Sample records for ecg management system

  1. An integrated healthcare information system for end-to-end standardized exchange and homogeneous management of digital ECG formats.

    PubMed

    Trigo, Jesús Daniel; Martínez, Ignacio; Alesanco, Alvaro; Kollmann, Alexander; Escayola, Javier; Hayn, Dieter; Schreier, Günter; García, José

    2012-07-01

    This paper investigates the application of the enterprise information system (EIS) paradigm to standardized cardiovascular condition monitoring. There are many specifications in cardiology, particularly in the ECG standardization arena. The existence of ECG formats, however, does not guarantee the implementation of homogeneous, standardized solutions for ECG management. In fact, hospital management services need to cope with various ECG formats and, moreover, several different visualization applications. This heterogeneity hampers the normalization of integrated, standardized healthcare information systems, hence the need for finding an appropriate combination of ECG formats and a suitable EIS-based software architecture that enables standardized exchange and homogeneous management of ECG formats. Determining such a combination is one objective of this paper. The second aim is to design and develop the integrated healthcare information system that satisfies the requirements posed by the previous determination. The ECG formats selected include ISO/IEEE11073, Standard Communications Protocol for Computer-Assisted Electrocardiography, and an ECG ontology. The EIS-enabling techniques and technologies selected include web services, simple object access protocol, extensible markup language, or business process execution language. Such a selection ensures the standardized exchange of ECGs within, or across, healthcare information systems while providing modularity and accessibility.

  2. [Practical experience about the compatibility of PDF converter in ECG information system].

    PubMed

    Yang, Gang; Lu, Weishi; Zhou, Jiacheng

    2009-11-01

    To find a way to view ECG from different manufacturers in electrocardiogram information system. Different format ECG data were transmitted to ECG center by different ways. Corresponding analysis software was used to make the diagnosis reports in the center. Then we use PDF convert to change all ECG reports into PDF format. The electrocardiogram information system manage these PDF format ECG data for clinic user. The ECG reports form several major ECG manufacturers were transformed to PDF format successfully. In the electrocardiogram information system it is freely to view the ECG figure. PDF format ECG report is a practicable way to solve the compatibility problem in electrocardiogram information system.

  3. A system for intelligent home care ECG upload and priorisation.

    PubMed

    D'Angelo, Lorenzo T; Tarita, Eugeniu; Zywietz, Tosja K; Lueth, Tim C

    2010-01-01

    In this contribution, a system for internet based, automated home care ECG upload and priorisation is presented for the first time. It unifies the advantages of existing telemonitoring ECG systems adding functionalities such as automated priorisation and usability for home care. Chronic cardiac diseases are a big group in the geriatric field. Most of them can be easily diagnosed with help of an electrocardiogram. A frequent or long-term ECG analysis allows early diagnosis of e.g. a cardiac infarction. Nevertheless, patients often aren't willing to visit a doctor for prophylactic purposes. Possible solutions of this problem are home care devices, which are used to investigate patients at home without the presence of a doctor on site. As the diffusion of such systems leads to a huge amount of data which has to be managed and evaluated, the presented approach focuses on an easy to use software for ECG upload from home, a web based management application and an algorithm for ECG preanalysis and priorisation.

  4. Internet based ECG medical information system.

    PubMed

    James, D A; Rowlands, D; Mahnovetski, R; Channells, J; Cutmore, T

    2003-03-01

    Physiological monitoring of humans for medical applications is well established and ready to be adapted to the Internet. This paper describes the implementation of a Medical Information System (MIS-ECG system) incorporating an Internet based ECG acquisition device. Traditionally clinical monitoring of ECG is largely a labour intensive process with data being typically stored on paper. Until recently, ECG monitoring applications have also been constrained somewhat by the size of the equipment required. Today's technology enables large and fixed hospital monitoring systems to be replaced by small portable devices. With an increasing emphasis on health management a truly integrated information system for the acquisition, analysis, patient particulars and archiving is now a realistic possibility. This paper describes recent Internet and technological advances and presents the design and testing of the MIS-ECG system that utilises those advances.

  5. Object-oriented analysis and design of an ECG storage and retrieval system integrated with an HIS.

    PubMed

    Wang, C; Ohe, K; Sakurai, T; Nagase, T; Kaihara, S

    1996-03-01

    For a hospital information system, object-oriented methodology plays an increasingly important role, especially for the management of digitized data, e.g., the electrocardiogram, electroencephalogram, electromyogram, spirogram, X-ray, CT and histopathological images, which are not yet computerized in most hospitals. As a first step in an object-oriented approach to hospital information management and storing medical data in an object-oriented database, we connected electrocardiographs to a hospital network and established the integration of ECG storage and retrieval systems with a hospital information system. In this paper, the object-oriented analysis and design of the ECG storage and retrieval systems is reported.

  6. Issues in implementing a knowledge-based ECG analyzer for personal mobile health monitoring.

    PubMed

    Goh, K W; Kim, E; Lavanya, J; Kim, Y; Soh, C B

    2006-01-01

    Advances in sensor technology, personal mobile devices, and wireless broadband communications are enabling the development of an integrated personal mobile health monitoring system that can provide patients with a useful tool to assess their own health and manage their personal health information anytime and anywhere. Personal mobile devices, such as PDAs and mobile phones, are becoming more powerful integrated information management tools and play a major role in many people's lives. We focus on designing a health-monitoring system for people who suffer from cardiac arrhythmias. We have developed computer simulation models to evaluate the performance of appropriate electrocardiogram (ECG) analysis techniques that can be implemented on personal mobile devices. This paper describes an ECG analyzer to perform ECG beat and episode detection and classification. We have obtained promising preliminary results from our study. Also, we discuss several key considerations when implementing a mobile health monitoring solution. The mobile ECG analyzer would become a front-end patient health data acquisition module, which is connected to the Personal Health Information Management System (PHIMS) for data repository.

  7. A wearable 12-lead ECG acquisition system with fabric electrodes.

    PubMed

    Haoshi Zhang; Lan Tian; Huiyang Lu; Ming Zhou; Haiqing Zou; Peng Fang; Fuan Yao; Guanglin Li

    2017-07-01

    Continuous electrocardiogram (ECG) monitoring is significant for prevention of heart disease and is becoming an important part of personal and family health care. In most of the existing wearable solutions, conventional metal sensors and corresponding chips are simply integrated into clothes and usually could only collect few leads of ECG signals that could not provide enough information for diagnosis of cardiac diseases such as arrhythmia and myocardial ischemia. In this study, a wearable 12-lead ECG acquisition system with fabric electrodes was developed and could simultaneously process 12 leads of ECG signals. By integrating the fabric electrodes into a T-shirt, the wearable system would provide a comfortable and convenient user interface for ECG recording. For comparison, the proposed fabric electrode and the gelled traditional metal electrodes were used to collect ECG signals on a subject, respectively. The approximate entropy (ApEn) of ECG signals from both types of electrodes were calculated. The experimental results show that the fabric electrodes could achieve similar performance as the gelled metal electrodes. This preliminary work has demonstrated that the developed ECG system with fabric electrodes could be utilized for wearable health management and telemedicine applications.

  8. An ECG ambulatory system with mobile embedded architecture for ST-segment analysis.

    PubMed

    Miranda-Cid, Alejandro; Alvarado-Serrano, Carlos

    2010-01-01

    A prototype of a ECG ambulatory system for long term monitoring of ST segment of 3 leads, low power, portability and data storage in solid state memory cards has been developed. The solution presented is based in a mobile embedded architecture of a portable entertainment device used as a tool for storage and processing of bioelectric signals, and a mid-range RISC microcontroller, PIC 16F877, which performs the digitalization and transmission of ECG. The ECG amplifier stage is a low power, unipolar voltage and presents minimal distortion of the phase response of high pass filter in the ST segment. We developed an algorithm that manages access to files through an implementation for FAT32, and the ECG display on the device screen. The records are stored in TXT format for further processing. After the acquisition, the system implemented works as a standard USB mass storage device.

  9. Community-Based ECG Monitoring System for Patients with Cardiovascular Diseases.

    PubMed

    Lin, Bor-Shyh; Wong, Alice M; Tseng, Kevin C

    2016-04-01

    This study aims to develop a community-based electrocardiogram (ECG) monitoring system for cardiac outpatients to wirelessly detect heart rate, provide personalized healthcare, and enhance interactive social contact because of the prevalence of deaths from cardiovascular disease and the growing problem of aging in the world. The system not only strengthens the performance of the ECG monitoring system but also emphasizes the ergonomic design of wearable devices and user interfaces. In addition, it enables medical professionals to diagnose cardiac symptoms remotely and electronically manage medical reports and suggestions. The experimental result shows high performance of the dry electrode, even in dynamic conditions. The comparison result with different ECG healthcare systems shows the essential factors that the system should possess and the capability of the proposed system. Finally, a user survey was conducted based on the unified theory of acceptance and users of technology (UTAUT) model.

  10. An ECG storage and retrieval system embedded in client server HIS utilizing object-oriented DB.

    PubMed

    Wang, C; Ohe, K; Sakurai, T; Nagase, T; Kaihara, S

    1996-02-01

    In the University of Tokyo Hospital, the improved client server HIS has been applied to clinical practice and physicians can order prescription, laboratory examination, ECG examination and radiographic examination, etc. directly by themselves and read results of these examinations, except medical signal waves, schema and image, on UNIX workstations. Recently, we designed and developed an ECG storage and retrieval system embedded in the client server HIS utilizing object-oriented database to take the first step in dealing with digitized signal, schema and image data and show waves, graphics, and images directly to physicians by the client server HIS. The system was developed based on object-oriented analysis and design, and implemented with object-oriented database management system (OODMS) and C++ programming language. In this paper, we describe the ECG data model, functions of the storage and retrieval system, features of user interface and the result of its implementation in the HIS.

  11. A PC-based generator of surface ECG potentials for computer electrocardiograph testing.

    PubMed

    Franchi, D; Palagi, G; Bedini, R

    1994-02-01

    The system is composed of an electronic circuit, connected to a PC, whose outputs, starting from ECGs digitally collected by commercial interpretative electrocardiographs, simulate virtual patients' limb and chest electrode potentials. Appropriate software manages the D/A conversion and lines up the original short-term signal in a ring buffer to generate continuous ECG traces. The device also permits the addition of artifacts and/or baseline wanders/shifts on each lead separately. The system has been accurately tested and statistical indexes have been computed to quantify the reproduction accuracy analyzing, in the generated signal, both the errors induced on the fiducial point measurements and the capability to retain the diagnostic significance. The device integrated with an annotated ECG data base constitutes a reliable and powerful system to be used in the quality assurance testing of computer electrocardiographs.

  12. PDF-ECG in clinical practice: A model for long-term preservation of digital 12-lead ECG data.

    PubMed

    Sassi, Roberto; Bond, Raymond R; Cairns, Andrew; Finlay, Dewar D; Guldenring, Daniel; Libretti, Guido; Isola, Lamberto; Vaglio, Martino; Poeta, Roberto; Campana, Marco; Cuccia, Claudio; Badilini, Fabio

    In clinical practice, data archiving of resting 12-lead electrocardiograms (ECGs) is mainly achieved by storing a PDF report in the hospital electronic health record (EHR). When available, digital ECG source data (raw samples) are only retained within the ECG management system. The widespread availability of the ECG source data would undoubtedly permit successive analysis and facilitate longitudinal studies, with both scientific and diagnostic benefits. PDF-ECG is a hybrid archival format which allows to store in the same file both the standard graphical report of an ECG together with its source ECG data (waveforms). Using PDF-ECG as a model to address the challenge of ECG data portability, long-term archiving and documentation, a real-world proof-of-concept test was conducted in a northern Italy hospital. A set of volunteers undertook a basic ECG using routine hospital equipment and the source data captured. Using dedicated web services, PDF-ECG documents were then generated and seamlessly uploaded in the hospital EHR, replacing the standard PDF reports automatically generated at the time of acquisition. Finally, the PDF-ECG files could be successfully retrieved and re-analyzed. Adding PDF-ECG to an existing EHR had a minimal impact on the hospital's workflow, while preserving the ECG digital data. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Multi-purpose ECG telemetry system.

    PubMed

    Marouf, Mohamed; Vukomanovic, Goran; Saranovac, Lazar; Bozic, Miroslav

    2017-06-19

    The Electrocardiogram ECG is one of the most important non-invasive tools for cardiac diseases diagnosis. Taking advantage of the developed telecommunication infrastructure, several approaches that address the development of telemetry cardiac devices were introduced recently. Telemetry ECG devices allow easy and fast ECG monitoring of patients with suspected cardiac issues. Choosing the right device with the desired working mode, signal quality, and the device cost are still the main obstacles to massive usage of these devices. In this paper, we introduce design, implementation, and validation of a multi-purpose telemetry system for recording, transmission, and interpretation of ECG signals in different recording modes. The system consists of an ECG device, a cloud-based analysis pipeline, and accompanied mobile applications for physicians and patients. The proposed ECG device's mechanical design allows laypersons to easily record post-event short-term ECG signals, using dry electrodes without any preparation. Moreover, patients can use the device to record long-term signals in loop and holter modes, using wet electrodes. In order to overcome the problem of signal quality fluctuation due to using different electrodes types and different placements on subject's chest, customized ECG signal processing and interpretation pipeline is presented for each working mode. We present the evaluation of the novel short-term recorder design. Recording of an ECG signal was performed for 391 patients using a standard 12-leads golden standard ECG and the proposed patient-activated short-term post-event recorder. In the validation phase, a sample of validation signals followed peer review process wherein two experts annotated the signals in terms of signal acceptability for diagnosis.We found that 96% of signals allow detecting arrhythmia and other signal's abnormal changes. Additionally, we compared and presented the correlation coefficient and the automatic QRS delineation results of both short-term post-event recorder and 12-leads golden standard ECG recorder. The proposed multi-purpose ECG device allows physicians to choose the working mode of the same device according to the patient status. The proposed device was designed to allow patients to manage the technical requirements of both working modes. Post-event short-term ECG recording using the proposed design provide physicians reliable three ECG leads with direct symptom-rhythm correlation.

  14. The impact of remote patient monitoring in managing silent myocardial infarction in a residential home setting.

    PubMed

    Clarke, Malcolm; Bratan, Tanja; Kulkarni, Sadhana; Jones, Russell

    2007-07-01

    We describe the impact of a remote patient monitoring (RPM) system implemented in residential care homes. The service was designed to support the staff in managing patients that presented with non-specific symptoms. The system allows vital signs to be transmitted to a central server. The medical professional may then observe the data and provide advice to the staff on optimum management. Our system has been evaluated for 18 months and largely provided routine measurements. During this period, three residents presented with non specific symptoms that were investigated using the RPM system. One patient had symptoms over a weekend, and the problem remained unresolved on Monday. The resident continued to only complain of feeling unwell, but reported no specific symptoms. Vital signs data were then sent and the doctor consulted. The electrocardiogram (ECG) showed significant ST segment changes. Repetitive measurements of the ECG, heart rate, and oxygen saturation of the blood (SpO2) were made every 5 minutes. The resident had a history angina and CHF. The staff was asked to give the patient aspirin and anti-angina drug. The ECG was seen to resolve after 40 minutes, but the SpO2 was falling. The decision to send to hospital was taken at this point. Two further patients with significant ECG changes were observed during the period of the project, and again both were asymptomatic, but in these cases the condition resolved and hospital admission was avoided. Feedback from users has been very positive. Staff found that the system gave them support to make better informed decisions on patient management, especially when determining whether to admit the person to hospital when reaching end of life. Further comments were that the system also proved useful to reassure relatives during these final stages. Our project demonstrated that significant cardiac events occur in the elderly population of residential homes without symptoms; and that RPM can be used by non medical staff to manage asymptomatic patients in the community.

  15. The role of technology and telemetry medicine in the initial management of a ST-segment elevated myocardial infarction in a rural emergency department.

    PubMed

    Hood, Michael L

    2018-05-01

    The 12-lead electrocardiogram (ECG) is an integral part of the diagnostic tools available for recognising a patient who is experiencing an ST-segment elevated myocardial infarction (STEMI). Consequently, a great emphasis is placed on the rapid acquisition and expert interpretation of the 12-lead ECG so that the appropriate reperfusion management might be commenced to optimise patient outcomes by preventing further damage to the myocardium. With the advancement of telemetric and diagnostic abilities of the modern ECG machine, the role of frontline rural emergency clinicians is as important as ever. This clinical case report describes the presentation and management of a person experiencing a STEMI in a rural Australian hospital emergency department setting. The emanating point of interest from this case report is the early clinician recognition of significant ST-segment elevation in multiple leads of the initial ECG trace, indicating a STEMI. Despite the presence of significant acute ST-segment changes throughout the trace, the ECG's diagnostic analysis of the 12-lead ECG did not identify it as meeting STEMI criteria. Subsequently, the ECG was not recommended by the ECG machine for telemetric transmission to the remote on-call cardiologist for immediate STEMI management guidance. This article focuses on the telemetric technology utilised in the management of STEMIs in the rural emergency department, the diagnostic ability of the modern ECG and the role of the frontline rural emergency clinician in the utilisation of such technology. Competent utilisation of key technologies applied to the ECG machine require the clinician to be well trained in the technical use of the equipment, have a thorough understanding of how the technology interacts within the established clinical pathway and be ready to apply its use in a timely manner in order to prevent delays in treatment. Furthermore, an over-reliance on the diagnostic ability of the modern ECG machine in the rural or remote context may potentially lead to poor patient outcomes.

  16. A protocol for a prospective observational study using chest and thumb ECG: transient ECG assessment in stroke evaluation (TEASE) in Sweden.

    PubMed

    Magnusson, Peter; Koyi, Hirsh; Mattsson, Gustav

    2018-04-03

    Atrial fibrillation (AF) causes ischaemic stroke and based on risk factor evaluation warrants anticoagulation therapy. In stroke survivors, AF is typically detected with short-term ECG monitoring in the stroke unit. Prolonged continuous ECG monitoring requires substantial resources while insertable cardiac monitors are invasive and costly. Chest and thumb ECG could provide an alternative for AF detection poststroke.The primary objective of our study is to assess the incidence of newly diagnosed AF during 28 days of chest and thumb ECG monitoring in cryptogenic stroke. Secondary objectives are to assess health-related quality of life (HRQoL) using short-form health survey (SF-36) and the feasibility of the Coala Heart Monitor in patients who had a stroke. Stroke survivors in Region Gävleborg, Sweden, will be eligible for the study from October 2017. Patients with a history of ischaemic stroke without documented AF before or during ECG evaluation in the stroke unit will be evaluated by the chest and thumb ECG system Coala Heart Monitor. The monitoring system is connected to a smartphone application which allows for remote monitoring and prompt advice on clinical management. Over a period of 28 days, patients will be monitored two times a day and may activate the ECG recording at symptoms. On completion, the system is returned by mail. This system offers a possibility to evaluate the presence of AF poststroke, but the feasibility of this system in patients who recently suffered from a stroke is unknown. In addition, HRQoL using SF-36 in comparison to Swedish population norms will be assessed. The feasibility of the Coala Heart Monitor will be assessed by a self-developed questionnaire. The study was approved by The Regional Ethical Committee in Uppsala (2017/321). The database will be closed after the last follow-up, followed by statistical analyses, interpretation of results and dissemination to a scientific journal. NCT03301662; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. An Autonomous Wireless Sensor Node With Asynchronous ECG Monitoring in 0.18 μ m CMOS.

    PubMed

    Mansano, Andre L; Li, Yongjia; Bagga, Sumit; Serdijn, Wouter A

    2016-06-01

    The design of a 13.56 MHz/402 MHz autonomous wireless sensor node with asynchronous ECG monitoring for near field communication is presented. The sensor node consists of an RF energy harvester (RFEH), a power management unit, an ECG readout, a data encoder and an RF backscattering transmitter. The energy harvester supplies the system with 1.25 V and offers a power conversion efficiency of 19% from a -13 dBm RF source at 13.56 MHz. The power management unit regulates the output voltage of the RFEH to supply the ECG readout with VECG = 0.95 V and the data encoder with VDE = 0.65 V . The ECG readout comprises an analog front-end (low noise amplifier and programmable voltage to current converter) and an asynchronous level crossing ADC with 8 bits resolution. The ADC output is encoded by a pulse generator that drives a backscattering transmitter at 402 MHz. The total power consumption of the sensor node circuitry is 9.7 μ W for a data rate of 90 kb/s and a heart rate of 70 bpm. The chip has been designed in a 0.18 μm CMOS process and shows superior RF input power sensitivity and lower power consumption when compared to previous works.

  18. Electrocardiogram interpretation and arrhythmia management: a primary and secondary care survey.

    PubMed

    Begg, Gordon; Willan, Kathryn; Tyndall, Keith; Pepper, Chris; Tayebjee, Muzahir

    2016-05-01

    There is increasing desire among service commissioners to treat arrhythmia in primary care. Accurate interpretation of the electrocardiogram (ECG) is fundamental to this. ECG interpretation has previously been shown to vary widely but there is little recent data. To examine the interpretation of ECGs in primary and secondary care. A cross-sectional survey of participants' interpretation of six ECGs and hypothetical management of patients based on those ECGs, at primary care educational events, and a cardiology department in Leeds. A total of 262 primary care clinicians and 20 cardiology clinicians were surveyed via questionnaire. Answers were compared with expert electrophysiologist opinion. In primary care, abnormal ECGs were interpreted as normal by 23% of responders. ST elevation and prolonged QT were incorrectly interpreted as normal by 1% and 22%, respectively. In cardiology, abnormal ECGs were interpreted as normal by 3%. ECG provision and interpretation remains inconsistent in both primary and secondary care. Primary care practitioners are less experienced and less confident with ECG interpretation than cardiologists, and require support in this area. © British Journal of General Practice 2016.

  19. Development of a Wearable Cardiac Monitoring System for Behavioral Neurocardiac Training: A Usability Study

    PubMed Central

    Morita, Plinio P; Tallevi, Kevin; Armour, Kevin; Li, John; Nolan, Robert P; Cafazzo, Joseph A

    2016-01-01

    Background Elevated blood pressure is one of the main risk factors for death globally. Behavioral neurocardiac training (BNT) is a complementary approach to blood pressure and stress management that is intended to exercise the autonomic reflexes, improve stress recovery, and lower blood pressure. BNT involves cognitive-behavioral therapy with a paced breathing technique and heart rate variability biofeedback. BNT is limited to in-clinic delivery and faces an accessibility barrier because of the need for clinical oversight and the use of complex monitoring tools. Objective The objective of this project was to design, develop, and evaluate a wearable electrocardiographic (ECG) sensor system for the delivery of BNT in a home setting. Methods The wearable sensor system, Beat, consists of an ECG sensor and a mobile app. It was developed iteratively using the principles of test-driven Agile development and user-centered design. A usability study was conducted at Toronto General Hospital to evaluate feasibility and user experience and identify areas of improvement. Results The Beatsensor was designed as a modular patch to be worn on the user’s chest and uses standard ECG electrodes. It streams a single-lead ECG wirelessly to a mobile phone using Bluetooth Low Energy. The use of small, low-power electronics, a low device profile, and a tapered enclosure allowed for a device that can be unobtrusively worn under clothing. The sensor was designed to operate with a mobile app that guides users through the BNT exercises to train them to a slow-paced breathing technique for stress recovery. The BNT app uses the ECG captured by the sensor to provide heart rate variability biofeedback in the form of a real-time heart rate waveform to complement and reinforce the impact of the training. Usability testing (n=6) indicated that the overall response to the design and user experience of the system was perceived positively. All participants indicated that the system had a positive effect on stress management and that they would use it at home. Areas of improvement were identified, which focused primarily on the delivery of training and education on BNT through the app. Conclusions The outcome of this project was a wearable sensor system to deliver BNT at home. The system has the potential to offer a complementary approach to blood pressure and stress management at home and reduce current accessibility barriers. PMID:27106171

  20. Development of a Wearable Cardiac Monitoring System for Behavioral Neurocardiac Training: A Usability Study.

    PubMed

    Uddin, Akib A; Morita, Plinio P; Tallevi, Kevin; Armour, Kevin; Li, John; Nolan, Robert P; Cafazzo, Joseph A

    2016-04-22

    Elevated blood pressure is one of the main risk factors for death globally. Behavioral neurocardiac training (BNT) is a complementary approach to blood pressure and stress management that is intended to exercise the autonomic reflexes, improve stress recovery, and lower blood pressure. BNT involves cognitive-behavioral therapy with a paced breathing technique and heart rate variability biofeedback. BNT is limited to in-clinic delivery and faces an accessibility barrier because of the need for clinical oversight and the use of complex monitoring tools. The objective of this project was to design, develop, and evaluate a wearable electrocardiographic (ECG) sensor system for the delivery of BNT in a home setting. The wearable sensor system, Beat, consists of an ECG sensor and a mobile app. It was developed iteratively using the principles of test-driven Agile development and user-centered design. A usability study was conducted at Toronto General Hospital to evaluate feasibility and user experience and identify areas of improvement. The Beat sensor was designed as a modular patch to be worn on the user's chest and uses standard ECG electrodes. It streams a single-lead ECG wirelessly to a mobile phone using Bluetooth Low Energy. The use of small, low-power electronics, a low device profile, and a tapered enclosure allowed for a device that can be unobtrusively worn under clothing. The sensor was designed to operate with a mobile app that guides users through the BNT exercises to train them to a slow-paced breathing technique for stress recovery. The BNT app uses the ECG captured by the sensor to provide heart rate variability biofeedback in the form of a real-time heart rate waveform to complement and reinforce the impact of the training. Usability testing (n=6) indicated that the overall response to the design and user experience of the system was perceived positively. All participants indicated that the system had a positive effect on stress management and that they would use it at home. Areas of improvement were identified, which focused primarily on the delivery of training and education on BNT through the app. The outcome of this project was a wearable sensor system to deliver BNT at home. The system has the potential to offer a complementary approach to blood pressure and stress management at home and reduce current accessibility barriers.

  1. The future of remote ECG monitoring systems.

    PubMed

    Guo, Shu-Li; Han, Li-Na; Liu, Hong-Wei; Si, Quan-Jin; Kong, De-Feng; Guo, Fu-Su

    2016-09-01

    Remote ECG monitoring systems are becoming commonplace medical devices for remote heart monitoring. In recent years, remote ECG monitoring systems have been applied in the monitoring of various kinds of heart diseases, and the quality of the transmission and reception of the ECG signals during remote process kept advancing. However, there remains accompanying challenges. This report focuses on the three components of the remote ECG monitoring system: patient (the end user), the doctor workstation, and the remote server, reviewing and evaluating the imminent challenges on the wearable systems, packet loss in remote transmission, portable ECG monitoring system, patient ECG data collection system, and ECG signals transmission including real-time processing ST segment, R wave, RR interval and QRS wave, etc. This paper tries to clarify the future developmental strategies of the ECG remote monitoring, which can be helpful in guiding the research and development of remote ECG monitoring.

  2. Comparison of diagnostic value using a small, single channel, P-wave centric sternal ECG monitoring patch with a standard 3-lead Holter system over 24 hours.

    PubMed

    Smith, Warren M; Riddell, Fiona; Madon, Morag; Gleva, Marye J

    2017-03-01

    To compare simultaneous recordings from an external patch system specifically designed to ensure better P-wave recordings and standard Holter monitor to determine diagnostic efficacy. Holter monitors are a mainstay of clinical practice, but are cumbersome to access and wear and P-wave signal quality is frequently inadequate. This study compared the diagnostic efficacy of the P-wave centric electrocardiogram (ECG) patch (Carnation Ambulatory Monitor) to standard 3-channel (leads V1, II, and V5) Holter monitor (Northeast Monitoring, Maynard, MA). Patients were referred to a hospital Holter clinic for standard clinical indications. Each patient wore both devices simultaneously and served as their own control. Holter and Patch reports were read in a blinded fashion by experienced electrophysiologists unaware of the findings in the other corresponding ECG recording. All patients, technicians, and physicians completed a questionnaire on comfort and ease of use, and potential complications. In all 50 patients, the P-wave centric patch recording system identified rhythms in 23 patients (46%) that altered management, compared to 6 Holter patients (12%), P<.001. The patch ECG intervals PR, QRS and QT correlated well with the Holter ECG intervals having correlation coefficients of 0.93, 0.86, and 0.94, respectively. Finally, 48 patients (96%) preferred wearing the patch monitor. A single-channel ambulatory patch ECG monitor, designed specifically to ensure that the P-wave component of the ECG be visible, resulted in a significantly improved rhythm diagnosis and avoided inaccurate diagnoses made by the standard 3-channel Holter monitor. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Utility of the Electrocardiogram in Drug Overdose and Poisoning: Theoretical Considerations and Clinical Implications

    PubMed Central

    Yates, Christopher; Manini, Alex F

    2012-01-01

    The ECG is a rapidly available clinical tool that can help clinicians manage poisoned patients. Specific myocardial effects of cardiotoxic drugs have well-described electrocardiographic manifestations. In the practice of clinical toxicology, classic ECG changes may hint at blockade of ion channels, alterations of adrenergic tone, or dysfunctional metabolic activity of the myocardium. This review will offer a structured approach to ECG interpretation in poisoned patients with a focus on clinical implications and ECG-based management recommendations in the initial evaluation of patients with acute cardiotoxicity. PMID:22708912

  4. A fabric wrist patch sensor for continuous and comprehensive monitoring of the cardiovascular system.

    PubMed

    Kwonjoon Lee; Kiseok Song; Taehwan Roh; Hoi-Jun Yoo

    2016-08-01

    The wrist patch-type ECG/APW sensor system is proposed for continuous and comprehensive monitoring of the patient's cardiovascular system. The wrist patch-type ECG/APW sensor system is consists of ECG/APW sensor, ECG/APW electrodes, and base station for real-time monitoring of the patient's status. The ECG/APW sensor and electrodes are composed of wrist patch, bandage-type ECG electrode and fabric APW electrode, respectively so that the patient's cardiovascular system can be continuously monitored in daily life with free hand-movement. Since the proposed wrist patchtype ECG/APW sensor simultaneously measures ECG/APW, the cardiac indicators, such as HR and PAT, can be extracted for comprehensive and accurate monitoring of the patient's cardiovascular system. The proposed wrist patch-type ECG/APW sensor system is successfully verified using the commercial PPG sensor (RP520) and demonstrated with the customized Android application on the smart phone.

  5. Arrhythmia Classification Based on Multi-Domain Feature Extraction for an ECG Recognition System.

    PubMed

    Li, Hongqiang; Yuan, Danyang; Wang, Youxi; Cui, Dianyin; Cao, Lu

    2016-10-20

    Automatic recognition of arrhythmias is particularly important in the diagnosis of heart diseases. This study presents an electrocardiogram (ECG) recognition system based on multi-domain feature extraction to classify ECG beats. An improved wavelet threshold method for ECG signal pre-processing is applied to remove noise interference. A novel multi-domain feature extraction method is proposed; this method employs kernel-independent component analysis in nonlinear feature extraction and uses discrete wavelet transform to extract frequency domain features. The proposed system utilises a support vector machine classifier optimized with a genetic algorithm to recognize different types of heartbeats. An ECG acquisition experimental platform, in which ECG beats are collected as ECG data for classification, is constructed to demonstrate the effectiveness of the system in ECG beat classification. The presented system, when applied to the MIT-BIH arrhythmia database, achieves a high classification accuracy of 98.8%. Experimental results based on the ECG acquisition experimental platform show that the system obtains a satisfactory classification accuracy of 97.3% and is able to classify ECG beats efficiently for the automatic identification of cardiac arrhythmias.

  6. Arrhythmia Classification Based on Multi-Domain Feature Extraction for an ECG Recognition System

    PubMed Central

    Li, Hongqiang; Yuan, Danyang; Wang, Youxi; Cui, Dianyin; Cao, Lu

    2016-01-01

    Automatic recognition of arrhythmias is particularly important in the diagnosis of heart diseases. This study presents an electrocardiogram (ECG) recognition system based on multi-domain feature extraction to classify ECG beats. An improved wavelet threshold method for ECG signal pre-processing is applied to remove noise interference. A novel multi-domain feature extraction method is proposed; this method employs kernel-independent component analysis in nonlinear feature extraction and uses discrete wavelet transform to extract frequency domain features. The proposed system utilises a support vector machine classifier optimized with a genetic algorithm to recognize different types of heartbeats. An ECG acquisition experimental platform, in which ECG beats are collected as ECG data for classification, is constructed to demonstrate the effectiveness of the system in ECG beat classification. The presented system, when applied to the MIT-BIH arrhythmia database, achieves a high classification accuracy of 98.8%. Experimental results based on the ECG acquisition experimental platform show that the system obtains a satisfactory classification accuracy of 97.3% and is able to classify ECG beats efficiently for the automatic identification of cardiac arrhythmias. PMID:27775596

  7. A Remote Health Monitoring System for the Elderly Based on Smart Home Gateway

    PubMed Central

    Shao, Minggang

    2017-01-01

    This paper proposed a remote health monitoring system for the elderly based on smart home gateway. The proposed system consists of three parts: the smart clothing, the smart home gateway, and the health care server. The smart clothing collects the elderly's electrocardiogram (ECG) and motion signals. The home gateway is used for data transmission. The health care server provides services of data storage and user information management; it is constructed on the Windows-Apache-MySQL-PHP (WAMP) platform and is tested on the Ali Cloud platform. To resolve the issues of data overload and network congestion of the home gateway, an ECG compression algorithm is applied. System demonstration shows that the ECG signals and motion signals of the elderly can be monitored. Evaluation of the compression algorithm shows that it has a high compression ratio and low distortion and consumes little time, which is suitable for home gateways. The proposed system has good scalability, and it is simple to operate. It has the potential to provide long-term and continuous home health monitoring services for the elderly. PMID:29204258

  8. A Remote Health Monitoring System for the Elderly Based on Smart Home Gateway.

    PubMed

    Guan, Kai; Shao, Minggang; Wu, Shuicai

    2017-01-01

    This paper proposed a remote health monitoring system for the elderly based on smart home gateway. The proposed system consists of three parts: the smart clothing, the smart home gateway, and the health care server. The smart clothing collects the elderly's electrocardiogram (ECG) and motion signals. The home gateway is used for data transmission. The health care server provides services of data storage and user information management; it is constructed on the Windows-Apache-MySQL-PHP (WAMP) platform and is tested on the Ali Cloud platform. To resolve the issues of data overload and network congestion of the home gateway, an ECG compression algorithm is applied. System demonstration shows that the ECG signals and motion signals of the elderly can be monitored. Evaluation of the compression algorithm shows that it has a high compression ratio and low distortion and consumes little time, which is suitable for home gateways. The proposed system has good scalability, and it is simple to operate. It has the potential to provide long-term and continuous home health monitoring services for the elderly.

  9. Evaluation of an electrocardiogram on QR code.

    PubMed

    Nakayama, Masaharu; Shimokawa, Hiroaki

    2013-01-01

    An electrocardiogram (ECG) is an indispensable tool to diagnose cardiac diseases, such as ischemic heart disease, myocarditis, arrhythmia, and cardiomyopathy. Since ECG patterns vary depend on patient status, it is also used to monitor patients during treatment and comparison with ECGs with previous results is important for accurate diagnosis. However, the comparison requires connection to ECG data server in a hospital and the availability of data connection among hospitals is limited. To improve the portability and availability of ECG data regardless of server connection, we here introduce conversion of ECG data into 2D barcodes as text data and decode of the QR code for drawing ECG with Google Chart API. Fourteen cardiologists and six general physicians evaluated the system using iPhone and iPad. Overall, they were satisfied with the system in usability and accuracy of decoded ECG compared to the original ECG. This new coding system may be useful in utilizing ECG data irrespective of server connections.

  10. Advanced ECG in 2016: is there more than just a tracing?

    PubMed

    Reichlin, Tobias; Abächerli, Roger; Twerenbold, Raphael; Kühne, Michael; Schaer, Beat; Müller, Christian; Sticherling, Christian; Osswald, Stefan

    2016-01-01

    The 12-lead electrocardiogram (ECG) is the most frequently used technology in clinical cardiology. It is critical for evidence-based management of patients with most cardiovascular conditions, including patients with acute myocardial infarction, suspected chronic cardiac ischaemia, cardiac arrhythmias, heart failure and implantable cardiac devices. In contrast to many other techniques in cardiology, the ECG is simple, small, mobile, universally available and cheap, and therefore particularly attractive. Standard ECG interpretation mainly relies on direct visual assessment. The progress in biomedical computing and signal processing, and the available computational power offer fascinating new options for ECG analysis relevant to all fields of cardiology. Several digital ECG markers and advanced ECG technologies have shown promise in preliminary studies. This article reviews promising novel surface ECG technologies in three different fields. (1) For the detection of myocardial ischaemia and infarction, QRS morphology feature analysis, the analysis of high frequency QRS components (HF-QRS) and methods using vectorcardiography as well as ECG imaging are discussed. (2) For the identification and management of patients with cardiac arrhythmias, methods of advanced P-wave analysis are discussed and the concept of ECG imaging for noninvasive localisation of cardiac arrhythmias is presented. (3) For risk stratification of sudden cardiac death and the selection of patients for medical device therapy, several novel markers including an automated QRS-score for scar quantification, the QRS-T angle or the T-wave peak-to-end-interval are discussed. Despite the existing preliminary data, none of the advanced ECG markers and technologies has yet accomplished the transition into clinical practice. Further refinement of these technologies and broader validation in large unselected patient cohorts are the critical next step needed to facilitate translation of advanced ECG technologies into clinical cardiology.

  11. [Implementation of ECG Monitoring System Based on Internet of Things].

    PubMed

    Lu, Liangliang; Chen, Minya

    2015-11-01

    In order to expand the capabilities of hospital's traditional ECG device and enhance medical staff's work efficiency, an ECG monitoring system based on internet of things is introduced. The system can monitor ECG signals in real time and analyze data using ECG sensor, PDA, Web servers, which embeds C language, Android systems, .NET, wireless network and other technologies. After experiments, it can be showed that the system has high reliability and stability and can bring the convenience to medical staffs.

  12. A remote access ecg monitoring system - biomed 2009.

    PubMed

    Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Iwamoto, Junichi; Hahn, Allen W; Caldwell, W Morton

    2009-01-01

    We have developed a remotely accessible telemedicine system for monitoring a patient's electrocardiogram (ECG). The system consists of an ECG recorder mounted on chest electrodes and a physician's laptop personal computer. This ECG recorder is designed with a variable gain instrumentation amplifier; a low power 8-bit single-chip microcomputer; two 128KB EEPROMs and 2.4 GHz low transmit power mobile telephone. When the physician wants to monitor the patient's ECG, he/she calls directly from the laptop PC to the ECG recorder's phone and the recorder sends the ECG to the computer. The electrode-mounted recorder continuously samples the ECG. Additionally, when the patient feels a heart discomfort, he/she pushes a data transmission switch on the recorder and the recorder sends the recorded ECG waveforms of the two prior minutes, and for two minutes after the switch is pressed. The physician can display and monitor the data on the computer's liquid crystal display.

  13. [Experience in the use of equipment for ECG system analysis in municipal polyclinics].

    PubMed

    Bondarenko, A A

    2006-01-01

    Two electrocardiographs, an analog-digital electrocardiograph with preliminary analog filtering of signal and a smart cardiograph implemented as a PC-compatible device without preliminary analog filtering, are considered. Advantages and disadvantages of ECG systems based on artificial intelligence are discussed. ECG interpretation modes provided by the two electrocardiographs are considered. The reliability of automatic ECG interpretation is assessed. Problems of rational use of automated ECG processing systems are discussed.

  14. Highly wearable cuff-less blood pressure and heart rate monitoring with single-arm electrocardiogram and photoplethysmogram signals.

    PubMed

    Zhang, Qingxue; Zhou, Dian; Zeng, Xuan

    2017-02-06

    Long-term continuous systolic blood pressure (SBP) and heart rate (HR) monitors are of tremendous value to medical (cardiovascular, circulatory and cerebrovascular management), wellness (emotional and stress tracking) and fitness (performance monitoring) applications, but face several major impediments, such as poor wearability, lack of widely accepted robust SBP models and insufficient proofing of the generalization ability of calibrated models. This paper proposes a wearable cuff-less electrocardiography (ECG) and photoplethysmogram (PPG)-based SBP and HR monitoring system and many efforts are made focusing on above challenges. Firstly, both ECG/PPG sensors are integrated into a single-arm band to provide a super wearability. A highly convenient but challenging single-lead configuration is proposed for weak single-arm-ECG acquisition, instead of placing the electrodes on the chest, or two wrists. Secondly, to identify heartbeats and estimate HR from the motion artifacts-sensitive weak arm-ECG, a machine learning-enabled framework is applied. Then ECG-PPG heartbeat pairs are determined for pulse transit time (PTT) measurement. Thirdly, a PTT&HR-SBP model is applied for SBP estimation, which is also compared with many PTT-SBP models to demonstrate the necessity to introduce HR information in model establishment. Fourthly, the fitted SBP models are further evaluated on the unseen data to illustrate the generalization ability. A customized hardware prototype was established and a dataset collected from ten volunteers was acquired to evaluate the proof-of-concept system. The semi-customized prototype successfully acquired from the left upper arm the PPG signal, and the weak ECG signal, the amplitude of which is only around 10% of that of the chest-ECG. The HR estimation has a mean absolute error (MAE) and a root mean square error (RMSE) of only 0.21 and 1.20 beats per min, respectively. Through the comparative analysis, the PTT&HR-SBP models significantly outperform the PTT-SBP models. The testing performance is 1.63 ± 4.44, 3.68, 4.71 mmHg in terms of mean error ± standard deviation, MAE and RMSE, respectively, indicating a good generalization ability on the unseen fresh data. The proposed proof-of-concept system is highly wearable, and its robustness is thoroughly evaluated on different modeling strategies and also the unseen data, which are expected to contribute to long-term pervasive hypertension, heart health and fitness management.

  15. Pit-a-Pat: A Smart Electrocardiogram System for Detecting Arrhythmia.

    PubMed

    Park, Juyoung; Lee, Kuyeon; Kang, Kyungtae

    2015-10-01

    Electrocardiogram (ECG) telemonitoring is one of the most promising applications of medical telemetry. However, previous approaches to ECG telemonitoring have largely relied on public databases of ECG results. In this article we propose a smart ECG system called Pit-a-Pat, which extracts features from ECG signals and detects arrhythmia. It is designed to run on an Android™ (Google, Mountain View, CA) device, without requiring modifications to other software. We implemented the Pit-a-Pat system using a commercial ECG device, and the experimental results demonstrate the effectiveness and accuracy of Pit-a-Pat for monitoring the ECG signal and analyzing the cardiac activity of a mobile patient. The proposed system allows monitoring of cardiac activity with automatic analysis, thereby providing a convenient, inexpensive, and ubiquitous adjunct to personal healthcare.

  16. Cloud-ECG for real time ECG monitoring and analysis.

    PubMed

    Xia, Henian; Asif, Irfan; Zhao, Xiaopeng

    2013-06-01

    Recent advances in mobile technology and cloud computing have inspired numerous designs of cloud-based health care services and devices. Within the cloud system, medical data can be collected and transmitted automatically to medical professionals from anywhere and feedback can be returned to patients through the network. In this article, we developed a cloud-based system for clients with mobile devices or web browsers. Specially, we aim to address the issues regarding the usefulness of the ECG data collected from patients themselves. Algorithms for ECG enhancement, ECG quality evaluation and ECG parameters extraction were implemented in the system. The system was demonstrated by a use case, in which ECG data was uploaded to the web server from a mobile phone at a certain frequency and analysis was performed in real time using the server. The system has been proven to be functional, accurate and efficient. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. Construction of a Resting High Fidelity ECG "SuperScore" for Management and Screening of Heart Disease

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; Delgado, Reynolds; Poulin, Greg; Starc, Vito; Arenare, Brian; Rahman, M. A.

    2006-01-01

    Resting conventional ECG is notoriously insensitive for detecting coronary artery disease (CAD) and only nominally useful in screening for cardiomyopathy (CM). Similarly, conventional exercise stress test ECG is both time- and labor-consuming and its accuracy in identifying CAD is suboptimal for use in population screening. We retrospectively investigated the accuracy of several advanced resting electrocardiographic (ECG) parameters, both alone and in combination, for detecting CAD and cardiomyopathy (CM).

  18. Development of a portable Linux-based ECG measurement and monitoring system.

    PubMed

    Tan, Tan-Hsu; Chang, Ching-Su; Huang, Yung-Fa; Chen, Yung-Fu; Lee, Cheng

    2011-08-01

    This work presents a portable Linux-based electrocardiogram (ECG) signals measurement and monitoring system. The proposed system consists of an ECG front end and an embedded Linux platform (ELP). The ECG front end digitizes 12-lead ECG signals acquired from electrodes and then delivers them to the ELP via a universal serial bus (USB) interface for storage, signal processing, and graphic display. The proposed system can be installed anywhere (e.g., offices, homes, healthcare centers and ambulances) to allow people to self-monitor their health conditions at any time. The proposed system also enables remote diagnosis via Internet. Additionally, the system has a 7-in. interactive TFT-LCD touch screen that enables users to execute various functions, such as scaling a single-lead or multiple-lead ECG waveforms. The effectiveness of the proposed system was verified by using a commercial 12-lead ECG signal simulator and in vivo experiments. In addition to its portability, the proposed system is license-free as Linux, an open-source code, is utilized during software development. The cost-effectiveness of the system significantly enhances its practical application for personal healthcare.

  19. Physicochemical study of mixed systems composed by bovine caseinate and the galactomannan from Gleditsia amorphoides.

    PubMed

    López, Débora N; Galante, Micaela; Alvarez, Estela M; Risso, Patricia H; Boeris, Valeria

    2017-10-01

    Model systems formed by sodium caseinate (NaCAS) and espina corona gum (ECG) were studied. There was no evidence of attractive interactions between NaCAS and ECG macromolecules. Aqueous mixtures of NaCAS and ECG phase-separate segregatively over a wide range of concentrations. According to the images obtained by confocal laser scanning microscopy, NaCAS particles form larger protein aggregates when ECG is present in the system. An increase in the hydrodynamic diameter of NaCAS particles, as a result of ECG addition, was also observed by light scattering in diluted systems. A depletion-flocculation phenomenon, in which ECG is excluded from NaCAS surface, is proposed to occur in the concentrated mixed systems, resulting in NaCAS aggregation. ECG raises the viscosity of NaCAS dispersions without affecting the Newtonian flow behaviour of NaCAS. These results contribute to improve the knowledge of a barely-studied hydrocolloid which may be useful in the development of innovative food systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Noncontact ECG system for unobtrusive long-term monitoring.

    PubMed

    McDonald, Neil J; Anumula, Harini A; Duff, Eric; Soussou, Walid

    2012-01-01

    This paper describes measurements made using an ECG system with QUASAR's capacitive bioelectrodes integrated into a pad system that is placed over a chair. QUASAR's capacitive bioelectrode has the property of measuring bioelectric potentials at a small separation from the body. This enables the measurement of ECG signals through fabric, without the removal of clothing or preparation of skin. The ECG was measured through the subject's clothing while the subject sat in the chair without any supporting action from the subject. The ECG pad system is an example of a high compliance system that places minimal requirements upon the subject and, consequently, can be used to generate a long-term record from ECG segments collected on a daily basis, providing valuable information on long-term trends in cardiac health.

  1. 3-lead acquisition using single channel ECG device developed on AD8232 analog front end for wireless ECG application

    NASA Astrophysics Data System (ADS)

    Agung, Mochammad Anugrah; Basari

    2017-02-01

    Electrocardiogram (ECG) devices measure electrical activity of the heart muscle to determine heart conditions. ECG signal quality is the key factor in determining the diseases of the heart. This paper presents the design of 3-lead acquistion on single channel wireless ECG device developed on AD8232 chip platform using microcontroller. To make the system different from others, monopole antenna 2.4 GHz is used in order to send and receive ECG signal. The results show that the system still can receive ECG signal up to 15 meters by line of sight (LOS) condition. The shape of ECG signals is precisely similar with the expected signal, although some delays occur between two consecutive pulses. For further step, the system will be applied with on-body antenna in order to investigate body to body communication that will give variation in connectivity from the others.

  2. Software design of a remote real-time ECG monitoring system

    NASA Astrophysics Data System (ADS)

    Yu, Chengbo; Tao, Hongyan

    2005-12-01

    Heart disease is one of the main diseases that threaten the health and lives of human beings. At present, the normal remote ECG monitoring system has the disadvantages of a short testing distance and limitation of monitoring lines. Because of accident and paroxysmal disease, ECG monitoring has extended from the hospital to the family. Therefore, remote ECG monitoring through the Internet has the actual value and significance. The principle and design method of software of the remote dynamic ECG monitor was presented and discussed. The monitoring software is programmed with Delphi software based on client-sever interactive mode. The application program of the system, which makes use of multithreading technology, is shown to perform in an excellent manner. The program includes remote link users and ECG processing, i.e. ECG data's receiving, real-time displaying, recording and replaying. The system can connect many clients simultaneously and perform real-time monitoring to patients.

  3. Electromagnetic Interference of Wireless Local Area Network on Electrocardiogram Monitoring System: A Case Report

    PubMed Central

    Chung, Seungmin; Yi, Joohee

    2013-01-01

    Electromagnetic interference (EMI) can affect various medical devices. Herein, we report the case of EMI from wireless local area network (WLAN) on an electrocardiogram (ECG) monitoring system. A patient who had a prior myocardial infarction participated in the cardiac rehabilitation program in the sports medicine center of our hospital under the wireless ECG monitoring system. After WLAN was installed, wireless ECG monitoring system failed to show a proper ECG signal. ECG signal was distorted when WLAN was turned on, but it was normalized after turning off the WLAN. PMID:23613696

  4. Design of a smart ECG garment based on conductive textile electrode and flexible printed circuit board.

    PubMed

    Cai, Zhipeng; Luo, Kan; Liu, Chengyu; Li, Jianqing

    2017-08-09

    A smart electrocardiogram (ECG) garment system was designed for continuous, non-invasive and comfortable ECG monitoring, which mainly consists of four components: Conductive textile electrode, garment, flexible printed circuit board (FPCB)-based ECG processing module and android application program. Conductive textile electrode and FPCB-based ECG processing module (6.8 g, 55 mm × 53 mm × 5 mm) are identified as two key techniques to improve the system's comfort and flexibility. Preliminary experimental results verified that the textile electrodes with circle shape, 40 mm size in diameter, and 5 mm thickness sponge are best suited for the long-term ECG monitoring application. The tests on the whole system confirmed that the designed smart garment can obtain long-term ECG recordings with high signal quality.

  5. ECG Identification System Using Neural Network with Global and Local Features

    ERIC Educational Resources Information Center

    Tseng, Kuo-Kun; Lee, Dachao; Chen, Charles

    2016-01-01

    This paper proposes a human identification system via extracted electrocardiogram (ECG) signals. Two hierarchical classification structures based on global shape feature and local statistical feature is used to extract ECG signals. Global shape feature represents the outline information of ECG signals and local statistical feature extracts the…

  6. Physiological Investigation of Localized Temperature Effects on Vigilance Performance

    DTIC Science & Technology

    2014-03-27

    Department of Systems Engineering Graduate School of Engineering and Management Air Force Institute of Technology Air University Air Education and...Training Command In Partial Fulfillment of the Requirements for the Degree of Master of Science in Systems Engineering Justine D. Jeroski, BS...electrodes (right). ...................................................... 14 Figure A 3. BIOPAC © hardware system showing placement of ECG

  7. A Wearable Context-Aware ECG Monitoring System Integrated with Built-in Kinematic Sensors of the Smartphone.

    PubMed

    Miao, Fen; Cheng, Yayu; He, Yi; He, Qingyun; Li, Ye

    2015-05-19

    Continuously monitoring the ECG signals over hours combined with activity status is very important for preventing cardiovascular diseases. A traditional ECG holter is often inconvenient to carry because it has many electrodes attached to the chest and because it is heavy. This work proposes a wearable, low power context-aware ECG monitoring system integrated built-in kinetic sensors of the smartphone with a self-designed ECG sensor. The wearable ECG sensor is comprised of a fully integrated analog front-end (AFE), a commercial micro control unit (MCU), a secure digital (SD) card, and a Bluetooth module. The whole sensor is very small with a size of only 58 × 50 × 10 mm for wearable monitoring application due to the AFE design, and the total power dissipation in a full round of ECG acquisition is only 12.5 mW. With the help of built-in kinetic sensors of the smartphone, the proposed system can compute and recognize user's physical activity, and thus provide context-aware information for the continuous ECG monitoring. The experimental results demonstrated the performance of proposed system in improving diagnosis accuracy for arrhythmias and identifying the most common abnormal ECG patterns in different activities. In conclusion, we provide a wearable, accurate and energy-efficient system for long-term and context-aware ECG monitoring without any extra cost on kinetic sensor design but with the help of the widespread smartphone.

  8. A Novel Automatic Detection System for ECG Arrhythmias Using Maximum Margin Clustering with Immune Evolutionary Algorithm

    PubMed Central

    Zhu, Bohui; Ding, Yongsheng; Hao, Kuangrong

    2013-01-01

    This paper presents a novel maximum margin clustering method with immune evolution (IEMMC) for automatic diagnosis of electrocardiogram (ECG) arrhythmias. This diagnostic system consists of signal processing, feature extraction, and the IEMMC algorithm for clustering of ECG arrhythmias. First, raw ECG signal is processed by an adaptive ECG filter based on wavelet transforms, and waveform of the ECG signal is detected; then, features are extracted from ECG signal to cluster different types of arrhythmias by the IEMMC algorithm. Three types of performance evaluation indicators are used to assess the effect of the IEMMC method for ECG arrhythmias, such as sensitivity, specificity, and accuracy. Compared with K-means and iterSVR algorithms, the IEMMC algorithm reflects better performance not only in clustering result but also in terms of global search ability and convergence ability, which proves its effectiveness for the detection of ECG arrhythmias. PMID:23690875

  9. Low-power analog integrated circuits for wireless ECG acquisition systems.

    PubMed

    Tsai, Tsung-Heng; Hong, Jia-Hua; Wang, Liang-Hung; Lee, Shuenn-Yuh

    2012-09-01

    This paper presents low-power analog ICs for wireless ECG acquisition systems. Considering the power-efficient communication in the body sensor network, the required low-power analog ICs are developed for a healthcare system through miniaturization and system integration. To acquire the ECG signal, a low-power analog front-end system, including an ECG signal acquisition board, an on-chip low-pass filter, and an on-chip successive-approximation analog-to-digital converter for portable ECG detection devices is presented. A quadrature CMOS voltage-controlled oscillator and a 2.4 GHz direct-conversion transmitter with a power amplifier and upconversion mixer are also developed to transmit the ECG signal through wireless communication. In the receiver, a 2.4 GHz fully integrated CMOS RF front end with a low-noise amplifier, differential power splitter, and quadrature mixer based on current-reused folded architecture is proposed. The circuits have been implemented to meet the specifications of the IEEE 802.15.4 2.4 GHz standard. The low-power ICs of the wireless ECG acquisition systems have been fabricated using a 0.18 μm Taiwan Semiconductor Manufacturing Company (TSMC) CMOS standard process. The measured results on the human body reveal that ECG signals can be acquired effectively by the proposed low-power analog front-end ICs.

  10. Motion artifact removal algorithm by ICA for e-bra: a women ECG measurement system

    NASA Astrophysics Data System (ADS)

    Kwon, Hyeokjun; Oh, Sechang; Varadan, Vijay K.

    2013-04-01

    Wearable ECG(ElectroCardioGram) measurement systems have increasingly been developing for people who suffer from CVD(CardioVascular Disease) and have very active lifestyles. Especially, in the case of female CVD patients, several abnormal CVD symptoms are accompanied with CVDs. Therefore, monitoring women's ECG signal is a significant diagnostic method to prevent from sudden heart attack. The E-bra ECG measurement system from our previous work provides more convenient option for women than Holter monitor system. The e-bra system was developed with a motion artifact removal algorithm by using an adaptive filter with LMS(least mean square) and a wandering noise baseline detection algorithm. In this paper, ICA(independent component analysis) algorithms are suggested to remove motion artifact factor for the e-bra system. Firstly, the ICA algorithms are developed with two kinds of statistical theories: Kurtosis, Endropy and evaluated by performing simulations with a ECG signal created by sgolayfilt function of MATLAB, a noise signal including 0.4Hz, 1.1Hz and 1.9Hz, and a weighed vector W estimated by kurtosis or entropy. A correlation value is shown as the degree of similarity between the created ECG signal and the estimated new ECG signal. In the real time E-Bra system, two pseudo signals are extracted by multiplying with a random weighted vector W, the measured ECG signal from E-bra system, and the noise component signal by noise extraction algorithm from our previous work. The suggested ICA algorithm basing on kurtosis or entropy is used to estimate the new ECG signal Y without noise component.

  11. The Development of a Portable ECG Monitor Based on DSP

    NASA Astrophysics Data System (ADS)

    Nan, CHI Jian; Tao, YAN Yan; Meng Chen, LIU; Li, YANG

    With the advent of global information, researches of Smart Home system are in the ascendant, the ECG real-time detection, and wireless transmission of ECG become more useful. In order to achieve the purpose we developed a portable ECG monitor which achieves the purpose of cardiac disease remote monitoring, and will be used in the physical and psychological disease surveillance in smart home system, we developed this portable ECG Monitor, based on the analysis of existing ECG Monitor, using TMS320F2812 as the core controller, which complete the signal collection, storage, processing, waveform display and transmission.

  12. Design of portable electrocardiogram device using DSO138

    NASA Astrophysics Data System (ADS)

    Abuzairi, Tomy; Matondang, Josef Stevanus; Purnamaningsih, Retno Wigajatri; Basari, Ratnasari, Anita

    2018-02-01

    Cardiovascular disease has been one of the leading causes of sudden cardiac deaths in many countries, covering Indonesia. Electrocardiogram (ECG) is a medical test to detect cardiac abnormalities by measuring the electrical activity generated by the heart, as the heart contracts. By using ECG, we can observe anomaly at the time of heart abnormalities. In this paper, design of portable ECG device is presented. The portable ECG device was designed to easily use in the village clinic or houses, due to the small size device and other benefits. The device was designed by using four units: (1) ECG electrode; (2) ECG analog front-end; (3) DSO138; and (4) battery. To create a simple electrode system in the portable ECG, 1-lead ECG with two electrodes were applied. The analog front-end circuitry consists of three integrated circuits, an instrumentation amplifier AD820AN, a low noise operational amplifier OPA134, and a low offset operational amplifier TL082. Digital ECG data were transformed to graphical data on DSO138. The results show that the portable ECG is successfully read the signal from 1-lead ECG system.

  13. A mobile phone-based ECG monitoring system.

    PubMed

    Iwamoto, Junichi; Yonezawa, Yoshiharu; Maki, Hiromichi; Ogawa, Hidekuni; Ninomiya, Ishio; Sada, Kouji; Hamada, Shingo; Hahn, Allen W; Caldwell, W Morton

    2006-01-01

    We have developed a telemedicine system for monitoring a patient's electrocardiogram during daily activities. The recording system consists of three ECG chest electrodes, a variable gain instrumentation amplifier, a low power 8-bit single-chip microcomputer, a 256 KB EEPROM and a 2.4 GHz low transmitting power mobile phone (PHS). The complete system is mounted on a single, lightweight, chest electrode array. When a heart discomfort is felt, the patient pushes the data transmission switch on the recording system. The system sends the recorded ECG waveforms of the two prior minutes and ECG waveforms of the two minutes after the switch is pressed, directly in the hospital server computer via the PHS. The server computer sends the data to the physician on call. The data is displayed on the doctor's Java mobile phone LCD (Liquid Crystal Display), so he or she can monitor the ECG regardless of their location. The developed ECG monitoring system is not only applicable to at-home patients, but should also be useful for monitoring hospital patients.

  14. SPEAR Trial: Smartphone Pediatric ElectrocARdiogram Trial

    PubMed Central

    Nguyen, Hoang H.; Van Hare, George F.; Rudokas, Michael; Bowman, Tammy; Silva, Jennifer N. A.

    2015-01-01

    Objectives Smartphone-enabled ECG devices have the potential to improve patient care by enabling remote ECG assessment of patients with potential and diagnosed arrhythmias. This prospective study aimed to assess the usefulness of pediatric ECG tracings generated by the AliveCor device (Oklahoma City, OK) and to assess user satisfaction. Study Design Enrolled pediatric patients with documented paroxysmal arrhythmia used the AliveCor device over a yearlong study period. Pediatric electrophysiologists reviewed all transmitted ECG tracings. Patient completed surveys were analyzed to assess user satisfaction. Results 35 patients were enrolled with the following diagnoses: supraventricular tachycardia (SVT, 57%), atrial fibrillation (AF, 11%), ectopic atrial tachycardia (EAT, 6%), atrial tachycardia (AT, 3%), and ventricular tachycardia (VT, 23%). A total of 238 tracings were received from 20 patients, 96% of which were of diagnostic quality for sinus rhythm, sinus tachycardia, SVT, and AF. 126 patient satisfaction surveys (64% from parents) were completed. 98% of the survey responses indicated that it was easy to obtain tracings, 93% found it easy to transmit the tracings, 98% showed added comfort in managing arrhythmia by having the device, and 93% showed interest in continued use of the device after the study period ended. Conclusions Smartphone-enabled ECG devices can generate tracings of diagnostic quality in children. User satisfaction was extremely positive. Use of the device to manage certain patients with AF and SVT showcases the future role of remote ECGs in the successful outpatient management of arrhythmias in children by potentially reducing Emergency Department visits and healthcare costs. PMID:26295569

  15. [The primary research and development of software oversampling mapping system for electrocardiogram].

    PubMed

    Zhou, Yu; Ren, Jie

    2011-04-01

    We put forward a new concept of software oversampling mapping system for electrocardiogram (ECG) to assist the research of the ECG inverse problem to improve the generality of mapping system and the quality of mapping signals. We then developed a conceptual system based on the traditional ECG detecting circuit, Labview and DAQ card produced by National Instruments, and at the same time combined the newly-developed oversampling method into the system. The results indicated that the system could map ECG signals accurately and the quality of the signals was good. The improvement of hardware and enhancement of software made the system suitable for mapping in different situations. So the primary development of the software for oversampling mapping system was successful and further research and development can make the system a powerful tool for researching ECG inverse problem.

  16. Low-cost compact ECG with graphic LCD and phonocardiogram system design.

    PubMed

    Kara, Sadik; Kemaloğlu, Semra; Kirbaş, Samil

    2006-06-01

    Till today, many different ECG devices are made in developing countries. In this study, low cost, small size, portable LCD screen ECG device, and phonocardiograph were designed. With designed system, heart sounds that take synchronously with ECG signal are heard as sensitive. Improved system consist three units; Unit 1, ECG circuit, filter and amplifier structure. Unit 2, heart sound acquisition circuit. Unit 3, microcontroller, graphic LCD and ECG signal sending unit to computer. Our system can be used easily in different departments of the hospital, health institution and clinics, village clinic and also in houses because of its small size structure and other benefits. In this way, it is possible that to see ECG signal and hear heart sounds as synchronously and sensitively. In conclusion, heart sounds are heard on the part of both doctor and patient because sounds are given to environment with a tiny speaker. Thus, the patient knows and hears heart sounds him/herself and is acquainted by doctor about healthy condition.

  17. The Abnormal vs. Normal ECG Classification Based on Key Features and Statistical Learning

    NASA Astrophysics Data System (ADS)

    Dong, Jun; Tong, Jia-Fei; Liu, Xia

    As cardiovascular diseases appear frequently in modern society, the medicine and health system should be adjusted to meet the new requirements. Chinese government has planned to establish basic community medical insurance system (BCMIS) before 2020, where remote medical service is one of core issues. Therefore, we have developed the "remote network hospital system" which includes data server and diagnosis terminal by the aid of wireless detector to sample ECG. To improve the efficiency of ECG processing, in this paper, abnormal vs. normal ECG classification approach based on key features and statistical learning is presented, and the results are analyzed. Large amount of normal ECG could be filtered by computer automatically and abnormal ECG is left to be diagnosed specially by physicians.

  18. Design and implementation of a 3-lead ECG wireless remote monitoring system

    NASA Astrophysics Data System (ADS)

    Zhang, Shi; Jia, Xiaonan; Shang, Shuai

    2006-11-01

    Cardiovascular disease is one of the main diseases that menaces human health. It is necessary to monitor the patient's real-time electrocardiograph (ECG) for a long time to realize diagnosis and salvage. Remote ECG monitoring system is the solution. This paper introduces the design and implement of a 3-lead ECG wireless remote monitoring system. It collects, stores and transmits user's ECG which can be received by hospital and diagnosed by doctors. The development of the whole system contains three parts, the hardware and embedded software implementation of MONITOR, software of the MONITORING CENTER, and the routing software of NETWORK CENTER. According to the clinic experimentation, this system has high reliability and utility. There will be great social and economic benefit if this system is put into use.

  19. An IoT-cloud Based Wearable ECG Monitoring System for Smart Healthcare.

    PubMed

    Yang, Zhe; Zhou, Qihao; Lei, Lei; Zheng, Kan; Xiang, Wei

    2016-12-01

    Public healthcare has been paid an increasing attention given the exponential growth human population and medical expenses. It is well known that an effective health monitoring system can detect abnormalities of health conditions in time and make diagnoses according to the gleaned data. As a vital approach to diagnose heart diseases, ECG monitoring is widely studied and applied. However, nearly all existing portable ECG monitoring systems cannot work without a mobile application, which is responsible for data collection and display. In this paper, we propose a new method for ECG monitoring based on Internet-of-Things (IoT) techniques. ECG data are gathered using a wearable monitoring node and are transmitted directly to the IoT cloud using Wi-Fi. Both the HTTP and MQTT protocols are employed in the IoT cloud in order to provide visual and timely ECG data to users. Nearly all smart terminals with a web browser can acquire ECG data conveniently, which has greatly alleviated the cross-platform issue. Experiments are carried out on healthy volunteers in order to verify the reliability of the entire system. Experimental results reveal that the proposed system is reliable in collecting and displaying real-time ECG data, which can aid in the primary diagnosis of certain heart diseases.

  20. Flexible Graphene Electrodes for Prolonged Dynamic ECG Monitoring

    PubMed Central

    Lou, Cunguang; Li, Ruikai; Li, Zhaopeng; Liang, Tie; Wei, Zihui; Run, Mingtao; Yan, Xiaobing; Liu, Xiuling

    2016-01-01

    This paper describes the development of a graphene-based dry flexible electrocardiography (ECG) electrode and a portable wireless ECG measurement system. First, graphene films on polyethylene terephthalate (PET) substrates and graphene paper were used to construct the ECG electrode. Then, a graphene textile was synthesized for the fabrication of a wearable ECG monitoring system. The structure and the electrical properties of the graphene electrodes were evaluated using Raman spectroscopy, scanning electron microscopy (SEM), and alternating current impedance spectroscopy. ECG signals were then collected from healthy subjects using the developed graphene electrode and portable measurement system. The results show that the graphene electrode was able to acquire the typical characteristics and features of human ECG signals with a high signal-to-noise (SNR) ratio in different states of motion. A week-long continuous wearability test showed no degradation in the ECG signal quality over time. The graphene-based flexible electrode demonstrates comfortability, good biocompatibility, and high electrophysiological detection sensitivity. The graphene electrode also combines the potential for use in long-term wearable dynamic cardiac activity monitoring systems with convenience and comfort for use in home health care of elderly and high-risk adults. PMID:27809270

  1. Ambulatory ECG monitoring in atrial fibrillation management.

    PubMed

    Rosero, Spencer Z; Kutyifa, Valentina; Olshansky, Brian; Zareba, Wojciech

    2013-01-01

    Ambulatory ECG monitoring technology has rapidly evolved over the last few decades and has been shown to identify life-threatening and non-life threatening arrhythmias and provide actionable data to guide clinical decision making. Atrial fibrillation episodes can often be asymptomatic, even after catheter ablation for atrial fibrillation, creating a disconnect between symptoms and actual arrhythmia burden which may alter clinical management. In this review, we aim to provide a comprehensive overview of invasive and non-invasive ECG monitoring strategies in patients with atrial fibrillation, with a special focus on the diagnosis of atrial fibrillation, and on follow-up of patients after catheter ablation for atrial fibrillation ablation. © 2013.

  2. III Lead ECG Pulse Measurement Sensor

    NASA Astrophysics Data System (ADS)

    Thangaraju, S. K.; Munisamy, K.

    2015-09-01

    Heart rate sensing is very important. Method of measuring heart pulse by using an electrocardiogram (ECG) technique is described. Electrocardiogram is a measurement of the potential difference (the electrical pulse) generated by a cardiac tissue, mainly the heart. This paper also reports the development of a three lead ECG hardware system that would be the basis of developing a more cost efficient, portable and easy to use ECG machine. Einthoven's Three Lead method [1] is used for ECG signal extraction. Using amplifiers such as the instrumentation amplifier AD620BN and the conventional operational amplifier Ua741 that would be used to amplify the ECG signal extracted develop this system. The signal would then be filtered from noise using Butterworth filter techniques to obtain optimum output. Also a right leg guard was implemented as a safety feature to this system. Simulation was carried out for development of the system using P-spice Program.

  3. A Primary Study of Indirect ECG Monitor Embedded in a Bed for Home Health Care

    NASA Astrophysics Data System (ADS)

    Ueno, Akinori; Shiogai, Yuuki; Ishiyama, Yoji

    A system for monitoring electrocardiogram (ECG) through clothes inserted between the measuring electrodes and the body surface of a subject when lying on a mattress has been proposed. The principle of the system is based on capacitive coupling involving the electrode, the clothes, and the skin. Validation of the system revealed the following: (1) In spite of the gain attenuation in the pass band of the system, distortion of the detected signal was subtle even when clothes thicker than 1mm were inserted, (2) The system was able to yield a stable ECG from a subject particularly during sound sleep, (3) The system succeeded in detecting ECG after changing the posture into any of supine, right lateral, or left lateral positions by adopting a newly devised electrode configuration. Therefore, the proposed system appears promising for application to bedding as a non-invasive and awareness-free system for ECG monitoring during sleep.

  4. Near Field Communication-based telemonitoring with integrated ECG recordings.

    PubMed

    Morak, J; Kumpusch, H; Hayn, D; Leitner, M; Scherr, D; Fruhwald, F M; Schreier, G

    2011-01-01

    Telemonitoring of vital signs is an established option in treatment of patients with chronic heart failure (CHF). In order to allow for early detection of atrial fibrillation (AF) which is highly prevalent in the CHF population telemonitoring programs should include electrocardiogram (ECG) signals. It was therefore the aim to extend our current home monitoring system based on mobile phones and Near Field Communication technology (NFC) to enable patients acquiring their ECG signals autonomously in an easy-to-use way. We prototypically developed a sensing device for the concurrent acquisition of blood pressure and ECG signals. The design of the device equipped with NFC technology and Bluetooth allowed for intuitive interaction with a mobile phone based patient terminal. This ECG monitoring system was evaluated in the course of a clinical pilot trial to assess the system's technical feasibility, usability and patient's adherence to twice daily usage. 21 patients (4f, 54 ± 14 years) suffering from CHF were included in the study and were asked to transmit two ECG recordings per day via the telemonitoring system autonomously over a monitoring period of seven days. One patient dropped out from the study. 211 data sets were transmitted over a cumulative monitoring period of 140 days (overall adherence rate 82.2%). 55% and 8% of the transmitted ECG signals were sufficient for ventricular and atrial rhythm assessment, respectively. Although ECG signal quality has to be improved for better AF detection the developed communication design of joining Bluetooth and NFC technology in our telemonitoring system allows for ambulatory ECG acquisition with high adherence rates and system usability in heart failure patients.

  5. Assessment of Remote Heart Rhythm Sampling Using the AliveCor Heart Monitor to Screen for Atrial Fibrillation: The REHEARSE-AF Study.

    PubMed

    Halcox, Julian P J; Wareham, Kathie; Cardew, Antonia; Gilmore, Mark; Barry, James P; Phillips, Ceri; Gravenor, Michael B

    2017-11-07

    Asymptomatic atrial fibrillation (AF) is increasingly common in the aging population and implicated in many ischemic strokes. Earlier identification of AF with appropriate anticoagulation may decrease stroke morbidity and mortality. We conducted a randomized controlled trial of AF screening using an AliveCor Kardia monitor attached to a WiFi-enabled iPod to obtain ECGs (iECGs) in ambulatory patients. Patients ≥65 years of age with a CHADS-VASc score ≥2 free from AF were randomized to the iECG arm or routine care (RC). iECG participants acquired iECGs twice weekly over 12 months (plus additional iECGs if symptomatic) onto a secure study server with overread by an automated AF detection algorithm and by a cardiac physiologist and/or consultant cardiologist. Time to diagnosis of AF was the primary outcome measure. The overall cost of the devices, ECG interpretation, and patient management were captured and used to generate the cost per AF diagnosis in iECG patients. Clinical events and patient attitudes/experience were also evaluated. We studied 1001 patients (500 iECG, 501 RC) who were 72.6±5.4 years of age; 534 were female. Mean CHADS-VASc score was 3.0 (heart failure, 1.4%; hypertension, 54%; diabetes mellitus, 30%; prior stroke/transient ischemic attack, 6.5%; arterial disease, 15.9%; all CHADS-VASc risk factors were evenly distributed between groups). Nineteen patients in the iECG group were diagnosed with AF over the 12-month study period versus 5 in the RC arm (hazard ratio, 3.9; 95% confidence interval=1.4-10.4; P =0.007) at a cost per AF diagnosis of $10 780 (£8255). There was a similar number of stroke/transient ischemic attack/systemic embolic events (6 versus 10, iECG versus RC; hazard ratio=0.61; 95% confidence interval=0.22-1.69; P =0.34). The majority of iECG patients were satisfied with the device, finding it easy to use without restricting activities or causing anxiety. Screening with twice-weekly single-lead iECG with remote interpretation in ambulatory patients ≥65 years of age at increased risk of stroke is significantly more likely to identify incident AF than RC over a 12-month period. This approach is also highly acceptable to this group of patients, supporting further evaluation in an appropriately powered, event-driven clinical trial. URL: https://www.isrctn.com. Unique identifier: ISRCTN10709813. © 2017 American Heart Association, Inc.

  6. A novel biometric authentication approach using ECG and EMG signals.

    PubMed

    Belgacem, Noureddine; Fournier, Régis; Nait-Ali, Amine; Bereksi-Reguig, Fethi

    2015-05-01

    Security biometrics is a secure alternative to traditional methods of identity verification of individuals, such as authentication systems based on user name and password. Recently, it has been found that the electrocardiogram (ECG) signal formed by five successive waves (P, Q, R, S and T) is unique to each individual. In fact, better than any other biometrics' measures, it delivers proof of subject's being alive as extra information which other biometrics cannot deliver. The main purpose of this work is to present a low-cost method for online acquisition and processing of ECG signals for person authentication and to study the possibility of providing additional information and retrieve personal data from an electrocardiogram signal to yield a reliable decision. This study explores the effectiveness of a novel biometric system resulting from the fusion of information and knowledge provided by ECG and EMG (Electromyogram) physiological recordings. It is shown that biometrics based on these ECG/EMG signals offers a novel way to robustly authenticate subjects. Five ECG databases (MIT-BIH, ST-T, NSR, PTB and ECG-ID) and several ECG signals collected in-house from volunteers were exploited. A palm-based ECG biometric system was developed where the signals are collected from the palm of the subject through a minimally intrusive one-lead ECG set-up. A total of 3750 ECG beats were used in this work. Feature extraction was performed on ECG signals using Fourier descriptors (spectral coefficients). Optimum-Path Forest classifier was used to calculate the degree of similarity between individuals. The obtained results from the proposed approach look promising for individuals' authentication.

  7. ANMCO/AIIC/SIT Consensus Information Document: definition, precision, and suitability of electrocardiographic signals of electrocardiographs, ergometry, Holter electrocardiogram, telemetry, and bedside monitoring systems.

    PubMed

    Gulizia, Michele Massimo; Casolo, Giancarlo; Zuin, Guerrino; Morichelli, Loredana; Calcagnini, Giovanni; Ventimiglia, Vincenzo; Censi, Federica; Caldarola, Pasquale; Russo, Giancarmine; Leogrande, Lorenzo; Franco Gensini, Gian

    2017-05-01

    The electrocardiogram (ECG) signal can be derived from different sources. These include systems for surface ECG, Holter monitoring, ergometric stress tests, and telemetry systems and bedside monitoring of vital parameters, which are useful for rhythm and ST-segment analysis and ECG screening of electrical sudden cardiac death predictors. A precise ECG diagnosis is based upon correct recording, elaboration, and presentation of the signal. Several sources of artefacts and potential external causes may influence the quality of the original ECG waveforms. Other factors that may affect the quality of the information presented depend upon the technical solutions employed to improve the signal. The choice of the instrumentations and solutions used to offer a high-quality ECG signal are, therefore, of paramount importance. Some requirements are reported in detail in scientific statements and recommendations. The aim of this consensus document is to give scientific reference for the choice of systems able to offer high quality ECG signal acquisition, processing, and presentation suitable for clinical use.

  8. ANMCO/AIIC/SIT Consensus Information Document: definition, precision, and suitability of electrocardiographic signals of electrocardiographs, ergometry, Holter electrocardiogram, telemetry, and bedside monitoring systems

    PubMed Central

    Casolo, Giancarlo; Zuin, Guerrino; Morichelli, Loredana; Calcagnini, Giovanni; Ventimiglia, Vincenzo; Censi, Federica; Caldarola, Pasquale; Russo, Giancarmine; Leogrande, Lorenzo; Franco Gensini, Gian

    2017-01-01

    Abstract The electrocardiogram (ECG) signal can be derived from different sources. These include systems for surface ECG, Holter monitoring, ergometric stress tests, and telemetry systems and bedside monitoring of vital parameters, which are useful for rhythm and ST-segment analysis and ECG screening of electrical sudden cardiac death predictors. A precise ECG diagnosis is based upon correct recording, elaboration, and presentation of the signal. Several sources of artefacts and potential external causes may influence the quality of the original ECG waveforms. Other factors that may affect the quality of the information presented depend upon the technical solutions employed to improve the signal. The choice of the instrumentations and solutions used to offer a high-quality ECG signal are, therefore, of paramount importance. Some requirements are reported in detail in scientific statements and recommendations. The aim of this consensus document is to give scientific reference for the choice of systems able to offer high quality ECG signal acquisition, processing, and presentation suitable for clinical use. PMID:28751842

  9. A web-based approach for electrocardiogram monitoring in the home.

    PubMed

    Magrabi, F; Lovell, N H; Celler, B G

    1999-05-01

    A Web-based electrocardiogram (ECG) monitoring service in which a longitudinal clinical record is used for management of patients, is described. The Web application is used to collect clinical data from the patient's home. A database on the server acts as a central repository where this clinical information is stored. A Web browser provides access to the patient's records and ECG data. We discuss the technologies used to automate the retrieval and storage of clinical data from a patient database, and the recording and reviewing of clinical measurement data. On the client's Web browser, ActiveX controls embedded in the Web pages provide a link between the various components including the Web server, Web page, the specialised client side ECG review and acquisition software, and the local file system. The ActiveX controls also implement FTP functions to retrieve and submit clinical data to and from the server. An intelligent software agent on the server is activated whenever new ECG data is sent from the home. The agent compares historical data with newly acquired data. Using this method, an optimum patient care strategy can be evaluated, a summarised report along with reminders and suggestions for action is sent to the doctor and patient by email.

  10. Open source cardiology electronic health record development for DIGICARDIAC implementation

    NASA Astrophysics Data System (ADS)

    Dugarte, Nelson; Medina, Rubén.; Huiracocha, Lourdes; Rojas, Rubén.

    2015-12-01

    This article presents the development of a Cardiology Electronic Health Record (CEHR) system. Software consists of a structured algorithm designed under Health Level-7 (HL7) international standards. Novelty of the system is the integration of high resolution ECG (HRECG) signal acquisition and processing tools, patient information management tools and telecardiology tools. Acquisition tools are for management and control of the DIGICARDIAC electrocardiograph functions. Processing tools allow management of HRECG signal analysis searching for indicative patterns of cardiovascular pathologies. Telecardiology tools incorporation allows system communication with other health care centers decreasing access time to the patient information. CEHR system was completely developed using open source software. Preliminary results of process validation showed the system efficiency.

  11. Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System

    PubMed Central

    Kwon, Sungjun; Lee, Dongseok; Kim, Jeehoon; Lee, Youngki; Kang, Seungwoo; Seo, Sangwon; Park, Kwangsuk

    2016-01-01

    In our preliminary study, we proposed a smartphone-integrated, unobtrusive electrocardiogram (ECG) monitoring system, Sinabro, which monitors a user’s ECG opportunistically during daily smartphone use without explicit user intervention. The proposed system also monitors ECG-derived features, such as heart rate (HR) and heart rate variability (HRV), to support the pervasive healthcare apps for smartphones based on the user’s high-level contexts, such as stress and affective state levels. In this study, we have extended the Sinabro system by: (1) upgrading the sensor device; (2) improving the feature extraction process; and (3) evaluating extensions of the system. We evaluated these extensions with a good set of algorithm parameters that were suggested based on empirical analyses. The results showed that the system could capture ECG reliably and extract highly accurate ECG-derived features with a reasonable rate of data drop during the user’s daily smartphone use. PMID:26978364

  12. Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System.

    PubMed

    Kwon, Sungjun; Lee, Dongseok; Kim, Jeehoon; Lee, Youngki; Kang, Seungwoo; Seo, Sangwon; Park, Kwangsuk

    2016-03-11

    In our preliminary study, we proposed a smartphone-integrated, unobtrusive electrocardiogram (ECG) monitoring system, Sinabro, which monitors a user's ECG opportunistically during daily smartphone use without explicit user intervention. The proposed system also monitors ECG-derived features, such as heart rate (HR) and heart rate variability (HRV), to support the pervasive healthcare apps for smartphones based on the user's high-level contexts, such as stress and affective state levels. In this study, we have extended the Sinabro system by: (1) upgrading the sensor device; (2) improving the feature extraction process; and (3) evaluating extensions of the system. We evaluated these extensions with a good set of algorithm parameters that were suggested based on empirical analyses. The results showed that the system could capture ECG reliably and extract highly accurate ECG-derived features with a reasonable rate of data drop during the user's daily smartphone use.

  13. XML-BSPM: an XML format for storing Body Surface Potential Map recordings.

    PubMed

    Bond, Raymond R; Finlay, Dewar D; Nugent, Chris D; Moore, George

    2010-05-14

    The Body Surface Potential Map (BSPM) is an electrocardiographic method, for recording and displaying the electrical activity of the heart, from a spatial perspective. The BSPM has been deemed more accurate for assessing certain cardiac pathologies when compared to the 12-lead ECG. Nevertheless, the 12-lead ECG remains the most popular ECG acquisition method for non-invasively assessing the electrical activity of the heart. Although data from the 12-lead ECG can be stored and shared using open formats such as SCP-ECG, no open formats currently exist for storing and sharing the BSPM. As a result, an innovative format for storing BSPM datasets has been developed within this study. The XML vocabulary was chosen for implementation, as opposed to binary for the purpose of human readability. There are currently no standards to dictate the number of electrodes and electrode positions for recording a BSPM. In fact, there are at least 11 different BSPM electrode configurations in use today. Therefore, in order to support these BSPM variants, the XML-BSPM format was made versatile. Hence, the format supports the storage of custom torso diagrams using SVG graphics. This diagram can then be used in a 2D coordinate system for retaining electrode positions. This XML-BSPM format has been successfully used to store the Kornreich-117 BSPM dataset and the Lux-192 BSPM dataset. The resulting file sizes were in the region of 277 kilobytes for each BSPM recording and can be deemed suitable for example, for use with any telemonitoring application. Moreover, there is potential for file sizes to be further reduced using basic compression algorithms, i.e. the deflate algorithm. Finally, these BSPM files have been parsed and visualised within a convenient time period using a web based BSPM viewer. This format, if widely adopted could promote BSPM interoperability, knowledge sharing and data mining. This work could also be used to provide conceptual solutions and inspire existing formats such as DICOM, SCP-ECG and aECG to support the storage of BSPMs. In summary, this research provides initial ground work for creating a complete BSPM management system.

  14. [Study for portable dynamic ECG monitor and recorder].

    PubMed

    Yang, Pengcheng; Li, Yongqin; Chen, Bihua

    2012-09-01

    This Paper presents a portable dynamic ECG monitor system based on MSP430F149 microcontroller. The electrocardiogram detecting system consists of ECG detecting circuit, man-machine interaction module, MSP430F149 and upper computer software. The ECG detecting circuit including a preamplifier, second-order Butterworth low-pass filter, high-pass filter, and 50Hz trap circuit to detects electrocardiogram and depresses various kinds of interference effectively. A microcontroller is used to collect three channel analog signals which can be displayed on TFT LCD. A SD card is used to record real-time data continuously and implement the FTA16 file system. In the end, a host computer system interface is also designed to analyze the ECG signal and the analysis results can provide diagnosis references to clinical doctors.

  15. Noninvasive fetal electrocardiography following intermittent umbilical cord occlusion in the preterm ovine fetus.

    PubMed

    Cleal, J K; Thomas, M; Hanson, M A; Paterson-Brown, S; Gardiner, H M; Green, L R

    2010-03-01

    To investigate whether a noninvasive fetal electrocardiography (fECG) system can identify cardiovascular responses to fetal hypoxaemia and validate the results using standard invasive fECG monitoring techniques. Prospective cohort study. Biological research facilities at The University of Southampton. Late gestation ovine fetuses; n = 5. Five fetal lambs underwent implantation of vascular catheters, umbilical cord occluder and invasive ECG chest electrodes under general anaesthesia (3% halothane/O(2)) at 119 days of gestation (term approximately 147 days of gestation). After 5 days of recovery blood pressure, blood gases, glucose and pH were monitored. At 124 and 125 days of gestation following a 10-minute baseline period a 90-second cord occlusion was applied. Noninvasive fetal ECG was recorded from maternal transabdominal electrodes using advanced signal-processing techniques, concurrently with invasive fECG recordings. Comparison of T:QRS ratios of the ECG waveform from noninvasive and invasive fECG monitoring systems. Our fECG monitoring system is able to demonstrate changes in waveforms during periods of hypoxaemia similar to those obtained invasively, which could indicate fetal distress. These findings may indicate a future use for noninvasive electrocardiography during human fetal monitoring both before and during labour in term and preterm pregnancies.

  16. PIC microcontroller-based RF wireless ECG monitoring system.

    PubMed

    Oweis, R J; Barhoum, A

    2007-01-01

    This paper presents a radio-telemetry system that provides the possibility of ECG signal transmission from a patient detection circuit via an RF data link. A PC then receives the signal through the National Instrument data acquisition card (NIDAQ). The PC is equipped with software allowing the received ECG signals to be saved, analysed, and sent by email to another part of the world. The proposed telemetry system consists of a patient unit and a PC unit. The amplified and filtered ECG signal is sampled 360 times per second, and the A/D conversion is performed by a PIC16f877 microcontroller. The major contribution of the final proposed system is that it detects, processes and sends patients ECG data over a wireless RF link to a maximum distance of 200 m. Transmitted ECG data with different numbers of samples were received, decoded by means of another PIC microcontroller, and displayed using MATLAB program. The designed software is presented in a graphical user interface utility.

  17. Implementation of a wireless ECG acquisition SoC for IEEE 802.15.4 (ZigBee) applications.

    PubMed

    Wang, Liang-Hung; Chen, Tsung-Yen; Lin, Kuang-Hao; Fang, Qiang; Lee, Shuenn-Yuh

    2015-01-01

    This paper presents a wireless biosignal acquisition system-on-a-chip (WBSA-SoC) specialized for electrocardiogram (ECG) monitoring. The proposed system consists of three subsystems, namely, 1) the ECG acquisition node, 2) the protocol for standard IEEE 802.15.4 ZigBee system, and 3) the RF transmitter circuits. The ZigBee protocol is adopted for wireless communication to achieve high integration, applicability, and portability. A fully integrated CMOS RF front end containing a quadrature voltage-controlled oscillator and a 2.4-GHz low-IF (i.e., zero-IF) transmitter is employed to transmit ECG signals through wireless communication. The low-power WBSA-SoC is implemented by the TSMC 0.18-μm standard CMOS process. An ARM-based displayer with FPGA demodulation and an RF receiver with analog-to-digital mixed-mode circuits are constructed as verification platform to demonstrate the wireless ECG acquisition system. Measurement results on the human body show that the proposed SoC can effectively acquire ECG signals.

  18. Management of coronary artery disease

    NASA Astrophysics Data System (ADS)

    Safri, Z.

    2018-03-01

    Coronary Artery Disease (CAD) is associated with significant morbidity and mortality, therefore it’s important to early and accurate detection and appropriate management. Diagnosis of CAD include clinical examination, noninvasive techniques such as biochemical testing, a resting ECG, possibly ambulatory ECG monitoring, resting echocardiography, chest X-ray in selected patients; and catheterization. Managements of CAD patients include lifestyle modification, control of CAD risk factors, pharmacologic therapy, and patient education. Revascularization consists of percutaneous coronary angioplasty and coronary artery bypass grafting. Cardiac rehabilitation should be considered in all patients with CAD. This comprehensive review highlights strategies of management in patients with CAD.

  19. A Novel Tool for Assessment of Emergency Medicine Resident Skill in Determining Diagnosis and Management for Emergent Electrocardiograms: A Multicenter Study.

    PubMed

    Hartman, Nicholas D; Wheaton, Natasha B; Williamson, Kelly; Quattromani, Erin N; Branzetti, Jeremy B; Aldeen, Amer Z

    2016-12-01

    Reading emergent electrocardiograms (ECGs) is one of the emergency physician's most crucial tasks, yet no well-validated tool exists to measure resident competence in this skill. To assess validity of a novel tool measuring emergency medicine resident competency for interpreting, and responding to, critical ECGs. In addition, we aim to observe trends in this skill for resident physicians at different levels of training. This is a multi-center, prospective study of postgraduate year (PGY) 1-4 residents at five emergency medicine (EM) residency programs in the United States. An assessment tool was created that asks the physician to identify either the ECG diagnosis or the best immediate management. One hundred thirteen EM residents from five EM residency programs submitted completed assessment surveys, including 43 PGY-1s, 33 PGY-2s, and 37 PGY-3/4s. PGY-3/4s averaged 74.6% correct (95% confidence interval [CI] 70.9-78.4) and performed significantly better than PGY-1s, who averaged 63.2% correct (95% CI 58.0-68.3). PGY-2s averaged 69.0% (95% CI 62.2-73.7). Year-to-year differences were more pronounced in management than in diagnosis. Residency training in EM seems to be associated with improved ability to interpret "critical" ECGs as measured by our assessment tool. This lends validity evidence for the tool by correlating with a previously observed association between residency training and improved ECG interpretation. Resident skill in ECG interpretation remains less than ideal. Creation of this sort of tool may allow programs to assess resident performance as well as evaluate interventions designed to improve competency. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Cost-effectiveness analysis of computerized ECG interpretation system in an ambulatory health care organization.

    PubMed

    Carel, R S

    1982-04-01

    The cost-effectiveness of a computerized ECG interpretation system in an ambulatory health care organization has been evaluated in comparison with a conventional (manual) system. The automated system was shown to be more cost-effective at a minimum load of 2,500 patients/month. At larger monthly loads an even greater cost-effectiveness was found, the average cost/ECG being about $2. In the manual system the cost/unit is practically independent of patient load. This is primarily due to the fact that 87% of the cost/ECG is attributable to wages and fees of highly trained personnel. In the automated system, on the other hand, the cost/ECG is heavily dependent on examinee load. This is due to the relatively large impact of equipment depreciation on fixed (and total) cost. Utilization of a computer-assisted system leads to marked reduction in cardiologists' interpretation time, substantially shorter turnaround time (of unconfirmed reports), and potential provision of simultaneous service at several remotely located "heart stations."

  1. Near Field Communication-based telemonitoring with integrated ECG recordings

    PubMed Central

    Morak, J.; Kumpusch, H.; Hayn, D.; Leitner, M.; Scherr, D.; Fruhwald, F.M.; Schreier, G.

    2011-01-01

    Objectives Telemonitoring of vital signs is an established option in treatment of patients with chronic heart failure (CHF). In order to allow for early detection of atrial fibrillation (AF) which is highly prevalent in the CHF population telemonitoring programs should include electrocardiogram (ECG) signals. It was therefore the aim to extend our current home monitoring system based on mobile phones and Near Field Communication technology (NFC) to enable patients acquiring their ECG signals autonomously in an easy-to-use way. Methods We prototypically developed a sensing device for the concurrent acquisition of blood pressure and ECG signals. The design of the device equipped with NFC technology and Bluetooth allowed for intuitive interaction with a mobile phone based patient terminal. This ECG monitoring system was evaluated in the course of a clinical pilot trial to assess the system’s technical feasibility, usability and patient’s adherence to twice daily usage. Results 21 patients (4f, 54 ± 14 years) suffering from CHF were included in the study and were asked to transmit two ECG recordings per day via the telemonitoring system autonomously over a monitoring period of seven days. One patient dropped out from the study. 211 data sets were transmitted over a cumulative monitoring period of 140 days (overall adherence rate 82.2%). 55% and 8% of the transmitted ECG signals were sufficient for ventricular and atrial rhythm assessment, respectively. Conclusions Although ECG signal quality has to be improved for better AF detection the developed communication design of joining Bluetooth and NFC technology in our telemonitoring system allows for ambulatory ECG acquisition with high adherence rates and system usability in heart failure patients. PMID:23616890

  2. Microprocessor Based Real-Time Monitoring of Multiple ECG Signals

    PubMed Central

    Nasipuri, M.; Basu, D.K.; Dattagupta, R.; Kundu, M.; Banerjee, S.

    1987-01-01

    A microprocessor based system capable of realtime monitoring of multiple ECG signals has been described. The system consists of a number of microprocessors connected in a hierarchical fashion and capable of working concurrently on ECG data collected from different channels. The system can monitor different arrhythmic abnormalities for at least 36 patients even for a heart rate of 500 beats/min.

  3. An ultra-high input impedance ECG amplifier for long-term monitoring of athletes.

    PubMed

    Gargiulo, Gaetano; Bifulco, Paolo; Cesarelli, Mario; Ruffo, Mariano; Romano, Maria; Calvo, Rafael A; Jin, Craig; van Schaik, André

    2010-01-01

    We present a new, low-power electrocardiogram (ECG) recording system with an ultra-high input impedance that enables the use of long-lasting, dry electrodes. The system incorporates a low-power Bluetooth module for wireless connectivity and is designed to be suitable for long-term monitoring during daily activities. The new system using dry electrodes was compared with a clinically approved ECG reference system using gelled Ag/AgCl electrodes and performance was found to be equivalent. In addition, the system was used to monitor an athlete during several physical tasks, and a good quality ECG was obtained in all cases, including when the athlete was totally submerged in fresh water.

  4. A Low-Voltage Chopper-Stabilized Amplifier for Fetal ECG Monitoring With a 1.41 Power Efficiency Factor.

    PubMed

    Song, Shuang; Rooijakkers, Michael; Harpe, Pieter; Rabotti, Chiara; Mischi, Massimo; van Roermund, Arthur H M; Cantatore, Eugenio

    2015-04-01

    This paper presents a low-voltage current-reuse chopper-stabilized frontend amplifier for fetal ECG monitoring. The proposed amplifier allows for individual tuning of the noise in each measurement channel, minimizing the total power consumption while satisfying all application requirements. The low-voltage current reuse topology exploits power optimization in both the current and the voltage domain, exploiting multiple supply voltages (0.3, 0.6 and 1.2 V). The power management circuitry providing the different supplies is optimized for high efficiency (peak charge-pump efficiency = 90%).The low-voltage amplifier together with its power management circuitry is implemented in a standard 0.18 μm CMOS process and characterized experimentally. The amplifier core achieves both good noise efficiency factor (NEF=1.74) and power efficiency factor (PEF=1.05). Experiments show that the amplifier core can provide a noise level of 0.34 μVrms in a 0.7 to 182 Hz band, consuming 1.17 μW power. The amplifier together with its power management circuitry consumes 1.56 μW, achieving a PEF of 1.41. The amplifier is also validated with adult ECG and pre-recorded fetal ECG measurements.

  5. E-Bra system for women ECG measurement with GPRS communication, Nanosensor, and motion artifact remove algorithm

    NASA Astrophysics Data System (ADS)

    Kwon, Hyeokjun; Oh, Sechang; Kumar, Prashanth S.; Varadan, Vijay K.

    2012-10-01

    CardioVascular Disease(CVD)s lead the sudden cardiac death due to irregular phenomenon of the cardiac signal by the abnormal case of blood vessel and cardiac structure. For last two decades, cardiac disease research for man is under active discussion. As a result, the death rate by cardiac disease in men has been falling gradually compared with relatively increasing the women death rate due to CVD[2]. The main reason of this phenomenon causes the lack a sense of the seriousness to female CVD and different symptom of female CVD compared with the symptoms of male CVD. Usually, because the women CVD accompanies with ordinary symptoms unrecognizing the heart abnormality signal such as unusual fatigue, sleep disturbances, shortness of breath, anxiety, chest discomfort, and indigestion dyspepsia, most women CVD patients do not realize that these symptoms are related to the CVD symptoms. Therefore, periodic ECG signal observation is required for women cardiac disease patients. ElectroCardioGram(ECG) detection, treadmill test/exercise ECG, nuclear scan, coronary angiography, and intracoronary ultrasound are used to diagnose abnormality of heart. Among the medical checkup methods for CVDs checkup, it is very effective method for the diagnosis of cardiac disease and the early detection of heart abnormality to monitor ECG periodically. This paper suggests the effective ECG monitoring system for woman by attaching the system on woman's brassiere by using augmented chest lead attachment method. The suggested system in this paper consists of ECG signal transmission system and a server program to display and analyze the transmitted ECG. The ECG signal transmission system consists of three parts such as ECG physical signal detection part with two electrodes made by gold nanowire structure, data acquisition with AD converter, and data transmission part with GPRS(General Packet Radio Service) communication. Usually, to detect human bio signal, Ag/AgCl or gold cup electrodes are used with conductive gel. However, the gel can be dried when taking long time monitoring. The gold nanowire structure electrodes without consideration of uncomfortable usage of gel are attached on beneath the chest position of a brassiere, and the electrodes convert the physical ECG signal to voltage potential signal. The voltage potential ECG signal is converted to digital signal by AD converter included in microprocessor. The converted ECG signal by AD converter is saved on every 1 sec period in the internal RAM in microprocessor. For transmission of the saved data in the internal RAM to a server computer locating at remote area, the system uses the GPRS communication technology, which can develop the wide area network(WAP) without any gateway and repeater. In addition, the transmission system is operated on client mode of GPRS communication. The remote server is installed a program including the functions of displaying and analyzing the transmitted ECG. To display the ECG data, the program is operated with TCP/IP server mode and static IP address, and to analyze the ECG data, the paper suggests motion artifact remove algorithm including adaptive filter with LMS(least mean square), baseline detection algorithm using predictability estimation theory, a filter with moving weighted factor, low pass filter, peak to peak detection, and interpolation.

  6. Cardiac investigation in patients with diabetes.

    PubMed

    Tardif, Jean-Claude

    2006-02-01

    Most patients with type 2 diabetes die from heart disease. Screening for the presence of myocardial ischemia is of clinical importance in the management of this population. The pain response to ischemia can be either absent or blunted in diabetes, resulting in the absence of symptoms or an atypical presentation. Exercise electrocardiogram (ECG) should be the initial test in men who are able to exercise and have a normal resting ECG. Stress cardiac imaging should be the initial test in diabetic men with an abnormal resting ECG or who are not able to exercise. More widespread use of cardiac imaging is probably justified in diabetic women and patients with suspected coronary artery disease. Official guidelines for appropriate and cost-effective cardiac investigation should help physicians manage diabetic patients.

  7. A review on digital ECG formats and the relationships between them.

    PubMed

    Trigo, Jesús Daniel; Alesanco, Alvaro; Martínez, Ignacio; García, José

    2012-05-01

    A plethora of digital ECG formats have been proposed and implemented. This heterogeneity hinders the design and development of interoperable systems and entails critical integration issues for the healthcare information systems. This paper aims at performing a comprehensive overview on the current state of affairs of the interoperable exchange of digital ECG signals. This includes 1) a review on existing digital ECG formats, 2) a collection of applications and cardiology settings using such formats, 3) a compilation of the relationships between such formats, and 4) a reflection on the current situation and foreseeable future of the interoperable exchange of digital ECG signals. The objectives have been approached by completing and updating previous reviews on the topic through appropriate database mining. 39 digital ECG formats, 56 applications, tools or implantation experiences, 47 mappings/converters, and 6 relationships between such formats have been found in the literature. The creation and generalization of a single standardized ECG format is a desirable goal. However, this unification requires political commitment and international cooperation among different standardization bodies. Ongoing ontology-based approaches covering ECG domain have recently emerged as a promising alternative for reaching fully fledged ECG interoperability in the near future.

  8. A compact ECG R-R interval, respiration and activity recording system.

    PubMed

    Yoshimura, Takahiro; Yonezawa, Yoshiharu; Maki, Hiromichi; Ogawa, Hidekuni; Hahn, Allen W; Thayer, Julian F; Caldwell, W Morton

    2003-01-01

    An ECG R-R interval, respiration and activity recording system has been developed for monitoring variability of heart rate and respiratory frequency during daily life. The recording system employs a variable gain instrumentation amplifier, an accelerometer, a low power 8-bit single-chip microcomputer and a 1024 KB EEPROM. It is constructed on three ECG chest electrodes. The R-R interval and respiration are detected from the ECG. Activity during walking and running is calculated from an accelerator. The detected data are stored in an EEPROM and after recording, are downloaded to a desktop computer for analysis.

  9. Development and significance of a fetal electrocardiogram recorded by signal-averaged high-amplification electrocardiography.

    PubMed

    Hayashi, Risa; Nakai, Kenji; Fukushima, Akimune; Itoh, Manabu; Sugiyama, Toru

    2009-03-01

    Although ultrasonic diagnostic imaging and fetal heart monitors have undergone great technological improvements, the development and use of fetal electrocardiograms to evaluate fetal arrhythmias and autonomic nervous activity have not been fully established. We verified the clinical significance of the novel signal-averaged vector-projected high amplification ECG (SAVP-ECG) method in fetuses from 48 gravidas at 32-41 weeks of gestation and in 34 neonates. SAVP-ECGs from fetuses and newborns were recorded using a modified XYZ-leads system. Once noise and maternal QRS waves were removed, the P, QRS, and T wave intervals were measured from the signal-averaged fetal ECGs. We also compared fetal and neonatal heart rates (HRs), coefficients of variation of heart rate variability (CV) as a parasympathetic nervous activity, and the ratio of low to high frequency (LF/HF ratio) as a sympathetic nervous activity. The rate of detection of a fetal ECG by SAVP-ECG was 72.9%, and the fetal and neonatal QRS and QTc intervals were not significantly different. The neonatal CVs and LF/HF ratios were significantly increased compared with those in the fetus. In conclusion, we have developed a fetal ECG recording method using the SAVP-ECG system, which we used to evaluate autonomic nervous system development.

  10. Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment

    PubMed Central

    De Cooman, Thomas; Gu, Ying; Cleeren, Evy; Claes, Kasper; Van Paesschen, Wim; Van Huffel, Sabine; Hunyadi, Borbála

    2017-01-01

    Electrocardiography has added value to automatically detect seizures in temporal lobe epilepsy (TLE) patients. The wired hospital system is not suited for a long-term seizure detection system at home. To address this need, the performance of two wearable devices, based on electrocardiography (ECG) and photoplethysmography (PPG), are compared with hospital ECG using an existing seizure detection algorithm. This algorithm classifies the seizures on the basis of heart rate features, extracted from the heart rate increase. The algorithm was applied to recordings of 11 patients in a hospital setting with 701 h capturing 47 (fronto-)temporal lobe seizures. The sensitivities of the hospital system, the wearable ECG device and the wearable PPG device were respectively 57%, 70% and 32%, with corresponding false alarms per hour of 1.92, 2.11 and 1.80. Whereas seizure detection performance using the wrist-worn PPG device was considerably lower, the performance using the wearable ECG is proven to be similar to that of the hospital ECG. PMID:29027928

  11. Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment.

    PubMed

    Vandecasteele, Kaat; De Cooman, Thomas; Gu, Ying; Cleeren, Evy; Claes, Kasper; Paesschen, Wim Van; Huffel, Sabine Van; Hunyadi, Borbála

    2017-10-13

    Electrocardiography has added value to automatically detect seizures in temporal lobe epilepsy (TLE) patients. The wired hospital system is not suited for a long-term seizure detection system at home. To address this need, the performance of two wearable devices, based on electrocardiography (ECG) and photoplethysmography (PPG), are compared with hospital ECG using an existing seizure detection algorithm. This algorithm classifies the seizures on the basis of heart rate features, extracted from the heart rate increase. The algorithm was applied to recordings of 11 patients in a hospital setting with 701 h capturing 47 (fronto-)temporal lobe seizures. The sensitivities of the hospital system, the wearable ECG device and the wearable PPG device were respectively 57%, 70% and 32%, with corresponding false alarms per hour of 1.92, 2.11 and 1.80. Whereas seizure detection performance using the wrist-worn PPG device was considerably lower, the performance using the wearable ECG is proven to be similar to that of the hospital ECG.

  12. A Pilot Study Assessing ECG versus ECHO Ventriculoventricular Optimization in Pediatric Resynchronization Patients.

    PubMed

    Punn, Rajesh; Hanisch, Debra; Motonaga, Kara S; Rosenthal, David N; Ceresnak, Scott R; Dubin, Anne M

    2016-02-01

    Cardiac resynchronization therapy indications and management are well described in adults. Echocardiography (ECHO) has been used to optimize mechanical synchrony in these patients; however, there are issues with reproducibility and time intensity. Pediatric patients add challenges, with diverse substrates and limited capacity for cooperation. Electrocardiographic (ECG) methods to assess electrical synchrony are expeditious but have not been extensively studied in children. We sought to compare ECHO and ECG CRT optimization in children. Prospective, pediatric, single-center cross-over trial comparing ECHO and ECG optimization with CRT. Patients were assigned to undergo either ECHO or ECG optimization, followed for 6 months, and crossed-over to the other assignment for another 6 months. ECHO pulsed-wave tissue Doppler and 12-lead ECG were obtained for 5 VV delays. ECG optimization was defined as the shortest QRSD and ECHO optimization as the lowest dyssynchrony index. ECHOs/ECGs were interpreted by readers blinded to optimization technique. After each 6 month period, these data were collected: ejection fraction, velocimetry-derived cardiac index, quality of life, ECHO-derived stroke distance, M-mode dyssynchrony, study cost, and time. Outcomes for each optimization method were compared. From June 2012 to December 2013, 19 patients enrolled. Mean age was 9.1 ± 4.3 years; 14 (74%) had structural heart disease. The mean time for optimization was shorter using ECG than ECHO (9 ± 1 min vs. 68 ± 13 min, P < 0.01). Mean cost for charges was $4,400 ± 700 less for ECG. No other outcome differed between groups. ECHO optimization of synchrony was not superior to ECG optimization in this pilot study. ECG optimization required less time and cost than ECHO optimization. © 2015 Wiley Periodicals, Inc.

  13. QRS Detection Algorithm for Telehealth Electrocardiogram Recordings.

    PubMed

    Khamis, Heba; Weiss, Robert; Xie, Yang; Chang, Chan-Wei; Lovell, Nigel H; Redmond, Stephen J

    2016-07-01

    QRS detection algorithms are needed to analyze electrocardiogram (ECG) recordings generated in telehealth environments. However, the numerous published QRS detectors focus on clean clinical data. Here, a "UNSW" QRS detection algorithm is described that is suitable for clinical ECG and also poorer quality telehealth ECG. The UNSW algorithm generates a feature signal containing information about ECG amplitude and derivative, which is filtered according to its frequency content and an adaptive threshold is applied. The algorithm was tested on clinical and telehealth ECG and the QRS detection performance is compared to the Pan-Tompkins (PT) and Gutiérrez-Rivas (GR) algorithm. For the MIT-BIH Arrhythmia database (virtually artifact free, clinical ECG), the overall sensitivity (Se) and positive predictivity (+P) of the UNSW algorithm was >99%, which was comparable to PT and GR. When applied to the MIT-BIH noise stress test database (clinical ECG with added calibrated noise) after artifact masking, all three algorithms had overall Se >99%, and the UNSW algorithm had higher +P (98%, p < 0.05) than PT and GR. For 250 telehealth ECG records (unsupervised recordings; dry metal electrodes), the UNSW algorithm had 98% Se and 95% +P which was superior to PT (+P: p < 0.001) and GR (Se and +P: p < 0.001). This is the first study to describe a QRS detection algorithm for telehealth data and evaluate it on clinical and telehealth ECG with superior results to published algorithms. The UNSW algorithm could be used to manage increasing telehealth ECG analysis workloads.

  14. Development of a portable wireless system for bipolar concentric ECG recording

    NASA Astrophysics Data System (ADS)

    Prats-Boluda, G.; Ye-Lin, Y.; Bueno Barrachina, J. M.; Senent, E.; Rodriguez de Sanabria, R.; Garcia-Casado, J.

    2015-07-01

    Cardiovascular diseases (CVDs) remain the biggest cause of deaths worldwide. ECG monitoring is a key tool for early diagnosis of CVDs. Conventional monitors use monopolar electrodes resulting in poor spatial resolution surface recordings and requiring extensive wiring. High-spatial resolution surface electrocardiographic recordings provide valuable information for the diagnosis of a wide range of cardiac abnormalities, including infarction and arrhythmia. The aim of this work was to develop and test a wireless recording system for acquiring high spatial resolution ECG signals, based on a flexible tripolar concentric electrode (TCE) without cable wiring or external reference electrode which would make more comnfortable its use in clinical practice. For this, a portable, wireless sensor node for analogue conditioning, digitalization and transmission of a bipolar concentric ECG signal (BC-ECG) using a TCE and a Mason-likar Lead-I ECG (ML-Lead-I ECG) signal was developed. Experimental results from a total of 32 healthy volunteers showed that the ECG fiducial points in the BC-ECG signals, recorded with external and internal reference electrode, are consistent with those of simultaneous ML-Lead-I ECG. No statistically significant difference was found in either signal amplitude or morphology, regardless of the reference electrode used, being the signal-to-noise similar to that of ML-Lead-I ECG. Furthermore, it has been observed that BC-ECG signals contain information that could not available in conventional records, specially related to atria activity. The proposed wireless sensor node provides non-invasive high-local resolution ECG signals using only a TCE without additional wiring, which would have great potential in medical diagnosis of diseases such as atrial or ventricular fibrillations or arrhythmias that currently require invasive diagnostic procedures (catheterization).

  15. A method of ECG template extraction for biometrics applications.

    PubMed

    Zhou, Xiang; Lu, Yang; Chen, Meng; Bao, Shu-Di; Miao, Fen

    2014-01-01

    ECG has attracted widespread attention as one of the most important non-invasive physiological signals in healthcare-system related biometrics for its characteristics like ease-of-monitoring, individual uniqueness as well as important clinical value. This study proposes a method of dynamic threshold setting to extract the most stable ECG waveform as the template for the consequent ECG identification process. With the proposed method, the accuracy of ECG biometrics using the dynamic time wraping for difference measures has been significantly improved. Analysis results with the self-built electrocardiogram database show that the deployment of the proposed method was able to reduce the half total error rate of the ECG biometric system from 3.35% to 1.45%. Its average running time on the platform of android mobile terminal was around 0.06 seconds, and thus demonstrates acceptable real-time performance.

  16. A new mobile phone-based ECG monitoring system.

    PubMed

    Iwamoto, Junichi; Yonezawa, Yoshiharu; Ogawa, Hiromichi Maki Hidekuni; Ninomiya, Ishio; Sada, Kouji; Hamada, Shingo; Hahn, Allen W; Caldwell, W Morton

    2007-01-01

    We have developed a system for monitoring a patient's electrocardiogram (ECG) and movement during daily activities. The complete system is mounted on chest electrodes and continuously samples the ECG and three axis accelerations. When the patient feels a heart discomfort, he or she pushes the data transmission switch on the recording system and the system sends the recorded ECG waveforms and three axis accelerations of the two prior minutes, and for two minutes after the switch is pressed. The data goes directly to a hospital server computer via a 2.4 GHz low power mobile phone. These data are stored on a server computer and downloaded to the physician's Java mobile phone. The physician can display the data on the phone's liquid crystal display.

  17. Electrocardiographic Characteristics of Potential Organ Donors and Associations with Cardiac Allograft Utilization

    PubMed Central

    Khush, Kiran K.; Menza, Rebecca; Nguyen, John; Goldstein, Benjamin A.; Zaroff, Jonathan G.; Drew, Barbara J.

    2012-01-01

    Background Current regulations require that all cardiac allograft offers for transplantation must include an interpreted 12-lead electrocardiogram (ECG). However, little is known about the expected ECG findings in potential organ donors, or the clinical significance of any identified abnormalities in terms of cardiac allograft function and suitability for transplantation. Methods and Results A single experienced reviewer interpreted the first ECG obtained after brainstem herniation in 980 potential organ donors managed by the California Transplant Donor Network from 2002-2007. ECG abnormalities were summarized, and associations between specific ECG findings and cardiac allograft utilization for transplantation were studied. ECG abnormalities were present in 51% of all cases reviewed. The most common abnormalities included voltage criteria for left ventricular hypertrophy (LVH), prolongation of the corrected QT interval (QTc), and repolarization changes (ST/T wave abnormalities). Fifty seven percent of potential cardiac allografts in this cohort were accepted for transplantation. LVH on ECG was a strong predictor of allograft non-utilization. No significant associations were seen between QTc prolongation, repolarization changes and allograft utilization for transplantation, after adjusting for donor clinical variables and echocardiographic findings. Conclusions We have performed the first comprehensive study of ECG findings in potential donors for cardiac transplantation. Many of the common ECG abnormalities seen in organ donors may result from the heightened state of sympathetic activation that occurs after brainstem herniation, and are not associated with allograft utilization for transplantation. PMID:22615333

  18. A Real-Time Cardiac Arrhythmia Classification System with Wearable Sensor Networks

    PubMed Central

    Hu, Sheng; Wei, Hongxing; Chen, Youdong; Tan, Jindong

    2012-01-01

    Long term continuous monitoring of electrocardiogram (ECG) in a free living environment provides valuable information for prevention on the heart attack and other high risk diseases. This paper presents the design of a real-time wearable ECG monitoring system with associated cardiac arrhythmia classification algorithms. One of the striking advantages is that ECG analog front-end and on-node digital processing are designed to remove most of the noise and bias. In addition, the wearable sensor node is able to monitor the patient's ECG and motion signal in an unobstructive way. To realize the real-time medical analysis, the ECG is digitalized and transmitted to a smart phone via Bluetooth. On the smart phone, the ECG waveform is visualized and a novel layered hidden Markov model is seamlessly integrated to classify multiple cardiac arrhythmias in real time. Experimental results demonstrate that the clean and reliable ECG waveform can be captured in multiple stressed conditions and the real-time classification on cardiac arrhythmia is competent to other workbenches. PMID:23112746

  19. A configurable and low-power mixed signal SoC for portable ECG monitoring applications.

    PubMed

    Kim, Hyejung; Kim, Sunyoung; Van Helleputte, Nick; Artes, Antonio; Konijnenburg, Mario; Huisken, Jos; Van Hoof, Chris; Yazicioglu, Refet Firat

    2014-04-01

    This paper describes a mixed-signal ECG System-on-Chip (SoC) that is capable of implementing configurable functionality with low-power consumption for portable ECG monitoring applications. A low-voltage and high performance analog front-end extracts 3-channel ECG signals and single channel electrode-tissue-impedance (ETI) measurement with high signal quality. This can be used to evaluate the quality of the ECG measurement and to filter motion artifacts. A custom digital signal processor consisting of 4-way SIMD processor provides the configurability and advanced functionality like motion artifact removal and R peak detection. A built-in 12-bit analog-to-digital converter (ADC) is capable of adaptive sampling achieving a compression ratio of up to 7, and loop buffer integration reduces the power consumption for on-chip memory access. The SoC is implemented in 0.18 μm CMOS process and consumes 32 μ W from a 1.2 V while heart beat detection application is running, and integrated in a wireless ECG monitoring system with Bluetooth protocol. Thanks to the ECG SoC, the overall system power consumption can be reduced significantly.

  20. Quantitative Assessment of Arrhythmia Using Non-linear Approach: A Non-invasive Prognostic Tool

    NASA Astrophysics Data System (ADS)

    Chakraborty, Monisha; Ghosh, Dipak

    2017-12-01

    Accurate prognostic tool to identify severity of Arrhythmia is yet to be investigated, owing to the complexity of the ECG signal. In this paper, we have shown that quantitative assessment of Arrhythmia is possible using non-linear technique based on "Hurst Rescaled Range Analysis". Although the concept of applying "non-linearity" for studying various cardiac dysfunctions is not entirely new, the novel objective of this paper is to identify the severity of the disease, monitoring of different medicine and their dose, and also to assess the efficiency of different medicine. The approach presented in this work is simple which in turn will help doctors in efficient disease management. In this work, Arrhythmia ECG time series are collected from MIT-BIH database. Normal ECG time series are acquired using POLYPARA system. Both time series are analyzed in thelight of non-linear approach following the method "Rescaled Range Analysis". The quantitative parameter, "Fractal Dimension" (D) is obtained from both types of time series. The major finding is that Arrhythmia ECG poses lower values of D as compared to normal. Further, this information can be used to access the severity of Arrhythmia quantitatively, which is a new direction of prognosis as well as adequate software may be developed for the use of medical practice.

  1. Quantitative Assessment of Arrhythmia Using Non-linear Approach: A Non-invasive Prognostic Tool

    NASA Astrophysics Data System (ADS)

    Chakraborty, Monisha; Ghosh, Dipak

    2018-04-01

    Accurate prognostic tool to identify severity of Arrhythmia is yet to be investigated, owing to the complexity of the ECG signal. In this paper, we have shown that quantitative assessment of Arrhythmia is possible using non-linear technique based on "Hurst Rescaled Range Analysis". Although the concept of applying "non-linearity" for studying various cardiac dysfunctions is not entirely new, the novel objective of this paper is to identify the severity of the disease, monitoring of different medicine and their dose, and also to assess the efficiency of different medicine. The approach presented in this work is simple which in turn will help doctors in efficient disease management. In this work, Arrhythmia ECG time series are collected from MIT-BIH database. Normal ECG time series are acquired using POLYPARA system. Both time series are analyzed in thelight of non-linear approach following the method "Rescaled Range Analysis". The quantitative parameter, "Fractal Dimension" (D) is obtained from both types of time series. The major finding is that Arrhythmia ECG poses lower values of D as compared to normal. Further, this information can be used to access the severity of Arrhythmia quantitatively, which is a new direction of prognosis as well as adequate software may be developed for the use of medical practice.

  2. Extraction of fetal ECG signal by an improved method using extended Kalman smoother framework from single channel abdominal ECG signal.

    PubMed

    Panigrahy, D; Sahu, P K

    2017-03-01

    This paper proposes a five-stage based methodology to extract the fetal electrocardiogram (FECG) from the single channel abdominal ECG using differential evolution (DE) algorithm, extended Kalman smoother (EKS) and adaptive neuro fuzzy inference system (ANFIS) framework. The heart rate of the fetus can easily be detected after estimation of the fetal ECG signal. The abdominal ECG signal contains fetal ECG signal, maternal ECG component, and noise. To estimate the fetal ECG signal from the abdominal ECG signal, removal of the noise and the maternal ECG component presented in it is necessary. The pre-processing stage is used to remove the noise from the abdominal ECG signal. The EKS framework is used to estimate the maternal ECG signal from the abdominal ECG signal. The optimized parameters of the maternal ECG components are required to develop the state and measurement equation of the EKS framework. These optimized maternal ECG parameters are selected by the differential evolution algorithm. The relationship between the maternal ECG signal and the available maternal ECG component in the abdominal ECG signal is nonlinear. To estimate the actual maternal ECG component present in the abdominal ECG signal and also to recognize this nonlinear relationship the ANFIS is used. Inputs to the ANFIS framework are the output of EKS and the pre-processed abdominal ECG signal. The fetal ECG signal is computed by subtracting the output of ANFIS from the pre-processed abdominal ECG signal. Non-invasive fetal ECG database and set A of 2013 physionet/computing in cardiology challenge database (PCDB) are used for validation of the proposed methodology. The proposed methodology shows a sensitivity of 94.21%, accuracy of 90.66%, and positive predictive value of 96.05% from the non-invasive fetal ECG database. The proposed methodology also shows a sensitivity of 91.47%, accuracy of 84.89%, and positive predictive value of 92.18% from the set A of PCDB.

  3. CardioGuard: A Brassiere-Based Reliable ECG Monitoring Sensor System for Supporting Daily Smartphone Healthcare Applications

    PubMed Central

    Kwon, Sungjun; Kim, Jeehoon; Kang, Seungwoo; Lee, Youngki; Baek, Hyunjae

    2014-01-01

    Abstract We propose CardioGuard, a brassiere-based reliable electrocardiogram (ECG) monitoring sensor system, for supporting daily smartphone healthcare applications. It is designed to satisfy two key requirements for user-unobtrusive daily ECG monitoring: reliability of ECG sensing and usability of the sensor. The system is validated through extensive evaluations. The evaluation results showed that the CardioGuard sensor reliably measure the ECG during 12 representative daily activities including diverse movement levels; 89.53% of QRS peaks were detected on average. The questionnaire-based user study with 15 participants showed that the CardioGuard sensor was comfortable and unobtrusive. Additionally, the signal-to-noise ratio test and the washing durability test were conducted to show the high-quality sensing of the proposed sensor and its physical durability in practical use, respectively. PMID:25405527

  4. A three-lead, programmable, and microcontroller-based electrocardiogram generator with frequency domain characteristics of heart rate variability.

    PubMed

    Wei, Ying-Chieh; Wei, Ying-Yu; Chang, Kai-Hsiung; Young, Ming-Shing

    2012-04-01

    The objective of this study is to design and develop a programmable electrocardiogram (ECG) generator with frequency domain characteristics of heart rate variability (HRV) which can be used to test the efficiency of ECG algorithms and to calibrate and maintain ECG equipment. We simplified and modified the three coupled ordinary differential equations in McSharry's model to a single differential equation to obtain the ECG signal. This system not only allows the signal amplitude, heart rate, QRS-complex slopes, and P- and T-wave position parameters to be adjusted, but can also be used to adjust the very low frequency, low frequency, and high frequency components of HRV frequency domain characteristics. The system can be tuned to function with HRV or not. When the HRV function is on, the average heart rate can be set to a value ranging from 20 to 122 beats per minute (BPM) with an adjustable variation of 1 BPM. When the HRV function is off, the heart rate can be set to a value ranging from 20 to 139 BPM with an adjustable variation of 1 BPM. The amplitude of the ECG signal can be set from 0.0 to 330 mV at a resolution of 0.005 mV. These parameters can be adjusted either via input through a keyboard or through a graphical user interface (GUI) control panel that was developed using LABVIEW. The GUI control panel depicts a preview of the ECG signal such that the user can adjust the parameters to establish a desired ECG morphology. A complete set of parameters can be stored in the flash memory of the system via a USB 2.0 interface. Our system can generate three different types of synthetic ECG signals for testing the efficiency of an ECG algorithm or calibrating and maintaining ECG equipment. © 2012 American Institute of Physics

  5. A three-lead, programmable, and microcontroller-based electrocardiogram generator with frequency domain characteristics of heart rate variability

    NASA Astrophysics Data System (ADS)

    Wei, Ying-Chieh; Wei, Ying-Yu; Chang, Kai-Hsiung; Young, Ming-Shing

    2012-04-01

    The objective of this study is to design and develop a programmable electrocardiogram (ECG) generator with frequency domain characteristics of heart rate variability (HRV) which can be used to test the efficiency of ECG algorithms and to calibrate and maintain ECG equipment. We simplified and modified the three coupled ordinary differential equations in McSharry's model to a single differential equation to obtain the ECG signal. This system not only allows the signal amplitude, heart rate, QRS-complex slopes, and P- and T-wave position parameters to be adjusted, but can also be used to adjust the very low frequency, low frequency, and high frequency components of HRV frequency domain characteristics. The system can be tuned to function with HRV or not. When the HRV function is on, the average heart rate can be set to a value ranging from 20 to 122 beats per minute (BPM) with an adjustable variation of 1 BPM. When the HRV function is off, the heart rate can be set to a value ranging from 20 to 139 BPM with an adjustable variation of 1 BPM. The amplitude of the ECG signal can be set from 0.0 to 330 mV at a resolution of 0.005 mV. These parameters can be adjusted either via input through a keyboard or through a graphical user interface (GUI) control panel that was developed using LABVIEW. The GUI control panel depicts a preview of the ECG signal such that the user can adjust the parameters to establish a desired ECG morphology. A complete set of parameters can be stored in the flash memory of the system via a USB 2.0 interface. Our system can generate three different types of synthetic ECG signals for testing the efficiency of an ECG algorithm or calibrating and maintaining ECG equipment.

  6. A New Algorithm to Diagnose Atrial Ectopic Origin from Multi Lead ECG Systems - Insights from 3D Virtual Human Atria and Torso

    PubMed Central

    Alday, Erick A. Perez; Colman, Michael A.; Langley, Philip; Butters, Timothy D.; Higham, Jonathan; Workman, Antony J.; Hancox, Jules C.; Zhang, Henggui

    2015-01-01

    Rapid atrial arrhythmias such as atrial fibrillation (AF) predispose to ventricular arrhythmias, sudden cardiac death and stroke. Identifying the origin of atrial ectopic activity from the electrocardiogram (ECG) can help to diagnose the early onset of AF in a cost-effective manner. The complex and rapid atrial electrical activity during AF makes it difficult to obtain detailed information on atrial activation using the standard 12-lead ECG alone. Compared to conventional 12-lead ECG, more detailed ECG lead configurations may provide further information about spatio-temporal dynamics of the body surface potential (BSP) during atrial excitation. We apply a recently developed 3D human atrial model to simulate electrical activity during normal sinus rhythm and ectopic pacing. The atrial model is placed into a newly developed torso model which considers the presence of the lungs, liver and spinal cord. A boundary element method is used to compute the BSP resulting from atrial excitation. Elements of the torso mesh corresponding to the locations of the placement of the electrodes in the standard 12-lead and a more detailed 64-lead ECG configuration were selected. The ectopic focal activity was simulated at various origins across all the different regions of the atria. Simulated BSP maps during normal atrial excitation (i.e. sinoatrial node excitation) were compared to those observed experimentally (obtained from the 64-lead ECG system), showing a strong agreement between the evolution in time of the simulated and experimental data in the P-wave morphology of the ECG and dipole evolution. An algorithm to obtain the location of the stimulus from a 64-lead ECG system was developed. The algorithm presented had a success rate of 93%, meaning that it correctly identified the origin of atrial focus in 75/80 simulations, and involved a general approach relevant to any multi-lead ECG system. This represents a significant improvement over previously developed algorithms. PMID:25611350

  7. Assurance of energy efficiency and data security for ECG transmission in BASNs.

    PubMed

    Ma, Tao; Shrestha, Pradhumna Lal; Hempel, Michael; Peng, Dongming; Sharif, Hamid; Chen, Hsiao-Hwa

    2012-04-01

    With the technological advancement in body area sensor networks (BASNs), low cost high quality electrocardiographic (ECG) diagnosis systems have become important equipment for healthcare service providers. However, energy consumption and data security with ECG systems in BASNs are still two major challenges to tackle. In this study, we investigate the properties of compressed ECG data for energy saving as an effort to devise a selective encryption mechanism and a two-rate unequal error protection (UEP) scheme. The proposed selective encryption mechanism provides a simple and yet effective security solution for an ECG sensor-based communication platform, where only one percent of data is encrypted without compromising ECG data security. This part of the encrypted data is essential to ECG data quality due to its unequally important contribution to distortion reduction. The two-rate UEP scheme achieves a significant additional energy saving due to its unequal investment of communication energy to the outcomes of the selective encryption, and thus, it maintains a high ECG data transmission quality. Our results show the improvements in communication energy saving of about 40%, and demonstrate a higher transmission quality and security measured in terms of wavelet-based weighted percent root-mean-squared difference.

  8. Study design and rationale for biomedical shirt-based electrocardiography monitoring in relevant clinical situations: ECG-shirt study.

    PubMed

    Balsam, Paweł; Lodziński, Piotr; Tymińska, Agata; Ozierański, Krzysztof; Januszkiewicz, Łukasz; Główczyńska, Renata; Wesołowska, Katarzyna; Peller, Michał; Pietrzak, Radosław; Książczyk, Tomasz; Borodzicz, Sonia; Kołtowski, Łukasz; Borkowski, Mariusz; Werner, Bożena; Opolski, Grzegorz; Grabowski, Marcin

    2018-01-01

    Today, the main challenge for researchers is to develop new technologies which may help to improve the diagnoses of cardiovascular disease (CVD), thereby reducing healthcare costs and improving the quality of life for patients. This study aims to show the utility of biomedical shirt-based electrocardiography (ECG) monitoring of patients with CVD in different clinical situations using the Nuubo® ECG (nECG) system. An investigator-initiated, multicenter, prospective observational study was carried out in a cardiology (adult and pediatric) and cardiac rehabilitation wards. ECG monitoring was used with the biomedical shirt in the following four independent groups of patients: 1) 30 patients after pulmonary vein isolation (PVI), 2) 30 cardiac resynchronization therapy (CRT) recipients, 3) 120 patients during cardiac rehabilitation after myocardial infarction, and 4) 40 pediatric patients with supraventricular tachycardia (SVT) before electrophysiology study. Approval for all study groups was obtained from the institutional review board. The biomedical shirt captures the electrocardiographic signal via textile electrodes integrated into a garment. The software allows the visualization and analysis of data such as ECG, heart rate, arrhythmia detecting algorithm and relative position of the body is captured by an electronic device. The major advantages of the nECG system are continuous ECG monitoring during daily activities, high quality of ECG recordings, as well as assurance of a proper adherence due to adequate comfort while wearing the shirt. There are only a few studies that have examined wearable systems, especially in pediatric populations. This study is registered in ClinicalTrials.gov: Identifier NCT03068169. (Cardiol J 2018; 25, 1: 52-59).

  9. [Monitor of ECG signal and heart rate using a mobile phone with Bluetooth communication protocol].

    PubMed

    Becerra-Luna, Brayans; Dávila-García, Rodrigo; Salgado-Rodríguez, Paola; Martínez-Memije, Raúl; Infante-Vázquez, Oscar

    2012-01-01

    To develop a portable signal monitoring equipment for electrocardiography (ECG) and heart rate (HR), communicated with a mobile phone using the Bluetooth (BT) communication protocol for display of the signal on screen. A monitoring system was designed in which the electronic section performs the ECG signal acquisition, as well as amplification, filtering, analog to digital conversion and transmission of the ECG and HR using BT. Two programs were developed for the system. The first one calculates HR through QRS identification and sends the ECG signals and HR to the mobile, and the second program is an application to acquire and display them on the mobile screen. We developed a portable electronic system powered by a 9 volt battery, with amplification and bandwidth meeting the international standards for ECG monitoring. The QRS complex identification was performed using the second derivative algorithm, while the programs allow sending and receiving information from the ECG and HR via BT, and viewing it on the mobile screen. The monitoring is feasible within distances of 15 m and it has been tested in various mobiles telephones of brands Nokia®, Sony Ericsson® and Samsung®. This system shows an alternative for mobile monitoring using BT and Java 2 Micro Edition (J2ME) programming. It allows the register of the ECG trace and HR, and it can be implemented in different phones. Copyright © 2011 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  10. FPGA Implementation of Heart Rate Monitoring System.

    PubMed

    Panigrahy, D; Rakshit, M; Sahu, P K

    2016-03-01

    This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.

  11. Remote health monitoring system for detecting cardiac disorders.

    PubMed

    Bansal, Ayush; Kumar, Sunil; Bajpai, Anurag; Tiwari, Vijay N; Nayak, Mithun; Venkatesan, Shankar; Narayanan, Rangavittal

    2015-12-01

    Remote health monitoring system with clinical decision support system as a key component could potentially quicken the response of medical specialists to critical health emergencies experienced by their patients. A monitoring system, specifically designed for cardiac care with electrocardiogram (ECG) signal analysis as the core diagnostic technique, could play a vital role in early detection of a wide range of cardiac ailments, from a simple arrhythmia to life threatening conditions such as myocardial infarction. The system that the authors have developed consists of three major components, namely, (a) mobile gateway, deployed on patient's mobile device, that receives 12-lead ECG signals from any ECG sensor, (b) remote server component that hosts algorithms for accurate annotation and analysis of the ECG signal and (c) point of care device of the doctor to receive a diagnostic report from the server based on the analysis of ECG signals. In the present study, their focus has been toward developing a system capable of detecting critical cardiac events well in advance using an advanced remote monitoring system. A system of this kind is expected to have applications ranging from tracking wellness/fitness to detection of symptoms leading to fatal cardiac events.

  12. Management of hyperkalaemia.

    PubMed

    Maxwell, A P; Linden, K; O'Donnell, S; Hamilton, P K; McVeigh, G E

    2013-01-01

    Hyperkalaemia, an elevated extracellular fluid potassium concentration, is a common electrolyte disorder and is present in 1-10% of hospitalised patients. Elevated serum potassium concentrations are usually asymptomatic but may be associated with electrocardiogram (ECG) changes. Hyperkalaemia occasionally leads to life-threatening cardiac arrhythmias. Prompt recognition of this disorder, patient risk management and administration of appropriate treatment can prevent serious cardiac complications of hyperkalaemia. Further assessment of the underlying basis for hyperkalaemia usually reveals a problem with renal potassium excretion (rather than transcellular shift of potassium or excess potassium intake). Reduced potassium excretion is typically associated with decreased potassium secretion in the aldosterone-sensitive distal nephron of the kidney. Common causes for hyperkalaemia include kidney failure, limited delivery of sodium and water to the distal nephron and drugs that inhibit the renin-angiotensin-aldosterone system. Treatment of life-threatening hyperkalaemia (particularly those patients with ECG changes) involves administration of intravenous calcium salts to stabilise the resting cardiac membrane potential. The potassium concentration can be lowered by administration of intravenous insulin combined with an infusion of glucose to stimulate intracellular uptake of potassium. Nebulised β-2 adrenoceptor agonists can augment the effects of intravenous insulin and glucose pending more definitive management of the recurrent hyperkalaemia risk. Additional management steps include stopping further potassium intake and careful review of prescribed drugs that may be adversely affecting potassium homeostasis. Changes to prescribing systems and an agreed institutional protocol for management of hyperkalaemia can improve patient safety for this frequently encountered electrolyte disorder.

  13. Field programmable gate array based fuzzy neural signal processing system for differential diagnosis of QRS complex tachycardia and tachyarrhythmia in noisy ECG signals.

    PubMed

    Chowdhury, Shubhajit Roy

    2012-04-01

    The paper reports of a Field Programmable Gate Array (FPGA) based embedded system for detection of QRS complex in a noisy electrocardiogram (ECG) signal and thereafter differential diagnosis of tachycardia and tachyarrhythmia. The QRS complex has been detected after application of entropy measure of fuzziness to build a detection function of ECG signal, which has been previously filtered to remove power line interference and base line wander. Using the detected QRS complexes, differential diagnosis of tachycardia and tachyarrhythmia has been performed. The entire algorithm has been realized in hardware on an FPGA. Using the standard CSE ECG database, the algorithm performed highly effectively. The performance of the algorithm in respect of QRS detection with sensitivity (Se) of 99.74% and accuracy of 99.5% is achieved when tested using single channel ECG with entropy criteria. The performance of the QRS detection system has been compared and found to be better than most of the QRS detection systems available in literature. Using the system, 200 patients have been diagnosed with an accuracy of 98.5%.

  14. Automated diagnosis of congestive heart failure using dual tree complex wavelet transform and statistical features extracted from 2s of ECG signals.

    PubMed

    Sudarshan, Vidya K; Acharya, U Rajendra; Oh, Shu Lih; Adam, Muhammad; Tan, Jen Hong; Chua, Chua Kuang; Chua, Kok Poo; Tan, Ru San

    2017-04-01

    Identification of alarming features in the electrocardiogram (ECG) signal is extremely significant for the prediction of congestive heart failure (CHF). ECG signal analysis carried out using computer-aided techniques can speed up the diagnosis process and aid in the proper management of CHF patients. Therefore, in this work, dual tree complex wavelets transform (DTCWT)-based methodology is proposed for an automated identification of ECG signals exhibiting CHF from normal. In the experiment, we have performed a DTCWT on ECG segments of 2s duration up to six levels to obtain the coefficients. From these DTCWT coefficients, statistical features are extracted and ranked using Bhattacharyya, entropy, minimum redundancy maximum relevance (mRMR), receiver-operating characteristics (ROC), Wilcoxon, t-test and reliefF methods. Ranked features are subjected to k-nearest neighbor (KNN) and decision tree (DT) classifiers for automated differentiation of CHF and normal ECG signals. We have achieved 99.86% accuracy, 99.78% sensitivity and 99.94% specificity in the identification of CHF affected ECG signals using 45 features. The proposed method is able to detect CHF patients accurately using only 2s of ECG signal length and hence providing sufficient time for the clinicians to further investigate on the severity of CHF and treatments. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Weekly Checks Improve Real-Time Prehospital ECG Transmission in Suspected STEMI.

    PubMed

    D'Arcy, Nicole T; Bosson, Nichole; Kaji, Amy H; Bui, Quang T; French, William J; Thomas, Joseph L; Elizarraraz, Yvonne; Gonzalez, Natalia; Garcia, Jose; Niemann, James T

    2018-06-01

    IntroductionField identification of ST-elevation myocardial infarction (STEMI) and advanced hospital notification decreases first-medical-contact-to-balloon (FMC2B) time. A recent study in this system found that electrocardiogram (ECG) transmission following a STEMI alert was frequently unsuccessful.HypothesisInstituting weekly test ECG transmissions from paramedic units to the hospital would increase successful transmission of ECGs and decrease FMC2B and door-to-balloon (D2B) times. This was a natural experiment of consecutive patients with field-identified STEMI transported to a single percutaneous coronary intervention (PCI)-capable hospital in a regional STEMI system before and after implementation of scheduled test ECG transmissions. In November 2014, paramedic units began weekly test transmissions. The mobile intensive care nurse (MICN) confirmed the transmission, or if not received, contacted the paramedic unit and the department's nurse educator to identify and resolve the problem. Per system-wide protocol, paramedics transmit all ECGs with interpretation of STEMI. Receiving hospitals submit patient data to a single registry as part of ongoing system quality improvement. The frequency of successful ECG transmission and time to intervention (FMC2B and D2B times) in the 18 months following implementation was compared to the 10 months prior. Post-implementation, the time the ECG transmission was received was also collected to determine the transmission gap time (time from ECG acquisition to ECG transmission received) and the advanced notification time (time from ECG transmission received to patient arrival). There were 388 patients with field ECG interpretations of STEMI, 131 pre-intervention and 257 post-intervention. The frequency of successful transmission post-intervention was 73% compared to 64% prior; risk difference (RD)=9%; 95% CI, 1-18%. In the post-intervention period, the median FMC2B time was 79 minutes (inter-quartile range [IQR]=68-102) versus 86 minutes (IQR=71-108) pre-intervention (P=.3) and the median D2B time was 59 minutes (IQR=44-74) versus 60 minutes (IQR=53-88) pre-intervention (P=.2). The median transmission gap was three minutes (IQR=1-8) and median advanced notification time was 16 minutes (IQR=10-25). Implementation of weekly test ECG transmissions was associated with improvement in successful real-time transmissions from field to hospital, which provided a median advanced notification time of 16 minutes, but no decrease in FMC2B or D2B times. D'ArcyNT, BossonN, KajiAH, BuiQT, FrenchWJ, ThomasJL, ElizarrarazY, GonzalezN, GarciaJ, NiemannJT. Weekly checks improve real-time prehospital ECG transmission in suspected STEMI. Prehosp Disaster Med. 2018;33(3):245-249.

  16. Identifying UMLS concepts from ECG Impressions using KnowledgeMap

    PubMed Central

    Denny, Joshua C.; Spickard, Anderson; Miller, Randolph A; Schildcrout, Jonathan; Darbar, Dawood; Rosenbloom, S. Trent; Peterson, Josh F.

    2005-01-01

    Electrocardiogram (ECG) impressions represent a wealth of medical information for potential decision support and drug-effect discovery. Much of this information is inaccessible to automated methods in the free-text portion of the ECG report. We studied the application of the KnowledgeMap concept identifier (KMCI) to map Unified Medical Language System (UMLS) concepts from ECG impressions. ECGs were processed by KMCI and the results scored for accuracy by multiple raters. Reviewers also recorded unidentified concepts through the scoring interface. Overall, KMCI correctly identified 1059 out of 1171 concepts for a recall of 0.90. Precision, indicating the proportion of ECG concepts correctly identified, was 0.94. KMCI was particularly effective at identifying ECG rhythms (330/333), perfusion changes (65/66), and noncardiac medical concepts (11/11). In conclusion, KMCI is an effective method for mapping ECG impressions to UMLS concepts. PMID:16779029

  17. An optimized compression algorithm for real-time ECG data transmission in wireless network of medical information systems.

    PubMed

    Cho, Gyoun-Yon; Lee, Seo-Joon; Lee, Tae-Ro

    2015-01-01

    Recent medical information systems are striving towards real-time monitoring models to care patients anytime and anywhere through ECG signals. However, there are several limitations such as data distortion and limited bandwidth in wireless communications. In order to overcome such limitations, this research focuses on compression. Few researches have been made to develop a specialized compression algorithm for ECG data transmission in real-time monitoring wireless network. Not only that, recent researches' algorithm is not appropriate for ECG signals. Therefore this paper presents a more developed algorithm EDLZW for efficient ECG data transmission. Results actually showed that the EDLZW compression ratio was 8.66, which was a performance that was 4 times better than any other recent compression method widely used today.

  18. One-Dimensional Signal Extraction Of Paper-Written ECG Image And Its Archiving

    NASA Astrophysics Data System (ADS)

    Zhang, Zhi-ni; Zhang, Hong; Zhuang, Tian-ge

    1987-10-01

    A method for converting paper-written electrocardiograms to one dimensional (1-D) signals for archival storage on floppy disk is presented here. Appropriate image processing techniques were employed to remove the back-ground noise inherent to ECG recorder charts and to reconstruct the ECG waveform. The entire process consists of (1) digitization of paper-written ECGs with an image processing system via a TV camera; (2) image preprocessing, including histogram filtering and binary image generation; (3) ECG feature extraction and ECG wave tracing, and (4) transmission of the processed ECG data to IBM-PC compatible floppy disks for storage and retrieval. The algorithms employed here may also be used in the recognition of paper-written EEG or EMG and may be useful in robotic vision.

  19. Threshold-based system for noise detection in multilead ECG recordings.

    PubMed

    Jekova, Irena; Krasteva, Vessela; Christov, Ivaylo; Abächerli, Roger

    2012-09-01

    This paper presents a system for detection of the most common noise types seen on the electrocardiogram (ECG) in order to evaluate whether an episode from 12-lead ECG is reliable for diagnosis. It implements criteria for estimation of the noise corruption level in specific frequency bands, aiming to identify the main sources of ECG quality disruption, such as missing signal or limited dynamics of the QRS components above 4 Hz; presence of high amplitude and steep artifacts seen above 1 Hz; baseline drift estimated at frequencies below 1 Hz; power-line interference in a band ±2 Hz around its central frequency; high-frequency and electromyographic noises above 20 Hz. All noise tests are designed to process the ECG series in the time domain, including 13 adjustable thresholds for amplitude and slope criteria which are evaluated in adjustable time intervals, as well as number of leads. The system allows flexible extension toward application-specific requirements for the noise levels in acceptable quality ECGs. Training of different thresholds' settings to determine different positive noise detection rates is performed with the annotated set of 1000 ECGs from the PhysioNet database created for the Computing in Cardiology Challenge 2011. Two implementations are highlighted on the receiver operating characteristic (area 0.968) to fit to different applications. The implementation with high sensitivity (Se = 98.7%, Sp = 80.9%) appears as a reliable alarm when there are any incidental problems with the ECG acquisition, while the implementation with high specificity (Sp = 97.8%, Se = 81.8%) is less susceptible to transient problems but rather validates noisy ECGs with acceptable quality during a small portion of the recording.

  20. Wavelet-based Encoding Scheme for Controlling Size of Compressed ECG Segments in Telecardiology Systems.

    PubMed

    Al-Busaidi, Asiya M; Khriji, Lazhar; Touati, Farid; Rasid, Mohd Fadlee; Mnaouer, Adel Ben

    2017-09-12

    One of the major issues in time-critical medical applications using wireless technology is the size of the payload packet, which is generally designed to be very small to improve the transmission process. Using small packets to transmit continuous ECG data is still costly. Thus, data compression is commonly used to reduce the huge amount of ECG data transmitted through telecardiology devices. In this paper, a new ECG compression scheme is introduced to ensure that the compressed ECG segments fit into the available limited payload packets, while maintaining a fixed CR to preserve the diagnostic information. The scheme automatically divides the ECG block into segments, while maintaining other compression parameters fixed. This scheme adopts discrete wavelet transform (DWT) method to decompose the ECG data, bit-field preserving (BFP) method to preserve the quality of the DWT coefficients, and a modified running-length encoding (RLE) scheme to encode the coefficients. The proposed dynamic compression scheme showed promising results with a percentage packet reduction (PR) of about 85.39% at low percentage root-mean square difference (PRD) values, less than 1%. ECG records from MIT-BIH Arrhythmia Database were used to test the proposed method. The simulation results showed promising performance that satisfies the needs of portable telecardiology systems, like the limited payload size and low power consumption.

  1. Screening entire healthcare system ECG database: Association of deep terminal negativity of P wave in lead V1 and ECG referral with mortality.

    PubMed

    Junell, Allison; Thomas, Jason; Hawkins, Lauren; Sklenar, Jiri; Feldman, Trevor; Henrikson, Charles A; Tereshchenko, Larisa G

    2017-02-01

    Each encounter of asymptomatic individuals with the healthcare system presents an opportunity for improvement of cardiovascular disease (CVD) awareness and sudden cardiac death (SCD) risk assessment. ECG sign deep terminal negativity of the P wave in V1 (DTNP V1 ) was shown to be associated with an increased risk of SCD in the general population. To evaluate association of DTNP V1 with all-cause mortality and newly diagnosed atrial fibrillation (AFib) in the large tertiary healthcare system patient population. Retrospective double cohort study compared two levels of exposure (automatically measured amplitude of P-prime (Pp) in V1): DTNP V1 (Pp from -100μV to -200μV) and ZeroPpV1 (Pp=0). An entire healthcare system (2010-2014) ECG database was screened. Medical records of children and patients with previously diagnosed AFib/atrial flutter (AFl), implanted pacemaker or cardioverter-defibrillator were excluded. DTNP V1 (n=3,413) and ZeroPpV1 (n=3,405) cohorts were matched by age and sex. Primary outcome was all-cause mortality. Secondary outcomes were newly diagnosed AFib/AFl. Median follow-up was 2.5 y. DTNP V1 was associated with all-cause mortality (HR 1.95(1.64-2.31); P<0.0001) and newly diagnosed AFib (HR 1.29(1.04-1.59); P=0.021) after adjustment for CVD, comorbidities, other ECG parameters, medications, and index ECG referral. Index ECG referral by a cardiologist was independently associated with 34% relative risk reduction of mortality (HR 0.66(0.52-0.84); P=0.001), as compared to ECG referral by a non-cardiologist. DTNP V1 is independently associated with twice higher risk of all-cause death, as compared to patients without P prime in V1. Life-saving effect of the index ECG referral by a cardiologist requires further study. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Detection of heart rate and rhythm with a smartphone-based electrocardiograph versus a reference standard electrocardiograph in dogs and cats.

    PubMed

    Kraus, Marc S; Gelzer, Anna R; Rishniw, Mark

    2016-07-15

    OBJECTIVE To evaluate the diagnostic utility of ECGs acquired with a smartphone-based device, compared with reference 6-lead ECGs, for identification of heart rate and rhythm in dogs and cats. DESIGN Prospective study. ANIMALS 51 client-owned dogs and 27 client-owned cats. PROCEDURES Patients examined by a small animal referral cardiology service between April 2012 and January 2013 were enrolled consecutively. In each patient, a 30-second ECG was simultaneously acquired with a smartphone-based device (a bipolar, single-lead recorder coupled to a smartphone with an ECG application) and a standard 6-lead ECG machine. Recordings were evaluated by 3 board-certified cardiologists, and intra- and interobserver agreement were evaluated for both rhythm diagnosis and QRS polarity identification. RESULTS Values for instantaneous and mean heart rates for the smartphone-acquired and reference ECGs were within 1 beat of each other when mean heart rates were calculated. Intraobserver agreement for rhythm assessment was very high, with maximum disagreement for any observer for only 2 of 51 dogs and only 4 of 27 cats. There was minimal disagreement in the polarity of depolarization between the smartphone-acquired and reference ECGs in dogs but frequent disagreement in cats. Interobserver agreement for smartphone-acquired ECGs was similar to that for reference ECGs. with all 3 observers agreeing on the rhythm analysis and minimal disagreement on polarity. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that ECGs acquired with the smartphone-based device accurately identified heart rate and rhythm in dogs and cats. Thus, the device may allow veterinarians to evaluate and manage cardiac arrhythmias relatively inexpensively at the cage side and could also allow clinicians to rapidly share information via email for further consultation, potentially enhancing patient care.

  3. Design and Development of Intelligent Electrodes for Future Digital Health Monitoring: A Review

    NASA Astrophysics Data System (ADS)

    Khairuddin, A. M.; Azir, K. N. F. Ku; Kan, P. Eh

    2018-03-01

    Electrodes are sensors used in electrocardiography (ECG) monitoring system to diagnose heart diseases. Over the years, diverse types of electrodes have been designed and developed to improve ECG monitoring system. However, more recently, with the technological advances and capabilities from the Internet of Things (IoT), cloud computing and data analytics in personalized healthcare, researchers are attempting to design and develop more effective as well as flexible ECG devices by using intelligent electrodes. This paper reviews previous works on electrodes used in electrocardiography (ECG) monitoring devices to identify the key ftures for designing and developing intelligent electrodes in digital health monitoring devices.

  4. Revisiting QRS detection methodologies for portable, wearable, battery-operated, and wireless ECG systems.

    PubMed

    Elgendi, Mohamed; Eskofier, Björn; Dokos, Socrates; Abbott, Derek

    2014-01-01

    Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable point-of-care diagnostic systems can therefore help unveil and treat cardiovascular diseases. The basis for ECG analysis is a robust detection of the prominent QRS complex, as well as other ECG signal characteristics. However, it is not clear from the literature which ECG analysis algorithms are suited for an implementation on a mobile device. We investigate current QRS detection algorithms based on three assessment criteria: 1) robustness to noise, 2) parameter choice, and 3) numerical efficiency, in order to target a universal fast-robust detector. Furthermore, existing QRS detection algorithms may provide an acceptable solution only on small segments of ECG signals, within a certain amplitude range, or amid particular types of arrhythmia and/or noise. These issues are discussed in the context of a comparison with the most conventional algorithms, followed by future recommendations for developing reliable QRS detection schemes suitable for implementation on battery-operated mobile devices.

  5. Revisiting QRS Detection Methodologies for Portable, Wearable, Battery-Operated, and Wireless ECG Systems

    PubMed Central

    Elgendi, Mohamed; Eskofier, Björn; Dokos, Socrates; Abbott, Derek

    2014-01-01

    Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable point-of-care diagnostic systems can therefore help unveil and treat cardiovascular diseases. The basis for ECG analysis is a robust detection of the prominent QRS complex, as well as other ECG signal characteristics. However, it is not clear from the literature which ECG analysis algorithms are suited for an implementation on a mobile device. We investigate current QRS detection algorithms based on three assessment criteria: 1) robustness to noise, 2) parameter choice, and 3) numerical efficiency, in order to target a universal fast-robust detector. Furthermore, existing QRS detection algorithms may provide an acceptable solution only on small segments of ECG signals, within a certain amplitude range, or amid particular types of arrhythmia and/or noise. These issues are discussed in the context of a comparison with the most conventional algorithms, followed by future recommendations for developing reliable QRS detection schemes suitable for implementation on battery-operated mobile devices. PMID:24409290

  6. Saturation of the right-leg drive amplifier in low-voltage ECG monitors.

    PubMed

    Freeman, Daniel K; Gatzke, Ronald D; Mallas, Georgios; Chen, Yu; Brouse, Chris J

    2015-01-01

    Electrocardiogram (ECG) monitoring is a critical tool in patient care, but its utility is often balanced with frustration from clinicians who are constantly distracted by false alarms. This has motivated the need to readdress the major factors that contribute to ECG noise with the goal of reducing false alarms. In this study, we describe a previously unreported phenomenon in which ECG noise can result from an unintended interaction between two systems: 1) the dc lead-off circuitry that is used to detect whether electrodes fall off the patient; and 2) the right-leg drive (RLD) system that is responsible for reducing ac common-mode noise that couples into the body. Using a circuit model to study this interaction, we found that in the presence of a dc lead-off system, even moderate increases in the right-leg skin-electrode resistance can cause the RLD amplifier to saturate. Such saturation can produce ECG noise because the RLD amplifier will no longer be capable of attenuating ac common-mode noise on the body. RLD saturation is particularly a problem for modern ECG monitors that use low-voltage supply levels. For example, for a 12-lead ECG and a 2 V power supply, saturation will occur when the right-leg electrode resistance reaches only 2 MΩ. We discuss several design solutions that can be used in low-voltage monitors to avoid RLD saturation.

  7. A harmonic linear dynamical system for prominent ECG feature extraction.

    PubMed

    Thi, Ngoc Anh Nguyen; Yang, Hyung-Jeong; Kim, SunHee; Do, Luu Ngoc

    2014-01-01

    Unsupervised mining of electrocardiography (ECG) time series is a crucial task in biomedical applications. To have efficiency of the clustering results, the prominent features extracted from preprocessing analysis on multiple ECG time series need to be investigated. In this paper, a Harmonic Linear Dynamical System is applied to discover vital prominent features via mining the evolving hidden dynamics and correlations in ECG time series. The discovery of the comprehensible and interpretable features of the proposed feature extraction methodology effectively represents the accuracy and the reliability of clustering results. Particularly, the empirical evaluation results of the proposed method demonstrate the improved performance of clustering compared to the previous main stream feature extraction approaches for ECG time series clustering tasks. Furthermore, the experimental results on real-world datasets show scalability with linear computation time to the duration of the time series.

  8. Evaluation of Digital Compressed Sensing for Real-Time Wireless ECG System with Bluetooth low Energy.

    PubMed

    Wang, Yishan; Doleschel, Sammy; Wunderlich, Ralf; Heinen, Stefan

    2016-07-01

    In this paper, a wearable and wireless ECG system is firstly designed with Bluetooth Low Energy (BLE). It can detect 3-lead ECG signals and is completely wireless. Secondly the digital Compressed Sensing (CS) is implemented to increase the energy efficiency of wireless ECG sensor. Different sparsifying basis, various compression ratio (CR) and several reconstruction algorithms are simulated and discussed. Finally the reconstruction is done by the android application (App) on smartphone to display the signal in real time. The power efficiency is measured and compared with the system without CS. The optimum satisfying basis built by 3-level decomposed db4 wavelet coefficients, 1-bit Bernoulli random matrix and the most suitable reconstruction algorithm are selected by the simulations and applied on the sensor node and App. The signal is successfully reconstructed and displayed on the App of smartphone. Battery life of sensor node is extended from 55 h to 67 h. The presented wireless ECG system with CS can significantly extend the battery life by 22 %. With the compact characteristic and long term working time, the system provides a feasible solution for the long term homecare utilization.

  9. The Zigbee wireless ECG measurement system design with a motion artifact remove algorithm by using adaptive filter and moving weighted factor

    NASA Astrophysics Data System (ADS)

    Kwon, Hyeokjun; Oh, Sechang; Varadan, Vijay K.

    2012-04-01

    The Electrocardiogram(ECG) signal is one of the bio-signals to check body status. Traditionally, the ECG signal was checked in the hospital. In these days, as the number of people who is interesting with periodic their health check increase, the requirement of self-diagnosis system development is being increased as well. Ubiquitous concept is one of the solutions of the self-diagnosis system. Zigbee wireless sensor network concept is a suitable technology to satisfy the ubiquitous concept. In measuring ECG signal, there are several kinds of methods in attaching electrode on the body called as Lead I, II, III, etc. In addition, several noise components occurred by different measurement situation such as experimenter's respiration, sensor's contact point movement, and the wire movement attached on sensor are included in pure ECG signal. Therefore, this paper is based on the two kinds of development concept. The first is the Zibee wireless communication technology, which can provide convenience and simpleness, and the second is motion artifact remove algorithm, which can detect clear ECG signal from measurement subject. The motion artifact created by measurement subject's movement or even respiration action influences to distort ECG signal, and the frequency distribution of the noises is around from 0.2Hz to even 30Hz. The frequencies are duplicated in actual ECG signal frequency, so it is impossible to remove the artifact without any distortion of ECG signal just by using low-pass filter or high-pass filter. The suggested algorithm in this paper has two kinds of main parts to extract clear ECG signal from measured original signal through an electrode. The first part is to extract motion noise signal from measured signal, and the second part is to extract clear ECG by using extracted motion noise signal and measured original signal. The paper suggests several techniques in order to extract motion noise signal such as predictability estimation theory, low pass filter, a filter including a moving weighted factor, peak to peak detection, and interpolation techniques. In addition, this paper introduces an adaptive filter in order to extract clear ECG signal by using extracted baseline noise signal and measured signal from sensor.

  10. A mixed signal ECG processing platform with an adaptive sampling ADC for portable monitoring applications.

    PubMed

    Kim, Hyejung; Van Hoof, Chris; Yazicioglu, Refet Firat

    2011-01-01

    This paper describes a mixed-signal ECG processing platform with an 12-bit ADC architecture that can adapt its sampling rate according to the input signals rate of change. This enables the sampling of ECG signals with significantly reduced data rate without loss of information. The presented adaptive sampling scheme reduces the ADC power consumption, enables the processing of ECG signals with lower power consumption, and reduces the power consumption of the radio while streaming the ECG signals. The test results show that running a CWT-based R peak detection algorithm using the adaptively sampled ECG signals consumes only 45.6 μW and it leads to 36% less overall system power consumption.

  11. A computer-human interaction model to improve the diagnostic accuracy and clinical decision-making during 12-lead electrocardiogram interpretation.

    PubMed

    Cairns, Andrew W; Bond, Raymond R; Finlay, Dewar D; Breen, Cathal; Guldenring, Daniel; Gaffney, Robert; Gallagher, Anthony G; Peace, Aaron J; Henn, Pat

    2016-12-01

    The 12-lead Electrocardiogram (ECG) presents a plethora of information and demands extensive knowledge and a high cognitive workload to interpret. Whilst the ECG is an important clinical tool, it is frequently incorrectly interpreted. Even expert clinicians are known to impulsively provide a diagnosis based on their first impression and often miss co-abnormalities. Given it is widely reported that there is a lack of competency in ECG interpretation, it is imperative to optimise the interpretation process. Predominantly the ECG interpretation process remains a paper based approach and whilst computer algorithms are used to assist interpreters by providing printed computerised diagnoses, there are a lack of interactive human-computer interfaces to guide and assist the interpreter. An interactive computing system was developed to guide the decision making process of a clinician when interpreting the ECG. The system decomposes the interpretation process into a series of interactive sub-tasks and encourages the clinician to systematically interpret the ECG. We have named this model 'Interactive Progressive based Interpretation' (IPI) as the user cannot 'progress' unless they complete each sub-task. Using this model, the ECG is segmented into five parts and presented over five user interfaces (1: Rhythm interpretation, 2: Interpretation of the P-wave morphology, 3: Limb lead interpretation, 4: QRS morphology interpretation with chest lead and rhythm strip presentation and 5: Final review of 12-lead ECG). The IPI model was implemented using emerging web technologies (i.e. HTML5, CSS3, AJAX, PHP and MySQL). It was hypothesised that this system would reduce the number of interpretation errors and increase diagnostic accuracy in ECG interpreters. To test this, we compared the diagnostic accuracy of clinicians when they used the standard approach (control cohort) with clinicians who interpreted the same ECGs using the IPI approach (IPI cohort). For the control cohort, the (mean; standard deviation; confidence interval) of the ECG interpretation accuracy was (45.45%; SD=18.1%; CI=42.07, 48.83). The mean ECG interpretation accuracy rate for the IPI cohort was 58.85% (SD=42.4%; CI=49.12, 68.58), which indicates a positive mean difference of 13.4%. (CI=4.45, 22.35) An N-1 Chi-square test of independence indicated a 92% chance that the IPI cohort will have a higher accuracy rate. Interpreter self-rated confidence also increased between cohorts from a mean of 4.9/10 in the control cohort to 6.8/10 in the IPI cohort (p=0.06). Whilst the IPI cohort had greater diagnostic accuracy, the duration of ECG interpretation was six times longer when compared to the control cohort. We have developed a system that segments and presents the ECG across five graphical user interfaces. Results indicate that this approach improves diagnostic accuracy but with the expense of time, which is a valuable resource in medical practice. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Microelectronic bioinstrumentation systems

    NASA Technical Reports Server (NTRS)

    Ko, W. H.

    1976-01-01

    Progress was made in the development of an RF cage, a single channel RF powered ECG telemetry system, and a three channel RF powered ECG, aortic blood pressure, and body temperature telemetry system. Encapsulation materials for chronic implantation of electronic circuits in the body were also evaluated.

  13. Variable threshold method for ECG R-peak detection.

    PubMed

    Kew, Hsein-Ping; Jeong, Do-Un

    2011-10-01

    In this paper, a wearable belt-type ECG electrode worn around the chest by measuring the real-time ECG is produced in order to minimize the inconvenient in wearing. ECG signal is detected using a potential instrument system. The measured ECG signal is transmits via an ultra low power consumption wireless data communications unit to personal computer using Zigbee-compatible wireless sensor node. ECG signals carry a lot of clinical information for a cardiologist especially the R-peak detection in ECG. R-peak detection generally uses the threshold value which is fixed. There will be errors in peak detection when the baseline changes due to motion artifacts and signal size changes. Preprocessing process which includes differentiation process and Hilbert transform is used as signal preprocessing algorithm. Thereafter, variable threshold method is used to detect the R-peak which is more accurate and efficient than fixed threshold value method. R-peak detection using MIT-BIH databases and Long Term Real-Time ECG is performed in this research in order to evaluate the performance analysis.

  14. Variation in the Use of 12‐Lead Electrocardiography for Patients With Chest Pain by Emergency Medical Services in North Carolina

    PubMed Central

    Bush, Montika; Glickman, Lawrence T.; Fernandez, Antonio R.; Garvey, J. L.; Glickman, Seth W.

    2013-01-01

    Background Prehospital 12‐lead electrocardiography (ECG) is critical to timely STEMI care although its use remains inconsistent. Previous studies to identify reasons for failure to obtain a prehospital ECG have generally only focused on individual emergency medical service (EMS) systems in urban areas. Our study objective was to identify patient, geographic, and EMS agency‐related factors associated with failure to perform a prehospital ECG across a statewide geography. Methods and Results We analyzed data from the Prehospital Medical Information System (PreMIS) in North Carolina from January 2008 to November 2010 for patients >30 years of age who used EMS and had a prehospital chief complaint of chest pain. Among 3.1 million EMS encounters, 134 350 patients met study criteria. From 2008–2010, 82 311 (61%) persons with chest pain received a prehospital ECG; utilization increased from 55% in 2008 to 65% in 2010 (trend P<0.001). Utilization by health referral region ranged from 22.9% to 74.2% and was lowest in rural areas. Men were more likely than women to have an ECG performed (63.0% vs 61.3%, adjusted RR 1.02, 95% CI 1.01 to 1.04). The certification‐level of the EMS provider (paramedic vsbasic/intermediate) and system‐level ECG equipment availability were the strongest predictors of ECG utilization. Persons in an ambulance with a certified paramedic were significantly more likely to receive a prehospital ECG than nonparamedics (RR 2.15, 95% CI 1.55, 2.99). Conclusions Across a large geographic area prehospital ECG use increased significantly, although important quality improvement opportunities remain. Increasing ECG availability and improving EMS certification and training levels are needed to improve overall care and reduce rural‐urban treatment differences. PMID:23920232

  15. An intelligent telecardiology system using a wearable and wireless ECG to detect atrial fibrillation.

    PubMed

    Lin, Chin-Teng; Chang, Kuan-Cheng; Lin, Chun-Ling; Chiang, Chia-Cheng; Lu, Shao-Wei; Chang, Shih-Sheng; Lin, Bor-Shyh; Liang, Hsin-Yueh; Chen, Ray-Jade; Lee, Yuan-Teh; Ko, Li-Wei

    2010-05-01

    This study presents a novel wireless, ambulatory, real-time, and autoalarm intelligent telecardiology system to improve healthcare for cardiovascular disease, which is one of the most prevalent and costly health problems in the world. This system consists of a lightweight and power-saving wireless ECG device equipped with a built-in automatic warning expert system. This device is connected to a mobile and ubiquitous real-time display platform. The acquired ECG signals are instantaneously transmitted to mobile devices, such as netbooks or mobile phones through Bluetooth, and then, processed by the expert system. An alert signal is sent to the remote database server, which can be accessed by an Internet browser, once an abnormal ECG is detected. The current version of the expert system can identify five types of abnormal cardiac rhythms in real-time, including sinus tachycardia, sinus bradycardia, wide QRS complex, atrial fibrillation (AF), and cardiac asystole, which is very important for both the subjects who are being monitored and the healthcare personnel tracking cardiac-rhythm disorders. The proposed system also activates an emergency medical alarm system when problems occur. Clinical testing reveals that the proposed system is approximately 94% accurate, with high sensitivity, specificity, and positive prediction rates for ten normal subjects and 20 AF patients. We believe that in the future a business-card-like ECG device, accompanied with a mobile phone, can make universal cardiac protection service possible.

  16. Accurate ECG diagnosis of atrial tachyarrhythmias using quantitative analysis: a prospective diagnostic and cost-effectiveness study.

    PubMed

    Krummen, David E; Patel, Mitul; Nguyen, Hong; Ho, Gordon; Kazi, Dhruv S; Clopton, Paul; Holland, Marian C; Greenberg, Scott L; Feld, Gregory K; Faddis, Mitchell N; Narayan, Sanjiv M

    2010-11-01

    Quantitative ECG Analysis. Optimal atrial tachyarrhythmia management is facilitated by accurate electrocardiogram interpretation, yet typical atrial flutter (AFl) may present without sawtooth F-waves or RR regularity, and atrial fibrillation (AF) may be difficult to separate from atypical AFl or rapid focal atrial tachycardia (AT). We analyzed whether improved diagnostic accuracy using a validated analysis tool significantly impacts costs and patient care. We performed a prospective, blinded, multicenter study using a novel quantitative computerized algorithm to identify atrial tachyarrhythmia mechanism from the surface ECG in patients referred for electrophysiology study (EPS). In 122 consecutive patients (age 60 ± 12 years) referred for EPS, 91 sustained atrial tachyarrhythmias were studied. ECGs were also interpreted by 9 physicians from 3 specialties for comparison and to allow healthcare system modeling. Diagnostic accuracy was compared to the diagnosis at EPS. A Markov model was used to estimate the impact of improved arrhythmia diagnosis. We found 13% of typical AFl ECGs had neither sawtooth flutter waves nor RR regularity, and were misdiagnosed by the majority of clinicians (0/6 correctly diagnosed by consensus visual interpretation) but correctly by quantitative analysis in 83% (5/6, P = 0.03). AF diagnosis was also improved through use of the algorithm (92%) versus visual interpretation (primary care: 76%, P < 0.01). Economically, we found that these improvements in diagnostic accuracy resulted in an average cost-savings of $1,303 and 0.007 quality-adjusted-life-years per patient. Typical AFl and AF are frequently misdiagnosed using visual criteria. Quantitative analysis improves diagnostic accuracy and results in improved healthcare costs and patient outcomes. © 2010 Wiley Periodicals, Inc.

  17. Application of exercise ECG stress test in the current high cost modern-era healthcare system.

    PubMed

    Vaidya, Gaurang Nandkishor

    Exercise electrocardiogram (ECG) tests boasts of being more widely available, less resource intensive, lower cost and absence of radiation. In the presence of a normal baseline ECG, an exercise ECG test is able to generate a reliable and reproducible result almost comparable to Technitium-99m sestamibi perfusion imaging. Exercise ECG changes when combined with other clinical parameters obtained during the test has the potential to allow effective redistribution of scarce resources by excluding low risk patients with significant accuracy. As we look towards a future of rising healthcare costs, increased prevalence of cardiovascular disease and the need for proper allocation of limited resources; exercise ECG test offers low cost, vital and reliable disease interpretation. This article highlights the physiology of the exercise ECG test, patient selection, effective interpretation, describe previously reported scores and their clinical application in today's clinical practice. Copyright © 2017. Published by Elsevier B.V.

  18. Performance study of the wearable one-lead wireless electrocardiographic monitoring system.

    PubMed

    Hong, Sungyoup; Yang, Yougmo; Kim, Seunghwan; Shin, Seungcheol; Lee, Inbum; Jang, Yongwon; Kim, Kiseong; Yi, Hwayeon

    2009-03-01

    This study attempts to compare and assess the performance of a wearable electrocardiogram (ECG) using a sensing fabric electrode and a Bluetooth network with a conventional ECG. A one-lead ECG examination was performed using Bioshirt and an iWorx 214 while walking or running at 3, 6, and 9 km per hour. A correlation coefficient of a heart rate variability (HRV) between these two devices was higher than 0.96 and power spectral density of HRV measured also showed an excellent agreement. Thus, both of these two ECG devices showed similar detection capability for R peaks. The measured values for wave duration and intervals of both devices concur with each other. The intensity of noise is controversial. The ECG device using a sensing fabric electrode and a wireless network showed an ECG signal detection and transmission capability similar to that of a conventional ECG device.

  19. Interactive Videoconference Supported Teaching in Undergraduate Nursing: A Case Study for ECG

    ERIC Educational Resources Information Center

    Celikkan, Ufuk; Senuzun, Fisun; Sari, Dilek; Sahin, Yasar Guneri

    2013-01-01

    This paper describes how interactive videoconference can benefit the Electrocardiography (ECG) skills of undergraduate nursing students. We have implemented a learning system that interactively transfers the visual and practical aspects of ECG from a nursing skills lab into a classroom where the theoretical part of the course is taught. The…

  20. A low-power and miniaturized electrocardiograph data collection system with smart textile electrodes for monitoring of cardiac function.

    PubMed

    Dai, Ming; Xiao, Xueliang; Chen, Xin; Lin, Haoming; Wu, Wanqing; Chen, Siping

    2016-12-01

    With the increasing aging population as well as health concerns, chronic heart disease has become the focus of public attention. A comfortable, low-powered, and wearable electrocardiogram (ECG) system for continuously monitoring the elderly's ECG signals over several hours is important for preventing cardiovascular diseases. Traditional ECG monitoring apparatus is often inconvenient to carry, has many electrodes to attach to the chest, and has a high-power consumption. There is also a challenge to design an electrocardiograph that satisfies requirements such as comfort, confinement, and compactness. Based on these considerations, this study presents a biosensor acquisition system for wearable, ubiquitous healthcare applications using three textile electrodes and a recording circuit specialized for ECG monitoring. In addition, several methods were adopted to reduce the power consumption of the device. The proposed system is composed of three parts: (1) an ECG analog front end (AFE), (2) digital signal processing and micro-control circuits, and (3) system software. Digital filter methods were used to eliminate the baseline wander, skin contact noise, and other interfering signals. A comparative study was conducted using this system to observe its performance with two commercial Holter monitors. The experimental results demonstrated that the total power consumption of this proposed system in a full round of ECG acquisition was only 29.74 mW. In addition, this low-power system performed well and stably measured the heart rate with an accuracy of 98.55 %. It can also contain a real-time dynamic display with organic light-emitting diodes (OLED) and wirelessly transmit information via a Bluetooth 4.0 module.

  1. From Pacemaker to Wearable: Techniques for ECG Detection Systems.

    PubMed

    Kumar, Ashish; Komaragiri, Rama; Kumar, Manjeet

    2018-01-11

    With the alarming rise in the deaths due to cardiovascular diseases (CVD), present medical research scenario places notable importance on techniques and methods to detect CVDs. As adduced by world health organization, technological proceeds in the field of cardiac function assessment have become the nucleus and heart of all leading research studies in CVDs in which electrocardiogram (ECG) analysis is the most functional and convenient tool used to test the range of heart-related irregularities. Most of the approaches present in the literature of ECG signal analysis consider noise removal, rhythm-based analysis, and heartbeat detection to improve the performance of a cardiac pacemaker. Advancements achieved in the field of ECG segments detection and beat classification have a limited evaluation and still require clinical approvals. In this paper, approaches on techniques to implement on-chip ECG detector for a cardiac pacemaker system are discussed. Moreover, different challenges regarding the ECG signal morphology analysis deriving from medical literature is extensively reviewed. It is found that robustness to noise, wavelet parameter choice, numerical efficiency, and detection performance are essential performance indicators required by a state-of-the-art ECG detector. Furthermore, many algorithms described in the existing literature are not verified using ECG data from the standard databases. Some ECG detection algorithms show very high detection performance with the total number of detected QRS complexes. However, the high detection performance of the algorithm is verified using only a few datasets. Finally, gaps in current advancements and testing are identified, and the primary challenge remains to be implementing bullseye test for morphology analysis evaluation.

  2. Implementation of a portable device for real-time ECG signal analysis.

    PubMed

    Jeon, Taegyun; Kim, Byoungho; Jeon, Moongu; Lee, Byung-Geun

    2014-12-10

    Cardiac disease is one of the main causes of catastrophic mortality. Therefore, detecting the symptoms of cardiac disease as early as possible is important for increasing the patient's survival. In this study, a compact and effective architecture for detecting atrial fibrillation (AFib) and myocardial ischemia is proposed. We developed a portable device using this architecture, which allows real-time electrocardiogram (ECG) signal acquisition and analysis for cardiac diseases. A noisy ECG signal was preprocessed by an analog front-end consisting of analog filters and amplifiers before it was converted into digital data. The analog front-end was minimized to reduce the size of the device and power consumption by implementing some of its functions with digital filters realized in software. With the ECG data, we detected QRS complexes based on wavelet analysis and feature extraction for morphological shape and regularity using an ARM processor. A classifier for cardiac disease was constructed based on features extracted from a training dataset using support vector machines. The classifier then categorized the ECG data into normal beats, AFib, and myocardial ischemia. A portable ECG device was implemented, and successfully acquired and processed ECG signals. The performance of this device was also verified by comparing the processed ECG data with high-quality ECG data from a public cardiac database. Because of reduced computational complexity, the ARM processor was able to process up to a thousand samples per second, and this allowed real-time acquisition and diagnosis of heart disease. Experimental results for detection of heart disease showed that the device classified AFib and ischemia with a sensitivity of 95.1% and a specificity of 95.9%. Current home care and telemedicine systems have a separate device and diagnostic service system, which results in additional time and cost. Our proposed portable ECG device provides captured ECG data and suspected waveform to identify sporadic and chronic events of heart diseases. This device has been built and evaluated for high quality of signals, low computational complexity, and accurate detection.

  3. On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals.

    PubMed

    Sahoo, Prasan Kumar; Thakkar, Hiren Kumar; Lin, Wen-Yen; Chang, Po-Cheng; Lee, Ming-Yih

    2018-01-28

    Cardiovascular disease (CVD) is a major public concern and socioeconomic problem across the globe. The popular high-end cardiac health monitoring systems such as magnetic resonance imaging (MRI), computerized tomography scan (CT scan), and echocardiography (Echo) are highly expensive and do not support long-term continuous monitoring of patients without disrupting their activities of daily living (ADL). In this paper, the continuous and non-invasive cardiac health monitoring using unobtrusive sensors is explored aiming to provide a feasible and low-cost alternative to foresee possible cardiac anomalies in an early stage. It is learned that cardiac health monitoring based on sole usage of electrocardiogram (ECG) signals may not provide powerful insights as ECG provides shallow information on various cardiac activities in the form of electrical impulses only. Hence, a novel low-cost, non-invasive seismocardiogram (SCG) signal along with ECG signals are jointly investigated for the robust cardiac health monitoring. For this purpose, the in-laboratory data collection model is designed for simultaneous acquisition of ECG and SCG signals followed by mechanisms for the automatic delineation of relevant feature points in acquired ECG and SCG signals. In addition, separate feature points based novel approach is adopted to distinguish between normal and abnormal morphology in each ECG and SCG cardiac cycle. Finally, a combined analysis of ECG and SCG is carried out by designing a Naïve Bayes conditional probability model. Experiments on Institutional Review Board (IRB) approved licensed ECG/SCG signals acquired from real subjects containing 12,000 cardiac cycles show that the proposed feature point delineation mechanisms and abnormal morphology detection methods consistently perform well and give promising results. In addition, experimental results show that the combined analysis of ECG and SCG signals provide more reliable cardiac health monitoring compared to the standalone use of ECG and SCG.

  4. On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals

    PubMed Central

    Lin, Wen-Yen; Chang, Po-Cheng

    2018-01-01

    Cardiovascular disease (CVD) is a major public concern and socioeconomic problem across the globe. The popular high-end cardiac health monitoring systems such as magnetic resonance imaging (MRI), computerized tomography scan (CT scan), and echocardiography (Echo) are highly expensive and do not support long-term continuous monitoring of patients without disrupting their activities of daily living (ADL). In this paper, the continuous and non-invasive cardiac health monitoring using unobtrusive sensors is explored aiming to provide a feasible and low-cost alternative to foresee possible cardiac anomalies in an early stage. It is learned that cardiac health monitoring based on sole usage of electrocardiogram (ECG) signals may not provide powerful insights as ECG provides shallow information on various cardiac activities in the form of electrical impulses only. Hence, a novel low-cost, non-invasive seismocardiogram (SCG) signal along with ECG signals are jointly investigated for the robust cardiac health monitoring. For this purpose, the in-laboratory data collection model is designed for simultaneous acquisition of ECG and SCG signals followed by mechanisms for the automatic delineation of relevant feature points in acquired ECG and SCG signals. In addition, separate feature points based novel approach is adopted to distinguish between normal and abnormal morphology in each ECG and SCG cardiac cycle. Finally, a combined analysis of ECG and SCG is carried out by designing a Naïve Bayes conditional probability model. Experiments on Institutional Review Board (IRB) approved licensed ECG/SCG signals acquired from real subjects containing 12,000 cardiac cycles show that the proposed feature point delineation mechanisms and abnormal morphology detection methods consistently perform well and give promising results. In addition, experimental results show that the combined analysis of ECG and SCG signals provide more reliable cardiac health monitoring compared to the standalone use of ECG and SCG. PMID:29382098

  5. Signal loss during fetal heart rate monitoring using maternal abdominal surface electrodes between 28 and 42 weeks of pregnancy.

    PubMed

    Fuchs, Tomasz; Pomorski, Michał; Grobelak, Krzysztof; Tomiałowicz, Marek; Zimmer, Mariusz

    2014-01-01

    Fetal electrocardiography is one of the methods for monitoring the well-being of the fetus. Signal loss limits the proper interpretation of electrocardiogram traces. The aim of this study was to assess the average signal loss in non-invasive abdominal fetal electrocardiogram (fECG) monitoring using the KOMPOREL fetal monitoring system (ITAM, Zabrze, Poland) in women between 28 and 42 week of pregnancy. The results were compared to FIGO (International Federation of Gynaecology and Obstetric) and DGGG (Deutsche Gesellschaft für Gynäkologie und Geburtshilfe e.V.) recommendations concerning fetal heart monitoring. The correlation between fetal ECG signal quality, week of pregnancy and patient BMI was evaluated. 773 pregnant women, hospitalized and diagnosed in the Department of Gynecology and Obstetrics, Wroclaw Medical University, underwent 30 min of abdominal fECG recordings using the KOMPOREL fetal monitoring system. The average signal loss in abdominal fECG monitoring in the study group was 32%. FIGO recommendations describe an acceptable fetal signal loss of 20%. In our study, 46% (357/773) of the recordings were up to FIGO standards, with fetal heart rate success rates above 80%. According to DGGG guidelines, with acceptable fetal signal loss of 15%, only 39% (303/773) of the recordings could be assessed as accurate. No correlation between fECG signal quality, week of pregnancy and patient BMI was proved. The average signal loss in abdominal fECG monitoring in our study group was 32%. Low fECG signal quality may constitute a potentially limiting factor of the described fetal heart monitoring system. No relationship between fECG signal quality, week of pregnancy and patient BMI was proved.

  6. A decision support system and rule-based algorithm to augment the human interpretation of the 12-lead electrocardiogram.

    PubMed

    Cairns, Andrew W; Bond, Raymond R; Finlay, Dewar D; Guldenring, Daniel; Badilini, Fabio; Libretti, Guido; Peace, Aaron J; Leslie, Stephen J

    The 12-lead Electrocardiogram (ECG) has been used to detect cardiac abnormalities in the same format for more than 70years. However, due to the complex nature of 12-lead ECG interpretation, there is a significant cognitive workload required from the interpreter. This complexity in ECG interpretation often leads to errors in diagnosis and subsequent treatment. We have previously reported on the development of an ECG interpretation support system designed to augment the human interpretation process. This computerised decision support system has been named 'Interactive Progressive based Interpretation' (IPI). In this study, a decision support algorithm was built into the IPI system to suggest potential diagnoses based on the interpreter's annotations of the 12-lead ECG. We hypothesise semi-automatic interpretation using a digital assistant can be an optimal man-machine model for ECG interpretation. To improve interpretation accuracy and reduce missed co-abnormalities. The Differential Diagnoses Algorithm (DDA) was developed using web technologies where diagnostic ECG criteria are defined in an open storage format, Javascript Object Notation (JSON), which is queried using a rule-based reasoning algorithm to suggest diagnoses. To test our hypothesis, a counterbalanced trial was designed where subjects interpreted ECGs using the conventional approach and using the IPI+DDA approach. A total of 375 interpretations were collected. The IPI+DDA approach was shown to improve diagnostic accuracy by 8.7% (although not statistically significant, p-value=0.1852), the IPI+DDA suggested the correct interpretation more often than the human interpreter in 7/10 cases (varying statistical significance). Human interpretation accuracy increased to 70% when seven suggestions were generated. Although results were not found to be statistically significant, we found; 1) our decision support tool increased the number of correct interpretations, 2) the DDA algorithm suggested the correct interpretation more often than humans, and 3) as many as 7 computerised diagnostic suggestions augmented human decision making in ECG interpretation. Statistical significance may be achieved by expanding sample size. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography

    PubMed Central

    Penzel, Thomas; Kantelhardt, Jan W.; Bartsch, Ronny P.; Riedl, Maik; Kraemer, Jan F.; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph

    2016-01-01

    The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave). PMID:27826247

  8. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography.

    PubMed

    Penzel, Thomas; Kantelhardt, Jan W; Bartsch, Ronny P; Riedl, Maik; Kraemer, Jan F; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph

    2016-01-01

    The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave).

  9. The chaos and order in human ECG under the influence of the external perturbations

    NASA Astrophysics Data System (ADS)

    Ragulskaya, Maria; Valeriy, Pipin

    The results of the many-year telecommunication heliomedical monitoring "Heliomed" show, that space weather and geophysical factor variations serve as a training factor for the adaptation-resistant member of the human population. Here we discuss the specific properties of the human ECG discovered in our experiment. The program "Heliomed" is carried out simultaneously at the different geographical areas that cover the different latitudes. The daily registered param-eters include: the psycho-emotional tests and the 1-st lead ECG, the arterial pressure, the variability cardiac contraction, the electric conduction of bioactive points on skin. The results time series compared with daily values of space weather and geomagnetic parameters. The analysis of ECG signal proceeds as follows. At first step we construct the ECG embedding into 3D phase space using the first 3 Principal Components of the ECG time series. Next, we divide ECG on the separate cycles using the maxima of the ECG's QRS complex. Then, we filter out the non-typical ECG beats by means of the Housdorff distance. Finally, we average the example of the ECG time series along the reference trajectory and study of the dynamical characteristics of the averaged ECG beat. It is found, that the ECG signal embeded in 3D phase space can be considered as a mix of a few states. At the rest, the occurrence of the primary ECG state compare to additional ones is about 8:2. The occurrence of the primary state increases after the stress. The main effect of the external perturbation is observed in structural change of the cardio-cycle and not in the variability of the R-R interval. The num-ber of none-typical cycles increase during an isolated magnetic storm. At the all monitoring centers participating experiment the same type of changes in the cardiac activity parameters is detected to go nearly simultaneously during an isolated magnetic storm. To understand the origin of the standard cardio-cycle changes we use the dynamical model reconstruction of the individual cardiac beat. It is found that the positions of the stationary points of the typical ECG attractor are in vicinities of Q and T waves. Additionally, we find that the stiffness of the beat is important for the general stability of ECG. The given results agues for the increase the relative disorder of the human cardiac system under external perturbations due to changes in the space weather and climatic factors. Also, the results of monitoring show that cardiac system can be stabilized by "internal" (physical) stress. The given difference in the cardiac sys-tem behavior under the different types of stress is obtained in the earth labaratory conditions. However, it should be considered as important factors influencing on the health of cosmonauts during the space missions, as well.

  10. Noise-aware dictionary-learning-based sparse representation framework for detection and removal of single and combined noises from ECG signal

    PubMed Central

    Ramkumar, Barathram; Sabarimalai Manikandan, M.

    2017-01-01

    Automatic electrocardiogram (ECG) signal enhancement has become a crucial pre-processing step in most ECG signal analysis applications. In this Letter, the authors propose an automated noise-aware dictionary learning-based generalised ECG signal enhancement framework which can automatically learn the dictionaries based on the ECG noise type for effective representation of ECG signal and noises, and can reduce the computational load of sparse representation-based ECG enhancement system. The proposed framework consists of noise detection and identification, noise-aware dictionary learning, sparse signal decomposition and reconstruction. The noise detection and identification is performed based on the moving average filter, first-order difference, and temporal features such as number of turning points, maximum absolute amplitude, zerocrossings, and autocorrelation features. The representation dictionary is learned based on the type of noise identified in the previous stage. The proposed framework is evaluated using noise-free and noisy ECG signals. Results demonstrate that the proposed method can significantly reduce computational load as compared with conventional dictionary learning-based ECG denoising approaches. Further, comparative results show that the method outperforms existing methods in automatically removing noises such as baseline wanders, power-line interference, muscle artefacts and their combinations without distorting the morphological content of local waves of ECG signal. PMID:28529758

  11. Noise-aware dictionary-learning-based sparse representation framework for detection and removal of single and combined noises from ECG signal.

    PubMed

    Satija, Udit; Ramkumar, Barathram; Sabarimalai Manikandan, M

    2017-02-01

    Automatic electrocardiogram (ECG) signal enhancement has become a crucial pre-processing step in most ECG signal analysis applications. In this Letter, the authors propose an automated noise-aware dictionary learning-based generalised ECG signal enhancement framework which can automatically learn the dictionaries based on the ECG noise type for effective representation of ECG signal and noises, and can reduce the computational load of sparse representation-based ECG enhancement system. The proposed framework consists of noise detection and identification, noise-aware dictionary learning, sparse signal decomposition and reconstruction. The noise detection and identification is performed based on the moving average filter, first-order difference, and temporal features such as number of turning points, maximum absolute amplitude, zerocrossings, and autocorrelation features. The representation dictionary is learned based on the type of noise identified in the previous stage. The proposed framework is evaluated using noise-free and noisy ECG signals. Results demonstrate that the proposed method can significantly reduce computational load as compared with conventional dictionary learning-based ECG denoising approaches. Further, comparative results show that the method outperforms existing methods in automatically removing noises such as baseline wanders, power-line interference, muscle artefacts and their combinations without distorting the morphological content of local waves of ECG signal.

  12. [Evaluation of a registration card for logging electrocardiographic records into standard personal computers].

    PubMed

    Pizzuti, A; Baralis, G; Bassignana, A; Antonielli, E; Di Leo, M

    1997-01-01

    The MS200 Cardioscope, from MRT Micro as., Norway, is a 12 channel ECG card to be directly inserted into a standard personal computer (PC). The standard ISA Bus compatible half length card comes with a set of 10 cables with electrodes and the software for recording, displaying and saving ECG signals. The system is supplied with DOS or Windows software. The goal of the present work was to evaluate the affordability and usability of the MS200 in a clinical setting. We tested the 1.5 DOS version of the software. In 30 patients with various cardiac diseases the ECG signal has been recorded with MS200 and with standard Hellige CardioSmart equipment. The saved ECGs were recalled and printed using an Epson Stylus 800 ink-jet printer. Two cardiologists reviewed the recordings for a looking at output quality, amplitude and speed precision, artifacts, etc. 1) Installation: the card has proven to be totally compatible with the hardware; no changes in default settings had to be made. 2) Usage: the screens are clear; the commands and menus are intuitive and easy to use. Due to the boot-strap and software loading procedures and, most important, off-line printing, the time needed to obtain a complete ECG printout has been longer than that of the reference machine. 3) Archiving and retrieval of ECG: the ECG curves can be saved in original or compressed form: selecting the latter, the noise and non-ECG information is filtered away and the space consumption on disk is reduced: on average, 20 Kb are needed for 10 seconds of signal. The MS200 can be run on a Local Area Network and is prepared for integrating with an existing informative system: we are currently testing the system in this scenery. 4) MS200 includes options for on-line diagnosis, a technology we have not tested in the present work. 5) The only setting allowed for printing full pages is letter size (A4): the quality of printouts is good, with a resolution of 180 DPI. In conclusion, the MS200 system seems reliable and safe. In the configuration we tested, it cannot substitute a dedicated ECG equipment: from this point of view, a smaller PCMCIA-type card with a battery-operated notebook PC will be more suitable for clinical uses. Nevertheless, the possibility to log and track ECG records, integrated into the department informative system, may provide a valuable tool for improving access to medical information.

  13. Compressed sensing system considerations for ECG and EMG wireless biosensors.

    PubMed

    Dixon, Anna M R; Allstot, Emily G; Gangopadhyay, Daibashish; Allstot, David J

    2012-04-01

    Compressed sensing (CS) is an emerging signal processing paradigm that enables sub-Nyquist processing of sparse signals such as electrocardiogram (ECG) and electromyogram (EMG) biosignals. Consequently, it can be applied to biosignal acquisition systems to reduce the data rate to realize ultra-low-power performance. CS is compared to conventional and adaptive sampling techniques and several system-level design considerations are presented for CS acquisition systems including sparsity and compression limits, thresholding techniques, encoder bit-precision requirements, and signal recovery algorithms. Simulation studies show that compression factors greater than 16X are achievable for ECG and EMG signals with signal-to-quantization noise ratios greater than 60 dB.

  14. ECG interpretation skills of South African Emergency Medicine residents

    PubMed Central

    Wallis, Lee; Maritz, David

    2010-01-01

    Background The use and interpretation of electrocardiograms (ECGs) are widely accepted as an essential core skill in Emergency Medicine. It is imperative that emergency physicians are expert in ECG interpretation when they exit their training programme. Aim It is unknown whether South African Emergency Medicine trainees are getting the necessary skills in ECG interpretation during the training programme. Currently there are no clear criteria to assess emergency physicians’ competency in ECG interpretation in South Africa. Methods A prospective cross-sectional study of Emergency Medicine residents and recently qualified emergency physicians was conducted between August 2008 and February 2009 using a focused questionnaire. Results At the time of the study, there were 55 eligible trainees in South Africa. A total of 55 assessments were distributed; 50 were returned (91%) and 49 were fully completed (89%). In this study, we found the overall average score of ECG interpretation was 46.4% [95% confidence interval (CI) 41.5–51.2%]. The junior group had an overall average of 42.2% (95% CI 36.9–47.5%), whereas the senior group managed 52.5% (95% CI 43.4–61.5%). Conclusion In this prospective cross-sectional study of Emergency Medicine residents and recently qualified emergency physicians, we found that there was improvement in the interpretation of ECGs with increased seniority. There exists, however, a low level of accuracy for many of the critical ECG diagnoses. The average score of 46.4% obtained in this study is lower than the scores obtained by other international studies from countries where Emergency Medicine is a well-established speciality. PMID:21373298

  15. An Interoperable System toward Cardiac Risk Stratification from ECG Monitoring

    PubMed Central

    Mora-Jiménez, Inmaculada; Ramos-López, Javier; Quintanilla Fernández, Teresa; García-García, Antonio; Díez-Mazuela, Daniel; García-Alberola, Arcadi

    2018-01-01

    Many indices have been proposed for cardiovascular risk stratification from electrocardiogram signal processing, still with limited use in clinical practice. We created a system integrating the clinical definition of cardiac risk subdomains from ECGs and the use of diverse signal processing techniques. Three subdomains were defined from the joint analysis of the technical and clinical viewpoints. One subdomain was devoted to demographic and clinical data. The other two subdomains were intended to obtain widely defined risk indices from ECG monitoring: a simple-domain (heart rate turbulence (HRT)), and a complex-domain (heart rate variability (HRV)). Data provided by the three subdomains allowed for the generation of alerts with different intensity and nature, as well as for the grouping and scrutinization of patients according to the established processing and risk-thresholding criteria. The implemented system was tested by connecting data from real-world in-hospital electronic health records and ECG monitoring by considering standards for syntactic (HL7 messages) and semantic interoperability (archetypes based on CEN/ISO EN13606 and SNOMED-CT). The system was able to provide risk indices and to generate alerts in the health records to support decision-making. Overall, the system allows for the agile interaction of research and clinical practice in the Holter-ECG-based cardiac risk domain. PMID:29494497

  16. A ECG Signal Gathering and Displaying System Based on AVR

    NASA Astrophysics Data System (ADS)

    Ning, Li; Ruilan, Zhang; Jian, Liu; Xiaochen, Wang; Shuying, Chen; Zhuolin, Lang

    2017-12-01

    This article introduces a kind of system which is based on the AVR to acquire the data of ECG. Such system using the A/D function of ATmega8 chip and the lattice graph LCD to design ECG heart acquisition satisfies the demands above. This design gives a composition of hardware and programming of software about the system in detail which has mainly realized the real-time gathering, the amplifier, the filter, the A/D transformation and the LCD display. Since the AVR includes A/D transformation function and support embedded C language programming, it reduces the peripheral circuit, further more it also decreases the time to design and debug this system.

  17. Standard-compliant real-time transmission of ECGs: harmonization of ISO/IEEE 11073-PHD and SCP-ECG.

    PubMed

    Trigo, Jesús D; Chiarugi, Franco; Alesanco, Alvaro; Martínez-Espronceda, Miguel; Chronaki, Catherine E; Escayola, Javier; Martínez, Ignacio; García, José

    2009-01-01

    Ambient assisted living and integrated care in an aging society is based on the vision of the lifelong Electronic Health Record calling for HealthCare Information Systems and medical device interoperability. For medical devices this aim can be achieved by the consistent implementation of harmonized international interoperability standards. The ISO/IEEE 11073 (x73) family of standards is a reference standard for medical device interoperability. In its Personal Health Device (PHD) version several devices have been included, but an ECG device specialization is not yet available. On the other hand, the SCP-ECG standard for short-term diagnostic ECGs (EN1064) has been recently approved as an international standard ISO/IEEE 11073-91064:2009. In this paper, the relationships between a proposed x73-PHD model for an ECG device and the fields of the SCP-ECG standard are investigated. A proof-of-concept implementation of the proposed x73-PHD ECG model is also presented, identifying open issues to be addressed by standards development for the wider interoperability adoption of x73-PHD standards.

  18. A Review on the Nonlinear Dynamical System Analysis of Electrocardiogram Signal

    PubMed Central

    Mohapatra, Biswajit

    2018-01-01

    Electrocardiogram (ECG) signal analysis has received special attention of the researchers in the recent past because of its ability to divulge crucial information about the electrophysiology of the heart and the autonomic nervous system activity in a noninvasive manner. Analysis of the ECG signals has been explored using both linear and nonlinear methods. However, the nonlinear methods of ECG signal analysis are gaining popularity because of their robustness in feature extraction and classification. The current study presents a review of the nonlinear signal analysis methods, namely, reconstructed phase space analysis, Lyapunov exponents, correlation dimension, detrended fluctuation analysis (DFA), recurrence plot, Poincaré plot, approximate entropy, and sample entropy along with their recent applications in the ECG signal analysis. PMID:29854361

  19. A Review on the Nonlinear Dynamical System Analysis of Electrocardiogram Signal.

    PubMed

    Nayak, Suraj K; Bit, Arindam; Dey, Anilesh; Mohapatra, Biswajit; Pal, Kunal

    2018-01-01

    Electrocardiogram (ECG) signal analysis has received special attention of the researchers in the recent past because of its ability to divulge crucial information about the electrophysiology of the heart and the autonomic nervous system activity in a noninvasive manner. Analysis of the ECG signals has been explored using both linear and nonlinear methods. However, the nonlinear methods of ECG signal analysis are gaining popularity because of their robustness in feature extraction and classification. The current study presents a review of the nonlinear signal analysis methods, namely, reconstructed phase space analysis, Lyapunov exponents, correlation dimension, detrended fluctuation analysis (DFA), recurrence plot, Poincaré plot, approximate entropy, and sample entropy along with their recent applications in the ECG signal analysis.

  20. Unveiling the Biometric Potential of Finger-Based ECG Signals

    PubMed Central

    Lourenço, André; Silva, Hugo; Fred, Ana

    2011-01-01

    The ECG signal has been shown to contain relevant information for human identification. Even though results validate the potential of these signals, data acquisition methods and apparatus explored so far compromise user acceptability, requiring the acquisition of ECG at the chest. In this paper, we propose a finger-based ECG biometric system, that uses signals collected at the fingers, through a minimally intrusive 1-lead ECG setup recurring to Ag/AgCl electrodes without gel as interface with the skin. The collected signal is significantly more noisy than the ECG acquired at the chest, motivating the application of feature extraction and signal processing techniques to the problem. Time domain ECG signal processing is performed, which comprises the usual steps of filtering, peak detection, heartbeat waveform segmentation, and amplitude normalization, plus an additional step of time normalization. Through a simple minimum distance criterion between the test patterns and the enrollment database, results have revealed this to be a promising technique for biometric applications. PMID:21837235

  1. Computer analysis of Holter electrocardiogram.

    PubMed

    Yanaga, T; Adachi, M; Sato, Y; Ichimaru, Y; Otsuka, K

    1994-10-01

    Computer analysis is indispensable for the interpretation of Holter ECG, because it includes a large quantity of data. Computer analysis of Holter ECG is similar to that of conventional ECG, however, in computer analysis of Holter ECG, there are some difficulties such as many noise, limited analyzing time and voluminous data. The main topics in computer analysis of Holter ECG will be arrhythmias, ST-T changes, heart rate variability, QT interval, late potential and construction of database. Although many papers have been published on the computer analysis of Holter ECG, some of the papers was reviewed briefly in the present paper. We have studied on computer analysis of VPCs, ST-T changes, heart rate variability, QT interval and Cheyne-Stokes respiration during 24-hour ambulatory ECG monitoring. Further, we have studied on ambulatory palmar sweating for the evaluation of mental stress during a day. In future, the development of "the integrated Holter system", which enables the evaluation of ventricular vulnerability and modulating factor such as psychoneural hypersensitivity may be important.

  2. Unveiling the biometric potential of finger-based ECG signals.

    PubMed

    Lourenço, André; Silva, Hugo; Fred, Ana

    2011-01-01

    The ECG signal has been shown to contain relevant information for human identification. Even though results validate the potential of these signals, data acquisition methods and apparatus explored so far compromise user acceptability, requiring the acquisition of ECG at the chest. In this paper, we propose a finger-based ECG biometric system, that uses signals collected at the fingers, through a minimally intrusive 1-lead ECG setup recurring to Ag/AgCl electrodes without gel as interface with the skin. The collected signal is significantly more noisy than the ECG acquired at the chest, motivating the application of feature extraction and signal processing techniques to the problem. Time domain ECG signal processing is performed, which comprises the usual steps of filtering, peak detection, heartbeat waveform segmentation, and amplitude normalization, plus an additional step of time normalization. Through a simple minimum distance criterion between the test patterns and the enrollment database, results have revealed this to be a promising technique for biometric applications.

  3. Digitization of Electrocardiogram From Telemetry Prior to In-hospital Cardiac Arrest: A Pilot Study.

    PubMed

    Attin, Mina; Wang, Lu; Soroushmehr, S M Reza; Lin, Chii-Dean; Lemus, Hector; Spadafore, Maxwell; Najarian, Kayvan

    2016-03-01

    Analyzing telemetry electrocardiogram (ECG) data over an extended period is often time-consuming because digital records are not widely available at hospitals. Investigating trends and patterns in the ECG data could lead to establishing predictors that would shorten response time to in-hospital cardiac arrest (I-HCA). This study was conducted to validate a novel method of digitizing paper ECG tracings from telemetry systems in order to facilitate the use of heart rate as a diagnostic feature prior to I-HCA. This multicenter study used telemetry to investigate full-disclosure ECG papers of 44 cardiovascular patients obtained within 1 hr of I-HCA with initial rhythms of pulseless electrical activity and asystole. Digital ECGs were available for seven of these patients. An algorithm to digitize the full-disclosure ECG papers was developed using the shortest path method. The heart rate was measured manually (averaging R-R intervals) for ECG papers and automatically for digitized and digital ECGs. Significant correlations were found between manual and automated measurements of digitized ECGs (p < .001) and between digitized and digital ECGs (p < .001). Bland-Altman methods showed bias = .001 s, SD = .0276 s, lower and upper 95% limits of agreement for digitized and digital ECGs = .055 and -.053 s, and percentage error = 0.22%. Root mean square (rms), percentage rms difference, and signal to noise ratio values were in acceptable ranges. The digitization method was validated. Digitized ECG provides an efficient and accurate way of measuring heart rate over an extended period of time. © The Author(s) 2015.

  4. [ECG for non-competitive sports in childhood: strengths and disputes].

    PubMed

    Poggi, Elena; Giannattasio, Alessandro; Bolloli, Sara; Beccaria, Andrea; Mezzano, Paola; Rocca, Paola; Del Vecchio, Cecilia

    2016-11-01

    Sport is very important for health promotion and conservation. Active lifestyle and regular exercise reduce cardiovascular disease incidence. The Italian Ministry of Health issued the Law Decree no. 243 (10/18/2014) concerning "guidelines for certification about non-competitive sports" to promote safety in sports. This regulation defines the activities for which a certificate is required, the professional actors involved and the clinical exams to be performed according to the patient's health status. In particular, the Law Decree recommends to perform an electrocardiogram (ECG) "at least once in a lifetime", introducing much greater news into pediatric practice. We proposed a survey evaluating frequency of ECG implementation for non-competitive sports and cardiovascular diseases incidence was administered to 7 Ligurian pediatricians. The number of ECG/year for pediatrician increased from 10 ECG/year to 50 ECG/year with an indication of suitability to non-competitive sports. One case of QT prolongation and 2 cases of type 1 Brugada ECG pattern were diagnosed. In addition, 3 patients had an atrial septal defect and 3 children had a ventricular septal defect. Forty-three percent of the pediatricians considered useful performing the ECG. ECG in children has enhanced the positive effects on the community health. However, it remains to be defined in agreement with scientific societies the age at which to perform ECG, the sports for which ECG is required and the cost-benefit ratio for the National Health System and families.

  5. Evaluation of outpatients experiencing implantable cardioverter defibrillator shocks associated with minimal symptoms.

    PubMed

    Hamer, M E; Clair, W K; Wilkinson, W E; Greenfield, R A; Pritchett, E L; Page, R L

    1994-05-01

    Patients receiving minimally symptomatic shocks from their implantable cardioverter defibrillators were studied prospectively using transtelephonic ECG loop monitoring. The time course to the first subsequent shock was evaluated. Twenty-nine consecutive patients who received a shock preceded by mild palpitations or no symptoms were given a transtelephonic ECG loop monitor and instructed to activate the monitor if a subsequent shock occurred. Kaplan-Meier analysis was used to quantitate the time to first shock during the study period. The point estimate +/- standard error of patients receiving a shock during the study period was 31% +/- 9% at 30 days, 41% +/- 9% at 60 days, and 60% +/- 9% at 120 days. The ECG was successfully transmitted in 7 of 13 patients who had shocks in the 60-day monitoring period, and demonstrated inappropriate shocks in 6 of 7. Determination of the cause of shock led to a change in subsequent management in all 7 patients. We conclude that the incidence of inappropriate shocks may be higher than estimated previously in patients with minimal symptoms prior to the shock. There are thousands of patients with implantable cardioverter defibrillators that have no storage function for treated tachycardias; transtelephonic ECG loop monitoring can determine the cause of implantable cardioverter defibrillator discharge in these patients, and the diagnosis is invaluable in their management.

  6. MS-QI: A Modulation Spectrum-Based ECG Quality Index for Telehealth Applications.

    PubMed

    Tobon V, Diana P; Falk, Tiago H; Maier, Martin

    2016-08-01

    As telehealth applications emerge, the need for accurate and reliable biosignal quality indices has increased. One typical modality used in remote patient monitoring is the electrocardiogram (ECG), which is inherently susceptible to several different noise sources, including environmental (e.g., powerline interference), experimental (e.g., movement artifacts), and physiological (e.g., muscle and breathing artifacts). Accurate measurement of ECG quality can allow for automated decision support systems to make intelligent decisions about patient conditions. This is particularly true for in-home monitoring applications, where the patient is mobile and the ECG signal can be severely corrupted by movement artifacts. In this paper, we propose an innovative ECG quality index based on the so-called modulation spectral signal representation. The representation quantifies the rate of change of ECG spectral components, which are shown to be different from the rate of change of typical ECG noise sources. The proposed modulation spectral-based quality index, MS-QI, was tested on 1) synthetic ECG signals corrupted by varying levels of noise, 2) single-lead recorded data using the Hexoskin garment during three activity levels (sitting, walking, running), 3) 12-lead recorded data using conventional ECG machines (Computing in Cardiology 2011 dataset), and 4) two-lead ambulatory ECG recorded from arrhythmia patients (MIT-BIH Arrhythmia Database). Experimental results showed the proposed index outperforming two conventional benchmark quality measures, particularly in the scenarios involving recorded data in real-world environments.

  7. Live ECG readings using Google Glass in emergency situations.

    PubMed

    Schaer, Roger; Salamin, Fanny; Jimenez Del Toro, Oscar Alfonso; Atzori, Manfredo; Muller, Henning; Widmer, Antoine

    2015-01-01

    Most sudden cardiac problems require rapid treatment to preserve life. In this regard, electrocardiograms (ECG) shown on vital parameter monitoring systems help medical staff to detect problems. In some situations, such monitoring systems may display information in a less than convenient way for medical staff. For example, vital parameters are displayed on large screens outside the field of view of a surgeon during cardiac surgery. This may lead to losing time and to mistakes when problems occur during cardiac operations. In this paper we present a novel approach to display vital parameters such as the second derivative of the ECG rhythm and heart rate close to the field of view of a surgeon using Google Glass. As a preliminary assessment, we run an experimental study to verify the possibility for medical staff to identify abnormal ECG rhythms from Google Glass. This study compares 6 ECG rhythms readings from a 13.3 inch laptop screen and from the prism of Google Glass. Seven medical residents in internal medicine participated in the study. The preliminary results show that there is no difference between identifying these 6 ECG rhythms from the laptop screen versus Google Glass. Both allow close to perfect identification of the 6 common ECG rhythms. This shows the potential of connected glasses such as Google Glass to be useful in selected medical applications.

  8. Arduino-based noise robust online heart-rate detection.

    PubMed

    Das, Sangita; Pal, Saurabh; Mitra, Madhuchhanda

    2017-04-01

    This paper introduces a noise robust real time heart rate detection system from electrocardiogram (ECG) data. An online data acquisition system is developed to collect ECG signals from human subjects. Heart rate is detected using window-based autocorrelation peak localisation technique. A low-cost Arduino UNO board is used to implement the complete automated process. The performance of the system is compared with PC-based heart rate detection technique. Accuracy of the system is validated through simulated noisy ECG data with various levels of signal to noise ratio (SNR). The mean percentage error of detected heart rate is found to be 0.72% for the noisy database with five different noise levels.

  9. Influence of ECG measurement accuracy on ECG diagnostic statements.

    PubMed

    Zywietz, C; Celikag, D; Joseph, G

    1996-01-01

    Computer analysis of electrocardiograms (ECGs) provides a large amount of ECG measurement data, which may be used for diagnostic classification and storage in ECG databases. Until now, neither error limits for ECG measurements have been specified nor has their influence on diagnostic statements been systematically investigated. An analytical method is presented to estimate the influence of measurement errors on the accuracy of diagnostic ECG statements. Systematic (offset) errors will usually result in an increase of false positive or false negative statements since they cause a shift of the working point on the receiver operating characteristics curve. Measurement error dispersion broadens the distribution function of discriminative measurement parameters and, therefore, usually increases the overlap between discriminative parameters. This results in a flattening of the receiver operating characteristics curve and an increase of false positive and false negative classifications. The method developed has been applied to ECG conduction defect diagnoses by using the proposed International Electrotechnical Commission's interval measurement tolerance limits. These limits appear too large because more than 30% of false positive atrial conduction defect statements and 10-18% of false intraventricular conduction defect statements could be expected due to tolerated measurement errors. To assure long-term usability of ECG measurement databases, it is recommended that systems provide its error tolerance limits obtained on a defined test set.

  10. An ECG electrode-mounted heart rate, respiratory rhythm, posture and behavior recording system.

    PubMed

    Yoshimura, Takahiro; Yonezawa, Yoshiharu; Maki, Hiromichi; Ogawa, Hidekuni; Ninomiya, Ishio; Morton Caldwell, W

    2004-01-01

    R-R interval, respiration rhythm, posture and behavior recording system has been developed for monitoring a patient's cardiovascular regulatory system in daily life. The recording system consists of three ECG chest electrodes, a variable gain instrumentation amplifier, a dual axis accelerometer, a low power 8-bit single-chip microcomputer and a 1024 KB EEPROM. The complete system is mounted on the chest electrodes. R-R interval and respiration rhythm are calculated by the R waves detected from the ECG. Posture and behavior such as walking and running are detected from the body movements recorded by the accelerometer. The detected data are stored by the EEPROM and, after recording, are downloaded to a desktop computer for analysis.

  11. A portable respiratory rate estimation system with a passive single-lead electrocardiogram acquisition module.

    PubMed

    Nayan, Nazrul Anuar; Risman, Nur Sabrina; Jaafar, Rosmina

    2016-07-27

    Among vital signs of acutely ill hospital patients, respiratory rate (RR) is a highly accurate predictor of health deterioration. This study proposes a system that consists of a passive and non-invasive single-lead electrocardiogram (ECG) acquisition module and an ECG-derived respiratory (EDR) algorithm in the working prototype of a mobile application. Before estimating RR that produces the EDR rate, ECG signals were evaluated based on the signal quality index (SQI). The SQI algorithm was validated quantitatively using the PhysioNet/Computing in Cardiology Challenge 2011 training data set. The RR extraction algorithm was validated by adopting 40 MIT PhysioNet Multiparameter Intelligent Monitoring in Intensive Care II data set. The estimated RR showed a mean absolute error (MAE) of 1.4 compared with the ``gold standard'' RR. The proposed system was used to record 20 ECGs of healthy subjects and obtained the estimated RR with MAE of 0.7 bpm. Results indicate that the proposed hardware and algorithm could replace the manual counting method, uncomfortable nasal airflow sensor, chest band, and impedance pneumotachography often used in hospitals. The system also takes advantage of the prevalence of smartphone usage and increase the monitoring frequency of the current ECG of patients with critical illnesses.

  12. Development of a wearable multi-frequency impedance cardiography device.

    PubMed

    Weyer, Sören; Menden, Tobias; Leicht, Lennart; Leonhardt, Steffen; Wartzek, Tobias

    2015-02-01

    Cardiovascular diseases as well as pulmonary oedema can be early diagnosed using vital signs and thoracic bio-impedance. By recording the electrocardiogram (ECG) and the impedance cardiogram (ICG), vital parameters are captured continuously. The aim of this study is the continuous monitoring of ECG and multi-frequency ICG by a mobile system. A mobile measuring system, based on 'low-power' ECG, ICG and an included radio transmission is described. Due to the high component integration, a board size of only 6.5 cm×5 cm could be realized. The measured data can be transmitted via Bluetooth and visualized on a portable monitor. By using energy-efficient hardware, the system can operate for up to 18 hs with a 3 V battery, continuously sending data via Bluetooth. Longer operating times can be realized by decreased transfer rates. The relative error of the impedance measurement was less than 1%. The ECG and ICG measurements allow an approximate calculation of the heart stroke volume. The ECG and the measured impedance showed a high correlation to commercial devices (r=0.83, p<0.05). In addition to commercial devices, the developed system allows a multi-frequency measurement of the thoracic impedance between 5-150 kHz.

  13. Deployment of an Advanced Electrocardiographic Analysis (A-ECG) to Detect Cardiovascular Risk in Career Firefighters

    NASA Technical Reports Server (NTRS)

    Dolezal, B. A.; Storer, T. W.; Abrazado, M.; Watne, R.; Schlegel, T. T.; Batalin, M.; Kaiser, W.; Smith, D. L.; Cooper, C. B.

    2011-01-01

    INTRODUCTION Sudden cardiac death is the leading cause of line of duty death among firefighters, accounting for approximately 45% of fatalities annually. Firefighters perform strenuous muscular work while wearing heavy, encapsulating personal protective equipment in high ambient temperatures, under chaotic and emotionally stressful conditions. These factors can precipitate sudden cardiac events like myocardial infarction, serious dysrhythmias, or cerebrovascular accidents in firefighters with underlying cardiovascular disease. Screening for cardiovascular risk factors is recommended but not always followed in this population. PHASER is a project charged with identifying and prioritizing risk factors in emergency responders. We have deployed an advanced ECG (A-ECG) system developed at NASA for improved sensitivity and specificity in the detection of cardiac risk. METHODS Forty-four professional firefighters were recruited to perform comprehensive baseline assessments including tests of aerobic performance and laboratory tests for fasting lipid profiles and glucose. Heart rate and conventional 12-lead ECG were obtained at rest and during incremental treadmill exercise testing (XT). In addition, a 5-min resting 12-lead A-ECG was obtained in a subset of firefighters (n=18) and transmitted over a secure networked system to a physician collaborator at NASA for advanced-ECG analysis. This A-ECG system has been proven, using myocardial perfusion and other imaging, to accurately identify a number of cardiac pathologies including coronary artery disease (CAD), left ventricular hypertrophy, hypertrophic cardiomyopathy, non-ischemic cardiomyopathy, and ischemic cardiomyopathy. RESULTS Subjects mean (SD) age was 43 (8) years, weight 91 (13) kg, and BMI of 28 (3) kg/square meter. Maximum oxygen uptake (VO2max) was 39 (9) ml/kg/min. This compares with the 45th %ile in healthy reference values and a recommended standard of 42 ml/kg/min for firefighters. The metabolic threshold (VO2Theta) above which lactate accumulates was 23 (8) ml/kg/min. The chronotropic index, a measure of cardiovascular strain during XT was 35 (8) /L compared with reference values for men of 40 /L. Total cholesterol, LDL-C and HDL-C were 202 (34),126 (29), and 55 (15) mg/dl, respectively. Fifty-one percent of subjects had .3 cardiovascular risk factors, 2 subjects had resting hypertension (BP.140/90), and 23 had pre-hypertension (.120/80 but <140/90). Seven had exaggerated exercise induced hypertension but only one had ST depression on XT ECG, at least one positive A-ECG score for CAD, and documented CAD based on cardiology referral. While all other subjects, including those with fewer risk factors, higher aerobic fitness, and normal exercise ECGs, were classified as healthy by A-ECG, there was no trend for association between risk factors and any of 20 A-ECG parameters in the grouped data. CONCLUSIONS A-ECG screening correctly identified the individual with CAD although there was no trend for A-ECG parameters to distinguish those with elevated BP or multiple risk factors but normal XT ECG. We have demonstrated that a new technology, advanced-ECG, can be introduced for remote firefighter risk assessment. This simple, time and cost-effective approach to risk identification that can be acquired remotely and transmitted securely can detect individuals potentially at risk for line-of-duty death. Additional research is needed to further document its value.

  14. Diagnostic performance of coronary computed tomography angiography versus exercise electrocardiography for coronary artery disease: a systematic review and meta-analysis.

    PubMed

    Yin, Xinxin; Wang, Jiali; Zheng, Wen; Ma, Jingjing; Hao, Panpan; Chen, Yuguo

    2016-07-01

    Both coronary computed tomography angiography (CCTA) and exercise electrocardiography (ExECG) are non-invasive testing methods for the evaluation of coronary artery disease (CAD). However, there was controversy on the diagnostic performance of these methods due to the limited data in each single study. Therefore, we performed a meta-analysis to address these issues. We searched PubMed and Embase databases up to May 22, 2015. Two authors identified eligible studies, extracted data and accessed quality. Pooled estimation of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), summary receiver-operating characteristic curve (SROC) and the area under curve (AUC) of CCTA and ExECG for the diagnosis of CAD were calculated using Stata, Meta-Disc and Review Manager statistical software. Seven articles were included. Pooled sensitivity of CCTA and ExECG were 0.98 [95% confidence intervals (CIs): 0.95-0.99] and 0.66 (95% CIs: 0.59-0.72); pooled specificity of CCTA and ExECG were 0.84 (95% CIs: 0.81-0.87) and 0.75 (95% CIs: 0.71-0.79); pooled DOR of CCTA and ExECG were 110.24 (95% CIs: 35.07-346.55) and 6.28 (95% CIs: 2.06-19.13); and AUC of CCTA and ExECG were 0.9950±0.0046 and 0.7727±0.0638, respectively. There is no heterogeneity caused by threshold effect in CCTA or ExECG analysis. The Deeks' test showed no potential publication bias (P=0.17). CCTA has better diagnostic performance than ExECG in the evaluation of CAD, which can provide a better solution for the clinical problem of the diagnosis for CAD.

  15. Novel technical solutions for wireless ECG transmission & analysis in the age of the internet cloud.

    PubMed

    Al-Zaiti, Salah S; Shusterman, Vladimir; Carey, Mary G

    2013-01-01

    Current guidelines recommend early reperfusion therapy for ST-elevation myocardial infarction (STEMI) within 90 min of first medical encounter. Telecardiology entails the use of advanced communication technologies to transmit the prehospital 12-lead electrocardiogram (ECG) to offsite cardiologists for early triage to the cath lab; which has been shown to dramatically reduce door-to-balloon time and total mortality. However, hospitals often find adopting ECG transmission technologies very challenging. The current review identifies seven major technical challenges of prehospital ECG transmission, including: paramedics inconvenience and transport delay; signal noise and interpretation errors; equipment malfunction and transmission failure; reliability of mobile phone networks; lack of compliance with the standards of digital ECG formats; poor integration with electronic medical records; and costly hardware and software pre-requisite installation. Current and potential solutions to address each of these technical challenges are discussed in details and include: automated ECG transmission protocols; annotatable waveform-based ECGs; optimal routing solutions; and the use of cloud computing systems rather than vendor-specific processing stations. Nevertheless, strategies to monitor transmission effectiveness and patient outcomes are essential to sustain initial gains of implementing ECG transmission technologies. © 2013.

  16. A Precise Drunk Driving Detection Using Weighted Kernel Based on Electrocardiogram.

    PubMed

    Wu, Chung Kit; Tsang, Kim Fung; Chi, Hao Ran; Hung, Faan Hei

    2016-05-09

    Globally, 1.2 million people die and 50 million people are injured annually due to traffic accidents. These traffic accidents cost $500 billion dollars. Drunk drivers are found in 40% of the traffic crashes. Existing drunk driving detection (DDD) systems do not provide accurate detection and pre-warning concurrently. Electrocardiogram (ECG) is a proven biosignal that accurately and simultaneously reflects human's biological status. In this letter, a classifier for DDD based on ECG is investigated in an attempt to reduce traffic accidents caused by drunk drivers. At this point, it appears that there is no known research or literature found on ECG classifier for DDD. To identify drunk syndromes, the ECG signals from drunk drivers are studied and analyzed. As such, a precise ECG-based DDD (ECG-DDD) using a weighted kernel is developed. From the measurements, 10 key features of ECG signals were identified. To incorporate the important features, the feature vectors are weighted in the customization of kernel functions. Four commonly adopted kernel functions are studied. Results reveal that weighted feature vectors improve the accuracy by 11% compared to the computation using the prime kernel. Evaluation shows that ECG-DDD improved the accuracy by 8% to 18% compared to prevailing methods.

  17. An Advanced Bio-Inspired PhotoPlethysmoGraphy (PPG) and ECG Pattern Recognition System for Medical Assessment

    PubMed Central

    Rundo, Francesco; Ortis, Alessandro

    2018-01-01

    Physiological signals are widely used to perform medical assessment for monitoring an extensive range of pathologies, usually related to cardio-vascular diseases. Among these, both PhotoPlethysmoGraphy (PPG) and Electrocardiography (ECG) signals are those more employed. PPG signals are an emerging non-invasive measurement technique used to study blood volume pulsations through the detection and analysis of the back-scattered optical radiation coming from the skin. ECG is the process of recording the electrical activity of the heart over a period of time using electrodes placed on the skin. In the present paper we propose a physiological ECG/PPG “combo” pipeline using an innovative bio-inspired nonlinear system based on a reaction-diffusion mathematical model, implemented by means of the Cellular Neural Network (CNN) methodology, to filter PPG signal by assigning a recognition score to the waveforms in the time series. The resulting “clean” PPG signal exempts from distortion and artifacts is used to validate for diagnostic purpose an EGC signal simultaneously detected for a same patient. The multisite combo PPG-ECG system proposed in this work overpasses the limitations of the state of the art in this field providing a reliable system for assessing the above-mentioned physiological parameters and their monitoring over time for robust medical assessment. The proposed system has been validated and the results confirmed the robustness of the proposed approach. PMID:29385774

  18. An Advanced Bio-Inspired PhotoPlethysmoGraphy (PPG) and ECG Pattern Recognition System for Medical Assessment.

    PubMed

    Rundo, Francesco; Conoci, Sabrina; Ortis, Alessandro; Battiato, Sebastiano

    2018-01-30

    Physiological signals are widely used to perform medical assessment for monitoring an extensive range of pathologies, usually related to cardio-vascular diseases. Among these, both PhotoPlethysmoGraphy (PPG) and Electrocardiography (ECG) signals are those more employed. PPG signals are an emerging non-invasive measurement technique used to study blood volume pulsations through the detection and analysis of the back-scattered optical radiation coming from the skin. ECG is the process of recording the electrical activity of the heart over a period of time using electrodes placed on the skin. In the present paper we propose a physiological ECG/PPG "combo" pipeline using an innovative bio-inspired nonlinear system based on a reaction-diffusion mathematical model, implemented by means of the Cellular Neural Network (CNN) methodology, to filter PPG signal by assigning a recognition score to the waveforms in the time series. The resulting "clean" PPG signal exempts from distortion and artifacts is used to validate for diagnostic purpose an EGC signal simultaneously detected for a same patient. The multisite combo PPG-ECG system proposed in this work overpasses the limitations of the state of the art in this field providing a reliable system for assessing the above-mentioned physiological parameters and their monitoring over time for robust medical assessment. The proposed system has been validated and the results confirmed the robustness of the proposed approach.

  19. New system for digital to analog transformation and reconstruction of 12-lead ECGs.

    PubMed

    Kothadia, Roshni; Kulecz, Walter B; Kofman, Igor S; Black, Adam J; Grier, James W; Schlegel, Todd T

    2013-01-01

    We describe initial validation of a new system for digital to analog conversion (DAC) and reconstruction of 12-lead ECGs. The system utilizes an open and optimized software format with a commensurately optimized DAC hardware configuration to accurately reproduce, from digital files, the original analog electrocardiographic signals of previously instrumented patients. By doing so, the system also ultimately allows for transmission of data collected on one manufacturer's 12-lead ECG hardware/software into that of any other. To initially validate the system, we compared original and post-DAC re-digitized 12-lead ECG data files (∼5-minutes long) in two types of validation studies in 10 patients. The first type quantitatively compared the total waveform voltage differences between the original and re-digitized data while the second type qualitatively compared the automated electrocardiographic diagnostic statements generated by the original versus re-digitized data. The grand-averaged difference in root mean squared voltage between the original and re-digitized data was 20.8 µV per channel when re-digitization involved the same manufacturer's analog to digital converter (ADC) as the original digitization, and 28.4 µV per channel when it involved a different manufacturer's ADC. Automated diagnostic statements generated by the original versus reconstructed data did not differ when using the diagnostic algorithm from the same manufacturer on whose device the original data were collected, and differed only slightly for just 1 of 10 patients when using a third-party diagnostic algorithm throughout. Original analog 12-lead ECG signals can be reconstructed from digital data files with accuracy sufficient for clinical use. Such reconstructions can readily enable automated second opinions for difficult-to-interpret 12-lead ECGs, either locally or remotely through the use of dedicated or cloud-based servers.

  20. Does cardiac catheterization laboratory activation by electrocardiography machine auto-interpretation reduce door-to-balloon time?

    PubMed

    Min, Mun Ki; Ryu, Ji Ho; Kim, Yong In; Park, Maeng Real; Park, Yong Myeon; Park, Sung Wook; Yeom, Seok Ran; Han, Sang Kyoon; Kim, Yang Weon

    2014-11-01

    In an attempt to begin ST-segment elevation myocardial infarction (STEMI) treatment more quickly (referred to as door-to-balloon [DTB] time) by minimizing preventable delays in electrocardiogram (ECG) interpretation, cardiac catheterization laboratory (CCL) activation was changed from activation by the emergency physician (code heart I) to activation by a single page if the ECG is interpreted as STEMI by the ECG machine (ECG machine auto-interpretation) (code heart II). We sought to determine the impact of ECG machine auto-interpretation on CCL activation. The study period was from June 2010 to May 2012 (from June to November 2011, code heart I; from December 2011 to May 2012, code heart II). All patients aged 18 years or older who were diagnosed with STEMI were evaluated for enrollment. Patients who experienced the code heart system were also included. Door-to-balloon time before and after code heart system were compared with a retrospective chart review. In addition, to determine the appropriateness of the activation, we compared coronary angiography performance rate and percentage of STEMI between code heart I and II. After the code heart system, the mean DTB time was significantly decreased (before, 96.51 ± 65.60 minutes; after, 65.40 ± 26.40 minutes; P = .043). The STEMI diagnosis and the coronary angiography performance rates were significantly lower in the code heart II group than in the code heart I group without difference in DTB time. Cardiac catheterization laboratory activation by ECG machine auto-interpretation does not reduce DTB time and often unnecessarily activates the code heart system compared with emergency physician-initiated activation. This system therefore decreases the appropriateness of CCL activation. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Toward personal eHealth in cardiology. Results from the EPI-MEDICS telemedicine project.

    PubMed

    Rubel, Paul; Fayn, Jocelyne; Nollo, Giandomenico; Assanelli, Deodato; Li, Bo; Restier, Lioara; Adami, Stefano; Arod, Sébastien; Atoui, Hussein; Ohlsson, Mattias; Simon-Chautemps, Lucas; Télisson, David; Malossi, Cesare; Ziliani, Gian-Luca; Galassi, Alfredo; Edenbrandt, Lars; Chevalier, Philippe

    2005-10-01

    Despite many attempts to improve the management of acute myocardial infarction, only small trends to shorter time intervals before treatment have been reported. The self-care solution developed by the European EPI-MEDICS project (2001-2004) is a novel, very affordable, easy-to-use, portable, and intelligent Personal ECG Monitor (PEM) for the early detection of cardiac ischemia and arrhythmia that is able to record a professional-quality, 3-lead electrocardiogram (ECG) based on leads I, II, and V2; derive the missing leads of the standard 12-lead ECG (thanks to either a generic or a patient-specific transform), compare each ECG with a reference ECG by means of advanced neural network-based decision-making methods taking into account the serial ECG measurements and the patient risk factors and clinical data; and generate different levels of alarms and forward the alarm messages with the recorded ECGs and the patient's Personal electronic Health Record (PHR) to the relevant health care providers by means of a standard Bluetooth-enabled, GSM/GPRS-compatible mobile phone. The ECG records are SCP-ECG encoded and stored with the PHR on a secure personal SD Card embedded in the PEM device. The alarm messages and the PHR are XML encoded. Major alarm messages are automatically transmitted to the nearest emergency call center. Medium or minor alarms are sent on demand to a central PEM Alarm Web Server. Health professionals are informed by a Short Message Service. The PEM embeds itself a Web server to facilitate the reviewing and/or update of the PHR during a routine visit at the office of the general physician or cardiologist. Eighty PEM prototypes have been finalized and tested for several weeks on 697 citizens/patients in different clinical and self-care situations involving end users (188 patients), general physicians (10), and cardiologists (9). The clinical evaluation indicates that the EPI-MEDICS concept may save lives and is very valuable for prehospitalization triage.

  2. Relation of electrocardiographic left ventricular hypertrophy to blood pressure, body mass index, serum lipids and blood sugar levels in adult Nigerians.

    PubMed

    Opadijo, O G; Omotoso, A B O; Akande, A A

    2003-12-01

    Left ventricular hypertrophy (LVH) is considered an independent risk factor even in the absence of systemic hypertension. Electrocardiographic (ECG) LVH with repolarisation changes has been found in some countries to carry more coronary risk than LVH alone. How far this observation is true among adult Nigerians is not known. We therefore decided to study adult Nigerians with ECG-LVH with or without ST-T waves changes and compare them with normal age matched controls (without ECG-LVH) in relation with established modifiable risk factors such as systemic hypertension (BP), body mass index (BMI), fasting blood sugar (FBS) and serum lipids such as total cholesterol (Tc), low density lipoprotein cholesterol (LDL-C), high density lipoprotein cholesterol (HDL-C) and triglyceride (TG). Adult Nigerians who were consecutively referred to the ECG laboratory were randomly recruited. Three hundred patients were studied. Their blood pressures (BP) as well as body mass indices were recorded after recording their resting 12 read ECG using portable Seward 9953 ECG machine. Their waist-hip ratio (WHR) was also recorded. Blood samples were taken to determine their fasting blood sugar and serum lipids. Their ECG tracings were read by the cardiologists involved in the study while the blood samples were analysed by the chemical pathologist also involved in the study. At the end of the ECG reading, the patients were divided into 3 groups according to whether there was no ECG-LVH (control group A), ECG-LVH alone (group B), and ECG-LVH with ST-T waves changes (group C). One hundred and fifty (50%) patients belonged to group A, 100 (33.3%) patients to group B and 50 (16.7%) group C. Group B patients were found to have higher modifiable risk factors in form of systemic BP. Tc, LDL-C, and WHR compared to group A. However, the group C patients had increased load of these coronary risk factors in terms of BP elevation, higher BMI, FBS, and scrum cholesterol compared to group B. In addition, more female patients were involved in group C. The mean age of group C patients compared to group B was also significantly higher (P<0.001) even though no significant age difference was noted between group C and group A patients. It is concluded that Nigerians with ECG-LVH with ST-T waves changes have increased risk of cardiovascular risk factors compared to normal group A patients and even patients with EGC-LVH (group B) alone. Hence, they represent subset of patients to be aggressively followed up with multiple risk factors intervention.

  3. Implementation and assessment of an animal management system for small-animal micro-CT / micro-SPECT imaging

    NASA Astrophysics Data System (ADS)

    Holdsworth, David W.; Detombe, Sarah A.; Chiodo, Chris; Fricke, Stanley T.; Drangova, Maria

    2011-03-01

    Advances in laboratory imaging systems for CT, SPECT, MRI, and PET facilitate routine micro-imaging during pre-clinical investigations. Challenges still arise when dealing with immune-compromised animals, biohazardous agents, and multi-modality imaging. These challenges can be overcome with an appropriate animal management system (AMS), with the capability for supporting and monitoring a rat or mouse during micro-imaging. We report the implementation and assessment of a new AMS system for mice (PRA-3000 / AHS-2750, ASI Instruments, Warren MI), designed to be compatible with a commercial micro-CT / micro-SPECT imaging system (eXplore speCZT, GE Healthcare, London ON). The AMS was assessed under the following criteria: 1) compatibility with the imaging system (i.e. artifact generation, geometric dimensions); 2) compatibility with live animals (i.e. positioning, temperature regulation, anesthetic supply); 3) monitoring capabilities (i.e. rectal temperature, respiratory and cardiac monitoring); 4) stability of co-registration; and 5) containment. Micro-CT scans performed using a standardized live-animal protocol (90 kVp, 40 mA, 900 views, 16 ms per view) exhibited low noise (+/-19 HU) and acceptable artifact from high-density components within the AMS (e.g. ECG pad contacts). Live mice were imaged repeatedly (with removal and replacement of the AMS) and spatial registration was found to be stable to within +/-0.07 mm. All animals tolerated enclosure within the AMS for extended periods (i.e. > one hour) without distress, based on continuous recordings of rectal temperature, ECG waveform and respiratory rate. A sealed AMS system extends the capability of a conventional micro-imaging system to include immune-compromised and biosafety level 2 mouse-imaging protocols.

  4. Biometric and Emotion Identification: An ECG Compression Based Method.

    PubMed

    Brás, Susana; Ferreira, Jacqueline H T; Soares, Sandra C; Pinho, Armando J

    2018-01-01

    We present an innovative and robust solution to both biometric and emotion identification using the electrocardiogram (ECG). The ECG represents the electrical signal that comes from the contraction of the heart muscles, indirectly representing the flow of blood inside the heart, it is known to convey a key that allows biometric identification. Moreover, due to its relationship with the nervous system, it also varies as a function of the emotional state. The use of information-theoretic data models, associated with data compression algorithms, allowed to effectively compare ECG records and infer the person identity, as well as emotional state at the time of data collection. The proposed method does not require ECG wave delineation or alignment, which reduces preprocessing error. The method is divided into three steps: (1) conversion of the real-valued ECG record into a symbolic time-series, using a quantization process; (2) conditional compression of the symbolic representation of the ECG, using the symbolic ECG records stored in the database as reference; (3) identification of the ECG record class, using a 1-NN (nearest neighbor) classifier. We obtained over 98% of accuracy in biometric identification, whereas in emotion recognition we attained over 90%. Therefore, the method adequately identify the person, and his/her emotion. Also, the proposed method is flexible and may be adapted to different problems, by the alteration of the templates for training the model.

  5. Biometric and Emotion Identification: An ECG Compression Based Method

    PubMed Central

    Brás, Susana; Ferreira, Jacqueline H. T.; Soares, Sandra C.; Pinho, Armando J.

    2018-01-01

    We present an innovative and robust solution to both biometric and emotion identification using the electrocardiogram (ECG). The ECG represents the electrical signal that comes from the contraction of the heart muscles, indirectly representing the flow of blood inside the heart, it is known to convey a key that allows biometric identification. Moreover, due to its relationship with the nervous system, it also varies as a function of the emotional state. The use of information-theoretic data models, associated with data compression algorithms, allowed to effectively compare ECG records and infer the person identity, as well as emotional state at the time of data collection. The proposed method does not require ECG wave delineation or alignment, which reduces preprocessing error. The method is divided into three steps: (1) conversion of the real-valued ECG record into a symbolic time-series, using a quantization process; (2) conditional compression of the symbolic representation of the ECG, using the symbolic ECG records stored in the database as reference; (3) identification of the ECG record class, using a 1-NN (nearest neighbor) classifier. We obtained over 98% of accuracy in biometric identification, whereas in emotion recognition we attained over 90%. Therefore, the method adequately identify the person, and his/her emotion. Also, the proposed method is flexible and may be adapted to different problems, by the alteration of the templates for training the model. PMID:29670564

  6. [Synchronous playing and acquiring of heart sounds and electrocardiogram based on labVIEW].

    PubMed

    Dan, Chunmei; He, Wei; Zhou, Jing; Que, Xiaosheng

    2008-12-01

    In this paper is described a comprehensive system, which can acquire heart sounds and electrocardiogram (ECG) in parallel, synchronize the display; and play of heart sound and make auscultation and check phonocardiogram to tie in. The hardware system with C8051F340 as the core acquires the heart sound and ECG synchronously, and then sends them to indicators, respectively. Heart sounds are displayed and played simultaneously by controlling the moment of writing to indicator and sound output device. In clinical testing, heart sounds can be successfully located with ECG and real-time played.

  7. Detection of Acute Myocardial Infarction in a Pig Model Using the SAN-Atrial-AVN-His (SAAH) Electrocardiogram (ECG), Model PHS-A10, an Automated and Integrated Signals Recognition System

    PubMed Central

    Zhao, Wenjiao; Lu, Guihua; Liu, Li; Sun, Zhishan; Wu, Mingxin; Yi, Wenyan; Chen, Haiyan; Li, Yanhui

    2018-01-01

    Background The aim of this study was to compare the use of the standard 12-lead electrocardiogram (ECG) with the SAN-Atrial-AVN-His (SAAH) ECG (Model PHS-A10), a new automated and integrated signals recognition system that detects micro-waveforms within the P, QRS, and T-wave, in a pig model of acute myocardial infarction (MI). Material/Methods Six medium-sized domestic Chinese pigs underwent general anesthesia, and an angioplasty balloon was placed and dilated for 120 minutes in the first diagonal coronary artery arising from the left anterior descending (LAD) coronary artery. A standard ECG and a SAAH ECG (Model PHS-A10) were used to evaluate: 1) the number of wavelets in ST-T segment in lead V5; 2) the duration of the repolarization initial (Ri), or duration of the wavelets starting from the J-point to the endpoint of the wavelets in the ST interval; 3) the duration of the repolarization terminal (Rt), of the wavelets, starting from the endpoint of the wavelets in the ST interval to the cross-point of the T-wave and baseline; 4) the ratio Ri: Rt. Results Following coronary artery occlusion, duration of Ri and Ri/Rt increased, and Rt decreased, which was detected by the SAAH ECG (Model PHS-A10) within 12 seconds, compared with standard ECG that detected ST segment depression at 24 seconds following coronary artery occlusion. Conclusions The findings from this preliminary study in a pig model of acute MI support the need for clinical studies to evaluate the SAAH ECG (Model PHS-A10) for the early detection of acute MI. PMID:29502127

  8. Detection of Acute Myocardial Infarction in a Pig Model Using the SAN-Atrial-AVN-His (SAAH) Electrocardiogram (ECG), Model PHS-A10, an Automated and Integrated Signals Recognition System.

    PubMed

    Zhao, Wenjiao; Lu, Guihua; Liu, Li; Sun, Zhishan; Wu, Mingxin; Yi, Wenyan; Chen, Haiyan; Li, Yanhui; Tang, Lilong; Zeng, Jianping

    2018-03-04

    BACKGROUND The aim of this study was to compare the use of the standard 12-lead electrocardiogram (ECG) with the SAN-Atrial-AVN-His (SAAH) ECG (Model PHS-A10), a new automated and integrated signals recognition system that detects micro-waveforms within the P, QRS, and T-wave, in a pig model of acute myocardial infarction (MI). MATERIAL AND METHODS Six medium-sized domestic Chinese pigs underwent general anesthesia, and an angioplasty balloon was placed and dilated for 120 minutes in the first diagonal coronary artery arising from the left anterior descending (LAD) coronary artery. A standard ECG and a SAAH ECG (Model PHS-A10) were used to evaluate: 1) the number of wavelets in ST-T segment in lead V5; 2) the duration of the repolarization initial (Ri), or duration of the wavelets starting from the J-point to the endpoint of the wavelets in the ST interval; 3) the duration of the repolarization terminal (Rt), of the wavelets, starting from the endpoint of the wavelets in the ST interval to the cross-point of the T-wave and baseline; 4) the ratio Ri: Rt. RESULTS Following coronary artery occlusion, duration of Ri and Ri/Rt increased, and Rt decreased, which was detected by the SAAH ECG (Model PHS-A10) within 12 seconds, compared with standard ECG that detected ST segment depression at 24 seconds following coronary artery occlusion. CONCLUSIONS The findings from this preliminary study in a pig model of acute MI support the need for clinical studies to evaluate the SAAH ECG (Model PHS-A10) for the early detection of acute MI.

  9. An Analysis for Capital Expenditure Decisions at a Naval Regional Medical Center.

    DTIC Science & Technology

    1981-12-01

    Service Equipment Review Committee 1. Portable defibrilator Computed tomographic scanner and cardioscope 2. ECG cart Automated blood cell counter 3. Gas...system sterilizer Gas system sterilizer 4. Automated blood cell Portable defibrilator and counter cardioscope 5. Computed tomographic ECG cart scanner...dictating and automated typing) systems. e. Filing equipment f. Automatic data processing equipment including data communications equipment. g

  10. Induction of Inflammation In Vivo by Electrocardiogram Sensor Operation Using Wireless Power Transmission.

    PubMed

    Heo, Jin-Chul; Kim, Beomjoon; Kim, Yoon-Nyun; Kim, Dae-Kwang; Lee, Jong-Ha

    2017-12-14

    Prolonged monitoring by cardiac electrocardiogram (ECG) sensors is useful for patients with emergency heart conditions. However, implant monitoring systems are limited by lack of tissue biocompatibility. Here, we developed an implantable ECG sensor for real-time monitoring of ventricular fibrillation and evaluated its biocompatibility using an animal model. The implantable sensor comprised transplant sensors with two electrodes, a wireless power transmission system, and a monitoring system. The sensor was inserted into the subcutaneous tissue of the abdominal area and operated for 1 h/day for 5 days using a wireless power system. Importantly, the sensor was encapsulated by subcutaneous tissue and induced angiogenesis, inflammation, and phagocytosis. In addition, we observed that the levels of inflammation-related markers increased with wireless-powered transmission via the ECG sensor; in particular, levels of the Th-1 cytokine interleukin-12 were significantly increased. The results showed that induced tissue damage was associated with the use of wireless-powered sensors. We also investigated research strategies for the prevention of adverse effects caused by lack of tissue biocompatibility of a wireless-powered ECG monitoring system and provided information on the clinical applications of inflammatory reactions in implant treatment using the wireless-powered transmission system.

  11. Induction of Inflammation In Vivo by Electrocardiogram Sensor Operation Using Wireless Power Transmission

    PubMed Central

    Heo, Jin-Chul; Kim, Beomjoon; Kim, Yoon-Nyun; Kim, Dae-Kwang; Lee, Jong-Ha

    2017-01-01

    Prolonged monitoring by cardiac electrocardiogram (ECG) sensors is useful for patients with emergency heart conditions. However, implant monitoring systems are limited by lack of tissue biocompatibility. Here, we developed an implantable ECG sensor for real-time monitoring of ventricular fibrillation and evaluated its biocompatibility using an animal model. The implantable sensor comprised transplant sensors with two electrodes, a wireless power transmission system, and a monitoring system. The sensor was inserted into the subcutaneous tissue of the abdominal area and operated for 1 h/day for 5 days using a wireless power system. Importantly, the sensor was encapsulated by subcutaneous tissue and induced angiogenesis, inflammation, and phagocytosis. In addition, we observed that the levels of inflammation-related markers increased with wireless-powered transmission via the ECG sensor; in particular, levels of the Th-1 cytokine interleukin-12 were significantly increased. The results showed that induced tissue damage was associated with the use of wireless-powered sensors. We also investigated research strategies for the prevention of adverse effects caused by lack of tissue biocompatibility of a wireless-powered ECG monitoring system and provided information on the clinical applications of inflammatory reactions in implant treatment using the wireless-powered transmission system. PMID:29240666

  12. Trigger learning and ECG parameter customization for remote cardiac clinical care information system.

    PubMed

    Bashir, Mohamed Ezzeldin A; Lee, Dong Gyu; Li, Meijing; Bae, Jang-Whan; Shon, Ho Sun; Cho, Myung Chan; Ryu, Keun Ho

    2012-07-01

    Coronary heart disease is being identified as the largest single cause of death along the world. The aim of a cardiac clinical information system is to achieve the best possible diagnosis of cardiac arrhythmias by electronic data processing. Cardiac information system that is designed to offer remote monitoring of patient who needed continues follow up is demanding. However, intra- and interpatient electrocardiogram (ECG) morphological descriptors are varying through the time as well as the computational limits pose significant challenges for practical implementations. The former requires that the classification model be adjusted continuously, and the latter requires a reduction in the number and types of ECG features, and thus, the computational burden, necessary to classify different arrhythmias. We propose the use of adaptive learning to automatically train the classifier on up-to-date ECG data, and employ adaptive feature selection to define unique feature subsets pertinent to different types of arrhythmia. Experimental results show that this hybrid technique outperforms conventional approaches and is, therefore, a promising new intelligent diagnostic tool.

  13. Treatment with eCG decreases the vascular density and increases the glandular density of the bovine uterus.

    PubMed

    Mona e Pinto, J; Pavanelo, V; Alves de Fátima, L; Medeiros de Carvalho Sousa, L M; Pacheco Mendes, G; Machado Ferreira, R; Ayres, H; Sampaio Baruselli, P; Palma Rennó, F; de Carvallo Papa, P

    2014-06-01

    The uterus plays an essential role in mammalian reproduction and is a target of several hormonal protocols used to improve fertility in cattle. Many studies highlighted the importance of eCG treatment following fixed-time artificial insemination in improving follicular growth, ovulation and pregnancy rates in cattle. Moreover, eCG has been implicated in angiogenesis, leading to important changes in uterine blood flow and vascularisation. However, there is still a lack of information regarding the specific alterations induced by eCG upon glandular and vascular characteristics of bovine uterus. To investigate the influence of eCG on: uterine thickness and area; uterine artery diameter and area; uterine vascular and gland density; and the expression of the VEGFA-system, the uteri of crossbred beef cows were collected. All cows were submitted to follicular wave emergence synchronization. On day four of protocol, cows submitted to superovulation (n = 6) received 2000 IU eCG, on day eight, after expected follicular deviation, cows submitted to stimulatory treatment (n = 5) received 400 IU eCG. Control cows (n = 5) did not receive eCG. On day five po cows were subjected to ultrassonographic evaluation and slaughtered for uterine tissue sampling on day six po. Uterine vessels and glands were quantified by the counting point stereological method. The VEGFA-system was localized in different cellular types, showing no qualitative or quantitative differences in the site of expression or the intensity of the positive signal among the groups. Vascular density was decreased in the endometrium of stimulated and myometrium of superovulated cows compared with the control ones, which showed higher vascular density in the myometrium and endometrium of the ipsilateral uterine horn. The uterine gland density was higher in superovulated compared with stimulated and control cows. Thus, we can infer that stimulatory or superovulatory treatments with eCG influence the vascular density in the endometrium and myometrium in cattle. © 2014 Blackwell Verlag GmbH.

  14. Concept Design for a 1-Lead Wearable/Implantable ECG Front-End: Power Management

    PubMed Central

    George, Libin; Gargiulo, Gaetano Dario; Lehmann, Torsten; Hamilton, Tara Julia

    2015-01-01

    Power supply quality and stability are critical for wearable and implantable biomedical applications. For this reason we have designed a reconfigurable switched-capacitor DC-DC converter that, aside from having an extremely small footprint (with an active on-chip area of only 0.04 mm2), uses a novel output voltage control method based upon a combination of adaptive gain and discrete frequency scaling control schemes. This novel DC-DC converter achieves a measured output voltage range of 1.0 to 2.2 V with power delivery up to 7.5 mW with 75% efficiency. In this paper, we present the use of this converter as a power supply for a concept design of a wearable (15 mm × 15 mm) 1-lead ECG front-end sensor device that simultaneously harvests power and communicates with external receivers when exposed to a suitable RF field. Due to voltage range limitations of the fabrication process of the current prototype chip, we focus our analysis solely on the power supply of the ECG front-end whose design is also detailed in this paper. Measurement results show not just that the power supplied is regulated, clean and does not infringe upon the ECG bandwidth, but that there is negligible difference between signals acquired using standard linear power-supplies and when the power is regulated by our power management chip. PMID:26610497

  15. Concept Design for a 1-Lead Wearable/Implantable ECG Front-End: Power Management.

    PubMed

    George, Libin; Gargiulo, Gaetano Dario; Lehmann, Torsten; Hamilton, Tara Julia

    2015-11-19

    Power supply quality and stability are critical for wearable and implantable biomedical applications. For this reason we have designed a reconfigurable switched-capacitor DC-DC converter that, aside from having an extremely small footprint (with an active on-chip area of only 0.04 mm²), uses a novel output voltage control method based upon a combination of adaptive gain and discrete frequency scaling control schemes. This novel DC-DC converter achieves a measured output voltage range of 1.0 to 2.2 V with power delivery up to 7.5 mW with 75% efficiency. In this paper, we present the use of this converter as a power supply for a concept design of a wearable (15 mm × 15 mm) 1-lead ECG front-end sensor device that simultaneously harvests power and communicates with external receivers when exposed to a suitable RF field. Due to voltage range limitations of the fabrication process of the current prototype chip, we focus our analysis solely on the power supply of the ECG front-end whose design is also detailed in this paper. Measurement results show not just that the power supplied is regulated, clean and does not infringe upon the ECG bandwidth, but that there is negligible difference between signals acquired using standard linear power-supplies and when the power is regulated by our power management chip.

  16. [Current status of the development of wireless sensors for medical applications].

    PubMed

    Moor, C; Braecklein, M; Jörns, N

    2005-01-01

    Wireless near-field transmission has been a challenge for scientists developing medical sensors for a long time. Here, instruments which measure a patient's ECG, oxygen saturation, blood pressure, peak flow, weight, blood glucose etc. are to be equipped with suitable transmission technology. Application scenarios for these sensors can be found in all medical areas where cable connections are irritating for the doctor, patient and other care personnel. This problem is especially common in sport medicine, sleep medicine, emergency medicine and intensive care. Based on its beneficial properties with regard to power consumption, range, data security and network capability, the worldwide standard radio technology Bluetooth was selected to transmit measurements. Since digital data is sent to a receiving station via Bluetooth, the measurement pre-processing now takes place in the patient sensor itself, instead of being processed by the monitor. In this article, a Bluetooth ECG, Bluetooth pulse oximeter, Bluetooth peak flow meter and Bluetooth event recorder will be introduced. On the one hand, systems can be realized with these devices, which allow patients to be monitored online (ECG, pulse oximeter). These devices can also be integrated in disease management programs (peak flow meter) and can be used to monitor high-risk patients in their home environment (event recorder).

  17. Nonintrusive biosignal measurement system in a vehicle.

    PubMed

    Lee, Haet Bit; Choi, Jong Min; Kim, Jung Soo; Kim, Yun Seong; Baek, Hyun Jae; Ryu, Myung Suk; Sohn, Ryang Hee; Park, Kwang Suk

    2007-01-01

    Measurement of driver's state is important in both daily healthcare and prevention of car accidents. Existing measurement methods, however, are too complex and uncomfortable to measure for everyday. A nonintrusive biosignal monitoring system is demanded for increasing the accessibility. In this paper, we proposed a nonintrusive measurement system integrated in a vehicle for recording electrocardiographic (ECG) signals and tested the performance of the system. The system consists of dry electrodes attached to the steering wheel and a wireless communication module using a Bluetooth device. ECG signals measured by our system were compared with those by a conventional system employing wet electrodes during real city road driving. Various parameters used for HRV analysis in time and frequency domain showed no significant differences between the two simultaneously measured ECG signals. The result implies the possibility that developed system could have a potential to monitor health information in a vehicle instead of commercial equipments.

  18. [Risk management of QT-prolonging drugs by community pharmacists using a mobile electrocardiograph].

    PubMed

    Shinozaki, Kohki

    2010-11-01

    Prolongation of the QT interval is associated with a high risk of serious arrhythmia, i.e., torsades de pointes (TdP). However, in many cases, the QT-prolonging drug(s) is prescribed without performing a thorough check-up of the patient's condition, especially an electrocardiogram. In addition to patient interview, we used an electrocardiogram obtained with a mobile electrocardiograph (RMH-ECG) in a community pharmacy in order to improve the risk management for QT-prolonging drugs. A comparison of the results obtained using RMH-ECG (modified I) and 12-lead ECG (I) revealed that both corrected QT (QTc) values were almost identical, and the correlation coefficient was 0.96. In one month, 5 of 948 patients who visited our pharmacy and continuously took QT-prolonging drugs had additional risk factors for TdP (advanced age, female, and drug-drug interaction). We monitored the QT interval of one of these patients. She had received erythromycin for 19 months along with other drugs metabolized by a P450 (CYP3A4); benidipine and prednisolone (for over 2 years), and tacrolimus (for 13 weeks). Three RMH-ECG tests at every 2 weeks revealed that QTcs were normal (0.43-0.45 s); therefore, we dispensed drugs without any change in the prescription. Approximately 1 in 1200 individuals has a prolonged QT interval without any subjective symptoms, and the time window of drug-induced TdP is considered to be from several hours to months after taking these drugs. Therefore, we think that an ECG test should be performed in community pharmacies before dispensing QT-prolonging drugs and that the QT interval should be monitored.

  19. Derivation of respiration rate from ambulatory ECG and PPG using Ensemble Empirical Mode Decomposition: Comparison and fusion.

    PubMed

    Orphanidou, Christina

    2017-02-01

    A new method for extracting the respiratory rate from ECG and PPG obtained via wearable sensors is presented. The proposed technique employs Ensemble Empirical Mode Decomposition in order to identify the respiration "mode" from the noise-corrupted Heart Rate Variability/Pulse Rate Variability and Amplitude Modulation signals extracted from ECG and PPG signals. The technique was validated with respect to a Respiratory Impedance Pneumography (RIP) signal using the mean absolute and the average relative errors for a group ambulatory hospital patients. We compared approaches using single respiration-induced modulations on the ECG and PPG signals with approaches fusing the different modulations. Additionally, we investigated whether the presence of both the simultaneously recorded ECG and PPG signals provided a benefit in the overall system performance. Our method outperformed state-of-the-art ECG- and PPG-based algorithms and gave the best results over the whole database with a mean error of 1.8bpm for 1min estimates when using the fused ECG modulations, which was a relative error of 10.3%. No statistically significant differences were found when comparing the ECG-, PPG- and ECG/PPG-based approaches, indicating that the PPG can be used as a valid alternative to the ECG for applications using wearable sensors. While the presence of both the ECG and PPG signals did not provide an improvement in the estimation error, it increased the proportion of windows for which an estimate was obtained by at least 9%, indicating that the use of two simultaneously recorded signals might be desirable in high-acuity cases where an RR estimate is required more frequently. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition

    PubMed Central

    Fong, Ee-May; Chung, Wan-Young

    2015-01-01

    A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject’s skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3–15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio. PMID:26251913

  1. A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition.

    PubMed

    Fong, Ee-May; Chung, Wan-Young

    2015-08-05

    A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject's skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3-15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio.

  2. Smartphone ECG for evaluation of ST-segment elevation myocardial infarction (STEMI): Design of the ST LEUIS International Multicenter Study.

    PubMed

    Barbagelata, Alejandro; Bethea, Charles F; Severance, Harry W; Mentz, Robert J; Albert, David; Barsness, Gregory W; Le, Viet T; Anderson, Jeffrey L; Bunch, T Jared; Yanowitz, Frank; Chisum, Benjamin; Ronnow, Brianna S; Muhlestein, Joseph B

    In patients experiencing an ST-elevation myocardial infarction (STEMI), rapid diagnosis and immediate access to reperfusion therapy leads to optimal clinical outcomes. The rate-limiting step in STEMI diagnosis is the availability and performance of a 12-lead ECG. Recent technology has provided access to a reliable means of obtaining an ECG reading through a smartphone application (app) that works with an attachment providing all 12-leads of a standard ECG system. The ST LEUIS study was designed to validate the smartphone ECG app and its ability to accurately assess the presence or absence of STEMI in patients presenting with chest pain compared with the gold standard 12-lead ECG. We aimed to support the diagnostic utility of smartphone technology to provide a timely diagnosis and treatment of STEMI. The study will take place over 12months at five institutions. Approximately 60 patients will be enrolled per institution, for a total recruitment of 300 patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. The evaluation of an open source online training system for teaching 12 lead electrocardiographic interpretation.

    PubMed

    Breen, Cathal; Zhu, Tingting; Bond, Raymond; Finlay, Dewar; Clifford, Gari

    2016-01-01

    The aim of this study is to present and evaluate the integration of a low resource JavaScript based ECG training interface (CrowdLabel) and a standardised curriculum for self-guided tuition in ECG interpretation. Participants practiced interpreting ECGs weekly using the CrowdLabel interface to assist with the learning of the traditional didactic taught course material during a 6 week training period. To determine competency students were tested during week 7. A total of 245 unique ECG cases were submitted by each student. Accuracy scores during the training period ranged from 0-59.5% (median = 33.3%). Conversely accuracy scores during the test ranged from 30 - 70% (median = 37.5%) (p < 0.05). There was no correlation between students who interpreted high numbers of ECGs during the training period and their marks obtained. CrowdLabel is shown to be a readily accessible dedicated learning platform to support ECG interpretation competency. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Statistical performance evaluation of ECG transmission using wireless networks.

    PubMed

    Shakhatreh, Walid; Gharaibeh, Khaled; Al-Zaben, Awad

    2013-07-01

    This paper presents simulation of the transmission of biomedical signals (using ECG signal as an example) over wireless networks. Investigation of the effect of channel impairments including SNR, pathloss exponent, path delay and network impairments such as packet loss probability; on the diagnosability of the received ECG signal are presented. The ECG signal is transmitted through a wireless network system composed of two communication protocols; an 802.15.4- ZigBee protocol and an 802.11b protocol. The performance of the transmission is evaluated using higher order statistics parameters such as kurtosis and Negative Entropy in addition to the common techniques such as the PRD, RMS and Cross Correlation.

  5. A regional prehospital electrocardiogram network with a single telecardiology "hub" for public emergency medical service: technical requirements, logistics, manpower, and preliminary results.

    PubMed

    Brunetti, Natale Daniele; De Gennaro, Luisa; Dellegrottaglie, Giulia; Amoruso, Daniele; Antonelli, Gianfranco; Di Biase, Matteo

    2011-11-01

    In patients with a major cardiac event, the first priority is to minimize time-to-treatment. For many patients, the first and fastest contact with the health system is through emergency medical services (EMS). However, delay to treatment is still significant in developed countries, and international guidelines therefore recommend that EMS use prehospital electrocardiogram (ECG). Many communities are implementing prehospital ECG programs, with different technical solutions. We report on a region-wide prehospital ECG telecardiology program that involved 233,657 patients from all over Apulia (4 million inhabitants), Italy, who called the public regional free EMS telephone number "118." Prehospital ECG was transmitted by mobile phone to a single regional telecardiology "hub" where a cardiologist available 24/7 promptly reported the ECG, having a briefing with on-scene EMS personnel and EMS district central; patients were then directed to fibrinolysis or primary percutaneous coronary intervention (PCI) as appropriate. Patients were >70 years in 51% of cases, and 55% of prehospital ECGs were unremarkable; the remaining 45% showed signs suggesting acute coronary syndrome (ACS) in 18%, arrhythmias in 20%, and minor findings in 62%. In cases of suspected ACS (chest pain), ECG findings were normal in 77% of patients; 74% of subjects with suspected ACS were screened within 30' from the onset of symptoms. A regional single telecardiology hub providing prehospital ECG for a sole regional public EMS provides an example of a prehospital ECG network optimizing quality of ECG report and uniformity of EMS assistance in a large region-wide network.

  6. A Wearable Healthcare System With a 13.7 μA Noise Tolerant ECG Processor.

    PubMed

    Izumi, Shintaro; Yamashita, Ken; Nakano, Masanao; Kawaguchi, Hiroshi; Kimura, Hiromitsu; Marumoto, Kyoji; Fuchikami, Takaaki; Fujimori, Yoshikazu; Nakajima, Hiroshi; Shiga, Toshikazu; Yoshimoto, Masahiko

    2015-10-01

    To prevent lifestyle diseases, wearable bio-signal monitoring systems for daily life monitoring have attracted attention. Wearable systems have strict size and weight constraints, which impose significant limitations of the battery capacity and the signal-to-noise ratio of bio-signals. This report describes an electrocardiograph (ECG) processor for use with a wearable healthcare system. It comprises an analog front end, a 12-bit ADC, a robust Instantaneous Heart Rate (IHR) monitor, a 32-bit Cortex-M0 core, and 64 Kbyte Ferroelectric Random Access Memory (FeRAM). The IHR monitor uses a short-term autocorrelation (STAC) algorithm to improve the heart-rate detection accuracy despite its use in noisy conditions. The ECG processor chip consumes 13.7 μA for heart rate logging application.

  7. Android based self-diagnostic electrocardiogram system for mobile healthcare.

    PubMed

    Choo, Kan-Yeep; Ling, Huo-Chong; Lo, Yew-Chiong; Yap, Zuo-Han; Pua, Jun-Sheng; Phan, Raphael C-W; Goh, Vik-Tor

    2015-01-01

    Cardiovascular diseases are the most common cause of death worldwide and are characterized by arrhythmia (i.e. irregular rhythm of heartbeat). Arrhythmia occasionally happens under certain conditions, such as stress. Therefore, it is difficult to be diagnosed using electrocardiogram (ECG) devices available in hospitals for just a few minutes. Constant diagnosis and monitoring of heartbeat is required to reduce death caused by cardiovascular diseases. Mobile healthcare system has emerged as a potential solution to assist patients in monitoring their own heart condition, especially those who are isolated from the reference hospital. This paper proposes a self-diagnostic electrocardiogram system for mobile healthcare that has the capability to perform a real-time ECG diagnostic. The self-diagnostic capability of a real-time ECG signal is achieved by implementing a detrended fluctuation analysis (DFA) method. The result obtained from DFA is used to display the patient's health condition on a smartphone anytime and anywhere. If the health condition is critical, the system will alert the patient and his medical practitioner for further diagnosis. Experimental results verified the validity of the developed ECG diagnostic application on a smartphone. The proposed system can potentially reduce death caused by cardiovascular diseases by alerting the patient possibly undergoing a heart attack.

  8. A Cardiac Early Warning System with Multi Channel SCG and ECG Monitoring for Mobile Health

    PubMed Central

    Sahoo, Prasan Kumar; Thakkar, Hiren Kumar; Lee, Ming-Yih

    2017-01-01

    Use of information and communication technology such as smart phone, smart watch, smart glass and portable health monitoring devices for healthcare services has made Mobile Health (mHealth) an emerging research area. Coronary Heart Disease (CHD) is considered as a leading cause of death world wide and an increasing number of people die prematurely due to CHD. Under such circumstances, there is a growing demand for a reliable cardiac monitoring system to catch the intermittent abnormalities and detect critical cardiac behaviors which lead to sudden death. Use of mobile devices to collect Electrocardiography (ECG), Seismocardiography (SCG) data and efficient analysis of those data can monitor a patient’s cardiac activities for early warning. This paper presents a novel cardiac data acquisition method and combined analysis of Electrocardiography (ECG) and multi channel Seismocardiography (SCG) data. An early warning system is implemented to monitor the cardiac activities of a person and accuracy assessment of the early warning system is conducted for the ECG data only. The assessment shows 88% accuracy and effectiveness of our proposed analysis, which implies the viability and applicability of the proposed early warning system. PMID:28353681

  9. A Cardiac Early Warning System with Multi Channel SCG and ECG Monitoring for Mobile Health.

    PubMed

    Sahoo, Prasan Kumar; Thakkar, Hiren Kumar; Lee, Ming-Yih

    2017-03-29

    Use of information and communication technology such as smart phone, smart watch, smart glass and portable health monitoring devices for healthcare services has made Mobile Health (mHealth) an emerging research area. Coronary Heart Disease (CHD) is considered as a leading cause of death world wide and an increasing number of people die prematurely due to CHD. Under such circumstances, there is a growing demand for a reliable cardiac monitoring system to catch the intermittent abnormalities and detect critical cardiac behaviors which lead to sudden death. Use of mobile devices to collect Electrocardiography (ECG), Seismocardiography (SCG) data and efficient analysis of those data can monitor a patient's cardiac activities for early warning. This paper presents a novel cardiac data acquisition method and combined analysis of Electrocardiography (ECG) and multi channel Seismocardiography (SCG) data. An early warning system is implemented to monitor the cardiac activities of a person and accuracy assessment of the early warning system is conducted for the ECG data only. The assessment shows 88% accuracy and effectiveness of our proposed analysis, which implies the viability and applicability of the proposed early warning system.

  10. Electrocardiographic left ventricular hypertrophy predicts recurrence of atrial arrhythmias after catheter ablation of paroxysmal atrial fibrillation.

    PubMed

    Li, Song-Nan; Wang, Lu; Dong, Jian-Zeng; Yu, Rong-Hui; Long, De-Yong; Tang, Ri-Bo; Sang, Cai-Hua; Jiang, Chen-Xi; Liu, Nian; Bai, Rong; Du, Xin; Ma, Chang-Sheng

    2018-06-01

    Left ventricular hypertrophy (LVH) is an independent predictor of new-onset atrial fibrillation. Whether LVH can predict the recurrence of arrhythmia after radiofrequency catheter ablation (RFCA) in patients with paroxysmal atrial fibrillation (PAF) remains unclear. PAF patients with baseline-electrocardiographic LVH has a higher recurrence rate after RFCA procedure compared with those without LVH. A total of 436 patients with PAF undergoing first RFCA were consecutively enrolled and clustered into 2 groups based on electrocardiogram (ECG) findings: non-ECG LVH (218 patients) and ECG LVH (218 patients). LVH was characterized by the Romhilt-Estes point score system; the score ≥5points were defined as LVH. At 42 months' (interquartile range, 18.0-60.0 months) follow-up after RFCA, 151 (69.3%) patients in the non-ECG LVH group and 108 (49.5%) patients in the ECG LVH group maintained sinus rhythm without using antiarrhythmic drugs (P < 0.001). Patients with ECG LVH tended to experience a much higher prevalence of stroke and recurrence of atrial arrhythmia episodes compared with those without ECG LVH (log-rank P < 0.001). Multivariate analysis found the presence of ECG LVH and left atrial diameter to be independent risk factors for recurrence after adjusting for confounding factors. The presence of ECG LVH was a strong and independent predictor of recurrence in patients with PAF following RFCA. © 2018 Wiley Periodicals, Inc.

  11. Interoperability in digital electrocardiography: harmonization of ISO/IEEE x73-PHD and SCP-ECG.

    PubMed

    Trigo, Jesús D; Chiarugi, Franco; Alesanco, Alvaro; Martínez-Espronceda, Miguel; Serrano, Luis; Chronaki, Catherine E; Escayola, Javier; Martínez, Ignacio; García, José

    2010-11-01

    The ISO/IEEE 11073 (x73) family of standards is a reference frame for medical device interoperability. A draft for an ECG device specialization (ISO/IEEE 11073-10406-d02) has already been presented to the Personal Health Device (PHD) Working Group, and the Standard Communications Protocol for Computer-Assisted ElectroCardioGraphy (SCP-ECG) Standard for short-term diagnostic ECGs (EN1064:2005+A1:2007) has recently been approved as part of the x73 family (ISO 11073-91064:2009). These factors suggest the coordinated use of these two standards in foreseeable telecardiology environments, and hence the need to harmonize them. Such harmonization is the subject of this paper. Thus, a mapping of the mandatory attributes defined in the second draft of the ISO/IEEE 11073-10406-d02 and the minimum SCP-ECG fields is presented, and various other capabilities of the SCP-ECG Standard (such as the messaging part) are also analyzed from an x73-PHD point of view. As a result, this paper addresses and analyzes the implications of some inconsistencies in the coordinated use of these two standards. Finally, a proof-of-concept implementation of the draft x73-PHD ECG device specialization is presented, along with the conversion from x73-PHD to SCP-ECG. This paper, therefore, provides recommendations for future implementations of telecardiology systems that are compliant with both x73-PHD and SCP-ECG.

  12. Detection of Electrocardiogram by Electrodes with Fabrics Using Capacitive Coupling

    NASA Astrophysics Data System (ADS)

    Ueno, Akinori; Furusawa, Yoichi; Hoshino, Hiroshi; Ishiyama, Yoji

    This article reports on a novel technique for detecting electrocardiogram (ECG) at a condition where thin cloth is interpolated between sensing electrodes and the skin to which the electrodes are attached. The technique is based upon capacitive coupling composed of the electrode, the cloth and the skin, so that the electrode can lead alternating electrocardiographic current through capacitance of the coupling. The technique is also founded on impedance transforming circuit that has extremely high input impedance around 1000GΩ and low output impedance, so as to match high output impedance of the electrode to low input impedance required by subsequent circuitry. A pilot ECG measuring device was manufactured using the technique and experiments showed (1) ECG recordings using the device with silk of 240μm thickness or with cotton of 564μm thickness were quite similar to ECGs recorded from the skin using conventional system, (2) stable ECGs were observed with the silk below 600μm thickness or with the cotton below 1128μm thickness, (3) effects of long-term measurement and perspiration on ECG waveform were negligible. These results prove feasibility of the proposed technique for detecting ECG by electrodes with fabrics.

  13. Heart rate calculation from ensemble brain wave using wavelet and Teager-Kaiser energy operator.

    PubMed

    Srinivasan, Jayaraman; Adithya, V

    2015-01-01

    Electroencephalogram (EEG) signal artifacts are caused by various factors, such as, Electro-oculogram (EOG), Electromyogram (EMG), Electrocardiogram (ECG), movement artifact and line interference. The relatively high electrical energy cardiac activity causes EEG artifacts. In EEG signal processing the general approach is to remove the ECG signal. In this paper, we introduce an automated method to extract the ECG signal from EEG using wavelet and Teager-Kaiser energy operator for R-peak enhancement and detection. From the detected R-peaks the heart rate (HR) is calculated for clinical diagnosis. To check the efficiency of our method, we compare the HR calculated from ECG signal recorded in synchronous with EEG. The proposed method yields a mean error of 1.4% for the heart rate and 1.7% for mean R-R interval. The result illustrates that, proposed method can be used for ECG extraction from single channel EEG and used in clinical diagnosis like estimation for stress analysis, fatigue, and sleep stages classification studies as a multi-model system. In addition, this method eliminates the dependence of additional synchronous ECG in extraction of ECG from EEG signal process.

  14. Implementation of national practice guidelines to reduce waste and optimize patient value.

    PubMed

    Langell, John T; Bledsoe, Amber; Vijaykumar, Sathya; Anderson, Terry; Zawalski, Ivy; Zimmerman, Joshua

    2016-06-15

    The financial health care crisis has provided the platform to drive operational improvements at US health care facilities. This has led to adoption of lean operation principles by many health care organizations as a means of eliminating waste and improving operational efficiencies and overall value to patients. We believe that standardized implementation of national practice guidelines can provide the framework to help to reduce financial waste. We analyzed our institutional preoperative electrocardiogram (ECG) ordering practices for patients undergoing elective surgery at our institution from February-March, 2012 to identify utilization and review compliance with American Heart Association guidelines. We then implemented an ECG ordering algorithm based on these guidelines and studied changes in ordering patterns, associated cost savings and hospital billing for the same period in 2013. From February-March 2012, 677 noncardiac surgical procedures were performed at our institution, and 312 (46.1%) had a preoperative ECG. After implementation of our evidence-based ECG ordering algorithm for the same period in 2013, 707 noncardiac surgical cases were performed, and 120 (16.9%) had a preoperative ECG. Preoperative ECG utilization dropped 63% with an annual institutional cost savings of $72,906 and $291,618 in total annual health care savings. Based on our data, US-wide implementation of our evidence-based ECG ordering algorithm could save the US health care system >$1,868,800,000 per year. Here, we demonstrate that standardized application of a national practice guideline can be used to eliminate nearly $2 billion per year in waste from the US health care system. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Functions of ectopically transplanted invasive horse trophoblast

    PubMed Central

    de Mestre, Amanda M.; Hanlon, David; Adams, A. Paige; Runcan, Erin; Leadbeater, Jane C.; Erb, Hollis N.; Costa, Christina C.; Miller, Donald; Allen, W. R; Antczak, Douglas F.

    2013-01-01

    The invasive and fully antigenic trophoblast of the chorionic girdle portion of the equine fetal membranes has the capacity to survive and differentiate after transplantation to ectopic sites. The objectives of this study were to determine: (i) the survival time of ectopically transplanted allogeneic trophoblast cells in non-pregnant recipient mares, (ii) whether equine Chorionic Gonadotrophin (eCG) can be delivered systemically by transplanted chorionic girdle cells, and (iii) if eCG delivered by the transplanted cells is biologically active and can suppress behavioral signs associated with estrus. Ectopically transplanted chorionic girdle survived for up to 105 days with a mean lifespan of 75 days (95% CI 55–94), and secreted sufficient eCG for the hormone to be measurable in the recipients’ circulation. Immunohistochemical labeling of serial biopsies of the transplant sites and measurement of eCG profiles demonstrated that graft survival was similar to the lifespan of equine endometrial cups in normal horse pregnancy. The eCG secreted by the transplanted cells induced corpora lutea formation and sustained systemic progesterone levels in the recipient mares, effects that are also observed during pregnancy. This in turn caused suppression of estrus behavior in the recipients for up to three months. Thus, ectopically transplanted equine trophoblast provides an unusual example of sustained viability and function of an immunogenic transplant in a recipient with an intact immune system. This model highlights the importance of innate immunoregulatory capabilities of invasive trophoblast cells and describes a new method to deliver sustained circulating concentrations of eCG in non-pregnant mares. PMID:21389079

  16. Study of ECG changes and its relation to mortality in cases of cerebrovascular accidents.

    PubMed

    Purushothaman, Suja; Salmani, Deepalaxmi; Prarthana, Kaleramma Gopalakrishna; Bandelkar, Srinidhi Muddanna Gundappa; Varghese, Sarah

    2014-07-01

    Its being long recognized about the highly debilitating and destructive nature of cerebrovascular accidents (CVAs). Around the world CVAs has posed as a major factor in medical morbidity and mortality. It has thrown up challenges with regards to their medical management and also towards posttreatment rehabilitation. It is well-known that neurologic disorder contributes variously towards varied electrocardiogram (ECG) changes and stroke is no exception. To study the ECG changes and its relation to mortality in cases of CVA. A total of 100 patients with acute stroke were enrolled in the study. All the 100 patients underwent ECG recording within first 24 h of admission. The patients were divided into ischemic and hemorrhagic group depending on the nature of lesion. Out of 100 cases, 58 were ischemic and 42 were hemorrhagic. The ECG changes were noted in 78 patients. Among the ischemic group, the changes noted in the ECG were: T wave inversion (34.48%), ST segment depression (32.75%), QTc prolongation (29.31%), and presence of U waves (27.58%). In cases of hemorrhagic stroke, it was: T wave inversion (33.33%), arrhythmias (33.33%), U waves (30.95%), and ST segment depression (23.80%). Mortality was higher in patients with ST-T changes in ischemic group (66.66%) and in patients with positive U waves (60%) in hemorrhagic group. In acute stroke patients, changes in ECG were commonly seen. The changes varied from T-wave inversion to ST segment depression in ischemic stroke. In hemorrhagic stroke it consisted of T wave inversion and arrhythmias. Overall mortality was high in cases of hemorrhagic compared to ischemic group.

  17. Study of ECG changes and its relation to mortality in cases of cerebrovascular accidents

    PubMed Central

    Purushothaman, Suja; Salmani, Deepalaxmi; Prarthana, Kaleramma Gopalakrishna; Bandelkar, Srinidhi Muddanna Gundappa; Varghese, Sarah

    2014-01-01

    Background: Its being long recognized about the highly debilitating and destructive nature of cerebrovascular accidents (CVAs). Around the world CVAs has posed as a major factor in medical morbidity and mortality. It has thrown up challenges with regards to their medical management and also towards posttreatment rehabilitation. It is well-known that neurologic disorder contributes variously towards varied electrocardiogram (ECG) changes and stroke is no exception. Objective: To study the ECG changes and its relation to mortality in cases of CVA. Materials and Methods: A total of 100 patients with acute stroke were enrolled in the study. All the 100 patients underwent ECG recording within first 24 h of admission. The patients were divided into ischemic and hemorrhagic group depending on the nature of lesion. Results: Out of 100 cases, 58 were ischemic and 42 were hemorrhagic. The ECG changes were noted in 78 patients. Among the ischemic group, the changes noted in the ECG were: T wave inversion (34.48%), ST segment depression (32.75%), QTc prolongation (29.31%), and presence of U waves (27.58%). In cases of hemorrhagic stroke, it was: T wave inversion (33.33%), arrhythmias (33.33%), U waves (30.95%), and ST segment depression (23.80%). Mortality was higher in patients with ST-T changes in ischemic group (66.66%) and in patients with positive U waves (60%) in hemorrhagic group. Conclusion: In acute stroke patients, changes in ECG were commonly seen. The changes varied from T-wave inversion to ST segment depression in ischemic stroke. In hemorrhagic stroke it consisted of T wave inversion and arrhythmias. Overall mortality was high in cases of hemorrhagic compared to ischemic group. PMID:25097430

  18. Diagnostic performance of coronary computed tomography angiography versus exercise electrocardiography for coronary artery disease: a systematic review and meta-analysis

    PubMed Central

    Yin, Xinxin; Zheng, Wen; Ma, Jingjing; Hao, Panpan

    2016-01-01

    Background Both coronary computed tomography angiography (CCTA) and exercise electrocardiography (ExECG) are non-invasive testing methods for the evaluation of coronary artery disease (CAD). However, there was controversy on the diagnostic performance of these methods due to the limited data in each single study. Therefore, we performed a meta-analysis to address these issues. Methods We searched PubMed and Embase databases up to May 22, 2015. Two authors identified eligible studies, extracted data and accessed quality. Pooled estimation of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), summary receiver-operating characteristic curve (SROC) and the area under curve (AUC) of CCTA and ExECG for the diagnosis of CAD were calculated using Stata, Meta-Disc and Review Manager statistical software. Results Seven articles were included. Pooled sensitivity of CCTA and ExECG were 0.98 [95% confidence intervals (CIs): 0.95–0.99] and 0.66 (95% CIs: 0.59–0.72); pooled specificity of CCTA and ExECG were 0.84 (95% CIs: 0.81–0.87) and 0.75 (95% CIs: 0.71–0.79); pooled DOR of CCTA and ExECG were 110.24 (95% CIs: 35.07–346.55) and 6.28 (95% CIs: 2.06–19.13); and AUC of CCTA and ExECG were 0.9950±0.0046 and 0.7727±0.0638, respectively. There is no heterogeneity caused by threshold effect in CCTA or ExECG analysis. The Deeks’ test showed no potential publication bias (P=0.17). Conclusions CCTA has better diagnostic performance than ExECG in the evaluation of CAD, which can provide a better solution for the clinical problem of the diagnosis for CAD. PMID:27499958

  19. New System for Digital to Analog Transformation and Reconstruction of 12-Lead ECGs

    PubMed Central

    Kothadia, Roshni; Kulecz, Walter B.; Kofman, Igor S.; Black, Adam J.; Grier, James W.; Schlegel, Todd T.

    2013-01-01

    Introduction We describe initial validation of a new system for digital to analog conversion (DAC) and reconstruction of 12-lead ECGs. The system utilizes an open and optimized software format with a commensurately optimized DAC hardware configuration to accurately reproduce, from digital files, the original analog electrocardiographic signals of previously instrumented patients. By doing so, the system also ultimately allows for transmission of data collected on one manufacturer's 12-lead ECG hardware/software into that of any other. Materials and Methods To initially validate the system, we compared original and post-DAC re-digitized 12-lead ECG data files (∼5-minutes long) in two types of validation studies in 10 patients. The first type quantitatively compared the total waveform voltage differences between the original and re-digitized data while the second type qualitatively compared the automated electrocardiographic diagnostic statements generated by the original versus re-digitized data. Results The grand-averaged difference in root mean squared voltage between the original and re-digitized data was 20.8 µV per channel when re-digitization involved the same manufacturer's analog to digital converter (ADC) as the original digitization, and 28.4 µV per channel when it involved a different manufacturer's ADC. Automated diagnostic statements generated by the original versus reconstructed data did not differ when using the diagnostic algorithm from the same manufacturer on whose device the original data were collected, and differed only slightly for just 1 of 10 patients when using a third-party diagnostic algorithm throughout. Conclusion Original analog 12-lead ECG signals can be reconstructed from digital data files with accuracy sufficient for clinical use. Such reconstructions can readily enable automated second opinions for difficult-to-interpret 12-lead ECGs, either locally or remotely through the use of dedicated or cloud-based servers. PMID:23613787

  20. Compressed ECG biometric: a fast, secured and efficient method for identification of CVD patient.

    PubMed

    Sufi, Fahim; Khalil, Ibrahim; Mahmood, Abdun

    2011-12-01

    Adoption of compression technology is often required for wireless cardiovascular monitoring, due to the enormous size of Electrocardiography (ECG) signal and limited bandwidth of Internet. However, compressed ECG must be decompressed before performing human identification using present research on ECG based biometric techniques. This additional step of decompression creates a significant processing delay for identification task. This becomes an obvious burden on a system, if this needs to be done for a trillion of compressed ECG per hour by the hospital. Even though the hospital might be able to come up with an expensive infrastructure to tame the exuberant processing, for small intermediate nodes in a multihop network identification preceded by decompression is confronting. In this paper, we report a technique by which a person can be identified directly from his / her compressed ECG. This technique completely obviates the step of decompression and therefore upholds biometric identification less intimidating for the smaller nodes in a multihop network. The biometric template created by this new technique is lower in size compared to the existing ECG based biometrics as well as other forms of biometrics like face, finger, retina etc. (up to 8302 times lower than face template and 9 times lower than existing ECG based biometric template). Lower size of the template substantially reduces the one-to-many matching time for biometric recognition, resulting in a faster biometric authentication mechanism.

  1. Screening for Cardiovascular Disease Risk With Electrocardiography: US Preventive Services Task Force Recommendation Statement.

    PubMed

    Curry, Susan J; Krist, Alex H; Owens, Douglas K; Barry, Michael J; Caughey, Aaron B; Davidson, Karina W; Doubeni, Chyke A; Epling, John W; Kemper, Alex R; Kubik, Martha; Landefeld, C Seth; Mangione, Carol M; Silverstein, Michael; Simon, Melissa A; Tseng, Chien-Wen; Wong, John B

    2018-06-12

    Cardiovascular disease (CVD), which encompasses atherosclerotic conditions such as coronary heart disease, cerebrovascular disease, and peripheral arterial disease, is the most common cause of death among adults in the United States. Treatment to prevent CVD events by modifying risk factors is currently informed by CVD risk assessment with tools such as the Framingham Risk Score or the Pooled Cohort Equations, which stratify individual risk to inform treatment decisions. To update the 2012 US Preventive Services Task Force (USPSTF) recommendation on screening for coronary heart disease with electrocardiography (ECG). The USPSTF reviewed the evidence on whether screening with resting or exercise ECG improves health outcomes compared with the use of traditional CVD risk assessment alone in asymptomatic adults. For asymptomatic adults at low risk of CVD events (individuals with a 10-year CVD event risk less than 10%), it is very unlikely that the information from resting or exercise ECG (beyond that obtained with conventional CVD risk factors) will result in a change in the patient's risk category as assessed by the Framingham Risk Score or Pooled Cohort Equations that would lead to a change in treatment and ultimately improve health outcomes. Possible harms are associated with screening with resting or exercise ECG, specifically the potential adverse effects of subsequent invasive testing. For asymptomatic adults at intermediate or high risk of CVD events, there is insufficient evidence to determine the extent to which information from resting or exercise ECG adds to current CVD risk assessment models and whether information from the ECG results in a change in risk management and ultimately reduces CVD events. As with low-risk adults, possible harms are associated with screening with resting or exercise ECG in asymptomatic adults at intermediate or high risk of CVD events. The USPSTF recommends against screening with resting or exercise ECG to prevent CVD events in asymptomatic adults at low risk of CVD events. (D recommendation) The USPSTF concludes that the current evidence is insufficient to assess the balance of benefits and harms of screening with resting or exercise ECG to prevent CVD events in asymptomatic adults at intermediate or high risk of CVD events. (I statement).

  2. A reference architecture for telemonitoring.

    PubMed

    Clarke, Malcolm

    2004-01-01

    The Telecare Interactive Continuous Monitoring System exploits GPRS to provide an ambulatory device that monitors selected vital signs on a continuous basis. Alarms are sent when parameters fall outside preset limits, and accompanying physiological data may also be transmitted. The always-connected property of GPRS allows continuous interactive control of the device and its sensors, permitting changes to monitoring parameters or even enabling continuous monitoring of a sensor in emergency. A new personal area network (PAN) has been developed to support short-range wireless connection to sensors worn on the body including ECG and finger worn SpO2. Most notable is use of ultra low radio frequency to reduce power to minimum. The system has been designed to use a hierarchical architecture for sensors and "derived" signals, such as HR from ECG, so that each can be independently controlled and managed. Sensors are treated as objects, and functions are defined to control aspects of behaviour. These are refined in order to define a generic set of abstract functions to handle the majority of functions, leaving a minimum of sensor specific commands. The intention is to define a reference architecture in order to research the functionality and system architecture of a telemonitoring system. The Telecare project is funded through a grant from the European Commission (IST programme).

  3. Wavelet approach to artifact noise removal from Capacitive coupled Electrocardiograph.

    PubMed

    Lee, Seung Min; Kim, Ko Keun; Park, Kwang Suk

    2008-01-01

    Capacitive coupled Electrocardiography (ECG) is introduced as non-invasive measurement technology for ubiquitous health care and appliance are spread out widely. Although it has many merits, however, capacitive coupled ECG is very weak for motion artifacts for its non-skin-contact property. There are many studies for artifact problems which treats all artifact signals below 0.8Hz. In our capacitive coupled ECG measurement system, artifacts exist not only below 0.8Hz but also over than 10Hz. Therefore, artifact noise removal algorithm using wavelet method is tested to reject artifact-wandered signal from measured signals. It is observed that using power calculation each decimation step, artifact-wandered signal is removed as low frequency artifacts as high frequency artifacts. Although some original ECG signal is removed with artifact signal, we could level the signal quality for long term measure which shows the best quality ECG signals as we can get.

  4. ECG Based Heart Arrhythmia Detection Using Wavelet Coherence and Bat Algorithm

    NASA Astrophysics Data System (ADS)

    Kora, Padmavathi; Sri Rama Krishna, K.

    2016-12-01

    Atrial fibrillation (AF) is a type of heart abnormality, during the AF electrical discharges in the atrium are rapid, results in abnormal heart beat. The morphology of ECG changes due to the abnormalities in the heart. This paper consists of three major steps for the detection of heart diseases: signal pre-processing, feature extraction and classification. Feature extraction is the key process in detecting the heart abnormality. Most of the ECG detection systems depend on the time domain features for cardiac signal classification. In this paper we proposed a wavelet coherence (WTC) technique for ECG signal analysis. The WTC calculates the similarity between two waveforms in frequency domain. Parameters extracted from WTC function is used as the features of the ECG signal. These features are optimized using Bat algorithm. The Levenberg Marquardt neural network classifier is used to classify the optimized features. The performance of the classifier can be improved with the optimized features.

  5. Atrial Fibrillation Screening in Nonmetropolitan Areas Using a Telehealth Surveillance System With an Embedded Cloud-Computing Algorithm: Prospective Pilot Study

    PubMed Central

    Chen, Ying-Hsien; Hung, Chi-Sheng; Huang, Ching-Chang; Hung, Yu-Chien

    2017-01-01

    Background Atrial fibrillation (AF) is a common form of arrhythmia that is associated with increased risk of stroke and mortality. Detecting AF before the first complication occurs is a recognized priority. No previous studies have examined the feasibility of undertaking AF screening using a telehealth surveillance system with an embedded cloud-computing algorithm; we address this issue in this study. Objective The objective of this study was to evaluate the feasibility of AF screening in nonmetropolitan areas using a telehealth surveillance system with an embedded cloud-computing algorithm. Methods We conducted a prospective AF screening study in a nonmetropolitan area using a single-lead electrocardiogram (ECG) recorder. All ECG measurements were reviewed on the telehealth surveillance system and interpreted by the cloud-computing algorithm and a cardiologist. The process of AF screening was evaluated with a satisfaction questionnaire. Results Between March 11, 2016 and August 31, 2016, 967 ECGs were recorded from 922 residents in nonmetropolitan areas. A total of 22 (2.4%, 22/922) residents with AF were identified by the physician’s ECG interpretation, and only 0.2% (2/967) of ECGs contained significant artifacts. The novel cloud-computing algorithm for AF detection had a sensitivity of 95.5% (95% CI 77.2%-99.9%) and specificity of 97.7% (95% CI 96.5%-98.5%). The overall satisfaction score for the process of AF screening was 92.1%. Conclusions AF screening in nonmetropolitan areas using a telehealth surveillance system with an embedded cloud-computing algorithm is feasible. PMID:28951384

  6. [An ultra-low power, wearable, long-term ECG monitoring system with mass storage].

    PubMed

    Liu, Na; Chen, Yingmin; Zhang, Wenzan; Luo, Zhangyuan; Jin, Xun; Ying, Weihai

    2012-01-01

    In this paper, we described an ultra-low power, wearable ECG system capable of long term monitoring and mass storage. This system is based on micro-chip PIC18F27J13 with consideration of its high level of integration and low power consumption. The communication with the micro-SD card is achieved through SPI bus. Through the USB, it can be connected to the computer for replay and disease diagnosis. Given its low power cost, lithium cells are used to support continuous ECG acquiring and storage for up to 15 days. Meanwhile, the wearable electrodes avoid the pains and possible risks in implanting. Besides, the mini size of the system makes long wearing possible for patients and meets the needs of long-term dynamic monitoring and mass storage requirements.

  7. Single frequency RF powered ECG telemetry system

    NASA Technical Reports Server (NTRS)

    Ko, W. H.; Hynecek, J.; Homa, J.

    1979-01-01

    It has been demonstrated that a radio frequency magnetic field can be used to power implanted electronic circuitry for short range telemetry to replace batteries. A substantial reduction in implanted volume can be achieved by using only one RF tank circuit for receiving the RF power and transmitting the telemetered information. A single channel telemetry system of this type, using time sharing techniques, was developed and employed to transmit the ECG signal from Rhesus monkeys in primate chairs. The signal from the implant is received during the period when the RF powering radiation is interrupted. The ECG signal is carried by 20-microsec pulse position modulated pulses, referred to the trailing edge of the RF powering pulse. Satisfactory results have been obtained with this single frequency system. The concept and the design presented may be useful for short-range long-term implant telemetry systems.

  8. Heart Rhythm Monitoring in the Constellation Lunar and Launch/Landing EVA Suit: Recommendations from an Expert Panel

    NASA Technical Reports Server (NTRS)

    Scheuring, Richard A.; Hamilton, D.; Jones, J. A.; Alexander, D.

    2008-01-01

    Currently there are several physiological monitoring requirements for Extravehicular Activity (EVA) in the Human-Systems Interface Requirements (HSIR) document, including continuous heart rhythm monitoring. However, it is not known whether heart rhythm monitoring in the lunar surface space suit is a necessary capability for lunar surface operations or in launch/landing suit the event of a cabin depressurization enroute to or from the moon. Methods: Current US astronaut corps demographic information was provided to an expert panel of cardiovascular medicine experts, including specialists in electrophysiology, exercise physiology, interventional cardiology and arrhythmia. This information included averages for male/female age, body mass index (BMI), blood pressure, cholesterol, inflammatory markers, echocardiogram, ranges for coronary artery calcium (CAC) scores for long duration astronauts, and ranges for heart rate (HR) and metabolic (MET) rates obtained during microgravity and lunar EVA. Results: The panel determined that no uncontrolled hazard was likely to occur in the suit during lunar surface or contingency microgravity ops that would require ECG monitoring in the highly screened US astronaut population. However having the capability for rhythm monitoring inside the vehicle (IVA) was considered critical to manage an astronaut in distress. Discussion: Heart rate (HR) monitoring alone allows effective monitoring of astronaut health and function. Consequently, electrocardiographic (ECG) monitoring capability as a clinical tool is not essential in the lunar or launch/landing space suit. However, the panel considered that rhythm monitoring could be useful in certain clinical situations, it was not considered required for safe operations. Also, lunar vehicles should be required to have ECG monitoring capability with a minimum of 5-lead ECG (derived 12- lead) for IVA medical assessments.

  9. Drug safety of macrolide and quinolone antibiotics in a tertiary care hospital: administration of interacting co-medication and QT prolongation.

    PubMed

    Niedrig, David; Maechler, Sarah; Hoppe, Liesa; Corti, Natascia; Kovari, Helen; Russmann, Stefan

    2016-07-01

    Some macrolide and quinolone antibiotics (MQABs) are associated with QT prolongation and life-threatening torsade de pointes (TdP) arrhythmia. MQAB may also inhibit cytochrome P450 isoenzymes and thereby cause pharmacokinetic drug interactions (DDIs). There is limited data on the frequency and management of such risks in clinical practice. We aimed to quantify co-administration of MQAB with interacting drugs and associated adverse drug reactions. We conducted an observational study within our pharmacoepidemiological database derived from electronic medical records of a tertiary care hospital. Among all users of MQAB associated with TdP, we determined the prevalence of additional QT-prolonging drugs and risk factors and identified contraindicated co-administrations of simvastatin, atorvastatin, or tizanidine. Electrocardiographic (ECG) monitoring and associated adverse events were validated in medical records. Among 3444 administered courses of clarithromycin, erythromycin, azithromycin, ciprofloxacin, levofloxacin, or moxifloxacin, there were 1332 (38.7 %) with concomitant use of additional QT-prolonging drugs. Among those, we identified seven cases of drug-related QT prolongation, but 49.1 % had no ECG monitoring. Of all MQAB users, 547 (15.9 %) had hypokalemia. Forty-four MQAB users had contraindicated co-administrations of simvastatin, atorvastatin, or tizanidine and three of those related adverse drug reactions. In the studied real-life setting, we found a considerable number of MQAB users with additional risk factors for TdP but no ECG monitoring. However, adverse drug reactions were rarely found, and costs vs. benefits of ECG monitoring have to be weighted. In contrast, avoidable risk factors and selected contraindicated pharmacokinetic interactions are clear targets for implementation as automated alerts in electronic prescribing systems.

  10. Computer-based rhythm diagnosis and its possible influence on nonexpert electrocardiogram readers.

    PubMed

    Hakacova, Nina; Trägårdh-Johansson, Elin; Wagner, Galen S; Maynard, Charles; Pahlm, Olle

    2012-01-01

    Systems providing computer-based analysis of the resting electrocardiogram (ECG) seek to improve the quality of health care by providing accurate and timely automatic diagnosis of, for example, cardiac rhythm to clinicians. The accuracy of these diagnoses, however, remains questionable. We tested the hypothesis that (a) 2 independent automated ECG systems have better accuracy in rhythm diagnosis than nonexpert clinicians and (b) both systems provide correct diagnostic suggestions in a large percentage of cases where the diagnosis of nonexpert clinicians is incorrect. Five hundred ECGs were manually analyzed by 2 senior experts, 3 nonexpert clinicians, and automatically by 2 automated systems. The accuracy of the nonexpert rhythm statements was compared with the accuracy of each system statement. The proportion of rhythm statements when the clinician's diagnoses were incorrect and the systems instead provided correct diagnosis was assessed. A total of 420 sinus rhythms and 156 rhythm disturbances were recognized by expert reading. Significance of the difference in accuracy between nonexperts and systems was P = .45 for system A and P = .11 for system B. The percentage of correct automated diagnoses in cases when the clinician was incorrect was 28% ± 10% for system A and 25% ± 11% for system B (P = .09). The rhythm diagnoses of automated systems did not reach better average accuracy than those of nonexpert readings. The computer diagnosis of rhythm can be incorrect in cases where the clinicians fail in reaching the correct ECG diagnosis. Copyright © 2012. Published by Elsevier Inc.

  11. Continuous control systems for non-contact ECG

    NASA Astrophysics Data System (ADS)

    Kodkin, Vladimir L.; Yakovleva, Galina V.; Smirnov, Alexey S.

    2017-03-01

    South Ural State University is still conducting the research work dedicated to innovations in biomedicine. Development of system for continuous control and diagnosis of the functional state in large groups of people is based on studies of non-contact ECG recording reported by the authors at the SPIE conference in 2016. The next stage of studies has been performed this year.

  12. [The Key Technology Study on Cloud Computing Platform for ECG Monitoring Based on Regional Internet of Things].

    PubMed

    Yang, Shu; Qiu, Yuyan; Shi, Bo

    2016-09-01

    This paper explores the methods of building the internet of things of a regional ECG monitoring, focused on the implementation of ECG monitoring center based on cloud computing platform. It analyzes implementation principles of automatic identifi cation in the types of arrhythmia. It also studies the system architecture and key techniques of cloud computing platform, including server load balancing technology, reliable storage of massive smalfi les and the implications of quick search function.

  13. Electrocardiographic anxiety profiles improve speech anxiety.

    PubMed

    Kim, Pyoung Won; Kim, Seung Ae; Jung, Keun-Hwa

    2012-12-01

    The present study was to set out in efforts to determine the effect of electrocardiographic (ECG) feedback on the performance in speech anxiety. Forty-six high school students participated in a speech performance educational program. They were randomly divided into two groups, an experimental group with ECG feedback (N = 21) and a control group (N = 25). Feedback was given with video recording in the control, whereas in the experimental group, an additional ECG feedback was provided. Speech performance was evaluated by the Korean Broadcasting System (KBS) speech ability test, which determines the 10 different speaking categories. ECG was recorded during rest and speech, together with a video recording of the speech performance. Changes in R-R intervals were used to reflect anxiety profiles. Three trials were performed for 3-week program. Results showed that the subjects with ECG feedback revealed a significant improvement in speech performance and anxiety states, which compared to those in the control group. These findings suggest that visualization of the anxiety profile feedback with ECG can be a better cognitive therapeutic strategy in speech anxiety.

  14. Willem Einthoven and the birth of clinical electrocardiography a hundred years ago.

    PubMed

    Barold, S Serge

    2003-01-01

    The first electrocardiogram (ECG) from the intact human heart was recorded with a mercury capillary electrometer by Augustus Waller in May 1887 at St. Mary's Hospital, London. The tracings were poor and exhibited only 2 distorted deflections. Willem Einthoven (1860-1927) who was professor of physiology at the University of Leiden, The Netherlands, began his studies of the ECG with the mercury capillary electrometer, and improved its distortion mathematically so that he was finally able to register a good representation of the ECG before the beginning of the twentieth century. He later further improved ECG recordings with the introduction of a string galvanometer of his design. Einthoven published his first article about the string galvanometer in 1901, followed by a more detailed description in 1903 which included a report of ECGs taken with the new instrument. The year 2002 marks the centennial of Willem Einthoven's first recording of the ECG in a clinically applicable fashion with the string galvanometer. The clinical use of Einthoven's immobile equipment required transtelephonic transmission of the ECG from the physiology laboratory to the clinic at the Academic Hospital about a mile away as documented in the 1906 paper on the "télécardiogramme". This report contained a wealth of ECG patterns and arrhythmias. Einthoven developed a system of electrocardiographic standardization that continues to be used all over the world and introduced the triaxial bipolar system with 3 limb leads and thus established uniformity of the recording process. Einthoven also conceived the famous equilateral triangle with leads I, II, and III at its sides and the calculation of the electrical axis (in the frontal plane) depicted as a single vector with an arrow at the center of the triangle. Einthoven recognized the great potential importance of the ECG as a diagnostic and investigative tool and his achievements made him the founder of modern electrocardiography. He was awarded the Nobel Prize in 1924 (2 years after Waller's death) in physiology and medicine, "for the discovery of the mechanism of the electrocardiogram."

  15. Real-Time Analytics for the Healthcare Industry: Arrhythmia Detection.

    PubMed

    Agneeswaran, Vijay Srinivas; Mukherjee, Joydeb; Gupta, Ashutosh; Tonpay, Pranay; Tiwari, Jayati; Agarwal, Nitin

    2013-09-01

    It is time for the healthcare industry to move from the era of "analyzing our health history" to the age of "managing the future of our health." In this article, we illustrate the importance of real-time analytics across the healthcare industry by providing a generic mechanism to reengineer traditional analytics expressed in the R programming language into Storm-based real-time analytics code. This is a powerful abstraction, since most data scientists use R to write the analytics and are not clear on how to make the data work in real-time and on high-velocity data. Our paper focuses on the applications necessary to a healthcare analytics scenario, specifically focusing on the importance of electrocardiogram (ECG) monitoring. A physician can use our framework to compare ECG reports by categorization and consequently detect Arrhythmia. The framework can read the ECG signals and uses a machine learning-based categorizer that runs within a Storm environment to compare different ECG signals. The paper also presents some performance studies of the framework to illustrate the throughput and accuracy trade-off in real-time analytics.

  16. Wolff-Parkinson-white syndrome mimics a conduction disease.

    PubMed

    Marrakchi, S; Kammoun, I; Kachboura, S

    2014-01-01

    Background. It is important to recognise Wolff-Parkinson-White (WPW) syndrome in electrocardiograms (ECG), as it may mimic ischaemic heart disease, ventricular hypertrophy, and bundle branch block. Recognising WPW syndrome allows for risk stratification, the identification of associated conditions, and the institution of appropriate management. Objective. The present case showed that electrophysiological study is indicated in patients with abnormal ECG and syncope. Case Report. A 40-year-old man with Wolff-Parkinson-White syndrome was presented to emergency with syncope. A baseline ECG was a complete right branch block and posterior left hemiblock. He was admitted to the cardiac care unit for pacemaker implantation. The atypical figure of complete right branch block and posterior left hemiblock was thought to be a "false positive" of conduction abnormality. But the long anterograde refractory period of the both accessory pathway and atrioventricular conduction may cause difficulty in diagnosing Wolff-Parkinson-White syndrome, Conclusion. A Wolff-Parkinson-White Syndrome may mimic a conduction disease. No reliable algorithm exists for making an ECG diagnosis of a preexcitation syndrome with conduction disorders. This can lead to diagnostic and therapeutic dilemmas in the context of syncope.

  17. ECG-gated imaging of the left atrium and pulmonary veins: Intra-individual comparison of CTA and MRA.

    PubMed

    Fahlenkamp, U L; Lembcke, A; Roesler, R; Schwenke, C; Huppertz, A; Streitparth, F; Taupitz, M; Hamm, B; Wagner, M

    2013-10-01

    To compare electrocardiography (ECG)-gated computed tomography angiography (CTA) with ECG-gated magnetic resonance angiography (MRA) for assessment of the left atrium (LA) and pulmonary veins (PVs). Twenty-nine consecutive patients who underwent both cardiac CTA and MRA were evaluated. Contrast-enhanced CTA was performed with prospective ECG-gating using a 320 detector row CT system. Contrast-enhanced MRA was performed with prospective ECG-gating using a 1.5 T MRI system equipped with a 32 channel cardiac coil. MRA was acquired during free-breathing with a navigator-gated inversion-recovery prepared steady-state free precession sequence. Two readers independently assessed the CTA and MRA images for vascular definition of the PVs (from 0, not visualized, to 4, excellent definition) and ostial PV diameters. Variants of LA anatomy were assessed in consensus. CTA was successfully performed in all patients with a mean radiation exposure of 5.1 ± 2.2 mSv. MRA was successfully performed in 27 of 29 patients (93 %). Visual definition of PVs was rated significantly higher on CTA compared to MRA (p < 0.0001; reader 1: excellent/good ratings of CTA versus MRA: 100% versus 86%; reader 2: excellent/good ratings of CTA versus MRA: 99% versus 89%). Assessment of ostial PV diameters showed good correlation between CTA and MRA (reader 1: Pearson r = 0.91; reader 2: Pearson r = 0.82). Moreover, agreement between both imaging methods for evaluation of variants of LA anatomy was high (agreement rate of 95% (95% CI: 92-99%). ECG-gated CTA provides higher image quality compared to ECG-gated MRA. Nevertheless, both CTA and MRA provided similar information of LA anatomy and ostial PV diameters. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  18. Design and implementation of an electrocardiographical signal acquisition and digital processing system orientated to the detection of paroxysmal arrhythmias

    NASA Astrophysics Data System (ADS)

    Iriart Braceli, Agustín; Exequiel Morani, Jorge

    2011-12-01

    This article describes the design, technical aspects and implementation of a device capable of acquiring electrocardiograph signals; visualize them in real time over a graphic liquid crystal display (GLCD), and the storage of these ECG registers on a SD memory card. It also details a noise suppression algorithm using the Wavelet Transform. This system was specially developed to cover some bankruptcy that presents actual Holters or ECG regarding the detection of paroxysmal arrhythmias. The contribution of this work is settled on its portability and low production cost. The filtering method used provides an ECG signal without any significant noise and appropriate to the diagnosis of cardiac pathologies.

  19. Heart rate variability (HRV) and muscular system activity (EMG) in cases of crash threat during simulated driving of a passenger car.

    PubMed

    Zużewicz, Krystyna; Roman-Liu, Danuta; Konarska, Maria; Bartuzi, Paweł; Matusiak, Krzysztof; Korczak, Dariusz; Lozia, Zbigniew; Guzek, Marek

    2013-10-01

    The aim of the study was to verify whether simultaneous responses from the muscular and circulatory system occur in the driver's body under simulated conditions of a crash threat. The study was carried out in a passenger car driving simulator. The crash was included in the driving test scenario developed in an urban setting. In the group of 22 young male subjects, two physiological signals - ECG and EMG were continuously recorded. The length of the RR interval in the ECG signal was assessed. A HRV analysis was performed in the time and frequency domains for 1-minute record segments at rest (seated position), during undisturbed driving as well as during and several minutes after the crash. For the left and right side muscles: m. trapezius (TR) and m. flexor digitorum superficialis (FDS), the EMG signal amplitude was determined. The percentage of maximal voluntary contraction (MVC) was compared during driving and during the crash. As for the ECG signal, it was found that in most of the drivers changes occurred in the parameter values reflecting HRV in the time domain. Significant changes were noted in the mean length of RR intervals (mRR). As for the EMG signal, the changes in the amplitude concerned the signal recorded from the FDS muscle. The changes in ECG and EMG were simultaneous in half of the cases. Such parameters as mRR (ECG signal) and FDS-L amplitude (EMG signal) were the responses to accident risk. Under simulated conditions, responses from the circulatory and musculoskeletal systems are not always simultaneous. The results indicate that a more complete driver's response to a crash in road traffic is obtained based on parallel recording of two physiological signals (ECG and EMG).

  20. An RFID tag system-on-chip with wireless ECG monitoring for intelligent healthcare systems.

    PubMed

    Wang, Cheng-Pin; Lee, Shuenn-Yuh; Lai, Wei-Chih

    2013-01-01

    This paper presents a low-power wireless ECG acquisition system-on-chip (SoC), including an RF front-end circuit, a power unit, an analog front-end circuit, and a digital circuitry. The proposed RF front-end circuit can provide the amplitude shift keying demodulation and distance to digital conversion to accurately receive the data from the reader. The received data will wake up the power unit to provide the required supply voltages of analog front-end (AFE) and digital circuitry. The AFE, including a pre-amplifier, an analog filter, a post-amplifier, and an analog-to-digital converter, is used for the ECG acquisition. Moreover, the EPC Class I Gen 2 UHF standard is employed in the digital circuitry for the handshaking of communication and the control of the system. The proposed SoC has been implemented in 0.18-µm standard CMOS process and the measured results reveal the communication is compatible to the RFID protocol. The average power consumption for the operating chip is 12 µW. Using a Sony PR44 battery to the supply power (605mAh@1.4V), the RFID tag SoC operates continuously for about 50,000 hours (>5 years), which is appropriate for wireless wearable ECG monitoring systems.

  1. Off-site expert support for nurses undertaking ECGs in primary care.

    PubMed

    Weatherburn, Gwyn; Ward, Stephen; Johnston, Glenis; Chisholm, Sally

    One of the aims of the Department of Health is to respond to patient needs by considering how services can be delivered in more innovative ways, including more services being provided in primary care and increased activities being undertaken by nursing staff. These activities may have previously been undertaken by the GPs, or patients would be sent elsewhere, such as the local hospital, for tests/investigations. Some general practices are already using cardiac telemetry while others are awaiting feedback from system users before deciding whether to purchase services from independent providers. However, identifying how generalized results and predicted benefits will apply in a specific practice is not always straightforward. This article aims to assist the decision-making process by providing the results of an audit from eight general practices and two walk-in centres in which the electrocardiograms (ECGs) were already being undertaken by nurses. The results, which are shown for each centre, showed that the frequency of use varied between one and 27 per month, depending upon the practice. As a result of the 373 patients who had an ECG performed in practice, 76 had altered management decisions, 14 were saved hospital referral (11 of these from one walk-in centre), 18 were admitted to an acute hospital (10 from the same walk-in centre), and another 24 were referred to hospital for investigation.

  2. Human Characteristics and Measures in Systems Design

    DTIC Science & Technology

    2003-01-01

    Electrodermal Skin conductance Field/lab $ * activity and electrode response EKG/ECG Electrocardiogram ECG electrodes- Field/la:h $ * HR, HRV Heart rate...illumination, motion, etc.). It may also be caused by psychological pressures (e.g., anxiety , anger/hostility, the "fight or flight" syndrome, threat

  3. [Detection of Heart Rate of Fetal ECG Based on STFT and BSS].

    PubMed

    Wang, Xu; Cai, Kun

    2016-01-01

    Changes in heart rate of fetal is function regulating performance of the circulatory system and the central nervous system, it is significant to detect heart rate of fetus in perinatal fetal. This paper puts forward the fetal heart rate detection method based on short time Fourier transform and blind source separation. First of all, the mixed ECG signal was preprocessed, and then the wavelet transform technique was used to separate the fetal ECG signal with noise from mixed ECG signal, after that, the short-time Fourier transform and the blind separation were carried on it, and then calculated the correlation coefficient of it, Finally, An independent component that it has strongest correlation with the original signal was selected to make FECG peak detection and calculated the fetal instantaneous heart rate. The experimental results show that the method can improve the detection rate of the FECG peak (R), and it has high accuracy in fixing peak(R) location in the case of low signal-noise ratio.

  4. Analyzing Thorough QT Study 1 & 2 in the Telemetric and Holter ECG Warehouse (THEW) using Hannover ECG System HES : A validation study.

    PubMed

    Khawaja, A; Petrovic, R; Safer, A; Baas, T; Dössel, O; Fischer, R

    2010-01-01

    Following the ICH E14 clinical evaluation guideline [1], the measurement of QT/QTc interval prolongation has become the standard surrogate biomarker for cardiac drug safety assessment and the faith of a drug development. In Thorough QT (TQT) study, a so-called positive control is employed to assess the ability of this study to detect the endpoint of interest, i.e. the QT prolongation by about five milliseconds. In other words the lower bound of the one-sided 95% confidence interval (CI) must be above 0 [ms]. Fully automated detection of ECG fiducial points and measurement of the corresponding intervals including QT intervals and RR intervals vary between different computerized algorithms. In this work we demonstrate the ability and reliability of Hannover ECG System (HES(®)) to assess drug effects by detecting QT/QTc prolongation effects that meet the threshold of regulatory concern as mentioned by using THEW database studies namely TQT studies one and two.

  5. Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology.

    PubMed

    Singh, Om Prakash; Mekonnen, Dawit; Malarvili, M B

    2015-01-01

    This paper leads to developing a Labview based ECG patient monitoring system for cardiovascular patient using Simple Mail Transfer Protocol technology. The designed device has been divided into three parts. First part is ECG amplifier circuit, built using instrumentation amplifier (AD620) followed by signal conditioning circuit with the operation amplifier (lm741). Secondly, the DAQ card is used to convert the analog signal into digital form for the further process. Furthermore, the data has been processed in Labview where the digital filter techniques have been implemented to remove the noise from the acquired signal. After processing, the algorithm was developed to calculate the heart rate and to analyze the arrhythmia condition. Finally, SMTP technology has been added in our work to make device more communicative and much more cost-effective solution in telemedicine technology which has been key-problem to realize the telediagnosis and monitoring of ECG signals. The technology also can be easily implemented over already existing Internet.

  6. Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology

    PubMed Central

    Singh, Om Prakash; Mekonnen, Dawit; Malarvili, M. B.

    2015-01-01

    This paper leads to developing a Labview based ECG patient monitoring system for cardiovascular patient using Simple Mail Transfer Protocol technology. The designed device has been divided into three parts. First part is ECG amplifier circuit, built using instrumentation amplifier (AD620) followed by signal conditioning circuit with the operation amplifier (lm741). Secondly, the DAQ card is used to convert the analog signal into digital form for the further process. Furthermore, the data has been processed in Labview where the digital filter techniques have been implemented to remove the noise from the acquired signal. After processing, the algorithm was developed to calculate the heart rate and to analyze the arrhythmia condition. Finally, SMTP technology has been added in our work to make device more communicative and much more cost-effective solution in telemedicine technology which has been key-problem to realize the telediagnosis and monitoring of ECG signals. The technology also can be easily implemented over already existing Internet. PMID:27006940

  7. Closed-Loop Control of Humidification for Artifact Reduction in Capacitive ECG Measurements.

    PubMed

    Leicht, Lennart; Eilebrecht, Benjamin; Weyer, Soren; Leonhardt, Steffen; Teichmann, Daniel

    2017-04-01

    Recording biosignals without the need for direct skin contact offers new opportunities for ubiquitous health monitoring. Electrodes with capacitive coupling have been shown to be suitable for the monitoring of electrical potentials on the body surface, in particular ECG. However, due to triboelectric charge generation and motion artifacts, signal and thus diagnostic quality is inferior to galvanic coupling. Active closed-loop humidification of capacitive electrodes is proposed in this work as a new concept to improve signal quality. A capacitive ECG recording system integrated into a common car seat is presented. It can regulate the micro climate at the interface of electrode and patient by actively dispensing water vapour and monitoring humidity in a closed-loop approach. As a regenerative water reservoir, silica gel is used. The system was evaluated with respect to subjective and objective ECG signal quality. Active humidification was found to have a significant positive effect in case of previously poor quality. Also, it had no diminishing effect in case of already good signal quality.

  8. A PDA-based electrocardiogram/blood pressure telemonitor for telemedicine.

    PubMed

    Bolanos, Marcos; Nazeran, Homayoun; Gonzalez, Izzac; Parra, Ricardo; Martinez, Christopher

    2004-01-01

    An electrocardiogram (ECG) / blood pressure (BP) telemonitor consisting of comprehensive integration of various electrical engineering concepts, devices, and methods was developed. This personal digital assistant-based (PDAbased) system focused on integration of biopotential amplifiers, photoplethysmographic measurement of blood pressure, microcontroller devices, programming methods, wireless transmission, signal filtering and analysis, interfacing, and long term memory devices (24 hours) to develop a state-of-the-art ECG/BP telemonitor. These instrumentation modules were developed and tested to realize a complete and compact system that could be deployed to assist in telemedicine applications and heart rate variability studies. The specific objective of this device was to facilitate the long term monitoring and recording of ECG and blood pressure signals. This device was able to acquire ECG/BP waveforms, transmit them wirelessly to a PDA, save them onto a compact flash memory, and display them on the LCD screen of the PDA. It was also capable of calculating the heart rate (HR) in beats per minute, and providing systolic and diastolic blood pressure values.

  9. Continuous ECG Monitoring in Patients With Acute Coronary Syndrome or Heart Failure: EASI Versus Gold Standard.

    PubMed

    Lancia, Loreto; Toccaceli, Andrea; Petrucci, Cristina; Romano, Silvio; Penco, Maria

    2018-05-01

    The purpose of the study was to compare the EASI system with the standard 12-lead surface electrocardiogram (ECG) for the accuracy in detecting the main electrocardiographic parameters (J point, PR, QT, and QRS) commonly monitored in patients with acute coronary syndromes or heart failure. In this observational comparative study, 253 patients who were consecutively admitted to the coronary care unit with acute coronary syndrome or heart failure were evaluated. In all patients, two complete 12-lead ECGs were acquired simultaneously. A total of 6,072 electrocardiographic leads were compared (3,036 standard and 3,036 EASI). No significant differences were found between the investigate parameters of the two measurement methods, either in patients with acute coronary syndrome or in those with heart failure. This study confirmed the accuracy of the EASI system in monitoring the main ECG parameters in patients admitted to the coronary care unit with acute coronary syndrome or heart failure.

  10. Reconfigurable wearable to monitor physiological variables and movement

    NASA Astrophysics Data System (ADS)

    Romero, Francisco J.; Morales, Diego P.; Castillo, Encarnación; García, Antonio; Tahmassebi, Amirhessam; Meyer-Baese, Anke

    2017-05-01

    This article presents a preliminary prototype of a wearable instrument for oxygen saturation and ECG monitoring. The proposed measuring system is based on the light reflection variability of a LED emission on the subject temple. Besides, the system has the capacity to incorporate electrodes to obtain ECG measurements. All measurements are stored and transmitted to a mobile device (tablet or smartphone) through a Bluetooth link.

  11. Biosignal integrated circuit with simultaneous acquisition of ECG and PPG for wearable healthcare applications.

    PubMed

    Kim, Hyungseup; Park, Yunjong; Ko, Youngwoon; Mun, Yeongjin; Lee, Sangmin; Ko, Hyoungho

    2018-01-01

    Wearable healthcare systems require measurements from electrocardiograms (ECGs) and photoplethysmograms (PPGs), and the blood pressure of the user. The pulse transit time (PTT) can be calculated by measuring the ECG and PPG simultaneously. Continuous-time blood pressure without using an air cuff can be estimated by using the PTT. This paper presents a biosignal acquisition integrated circuit (IC) that can simultaneously measure the ECG and PPG for wearable healthcare applications. Included in this biosignal acquisition circuit are a voltage mode instrumentation amplifier (IA) for ECG acquisition and a current mode transimpedance amplifier for PPG acquisition. The analog outputs from the ECG and PPG channels are muxed and converted to digital signals using 12-bit successive approximation register (SAR) analog-to-digital converter (ADC). The proposed IC is fabricated by using a standard 0.18 μm CMOS process with an active area of 14.44 mm2. The total current consumption for the multichannel IC is 327 μA with a 3.3 V supply. The measured input referred noise of ECG readout channel is 1.3 μVRMS with a bandwidth of 0.5 Hz to 100 Hz. And the measured input referred current noise of the PPG readout channel is 0.122 nA/√Hz with a bandwidth of 0.5 Hz to 100 Hz. The proposed IC, which is implemented using various circuit techniques, can measure ECG and PPG signals simultaneously to calculate the PTT for wearable healthcare applications.

  12. Hybrid method based on singular value decomposition and embedded zero tree wavelet technique for ECG signal compression.

    PubMed

    Kumar, Ranjeet; Kumar, A; Singh, G K

    2016-06-01

    In the field of biomedical, it becomes necessary to reduce data quantity due to the limitation of storage in real-time ambulatory system and telemedicine system. Research has been underway since very beginning for the development of an efficient and simple technique for longer term benefits. This paper, presents an algorithm based on singular value decomposition (SVD), and embedded zero tree wavelet (EZW) techniques for ECG signal compression which deals with the huge data of ambulatory system. The proposed method utilizes the low rank matrix for initial compression on two dimensional (2-D) ECG data array using SVD, and then EZW is initiated for final compression. Initially, 2-D array construction has key issue for the proposed technique in pre-processing. Here, three different beat segmentation approaches have been exploited for 2-D array construction using segmented beat alignment with exploitation of beat correlation. The proposed algorithm has been tested on MIT-BIH arrhythmia record, and it was found that it is very efficient in compression of different types of ECG signal with lower signal distortion based on different fidelity assessments. The evaluation results illustrate that the proposed algorithm has achieved the compression ratio of 24.25:1 with excellent quality of signal reconstruction in terms of percentage-root-mean square difference (PRD) as 1.89% for ECG signal Rec. 100 and consumes only 162bps data instead of 3960bps uncompressed data. The proposed method is efficient and flexible with different types of ECG signal for compression, and controls quality of reconstruction. Simulated results are clearly illustrate the proposed method can play a big role to save the memory space of health data centres as well as save the bandwidth in telemedicine based healthcare systems. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Implementation of a WAP-based telemedicine system for patient monitoring.

    PubMed

    Hung, Kevin; Zhang, Yuan-Ting

    2003-06-01

    Many parties have already demonstrated telemedicine applications that use cellular phones and the Internet. A current trend in telecommunication is the convergence of wireless communication and computer network technologies, and the emergence of wireless application protocol (WAP) devices is an example. Since WAP will also be a common feature found in future mobile communication devices, it is worthwhile to investigate its use in telemedicine. This paper describes the implementation and experiences with a WAP-based telemedicine system for patient-monitoring that has been developed in our laboratory. It utilizes WAP devices as mobile access terminals for general inquiry and patient-monitoring services. Authorized users can browse the patients' general data, monitored blood pressure (BP), and electrocardiogram (ECG) on WAP devices in store-and-forward mode. The applications, written in wireless markup language (WML), WMLScript, and Perl, resided in a content server. A MySQL relational database system was set up to store the BP readings, ECG data, patient records, clinic and hospital information, and doctors' appointments with patients. A wireless ECG subsystem was built for recording ambulatory ECG in an indoor environment and for storing ECG data into the database. For testing, a WAP phone compliant with WAP 1.1 was used at GSM 1800 MHz by circuit-switched data (CSD) to connect to the content server through a WAP gateway, which was provided by a mobile phone service provider in Hong Kong. Data were successfully retrieved from the database and displayed on the WAP phone. The system shows how WAP can be feasible in remote patient-monitoring and patient data retrieval.

  14. Atrial Fibrillation Screening in Nonmetropolitan Areas Using a Telehealth Surveillance System With an Embedded Cloud-Computing Algorithm: Prospective Pilot Study.

    PubMed

    Chen, Ying-Hsien; Hung, Chi-Sheng; Huang, Ching-Chang; Hung, Yu-Chien; Hwang, Juey-Jen; Ho, Yi-Lwun

    2017-09-26

    Atrial fibrillation (AF) is a common form of arrhythmia that is associated with increased risk of stroke and mortality. Detecting AF before the first complication occurs is a recognized priority. No previous studies have examined the feasibility of undertaking AF screening using a telehealth surveillance system with an embedded cloud-computing algorithm; we address this issue in this study. The objective of this study was to evaluate the feasibility of AF screening in nonmetropolitan areas using a telehealth surveillance system with an embedded cloud-computing algorithm. We conducted a prospective AF screening study in a nonmetropolitan area using a single-lead electrocardiogram (ECG) recorder. All ECG measurements were reviewed on the telehealth surveillance system and interpreted by the cloud-computing algorithm and a cardiologist. The process of AF screening was evaluated with a satisfaction questionnaire. Between March 11, 2016 and August 31, 2016, 967 ECGs were recorded from 922 residents in nonmetropolitan areas. A total of 22 (2.4%, 22/922) residents with AF were identified by the physician's ECG interpretation, and only 0.2% (2/967) of ECGs contained significant artifacts. The novel cloud-computing algorithm for AF detection had a sensitivity of 95.5% (95% CI 77.2%-99.9%) and specificity of 97.7% (95% CI 96.5%-98.5%). The overall satisfaction score for the process of AF screening was 92.1%. AF screening in nonmetropolitan areas using a telehealth surveillance system with an embedded cloud-computing algorithm is feasible. ©Ying-Hsien Chen, Chi-Sheng Hung, Ching-Chang Huang, Yu-Chien Hung, Juey-Jen Hwang, Yi-Lwun Ho. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 26.09.2017.

  15. An ultra-low power (ULP) bandage-type ECG sensor for efficient cardiac disease management.

    PubMed

    Shin, Kunsoo; Park, G G; Kim, J P; Lee, T H; Ko, B H; Kim, Y H

    2013-01-01

    This paper proposed an ultra-low power bandage-type ECG sensor (the size: 76 × 34 × 3 (mm(3)) and the power consumption: 1 mW) which allows for a continuous and real-time monitoring of a user's ECG signals over 24h during daily activities. For its compact size and lower power consumption, we designed the analog front-end, the SRP (Samsung Reconfigurable Processor) based DSP of 30 uW/MHz, and the ULP wireless RF of 1 nJ/bit. Also, to tackle motion artifacts(MA), a MA monitoring technique based on the HCP (Half-cell Potential) is proposed which resulted in the high correlation between the MA and the HCP, the correlation coefficient of 0.75 ± 0.18. To assess its feasibility and validity as a wearable health monitor, we performed the comparison of two ECG signals recorded form it and a conventional Holter device. As a result, the performance of the former is a little lower as compared with the latter, although showing no statistical significant difference (the quality of the signal: 94.3% vs 99.4%; the accuracy of arrhythmia detection: 93.7% vs 98.7%). With those results, it has been confirmed that it can be used as a wearable health monitor due to its comfortability, its long operation lifetime and the good quality of the measured ECG signal.

  16. System light-loading technology for mHealth: Manifold-learning-based medical data cleansing and clinical trials in WE-CARE Project.

    PubMed

    Huang, Anpeng; Xu, Wenyao; Li, Zhinan; Xie, Linzhen; Sarrafzadeh, Majid; Li, Xiaoming; Cong, Jason

    2014-09-01

    Cardiovascular disease (CVD) is a major issue to public health. It contributes 41% to the Chinese death rate each year. This huge loss encouraged us to develop a Wearable Efficient teleCARdiology systEm (WE-CARE) for early warning and prevention of CVD risks in real time. WE-CARE is expected to work 24/7 online for mobile health (mHealth) applications. Unfortunately, this purpose is often disrupted in system experiments and clinical trials, even if related enabling technologies work properly. This phenomenon is rooted in the overload issue of complex Electrocardiogram (ECG) data in terms of system integration. In this study, our main objective is to get a system light-loading technology to enable mHealth with a benchmarked ECG anomaly recognition rate. To achieve this objective, we propose an approach to purify clinical features from ECG raw data based on manifold learning, called the Manifold-based ECG-feature Purification algorithm. Our clinical trials verify that our proposal can detect anomalies with a recognition rate of up to 94% which is highly valuable in daily public health-risk alert applications based on clinical criteria. Most importantly, the experiment results demonstrate that the WE-CARE system enabled by our proposal can enhance system reliability by at least two times and reduce false negative rates to 0.76%, and extend the battery life by 40.54%, in the system integration level.

  17. Epileptic seizure onset detection based on EEG and ECG data fusion.

    PubMed

    Qaraqe, Marwa; Ismail, Muhammad; Serpedin, Erchin; Zulfi, Haneef

    2016-05-01

    This paper presents a novel method for seizure onset detection using fused information extracted from multichannel electroencephalogram (EEG) and single-channel electrocardiogram (ECG). In existing seizure detectors, the analysis of the nonlinear and nonstationary ECG signal is limited to the time-domain or frequency-domain. In this work, heart rate variability (HRV) extracted from ECG is analyzed using a Matching-Pursuit (MP) and Wigner-Ville Distribution (WVD) algorithm in order to effectively extract meaningful HRV features representative of seizure and nonseizure states. The EEG analysis relies on a common spatial pattern (CSP) based feature enhancement stage that enables better discrimination between seizure and nonseizure features. The EEG-based detector uses logical operators to pool SVM seizure onset detections made independently across different EEG spectral bands. Two fusion systems are adopted. In the first system, EEG-based and ECG-based decisions are directly fused to obtain a final decision. The second fusion system adopts an override option that allows for the EEG-based decision to override the fusion-based decision in the event that the detector observes a string of EEG-based seizure decisions. The proposed detectors exhibit an improved performance, with respect to sensitivity and detection latency, compared with the state-of-the-art detectors. Experimental results demonstrate that the second detector achieves a sensitivity of 100%, detection latency of 2.6s, and a specificity of 99.91% for the MAJ fusion case. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Seismocardiography-Based Cardiac Computed Tomography Gating Using Patient-Specific Template Identification and Detection.

    PubMed

    Yao, Jingting; Tridandapani, Srini; Wick, Carson A; Bhatti, Pamela T

    2017-01-01

    To more accurately trigger cardiac computed tomography angiography (CTA) than electrocardiography (ECG) alone, a sub-system is proposed as an intermediate step toward fusing ECG with seismocardiography (SCG). Accurate prediction of quiescent phases is crucial to prospectively gating CTA, which is susceptible to cardiac motion and, thus, can affect the diagnostic quality of images. The key innovation of this sub-system is that it identifies the SCG waveform corresponding to heart sounds and determines their phases within the cardiac cycles. Furthermore, this relationship is modeled as a linear function with respect to heart rate. For this paper, B-mode echocardiography is used as the gold standard for identifying the quiescent phases. We analyzed synchronous ECG, SCG, and echocardiography data acquired from seven healthy subjects (mean age: 31; age range: 22-48; males: 4) and 11 cardiac patients (mean age: 56; age range: 31-78; males: 6). On average, the proposed algorithm was able to successfully identify 79% of the SCG waveforms in systole and 68% in diastole. The simulated results show that SCG-based prediction produced less average phase error than that of ECG. It was found that the accuracy of ECG-based gating is more susceptible to increases in heart rate variability, while SCG-based gating is susceptible to high cycle to cycle variability in morphology. This pilot work of prediction using SCG waveforms enriches the framework of a comprehensive system with multiple modalities that could potentially, in real time, improve the image quality of CTA.

  19. Sticker-type ECG/PPG concurrent monitoring system hybrid integration of CMOS SoC and organic sensor device.

    PubMed

    Yongsu Lee; Hyeonwoo Lee; Seunghyup Yoo; Hoi-Jun Yoo

    2016-08-01

    The sticker-type sensor system is proposed targeting ECG/PPG concurrent monitoring for cardiovascular diseases. The stickers are composed of two types: Hub and Sensor-node (SN) sticker. Low-power CMOS SoC for measuring ECG and PPG signal is hybrid integrated with organic light emitting diodes (OLEDs) and organic photo detector (OPD). The sticker has only 2g weight and only consumes 141μW. The optical calibration loop is adopted for maintaining SNR of PPG signal higher than 30dB. The pulse arrival time (PAT) and SpO2 value can be extracted from various body parts and verified comparing with the reference device from 20 people in-vivo experiments.

  20. Deployment of an Advanced Electrocardiographic Analysis (A-ECG) to Detect Cardiovascular Risk in Career Firefighters

    NASA Technical Reports Server (NTRS)

    Dolezal, B. A.; Storer, T. W.; Abrazado, M.; Watne, R.; Schlegel, T. T.; Batalin, M.; Kaiser, W.; Smith, D. L.; Cooper, C. B.

    2011-01-01

    INTRODUCTION: Sudden cardiac death is the leading cause of line of duty death among firefighters, accounting for approximately 45% of fatalities annually. Firefighters perform strenuous muscular work while wearing heavy, encapsulating personal protective equipment in high ambient temperatures, under chaotic and emotionally stressful conditions. These factors can precipitate sudden cardiac events like myocardial infarction, serious dysrhythmias, or cerebrovascular accidents in firefighters with underlying cardiovascular disease. PURPOSE: The purpose of this study was to deploy and then evaluate the contribution of resting advanced ECG (A-ECG) in addition to other screening tools (family history, lipid profiles, and cardiopulmonary exercise tests, XT) in assessment of an individual fs cardiac risk profile. METHODS: Forty-four career firefighters were recruited to perform comprehensive baseline assessments including tests of aerobic performance, fasting lipids and glucose. Five-min resting 12-lead A-ECGs were obtained in a subset of firefighters (n=21) and transmitted over a secure networked system to a NASA physician collaborator. Using myocardial perfusion and other imaging as the gold standard, A-ECG scoring has been proven useful in accurately identifying a number of cardiac pathologies including coronary artery disease (CAD), left ventricular hypertrophy, hypertrophic cardiomyopathy, and non-ischemic and ischemic cardiomyopathy. RESULTS: Subjects f mean (SD) age was 43 (8) years, weight 91 (13) kg, and BMI 28 (3) kg/m2. Fifty-one percent of subjects had .3 cardiovascular risk factors. One subject had ST depression on XT ECG, at least one positive A-ECG score for CAD, and documented CAD based on cardiology referral. While all other subjects, including those with fewer risk factors, higher aerobic fitness, and normal exercise ECGs, were classified as healthy by A-ECG, there was no trend for association between risk factors and any of 20 A-ECG parameters in the grouped data.

  1. Combined Electrocardiography- and Respiratory-Triggered CT of the Lung to Reduce Respiratory Misregistration Artifacts between Imaging Slabs in Free-Breathing Children: Initial Experience.

    PubMed

    Goo, Hyun Woo; Allmendinger, Thomas

    2017-01-01

    Cardiac and respiratory motion artifacts degrade the image quality of lung CT in free-breathing children. The aim of this study was to evaluate the effect of combined electrocardiography (ECG) and respiratory triggering on respiratory misregistration artifacts on lung CT in free-breathing children. In total, 15 children (median age 19 months, range 6 months-8 years; 7 boys), who underwent free-breathing ECG-triggered lung CT with and without respiratory-triggering were included. A pressure-sensing belt of a respiratory gating system was used to obtain the respiratory signal. The degree of respiratory misregistration artifacts between imaging slabs was graded on a 4-point scale (1, excellent image quality) on coronal and sagittal images and compared between ECG-triggered lung CT studies with and without respiratory triggering. A p value < 0.05 was considered significant. Lung CT with combined ECG and respiratory triggering showed significantly less respiratory misregistration artifacts than lung CT with ECG triggering only (1.1 ± 0.4 vs. 2.2 ± 1.0, p = 0.003). Additional respiratory-triggering reduces respiratory misregistration artifacts on ECG-triggered lung CT in free-breathing children.

  2. Mobile cloud-computing-based healthcare service by noncontact ECG monitoring.

    PubMed

    Fong, Ee-May; Chung, Wan-Young

    2013-12-02

    Noncontact electrocardiogram (ECG) measurement technique has gained popularity these days owing to its noninvasive features and convenience in daily life use. This paper presents mobile cloud computing for a healthcare system where a noncontact ECG measurement method is employed to capture biomedical signals from users. Healthcare service is provided to continuously collect biomedical signals from multiple locations. To observe and analyze the ECG signals in real time, a mobile device is used as a mobile monitoring terminal. In addition, a personalized healthcare assistant is installed on the mobile device; several healthcare features such as health status summaries, medication QR code scanning, and reminders are integrated into the mobile application. Health data are being synchronized into the healthcare cloud computing service (Web server system and Web server dataset) to ensure a seamless healthcare monitoring system and anytime and anywhere coverage of network connection is available. Together with a Web page application, medical data are easily accessed by medical professionals or family members. Web page performance evaluation was conducted to ensure minimal Web server latency. The system demonstrates better availability of off-site and up-to-the-minute patient data, which can help detect health problems early and keep elderly patients out of the emergency room, thus providing a better and more comprehensive healthcare cloud computing service.

  3. Mobile Cloud-Computing-Based Healthcare Service by Noncontact ECG Monitoring

    PubMed Central

    Fong, Ee-May; Chung, Wan-Young

    2013-01-01

    Noncontact electrocardiogram (ECG) measurement technique has gained popularity these days owing to its noninvasive features and convenience in daily life use. This paper presents mobile cloud computing for a healthcare system where a noncontact ECG measurement method is employed to capture biomedical signals from users. Healthcare service is provided to continuously collect biomedical signals from multiple locations. To observe and analyze the ECG signals in real time, a mobile device is used as a mobile monitoring terminal. In addition, a personalized healthcare assistant is installed on the mobile device; several healthcare features such as health status summaries, medication QR code scanning, and reminders are integrated into the mobile application. Health data are being synchronized into the healthcare cloud computing service (Web server system and Web server dataset) to ensure a seamless healthcare monitoring system and anytime and anywhere coverage of network connection is available. Together with a Web page application, medical data are easily accessed by medical professionals or family members. Web page performance evaluation was conducted to ensure minimal Web server latency. The system demonstrates better availability of off-site and up-to-the-minute patient data, which can help detect health problems early and keep elderly patients out of the emergency room, thus providing a better and more comprehensive healthcare cloud computing service. PMID:24316562

  4. Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; Kulecz, Walter B.; DePalma, Jude L.; Feiveson, Alan H.; Wilson, John S.; Rahman, M. Atiar; Bungo, Michael W.

    2004-01-01

    Several studies have shown that diminution of the high-frequency (HF; 150-250 Hz) components present within the central portion of the QRS complex of an electrocardiogram (ECG) is a more sensitive indicator for the presence of myocardial ischemia than are changes in the ST segments of the conventional low-frequency ECG. However, until now, no device has been capable of displaying, in real time on a beat-to-beat basis, changes in these HF QRS ECG components in a continuously monitored patient. Although several software programs have been designed to acquire the HF components over the entire QRS interval, such programs have involved laborious off-line calculations and postprocessing, limiting their clinical utility. We describe a personal computer-based ECG software program developed recently at the National Aeronautics and Space Administration (NASA) that acquires, analyzes, and displays HF QRS components in each of the 12 conventional ECG leads in real time. The system also updates these signals and their related derived parameters in real time on a beat-to-beat basis for any chosen monitoring period and simultaneously displays the diagnostic information from the conventional (low-frequency) 12-lead ECG. The real-time NASA HF QRS ECG software is being evaluated currently in multiple clinical settings in North America. We describe its potential usefulness in the diagnosis of myocardial ischemia and coronary artery disease.

  5. Adaptive noise canceling of electrocardiogram artifacts in single channel electroencephalogram.

    PubMed

    Cho, Sung Pil; Song, Mi Hye; Park, Young Cheol; Choi, Ho Seon; Lee, Kyoung Joung

    2007-01-01

    A new method for estimating and eliminating electrocardiogram (ECG) artifacts from single channel scalp electroencephalogram (EEG) is proposed. The proposed method consists of emphasis of QRS complex from EEG using least squares acceleration (LSA) filter, generation of synchronized pulse with R-peak and ECG artifacts estimation and elimination using adaptive filter. The performance of the proposed method was evaluated using simulated and real EEG recordings, we found that the ECG artifacts were successfully estimated and eliminated in comparison with the conventional multi-channel techniques, which are independent component analysis (ICA) and ensemble average (EA) method. From this we can conclude that the proposed method is useful for the detecting and eliminating the ECG artifacts from single channel EEG and simple to use for ambulatory/portable EEG monitoring system.

  6. A reconfigurable, wearable, wireless ECG system.

    PubMed

    Borromeo, S; Rodriguez-Sanchez, C; Machado, F; Hernandez-Tamames, J A; de la Prieta, R

    2007-01-01

    New emerging concepts as "wireless hospital", "mobile healthcare" or "wearable telemonitoring" require the development of bio-signal acquisition devices to be easily integrated into the clinical routine. In this work, we present a new system for Electrocardiogram (ECG) acquisition and its processing, with wireless transmission on demand (either the complete ECG or only one alarm message, just in case a pathological heart rate detected). Size and power consumption are optimized in order to provide mobility and comfort to the patient. We have designed a modular hardware system and an autonomous platform based on a Field-Programmable Gate Array (FPGA) for developing and debugging. The modular approach allows to redesign the system in an easy way. Its adaptation to a new biomedical signal would only need small changes on it. The hardware system is composed of three layers that can be plugged/unplugged: communication layer, processing layer and sensor layer. In addition, we also present a general purpose end-user application developed for mobile phones or Personal Digital Assistant devices (PDAs).

  7. Clinical and electrocardiographic presentations of transient trifascicular block in three cats.

    PubMed

    Oxford, Eva M; Giacomazzi, Flavia B; Moïse, N Sydney; Santilli, Roberto A

    2018-06-01

    This report describes transient trifascicular block in three cats presented with lethargy and inappetence, and elevated cardiac troponin I concentrations. The electrocardiogram (ECG) of cat 1 showed a sinus rhythm with pronounced first-degree atrioventricular (AV) block, right bundle branch block, and left anterior fascicular block. The ECG of cat 2 showed truncular left bundle branch block alternating with left anterior fascicular block coupled with prolonged PR intervals, second-degree heart block, and paroxysmal third-degree AV block. The ECG of cat 3 showed first-degree AV block with concomitant right bundle branch block. The diagnosis of trifascicular block was made when paroxysmal third-degree AV block was documented. All cats recovered with medical management within weeks. Each cat resumed a sinus rhythm. Elevated cardiac troponin I concentrations suggested myocarditis that improved. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Is there evidence for mandating electrocardiogram as part of the pre-participation examination?

    PubMed

    Borjesson, Mats; Dellborg, Mikael

    2011-01-01

    The risk of sudden cardiac death may be increased up to 2.8 times in competitive athletes compared with nonathletes. The majority of sudden cardiac death cases are caused by an underlying abnormality that potentially may be identified on cardiovascular screening, depending on the specific abnormality and the content of the cardiovascular screening applied. Indeed, today, cardiac screening is universally recommended by the cardiac societies [European Society of Cardiology (ESC) and American Heart Association (AHA)] and required by the sporting bodies [Fédération Internationale de Football Association (FIFA) and Union of European Football Associations (UEFA)]. Pre-participation examination is by consensus understood to include personal history and physical examination; controversy exists regarding the usefulness and appropriateness of screening using resting 12-lead electrocardiogram (ECG), with an apparent transatlantic difference. The ESC recommends screening consisting of personal history, physical examination, and 12-lead resting ECG, whereas recommendations from the AHA includes only personal history and physical examination. There is firm scientific ground to state that the sensitivity of screening with ECG is vastly superior to, and the cost-effectiveness significantly better than, screening without ECG. Cardiac screening of elite athletes with personal history, physical examination, and ECG is cost-effective also in comparison with other well-accepted procedures of modern health care, such as dialysis and implantable cardiac defibrillators. Newly published recommendations for the interpretation of the ECG in athletes (ESC) and future studies on ECGs in athletes of different ethnicity, gender, and age may further increase the specificity of ECG in cardiac screening, refining the screening procedure and lowering the costs for additional follow-up testing. Cardiac screening without ECG is not cost-effective and may be only marginally better than no screening at all and at a considerable higher cost. The difficulties in feasibility and liability issues for recommending ECGs in some countries need to be acknowledged but must be dealt with within those countries/systems. On ethical grounds, the reasons (logistical, legal, economic) for not screening individual athletes should be clearly stated. Alas, the current evidence, as presented here, suggests that the ECG should be mandatory in pre-participation screening of athletes.

  9. Editor's Choice-Is the pre-hospital ECG after out-of-hospital cardiac arrest accurate for the diagnosis of ST-elevation myocardial infarction?

    PubMed

    Salam, Idrees; Hassager, Christian; Thomsen, Jakob Hartvig; Langkjær, Sandra; Søholm, Helle; Bro-Jeppesen, John; Bang, Lia; Holmvang, Lene; Erlinge, David; Wanscher, Michael; Lippert, Freddy K; Køber, Lars; Kjaergaard, Jesper

    2016-08-01

    Current guidelines recommend that comatose out-of-hospital cardiac arrest patients with ST-segment elevations (STEs) following return of spontaneous circulation (ROSC) should be referred for an acute coronary angiography. We sought to investigate the diagnostic value of the pre-hospital ROSC-ECG in predicting ST-elevation myocardial infarction (STEMI). ROSC-ECGs of 145 comatose survivors of out-of-hospital cardiac arrest, randomly assigned in the Target Temperature Management trial, were classified according to the current STEMI ECG criteria (third universal definition of myocardial infarction). STEs were present in the pre-hospital ROSC-ECG of 78 (54%) patients. A final diagnosis revealed that 69 (48%) patients had STEMI, 31 (21%) patients had non-STEMI and 45 (31%) patients had no myocardial infarction. STE in ROSC-ECGs had a sensitivity of 74% (95% confidence interval (CI) 62-84), specificity of 65% (95% CI 53-75) and a positive and negative predictive value of 65% (95% CI 54-76) and 73% (95% CI 61-83) in predicting STEMI. Time to ROSC was significantly longer (24 minutes vs. 19 minutes, P=0.02) in STE compared with no STE patients. Percutaneous coronary intervention was successful in 68% versus 36% (P<0.001) of STE compared to no STE patients. No significant difference was found in 180-day mortality rates between STE and no STE patients (36% vs. 30%, Plogrank=0.37). The pre-hospital ROSC-ECG is a suboptimal diagnostic tool to predict STEMI and therefore not a sensitive tool for triage to cardiac centres. This supports the incentive of referring all comatose survivors of out-of-hospital cardiac arrest of suspected cardiac origin to a tertiary heart centre with the availability of acute coronary angiography, even in the absence of STEs. © The European Society of Cardiology 2015.

  10. Electrocardiographic Indicators of Acute Coronary Syndrome are More Common in Patients with Ambulance Transport Compared to Those who Self-Transport to the Emergency Department Journal of Electrocardiology

    PubMed Central

    Pickham, David; Pelter, Michele M

    2016-01-01

    Introduction The American Heart Association recommends individuals with symptoms suggestive of acute coronary syndrome (ACS) activate the Emergency Medical Services’ (EMS) 911 system for ambulance transport to the emergency department (ED), which enables treatment to begin prior to hospital arrival. Despite this recommendation, the majority of patients with symptoms suspicious of ACS continue to self-transport to the ED. The IMMEDIATE AIM study was a prospective study that enrolled individuals who presented to the ED with ischemic symptoms. Objectives The purpose of this secondary analysis was to determine differences in patients presenting the ED for possible ACS who arrive by ambulance versus self-transport on: 1) Time-to-initial hospital electrocardiogram (ECG), 2) presence of ischemic ECG changes, and 3) patient characteristics. Methods Initial 12-lead ECGs acquired upon patient arrival to the ED were evaluated for ST-elevation, ST-depression, and T-wave inversion. ECG signs of ischemia were analyzed both individually and collapsed into an independent dichotomous variable (ED ECG ischemia yes/no) for statistical analysis. Patient characteristics tested included: gender, age, race, ethnicity, English speaking, living alone, mode of transport, and presenting symptoms (chest pain, jaw pain, shortness of breath, nausea/vomiting, syncope, and clinical history). Results In 1299 patients (mean age 63.9, 46.7% male), 384 (29.6%) patients arrived by ambulance to the ED. The mean time-to-initial ECG was 47 minutes for ambulance patients versus 53 minutes for self-transport patients (p<0.001). Mode of transport was found to be an independent predictor for time-to-initial ECG controlling for age, gender, and race (p=0.004). There were significantly higher rates of ECG changes of ischemia for patients who arrived by ambulance versus self-transport (p=0.02), and patient characteristics differed by mode of transport to the ED. Discussion Our findings indicate that less than 30% of individuals with symptoms of ACS activate the EMS ‘911’ system for ambulance transport to the ED. Individuals more likely to activate 911 have timelier ECG but higher rates of ischemic changes, specifically ST-depression and T-wave inversion. Individuals least likely to activate 911 are women, younger individuals, Latino ethnicity, live with a significant other, and those experiencing chest or jaw pain. PMID:27614946

  11. Noise Maps for Quantitative and Clinical Severity Towards Long-Term ECG Monitoring.

    PubMed

    Everss-Villalba, Estrella; Melgarejo-Meseguer, Francisco Manuel; Blanco-Velasco, Manuel; Gimeno-Blanes, Francisco Javier; Sala-Pla, Salvador; Rojo-Álvarez, José Luis; García-Alberola, Arcadi

    2017-10-25

    Noise and artifacts are inherent contaminating components and are particularly present in Holter electrocardiogram (ECG) monitoring. The presence of noise is even more significant in long-term monitoring (LTM) recordings, as these are collected for several days in patients following their daily activities; hence, strong artifact components can temporarily impair the clinical measurements from the LTM recordings. Traditionally, the noise presence has been dealt with as a problem of non-desirable component removal by means of several quantitative signal metrics such as the signal-to-noise ratio (SNR), but current systems do not provide any information about the true impact of noise on the ECG clinical evaluation. As a first step towards an alternative to classical approaches, this work assesses the ECG quality under the assumption that an ECG has good quality when it is clinically interpretable. Therefore, our hypotheses are that it is possible (a) to create a clinical severity score for the effect of the noise on the ECG, (b) to characterize its consistency in terms of its temporal and statistical distribution, and (c) to use it for signal quality evaluation in LTM scenarios. For this purpose, a database of external event recorder (EER) signals is assembled and labeled from a clinical point of view for its use as the gold standard of noise severity categorization. These devices are assumed to capture those signal segments more prone to be corrupted with noise during long-term periods. Then, the ECG noise is characterized through the comparison of these clinical severity criteria with conventional quantitative metrics taken from traditional noise-removal approaches, and noise maps are proposed as a novel representation tool to achieve this comparison. Our results showed that neither of the benchmarked quantitative noise measurement criteria represent an accurate enough estimation of the clinical severity of the noise. A case study of long-term ECG is reported, showing the statistical and temporal correspondences and properties with respect to EER signals used to create the gold standard for clinical noise. The proposed noise maps, together with the statistical consistency of the characterization of the noise clinical severity, paves the way towards forthcoming systems providing us with noise maps of the noise clinical severity, allowing the user to process different ECG segments with different techniques and in terms of different measured clinical parameters.

  12. Data management in automated external defibrillators: a call for a standardised solution.

    PubMed

    Nielsen, A M; Rasmussen, L S

    2011-07-01

    The ECG data stored in automated external defibrillators (AEDs) may be valuable for establishing a final diagnosis and deciding further diagnostics and treatment. Different data management systems are used and this may create significant problems for data storage and access for physicians treating victims in whom an AED has been used. In this descriptive study, we collected information (number, manufacturer and model) on 17 December 2010 from a web page used for the voluntary registration of AEDs in Denmark. The manufacturers were contacted and asked to provide information about data downloading. There were 12 different manufactures and 20 different AED models. Five models were registered in a quantity <5. We report data from the remaining 15 models (3603 AEDs). Several models stored only one case or 15 min of ECG data. All models had a data transfer option, but most had outdated 'hardware': Seven had infrared transfer; one had a cable with a serial port. Four had a removable memory device, but only one was a USB. The software was available as freeware only in a few cases. Otherwise, a CD ROM was needed, some even with a licence. The software for the second most common AED could not be installed. The development of data management solutions is not a high priority. We encourage the manufacturers to collaborate with researchers to develop a simple data transfer solution in order to improve patient care and facilitate research. © 2011 The Authors. Acta Anaesthesiologica Scandinavica © 2011 The Acta Anaesthesiologica Scandinavica Foundation.

  13. Use of echocardiography in outpatients with chest pain and normal resting electrocardiograms referred to Mayo Clinic Rochester.

    PubMed

    Gibbons, Raymond J; Carryer, Damita; Liu, Hongfang; Brady, Peter A; Askew, John Wells; Hodge, David; Ammash, Naser; Ebbert, Jon O; Roger, Veronique L

    2018-02-01

    To determine how often unnecessary resting echocardiograms that are "not recommended" by clinical practice guidelines are performed in patients with stable chest pain and normal resting electrocardiograms (ECGs). There are scant data to indicate how often Class III recommendations are ignored in clinical practice. We searched electronically all medical records of referral outpatients seen at Mayo Clinic Rochester from January 1, 2010, through December 31, 2013, to identify patients with stable chest pain and known or suspected coronary artery disease who underwent resting echocardiography and had normal resting ECGs and no other indication for echocardiography. Of the 15,529 referral outpatients who were evaluated at Mayo Clinic Rochester with chest pain, 3976 (25.6%) had resting echocardiograms. Eight hundred seventy of these 3976 patients (21.9%) had normal resting ECGs. Six hundred nineteen of these 870 patients (71.1%) had other indications for echocardiography. The remaining 251 patients (6.3% of all echocardiograms and 1.6% of all patients) had normal resting ECGs and no other indication for echocardiography. Two hundred thirty-nine of these 251 patients (95.2%) had normal echocardiograms. Of the 12 abnormal echocardiograms, only 4 led to any change in clinical management. Sixty-one of these 251 echocardiograms (24.3%) were "preordered" before the provider (physicians, nurses, physician assistants) visit. Echocardiograms were performed in 1 in 4 referral outpatients with chest pain seen at Mayo Clinic Rochester. However, only 1 in 16 of these echocardiograms was performed in violation of the class III recommendation in the American College of Cardiology Foundation/American Heart Association guidelines for the management of stable angina. These unnecessary echocardiograms were almost always normal, and had little impact on clinical management. The rate of unnecessary echocardiograms could be decreased by eliminating preordering. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Wolff-Parkinson-White Syndrome Mimics a Conduction Disease

    PubMed Central

    Marrakchi, S.; Kammoun, I.; Kachboura, S.

    2014-01-01

    Background. It is important to recognise Wolff-Parkinson-White (WPW) syndrome in electrocardiograms (ECG), as it may mimic ischaemic heart disease, ventricular hypertrophy, and bundle branch block. Recognising WPW syndrome allows for risk stratification, the identification of associated conditions, and the institution of appropriate management. Objective. The present case showed that electrophysiological study is indicated in patients with abnormal ECG and syncope. Case Report. A 40-year-old man with Wolff-Parkinson-White syndrome was presented to emergency with syncope. A baseline ECG was a complete right branch block and posterior left hemiblock. He was admitted to the cardiac care unit for pacemaker implantation. The atypical figure of complete right branch block and posterior left hemiblock was thought to be a “false positive” of conduction abnormality. But the long anterograde refractory period of the both accessory pathway and atrioventricular conduction may cause difficulty in diagnosing Wolff-Parkinson-White syndrome, Conclusion. A Wolff-Parkinson-White Syndrome may mimic a conduction disease. No reliable algorithm exists for making an ECG diagnosis of a preexcitation syndrome with conduction disorders. This can lead to diagnostic and therapeutic dilemmas in the context of syncope. PMID:25114686

  15. False Positive Stress Testing: Does Endothelial Vascular Dysfunction Contribute to ST-Segment Depression in Women? A Pilot Study.

    PubMed

    Sharma, Shilpa; Mehta, Puja K; Arsanjani, Reza; Sedlak, Tara; Hobel, Zachary; Shufelt, Chrisandra; Jones, Erika; Kligfield, Paul; Mortara, David; Laks, Michael; Diniz, Marcio; Bairey Merz, C Noel

    2018-06-19

    The utility of exercise-induced ST-segment depression for diagnosing ischemic heart disease (IHD) in women is unclear. Based on evidence that IHD pathophysiology in women involves coronary vascular dysfunction, we hypothesized that coronary vascular dysfunction contributes to exercise electrocardiography (Ex-ECG) ST-depression in the absence of obstructive CAD, so-called "false positive" results. We tested our hypothesis in a pilot study evaluating the relationship between peripheral vascular endothelial function and Ex-ECG. Twenty-nine asymptomatic women without cardiac risk factors underwent maximal Bruce protocol exercise treadmill testing and peripheral endothelial function assessment using peripheral arterial tonometry (Itamar EndoPAT 2000) to measure reactive hyperemia index (RHI). The relationship between RHI and Ex-ECG ST-segment depression was evaluated using logistic regression and differences in subgroups using two-tailed t-tests. Mean age was 54 ± 7 years, body mass index 25 ± 4 kg/m 2 , and RHI 2.51 ± 0.66. Three women (10%) had RHI less than 1.68, consistent with abnormal peripheral endothelial function, while 18 women (62%) met criteria for a positive Ex-ECG based on ST-segment depression in contiguous leads. Women with and without ST-segment depression had similar baseline and exercise vital signs, metabolic equivalents (METS) achieved, and RHI (all p>0.05). RHI did not predict ST-segment depression. Our pilot study demonstrates a high prevalence of exercise-induced ST-segment depression in asymptomatic, middle-aged, overweight women. Peripheral vascular endothelial dysfunction did not predict Ex-ECG ST-segment depression. Further work is needed to investigate the utility of vascular endothelial testing and Ex-ECG for IHD diagnostic and management purposes in women. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  16. Electrocardiogram changes and atrial arrhythmias in individuals carrying sodium channel SCN5A D1275N mutation.

    PubMed

    Vanninen, Sari U M; Nikus, Kjell; Aalto-Setälä, Katriina

    2017-09-01

    The cardiac sodium channel SCN5A regulates atrioventricular and ventricular depolarization as well as cardiac conduction. Patients with cardiac electrical abnormalities have an increased risk of sudden cardiac death (SCD) and cardio-embolic stroke. Optimal management of cardiac disease includes the understanding of association between the causative mutations and the clinical phenotype. A 12-lead electrocardiogram (ECG) is an easy and inexpensive tool for finding risk patients. A blood sample for DNA extraction was obtained in a Finnish family with 43 members; systematic 12-lead ECG analysis was performed in 13 of the family members carrying an SCN5A D1275N mutation. Conduction defects and supraventricular arrhythmias, including atrial fibrillation/flutter, atrioventricular nodal re-entry tachycardia (AVNRT) and junctional rhythm were searched for. Five (38%) mutation carriers had fascicular or bundle branch block, 10 had atrial arrhythmias; no ventricular arrhythmias were found. Notching of the R- and S waves - including initial QRS fragmentation - and prolonged S-wave upstroke were present in all the affected family members. Notably, four (31%) affected family members had a stroke before the age of 31 and two experienced premature death. A 12-lead ECG can be used to predict arrhythmias in SCN5A D1275N mutation carriers. Key messages The 12-lead ECG may reveal cardiac abnormalities even before clinical symptoms occur. Specific ECG findings - initial QRS fragmentation, prolonged S-wave upstroke as well as supraventricular arrhythmias - were frequently encountered in all SCN5A D1257N mutation carriers. ECG follow-up is recommended for all SCN5A D1275N mutation carriers.

  17. Custom FPGA processing for real-time fetal ECG extraction and identification.

    PubMed

    Torti, E; Koliopoulos, D; Matraxia, M; Danese, G; Leporati, F

    2017-01-01

    Monitoring the fetal cardiac activity during pregnancy is of crucial importance for evaluating fetus health. However, there is a lack of automatic and reliable methods for Fetal ECG (FECG) monitoring that can perform this elaboration in real-time. In this paper, we present a hardware architecture, implemented on the Altera Stratix V FPGA, capable of separating the FECG from the maternal ECG and to correctly identify it. We evaluated our system using both synthetic and real tracks acquired from patients beyond the 20th pregnancy week. This work is part of a project aiming at developing a portable system for FECG continuous real-time monitoring. Its characteristics of reduced power consumption, real-time processing capability and reduced size make it suitable to be embedded in the overall system, that is the first proposed exploiting Blind Source Separation with this technology, to the best of our knowledge. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Reconfigurable Embedded System for Electrocardiogram Acquisition.

    PubMed

    Kay, Marcel Seiji; Iaione, Fábio

    2015-01-01

    Smartphones include features that offers the chance to develop mobile systems in medical field, resulting in an area called mobile-health. One of the most common medical examinations is the electrocardiogram (ECG), which allows the diagnosis of various heart diseases, leading to preventative measures and preventing more serious problems. The objective of this study was to develop a wireless reconfigurable embedded system using a FPAA (Field Programmable Analog Array), for the acquisition of ECG signals, and an application showing and storing these signals on Android smartphones. The application also performs the partial FPAA reconfiguration in real time (adjustable gain). Previous studies using FPAA usually use the development boards provided by the manufacturer (high cost), do not allow the reconfiguration in real time, use no smartphone and communicate via cables. The parameters tested in the acquisition circuit and the quality of ECGs registered in an individual were satisfactory.

  19. Development and study of aluminum-air electrochemical generator and its main components

    NASA Astrophysics Data System (ADS)

    Ilyukhina, A. V.; Kleymenov, B. V.; Zhuk, A. Z.

    2017-02-01

    Aluminum-air power sources are receiving increased attention for applications in portable electronic devices, transportation, and energy systems. This study reports on the development of an aluminum-air electrochemical generator (AA ECG) and provides a technical foundation for the selection of its components, i.e., aluminum anode, gas diffusion cathode, and alkaline electrolyte. A prototype 1.5 kW AA ECG with specific energy of 270 Wh kg-1 is built and tested. The results of this study demonstrate the feasibility of AA ECGs as portable reserve and emergency power sources, as well as power sources for electric vehicles.

  20. Multichannel techniques for motion artifacts removal from electrocardiographic signals.

    PubMed

    Milanesi, M; Martini, N; Vanello, N; Positano, V; Santarelli, M F; Paradiso, R; De Rossi, D; Landini, L

    2006-01-01

    Electrocardiographic (ECG) signals are affected by several kinds of artifacts, that may hide vital signs of interest. Motion artifacts, due to the motion of the electrodes in relation to patient skin, are particularly frequent in bioelectrical signals acquired by wearable systems. In this paper we propose different approaches in order to get rid of motion confounds. The first approach we follow starts from measuring electrode motion provided by an accelerometer placed on the electrode and use this measurement in an adaptive filtering system to remove the noise present in the ECG. The second approach is based on independent component analysis methods applied to multichannel ECG recordings; we propose to use both instantaneous model and a frequency domain implementation of the convolutive model that accounts for different paths of the source signals to the electrodes.

  1. Orbit-orbit relativistic correction calculated with all-electron molecular explicitly correlated Gaussians.

    PubMed

    Stanke, Monika; Palikot, Ewa; Kȩdziera, Dariusz; Adamowicz, Ludwik

    2016-12-14

    An algorithm for calculating the first-order electronic orbit-orbit magnetic interaction correction for an electronic wave function expanded in terms of all-electron explicitly correlated molecular Gaussian (ECG) functions with shifted centers is derived and implemented. The algorithm is tested in calculations concerning the H 2 molecule. It is also applied in calculations for LiH and H 3 + molecular systems. The implementation completes our work on the leading relativistic correction for ECGs and paves the way for very accurate ECG calculations of ground and excited potential energy surfaces (PESs) of small molecules with two and more nuclei and two and more electrons, such as HeH - , H 3 + , HeH 2 + , and LiH 2 + . The PESs will be used to determine rovibrational spectra of the systems.

  2. A Modular Low-Complexity ECG Delineation Algorithm for Real-Time Embedded Systems.

    PubMed

    Bote, Jose Manuel; Recas, Joaquin; Rincon, Francisco; Atienza, David; Hermida, Roman

    2018-03-01

    This work presents a new modular and low-complexity algorithm for the delineation of the different ECG waves (QRS, P and T peaks, onsets, and end). Involving a reduced number of operations per second and having a small memory footprint, this algorithm is intended to perform real-time delineation on resource-constrained embedded systems. The modular design allows the algorithm to automatically adjust the delineation quality in runtime to a wide range of modes and sampling rates, from a ultralow-power mode when no arrhythmia is detected, in which the ECG is sampled at low frequency, to a complete high-accuracy delineation mode, in which the ECG is sampled at high frequency and all the ECG fiducial points are detected, in the case of arrhythmia. The delineation algorithm has been adjusted using the QT database, providing very high sensitivity and positive predictivity, and validated with the MIT database. The errors in the delineation of all the fiducial points are below the tolerances given by the Common Standards for Electrocardiography Committee in the high-accuracy mode, except for the P wave onset, for which the algorithm is above the agreed tolerances by only a fraction of the sample duration. The computational load for the ultralow-power 8-MHz TI MSP430 series microcontroller ranges from 0.2% to 8.5% according to the mode used.

  3. Optimisation of Embryonic and Larval ECG Measurement in Zebrafish for Quantifying the Effect of QT Prolonging Drugs

    PubMed Central

    Dhillon, Sundeep Singh; Dóró, Éva; Magyary, István; Egginton, Stuart; Sík, Attila; Müller, Ferenc

    2013-01-01

    Effective chemical compound toxicity screening is of paramount importance for safe cardiac drug development. Using mammals in preliminary screening for detection of cardiac dysfunction by electrocardiography (ECG) is costly and requires a large number of animals. Alternatively, zebrafish embryos can be used as the ECG waveform is similar to mammals, a minimal amount of chemical is necessary for drug testing, while embryos are abundant, inexpensive and represent replacement in animal research with reduced bioethical concerns. We demonstrate here the utility of pre-feeding stage zebrafish larvae in detection of cardiac dysfunction by electrocardiography. We have optimised an ECG recording system by addressing key parameters such as the form of immobilization, recording temperature, electrode positioning and developmental age. Furthermore, analysis of 3 days post fertilization (dpf) zebrafish embryos treated with known QT prolonging drugs such as terfenadine, verapamil and haloperidol led to reproducible detection of QT prolongation as previously shown for adult zebrafish. In addition, calculation of Z-factor scores revealed that the assay was sensitive and specific enough to detect large drug-induced changes in QTc intervals. Thus, the ECG recording system is a useful drug-screening tool to detect alteration to cardiac cycle components and secondary effects such as heart block and arrhythmias in zebrafish larvae before free feeding stage, and thus provides a suitable replacement for mammalian experimentation. PMID:23579446

  4. Prediction of County-Level Corn Yields Using an Energy-Crop Growth Index.

    NASA Astrophysics Data System (ADS)

    Andresen, Jeffrey A.; Dale, Robert F.; Fletcher, Jerald J.; Preckel, Paul V.

    1989-01-01

    Weather conditions significantly affect corn yields. while weather remains as the major uncontrolled variable in crop production, an understanding of the influence of weather on yields can aid in early and accurate assessment of the impact of weather and climate on crop yields and allow for timely agricultural extension advisories to help reduce farm management costs and improve marketing, decisions. Based on data for four representative countries in Indiana from 1960 to 1984 (excluding 1970 because of the disastrous southern corn leaf blight), a model was developed to estimate corn (Zea mays L.) yields as a function of several composite soil-crop-weather variables and a technology-trend marker, applied nitrogen fertilizer (N). The model was tested by predicting corn yields for 15 other counties. A daily energy-crop growth (ECG) variable in which different weights were used for the three crop-weather variables which make up the daily ECG-solar radiation intercepted by the canopy, a temperature function, and the ratio of actual to potential evapotranspiration-performed better than when the ECG components were weighted equally. The summation of the weighted daily ECG over a relatively short period (36 days spanning silk) was found to provide the best index for predicting county average corn yield. Numerical estimation results indicate that the ratio of actual to potential evapotranspiration (ET/PET) is much more important than the other two ECG factors in estimating county average corn yield in Indiana.

  5. Cardiovascular emergencies in primary care: an observational retrospective study of a large-scale telecardiology service.

    PubMed

    Marcolino, Milena Soriano; Santos, Thales Matheus Mendonça; Stefanelli, Fernanda Cotrim; Oliveira, João Antonio de Queiroz; E Silva, Maíra Viana Rego Souza; Andrade, Diomildo Ferreira; Silva, Grace Kelly Matos E; Ribeiro, Antonio Luiz

    2017-01-01

    Electrocardiograms (ECGs) are an essential examination for identification and management of cardiovascular emergencies.The aim of this study was to report on the frequency and recognition of cardiovascular emergencies in primary care units. Observational retrospective study assessing consecutive patients whose digital ECGs were sent for analysis to the team of the Telehealth Network of Minas Gerais. Data from patients diagnosed with cardiological emergencies in the primary care setting of 750 municipalities in Minas Gerais, Brazil, between March and September 2015, were collected via telephone contact with the healthcare practitioner who performed the ECG. After collection, the data were subjected to statistical analysis. Over the study period, 304 patients with cardiovascular emergencies were diagnosed within primary care. Only 73.4% of these were recognized by the local physicians. Overall, the most frequent ECG abnormalities were acute ischemic patterns (44.7%) and the frequency of such patterns was higher among the ECGs assigned as emergency priority (P = 0.03). It was possible to obtain complete information on 231 patients (75.9%). Among these, the mean age was 65 ± 14.4 years, 57.1% were men and the most prevalent comorbidity was hypertension (68.4%). In total, 77.9% were referred to a unit caring for cases of higher complexity and 11.7% of the patients died. In this study, cardiovascular emergencies were misdiagnosed in primary care settings, acute myocardial ischemia was the most frequent emergency and the mortality rate was high.

  6. Seismocardiography-Based Cardiac Computed Tomography Gating Using Patient-Specific Template Identification and Detection

    PubMed Central

    Yao, Jingting; Tridandapani, Srini; Wick, Carson A.

    2017-01-01

    To more accurately trigger cardiac computed tomography angiography (CTA) than electrocardiography (ECG) alone, a sub-system is proposed as an intermediate step toward fusing ECG with seismocardiography (SCG). Accurate prediction of quiescent phases is crucial to prospectively gating CTA, which is susceptible to cardiac motion and, thus, can affect the diagnostic quality of images. The key innovation of this sub-system is that it identifies the SCG waveform corresponding to heart sounds and determines their phases within the cardiac cycles. Furthermore, this relationship is modeled as a linear function with respect to heart rate. For this paper, B-mode echocardiography is used as the gold standard for identifying the quiescent phases. We analyzed synchronous ECG, SCG, and echocardiography data acquired from seven healthy subjects (mean age: 31; age range: 22–48; males: 4) and 11 cardiac patients (mean age: 56; age range: 31–78; males: 6). On average, the proposed algorithm was able to successfully identify 79% of the SCG waveforms in systole and 68% in diastole. The simulated results show that SCG-based prediction produced less average phase error than that of ECG. It was found that the accuracy of ECG-based gating is more susceptible to increases in heart rate variability, while SCG-based gating is susceptible to high cycle to cycle variability in morphology. This pilot work of prediction using SCG waveforms enriches the framework of a comprehensive system with multiple modalities that could potentially, in real time, improve the image quality of CTA. PMID:28845370

  7. Combined Electrocardiography- and Respiratory-Triggered CT of the Lung to Reduce Respiratory Misregistration Artifacts between Imaging Slabs in Free-Breathing Children: Initial Experience

    PubMed Central

    Allmendinger, Thomas

    2017-01-01

    Objective Cardiac and respiratory motion artifacts degrade the image quality of lung CT in free-breathing children. The aim of this study was to evaluate the effect of combined electrocardiography (ECG) and respiratory triggering on respiratory misregistration artifacts on lung CT in free-breathing children. Materials and Methods In total, 15 children (median age 19 months, range 6 months–8 years; 7 boys), who underwent free-breathing ECG-triggered lung CT with and without respiratory-triggering were included. A pressure-sensing belt of a respiratory gating system was used to obtain the respiratory signal. The degree of respiratory misregistration artifacts between imaging slabs was graded on a 4-point scale (1, excellent image quality) on coronal and sagittal images and compared between ECG-triggered lung CT studies with and without respiratory triggering. A p value < 0.05 was considered significant. Results Lung CT with combined ECG and respiratory triggering showed significantly less respiratory misregistration artifacts than lung CT with ECG triggering only (1.1 ± 0.4 vs. 2.2 ± 1.0, p = 0.003). Conclusion Additional respiratory-triggering reduces respiratory misregistration artifacts on ECG-triggered lung CT in free-breathing children. PMID:28860904

  8. IT-based diagnostic instrumentation systems for personalized healthcare services.

    PubMed

    Chun, Honggu; Kang, Jaemin; Kim, Ki-Jung; Park, Kwang Suk; Kim, Hee Chan

    2005-01-01

    This paper describes recent research and development activities on the diagnostic instruments for personalized healthcare services in Seoul National University. Utilizing the state-of-the-art information technologies (IT), various diagnostic medical instruments have been integrated into a personal wearable device and a home telehealthcare system. We developed a wrist-worn integrated health monitoring device (WIHMD) which performs the measurements of non-invasive blood pressure (NIBP), pulse oximetry (SpO2), electrocardiogram (ECG), respiration rate, heart rate, and body surface temperature and the detection of falls to determine the onset of emergency situation. The WIHMD also analyzes the acquired bio-signals and transmits the resultant data to a healthcare service center through a commercial cellular phone. Two different kinds of IT-based blood glucometer have been developed using a cellular phone and PDA(personal digital assistant) as a main unit. A blood glucometer was also integrated within a wrist pressure measurement module which is interfaced with a cellular phone via Telecommunications Technology Association (TTA) standard in order to provide users with easiness in measuring and handling two important health parameters. Non-intrusive bio-signal measurement systems were developed for the ease of home use. One can measure his ECG on a bed while he is sleeping; measure his ECG, body temperature, bodyfat ratio and weight on a toilet seat; measure his ECG on a chair; and estimate the degree of activity by motion analysis using a camera. Another integrated diagnostic system for home telehealthcare services has been developed to include a 12 channels ECG, a pressure meter for NIBP, a blood glucometer, a bodyfat meter and a spirometer. It is an expert system to analyze the measured health data and based on the diagnostic result, the system provides an appropriate medical consultation. The measured data can be either stored on the system or transmitted to the central server through the internet. We have installed the developed systems on a model house for the performance evaluation and confirmed the possibility of the system as an effective tool for the personalized healthcare services.

  9. Arrhythmia recognition and classification using combined linear and nonlinear features of ECG signals.

    PubMed

    Elhaj, Fatin A; Salim, Naomie; Harris, Arief R; Swee, Tan Tian; Ahmed, Taqwa

    2016-04-01

    Arrhythmia is a cardiac condition caused by abnormal electrical activity of the heart, and an electrocardiogram (ECG) is the non-invasive method used to detect arrhythmias or heart abnormalities. Due to the presence of noise, the non-stationary nature of the ECG signal (i.e. the changing morphology of the ECG signal with respect to time) and the irregularity of the heartbeat, physicians face difficulties in the diagnosis of arrhythmias. The computer-aided analysis of ECG results assists physicians to detect cardiovascular diseases. The development of many existing arrhythmia systems has depended on the findings from linear experiments on ECG data which achieve high performance on noise-free data. However, nonlinear experiments characterize the ECG signal more effectively sense, extract hidden information in the ECG signal, and achieve good performance under noisy conditions. This paper investigates the representation ability of linear and nonlinear features and proposes a combination of such features in order to improve the classification of ECG data. In this study, five types of beat classes of arrhythmia as recommended by the Association for Advancement of Medical Instrumentation are analyzed: non-ectopic beats (N), supra-ventricular ectopic beats (S), ventricular ectopic beats (V), fusion beats (F) and unclassifiable and paced beats (U). The characterization ability of nonlinear features such as high order statistics and cumulants and nonlinear feature reduction methods such as independent component analysis are combined with linear features, namely, the principal component analysis of discrete wavelet transform coefficients. The features are tested for their ability to differentiate different classes of data using different classifiers, namely, the support vector machine and neural network methods with tenfold cross-validation. Our proposed method is able to classify the N, S, V, F and U arrhythmia classes with high accuracy (98.91%) using a combined support vector machine and radial basis function method. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Using computerised interactive response technology to assess electrocardiographers and for aggregating diagnoses.

    PubMed

    Peace, Aaron; Ramsewak, Adesh; Cairns, Andrew; Finlay, Dewar; Guldenring, Daniel; Clifford, Gari; Bond, Raymond

    2015-01-01

    The 12-lead electrocardiogram (ECG) is a crucial diagnostic tool. However, the ideal method to assess competency in ECG interpretation remains unclear. We sought to evaluate whether keypad response technology provides a rapid, interactive way to assess ECG knowledge. 75 participants were enrolled [32 (43%) Primary Care Physicians, 24 (32%) Hospital Medical Staff and 19 (25%) Nurse Practitioners]. Nineteen ECGs with 4 possible answers were interpreted. Out of 1425 possible decisions 1054 (73.9%) responses were made. Only 570/1425 (40%) of the responses were correct. Diagnostic accuracy varied (0% to 78%, mean 42%±21%) across the entire cohort. Participation was high, (median 83%, IQR 50%-100%). Hospital Medical Staff had significantly higher diagnostic accuracy than nurse practitioners (50±20% vs. 38±19%, p=0.04) and Primary Care Physicians (50±20% vs. 40±21%, p=0.07) although not significant. Interactive voting systems can be rapidly and successfully used to assess ECG interpretation. Further education is necessary to improve diagnostic accuracy. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  11. Robust QRS detection for HRV estimation from compressively sensed ECG measurements for remote health-monitoring systems.

    PubMed

    Pant, Jeevan K; Krishnan, Sridhar

    2018-03-15

    To present a new compressive sensing (CS)-based method for the acquisition of ECG signals and for robust estimation of heart-rate variability (HRV) parameters from compressively sensed measurements with high compression ratio. CS is used in the biosensor to compress the ECG signal. Estimation of the locations of QRS segments is carried out by applying two algorithms on the compressed measurements. The first algorithm reconstructs the ECG signal by enforcing a block-sparse structure on the first-order difference of the signal, so the transient QRS segments are significantly emphasized on the first-order difference of the signal. Multiple block-divisions of the signals are carried out with various block lengths, and multiple reconstructed signals are combined to enhance the robustness of the localization of the QRS segments. The second algorithm removes errors in the locations of QRS segments by applying low-pass filtering and morphological operations. The proposed CS-based method is found to be effective for the reconstruction of ECG signals by enforcing transient QRS structures on the first-order difference of the signal. It is demonstrated to be robust not only to high compression ratio but also to various artefacts present in ECG signals acquired by using on-body wireless sensors. HRV parameters computed by using the QRS locations estimated from the signals reconstructed with a compression ratio as high as 90% are comparable with that computed by using QRS locations estimated by using the Pan-Tompkins algorithm. The proposed method is useful for the realization of long-term HRV monitoring systems by using CS-based low-power wireless on-body biosensors.

  12. Design of Secure ECG-Based Biometric Authentication in Body Area Sensor Networks

    PubMed Central

    Peter, Steffen; Pratap Reddy, Bhanu; Momtaz, Farshad; Givargis, Tony

    2016-01-01

    Body area sensor networks (BANs) utilize wireless communicating sensor nodes attached to a human body for convenience, safety, and health applications. Physiological characteristics of the body, such as the heart rate or Electrocardiogram (ECG) signals, are promising means to simplify the setup process and to improve security of BANs. This paper describes the design and implementation steps required to realize an ECG-based authentication protocol to identify sensor nodes attached to the same human body. Therefore, the first part of the paper addresses the design of a body-area sensor system, including the hardware setup, analogue and digital signal processing, and required ECG feature detection techniques. A model-based design flow is applied, and strengths and limitations of each design step are discussed. Real-world measured data originating from the implemented sensor system are then used to set up and parametrize a novel physiological authentication protocol for BANs. The authentication protocol utilizes statistical properties of expected and detected deviations to limit the number of false positive and false negative authentication attempts. The result of the described holistic design effort is the first practical implementation of biometric authentication in BANs that reflects timing and data uncertainties in the physical and cyber parts of the system. PMID:27110785

  13. Telecardiology for effective healthcare services.

    PubMed

    Saxena, S C; Kumar, V; Giri, V K

    2003-01-01

    Continuous monitoring of the electrocardiogram (ECG) and other signals related to current heart activity are necessary for patients who are suffering from cardiac diseases. This paper deals with the work that has been carried out to transmit ECGs from remote sites. Software has been developed which enables the uploading of ECG data from a patient so that the physician can monitor the state of the patient from a distance and at the same time may consult other experts for a second opinion. Records can only be examined by the authorized physician after proper registration and diagnosis or prescription may be sent back to the referring site. Further consultation with the patient through a 'chat' facility is also possible. The suitability of the system over transport control protocol (TCP), internet protocol (IP), local area network (LAN), wide area network (WAN) and World Wide Web (WWW) has been assessed. The bandwidth, latency, availability, security and ubiquity have also been discussed. A study has also been undertaken in order to make the system compatible with available bandwidths and to find out which one out of a number of available techniques is most efficient for ECG data compression. The results indicate that the scheme is suitable for telecardiology and can form part of an overall telemedicine system in a health care network.

  14. Design of Secure ECG-Based Biometric Authentication in Body Area Sensor Networks.

    PubMed

    Peter, Steffen; Reddy, Bhanu Pratap; Momtaz, Farshad; Givargis, Tony

    2016-04-22

    Body area sensor networks (BANs) utilize wireless communicating sensor nodes attached to a human body for convenience, safety, and health applications. Physiological characteristics of the body, such as the heart rate or Electrocardiogram (ECG) signals, are promising means to simplify the setup process and to improve security of BANs. This paper describes the design and implementation steps required to realize an ECG-based authentication protocol to identify sensor nodes attached to the same human body. Therefore, the first part of the paper addresses the design of a body-area sensor system, including the hardware setup, analogue and digital signal processing, and required ECG feature detection techniques. A model-based design flow is applied, and strengths and limitations of each design step are discussed. Real-world measured data originating from the implemented sensor system are then used to set up and parametrize a novel physiological authentication protocol for BANs. The authentication protocol utilizes statistical properties of expected and detected deviations to limit the number of false positive and false negative authentication attempts. The result of the described holistic design effort is the first practical implementation of biometric authentication in BANs that reflects timing and data uncertainties in the physical and cyber parts of the system.

  15. ECG-derived respiration based on iterated Hilbert transform and Hilbert vibration decomposition.

    PubMed

    Sharma, Hemant; Sharma, K K

    2018-06-01

    Monitoring of the respiration using the electrocardiogram (ECG) is desirable for the simultaneous study of cardiac activities and the respiration in the aspects of comfort, mobility, and cost of the healthcare system. This paper proposes a new approach for deriving the respiration from single-lead ECG based on the iterated Hilbert transform (IHT) and the Hilbert vibration decomposition (HVD). The ECG signal is first decomposed into the multicomponent sinusoidal signals using the IHT technique. Afterward, the lower order amplitude components obtained from the IHT are filtered using the HVD to extract the respiration information. Experiments are performed on the Fantasia and Apnea-ECG datasets. The performance of the proposed ECG-derived respiration (EDR) approach is compared with the existing techniques including the principal component analysis (PCA), R-peak amplitudes (RPA), respiratory sinus arrhythmia (RSA), slopes of the QRS complex, and R-wave angle. The proposed technique showed the higher median values of correlation (first and third quartile) for both the Fantasia and Apnea-ECG datasets as 0.699 (0.55, 0.82) and 0.57 (0.40, 0.73), respectively. Also, the proposed algorithm provided the lowest values of the mean absolute error and the average percentage error computed from the EDR and reference (recorded) respiration signals for both the Fantasia and Apnea-ECG datasets as 1.27 and 9.3%, and 1.35 and 10.2%, respectively. In the experiments performed over different age group subjects of the Fantasia dataset, the proposed algorithm provided effective results in the younger population but outperformed the existing techniques in the case of elderly subjects. The proposed EDR technique has the advantages over existing techniques in terms of the better agreement in the respiratory rates and specifically, it reduces the need for an extra step required for the detection of fiducial points in the ECG for the estimation of respiration which makes the process effective and less-complex. The above performance results obtained from two different datasets validate that the proposed approach can be used for monitoring of the respiration using single-lead ECG.

  16. A Hybrid Approach to Detect Driver Drowsiness Utilizing Physiological Signals to Improve System Performance and Wearability.

    PubMed

    Awais, Muhammad; Badruddin, Nasreen; Drieberg, Micheal

    2017-08-31

    Driver drowsiness is a major cause of fatal accidents, injury, and property damage, and has become an area of substantial research attention in recent years. The present study proposes a method to detect drowsiness in drivers which integrates features of electrocardiography (ECG) and electroencephalography (EEG) to improve detection performance. The study measures differences between the alert and drowsy states from physiological data collected from 22 healthy subjects in a driving simulator-based study. A monotonous driving environment is used to induce drowsiness in the participants. Various time and frequency domain feature were extracted from EEG including time domain statistical descriptors, complexity measures and power spectral measures. Features extracted from the ECG signal included heart rate (HR) and heart rate variability (HRV), including low frequency (LF), high frequency (HF) and LF/HF ratio. Furthermore, subjective sleepiness scale is also assessed to study its relationship with drowsiness. We used paired t -tests to select only statistically significant features ( p < 0.05), that can differentiate between the alert and drowsy states effectively. Significant features of both modalities (EEG and ECG) are then combined to investigate the improvement in performance using support vector machine (SVM) classifier. The other main contribution of this paper is the study on channel reduction and its impact to the performance of detection. The proposed method demonstrated that combining EEG and ECG has improved the system's performance in discriminating between alert and drowsy states, instead of using them alone. Our channel reduction analysis revealed that an acceptable level of accuracy (80%) could be achieved by combining just two electrodes (one EEG and one ECG), indicating the feasibility of a system with improved wearability compared with existing systems involving many electrodes. Overall, our results demonstrate that the proposed method can be a viable solution for a practical driver drowsiness system that is both accurate and comfortable to wear.

  17. ECG Holter monitor with alert system and mobile application

    NASA Astrophysics Data System (ADS)

    Teron, Abigail C.; Rivera, Pedro A.; Goenaga, Miguel A.

    2016-05-01

    This paper proposes a new approach on the Holter monitor by creating a portable Electrocardiogram (ECG) Holter monitor that will alert the user by detecting abnormal heart beats using a digital signal processing software. The alarm will be triggered when the patient experiences arrhythmias such as bradycardia and tachycardia. The equipment is simple, comfortable and small in size that fit in the hand. It can be used at any time and any moment by placing three leads to the person's chest which is connected to an electronic circuit. The ECG data will be transmitted via Bluetooth to the memory of a selected mobile phone using an application that will store the collected data for up to 24 hrs. The arrhythmia is identified by comparing the reference signals with the user's signal. The diagnostic results demonstrate that the ECG Holter monitor alerts the user when an arrhythmia is detected thru the Holter monitor and mobile application.

  18. Secure chaotic transmission of electrocardiography signals with acousto-optic modulation under profiled beam propagation.

    PubMed

    Almehmadi, Fares S; Chatterjee, Monish R

    2015-01-10

    Electrocardiography (ECG) signals are used for both medical purposes and identifying individuals. It is often necessary to encrypt this highly sensitive information before it is transmitted over any channel. A closed-loop acousto-optic hybrid device acting as a chaotic modulator is applied to ECG signals to achieve this encryption. Recently improved modeling of this approach using profiled optical beams has shown it to be very sensitive to key parameters that characterize the encryption and decryption process, exhibiting its potential for secure transmission of analog and digital signals. Here the encryption and decryption is demonstrated for ECG signals, both analog and digital versions, illustrating strong encryption without significant distortion. Performance analysis pertinent to both analog and digital transmission of the ECG waveform is also carried out using output signal-to-noise, signal-to-distortion, and bit-error-rate measures relative to the key parameters and presence of channel noise in the system.

  19. Classification of cardiac patient states using artificial neural networks

    PubMed Central

    Kannathal, N; Acharya, U Rajendra; Lim, Choo Min; Sadasivan, PK; Krishnan, SM

    2003-01-01

    Electrocardiogram (ECG) is a nonstationary signal; therefore, the disease indicators may occur at random in the time scale. This may require the patient be kept under observation for long intervals in the intensive care unit of hospitals for accurate diagnosis. The present study examined the classification of the states of patients with certain diseases in the intensive care unit using their ECG and an Artificial Neural Networks (ANN) classification system. The states were classified into normal, abnormal and life threatening. Seven significant features extracted from the ECG were fed as input parameters to the ANN for classification. Three neural network techniques, namely, back propagation, self-organizing maps and radial basis functions, were used for classification of the patient states. The ANN classifier in this case was observed to be correct in approximately 99% of the test cases. This result was further improved by taking 13 features of the ECG as input for the ANN classifier. PMID:19649222

  20. ECG denoising with adaptive bionic wavelet transform.

    PubMed

    Sayadi, Omid; Shamsollahi, Mohammad Bagher

    2006-01-01

    In this paper a new ECG denoising scheme is proposed using a novel adaptive wavelet transform, named bionic wavelet transform (BWT), which had been first developed based on a model of the active auditory system. There has been some outstanding features with the BWT such as nonlinearity, high sensitivity and frequency selectivity, concentrated energy distribution and its ability to reconstruct signal via inverse transform but the most distinguishing characteristic of BWT is that its resolution in the time-frequency domain can be adaptively adjusted not only by the signal frequency but also by the signal instantaneous amplitude and its first-order differential. Besides by optimizing the BWT parameters parallel to modifying a new threshold value, one can handle ECG denoising with results comparing to those of wavelet transform (WT). Preliminary tests of BWT application to ECG denoising were constructed on the signals of MIT-BIH database which showed high performance of noise reduction.

  1. A portable ECG monitoring device with Bluetooth and Holter capabilities for telemedicine applications.

    PubMed

    Lucani, Daniel; Cataldo, Giancarlos; Cruz, Julio; Villegas, Guillermo; Wong, Sara

    2006-01-01

    A prototype of a portable ECG-monitoring device has been developed for clinical and non-clinical environments as part of a telemedicine system to provide remote and continuous surveillance of patients. The device can acquire, store and/or transmit ECG signals to computer-based platforms or specially configured access points (AP) with Intranet/Internet capabilities in order to reach remote monitoring stations. Acquired data can be stored in a flash memory card in FAT16 format for later recovery, or transmitted via Bluetooth or USB to a local station or AP. This data acquisition module (DAM) operates in two modes: Holter and on-line transmission.

  2. Response of the ECG to short-term diuresis in patients with heart failure.

    PubMed

    Madias, John E; Song, Jessica; White, C Michael; Kalus, James S; Kluger, Jeffrey

    2005-07-01

    Increase in the amplitude of electrocardiogram (ECG) QRS complexes has been observed in patients treated for heart failure (HF), but the underlying mechanism has not been delineated. Also, correlation of augmentation of the QRS potentials with loss of weight has been noted in patients recovering from anasarca of varying etiology, or after hemodialysis. We assessed the effect of diuresis-based fluid loss in patients treated for HF on the amplitude of ECG QRS complexes. This is a cohort study based on ECG and other data from a previously published investigation of patients with HF conducted at a university affiliated hospital, which used new measurements and analysis, performed by a totally blinded investigator based at another institution. Twenty-one patients (10 men) aged 70.5+/-12.7 years, 13 with ischemic, and 8 with nonischemic cardiomyopathy, were admitted to the hospital for management of exacerbated HF and were observed for 48 hours. The patients received diuresis, and had routine laboratory testing, documentation of the net fluid lost, and recording of ECGs prior to the initiation of therapy and at 24 and 48 hours. Percent change (%Delta) over the course of observation in the sums of the amplitude of QRS complexes from 12 leads (SigmaQRS12), 6-limb leads (SigmaQRS6), and leads 1+2 (SigmaQRS2) in mm of standard ECGs were correlated with net fluid loss corrected for admission weight in mL/kg. Fluid loss amounted to 3204.9+/-1399.5 mL in the course of 40+/-23 hours of diuresis. SigmaQRS12 was 160.9+/-42.3 mm before and 170.0+/-50.7 mm after diuresis (P=0. 024). Percent change in SigmaQRS12, SigmaQRS6, and SigmaQRS2 correlated well with the net fluid loss (r=-0.70, -0.82, -0.61, and P=0.002, 0.0005, 0.001) correspondingly. Changes in sums of the amplitude of QRS complexes of the standard ECG correlates well with net fluid loss in response to short-term diuresis in patients with HF. Change in the SigmaQRS12, SigmaQRS6, and SigmaQRS2 from ECGs before and after diuresis can be used as an easily obtainable and universally available bedside index of the net fluid loss experienced by bedridden patients with HF undergoing therapy.

  3. Panoramic ECG display versus conventional ECG: ischaemia detection by critical care nurses.

    PubMed

    Wilson, Nick; Hassani, Aimen; Gibson, Vanessa; Lightfoot, Timothy; Zizzo, Claudio

    2012-01-01

    To compare accuracy and certainty of diagnosis of cardiac ischaemia using the Panoramic ECG display tool plus conventional 12-lead electrocardiogram (ECG) versus 12-lead ECG alone by UK critical care nurses who were members of the British Association of Critical Care Nurses (BACCN). Critically ill patients are prone to myocardial ischaemia. Symptoms may be masked by sedation or analgesia, and ECG changes may be the only sign. Critical care nurses have an essential role in detecting ECG changes promptly. Despite this, critical care nurses may lack expertise in interpreting ECGs and myocardial ischaemia often goes undetected by critical care staff. British Association of Critical Care Nurses (BACCN) members were invited to complete an online survey to evaluate the analysis of two sets of eight ECGs displayed alone and with the new display device. Data from 82 participants showed diagnostic accuracy improved from 67·1% reading ECG traces alone, to 96·0% reading ECG plus Panoramic ECG display tool (P < 0·01, significance level α = 0·05). Participants' diagnostic certainty score rose from 41·7% reading ECG alone to 66·8% reading ECG plus Panoramic ECG display tool (P < 0·01, α = 0·05). The Panoramic ECG display tool improves both accuracy and certainty of detecting ST segment changes among critical care nurses, when compared to conventional 12-lead ECG alone. This benefit was greatest with early ischaemic changes. Critical care nurses who are least confident in reading conventional ECGs benefit the most from the new display. Critical care nurses have an essential role in the monitoring of critically ill patients. However, nurses do not always have the expertise to detect subtle ischaemic ECG changes promptly. Introduction of the Panoramic ECG display tool into clinical practice could lead to patients receiving treatment for myocardial ischaemia sooner with the potential for reduction in morbidity and mortality. © 2012 The Authors. Nursing in Critical Care © 2012 British Association of Critical Care Nurses.

  4. Home-based mobile cardio-pulmonary rehabilitation consultant system.

    PubMed

    Lee, Hsu-En; Wang, Wen-Chih; Lu, Shao-Wei; Wu, Bo-Yuan; Ko, Li-Wei

    2011-01-01

    Cardiovascular diseases are the most popular cause of death in the world recently. For postoperatives, cardiac rehabilitation is still asked to maintain at home (phase II) to improve cardiac function. However, only one third of outpatients do the exercise regularly, reflecting the difficulty for home-based healthcare: lacking of monitoring and motivation. Hence, a cardio-pulmonary rehabilitation system was proposed in this research to improve rehabilitation efficiency for better prognosis. The proposed system was built on mobile phone and receiving electrocardiograph (ECG) signal from a wireless ECG holter via Bluetooth connection. Apart from heart rate (HR) monitor, an ECG derived respiration (EDR) technique is also included to provide respiration rate (RR). Both HR and RR are the most important vital signs during exercise but only used one physiological signal recorder in this system. In clinical test, there were 15 subjects affording Bruce Task (treadmill) to simulate rehabilitation procedure. Correlation between this system and commercial product (Custo-Med) was up to 98% in HR and 81% in RR. Considering the prevention of sudden heart attack, an arrhythmia detection expert system and healthcare server at the backend were also integrated to this system for comprehensive cardio-pulmonary monitoring whenever and wherever doing the exercise.

  5. Assessing ECG signal quality indices to discriminate ECGs with artefacts from pathologically different arrhythmic ECGs.

    PubMed

    Daluwatte, C; Johannesen, L; Galeotti, L; Vicente, J; Strauss, D G; Scully, C G

    2016-08-01

    False and non-actionable alarms in critical care can be reduced by developing algorithms which assess the trueness of an arrhythmia alarm from a bedside monitor. Computational approaches that automatically identify artefacts in ECG signals are an important branch of physiological signal processing which tries to address this issue. Signal quality indices (SQIs) derived considering differences between artefacts which occur in ECG signals and normal QRS morphology have the potential to discriminate pathologically different arrhythmic ECG segments as artefacts. Using ECG signals from the PhysioNet/Computing in Cardiology Challenge 2015 training set, we studied previously reported ECG SQIs in the scientific literature to differentiate ECG segments with artefacts from arrhythmic ECG segments. We found that the ability of SQIs to discriminate between ECG artefacts and arrhythmic ECG varies based on arrhythmia type since the pathology of each arrhythmic ECG waveform is different. Therefore, to reduce the risk of SQIs classifying arrhythmic events as noise it is important to validate and test SQIs with databases that include arrhythmias. Arrhythmia specific SQIs may also minimize the risk of misclassifying arrhythmic events as noise.

  6. History of research in Japan on electrocardiography in the racehorse

    PubMed Central

    HIRAGA, Atsushi; SUGANO, Shigeru

    2015-01-01

    ABSTRACT Since the first recording of electrocardiograms (ECGs) of a horse in Japan was carried out in 1944, studies on ECGs have been performed intensively. During the early stages of research from the 1950s to 1960s, leads to use for ECG recording were evaluated using several different approaches including unipolar leads, bipolar limb leads, and bipolar chest leads. Based on these studies, the AB lead, which is oriented along the long axis of the heart, became the standard reference method in Japan. Electrodes of the AB lead are placed on the upper 1/4th point along a straight line between the withers and the left shoulder blade (base: B), and 10 cm posterior to the left olecranon (apex: A). The incidence of equine arrhythmias among racehorses has been surveyed, and details of the electrocardiographic characteristics of several arrhythmias have been investigated. In particular, atrial fibrillation (AF) has been extensively studied, and papers have reported findings such as that paroxysmal AF occurs during racing and described electrocardiographic changes that occur at the onset of AF during exercise. Development of a radiotelemetry system for ECG recording enabled the first recording of equine ECGs during galloping in 1964, the detection of arrhythmias, and calculation of heart rate during exercise. Studies on comparative and developmental changes of ECGs have described characteristics of the equine ECGs. Future research on changes in cardiac function, including autonomic function, that occur with aging may lead to new developments in equine electrocardiography and contribute to improving the health and welfare of the horse. PMID:25829865

  7. Gradient-Induced Voltages on 12-Lead ECGs during High Duty-Cycle MRI Sequences and a Method for Their Removal considering Linear and Concomitant Gradient Terms

    PubMed Central

    Zhang, Shelley HuaLei; Ho Tse, Zion Tsz; Dumoulin, Charles L.; Kwong, Raymond Y.; Stevenson, William G.; Watkins, Ronald; Ward, Jay; Wang, Wei; Schmidt, Ehud J.

    2015-01-01

    Purpose To restore 12-lead ECG signal fidelity inside MRI by removing magnetic-field gradient induced-voltages during high gradient-duty-cycle sequences. Theory and Methods A theoretical equation was derived, providing first- and second-order electrical fields induced at individual ECG electrode as a function of gradient fields. Experiments were performed at 3T on healthy volunteers, using a customized acquisition system which captured full amplitude and frequency response of ECGs, or a commercial recording system. The 19 equation coefficients were derived by linear regression of data from accelerated sequences, and used to compute induced-voltages in real-time during full-resolution sequences to remove ECG artifacts. Restored traces were evaluated relative to ones acquired without imaging. Results Measured induced-voltages were 0.7V peak-to-peak during balanced Steady-State Free Precession (bSSFP) with heart at the isocenter. Applying the equation during gradient echo sequencing, three-dimensional fast spin echo and multi-slice bSSFP imaging restored nonsaturated traces and second-order concomitant terms showed larger contributions in electrodes farther from the magnet isocenter. Equation coefficients are evaluated with high repeatability (ρ = 0.996) and are subject, sequence, and slice-orientation dependent. Conclusion Close agreement between theoretical and measured gradient-induced voltages allowed for real-time removal. Prospective estimation of sequence-periods where large induced-voltages occur may allow hardware removal of these signals. PMID:26101951

  8. Pheochromocytoma diagnosed after anticoagulation for atrial fibrillation ablation procedure: a giant in disguise.

    PubMed

    Galvão Braga, Carlos; Ribeiro, Sílvia; Martins, Juliana; Arantes, Carina; Ramos, Vítor; Primo, João; Magalhães, Sónia; Correia, Adelino

    2014-04-01

    Pheochromocytoma is a rare catecholamine-producing tumor, discovered incidentally in 50% of cases. We present the case of a 44-year-old male with a history of paroxysmal palpitations. Baseline ECG, transthoracic echocardiogram and ECG stress test showed no relevant alterations. Paroxysmal atrial fibrillation was detected on 24-hour Holter ECG. After antiarrhythmic therapy, the patient remained symptomatic, and was accordingly referred for electrophysiological study and atrial fibrillation ablation. Anticoagulation was initiated before the procedure. After ablation and still anticoagulated, he complained of hematospermia. The abdominal and pelvic imaging study showed a 10-cm left adrenal mass, predominantly cystic, compatible with pheochromocytoma, which was confirmed after biochemical tests (increased urine metanephrines and plasma catecholamines). Metaiodobenzylguanidine scintigraphy scanning confirmed localized disease in the adrenal gland, excluding other uptake foci. Following appropriate preoperative management, surgical resection of the giant mass was performed successfully and without complications. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  9. Accuracy of ECG interpretation in competitive athletes: the impact of using standised ECG criteria.

    PubMed

    Drezner, Jonathan A; Asif, Irfan M; Owens, David S; Prutkin, Jordan M; Salerno, Jack C; Fean, Robyn; Rao, Ashwin L; Stout, Karen; Harmon, Kimberly G

    2012-04-01

    Interpretation of ECGs in athletes is complicated by physiological changes related to training. The purpose of this study was to determine the accuracy of ECG interpretation in athletes among different physician specialties, with and without use of a standised ECG criteria tool. Physicians were asked to interpret 40 ECGs (28 normal ECGs from college athletes randomised with 12 abnormal ECGs from individuals with known ciovascular pathology) and classify each ECG as (1) 'normal or variant--no further evaluation and testing needed' or (2) 'abnormal--further evaluation and testing needed.' After reading the ECGs, participants received a two-page ECG criteria tool to guide interpretation of the ECGs again. A total of 60 physicians participated: 22 primary care (PC) residents, 16 PC attending physicians, 12 sports medicine (SM) physicians and 10 ciologists. At baseline, the total number of ECGs correctly interpreted was PC residents 73%, PC attendings 73%, SM physicians 78% and ciologists 85%. With use of the ECG criteria tool, all physician groups significantly improved their accuracy (p<0.0001): PC residents 92%, PC attendings 90%, SM physicians 91% and ciologists 96%. With use of the ECG criteria tool, specificity improved from 70% to 91%, sensitivity improved from 89% to 94% and there was no difference comparing ciologists versus all other physicians (p=0.053). Providing standised criteria to assist ECG interpretation in athletes significantly improves the ability to accurately distinguish normal from abnormal findings across physician specialties, even in physicians with little or no experience.

  10. Comparison of HRV parameters derived from photoplethysmography and electrocardiography signals.

    PubMed

    Jeyhani, Vala; Mahdiani, Shadi; Peltokangas, Mikko; Vehkaoja, Antti

    2015-01-01

    Heart rate variability (HRV) has become a useful tool in analysis of cardiovascular system in both research and clinical fields. HRV has been also used in other applications such as stress level estimation in wearable devices. HRV is normally obtained from ECG as the time interval of two successive R waves. Recently PPG has been proposed as an alternative for ECG in HRV analysis to overcome some difficulties in measurement of ECG. In addition, PPG-HRV is also used in some commercial devices such as modern optical wrist-worn heart rate monitors. However, some researches have shown that PPG is not a surrogate for heart rate variability analysis. In this work, HRV analysis was applied on beat-to-beat intervals obtained from ECG and PPG in 19 healthy male subjects. Some important HRV parameters were calculated from PPG-HRV and ECG-HRV. Maximum of PPG and its second derivative were considered as two methods for obtaining the beat-to-beat signals from PPG and the results were compared with those achieved from ECG-HRV. Our results show that the smallest error happens in SDNN and SD2 with relative error of 2.46% and 2%, respectively. The most affected parameter is pNN50 with relative error of 29.89%. In addition, in our trial, using the maximum of PPG gave better results than its second derivative.

  11. Toward Improving Electrocardiogram (ECG) Biometric Verification using Mobile Sensors: A Two-Stage Classifier Approach

    PubMed Central

    Tan, Robin; Perkowski, Marek

    2017-01-01

    Electrocardiogram (ECG) signals sensed from mobile devices pertain the potential for biometric identity recognition applicable in remote access control systems where enhanced data security is demanding. In this study, we propose a new algorithm that consists of a two-stage classifier combining random forest and wavelet distance measure through a probabilistic threshold schema, to improve the effectiveness and robustness of a biometric recognition system using ECG data acquired from a biosensor integrated into mobile devices. The proposed algorithm is evaluated using a mixed dataset from 184 subjects under different health conditions. The proposed two-stage classifier achieves a total of 99.52% subject verification accuracy, better than the 98.33% accuracy from random forest alone and 96.31% accuracy from wavelet distance measure algorithm alone. These results demonstrate the superiority of the proposed algorithm for biometric identification, hence supporting its practicality in areas such as cloud data security, cyber-security or remote healthcare systems. PMID:28230745

  12. Toward Improving Electrocardiogram (ECG) Biometric Verification using Mobile Sensors: A Two-Stage Classifier Approach.

    PubMed

    Tan, Robin; Perkowski, Marek

    2017-02-20

    Electrocardiogram (ECG) signals sensed from mobile devices pertain the potential for biometric identity recognition applicable in remote access control systems where enhanced data security is demanding. In this study, we propose a new algorithm that consists of a two-stage classifier combining random forest and wavelet distance measure through a probabilistic threshold schema, to improve the effectiveness and robustness of a biometric recognition system using ECG data acquired from a biosensor integrated into mobile devices. The proposed algorithm is evaluated using a mixed dataset from 184 subjects under different health conditions. The proposed two-stage classifier achieves a total of 99.52% subject verification accuracy, better than the 98.33% accuracy from random forest alone and 96.31% accuracy from wavelet distance measure algorithm alone. These results demonstrate the superiority of the proposed algorithm for biometric identification, hence supporting its practicality in areas such as cloud data security, cyber-security or remote healthcare systems.

  13. Diagnostic accuracy of a smartphone electrocardiograph in dogs: Comparison with standard 6-lead electrocardiography.

    PubMed

    Vezzosi, T; Buralli, C; Marchesotti, F; Porporato, F; Tognetti, R; Zini, E; Domenech, O

    2016-10-01

    The diagnostic accuracy of a smartphone electrocardiograph (ECG) in evaluating heart rhythm and ECG measurements was evaluated in 166 dogs. A standard 6-lead ECG was acquired for 1 min in each dog. A smartphone ECG tracing was simultaneously recorded using a single-lead bipolar ECG recorder. All ECGs were reviewed by one blinded operator, who judged if tracings were acceptable for interpretation and assigned an electrocardiographic diagnosis. Agreement between smartphone and standard ECG in the interpretation of tracings was evaluated. Sensitivity and specificity for the detection of arrhythmia were calculated for the smartphone ECG. Smartphone ECG tracings were interpretable in 162/166 (97.6%) tracings. A perfect agreement between the smartphone and standard ECG was found in detecting bradycardia, tachycardia, ectopic beats and atrioventricular blocks. A very good agreement was found in detecting sinus rhythm versus non-sinus rhythm (100% sensitivity and 97.9% specificity). The smartphone ECG provided tracings that were adequate for analysis in most dogs, with an accurate assessment of heart rate, rhythm and common arrhythmias. The smartphone ECG represents an additional tool in the diagnosis of arrhythmias in dogs, but is not a substitute for a 6-lead ECG. Arrhythmias identified by the smartphone ECG should be followed up with a standard ECG before making clinical decisions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Novel Tool for Complete Digitization of Paper Electrocardiography Data.

    PubMed

    Ravichandran, Lakshminarayan; Harless, Chris; Shah, Amit J; Wick, Carson A; Mcclellan, James H; Tridandapani, Srini

    We present a Matlab-based tool to convert electrocardiography (ECG) information from paper charts into digital ECG signals. The tool can be used for long-term retrospective studies of cardiac patients to study the evolving features with prognostic value. To perform the conversion, we: 1) detect the graphical grid on ECG charts using grayscale thresholding; 2) digitize the ECG signal based on its contour using a column-wise pixel scan; and 3) use template-based optical character recognition to extract patient demographic information from the paper ECG in order to interface the data with the patients' medical record. To validate the digitization technique: 1) correlation between the digital signals and signals digitized from paper ECG are performed and 2) clinically significant ECG parameters are measured and compared from both the paper-based ECG signals and the digitized ECG. The validation demonstrates a correlation value of 0.85-0.9 between the digital ECG signal and the signal digitized from the paper ECG. There is a high correlation in the clinical parameters between the ECG information from the paper charts and digitized signal, with intra-observer and inter-observer correlations of 0.8-0.9 (p < 0.05), and kappa statistics ranging from 0.85 (inter-observer) to 1.00 (intra-observer). The important features of the ECG signal, especially the QRST complex and the associated intervals, are preserved by obtaining the contour from the paper ECG. The differences between the measures of clinically important features extracted from the original signal and the reconstructed signal are insignificant, thus highlighting the accuracy of this technique. Using this type of ECG digitization tool to carry out retrospective studies on large databases, which rely on paper ECG records, studies of emerging ECG features can be performed. In addition, this tool can be used to potentially integrate digitized ECG information with digital ECG analysis programs and with the patient's electronic medical record.

  15. An augmented magnetic navigation system for Transcatheter Aortic Valve Implantation.

    PubMed

    Luo, Zhe; Cai, Junfeng; Nie, Yuanyuan; Wang, Guotai; Gu, Lixu

    2013-01-01

    This research proposes an augmented magnetic navigation system for Transcatheter Aortic Valve Implantation (TAVI) employing a magnetic tracking system (MTS) combined with a dynamic aortic model and intra-operative ultrasound (US) images. The dynamic 3D aortic model is constructed based on the preoperative 4D computed tomography (CT), which is animated according to the real time electrocardiograph (ECG) input of patient. And a preoperative planning is performed to determine the target position of the aortic valve prosthesis. The temporal alignment is performed to synchronize the ECG signals, intra-operative US image and tracking information. Afterwards, with the assistance of synchronized ECG signals, the contour of aortic root automatic extracted from short axis US image is registered to the dynamic aortic model by a feature based registration intra-operatively. Then the augmented MTS guides the interventionist to confidently position and deploy the aortic valve prosthesis to target. The system was validated by animal studies on three porcine subjects, the deployment and tilting errors of which are 3.17 ± 0.91 mm and 7.40 ± 2.89° respectively.

  16. Development of Novel Non-Contact Electrodes for Mobile Electrocardiogram Monitoring System

    PubMed Central

    Chou, Willy; Wang, Hsing-Yu; Huang, Yan-Jun; Pan, Jeng-Shyang

    2013-01-01

    Real-time monitoring of cardiac health is helpful for patients with cardiovascular disease. Many telemedicine systems based on ubiquitous computing and communication techniques have been proposed for monitoring the user's electrocardiogram (ECG) anywhere and anytime. Usually, wet electrodes are used in these telemedicine systems. However, wet electrodes require conduction gels and skin preparation that can be inconvenient and uncomfortable for users. In order to overcome this issue, a new non-contact electrode circuit was proposed and applied in developing a mobile electrocardiogram monitoring system. The proposed non-contact electrode can measure bio-potentials across thin clothing, allowing it to be embedded in a user's normal clothing to monitor ECG in daily life. We attempted to simplify the design of these non-contact electrodes to reduce power consumption while continuing to provide good signal quality. The electrical specifications and the performance of monitoring arrhythmia in clinical settings were also validated to investigate the reliability of the proposed design. Experimental results show that the proposed non-contact electrode provides good signal quality for measuring ECG across thin clothes. PMID:27170853

  17. Privacy-Preserving Electrocardiogram Monitoring for Intelligent Arrhythmia Detection.

    PubMed

    Son, Junggab; Park, Juyoung; Oh, Heekuck; Bhuiyan, Md Zakirul Alam; Hur, Junbeom; Kang, Kyungtae

    2017-06-12

    Long-term electrocardiogram (ECG) monitoring, as a representative application of cyber-physical systems, facilitates the early detection of arrhythmia. A considerable number of previous studies has explored monitoring techniques and the automated analysis of sensing data. However, ensuring patient privacy or confidentiality has not been a primary concern in ECG monitoring. First, we propose an intelligent heart monitoring system, which involves a patient-worn ECG sensor (e.g., a smartphone) and a remote monitoring station, as well as a decision support server that interconnects these components. The decision support server analyzes the heart activity, using the Pan-Tompkins algorithm to detect heartbeats and a decision tree to classify them. Our system protects sensing data and user privacy, which is an essential attribute of dependability, by adopting signal scrambling and anonymous identity schemes. We also employ a public key cryptosystem to enable secure communication between the entities. Simulations using data from the MIT-BIH arrhythmia database demonstrate that our system achieves a 95.74% success rate in heartbeat detection and almost a 96.63% accuracy in heartbeat classification, while successfully preserving privacy and securing communications among the involved entities.

  18. Privacy-Preserving Electrocardiogram Monitoring for Intelligent Arrhythmia Detection †

    PubMed Central

    Son, Junggab; Park, Juyoung; Oh, Heekuck; Bhuiyan, Md Zakirul Alam; Hur, Junbeom; Kang, Kyungtae

    2017-01-01

    Long-term electrocardiogram (ECG) monitoring, as a representative application of cyber-physical systems, facilitates the early detection of arrhythmia. A considerable number of previous studies has explored monitoring techniques and the automated analysis of sensing data. However, ensuring patient privacy or confidentiality has not been a primary concern in ECG monitoring. First, we propose an intelligent heart monitoring system, which involves a patient-worn ECG sensor (e.g., a smartphone) and a remote monitoring station, as well as a decision support server that interconnects these components. The decision support server analyzes the heart activity, using the Pan–Tompkins algorithm to detect heartbeats and a decision tree to classify them. Our system protects sensing data and user privacy, which is an essential attribute of dependability, by adopting signal scrambling and anonymous identity schemes. We also employ a public key cryptosystem to enable secure communication between the entities. Simulations using data from the MIT-BIH arrhythmia database demonstrate that our system achieves a 95.74% success rate in heartbeat detection and almost a 96.63% accuracy in heartbeat classification, while successfully preserving privacy and securing communications among the involved entities. PMID:28604628

  19. Is 50 Hz high enough ECG sampling frequency for accurate HRV analysis?

    PubMed

    Mahdiani, Shadi; Jeyhani, Vala; Peltokangas, Mikko; Vehkaoja, Antti

    2015-01-01

    With the worldwide growth of mobile wireless technologies, healthcare services can be provided at anytime and anywhere. Usage of wearable wireless physiological monitoring system has been extensively increasing during the last decade. These mobile devices can continuously measure e.g. the heart activity and wirelessly transfer the data to the mobile phone of the patient. One of the significant restrictions for these devices is usage of energy, which leads to requiring low sampling rate. This article is presented in order to investigate the lowest adequate sampling frequency of ECG signal, for achieving accurate enough time domain heart rate variability (HRV) parameters. For this purpose the ECG signals originally measured with high 5 kHz sampling rate were down-sampled to simulate the measurement with lower sampling rate. Down-sampling loses information, decreases temporal accuracy, which was then restored by interpolating the signals to their original sampling rates. The HRV parameters obtained from the ECG signals with lower sampling rates were compared. The results represent that even when the sampling rate of ECG signal is equal to 50 Hz, the HRV parameters are almost accurate with a reasonable error.

  20. Temporal abstraction and inductive logic programming for arrhythmia recognition from electrocardiograms.

    PubMed

    Carrault, G; Cordier, M-O; Quiniou, R; Wang, F

    2003-07-01

    This paper proposes a novel approach to cardiac arrhythmia recognition from electrocardiograms (ECGs). ECGs record the electrical activity of the heart and are used to diagnose many heart disorders. The numerical ECG is first temporally abstracted into series of time-stamped events. Temporal abstraction makes use of artificial neural networks to extract interesting waves and their features from the input signals. A temporal reasoner called a chronicle recogniser processes such series in order to discover temporal patterns called chronicles which can be related to cardiac arrhythmias. Generally, it is difficult to elicit an accurate set of chronicles from a doctor. Thus, we propose to learn automatically from symbolic ECG examples the chronicles discriminating the arrhythmias belonging to some specific subset. Since temporal relationships are of major importance, inductive logic programming (ILP) is the tool of choice as it enables first-order relational learning. The approach has been evaluated on real ECGs taken from the MIT-BIH database. The performance of the different modules as well as the efficiency of the whole system is presented. The results are rather good and demonstrate that integrating numerical techniques for low level perception and symbolic techniques for high level classification is very valuable.

  1. Architecture design of the multi-functional wavelet-based ECG microprocessor for realtime detection of abnormal cardiac events.

    PubMed

    Cheng, Li-Fang; Chen, Tung-Chien; Chen, Liang-Gee

    2012-01-01

    Most of the abnormal cardiac events such as myocardial ischemia, acute myocardial infarction (AMI) and fatal arrhythmia can be diagnosed through continuous electrocardiogram (ECG) analysis. According to recent clinical research, early detection and alarming of such cardiac events can reduce the time delay to the hospital, and the clinical outcomes of these individuals can be greatly improved. Therefore, it would be helpful if there is a long-term ECG monitoring system with the ability to identify abnormal cardiac events and provide realtime warning for the users. The combination of the wireless body area sensor network (BASN) and the on-sensor ECG processor is a possible solution for this application. In this paper, we aim to design and implement a digital signal processor that is suitable for continuous ECG monitoring and alarming based on the continuous wavelet transform (CWT) through the proposed architectures--using both programmable RISC processor and application specific integrated circuits (ASIC) for performance optimization. According to the implementation results, the power consumption of the proposed processor integrated with an ASIC for CWT computation is only 79.4 mW. Compared with the single-RISC processor, about 91.6% of the power reduction is achieved.

  2. Preliminary results from BCG and ECG measurements in the heart failure clinic.

    PubMed

    Giovangrandi, Laurent; Inan, Omer T; Banerjee, Dipanjan; Kovacs, Gregory T A

    2012-01-01

    We report on the preliminary deployment of a bathroom scale-based ballistocardiogram (BCG) system for the in-hospital monitoring of patients with heart failure. These early trials provided valuable insights into the challenges and opportunities for such monitoring. In particular, the need for robust algorithms and adapted BCG metric is suggested. The system was designed to be robust and user-friendly, with dual ballistocardiogram (BCG) and electrocardiogram (ECG) capabilities. The BCG was measured from a modified bathroom scale, while the ECG (used as timing reference) was measured using dry handlebar electrodes. The signal conditioning and digitization circuits were USB-powered, and data acquisition performed using a netbook. Four patients with a NYHA class III at admission were measured daily for the duration of their treatment at Stanford hospital. A measure of BCG quality, in essence a quantitative implementation of the BCG classes originally defined in the 1950s, is proposed as a practical parameter.

  3. Telefetalcare: a first prototype of a wearable fetal electrocardiograph.

    PubMed

    Fanelli, A; Signorini, M G; Ferrario, M; Perego, P; Piccini, L; Andreoni, G; Magenes, G

    2011-01-01

    Fetal heart rate monitoring is fundamental to infer information about fetal health state during pregnancy. The cardiotocography (CTG) is the most common antepartum monitoring technique. Abdominal ECG recording represents the most valuable alternative to cardiotocography, as it allows passive, non invasive and long term fetal monitoring. Unluckily fetal ECG has low SNR and needs to be extracted from abdominal recordings using ad hoc algorithms. This work describes a prototype of a wearable fetal ECG electrocardiograph. The system has flat band frequency response between 1-60 Hz and guarantees good signal quality. It was tested on pregnant women between the 30(th) and 34(th) gestational week. Several electrodes configurations were tested, in order to identify the best solution. Implementation of a simple algorithm for FECG extraction permitted the reliable detection of maternal and fetal QRS complexes. The system will allow continuative and deep screening of fetal heart rate, introducing the possibility of home fetal monitoring.

  4. Prehospital telemedicine electrocardiogram triage for a regional public emergency medical service: is it worth it? A preliminary cost analysis.

    PubMed

    Brunetti, Natale Daniele; Dellegrottaglie, Giulia; Lopriore, Claudio; Di Giuseppe, Giuseppe; De Gennaro, Luisa; Lanzone, Saverio; Di Biase, Matteo

    2014-03-01

    Telemedicine has been shown to improve quality of health-care delivery in several fields of medicine; its cost-effectiveness, however, is still a matter of debate. Pre-hospital telemedicine electrocardiogram triage for regional public emergency medical service may reduce costs. An economic evaluation (cost analysis) was performed from the perspective of regional health-care system. Patients enrolled in the study and considered for cost analysis were those who called the local emergency medical service (EMS; dialing 1-1-8) during 2012 and underwent prehospital field triage with a telemedicine electrocardiogram (ECG) in the case of suspected acute cardiac disease (acute coronary syndrome, arrhythmia). The prehospital ECGs were read by a remote cardiologist, available 24/7. Cost savings associated with this method were calculated by subtracting the cost of prehospital triage with telemedicine support from the cost of conventional emergency department triage (ECG and consultation by a cardiologist). During 2012, the regional EMS performed 109 750 ECGs by telemedicine support. The associated total cost for the regional health-care system was €1 833 333, with a €16.70 cost per single ECG/consultation. Given the cost of similar conventional emergency department treatment from a regional rate list of €24.80 to €55.20, the savings was €8.10 to €38.40 per ECG/consultation (total savings, €891 759.50 to €4 219 379.50). The cost for ruling out an acute cardiac disease was €25.30; for a prehospital diagnosis of cardiovascular disease, €49.20. With 629 prehospital diagnoses of ST-elevation myocardial infarction and reported reductions in mortality thanks to prehospital diagnosis deduced from prior studies, 69 lives per year presumably could be saved, with a cost per quality-adjusted life year gained of €1927, €990/€ - 2508 after correction for potential savings. Prehospital EMS triage with telemedicine ECG in patients with suspected acute cardiac disease may reduce health-care costs. © 2014 Wiley Periodicals, Inc.

  5. Troponin T or troponin I or CK-MB (or none?).

    PubMed

    Collinson, P O

    1998-11-01

    Differential diagnosis of patients who present with chest pain remains problematical. It has been shown that 11.8-7% of patients with acute myocardial infarction (AMI) are sent home from the emergency department (ED). Audit of our own ED has shown the incidence of missed prognostically significant myocardial damage to be 6.7%. Diagnostic criteria for AMI have classically been based on the triad of history, ECG and measurement of cardiac enzymes. The choice of 'cardiac enzymes' has been dictated by the evolution of laboratory techniques, commencing with measurement of aspartate transaminase and progressing to measurement of creatine kinase (CK) and its MB isoenzyme (CK-MB). Measurement of CK-MB has been shown by both clinical studies and rigorous statistical analysis to represent the best test for the diagnosis of AMI. The advent of real time immunoassay together with advances in therapeutic options for management of acute coronary syndromes (ACS) has resulted in a paradigm shift in the approach to laboratory testing. Immunoassay for CK-MB (CK-MB mass measurement) is diagnostically superior to CK-MB activity measurement and is the test of choice for 'classical' AMI. Development of immunoassays for the cardiac troponins, i.e. cardiac troponin T (cTnT) and cardiac troponin I (cTnI), has enhanced diagnostic specificity. These measurements are completely specific for cardiac damage, allow quantitation of the extent of infarction and are diagnostically superior to CK-MB measurement. Applications of this specificity have included the differential diagnosis of CK elevation in arduous physical training, detection of myocardial damage after DC cardioversion and prediction of ejection fraction. Of more interest is the utility of these markers in management of patients presenting without clear electrocardiographic changes. Diagnosis and management of patients presenting with ST segment elevation has been clarified by large clinical trials of thrombolytic agents. In such patients, thrombolysis is the treatment of choice. Patients presenting with ST segment elevation represents the minority of patients with probable ACS 9.6% of all patients presenting to our hospital. The majority require risk stratification into high- and low-risk groups. It is here that cardiac troponins have a major role. The measurement of cTnT has been shown in a large number of studies to enable risk stratification of patients with unstable angina. The combination of cTnT, admission ECG and stress ECG can be used for a comprehensive risk stratification of patients with unstable angina. The combination of cTnT, admission ECG and stress ECG can be used for a comprehensive risk stratification which can be completed by 24 h from admission, as well as allowing a safe discharge policy from the ED. Measurements of cardiac troponins can also be used to predict prognosis in patients with other diagnostic categories. Patients with cardiac failure can be risk stratified according to cTnT status. cTnT status on admission allows subdivision into high- and low-risk groups in patients presenting with ST segment elevation. Certainly, cTnT measurement can be incorporated into a clinical decision-making strategy to assign patients to investigation and management pathways. There is evidence that cTnT may be useful to guide therapeutic options. The major issue is one of cost. In the U.K. model of managed care with undemanding diagnostic standards, the role of cTnT will be to enhance clinical decision-making strategies, to provide accurate diagnosis and to reduce lengths of stay. This can be shown to have potential for major improvements in cost efficiency. Improvements in diagnostic accuracy can reduce inappropriate long-term drug therapy. In systems with a more aggressive laboratory investigation strategy, rationalization of test numbers will provide an immediate cost reduction while improving quality. Finally, use of point-of-care testing (POCT) means that biochemical testing can be pe

  6. A Hybrid Approach to Detect Driver Drowsiness Utilizing Physiological Signals to Improve System Performance and Wearability

    PubMed Central

    Badruddin, Nasreen

    2017-01-01

    Driver drowsiness is a major cause of fatal accidents, injury, and property damage, and has become an area of substantial research attention in recent years. The present study proposes a method to detect drowsiness in drivers which integrates features of electrocardiography (ECG) and electroencephalography (EEG) to improve detection performance. The study measures differences between the alert and drowsy states from physiological data collected from 22 healthy subjects in a driving simulator-based study. A monotonous driving environment is used to induce drowsiness in the participants. Various time and frequency domain feature were extracted from EEG including time domain statistical descriptors, complexity measures and power spectral measures. Features extracted from the ECG signal included heart rate (HR) and heart rate variability (HRV), including low frequency (LF), high frequency (HF) and LF/HF ratio. Furthermore, subjective sleepiness scale is also assessed to study its relationship with drowsiness. We used paired t-tests to select only statistically significant features (p < 0.05), that can differentiate between the alert and drowsy states effectively. Significant features of both modalities (EEG and ECG) are then combined to investigate the improvement in performance using support vector machine (SVM) classifier. The other main contribution of this paper is the study on channel reduction and its impact to the performance of detection. The proposed method demonstrated that combining EEG and ECG has improved the system’s performance in discriminating between alert and drowsy states, instead of using them alone. Our channel reduction analysis revealed that an acceptable level of accuracy (80%) could be achieved by combining just two electrodes (one EEG and one ECG), indicating the feasibility of a system with improved wearability compared with existing systems involving many electrodes. Overall, our results demonstrate that the proposed method can be a viable solution for a practical driver drowsiness system that is both accurate and comfortable to wear. PMID:28858220

  7. Abnormalities of the QT interval in primary disorders of autonomic failure.

    PubMed

    Choy, A M; Lang, C C; Roden, D M; Robertson, D; Wood, A J; Robertson, R M; Biaggioni, I

    1998-10-01

    Experimental evidence shows that activation of the autonomic nervous system influences ventricular repolarization and, therefore, the QT interval on the ECG. To test the hypothesis that the QT interval is abnormal in autonomic dysfunction, we examined ECGs in patients with severe primary autonomic failure and in patients with congenital dopamine beta-hydroxylase (DbetaH) deficiency who are unable to synthesize norepinephrine and epinephrine. Maximal QT and rate-corrected QT (QTc) intervals and adjusted QTc dispersion [(maximal QTc - minimum QTc on 12 lead ECG)/square root of the number of leads measured] were determined in blinded fashion from ECGs of 67 patients with primary autonomic failure (36 patients with multiple system atrophy [MSA], and 31 patients with pure autonomic failure [PAF]) and 17 age- and sex-matched healthy controls. ECGs of 5 patients with congenital DbetaH deficiency and 6 age- and sex-matched controls were also analyzed. Patients with MSA and PAF had significantly prolonged maximum QTc intervals (492+/-58 ms(1/2) and 502+/-61 ms(1/2) [mean +/- SD]), respectively, compared with controls (450+/-18 ms(1/2), P < .05 and P < .01, respectively). A similar but not significant trend was observed for QT. QTc dispersion was also increased in MSA (40+/-20 ms(1/2), P < .05 vs controls) and PAF patients (32+/-19 ms(1/2), NS) compared with controls (21+/-5 ms(1/2)). In contrast, patients with congenital DbetaH deficiency did not have significantly different RR, QT, QTc intervals, or QTc dispersion when compared with controls. Patients with primary autonomic failure who have combined parasympathetic and sympathetic failure have abnormally prolonged QT interval and increased QT dispersion. However, QT interval in patients with congenital DbetaH deficiency was not significantly different from controls. It is possible, therefore, that QT abnormalities in patients with primary autonomic failure are not solely caused by lesions of the sympathetic nervous system, and that the parasympathetic nervous system is likely to have a modulatory role in ventricular repolarization.

  8. Smartphone transmission of electrocardiography images to reduce time of cardiac catheterization laboratory activation.

    PubMed

    Chao, Chun-Chieh; Chen, Yi-Chun; Shih, Chun-Ming; Hou, Sen-Kuang; Seethala, Raghu R; Aisiku, Imoigele P; Huang, Chuan-Chin; Hou, Peter C; Kao, Wei-Fong

    2018-06-01

    This retrospective study evaluated the use of a smartphone application to facilitate communication between the emergency physician (EP) and the interventional cardiologist in order to minimize the time to cardiac catheterization laboratory (CCL) activation and time to percutaneous coronary intervention (PCI). We retrospectively collected pertinent time-points in the management of patients diagnosed with STEMI in the emergency department and their outcome. The primary outcome was the reduction in the time from ECG interpretation to CCL activation after the implementation of a smartphone application. A total of 84 patients were enrolled. Patients' electrocardiography (ECG) were described by traditional verbal communication via telephone (group 1, n = 40) and by additional smartphone transmission of ECG images to an interventional cardiologist (group 2, n = 44). Relevant time-points were recorded for analysis. The time from ECG interpretation to CCL activation was reduced from 28.3 ± 4.1 in group 1 to 17.6 ± 2.3 min in group 2 (p = 0.03). Similarly, the time from ECG interpretation to balloon inflation time (D2B) decreased from 93.1 to 73.4 min (p = 0.025). Comparing group 2 with group 1, the door to balloon (D2B) time improved to 90.4 ± 9.8 from 119.3 ± 16.3 min (p = 0.23), the proportion of patients with a D2B time less than 90 min increased to 70.5% from 52.5% (p = 0.09), and the mortality rate decreased to 2.2% from 12.5% (p = 0.07). The additional use of a smartphone application to transmit ECG information to interventional cardiologists by EPs facilitated communication and reduced the decision time to CCL activation and percutaneous intervention. Copyright © 2017. Published by Elsevier Taiwan LLC.

  9. Identifying postoperative atrial fibrillation in cardiac surgical patients posthospital discharge, using iPhone ECG: a study protocol

    PubMed Central

    Lowres, Nicole; Freedman, S Ben; Gallagher, Robyn; Kirkness, Ann; Marshman, David; Orchard, Jessica; Neubeck, Lis

    2015-01-01

    Introduction Postoperative atrial fibrillation (AF) occurs in 30–40% of patients after cardiac surgery. Identification of recurrent postoperative AF is required to initiate evidence-based management to reduce the risk of subsequent stroke. However, as AF is often asymptomatic, recurrences may not be detected after discharge. This study determines feasibility and impact of a self-surveillance programme to identify recurrence of postoperative AF in the month of posthospital discharge. Methods and analysis This is a feasibility study, using a cross-sectional study design, of self-screening for AF using a hand-held single-lead iPhone electrocardiograph device (iECG). Participants will be recruited from the cardiothoracic surgery wards of the Royal North Shore Hospital and North Shore Private Hospital, Sydney, Australia. Cardiac surgery patients admitted in sinus rhythm and experiencing a transient episode of postoperative AF will be eligible for recruitment. Participants will be taught to take daily ECG recordings for 1 month posthospital discharge using the iECG and will be provided education regarding AF, including symptoms and health risks. The primary outcome is the feasibility of patient self-monitoring for AF recurrence using an iECG. Secondary outcomes include proportion of patients identified with recurrent AF; estimation of stroke risk and patient knowledge. Process outcomes and qualitative data related to acceptability of patient's use of the iECG and sustainability of the screening programme beyond the trial setting will also be collected. Ethics and dissemination Primary ethics approval was received on 25 February 2014 from Northern Sydney Local Health District Human Resource Ethics Committee, and on 17 July 2014 from North Shore Private Hospital Ethics Committee. Results will be disseminated via forums including, but not limited to, peer-reviewed publications and presentation at national and international conferences. Trial registration number ACTRN12614000383662. PMID:25586373

  10. Identifying postoperative atrial fibrillation in cardiac surgical patients posthospital discharge, using iPhone ECG: a study protocol.

    PubMed

    Lowres, Nicole; Freedman, S Ben; Gallagher, Robyn; Kirkness, Ann; Marshman, David; Orchard, Jessica; Neubeck, Lis

    2015-01-13

    Postoperative atrial fibrillation (AF) occurs in 30-40% of patients after cardiac surgery. Identification of recurrent postoperative AF is required to initiate evidence-based management to reduce the risk of subsequent stroke. However, as AF is often asymptomatic, recurrences may not be detected after discharge. This study determines feasibility and impact of a self-surveillance programme to identify recurrence of postoperative AF in the month of posthospital discharge. This is a feasibility study, using a cross-sectional study design, of self-screening for AF using a hand-held single-lead iPhone electrocardiograph device (iECG). Participants will be recruited from the cardiothoracic surgery wards of the Royal North Shore Hospital and North Shore Private Hospital, Sydney, Australia. Cardiac surgery patients admitted in sinus rhythm and experiencing a transient episode of postoperative AF will be eligible for recruitment. Participants will be taught to take daily ECG recordings for 1 month posthospital discharge using the iECG and will be provided education regarding AF, including symptoms and health risks. The primary outcome is the feasibility of patient self-monitoring for AF recurrence using an iECG. Secondary outcomes include proportion of patients identified with recurrent AF; estimation of stroke risk and patient knowledge. Process outcomes and qualitative data related to acceptability of patient's use of the iECG and sustainability of the screening programme beyond the trial setting will also be collected. Primary ethics approval was received on 25 February 2014 from Northern Sydney Local Health District Human Resource Ethics Committee, and on 17 July 2014 from North Shore Private Hospital Ethics Committee. Results will be disseminated via forums including, but not limited to, peer-reviewed publications and presentation at national and international conferences. ACTRN12614000383662. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Prognostic value of dynamic electrocardiographic T wave changes in non-ST elevation acute coronary syndrome.

    PubMed

    Sarak, Bradley; Goodman, Shaun G; Yan, Raymond T; Tan, Mary K; Steg, Ph Gabriel; Tan, Nigel S; Fox, Keith A A; Udell, Jacob A; Brieger, David; Welsh, Robert C; Gale, Chris P; Yan, Andrew T

    2016-09-01

    To assess the relationship between the evolution of T wave inversion (TWI) on the 24-48 h postadmission ECG and the patient characteristics, management and clinical outcomes among those with non-ST elevation acute coronary syndrome (NSTE-ACS). We evaluated admission and 24-48 h follow-up ECGs of 7201 patients with NSTE-ACS from the prospective, multicentre Global Registry of Acute Coronary Events (GRACE) and Canadian ACS Registry I. We performed multivariable analyses to determine the association between new TWI (on follow-up ECG only), resolved TWI (on admission ECG only) and persistent TWI (on both admission and follow-up ECG) and inhospital and cumulative 6-month all-cause mortality. Patients with TWI were older, more likely to have cardiovascular risk factors, higher Killip class and GRACE risk scores. After adjustment for known prognostic factors, compared with patients presenting without TWI, new TWI was associated with significantly lower inhospital mortality (OR=0.60, 95% CI 0.38 to 0.95, p=0.029), whereas resolved (OR=1.06, 95% CI 0.65 to 1.75, p=0.81) and persistent (OR=0.73, 95% CI 0.48 to 1.11, p=0.14) TWI did not predict inhospital mortality. No TWI pattern independently predicted inhospital adverse cardiovascular events or cumulative 6-month mortality. In contrast, ST depression on the admission and follow-up ECG were independent predictors of inhospital and 6-month mortality. Across the spectrum of NSTE-ACS, TWI within 48 h of presentation was associated with high-risk clinical features, but its presence or dynamic change did not provide additional prognostic value beyond other established clinical predictors. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Tele-electrocardiography in the epidemiological 'Study of Health in Pomerania' (SHIP).

    PubMed

    Alte, Dietrich; Völzke, Henry; Robinson, Daniel M; Kleine, Volker; Grabe, Hans Jörgen; John, Ulrich; Felix, Stephan B

    2006-01-01

    We have evaluated a portable electrocardiogram (ECG) card in the large population-based epidemiological 'Study of Health in Pomerania' (SHIP). In all, 7008 men and women (20-79 years) were randomly selected from population registries and 4310 subjects participated. Participants used an ECG card for four weeks and recorded two ECGs daily. The participants were also encouraged to record additional ECGs in the case of symptomatic arrhythmias, chest pain or dizziness. The ECGs were sent via telephone. Acrobat (.pdf) files arrived at the study centre via email. Arrhythmias were analysed by visual ECG inspection. Seventy-one per cent of the participants sent at least 80% of the requested ECGs for four weeks. There were few problems (about 70) in the total of 38,162 ECGs transmitted. Overall, 94% of all ECGs were rated as 'good'. Physicians required about 1.5 h to read approximately 100 ECGs daily. The functionality and ergonomics of ECG cards appear to be sufficiently developed for large-scale use in epidemiological studies.

  13. WaveformECG: A Platform for Visualizing, Annotating, and Analyzing ECG Data

    PubMed Central

    Winslow, Raimond L.; Granite, Stephen; Jurado, Christian

    2017-01-01

    The electrocardiogram (ECG) is the most commonly collected data in cardiovascular research because of the ease with which it can be measured and because changes in ECG waveforms reflect underlying aspects of heart disease. Accessed through a browser, WaveformECG is an open source platform supporting interactive analysis, visualization, and annotation of ECGs. PMID:28642673

  14. Stage call: Cardiovascular reactivity to audition stress in musicians

    PubMed Central

    Chanwimalueang, Theerasak; Aufegger, Lisa; Adjei, Tricia; Wasley, David; Cruder, Cinzia; Mandic, Danilo P.

    2017-01-01

    Auditioning is at the very center of educational and professional life in music and is associated with significant psychophysical demands. Knowledge of how these demands affect cardiovascular responses to psychosocial pressure is essential for developing strategies to both manage stress and understand optimal performance states. To this end, we recorded the electrocardiograms (ECGs) of 16 musicians (11 violinists and 5 flutists) before and during performances in both low- and high-stress conditions: with no audience and in front of an audition panel, respectively. The analysis consisted of the detection of R-peaks in the ECGs to extract heart rate variability (HRV) from the notoriously noisy real-world ECGs. Our data analysis approach spanned both standard (temporal and spectral) and advanced (structural complexity) techniques. The complexity science approaches—namely, multiscale sample entropy and multiscale fuzzy entropy—indicated a statistically significant decrease in structural complexity in HRV from the low- to the high-stress condition and an increase in structural complexity from the pre-performance to performance period, thus confirming the complexity loss theory and a loss in degrees of freedom due to stress. Results from the spectral analyses also suggest that the stress responses in the female participants were more parasympathetically driven than those of the male participants. In conclusion, our findings suggest that interventions to manage stress are best targeted at the sensitive pre-performance period, before an audition begins. PMID:28437466

  15. Novel Tool for Complete Digitization of Paper Electrocardiography Data

    PubMed Central

    Harless, Chris; Shah, Amit J.; Wick, Carson A.; Mcclellan, James H.

    2013-01-01

    Objective: We present a Matlab-based tool to convert electrocardiography (ECG) information from paper charts into digital ECG signals. The tool can be used for long-term retrospective studies of cardiac patients to study the evolving features with prognostic value. Methods and procedures: To perform the conversion, we: 1) detect the graphical grid on ECG charts using grayscale thresholding; 2) digitize the ECG signal based on its contour using a column-wise pixel scan; and 3) use template-based optical character recognition to extract patient demographic information from the paper ECG in order to interface the data with the patients' medical record. To validate the digitization technique: 1) correlation between the digital signals and signals digitized from paper ECG are performed and 2) clinically significant ECG parameters are measured and compared from both the paper-based ECG signals and the digitized ECG. Results: The validation demonstrates a correlation value of 0.85–0.9 between the digital ECG signal and the signal digitized from the paper ECG. There is a high correlation in the clinical parameters between the ECG information from the paper charts and digitized signal, with intra-observer and inter-observer correlations of 0.8–0.9 \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}$({\\rm p}<{0.05})$\\end{document}, and kappa statistics ranging from 0.85 (inter-observer) to 1.00 (intra-observer). Conclusion: The important features of the ECG signal, especially the QRST complex and the associated intervals, are preserved by obtaining the contour from the paper ECG. The differences between the measures of clinically important features extracted from the original signal and the reconstructed signal are insignificant, thus highlighting the accuracy of this technique. Clinical impact: Using this type of ECG digitization tool to carry out retrospective studies on large databases, which rely on paper ECG records, studies of emerging ECG features can be performed. In addition, this tool can be used to potentially integrate digitized ECG information with digital ECG analysis programs and with the patient's electronic medical record. PMID:26594601

  16. Is screening for abnormal ECG patterns justified in long-term follow-up of childhood cancer survivors treated with anthracyclines?

    PubMed

    Pourier, Milanthy S; Mavinkurve-Groothuis, Annelies M C; Loonen, Jacqueline; Bökkerink, Jos P M; Roeleveld, Nel; Beer, Gil; Bellersen, Louise; Kapusta, Livia

    2017-03-01

    ECG and echocardiography are noninvasive screening tools to detect subclinical cardiotoxicity in childhood cancer survivors (CCSs). Our aims were as follows: (1) assess the prevalence of abnormal ECG patterns, (2) determine the agreement between abnormal ECG patterns and echocardiographic abnormalities; and (3) determine whether ECG screening for subclinical cardiotoxicity in CCSs is justified. We retrospectively studied ECG and echocardiography in asymptomatic CCSs more than 5 years after anthracycline treatment. Exclusion criteria were abnormal ECG and/or echocardiogram at the start of therapy, incomplete follow-up data, clinical heart failure, cardiac medication, and congenital heart disease. ECG abnormalities were classified using the Minnesota Code. Level of agreement between ECG and echocardiography was calculated with Cohen kappa. We included 340 survivors with a mean follow-up of 14.5 years (range 5-32). ECG was abnormal in 73 survivors (21.5%), with ventricular conduction disorders, sinus bradycardia, and high-amplitude R waves being most common. Prolonged QTc (>0.45 msec) was found in two survivors, both with a cumulative anthracycline dose of 300 mg/m 2 or higher. Echocardiography showed abnormalities in 44 survivors (12.9%), mostly mild valvular abnormalities. The level of agreement between ECG and echocardiography was low (kappa 0.09). Male survivors more often had an abnormal ECG (corrected odds ratio: 3.00, 95% confidence interval: 1.68-5.37). Abnormal ECG patterns were present in 21% of asymptomatic long-term CCSs. Lack of agreement between abnormal ECG patterns and echocardiographic abnormalities may suggest that ECG is valuable in long-term follow-up of CCSs. However, it is not clear whether these abnormal ECG patterns will be clinically relevant. © 2016 Wiley Periodicals, Inc.

  17. Robust and Accurate Anomaly Detection in ECG Artifacts Using Time Series Motif Discovery

    PubMed Central

    Sivaraks, Haemwaan

    2015-01-01

    Electrocardiogram (ECG) anomaly detection is an important technique for detecting dissimilar heartbeats which helps identify abnormal ECGs before the diagnosis process. Currently available ECG anomaly detection methods, ranging from academic research to commercial ECG machines, still suffer from a high false alarm rate because these methods are not able to differentiate ECG artifacts from real ECG signal, especially, in ECG artifacts that are similar to ECG signals in terms of shape and/or frequency. The problem leads to high vigilance for physicians and misinterpretation risk for nonspecialists. Therefore, this work proposes a novel anomaly detection technique that is highly robust and accurate in the presence of ECG artifacts which can effectively reduce the false alarm rate. Expert knowledge from cardiologists and motif discovery technique is utilized in our design. In addition, every step of the algorithm conforms to the interpretation of cardiologists. Our method can be utilized to both single-lead ECGs and multilead ECGs. Our experiment results on real ECG datasets are interpreted and evaluated by cardiologists. Our proposed algorithm can mostly achieve 100% of accuracy on detection (AoD), sensitivity, specificity, and positive predictive value with 0% false alarm rate. The results demonstrate that our proposed method is highly accurate and robust to artifacts, compared with competitive anomaly detection methods. PMID:25688284

  18. Addition of the electrocardiogram to the preparticipation examination of college athletes.

    PubMed

    Le, Vy-Van; Wheeler, Matthew T; Mandic, Sandra; Dewey, Frederick; Fonda, Holly; Perez, Marco; Sungar, Gannon; Garza, Daniel; Ashley, Euan A; Matheson, Gordon; Froelicher, Victor

    2010-03-01

    Although the use of standardized cardiovascular (CV) system-focused history and physical examination is recommended for the preparticipation examination (PPE) of athletes, the addition of the electrocardiogram (ECG) has been controversial. Because the impact of ECG screening on college athletes has rarely been reported, we analyzed the findings of adding the ECG to the PPE of Stanford athletes. For the past 15 years, the Stanford Sports Medicine program has mandated a PPE questionnaire and physical examination by Stanford physicians for participation in intercollegiate athletics. In 2007, computerized ECGs with digital measurements were recorded on athletes and entered into a database. Although the use of standardized CV-focused history and physical examination are recommended for the PPE of athletes, the addition of the ECG has been controversial. Because the feasibility and outcomes of ECG screening on college athletes have rarely been reported, we present findings derived from the addition of the ECG to the PPE of Stanford athletes. For the past 15 years, the Stanford Sports Medicine program has mandated a PPE questionnaire and physical examination by Stanford physicians for participation in intercollegiate athletics. In 2007, computerized ECGs with digital measurements were recorded on athletes and entered into a database. Six hundred fifty-eight recordings were obtained (54% men, 10% African-American, mean age 20 years) representing 24 sports. Although 68% of the women had normal ECGs, only 38% of the men did so. Incomplete right bundle branch block (RBBB) (13%), right axis deviation (RAD) (10%), and atrial abnormalities (3%) were the 3 most common minor abnormalities. Sokolow-Lyon criteria for left ventricular hypertrophy (LVH) were found in 49%; however, only 27% had a Romhilt-Estes score of >or=4. T-wave inversion in V2 to V3 occurred in 7%, and only 5 men had abnormal Q-waves. Sixty-three athletes (10%) were judged to have distinctly abnormal ECG findings possibly associated with conditions including hypertrophic cardiomyopathy or arrhythmogenic right ventricular dysplasia/cardiomyopathy. These athletes were offered further testing but this was not mandated according to the research protocol. Six hundred fifty-three recordings were obtained (54% men, 7% African American, mean age 20 years), representing 24 sports. Although 68% of the women had normal ECGs, only 38% of the men did so. Incomplete RBBB (13%), RAD (10%), and atrial abnormalities (3%) were the 3 most common minor abnormalities. Sokolow-Lyon criteria for LVH were found in 49%; however, only 27% had a Romhilt-Estes score of >or=4. T-wave inversion in V2 to V3 occurred in 7% and only 5 men had abnormal Q-waves. Sixty-five athletes (10%) were judged to have distinctly abnormal ECG findings suggestive of arrhythmogenic right ventricular dysplasia, hypertrophic cardiomyopathy, and/or biventricular hypertrophy. These athletes will be submitted to further testing. Mass ECG screening is achievable within the collegiate setting by using volunteers when the appropriate equipment is available. However, the rate of secondary testing suggests the need for an evaluation of cost-effectiveness for mass screening and the development of new athlete-specific ECG interpretation algorithms.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xie, Xueqian; Greuter, Marcel J. W.; Groen, Jaap M.

    Purpose: Coronary artery calcium score, traditionally based on electrocardiography (ECG)-triggered computed tomography (CT), predicts cardiovascular risk. However, nontriggered CT is extensively utilized. The study-purpose is to evaluate the in vitro agreement in coronary calcium score between nontriggered thoracic CT and ECG-triggered cardiac CT.Methods: Three artificial coronary arteries containing calcifications of different densities (high, medium, and low), and sizes (large, medium, and small), were studied in a moving cardiac phantom. Two 64-detector CT systems were used. The phantom moved at 0–90 mm/s in nontriggered low-dose CT as index test, and at 0–30 mm/s in ECG-triggered CT as reference. Differences in calciummore » scores between nontriggered and ECG-triggered CT were analyzed by t-test and 95% confidence interval. The sensitivity to detect calcification was calculated as the percentage of positive calcium scores.Results: Overall, calcium scores in nontriggered CT were not significantly different to those in ECG-triggered CT (p > 0.05). Calcium scores in nontriggered CT were within the 95% confidence interval of calcium scores in ECG-triggered CT, except predominantly at higher velocities (≥50 mm/s) for the high-density and large-size calcifications. The sensitivity for a nonzero calcium score was 100% for large calcifications, but 46%± 11% for small calcifications in nontriggered CT.Conclusions: When performing multiple measurements, good agreement in positive calcium scores is found between nontriggered thoracic and ECG-triggered cardiac CT. Agreement decreases with increasing coronary velocity. From this phantom study, it can be concluded that a high calcium score can be detected by nontriggered CT, and thus, that nontriggered CT likely can identify individuals at high risk of cardiovascular disease. On the other hand, a zero calcium score in nontriggered CT does not reliably exclude coronary calcification.« less

  20. Effects of cuff inflation and deflation on pulse transit time measured from ECG and multi-wavelength PPG.

    PubMed

    Liu, Jing; Li, Yao; Ding, Xiao-Rong; Dai, Wen-Xuan; Zhang, Yuan-Ting

    2015-01-01

    Pulse transit time (PTT), which refers to the time it takes a pulse wave to travel between two arterial sites is a promising index for cuff-less blood pressure (BP) estimation, as well as non-invasive assessment of arterial functions. However, it has not been investigated whether PTTs measured from ECG and different wavelength PPG are equally affected by the arterial status. Furthermore, comparison between the changes of different PTTs can provide enlightenment on the hardware implementation of the PTT-based BP estimation method. This work mainly studied the changes of PTTs calculated from electrocardiogram (ECG) and multi-wavelength photoplethysmogram (PPG) after exerting cuff pressure on the upper arm. A four-channel PPG acquisition system was developed to collect the multi-wavelength PPG signals of red, yellow, green and blue light at the fingertip simultaneously. Ten subjects participated in the experiment and their PTTs measured from different PPG and ECG signals before and after exerting cuff pressure were compared. This study found that within one minute after the four-minute cuff inflation and deflation process, the PTT measured from ECG and yellow PPG experienced a significant increase (p<;0.05) while the PTT from ECG and blue PPG had no statistical difference (p>0.9) compared with that before exerting cuff pressure. This indicates that PTTs calculated from different wavelength PPG have different recoverability from smooth muscle relaxation. Another interesting finding is that the PTT calculated from ECG and yellow PPG had a strong correlation (|r|>0.7) with the time difference between yellow PPG and other PPG signals, which implies the potential of the time difference between yellow PPG and other PPGs as a complementary to PTT-based model for blood pressure estimation.

  1. Multiple ECG Fiducial Points-Based Random Binary Sequence Generation for Securing Wireless Body Area Networks.

    PubMed

    Zheng, Guanglou; Fang, Gengfa; Shankaran, Rajan; Orgun, Mehmet A; Zhou, Jie; Qiao, Li; Saleem, Kashif

    2017-05-01

    Generating random binary sequences (BSes) is a fundamental requirement in cryptography. A BS is a sequence of N bits, and each bit has a value of 0 or 1. For securing sensors within wireless body area networks (WBANs), electrocardiogram (ECG)-based BS generation methods have been widely investigated in which interpulse intervals (IPIs) from each heartbeat cycle are processed to produce BSes. Using these IPI-based methods to generate a 128-bit BS in real time normally takes around half a minute. In order to improve the time efficiency of such methods, this paper presents an ECG multiple fiducial-points based binary sequence generation (MFBSG) algorithm. The technique of discrete wavelet transforms is employed to detect arrival time of these fiducial points, such as P, Q, R, S, and T peaks. Time intervals between them, including RR, RQ, RS, RP, and RT intervals, are then calculated based on this arrival time, and are used as ECG features to generate random BSes with low latency. According to our analysis on real ECG data, these ECG feature values exhibit the property of randomness and, thus, can be utilized to generate random BSes. Compared with the schemes that solely rely on IPIs to generate BSes, this MFBSG algorithm uses five feature values from one heart beat cycle, and can be up to five times faster than the solely IPI-based methods. So, it achieves a design goal of low latency. According to our analysis, the complexity of the algorithm is comparable to that of fast Fourier transforms. These randomly generated ECG BSes can be used as security keys for encryption or authentication in a WBAN system.

  2. Electrocardiogram abnormalities and coronary calcification in postmenopausal women.

    PubMed

    Sabour, Siamak; Grobbee, Diederick; Rutten, Annemarieke; Prokop, Mathias; Bartelink, Marie-Louise; van der Schouw, Yvonne; Bots, Michiel

    2010-01-01

    An electrocardiogram (ECG) can provide information on subclinical myocardial damage. The presence, and more importantly, the quantity of coronary artery calcification (CAC), relates well with the overall severity of the atherosclerotic process. A strong relation has been demonstrated between coronary calcium burden and the incidence of myocardial infarction, a relation independent of age. The aim of this study was to assess the relation of left ventricular hypertrophy (LVH) and ECG abnormalities with CAC. The study population comprised 566 postmenopausal women selected from a population-based cohort study. Information on LVH and repolarization abnormalities (T-axis and QRS-T angle) was obtained using electrocardiography. Modular ECG Analysis System (MEANS) was used to assess ECG abnormalities. The women underwent a multi detector-row computed tomography (MDCT) scan (Philips Mx 8000 IDT 16) to assess CAC. The Agatston score was used to quantify CAC; scores greater than zero were considered as the presence of coronary calcium. Logistic regression was used to assess the relation of ECG abnormality with coronary calcification. LVH was found in 2.7% (n = 15) of the women. The prevalence of T-axis abnormality was 6% (n = 34), whereas 8.5% (n = 48) had a QRS-T angle abnormality. CAC was found in 62% of the women. Compared to women with a normal T-axis, women with borderline or abnormal T-axes were 3.8 fold more likely to have CAC (95% CI: 1.4-10.2). Similarly, compared to women with a normal QRS-T angle, in women with borderline or abnormal QRS-T angle, CAC was 2.0 fold more likely to be present (95% CI: 1.0-4.1). Among women with ECG abnormalities reflecting subclinical ischemia, CAC is commonly found and may in part explain the increased coronary heart disease risk associated with these ECG abnormalities.

  3. Systolic time interval data acquisition system. Specialized cardiovascular studies

    NASA Technical Reports Server (NTRS)

    Baker, J. T.

    1976-01-01

    The development of a data acquisition system for noninvasive measurement of systolic time intervals is described. R-R interval from the ECG determines instantaneous heart rate prior to the beat to be measured. Total electromechanical systole (Q-S2) is measured from the onset of the ECG Q-wave to the onset of the second heart sound (S2). Ejection time (ET or LVET) is measured from the onset of carotid upstroke to the incisure. Pre-ejection period (PEP) is computed by subtracting ET from Q-S2. PEP/ET ratio is computed directly.

  4. A mobile phone based telemonitoring concept for the simultaneous acquisition of biosignals physiological parameters.

    PubMed

    Kumpusch, Hannes; Hayn, Dieter; Kreiner, Karl; Falgenhauer, Markus; Mor, Jürgen; Schreier, Günter

    2010-01-01

    Congestive Heart Failure (CHF) is a common chronic heart disease with high socioeconomic impact. Conventional treatment of CHF is often ineffective and inefficient, since self-management is complex and patients are insufficiently involved in therapy management. With telemedical concepts, continuous monitoring of the health status can be ensured, and consequently therapy management can be adapted to the individual requirements of every individual patient. Therefore, a mobile phone based patient terminal for the concurrent acquisition of biosignals (e.g. ECG) and bioparameters (e.g. blood pressure) for patients with CHF has been developed and prototypically implemented. Usability and interoperability aspects were especially considered by using Bluetooth and Near Field Communication (NFC) technology for data acquisition and standardized data formats for transmission of the data to a central monitoring centre. Results indicated that even complicated measurements like the acquisition of ECG signals could be accomplished autonomously by the patients in an intuitive and easy-to-use way. Through the usage of IHE conform HL7 messages, self-measured data could easily be integrated into a higher-ranking eHealth infrastructure.

  5. Comparison of Digital 12-Lead ECG and Digital 12-Lead Holter ECG Recordings in Healthy Male Subjects: Results from a Randomized, Double-Blinded, Placebo-Controlled Clinical Trial.

    PubMed

    Wang, Duolao; Bakhai, Ameet; Arezina, Radivoj; Täubel, Jörg

    2016-11-01

    Electrocardiogram (ECG) variability is greatly affected by the ECG recording method. This study aims to compare Holter and standard ECG recording methods in terms of central locations and variations of ECG data. We used the ECG data from a double-blinded, placebo-controlled, randomized clinical trial and used a mixed model approach to assess the agreement between two methods in central locations and variations of eight ECG parameters (Heart Rate, PR, QRS, QT, RR, QTcB, QTcF, and QTcI intervals). A total of 34 heathy male subjects with mean age of 25.7 ± 4.78 years were randomized to receive either active drug or placebo. Digital 12-lead ECG and digital 12-lead Holter ECG recordings were performed to assess ECG variability. There are no significant differences in least square mean between the Holter and the standard method for all ECG parameters. The total variance is consistently higher for the Holter method than the standard method for all ECG parameters except for QRS. The intraclass correlation coefficient (ICC) values for the Holter method are consistently lower than those for the standard method for all ECG parameters except for QRS, in particular, the ICC for QTcF is reduced from 0.86 for the standard method to 0.67 for the Holter method. This study suggests that Holter ECGs recorded in a controlled environment are not significantly different but more variable than those from the standard method. © 2016 Wiley Periodicals, Inc.

  6. Some regularity on how to locate electrodes for higher fECG SNRs

    NASA Astrophysics Data System (ADS)

    Zhang, Jie-Min; Huang, Xiao-Lin; Guan, Qun; Liu, Tie-Bing; Li, Ping; Zhao, Ying; Liu, Hong-Xing

    2015-03-01

    The electrocardiogram (ECG) recorded from the abdominal surface of a pregnant woman is a composite of maternal ECG, fetal ECG (fECG) and other noises, while only the fECG component is always needed by us. With different locations of electrode pairs on the maternal abdominal surface to measure fECGs, the signal-to-noise ratios (SNRs) of the recorded abdominal ECGs are also correspondingly different. Some regularity on how to locate electrodes to obtain higher fECG SNRs is needed practically. In this paper, 343 groups of abdominal ECG records were acquired from 78 pregnant women with different electrode pairs locating, and an appropriate extended research database is formed. Then the regularity on fECG SNRs corresponding to different electrode pairs locating was studied. Based on statistical analysis, it is shown that the fECG SNRs are significantly higher in certain locations than others. Reasonable explanation is also provided to the statistical result using the theories of the fetal cardiac electrical axis and the signal phase delay. Project supported by the National Natural Science Foundation of China (Grant No. 61271079) and the Supporting Plan Project of Jiangsu Province, China (Grant No. BE2010720).

  7. Wireless Self-Acquistion of 12-Lead ECG via Android Smart Phone

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.

    2012-01-01

    Researchers at NASA s Johnson Space Center and at Orbital Research, Inc. (a NASA SBIR grant recipient) have recently developed a dry-electrode harness that allows for self-acquisition of resting 12-lead ECGs by minimally trained laypersons. When used in conjunction with commercial wireless (e.g., Bluetooth(TM) or 802.11-enabled) 12-lead ECG devices and custom smart phone-based software, the collected 12-lead ECG data can also immediately be forwarded from any geographic location within cellular range to the user s physician(s) of choice. The system can also be used to immediately forward to central receiving stations 12-lead ECG data collected during space flight or during activities in any remote terrestrial location supported by an internet or cellular phone infrastructure. The main novel aspects of the system are first, the dry-electrode 12-lead ECG harness itself, and second, an accompanying Android(TM) smart phone-based wireless 12-lead ECG capability. The ECG harness nominally employs dry electrodes manufactured by Orbital Research, Inc, recently cleared through the Food and Drug Administration (FDA). However, other dry electrodes that are not yet FDA cleared, for example those recently developed by Nanosonic, Inc as part of another NASA SBIR grant, can also be used. The various advantageous features of the harness include: 1) laypersons can be quickly instructed on its correct use, remotely if necessary; 2) all tangled "leadwire spaghetti" is eliminated, as is the common clinical problem of "leadwire reversal"; 3) all adhesives and disposables are also eliminated, the harness being fully reusable; if multiple individuals intend to use use the same harness, then standard antimicrobial wipes can be employed to sterilize the dry electrodes (and harness surface if needed) between users; 5) padded cushions at the lateral sides of the torso function to press the left arm (LA) and right arm (RA) dry electrodes mounted on the cushions against sideward or downward-rested arms of the subject; 6) sufficient distal placement of the arm electrodes achieves good electrode abutment to the arms without the need for adhesives, straps, bands, bracelets, or gloves; 7) padding over the sternum avoids "tenting" in the V1 through V3 (and, when present, the V3R) electrode positions; 8) easy-to-don, one-piece design with an adjustable, front-side single point of connection and an adjustable shoulder strap; and 9) Lund or "modified Lund" placement of the dry electrodes, the results of which more effectively reproduce results from "standard" 12-lead ECG placements than do results from Mason-Likar placements. The main limitation of the harness is that "one size does not fit all", meaning that an appropriately sized harness (small, medium, large, etc) must be chosen on the basis of an individual's size. To facilitate the use of the harness with inexpensive, commodity-grade cell phones and tablet devices, 12-lead ECG software is also being developed to accompany the harness for wireless use with Android. For this part of the project, NASA has teamed with TopCoder, Inc and the Harvard-affiliated NASA Tournament Lab in sponsoring java-based software programming contests through TopCoder. While ECG signals from the harness can already be wirelessly received and thoroughly processed (locally or remotely) by commercial-grade conventional (as well as advanced) 12-lead ECG software running on Microsoft Windows(TM), the Android-based software, once completed, will "cast a wider net" by allowing for a greater percentage of cell phone owners to participate in inexpensive, store-and-forward recordings of 12-lead ECGs worldwide, including for example Android cell phone users in many remote, third-world locations. At the time of writing, the Android 12-lead ECG software platform consists of a basic but expanding graphical user interface and accompanying software that: 1) wirelessly receives the 12-lead ECG data stream from a Bluetooth-based, FDA-cleared 12-leaCG device attached to the harness; 2) locally stores the same data in binary format to the SD card on the Android cell phone; and 3) makes the data stream in available in real time, for now to TopCoder's java programming contestants.

  8. Developments in the management of Chagas cardiomyopathy

    PubMed Central

    Tanowitz, Herbert B; Machado, Fabiana S; Spray, David C; Friedman, Joel M; Weiss, Oren S; Lora, Jose N; Nagajyothi, Jyothi; Moraes, Diego N; Garg, Nisha Jain; Nunes, Maria Carmo P; Ribeiro, Antonio Luiz P

    2016-01-01

    Over 100 years have elapsed since the discovery of Chagas disease and there is still much to learn regarding pathogenesis and treatment. Although there are antiparasitic drugs available, such as benznidazole and nifurtimox, they are not totally reliable and often toxic. A recently released negative clinical trial with benznidazole in patients with chronic Chagas cardiomyopathy further reinforces the concerns regarding its effectiveness. New drugs and new delivery systems, including those based on nanotechnology, are being sought. Although vaccine development is still in its infancy, the reality of a therapeutic vaccine remains a challenge. New ECG methods may help to recognize patients prone to developing malignant ventricular arrhythmias. The management of heart failure, stroke and arrhythmias also remains a challenge. Although animal experiments have suggested that stem cell based therapy may be therapeutic in the management of heart failure in Chagas cardiomyopathy, clinical trials have not been promising. PMID:26496376

  9. Developments in the management of Chagas cardiomyopathy.

    PubMed

    Tanowitz, Herbert B; Machado, Fabiana S; Spray, David C; Friedman, Joel M; Weiss, Oren S; Lora, Jose N; Nagajyothi, Jyothi; Moraes, Diego N; Garg, Nisha Jain; Nunes, Maria Carmo P; Ribeiro, Antonio Luiz P

    2015-12-01

    Over 100 years have elapsed since the discovery of Chagas disease and there is still much to learn regarding pathogenesis and treatment. Although there are antiparasitic drugs available, such as benznidazole and nifurtimox, they are not totally reliable and often toxic. A recently released negative clinical trial with benznidazole in patients with chronic Chagas cardiomyopathy further reinforces the concerns regarding its effectiveness. New drugs and new delivery systems, including those based on nanotechnology, are being sought. Although vaccine development is still in its infancy, the reality of a therapeutic vaccine remains a challenge. New ECG methods may help to recognize patients prone to developing malignant ventricular arrhythmias. The management of heart failure, stroke and arrhythmias also remains a challenge. Although animal experiments have suggested that stem cell based therapy may be therapeutic in the management of heart failure in Chagas cardiomyopathy, clinical trials have not been promising.

  10. Evolution and Evaluation of ECG Interpretation Systems-An Illustration of the Validation of Decision Support Systems

    PubMed Central

    van Bemmel, Jan H.; Kors, Jan A.; Willems, Jos L.; van Herpen, Gerard

    1990-01-01

    The last decade has shown a growing interest in medical decision making, strongly stimulated by the advent of artificial intelligence. This wave of interest is not the first one; it was preceded by other models and approaches to medical decision support. However, not all developments have resulted in equally successful decision support systems. Positive exceptions are the interpretation systems for ECGs that evolved all the way from very primitive attempts to well-accepted and highly-computerized clinical systems for which a major evaluation study (CSE, Common Standards for Quantitative Electrocardiography) is finalized in 1990. The evolution and the evaluation of the systems that took part in this study, is the subject of this paper.

  11. Characterization of dry biopotential electrodes.

    PubMed

    Xie, Li; Yang, Geng; Xu, Linlin; Seoane, Fernando; Chen, Qiang; Zheng, Lirong

    2013-01-01

    Driven by the increased interest in wearable long-term healthcare monitoring systems, varieties of dry electrodes are proposed based on different materials with different patterns and structures. Most of the studies reported in the literature focus on proposing new electrodes and comparing its performance with commercial electrodes. Few papers are about detailed comparison among different dry electrodes. In this paper, printed metal-plate electrodes, textile based electrodes, and spiked electrodes are for the first time evaluated and compared under the same experimental setup. The contact impedance and noise characterization are measured. The in-vivo electrocardiogram (ECG) measurement is applied to evaluate the overall performance of different electrodes. Textile electrodes and printed electrodes gain comparable high-quality ECG signals. The ECG signal obtained by spiked electrodes is noisier. However, a clear ECG envelope can be observed and the signal quality can be easily improved by backend signal processing. The features of each type of electrodes are analyzed and the suitable application scenario is addressed.

  12. Ultrasound measurement of the brachial artery flow-mediated dilation without ECG gating.

    PubMed

    Gemignani, Vincenzo; Bianchini, Elisabetta; Faita, Francesco; Giannarelli, Chiara; Plantinga, Yvonne; Ghiadoni, Lorenzo; Demi, Marcello

    2008-03-01

    The methods commonly used for noninvasive ultrasound assessment of endothelium-dependent flow-mediated dilation (FMD) require an electrocardiogram (ECG) signal to synchronize the measurements with the cardiac cycle. In this article, we present a method for assessing FMD that does not require ECG gating. The approach is based on temporal filtering of the diameter-time curve, which is obtained by means of a B-mode image processing system. The method was tested on 22 healthy volunteers without cardiovascular risk factors. The measurements obtained with the proposed approach were compared with those obtained with ECG gating and with both systolic and end-diastolic measurements. Results showed good agreement between the methods and a higher precision of the new method due to the fact that it is based on a larger number of measurements. Further advantages were also found both in terms of reliability of the measure and simplification of the instrumentation. (E-mail: gemi@ifc.cnr.it).

  13. Reliability and Reproducibility of Advanced ECG Parameters in Month-to-Month and Year-to-Year Recordings in Healthy Subjects

    NASA Technical Reports Server (NTRS)

    Starc, Vito; Abughazaleh, Ahmed S.; Schlegel, Todd T.

    2014-01-01

    Advanced resting ECG parameters such the spatial mean QRS-T angle and the QT variability index (QTVI) have important diagnostic and prognostic utility, but their reliability and reproducibility (R&R) are not well characterized. We hypothesized that the spatial QRS-T angle would have relatively higher R&R than parameters such as QTVI that are more responsive to transient changes in the autonomic nervous system. The R&R of several conventional and advanced ECG para-meters were studied via intraclass correlation coefficients (ICCs) and coefficients of variation (CVs) in: (1) 15 supine healthy subjects from month-to-month; (2) 27 supine healthy subjects from year-to-year; and (3) 25 subjects after transition from the supine to the seated posture. As hypothesized, for the spatial mean QRS-T angle and many conventional ECG parameters, ICCs we-re higher, and CVs lower than QTVI, suggesting that the former parameters are more reliable and reproducible.

  14. Development of electrocardiogram intervals during growth of FVB/N neonate mice

    PubMed Central

    2010-01-01

    Background Electrocardiography remains the best diagnostic tool and therapeutic biomarker for a spectrum of pediatric diseases involving cardiac or autonomic nervous system defects. As genetic links to these disorders are established and transgenic mouse models produced in efforts to understand and treat them, there is a surprising lack of information on electrocardiograms (ECGs) and ECG abnormalities in neonate mice. This is likely due to the trauma and anaesthesia required of many legacy approaches to ECG recording in mice, exacerbated by the fragility of many mutant neonates. Here, we use a non-invasive system to characterize development of the heart rate and electrocardiogram throughout the growth of conscious neonate FVB/N mice. Results We examine ECG waveforms as early as two days after birth. At this point males and females demonstrate comparable heart rates that are 50% lower than adult mice. Neonatal mice exhibit very low heart rate variability. Within 12 days of birth PR, QRS and QTc interval durations are near adult values while heart rate continues to increase until weaning. Upon weaning FVB/N females quickly develop slower heart rates than males, though PR intervals are comparable between sexes until a later age. This suggests separate developmental events may contribute to these gender differences in electrocardiography. Conclusions We provide insight with a new level of detail to the natural course of heart rate establishment in neonate mice. ECG can now be conveniently and repeatedly used in neonatal mice. This should serve to be of broad utility, facilitating further investigations into development of a diverse group of diseases and therapeutics in preclinical mouse studies. PMID:20735846

  15. ECG Sensor Card with Evolving RBP Algorithms for Human Verification.

    PubMed

    Tseng, Kuo-Kun; Huang, Huang-Nan; Zeng, Fufu; Tu, Shu-Yi

    2015-08-21

    It is known that cardiac and respiratory rhythms in electrocardiograms (ECGs) are highly nonlinear and non-stationary. As a result, most traditional time-domain algorithms are inadequate for characterizing the complex dynamics of the ECG. This paper proposes a new ECG sensor card and a statistical-based ECG algorithm, with the aid of a reduced binary pattern (RBP), with the aim of achieving faster ECG human identity recognition with high accuracy. The proposed algorithm has one advantage that previous ECG algorithms lack-the waveform complex information and de-noising preprocessing can be bypassed; therefore, it is more suitable for non-stationary ECG signals. Experimental results tested on two public ECG databases (MIT-BIH) from MIT University confirm that the proposed scheme is feasible with excellent accuracy, low complexity, and speedy processing. To be more specific, the advanced RBP algorithm achieves high accuracy in human identity recognition and is executed at least nine times faster than previous algorithms. Moreover, based on the test results from a long-term ECG database, the evolving RBP algorithm also demonstrates superior capability in handling long-term and non-stationary ECG signals.

  16. Bivariate empirical mode decomposition for ECG-based biometric identification with emotional data.

    PubMed

    Ferdinando, Hany; Seppanen, Tapio; Alasaarela, Esko

    2017-07-01

    Emotions modulate ECG signals such that they might affect ECG-based biometric identification in real life application. It motivated in finding good feature extraction methods where the emotional state of the subjects has minimum impacts. This paper evaluates feature extraction based on bivariate empirical mode decomposition (BEMD) for biometric identification when emotion is considered. Using the ECG signal from the Mahnob-HCI database for affect recognition, the features were statistical distributions of dominant frequency after applying BEMD analysis to ECG signals. The achieved accuracy was 99.5% with high consistency using kNN classifier in 10-fold cross validation to identify 26 subjects when the emotional states of the subjects were ignored. When the emotional states of the subject were considered, the proposed method also delivered high accuracy, around 99.4%. We concluded that the proposed method offers emotion-independent features for ECG-based biometric identification. The proposed method needs more evaluation related to testing with other classifier and variation in ECG signals, e.g. normal ECG vs. ECG with arrhythmias, ECG from various ages, and ECG from other affective databases.

  17. Wearable technology and ECG processing for fall risk assessment, prevention and detection.

    PubMed

    Melillo, Paolo; Castaldo, Rossana; Sannino, Giovanna; Orrico, Ada; de Pietro, Giuseppe; Pecchia, Leandro

    2015-01-01

    Falls represent one of the most common causes of injury-related morbidity and mortality in later life. Subjects with cardiovascular disorders (e.g., related to autonomic dysfunctions and postural hypotension) are at higher risk of falling. Autonomic dysfunctions increasing the risk of falling in the short and mid-term could be assessed by Heart Rate Variability (HRV) extracted by electrocardiograph (ECG). We developed three trials for assessing the usefulness of ECG monitoring using wearable devices for: risk assessment of falling in the next few weeks; prevention of imminent falls due to standing hypotension; and fall detection. Statistical and data-mining methods are adopted to develop classification and regression models, validated with the cross-validation approach. The first classifier based on HRV features enabled to identify future fallers among hypertensive patients with an accuracy of 72% (sensitivity: 51.1%, specificity: 80.2%). The regression model to predict falls due to orthostatic dropdown from HRV recorded before standing achieved an overall accuracy of 80% (sensitivity: 92%, specificity: 90%). Finally, the classifier to detect simulated falls using ECG achieved an accuracy of 77.3% (sensitivity: 81.8%, specificity: 72.7%). The evidence from these three studies showed that ECG monitoring and processing could achieve satisfactory performances compared to other system for risk assessment, fall prevention and detection. This is interesting as differently from other technologies actually employed to prevent falls, ECG is recommended for many other pathologies of later life and is more accepted by senior citizens.

  18. Competency in ECG Interpretation Among Medical Students

    PubMed Central

    Kopeć, Grzegorz; Magoń, Wojciech; Hołda, Mateusz; Podolec, Piotr

    2015-01-01

    Background Electrocardiogram (ECG) is commonly used in diagnosis of heart diseases, including many life-threatening disorders. We aimed to assess skills in ECG interpretation among Polish medical students and to analyze the determinants of these skills. Material/Methods Undergraduates from all Polish medical schools were asked to complete a web-based survey containing 18 ECG strips. Questions concerned primary ECG parameters (rate, rhythm, and axis), emergencies, and common ECG abnormalities. Analysis was restricted to students in their clinical years (4th–6th), and students in their preclinical years (1st–3rd) were used as controls. Results We enrolled 536 medical students (females: n=299; 55.8%), aged 19 to 31 (23±1.6) years from all Polish medical schools. Most (72%) were in their clinical years. The overall rate of good response was better in students in years 4th–5th than those in years 1st–3rd (66% vs. 56%; p<0.0001). Competency in ECG interpretation was higher in students who reported ECG self-learning (69% vs. 62%; p<0.0001) but no difference was found between students who attended or did not attend regular ECG classes (66% vs. 66%; p=0.99). On multivariable analysis (p<0.0001), being in clinical years (OR: 2.45 [1.35–4.46] and self-learning (OR: 2.44 [1.46–4.08]) determined competency in ECG interpretation. Conclusions Polish medical students in their clinical years have a good level of competency in interpreting the primary ECG parameters, but their ability to recognize ECG signs of emergencies and common heart abnormalities is low. ECG interpretation skills are determined by self-education but not by attendance at regular ECG classes. Our results indicate qualitative and quantitative deficiencies in teaching ECG interpretation at medical schools. PMID:26541993

  19. Acute hypoxia during organogenesis affects cardiac autonomic balance in pregnant rats.

    PubMed

    Maslova, M V; Graf, A V; Maklakova, A S; Krushinskaya, Ya V; Sokolova, N A; Koshelev, V B

    2005-02-01

    Changes in ECG parameters were studied in pregnant rats exposed to acute hypobaric hypoxia during the period of organogenesis (gestation days 9 to 10). Rats with low, medium, and high tolerance to hypoxia exhibited pronounced autonomic nervous system imbalance, which become apparent as a loss of correlation between various parameters of ECG signals recorded at rest and during exposure to some stress factors existing under normal conditions.

  20. A QRS Detection and R Point Recognition Method for Wearable Single-Lead ECG Devices.

    PubMed

    Chen, Chieh-Li; Chuang, Chun-Te

    2017-08-26

    In the new-generation wearable Electrocardiogram (ECG) system, signal processing with low power consumption is required to transmit data when detecting dangerous rhythms and to record signals when detecting abnormal rhythms. The QRS complex is a combination of three of the graphic deflection seen on a typical ECG. This study proposes a real-time QRS detection and R point recognition method with low computational complexity while maintaining a high accuracy. The enhancement of QRS segments and restraining of P and T waves are carried out by the proposed ECG signal transformation, which also leads to the elimination of baseline wandering. In this study, the QRS fiducial point is determined based on the detected crests and troughs of the transformed signal. Subsequently, the R point can be recognized based on four QRS waveform templates and preliminary heart rhythm classification can be also achieved at the same time. The performance of the proposed approach is demonstrated using the benchmark of the MIT-BIH Arrhythmia Database, where the QRS detected sensitivity (Se) and positive prediction (+P) are 99.82% and 99.81%, respectively. The result reveals the approach's advantage of low computational complexity, as well as the feasibility of the real-time application on a mobile phone and an embedded system.

  1. A markup language for electrocardiogram data acquisition and analysis (ecgML)

    PubMed Central

    Wang, Haiying; Azuaje, Francisco; Jung, Benjamin; Black, Norman

    2003-01-01

    Background The storage and distribution of electrocardiogram data is based on different formats. There is a need to promote the development of standards for their exchange and analysis. Such models should be platform-/ system- and application-independent, flexible and open to every member of the scientific community. Methods A minimum set of information for the representation and storage of electrocardiogram signals has been synthesised from existing recommendations. This specification is encoded into an XML-vocabulary. The model may aid in a flexible exchange and analysis of electrocardiogram information. Results Based on advantages of XML technologies, ecgML has the ability to present a system-, application- and format-independent solution for representation and exchange of electrocardiogram data. The distinction between the proposal developed by the U.S Food and Drug Administration and ecgML model is given. A series of tools, which aim to facilitate ecgML-based applications, are presented. Conclusions The models proposed here can facilitate the generation of a data format, which opens ways for better and clearer interpretation by both humans and machines. Its structured and transparent organisation will allow researchers to expand and test its capabilities in different application domains. The specification and programs for this protocol are publicly available. PMID:12735790

  2. Block sparsity-based joint compressed sensing recovery of multi-channel ECG signals.

    PubMed

    Singh, Anurag; Dandapat, Samarendra

    2017-04-01

    In recent years, compressed sensing (CS) has emerged as an effective alternative to conventional wavelet based data compression techniques. This is due to its simple and energy-efficient data reduction procedure, which makes it suitable for resource-constrained wireless body area network (WBAN)-enabled electrocardiogram (ECG) telemonitoring applications. Both spatial and temporal correlations exist simultaneously in multi-channel ECG (MECG) signals. Exploitation of both types of correlations is very important in CS-based ECG telemonitoring systems for better performance. However, most of the existing CS-based works exploit either of the correlations, which results in a suboptimal performance. In this work, within a CS framework, the authors propose to exploit both types of correlations simultaneously using a sparse Bayesian learning-based approach. A spatiotemporal sparse model is employed for joint compression/reconstruction of MECG signals. Discrete wavelets transform domain block sparsity of MECG signals is exploited for simultaneous reconstruction of all the channels. Performance evaluations using Physikalisch-Technische Bundesanstalt MECG diagnostic database show a significant gain in the diagnostic reconstruction quality of the MECG signals compared with the state-of-the art techniques at reduced number of measurements. Low measurement requirement may lead to significant savings in the energy-cost of the existing CS-based WBAN systems.

  3. Microcontroller-based underwater acoustic ECG telemetry system.

    PubMed

    Istepanian, R S; Woodward, B

    1997-06-01

    This paper presents a microcontroller-based underwater acoustic telemetry system for digital transmission of the electrocardiogram (ECG). The system is designed for the real time, through-water transmission of data representing any parameter, and it was used initially for transmitting in multiplexed format the heart rate, breathing rate and depth of a diver using self-contained underwater breathing apparatus (SCUBA). Here, it is used to monitor cardiovascular reflexes during diving and swimming. The programmable capability of the system provides an effective solution to the problem of transmitting data in the presence of multipath interference. An important feature of the paper is a comparative performance analysis of two encoding methods, Pulse Code Modulation (PCM) and Pulse Position Modulation (PPM).

  4. A portable system for acquiring and removing motion artefact from ECG signals

    NASA Astrophysics Data System (ADS)

    Griffiths, A.; Das, A.; Fernandes, B.; Gaydecki, P.

    2007-07-01

    A novel electrocardiograph (ECG) signal acquisition and display system is under development. It is designed for patients ranging from the elderly to athletes. The signals are obtained from electrodes integrated into a vest, amplified, digitally processed and transmitted via Bluetooth to a PC with a Labview ® interface. Digital signal processing is performed to remove movement artefact and electromyographic (EMG) noise, which severely distorts signal morphology and complicates clinical diagnosis. Independent component analysis (ICA) is also used to improve the signal quality. The complete system will integrate the electronics into a single module which will be embedded in the vest.

  5. The availability of prior ECGs improves paramedic accuracy in recognizing ST-segment elevation myocardial infarction.

    PubMed

    O'Donnell, Daniel; Mancera, Mike; Savory, Eric; Christopher, Shawn; Schaffer, Jason; Roumpf, Steve

    2015-01-01

    Early and accurate identification of ST-elevation myocardial infarction (STEMI) by prehospital providers has been shown to significantly improve door to balloon times and improve patient outcomes. Previous studies have shown that paramedic accuracy in reading 12 lead ECGs can range from 86% to 94%. However, recent studies have demonstrated that accuracy diminishes for the more uncommon STEMI presentations (e.g. lateral). Unlike hospital physicians, paramedics rarely have the ability to review previous ECGs for comparison. Whether or not a prior ECG can improve paramedic accuracy is not known. The availability of prior ECGs improves paramedic accuracy in ECG interpretation. 130 paramedics were given a single clinical scenario. Then they were randomly assigned 12 computerized prehospital ECGs, 6 with and 6 without an accompanying prior ECG. All ECGs were obtained from a local STEMI registry. For each ECG paramedics were asked to determine whether or not there was a STEMI and to rate their confidence in their interpretation. To determine if the old ECGs improved accuracy we used a mixed effects logistic regression model to calculate p-values between the control and intervention. The addition of a previous ECG improved the accuracy of identifying STEMIs from 75.5% to 80.5% (p=0.015). A previous ECG also increased paramedic confidence in their interpretation (p=0.011). The availability of previous ECGs improves paramedic accuracy and enhances their confidence in interpreting STEMIs. Further studies are needed to evaluate this impact in a clinical setting. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Predictors of electrocardiographic abnormalities in type 1 Diabetes: the Wisconsin Epidemiologic Study of Diabetic Retinopathy.

    PubMed

    O'Neal, Wesley T; Lee, Kristine E; Soliman, Elsayed Z; Klein, Ronald; Klein, Barbara E K

    2017-03-01

    To determine the incidence and determinants of developing abnormalities on the 12-lead electrocardiogram (ECG) in persons with type 1 diabetes. We evaluated the distribution of ECG abnormalities and risk factors for developing new abnormalities in 266 (mean age = 44 years ± 9.0; 50 % female) people with type 1 diabetes from the Wisconsin Epidemiologic Study of Diabetic Retinopathy. This analysis included participants with complete ECG data from study visit 5 (2000-2001) and follow-up ECGs from study visit 7 (2012-2014). ECG abnormalities were classified as major and minor according to Minnesota Code Classification. At baseline, 94 (35 %) participants had at least one ECG abnormality, including 13 major ECG abnormalities. At follow-up, 117 (44 %) participants developed at least one new ECG abnormality, including 35 new major ECG abnormalities. In a multivariable logistic regression model, older age (per 5-year increase: OR = 1.31, 95 % CI = 1.08, 1.60) was associated with the development of at least one new ECG abnormality, while serum HDL cholesterol (per 10-unit increase: OR = 0.98, 95 % CI = 0.96, 1.00) was protective against developing new ECG abnormalities. The development of new ECG abnormalities is common in type 1 diabetes. Older age and HDL cholesterol are independent risk factors for developing new ECG abnormalities. Further research is needed to determine whether routine ECG screening is indicated in people with type 1 diabetes to identify those with underlying subclinical coronary heart disease.

  7. Cohort Study of ECG Left Ventricular Hypertrophy Trajectories: Ethnic Disparities, Associations With Cardiovascular Outcomes, and Clinical Utility.

    PubMed

    Iribarren, Carlos; Round, Alfred D; Lu, Meng; Okin, Peter M; McNulty, Edward J

    2017-10-05

    ECG left ventricular hypertrophy (LVH) is a well-known predictor of cardiovascular disease. However, no prior study has characterized patterns of presence/absence of ECG LVH ("ECG LVH trajectories") across the adult lifespan in both sexes and across ethnicities. We examined: (1) correlates of ECG LVH trajectories; (2) the association of ECG LVH trajectories with incident coronary heart disease, transient ischemic attack, ischemic stroke, hemorrhagic stroke, and heart failure; and (3) reclassification of cardiovascular disease risk using ECG LVH trajectories. We performed a cohort study among 75 412 men and 107 954 women in the Northern California Kaiser Permanente Medical Care Program who had available longitudinal exposures of ECG LVH and covariates, followed for a median of 4.8 (range <1-9.3) years. ECG LVH was measured by Cornell voltage-duration product. Adverse trajectories of ECG LVH (persistent, new development, or variable pattern) were more common among blacks and Native American men and were independently related to incident cardiovascular disease with hazard ratios ranging from 1.2 for ECG LVH variable pattern and transient ischemic attack in women to 2.8 for persistent ECG LVH and heart failure in men. ECG LVH trajectories reclassified 4% and 7% of men and women with intermediate coronary heart disease risk, respectively. ECG LVH trajectories were significant indicators of coronary heart disease, stroke, and heart failure risk, independently of level and change in cardiovascular disease risk factors, and may have clinical utility. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  8. Mobile Cardiac Health-care Monitoring and Notification with Real Time Tachycardia and Bradycardia Arrhythmia Detection.

    PubMed

    Golzar, Mina; Fotouhi-Ghazvini, Faranak; Rabbani, Hossein; Zakeri, Fahimeh Sadat

    2017-01-01

    The increasing trend of heart disease has turned the attention of researchers toward the use of portable connected technologies. The necessity of continuous special care for cardiovascular patients is an inevitable fact. In this research, a new wireless electrocardiographic (ECG) signal-monitoring system based on smartphone is presented. This system has two main sections. The first section consists of a sensor which receives ECG signals via an amplifier, then filters and digitizes the signal, and prepares it to be transmitted. The signals are stored, processed, and then displayed in a mobile application. The application alarms in dangerous situations and sends the location of the cardiac patient to family or health-care staff. The results obtained from the analysis of the electrocardiogram signals on 20 different people have been compared with the traditional ECG in hospital by a cardiologist. The signal is instantly transmitted by 200 sample per second to mobile phone. The raw data are processed, the anomaly is detected, and the signal is drawn on the interface in about 70 s. Therefore, the delay is not noticeable by the patient. With respect to rate of data transmission to hospital, different internet connections such as 2G, 3G, 4G, WiFi, WiMax, or Long-Term Evolution (LTE) could be used. Data transmission ranges from 9.6 kbps to 20 Mbps. Therefore, the physician could receive data with no delay. A performance accuracy of 91.62% is obtained from the wireless ECG system. It conforms to the hospital's diagnostic standard system while providing a portable monitoring anywhere at anytime.

  9. Public access defibrillation: suppression of 16.7 Hz interference generated by the power supply of the railway systems.

    PubMed

    Christov, Ivaylo I; Iliev, Georgi L

    2005-03-15

    A specific problem using the public access defibrillators (PADs) arises at the railway stations. Some countries as Germany, Austria, Switzerland, Norway and Sweden are using AC railroad net power-supply system with rated 16.7 Hz frequency modulated from 15.69 Hz to 17.36 Hz. The power supply frequency contaminates the electrocardiogram (ECG). It is difficult to be suppressed or eliminated due to the fact that it considerably overlaps the frequency spectra of the ECG. The interference impedes the automated decision of the PADs whether a patient should be (or should not be) shocked. The aim of this study is the suppression of the 16.7 Hz interference generated by the power supply of the railway systems. Software solution using adaptive filtering method was proposed for 16.7 Hz interference suppression. The optimal performance of the filter is achieved, embedding a reference channel in the PADs to record the interference. The method was tested with ECGs from AHA database. The method was tested with patients of normal sinus rhythms, symptoms of tachycardia and ventricular fibrillation. Simulated interference with frequency modulation from 15.69 Hz to 17.36 Hz changing at a rate of 2% per second was added to the ECGs, and then processed by the suggested adaptive filtering. The method totally suppresses the noise with no visible distortions of the original signals. The proposed adaptive filter for noise suppression generated by the power supply of the railway systems has a simple structure requiring a low level of computational resources, but a good reference signal as well.

  10. Evaluation of agreement between temporal series obtained from electrocardiogram and pulse wave.

    NASA Astrophysics Data System (ADS)

    Leikan, GM; Rossi, E.; Sanz, MCuadra; Delisle Rodríguez, D.; Mántaras, MC; Nicolet, J.; Zapata, D.; Lapyckyj, I.; Siri, L. Nicola; Perrone, MS

    2016-04-01

    Heart rate variability allows to study the cardiovascular autonomic nervous system modulation. Usually, this signal is obtained from the electrocardiogram (ECG). A simpler method for recording the pulse wave (PW) is by means of finger photoplethysmography (PPG), which also provides information about the duration of the cardiac cycle. In this study, the correlation and agreement between the time series of the intervals between heartbeats obtained from the ECG with those obtained from the PPG, were studied. Signals analyzed were obtained from young, healthy and resting subjects. For statistical analysis, the Pearson correlation coefficient and the Bland and Altman limits of agreement were used. Results show that the time series constructed from the PW would not replace the ones obtained from ECG.

  11. A wearable wireless ECG monitoring system with dynamic transmission power control for long-term homecare.

    PubMed

    Wang, Yishan; Doleschel, Sammy; Wunderlich, Ralf; Heinen, Stefan

    2015-03-01

    This paper presents a wearable wireless ECG monitoring system based on novel 3-Lead electrode placements for long-term homecare. The experiment for novel 3-Lead electrode placements is carried out, and the results show that the distance between limb electrodes can be significantly reduced. Based on the new electrode position, a small size sensor node, which is powered by a rechargeable battery, is designed to detect, amplify, filter and transmit the ECG signals. The coordinator receives the data and sends it to PC. Finally the signals are displayed on the GUI. In order to control the power consumption of sensor node, a dynamic power adjustment method is applied to automatically adjust the transmission power of the sensor node according to the received signal strength indicator (RSSI), which is related to the distance and obstacle between sensor node and coordinator. The system is evaluated when the user, who wears the sensor, is walking and running. A promising performance is achieved even under body motion. The power consumption can be significantly reduced with this dynamic power adjustment method.

  12. The non-contact heart rate measurement system for monitoring HRV.

    PubMed

    Huang, Ji-Jer; Yu, Sheng-I; Syu, Hao-Yi; See, Aaron Raymond

    2013-01-01

    A noncontact ECG monitoring and analysis system was developed using capacitive-coupled device integrated to a home sofa. Electrodes were placed on the backrest of a sofa separated from the body with only the chair covering and the user's clothing. The study also incorporates measurements using different fabric materials, and a pure cotton material was chosen to cover the chair's backrest. The material was chosen to improve the signal to noise ratio. The system is initially implemented on a home sofa and is able to measure non-contact ECG through thin cotton clothing and perform heart rate analysis to calculate the heart rate variability (HRV) parameters. It was also tested under different conditions and results from reading and sleeping exhibited a stable ECG. Subsequently, results from our calculated HRV were found to be identical to those of a commercially available HRV analyzer. However, HRV parameters are easily affected by motion artifacts generated during drinking or eating with the latter producing a more severe disturbance. Lastly, parameters measured are saved on a cloud database, providing users with a long-term monitoring and recording for physiological information.

  13. Low-power wireless ECG acquisition and classification system for body sensor networks.

    PubMed

    Lee, Shuenn-Yuh; Hong, Jia-Hua; Hsieh, Cheng-Han; Liang, Ming-Chun; Chang Chien, Shih-Yu; Lin, Kuang-Hao

    2015-01-01

    A low-power biosignal acquisition and classification system for body sensor networks is proposed. The proposed system consists of three main parts: 1) a high-pass sigma delta modulator-based biosignal processor (BSP) for signal acquisition and digitization, 2) a low-power, super-regenerative on-off keying transceiver for short-range wireless transmission, and 3) a digital signal processor (DSP) for electrocardiogram (ECG) classification. The BSP and transmitter circuits, which are the body-end circuits, can be operated for over 80 days using two 605 mAH zinc-air batteries as the power supply; the power consumption is 586.5 μW. As for the radio frequency receiver and DSP, which are the receiving-end circuits that can be integrated in smartphones or personal computers, power consumption is less than 1 mW. With a wavelet transform-based digital signal processing circuit and a diagnosis control by cardiologists, the accuracy of beat detection and ECG classification are close to 99.44% and 97.25%, respectively. All chips are fabricated in TSMC 0.18-μm standard CMOS process.

  14. [Continuous registration of micropotentials of the human heart. Initial experiences with a new high resolution ECG amplifier system].

    PubMed

    Hombach, V; Kebbel, U; Höpp, H W; Winter, U J; Braun, V; Deutsch, H; Hirche, H; Hilger, H H

    1982-12-24

    A new ECG-amplifier system for recording cardiac microvolt potentials from the body surface is described. The improvement in signal-to-noise ratio was achieved by using specially designed suction electrodes, which were isolated from each other; by applying parallel signal averaging from four electrode pairs via four low-noise amplifiers; and by conducting the registration in Faraday cage. in 14 normal subjects, 12 patients with coronary heart disease and one patient with surgically corrected ventricular septal defect and pulmonary stenosis, pre-P-potentials (possible sinus node activity), His bundle potentials and ventricular late potentials were recorded with differing degrees of success. Variations of the time intervals to the preceding QRS complex were observed within the S-T segment in six of nine patients with demonstrable ventricular late ventricular late potentials. The advantage of such continuously recording ECG system lies in the highly accurate registration of cardiac micropotentials, particularly with ventricular late potentials that are changing in time, whereas the signal-averaging technique does not provide such possibilities.

  15. A systematic review of prenatal screening for congenital heart disease by fetal electrocardiography.

    PubMed

    Verdurmen, Kim M J; Eijsvoogel, Noortje B; Lempersz, Carlijn; Vullings, Rik; Schroer, Christian; van Laar, Judith O E H; Oei, S Guid

    2016-11-01

    Congenital heart disease (CHD) is the most common severe congenital anomaly worldwide. Diagnosis early in pregnancy is important, but the detection rate by two-dimensional ultrasonography is only 65%-81%. To evaluate existing data on CHD and noninvasive abdominal fetal electrocardiography (ECG). A systematic review was performed through a search of the Cochrane Library, PubMed, and Embase for studies published up to April 2016 using the terms "congenital heart disease," "fetal electrocardiogram," and other similar keywords. Primary articles that described changes in fetal ECG among fetuses with CHD published in English were included. Outcomes of interest were changes in fetal ECG parameters observed for fetuses with congenital heart disease. Findings were reported descriptively. Only five studies described changes observed in the fetal electrocardiogram for fetuses with CHD, including heart rate, heart rate variability, and PR, QRS, and QT intervals. Fetal ECG reflects the intimate relationship between the cardiac nerve conduction system and the structural morphology of the heart. It seems particularly helpful in detecting the electrophysiological effects of cardiac anatomic defects (e.g. hypotrophy, hypertrophy, and conduction interruption). Fetal ECG might be a promising clinical tool to complement ultrasonography in the screening program for CHD. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  16. Automatic detection of respiration rate from ambulatory single-lead ECG.

    PubMed

    Boyle, Justin; Bidargaddi, Niranjan; Sarela, Antti; Karunanithi, Mohan

    2009-11-01

    Ambulatory electrocardiography is increasingly being used in clinical practice to detect abnormal electrical behavior of the heart during ordinary daily activities. The utility of this monitoring can be improved by deriving respiration, which previously has been based on overnight apnea studies where patients are stationary, or the use of multilead ECG systems for stress testing. We compared six respiratory measures derived from a single-lead portable ECG monitor with simultaneously measured respiration air flow obtained from an ambulatory nasal cannula respiratory monitor. Ten controlled 1-h recordings were performed covering activities of daily living (lying, sitting, standing, walking, jogging, running, and stair climbing) and six overnight studies. The best method was an average of a 0.2-0.8 Hz bandpass filter and RR technique based on lengthening and shortening of the RR interval. Mean error rates with the reference gold standard were +/-4 breaths per minute (bpm) (all activities), +/-2 bpm (lying and sitting), and +/-1 breath per minute (overnight studies). Statistically similar results were obtained using heart rate information alone (RR technique) compared to the best technique derived from the full ECG waveform that simplifies data collection procedures. The study shows that respiration can be derived under dynamic activities from a single-lead ECG without significant differences from traditional methods.

  17. Cancelable ECG biometrics using GLRT and performance improvement using guided filter with irreversible guide signal.

    PubMed

    Kim, Hanvit; Minh Phuong Nguyen; Se Young Chun

    2017-07-01

    Biometrics such as ECG provides a convenient and powerful security tool to verify or identify an individual. However, one important drawback of biometrics is that it is irrevocable. In other words, biometrics cannot be re-used practically once it is compromised. Cancelable biometrics has been investigated to overcome this drawback. In this paper, we propose a cancelable ECG biometrics by deriving a generalized likelihood ratio test (GLRT) detector from a composite hypothesis testing in randomly projected domain. Since it is common to observe performance degradation for cancelable biometrics, we also propose a guided filtering (GF) with irreversible guide signal that is a non-invertibly transformed signal of ECG authentication template. We evaluated our proposed method using ECG-ID database with 89 subjects. Conventional Euclidean detector with original ECG template yielded 93.9% PD1 (detection probability at 1% FAR) while Euclidean detector with 10% compressed ECG (1/10 of the original data size) yielded 90.8% PD1. Our proposed GLRT detector with 10% compressed ECG yielded 91.4%, which is better than Euclidean with the same compressed ECG. GF with our proposed irreversible ECG template further improved the performance of our GLRT with 10% compressed ECG up to 94.3%, which is higher than Euclidean detector with original ECG. Lastly, we showed that our proposed cancelable ECG biometrics practically met cancelable biometrics criteria such as efficiency, re-usability, diversity and non-invertibility.

  18. A low-power bio-potential acquisition system with flexible PDMS dry electrodes for portable ubiquitous healthcare applications.

    PubMed

    Chen, Chih-Yuan; Chang, Chia-Lin; Chang, Chih-Wei; Lai, Shin-Chi; Chien, Tsung-Fu; Huang, Hong-Yi; Chiou, Jin-Chern; Luo, Ching-Hsing

    2013-03-04

    This work describes a bio-potential acquisition system for portable ubiquitous healthcare applications using flexible polydimethylsiloxane dry electrodes (FPDEs) and a low-power recording circuit. This novel FPDE used Au as the skin contact layer, which was made using a CO2 laser and replica method technology. The FPDE was revised from a commercial bio-potential electrode with a conductive snap using dry electrodes rather than wet electrodes that proposed reliable and robust attachment for the purpose of measurement, and attaching velcro made it wearable on the forearm for bio-potential applications. Furthermore, this study proposes a recording device to store bio-potential signal data and provides portability and low-power consumption for the proposed acquisition system. To acquire differential bio-potentials, such as electrocardiogram (ECG) signals, the proposed recording device includes a low-power front-end acquisition chip fabricated using a complementary metal-oxide-semiconductor (CMOS) process, a commercial microcontroller (MSP430F149), and a secure digital (SD) card for portable healthcare applications. The proposed system can obtain ECG signals efficiently and are comfortable to the skin. The power consumption of the system is about 85 mW for continuous working over a 3 day period with two AA batteries. It can also be used as a compact Holter ECG system.

  19. An innovative nonintrusive driver assistance system for vital signal monitoring.

    PubMed

    Sun, Ye; Yu, Xiong Bill

    2014-11-01

    This paper describes an in-vehicle nonintrusive biopotential measurement system for driver health monitoring and fatigue detection. Previous research has found that the physiological signals including eye features, electrocardiography (ECG), electroencephalography (EEG) and their secondary parameters such as heart rate and HR variability are good indicators of health state as well as driver fatigue. A conventional biopotential measurement system requires the electrodes to be in contact with human body. This not only interferes with the driver operation, but also is not feasible for long-term monitoring purpose. The driver assistance system in this paper can remotely detect the biopotential signals with no physical contact with human skin. With delicate sensor and electronic design, ECG, EEG, and eye blinking can be measured. Experiments were conducted on a high fidelity driving simulator to validate the system performance. The system was found to be able to detect the ECG/EEG signals through cloth or hair with no contact with skin. Eye blinking activities can also be detected at a distance of 10 cm. Digital signal processing algorithms were developed to decimate the signal noise and extract the physiological features. The extracted features from the vital signals were further analyzed to assess the potential criterion for alertness and drowsiness determination.

  20. Mental Stress: Neurophysiology and Its Regulation by Sudarshan Kriya Yoga.

    PubMed

    Chandra, Sushil; Jaiswal, Amit Kumar; Singh, Ram; Jha, Devendra; Mittal, Alok Prakash

    2017-01-01

    The present study focuses on analyzing the effects of Sudarshan Kriya yoga (SKY) on EEG as well as ECG signals for stress regulation. To envision the regulation of stress Determination Test (DT) has been used. We have chosen a control group for contriving a cogent comparison that could be corroborated using statistical tests. A total of 20 subjects were taken in the study, of which 10 were allotted to a control group. Electroencephalograph was taken during a DT task, before and after SKY the sky session with 30 days of SKY session given to the experimental group. No SKY was given to the control group. We quantified mental stress using EEG, ECG and DT synergistically and used SKY to regulate it. We observed that alpha band power decreases in the frontal lobe of the brain with increasing mental stress while frontal brain asymmetry decreases with increasing stress tolerance. These EEG, ECG and DT shows a significant decrement in mental stress and improvement in cognitive performance after SKY, indicating SKY as a good alternative of medication for stress management.

  1. A new feature detection mechanism and its application in secured ECG transmission with noise masking.

    PubMed

    Sufi, Fahim; Khalil, Ibrahim

    2009-04-01

    With cardiovascular disease as the number one killer of modern era, Electrocardiogram (ECG) is collected, stored and transmitted in greater frequency than ever before. However, in reality, ECG is rarely transmitted and stored in a secured manner. Recent research shows that eavesdropper can reveal the identity and cardiovascular condition from an intercepted ECG. Therefore, ECG data must be anonymized before transmission over the network and also stored as such in medical repositories. To achieve this, first of all, this paper presents a new ECG feature detection mechanism, which was compared against existing cross correlation (CC) based template matching algorithms. Two types of CC methods were used for comparison. Compared to the CC based approaches, which had 40% and 53% misclassification rates, the proposed detection algorithm did not perform any single misclassification. Secondly, a new ECG obfuscation method was designed and implemented on 15 subjects using added noises corresponding to each of the ECG features. This obfuscated ECG can be freely distributed over the internet without the necessity of encryption, since the original features needed to identify personal information of the patient remain concealed. Only authorized personnel possessing a secret key will be able to reconstruct the original ECG from the obfuscated ECG. Distribution of the would appear as regular ECG without encryption. Therefore, traditional decryption techniques including powerful brute force attack are useless against this obfuscation.

  2. Sequential Total Variation Denoising for the Extraction of Fetal ECG from Single-Channel Maternal Abdominal ECG

    PubMed Central

    Lee, Kwang Jin; Lee, Boreom

    2016-01-01

    Fetal heart rate (FHR) is an important determinant of fetal health. Cardiotocography (CTG) is widely used for measuring the FHR in the clinical field. However, fetal movement and blood flow through the maternal blood vessels can critically influence Doppler ultrasound signals. Moreover, CTG is not suitable for long-term monitoring. Therefore, researchers have been developing algorithms to estimate the FHR using electrocardiograms (ECGs) from the abdomen of pregnant women. However, separating the weak fetal ECG signal from the abdominal ECG signal is a challenging problem. In this paper, we propose a method for estimating the FHR using sequential total variation denoising and compare its performance with that of other single-channel fetal ECG extraction methods via simulation using the Fetal ECG Synthetic Database (FECGSYNDB). Moreover, we used real data from PhysioNet fetal ECG databases for the evaluation of the algorithm performance. The R-peak detection rate is calculated to evaluate the performance of our algorithm. Our approach could not only separate the fetal ECG signals from the abdominal ECG signals but also accurately estimate the FHR. PMID:27376296

  3. Sequential Total Variation Denoising for the Extraction of Fetal ECG from Single-Channel Maternal Abdominal ECG.

    PubMed

    Lee, Kwang Jin; Lee, Boreom

    2016-07-01

    Fetal heart rate (FHR) is an important determinant of fetal health. Cardiotocography (CTG) is widely used for measuring the FHR in the clinical field. However, fetal movement and blood flow through the maternal blood vessels can critically influence Doppler ultrasound signals. Moreover, CTG is not suitable for long-term monitoring. Therefore, researchers have been developing algorithms to estimate the FHR using electrocardiograms (ECGs) from the abdomen of pregnant women. However, separating the weak fetal ECG signal from the abdominal ECG signal is a challenging problem. In this paper, we propose a method for estimating the FHR using sequential total variation denoising and compare its performance with that of other single-channel fetal ECG extraction methods via simulation using the Fetal ECG Synthetic Database (FECGSYNDB). Moreover, we used real data from PhysioNet fetal ECG databases for the evaluation of the algorithm performance. The R-peak detection rate is calculated to evaluate the performance of our algorithm. Our approach could not only separate the fetal ECG signals from the abdominal ECG signals but also accurately estimate the FHR.

  4. Comparison of Left Ventricular Hypertrophy by Electrocardiography and Echocardiography in Children Using Analytics Tool.

    PubMed

    Tague, Lauren; Wiggs, Justin; Li, Qianxi; McCarter, Robert; Sherwin, Elizabeth; Weinberg, Jacqueline; Sable, Craig

    2018-05-17

    Left ventricular hypertrophy (LVH) is a common finding on pediatric electrocardiography (ECG) leading to many referrals for echocardiography (echo). This study utilizes a novel analytics tool that combines ECG and echo databases to evaluate ECG as a screening tool for LVH. SQL Server 2012 data warehouse incorporated ECG and echo databases for all patients from a single institution from 2006 to 2016. Customized queries identified patients 0-18 years old with LVH on ECG and an echo performed within 24 h. Using data visualization (Tableau) and analytic (Stata 14) software, ECG and echo findings were compared. Of 437,699 encounters, 4637 met inclusion criteria. ECG had high sensitivity (≥ 90%) but poor specificity (43%), and low positive predictive value (< 20%) for echo abnormalities. ECG performed only 11-22% better than chance (AROC = 0.50). 83% of subjects with LVH on ECG had normal left ventricle (LV) structure and size on echo. African-Americans with LVH were least likely to have an abnormal echo. There was a low correlation between V 6 R on ECG and echo-derived Z score of left ventricle diastolic diameter (r = 0.14) and LV mass index (r = 0.24). The data analytics client was able to mine a database of ECG and echo reports, comparing LVH by ECG and LV measurements and qualitative findings by echo, identifying an abnormal LV by echo in only 17% of cases with LVH on ECG. This novel tool is useful for rapid data mining for both clinical and research endeavors.

  5. Loss of serum IGF-I input to the brain as an early biomarker of disease onset in Alzheimer mice

    PubMed Central

    Trueba-Sáiz, A; Cavada, C; Fernandez, A M; Leon, T; González, D A; Fortea Ormaechea, J; Lleó, A; Del Ser, T; Nuñez, A; Torres-Aleman, I

    2013-01-01

    Circulating insulin-like growth factor I (IGF-I) enters the brain and promotes clearance of amyloid peptides known to accumulate in Alzheimer's disease (AD) brains. Both patients and mouse models of AD show decreased level of circulating IGF-I enter the brain as evidenced by a lower ratio of cerebrospinal fluid/plasma IGF-I. Importantly, in presymptomatic AD mice this reduction is already manifested as a decreased brain input of serum IGF-I in response to environmental enrichment. To explore a potential diagnostic use of this early loss of IGF-I input, we monitored electrocorticogram (ECG) responses to systemic IGF-I in mice. Whereas control mice showed enhanced ECG activity after IGF-I, presymptomatic AD mice showed blunted ECG responses. Because nonhuman primates showed identically enhanced electroencephalogram (EEG) activity in response to systemic IGF-I, loss of the EEG signature of serum IGF-I may be exploited as a disease biomarker in AD patients. PMID:24301648

  6. Ruptured blebs and racing hearts: autonomic cardiac changes in neurosurgeons during microsurgical clipping of aneurysms.

    PubMed

    Ganne, Chaitanya; Talkad, Sathyaprabha N; Srinivas, Dwarakanath; Somanna, Sampath

    2016-08-01

    In this study, we intend to evaluate the autonomic changes occurring in neurosurgeons and thus the stress during microsurgical clipping of aneurysms. The aim of the current study is to evaluate the heart rate variability (HRV) of the neurosurgeons during microsurgical clipping of aneurysm by using continuous real time monitoring of the ECG intraoperatively. Lead II ECG was recorded using Bioharness(®) (Zephyr Technologies, Annapolis, MD) in 4 healthy neurosurgeons who performed 29 microsurgical clipping of aneurysms. ECG from 21 surgeries was analysed (LabChart(®) software, ADInstruments, Dunedin, New Zealand) across five stages: Baseline (BL), sylvian fissure dissection (SFD), perianeurysmal dissection (PAD), clipping of the aneurysm (CLIP) and haemostasis (HEMO). There was a reduction in TP and an increased LF/HF ratio in spite of suppression of both LF and HF powers. Contrary to the common understanding that the sympathetic limb of the autonomic system mostly mediates responses during stress and anxiety, we found that there was a significant contribution of the parasympathetic system too.

  7. Mobile messaging services-based personal electrocardiogram monitoring system.

    PubMed

    Tahat, Ashraf A

    2009-01-01

    A mobile monitoring system utilizing Bluetooth and mobile messaging services (MMS/SMSs) with low-cost hardware equipment is proposed. A proof of concept prototype has been developed and implemented to enable transmission of an Electrocardiogram (ECG) signal and body temperature of a patient, which can be expanded to include other vital signs. Communication between a mobile smart-phone and the ECG and temperature acquisition apparatus is implemented using the popular personal area network standard specification Bluetooth. When utilizing MMS for transmission, the mobile phone plots the received ECG signal and displays the temperature using special application software running on the client mobile phone itself, where the plot can be captured and saved as an image before transmission. Alternatively, SMS can be selected as a transmission means, where in this scenario, dedicated application software is required at the receiving device. The experimental setup can be operated for monitoring from anywhere in the globe covered by a cellular network that offers data services.

  8. Mobile Messaging Services-Based Personal Electrocardiogram Monitoring System

    PubMed Central

    Tahat, Ashraf A.

    2009-01-01

    A mobile monitoring system utilizing Bluetooth and mobile messaging services (MMS/SMSs) with low-cost hardware equipment is proposed. A proof of concept prototype has been developed and implemented to enable transmission of an Electrocardiogram (ECG) signal and body temperature of a patient, which can be expanded to include other vital signs. Communication between a mobile smart-phone and the ECG and temperature acquisition apparatus is implemented using the popular personal area network standard specification Bluetooth. When utilizing MMS for transmission, the mobile phone plots the received ECG signal and displays the temperature using special application software running on the client mobile phone itself, where the plot can be captured and saved as an image before transmission. Alternatively, SMS can be selected as a transmission means, where in this scenario, dedicated application software is required at the receiving device. The experimental setup can be operated for monitoring from anywhere in the globe covered by a cellular network that offers data services. PMID:19707531

  9. [Interobserver agreement on electrocardiographic diagnosis of left ventricular hypertrophy in hypertensive patients in Andalusia. PREHVIA study].

    PubMed

    Martín-Rioboó, Enrique; López Granados, Amador; Cea Calvo, Luis; Pérula De Torres, Luis Angel; García Criado, Emilio; Anguita Sánchez, Manuel P; García Matarín, Lisardo; Molina Díaz, Rafael; Ureña Fernández, Tomas

    2009-05-01

    To assess the agreement between Primary Care (PC) doctors and a cardiology specialist in diagnosing left ventricular hypertrophy in the electrocardiograph (LVH-ECG) in hypertensive patients. Cross-sectional, multicentre study. Andalusian Primary Care Centres. A total of 120 PC doctors who using a random sample selected patients of 35 years or more with AHT of at least 6 months of progression. PRIMARY VARIABLES: Demographic data, risk factors and cardiovascular diseases were recorded. The LVH-ECG was evaluated by applying Cornell voltage criteria, Cornell and Sokolow-Lyon product. The PC researchers read the ECG first and the cardiologist made a second reading blind. A total of 570 patients (mean +/- SD of age, 65 +/- 11 years; 54.5% females); the LVH-ECG prevalence was 13.7% (95% CI, 10.8-16.6; 12.6% by Cornell and 1.6% by Sokolow-Lyon). The agreement in the diagnosis between the PC doctors and the cardiologist was 0.378 (95% CI, 0.272-0.486; disagreements in 15.5% of cases). The PC doctors slightly underestimated the LVH-ECG prevalence by Cornell and slightly overestimated it by the Sokolow-Lyon criteria. The agreement was also low for all of them (kappa = 0.367; 95% CI, 0.252-0.482, for Cornell, and kappa = 0.274; 95% CI: 0.093-0.454 for Sokolow-Lyon). The agreement between the diagnosis by the PC doctors and the cardiologist was low. The implications of this study suggest the need to improve the reading of ECG among PC doctors. The use of computerised systems could be a good option.

  10. Usefulness of simultaneous and sequential monitoring of glucose level and electrocardiogram in monkeys treated with gatifloxacin under conscious and nonrestricted conditions.

    PubMed

    Yoshimatsu, Yu; Ishizaka, Tomomichi; Chiba, Katsuyoshi; Mori, Kazuhiko

    2018-05-10

    Drug-induced cardiac electrophysiological abnormalities accompanied by hypoglycemia or hyperglycemia increase the risk for life-threatening arrhythmia. To assess the drug-induced cardiotoxic potential associated with extraordinary blood glucose (GLU) levels, the effect of gatifloxacin (GFLX) which was frequently associated with GLU abnormality and QT/QTc prolongations in the clinic on blood GLU and electrocardiogram (ECG) parameters was investigated in cynomolgus monkeys (n=4) given GFLX orally in an ascending dose regimen (10, 30, 60 and 100 mg/kg). Simultaneous and sequential GLU and ECG monitoring with a continuous GLU monitoring system and Holter ECG, respectively, were conducted for 24 h under free-moving conditions. Consequently, GFLX at 30 and 60 mg/kg dose-dependently induced a transient decrease in GLU without any ECG abnormality 2-4 h postdose. Highest dose of 100 mg/kg caused severe hypoglycemia with a mean GLU of <30 mg/dL, accompanied by remarkable QT/QTc prolongations by 20-30% in all animals. In contrast, hyperglycemia without QT/QTc prolongations was noted 24 h after dosing in one animal. A close correlation between GLU and QTc values was observed in animals treated with 100 mg/kg, suggesting that GFLX-induced hypoglycemia enhanced QT/QTc prolongations. Furthermore, the 24-h sequential GLU monitoring data clearly distinguished between GFLX-induced GLU abnormality and physiological GLU changes influenced by feeding throughout the day. In conclusion, the combined assessment of continuous GLU and ECG monitoring is valuable in predicting the drug-induced cardio-electrophysiological risk associated with both GLU and ECG abnormalities.

  11. ECG-based 4D-dose reconstruction of cardiac arrhythmia ablation with carbon ion beams: application in a porcine model

    NASA Astrophysics Data System (ADS)

    Richter, Daniel; Immo Lehmann, H.; Eichhorn, Anna; Constantinescu, Anna M.; Kaderka, Robert; Prall, Matthias; Lugenbiel, Patrick; Takami, Mitsuru; Thomas, Dierk; Bert, Christoph; Durante, Marco; Packer, Douglas L.; Graeff, Christian

    2017-09-01

    Noninvasive ablation of cardiac arrhythmia by scanned particle radiotherapy is highly promising, but especially challenging due to cardiac and respiratory motion. Irradiations for catheter-free ablation in intact pigs were carried out at the GSI Helmholtz Center in Darmstadt using scanned carbon ions. Here, we present real-time electrocardiogram (ECG) data to estimate time-resolved (4D) delivered dose. For 11 animals, surface ECGs and temporal structure of beam delivery were acquired during irradiation. R waves were automatically detected from surface ECGs. Pre-treatment ECG-triggered 4D-CT phases were synchronized to the R-R interval. 4D-dose calculation was performed using GSI’s in-house 4D treatment planning system. Resulting dose distributions were assessed with respect to coverage (D95 and V95), heterogeneity (HI  =  D5-D95) and normal tissue exposure. Final results shown here were performed offline, but first calculations were started shortly after irradiation The D95 for TV and PTV was above 95% for 10 and 8 out of 11 animals, respectively. HI was reduced for PTV versus TV volumes, especially for some of the animals targeted at the atrioventricular junction, indicating residual interplay effects due to cardiac motion. Risk structure exposure was comparable to static and 4D treatment planning simulations. ECG-based 4D-dose reconstruction is technically feasible in a patient treatment-like setting. Further development of the presented approach, such as real-time dose calculation, may contribute to safe, successful treatments using scanned ion beams for cardiac arrhythmia ablation.

  12. Resting ECG findings in elite football players.

    PubMed

    Bohm, Philipp; Ditzel, Roman; Ditzel, Heribert; Urhausen, Axel; Meyer, Tim

    2013-01-01

    The purpose of the study was to evaluate ECG abnormalities in a large sample of elite football players. Data from 566 elite male football players (57 of them of African origin) above 16 years of age were screened retrospectively (age: 20.9 ± 5.3 years; BMI: 22.9 ± 1.7 kg · m(-2), training history: 13.8 ± 4.7 years). The resting ECGs were analysed and classified according to the most current ECG categorisation of the European Society of Cardiology (ESC) (2010) and a classification of Pelliccia et al. (2000) in order to assess the impact of the new ESC-approach. According to the classification of Pelliccia, 52.5% showed mildly abnormal ECG patterns and 12% were classified as distinctly abnormal ECG patterns. According to the classification of the ESC, 33.7% showed 'uncommon ECG patterns'. Short-QT interval was the most frequent ECG pattern in this group (41.9%), followed by a shortened PR-interval (19.9%). When assessed with a QTc cut-off-point of 340 ms (instead of 360 ms), only 22.2% would have had 'uncommon ECG patterns'. Resting ECG changes amongst elite football players are common. Adjustment of the ESC criteria by adapting proposed time limits for the ECG (e.g. QTc, PR) should further reduce the rate of false-positive results.

  13. Extended Kalman smoother with differential evolution technique for denoising of ECG signal.

    PubMed

    Panigrahy, D; Sahu, P K

    2016-09-01

    Electrocardiogram (ECG) signal gives a lot of information on the physiology of heart. In reality, noise from various sources interfere with the ECG signal. To get the correct information on physiology of the heart, noise cancellation of the ECG signal is required. In this paper, the effectiveness of extended Kalman smoother (EKS) with the differential evolution (DE) technique for noise cancellation of the ECG signal is investigated. DE is used as an automatic parameter selection method for the selection of ten optimized components of the ECG signal, and those are used to create the ECG signal according to the real ECG signal. These parameters are used by the EKS for the development of the state equation and also for initialization of the parameters of EKS. EKS framework is used for denoising the ECG signal from the single channel. The effectiveness of proposed noise cancellation technique has been evaluated by adding white, colored Gaussian noise and real muscle artifact noise at different SNR to some visually clean ECG signals from the MIT-BIH arrhythmia database. The proposed noise cancellation technique of ECG signal shows better signal to noise ratio (SNR) improvement, lesser mean square error (MSE) and percent of distortion (PRD) compared to other well-known methods.

  14. Advanced Electrocardiography Can Identify Occult Cardiomyopathy in Doberman Pinschers

    NASA Technical Reports Server (NTRS)

    Spiljak, M.; Petric, A. Domanjko; Wilberg, M.; Olsen, L. H.; Stepancic, A.; Schlegel, T. T.; Starc, V.

    2011-01-01

    Recently, multiple advanced resting electrocardiographic (A-ECG) techniques have improved the diagnostic value of short-duration ECG in detection of dilated cardiomyopathy (DCM) in humans. This study investigated whether 12-lead A-ECG recordings could accurately identify the occult phase of DCM in dogs. Short-duration (3-5 min) high-fidelity 12-lead ECG recordings were obtained from 31 privately-owned, clinically healthy Doberman Pinschers (5.4 +/- 1.7 years, 11/20 males/females). Dogs were divided into 2 groups: 1) 19 healthy dogs with normal echocardiographic M-mode measurements: left ventricular internal diameter in diastole (LVIDd . 47mm) and in systole (LVIDs . 38mm) and normal 24-hour ECG recordings (<50 ventricular premature complexes, VPCs); and 2) 12 dogs with occult DCM: 11/12 dogs had increased M-mode measurements (LVIDd . 49mm and/or LVIDs . 40mm) and 5/11 dogs had also >100 VPCs/24h; 1/12 dogs had only abnormal 24-hour ECG recordings (>100 VPCs/24h). ECG recordings were evaluated via custom software programs to calculate multiple parameters of high-frequency (HF) QRS ECG, heart rate variability, QT variability, waveform complexity and 3-D ECG. Student's t-tests determined 19 ECG parameters that were significantly different (P < 0.05) between groups. Principal component factor analysis identified a 5-factor model with 81.4% explained variance. QRS dipolar and non-dipolar voltages, Cornell voltage criteria and QRS waveform residuum were increased significantly (P < 0.05), whereas mean HF QRS amplitude was decreased significantly (P < 0.05) in dogs with occult DCM. For the 5 selected parameters the prediction of occult DCM was performed using a binary logistic regression model with Chi-square tested significance (P < 0.01). ROC analyses showed that the five selected ECG parameters could identify occult ECG with sensitivity 89% and specificity 83%. Results suggest that 12-lead A-ECG might improve diagnostic value of short-duration ECG in earlier detection of canine DCM as five selected ECG parameters can with reasonable accuracy identify occult DCM in Doberman Pinschers. Future extensive clinical studies need to clarify if 12-lead A-ECG could be useful as an additional screening test for canine DCM.

  15. Parametric modelling of cardiac system multiple measurement signals: an open-source computer framework for performance evaluation of ECG, PCG and ABP event detectors.

    PubMed

    Homaeinezhad, M R; Sabetian, P; Feizollahi, A; Ghaffari, A; Rahmani, R

    2012-02-01

    The major focus of this study is to present a performance accuracy assessment framework based on mathematical modelling of cardiac system multiple measurement signals. Three mathematical algebraic subroutines with simple structural functions for synthetic generation of the synchronously triggered electrocardiogram (ECG), phonocardiogram (PCG) and arterial blood pressure (ABP) signals are described. In the case of ECG signals, normal and abnormal PQRST cycles in complicated conditions such as fascicular ventricular tachycardia, rate dependent conduction block and acute Q-wave infarctions of inferior and anterolateral walls can be simulated. Also, continuous ABP waveform with corresponding individual events such as systolic, diastolic and dicrotic pressures with normal or abnormal morphologies can be generated by another part of the model. In addition, the mathematical synthetic PCG framework is able to generate the S4-S1-S2-S3 cycles in normal and in cardiac disorder conditions such as stenosis, insufficiency, regurgitation and gallop. In the PCG model, the amplitude and frequency content (5-700 Hz) of each sound and variation patterns can be specified. The three proposed models were implemented to generate artificial signals with varies abnormality types and signal-to-noise ratios (SNR), for quantitative detection-delineation performance assessment of several ECG, PCG and ABP individual event detectors designed based on the Hilbert transform, discrete wavelet transform, geometric features such as area curve length (ACLM), the multiple higher order moments (MHOM) metric, and the principal components analysed geometric index (PCAGI). For each method the detection-delineation operating characteristics were obtained automatically in terms of sensitivity, positive predictivity and delineation (segmentation) error rms and checked by the cardiologist. The Matlab m-file script of the synthetic ECG, ABP and PCG signal generators are available in the Appendix.

  16. Empirical mode decomposition of the ECG signal for noise removal

    NASA Astrophysics Data System (ADS)

    Khan, Jesmin; Bhuiyan, Sharif; Murphy, Gregory; Alam, Mohammad

    2011-04-01

    Electrocardiography is a diagnostic procedure for the detection and diagnosis of heart abnormalities. The electrocardiogram (ECG) signal contains important information that is utilized by physicians for the diagnosis and analysis of heart diseases. So good quality ECG signal plays a vital role for the interpretation and identification of pathological, anatomical and physiological aspects of the whole cardiac muscle. However, the ECG signals are corrupted by noise which severely limit the utility of the recorded ECG signal for medical evaluation. The most common noise presents in the ECG signal is the high frequency noise caused by the forces acting on the electrodes. In this paper, we propose a new ECG denoising method based on the empirical mode decomposition (EMD). The proposed method is able to enhance the ECG signal upon removing the noise with minimum signal distortion. Simulation is done on the MIT-BIH database to verify the efficacy of the proposed algorithm. Experiments show that the presented method offers very good results to remove noise from the ECG signal.

  17. [Research and design for optimal position of electrocardio-electrodes in monitoring clothing for men].

    PubMed

    Liang, Lijun; Hu, Yao; Liu, Hao; Li, Xiaojiu; Li, Jin; He, Yin

    2017-04-01

    In order to reduce the mortality rate of cardiovascular disease patients effectively, improve the electrocardiogram (ECG) accuracy of signal acquisition, and reduce the influence of motion artifacts caused by the electrodes in inappropriate location in the clothing for ECG measurement, we in this article present a research on the optimum place of ECG electrodes in male clothing using three-lead monitoring methods. In the 3-lead ECG monitoring clothing for men we selected test points. Comparing the ECG and power spectrum analysis of the acquired ECG signal quality of each group of points, we determined the best location of ECG electrodes in the male monitoring clothing. The electrode motion artifacts caused by improper location had been significantly improved when electrodes were put in the best position of the clothing for men. The position of electrodes is crucial for ECG monitoring clothing. The stability of the acquired ECG signal could be improved significantly when electrodes are put at optimal locations.

  18. Artifacts and noise removal in electrocardiograms using independent component analysis.

    PubMed

    Chawla, M P S; Verma, H K; Kumar, Vinod

    2008-09-26

    Independent component analysis (ICA) is a novel technique capable of separating independent components from electrocardiogram (ECG) complex signals. The purpose of this analysis is to evaluate the effectiveness of ICA in removing artifacts and noise from ECG recordings. ICA is applied to remove artifacts and noise in ECG segments of either an individual ECG CSE data base file or all files. The reconstructed ECGs are compared with the original ECG signal. For the four special cases discussed, the R-Peak magnitudes of the CSE data base ECG waveforms before and after applying ICA are also found. In the results, it is shown that in most of the cases, the percentage error in reconstruction is very small. The results show that there is a significant improvement in signal quality, i.e. SNR. All the ECG recording cases dealt showed an improved ECG appearance after the use of ICA. This establishes the efficacy of ICA in elimination of noise and artifacts in electrocardiograms.

  19. Challenges of ECG monitoring and ECG interpretation in dialysis units.

    PubMed

    Poulikakos, Dimitrios; Malik, Marek

    Patients on hemodialysis (HD) suffer from high cardiovascular morbidity and mortality due to high rates of coronary artery disease and arrhythmias. Electrocardiography (ECG) is often performed in the dialysis units as part of routine clinical assessment. However, fluid and electrolyte changes have been shown to affect all ECG morphologies and intervals. ECG interpretation thus depends on the time of the recording in relation to the HD session. In addition, arrhythmias during HD are common, and dialysis-related ECG artifacts mimicking arrhythmias have been reported. Studies using advanced ECG analyses have examined the impact of the HD procedure on selected repolarization descriptors and heart rate variability indices. Despite the challenges related to the impact of the fluctuant fluid and electrolyte status on conventional and advanced ECG parameters, further research in ECG monitoring during dialysis has the potential to provide clinically meaningful and practically useful information for diagnostic and risk stratification purposes. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  20. Implantation of radiotelemetry transmitters yielding data on ECG, heart rate, core body temperature and activity in free-moving laboratory mice.

    PubMed

    Cesarovic, Nikola; Jirkof, Paulin; Rettich, Andreas; Arras, Margarete

    2011-11-21

    The laboratory mouse is the animal species of choice for most biomedical research, in both the academic sphere and the pharmaceutical industry. Mice are a manageable size and relatively easy to house. These factors, together with the availability of a wealth of spontaneous and experimentally induced mutants, make laboratory mice ideally suited to a wide variety of research areas. In cardiovascular, pharmacological and toxicological research, accurate measurement of parameters relating to the circulatory system of laboratory animals is often required. Determination of heart rate, heart rate variability, and duration of PQ and QT intervals are based on electrocardiogram (ECG) recordings. However, obtaining reliable ECG curves as well as physiological data such as core body temperature in mice can be difficult using conventional measurement techniques, which require connecting sensors and lead wires to a restrained, tethered, or even anaesthetized animal. Data obtained in this fashion must be interpreted with caution, as it is well known that restraining and anesthesia can have a major artifactual influence on physiological parameters. Radiotelemetry enables data to be collected from conscious and untethered animals. Measurements can be conducted even in freely moving animals, and without requiring the investigator to be in the proximity of the animal. Thus, known sources of artifacts are avoided, and accurate and reliable measurements are assured. This methodology also reduces interanimal variability, thus reducing the number of animals used, rendering this technology the most humane method of monitoring physiological parameters in laboratory animals. Constant advancements in data acquisition technology and implant miniaturization mean that it is now possible to record physiological parameters and locomotor activity continuously and in realtime over longer periods such as hours, days or even weeks. Here, we describe a surgical technique for implantation of a commercially available telemetry transmitter used for continuous measurements of core body temperature, locomotor activity and biopotential (i.e. onelead ECG), from which heart rate, heart rate variability, and PQ and QT intervals can be established in freeroaming, untethered mice. We also present pre-operative procedures and protocols for post-operative intensive care and pain treatment that improve recovery, well-being and survival rates in implanted mice.

  1. An intelligent health monitoring system using radio-frequency identification technology.

    PubMed

    Lai, Yeong-Lin; Chen, Chin-Ling; Chang, Ching-Hisang; Hsu, Chih-Yu; Lai, Yeong-Kang; Tseng, Kuo-Kun; Chen, Chih-Cheng; Zheng, Chun-Yi

    2015-01-01

    Long-term care (LTC) for the elderly has become extremely important in recent years. It is necessary for the different physiological monitoring systems to be integrated on the same interface to help oversee and manage the elderly's needs. This paper presents a novel health monitoring system for LTC services using radio-frequency identification (RFID) technology. Dual-band RFID protocols were included in the system, in which the high-frequency (HF) band of 13.56 MHz was used to identify individuals and the microwave band of 2.45 GHz was used to monitor physiological information. Distinct physiological data, including oxyhemoglobin saturation by pulse oximetry (SpO2), blood pressure, blood sugar, electrocardiogram (ECG) readings, body temperature, and respiration rate, were monitored by various biosensors. The intelligent RFID health monitoring system provided the features of the real-time acquisition of biomedical signals and the identification of personal information pertaining to the elderly and patients in nursing homes.

  2. Diagnosis and management of adult hereditary cardio-neuromuscular disorders: A model for the multidisciplinary care of complex genetic disorders.

    PubMed

    Sommerville, R Brian; Vincenti, Margherita Guzzi; Winborn, Kathleen; Casey, Anne; Stitziel, Nathan O; Connolly, Anne M; Mann, Douglas L

    2017-01-01

    Genetic disorders that disrupt the structure and function of the cardiovascular system and the peripheral nervous system are common enough to be encountered in routine cardiovascular practice. Although often these patients are diagnosed in childhood and come to the cardiologist fully characterized, some patients with hereditary neuromuscular disease may not manifest until adulthood and will present initially to the adult cardiologist for an evaluation of an abnormal ECG, unexplained syncope, LV hypertrophy, and or a dilated cardiomyopathy of unknown cause. Cardiologists are often ill-equipped to manage these patients due to lack of training and exposure as well as the complete absence of practice guidelines to aid in the diagnosis and management of these disorders. Here, we review three key neuromuscular diseases that affect the cardiovascular system in adults (myotonic dystrophy type 1, Friedreich ataxia, and Emery-Dreifuss muscular dystrophy), with an emphasis on their clinical presentation, genetic and molecular pathogenesis, and recent important research on medical and interventional treatments. We also advocate the development of interdisciplinary cardio-neuromuscular clinics to optimize the care for these patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. MYBPC3 hypertrophic cardiomyopathy can be detected by using advanced ECG in children and young adults.

    PubMed

    Fernlund, E; Liuba, P; Carlson, J; Platonov, P G; Schlegel, T T

    2016-01-01

    The conventional ECG is commonly used to screen for hypertrophic cardiomyopathy (HCM), but up to 25% of adults and possibly larger percentages of children with HCM have no distinctive abnormalities on the conventional ECG, whereas 5 to 15% of healthy young athletes do. Recently, a 5-min resting advanced 12-lead ECG test ("A-ECG score") showed superiority to pooled criteria from the strictly conventional ECG in correctly identifying adult HCM. The purpose of this study was to evaluate whether in children and young adults, A-ECG scoring could detect echocardiographic HCM associated with the MYBPC3 genetic mutation with greater sensitivity than conventional ECG criteria and distinguish healthy young controls and athletes from persons with MYBPC3 HCM with greater specificity. Five-minute 12-lead ECGs were obtained from 15 young patients (mean age 13.2years, range 0-30years) with MYBPC3 mutation and phenotypic HCM. The conventional and A-ECG results of these patients were compared to those of 198 healthy children and young adults (mean age 13.2, range 1month-30years) with unremarkable echocardiograms, and to those of 36 young endurance-trained athletes, 20 of whom had athletic (physiologic) left ventricular hypertrophy. Compared with commonly used, age-specific pooled criteria from the conventional ECG, a retrospectively generated A-ECG score incorporating results from just 2 derived vectorcardiographic parameters (spatial QRS-T angle and the change in the vectorcardiographic QRS azimuth angle from the second to the third eighth of the QRS interval) increased the sensitivity of ECG for identifying MYBPC3 HCM from 46% to 87% (p<0.05). Use of the same score also demonstrated superior specificity in a set of 198 healthy controls (94% vs. 87% for conventional ECG criteria; p<0.01) including in a subset of 36 healthy, young endurance-trained athletes (100% vs. 69% for conventional ECG criteria, p<0.001). In children and young adults, a 2-parameter 12-lead A-ECG score is retrospectively significantly more sensitive and specific than pooled, age-specific conventional ECG criteria for detecting MYBPC3-HCM and in distinguishing such patients from healthy controls, including endurance-trained athletes. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Mobile Monitoring Stations and Web Visualization of Biotelemetric System - Guardian II

    NASA Astrophysics Data System (ADS)

    Krejcar, Ondrej; Janckulik, Dalibor; Motalova, Leona; Kufel, Jan

    The main area of interest of our project is to provide solution which can be used in different areas of health care and which will be available through PDAs (Personal Digital Assistants), web browsers or desktop clients. The realized system deals with an ECG sensor connected to mobile equipment, such as PDA/Embedded, based on Microsoft Windows Mobile operating system. The whole system is based on the architecture of .NET Compact Framework, and Microsoft SQL Server. Visualization possibilities of web interface and ECG data are also discussed and final suggestion is made to Microsoft Silverlight solution along with current screenshot representation of implemented solution. The project was successfully tested in real environment in cryogenic room (-136OC).

  5. Object-oriented integrated approach for the design of scalable ECG systems.

    PubMed

    Boskovic, Dusanka; Besic, Ingmar; Avdagic, Zikrija

    2009-01-01

    The paper presents the implementation of Object-Oriented (OO) integrated approaches to the design of scalable Electro-Cardio-Graph (ECG) Systems. The purpose of this methodology is to preserve real-world structure and relations with the aim to minimize the information loss during the process of modeling, especially for Real-Time (RT) systems. We report on a case study of the design that uses the integration of OO and RT methods and the Unified Modeling Language (UML) standard notation. OO methods identify objects in the real-world domain and use them as fundamental building blocks for the software system. The gained experience based on the strongly defined semantics of the object model is discussed and related problems are analyzed.

  6. Doppler radar sensing of fish physiological motion

    NASA Astrophysics Data System (ADS)

    Hafner, Noah

    The monitoring vital of signs for fish is critical for advancing the study of trophic and energetic strategies, distributions and behavior, environmental impact, and aquaculture approaches. Presented here is a new approach for monitoring fish metabolic state without the trauma and stress associated with capture, surgical ECG, or other implanted sensing systems. Original research contributions include analysis for radar operation under water, development of radar systems for aquatic operation, and application of these systems to non invasively sense the heart and gill motion of fish. Tilapia and Sturgeon were studied to test the efficacy across varied fish body shapes and sizes, ranging from 0.1 to 1.3m in snout to tail length. Monitoring experiments were conducted with eleven tilapia and three sturgeons to assess activity level participated in these experiments, the results from which include activity level monitoring (tilapia: still or fidgeting 94% of time observed), ventilation rate (tilapia: 42 bpm, sturgeon: 145 bpm), and heart rate (tilapia: 41 bpm, sturgeon: 35 bpm). Bland-Altman analysis of radar and ECG measured heart rate indicate agreement between the two measurement techniques and the suitability of radar as an alternative to ECG. The initial steps for developing a system for practical application is also presented including designs for radar system miniaturization and discussion on further characterization steps with less constrained environments.

  7. State of the art techniques for preservation and reuse of hard copy electrocardiograms.

    PubMed

    Lobodzinski, Suave M; Teppner, Ulrich; Laks, Michael

    2003-01-01

    Baseline examinations and periodic reexaminations in longitudinal population studies, together with ongoing surveillance for morbidity and mortality, provide unique opportunities for seeking ways to enhance the value of electrocardiography (ECG) as an inexpensive and noninvasive tool for prognosis and diagnosis. We used newly developed optical ECG waveform recognition (OEWR) technique capable of extracting raw waveform data from legacy hard copy ECG recording. Hardcopy ECG recordings were scanned and processed by the OEWR algorithm. The extracted ECG datasets were formatted into a newly proposed, vendor-neutral, ECG XML data format. Oracle database was used as a repository for ECG records in XML format. The proposed technique for XML encapsulation of OEWR processed hard copy records resulted in an efficient method for inclusion of paper ECG records into research databases, thus providing their preservation, reuse and accession.

  8. Wearable ECG Based on Impulse-Radio-Type Human Body Communication.

    PubMed

    Wang, Jianqing; Fujiwara, Takuya; Kato, Taku; Anzai, Daisuke

    2016-09-01

    Human body communication (HBC) provides a promising physical layer for wireless body area networks (BANs) in healthcare and medical applications, because of its low propagation loss and high security characteristics. In this study, we have developed a wearable electrocardiogram (ECG) which employs impulse radio (IR)-type HBC technology for transmitting vital signals on the human body in a wearable BAN scenario. The HBC-based wearable ECG has two excellent features. First, the wideband performance of the IR scheme contributed to very low radiation power so that the transceiver is easy to satisfy the extremely weak radio laws, which does not need a license. This feature can provide big convenience in the use and spread of the wearable ECG. Second, the realization of common use of sensing and transmitting electrodes based on time sharing and capacitive coupling largely simplified the HBC-based ECG structure and contributed to its miniaturization. To verify the validity of the HBC-based ECG, we evaluated its communication performance and ECG acquisition performance. The measured bit error rate, smaller than 10 -3 at 1.25 Mb/s, showed a good physical layer communication performance, and the acquired ECG waveform and various heart-rate variability parameters in time and frequency domains exhibited good agreement with a commercially available radio-frequency ECG and a Holter ECG. These results sufficiently showed the validity and feasibility of the HBC-based ECG for healthcare applications. This should be the first time to have realized a real-time ECG transmission by using the HBC technology.

  9. Variable Association between Components of the Metabolic Syndrome and Electrocardiographic Abnormalities in Korean Adults

    PubMed Central

    Kim, Chul-Hee; Ko, Kwan-Ho; Park, Seong-Wook; Park, Joong-Yeol; Lee, Ki-Up

    2010-01-01

    Background/Aims Resting electrocardiogram (ECG) abnormalities have been strongly associated with cardiovascular disease mortality. Little is known, however, about the association between individual components of metabolic syndrome and ECG abnormalities, especially in Asian populations. Methods We examined clinical and laboratory data from 31,399 subjects (age 20 to 89 years) who underwent medical check-ups. ECG abnormalities were divided into minor and major abnormalities based on Novacode criteria. Ischemic ECG findings were separately identified and analyzed. Results The overall prevalence rates of ECG abnormalities were significantly higher in subjects with than in those without metabolic syndrome (p < 0.01). Ischemic ECG was strongly associated with metabolic syndrome in all age groups of both sexes, except for younger women. In multiple logistic regression analysis, metabolic syndrome was independently associated with ischemic ECG (odds ratio, 2.30 [2.04 to 2.62]; p < 0.01), after adjusting for sex, age, smoking, and family history of cardiovascular disease. Of the metabolic syndrome components, hyperglycemia in younger subjects and hypertension in elderly subjects were major factors for ischemic ECG changes, whereas hypertriglyceridemia was not an independent risk factor in any age group. The association between ischemic ECG findings and central obesity was weaker in women than in men. Conclusions Metabolic syndrome was strongly associated with ECG abnormalities, especially ischemic ECG findings, in Koreans. The association between each component of metabolic syndrome and ECG abnormalities varied according to age and sex. PMID:20526391

  10. Are ECG abnormalities in Noonan syndrome characteristic for the syndrome?

    PubMed

    Raaijmakers, R; Noordam, C; Noonan, J A; Croonen, E A; van der Burgt, C J A M; Draaisma, J M T

    2008-12-01

    Of all patients with Noonan syndrome, 50-90% have one or more congenital heart defects. The most frequent occurring are pulmonary stenosis (PS) and hypertrophic cardiomyopathy. The electrocardiogram (ECG) of a patient with Noonan syndrome often shows a characteristic pattern, with a left axis deviation, abnormal R/S ratio over the left precordium, and an abnormal Q wave. The objective of this study was to determine if these ECG characteristics are an independent feature of the Noonan syndrome or if they are related to the congenital heart defect. A cohort study was performed with 118 patients from two university hospitals in the United States and in The Netherlands. All patients were diagnosed with definite Noonan syndrome and had had an ECG and echocardiography. Sixty-nine patients (58%) had characteristic abnormalities of the ECG. In the patient group without a cardiac defect (n = 21), ten patients had a characteristic ECG abnormality. There was no statistical relationship between the presence of a characteristic ECG abnormality and the presence of a cardiac defect (p = 0.33). Patients with hypertrophic cardiomyopathy had more ECG abnormalities in total (p = 0.05), without correlation with a specific ECG abnormality. We conclude that the ECG features in patients with Noonan syndrome are characteristic for the syndrome and are not related to a specific cardiac defect. An ECG is very useful in the diagnosis of Noonan syndrome; every child with a Noonan phenotype should have an ECG and echocardiogram for evaluation.

  11. Abnormalities of the QT interval in primary disorders of autonomic failure

    NASA Technical Reports Server (NTRS)

    Choy, A. M.; Lang, C. C.; Roden, D. M.; Robertson, D.; Wood, A. J.; Robertson, R. M.; Biaggioni, I.

    1998-01-01

    BACKGROUND: Experimental evidence shows that activation of the autonomic nervous system influences ventricular repolarization and, therefore, the QT interval on the ECG. To test the hypothesis that the QT interval is abnormal in autonomic dysfunction, we examined ECGs in patients with severe primary autonomic failure and in patients with congenital dopamine beta-hydroxylase (DbetaH) deficiency who are unable to synthesize norepinephrine and epinephrine. SUBJECTS AND METHODS: Maximal QT and rate-corrected QT (QTc) intervals and adjusted QTc dispersion [(maximal QTc - minimum QTc on 12 lead ECG)/square root of the number of leads measured] were determined in blinded fashion from ECGs of 67 patients with primary autonomic failure (36 patients with multiple system atrophy [MSA], and 31 patients with pure autonomic failure [PAF]) and 17 age- and sex-matched healthy controls. ECGs of 5 patients with congenital DbetaH deficiency and 6 age- and sex-matched controls were also analyzed. RESULTS: Patients with MSA and PAF had significantly prolonged maximum QTc intervals (492+/-58 ms(1/2) and 502+/-61 ms(1/2) [mean +/- SD]), respectively, compared with controls (450+/-18 ms(1/2), P < .05 and P < .01, respectively). A similar but not significant trend was observed for QT. QTc dispersion was also increased in MSA (40+/-20 ms(1/2), P < .05 vs controls) and PAF patients (32+/-19 ms(1/2), NS) compared with controls (21+/-5 ms(1/2)). In contrast, patients with congenital DbetaH deficiency did not have significantly different RR, QT, QTc intervals, or QTc dispersion when compared with controls. CONCLUSIONS: Patients with primary autonomic failure who have combined parasympathetic and sympathetic failure have abnormally prolonged QT interval and increased QT dispersion. However, QT interval in patients with congenital DbetaH deficiency was not significantly different from controls. It is possible, therefore, that QT abnormalities in patients with primary autonomic failure are not solely caused by lesions of the sympathetic nervous system, and that the parasympathetic nervous system is likely to have a modulatory role in ventricular repolarization.

  12. Beat-ID: Towards a computationally low-cost single heartbeat biometric identity check system based on electrocardiogram wave morphology

    PubMed Central

    Paiva, Joana S.; Dias, Duarte

    2017-01-01

    In recent years, safer and more reliable biometric methods have been developed. Apart from the need for enhanced security, the media and entertainment sectors have also been applying biometrics in the emerging market of user-adaptable objects/systems to make these systems more user-friendly. However, the complexity of some state-of-the-art biometric systems (e.g., iris recognition) or their high false rejection rate (e.g., fingerprint recognition) is neither compatible with the simple hardware architecture required by reduced-size devices nor the new trend of implementing smart objects within the dynamic market of the Internet of Things (IoT). It was recently shown that an individual can be recognized by extracting features from their electrocardiogram (ECG). However, most current ECG-based biometric algorithms are computationally demanding and/or rely on relatively large (several seconds) ECG samples, which are incompatible with the aforementioned application fields. Here, we present a computationally low-cost method (patent pending), including simple mathematical operations, for identifying a person using only three ECG morphology-based characteristics from a single heartbeat. The algorithm was trained/tested using ECG signals of different duration from the Physionet database on more than 60 different training/test datasets. The proposed method achieved maximal averaged accuracy of 97.450% in distinguishing each subject from a ten-subject set and false acceptance and rejection rates (FAR and FRR) of 5.710±1.900% and 3.440±1.980%, respectively, placing Beat-ID in a very competitive position in terms of the FRR/FAR among state-of-the-art methods. Furthermore, the proposed method can identify a person using an average of 1.020 heartbeats. It therefore has FRR/FAR behavior similar to obtaining a fingerprint, yet it is simpler and requires less expensive hardware. This method targets low-computational/energy-cost scenarios, such as tiny wearable devices (e.g., a smart object that automatically adapts its configuration to the user). A hardware proof-of-concept implementation is presented as an annex to this paper. PMID:28719614

  13. Beat-ID: Towards a computationally low-cost single heartbeat biometric identity check system based on electrocardiogram wave morphology.

    PubMed

    Paiva, Joana S; Dias, Duarte; Cunha, João P S

    2017-01-01

    In recent years, safer and more reliable biometric methods have been developed. Apart from the need for enhanced security, the media and entertainment sectors have also been applying biometrics in the emerging market of user-adaptable objects/systems to make these systems more user-friendly. However, the complexity of some state-of-the-art biometric systems (e.g., iris recognition) or their high false rejection rate (e.g., fingerprint recognition) is neither compatible with the simple hardware architecture required by reduced-size devices nor the new trend of implementing smart objects within the dynamic market of the Internet of Things (IoT). It was recently shown that an individual can be recognized by extracting features from their electrocardiogram (ECG). However, most current ECG-based biometric algorithms are computationally demanding and/or rely on relatively large (several seconds) ECG samples, which are incompatible with the aforementioned application fields. Here, we present a computationally low-cost method (patent pending), including simple mathematical operations, for identifying a person using only three ECG morphology-based characteristics from a single heartbeat. The algorithm was trained/tested using ECG signals of different duration from the Physionet database on more than 60 different training/test datasets. The proposed method achieved maximal averaged accuracy of 97.450% in distinguishing each subject from a ten-subject set and false acceptance and rejection rates (FAR and FRR) of 5.710±1.900% and 3.440±1.980%, respectively, placing Beat-ID in a very competitive position in terms of the FRR/FAR among state-of-the-art methods. Furthermore, the proposed method can identify a person using an average of 1.020 heartbeats. It therefore has FRR/FAR behavior similar to obtaining a fingerprint, yet it is simpler and requires less expensive hardware. This method targets low-computational/energy-cost scenarios, such as tiny wearable devices (e.g., a smart object that automatically adapts its configuration to the user). A hardware proof-of-concept implementation is presented as an annex to this paper.

  14. Methods for Improving the Diagnosis of a Brugada ECG Pattern.

    PubMed

    Gottschalk, Byron H; Garcia-Niebla, Javier; Anselm, Daniel D; Glover, Benedict; Baranchuk, Adrian

    2016-03-01

    Brugada syndrome (BrS) is an inherited channelopathy that predisposes individuals to malignant arrhythmias and can lead to sudden cardiac death. The condition is characterized by two electrocardiography (ECG) patterns: the type-1 or "coved" ECG and the type-2 or "saddleback" ECG. Although the type-1 Brugada ECG pattern is diagnostic for the condition, the type-2 Brugada ECG pattern requires differential diagnosis from conditions that produce a similar morphology. In this article, we present a case that is suspicious but not diagnostic for BrS and discuss the application of ECG methodologies for increasing or decreasing suspicion for a diagnosis of BrS. © 2015 Wiley Periodicals, Inc.

  15. Feasibility of in utero telemetric fetal ECG monitoring in a lamb model.

    PubMed

    Hermans, Bart; Lewi, Liesbeth; Jani, Jacques; De Buck, Frederik; Deprest, Jan; Puers, Robert

    2008-01-01

    If fetal ECG (fECG) devices could be miniaturized sufficiently, one could consider their implantation at the time of fetal surgery to allow permanent monitoring of the fetus and timely intervention in the viable period. We set up an experiment to evaluate the feasibility of in utero direct fECG monitoring and telemetric transmission using a small implantable device in a lamb model. A 2-lead miniature ECG sensor (volume 1.9 cm(3); weight 3.9 g) was subcutaneously implanted in 2 fetal lambs at 122 days gestation (range 119-125; term 145 days). The ECG sensor can continuously register and transmit fECG. The signal is captured by an external receiving antenna taped to the maternal abdominal wall. We developed dedicated software running on a commercial laptop for on-line analysis of the transmitted fECG signal. This was a noninterventional study, i.e. daily readings of the fECG signal were done without clinical consequences to the observations. fECG could be successfully registered, transmitted by telemetry and analyzed from the moment of implantation till term birth in one case (24 days). In the second case, unexplained in utero fetal death occurred 12 days after implantation. In this subject, agonal fECG changes were recorded. An implanted miniature (<2 ml) ECG sensor can be used to retrieve, process and transmit continuously a qualitative fECG signal in third-trimester fetal lambs. The telemetric signal could be picked up by an external antenna located within a 20-cm range. In this experiment, this was achieved through taping the external receiver to the maternal abdomen. Any acquired signal could be transmitted to a commercially available laptop that could perform on-line analysis of the signal. (c) 2008 S. Karger AG, Basel.

  16. Female False Positive Exercise Stress ECG Testing - Fact Verses Fiction.

    PubMed

    Fitzgerald, Benjamin T; Scalia, William M; Scalia, Gregory M

    2018-03-07

    Exercise stress testing is a well validated cardiovascular investigation. Accuracy for treadmill stress electrocardiograph (ECG) testing has been documented at 60%. False positive stress ECGs (exercise ECG changes with non-obstructive disease on anatomical testing) are common, especially in women, limiting the effectiveness of the test. This study investigates the incidence and predictors of false positive stress ECG findings, referenced against stress echocardiography (SE) as a standard. Stress echocardiography was performed using the Bruce treadmill protocol. False positive stress ECG tests were defined as greater than 1mm of ST depression on ECG during exertion, without pain, with a normal SE. Potential causes for false positive tests were recorded before the test. Three thousand consecutive negative stress echocardiograms (1036 females, 34.5%) were analysed (age 59+/-14 years. False positive (F+) stress ECGs were documented in 565/3000 tests (18.8%). F+ stress ECGs were equally prevalent in females (194/1036, 18.7%) and males (371/1964, 18.9%, p=0.85 for the difference). Potential causes (hypertension, left ventricular hypertrophy, known coronary disease, arrhythmia, diabetes mellitus, valvular heart disease) were recorded in 36/194 (18.6%) of the female F+ ECG tests and 249/371 (68.2%) of the male F+ ECG tests (p<0.0001 for the difference). These data suggest that F+ stress ECG tests are frequent and equally common in women and men. However, most F+ stress ECGs in men can be predicted before the test, while most in women cannot. Being female may be a risk factor in itself. These data reinforce the value of stress imaging, particularly in women. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

  17. Future cardiac events in patients with ischemic ECG changes during adenosine infusion as a myocardial stress agent and normal cardiac scan.

    PubMed

    Amer, Hamid; Niaz, Khalid; Hatazawa, Jun; Gasmelseed, Ahmed; Samiri, Hussain Al; Al Othman, Maram; Hammad, Mai Al

    2017-11-01

    We sought to determine the prognostic importance of adenosine-induced ischemic ECG changes in patients with normal single-photon emission computed tomography myocardial perfusion images (MPI). We carried out a retrospective analysis of 765 patients undergoing adenosine MPI between January 2013 and January 2015. Patients with baseline ECG abnormalities and/or abnormal scan were excluded. Overall, 67 (8.7%) patients had ischemic ECG changes during adenosine infusion in the form of ST depression of 1 mm or more. Of these, 29 [43% (3.8% of all patients)] had normal MPI (positive ECG group). An age-matched and sex-matched group of 108 patients with normal MPI without ECG changes served as control participants (negative ECG group). During a mean follow-up duration of 33.3±6.1 months, patients in the positive ECG group did not have significantly more adverse cardiac events than those in the negative ECG group. One (0.9%) patient in the negative ECG group had a nonfatal myocardial infarction (0.7% annual event rate after a negative MPI). Also in this group, two (1.8%) patients admitted with a diagnosis of CAD where they have been ruled out by angiography. A fourth case in this, in the negative ECG group, was admitted because of heart failure that proved to be secondary to a pulmonary cause and not CAD. A case only in the positive ECG group was admitted as a CAD that was ruled out by coronary angiography. Patients with normal myocardial perfusion scintigraphy in whom ST-segment depression develops during adenosine stress test appear to have no increased risk for future cardiac events compared with similar patients without ECG evidence of ischemia.

  18. Bedside identification of patients at risk for PVC-induced cardiomyopathy: Is ECG useful?

    PubMed

    Garster, Noelle C; Henrikson, Charles A

    2017-07-01

    Premature ventricular complexes (PVCs) are an underrecognized cause of cardiomyopathy. Standard 12-lead electrocardiogram (ECG) has potential to direct attention toward at-risk patients. We performed a single-center, retrospective chart review of 1,240 patients who completed ECG and Holter monitoring at Oregon Health and Science University Hospital between January 1, 2011 and December 31, 2013 to investigate the relationship of PVC frequency on ECG with burden on Holter. Primary outcome measures included PVC quantity on ECG, mean PVC quantity on Holter, and percentage of total beats on Holter recorded as PVCs. High PVC burden was defined as ≥10% of total beats. Weighted mean percentages of total beats on Holter monitor recorded as PVCs were calculated for 0, 1, 2, and ≥3 PVCs on ECG and found to be 1.4% (n = 1,128), 3.5% (n = 32), 4.3% (n = 25), and 16.6% (n = 55), respectively, which represent statistically significant differences (P < 0.001). The positive predictive value of at least three PVCs on ECG for ≥10% PVC Holter burden was 58%. Negative predictive value for 0 PVCs on ECG was 98%. The sensitivity and specificity of ECG to identify high PVC burden on Holter was 72% and 93.6%, respectively, when utilizing a positive ECG result as one PVC or more, and 44% and 98.9%, respectively, with ≥3 PVCs on ECG. The positive likelihood ratio corresponding to ≥3 PVCs on ECG was 40. These findings demonstrate that the number of PVCs on ECG can be utilized for quick bedside estimation of high PVC burden. © 2017 Wiley Periodicals, Inc.

  19. Pilot study analyzing automated ECG screening of hypertrophic cardiomyopathy.

    PubMed

    Campbell, Matthew J; Zhou, Xuefu; Han, Chia; Abrishami, Hedayat; Webster, Gregory; Miyake, Christina Y; Sower, Christopher T; Anderson, Jeffrey B; Knilans, Timothy K; Czosek, Richard J

    2017-06-01

    Hypertrophic cardiomyopathy (HCM) is one of the leading causes of sudden cardiac death in athletes. However, preparticipation ECG screening has often been criticized for failing to meet cost-effectiveness thresholds, in part because of high false-positive rates and the cost of ECG screening itself. The purpose of this study was to assess the testing characteristics of an automated ECG algorithm designed to screen for HCM in a multi-institutional pediatric cohort. ECGs from patients with HCM aged 12 to 20 years from 3 pediatric institutions were screened for ECG criteria for HCM using a previously described automated computer algorithm developed specifically for HCM ECG screening. The results were compared to a known healthy pediatric cohort. The studies then were read by trained electrophysiologists using standard ECG criteria and compared to the results of automated screening. One hundred twenty-eight ECGs from unique patients with phenotypic HCM were obtained and compared with 256 studies from healthy control patients matched in 2:1 fashion. When presented with the ECGs, the non-voltage-based algorithm resulted in 81.2% sensitivity and 90.7% specificity. A trained electrophysiologist read the same data according to the Seattle Criteria, with 71% sensitivity with 95.7% specificity. The sensitivity of screening as well as the components of the ECG screening itself varied by institution. This pilot study demonstrates a potential for automated ECG screening algorithms to detect HCM with testing characteristics similar to that of a trained electrophysiologist. In addition, there appear to be differences in ECG characteristics between patient populations, which may account for the difficulties in universal screening. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  20. Association between use of pre-hospital ECG and 30-day mortality: A large cohort study of patients experiencing chest pain.

    PubMed

    Rawshani, Nina; Rawshani, Araz; Gelang, Carita; Herlitz, Johan; Bång, Angela; Andersson, Jan-Otto; Gellerstedt, Martin

    2017-12-01

    In the assessment of patients with chest pain, there is support for the use of pre-hospital ECG in the literature and in the care guidelines. Using propensity score methods, we aim to examine whether the mere acquisition of a pre-hospital ECG among patients with chest pain affects the outcome (30-day mortality). The association between pre-hospital ECG and 30-day mortality was studied in the overall cohort (n=13151), as well as in the one-to-one matched cohort with 2524 patients not examined with pre-hospital ECG and 2524 patients examined with pre-hospital ECG. In the overall cohort, 21% (n=2809) did not undergo an ECG tracing in the pre-hospital setting. Among those who had pain during transport, 14% (n=1159) did not undergo a pre-hospital ECG while 32% (n=1135) of those who did not have pain underwent an ECG tracing. In the overall cohort, the OR for 30-day mortality in patients who had a pre-hospital ECG, as compared with those who did not, was 0.63 (95% CI 0.05-0.79; p<0.001). In the matched cohort, the OR was 0.65 (95% CI 0.49-0.85; p<0.001). Using the propensity score, in the overall cohort, the corresponding HR was 0.65 (95% CI 0.58-0.74). Using propensity score methods, we provide real-world data demonstrating that the adjusted risk of death was considerably lower among the cases in whoma pre-hospital ECG was used. The PH-ECG is underused among patients with chest discomfort and the mere acquisition of a pre-hospital ECG may reduce mortality. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Physician attitudes about prehospital 12-lead ECGs in chest pain patients.

    PubMed

    Brainard, Andrew H; Froman, Philip; Alarcon, Maria E; Raynovich, Bill; Tandberg, Dan

    2002-01-01

    The prehospital 12-lead electrocardiogram (ECG) has become a standard of care. For the prehospital 12-lead ECG to be useful clinically, however, cardiologists and emergency physicians (EP) must view the test as useful. This study measured physician attitudes about the prehospital 12-lead ECG. This study tested the hypothesis that physicians had "no opinion" regarding the prehospital 12-lead ECG. An anonymous survey was conducted to measure EP and cardiologist attitudes toward prehospital 12-lead ECGs. Hypothesis tests against "no opinion" (VAS = 50 mm) were made with 95% confidence intervals (CIs), and intergroup comparisons were made with the Student's t-test. Seventy-one of 87 (81.6%) surveys were returned. Twenty-five (67.6%) cardiologists responded and 45 (90%) EPs responded. Both groups of physicians viewed prehospital 12-lead ECGs as beneficial (mean = 69 mm; 95% CI = 65-74 mm). All physicians perceived that ECGs positively influence preparation of staff (mean = 63 mm; 95% CI = 60-72 mm) and that ECGs transmitted to hospitals would be beneficial (mean = 66 mm; 95% CI = 60-72 mm). Cardiologists had more favorable opinions than did EPs. The ability of paramedics to interpret ECGs was not seen as important (mean = 50 mm; 95% CI = 43-56 mm). The justifiable increase in field time was perceived to be 3.2 minutes (95% CI = 2.7-3.8 minutes), with 23 (32.8%) preferring that it be done on scene, 46 (65.7%) during transport, and one (1.4%) not at all. Prehospital 12-lead ECGs generally are perceived as worthwhile by cardiologists and EPs. Cardiologists have a higher opinion of the value and utility of field ECGs. Since the reduction in mortality from the 12-lead ECG is small, it is likely that positive physician attitudes are attributable to other factors.

  2. CAVIAR: a serial ECG processing system for the comparative analysis of VCGs and their interpretation with auto-reference to the patient.

    PubMed

    Fayn, J; Rubel, P

    1988-01-01

    The authors present a new computer program for serial ECG analysis that allows a direct comparison of any couple of three-dimensional ECGs and quantitatively assesses the degree of evolution of the spatial loops as well as of their initial, central, or terminal sectors. Loops and sectors are superposed as best as possible, with the aim of overcoming tracing variability of nonpathological origin. As a result, optimal measures of evolution are computed and a tabular summary of measurements is dynamically configured with respect to the patient's history and is then printed. A multivariate classifier assigns each couple of tracings to one of four classes of evolution. Color graphic displays corresponding to several modes of representation may also be plotted.

  3. Expert Systems In Medical Studies - A New Twist

    NASA Astrophysics Data System (ADS)

    Slagle, James R.; Long, John M.; Wick, Michael R.; Matts, John P.; Leon, Arthur S.

    1986-03-01

    The use of experts to evaluate large amounts of trial data results in increasingly expensive and time consuming research. We are investigating the role expert systems can play in reducing the time and expense of research projects. Current methods in large clinical studies for evaluating data are often crude and superficial. We have developed, for a large clinical trial, an expert system for analysis of treadmill exercise ECG test results. In the cases we are studying, a patient is given a treadmill exercise ECG test once a year for five years. Pairs of these exercise tests are then evaluated by cardiologists to determine the condition of the patient's heart. The results of our system show great promise for the use of expert systems in reducing the time and expense of large clinical trials.

  4. Predictable and reliable ECG monitoring over IEEE 802.11 WLANs within a hospital.

    PubMed

    Park, Juyoung; Kang, Kyungtae

    2014-09-01

    Telecardiology provides mobility for patients who require constant electrocardiogram (ECG) monitoring. However, its safety is dependent on the predictability and robustness of data delivery, which must overcome errors in the wireless channel through which the ECG data are transmitted. We report here a framework that can be used to gauge the applicability of IEEE 802.11 wireless local area network (WLAN) technology to ECG monitoring systems in terms of delay constraints and transmission reliability. For this purpose, a medical-grade WLAN architecture achieved predictable delay through the combination of a medium access control mechanism based on the point coordination function provided by IEEE 802.11 and an error control scheme based on Reed-Solomon coding and block interleaving. The size of the jitter buffer needed was determined by this architecture to avoid service dropout caused by buffer underrun, through analysis of variations in transmission delay. Finally, we assessed this architecture in terms of service latency and reliability by modeling the transmission of uncompressed two-lead electrocardiogram data from the MIT-BIH Arrhythmia Database and highlight the applicability of this wireless technology to telecardiology.

  5. Biomarkers and electrocardiographic evidence of myocardial ischemia in patients with human immunodeficiency virus infection.

    PubMed

    Gupta, Mihir; Miller, Christopher J; Baker, Jason V; Lazar, Jason; Bogner, Johannes R; Calmy, Alexandra; Soliman, Elsayed Z; Neaton, James D

    2013-03-01

    We assessed the relation of inflammatory and coagulation biomarkers with electrocardiographic (ECG) evidence of myocardial ischemia. High-sensitivity C-reactive protein (hsCRP), interleukin-6 (IL-6), and D-dimer levels were measured at study entry for 3,085 human immunodeficiency virus-infected participants (mean age 44 years; 26.4% women; 24.6% black) in the Strategies for Management of Antiretroviral Therapy trial. Logistic regression models were used to examine the associations of these biomarkers with prevalent and incident myocardial ischemia. The latter analyses were performed for 1,411 participants who were randomly assigned to receive continuous antiretroviral therapy during follow-up to suppress the human immunodeficiency virus viral load and had ≥1 ECG reading during the follow-up period. The median hsCRP, IL-6, and D-dimer level was 1.65 μg/ml (interquartile range 0.69 to 4.11), 1.60 pg/ml (interquartile range 1.00 to 2.75), and 0.18 μg/ml (interquartile range 0.11 to 0.32), respectively. At baseline, the prevalence of major or minor Q-QS or ST-T ECG abnormalities was 18.6%. The biomarker levels were associated with prevalent major or minor ischemic abnormalities on the univariate analyses; however, adjustment for traditional risk factors attenuated these associations. The adjusted odds ratio for major or minor ischemic abnormalities and 95% confidence intervals for the greatest versus lowest quartiles was 1.3 (95% confidence interval 0.9 to 1.7) for hsCRP, 1.0 (95% confidence interval 0.7 to 1.3) for IL-6, and 1.1 (95% confidence interval 0.9 to 1.5) for D-dimer. During a median follow-up of 2.3 years, new definite or probable ischemic ECG abnormalities developed in 11.7% of participants receiving continuous antiretroviral therapy. Biomarker levels were not associated with incident abnormalities on unadjusted or adjusted analyses. In conclusion, higher levels of hsCRP, IL-6, and D-dimer were not associated with ischemic ECG abnormalities. Elevated biomarker levels and ECG abnormalities indicating myocardial ischemia might reflect different risk pathways for cardiovascular disease. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Mobile Cardiac Health-care Monitoring and Notification with Real Time Tachycardia and Bradycardia Arrhythmia Detection

    PubMed Central

    Golzar, Mina; Fotouhi-Ghazvini, Faranak; Rabbani, Hossein; Zakeri, Fahimeh Sadat

    2017-01-01

    Background: The increasing trend of heart disease has turned the attention of researchers toward the use of portable connected technologies. The necessity of continuous special care for cardiovascular patients is an inevitable fact. Methods: In this research, a new wireless electrocardiographic (ECG) signal-monitoring system based on smartphone is presented. This system has two main sections. The first section consists of a sensor which receives ECG signals via an amplifier, then filters and digitizes the signal, and prepares it to be transmitted. The signals are stored, processed, and then displayed in a mobile application. The application alarms in dangerous situations and sends the location of the cardiac patient to family or health-care staff. Results: The results obtained from the analysis of the electrocardiogram signals on 20 different people have been compared with the traditional ECG in hospital by a cardiologist. The signal is instantly transmitted by 200 sample per second to mobile phone. The raw data are processed, the anomaly is detected, and the signal is drawn on the interface in about 70 s. Therefore, the delay is not noticeable by the patient. With respect to rate of data transmission to hospital, different internet connections such as 2G, 3G, 4G, WiFi, WiMax, or Long-Term Evolution (LTE) could be used. Data transmission ranges from 9.6 kbps to 20 Mbps. Therefore, the physician could receive data with no delay. Conclusions: A performance accuracy of 91.62% is obtained from the wireless ECG system. It conforms to the hospital's diagnostic standard system while providing a portable monitoring anywhere at anytime. PMID:29204376

  7. Public access defibrillation: Suppression of 16.7 Hz interference generated by the power supply of the railway systems

    PubMed Central

    Christov, Ivaylo I; Iliev, Georgi L

    2005-01-01

    Background A specific problem using the public access defibrillators (PADs) arises at the railway stations. Some countries as Germany, Austria, Switzerland, Norway and Sweden are using AC railroad net power-supply system with rated 16.7 Hz frequency modulated from 15.69 Hz to 17.36 Hz. The power supply frequency contaminates the electrocardiogram (ECG). It is difficult to be suppressed or eliminated due to the fact that it considerably overlaps the frequency spectra of the ECG. The interference impedes the automated decision of the PADs whether a patient should be (or should not be) shocked. The aim of this study is the suppression of the 16.7 Hz interference generated by the power supply of the railway systems. Methods Software solution using adaptive filtering method was proposed for 16.7 Hz interference suppression. The optimal performance of the filter is achieved, embedding a reference channel in the PADs to record the interference. The method was tested with ECGs from AHA database. Results The method was tested with patients of normal sinus rhythms, symptoms of tachycardia and ventricular fibrillation. Simulated interference with frequency modulation from 15.69 Hz to 17.36 Hz changing at a rate of 2% per second was added to the ECGs, and then processed by the suggested adaptive filtering. The method totally suppresses the noise with no visible distortions of the original signals. Conclusion The proposed adaptive filter for noise suppression generated by the power supply of the railway systems has a simple structure requiring a low level of computational resources, but a good reference signal as well. PMID:15766390

  8. Sparse Matrix for ECG Identification with Two-Lead Features.

    PubMed

    Tseng, Kuo-Kun; Luo, Jiao; Hegarty, Robert; Wang, Wenmin; Haiting, Dong

    2015-01-01

    Electrocardiograph (ECG) human identification has the potential to improve biometric security. However, improvements in ECG identification and feature extraction are required. Previous work has focused on single lead ECG signals. Our work proposes a new algorithm for human identification by mapping two-lead ECG signals onto a two-dimensional matrix then employing a sparse matrix method to process the matrix. And that is the first application of sparse matrix techniques for ECG identification. Moreover, the results of our experiments demonstrate the benefits of our approach over existing methods.

  9. Automatic detection of ECG cable interchange by analyzing both morphology and interlead relations.

    PubMed

    Han, Chengzong; Gregg, Richard E; Feild, Dirk Q; Babaeizadeh, Saeed

    2014-01-01

    ECG cable interchange can generate erroneous diagnoses. For algorithms detecting ECG cable interchange, high specificity is required to maintain a low total false positive rate because the prevalence of interchange is low. In this study, we propose and evaluate an improved algorithm for automatic detection and classification of ECG cable interchange. The algorithm was developed by using both ECG morphology information and redundancy information. ECG morphology features included QRS-T and P-wave amplitude, frontal axis and clockwise vector loop rotation. The redundancy features were derived based on the EASI™ lead system transformation. The classification was implemented using linear support vector machine. The development database came from multiple sources including both normal subjects and cardiac patients. An independent database was used to test the algorithm performance. Common cable interchanges were simulated by swapping either limb cables or precordial cables. For the whole validation database, the overall sensitivity and specificity for detecting precordial cable interchange were 56.5% and 99.9%, and the sensitivity and specificity for detecting limb cable interchange (excluding left arm-left leg interchange) were 93.8% and 99.9%. Defining precordial cable interchange or limb cable interchange as a single positive event, the total false positive rate was 0.7%. When the algorithm was designed for higher sensitivity, the sensitivity for detecting precordial cable interchange increased to 74.6% and the total false positive rate increased to 2.7%, while the sensitivity for detecting limb cable interchange was maintained at 93.8%. The low total false positive rate was maintained at 0.6% for the more abnormal subset of the validation database including only hypertrophy and infarction patients. The proposed algorithm can detect and classify ECG cable interchanges with high specificity and low total false positive rate, at the cost of decreased sensitivity for certain precordial cable interchanges. The algorithm could also be configured for higher sensitivity for different applications where a lower specificity can be tolerated. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Heartbeat detection in multimodal physiological signals using signal quality assessment based on sample entropy.

    PubMed

    Singh, Omkar; Sunkaria, Ramesh Kumar

    2017-12-01

    This paper presents a novel technique to identify heartbeats in multimodal data using electrocardiogram (ECG) and arterial blood pressure (ABP) signals. Multiple physiological signals such as ECG, ABP, and Respiration are often recorded in parallel from the activity of heart. These signals generally possess related information as they are generated by the same physical system. The ECG and ABP correspond to the same phenomenon of contraction and relaxation activity of heart. Multiple signals acquired from various sensors are generally processed independently, thus discarding the information from other measurements. In the estimation of heart rate and heart rate variability, the R peaks are generally identified from ECG signal. Efficient detection of R-peaks in electrocardiogram (ECG) is a key component in the estimation of clinically relevant parameters from ECG. However, when the signal is severely affected by undesired artifacts, this becomes a challenging task. Sometimes in clinical environment, other physiological signals reflecting the cardiac activity such as ABP signal are also acquired simultaneously. Under the availability of such multimodal signals, the accuracy of R peak detection methods can be improved using sensor-fusion techniques. In the proposed method, the sample entropy (SampEn) is used as a metric for assessing the noise content in the physiological signal and the R peaks in ECG and the systolic peaks in ABP signals are fused together to enhance the efficiency of heartbeat detection. The proposed method was evaluated on the 100 records from the computing in cardiology challenge 2014 training data set. The performance parameters are: sensitivity (Se) and positive predictivity (PPV). The unimodal R peaks detector achieved: Se gross = 99.40%, PPV gross = 99.29%, Se average = 99.37%, PPV average = 99.29%. Similarly unimodal BP delineator achieved Se gross = 99.93%, PPV gross = 99.99%, Se average = 99.93%, PPV average = 99.99% whereas, the proposed multimodal beat detector achieved: Se gross = 99.65%, PPV gross = 99.91%, Se average = 99.68%, PPV average = 99.91%.

  11. Electrocardiogram Abnormalities and Coronary Calcification in Postmenopausal Women

    PubMed Central

    Sabour, Siamak; Grobbee, Diederick; Rutten, Annemarieke; Prokop, Mathias; Bartelink, Marie-Louise; van der Schouw, Yvonne; Bots, Michiel

    2010-01-01

    Background: An electrocardiogram (ECG) can provide information on subclinical myocardial damage. The presence, and more importantly, the quantity of coronary artery calcification (CAC), relates well with the overall severity of the atherosclerotic process. A strong relation has been demonstrated between coronary calcium burden and the incidence of myocardial infarction, a relation independent of age. The aim of this study was to assess the relation of left ventricular hypertrophy (LVH) and ECG abnormalities with CAC. Methods: The study population comprised 566 postmenopausal women selected from a population-based cohort study. Information on LVH and repolarization abnormalities (T-axis and QRS-T angle) was obtained using electrocardiography. Modular ECG Analysis System (MEANS) was used to assess ECG abnormalities. The women underwent a multi detector-row computed tomography (MDCT) scan (Philips Mx 8000 IDT 16) to assess CAC. The Agatston score was used to quantify CAC; scores greater than zero were considered as the presence of coronary calcium. Logistic regression was used to assess the relation of ECG abnormality with coronary calcification. Results: LVH was found in 2.7% (n = 15) of the women. The prevalence of T-axis abnormality was 6% (n = 34), whereas 8.5% (n = 48) had a QRS-T angle abnormality. CAC was found in 62% of the women. Compared to women with a normal T-axis, women with borderline or abnormal T-axes were 3.8 fold more likely to have CAC (95% CI: 1.4–10.2). Similarly, compared to women with a normal QRS-T angle, in women with borderline or abnormal QRS-T angle, CAC was 2.0 fold more likely to be present (95% CI: 1.0–4.1). Conclusion: Among women with ECG abnormalities reflecting subclinical ischemia, CAC is commonly found and may in part explain the increased coronary heart disease risk associated with these ECG abnormalities. PMID:23074563

  12. Helical prospective ECG-gating in cardiac computed tomography: radiation dose and image quality.

    PubMed

    DeFrance, Tony; Dubois, Eric; Gebow, Dan; Ramirez, Alex; Wolf, Florian; Feuchtner, Gudrun M

    2010-01-01

    Helical prospective ECG-gating (pECG) may reduce radiation dose while maintaining the advantages of helical image acquisition for coronary computed tomography angiography (CCTA). Aim of this study was to evaluate helical pECG-gating in CCTA in regards to radiation dose and image quality. 86 patients undergoing 64-multislice CCTA were enrolled. pECG-gating was performed in patients with regular heart rates (HR) < 65 bpm; with the gating window set at 70-85% of the cardiac cycle. All patients received oral and some received additional IV beta-blockers to achieve HR < 65 bpm. In patients with higher or irregular HR, or for functional evaluation, retrospective ECG-gating (rECG) was performed. The average X-ray dose was estimated from the dose length product. Each arterial segment (modified AHA/ACC 17-segment-model) was evaluated on a 4-point image quality scale (4 = excellent; 3 = good, mild artefact; 2 = acceptable, some artefact, 1 = uninterpretable). pECG-gating was applied in 57 patients, rECG-gating in 29 patients. There was no difference in age, gender, body mass index, scan length or tube output settings between both groups. HR in the pECG-group was 54.7 bpm (range, 43-64). The effective radiation dose was significantly lower for patients scanned with pECG-gating with mean 6.9 mSv +/- 1.9 (range, 2.9-10.7) compared to rECG with 16.9 mSv +/- 4.1 (P < 0.001), resulting in a mean dose reduction of 59.2%. For pECG-gating, out of 969 coronary segments, 99.3% were interpretable. Image quality was excellent in 90.2%, good in 7.8%, acceptable in 1.3% and non-interpretable in 0.7% (n = 7 segments). For patients with steady heart rates <65 bpm, helical prospective ECG-gating can significantly lower the radiation dose while maintaining high image quality.

  13. New ideas for teaching electrocardiogram interpretation and improving classroom teaching content.

    PubMed

    Zeng, Rui; Yue, Rong-Zheng; Tan, Chun-Yu; Wang, Qin; Kuang, Pu; Tian, Pan-Wen; Zuo, Chuan

    2015-01-01

    Interpreting an electrocardiogram (ECG) is not only one of the most important parts of diagnostics but also one of the most difficult areas to teach. Owing to the abstract nature of the basic theoretical knowledge of the ECG, its scattered characteristics, and tedious and difficult-to-remember subject matter, teaching how to interpret ECGs is as difficult for teachers to teach as it is for students to learn. In order to enable medical students to master basic knowledge of ECG interpretation skills in a limited teaching time, we modified the content used for traditional ECG teaching and now propose a new ECG teaching method called the "graphics-sequence memory method." A prospective randomized controlled study was designed to measure the actual effectiveness of ECG learning by students. Two hundred students were randomly placed under a traditional teaching group and an innovative teaching group, with 100 participants in each group. The teachers in the traditional teaching group utilized the traditional teaching outline, whereas the teachers in the innovative teaching group received training in line with the proposed teaching method and syllabus. All the students took an examination in the final semester by analyzing 20 ECGs from real clinical cases and submitted their ECG reports. The average ECG reading time was 32 minutes for the traditional teaching group and 18 minutes for the innovative teaching group. The average ECG accuracy results were 43% for the traditional teaching group and 77% for the innovative teaching group. Learning to accurately interpret ECGs is an important skill in the cardiac discipline, but the ECG's mechanisms are intricate and the content is scattered. Textbooks tend to make the students feel confused owing to the restrictions of the length and the format of the syllabi, apart from many other limitations. The graphics-sequence memory method was found to be a useful method for ECG teaching.

  14. Brugada Syndrome

    MedlinePlus

    ... A telltale abnormality — called a type 1 Brugada ECG pattern — is detected by an electrocardiogram (ECG) test. Brugada syndrome is much more common in ... syndrome is an abnormal pattern on an electrocardiogram (ECG) called a type 1 Brugada ECG pattern. You ...

  15. Image-guided optimization of the ECG trace in cardiac MRI.

    PubMed

    Barnwell, James D; Klein, J Larry; Stallings, Cliff; Sturm, Amanda; Gillespie, Michael; Fine, Jason; Hyslop, W Brian

    2012-03-01

    Improper electrocardiogram (ECG) lead placement resulting in suboptimal gating may lead to reduced image quality in cardiac magnetic resonance imaging (CMR). A patientspecific systematic technique for rapid optimization of lead placement may improve CMR image quality. A rapid 3 dimensional image of the thorax was used to guide the realignment of ECG leads relative to the cardiac axis of the patient in forty consecutive adult patients. Using our novel approach and consensus reading of pre- and post-correction ECG traces, seventy-three percent of patients had a qualitative improvement in their ECG tracings, and no patient had a decrease in quality of their ECG tracing following the correction technique. Statistically significant improvement was observed independent of gender, body mass index, and cardiac rhythm. This technique provides an efficient option to improve the quality of the ECG tracing in patients who have a poor quality ECG with standard techniques.

  16. Multiscale permutation entropy analysis of electrocardiogram

    NASA Astrophysics Data System (ADS)

    Liu, Tiebing; Yao, Wenpo; Wu, Min; Shi, Zhaorong; Wang, Jun; Ning, Xinbao

    2017-04-01

    To make a comprehensive nonlinear analysis to ECG, multiscale permutation entropy (MPE) was applied to ECG characteristics extraction to make a comprehensive nonlinear analysis of ECG. Three kinds of ECG from PhysioNet database, congestive heart failure (CHF) patients, healthy young and elderly subjects, are applied in this paper. We set embedding dimension to 4 and adjust scale factor from 2 to 100 with a step size of 2, and compare MPE with multiscale entropy (MSE). As increase of scale factor, MPE complexity of the three ECG signals are showing first-decrease and last-increase trends. When scale factor is between 10 and 32, complexities of the three ECG had biggest difference, entropy of the elderly is 0.146 less than the CHF patients and 0.025 larger than the healthy young in average, in line with normal physiological characteristics. Test results showed that MPE can effectively apply in ECG nonlinear analysis, and can effectively distinguish different ECG signals.

  17. ECG interpretation in Emergency Department residents: an update and e-learning as a resource to improve skills.

    PubMed

    Barthelemy, Francois X; Segard, Julien; Fradin, Philippe; Hourdin, Nicolas; Batard, Eric; Pottier, Pierre; Potel, Gilles; Montassier, Emmanuel

    2017-04-01

    ECG interpretation is a pivotal skill to acquire during residency, especially for Emergency Department (ED) residents. Previous studies reported that ECG interpretation competency among residents was rather low. However, the optimal resource to improve ECG interpretation skills remains unclear. The aim of our study was to compare two teaching modalities to improve the ECG interpretation skills of ED residents: e-learning and lecture-based courses. The participants were first-year and second-year ED residents, assigned randomly to the two groups. The ED residents were evaluated by means of a precourse test at the beginning of the study and a postcourse test after the e-learning and lecture-based courses. These evaluations consisted of the interpretation of 10 different ECGs. We included 39 ED residents from four different hospitals. The precourse test showed that the overall average score of ECG interpretation was 40%. Nineteen participants were then assigned to the e-learning course and 20 to the lecture-based course. Globally, there was a significant improvement in ECG interpretation skills (accuracy score=55%, P=0.0002). However, this difference was not significant between the two groups (P=0.14). Our findings showed that the ECG interpretation was not optimal and that our e-learning program may be an effective tool for enhancing ECG interpretation skills among ED residents. A large European study should be carried out to evaluate ECG interpretation skills among ED residents before the implementation of ECG learning, including e-learning strategies, during ED residency.

  18. Prolonged corrected QT interval is predictive of future stroke events even in subjects without ECG-diagnosed left ventricular hypertrophy.

    PubMed

    Ishikawa, Joji; Ishikawa, Shizukiyo; Kario, Kazuomi

    2015-03-01

    We attempted to evaluate whether subjects who exhibit prolonged corrected QT (QTc) interval (≥440 ms in men and ≥460 ms in women) on ECG, with and without ECG-diagnosed left ventricular hypertrophy (ECG-LVH; Cornell product, ≥244 mV×ms), are at increased risk of stroke. Among the 10 643 subjects, there were a total of 375 stroke events during the follow-up period (128.7±28.1 months; 114 142 person-years). The subjects with prolonged QTc interval (hazard ratio, 2.13; 95% confidence interval, 1.22-3.73) had an increased risk of stroke even after adjustment for ECG-LVH (hazard ratio, 1.71; 95% confidence interval, 1.22-2.40). When we stratified the subjects into those with neither a prolonged QTc interval nor ECG-LVH, those with a prolonged QTc interval but without ECG-LVH, and those with ECG-LVH, multivariate-adjusted Cox proportional hazards analysis demonstrated that the subjects with prolonged QTc intervals but not ECG-LVH (1.2% of all subjects; incidence, 10.7%; hazard ratio, 2.70, 95% confidence interval, 1.48-4.94) and those with ECG-LVH (incidence, 7.9%; hazard ratio, 1.83; 95% confidence interval, 1.31-2.57) had an increased risk of stroke events, compared with those with neither a prolonged QTc interval nor ECG-LVH. In conclusion, prolonged QTc interval was associated with stroke risk even among patients without ECG-LVH in the general population. © 2014 American Heart Association, Inc.

  19. Determining factors of electrocardiographic abnormalities in patients with epilepsy: A case-control study.

    PubMed

    de Sousa, Jorge Murilo Barbosa; Fialho, Guilherme Loureiro; Wolf, Peter; Walz, Roger; Lin, Katia

    2017-01-01

    Sudden unexpected death in epilepsy (SUDEP) is a major cause of mortality in young patients with epilepsy (PWE). Although its mechanisms are still poorly understood, they may include cardiorespiratory dysfunction. Standard 12-lead electrocardiograms (ECGs) were obtained from 62 consecutive patients (aged 18-66y) with a definite diagnosis of epilepsy, without seizures at the day of ECG, and 57 healthy controls matched for sex, age and body mass index (BMI). All ECGs were evaluated by a blinded board-certified cardiologist. Patients with symptomatic focal epilepsy represented 90.3% (N=56), of whom 56.4% (N=35) had temporal lobe epilepsy, with a mean duration of 22.02±14.96years of epilepsy. We observed more prolonged P-wave (p<0.0001) and PR interval (p=0.01) in patients than in controls. Additionally, longer QT intervals (p<0.01), pathologic QT dispersion (p<0.01) and left atrial overload (p<0.01) were more common in PWE. Multiple linear regression analysis evidenced age, gender and polytherapy as factors associated with altered ECG. Therefore, routine ECG should be requested in PWE, especially for males, increasing age and in polytherapy. Findings such as longer PR and QT interval, and pathologic QT dispersion, may reflect cardiac structural changes and/or autonomic nervous system dysfunction and indicate a risk for SUDEP. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Heart Rhythm Monitoring in the Constellation Lunar and Launch/Landing EVA Suit: Recommendations from an Expert Panel

    NASA Technical Reports Server (NTRS)

    Scheuring, Richard A.; Hamilton, Doug; Jones, Jeffrey A.; Alexander, David

    2009-01-01

    There are currently several physiological monitoring requirements for EVA in the Human-Systems Interface Requirements (HSIR) document. There are questions as to whether the capability to monitor heart rhythm in the lunar surface space suit is a necessary capability for lunar surface operations. Similarly, there are questions as to whether the capability to monitor heart rhythm during a cabin depressurization scenario in the launch/landing space suit is necessary. This presentation seeks to inform space medicine personnel of recommendations made by an expert panel of cardiovascular medicine specialists regarding in-suit ECG heart rhythm monitoring requirements during lunar surface operations. After a review of demographic information and clinical cases and panel discussion, the panel recommended that ECG monitoring capability as a clinical tool was not essential in the lunar space suit; ECG monitoring was not essential in the launch/landing space suit for contingency scenarios; the current hear rate monitoring capability requirement for both launch/landing and lunar space suits should be maintained; lunar vehicles should be required to have ECG monitoring capability with a minimum of 5-lead ECG for IVA medical assessments; and, exercise stress testing for astronaut selection and retention should be changed from the current 85% maximum heart rate limit to maximal, exhaustive 'symptom-limited' testing to maximize diagnostic utility as a screening tool for evaluating the functional capacity of astronauts and their cardiovascular health.

  1. Fast clustering algorithm for large ECG data sets based on CS theory in combination with PCA and K-NN methods.

    PubMed

    Balouchestani, Mohammadreza; Krishnan, Sridhar

    2014-01-01

    Long-term recording of Electrocardiogram (ECG) signals plays an important role in health care systems for diagnostic and treatment purposes of heart diseases. Clustering and classification of collecting data are essential parts for detecting concealed information of P-QRS-T waves in the long-term ECG recording. Currently used algorithms do have their share of drawbacks: 1) clustering and classification cannot be done in real time; 2) they suffer from huge energy consumption and load of sampling. These drawbacks motivated us in developing novel optimized clustering algorithm which could easily scan large ECG datasets for establishing low power long-term ECG recording. In this paper, we present an advanced K-means clustering algorithm based on Compressed Sensing (CS) theory as a random sampling procedure. Then, two dimensionality reduction methods: Principal Component Analysis (PCA) and Linear Correlation Coefficient (LCC) followed by sorting the data using the K-Nearest Neighbours (K-NN) and Probabilistic Neural Network (PNN) classifiers are applied to the proposed algorithm. We show our algorithm based on PCA features in combination with K-NN classifier shows better performance than other methods. The proposed algorithm outperforms existing algorithms by increasing 11% classification accuracy. In addition, the proposed algorithm illustrates classification accuracy for K-NN and PNN classifiers, and a Receiver Operating Characteristics (ROC) area of 99.98%, 99.83%, and 99.75% respectively.

  2. QT Interval Prolongation and QRS Voltage Reduction in Patients with Liver Cirrhosis.

    PubMed

    Cichoż-Lach, Halina; Tomaszewski, Michał; Kowalik, Agnieszka; Lis, Emilia; Tomaszewski, Andrzej; Lach, Tomasz; Boczkowska, Sylwia; Celiński, Krzysztof

    2015-01-01

    Liver cirrhosis is associated with functional abnormalities of the cardiovascular system with co-existing electrocardiographic (ECG) abnormalities. The aim was to analyze ECG changes in patients with cirrhosis, to evaluate whether alcoholic etiology of cirrhosis and ascites has an impact on ECG changes. The study involved 81 patients with previously untreated alcoholic cirrhosis (64 patients with ascites, classes B and C according to the Child-Pugh classification; and 17 without ascites, categorized as class A); 41 patients with previously untreated cirrhosis due to chronic hepatitis C (HCV--30 patients with ascites, classes B and C; and 11 without ascites, class A); 42 with alcoholic steatohepatitis and 46 with alcoholic steatosis. The control group consisted of 32 healthy volunteers. Twelve-lead ECG recordings were performed and selected parameters were measured. Significantly longer QT and QTc intervals and lower QRS voltage were found in patients with alcoholic and HCV cirrhosis compared to the controls. Significantly lower QRS voltage was found in subjects with ascites than in those without ascites. Removal of ascites significantly increased QRS voltage. In cirrhosis, irrespective of etiology, ECG changes involved prolonged QT and QTc intervals and reduced QRS voltage. Prolonged QT and QTc intervals were not related to the severity of cirrhosis or to the presence of ascites. However, low QRS voltage was associated with the presence of ascites. Removal of ascites reverses low QRS voltage.

  3. Extraction of ECG signal with adaptive filter for hearth abnormalities detection

    NASA Astrophysics Data System (ADS)

    Turnip, Mardi; Saragih, Rijois. I. E.; Dharma, Abdi; Esti Kusumandari, Dwi; Turnip, Arjon; Sitanggang, Delima; Aisyah, Siti

    2018-04-01

    This paper demonstrates an adaptive filter method for extraction ofelectrocardiogram (ECG) feature in hearth abnormalities detection. In particular, electrocardiogram (ECG) is a recording of the heart's electrical activity by capturing a tracingof cardiac electrical impulse as it moves from the atrium to the ventricles. The applied algorithm is to evaluate and analyze ECG signals for abnormalities detection based on P, Q, R and S peaks. In the first phase, the real-time ECG data is acquired and pre-processed. In the second phase, the procured ECG signal is subjected to feature extraction process. The extracted features detect abnormal peaks present in the waveform. Thus the normal and abnormal ECG signal could be differentiated based on the features extracted.

  4. A mobile monitoring system of blood pressure for underserved in China by information and communication technology service.

    PubMed

    Jiang, Jiehui; Yan, Zhuangzhi; Kandachar, Prabhu; Freudenthal, Adinda

    2010-05-01

    High blood pressure (BP, hypertension) is a leading chronic condition in China and has become the main risk factor for many high-risk diseases, such as heart attacks. However, the platform for chronic disease measurement and management is still lacking, especially for underserved Chinese. To achieve the early diagnosis of hypertension, one BP monitoring system has been designed. The proposed design consists of three main parts: user domain, server domain, and channel domain. All three units and their materialization, validation tests on reliability, and usability are described in this paper, and the conclusion is that the current design concept is feasible and the system can be developed toward sufficient reliability and affordability with further optimization. This idea might also be extended into one platform for other physiological signals, such as blood sugar and ECG.

  5. Frequency Band Analysis of Electrocardiogram (ECG) Signals for Human Emotional State Classification Using Discrete Wavelet Transform (DWT)

    PubMed Central

    Murugappan, Murugappan; Murugappan, Subbulakshmi; Zheng, Bong Siao

    2013-01-01

    [Purpose] Intelligent emotion assessment systems have been highly successful in a variety of applications, such as e-learning, psychology, and psycho-physiology. This study aimed to assess five different human emotions (happiness, disgust, fear, sadness, and neutral) using heart rate variability (HRV) signals derived from an electrocardiogram (ECG). [Subjects] Twenty healthy university students (10 males and 10 females) with a mean age of 23 years participated in this experiment. [Methods] All five emotions were induced by audio-visual stimuli (video clips). ECG signals were acquired using 3 electrodes and were preprocessed using a Butterworth 3rd order filter to remove noise and baseline wander. The Pan-Tompkins algorithm was used to derive the HRV signals from ECG. Discrete wavelet transform (DWT) was used to extract statistical features from the HRV signals using four wavelet functions: Daubechies6 (db6), Daubechies7 (db7), Symmlet8 (sym8), and Coiflet5 (coif5). The k-nearest neighbor (KNN) and linear discriminant analysis (LDA) were used to map the statistical features into corresponding emotions. [Results] KNN provided the maximum average emotion classification rate compared to LDA for five emotions (sadness − 50.28%; happiness − 79.03%; fear − 77.78%; disgust − 88.69%; and neutral − 78.34%). [Conclusion] The results of this study indicate that HRV may be a reliable indicator of changes in the emotional state of subjects and provides an approach to the development of a real-time emotion assessment system with a higher reliability than other systems. PMID:24259846

  6. Frequency Band Analysis of Electrocardiogram (ECG) Signals for Human Emotional State Classification Using Discrete Wavelet Transform (DWT).

    PubMed

    Murugappan, Murugappan; Murugappan, Subbulakshmi; Zheng, Bong Siao

    2013-07-01

    [Purpose] Intelligent emotion assessment systems have been highly successful in a variety of applications, such as e-learning, psychology, and psycho-physiology. This study aimed to assess five different human emotions (happiness, disgust, fear, sadness, and neutral) using heart rate variability (HRV) signals derived from an electrocardiogram (ECG). [Subjects] Twenty healthy university students (10 males and 10 females) with a mean age of 23 years participated in this experiment. [Methods] All five emotions were induced by audio-visual stimuli (video clips). ECG signals were acquired using 3 electrodes and were preprocessed using a Butterworth 3rd order filter to remove noise and baseline wander. The Pan-Tompkins algorithm was used to derive the HRV signals from ECG. Discrete wavelet transform (DWT) was used to extract statistical features from the HRV signals using four wavelet functions: Daubechies6 (db6), Daubechies7 (db7), Symmlet8 (sym8), and Coiflet5 (coif5). The k-nearest neighbor (KNN) and linear discriminant analysis (LDA) were used to map the statistical features into corresponding emotions. [Results] KNN provided the maximum average emotion classification rate compared to LDA for five emotions (sadness - 50.28%; happiness - 79.03%; fear - 77.78%; disgust - 88.69%; and neutral - 78.34%). [Conclusion] The results of this study indicate that HRV may be a reliable indicator of changes in the emotional state of subjects and provides an approach to the development of a real-time emotion assessment system with a higher reliability than other systems.

  7. Sustained Performance of a "Physicianless" System of Automated Prehospital STEMI Diagnosis and Catheterization Laboratory Activation.

    PubMed

    Potter, Brian J; Matteau, Alexis; Mansour, Samer; Naim, Charbel; Riahi, Mounir; Essiambre, Richard; Montigny, Martine; Sareault, Isabelle; Gobeil, François

    2017-01-01

    Treatment times for primary percutaneous coronary intervention frequently exceed the recommended maximum delay. Automated "physicianless" systems of prehospital cardiac catheterization laboratory (CCL) activation show promise, but have been met with resistance over concerns regarding the potential for false positive and inappropriate activations (IAs). From 2010 to 2015, first responders performed electrocardiograms (ECGs) in the field for all patients with a complaint of chest pain or dyspnea. An automated machine diagnosis of "acute myocardial infarction" resulted in immediate CCL activation and direct transfer without transmission or human reinterpretation of the ECG prior to patient arrival. Any activation resulting from a nondiagnostic ECG (no ST-elevation) was deemed an IA, whereas activations resulting from ECG's compatible with ST-elevation myocardial infarction but without angiographic evidence of a coronary event were deemed false positive. In 2012, the referral algorithm was modified to exclude supraventricular tachycardia and left bundle branch block. There were 155 activations in the early cohort (2010-2012; prior to algorithm modification) and 313 in the late cohort (2012-2015). Algorithm modification resulted in a 42% relative decrease in the rate of IAs (12% vs 7%; P < 0.01) without a significant effect on treatment delay. A combination of prehospital automated ST-elevation myocardial infarction diagnosis and "physicianless" CCL activation is safe and effective in improving treatment delay and these results are sustainable over time. The performance of the referral algorithm in terms of IA and false positive is at least on par with systems that ensure real-time human oversight. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  8. Electrocardiogram findings in emergency department patients with syncope.

    PubMed

    Quinn, James; McDermott, Daniel

    2011-07-01

    To determine the sensitivity and specificity of the San Francisco Syncope Rule (SFSR) electrocardiogram (ECG) criteria for determining cardiac outcomes and to define the specific ECG findings that are the most important in patients with syncope. A consecutive cohort of emergency department (ED) patients with syncope or near syncope was considered. The treating emergency physicians assessed 50 predictor variables, including an ECG and rhythm assessment. For the ECG assessment, the physicians were asked to categorize the ECG as normal or abnormal based on any changes that were old or new. They also did a separate rhythm assessment and could use any of the ECGs or available monitoring strips, including prehospital strips, when making this assessment. All patients were followed up to determine a broad composite study outcome. The final ECG criterion for the SFSR was any nonsinus rhythm or new ECG changes. In this specific study, the initial assessments in the database were used to determine only cardiac-related outcomes (arrhythmia, myocardial infarction, structural, sudden death) based on set criteria, and the authors determined the sensitivity and specificity of the ECG criteria for cardiac outcomes only. All ECGs classified as "abnormal" by the study criteria were compared to the official cardiology reading to determine specific findings on the ECG. Univariate and multivariate analysis were used to determine important specific ECG and rhythm findings. A total of 684 consecutive patients were considered, with 218 having positive ECG criteria and 42 (6%) having important cardiac outcomes. ECG criteria predicted 36 of 42 patients with cardiac outcomes, with a sensitivity of 86% (95% confidence interval [CI] = 71% to 94%), a specificity of 70% (95% CI = 66% to 74%), and a negative predictive value of 99% (95% CI = 97% to 99%). Regarding specific ECG findings, any nonsinus rhythm from any source and any left bundle conduction problem (i.e., any left bundle branch block, left anterior fascicular block, left posterior fascicular block, or QRS widening) were 2.5 and 3.5 times more likely associated with significant cardiac outcomes. The ECG criteria from the SFSR are relatively simple, and if used correctly can help predict which patients are at risk of cardiac outcomes. Furthermore, any left bundle branch block conduction problems or any nonsinus rhythms found during the ED stay should be especially concerning for physicians caring for patients presenting with syncope. © 2011 by the Society for Academic Emergency Medicine.

  9. FastICA peel-off for ECG interference removal from surface EMG.

    PubMed

    Chen, Maoqi; Zhang, Xu; Chen, Xiang; Zhu, Mingxing; Li, Guanglin; Zhou, Ping

    2016-06-13

    Multi-channel recording of surface electromyographyic (EMG) signals is very likely to be contaminated by electrocardiographic (ECG) interference, specifically when the surface electrode is placed on muscles close to the heart. A novel fast independent component analysis (FastICA) based peel-off method is presented to remove ECG interference contaminating multi-channel surface EMG signals. Although demonstrating spatial variability in waveform shape, the ECG interference in different channels shares the same firing instants. Utilizing the firing information estimated from FastICA, ECG interference can be separated from surface EMG by a "peel off" processing. The performance of the method was quantified with synthetic signals by combining a series of experimentally recorded "clean" surface EMG and "pure" ECG interference. It was demonstrated that the new method can remove ECG interference efficiently with little distortion to surface EMG amplitude and frequency. The proposed method was also validated using experimental surface EMG signals contaminated by ECG interference. The proposed FastICA peel-off method can be used as a new and practical solution to eliminating ECG interference from multichannel EMG recordings.

  10. Improvement of emotional healthcare system with stress detection from ECG signal.

    PubMed

    Tivatansakul, S; Ohkura, M

    2015-01-01

    Our emotional healthcare system is designed to cope with users' negative emotions in daily life. To make the system more intelligent, we integrated emotion recognition by facial expression to provide appropriate services based on user's current emotional state. Our emotion recognition by facial expression has confusion issue to recognize some positive, neutral and negative emotions that make the emotional healthcare system provide a relaxation service even though users don't have negative emotions. Therefore, to increase the effectiveness of the system to provide the relaxation service, we integrate stress detection from ECG signal. The stress detection might be able to address the confusion issue of emotion recognition by facial expression to provide the service. Indeed, our results show that integration of stress detection increases the effectiveness and efficiency of the emotional healthcare system to provide services.

  11. A Low-Power Bio-Potential Acquisition System with Flexible PDMS Dry Electrodes for Portable Ubiquitous Healthcare Applications

    PubMed Central

    Chen, Chih-Yuan; Chang, Chia-Lin; Chang, Chih-Wei; Lai, Shin-Chi; Chien, Tsung-Fu; Huang, Hong-Yi; Chiou, Jin-Chern; Luo, Ching-Hsing

    2013-01-01

    This work describes a bio-potential acquisition system for portable ubiquitous healthcare applications using flexible polydimethylsiloxane dry electrodes (FPDEs) and a low-power recording circuit. This novel FPDE used Au as the skin contact layer, which was made using a CO2 laser and replica method technology. The FPDE was revised from a commercial bio-potential electrode with a conductive snap using dry electrodes rather than wet electrodes that proposed reliable and robust attachment for the purpose of measurement, and attaching velcro made it wearable on the forearm for bio-potential applications. Furthermore, this study proposes a recording device to store bio-potential signal data and provides portability and low-power consumption for the proposed acquisition system. To acquire differential bio-potentials, such as electrocardiogram (ECG) signals, the proposed recording device includes a low-power front-end acquisition chip fabricated using a complementary metal-oxide-semiconductor (CMOS) process, a commercial microcontroller (MSP430F149), and a secure digital (SD) card for portable healthcare applications. The proposed system can obtain ECG signals efficiently and are comfortable to the skin. The power consumption of the system is about 85 mW for continuous working over a 3 day period with two AA batteries. It can also be used as a compact Holter ECG system. PMID:23459390

  12. Resting electrocardiogram and stress myocardial perfusion imaging in the determination of left ventricular systolic function: an assessment enhancing the performance of gated SPET.

    PubMed

    Moralidis, Efstratios; Spyridonidis, Tryfon; Arsos, Georgios; Skeberis, Vassilios; Anagnostopoulos, Constantinos; Gavrielidis, Stavros

    2010-01-01

    This study aimed to determine systolic dysfunction and estimate resting left ventricular ejection fraction (LVEF) from information collected during routine evaluation of patients with suspected or known coronary heart disease. This approach was then compared to gated single photon emission tomography (SPET). Patients having undergone stress (201)Tl myocardial perfusion imaging followed by equilibrium radionuclide angiography (ERNA) were separated into derivation (n=954) and validation (n=309) groups. Logistic regression analysis was used to develop scoring systems, containing clinical, electrocardiographic (ECG) and scintigraphic data, for the discrimination of an ERNA-LVEF<0.50. Linear regression analysis provided equations predicting ERNA-LVEF from those scores. In 373 patients LVEF was also assessed with (201)Tl gated SPET. Our results showed that an ECG-Scintigraphic scoring system was the best simple predictor of an ERNA-LVEF<0.50 in comparison to other models including ECG, clinical and scintigraphic variables in both the derivation and validation subpopulations. A simple linear equation was derived also for the assessment of resting LVEF from the ECG-Scintigraphic model. Equilibrium radionuclide angiography-LVEF had a good correlation with the ECG-Scintigraphic model LVEF (r=0.716, P=0.000), (201)Tl gated SPET LVEF (r=0.711, P=0.000) and the average LVEF from those assessments (r=0.796, P=0.000). The Bland-Altman statistic (mean+/-2SD) provided values of 0.001+/-0.176, 0.071+/-0.196 and 0.040+/-0.152, respectively. The average LVEF was a better discriminator of systolic dysfunction than gated SPET-LVEF in receiver operating characteristic (ROC) analysis and identified more patients (89%) with a

  13. Making Sense of the ECG - Cases for Self-Assessment Houghton Andrew R Gray David Making Sense of the ECG - Cases for Self-Assessment 290pp Hodder Education 9780340946893 034094689X [Formula: see text].

    PubMed

    2010-10-27

    This practical, pocket-book approach to ECG interpretation accompanies the well-known text Making Sense of the ECG, by the same authors. It is also designed to be used alone to test knowledge of ECG interpretation and to make clinical decisions based on presented scenarios.

  14. Making sense of the ECG: cases for self-assessment Making Sense of the ECG: Cases for Self-Assessment Houghton Andrew and Gray David Hodder Education £18.99 290pp 9780340946893 034094689X [Formula: see text].

    PubMed

    2011-02-10

    This practical pocket-book approach to electrocardiogram (ECG) interpretation accompanies Making sense of the eCg by the same authors. it is also designed to be used alone to test knowledge of ECG interpretation and to make clinical decisions based on presented scenarios.

  15. A Novel Approach to ECG Classification Based upon Two-Layered HMMs in Body Sensor Networks

    PubMed Central

    Liang, Wei; Zhang, Yinlong; Tan, Jindong; Li, Yang

    2014-01-01

    This paper presents a novel approach to ECG signal filtering and classification. Unlike the traditional techniques which aim at collecting and processing the ECG signals with the patient being still, lying in bed in hospitals, our proposed algorithm is intentionally designed for monitoring and classifying the patient's ECG signals in the free-living environment. The patients are equipped with wearable ambulatory devices the whole day, which facilitates the real-time heart attack detection. In ECG preprocessing, an integral-coefficient-band-stop (ICBS) filter is applied, which omits time-consuming floating-point computations. In addition, two-layered Hidden Markov Models (HMMs) are applied to achieve ECG feature extraction and classification. The periodic ECG waveforms are segmented into ISO intervals, P subwave, QRS complex and T subwave respectively in the first HMM layer where expert-annotation assisted Baum-Welch algorithm is utilized in HMM modeling. Then the corresponding interval features are selected and applied to categorize the ECG into normal type or abnormal type (PVC, APC) in the second HMM layer. For verifying the effectiveness of our algorithm on abnormal signal detection, we have developed an ECG body sensor network (BSN) platform, whereby real-time ECG signals are collected, transmitted, displayed and the corresponding classification outcomes are deduced and shown on the BSN screen. PMID:24681668

  16. Multiple bio-monitoring system using visible light for electromagnetic-wave free indoor healthcare

    NASA Astrophysics Data System (ADS)

    An, Jinyoung; Pham, Ngoc Quan; Chung, Wan-Young

    2017-12-01

    In this paper, a multiple biomedical data transmission system with visible light communication (VLC) is proposed for an electromagnetic-wave-free indoor healthcare. VLC technology has emerged as an alternative solution to radio-frequency (RF) wireless systems, due to its various merits, e.g., ubiquity, power efficiency, no RF radiation, and security. With VLC, critical bio-medical signals, including electrocardiography (ECG), can be transmitted in places where RF radiation is restricted. This potential advantage of VLC could save more lives in emergency situations. A time hopping (TH) scheme is employed to transfer multiple medical-data streams in real time with a simple system design. Multiple data streams are transmitted using identical color LEDs and go into an optical detector. The received multiple data streams are demodulated and rearranged using a TH-based demodulator. The medical data is then monitored and managed to provide the necessary medical care for each patient.

  17. High-frequency ECG

    NASA Technical Reports Server (NTRS)

    Tragardh, Elin; Schlegel, Todd T.

    2006-01-01

    The standard ECG is by convention limited to 0.05-150 Hz, but higher frequencies are also present in the ECG signal. With high-resolution technology, it is possible to record and analyze these higher frequencies. The highest amplitudes of the high-frequency components are found within the QRS complex. In past years, the term "high frequency", "high fidelity", and "wideband electrocardiography" have been used by several investigators to refer to the process of recording ECGs with an extended bandwidth of up to 1000 Hz. Several investigators have tried to analyze HF-QRS with the hope that additional features seen in the QRS complex would provide information enhancing the diagnostic value of the ECG. The development of computerized ECG-recording devices that made it possible to record ECG signals with high resolution in both time and amplitude, as well as better possibilities to store and process the signals digitally, offered new methods for analysis. Different techniques to extract the HF-QRS have been described. Several bandwidths and filter types have been applied for the extraction as well as different signal-averaging techniques for noise reduction. There is no standard method for acquiring and quantifying HF-QRS. The physiological mechanisms underlying HF-QRS are still not fully understood. One theory is that HF-QRS are related to the conduction velocity and the fragmentation of the depolarization wave in the myocardium. In a three-dimensional model of the ventricles with a fractal conduction system it was shown that high numbers of splitting branches are associated with HF-QRS. In this experiment, it was also shown that the changes seen in HF-QRS in patients with myocardial ischemia might be due to the slowing of the conduction velocity in the region of ischemia. This mechanism has been tested by Watanabe et al by infusing sodium channel blockers into the left anterior descending artery in dogs. In their study, 60 unipolar ECGs were recorded from the entire ventricular surface and were signal-averaged and filtered in the 30-250 Hz frequency range. The results showed that the decrease noted in the HF-QRS correlated linearly with the local conduction delay. The results suggest that HF-QRS is a potent indicator of disturbed local conduction. An alternative theory is that HF-QRS reflect the shape of the original electrocardiographic signal. Bennhagen et al showed that root mean square (RMS) voltage values of the depolarization signal correlate poorly with the signal amplitude but highly with the first and second derivatives, i.e. the velocity and the acceleration of the signal. It has also been suggested that the autonomic nervous system affects HF-QRS. For example, sitting up causes significant changes in HF-QRS in some leads compared to the supine position [Douglas et al., 2006]. Unpublished results indicate that familial dysautonomic patients (both vagal and sympathetic degeneration) have very little Reduced Amplitude Zones (RAZ) formation . Athletic individuals, especially elite athletes, who have vagally-mediated changes on the conventional ECG (i.e. early repolarization, bradycardia) have increased RAZ formation. Further electrophysiological studies are needed, however, to better understand the underlying mechanisms of HF-QRS. Several investigators have studied HF-QRS in different cardiac conditions, including acute myocardial ischemia and myocardial infarction (MI). However, in order for clinicians to confidently use HF-QRS as an adjunct to standard ECG, more knowledge about the characteristics of HF-QRS is needed.

  18. Dry electrode bio-potential recordings.

    PubMed

    Gargiulo, Gaetano; Bifulco, Paolo; McEwan, Alistair; Nasehi Tehrani, Joubin; Calvo, Rafael A; Romano, Maria; Ruffo, Mariano; Shephard, Richard; Cesarelli, Mario; Jin, Craig; Mohamed, Armin; van Schaik, André

    2010-01-01

    As wireless bio-medical long term monitoring moves towards personal monitoring it demands very high input impedance systems capable to extend the reading of bio-signal during the daily activities offering a kind of "stress free", convenient connection, with no need for skin preparation. In particular we highlight the development and broad applications of our own circuits for wearable bio-potential sensor systems enabled by the use of an FET based amplifier circuit with sufficiently high impedance to allow the use of passive dry electrodes which overcome the significant barrier of gel based contacts. In this paper we present the ability of dry electrodes in long term monitoring of ECG, EEG and fetal ECG.

  19. Viability of a Bioelectrical Signal Acquisition System Energized by Cellphone with NFC.

    PubMed

    Kay, Marcel Seiji; Iaione, Fábio

    2015-01-01

    Currently, smartphones are used in various systems in the medical field due to the presence of various features, notably Near Field Communication (NFC). NFC utilizes communication technology and an energy supply based on electromagnetic induction. One of the most common medical tests is the electrocardiogram (ECG), through which various heart diseases can be diagnosed. The objective of this study is to evaluate the feasibility of providing power to a bioelectrical signal acquisition module using a mobile phone with NFC. After testing it was indicated that it is possible to construct a passive module to acquire ECG signals using NFC mobile phone.

  20. Design of a Biorthogonal Wavelet Transform Based R-Peak Detection and Data Compression Scheme for Implantable Cardiac Pacemaker Systems.

    PubMed

    Kumar, Ashish; Kumar, Manjeet; Komaragiri, Rama

    2018-04-19

    Bradycardia can be modulated using the cardiac pacemaker, an implantable medical device which sets and balances the patient's cardiac health. The device has been widely used to detect and monitor the patient's heart rate. The data collected hence has the highest authenticity assurance and is convenient for further electric stimulation. In the pacemaker, ECG detector is one of the most important element. The device is available in its new digital form, which is more efficient and accurate in performance with the added advantage of economical power consumption platform. In this work, a joint algorithm based on biorthogonal wavelet transform and run-length encoding (RLE) is proposed for QRS complex detection of the ECG signal and compressing the detected ECG data. Biorthogonal wavelet transform of the input ECG signal is first calculated using a modified demand based filter bank architecture which consists of a series combination of three lowpass filters with a highpass filter. Lowpass and highpass filters are realized using a linear phase structure which reduces the hardware cost of the proposed design approximately by 50%. Then, the location of the R-peak is found by comparing the denoised ECG signal with the threshold value. The proposed R-peak detector achieves the highest sensitivity and positive predictivity of 99.75 and 99.98 respectively with the MIT-BIH arrhythmia database. Also, the proposed R-peak detector achieves a comparatively low data error rate (DER) of 0.002. The use of RLE for the compression of detected ECG data achieves a higher compression ratio (CR) of 17.1. To justify the effectiveness of the proposed algorithm, the results have been compared with the existing methods, like Huffman coding/simple predictor, Huffman coding/adaptive, and slope predictor/fixed length packaging.

  1. Effect of electrocardiogram interference on cortico-cortical connectivity analysis and a possible solution.

    PubMed

    Govindan, R B; Kota, Srinivas; Al-Shargabi, Tareq; Massaro, An N; Chang, Taeun; du Plessis, Adre

    2016-09-01

    Electroencephalogram (EEG) signals are often contaminated by the electrocardiogram (ECG) interference, which affects quantitative characterization of EEG. We propose null-coherence, a frequency-based approach, to attenuate the ECG interference in EEG using simultaneously recorded ECG as a reference signal. After validating the proposed approach using numerically simulated data, we apply this approach to EEG recorded from six newborns receiving therapeutic hypothermia for neonatal encephalopathy. We compare our approach with an independent component analysis (ICA), a previously proposed approach to attenuate ECG artifacts in the EEG signal. The power spectrum and the cortico-cortical connectivity of the ECG attenuated EEG was compared against the power spectrum and the cortico-cortical connectivity of the raw EEG. The null-coherence approach attenuated the ECG contamination without leaving any residual of the ECG in the EEG. We show that the null-coherence approach performs better than ICA in attenuating the ECG contamination without enhancing cortico-cortical connectivity. Our analysis suggests that using ICA to remove ECG contamination from the EEG suffers from redistribution problems, whereas the null-coherence approach does not. We show that both the null-coherence and ICA approaches attenuate the ECG contamination. However, the EEG obtained after ICA cleaning displayed higher cortico-cortical connectivity compared with that obtained using the null-coherence approach. This suggests that null-coherence is superior to ICA in attenuating the ECG interference in EEG for cortico-cortical connectivity analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Utility of Electrocardiography (ECG)-Gated Computed Tomography (CT) for Preoperative Evaluations of Thymic Epithelial Tumors.

    PubMed

    Ozawa, Yoshiyuki; Hara, Masaki; Nakagawa, Motoo; Shibamoto, Yuta

    2016-01-01

    Preoperative evaluation of invasion to the adjacent organs is important for the thymic epithelial tumors on CT. The purpose of our study was to evaluate the utility of electrocardiography (ECG)-gated CT for assessing thymic epithelial tumors with regard to the motion artifacts produced and the preoperative diagnostic accuracy of the technique. Forty thymic epithelial tumors (36 thymomas and 4 thymic carcinomas) were examined with ECG-gated contrast-enhanced CT using a dual source scanner. The scan delay after the contrast media injection was 30 s for the non-ECG-gated CT and 100 s for the ECG-gated CT. Two radiologists blindly evaluated both the non-ECG-gated and ECG-gated CT images for motion artifacts and determined whether the tumors had invaded adjacent structures (mediastinal fat, superior vena cava, brachiocephalic veins, aorta, pulmonary artery, pericardium, or lungs) on each image. Motion artifacts were evaluated using a 3-grade scale. Surgical and pathological findings were used as a reference standard for tumor invasion. Motion artifacts were significantly reduced for all structures by ECG gating ( p =0.0089 for the lungs and p <0.0001 for the other structures). Non-ECG-gated CT and ECG-gated CT demonstrated 79% and 95% accuracy, respectively, during assessments of pericardial invasion ( p =0.03). ECG-gated CT reduced the severity of motion artifacts and might be useful for preoperative assessment whether thymic epithelial tumors have invaded adjacent structures.

  3. Utility of Electrocardiography (ECG)-Gated Computed Tomography (CT) for Preoperative Evaluations of Thymic Epithelial Tumors

    PubMed Central

    Ozawa, Yoshiyuki; Hara, Masaki; Nakagawa, Motoo; Shibamoto, Yuta

    2016-01-01

    Summary Background Preoperative evaluation of invasion to the adjacent organs is important for the thymic epithelial tumors on CT. The purpose of our study was to evaluate the utility of electrocardiography (ECG)-gated CT for assessing thymic epithelial tumors with regard to the motion artifacts produced and the preoperative diagnostic accuracy of the technique. Material/Methods Forty thymic epithelial tumors (36 thymomas and 4 thymic carcinomas) were examined with ECG-gated contrast-enhanced CT using a dual source scanner. The scan delay after the contrast media injection was 30 s for the non-ECG-gated CT and 100 s for the ECG-gated CT. Two radiologists blindly evaluated both the non-ECG-gated and ECG-gated CT images for motion artifacts and determined whether the tumors had invaded adjacent structures (mediastinal fat, superior vena cava, brachiocephalic veins, aorta, pulmonary artery, pericardium, or lungs) on each image. Motion artifacts were evaluated using a 3-grade scale. Surgical and pathological findings were used as a reference standard for tumor invasion. Results Motion artifacts were significantly reduced for all structures by ECG gating (p=0.0089 for the lungs and p<0.0001 for the other structures). Non-ECG-gated CT and ECG-gated CT demonstrated 79% and 95% accuracy, respectively, during assessments of pericardial invasion (p=0.03). Conclusions ECG-gated CT reduced the severity of motion artifacts and might be useful for preoperative assessment whether thymic epithelial tumors have invaded adjacent structures. PMID:27920842

  4. Classification of holter registers by dynamic clustering using multi-dimensional particle swarm optimization.

    PubMed

    Kiranyaz, Serkan; Ince, Turker; Pulkkinen, Jenni; Gabbouj, Moncef

    2010-01-01

    In this paper, we address dynamic clustering in high dimensional data or feature spaces as an optimization problem where multi-dimensional particle swarm optimization (MD PSO) is used to find out the true number of clusters, while fractional global best formation (FGBF) is applied to avoid local optima. Based on these techniques we then present a novel and personalized long-term ECG classification system, which addresses the problem of labeling the beats within a long-term ECG signal, known as Holter register, recorded from an individual patient. Due to the massive amount of ECG beats in a Holter register, visual inspection is quite difficult and cumbersome, if not impossible. Therefore the proposed system helps professionals to quickly and accurately diagnose any latent heart disease by examining only the representative beats (the so called master key-beats) each of which is representing a cluster of homogeneous (similar) beats. We tested the system on a benchmark database where the beats of each Holter register have been manually labeled by cardiologists. The selection of the right master key-beats is the key factor for achieving a highly accurate classification and the proposed systematic approach produced results that were consistent with the manual labels with 99.5% average accuracy, which basically shows the efficiency of the system.

  5. Effects of water-soluble natural antioxidants on photosensitized oxidation of conjugated linoleic acid in an oil-in-water emulsion system.

    PubMed

    Liu, T-T; Yang, T-S

    2008-05-01

    The effect of photosensitized oxidation of conjugated linoleic acid in an oil-in-water (o/w) emulsion system was studied. Water-soluble natural antioxidants, including apple polyphenols from apple extract, green tea extract, 4-hydroxy-2(or 5)-ethyl-5(or2)-methyl-3(2H)-furanone(HEMF), 4-hydroxy-2,5-dimethyl-3(2H)-furanone (HDMF), and ascorbic acid, were tested for antioxidant activity in this system. The green tea extract showed the highest antioxidant activity followed by ascorbic acid. Apple polyphenols did not give significant antioxidant activity. HEMF and HDMF exhibited a prooxidant effect. The antioxidant activity of tea catechins was also investigated. Of them, EGCG and ECG exhibited antioxidant activity at 50 ppm, but the antioxidant activity between them was not significantly different (P < 0.05). Comparatively, EC, EGC, and GCG showed no significant antioxidative effect at 50 ppm. When the concentration increased to 100 ppm, the antioxidant activity of ECG and EGCG significantly increased compared with that at 50 ppm, and EGCG had higher antioxidant activity than ECG. GCG also showed significant antioxidant activity at 100 ppm. EGCG exhibited the highest antioxidant activity among the tea catechins in the emulsion system at 100 ppm.

  6. A mobile device system for early warning of ECG anomalies.

    PubMed

    Szczepański, Adam; Saeed, Khalid

    2014-06-20

    With the rapid increase in computational power of mobile devices the amount of ambient intelligence-based smart environment systems has increased greatly in recent years. A proposition of such a solution is described in this paper, namely real time monitoring of an electrocardiogram (ECG) signal during everyday activities for identification of life threatening situations. The paper, being both research and review, describes previous work of the authors, current state of the art in the context of the authors' work and the proposed aforementioned system. Although parts of the solution were described in earlier publications of the authors, the whole concept is presented completely for the first time along with the prototype implementation on mobile device-a Windows 8 tablet with Modern UI. The system has three main purposes. The first goal is the detection of sudden rapid cardiac malfunctions and informing the people in the patient's surroundings, family and friends and the nearest emergency station about the deteriorating health of the monitored person. The second goal is a monitoring of ECG signals under non-clinical conditions to detect anomalies that are typically not found during diagnostic tests. The third goal is to register and analyze repeatable, long-term disturbances in the regular signal and finding their patterns.

  7. Explicitly-correlated non-born-oppenheimer calculations of the HD molecule in a strong magnetic field

    NASA Astrophysics Data System (ADS)

    Adamowicz, Ludwik; Stanke, Monika; Tellgren, Erik; Helgaker, Trygve

    2017-08-01

    Explicitly correlated all-particle Gaussian functions with shifted centers (ECGs) are implemented within the earlier proposed effective variational non-Born-Oppenheimer method for calculating bound states of molecular systems in magnetic field (Adamowicz et al., 2015). The Hamiltonian used in the calculations is obtained by subtracting the operator representing the kinetic energy of the center-of-mass motion from the total laboratory-frame Hamiltonian. Test ECG calculations are performed for the HD molecule.

  8. [The relationship of ECG and pregnancy outcome of older pregnant woman in late pregnancy].

    PubMed

    Zhao, Xiao-Qin; Wang, Chun-Guang; Song, Yu-Xia; Jiao, Hong

    2014-01-01

    To observe the changes of electrocardiogram (ECG) and pregnancy outcome of the late pregnancy women. Late pregnancy women were divided into two groups by age: over 35 group and under 35 group. The incidence of abnormal electrocardiogram was recorded when the patients were subjected to routine ECG examination. Then the pregnancy, delivery outcome and if there's low birth weight newborn were recorded later. The incidence of abnormal ECG in over 35 group was significantly higher than that in under 35 group (P < 0.05). And the incidence of ST segment changes, arrhythmia in the group of former was higher than that in the group of latter (P < 0.05). Among the different type of arrhythmia, the incidence of sinus bradycardia and ventricular premature beat in the group of former were higher than those in the group of latter (P < 0.05). But the incidence of sinus tachycardia in the former group was obviously lower than that in the latter group (P < 0.05). The incidence of pregnancy loss in over 35 with abnormal ECG group was significantly higher than that in under 35 with normal or abnormal ECG groups (P < 0.05). The incidence of premature birth in over 35 with abnormal ECG group was significantly higher than that in over 35 with normal ECG group (P < 0.05). The incidence of low body weight in over 35 with abnormal ECG group was significantly higher than that in under 35 with normal ECG group (P < 0.05). The late pregnancy women with the age of over 35 are more likely to have ECG abnormalities, such as arrhythmia, myocardial ischemia and so on. The older pregnant women with abnormal ECG easily suffer from pregnancy losing, premature birth and having a low birth weight baby.

  9. Differences in alarm events between disposable and reusable electrocardiography lead wires.

    PubMed

    Albert, Nancy M; Murray, Terri; Bena, James F; Slifcak, Ellen; Roach, Joel D; Spence, Jackie; Burkle, Alicia

    2015-01-01

    Disposable electrocardiographic lead wires (ECG-LWs) may not be as durable as reusable ones. To examine differences in alarm events between disposable and reusable ECG-LWs. Two cardiac telemetry units were randomized to reusable ECG-LWs, and 2 units alternated between disposable and reusable ECG-LWs for 4 months. A remote monitoring team, blinded to ECG-LW type, assessed frequency and type of alarm events by using total counts and rates per 100 patient days. Event rates were compared by using generalized linear mixed-effect models for differences and noninferiority between wire types. In 1611 patients and 9385.5 patient days of ECG monitoring, patient characteristics were similar between groups. Rates of alarms for no telemetry, leads fail, or leads off were lower in disposable ECG-LWs (adjusted relative risk [95% CI], 0.71 [0.53-0.96]; noninferiority P < .001; superiority P = .03) and monitoring (artifact) alarms were significantly noninferior (adjusted relative risk [95% CI]: 0.88, [0.62-1.24], P = .02; superiority P = .44). No between-group differences existed in false or true crisis alarms. Disposable ECG-LWs were noninferior to reusable ECG-LWs for all false-alarm events (N [rate per 100 patient days], disposable 2029 [79.1] vs reusable 6673 [97.9]; adjusted relative risk [95% CI]: 0.81 [0.63-1.06], P = .002; superiority P = .12.) Disposable ECG-LWs with patented push-button design had superior performance in reducing alarms created by no telemetry, leads fail, or leads off and significant noninferiority in all false-alarm rates compared with reusable ECG-LWs. Fewer ECG alarms may save nurses time, decrease alarm fatigue, and improve patient safety. ©2015 American Association of Critical-Care Nurses.

  10. The effect of sport on computerized electrocardiogram measurements in college athletes.

    PubMed

    Gademan, Maaike G J; Uberoi, Abhimanyu; Le, Vy-Van; Mandic, Sandra; van Oort, Eddy R; Myers, Jonathan; Froelicher, Victor F

    2012-02-01

    Broad criteria for abnormal electrocardiogram (ECG) findings, requiring additional testing, have been recommended for preparticipation exams (PPE) of athletes. As these criteria have not considered the sport in which athletes participate, we examined the effect of sports on the computerized ECG measurements obtained in college athletes. During the Stanford 2007 PPE, computerized 12-lead ECGs (Schiller AG) were obtained in 641 athletes (350 male/291 female, age 19.5 ± 2 years). Athletes were engaged in 22 different sports and were grouped into 16 categories: baseball/softball, basketball, crew, crosscountry, fencing, field events, football linemen, football other positions, golf, gymnastics, racquet sports, sailing, track/field, volleyball, water sports, and wrestling. The analysis focused on ECG leads V2, aVF and V5 which provide a three-dimensional representation of the heart's electrical activity. As marked ECG differences exist between males and females, the data are presented by gender. In males, ANOVA analysis yielded significant ECG differences between sports for heart rate, QRS duration, QTc, J-amplitude in V2 and V5, spatial vector length (SVL) of the P wave, SVL R wave, and SVL T wave, and RS(sum) (p < 0.05). In females ECG differences between sports were found for heart rate, QRS duration, QRS axis and SVL T wave (p < 0.05). Poor correlations were found between body dimensions and ECG measurements (r < 0.50). Significant ECG changes exist between college athletes participating in different sports, and these differences were more apparent in males than females. Therefore, sport-specific ECG criteria for abnormal ECG findings should be developed to obtain a more useful approach to ECG screening in athletes.

  11. Textile Concentric Ring Electrodes for ECG Recording Based on Screen-Printing Technology

    PubMed Central

    Ye-Lin, Yiyao; Garcia-Casado, Javier

    2018-01-01

    Among many of the electrode designs used in electrocardiography (ECG), concentric ring electrodes (CREs) are one of the most promising due to their enhanced spatial resolution. Their development has undergone a great push due to their use in recent years; however, they are not yet widely used in clinical practice. CRE implementation in textiles will lead to a low cost, flexible, comfortable, and robust electrode capable of detecting high spatial resolution ECG signals. A textile CRE set has been designed and developed using screen-printing technology. This is a mature technology in the textile industry and, therefore, does not require heavy investments. Inks employed as conductive elements have been silver and a conducting polymer (poly (3,4-ethylenedioxythiophene) polystyrene sulfonate; PEDOT:PSS). Conducting polymers have biocompatibility advantages, they can be used with flexible substrates, and they are available for several printing technologies. CREs implemented with both inks have been compared by analyzing their electric features and their performance in detecting ECG signals. The results reveal that silver CREs present a higher average thickness and slightly lower skin-electrode impedance than PEDOT:PSS CREs. As for ECG recordings with subjects at rest, both CREs allowed the uptake of bipolar concentric ECG signals (BC-ECG) with signal-to-noise ratios similar to that of conventional ECG recordings. Regarding the saturation and alterations of ECGs captured with textile CREs caused by intentional subject movements, silver CREs presented a more stable response (fewer saturations and alterations) than those of PEDOT:PSS. Moreover, BC-ECG signals provided higher spatial resolution compared to conventional ECG. This improved spatial resolution was manifested in the identification of P1 and P2 waves of atrial activity in most of the BC-ECG signals. It can be concluded that textile silver CREs are more suitable than those of PEDOT:PSS for obtaining BC-ECG records. These developed textile electrodes bring the use of CREs closer to the clinical environment. PMID:29361722

  12. Textile Concentric Ring Electrodes for ECG Recording Based on Screen-Printing Technology.

    PubMed

    Lidón-Roger, José Vicente; Prats-Boluda, Gema; Ye-Lin, Yiyao; Garcia-Casado, Javier; Garcia-Breijo, Eduardo

    2018-01-21

    Among many of the electrode designs used in electrocardiography (ECG), concentric ring electrodes (CREs) are one of the most promising due to their enhanced spatial resolution. Their development has undergone a great push due to their use in recent years; however, they are not yet widely used in clinical practice. CRE implementation in textiles will lead to a low cost, flexible, comfortable, and robust electrode capable of detecting high spatial resolution ECG signals. A textile CRE set has been designed and developed using screen-printing technology. This is a mature technology in the textile industry and, therefore, does not require heavy investments. Inks employed as conductive elements have been silver and a conducting polymer (poly (3,4-ethylenedioxythiophene) polystyrene sulfonate; PEDOT:PSS). Conducting polymers have biocompatibility advantages, they can be used with flexible substrates, and they are available for several printing technologies. CREs implemented with both inks have been compared by analyzing their electric features and their performance in detecting ECG signals. The results reveal that silver CREs present a higher average thickness and slightly lower skin-electrode impedance than PEDOT:PSS CREs. As for ECG recordings with subjects at rest, both CREs allowed the uptake of bipolar concentric ECG signals (BC-ECG) with signal-to-noise ratios similar to that of conventional ECG recordings. Regarding the saturation and alterations of ECGs captured with textile CREs caused by intentional subject movements, silver CREs presented a more stable response (fewer saturations and alterations) than those of PEDOT:PSS. Moreover, BC-ECG signals provided higher spatial resolution compared to conventional ECG. This improved spatial resolution was manifested in the identification of P1 and P2 waves of atrial activity in most of the BC-ECG signals. It can be concluded that textile silver CREs are more suitable than those of PEDOT:PSS for obtaining BC-ECG records. These developed textile electrodes bring the use of CREs closer to the clinical environment.

  13. The intracavitary ECG method for positioning the tip of central venous access devices in pediatric patients: results of an Italian multicenter study.

    PubMed

    Rossetti, Francesca; Pittiruti, Mauro; Lamperti, Massimo; Graziano, Ugo; Celentano, Davide; Capozzoli, Giuseppe

    2015-01-01

    The Italian Group for Venous Access Devices (GAVeCeLT) has carried out a multicenter study investigating the safety and accuracy of intracavitary electrocardiography (IC-ECG) in pediatric patients. We enrolled 309 patients (age 1 month-18 years) candidate to different central venous access devices (VAD) - 56 peripherally inserted central catheters (PICC), 178 short term centrally inserted central catheters (CICC), 65 long term VADs, 10 VADs for dialysis - in five Italian Hospitals. Three age groups were considered: A (<4 years, n = 157), B (4-11 years, n = 119), and C (12-18 years, n = 31). IC-ECG was applicable in 307 cases. The increase of the P wave on IC-ECG was detected in all cases but two. The tip of the catheter was positioned at the cavo-atrial junction (CAJ) (i.e., at the maximal height of the P wave on IC-ECG) and the position was checked during the procedure by fluoroscopy or chest x-ray, considering the CAJ at 1-2 cm (group A), 1.5-3 cm (group B), or 2-4 cm (group C) below the carina. There were no complications related to IC-ECG. The overall match between IC-ECG and x-ray was 95.8% (96.2% in group A, 95% in group B, and 96.8% in group C). In 95 cases, the IC-ECG was performed with a dedicated ECG monitor, specifically designed for IC-ECG (Nautilus, Romedex): in this group, the match between IC-ECG and x-ray was 98.8%. We conclude that the IC-ECG method is safe and accurate in the pediatric patients. The applicability of the method is 99.4% and its feasibility is 99.4%. The accuracy is 95.8% and even higher (98.8%) when using a dedicated ECG monitor.

  14. A novel low-complexity digital filter design for wearable ECG devices

    PubMed Central

    Mehrnia, Alireza

    2017-01-01

    Wearable and implantable Electrocardiograph (ECG) devices are becoming prevailing tools for continuous real-time personal health monitoring. The ECG signal can be contaminated by various types of noise and artifacts (e.g., powerline interference, baseline wandering) that must be removed or suppressed for accurate ECG signal processing. Limited device size, power consumption and cost are critical issues that need to be carefully considered when designing any portable health monitoring device, including a battery-powered ECG device. This work presents a novel low-complexity noise suppression reconfigurable finite impulse response (FIR) filter structure for wearable ECG and heart monitoring devices. The design relies on a recently introduced optimally-factored FIR filter method. The new filter structure and several of its useful features are presented in detail. We also studied the hardware complexity of the proposed structure and compared it with the state-of-the-art. The results showed that the new ECG filter has a lower hardware complexity relative to the state-of-the-art ECG filters. PMID:28384272

  15. A cloud computing based 12-lead ECG telemedicine service

    PubMed Central

    2012-01-01

    Background Due to the great variability of 12-lead ECG instruments and medical specialists’ interpretation skills, it remains a challenge to deliver rapid and accurate 12-lead ECG reports with senior cardiologists’ decision making support in emergency telecardiology. Methods We create a new cloud and pervasive computing based 12-lead Electrocardiography (ECG) service to realize ubiquitous 12-lead ECG tele-diagnosis. Results This developed service enables ECG to be transmitted and interpreted via mobile phones. That is, tele-consultation can take place while the patient is on the ambulance, between the onsite clinicians and the off-site senior cardiologists, or among hospitals. Most importantly, this developed service is convenient, efficient, and inexpensive. Conclusions This cloud computing based ECG tele-consultation service expands the traditional 12-lead ECG applications onto the collaboration of clinicians at different locations or among hospitals. In short, this service can greatly improve medical service quality and efficiency, especially for patients in rural areas. This service has been evaluated and proved to be useful by cardiologists in Taiwan. PMID:22838382

  16. Designing ECG-based physical unclonable function for security of wearable devices.

    PubMed

    Shihui Yin; Chisung Bae; Sang Joon Kim; Jae-Sun Seo

    2017-07-01

    As a plethora of wearable devices are being introduced, significant concerns exist on the privacy and security of personal data stored on these devices. Expanding on recent works of using electrocardiogram (ECG) as a modality for biometric authentication, in this work, we investigate the possibility of using personal ECG signals as the individually unique source for physical unclonable function (PUF), which eventually can be used as the key for encryption and decryption engines. We present new signal processing and machine learning algorithms that learn and extract maximally different ECG features for different individuals and minimally different ECG features for the same individual over time. Experimental results with a large 741-subject in-house ECG database show that the distributions of the intra-subject (same person) Hamming distance of extracted ECG features and the inter-subject Hamming distance have minimal overlap. 256-b random numbers generated from the ECG features of 648 (out of 741) subjects pass the NIST randomness tests.

  17. Eyewitness to history: Landmarks in the development of computerized electrocardiography.

    PubMed

    Rautaharju, Pentti M

    2016-01-01

    The use of digital computers for ECG processing was pioneered in the early 1960s by two immigrants to the US, Hubert Pipberger, who initiated a collaborative VA project to collect an ECG-independent Frank lead data base, and Cesar Caceres at NIH who selected for his ECAN program standard 12-lead ECGs processed as single leads. Ray Bonner in the early 1970s placed his IBM 5880 program in a cart to print ECGs with interpretation, and computer-ECG programs were developed by Telemed, Marquette, HP-Philips and Mortara. The "Common Standards for quantitative Electrocardiography (CSE)" directed by Jos Willems evaluated nine ECG programs and eight cardiologists in clinically-defined categories. The total accuracy by a representative "average" cardiologist (75.5%) was 5.8% higher than that of the average program (69.7, p<0.001). Future comparisons of computer-based and expert reader performance are likely to show evolving results with continuing improvement of computer-ECG algorithms and changing expertise of ECG interpreters. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. A cloud computing based 12-lead ECG telemedicine service.

    PubMed

    Hsieh, Jui-Chien; Hsu, Meng-Wei

    2012-07-28

    Due to the great variability of 12-lead ECG instruments and medical specialists' interpretation skills, it remains a challenge to deliver rapid and accurate 12-lead ECG reports with senior cardiologists' decision making support in emergency telecardiology. We create a new cloud and pervasive computing based 12-lead Electrocardiography (ECG) service to realize ubiquitous 12-lead ECG tele-diagnosis. This developed service enables ECG to be transmitted and interpreted via mobile phones. That is, tele-consultation can take place while the patient is on the ambulance, between the onsite clinicians and the off-site senior cardiologists, or among hospitals. Most importantly, this developed service is convenient, efficient, and inexpensive. This cloud computing based ECG tele-consultation service expands the traditional 12-lead ECG applications onto the collaboration of clinicians at different locations or among hospitals. In short, this service can greatly improve medical service quality and efficiency, especially for patients in rural areas. This service has been evaluated and proved to be useful by cardiologists in Taiwan.

  19. A novel low-complexity digital filter design for wearable ECG devices.

    PubMed

    Asgari, Shadnaz; Mehrnia, Alireza

    2017-01-01

    Wearable and implantable Electrocardiograph (ECG) devices are becoming prevailing tools for continuous real-time personal health monitoring. The ECG signal can be contaminated by various types of noise and artifacts (e.g., powerline interference, baseline wandering) that must be removed or suppressed for accurate ECG signal processing. Limited device size, power consumption and cost are critical issues that need to be carefully considered when designing any portable health monitoring device, including a battery-powered ECG device. This work presents a novel low-complexity noise suppression reconfigurable finite impulse response (FIR) filter structure for wearable ECG and heart monitoring devices. The design relies on a recently introduced optimally-factored FIR filter method. The new filter structure and several of its useful features are presented in detail. We also studied the hardware complexity of the proposed structure and compared it with the state-of-the-art. The results showed that the new ECG filter has a lower hardware complexity relative to the state-of-the-art ECG filters.

  20. Subtle alternating electrocardiographic morphology as an indicator of decreased cardiac electrical stability

    NASA Technical Reports Server (NTRS)

    Smith, J. M.; Blue, B.; Clancy, E.; Valeri, C. R.; Cohen, R. J.

    1985-01-01

    Observations from finite-element computer models, together with analytic developments based on percolation theory have suggested that subtle fluctuations of ECG morphology might serve as an indicator diminished cardiac electrical stability. With fixed-rate atrial pacing in canines, we have previously observed a pattern of alternation in T wave energy which correlated with cardiac electrical stability. We report here on a series of 20 canine experiments in which cardiac electrical stability (measured via Ventricular Fibrillation Threshold determination) was compared to a non-degenerate, multidimensional measurement of the degree of alternating activity present in the ECG complex morphology. The decrease in cardiac electrical stability brought on by both coronary artery occlusion and systemic hypothermia was consistently accompanied by subtle alternation in ECG morphology, with the absolute degree of alternating activity being significantly (negatively) correlated with cardiac electrical stability.

  1. Ischemic ECG abnormalities are associated with an increased risk for death among subjects with COPD, also among those without known heart disease.

    PubMed

    Nilsson, Ulf; Blomberg, Anders; Johansson, Bengt; Backman, Helena; Eriksson, Berne; Lindberg, Anne

    2017-01-01

    An abstract, including parts of the results, has been presented at an oral session at the European Respiratory Society International Conference, London, UK, September 2016. Cardiovascular comorbidity contributes to increased mortality among subjects with COPD. However, the prognostic value of ECG abnormalities in COPD has rarely been studied in population-based surveys. To assess the impact of ischemic ECG abnormalities (I-ECG) on mortality among individuals with COPD, compared to subjects with normal lung function (NLF), in a population-based study. During 2002-2004, all subjects with FEV 1 /VC <0.70 (COPD, n=993) were identified from population-based cohorts, together with age- and sex-matched referents without COPD. Re-examination in 2005 included interview, spirometry, and 12-lead ECG in COPD (n=635) and referents [n=991, whereof 786 had NLF]. All ECGs were Minnesota-coded. Mortality data were collected until December 31, 2010. I-ECG was equally common in COPD and NLF. The 5-year cumulative mortality was higher among subjects with I-ECG in both groups (29.6% vs 10.6%, P <0.001 and 17.1% vs 6.6%, P <0.001). COPD, but not NLF, with I-ECG had increased risk for death assessed as the mortality risk ratio [95% confidence interval (CI)] when compared with NLF without I-ECG, 2.36 (1.45-3.85) and 1.65 (0.94-2.90) when adjusted for common confounders. When analyzed separately among the COPD cohort, the increased risk for death associated with I-ECG persisted after adjustment for FEV 1 % predicted, 1.89 (1.20-2.99). A majority of those with I-ECG had no previously reported heart disease (74.2% in NLF and 67.3% in COPD) and the pattern was similar among them. I-ECG was associated with an increased risk for death in COPD, independent of common confounders and disease severity. I-ECG was of prognostic value also among those without previously known heart disease.

  2. GPS and GPRS Based Telemonitoring System for Emergency Patient Transportation

    PubMed Central

    Satyanarayana, K.; Sarma, A. D.; Sravan, J.; Malini, M.; Venkateswarlu, G.

    2013-01-01

    Telemonitoring during the golden hour of patient transportation helps to improve medical care. Presently there are different physiological data acquisition and transmission systems using cellular network and radio communication links. Location monitoring systems and video transmission systems are also commercially available. The emergency patient transportation systems uniquely require transmission of data pertaining to the patient, vehicle, time of the call, physiological signals (like ECG, blood pressure, a body temperature, and blood oxygen saturation), location information, a snap shot of the patient, and voice. These requirements are presently met by using separate communication systems for voice, physiological data, and location that result in a lot of inconvenience to the technicians, maintenance related issues, in addition to being expensive. This paper presents design, development, and implementation of such a telemonitoring system for emergency patient transportation employing ARM 9 processor module. This system is found to be very useful for the emergency patient transportation being undertaken by organizations like the Emergency Management Research Institute (EMRI). PMID:27019844

  3. The history, hotspots, and trends of electrocardiogram.

    PubMed

    Yang, Xiang-Lin; Liu, Guo-Zhen; Tong, Yun-Hai; Yan, Hong; Xu, Zhi; Chen, Qi; Liu, Xiang; Zhang, Hong-Hao; Wang, Hong-Bo; Tan, Shao-Hua

    2015-07-01

    The electrocardiogram (ECG) has broad applications in clinical diagnosis and prognosis of cardiovascular disease. Many researchers have contributed to its progressive development. To commemorate those pioneers, and to better study and promote the use of ECG, we reviewed and present here a systematic introduction about the history, hotspots, and trends of ECG. In the historical part, information including the invention, improvement, and extensive applications of ECG, such as in long QT syndrome (LQTS), angina, and myocardial infarction (MI), are chronologically presented. New technologies and applications from the 1990s are also introduced. In the second part, we use the bibliometric analysis method to analyze the hotspots in the field of ECG-related research. By using total citations and year-specific total citations as our main criteria, four key hotspots in ECG-related research were identified from 11 articles, including atrial fibrillation, LQTS, angina and MI, and heart rate variability. Recent studies in those four areas are also reported. In the final part, we discuss the future trends concerning ECG-related research. The authors believe that improvement of the ECG instrumentation, big data mining for ECG, and the accuracy of diagnosis and application will be areas of continuous concern.

  4. Case report: an electrocardiogram of spontaneous pneumothorax mimicking arm lead reversal.

    PubMed

    Wieters, J Scott; Carlin, Joseph P; Morris, Andrew

    2014-05-01

    There are several previously documented findings for electrocardiograms (ECGs) of spontaneous pneumothorax. These findings include axis deviation, T-wave inversion, and right bundle branch block. When an ECG has the arm leads incorrectly placed, the ECG will display right axis deviation and inversion of the P waves in lead I. There have been no previously published ECGs of spontaneous pneumothorax that have shown the same findings as reversal of the limb leads of an ECG. A possible finding of spontaneous pneumothorax is an identical finding to that of an ECG that has been flagged for limb lead reversal. A patient presented in the emergency setting with acute chest pain and shortness of breath caused by a tension pneumothorax. An ECG was administered; findings indicated reversal of the arm leads (right axis deviation and inverted P waves in lead I), but there was no actual limb lead reversal present. ECG findings resolved upon resolution of the pneumothorax. If a patient presents with chest pain and shortness of breath, and the patient's ECG is flagged for limb lead reversal despite being set up correctly, the physician should raise clinical suspicion for a possible spontaneous pneumothorax. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. The history, hotspots, and trends of electrocardiogram

    PubMed Central

    Yang, Xiang-Lin; Liu, Guo-Zhen; Tong, Yun-Hai; Yan, Hong; Xu, Zhi; Chen, Qi; Liu, Xiang; Zhang, Hong-Hao; Wang, Hong-Bo; Tan, Shao-Hua

    2015-01-01

    The electrocardiogram (ECG) has broad applications in clinical diagnosis and prognosis of cardiovascular disease. Many researchers have contributed to its progressive development. To commemorate those pioneers, and to better study and promote the use of ECG, we reviewed and present here a systematic introduction about the history, hotspots, and trends of ECG. In the historical part, information including the invention, improvement, and extensive applications of ECG, such as in long QT syndrome (LQTS), angina, and myocardial infarction (MI), are chronologically presented. New technologies and applications from the 1990s are also introduced. In the second part, we use the bibliometric analysis method to analyze the hotspots in the field of ECG-related research. By using total citations and year-specific total citations as our main criteria, four key hotspots in ECG-related research were identified from 11 articles, including atrial fibrillation, LQTS, angina and MI, and heart rate variability. Recent studies in those four areas are also reported. In the final part, we discuss the future trends concerning ECG-related research. The authors believe that improvement of the ECG instrumentation, big data mining for ECG, and the accuracy of diagnosis and application will be areas of continuous concern. PMID:26345622

  6. Exploring the Relationship Between Eye Movements and Electrocardiogram Interpretation Accuracy

    NASA Astrophysics Data System (ADS)

    Davies, Alan; Brown, Gavin; Vigo, Markel; Harper, Simon; Horseman, Laura; Splendiani, Bruno; Hill, Elspeth; Jay, Caroline

    2016-12-01

    Interpretation of electrocardiograms (ECGs) is a complex task involving visual inspection. This paper aims to improve understanding of how practitioners perceive ECGs, and determine whether visual behaviour can indicate differences in interpretation accuracy. A group of healthcare practitioners (n = 31) who interpret ECGs as part of their clinical role were shown 11 commonly encountered ECGs on a computer screen. The participants’ eye movement data were recorded as they viewed the ECGs and attempted interpretation. The Jensen-Shannon distance was computed for the distance between two Markov chains, constructed from the transition matrices (visual shifts from and to ECG leads) of the correct and incorrect interpretation groups for each ECG. A permutation test was then used to compare this distance against 10,000 randomly shuffled groups made up of the same participants. The results demonstrated a statistically significant (α  0.05) result in 5 of the 11 stimuli demonstrating that the gaze shift between the ECG leads is different between the groups making correct and incorrect interpretations and therefore a factor in interpretation accuracy. The results shed further light on the relationship between visual behaviour and ECG interpretation accuracy, providing information that can be used to improve both human and automated interpretation approaches.

  7. Anatomic distribution of culprit lesions in patients with non-ST-segment elevation myocardial infarction and normal ECG.

    PubMed

    Moustafa, Abdelmoniem; Abi-Saleh, Bernard; El-Baba, Mohammad; Hamoui, Omar; AlJaroudi, Wael

    2016-02-01

    In patients presenting with non-ST-elevation myocardial infarction (NSTEMI), left anterior descending (LAD) coronary artery and three-vessel disease are the most commonly encountered culprit lesions in the presence of ST depression, while one third of patients with left circumflex (LCX) artery related infarction have normal ECG. We sought to determine the predictors of presence of culprit lesion in NSTEMI patients based on ECG, echocardiographic, and clinical characteristics. Patients admitted to the coronary care unit with the diagnosis of NSTEMI between June 2012 and December 2013 were retrospectively identified. Admission ECG was interpreted by an electrophysiologist that was blinded to the result of the coronary angiogram. Patients were dichotomized into either normal or abnormal ECG group. The primary endpoint was presence of culprit lesion. Secondary endpoints included length of stay, re-hospitalization within 60 days, and in-hospital mortality. A total of 118 patients that were identified; 47 with normal and 71 with abnormal ECG. At least one culprit lesion was identified in 101 patients (86%), and significantly more among those with abnormal ECG (91.5% vs. 76.6%, P=0.041).The LAD was the most frequently detected culprit lesion in both groups. There was a higher incidence of two and three-vessel disease in the abnormal ECG group (P=0.041).On the other hand, there was a trend of higher LCX involvement (25% vs. 13.8%, P=0.18) and more normal coronary arteries in the normal ECG group (23.4% vs. 8.5%, P=0.041). On multivariate analysis, prior history of coronary artery disease (CAD) [odds ratio (OR) 6.4 (0.8-52)], male gender [OR 5.0 (1.5-17)], and abnormal admission ECG [OR 3.6 (1.12-12)], were independent predictors of a culprit lesion. There was no difference in secondary endpoints between those with normal and abnormal ECG. Among patients presenting with NSTEMI, prior history of CAD, male gender and abnormal admission ECG were independent predictors of a culprit lesion. An abnormal ECG was significantly associated with two and three-vessel disease, while normal ECG was more associated with LCX involvement or normal angiogram. Admission ECG did not impact secondary outcomes.

  8. [Cardiac comorbidity in patients with chronic obstructive pulmonary disease: diagnosis and economics].

    PubMed

    Akramova, É G; Khamitova, R Ia

    2014-01-01

    To provide a clinical and economic rationale for the comprehensive examination of patients with chronic obstructive pulmonary disease (COPD), by using functional and ultrasound methods for the early detection of cardiac comorbidity. Three hundred and sixteen patients (33 with COPD, 44 with COPD + hypertension, 73 with COPD + coronary heart disease (CHD), 36 with hypertension, 50 with CHD, 19 with asthma, and 28 with asthma + hypertension) and 33 apparently healthy individuals were examined using 611 indicators obtained directly or by calculation during echocardiography, carotid artery duplex scanning, and 24-hour electrocardiographic (ECG) and blood pressure (BP) monitoring. Cardiovascular diseases develop in patients with COPD in its early stages. In cardiac comorbidity, the length of hospital stay increases by 1-1.5 days in patients with COPD; the number of people admitted to hospital more than once every 3 years rises from 14 to 28%; the cost of a pharmacotherapy cycle is 1.35- and 2.95-fold higher when COPD is concurrent with hypertension and CHD, respectively. In addition to ECG and spirometry, the management standard for patients with COPD should include echocardiography, 24-hour ECG and BP monitoring, and, according to their results, carotid artery duplex scanning.

  9. Experimental evaluations of wearable ECG monitor.

    PubMed

    Ha, Kiryong; Kim, Youngsung; Jung, Junyoung; Lee, Jeunwoo

    2008-01-01

    Healthcare industry is changing with ubiquitous computing environment and wearable ECG measurement is one of the most popular approaches in this healthcare industry. Reliability and performance of healthcare device is fundamental issue for widespread adoptions, and interdisciplinary perspectives of wearable ECG monitor make this more difficult. In this paper, we propose evaluation criteria considering characteristic of both ECG measurement and ubiquitous computing. With our wearable ECG monitors, various levels of experimental analysis are performed based on evaluation strategy.

  10. Electrocardiographic interpretation skills of cardiology residents: are they competent?

    PubMed

    Sibbald, Matthew; Davies, Edward G; Dorian, Paul; Yu, Eric H C

    2014-12-01

    Achieving competency at electrocardiogram (ECG) interpretation among cardiology subspecialty residents has traditionally focused on interpreting a target number of ECGs during training. However, there is little evidence to support this approach. Further, there are no data documenting the competency of ECG interpretation skills among cardiology residents, who become de facto the gold standard in their practice communities. We tested 29 Cardiology residents from all 3 years in a large training program using a set of 20 ECGs collected from a community cardiology practice over a 1-month period. Residents interpreted half of the ECGs using a standard analytic framework, and half using their own approach. Residents were scored on the number of correct and incorrect diagnoses listed. Overall diagnostic accuracy was 58%. Of 6 potentially life-threatening diagnoses, residents missed 36% (123 of 348) including hyperkalemia (81%), long QT (52%), complete heart block (35%), and ventricular tachycardia (19%). Residents provided additional inappropriate diagnoses on 238 ECGs (41%). Diagnostic accuracy was similar between ECGs interpreted using an analytic framework vs ECGs interpreted without an analytic framework (59% vs 58%; F(1,1333) = 0.26; P = 0.61). Cardiology resident proficiency at ECG interpretation is suboptimal. Despite the use of an analytic framework, there remain significant deficiencies in ECG interpretation among Cardiology residents. A more systematic method of addressing these important learning gaps is urgently needed. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  11. A survey of paediatricians on the use of electrocardiogram for pre-participation sports screening.

    PubMed

    Patel, Angira; Webster, Gregory; Ward, Kendra; Lantos, John

    2017-07-01

    Aim The aim of the present study was to determine general paediatrician knowledge, practices, and attitudes towards electrocardiogram (ECG) screening in school athletes during pre-participation screening exam (PPSE). Paediatricians affiliated with a tertiary children's hospital completed a survey about ECGs for PPSE. In total, 205/498 (41%) responded; 92% of the paediatricians did not include an ECG as part of PPSE; 56% were aware of a case in which a student athlete in their own community had died of sudden unexplained death; 4% had an athlete in their practice die. Only 16% of paediatricians perform all 12 American Heart Association recommended elements of the PPSE. If any of these screening elements are abnormal, 69% obtain an ECG, 36% an echocardiogram, and 30% restrict patients from sports activity; 73% of them refer the patient to a cardiologist. Most of the general paediatricians surveyed did not currently perform ECGs for PPSE. In addition, there was a low rate of adherence to performing the 12 screening elements recommended by the American Heart Association. They have trouble obtaining timely, accurate ECG interpretations, worry about potential unnecessary exercise restrictions, and cost-effectiveness. The practical hurdles to ECG implementation emphasise the need for a fresh look at PPSE, and not just ECG screening. Improvements in ECG performance/interpretation would be necessary for ECGs to be a useful part of PPSE.

  12. Individual Biometric Identification Using Multi-Cycle Electrocardiographic Waveform Patterns.

    PubMed

    Lee, Wonki; Kim, Seulgee; Kim, Daeeun

    2018-03-28

    The electrocardiogram (ECG) waveform conveys information regarding the electrical property of the heart. The patterns vary depending on the individual heart characteristics. ECG features can be potentially used for biometric recognition. This study presents a new method using the entire ECG waveform pattern for matching and demonstrates that the approach can potentially be employed for individual biometric identification. Multi-cycle ECG signals were assessed using an ECG measuring circuit, and three electrodes can be patched on the wrists or fingers for considering various measurements. For biometric identification, our-fold cross validation was used in the experiments for assessing how the results of a statistical analysis will generalize to an independent data set. Four different pattern matching algorithms, i.e., cosine similarity, cross correlation, city block distance, and Euclidean distances, were tested to compare the individual identification performances with a single channel of ECG signal (3-wire ECG). To evaluate the pattern matching for biometric identification, the ECG recordings for each subject were partitioned into training and test set. The suggested method obtained a maximum performance of 89.9% accuracy with two heartbeats of ECG signals measured on the wrist and 93.3% accuracy with three heartbeats for 55 subjects. The performance rate with ECG signals measured on the fingers improved up to 99.3% with two heartbeats and 100% with three heartbeats of signals for 20 subjects.

  13. International recommendations for electrocardiographic interpretation in athletes.

    PubMed

    Sharma, Sanjay; Drezner, Jonathan A; Baggish, Aaron; Papadakis, Michael; Wilson, Mathew G; Prutkin, Jordan M; La Gerche, Andre; Ackerman, Michael J; Borjesson, Mats; Salerno, Jack C; Asif, Irfan M; Owens, David S; Chung, Eugene H; Emery, Michael S; Froelicher, Victor F; Heidbuchel, Hein; Adamuz, Carmen; Asplund, Chad A; Cohen, Gordon; Harmon, Kimberly G; Marek, Joseph C; Molossi, Silvana; Niebauer, Josef; Pelto, Hank F; Perez, Marco V; Riding, Nathan R; Saarel, Tess; Schmied, Christian M; Shipon, David M; Stein, Ricardo; Vetter, Victoria L; Pelliccia, Antonio; Corrado, Domenico

    2018-04-21

    Sudden cardiac death (SCD) is the leading cause of mortality in athletes during sport. A variety of mostly hereditary, structural, or electrical cardiac disorders are associated with SCD in young athletes, the majority of which can be identified or suggested by abnormalities on a resting 12-lead electrocardiogram (ECG). Whether used for diagnostic or screening purposes, physicians responsible for the cardiovascular care of athletes should be knowledgeable and competent in ECG interpretation in athletes. However, in most countries a shortage of physician expertise limits wider application of the ECG in the care of the athlete. A critical need exists for physician education in modern ECG interpretation that distinguishes normal physiological adaptations in athletes from distinctly abnormal findings suggestive of underlying pathology. Since the original 2010 European Society of Cardiology recommendations for ECG interpretation in athletes, ECG standards have evolved quickly over the last decade; pushed by a growing body of scientific data that both tests proposed criteria sets and establishes new evidence to guide refinements. On 26-27 February 2015, an international group of experts in sports cardiology, inherited cardiac disease, and sports medicine convened in Seattle, Washington, to update contemporary standards for ECG interpretation in athletes. The objective of the meeting was to define and revise ECG interpretation standards based on new and emerging research and to develop a clear guide to the proper evaluation of ECG abnormalities in athletes. This statement represents an international consensus for ECG interpretation in athletes and provides expert opinion-based recommendations linking specific ECG abnormalities and the secondary evaluation for conditions associated with SCD.

  14. Electrocardiographic Left Ventricular Hypertrophy as a Predictor of Cardiovascular Disease Independent of Left Ventricular Anatomy in Persons ≥ 65 Years of Age

    PubMed Central

    Leigh, J. Adam; O’Neal, Wesley T.; Soliman, Elsayed Z.

    2016-01-01

    Left ventricular hypertrophy (LVH) diagnosed by electrocardiography (ECG-LVH) and echocardiography (echo-LVH) are independently associated with an increased risk of cardiovascular disease (CVD) events. However, it is unknown if ECG-LVH retains its predictive properties independent of left ventricular anatomy. We compared the risk of CVD associated with ECG-LVH and echo-LVH in 4,076 participants (41% male, 86% white) from the Cardiovascular Health Study (CHS), who were free of baseline CVD. ECG-LVH was defined with Minnesota ECG Classification criteria from baseline ECG data. Echo-LVH was defined by sex-specific left ventricular mass values normalized to body surface area (male: >102 g/m2; female: >88 g/m2). ECG-LVH was detected in 144 (3.5%) participants and echo-LVH in 430 (11%) participants. Over a median follow-up of 10.6 years, 2,274 CVD events occurred. In a multivariable Cox regression analysis adjusted for common CVD risk factors, ECG-LVH (HR=1.84, 95%CI=1.51, 2.24) and echo-LVH (HR=1.35, 95%CI=1.19, 1.54) were associated with an increased risk for CVD events. The association between ECG-LVH and CVD events was not substantively altered with further adjustment for echo-LVH (HR=1.76, 95%CI=1.45, 2.15). In conclusion, the association of ECG-LVH with CVD events is not dependent on echo-LVH. This finding provides support to the concept that ECG-LVH is an electrophysiologic marker with predictive properties independent of left ventricular anatomy. PMID:27067620

  15. Smartphone ECG for evaluation of STEMI: results of the ST LEUIS Pilot Study.

    PubMed

    Muhlestein, Joseph Boone; Le, Viet; Albert, David; Moreno, Fidela Ll; Anderson, Jeffrey L; Yanowitz, Frank; Vranian, Robert B; Barsness, Gregory W; Bethea, Charles F; Severance, Harry W; Ramo, Barry; Pierce, John; Barbagelata, Alejandro; Muhlestein, Joseph Brent

    2015-01-01

    12-lead ECG is a critical component of initial evaluation of cardiac ischemia, but has traditionally been limited to large, dedicated equipment in medical care environments. Smartphones provide a potential alternative platform for the extension of ECG to new care settings and to improve timeliness of care. To gain experience with smartphone electrocardiography prior to designing a larger multicenter study evaluating standard 12-lead ECG compared to smartphone ECG. 6 patients for whom the hospital STEMI protocol was activated were evaluated with traditional 12-lead ECG followed immediately by a smartphone ECG using right (VnR) and left (VnL) limb leads for precordial grounding. The AliveCor™ Heart Monitor was utilized for this study. All tracings were taken prior to catheterization or immediately after revascularization while still in the catheterization laboratory. The smartphone ECG had excellent correlation with the gold standard 12-lead ECG in all patients. Four out of six tracings were judged to meet STEMI criteria on both modalities as determined by three experienced cardiologists, and in the remaining two, consensus indicated a non-STEMI ECG diagnosis. No significant difference was noted between VnR and VnL. Smartphone based electrocardiography is a promising, developing technology intended to increase availability and speed of electrocardiographic evaluation. This study confirmed the potential of a smartphone ECG for evaluation of acute ischemia and the feasibility of studying this technology further to define the diagnostic accuracy, limitations and appropriate use of this new technology. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Ability of a 5-minute electrocardiography (ECG) for predicting arrhythmias in Doberman Pinschers with cardiomyopathy in comparison with a 24-hour ambulatory ECG.

    PubMed

    Wess, G; Schulze, A; Geraghty, N; Hartmann, K

    2010-01-01

    Ventricular premature contractions (VPCs) are common in the occult stage of cardiomyopathy in Doberman Pinschers. Although the gold standard for detecting arrhythmia is the 24-hour ambulatory electrocardiography (ECG) (Holter), this method is more expensive, time-consuming and often not as readily available as common ECG. Comparison of 5-minute ECGs with Holter examinations. Eight hundred and seventy-five 5-minute ECGs and Holter examinations of 431 Doberman Pinschers. Each examination included a 5-minute ECG and Holter examination. A cut-off value of > 100 VPCs/24 hours using Holter was considered diagnostic for the presence of cardiomyopathy. Statistical evaluation included calculation of sensitivity, specificity, positive predictive value, and negative predictive value. Holter examinations revealed > 100 VPCs/24 hours in 204/875 examinations. At least 1 VPC during a 5-minute ECG was detected in 131 (64.2%) of these 204 examinations. No VPCs were found in the 5-minute ECG in 73 (35.8%) examinations of affected Doberman Pinschers. A 5-minute ECG with at least 1 VPC as cut-off had a sensitivity of 64.2%, a specificity of 96.7%, a positive predictive value of 85.6% and a negative predictive value of 89.9% for the presence of > 100 VPCs/24 hours. A 5-minute ECG is a rather insensitive method for detecting arrhythmias in Doberman Pinschers. However, the occurrence of at least 1 VPC in 5 minutes strongly warrants further examination of the dog, because specificity (96.7%) and positive predictive value (85.6%) are high and could suggest occult cardiomyopathy.

  17. Electrocardiographic Abnormalities in Elderly Chagas Disease Patients: 10‐Year Follow‐Up of the Bambuí Cohort Study of Aging

    PubMed Central

    Ribeiro, Antonio Luiz P.; Marcolino, Milena S.; Prineas, Ronald J.; Lima‐Costa, Maria Fernanda

    2014-01-01

    Background Electrocardiography has been considered an important tool in the management of Chagas disease (ChD) patients, although its value in elderly infected patients is unknown. This study was designed to investigate the prevalence and prognostic value of electrocardiographic abnormalities in Trypanosoma cruzi infected and noninfected older adults. Methods and Results We studied 1462 participants in Bambuí City, Brazil, with electrocardiogram (ECG) records classified by the Minnesota Code. Follow‐up time was 10 years; the endpoint was mortality. Adjustment for potential confounding variables included age, gender, conventional risk factors, and B‐type natriuretic peptide (BNP). The mean age was 69 years (60.9% women). The prevalence of ChD was 38.1% (n=557). ECG abnormalities were more frequent in ChD patients (87.6% versus 77.7%, P<0.001). Right bundle branch block (RBBB) with left anterior hemiblock (LAH) was strongly related to ChD (OR: 11.99 [5.60 to 25.69]). During the mean follow‐up time of 8.7 years, 556 participants died (253 with ChD), and only 89 were lost to follow‐up. ECG variables of independent prognostic value for death in ChD included absence of sinus rhythm, frequent ventricular and supraventricular premature beats, atrial fibrillation, RBBB, old and possible old myocardial infarction, and left ventricular hypertrophy. The presence of any major ECG abnormalities doubled the risk of death in ChD patients (HR: 2.18 [1.35 to 3.53]), but it also increased the risk in non‐ChD subjects (HR: 1.50 [1.07 to 2.10]); the risk of death increased with the number of major abnormalities in the same patient. Conclusion ECG abnormalities are more common among elderly Chagas disease patients and strongly predict adverse outcomes. PMID:24510116

  18. Vectorcardiographic diagnostic & prognostic information derived from the 12-lead electrocardiogram: Historical review and clinical perspective.

    PubMed

    Man, Sumche; Maan, Arie C; Schalij, Martin J; Swenne, Cees A

    2015-01-01

    In the course of time, electrocardiography has assumed several modalities with varying electrode numbers, electrode positions and lead systems. 12-lead electrocardiography and 3-lead vectorcardiography have become particularly popular. These modalities developed in parallel through the mid-twentieth century. In the same time interval, the physical concepts underlying electrocardiography were defined and worked out. In particular, the vector concept (heart vector, lead vector, volume conductor) appeared to be essential to understanding the manifestations of electrical heart activity, both in the 12-lead electrocardiogram (ECG) and in the 3-lead vectorcardiogram (VCG). Not universally appreciated in the clinic, the vectorcardiogram, and with it the vector concept, went out of use. A revival of vectorcardiography started in the 90's, when VCGs were mathematically synthesized from standard 12-lead ECGs. This facilitated combined electrocardiography and vectorcardiography without the need for a special recording system. This paper gives an overview of these historical developments, elaborates on the vector concept and seeks to define where VCG analysis/interpretation can add diagnostic/prognostic value to conventional 12-lead ECG analysis. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. A multi-sensor monitoring system of human physiology and daily activities.

    PubMed

    Doherty, Sean T; Oh, Paul

    2012-04-01

    To present the design and pilot test results of a continuous multi-sensor monitoring system of real-world physiological conditions and daily life (activities, travel, exercise, and food consumption), culminating in a Web-based graphical decision-support interface. The system includes a set of wearable sensors wirelessly connected to a "smartphone" with a continuously running software application that compresses and transmits the data to a central server. Sensors include a Global Positioning System (GPS) receiver, electrocardiogram (ECG), three-axis accelerometer, and continuous blood glucose monitor. A food/medicine diary and prompted recall activity diary were also used. The pilot test involved 40 type 2 diabetic patients monitored over a 72-h period. All but three subjects were successfully monitored for the full study period. Smartphones proved to be an effective hub for managing multiple streams of data but required attention to data compression and battery consumption issues. ECG, accelerometer, and blood glucose devices performed adequately as long as subjects wore them. GPS tracking for a full day was feasible, although significant efforts are needed to impute missing data. Activity detection algorithms were successful in identifying activities and trip modes but could benefit by incorporating accelerometer data. The prompted recall diary was an effective tool for augmenting algorithm results, although subjects reported some difficulties with it. The food and medicine diary was completed fully, although end times and medicine dosages were occasionally missing. The unique combination of sensors holds promise for increasing accuracy and reducing burden associated with collecting individual-level activity and physiological data under real-world conditions, but significant data processing issues remain. Such data will provide new opportunities to explore the impacts of human geography and daily lifestyle on health at a fine spatial/temporal scale.

  20. Monitoring cardiac motion in CT using a continuous wave radar embedded in the patient table.

    PubMed

    Pfanner, Florian; Allmendinger, Thomas; Bohn, Birgit; Flohr, Thomas; Kachelrieß, Marc

    2014-08-01

    To avoid motion artifacts, medical imaging devices are often synchronized with the patient's cardiac motion. Today, the ECG is used to determine the heartbeat and therewith trigger the imaging device. However, the ECG requires additional effort to prepare the patient, e.g., mount and wire electrodes and it is not able to determine the motion of the heart. An interesting alternative to assess the cardiac motion is continuous wave radar. The aim of this work is to evaluate such a radar system focusing on measuring the cardiac motion. A radar system operating in the 860 MHz band is used. In the intended application of the radar system, the antennas are located close to the patient's body, for example, inside the table of a CT system. The radar waves propagate into the patient's body and are reflected at tissue boundaries, for example, at the borderline between muscle and adipose tissue, or at the boundaries of organs. Here, the authors focus on the detection of cardiac motion. The radar system consists of hardware as well as of dedicated signal processing software to extract the desired information from the radar signals. The radar system hardware and the signal processing algorithms were tested with data from ten volunteers. As a reference, the ECG was recorded simultaneously with the radar measurements. Additionally, ultrasound measurements are performed and compared with the motion information from the radar data. According to the authors' measurements on volunteers (test persons), the heartbeat and heart rate can be detected well using the proposed radar system. The authors were further able to extract the amplitude and phase of the heart motion itself from the radar data. This was confirmed by the ultrasound measurements. However, this motion assessment is dependent on the antenna position and it remains unclear which antenna sees the motion that is the most relevant to CT imaging. A continuous wave radar operating in the near field of the antennas can be used to determine the heartbeat and the cardiac motion of humans without special patient preparation. The authors' radar system is very close to the patient because it is embedded in the patient table, but it has no direct contact to the patient or to the patient skin (as it would be necessary to acquire the ECG of the patient). Therefore, radar motion monitoring does not require special patient preparation. In contrast to other methods used today, this is a significant improvement. The authors' radar system may allow to trigger a CT scan in dependency of the cardiac phase, without requiring an ECG, and it allows to determine quiet, and thus favorable, heart phases prior to the scan start.

Top