steve; Swainston, Neil; Mendes, Pedro; Steinbeck, Christoph

    2016-01-01

    ChEBI is a database and ontology containing information about chemical entities of biological interest. It currently includes over 46 000 entries, each of which is classified within the ontology and assigned multiple annotations including (where relevant) a chemical structure, database cross-references, synonyms and literature citations. All content is freely available and can be accessed online at http://www.ebi.ac.uk/chebi. In this update paper, we describe recent improvements and additions to the ChEBI offering. We have substantially extended our collection of endogenous metabolites for several organisms including human, mouse, Escherichia coli and yeast. Our front-end has also been reworked and updated, improving the user experience, removing our dependency on Java applets in favour of embedded JavaScript components and moving from a monthly release update to a ‘live’ website. Programmatic access has been improved by the introduction of a library, libChEBI, in Java, Python and Matlab. Furthermore, we have added two new tools, namely an analysis tool, BiNChE, and a query tool for the ontology, OntoQuery. PMID:26467479

  5. Electron beam induced etching of carbon nanotubes enhanced by secondary electrons in oxygen.

    PubMed

    Yoshida, Hideto; Tomita, Yuto; Soma, Kentaro; Takeda, Seiji

    2017-05-12

    Multi-walled carbon nanotubes (CNTs) are subjected to electron-beam-induced etching (EBIE) in oxygen. The EBIE process is observed in situ by environmental transmission electron microscopy. The partial pressure of oxygen (10 and 100 Pa), energy of the primary electrons (80 and 200 keV), and environment of the CNTs (suspended or supported on a silicon nitride membrane) are investigated as factors affecting the etching rate. The EBIE rate of CNTs was markedly promoted by the effects of secondary electrons that were emitted from a silicon nitride membrane under irradiation by primary electrons. Membrane supported CNTs can be cut by EBIE with a spatial accuracy better than 3 nm, and a nanogap of 2 nm can be successfully achieved between the ends of two suspended CNTs.

  6. Ebi3 Prevents Trypanosoma cruzi-Induced Myocarditis by Dampening IFN-γ-Driven Inflammation.

    PubMed

    Medina, Tiago Silva; Oliveira, Gabriela Gonçalves; Silva, Maria Cláudia; David, Bruna Araújo; Silva, Grace Kelly; Fonseca, Denise Morais; Sesti-Costa, Renata; Frade, Amanda Farage; Baron, Monique Andrade; Ianni, Barbara; Pereira, Alexandre Costa; Chevillard, Christophe; Cunha-Neto, Edécio; Marin-Neto, José Antonio; Silva, João Santana

    2017-01-01

    The identification of anti-inflammatory mediators can reveal important targetable molecules capable of counterbalancing Trypanosoma cruzi -induced myocarditis. Composed of Ebi3 and IL-27p28 subunits, IL-27 is produced by myeloid cells and is able to suppress inflammation by inducing IL-10-producing Tr1 cells, thus emerging as a potential candidate to ameliorate cardiac inflammation induced by T. cruzi . Although IL-27 has been extensively characterized as a suppressive cytokine that prevents liver immunopathogenesis after T. cruzi infection, the mechanisms underlying its effects on T. cruzi -induced myocarditis remain largely unknown. Here, wild-type (WT) and Ebi3-deficient animals were intraperitoneally infected with trypomastigotes of T. cruzi Y strain and used to evaluate the potential anti-inflammatory properties of Ebi3 during T. cruzi infection. The survival rates of mice were daily recorded, the frequency of inflammatory cells was analyzed by flow cytometry and inflammatory mediators were measured by ELISA, real-time PCR and PCR array. We reported that T. cruzi -induced myocarditis was prevented by Ebi3. Stressors mainly recognized by TLR2 and TLR4 receptors on myeloid cells were essential to trigger IL-27p28 production. In addition, Ebi3 regulated IFN-γ-mediated myocarditis by promoting an anti-inflammatory environment through IL-10, which was most likely produced by Tr1 cells rather than classical regulatory T cells (Tregs), in the heart tissue of T. cruzi -infected animals. Furthermore, in vivo IFN-γ blockade ameliorated the host survival without compromising the parasite control in the bloodstream. In humans, IL-27p28 was correlated with cardiac protection during Chagas disease. Patients with mild clinical forms of the disease produced high levels of IL-27p28, whereas lower levels were found in those with severe forms. In addition, polymorphic sites at Ebi3 gene were associated with severe cardiomyopathy in patients with Chagas disease. Collectively, we describe a novel regulatory mechanism where Ebi3 dampens cardiac inflammation by modulating the overproduction of IFN-γ, the bona fide culprit of Chagas disease cardiomyopathy.

  7. Ebi3 Prevents Trypanosoma cruzi-Induced Myocarditis by Dampening IFN-γ-Driven Inflammation

    PubMed Central

    Medina, Tiago Silva; Oliveira, Gabriela Gonçalves; Silva, Maria Cláudia; David, Bruna Araújo; Silva, Grace Kelly; Fonseca, Denise Morais; Sesti-Costa, Renata; Frade, Amanda Farage; Baron, Monique Andrade; Ianni, Barbara; Pereira, Alexandre Costa; Chevillard, Christophe; Cunha-Neto, Edécio; Marin-Neto, José Antonio; Silva, João Santana

    2017-01-01

    The identification of anti-inflammatory mediators can reveal important targetable molecules capable of counterbalancing Trypanosoma cruzi-induced myocarditis. Composed of Ebi3 and IL-27p28 subunits, IL-27 is produced by myeloid cells and is able to suppress inflammation by inducing IL-10-producing Tr1 cells, thus emerging as a potential candidate to ameliorate cardiac inflammation induced by T. cruzi. Although IL-27 has been extensively characterized as a suppressive cytokine that prevents liver immunopathogenesis after T. cruzi infection, the mechanisms underlying its effects on T. cruzi-induced myocarditis remain largely unknown. Here, wild-type (WT) and Ebi3-deficient animals were intraperitoneally infected with trypomastigotes of T. cruzi Y strain and used to evaluate the potential anti-inflammatory properties of Ebi3 during T. cruzi infection. The survival rates of mice were daily recorded, the frequency of inflammatory cells was analyzed by flow cytometry and inflammatory mediators were measured by ELISA, real-time PCR and PCR array. We reported that T. cruzi-induced myocarditis was prevented by Ebi3. Stressors mainly recognized by TLR2 and TLR4 receptors on myeloid cells were essential to trigger IL-27p28 production. In addition, Ebi3 regulated IFN-γ-mediated myocarditis by promoting an anti-inflammatory environment through IL-10, which was most likely produced by Tr1 cells rather than classical regulatory T cells (Tregs), in the heart tissue of T. cruzi-infected animals. Furthermore, in vivo IFN-γ blockade ameliorated the host survival without compromising the parasite control in the bloodstream. In humans, IL-27p28 was correlated with cardiac protection during Chagas disease. Patients with mild clinical forms of the disease produced high levels of IL-27p28, whereas lower levels were found in those with severe forms. In addition, polymorphic sites at Ebi3 gene were associated with severe cardiomyopathy in patients with Chagas disease. Collectively, we describe a novel regulatory mechanism where Ebi3 dampens cardiac inflammation by modulating the overproduction of IFN-γ, the bona fide culprit of Chagas disease cardiomyopathy. PMID:29033934

  8. The new NHGRI-EBI Catalog of published genome-wide association studies (GWAS Catalog).

    PubMed

    MacArthur, Jacqueline; Bowler, Emily; Cerezo, Maria; Gil, Laurent; Hall, Peggy; Hastings, Emma; Junkins, Heather; McMahon, Aoife; Milano, Annalisa; Morales, Joannella; Pendlington, Zoe May; Welter, Danielle; Burdett, Tony; Hindorff, Lucia; Flicek, Paul; Cunningham, Fiona; Parkinson, Helen

    2017-01-04

    The NHGRI-EBI GWAS Catalog has provided data from published genome-wide association studies since 2008. In 2015, the database was redesigned and relocated to EMBL-EBI. The new infrastructure includes a new graphical user interface (www.ebi.ac.uk/gwas/), ontology supported search functionality and an improved curation interface. These developments have improved the data release frequency by increasing automation of curation and providing scaling improvements. The range of available Catalog data has also been extended with structured ancestry and recruitment information added for all studies. The infrastructure improvements also support scaling for larger arrays, exome and sequencing studies, allowing the Catalog to adapt to the needs of evolving study design, genotyping technologies and user needs in the future. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.

  9. Use of Evidence-Based Interventions and Implementation Strategies to Increase Colorectal Cancer Screening in Federally Qualified Health Centers.

    PubMed

    Adams, Swann Arp; Rohweder, Catherine L; Leeman, Jennifer; Friedman, Daniela B; Gizlice, Ziya; Vanderpool, Robin C; Askelson, Natoshia; Best, Alicia; Flocke, Susan A; Glanz, Karen; Ko, Linda K; Kegler, Michelle

    2018-05-16

    While colorectal cancer (CRC) screening rates have been increasing in the general population, rates are considerably lower in Federally Qualified Health Centers (FQHCs), which serve a large proportion of uninsured and medically vulnerable patients. Efforts to screen eligible patients must be accelerated if we are to reach the national screening goal of 80% by 2018 and beyond. To inform this work, we conducted a survey of key informants at FQHCs in eight states to determine which evidence-based interventions (EBIs) to promote CRC screening are currently being used, and which implementation strategies are being employed to ensure that the interventions are executed as intended. One hundred and forty-eight FQHCs were invited to participate in the study, and 56 completed surveys were received for a response rate of 38%. Results demonstrated that provider reminder and recall systems were the most commonly used EBIs (44.6%) while the most commonly used implementation strategy was the identification of barriers (84.0%). The mean number of EBIs that were fully implemented at the centers was 2.4 (range 0-7) out of seven. Almost one-quarter of respondents indicated that their FQHCs were not using any EBIs to increase CRC screening. Full implementation of EBIs was correlated with higher CRC screening rates. These findings identify gaps as well as the preferences and needs of FQHCs in selecting and implementing EBIs for CRC screening.

  10. Comparison of dry-textile electrodes for electrical bioimpedance spectroscopy measurements

    NASA Astrophysics Data System (ADS)

    Márquez, J. C.; Seoane, F.; Välimäki, E.; Lindecrantz, K.

    2010-04-01

    Textile Electrodes have been widely studied for biopotentials recordings, specially for monitoring the cardiac activity. Commercially available applications, such as Adistar T-shirt and Textronics Cardioshirt, have proved a good performance for heart rate monitoring and are available worldwide. Textile technology can also be used for Electrical Bioimpedance Spectroscopy measurements enabling home and personalized health monitoring applications however solid ground research about the measurement performance of the electrodes must be done prior to the development of any textile-enabled EBI application. In this work a comparison of the measurement performance of two different types of dry-textile electrodes and manufacturers has been performed against standardized RedDot 3M Ag/AgCl electrolytic electrodes. 4-Electrode, whole body, Ankle-to-Wrist EBI measurements have been taken with the Impedimed spectrometer SFB7 from healthy subjects in the frequency range of 3kHz to 500kHz. Measurements have been taken with dry electrodes at different times to study the influence of the interaction skin-electrode interface on the EBI measurements. The analysis of the obtained complex EBI spectra shows that the measurements performed with textile electrodes produce constant and reliable EBI spectra. Certain deviation can be observed at higher frequencies and the measurements obtained with Textronics and Ag/AgCl electrodes present a better resemblance. Textile technology, if successfully integrated it, may enable the performance of EBI measurements in new scenarios allowing the rising of novel wearable monitoring applications for home and personal care as well as car safety.

  11. BiNChE: a web tool and library for chemical enrichment analysis based on the ChEBI ontology.

    PubMed

    Moreno, Pablo; Beisken, Stephan; Harsha, Bhavana; Muthukrishnan, Venkatesh; Tudose, Ilinca; Dekker, Adriano; Dornfeldt, Stefanie; Taruttis, Franziska; Grosse, Ivo; Hastings, Janna; Neumann, Steffen; Steinbeck, Christoph

    2015-02-21

    Ontology-based enrichment analysis aids in the interpretation and understanding of large-scale biological data. Ontologies are hierarchies of biologically relevant groupings. Using ontology annotations, which link ontology classes to biological entities, enrichment analysis methods assess whether there is a significant over or under representation of entities for ontology classes. While many tools exist that run enrichment analysis for protein sets annotated with the Gene Ontology, there are only a few that can be used for small molecules enrichment analysis. We describe BiNChE, an enrichment analysis tool for small molecules based on the ChEBI Ontology. BiNChE displays an interactive graph that can be exported as a high-resolution image or in network formats. The tool provides plain, weighted and fragment analysis based on either the ChEBI Role Ontology or the ChEBI Structural Ontology. BiNChE aids in the exploration of large sets of small molecules produced within Metabolomics or other Systems Biology research contexts. The open-source tool provides easy and highly interactive web access to enrichment analysis with the ChEBI ontology tool and is additionally available as a standalone library.

  12. Characterization of pitch prepared from pyrolysis fuel oil via electron beam irradiation

    NASA Astrophysics Data System (ADS)

    Kim, Hong Gun; Park, Mira; Kim, Hak-Yong; Kwac, Lee Ku; Shin, Hye Kyoung

    2017-06-01

    Pitch samples were obtained from pyrolysis fuel oil by thermal treatment for 2 h at 300 °C after electron beam irradiation (EBI) treatment and by thermal treatment alone for different temperature of 250 °C, 300 °C, and 350 °C. EBI treatment was found to be an effective treatment for preparing pitch compare to the pitch obtained without EBI treatment. These results were confirmed by Fourier transform infrared spectroscopy (FT-IR) and Carbon-13 nuclear magnetic resonance (13C NMR) analyses, which showed the increase in the intensities of peaks corresponding to aromatic compounds. In the matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) spectra, the amount of components with medium molecular weights in the pitch was found to increase with the temperature; likewise, in the case of the pitch obtained via EBI treatment, we found that the amount of components with higher molecular weight over 1000 (m/v) similarly increased. Further, the thermal stability and carbon yield at 850 °C of the pitch obtained by EBI were greater than those of samples subjected to thermal treatment at 250 and 300 °C.

  13. Respiration monitoring by Electrical Bioimpedance (EBI) Technique in a group of healthy males. Calibration equations.

    NASA Astrophysics Data System (ADS)

    Balleza, M.; Vargas, M.; Kashina, S.; Huerta, M. R.; Delgadillo, I.; Moreno, G.

    2017-01-01

    Several research groups have proposed the electrical impedance tomography (EIT) in order to analyse lung ventilation. With the use of 16 electrodes, the EIT is capable to obtain a set of transversal section images of thorax. In previous works, we have obtained an alternating signal in terms of impedance corresponding to respiration from EIT images. Then, in order to transform those impedance changes into a measurable volume signal a set of calibration equations has been obtained. However, EIT technique is still expensive to attend outpatients in basics hospitals. For that reason, we propose the use of electrical bioimpedance (EBI) technique to monitor respiration behaviour. The aim of this study was to obtain a set of calibration equations to transform EBI impedance changes determined at 4 different frequencies into a measurable volume signal. In this study a group of 8 healthy males was assessed. From obtained results, a high mathematical adjustment in the group calibrations equations was evidenced. Then, the volume determinations obtained by EBI were compared with those obtained by our gold standard. Therefore, despite EBI does not provide a complete information about impedance vectors of lung compared with EIT, it is possible to monitor the respiration.

  14. Searching and Extracting Data from the EMBL-EBI Complex Portal.

    PubMed

    Meldal, Birgit H M; Orchard, Sandra

    2018-01-01

    The Complex Portal ( www.ebi.ac.uk/complexportal ) is an encyclopedia of macromolecular complexes. Complexes are assigned unique, stable IDs, are species specific, and list all participating members with links to an appropriate reference database (UniProtKB, ChEBI, RNAcentral). Each complex is annotated extensively with its functions, properties, structure, stoichiometry, tissue expression profile, and subcellular location. Links to domain-specific databases allow the user to access additional information and enable data searching and filtering. Complexes can be saved and downloaded in PSI-MI XML, MI-JSON, and tab-delimited formats.

  15. First charge breeding results at CARIBU EBIS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kondrashev, S., E-mail: kondrashev@anl.gov; Barcikowski, A., E-mail: kondrashev@anl.gov; Dickerson, C., E-mail: kondrashev@anl.gov

    The Electron Beam Ion Source (EBIS) developed to breed CARIBU radioactive beams at ATLAS is currently in the off-line commissioning stage. The beam commissioning is being performed using a low emittance surface ionization source producing singly-charged cesium ions. The primary goal of the off-line commissioning is the demonstration of high-efficiency charge breeding in the pulsed injection mode. An overview of the final design of the CARIBU EBIS charge breeder, the off-line commissioning installation and the first results on charge breeding of stable cesium ions are presented and discussed.

  16. Selective intestinal decontamination with fluoroquinolones for the prevention of early bacterial infections after liver transplantation.

    PubMed

    San-Juan, Rafael; Aguado, Jose M; Lumbreras, Carlos; Fortun, Jesus; Len, Oscar; Munoz, Patricia; Montejo, Miguel; Moreno, Asunción; Cordero, Elisa; Blanes, Marino; Ramos, Antonio; Torre-Cisneros, Julian; López-Medrano, Francisco; Carratala, Jordi; Moreno, Enrique

    2011-08-01

    The role of selective intestinal decontamination with fluoroquinolones (FQ-SID) in the prevention of early bacterial infections (EBIs) in liver transplant recipients (LTRs) is unknown. We used the online database of the Spanish Network of Infection in Transplantation/Spanish Network for Research in Infectious Diseases, which prospectively analyzed 1010 LTRs from 12 Spanish hospitals from September 2003 to February 2005. We compared the incidence and etiology of EBIs (30 days after transplantation) in 415 LTRs from 4 centers that used FQ-SID (>7 days) and in 595 LTRs from 8 hospitals that did not use FQ-SID. A multivariate logistic regression analysis (including an adjustment for the transplant center factor) was performed to evaluate the potential protective factor of FQ-SID in the development of EBIs. We reported 266 EBI episodes in 252 LTRs (incidence = 24.9%). There were no differences in the incidence of EBIs between patients in the FQ-SID group and patients not in the FQ-SID group [109/415 (26.3%) versus 143/595 (24%), P = 0.9]. Although LTRs who received FQ-SID had a lower incidence of infections due to enteric bacteria (2.7% versus 6.5%, P = 0.007) and a higher incidence of infections due to nonfermenting gram-negative bacilli (6.6% versus 2.6%, P = 0.004), these findings could not be confirmed after an adjustment by the center factor in the multivariate models. We found no significant differences in the incidence of enterococcal infections (3.4% with FQ-SID versus 3.9% without FQ-SID, P = 0.5). Multivariate analysis did not confirm any protective effect of FQ-SID against the development of EBIs by enteric bacteria. In conclusion, FQ-SID does not reduce the incidence of EBIs in LTRs and could be withheld from this group of patients. Copyright © 2011 American Association for the Study of Liver Diseases.

  17. Issues and Challenges in the Design of Culturally Adapted Evidence-Based Interventions

    PubMed Central

    Castro, Felipe González; Barrera, Manuel; Holleran Steiker, Lori K.

    2014-01-01

    This article examines issues and challenges in the design of cultural adaptations that are developed from an original evidence-based intervention (EBI). Recently emerging multistep frameworks or stage models are examined, as these can systematically guide the development of culturally adapted EBIs. Critical issues are also presented regarding whether and how such adaptations may be conducted, and empirical evidence is presented regarding the effectiveness of such cultural adaptations. Recent evidence suggests that these cultural adaptations are effective when applied with certain subcultural groups, although they are less effective when applied with other subcultural groups. Generally, current evidence regarding the effectiveness of cultural adaptations is promising but mixed. Further research is needed to obtain more definitive conclusions regarding the efficacy and effectiveness of culturally adapted EBIs. Directions for future research and recommendations are presented to guide the development of a new generation of culturally adapted EBIs. PMID:20192800

  18. Update and expansion of the HIV/AIDS prevention program archive (HAPPA)

    PubMed Central

    Card, Josefina J.; Cunningham, Shayna D.; Newman, Emily N.; Golden, Rachel E.

    2017-01-01

    Established in 1996 with funding from CDC and NIH, the HIV/AIDS Prevention Program Archive (HAPPA) is now the biggest private sector collection of HIV-related evidence-based behavioral interventions (EBIs). Each EBI in HAPPA has been determined by a distinguished Scientist Expert Panel to have demonstrated efficacy in preventing HIV or its risk-related behaviors in the United States. The multimedia replications kits contain everything that a new site would need to implement an EBI such as a user guide that gives an overview of the program and the evidence of its effectiveness; a facilitator’s manual that gives step-by-step implementation protocols for each session; and session implementation materials referenced in the facilitator's manual such as slides, video clips, participant handouts, activity masters, checklists, and homework assignments for the next session. The program packages also contain evaluation materials such as surveys and questionnaires that were used in the original demonstration of effectiveness and that may be used to re-evaluate the program as implemented in a new setting. Recently, we have expanded HAPPA’s scope to include HIV EBIs developed globally and to include evidence-based structural interventions (effective in modifying the physical, social, cultural, political, economic, legal, and/or policy aspects of the HIV risk environment). This paper describes HAPPA’s procedures for identifying, selecting, acquiring and packaging HIV EBIs. It also provides comprehensive lists of evidence-based HIV behavioral and structural interventions and gives information on how to access EBI program packages for implementation in new settings. PMID:28781971

  19. Three or Four Fractions of 4-5 Gy per Week in Postoperative High-Dose-Rate Brachytherapy for Endometrial Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rovirosa, Angeles, E-mail: rovirosa@clinic.ub.es; Ascaso, Carlos; Sanchez-Reyes, Alberto

    2011-10-01

    Purpose: To evaluate the results of high-dose-rate brachytherapy (HDRBT) using a schedule of three or four fractions per week, when possible, in 89 patients on local control and toxicity in postoperative treatment of endometrial carcinoma. The effect of the overall HDRBT treatment time (OTT) on toxicity was also evaluated. Patients and Methods: Federation Internationale de Gynecologie Obstetrique Stage: 24 IB, 45 IC, 4 IIA, 6 IIB, 4 IIIA, 2 IIIB, and 4 IIIC. Radiotherapy: Group 1-67 of 89 patients received external beam irradiation (EBI; 44-50 Gy) plus HDRBT (3 fractions of 4-6 Gy); Group 2-22 of 89 patients received HDRBTmore » alone (6 fractions of 4-5 Gy). OTT: Group 1-HDRBT was completed in a median of 5 days in 32 patients and in >5 days in 35; Group 2-HDRBT was completed in <15 days in 11 patients and in {>=}16 days in 11. Toxicity was evaluated using Radiation Therapy Oncology Group scores and the bioequivalent dose (BED) study was performed in vaginal mucosa surface. Statistics included Student's t test, chi-square test, and receiving operator curves. Results: With a mean follow-up of 31 months (range, 6-70), 1 of 89 patients had vaginal relapse. Early toxicity appeared in 8 of 89 (9%) patients and was resolved. Late toxicity appeared in 13/89 (14%): vaginal nine Grade 1, three Grade 2, one Grade 4; bladder two Grade 2; rectal three Grade 1, one Grade 2. No differences were found in relation to OTT in Groups 1 and 2. Mean BED was 88.48 Gy in Group 1 and 165.28 Gy in Group 2. Cases with Grade 2 late vaginal toxicity received >75 Gy after EBI and >165 Gy in Group 2. Conclusions: Three fractions of 4-5 Gy in 3-5 days after EBI or 6 fractions in <15 days in patients receiving HDRBT alone was a safe treatment in relation to toxicity and local control. Vaginal surface BED less than 75 Gy after EBI and less than 160 Gy in HDRBT alone may be safe to avoid G2 toxicity.« less

  20. The ChEBI reference database and ontology for biologically relevant chemistry: enhancements for 2013.

    PubMed

    Hastings, Janna; de Matos, Paula; Dekker, Adriano; Ennis, Marcus; Harsha, Bhavana; Kale, Namrata; Muthukrishnan, Venkatesh; Owen, Gareth; Turner, Steve; Williams, Mark; Steinbeck, Christoph

    2013-01-01

    ChEBI (http://www.ebi.ac.uk/chebi) is a database and ontology of chemical entities of biological interest. Over the past few years, ChEBI has continued to grow steadily in content, and has added several new features. In addition to incorporating all user-requested compounds, our annotation efforts have emphasized immunology, natural products and metabolites in many species. All database entries are now 'is_a' classified within the ontology, meaning that all of the chemicals are available to semantic reasoning tools that harness the classification hierarchy. We have completely aligned the ontology with the Open Biomedical Ontologies (OBO) Foundry-recommended upper level Basic Formal Ontology. Furthermore, we have aligned our chemical classification with the classification of chemical-involving processes in the Gene Ontology (GO), and as a result of this effort, the majority of chemical-involving processes in GO are now defined in terms of the ChEBI entities that participate in them. This effort necessitated incorporating many additional biologically relevant compounds. We have incorporated additional data types including reference citations, and the species and component for metabolites. Finally, our website and web services have had several enhancements, most notably the provision of a dynamic new interactive graph-based ontology visualization.

  1. The Roles of System and Organizational Leadership in System-Wide Evidence-Based Intervention Sustainment: A Mixed-Method Study.

    PubMed

    Aarons, Gregory A; Green, Amy E; Trott, Elise; Willging, Cathleen E; Torres, Elisa M; Ehrhart, Mark G; Roesch, Scott C

    2016-11-01

    If evidence-based interventions (EBIs) are not sustained, investments are wasted and public health impact is limited. Leadership has been suggested as a key determinant of implementation and sustainment; however, little empirical work has examined this factor. This mixed-methods study framed using the Exploration, Preparation, Implementation, Sustainment (EPIS) conceptual framework examines leadership in both the outer service system context and inner organizational context in eleven system-wide implementations of the same EBI across two U.S. states and 87 counties. Quantitative data at the outer context (i.e., system) and inner context (i.e., team) levels demonstrated that leadership predicted future sustainment and differentiated between sites with full, partial, or no sustainment. In the outer context positive sustainment leadership was characterized as establishing a project's mission and vision, early and continued planning for sustainment, realistic project plans, and having alternative strategies for project survival. Inner context frontline transformational leadership predicted sustainment while passive-avoidant leadership predicted non-sustainment. Qualitative results found that sustainment was associated with outer context leadership characterized by engagement in ongoing supportive EBI championing, marketing to stakeholders; persevering in these activities; taking action to institutionalize the EBI with funding, contracting, and system improvement plans; and fostering ongoing collaboration between stakeholders at state and county, and community stakeholder levels. For frontline leadership the most important activities included championing the EBI and providing practical support for service providers. There was both convergence and expansion that identified unique contributions of the quantitative and qualitative methods. Greater attention to leadership in both the outer system and inner organizational contexts is warranted to enhance EBI implementation and sustainment.

  2. The Roles of System and Organizational Leadership in System-Wide Evidence-Based Intervention Sustainment: A Mixed-Method Study

    PubMed Central

    Aarons, Gregory A.; Green, Amy E.; Trott, Elise; Willging, Cathleen E.; Torres, Elisa M.; Ehrhart, Mark G.; Roesch, Scott C.

    2017-01-01

    If evidence-based interventions (EBIs) are not sustained, investments are wasted and public health impact is limited. Leadership has been suggested as a key determinant of implementation and sustainment; however, little empirical work has examined this factor. This mixed-methods study framed using the Exploration, Preparation, Implementation, Sustainment (EPIS) conceptual framework examines leadership in both the outer service system context and inner organizational context in eleven system-wide implementations of the same EBI across two U.S. states and 87 counties. Quantitative data at the outer context (i.e., system) and inner context (i.e., team) levels demonstrated that leadership predicted future sustainment and differentiated between sites with full, partial, or no sustainment. In the outer context positive sustainment leadership was characterized as establishing a project’s mission and vision, early and continued planning for sustainment, realistic project plans, and having alternative strategies for project survival. Inner context frontline transformational leadership predicted sustainment while passive-avoidant leadership predicted non-sustainment. Qualitative results found that sustainment was associated with outer context leadership characterized by engagement in ongoing supportive EBI championing, marketing to stakeholders; persevering in these activities; taking action to institutionalize the EBI with funding, contracting, and system improvement plans; and fostering ongoing collaboration between stakeholders at state and county, and community stakeholder levels. For frontline leadership the most important activities included championing the EBI and providing practical support for service providers. There was both convergence and expansion that identified unique contributions of the quantitative and qualitative methods. Greater attention to leadership in both the outer system and inner organizational contexts is warranted to enhance EBI implementation and sustainment. PMID:27439504

  3. Run 16 Tandem gold performance in the injectors and possible improvement with AGS type 6:3:1 bunch merge in the Booster

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeno, Keith

    2016-10-21

    During Run 16 the Tandem was used as the Gold pre-injector for a brief time so that RHIC could continue running while EBIS was down for repairs. Given the time constraints, the setup was largely derived from the EBIS Au setup. The EBIS Au setup used a 4:2:1 bunch merge in the Booster and a 12:6:2 bunch merge in the AGS.1 This note will describe the Tandem Au setup and compare it to that used for EBIS Au. The bunch merge in the Booster for Tandem Au did not work well, and it seems likely that the performance would’ve beenmore » significantly better if it did. An AGS type 6:3:1 merge in the Booster is described which might improve matters.2 Somewhat speculative estimates for the AGS bunch intensity and emittance, if that merge were successful in reducing the Booster extraction emittance to EBIS Au levels, are also given for several potential setups. Using 6 Booster loads from the Tandem, the AGS bunch intensity at extraction reached about 2.5e9 ions with a longitudinal emittance (ε) of about 0.59 eV·s/n.3 Using 12 Booster loads from EBIS, the peak bunch intensity and ε was about 3.1e9 ions and 0.75 eV·s/n, respectively. A 6.4 sec supercycle was used for both at the time, but the Tandem Au supercycle (barring any potential issues with Tandem) could probably have been reduced to about 4.6 sec.« less

  4. Exploring Implementation and Fidelity of Evidence-Based Behavioral Interventions for HIV Prevention: Lessons Learned From the Focus on Kids Diffusion Case Study

    PubMed Central

    Galbraith, Jennifer S.; Stanton, Bonita; Boekeloo, Bradley; King, Winifred; Desmond, Sharon; Howard, Donna; Black, Maureen M.; Carey, James W.

    2014-01-01

    Evidence-based interventions (EBIs) are used in public health to prevent HIV infection among youth and other groups. EBIs include core elements, features that are thought to be responsible for the efficacy of interventions. The authors evaluate experiences of organizations that adopted an HIV-prevention EBI, Focus on Kids (FOK), and their fidelity to the intervention’s eight core elements. A cross-sectional telephone survey was administered to 34 staff members from organizations that had previously implemented FOK. Questions assessed how the organization adhered to, adapted, dropped, or altered the intervention. None of the organizations implemented all eight core elements. This study underscores the importance for HIV intervention researchers to clearly identify and describe core elements. More effort is needed to reflect the constraints practitioners face in nonresearch settings. To ensure intervention effectiveness, additional research and technical assistance are needed to help organizations implement HIV prevention EBIs with fidelity. PMID:18445739

  5. Synthesizing Marketing, Community Engagement, and Systems Science Approaches for Advancing Translational Research.

    PubMed

    Kneipp, Shawn M; Leeman, Jennifer; McCall, Pamela; Hassmiller-Lich, Kristen; Bobashev, Georgiy; Schwartz, Todd A; Gilmore, Robert; Riggan, Scott; Gil, Benjamin

    2015-01-01

    The adoption and implementation of evidence-based interventions (EBIs) are the goals of translational research; however, potential end-users' perceptions of an EBI value have contributed to low rates of adoption. In this article, we describe our application of emerging dissemination and implementation science theoretical perspectives, community engagement, and systems science principles to develop a novel EBI dissemination approach. Using consumer-driven, graphics-rich simulation, the approach demonstrates predicted implementation effects on health and employment outcomes for socioeconomically disadvantaged women at the local level and is designed to increase adoption interest of county program managers accountable for improving these outcomes in their communities.

  6. Contracting and Procurement for Evidence-Based Interventions in Public-Sector Human Services: A Case Study.

    PubMed

    Willging, Cathleen E; Aarons, Gregory A; Trott, Elise M; Green, Amy E; Finn, Natalie; Ehrhart, Mark G; Hecht, Debra B

    2016-09-01

    Sustainment of evidence-based interventions (EBIs) in human services depends on the inner context of community-based organizations (CBOs) that provide services and the outer context of their broader environment. Increasingly, public officials are experimenting with contracting models from for-profit industries to procure human services. In this case study, we conducted qualitative interviews with key government and CBO stakeholders to examine implementation of the Best Value-Performance Information Procurement System to contract for EBIs in a child welfare system. Findings suggest that stakeholder relationships may be compromised when procurement disregards local knowledge, communication, collaboration, and other factors supporting EBIs and public health initiatives.

  7. Tuning of Schottky barrier height of Al/n-Si by electron beam irradiation

    NASA Astrophysics Data System (ADS)

    Vali, Indudhar Panduranga; Shetty, Pramoda Kumara; Mahesha, M. G.; Petwal, V. C.; Dwivedi, Jishnu; Choudhary, R. J.

    2017-06-01

    The effect of electron beam irradiation (EBI) on Al/n-Si Schottky diode has been studied by I-V characterization at room temperature. The behavior of the metal-semiconductor (MS) interface is analyzed by means of variations in the MS contact parameters such as, Schottky barrier height (ΦB), ideality factor (n) and series resistance (Rs). These parameters were found to depend on the EBI dose having a fixed incident beam of energy 7.5 MeV. At different doses (500, 1000, 1500 kGy) of EBI, the Schottky contacts were prepared and extracted their contact parameters by applying thermionic emission and Cheung models. Remarkably, the tuning of ΦB was observed as a function of EBI dose. The improved n with increased ΦB is seen for all the EBI doses. As a consequence of which the thermionic emission is more favored. However, the competing transport mechanisms such as space charge limited emission, tunneling and tunneling through the trap states were ascribed due to n > 1. The analysis of XPS spectra have shown the presence of native oxide and increased radiation induced defect states. The thickness variation in the MS interface contributing to Schottky contact behavior is discussed. This study explains a new technique to tune Schottky contact parameters by metal deposition on the electron beam irradiated n-Si wafers.

  8. PREFACE: The ninth International Symposium on Electron Beam Ion Sources and Traps and Their Applications, 15 17 April 2004

    NASA Astrophysics Data System (ADS)

    Nakamura, Nobuyuki; Ohtani, Shunsuke

    2004-01-01

    The ninth International Symposium on Electron Beam Ion Sources and Traps and Their Applications — EBIS/T 2004 was held at the Tokyo Metropolitan University (TMU), 15-17 April 2004. There were about 40 participants and about 30 papers presented. The meeting has shown the remarkable progress in science and technology with the EBIS/T machines. In this meeting, besides the normal presentations related to the EBIS/T works, a special session was organized on the last day which was dedicated to Professors N Kobayashi and K Okuno, who have contributed to the EBIS/T development and to the physics of highly charged ions (HCI), to mark their retirement from the TMU in March 2004. In the evening of the first day, there was a laboratory tour where the participants enjoyed seeing the Tokyo EBIT facility and also a beer party in a small hall next to the laboratory. The banquet was held in a traditional Japanese restaurant in a village under Mt Takao with the Japanese meals and performances, after seeing the HCI-research activities in the TMU. The next EBIS/T symposium will be held in Heidelberg in the summer of 2007 as a satellite meeting of XXV ICPEAC. We are looking forward to the next exciting meeting there. Finally, we thank all of TMU staffs and students for their help during the meeting.

  9. Recent charge-breeding developments with EBIS/T devices (invited).

    PubMed

    Schwarz, S; Lapierre, A

    2016-02-01

    Short breeding times, narrow charge state distributions, low background, high efficiency, and the flexible time structure of the ejected low-emittance ion pulses are among the most attractive features of electron beam ion source or trap (EBIS/T) based charge breeders. Significant progress has been made to further improve these properties: Several groups are working to increase current densities towards 10(3) or even 10(4) A/cm(2). These current densities will become necessary to deliver high charge states of heavy nuclei in a short time and/or provide sufficient space-charge capacity to handle high-current ion beams in next-generation rare-isotope beam (RIB) facilities. Efficient capture of continuous beams, attractive because of its potential of handling highest-current ion beams, has become possible with the development of high-density electron beams of >1 A. Requests for the time structure of the charge bred ion pulse range from ultra-short pulses to quasi-continuous beams. Progress is being made on both ends of this spectrum, by either dividing the extracted charge in many pulse-lets, adjusting the extraction potential for a near-uniform long pulse, or adding dedicated devices to spread the ion bunches delivered from the EBIS/T in time. Advances in EBIS/T charge state breeding are summarized, including recent results with NSCL's ReA EBIS/T charge breeder.

  10. Recent charge-breeding developments with EBIS/T devices (invited)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwarz, S., E-mail: schwarz@nscl.msu.edu; Lapierre, A.

    Short breeding times, narrow charge state distributions, low background, high efficiency, and the flexible time structure of the ejected low-emittance ion pulses are among the most attractive features of electron beam ion source or trap (EBIS/T) based charge breeders. Significant progress has been made to further improve these properties: Several groups are working to increase current densities towards 10{sup 3} or even 10{sup 4} A/cm{sup 2}. These current densities will become necessary to deliver high charge states of heavy nuclei in a short time and/or provide sufficient space-charge capacity to handle high-current ion beams in next-generation rare-isotope beam (RIB) facilities.more » Efficient capture of continuous beams, attractive because of its potential of handling highest-current ion beams, has become possible with the development of high-density electron beams of >1 A. Requests for the time structure of the charge bred ion pulse range from ultra-short pulses to quasi-continuous beams. Progress is being made on both ends of this spectrum, by either dividing the extracted charge in many pulse-lets, adjusting the extraction potential for a near-uniform long pulse, or adding dedicated devices to spread the ion bunches delivered from the EBIS/T in time. Advances in EBIS/T charge state breeding are summarized, including recent results with NSCL’s ReA EBIS/T charge breeder.« less

  11. A high-compression electron gun for C6+ production: concept, simulations and mechanical design

    NASA Astrophysics Data System (ADS)

    Mertzig, Robert; Breitenfeldt, M.; Mathot, S.; Pitters, J.; Shornikov, A.; Wenander, F.

    2017-07-01

    In this paper we report on simulations and the mechanical design of a high-compression electron gun for an Electron Beam Ion Source (EBIS) dedicated for production of high intensity and high repetition rate pulses of bare carbon ions for injection into linac-based hadron therapy facilities. The gun is presently under construction at CERN to be retrofitted into the TwinEBIS test bench for experimental studies. We describe the design constraints, show results of numeric simulations and report on the mechanical design featuring several novel ideas. The reported design makes use of combined-function units with reduced number of mechanical joints that were carefully controlled and tuned during the manufacturing phase. The simulations addressed a wide range of topics including the influence of thermal effects, focusing optics, symmetry-breaking misalignments and injection into a full 5 T field.

  12. Dynamic Pattern Formation in Electron-Beam-Induced Etching [Emergent formation of dynamic topographic patterns in electron beam induced etching

    DOE PAGES

    Martin, Aiden A.; Bahm, Alan; Bishop, James; ...

    2015-12-15

    Here, we report highly ordered topographic patterns that form on the surface of diamond, span multiple length scales, and have a symmetry controlled by the precursor gas species used in electron-beam-induced etching (EBIE). The pattern formation dynamics reveals an etch rate anisotropy and an electron energy transfer pathway that is overlooked by existing EBIE models. Therefore, we, modify established theory such that it explains our results and remains universally applicable to EBIE. Furthermore, the patterns can be exploited in controlled wetting, optical structuring, and other emerging applications that require nano- and microscale surface texturing of a wide band-gap material.

  13. Contracting and Procurement for Evidence-Based Interventions in Public-Sector Human Services: A Case Study

    PubMed Central

    Willging, Cathleen E.; Aarons, Gregory A.; Trott, Elise M.; Green, Amy E.; Finn, Natalie; Ehrhart, Mark G.; Hecht, Debra B.

    2016-01-01

    Sustainment of evidence-based interventions (EBIs) in human services depends on the inner context of community-based organizations (CBOs) that provide services and the outer context of their broader environment. Increasingly, public officials are experimenting with contracting models from for-profit industries to procure human services. In this case study, we conducted qualitative interviews with key government and CBO stakeholders to examine implementation of the Best Value-Performance Information Procurement System to contract for EBIs in a child welfare system. Findings suggest that stakeholder relationships may be compromised when procurement disregards local knowledge, communication, collaboration, and other factors supporting EBIs and public health initiatives. PMID:26386977

  14. Is Personalized Learning the Future of School?

    ERIC Educational Resources Information Center

    Paz-Albo, Jesús

    2017-01-01

    This article describes an innovative teaching approach that can offer the changes needed for school improvement. When entering an Education: Basic and Interactive (EBI) classroom, one will see students focused on accomplishing self-guided tasks and eager to move on to the next challenge in their self-paced learning. The EBI Project described here…

  15. The European Bioinformatics Institute's data resources: towards systems biology.

    PubMed

    Brooksbank, Catherine; Cameron, Graham; Thornton, Janet

    2005-01-01

    Genomic and post-genomic biological research has provided fine-grain insights into the molecular processes of life, but also threatens to drown biomedical researchers in data. Moreover, as new high-throughput technologies are developed, the types of data that are gathered en masse are diversifying. The need to collect, store and curate all this information in ways that allow its efficient retrieval and exploitation is greater than ever. The European Bioinformatics Institute's (EBI's) databases and tools have evolved to meet the changing needs of molecular biologists: since we last wrote about our services in the 2003 issue of Nucleic Acids Research, we have launched new databases covering protein-protein interactions (IntAct), pathways (Reactome) and small molecules (ChEBI). Our existing core databases have continued to evolve to meet the changing needs of biomedical researchers, and we have developed new data-access tools that help biologists to move intuitively through the different data types, thereby helping them to put the parts together to understand biology at the systems level. The EBI's data resources are all available on our website at http://www.ebi.ac.uk.

  16. The European Bioinformatics Institute's data resources: towards systems biology

    PubMed Central

    Brooksbank, Catherine; Cameron, Graham; Thornton, Janet

    2005-01-01

    Genomic and post-genomic biological research has provided fine-grain insights into the molecular processes of life, but also threatens to drown biomedical researchers in data. Moreover, as new high-throughput technologies are developed, the types of data that are gathered en masse are diversifying. The need to collect, store and curate all this information in ways that allow its efficient retrieval and exploitation is greater than ever. The European Bioinformatics Institute's (EBI's) databases and tools have evolved to meet the changing needs of molecular biologists: since we last wrote about our services in the 2003 issue of Nucleic Acids Research, we have launched new databases covering protein–protein interactions (IntAct), pathways (Reactome) and small molecules (ChEBI). Our existing core databases have continued to evolve to meet the changing needs of biomedical researchers, and we have developed new data-access tools that help biologists to move intuitively through the different data types, thereby helping them to put the parts together to understand biology at the systems level. The EBI's data resources are all available on our website at http://www.ebi.ac.uk. PMID:15608238

  17. The effect of the PROSPER partnership model on cultivating local stakeholder knowledge of evidence-based programs: a five-year longitudinal study of 28 communities.

    PubMed

    Crowley, D Max; Greenberg, Mark T; Feinberg, Mark E; Spoth, Richard L; Redmond, Cleve R

    2012-02-01

    A substantial challenge in improving public health is how to facilitate the local adoption of evidence-based interventions (EBIs). To do so, an important step is to build local stakeholders' knowledge and decision-making skills regarding the adoption and implementation of EBIs. One EBI delivery system, called PROSPER (PROmoting School-community-university Partnerships to Enhance Resilience), has effectively mobilized community prevention efforts, implemented prevention programming with quality, and consequently decreased youth substance abuse. While these results are encouraging, another objective is to increase local stakeholder knowledge of best practices for adoption, implementation and evaluation of EBIs. Using a mixed methods approach, we assessed local stakeholder knowledge of these best practices over 5 years, in 28 intervention and control communities. Results indicated that the PROSPER partnership model led to significant increases in expert knowledge regarding the selection, implementation, and evaluation of evidence-based interventions. Findings illustrate the limited programming knowledge possessed by members of local prevention efforts, the difficulty of complete knowledge transfer, and highlight one method for cultivating that knowledge.

  18. Developing a Policy Flight Simulator to Facilitate the Adoption of an Evidence-Based Intervention

    PubMed Central

    Yu, Zhongyuan; Hirschman, Karen B.; Pepe, Kara; Pauly, Mark V.; Naylor, Mary D.; Rouse, William B.

    2018-01-01

    While the use of evidence-based interventions (EBIs) has been advocated by the medical research community for quite some time, uptake of these interventions by healthcare providers has been slow. One possible explanation is that it is challenging for providers to estimate impacts of a specific EBI on their particular organization. To address that concern, we developed and evaluated a type of simulation called a policy flight simulator to determine if it could improve the adoption decision about a specific EBI, the transitional care model (TCM). The TCM uses an advanced practice nurse-led model of care to transition older adults with multiple chronic conditions from a hospitalization to home. An evaluation by a National Advisory Committee, made up of senior representatives from various stakeholders in the U.S. healthcare system, found the policy flight simulator to be a useful tool that has the potential to better inform adoption decisions. This paper describes the simulation development effort and documents lessons learned that may be useful to the healthcare modeling community and those interested in using simulation to support decisions based on EBIs. PMID:29805921

  19. Extended brief intervention to address alcohol misuse in people with mild to moderate intellectual disabilities living in the community (EBI-ID): study protocol for a randomised controlled trial.

    PubMed

    Kouimtsidis, Christos; Fodor-Wynne, Lucy; Scior, Katrina; Hunter, Rachael; Baio, Gianluca; Pezzoni, Vittoria; Hassiotis, Angela

    2015-03-25

    There is some evidence that people with intellectual disabilities who live in the community are exposed to the same risks of alcohol use as the rest of the population. Various interventions have been evaluated in the general population to tackle hazardous or harmful drinking and alcohol dependence, but the literature evaluating interventions is very limited regarding intellectual disabilities. The National Institute for Health and Clinical Excellence recommends that brief and extended brief interventions be used to help young persons and adults who have screened as positive for hazardous and harmful drinking. The objective of this trial is to investigate the feasibility of adapting and delivering an extended brief intervention (EBI) to persons with mild/moderate intellectual disability who live in the community and whose level of drinking is harmful or hazardous. The study has three stages, which include the adaptation of the Extended Brief Intervention (EBI) for people with intellectual disability, a single blind, randomised controlled trial of an individual Extended Brief Intervention to test the feasibility of the intervention, and a qualitative study that will assess the perceived acceptability and usefulness of the intervention. Fifty participants in total will be recruited from community intellectual disability services and social care or third sector organisations. The main outcome is a reduction in alcohol consumption measured by the Alcohol Use Disorders Identification Test. Alcohol misuse is a relatively under-researched mental health problem in people with intellectual disabilities. Therefore, the study addresses both diagnostic issues and the delivery of a simple first stage intervention, which is available to the population of average intelligence and young persons in particular. The findings from the study will guide the preparation of a large-scale study to test whether this treatment is clinically and cost-effective in this population. ISRCTN58783633 (19 December 2013).

  20. Implementing referral to an electronic alcohol brief advice website in primary healthcare: results from the ODHIN implementation trial

    PubMed Central

    Bendtsen, Preben; Müssener, Ulrika; Karlsson, Nadine; López-Pelayo, Hugo; Palacio-Vieira, Jorge; Colom, Joan; Gual, Antoni; Reynolds, Jillian; Wallace, Paul; Segura, Lidia; Anderson, Peter

    2016-01-01

    Objectives The objective of the present study was to explore whether the possibility of offering facilitated access to an alcohol electronic brief intervention (eBI) instead of delivering brief face-to-face advice increased the proportion of consulting adults who were screened and given brief advice. Design The study was a 12-week implementation study. Sixty primary healthcare units (PHCUs) in 5 jurisdictions (Catalonia, England, the Netherlands, Poland and Sweden) were asked to screen adults who attended the PHCU for risky drinking. Setting A total of 120 primary healthcare centres from 5 jurisdictions in Europe. Participants 746 individual providers (general practitioners, nurses or other professionals) participated in the study. Primary outcome Change in the proportion of patients screened and referred to eBI comparing a baseline 4-week preimplementation period with a 12-week implementation period. Results The possibility of referring patients to the eBI was not found to be associated with any increase in the proportion of patients screened. However, it was associated with an increase in the proportion of screen-positive patients receiving brief advice from 70% to 80% for the screen-positive sample as a whole (p<0.05), mainly driven by a significant increase in brief intervention rates in England from 87% to 96% (p<0.01). The study indicated that staff displayed a low level of engagement in this new technology. Staff continued to offer face-to-face advice to a larger proportion of patients (54%) than referral to eBI (38%). In addition, low engagement was seen among the referred patients; on average, 18% of the patients logged on to the website with a mean log-on rate across the different countries between 0.58% and 36.95%. Conclusions Referral to eBI takes nearly as much time as brief oral advice and might require more introduction and training before staff are comfortable with referring to eBI. Trial registration number NCT01501552; Post-results. PMID:27311902

  1. Evaluation and Cross-Comparison of Lexical Entities of Biological Interest (LexEBI)

    PubMed Central

    Rebholz-Schuhmann, Dietrich; Kim, Jee-Hyub; Yan, Ying; Dixit, Abhishek; Friteyre, Caroline; Hoehndorf, Robert; Backofen, Rolf; Lewin, Ian

    2013-01-01

    Motivation Biomedical entities, their identifiers and names, are essential in the representation of biomedical facts and knowledge. In the same way, the complete set of biomedical and chemical terms, i.e. the biomedical “term space” (the “Lexeome”), forms a key resource to achieve the full integration of the scientific literature with biomedical data resources: any identified named entity can immediately be normalized to the correct database entry. This goal does not only require that we are aware of all existing terms, but would also profit from knowing all their senses and their semantic interpretation (ambiguities, nestedness). Result This study compiles a resource for lexical terms of biomedical interest in a standard format (called “LexEBI”), determines the overall number of terms, their reuse in different resources and the nestedness of terms. LexEBI comprises references for protein and gene entries and their term variants and chemical entities amongst other terms. In addition, disease terms have been identified from Medline and PubmedCentral and added to LexEBI. Our analysis demonstrates that the baseforms of terms from the different semantic types show only little polysemous use. Nonetheless, the term variants of protein and gene names (PGNs) frequently contain species mentions, which should have been avoided according to protein annotation guidelines. Furthermore, the protein and gene entities as well as the chemical entities, both do comprise enzymes leading to hierarchical polysemy, and a large portion of PGNs make reference to a chemical entity. Altogether, according to our analysis based on the Medline distribution, 401,869 unique PGNs in the documents contain a reference to 25,022 chemical entities, 3,125 disease terms or 1,576 species mentions. Conclusion LexEBI delivers the complete biomedical and chemical Lexeome in a standardized representation (http://www.ebi.ac.uk/Rebholz-srv/LexEBI/). The resource provides the disease terms as open source content, and fully interlinks terms across resources. PMID:24124474

  2. Identification and characterisation of the IL-27 p28 subunits in fish: Cloning and comparative expression analysis of two p28 paralogues in Atlantic salmon Salmo salar.

    PubMed

    Husain, Mansourah; Martin, Samuel A M; Wang, Tiehui

    2014-11-01

    Interleukin (IL)-27 is an IL-6/IL-12 family member with pro-inflammatory and anti-inflammatory properties. It is a heterodimeric cytokine composed of an α-chain p28 and a β-chain Ebi3 (Epstein-Barr virus induce gene 3). The p28 subunit can also be secreted as a monomer and function as IL-30 that acts as an inhibitor of IL-27 signalling. At present, the p28 gene has only been described in mammals. Thus, for the first time outwith mammals, we have identified seven p28 molecules in six divergent teleost fish species, Atlantic salmon, two cichlids, two cyprinids and a yellowtail. The fish p28 molecules have higher similarities to mammalian p28 than other IL-6/12 family members. Critical residues involved in the interaction with Ebi3 and the receptor gp130 are highly conserved. The prediction that these are true orthologues is supported by phylogenetic and synteny analysis. Two p28 paralogues (p28a and p28b) sharing 72% aa identity have been identified and characterised in Atlantic salmon. There are multiple upstream ATGs in the 5'-UTR and ATTTA motifs in the 3'-UTR of both cDNA sequences, suggesting regulation at the post-transcriptional and translational level. Both salmon p28 genes are highly expressed in immune relevant tissues, such as thymus, gills, spleen and head kidney. Conversely salmon Ebi3 is highly expressed in other organs, such as liver and caudal kidney. The expression of p28 but not Ebi3 was induced by PAMPs and recombinant cytokines in head kidney cells, and in spleen by Poly I:C challenge in vivo. The dissociation of the expression and modulation of p28 and Ebi3 suggest that both p28 and Ebi3 may be secreted alone or with other partners. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Three or four fractions of 4-5 Gy per week in postoperative high-dose-rate brachytherapy for endometrial carcinoma.

    PubMed

    Rovirosa, Angeles; Ascaso, Carlos; Sánchez-Reyes, Alberto; Herreros, Antonio; Abellana, Rosa; Pahisa, Jaume; Lejarcegui, Jose Antonio; Biete, Albert

    2011-10-01

    To evaluate the results of high-dose-rate brachytherapy (HDRBT) using a schedule of three or four fractions per week, when possible, in 89 patients on local control and toxicity in postoperative treatment of endometrial carcinoma. The effect of the overall HDRBT treatment time (OTT) on toxicity was also evaluated. Fédération Internationale de Gynécologie Obstétrique Stage: 24 IB, 45 IC, 4 IIA, 6 IIB, 4 IIIA, 2 IIIB, and 4 IIIC. Radiotherapy: Group 1-67 of 89 patients received external beam irradiation (EBI; 44-50 Gy) plus HDRBT (3 fractions of 4-6 Gy); Group 2-22 of 89 patients received HDRBT alone (6 fractions of 4-5 Gy). OTT: Group 1-HDRBT was completed in a median of 5 days in 32 patients and in >5 days in 35; Group 2-HDRBT was completed in <15 days in 11 patients and in ≥16 days in 11. Toxicity was evaluated using Radiation Therapy Oncology Group scores and the bioequivalent dose (BED) study was performed in vaginal mucosa surface. Statistics included Student's t test, chi-square test, and receiving operator curves. With a mean follow-up of 31 months (range, 6-70), 1 of 89 patients had vaginal relapse. Early toxicity appeared in 8 of 89 (9%) patients and was resolved. Late toxicity appeared in 13/89 (14%): vaginal nine Grade 1, three Grade 2, one Grade 4; bladder two Grade 2; rectal three Grade 1, one Grade 2. No differences were found in relation to OTT in Groups 1 and 2. Mean BED was 88.48 Gy in Group 1 and 165.28 Gy in Group 2. Cases with Grade 2 late vaginal toxicity received >75 Gy after EBI and >165 Gy in Group 2. Three fractions of 4-5 Gy in 3-5 days after EBI or 6 fractions in <15 days in patients receiving HDRBT alone was a safe treatment in relation to toxicity and local control. Vaginal surface BED less than 75 Gy after EBI and less than 160 Gy in HDRBT alone may be safe to avoid G2 toxicity. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Validation of the Chinese Version of the Epistemic Beliefs Inventory Using Confirmatory Factor Analysis

    ERIC Educational Resources Information Center

    Wang, Xihui; Zhang, Zhidong; Zhang, Xiuying; Hou, Dadong

    2013-01-01

    The Epistemic Beliefs Inventory (EBI), as a theory-based and empirically validated instrument, was originally developed and widely used in the North American context. Through a strict translation procedure the authors translated the EBI into Chinese, and then administered it to 451 students in 7 universities in mainland China. The construct…

  5. Children's Executive Functions: Are They Poorer after Very Early Brain Insult

    ERIC Educational Resources Information Center

    Anderson, Vicki; Spencer-Smith, Megan; Coleman, Lee; Anderson, Peter; Williams, Jackie; Greenham, Mardee; Leventer, Richard J.; Jacobs, Rani

    2010-01-01

    Traditionally early brain insult (EBI) has been considered to have better outcome than later injury, consistent with the notion that the young brain is flexible and able to reorganize. Recent research findings question this view, suggesting that EBI might lead to poorer outcome than brain insult at any other age. Exploring this early vulnerability…

  6. Evidence Based Interventions: An Examination of Pre-Service Training, Professional Development, and Classroom Implementation

    ERIC Educational Resources Information Center

    Hoover, Kristin Nicole

    2013-01-01

    The purpose of the study was to examine the relationship between EBI training for special education teachers and their practice of classroom interventions for children with an autism spectrum disorder (ASD). Evaluating the usage of EBIs in the classroom is imperative because of the many obligations educators have to uphold federal compliances…

  7. The Sophomore RA Experience: An Examination of Job Satisfaction, Turnover Intentions, and RA Self-Efficacy

    ERIC Educational Resources Information Center

    Brandt Brecheisen, Shannon M.

    2014-01-01

    The purpose of this national, quantitative study was to (1) provide psychometrics for the ACUHO-I/EBI RA Survey, a joint project between between Educational Benchmarking, Inc (EBI) and The Association of College and University Housing Officers--International (ACUHO-I), and (2) explore the sophomore resident assistant (RA) experience. This study…

  8. The European Bioinformatics Institute's data resources 2014.

    PubMed

    Brooksbank, Catherine; Bergman, Mary Todd; Apweiler, Rolf; Birney, Ewan; Thornton, Janet

    2014-01-01

    Molecular Biology has been at the heart of the 'big data' revolution from its very beginning, and the need for access to biological data is a common thread running from the 1965 publication of Dayhoff's 'Atlas of Protein Sequence and Structure' through the Human Genome Project in the late 1990s and early 2000s to today's population-scale sequencing initiatives. The European Bioinformatics Institute (EMBL-EBI; http://www.ebi.ac.uk) is one of three organizations worldwide that provides free access to comprehensive, integrated molecular data sets. Here, we summarize the principles underpinning the development of these public resources and provide an overview of EMBL-EBI's database collection to complement the reviews of individual databases provided elsewhere in this issue.

  9. The Role of Collaborations in Sustaining an Evidence-Based Intervention to Reduce Child Neglect

    PubMed Central

    Green, Amy E.; Trott, Elise; Willging, Cathleen E.; Finn, Natalie K.; Ehrhart, Mark G.; Aarons, Gregory A.

    2016-01-01

    Child neglect is the most prevalent form of child maltreatment and represents 79.5% of open child-welfare cases. A recent study found the evidence-based intervention (EBI) SafeCare® (SC) to significantly reduce child neglect recidivism rates. To fully capitalize on the effectiveness of such EBIs, service systems must engage in successful implementation and sustainment; however, little is known regarding what factors influence EBI sustainment. Collaborations among stakeholders are suggested as a means for facilitating EBI implementation and sustainment. This study combines descriptive quantitative survey data with qualitative interview and focus group findings to examine the role of collaboration within the context of public-private partnerships in 11 child welfare systems implementing SC. Participants included administrators of government child welfare systems and community-based organizations, as well as supervisors, coaches, and home visitors of the SC program. Sites were classified as fully-, partially-, and non-sustaining based on implementation fidelity. One-way analysis of variance was used to examine differences in stakeholder reported Effective Collaboration scores across fully-sustaining, partially-sustaining, and non-sustaining sites. Qualitative transcripts were analyzed via open and focused coding to identify the commonality, diversity, and complexity of collaborations involved in implementing and sustaining SC. Fully-sustaining sites reported significantly greater levels of effective collaboration than non-sustaining sites. Key themes described by SC stakeholders included shared vision, building on existing relationships, academic support, problem solving and resource sharing, and maintaining collaborations over time. Both quantitative and qualitative results converge in highlighting the importance of effective collaboration in EBI sustainment in child welfare service systems. PMID:26712422

  10. Design and numerical characterization of a crossover EBIS

    NASA Astrophysics Data System (ADS)

    Geyer, Sabrina; Langbein, A.; Meusel, Oliver; Kester, Oliver

    2015-01-01

    For the investigation of highly charged ions, a crossover EBIS (XEBIS) was developed at the University of Frankfurt. In contrast to conventional EBIS/T devices the compression of the electron beam is achieved by electrostatic focusing to a crossover point in the interaction region. This concept allows a compact and simple design. Simulations performed with EGUN show a perveance of 2.1×10-7 A/V3/2 for the realized gun system. In the interaction region the electron beam has a density of around 10 A/cm2 and a minimum radius of 0.15 mm. The XEBIS has a total length of 112 mm with a trap length of 26 mm. It is designed for electron beam energies of up to 6 keV/q. The storage capacity of the trap region is in the order of 1×108 charges. Charge state breeding studies with CBSIM indicate for the noble gases as maximal achievable charge state Ar16+, Kr30+ and Xe35+. Thus ion beam currents of around 2.04 nA assuming 50 Hz repetition rate can be expected. The emittance of the extracted beam is approximated to 8 mm mrad. After completion of the construction phase, the XEBIS will be installed for first performance investigations at a dedicated test bench, equipped with a fast Faraday Cup (FC), a retarding field spectrometer, a luminescence screen and optical diagnostics. Subsequently the XEBIS will serve as source for highly charged ions at different experimental setups.

  11. Development of the Oldenburg Epistemic Beliefs Questionnaire (OLEQ), a German Questionnaire Based on the Epistemic Belief Inventory (EBI)

    ERIC Educational Resources Information Center

    Paechter, Manuela; Rebmann, Karin; Schloemer, Tobias; Mokwinski, Bjoern; Hanekamp, Yvonne; Arendasy, Martin

    2013-01-01

    The present research describes the development of a German questionnaire for measurement of domain-general epistemic beliefs. Pre-studies on the psychometric properties of a German version of the Epistemic Beliefs Inventory (EBI) had emphasized the necessity to develop an instrument that is especially constructed for German-speaking samples. The…

  12. Characteristics and circumstances of injuries vary with ethnicity of different population groups living in the same country.

    PubMed

    Tiruneh, Abebe; Siman-Tov, Maya; Radomislensky, Irina; Itg; Peleg, Kobi

    2017-02-01

    To examine whether characteristics and circumstances of injuries are related to ethnicity. The study was based on the Israeli National Trauma Registry data for patients hospitalized between 2008 and 2011. Data included demographics, injury, hospital resource utilization characteristics and outcome at discharge. Univariate analysis followed by logistic regression models were undertaken to examine the relationship between injury and ethnicity. The study included 116,946 subjects; 1% were Ethiopian Born Israelis (EBI), 11% Israelis born in the Former Soviet Union (FSUBI) and 88% the remaining Israelis (RI). EBI were injured more on street or at work place and had higher rates of penetrating and severe injuries. However, FSUBI were mostly injured at home, and had higher rates of fall injuries and hip fracture. Adjusted analysis showed that EBI and FSUBI were more likely to be hospitalized because of violence-related injuries compared with RI but less likely because of road traffic injuries. Undergoing surgery and referral for rehabilitation were greater among FSUBI, while admission to intensive care unit was greater among EBI. Targeted intervention programmes need to be developed for immigrants of different countries of origin in accordance with the identified characteristics.

  13. Lessons Learned From Dissemination of Evidence-Based Interventions for HIV Prevention.

    PubMed

    Collins, Charles B; Sapiano, Tobey N

    2016-10-01

    In 1999, IOM issued a report that recommended that the Centers for Disease Control and Prevention should disseminate evidence-based HIV prevention interventions (EBIs) to be implemented by health departments, community-based organizations, drug treatment centers, and clinics. Based on these recommendations, the Diffusion of Effective Behavioral Interventions Project was initiated in 2000 and began disseminating interventions into public health practice. For 15 years, the Centers for Disease Control and Prevention has disseminated 29 EBIs to more than 11,300 agencies. Lessons were identified during the 15 years of implementation regarding successful methods of dissemination of EBIs. Lessons around selecting interventions for dissemination, developing a dissemination infrastructure including a resource website (https://effectiveinterventions.cdc.gov), and engagement with stakeholders are discussed. A continuous development approach ensured that intervention implementation materials, instructions, and technical assistance were all tailored to the needs of end users, focus populations, and agency capacities. Six follow-up studies demonstrated that adopters of EBIs were able to obtain comparable outcomes to those of the original efficacy research. The Diffusion of Effective Behavioral Interventions Project may offer guidance for other large, national, evidence-based public health dissemination projects. Published by Elsevier Inc.

  14. Nationally Certified School Psychologists' use and reported barriers to using evidence-based interventions in schools: the influence of graduate program training and education.

    PubMed

    Hicks, Taylor B; Shahidullah, Jeffrey D; Carlson, John S; Palejwala, Mohammed H

    2014-12-01

    The purpose of this study was to empirically investigate Nationally Certified School Psychologists' (NCSP) training in and use of evidence-based interventions (EBIs) for child behavior concerns as well as their reported implementation barriers. A modified Tailored Design Method (TDM; Dillman, Smyth, & Christian, 2009) using up to four mail-based participant contacts was used to obtain survey data (72% usable response rate; n = 392) from a randomly selected national sample of 548 currently practicing NCSPs. Lack of time was rated as the most serious barrier to behavioral EBI implementation, followed by a lack of necessary resources, and financial constraints. Nearly three-quarters (71%) of respondents reported a perceived inadequacy of graduate program training in behavioral EBIs, with a statistically significant difference found between respondents who attended American Psychological Association (APA)-accredited/National Association of School Psychologists (NASP)-approved programs and those who did not. These findings highlight the significant barriers school psychologists encounter when attempting to implement behavioral EBIs within applied practice, as well as the importance of graduate program training in implementation science. Implications for training, practice, and research are discussed. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  15. Effect of psychological stress on gastric motility assessed by electrical bio-impedance.

    PubMed

    Huerta-Franco, María Raquel; Vargas-Luna, Miguel; Montes-Frausto, Juana Berenice; Morales-Mata, Ismael; Ramirez-Padilla, Lorena

    2012-09-28

    To evaluate gastric motility using electrical bio-impedance (EBI) and gastric changes as a result of stress induced by psychological tests. A group of 57 healthy women, aged 40-60 years, was recruited, and a clinical history and physical examination were performed. The women were free from severe anxiety, chronic or acute stress, severe depression, mental diseases and conditions that affect gastric activity. The women were evaluated under fasting conditions, and using a four-electrode configuration, the gastric signals were obtained through a BIOPAC MP-150 system. The volunteers were evaluated using the following paradigm: basal state, recording during the Stroop Test, intermediate resting period, recording during the Raven Test, and a final resting period. We analyzed the relative areas of the frequency spectrum: A1 (1-2 cpm), A2 (2-4 cpm), A3 (4-8 cpm), and A4 (8-12 cpm), as well as the median of area A2 + A3. The data were analyzed by an autoregressive method using a Butterworth filter with MatLab and Origin. Analysis of variance (ANOVA) and Friedman ANOVA (for nonparametric variables) were performed; in addition, pairs of groups were compared using the T dependent and Wilcoxon T tests. The results of the main values of area A2 were not significantly different comparing the five steps of the experimental paradigm. Nevertheless, there was a tendency of this A2 region to decrease during the stress tests, with recuperation at the final resting step. When an extended gastric region was considered (1-4 cpm), significant differences with the psychological stress tests were present (F = 3.85, P = 0.005). The A3 region also showed significant changes when the stress psychological tests were administered (F = 7.25, P < 0.001). These differences were influenced by the changes in the adjacent gastric region of A2. The parameter that we proposed in previous studies for the evaluation of gastric motility by electrical bio-impedance (EBI) was the median of the area under the region from 2 to 8 cpm (A2 + A3). The mean values of these frequencies (median of the A2 + A3 area) with the stress test showed significant changes (F = 5.5, P < 0.001). The results of the Wilcoxon T test for the A4 area parameter, which is influenced by the breathing response, changed significantly during the Raven stress test (P < 0.05). We confirm that the gastric response to acute psychological stress can be evaluated by short-term EBI.

  16. Implementing referral to an electronic alcohol brief advice website in primary healthcare: results from the ODHIN implementation trial.

    PubMed

    Bendtsen, Preben; Müssener, Ulrika; Karlsson, Nadine; López-Pelayo, Hugo; Palacio-Vieira, Jorge; Colom, Joan; Gual, Antoni; Reynolds, Jillian; Wallace, Paul; Segura, Lidia; Anderson, Peter

    2016-06-16

    The objective of the present study was to explore whether the possibility of offering facilitated access to an alcohol electronic brief intervention (eBI) instead of delivering brief face-to-face advice increased the proportion of consulting adults who were screened and given brief advice. The study was a 12-week implementation study. Sixty primary healthcare units (PHCUs) in 5 jurisdictions (Catalonia, England, the Netherlands, Poland and Sweden) were asked to screen adults who attended the PHCU for risky drinking. A total of 120 primary healthcare centres from 5 jurisdictions in Europe. 746 individual providers (general practitioners, nurses or other professionals) participated in the study. Change in the proportion of patients screened and referred to eBI comparing a baseline 4-week preimplementation period with a 12-week implementation period. The possibility of referring patients to the eBI was not found to be associated with any increase in the proportion of patients screened. However, it was associated with an increase in the proportion of screen-positive patients receiving brief advice from 70% to 80% for the screen-positive sample as a whole (p<0.05), mainly driven by a significant increase in brief intervention rates in England from 87% to 96% (p<0.01). The study indicated that staff displayed a low level of engagement in this new technology. Staff continued to offer face-to-face advice to a larger proportion of patients (54%) than referral to eBI (38%). In addition, low engagement was seen among the referred patients; on average, 18% of the patients logged on to the website with a mean log-on rate across the different countries between 0.58% and 36.95%. Referral to eBI takes nearly as much time as brief oral advice and might require more introduction and training before staff are comfortable with referring to eBI. NCT01501552; Post-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Naringin alleviates early brain injury after experimental subarachnoid hemorrhage by reducing oxidative stress and inhibiting apoptosis.

    PubMed

    Han, Yuwei; Su, Jingyuan; Liu, Xiujuan; Zhao, Yuan; Wang, Chenchen; Li, Xiaoming

    2017-07-01

    This study aims to clarify the neuroprotective effect of naringin on early brain injury (EBI) following subarachnoid hemorrhage (SAH) and the possible mechanisms of naringin in the treatment of SAH. The endovascular puncture model was performed to induce SAH model in rats and the efficacy of 40mg/kg and 80mg/kg naringin were tested by intraperitoneally administration. SAH grade, neurological score, brain edema, blood-brain barrier permeability, the changes of oxidative stress related factors, apoptosis-related proteins, mitogen-activated protein kinase (MAPK) signaling pathway and neuronal morphology were detected to analyze the potential effect of naringin against SAH. The results demonstrated that naringin significantly ameliorated EBI, including SAH severity, neurologic deficits, brain edema and blood-brain barrier integrity by attenuating SAH-induced oxidative stress and apoptosis, and reduced the oxidant damage and apoptosis by inhibiting the activation of MAPK signaling pathway, which suggested a therapeutic potential of naringin in providing neuroprotection after SAH. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. EBI1/CCR7 is a new member of dendritic cell chemokine receptor that is up-regulated upon maturation.

    PubMed

    Yanagihara, S; Komura, E; Nagafune, J; Watarai, H; Yamaguchi, Y

    1998-09-15

    Dendritic cells (DC) that are stimulated with inflammatory mediators can maturate and migrate from nonlymphoid tissues to lymphoid organs to initiate T cell-mediated immune responses. This migratory step is closely related to the maturation of the DC. In an attempt to identify chemokine receptors that might influence migration and are selectively expressed in mature DC, we have discovered that the chemokine receptor, EBI1/CCR7, is strikingly up-regulated upon maturation in three distinct culture systems: 1) mouse bone marrow-derived DC, 2) mouse epidermal Langerhans cells, and 3) human monocyte-derived DC. The EBI1/CCR7 expressed in mature DC is functional because ELC/MIP-3beta, recently identified as a ligand of EBI1/CCR7, induces a rise in intracellular free calcium concentrations and directional migration of human monocyte-derived mature DC (HLA-DRhigh, CD1a(low), CD14-, CD25+, CD83+, and CD86high) in a dose-dependent manner, but not of immature DC (HLA-DRlow, CD1a(high), CD14-, CD25-, CD83-, and CD86-). In contrast, macrophage inflammatory protein-1alpha (MIP-1alpha), monocyte chemotactic protein-3 (MCP-3), and RANTES are active on immature DC but not on mature DC. Thus, it seems likely that MIP-1alpha, MCP-3, and RANTES can mediate the migration of immature DC located in peripheral sites, whereas ELC/MIP-3beta can direct the migration of Ag-carrying DC from peripheral inflammatory sites, where DC are stimulated to up-regulate the expression of EBI1/CCR7, to lymphoid organs. It is postulated that different chemokines and chemokine receptors are involved in DC migration in vivo, depending on the maturation state of DC.

  19. Wearable Vector Electrical Bioimpedance System to Assess Knee Joint Health

    PubMed Central

    Hersek, Sinan; Töreyin, Hakan; Teague, Caitlin N.; Millard-Stafford, Mindy L.; Jeong, Hyeon-Ki; Bavare, Miheer M.; Wolkoff, Paul; Sawka, Michael N.; Inan, Omer T.

    2017-01-01

    Objective We designed and validated a portable electrical bioimpedance (EBI) system to quantify knee joint health. Methods Five separate experiments were performed to demonstrate the: (1) ability of the EBI system to assess knee injury and recovery; (2) inter-day variability of knee EBI measurements; (3) sensitivity of the system to small changes in interstitial fluid volume; (4) reducing the error of EBI measurements using acceleration signals; (5) use of the system with dry electrodes integrated to a wearable knee wrap. Results (1) The absolute difference in resistance (R) and reactance (X) from the left to the right knee was able to distinguish injured and healthy knees (p<0.05); the absolute difference in R decreased significantly (p<0.05) in injured subjects following rehabilitation. (2) The average inter-day variability (standard deviation) of the absolute difference in knee R was 2.5Ω, and for X was, 1.2 Ω. (3) Local heating/cooling resulted in a significant decrease/increase in knee R (p<0.01). (4) The proposed subject position detection algorithm achieved 97.4% leave-one subject out cross-validated accuracy and 98.2% precision in detecting when the subject is in the correct position to take measurements. (5) Linear regression between the knee R and X measured using the wet electrodes and the designed wearable knee wrap were highly correlated (r2 = 0.8 and 0.9, respectively). Conclusion This work demonstrates the use of wearable EBI measurements in monitoring knee joint health. Significance The proposed wearable system has the potential for assessing knee joint health outside the clinic/lab and help guide rehabilitation. PMID:28026745

  20. Wearable Vector Electrical Bioimpedance System to Assess Knee Joint Health.

    PubMed

    Hersek, Sinan; Toreyin, Hakan; Teague, Caitlin N; Millard-Stafford, Mindy L; Jeong, Hyeon-Ki; Bavare, Miheer M; Wolkoff, Paul; Sawka, Michael N; Inan, Omer T

    2017-10-01

    We designed and validated a portable electrical bioimpedance (EBI) system to quantify knee joint health. Five separate experiments were performed to demonstrate the: 1) ability of the EBI system to assess knee injury and recovery; 2) interday variability of knee EBI measurements; 3) sensitivity of the system to small changes in interstitial fluid volume; 4) reducing the error of EBI measurements using acceleration signals; and 5) use of the system with dry electrodes integrated to a wearable knee wrap. 1) The absolute difference in resistance ( R) and reactance (X) from the left to the right knee was able to distinguish injured and healthy knees (p < 0.05); the absolute difference in R decreased significantly (p < 0.05) in injured subjects following rehabilitation. 2) The average interday variability (standard deviation) of the absolute difference in knee R was 2.5 Ω and for X was 1.2 Ω. 3) Local heating/cooling resulted in a significant decrease/increase in knee R (p < 0.01). 4) The proposed subject position detection algorithm achieved 97.4% leave-one subject out cross-validated accuracy and 98.2% precision in detecting when the subject is in the correct position to take measurements. 5) Linear regression between the knee R and X measured using the wet electrodes and the designed wearable knee wrap were highly correlated ( R 2 = 0.8 and 0.9, respectively). This study demonstrates the use of wearable EBI measurements in monitoring knee joint health. The proposed wearable system has the potential for assessing knee joint health outside the clinic/lab and help guide rehabilitation.

  1. Analysis Tool Web Services from the EMBL-EBI.

    PubMed

    McWilliam, Hamish; Li, Weizhong; Uludag, Mahmut; Squizzato, Silvano; Park, Young Mi; Buso, Nicola; Cowley, Andrew Peter; Lopez, Rodrigo

    2013-07-01

    Since 2004 the European Bioinformatics Institute (EMBL-EBI) has provided access to a wide range of databases and analysis tools via Web Services interfaces. This comprises services to search across the databases available from the EMBL-EBI and to explore the network of cross-references present in the data (e.g. EB-eye), services to retrieve entry data in various data formats and to access the data in specific fields (e.g. dbfetch), and analysis tool services, for example, sequence similarity search (e.g. FASTA and NCBI BLAST), multiple sequence alignment (e.g. Clustal Omega and MUSCLE), pairwise sequence alignment and protein functional analysis (e.g. InterProScan and Phobius). The REST/SOAP Web Services (http://www.ebi.ac.uk/Tools/webservices/) interfaces to these databases and tools allow their integration into other tools, applications, web sites, pipeline processes and analytical workflows. To get users started using the Web Services, sample clients are provided covering a range of programming languages and popular Web Service tool kits, and a brief guide to Web Services technologies, including a set of tutorials, is available for those wishing to learn more and develop their own clients. Users of the Web Services are informed of improvements and updates via a range of methods.

  2. Analysis Tool Web Services from the EMBL-EBI

    PubMed Central

    McWilliam, Hamish; Li, Weizhong; Uludag, Mahmut; Squizzato, Silvano; Park, Young Mi; Buso, Nicola; Cowley, Andrew Peter; Lopez, Rodrigo

    2013-01-01

    Since 2004 the European Bioinformatics Institute (EMBL-EBI) has provided access to a wide range of databases and analysis tools via Web Services interfaces. This comprises services to search across the databases available from the EMBL-EBI and to explore the network of cross-references present in the data (e.g. EB-eye), services to retrieve entry data in various data formats and to access the data in specific fields (e.g. dbfetch), and analysis tool services, for example, sequence similarity search (e.g. FASTA and NCBI BLAST), multiple sequence alignment (e.g. Clustal Omega and MUSCLE), pairwise sequence alignment and protein functional analysis (e.g. InterProScan and Phobius). The REST/SOAP Web Services (http://www.ebi.ac.uk/Tools/webservices/) interfaces to these databases and tools allow their integration into other tools, applications, web sites, pipeline processes and analytical workflows. To get users started using the Web Services, sample clients are provided covering a range of programming languages and popular Web Service tool kits, and a brief guide to Web Services technologies, including a set of tutorials, is available for those wishing to learn more and develop their own clients. Users of the Web Services are informed of improvements and updates via a range of methods. PMID:23671338

  3. Possible Role of Inflammation and Galectin-3 in Brain Injury after Subarachnoid Hemorrhage

    PubMed Central

    2018-01-01

    Aneurysmal subarachnoid hemorrhage (SAH) is known as one of the most devastating diseases in the central nervous system. In the past few decades, research on SAH has focused on cerebral vasospasm to prevent post-SAH delayed cerebral ischemia (DCI) and to improve outcomes. However, increasing evidence has suggested that early brain injury (EBI) is an important mechanism contributing to DCI, cerebral vasospasm as well as poor outcomes. Though the mechanism of EBI is very complex, inflammation is thought to play a pivotal role in EBI. Galectin-3 is a unique chimera type in the galectin family characterized by its β-galactoside-binding lectin, which mediates various pathologies, such as fibrosis, cell adhesion, and inflammation. Recently, two clinical studies revealed galectin-3 to be a possible prognostic biomarker in SAH patients. In addition, our recent report suggested that higher acute-stage plasma galectin-3 levels correlated with subsequent development of delayed cerebral infarction that was not associated with vasospasm in SAH patients. We review the possible role and molecular mechanisms of inflammation as well as galectin-3 in brain injuries, especially focusing on EBI after SAH, and discuss galectin-3 as a potential new therapeutic or research target in post-SAH brain injuries. PMID:29414883

  4. Phosphorylation of Akt by SC79 Prevents Iron Accumulation and Ameliorates Early Brain Injury in a Model of Experimental Subarachnoid Hemorrhage.

    PubMed

    Hao, Shuangying; Song, Chuanhui; Shang, Longcheng; Yu, Jiang; Qiao, Tong; Li, Kuanyu

    2016-03-10

    Previous studies have demonstrated that activation of Akt may alleviate early brain injury (EBI) following subarachnoid hemorrhage (SAH). This study is undertaken to determine whether iron metabolism is involved in the beneficial effect of Akt activation after SAH. Therefore, we used a novel molecule, SC79, to activate Akt in an experimental Sprague-Dawley rat model of SAH. Rats were randomly divided into four groups as follows: sham, SAH, SAH + vehicle, SAH + SC79. The results confirmed that SC79 effectively enhanced the defense against oxidative stress and alleviated EBI in the temporal lobe after SAH. Interestingly, we found that phosphorylation of Akt by SC79 reduced cell surface transferrin receptor-mediated iron uptake and promoted ferroportin-mediated iron transport after SAH. As a result, SC79 administration diminished the iron content in the brain tissue. Moreover, the impaired Fe-S cluster biogenesis was recovered and loss of the activities of the Fe-S cluster-containing enzymes were regained, indicating that injured mitochondrial functions are restored to healthy levels. These findings suggest that disrupted iron homeostasis could contribute to EBI and Akt activation may regulate iron metabolism to relieve iron toxicity, further protecting neurons from EBI after SAH.

  5. Project power: Adapting an evidence-based HIV/STI prevention intervention for incarcerated women.

    PubMed

    Fasula, Amy M; Fogel, Catherine I; Gelaude, Deborah; Carry, Monique; Gaiter, Juarlyn; Parker, Sharon

    2013-06-01

    Incarcerated women are a critical population for targeted HIV/STI prevention programming; however, there is a dearth of evidence-based, genderspecific behavioral interventions for this population. Systematically adapting existing evidence-based interventions (EBIs) can help fill this gap. We illustrate the adaptation of the HIV/STI prevention EBI, Project Safe, for use among incarcerated women and delivery in prisons. Project POWER, the final adapted intervention, was developed using formative research with prison staff and administration, incarcerated and previously incarcerated women, and input of community advisory boards. Intervention delivery adaptations included: shorter, more frequent intervention sessions; booster sessions prior to and just after release; facilitator experience in prisons and counseling; and new videos. Intervention content adaptations addressed issues of empowerment, substance use, gender and power inequity in relationships, interpersonal violence, mental health, reentry, and social support. This illustration of the adaption process provides information to inform additional efforts to adapt EBIs for this underserved population.

  6. EBI metagenomics in 2016 - an expanding and evolving resource for the analysis and archiving of metagenomic data

    PubMed Central

    Mitchell, Alex; Bucchini, Francois; Cochrane, Guy; Denise, Hubert; Hoopen, Petra ten; Fraser, Matthew; Pesseat, Sebastien; Potter, Simon; Scheremetjew, Maxim; Sterk, Peter; Finn, Robert D.

    2016-01-01

    EBI metagenomics (https://www.ebi.ac.uk/metagenomics/) is a freely available hub for the analysis and archiving of metagenomic and metatranscriptomic data. Over the last 2 years, the resource has undergone rapid growth, with an increase of over five-fold in the number of processed samples and consequently represents one of the largest resources of analysed shotgun metagenomes. Here, we report the status of the resource in 2016 and give an overview of new developments. In particular, we describe updates to data content, a complete overhaul of the analysis pipeline, streamlining of data presentation via the website and the development of a new web based tool to compare functional analyses of sequence runs within a study. We also highlight two of the higher profile projects that have been analysed using the resource in the last year: the oceanographic projects Ocean Sampling Day and Tara Oceans. PMID:26582919

  7. cMapper: gene-centric connectivity mapper for EBI-RDF platform.

    PubMed

    Shoaib, Muhammad; Ansari, Adnan Ahmad; Ahn, Sung-Min

    2017-01-15

    In this era of biological big data, data integration has become a common task and a challenge for biologists. The Resource Description Framework (RDF) was developed to enable interoperability of heterogeneous datasets. The EBI-RDF platform enables an efficient data integration of six independent biological databases using RDF technologies and shared ontologies. However, to take advantage of this platform, biologists need to be familiar with RDF technologies and SPARQL query language. To overcome this practical limitation of the EBI-RDF platform, we developed cMapper, a web-based tool that enables biologists to search the EBI-RDF databases in a gene-centric manner without a thorough knowledge of RDF and SPARQL. cMapper allows biologists to search data entities in the EBI-RDF platform that are connected to genes or small molecules of interest in multiple biological contexts. The input to cMapper consists of a set of genes or small molecules, and the output are data entities in six independent EBI-RDF databases connected with the given genes or small molecules in the user's query. cMapper provides output to users in the form of a graph in which nodes represent data entities and the edges represent connections between data entities and inputted set of genes or small molecules. Furthermore, users can apply filters based on database, taxonomy, organ and pathways in order to focus on a core connectivity graph of their interest. Data entities from multiple databases are differentiated based on background colors. cMapper also enables users to investigate shared connections between genes or small molecules of interest. Users can view the output graph on a web browser or download it in either GraphML or JSON formats. cMapper is available as a web application with an integrated MySQL database. The web application was developed using Java and deployed on Tomcat server. We developed the user interface using HTML5, JQuery and the Cytoscape Graph API. cMapper can be accessed at http://cmapper.ewostech.net Readers can download the development manual from the website http://cmapper.ewostech.net/docs/cMapperDocumentation.pdf. Source Code is available at https://github.com/muhammadshoaib/cmapperContact:smahn@gachon.ac.krSupplementary information: Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  8. Degradation and acute toxicity removal of the antidepressant Fluoxetine (Prozac(®)) in aqueous systems by electron beam irradiation.

    PubMed

    Silva, Vanessa Honda Ogihara; Dos Santos Batista, Ana Paula; Silva Costa Teixeira, Antonio Carlos; Borrely, Sueli Ivone

    2016-06-01

    Electron beam irradiation (EBI) has been considered an advanced technology for the treatment of water and wastewater, whereas very few previous investigations reported its use for removing pharmaceutical pollutants. In this study, the degradation of fluoxetine (FLX), an antidepressant marketed as Prozac(®), was investigated by using EBI at FLX initial concentration of 19.4 ± 0.2 mg L(-1). More than 90 % FLX degradation was achieved at 0.5 kGy, with FLX below the detection limit (0.012 mg L(-1)) at doses higher than 2.5 kGy. The elucidation of organic byproducts performed using direct injection mass spectrometry, along with the results of ion chromatography, indicated hydroxylation of FLX molecules with release of fluoride and nitrate anions. Nevertheless, about 80 % of the total organic carbon concentration remained even for 7.5 kGy or higher doses. The decreases in acute toxicity achieved 86.8 and 9.6 % for Daphnia similis and Vibrio fischeri after EBI exposure at 5 kGy, respectively. These results suggest that EBI could be an alternative to eliminate FLX and to decrease residual toxicity from wastewater generated in pharmaceutical formulation facilities, although further investigation is needed for correlating the FLX degradation mechanism with the toxicity results.

  9. Enhancing capacity among faith-based organizations to implement evidence-based cancer control programs: a community-engaged approach.

    PubMed

    Leyva, Bryan; Allen, Jennifer D; Ospino, Hosffman; Tom, Laura S; Negrón, Rosalyn; Buesa, Richard; Torres, Maria Idalí

    2017-09-01

    Evidence-based interventions (EBIs) to promote cancer control among Latinos have proliferated in recent years, though adoption and implementation of these interventions by faith-based organizations (FBOs) is limited. Capacity building may be one strategy to promote implementation. In this qualitative study, 18 community key informants were interviewed to (a) understand existing capacity for health programming among Catholic parishes, (b) characterize parishes' resource gaps and capacity-building needs implementing cancer control EBIs, and (c) elucidate strategies for delivering capacity-building assistance to parishes to facilitate implementation of EBIs. Semi-structured qualitative interviews were conducted. Key informants concurred about the capacity of Catholic parishes to deliver health programs, and described attributes of parishes that make them strong partners in health promotion initiatives, including a mission to address physical and mental health, outreach to marginalized groups, altruism among members, and existing engagement in health programming. However, resource gaps and capacity building needs were also identified. Specific recommendations participants made about how existing resources might be leveraged to address challenges include to: establish parish wellness committees; provide "hands-on" learning opportunities for parishioners to gain program planning skills; offer continuous, tailored, on-site technical assistance; facilitate relationships between parishes and community resources; and provide financial support for parishes. Leveraging parishes' existing resources and addressing their implementation needs may improve adoption of cancer control EBIs.

  10. Inhibition of mammalian target of rapamycin attenuates early brain injury through modulating microglial polarization after experimental subarachnoid hemorrhage in rats.

    PubMed

    You, Wanchun; Wang, Zhong; Li, Haiying; Shen, Haitao; Xu, Xiang; Jia, Genlai; Chen, Gang

    2016-08-15

    Here, we aimed to study the role and underlying mechanism of mTOR in early brain injury (EBI) after subarachnoid hemorrhage (SAH). Experiment 1, the time course of mTOR activation in the cortex following SAH. Experiment 2, the role of mTOR in SAH-induced EBI. Adult SD rats were divided into four groups: sham group (n=18), SAH+vehicle group (n=18), SAH+rapamycin group (n=18), SAH+AZD8055 group (n=18). Experiment 3, we incubated enriched microglia with OxyHb. Rapamycin and AZD8055 were also used to demonstrate the mTOR's role on microglial polarization in vitro. The phosphorylation levels of mTOR and its substrates were significantly increased and peaked at 24h after SAH. Rapamycin or AZD8055 markedly decreased the phosphorylation levels of mTOR and its substrates and the activation of microglia in vivo, and promoted the microglial polarization from M1 phenotype to M2 phenotype. In addition, administration of rapamycin and AZD8055 following SAH significantly ameliorated EBI, including neuronal apoptosis, neuronal necrosis, brain edema and blood-brain barrier permeability. Our findings suggested that the rapamycin and AZD8055 could attenuate the development of EBI in this SAH model, possibly through inhibiting the activation of microglia by mTOR pathway. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Radiofrequency quadrupole-based beam cooler and buncher for the CANREB project at TRIUMF

    NASA Astrophysics Data System (ADS)

    Barquest, Brad; Pearson, Matt; Ames, Friedhelm; Dilling, Jens; Gwinner, Gerald; Kanungo, Rituparna; Kruecken, Reiner

    2016-09-01

    A new radiofrequency quadrupole-based ion beam cooler and buncher (BCB) and pulsed drift tube (PDT) have been designed as part of the CANREB project at TRIUMF. The BCB is designed to accept continuous 60 keV rare isotope beams from the ARIEL or ISAC production targets and efficiently deliver low-emittance, bunched beams of up to 107 ions per bunch to an electron beam ion source (EBIS) to charge-breed the bunch for post-acceleration. The PDT will adjust the energy of the bunched beam from 60 keV to 10-14 keV for injection into the EBIS. The injection energy is determined by the acceptance of the post-accelerating RFQ. The design of the BCB is nearing completion, and fabrication and assembly effort will proceed shortly. In addition, a PDT prototype is under development to test that the design concept satisfies the voltage and switching time requirements. Design features of the BCB and PDT will be discussed, and an update on BCB assembly and PDT testing progress will be presented. CANREB is funded by CFI, NSRIT, Manitoba Research and Innovation Fund, AAPS, Saint Mary's U, U of Manitoba and TRIUMF. TRIUMF receives federal funding via a contribution agreement with the National Research Council of Canada.

  12. Expanding Diversity in Molecular Structures and Functions of the IL-6/IL-12 Heterodimeric Cytokine Family

    PubMed Central

    Hasegawa, Hideaki; Mizoguchi, Izuru; Chiba, Yukino; Ohashi, Mio; Xu, Mingli; Yoshimoto, Takayuki

    2016-01-01

    The interleukin (IL)-6/IL-12 family cytokines have pleiotropic functions and play critical roles in multiple immune responses. This cytokine family has very unique characteristics in that they comprise two distinct subunits forming a heterodimer and each cytokine and receptor subunit shares with each other. The members of this cytokine family are increasing; currently, there are more than six cytokines, including the tentatively named cytokines IL-Y (p28/p40), IL-12 (p35/p40), IL-23 (p19/p40), IL-27 [p28/Epstein–Barr virus-induced protein 3 (EBI3)], IL-35 (p35/EBI3), and IL-39 (p19/EBI3). This family of cytokines covers a very broad range of immune responses, including pro-inflammatory responses, such as helper T (Th)1, Th2, and Th17, to anti-inflammatory responses, such as regulatory T (Treg) cells and IL-10-producing Treg cells. IL-12 is the first member of this family, and IL-12, IL-23, and IL-27 are mainly produced by activated antigen-presenting cells, such as dendritic cells and macrophages. IL-12 plays a critical role in the promotion of Th1 immune responses by inducing interferon-γ production to combat pathogens and malignant tumors. IL-23 induces IL-17 production and is necessary to maintain pathogenic Th17 cells that cause inflammatory and autoimmune diseases. IL-27 was initially reported to play a critical role in promotion of Th1 differentiation; however, subsequent studies revealed that IL-27 has broader stimulatory and inhibitory roles by inducing IL-10-producing Treg cells. IL-35 is produced by forkhead box P3+ Treg cells and activated B cells and has immunosuppressive functions to maintain immune tolerance. The most recently identified cytokine, IL-39, is produced by activated B cells and has pro-inflammatory functions. The cytokine tentatively named IL-Y seems to have anti-inflammatory functions by inhibiting Th1 and Th17 differentiation. In addition, individual cytokine subunits were also shown to have self-standing activities. Thus, promiscuity within the IL-6/IL-12 family cytokines complicates structural and functional clarification and assignment of individual cytokines. A better understanding of the recent advances and expanding diversity in molecular structures and functions of the IL-6/IL-12 family cytokines could allow the creation of novel therapeutic strategies by using them as tools and targeted molecules. PMID:27867385

  13. Permanent magnet electron beam ion source/trap systems with bakeable magnets for improved operation conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmidt, M., E-mail: mike.schmidt@dreebit.com; Zschornack, G.; Kentsch, U.

    The magnetic system of a Dresden electron beam ion source (EBIS) generating the necessary magnetic field with a new type of permanent magnet made of high energy density NdFeB-type material operable at temperatures above 100 °C has been investigated and tested. The employment of such kind of magnets provides simplified operation without the time-consuming installation and de-installation procedures of the magnets for the necessary baking of the ion source after commissioning and maintenance work. Furthermore, with the use of a new magnetization technique the geometrical filling factor of the magnetic Dresden EBIS design could be increased to a filling factor ofmore » 100% leading to an axial magnetic field strength of approximately 0.5 T exceeding the old design by 20%. Simulations using the finite element method software Field Precision and their results compared with measurements are presented as well. It could be shown that several baking cycles at temperatures higher than 100 °C did not change the magnetic properties of the setup.« less

  14. Permanent magnet electron beam ion source/trap systems with bakeable magnets for improved operation conditions.

    PubMed

    Schmidt, M; Zschornack, G; Kentsch, U; Ritter, E

    2014-02-01

    The magnetic system of a Dresden electron beam ion source (EBIS) generating the necessary magnetic field with a new type of permanent magnet made of high energy density NdFeB-type material operable at temperatures above 100 °C has been investigated and tested. The employment of such kind of magnets provides simplified operation without the time-consuming installation and de-installation procedures of the magnets for the necessary baking of the ion source after commissioning and maintenance work. Furthermore, with the use of a new magnetization technique the geometrical filling factor of the magnetic Dresden EBIS design could be increased to a filling factor of 100% leading to an axial magnetic field strength of approximately 0.5 T exceeding the old design by 20%. Simulations using the finite element method software Field Precision and their results compared with measurements are presented as well. It could be shown that several baking cycles at temperatures higher than 100 °C did not change the magnetic properties of the setup.

  15. A zone-specific fish-based biotic index as a management tool for the Zeeschelde estuary (Belgium).

    PubMed

    Breine, Jan; Quataert, Paul; Stevens, Maarten; Ollevier, Frans; Volckaert, Filip A M; Van den Bergh, Ericia; Maes, Joachim

    2010-07-01

    Fish-based indices monitor changes in surface waters and are a valuable aid in communication by summarising complex information about the environment (Harrison and Whitfield, 2004). A zone-specific fish-based multimetric estuarine index of biotic integrity (Z-EBI) was developed based on a 13 year time series of fish surveys from the Zeeschelde estuary (Belgium). Sites were pre-classified using indicators of anthropogenic impact. Metrics showing a monotone response with pressure classes were selected for further analysis. Thresholds for the good ecological potential (GEP) were defined from references. A modified trisection was applied for the other thresholds. The Z-EBI is defined by the average of the metric scores calculated over a one year period and translated into an ecological quality ratio (EQR). The indices integrate structural and functional qualities of the estuarine fish communities. The Z-EBI performances were successfully validated for habitat degradation in the various habitat zones. Copyright 2010 Elsevier Ltd. All rights reserved.

  16. Capability for change at community health centers serving Asian Pacific Islanders: an exploratory study of a cancer screening evidence-based intervention.

    PubMed

    Sohng, Hee Yon; Kuniyuki, Alan; Edelson, Jane; Weir, Rosy Chang; Song, Hui; Tu, Shin-Ping

    2013-01-01

    Understanding and enhancing change capabilities, including Practice Adaptive Reserve (PAR), of Community Health Centers (CHCs) may mitigate cancer-related health disparities. Using stratified random sampling, we recruited 232 staff from seven CHCs serving Asian Pacific Islander communities to complete a self-administered survey. We performed multilevel regression analyses to examine PAR composite scores by CHC, position type, and number of years worked at their clinic. The mean PAR score was 0.7 (s.d. 0.14). Higher scores were associated with a greater perceived likelihood that clinic staff would participate in an evidence-based intervention (EBI). Constructs such as communication, clinic flow, sensemaking, change valence, and resource availability were positively associated with EBI implementation or trended toward significance. PAR scores are positively associated with perceived likelihood of clinic staff participation in cancer screening EBI. Future research is needed to determine PAR levels most conducive to implementing change and to developing interventions that enhance Adaptive Reserve.

  17. Study of the Dynamics of Transcephalic Cerebral Impedance Data during Cardio-Vascular Surgery

    NASA Astrophysics Data System (ADS)

    Atefi, S. R.; Seoane, F.; Lindecrantz, K.

    2013-04-01

    Postoperative neurological deficits are one of the risks associated with cardio vascular surgery, necessitating development of new techniques for cerebral monitoring. In this study an experimental observation regarding the dynamics of transcephalic Electrical Bioimpedance (EBI) in patients undergoing cardiac surgery with and without extracorporeal circulation (ECC) was conducted to investigate the potential use of electrical Bioimpedance for cerebral monitoring in cardio vascular surgery. Tetrapolar transcephalic EBI measurements at single frequency of 50 kHz were recorded prior to and during cardio vascular surgery. The obtained results show that the transcephalic impedance decreases in both groups of patients as operation starts, however slight differences in these two groups were also observed with the cerebral impedance reduction in patients having no ECC being less common and not as pronounced as in the ECC group. Changes in the cerebral impedance were in agreement with changes of haematocrit and temperature. The origin of EBI changes is still unexplained however these results encourage us to continue investigating the application of electrical bioimpedance cerebral monitoring clinically.

  18. Health Ministry and Activities in African American Faith-Based Organizations: A Qualitative Examination of Facilitators, Barriers, and Use of Technology.

    PubMed

    Holt, Cheryl L; Graham-Phillips, Anita L; Daniel Mullins, C; Slade, Jimmie L; Savoy, Alma; Carter, Roxanne

    2017-01-01

    African American faith-based organizations (FBOs) play an important role in addressing health disparities. Increasingly, churches offer health fairs, screenings, or education through health ministries. However, little is known about linking these organizations with evidence-based interventions (EBIs) developed by research. This study explored 1) factors that facilitate or impede health ministry activities, including the adoption of EBIs, and 2) opportunities to use technology to support/enhance the capacity of FBOs to sustain health-related activities. We conducted 18 key informant interviews with African American pastors and FBO leaders and six focus groups with members. A popular health ministry strategy was distribution of print materials. There was limited awareness of EBIs and how to access them. Challenges included maintaining qualified volunteers, financial resources, and technical assistance needs. Participants used technology and social media but older adults did so less often. Findings have implications for dissemination/implementation research in FBOs, in relation to the translational continuum.

  19. Apigenin protects blood-brain barrier and ameliorates early brain injury by inhibiting TLR4-mediated inflammatory pathway in subarachnoid hemorrhage rats.

    PubMed

    Zhang, Tingting; Su, Jingyuan; Guo, Bingyu; Wang, Kaiwen; Li, Xiaoming; Liang, Guobiao

    2015-09-01

    Early brain injury (EBI) following subarachnoid hemorrhage (SAH) is associated with high morbidity and mortality. Inflammation has been considered as the major contributor to brain damage after SAH. SAH induces a systemic increase in pro-inflammatory cytokines and chemokines. Disruption of blood-brain barrier (BBB) facilitates the influx of inflammatory cells. It has been reported that the activation of toll-like receptor 4 (TLR4)/NF-κB signaling pathway plays a vital role in the central nervous system diseases. Apigenin, a common plant flavonoid, possesses anti-inflammation effect. In this study, we focused on the effects of apigenin on EBI following SAH and its anti-inflammation mechanism. Our results showed that apigenin (20mg/kg) administration significantly attenuated EBI (including brain edema, BBB disruption, neurological deficient, severity of SAH, and cell apoptosis) after SAH in rats by suppressing the expression of TLR4, NF-κB and their downstream pro-inflammatory cytokines in the cortex and by up-regulating the expression of tight junction proteins of BBB. Double immunofluorescence staining demonstrated that TLR4 was activated following SAH in neurons, microglia cells, and endothelial cells but not in astrocytes. Apigenin could suppress the activation of TLR4 induced by SAH and inhibit apoptosis of cells in the cortex. These results suggested that apigenin could attenuate EBI after SAH in rats by suppressing TLR4-mediated inflammation and protecting against BBB disruption. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. I. Direct observation of zirconocene-catalyzed alkene polymerization via NMR and the role of an aluminum alkyl during polymerization. II. Design and evaluation of an online nanoscience course for teachers

    NASA Astrophysics Data System (ADS)

    Tomasik, Janice Hall

    The plastics industry has been revolutionalized by development of group 4 metallocene polymerization catalysts. These catalysts have higher activities and stereoselectivities than traditional heterogeneous Ziegler-Natta polymerization catalysts, and produce polymers with narrower molecular weight distributions and with better control of the polymer stereochemistry. The reaction kinetics of catalytic alkene polymerizations are complicated and difficult to resolve macroscopically. To overcome these difficulties, research has used NMR spectroscopy to directly observe catalytic reaction intermediates; many advances in our understanding of the complex mechanisms behind these polymerization reactions have resulted. In this work, the direct observation of alkene insertion into zirconocene-polymeryls via NMR spectroscopy is presented. Alkenes studied are 3-methylpentene, styrene, and 1,4-pentadiene. Kinetic measurements are reported for the polymerization of 3-methylpentene by rac-(EBI)Zr(Me)(MeB(C6F 5)3) (EBI = C2H4(1-indenyl)2) and rac-(EBI)Zr(polyhexenyl)(MeB(C6F5) 3). Also presented are NMR spectroscopic characterizations of rac-(EBI)Zr(styrenyl)(MeB(C6F5)3) and rac-(EBI)Zr(1,4-pentadienyl)(MeB(C6F 5)3). In addition, NMR spectroscopy is used to directly monitor the behavior of an aluminum alkyl during the polymerization of 1-hexene by rac -(EBI)2Zr(Me)(MeB(C6F5)3). The rates of polymerization are not inhibited by Al(iBu) 2(BHT), Al(Me)(BHT)2, or Al(iBu)3 (BHT = 2,6-di- tert-butyl-4-methylphenyl). Detailed measurement of polymerization rate and catalyst speciation demonstrate that BHT modified aluminum alkyls protect active sites from decomposition in the presence of protic impurities such as methanol. Also presented in this work is the design and evaluation of an online course for teachers about nanoscience. Nanotechnology is an important emerging field that is estimated to need about 2 million workers worldwide by 2015. Therefore the educational system is being encouraged to incorporate major nanoscience concepts into curricula. In order to facilitate the integration of nanoscience, an online professional development course for teachers has been developed and offered at the University of Wisconsin-Madison. Evaluation results from the first three versions of the course indicate the online learning environment was very close to ideal. Comparisons of pre-instruction to post-instruction quiz responses indicate significant learning gains by participants. Importantly, survey results show the online course helped teachers to successfully incorporate nanoscience into their curricula.

  1. Using EMBL-EBI services via Web interface and programmatically via Web Services

    PubMed Central

    Lopez, Rodrigo; Cowley, Andrew; Li, Weizhong; McWilliam, Hamish

    2015-01-01

    The European Bioinformatics Institute (EMBL-EBI) provides access to a wide range of databases and analysis tools that are of key importance in bioinformatics. As well as providing Web interfaces to these resources, Web Services are available using SOAP and REST protocols that enable programmatic access to our resources and allow their integration into other applications and analytical workflows. This unit describes the various options available to a typical researcher or bioinformatician who wishes to use our resources via Web interface or programmatically via a range of programming languages. PMID:25501941

  2. Charge breeding of radioactive isotopes at the CARIBU facility with an electron beam ion source

    NASA Astrophysics Data System (ADS)

    Vondrasek, R. C.; Dickerson, C. A.; Hendricks, M.; Ostroumov, P.; Pardo, R.; Savard, G.; Scott, R.; Zinkann, G.

    2018-05-01

    An Electron Beam Ion Source Charge Breeder (EBIS-CB) has been developed at Argonne National Laboratory as part of the californium rare ion breeder upgrade. For the past year, the EBIS-CB has been undergoing commissioning as part of the ATLAS accelerator complex. It has delivered both stable and radioactive beams with A/Q < 6, breeding times <30 ms, low background contamination, and charge breeding efficiencies >18% into a single charge state. The operation of this device, challenges during the commissioning phase, and future improvements will be discussed.

  3. Facilitators and barriers to effective scale-up of an evidence-based multilevel HIV prevention intervention.

    PubMed

    Kegeles, Susan M; Rebchook, Gregory; Tebbetts, Scott; Arnold, Emily

    2015-04-17

    Since the scale-up of HIV/AIDS prevention evidence-based interventions (EBIs) has not been simple, it is important to examine processes that occur in the translation of the EBIs into practice that affect successful implementation. The goal of this paper is to examine facilitators and barriers to effective implementation that arose among 72 community-based organizations as they moved into practice a multilevel HIV prevention intervention EBI, the Mpowerment Project, for young gay and bisexual men. CBOs that were implementing the Mpowerment Project participated in this study and were assessed at baseline, and 6-months, 1 year, and 2 years post-baseline. Semi-structured telephone interviews were conducted separately with individuals at each CBO. Study data came from 647 semi-structured interviews and extensive notes and commentaries from technical assistance providers. Framework Analysis guided the analytic process. Barriers and facilitators to implementation was the overarching thematic framework used across all the cases in our analysis. Thirteen themes emerged regarding factors that influence the successful implementation of the MP. These were organized into three overarching themes: HIV Prevention System Factors, Community Factors, and Intervention Factors. The entire HIV Prevention System, including coordinators, supervisors, executive directors, funders, and national HIV prevention policies, all influenced implementation success. Other Prevention System Factors that affected the effective translation of the EBI into practice include Knowledge About Intervention, Belief in the Efficacy of the Intervention, Desire to Change Existing Prevention Approach, Planning for Intervention Before Implementation, Accountability, Appropriateness of Individuals for Coordinator Positions, Evaluation of Intervention, and Organizational Stability. Community Factors included Geography and Sociopolitical Climate. Intervention Factors included Intervention Characteristics and Adaptation Issues. The entire ecological system in which an EBI occurs affects implementation. It is imperative to focus capacity-building efforts on getting individuals at different levels of the HIV Prevention System into alignment regarding understanding and believing in the program's goals and methods. For a Prevention Support System to be maximally useful, it must address facilitators or barriers to implementation, address the right people, and use modalities to convey information that are acceptable for users of the system.

  4. Surface and material analytics based on Dresden-EBIS platform technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmidt, M., E-mail: mike.schmidt@dreebit.com; König, J., E-mail: mike.schmidt@dreebit.com; Bischoff, L.

    2015-01-09

    Nowadays widely used mass spectrometry systems utilize energetic ions hitting a sample and sputter material from the surface of a specimen. The generated secondary ions are separated and detected with high mass resolution to determine the target materials constitution. Based on this principle, we present an alternative approach implementing a compact Electron Beam Ion Source (EBIS) in combination with a Liquid Metal Ion Source (LMIS). An LMIS can deliver heavy elements which generate high sputter yields on a target surface. More than 90% of this sputtered material consists of mono- and polyatomic neutrals. These particles are able to penetrate themore » magnetic field of an EBIS and they will be ionized within the electron beam. A broad spectrum of singly up to highly charged ions can be extracted depending on the operation conditions. Polyatomic ions will decay during the charge-up process. A standard bending magnet or a Wien filter is used to separate the different ion species due to their mass-to-charge ratio. Using different charge states of ions as it is common with EBIS it is also possible to resolve interfering charge-to-mass ratios of only singly charged ions. Different setups for the realization of feeding the electron beam with sputtered atoms of solids will be presented and discussed. As an example the analysis of a copper surface is used to show high-resolution spectra with low background noise. Individual copper isotopes and clusters with different isotope compositions can be resolved at equal atomic numbers. These results are a first step for the development of a new compact low-cost and high-resolution mass spectrometry system. In a more general context, the described technique demonstrates an efficient method for feeding an EBIS with atoms of nearly all solid elements from various solid target materials. The new straightforward design of the presented setup should be of high interest for a broad range of applications in materials research as well as for applications connected to analyzing the biosphere, hydrosphere, lithosphere, cosmosphere and technosphere.« less

  5. The RNASeq-er API-a gateway to systematically updated analysis of public RNA-seq data.

    PubMed

    Petryszak, Robert; Fonseca, Nuno A; Füllgrabe, Anja; Huerta, Laura; Keays, Maria; Tang, Y Amy; Brazma, Alvis

    2017-07-15

    The exponential growth of publicly available RNA-sequencing (RNA-Seq) data poses an increasing challenge to researchers wishing to discover, analyse and store such data, particularly those based in institutions with limited computational resources. EMBL-EBI is in an ideal position to address these challenges and to allow the scientific community easy access to not just raw, but also processed RNA-Seq data. We present a Web service to access the results of a systematically and continually updated standardized alignment as well as gene and exon expression quantification of all public bulk (and in the near future also single-cell) RNA-Seq runs in 264 species in European Nucleotide Archive, using Representational State Transfer. The RNASeq-er API (Application Programming Interface) enables ontology-powered search for and retrieval of CRAM, bigwig and bedGraph files, gene and exon expression quantification matrices (Fragments Per Kilobase Of Exon Per Million Fragments Mapped, Transcripts Per Million, raw counts) as well as sample attributes annotated with ontology terms. To date over 270 00 RNA-Seq runs in nearly 10 000 studies (1PB of raw FASTQ data) in 264 species in ENA have been processed and made available via the API. The RNASeq-er API can be accessed at http://www.ebi.ac.uk/fg/rnaseq/api . The commands used to analyse the data are available in supplementary materials and at https://github.com/nunofonseca/irap/wiki/iRAP-single-library . rnaseq@ebi.ac.uk ; rpetry@ebi.ac.uk. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.

  6. The annotation-enriched non-redundant patent sequence databases.

    PubMed

    Li, Weizhong; Kondratowicz, Bartosz; McWilliam, Hamish; Nauche, Stephane; Lopez, Rodrigo

    2013-01-01

    The EMBL-European Bioinformatics Institute (EMBL-EBI) offers public access to patent sequence data, providing a valuable service to the intellectual property and scientific communities. The non-redundant (NR) patent sequence databases comprise two-level nucleotide and protein sequence clusters (NRNL1, NRNL2, NRPL1 and NRPL2) based on sequence identity (level-1) and patent family (level-2). Annotation from the source entries in these databases is merged and enhanced with additional information from the patent literature and biological context. Corrections in patent publication numbers, kind-codes and patent equivalents significantly improve the data quality. Data are available through various user interfaces including web browser, downloads via FTP, SRS, Dbfetch and EBI-Search. Sequence similarity/homology searches against the databases are available using BLAST, FASTA and PSI-Search. In this article, we describe the data collection and annotation and also outline major changes and improvements introduced since 2009. Apart from data growth, these changes include additional annotation for singleton clusters, the identifier versioning for tracking entry change and the entry mappings between the two-level databases. Database URL: http://www.ebi.ac.uk/patentdata/nr/

  7. The Annotation-enriched non-redundant patent sequence databases

    PubMed Central

    Li, Weizhong; Kondratowicz, Bartosz; McWilliam, Hamish; Nauche, Stephane; Lopez, Rodrigo

    2013-01-01

    The EMBL-European Bioinformatics Institute (EMBL-EBI) offers public access to patent sequence data, providing a valuable service to the intellectual property and scientific communities. The non-redundant (NR) patent sequence databases comprise two-level nucleotide and protein sequence clusters (NRNL1, NRNL2, NRPL1 and NRPL2) based on sequence identity (level-1) and patent family (level-2). Annotation from the source entries in these databases is merged and enhanced with additional information from the patent literature and biological context. Corrections in patent publication numbers, kind-codes and patent equivalents significantly improve the data quality. Data are available through various user interfaces including web browser, downloads via FTP, SRS, Dbfetch and EBI-Search. Sequence similarity/homology searches against the databases are available using BLAST, FASTA and PSI-Search. In this article, we describe the data collection and annotation and also outline major changes and improvements introduced since 2009. Apart from data growth, these changes include additional annotation for singleton clusters, the identifier versioning for tracking entry change and the entry mappings between the two-level databases. Database URL: http://www.ebi.ac.uk/patentdata/nr/ PMID:23396323

  8. Charge breeding simulations for radioactive ion beam production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Variale, V.; Raino, A. C.; Clauser, T.

    2012-02-15

    The charge breeding technique is used for radioactive ion beam (RIB) production in order of optimizing the re-acceleration of the radioactive element ions produced by a primary beam in a thick target. Charge breeding is achieved by means of a device capable of increasing the ion charge state from 1+ to a desired value n+. In order to get high intensity RIB, experiments with charge breeding of very high efficiency could be required. To reach this goal, the charge breeding simulation could help to optimize the high charge state production efficiency by finding more proper parameters for the radioactive 1+more » ions. In this paper a device based on an electron beam ion source (EBIS) is considered. In order to study that problem, a code already developed for studying the ion selective containment in an EBIS with RF quadrupoles, BRICTEST, has been modified to simulate the ion charge state breeding rate for different 1+ ion injection conditions. Particularly, the charge breeding simulations for an EBIS with a hollow electron beam have been studied.« less

  9. Electron beam ion source and electron beam ion trap (invited).

    PubMed

    Becker, Reinard; Kester, Oliver

    2010-02-01

    The electron beam ion source (EBIS) and its trap variant [electron beam ion trap (EBIT)] celebrated their 40th and 20th anniversary, respectively, at the EBIS/T Symposium 2007 in Heidelberg. These technologically challenging sources of highly charged ions have seen a broad development in many countries over the last decades. In contrast to most other ion sources the recipe of improvement was not "sorcery" but a clear understanding of the physical laws and obeying the technological constraints. This review will report important achievements of the past as well as promising developments in the future.

  10. Using EMBL-EBI Services via Web Interface and Programmatically via Web Services.

    PubMed

    Lopez, Rodrigo; Cowley, Andrew; Li, Weizhong; McWilliam, Hamish

    2014-12-12

    The European Bioinformatics Institute (EMBL-EBI) provides access to a wide range of databases and analysis tools that are of key importance in bioinformatics. As well as providing Web interfaces to these resources, Web Services are available using SOAP and REST protocols that enable programmatic access to our resources and allow their integration into other applications and analytical workflows. This unit describes the various options available to a typical researcher or bioinformatician who wishes to use our resources via Web interface or programmatically via a range of programming languages. Copyright © 2014 John Wiley & Sons, Inc.

  11. Fisetin alleviates early brain injury following experimental subarachnoid hemorrhage in rats possibly by suppressing TLR 4/NF-κB signaling pathway.

    PubMed

    Zhou, Chen-hui; Wang, Chun-xi; Xie, Guang-bin; Wu, Ling-yun; Wei, Yong-xiang; Wang, Qiang; Zhang, Hua-sheng; Hang, Chun-hua; Zhou, Meng-liang; Shi, Ji-xin

    2015-12-10

    Early brain injury (EBI) determines the unfavorable outcomes after subarachnoid hemorrhage (SAH). Fisetin, a natural flavonoid, has anti-inflammatory and neuroprotection properties in several brain injury models, but the role of fisetin on EBI following SAH remains unknown. Our study aimed to explore the effects of fisetin on EBI after SAH in rats. Adult male Sprague-Dawley rats were randomly divided into the sham and SAH groups, fisetin (25mg/kg or 50mg/kg) or equal volume of vehicle was given at 30min after SAH. Neurological scores and brain edema were assayed. The protein expression of toll-like receptor 4 (TLR 4), p65, ZO-1 and bcl-2 was examined by Western blot. TLR 4 and p65 were also assessed by immunohistochemistry (IHC). Enzyme-linked immunosorbent assay (ELISA) was performed to detect the production of pro-inflammatory cytokines. Terminal deoxynucleotidyl transferase-mediated uridine 5'-triphosphate-biotin nick end-labeling (TUNEL) was perform to assess neural cell apoptosis. High-dose (50mg/kg) fisetin significantly improved neurological function and reduced brain edema at both 24h and 72h after SAH. Remarkable reductions of TLR 4 expression and nuclear factor κB (NF-κB) translocation to nucleus were detected after fisetin treatment. In addition, fisetin significantly reduced the productions of pro-inflammatory cytokines, decreased neural cell apoptosis and increased the protein expression of ZO-1 and bcl-2. Our data provides the evidence for the first time that fisetin plays a protective role in EBI following SAH possibly by suppressing TLR 4/NF-κB mediated inflammatory pathway. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Toward Non-Invasive and Automatic Intravenous Infiltration Detection: Evaluation of Bioimpedance and Skin Strain in a Pig Model.

    PubMed

    Bicen, A Ozan; West, Leanne L; Cesar, Liliana; Inan, Omer T

    2018-01-01

    Intravenous (IV) therapy is prevalent in hospital settings, where fluids are typically delivered with an IV into a peripheral vein of the patient. IV infiltration is the inadvertent delivery of fluids into the extravascular space rather than into the vein (and requires urgent treatment to avoid scarring and severe tissue damage), for which medical staff currently needs to check patients periodically. In this paper, the performance of two non-invasive sensing modalities, electrical bioimpedance (EBI), and skin strain sensing, for the automatic detection of IV infiltration was investigated in an animal model. Infiltrations were physically simulated on the hind limb of anesthetized pigs, where the sensors for EBI and skin strain sensing were co-located. The obtained data were used to examine the ability to distinguish between infusion into the vein and an infiltration event using bioresistance and bioreactance (derived from EBI), as well as skin strain. Skin strain and bioresistance sensing could achieve detection rates greater than 0.9 for infiltration fluid volumes of 2 and 10 mL, respectively, for a given false positive, i.e., false alarm rate of 0.05. Furthermore, the fusion of multiple sensing modalities could achieve a detection rate of 0.97 with a false alarm rate of 0.096 for 5mL fluid volume of infiltration. EBI and skin strain sensing can enable non-invasive and real-time IV infiltration detection systems. Fusion of multiple sensing modalities can help to detect expanded range of leaking fluid volumes. The provided performance results and comparisons in this paper are an important step towards clinical translation of sensing technologies for detecting IV infiltration.

  13. Toward Non-Invasive and Automatic Intravenous Infiltration Detection: Evaluation of Bioimpedance and Skin Strain in a Pig Model

    PubMed Central

    Bicen, A. Ozan; West, Leanne L.; Cesar, Liliana

    2018-01-01

    Intravenous (IV) therapy is prevalent in hospital settings, where fluids are typically delivered with an IV into a peripheral vein of the patient. IV infiltration is the inadvertent delivery of fluids into the extravascular space rather than into the vein (and requires urgent treatment to avoid scarring and severe tissue damage), for which medical staff currently needs to check patients periodically. In this paper, the performance of two non-invasive sensing modalities, electrical bioimpedance (EBI), and skin strain sensing, for the automatic detection of IV infiltration was investigated in an animal model. Infiltrations were physically simulated on the hind limb of anesthetized pigs, where the sensors for EBI and skin strain sensing were co-located. The obtained data were used to examine the ability to distinguish between infusion into the vein and an infiltration event using bioresistance and bioreactance (derived from EBI), as well as skin strain. Skin strain and bioresistance sensing could achieve detection rates greater than 0.9 for infiltration fluid volumes of 2 and 10 mL, respectively, for a given false positive, i.e., false alarm rate of 0.05. Furthermore, the fusion of multiple sensing modalities could achieve a detection rate of 0.97 with a false alarm rate of 0.096 for 5mL fluid volume of infiltration. EBI and skin strain sensing can enable non-invasive and real-time IV infiltration detection systems. Fusion of multiple sensing modalities can help to detect expanded range of leaking fluid volumes. The provided performance results and comparisons in this paper are an important step towards clinical translation of sensing technologies for detecting IV infiltration. PMID:29692956

  14. Culturable bacterial endophytes isolated from Mangrove tree (Rhizophora apiculata Blume) enhance seedling growth in Rice.

    PubMed

    Deivanai, Subramanian; Bindusara, Amitraghata Santhanam; Prabhakaran, Guruswamy; Bhore, Subhash Janardhan

    2014-07-01

    Endophytic bacteria do have several potential applications in medicine and in other various sectors of biotechnology including agriculture. Bacterial endophytes need to be explored for their potential applications in agricultural biotechnology. One of the potential applications of bacterial endophytes in agricultural is to enhance the growth of the agricultural crops. Hence, this study was undertaken to explore the plant growth promoting potential application of bacterial endophytes. The objective of this study was to examine the effect of endophytic bacteria from mangrove tree (Rhizophora apiculata Blume) for their efficacy in promoting seedling growth in rice. Eight endophytic bacterial isolates (EBIs) isolated from twig and petiole tissues of the mangrove were identified based on their 16S ribosomal ribonucleic acid (rRNA) gene sequence homology. Separately, surface sterilized paddy seeds were treated with cell-free broth and cell suspension of the EBIs. Rice seedlings were analyzed by various bioassays and data was recorded. The gene sequences of the isolates were closely related to two genera namely, Bacillus and Pantoea. Inoculation of EBIs from R. apiculata with rice seeds resulted in accelerated root and shoot growth with significant increase in chlorophyll content. Among the isolates, Pantoea ananatis (1MSE1) and Bacillus amyloliquefaciens (3MPE1) had shown predominance of activity. Endophytic invasion was recognized by the non-host by rapid accumulation of reactive oxygen species (ROS) and was counteracted by the production of hydrogen peroxide (H2O2) and lipid peroxide. The results demonstrated that EBIs from mangrove tree can increase the fitness of the rice seedlings under controlled conditions. These research findings could be useful to enhance the seedling growth and could serve as foundation in further research on enhancing the growth of the rice crop using endophytic bacteria.

  15. Synthesizing Marketing, Community Engagement, and Systems Science Approaches for Advancing Translational Research

    PubMed Central

    Kneipp, Shawn M.; Leeman, Jennifer; McCall, Pamela; Hassmiller-Lich, Kristen; Bobashev, Georgiy; Schwartz, Todd A.; Gilmore, Robert; Riggan, Scott

    2016-01-01

    The adoption and implementation of evidence-based interventions (EBIs) are end goals of translational research, however, potential end-users’ perceptions of an EBI’s value have contributed to low rates of adoption. In this article, we describe our application of emerging dissemination and implementation science theoretical perspectives, community engagement, and systems science principles to develop a novel EBI dissemination approach. Using consumer-driven, graphics-rich simulation, the approach demonstrates predicted implementation effects on health and employment outcomes for socioeconomically disadvantaged women at the local level, and is designed to increase adoption interest of county program managers accountable for improving these outcomes in their communities. PMID:26244479

  16. Rapid establishment of the European Bank for induced Pluripotent Stem Cells (EBiSC) - the Hot Start experience.

    PubMed

    De Sousa, Paul A; Steeg, Rachel; Wachter, Elisabeth; Bruce, Kevin; King, Jason; Hoeve, Marieke; Khadun, Shalinee; McConnachie, George; Holder, Julie; Kurtz, Andreas; Seltmann, Stefanie; Dewender, Johannes; Reimann, Sascha; Stacey, Glyn; O'Shea, Orla; Chapman, Charlotte; Healy, Lyn; Zimmermann, Heiko; Bolton, Bryan; Rawat, Trisha; Atkin, Isobel; Veiga, Anna; Kuebler, Bernd; Serano, Blanca Miranda; Saric, Tomo; Hescheler, Jürgen; Brüstle, Oliver; Peitz, Michael; Thiele, Cornelia; Geijsen, Niels; Holst, Bjørn; Clausen, Christian; Lako, Majlinda; Armstrong, Lyle; Gupta, Shailesh K; Kvist, Alexander J; Hicks, Ryan; Jonebring, Anna; Brolén, Gabriella; Ebneth, Andreas; Cabrera-Socorro, Alfredo; Foerch, Patrik; Geraerts, Martine; Stummann, Tina C; Harmon, Shawn; George, Carol; Streeter, Ian; Clarke, Laura; Parkinson, Helen; Harrison, Peter W; Faulconbridge, Adam; Cherubin, Luca; Burdett, Tony; Trigueros, Cesar; Patel, Minal J; Lucas, Christa; Hardy, Barry; Predan, Rok; Dokler, Joh; Brajnik, Maja; Keminer, Oliver; Pless, Ole; Gribbon, Philip; Claussen, Carsten; Ringwald, Annette; Kreisel, Beate; Courtney, Aidan; Allsopp, Timothy E

    2017-04-01

    A fast track "Hot Start" process was implemented to launch the European Bank for Induced Pluripotent Stem Cells (EBiSC) to provide early release of a range of established control and disease linked human induced pluripotent stem cell (hiPSC) lines. Established practice amongst consortium members was surveyed to arrive at harmonised and publically accessible Standard Operations Procedures (SOPs) for tissue procurement, bio-sample tracking, iPSC expansion, cryopreservation, qualification and distribution to the research community. These were implemented to create a quality managed foundational collection of lines and associated data made available for distribution. Here we report on the successful outcome of this experience and work flow for banking and facilitating access to an otherwise disparate European resource, with lessons to benefit the international research community. ETOC: The report focuses on the EBiSC experience of rapidly establishing an operational capacity to procure, bank and distribute a foundational collection of established hiPSC lines. It validates the feasibility and defines the challenges of harnessing and integrating the capability and productivity of centres across Europe using commonly available resources currently in the field. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  17. The ATLAS multi-user upgrade and potential applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mustapha, B.; Nolen, J. A.; Savard, G.

    With the recent integration of the CARIBU-EBIS charge breeder into the ATLAS accelerator system to provide for more pure and efficient charge breeding of radioactive beams, a multi-user upgrade of the ATLAS facility is being proposed to serve multiple users simultaneously. ATLAS was the first superconducting ion linac in the world and is the US DOE low-energy Nuclear Physics National User Facility. The proposed upgrade will take advantage of the continuous-wave nature of ATLAS and the pulsed nature of the EBIS charge breeder in order to simultaneously accelerate two beams with very close mass-to-charge ratios; one stable from the existingmore » ECR ion source and one radioactive from the newly commissioned EBIS charge breeder. In addition to enhancing the nuclear physics program, beam extraction at different points along the linac will open up the opportunity for other potential applications; for instance, material irradiation studies at ~ 1 MeV/u and isotope production at ~ 6 MeV/u or at the full ATLAS energy of ~ 15 MeV/u. The concept and proposed implementation of the ATLAS multi-user upgrade will be presented. Future plans to enhance the flexibility of this upgrade will also be presented.« less

  18. Adapting an Evidence-Based Intervention Targeting HIV-Infected Prisoners in Malaysia

    PubMed Central

    Copenhaver, Michael M.; Tunku, Noor; Ezeabogu, Ifeoma; Potrepka, Jessica; Zahari, Muhammad Muhsin A.; Kamarulzaman, Adeeba; Altice, Frederick L.

    2011-01-01

    HIV-infected prisoners in Malaysia represent a critical target population for secondary HIV risk reduction interventions and care. We report on the process and outcome of our formative research aimed at systematically selecting and adapting an EBI designed to reduce secondary HIV risk and improve adherence to antiretroviral therapy among soon-to-be-released HIV-infected prisoners. Our formative work involved a critical examination of established EBIs and associated published reports complemented by data elicited through structured interviews and focus groups with key stakeholders, members of the target population, and their family members. Based on all information, we adapted the Holistic Health Recovery Program targeting people living with HIV (HHRP+), an EBI, to consist of eight 2-hour sessions that cover a range of specified topics so that participants may individually apply intervention content as needed to accommodate their particular substance abuse, HIV risk, and antiretroviral adherence issues. This study provides a complete example of the process of selecting and adapting an EBI—taking into account both empirical evidence and input from target organization stakeholders and target population members and their families—for use in real world prison settings where high-risk populations are concentrated. PMID:21860786

  19. The ATLAS multi-user upgrade and potential applications

    NASA Astrophysics Data System (ADS)

    Mustapha, B.; Nolen, J. A.; Savard, G.; Ostroumov, P. N.

    2017-12-01

    With the recent integration of the CARIBU-EBIS charge breeder into the ATLAS accelerator system to provide for more pure and efficient charge breeding of radioactive beams, a multi-user upgrade of the ATLAS facility is being proposed to serve multiple users simultaneously. ATLAS was the first superconducting ion linac in the world and is the US DOE low-energy Nuclear Physics National User Facility. The proposed upgrade will take advantage of the continuous-wave nature of ATLAS and the pulsed nature of the EBIS charge breeder in order to simultaneously accelerate two beams with very close mass-to-charge ratios; one stable from the existing ECR ion source and one radioactive from the newly commissioned EBIS charge breeder. In addition to enhancing the nuclear physics program, beam extraction at different points along the linac will open up the opportunity for other potential applications; for instance, material irradiation studies at ~1 MeV/u, isotope production and radiobiological studies at ~6 MeV/u and at the full ATLAS energy of ~15 MeV/u. The concept and proposed implementation of the ATLAS multi-user upgrade will be discussed. Future plans to enhance the flexibility of this upgrade will be presented.

  20. Application and development of ion-source technology for radiation-effects testing of electronics

    NASA Astrophysics Data System (ADS)

    Kalvas, T.; Javanainen, A.; Kettunen, H.; Koivisto, H.; Tarvainen, O.; Virtanen, A.

    2017-09-01

    Studies of heavy-ion induced single event effect (SEE) on space electronics are necessary to verify the operation of the components in the harsh radiation environment. These studies are conducted by using high-energy heavy-ion beams to simulate the radiation effects in space. The ion beams are accelerated as so-called ion cocktails, containing several ion beam species with similar mass-to-charge ratio, covering a wide range of linear energy transfer (LET) values also present in space. The use of cocktails enables fast switching between beam species during testing. Production of these high-energy ion cocktails poses challenging requirements to the ion sources because in most laboratories reaching the necessary beam energies requires very high charge state ions. There are two main technologies producing these beams: The electron beam ion source EBIS and the electron cyclotron resonance ion source ECRIS. The EBIS is most suitable for pulsed accelerators, while ECRIS is most suitable for use with cyclotrons, which are the most common accelerators used in these applications. At the Accelerator Laboratory of the University of Jyväskylä (JYFL), radiation effects testing is currently performed using a K130 cyclotron and a 14 GHz ECRIS at a beam energy of 9.3 MeV/u. A new 18 GHz ECRIS, pushing the limits of the normal conducting ECR technology is under development at JYFL. The performances of existing 18 GHz ion sources have been compared, and based on this analysis, a 16.2 MeV/u beam cocktail with 1999 MeV 126Xe44+ being the most challenging component to has been chosen for development at JYFL. The properties of the suggested beam cocktail are introduced and discussed.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Somerville, Chris

    Berkeley Lab's Chris Somerville is a leading authority on the structure and function of plant cell walls, which comprise most of the body mass of higher plants. He views the knowledge of cell wall structure and function as furthering the development of plants with improved usefulness: these plants are strong potential sources of renewable materials and biofuel feedstocks. His scientific expertise defines an ideal match of his interest - in the development of cellulosic and other solar-to-fuel science - with his recent appointment as Director of the Energy Biosciences Institute (EBI). With colleagues in biology, physical sciences, engineering, and environmentalmore » and the social sciences, he now leads the EBI multidisciplinary teams' research efforts to develop next-generation, carbon-neutral transportation fuels.« less

  2. EBI metagenomics--a new resource for the analysis and archiving of metagenomic data.

    PubMed

    Hunter, Sarah; Corbett, Matthew; Denise, Hubert; Fraser, Matthew; Gonzalez-Beltran, Alejandra; Hunter, Christopher; Jones, Philip; Leinonen, Rasko; McAnulla, Craig; Maguire, Eamonn; Maslen, John; Mitchell, Alex; Nuka, Gift; Oisel, Arnaud; Pesseat, Sebastien; Radhakrishnan, Rajesh; Rocca-Serra, Philippe; Scheremetjew, Maxim; Sterk, Peter; Vaughan, Daniel; Cochrane, Guy; Field, Dawn; Sansone, Susanna-Assunta

    2014-01-01

    Metagenomics is a relatively recently established but rapidly expanding field that uses high-throughput next-generation sequencing technologies to characterize the microbial communities inhabiting different ecosystems (including oceans, lakes, soil, tundra, plants and body sites). Metagenomics brings with it a number of challenges, including the management, analysis, storage and sharing of data. In response to these challenges, we have developed a new metagenomics resource (http://www.ebi.ac.uk/metagenomics/) that allows users to easily submit raw nucleotide reads for functional and taxonomic analysis by a state-of-the-art pipeline, and have them automatically stored (together with descriptive, standards-compliant metadata) in the European Nucleotide Archive.

  3. Metagenomic sequence of saline desert microbiota from wild ass sanctuary, Little Rann of Kutch, Gujarat, India.

    PubMed

    Patel, Rajesh; Mevada, Vishal; Prajapati, Dhaval; Dudhagara, Pravin; Koringa, Prakash; Joshi, C G

    2015-03-01

    We report Metagenome from the saline desert soil sample of Little Rann of Kutch, Gujarat State, India. Metagenome consisted of 633,760 sequences with size 141,307,202 bp and 56% G + C content. Metagenome sequence data are available at EBI under EBI Metagenomics database with accession no. ERP005612. Community metagenomics revealed total 1802 species belonged to 43 different phyla with dominating Marinobacter (48.7%) and Halobacterium (4.6%) genus in bacterial and archaeal domain respectively. Remarkably, 18.2% sequences in a poorly characterized group and 4% gene for various stress responses along with versatile presence of commercial enzyme were evident in a functional metagenome analysis.

  4. EBI metagenomics—a new resource for the analysis and archiving of metagenomic data

    PubMed Central

    Hunter, Sarah; Corbett, Matthew; Denise, Hubert; Fraser, Matthew; Gonzalez-Beltran, Alejandra; Hunter, Christopher; Jones, Philip; Leinonen, Rasko; McAnulla, Craig; Maguire, Eamonn; Maslen, John; Mitchell, Alex; Nuka, Gift; Oisel, Arnaud; Pesseat, Sebastien; Radhakrishnan, Rajesh; Rocca-Serra, Philippe; Scheremetjew, Maxim; Sterk, Peter; Vaughan, Daniel; Cochrane, Guy; Field, Dawn; Sansone, Susanna-Assunta

    2014-01-01

    Metagenomics is a relatively recently established but rapidly expanding field that uses high-throughput next-generation sequencing technologies to characterize the microbial communities inhabiting different ecosystems (including oceans, lakes, soil, tundra, plants and body sites). Metagenomics brings with it a number of challenges, including the management, analysis, storage and sharing of data. In response to these challenges, we have developed a new metagenomics resource (http://www.ebi.ac.uk/metagenomics/) that allows users to easily submit raw nucleotide reads for functional and taxonomic analysis by a state-of-the-art pipeline, and have them automatically stored (together with descriptive, standards-compliant metadata) in the European Nucleotide Archive. PMID:24165880

  5. E-MSD: an integrated data resource for bioinformatics.

    PubMed

    Velankar, S; McNeil, P; Mittard-Runte, V; Suarez, A; Barrell, D; Apweiler, R; Henrick, K

    2005-01-01

    The Macromolecular Structure Database (MSD) group (http://www.ebi.ac.uk/msd/) continues to enhance the quality and consistency of macromolecular structure data in the worldwide Protein Data Bank (wwPDB) and to work towards the integration of various bioinformatics data resources. One of the major obstacles to the improved integration of structural databases such as MSD and sequence databases like UniProt is the absence of up to date and well-maintained mapping between corresponding entries. We have worked closely with the UniProt group at the EBI to clean up the taxonomy and sequence cross-reference information in the MSD and UniProt databases. This information is vital for the reliable integration of the sequence family databases such as Pfam and Interpro with the structure-oriented databases of SCOP and CATH. This information has been made available to the eFamily group (http://www.efamily.org.uk/) and now forms the basis of the regular interchange of information between the member databases (MSD, UniProt, Pfam, Interpro, SCOP and CATH). This exchange of annotation information has enriched the structural information in the MSD database with annotation from wider sequence-oriented resources. This work was carried out under the 'Structure Integration with Function, Taxonomy and Sequences (SIFTS)' initiative (http://www.ebi.ac.uk/msd-srv/docs/sifts) in the MSD group.

  6. Enhanced Therapeutic Potential of Nano-Curcumin Against Subarachnoid Hemorrhage-Induced Blood-Brain Barrier Disruption Through Inhibition of Inflammatory Response and Oxidative Stress.

    PubMed

    Zhang, Zong-Yong; Jiang, Ming; Fang, Jie; Yang, Ming-Feng; Zhang, Shuai; Yin, Yan-Xin; Li, Da-Wei; Mao, Lei-Lei; Fu, Xiao-Yan; Hou, Ya-Jun; Fu, Xiao-Ting; Fan, Cun-Dong; Sun, Bao-Liang

    2017-01-01

    Curcumin and nano-curcumin both exhibit neuroprotective effects in early brain injury (EBI) after experimental subarachnoid hemorrhage (SAH). However, the mechanism that whether curcumin and its nanoparticles affect the blood-brain barrier (BBB) following SAH remains unclear. This study investigated the effect of curcumin and the poly(lactide-co-glycolide) (PLGA)-encapsulated curcumin nanoparticles (Cur-NPs) on BBB disruption and evaluated the possible mechanism underlying BBB dysfunction in EBI using the endovascular perforation rat SAH model. The results indicated that Cur-NPs showed enhanced therapeutic effects than that of curcumin in improving neurological function, reducing brain water content, and Evans blue dye extravasation after SAH. Mechanically, Cur-NPs attenuated BBB dysfunction after SAH by preventing the disruption of tight junction protein (ZO-1, occludin, and claudin-5). Cur-NPs also up-regulated glutamate transporter-1 and attenuated glutamate concentration of cerebrospinal fluid following SAH. Moreover, inhibition of inflammatory response and microglia activation both contributed to Cur-NPs' protective effects. Additionally, Cur-NPs markedly suppressed SAH-mediated oxidative stress and eventually reversed SAH-induced cell apoptosis in rats. Our findings revealed that the strategy of using Cur-NPs could be a promising way in improving neurological function in EBI after experimental rat SAH.

  7. Overexpression of Epstein-Barr virus-induced gene 3 protein (EBI3) in MRL/lpr mice suppresses their lupus nephritis by activating regulatory T cells.

    PubMed

    Shinsuke, Nishimura; Hiroshi, Inoue

    2013-11-01

    To identify the effect of an imbalance of Th1/Th2 cytokines on the development of autoimmune glomerulonephritis (lupus nephritis), we studied the modification of pathological changes in diffuse proliferative glomerulonephritis (DPGN) and membranous glomerulonephritis (MGN) in MRL/lpr mice, which are animal models of systemic lupus erythematosus (SLE). Transgenic MRL/lpr mice (Tg) that overexpressed Epstein--Barr virus-induced gene 3 (EBI3) showed almost normal renal function, which was demonstrated by healing of glomerulonephritis upon renal histology, as compared to the wild-type MRL/lpr (Wt) mice. The levels of anti-dsDNA antibodies and IgE decreased in the Tg mice compared to Wt mice. Quantitative real-time PCR indicated an increase in the mRNA levels of FoxP3, and a decrease in that of IFNγ in the splenocytes of Tg mice as compared to Wt mice. In addition, flow cytometric analysis showed an increase in CD4(+)CD25(+)FoxP3(+)-T cells in the former, as compared to the latter. Our findings suggest that EBI3-overexpression in MRL/lpr mice induces generation of regulatory T cells, which causes suppression of autoimmune and inflammatory reactions by affecting the Th1/Th2 cytokine balance.

  8. The European Bioinformatics Institute in 2017: data coordination and integration

    PubMed Central

    Cochrane, Guy; Apweiler, Rolf; Birney, Ewan

    2018-01-01

    Abstract The European Bioinformatics Institute (EMBL-EBI) supports life-science research throughout the world by providing open data, open-source software and analytical tools, and technical infrastructure (https://www.ebi.ac.uk). We accommodate an increasingly diverse range of data types and integrate them, so that biologists in all disciplines can explore life in ever-increasing detail. We maintain over 40 data resources, many of which are run collaboratively with partners in 16 countries (https://www.ebi.ac.uk/services). Submissions continue to increase exponentially: our data storage has doubled in less than two years to 120 petabytes. Recent advances in cellular imaging and single-cell sequencing techniques are generating a vast amount of high-dimensional data, bringing to light new cell types and new perspectives on anatomy. Accordingly, one of our main focus areas is integrating high-quality information from bioimaging, biobanking and other types of molecular data. This is reflected in our deep involvement in Open Targets, stewarding of plant phenotyping standards (MIAPPE) and partnership in the Human Cell Atlas data coordination platform, as well as the 2017 launch of the Omics Discovery Index. This update gives a birds-eye view of EMBL-EBI’s approach to data integration and service development as genomics begins to enter the clinic. PMID:29186510

  9. Scan direction induced charging dynamics and the application for detection of gate to S/D shorts in logic devices

    NASA Astrophysics Data System (ADS)

    Lei, Ming; Tian, Qing; Wu, Kevin; Zhao, Yan

    2016-03-01

    Gate to source/drain (S/D) short is the most common and detrimental failure mechanism for advanced process technology development in Metal-Oxide-Semiconductor-Field-Effect-Transistor (MOSFET) device manufacturing. Especially for sub-1Xnm nodes, MOSFET device is more vulnerable to gate-S/D shorts due to the aggressive scaling. The detection of this kind of electrical short defect is always challenging for in-line electron beam inspection (EBI), especially new shorting mechanisms on atomic scale due to new material/process flow implementation. The second challenge comes from the characterization of the shorts including identification of the exact shorting location. In this paper, we demonstrate unique scan direction induced charging dynamics (SDCD) phenomenon which stems from the transistor level response from EBI scan at post metal contact chemical-mechanical planarization (CMP) layers. We found that SDCD effect is exceptionally useful for gate-S/D short induced voltage contrast (VC) defect detection, especially for identification of shorting locations. The unique SDCD effect signatures of gate-S/D shorts can be used as fingerprint for ground true shorting defect detection. Correlation with other characterization methods on the same defective location from EBI scan shows consistent results from various shorting mechanism. A practical work flow to implement the application of SDCD effect for in-line EBI monitor of critical gate-S/D short defects is also proposed, together with examples of successful application use cases which mostly focus on static random-access memory (SRAM) array regions. Although the capability of gate-S/D short detection as well as expected device response is limited to passing transistors and pull-down transistors due to the design restriction from standard 6-cell SRAM structure, SDCD effect is proven to be very effective for gate-S/D short induced VC defect detection as well as yield learning for advanced technology development.

  10. Oral Escherichia coli Colonization Factor Antigen I (CFA/I) Fimbriae Ameliorate Arthritis via IL-35, not IL-27

    PubMed Central

    Kochetkova, Irina; Thornburg, Theresa; Callis, Gayle; Holderness, Kathryn; Maddaloni, Massimo; Pascual, David W.

    2014-01-01

    A Salmonella therapeutic expressing enterotoxigenic E. coli colonization factor antigen I (CFA/I) fimbriae protects against collagen-induced arthritis (CIA) by eliciting two regulatory T cell (Treg) subsets: TGF-β-producing Foxp3−CD39+CD4+ and IL-10-producing Foxp3+CD39+CD4+ T cells. However, it is unclear if CFA/I fimbriae alone are protective, and if other regulatory cytokines are involved especially in the context for the EBI3-sharing cytokines, Treg-derived IL-35 and APC-derived IL-27, both capable of suppressing Th17 cells and regulating autoimmune diseases. Subsequent evaluation revealed that a single oral dose of purified, soluble CFA/I fimbriae protected against CIA as effectively as Salmonella-CFA/I, and found Foxp3+CD39+CD4+ T cells as the source of secreted IL-35, whereas IL-27 production by CD11c+ cells was inhibited. Inquiring into their relevance, CFA/I fimbriae-treated IL-27 receptor-deficient (WSX-1−/−) mice were equally protected against CIA as wild-type mice suggesting a limited role for IL-27. In contrast, CFA/I fimbriae-mediated protection was abated in EBI3−/− mice accompanied by the loss of TGF-β- and IL-10-producing Tregs. Adoptive transfer of B6 CD39+CD4+ T cells to EBI3−/− mice with concurrent CFA/I plus IL-35 treatment effectively stimulated Tregs suppressing proinflammatory CII-specific Th cells. Opposingly, recipients co-transferred with B6 and EBI3−/− CD39+CD4+ T cells and treated with CFA/I plus IL-35 failed in protecting mice implicating the importance for endogenous IL-35 to confer CFA/I-mediated protection. Thus, CFA/I fimbriae stimulate IL-35 required for the co-induction of TGF-β and IL-10. PMID:24337375

  11. A rule-based ontological framework for the classification of molecules

    PubMed Central

    2014-01-01

    Background A variety of key activities within life sciences research involves integrating and intelligently managing large amounts of biochemical information. Semantic technologies provide an intuitive way to organise and sift through these rapidly growing datasets via the design and maintenance of ontology-supported knowledge bases. To this end, OWL—a W3C standard declarative language— has been extensively used in the deployment of biochemical ontologies that can be conveniently organised using the classification facilities of OWL-based tools. One of the most established ontologies for the chemical domain is ChEBI, an open-access dictionary of molecular entities that supplies high quality annotation and taxonomical information for biologically relevant compounds. However, ChEBI is being manually expanded which hinders its potential to grow due to the limited availability of human resources. Results In this work, we describe a prototype that performs automatic classification of chemical compounds. The software we present implements a sound and complete reasoning procedure of a formalism that extends datalog and builds upon an off-the-shelf deductive database system. We capture a wide range of chemical classes that are not expressible with OWL-based formalisms such as cyclic molecules, saturated molecules and alkanes. Furthermore, we describe a surface ‘less-logician-like’ syntax that allows application experts to create ontological descriptions of complex biochemical objects without prior knowledge of logic. In terms of performance, a noticeable improvement is observed in comparison with previous approaches. Our evaluation has discovered subsumptions that are missing from the manually curated ChEBI ontology as well as discrepancies with respect to existing subclass relations. We illustrate thus the potential of an ontology language suitable for the life sciences domain that exhibits a favourable balance between expressive power and practical feasibility. Conclusions Our proposed methodology can form the basis of an ontology-mediated application to assist biocurators in the production of complete and error-free taxonomies. Moreover, such a tool could contribute to a more rapid development of the ChEBI ontology and to the efforts of the ChEBI team to make annotated chemical datasets available to the public. From a modelling point of view, our approach could stimulate the adoption of a different and expressive reasoning paradigm based on rules for which state-of-the-art and highly optimised reasoners are available; it could thus pave the way for the representation of a broader spectrum of life sciences and biomedical knowledge. PMID:24735706

  12. A rule-based ontological framework for the classification of molecules.

    PubMed

    Magka, Despoina; Krötzsch, Markus; Horrocks, Ian

    2014-01-01

    A variety of key activities within life sciences research involves integrating and intelligently managing large amounts of biochemical information. Semantic technologies provide an intuitive way to organise and sift through these rapidly growing datasets via the design and maintenance of ontology-supported knowledge bases. To this end, OWL-a W3C standard declarative language- has been extensively used in the deployment of biochemical ontologies that can be conveniently organised using the classification facilities of OWL-based tools. One of the most established ontologies for the chemical domain is ChEBI, an open-access dictionary of molecular entities that supplies high quality annotation and taxonomical information for biologically relevant compounds. However, ChEBI is being manually expanded which hinders its potential to grow due to the limited availability of human resources. In this work, we describe a prototype that performs automatic classification of chemical compounds. The software we present implements a sound and complete reasoning procedure of a formalism that extends datalog and builds upon an off-the-shelf deductive database system. We capture a wide range of chemical classes that are not expressible with OWL-based formalisms such as cyclic molecules, saturated molecules and alkanes. Furthermore, we describe a surface 'less-logician-like' syntax that allows application experts to create ontological descriptions of complex biochemical objects without prior knowledge of logic. In terms of performance, a noticeable improvement is observed in comparison with previous approaches. Our evaluation has discovered subsumptions that are missing from the manually curated ChEBI ontology as well as discrepancies with respect to existing subclass relations. We illustrate thus the potential of an ontology language suitable for the life sciences domain that exhibits a favourable balance between expressive power and practical feasibility. Our proposed methodology can form the basis of an ontology-mediated application to assist biocurators in the production of complete and error-free taxonomies. Moreover, such a tool could contribute to a more rapid development of the ChEBI ontology and to the efforts of the ChEBI team to make annotated chemical datasets available to the public. From a modelling point of view, our approach could stimulate the adoption of a different and expressive reasoning paradigm based on rules for which state-of-the-art and highly optimised reasoners are available; it could thus pave the way for the representation of a broader spectrum of life sciences and biomedical knowledge.

  13. Reducing Our Carbon Footprint: Converting Plants to Fuel (LBNL Science at the Theater)

    ScienceCinema

    Somerville, Chris [Univ. of California, Berkeley, CA (United States)

    2018-05-23

    Berkeley Lab's Chris Somerville is a leading authority on the structure and function of plant cell walls, which comprise most of the body mass of higher plants. He views the knowledge of cell wall structure and function as furthering the development of plants with improved usefulness: these plants are strong potential sources of renewable materials and biofuel feedstocks. His scientific expertise defines an ideal match of his interest - in the development of cellulosic and other solar-to-fuel science - with his recent appointment as Director of the Energy Biosciences Institute (EBI). With colleagues in biology, physical sciences, engineering, and environmental and the social sciences, he now leads the EBI multidisciplinary teams' research efforts to develop next-generation, carbon-neutral transportation fuels.

  14. ProtVista: visualization of protein sequence annotations.

    PubMed

    Watkins, Xavier; Garcia, Leyla J; Pundir, Sangya; Martin, Maria J

    2017-07-01

    ProtVista is a comprehensive visualization tool for the graphical representation of protein sequence features in the UniProt Knowledgebase, experimental proteomics and variation public datasets. The complexity and relationships in this wealth of data pose a challenge in interpretation. Integrative visualization approaches such as provided by ProtVista are thus essential for researchers to understand the data and, for instance, discover patterns affecting function and disease associations. ProtVista is a JavaScript component released as an open source project under the Apache 2 License. Documentation and source code are available at http://ebi-uniprot.github.io/ProtVista/ . martin@ebi.ac.uk. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.

  15. Performance on the low charge state laser ion source in BNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Okamura, M.; Alessi, J.; Beebe, E.

    On March 2014, a Laser Ion Source (LIS) was commissioned which delivers high-brightness, low-charge-state heavy ions for the hadron accelerator complex in Brookhaven National Laboratory (BNL). Since then, the LIS has provided many heavy ion species successfully. The low-charge-state (mostly singly charged) beams are injected to the Electron Beam Ion Source (EBIS), where ions are then highly ionized to fit to the following accelerator’s Q/M acceptance, like Au 32+. Recently we upgraded the LIS to be able to provide two different beams into EBIS on a pulse-to-pulse basis. Now the LIS is simultaneously providing beams for both the Relativistic Heavymore » Ion Collider (RHIC) and NASA Space Radiation Laboratory (NSRL).« less

  16. The Ensembl REST API: Ensembl Data for Any Language

    PubMed Central

    Yates, Andrew; Beal, Kathryn; Keenan, Stephen; McLaren, William; Pignatelli, Miguel; Ritchie, Graham R. S.; Ruffier, Magali; Taylor, Kieron; Vullo, Alessandro; Flicek, Paul

    2015-01-01

    Motivation: We present a Web service to access Ensembl data using Representational State Transfer (REST). The Ensembl REST server enables the easy retrieval of a wide range of Ensembl data by most programming languages, using standard formats such as JSON and FASTA while minimizing client work. We also introduce bindings to the popular Ensembl Variant Effect Predictor tool permitting large-scale programmatic variant analysis independent of any specific programming language. Availability and implementation: The Ensembl REST API can be accessed at http://rest.ensembl.org and source code is freely available under an Apache 2.0 license from http://github.com/Ensembl/ensembl-rest. Contact: ayates@ebi.ac.uk or flicek@ebi.ac.uk Supplementary information: Supplementary data are available at Bioinformatics online. PMID:25236461

  17. Inhibitory effects of omega-3 fatty acids on early brain injury after subarachnoid hemorrhage in rats: Possible involvement of G protein-coupled receptor 120/β-arrestin2/TGF-β activated kinase-1 binding protein-1 signaling pathway.

    PubMed

    Yin, Jia; Li, Haiying; Meng, Chengjie; Chen, Dongdong; Chen, Zhouqing; Wang, Yibin; Wang, Zhong; Chen, Gang

    2016-06-01

    Omega-3 fatty acids have been reported to improve neuron functions during aging and in patients affected by mild cognitive impairment, and mediate potent anti-inflammatory via G protein-coupled receptor 120 (GPR120) signal pathway. Neuron dysfunction and inflammatory response also contributed to the progression of subarachnoid hemorrhage (SAH)-induced early brain injury (EBI). This study was to examine the effects of omega-3 fatty acids on SAH-induced EBI. Two weeks before SAH, 30% Omega-3 fatty acids was administered by oral gavage at 1g/kg body weight once every 24h. Specific siRNA for GPR120 was exploited. Terminal deoxynucleotidyl transferase dUTP nick end labeling, fluoro-Jade B staining, and neurobehavioral scores and brain water content test showed that omega-3 fatty acids effectively suppressed SAH-induced brain cell apoptosis and neuronal degradation, behavioral impairment, and brain edema. Western blot, immunoprecipitation, and electrophoretic mobility shift assays results showed that omega-3 fatty acids effectively suppressed SAH-induced elevation of inflammatory factors, including cyclooxygenase-2, monocyte chemoattractant protein-1, and inducible nitric oxide synthase. In addition, omega-3 fatty acids could inhibit phosphorylation of transforming growth factor β activated kinase-1 (TAK1), MEK4, c-Jun N-terminal kinase, and IkappaB kinase as well as activation of nuclear factor kappa B through regulating GPR120/β-arrestin2/TAK1 binding protein-1 pathway. Furthermore, siRNA-induced GPR120 silencing blocked the protective effects of omega-3 fatty acids. Here, we show that stimulation of GPR120 with omega-3 fatty acids pretreatment causes anti-apoptosis and anti-inflammatory effects via β-arrestin2/TAK1 binding protein-1/TAK1 pathway in the brains of SAH rats. Fish omega-3 fatty acids as part of a daily diet may reduce EBI in an experimental rat model of SAH. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Looking northeast from Test Stand 'A' superstructure towards Test Stand ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Looking northeast from Test Stand 'A' superstructure towards Test Stand 'D' tower (4223/E-24, left background), Test Stand 'C' tower (4217/E-18, center), and Test Stand 'B' (4215/E-16, right foreground). - Jet Propulsion Laboratory Edwards Facility, Edwards Air Force Base, Boron, Kern County, CA

  19. Theoretical and Experimental Research on a Millimeter-Wavelength Free-Electron Laser

    DTIC Science & Technology

    1989-09-01

    Plauma Sci. vol. PS-3, pp. 1-5, 1975. off (Fig. 7); this may be due to the TEo2 cutoff of the 5 cm [5] A. Grossman and T. C. Marshall, "Orbits of a test...from maycor (a machineable glass ), in the form of a N ihin-walled cone. Thermistors attached to the cone de-N 1- v/ " liver a signal which unbalances a...0.7; this is given by using a calorimeter cone fabricated of "Macor." a ma- eBI, nc chineable glass with high absorption at millimeter wave- vl = (eB

  20. Optimizing charge breeding techniques for ISOL facilities in Europe: Conclusions from the EMILIE project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Delahaye, P., E-mail: delahaye@ganil.fr; Jardin, P.; Maunoury, L.

    The present paper summarizes the results obtained from the past few years in the framework of the Enhanced Multi-Ionization of short-Lived Isotopes for Eurisol (EMILIE) project. The EMILIE project aims at improving the charge breeding techniques with both Electron Cyclotron Resonance Ion Sources (ECRIS) and Electron Beam Ion Sources (EBISs) for European Radioactive Ion Beam (RIB) facilities. Within EMILIE, an original technique for debunching the beam from EBIS charge breeders is being developed, for making an optimal use of the capabilities of CW post-accelerators of the future facilities. Such a debunching technique should eventually resolve duty cycle and time structuremore » issues which presently complicate the data-acquisition of experiments. The results of the first tests of this technique are reported here. In comparison with charge breeding with an EBIS, the ECRIS technique had lower performance in efficiency and attainable charge state for metallic ion beams and also suffered from issues related to beam contamination. In recent years, improvements have been made which significantly reduce the differences between the two techniques, making ECRIS charge breeding more attractive especially for CW machines producing intense beams. Upgraded versions of the Phoenix charge breeder, originally developed by LPSC, will be used at SPES and GANIL/SPIRAL. These two charge breeders have benefited from studies undertaken within EMILIE, which are also briefly summarized here.« less

  1. Identification of bacterial endophytes associated with traditional medicinal plant Tridax procumbens Linn.

    PubMed

    Preveena, Jagadesan; Bhore, Subhash J

    2013-01-01

    In traditional medicine, Tridax procumbens Linn. is used in the treatment of injuries and wounds. The bacterial endophytes (BEs) of medicinal plants could produce medicinally important metabolites found in their hosts; and hence, the involvement of BEs in conferring wound healing properties to T. Procumbens cannot be ruled out. But, we do not know which types of BEs are associated with T. Procumbens. The objective of this study was to investigate the fast growing and cultivable BEs associated with T. procumbens. Leaves and stems of healthy T. Procumbens plants were collected and cultivable BEs were isolated from surface-sterilized leaf and stem tissue samples using Luria-Bertani (LB) agar (medium) at standard conditions. A polymerase chain reaction was employed to amplify 16S rRNA coding gene fragments from the isolates. Cultivable endophytic bacterial isolates (EBIs) were identified using 16S rRNA gene nucleotide sequence similarity based method of bacterial identification. Altogether, 50 culturable EBIs were isolated. 16S rRNA gene nucleotide sequences analysis using the Basic Local Alignment Search Tool (BLAST) revealed identities of the EBIs. Analysis reveals that cultivable Bacillus spp., Cronobacter sakazakii, Enterobacter spp., Lysinibacillus sphaericus, Pantoea spp., Pseudomonas spp. and Terribacillus saccharophilus are associated with T. Procumbens. Based on the results, we conclude that 24 different types of culturable BEs are associated with traditionally used medicinal plant, T. Procumbens, and require further study.

  2. Adaptation of a U.S. evidence-based Positive Prevention intervention for youth living with HIV/AIDS in Kinshasa, Democratic Republic of the Congo

    PubMed Central

    Parker, L.; Maman, S.; Pettifor, A.; Chalachala, J.L.; Edmonds, A.; Golin, C.E.; Moracco, K.; Behets, F.

    2013-01-01

    Effective HIV prevention programs for people living with HIV/AIDS (PLWH) are important to reduce new infections and to ensure PLWH remain healthy. This paper describes the systematic adaptation of a U.S.-developed Evidence Based Intervention (EBI) using the Centers for Disease Control and Prevention (CDC) Map of Adaption Process for use at a Pediatric Hospital in Kinshasa, Democratic Republic of the Congo (DRC). The adapted intervention, Supporting Youth and Motivating Positive Action or SYMPA, a six-session risk reduction intervention targeted for youth living with HIV/AIDS (YLWH) in Kinshasa was adapted from the Healthy Living Project and guided by the Social Action Theory. This paper describes the process of implementing the first four steps of the ADAPT framework (Assess, Select, Prepare, and Pilot). Our study has shown that an EBI developed and implemented in the U.S. can be adapted successfully for a different target population in a low-resource context through an iterative process following the CDC ADAPT framework. This process included reviewing existing literature, adapting and adding components, and focusing on increasing staff capacity. This paper provides a rare, detailed description of the adaptation process and may aid organizations seeking to adapt and implement HIV prevention EBIs in sub-Saharan Africa and beyond. PMID:23063699

  3. Measurement equivalence: A non-technical primer on categorical multi-group confirmatory factor analysis in school psychology.

    PubMed

    Pendergast, Laura L; von der Embse, Nathaniel; Kilgus, Stephen P; Eklund, Katie R

    2017-02-01

    Evidence-based interventions (EBIs) have become a central component of school psychology research and practice, but EBIs are dependent upon the availability and use of evidence-based assessments (EBAs) with diverse student populations. Multi-group confirmatory factor analysis (MG-CFA) is an analytical tool that can be used to examine the validity and measurement equivalence/invariance of scores across diverse groups. The objective of this article is to provide a conceptual and procedural overview of categorical MG-CFA, as well as an illustrated example based on data from the Social and Academic Behavior Risk Screener (SABRS) - a tool designed for use in school-based interventions. This article serves as a non-technical primer on the topic of MG-CFA with ordinal (rating scale) data and does so through the framework of examining equivalence of measures used for EBIs within multi-tiered models - an understudied topic. To go along with the illustrated example, we have provided supplementary files that include sample data, Mplus input code, and an annotated guide for understanding the input code (http://dx.doi.org/10.1016/j.jsp.2016.11.002). Data needed to reproduce analyses in this article are available as supplemental materials (online only) in the Appendix of this article. Copyright © 2016 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  4. Characterization of photocathode dark current vs. temperature in image intensifier tube modules and intensified televisions

    NASA Astrophysics Data System (ADS)

    Bender, Edward J.; Wood, Michael V.; Hart, Steve; Heim, Gerald B.; Torgerson, John A.

    2004-10-01

    Image intensifiers (I2) have gained wide acceptance throughout the Army as the premier nighttime mobility sensor for the individual soldier, with over 200,000 fielded systems. There is increasing need, however, for such a sensor with a video output, so that it can be utilized in remote vehicle platforms, and/or can be electronically fused with other sensors. The image-intensified television (I2TV), typically consisting of an image intensifier tube coupled via fiber optic to a solid-state imaging array, has been the primary solution to this need. I2TV platforms in vehicles, however, can generate high internal heat loads and must operate in high-temperature environments. Intensifier tube dark current, called "Equivalent Background Input" or "EBI", is not a significant factor at room temperature, but can seriously degrade image contrast and intra-scene dynamic range at such high temperatures. Cooling of the intensifier's photocathode is the only practical solution to this problem. The US Army RDECOM CERDEC Night Vision & Electronic Sensors Directorate (NVESD) and Ball Aerospace have collaborated in the reported effort to more rigorously characterize intensifier EBI versus temperature. NVESD performed non-imaging EBI measurements of Generation 2 and 3 tube modules over a large range of ambient temperature, while Ball performed an imaging evaluation of Generation 3 I2TVs over a similar temperature range. The findings and conclusions of this effort are presented.

  5. E-MSD: an integrated data resource for bioinformatics

    PubMed Central

    Velankar, S.; McNeil, P.; Mittard-Runte, V.; Suarez, A.; Barrell, D.; Apweiler, R.; Henrick, K.

    2005-01-01

    The Macromolecular Structure Database (MSD) group (http://www.ebi.ac.uk/msd/) continues to enhance the quality and consistency of macromolecular structure data in the worldwide Protein Data Bank (wwPDB) and to work towards the integration of various bioinformatics data resources. One of the major obstacles to the improved integration of structural databases such as MSD and sequence databases like UniProt is the absence of up to date and well-maintained mapping between corresponding entries. We have worked closely with the UniProt group at the EBI to clean up the taxonomy and sequence cross-reference information in the MSD and UniProt databases. This information is vital for the reliable integration of the sequence family databases such as Pfam and Interpro with the structure-oriented databases of SCOP and CATH. This information has been made available to the eFamily group (http://www.efamily.org.uk/) and now forms the basis of the regular interchange of information between the member databases (MSD, UniProt, Pfam, Interpro, SCOP and CATH). This exchange of annotation information has enriched the structural information in the MSD database with annotation from wider sequence-oriented resources. This work was carried out under the ‘Structure Integration with Function, Taxonomy and Sequences (SIFTS)’ initiative (http://www.ebi.ac.uk/msd-srv/docs/sifts) in the MSD group. PMID:15608192

  6. Aerial shows Stennis test stands

    NASA Image and Video Library

    2004-04-16

    An aerial photo shows the B-1/B-2 Test Stand (foreground), A-2 Test Stand (middle) and A-1 Test Stand (back). The historic stands have been used to test engines used on every manned Apollo and space shuttle mission.

  7. 9. WEST SIDE, TEST STAND AND SUPERSTRUCTURE. TEST STAND 1B ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. WEST SIDE, TEST STAND AND SUPERSTRUCTURE. TEST STAND 1-B IN DISTANCE. Looking east. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  8. Using equivalence-based instruction to teach piano skills to college students.

    PubMed

    Griffith, Kristin R; Ramos, Amber L; Hill, Kelli E; Miguel, Caio F

    2018-04-01

    The purpose of the current study was to evaluate the effects of equivalence-based instruction (EBI) on the emergence of basic music reading and piano playing skills. Six female college students learned to identify three musical chord notations given their respective dictated names. Participants also learned to play chords on the piano following the dictated name of the chord, and to play the chords to a song on a keyboard. Results are consistent with past research, in that stimuli became substitutable for each other and acquired a common behavioral function. Data suggest that EBI was an effective and efficient procedure to teach adults to read musical notation, as well as play chords and a song on a piano keyboard. © 2018 Society for the Experimental Analysis of Behavior.

  9. Design study of primary ion provider for relativistic heavy ion collider electron beam ion source.

    PubMed

    Kondo, K; Kanesue, T; Tamura, J; Okamura, M

    2010-02-01

    Brookhaven National Laboratory has developed the new preinjector system, electron beam ion source (EBIS) for relativistic heavy ion collider (RHIC) and National Aeronautics and Space Administration Space Radiation Laboratory. Design of primary ion provider is an essential problem since it is required to supply beams with different ion species to multiple users simultaneously. The laser ion source with a defocused laser can provide a low charge state and low emittance ion beam, and is a candidate for the primary ion source for RHIC-EBIS. We show a suitable design with appropriate drift length and solenoid, which helps to keep sufficient total charge number with longer pulse length. The whole design of primary ion source, as well as optics arrangement, solid targets configuration and heating about target, is presented.

  10. The European Bioinformatics Institute’s data resources 2014

    PubMed Central

    Brooksbank, Catherine; Bergman, Mary Todd; Apweiler, Rolf; Birney, Ewan; Thornton, Janet

    2014-01-01

    Molecular Biology has been at the heart of the ‘big data’ revolution from its very beginning, and the need for access to biological data is a common thread running from the 1965 publication of Dayhoff’s ‘Atlas of Protein Sequence and Structure’ through the Human Genome Project in the late 1990s and early 2000s to today’s population-scale sequencing initiatives. The European Bioinformatics Institute (EMBL-EBI; http://www.ebi.ac.uk) is one of three organizations worldwide that provides free access to comprehensive, integrated molecular data sets. Here, we summarize the principles underpinning the development of these public resources and provide an overview of EMBL-EBI’s database collection to complement the reviews of individual databases provided elsewhere in this issue. PMID:24271396

  11. 2. EAST ELEVATION OF POWER PLANT TEST STAND (HORIZONTAL TEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. EAST ELEVATION OF POWER PLANT TEST STAND (HORIZONTAL TEST STAND REMNANTS OF BUILDING-BLANK WHITE WALL ONLY ORIGINAL REMAINS. - Marshall Space Flight Center, East Test Area, Power Plant Test Stand, Huntsville, Madison County, AL

  12. 28. HISTORIC VIEW OF A3 ROCKET IN TEST STAND NO. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    28. HISTORIC VIEW OF A-3 ROCKET IN TEST STAND NO. 3 AT KUMMERSDORF (THE LARGEST TEST STAND AT KUMMERSDORF). THE STAND WAS MOBILE, SINCE IT MOVED ALONG RAILS. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  13. Generation of magneto-immersed electron beams

    NASA Astrophysics Data System (ADS)

    Pikin, A.; Raparia, D.

    2018-05-01

    There are many applications of electron beams in accelerator facilities: for electron coolers, electron lenses, and electron beam ion sources (EBIS) to mention a few. Most of these applications require magnetic compression of the electron beam to reduce the beam radius with the goal of either matching the circulating ion beam (electron lenses and electron coolers) or increasing the ionization capability for the production of highly charged ions (EBIS). The magnetic compression of the electron beam comes at a cost of increasing share of the transverse component of energy and therefore increased angles of the electron trajectories to the longitudinal axis. Considering the effect of the magnetic mirror, it is highly desirable to produce a laminar electron beam in the electron gun. The analysis of electron guns with different configurations is given in this paper with emphasis on generating laminar electron beams.

  14. Ion Sources, Preinjectors and the Road to EBIS (459th Brookhaven Lecture)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alessi, James

    2010-07-21

    To meet the requirements of the scientific programs of the Relativistic Heavy Ion Collider and the NASA Space Radiation Lab, BNL's Collider-Accelerator Department needs a variety of ion sources. Although these sources are a relatively small and inexpensive part of an accelerator, they can have a big impact on the machine's overall performance. For the 459th Brookhaven Lecture, James Alessi will describe C-AD's long history of developing state-of-the-art ion sources for its accelerators, and its current process for source and pre-injector development. He will follow up with a discussion of the features and development status of EBIS, which, as themore » newest source and preinjector, is in the final stages of commissioning at the end of a five-year construction project.« less

  15. Chemical Entity Recognition and Resolution to ChEBI

    PubMed Central

    Grego, Tiago; Pesquita, Catia; Bastos, Hugo P.; Couto, Francisco M.

    2012-01-01

    Chemical entities are ubiquitous through the biomedical literature and the development of text-mining systems that can efficiently identify those entities are required. Due to the lack of available corpora and data resources, the community has focused its efforts in the development of gene and protein named entity recognition systems, but with the release of ChEBI and the availability of an annotated corpus, this task can be addressed. We developed a machine-learning-based method for chemical entity recognition and a lexical-similarity-based method for chemical entity resolution and compared them with Whatizit, a popular-dictionary-based method. Our methods outperformed the dictionary-based method in all tasks, yielding an improvement in F-measure of 20% for the entity recognition task, 2–5% for the entity-resolution task, and 15% for combined entity recognition and resolution tasks. PMID:25937941

  16. Nanojoint Formation between Ceramic Titanate Nanowires and Spot Melting of Metal Nanowires with Electron Beam.

    PubMed

    Bo, Arixin; Alarco, Jose; Zhu, Huaiyong; Waclawik, Eric R; Zhan, Haifei; Gu, YuanTong

    2017-03-15

    Construction of nanoarchitectures requires techniques like joint formation and trimming. For ceramic materials, however, it is extremely difficult to form nanojoints by conventional methods like merging. In this work, we demonstrate that ceramic titanate nanowires (NWs) can be joined by spot melting under electron beam (e-beam) irradiation (EBI). The irradiation fuses the contacted spot of titanate NWs yielding an intact nanojoint. Nanojoints with different morphologies can be produced. The joint structures consist of titanium dioxide (TiO 2 ) rutile, anatase, and titanate phases in the direction away from the e-beam melting spot. The titanate binds to anatase via a crystallographic matching coherent interface (the oxygen atoms at the interface are shared by the two phases) and the anatase solidly binds to the rutile joint. The resulting rutile joint is stable at high temperatures. Additionally, it is demonstrated that the heat production from EBI treated rutile can be utilized to break metal NWs (Ag, Cu, and Ni) apart by spot melting. The required e-beam intensity is considerably mild (75 pA/cm 2 ) which allows visual access and control over the NW melting. Direct melting of Ag and Cu is not applicable under EBI due to their high thermal conductivity even with high current density (500 pA/cm 2 ). Our findings reveal that ceramic nanojoint formation and spot melting at nanoscale are applicable if the properties of nanomaterials are understood and properly utilized.

  17. Identification of bacterial endophytes associated with traditional medicinal plant Tridax procumbens Linn.

    PubMed Central

    Preveena, Jagadesan; Bhore, Subhash J.

    2013-01-01

    Background: In traditional medicine, Tridax procumbens Linn. is used in the treatment of injuries and wounds. The bacterial endophytes (BEs) of medicinal plants could produce medicinally important metabolites found in their hosts; and hence, the involvement of BEs in conferring wound healing properties to T. Procumbens cannot be ruled out. But, we do not know which types of BEs are associated with T. Procumbens. Objective: The objective of this study was to investigate the fast growing and cultivable BEs associated with T. procumbens. Materials and Methods: Leaves and stems of healthy T. Procumbens plants were collected and cultivable BEs were isolated from surface-sterilized leaf and stem tissue samples using Luria-Bertani (LB) agar (medium) at standard conditions. A polymerase chain reaction was employed to amplify 16S rRNA coding gene fragments from the isolates. Cultivable endophytic bacterial isolates (EBIs) were identified using 16S rRNA gene nucleotide sequence similarity based method of bacterial identification. Results: Altogether, 50 culturable EBIs were isolated. 16S rRNA gene nucleotide sequences analysis using the Basic Local Alignment Search Tool (BLAST) revealed identities of the EBIs. Analysis reveals that cultivable Bacillus spp., Cronobacter sakazakii, Enterobacter spp., Lysinibacillus sphaericus, Pantoea spp., Pseudomonas spp. and Terribacillus saccharophilus are associated with T. Procumbens. Conclusion: Based on the results, we conclude that 24 different types of culturable BEs are associated with traditionally used medicinal plant, T. Procumbens, and require further study. PMID:24501447

  18. Novel view synthesis by interpolation over sparse examples

    NASA Astrophysics Data System (ADS)

    Liang, Bodong; Chung, Ronald C.

    2006-01-01

    Novel view synthesis (NVS) is an important problem in image rendering. It involves synthesizing an image of a scene at any specified (novel) viewpoint, given some images of the scene at a few sample viewpoints. The general understanding is that the solution should bypass explicit 3-D reconstruction of the scene. As it is, the problem has a natural tie to interpolation, despite that mainstream efforts on the problem have been adopting formulations otherwise. Interpolation is about finding the output of a function f(x) for any specified input x, given a few input-output pairs {(xi,fi):i=1,2,3,...,n} of the function. If the input x is the viewpoint, and f(x) is the image, the interpolation problem becomes exactly NVS. We treat the NVS problem using the interpolation formulation. In particular, we adopt the example-based everything or interpolation (EBI) mechanism-an established mechanism for interpolating or learning functions from examples. EBI has all the desirable properties of a good interpolation: all given input-output examples are satisfied exactly, and the interpolation is smooth with minimum oscillations between the examples. We point out that EBI, however, has difficulty in interpolating certain classes of functions, including the image function in the NVS problem. We propose an extension of the mechanism for overcoming the limitation. We also present how the extended interpolation mechanism could be used to synthesize images at novel viewpoints. Real image results show that the mechanism has promising performance, even with very few example images.

  19. Fast Ion extraction from the MedEBIS

    NASA Astrophysics Data System (ADS)

    Höltermann, H.; Becker, R.; Kleinod, M.; Müller, I.

    2004-01-01

    Cancer therapy synchrotrons profit from single turn injection in terms of size, costs and easy operation. The MEdically Dedicated EBIS (MEDEBIS), built in Frankfurt, will deliver short (~1.5 µs) and intense (~1.3 mA) pulses of highly charged light ions (C, N, O) to meet the requirements for therapy facilities. The MEDEBIS operates with an electron beam of 400 mA at 5 keV and a ratio of beam to drift tube of 1/20. Drift tube potentials up to 1.6 kV are switched in some 100 ns to deliver a 1.5 µs ion pulse at an axial field gradient of 6.5 kV/m. On extraction, all potentials applied to the drift tubes are set to a given primary potential to define the extraction gradient. During extraction the drift tubes are not held at constant voltage to avoid spreading out of the pulse due to the restoration of the full space charge depression at locations where ions have already been extracted. To locally distribute the action of the applied potentials the drift tubes are fully interpenetrating each other with tapered fingers. Combining these features result in a potential wall, which follows the extracted ion pulse and produces a compressed short ion pulse for single turn injection. In the future similar constructions could be considered for the RHIS EBIS device or proposed for LHC to provide the advantage with respect to lowest emittance and highest luminosity to the accelerators at BNL and CERN.

  20. Electronics for fast ion extraction from EBIS devices

    NASA Astrophysics Data System (ADS)

    Höltermann, H.; Becker, R.; Kleinod, M.; Müller, I.

    2004-05-01

    Future synchrotrons for cancer therapy could profit from single turn injection in terms of size, costs, and ease of operation [O. Kester, R. Becker, and M. Kleinod, Rev. Sci. Instrum. 67 (1996)]. Short (˜1.5 μs) and intense (˜1.3 mA) pulses of highly charged light ions (C6+, N7+, O8+) are a requirement for these future therapy facilities which can be provided by an EBIS ion source. Such a medically dedicated EBIS has an electron beam of 400 mA at 5 keV and needs an electron current density of 100 A/cm2 for a repetition rate of 10 Hz. To obtain a 1.5 μs ion pulse it is necessary to switch the drift tube potentials up to 1.6 kV (for a ratio of beam to drift tube of 1/20) in some 100 ns. To avoid spreading out of the pulse due to the restoration of the full space charge depression at locations where ions have already been extracted, the potentials applied to the drift tubes are changed with time. They will be adjusted for each drift tube according to the transit time of the ion pulse. Furthermore, the drift tubes are fully interpenetrating each other with tapered fingers in order to locally distribute the action of the applied potentials. This provides a potential wall, which is following the extracted ion pulse and results in a compressed short ion pulse for single turn injection into a synchrotron.

  1. 1. TEST STAND 1A ENVIRONS, SHOWING WEST SIDE OF TEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. TEST STAND 1-A ENVIRONS, SHOWING WEST SIDE OF TEST STAND 1-A, RP1 COMBINED FUEL STORAGE TANK FARM BELOW WATER TANKS ON HILLSIDE TO LEFT, AND TEST STAND 1-B IN DISTANCE AT RIGHT. Looking east. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  2. Bioinformatics training: selecting an appropriate learning content management system--an example from the European Bioinformatics Institute.

    PubMed

    Wright, Victoria Ann; Vaughan, Brendan W; Laurent, Thomas; Lopez, Rodrigo; Brooksbank, Cath; Schneider, Maria Victoria

    2010-11-01

    Today's molecular life scientists are well educated in the emerging experimental tools of their trade, but when it comes to training on the myriad of resources and tools for dealing with biological data, a less ideal situation emerges. Often bioinformatics users receive no formal training on how to make the most of the bioinformatics resources and tools available in the public domain. The European Bioinformatics Institute, which is part of the European Molecular Biology Laboratory (EMBL-EBI), holds the world's most comprehensive collection of molecular data, and training the research community to exploit this information is embedded in the EBI's mission. We have evaluated eLearning, in parallel with face-to-face courses, as a means of training users of our data resources and tools. We anticipate that eLearning will become an increasingly important vehicle for delivering training to our growing user base, so we have undertaken an extensive review of Learning Content Management Systems (LCMSs). Here, we describe the process that we used, which considered the requirements of trainees, trainers and systems administrators, as well as taking into account our organizational values and needs. This review describes the literature survey, user discussions and scripted platform testing that we performed to narrow down our choice of platform from 36 to a single platform. We hope that it will serve as guidance for others who are seeking to incorporate eLearning into their bioinformatics training programmes.

  3. 20. Building 202, detail of stand A, rocket test stand ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. Building 202, detail of stand A, rocket test stand in test cell. View looking southeast. - Rocket Engine Testing Facility, GRC Building No. 202, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH

  4. 31. HISTORIC VIEW OF TEST STAND NO. 1 AT PEENEMUENDE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. HISTORIC VIEW OF TEST STAND NO. 1 AT PEENEMUENDE A-4 ENGINE AND ROCKET PROPULSION TEST STAND. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  5. GENERAL VIEW OF SITE LOOKING SOUTHWEST. JUPITER 'HOP' STAND, FOREGROUND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    GENERAL VIEW OF SITE LOOKING SOUTHWEST. JUPITER 'HOP' STAND, FOREGROUND CENTER, REDSTONE TEST STAND FOREGROUND RIGHT, SATURN I C TEST STAND BACKGROUND LEFT. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  6. The Electron Beam Ion Source (EBIS)

    ScienceCinema

    Brookhaven Lab

    2017-12-09

    Brookhaven National Lab has successfully developed a new pre-injector system, called the Electron Beam Ion Source, for the Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory science programs. The first of several planned improvemen

  7. Standing Vs Supine; Does it Matter in Cough Stress Testing?

    PubMed

    Patnam, Radhika; Edenfield, Autumn L; Swift, Steven E

    The aim of this study was to compare the sensitivity of cough stress test in the standing versus supine position in the evaluation of incontinent females. We performed a prospective observational study of women with the chief complaint of urinary incontinence (UI) undergoing a provocative cough stress test (CST). Subjects underwent both a standing and a supine CST. Testing order was randomized via block randomization. Cough stress test was performed in a standard method via backfill of 200 mL or until the subject described strong urge. The subjects were asked to cough, and the physician documented urine leakage by direct observation. The gold standard for stress UI diagnosis was a positive CST in either position. Sixty subjects were enrolled, 38 (63%) tested positive on any CST, with 38 (63%) positive on standing compared with 29 (28%) positive on supine testing. Nine women (15%) had positive standing and negative supine testing. No subjects had negative standing with positive supine testing. There were no significant differences in positive tests between the 2 randomized groups (standing first and supine second vs. supine first and standing second). When compared with the gold standard of any positive provocative stress test, the supine CST has a sensitivity of 76%, whereas the standing CST has a sensitivity of 100%. The standing CST is more sensitive than the supine CST and should be performed in any patient with a complaint of UI and negative supine CST. The order of testing either supine or standing first does not affect the results.

  8. A-3 Test Stand work

    NASA Image and Video Library

    2011-07-29

    Work continues on the A-3 Test Stand at Stennis Space Center. The new stand will allow operators to test next-generation rocket engines at simulated altitudes up to 100,000 feet. The test stand is scheduled for completion and activation in 2013.

  9. A-3 Test Stand construction

    NASA Image and Video Library

    2010-10-01

    An 80,000-gallon liquid hydrogen tank is placed at the A-3 Test Stand construction site on Sept. 24, 2010. The tank will provide propellant for tests of next-generation rocket engines at the stand. It will be placed upright on top of the stand, helping to increase the overall height to 300 feet. Once completed, the A-3 Test Stand will enable operators to test rocket engines at simulated altitudes of up to 100,000 feet. The A-3 stand is the first large rocket engine test structure to be built at Stennis Space Center since the 1960s.

  10. A-3 Test Stand construction

    NASA Image and Video Library

    2010-09-24

    A 35,000-gallon liquid oxygen tank is placed at the A-3 Test Stand construction site on Sept. 24, 2010. The tank will provide propellant for tests of next-generation rocket engines at the stand. It will be placed upright on top of the stand, helping to increase the overall height to 300 feet. Once completed, the A-3 Test Stand will enable operators to test rocket engines at simulated altitudes of up to 100,000 feet. The A-3 stand is the first large rocket engine test structure to be built at Stennis Space Center since the 1960s.

  11. Photographic copy of site plan for proposed Test Stand "D" ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of site plan for proposed Test Stand "D" in 1958. The contemporary site plans of test stands "A," "B," and "C" are also visible, along with the interconnecting tunnel system. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering "Site Plan for Proposed Test Stand "D" - Edwards Test Station," drawing no. ESP/22-0, 14 November 1958 - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  12. A-3 Test Stand continues with test cell installation

    NASA Image and Video Library

    2010-07-20

    Employees at Stennis Space Center continue work on the A-3 Test Stand. As shown, a section of the test cell is lifted for installation on the stand's structural steel frame. Work on the A-3 Test Stand began in 2007. It is scheduled for activation in 2012.

  13. Production of low-Z ions in the Dresden superconducting electron ion beam source for medical particle therapy.

    PubMed

    Zschornack, G; Schwan, A; Ullmann, F; Grossmann, F; Ovsyannikov, V P; Ritter, E

    2012-02-01

    We report on experiments with a new superconducting electron beam ion source (EBIS-SC), the Dresden EBIS-SC, with the objective to meet the main requirements for their application in particle-therapy facilities. Synchrotrons as well as innovative accelerator concepts, such as high-gradient linacs which are driven by a large-current cyclotron (CYCLINACS) and direct drive RF linear accelerators may benefit from the advantages of EBISs in regard to their functional principle. First experimental studies of the production of low-Z ions such as H(+), H(2)(+), H(3)(+), C(4+), and C(6+) are presented. Particular attention is paid to the ion output, i.e., the number of ions per pulse and per second, respectively. Important beam parameters in this context are, among others, ion pulse shaping, pulse repetition rates, beam emittance, and ion energy spread.

  14. ChEMBL web services: streamlining access to drug discovery data and utilities

    PubMed Central

    Davies, Mark; Nowotka, Michał; Papadatos, George; Dedman, Nathan; Gaulton, Anna; Atkinson, Francis; Bellis, Louisa; Overington, John P.

    2015-01-01

    ChEMBL is now a well-established resource in the fields of drug discovery and medicinal chemistry research. The ChEMBL database curates and stores standardized bioactivity, molecule, target and drug data extracted from multiple sources, including the primary medicinal chemistry literature. Programmatic access to ChEMBL data has been improved by a recent update to the ChEMBL web services (version 2.0.x, https://www.ebi.ac.uk/chembl/api/data/docs), which exposes significantly more data from the underlying database and introduces new functionality. To complement the data-focused services, a utility service (version 1.0.x, https://www.ebi.ac.uk/chembl/api/utils/docs), which provides RESTful access to commonly used cheminformatics methods, has also been concurrently developed. The ChEMBL web services can be used together or independently to build applications and data processing workflows relevant to drug discovery and chemical biology. PMID:25883136

  15. Modification of electron beam ion source instability by longitudinal kinetic effects

    NASA Astrophysics Data System (ADS)

    Krafft, G. A.; Mark, J. W.-K.

    1982-07-01

    The electron beam ion source (EBIS) was proposed and subsequently realized by Donets. Further development has been done by the Orsay group and by the Berkeley group. Much theoretical work has been done on EBIS and, in particular, Litwin, Vella, and Sessler find that an electrostatic mode of the electron beam-ion system is unstable using a fluid calculation. The present work indicates that the inclusion of a longitudinal velocity spread in the electron beam decreases the instability growth rate, but their conclusions are not significantly modified. Numerically it is shown that substantial linear instability remains, even when sizeable longitudinal velocity spread is included. The principal result of the work is fig. 1; it gives the complex frequency of the mode as a function of σ/ υ0 z, σ being the spread and υ0 z being the average electron axial velocity.

  16. A-3 Test Stand

    NASA Image and Video Library

    2012-06-08

    A tethered Stennis Space Center employee climbs an A-3 Test Stand ladder June 8, 2012, against the backdrop of the A-2 and B-1/B-2 stands. The new A-3 Test Stand will enable simulated high-altitude testing of next-generation rocket engines.

  17. A-3 Test Stand

    NASA Image and Video Library

    2012-06-08

    A tethered Stennis Space Center employee climbs an A-3 Test Stand ladded June 8, 2012, against the backdrop of the A-2 and B-1/B-2 stands. The new A-3 Test Stand will enable simulated high-altitude testing of next-generation rocket engines.

  18. 13. Photographic copy of site plan displaying Test Stand 'C' ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. Photographic copy of site plan displaying Test Stand 'C' (4217/E-18), Test Stand 'D' (4223/E-24), and Control and Recording Center (4221/E-22) with ancillary structures, and connecting roads and services. California Institute of Technology, Jet Propulsion Laboratory, Facilities Engineering and Construction Office 'Repairs to Test Stand 'C,' Edwards Test Station, Legend & Site Plan M-1,' drawing no. ESP/115, August 14, 1987. - Jet Propulsion Laboratory Edwards Facility, Test Stand C, Edwards Air Force Base, Boron, Kern County, CA

  19. Credit WCT. Photographic copy of photograph, view of Test Stand ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit WCT. Photographic copy of photograph, view of Test Stand "D" from Test Stand "A" while a rocket engine test is in progress. Cloud of steam is from partly from water created by propellant reaction and from water sprayed by flame bucket into engine exhaust for cooling purposes. A portion of Test Stand "C" is visible at the far right. (JPL negative no. 384-2082-B, 23 October 1959) - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  20. Credit BG. View looking northeast at southwestern side of Test ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit BG. View looking northeast at southwestern side of Test Stand "D" complex. Test Stand "D" workshop (Building 4222/E-23) is at left; shed to its immediate right is an entrance to underground tunnel system which interconnects all test stands. To the right of Test Stand "D" tower are four Clayton water-tube flash boilers once used in the Steam Generator Plant 4280/E-81 to power the vacuum ejector system at "D" and "C" stands. A corner of 4280/E-81 appears behind the boilers. Boilers were removed as part of stand dismantling program. The Dv (vertical vacuum) Test Cell is located in the Test Stand "D" tower, behind the sunscreen on the west side. The top of the tower contains a hoist for lifting or lowering rocket engines into the Dv Cell. Other equipment mounted in the tower is part of the steam-driven vacuum ejector system - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  1. 1. Photographic copy of original engineering drawing for Test Stand ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Photographic copy of original engineering drawing for Test Stand 'C.' California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering 'New Test Stand Plan -- Edwards Test Station' drawing no. E18/2-3, 18 January 1957. - Jet Propulsion Laboratory Edwards Facility, Test Stand C, Edwards Air Force Base, Boron, Kern County, CA

  2. View looking west at Test Stand 'A' complex in morning ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View looking west at Test Stand 'A' complex in morning sun. View shows Monitor Building 4203/E-4 at left, barrier (Building 4216/E-17) to right of 4203/E-4, and Test Stand 'A' tower. Attached structure to lower left of tower is Test Stand 'A' machine room which contained refrigeration equipment. Building in right background with Test Stand 'A' tower shadow on it is Assembly Building 4288/E-89, built in 1984. Row of ground-mounted brackets in foreground was used to carry electrical cable and/or fuel lines. - Jet Propulsion Laboratory Edwards Facility, Test Stand A, Edwards Air Force Base, Boron, Kern County, CA

  3. The process of adapting a universal dating abuse prevention program to adolescents exposed to domestic violence.

    PubMed

    Foshee, Vangie A; Dixon, Kimberly S; Ennett, Susan T; Moracco, Kathryn E; Bowling, J Michael; Chang, Ling-Yin; Moss, Jennifer L

    2015-07-01

    Adolescents exposed to domestic violence are at increased risk of dating abuse, yet no evaluated dating abuse prevention programs have been designed specifically for this high-risk population. This article describes the process of adapting Families for Safe Dates (FSD), an evidenced-based universal dating abuse prevention program, to this high-risk population, including conducting 12 focus groups and 107 interviews with the target audience. FSD includes six booklets of dating abuse prevention information, and activities for parents and adolescents to do together at home. We adapted FSD for mothers who were victims of domestic violence, but who no longer lived with the abuser, to do with their adolescents who had been exposed to the violence. Through the adaptation process, we learned that families liked the program structure and valued being offered the program and that some of our initial assumptions about this population were incorrect. We identified practices and beliefs of mother victims and attributes of these adolescents that might increase their risk of dating abuse that we had not previously considered. In addition, we learned that some of the content of the original program generated negative family interactions for some. The findings demonstrate the utility of using a careful process to adapt evidence-based interventions (EBIs) to cultural sub-groups, particularly the importance of obtaining feedback on the program from the target audience. Others can follow this process to adapt EBIs to groups other than the ones for which the original EBI was designed. © The Author(s) 2014.

  4. Synthesis of Carbon Foam from Waste Artificial Marble Powder and Carboxymethyl Cellulose via Electron Beam Irradiation and Its Characterization

    PubMed Central

    Kim, Hong Gun; Kim, Yong Sun; Kwac, Lee Ku; Chae, Su-Hyeong; Shin, Hye Kyoung

    2018-01-01

    Carbon foams were prepared by carbonization of carboxymethyl cellulose (CMC)/waste artificial marble powder (WAMP) composites obtained via electron beam irradiation (EBI); these composites were prepared by mixing eco-friendly CMC with WAMP as the fillers for improved their poor mechanical strength. Gel fractions of the CMC/WAMP composites obtained at various EBI doses were investigated, and it was found that the CMC/WAMP composites obtained at an EBI dose of 80 kGy showed the highest gel fraction (95%); hence, the composite prepared at this dose was selected for preparing the carbon foam. The thermogravimetric analysis of the CMC/WAMP composites obtained at 80 kGy; showed that the addition of WAMP increased the thermal stability and carbon residues of the CMC/WAMP composites at 900 °C. SEM images showed that the cell walls of the CMC/WAMP carbon foams were thicker more than those of the CMC carbon foam. In addition, energy dispersive X-ray spectroscopy showed that the CMC/WAMP carbon foams contained small amounts of aluminum, derived from WAMP. The results confirmed that the increased WAMP content and hence increased aluminum content improved the thermal conductivity of the composites and their corresponding carbon foams. Moreover, the addition of WAMP increased the compressive strength of CMC/WAMP composites and hence the strength of their corresponding carbon foams. In conclusion, this synthesis method is encouraging, as it produces carbon foams of pore structure with good mechanical properties and thermal conductivity. PMID:29565300

  5. Transportability of an Evidence-Based Early Childhood Intervention in a Low-Income African Country: Results of a Cluster Randomized Controlled Study.

    PubMed

    Huang, Keng-Yen; Nakigudde, Janet; Rhule, Dana; Gumikiriza-Onoria, Joy Louise; Abura, Gloria; Kolawole, Bukky; Ndyanabangi, Sheila; Kim, Sharon; Seidman, Edward; Ogedegbe, Gbenga; Brotman, Laurie Miller

    2017-11-01

    Children in Sub-Saharan Africa (SSA) are burdened by significant unmet mental health needs. Despite the successes of numerous school-based interventions for promoting child mental health, most evidence-based interventions (EBIs) are not available in SSA. This study investigated the implementation quality and effectiveness of one component of an EBI from a developed country (USA) in a SSA country (Uganda). The EBI component, Professional Development, was provided by trained Ugandan mental health professionals to Ugandan primary school teachers. It included large-group experiential training and small-group coaching to introduce and support a range of evidence-based practices (EBPs) to create nurturing and predictable classroom experiences. The study was guided by the Consolidated Framework for Implementation Research, the Teacher Training Implementation Model, and the RE-AIM evaluation framework. Effectiveness outcomes were studied using a cluster randomized design, in which 10 schools were randomized to intervention and wait-list control conditions. A total of 79 early childhood teachers participated. Teacher knowledge and the use of EBPs were assessed at baseline and immediately post-intervention (4-5 months later). A sample of 154 parents was randomly selected to report on child behavior at baseline and post-intervention. Linear mixed effect modeling was applied to examine effectiveness outcomes. Findings support the feasibility of training Ugandan mental health professionals to provide Professional Development for Ugandan teachers. Professional Development was delivered with high levels of fidelity and resulted in improved teacher EBP knowledge and the use of EBPs in the classroom, and child social competence.

  6. Protective immune response against Toxoplasma gondii elicited by a novel yeast-based vaccine with microneme protein 16.

    PubMed

    Wang, Long-Jiang; Xiao, Ting; Xu, Chao; Li, Jin; Liu, Gong-Zhen; Yin, Kun; Cui, Yong; Wei, Qing-Kuan; Huang, Bing-Cheng; Sun, Hui

    2018-06-22

    Toxoplasma gondii is an obligate intracellular protozoan that can invade all eukaryotic cells and infect all warm-blood animals, causing the important zoonosis toxoplasmosis. Invasion of host cells is the key step necessary for T. gondii to complete its life cycle and microneme proteins play an important role in attachment and invasion of host cells. Microneme protein 16 (TgMIC16) is a new protective protein in T. gondii and belongs to transmembrane microneme proteins (TM-MIC). The TM-MICs are released onto the parasite's surface as complexes capable of interacting with host cell receptors. In the present study, we expressed the TgMIC16 protein on the surface of Saccharomyce cerevisiae (pCTCON2-TgMIC16/EBY100) and evaluated it as a potential vaccine for BALB/c mice against challenge infection with the RH strain of T. gondii. We immunized BALB/c mice both orally and intraperitoneally. After three immunizations, the immune response was evaluated by measuring antibody levels, lymphocyte proliferative responses, percentages of CD4 + and CD8 + T lymphocytes, cytokine production, and the survival times of challenged mice. The results showed that the pCTCON2-TgMIC16/EBY100 vaccine stimulated humoral and cellular immune responses. In addition, mice immunized with the pCTCON2-TgMIC16/EBY100 vaccine showed increased survival times compared with non-immunized controls. In summary, TgMIC16 displayed on the cell surface of S. cerevisiae could be used as potential vaccine against toxoplasmosis. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. 25. "TEST STAND 1A UTILIZED TO TEST THE ATLAS ICBM", ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. "TEST STAND 1-A UTILIZED TO TEST THE ATLAS ICBM", CROPPED OUT: "DIRECTORATE OF MISSILE CAPTIVE TEST, EDWARDS AFB." Photo no. 11,371 57; G-AFFTC 15 OCT 57. Looking southwest from below the stand. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  8. n/a

    NASA Image and Video Library

    1963-01-15

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. The F-1 Engine test stand was built north of the massive S-IC test stand. The F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability is provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This aerial photograph, taken January 15, 1963, gives a close overall view of the newly developed test complex. Depicted in the forefront center is the S-IC test stand with towers prominent, the Block House is seen in the center just above the S-IC test stand, and the large hole to the left, located midway between the two is the F-1 test stand site.

  9. Around Marshall

    NASA Image and Video Library

    1963-01-15

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. The F-1 Engine test stand was built north of the massive S-IC test stand. The F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability is provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. Looking North, this aerial taken January 15, 1963, gives a closer view of the deep hole for the F-1 test stand site in the forefront. The S-IC test stand with towers prominent is to the right of center, and the Block House is seen left of center.

  10. A-1 Test Stand modifications

    NASA Image and Video Library

    2011-09-14

    Team members check the progress of a liquid nitrogen cold shock test on the A-1 Test Stand at Stennis Space Center on Sept. 15. The cold shock test is used to confirm the test stand's support system can withstand test conditions, when super-cold rocket engine propellant is piped. The A-1 Test Stand is preparing to conduct tests on the powerpack component of the J-2X rocket engine, beginning in early 2012.

  11. 1. TEST AREA 1115, SOUTH PART OF SUPPORT COMPLEX, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. TEST AREA 1-115, SOUTH PART OF SUPPORT COMPLEX, LOOKING TO EAST FROM ABOVE BUILDING 8655, THE FUEL STORAGE TANK FARM, IN FOREGROUND SHADOW. AT THE RIGHT IS BUILDING 8660, ELECTRICAL SUBSTATION; TO ITS LEFT IS BUILDING 8663, THE HELIUM COMPRESSION PLANT. THE LIGHT TONED STRUCTURE IN THE MIDDLE DISTANCE, CENTER, IS THE MACHINE SHOP FOR TEST STAND 1-3. IN THE FAR DISTANCE IS TEST STAND 1-A, WITH THE WHITE SPHERICAL TANKS, AND TEST STAND 2-A TO ITS RIGHT. ALONG THE HORIZON FROM FAR LEFT ARE TEST STAND 1-D, TEST STAND 1-C, WATER TANKS ABOVE TEST AREA 1-125, AND TEST STAND 1-B IN TEST AREA 1-120. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA

  12. n/a

    NASA Image and Video Library

    1963-01-15

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. The F-1 Engine test stand was built north of the massive S-IC test stand. The F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability is provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This aerial photograph, taken January 15, 1963 gives an overall view of the construction progress of the newly developed test complex. The large white building located in the center is the Block House. Just below and to the right of it is the S-IC test stand. The large hole to the left of the S-IC stand is the F-1 test stand site.

  13. Busy test week

    NASA Image and Video Library

    2012-11-08

    NASA recorded a historic week Nov. 5-9, conducting tests on all three stands in the E Test Complex at John C. Stennis Space Center. Inset images show the types of tests conducted on the E-1 Test Stand (right), the E-2 Test Stand (left) and the E-3 Test Stand (center). The E-1 photo is from an early October test and is provided courtesy of Blue Origin. Other photos are from tests conducted the week of Nov. 5.

  14. A-2 Test Stand modification work

    NASA Image and Video Library

    2010-10-27

    John C. Stennis Space Center employees install a new master interface tool on the A-2 Test Stand on Oct. 27, 2010. Until July 2009, the stand had been used for testing space shuttle main engines. With that test series complete, employees are preparing the stand for testing the next-generation J-2X rocket engine being developed. Testing of the new engine is scheduled to begin in 2011.

  15. 38. HISTORIC CLOSER VIEW LOOKING WEST OF THE TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. HISTORIC CLOSER VIEW LOOKING WEST OF THE TEST STAND AND ROCKET DURING TEST FIRING NUMBER 10. NOTE THE NUMBER ALONG THE TOP RAIL OF THE STAND JUST TO THE RIGHT OF THE ROCKET, THIS NUMBER INDICATES WHAT NUMBER TEST IS BEING CONDUCTED. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  16. 49 CFR 210.33 - Operation standards (switcher locomotives, load cell test stands, car coupling operations, and...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... cell test stands, car coupling operations, and retarders). 210.33 Section 210.33 Transportation Other... (switcher locomotives, load cell test stands, car coupling operations, and retarders). (a) Measurement on receiving property of the noise emission levels from switcher locomotives, load cell test stands, car...

  17. 49 CFR 210.33 - Operation standards (switcher locomotives, load cell test stands, car coupling operations, and...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... cell test stands, car coupling operations, and retarders). 210.33 Section 210.33 Transportation Other... (switcher locomotives, load cell test stands, car coupling operations, and retarders). (a) Measurement on receiving property of the noise emission levels from switcher locomotives, load cell test stands, car...

  18. 49 CFR 210.33 - Operation standards (switcher locomotives, load cell test stands, car coupling operations, and...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... cell test stands, car coupling operations, and retarders). 210.33 Section 210.33 Transportation Other... (switcher locomotives, load cell test stands, car coupling operations, and retarders). (a) Measurement on receiving property of the noise emission levels from switcher locomotives, load cell test stands, car...

  19. 49 CFR 210.33 - Operation standards (switcher locomotives, load cell test stands, car coupling operations, and...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... cell test stands, car coupling operations, and retarders). 210.33 Section 210.33 Transportation Other... (switcher locomotives, load cell test stands, car coupling operations, and retarders). (a) Measurement on receiving property of the noise emission levels from switcher locomotives, load cell test stands, car...

  20. 49 CFR 210.33 - Operation standards (switcher locomotives, load cell test stands, car coupling operations, and...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... cell test stands, car coupling operations, and retarders). 210.33 Section 210.33 Transportation Other... (switcher locomotives, load cell test stands, car coupling operations, and retarders). (a) Measurement on receiving property of the noise emission levels from switcher locomotives, load cell test stands, car...

  1. A-1 Test Stand work

    NASA Technical Reports Server (NTRS)

    2010-01-01

    Employees at NASA's John C. Stennis Space Center work to maneuver a structural steam beam into place on the A-1 Test Stand on Jan. 13. The beam was one of several needed to form the thrust takeout structure that will support a new thrust measurement system being installed on the stand for future rocket engine testing. Once lifted onto the stand, the beams had to be hoisted into place through the center of the test stand, with only two inches of clearance on each side. The new thrust measurement system represents a state-of-the-art upgrade from the equipment installed more than 40 years ago when the test stand was first constructed.

  2. Historic tests

    NASA Image and Video Library

    2012-08-16

    Two large-engine tests were conducted simultaneously for the first time at Stennis Space Center on Aug. 16. A plume on the left indicates a test on the facility's E-1 Test Stand. On the right, a finger of fire indicates a test under way on the A-1 Test Stand. In another first, both tests were conducted by female engineers. The image was taken from atop the facility's A-2 Test Stand, offering a panoramic view that includes the new A-3 Test Stand under construction to the left.

  3. 24. SATURN V Fl ENGINE TEST FIRING ON TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. SATURN V F-l ENGINE TEST FIRING ON TEST STAND 1A. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  4. Stand for testing the electrical race car engine

    NASA Astrophysics Data System (ADS)

    Baier, M.; Franiasz, J.; Mierzwa, P.; Wylenzek, D.

    2015-11-01

    An engine test stand created especially for research of electrical race car is described in the paper. The car is an aim of Silesian Greenpower project whose participants build and test electrical vehicles to take part in international races in Great Britain. The engine test stand is used to test and measure the characteristics of vehicles and their engines. It has been designed particularly to test the electric cars engineered by students of Silesian Greenpower project. The article contains a description how the test stand works and shows its versatility in many areas. The paper presents both construction of the test stand, control system and sample results of conducted research. The engine test stand was designed and modified using PLM Siemens NX 8.5. The construction of the test stand is highly modular, which means it can be used both for testing the vehicle itself or for tests without the vehicle. The test stand has its own wheel, motor, powertrain and braking system with second engine. Such solution enables verifying various concepts without changing the construction of the vehicle. The control system and measurement system are realized by enabling National Instruments product myRIO (RIO - Reconfigurable Input/Output). This controller in combination with powerful LabVIEW environment performs as an advanced tool to control torque and speed simultaneously. It is crucial as far as the test stand is equipped in two motors - the one being tested and the braking one. The feedback loop is realized by an optical encoder cooperating with the rotor mounted on the wheel. The results of tests are shown live on the screen both as a chart and as single values. After performing several tests there is a report generated. The engine test stand is widely used during process of the Silesian Greenpower vehicle design. Its versatility enables powertrain testing, wheels and tires tests, thermal analysis and more.

  5. Advantages and disadvantages for receiving Internet-based HIV/AIDS interventions at home or at community-based organizations.

    PubMed

    Green, Shana M; Lockhart, Elizabeth; Marhefka, Stephanie L

    2015-01-01

    Within recent years, public health interventions have become technology based to reflect the digital age we currently live in and appeal to the public in innovative and novel ways. The Internet breaks down boundaries distance imposes and increases our ability to reach and connect with people. Internet-based interventions have the potential to expand access to effective behavioral interventions (EBIs). The US National HIV/AIDS Strategy states that people living with HIV should have access to EBIs such as healthy relationships (HR) to help them develop safe sex and disclosure skills. However, access to HR is limited across the country, especially for people in remote or rural areas. Internet-based healthy relationships video groups (HR-VG) delivered at home or community-based organizations (CBOs) can possibly expand access. This study assesses the preferences of women living with HIV (WLH) for participation in HR-VG among 21 WLH who participated in a randomized control trial (RCT) testing HR-VG and completed open-ended semi-structured telephone interviews. Transcripts were thematically analyzed to determine advantages and disadvantages of home or CBO delivery of HR-VG. Themes relating to convenience, technology access, privacy, distractions, HIV serostatus disclosure, and social opportunities were identified as advantages or disadvantages to participating in HR-VG at each location. Overall, privacy was the most salient concern of accessing HR-VG at home or at a CBO. Considering the concerns expressed by WLH, further studies are needed to assess how an Internet-based intervention delivered at home for WLH can maintain privacy while being cost effective.

  6. View east northeast at Test Stand 'A' complex from road, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View east northeast at Test Stand 'A' complex from road, showing Test Stand 'C' test tower in left background (Building 4217/E-18). Curved I-beam labeled '3-ton' is for small traveling hoist. Fuel tanks, propellant lines, and control panels have been removed from tower. - Jet Propulsion Laboratory Edwards Facility, Test Stand A, Edwards Air Force Base, Boron, Kern County, CA

  7. 1. VIEW NORTHEAST, LEFT TO RIGHT COLD CALIBRATION TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VIEW NORTHEAST, LEFT TO RIGHT COLD CALIBRATION TEST STAND COLD CALIBRATION BLOCKHOUSE IN FOREGROUND. - Marshall Space Flight Center, East Test Area, Cold Calibration Test Stand, Huntsville, Madison County, AL

  8. A-3 Test Stand work

    NASA Image and Video Library

    2011-07-29

    Stennis Space Center employees have installed liquid oxygen and liquid hydrogen tanks atop the A-3 Test Stand, raising the structure to its full 300-foot height. The stand is being built to test next-generation rocket engines that could carry humans beyond low-Earth orbit into deep space. The A-3 Test Stand is scheduled for completion and activation in 2013.

  9. 40 CFR 201.27 - Procedures for: (1) Determining applicability of the locomotive load cell test stand standard and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... applicability of the locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving property; (2) measurement of locomotive load cell test stands more than 120 meters... locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving...

  10. 40 CFR 201.27 - Procedures for: (1) Determining applicability of the locomotive load cell test stand standard and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... applicability of the locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving property; (2) measurement of locomotive load cell test stands more than 120 meters... locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving...

  11. 40 CFR 201.27 - Procedures for: (1) Determining applicability of the locomotive load cell test stand standard and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... applicability of the locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving property; (2) measurement of locomotive load cell test stands more than 120 meters... locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving...

  12. 40 CFR 201.27 - Procedures for: (1) Determining applicability of the locomotive load cell test stand standard and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... applicability of the locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving property; (2) measurement of locomotive load cell test stands more than 120 meters... locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving...

  13. 40 CFR 201.27 - Procedures for: (1) Determining applicability of the locomotive load cell test stand standard and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... applicability of the locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving property; (2) measurement of locomotive load cell test stands more than 120 meters... locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving...

  14. Photographic copy of photograph, aerial view looking north and showing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of photograph, aerial view looking north and showing Test Stand 'A' (at bottom), Test Stand 'B' (upper right), and a portion of Test Stand 'C' (top of view). Compare HAER CA-163-1 and 2 and note addition of liquid nitrogen storage tank (Building 4262/E-63) to west of Test Stand 'C' as well as various ancillary facilities located behind earth barriers near Test Stand 'C.' (JPL negative no. 384-3006-A, 12 December 1961) - Jet Propulsion Laboratory Edwards Facility, Edwards Air Force Base, Boron, Kern County, CA

  15. Around Marshall

    NASA Image and Video Library

    1962-07-03

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the construction of the F-1 test stand as of July 3, 1963. All four of its tower legs are well underway.

  16. Around Marshall

    NASA Image and Video Library

    1963-09-05

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the construction of the F-1 test stand as of September 5, 1963.

  17. n/a

    NASA Image and Video Library

    1962-10-26

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the S-IC test stand, related facilities were built during this time. Built to the north of the massive S-IC test stand, was the F-1 Engine test stand. The F-1 test stand, a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, was designed to assist in the development of the F-1 Engine. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo, taken October 26, 1962, depicts the excavation process of the single engine F-1 stand.

  18. Around Marshall

    NASA Image and Video Library

    1963-09-30

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the construction of the F-1 test stand as of September 30, 1963.

  19. Around Marshall

    NASA Image and Video Library

    1963-06-24

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the construction of the F-1 test stand as of June 24, 1963. Two if its four tower legs are underway.

  20. n/a

    NASA Image and Video Library

    1962-11-15

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the S-IC test stand, related facilities were built during this time. Built to the north of the massive S-IC test stand, was the F-1 Engine test stand. The F-1 test stand, a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, was designed to assist in the development of the F-1 Engine. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo, taken November 15, 1962, depicts the excavation process of the single engine F-1 stand site.

  1. Around Marshall

    NASA Image and Video Library

    1963-10-22

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Northeast of the massive S-IC test stand, the F-1 Engine test stand was built. The F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the fuel tanks that housed kerosene and just beyond those is the F-1 test stand.

  2. 23. "A CAPTIVE ATLAS MISSILE EXPLODED DURING THE TEST ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. "A CAPTIVE ATLAS MISSILE EXPLODED DURING THE TEST ON TEST STAND 1-A, 27 MARCH 1959, PUTTING THAT TEST STAND OUT-OF-COMMISSION. STAND WAS NOT REPAIRED FOR THE ATLAS PROGRAM BUT TRANSFERRED TO ROCKETDYNE AND MODIFIED FOR THE F-l ENGINE PROGRAM." - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  3. 8. TEST STAND 15, INVERTED ENGINE FIRING TEST, CIRCA 1963. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. TEST STAND 1-5, INVERTED ENGINE FIRING TEST, CIRCA 1963. Original is a color print. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-5, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  4. A-3 Test Stand work continues

    NASA Image and Video Library

    2011-04-22

    Stennis Space Center employees continue work on the A-3 Test Stand test cell. The stand is being built to test next-generation rocket engines that could carry humans beyond low-Earth orbit into deep space.

  5. 9. COLD CALIBRATION TEST STAND (H1) FROM LEFT TO RIGHT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. COLD CALIBRATION TEST STAND (H-1) FROM LEFT TO RIGHT - WORK BENCH, CONTROL PANEL, CHEMICAL TANK. - Marshall Space Flight Center, East Test Area, Cold Calibration Test Stand, Huntsville, Madison County, AL

  6. 5. EAST SIDE, TEST STAND AND ITS SUPERSTRUCTURE. Edwards ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. EAST SIDE, TEST STAND AND ITS SUPERSTRUCTURE. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  7. PERSPECTIVE VIEW LOOKING NORTHEAST AT THE TEST STAND, NOTE THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PERSPECTIVE VIEW LOOKING NORTHEAST AT THE TEST STAND, NOTE THE SERVICE AND SUPPORT BUILDINGS TO THE LEFT AND RIGHT OF THE TEST STAND. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL

  8. Impact of pretransplant rifaximin therapy on early post-liver transplant infections.

    PubMed

    Esfeh, Jamak Modaresi; Hanouneh, Ibrahim A; Koval, Christine E; Kovacs, Christopher; Dalal, Deepan S; Ansari-Gilani, Kianoush; Confer, Bradley D; Eghtesad, Bijan; Zein, Nizar N; Menon, K V Narayanan

    2014-05-01

    Bacterial and fungal infections are major causes of morbidity and mortality after liver transplantation (LT). The role of intestinal decontamination in the prevention of post-LT infections is controversial. Rifaximin is widely used for the treatment of hepatic encephalopathy. The effect of rifaximin on post-LT infections is unknown. The aim of our study was to determine the effect of rifaximin therapy in the pretransplant period on early bacterial infections (EBIs) and fungal infections within the first 30 days after LT. All adult patients who underwent LT at our institution (January 2009 to July 2011) were included in this retrospective cohort study. Patients receiving antibiotics other than pretransplant protocol antibiotics were excluded. Patients were stratified into 2 groups based on the presence or absence of rifaximin therapy for at least 2 days before LT. Infections were defined by the isolation of any bacterial or fungal organisms within 30 days of LT. Multivariate regression analysis, Student t tests, and Pearson's chi-square tests were used to compare the 2 groups. Two hundred sixty-eight patients were included, and 71 of these patients (26.5%) were on rifaximin at the time of LT. The 2 groups were comparable with respect to age, sex, race, and Model for End-Stage Liver Disease score. There were no significant differences in the rates of EBIs (30% for the non-rifaximin group and 25% for the rifaximin group, P = 0.48) or fungal infections between the 2 groups. There was no increase in antimicrobial resistance among the infecting organisms. There was no difference in survival between the rifaximin and non-rifaximin groups (98% versus 97%, P = 0.36). In conclusion, the use of rifaximin in the pre-LT period was not associated with an increased risk of bacterial or fungal infections in the early post-LT period. © 2014 American Association for the Study of Liver Diseases.

  9. CLOSEUP VIEW LOOKING SOUTH AT THE SATURN I TEST STAND, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    CLOSE-UP VIEW LOOKING SOUTH AT THE SATURN I TEST STAND, NOTE THE INTERPRETIVE SIGN EXPLAINING THE HISTORIC NATURE OF THE SATURN I TEST STAND. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL

  10. 43. HISTORIC VIEW LOOKING SOUTHWEST AT THE TEST STAND WITH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. HISTORIC VIEW LOOKING SOUTHWEST AT THE TEST STAND WITH A REDSTONE ROCKET BEING FUELED AND PREPARED FOR TESTING. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  11. 3. "TEST STAND NO. 13, EXCAVATION PLAN & SECTIONS." Specifications ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. "TEST STAND NO. 1-3, EXCAVATION PLAN & SECTIONS." Specifications No. ENG 04-353-50-10; Drawing No. 60-0906; no sheet number within title block; D.O. SERIES 1109/10. Stamped: AS BUILT. No revisions or revision dates. Last work date on this drawing "Checked by EAG, 1/31/49." Though this drawing is specific to Test Stand 1-3, it also illustrates the general methods used for excavation design and retaining wall construction at Test Stand 1-5. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  12. 1. Credit PSR. This view displays the north and west ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Credit PSR. This view displays the north and west facades of Test Stand "G" (Vibration Facility) as seen when looking east southeast (110°). Test Stand "G" no longer houses the vibrator; it now houses an autoclave due to the changing nature of the testing work. The Vibration Facility was Test Stand "G"'s historic function. Test Stand "E" is at the far right. The Vibration Facility subjected motor and engine assemblies to various vibration patterns in order to simulate flight conditions and evaluate the durability of engine and motor designs. - Jet Propulsion Laboratory Edwards Facility, Test Stand G, Edwards Air Force Base, Boron, Kern County, CA

  13. Combination of electron beam irradiation and thermal treatment to enhance the shelf-life of traditional Indian fermented food (Idli)

    NASA Astrophysics Data System (ADS)

    Mulmule, Manoj D.; Shimmy, Shankar M.; Bambole, Vaishali; Jamdar, Sahayog N.; Rawat, K. P.; Sarma, K. S. S.

    2017-02-01

    Idli, a steam-cooked breakfast food item consumed in India, is famous as a staple food for its spongy texture and unique fermented taste. Idli preparation is a time consuming process; although instant Idli pre-mixes as powder or batter are available in the market, they do not have the distinctive taste and aroma similar to the Idli prepared at home. Hence ready-to-eat (RTE) form of this food is in demand. Therefore, an attempt was made to prepare RTE Idli bearing similar taste as home-cooked Idli with an extended shelf-life of up to two months at an ambient temperature using Electron Beam Irradiation (EBI) at dosages 2.5 kGy, 5 kGy and 7.5 kGy and combination processing comprised of EBI dosage at 2.5 kGy and thermal treatment (80 °C for 20 min). The treated Idli's were microbiologically and sensorially evaluated at storage periods of zero day, 14 days, 30 days and 60 days. Idli's irradiated at 7.5 kGy and subjected to combination processing at 2.5 kGy and thermal treatment were shelf-stable for 60 days. 2.5 kGy and 5 kGy radiation dosages alone were not sufficient to preserve Idli samples for more than 14 days. Undesirable change in sensory properties of Idli was observed at an EBI dosage of 7.5 kGy. Sensory properties of combination processed Idli's were found to undergo minor change over the storage period. The present work suggests that lowest radiation dosage in combination with thermal treatment could be useful to achieve the extended shelf-life without considerably impairing the organoleptic quality of Ready-to-Eat Idli.

  14. Electron string phenomenon: physics and use

    NASA Astrophysics Data System (ADS)

    Donets, Evgeny D.

    2004-01-01

    Electron string phenomenon arises as a result of phase transition of a state of multiply reflected electron beam to this new discovered state of one component electron plasma and can be easily observed in the reflex mode of EBIS operation. The transition goes via a strong instability, which causes considerable electron energy spread, which in its turn suppresses the instability. Electron string state is a stationary state of hot pure electron plasma, which is heated by injected electron beam and cooled because of electron loses. Electron string is quiet in broad regions of experimental parameters, so that it is used for confinement and ionization of positive ions by electron impact to highly charge states similar to electron beams in EBIS. Application of electron strings instead of electron beams for ion production allows to save about 99% of electric power of electron beam and simultaneously to improve reliability of an ion source considerably. The JINR EBIS `Krion-2' in the string mode of operation is used for production of N7+, Ar16+ and Fe24+ ion beams and their acceleration to relativistic energies on the facility of the JINR super conducting one turn injection synchrotron `Nuklotron'. The tubular electron string possibly can exist and it is under study now theoretically and experiments are prepared now. Estimations show that a Tubular Electron String Ion Source (TESIS) could have up to three orders of magnitude higher ion output then a Linear one (LESIS). In frames of nuclear astrophysics electron strings can be used for research of fusion nuclear reactions at low energies in conditions when both beam and target nuclei do not carry orbital electrons. The project NARITA — Nuclear Astrophysics Researches in an Ion Trap Apparatus is proposed. Polarization effects also can be studied.

  15. Identification of OBO nonalignments and its implications for OBO enrichment.

    PubMed

    Bada, Michael; Hunter, Lawrence

    2008-06-15

    Existing projects that focus on the semiautomatic addition of links between existing terms in the Open Biomedical Ontologies can take advantage of reasoners that can make new inferences between terms that are based on the added formal definitions and that reflect nonalignments between the linked terms. However, these projects require that these definitions be necessary and sufficient, a strong requirement that often does not hold. If such definitions cannot be added, the reasoners cannot point to the nonalignments through the suggestion of new inferences. We describe a methodology by which we have identified over 1900 instances of nonredundant nonalignments between terms from the Gene Ontology (GO) biological process (BP), cellular component (CC) and molecular function (MF) ontologies, Chemical Entities of Biological Interest (ChEBI) and the Cell Type Ontology (CL). Many of the 39.8% of these nonalignments whose object terms are more atomic than the subject terms are not currently examined in other ontology-enrichment projects due to the fact that the necessary and sufficient conditions required for the inferences are not currently examined. Analysis of the ratios of nonalignments to assertions from which the nonalignments were identified suggests that BP-MF, BP-BP, BP-CL and CC-CC terms are relatively well-aligned, while ChEBI-MF, BP-ChEBI and CC-MF terms are relatively not aligned well. We propose four ways to resolve an identified nonalignment and recommend an analogous implementation of our methodology in ontology-enrichment tools to identify types of nonalignments that are currently not detected. The nonalignments discussed in this article may be viewed at http://compbio.uchsc.edu/Hunter_lab/Bada/nonalignments_2008_03_06.html. Code for the generation of these nonalignments is available upon request. mike.bada@uchsc.edu.

  16. Large-scale generic test stand for testing of multiple configurations of air filters utilizing a range of particle size distributions

    NASA Astrophysics Data System (ADS)

    Giffin, Paxton K.; Parsons, Michael S.; Unz, Ronald J.; Waggoner, Charles A.

    2012-05-01

    The Institute for Clean Energy Technology (ICET) at Mississippi State University has developed a test stand capable of lifecycle testing of high efficiency particulate air filters and other filters specified in American Society of Mechanical Engineers Code on Nuclear Air and Gas Treatment (AG-1) filters. The test stand is currently equipped to test AG-1 Section FK radial flow filters, and expansion is currently underway to increase testing capabilities for other types of AG-1 filters. The test stand is capable of producing differential pressures of 12.45 kPa (50 in. w.c.) at volumetric air flow rates up to 113.3 m3/min (4000 CFM). Testing is performed at elevated and ambient conditions for temperature and relative humidity. Current testing utilizes three challenge aerosols: carbon black, alumina, and Arizona road dust (A1-Ultrafine). Each aerosol has a different mass median diameter to test loading over a wide range of particles sizes. The test stand is designed to monitor and maintain relative humidity and temperature to required specifications. Instrumentation is implemented on the upstream and downstream sections of the test stand as well as on the filter housing itself. Representative data are presented herein illustrating the test stand's capabilities. Digital images of the filter pack collected during and after testing is displayed after the representative data are discussed. In conclusion, the ICET test stand with AG-1 filter testing capabilities has been developed and hurdles such as test parameter stability and design flexibility overcome.

  17. Around Marshall

    NASA Image and Video Library

    1963-01-14

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the S-IC test stand, related facilities were constructed during this time frame. Built just north of the massive S-IC test stand was the F-1 Engine test stand. The F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo, taken January 14, 1963 depicts the F-1 test stand site with hoses pumping excess water from the site.

  18. 1. CAPTIVE TEST STAND D1 FROM THE FERROCEMENT APRON, VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. CAPTIVE TEST STAND D-1 FROM THE FERROCEMENT APRON, VIEW TOWARDS SOUTHEAST. - Glenn L. Martin Company, Titan Missile Test Facilities, Captive Test Stand D-1, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  19. 2. CLOSE UP OF CAPTIVE TEST STAND D4, VIEW TOWARDS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. CLOSE UP OF CAPTIVE TEST STAND D-4, VIEW TOWARDS NORTHEAST. - Glenn L. Martin Company, Titan Missile Test Facilities, Captive Test Stand D-4, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  20. 1. CAPTIVE TEST STAND D4, CONNECTING TUNNELS AT RIGHT, VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. CAPTIVE TEST STAND D-4, CONNECTING TUNNELS AT RIGHT, VIEW TOWARDS NORTHEAST. - Glenn L. Martin Company, Titan Missile Test Facilities, Captive Test Stand D-4, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  1. 51. HISTORIC GENERAL VIEW LOOKING WEST AT THE TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    51. HISTORIC GENERAL VIEW LOOKING WEST AT THE TEST STAND WITH THE MERCURY REDSTONE ROCKET FULLY ASSEMBLED AND BEING PREPARED FOR TESTING. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  2. Around Marshall

    NASA Image and Video Library

    1963-11-20

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo shows the progress of the F-1 Test Stand as of November 20, 1963.

  3. Around Marshall

    NASA Image and Video Library

    1963-04-04

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo, taken April 4, 1963 depicts the construction of the F-1 test stand foundation walls.

  4. Around Marshall

    NASA Image and Video Library

    1963-04-17

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo, taken April 17, 1963 depicts the construction of the F-1 test stand foundation walls.

  5. Credit BG. Test Stand "D" tower as seen looking northeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit BG. Test Stand "D" tower as seen looking northeast (See caption for CA-163-F-18). To the right of the view is the stainless steel dome top for Dv Cell (see CA-163-F-22 for view into cell), behind which rests a spherical accumulator--an electrically heated steam generator for powering the vacuum system at "C" and Test Stand "D." Part of the ejector system can be seen on the right corner of the tower, other connections include electrical ducts (thin, flat metal members) and fire protection systems. Note the stand in the foreground with lights used to indicate safety status of the stand during tests - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  6. ROBERT BOBO AND MIKE NICHOLS AT TEST STAND 4693

    NASA Image and Video Library

    2016-12-14

    ROBERT BOBO, LEFT, AND MIKE NICHOLS TALK BENEATH THE 221-FOOT-TALL TEST STAND 4693, THE LARGEST OF TWO NEW SPACE LAUNCH SYSTEM TEST STANDS AT MSFC. BOBO MANAGES SLS STRUCTURAL STRENGTH TESTING, AND NICHOLS IS LEAD TEST ENGINEER FOR THE SLS LIQUID HYDROGEN TANK.

  7. Numerical design of an EBIS collector to optimize electron collection and ion extraction

    NASA Astrophysics Data System (ADS)

    Dietrich, Jürgen

    1990-12-01

    For the Frankfurt EBIS (R. Becker et al., Nucl. Instr. and Meth. B24/25 (1987) 838, ref. [1]), a new collector was designed using the relativistic electron optics program EGUN (W.B. Herrmannsfeldt, SLAC-331 (1988), ref. [2]) and the magnetic field program INTMAG (R. Becker, Nucl. Instr. and Meth. B42 (1989) 303, ref. [3]). To model the fringing field of the main solenoid, a bucking coil and a cylindrical shim is provided. The current of the bucking coil and the position and shape of the shim are optimized with INTMAG for minimum fringing field to allow expansion of the electron beam by its space charge. The magnetic field data output from INTMAG is directly used as input for EGUN to calculate the electron and ion trajectories. The initial conditions for the trajectories were computed from the paraxial ray equation. Different operation modes of the collector are investigated including the behaviour of secondary electrons.

  8. ChEMBL web services: streamlining access to drug discovery data and utilities.

    PubMed

    Davies, Mark; Nowotka, Michał; Papadatos, George; Dedman, Nathan; Gaulton, Anna; Atkinson, Francis; Bellis, Louisa; Overington, John P

    2015-07-01

    ChEMBL is now a well-established resource in the fields of drug discovery and medicinal chemistry research. The ChEMBL database curates and stores standardized bioactivity, molecule, target and drug data extracted from multiple sources, including the primary medicinal chemistry literature. Programmatic access to ChEMBL data has been improved by a recent update to the ChEMBL web services (version 2.0.x, https://www.ebi.ac.uk/chembl/api/data/docs), which exposes significantly more data from the underlying database and introduces new functionality. To complement the data-focused services, a utility service (version 1.0.x, https://www.ebi.ac.uk/chembl/api/utils/docs), which provides RESTful access to commonly used cheminformatics methods, has also been concurrently developed. The ChEMBL web services can be used together or independently to build applications and data processing workflows relevant to drug discovery and chemical biology. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  9. Simulations of RF capture with barrier bucket in booster at injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gardner, C.J.

    2012-01-23

    As part of the effort to increase the number of ions per bunch in RHIC, a new scheme for RF capture of EBIS ions in Booster at injection has been developed. The scheme was proposed by M. Blaskiewicz and J.M. Brennan. It employs a barrier bucket to hold a half turn of beam in place during capture into two adjacent harmonic 4 buckets. After acceleration, this allows for 8 transfers of 2 bunches from Booster into 16 buckets on the AGS injection porch. During the Fall of 2011 the necessary hardware was developed and implemented by the RF and Controlsmore » groups. The scheme is presently being commissioned by K.L. Zeno with Au32+ ions from EBIS. In this note we carry out simulations of the RF capture. These are meant to serve as benchmarks for what can be achieved in practice. They also allow for an estimate of the longitudinal emittance of the bunches on the AGS injection porch.« less

  10. Retaining clients in an outcome monitoring evaluation study: HIV prevention efforts in community settings.

    PubMed

    Smith, Bryce D; Kalayil, Elizabeth J; Patel-Larson, Alpa; Chen, Brenda; Vaughan, Marla

    2012-02-01

    The Centers for Disease Control and Prevention (CDC), Division of HIV/AIDS Prevention (DHAP) conducted outcome monitoring studies on evidence-based interventions (EBIs) provided by CDC-funded community-based organizations (CBOs). Critical to the success of outcome monitoring was the ability of CBOs to recruit and retain clients in evaluation studies. Two EBIs, Video Opportunities for Innovative Condom Education and Safer Sex (VOICES/VOCES) and Healthy Relationships, were evaluated using repeated measure studies, which require robust follow-up retention rates to increase the validity and usefulness of the findings. The retention rates were high for both VOICES/VOCES CBOs (95.8% at 30 days and 91.1% at 120 days), and Healthy Relationships CBOs (89.5% at 90 days and 83.5% at 180 days). This paper presents an overview of the retention of clients, challenges to follow-up, and strategies developed by CBOs to achieve high retention rates. These strategies and rates are discussed within the context of the CBOs' target populations and communities. Published by Elsevier Ltd.

  11. 22. DETAIL, TWO LIGHTING TYPES AT REAR OF TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. DETAIL, TWO LIGHTING TYPES AT REAR OF TEST STAND 1-A. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  12. Around Marshall

    NASA Image and Video Library

    1963-08-13

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the construction of the F-1 test stand as of August 13, 1963. All four of its tower legs are well underway into the skyline.

  13. Credit BG. View looking southwest at Test Stand "D" complex. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit BG. View looking southwest at Test Stand "D" complex. In the background at left is the Steam Generator Plant 4280/E-81 built in 1972 to house four gas-fired Clayton flash boilers. The boilers were later supplemented by the electrically heated steam accumulator (sphere) to supply steam to the various ejectors at Test Stand "D" vacuum test cells - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  14. Intracranial hemorrhage alters scalp potential distribution in bioimpedance cerebral monitoring: Preliminary results from FEM simulation on a realistic head model and human subjects

    PubMed Central

    Atefi, Seyed Reza; Seoane, Fernando; Kamalian, Shervin; Rosenthal, Eric S.; Lev, Michael H.; Bonmassar, Giorgio

    2016-01-01

    Purpose: Current diagnostic neuroimaging for detection of intracranial hemorrhage (ICH) is limited to fixed scanners requiring patient transport and extensive infrastructure support. ICH diagnosis would therefore benefit from a portable diagnostic technology, such as electrical bioimpedance (EBI). Through simulations and patient observation, the authors assessed the influence of unilateral ICH hematomas on quasisymmetric scalp potential distributions in order to establish the feasibility of EBI technology as a potential tool for early diagnosis. Methods: Finite element method (FEM) simulations and experimental left–right hemispheric scalp potential differences of healthy and damaged brains were compared with respect to the asymmetry caused by ICH lesions on quasisymmetric scalp potential distributions. In numerical simulations, this asymmetry was measured at 25 kHz and visualized on the scalp as the normalized potential difference between the healthy and ICH damaged models. Proof-of-concept simulations were extended in a pilot study of experimental scalp potential measurements recorded between 0 and 50 kHz with the authors’ custom-made bioimpedance spectrometer. Mean left–right scalp potential differences recorded from the frontal, central, and parietal brain regions of ten healthy control and six patients suffering from acute/subacute ICH were compared. The observed differences were measured at the 5% level of significance using the two-sample Welch t-test. Results: The 3D-anatomically accurate FEM simulations showed that the normalized scalp potential difference between the damaged and healthy brain models is zero everywhere on the head surface, except in the vicinity of the lesion, where it can vary up to 5%. The authors’ preliminary experimental results also confirmed that the left–right scalp potential difference in patients with ICH (e.g., 64 mV) is significantly larger than in healthy subjects (e.g., 20.8 mV; P < 0.05). Conclusions: Realistic, proof-of-concept simulations confirmed that ICH affects quasisymmetric scalp potential distributions. Pilot clinical observations with the authors’ custom-made bioimpedance spectrometer also showed higher left–right potential differences in the presence of ICH, similar to those of their simulations, that may help to distinguish healthy subjects from ICH patients. Although these pilot clinical observations are in agreement with the computer simulations, the small sample size of this study lacks statistical power to exclude the influence of other possible confounders such as age, sex, and electrode positioning. The agreement with previously published simulation-based and clinical results, however, suggests that EBI technology may be potentially useful for ICH detection. PMID:26843231

  15. 9. BUILDING 8769, EAST REAR AND NORTH SIDE, TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. BUILDING 8769, EAST REAR AND NORTH SIDE, TEST STAND AT RIGHT. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunkers for Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  16. 3. EAST SIDE, ALSO SHOWING COVERED TANKS AND TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. EAST SIDE, ALSO SHOWING COVERED TANKS AND TEST STAND 1-5 AT RIGHT. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-4, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  17. Association of unipedal standing time and bone mineral density in community-dwelling Japanese women.

    PubMed

    Sakai, A; Toba, N; Takeda, M; Suzuki, M; Abe, Y; Aoyagi, K; Nakamura, T

    2009-05-01

    Bone mineral density (BMD) and physical performance of the lower extremities decrease with age. In community-dwelling Japanese women, unipedal standing time, timed up and go test, and age are associated with BMD while in women aged 70 years and over, unipedal standing time is associated with BMD. The aim of this study was to clarify whether unipedal standing time is significantly associated with BMD in community-dwelling women. The subjects were 90 community-dwelling Japanese women aged 54.7 years. BMD of the second metacarpal bone was measured by computed X-ray densitometry. We measured unipedal standing time as well as timed up and go test to assess physical performance of the lower extremities. Unipedal standing time decreased with increased age. Timed up and go test significantly correlated with age. Low BMD was significantly associated with old age, short unipedal standing time, and long timed up and go test. Stepwise regression analysis revealed that age, unipedal standing time, and timed up and go test were significant factors associated with BMD. In 21 participants aged 70 years and over, body weight and unipedal standing time, but not age, were significantly associated with BMD. BMD and physical performance of the lower extremities decrease with older age. Unipedal standing time, timed up and go test, and age are associated with BMD in community-dwelling Japanese women. In women aged 70 years and over, unipedal standing time is significantly associated with BMD.

  18. 2. Credit JPL. Photographic copy of photograph, looking northeast at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Credit JPL. Photographic copy of photograph, looking northeast at unfinished original Test Stand 'C' construction. A portion of the corrugated steel tunnel tube connecting Test Stand 'C' to the first phase of JPL tunnel system construction is visible in the foreground. The steel frame used to support propellant tanks and engine equipment has been erected. The open trap door leads to a chamber inside the Test Stand 'C' base where gaseous nitrogen is distributed via manifolds to Test Stand 'C' control valves. (JPL negative no. 384-1568-A, 19 March 1957) - Jet Propulsion Laboratory Edwards Facility, Test Stand C, Edwards Air Force Base, Boron, Kern County, CA

  19. Measurement properties and feasibility of clinical tests to assess sit-to-stand/stand-to-sit tasks in subjects with neurological disease: a systematic review

    PubMed Central

    Silva, Paula F. S.; Quintino, Ludmylla F.; Franco, Juliane; Faria, Christina D. C. M.

    2014-01-01

    Background Subjects with neurological disease (ND) usually show impaired performance during sit-to-stand and stand-to-sit tasks, with a consequent reduction in their mobility levels. Objective To determine the measurement properties and feasibility previously investigated for clinical tests that evaluate sit-to-stand and stand-to-sit in subjects with ND. Method A systematic literature review following the PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) protocol was performed. Systematic literature searches of databases (MEDLINE/SCIELO/LILACS/PEDro) were performed to identify relevant studies. In all studies, the following inclusion criteria were assessed: investigation of any measurement property or the feasibility of clinical tests that evaluate sit-to-stand and stand-to-sit tasks in subjects with ND published in any language through December 2012. The COSMIN checklist was used to evaluate the methodological quality of the included studies. Results Eleven studies were included. The measurement properties/feasibility were most commonly investigated for the five-repetition sit-to-stand test, which showed good test-retest reliability (Intraclass Correlation Coefficient:ICC=0.94-0.99) for subjects with stroke, cerebral palsy and dementia. The ICC values were higher for this test than for the number of repetitions in the 30-s test. The five-repetition sit-to-stand test also showed good inter/intra-rater reliabilities (ICC=0.97-0.99) for stroke and inter-rater reliability (ICC=0.99) for subjects with Parkinson disease and incomplete spinal cord injury. For this test, the criterion-related validity for subjects with stroke, cerebral palsy and incomplete spinal cord injury was, in general, moderate (correlation=0.40-0.77), and the feasibility and safety were good for subjects with Alzheimer's disease. Conclusions The five-repetition sit-to-stand test was used more often in subjects with ND, and most of the measurement properties were investigated and showed adequate results. PMID:24839043

  20. Last SSME test on A-1

    NASA Image and Video Library

    2006-09-29

    The Stennis Space Center conducted the final space shuttle main engine test on its A-1 Test Stand Friday. The A-1 Test Stand was the site of the first test on a shuttle main engine in 1975. Stennis will continue testing shuttle main engines on its A-2 Test Stand through the end of the Space Shuttle Program in 2010. The A-1 stand begins a new chapter in its operational history in October. It will be temporarily decommissioned to convert it for testing the J-2X engine, which will power the upper stage of NASA's new crew launch vehicle, the Ares I. Although this ends the stand's work on the Space Shuttle Program, it will soon be used for the rocket that will carry America's next generation human spacecraft, Orion.

  1. 45. HISTORIC AERIAL VIEW LOOKING SOUTHWEST AT THE TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    45. HISTORIC AERIAL VIEW LOOKING SOUTHWEST AT THE TEST STAND AND THE SURROUNDING ELECTRONICS AND EQUIPMENT TRAILERS. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  2. Construction Progress of the S-IC Test Stand Complex Bunker House

    NASA Technical Reports Server (NTRS)

    1963-01-01

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army's Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the S-IC stand, additional related facilities were built during this time frame. Built to the east of the S-IC stand, the block house served as the control room. To the south of the blockhouse was a newly constructed pump house used for delivering water to the S-IC stand during testing. North of the massive test stand, the F-1 Engine test stand was built for testing a single F-1 engine. Just southeast of the S-IC stand a concrete bunker house was constructed. The bunker housed an emergency crew clad in fire proof gear, who were close at hand should any emergencies arise during testing. This photo of the completed bunker house was taken on May 7, 1963.

  3. A-3 Test Stand construction moves forward

    NASA Image and Video Library

    2010-07-13

    Work on the A-3 Test Stand at Stennis Space Center took a step forward in July with delivery of the first-stage steam ejector July 13. Stennis employees are shown preparing the ejector to be lifted into place on the test stand. When activated in 2012, the A-3 Test Stand will allow operators to test rocket engines at simulated altitudes of 100,000 feet, a critical feature for next-generation engines that will take humans beyond low-Earth orbit once more.

  4. 5. BUILDING 8768, SOUTH SIDE AND EAST REAR. TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. BUILDING 8768, SOUTH SIDE AND EAST REAR. TEST STAND 1A AT LEFT. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunkers for Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  5. 21. Building 202, underside of test stand A, detail of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. Building 202, underside of test stand A, detail of junction of scrubber structure and test stand with water pipes and valves visible. View looking southeast. - Rocket Engine Testing Facility, GRC Building No. 202, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH

  6. 37. HISTORIC GENERAL VIEW LOOKING WEST OF TEST STAND AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. HISTORIC GENERAL VIEW LOOKING WEST OF TEST STAND AND ROCKET DURING TEST FIRING NUMBER 2. NOTE THE FLAME BEING EMITTED FROM THE BOTTOM OF THE ROCKET. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  7. 8. VIEW LOOKING WEST AT THE POWER PLANT TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. VIEW LOOKING WEST AT THE POWER PLANT TEST STAND DURING AN ENGINE FIRING. DATE UNKNOWN, FRED ORDWAY COLLECTION, U.S. SPACE AND ROCKET CENTER, HUNTSVILLE, AL. - Marshall Space Flight Center, East Test Area, Power Plant Test Stand, Huntsville, Madison County, AL

  8. 10. "TEST STAND 15, AIR FORCE FLIGHT TEST CENTER." ca. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. "TEST STAND 1-5, AIR FORCE FLIGHT TEST CENTER." ca. 1958. Test Area 1-115. Original is a color print, showing Test Stand 1-5 from below, also showing the superstructure of TS1-4 at left. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA

  9. Stennis Space Center Conducts Water Flow Test On The B-2 Test Stand

    NASA Image and Video Library

    2018-05-04

    Stennis Space Center completed a water flow test of the refurbished B-2 Test Stand on May 4, 2018. This included both the deflector and the aspirator, individually and together. This test stand is being prepared for the testing of the Space Launch System's booster core, which will utilize four RS-25 rocket engines.

  10. SSC Test Operations Contract Overview

    NASA Technical Reports Server (NTRS)

    Kleim, Kerry D.

    2010-01-01

    This slide presentation reviews the Test Operations Contract at the Stennis Space Center (SSC). There are views of the test stands layouts, and closer views of the test stands. There are descriptions of the test stand capabilities, some of the other test complexes, the Cryogenic propellant storage facility, the High Pressure Industrial Water (HPIW) facility, and Fluid Component Processing Facility (FCPF).

  11. Linked randomised controlled trials of face-to-face and electronic brief intervention methods to prevent alcohol related harm in young people aged 14-17 years presenting to Emergency Departments (SIPS junior).

    PubMed

    Deluca, Paolo; Coulton, Simon; Alam, M Fasihul; Cohen, David; Donoghue, Kim; Gilvarry, Eilish; Kaner, Eileen; Maconochie, Ian; McArdle, Paul; McGovern, Ruth; Newbury-Birch, Dorothy; Patton, Robert; Phillips, Ceri; Phillips, Thomas; Russell, Ian; Strang, John; Drummond, Colin

    2015-04-10

    Alcohol is a major global threat to public health. Although the main burden of chronic alcohol-related disease is in adults, its foundations often lie in adolescence. Alcohol consumption and related harm increase steeply from the age of 12 until 20 years. Several trials focusing upon young people have reported significant positive effects of brief interventions on a range of alcohol consumption outcomes. A recent review of reviews also suggests that electronic brief interventions (eBIs) using internet and smartphone technologies may markedly reduce alcohol consumption compared with minimal or no intervention controls. Interventions that target non-drinking youth are known to delay the onset of drinking behaviours. Web based alcohol interventions for adolescents also demonstrate significantly greater reductions in consumption and harm among 'high-risk' drinkers; however changes in risk status at follow-up for non-drinkers or low-risk drinkers have not been assessed in controlled trials of brief alcohol interventions. The study design comprises two linked randomised controlled trials to evaluate the effectiveness and cost-effectiveness of two intervention strategies compared with screening alone. One trial will focus on high-risk adolescent drinkers attending Emergency Departments (Eds) and the other will focus on those identified as low-risk drinkers or abstinent from alcohol but attending the same ED. Our primary (null) hypothesis is similar for both trials: Personalised Feedback and Brief Advice (PFBA) and Personalised Feedback plus electronic Brief Intervention (eBI) are no more effective than screening alone in alcohol consumed at 12 months after randomisation as measured by the Time-Line Follow-Back 28-day version. Our secondary (null) hypothesis relating to economics states that PFBA and eBI are no more cost-effective than screening alone. In total 1,500 participants will be recruited into the trials, 750 high-risk drinkers and 750 low-risk drinkers or abstainers. Participants will be randomised with equal probability, stratified by centre, to either a screening only control group or one of the two interventions: single session of PFBA or eBI. All participants will be eligible to receive treatment as usual in addition to any trial intervention. Individual participants will be followed up at 6 and 12 months after randomisation. The protocol represents an ambitious innovative programme of work addressing alcohol use in the adolescent population. ISRCTN45300218. Registered 5th July 2014.

  12. A-3 Test Stand work

    NASA Image and Video Library

    2011-07-29

    Rocket engine propellant tanks and cell dome top the A-3 Test Stand under construction at Stennis Space Center. The stand will test next-generation rocket engines that could carry humans beyond low-Earth orbit into deep space once more.

  13. 40 CFR 63.9285 - Am I subject to this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands What This Subpart... engine test cell/stand that is located at a major source of HAP emissions. (a) An engine test cell/stand...

  14. 40 CFR 63.9285 - Am I subject to this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands What This Subpart... engine test cell/stand that is located at a major source of HAP emissions. (a) An engine test cell/stand...

  15. 40 CFR 63.9285 - Am I subject to this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands What This Subpart... engine test cell/stand that is located at a major source of HAP emissions. (a) An engine test cell/stand...

  16. 40 CFR 63.9285 - Am I subject to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands What This Subpart... engine test cell/stand that is located at a major source of HAP emissions. (a) An engine test cell/stand...

  17. 40 CFR 63.9285 - Am I subject to this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands What This Subpart... engine test cell/stand that is located at a major source of HAP emissions. (a) An engine test cell/stand...

  18. Saturn Apollo Program

    NASA Image and Video Library

    1964-10-01

    Test firing of the Saturn I S-I Stage (S-1-10) at the Marshall Space Flight Center. This test stand was originally constructed in 1951 and sometimes called the Redstone or T tower. In l961, the test stand was modified to permit static firing of the S-I/S-IB stages, which produced a total thrust of 1,600,000 pounds. The name of the stand was then changed to the S-IB Static Test Stand.

  19. Use of a unipedal standing test to assess the ambulation reacquisition time during the early postoperative stage after hip fracture in elderly Japanese: prospective study.

    PubMed

    Murata, Koichi; Sugitani, Shigeki; Yoshioka, Hiroki; Noguchi, Takashi; Aoto, Toshiyuki; Nakamura, Takashi

    2010-01-01

    The aim of this study was to predict the ambulation reacquisition time after hip fracture in elderly people using the unipedal standing test during the early postoperative stage. Patients with an intertrochanteric fracture treated with internal fixation (n = 35) and patients with a femoral neck fracture treated with hemiarthroplasty (n = 22) were included. A unipedal standing test using the nonoperated leg was performed on days 3 and 7 after the operation. Among the patients with an intertrochanteric fracture, those with a positive result on the unipedal standing test on postoperative day (POD) 3 attained gait with parallel guide bars (BG) and walker-assisted gait (WG) significantly earlier than did patients with a negative result on the unipedal standing test. Patients with a positive result on the unipedal standing test on POD 7 attained BG, WG, and cane-assisted gait (CG) significantly earlier than did patients with a negative test. Among patients with a femoral neck fracture, those with a positive unipedal standing test result on POD 3 attained BG, WG, and CG significantly earlier than did patients with a negative test. Those with a positive test result on POD 7 attained BG, WG, and CG significantly earlier than did patients with a negative test. The unipedal standing test given during the early postoperative stage is a good test for predicting the ambulation reacquisition time. Moreover, it gives information that can help determine the need for subacute rehabilitation and about discharge planning and health service provision.

  20. NASA Johnson Space Center: White Sands Test Facility

    NASA Technical Reports Server (NTRS)

    Aggarwal, Pravin; Kowalski, Robert R.

    2011-01-01

    This slide presentation reviews the testing facilities and laboratories available at the White Sands Test Facility (WSTF). The mission of WSTF is to provide the expertise and infrastructure to test and evaluate spacecraft materials, components and propulsion systems that enable the safe exploration and use of space. There are nine rocket test stands in two major test areas, six altitude test stands, three ambient test stands,

  1. 17. HISTORIC VIEW OF ROCKET & LAUNCH STAND DESIGNED BY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. HISTORIC VIEW OF ROCKET & LAUNCH STAND DESIGNED BY HERMANN OBERTH AND RUDOLF NEBEL FOR THE MOVIE DIE FRAU IM MOND (THE WOMAN ON THE MOON). THE LAUNCH STAND WAS MODIFIED BY THE VFR FOR THE FIRST TEST STAND AT RAKETENFLUGPLATZ NEAR BERLIN. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  2. 1. ROCKET ENGINE TEST STAND, LOCATED IN THE NORTHEAST ¼ ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. ROCKET ENGINE TEST STAND, LOCATED IN THE NORTHEAST ¼ OF THE X-15 ENGINE TEST COMPLEX. Looking northeast. - Edwards Air Force Base, X-15 Engine Test Complex, Rocket Engine & Complete X-15 Vehicle Test Stands, Rogers Dry Lake, east of runway between North Base & South Base, Boron, Kern County, CA

  3. 3. COMPLETE X15 VEHICLE TEST STAND, LOCATED IN SOUTHEAST ¼ ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. COMPLETE X-15 VEHICLE TEST STAND, LOCATED IN SOUTHEAST ¼ OF X-15 ENGINE TEST COMPLEX. Looking northeast. - Edwards Air Force Base, X-15 Engine Test Complex, Rocket Engine & Complete X-15 Vehicle Test Stands, Rogers Dry Lake, east of runway between North Base & South Base, Boron, Kern County, CA

  4. CSG delivery and installation

    NASA Image and Video Library

    2010-10-27

    The first of nine chemical steam generator (CSG) units that will be used on the A-3 Test Stand is hoisted into place at the E-2 Test Stand at John C. Stennis Space Center on Oct. 24, 2010. The unit was installed at the E-2 stand for verification and validation testing before it is moved to the A-3 stand. Steam generated by the nine CSG units that will be installed on the A-3 stand will create a vacuum that allows Stennis operators to test next-generation rocket engines at simulated altitudes up to 100,000 feet.

  5. 3. BUILDING 8767, NORTH REAR AND WEST SIDE, TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. BUILDING 8767, NORTH REAR AND WEST SIDE, TEST STAND 1-A AT FAR RIGHT. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunkers for Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  6. 5. FLAME DEFLECTOR, COMPLETE X15 VEHICLE TEST STAND. Looking east. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. FLAME DEFLECTOR, COMPLETE X-15 VEHICLE TEST STAND. Looking east. - Edwards Air Force Base, X-15 Engine Test Complex, Rocket Engine & Complete X-15 Vehicle Test Stands, Rogers Dry Lake, east of runway between North Base & South Base, Boron, Kern County, CA

  7. Effectiveness of a multi-level implementation strategy for ASD interventions: study protocol for two linked cluster randomized trials.

    PubMed

    Brookman-Frazee, Lauren; Stahmer, Aubyn C

    2018-05-09

    The Centers for Disease Control (2018) estimates that 1 in 59 children has autism spectrum disorder, and the annual cost of ASD in the U.S. is estimated to be $236 billion. Evidence-based interventions have been developed and demonstrate effectiveness in improving child outcomes. However, research on generalizable methods to scale up these practices in the multiple service systems caring for these children has been limited and is critical to meet this growing public health need. This project includes two, coordinated studies testing the effectiveness of the Translating Evidence-based Interventions (EBI) for ASD: Multi-Level Implementation Strategy (TEAMS) model. TEAMS focuses on improving implementation leadership, organizational climate, and provider attitudes and motivation in order to improve two key implementation outcomes-provider training completion and intervention fidelity and subsequent child outcomes. The TEAMS Leadership Institute applies implementation leadership strategies and TEAMS Individualized Provider Strategies for training applies motivational interviewing strategies to facilitate provider and organizational behavior change. A cluster randomized implementation/effectiveness Hybrid, type 3, trial with a dismantling design will be used to understand the effectiveness of TEAMS and the mechanisms of change across settings and participants. Study #1 will test the TEAMS model with AIM HI (An Individualized Mental Health Intervention for ASD) in publicly funded mental health services. Study #2 will test TEAMS with CPRT (Classroom Pivotal Response Teaching) in education settings. Thirty-seven mental health programs and 37 school districts will be randomized, stratified by county and study, to one of four groups (Standard Provider Training Only, Standard Provider Training + Leader Training, Enhanced Provider Training, Enhanced Provider Training + Leader Training) to test the effectiveness of combining standard, EBI-specific training with the two TEAMS modules individually and together on multiple implementation outcomes. Implementation outcomes including provider training completion, fidelity (coded by observers blind to group assignment) and child behavior change will be examined for 295 mental health providers, 295 teachers, and 590 children. This implementation intervention has the potential to increase quality of care for ASD in publicly funded settings by improving effectiveness of intervention implementation. The process and modules will be generalizable to multiple service systems, providers, and interventions, providing broad impact in community services. This study is registered with Clinicaltrials.gov ( NCT03380078 ). Registered 20 December 2017, retrospectively registered.

  8. Credit WCT. Photographic copy of photograph, view looking south down ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit WCT. Photographic copy of photograph, view looking south down easternmost tunnel axis during second phase of JPL tunnel construction in 1959. Reinforced concrete formwork for Test Stand "D" foundation appears in left foreground. Formwork for Building 4222/E-23 (Test Stand "D" Workshop) is in place in right foreground with disturbed earth for western leg of tunnel system evident in background. Test Stand "C" is in center background, where first phase of tunnel construction ended. Test Stand "A" appears as tower in right background. (JPL negative no. 384-1838-C, 9 March 1959) - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  9. 10. OBSERVATION POST NO. 3, WEST OF TEST STAND 1A. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. OBSERVATION POST NO. 3, WEST OF TEST STAND 1-A. SOUTH SIDE AND EAST FRONT. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunkers for Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  10. Detail of north side of Test Stand 'A' base, showing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail of north side of Test Stand 'A' base, showing tanks for distilled water (left), fuel (center), and gaseous nitrogen (right). Other tanks present for tests were removed before this image was taken. - Jet Propulsion Laboratory Edwards Facility, Test Stand A, Edwards Air Force Base, Boron, Kern County, CA

  11. 6. CABLE RACK, MEZZANINE LEVEL, INTERIOR OF TEST STAND 1A. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. CABLE RACK, MEZZANINE LEVEL, INTERIOR OF TEST STAND 1A. Looking south from north wall of terminal room. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  12. 7. ROCKET SLED ON DECK OF TEST STAND 15. Photo ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. ROCKET SLED ON DECK OF TEST STAND 1-5. Photo no. "6085, G-EAFB-16 SEP 52." Looking south to machine shop. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-5, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  13. KEITH HIGGINBOTHAM AT TEST STAND 4699

    NASA Image and Video Library

    2016-10-17

    KEITH HIGGINBOTHAM, STRUCTURAL TEST LEAD FOR THE SLS SPACECRAFT PAYLOAD INTEGRATION AND EVOLUTION OFFICE, IS SHOWN BESIDE TEST STAND 4699 AT THE MARSHALL SPACE FLIGHT CENTER’S WEST TEST AREA. HIGGINBOTHAM WILL BE LEADING STRUCTURAL LOADS TESTING AT TEST STAND 4699 FOR THE CORE STAGE SIMULATER AND THE LAUNCH VEHICLE STAGE ADAPTER. THE TEST SERIES WILL ENSURE EACH STRUCTURE CAN WITHSTAND THE INCREDIBLE STRESSES OF LAUNCH.

  14. LOX tank installation

    NASA Image and Video Library

    2011-06-08

    Construction of the A-3 Test Stand at Stennis Space Center continued June 8 with installation of a 35,000-gallon liquid oxygen tank atop the steel structure. The stand is being built to test next-generation rocket engines that will carry humans into deep space once more. The LOX tank and a liquid hydrogen tank to be installed atop the stand later will provide propellants for testing the engines. The A-3 Test Stand is scheduled for completion and activation in 2013.

  15. Preparing to Test

    NASA Image and Video Library

    2015-03-26

    Stennis Space Center employees install a 96-inch valve during a recent upgrade of the high-pressure industrial water system that serves the site’s large rocket engine test stands. The upgraded system has a capacity to flow 335,000 gallons of water a minute, which is a critical element for testing. At Stennis, engines are anchored in place on large test stands and fired just as they are during an actual space flight. The fire and exhaust from the test is redirected out of the stand by a large flame trench. A water deluge system directs thousands of gallons of water needed to cool the exhaust. Water also must be available for fire suppression in the event of a mishap. The new system supports RS-25 engine testing on the A-1 Test Stand, as well as testing of the core stage of NASA’s new Space Launch System on the B-2 Test Stand at Stennis.

  16. Acute cardiac support with intravenous milrinone promotes recovery from early brain injury in a murine model of severe subarachnoid haemorrhage.

    PubMed

    Mutoh, Tomoko; Mutoh, Tatsushi; Nakamura, Kazuhiro; Yamamoto, Yukiko; Tsuru, Yoshiharu; Tsubone, Hirokazu; Ishikawa, Tatsuya; Taki, Yasuyuki

    2017-04-01

    Early brain injury/ischaemia (EBI) is a serious complication early after subarachnoid haemorrhage (SAH) that contributes to development of delayed cerebral ischaemia (DCI). This study aimed to determine the role of inotropic cardiac support using milrinone (MIL) on restoring acute cerebral hypoperfusion attributable to EBI and improving outcomes after experimental SAH. Forty-three male C57BL/6 mice were assigned to either sham surgery (SAH-sham), SAH induced by endovascular perforation plus postconditioning with 2% isoflurane (Control), or SAH plus isoflurane combined with MIL with and without hypoxia-inducible factor inhibitor (HIF-I) pretreatment. Cardiac output (CO) during intravenous MIL infusion (0.25-0.75 μg/kg/min) between 1.5 and 2.5 hours after SAH induction was monitored with Doppler echocardiography. Magnetic resonance imaging (MRI)-continuous arterial spin labelling was used for quantitative cerebral blood flow (CBF) measurements. Neurobehavioral function was assessed daily by neurological score and open field test. DCI was analyzed 3 days later by determining infarction on MRI. Mild reduction of cardiac output (CO) and global cerebral blood flow (CBF) depression were notable early after SAH. MIL increased CO in a dose-dependent manner (P<.001), which was accompanied by improved hypoperfusion, incidence of DCI and functional recovery than Control (P<.05). The neuroprotective effects afforded by MIL or Control were attenuated by hypoxia-inducible factor (HIF) inhibition (P<.05). These results suggest that MIL improves acute hypoperfusion by its inotropic effect, leading to neurobehavioral improvement in mice after severe SAH, in which HIF may be acting as a critical mediator. © 2017 John Wiley & Sons Australia, Ltd.

  17. [Research and workshop on alternative fuels for aviation. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1999-09-01

    The Renewable Aviation Fuels Development Center (RAFDC) at Baylor University was granted U. S. Department of Energy (US DOE) and Federal Aviation Administration (FAA) funds for research and development to improve the efficiency in ethanol powered aircraft, measure performance and compare emissions of ethanol, Ethyl Tertiary Butyl Ether (ETBE) and 100 LL aviation gasoline. The premise of the initial proposal was to use a test stand owned by Engine Components Inc. (ECI) based in San Antonio, Texas. After the grant was awarded, ECI decided to close down its test stand facility. Since there were no other test stands available atmore » that time, RAFDC was forced to find additional support to build its own test stand. Baylor University provided initial funds for the test stand building. Other obstacles had to be overcome in order to initiate the program. The price of the emission testing equipment had increased substantially beyond the initial quote. Rosemount Analytical Inc. gave RAFDC an estimate of $120,000.00 for a basic emission testing package. RAFDC had to find additional funding to purchase this equipment. The electronic ignition unit also presented a series of time consuming problems. Since at that time there were no off-the-shelf units of this type available, one had to be specially ordered and developed. FAA funds were used to purchase a Super Flow dynamometer. Due to the many unforeseen obstacles, much more time and effort than originally anticipated had to be dedicated to the project, with much of the work done on a volunteer basis. Many people contributed their time to the program. One person, mainly responsible for the initial design of the test stand, was a retired engineer from Allison with extensive aircraft engine test stand experience. Also, many Baylor students volunteered to assemble the. test stand and continue to be involved in the current test program. Although the program presented many challenges, which resulted in delays, the RAFDC's test stand is an asset which provides an ongoing research capability dedicated to the testing of alternative fuels for aircraft engines. The test stand is now entirely functional with the exception of the electronic ignition unit which still needs adjustments.« less

  18. Capacity Building: Evidence-Based Practice and Adolescents on the Autism Spectrum

    ERIC Educational Resources Information Center

    Rue, Hanna C.; Knox, Maria

    2013-01-01

    Empirical research in the treatment of autism spectrum disorders (ASDs) has resulted in the identification of numerous evidence-based interventions (EBIs). Adolescents with an ASD are faced with unique academic challenges, complex social environments, and physiological changes. They often require interventions to aid in acclimating to their…

  19. 76 FR 18553 - Agency Forms Undergoing Paperwork Reduction Act Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-04

    .... Women Involved in Life Learning from Other Women (WILLOW) is an EBI that focuses on health education and.... Proposed Project Community-based Organization (CBO) Monitoring and Evaluation Project (CMEP) of Women Involved in Life Learning from Other Women (WILLOW)--New--National Center for HIV/AIDS, Viral Hepatitis...

  20. B-1 and B-3 Test Stands at NASA’s Plum Brook Station

    NASA Image and Video Library

    1966-09-21

    Operation of the High Energy Rocket Engine Research Facility (B-1), left, and Nuclear Rocket Dynamics and Control Facility (B-3) at the National Aeronautics and Space Administration’s (NASA) Plum Brook Station in Sandusky, Ohio. The test stands were constructed in the early 1960s to test full-scale liquid hydrogen fuel systems in simulated altitude conditions. Over the next decade each stand was used for two major series of liquid hydrogen rocket tests: the Nuclear Engine for Rocket Vehicle Application (NERVA) and the Centaur second-stage rocket program. The different components of these rocket engines could be studied under flight conditions and adjusted without having to fire the engine. Once the preliminary studies were complete, the entire engine could be fired in larger facilities. The test stands were vertical towers with cryogenic fuel and steam ejector systems. B-1 was 135 feet tall, and B-3 was 210 feet tall. Each test stand had several levels, a test section, and ground floor shop areas. The test stands relied on an array of support buildings to conduct their tests, including a control building, steam exhaust system, and fuel storage and pumping facilities. A large steam-powered altitude exhaust system reduced the pressure at the exhaust nozzle exit of each test stand. This allowed B-1 and B-3 to test turbopump performance in conditions that matched the altitudes of space.

  1. Vestibular ataxia and its measurement in man

    NASA Technical Reports Server (NTRS)

    Fregly, A. R.

    1974-01-01

    Methods involved in and results obtained with a new comprehensive ataxia test battery are described, and definitions of spontaneous and induced vestibular ataxia in man are given in terms of these findings. In addition, the topic of alcohol-induced ataxia in relation to labyrinth function is investigated. Items in the test battery comprise a sharpened Romberg test, in which the subject stands on the floor with eyes closed and arms folded against his chest, feet heel-to-toe, for 60 seconds; an eyes-open walking test; an eyes-open standing test; an eyes-closed standing test; an eyes-closed on-leg standing test; an eyes-closed walk a line test; an eyes-closed heel-to-toe walking test; and supplementary ataxia tests such as the classical Romberg test.

  2. Impact of Fibromyalgia in the Sit-to-Stand-to-Sit Performance Compared With Healthy Controls.

    PubMed

    Collado-Mateo, Daniel; Adsuar, Jose C; Dominguez-Muñoz, Francisco J; Olivares, Pedro R; Gusi, Narcis

    2017-06-01

    Fibromyalgia is associated with a reduction in the ability to perform activities of daily living. Sit-to-stand-to-sit performance is one of the most common activities of daily living and often is evaluated by counting the number of repetitions of the 30-second chair-stand test. No study, however, has examined the performance over the 30 seconds of this test of female patients with fibromyalgia on a phase-by-phase basis. To evaluate the impact of fibromyalgia on performance of the 30-second chair-stand test and to analyze how the kinematic performance changed over the 30-second test period. A cross-sectional study. Local association of fibromyalgia. Fifteen females with fibromyalgia and nine healthy female controls. Participants performed the 30-second chair-stand test while wearing a motion capture device. Duration of each sit-to-stand-to-sit phase within the 30-second time limit was compared between groups using repeated measures analysis of variance. The association between duration of phases and scores from the revised version of the Fibromyalgia Impact Questionnaire was tested using bivariate correlations. The duration of impulse and sit-to-stand phases were gradually increased over the 30 seconds of the chair-stand test for women with fibromyalgia compared with healthy controls (P = .04 and P = .02, respectively). The mean duration of these 2 phases was associated with symptom duration and the function domain of the revised version of the Fibromyalgia Impact Questionnaire (P < .05). Also, stiffness was directly associated with the duration of the stand-up phase (P = .04). Kinematic performance during the 30-second chair-stand test differed between women with fibromyalgia and healthy controls. Since sit-to-stand from a chair is a common daily activity, women with fibromyalgia may require specific exercises to improve performance of this task. Not applicable. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  3. Isopropyl alcohol tank installed at A-3 Test Stand

    NASA Technical Reports Server (NTRS)

    2009-01-01

    An isopropyl alcohol (IPA) tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen IPA, water and liquid oxygen (LOX) tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  4. Water tank installed at A-3 Test Stand

    NASA Technical Reports Server (NTRS)

    2009-01-01

    A water tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen water, liquid oxygen (LOX) and isopropyl alcohol (IPA) tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  5. Liquid oxygen tank installed at A-3 Test Stand

    NASA Technical Reports Server (NTRS)

    2009-01-01

    A liquid oxygen (LOX) tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen LOX, isopropyl alcohol (IPA) and water tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  6. Water tank installed at A-3 Test Stand

    NASA Image and Video Library

    2009-08-13

    A water tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen water, liquid oxygen (LOX) and isopropyl alcohol (IPA) tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  7. Liquid oxygen tank installed at A-3 Test Stand

    NASA Image and Video Library

    2009-09-18

    A liquid oxygen (LOX) tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen LOX, isopropyl alcohol (IPA) and water tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  8. Isopropyl alcohol tank installed at A-3 Test Stand

    NASA Image and Video Library

    2009-09-18

    An isopropyl alcohol (IPA) tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen IPA, water and liquid oxygen (LOX) tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  9. Modal Analysis with the Mobile Modal Testing Unit

    NASA Technical Reports Server (NTRS)

    Wilder, Andrew J.

    2013-01-01

    Recently, National Aeronautics and Space Administration's (NASA's) White Sands Test Facility (WSTF) has tested rocket engines with high pulse frequencies. This has resulted in the use of some of WSTF's existing thrust stands, which were designed for static loading, in tests with large dynamic forces. In order to ensure that the thrust stands can withstand the dynamic loading of high pulse frequency engines while still accurately reporting the test data, their vibrational modes must be characterized. If it is found that they have vibrational modes with frequencies near the pulsing frequency of the test, then they must be modified to withstand the dynamic forces from the pulsing rocket engines. To make this determination the Mobile Modal Testing Unit (MMTU), a system capable of determining the resonant frequencies and mode shapes of a structure, was used on the test stands at WSTF. Once the resonant frequency has been determined for a test stand, it can be compared to the pulse frequency of a test engine to determine whether or not that stand can avoid resonance and reliably test that engine. After analysis of test stand 406 at White Sands Test Facility, it was determined that natural frequencies for the structure are located around 75, 125, and 240 Hz, and thus should be avoided during testing.

  10. Robot-operated quality control station based on the UTT method

    NASA Astrophysics Data System (ADS)

    Burghardt, Andrzej; Kurc, Krzysztof; Szybicki, Dariusz; Muszyńska, Magdalena; Nawrocki, Jacek

    2017-03-01

    This paper presents a robotic test stand for the ultrasonic transmission tomography (UTT) inspection of stator vane thickness. The article presents the method of the test stand design in Autodesk Robot Structural Analysis Professional 2013 software suite. The performance of the designed test stand solution was simulated in the RobotStudio software suite. The operating principle of the test stand measurement system is presented with a specific focus on the measurement strategy. The results of actual wall thickness measurements performed on stator vanes are presented.

  11. High-voltage terminal test of a test stand for a 1-MV electrostatic accelerator

    NASA Astrophysics Data System (ADS)

    Park, Sae-Hoon; Kim, Yu-Seok

    2015-10-01

    The Korea Multipurpose Accelerator Complex has been developing a 300-kV test stand for a 1-MV electrostatic accelerator ion source. The ion source and accelerating tube will be installed in a high-pressure vessel. The ion source in the high-pressure vessel is required to have a high reliability. The test stand has been proposed and developed to confirm the stable operating conditions of the ion source. The ion source will be tested at the test stand to verify the long-time operating conditions. The test stand comprises a 300-kV high-voltage terminal, a battery for the ion-source power, a 60-Hz inverter, 200-MHz radio-frequency power supply, a 5-kV extraction power supply, a 300-kV accelerating tube, and a vacuum system. The results of the 300-kV high-voltage terminal tests are presented in this paper.

  12. 2016 update of the PRIDE database and its related tools

    PubMed Central

    Vizcaíno, Juan Antonio; Csordas, Attila; del-Toro, Noemi; Dianes, José A.; Griss, Johannes; Lavidas, Ilias; Mayer, Gerhard; Perez-Riverol, Yasset; Reisinger, Florian; Ternent, Tobias; Xu, Qing-Wei; Wang, Rui; Hermjakob, Henning

    2016-01-01

    The PRoteomics IDEntifications (PRIDE) database is one of the world-leading data repositories of mass spectrometry (MS)-based proteomics data. Since the beginning of 2014, PRIDE Archive (http://www.ebi.ac.uk/pride/archive/) is the new PRIDE archival system, replacing the original PRIDE database. Here we summarize the developments in PRIDE resources and related tools since the previous update manuscript in the Database Issue in 2013. PRIDE Archive constitutes a complete redevelopment of the original PRIDE, comprising a new storage backend, data submission system and web interface, among other components. PRIDE Archive supports the most-widely used PSI (Proteomics Standards Initiative) data standard formats (mzML and mzIdentML) and implements the data requirements and guidelines of the ProteomeXchange Consortium. The wide adoption of ProteomeXchange within the community has triggered an unprecedented increase in the number of submitted data sets (around 150 data sets per month). We outline some statistics on the current PRIDE Archive data contents. We also report on the status of the PRIDE related stand-alone tools: PRIDE Inspector, PRIDE Converter 2 and the ProteomeXchange submission tool. Finally, we will give a brief update on the resources under development ‘PRIDE Cluster’ and ‘PRIDE Proteomes’, which provide a complementary view and quality-scored information of the peptide and protein identification data available in PRIDE Archive. PMID:26527722

  13. RP1 (KEROSENE) STORAGE TANKS ON HILLSIDE EAST OF TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    RP1 (KEROSENE) STORAGE TANKS ON HILLSIDE EAST OF TEST STAND 1-B. THIS TANK FARM SERVES BOTH TEST STANDS 1-A AND 1-B - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Combined Fuel Storage Tank Farm, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  14. 7. CABLE RACK, MEZZANINE LEVEL, INTERIOR OF TEST STAND 1A. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. CABLE RACK, MEZZANINE LEVEL, INTERIOR OF TEST STAND 1A. Looking north from north end of the cable tunnel leading toward Control Center. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  15. 4. COMPLETE X15 VEHICLE TEST STAND, DETAIL OF THRUST MOUNTING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. COMPLETE X-15 VEHICLE TEST STAND, DETAIL OF THRUST MOUNTING STRUCTURE AT ENGINE END OF PLANE. - Edwards Air Force Base, X-15 Engine Test Complex, Rocket Engine & Complete X-15 Vehicle Test Stands, Rogers Dry Lake, east of runway between North Base & South Base, Boron, Kern County, CA

  16. 2. ROCKET ENGINE TEST STAND, SHOWING TANK (BUILDING 1929) AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. ROCKET ENGINE TEST STAND, SHOWING TANK (BUILDING 1929) AND GARAGE (BUILDING 1930) AT LEFT REAR. Looking to west. - Edwards Air Force Base, X-15 Engine Test Complex, Rocket Engine & Complete X-15 Vehicle Test Stands, Rogers Dry Lake, east of runway between North Base & South Base, Boron, Kern County, CA

  17. Rapid HIV testing experience at Veterans Affairs North Texas Health Care System's Homeless Stand Downs.

    PubMed

    Hooshyar, Dina; Surís, Alina M; Czarnogorski, Maggie; Lepage, James P; Bedimo, Roger; North, Carol S

    2014-01-01

    In the USA, 21% of the estimated 1.1 million people living with human immunodeficiency virus/acquired immune deficiency syndrome (HIV/AIDS) are unaware they are HIV-infected. In 2011, Veterans Health Administration (VHA)'s Office of Public Health in conjunction with VHA's Health Care for Homeless Veterans Program funded grants to support rapid HIV testing at homeless outreach events because homeless populations are more likely to obtain emergent rather than preventive care and have a higher HIV seroprevalence as compared to the general population. Because of a Veterans Affairs North Texas Health Care System (VANTHCS)'s laboratory testing requirement, VANTHCS partnered with community agencies to offer rapid HIV testing for the first time at VANTHCS' 2011 Homeless Stand Downs in Dallas, Fort Worth, and Texoma, Texas. Homeless Stand Downs are outreach events that connect Veterans with services. Veterans who declined testing were asked their reasons for declining. Comparisons by Homeless Stand Down site used Pearson χ², substituting Fisher's Exact tests for expected cell sizes <5. Of the 910 Veterans attending the Homeless Stand Downs, 261 Veterans reported reasons for declining HIV testing, and 133 Veterans were tested, where 92% of the tested Veterans obtained their test results at the events - all tested negative. Veterans' reported reasons for declining HIV testing included previous negative result (n=168), no time to test (n=49), no risk factors (n=36), testing is not a priority (n=11), uninterested in knowing serostatus (n=6), and HIV-infected (n=3). Only "no time to test" differed significantly by Homeless Stand Down site. Nonresponse rate was 54%. Offering rapid HIV testing at Homeless Stand Downs is a promising testing venue since 15% of Veterans attending VANTHCS' Homeless Stand Downs were tested for HIV, and majority obtained their HIV test results at point-of-care while further research is needed to determine how to improve these rates.

  18. 7. BUILDING 604F, INTERIOR OF BULL PEN SHOWING TESTING STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. BUILDING 604-F, INTERIOR OF BULL PEN SHOWING TESTING STAND AND HEAVY WOOD LINING ON CONCRETE WALLS. STEEL PLATE ABOVE TEST STAND DEFLECTS SHRAPNEL, SCREEN FURTHER HELPS TO CONTAIN PARTICLES. ONLY SMALL EXPLOSIVES WERE TESTED HERE (GRENADES, MINES, BOMB FUZES, ETC.). - Picatinny Arsenal, 600 Area, Test Areas District, State Route 15 near I-80, Dover, Morris County, NJ

  19. Engineers conduct key water test for A-3 stand

    NASA Technical Reports Server (NTRS)

    2009-01-01

    Water cascades from the A-2 Test Stand at Stennis Space Center as engineers challenge the limits of the high-pressure water system as part of the preparation process for the A-3 Test Stand under construction. Jeff Henderson, test director for Stennis' A Complex, led a series of tests Nov. 16-20, flowing water simultaneously on the A-1 and A-2 stands, followed by the A-1 and B-1 stands, to determine if the high-pressure industrial water facility pumps and the existing pipe system can support the needs of the A-3 stand. The stand is being built to test rocket engines that will carry astronauts beyond low-Earth orbit and will need about 300,000 gallons of water per minute when operating, but the Stennis system never had been tested to that level. The recent tests were successful in showing the water facility pumps can operate at that capacity - reaching 318,000 gallons per minute in one instance. However, officials continue to analyze data to determine if the system can provide the necessary pressure at that capacity and if the delivery system piping is adequate. 'We just think if there's a problem, it's better to identify and address it now rather than when A-3 is finished and it has to be dealt with,' Henderson said.

  20. NEARING THE END OF CONSTRUCTION ON THE LOX TEST STAND AT MSFC.

    NASA Image and Video Library

    2015-01-08

    AS THE END OF CONSTRUCTION ON TEST STAND 4697, THE LIQUID OXYGEN TANK TEST STAND AT MARSHALL SPACE FLIGHT CENTER, PROJECT ENGINEERS PHIL HENDRIX, FROM MSFC, AND CURTNEY WALTERS FROM THE U.S. CORP OF ENGINEERS, STUDY PLANS AND PROGRESS.

  1. 44. HISTORIC VIEW LOOKING WEST AT THE TEST STAND AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. HISTORIC VIEW LOOKING WEST AT THE TEST STAND AND ROCKET BEING PREPARED FOR TESTING. NOTE THE LOAD CELL APPARATUS ABOVE THE ROCKET AND THE EQUIPMENT PLATFORM TO THE LEFT OF THE LOAD CELL HAVE BEEN ENCLOSED FOR PROTECTION FROM THE CLIMATE. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  2. 36. HISTORIC GENERAL VIEW LOOKING NORTH DOWN THE FLAME TRENCH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. HISTORIC GENERAL VIEW LOOKING NORTH DOWN THE FLAME TRENCH AT THE TEST STAND. NOTE THE MOTORIZED LIFT TO THE LEFT OF THE TEST STAND, USED TO ACCESS THE INSTRUMENTATION PLATFORM ('BIRDCAGE') MOUNTED ON TOP OF THE ROCKET DURING TEST FIRINGS. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  3. Saturn Apollo Program

    NASA Image and Video Library

    1967-01-01

    This photograph is a view of the Saturn V S-IC (first) test stage being hoisted into the S-IC-B1 test stand at the Mississippi Test Facility (MTF), Bay St. Louis, Mississippi. This stage was used to prove the operational readiness of the stand. Begirning operations in 1966, the MTF has two test stands; a dual-position structure for running the S-IC stage at full throttle, and two separate stands for the S-II (Saturn V third) stage. It became the focus of the static test firing program. The completed S-IC stage was shipped from the Michoud Assembly Facility (MAF) to the MTF. The stage was then installed into the 124-meter-high test stand for static firing tests before shipment to the Kennedy Space Center for final assembly of the Saturn V vehicle. The MTF was renamed to the National Space Technology Laboratory (NSTL) in 1974 and later to the Stennis Space Center (SSC) in May 1988.

  4. Credit WCT. Photographic copy of photograph, view of Test Stand ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit WCT. Photographic copy of photograph, view of Test Stand "D" from the south with tower ejector system in operation during a 1972 engine test. Note steam evolving from Z-stage ejectors atop the interstage condenser in the tower. Note also the "Hyprox" steam generator straddling the Dd ejector train to the right. The new Dy horizontal train has not been erected as of this date. In the distance is Test Stand "E." (JPL negative no. 384-9766-AC, 28 November 1972) - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  5. TEST STAND 4697 CONSTRUCTION

    NASA Image and Video Library

    2016-01-06

    A CRANE MOVES THE FIRST STEEL TIER TO BE BOLTED INTO PLACE ON JAN. 6, FOR WELDING OF A SECOND NEW STRUCTURAL TEST STAND AT NASA'S MARSHALL SPACE FLIGHT CENTER IN HUNTSVILLE, ALABAMA -- CRITICAL TO DEVELOPMENT OF NASA'S SPACE LAUNCH SYSTEM. WHEN COMPLETED THIS SUMMER, THE 85-FOOT-TALL TEST STAND 4697 WILL USE HYDRAULIC CYLINDERS TO SUBJECT THE LIQUID OXYGEN TANK AND HARDWARE OF THE MASSIVE SLS CORE STAGE TO THE SAME LOADS AND STRESSES IT WILL ENDURE DURING A LAUNCH. THE STAND IS RISING IN MARSHALL'S WEST TEST AREA, WHERE WORK IS ALSO UNDERWAY ON THE 215-FOOT-TALL TOWERS OF TEST STAND 4693, WHICH WILL CONDUCT SIMILAR STRUCTURAL TESTS ON THE SLS CORE STAGE'S LIQUID HYDROGEN TANK. SLS, THE MOST POWERFUL ROCKET EVER BUILT, WILL CARRY ASTRONAUTS IN NASA'S ORION SPACECRAFT ON DEEP SPACE MISSIONS, INCLUDING THE JOURNEY TO MARS.

  6. TMS delivered for A-3 Test Stand

    NASA Image and Video Library

    2010-03-17

    A state-of-the-art thrust measurement system for the A-3 Test Stand under construction at NASA's John C. Stennis Space Center was delivered March 17. Once completed, the A-3 stand (seen in background) will allow simulated high-altitude testing on the next generation of rocket engines for America's space program. Work on the stand began in 2007, with activation scheduled for 2012. The stand is the first major test structure to be built at Stennis since the 1960s. The recently delivered TMS was fabricated by Thrust Measurement Systems in Illinois. It is an advanced calibration system capable of measuring vertical and horizontal thrust loads with an accuracy within 0.15 percent at 225,000 pounds.

  7. Credit BG. View west of Test Stand "D" complex, with ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit BG. View west of Test Stand "D" complex, with ends of Dd (left) and Dy (right) station ejectors in view. Steam piping from accumulator (sphere) to ejectors is apparent; long horizontal loops in the pipes permit expansion and contraction without special joints. The small platform straddling the Dd ejector (near the accumulator) was originally constructed for a "Hyprox" steam generator which supplied steam to the Dd ejector before the accumulator and Dy stand were built. Note ejectors on top of interstage condenser in Test Stand "D" tower. Metal shed in far right background is for storage - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  8. Around Marshall

    NASA Image and Video Library

    1963-02-04

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This photograph taken February 4, 1963, gives an impressive look at the Block House looking directly through the ever-growing four towers of the S-IC Test Stand.

  9. SSC_NASA Tests Upgraded Water System for the B-2 Test Stand - Highlights with Music

    NASA Image and Video Library

    2017-12-04

    On December 4, Stennis Space Center conducted a water flow test on the B-2 test stand to check the water system’s upgraded modifications in preparation for Space Launch System’s Core Stage testing. During a test, rocket engine fire and exhaust is redirected out of the stand by a large flame trench. For this test, the water deluge system, with the capability of flowing 335,000 gallons of water per minute, directed more than 240,000 gallons of water per minute through more than 32,000 5/32-inch holes in the B2 stand flame deflector, cooling the exhaust and protecting the trench from damage.

  10. NASA Tests Upgraded Water System for Stennis Space Center's B-2 Test Stand

    NASA Image and Video Library

    2017-12-04

    On December 4, Stennis Space Center conducted a water flow test on the B-2 test stand to check the water system’s upgraded modifications in preparation for Space Launch System’s Core Stage testing. During a test, rocket engine fire and exhaust is redirected out of the stand by a large flame trench. For this test, the water deluge system, with the capability of flowing 335,000 gallons of water per minute, directed more than 240,000 gallons of water per minute through more than 32,000 5/32-inch holes in the B2 stand flame deflector, cooling the exhaust and protecting the trench from damage.

  11. Saturn Apollo Program

    NASA Image and Video Library

    1963-12-05

    The test laboratory of the Marshall Space Flight Center (MSFC) tested the F-1 engine, the most powerful rocket engine ever fired at MSFC. The engine was tested on the newly modified Saturn IB Static Test Stand which had been used for three years to test the Saturn I eight-engine booster, S-I (first) stage. In 1961 the test stand was modified to permit static firing of the S-I/S-IB stage and the name of the stand was then changed to the S-IB Static Test Stand. Producing a combined thrust of 7,500,000 pounds, five F-1 engines powered the S-IC (first) stage of the Saturn V vehicle for the marned lunar mission.

  12. Saturn Apollo Program

    NASA Image and Video Library

    1963-12-01

    The test laboratory of the Marshall Space Flight Center (MSFC) tested the F-1 engine, the most powerful rocket engine ever fired at MSFC. The engine was tested on the newly modified Saturn IB static test stand that had been used for three years to test the Saturn I eight-engine booster, S-I (first) stage. In 1961, the test stand was modified to permit static firing of the S-I/S-IB stage and the name of the stand was then changed to the S-IB Static Test Stand. Producing a combined thrust of 7,500,000 pounds, five F-1 engines powered the S-IC (first) stage of the Saturn V vehicle for the marned lunar mission.

  13. Shake test results of the MDHC test stand in the 40- by 80-foot wind tunnel

    NASA Technical Reports Server (NTRS)

    Lau, Benton H.; Peterson, Randall

    1994-01-01

    A shake test was conducted to determine the modal properties of the MDHC (McDonnell Douglas Helicopter Company) test stand installed in the 40- by 80- Foot Wind Tunnel at Ames Research Center. The shake test was conducted for three wind-tunnel balance configurations with and without balance dampers, and with the snubber engagement to lock the balance frame. A hydraulic shaker was used to apply random excitation at the rotor hub in the longitudinal and lateral directions. A GenRad 2515 computer-aided test system computed the frequency response functions at the rotor hub and support struts. From these response functions, the modal properties, including the natural frequency, damping ratio, and mode shape were calculated. The critical modes with low damping ratios are identified as the test-stand second longitudinal mode for the dampers-off configuration, the test-stand yaw mode for the dampers-on configuration, and the test stand first longitudinal mode for the balance-frame locked configuration.

  14. Around Marshall

    NASA Image and Video Library

    1976-01-06

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was originally designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage. Modifications to the S-IC Test Stand began in 1975 to accommodate space shuttle external tank testing. This photo is of the horizontal liquid oxygen tanks.

  15. 9. Credit JPL. Photographic copy of drawing, engineering drawing showing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Credit JPL. Photographic copy of drawing, engineering drawing showing structure of Test Stand 'A' (Building 4202/E-3) and its relationship to the Monitor Building or blockhouse (Building 4203/E-4) when a reinforced concrete machinery room was added to the west side of Test Stand 'A' in 1955. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering 'Electrical Layout - Muroc, Test Stand & Refrigeration Equipment Room,' drawing no. E3/7-0, April 6, 1955. - Jet Propulsion Laboratory Edwards Facility, Test Stand A, Edwards Air Force Base, Boron, Kern County, CA

  16. CSG delivery and installation

    NASA Image and Video Library

    2010-10-27

    John C. Stennis Space Center employees complete installation of a chemical steam generator (CSG) unit at the site's E-2 Test Stand. On Oct. 24, 2010. The unit will undergo verification and validation testing on the E-2 stand before it is moved to the A-3 Test Stand under construction at Stennis. Each CSG unit includes three modules. Steam generated by the nine CSG units that will be installed on the A-3 stand will create a vacuum that allows Stennis operators to test next-generation rocket engines at simulated altitudes up to 100,000 feet.

  17. CSG delivery and installation

    NASA Image and Video Library

    2010-10-27

    The first of nine chemical steam generator (CSG) units that will be used on the A-3 Test Stand is prepared for installation Oct. 24, 2010, at John C. Stennis Space Center. The unit was installed at the E-2 Test Stand for verification and validation testing before it is moved to the A-3 stand. Steam generated by the nine CSG units that will be installed on the A-3 stand will create a vacuum that allows Stennis operators to test next-generation rocket engines at simulated altitudes up to 100,000 feet.

  18. CSG delivery and installation

    NASA Image and Video Library

    2010-10-22

    The first of nine chemical steam generator (CSG) units that will be used on the A-3 Test Stand arrived at John. C. Stennis Space Center on Oct. 22, 2010. The unit was installed at the E-2 Test Stand for verification and validation testing before it is moved to the A-3 stand. Steam generated by the nine CSG units that will be installed on the A-3 stand will create a vacuum that allows Stennis operators to test next-generation rocket engines at simulated altitudes up to 100,000 feet.

  19. 11. "NIGHT SCENE OF TEST AREA WITH TEST STAND 1A ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. "NIGHT SCENE OF TEST AREA WITH TEST STAND 1-A IN FOREGROUND. LIGHTS OF MAIN BASE, EDWARDS AFB, IN THE BACKGROUND. EDWARDS AFB." Test Area 1-120. Looking west past Test Stand 1-A to Test Area 1-115 and Test Area 1-110. Photo no. "12,401 57; G-AFFTC 12 DEC 57; TS 1-A Aux #1". - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA

  20. Diagnosing Postural Tachycardia Syndrome: Comparison of Tilt Test versus Standing Hemodynamics

    PubMed Central

    Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R

    2012-01-01

    Postural tachycardia syndrome (POTS) is characterized by increased heart rate (ΔHR) of ≥30 bpm with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of TILT and STAND testing. ΔHR values were analyzed at 5 min intervals. Receiver Operating Characteristics analysis was performed to determine optimal cut point values of ΔHR for both TILT and STAND. TILT produced larger ΔHR than STAND for all 5 min intervals from 5 min (38±3 bpm vs. 33±3 bpm; P=0.03) to 30 min (51±3 bpm vs. 38±3 bpm; P<0.001). Sensitivity (Sn) of the 30 bpm criterion was similar for all tests (TILT-10=93%, STAND-10=87%, TILT30=100%, and STAND30=93%). Specificity (Sp) of the 30 bpm criterion was less at both 10 and 30 min for TILT (TILT10=40%, TILT30=20%) than STAND (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for TILT (with lower specificity for POTS diagnosis) than STAND at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min TILT. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used. PMID:22931296

  1. Diagnosing postural tachycardia syndrome: comparison of tilt testing compared with standing haemodynamics.

    PubMed

    Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R

    2013-01-01

    POTS (postural tachycardia syndrome) is characterized by an increased heart rate (ΔHR) of ≥30 bpm (beats/min) with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of tilt and stand testing. ΔHR values were analysed at 5 min intervals. ROC (receiver operating characteristic) analysis was performed to determine optimal cut point values of ΔHR for both tilt and stand. Tilt produced larger ΔHR than stand for all 5 min intervals from 5 min (38±3 bpm compared with 33±3 bpm; P=0.03) to 30 min (51±3 bpm compared with 38±3 bpm; P<0.001). Sn (sensitivity) of the 30 bpm criterion was similar for all tests (TILT10=93%, STAND10=87%, TILT30=100%, and STAND30=93%). Sp (specificity) of the 30 bpm criterion was less at both 10 and 30 min for tilt (TILT10=40%, TILT30=20%) than stand (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for tilt (with lower Sp for POTS diagnosis) than stand at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min tilt. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used.

  2. Adaptation Guidance for Evidence-Based Teen Pregnancy and STI/HIV Prevention Curricula: From Development to Practice

    ERIC Educational Resources Information Center

    Rolleri, Lori A.; Fuller, Taleria R.; Firpo-Triplett, Regina; Lesesne, Catherine A.; Moore, Claire; Leeks, Kimberly D.

    2014-01-01

    Evidence-based interventions (EBIs) are effective in preventing adolescent pregnancy and sexually transmitted infections; however, prevention practitioners are challenged when selecting and adapting the most appropriate programs. While there are existing adaptation frameworks, there is little practical guidance in applying research in the field.…

  3. A Structural and Correlational Analysis of Two Common Measures of Personal Epistemology

    ERIC Educational Resources Information Center

    Laster, Bonnie Bost

    2010-01-01

    Scope and Method of Study: The current inquiry is a factor analytic study which utilizes first and second order factor analytic methods to examine the internal structures of two measurements of personal epistemological beliefs: the Schommer Epistemological Questionnaire (SEQ) and Epistemic Belief Inventory (EBI). The study also examines the…

  4. Sound Speed and Attenuation in Multiphase Media

    DTIC Science & Technology

    2009-01-01

    100 to 300 m/s for sandy sediments with porosities of 40-50%. Hastrup [13:121-127] reports empirical relationships that relative speed ratios 1.0 ≤ cb...Eby, "Acoustic attenuation in a liquid layer over a "slow" viscoelastic solid", J. Acoust. Soc. Amer. 3496), 836-843, 1962 [13] O. F. Hastrup

  5. HMMER web server: 2018 update.

    PubMed

    Potter, Simon C; Luciani, Aurélien; Eddy, Sean R; Park, Youngmi; Lopez, Rodrigo; Finn, Robert D

    2018-06-14

    The HMMER webserver [http://www.ebi.ac.uk/Tools/hmmer] is a free-to-use service which provides fast searches against widely used sequence databases and profile hidden Markov model (HMM) libraries using the HMMER software suite (http://hmmer.org). The results of a sequence search may be summarized in a number of ways, allowing users to view and filter the significant hits by domain architecture or taxonomy. For large scale usage, we provide an application programmatic interface (API) which has been expanded in scope, such that all result presentations are available via both HTML and API. Furthermore, we have refactored our JavaScript visualization library to provide standalone components for different result representations. These consume the aforementioned API and can be integrated into third-party websites. The range of databases that can be searched against has been expanded, adding four sequence datasets (12 in total) and one profile HMM library (6 in total). To help users explore the biological context of their results, and to discover new data resources, search results are now supplemented with cross references to other EMBL-EBI databases.

  6. The DNA Data Bank of Japan launches a new resource, the DDBJ Omics Archive of functional genomics experiments.

    PubMed

    Kodama, Yuichi; Mashima, Jun; Kaminuma, Eli; Gojobori, Takashi; Ogasawara, Osamu; Takagi, Toshihisa; Okubo, Kousaku; Nakamura, Yasukazu

    2012-01-01

    The DNA Data Bank of Japan (DDBJ; http://www.ddbj.nig.ac.jp) maintains and provides archival, retrieval and analytical resources for biological information. The central DDBJ resource consists of public, open-access nucleotide sequence databases including raw sequence reads, assembly information and functional annotation. Database content is exchanged with EBI and NCBI within the framework of the International Nucleotide Sequence Database Collaboration (INSDC). In 2011, DDBJ launched two new resources: the 'DDBJ Omics Archive' (DOR; http://trace.ddbj.nig.ac.jp/dor) and BioProject (http://trace.ddbj.nig.ac.jp/bioproject). DOR is an archival database of functional genomics data generated by microarray and highly parallel new generation sequencers. Data are exchanged between the ArrayExpress at EBI and DOR in the common MAGE-TAB format. BioProject provides an organizational framework to access metadata about research projects and the data from the projects that are deposited into different databases. In this article, we describe major changes and improvements introduced to the DDBJ services, and the launch of two new resources: DOR and BioProject.

  7. Text processing through Web services: calling Whatizit.

    PubMed

    Rebholz-Schuhmann, Dietrich; Arregui, Miguel; Gaudan, Sylvain; Kirsch, Harald; Jimeno, Antonio

    2008-01-15

    Text-mining (TM) solutions are developing into efficient services to researchers in the biomedical research community. Such solutions have to scale with the growing number and size of resources (e.g. available controlled vocabularies), with the amount of literature to be processed (e.g. about 17 million documents in PubMed) and with the demands of the user community (e.g. different methods for fact extraction). These demands motivated the development of a server-based solution for literature analysis. Whatizit is a suite of modules that analyse text for contained information, e.g. any scientific publication or Medline abstracts. Special modules identify terms and then link them to the corresponding entries in bioinformatics databases such as UniProtKb/Swiss-Prot data entries and gene ontology concepts. Other modules identify a set of selected annotation types like the set produced by the EBIMed analysis pipeline for proteins. In the case of Medline abstracts, Whatizit offers access to EBI's in-house installation via PMID or term query. For large quantities of the user's own text, the server can be operated in a streaming mode (http://www.ebi.ac.uk/webservices/whatizit).

  8. Evaluating and optimizing horticultural regimes in space plant growth facilities

    NASA Technical Reports Server (NTRS)

    Berkovich, Y. A.; Chetirkin, P. V.; Wheeler, R. M.; Sager, J. C.

    2004-01-01

    In designing innovative space plant growth facilities (SPGF) for long duration space flight, various limitations must be addressed including onboard resources: volume, energy consumption, heat transfer and crew labor expenditure. The required accuracy in evaluating on board resources by using the equivalent mass methodology and applying it to the design of such facilities is not precise. This is due to the uncertainty of the structure and not completely understanding the properties of all associated hardware, including the technology in these systems. We present a simple criteria of optimization for horticultural regimes in SPGF: Qmax = max [M x (EBI)2/(V x E x T], where M is the crop harvest in terms of total dry biomass in the plant growth system; EBI is the edible biomass index (harvest index), V is volume occupied by the crop; E is the crop light energy supply during growth; T is the crop growth duration. The criterion reflects directly on the consumption of onboard resources for crop production. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

  9. The MIntAct project—IntAct as a common curation platform for 11 molecular interaction databases

    PubMed Central

    Orchard, Sandra; Ammari, Mais; Aranda, Bruno; Breuza, Lionel; Briganti, Leonardo; Broackes-Carter, Fiona; Campbell, Nancy H.; Chavali, Gayatri; Chen, Carol; del-Toro, Noemi; Duesbury, Margaret; Dumousseau, Marine; Galeota, Eugenia; Hinz, Ursula; Iannuccelli, Marta; Jagannathan, Sruthi; Jimenez, Rafael; Khadake, Jyoti; Lagreid, Astrid; Licata, Luana; Lovering, Ruth C.; Meldal, Birgit; Melidoni, Anna N.; Milagros, Mila; Peluso, Daniele; Perfetto, Livia; Porras, Pablo; Raghunath, Arathi; Ricard-Blum, Sylvie; Roechert, Bernd; Stutz, Andre; Tognolli, Michael; van Roey, Kim; Cesareni, Gianni; Hermjakob, Henning

    2014-01-01

    IntAct (freely available at http://www.ebi.ac.uk/intact) is an open-source, open data molecular interaction database populated by data either curated from the literature or from direct data depositions. IntAct has developed a sophisticated web-based curation tool, capable of supporting both IMEx- and MIMIx-level curation. This tool is now utilized by multiple additional curation teams, all of whom annotate data directly into the IntAct database. Members of the IntAct team supply appropriate levels of training, perform quality control on entries and take responsibility for long-term data maintenance. Recently, the MINT and IntAct databases decided to merge their separate efforts to make optimal use of limited developer resources and maximize the curation output. All data manually curated by the MINT curators have been moved into the IntAct database at EMBL-EBI and are merged with the existing IntAct dataset. Both IntAct and MINT are active contributors to the IMEx consortium (http://www.imexconsortium.org). PMID:24234451

  10. E-MSD: an integrated data resource for bioinformatics.

    PubMed

    Golovin, A; Oldfield, T J; Tate, J G; Velankar, S; Barton, G J; Boutselakis, H; Dimitropoulos, D; Fillon, J; Hussain, A; Ionides, J M C; John, M; Keller, P A; Krissinel, E; McNeil, P; Naim, A; Newman, R; Pajon, A; Pineda, J; Rachedi, A; Copeland, J; Sitnov, A; Sobhany, S; Suarez-Uruena, A; Swaminathan, G J; Tagari, M; Tromm, S; Vranken, W; Henrick, K

    2004-01-01

    The Macromolecular Structure Database (MSD) group (http://www.ebi.ac.uk/msd/) continues to enhance the quality and consistency of macromolecular structure data in the Protein Data Bank (PDB) and to work towards the integration of various bioinformatics data resources. We have implemented a simple form-based interface that allows users to query the MSD directly. The MSD 'atlas pages' show all of the information in the MSD for a particular PDB entry. The group has designed new search interfaces aimed at specific areas of interest, such as the environment of ligands and the secondary structures of proteins. We have also implemented a novel search interface that begins to integrate separate MSD search services in a single graphical tool. We have worked closely with collaborators to build a new visualization tool that can present both structure and sequence data in a unified interface, and this data viewer is now used throughout the MSD services for the visualization and presentation of search results. Examples showcasing the functionality and power of these tools are available from tutorial webpages (http://www. ebi.ac.uk/msd-srv/docs/roadshow_tutorial/).

  11. E-MSD: an integrated data resource for bioinformatics

    PubMed Central

    Golovin, A.; Oldfield, T. J.; Tate, J. G.; Velankar, S.; Barton, G. J.; Boutselakis, H.; Dimitropoulos, D.; Fillon, J.; Hussain, A.; Ionides, J. M. C.; John, M.; Keller, P. A.; Krissinel, E.; McNeil, P.; Naim, A.; Newman, R.; Pajon, A.; Pineda, J.; Rachedi, A.; Copeland, J.; Sitnov, A.; Sobhany, S.; Suarez-Uruena, A.; Swaminathan, G. J.; Tagari, M.; Tromm, S.; Vranken, W.; Henrick, K.

    2004-01-01

    The Macromolecular Structure Database (MSD) group (http://www.ebi.ac.uk/msd/) continues to enhance the quality and consistency of macromolecular structure data in the Protein Data Bank (PDB) and to work towards the integration of various bioinformatics data resources. We have implemented a simple form-based interface that allows users to query the MSD directly. The MSD ‘atlas pages’ show all of the information in the MSD for a particular PDB entry. The group has designed new search interfaces aimed at specific areas of interest, such as the environment of ligands and the secondary structures of proteins. We have also implemented a novel search interface that begins to integrate separate MSD search services in a single graphical tool. We have worked closely with collaborators to build a new visualization tool that can present both structure and sequence data in a unified interface, and this data viewer is now used throughout the MSD services for the visualization and presentation of search results. Examples showcasing the functionality and power of these tools are available from tutorial webpages (http://www.ebi.ac.uk/msd-srv/docs/roadshow_tutorial/). PMID:14681397

  12. A Call to Develop Evidence-based Interventions to Reduce Sexually Transmitted Infections in Juvenile Justice Populations.

    PubMed

    Gates, Madison L; Staples-Horne, Michelle; Cartier, Jeanne; Best, Candace; Stone, Rebecca; Walker, Veronica; Hastings, Beverly; Yoo, Wonsuk; Webb, Nancy C; Braithwaite, Ronald L

    2016-01-01

    Sexually transmitted infections (STIs), including human immunodeficiency virus (HIV) risk, are a significant health issue for young women (ages 16-21), especially African Americans with a juvenile justice history. Studies have found that 44% of young African American women have had at least one STI compared to 24.1% for all young women. The rate of STIs among young women with juvenile justice histories, particularly African Americans, is likely much higher than their non-detained peers. Yet, there are few evidence-based interventions (EBIs) designed specifically for the detained population. In 2014, the Centers for Disease Control and Prevention's Compendium of Evidence-Based Interventions and Best Practices for HIV Prevention listed few programs that comprehensively included components related to mental health, intimate relationships and high risk sexual behaviors that would be salient for a detained population. Further, many EBIs have had limited or no long-term protective effect. We propose that interrelated factors (mental health, substance use, trauma and intimate relationships) can effectively decrease risk and increase protective behaviors for the detained population most at risk.

  13. A hollow cathode ion source for production of primary ions for the BNL electron beam ion source.

    PubMed

    Alessi, James; Beebe, Edward; Carlson, Charles; McCafferty, Daniel; Pikin, Alexander; Ritter, John

    2014-02-01

    A hollow cathode ion source, based on one developed at Saclay, has been modified significantly and used for several years to produce all primary 1+ ions injected into the Relativistic Heavy Ion Collider Electron Beam Ion Source (EBIS) at Brookhaven. Currents of tens to hundreds of microamperes have been produced for 1+ ions of He, C, O, Ne, Si, Ar, Ti, Fe, Cu, Kr, Xe, Ta, Au, and U. The source is very simple, relying on a glow discharge using a noble gas, between anode and a solid cathode containing the desired species. Ions of both the working gas and ionized sputtered cathode material are extracted, and then the desired species is selected using an ExB filter before being transported into the EBIS trap for charge breeding. The source operates pulsed with long life and excellent stability for most species. Reliable ignition of the discharge at low gas pressure is facilitated by the use of capacitive coupling from a simple toy plasma globe. The source design, and operating experience for the various species, is presented.

  14. The EMBL nucleotide sequence database

    PubMed Central

    Stoesser, Guenter; Baker, Wendy; van den Broek, Alexandra; Camon, Evelyn; Garcia-Pastor, Maria; Kanz, Carola; Kulikova, Tamara; Lombard, Vincent; Lopez, Rodrigo; Parkinson, Helen; Redaschi, Nicole; Sterk, Peter; Stoehr, Peter; Tuli, Mary Ann

    2001-01-01

    The EMBL Nucleotide Sequence Database (http://www.ebi.ac.uk/embl/) is maintained at the European Bioinformatics Institute (EBI) in an international collaboration with the DNA Data Bank of Japan (DDBJ) and GenBank at the NCBI (USA). Data is exchanged amongst the collaborating databases on a daily basis. The major contributors to the EMBL database are individual authors and genome project groups. Webin is the preferred web-based submission system for individual submitters, whilst automatic procedures allow incorporation of sequence data from large-scale genome sequencing centres and from the European Patent Office (EPO). Database releases are produced quarterly. Network services allow free access to the most up-to-date data collection via ftp, email and World Wide Web interfaces. EBI’s Sequence Retrieval System (SRS), a network browser for databanks in molecular biology, integrates and links the main nucleotide and protein databases plus many specialized databases. For sequence similarity searching a variety of tools (e.g. Blitz, Fasta, BLAST) are available which allow external users to compare their own sequences against the latest data in the EMBL Nucleotide Sequence Database and SWISS-PROT. PMID:11125039

  15. "Boring" family routines reduce non-communicable diseases: a commentary and call for action.

    PubMed

    Rotheram-Borus, Mary Jane; Tomlinson, Mark; Davis, Emily

    2015-01-01

    As global donors shift their efforts from infectious diseases to non-communicable diseases (NCD), it is critical to capitalize on our prior mistakes and successes. Policy makers and public health administrators are often looking for magic bullets: drugs or treatments to eradicate disease. Yet, each potential magic bullet requires consistent, daily implementation and adherence to a new set of habits to actually work. Families' and communities' daily, interlocking routines will be the battlefield on which scientific and technological breakthroughs will be implemented and succeed or not. Currently, there are many evidence-based interventions (EBI) which have been demonstrated to shift specific habits which account for most NCD (eating, drinking, moving, and smoking). Yet, securing sustained uptake of these programs is rare - suggesting different intervention strategies are needed. Structural changes, policy nudges, and partnerships with private enterprise may be able to shift the health behaviors of more citizens faster and at a lower cost than existing EBI. Addressing concurrent risk and protective factors at the community level and intervening to shape new cultural routines may be useful to reduce NCD.

  16. Kinetic energy offsets for multicharged ions from an electron beam ion source.

    PubMed

    Kulkarni, D D; Ahl, C D; Shore, A M; Miller, A J; Harriss, J E; Sosolik, C E; Marler, J P

    2017-08-01

    Using a retarding field analyzer, we have measured offsets between the nominal and measured kinetic energy of multicharged ions extracted from an electron beam ion source (EBIS). By varying source parameters, a shift in ion kinetic energy was attributed to the trapping potential produced by the space charge of the electron beam within the EBIS. The space charge of the electron beam depends on its charge density, which in turn depends on the amount of negative charge (electron beam current) and its velocity (electron beam energy). The electron beam current and electron beam energy were both varied to obtain electron beams of varying space charge and these were related to the observed kinetic energy offsets for Ar 4+ and Ar 8+ ion beams. Knowledge of these offsets is important for studies that seek to utilize slow, i.e., low kinetic energy, multicharged ions to exploit their high potential energies for processes such as surface modification. In addition, we show that these offsets can be utilized to estimate the effective radius of the electron beam inside the trap.

  17. Provider Perspectives on Evidence-Based HIV Prevention Interventions: Barriers and Facilitators to Implementation

    PubMed Central

    Dickson-Gomez, Julia

    2011-01-01

    Abstract Since the beginning of the HIV/AIDS epidemic, community-based organizations (CBOs) have been key players in combating this disease through grassroots prevention programs and close ties to at-risk populations. Increasingly, both funding agencies and public health institutions require that CBOs implement evidence-based HIV prevention interventions, most of which are researcher developed. However, after completing training for these evidence-based interventions (EBIs), agencies may either abandon plans to implement them or significantly modify the intervention. Based on 22 semistructured interviews with HIV prevention service providers, this article explores the barriers and facilitators to dissemination and implementation of EBIs included in the Centers for Disease Control and Prevention's (CDC) Diffusion of Effective Behavioral Interventions (DEBI) program. Results suggest that there is a tension between the need to implement interventions with fidelity and the lack of guidance on how to adapt the interventions for their constituencies and organizational contexts. Findings suggest the need for HIV prevention intervention development and dissemination that integrate community partners in all phases of research and dissemination. PMID:21323564

  18. EDAM: an ontology of bioinformatics operations, types of data and identifiers, topics and formats

    PubMed Central

    Ison, Jon; Kalaš, Matúš; Jonassen, Inge; Bolser, Dan; Uludag, Mahmut; McWilliam, Hamish; Malone, James; Lopez, Rodrigo; Pettifer, Steve; Rice, Peter

    2013-01-01

    Motivation: Advancing the search, publication and integration of bioinformatics tools and resources demands consistent machine-understandable descriptions. A comprehensive ontology allowing such descriptions is therefore required. Results: EDAM is an ontology of bioinformatics operations (tool or workflow functions), types of data and identifiers, application domains and data formats. EDAM supports semantic annotation of diverse entities such as Web services, databases, programmatic libraries, standalone tools, interactive applications, data schemas, datasets and publications within bioinformatics. EDAM applies to organizing and finding suitable tools and data and to automating their integration into complex applications or workflows. It includes over 2200 defined concepts and has successfully been used for annotations and implementations. Availability: The latest stable version of EDAM is available in OWL format from http://edamontology.org/EDAM.owl and in OBO format from http://edamontology.org/EDAM.obo. It can be viewed online at the NCBO BioPortal and the EBI Ontology Lookup Service. For documentation and license please refer to http://edamontology.org. This article describes version 1.2 available at http://edamontology.org/EDAM_1.2.owl. Contact: jison@ebi.ac.uk PMID:23479348

  19. Around Marshall

    NASA Image and Video Library

    1962-10-26

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This construction photo, taken October 26, 1962, depicts a view of the Block House tunnel opening.

  20. Around Marshall

    NASA Image and Video Library

    1962-08-17

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This construction photo taken August 17, 1962 depicts a back side view of the Block House.

  1. Around Marshall

    NASA Image and Video Library

    1962-11-15

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This construction photo, taken November 15, 1962, depicts a view of the Block House.

  2. Around Marshall

    NASA Image and Video Library

    1962-01-23

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This photo, taken January 23, 1962, shows the excavation of the Block House site.

  3. Around Marshall

    NASA Image and Video Library

    1962-06-13

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. Construction of the tunnel is depicted in this photo taken June 13, 1962.

  4. Around Marshall

    NASA Image and Video Library

    1962-02-02

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This photo, taken February 2, 1962, shows the excavation of the Block House site.

  5. 49. HISTORIC GENERAL VIEW LOOKING NORTHWEST AT THE TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    49. HISTORIC GENERAL VIEW LOOKING NORTHWEST AT THE TEST STAND IN ITS CONFIGURATION FOR THE MERCURY-REDSTONE TESTING PROGRAM. NOTE THE MERCURY CAPSULE BEING ASSEMBLED IN THE FOREGROUND, ALSO NOTE THE LOAD CELL APPARATUS ON THE GROUND IN THE RIGHT OF THE PHOTOGRAPH. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  6. Credit BG. View looking west down into Test Stand "D" ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit BG. View looking west down into Test Stand "D" vertical vacuum cell with top removed. Access to cell is normally through large round port seen in view. Piping and cradling toward bottom of cell was last used in tests of Viking space probe engines - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  7. Validation of Cardiovascular Parameters During NASA's Functional Task Test

    NASA Technical Reports Server (NTRS)

    Arzeno, N. M.; Stenger, M. B.; Bloomberg, J. J.; Platts, Steven H.

    2008-01-01

    Microgravity-induced physiological changes, including cardiovascular deconditioning may impair crewmembers f capabilities during exploration missions on the Moon and Mars. The Functional Task Test (FTT), which will be used to assess task performance in short and long duration astronauts, consists of 7 functional tests to evaluate crewmembers f ability to perform activities to be conducted in a partial-gravity environment or following an emergency landing on Earth. The Recovery from Fall/Stand Test (RFST) tests both the subject fs ability to get up from a prone position and orthostatic intolerance. PURPOSE: Crewmembers have never become presyncopal in the first 3 min of quiet stand, yet it is unknown whether 3 min is long enough to cause similar heart rate fluctuations to a 5-min stand. The purpose of this study was to validate and test the reliability of heart rate variability (HRV) analysis of a 3-min quiet stand. METHODS: To determine the validity of using 3 vs. 5-min of standing to assess HRV, 7 healthy subjects remained in a prone position for 2 min, stood up quickly and stood quietly for 6 min. ECG and continuous blood pressure data were recorded. Mean R-R interval and spectral HRV were measured in minutes 0-3 and 0-5 following the heart rate transient due to standing. Significant differences between the segments were determined by a paired t-test. To determine the reliability of the 3-min stand test, 13 healthy subjects completed 3 trials of the complete FTT on separate days, including the RFST with a 3-min stand test. Analysis of variance (ANOVA) was performed on the HRV measures. RESULTS: Spectral HRV measures reflecting autonomic activity were not different (p>0.05) during the 0-3 and 0-5 min segment (mean R-R interval: 738+/-74 ms, 728+/-69 ms; low frequency to high frequency ratio: 6.5+/-2.2, 7.7+/-2.7; normalized high frequency: 0.19+/-0.03, 0.18+/-0.04). The average coefficient of variation for mean R-R interval, systolic and diastolic blood pressures in the prone position and stand test were less than 8% for the test sessions. ANOVA results yielded a greater inter-subject variability (p.0.006) than inter-session variability (p>0.05) for HRV in the stand test. CONCLUSION: These studies show that a 3 minute stand delivers repeatable cardiovascular heart rate and BP data in the context of this larger series of tests such as the FTT.

  8. 4. Credit BG. View looking northeast at west facade of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Credit BG. View looking northeast at west facade of Test Stand 'E' 4259/E-60, solid rocket motor test facility. Wooden barricades to north and south of 4259/E-60 protect personnel and other facilities from flying debris in case of inadvertent explosions. Test Stand 'E' is accessed from the tunnel system by the inclined tube shown at the center of the image adjacent to a ladder. Racks running to the north (having the appearance of a low fence) carry electrical cables to Test Stand 'G' (Building 4271/E-72). - Jet Propulsion Laboratory Edwards Facility, Test Stand E, Edwards Air Force Base, Boron, Kern County, CA

  9. 40 CFR 63.9350 - What reports must I submit and when?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands... reconstructed engine test cell/stand that is subject to permitting regulations pursuant to 40 CFR part 70 or 71... reconstructed engine test cell/stand during the reporting period. (3) A summary of the total duration of the...

  10. 40 CFR 63.9345 - What notifications must I submit and when?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands... apply to you by the dates specified. (b) If you own or operate a new or reconstructed test cell/stand... engine test cell/stand has no additional requirements and explain the basis of the exclusion (for example...

  11. 40 CFR 63.9345 - What notifications must I submit and when?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands... apply to you by the dates specified. (b) If you own or operate a new or reconstructed test cell/stand... engine test cell/stand has no additional requirements and explain the basis of the exclusion (for example...

  12. 40 CFR 63.9350 - What reports must I submit and when?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands... reconstructed engine test cell/stand that is subject to permitting regulations pursuant to 40 CFR part 70 or 71... reconstructed engine test cell/stand during the reporting period. (3) A summary of the total duration of the...

  13. 40 CFR 63.9350 - What reports must I submit and when?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands... reconstructed engine test cell/stand that is subject to permitting regulations pursuant to 40 CFR part 70 or 71... reconstructed engine test cell/stand during the reporting period. (3) A summary of the total duration of the...

  14. 49 CFR 655.5 - Stand-down waivers for drug testing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Stand-down waivers for drug testing. 655.5 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PREVENTION OF ALCOHOL MISUSE AND PROHIBITED DRUG USE IN TRANSIT OPERATIONS General § 655.5 Stand-down waivers for drug testing. (a) An employer subject to this part may...

  15. 49 CFR 655.5 - Stand-down waivers for drug testing.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Stand-down waivers for drug testing. 655.5 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PREVENTION OF ALCOHOL MISUSE AND PROHIBITED DRUG USE IN TRANSIT OPERATIONS General § 655.5 Stand-down waivers for drug testing. (a) An employer subject to this part may...

  16. 49 CFR 655.5 - Stand-down waivers for drug testing.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Stand-down waivers for drug testing. 655.5 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PREVENTION OF ALCOHOL MISUSE AND PROHIBITED DRUG USE IN TRANSIT OPERATIONS General § 655.5 Stand-down waivers for drug testing. (a) An employer subject to this part may...

  17. 49 CFR 655.5 - Stand-down waivers for drug testing.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Stand-down waivers for drug testing. 655.5 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PREVENTION OF ALCOHOL MISUSE AND PROHIBITED DRUG USE IN TRANSIT OPERATIONS General § 655.5 Stand-down waivers for drug testing. (a) An employer subject to this part may...

  18. 49 CFR 655.5 - Stand-down waivers for drug testing.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Stand-down waivers for drug testing. 655.5 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PREVENTION OF ALCOHOL MISUSE AND PROHIBITED DRUG USE IN TRANSIT OPERATIONS General § 655.5 Stand-down waivers for drug testing. (a) An employer subject to this part may...

  19. 40 CFR 63.9345 - What notifications must I submit and when?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands... apply to you by the dates specified. (b) If you own or operate a new or reconstructed test cell/stand... engine test cell/stand has no additional requirements and explain the basis of the exclusion (for example...

  20. 40 CFR 63.9350 - What reports must I submit and when?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands... reconstructed engine test cell/stand that is subject to permitting regulations pursuant to 40 CFR part 70 or 71... reconstructed engine test cell/stand during the reporting period. (3) A summary of the total duration of the...

  1. 40 CFR 63.9345 - What notifications must I submit and when?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands... apply to you by the dates specified. (b) If you own or operate a new or reconstructed test cell/stand... engine test cell/stand has no additional requirements and explain the basis of the exclusion (for example...

  2. 40 CFR 63.9306 - What are my continuous parameter monitoring system (CPMS) installation, operation, and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Standards for Hazardous Air Pollutants for Engine Test Cells/Stands General Compliane Requirements § 63.9306... at all times that an engine test cell/stand is operating, except during monitoring malfunctions... engine test cell/stand is operating. You must inspect the automatic shutdown system at least once every...

  3. 40 CFR 63.9306 - What are my continuous parameter monitoring system (CPMS) installation, operation, and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Standards for Hazardous Air Pollutants for Engine Test Cells/Stands General Compliane Requirements § 63.9306... at all times that an engine test cell/stand is operating, except during monitoring malfunctions... engine test cell/stand is operating. You must inspect the automatic shutdown system at least once every...

  4. 39. HISTORIC VIEW LOOKING WEST AT THE TEST STAND WITH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    39. HISTORIC VIEW LOOKING WEST AT THE TEST STAND WITH THE COLD CALIBRATION TOWER CONSTRUCTED TO THE LEFT OF THE ROCKET AND AN ACCESS PLATFORM BUILT TO REACH THE TOP OF THE ROCKET MORE EASILY. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  5. 1. BUILDING 8698, TEST STAND 13, WEST ELEVATION. NOTE TUNNEL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. BUILDING 8698, TEST STAND 1-3, WEST ELEVATION. NOTE TUNNEL BETWEEN BLDG. 8668 AND TEST STAND 1-3. TEST AREA 1-120 IN THE MIDDLE DISTANCE, AND TEST AREA 1-125 ON THE HORIZON. Looking northeast from the roof of Building 8668, Instrumentation and Control Center. Note: Photograph CA-236-F-2 is an 8" x 10" enlargement from a 4" x 5" negative. This view is a photocopy of a recent resin coated print made from a print held at the Main Base History Office, Edwards Air Force Base, California. Photographer unknown. Date and file number unknown. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  6. IL-27 Production and STAT3-Dependent Upregulation of B7-H1 Mediate Immune Regulatory Functions of Liver Plasmacytoid DC1

    PubMed Central

    Matta, Benjamin M.; Raimondi, Giorgio; Rosborough, Brian R.; Sumpter, Tina L.; Thomson, Angus W.

    2012-01-01

    Plasmacytoid (p) dendritic cells (DC) are highly-specialized APC that, in addition to their well-recognized role in anti-viral immunity, also regulate immune responses. Liver-resident pDC are considerably less immunostimulatory than those from secondary lymphoid tissues and are equipped to promote immune tolerance/regulation through various mechanisms. IL-27 is an IL-12-family cytokine that regulates the function of both APC and T cells, although little is known about its role in pDC immunobiology. In this study, we show that mouse liver pDC express higher levels of IL-27p28 and EBV-induced protein (Ebi)3 compared to splenic pDC. Both populations of pDC express the IL-27Rα/WSX-1; however, only liver pDC significantly upregulate expression of the co-regulatory molecule B7 homolog-1 (B7-H1) in response to IL-27. Inhibition of STAT3 activation completely abrogates IL-27-induced upregulation of B7-H1 expression on liver pDC. Liver pDC treated with IL-27 increase the percentage of CD4+Foxp3+ T cells in MLR, which is dependent upon expression of B7-H1. pDC from Ebi3-deficient mice lacking functional IL-27, show increased capacity to stimulate allogeneic T cell proliferation and IFN-γ production in MLR. Liver but not spleen pDC suppress delayed-type hypersensitivity responses to OVA, an effect that is lost with Ebi3−/− and B7-H1−/− liver pDC compared to wild-type (WT) liver pDC. These data suggest that IL-27 signaling in pDC promotes their immunoregulatory function and that IL-27 produced by pDC contributes to their capacity to regulate immuneresponses in vitro and in vivo. PMID:22508931

  7. SOX2 and SOX2-MYC Reprogramming Process of Fibroblasts to the Neural Stem Cells Compromised by Senescence

    PubMed Central

    Winiecka-Klimek, Marta; Smolarz, Maciej; Walczak, Maciej P.; Zieba, Jolanta; Hulas-Bigoszewska, Krystyna; Kmieciak, Blazej; Piaskowski, Sylwester; Rieske, Piotr; Grzela, Dawid P.; Stoczynska-Fidelus, Ewelina

    2015-01-01

    Tumorigenic potential of induced pluripotent stem cells (iPSCs) infiltrating population of induced neural stem cells (iNSCs) generated from iPSCs may limit their medical applications. To overcome such a difficulty, direct reprogramming of adult somatic cells into iNSCs was proposed. The aim of this study was the systematic comparison of induced neural cells (iNc) obtained with different methods—direct reprogramming of human adult fibroblasts with either SOX2 (SiNSc-like) or SOX2 and c-MYC (SMiNSc-like) and induced pluripotent stem cells differentiation to ebiNSc—in terms of gene expression profile, differentiation potential as well as proliferation properties. Immunocytochemistry and real-time PCR analyses were used to evaluate gene expression profile and differentiation potential of various iNc types. Bromodeoxyuridine (BrdU) incorporation and senescence-associated beta-galactosidase (SA-β-gal) assays were used to estimate proliferation potential. All three types of iNc were capable of neuronal differentiation; however, astrocytic differentiation was possible only in case of ebiNSc. Contrary to ebiNSc generation, the direct reprogramming was rarely a propitious process, despite 100% transduction efficiency. The potency of direct iNSCs-like cells generation was lower as compared to iNSCs obtained by iPSCs differentiation, and only slightly improved when c-MYC was added. Directly reprogrammed iNSCs-like cells were lacking the ability to differentiate into astrocytic cells and characterized by poor efficiency of neuronal cells formation. Such features indicated that these cells could not be fully reprogrammed, as confirmed mainly with senescence detection. Importantly, SiNSc-like and SMiNSc-like cells were unable to achieve the long-term survival and became senescent, which limits their possible therapeutic applicability. Our results suggest that iNSCs-like cells, generated in the direct reprogramming attempts, were either not fully reprogrammed or reprogrammed only into neuronal progenitors, mainly because of the inaccuracies of currently available protocols. PMID:26535892

  8. Optimal Threshold Determination for Interpreting Semantic Similarity and Particularity: Application to the Comparison of Gene Sets and Metabolic Pathways Using GO and ChEBI

    PubMed Central

    Bettembourg, Charles; Diot, Christian; Dameron, Olivier

    2015-01-01

    Background The analysis of gene annotations referencing back to Gene Ontology plays an important role in the interpretation of high-throughput experiments results. This analysis typically involves semantic similarity and particularity measures that quantify the importance of the Gene Ontology annotations. However, there is currently no sound method supporting the interpretation of the similarity and particularity values in order to determine whether two genes are similar or whether one gene has some significant particular function. Interpretation is frequently based either on an implicit threshold, or an arbitrary one (typically 0.5). Here we investigate a method for determining thresholds supporting the interpretation of the results of a semantic comparison. Results We propose a method for determining the optimal similarity threshold by minimizing the proportions of false-positive and false-negative similarity matches. We compared the distributions of the similarity values of pairs of similar genes and pairs of non-similar genes. These comparisons were performed separately for all three branches of the Gene Ontology. In all situations, we found overlap between the similar and the non-similar distributions, indicating that some similar genes had a similarity value lower than the similarity value of some non-similar genes. We then extend this method to the semantic particularity measure and to a similarity measure applied to the ChEBI ontology. Thresholds were evaluated over the whole HomoloGene database. For each group of homologous genes, we computed all the similarity and particularity values between pairs of genes. Finally, we focused on the PPAR multigene family to show that the similarity and particularity patterns obtained with our thresholds were better at discriminating orthologs and paralogs than those obtained using default thresholds. Conclusion We developed a method for determining optimal semantic similarity and particularity thresholds. We applied this method on the GO and ChEBI ontologies. Qualitative analysis using the thresholds on the PPAR multigene family yielded biologically-relevant patterns. PMID:26230274

  9. Around Marshall

    NASA Image and Video Library

    1963-09-18

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. This photograph taken September 18, 1963 shows a spherical hydrogen tank being constructed next to the S-IC test stand.

  10. Comparison of Test Stand and Helicopter Oil Cooler Bearing Condition Indicators

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Branning, Jeremy; Wade, Damiel R.; Bolander, Nathan

    2010-01-01

    The focus of this paper was to compare the performance of HUMS condition indicators (CI) when detecting a bearing fault in a test stand or on a helicopter. This study compared data from two sources: first, CI data collected from accelerometers installed on two UH-60 Black Hawk helicopters when oil cooler bearing faults occurred, along with data from helicopters with no bearing faults; and second, CI data that was collected from ten cooler bearings, healthy and faulted, that were removed from fielded helicopters and installed in a test stand. A method using Receiver Operating Characteristic (ROC) curves to compare CI performance was demonstrated. Results indicated the bearing energy CI responded differently for the helicopter and the test stand. Future research is required if test stand data is to be used validate condition indicator performance on a helicopter.

  11. Around Marshall

    NASA Image and Video Library

    1993-09-01

    Marshall Space Flight Center's F-1 Engine Test Stand is shown in this picture. Constructed in 1963, the test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability is provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. The foundation of the stand is keyed into the bedrock approximately 40 feet below grade.

  12. A-1 Test Stand work

    NASA Technical Reports Server (NTRS)

    2010-01-01

    A structural steel beam to support the new thrust measurement system on the A-1 Test Stand at NASA's John C. Stennis Space Center is lifted to waiting employees for installation. The beam is part of the thrust takeout structure needed to support the new measurement system. Four such beams have been installed at the stand in preparation for installation of the system in upcoming weeks. Operators are preparing the stand for testing the next generation of rocket engines for the U.S. space program.

  13. [Reliability of static posturography in elderly persons].

    PubMed

    Bauer, C M; Gröger, I; Rupprecht, R; Tibesku, C O; Gassmann, K G

    2010-08-01

    Static posturography is used to quantify body sway. It is used to assess the balance of elderly persons who are prone to falls. There is still no general opinion concerning the reliability of force platform measurements. The aim of this study was to test the reliability of force platform parameters when measuring elderly persons. The reliability of 11 force platform parameters was tested measuring 30 elderly persons. The following parameters were calculated: mean speed of center of pressure displacement in mm/s, length of sway in mm, sway area in mm(2), amplitudes of center of pressure movement, the axis of oscillation in degrees and the person's angles of inclination in degrees. Three measurements were taken on the same day, with a resting period of 2 min. Four different test conditions were used: normal standing and narrow stand with eyes open and eyes closed, respectively. Reliability was determined by using intraclass correlation coefficients. Six parameters had excellent reliability with a correlation coefficient of >0.9: mean speed of center of pressure movement during narrow stand, area of sway during narrow stand, length of sway during normal and narrow stand, and the angle of inclination in the sagittal plane during normal stand and narrow stand. The condition "narrow stand eyes closed" proved to be the most reliable test position. Six parameters proved to have excellent reliability and are recommended to be used in further investigations. Narrow stand with eyes closed should be used as the test position. The tested protocol proved to be reliable. Whether these parameters can be used to predict falls in elderly persons remains to be investigated.

  14. VIEW OF EAST TEST SITE FROM TOP OF STATIC TEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF EAST TEST SITE FROM TOP OF STATIC TEST TOWER VIEW INCLUDES STRUCTURAL DYNAMICS TEST STAND COLD CALIBRATION TEST STAND AND COMPONENTS TEST LAB. - Marshall Space Flight Center, East Test Area, Dodd Road, Huntsville, Madison County, AL

  15. 26. "TEST STAND, STRUCTURAL, FOUNDATION PLAN." Specifications No. ENG043535572; Drawing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. "TEST STAND, STRUCTURAL, FOUNDATION PLAN." Specifications No. ENG-04-353-55-72; Drawing No. 60-0912; sheet 25 of 148; file no. 1320/76. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  16. 7. COMPLETE X15 VEHICLE TEST STAND AFTER AN ENGINE FIRE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. COMPLETE X-15 VEHICLE TEST STAND AFTER AN ENGINE FIRE OR EXPLOSION. Wreckage of engine is still fixed in its clamp; X-15 vehicle lies on the ground detached from engine. - Edwards Air Force Base, X-15 Engine Test Complex, Rocket Engine & Complete X-15 Vehicle Test Stands, Rogers Dry Lake, east of runway between North Base & South Base, Boron, Kern County, CA

  17. 2. TEST AREA 1115, A VIEW TO THE SOUTHEAST FROM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. TEST AREA 1-115, A VIEW TO THE SOUTHEAST FROM THE DECK OF TEST STAND 1-5. AT RIGHT IS BUILDING 8642, MACHINE SHOP FOR TEST STAND 1-5. AT LEFT IS BUILDING 8649, AND PART OF BUILDING 8647, TEST STAND 1-4, IS VISIBLE TO LEFT OF BLDG. 8649. (PANORAMA 1/2). - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA

  18. Developments in Test Facility and Data Networking for the Altitude Test Stand at the John C. Stennis Space Center: A General Overview

    NASA Technical Reports Server (NTRS)

    Hebert, Phillip W.

    2008-01-01

    NASA/SSC's Mission in Rocket Propulsion Testing Is to Acquire Test Performance Data for Verification, Validation and Qualification of Propulsion Systems Hardware: Accurate, Reliable, Comprehensive, and Timely. Data Acquisition in a Rocket Propulsion Test Environment Is Challenging: a) Severe Temporal Transient Dynamic Environments; b) Large Thermal Gradients; c) Vacuum to high pressure regimes. A-3 Test Stand Development is equally challenging with respect to accommodating vacuum environment, operation of a CSG system, and a large quantity of data system and control channels to determine proper engine performance as well as Test Stand operation. SSC is currently in the process of providing modernized DAS, Control Systems, Video, and network systems for the A-3 Test Stand to overcome these challenges.

  19. Space Shuttle Projects

    NASA Image and Video Library

    1978-09-01

    Workmen in the Dynamic Test Stand lowered the nose cone into place to complete stacking of the left side of the solid rocket booster (SRB) in the Dynamic Test Stand at the east test area of the Marshall Space Flight Center (MSFC). The SRB would be attached to the external tank (ET) and then the orbiter later for the Mated Vertical Ground Vibration Test (MVGVT), that resumed in October 1978. The stacking of a complete Shuttle in the Dynamic Test Stand allowed test engineers to perform ground vibration testing on the Shuttle in its liftoff configuration. The purpose of the MVGVT was to verify that the Space Shuttle would perform as predicted during launch. The platforms inside the Dynamic Test Stand were modified to accommodate two SRB'S to which the ET was attached.

  20. 7. MOTION PICTURE CAMERA STAND AT BUILDING 8768. Edwards ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. MOTION PICTURE CAMERA STAND AT BUILDING 8768. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunkers for Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  1. Using a Virtual Environment to Deliver Evidence-Based Interventions: The Facilitator's Experience

    PubMed Central

    Villarruel, Antonia; Tschannen, Dana; Valladares, Angel; Yaksich, Joseph; Yeagley, Emily; Hawes, Armani

    2015-01-01

    Background Evidence-based interventions (EBIs) have the potential to maximize positive impact on communities. However, despite the quantity and quality of EBIs for prevention, the need for formalized training and associated training-related expenses, such as travel costs, program materials, and input of personnel hours, pose implementation challenges for many community-based organizations. In this study, the community of inquiry (CoI) framework was used to develop the virtual learning environment to support the adaptation of the ¡Cuídate! (Take Care of Yourself!) Training of Facilitators curriculum (an EBI) to train facilitators from community-based organizations. Objective The purpose of this study was to examine the feasibility of adapting a traditional face-to-face facilitator training program for ¡Cuídate!, a sexual risk reduction EBI for Latino youth, for use in a multi-user virtual environment (MUVE). Additionally, two aims of the study were explored: the acceptability of the facilitator training and the level of the facilitators’ knowledge and self-efficacy to implement the training. Methods A total of 35 facilitators were trained in the virtual environment. We evaluated the facilitators' experience in the virtual training environment and determined if the learning environment was acceptable and supported the acquisition of learning outcomes. To this end, the facilitators were surveyed using a modified community of inquiry survey, with questions specific to the Second Life environment and an open-ended questionnaire. In addition, a comparison to face-to-face training was conducted using survey methods. Results Results of the community of inquiry survey demonstrated a subscale mean of 23.11 (SD 4.12) out of a possible 30 on social presence, a subscale mean of 8.74 (SD 1.01) out of a possible 10 on teaching presence, and a subscale mean of 16.69 (SD 1.97) out of a possible 20 on cognitive presence. The comparison to face-to-face training showed no significant differences in participants' ability to respond to challenging or sensitive questions (P=.50) or their ability to help participants recognize how Latino culture supports safer sex (P=.32). There was a significant difference in their knowledge of core elements and modules (P<.001). A total of 74% (26/35) of the Second Life participants did agree/strongly agree that they had the skills to deliver the ¡Cuídate! program. Conclusions The results showed that participants found the Second Life environment to be acceptable to the learners and supported an experience in which learners were able to acquire the knowledge and skills needed to deliver the curriculum. PMID:26199045

  2. 8. Credit JPL. Photographic copy of photograph, view west down ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Credit JPL. Photographic copy of photograph, view west down from Test Stand 'A' tower across newly installed tunnel tube to corner of Building 4201/E-2, Test Stand 'A' Workshop (demolished in 1985). Note the wooden retaining structure erected in the foreground to retain earth once the tunnel trench is backfilled (this retaining wall remained in 1994). Note also the propellant control piping on the Test Stand 'A' platform in the immediate foreground. (JPL negative no. 384-1547-C, 6 February 1957) - Jet Propulsion Laboratory Edwards Facility, Test Stand A, Edwards Air Force Base, Boron, Kern County, CA

  3. Pathfinder

    NASA Image and Video Library

    1997-06-04

    This shot offers a bird's eye-view of a Fastrac II engine duration test at Marshall's Test Stand 116. The Fastrac II engine was designed as a part of the low cost X-34 Reusable Launch Vehicle (RLV). The purpose for these tests was to test the different types of metal alloys in the nozzle. Beside the engine were six additional nozzels which spray a continuous stream of water onto the test stand to reduce damage to the test stand and the engines. The X-34 program was cancelled in 2001.

  4. Interleukin-27 is a novel candidate diagnostic biomarker for bacterial infection in critically ill children.

    PubMed

    Wong, Hector R; Cvijanovich, Natalie Z; Hall, Mark; Allen, Geoffrey L; Thomas, Neal J; Freishtat, Robert J; Anas, Nick; Meyer, Keith; Checchia, Paul A; Lin, Richard; Bigham, Michael T; Sen, Anita; Nowak, Jeffrey; Quasney, Michael; Henricksen, Jared W; Chopra, Arun; Banschbach, Sharon; Beckman, Eileen; Harmon, Kelli; Lahni, Patrick; Shanley, Thomas P

    2012-10-29

    Differentiating between sterile inflammation and bacterial infection in critically ill patients with fever and other signs of the systemic inflammatory response syndrome (SIRS) remains a clinical challenge. The objective of our study was to mine an existing genome-wide expression database for the discovery of candidate diagnostic biomarkers to predict the presence of bacterial infection in critically ill children. Genome-wide expression data were compared between patients with SIRS having negative bacterial cultures (n = 21) and patients with sepsis having positive bacterial cultures (n = 60). Differentially expressed genes were subjected to a leave-one-out cross-validation (LOOCV) procedure to predict SIRS or sepsis classes. Serum concentrations of interleukin-27 (IL-27) and procalcitonin (PCT) were compared between 101 patients with SIRS and 130 patients with sepsis. All data represent the first 24 hours of meeting criteria for either SIRS or sepsis. Two hundred twenty one gene probes were differentially regulated between patients with SIRS and patients with sepsis. The LOOCV procedure correctly predicted 86% of the SIRS and sepsis classes, and Epstein-Barr virus-induced gene 3 (EBI3) had the highest predictive strength. Computer-assisted image analyses of gene-expression mosaics were able to predict infection with a specificity of 90% and a positive predictive value of 94%. Because EBI3 is a subunit of the heterodimeric cytokine, IL-27, we tested the ability of serum IL-27 protein concentrations to predict infection. At a cut-point value of ≥5 ng/ml, serum IL-27 protein concentrations predicted infection with a specificity and a positive predictive value of >90%, and the overall performance of IL-27 was generally better than that of PCT. A decision tree combining IL-27 and PCT improved overall predictive capacity compared with that of either biomarker alone. Genome-wide expression analysis has provided the foundation for the identification of IL-27 as a novel candidate diagnostic biomarker for predicting bacterial infection in critically ill children. Additional studies will be required to test further the diagnostic performance of IL-27. The microarray data reported in this article have been deposited in the Gene Expression Omnibus under accession number GSE4607.

  5. Investigation of postural hypotension due to static prolonged standing in female workers.

    PubMed

    Kabe, Isamu; Tsuruoka, Hiroko; Tokujitani, Yoko; Endo, Yuichi; Furusawa, Mami; Takebayashi, Toru

    2007-07-01

    The "Just-in-Time system" improves productivity and efficiency through cost reduction while it makes workers work in a standing posture. The aim of this study was to investigate the prevalence of postural hypotension in females during prolonged standing work, and to discuss preventive methods. Twelve female static standing workers (mean age+/-standard deviation; 32+/-14 yr old), 6 male static standing workers (30+/-4 yr old), 10 female walking workers (27+/-7 yr old) and 9 female desk workers (31+/-5 yr old) in a certain telecommunications equipment manufacturing factory agreed to participate in this study. All participants received an interview with an occupational physician, and performed the standing up test before working and ambulatory blood pressure monitoring (ABPM) while working. Although the blood pressure of the standing up test did not differ among the groups, mean pulse rates on standing up significantly increased in every group. Hypotension rates in the female standing workers' group by ABPM were 9 persons of 12 participants (75%) for systolic blood pressure (SBP), and were 11 persons of 12 participants (92%) for diastolic blood pressure (DBP). There were significantly higher than those in the female desk workers' group, none of 9 participants (0%) for SBP and 2 of 9 participants (22%) for DBP. The hypotension rates both male standing and female walking worker groups did not differ. Because all 8 workers who were found to have postural hypotension by the standing up test had decreased SBP and/or DBP by ABPM, it is suggested that persons at high risk of postural hypotension during standing work could be screened by the standing up test. The mechanism of postural hypotension may be a decrease of venous return due to leg swelling, and neurocardiogenic or vasovagal response. Preventing the congestion of the lower limbs by walking, managing standing time and wearing elastic hose to keep the amount of the venous return could prevent postural hypotension during prolonged standing work.

  6. 1. Photographic copy of engineering drawing showing elevations and sections ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Photographic copy of engineering drawing showing elevations and sections of Test Stand 'E' (Building 4259/E-60). California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering 'Solid Propellant Test Stand E-60 - Elevations & Sections,' sheet E60/10, no date. - Jet Propulsion Laboratory Edwards Facility, Test Stand E, Edwards Air Force Base, Boron, Kern County, CA

  7. 4. Credit WCT. Photographic copy of photograph, test Stand 'B' ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Credit WCT. Photographic copy of photograph, test Stand 'B' set up for shock tube and research on ship-to-ship fueling problems for the U.S. Coast Guard. (JPL negative no. 344-3743-A, October or November 1980) - Jet Propulsion Laboratory Edwards Facility, Test Stand B, Edwards Air Force Base, Boron, Kern County, CA

  8. Around Marshall

    NASA Image and Video Library

    1962-03-31

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow tunnel which housed the cables for the controls. Again to the east, just south of the Block House, was a newly constructed Pump House. Its function was to provide water to the stand to prevent melting damage during testing. The water was sprayed through small holes in the stand’s 1900 ton water deflector at the rate of 320,000 gallons per minute. In this photo, taken March 20, 1962, construction of the Pump House area is well underway.

  9. Around Marshall

    NASA Image and Video Library

    1963-08-12

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built to the east was a newly constructed Pump House. Its function was to provide water to the stand to prevent melting damage during testing. The water was sprayed through small holes in the stand’s 1900 ton flame deflector at the rate of 320,000 gallons per minute. In this photo, taken August 12, 1963, the S-IC stand has received some of its internal components. Directly in the center is the framework that houses the flame deflector. The F-1 test stand, designed and built to test a single F-1 engine, can be seen on the left side of the photo.

  10. 8. "TEST STAND, ARCHITECTURAL, FLOOR PLANS AND SCHEDULES." Specifications No. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. "TEST STAND, ARCHITECTURAL, FLOOR PLANS AND SCHEDULES." Specifications No. ENG-04-353-55-72; Drawing No. 60-0912; sheet 22 of 148; file no. 1320/73. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  11. VIEW OF EAST TEST SITE FROM TOP OF STATIC TEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF EAST TEST SITE FROM TOP OF STATIC TEST TOWER VIEW INCLUDES POWER PLANT TEST STAND AND SATURN V TEST STAND IN THE WEST TEST AREA (FAR BACKGROUND). - Marshall Space Flight Center, East Test Area, Dodd Road, Huntsville, Madison County, AL

  12. Increased Reliability for Single-Case Research Results: Is the Bootstrap the Answer?

    ERIC Educational Resources Information Center

    Parker, Richard I.

    2006-01-01

    There is need for objective and reliable single-case research (SCR) results in the movement toward evidence-based interventions (EBI), for inclusion in meta-analyses, and for funding accountability in clinical contexts. Yet SCR deals with data that often do not conform to parametric data assumptions and that yield results of low reliability. A…

  13. Physiological and Growth Characteristics of Shewanella Species

    DTIC Science & Technology

    2016-05-01

    AFCEC-CX-TY-TR-2016-0016 PHYSIOLOGICAL AND GROWTH CHARACTERISTICS OF SHEWANELLA SPECIES Karen Farrington, D. Matthew Eby, Susan Sizemore...Technical Report 01 March 2012 - 01 March 2014 Physiological and growth characteristics of Shewanella species FA4819-11-C-0003 Karen Farrington (1...unconventional operating temperatures. Secondly, the unusual growth characteristics of another Shewanella sp., Shewanella japonica, were investigated

  14. From the Laboratory to the Classroom: The Effects of Equivalence-Based Instruction on Neuroanatomy Competencies

    ERIC Educational Resources Information Center

    Fienup, Daniel M.; Mylan, Sanaa E.; Brodsky, Julia; Pytte, Carolyn

    2016-01-01

    Equivalence-based instruction (EBI) has been used to successfully teach college-level concepts in research laboratories, but few studies have examined the results of such instruction on classroom performance. The current study answered a basic question about the ordering of training stimuli as well as an applied question regarding the effects of…

  15. Childhood Brain Insult: Can Age at Insult Help Us Predict Outcome?

    ERIC Educational Resources Information Center

    Anderson, Vicki; Spencer-Smith, Megan; Leventer, Rick; Coleman, Lee; Anderson, Peter; Williams, Jackie; Greenham, Mardee; Jacobs, Rani

    2009-01-01

    Until recently, the impact of early brain insult (EBI) has been considered to be less significant than for later brain injuries, consistent with the notion that the young brain is more flexible and able to reorganize in the context of brain insult. This study aimed to evaluate this notion by comparing cognitive and behavioural outcomes for…

  16. Around Marshall

    NASA Image and Video Library

    2002-10-01

    This is a ground level view of Test Stand 500 at the east test area of the Marshall Space Flight Center. Originally constructed in 1966, Test Stand 500 is a multipurpose, dual-position test facility. The stand was utilized to test liquid hydrogen/liquid oxygen turbopumps and combustion devices for the J-2 engine. One test position has a high superstructure with lines and tankage for testing liquid hydrogen and liquid oxygen turbopumps while the other position is adaptable to pressure-fed test programs such as turbo machinery bearings or seals. The facility was modified in 1980 to support Space Shuttle main engine (SSME) bearing testing.

  17. Around Marshall

    NASA Image and Video Library

    1962-07-03

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This construction photo taken July 3, 1962 depicts the Block House with a portion of its concrete walls poured and exposed while many are still in the forms stage.

  18. 2. Photographic copy of engineering drawing showing mechanical systems in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Photographic copy of engineering drawing showing mechanical systems in plan and sections of Test Stand 'E,' including tunnel entrance. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering 'Bldg. E-60 Mechanical, Solid Propellant Test Stand,' sheet E60/13-4, June 20, 1961. - Jet Propulsion Laboratory Edwards Facility, Test Stand E, Edwards Air Force Base, Boron, Kern County, CA

  19. 2. View looking southeast at north and west facades of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. View looking southeast at north and west facades of Test Stand 'D' workshop 4222/E-23, with Test Stand 'D' tower in background and tunnel access shed to the right. Equipment on 4222/E-23 roof is for air conditioning. - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Workshop, Edwards Air Force Base, Boron, Kern County, CA

  20. 1. View looking northeast at the west and south facades ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. View looking northeast at the west and south facades of Test Stand 'D' workshop 4222/E-23. Test Stand 'D' tower nitrogen tanks, television camera platform and access stairs are at right of image. Ductwork atop roof is for air conditioning system. - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Workshop, Edwards Air Force Base, Boron, Kern County, CA

  1. Saturn Apollo Program

    NASA Image and Video Library

    1967-09-09

    This photograph depicts the F-1 engine firing in the Marshall Space Flight Center’s F-1 Engine Static Test Stand. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. It is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, designed to assist in the development of the F-1 Engine. Capability is provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. The foundation of the stand is keyed into the bedrock approximately 40 feet below grade.

  2. New Marshall Center Test Stand 4697 Construction Time-Lapse

    NASA Image and Video Library

    2016-09-27

    In less than two minutes watch structural Test Stand 4697 rise at NASA's Marshall Space Flight Center from the start of construction in May 2014 to the end of the stand's construction phase in September 2016. The stand will subject the 196,000-gallon liquid oxygen tank of the Space Launch System's massive core stage to the same stresses and pressures it must endure at launch and in flight. Now, Marshall teams are installing sophisticated fluid transfer and pressurization systems, hydraulic controls, electrical control and data systems, fiber optics cables and special test equipment to prepare for the arrival of the test tank in 2017. (NASA/MSFC/David Olive)

  3. Around Marshall

    NASA Image and Video Library

    1962-10-08

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This construction photo, taken October 8, 1962, depicts a front view of the Block House nearing completion.

  4. Photographic copy of plan of new Dy horizontal station and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of plan of new Dy horizontal station and accumulator additions to Test Stand "D," also showing existing Dd test station. JPL drawing by VTN Consolidated, Inc. Engineers, Architects, Planners, 2301 Campus Drive, Irvine, California 92664: "Jet Propulsion Laboratory-Edwards Test Station, Motive Steam Supply & Ejector Pumping System: Plan - Test Stand "D," sheet M-3 (JPL sheet number E24/33), 21 December 1976 - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  5. "Chair Stand Test" as Simple Tool for Sarcopenia Screening in Elderly Women.

    PubMed

    Pinheiro, P A; Carneiro, J A O; Coqueiro, R S; Pereira, R; Fernandes, M H

    2016-01-01

    To investigate the association between sarcopenia and "chair stand test" performance, and evaluate this test as a screening tool for sarcopenia in community-dwelling elderly women. Cross-sectional Survey. 173 female individuals, aged ≥ 60 years and living in the urban area of the municipality of Lafaiete Coutinho, Bahia's inland, Brazil. The association between sarcopenia (defined by muscle mass, strength and/or performance loss) and performance in the "chair stand test" was tested by binary logistic regression technique. The ROC curve parameters were used to evaluate the diagnostic power of the test in sarcopenia screening. The significance level was set at 5 %. The model showed that the time spent for the "chair stand test" was positively associated (OR = 1.08; 95% CI = 1.01 - 1.16, p = 0.024) to sarcopenia, indicating that, for each 1 second increment in the test performance, the sarcopenia's probability increased by 8% in elderly women. The cut-off point that showed the best balance between sensitivity and specificity was 13 seconds. The performance of "chair stand test" showed predictive ability for sarcopenia, being an effective and simple screening tool for sarcopenia in elderly women. This test could be used for screening sarcopenic elderly women, allowing early interventions.

  6. 5. "TEST STAND 13, CONCRETE STRUCTURAL SECTIONS AND DETAILS." Specifications ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. "TEST STAND 1-3, CONCRETE STRUCTURAL SECTIONS AND DETAILS." Specifications No. OC12-50-10; Drawing No. 60-09-06; no sheet number within title block. D.O. SERIES 1109/17, Rev. A. Stamped: AS BUILT; NO CHANGES. Date of Revision A: 11/1/50. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  7. Photographic copy of photograph, aerial view looking south at Jet ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of photograph, aerial view looking south at Jet Propulsion Laboratory, Edwards Test Station complex in 1959, shortly after completion of Test Stand 'D' construction and installation of underground tunnel system. Test Stand 'D' is in the foreground, Test Stand 'A' complex in the background. Roads are as yet unpaved. (JPL negative no. 384-1917-B, 28 May 1959) - Jet Propulsion Laboratory Edwards Facility, Edwards Air Force Base, Boron, Kern County, CA

  8. 12. "TEST STAND; STRUCTURAL; DEFLECTOR PIT DETAILS, SHEET NO. 1." ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. "TEST STAND; STRUCTURAL; DEFLECTOR PIT DETAILS, SHEET NO. 1." Specifications No. ENG-04-353-55-72; Drawing No. 60-09-12; sheet 41 of 148; file no. 1320/92, Rev. A. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  9. 11. "INSTRUMENTATION AND CONTROL SYSTEMS, EQUIPMENT LOCATION, TEST STAND TERMINAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. "INSTRUMENTATION AND CONTROL SYSTEMS, EQUIPMENT LOCATION, TEST STAND TERMINAL ROOM, PLANS AND SECTION." Specifications No. ENG-04-353-55-72; Drawing No. 60-0912; sheet 106 of 148; file no. 1321/57. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  10. 27. "TEST STAND; STRUCTURAL; SIDEWALL, NORTH WALL AND SOUTH WALL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. "TEST STAND; STRUCTURAL; SIDEWALL, NORTH WALL AND SOUTH WALL FRAMING ELEVATIONS." Specifications No. ENG-04353-55-72; Drawing No. 60-09-12; sheet 27 of 148; file no. 1320/78. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, Rev. B; date: 15 April 1957. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  11. 9. "TEST STAND; STRUCTURAL; CABLE TUNNEL, PLAN, SECTIONS, DETAILS." Specifications ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. "TEST STAND; STRUCTURAL; CABLE TUNNEL, PLAN, SECTIONS, DETAILS." Specifications No. OC1-55-72-(Rev.); Drawing No. 60-09-12; sheet 43 of 148; file no. AF 1320/94, Rev. A. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  12. NEO Test Stand Analysis

    NASA Technical Reports Server (NTRS)

    Pike, Cody J.

    2015-01-01

    A project within SwampWorks is building a test stand to hold regolith to study how dust is ejected when exposed to the hot exhaust plume of a rocket engine. The test stand needs to be analyzed, finalized, and fabrication drawings generated to move forward. Modifications of the test stand assembly were made with Creo 2 modeling software. Structural analysis calculations were developed by hand to confirm if the structure will hold the expected loads while optimizing support positions. These calculations when iterated through MatLab demonstrated the optimized position of the vertical support to be 98'' from the far end of the stand. All remaining deflections were shown to be under the 0.6'' requirement and internal stresses to meet NASA Ground Support Equipment (GSE) Safety Standards. Though at the time of writing, fabrication drawings have yet to be generated, but are expected shortly after.

  13. Effect of yoga training on one leg standing and functional reach tests in obese individuals with poor postural control

    PubMed Central

    Jorrakate, Chaiyong; Kongsuk, Jutaluk; Pongduang, Chiraprapa; Sadsee, Boontiwa; Chanthorn, Phatchari

    2015-01-01

    [Purpose] The aim of the present study was to investigate the effect of yoga training on static and dynamic standing balance in obese individuals with poor standing balance. [Subjects and Methods] Sixteen obese volunteers were randomly assigned into yoga and control groups. The yoga training program was performed for 45 minutes per day, 3 times per week, for 4 weeks. Static and dynamic balance were assessed in volunteers with one leg standing and functional reach tests. Outcome measures were tested before training and after a single week of training. Two-way repeated measure analysis of variance with Tukey’s honestly significant difference post hoc statistics was used to analyze the data. [Results] Obese individuals showed significantly increased static standing balance in the yoga training group, but there was no significant improvement of static or dynamic standing balance in the control group after 4 weeks. In the yoga group, significant increases in static standing balance was found after the 2nd, 3rd, and 4th weeks. Compared with the control group, static standing balance in the yoga group was significantly different after the 2nd week, and dynamic standing balance was significantly different after the 4th week. [Conclusion] Yoga training would be beneficial for improving standing balance in obese individuals with poor standing balance. PMID:25642038

  14. TARA MARSHALL AND MIKE NICHOLS AT TEST STAND 4693

    NASA Image and Video Library

    2016-12-14

    TARA MARSHALL, LEFT, A MARSHALL ENGINEER, TALKS ABOUT THE INSTALLATION OF A PRESSURIZATION CONTROL PANEL AT TEST STAND 4693 WITH MIKE NICHOLS, LEAD TEST ENGINEER FOR THE SPACE LAUNCH SYSTEM LIQUID HYDROGEN TANK STRUCTURAL TEST ARTICLE.

  15. Around Marshall

    NASA Image and Video Library

    2002-10-01

    This is a ground level view of Test Stand 300 at the east test area of the Marshall Space Flight Center. Test Stand 300 was constructed in 1964 as a gas generator and heat exchanger test facility to support the Saturn/Apollo Program. Deep-space simulation was provided by a 1960 modification that added a 20-ft thermal vacuum chamber and a 1981 modification that added a 12-ft vacuum chamber. The facility was again modified in 1989 when 3-ft and 15-ft diameter chambers were added to support Space Station and technology programs. This multiposition test stand is used to test a wide range of rocket engine components, systems, and subsystems. It has the capability to simulate launch thermal and pressure profiles. Test Stand 300 was designed for testing solid rocket booster (SRB) insulation panels and components, super-insulated tanks, external tank (ET) insulation panels and components, Space Shuttle components, solid rocket motor materials, and advanced solid rocket motor materials.

  16. Redstone Test Stand Accepted Into National Register of Historical Places

    NASA Technical Reports Server (NTRS)

    1976-01-01

    On October 02, 1976, Marshall Space Flight Center's (MSFC) Redstone test stand was received into the National Registry of Historical Places. Photographed in front of the Redstone test stand are Dr. William R. Lucas, MSFC Center Director from June 15, 1974 until July 3, 1986, as he is accepting a certificate of registration from Madison County Commission Chairman James Record, and Huntsville architect Harvie Jones.

  17. Thinning from below in a 60-year-old western white pine stand

    Treesearch

    Marvin W. Foiles

    1955-01-01

    Thirty-year results from a test of thinning a 60-year-old western white pine stand indicate that thinning does not appreciably change total volume growth, but it does improve the quality of the final product by increasing diameter growth and improving stand composition. This test was established in 1919 on the Priest River Experimental Forest, Idaho, to test three...

  18. Around Marshall

    NASA Image and Video Library

    1963-09-25

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built to the northeast of the stand was a newly constructed Pump House. Its function was to provide water to the stand to prevent melting damage during testing. The water was sprayed through small holes in the stand’s 1900 ton flame deflector at the rate of 320,000 gallons per minute. This photograph, taken September 25, 1963, depicts the construction progress of the Pump House and massive round water tanks on the right.

  19. Around Marshall

    NASA Image and Video Library

    1963-09-05

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. In the center portion of this photograph, taken September 5, 1963, the spherical hydrogen storage tanks are being constructed. One of the massive tower legs of the S-IC test stand is visible to the far right.

  20. iPhone Sensors in Tracking Outcome Variables of the 30-Second Chair Stand Test and Stair Climb Test to Evaluate Disability: Cross-Sectional Pilot Study

    PubMed Central

    Samaan, Michael A; Schultz, Brooke; Popovic, Tijana; Souza, Richard B; Majumdar, Sharmila

    2017-01-01

    Background Performance tests are important to characterize patient disabilities and functional changes. The Osteoarthritis Research Society International and others recommend the 30-second Chair Stand Test and Stair Climb Test, among others, as core tests that capture two distinct types of disability during activities of daily living. However, these two tests are limited by current protocols of testing in clinics. There is a need for an alternative that allows remote testing of functional capabilities during these tests in the osteoarthritis patient population. Objective Objectives are to (1) develop an app for testing the functionality of an iPhone’s accelerometer and gravity sensor and (2) conduct a pilot study objectively evaluating the criterion validity and test-retest reliability of outcome variables obtained from these sensors during the 30-second Chair Stand Test and Stair Climb Test. Methods An iOS app was developed with data collection capabilities from the built-in iPhone accelerometer and gravity sensor tools and linked to Google Firebase. A total of 24 subjects performed the 30-second Chair Stand Test with an iPhone accelerometer collecting data and an external rater manually counting sit-to-stand repetitions. A total of 21 subjects performed the Stair Climb Test with an iPhone gravity sensor turned on and an external rater timing the duration of the test on a stopwatch. App data from Firebase were converted into graphical data and exported into MATLAB for data filtering. Multiple iterations of a data processing algorithm were used to increase robustness and accuracy. MATLAB-generated outcome variables were compared to the manually determined outcome variables of each test. Pearson’s correlation coefficients (PCCs), Bland-Altman plots, intraclass correlation coefficients (ICCs), standard errors of measurement, and repeatability coefficients were generated to evaluate criterion validity, agreement, and test-retest reliability of iPhone sensor data against gold-standard manual measurements. Results App accelerometer data during the 30-second Chair Stand Test (PCC=.890) and gravity sensor data during the Stair Climb Test (PCC=.865) were highly correlated to gold-standard manual measurements. Greater than 95% of values on Bland-Altman plots comparing the manual data to the app data fell within the 95% limits of agreement. Strong intraclass correlation was found for trials of the 30-second Chair Stand Test (ICC=.968) and Stair Climb Test (ICC=.902). Standard errors of measurement for both tests were found to be within acceptable thresholds for MATLAB. Repeatability coefficients for the 30-second Chair Stand Test and Stair Climb Test were 0.629 and 1.20, respectively. Conclusions App-based performance testing of the 30-second Chair Stand Test and Stair Climb Test is valid and reliable, suggesting its applicability to future, larger-scale studies in the osteoarthritis patient population. PMID:29079549

Top