Sample records for eds diffuse reflectance

  1. BiOBr microspheres for photocatalytic degradation of an anionic dye

    NASA Astrophysics Data System (ADS)

    Mera, Adriana C.; Váldes, Héctor; Jamett, Fabiola J.; Meléndrez, M. F.

    2017-03-01

    BiOBr microspheres were obtained using a solvothermal synthesis route in the presence of ethylene glycol and KBr at 145 °C, for 18 h. BiOBr microspheres were characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), transmission electron microscopy (TEM), X-ray diffraction (XRD), thermogravimetric analysis (TGA), nitrogen adsorption-desorption isotherms analysis, diffuse reflectance spectroscopy (DRS), and diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS). Additionally, the theoretical and experimental isoelectric points (IEP) of BiOBr nanostructured microspheres were determined, and pH's influence on the degradation of an anionic dye (methyl orange) under simulated solar radiation was analyzed. Results show that 97% of methyl orange is removed at pH 2 after 60 min of photocatalytic reaction. Finally, DRIFTS studies permit the proposal of a surface reaction mechanism of the photocatalytic oxidation of MO using BiOBr microspheres.

  2. ReflectED: Evaluation Report and Executive Summary

    ERIC Educational Resources Information Center

    Motteram, Gary; Choudry, Sophina; Kalambouka, Afroditi; Hutcheson, Graeme; Barton, Hutcheson

    2016-01-01

    The ReflectED programme was developed by Rosendale Primary School to improve pupils' metacognition--their ability to think about and manage their own learning. This includes the skills of setting and monitoring goals, assessing progress, and identifying personal strengths and challenges. ReflectED consists of 28, weekly, half-hour lessons, which…

  3. Relationship between tissue tension and thermal diffusion to peripheral tissue using an energy device.

    PubMed

    Kondo, Akihiro; Nishizawa, Yuji; Ito, Masaaki; Saito, Norio; Fujii, Satoshi; Akamoto, Shintaro; Fujiwara, Masao; Okano, Keiichi; Suzuki, Yasuyuki

    2016-08-01

    The aim of the study was to assess the relationship between tissue tension and thermal diffusion to peripheral tissues using an electric scalpel, ultrasonically activated device, or a bipolar sealing system. The mesentery of pigs was excised with each energy device (ED) at three tissue tensions (0, 300, 600 g). The excision time and thermal diffusion area were monitored with thermography, measured for each ED, and then histologically examined. Correlations between tissue tension and thermal diffusion area were examined. The excision time was inversely correlated with tissue tension for all ED (electric scalpel, r = 0.718; ultrasonically activated device, r = 0.949; bipolar sealing system, r = 0.843), and tissue tension was inversely correlated with the thermal diffusion area with the electric scalpel (r = 0.718) and bipolar sealing system (r = 0.869). Histopathologically, limited deep thermal denaturation occurred at a tension of 600 g with all ED. We conclude that thermal damage can be avoided with adequate tissue tension when any ED is used. © 2016 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  4. Normalized sensitivities and parameter identifiability of in situ diffusion experiments on Callovo Oxfordian clay at Bure site

    NASA Astrophysics Data System (ADS)

    Samper, J.; Dewonck, S.; Zheng, L.; Yang, Q.; Naves, A.

    Diffusion of inert and reactive tracers (DIR) is an experimental program performed by ANDRA at Bure underground research laboratory in Meuse/Haute Marne (France) to characterize diffusion and retention of radionuclides in Callovo-Oxfordian (C-Ox) argillite. In situ diffusion experiments were performed in vertical boreholes to determine diffusion and retention parameters of selected radionuclides. C-Ox clay exhibits a mild diffusion anisotropy due to stratification. Interpretation of in situ diffusion experiments is complicated by several non-ideal effects caused by the presence of a sintered filter, a gap between the filter and borehole wall and an excavation disturbed zone (EdZ). The relevance of such non-ideal effects and their impact on estimated clay parameters have been evaluated with numerical sensitivity analyses and synthetic experiments having similar parameters and geometric characteristics as real DIR experiments. Normalized dimensionless sensitivities of tracer concentrations at the test interval have been computed numerically. Tracer concentrations are found to be sensitive to all key parameters. Sensitivities are tracer dependent and vary with time. These sensitivities are useful to identify which are the parameters that can be estimated with less uncertainty and find the times at which tracer concentrations begin to be sensitive to each parameter. Synthetic experiments generated with prescribed known parameters have been interpreted automatically with INVERSE-CORE 2D and used to evaluate the relevance of non-ideal effects and ascertain parameter identifiability in the presence of random measurement errors. Identifiability analysis of synthetic experiments reveals that data noise makes difficult the estimation of clay parameters. Parameters of clay and EdZ cannot be estimated simultaneously from noisy data. Models without an EdZ fail to reproduce synthetic data. Proper interpretation of in situ diffusion experiments requires accounting for filter, gap and EdZ. Estimates of the effective diffusion coefficient and the porosity of clay are highly correlated, indicating that these parameters cannot be estimated simultaneously. Accurate estimation of De and porosities of clay and EdZ is only possible when the standard deviation of random noise is less than 0.01. Small errors in the volume of the circulation system do not affect clay parameter estimates. Normalized sensitivities as well as the identifiability analysis of synthetic experiments provide additional insight on inverse estimation of in situ diffusion experiments and will be of great benefit for the interpretation of real DIR in situ diffusion experiments.

  5. The effect of dispersed Petrobaltic oil droplet size on photosynthetically active radiation in marine environment.

    PubMed

    Haule, Kamila; Freda, Włodzimierz

    2016-04-01

    Oil pollution in seawater, primarily visible on sea surface, becomes dispersed as an effect of wave mixing as well as chemical dispersant treatment, and forms spherical oil droplets. In this study, we examined the influence of oil droplet size of highly dispersed Petrobaltic crude on the underwater visible light flux and the inherent optical properties (IOPs) of seawater, including absorption, scattering, backscattering and attenuation coefficients. On the basis of measured data and Mie theory, we calculated the IOPs of dispersed Petrobaltic crude oil in constant concentration, but different log-normal size distributions. We also performed a radiative transfer analysis, in order to evaluate the influence on the downwelling irradiance Ed, remote sensing reflectance Rrs and diffuse reflectance R, using in situ data from the Baltic Sea. We found that during dispersion, there occurs a boundary size distribution characterized by a peak diameter d0  = 0.3 μm causing a maximum E d increase of 40% within 0.5-m depth, and the maximum Ed decrease of 100% at depths below 5 m. Moreover, we showed that the impact of size distribution on the "blue to green" ratios of Rrs and R varies from 24% increase to 27% decrease at the same crude oil concentration.

  6. Optical and electrical studies of cerium mixed oxides

    NASA Astrophysics Data System (ADS)

    Sherly, T. R.; Raveendran, R.

    2014-10-01

    The fast development in nanotechnology makes enthusiastic interest in developing nanomaterials having tailor made properties. Cerium mixed oxide materials have received great attention due to their UV absorption property, high reactivity, stability at high temperature, good electrical property etc and these materials find wide applications in solid oxide fuel cells, solar control films, cosmetics, display units, gas sensors etc. In this study cerium mixed oxide compounds were prepared by co-precipitation method. All the samples were doped with Zn (II) and Fe (II). Preliminary characterizations such as XRD, SEM / EDS, TEM were done. UV - Vis, Diffuse reflectance, PL, FT-IR, Raman and ac conductivity studies of the samples were performed.

  7. The EdD Cohort Experience: Students' Reflection on the Program

    ERIC Educational Resources Information Center

    Atabay, Kyle; Cravalho, Erika K.; Demirbag, Jocelyn Romero; Ka'ai, Elsa Pua; Kaneshiro, Alyson; Nakasato, Steve

    2017-01-01

    Presented as a collection of short essays, the authors of this article reflect on their experience in the University of Hawaii at Manoa EdD program and the questions, "What have you been able to take away from the experience?" and "What are you doing now that the EdD made possible?" The authors entered the program with a wealth…

  8. Crystal Structure, Magnetic and Optical Properties of Mn-Doped BiFeO₃ by Hydrothermal Synthesis.

    PubMed

    Zhang, Ning; Wei, Qinhua; Qin, Laishun; Chen, Da; Chen, Zhi; Niu, Feng; Wang, Jiangying; Huanag, Yuexiang

    2017-01-01

    In this paper, Mn doped BiFeO₃ were firstly synthesized by hydrothermal process. The influence of Mn doping on structural, optical and magnetic properties of BiFeO₃ was studied. The different amounts of Mn doping in BiFeO₃ were characterized by X-ray diffraction, Scanning Electron Microscope, Energy Dispersive X-ray Spectroscope, UV-Vis diffuse reflectance spectroscopy and magnetic measurements. The X-ray diffraction (XRD) patterns confirmed the formation of pure phase rhombohedral structure in BiFe(1−x) Mn (x) O₃ (x = 0.01, 0.03, 0.05, 0.07) samples. The morphologies and chemical compositions of as-prepared samples could be observed by Scanning Electron Microscope (SEM) and Energy Dispersive X-ray Spectroscope (EDS). A relative large saturated magnetization (Ms) of 0.53 emu/g for x = 0.07 sample was obtained at room temperature, which is considered to be Mn ions doping. UV-Vis diffuse reflectance spectroscopy showed strong absorption of light in the range of 200–1000 nm, indicating the optical band gap in the visible region for these samples. This implied that BiFe(1−x) Mn(x)O₃ may be a potential photocatalyst for utilizing solar energy.

  9. Vacuum ultraviolet coatings of Al protected with MgF(2) prepared both by ion-beam sputtering and by evaporation.

    PubMed

    Fernández-Perea, Mónica; Larruquert, Juan I; Aznárez, José A; Pons, Alicia; Méndez, José A

    2007-08-01

    Ion-beam sputtering (IBS) and evaporation are the two deposition techniques that have been used to deposit coatings of Al protected with MgF(2) with high reflectance in the vacuum ultraviolet down to 115 nm. Evaporation deposited (ED) Al protected with IBS MgF(2) resulted in a larger (smaller) reflectance below (above) 125 nm than the well-known all-evaporated coatings. A similar comparison is obtained when the Al film is deposited by IBS instead of evaporation. The lower reflectance of the coatings protected with IBS versus ED MgF(2) above 125 nm is because of larger absorption of the former. Both nonprotected IBS Al, as well as IBS Al protected with ED MgF(2), resulted in a band of reflectance loss that was peaked at 127 and 157 nm, respectively. This result was attributed to the excitation of surface plasmons due to the enhancement of surface roughness with large spatial wave vectors in the sputter deposition. This reflectance loss for IBS Al protected with MgF(2) is small at the short (lambda~120 nm) and long (lambda<350 nm) wavelengths investigated. IBS Al protected with ED MgF(2) is thus a promising coating for these two spectral regions. Coatings protected with IBS MgF(2) resulted in a reflectance as high as coatings protected with ED MgF(2) at wavelengths longer than 550 nm, whereas the former had a lower reflectance below this wavelength.

  10. Conductance fluctuation of edge-disordered graphene nanoribbons: Crossover from diffusive transport to Anderson localization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takashima, Kengo; Yamamoto, Takahiro, E-mail: takahiro@rs.tus.ac.jp; Department of Liberal Arts

    Conductance fluctuation of edge-disordered graphene nanoribbons (ED-GNRs) is examined using the non-equilibrium Green's function technique combined with the extended Hückel approximation. The mean free path λ and the localization length ξ of the ED-GNRs are determined to classify the quantum transport regimes. In the diffusive regime where the length L{sub c} of the ED-GNRs is much longer than λ and much shorter than ξ, the conductance histogram is given by a Gaussian distribution function with universal conductance fluctuation. In the localization regime where L{sub c}≫ξ, the histogram is no longer the universal Gaussian distribution but a lognormal distribution that characterizesmore » Anderson localization.« less

  11. Pensive Professionalism: The Role of 'Required Reflection' on a Professional Doctorate

    ERIC Educational Resources Information Center

    Cunningham, Bryan

    2018-01-01

    This short paper examines the origins and nature of the reflective writing that is presently required on one part-taught doctorate in education (EdD) programme. It explores the various ways in which EdD candidates have engaged with self-reflection, using a number of extracts from writing submitted for formal assessments (including of the doctoral…

  12. ZnO:Gd nanocrystals for fluorescent applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Divya, N. K., E-mail: divyank90@gmail.com; Pradyumnan, P. P.

    2016-05-23

    Gadolinium doped ZnO crystals within the solubility limit of gadolinium in ZnO matrix were prepared by solid state reaction technique. The method is relatively less expense and enables the production in large scale. The samples were characterised by X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDS), scanning electron microscopy (SEM), UV/Vis diffuse reflectance spectroscopy and photoluminescence techniques. Fluorescent property studies of gadolinium doped ZnO at room temperature show enhanced visible light emission due to the defects and oxygen vacancies produced via doping. This work reports the impact of gadolinium doping in the structural, optical and luminescent properties of ZnO inmore » detail.« less

  13. Complexities of management of a urostomy in Ehlers-Danlos syndrome: a reflective account.

    PubMed

    Oxenham, Julie

    Mary (pseudonym) is a 30-year-old woman who underwent a urinary diversion and formation of an ileal conduit/urostomy (urinary stoma) due to the formation of multiple bladder diverticula, which caused micturition difficulties and recurrent urinary tract infections with associated pain and discomfort. The bladder diverticula were caused by Ehlers-Danlos syndrome (EDS), a hereditary disorder of the connective tissue or, particulary, defective collagen. Surgical intervention in patients with EDS is prone to complications due to poor wound healing, including issues of dehiscence, postoperative bleeding and poor uptake of anaesthesia and analgesia. After an initial presentation of the syndrome of EDS and Mary's history, this article offers a reflective account (informed by Gibbs' Reflective Cycle) and illustrates the complexities of caring for an individual with EDS who undergoes stoma formation. The author, a stoma care nurse, demonstrates how using purposeful reflection resulted in better understanding and awareness of caring for an individual with a rare syndrome and the nursing challenges this presented.

  14. Model of bidirectional reflectance distribution function for metallic materials

    NASA Astrophysics Data System (ADS)

    Wang, Kai; Zhu, Jing-Ping; Liu, Hong; Hou, Xun

    2016-09-01

    Based on the three-component assumption that the reflection is divided into specular reflection, directional diffuse reflection, and ideal diffuse reflection, a bidirectional reflectance distribution function (BRDF) model of metallic materials is presented. Compared with the two-component assumption that the reflection is composed of specular reflection and diffuse reflection, the three-component assumption divides the diffuse reflection into directional diffuse and ideal diffuse reflection. This model effectively resolves the problem that constant diffuse reflection leads to considerable error for metallic materials. Simulation and measurement results validate that this three-component BRDF model can improve the modeling accuracy significantly and describe the reflection properties in the hemisphere space precisely for the metallic materials.

  15. Computer Aided Design of Integrated Circuit Fabrication Processes for VLSI Devices

    DTIC Science & Technology

    1980-01-01

    diffusion coefficient and surface conc,,tration of the chlorine as well as any field present; X is related to the ratio ol the diffusion coefficient to...with polysilicon gat(. .ed contacts, the interaction of oxidation, segregation and diffusion in all regions of the simulation space is a critical

  16. In-situ XRD and EDS method study on the oxidation behaviour of Ni-Cu sulphide ore.

    PubMed

    Li, Guangshi; Cheng, Hongwei; Xiong, Xiaolu; Lu, Xionggang; Xu, Cong; Lu, Changyuan; Zou, Xingli; Xu, Qian

    2017-06-12

    The oxidation mechanism of sulfides is the key issue during the sulphide-metallurgy process. In this study, the phase transformation and element migration were clearly demonstrated by in-situ laboratory-based X-ray diffraction (XRD) and energy-dispersive X-ray spectroscopy (EDS), respectively. The reaction sequence and a four-step oxidation mechanism were proposed and identified. The elemental distribution demonstrated that at a low temperature, the Fe atoms diffused outward and the Ni/Cu atoms migrated toward the inner core, whereas the opposite diffusion processes were observed at a higher temperature. Importantly, the unique visual presentation of the oxidation behaviour provided by the combination of in-situ XRD and EDS might be useful for optimising the process parameters to improve the Ni/Cu extraction efficiency during Ni-Cu sulphide metallurgy.

  17. Islamic Resurgence in Algeria: The Rise of the Islamic Salvation Front

    DTIC Science & Technology

    1993-05-01

    Julien, Histolre de l’Afrique du Nord: Tunisie-Alg~rie- Maroc de la conqufte arabe A 1830, 2 ed., Roger LeTourneau ed., Paris, Payot, 1956. 4Jamil M...Nord. Tunisie-Alg~rie- Maroc de la conqu~te arabe A 1830. 2 ed. Roger LeTourneau, ed., Paris, Payot, 1956. El-Kenz, Ali. Algerian Reflections on Arab

  18. Adopting the edTPA as a High-Stakes Assessment: Resistance, Advocacy, and Reflection in Illinois

    ERIC Educational Resources Information Center

    Olson, Jennifer D.; Rao, Arthi B.

    2017-01-01

    The edTPA, a national performance assessment for teacher candidates, has seen rapid adoption across the country since its development in 2009. Against the national backdrop of high stakes testing and accountability, the edTPA was developed to be an indicator of teachers' readiness to teach. The varying perspectives and responses to edTPA in…

  19. Completing EdTPA: TSOL Candidate Performance and Reflection

    ERIC Educational Resources Information Center

    Micek, Timothy A.

    2017-01-01

    edTPA is a pre-service assessment process designed to determine if a new teacher is ready for the job. edTPA is part of a national movement towards the use of performance assessments in teacher education. As of 2014, 41 states (a) require a state-approved performance assessment like edTPA for program completion or for state licensure and/or state…

  20. Enhancing the ag precipitation by surface mechanical attrition treatment on Cu-Ag alloys

    NASA Astrophysics Data System (ADS)

    Liu, Jiabin; Zhang, Lehao; Liu, Jingjing; Huang, Liuyi; Gu, Hao; Fang, Youtong; Meng, Liang; Zhang, Jian

    2016-09-01

    The influence of surface mechanical attrition treatment (SMAT) on Ag precipitation in Cu-Ag alloys was investigated. Cu-6 wt% Ag was melt, cold rolled and solution treated to be Cu-Ag solid solution, which was either aged at 250 and 350 °C for 24 h directly or SMAT-ed before aging. Ag precipitates were hard be found in the directly aged Cu-Ag sample while they were observed clearly in the SMAT-ed counterpart at 250 °C. The Ag precipitates formed in the surface layer by SMAT are much coarser than those in the un-SMAT-ed sample. It is obvious that the precipitating behavior of Ag was promoted significantly by SMAT approach. A large number of defects were generated by SMAT and they were acting as fast atomic diffusion channels that facilitated the atomic diffusion of Ag.

  1. Nuanced aesthetic emotions: emotion differentiation is related to knowledge of the arts and curiosity.

    PubMed

    Fayn, Kirill; Silvia, Paul J; Erbas, Yasemin; Tiliopoulos, Niko; Kuppens, Peter

    2018-05-01

    The ability to distinguish between emotions is considered indicative of well-being, but does emotion differentiation (ED) in an aesthetic context also reflect deeper and more knowledgeable aesthetic experiences? Here we examine whether positive and negative ED in response to artistic stimuli reflects higher fluency in an aesthetic domain. Particularly, we test whether knowledge of the arts and curiosity are associated with more fine-grained positive and negative aesthetic experiences. A sample of 214 people rated their positive and negative feelings in response to various artworks including positive and negative themes. Positive ED was associated with the embracing sub-trait of curiosity that reflects engagement and enjoyment of novelty and complexity, but was unrelated to artistic knowledge and perceived comprehension. Negative ED was associated with higher curiosity and particularly more knowledge of the arts. This relationship was mediated by appraised comprehension suggesting that deeper engagement with art, by those with more art knowledge, is associated with more fine-grained emotional experiences. This finding extends ED beyond well-being research and suggests that more nuanced emotional experiences are more likely for those with expertise in the arts and motivation for exploration.

  2. Germania Quo Vadis?: Dynamics of Change in German Security Policy

    DTIC Science & Technology

    2007-06-01

    Keohane, Robert O., Michael Brecher and Frank Harveys, eds. Institutional Theory in international Relations. In: Millennial Reflections on International...Hegemony: Cooperation and Discord in the World Political Economy, (Princeton University Press, 1984), pp. 78-109; Robert O. Keohane, “ Institutional ... Theory in international Relations,” in Michael Brecher and Frank Harveys, eds., Millennial Reflections on International Studies (University of Michigan

  3. Rebooting the EdD

    ERIC Educational Resources Information Center

    Wergin, Jon F.

    2011-01-01

    In this essay, Jon Wergin reminds readers of the philosophical and historical foundations of the doctor of education (EdD) degree. He argues that the EdD should be based, in large part, on John Dewey's progressive ideals of democratization and Paulo Freire's concepts of emancipatory education. Drawing on theories of reflective practice,…

  4. Evaluation of emergency department performance - a systematic review on recommended performance and quality-in-care measures.

    PubMed

    Sørup, Christian Michel; Jacobsen, Peter; Forberg, Jakob Lundager

    2013-08-09

    Evaluation of emergency department (ED) performance remains a difficult task due to the lack of consensus on performance measures that reflects high quality, efficiency, and sustainability. To describe, map, and critically evaluate which performance measures that the published literature regard as being most relevant in assessing overall ED performance. Following the PRISMA guidelines, a systematic literature review of review articles reporting accentuated ED performance measures was conducted in the databases of PubMed, Cochrane Library, and Web of Science. Study eligibility criteria includes: 1) the main purpose was to discuss, analyse, or promote performance measures best reflecting ED performance, 2) the article was a review article, and 3) the article reported macro-level performance measures, thus reflecting an overall departmental performance level. A number of articles addresses this study's objective (n = 14 of 46 unique hits). Time intervals and patient-related measures were dominant in the identified performance measures in review articles from US, UK, Sweden and Canada. Length of stay (LOS), time between patient arrival to initial clinical assessment, and time between patient arrivals to admission were highlighted by the majority of articles. Concurrently, "patients left without being seen" (LWBS), unplanned re-attendance within a maximum of 72 hours, mortality/morbidity, and number of unintended incidents were the most highlighted performance measures that related directly to the patient. Performance measures related to employees were only stated in two of the 14 included articles. A total of 55 ED performance measures were identified. ED time intervals were the most recommended performance measures followed by patient centeredness and safety performance measures. ED employee related performance measures were rarely mentioned in the investigated literature. The study's results allow for advancement towards improved performance measurement and standardised assessment across EDs.

  5. Sulfur Nanoparticles Synthesis and Characterization from H2S Gas, Using Novel Biodegradable Iron Chelates in W/O Microemulsion

    NASA Astrophysics Data System (ADS)

    Deshpande, Aniruddha S.; Khomane, Ramdas B.; Vaidya, Bhalchandra K.; Joshi, Renuka M.; Harle, Arti S.; Kulkarni, Bhaskar D.

    2008-06-01

    Sulfur nanoparticles were synthesized from hazardous H2S gas using novel biodegradable iron chelates in w/o microemulsion system. Fe3+ malic acid chelate (0.05 M aqueous solution) was studied in w/o microemulsion containing cyclohexane, Triton X-100 and n-hexanol as oil phase, surfactant, co-surfactant, respectively, for catalytic oxidation of H2S gas at ambient conditions of temperature, pressure, and neutral pH. The structural features of sulfur nanoparticles have been characterized by X-ray diffraction (XRD), transmission electron microscope (TEM), energy dispersive spectroscopy (EDS), diffused reflectance infra-red Fourier transform technique, and BET surface area measurements. XRD analysis indicates the presence of α-sulfur. TEM analysis shows that the morphology of sulfur nanoparticles synthesized in w/o microemulsion system is nearly uniform in size (average particle size 10 nm) and narrow particle size distribution (in range of 5 15 nm) as compared to that in aqueous surfactant systems. The EDS analysis indicated high purity of sulfur (>99%). Moreover, sulfur nanoparticles synthesized in w/o microemulsion system exhibit higher antimicrobial activity (against bacteria, yeast, and fungi) than that of colloidal sulfur.

  6. Sulfur Nanoparticles Synthesis and Characterization from H2S Gas, Using Novel Biodegradable Iron Chelates in W/O Microemulsion

    PubMed Central

    2008-01-01

    Sulfur nanoparticles were synthesized from hazardous H2S gas using novel biodegradable iron chelates in w/o microemulsion system. Fe3+–malic acid chelate (0.05 M aqueous solution) was studied in w/o microemulsion containing cyclohexane, Triton X-100 andn-hexanol as oil phase, surfactant, co-surfactant, respectively, for catalytic oxidation of H2S gas at ambient conditions of temperature, pressure, and neutral pH. The structural features of sulfur nanoparticles have been characterized by X-ray diffraction (XRD), transmission electron microscope (TEM), energy dispersive spectroscopy (EDS), diffused reflectance infra-red Fourier transform technique, and BET surface area measurements. XRD analysis indicates the presence of α-sulfur. TEM analysis shows that the morphology of sulfur nanoparticles synthesized in w/o microemulsion system is nearly uniform in size (average particle size 10 nm) and narrow particle size distribution (in range of 5–15 nm) as compared to that in aqueous surfactant systems. The EDS analysis indicated high purity of sulfur (>99%). Moreover, sulfur nanoparticles synthesized in w/o microemulsion system exhibit higher antimicrobial activity (against bacteria, yeast, and fungi) than that of colloidal sulfur.

  7. Coupled Diffusion and Reaction Processes in Rock Matrices: Impact on Dilute Groundwater Plumes

    DTIC Science & Technology

    2015-12-28

    28 Figure 3.5.6 Plastic dish used for permanganate diffusion experiment ........................................ 32 Figure 3.6.5...Manganese profiles following permanganate experiments ................................... 78 Figure 4.4.4.3 Carbon profiles...Figure A.3 SEM images and EDS spectra of permanganate -reacted surfaces ........................... 107

  8. Prototype Development and Evaluation of Self-Cleaning Concentrated Solar Power Collectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mazumder, Malay K.; Horenstein, Mark N.; Joglekar, Nitin R.

    The feasibility of integrating and retrofitting transparent electrodynamic screens (EDS) on the front surfaces of solar collectors was established as a means to provide active self-cleaning properties for parabolic trough and heliostat reflectors, solar panels, and Fresnel lenses. Prototype EDS-integrated solar collectors, including second-surface glass mirrors, metallized Acrylic-film mirrors, and dielectric mirrors, were produced and tested in environmental test chambers for removing the dust layer deposited on the front surface of the mirrors. The evaluation of the prototype EDS-integrated mirrors was conducted using dust and environmental conditions that simulate the field conditions of the Mojave Desert. Test results showed thatmore » the specular reflectivity of the mirrors could be maintained at over 90% over a wide range of dust loadings ranging from 0 to 10 g/m 2, with particle diameter varying from 1 to 50 μm. The measurement of specular reflectivity (SR) was performed using a D&S Reflectometer at wavelength 660 nm. A non-contact reflectometer was designed and constructed for rapid measurement of specular reflectivity at the same wavelength. The use of this new noncontact instrument allowed us to measure SR before and after EDS activation. Several EDS prototypes were constructed and evaluated with different electrode configurations, electrode materials, and encapsulating dielectric materials.« less

  9. Nailfold capillary abnormalities in erectile dysfunction of systemic sclerosis: a EUSTAR group analysis.

    PubMed

    Keck, Andrea D; Foocharoen, Chingching; Rosato, Edoardo; Smith, Vanessa; Allanore, Yannick; Distler, Oliver; Stamenkovic, Bojana; Pereira Da Silva, José Antonio; Hadj Khelifa, Sondess; Denisov, Lev N; Hachulla, Eric; García de la Peña Lefebvre, Paloma; Sibilia, Jean; Airò, Paolo; Caramaschi, Paola; Müller-Ladner, Ulf; Wiland, Piotr; Walker, Ulrich A

    2014-04-01

    The objective of this study was to analyse an association between nailfold capillary abnormalities and the presence and severity of erectile dysfunction (ED) in men with SSc. A cross-sectional analysis of the prospective European League Against Rheumatism (EULAR) Scleroderma Trial and Research database was performed. Men with SSc were included if they had undergone nailfold capillaroscopy and simultaneous ED assessment with the 5-item International Index for Erectile Function (IIEF-5). Eighty-six men met the inclusion criteria. Eight men (9.3%) had not had sexual intercourse and could not be assigned an IIEF-5 score. Sixty-nine of the 78 men (88.5%) with an IIEF-5 score had nailfold capillary abnormalities, of whom 54 (78.3%) suffered from ED. Nine men (11.5%) had no nailfold capillary abnormalities, of whom six (66.7%) had ED (P = 0.44). ED was more frequent in older men (P = 0.002) and in men with diffuse disease (P = 0.06). Men with abnormal capillaroscopy had a higher median EULAR disease activity than men without (P = 0.02), a lower diffusing capacity of the lung (P = 0.001) and a higher modified Rodnan skin score (P = 0.04), but mean IIEF-5 scores did not differ [15.7 (S.D. 6.2) vs 15.7 (S.D. 6.3)]. IIEF-5 scores did not differ between men with early (n = 12), active (n = 27) or late (n = 27) patterns (IIEF-5 scores of 17.9, 16.3 and 14.7, respectively). There were no differences in the prevalence of early, active and late capillaroscopy patterns between men with or without ED. Neither the presence or absence of abnormal capillaroscopy findings nor the subdivision into early, active and late patterns is associated with coexistent ED in SSc.

  10. Important historical efforts at emergency department categorization in the United States and implications for regionalization.

    PubMed

    Mehrotra, Abhishek; Sklar, David P; Tayal, Vivek S; Kocher, Keith E; Handel, Daniel A; Myles Riner, R

    2010-12-01

    This article is drawn from a report created for the American College of Emergency Physicians (ACEP) Emergency Department (ED) Categorization Task Force and also reflects the proceedings of a breakout session, "Beyond ED Categorization-Matching Networks to Patient Needs," at the 2010 Academic Emergency Medicine consensus conference, "Beyond Regionalization: Integrated Networks of Emergency Care." The authors describe a brief history of the significant national and state efforts at categorization and suggest reasons why many of these efforts failed to persevere or gain wider implementation. The history of efforts to categorize hospital (and ED) emergency services demonstrates recognition of the potential benefits of categorization, but reflects repeated failures to implement full categorization systems or limited excursions into categorization through licensing of EDs or designation of receiving and referral facilities. An understanding of the history of hospital and ED categorization could better inform current efforts to develop categorization schemes and processes. 2010 by the Society for Academic Emergency Medicine.

  11. Reflection Matrix Method for Controlling Light After Reflection From a Diffuse Scattering Surface

    DTIC Science & Technology

    2016-12-22

    reflective inverse diffusion, which was a proof-of-concept experiment that used phase modulation to shape the wavefront of a laser causing it to refocus...after reflection from a rough surface. By refocusing the light, reflective inverse diffusion has the potential to eliminate the complex radiometric model...photography. However, the initial reflective inverse diffusion experiments provided no mathematical background and were conducted under the premise that the

  12. Capturing the 'art' of emergency medicine: Does film foster reflection in medical students?

    PubMed

    Brand, Gabrielle; Wise, Steve; Siddiqui, Zarrin S; Celenza, Antonio; Fatovich, Daniel M

    2017-08-01

    Integrating arts and humanities-based pedagogy into curricula is of growing interest among medical educators, particularly how it promotes reflection and empathy. Our aim was to explore whether a 2.50 min film titled 'The Art of the ED' stimulated reflective learning processes in a group of first year medical students. The film was shown prior to their first clinical placement in an ED. Student participation was voluntary and not assessable. Using an exploratory qualitative research approach, this study drew on data collected from students' individual written reflections, exploring their perceptions towards clinical experience in an emergency medicine (EM) attachment. A total of 123 (51% of 240) students submitted a reflection. The qualitative data revealed three main themes: the opportunity for students to preview EM ('While watching the film, I felt like I was the patient and the doctor all at once, in that I was living the experience both from within and as an observer …'); exposed the reality of ED; and fostered a growing awareness of the fragility of human life. These findings highlight how visual methodologies (like film) create a safe, non-threatening space to access, experience and process emotion around their perceptions towards EM, and to anticipate and emotionally prepare for their impending clinical experience in the ED. These data support the use of visual methodologies to foster reflective processes that assist medical students to integrate the 'art' of EM, and the development and commitment of core doctoring values of empathy, service and respect for patients. © 2017 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  13. Diffuse reflectance relations based on diffusion dipole theory for large absorption and reduced scattering

    NASA Astrophysics Data System (ADS)

    Bremmer, Rolf H.; van Gemert, Martin J. C.; Faber, Dirk J.; van Leeuwen, Ton G.; Aalders, Maurice C. G.

    2013-08-01

    Diffuse reflectance spectra are used to determine the optical properties of biological samples. In medicine and forensic science, the turbid objects under study often possess large absorption and/or scattering properties. However, data analysis is frequently based on the diffusion approximation to the radiative transfer equation, implying that it is limited to tissues where the reduced scattering coefficient dominates over the absorption coefficient. Nevertheless, up to absorption coefficients of 20 m at reduced scattering coefficients of 1 and 11.5 mm-1, we observed excellent agreement (r2=0.994) between reflectance measurements of phantoms and the diffuse reflectance equation proposed by Zonios et al. [Appl. Opt. 38, 6628-6637 (1999)], derived as an approximation to one of the diffusion dipole equations of Farrell et al. [Med. Phys. 19, 879-888 (1992)]. However, two parameters were fitted to all phantom experiments, including strongly absorbing samples, implying that the reflectance equation differs from diffusion theory. Yet, the exact diffusion dipole approximation at high reduced scattering and absorption also showed agreement with the phantom measurements. The mathematical structure of the diffuse reflectance relation used, derived by Zonios et al. [Appl. Opt. 38, 6628-6637 (1999)], explains this observation. In conclusion, diffuse reflectance relations derived as an approximation to the diffusion dipole theory of Farrell et al. can analyze reflectance ratios accurately, even for much larger absorption than reduced scattering coefficients. This allows calibration of fiber-probe set-ups so that the object's diffuse reflectance can be related to its absorption even when large. These findings will greatly expand the application of diffuse reflection spectroscopy. In medicine, it may allow the use of blue/green wavelengths and measurements on whole blood, and in forensic science, it may allow inclusion of objects such as blood stains and cloth at crime scenes.

  14. Evaluation of emergency department performance – a systematic review on recommended performance and quality-in-care measures

    PubMed Central

    2013-01-01

    Background Evaluation of emergency department (ED) performance remains a difficult task due to the lack of consensus on performance measures that reflects high quality, efficiency, and sustainability. Aim To describe, map, and critically evaluate which performance measures that the published literature regard as being most relevant in assessing overall ED performance. Methods Following the PRISMA guidelines, a systematic literature review of review articles reporting accentuated ED performance measures was conducted in the databases of PubMed, Cochrane Library, and Web of Science. Study eligibility criteria includes: 1) the main purpose was to discuss, analyse, or promote performance measures best reflecting ED performance, 2) the article was a review article, and 3) the article reported macro-level performance measures, thus reflecting an overall departmental performance level. Results A number of articles addresses this study’s objective (n = 14 of 46 unique hits). Time intervals and patient-related measures were dominant in the identified performance measures in review articles from US, UK, Sweden and Canada. Length of stay (LOS), time between patient arrival to initial clinical assessment, and time between patient arrivals to admission were highlighted by the majority of articles. Concurrently, “patients left without being seen” (LWBS), unplanned re-attendance within a maximum of 72 hours, mortality/morbidity, and number of unintended incidents were the most highlighted performance measures that related directly to the patient. Performance measures related to employees were only stated in two of the 14 included articles. Conclusions A total of 55 ED performance measures were identified. ED time intervals were the most recommended performance measures followed by patient centeredness and safety performance measures. ED employee related performance measures were rarely mentioned in the investigated literature. The study’s results allow for advancement towards improved performance measurement and standardised assessment across EDs. PMID:23938117

  15. The diagnostic value of EEGs in patients with syncope.

    PubMed

    Abubakr, Abuhuziefa; Wambacq, Ilse

    2005-05-01

    We retrospectively reviewed reports of all EEGs performed at the New Jersey Neuroscience Institute at JFK Hospital between January 1999 and December 2003. Of 9234 EEGs performed, 1094 were of patients with syncope. Among patients with syncope, 67.18% of the EEGs were normal and 28.15% showed diffuse and focal slowing. Only 1.46% of the EEGs showed epileptiform discharges (EDs). This is similar to the incidence of EDs in healthy adults. The presence of EDs did not change the management of these patients. Therefore, EEGs have very low yield and should not be routinely obtained in patients with syncope.

  16. Measurement and Modeling of the Optical Scattering Properties of Crop Canopies

    NASA Technical Reports Server (NTRS)

    Vanderbilt, V. C. (Principal Investigator)

    1985-01-01

    The specular reflection process is shown to be a key aspect of radiation transfer by plant canopies. Polarization measurements are demonstrated as the tool for determining the specular and diffuse portions of the canopy radiance. The magnitude of the specular fraction of the reflectance is significant compared to the magnitude of the diffuse fraction. Therefore, it is necessary to consider specularly reflected light in developing and evaluating light-canopy interaction models for wheat canopies. Models which assume leaves are diffuse reflectors correctly predict only the diffuse fraction of the canopy reflectance factor. The specular reflectance model, when coupled with a diffuse leaf model, would predict both the specular and diffuse portions of the reflectance factor. The specular model predicts and the data analysis confirms that the single variable, angle of incidence of specularly reflected sunlight on the leaf, explains much of variation in the polarization data as a function of view-illumination directions.

  17. Book Reviews.

    ERIC Educational Resources Information Center

    Fein, Greta G.; And Others

    1993-01-01

    Reviews the following books: "Child Care in Context" (Lamb et al., Eds.); "Making Friends in School: Promoting Relationships in Early Childhood" (Ramsay); "The Epigenesis of Mind: Essays on Biology and Cognition" (Carey and Gelman, Eds.); "Moral Maturity: Measuring the Development of Sociomoral Reflection"…

  18. Optical and adhesive properties of dust deposits on solar mirrors and their effects on specular reflectivity and electrodynamic cleaning for mitigating energy-yield loss

    NASA Astrophysics Data System (ADS)

    Mazumder, Malay; Yellowhair, Julius; Stark, Jeremy; Heiling, Calvin; Hudelson, John; Hao, Fang; Gibson, Hannah; Horenstein, Mark

    2014-10-01

    Large-scale solar plants are mostly installed in semi-arid and desert areas. In those areas, dust layer buildup on solar collectors becomes a major cause for energy yield loss. Development of transparent electrodynamic screens (EDS) and their applications for self-cleaning operation of solar mirrors are presented with a primary focus on the removal dust particles smaller than 30 µm in diameter while maintaining specular reflection efficiency < 90%. An EDS consists of thin rectangular array of parallel transparent conducting electrodes deposited on a transparent dielectric surface. The electrodes are insulated from each other and are embedded within a thin transparent dielectric film. The electrodes are activated using three-phase high-voltage pulses at low current (< 1 mA/m2 ). The three-phase electric field charges the deposited particles, lifts them form the substrate by electrostatic forces and propels the dust layer off of the collector's surface by a traveling wave. The cleaning process takes less than 2 minutes; needs energy less than 1 Wh/m2 without requiring any water or manual labor. The reflection efficiency can be restored > 95% of the original clean-mirror efficiency. We briefly present (1) loss of specular reflection efficiency as a function of particle size distribution of deposited dust, and (2) the effects of the electrode design and materials used for minimizing initial loss of specular reflectivity in producing EDS-integrated solar mirrors. Optimization of EDS by using a figure of merit defined by the ratio of dust removal efficiency to the initial loss of specular reflection efficiency is discussed.

  19. An improved method to estimate reflectance parameters for high dynamic range imaging

    NASA Astrophysics Data System (ADS)

    Li, Shiying; Deguchi, Koichiro; Li, Renfa; Manabe, Yoshitsugu; Chihara, Kunihiro

    2008-01-01

    Two methods are described to accurately estimate diffuse and specular reflectance parameters for colors, gloss intensity and surface roughness, over the dynamic range of the camera used to capture input images. Neither method needs to segment color areas on an image, or to reconstruct a high dynamic range (HDR) image. The second method improves on the first, bypassing the requirement for specific separation of diffuse and specular reflection components. For the latter method, diffuse and specular reflectance parameters are estimated separately, using the least squares method. Reflection values are initially assumed to be diffuse-only reflection components, and are subjected to the least squares method to estimate diffuse reflectance parameters. Specular reflection components, obtained by subtracting the computed diffuse reflection components from reflection values, are then subjected to a logarithmically transformed equation of the Torrance-Sparrow reflection model, and specular reflectance parameters for gloss intensity and surface roughness are finally estimated using the least squares method. Experiments were carried out using both methods, with simulation data at different saturation levels, generated according to the Lambert and Torrance-Sparrow reflection models, and the second method, with spectral images captured by an imaging spectrograph and a moving light source. Our results show that the second method can estimate the diffuse and specular reflectance parameters for colors, gloss intensity and surface roughness more accurately and faster than the first one, so that colors and gloss can be reproduced more efficiently for HDR imaging.

  20. Affective predictors of the severity and change in eating psychopathology in residential eating disorder treatment: The role of social anxiety.

    PubMed

    Smith, Kathryn E; Mason, Tyler B; Leonard, Rachel C; Wetterneck, Chad T; Smith, Brad E R; Farrell, Nicholas R; Riemann, Brad C

    2018-01-01

    Despite evidence documenting relationships between eating disorder (ED) psychopathology, depression, and anxiety, little is known regarding how social anxiety is related to ED symptoms in treatment. Therefore this study examined associations between depression, general anxiety, social anxiety, and ED psychopathology at the beginning and end of treatment (EOT) among patients (N = 380) treated in a residential ED program. Participants completed measures of ED psychopathology and affective variables. Higher depression and general anxiety, but not social anxiety, were related to higher ED psychopathology at baseline. However, social anxiety emerged as a unique predictor of ED psychopathology at EOT such that participants with higher social anxiety evidenced less improvement in ED psychopathology. Findings suggest that social anxiety has specific relevance to treatment in EDs, which may reflect shared mechanisms and underlying deficits in emotion regulation.

  1. Study on the effect of Cd-diffusion annealing on the electrical properties of CdZnTe

    NASA Astrophysics Data System (ADS)

    Wanwan, Li; Zechun, Cao; Bin, Zhang; Feng, Zhan; Hongtao, Liu; Wenbin, Sang; Jiahua, Min; Kang, Sun

    2006-06-01

    In order to meet the requirements for the device design of radiation detectors, CdZnTe (or Cd 1-xZn xTe) crystals grown by Vertical Bridgman Method often need subsequent annealing to increase their resistivity. The nature of this treatment is a diffusion process. Thus, it is meaningful to relate the change of resistivity to the diffusion parameters. A model correlating resistivity and conduction type of CdZnTe with the main diffusion parameter—diffusion coefficient—is put forward in this paper. Combining the model with the analysis of our experimental data, DCd=1.464×10 -10, 1.085×10 -11 and 4.167×10 -13 cm 2/s are the values of Cd self-diffusion coefficient in Cd 0.9Zn 0.1Te at 1073, 973 and 873 K, respectively. The data coincide closely with the Cd self-diffusion coefficient in CdTe provided by different authors [E.D. Jones, N.M. Stewart, Self-diffusion of cadmium in cadmium telluride, J. Crystal Growth 84 (1987) 289-294; P.M. Borsenberger, D.A. Stevenson, J. Phys. Chem. Solids 29 (1968) 1277; R.C. Whelan, D. Shaw, in: D.G. Thomas (Ed.), II -VI Semiconductor Compounds, Benjamin, New York, 1967, p. 451]. With the data, the effects of annealing time on the change of resistivity and conduction type for Cd 0.9Zn 0.1Te wafers, which are annealed in saturated Cd vapor at 1073, 973 and 873 K, were simulated, and good consistency was found. This work suggests an alternative way to obtain the diffusion coefficient in semiconductor materials and also enables ones to analyze the diffusion process quantitatively and predict the annealing results.

  2. Flux Growth of Highly Crystalline Photocatalytic BaTiO3 Particle Layers on Porous Titanium Sponge Substrate and Insights into the Formation Mechanism

    NASA Astrophysics Data System (ADS)

    Wang, Q.; Li, B.

    2017-09-01

    A unique architecture of idiomorphic and highly crystalline BaTiO3 particle layers directly grown on a porous titanium sponge substrate was successfully achieved for the first time using a facile molten salt method at a relatively low temperature of 700 °C. Specifically, the low-melting KCl-NaCl eutectic salts and barium hydroxide octahydrate were employed as the reaction medium and barium source, respectively. Powder X-ray diffraction (XRD), scanning electron microscopy (SEM), Energy dispersive X-ray spectroscopy (EDS), transmission electron microscopy (TEM), high-resolution transmission electron microscopy (HRTEM) and UV-vis diffuse reflectance spectrophotometry were used to characterize the structure, morphology and optical property of the obtained samples. The results revealed that the flux-grown tetragonal BaTiO3 products had well-defined and uniform morphology with an average size of 300 nm and a band gap of ∼3.16 eV. Based on XRD, EDS, SEM, and TEM, the possible formation mechanism responsible for the well-developed architecture of BaTiO3 particle layers was proposed and discussed. Furthermore, the photocatalytic activity of the flux-grown BaTiO3 products for organic pollutant degradation under simulated sunlight irradiation was also investigated.

  3. Effects of crystallization and dopant concentration on the emission behavior of TiO2:Eu nanophosphors

    PubMed Central

    2012-01-01

    Uniform, spherical-shaped TiO2:Eu nanoparticles with different doping concentrations have been synthesized through controlled hydrolysis of titanium tetrabutoxide under appropriate pH and temperature in the presence of EuCl3·6H2O. Through air annealing at 500°C for 2 h, the amorphous, as-grown nanoparticles could be converted to a pure anatase phase. The morphology, structural, and optical properties of the annealed nanostructures were studied using X-ray diffraction, scanning electron microscopy, energy-dispersive X-ray spectroscopy [EDS], and UV-Visible diffuse reflectance spectroscopy techniques. Optoelectronic behaviors of the nanostructures were studied using micro-Raman and photoluminescence [PL] spectroscopies at room temperature. EDS results confirmed a systematic increase of Eu content in the as-prepared samples with the increase of nominal europium content in the reaction solution. With the increasing dopant concentration, crystallinity and crystallite size of the titania particles decreased gradually. Incorporation of europium in the titania particles induced a structural deformation and a blueshift of their absorption edge. While the room-temperature PL emission of the as-grown samples is dominated by the 5D0 - 7Fj transition of Eu+3 ions, the emission intensity reduced drastically after thermal annealing due to outwards segregation of dopant ions. PMID:22214494

  4. Applications and Implications of Fractional Dynamics for Dielectric Relaxation

    NASA Astrophysics Data System (ADS)

    Hilfer, R.

    This article summarizes briefly the presentation given by the author at the NATO Advanced Research Workshop on "Broadband Dielectric Spectroscopy and its Advanced Technological Applications", held in Perpignan, France, in September 2011. The purpose of the invited presentation at the workshop was to review and summarize the basic theory of fractional dynamics (Hilfer, Phys Rev E 48:2466, 1993; Hilfer and Anton, Phys Rev E Rapid Commun 51:R848, 1995; Hilfer, Fractals 3(1):211, 1995; Hilfer, Chaos Solitons Fractals 5:1475, 1995; Hilfer, Fractals 3:549, 1995; Hilfer, Physica A 221:89, 1995; Hilfer, On fractional diffusion and its relation with continuous time random walks. In: Pekalski et al. (eds) Anomalous diffusion: from basis to applications. Springer, Berlin, p 77, 1999; Hilfer, Fractional evolution equations and irreversibility. In: Helbing et al. (eds) Traffic and granular flow'99. Springer, Berlin, p 215, 2000; Hilfer, Fractional time evolution. In: Hilfer (ed) Applications of fractional calculus in physics. World Scientific, Singapore, p 87, 2000; Hilfer, Remarks on fractional time. In: Castell and Ischebeck (eds) Time, quantum and information. Springer, Berlin, p 235, 2003; Hilfer, Physica A 329:35, 2003; Hilfer, Threefold introduction to fractional derivatives. In: Klages et al. (eds) Anomalous transport: foundations and applications. Wiley-VCH, Weinheim, pp 17-74, 2008; Hilfer, Foundations of fractional dynamics: a short account. In: Klafter et al. (eds) Fractional dynamics: recent advances. World Scientific, Singapore, p 207, 2011) and demonstrate its relevance and application to broadband dielectric spectroscopy (Hilfer, J Phys Condens Matter 14:2297, 2002; Hilfer, Chem Phys 284:399, 2002; Hilfer, Fractals 11:251, 2003; Hilfer et al., Fractional Calc Appl Anal 12:299, 2009). It was argued, that broadband dielectric spectroscopy might be useful to test effective field theories based on fractional dynamics.

  5. Angular distribution of diffuse reflectance from incoherent multiple scattering in turbid media.

    PubMed

    Gao, M; Huang, X; Yang, P; Kattawar, G W

    2013-08-20

    The angular distribution of diffuse reflection is elucidated with greater understanding by studying a homogeneous turbid medium. We modeled the medium as an infinite slab and studied the reflection dependence on the following three parameters: the incident direction, optical depth, and asymmetry factor. The diffuse reflection is produced by incoherent multiple scattering and is solved through radiative transfer theory. At large optical depths, the angular distribution of the diffuse reflection with small incident angles is similar to that of a Lambertian surface, but, with incident angles larger than 60°, the angular distributions have a prominent reflection peak around the specular reflection angle. These reflection peaks are found originating from the scattering within one transport mean free path in the top layer of the medium. The maximum reflection angles for different incident angles are analyzed and can characterize the structure of angular distributions for different asymmetry factors and optical depths. The properties of the angular distribution can be applied to more complex systems for a better understanding of diffuse reflection.

  6. Diagnostic accuracy and reproducibility of pleural and lung ultrasound in discriminating cardiogenic causes of acute dyspnea in the emergency department.

    PubMed

    Cibinel, Gian Alfonso; Casoli, Giovanna; Elia, Fabrizio; Padoan, Monica; Pivetta, Emanuele; Lupia, Enrico; Goffi, Alberto

    2012-02-01

    Dyspnea is a common symptom in patients admitted to the Emergency Department (ED), and discriminating between cardiogenic and non-cardiogenic dyspnea is often a clinical dilemma. The initial diagnostic work-up may be inaccurate in defining the etiology and the underlying pathophysiology. The aim of this study was to evaluate the diagnostic accuracy and reproducibility of pleural and lung ultrasound (PLUS), performed by emergency physicians at the time of a patient's initial evaluation in the ED, in identifying cardiac causes of acute dyspnea. Between February and July 2007, 56 patients presenting to the ED with acute dyspnea were prospectively enrolled in this study. In all patients, PLUS was performed by emergency physicians with the purpose of identifying the presence of diffuse alveolar-interstitial syndrome (AIS) or pleural effusion. All scans were later reviewed by two other emergency physicians, expert in PLUS and blinded to clinical parameters, who were the ultimate judges of positivity for diffuse AIS and pleural effusion. A random set of 80 recorded scannings were also reviewed by two inexperienced observers to assess inter-observer variability. The entire medical record was independently reviewed by two expert physicians (an emergency medicine physician and a cardiologist) blinded to the ultrasound (US) results, in order to determine whether, for each patient, dyspnea was due to heart failure, or not. Sensitivity, specificity, and positive/negative predictive values were obtained; likelihood ratio (LR) test was used. Cohen's kappa was used to assess inter-observer agreement. The presence of diffuse AIS was highly predictive for cardiogenic dyspnea (sensitivity 93.6%, specificity 84%, positive predictive value 87.9%, negative predictive value 91.3%). On the contrary, US detection of pleural effusion was not helpful in the differential diagnosis (sensitivity 83.9%, specificity 52%, positive predictive value 68.4%, negative predictive value 72.2%). Finally, the coexistence of diffuse AIS and pleural effusion is less accurate than diffuse AIS alone for cardiogenic dyspnea (sensitivity 81.5%, specificity 82.8%, positive predictive value 81.5%, negative predictive value 82.8%). The positive LR was 5.8 for AIS [95% confidence interval (CI) 4.8-7.1] and 1.7 (95% CI 1.2-2.6) for pleural effusion, negative LR resulted 0.1 (95% CI 0.0-0.4) for AIS and 0.3 (95% CI 0.1-0.8) for pleural effusion. Agreement between experienced and inexperienced operators was 92.2% (p < 0.01) and 95% (p < 0.01) for diagnosis of AIS and pleural effusion, respectively. In early evaluation of patients presenting to the ED with dyspnea, PLUS, performed with the purpose of identifying diffuse AIS, may represent an accurate and reproducible bedside tool in discriminating between cardiogenic and non-cardiogenic dyspnea. On the contrary, US detection of pleural effusions does not allow reliable discrimination between different causes of acute dyspnea in unselected ED patients.

  7. Bayesian Nonparametric Prediction and Statistical Inference

    DTIC Science & Technology

    1989-09-07

    Kadane, J. (1980), "Bayesian decision theory and the sim- plification of models," in Evaluation of Econometric Models, J. Kmenta and J. Ramsey , eds...the random model and weighted least squares regression," in Evaluation of Econometric Models, ed. by J. Kmenta and J. Ramsey , Academic Press, 197-217...likelihood function. On the other hand, H. Jeffreys’s theory of hypothesis testing covers the most important situations in which the prior is not diffuse. See

  8. Concentration-Encoded Subdiffusive Molecular Communication: Theory, Channel Characteristics, and Optimum Signal Detection.

    PubMed

    Mahfuz, Mohammad Upal; Makrakis, Dimitrios; Mouftah, Hussein T

    2016-09-01

    Unlike normal diffusion, in anomalous diffusion, the movement of a molecule is described by the correlated random walk model where the mean square displacement of a molecule depends on the power law of time. In molecular communication (MC), there are many scenarios when the propagation of molecules cannot be described by normal diffusion process, where anomalous diffusion is a better fit. In this paper, the effects of anomalous subdiffusion on concentration-encoded molecular communication (CEMC) are investigated. Although classical (i.e., normal) diffusion is a widely-used model of diffusion in molecular communication (MC) research, anomalous subdiffusion is quite common in biological media involving bio-nanomachines, yet inadequately addressed as a research issue so far. Using the fractional diffusion approach, the molecular propagation effects in the case of pure subdiffusion occurring in an unbounded three-dimensional propagation medium have been shown in detail in terms of temporal dispersion parameters of the impulse response of the subdiffusive channel. Correspondingly, the bit error rate (BER) performance of a CEMC system is investigated with sampling-based (SD) and strength (i.e., energy)-based (ED) signal detection methods. It is found that anomalous subdiffusion has distinctive time-dispersive properties that play a vital role in accurately designing a subdiffusive CEMC system. Unlike normal diffusion, to detect information symbols in subdiffusive CEMC, a receiver requires larger memory size to operate correctly and hence a more complex structure. An in-depth analysis has been made on the performances of SD and ED optimum receiver models under diffusion noise and intersymbol interference (ISI) scenarios when communication range, transmission data rate, and memory size vary. In subdiffusive CEMC, the SD method.

  9. Applicability of a Diffuse Reflectance Infrared Fourier Transform handheld spectrometer to perform in situ analyses on Cultural Heritage materials

    NASA Astrophysics Data System (ADS)

    Arrizabalaga, Iker; Gómez-Laserna, Olivia; Aramendia, Julene; Arana, Gorka; Madariaga, Juan Manuel

    2014-08-01

    This work studies the applicability of a Diffuse Reflectance Infrared Fourier Transform handheld device to perform in situ analyses on Cultural Heritage assets. This portable diffuse reflectance spectrometer has been used to characterise and diagnose the conservation state of (a) building materials of the Guevara Palace (15th century, Segura, Basque Country, Spain) and (b) different 19th century wallpapers manufactured by the Santa Isabel factory (Vitoria-Gasteiz, Basque Country, Spain) and by the well known Dufour and Leroy manufacturers (Paris, France), all of them belonging to the Torre de los Varona Castle (Villanañe, Basque Country, Spain). In all cases, in situ measurements were carried out and also a few samples were collected and measured in the laboratory by diffuse reflectance spectroscopy (DRIFT) in order to validate the information obtained by the handheld instrument. In the analyses performed in situ, distortions in the diffuse reflectance spectra can be observed due to the presence of specular reflection, showing the inverted bands caused by the Reststrahlen effect, in particular on those IR bands with the highest absorption coefficients. This paper concludes that the results obtained in situ by a diffuse reflectance handheld device are comparable to those obtained with laboratory diffuse reflectance spectroscopy equipment and proposes a few guidelines to acquire good spectra in the field, minimising the influence caused by the specular reflection.

  10. Electrodeposition of gold nanoparticles on mesoporous TiO{sub 2} photoelectrode to enhance visible region photocurrent

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Supriyono,; Krisnandi, Yuni Krisyuningsih; Gunlazuardi, Jarnuzi, E-mail: jarnuzi@ui.ac.id

    2016-04-19

    Electrodeposition of gold nanoparticles (Au NPs) on the mesoporous TiO{sub 2} photoelectrode to enchance visible region photocurrent have been investigated. Mesoporous TiO{sub 2} was prepared by a sol gel method and immobilized to the fluorine doped tin oxide (FTO) substrate by dip coating technique. Gold nanoparticles were electrodeposited on the TiO{sub 2} surface and the result FTO/TiO{sub 2}/Au was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), UV-Vis diffuse reflectance spectroscopy (DRS), and X-ray diffraction (XRD). The generated photocurrent was evaluated with an electrochemical workstation (e-DAQ/e-recorder 401) using 60 W wolfram lamp as visible lightmore » source. The photoelectrochemical evaluation indicated that the presence of gold nanoparticles on TiO{sub 2} photoelectrode shall enhance the photocurrent up to 50%.« less

  11. Improved backward ray tracing with stochastic sampling

    NASA Astrophysics Data System (ADS)

    Ryu, Seung Taek; Yoon, Kyung-Hyun

    1999-03-01

    This paper presents a new technique that enhances the diffuse interreflection with the concepts of backward ray tracing. In this research, we have modeled the diffuse rays with the following conditions. First, as the reflection from the diffuse surfaces occurs in all directions, it is impossible to trace all of the reflected rays. We confined the diffuse rays by sampling the spherical angle out of the reflected rays around the normal vector. Second, the traveled distance of reflected energy from the diffuse surface differs according to the object's property, and has a comparatively short reflection distance. Considering the fact that the rays created on the diffuse surfaces affect relatively small area, it is very inefficient to trace all of the sampled diffused rays. Therefore, we set a fixed distance as the critical distance and all the rays beyond this distance are ignored. The result of this research is that as the improved backward ray tracing can model the illumination effects such as the color bleeding effects, we can replace the radiosity algorithm under the limited environment.

  12. Transmitting and reflecting diffuser. [for ultraviolet light

    NASA Technical Reports Server (NTRS)

    Keafer, L. S., Jr.; Burcher, E. E.; Kopia, L. P. (Inventor)

    1973-01-01

    A near-Lambertian diffuser is described which transmits and reflects ultraviolet light. An ultraviolet grade fused silica substrate is coated with vaporized fuse silica. The coating thickness is controlled, one thickness causing ultraviolet light to diffuse and another thickness causing ultraviolet light to reflect a near Lambertian pattern.

  13. Differential color space analysis for investigating nutrient content in a puréed food dilution-flavor matrix: a step toward objective malnutrition risk assessment

    NASA Astrophysics Data System (ADS)

    Pfisterer, Kaylen J.; Amelard, Robert; Wong, Alexander

    2018-02-01

    Dysphagia (swallowing difficulty) increases risk for malnutrition and affects at least 15% of American older adults, and 590 million people worldwide. Malnutrition is associated with increased mortality, increased morbidity, decreased quality of life, and accounts for over $15 billion (USD) health-care related costs each year. While modified texture diets (e.g., puréed food) reduce the risk of choking, quality assurance is necessary for monitoring nutrient density to ensure food meets nutritional requirements. However, current methods are subjective and time consuming. The purpose of this study was to investigate the feasibility of optical techniques for an objective assessment of food nutrient density in puréed samples. Motivated by a theoretical optical dilution model, broadband spectral images of commercially prepared purée samples were acquired. Specifically, 13 flavors at five dilutions relative to initial concentration, each with six replicates, were acquired for a total of 390 samples. Purée samples were prepared and loaded onto a white reflectance back plane to maximize photon traversal path length through the purée. The sample was illuminated with a tungsten-halogen illumination source fitted with a front glass fabric diffuser for spatially homogeneous illumination. This broadband illuminant was chosen to observe as many food-light spectral absorbance interactions as possible. Flavor-stratified correlation analysis was performed on this food image dataset to investigate the relationship between nutritional information and color space transformations. A special case of blueberry is presented as the effect of anthocyanins was quantitatively observed through normalized spectral trends in response to pH perturbations across dilutions.

  14. Applicability of a Diffuse Reflectance Infrared Fourier Transform handheld spectrometer to perform in situ analyses on Cultural Heritage materials.

    PubMed

    Arrizabalaga, Iker; Gómez-Laserna, Olivia; Aramendia, Julene; Arana, Gorka; Madariaga, Juan Manuel

    2014-08-14

    This work studies the applicability of a Diffuse Reflectance Infrared Fourier Transform handheld device to perform in situ analyses on Cultural Heritage assets. This portable diffuse reflectance spectrometer has been used to characterise and diagnose the conservation state of (a) building materials of the Guevara Palace (15th century, Segura, Basque Country, Spain) and (b) different 19th century wallpapers manufactured by the Santa Isabel factory (Vitoria-Gasteiz, Basque Country, Spain) and by the well known Dufour and Leroy manufacturers (Paris, France), all of them belonging to the Torre de los Varona Castle (Villanañe, Basque Country, Spain). In all cases, in situ measurements were carried out and also a few samples were collected and measured in the laboratory by diffuse reflectance spectroscopy (DRIFT) in order to validate the information obtained by the handheld instrument. In the analyses performed in situ, distortions in the diffuse reflectance spectra can be observed due to the presence of specular reflection, showing the inverted bands caused by the Reststrahlen effect, in particular on those IR bands with the highest absorption coefficients. This paper concludes that the results obtained in situ by a diffuse reflectance handheld device are comparable to those obtained with laboratory diffuse reflectance spectroscopy equipment and proposes a few guidelines to acquire good spectra in the field, minimising the influence caused by the specular reflection. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Three-dimensional rotation electron diffraction: software RED for automated data collection and data processing

    PubMed Central

    Wan, Wei; Sun, Junliang; Su, Jie; Hovmöller, Sven; Zou, Xiaodong

    2013-01-01

    Implementation of a computer program package for automated collection and processing of rotation electron diffraction (RED) data is described. The software package contains two computer programs: RED data collection and RED data processing. The RED data collection program controls the transmission electron microscope and the camera. Electron beam tilts at a fine step (0.05–0.20°) are combined with goniometer tilts at a coarse step (2.0–3.0°) around a common tilt axis, which allows a fine relative tilt to be achieved between the electron beam and the crystal in a large tilt range. An electron diffraction (ED) frame is collected at each combination of beam tilt and goniometer tilt. The RED data processing program processes three-dimensional ED data generated by the RED data collection program or by other approaches. It includes shift correction of the ED frames, peak hunting for diffraction spots in individual ED frames and identification of these diffraction spots as reflections in three dimensions. Unit-cell parameters are determined from the positions of reflections in three-dimensional reciprocal space. All reflections are indexed, and finally a list with hkl indices and intensities is output. The data processing program also includes a visualizer to view and analyse three-dimensional reciprocal lattices reconstructed from the ED frames. Details of the implementation are described. Data collection and data processing with the software RED are demonstrated using a calcined zeolite sample, silicalite-1. The structure of the calcined silicalite-1, with 72 unique atoms, could be solved from the RED data by routine direct methods. PMID:24282334

  16. Three-dimensional rotation electron diffraction: software RED for automated data collection and data processing.

    PubMed

    Wan, Wei; Sun, Junliang; Su, Jie; Hovmöller, Sven; Zou, Xiaodong

    2013-12-01

    Implementation of a computer program package for automated collection and processing of rotation electron diffraction (RED) data is described. The software package contains two computer programs: RED data collection and RED data processing. The RED data collection program controls the transmission electron microscope and the camera. Electron beam tilts at a fine step (0.05-0.20°) are combined with goniometer tilts at a coarse step (2.0-3.0°) around a common tilt axis, which allows a fine relative tilt to be achieved between the electron beam and the crystal in a large tilt range. An electron diffraction (ED) frame is collected at each combination of beam tilt and goniometer tilt. The RED data processing program processes three-dimensional ED data generated by the RED data collection program or by other approaches. It includes shift correction of the ED frames, peak hunting for diffraction spots in individual ED frames and identification of these diffraction spots as reflections in three dimensions. Unit-cell parameters are determined from the positions of reflections in three-dimensional reciprocal space. All reflections are indexed, and finally a list with hkl indices and intensities is output. The data processing program also includes a visualizer to view and analyse three-dimensional reciprocal lattices reconstructed from the ED frames. Details of the implementation are described. Data collection and data processing with the software RED are demonstrated using a calcined zeolite sample, silicalite-1. The structure of the calcined silicalite-1, with 72 unique atoms, could be solved from the RED data by routine direct methods.

  17. Implementing reflection: insights from pre-registration mental health students.

    PubMed

    Donovan, Moira O

    2007-08-01

    Reflection and reflective practice continues to be contentious issues in nursing. The focus of this article is the use of reflection by pre-registration mental health students. The broad aim of this preliminary study was to discover student mental health nurses' perceptions of reflection as a learning strategy during clinical placement. Using a constructivist grounded theory methodology [Charmaz, K., 2000. Grounded theory: Objectivist and Constructivist Methods. In: Denzin, N., Lincoln, Y. (Eds.), Handbook of Qualitative Research, second ed. Sage, Thousand Oaks, California], five students were interviewed individually in their clinical placements. Data analysis revealed three major categories: understanding the process of reflection, using reflection in clinical practice, and needing support and guidance. Findings indicated that students were primarily using reflection-on-action, but to varying extents. Overall, students felt that reflection facilitated their learning. Factors were discovered that both helped and hindered students' use of reflection. These included level of preparation to reflect, a limited culture of reflection and the level of support from preceptors, clinical staff, clinical placement co-ordinators, and lecturers. In conclusion, it appears that a collaborative approach between students, Health Service Providers and institutes of nursing is vital for the successful development and implementation of reflective learning strategies in clinical placement. Suggestions are made as to how a collaborative approach may be developed to enhance this process.

  18. In-vivo Reflectance Measurements from Human Skin

    NASA Astrophysics Data System (ADS)

    Delgado, J. A.; Cornejo, A.; Cunill, M.; Báez, J. J.; Matos, R.; Anasagasti, L.; Santiago, C.

    2006-09-01

    We evaluate the potential of using a standard commercial spectrophotometer, specifically designed to meet the growing requirement for color control in the digital-imaging application field, to perform in-vivo diffuse reflectance measurements from adult human skin. We report and discuss diffuse reflectance spectra for three practical situations: a) reflectance versus skin type, b) reflectance from normal skin with different grade of solar exposition, c) reflectance from normal skin versus reflectance from seborrheic keratosis. Results show, that using the above spectrophotometer we can easily differentiate two sites of different solar exposition. Besides, significant differences are found in the normal skin diffuse reflectance for patients with different skin types.

  19. Assessing rumination in eating disorders: principal component analysis of a minimally modified ruminative response scale.

    PubMed

    Cowdrey, Felicity A; Park, Rebecca J

    2011-12-01

    A process account of eating disorders (EDs) (Park et al., in press-a) proposes that preoccupation with ruminative themes of eating, weight and shape may be important in ED maintenance. No self-report measure exists to capture disorder-specific rumination in EDs. 275 healthy participants rated rumination items and completed self-report measures of ED symptoms, depression and anxiety. Principal component analysis revealed two factors, reflection and brooding. The final nine-item Ruminative Response Scale for Eating Disorders (RRS-ED) demonstrated good convergent and discriminant validity and test-retest reliability. The psychometric properties were replicated in an anorexia nervosa sample. The findings support the notion that rumination in EDs is distinct from rumination in depression and is not adequately captured by existing measures. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Diffuse reflectance spectroscopy of pre- and post-treated oral submucous fibrosis: an in vivo study

    NASA Astrophysics Data System (ADS)

    Sivabalan, S.; Ponranjini Vedeswari, C.; Jayachandran, S.; Koteeswaran, D.; Pravda, C.; Aruna, P.; Ganesan, S.

    2010-02-01

    Oral submucous fibrosis (OSF) is a high risk precancerous condition characterized by changes in the connective tissue fibers of the lamina propria and deeper parts leading to stiffness of the mucosa and restricted mouth opening, fibrosis of the lining mucosa of the upper digestive tract involving the oral cavity, oro- and hypo-pharynx and the upper two-thirds of the oesophagus. Optical reflectance measurements have been used to extract diagnostic information from a variety of tissue types, in vivo. We apply diffuse reflectance spectroscopy to quantitatively monitor tumour response to chemotherapy. Twenty patients with submucous fibrosis were diagnosed with diffuse reflectance spectroscopy and treated with the chemotherapy drug, Dexamethasone sodium phosphate and Hyaluronidase injection for seven weeks and after the treatment they were again subjected to the diffuse reflectance spectroscopy. The major observed spectral alterations on pre and post treated submucous fibrosis is an increase in the diffuse reflectance from 450 to 600 nm. Normal mucosa has showed higher reflectance when compared to the pre and post-treated cases. The spectral changes were quantified and correlated to conventional diagnostic results viz., maximum mouth opening, tongue protrusion and burning sensation. The results of this study suggest that the diffuse reflectance spectroscopy may also be considered as complementary optical techniques to monitor oral tissue transformation.

  1. Influence of diffuse reflectance measurement accuracy on the scattering coefficient in determination of optical properties with integrating sphere optics (a secondary publication).

    PubMed

    Horibe, Takuro; Ishii, Katsunori; Fukutomi, Daichi; Awazu, Kunio

    2015-12-30

    An estimation error of the scattering coefficient of hemoglobin in the high absorption wavelength range has been observed in optical property calculations of blood-rich tissues. In this study, the relationship between the accuracy of diffuse reflectance measurement in the integrating sphere and calculated scattering coefficient was evaluated with a system to calculate optical properties combined with an integrating sphere setup and the inverse Monte Carlo simulation. Diffuse reflectance was measured with the integrating sphere using a small incident port diameter and optical properties were calculated. As a result, the estimation error of the scattering coefficient was improved by accurate measurement of diffuse reflectance. In the high absorption wavelength range, the accuracy of diffuse reflectance measurement has an effect on the calculated scattering coefficient.

  2. Does active dissemination of evidence result in faster knowledge transfer than passive diffusion?: An analysis of trends of the management of pediatric asthma and croup in US emergency departments from 1995 to 2009.

    PubMed

    Knapp, Jane F; Simon, Stephen D; Sharma, Vidya

    2015-03-01

    This study aimed to compare knowledge transfer (KT) in the emergency department (ED) management of pediatric asthma and croup by measuring trends in corticosteroid use for both conditions in EDs. A retrospective, cross-sectional study of the National Hospital Ambulatory Medical Care Survey data between 1995 and 2009 of corticosteroid use at ED visits for asthma or croup was conducted. Odds ratios (OR) were calculated using logistic regression. Trends over time were compared using an interaction term between disease and year and were adjusted for all other covariates in the model. We included children aged 2 to 18 years with asthma who received albuterol and were triaged emergent/urgent. Children aged between 3 months to 6 years with croup were included. The main outcome measure was the administration of corticosteroids in the ED or as a prescription at the ED visit. The corticosteroid use in asthma visits increased from 44% to 67% and from 32% to 56% for croup. After adjusting for patient and hospital factors, this trend was significant both for asthma (OR, 1.07; 95% confidence interval [CI], 1.04-1.10) and croup (OR, 1.07; 95% CI, 1.03-1.12). There was no statistical difference between the 2 trends (P = 0.69). Hospital location in a metropolitan statistical area was associated with increased corticosteroid use in asthma (OR, 1.76; 95% CI, 1.10-2.82). Factors including sex, ethnicity, insurance, or region of the country were not significantly associated with corticosteroid use. During a 15-year period, knowledge transfer by passive diffusion or active guideline dissemination resulted in similar trends of corticosteroid use for the management of pediatric asthma and croup.

  3. Task-shifting Using a Pain Management Protocol in an Emergency Care Service: Nurses' Perception through the Eye of the Rogers's Diffusion of Innovation Theory.

    PubMed

    Hadorn, Fabienne; Comte, Pascal; Foucault, Eliane; Morin, Diane; Hugli, Olivier

    2016-02-01

    It has been shown that over 70% of patients waiting in emergency departments (EDs) do not receive analgesics, despite the fact that more than 78% complain of pain. A clinical innovation in the form of a pain management protocol that includes task-shifting has been implemented in the ED of a university hospital in Switzerland in order to improve pain-related outcomes in patients. This innovation involves a change in clinical practice for physicians and nurses. The aim of this study is to explore nurses' perceptions on how well this innovation is adopted. This descriptive correlational study took place in the ED of a Swiss university hospital; the hospital provides healthcare for the city, the canton, and adjoining cantons. A convenience sample of 37 ED nurses participated. They were asked to complete a questionnaire comprising 56 statements based on Rogers's "Diffusion of Innovation" theory. Nurses' opinions (on a 1-10 Likert scale) indicate that the new protocol benefits the ED (mean [M] = 7.4, standard deviation [SD] = 1.21), is compatible with nursing roles (M = 8.0, SD = 1.9), is not too complicated to apply (M = 2.7, SD = 1.7), provides observable positive effects in patients (M = 7.0, SD = 1.28), and is relatively easy to introduce into daily practice (M = 6.5, SD = 1.0). Further studies are now needed to examine patients' experiences of this innovation. Copyright © 2016 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.

  4. Breakers, Benders, and Obeyers: Inquiring into Teacher Educators' Mediation of edTPA

    ERIC Educational Resources Information Center

    Ratner, Andrew R.; Kolman, Joni S.

    2016-01-01

    This article reflects a qualitative exploratory inquiry into the lived experiences of faculty members working within a system of urban schools of education as they supported diverse teacher candidates in completing the Educative Teacher Performance Assessment (edTPA) during its first semesters of high-stakes implementation. Drawing upon…

  5. COIN Goes GLOCAL: Traditional COIN With a Global Perspective: Does the Current US Strategy Reflect COIN Theory, Doctrine and Principles

    DTIC Science & Technology

    2007-05-17

    Fighting a Global Insurgency” in Parameters Summer 2006. Beckett , Ian F. W., [ed.]. The Roots of Counter-Insurgency : Armies and Guerrilla Warfare...Scranton, Phil (ed.). Beyond September 11: An Anthology of Dissent. London: Pluto Press, 2002. Sepp, Kalev I., “Best Practices in

  6. Applications of fourier transform infrared spectroscopy to surface analysis problems 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Powell, G.L.; Milosevic, M.

    Applications of infrared spectroscopy to surface analysis are described in terms of the combined use of a number of techniques to solve specific surface analysis problems involving both qualitative and quantitative analysis of surface species. Emphasis is placed on the characterization of both the substrate and the surface species and the application of this to the monitoring of surface processes and the inspection of manufactured items. Lithium Hydride has been studied using remote analysis by diffuse reflectance in glove boxes containing very pure argon or controlled moisture levels with robot-operated gravimetric monitoring. These experiments are supported by internal reflectance andmore » diffuse reflectance measurements in spectrometer sample compartments to characterize the reactants. Beryllium oxide has been studied using an evacuable diffuse reflectance cell to determine the effects of vacuum baking reexposure to moisture on the surface hydroxyl species. Diffuse reflectance and emission measurements have been used to monitor the curing and reaction of environmental gases with composite materials such as graphite-expoxy structures. A direct comparison of diffuse reflectance and emission spectra was done using a barrel ellipsoid diffuse reflectance/emission detector and Spectropus optical transfer system. Grazing-incidence external-reflectance with p-polarized light was used to study the oxidation in room air of polished uranium coupons. The absorption band at 570 cm{sup {minus}1} was used to monitor the extent of oxidation with a resolution of approximately one monolayer of UO{sub 2} and to distinguish the parabolic, linear, and breakaway corrosion domains. External reflectance is compared with diffuse reflectance as a method for stain analysis and for measuring the effects of H{sub 2}O in UO{sub 2} corrosion films.« less

  7. Applications of fourier transform infrared spectroscopy to surface analysis problems 2. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Powell, G.L.; Milosevic, M.

    Applications of infrared spectroscopy to surface analysis are described in terms of the combined use of a number of techniques to solve specific surface analysis problems involving both qualitative and quantitative analysis of surface species. Emphasis is placed on the characterization of both the substrate and the surface species and the application of this to the monitoring of surface processes and the inspection of manufactured items. Lithium Hydride has been studied using remote analysis by diffuse reflectance in glove boxes containing very pure argon or controlled moisture levels with robot-operated gravimetric monitoring. These experiments are supported by internal reflectance andmore » diffuse reflectance measurements in spectrometer sample compartments to characterize the reactants. Beryllium oxide has been studied using an evacuable diffuse reflectance cell to determine the effects of vacuum baking reexposure to moisture on the surface hydroxyl species. Diffuse reflectance and emission measurements have been used to monitor the curing and reaction of environmental gases with composite materials such as graphite-expoxy structures. A direct comparison of diffuse reflectance and emission spectra was done using a barrel ellipsoid diffuse reflectance/emission detector and Spectropus optical transfer system. Grazing-incidence external-reflectance with p-polarized light was used to study the oxidation in room air of polished uranium coupons. The absorption band at 570 cm{sup {minus}1} was used to monitor the extent of oxidation with a resolution of approximately one monolayer of UO{sub 2} and to distinguish the parabolic, linear, and breakaway corrosion domains. External reflectance is compared with diffuse reflectance as a method for stain analysis and for measuring the effects of H{sub 2}O in UO{sub 2} corrosion films.« less

  8. Structural analysis of reactionary dentin formed in response to polymicrobial invasion

    PubMed Central

    Charadram, Nattida; Austin, Christine; Trimby, Patrick; Simonian, Mary; Swain, Michael V.; Hunter, Neil

    2013-01-01

    In response to microbial invasion of dentin odontoblasts secrete an altered calcified matrix termed reactionary dentin (Rd). 3D reconstruction of focused-ion-beam scanning electron microscopy (FIB-SEM) image slices revealed helical tubular structures in Rd that contrasted with regular cylindrical tubules characteristic of dentin from healthy teeth and affected so-called physiological dentin (Pd) lying exterior to Rd. This helical structure in Rd provided effective constriction of tubule lumen diameter that formed a barrier to bacterial advance towards the dental pulp. SEM of resin cast preparations revealed altered extension of odontoblast processes through Rd. The distribution of key mineral elements was studied by combination of 3D reconstruction of focused-ion-beam based X-ray microanalysis (FIB-EDS), laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS). There was a marked redistribution of calcium and phosphorous in Rd together with an increase of diffusely deposited magnesium compatible with the mineral deposition phase of synthesis of this altered matrix. Changes in tubule structure and mineral content characteristic of Rd are consistent with reduced hardness and lower elastic modulus reported for this matrix. Findings provide insight into the unique structure of Rd synthesised as a primary response to infection. PMID:23261402

  9. Cooperativity in Molecular Dynamics Structural Models and the Dielectric Spectra of 1,2-Ethanediol

    NASA Astrophysics Data System (ADS)

    Usacheva, T. M.

    2018-05-01

    Linear relationships are established between the experimental equilibrium correlation factor and the molecular dynamics (MD) mean value of the O-H···O bond angle and the longitudinal component of the unit vector of the mean statistical dipole moment of the cluster in liquid 1,2-ethanediol (12ED). The achievements of modern MD models in describing the experimental dispersion of the permittivity of 12ED by both continuous and discrete relaxation time spectra are analyzed. The advantage computer MD experiments have over dielectric spectroscopy for calculating relaxation time and determining the molecular diffusion mechanisms of the rearrangement of the network 12ED structure, which is more complex than water, is demonstrated.

  10. [Prevalence of patients with HIV infection in an emergency department].

    PubMed

    Greco, G M; Paparo, R; Ventura, R; Migliardi, C; Tallone, R; Moccia, F

    1995-01-01

    The activity at an ED, primarily aiming at providing rational and qualified support to critically ill patients, is forced to manage very different nosographic entities, including infectious, often contagious, pathologies. In this context the diffusion of HIV infection poses a number of problems concerning both the kind of patients presenting to the ED and the professional risk of health-care workers. In the first four months of 1992 the incidence of patients with recognized or presumed HIV infection at the "Pronto Soccorso Medico" was of 1.78% of 2327 patients admitted. This study aims to contribute to the epidemiologic definition of the risk of HIV infection due to occupational exposure, stressing the peculiar conditions of urgency-emergency often characterizing the activity within the ED.

  11. Predictors of cerebral microembolization during phased radiofrequency ablation of atrial fibrillation: role of the ongoing rhythm and the site of energy delivery.

    PubMed

    Nagy-Balo, Edina; Kiss, Alexandra; Condie, Catherine; Stewart, Mark; Edes, Istvan; Csanadi, Zoltan

    2014-11-01

    Pulmonary vein isolation with phased radiofrequency current and use of a pulmonary vein ablation catheter (PVAC) has recently been associated with a high incidence of clinically silent brain infarcts on diffusion-weighted magnetic resonance imaging, and a high microembolic signal (MES) count detected by transcranial Doppler. We investigated the potential effects of the ongoing rhythm and the target vein during energy delivery (ED) on MES generation during PVAC ablations. A total of 735 EDs during 48 PVAC ablations were analyzed. MES counts were recorded for each ED and time-stamped for correlation with the ongoing rhythm and the target vein for each ED. Significantly higher MES counts were observed during ablations of the left-sided as compared with the right-sided pulmonary veins (P = 0.0003). Similarly, higher MES counts were detected during EDs in atrial fibrillation as compared with sinus rhythm when the temperature was >56°C (P < 0.0001). The ongoing rhythm had no effect on the number of MESs at lower temperatures during ablation. Both the ongoing rhythm during ED and the site of ablation influence microembolus generation during PVAC ablation procedures. ©2014 Wiley Periodicals, Inc.

  12. Reduction of skylight reflection effects in the above-water measurement of diffuse marine reflectance.

    PubMed

    Fougnie, B; Frouin, R; Lecomte, P; Deschamps, P Y

    1999-06-20

    Reflected skylight in above-water measurements of diffuse marine reflectance can be reduced substantially by viewing the surface through an analyzer transmitting the vertically polarized component of incident radiance. For maximum reduction of effects, radiometric measurements should be made at a viewing zenith angle of approximately 45 degrees (near the Brewster angle) and a relative azimuth angle between solar and viewing directions greater than 90 degrees (backscattering), preferably 135 degrees. In this case the residual reflected skylight in the polarized signal exhibits minimum sensitivity to the sea state and can be corrected to within a few 10(-4) in reflectance units. For most oceanic waters the resulting relative error on the diffuse marine reflectance in the blue and green is less than 1%. Since the water body polarizes incident skylight, the measured polarized reflectance differs from the total reflectance. The difference, however, is small for the considered geometry. Measurements made at the Scripps Institution of Oceanography pier in La Jolla, Calif., with a specifically designed scanning polarization radiometer, confirm the theoretical findings and demonstrate the usefulness of polarization radiometry for measuring diffuse marine reflectance.

  13. Structural Investigations of Fibers and Films of Poly(p-phenylene benzobisthiazole). Volume 1

    DTIC Science & Technology

    1982-05-01

    differential scanning calorimetry, is unrelated to the diffuse scattered intensity [45]. Cellulose acetate which is known to be noncrystalline exhibits a high...Weidinger [45] found the diffuse scattered intensity increased with decreasing density and therefore, increasing void fraction, in air swollen cellulose ... Cellulose , and Poly(y-Benzyl-L-Glutamate)." J. Polym. Sci., Polym. Phys. Ed., 18, 663-682 (1980). 39. C.H. Kao and J.M. Ottino, personal communication

  14. Using Ontological Engineering to Overcome AI-ED Problems: Contribution, Impact and Perspectives

    ERIC Educational Resources Information Center

    Mizoguchi, Riichiro; Bourdeau, Jacqueline

    2016-01-01

    This article reflects on the ontology engineering methodology discussed by the paper entitled "Using Ontological Engineering to Overcome AI-ED Problems" published in this journal in 2000. We discuss the achievements obtained in the last 10 years, the impact of our work as well as recent trends and perspectives in ontology engineering for…

  15. Growth Mechanism Studies of ZnO Nanowires: Experimental Observations and Short-Circuit Diffusion Analysis.

    PubMed

    Shih, Po-Hsun; Wu, Sheng Yun

    2017-07-21

    Plenty of studies have been performed to probe the diverse properties of ZnO nanowires, but only a few have focused on the physical properties of a single nanowire since analyzing the growth mechanism along a single nanowire is difficult. In this study, a single ZnO nanowire was synthesized using a Ti-assisted chemical vapor deposition (CVD) method to avoid the appearance of catalytic contamination. Two-dimensional energy dispersive spectroscopy (EDS) mapping with a diffusion model was used to obtain the diffusion length and the activation energy ratio. The ratio value is close to 0.3, revealing that the growth of ZnO nanowires was attributed to the short-circuit diffusion.

  16. Anorexia and bulimia nervosa: virtual diffusion of the disease as a lifestyle

    PubMed

    Lladó, Gina; González-Soltero, Rocío; Blanco Fernández de Valderrama, María José

    2017-06-05

    Introduction: Adolescence is a vulnerable period for the onset of eating disorders (ED) such as anorexia and bulimia nervosas. Body dissatisfaction, a precipitating factor for ED, leads adolescents to seek information on the Internet about diets. In this context, pro-Ana (proanorexia) and pro-Mia (probulimia) are on-line pages that promulgate highly harmful contents for health related to weight loss and ED. Objectives: The aim of this study was to analyze quantity, quality and social diffusion strategies used by pro-Ana and pro-Mia webpages. Methods: A web search was done in the Google Chrome browser, using the keywords “anorexia”, “bulimia”, “eating disorders”, “Ana and Mia”, “pro-Ana and pro-Mia”, “anorexic nation”, “obesity”, “healthy lifestyles” and “healthy nutrition”. The top 20 results for each search were selected and analyzed according to positioning rates (PageRank, PR). The quality of these resources was analyzed by a previously published questionnaire. Finally, a study of the diffusion in social networks like Facebook and Twitter was performed for pro-Ana and pro-Mia pages using SharedCount. Results: Searches for pro-Ana and pro-Mia reported more than a million entries. The pages were poorly positioned. Blog contents were the most shared between all the analyzed pages. Conclusions: pro-Ana and pro-Mia are resources with a clear intention to establish a contact with people with an eating disorder or who are at risk for developing one, in order to strengthen the communication through the blogosphere.

  17. Methods for quantitative infrared directional-hemispherical and diffuse reflectance measurements using an FTIR and a commercial integrating sphere

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blake, Thomas A.; Johnson, Timothy J.; Tonkyn, Russell G.

    Infrared integrating sphere measurements of solid samples are important in providing reference data for contact, standoff and remote sensing applications. At the Pacific Northwest National Laboratory (PNNL) we have developed protocols to measure both the directional-hemispherical ( and diffuse (d) reflectances of powders, liquids, and disks of powders and solid materials using a commercially available, matte gold-coated integrating sphere and Fourier transform infrared spectrometer. Detailed descriptions of the sphere alignment and its use for making these reflectance measurements are given. Diffuse reflectance values were found to be dependent on the bidirectional reflection distribution function (BRDF) of the sample and themore » solid angle intercepted by the sphere’s specular exclusion port. To determine how well the sphere and protocols produce quantitative reflectance data, measurements were made of three diffuse and two specular standards prepared by the National institute of Standards and Technology (NIST, USA), LabSphere Infragold and Spectralon standards, hand-loaded sulfur and talc powder samples, and water. The five NIST standards behaved as expected: the three diffuse standards had a high degree of “diffuseness,” d/ = D > 0.9, whereas the two specular standards had D ≤ 0.03. The average absolute differences between the NIST and PNNL measurements of the NIST standards for both directional-hemispherical and diffuse reflectances are on the order of 0.01 reflectance units. Other quantitative differences between the PNNL-measured and calibration (where available) or literature reflectance values for these standards and materials are given and the possible origins of discrepancies are discussed. Random uncertainties and estimates of systematic uncertainties are presented. Corrections necessary to provide better agreement between the PNNL reflectance values as measured for the NIST standards and the NIST reflectance values for these same standards are also discussed.« less

  18. Uranium migration in spark plasma sintered W/UO2 CERMETS

    NASA Astrophysics Data System (ADS)

    Tucker, Dennis S.; Wu, Yaqiao; Burns, Jatuporn

    2018-03-01

    W/UO2 CERMET samples were sintered in a Spark Plasma Sintering (SPS) furnace at various temperature under vacuum and pressure. High Resolution Transmission Electron Microscopy (HRTEM) with Energy Dispersive Spectroscopy (EDS) was performed on the samples to determine interface structures and uranium diffusion from the UO2 particles into the tungsten matrix. Local Electrode Atom Probe (LEAP) was also performed to determine stoichiometry of the UO2 particles. It was seen that uranium diffused approximately 10-15 nm into the tungsten matrix. This is explained in terms of production of oxygen vacancies and Fick's law of diffusion.

  19. Special report, diffuse reflectivity of the lunar surface

    NASA Technical Reports Server (NTRS)

    Fastie, W. G.

    1972-01-01

    The far ultraviolet diffuse reflectivity of samples of lunar dust material is determined. Equipment for measuring the diffuse reflectivity of materials (e.g. paint samples) is already in existence and requires only minor modification for the proposed experiment which will include the measurement of the polarizing properties of the lunar samples. Measurements can be made as a function of both illumination angle and angle of observation.

  20. [Application of BaSO4 diffuser plate in 250-400 nm spectral radiance calibration].

    PubMed

    Jia, Hui; Li, Fu-tian

    2004-01-01

    Sprayed BaSO4 diffuser plate is the most Lambertian surface actually used in spectral radiance calibration known by now. Its hemispheric reflectance and Bi-directional Reflectance Distribution Functions (BRDF) were measured in the experiment. Its diffuse characteristics were compared with Lambertian surface. In order to calibrate spectral radiance more accurately, the small variation of diffuser's BRDF with scattered angles and the nonuniformity of spectral irradiance on diffuser surface illuminated by the standard lamp should be considered. By integrating the radiation flux reflected by the element area and that entering the entrance slit within the viewing area of spectrometer, the measured spectral radiance can be calculated. Furthermore, the spectral radiance of Lambertian surface whose BRDF was derived from hemispheric reflectance was compared with that from the average of the measured BRDF.

  1. Diffuse and specular characteristics of leaf reflectance

    NASA Technical Reports Server (NTRS)

    Grant, Lois

    1987-01-01

    In this paper, the evolution of current understanding of the mechanisms of leaf reflectance is reviewed. The use of measurements of polarized reflectance to separate leaf reflectance into diffuse and specular components is discussed. A section on the factors influencing leaf reflectance - leaf structure and physiological disturbances - is included along with discussion on the manner in which these influences are manifested.

  2. Modeling Suomi-NPP VIIRS Solar Diffuser Degradation due to Space Radiation

    NASA Astrophysics Data System (ADS)

    Shao, X.; Cao, C.

    2014-12-01

    The Visible Infrared Imaging Radiometer Suite (VIIRS) onboard Suomi-NPP uses a solar diffuser (SD) as on-board radiometric calibrator for the reflective solar band (RSB) calibration. Solar diffuser is made of Spectralon (one type of fluoropolymer) and was chosen because of its controlled reflectance in the VIS-NIR-SWIR region and its near-Lambertian reflectance profile. Spectralon is known to degrade in reflectance at the blue end of the spectrum due to exposure to space radiations such as solar UV radiation and energetic protons. These space radiations can modify the Spectralon surface through breaking C-C and C-F bonds and scissioning or cross linking the polymer, which causes the surface roughness and degrades its reflectance. VIIRS uses a SDSM (Solar Diffuser Stability Monitor) to monitor the change in the Solar Diffuser reflectance in the 0.4 - 0.94 um wavelength range and provide a correction to the calibration constants. The H factor derived from SDSM reveals that reflectance of 0.4 to 0.6um channels of VIIRS degrades faster than the reflectance of longer wavelength RSB channels. A model is developed to derive characteristic parameters such as mean SD surface roughness height and autocovariance length of SD surface roughness from the long term spectral degradation of SD reflectance as monitored by SDSM. These two parameters are trended to assess development of surface roughness of the SD over the operation period of VIIRS.

  3. Contamination and UV ageing of diffuser targets used in satellite inflight and ground reference test site calibrations

    NASA Astrophysics Data System (ADS)

    Vaskuri, Anna; Greenwell, Claire; Hessey, Isabel; Tompkins, Jordan; Woolliams, Emma

    2018-02-01

    Diffuser reflectance targets are key components in in-orbit calibrations and for verifying ground reference test sites. In this work, Spectralon, Diffusil, and Heraeus diffusers were exposed to exhaust gases and ultraviolet (UV) radiation in the ambient air conditions and their degradations were monitored by measuring changes in spectral reflectances. Spectralon is a state-of-the-art diffuser made of polytetrafluoroethylene, and Diffusil and Heraeus diffusers are made of fused silica with gas bubbles inside. Based on the contamination tests, Spectralon degrades faster than fused silica diffusers. For the samples exposed to contamination for 20 minutes, the 250 nm - 400 nm total diffuse spectral reflectance of Spectralon degraded 3-5 times more when exposed to petrol-like emission and 16-23 times more when exposed to diesel-like emission, compared with Diffusil. When the reflectance changes of Spectralon were compared with those of Heraeus, Spectralon degraded 3-4 times more when exposed to petrol-like emission for 20 minutes and 5-7 times more when exposed to diesel-like emission for 7.5 minutes. When the samples contaminated were exposed to UV radiation in the ambient air, their reflectance gradually restored back to the original level. In conclusion, fused silica diffusers are more resistant to hydrocarbon contaminants present in ground reference test sites, and thus more stable under UV radiation in the air.

  4. In vivo assessment of liver fibrosis using diffuse reflectance and fluorescence spectroscopy: a proof of concept.

    PubMed

    Fabila, Diego; de la Rosa, José Manuel; Stolik, Suren; Moreno, Edgard; Suárez-Álvarez, Karina; López-Navarrete, Giuliana; Guzmán, Carolina; Aguirre-García, Jesús; Acevedo-García, Christian; Kershenobich, David; Escobedo, Galileo

    2012-12-01

    A novel application of diffuse reflectance and fluorescence spectroscopy in the assessment of liver fibrosis is here reported. To induce different stages of liver fibrosis, a sufficient number of male Wistar rats were differentially exposed to chronic administration with carbon tetrachloride. Then, diffuse reflectance and fluorescence spectra were in vivo measured from the liver surface of each animal by a minimal invasive laparoscopic procedure. The liver fibrosis degree was conventionally determined by means of histological examination using the Mason's Trichrome stain, accompanied by hepatic expression of α-sma, and evaluation of the ALT/AST serum levels. The liver from rats exhibiting higher grades of fibrosis showed a significant increase in diffuse reflectance and fluorescence intensity when compared with control animals. At 365 nm, the diffuse reflectance spectrum exhibited an increase of 4 and 3-fold in mild and advanced fibrotic rats, respectively, when compared to the control group. Similarly, the fluorescence emission at 493 nm was 2-fold higher in fibrotic animals than in controls. By using fluorescence intensity, discrimination algorithms indicated 73% sensitivity and 94% specificity for recognition of hepatic fibrosis, while for diffuse reflectance, these values increased up to 85% and 100%, respectively. Taking into consideration there is a special need for developing new diagnostic approaches focused on detecting different stages of liver fibrosis with minimal invasiveness, these results suggest that diffuse reflectance and fluorescence spectroscopy could be worthy of further exploration in patients with liver disease. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. The angular distribution of diffusely backscattered light

    NASA Astrophysics Data System (ADS)

    Vera, M. U.; Durian, D. J.

    1997-03-01

    The diffusion approximation predicts the angular distribution of light diffusely transmitted through an opaque slab to depend only on boundary reflectivity, independent of scattering anisotropy, and this has been verified by experiment(M.U. Vera and D.J. Durian, Phys. Rev. E 53) 3215 (1996). Here, by contrast, we demonstrate that the angular distribution of diffusely backscattered light depends on scattering anisotropy as well as boundary reflectivity. To model this observation scattering anisotropy is added to the diffusion approximation by a discontinuity in the photon concentration at the source point that is proportional to the average cosine of the scattering angle. We compare the resulting predictions with random walk simulations and with measurements of diffusely backscattered intensity versus angle for glass frits and aqueous suspensions of polystyrene spheres held in air or immersed in a water bath. Increasing anisotropy and boundary reflectivity each tend to flatten the predicted distributions, and for different combinations of anisotropy and reflectivity the agreement between data and predictions ranges from qualitatively to quantitatively good.

  6. Vacuum ultraviolet photolysis of hydrogenated amorphous carbons. III. Diffusion of photo-produced H2 as a function of temperature

    NASA Astrophysics Data System (ADS)

    Martín-Doménech, R.; Dartois, E.; Muñoz Caro, G. M.

    2016-06-01

    Context. Hydrogenated amorphous carbon (a-C:H) has been proposed as one of the carbonaceous solids detected in the interstellar medium. Energetic processing of the a-C:H particles leads to the dissociation of the C-H bonds and the formation of hydrogen molecules and small hydrocarbons. Photo-produced H2 molecules in the bulk of the dust particles can diffuse out to the gas phase and contribute to the total H2 abundance. Aims: We have simulated this process in the laboratory with plasma-produced a-C:H and a-C:D analogs under astrophysically relevant conditions to investigate the dependence of the diffusion as a function of temperature. Methods: Experimental simulations were performed in a high-vacuum chamber, with complementary experiments carried out in an ultra-high-vacuum chamber. Plasma-produced a-C:H and a-C:D analogs were UV-irradiated using a microwave-discharged hydrogen flow lamp. Molecules diffusing to the gas-phase were detected by a quadrupole mass spectrometer, providing a measurement of the outgoing H2 or D2 flux. By comparing the experimental measurements with the expected flux from a one-dimensional diffusion model, a diffusion coefficient D could be derived for experiments carried out at different temperatures. Results: Dependence on the diffusion coefficient D with the temperature followed an Arrhenius-type equation. The activation energy for the diffusion process was estimated (ED(H2) = 1660 ± 110 K, ED(D2) = 2090 ± 90 K), as well as the pre-exponential factor (D0(H2) = 0.0007 cm2 s-1, D0(D2) = 0.0045 cm2 s-1). Conclusions: The strong decrease of the diffusion coefficient at low dust particle temperatures exponentially increases the diffusion times in astrophysical environments. Therefore, transient dust heating by cosmic rays needs to be invoked for the release of the photo-produced H2 molecules in cold photon-dominated regions, where destruction of the aliphatic component in hydrogenated amorphous carbons most probably takes place.

  7. Design and evaluation of an imaging spectrophotometer incorporating a uniform light source.

    PubMed

    Noble, S D; Brown, R B; Crowe, T G

    2012-03-01

    Accounting for light that is diffusely scattered from a surface is one of the practical challenges in reflectance measurement. Integrating spheres are commonly used for this purpose in point measurements of reflectance and transmittance. This solution is not directly applicable to a spectral imaging application for which diffuse reflectance measurements are desired. In this paper, an imaging spectrophotometer design is presented that employs a uniform light source to provide diffuse illumination. This creates the inverse measurement geometry to the directional illumination/diffuse reflectance mode typically used for point measurements. The final system had a spectral range between 400 and 1000 nm with a 5.2 nm resolution, a field of view of approximately 0.5 m by 0.5 m, and millimeter spatial resolution. Testing results indicate illumination uniformity typically exceeding 95% and reflectance precision better than 1.7%.

  8. Including scattering within the room acoustics diffusion model: An analytical approach.

    PubMed

    Foy, Cédric; Picaut, Judicaël; Valeau, Vincent

    2016-10-01

    Over the last 20 years, a statistical acoustic model has been developed to predict the reverberant sound field in buildings. This model is based on the assumption that the propagation of the reverberant sound field follows a transport process and, as an approximation, a diffusion process that can be easily solved numerically. This model, initially designed and validated for rooms with purely diffuse reflections, is extended in the present study to mixed reflections, with a proportion of specular and diffuse reflections defined by a scattering coefficient. The proposed mathematical developments lead to an analytical expression of the diffusion constant that is a function of the scattering coefficient, but also on the absorption coefficient of the walls. The results obtained with this extended diffusion model are then compared with the classical diffusion model, as well as with a sound particles tracing approach considering mixed wall reflections. The comparison shows a good agreement for long rooms with uniform low absorption (α = 0.01) and uniform scattering. For a larger absorption (α = 0.1), the agreement is moderate, due to the fact that the proposed expression of the diffusion coefficient does not vary spatially. In addition, the proposed model is for now limited to uniform diffusion and should be extended in the future to more general cases.

  9. 2016 Standard Scenarios Report: A U.S. Electricity Sector Outlook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, Wesley; Mai, Trieu; Logan, Jeffrey

    The Standard Scenarios and this associated report, which are now in their second year, present an examination of some of the key aspects of the change occurring, or anticipated to occur, in the power sector over the next several decades. The Standard Scenarios consist of 18 power sector scenarios which have been projected using the National Renewable Energy Laboratory's (NREL's) Regional Energy Deployment System (ReEDS) long-term capacity expansion model and the dGen rooftop PV diffusion model. The purpose of the Standard Scenarios and this associated report is to provide context, discussion, and data to inform stakeholder decision-making regarding the futuremore » direction of U.S. power sector. As an extension to this report, the Standard Scenario outputs are presented in a downloadable format online using the Standard Scenarios' Results Viewer at http://en.openei.org/apps/reeds/. This report reflects high-level conclusions and analysis, whereas the Standard Scenarios' Results Viewer includes the scenario results that can be used for more in-depth analysis.« less

  10. Photocatalytic activity of Fe-doped CaTiO₃ under UV-visible light.

    PubMed

    Yang, He; Han, Chong; Xue, Xiangxin

    2014-07-01

    The photocatalytic degradation of methylene blue (MB) over Fe-doped CaTiO₃ under UV-visible light was investigated. The as-prepared samples were characterized using X-ray diffraction (XRD), scanning electron microscope (SEM) equipped with an energy dispersive spectrometer (EDS) system, Fourier transform infrared spectra (FT-IR), and UV-visible diffuse reflectance spectroscopy (DRS). The results show that the doping with Fe significantly promoted the light absorption ability of CaTiO₃ in the visible light region. The Fe-doped CaTiO₃ exhibited higher photocatalytic activity than CaTiO₃ for the degradation of MB. However, the photocatalytic activity of the Fe-doped CaTiO₃ was greatly influenced by the calcination temperature during the preparation process. The Fe-doped CaTiO₃ prepared at 500°C exhibited the best photocatalytic activity, with degradation of almost 100% MB (10ppm) under UV-visible light for 180 min. Copyright © 2014. Published by Elsevier B.V.

  11. Transdermal water-in-oil nanocarriers of nitric oxide for triggering penile erection.

    PubMed

    Nam, Eunryel; Yoo, Saejong; Kim, Hwi-Yool; Kim, Young-Rok; Heo, Yun Jung

    2018-05-09

    Men's sexual health can have significant effects on a man's self-esteem, sexual relationship and male reproductive functions. Although commercially available drugs (e.g., VIAGRA and CIALIS) show effective treatment of erectile dysfunction (ED), patients with severe ED fail to respond to these medicines. Topical nitric-oxide (NO) delivery to penis can be a painless, alternative solution with severe ED because NO triggers erection and diffuses to the trabecular arteries and smooth muscles in the penis. We here develop water-in-oil (W/O) nanoemulsions (NEs) that contain NO and can directly spread on the penis. We optimize NE formation conditions including hydrophilic-lipophilic balance (HLB) and ratio of oil, water and surfactants. Then, by spreading NEs on penis skin of intact middle aged dogs, we verify medication effects and safety of the NEs in vivo. The water-in-oil NEs can be a promising non-invasive medication for ED patients with low response to a phosphodiesterase type 5 (PDE5) inhibitor, thus increasing quality of life in the aging society.

  12. Rumination, experiential avoidance, and dysfunctional thinking in eating disorders

    PubMed Central

    Rawal, Adhip; Park, Rebecca J.; Williams, J. Mark G.

    2010-01-01

    The majority of research in eating disorders (ED) has investigated the content of disorder-specific thoughts, while few studies have addressed underlying cognitive-affective processes. A better understanding of processes underpinning ED may have important implications for treatment development. Two studies were conducted that investigated levels of rumination, beliefs about rumination, experiential avoidance, and aspects of schematic thinking in individuals with eating pathology. The latter was assessed with a newly designed ED-Sentence Completion Task (ED-SCT). Study 1 (N = 177) examined relations between ED psychopathology and these variables in a student population. Extending this, Study 2 (N = 26) assessed differences between patients with anorexia nervosa and healthy control participants. The results showed that ED psychopathology was related to disorder-specific cognitions, experiential avoidance as well as ruminative brooding but not reflection. A follow-up of anorexia nervosa patients indicated that changes in ED psychopathology were associated with changes in dysfunctional attitudes and maladaptive cognitive-affective processes. These findings highlight cognitive processes that may play an important role in the maintenance of eating pathology. PMID:20598670

  13. Growth Mechanism Studies of ZnO Nanowires: Experimental Observations and Short-Circuit Diffusion Analysis

    PubMed Central

    Shih, Po-Hsun

    2017-01-01

    Plenty of studies have been performed to probe the diverse properties of ZnO nanowires, but only a few have focused on the physical properties of a single nanowire since analyzing the growth mechanism along a single nanowire is difficult. In this study, a single ZnO nanowire was synthesized using a Ti-assisted chemical vapor deposition (CVD) method to avoid the appearance of catalytic contamination. Two-dimensional energy dispersive spectroscopy (EDS) mapping with a diffusion model was used to obtain the diffusion length and the activation energy ratio. The ratio value is close to 0.3, revealing that the growth of ZnO nanowires was attributed to the short-circuit diffusion. PMID:28754030

  14. Combined use of alcohol and energy drinks: Dose relationship with self-reported physiological stimulation and sedation side effects.

    PubMed

    Droste, Nicolas; Peacock, Amy; Bruno, Raimondo; Pennay, Amy; Zinkiewicz, Lucy; Lubman, Dan I; Miller, Peter

    2017-08-01

    Negative physiological stimulation and sedation side effects are experienced by a significant proportion of consumers who consume alcohol mixed with energy drinks (AmED). Few studies have compared the frequency of side effects between sessions of AmED and sessions of alcohol only within-subject, and none have explored a dose relationship. Explore the occurrence of self-reported physiological stimulant and sedative side effects between sessions of AmED and alcohol only, and at varying ED dosage levels within AmED sessions. A convenience sample of 2953 residents of New South Wales, Australia completed an online survey. N=731 AmED users reported daily caffeine intake, typical alcohol and AmED consumption, and past 12-month experience of physiological stimulation and sedation side effects during AmED and alcohol only sessions. Within-subject analyses compared occurrence of side effects between session types. Hierarchical binary logistic regression analyses explored the association of ED dose during AmED sessions with the experience of physiological side effects. There were greater odds of most stimulant side effects, and lower odds of sedation side effects, during AmED sessions compared to alcohol only sessions. Compared to one ED, consumption of three or more EDs was significantly associated with the majority of both stimulant and alcohol intoxication side effects after controlling for demographics and consumption covariates. AmED is associated with perceived changes in physiological stimulant and sedation side effects of alcohol. Experience of side effects is positively associated with ED dosage. Future research should account for varying ED dosage, and reflect real world consumption levels. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Characterizing the reflectivity of handheld display devices.

    PubMed

    Liu, Peter; Badano, Aldo

    2014-08-01

    With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using methods recommended by the American Association of Physicists in Medicine Task Group 18 (TG18). The authors modified the diffuse reflectance coefficient measurement method outlined in the TG18 report. The authors measured seven handheld display devices (two phones and five tablets) and three workstation displays. The device was attached to a black panel with Velcro. To study the effect of the back surface on the diffuse reflectance coefficient, the authors created Styrofoam masks with different size square openings and placed it in front of the device. Overall, for each display device, measurements of illuminance and reflected luminance on the display screen were taken. The authors measured with no mask, with masks of varying size, and with display-size masks, and calculated the corresponding diffuse reflectance coefficient. For all handhelds, the diffuse reflectance coefficient measured with no back panel were lower than measurements performed with a mask. The authors found an overall increase in reflectivity as the size of the mask decreases. For workstations displays, diffuse reflectance coefficients were higher when no back panel was used, and higher than with masks. In all cases, as luminance increased, illuminance increased, but not at the same rate. Since the size of handheld displays is smaller than that of workstation devices, the TG18 method suffers from a dependency on illumination condition. The authors show that the diffuse reflection coefficients can vary depending on the nature of the back surface of the illuminating box. The variability in the diffuse coefficient can be as large as 20% depending on the size of the mask. For all measurements, both luminance and illuminance increased as the size of the display window decreased. The TG18 method does not account for this variability. The authors conclude that the method requires a definitive description of the back panel used in the light source setup. The methods described in the TG18 document may need to be improved to provide consistent comparisons of desktop monitors, phones, and tablets.

  16. Tissue differentiation by diffuse reflectance spectroscopy for automated oral and maxillofacial laser surgery: ex vivo pilot study

    NASA Astrophysics Data System (ADS)

    Zam, Azhar; Stelzle, Florian; Tangermann-Gerk, Katja; Adler, Werner; Nkenke, Emeka; Schmidt, Michael; Douplik, Alexandre

    2010-02-01

    Remote laser surgery lacks of haptic feedback during the laser ablation of tissue. Hence, there is a risk of iatrogenic damage or destruction of anatomical structures like nerves or salivary glands. Diffuse reflectance spectroscopy provides a straightforward and simple approach for optical tissue differentiation. We measured diffuse reflectance from seven various tissue types ex vivo. We applied Linear Discriminant Analysis (LDA) to differentiate the seven tissue types and computed the area under the ROC curve (AUC). Special emphasis was taken on the identification of nerves and salivary glands as the most crucial tissue for maxillofacial surgery. The results show a promise for differentiating tissues as guidance for oral and maxillofacial laser surgery by means of diffuse reflectance.

  17. Determining biological tissue optical properties via integrating sphere spatial measurements

    DOEpatents

    Baba, Justin S [Knoxville, TN; Letzen, Brian S [Coral Springs, FL

    2011-01-11

    An optical sample is mounted on a spatial-acquisition apparatus that is placed in or on an enclosure. An incident beam is irradiated on a surface of the sample and the specular reflection is allowed to escape from the enclosure through an opening. The spatial-acquisition apparatus is provided with a light-occluding slider that moves in front of the sample to block portions of diffuse scattering from the sample. As the light-occluding slider moves across the front of the sample, diffuse light scattered into the area of the backside of the light-occluding slider is absorbed by back side surface of the light-occluding slider. By measuring a baseline diffuse reflectance without a light-occluding slider and subtracting measured diffuse reflectance with a light-occluding slider therefrom, diffuse reflectance for the area blocked by the light-occluding slider can be calculated.

  18. Emergency Department Telepsychiatry Service Model for a Rural Regional Health System: The First Steps.

    PubMed

    Meyer, James D; McKean, Alastair J S; Blegen, Rebecca N; Demaerschalk, Bart M

    2018-05-09

    Emergency departments (EDs) have recognized an increasing number of patients presenting with mental health (MH) concerns. This trend imposes greater demands upon EDs already operating at capacity. Many ED providers do not feel they are optimally prepared to provide the necessary MH care. One consideration in response to this dilemma is to use advanced telemedicine technology for psychiatric consultation. We examined a rural- and community-based health system operating 21 EDs, none of which has direct access to psychiatric consultation. Dedicated beds to MH range from zero (in EDs with only 3 beds) to 6 (in an ED with 38 beds). We conducted a needs assessment of this health system. This included a survey of emergency room providers with a 67% response rate and site visits to directly observe patient flow and communication with ED staff. A visioning workshop provided input from ED staff. Data were also obtained, which reflected ED admissions for the year 2015. The data provide a summary of provider concerns, a summary of MH presentations and diagnosis, and age groupings. The data also provide a time when most MH concerns present to the ED. Based upon these results, a proposed model for delivering comprehensive regional emergency telepsychiatry and behavioral health services is proposed. Emergency telepsychiatry services may be a tenable solution for addressing the shortage of psychiatric consultation to EDs in light of increasing demand for MH treatment in the ED.

  19. SeaWiFS long-term solar diffuser reflectance and sensor noise analyses.

    PubMed

    Eplee, Robert E; Patt, Frederick S; Barnes, Robert A; McClain, Charles R

    2007-02-10

    The NASA Ocean Biology Processing Group's Calibration and Validation (Cal/Val) team has undertaken an analysis of the mission-long Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) solar calibration time series to assess the long-term degradation of the solar diffuser reflectance over 9 years on orbit. The SeaWiFS diffuser is an aluminum plate coated with YB71 paint. The bidirectional reflectance distribution function of the diffuser was not fully characterized before launch, so the Cal/Val team has implemented a regression of the solar incidence angles and the drift in the node of the satellite's orbit against the diffuser time series to correct for solar incidence angle effects. An exponential function with a time constant of 200 days yields the best fit to the diffuser time series. The decrease in diffuser reflectance over the mission is wavelength dependent, ranging from 9% in the blue (412 nm) to 5% in the red and near infrared (670-865 nm). The Cal/Val team has developed a methodology for computing the signal-to-noise ratio (SNR) for SeaWiFS on orbit from the diffuser time series corrected for both the varying solar incidence angles and the diffuser reflectance degradation. A sensor noise model is used to compare on-orbit SNRs computed for radiances reflected from the diffuser with prelaunch SNRs measured at typical radiances specified for the instrument. To within the uncertainties in the measurements, the SNRs for SeaWiFS have not changed over the mission. The on-orbit performance of the SeaWiFS solar diffuser should offer insight into the long-term on-orbit performance of solar diffusers on other instruments, such as the Moderate-Resolution Imaging Spectrometer [currently flying on the Earth Observing System (EOS) Terra and Aqua satellites], the Visible and Infrared Radiometer Suite [scheduled to fly on the NASA National Polar-orbiting Operational Environmental Satellite System (NPOESS) and NPOESS Preparatory Project (NPP) satellites] and the Advanced Baseline Imager [scheduled to fly on the National Oceanic and Atmospheric Administration Geostationary Environmental Operational Satellite Series R (GOES-R) satellites].

  20. SeaWiFS long-term solar diffuser reflectance and sensor noise analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eplee, Robert E. Jr.; Patt, Frederick S.; Barnes, Robert A.

    The NASA Ocean Biology Processing Group's Calibration and Validation(Cal/Val) team has undertaken an analysis of the mission-long Sea-Viewing Wide Field-of-View Sensor (SeaWiFS)solar calibration time series to assess the long-term degradation of the solar diffuser reflectance over 9 years on orbit. The SeaWiFS diffuser is an aluminum plate coated with YB71 paint. The bidirectional reflectance distribution function of the diffuser was not fully characterized before launch,so the Cal/Val team has implemented a regression of the solar incidence angles and the drift in the node of the satellite's orbit against the diffuser time series to correct for solar incidence angle effects. Anmore » exponential function with a time constant of 200 days yields the best fit to the diffuser time series.The decrease in diffuser reflectance over the mission is wavelength dependent,ranging from 9% in the blue(412 nm) to 5% in the red and near infrared(670-865 nm). The Cal/Val team has developed a methodology for computing the signal-to-noise ratio (SNR) for SeaWiFS on orbit from the diffuser time series corrected for both the varying solar incidence angles and the diffuser reflectance degradation. A sensor noise model is used to compare on-orbit SNRs computed for radiances reflected from the diffuser with prelaunch SNRs measured at typical radiances specified for the instrument. To within the uncertainties in the measurements, the SNRs for SeaWiFS have not changed over the mission. The on-orbit performance of the SeaWiFS solar diffuser should offer insight into the long-term on-orbit performance of solar diffusers on other instruments, such as the Moderate-Resolution Imaging Spectrometer [currently flying on the Earth Observing System (EOS) Terra and Aqua satellites], the Visible and Infrared Radiometer Suite [scheduled to fly on the NASA National Polar-orbiting Operational Environmental Satellite System (NPOESS) and NPOESS Preparatory Project (NPP) satellites] and the Advanced Baseline Imager [scheduled to fly on the National Oceanic and Atmospheric Administration Geostationary Environmental Operational Satellite Series R (GOES-R) satellites].« less

  1. SeaWiFS long-term solar diffuser reflectance and sensor noise analyses

    NASA Astrophysics Data System (ADS)

    Eplee, Robert E., Jr.; Patt, Frederick S.; Barnes, Robert A.; McClain, Charles R.

    2007-02-01

    The NASA Ocean Biology Processing Group's Calibration and Validation (Cal/Val) team has undertaken an analysis of the mission-long Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) solar calibration time series to assess the long-term degradation of the solar diffuser reflectance over 9 years on orbit. The SeaWiFS diffuser is an aluminum plate coated with YB71 paint. The bidirectional reflectance distribution function of the diffuser was not fully characterized before launch, so the Cal/Val team has implemented a regression of the solar incidence angles and the drift in the node of the satellite's orbit against the diffuser time series to correct for solar incidence angle effects. An exponential function with a time constant of 200 days yields the best fit to the diffuser time series. The decrease in diffuser reflectance over the mission is wavelength dependent, ranging from 9% in the blue (412 nm) to 5% in the red and near infrared (670-865 nm). The Cal/Val team has developed a methodology for computing the signal-to-noise ratio (SNR) for SeaWiFS on orbit from the diffuser time series corrected for both the varying solar incidence angles and the diffuser reflectance degradation. A sensor noise model is used to compare on-orbit SNRs computed for radiances reflected from the diffuser with prelaunch SNRs measured at typical radiances specified for the instrument. To within the uncertainties in the measurements, the SNRs for SeaWiFS have not changed over the mission. The on-orbit performance of the SeaWiFS solar diffuser should offer insight into the long-term on-orbit performance of solar diffusers on other instruments, such as the Moderate-Resolution Imaging Spectrometer [currently flying on the Earth Observing System (EOS) Terra and Aqua satellites], the Visible and Infrared Radiometer Suite [scheduled to fly on the NASA National Polar-orbiting Operational Environmental Satellite System (NPOESS) and NPOESS Preparatory Project (NPP) satellites] and the Advanced Baseline Imager [scheduled to fly on the National Oceanic and Atmospheric Administration Geostationary Environmental Operational Satellite Series R (GOES-R) satellites].

  2. Design of a Film-Cooled Entraining Diffuser.

    DTIC Science & Technology

    1980-04-01

    AD-A783 951 DEFENCE RESEARCH ESTABLISHMENT SUFFIELD RALSTON (ALBERTA) FIG 20/4 NL3 DESIGN OF A FILM-COOLED ENTRAINING DIFFUSER. 1U) APR 80 S B MURRAY...S.B. Murray C PCN 27C01 April 1980 80 4 29 004 DEFENCE RESEARCH ESTABLISHMENT SUFFIELD: RALSTON: ALBERTA WARNING rht ... , i. to - °aton is per lle...ulje(f to -ogoltio • IIl proprieh’~ra~r ind wtent it hh , i j l - UNCLASS I FI ED Li m DEFENCE RESEARCH ESTABLISHMENT SUFFIELD RALSTON ALBERTA

  3. Developing a Characterisation of Citizenship Education: Issues Arising from Work Undertaken in a Higher Education Network

    ERIC Educational Resources Information Center

    Davies, Ian; Arthur, James; Harrison, Tom; Watson, Helen

    2008-01-01

    In order to understand better the way in which the emerging field of citizenship education is being characterised we reflect on work emerging from a higher education network (citizED) for citizenship education. Three of the four authors of this article are closely involved in that network. CitizED was established with funding from the Teacher…

  4. Synthesis and spectroscopic study of CdS nanoparticles using hydrothermal method

    NASA Astrophysics Data System (ADS)

    AL-Mamoori, Mohammed H. K.; Mahdi, Dunia K.; Al-Shrefi, Saif M.

    2018-05-01

    In this work, cadmium sulfide nanoparticles (powder) with diameter 50.8 nm was prepared using hydrothermal method. The structural and optical properties of CdS nanoparticles was studied by X-ray diffraction, FESEM, EDS, FTIR, UV-Diffuse Reflectance spectroscopy and Photoluminance spectrum. X-ray diffraction reveal the formation the purity of prepared phase of CdS particles with hexagonal wurtzite structure with particle size 31.8nm by using sheerer equation. The energy dispersion scattering (EDS) examination explains that the sample is composed of a large amount of Cd and S which are exactly CdS nanoparticles and there is a very small trace of (Zn) and (O) element observed because of there is a small pollutions in the measurement place of samples. FESEM shows the spherical shape of nanoparticles with around 50.8 nm diameter. The optical absorption spectral study identified the red shift of the sample in comparison to bulk ZnO in three dimensions. Photoluminance spectrum (PL) at room temperature showed that there are two luminescence peaks at 433.14 nm and 518.21nm. Samples demonstrate a sharp emission band at around 433.18 nm, which is attributed to the typical exciton luminescence. The broad band at 518.21nm which were attributed to the trapped luminescence. The green emission band at 518.21 nm was associated with the emission due to electronic transition from the conduction band to an accepter level due to interstitial sulphur ion.

  5. Structural and luminescence properties of CaTiO{sub 3}:Eu{sup 3+} phosphor synthesized by chemical co-precipitation method for the application of solid state lighting devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Dhananjay Kumar, E-mail: dksism89@gmail.com; Manam, J., E-mail: jairam.manam@gmail.com

    2016-05-06

    The present work report a series of trivalent Europium (Eu{sup 3+}) doped well crystallized perovskite CaTiO{sub 3} phosphors successfully synthesized by chemical co-precipitation method. The crystal structure was confirmed by X-ray diffraction (XRD) which is in good agreement with pure orthorhombic phase with space group Pbnm, and it also indicated that the incorporation of the dopant did not affect the crystal structure. The impact of doping on the photoluminescence performances of the sample has been investigated by emission, excitation, and diffuse reflectance spectra at the room temperature. Photoluminescence spectra of Eu{sup 3+} doped CaTiO{sub 3} nanophosphor revealed the characteristic emissionmore » peak around wavelength 618 nm in the visible region upon the excitation of near-UV light at wavelength 397 nm due to {sup 5}D{sub 0} → {sup 7}F{sub 2} transition in Eu{sup 3+}. It was further proved that the dipole– dipole interactions results in the concentration quenching of Eu{sup 3+} in CaTiO{sub 3}:Eu{sup 3+} nanophosphors. The elemental composition of sample carried out by energy dispersive spectroscopy (EDS). EDS analysis reveals that the Eu{sup 3+} doped successfully into host CaTiO{sub 3}. The experimental result reveals that prepared nanophosphor can be used in the application of solid state lighting devices.« less

  6. How do clinicians with different training backgrounds manage walk-in patients in the ED setting?

    PubMed

    Harris, Tim; McDonald, Keith

    2014-12-01

    To compare the initial assessment and management of walk-in emergency department (ED) patients between different types of healthcare providers. A large teaching hospital with an annual ED census of 140 000 adult patients. A random sample of 384 patients who self-presented to the ED was obtained. A detailed analysis of each patient record was performed by two clinicians. Data were obtained on the presenting condition, and disposition of each patient, either into the ED for further assessment, or discharge. GPs were significantly more likely to discharge patients home as compared to emergency nurses. ED senior nurses were more likely than GPs to stream patients into the ED for further assessment. Of the patients referred into the ED for further assessment by senior ED nurses, the majority were discharged home. There were insufficient numbers of emergency physician assessments for meaningful statistical analysis. The clinician groups studied here demonstrated different patterns of discharge and referral, reflecting their training and experience. When planning operational procedures, the training and background of the staff allocated to each area should be considered. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Broadband diffuse terahertz wave scattering by flexible metasurface with randomized phase distribution

    PubMed Central

    Zhang, Yin; Liang, Lanju; Yang, Jing; Feng, Yijun; Zhu, Bo; Zhao, Junming; Jiang, Tian; Jin, Biaobing; Liu, Weiwei

    2016-01-01

    Suppressing specular electromagnetic wave reflection or backward radar cross section is important and of broad interests in practical electromagnetic engineering. Here, we present a scheme to achieve broadband backward scattering reduction through diffuse terahertz wave reflection by a flexible metasurface. The diffuse scattering of terahertz wave is caused by the randomized reflection phase distribution on the metasurface, which consists of meta-particles of differently sized metallic patches arranged on top of a grounded polyimide substrate simply through a certain computer generated pseudorandom sequence. Both numerical simulations and experimental results demonstrate the ultralow specular reflection over a broad frequency band and wide angle of incidence due to the re-distribution of the incident energy into various directions. The diffuse scattering property is also polarization insensitive and can be well preserved when the flexible metasurface is conformably wrapped on a curved reflective object. The proposed design opens up a new route for specular reflection suppression, and may be applicable in stealth and other technology in the terahertz spectrum. PMID:27225031

  8. Broadband diffuse terahertz wave scattering by flexible metasurface with randomized phase distribution.

    PubMed

    Zhang, Yin; Liang, Lanju; Yang, Jing; Feng, Yijun; Zhu, Bo; Zhao, Junming; Jiang, Tian; Jin, Biaobing; Liu, Weiwei

    2016-05-26

    Suppressing specular electromagnetic wave reflection or backward radar cross section is important and of broad interests in practical electromagnetic engineering. Here, we present a scheme to achieve broadband backward scattering reduction through diffuse terahertz wave reflection by a flexible metasurface. The diffuse scattering of terahertz wave is caused by the randomized reflection phase distribution on the metasurface, which consists of meta-particles of differently sized metallic patches arranged on top of a grounded polyimide substrate simply through a certain computer generated pseudorandom sequence. Both numerical simulations and experimental results demonstrate the ultralow specular reflection over a broad frequency band and wide angle of incidence due to the re-distribution of the incident energy into various directions. The diffuse scattering property is also polarization insensitive and can be well preserved when the flexible metasurface is conformably wrapped on a curved reflective object. The proposed design opens up a new route for specular reflection suppression, and may be applicable in stealth and other technology in the terahertz spectrum.

  9. Barriers and Facilitators to Implementing the HEADS-ED: A Rapid Screening Tool for Pediatric Patients in Emergency Departments.

    PubMed

    MacWilliams, Kate; Curran, Janet; Racek, Jakub; Cloutier, Paula; Cappelli, Mario

    2017-12-01

    This study sought to identify barriers and facilitators to the implementation of the HEADS-ED, a screening tool appropriate for use in the emergency department (ED) that facilitates standardized assessments, discharge planning, charting, and linking pediatric mental health patients to appropriate community resources. A qualitative theory-based design was used to identify barriers and facilitators to implementing the HEADS-ED tool. Focus groups were conducted with participants recruited from 6 different ED settings across 2 provinces (Ontario and Nova Scotia). The Theoretical Domains Framework was used as a conceptual framework to guide data collection and to identify themes from focus group discussions. The following themes spanning 12 domains were identified as reflective of participants' beliefs about the barriers and facilitators to implementing the HEADS-ED tool: knowledge, skills, beliefs about capabilities, social professional role and identity, optimism, beliefs about consequences, reinforcement, environmental context and resources, social influences, emotion, behavioral regulation and memory, and attention and decision process. The HEADS-ED has the potential to address the need for better discharge planning, complete charting, and standardized assessments for the increasing population of pediatric mental health patients who present to EDs. This study has identified potential barriers and facilitators, which should be considered when developing an implementation plan for adopting the HEADS-ED tool into practice within EDs.

  10. Ultra-broadband and planar sound diffuser with high uniformity of reflected intensity

    NASA Astrophysics Data System (ADS)

    Fan, Xu-Dong; Zhu, Yi-Fan; Liang, Bin; Yang, Jing; Yang, Jun; Cheng, Jian-Chun

    2017-09-01

    Schroeder diffusers, as a classical design of acoustic diffusers proposed over 40 years ago, play key roles in many practical scenarios ranging from architectural acoustics to noise control to particle manipulation. Despite the great success of conventional acoustic diffusers, it is still worth pursuing ideal acoustic diffusers that are essentially expected to produce perfect sound diffuse reflection within the unlimited bandwidth. Here, we propose a different mechanism for designing acoustic diffusers to overcome the basic limits in intensity uniformity and working bandwidth in the previous designs and demonstrate a practical implementation by acoustic metamaterials with dispersionless phase-steering capability. In stark contrast to the existing production of diffuse fields relying on random scattering of sound energy by using a specific mathematical number sequence of periodically distributed unit cells, we directly mold the reflected wavefront into the desired shape by precisely manipulating the local phases of individual subwavelength metastructures. We also benchmark our design via numerical simulation with a commercially available Schroeder diffuser, and the results verify that our proposed diffuser scatters incident acoustic energy into all directions more uniformly within an ultra-broad band regardless of the incident angle. Furthermore, our design enables further improvement of the working bandwidth just by simply downscaling each individual element. With ultra-broadband functionality and high uniformity of reflected intensity, our metamaterial-based production of the diffusive field opens a route to the design and application of acoustic diffusers and may have a significant impact on various fields such as architectural acoustics and medical ultrasound imaging/treatment.

  11. Near-infrared diffuse reflection systems for chlorophyll content of tomato leaves measurement

    NASA Astrophysics Data System (ADS)

    Jiang, Huanyu; Ying, Yibin; Lu, Huishan

    2006-10-01

    In this study, two measuring systems for chlorophyll content of tomato leaves were developed based on near-infrared spectral techniques. The systems mainly consists of a FT-IR spectrum analyzer, optic fiber diffuses reflection accessories and data card. Diffuse reflectance of intact tomato leaves was measured by an optics fiber optic fiber diffuses reflection accessory and a smart diffuses reflection accessory. Calibration models were developed from spectral and constituent measurements. 90 samples served as the calibration sets and 30 samples served as the validation sets. Partial least squares (PLS) and principal component regression (PCR) technique were used to develop the prediction models by different data preprocessing. The best model for chlorophyll content had a high correlation efficient of 0.9348 and a low standard error of prediction RMSEP of 4.79 when we select full range (12500-4000 cm -1), MSC path length correction method by the log(1/R). The results of this study suggest that FT-NIR method can be feasible to detect chlorophyll content of tomato leaves rapidly and nondestructively.

  12. Physician Impressions of Physical Therapist Practice in the Emergency Department: Descriptive, Comparative Analysis Over Time.

    PubMed

    Fruth, Stacie J; Wiley, Steve

    2016-09-01

    Emergency department (ED) use in the United States is expected to rapidly increase. Nearly half of all ED visits are classified as semiurgent or nonurgent, and many fall into the musculoskeletal category. Despite growing international evidence that patients are appropriately and safely managed by ED physical therapists in a time-efficient manner, physical therapist practice in EDs is not widely understood or utilized in the United States. To date, no studies have reported the impressions of ED physicians about this practice. The purposes of this study were: (1) to assess ED physicians' impressions of ED physical therapist practice 2 years after practice was initiated and (2) to determine whether physicians' impressions changed 7 years later. All ED staff physicians and medical residents at a level I trauma hospital were invited to complete a survey in 2004 and 2011. In both years, a majority of physicians reported favorable impressions of ED physical therapist practice. Physical therapists were valued for educating patients about safety and injury prevention, providing appropriate gait training, assisting with disposition planning, and providing interventions as alternatives to pain medication. Many physicians supported standing physical therapist orders for certain musculoskeletal conditions. The most common concern was the additional time that patients spend in the ED for a physical therapist consult. The results of this study may not reflect the impressions of physicians in all EDs that employ physical therapists. Emergency department physicians reported favorable impressions of ED physical therapist practice 2 years and 9 years following its implementation in this hospital. This study showed that ED physicians support standing physical therapist orders for certain musculoskeletal conditions, which suggests that direct triage to ED physical therapists for these conditions could be considered. © 2016 American Physical Therapy Association.

  13. Hazard calculations of diffuse reflected laser radiation for the SELENE program

    NASA Technical Reports Server (NTRS)

    Miner, Gilda A.; Babb, Phillip D.

    1993-01-01

    The hazards from diffuse laser light reflections off water clouds, ice clouds, and fog and from possible specular reflections off ice clouds were assessed with the American National Standards (ANSI Z136.1-1986) for the free-electron-laser parameters under consideration for the Segmented Efficient Laser Emission for Non-Nuclear Electricity (SELENE) Program. Diffuse laser reflection hazards exist for water cloud surfaces less than 722 m in altitude and ice cloud surfaces less than 850 m in altitude. Specular reflections from ice crystals in cirrus clouds are not probable; however, any specular reflection is a hazard to ground observers. The hazard to the laser operators and any ground observers during heavy fog conditions is of such significant magnitude that the laser should not be operated in fog.

  14. Right service, right place: optimising utilisation of a community nursing service to reduce planned re-presentations to the emergency department.

    PubMed

    Lawton, Jessica Kirsten; Kinsman, Leigh; Dalton, Lisa; Walsh, Fay; Bryan, Helen; Williams, Sharon

    2017-01-01

    Congruent with international rising emergency department (ED) demand, a focus on strategies and services to reduce burden on EDs and improve patient outcomes is necessary. Planned re-presentations of non-urgent patients at a regional Australian hospital exceeded 1200 visits during the 2013-2014 financial year. Planned re-presentations perpetuate demand and signify a lack of alternative services for non-urgent patients. The Community Nursing Enhanced Connections Service (CoNECS) collaboratively evolved between acute care and community services in 2014 to reduce planned ED re-presentations. This study aimed to investigate the evolution and impact of a community nursing service to reduce planned re-presentations to a regional Australian ED and identify enablers and barriers to interventionist effectiveness. A mixed-methods approach evaluated the impact of CoNECS. Data from hospital databases including measured numbers of planned ED re-presentations by month, time of day, age, gender and reason were used to calculate referral rates to CoNECS. These results informed two semistructured focus groups with ED and community nurses. The researchers used a theoretical lens, 'diffusion of innovation', to understand how this service could inform future interventions. Analyses showed that annual ED planned re-presentations decreased by 43% (527 presentations) after implementation. Three themes emerged from the focus groups. These were right service at the right time, nursing uncertainty and system disconnect and medical disengagement. CoNECS reduced overall ED planned re-presentations and was sustained longer than many complex service-level interventions. Factors supporting the service were endorsement from senior administration and strong leadership to drive responsive quality improvement strategies. This study identified a promising alternative service outside the ED, highlighting possibilities for other hospital emergency services aiming to reduce planned re-presentations.

  15. Improved algorithm for estimating optical properties of food and biological materials using spatially-resolved diffuse reflectance

    USDA-ARS?s Scientific Manuscript database

    In this research, the inverse algorithm for estimating optical properties of food and biological materials from spatially-resolved diffuse reflectance was optimized in terms of data smoothing, normalization and spatial region of reflectance profile for curve fitting. Monte Carlo simulation was used ...

  16. Chasing Woozles? A Personal Reflection on a Quarter-Century in Ed Tech, and an Attempt to Peer Ahead through the Fog

    ERIC Educational Resources Information Center

    Bergeron, Corrie

    2014-01-01

    While it's easy to get caught up in the frenetic drive to do the Next Big New Thing in educational technology, it's helpful to remember that a lot of important things "don't" change. But, today, we face almost constant change, and that has serious implications for education and ed-tech professionals. This article looks back at where…

  17. Injury thresholds for topical-cream-coated skin of hairless guinea pigs (cavia porcellus) in the near-infrared region

    NASA Astrophysics Data System (ADS)

    Pocock, Ginger M.; Zohner, Justin J.; Stolarski, David J.; Buchanan, Kelvin C.; Jindra, Nichole M.; Figueroa, Manuel A.; Chavey, Lucas J.; Imholte, Michelle L.; Thomas, Robert J.; Rockwell, Benjamin A.

    2006-02-01

    The reflectance and absorption of the skin plays a vital role in determining how much radiation will be absorbed by human tissue. Any substance covering the skin would change the way radiation is reflected and absorbed and thus the extent of thermal injury. Hairless guinea pigs (cavia porcellus) in vivo were used to evaluate how the minimum visible lesion threshold for single-pulse laser exposure is changed with a topical agent applied to the skin. The ED 50 for visible lesions due to an Er: glass laser at 1540-nm with a pulse width of 50-ns was determined, and the results were compared with model predictions using a skin thermal model. The ED50 is compared with the damage threshold of skin coated with a highly absorbing topical cream at 1540 nm to determine its effect on damage pathology and threshold. The ED 50 for the guinea pig was then compared to similar studies using Yucatan minipigs and Yorkshire pigs at 1540-nm and nanosecond pulse duration. 1,2 The damage threshold at 24-hours of a Yorkshire pig for a 2.5-3.5-mm diameter beam for 100 ns was 3.2 Jcm -2; very similar to our ED 50 of 3.00 Jcm -2 for the hairless guinea pigs.

  18. Properties of seismic absorption induced reflections

    NASA Astrophysics Data System (ADS)

    Zhao, Haixia; Gao, Jinghuai; Peng, Jigen

    2018-05-01

    Seismic reflections at an interface are often regarded as the variation of the acoustic impedance (product of seismic velocity and density) in a medium. In fact, they can also be generated due to the difference in absorption of the seismic energy. In this paper, we investigate the properties of such reflections. Based on the diffusive-viscous wave equation and elastic diffusive-viscous wave equation, we investigate the dependency of the reflection coefficients on frequency, and their variations with incident angles. Numerical results at a boundary due to absorption contrasts are compared with those resulted from acoustic impedance variation. It is found that, the reflection coefficients resulted from absorption depend significantly on the frequency especially at lower frequencies, but vary very slowly at small incident angles. At the higher frequencies, the reflection coefficients of diffusive-viscous wave and elastic diffusive-viscous wave are close to those of acoustic and elastic cases, respectively. On the other hand, the reflections caused by acoustic impedance variation are independent of frequency but vary distinctly with incident angles before the critical angle. We also investigate the difference between the seismograms generated in the two different media. The numerical results show that the amplitudes of these reflected waves are attenuated and their phases are shifted. However, the reflections obtained by acoustic impedance contrast, show no significant amplitude attenuation and phase shift.

  19. Destructive and non-destructive evaluation of cu/cu diffusion bonding with interlayer aluminum

    NASA Astrophysics Data System (ADS)

    Santosh Kumar, A.; Mohan, T.; Kumar, S. Suresh; Ravisankar, B.

    2018-03-01

    The current study is established an inspection procedure for assessing quality of diffusion bonded joints using destructive and non-destructive method. Diffusion bonding of commercially pure copper with aluminium interlayer was carried out uniaxial load at 15MPa for different temperatures under holding time 60 min in vacuum atmosphere. The bond qualities were determined by destructive and non-destructive testing method (ultrasonic C- scan). The bond interface and bonded samples were analysed using optical and scanning electron microscopy (SEM). The element composition of the fractured and bonded area is determined using the Energy Dispersive Spectrometry (EDS). The bond quality obtained by both testing methods and its parameters are correlated. The optimized bonding parameter for best bonding characteristics for copper diffusion bonding with aluminum interlayer is reported.

  20. The Role of the Army in Infrastructure and Capacity Building

    DTIC Science & Technology

    2010-02-01

    Issues Volume I: Theory of War and Strategy 3rd edition, ed. J. Boone Bartholomees, Jr. (Carlisle: USAWC Strategic Studies Institute, 2009), 145...efforts. 34 Raj M. Desai and Homi Kharas, Do Philanthropic Citizens Behave Like Governments? Internet-Based Platforms and the Diffusion of International

  1. Intensity-Value Corrections for Integrating Sphere Measurements of Solid Samples Measured Behind Glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Timothy J.; Bernacki, Bruce E.; Redding, Rebecca L.

    2014-11-01

    Accurate and calibrated directional-hemispherical reflectance spectra of solids are important for both in situ and remote sensing. Many solids are in the form of powders or granules and to measure their diffuse reflectance spectra in the laboratory, it is often necessary to place the samples behind a transparent medium such as glass for the ultraviolet (UV), visible, or near-infrared spectral regions. Using both experimental methods and a simple optical model, we demonstrate that glass (fused quartz in our case) leads to artifacts in the reflectance values. We report our observations that the measured reflectance values, for both hemispherical and diffusemore » reflectance, are distorted by the additional reflections arising at the air–quartz and sample–quartz interfaces. The values are dependent on the sample reflectance and are offset in intensity in the hemispherical case, leading to measured values up to ~6% too high for a 2% reflectance surface, ~3.8% too high for 10% reflecting surfaces, approximately correct for 40–60% diffuse-reflecting surfaces, and ~1.5% too low for 99% reflecting Spectralon® surfaces. For the case of diffuse-only reflectance, the measured values are uniformly too low due to the polished glass, with differences of nearly 6% for a 99% reflecting matte surface. The deviations arise from the added reflections from the quartz surfaces, as verified by both theory and experiment, and depend on sphere design. Finally, empirical correction factors were implemented into post-processing software to redress the artifact for hemispherical and diffuse reflectance data across the 300–2300 nm range.« less

  2. Erectile dysfunction (ED) is a shared sexual concern of couples II: association of female partner characteristics with male partner ED treatment seeking and phosphodiesterase type 5 inhibitor utilization.

    PubMed

    Fisher, William A; Eardley, Ian; McCabe, Marita; Sand, Michael

    2009-11-01

    Erectile dysfunction (ED) is a prevalent condition that impacts on both patients and their female partners. ED may therefore be regarded as a shared sexual concern for couples. The current analysis of the Female Experience of Men's Attitudes to Life Events and Sexuality (FEMALES) study data addresses women's perceptions, beliefs, and attitudes concerning their partner's ED, and whether these are associated with the likelihood of the male partner seeking medical advice and utilizing phosphodiesterase type 5 inhibitors. The current research sought to explore the association of female partners' perceptions of male partners' ED and male partners' medical consultation and treatment seeking for ED. Questionnaires were sent to partners of men who participated in the Men's Attitudes to Life Events and Sexuality (MALES) 2004 study, and who consented to their partner's involvement. A modified version of the questionnaire used in the MALES study was developed for the FEMALES study, reflecting the female partner's perspective. A 65-item questionnaire assessing women's perceptions, beliefs, and attitudes regarding various aspects of ED. Women's perceptions of the nature and causes of their partner's ED were significantly associated with men's treatment seeking and utilization. Significant associations were observed between women's level of satisfaction with the relationship before ED onset; perceptions of the impact of ED on quality of life; desire to deal with ED; attitudes to ED treatment; and the treatment-seeking behavior of the male partner. Multivariate regression analyses identified a mixture of female and male partner perceptions and attitudes that uniquely accounted for >30% of the variance in men's ED treatment-seeking behavior and treatment utilization. This study illustrates the importance of the female partner's attitudes to ED in men's ED treatment-seeking behavior. These findings strongly support the potential benefits of partner integration into ED consultation and treatment strategies.

  3. Are eating disorders "all about control?" The elusive psychopathology of nonfat phobic presentations.

    PubMed

    Murray, Helen B; Coniglio, Kathryn; Hartmann, Andrea S; Becker, Anne E; Eddy, Kamryn T; Thomas, Jennifer J

    2017-11-01

    There are a subset of individuals with eating disorders (EDs) who do not overevaluate body shape/weight (i.e., nonfat phobic ED; NFP-ED). According to the transdiagnostic cognitive-behavioral conceptualization of EDs, a need for control, in general, is hypothesized as the core psychopathology of NFP-EDs, with shape- and weight-related motivations for ED behavior merely superimposed in FP-ED presentations. This study tested the need for control as motivation for restriction in NFP-ED, using items aimed at assessing control from the Eating Disorder Examination (EDE) Restraint scale. Females ages 13-27 years consecutively admitted to residential treatment completed the EDE, Eating Disorder Inventory-3 Drive for Thinness subscale (EDI-DFT), and other self-report measures of psychopathology. We included patients with DSM-5 EDs, but excluded patients with avoidant/restrictive food intake disorder. Twenty participants had NFP-ED (≤14 on EDI-DFT) and 124 had fatphobic ED (FP-ED; >14 on EDI-DFT). NFP-ED scored significantly lower than FP-ED on EDE Restraint scale shape/weight [χ 2 (1) = 10.73-35.62, p's < .01] and on control items [χ 2 (1) = 10.72-20.62, p's < .01], in addition to scoring lower on measures of general psychopathology and impairment. Findings suggest those with NFP-ED report lower psychopathology overall and the new EDE Restraint scale control items do not capture additional motivation for restriction beyond that captured in the original Restraint scale shape/weight items. Future research should examine whether this latter finding is due to a minimizing response style in NFP-ED, an incomplete capture of desire for control by the EDE assessment method, or indeed reflects that need for control does not motivate restriction in NFP-EDs. © 2017 Wiley Periodicals, Inc.

  4. New mounting improves solar-cell efficiency

    NASA Technical Reports Server (NTRS)

    Shepard, N. F., Jr.

    1980-01-01

    Method boosts output by about 20 percent by trapping and redirecting solar radiation without increasing module depth. Mounted solar-cell array is covered with internally reflecting plate. Plate is attached to each cell by transparent adhesive, and space between cells is covered with layer of diffusely reflecting material. Solar energy falling on space between cells is diffused and reflected internally by plate until it is reflected onto solar cell.

  5. Diffuse reflectance of TiO 2 pigmented paints: Spectral dependence of the average pathlength parameter and the forward scattering ratio

    NASA Astrophysics Data System (ADS)

    Vargas, William E.; Amador, Alvaro; Niklasson, Gunnar A.

    2006-05-01

    Diffuse reflectance spectra of paint coatings with different pigment concentrations, normally illuminated with unpolarized radiation, have been measured. A four-flux radiative transfer approach is used to model the diffuse reflectance of TiO2 (rutile) pigmented coatings through the solar spectral range. The spectral dependence of the average pathlength parameter and of the forward scattering ratio for diffuse radiation, are explicitly incorporated into this four-flux model from two novel approximations. The size distribution of the pigments has been taken into account to obtain the averages of the four-flux parameters: scattering and absorption cross sections, forward scattering ratios for collimated and isotropic diffuse radiation, and coefficients involved in the expansion of the single particle phase function in terms of Legendre polynomials.

  6. The study of frequency-scan photothermal reflectance technique for thermal diffusivity measurement

    DOE PAGES

    Hua, Zilong; Ban, Heng; Hurley, David H.

    2015-05-05

    A frequency scan photothermal reflectance technique to measure thermal diffusivity of bulk samples is studied in this manuscript. Similar to general photothermal reflectance methods, an intensity-modulated heating laser and a constant intensity probe laser are used to determine the surface temperature response under sinusoidal heating. The approach involves fixing the distance between the heating and probe laser spots, recording the phase lag of reflected probe laser intensity with respect to the heating laser frequency modulation, and extracting thermal diffusivity using the phase lag – (frequency) 1/2 relation. The experimental validation is performed on three samples (SiO 2, CaF 2 andmore » Ge), which have a wide range of thermal diffusivities. The measured thermal diffusivity values agree closely with literature values. Lastly, compared to the commonly used spatial scan method, the experimental setup and operation of the frequency scan method are simplified, and the uncertainty level is equal to or smaller than that of the spatial scan method.« less

  7. The study of frequency-scan photothermal reflectance technique for thermal diffusivity measurement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hua, Zilong; Ban, Heng; Hurley, David H.

    A frequency scan photothermal reflectance technique to measure thermal diffusivity of bulk samples is studied in this manuscript. Similar to general photothermal reflectance methods, an intensity-modulated heating laser and a constant intensity probe laser are used to determine the surface temperature response under sinusoidal heating. The approach involves fixing the distance between the heating and probe laser spots, recording the phase lag of reflected probe laser intensity with respect to the heating laser frequency modulation, and extracting thermal diffusivity using the phase lag – (frequency) 1/2 relation. The experimental validation is performed on three samples (SiO 2, CaF 2 andmore » Ge), which have a wide range of thermal diffusivities. The measured thermal diffusivity values agree closely with literature values. Lastly, compared to the commonly used spatial scan method, the experimental setup and operation of the frequency scan method are simplified, and the uncertainty level is equal to or smaller than that of the spatial scan method.« less

  8. Soft tissue differentiation by diffuse reflectance spectroscopy

    NASA Astrophysics Data System (ADS)

    Zam, Azhar; Stelzle, Florian; Nkenke, Emeka; Tangermann-Gerk, Katja; Schmidt, Michael; Adler, Werner; Douplik, Alexandre

    2009-07-01

    Laser surgery gives the possibility to work remotely which leads to high precision, little trauma and high level sterility. However these advantages are coming with the lack of haptic feedback during the laser ablation of tissue. Therefore additional means are required to control tissue-specific ablation during laser surgery supporting the surgeon regardless of experience and skills. Diffuse Reflectance Spectroscopy provides a straightforward and simple approach for optical tissue differentiation. We measured diffuse reflectance from four various tissue types ex vivo. We applied Linear Discriminant Analysis (LDA) to differentiate the four tissue types and computed the area under the ROC curve (AUC). Special emphasis was taken on the identification of nerve as the most crucial tissue for maxillofacial surgery. The results show a promise for differentiating soft tissues as guidance for tissue-specific laser surgery by means of the diffuse reflectance.

  9. Older adolescent presentations to a children's hospital emergency department.

    PubMed

    Batra, Shweta; Ng, Elaine Yu Ching; Foo, Feng; Noori, Omar; McCaskill, Mary; Steinbeck, Katharine

    2016-08-01

    To describe the characteristics, diagnoses and outcomes of older adolescents, aged 16-19 years, presenting to a paediatric ED. A retrospective review of total ED presentations by older adolescents to a tertiary paediatric hospital between 2010 and 2012, inclusive, was undertaken to determine if behavioural or mental health problems were common. A total of 1184 ED presentations by 730 older adolescents were identified. Injury and abdominal pain were the most common complaints for presentations by older adolescents to the ED. The median length of stay in ED was 241 (range: 0-3873) min. More than 60% of the older adolescent ED presentations were triaged urgent or semi-urgent, and 39% of all these presentations resulted in hospital admission. Two-thirds of these older adolescents had a chronic illness, which accounted for 77% of all ED presentations by older adolescents. The history of chronic illness was considered related or relevant in the evaluation and management of over 80% of older adolescents. Of all the ED presentations by older adolescents with chronic illness, only one quarter had transition planning documentation. A high prevalence of chronic illness was found in older adolescents attending the paediatric ED. There was no evidence that behavioural and mental health issues dominated. These findings reflect admission policy. © 2016 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  10. Diffuse Prior Monotonic Likelihood Ratio Test for Evaluation of Fused Image Quality Measures

    DTIC Science & Technology

    2011-02-01

    852–864. [25] W. Mendenhall , R. L. Scheaffer, and D. D. Wackerly, Mathematical Statistics With Applications, 3rd ed. Boston, MA: Duxbury Press, 1986...Professor and holds the Robert W. Wieseman Chaired Research Professorship in Electrical Engi- neering. His research interests include signal

  11. Quantitative analysis of binary polymorphs mixtures of fusidic acid by diffuse reflectance FTIR spectroscopy, diffuse reflectance FT-NIR spectroscopy, Raman spectroscopy and multivariate calibration.

    PubMed

    Guo, Canyong; Luo, Xuefang; Zhou, Xiaohua; Shi, Beijia; Wang, Juanjuan; Zhao, Jinqi; Zhang, Xiaoxia

    2017-06-05

    Vibrational spectroscopic techniques such as infrared, near-infrared and Raman spectroscopy have become popular in detecting and quantifying polymorphism of pharmaceutics since they are fast and non-destructive. This study assessed the ability of three vibrational spectroscopy combined with multivariate analysis to quantify a low-content undesired polymorph within a binary polymorphic mixture. Partial least squares (PLS) regression and support vector machine (SVM) regression were employed to build quantitative models. Fusidic acid, a steroidal antibiotic, was used as the model compound. It was found that PLS regression performed slightly better than SVM regression in all the three spectroscopic techniques. Root mean square errors of prediction (RMSEP) were ranging from 0.48% to 1.17% for diffuse reflectance FTIR spectroscopy and 1.60-1.93% for diffuse reflectance FT-NIR spectroscopy and 1.62-2.31% for Raman spectroscopy. The results indicate that diffuse reflectance FTIR spectroscopy offers significant advantages in providing accurate measurement of polymorphic content in the fusidic acid binary mixtures, while Raman spectroscopy is the least accurate technique for quantitative analysis of polymorphs. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Spectrophotometric Method for Differentiation of Human Skin Melanoma. I. Optical Diffuse Reflection Coefficient

    NASA Astrophysics Data System (ADS)

    Petruk, V. G.; Ivanov, A. P.; Kvaternyuk, S. M.; Barun, V. V.

    2016-03-01

    We have designed an experimental setup, based on two integrating spheres, that lets us measure the optical diffuse reflectance spectra (diffuse reflection coefficient vs. wavelength) of human skin quickly under clinical conditions in vivo. For the wavelength interval 520-1100 nm, we give the values of the diffuse reflection coefficient for healthy tissue, skin with a benign nevus, and skin with a malignant melanoma for a large group of test subjects. We experimentally established a number of wavelengths in the red-near IR region of the spectrum which can be used for early differential diagnosis of nevi and melanoma in patient cancer screening. According to the Kramer-Welch test, the probability of the diffuse reflection coefficient for skin with melanoma and a nevus having different distributions is >0.94, and at many wavelengths it is >0.999. By solving the inverse problem, we estimated the changes in a number of structural and biophysical parameters of the tissue on going from healthy skin to nevus and melanoma. The results obtained can provide a basis for developing a clinical approach to identifying the risk of malignant transformation of the skin before surgery and histological analysis of the tissue.

  13. Tiny Molybdenites Tell Diffusion Tales

    NASA Astrophysics Data System (ADS)

    Stein, H. J.; Hannah, J. L.

    2014-12-01

    Diffusion invokes micron-scale exchange during crystal growth and dissolution in magma chambers on short time-scales. Fundamental to interpreting such data are assumptions on magma-fluid dynamics at all scales. Nevertheless, elemental diffusion profiles are used to estimate time scales for magma storage, eruption, and recharge. An underutilized timepiece to evaluate diffusion and 3D mobility of magmatic fluids is high-precision Re-Os dating of molybdenite. With spatially unique molybdenite samples from a young ore system (e.g., 1 Ma) and a double Os spike, analytical errors of 1-3 ka unambiguously separate events in time. Re-Os ages show that hydrous shallow magma chambers locally recharge and expel Cu-Mo-Au-silica as superimposed stockwork vein networks at time scales less than a few thousand years [1]. Re-Os ages provide diffusion rates controlled by a dynamic crystal mush, accumulation and expulsion of metalliferous fluid, and magma reorganization after explosive crystallization events. Importantly, this approach has broad application far from ore deposits. Here, we use Re-Os dating of molybdenite to assess time scales for generating and diffusing metals through the deep crust. To maximize opportunity for chemical diffusion, we use a continental-scale Sveconorwegian mylonite zone for the study area. A geologically constrained suite of molybdenite samples was acquired from quarry exposures. Molybdenite, previously unreported, is extremely scarce. Tiny but telling molybdenites include samples from like occurrences to assure geologic accuracy in Re-Os ages. Ages range from mid-Mesoproterozoic to mid-Neoproterozoic, and correspond to early metamorphic dehydration of a regionally widespread biotite-rich gneiss, localized melting of gneiss to form cm-m-scale K-feldspar ± quartz pods, development of vapor-rich, vuggy mm stringers that serve as volatile collection surfaces in felsic leucosomes, and low-angle (relative to foliation) cross-cutting cm-scale quartz veins. Re-Os ages and detailed geologic observation document a 200 m.y. history of metal liberation and diffusion through oxidation. [1] Stein, H.J. (2014) Dating and Tracing the History of Ore Formation, in Holland, H.D. & Turekian, K.K. (eds) Treatise on Geochemistry, 2nd Ed. 13: 87-118, Oxford: Elsevier.

  14. Terrorism drill shows ED response plan flaws.

    PubMed

    2005-07-01

    Valuable lessons can be learned by paying attention to your processes and communication equipment during a disaster drill. Did your radios and pagers work adequately? If not, it may be time for a new vendor. Going through the drill helps remind the entire ED staff to funnel all communications and key decisions through the disaster response leader. Make sure to update your disaster response handbook to reflect important lessons learned during the drill.

  15. Stochastic Convection Parameterizations: The Eddy-Diffusivity/Mass-Flux (EDMF) Approach (Invited)

    NASA Astrophysics Data System (ADS)

    Teixeira, J.

    2013-12-01

    In this presentation it is argued that moist convection parameterizations need to be stochastic in order to be realistic - even in deterministic atmospheric prediction systems. A new unified convection and boundary layer parameterization (EDMF) that optimally combines the Eddy-Diffusivity (ED) approach for smaller-scale boundary layer mixing with the Mass-Flux (MF) approach for larger-scale plumes is discussed. It is argued that for realistic simulations stochastic methods have to be employed in this new unified EDMF. Positive results from the implementation of the EDMF approach in atmospheric models are presented.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Basak, Sushovan, E-mail: sushovanbasak@gmail.com; Das, Hrishikesh, E-mail: hrishichem@gmail.com; Pal, Tapan Kumar, E-mail: tkpal.ju@gmail.com

    In order to meet the demand for lighter and more fuel efficient vehicles, a significant attempt is currently being focused toward the substitution of aluminum for steel in the car body structure. It generates vital challenge with respect to the methods of joining to be used for fabrication. However, the conventional fusion joining has its own difficulty owing to formation of the brittle intermetallic phases. In this present study AA6061-T6 of 2 mm and HIF-GA steel sheet of 1 mm thick are metal inert gas (MIG) brazed with 0.8 mm Al–5Si filler wire under three different heat inputs. The effectmore » of the heat inputs on bead geometry, microstructure and joint properties of MIG brazed Al-steel joints were exclusively studied and characterized by X-ray diffraction, field emission scanning electron microscopy (FESEM), electron probe micro analyzer (EPMA) and high resolution transmission electron microscopy (HRTEM) assisted X-ray spectroscopy (EDS) and selective area diffraction pattern. Finally microstructures were correlated with the performance of the joint. Diffusion induced intermetallic thickness measured by FESEM image and concentration profile agreed well with the numerically calculated one. HRTEM assisted EDS study was used to identify the large size FeAl{sub 3} and small size Fe{sub 2}Al{sub 5} type intermetallic compounds at the interface. The growth of these two phases in A2 (heat input: 182 J mm{sup −1}) is attributed to the slower cooling rate with higher diffusion time (~ 61 s) along the interface in comparison to the same for A1 (heat input: 155 J mm{sup −1}) with faster cooling rate and shorter diffusion time (~ 24 s). The joint efficiency as high as 65% of steel base metal is achieved for A2 which is the optimized parameter in the present study. - Highlights: • AA 6061 and HIF-GA could be successfully joined by MIG brazing. • Intermetallics are exclusively studied and characterized by XRD, FESEM and EPMA. • Intermetallic formation by diffusion is worth considering or not. • HRTEM-EDS, SAD pattern identifies the morphologies and size of intermetallics. • A compromise concerning formation of IMC is necessary.« less

  17. Evaluation of diclofenac prodrugs for enhancing transdermal delivery.

    PubMed

    Lobo, Shabbir; Li, Henan; Farhan, Nashid; Yan, Guang

    2014-03-01

    Abstract Objective: The purpose of this study was to evaluate the approach of using diclofenac acid (DA) prodrugs for enhancing transdermal delivery. Methanol diclofenac ester (MD), ethylene glycol diclofenac ester (ED), glycerol diclofenac ester (GD) and 1,3-propylene glycol diclofenac ester (PD) were synthesized and evaluated for their physicochemical properties such as solubilities, octanol/water partition coefficients, stratum corneum/water partition coefficients, hydrolysis rates and bioconversion rates. In vitro fluxes across human epidermal membrane (HEM) in the Franz diffusion cell were determined on DA-, MD-, ED-, GD- and PD-saturated aqueous solutions. The formation of GD and ED led to the prodrugs with higher aqueous solubilities and lower partition coefficients than those of the parent drug. Prodrugs with improved aqueous solubility showed better fluxes across HEM in aqueous solution than that of the parent drug, with GD showing the highest aqueous solubility and also the highest flux. There is a linear relationship between the aqueous solubility and flux for DA, ED and PD, but GD and MD deviated from the linear line. Diclofenac prodrugs with improved hydrophilicity than the parent drug could be utilized for enhancing transdermal diclofenac delivery.

  18. In vivo soft tissue differentiation by diffuse reflectance spectroscopy: preliminary results

    NASA Astrophysics Data System (ADS)

    Zam, Azhar; Stelzle, Florian; Tangermann-Gerk, Katja; Adler, Werner; Nkenke, Emeka; Neukam, Friedrich Wilhelm; Schmidt, Michael; Douplik, Alexandre

    Remote laser surgery does not provide haptic feedback to operate layer by layer and preserve vulnerable anatomical structures like nerve tissue or blood vessels. The aim of this study is identification of soft tissue in vivo by diffuse reflectance spectroscopy to set the base for a feedback control system to enhance nerve preservation in oral and maxillofacial laser surgery. Various soft tissues can be identified by diffuse reflectance spectroscopy in vivo. The results may set the base for a feedback system to prevent nerve damage during oral and maxillofacial laser surgery.

  19. Optical device for thermal diffusivity determination in liquids by reflection of a thermal wave

    NASA Astrophysics Data System (ADS)

    Sánchez-Pérez, C.; De León-Hernández, A.; García-Cadena, C.

    2017-08-01

    In this work, we present a device for determination of the thermal diffusivity using the oblique reflection of a thermal wave within a solid slab that is in contact with the medium to be characterized. By using the reflection near a critical angle under the assumption that thermal waves obey Snell's law of refraction with the square root of the thermal diffusivities, the unknown thermal diffusivity is obtained by simple formulae. Experimentally, the sensor response is measured using the photothermal beam deflection technique within a slab that results in a compact device with no contact of the laser probing beam with the sample. We describe the theoretical basis and provide experimental results to validate the proposed method. We determine the thermal diffusivity of tridistilled water and glycerin solutions with an error of less than 0.5%.

  20. Clinical system model for monitoring the physiological status of jaundice by extracting bilirubin components from skin diffuse reflectance spectra

    NASA Astrophysics Data System (ADS)

    Kumar, Alla S.; Clark, Joseph; Beyette, Fred R., Jr.

    2009-02-01

    Neonatal jaundice is a medical condition which occurs in newborns as a result of an imbalance between the production and elimination of bilirubin. The excess bilirubin in the blood stream diffuses into the surrounding tissue leading to a yellowing of the skin. As the bilirubin levels rise in the blood stream, there is a continuous exchange between the extra vascular bilirubin and bilirubin in the blood stream. Exposure to phototherapy alters the concentration of bilirubin in the vascular and extra vascular regions by causing bilirubin in the skin layers to be broken down. Thus, the relative concentration of extra vascular bilirubin is reduced leading to a diffusion of bilirubin out of the vascular region. Diffuse reflectance spectra from human skin contains physiological and structural information of the skin and nearby tissue. A diffuse reflectance spectrum must be captured before and after blanching in order to isolate the intravascular and extra vascular bilirubin. A new mathematical model is proposed with extra vascular bilirubin concentration taken into consideration along with other optical parameters in defining the diffuse reflectance spectrum from human skin. A nonlinear optimization algorithm has been adopted to extract the optical properties (including bilirubin concentration) from the skin reflectance spectrum. The new system model and nonlinear algorithm have been combined to enable extraction of Bilirubin concentrations within an average error of 10%.

  1. Magnitude of daily energy deficit predicts frequency but not severity of menstrual disturbances associated with exercise and caloric restriction.

    PubMed

    Williams, Nancy I; Leidy, Heather J; Hill, Brenna R; Lieberman, Jay L; Legro, Richard S; De Souza, Mary Jane

    2015-01-01

    We assessed the impact of energy deficiency on menstrual function using controlled feeding and supervised exercise over four menstrual cycles (1 baseline and 3 intervention cycles) in untrained, eumenorrheic women aged 18-30 yr. Subjects were randomized to either an exercising control (EXCON) or one of three exercising energy deficit (ED) groups, i.e., mild (ED1; -8 ± 2%), moderate (ED2; -22 ± 3%), or severe (ED3; -42 ± 3%). Menstrual cycle length and changes in urinary concentrations of estrone-1-glucuronide, pregnanediol glucuronide, and midcycle luteinizing hormone were assessed. Thirty-four subjects completed the study. Weight loss occurred in ED1 (-3.8 ± 0.2 kg), ED2 (-2.8 ± 0.6 kg), and ED3 (-2.6 ± 1.1 kg) but was minimal in EXCON (-0.9 ± 0.7 kg). The overall sum of disturbances (luteal phase defects, anovulation, and oligomenorrhea) was greater in ED2 compared with EXCON and greater in ED3 compared with EXCON AND ED1. The average percent energy deficit was the main predictor of the frequency of menstrual disturbances (f = 10.1, β = -0.48, r(2) = 0.23, P = 0.003) even when weight loss was included in the model. The estimates of the magnitude of energy deficiency associated with menstrual disturbances ranged from -22 (ED2) to -42% (ED3), reflecting an energy deficit of -470 to -810 kcal/day, respectively. This is the first study to demonstrate a dose-response relationship between the magnitude of energy deficiency and the frequency of exercise-related menstrual disturbances; however, the severity of menstrual disturbances was not dependent on the magnitude of energy deficiency. Copyright © 2015 the American Physiological Society.

  2. Reconstructing in-vivo reflectance spectrum of pigmented skin lesion by Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Wang, Shuang; He, Qingli; Zhao, Jianhua; Lui, Harvey; Zeng, Haishan

    2012-03-01

    In dermatology applications, diffuse reflectance spectroscopy has been extensively investigated as a promising tool for the noninvasive method to distinguish melanoma from benign pigmented skin lesion (nevus), which is concentrated with the skin chromophores like melanin and hemoglobin. We carried out a theoretical study to examine melanin distribution in human skin tissue and establish a practical optical model for further pigmented skin investigation. The theoretical simulation was using junctional nevus as an example. A multiple layer skin optical model was developed on established anatomy structures of skin, the published optical parameters of different skin layers, blood and melanin. Monte Carlo simulation was used to model the interaction between excitation light and skin tissue and rebuild the diffuse reflectance process from skin tissue. A testified methodology was adopted to determine melanin contents in human skin based on in vivo diffuse reflectance spectra. The rebuild diffuse reflectance spectra were investigated by adding melanin into different layers of the theoretical model. One of in vivo reflectance spectra from Junctional nevi and their surrounding normal skin was studied by compare the ratio between nevus and normal skin tissue in both the experimental and simulated diffuse reflectance spectra. The simulation result showed a good agreement with our clinical measurements, which indicated that our research method, including the spectral ratio method, skin optical model and modifying the melanin content in the model, could be applied in further theoretical simulation of pigmented skin lesions.

  3. A method of online quantitative interpretation of diffuse reflection profiles of biological tissues

    NASA Astrophysics Data System (ADS)

    Lisenko, S. A.; Kugeiko, M. M.

    2013-02-01

    We have developed a method of combined interpretation of spectral and spatial characteristics of diffuse reflection of biological tissues, which makes it possible to determine biophysical parameters of the tissue with a high accuracy in real time under conditions of their general variability. Using the Monte Carlo method, we have modeled a statistical ensemble of profiles of diffuse reflection coefficients of skin, which corresponds to a wave variation of its biophysical parameters. On its basis, we have estimated the retrieval accuracy of biophysical parameters using the developed method and investigated the stability of the method to errors of optical measurements. We have showed that it is possible to determine online the concentrations of melanin, hemoglobin, bilirubin, oxygen saturation of blood, and structural parameters of skin from measurements of its diffuse reflection in the spectral range 450-800 nm at three distances between the radiation source and detector.

  4. Combination of acoustical radiosity and the image source method.

    PubMed

    Koutsouris, Georgios I; Brunskog, Jonas; Jeong, Cheol-Ho; Jacobsen, Finn

    2013-06-01

    A combined model for room acoustic predictions is developed, aiming to treat both diffuse and specular reflections in a unified way. Two established methods are incorporated: acoustical radiosity, accounting for the diffuse part, and the image source method, accounting for the specular part. The model is based on conservation of acoustical energy. Losses are taken into account by the energy absorption coefficient, and the diffuse reflections are controlled via the scattering coefficient, which defines the portion of energy that has been diffusely reflected. The way the model is formulated allows for a dynamic control of the image source production, so that no fixed maximum reflection order is required. The model is optimized for energy impulse response predictions in arbitrary polyhedral rooms. The predictions are validated by comparison with published measured data for a real music studio hall. The proposed model turns out to be promising for acoustic predictions providing a high level of detail and accuracy.

  5. Optical diffuse reflectance accessory for measurements of skin tissue by near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Marbach, R.; Heise, H. M.

    1995-02-01

    An optimized accessory for measuring the diffuse reflectance spectra of human skin tissue in the near-infrared spectral range is presented. The device includes an on-axis ellipsoidal collecting mirror with efficient illumination optics for small sampling areas of bulky body specimens. The optical design is supported by the results of a Monte Carlo simulation study of the reflectance characteristics of skin tissue. Because the results evolved from efforts to measure blood glucose noninvasively, the main emphasis is placed on the long-wavelength near-infrared range where sufficient penetration depth for radiation into tissue is still available. The accessory is applied for in vivo diffuse reflectance measurements.

  6. TEM Analysis of Diffusion-Bonded Silicon Carbide Ceramics Joined Using Metallic Interlayers

    NASA Technical Reports Server (NTRS)

    Ozaki, T.; Hasegawa, Y.; Tsuda, H.; Mori, S.; Halbig, M. C.; Asthana, R.; Singh, M.

    2017-01-01

    SiC fiber-bonded ceramics (SA-Tyrannohex: SA-THX) diffusion-bonded with TiCu metallic interlayers were investigated. Thin samples of the ceramics were prepared with a focused ion beam (FIB) and the interfacial microstructure of the prepared samples was studied by transmission electron microscopy (TEM) and scanning TEM (STEM). In addition to conventional microstructure observation, for detailed analysis of reaction compounds in diffusion-bonded area, we performed STEM-EDS measurements and selected area electron diffraction (SAD) experiments. The TEM and STEM experiments revealed the diffusion-bonded area was composed of only one reaction layer, which was characterized by TiC precipitates in Cu-Si compound matrix. This reaction layer was in good contact with the SA-THX substrates, and it is concluded that the joint structure led to the excellent bonding strength.

  7. QSAR classification models for the prediction of endocrine disrupting activity of brominated flame retardants.

    PubMed

    Kovarich, Simona; Papa, Ester; Gramatica, Paola

    2011-06-15

    The identification of potential endocrine disrupting (ED) chemicals is an important task for the scientific community due to their diffusion in the environment; the production and use of such compounds will be strictly regulated through the authorization process of the REACH regulation. To overcome the problem of insufficient experimental data, the quantitative structure-activity relationship (QSAR) approach is applied to predict the ED activity of new chemicals. In the present study QSAR classification models are developed, according to the OECD principles, to predict the ED potency for a class of emerging ubiquitary pollutants, viz. brominated flame retardants (BFRs). Different endpoints related to ED activity (i.e. aryl hydrocarbon receptor agonism and antagonism, estrogen receptor agonism and antagonism, androgen and progesterone receptor antagonism, T4-TTR competition, E2SULT inhibition) are modeled using the k-NN classification method. The best models are selected by maximizing the sensitivity and external predictive ability. We propose simple QSARs (based on few descriptors) characterized by internal stability, good predictive power and with a verified applicability domain. These models are simple tools that are applicable to screen BFRs in relation to their ED activity, and also to design safer alternatives, in agreement with the requirements of REACH regulation at the authorization step. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Impact of the Four-Hour Rule in Western Australian hospitals: Trend analysis of a large record linkage study 2002-2013.

    PubMed

    Ngo, Hanh; Forero, Roberto; Mountain, David; Fatovich, Daniel; Man, Wing Nicola; Sprivulis, Peter; Mohsin, Mohammed; Toloo, Sam; Celenza, Antonio; Fitzgerald, Gerard; McCarthy, Sally; Hillman, Ken

    2018-01-01

    In 2009, the Western Australian (WA) Government introduced the Four-Hour Rule (FHR) program. The policy stated that most patients presenting to Emergency Departments (EDs) were to be seen and either admitted, transferred, or discharged within 4 hours. This study utilised de-identified data from five participating hospitals, before and after FHR implementation, to assess the impact of the FHR on several areas of ED functioning. A state (WA) population-based intervention study design, using longitudinal data obtained from administrative health databases via record linkage methodology, and interrupted time series analysis technique. There were 3,214,802 ED presentations, corresponding to 1,203,513 ED patients. After the FHR implementation, access block for patients admitted through ED for all five sites showed a significant reduction of up to 13.2% (Rate Ratio 0.868, 95%CI 0.814, 0.925) per quarter. Rate of ED attendances for most hospitals continued to rise throughout the entire study period and were unaffected by the FHR, except for one hospital. Pattern of change in ED re-attendance rate post-FHR was similar to pre-FHR, but the trend reduced for two hospitals. ED occupancy was reduced by 6.2% per quarter post-FHR for the most 'crowded' ED. ED length of stay and ED efficiency improved in four hospitals and deteriorated in one hospital. Time to being seen by ED clinician and Did-Not-Wait rate improved for some hospitals. Admission rates in post-FHR increased, by up to 1% per quarter, for two hospitals where the pre-FHR trend was decreasing. The FHR had a consistent effect on 'flow' measures: significantly reducing ED overcrowding and access block and enhancing ED efficiency. Time-based outcome measures mostly improved with the FHR. There is some evidence of increased ED attendance, but no evidence of increased ED re-attendance. Effects on patient disposition status were mixed. Overall, this reflects the value of investing resources into the ED/hospital system to improve efficiency and patient experience. Further research is required to illuminate the exact mechanisms of the effects of FHR on the ED and hospital functioning across Australia.

  9. Effects of gender and role selection in cooperative learning groups on science inquiry achievement

    NASA Astrophysics Data System (ADS)

    Affhalter, Maria Geralyn

    An action research project using science inquiry labs and cooperative learning groups examined the effects of same-gender and co-educational classrooms on science achievement and teacher-assigned or self-selected group roles on students' role preferences. Fifty-nine seventh grade students from a small rural school district participated in two inquiry labs in co-educational classrooms or in an all-female classroom, as determined by parents at the beginning of the academic year. Students were assigned to the same cooperative groups for the duration of the study. Pretests and posttests were administered for each inquiry-based science lab. Posttest assessments included questions for student reflection on role assignment and role preference. Instruction did not vary and a female science teacher taught all class sections. The same-gender classroom and co-ed classrooms produced similar science achievement scores on posttests. Students' cooperative group roles, whether teacher-assigned or self-selected, produced similar science achievement scores on posttests. Male and female students shared equally in favorable and unfavorable reactions to their group roles during the science inquiry labs. Reflections on the selection of the leader role revealed a need for females in co-ed groups to be "in charge". When reflecting on her favorite role of leader, one female student in a co-ed group stated, "I like to have people actually listen to me".

  10. History and Flight Devleopment of the Electrodynamic Dust Shield

    NASA Technical Reports Server (NTRS)

    Johansen, Michael R.; Mackey, Paul J.; Hogue, Michael D.; Cox, Rachel E.; Phillips, James R., III; Calle, Carlos I.

    2015-01-01

    The surfaces of the moon, Mars, and that of some asteroids are covered with a layer of dust that may hinder robotic and human exploration missions. During the Apollo missions, for example, lunar dust caused a number of issues including vision obscuration, false instrument readings, contamination, and elevated temperatures. In fact, some equipment neared failure after only 75 hours on the lunar surface due to effects of lunar dust. NASA's Kennedy Space Center has developed an active technology to remove dust from surfaces during exploration missions. The Electrodynamic Dust Shield (EDS), which consists of a series of embedded electrodes in a high dielectric strength substrate, uses a low power, low frequency signal that produces an electric field wave that travels across the surface. This non-uniform electric field generates dielectrophoretic and electrostatic forces capable of moving dust out of these surfaces. Implementations of the EDS have been developed for solar radiators, optical systems, camera lenses, visors, windows, thermal radiators, and fabrics The EDS implementation for transparent applications (solar panels, optical systems, windows, etc.) uses transparent indium tin oxide electrodes on glass or transparent lm. Extensive testing was performed in a roughly simulated lunar environment (one-sixth gravity at 1 mPa atmospheric pressure) with lunar simulant dust. EDS panels over solar radiators showed dust removal that restored solar panel output reaching values very close to their initial output. EDS implementations for thermal radiator protection (metallic spacecraft surfaces with white thermal paint and reflective films) were also extensively tested at similar high vacuum conditions. Reflectance spectra for these types of implementations showed dust removal efficiencies in the 96% to 99% range. These tests indicate that the EDS technology is now at a Technology Readiness Level of 4 to 5. As part of EDS development, a flight version is being prepared for several flight opportunities. The flight version of the EDS will incorporate significantly smaller electronics, with an expected mass and volume of 500 g and 350 cm(exp. 3) respectively. One of the opportunities is an International Space Station (ISS) experiment: Materials for International Space Station Experiment 10 (MISSE-10). This experiment aims to verify the EDS can withstand the harsh environment of space and will look to closely replicate the solar environment experienced on the moon. A second flight opportunity exists to provide an EDS to several companies as part of NASA's Lunar CATALYST program. The current mission concept would fly the EDS on the footpad of one of the Lunar CATALYST vehicles. Dust will likely deposit on the footpad through normal surface rover activities, but also upon landing where lunar dust is expected to be uplifted. To analyze the e effectiveness of the EDS system, photographs of the footpad with one of the spacecrafts onboard cameras are anticipated. If successful in these test flights, the EDS technology will be ready to be used in the protection of actual mission equipment for future NASA and commercial missions to the moon, asteroids, and Mars.

  11. Building capacity in VA to provide emergency gynecology services for women.

    PubMed

    Cordasco, Kristina M; Huynh, Alexis K; Zephyrin, Laurie; Hamilton, Alison B; Lau-Herzberg, Amy E; Kessler, Chad S; Yano, Elizabeth M

    2015-04-01

    Visits to Veterans Administration (VA) emergency departments (EDs) are increasingly being made by women. A 2011 national inventory of VA emergency services for women revealed that many EDs have gaps in their resources and processes for gynecologic emergency care. To guide VA in addressing these gaps, we sought to understand factors acting as facilitators and/or barriers to improving VA ED capacity for, and quality of, emergency gynecology care. Semistructured interviews with VA emergency and women's health key informants. ED directors/providers (n=14), ED nurse managers (n=13), and Women Veteran Program Managers (n=13) in 13 VA facilities. Leadership, staff, space, demand, funding, policies, and community were noted as important factors influencing VA EDs building capacity and improving emergency gynecologic care for women Veterans. These factors are intertwined and cross multiple organizational levels so that each ED's capacity is a reflection not only of its own factors, but also those of its local medical center and non-VA community context as well as VA regional and national trends and policies. Policies and quality improvement initiatives aimed at building VA's emergency gynecologic services for women need to be multifactorial and aimed at multiple organizational levels. Policies need to be flexible to account for wide variations across EDs and their medical center and community contexts. Approaches that build and encourage local leadership engagement, such as evidence-based quality improvement methodology, are likely to be most effective.

  12. Global patterns of evolutionary distinct and globally endangered amphibians and mammals.

    PubMed

    Safi, Kamran; Armour-Marshall, Katrina; Baillie, Jonathan E M; Isaac, Nick J B

    2013-01-01

    Conservation of phylogenetic diversity allows maximising evolutionary information preserved within fauna and flora. The "EDGE of Existence" programme is the first institutional conservation initiative that prioritises species based on phylogenetic information. Species are ranked in two ways: one according to their evolutionary distinctiveness (ED) and second, by including IUCN extinction status, their evolutionary distinctiveness and global endangerment (EDGE). Here, we describe the global patterns in the spatial distribution of priority ED and EDGE species, in order to identify conservation areas for mammalian and amphibian communities. In addition, we investigate whether environmental conditions can predict the observed spatial pattern in ED and EDGE globally. Priority zones with high concentrations of ED and EDGE scores were defined using two different methods. The overlap between mammal and amphibian zones was very small, reflecting the different phylo-biogeographic histories. Mammal ED zones were predominantly found on the African continent and the neotropical forests, whereas in amphibians, ED zones were concentrated in North America. Mammal EDGE zones were mainly in South-East Asia, southern Africa and Madagascar; for amphibians they were in central and south America. The spatial pattern of ED and EDGE was poorly described by a suite of environmental variables. Mapping the spatial distribution of ED and EDGE provides an important step towards identifying priority areas for the conservation of mammalian and amphibian phylogenetic diversity in the EDGE of existence programme.

  13. Moments of disaster response in the emergency department (ED).

    PubMed

    Hammad, Karen S; Arbon, Paul; Gebbie, Kristine; Hutton, Alison

    2017-11-01

    We experience our lives as a series of memorable moments, some good and some bad. Undoubtedly, the experience of participating in disaster response, is likely to stand out as a memorable moment in a nurses' career. This presentation will describe five distinct moments of nursing in the emergency department (ED) during a disaster response. A Hermeneutic Phenomenological approach informed by van Manen underpins the research process. Thirteen nurses from different countries around the world participated in interviews about their experience of working in the ED during a disaster. Thematic analysis resulted in five moments of disaster response which are common to the collective participant experience. The 5 themes emerge as Notification (as a nurse finds out that the ED will be receiving casualties), Waiting (waiting for the patients to arrive to the ED), Patient Arrival (the arrival of the first patients to the ED), Caring for patients (caring for people affected by the disaster) and Reflection (the moment the disaster response comes to an end). This paper provides an in-depth insight into the experience of nursing in the ED during a disaster response which can help generate awareness and inform future disaster preparedness of emergency nurses. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  14. The unique effects of angry and depressive rumination on eating-disorder psychopathology and the mediating role of impulsivity.

    PubMed

    Wang, Shirley B; Borders, Ashley

    2018-04-01

    Negative affect and maladaptive emotion regulation strategies are associated with eating-disorder (ED) psychopathology. Depressive rumination is a maladaptive cognitive style associated with the onset, maintenance, and severity of ED psychopathology among both clinical and nonclinical samples. However, although anger is also strongly associated with ED behaviors, the associations between angry rumination and ED psychopathology, as well as mechanisms of the relationships between rumination and ED psychopathology, remain largely unknown. The current study sought to examine the unique influences of trait depressive and angry rumination on ED psychopathology and whether trait negative urgency (i.e., responding rashly to negative affect) mediated these relationships. Study 1 sampled undergraduate students (N = 119) cross-sectionally and longitudinally (five months), and Study 2 sampled patients with eating disorders (N = 85). All participants completed questionnaires assessing angry rumination, depressive rumination, ED psychopathology, and negative urgency. Angry rumination had consistent indirect effects on ED psychopathology via negative urgency among both clinical and nonclinical samples. However, there was mixed support for the influence of depressive rumination: whereas depressive rumination showed total and indirect effects on ED psychopathology in Study 1 cross-sectional analyses, no total or indirect effects emerged in Study 1 longitudinal analyses or in Study 2. Associations between depressive rumination and ED psychopathology may reflect the strong overlap between angry and depressive rumination. Interventions targeting angry rumination and negative urgency may enhance prevention and treatment of disordered eating across eating disorder diagnosis and severity. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Revisit rates and associated costs after an emergency department encounter: a multistate analysis.

    PubMed

    Duseja, Reena; Bardach, Naomi S; Lin, Grace A; Yazdany, Jinoos; Dean, Mitzi L; Clay, Theodore H; Boscardin, W John; Dudley, R Adams

    2015-06-02

    Return visits to the emergency department (ED) or hospital after an index ED visit strain the health system, but information about rates and determinants of revisits is limited. To describe revisit rates, variation in revisit rates by diagnosis and state, and associated costs. Observational study using the Healthcare Cost and Utilization Project databases. 6 U.S. states. Adults with ED visits between 2006 and 2010. Revisit rates and costs. Within 3 days of an index ED visit, 8.2% of patients had a revisit; 32% of those revisits occurred at a different institution. Revisit rates varied by diagnosis, with skin infections having the highest rate (23.1% [95% CI, 22.3% to 23.9%]). Revisit rates also varied by state. For skin infections, Florida had higher risk-adjusted revisit rates (24.8% [CI, 23.5% to 26.2%]) than Nebraska (10.6% [CI, 9.2% to 12.1%]). In Florida, the only state with complete cost data, total revisit costs for the 19.8% of patients with a revisit within 30 days were 118% of total index ED visit costs for all patients (including those with and without a revisit). Whether a revisit reflects inadequate access to primary care, a planned revisit, the patient's nonadherence to ED recommendations, or poor-quality care at the initial ED visit remains unknown. Revisits after an index ED encounter are more frequent than previously reported, in part because many occur outside the index institution. Among ED patients in Florida, more resources are spent on revisits than on index ED visits. Agency for Healthcare Research and Quality.

  16. Physicians in Postgraduate Training Characteristics and Support of Palliative Sedation for Existential Distress.

    PubMed

    Cripe, Larry D; Perkins, Susan M; Cottingham, Ann; Tong, Yan; Kozak, Mary Ann; Mehta, Rakesh

    2017-09-01

    Palliative sedation for refractory existential distress (PS-ED) is ethically troubling but potentially critical to quality end-of-life (EOL) care. Physicians' in postgraduate training support toward PS-ED is unknown nor is it known how empathy, hope, optimism, or intrinsic religious motivation (IRM) affect their support. These knowledge gaps hinder efforts to support physicians who struggle with patients' EOL care preferences. One hundred thirty-four postgraduate physicians rated their support of PS for refractory physical pain (PS-PP) or PS-ED, ranked the importance of patient preferences in ethically challenging situations, and completed measures of empathy, hope, optimism, and IRM. Predictors of PS-ED and PS-PP support were examined using binary and multinomial logistic regression. Only 22.7% of residents were very supportive of PS-ED, and 82.0% were very supportive of PS-PP. Support for PS-PP or PS-ED did not correlate with levels of empathy, hope, optimism, or IRM; however, for residents with lower IRM, greater optimism was associated with greater PS-ED support. In contrast, among residents with higher IRM, optimism was not associated with PS-ED support. Comparing current results to published surveys, a similar proportion of residents and practicing physicians support PS-ED and PS-PP. In contrast to practicing physicians, however, IRM does not directly influence residents' supportiveness. The interaction between optimism and IRM suggests residents' beliefs and characteristics are salient to their EOL decisions. End-of-life curricula should provide physicians opportunities to reflect on the personal and ethical factors that influence their support for PS-ED.

  17. The Functions of Reflection in High-Stakes Assessment of World Language Teacher Candidates

    ERIC Educational Resources Information Center

    Troyan, Francis J.; Kaplan, Carolyn Shemwell

    2015-01-01

    In response to the call for improving teacher candidates' familiarity with the assessment tasks and format of the edTPA (Hildebrandt & Swanson, 2014), this single case study investigated the reflective writing development of Jena, a K-12 Spanish teacher candidate, and her evolution in a pedagogy that focused on the development of writing two…

  18. Picosecond dynamics of excited singlet states in organic microcrystals: Diffuse reflectance laser photolysis study

    NASA Astrophysics Data System (ADS)

    Ikeda, Noriaki; Koshioka, Masanori; Masuhara, Hiroshi; Yoshihara, Keitaro

    1988-09-01

    Absorption spectra and picosecond dynamics of the singlet exciton states of benzil and p-terphenyl in a microcrystal have been measured for the first time by analyzing the diffuse reflected spectra of the picosecond continuum.

  19. Exploring the Human Element of Computer-Assisted Language Learning: An Iranian Context

    ERIC Educational Resources Information Center

    Fatemi Jahromi, Seyed Abolghasseminits; Salimi, Farimah

    2013-01-01

    Based on various theories of human agency (Ajzen, I. (2005). "Attitudes, personality and behavior" (2nd ed.). London: Open University Press; Davis, F.D. (1989). Perceived usefulness, perceived ease of use, and user acceptance of information technology. "MIS Quarterly", 13, 319-340; Rogers, E.M. (1983). "Diffusion of…

  20. Regression-based model of skin diffuse reflectance for skin color analysis

    NASA Astrophysics Data System (ADS)

    Tsumura, Norimichi; Kawazoe, Daisuke; Nakaguchi, Toshiya; Ojima, Nobutoshi; Miyake, Yoichi

    2008-11-01

    A simple regression-based model of skin diffuse reflectance is developed based on reflectance samples calculated by Monte Carlo simulation of light transport in a two-layered skin model. This reflectance model includes the values of spectral reflectance in the visible spectra for Japanese women. The modified Lambert Beer law holds in the proposed model with a modified mean free path length in non-linear density space. The averaged RMS and maximum errors of the proposed model were 1.1 and 3.1%, respectively, in the above range.

  1. Light distribution modulated diffuse reflectance spectroscopy.

    PubMed

    Huang, Pin-Yuan; Chien, Chun-Yu; Sheu, Chia-Rong; Chen, Yu-Wen; Tseng, Sheng-Hao

    2016-06-01

    Typically, a diffuse reflectance spectroscopy (DRS) system employing a continuous wave light source would need to acquire diffuse reflectances measured at multiple source-detector separations for determining the absorption and reduced scattering coefficients of turbid samples. This results in a multi-fiber probe structure and an indefinite probing depth. Here we present a novel DRS method that can utilize a few diffuse reflectances measured at one source-detector separation for recovering the optical properties of samples. The core of innovation is a liquid crystal (LC) cell whose scattering property can be modulated by the bias voltage. By placing the LC cell between the light source and the sample, the spatial distribution of light in the sample can be varied as the scattering property of the LC cell modulated by the bias voltage, and this would induce intensity variation of the collected diffuse reflectance. From a series of Monte Carlo simulations and phantom measurements, we found that this new light distribution modulated DRS (LDM DRS) system was capable of accurately recover the absorption and scattering coefficients of turbid samples and its probing depth only varied by less than 3% over the full bias voltage variation range. Our results suggest that this LDM DRS platform could be developed to various low-cost, efficient, and compact systems for in-vivo superficial tissue investigation.

  2. Design and validation of a diffuse reflectance and spectroscopic microendoscope with poly(dimethylsioxane)-based phantoms

    PubMed Central

    Greening, Gage J.; Powless, Amy J.; Hutcheson, Joshua A.; Prieto, Sandra P.; Majid, Aneeka A.; Muldoon, Timothy J.

    2015-01-01

    Many cases of epithelial cancer originate in basal layers of tissue and are initially undetected by conventional microendoscopy techniques. We present a bench-top, fiber-bundle microendoscope capable of providing high resolution images of surface cell morphology. Additionally, the microendoscope has the capability to interrogate deeper into material by using diffuse reflectance and broadband diffuse reflectance spectroscopy. The purpose of this multimodal technique was to overcome the limitation of microendoscopy techniques that are limited to only visualizing morphology at the tissue or cellular level. Using a custom fiber optic probe, high resolution surface images were acquired using topical proflavine to fluorescently stain non-keratinized epithelia. A 635 nm laser coupled to a 200 μm multimode fiber delivers light to the sample and the diffuse reflectance signal was captured by a 1 mm image guide fiber. Finally, a tungsten-halogen lamp coupled to a 200 μm multimode fiber delivers broadband light to the sample to acquire spectra at source-detector separations of 374, 729, and 1051 μm. To test the instrumentation, a high resolution proflavine-induced fluorescent image of resected healthy mouse colon was acquired. Additionally, five monolayer poly(dimethylsiloxane)-based optical phantoms with varying absorption and scattering properties were created to acquire diffuse reflectance profiles and broadband spectra. PMID:25983372

  3. Light distribution modulated diffuse reflectance spectroscopy

    PubMed Central

    Huang, Pin-Yuan; Chien, Chun-Yu; Sheu, Chia-Rong; Chen, Yu-Wen; Tseng, Sheng-Hao

    2016-01-01

    Typically, a diffuse reflectance spectroscopy (DRS) system employing a continuous wave light source would need to acquire diffuse reflectances measured at multiple source-detector separations for determining the absorption and reduced scattering coefficients of turbid samples. This results in a multi-fiber probe structure and an indefinite probing depth. Here we present a novel DRS method that can utilize a few diffuse reflectances measured at one source-detector separation for recovering the optical properties of samples. The core of innovation is a liquid crystal (LC) cell whose scattering property can be modulated by the bias voltage. By placing the LC cell between the light source and the sample, the spatial distribution of light in the sample can be varied as the scattering property of the LC cell modulated by the bias voltage, and this would induce intensity variation of the collected diffuse reflectance. From a series of Monte Carlo simulations and phantom measurements, we found that this new light distribution modulated DRS (LDM DRS) system was capable of accurately recover the absorption and scattering coefficients of turbid samples and its probing depth only varied by less than 3% over the full bias voltage variation range. Our results suggest that this LDM DRS platform could be developed to various low-cost, efficient, and compact systems for in-vivo superficial tissue investigation. PMID:27375931

  4. Influence of Acoustic Reflection on the Inertial Cavitation Dose in a Franz Diffusion Cell.

    PubMed

    Robertson, Jeremy; Becker, Sid

    2018-05-01

    The exposure of the skin to low-frequency (20-100 kHz) ultrasound is a well-established method for increasing its permeability to drugs. The mechanism underlying this permeability increase has been found to be inertial cavitation within the coupling fluid. This study investigated the influence of acoustic reflections on the inertial cavitation dose during low-frequency (20 kHz) exposure in an in vitro skin sonoporation setup. This investigation was conducted using a passive cavitation detector that monitored the broadband noise emission within a modified Franz diffusion cell. Two versions of this diffusion cell were employed. One version had acoustic conditions that were similar to those of a standard Franz diffusion cell surrounded by air, whereas the second was designed to greatly reduce the acoustic reflection by submerging the diffusion cell in a water bath. The temperature of the coupling fluid in both setups was controlled using a novel thermoelectric cooling system. At an ultrasound intensity of 13.6 W/cm 2 , the median inertial cavitation dose when the acoustic reflections were suppressed, was found to be only about 15% lower than when reflections were not suppressed. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  5. Spectrophotometric Method for Differentiation of Human Skin Melanoma. II. Diagnostic Characteristics

    NASA Astrophysics Data System (ADS)

    Petruk, V. G.; Ivanov, A. P.; Kvaternyuk, S. M.; Barunb, V. V.

    2016-05-01

    Experimental data on the spectral dependences of the optical diffuse reflection coefficient for skin from different people with melanoma or nevus are presented in the form of the probability density of the diffuse reflection coefficient for the corresponding pigmented lesions. We propose a noninvasive technique for differentiating between malignant and benign tumors, based on measuring the diffuse reflection coefficient for a specific patient and comparing the value obtained with a pre-set threshold. If the experimental result is below the threshold, then it is concluded that the person has melanoma; otherwise, no melanoma is present. As an example, we consider the wavelength 870 nm. We determine the risk of malignant transformation of a nevus (its transition to melanoma) for different measured diffuse reflection coefficients. We have studied the errors in the method, its operating characteristics and probability characteristics as the threshold diffuse reflection coefficient is varied. We find that the diagnostic confidence, sensitivity, specificity, and effectiveness (accuracy) parameters are maximum (>0.82) for a threshold of 0.45-0.47. The operating characteristics for the proposed technique exceed the corresponding parameters for other familiar optical approaches to melanoma diagnosis. Its distinguishing feature is operation at only one wavelength, and consequently implementation of the experimental technique is simplified and made less expensive.

  6. Hyperspectral diffuse reflectance for determination of the optical properties of milk and fruit and vegetable juices

    NASA Astrophysics Data System (ADS)

    Qin, Jianwei; Lu, Renfu

    2005-11-01

    Absorption and reduced scattering coefficients are two fundamental optical properties for turbid biological materials. This paper presents the technique and method of using hyperspectral diffuse reflectance for fast determination of the optical properties of fruit and vegetable juices and milks. A hyperspectral imaging system was used to acquire spatially resolved steady-state diffuse reflectance over the spectral region between 530 and 900 nm from a variety of fruit and vegetable juices (citrus, grapefruit, orange, and vegetable) and milks with different fat levels (full, skim and mixed). The system collected diffuse reflectance in the source-detector separation range from 1.1 to 10.0 mm. The hyperspectral reflectance data were analyzed by using a diffusion theory model for semi-infinite homogeneous media. The absorption and reduced scattering coefficients of the fruit and vegetable juices and milks were extracted by inverse algorithms from the scattering profiles for wavelengths of 530-900 nm. Values of the absorption and reduced scattering coefficient at 650 nm were highly correlated to the fat content of the milk samples with the correlation coefficient of 0.990 and 0.989, respectively. The hyperspectral imaging technique can be extended to the measurement of other liquid and solid foods in which light scattering is dominant.

  7. Design and validation of a diffuse reflectance and spectroscopic microendoscope with poly(dimethylsiloxane)-based phantoms

    NASA Astrophysics Data System (ADS)

    Greening, Gage J.; Powless, Amy J.; Hutcheson, Joshua A.; Prieto, Sandra P.; Majid, Aneeka A.; Muldoon, Timothy J.

    2015-03-01

    Many cases of epithelial cancer originate in basal layers of tissue and are initially undetected by conventional microendoscopy techniques. We present a bench-top, fiber-bundle microendoscope capable of providing high resolution images of surface cell morphology. Additionally, the microendoscope has the capability to interrogate deeper into material by using diffuse reflectance and broadband diffuse reflectance spectroscopy. The purpose of this multimodal technique was to overcome the limitation of microendoscopy techniques that are limited to only visualizing morphology at the tissue or cellular level. Using a custom fiber optic probe, high resolution surface images were acquired using topical proflavine to fluorescently stain non-keratinized epithelia. A 635 nm laser coupled to a 200 μm multimode fiber delivers light to the sample and the diffuse reflectance signal was captured by a 1 mm image guide fiber. Finally, a tungsten-halogen lamp coupled to a 200 μm multimode fiber delivers broadband light to the sample to acquire spectra at source-detector separations of 374, 729, and 1051 μm. To test the instrumentation, a high resolution proflavine-induced fluorescent image of resected healthy mouse colon was acquired. Additionally, five monolayer poly(dimethylsiloxane)-based optical phantoms with varying absorption and scattering properties were created to acquire diffuse reflectance profiles and broadband spectra.

  8. Access to primary care from the perspective of Aboriginal patients at an urban emergency department.

    PubMed

    Browne, Annette J; Smye, Victoria L; Rodney, Patricia; Tang, Sannie Y; Mussell, Bill; O'Neil, John

    2011-03-01

    In this article, we discuss findings from an ethnographic study in which we explored experiences of access to primary care services from the perspective of Aboriginal people seeking care at an emergency department (ED) located in a large Canadian city. Data were collected over 20 months of immersion in the ED, and included participant observation and in-depth interviews with 44 patients triaged as stable and nonurgent, most of whom were living in poverty and residing in the inner city. Three themes in the findings are discussed: (a) anticipating providers' assumptions; (b) seeking help for chronic pain; and (c) use of the ED as a reflection of social suffering. Implications of these findings are discussed in relation to the role of the ED as well as the broader primary care sector in responding to the needs of patients affected by poverty, racialization, and other forms of disadvantage.

  9. NIST High Accuracy Reference Reflectometer-Spectrophotometer

    PubMed Central

    Proctor, James E.; Yvonne Barnes, P.

    1996-01-01

    A new reflectometer-spectrophotometer has been designed and constructed using state-of-the-art technology to enhance optical properties of materials measurements over the ultraviolet, visible, and near-infrared (UV-Vis-NIR) wavelength range (200 nm to 2500 nm). The instrument, Spectral Tri-function Automated Reference Reflectometer (STARR), is capable of measuring specular and diffuse reflectance, bidirectional reflectance distribution function (BRDF) of diffuse samples, and both diffuse and non-diffuse transmittance. Samples up to 30 cm by 30 cm can be measured. The instrument and its characterization are described. PMID:27805081

  10. Wavelength Coded Image Transmission and Holographic Optical Elements.

    DTIC Science & Technology

    1984-08-20

    system has been designed and built for transmitting images of diffusely reflecting objects through optical fibers and displaying those images at a...passive components at the end of a fiber-optic designed to transmit high-resolution images of diffusely imaging system as described in this paper... designing a system for viewing diffusely reflecting The authors are with University of Minnesota. Electrical Engi- objects, one must consider that a

  11. Measurement and Interpretation of Diffuse Scattering in X-Ray Diffraction for Macromolecular Crystallography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wall, Michael E.

    X-ray diffraction from macromolecular crystals includes both sharply peaked Bragg reflections and diffuse intensity between the peaks. The information in Bragg scattering reflects the mean electron density in the unit cells of the crystal. The diffuse scattering arises from correlations in the variations of electron density that may occur from one unit cell to another, and therefore contains information about collective motions in proteins.

  12. Preparation high photocatalytic activity of CdS/halloysite nanotubes (HNTs) nanocomposites with hydrothermal method

    NASA Astrophysics Data System (ADS)

    Xing, Weinan; Ni, Liang; Huo, Pengwei; Lu, Ziyang; Liu, Xinlin; Luo, Yingying; Yan, Yongsheng

    2012-10-01

    A novel nanocatalyst CdS/halloysite nanotubes (HNTs) was synthesized by hydrothermal method with direct growth of CdS nanoparticles on the surface of HNTs. The as-prepared photocatalysts had been characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), UV-vis diffuse reflectance spectra (UV-vis DRS), Fourier transform infrared (FT-IR) and the thermo gravimetric analysis (TGA). The photocatalytic activity of the sample was evaluated by the degradation of tetracycline (TC) under visible light irradiation. Benefit from the excellent properties of CdS and HNTs, the photocatalyst exhibited good photocatalytic activity and stability. In order to find out the optimum synthesis condition to obtain the best photocatalytic activity, a series of experiments were performed with different CdS loading capacity, different sources of sulfide and different hydrothermal temperatures, etc. The best photodegradation rate could reach 93% in 60 min under visible light irradiation. Therefore, the combination of CdS nanoparticles with HNTs endowed this material with a potential use in environmental treatments in industries.

  13. Photo-induced self-cleaning and sterilizing activity of Sm3+ doped ZnO nanomaterials.

    PubMed

    Saif, M; Hafez, H; Nabeel, A I

    2013-01-01

    Highly active samarium doped zinc oxide self-cleaning and biocidal surfaces (x mol% Sm(3+)/ZnO where x=0, 1, 2 and 4 mol%) with crystalline porous structures were synthesized by hydrothermal method. Sm(3+)/ZnO thin films were characterized by X-ray diffraction (XRD), transmission electron microscope (TEM), scanning electron microscope (SEM), energy dispersive spectroscopic (EDS), UV-visible diffuse reflectance and fluorescence (FL) spectroscopy. The combination between doping and hydrothermal treatments significantly altered the morphology of ZnO into rod and plate-like nanoshapes structure and enhanced its absorption and emission of ultraviolet radiation. The photo-activity in term of quantitative determination of the active oxidative species (()OH) produced on the thin film surfaces was evaluated using fluorescent probe method. The results showed that, the hydrothermally treated 2.0 mol% Sm(3+)/ZnO film (S2) is the highly active one. The optical, structural, morphology and photo-activity properties of the highly active thin film (S2) make it promising surface for self-cleaning and sterilizing applications. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Inclusion of Ti and Zr species on clay surfaces and their effect on the interaction with organic molecules

    NASA Astrophysics Data System (ADS)

    Rangel-Rivera, Pedro; Bachiller-Baeza, María Belén; Galindo-Esquivel, Ignacio; Rangel-Porras, Gustavo

    2018-07-01

    The interactions between the clay surface and the organic molecules play an important role in the efficient of these materials in adsorption and catalytic processes. These materials are often modified with the inclusion of other catalytic particles for the purpose of enhancing the activity. In this study, commercial clay K10 was modified with the particles inclusion of titanium and zirconium. The solid surfaces were examined by infrared spectroscopy, scanning electron microscopy (SEM) coupled to an energy-dispersive X-ray spectroscopy device (EDS), and X-ray photoelectron spectroscopy (XPS). Temperature programmed desorption of ammonia (TPD-NH3) and propan-2-ol decomposition test reaction were performed to probe the acid properties. The adsorption of acetic acid, ethanol, and propan-2-ol on the surface of each solid and their thermal stability were studied by diffuse reflectance infrared Fourier transform spectroscopy (DRIFT). Finally, these materials were used in the esterification of acetic acid with penta-1-ol. The real effect over the incorporation of titanium species and zirconium species on clay surface for interacting with the organic molecules was discussed.

  15. IN SITU OXIDATION AND ASSOCIATED MASS-FLUX-REDUCTION/MASS-REMOVAL BEHAVIOR FOR SYSTEMS WITH ORGANIC LIQUID LOCATED IN LOWER-PERMEABILITY SEDIMENTS

    PubMed Central

    Marble, Justin C.; Carroll, Kenneth C.; Janousek, Hilary; Brusseau, Mark L.

    2010-01-01

    The effectiveness of permanganate for in situ chemical oxidation of organic liquid (trichloroethene) trapped in lower-permeability (K) zones located within a higher-permeability matrix was examined in a series of flow-cell experiments. The permanganate solution was applied in both continuous and pulsed-injection modes. Manganese-oxide precipitation, as confirmed by use of SEM-EDS, occurred within, adjacent to, and downgradient of the lower-K zones, reflective of trichloroethene oxidation. During flow interruptions, precipitate formed within the surrounding higher-permeability matrix, indicating diffusive flux of aqueous-phase trichloroethene from the lower-K zones. The impact of permanganate treatment on mass flux behavior was examined by conducting water floods after permanganate injection. The results were compared to those of water-flood control experiments. The amount of water flushing required for complete contaminant mass removal was reduced for all permanganate treatments for which complete removal was characterized. However, the nature of the mass-flux-reduction/mass-removal relationship observed during water flooding varied as a function of the specific permanganate treatment. PMID:20685008

  16. Visible light-harvesting of TiO2 nanotubes array by pulsed laser deposited CdS

    NASA Astrophysics Data System (ADS)

    Bjelajac, Andjelika; Djokic, Veljko; Petrovic, Rada; Socol, Gabiel; Mihailescu, Ion N.; Florea, Ileana; Ersen, Ovidiu; Janackovic, Djordje

    2014-08-01

    Titanium dioxide (TiO2) nanotubes arrays, obtained by anodization technique and annealing, were decorated with CdS using pulsed laser deposition method. Their structural, morphological and chemical characterization was carried out by electron microscopy in scanning (SEM) and transmission (TEM) modes, combined with energy dispersive spectroscopy (EDS) and electron energy loss spectroscopy (EELS). It was demonstrated that the quantity of deposited CdS can be controlled by varying the number of laser pulses. The chemical mapping of the elements of interest was performed using the energy filtered mode of the electron microscope. The results showed that pulse laser deposition is an adequate technique for deposition of CdS inside and between 100 nm wide TiO2 nanotubes. The diffuse reflectance spectroscopy investigation of selected samples proved that the absorption edge of the prepared CdS/TiO2 nanocomposites is significantly extended to the visible range. The corresponding band gaps were determinated from the Tauc plot of transformed Kubelka-Munk function. The band gap reduction of TiO2 nanotubes by pulsed laser deposition of CdS was put in evidence.

  17. Improving the catalytic activity of magnetic Fe3O4/ZnO-CdO/reduced graphene oxide for ultrasonic degradation of the organic pollutants and the green oxidation of olefins

    NASA Astrophysics Data System (ADS)

    Mirzazadeh, Hoda; Lashanizadegan, Maryam

    2018-05-01

    Magnetic Fe3O4/ZnO-CdO/reduced graphene oxide (MFZC/RGO) has been synthesized by simple hydrothermal method. The structure and morphology were investigated by X-ray diffraction (XRD), Transmission electron microscopy (TEM), Scanning electron microscopy (SEM), Energy-dispersive X-ray spectroscopy (EDS), Diffuse reflectance spectroscopy (DRS), Vibrating sample magnetometer (VSM), Raman and Fourier-transform infrared spectroscopy (FTIR). MFZC/RGO was applied as catalyst in degradation of methylene blue (MB), rhodamin B (RhB) and methylorange (MO) under ultrasonic irradiation. Based on the results, excellent degradation efficiencies of MB, RhB and MO (>99%) were achieved within 10, 20 and 20 min, respectively under oxygen flow. Moreover the catalytic property of MFZC/RGO was investigated in oxidation of styrene, α-methyl styrene, cyclohexene and cyclooctene under oxygen flow. In addition, MFZC/RGO can be easily collected and separated by an external magnet. The catalyst displayed negligible loss in activity and selectivity within several successive runs due to super paramagnetism.

  18. Novel Bi/BiOBr/AgBr composite microspheres: Ion exchange synthesis and photocatalytic performance

    NASA Astrophysics Data System (ADS)

    Lyu, Jianchang; Li, Zhenlu; Ge, Ming

    2018-06-01

    Novel Bi/BiOBr/AgBr composite microspheres were prepared by a rational in situ ion exchange reaction between Bi/BiOBr microspheres and AgNO3. The characteristic of the as-obtained ternary microspheres was tested by X-ray diffraction (XRD), energy dispersive X-ray spectrometer (EDS), scanning electron microscope (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), UV-vis diffuse reflectance spectroscopy (UV-vis DRS) and photoluminescence (PL). Under visible light irradiation, Bi/BiOBr/AgBr microspheres exhibited an excellent photocatalytic efficiency for rhodamine B (RhB) degradation, which was about 1.4 and 4.9 times as high as that of Bi/BiOBr and BiOBr/AgBr, demonstrating that the highest separation efficiency of charge carriers in the heterostructured Bi/BiOBr/AgBr. The photocatalytic activity of Bi/BiOBr/AgBr microspheres just exhibited a slight decrease after three consecutive cycles. The photocatalytic mechanism investigation confirmed that the superoxide radicals (O2•-) were the dominant reactive oxygen species for RhB degradation in Bi/BiOBr/AgBr suspension.

  19. Eu2P7X and Ba2As7X (X = Br, I): Chiral double-Zintl salts containing heptapnictotricyclane clusters

    NASA Astrophysics Data System (ADS)

    Dolyniuk, Juli-Anna; Lee, Shannon; Tran, Nhon; Wang, Jian; Wang, Lin-Lin; Kovnir, Kirill

    2018-07-01

    Chiral double Zintl salts present tunable crystal structures with enhanced structural flexibilities and potential for applications requiring chiral control and enantioselectivity. To accompany the chiral Sr2P7I and Sr2P7Br double Zintl salts reported by us previously, six new chiral Zintl salts of the form Ba2-ySryAs7I (y = 0, 0.23, 2), Eu2P7I, Eu2P7Br, and Eu1.3Ba0.7P7Br have been synthesized and characterized by single crystal X-ray diffraction and SEM-EDS analyses. All new compounds crystallize in the Sohncke space group P213 (No. 198) with variations of P73- (heptaphosphanortricyclane) or As73- (heptaarsanortricyclane) clusters surrounded by alkaline-earth or Eu cations and halogen anions. Band structure calculations predict semiconducting properties for all synthesized compounds. Diffuse reflectance UV-vis spectroscopy indicates that Eu2P7I is a direct bandgap semiconductor with Eg of 1.7 eV.

  20. Right service, right place: optimising utilisation of a community nursing service to reduce planned re-presentations to the emergency department

    PubMed Central

    Lawton, Jessica Kirsten; Kinsman, Leigh; Dalton, Lisa; Walsh, Fay; Bryan, Helen; Williams, Sharon

    2017-01-01

    Background Congruent with international rising emergency department (ED) demand, a focus on strategies and services to reduce burden on EDs and improve patient outcomes is necessary. Planned re-presentations of non-urgent patients at a regional Australian hospital exceeded 1200 visits during the 2013–2014 financial year. Planned re-presentations perpetuate demand and signify a lack of alternative services for non-urgent patients. The Community Nursing Enhanced Connections Service (CoNECS) collaboratively evolved between acute care and community services in 2014 to reduce planned ED re-presentations. Objective This study aimed to investigate the evolution and impact of a community nursing service to reduce planned re-presentations to a regional Australian ED and identify enablers and barriers to interventionist effectiveness. Methods A mixed-methods approach evaluated the impact of CoNECS. Data from hospital databases including measured numbers of planned ED re-presentations by month, time of day, age, gender and reason were used to calculate referral rates to CoNECS. These results informed two semistructured focus groups with ED and community nurses. The researchers used a theoretical lens, ‘diffusion of innovation’, to understand how this service could inform future interventions. Results Analyses showed that annual ED planned re-presentations decreased by 43% (527 presentations) after implementation. Three themes emerged from the focus groups. These were right service at the right time, nursing uncertainty and system disconnect and medical disengagement. Conclusions CoNECS reduced overall ED planned re-presentations and was sustained longer than many complex service-level interventions. Factors supporting the service were endorsement from senior administration and strong leadership to drive responsive quality improvement strategies. This study identified a promising alternative service outside the ED, highlighting possibilities for other hospital emergency services aiming to reduce planned re-presentations. PMID:29450293

  1. Fixed bed sorption of phosphorus from wastewater using iron oxide-based media derived from acid mine drainage

    USGS Publications Warehouse

    Sibrell, Philip L.; Tucker, T.W.

    2012-01-01

    Phosphorus (P) releases to the environment have been implicated in the eutrophication of important water bodies worldwide. Current technology for the removal of P from wastewaters consists of treatment with aluminum (Al) or iron (Fe) salts, but is expensive. The neutralization of acid mine drainage (AMD) generates sludge rich in Fe and Al oxides that has hitherto been considered a waste product, but these sludges could serve as an economical adsorption media for the removal of P from wastewaters. Therefore, we have evaluated an AMD-derived media as a sorbent for P in fixed bed sorption systems. The homogenous surface diffusion model (HSDM) was used to analyze fixed bed test data and to determine the value of related sorption parameters. The surface diffusion modulus Ed was found to be a useful predictor of sorption kinetics. Values of Ed < 0.2 were associated with early breakthrough of P, while more desirable S-shaped breakthrough curves resulted when 0.2 < Ed < 0.5. Computer simulations of the fixed bed process with the HSDM confirmed that if Ed was known, the shape of the breakthrough curve could be calculated. The surface diffusion coefficient D s was a critical factor in the calculation of Ed and could be estimated based on the sorption test conditions such as media characteristics, and influent flow rate and concentration. Optimal test results were obtained with a relatively small media particle size (average particle radius 0.028 cm) and resulted in 96 % removal of P from the influent over 46 days of continuous operation. These results indicate that fixed bed sorption of P would be a feasible option for the utilization of AMD residues, thus helping to decrease AMD treatment costs while at the same time ameliorating the impacts of P contamination.

  2. To See the World in a Grain of Sand: Recognizing the Origin of Sand Specimens by Diffuse Reflectance Infrared Fourier Transform Spectroscopy and Multivariate Exploratory Data Analysis

    ERIC Educational Resources Information Center

    Pezzolo, Alessandra De Lorenzi

    2011-01-01

    The diffuse reflectance infrared Fourier transform (DRIFT) spectra of sand samples exhibit features reflecting their composition. Basic multivariate analysis (MVA) can be used to effectively sort subsets of homogeneous specimens collected from nearby locations, as well as pointing out similarities in composition among sands of different origins.…

  3. [The study of aluminium diffuser calibration in the UV].

    PubMed

    Li, Cong; Wang, Yong-Mei; Zhang, Zhong-Mou

    2008-04-01

    A bi-directional reflectance distribution function (BRDF) measurement setup in the ultraviolet spectral range was established. The BRDF of the aluminium diffusers at a given orientation was measured. The relative accuracy of the BRDF measurement is better than 2.5%. The hemispheric reflectance of the aluminium diffusers was measured in the wavelength range from 250 to 650 nm. It increases with the wavelength, and changes about 6% from 300 to 360 nm. It decreases with the time. Since the diffuser was made (about one year ago), from 250 to 300 nm, the peak decrease in the hemispheric reflectance can reach 2.6%, and the average decrease is 1.5%. From 300 to 360 nm, it has an average decrease of 0.9% decrease, and 0.8% when wavelength is longer than 360 nm.

  4. Spectral and geometrical variation of the bidirectional reflectance distribution function of diffuse reflectance standards.

    PubMed

    Ferrero, Alejandro; Rabal, Ana María; Campos, Joaquín; Pons, Alicia; Hernanz, María Luisa

    2012-12-20

    A study on the variation of the spectral bidirectional reflectance distribution function (BRDF) of four diffuse reflectance standards (matte ceramic, BaSO(4), Spectralon, and white Russian opal glass) is accomplished through this work. Spectral BRDF measurements were carried out and, using principal components analysis, its spectral and geometrical variation respect to a reference geometry was assessed from the experimental data. Several descriptors were defined in order to compare the spectral BRDF variation of the four materials.

  5. Synthesis, crystal structure, and photocatalytic activity of a new two-layer Ruddlesden-Popper phase, Li{sub 2}CaTa{sub 2}O{sub 7}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang Zhenhua; Department of Chemistry, University of Science and Technology of China, Hefei, Anhui 230026; Tang Kaibin

    2008-04-15

    A new two-layer Ruddlesden-Popper phase Li{sub 2}CaTa{sub 2}O{sub 7} has been synthesized for the first time. The detailed structure determination of Li{sub 2}CaTa{sub 2}O{sub 7} performed by powder X-ray diffraction (XRD) and electron microscopy (ED) shows that it crystallizes in the space group Fmmm [a{approx}5.5153(1), b{approx}5.4646(1), c{approx}18.2375(3)A]. UV-visible diffuse reflection spectrum of the prepared Li{sub 2}CaTa{sub 2}O{sub 7} indicates that it had absorption in the UV region. The photocatalytic activity of the Li{sub 2}CaTa{sub 2}O{sub 7} powders was evaluated by degradation of RhB molecules in water under ultra visible light irradiation. The results showed that Li{sub 2}CaTa{sub 2}O{sub 7} hasmore » high photocatalytic activity at room temperature. Therefore, the preparation and properties studies of Li{sub 2}CaTa{sub 2}O{sub 7} with a two-layer Ruddlesden-Popper structure suggest potential future applications in photocatalysis. - Graphical abstract: Crystal structure of a two-layer Ruddlesden-Popper phase Li{sub 2}CaTa{sub 2}O{sub 7} A new two-layer Ruddlesden-Popper phase Li{sub 2}CaTa{sub 2}O{sub 7} has been synthesized for the first time. Li{sub 2}CaTa{sub 2}O{sub 7} crystallizes in the space group Fmmm determined by powder X-ray and electron diffraction. UV-visible diffuse reflection spectra and the photocatalytic degradation of RhB molecules in water under ultra visible light irradiation show that Li{sub 2}CaTa{sub 2}O{sub 7} is a potential material in photocatalysis.« less

  6. Comparison of the Radiative Two-Flux and Diffusion Approximations

    NASA Technical Reports Server (NTRS)

    Spuckler, Charles M.

    2006-01-01

    Approximate solutions are sometimes used to determine the heat transfer and temperatures in a semitransparent material in which conduction and thermal radiation are acting. A comparison of the Milne-Eddington two-flux approximation and the diffusion approximation for combined conduction and radiation heat transfer in a ceramic material was preformed to determine the accuracy of the diffusion solution. A plane gray semitransparent layer without a substrate and a non-gray semitransparent plane layer on an opaque substrate were considered. For the plane gray layer the material is semitransparent for all wavelengths and the scattering and absorption coefficients do not vary with wavelength. For the non-gray plane layer the material is semitransparent with constant absorption and scattering coefficients up to a specified wavelength. At higher wavelengths the non-gray plane layer is assumed to be opaque. The layers are heated on one side and cooled on the other by diffuse radiation and convection. The scattering and absorption coefficients were varied. The error in the diffusion approximation compared to the Milne-Eddington two flux approximation was obtained as a function of scattering coefficient and absorption coefficient. The percent difference in interface temperatures and heat flux through the layer obtained using the Milne-Eddington two-flux and diffusion approximations are presented as a function of scattering coefficient and absorption coefficient. The largest errors occur for high scattering and low absorption except for the back surface temperature of the plane gray layer where the error is also larger at low scattering and low absorption. It is shown that the accuracy of the diffusion approximation can be improved for some scattering and absorption conditions if a reflectance obtained from a Kubelka-Munk type two flux theory is used instead of a reflection obtained from the Fresnel equation. The Kubelka-Munk reflectance accounts for surface reflection and radiation scattered back by internal scattering sites while the Fresnel reflection only accounts for surface reflections.

  7. An algorithm for emulsion stability simulations: account of flocculation, coalescence, surfactant adsorption and the process of Ostwald ripening.

    PubMed

    Urbina-Villalba, German

    2009-03-01

    The first algorithm for Emulsion Stability Simulations (ESS) was presented at the V Conferencia Iberoamericana sobre Equilibrio de Fases y Diseño de Procesos [Luis, J.; García-Sucre, M.; Urbina-Villalba, G. Brownian Dynamics Simulation of Emulsion Stability In: Equifase 99. Libro de Actas, 1(st) Ed., Tojo J., Arce, A., Eds.; Solucion's: Vigo, Spain, 1999; Volume 2, pp. 364-369]. The former version of the program consisted on a minor modification of the Brownian Dynamics algorithm to account for the coalescence of drops. The present version of the program contains elaborate routines for time-dependent surfactant adsorption, average diffusion constants, and Ostwald ripening.

  8. Fatal yellow fever in a traveler returning from Venezuela, 1999.

    PubMed

    2000-04-14

    On September 28, 1999, a previously healthy 48-year-old man from California sought care at a local emergency department (ED) and was hospitalized with a 2-day history of fever (102 F [38.9 C]), chills, headache, photophobia, diffuse myalgias, joint pains, nausea, vomiting, constipation, upper abdominal discomfort, and general weakness. On September 26, he had returned from a 10-day trip to Venezuela. On September 29, an infectious disease physician from the ED contacted the Marin County Health Department (MCHD) about the patient's symptoms; MCHD reported his illness to the California Department of Health Services (CDHS) as a suspected case of viral hemorrhagic fever. This report describes the investigation of the case.

  9. What makes community engagement effective?: Lessons from the Eliminate Dengue Program in Queensland Australia.

    PubMed

    Kolopack, Pamela A; Parsons, Janet A; Lavery, James V

    2015-04-01

    Worldwide, more than 40% of the population is at risk from dengue and recent estimates suggest that up to 390 million dengue infections are acquired every year. The Eliminate Dengue (ED) Program is investigating the use of Wolbachia-infected, transmission-compromised, mosquitoes to reduce dengue transmission. Previous introductions of genetically-modified strategies for dengue vector control have generated controversy internationally by inadequately engaging host communities. Community Engagement (CE) was a key component of the ED Program's initial open release trials in Queensland Australia. Their approach to CE was perceived as effective by the ED team's senior leadership, members of its CE team, and by its funders, but if and why this was the case was unclear. We conducted a qualitative case study of the ED Program's approach to CE to identify and critically examine its components, and to explain whether and how these efforts contributed to the support received by stakeholders. In-depth semi-structured interviews were conducted with 24 participants with a range of experiences and perspectives related to the ED Program's CE activities. Our analytic approach combined techniques of grounded theory and qualitative description. The ED Program's approach to CE reflected four foundational features: 1) enabling conditions; 2) leadership; 3) core commitments and guiding values; and 4) formative social science research. These foundations informed five key operational practices: 1) building the CE team; 2) integrating CE into management practices; 3) discerning the community of stakeholders; 4) establishing and maintaining a presence in the community; and 5) socializing the technology and research strategy. We also demonstrate how these practices contributed to stakeholders' willingness to support the trials. Our case study has identified, and explained the functional relationships among, the critical features of the ED Program's approach to CE. It has also illuminated how these features were meaningful to stakeholders and contributed to garnering support within the host communities for the open-release trials. Our findings reveal how translating ethical intentions into effective action is more socially complex than is currently reflected in the CE literature. Because our case study delineates the critical features of the ED Program's approach to CE, it can serve as a framework for other programs to follow when designing their own strategies. And because the findings outline a theory of change for CE, it can also serve as a starting point for developing an evaluation framework for CE.

  10. Effect of substrate dislocations on the Hg in-diffusion in CdZnTe substrates used for HgCdTe epilayer growth

    NASA Astrophysics Data System (ADS)

    Kumar, Shiv; Kapoor, A. K.; Nagpal, A.; Sharma, S.; Verma, D.; Kumar, A.; Raman, R.; Basu, P. K.

    2006-12-01

    Chemical-etched HgCdTe epilayers grown onto CdZnTe substrates have been studied using defect etching and EDS on cleaved (1 1 0) face. Formation of etch pits and mercury (Hg) in-diffusion into CZT substrate has been correlated with the substrate quality i.e. the presence of dislocations around second phase inclusions. That the Hg in-diffusion takes place through these dislocations is authenticated by the presence of Te-inclusions in substrates where large density of etch pits are revealed after chemical etching. X-ray rocking curve measurements were carried out to reveal crystalline quality of the substrates. FTIR spectroscopy indicates low transmission values and absence of interference fringes in MCT epilayers with large Hg diffusion. Hg diffusion into CZT substrate upto 25 μm in samples with low FWHM values and upto 250 μm in samples with multiple peaks and high FWHM values was observed.

  11. Sodium Chloride Diffusion during Muscle Salting Evidenced by Energy-Dispersive X-ray Spectroscopy Imaging.

    PubMed

    Filgueras, Rénata; Peyrin, Frédéric; Vénien, Annie; Hénot, Jean Marc; Astruc, Thierry

    2016-01-27

    To better understand the relationship between the muscle structure and NaCl transfers in meat, we used energy-dispersive X-ray spectroscopy (EDS) coupled with scanning electron microscopy (SEM) to analyze brined and dry-salted rat muscles. The muscles were freeze-dried to avoid the delocalization of soluble ions that happens in regular dehydration through a graded series of ethanol. Na and Cl maps were superimposed on SEM images to combine the muscle structure and NaCl diffusion. Brining causes rapid diffusion of NaCl through the tissue. Most brine diffuses in a linear front from the muscle surface, but a small proportion enters through the perimysium network. The muscle area penetrated by brine shows heterogeneous patterns of NaCl retention, with some connective tissue islets containing more NaCl than other parts of perimysium. NaCl penetration is considerably slower after dry salting than after brining.

  12. In vivo burn diagnosis by camera-phone diffuse reflectance laser speckle detection.

    PubMed

    Ragol, S; Remer, I; Shoham, Y; Hazan, S; Willenz, U; Sinelnikov, I; Dronov, V; Rosenberg, L; Bilenca, A

    2016-01-01

    Burn diagnosis using laser speckle light typically employs widefield illumination of the burn region to produce two-dimensional speckle patterns from light backscattered from the entire irradiated tissue volume. Analysis of speckle contrast in these time-integrated patterns can then provide information on burn severity. Here, by contrast, we use point illumination to generate diffuse reflectance laser speckle patterns of the burn. By examining spatiotemporal fluctuations in these time-integrated patterns along the radial direction from the incident point beam, we show the ability to distinguish partial-thickness burns in a porcine model in vivo within the first 24 hours post-burn. Furthermore, our findings suggest that time-integrated diffuse reflectance laser speckle can be useful for monitoring burn healing over time post-burn. Unlike conventional diffuse reflectance laser speckle detection systems that utilize scientific or industrial-grade cameras, our system is designed with a camera-phone, demonstrating the potential for burn diagnosis with a simple imager.

  13. In vivo burn diagnosis by camera-phone diffuse reflectance laser speckle detection

    PubMed Central

    Ragol, S.; Remer, I.; Shoham, Y.; Hazan, S.; Willenz, U.; Sinelnikov, I.; Dronov, V.; Rosenberg, L.; Bilenca, A.

    2015-01-01

    Burn diagnosis using laser speckle light typically employs widefield illumination of the burn region to produce two-dimensional speckle patterns from light backscattered from the entire irradiated tissue volume. Analysis of speckle contrast in these time-integrated patterns can then provide information on burn severity. Here, by contrast, we use point illumination to generate diffuse reflectance laser speckle patterns of the burn. By examining spatiotemporal fluctuations in these time-integrated patterns along the radial direction from the incident point beam, we show the ability to distinguish partial-thickness burns in a porcine model in vivo within the first 24 hours post-burn. Furthermore, our findings suggest that time-integrated diffuse reflectance laser speckle can be useful for monitoring burn healing over time post-burn. Unlike conventional diffuse reflectance laser speckle detection systems that utilize scientific or industrial-grade cameras, our system is designed with a camera-phone, demonstrating the potential for burn diagnosis with a simple imager. PMID:26819831

  14. Polarization properties and microfacet-based modelling of white, grey and coloured matte diffuse reflection standards

    NASA Astrophysics Data System (ADS)

    Quast, T.; Schirmacher, A.; Hauer, K.-O.; Koo, A.

    2018-02-01

    To elucidate the influence of polarization in diffuse reflectometry, we performed a series of measurements in several bidirectional geometries and determined the Stokes parameters of the diffusely reflected radiation. Different types of matte reflection standards were used, including several common white standards and ceramic colour standards. The dependence of the polarization on the sample type, wavelength and geometry have been studied systematically, the main influence factors have been identified: The effect is largest at large angles of incidence or detection and at wavelengths where the magnitude of the reflectance is small. The results for the colour standards have been modelled using a microfacet-based reflection theory which is derived from the well-known model of Torrance and Sparrow. Although the theory is very simple and only has three free parameters, the agreement with the measured data is very good, all essential features of the data can be reproduced by the model.

  15. From Vulcanian explosions to sustained explosive eruptions: The role of diffusive mass transfer in conduit flow dynamics

    NASA Astrophysics Data System (ADS)

    Mason, R. M.; Starostin, A. B.; Melnik, O. E.; Sparks, R. S. J.

    2006-05-01

    Magmatic explosive eruptions are influenced by mass transfer processes of gas diffusion into bubbles caused by decompression. Melnik and Sparks [Melnik, O.E., Sparks, R.S.J. 2002, Modelling of conduit flow dynamic during explosive activity at Soufriere Hills Volcano, Montserrat. In: Druitt, T.H., Kokelaar, B.P. (eds). The Eruption of Soufriere Hills Volcano, Montserrat, from 1995 to 1999. Geological Society, London, Memoirs, 21, 307-317] proposed two end member cases corresponding to complete equilibrium and complete disequilibrium. In the first case, diffusion is fast enough to maintain the system near equilibrium and a long-lived explosive eruption develops. In the latter case, pre-existing bubbles expand under conditions of explosive eruption and decompression, but diffusive gas transfer is negligible. This leads to a much shorter eruption. Here we develop this model to consider the role of mass transfer by investigating transient flows at the start of an explosive eruption triggered by a sudden decompression. The simulations reveal a spectrum of behaviours from sustained to short-lived highly non-equilibrium Vulcanian-style explosions lasting a few tens of seconds, through longer lasting eruptions that can be sustained for tens of minutes and finally to eruptions that can last hours or even days. Behaviour is controlled by a mass-transfer parameter, ω, which equals n*2/3D, where n* is the bubble number density and D is the diffusivity. The parameter ω is expected to vary between 10 - 5 and 1 s - 1 in nature and reflects a time-scale for efficient diffusion. The spectrum of model behaviours is consistent with variations in styles of explosive eruptions of silicic volcanoes. In the initial stages peak discharges occur over 10-20 s and then decline to low discharges. If a critical bubble overpressure is assumed to be the criterion for fragmentation then fragmentation may stop and start several times in the declining period causing several pulses of high-intensity discharge. For the cases of strong disequilibria, the fluxes can decrease to negligible values where other processes, such as gas escape through permeable magma, prevents explosive conditions becoming re-established so that explosive activity stops and dome growth can start. For cases closer to the equilibrium the eruption can evolve towards a quasi-steady sustained flow, never declining sufficiently for gas escape to become dominant.

  16. A Narrative Inquiry into the Experience of Negotiating the Dominant Stories of Physical Education: Living, Telling, Re-Telling and Re-Living

    ERIC Educational Resources Information Center

    Casey, Ashley; Schaefer, Lee

    2016-01-01

    This paper explores the tensions that surfaced as a teacher of physical education (PE) shifted his "stories to live by" [Clandinin, D. J., & Connelly, F. M. (1999). "Storying and restorying ourselves: Narrative and reflection." In A. Y. Chen & J. Van Maanen (Eds.), "The reflective spin: Case studies of teachers in…

  17. Illusory conjunctions in simultanagnosia: coarse coding of visual feature location?

    PubMed

    McCrea, Simon M; Buxbaum, Laurel J; Coslett, H Branch

    2006-01-01

    Simultanagnosia is a disorder characterized by an inability to see more than one object at a time. We report a simultanagnosic patient (ED) with bilateral posterior infarctions who produced frequent illusory conjunctions on tasks involving form and surface features (e.g., a red T) and form alone. ED also produced "blend" errors in which features of one familiar perceptual unit appeared to migrate to another familiar perceptual unit (e.g., "RO" read as "PQ"). ED often misread scrambled letter strings as a familiar word (e.g., "hmoe" read as "home"). Finally, ED's success in reporting two letters in an array was inversely related to the distance between the letters. These findings are consistent with the hypothesis that ED's illusory reflect coarse coding of visual feature location that is ameliorated in part by top-down information from object and word recognition systems; the findings are also consistent, however, with Treisman's Feature Integration Theory. Finally, the data provide additional support for the claim that the dorsal parieto-occipital cortex is implicated in the binding of visual feature information.

  18. Validity of the Electrodiffusion Model for Calculating Conductance of Simple Ion Channels.

    PubMed

    Pohorille, Andrew; Wilson, Michael A; Wei, Chenyu

    2017-04-20

    We examine the validity and utility of the electrodiffusion (ED) equation, i.e., the generalized Nernst-Planck equation, to characterize, in combination with molecular dynamics, the electrophysiological behavior of simple ion channels. As models, we consider three systems-two naturally occurring channels formed by α-helical bundles of peptaibols, trichotoxin, and alamethicin, and a synthetic, hexameric channel, formed by a peptide that contains only leucine and serine. All these channels mediate transport of potassium and chloride ions. Starting with equilibrium properties, such as the potential of mean force experienced by an ion traversing the channel and diffusivity, obtained from molecular dynamics simulations, the ED equation can be used to determine the full current-voltage dependence with modest or no additional effort. The potential of mean force can be obtained not only from equilibrium simulations, but also, with comparable accuracy, from nonequilibrium simulations at a single voltage. The main assumptions underlying the ED equation appear to hold well for the channels and voltages studied here. To expand the utility of the ED equation, we examine what are the necessary and sufficient conditions for Ohmic and nonrectifying behavior and relate deviations from this behavior to the shape of the ionic potential of mean force.

  19. Construction and evaluation of a self rating scale for stress-induced Exhaustion Disorder, the Karolinska Exhaustion Disorder Scale

    PubMed Central

    Besèr, Aniella; Sorjonen, Kimmo; Wahlberg, Kristina; Peterson, Ulla; Nygren, Åke; Åsberg, Marie

    2014-01-01

    Prolonged stress (≥ six months) may cause a condition which has been named exhaustion disorder (ED) with ICD-10 code F43.8. ED is characterised by exhaustion, cognitive problems, poor sleep and reduced tolerance to further stress. ED can cause long term disability and depressive symptoms may develop. The aim was to construct and evaluate a self-rating scale, the Karolinska Exhaustion Disorder Scale (KEDS), for the assessment of ED symptoms. A second aim was to examine the relationship between self-rated symptoms of ED, depression, and anxiety using KEDS and the Hospital Anxiety and Depression Scale (HAD). Items were selected based on their correspondence to criteria for ED as formulated by the Swedish National Board of Health and Welfare (NBHW), with seven response alternatives in a Likert-format. Self-ratings performed by 317 clinically assessed participants were used to analyse the scale’s psychometric properties. KEDS consists of nine items with a scale range of 0–54. Receiver operating characteristics analysis demonstrated that a cut-off score of 19 was accompanied by high sensitivity and specificity (each above 95%) in the discrimination between healthy subjects and patients with ED. Reliability was satisfactory and confirmatory factor analysis revealed that ED, depression and anxiety are best regarded as different phenomena. KEDS may be a useful tool in the assessment of symptoms of Exhaustion Disorder in clinical as well as research settings. There is evidence that the symptom clusters of ED, anxiety and depression, respectively, reflect three different underlying dimensions. PMID:24236500

  20. Investigating the scale-adaptivity of a shallow cumulus parameterization scheme with LES

    NASA Astrophysics Data System (ADS)

    Brast, Maren; Schemann, Vera; Neggers, Roel

    2017-04-01

    In this study we investigate the scale-adaptivity of a new parameterization scheme for shallow cumulus clouds in the gray zone. The Eddy-Diffusivity Multiple Mass-Flux (or ED(MF)n ) scheme is a bin-macrophysics scheme, in which subgrid transport is formulated in terms of discretized size densities. While scale-adaptivity in the ED-component is achieved using a pragmatic blending approach, the MF-component is filtered such that only the transport by plumes smaller than the grid size is maintained. For testing, ED(MF)n is implemented in a large-eddy simulation (LES) model, replacing the original subgrid-scheme for turbulent transport. LES thus plays the role of a non-hydrostatic testing ground, which can be run at different resolutions to study the behavior of the parameterization scheme in the boundary-layer gray zone. In this range convective cumulus clouds are partially resolved. We find that at high resolutions the clouds and the turbulent transport are predominantly resolved by the LES, and the transport represented by ED(MF)n is small. This partitioning changes towards coarser resolutions, with the representation of shallow cumulus clouds becoming exclusively carried by the ED(MF)n. The way the partitioning changes with grid-spacing matches the results of previous LES studies, suggesting some scale-adaptivity is captured. Sensitivity studies show that a scale-inadaptive ED component stays too active at high resolutions, and that the results are fairly insensitive to the number of transporting updrafts in the ED(MF)n scheme. Other assumptions in the scheme, such as the distribution of updrafts across sizes and the value of the area fraction covered by updrafts, are found to affect the location of the gray zone.

  1. Artificial neural networks for retrieving absorption and reduced scattering spectra from frequency-domain diffuse reflectance spectroscopy at short source-detector separation

    PubMed Central

    Chen, Yu-Wen; Chen, Chien-Chih; Huang, Po-Jung; Tseng, Sheng-Hao

    2016-01-01

    Diffuse reflectance spectroscopy (DRS) based on the frequency-domain (FD) technique has been employed to investigate the optical properties of deep tissues such as breast and brain using source to detector separation up to 40 mm. Due to the modeling and system limitations, efficient and precise determination of turbid sample optical properties from the FD diffuse reflectance acquired at a source-detector separation (SDS) of around 1 mm has not been demonstrated. In this study, we revealed that at SDS of 1 mm, acquiring FD diffuse reflectance at multiple frequencies is necessary for alleviating the influence of inevitable measurement uncertainty on the optical property recovery accuracy. Furthermore, we developed artificial neural networks (ANNs) trained by Monte Carlo simulation generated databases that were capable of efficiently determining FD reflectance at multiple frequencies. The ANNs could work in conjunction with a least-square optimization algorithm to rapidly (within 1 second), accurately (within 10%) quantify the sample optical properties from FD reflectance measured at SDS of 1 mm. In addition, we demonstrated that incorporating the steady-state apparatus into the FD DRS system with 1 mm SDS would enable obtaining broadband absorption and reduced scattering spectra of turbid samples in the wavelength range from 650 to 1000 nm. PMID:27446671

  2. Vanadium diffusion coating on HT-9 cladding for mitigating the fuel cladding chemical interactions

    NASA Astrophysics Data System (ADS)

    Lo, Wei-Yang; Yang, Yong

    2014-08-01

    Fuel cladding chemical interaction (FCCI) has been identified as one of the crucial issues for developing Ferritic/Martensitic (F/M) stainless steel claddings for metallic fuels in a fast reactor. The anticipated elevated temperature and high neutron flux can significantly aggravate the FCCI, in terms of formation of inter-diffusion and lower melting point eutectic phases. To mitigate the FCCI, vanadium carbide coating as a diffusion barrier was deposited on the HT-9 substrate using a pack cementation diffusion coating (PCDC) method, and the processing temperature was optimized down to 730 °C. A solid metallurgical bonding between the coating layer and substrate was achieved, and the coating is free from through depth cracks. The microstructural characterizations using SEM and TEM show a nanostructured grain structure. EDS/WDS and XRD analysis confirm the phase of coating layer as V2C. Diffusion couple tests at 660 °C for 100 h demonstrate that V2C layer with a thickness of less than 5 μm can effectively eliminate the inter-diffusion between the lanthanide cerium and HT-9 steel.

  3. Impact of the Four-Hour Rule in Western Australian hospitals: Trend analysis of a large record linkage study 2002-2013

    PubMed Central

    Ngo, Hanh; Forero, Roberto; Mountain, David; Fatovich, Daniel; Man, Wing Nicola; Sprivulis, Peter; Mohsin, Mohammed; Toloo, Sam; Celenza, Antonio; Fitzgerald, Gerard; McCarthy, Sally; Hillman, Ken

    2018-01-01

    Background In 2009, the Western Australian (WA) Government introduced the Four-Hour Rule (FHR) program. The policy stated that most patients presenting to Emergency Departments (EDs) were to be seen and either admitted, transferred, or discharged within 4 hours. This study utilised de-identified data from five participating hospitals, before and after FHR implementation, to assess the impact of the FHR on several areas of ED functioning. Methods A state (WA) population-based intervention study design, using longitudinal data obtained from administrative health databases via record linkage methodology, and interrupted time series analysis technique. Findings There were 3,214,802 ED presentations, corresponding to 1,203,513 ED patients. After the FHR implementation, access block for patients admitted through ED for all five sites showed a significant reduction of up to 13.2% (Rate Ratio 0.868, 95%CI 0.814, 0.925) per quarter. Rate of ED attendances for most hospitals continued to rise throughout the entire study period and were unaffected by the FHR, except for one hospital. Pattern of change in ED re-attendance rate post-FHR was similar to pre-FHR, but the trend reduced for two hospitals. ED occupancy was reduced by 6.2% per quarter post-FHR for the most ‘crowded’ ED. ED length of stay and ED efficiency improved in four hospitals and deteriorated in one hospital. Time to being seen by ED clinician and Did-Not-Wait rate improved for some hospitals. Admission rates in post-FHR increased, by up to 1% per quarter, for two hospitals where the pre-FHR trend was decreasing. Conclusions The FHR had a consistent effect on ‘flow’ measures: significantly reducing ED overcrowding and access block and enhancing ED efficiency. Time-based outcome measures mostly improved with the FHR. There is some evidence of increased ED attendance, but no evidence of increased ED re-attendance. Effects on patient disposition status were mixed. Overall, this reflects the value of investing resources into the ED/hospital system to improve efficiency and patient experience. Further research is required to illuminate the exact mechanisms of the effects of FHR on the ED and hospital functioning across Australia. PMID:29538401

  4. SeaWiFS long-term solar diffuser reflectance trend analysis

    NASA Astrophysics Data System (ADS)

    Eplee, Robert E., Jr.; Patt, Frederick S.; Barnes, Robert A.; McClain, Charles R.

    2006-08-01

    The NASA Ocean Biology Processing Group's Calibration and Validation (Cal/Val) Team implemented daily solar calibrations of SeaWiFS to look for step-function changes in the instrument response and has used these calibrations to supplement the monthly lunar calibrations in monitoring the radiometric stability of SeaWiFS during its first year of on-orbit operations. The Team has undertaken an analysis of the mission-long solar calibration time series, with the lunar-derived radiometric corrections over time applied, to assess the long-term degradation of the solar diffuser reflectance over nine years on orbit. The SeaWiFS diffuser is an aluminum plate coated with YB71 paint. The bidirectional reflectance distribution function of the diffuser was not fully characterized before launch, so the Cal/Val Team has implemented a regression of the solar incidence angles and the drift in the node of the satellite's orbit against the diffuser time series to correct for solar incidence angle effects. An exponential function with a time constant of 200 days yields the best fit to the diffuser time series. The decrease in diffuser reflectance over the mission is wavelength-dependent, ranging from 9% in the blue (412 nm) to 5% in the red and near infrared (670-865 nm). The degradation of diffuser reflctance is similar to that observed for SeaWiFS radiometric response itself from lunar calibration time series for bands 1-5 (412-555 nm), though the magnitude of the change is four times larger for the diffuser. Evidently, the same optical degradation process has affected both the telescope optics and the solar diffuser in the blue and green. The Cal/Val Team has developed a methodology for computing the signal-to-noise ratio (SNR) for SeaWiFS on orbit from the diffuser time series. The on-orbit change in the SNR for each band over the nine-year mission is less than 7%. The on-orbit performance of the SeaWiFS solar diffuser should offer insight into the long-term on-orbit performance of solar diffusers on other instruments, such as MODIS, VIIRS, and ABI.

  5. Determination of Structural and Morphological Parameters of Human Bulbar Conjunctiva from Optical Diffuse Reflectance Spectra

    NASA Astrophysics Data System (ADS)

    Lisenko, S. A.; Firago, V. A.; Kugeiko, M. M.; Kubarko, A. I.

    2016-09-01

    We have developed a method for on-the-fl y retrieval of the volume concentration of blood vessels, the average diameter of the blood vessels, the blood oxygenation level, and the molar concentrations of chromophores in the bulbar conjunctiva from its diffuse reflectance spectra, measured when the radiation delivery and detection channels are spatially separated. The relationship between the diffuse reflectance spectrum of the conjunctiva and its unknown parameters is described in terms of an analytical model, constructed on the basis of a highly accurate approximation analog of the Monte Carlo method. We have studied the effect of localization of hemoglobin in erythrocytes and localization of erythrocytes in the blood vessels on the power of the retrieval of structural and morphological parameters for the conjunctiva. We developed a device for obtaining video images of the conjunctiva and contactless measurements of its diffuse reflectance spectrum. By comparing simulated diffuse reflectance spectra of the conjunctiva with the experimental measurements, we established a set of chromophores which must be taken into account in the model for reproducing the experimental data within the measurement error. We observed absorption bands for neuroglobin in the experimental spectra, and provided a theoretical basis for the possibility of determining its absolute concentrations in the conjunctiva. We have shown that our method can detect low bilirubin concentrations in blood.

  6. Magnitude of daily energy deficit predicts frequency but not severity of menstrual disturbances associated with exercise and caloric restriction

    PubMed Central

    Leidy, Heather J.; Hill, Brenna R.; Lieberman, Jay L.; Legro, Richard S.; Souza, Mary Jane De

    2014-01-01

    We assessed the impact of energy deficiency on menstrual function using controlled feeding and supervised exercise over four menstrual cycles (1 baseline and 3 intervention cycles) in untrained, eumenorrheic women aged 18–30 yr. Subjects were randomized to either an exercising control (EXCON) or one of three exercising energy deficit (ED) groups, i.e., mild (ED1; −8 ± 2%), moderate (ED2; −22 ± 3%), or severe (ED3; −42 ± 3%). Menstrual cycle length and changes in urinary concentrations of estrone-1-glucuronide, pregnanediol glucuronide, and midcycle luteinizing hormone were assessed. Thirty-four subjects completed the study. Weight loss occurred in ED1 (−3.8 ± 0.2 kg), ED2 (−2.8 ± 0.6 kg), and ED3 (−2.6 ± 1.1 kg) but was minimal in EXCON (−0.9 ± 0.7 kg). The overall sum of disturbances (luteal phase defects, anovulation, and oligomenorrhea) was greater in ED2 compared with EXCON and greater in ED3 compared with EXCON AND ED1. The average percent energy deficit was the main predictor of the frequency of menstrual disturbances (f = 10.1, β = −0.48, r2 = 0.23, P = 0.003) even when weight loss was included in the model. The estimates of the magnitude of energy deficiency associated with menstrual disturbances ranged from −22 (ED2) to −42% (ED3), reflecting an energy deficit of −470 to −810 kcal/day, respectively. This is the first study to demonstrate a dose-response relationship between the magnitude of energy deficiency and the frequency of exercise-related menstrual disturbances; however, the severity of menstrual disturbances was not dependent on the magnitude of energy deficiency. PMID:25352438

  7. Tick bite and Lyme disease-related emergency department encounters in New Hampshire, 2010-2014.

    PubMed

    Daly, E R; Fredette, C; Mathewson, A A; Dufault, K; Swenson, D J; Chan, B P

    2017-12-01

    Lyme disease (LD) is a common tick-borne disease in New Hampshire (NH). While LD is a reportable condition and cases are counted for public health surveillance, many more people receive care for tick bites or diagnoses of LD than are reflected in surveillance data. NH's emergency department (ED) data system was queried for tick bite and LD-related encounters. Chief complaint text was queried for words related to LD or tick bites. International Classification of Diseases 9th Revision (ICD-9) codes were queried for the LD diagnosis code (088.81). Emergency department patient data were matched to reportable disease data to determine the proportion of ED patients reported to the health department as a suspected LD case. Data were analysed to calculate frequencies for key demographic and reporting characteristics. From 2010 to 2014, 13,615 tick bite or LD-related ED encounters were identified in NH, with most due to tick bites (76%). Of 3,256 patients with a LD-related ED encounter, 738 (23%) were reported to the health department as a suspected LD case. The geographic distribution of ED patients was similar to reported LD cases; however, the regions of the state that experienced higher rates of ED encounters were different than the regions that observed higher rates of reported LD cases. Seasonal distribution of ED encounters peaked earlier than reported LD cases with a second peak in the fall. While age and sex distribution was similar among ED patients and reported LD cases, the rates for children 5 years and younger and adults 65 years and older were greater for ED encounters. Patients frequently visit the ED to seek care for tick bites and suspected LD. Results of ED data analyses can be used to target education, in particular for ED providers and the public through timely distribution of evidence-based educational materials and training programmes. © 2017 Blackwell Verlag GmbH.

  8. Parameterization and sensitivity analyses of a radiative transfer model for remote sensing plant canopies

    NASA Astrophysics Data System (ADS)

    Hall, Carlton Raden

    A major objective of remote sensing is determination of biochemical and biophysical characteristics of plant canopies utilizing high spectral resolution sensors. Canopy reflectance signatures are dependent on absorption and scattering processes of the leaf, canopy properties, and the ground beneath the canopy. This research investigates, through field and laboratory data collection, and computer model parameterization and simulations, the relationships between leaf optical properties, canopy biophysical features, and the nadir viewed above-canopy reflectance signature. Emphasis is placed on parameterization and application of an existing irradiance radiative transfer model developed for aquatic systems. Data and model analyses provide knowledge on the relative importance of leaves and canopy biophysical features in estimating the diffuse absorption a(lambda,m-1), diffuse backscatter b(lambda,m-1), beam attenuation alpha(lambda,m-1), and beam to diffuse conversion c(lambda,m-1 ) coefficients of the two-flow irradiance model. Data sets include field and laboratory measurements from three plant species, live oak (Quercus virginiana), Brazilian pepper (Schinus terebinthifolius) and grapefruit (Citrus paradisi) sampled on Cape Canaveral Air Force Station and Kennedy Space Center Florida in March and April of 1997. Features measured were depth h (m), projected foliage coverage PFC, leaf area index LAI, and zenith leaf angle. Optical measurements, collected with a Spectron SE 590 high sensitivity narrow bandwidth spectrograph, included above canopy reflectance, internal canopy transmittance and reflectance and bottom reflectance. Leaf samples were returned to laboratory where optical and physical and chemical measurements of leaf thickness, leaf area, leaf moisture and pigment content were made. A new term, the leaf volume correction index LVCI was developed and demonstrated in support of model coefficient parameterization. The LVCI is based on angle adjusted leaf thickness Ltadj, LAI, and h (m). Its function is to translate leaf level estimates of diffuse absorption and backscatter to the canopy scale allowing the leaf optical properties to directly influence above canopy estimates of reflectance. The model was successfully modified and parameterized to operate in a canopy scale and a leaf scale mode. Canopy scale model simulations produced the best results. Simulations based on leaf derived coefficients produced calculated above canopy reflectance errors of 15% to 18%. A comprehensive sensitivity analyses indicated the most important parameters were beam to diffuse conversion c(lambda, m-1), diffuse absorption a(lambda, m-1), diffuse backscatter b(lambda, m-1), h (m), Q, and direct and diffuse irradiance. Sources of error include the estimation procedure for the direct beam to diffuse conversion and attenuation coefficients and other field and laboratory measurement and analysis errors. Applications of the model include creation of synthetic reflectance data sets for remote sensing algorithm development, simulations of stress and drought on vegetation reflectance signatures, and the potential to estimate leaf moisture and chemical status.

  9. Diffuse characteristics study of laser target board using Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Yang, Pengling; Wu, Yong; Wang, Zhenbao; Tao, Mengmeng; Wu, Junjie; Wang, Ping; Yan, Yan; Zhang, Lei; Feng, Gang; Zhu, Jinghui; Feng, Guobin

    2013-05-01

    In this paper, Torrance-Sparrow and Oren-Nayar model is adopt to study diffuse characteristics of laser target board. The model which based on geometric optics, assumes that rough surfaces are made up of a series of symmetric V-groove cavities with different slopes at microscopic level. The distribution of the slopes of the V-grooves are modeled as beckman distribution function, and every microfacet of the V-groove cavity is assumed to behave like a perfect mirror, which means the reflected ray follows Fresnel law at the microfacet. The masking and shadowing effects of rough surface are also taken into account through geometric attenuation factor. Monte Carlo method is used to simulate the diffuse reflectance distribution of the laser target board with different materials and processing technology, and all the calculated results are verified by experiment. It is shown that the profile of bidirectional reflectance distribution curve is lobe-shaped with the maximum lies along the mirror reflection direction. The width of the profile is narrower for a lower roughness value, and broader for a higher roughness value. The refractive index of target material will also influence the intensity and distribution of diffuse reflectance of laser target surface.

  10. Dual-modality optical biopsy of glioblastomas multiforme with diffuse reflectance and fluorescence: ex vivo retrieval of optical properties

    NASA Astrophysics Data System (ADS)

    Du Le, Vinh Nguyen; Provias, John; Murty, Naresh; Patterson, Michael S.; Nie, Zhaojun; Hayward, Joseph E.; Farrell, Thomas J.; McMillan, William; Zhang, Wenbin; Fang, Qiyin

    2017-02-01

    Glioma itself accounts for 80% of all malignant primary brain tumors, and glioblastoma multiforme (GBM) accounts for 55% of such tumors. Diffuse reflectance and fluorescence spectroscopy have the potential to discriminate healthy tissues from abnormal tissues and therefore are promising noninvasive methods for improving the accuracy of brain tissue resection. Optical properties were retrieved using an experimentally evaluated inverse solution. On average, the scattering coefficient is 2.4 times higher in GBM than in low grade glioma (LGG), and the absorption coefficient is 48% higher. In addition, the ratio of fluorescence to diffuse reflectance at the emission peak of 460 nm is 2.6 times higher for LGG while reflectance at 650 nm is 2.7 times higher for GBM. The results reported also show that the combination of diffuse reflectance and fluorescence spectroscopy could achieve sensitivity of 100% and specificity of 90% in discriminating GBM from LGG during ex vivo measurements of 22 sites from seven glioma specimens. Therefore, the current technique might be a promising tool for aiding neurosurgeons in determining the extent of surgical resection of glioma and, thus, improving intraoperative tumor identification for guiding surgical intervention.

  11. Dual-modality optical biopsy of glioblastomas multiforme with diffuse reflectance and fluorescence: ex vivo retrieval of optical properties.

    PubMed

    Du Le, Vinh Nguyen; Provias, John; Murty, Naresh; Patterson, Michael S; Nie, Zhaojun; Hayward, Joseph E; Farrell, Thomas J; McMillan, William; Zhang, Wenbin; Fang, Qiyin

    2017-02-01

    Glioma itself accounts for 80% of all malignant primary brain tumors, and glioblastoma multiforme (GBM) accounts for 55% of such tumors. Diffuse reflectance and fluorescence spectroscopy have the potential to discriminate healthy tissues from abnormal tissues and therefore are promising noninvasive methods for improving the accuracy of brain tissue resection. Optical properties were retrieved using an experimentally evaluated inverse solution. On average, the scattering coefficient is 2.4 times higher in GBM than in low grade glioma (LGG), and the absorption coefficient is 48% higher. In addition, the ratio of fluorescence to diffuse reflectance at the emission peak of 460 nm is 2.6 times higher for LGG while reflectance at 650 nm is 2.7 times higher for GBM. The results reported also show that the combination of diffuse reflectance and fluorescence spectroscopy could achieve sensitivity of 100% and specificity of 90% in discriminating GBM from LGG during ex vivo measurements of 22 sites from seven glioma specimens. Therefore, the current technique might be a promising tool for aiding neurosurgeons in determining the extent of surgical resection of glioma and, thus, improving intraoperative tumor identification for guiding surgical intervention.

  12. Determination of the optical properties of semi-infinite turbid media from frequency-domain reflectance close to the source.

    PubMed

    Kienle, A; Patterson, M S

    1997-09-01

    We investigate theoretically the errors in determining the reduced scattering and absorption coefficients of semi-infinite turbid media from frequency-domain reflectance measurements made at small distances between the source and the detector(s). The errors are due to the uncertainties in the measurement of the phase, the modulation and the steady-state reflectance as well as to the diffusion approximation which is used as a theoretical model to describe light propagation in tissue. Configurations using one and two detectors are examined for the measurement of the phase and the modulation and for the measurement of the phase and the steady-state reflectance. Three solutions of the diffusion equation are investigated. We show that measurements of the phase and the steady-state reflectance at two different distances are best suited for the determination of the optical properties close to the source. For this arrangement the errors in the absorption coefficient due to typical uncertainties in the measurement are greater than those resulting from the application of the diffusion approximation at a modulation frequency of 200 MHz. A Monte Carlo approach is also examined; this avoids the errors due to the diffusion approximation.

  13. Online high-speed NIR diffuse-reflectance imaging spectroscopy in food quality monitoring

    NASA Astrophysics Data System (ADS)

    Driver, Richard D.; Didona, Kevin

    2009-05-01

    The use of hyperspectral technology in the NIR for food quality monitoring is discussed. An example of the use of hyperspectral diffuse reflectance scanning and post-processing with a chemometric model shows discrimination between four pharmaceutical samples comprising Aspirin, Acetaminophen, Vitamin C and Vitamin D.

  14. Further laboratory study of the diffuse reflectance spectra of frosts occurring on astronomical objects

    NASA Technical Reports Server (NTRS)

    Glaser, F. M.

    1976-01-01

    Oligoclase and bloedite, two mined samples, have been investigated, and the diffuse reflectance spectra are presented. These data are for powdered material, 50 microns to 5 microns size mixture, cooled to 160 K. The reflectivity of the oligoclase sample was also measured at room temperature, about 290 K, and the results at these two temperatures do indicate some tentative differences. A frost of ordinary water was prepared and its spectral reflectance is presented. This result compares reasonably well with measurements made by other investigators.

  15. The Use Of Fluorescence Quenching To Measure Oxygen Concentration

    NASA Astrophysics Data System (ADS)

    Cox, M. E.; Dunn, B.

    1986-01-01

    The method of fluorescence quenching is used to measure the concentration of molecular oxygen. The method is rapid, reversible, and does not consume oxygen. The method may provide the basis for a unique biomedical sensor. The key to developing such a device lies in the choice of a fluorophor/polymer composite matrix having the desired optical and transport properties. Experimental results will be presented for certain parameters essential for assessing device development. The properties of interest include the kinetics of fluorescence quenching, the biomolecular rate constants, the temperature dependence of oxygen solubility and diffusivity in the composite matrix, and the oxygen diffusion coefficient. Poly(dimethyl siloxane) [PDMS] was chosen as the polymer host because it is biocompatible, hydrophobic, has a high diffusivity for the simple gases, and is easily bonded to fused silica. 9,10-diphenyl anthracene [9,10-D] was selected since it is readily soluble in a number of organic solvents, has an excitation spectrum in the near UV, an emission spectrum in the visible, a long fluorescence lifetime, and a high quantum yield. When incorporated into PDMS, the optical spectra of 9,10-D does not alter appreciably. The response time of the device is determined by the solution/diffusion kinetics of oxygen in PDMS. The solubility of oxygen in PDMS decreases with increasing temperature and an enthalpy of solution of off = -3.0 kcal/mole. (1) The diffusion of oxyzen in PDMS is found to obey an Arrhenius relation over the temperature range of 5'C to 450C with D = Do exp (-ED/RT) (2) where Do = 0.115 cm2/s (3) and ED = 4.77 kcal/mole. (4) Results of these studies indicate that an appropriate device, based on a fluorophor/polymer composite, for the measurement of oxygen concentration should be sensitive over those ranges which are important for physiological monitoring.

  16. Assessment of Refueling Hose Visibility: Post-Cleaning Evaluation

    DTIC Science & Technology

    2013-10-01

    Cott, H.P., and Kinkade, R.G. (Eds.), Human Engineering Guide to Equipment Design. Washington, DC: GPO. F-35 Gen 5 HMDS spec for minimum...spectral band sensors: visible, near IR, and short-wave IR. These images will be captured for each of the samples set up for both the geometries...Contrast Ratio Near IR Black Reflectance White Reflectance Contrast Ratio Short Wave IR Black

  17. Limitations of the commonly used simplified laterally uniform optical fiber probe-tissue interface in Monte Carlo simulations of diffuse reflectance

    PubMed Central

    Naglič, Peter; Pernuš, Franjo; Likar, Boštjan; Bürmen, Miran

    2015-01-01

    Light propagation models often simplify the interface between the optical fiber probe tip and tissue to a laterally uniform boundary with mismatched refractive indices. Such simplification neglects the precise optical properties of the commonly used probe tip materials, e.g. stainless steel or black epoxy. In this paper, we investigate the limitations of the laterally uniform probe-tissue interface in Monte Carlo simulations of diffuse reflectance. In comparison to a realistic probe-tissue interface that accounts for the layout and properties of the probe tip materials, the simplified laterally uniform interface is shown to introduce significant errors into the simulated diffuse reflectance. PMID:26504647

  18. [Application of near-infrared diffuse reflectance spectroscopy to the detection and identification of transgenic corn].

    PubMed

    Rui, Yu-kui; Luo, Yun-bo; Huang, Kun-lun; Wang, Wei-min; Zhang, Lu-da

    2005-10-01

    With the rapid development of the GMO, more and more GMO food has been pouring into the market. Much attention has been paid to GMO labeling under the controversy of GMO safety. Transgenic corns and their parents were scanned by continuous wave of near infrared diffuse reflectance spectroscopy range of 12000-4000 cm(-1); the resolution was 4 cm(-1); scanning was carried out for 64 times; BP algorithm was applied for data processing. The GMO food was easily resolved. Near-infrared diffuse reflectance spectroscopy is unpolluted and inexpensive compared with PCR and ELISA, so it is a very promising detection method for GMO food.

  19. Transfer matrix method for four-flux radiative transfer.

    PubMed

    Slovick, Brian; Flom, Zachary; Zipp, Lucas; Krishnamurthy, Srini

    2017-07-20

    We develop a transfer matrix method for four-flux radiative transfer, which is ideally suited for studying transport through multiple scattering layers. The model predicts the specular and diffuse reflection and transmission of multilayer composite films, including interface reflections, for diffuse or collimated incidence. For spherical particles in the diffusion approximation, we derive closed-form expressions for the matrix coefficients and show remarkable agreement with numerical Monte Carlo simulations for a range of absorption values and film thicknesses, and for an example multilayer slab.

  20. Selective mode excitation in finite size plasma crystals by diffusely reflected laser light

    NASA Astrophysics Data System (ADS)

    Schablinski, Jan; Block, Dietmar

    2015-02-01

    The possibility to use diffuse reflections of a laser beam to exert a force on levitating dust particles is studied experimentally. Measurements and theoretical predictions are found to be in good agreement. Further, the method is applied to test the selective excitation of breathing-like modes in finite dust clusters.

  1. Diffuse-reflectance fourier-transform mid-infrared spectroscopy as a method of characterizing changes in soil organic matter

    USDA-ARS?s Scientific Manuscript database

    Diffuse-Reflectance Fourier-Transform Mid-Infrared Spectroscopy (MidIR) can identify the presence of important organic functional groups in soil organic matter (SOM). Soils contain myriad organic and inorganic components that absorb in the MidIR so spectral interpretation needs to be validated in or...

  2. Can written information material help to increase treatment motivation in patients with erectile dysfunction? A survey of 1188 men.

    PubMed

    Günzler, C; Kriston, L; Stodden, V; Leiber, C; Berner, M M

    2007-01-01

    Although erectile dysfunction (ED) prevalence is high, patients and physicians often have problems discussing this issue. This study examines whether written information material increases motivation to seek treatment in patients with ED. For the study, persons were able to order information material about sexual problems within the context of a public campaign. From a total of 70,000 responders, 8000 persons were asked to fill out an epidemiological questionnaire. The response rate yielded 18.4%, the data of 1188 men with ED were analyzed. As a result of the information material, 28.3% of the untreated men intended to seek treatment and 38.5% of the men who had not spoken with their physician about their problem, planned to do so now. Nearly all responders were satisfied with the information material. These data reflect the usefulness of written information for men with ED. It not only serves as an informational source for patients but may also encourage them to seek treatment.

  3. Construction and evaluation of a self rating scale for stress-induced exhaustion disorder, the Karolinska Exhaustion Disorder Scale.

    PubMed

    Besèr, Aniella; Sorjonen, Kimmo; Wahlberg, Kristina; Peterson, Ulla; Nygren, Ake; Asberg, Marie

    2014-02-01

    Prolonged stress (≥ six months) may cause a condition which has been named exhaustion disorder (ED) with ICD-10 code F43.8. ED is characterised by exhaustion, cognitive problems, poor sleep and reduced tolerance to further stress. ED can cause long term disability and depressive symptoms may develop. The aim was to construct and evaluate a self-rating scale, the Karolinska Exhaustion Disorder Scale (KEDS), for the assessment of ED symptoms. A second aim was to examine the relationship between self-rated symptoms of ED, depression, and anxiety using KEDS and the Hospital Anxiety and Depression Scale (HAD). Items were selected based on their correspondence to criteria for ED as formulated by the Swedish National Board of Health and Welfare (NBHW), with seven response alternatives in a Likert-format. Self-ratings performed by 317 clinically assessed participants were used to analyse the scale's psychometric properties. KEDS consists of nine items with a scale range of 0-54. Receiver operating characteristics analysis demonstrated that a cut-off score of 19 was accompanied by high sensitivity and specificity (each above 95%) in the discrimination between healthy subjects and patients with ED. Reliability was satisfactory and confirmatory factor analysis revealed that ED, depression and anxiety are best regarded as different phenomena. KEDS may be a useful tool in the assessment of symptoms of Exhaustion Disorder in clinical as well as research settings. There is evidence that the symptom clusters of ED, anxiety and depression, respectively, reflect three different underlying dimensions. © 2013 The Authors. Scandinavian Journal of Psychology published by Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  4. Erectile dysfunction and phosphodiesterase type 5 inhibitor use: associations with sexual activities, function and satisfaction in a population sample of older men.

    PubMed

    Lee, D M; Nazroo, J; Pendleton, N

    2015-07-01

    The objective of this study was to examine the association between sexual activities, problems and satisfaction, and ED and PDE5 inhibitor (PDE5i) use. A nationally representative sample of men (n=2612) aged 51-87 years from the English Longitudinal Study of Ageing completed an in-depth Sexual Relationships and Activities Questionnaire. Associations between ED and/or PDE5i use and sexual outcomes were explored using logistic regression models adjusted for age, health and lifestyle factors. PDE5i use in the preceding 3 months was reported by a total of 191 (7%) men, whereas 542 (21%) reported ED but no PDE5i use (untreated ED). Compared with men without ED, PDE5i users were more likely to be sexually active and report more frequent sexual intercourse. Men with untreated ED reported the lowest frequency of sexual activities. Compared with men without ED, both PDE5i users and those with untreated ED were more likely to report being concerned about their level of sexual desire, frequency of sexual activities, erectile function, waking erections and orgasmic experience. PDE5i users were also more concerned about and dissatisfied with their overall sex life than men without ED. This population-based study shows that while PDE5i use is associated with improved sexual functioning, this is not equally reflected in decreased levels of concern and dissatisfaction with their overall sexual health. Clinicians should be aware of this disparity between functional gains and continuing sexual concerns and dissatisfaction, and, where appropriate, offer psychosexual counselling as an adjunct to PDE5i medication.

  5. Retarded head growth and neurocognitive development in infants of mothers with a history of eating disorders: longitudinal cohort study.

    PubMed

    Koubaa, S; Hällström, T; Hagenäs, L; Hirschberg, A L

    2013-10-01

    To characterise early growth and neurocognitive development in children of mothers with a history of eating disorders (ED). A longitudinal cohort study. Child-care centres in Stockholm, Sweden. Children born to mothers with previous ED (n = 47) (24 anorexia nervosa, 20 bulimia nervosa, 3 unspecified ED), and controls (n = 65). Mean values and standard deviation scores of weight and height from birth to 5 years of age and head circumference up to 18 months of age were compared between groups. Neurocognitive development was studied at the age of 5 years by the validated parent questionnaire Five to Fifteen. Head growth and neurocognitive development. We previously reported that mothers with a history of ED conceived infants with lower birthweight and head circumference than controls. At 3 months of age, body mass index (BMI) was no longer reduced but mean head circumferences of the children born to mothers with ED were smaller throughout the observation period. Similarly, the longitudinal results of the standard deviation scores of head circumference showed a significant overall group effect with lower levels in both subgroups of ED (anorexia nervosa and bulimia nervosa). The children of the ED mothers also had significantly higher Five to Fifteen scores than controls, reflecting difficulties in language skills. Head circumference at birth correlated with language skills in the children of mothers with ED. Children of mothers with previous ED demonstrated an early catch-up in BMI, but the average head circumference continued to be delayed until at least 18 months of age. The reduced head growth was related to delayed neurocognitive development. © 2013 RCOG.

  6. Choosing the best method to estimate the energy density of a population using food purchase data.

    PubMed

    Wrieden, W L; Armstrong, J; Anderson, A S; Sherriff, A; Barton, K L

    2015-04-01

    Energy density (ED) is a measure of the energy content of a food component or diet relative to a standard unit of weight. Widespread variation in ED assessment methodologies exist. The present study aimed to explore the feasibility of calculating the ED of the Scottish diet using UK food purchase survey data and to identify the most appropriate method for calculating ED for use in the development of a Scottish Dietary Goal that captures any socioeconomic differences. Energy density was calculated using five different methods [food; food and milk; food, milk and energy containing (non-alcoholic) beverages; food, milk and all non-alcoholic beverages; and all food and beverages]. ED of the Scottish diet was estimated for each of the ED methods and data were examined by deprivation category. Mean ED varied from 409 to 847 kJ 100 g(-1) depending on the method used. ED values calculated from food (847 kJ 100 g(-1) ) and food and milk (718 kJ 100 g(-1) ) were most comparable to other published data, with the latter being a more accurate reflection of all food consumed. For these two methods, there was a significant gradient between the most and least deprived quintiles (892-807 and 737-696 kJ 100 g(-1) for food and food and milk, respectively). Because the World Cancer Research Fund recommendations are based on ED from food and milk, it was considered prudent to use this method for policy purposes and for future monitoring work of the Scottish Diet to ensure consistency of reporting and comparability with other published studies. © 2014 The British Dietetic Association Ltd.

  7. Interface morphology of Mo/Si multilayer systems with varying Mo layer thickness studied by EUV diffuse scattering.

    PubMed

    Haase, Anton; Soltwisch, Victor; Braun, Stefan; Laubis, Christian; Scholze, Frank

    2017-06-26

    We investigate the influence of the Mo-layer thickness on the EUV reflectance of Mo/Si mirrors with a set of unpolished and interface-polished Mo/Si/C multilayer mirrors. The Mo-layer thickness is varied in the range from 1.7 nm to 3.05 nm. We use a novel combination of specular and diffuse intensity measurements to determine the interface roughness throughout the multilayer stack and do not rely on scanning probe measurements at the surface only. The combination of EUV and X-ray reflectivity measurements and near-normal incidence EUV diffuse scattering allows to reconstruct the Mo layer thicknesses and to determine the interface roughness power spectral density. The data analysis is conducted by applying a matrix method for the specular reflection and the distorted-wave Born approximation for diffuse scattering. We introduce the Markov-chain Monte Carlo method into the field in order to determine the respective confidence intervals for all reconstructed parameters. We unambiguously detect a threshold thickness for Mo in both sample sets where the specular reflectance goes through a local minimum correlated with a distinct increase in diffuse scatter. We attribute that to the known appearance of an amorphous-to-crystallization transition at a certain thickness threshold which is altered in our sample system by the polishing.

  8. NaYF{sub 4}:Er,Yb/Bi{sub 2}MoO{sub 6} core/shell nanocomposite: A highly efficient visible-light-driven photocatalyst utilizing upconversion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Yuanyuan; Wang, Wenzhong, E-mail: wzwang@mail.sic.ac.cn; Sun, Songmei

    2014-04-01

    Highlights: • Design and synthesis of NaYF{sub 4}:Er,Yb/Bi{sub 2}MoO{sub 6} based on upconversion. • NaYF{sub 4}:Er,Yb/Bi{sub 2}MoO{sub 6} nanocomposite was prepared for the first time. • Core–shell structure benefits the properties. • Upconversion contributed to the enhanced photocatalytic activity. • Helps to understand the functionality of new type photocatalysts. - Abstract: NaYF{sub 4}:Er,Yb/Bi{sub 2}MoO{sub 6} core/shell nanocomposite was designed and prepared for the first time based on upconversion. The products were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), high resolution TEM (HRTEM), energy dispersive X-ray spectroscopy (EDS) and diffuse reflectance spectra (DRS). The results revealed that the as-synthesizedmore » NaYF{sub 4}:Er,Yb/Bi{sub 2}MoO{sub 6} consisted of spheres with a core diameter of about 26 nm and a shell diameter of around 6 nm. The core was upconversion illuminant NaYF{sub 4}:Er,Yb and the shell was Bi{sub 2}MoO{sub 6} around the core, which was confirmed by EDS. The NaYF{sub 4}:Er,Yb/Bi{sub 2}MoO{sub 6} exhibited higher photocatalytic activity for the photodecomposition of Rhodamine B (RhB) under the irradiation of Xe lamp and green light emitting diode (g-LED). The mechanism of the high photocatalytic activity was discussed by photoluminescence spectra (PL), which is mainly attributed to upconversion of NaYF{sub 4}:Er,Yb in the NaYF{sub 4}:Er,Yb/Bi{sub 2}MoO{sub 6} nanocomposite and the core–shell structure.« less

  9. Diclofenac degradation by heterogeneous photocatalysis with Fe3O4/Ti x O y /activated carbon fiber composite synthesized by ultrasound irradiation

    NASA Astrophysics Data System (ADS)

    Moreno-Valencia, E. I.; Paredes-Carrera, S. P.; Sánchez-Ochoa, J. C.; Flores-Valle, S. O.; Avendaño-Gómez, J. R.

    2017-11-01

    In this work, a photocatalytic system to degrade diclofenac was developed using a composite Fe3O4/Ti x O y on an activated carbon fiber. Diclofenac is widely used as an anti-inflammatory compound worldwide and it is constantly being added as waste in the environment (Heberer 2002 J. Hydrol. 266 175-89), exceeding the permissible maximum concentration in the wastewater (GEO-3 2002 Programa de las Naciones Unidas para el Medio Ambiente; Golet et al 2003 Environ. Sci. Technol. 37 3243-9 Oviedo et al 2010 Environ. Toxicol. Pharmacol. 29 9-43 Le-Minh et al 2010 Water Res. 44 4295-323 Legrini et al 1993 Chem. Rev. 1093 671-98). The composite was synthesized by sol-gel technique with and without ultrasound irradiation (Singh and Nakate 2014 J. Nanopart. 2014 326747). The solids were deposited by ultrasound irradiation on active carbon fiber in order to optimize the diclofenac degradation. The solids were characterized by x-ray diffraction (XRD), nitrogen physisorption (BET), and scanning electron microscopy with EDS microanalysis (SEM-EDS). The crystal size was calculated with the Debye-Scherrer equation, and the band gap values by the diffuse reflectance method. The evaluation process was studied by UV-vis spectroscopy (Rizzoa et al 2009 Water Res. 43 979-88). It was found that in this synthesis method (ultrasound), textural properties such as porosity, specific surface area and morphology depend on the ultrasound irradiation. The proposed system, Fe3O4/titanium oxide hydrate showed better degradation profile than TiO2 anatase phase; the increase of diclofenac degradation was attributed to the textural properties of the composite, it avoids the filtering process since the separation can be achieved by magnetizing and/or decantation.

  10. Environmental Baseline Survey Report for the Title Transfer of Land Parcel ED-4 at the East Tennessee Technology Park, Oak Ridge, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SAIC

    2008-05-01

    This environmental baseline survey (EBS) report documents the baseline environmental conditions of a land parcel referred to as 'ED-4' (ED-4) at the U. S. Department of Energy's (DOE's) East Tennessee Technology Park (ETTP). DOE is proposing to transfer the title of this land to the Heritage Center, LLC. Parcel ED-4 is a land parcel that consists of two noncontiguous areas comprising a total of approximately 18 acres located east of the ETTP. The western tract of ED-4 encompasses approximately 8.5 acres in the northeastern quadrant of the intersection of Boulevard Road and Highway 58. The eastern tract encompasses an areamore » of approximately 9.5 acres in the northwestern quadrant of the intersection of Blair Road and Highway 58 (the Oak Ridge Turnpike). Aerial photographs and site maps from throughout the history of the ETTP, going back to its initial development in the 1940s as the Oak Ridge Gaseous Diffusion Plant (ORGDP), indicate that this area has been undeveloped woodland with the exception of three support facilities for workers constructing the ORGDP since federal acquisition in 1943. These three support facilities, which were located in the western tract of ED-4, included a recreation hall, the Town Hall Camp Operations Building, and the Property Warehouse. A railroad spur also formerly occupied a portion of Parcel ED-4. These former facilities only occupied approximately 5 percent of the total area of Parcel ED-4. This report provides supporting information for the transfer of this government-owned property at ETTP to a non-federal entity. This EBS is based upon the requirements of Sect. 120(h) of the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). In order to support a Clean Parcel Determination (CPD) in accordance with CERCLA Sect. 120(h)(4)(d), groundwater and sediment samples were collected within, and adjacent to, the Parcel ED-4 study area. The potential for DOE to make a CPD for ED-4 is further supported by a No Further Investigation (NFI) determination made on land that adjoins ED-4 to the east (DOE 1997a) and to the south (DOE 1997b).« less

  11. Factors Influencing the Adoption of the Internet as a Teaching Tool at Foreign Language Schools

    ERIC Educational Resources Information Center

    Martins, Claudia B. M. J.; Steil, Andrea V.; Todesco, Jose L.

    2004-01-01

    The present article describes a research that determined the factors influencing language schools in Brazil to adopt the Internet as a teaching tool. The theoretical framework used was Rogers, E. (1995). "Diffusion of innovation" (4th ed.). New York: The Free Press. theory of perceived attributes. A survey was carried out with 92…

  12. Elastomeric Materials for Acoustical Applications

    DTIC Science & Technology

    1989-09-15

    pfa UAtuWt.1. for Ado.iuatal Applvaations 828, 28n. •uaring Outdo t ho014 )I"PonL 1notoHMora, 6 U, I, 1. o4ront. dJo fmourg A Oo., |mtbaomer hmiaogyD...34Permeation, Diffusion, and Sorption of Gases and Vapors," in Methods of Experimental Phycics, 10 R. A. Fava, ed. (Academic Press, New York, 1981

  13. Epithelial cancers and photon migration: Monte Carlo simulations and diffuse reflectance measurements

    NASA Astrophysics Data System (ADS)

    Tubiana, Jerome; Kass, Alex J.; Newman, Maya Y.; Levitz, David

    2015-07-01

    Detecting pre-cancer in epithelial tissues such as the cervix is a challenging task in low-resources settings. In an effort to achieve low cost cervical cancer screening and diagnostic method for use in low resource settings, mobile colposcopes that use a smartphone as their engine have been developed. Designing image analysis software suited for this task requires proper modeling of light propagation from the abnormalities inside tissues to the camera of the smartphones. Different simulation methods have been developed in the past, by solving light diffusion equations, or running Monte Carlo simulations. Several algorithms exist for the latter, including MCML and the recently developed MCX. For imaging purpose, the observable parameter of interest is the reflectance profile of a tissue under some specific pattern of illumination and optical setup. Extensions of the MCX algorithm to simulate this observable under these conditions were developed. These extensions were validated against MCML and diffusion theory for the simple case of contact measurements, and reflectance profiles under colposcopy imaging geometry were also simulated. To validate this model, the diffuse reflectance profiles of tissue phantoms were measured with a spectrometer under several illumination and optical settings for various homogeneous tissues phantoms. The measured reflectance profiles showed a non-trivial deviation across the spectrum. Measurements of an added absorber experiment on a series of phantoms showed that absorption of dye scales linearly when fit to both MCX and diffusion models. More work is needed to integrate a pupil into the experiment.

  14. Time-dependent diffuse reflectance spectroscopy for in vivo characterization of pediatric epileptogenic brain lesions

    NASA Astrophysics Data System (ADS)

    Oh, Sanghoon; Ragheb, John; Bhatia, Sanjiv; Sandberg, David; Johnson, Mahlon; Fernald, Bradley; Lin, Wei-Chiang

    2008-02-01

    Optical spectroscopy for in vivo tissue diagnosis is performed traditionally in a static manner; a snap shot of the tissue biochemical and morphological characteristics is captured through the interaction between light and the tissue. This approach does not capture the dynamic nature of a living organ, which is critical to the studies of brain disorders such as epilepsy. Therefore, a time-dependent diffuse reflectance spectroscopy system with a fiber-optic probe was designed and developed. The system was designed to acquire broadband diffuse reflectance spectra (240 ~ 932 nm) at an acquisition rate of 33 Hz. The broadband spectral acquisition feature allows simultaneous monitoring of various physiological characteristics of tissues. The utility of such a system in guiding pediatric epilepsy surgery was tested in a pilot clinical study including 13 epilepsy patients and seven brain tumor patients. The control patients were children undergoing suregery for brain tumors in which measurements were taken from normal brain exposed during the surgery. Diffuse reflectance spectra were acquired for 12 seconds from various parts of the brain of the patients during surgery. Recorded spectra were processed and analyzed in both spectral and time domains to gain insights into the dynamic changes in, for example, hemodynamics of the investigated brain tissue. One finding from this pilot study is that unsynchronized alterations in local blood oxygenation and local blood volume were observed in epileptogenic cortex. These study results suggest the advantage of using a time-dependent diffuse reflectance spectroscopy system to study epileptogenic brain in vivo.

  15. Clinical role of early dynamic FDG-PET/CT for the evaluation of renal cell carcinoma.

    PubMed

    Nakajima, Reiko; Abe, Koichiro; Kondo, Tsunenori; Tanabe, Kazunari; Sakai, Shuji

    2016-06-01

    We studied the usefulness of early dynamic (ED) and whole-body (WB) FDG-PET/CT for the evaluation of renal cell carcinoma (RCC). One hundred patients with 107 tumours underwent kidney ED and WB FDG-PET/CT. We visually and semiquantitatively evaluated the FDG accumulation in RCCs in the ED and WB phases, and compared the accumulation values with regard to histological type (clear cell carcinoma [CCC] vs. non-clear cell carcinoma [N-CCC]), the TNM stage (high stage [3-4] vs. low stage [1-2]), the Fuhrman grade (high grade [3-4] vs. low grade [1-2]) and presence versus absence of venous (V) and lymphatic (Ly) invasion. In the ED phase, visual evaluation revealed no significant differences in FDG accumulation in terms of each item. However, the maximum standardized uptake value and tumour-to-normal tissue ratios were significantly higher in the CCCs compared to the N-CCCs (p < 0.001). In the WB phase, in contrast, significantly higher FDG accumulation (p < 0.001) was found in RCCs with a higher TNM stage, higher Furman grade, and the presence of V and Ly invasion in both the visual and the semiquantitative evaluations. ED and WB FDG-PET/CT is a useful tool for the evaluation of RCCs. • ED and WB FDG-PET/ CT helps to assess patients with RCC • ED FDG-PET/CT enabled differentiation between CCC and N-CCC • FDG accumulation in the WB phase reflects tumour aggressiveness • Management of RCC is improved by ED and WB FDG-PET/CT.

  16. Low-acuity presentations to regional emergency departments: What is the issue?

    PubMed

    Cheek, Colleen; Allen, Penny; Shires, Lizzi; Parry, Denise; Ruigrok, Marielle

    2016-04-01

    To explore GP-referrals and self-referrals to EDs and factors associated with patients seeking low-acuity care at ED. Retrospective analysis of all ED presentations to Mersey Community Hospital and North West Regional Hospital (Tasmania) between 1 January 2009 and 31 December 2013. Cross-sectional survey of patients presenting to the EDs for care triaged as low-acuity. There were 255,365 ED presentations in the retrospective data: 11,252 (4.4%) GP-referrals and 218,205 (85.4%) self-referrals. At ED 49% of GP-referrals were triaged ATS 4 or 5 and 35% of self-referrals were triaged ATS 1-3. There were 138 (84.2%) low-acuity patients who completed the survey; predominantly, all attended for acute injury or illness. Single point-of-care convenience was most commonly selected (71%) as a reason for attending ED. Over 85% of patients who seek emergency care in this region self-refer, so understanding health-seeking behaviour is important. Most low-acuity patients are acutely injured or unwell, and the decision to go to ED is based on their perception of accessibility of expertise aligned with their need. The term 'GP-type' is misleading in this context and should not be used. Providing low-acuity care in parallel with providing a specialised emergency service meets the needs of the local community and is likely to be the lowest cost model in a regional and rural area. Funding models must reflect the actual cost of delivering this important service rather than presentation types. © 2015 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  17. Maternal history of eating disorders: Diet quality during pregnancy and infant feeding.

    PubMed

    Nguyen, Anh N; de Barse, Lisanne M; Tiemeier, Henning; Jaddoe, Vincent W V; Franco, Oscar H; Jansen, Pauline W; Voortman, Trudy

    2017-02-01

    We studied associations of maternal history of eating disorders (EDs) with diet quality of pregnant women and their infants, and breastfeeding practices. We included 6196 mother-child pairs from Generation R, a population-based cohort in the Netherlands. Maternal history of lifetime EDs was assessed during pregnancy with a questionnaire. Dietary intake during pregnancy and in infancy was assessed with food-frequency questionnaires and diet quality scores were calculated, reflecting adherence to dietary guidelines. Breastfeeding practices were assessed with questionnaires at 2, 6, and 12 months. We observed that, after adjustment for socioeconomic and lifestyle factors, women with a history of EDs had a higher diet quality than women without a history of EDs (B = 0.24 SD, 95%CI: 0.15; 0.33). Mothers with a history of EDs were less likely to breastfeed (unadjusted OR = 0.68, 95%CI: 0.51; 0.93), although no longer statistically significant after adjustment (OR = 0.75, 95%CI: 0.55; 1.03). These findings suggest that mothers with a history of EDs seem slightly less likely to initiate breastfeeding, however, this warrants further investigation. At the age of 1 year, infants of mothers with a history of EDs had a higher diet quality (B = 0.15 SD, 95%CI: 0.02; 0.27). We conclude that mothers with a history of EDs and their infants have a relative good diet quality, although follow-up studies are needed to assess long-term associations with diet in later childhood and adolescence. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Infrared deflectometry for the inspection of diffusely specular surfaces

    NASA Astrophysics Data System (ADS)

    Höfer, Sebastian; Burke, Jan; Heizmann, Michael

    2016-12-01

    Deflectometry is a full-field gradient technique that lends itself very well to testing specular surfaces. It uses the geometry of specular reflection to determine the gradient of the surface under inspection. In consequence, a necessary precondition to apply deflectometry is the presence of at least partially specular reflection. Surfaces with larger roughness have increasingly diffuse reflection characteristics, making them inaccessible to usual deflectometry. However, many industrially relevant surfaces exist that change their reflection characteristic during production and processing. An example is metal sheets that are used as car body parts. Whereas the molded but otherwise raw metal sheets show a mostly diffuse reflection without sufficient specular reflection, the final car body panels have a high specular reflectance due to the lacquering. In consequence, it would be advantageous to apply the same inspection approach both for the raw material and for the final product. To solve this challenge, specular reflection from rough surfaces can be achieved using light with a larger wavelength, as the specular reflectivity of a surface depends on the ratio of the surface roughness and the wavelength of the light applied. Wavelengths in the thermal infrared range create enough specular reflection to apply deflectometry on many visually rough metal surfaces. This contribution presents the principles of thermal deflectometry, its special challenges, and illustrates its use with examples from the inspection of industrially produced surfaces.

  19. Performance Comparison of Systematic Methods for Rigorous Definition of Coarse-Grained Sites of Large Biomolecules.

    PubMed

    Zhang, Yuwei; Cao, Zexing; Zhang, John Zenghui; Xia, Fei

    2017-02-27

    Construction of coarse-grained (CG) models for large biomolecules used for multiscale simulations demands a rigorous definition of CG sites for them. Several coarse-graining methods such as the simulated annealing and steepest descent (SASD) based on the essential dynamics coarse-graining (ED-CG) or the stepwise local iterative optimization (SLIO) based on the fluctuation maximization coarse-graining (FM-CG), were developed to do it. However, the practical applications of these methods such as SASD based on ED-CG are subject to limitations because they are too expensive. In this work, we extend the applicability of ED-CG by combining it with the SLIO algorithm. A comprehensive comparison of optimized results and accuracy of various algorithms based on ED-CG show that SLIO is the fastest as well as the most accurate algorithm among them. ED-CG combined with SLIO could give converged results as the number of CG sites increases, which demonstrates that it is another efficient method for coarse-graining large biomolecules. The construction of CG sites for Ras protein by using MD fluctuations demonstrates that the CG sites derived from FM-CG can reflect the fluctuation properties of secondary structures in Ras accurately.

  20. Physiological basis for noninvasive skin cancer diagnosis using diffuse reflectance spectroscopy

    NASA Astrophysics Data System (ADS)

    Zhang, Yao; Markey, Mia K.; Tunnell, James W.

    2017-02-01

    Diffuse reflectance spectroscopy offers a noninvasive, fast, and low-cost alternative to visual screening and biopsy for skin cancer diagnosis. We have previously acquired reflectance spectra from 137 lesions in 76 patients and determined the capability of spectral diagnosis using principal component analysis (PCA). However, it is not well elucidated why spectral analysis enables tissue classification. To provide the physiological basis, we used the Monte Carlo look-up table (MCLUT) model to extract physiological parameters from those clinical data. The MCLUT model results in the following physiological parameters: oxygen saturation, hemoglobin concentration, melanin concentration, vessel radius, and scattering parameters. Physiological parameters show that cancerous skin tissue has lower scattering and larger vessel radii, compared to normal tissue. These results demonstrate the potential of diffuse reflectance spectroscopy for detection of early precancerous changes in tissue. In the future, a diagnostic algorithm that combines these physiological parameters could be enable non-invasive diagnosis of skin cancer.

  1. Reflectance spectroscopy for noninvasive evaluation of hair follicle stage

    NASA Astrophysics Data System (ADS)

    Liu, Caihua; Guan, Yue; Wang, Jianru; Zhong, Xiewei; Liu, Xiuli; Zhu, Dan

    2015-05-01

    Hair follicle offers an excellent model for systems biology and regenerative medicine. So far, the stages of hair follicle growth have been evaluated by histological examination. In this work, a noninvasive spectroscopy was proposed by measuring the diffuse reflectance of mouse skin and analyzing the melanin value. Results show that the skin diffuse reflectance was relatively high when hair follicles were at the telogen stage and at the beginning of the anagen stage, and decreased with the progression of the anagen stage. When the hair follicle entered into the catagen stage, the diffuse reflectance gradually increased. The changes in the melanin content of skin had contrary dynamics. Substages of the hair follicle cycle could be distinguished by comparing the changes in melanin value with the histological examination. This study provided a new method for noninvasive evaluation of the hair follicle stage, and should be valuable for basic and therapeutic investigations on hair regeneration.

  2. What Makes Community Engagement Effective?: Lessons from the Eliminate Dengue Program in Queensland Australia

    PubMed Central

    2015-01-01

    Background Worldwide, more than 40% of the population is at risk from dengue and recent estimates suggest that up to 390 million dengue infections are acquired every year. The Eliminate Dengue (ED) Program is investigating the use of Wolbachia-infected, transmission-compromised, mosquitoes to reduce dengue transmission. Previous introductions of genetically-modified strategies for dengue vector control have generated controversy internationally by inadequately engaging host communities. Community Engagement (CE) was a key component of the ED Program’s initial open release trials in Queensland Australia. Their approach to CE was perceived as effective by the ED team’s senior leadership, members of its CE team, and by its funders, but if and why this was the case was unclear. We conducted a qualitative case study of the ED Program’s approach to CE to identify and critically examine its components, and to explain whether and how these efforts contributed to the support received by stakeholders. Methodology/Principal Findings In-depth semi-structured interviews were conducted with 24 participants with a range of experiences and perspectives related to the ED Program’s CE activities. Our analytic approach combined techniques of grounded theory and qualitative description. The ED Program’s approach to CE reflected four foundational features: 1) enabling conditions; 2) leadership; 3) core commitments and guiding values; and 4) formative social science research. These foundations informed five key operational practices: 1) building the CE team; 2) integrating CE into management practices; 3) discerning the community of stakeholders; 4) establishing and maintaining a presence in the community; and 5) socializing the technology and research strategy. We also demonstrate how these practices contributed to stakeholders’ willingness to support the trials. Conclusions/Significance Our case study has identified, and explained the functional relationships among, the critical features of the ED Program’s approach to CE. It has also illuminated how these features were meaningful to stakeholders and contributed to garnering support within the host communities for the open-release trials. Our findings reveal how translating ethical intentions into effective action is more socially complex than is currently reflected in the CE literature. Because our case study delineates the critical features of the ED Program’s approach to CE, it can serve as a framework for other programs to follow when designing their own strategies. And because the findings outline a theory of change for CE, it can also serve as a starting point for developing an evaluation framework for CE. PMID:25875485

  3. Interprofessional communication supporting clinical handover in emergency departments: An observation study.

    PubMed

    Redley, Bernice; Botti, Mari; Wood, Beverley; Bucknall, Tracey

    2017-08-01

    Poor interprofessional communication poses a risk to patient safety at change-of-shift in emergency departments (EDs). The purpose of this study was to identify and describe patterns and processes of interprofessional communication impacting quality of ED change-of-shift handovers. Observation of 66 change-of-shift handovers at two acute hospital EDs in Victoria, Australia. Focus groups with 34 nurse participants complemented the observations. Qualitative data analysis involved content and thematic methods. Four structural components of ED handover processes emerged represented by (ABCD): (1) Antecedents; (2) Behaviours and interactions; (3) Content; and (4) Delegation of ongoing care. Infrequent and ad hoc interprofessional communication and discipline-specific handover content and processes emerged as specific risks to patient safety at change-of-shift handovers. Three themes related to risky and effective practices to support interprofessional communications across the four stages of ED handovers emerged: 1) standard processes and practices, 2) teamwork and interactions and 3) communication activities and practices. Unreliable interprofessional communication can impact the quality of change-of-shift handovers in EDs and poses risk to patient safety. Structured reflective analysis of existing practices can identify opportunities for standardisation, enhanced team practices and effective communication across four stages of the handover process to support clinicians to enhance local handover practices. Future research should test and refine models to support analysis of practice, and identify and test strategies to enhance ED interprofessional communication to support clinical handovers. Copyright © 2017 College of Emergency Nursing Australasia. Published by Elsevier Ltd. All rights reserved.

  4. Sound propagation in street canyons: comparison between diffusely and geometrically reflecting boundaries

    PubMed

    Kang

    2000-03-01

    This paper systematically compares the sound fields in street canyons with diffusely and geometrically reflecting boundaries. For diffuse boundaries, a radiosity-based theoretical/computer model has been developed. For geometrical boundaries, the image source method has been used. Computations using the models show that there are considerable differences between the sound fields resulting from the two kinds of boundaries. By replacing diffuse boundaries with geometrical boundaries, the sound attenuation along the length becomes significantly less; the RT30 is considerably longer; and the extra attenuation caused by air or vegetation absorption is reduced. There are also some similarities between the sound fields under the two boundary conditions. For example, in both cases the sound attenuation along the length with a given amount of absorption is the highest if the absorbers are arranged on one boundary and the lowest if they are evenly distributed on all boundaries. Overall, the results suggest that, from the viewpoint of urban noise reduction, it is better to design the street boundaries as diffusely reflective rather than acoustically smooth.

  5. Relationships between diffuse reflectance and vegetation canopy variables based on the radiative transfer theory

    NASA Technical Reports Server (NTRS)

    Park, J. K.; Deering, D. W.

    1981-01-01

    Out of the lengthy original expression of the diffuse reflectance formula, simple working equations were derived by employing characteristic parameters, which are independent of the canopy coverage and identifiable by field observations. The typical asymptotic nature of reflectance data that is usually observed in biomass studies was clearly explained. The usefulness of the simplified equations was demonstrated by the exceptionally close fit of the theoretical curves to two separately acquired data sets for alfalfa and shortgrass prairie canopies.

  6. Diffusely Reflecting Paints Containing TFE

    NASA Technical Reports Server (NTRS)

    Shai, M. C.; Schutt, J. B.

    1985-01-01

    Highly reflective, diffused coatings developed by incorporating polytetrafluoroethylene (TFE) pigment with alcohol-soluble binders. Alcohol and binder mixed together in blender before adding TFE. TFE preferably outgassed in mechanical-pump vacuum for typical interval of 4 hours before adding to liquid. Like wetting agent, vacuum treatment helps to prevent clumping of TFE and eases dispersion throughout mixture. Mixture blended for 3 to 5 minutes before used. Coatings useful on reflectance-standard surfaces for calibrating radiometric instruments in both laboratory and field. Paints washable and usable as optical reference surfaces.

  7. Noninvasive diagnostics of skin microphysical parameters based on spatially resolved diffuse reflectance spectroscopy

    NASA Astrophysics Data System (ADS)

    Lisenko, S. A.; Kugeiko, M. M.

    2013-01-01

    The ability to determine noninvasively microphysical parameters (MPPs) of skin characteristic of malignant melanoma was demonstrated. The MPPs were the melanin content in dermis, saturation of tissue with blood vessels, and concentration and effective size of tissue scatterers. The proposed method was based on spatially resolved spectral measurements of skin diffuse reflectance and multiple regressions between linearly independent measurement components and skin MPPs. The regressions were established by modeling radiation transfer in skin with a wide variation of its MPPs. Errors in the determination of skin MPPs were estimated using fiber-optic measurements of its diffuse reflectance at wavelengths of commercially available semiconductor diode lasers (578, 625, 660, 760, and 806 nm) at source-detector separations of 0.23-1.38 mm.

  8. Determination of optical band gap of powder-form nanomaterials with improved accuracy

    NASA Astrophysics Data System (ADS)

    Ahsan, Ragib; Khan, Md. Ziaur Rahman; Basith, Mohammed Abdul

    2017-10-01

    Accurate determination of a material's optical band gap lies in the precise measurement of its absorption coefficients, either from its absorbance via the Beer-Lambert law or diffuse reflectance spectrum via the Kubelka-Munk function. Absorption coefficients of powder-form nanomaterials calculated from absorbance spectrum do not match those calculated from diffuse reflectance spectrum, implying the inaccuracy of the traditional optical band gap measurement method for such samples. We have modified the Beer-Lambert law and the Kubelka-Munk function with proper approximations for powder-form nanomaterials. Applying the modified method for powder-form nanomaterial samples, both absorbance and diffuse reflectance spectra yield exactly the same absorption coefficients and therefore accurately determine the optical band gap.

  9. Landsat test of diffuse reflectance models for aquatic suspended solids measurement

    NASA Technical Reports Server (NTRS)

    Munday, J. C., Jr.; Alfoldi, T. T.

    1979-01-01

    Landsat radiance data were used to test mathematical models relating diffuse reflectance to aquatic suspended solids concentration. Digital CCT data for Landsat passes over the Bay of Fundy, Nova Scotia were analyzed on a General Electric Co. Image 100 multispectral analysis system. Three data sets were studied separately and together in all combinations with and without solar angle correction. Statistical analysis and chromaticity analysis show that a nonlinear relationship between Landsat radiance and suspended solids concentration is better at curve-fitting than a linear relationship. In particular, the quasi-single-scattering diffuse reflectance model developed by Gordon and coworkers is corroborated. The Gordon model applied to 33 points of MSS 5 data combined from three dates produced r = 0.98.

  10. Cortexin diffusion in human eye sclera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Genina, Elina A; Bashkatov, A N; Tuchin, Valerii V

    2011-05-31

    Investigation of the diffusion of cytamines, a typical representative of which is cortexin, is important for evaluating the drug dose, necessary to provide sufficient concentration of the preparation in the inner tissues of the eye. In the present paper, the cortexin diffusion rate in the eye sclera is measured using the methods of optical coherence tomography (OCT) and reflectance spectroscopy. The technique for determining the diffusion coefficient is based on the registration of temporal dependence of the eye sclera scattering parameters caused by partial replacement of interstitial fluid with the aqueous cortexin solution, which reduces the level of the OCTmore » signal and decreases the reflectance of the sclera. The values of the cortexin diffusion coefficient obtained using two independent optical methods are in good agreement. (optical technologies in biophysics and medicine)« less

  11. Diagnosing erectile dysfunction: the penile dynamic colour duplex ultrasound revisited.

    PubMed

    Aversa, A; Bruzziches, R; Spera, G

    2005-12-01

    A number of disease processes of the penis including Peyronie's disease, priapism, penile fractures and tumors are clearly visualized with ultrasound. Diagnostic evaluation of erectile dysfunction (ED) by penile dynamic colour-duplex Doppler ultrasonography (D-CDDU) is actually considered a second level approach to ED patients because of the fact that intracavernous injections test IV with prostaglandin-E(1) may provide important information about the patients' erectile capacity. However, no direct vascular imaging and a high percentage of false negative diagnoses of vasculogenic ED are its major pitfalls and subsequent treatment decisions remain quite limited. The occurrence of ED and its sentinel relationship to cardiovascular disease has prompted more accurate vascular screening in all patients even in the absence of cardiovascular risk factors. The sonographic evaluation of the intima-media thickness of the carotid arteries may sometimes represent an early manifestation of diffuse atherosclerotic disease and endothelial damage. This latter finding is often the cause of failure to oral agents, i.e. phosphodiesterase inhibitors, because of inability of the dysfunctional endothelium to release nitric oxide. D-CDDU represents an accurate tool to investigate cavernous artery inflow and venous leakage when compared with more invasive diagnostic techniques i.e. selective arteriography and dynamic infusion cavernosometry along with cavernosography.

  12. Implementation of cost-effective diffuse light source mechanism to reduce specular reflection and halo effects for resistor-image processing

    NASA Astrophysics Data System (ADS)

    Chen, Yung-Sheng; Wang, Jeng-Yau

    2015-09-01

    Light source plays a significant role to acquire a qualified image from objects for facilitating the image processing and pattern recognition. For objects possessing specular surface, the phenomena of reflection and halo appearing in the acquired image will increase the difficulty of information processing. Such a situation may be improved by the assistance of valuable diffuse light source. Consider reading resistor via computer vision, due to the resistor's specular reflective surface it will face with a severe non-uniform luminous intensity on image yielding a higher error rate in recognition without a well-controlled light source. A measurement system including mainly a digital microscope embedded in a replaceable diffuse cover, a ring-type LED embedded onto a small pad carrying a resistor for evaluation, and Arduino microcontrollers connected with PC, is presented in this paper. Several replaceable cost-effective diffuse covers made by paper bowl, cup and box inside pasted with white paper are presented for reducing specular reflection and halo effects and compared with a commercial diffuse some. The ring-type LED can be flexibly configured to be a full or partial lighting based on the application. For each self-made diffuse cover, a set of resistors with 4 or 5 color bands are captured via digital microscope for experiments. The signal-to-noise ratio from the segmented resistor-image is used for performance evaluation. The detected principal axis of resistor body is used for the partial LED configuration to further improve the lighting condition. Experimental results confirm that the proposed mechanism can not only evaluate the cost-effective diffuse light source but also be extended as an automatic recognition system for resistor reading.

  13. Diffuse interstellar bands in reflection nebulae

    NASA Technical Reports Server (NTRS)

    Fischer, O.; Henning, Thomas; Pfau, Werner; Stognienko, R.

    1994-01-01

    A Monte Carlo code for radiation transport calculations is used to compare the profiles of the lambda lambda 5780 and 6613 Angstrom diffuse interstellar bands in the transmitted and the reflected light of a star embedded within an optically thin dust cloud. In addition, the behavior of polarization across the bands were calculated. The wavelength dependent complex indices of refraction across the bands were derived from the embedded cavity model. In view of the existence of different families of diffuse interstellar bands the question of other parameters of influence is addressed in short.

  14. MODIS Solar Diffuser Attenuation Screen Modeling Results

    NASA Technical Reports Server (NTRS)

    Waluschka, Eugene; Xuong, Xiaoxiong; Guenther, Bruce; Barnes, William

    2004-01-01

    On-orbit calibration of the reflected solar bands on the EOS Moderate Resolution Imaging Spectroradiometer (MODIS) is accomplished by have the instrument view a high reflectance diffuse surface illuminated by the sun. For some of the spectral bands this proves to be much too bright a signal that results in the saturation of detectors designed for measuring low reflectance (ocean) surfaces signals. A mechanical attenuation device in the form of a pin hole screen is used to reduce the signals to calibrate these bands. The sensor response to solar illumination of the SD with and without the attenuation screen in place will be presented. The MODIS detector response to the solar diffuser is smooth when the attenuation screen is absent, but has structures up to a few percent when the attenuation screen is present. This structure corresponds to non-uniform illumination from the solar diffuser. Each pin hole produces a pin-hole image of the sun on the solar diffuser, and there are very many pin hole images of the sun on the solar diffuser for each MODIS detector. Even though there are very many pin-hole images of the sun on the solar diffuser, it is no longer perfectly uniformly illuminated. This non-uniformly illuminated solar diffuser produces intensity variation on the focal planes. The results of a very detailed simulation will be discussed which show how the illumination of the focal plane changes as a result of the attenuation, and the impacts on the calibration will be discussed.

  15. Insurance Expansion and Hospital Emergency Department Access: Evidence From the Affordable Care Act.

    PubMed

    Garthwaite, Craig; Gross, Tal; Notowidigdo, Matthew; Graves, John A

    2017-02-07

    Little is known about whether insurance expansion affects the location and type of emergency department (ED) use. Understanding these changes can inform state-level decisions about the Medicaid expansion under the Patient Protection and Affordable Care Act (ACA). To investigate the effect of the 2014 ACA Medicaid expansion on the location, insurance status, and type of ED visits. Quasi-experimental observational study from 2012 to 2014. 126 investor-owned, hospital-based EDs. Uninsured and Medicaid-insured adults aged 18 to 64 years. ACA expansion of Medicaid in January 2014. Number of ED visits overall, type of visit (for example, nondiscretionary or nonemergency), and average travel time to the ED. Interrupted time-series analyses comparing changes from the end of 2013 to end of 2014 for patients from Medicaid expansion versus nonexpansion states were done. There were 1.06 million ED visits among patients from 17 Medicaid expansion states, and 7.87 million ED visits among patients from 19 nonexpansion states. The EDs treating patients from Medicaid expansion states saw an overall 47.1% decrease in uninsured visits (95% CI, -65.0% to -29.3%) and a 125.7% (CI, 89.2% to 162.6%) increase in Medicaid visits after 12 months of ACA expansion. Average travel time for nondiscretionary conditions requiring immediate medical care decreased by 0.9 minutes (-6.2% [CI, -8.9% to -3.5%]) among all Medicaid patients from expansion states. We found little evidence of similar changes among patients from nonexpansion states. Results reflect shifts in ED care at investor-owned facilities, which limits generalizability to other hospital types. Meaningful changes in insurance status and location and type of ED visits in the first year of ACA Medicaid expansion were found, suggesting that expansion provides patients with a greater choice of hospital facilities. Robert Wood Johnson Foundation.

  16. Bidirectional reflectance distribution function effects in ladar-based reflection tomography.

    PubMed

    Jin, Xuemin; Levine, Robert Y

    2009-07-20

    Light reflection from a surface is described by the bidirectional reflectance distribution function (BRDF). In this paper, BRDF effects in reflection tomography are studied using modeled range-resolved reflection from well-characterized geometrical surfaces. It is demonstrated that BRDF effects can cause a darkening at the interior boundary of the reconstructed surface analogous to the well-known beam hardening artifact in x-ray transmission computed tomography (CT). This artifact arises from reduced reflection at glancing incidence angles to the surface. It is shown that a purely Lambertian surface without shadowed components is perfectly reconstructed from range-resolved measurements. This result is relevant to newly fabricated carbon nanotube materials. Shadowing is shown to cause crossed streak artifacts similar to limited-angle effects in CT reconstruction. In tomographic reconstruction, these effects can overwhelm highly diffuse components in proximity to specularly reflecting elements. Diffuse components can be recovered by specialized processing, such as reducing glints via thresholded measurements.

  17. Numerical Modelling of the Sound Fields in Urban Streets with Diffusely Reflecting Boundaries

    NASA Astrophysics Data System (ADS)

    KANG, J.

    2002-12-01

    A radiosity-based theoretical/computer model has been developed to study the fundamental characteristics of the sound fields in urban streets resulting from diffusely reflecting boundaries, and to investigate the effectiveness of architectural changes and urban design options on noise reduction. Comparison between the theoretical prediction and the measurement in a scale model of an urban street shows very good agreement. Computations using the model in hypothetical rectangular streets demonstrate that though the boundaries are diffusely reflective, the sound attenuation along the length is significant, typically at 20-30 dB/100 m. The sound distribution in a cross-section is generally even unless the cross-section is very close to the source. In terms of the effectiveness of architectural changes and urban design options, it has been shown that over 2-4 dB extra attenuation can be obtained either by increasing boundary absorption evenly or by adding absorbent patches on the façades or the ground. Reducing building height has a similar effect. A gap between buildings can provide about 2-3 dB extra sound attenuation, especially in the vicinity of the gap. The effectiveness of air absorption on increasing sound attenuation along the length could be 3-9 dB at high frequencies. If a treatment is effective with a single source, it is also effective with multiple sources. In addition, it has been demonstrated that if the façades in a street are diffusely reflective, the sound field of the street does not change significantly whether the ground is diffusely or geometrically reflective.

  18. MODIS Solar Diffuser On-orbit Performance

    NASA Technical Reports Server (NTRS)

    Xiong, Xiaoxiong; Chen, H.; Choi, T.; Sun, J.; Angal, A.

    2008-01-01

    MODIS is a key instrument for the NASA Earth Observing System (EOS), currently operated on both the Terra and Aqua missions. Each MODIS instrument has 20 reflective solar bands (RSBs) and 16 thermal emissive bands (TEBs). MODIS RSB on-orbit calibration is reflectance based using an on-board solar diffuser (SD). The SD bi-directional reflectance factors (BRFs) were characterized pre-launch using reference diffuser samples, which are traceable to NIST reflectance standards. The SD BRF on-orbit degradation (or change) is tracked by another onboard device, called the solar diffuser stability monitor (SDSM). The SDSM is operated during each scheduled SD calibration event, making alternate observations of direct sunlight and the diffusely reflected sunlight from the SD. The time series of the ratios of SDSM's SD view to its Sun view provide SD degradation information. This paper presents and compares the Terra and Aqua MODIS SD on-orbit performance. Results show that the SD on-orbit degradation depends on the amount of solar exposure of the SD plate. In addition, it is strongly wavelengthdependent, with a larger degradation rate at shorter wavelengths. For Terra MODIS, an SD door anomaly occurred in May 2003 that led to a decision to fix the door permanently at an "open" position. Since then, the SD degradation rate has significantly increased due to more frequent solar exposure. As expected, the SD on-orbit performance directly impacts the RSB calibration performance. The lessons learned from MODIS on-orbit calibration will provide useful insights into the development and operation of future SD calibration systems.

  19. Surface modification of an amorphous Si thin film crystallized by a linearly polarized Nd:YAG pulse laser beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Horita, Susumu; Kaki, Hirokazu; Nishioka, Kensuke

    2007-07-01

    Amorphous Si films of 60 and 10 nm thick on glass substrates were irradiated by a linearly polarized Nd:YAG pulse laser with the wavelength {lambda}=532 nm at the incident angle {theta}{sub i}=0. The surface of the irradiated 60-nm-thick film had both periodic ridges perpendicular to the electric field vector E and aperiodic ridges roughly parallel to E, where the spatial period of the periodic ridges was almost {lambda}. From the continuous 10-nm-thick film, the separate rectangular Si islands were formed with a periodic distance of {lambda}, with the edges parallel or perpendicular to E. When {theta}{sub i} was increased frommore » normal incidence of the s-polarized beam for a 60-nm-thick film, the aperiodic ridges were reduced while the periodic ridges were still formed. For a 10-nm-thick film, the Si stripes were formed perpendicular to E, using the s-polarized beam at {theta}{sub i}=12 deg. In order to investigate the mechanisms of the surface modifications of, in particular, aperiodic ridges, islands, and stripes, we improved the previous theoretical model of the periodic distribution of the beam energy density (periodic E-D) generated by irradiation of the linearly polarized laser beam, taking account of the multireflection effect in the Si film which is semitransparent for {lambda}. Further, the calculated E-D was corrected with respect to the thermal diffusion in the irradiated Si film. The calculation results show that the two-dimensional E-D consists of a constant or a dc term and a sinusoidal or an ac term which contains various spatial periods. The multireflection effect strongly influences the amplitude and phase of every ac term, which means that the amplitude and phase depend on the film thickness. The thermal diffusion during the heating of the irradiated film greatly reduces the amplitudes of the ac terms with periods below the thermal diffusion length. The theoretical calculation showed that, by increasing {theta}{sub i}, the temperature distribution in the irradiated Si film was changed from two-dimensional toward one-dimensional, which can explain the above experimental results reasonably.« less

  20. Accelerated rescaling of single Monte Carlo simulation runs with the Graphics Processing Unit (GPU).

    PubMed

    Yang, Owen; Choi, Bernard

    2013-01-01

    To interpret fiber-based and camera-based measurements of remitted light from biological tissues, researchers typically use analytical models, such as the diffusion approximation to light transport theory, or stochastic models, such as Monte Carlo modeling. To achieve rapid (ideally real-time) measurement of tissue optical properties, especially in clinical situations, there is a critical need to accelerate Monte Carlo simulation runs. In this manuscript, we report on our approach using the Graphics Processing Unit (GPU) to accelerate rescaling of single Monte Carlo runs to calculate rapidly diffuse reflectance values for different sets of tissue optical properties. We selected MATLAB to enable non-specialists in C and CUDA-based programming to use the generated open-source code. We developed a software package with four abstraction layers. To calculate a set of diffuse reflectance values from a simulated tissue with homogeneous optical properties, our rescaling GPU-based approach achieves a reduction in computation time of several orders of magnitude as compared to other GPU-based approaches. Specifically, our GPU-based approach generated a diffuse reflectance value in 0.08ms. The transfer time from CPU to GPU memory currently is a limiting factor with GPU-based calculations. However, for calculation of multiple diffuse reflectance values, our GPU-based approach still can lead to processing that is ~3400 times faster than other GPU-based approaches.

  1. Reflectance spectroscopy can quantify cutaneous haemoglobin oxygenation by oxygen uptake from the atmosphere after epidermal barrier disruption.

    PubMed

    Heise, H M; Lampen, P; Stücker, M

    2003-11-01

    The supply of oxygen to the viable skin tissue within the upper layers is not only secured by the cutaneous blood vascular system, but to a significant part also by oxygen diffusion from the atmosphere through the horny layer. The aim of this study was to examine whether changes in haemoglobin oxygenation can be observed within the isolated perfused bovine udder skin used as a skin model by removing the upper horny layer by adhesive tape stripping. Diffuse reflectance spectroscopy in the visible spectral range was used for non-invasive characterisation of haemoglobin oxygenation in skin under in vitro conditions. Mid-infrared attenuated total reflectance spectroscopy was employed for analysing the surface layer of the stratum corneum with respect to keratin, water and lipid components. Skin barrier disruption was achieved by repeated stripping of superficial corneocyte layers by adhesive tape. Significant changes in skin haemoglobin oxygenation were observed for skin areas with reduced lipid concentration and a reduced stratum corneum layer, as determined from the quantitative evaluation of the diffuse reflectance skin spectra. The result can be interpreted as an increase of oxygen diffusion after the removal of the upper horny layer.

  2. Technique for examining biological materials using diffuse reflectance spectroscopy and the kubelka-munk function

    DOEpatents

    Alfano, Robert R.; Yang, Yuanlong

    2003-09-02

    Method and apparatus for examining biological materials using diffuse reflectance spectroscopy and the Kubelka-Munk function. In one aspect, the method is used to determine whether a tissue sample is cancerous or not and comprises the steps of (a) measuring the diffuse reflectance from the tissue sample at a first wavelength and at a second wavelength, wherein the first wavelength is a wavelength selected from the group consisting of 255-265 nm and wherein the second wavelength is a wavelength selected from the group consisting of 275-285 nm; (b) using the Kubelka-Munk function to transform the diffuse reflectance measurement obtained at the first and second wavelengths; and (c) comparing a ratio or a difference of the transformed Kubelka-Munk measurements at the first and second wavelengths to appropriate standards determine whether or not the tissue sample is cancerous. One can use the spectral profile of KMF between 250 nm to 300 nm to determine whether or not the tissue sample is cancerous or precancerous. According to the value at the first and second wavelengths determine whether or not the malignant tissue is invasive or mixed invasive and in situ or carcinoma in situ.

  3. Role of Multiple Atmospheric Reflections in Formation of Electron Distribution Function in the Diffuse Aurora Region. Chapter 9

    NASA Technical Reports Server (NTRS)

    Khazanov, George V.; Himwich, Elizabeth W.; Glocer, Alex; Sibeck, David G.

    2015-01-01

    The precipitation of high-energy magnetospheric electrons (E greater than 500-600 electronvolts) in the diffuse aurora contributes significant energy flux into Earth's ionosphere. In the diffuse aurora, precipitating electrons initially injected from the plasmasheet via wave-particle interaction processes degrade in the atmosphere toward lower energies and produce secondary electrons via impact ionization of the neutral atmosphere. These initially precipitating electrons of magnetospheric origin can be additionally reflected back into the magnetosphere by the two magnetically conjugated atmospheres, leading to a series of multiple reflections that can greatly influence the initially precipitating flux at the upper ionospheric boundary (700-800 kilometers) and the resultant population of secondary electrons and electrons cascading toward lower energies. We present the solution of the Boltzmann.Landau kinetic equation that uniformly describes the entire electron distribution function in the diffuse aurora, including the affiliated production of secondary electrons (E is less than or equal to 600 electronvolts) and their energy interplay in the magnetosphere and two conjugated ionospheres. This solution takes into account the role of multiple atmospheric reflections of the precipitated electrons that were initially moved into the loss cone via wave.particle interaction processes in Earth's plasmasheet.

  4. Spatially resolved, diffuse reflectance imaging for subsurface pattern visualization toward development of a lensless imaging platform: phantom experiments

    NASA Astrophysics Data System (ADS)

    Schelkanova, Irina; Pandya, Aditya; Saiko, Guennadi; Nacy, Lidia; Babar, Hannan; Shah, Duoaud; Lilge, Lothar; Douplik, Alexandre

    2016-01-01

    A portable, spatially resolved, diffuse reflectance lensless imaging technique based on the charge-coupled device or complementary metal-oxide semiconductor sensor directly coupled to the fiber optic bundle is proposed for visualization of subsurface structures such as superficial microvasculature in the epithelium. We discuss an experimental method for emulating a lensless imaging setup via raster scanning a single fiber-optic cable over a microfluidic phantom containing periodic hemoglobin absorption contrast. To evaluate the ability of the technique to recover information about the subsurface linear structures, scattering layers formed of the Sylgard® 184 Silicone Elastomer and titanium dioxide were placed atop the microfluidic phantom. Thickness of the layers ranged from 0.2 to 0.7 mm, and the values of the reduced scattering coefficient (μs‧) were between 0.85 and 4.25 mm-1. The results demonstrate that fiber-optic, lensless platform can be used for two-dimensional imaging of absorbing inclusions in diffuse reflectance mode. In these experiments, it was shown that diffuse reflectance imaging can provide sufficient spatial sampling of the phantom for differentiation of 30 μm structural features of the embedded absorbing pattern inside the scattering media.

  5. ANALYTICAL SOLUTIONS OF THE ATMOSPHERIC DIFFUSION EQUATION WITH MULTIPLE SOURCES AND HEIGHT-DEPENDENT WIND SPEED AND EDDY DIFFUSIVITIES. (R825689C072)

    EPA Science Inventory

    Abstract

    Three-dimensional analytical solutions of the atmospheric diffusion equation with multiple sources and height-dependent wind speed and eddy diffusivities are derived in a systematic fashion. For homogeneous Neumann (total reflection), Dirichlet (total adsorpti...

  6. ANALYTICAL SOLUTIONS OF THE ATMOSPHERIC DIFFUSION EQUATION WITH MULTIPLE SOURCES AND HEIGHT-DEPENDENT WIND SPEED AND EDDY DIFFUSIVITIES. (R825689C048)

    EPA Science Inventory

    Abstract

    Three-dimensional analytical solutions of the atmospheric diffusion equation with multiple sources and height-dependent wind speed and eddy diffusivities are derived in a systematic fashion. For homogeneous Neumann (total reflection), Dirichlet (total adsorpti...

  7. The Emergency Department Safety Assessment and Follow-up Evaluation (ED-SAFE): method and design considerations.

    PubMed

    Boudreaux, Edwin D; Miller, Ivan; Goldstein, Amy B; Sullivan, Ashley F; Allen, Michael H; Manton, Anne P; Arias, Sarah A; Camargo, Carlos A

    2013-09-01

    Due to the concentration of individuals at-risk for suicide, an emergency department visit represents an opportune time for suicide risk screening and intervention. The Emergency Department Safety Assessment and Follow-up Evaluation (ED-SAFE) uses a quasi-experimental, interrupted time series design to evaluate whether (1) a practical approach to universally screening ED patients for suicide risk leads to improved detection of suicide risk and (2) a multi-component intervention delivered during and after the ED visit improves suicide-related outcomes. This paper summarizes the ED-SAFE's study design and methods within the context of considerations relevant to effectiveness research in suicide prevention and pertinent human participants concerns. 1440 suicidal individuals, from 8 general ED's nationally will be enrolled during three sequential phases of data collection (480 individuals/phase): (1) Treatment as Usual; (2) Universal Screening; and (3) Intervention. Data from the three phases will inform two separate evaluations: Screening Outcome (Phases 1 and 2) and Intervention (Phases 2 and 3). Individuals will be followed for 12 months. The primary study outcome is a composite reflecting completed suicide, attempted suicide, aborted or interrupted attempts, and implementation of rescue procedures during an outcome assessment. While 'classic' randomized control trials (RCT) are typically selected over quasi-experimental designs, ethical and methodological issues may make an RCT a poor fit for complex interventions in an applied setting, such as the ED. ED-SAFE represents an innovative approach to examining the complex public health issue of suicide prevention through a multi-phase, quasi-experimental design embedded in 'real world' clinical settings. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Clinical care of persons with dementia in the emergency department: a review of the literature and agenda for research.

    PubMed

    Clevenger, Carolyn K; Chu, Thasha A; Yang, Zhou; Hepburn, Kenneth W

    2012-09-01

    The segment of older adults who present to the emergency department (ED) with cognitive impairment ranges from 21% to 40%. Difficulties inherent in the chaotic ED setting combined with dementia may result in a number of unwanted clinical outcomes, but strategies to minimize these outcomes are lacking. A review of the literature was conducted to examine the practices undertaken in the care of persons with dementia (PWD) specific to the ED setting. PubMed and Cumulative Index to Nursing and Allied Health Literature were searched for published articles specific to the care of PWD provided in the ED. All English-language articles were reviewed; editorials and reflective journals were excluded. Seven articles ultimately met inclusion criteria; all provided Level 7 evidence: narrative review or opinions from authorities. The articles recommended clinical practices that can be categorized into five themes: assessment of cognitive impairment, dementia communication strategies, avoidance of adverse events, alterations to the physical environment, and education of ED staff. Many recommendations are extrapolated from residential care settings. Review results indicate that there is minimal guidance for the care of PWD specific to the ED setting. There are no empirical studies of the care (assessment, interventions) of PWD in the ED. The existing (Level 7) recommendations lack a research base to support their effectiveness or adoption as evidence-based practice. There is a significant opportunity for research to identify and test ways to meet the needs of PWD in the ED to ensure a safe visit, accurate diagnosis, and prudent transfer to the most appropriate level of care. © 2012, Copyright the Authors Journal compilation © 2012, The American Geriatrics Society.

  9. Subnuclear localization, rates and effectiveness of UVC-induced unscheduled DNA synthesis visualized by fluorescence widefield, confocal and super-resolution microscopy.

    PubMed

    Pierzyńska-Mach, Agnieszka; Szczurek, Aleksander; Cella Zanacchi, Francesca; Pennacchietti, Francesca; Drukała, Justyna; Diaspro, Alberto; Cremer, Christoph; Darzynkiewicz, Zbigniew; Dobrucki, Jurek W

    2016-01-01

    Unscheduled DNA synthesis (UDS) is the final stage of the process of repair of DNA lesions induced by UVC. We detected UDS using a DNA precursor, 5-ethynyl-2'-deoxyuridine (EdU). Using wide-field, confocal and super-resolution fluorescence microscopy and normal human fibroblasts, derived from healthy subjects, we demonstrate that the sub-nuclear pattern of UDS detected via incorporation of EdU is different from that when BrdU is used as DNA precursor. EdU incorporation occurs evenly throughout chromatin, as opposed to just a few small and large repair foci detected by BrdU. We attribute this difference to the fact that BrdU antibody is of much larger size than EdU, and its accessibility to the incorporated precursor requires the presence of denatured sections of DNA. It appears that under the standard conditions of immunocytochemical detection of BrdU only fragments of DNA of various length are being denatured. We argue that, compared with BrdU, the UDS pattern visualized by EdU constitutes a more faithful representation of sub-nuclear distribution of the final stage of nucleotide excision repair induced by UVC. Using the optimized integrated EdU detection procedure we also measured the relative amount of the DNA precursor incorporated by cells during UDS following exposure to various doses of UVC. Also described is the high degree of heterogeneity in terms of the UVC-induced EdU incorporation per cell, presumably reflecting various DNA repair efficiencies or differences in the level of endogenous dT competing with EdU within a population of normal human fibroblasts.

  10. Discharge of Non-Acute Coronary Syndrome Chest Pain Patients From Emergency Care to an Advanced Nurse Practitioner-Led Chest Pain Clinic: A Cross-Sectional Study of Referral Source and Final Diagnosis.

    PubMed

    Ingram, Shirley J; McKee, Gabrielle; Quirke, Mary B; Kelly, Niamh; Moloney, Ashling

    Chest pain is a common presentation to emergency departments (EDs). Pathways for patients with non-acute coronary syndrome (ACS) chest pain are not optimal. An advanced cardiology nurse-led chest pain service was commenced to address this. The aim of the study was to assess the outcomes of non-ACS patients discharged from ED to an advanced cardiology nurse-led chest pain clinic and compare by referral type (nurse or ED physician). The service consisted of advanced cardiology nurse or ED physician consultation in the ED and discharge to advanced nurse-led chest pain clinic review less than 72 hours after discharge. Referrals were by the advanced nurses during consult hours and out-of-hours were by the ED physicians. Data were extracted from case notes. This was a 1-site cross-sectional study of patients attending the chest pain clinic over 2 years. Confirmed coronary disease was diagnosed in 24% of patients. Of the 1041 patients, 45% were referred by the advanced nurses, who referred significantly more patients who were older (56.5 years/52.3 years), had positive exercise stress test results (21%/12%), and were diagnosed with stable coronary artery disease (19%/11%) and less patients with musculoskeletal diagnosis (5%/13%) and other noncardiac pain (36%/45%). The study fills a gap in the literature on the follow up of non-ACS patients who present to ED and used advanced cardiology nursing expertise in the ED and chest pain clinic. The advanced nurse referred more patients who were diagnosed with coronary disease, reflecting the expertise, experience, and efficiency of the advanced cardiology nurse-led service.

  11. Subnuclear localization, rates and effectiveness of UVC-induced unscheduled DNA synthesis visualized by fluorescence widefield, confocal and super-resolution microscopy

    PubMed Central

    Pierzyńska-Mach, Agnieszka; Szczurek, Aleksander; Cella Zanacchi, Francesca; Pennacchietti, Francesca; Drukała, Justyna; Diaspro, Alberto; Cremer, Christoph; Darzynkiewicz, Zbigniew; Dobrucki, Jurek W.

    2016-01-01

    ABSTRACT Unscheduled DNA synthesis (UDS) is the final stage of the process of repair of DNA lesions induced by UVC. We detected UDS using a DNA precursor, 5-ethynyl-2′-deoxyuridine (EdU). Using wide-field, confocal and super-resolution fluorescence microscopy and normal human fibroblasts, derived from healthy subjects, we demonstrate that the sub-nuclear pattern of UDS detected via incorporation of EdU is different from that when BrdU is used as DNA precursor. EdU incorporation occurs evenly throughout chromatin, as opposed to just a few small and large repair foci detected by BrdU. We attribute this difference to the fact that BrdU antibody is of much larger size than EdU, and its accessibility to the incorporated precursor requires the presence of denatured sections of DNA. It appears that under the standard conditions of immunocytochemical detection of BrdU only fragments of DNA of various length are being denatured. We argue that, compared with BrdU, the UDS pattern visualized by EdU constitutes a more faithful representation of sub-nuclear distribution of the final stage of nucleotide excision repair induced by UVC. Using the optimized integrated EdU detection procedure we also measured the relative amount of the DNA precursor incorporated by cells during UDS following exposure to various doses of UVC. Also described is the high degree of heterogeneity in terms of the UVC-induced EdU incorporation per cell, presumably reflecting various DNA repair efficiencies or differences in the level of endogenous dT competing with EdU within a population of normal human fibroblasts. PMID:27097376

  12. Ethnographic analysis on the use of the electronic medical record for clinical handoff.

    PubMed

    Nelson, Philippa; Bell, Anthony J; Nathanson, Larry; Sanchez, Leon D; Fisher, Jonathan; Anderson, Philip D

    2017-12-01

    The objective of this study was to understand the social elements of clinical and organizational interactions of the key stakeholders in the specific context of an electronic dashboard used by the emergency department (ED) and inpatient medicine teams at the time of clinical referral and handover. An electronic handover function is utilised at the ED-inpatient interface at this institution and has given clinicians the ability to better communicate, monitor the department and strive to improve patient safety in streamline the delivery of care in the acute phase. This study uses an ethnographic qualitative research design incorporating semistructured interviews, participant observation on the ED floor and fieldwork notes. The setting for this research was in the ED at a tertiary University affiliated hospital. Triangulation was used to combine information obtained from multiple sources and information from fieldwork and interviews refined into useable chunks culminating in a thematic analysis. Thematic analysis yielded five central themes that reflected how the clinical staff utilised this IT system and why it had become embedded in the culture of clinical referral and handover. Efficient time management for improved patient flow was demonstrated, value added communication (at the interpersonal level), the building trust at the ED-inpatient interface, the maintenance of mutual respect across medical cultures and an overall enhancement of the quality of ED communication (in terms of the information available). A robust electronic handover process, resulted in an integrated approach to patient care by removing barriers to admission for medical inpatients, admitted via ED. The value proposition for patients was a more complete information transfer, both within the ED and between departments.

  13. Epidemiologic analysis of an urban, public emergency department's frequent users.

    PubMed

    Mandelberg, J H; Kuhn, R E; Kohn, M A

    2000-06-01

    To determine how the demographic, clinical, and utilization characteristics of emergency department (ED) frequent users differ from those of other ED patients. A cross-sectional and retrospective cohort study was performed using a database of all 348,858 visits to the San Francisco General Hospital ED during a five-year period (July 1, 1993, to June 30, 1998). A "frequent user" visited the ED five or more times in a 12-month period. Frequent users constituted 3.9% of ED patients but accounted for 20.5% of ED visits. The relative risk (RR) of frequent use was high among patients who were homeless (RR = 4.5), African American (RR = 1.8), and Medi-Cal sponsored (RR = 2.1). Frequent users were more likely to be seen for alcohol withdrawal (RR = 4.4), alcohol dependence (RR = 3.4), and alcohol intoxication (RR = 2.4). Frequent users were also more likely to visit for exacerbations of chronic conditions, including sickle cell anemia (RR = 8.0), renal failure (RR = 3.6), and chronic obstructive pulmonary disease (RR = 3.3). They were less likely to visit for all forms of trauma (RR = 0.43). Survival analysis showed that only 38% of frequent users for one year remained frequent users the next year. However, 56% of frequent users for two consecutive years remained frequent users in the third year. Frequent use of the ED reflects the urban social problems of homelessness, poverty, alcohol abuse, and chronic illness. Frequent use of the ED shows a high rate of decline from one year to the next. This rate of decline slows after the first year and suggests the existence of a smaller group of chronic frequent users.

  14. Effective emissivities of isothermal blackbody cavities calculated by the Monte Carlo method using the three-component bidirectional reflectance distribution function model.

    PubMed

    Prokhorov, Alexander

    2012-05-01

    This paper proposes a three-component bidirectional reflectance distribution function (3C BRDF) model consisting of diffuse, quasi-specular, and glossy components for calculation of effective emissivities of blackbody cavities and then investigates the properties of the new reflection model. The particle swarm optimization method is applied for fitting a 3C BRDF model to measured BRDFs. The model is incorporated into the Monte Carlo ray-tracing algorithm for isothermal cavities. Finally, the paper compares the results obtained using the 3C model and the conventional specular-diffuse model of reflection.

  15. Retrieval of optical properties of skin from measurement and modeling the diffuse reflectance

    NASA Astrophysics Data System (ADS)

    Douven, Lucien F. A.; Lucassen, Gerald W.

    2000-06-01

    We present results on the retrieval of skin optical properties obtained by fitting of measurements of the diffuse reflectance of human skin. Reflectance spectra are simulated using an analytical model based on the diffusion approximation. This model is implemented in a simplex fit routine. The skin optical model used consists of five layers representing epidermis, capillary blood plexus, dermis, deep blood plexus and hypodermis. The optical properties of each layer are assumed homogeneously distributed. The main optical absorbers included are melanin in epidermis and blood. The experimental setup consists of a HP photospectrometer equipped with a remote fiber head. Total reflectance spectra were measured in the 400 - 820 nm wavelength range on the volar underarm of 19 volunteers under various conditions influencing the blood content and oxygenation degree. Changes in the reflectance spectra were observed. Using the fit routine changes in blood content in the capillary blood plexus and in the deep blood plexus could be quantified. These showed different influences on the total reflectance. The method can be helpful to quantitatively assess changes in skin color appearance such as occurs in the treatment of port wine stains, blanching, skin irritation and tanning.

  16. Synthesis of CdS/ZnO/graphene composite with high-efficiency photoelectrochemical activities under solar radiation

    NASA Astrophysics Data System (ADS)

    Han, Weijia; Ren, Long; Qi, Xiang; Liu, Yundan; Wei, Xiaolin; Huang, Zongyu; Zhong, Jianxin

    2014-04-01

    A novel ternary CdS/ZnO/graphene composite has been successfully prepared by loading ZnO and CdS nanoparticles in graphene nanosheets via a facile one-step hydrothermal method. The microstructures and properties have been examined by X-ray diffraction (XRD), scanning electron microscopy with an energy dispersive spectroscope (EDS), transmission electron microscopy, Raman and UV-vis diffuse reflectance spectra (DRS). The characterization results reveal that the crystalline of the composite is very well, the graphene sheets were tightly coated with ZnO and CdS nanoparticles, and the light-harvesting was effectively strengthened. Taking photoelectrochemical test, the ternary CdS/ZnO/graphene composite exhibits enhanced photocatalytic activity compared with its foundation matrix binary composites and pure ZnO and CdS. The improved photocatalytic performance can be attributed to the enhanced light absorption, the extremely efficient charge separation, as well as superior durability of the ternary composite. It is proposed that graphene-based composites by coupling graphene to suitable, multiple semiconductors can not only greatly improve the capacity for photocatalytic, but also expand the exploration and utilization of graphene-based nanocomposites for energy conversion.

  17. Preparation of poly-o-phenylenediamine/TiO 2/fly-ash cenospheres and its photo-degradation property on antibiotics

    NASA Astrophysics Data System (ADS)

    Huo, Pengwei; Yan, Yongsheng; Li, Songtian; Li, Huaming; Huang, Weihong

    2010-03-01

    A series of poly-o-phenylenediamine/TiO 2/fly-ash cenospheres(POPD/TiO 2/fly-ash cenospheres) composites have been prepared from o-phenylenediamine and TiO 2/fly-ash cenospheres under various polymerization conditions. The properties of the samples were characterized by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), specific surface area (BET), X-ray diffraction (XRD), Fourier transform infrared (FT-IR) and UV-vis diffuse reflectance spectrum (UV-vis DRS). Photocatalytic activity was studied by degradation of antibiotics waste water under visible light. The results indicate that the photo-induced method is viable for preparing modified photocatalysts, and the modified photocatalysts have good absorption in visible light range. The photocatalysts of POPD/TiO 2/fly-ash cenospheres which have good performance are prepared at pH 3 and 4, and the polymerized time around 40 min. When the photocatalysts are prepared under the conditions of pH 3 and polymerized time 40 min, the degradation rate of roxithromycin waste water could reach near 60%, and it indicates that the way of POPD modified TiO 2/fly-ash cenospheres to degrade the antibiotics waste water is viable.

  18. Biosynthesis and characterization of ZnO nanoparticles using the aqueous leaf extract of Imperata cylindrica L.

    NASA Astrophysics Data System (ADS)

    Saputra, I. S.; Yulizar, Y.

    2017-04-01

    ZnO nanoparticles (ZnO NPs) were biosynthesized.The growth was observed by a sol-gel method. ZnO were successfully formed through the reaction of zinc nitrate tetrahydrate Zn(NO3)2.4H2O precursor with aqueous leaf extract of Imperata cylindrica L (ICL). The structural and optical properties of ZnO were investigated. The as-synthesized products were characterized by UV-Visible (UV-Vis), UV diffuse reflectance spectroscopy (UV-DRS), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDS). UV-Vis absorption data showed hydrolysis and characteristic of absorption peak at 300 nm of Zn(OH)2. UV-DRS confirmed that ZnO NPs has the indirect band gap at 3.13 eV. FTIR spectrum revealed the functional groups and indicated the presence of protein as the capping and stabilizing agent on the ZnO surface. Powder XRD studies indicated the formation of pure wurtzite hexagonal structure with particle size of 11.9 nm. The detailed morphological and structural characterizations revealed that the synthesized products were hexagonal nanochip.

  19. Template-Free Hydrothermal Synthesis, Mechanism, and Photocatalytic Properties of Core-Shell CeO2 Nanospheres

    NASA Astrophysics Data System (ADS)

    Li, Huijie; Meng, Fanming; Gong, Jinfeng; Fan, Zhenghua; Qin, Rui

    2018-03-01

    CeO2 nanospheres with the core-shell nanostructure have been successfully synthesized by a template-free hydrothermal method. The structures, morphologies and optical properties of core-shell CeO2 nanospheres were analyzed by X-ray diffraction (XRD), TG, Fourier transform infrared spectroscopy, XRD, EDS, SAED, scanning electron microscopy and transmission electron microscopy, UV-Vis diffuse reflectance spectra, Raman analyses. The degradation efficiencies of core-shell CeO2 nanospheres for methyl orange were as high as 93.49, 95.67 and 98.28% within 160 min, and the rates of photo degradation of methyl orange by core-shell CeO2 nanospheres under UV-light were 0.01693, 0.01782 and 0.02375 min-1. Methyl orange was degraded in photocatalytic oxidation processes, which mainly gave the credit to a large number of reactive species including h+, surface superoxide species ·O2 -, and ·OH radicals. The core-shell structure, small crystallite size and the conversion between Ce3+ and Ce4+ of CeO2 nanospheres were of importance for its catalytic activity. These results demonstrated the possibility of improving the efficient catalysts of the earth abundant CeO2 catalysts.

  20. Photoelectrochemical Water Splitting Properties of Ti-Ni-Si-O Nanostructures on Ti-Ni-Si Alloy

    PubMed Central

    Dong, Zhenbiao; Ning, Congqin

    2017-01-01

    Ti-Ni-Si-O nanostructures were successfully prepared on Ti-1Ni-5Si alloy foils via electrochemical anodization in ethylene glycol/glycerol solutions containing a small amount of water. The Ti-Ni-Si-O nanostructures were characterized by field-emission scanning electron microscopy (FE-SEM), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), and diffuse reflectance absorption spectra. Furthermore, the photoelectrochemical water splitting properties of the Ti-Ni-Si-O nanostructure films were investigated. It was found that, after anodization, three different kinds of Ti-Ni-Si-O nanostructures formed in the α-Ti phase region, Ti2Ni phase region, and Ti5Si3 phase region of the alloy surface. Both the anatase and rutile phases of Ti-Ni-Si-O oxide appeared after annealing at 500 °C for 2 h. The photocurrent density obtained from the Ti-Ni-Si-O nanostructure photoanodes was 0.45 mA/cm2 at 0 V (vs. Ag/AgCl) in 1 M KOH solution. The above findings make it feasible to further explore excellent photoelectrochemical properties of the nanostructure-modified surface of Ti-Ni-Si ternary alloys. PMID:29088083

  1. Photoelectrochemical Water Splitting Properties of Ti-Ni-Si-O Nanostructures on Ti-Ni-Si Alloy.

    PubMed

    Li, Ting; Ding, Dongyan; Dong, Zhenbiao; Ning, Congqin

    2017-10-31

    Ti-Ni-Si-O nanostructures were successfully prepared on Ti-1Ni-5Si alloy foils via electrochemical anodization in ethylene glycol/glycerol solutions containing a small amount of water. The Ti-Ni-Si-O nanostructures were characterized by field-emission scanning electron microscopy (FE-SEM), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), and diffuse reflectance absorption spectra. Furthermore, the photoelectrochemical water splitting properties of the Ti-Ni-Si-O nanostructure films were investigated. It was found that, after anodization, three different kinds of Ti-Ni-Si-O nanostructures formed in the α-Ti phase region, Ti₂Ni phase region, and Ti₅Si₃ phase region of the alloy surface. Both the anatase and rutile phases of Ti-Ni-Si-O oxide appeared after annealing at 500 °C for 2 h. The photocurrent density obtained from the Ti-Ni-Si-O nanostructure photoanodes was 0.45 mA/cm² at 0 V (vs. Ag/AgCl) in 1 M KOH solution. The above findings make it feasible to further explore excellent photoelectrochemical properties of the nanostructure-modified surface of Ti-Ni-Si ternary alloys.

  2. Photocatalytic detoxification of Acid Red 18 by modified ZnO catalyst under sunlight irradiation

    NASA Astrophysics Data System (ADS)

    Senthilraja, A.; Subash, B.; Dhatshanamurthi, P.; Swaminathan, M.; Shanthi, M.

    2015-03-01

    In this work, hybrid structured Bi-Au-ZnO composite was prepared by precipitation-decomposition method. This method is mild, economical and efficient. Bi-Au-ZnO was characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), transmission electron microscopy (TEM), energy dispersive spectrum (EDS), diffuse reflectance spectra (DRS), photoluminescence spectra (PL) and BET surface area measurements. Photocatalytic activity of Bi-Au-ZnO was evaluated by irradiating the Acid Red 18 (AR 18) dye solution under sun light. Heterostructured Bi-Au-ZnO photocatalyst showed higher photocatalytic activity than those of individual Bi-ZnO, Au-ZnO, bare ZnO, and TiO2-P25 at pH 11. The effects of operational parameters such as the amount of catalyst dosage, dye concentration, initial pH on photo mineralization of AR 18 dye have been analyzed. The mineralization of AR 18 has been confirmed by chemical oxygen demand (COD) measurements. A possible mechanism is proposed for the degradation of AR 18 under sun light. Finally, Bi-Au-ZnO heterojunction photocatalyst was more stable and could be easily recycled several times opening a new avenue for potential industrial applications.

  3. Monitoring of caffeine consumption effect on skin blood properties by diffuse reflectance spectroscopy

    NASA Astrophysics Data System (ADS)

    Milanic, Matija; Marin, Ana; Stergar, Jost; Verdel, Nina; Majaron, Boris

    2017-07-01

    Caffeine is the most widely consumed psychoactive substance in the world. It affects many tissues and organs, in particular central nervous system, heart, and blood vessels. The effect of caffeine on vascular smooth muscle cells is an initial transient contraction followed by significant vasodilatation. In this study we investigate the use of diffuse reflectance spectroscopy (DRS) for monitoring of vascular changes in human skin induced by caffeine consumption. DRS spectra were recorded on volar sides of the forearms of ten healthy volunteers at time delays of 0, 30, 60, 120, and 180 minutes after consumption of caffeine, while one subject served as a negative control. Analytical diffusion approximation solutions for diffuse reflectance from three-layer structures were used to assess skin composition (e.g., dermal blood volume fraction and oxygen saturation) by fitting to experimental data. The results demonstrate that cutaneous vasodynamics induced by caffeine consumption can be monitored by DRS, while changes in the control subject not consuming caffeine were insignificant.

  4. Method for Calculating the Optical Diffuse Reflection Coefficient for the Ocular Fundus

    NASA Astrophysics Data System (ADS)

    Lisenko, S. A.; Kugeiko, M. M.

    2016-07-01

    We have developed a method for calculating the optical diffuse reflection coefficient for the ocular fundus, taking into account multiple scattering of light in its layers (retina, epithelium, choroid) and multiple refl ection of light between layers. The method is based on the formulas for optical "combination" of the layers of the medium, in which the optical parameters of the layers (absorption and scattering coefficients) are replaced by some effective values, different for cases of directional and diffuse illumination of the layer. Coefficients relating the effective optical parameters of the layers and the actual values were established based on the results of a Monte Carlo numerical simulation of radiation transport in the medium. We estimate the uncertainties in retrieval of the structural and morphological parameters for the fundus from its diffuse reflectance spectrum using our method. We show that the simulated spectra correspond to the experimental data and that the estimates of the fundus parameters obtained as a result of solving the inverse problem are reasonable.

  5. Characterization of LANDSAT Panels Using the NIST BRDF Scale from 1100 nm to 2500 nm

    NASA Technical Reports Server (NTRS)

    Markham, Brian; Tsai, Benjamin K.; Allen, David W.; Cooksey, Catherine; Yoon, Howard; Hanssen, Leonard; Zeng, Jinan; Fulton, Linda; Biggar, Stuart; Markham, Brian

    2010-01-01

    Many earth observing sensors depend on white diffuse reflectance standards to derive scales of radiance traceable to the St Despite the large number of Earth observing sensors that operate in the reflective solar region of the spectrum, there has been no direct method to provide NIST traceable BRDF measurements out to 2500 rim. Recent developments in detector technology have allowed the NIST reflectance measurement facility to expand the operating range to cover the 250 nm to 2500 nm range. The facility has been modified with and additional detector using a cooled extended range indium gallium arsenide (Extended InGaAs) detector. Measurements were made for two PTFE white diffuse reflectance standards over the 1100 nm to 2500 nm region at a 0' incident and 45' observation angle. These two panels will be used to support the OLI calibration activities. An independent means of verification was established using a NIST radiance transfer facility based on spectral irradiance, radiance standards and a diffuse reflectance plaque. An analysis on the results and associated uncertainties will be discussed.

  6. [Comparative study of reflectance spectroscopy of women's acupoints around menstruation].

    PubMed

    Jiang, Xing-Hui; Liu, Han-Ping; Guo, Zhou-Yi; Meng, Yao-Yong; Zeng, Chang-Chun; Liu, Song-Hao

    2010-12-01

    Acupoint was reaction of viscera and its optical parameter was an important characteristic of tissue. In the present work, in order to discuss specificity of acupuncture on the response of qi and blood in human body, we compared the diffuse reflectance of Taichong (LV3), Taibai (SP3), and Chongyang (ST42) before, during and after menstruation. All the acupoints had the same shape of the spectrum and troughs were all at 423.16, 544.06 and 577.47 nm. The values of reflectance during menstruation were greater than before and after menstruation, especially for SP3 and ST42 (P < 0.05). SP3 and ST42 were more sensitive to the changes of qi and blood than LV3, and it was asymmetric and we found no evidence for the imbalance of the left side and right. These results indicated that acupoint diffuse reflectance changed with qi and blood, and that SP3 and ST42 had close relationship with menstruation. Diffuse reflectance may be possibly used in the quantitative analysis of qi and blood.

  7. Identity Processes and Statuses in Patients with and without Eating Disorders.

    PubMed

    Verschueren, Margaux; Luyckx, Koen; Kaufman, Erin A; Vansteenkiste, Maarten; Moons, Philip; Sleuwaegen, Ellen; Berens, Ann; Schoevaerts, Katrien; Claes, Laurence

    2017-01-01

    Problems with identity formation are associated with a range of psychiatric disorders. Yet, the mechanisms underlying such problems and how they are refined into specific diagnostic presentations require further investigation. The present study investigated identity processes among 123 women with eating disorders (ED) and age-matched community controls via a newly developed identity model. Several clinical outcome variables were assessed. Patients with ED scored lower on committing to and identifying with identity-related choices and scored higher on maladaptive or ruminative exploration, identity diffusion and identity disorder. They also experienced less identity achievement as compared with controls. The identity disorder status was associated with the highest scores on anxiety, depression, borderline personality disorder symptoms, and non-suicidal self-injury and the lowest scores on need satisfaction. Results indicate that patients with ED experience more identity problems than community controls and those captured by an identity disorder status experience the most problematic psychosocial functioning. Copyright © 2016 John Wiley & Sons, Ltd and Eating Disorders Association. © 2016 John Wiley & Sons, Ltd and Eating Disorders Association.

  8. Photothermal Radiometry and Diffuse Reflectance Analysis of Thermally Treated Bones

    NASA Astrophysics Data System (ADS)

    Trujillo, S.; Martínez-Torres, P.; Quintana, P.; Alvarado-Gil, Juan Jose

    2010-05-01

    Different fields such as archaeology, biomedicine, forensic science, and pathology involve the analysis of burned bones. In this work, the effects of successive thermal treatments on pig long bones, measured by photothermal radiometry and diffuse reflectance are reported. Measurements were complemented by X-ray diffraction and infrared spectroscopy. Samples were thermally treated for 1 h within the range of 25 °C to 350 °C. The thermal diffusivity and reflectance increase in the low-temperature range, reaching a maximum around 125 °C and decaying at higher temperatures. These results are the consequence of complex modifications occurring in the inorganic and organic bone structure. For lower temperatures dehydration, dehydroxilation, and carbonate loss processes are dominant, followed by collagen denaturing and decompositions, which have an influence on the bone microstructure.

  9. Study of the oxidation of uranium by external and diffuse reflectance FTIR spectroscopy using remote-sensing and evacuable cell techniques

    NASA Astrophysics Data System (ADS)

    Powell, G. L.; Dobbins, A.; Cristy, S. S.; Cliff, T. L.; Meyer, H. M., III; Lucania, J.; Milosevic, Milan

    1994-01-01

    This report describes the application of reflectance FTIR spectroscopy to the measurement of the oxidation rate of uranium by environmental gases near room temperature. It also describes very efficient evacuable cells designed for 75 degree(s) external reflectance with polarized light and for diffuse reflectance using mid-infrared FTIR spectroscopy. These cells, along with functionally similar remote sensing accessories, have been applied to the study of the oxidation of uranium metal in air, oxygen, and water vapor by precisely measuring the 575 cm-1 band of UO2 and other properties of the corrosion film such as absorbed water and reflective losses caused by film degradation related to pitting or nucleation phenomena.

  10. Light polarization measurements - A method to determine the specular and diffuse light-scattering properties of both leaves and plant canopies

    NASA Technical Reports Server (NTRS)

    Vanderbilt, V. C.; Grant, L.

    1984-01-01

    The contributions of diffuse and specular reflection to the total canopy reflection of sunlight are determined experimentally for wheat at two stages of development using spectroradiometer measurements obtained at 13 wavelengths in the 480-720-nm range with a polarizing film in maximum and minimum signal-amplitude positions. The data and computation techniques are presented in tables, diagrams, and graphs, and the need to take specular reflection into account in constructing models of light/canopy interaction is stressed.

  11. Ultraviolet stability and contamination analysis of Spectralon diffuse reflectance material

    NASA Technical Reports Server (NTRS)

    Stiegman, Albert E.; Bruegge, Carol J.; Springsteen, Arthur W.

    1993-01-01

    A detailed chemical analysis was carried out on Spectralon, a highly Lambertian, diffuse reflectance material. Results of this investigation unambiguously identified the presence of an organic (hydrocarbon) impurity intrinsic to the commercial material. This impurity could be removed by a vacuum bake-out procedure and was identified as the cause of optical changes (degradation) that occur in the material when exposed to UV light. It was found that when this impurity was removed, the Spectralon material was photochemically stable and maintained its reflectance properties even after extensive solar UV exposure.

  12. Impact of ED management on hospital quality measures: the negative case of atrial fibrillation.

    PubMed

    Piela, Nicole E; Sacchetti, Alfred; Sholevar, Darius; Blaber, Reginald; Levi, Steven

    2013-05-01

    Emergency department (ED) cardioversion and discharge of atrial fibrillation (AF) is an evolving treatment. Emergency department cardioversion patients have few comorbidities, and their discharge directly from the ED leads to a sicker in-patient population of AF patients. This study examines whether the quality care markers, hospital charges (HC) and length of stay (LOS), negatively reflect the practice of ED cardioversion. Median HC and LOS were determined for 2 different quality assessment reporting models. In a standard model (SM), patients discharged from the ED were not included in any hospital statistics and only admitted, or observation patients were used to calculate the HC and LOS of AF patients. In an inclusive model (IM), patients discharged from the ED were also included in the hospital statistics but given the same LOS as observation patients. Differences across medians were analyzed using Wilcoxon rank sum tests. A total of 312 patients were evaluated for AF over an 18-month period. Of these, 197 (62%) were admitted, 21 (7%) were placed in observation status, and 95 (31%) were discharged from the ED. Median values for LOS were 3 days (interquartile range [IQR], 1-5) for the SM and 1 day (IQR, 0-4) for the IM. Median values for HC were $33062 (IQR, $19267-$60614) for the SM and $20059 (IQR, $4249-$47195) for the IM. Emergency department cardioversion selects out a less sick cohort of patients whose removal from a hospital's admission numbers negatively skews quality performance profiles. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Radiative transfer simulations of the two-dimensional ocean glint reflectance and determination of the sea surface roughness.

    PubMed

    Lin, Zhenyi; Li, Wei; Gatebe, Charles; Poudyal, Rajesh; Stamnes, Knut

    2016-02-20

    An optimized discrete-ordinate radiative transfer model (DISORT3) with a pseudo-two-dimensional bidirectional reflectance distribution function (BRDF) is used to simulate and validate ocean glint reflectances at an infrared wavelength (1036 nm) by matching model results with a complete set of BRDF measurements obtained from the NASA cloud absorption radiometer (CAR) deployed on an aircraft. The surface roughness is then obtained through a retrieval algorithm and is used to extend the simulation into the visible spectral range where diffuse reflectance becomes important. In general, the simulated reflectances and surface roughness information are in good agreement with the measurements, and the diffuse reflectance in the visible, ignored in current glint algorithms, is shown to be important. The successful implementation of this new treatment of ocean glint reflectance and surface roughness in DISORT3 will help improve glint correction algorithms in current and future ocean color remote sensing applications.

  14. Radiative Transfer Simulations of the Two-Dimensional Ocean Glint Reflectance and Determination of the Sea Surface Roughness

    NASA Technical Reports Server (NTRS)

    Lin, Zhenyi; Li, Wei; Gatebe, Charles; Poudyal, Rajesh; Stamnes, Knut

    2016-01-01

    An optimized discrete-ordinate radiative transfer model (DISORT3) with a pseudo-two-dimensional bidirectional reflectance distribution function (BRDF) is used to simulate and validate ocean glint reflectances at an infrared wavelength (1036 nm) by matching model results with a complete set of BRDF measurements obtained from the NASA cloud absorption radiometer (CAR) deployed on an aircraft. The surface roughness is then obtained through a retrieval algorithm and is used to extend the simulation into the visible spectral range where diffuse reflectance becomes important. In general, the simulated reflectances and surface roughness information are in good agreement with the measurements, and the diffuse reflectance in the visible, ignored in current glint algorithms, is shown to be important. The successful implementation of this new treatment of ocean glint reflectance and surface roughness in DISORT3 will help improve glint correction algorithms in current and future ocean color remote sensing applications.

  15. Classification of road sign type using mobile stereo vision

    NASA Astrophysics Data System (ADS)

    McLoughlin, Simon D.; Deegan, Catherine; Fitzgerald, Conor; Markham, Charles

    2005-06-01

    This paper presents a portable mobile stereo vision system designed for the assessment of road signage and delineation (lines and reflective pavement markers or "cat's eyes"). This novel system allows both geometric and photometric measurements to be made on objects in a scene. Global Positioning System technology provides important location data for any measurements made. Using the system it has been shown that road signs can be classfied by nature of their reflectivity. This is achieved by examining the changes in the reflected light intensity with changes in range (facilitated by stereo vision). Signs assessed include those made from retro-reflective materials, those made from diffuse reflective materials and those made from diffuse reflective matrials with local illumination. Field-testing results demonstrate the systems ability to classify objects in the scene based on their reflective properties. The paper includes a discussion of a physical model that supports the experimental data.

  16. The role of the Ti and Mo barrier layer in Ti/Al metallization to AlGaN/GaN heterostructures at identical process conditions: a structural and chemical characterization

    NASA Astrophysics Data System (ADS)

    Chandran, Narendraraj; Kolakieva, Lilyana; Kakanakov, Roumen; Polychroniadis, E. K.

    2015-11-01

    The composition and structure of TiAl-based metallizations have been investigated depending on the Ti and Mo barriers. The lowest contact resistivity of 4 × 10-6 Ω.cm2 for a Ti barrier and 7 × 10-6 Ω.cm2 for a Mo barrier is obtained at a Ti/Al ratio of 0.43 after annealing at 800 °C. The scanning transmission electron microscope (STEM) and energy dispersive spectroscopy (EDS) analyses reveal that Mo is not an effective barrier for the Au in-diffusion and Al out of diffusion during annealing. The intensive diffusion processes lead to the formation of the semimetal TiN compound at the interface and intermetallic phases of Au, Al, and Ti, the structure and composition of which depend on the barrier metal.

  17. Teaching systems thinking to 4th and 5th graders using Environmental Dashboard display technology.

    PubMed

    Clark, Shane; Petersen, John E; Frantz, Cindy M; Roose, Deborah; Ginn, Joel; Rosenberg Daneri, Daniel

    2017-01-01

    Tackling complex environmental challenges requires the capacity to understand how relationships and interactions between parts result in dynamic behavior of whole systems. There has been convincing research that these "systems thinking" skills can be learned. However, there is little research on methods for teaching these skills to children or assessing their impact. The Environmental Dashboard is a technology that uses "sociotechnical" feedback-information feedback designed to affect thought and behavior. Environmental Dashboard (ED) combines real-time information on community resource use with images and words that reflect pro-environmental actions of community members. Prior research indicates that ED supports the development of systems thinking in adults. To assess its impact on children, the technology was installed in a primary school and children were passively exposed to ED displays. This resulted in no measurable impact on systems thinking skills. The next stage of this research examined the impact of actively integrating ED into lessons on electricity in 4th and 5th grade. This active integration enhanced both content-related systems thinking skills and content retention.

  18. Teaching systems thinking to 4th and 5th graders using Environmental Dashboard display technology

    PubMed Central

    Clark, Shane; Frantz, Cindy M.; Roose, Deborah; Ginn, Joel; Rosenberg Daneri, Daniel

    2017-01-01

    Tackling complex environmental challenges requires the capacity to understand how relationships and interactions between parts result in dynamic behavior of whole systems. There has been convincing research that these “systems thinking” skills can be learned. However, there is little research on methods for teaching these skills to children or assessing their impact. The Environmental Dashboard is a technology that uses “sociotechnical” feedback–information feedback designed to affect thought and behavior. Environmental Dashboard (ED) combines real-time information on community resource use with images and words that reflect pro-environmental actions of community members. Prior research indicates that ED supports the development of systems thinking in adults. To assess its impact on children, the technology was installed in a primary school and children were passively exposed to ED displays. This resulted in no measurable impact on systems thinking skills. The next stage of this research examined the impact of actively integrating ED into lessons on electricity in 4th and 5th grade. This active integration enhanced both content-related systems thinking skills and content retention. PMID:28448586

  19. Diffusely reflecting paints including polytetrafluoroethylene and method of manufacture

    NASA Technical Reports Server (NTRS)

    Schutt, J. B.; Shai, M. C. (Inventor)

    1985-01-01

    The invention pertains to a high diffuse, reflective paint comprising an alcohol soluble binder, polytetrafluoroethylene (TFE) and an alcohol for coating a substrate and forming an optical reference with a superior Lambertian characteristic. A method for making the paint by first mixing the biner and alcohol, and thereafter by mixing in outgassed TFE is described. A wetting agent may be employed to aid the mixing process.

  20. Improvement of direct determination of trace nickel in environmental samples by diffuse reflection spectroscopy using chromaticity characteristics.

    PubMed

    Ershova, N I; Ivanov, V M

    2000-05-01

    Cellulose and chromaton-N-super as solid supports for direct determination of the immobilized nickel complexes with dimethylglyoxime and benzyldioxime by diffuse reflection spectroscopy were compared. The advantage of chromaton-N-super with use of benzyldioxime is shown. Detection limit is 0.02 microg/mL. The proposed method was applied for the analysis of soil.

  1. Review Essay: Pondering Pedagogical Paradoxes

    ERIC Educational Resources Information Center

    Spencer, Leland G.

    2015-01-01

    Herein, Leland Spencer provides a review of four book selections while reflecting on paradoxes regularly faced by feminist teachers (and scholars, activists, and thinkers). The books include: (1) Bradley, Harriet. "Gender." Cambridge: Polity, 2012. Print; (2) Murphy, Michael J., and Elizabeth N. Ribarsky, eds. "Activities for…

  2. Two years comparative studies on biological effects of environmental UV radiation

    NASA Astrophysics Data System (ADS)

    Grof, P.; Ronto, Gyorgyi; Gaspar, S.; Berces, A.; Szabo, Laszlo D.

    1994-07-01

    A method has been developed for determination of the biologically effective UV dose based on T7 phage as biosensor. In field experiments clockwork driven telescope has been used for determining doses from direct and global (direct plus diffuse) solar radiation. On fine summer days at mid-latitude this arrangement allowed the following comparisons: measured doses from direct and global radiation obtained at the same time and measuring site reflecting the biological importance of diffuse radiation; direct and global radiation obtained at the same time and measuring site reflecting the biological importance of diffuse radiation; direct and global doses obtained at the same time on different measuring sites (downtown, suburb, outside the town) reflecting the differences caused by air quality; direct and global doses obtained on the same measuring place, in summertime of two different years reflecting the importance of the long-term measurements for estimating the biological risk caused by increased UV-B radiation; measured data and model calculations.

  3. Polarimetric phenomenology in the reflective regime: a case study using polarized hyperspectral data

    NASA Astrophysics Data System (ADS)

    Gibney, Mark

    2016-05-01

    Understanding the phenomenology of polarimetric data is necessary if we want to obtain the maximum benefit when we exploit that data. To first order, polarimetric phenomenology is driven by two things; the target material type (specular or diffuse) and the illuminating source (point (sun) or extended (body emission)). Polarimetric phenomenology can then be broken into three basic categories; ([specular material/sun source], [diffuse/sun], [specular/body]) where we have assigned body emission to the IR passband where materials are generally specular. The task of interest determines the category of interest since the task determines the dominant target material and the illuminating source (eg detecting diffuse targets under trees in VNIR = [diffuse/sun] category). In this paper, a specific case study for the important [diffuse/sun] category will be presented. For the reflective regime (0.3 - 3.0um), the largest polarimetric signal is obtained when the sun illuminates a significant portion of the material BRDF lobe. This naturally points us to problems whose primary target materials are diffuse since the BRDF lobe for specular materials is tiny (low probability of acquiring on the BRDF lobe) and glinty (high probability of saturating the sensor when on lobe). In this case study, we investigated signatures of solar illuminated diffuse paints acquired by a polarimetric hyperspectral sensor. We will discuss the acquisition, reduction and exploitation of that data, and use it to illustrate the primary characteristics of reflective polarimetric phenomenology.

  4. Preliminary results of BTDF calibration of transmissive solar diffusers for remote sensing

    NASA Astrophysics Data System (ADS)

    Georgiev, Georgi T.; Butler, James J.; Thome, Kurt; Cooksey, Catherine; Ding, Leibo

    2016-09-01

    Satellite instruments operating in the reflected solar wavelength region require accurate and precise determination of the optical properties of their diffusers used in pre-flight and post-flight calibrations. The majority of recent and current space instruments use reflective diffusers. As a result, numerous Bidirectional Reflectance Distribution Function (BRDF) calibration comparisons have been conducted between the National Institute of Standards and Technology (NIST) and other industry and university-based metrology laboratories. However, based on literature searches and communications with NIST and other laboratories, no Bidirectional Transmittance Distribution Function (BTDF) measurement comparisons have been conducted between National Measurement Laboratories (NMLs) and other metrology laboratories. On the other hand, there is a growing interest in the use of transmissive diffusers in the calibration of satellite, air-borne, and ground-based remote sensing instruments. Current remote sensing instruments employing transmissive diffusers include the Ozone Mapping and Profiler Suite instrument (OMPS) Limb instrument on the Suomi-National Polar-orbiting Partnership (S-NPP) platform,, the Geostationary Ocean Color Imager (GOCI) on the Korea Aerospace Research Institute's (KARI) Communication, Ocean, and Meteorological Satellite (COMS), the Ozone Monitoring Instrument (OMI) on NASA's Earth Observing System (EOS) Aura platform, the Tropospheric Emissions: Monitoring of Pollution (TEMPO) instrument and the Geostationary Environmental Monitoring Spectrometer (GEMS).. This ensemble of instruments requires validated BTDF measurements of their onboard transmissive diffusers from the ultraviolet through the near infrared. This paper presents the preliminary results of a BTDF comparison between the NASA Diffuser Calibration Laboratory (DCL) and NIST on quartz and thin Spectralon samples.

  5. Practical Implications of the Use of Aluminide Coatings for the Corrosion Protection of Superalloys in Gas Turbines

    DTIC Science & Technology

    1984-04-01

    Strategic Materials Usage. Practical Implications of the Use of Aluminide Coatings for the Corrosion Protection of Superalloys in Gas Turbines. Coatings...requirements of using aluminide coatings, the processes currently commercially available, the compatabi1ity of aluminide coatings with...components, it is the intention of this paper to concentrate on those ed by reaction or diffusion type processes, In particular the aluminides

  6. Center for Innovative Minimally Invasive Therapy (CIMIT)

    DTIC Science & Technology

    2004-10-01

    diffuse through to deeper tissue to underlying capillaries. The same principle can be applied to oral drug delivery. Using microfabrication techniques...Steven L. The Effects of Testing Environment on the Viscoelastic Properties of Soft Tissues . In S. Cotin and D. Metaxas (Eds.): ISMS 2003, LNCS 3078, pp. 9...cardiomyocytes in mammals. Regeneration of myocardial tissue is an actively developing area of research aiming to restore cardiac function. We hypothesized that a

  7. Asymptotic Methods Especially in Combustion.

    DTIC Science & Technology

    1981-11-01

    1980.) Invited paper. 101. G.S.S. Ludford & Asok K. Sen: Burning rate maximum of a plane premixed flame. Proceedings of the Seventh International...Reactive Systems, ed. by J. Ray Bowen, N. Manson, Antoni K. Ompenheim, and R.I. Soloukhin.) 102. G.S.S. Ludford: Premixed cylindrical flames...106. Asok K. Sen & 0.S.S. Ludford: Effects of mass diffusion on the burning rate of non-4ilute mixtures. Proceedings of the Eighteenth Symposium

  8. Discovery of the linear region of Near Infrared Diffuse Reflectance spectra using the Kubelka-Munk theory

    NASA Astrophysics Data System (ADS)

    Dai, Shengyun; Pan, Xiaoning; Ma, Lijuan; Huang, Xingguo; Du, Chenzhao; Qiao, Yanjiang; Wu, Zhisheng

    2018-05-01

    Particle size is of great importance for the quantitative model of the NIR diffuse reflectance. In this paper, the effect of sample particle size on the measurement of harpagoside in Radix Scrophulariae powder by near infrared diffuse (NIR) reflectance spectroscopy was explored. High-performance liquid chromatography (HPLC) was employed as a reference method to construct the quantitative particle size model. Several spectral preprocessing methods were compared, and particle size models obtained by different preprocessing methods for establishing the partial least-squares (PLS) models of harpagoside. Data showed that the particle size distribution of 125-150 μm for Radix Scrophulariae exhibited the best prediction ability with R2pre=0.9513, RMSEP=0.1029 mg·g-1, and RPD = 4.78. For the hybrid granularity calibration model, the particle size distribution of 90-180 μm exhibited the best prediction ability with R2pre=0.8919, RMSEP=0.1632 mg·g-1, and RPD = 3.09. Furthermore, the Kubelka-Munk theory was used to relate the absorption coefficient k (concentration-dependent) and scatter coefficient s (particle size-dependent). The scatter coefficient s was calculated based on the Kubelka-Munk theory to study the changes of s after being mathematically preprocessed. A linear relationship was observed between k/s and absorption A within a certain range and the value for k/s was greater than 4. According to this relationship, the model was more accurately constructed with the particle size distribution of 90-180 μm when s was kept constant or in a small linear region. This region provided a good reference for the linear modeling of diffuse reflectance spectroscopy. To establish a diffuse reflectance NIR model, further accurate assessment should be obtained in advance for a precise linear model.

  9. Spectral distribution of UV range diffuse reflectivity for Si+ ion implanted polymers

    NASA Astrophysics Data System (ADS)

    Balabanov, S.; Tsvetkova, T.; Borisova, E.; Avramov, L.; Bischoff, L.

    2008-05-01

    The analysis of the UV range spectral characteristics can supply additional information on the formed sub-surface buried layer with implanted dopants. The near-surface layer (50÷150 nm) of bulk polymer samples have been implanted with silicon (Si+) ions at low energies (E = 30 keV) and a wide range of ion doses (D = 1.1013 ÷ 1, 2.1017 cm-2). The studied polymer materials were: ultra-high-molecular-weight polyethylene (UHMWPE), poly-methyl-metacrylate (PMMA) and poly-tetra-fluor-ethylene (PTFE). The diffuse optical reflectivity spectra Rd = f(λ) of the ion implanted samples have been measured in the UV range (λ = 220÷350 nm). In this paper the dose dependences of the size and sign of the diffuse optical reflectivity changes λRd = f(D) have been analysed.

  10. Prepreg cure monitoring using diffuse reflectance-FTIR. [Fourier Transform Infrared Technique

    NASA Technical Reports Server (NTRS)

    Young, P. R.; Chang, A. C.

    1984-01-01

    An in situ diffuse reflectance-Fourier transform infrared technique was developed to determine infrared spectra of graphite fiber prepregs as they were being cured. A bismaleimide, an epoxy, and addition polyimide matrix resin prepregs were studied. An experimental polyimide adhesive was also examined. Samples were positioned on a small heater at the focal point of diffuse reflectance optics and programmed at 15 F/min while FTIR spectra were being scanned, averaged, and stored. An analysis of the resulting spectra provided basic insights into changes in matrix resin molecular structure which accompanied reactions such as imidization and crosslinking. An endo-exothermal isomerization involving reactive end-caps was confirmed for the addition polyimide prepregs. The results of this study contribute to a fundamental understanding of the processing of composites and adhesives. Such understanding will promote the development of more efficient cure cycles.

  11. Developments in the realization of diffuse reflectance scales at NPL

    NASA Astrophysics Data System (ADS)

    Chunnilall, Christopher J.; Clarke, Frank J. J.; Shaw, Michael J.

    2005-08-01

    The United Kingdom scales for diffuse reflectance are realized using two primary instruments. In the 360 nm to 2.5 μm spectral region the National Reference Reflectometer (NRR) realizes absolute measurement of reflectance and radiance factor by goniometric measurements. Hemispherical reflectance scales are obtained through the spatial integration of these goniometric measurements. In the mid-infrared region (2.5 μm - 55 μm) the hemispherical reflectance scale is realized by the Absolute Hemispherical Reflectometer (AHR). This paper describes some of the uncertainties resulting from errors in aligning the NRR and non-ideality in sample topography, together with its use to carry out measurements in the 1 - 1.6 μm region. The AHR has previously been used with grating spectrometers, and has now been coupled to a Fourier transform spectrometer.

  12. Why a disaster is not just normal business ramped up: Disaster response among ED nurses.

    PubMed

    Hammad, Karen S; Arbon, Paul; Gebbie, Kristine; Hutton, Alison

    2017-11-15

    The emergency department (ED) is a familiar place for the emergency nurse who spends their working days inside it. A disaster threatens that familiarity and creates changes that make working in the ED during a disaster response different from the everyday experience of working in the ED. This research reports on an aspect of the findings from a larger study about the experience of working as a nurse in the ED during a disaster response. Thirteen nurses from 8 different countries were interviewed about their experience. The findings from this research demonstrate that a disaster event leads to a chain reaction of changes in process, space and practice. Nurses' respond to the news of a disaster event with shock and disbelief. The ED may change as a result of the event requiring nurses to work in an altered environment or a completely different setting. These changes provoke nurses to alter their behaviour and practice and reflect on the experience after the response. Emergency nurses have a high likelihood of participating in disaster response and as such should be adequately prepared. This highlights how disaster response is different and leads to recommendations to enhance training for emergency nurses which will better prepare them Disasterresponse is not normal business ramped up. There are a number of challenges and changes that should be considered when preparing emergency nurses for the realities of disaster response. Copyright © 2017 College of Emergency Nursing Australasia. All rights reserved.

  13. 77 FR 25658 - Negotiated Rulemaking Committee; Public Hearings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-01

    ...://www2.ed.gov/policy/highered/reg/hearulemaking/2012/index.html or contact: Wendy Macias, U.S. Department... select, from the nominees, individual negotiators who reflect the diversity among program participants.../reg/retrospective-analysis/index.html ). The Department's plan creates a defined policy, method, and...

  14. Diffuse reflectance spectroscopy for optical nerve identification. Preliminary ex vivo results for feedback controlled oral and maxillofacial laser surgery

    NASA Astrophysics Data System (ADS)

    Stelzle, Florian; Zam, Azhar; Adler, Werner; Douplik, Alexandre; Tangermann-Gerk, Katja; Nkenke, Emeka; Neukam, Friedrich Wilhelm; Schmidt, Michael

    Objective: Laser surgery has many advantages. However, due to a lack of haptic feedback it is accompanied by the risk of iatrogenic nerve damage. The aim of this study was to evaluate the possibilities of optical nerve identification by diffuse reflectance spectroscopy to set the base for a feedback control system to enhance nerve preservation in oral and maxillofacial laser surgery. Materials and Methods: Diffuse reflectance spectra of nerve tissue, skin, mucosa, fat tissue, muscle, cartilage and bone (15120 spectra) of ex vivo pig heads were acquired in the wavelength range of 350-650 nm. Tissue differentiation was performed by principal components analysis (PCA) followed by linear discriminant analysis (LDA). Specificity and sensitivity were calculated by receiver operating characteristic (ROC) analysis and the area under curve (AUC). Results: Nerve tissue could correctly be identified and differed from skin, mucosa, fat tissue, muscle, cartilage and bone in more than 90% of the cases (AUC results) with a specificity of over 78% and a sensitivity of more than 86%. Conclusion: Nerve tissue can be identified by diffuse reflectance spectroscopy with high precision and reliability. The results may set the base for a feedback system to prevent iatrogenic nerve damage performing oral and maxillofacial laser surgery.

  15. Probe pressure effects on human skin diffuse reflectance and fluorescence spectroscopy measurements

    PubMed Central

    Lim, Liang; Nichols, Brandon; Rajaram, Narasimhan; Tunnell, James W.

    2011-01-01

    Diffuse reflectance and fluorescence spectroscopy are popular research techniques for noninvasive disease diagnostics. Most systems include an optical fiber probe that transmits and collects optical spectra in contact with the suspected lesion. The purpose of this study is to investigate probe pressure effects on human skin spectroscopic measurements. We conduct an in-vivo experiment on human skin tissue to study the short-term (<2 s) and long-term (>30 s) effects of probe pressure on diffuse reflectance and fluorescence measurements. Short-term light probe pressure (P0 < 9 mN∕mm2) effects are within 0 ± 10% on all physiological properties extracted from diffuse reflectance and fluorescence measurements, and less than 0 ± 5% for diagnostically significant physiological properties. Absorption decreases with site-specific variations due to blood being compressed out of the sampled volume. Reduced scattering coefficient variation is site specific. Intrinsic fluorescence shows a large standard error, although no specific pressure-related trend is observed. Differences in tissue structure and morphology contribute to site-specific probe pressure effects. Therefore, the effects of pressure can be minimized when the pressure is small and applied for a short amount of time; however, long-term and large pressures induce significant distortions in measured spectra. PMID:21280899

  16. On the renormalisation of the diffusion asymptotics in the problem of reflection of a narrow optical beam from a biological medium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Appanov, A Yu; Barabanenkov, Yu N

    2005-12-31

    An analytic hybrid method is considered for solving the stationary radiation transfer equation in the problem on reflection of a narrow laser beam from biological media such as the 2% aqueous solution of intralipid and erythrocyte suspension with the volume concentration (hematocrit) H=0.41. The method is based on the reciprocity of the Green function in the radiation transfer theory and on the iteration solution of the integral equation for this function. As a result, the ray intensity is represented as a sum of two terms. The first of them describes the contribution of finite-order scattering to the intensity of amore » beam diffusely reflected from the medium. The second term contains the explicit analytic expression for a spatially distributed effective source of diffuse radiation emerging from the deep layers of the medium to the surface. This approach substantially improves the diffusion approximation for the problem under study and allows one to obtain the uniform asymptotics of the reflection coefficient at the specified interval of distances between the radiation source and detector on the medium surface with the relative error within {+-}6% for the 2% intralipid emulsion and erythrocyte suspension (H=0.41). (radiation scattering)« less

  17. Optical Reflectance Measurements for Commonly Used Reflectors

    NASA Astrophysics Data System (ADS)

    Janecek, Martin; Moses, William W.

    2008-08-01

    When simulating light collection in scintillators, modeling the angular distribution of optical light reflectance from surfaces is very important. Since light reflectance is poorly understood, either purely specular or purely diffuse reflectance is generally assumed. In this paper we measure the optical reflectance distribution for eleven commonly used reflectors. A 440 nm, output power stabilized, un-polarized laser is shone onto a reflector at a fixed angle of incidence. The reflected light's angular distribution is measured by an array of silicon photodiodes. The photodiodes are movable to cover 2pi of solid angle. The light-induced current is, through a multiplexer, read out with a digital multimeter. A LabVIEW program controls the motion of the laser and the photodiode array, the multiplexer, and the data collection. The laser can be positioned at any angle with a position accuracy of 10 arc minutes. Each photodiode subtends 6.3deg, and the photodiode array can be positioned at any angle with up to 10 arc minute angular resolution. The dynamic range for the current measurements is 10 5:1. The measured light reflectance distribution was measured to be specular for several ESR films as well as for aluminum foil, mostly diffuse for polytetrafluoroethylene (PTFE) tape and titanium dioxide paint, and neither specular nor diffuse for Lumirrorreg, Melinexreg and Tyvekreg. Instead, a more complicated light distribution was measured for these three materials.

  18. Specular, diffuse and polarized imagery of an oat canopy

    NASA Technical Reports Server (NTRS)

    Vanderbilt, Vern C.; De Venecia, Kurt J.

    1988-01-01

    Light, polarized by specular reflection, has been found to be an important part of the light scattered by several measured plant canopies. The authors investigate for one canopy the relative importance of specularly reflected sunlight, specularly reflected light from other sources including skylight, and diffusely upwelling light. Polarization images are used to gain increased understanding of the radiation transfer process in a plant canopy. Analysis of the results suggests that properly analyzed polarized remotely sensed data, acquired under specific atmospheric conditions by a specially designed sensor, potentially provide measures of physiological and morphological states of plants in a canopy.

  19. Neutron Reflectivity Measurement for Polymer Dynamics near Graphene Oxide Monolayers

    NASA Astrophysics Data System (ADS)

    Koo, Jaseung

    We investigated the diffusion dynamics of polymer chains confined between graphene oxide layers using neutron reflectivity (NR). The bilayers of polymethylmetacrylate (PMMA)/ deuterated PMMA (d-PMMA) films and polystyrene (PS)/d-PS films with various film thickness sandwiched between Langmuir-Blodgett (LB) monolayers of graphene oxide (GO) were prepared. From the NR results, we found that PMMA diffusion dynamics was reduced near the GO surface while the PS diffusion was not significantly changed. This is due to the different strength of GO-polymer interaction. In this talk, these diffusion results will be compared with dewetting dynamics of polymer thin films on the GO monolayers. This has given us the basis for development of graphene-based nanoelectronics with high efficiency, such as heterojunction devices for polymer photovoltaic (OPV) applications.

  20. Exploring the effect of diffuse reflection on indoor localization systems based on RSSI-VLC.

    PubMed

    Mohammed, Nazmi A; Elkarim, Mohammed Abd

    2015-08-10

    This work explores and evaluates the effect of diffuse light reflection on the accuracy of indoor localization systems based on visible light communication (VLC) in a high reflectivity environment using a received signal strength indication (RSSI) technique. The effect of the essential receiver (Rx) and transmitter (Tx) parameters on the localization error with different transmitted LED power and wall reflectivity factors is investigated at the worst Rx coordinates for a directed/overall link. Since this work assumes harsh operating conditions (i.e., a multipath model, high reflectivity surfaces, worst Rx position), an error of ≥ 1.46 m is found. To achieve a localization error in the range of 30 cm under these conditions with moderate LED power (i.e., P = 0.45 W), low reflectivity walls (i.e., ρ = 0.1) should be used, which would enable a localization error of approximately 7 mm at the room's center.

  1. Specular Reflection and Diffuse Reflectance Spectroscopy of Soils

    USDA-ARS?s Scientific Manuscript database

    Studies on the occurrence and effects of specular reflection in mid-infrared spectra of soils have shown that distortions due to specular reflection occur for both organic (humic acid) and non-organic fractions (carbonates, silica, ashed fraction of soil). The results demonstrated explain why the s...

  2. Acoustic radiosity for computation of sound fields in diffuse environments

    NASA Astrophysics Data System (ADS)

    Muehleisen, Ralph T.; Beamer, C. Walter

    2002-05-01

    The use of image and ray tracing methods (and variations thereof) for the computation of sound fields in rooms is relatively well developed. In their regime of validity, both methods work well for prediction in rooms with small amounts of diffraction and mostly specular reflection at the walls. While extensions to the method to include diffuse reflections and diffraction have been made, they are limited at best. In the fields of illumination and computer graphics the ray tracing and image methods are joined by another method called luminous radiative transfer or radiosity. In radiosity, an energy balance between surfaces is computed assuming diffuse reflection at the reflective surfaces. Because the interaction between surfaces is constant, much of the computation required for sound field prediction with multiple or moving source and receiver positions can be reduced. In acoustics the radiosity method has had little attention because of the problems of diffraction and specular reflection. The utility of radiosity in acoustics and an approach to a useful development of the method for acoustics will be presented. The method looks especially useful for sound level prediction in industrial and office environments. [Work supported by NSF.

  3. Re-evaluation of model-based light-scattering spectroscopy for tissue spectroscopy

    PubMed Central

    Lau, Condon; Šćepanović, Obrad; Mirkovic, Jelena; McGee, Sasha; Yu, Chung-Chieh; Fulghum, Stephen; Wallace, Michael; Tunnell, James; Bechtel, Kate; Feld, Michael

    2009-01-01

    Model-based light scattering spectroscopy (LSS) seemed a promising technique for in-vivo diagnosis of dysplasia in multiple organs. In the studies, the residual spectrum, the difference between the observed and modeled diffuse reflectance spectra, was attributed to single elastic light scattering from epithelial nuclei, and diagnostic information due to nuclear changes was extracted from it. We show that this picture is incorrect. The actual single scattering signal arising from epithelial nuclei is much smaller than the previously computed residual spectrum, and does not have the wavelength dependence characteristic of Mie scattering. Rather, the residual spectrum largely arises from assuming a uniform hemoglobin distribution. In fact, hemoglobin is packaged in blood vessels, which alters the reflectance. When we include vessel packaging, which accounts for an inhomogeneous hemoglobin distribution, in the diffuse reflectance model, the reflectance is modeled more accurately, greatly reducing the amplitude of the residual spectrum. These findings are verified via numerical estimates based on light propagation and Mie theory, tissue phantom experiments, and analysis of published data measured from Barrett’s esophagus. In future studies, vessel packaging should be included in the model of diffuse reflectance and use of model-based LSS should be discontinued. PMID:19405760

  4. Characterization of MODIS and SeaWiFS Solar Diffuser On-Orbit Degradation

    NASA Technical Reports Server (NTRS)

    Xiong, X.; Eplee, R. E., Jr.; Sun, J.; Patt, F. S.; Angal, A.; McClain, C. R.

    2009-01-01

    MODIS has 20 reflective solar bands (RSB), covering the VIS, NIR, and SWIR spectral regions. They are calibrated on-orbit using a solar diffuser (SD) panel, made of space-grade Spectralon. The SD bi-directional reflectance factor (BRF) was characterized pre-launch by the instrument vendor reference to the NIST reflectance standard. Its on-orbit degradation is tracked by an on-board solar diffuser stability monitor (SDSM). The SeaWifS on-orbit calibration strategy uses monthly lunar observations to monitor the long-term radiometric stability of the instrument and applies daily observations of its solar diffuser (an aluminum plate coated with YB71 paint) to track the short-term changes in the instrument response. This paper provides an overview of MODIS and SeaWiFS SD observations, applications, and approaches used to track their on-orbit degradations. Results from sensors are presented with emphasis on the spectral dependence and temporal trends of the SD degradation. Lessons and challenges from the use of SD for sensor on-orbit calibration are also discussed.

  5. Influence of earlobe thickness on near infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Jiang, Jingying; Wang, Tianpei; Li, Si; Li, Lin; Liu, Jiajia; Xu, Kexin

    2017-03-01

    Near-infrared spectroscopy has been recognized as a potential technology for noninvasive blood glucose sensing. However, the detected spectral signal is unstable mainly because of (1) the weak light absorption of glucose itself within NIR range, (2) the influence of temperature and individual differences of biotissue. Our previous results demonstrated that the synergistic effect of both transmittance and reflectance could enhance the strength of the detection signal. In this talk, we design a set of experiments to analyze the effect of earlobe thickness on Near Infrared spectroscopic measurement by using home-made optical fiber probe within the wavelength of 1000-1600nm. Firstly, we made a MC simulation of single-layer skin model and five-layer skin model to get the diffused transmittance spectra and diffused reflectance spectra under different optaical path lengths. And then we obtain the spectra of the earlobes from different volunteers by the same way. The experimental results showed that with the increase of the thickness,the light intensity of diffused transmittance decreases, and the light intensity of diffused reflectance remaines substantially unchanged.

  6. DIFFUSION OF MAGNESIUM AND MICROSTRUCTURES IN Mg+ IMPLANTED SILICON CARBIDE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Weilin; Edwards, Danny J.; Jung, Hee Joon

    2014-08-28

    Following our previous reports [ 1- 3], further isochronal annealing (2 hrs.) of the monocrystalline 6H-SiC and polycrystalline CVD 3C-SiC was performed at 1573 and 1673 K in Ar environment. SIMS data indicate that observable Mg diffusion in 6H-SiC starts and a more rapid diffusion in CVD 3C-SiC occurs at 1573 K. The implanted Mg atoms tend to diffuse deeper into the undamaged CVD 3C-SiC. The microstructure with Mg inclusions in the as-implanted SiC has been initially examined using high-resolution STEM. The presence of Mg in the TEM specimen has been confirmed based on EDS mapping. Additional monocrystalline 3C-SiC samplesmore » have been implanted at 673 K to ion fluence 3 times higher than the previous one. RBS/C analysis has been performed before and after thermal annealing at 1573 K for 12 hrs. Isothermal annealing at 1573 K is being carried out and Mg depth profiles being measured. Microstructures in both the as-implanted and annealed samples are also being examined using STEM.« less

  7. Infrared Heat Lamps used in Drying Chemical Samples, September-October 1974

    DTIC Science & Technology

    1974-10-01

    reflected from the planchette exceeds current recommended limits. DD F2MM73 1473 ED’Tt0" OF ’MOV •*IS o"SOLETE UNCLASSIFIED SECÜmTY CLASSIFICATION OF... planchette exceeds current recommended limits. Recommendations include reducing reflected luminance from the sample planchette and placing a warning...Samples, Sep-Oct 74 Figure 1. Nuclear Associates Sample Dryer Showing Metal Planchettes and Heat Lamp at Top of Page •■;’^’""- ■■ ■ ■ *wmzm

  8. Leadership for Nursing Work-Based Mobile Learning

    ERIC Educational Resources Information Center

    Fahlman, Dorothy

    2016-01-01

    This paper reflects on work-based mobile learning in the Canadian healthcare system for registered nurses' ongoing skills development and continuing professional development. It calls on distributed leadership to address the organizational contextual factors for making this mode of learning sustainable. [For the full proceedings, see ED571335.

  9. Electrochemical Study of Cobalt in Urea and Choline Chloride

    NASA Astrophysics Data System (ADS)

    Li, Min; Shi, Zhongning; Wang, Zhaowen; Reddy, Ramana G.

    The nucleation mechanism of Co(II) in urea-choline chloride-CoCl2 melt at 373 K was studied using chronoamperometry. Chronoamperometry experiments confirm that the electrodeposition of cobalt on tungsten electrode is governed by three-dimensional (3D) progressive nucleation and diffusion-controlled growth mechanisms. The average diffusion coefficient of Co(II) in the melt at 373 K is 1.1 × 10-6 cm2 s-1, which is in good agreement with the estimated value obtained from cyclic voltammetry data. Characterization of the Co electrodeposit using scanning electron microscope (SEM), energy-dispersive spectroscopy (EDS), and X-ray diffraction (XRD) techniques indicate that the electrodeposit obtained at -0.75 V and 373 K contain dense and compact surface formed from pure cobalt metal.

  10. Dynamics of controllably induced bruises assessed by diffuse reflectance spectroscopy and pulsed photothermal radiometry

    NASA Astrophysics Data System (ADS)

    Marin, Ana; Milanič, Matija; Verdel, Nina; Vidovič, Luka; Majaron, Boris

    2018-02-01

    Combination of diffuse reflectance spectroscopy (DRS) and pulsed photothermal radiometry (PPTR) was recently successfully used to study evolution of accidental traumatic bruises. Yet, accidental bruises introduce many unknowns into the evolution analysis and thus a more controllable and repeatable approach for bruising is desired. In this study, evolution of bruises induced by aluminum projectiles of known mass and velocity were studied by DRS and PPTR. Bruises were induced on volar forearm skin of two healthy volunteers. Inverse Monte Carlo including four-layer skin model, was used to analyze the DRS and PPTR data to determine skin chromophores, their concentrations and depths. For bruise analysis, a bruise model was constructed and evolved according to hemoglobin diffusion kinetics. Bruise analysis of PPTR signals yielded bruise evolution parameters, most importantly hemoglobin diffusion constant, hemoglobin decomposition time and blood pool depth. The study results show that chronological tracking of hemoglobin decomposition can be assessed by the combined DRS and PPTR technique on induced bruise. Parameters of individual bruises were compared and two trends in chronological behavior of hemoglobin decomposition time discerned. Changes in bruise diffuse reflectance spectra were noted. Induced bruise parameters, however, still showed some scatter and thus further research is needed to reduce bruise variability.

  11. Non-destructive Techniques for Classifying Aircraft Coating Degradation

    DTIC Science & Technology

    2015-03-26

    model is bidirectional reflectance distribution func- tions ( BRDF ) which describes how much radiation is reflected for each solid angle and each...incident angle. An intermediate model between ideal reflectors and BRDF is to assume all reflectance is a combination of diffuse and specular reflectance...19 K-Fold Cross Validation

  12. [Achievement of the noninvasive measurement for human blood glucose with NIR diffusion reflectance spectrum method].

    PubMed

    Zhang, Hong-yan; Ding, Dong; Song, Li-qiang; Gu, Lin-na; Yang, Peng; Tang, Yu-guo

    2005-06-01

    The noninvasive measurement of human blood glucose was achieved with NIR diffusion reflectance spectrum method. The thumb fingertip NIR diffusion reflectance spectra of six different age healthy volunteers were collected using Nexus-870 and its NIR fiber port smart accessory. The test was implemented with changing the blood glucose concentration for the limosis and satiation of every volunteer. The calibration model was set up using PLS method with the smoothing, baseline correction and first derivatives pretreatment spectrum in the 7500-8500 cm(-1) region for single volunteer, the same age combination and that of different age. When the spectrum was obtained, the actual blood glucose value of every spectrun sample was demarcated using ultraviolet spectrophotometer. The correlation between the calibration value and true value for single volunteer is better than that for the combination of volunteers, the correlative coefficients are all over 0.90471, RMSECs are all less than 0.171.

  13. PRELIMINARY RESULTS OF BTDF CALIBRATION OF TRANSMISSIVE SOLAR DIFFUSERS FOR REMOTE SENSING.

    PubMed

    Georgiev, Georgi T; Butler, James J; Thome, Kurt; Cooksey, Catherine; Ding, Leibo

    2016-01-01

    Satellite instruments operating in the reflected solar wavelength region require accurate and precise determination of the optical properties of their diffusers used in pre-flight and post-flight calibrations. The majority of recent and current space instruments use reflective diffusers. As a result, numerous Bidirectional Reflectance Distribution Function (BRDF) calibration comparisons have been conducted between the National Institute of Standards and Technology (NIST) and other industry and university-based metrology laboratories. However, based on literature searches and communications with NIST and other laboratories, no Bidirectional Transmittance Distribution Function (BTDF) measurement comparisons have been conducted between National Measurement Laboratories (NMLs) and other metrology laboratories. On the other hand, there is a growing interest in the use of transmissive diffusers in the calibration of satellite, air-borne, and ground-based remote sensing instruments. Current remote sensing instruments employing transmissive diffusers include the Ozone Mapping and Profiler Suite instrument (OMPS) Limb instrument on the Suomi-National Polar-orbiting Partnership (S-NPP) platform,, the Geostationary Ocean Color Imager (GOCI) on the Korea Aerospace Research Institute's (KARI) Communication, Ocean, and Meteorological Satellite (COMS), the Ozone Monitoring Instrument (OMI) on NASA's Earth Observing System (EOS) Aura platform, the Tropospheric Emissions: Monitoring of Pollution (TEMPO) instrument and the Geostationary Environmental Monitoring Spectrometer (GEMS).. This ensemble of instruments requires validated BTDF measurements of their on-board transmissive diffusers from the ultraviolet through the near infrared. This paper presents the preliminary results of a BTDF comparison between the NASA Diffuser Calibration Laboratory (DCL) and NIST on quartz and thin Spectralon samples.

  14. Preliminary Results of BTDF Calibration of Transmissive Solar Diffusers for Remote Sensing

    NASA Technical Reports Server (NTRS)

    Georgiev, Georgi T.; Butler, James J.; Thome, Kurt; Cooksey, Catherine; Ding, Leibo

    2016-01-01

    Satellite instruments operating in the reflected solar wavelength region require accurate and precise determination of the optical properties of their diffusers used in pre-flight and post-flight calibrations. The majority of recent and current space instruments use reflective diffusers. As a result, numerous Bidirectional Reflectance Distribution Function (BRDF) calibration comparisons have been conducted between the National Institute of Standards and Technology (NIST) and other industry and university-based metrology laboratories. However, based on literature searches and communications with NIST and other laboratories, no Bidirectional Transmittance Distribution Function (BTDF) measurement comparisons have been conducted between National Measurement Laboratories (NMLs) and other metrology laboratories. On the other hand, there is a growing interest in the use of transmissive diffusers in the calibration of satellite, air-borne, and ground-based remote sensing instruments. Current remote sensing instruments employing transmissive diffusers include the Ozone Mapping and Profiler Suite instrument (OMPS) Limb instrument on the Suomi-National Polar-orbiting Partnership (S-NPP) platform,, the Geostationary Ocean Color Imager (GOCI) on the Korea Aerospace Research Institute's (KARI) Communication, Ocean, and Meteorological Satellite (COMS), the Ozone Monitoring Instrument (OMI) on NASA's Earth Observing System (EOS) Aura platform, the Tropospheric Emissions: Monitoring of Pollution (TEMPO) instrument and the Geostationary Environmental Monitoring Spectrometer (GEMS).. This ensemble of instruments requires validated BTDF measurements of their on-board transmissive diffusers from the ultraviolet through the near infrared. This paper presents the preliminary results of a BTDF comparison between the NASA Diffuser Calibration Laboratory (DCL) and NIST on quartz and thin Spectralon samples.

  15. PRELIMINARY RESULTS OF BTDF CALIBRATION OF TRANSMISSIVE SOLAR DIFFUSERS FOR REMOTE SENSING

    PubMed Central

    Georgiev, Georgi T.; Butler, James J.; Thome, Kurt; Cooksey, Catherine; Ding, Leibo

    2016-01-01

    Satellite instruments operating in the reflected solar wavelength region require accurate and precise determination of the optical properties of their diffusers used in pre-flight and post-flight calibrations. The majority of recent and current space instruments use reflective diffusers. As a result, numerous Bidirectional Reflectance Distribution Function (BRDF) calibration comparisons have been conducted between the National Institute of Standards and Technology (NIST) and other industry and university-based metrology laboratories. However, based on literature searches and communications with NIST and other laboratories, no Bidirectional Transmittance Distribution Function (BTDF) measurement comparisons have been conducted between National Measurement Laboratories (NMLs) and other metrology laboratories. On the other hand, there is a growing interest in the use of transmissive diffusers in the calibration of satellite, air-borne, and ground-based remote sensing instruments. Current remote sensing instruments employing transmissive diffusers include the Ozone Mapping and Profiler Suite instrument (OMPS) Limb instrument on the Suomi-National Polar-orbiting Partnership (S-NPP) platform,, the Geostationary Ocean Color Imager (GOCI) on the Korea Aerospace Research Institute’s (KARI) Communication, Ocean, and Meteorological Satellite (COMS), the Ozone Monitoring Instrument (OMI) on NASA’s Earth Observing System (EOS) Aura platform, the Tropospheric Emissions: Monitoring of Pollution (TEMPO) instrument and the Geostationary Environmental Monitoring Spectrometer (GEMS).. This ensemble of instruments requires validated BTDF measurements of their on-board transmissive diffusers from the ultraviolet through the near infrared. This paper presents the preliminary results of a BTDF comparison between the NASA Diffuser Calibration Laboratory (DCL) and NIST on quartz and thin Spectralon samples. PMID:28003712

  16. Highly reflective Ag-Cu alloy-based ohmic contact on p-type GaN using Ru overlayer.

    PubMed

    Son, Jun Ho; Jung, Gwan Ho; Lee, Jong-Lam

    2008-12-15

    We report on a metallization scheme of high reflectance, low resistance, and smooth surface morphology ohmic contact on p-type GaN. Ag-Cu alloy/Ru contact showed low contact resistivity as low as 6.2 x 10(-6) Ohms cm(2) and high reflectance of 91% at 460 nm after annealing at 400 degrees C in air ambient. The oxidation annealing promoted the out-diffusion of Ga atoms to dissolve in an Ag-Cu layer with the formation of an Ag-Ga solid solution, lowering the contact resistivity. The Ru overlayer acts as a diffusion barrier for excessive oxygen incorporation during oxidation annealing, resulting in high reflectance, good thermal stability, and smooth surface quality of the contact.

  17. On the Symmetry of Molecular Flows Through the Pipe of an Arbitrary Shape (I) Diffusive Reflection

    NASA Astrophysics Data System (ADS)

    Kusumoto, Yoshiro

    Molecular gas flows through the pipe of an arbitrary shape is mathematically considered based on a diffusive reflection model. To avoid a perpetual motion, the magnitude of the molecular flow rate must remain invariant under the exchange of inlet and outlet pressures. For this flow symmetry, the cosine law reflection at the pipe wall was found to be sufficient and necessary, on the assumption that the molecular flux is conserved in a collision with the wall. It was also shown that a spontaneous flow occurs in a hemispherical apparatus, if the reflection obeys the n-th power of cosine law with n other than unity. This apparatus could work as a molecular pump with no moving parts.

  18. Discrete ordinates solutions of nongray radiative transfer with diffusely reflecting walls

    NASA Technical Reports Server (NTRS)

    Menart, J. A.; Lee, Haeok S.; Kim, Tae-Kuk

    1993-01-01

    Nongray gas radiation in a plane parallel slab bounded by gray, diffusely reflecting walls is studied using the discrete ordinates method. The spectral equation of transfer is averaged over a narrow wavenumber interval preserving the spectral correlation effect. The governing equations are derived by considering the history of multiple reflections between two reflecting wails. A closure approximation is applied so that only a finite number of reflections have to be explicitly included. The closure solutions express the physics of the problem to a very high degree and show relatively little error. Numerical solutions are obtained by applying a statistical narrow-band model for gas properties and a discrete ordinates code. The net radiative wail heat fluxes and the radiative source distributions are obtained for different temperature profiles. A zeroth-degree formulation, where no wall reflection is handled explicitly, is sufficient to predict the radiative transfer accurately for most cases considered, when compared with increasingly accurate solutions based on explicitly tracing a larger number of wail reflections without any closure approximation applied.

  19. Generalized thermoelastic diffusive waves in heat conducting materials

    NASA Astrophysics Data System (ADS)

    Sharma, J. N.

    2007-04-01

    Keeping in view the applications of diffusion processes in geophysics and electronics industry, the aim of the present paper is to give a detail account of the plane harmonic generalized thermoelastic diffusive waves in heat conducting solids. According to the characteristic equation, three longitudinal waves namely, elastodiffusive (ED), mass diffusion (MD-mode) and thermodiffusive (TD-mode), can propagate in such solids in addition to transverse waves. The transverse waves get decoupled from rest of the fields and hence remain unaffected due to temperature change and mass diffusion effects. These waves travel without attenuation and dispersion. The other generalized thermoelastic diffusive waves are significantly influenced by the interacting fields and hence suffer both attenuation and dispersion. At low frequency mass diffusion and thermal waves do not exist but at high-frequency limits these waves propagate with infinite velocity being diffusive in character. Moreover, in the low-frequency regions, the disturbance is mainly dominant by mechanical process of transportation of energy and at high-frequency regions it is significantly dominated by a close to diffusive process (heat conduction or mass diffusion). Therefore, at low-frequency limits the waves like modes are identifiable with small amplitude waves in elastic materials that do not conduct heat. The general complex characteristic equation is solved by using irreducible case of Cardano's method with the help of DeMoivre's theorem in order to obtain phase speeds, attenuation coefficients and specific loss factor of energy dissipation of various modes. The propagation of waves in case of non-heat conducting solids is also discussed. Finally, the numerical solution is carried out for copper (solvent) and zinc (solute) materials and the obtained phase velocities, attenuation coefficients and specific loss factor of various thermoelastic diffusive waves are presented graphically.

  20. Mixing and diffusion in intermittent overturning turbulence

    NASA Astrophysics Data System (ADS)

    Redondo, Jose M.; Mahjoub, Otman B.; Gonzalez-Nieto, Pilar L.; Lawry, Andrew

    2014-05-01

    The improvements in experimental methods and high resolution image analysis are nowadays able to detect subtle changes in the structure of the turbulence over a wide range of temporal and spatial scales [1], we compare the scaling shown by different mixing fronts driven by buoyancy that form a Rayleigh-Taylor mixing front. We use PIV and density front tracking in several experimental configurations akin to geophysical overturning [2-7]. We parametrize the role of unstable stratification by means of the Atwood number and compare both the scaling and the multifractal and the maximum local fractal structure functions of the different markers used to visualize the front. Both reactive and passive scalar tracers are used to investigate the mixing structure and the intermittency of the flow. Different initial conditions are compared and the mixing efficiency of the overal turbulent process evaluated [6-7]. An interesting approach, relating the Multi-Fractal dimension spectra, the intermittency and the spectral exponent is to find relationships that may be used to parameterise the sub-grid turbulence in terms of generalized diffusivities [4 ] that take into account the topology and the self-similarity of the Mixing RT and RM flows. As an example, a relationship between the diffusivity, the exponent β, the intermittency μ, and D(i), may be found for the volume fraction or the concentration, at the same time other locally measured parameters such as the enstrophy or the gradient alignment as well as their multi-fractal structures may turn out to be physically relevant indicators of the local turbulence and the mixing. Several methods of deriving local eddy diffusivity and local entrainment should give more realistic estimates of the spatial/temporal non-homogeneities (and intermittencies in the Kolmogorov 62 sense obtained as spatial correlations of the turbulent dissipation, or from structure functions) and these values may be used to parameterise turbulence at a variety of scales. The method involving the multi-fractal dimension measurements is much more elaborated and seems to have a better theoretical justification in the sense that it is possible that different concentrations showing different fractal dimensions may be due to different levels of intermittency (and thus different spectra, which are not generally in equilibrium as dscribed by[9,10]. Using topological descriptors we can establish now a theoretical baseline pattern for the turbulence behaviour that is reflected in the different structures (volume fraction, velocity, vorticity, helicity) we can thus obtain a classification relating D3 and the integral of the different fractal dimensions D2 for different levels of scalar (volume fraction reaction intensity or temperature). [5,8,11] Vorticity evolution is more smooth and quite different than that of volume fraction or density and these seem also different for the RT and RM instability driven mixing showing a wider range of even higher mixing efficiencies 0- 0.66 Thanks to European Union project ERBIC15-CT96-0111 Multi-scale complex fluid flows and interfacial phenomena (PITN-GA-2008-214919). ERCOFTAC and GenCat. grant 2001SGR00221. [1] Mahjoub O.B., Redondo J.M. and Babiano A. (2000) Hyerarchy flux in nonhomogeneous flows in Turbulent diffusion in the environment Eds. Redondo J.M. and Babiano A. 249-260. . [2] Dalziel, S. B.,(1994) Perturbations and coherent flow in Rayleigh-Taylor instability: in 4th International Workshop on the Physics of Compressible Turbulent Mixing, ed. P. F. Linden, D. L. Youngs, & S. B. Dalziel; 32-41. [3] Linden, P. F., Redondo, J. M., and Youngs, D. (1994) Molecular mixing in Rayleigh-Taylor instability, J. Fluid Mech. 265, 97-124 [4] Vindel, J.M., Yague, C. and Redondo, J.M. Nuovo Cimento (2008) 31, [5]Redondo J.M. (1993) Fractal models of density interfaces. Wavelets, Fractals and Fourier transforms. (Eds.) M. Farge, J.C.R. Hunt and J.C. Vassilicos. 353-370. IMA number 43, Clarendon Press, Oxford 1993 [6] J.M Redondo, J.M. Grau, A. Platonov, G. Garzon, (2008) Rev. Int. Met. Num. Ing. 24, 23. [7] Fraunie P., Berreba S. Chashechkin Y., Velasco D. and Redondo J.M. (2008) LES and laboratory experiments on the decay of grid wakes in strongly stratified flows. Il Nuovo Cimento C 31, 909-930. [8] Redondo J.M. (2002) "Mixing efficiencies of different kinds of turbulent processes and instabilities, Applications to the environment in Turbulent mixing in geophysical flows". Eds. Linden P.F. and Redondo J.M. 131-157. [9] Redondo J.M. (1990). The structure of density interfaces, Ph. D. Thesis, DAMTP University of Cambridge. [10]Redondo J.M. (1987). Effects of ground proximity on dense gas entrainment, Journal of Hazardous Materials, 16, 381-393. [11] Lopez, P., Cano, J.L. and Redondo, J.M.(2008) An experimental model of mixing processes generated by an array of top-heavy turbulent plumes, Il Nuovo Cimento, 31C, 679-698.

  1. Temperature dependence of Fe/++/ crystal field spectra - Implications to mineralogical mapping of planetary surfaces

    NASA Technical Reports Server (NTRS)

    Sung, C.-M.; Singer, R. B.; Parkin, K. M.; Burns, R. G.; Osborne, M.

    1977-01-01

    Results are reported of Fe(++) crystal field spectral measurements for olivines and pyroxenes up to 400 C. The results are correlated with crystal structure data at elevated temperatures, and the validity of remote-sensed identifications of minerals on hot surfaces of the moon and Mercury is assessed. Two techniques were used to obtain spectra of minerals at elevated temperatures using a spectrophotometer. One employed a diamond cell assembly or a specially designed sample holder to measure polarized absorption spectra of heated single crystals. For the other technique, a sample holder was designed to attach to a diffuse reflectance accessory to produce reflectance spectra of heated powdered samples. Polarized absorption spectra of forsterite at 20-400 C are shown in a graph. Other graphs show the temperature dependence of Fe(++) crystal field bands in olivines, the diffuse reflectance spectra of olivine at 40-400 C, the polarization absorption spectra of orthopyroxene at 30-400 C, the diffuse reflectance spectra of pigeonite at 40-400 C, and unpolarized absorption spectra of lunar pyroxene from Apollo 15 rock 15058.

  2. Diffuse reflectance spectroscopy for monitoring diabetic foot ulcer - A pilot study

    NASA Astrophysics Data System (ADS)

    Anand, Suresh; Sujatha, N.; Narayanamurthy, V. B.; Seshadri, V.; Poddar, Richa

    2014-02-01

    Foot ulceration due to diabetes mellitus is a major problem affecting 12-25% of diabetic subjects in their lifetime. An untreated ulcer further gets infected which causes necrosis leading to amputation of lower extremities. Early identification of risk factors and treatment for these chronic wounds would reduce health care costs and improve the quality of life for people with diabetes. Recent clinical investigations have shown that a series of factors including reduced oxygen delivery and disturbed metabolism have been observed on patients with foot ulceration due to diabetes. Also, these factors can impair the wound healing process. Optical techniques based on diffuse reflectance spectroscopy provide characteristic spectral finger prints shed light on tissue oxygenation levels and morphological composition of a tissue. This study deals with the application of diffuse reflectance intensity ratios based on oxyhemoglobin bands (R542/R580), ratios of oxy- and deoxy-hemoglobin bands (R580/R555), total hemoglobin concentration and hemoglobin oxygen saturation between normal and diabetic foot ulcer sites. Preliminary results obtained are found to be promising indicating the application of reflectance spectroscopy in the assessment of foot ulcer healing.

  3. High reflected cubic cavity as long path absorption cell for infrared gas sensing

    NASA Astrophysics Data System (ADS)

    Yu, Jia; Gao, Qiang; Zhang, Zhiguo

    2014-10-01

    One direct and efficient method to improve the sensitivity of infrared gas sensors is to increase the optical path length of gas cells according to Beer-Lambert Law. In this paper, cubic shaped cavities with high reflected inner coating as novel long path absorption cells for infrared gas sensing were developed. The effective optical path length (EOPL) for a single cubic cavity and tandem cubic cavities were investigated based on Tunable Diode Laser Absorption Spectroscopy (TDLAS) measuring oxygen P11 line at 763 nm. The law of EOPL of a diffuse cubic cavity in relation with the reflectivity of the coating, the port fraction and side length of the cavity was obtained. Experimental results manifested an increase of EOPL for tandem diffuse cubic cavities as the decrease of port fraction of the connecting aperture f', and the EOPL equaled to the sum of that of two single cubic cavities at f'<0.01. The EOPL spectra at infrared wavelength range for different inner coatings including high diffuse coatings and high reflected metallic thin film coatings were deduced.

  4. Beer-Lambert-Law Parametric Model of Reflectance Spectra for Dyed Fabrics

    DTIC Science & Technology

    2016-06-06

    optical constants), phenomenological quantities and combinations of both [27,28,29]. For reflection from a dyed fabric of finite and nonuniform ...fabrics are characterized, inherently, by rough surfaces (thus diffuse reflectance), heterogeneous compositions, and nonuniform thicknesses. It follows

  5. Management of Food-Related Diarrhea Outbreak in the Emergency Department: Lessons Learned from the German STEC O104:H4 Epidemic.

    PubMed

    Sayk, Friedhelm; Asselborn, Niels Henrik; Eisemann, Nora; Katalinic, Alexander; Metzner, Jörg; Wolfrum, Sebastian; Fellermann, Klaus; Knobloch, Johannes; Nitschke, Martin

    2015-01-01

    Emergency department (ED) management of the German STEC O104:H4 outbreak in 2011 was not limited to patients being truly infected with STEC. In parallel to spread of alarming news in public media, patients suffering from diarrhea due to other reasons fearfully presented, equally. We retrospectively characterized these two cohorts for anamnestic, clinical, and laboratory findings at their first ED contact. From 15th of May to July 2011, 302 adult patients with diarrheal complaint presented at the EDs of two tertiary hospitals in Lubeck, northern Germany. Fecal testing for STEC was obtained in 245 (81%) patients: 105 were STEC-positive and 140 were STEC-negative. Anamnestic characteristics (defecation rate, visible bloody diarrhea, and lower abdominal pain), abdominal tenderness, and some laboratory findings were significantly different between both cohorts but not reliable to exclude STEC. In >90% of STEC-positive patients diarrheal symptoms had started in May, reflecting the retrospective nationwide peak of infections, whereas the majority of STEC-negative patients became symptomatic in June 2011. During the German STEC O104:H4 outbreak a definite distinction at initial ED contact between STEC-positive versus STEC-negative patients by clinical judgment alone was not reliable. Fecal testing in the ED, however, might survey the outbreak of foodborne infections with the utmost precision.

  6. Quality of coding diagnoses in emergency departments: effects on mapping the public's health.

    PubMed

    Aharonson-Daniel, Limor; Schwartz, Dagan; Hornik-Lurie, Tzipi; Halpern, Pinchas

    2014-01-01

    Emergency department (ED) attendees reflect the health of the population served by that hospital and the availability of health care services in the community. To examine the quality and accuracy of diagnoses recorded in the ED to appraise its potential utility as a guage of the population's medical needs. Using the Delphi process, a preliminary list of health indicators generated by an expert focus group was converted to a query to the Ministry of Health's database. In parallel, medical charts were reviewed in four hospitals to compare the handwritten diagnosis in the medical record with that recorded on the standard diagnosis "pick list" coding sheet. Quantity and quality of coding were assessed using explicit criteria. During 2010 a total of 17,761 charts were reviewed; diagnoses were not coded in 42%. The accuracy of existing coding was excellent (mismatch 1%-5%). Database query (2,670,300 visits to 28 hospitals in 2009) demonstrated potential benefits of these data as indicators of regional health needs. The findings suggest that an increase in the provision of community care may reduce ED attendance. Information on ED visits can be used to support health care planning. A "pick list" form with common diagnoses can facilitate quality recording of diagnoses in a busy ED, profiling the population's health needs in order to optimize care. Better compliance with the directive to code diagnosis is desired.

  7. Transient Shifts of Incubation Temperature Reveal Immediate and Long-Term Transcriptional Response in Chicken Breast Muscle Underpinning Resilience and Phenotypic Plasticity.

    PubMed

    Naraballobh, Watcharapong; Trakooljul, Nares; Murani, Eduard; Brunner, Ronald; Krischek, Carsten; Janisch, Sabine; Wicke, Michael; Ponsuksili, Siriluck; Wimmers, Klaus

    2016-01-01

    Variations in egg incubation temperatures can have acute or long-term effects on gene transcription in avian species. Altered gene expression may, in turn, affect muscle traits in poultry and indirectly influence commercial production. To determine how changes in eggshell temperature affect gene expression, incubation temperatures were varied [36.8°C (low), 37.8°C (control), 38.8°C (high)] at specific time periods reflecting two stages of myogenesis [embryonic days (ED) 7-10 and 10-13]. Gene expression was compared between interventions and matching controls by microarrays in broiler breast muscle at ED10 or ED13 and post-hatch at day 35. Early (ED7-10) high incubation temperature (H10ΔC) resulted in 1370 differentially expressed genes (DEGs) in embryos. Ingenuity pathway analysis revealed temporary activation of cell maintenance, organismal development, and survival ability genes, but these effects were not maintained in adults. Late high incubation temperature (ED10-13) (H13ΔC) had slightly negative impacts on development of cellular components in embryos, but a cumulative effect was observed in adults, in which tissue development and nutrition metabolism were affected. Early low incubation temperature (L10ΔC) produced 368 DEGs, most of which were down-regulated and involved in differentiation and formation of muscle cells. In adults, this treatment down-regulated pathways of transcriptional processes, but up-regulated cell proliferation. Late low temperature incubation (L13ΔC) produced 795 DEGs in embryos, and activated organismal survival and post-transcriptional regulation pathways. In adults this treatment activated cellular and organ development, nutrition and small molecule activity, and survival rate, but deactivated size of body and muscle cells. Thermal interventions during incubation initiate immediate and delayed transcriptional responses that are specific for timing and direction of treatment. Interestingly, the transcriptional response to transiently decreased incubation temperature, which did not affect the phenotypes, prompts compensatory effects reflecting resilience. In contrast, higher incubation temperature triggers gene expression and has long-term effects on the phenotype. These mechanisms of considerable phenotypic plasticity contribute to the biodiversity and broaden the basis for managing poultry populations.

  8. Copper Gas Diffusers For Purging Line-Focus Laser Welds

    NASA Technical Reports Server (NTRS)

    Fonteyne, Steve L.; Hosking, Timothy J.; Shelley, D. Mark

    1996-01-01

    Modified flow diffusers built for inert-gas purging of welds made with 5-kW CO(2) lasers operating with line-focus optics in conduction mode instead of with point-focus optics in customary keyhole mode. Diffusers made of copper components brazed together, robust enough to withstand strong reflections of line-focused laser energy.

  9. Does Everyone Have a Musical Identity?: Reflections on "Musical Identities"

    ERIC Educational Resources Information Center

    Gracyk, Theodore

    2004-01-01

    The book, "Musical Identities" (Raymond MacDonald, David Hargreaves, Dorothy Miell, eds.; Oxford and New York: Oxford University Press, 2002) consists of 11 essays on the psychology of music. The editors divided the essays into two groups: those on developing musical identities ("identities in music" involving recognizable…

  10. Practising Knowing: Emergence(y) Teleologies

    ERIC Educational Resources Information Center

    Manidis, Marie; Scheeres, Hermine

    2013-01-01

    This article presents a meta-disciplinary and institutional framework of practices used by nurses and doctors to manage the indeterminacy of knowing in emergency departments (EDs) in Australia. We draw on Schatzkian perspectives of how practices prevail and reflect particular site ontologies. We posit that nurses and doctors draw on a repertoire…

  11. Beyond the DSM-IV: Assumptions, Alternatives, and Alterations

    ERIC Educational Resources Information Center

    Lopez, Shane J.; Edwards, Lisa M.; Pedrotti, Jennifer Teramoto; Prosser, Ellie C.; LaRue, Stephanie; Spalitto, Susan Vehige; Ulven, Jon C.

    2006-01-01

    Current diagnostic processes reflect the limitations and utility of the framework of the "Diagnostic and Statistical Manual of Mental Disorders" (4th ed.; DSM-IV; American Psychiatric Association, 1994). Clinical information in the DSM-IV's 5-axis system almost exclusively focuses on weaknesses and pathology and is summarized in a flawed…

  12. Cultural Dysthymia: An Unrecognized Disorder among African Americans?

    ERIC Educational Resources Information Center

    Vontress, Clemmont E.; Woodland, Calvin E.; Epp, Lawrence

    2007-01-01

    Many African Americans experience low-grade depression, referred to as dysthymia in the Diagnostic and Statistical Manual of Mental Disorders (4th ed., text rev.; American Psychiatric Association, 2000). After more than 250 years of enslavement, prejudice, and discrimination, dysthymia is reflected in chronic low-grade sadness, anger, hostility,…

  13. Eating Disorder Diagnoses: Empirical Approaches to Classification

    ERIC Educational Resources Information Center

    Wonderlich, Stephen A.; Joiner, Thomas E., Jr.; Keel, Pamela K.; Williamson, Donald A.; Crosby, Ross D.

    2007-01-01

    Decisions about the classification of eating disorders have significant scientific and clinical implications. The eating disorder diagnoses in the Diagnostic and Statistical Manual of Mental Disorders (4th ed.; DSM-IV; American Psychiatric Association, 1994) reflect the collective wisdom of experts in the field but are frequently not supported in…

  14. Baseline Correction of Diffuse Reflection Near-Infrared Spectra Using Searching Region Standard Normal Variate (SRSNV).

    PubMed

    Genkawa, Takuma; Shinzawa, Hideyuki; Kato, Hideaki; Ishikawa, Daitaro; Murayama, Kodai; Komiyama, Makoto; Ozaki, Yukihiro

    2015-12-01

    An alternative baseline correction method for diffuse reflection near-infrared (NIR) spectra, searching region standard normal variate (SRSNV), was proposed. Standard normal variate (SNV) is an effective pretreatment method for baseline correction of diffuse reflection NIR spectra of powder and granular samples; however, its baseline correction performance depends on the NIR region used for SNV calculation. To search for an optimal NIR region for baseline correction using SNV, SRSNV employs moving window partial least squares regression (MWPLSR), and an optimal NIR region is identified based on the root mean square error (RMSE) of cross-validation of the partial least squares regression (PLSR) models with the first latent variable (LV). The performance of SRSNV was evaluated using diffuse reflection NIR spectra of mixture samples consisting of wheat flour and granular glucose (0-100% glucose at 5% intervals). From the obtained NIR spectra of the mixture in the 10 000-4000 cm(-1) region at 4 cm intervals (1501 spectral channels), a series of spectral windows consisting of 80 spectral channels was constructed, and then SNV spectra were calculated for each spectral window. Using these SNV spectra, a series of PLSR models with the first LV for glucose concentration was built. A plot of RMSE versus the spectral window position obtained using the PLSR models revealed that the 8680–8364 cm(-1) region was optimal for baseline correction using SNV. In the SNV spectra calculated using the 8680–8364 cm(-1) region (SRSNV spectra), a remarkable relative intensity change between a band due to wheat flour at 8500 cm(-1) and that due to glucose at 8364 cm(-1) was observed owing to successful baseline correction using SNV. A PLSR model with the first LV based on the SRSNV spectra yielded a determination coefficient (R2) of 0.999 and an RMSE of 0.70%, while a PLSR model with three LVs based on SNV spectra calculated in the full spectral region gave an R2 of 0.995 and an RMSE of 2.29%. Additional evaluation of SRSNV was carried out using diffuse reflection NIR spectra of marzipan and corn samples, and PLSR models based on SRSNV spectra showed good prediction results. These evaluation results indicate that SRSNV is effective in baseline correction of diffuse reflection NIR spectra and provides regression models with good prediction accuracy.

  15. The impact of routine cognitive screening by using the clock drawing task in the evaluation of elderly patients in the emergency department.

    PubMed

    Salen, Philip; Heller, Michael; Oller, Carlo; Reed, James

    2009-07-01

    The prevalence of cognitive impairment, as reflected by failure to correctly perform a clock drawing task, in elderly Emergency Department (ED) patients was assessed. Additionally, we evaluated whether primary care provider notification of cognitive impairment spurred further cognitive evaluation. The clock drawing task was administered to a convenience sample of 100 elderly, English-speaking subjects presenting for reasons other than altered mentation at a community hospital ED. Primary care providers were contacted regarding abnormal clock drawing task results immediately and again after 2 months to determine if there was further evaluation of cognition. Of the 100 subjects enrolled, 30% were unable to correctly complete the clock drawing task, but only 8 had further evaluation of their cognitive abilities, resulting in four new diagnoses of dementia. Subjects who drew incorrect clocks (54%; 16/30) were more likely to be reevaluated in the ED within 2 months than those who drew correct clocks (29%; 20/70; p < 0.02). Cognitive screening of elderly ED patients with the clock drawing task identified a substantial number with unsuspected abnormal cognition. Further evaluation by their primary care physicians in follow-up was disappointing.

  16. Diffuse reflection from a stochastically bounded, semi-infinite medium

    NASA Technical Reports Server (NTRS)

    Lumme, K.; Peltoniemi, J. I.; Irvine, W. M.

    1990-01-01

    In order to determine the diffuse reflection from a medium bounded by a rough surface, the problem of radiative transfer in a boundary layer characterized by a statistical distribution of heights is considered. For the case that the surface is defined by a multivariate normal probability density, the propagation probability for rays traversing the boundary layer is derived and, from that probability, a corresponding radiative transfer equation. A solution of the Eddington (two stream) type is found explicitly, and examples are given. The results should be applicable to reflection from the regoliths of solar system bodies, as well as from a rough ocean surface.

  17. Wave reflection in a reaction-diffusion system: breathing patterns and attenuation of the echo.

    PubMed

    Tsyganov, M A; Ivanitsky, G R; Zemskov, E P

    2014-05-01

    Formation and interaction of the one-dimensional excitation waves in a reaction-diffusion system with the piecewise linear reaction functions of the Tonnelier-Gerstner type are studied. We show that there exists a parameter region where the established regime of wave propagation depends on initial conditions. Wave phenomena with a complex behavior are found: (i) the reflection of waves at a growing distance (the remote reflection) upon their collision with each other or with no-flux boundaries and (ii) the periodic transformation of waves with the jumping from one regime of wave propagation to another (the periodic trigger wave).

  18. Wave reflection in a reaction-diffusion system: Breathing patterns and attenuation of the echo

    NASA Astrophysics Data System (ADS)

    Tsyganov, M. A.; Ivanitsky, G. R.; Zemskov, E. P.

    2014-05-01

    Formation and interaction of the one-dimensional excitation waves in a reaction-diffusion system with the piecewise linear reaction functions of the Tonnelier-Gerstner type are studied. We show that there exists a parameter region where the established regime of wave propagation depends on initial conditions. Wave phenomena with a complex behavior are found: (i) the reflection of waves at a growing distance (the remote reflection) upon their collision with each other or with no-flux boundaries and (ii) the periodic transformation of waves with the jumping from one regime of wave propagation to another (the periodic trigger wave).

  19. Self perceived work related stress and the relation with salivary IgA and lysozyme among emergency department nurses

    PubMed Central

    Yang, Y; Koh, D; Ng, V; Lee, C; Chan, G; Dong, F; Goh, S; Anantharaman, V; Chia, S

    2002-01-01

    Aims: To assess and compare the self perceived work related stress among emergency department (ED) and general ward (GW) nurses, and to investigate its relation with salivary IgA and lysozyme. Methods: One hundred and thirty two of 208 (63.5%) registered female ED and GW nurses participated in the study. A modified mental health professional stress scale (PSS) was used to measure self perceived stress. ELISA methods were used to determine the salivary IgA and lysozyme levels. Results: On PSS, ED nurses had higher scores (mean 1.51) than GW nurses (1.30). The scores of PSS subscales such as organisational structure and processes (OS), lack of resources (RES), and conflict with other professionals (COF) were higher in ED than in GW nurses. ED nurses had lower secretion rates of IgA (geometric mean (GM) 49.1 µg/min) and lysozyme (GM 20.0 µg/min) than GW nurses (68.2 µg/min, 30.5 µg/min). Significant correlations were observed between PSS and log IgA and lysozyme secretion rates. OS, RES, and COF were correlated with log IgA and lysozyme levels. Conclusion: ED nurses, who reported a higher level of professional stress, showed significantly lower secretion rates of salivary IgA and lysozyme compared to GW nurses. Salivary IgA and lysozyme were inversely correlated with self perceived work related stress. As these salivary biomarkers are reflective of the mucosal immunity, results support the inverse relation between stress and mucosal immunity. PMID:12468751

  20. Application of Diffuse Reflectance FT-IR Spectroscopy for the Surface Study of Kevlar Fibers

    NASA Astrophysics Data System (ADS)

    Chatzi, E. G.; Ishida, H.; Koenig, J. L.

    1985-12-01

    The surfaces of Kevlar-49 aramid fibers, being used in high-performance composite materials, have been characterized by diffuse reflectance Fourier transform infrared (FT-IR) spectroscopy. Enhancement of the surface selectivity of the technique has been achieved using KBr overlayers. The water absorbed by both the skin and the core of the fibers has been characterized by using this technique and the accessibility of the fiber functional groups has been evaluated.

  1. Influence of low power CW laser irradiation on skin hemoglobin changes

    NASA Astrophysics Data System (ADS)

    Ferulova, Inesa; Lesins, Janis; Lihachev, Alexey; Jakovels, Dainis; Spigulis, Janis

    2012-06-01

    Influence of low power laser irradiance on healthy skin using diffuse reflectance spectroscopy and multispectral imaging was studied. Changes of diffuse reflectance spectra in spectral range from 500 to 600 nm were observed after 405 nm, 473 nm and 532 nm laser provocation, leading to conclusion that the content of skin hemoglobin has changed. Peaks in spectral absorbance (optical density) curves corresponded to well-known oxy-hemoglobin absorbance peaks at 542 and 577 nm.

  2. Diffuse Reflectance Mid-Infrared Spectroscopy as a Tool for the Identification of Surface Contamination on Sandblasted Metals

    NASA Technical Reports Server (NTRS)

    Powell, Louis G.; Barber, Tye E.; Neu, John T.; Nerren, Billy H.

    1997-01-01

    The SOC 400 Surface Inspection Machine/Infrared (SIMIR) is a small, ruggedized Fourier transform infrared spectrometer having dedicated diffuse reflectance optics. The SOC 400 was designed for the purpose of detecting (qualitatively and quantitatively) oil stains on the inside surface of solid rocket motor casings in the as-sandblasted and cleaned condition at levels approaching 1 mg. sq ft. The performance of this instrument is described using spectral mapping techniques.

  3. Prediction of erodibility in Oxisols using iron oxides, soil color and diffuse reflectance spectroscopy

    NASA Astrophysics Data System (ADS)

    Arantes Camargo, Livia; Marques, José, Jr.

    2015-04-01

    The prediction of erodibility using indirect methods such as diffuse reflectance spectroscopy could facilitate the characterization of the spatial variability in large areas and optimize implementation of conservation practices. The aim of this study was to evaluate the prediction of interrill erodibility (Ki) and rill erodibility (Kr) by means of iron oxides content and soil color using multiple linear regression and diffuse reflectance spectroscopy (DRS) using regression analysis by least squares partial (PLSR). The soils were collected from three geomorphic surfaces and analyzed for chemical, physical and mineralogical properties, plus scanned in the spectral range from the visible and infrared. Maps of spatial distribution of Ki and Kr were built with the values calculated by the calibrated models that obtained the best accuracy using geostatistics. Interrill-rill erodibility presented negative correlation with iron extracted by dithionite-citrate-bicarbonate, hematite, and chroma, confirming the influence of iron oxides in soil structural stability. Hematite and hue were the attributes that most contributed in calibration models by multiple linear regression for the prediction of Ki (R2 = 0.55) and Kr (R2 = 0.53). The diffuse reflectance spectroscopy via PLSR allowed to predict Interrill-rill erodibility with high accuracy (R2adj = 0.76, 0.81 respectively and RPD> 2.0) in the range of the visible spectrum (380-800 nm) and the characterization of the spatial variability of these attributes by geostatistics.

  4. Diagnostic power of diffuse reflectance spectroscopy for targeted detection of breast lesions with microcalcifications

    PubMed Central

    Soares, Jaqueline S.; Barman, Ishan; Dingari, Narahara Chari; Volynskaya, Zoya; Liu, Wendy; Klein, Nina; Plecha, Donna; Dasari, Ramachandra R.; Fitzmaurice, Maryann

    2013-01-01

    Microcalcifications geographically target the location of abnormalities within the breast and are of critical importance in breast cancer diagnosis. However, despite stereotactic guidance, core needle biopsy fails to retrieve microcalcifications in up to 15% of patients. Here, we introduce an approach based on diffuse reflectance spectroscopy for detection of microcalcifications that focuses on variations in optical absorption stemming from the calcified clusters and the associated cross-linking molecules. In this study, diffuse reflectance spectra are acquired ex vivo from 203 sites in fresh biopsy tissue cores from 23 patients undergoing stereotactic breast needle biopsies. By correlating the spectra with the corresponding radiographic and histologic assessment, we have developed a support vector machine-derived decision algorithm, which shows high diagnostic power (positive predictive value and negative predictive value of 97% and 88%, respectively) for diagnosis of lesions with microcalcifications. We further show that these results are robust and not due to any spurious correlations. We attribute our findings to the presence of proteins (such as elastin), and desmosine and isodesmosine cross-linkers in the microcalcifications. It is important to note that the performance of the diffuse reflectance decision algorithm is comparable to one derived from the corresponding Raman spectra, and the considerably higher intensity of the reflectance signal enables the detection of the targeted lesions in a fraction of the spectral acquisition time. Our findings create a unique landscape for spectroscopic validation of breast core needle biopsy for detection of microcalcifications that can substantially improve the likelihood of an adequate, diagnostic biopsy in the first attempt. PMID:23267090

  5. Noninvasive detection of skin cancers by measuring optical properties of tissues

    NASA Astrophysics Data System (ADS)

    Wang, Lihong V.; Jacques, Steven L.

    1995-05-01

    Skin cancer is the most frequently occurring cancer of all cancers. Each yea rover 500,000 new cases of skin cancer will be detected. A high percentage of skin cancers are diseases in which fatalities can be all but eliminated and morbidity reduced if detected early and treated properly. These skin lesions are distinguished generally by subjective visual inspection and their definitive diagnosis requires time-consuming expensive histopathological evaluation of excisional or incisional biopsies. In vivo experimental evidence published in the literature has shown that cancerous skin lesions have different total diffuse reflectance spectra than non- cancerous lesions or normal skin. Therefore, cancerous skin lesions may be differentiated from non-cancerous skin lesions by comparing the optical properties of the skin lesions with those of the surrounding normal skin sites, where the optical properties of the normal skin sites are used to account for different types of skin or different areas of skin. We have demonstrated that the effect of melanin concentration on the diffuse reflectance may be removed by extrapolating the reflectance at different wavelengths to an apparent pivot point. Because the concentration of melanin does not indicate malignancy, the removal of its effect is important to avoid false detection. The total diffuse reflectance depends on the albedo and anisotropy of tissues. Therefore, the total diffuse reflectance will remain the same as long as the anisotropy and the ratio between the absorption coefficient and the reduced scattering coefficient remain the same. Separating the absorption and scattering effects should enhance the detection sensitivity of skin cancers.

  6. Computation of diffuse sky irradiance from multidirectional radiance measurements

    NASA Technical Reports Server (NTRS)

    Ahmad, Suraiya P.; Middleton, Elizabeth M.; Deering, Donald W.

    1987-01-01

    Accurate determination of the diffuse solar spectral irradiance directly above the land surface is important in characterizing the reflectance properties of these surfaces, especially vegetation canopies. This determination is also needed to infer the net radiation budget of the earth-atmosphere system above these surfaces. An algorithm is developed here for the computation of hemispheric diffuse irradiance using the measurements from an instrument called PARABOLA, which rapidly measures upwelling and downwelling radiances in three selected wavelength bands. The validity of the algorithm is established from simulations. The standard reference data set of diffuse radiances of Dave (1978), obtained by solving the radiative transfer equation numerically for realistic atmospheric models, is used to simulate PARABOLA radiances. Hemispheric diffuse irradiance is estimated from a subset of simulated radiances by using the algorithm described. The algorithm is validated by comparing the estimated diffuse irradiance with the true diffuse irradiance of the standard data set. The validations include sensitivity studies for two wavelength bands (visible, 0.65-0.67 micron; near infrared, 0.81-0.84 micron), different atmospheric conditions, solar elevations, and surface reflectances. In most cases the hemispheric diffuse irradiance computed from simulated PARABOLA radiances and the true irradiance obtained from radiative transfer calculations agree within 1-2 percent. This technique can be applied to other sampling instruments designed to estimate hemispheric diffuse sky irradiance.

  7. Out in the cold: the hypothermic heart response

    PubMed Central

    Nabeel, Yassar; Ali, Omair

    2014-01-01

    We present an interesting case of a 49-year-old woman with hypothermia and associated Osborn waves (also called J waves) on ECG. She was found on the floor of her home and difficult to arouse. On arrival to the emergency department (ED), her rectal temperature was 87.5°F. ECG showed Osborn waves in diffuse leads. She was intubated in the ED and was started on vasopressor support for hypotension refractory to intravenous fluid boluses. She was transferred to the critical care unit for continued respiratory and cardiovascular support. With active external rewarming her core body temperature continued to improve. Blood pressure also improved and vasopressor was tapered off. She was extubated and was transferred to the medical floor for continued supportive care. Osborn waves on ECG resolved within 12 h of achieving normal range body temperature. The patient was eventually discharged home with medical follow-up. PMID:25406217

  8. Out in the cold: the hypothermic heart response.

    PubMed

    Nabeel, Yassar; Ali, Omair

    2014-11-18

    We present an interesting case of a 49-year-old woman with hypothermia and associated Osborn waves (also called J waves) on ECG. She was found on the floor of her home and difficult to arouse. On arrival to the emergency department (ED), her rectal temperature was 87.5°F. ECG showed Osborn waves in diffuse leads. She was intubated in the ED and was started on vasopressor support for hypotension refractory to intravenous fluid boluses. She was transferred to the critical care unit for continued respiratory and cardiovascular support. With active external rewarming her core body temperature continued to improve. Blood pressure also improved and vasopressor was tapered off. She was extubated and was transferred to the medical floor for continued supportive care. Osborn waves on ECG resolved within 12 h of achieving normal range body temperature. The patient was eventually discharged home with medical follow-up. 2014 BMJ Publishing Group Ltd.

  9. Diffuse reflectance startigraphy - a new method in the study of loess (?)

    NASA Astrophysics Data System (ADS)

    József, Szeberényi; Balázs, Bradák; Klaudia, Kiss; József, Kovács; György, Varga; Réka, Balázs; Viczián, István

    2017-04-01

    The different varieties of loess (and intercalated paleosol layers) together constitute one of the most widespread terrestrial sediments, which was deposited, altered, and redeposited in the course of the changing climatic conditions of the Pleistocene. To reveal more information about Pleistocene climate cycles and/or environments the detailed lithostratigraphical subdivision and classification of the loess variations and paleosols are necessary. Beside the numerous method such as various field measurements, semi-quantitative tests and laboratory investigations, diffuse reflectance spectroscopy (DRS) is one of the well applied method on loess/paleosol sequences. Generally, DRS has been used to separate the detrital and pedogenic mineral component of the loess sections by the hematite/goethite ratio. DRS also has been applied as a joint method of various environmental magnetic investigations such as magnetic susceptibility- and isothermal remanent magnetization measurements. In our study the so-called "diffuse reflectance stratigraphy method" were developed. At First, complex mathematical method was applied to compare the results of the spectral reflectance measurements. One of the most preferred multivariate methods is cluster analysis. Its scope is to group and compare the loess variations and paleosol based on the similarity and common properties of their reflectance curves. In the Second, beside the basic subdivision of the profiles by the different reflectance curves of the layers, the most characteristic wavelength section of the reflectance curve was determined. This sections played the most important role during the classification of the different materials of the section. The reflectance value of individual samples, belonged to the characteristic wavelength were depicted in the function of depth and well correlated with other proxies like grain size distribution and magnetic susceptibility data. The results of the correlation showed the significance of the "combined reflectance stratigraphy" as a stratigraphical method and as an environmental proxy also.

  10. Offering within-category food swaps to reduce energy density of food purchases: a study using an experimental online supermarket.

    PubMed

    Forwood, Suzanna E; Ahern, Amy L; Marteau, Theresa M; Jebb, Susan A

    2015-06-25

    Swaps are often used to encourage healthier food choices, but there is little evidence of their effectiveness. The current study assessed the impact of offering swaps on groceries purchased within a bespoke online supermarket; specifically the objective was to measure the impact on energy density (ED) of food purchases following the offer of lower ED alternatives (a) at point of selection or at checkout, and (b) with or without explicit consent to receive swap prompts. Participants were asked to complete a 12-item shopping task within an online shopping platform, developed for studying food purchasing. 1610 adults were randomly assigned to a no swap control condition or to one of four interventions: consented swaps at selection; consented swaps at checkout; imposed swaps at selection; or imposed swaps at checkout. Each swap presented two lower ED options from the same category as the participant's chosen food. Swap acceptance rate and purchased food ED were the primary outcomes. Of the mean 12.36 (SD 1.26) foods purchased, intervention participants were offered a mean of 4.1 (SD 1.68) swaps, with the potential to reduce the ED of purchased food (effect (95% CI): -83 kJ/100 g (-110 - -56), p = <0.0001). A median of one swap (IQR 0 to 2) was accepted, not significantly reducing the purchased food ED (effect (95% CI): -24 kJ/100 g (4 - -52), p = 0.094). More swaps were accepted when offered at selection than at checkout (OR (95% CI) = 1.224 (1.11 - 1.35), p < 0.0001), but no differences were seen with consent. Purchased food ED was unaffected by point of swap or consent, but reduced with number of swaps accepted (effect per swap (95% CI) = -24 kJ/100 g (-35 - -14), p < 0.0001). Within category swaps did not reduce the ED of food purchases reflecting the observation that the use of swaps within an on-line shopping platform offered small potential gains in ED and a minority was accepted.

  11. Some Historical Resources for Teaching about Curved Mirrors.

    ERIC Educational Resources Information Center

    Mihas, Pavlos

    2002-01-01

    Presents resources from Alhazens' investigations on curved mirrors that investigate diffuse reflection from the moon's surface, composite mirrors, and the problem of possible points of reflection. (Author/YDS)

  12. Influence of probe pressure on diffuse reflectance spectra of human skin measured in vivo

    NASA Astrophysics Data System (ADS)

    Popov, Alexey P.; Bykov, Alexander V.; Meglinski, Igor V.

    2017-11-01

    Mechanical pressure superficially applied on the human skin surface by a fiber-optic probe influences the spatial distribution of blood within the cutaneous tissues. Upon gradual load of weight on the probe, a stepwise increase in the skin reflectance spectra is observed. The decrease in the load follows the similar inverse staircase-like tendency. The observed stepwise reflectance spectra changes are due to, respectively, sequential extrusion of blood from the topical cutaneous vascular beds and their filling afterward. The obtained results are confirmed by Monte Carlo modeling. This implies that pressure-induced influence during the human skin diffuse reflectance spectra measurements in vivo should be taken into consideration, in particular, in the rapidly developing area of wearable gadgets for real-time monitoring of various human body parameters.

  13. Combustion Characteristics of Sprays

    DTIC Science & Technology

    1989-08-01

    Lin. T. H.. and Sohrab. S. H. (1987). On the transition oi’diffusion to premixed I’lames in consers.ed ssstem Cornhusio. Flume 68. 73. Mlizutani. Y ...and Nakauima. A. (1973a). Combustion of fuel vapor-drop-air systems: Part 1-Open burner flames. Combust. F/ante 21.14. Mizutani. Y .. and Nakajima. A...AFOSR LES Final Report. AFRPL. Sohrab. S. H.. Ye. Z. Y .. and Law~k C. K. (1984). An experimenial investication on ilame interaction ano the

  14. Predictors of cerebral microembolization during phased radiofrequency ablation of atrial fibrillation: analysis of biophysical parameters from the ablation generator.

    PubMed

    Nagy-Balo, Edina; Kiss, Alexandra; Condie, Catherine; Stewart, Mark; Edes, Istvan; Csanadi, Zoltan

    2014-06-01

    Pulmonary vein isolation with phased radiofrequency current and use of a pulmonary vein ablation catheter (PVAC) has recently been associated with a high incidence of clinically silent brain infarcts on diffusion-weighted magnetic resonance imaging and a high microembolic signal (MES) count detected by transcranial Doppler. The purpose of this study was to investigate the potential correlation between different biophysical parameters of energy delivery (ED) and MES generation during PVAC ablation. MES counts during consecutive PVAC ablations were recorded for each ED and time stamped for correlation with temperature, power, and impedance data from the GENius 14.4 generator. Additionally, catheter-tissue contact was characterized by the template deviation score, calculated by comparing the temperature curve with an ideal template representing good contact, and by the respiratory contact failure score, to quantify temperature variations indicative of intermittent contact due to respiration. A total of 834 EDs during 48 PVAC ablations were analyzed. A significant increase in MES count was associated with a lower average temperature, a temperature integral over 62°C, a higher average power, the total energy delivered, higher respiration and template deviation scores (P <.0001), and simultaneous ED to the most proximal and distal poles of the PVAC (P <.0001). MES generation during ablation is related to different indicators of poor electrode-tissue contact, the total power delivered, and the interaction between the most distal and the most proximal electrodes. Copyright © 2014. Published by Elsevier Inc.

  15. Adsorption of C.I. Reactive Red 228 and Congo Red dye from aqueous solution by amino-functionalized Fe3O4 particles: kinetics, equilibrium, and thermodynamics.

    PubMed

    Yan, Ting-guo; Wang, Li-Juan

    2014-01-01

    A magnetic adsorbent was synthesized by γ-aminopropyltriethoxysilane (APTES) modification of Fe(3)O(4) particles using a two-step process. Scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and vibration sample magnetometry were used to characterize the obtained magnetic adsorbent. EDS and XPS showed that APTES polymer was successfully introduced onto the as-prepared Fe(3)O(4)/APTES particle surfaces. The saturation magnetization of the magnetic adsorbent was around 65 emu g(-1), which indicated that the dye can be removed fast and efficiently from aqueous solution with an external magnetic field. The maximum adsorption capacities of Fe(3)O(4)/APTES for C.I. Reactive Red 228 (RR 228) and Congo Red (CR) were 51.4 and 118.8 mg g(-1), respectively. The adsorption of C.I. Reactive Red 228 (RR 228) and Congo Red (CR) on Fe(3)O(4)/APTES particles corresponded well to the Langmuir model and the Freundlich model, respectively. The adsorption processes for RR 228 and CR followed the pseudo-second-order model. The Boyd's film-diffusion model showed that film diffusion also played a major role in the studied adsorption processes for both dyes. Thermodynamic study indicated that both of the adsorption processes of the two dyes are spontaneous exothermic.

  16. The impact of forest structure and light utilization on carbon cycling in tropical forests

    NASA Astrophysics Data System (ADS)

    Morton, D. C.; Longo, M.; Leitold, V.; Keller, M. M.

    2015-12-01

    Light competition is a fundamental organizing principle of forest ecosystems, and interactions between forest structure and light availability provide an important constraint on forest productivity. Tropical forests maintain a dense, multi-layered canopy, based in part on abundant diffuse light reaching the forest understory. Climate-driven changes in light availability, such as more direct illumination during drought conditions, therefore alter the potential productivity of forest ecosystems during such events. Here, we used multi-temporal airborne lidar data over a range of Amazon forest conditions to explore the influence of forest structure on gross primary productivity (GPP). Our analysis combined lidar-based observations of canopy illumination and turnover in the Ecosystem Demography model (ED, version 2.2). The ED model was updated to specifically account for regional differences in canopy and understory illumination using lidar-derived measures of canopy light environments. Model simulations considered the influence of forest structure on GPP over seasonal to decadal time scales, including feedbacks from differential productivity between illuminated and shaded canopy trees on mortality rates and forest composition. Finally, we constructed simple scenarios with varying diffuse and direct illumination to evaluate the potential for novel plant-climate interactions under scenarios of climate change. Collectively, the lidar observations and model simulations underscore the need to account for spatial heterogeneity in the vertical structure of tropical forests to constrain estimates of tropical forest productivity under current and future climate conditions.

  17. Diffuse reflectance spectra measured in vivo in human tissues during Photofrin-mediated pleural photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Finlay, Jarod C.; Zhu, Timothy C.; Dimofte, Andreea; Friedberg, Joseph S.; Hahn, Stephen M.

    2006-02-01

    Optimal delivery of light in photodynamic therapy (PDT) requires not only optimal placement and power of light sources, but knowledge of the dynamics of light propagation in the tissue being treated and in the surrounding normal tissue, and of their respective accumulations of sensitizer. In an effort to quantify both tissue optical properties and sensitizer distribution, we have measured fluorescence emission and diffuse reflectance spectra at the surface of a variety of tissue types in the thoracic cavities of human patients. The patients studied here were enrolled in Phase II clinical trials of Photofrin-mediated PDT for the treatment of non-small cell lung cancer and cancers with pleural effusion. Patients were given Photofrin at dose of 2 mg per kg body weight 24 hours prior to treatment. Each patient received surgical resection of the affected lung and pleura. Patients received intracavity PDT at 630nm to a dose of 30 J/cm2, as determined by isotropic detectors sutured to the cavity walls. We measured the diffuse reflectance spectra before and after PDT in various positions within the cavity, including tumor, diaphragm, pericardium, skin, and chest wall muscle in 5 patients. The measurements we acquired using a specially designed fiber optic-based probe consisting of one fluorescence excitation fiber, one white light delivery fiber, and 9 detection fibers spaced at distances from 0.36 to 7.8 mm from the source, all of which are imaged via a spectrograph onto a CCD, allowing measurement of radially-resolved diffuse reflectance and fluorescence spectra. The light sources for these two measurements (a 403-nm diode laser and a halogen lamp, respectively) were blocked by computer-controlled shutters, allowing sequential fluorescence, reflectance, and background acquisition. The diffuse reflectance was analyzed to determine the absorption and scattering spectra of the tissue and from these, the concentration and oxygenation of hemoglobin and the local drug uptake. The total hemoglobin concentration in normal tissues varied from 50 to 300 µM, and the oxygen saturation was generally above 60%. One tumor measured exhibited higher hemoglobin concentration and lower saturation.

  18. Finite element modeling of diffusion and partitioning in biological systems: the infinite composite medium problem.

    PubMed

    Missel, P J

    2000-01-01

    Four methods are proposed for modeling diffusion in heterogeneous media where diffusion and partition coefficients take on differing values in each subregion. The exercise was conducted to validate finite element modeling (FEM) procedures in anticipation of modeling drug diffusion with regional partitioning into ocular tissue, though the approach can be useful for other organs, or for modeling diffusion in laminate devices. Partitioning creates a discontinuous value in the dependent variable (concentration) at an intertissue boundary that is not easily handled by available general-purpose FEM codes, which allow for only one value at each node. The discontinuity is handled using a transformation on the dependent variable based upon the region-specific partition coefficient. Methods were evaluated by their ability to reproduce a known exact result, for the problem of the infinite composite medium (Crank, J. The Mathematics of Diffusion, 2nd ed. New York: Oxford University Press, 1975, pp. 38-39.). The most physically intuitive method is based upon the concept of chemical potential, which is continuous across an interphase boundary (method III). This method makes the equation of the dependent variable highly nonlinear. This can be linearized easily by a change of variables (method IV). Results are also given for a one-dimensional problem simulating bolus injection into the vitreous, predicting time disposition of drug in vitreous and retina.

  19. Statistical process control: separating signal from noise in emergency department operations.

    PubMed

    Pimentel, Laura; Barrueto, Fermin

    2015-05-01

    Statistical process control (SPC) is a visually appealing and statistically rigorous methodology very suitable to the analysis of emergency department (ED) operations. We demonstrate that the control chart is the primary tool of SPC; it is constructed by plotting data measuring the key quality indicators of operational processes in rationally ordered subgroups such as units of time. Control limits are calculated using formulas reflecting the variation in the data points from one another and from the mean. SPC allows managers to determine whether operational processes are controlled and predictable. We review why the moving range chart is most appropriate for use in the complex ED milieu, how to apply SPC to ED operations, and how to determine when performance improvement is needed. SPC is an excellent tool for operational analysis and quality improvement for these reasons: 1) control charts make large data sets intuitively coherent by integrating statistical and visual descriptions; 2) SPC provides analysis of process stability and capability rather than simple comparison with a benchmark; 3) SPC allows distinction between special cause variation (signal), indicating an unstable process requiring action, and common cause variation (noise), reflecting a stable process; and 4) SPC keeps the focus of quality improvement on process rather than individual performance. Because data have no meaning apart from their context, and every process generates information that can be used to improve it, we contend that SPC should be seriously considered for driving quality improvement in emergency medicine. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Modeling of Light Reflection from Human Skin

    NASA Astrophysics Data System (ADS)

    Delgado, J. A.; Cornejo, A.; Rivas-Silva, J. F.; Rodríguez, E. E.

    2006-09-01

    In this work a two-layer model is used to simulate the spectral reflectance of adult human skin. We report and discuss diffuse reflectance spectra of this model for three values of the volume fraction of melanosomes fme, namely a) lightly pigmented skin fme = 4%, b) moderately pigmented skin fme = 14% and c) heavily pigmented skin fme = 30% at a volume fraction of blood fbl = 0.2%. We also considered the modeling of reflectance spectra for two values of fbl (0.2% and 1%) with fme = 4%. Both simulations were done in the 400-700 nm spectral range using the Monte Carlo simulation code MCML in standard C. Results showed that the principal signatures of human skin reflectance spectrum are obtained with this model and that it could be of valuable use to made predictions of diffuse reflectance of human skin for different values of the parameters related to skin characterization. These parameters can be associated to distinct medical conditions, such as erythema, jaundice, etc.

  1. Galerkin methods for Boltzmann-Poisson transport with reflection conditions on rough boundaries

    NASA Astrophysics Data System (ADS)

    Morales Escalante, José A.; Gamba, Irene M.

    2018-06-01

    We consider in this paper the mathematical and numerical modeling of reflective boundary conditions (BC) associated to Boltzmann-Poisson systems, including diffusive reflection in addition to specularity, in the context of electron transport in semiconductor device modeling at nano scales, and their implementation in Discontinuous Galerkin (DG) schemes. We study these BC on the physical boundaries of the device and develop a numerical approximation to model an insulating boundary condition, or equivalently, a pointwise zero flux mathematical condition for the electron transport equation. Such condition balances the incident and reflective momentum flux at the microscopic level, pointwise at the boundary, in the case of a more general mixed reflection with momentum dependant specularity probability p (k →). We compare the computational prediction of physical observables given by the numerical implementation of these different reflection conditions in our DG scheme for BP models, and observe that the diffusive condition influences the kinetic moments over the whole domain in position space.

  2. Photocatalytic performance of Ag doped SnO2 nanoparticles modified with curcumin

    NASA Astrophysics Data System (ADS)

    Vignesh, K.; Hariharan, R.; Rajarajan, M.; Suganthi, A.

    2013-07-01

    Visible light active Ag doped SnO2 nanoparticles modified with curcumin (Cur-Ag-SnO2) have been prepared by a combined precipitation and chemical impregnation route. The optical properties, phase structures and morphologies of the as-prepared nanoparticles were characterized using UV-visible diffuse reflectance spectra (UV-vis-DRS), X-ray powder diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and X-ray photoelectron spectroscopy (XPS). The surface area was measured by Brunauer. Emmett. Teller (B.E.T) analysis. Compared to bare SnO2, the surface modified photocatalysts (Ag-SnO2 and Cur-Ag-SnO2) showed a red shift in the visible region. The photocatalytic activity was monitored via the degradation of rose bengal (RB) dye and the results revealed that Cur-Ag-SnO2 shows better photocatalytic activity than that of Ag-SnO2 and SnO2. The superior photocatalytic activity of Cur-Ag-SnO2 could be attributed to the effective electron-hole separation by surface modification. The effect of photocatalyst concentration, initial dye concentration and electron scavenger on the photocatalytic activity was examined in detail. Furthermore, the antifungal activity of the photocatalysts and the reusability of Cur-Ag-SnO2 were tested.

  3. Layered double hydroxide of Cd-Al/C for the Mineralization and De-coloration of Dyes in Solar and Visible Light Exposure

    NASA Astrophysics Data System (ADS)

    Khan, Shahid Ali; Khan, Sher Bahadar; Asiri, Abdullah M.

    2016-11-01

    Cd-Al/C layered double hydroxide (Cd-Al/C-LDH) and Cd-Sb/C nanocatalyst are reported here for the de-coloration and mineralization of organic dyes. These catalysts were largely characterized by FESEM, EDS, XRD, FTIR, XPS, PL and DRS. The diffuse reflectance data showed a band gap at 2.92 and 2.983 eV for Cd-Al/C-LDH and Cd-Sb/C respectively. The band gap suggested that both catalysts work well in visible range. The photoluminescence spectra indicated a peak at 623 nm for both the catalysts which further support the effectiveness of the respective catalyst in visible range. Both catalysts also showed good recyclability and durability till 4th cycle. Five dyes, acridine orange (AO), malachite green (MG), crystal violet (CV), congo red (CR) and methyl orange (MO) were used in this experiment. Various parameters of different light intensity such as visible, ultraviolet, sunlight and dark condition are observed for the de-coloration of these dyes. The de-coloration phenomenon was proceeded through adsorption assisted phot-degradation. The low cost, abundant nature, good recyclability and better dye removal efficiency make these catalysts suitable candidates for the de-coloration and mineralization of organic dyes.

  4. Novel room temperature synthesis of ZnO nanosheets, characterization and potentials in light harvesting applications and electrochemical devices.

    PubMed

    Mansournia, Mohammadreza; Rafizadeh, Somayeh; Hosseinpour-Mashkani, S Mostafa; Motaghedifard, Mohammad Hassan

    2016-08-01

    Zinc oxide nanosheets (ZnONSs) were successfully synthesized using Zn(NO3)2·4H2O as the starting reagent in ammonia atmosphere at room temperature by a novel gas-solution precipitation method. XRD and EDS patterns indicated that pure ZnONSs were produced only in 15min reaction time. Besides, investigating the optical properties of the as-prepared ZnO nanosheets using UV-Vis diffused reflectance spectroscopy (DRS) exhibited their semiconducting property by revealing one optical band gap in 3.3eV. Moreover, rhodamine B and methylene blue degradation were used as a probe reaction to test the as-synthesized ZnONSs photoactivity. Furthermore, a possible reaction mechanism for ZnONSs formation was discussed. On the other hand, operation of ZnONSs in Dye-sensitized solar cell (DSSC) was investigated by current density-voltage (Jsc-Voc) curve. Finally, a pencil graphite electrode was decorated using ZnONSs and pure MWCNT to provide an electrochemical device for Pb(+2) ions sensing. This modified electrode showed agreeable responses to trace amounts of Pb(+2) in NaOAC/HOAC buffer solutions. The limit of detection was found to be 0.112nmolL(-1) for Pb(+2). Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Self-assembly and enhanced photocatalytic properties of BiOI hollow microspheres via a reactable ionic liquid.

    PubMed

    Xia, Jiexiang; Yin, Sheng; Li, Huaming; Xu, Hui; Yan, Yongsheng; Zhang, Qi

    2011-02-01

    BiOI uniform flowerlike hollow microspheres with a hole in its surface structures have been successfully synthesized through an EG-assisted solvothermal process in the presence of ionic liquid 1-butyl-3-methylimidazolium iodine ([Bmim]I). The as-prepared samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDS), nitrogen sorption, and diffuse reflectance spectroscopy (DRS). A possible formation mechanism for the growth of hollow microspheres was discussed. During the reactive process, ionic liquid not only acted as solvents and templates but also as an I source for the fabrication of BiOI hollow microspheres and was vital for the structure of hollow microspheres. Additionally, we evaluated the photocatalytic activities of BiOI on the degradation of methyl orange (MO) under visible light irradiation and found that as-prepared BiOI hollow microspheres exhibited higher photocatalytic activity than BiOI nanoplates and TiO(2) (Degussa, P25) did. On the basis of such analysis, it can be assumed that the enhanced photocatalytic activities of BiOI hollow microspheres could be ascribed to its energy band structure, high BET surface area, high surface-to-volume ratios, and light absorbance.

  6. Facile fabrication of CuO-Pb2O3 nanophotocatalyst for efficient degradation of Rose Bengal dye under visible light irradiation

    NASA Astrophysics Data System (ADS)

    Kamaraj, Eswaran; Somasundaram, Sivaraman; Balasubramani, Kavitha; Eswaran, Muthu Prema; Muthuramalingam, Rajarajan; Park, Sanghyuk

    2018-03-01

    A p-type CuO/n-type Pb2O3 heterojunction photocatalyst was prepared by a simple wet chemical process and the photocatalytic ability was evaluated for the degradation of Rose Bengal (RB) under visible light irradiation. Synthesized nanocatalysts were characterized by X-ray diffraction (XRD), UV-vis diffuse reflectance spectroscopy (DRS), scanning electron microscopy (SEM), transmission electron microscopy (TEM), Energy-dispersive X-ray spectroscopy (EDS), Brunauer-Emmett-Teller (BET) surface area analysis, and X-ray photoelectron spectroscopy (XPS). The p-n heterojunction of CuO-Pb2O3 nanostructures can promote the light absorption capability of photocatalyst and charge separation of electron-hole pairs. Photodegradation assays showed that the addition of CuO effectively enhanced the photocatalytic activity of CuO-Pb2O3 under visible light irradiation (λmax > 420 nm). Compared with pure Pb2O3 and CuO, the CuO-Pb2O3 exhibited significantly enhanced photocatalytic degradation activity. The reaction rate constant of CuO-Pb2O3 is 0.092 min-1, which is much higher than those of CuO (0.073 min-1) and Pb2O3 (0.045 min-1).

  7. Recognition and management of seizures in children in emergency departments.

    PubMed

    Caplan, Edward; Dey, Indranil; Scammell, Andrea; Burnage, Katy; Paul, Siba Prosad

    2016-09-01

    Seizure is defined as 'a sudden surge of electrical activity in the brain, which usually affects how a person appears or acts for a short time'. Children who have experienced seizures commonly present to emergency departments (EDs), and detailed history taking will usually help differentiate between epileptic and non-epileptic events. ED nurses are often the first health professionals to manage children with seizures, and this is best done by following the ABCDE approach. Treatment involves termination of seizures with anticonvulsants, and children may need other symptomatic management. Seizures in children can be an extremely distressing experience for parents, who should be supported and kept informed by experienced ED nurses. Nurses also play a vital role in educating parents on correct administration of anticonvulsants and safety advice. This article discusses the aetiology, clinical presentation, diagnosis and management of children with seizures, with particular emphasis on epilepsy. It includes two reflective case studies to highlight the challenges faced by healthcare professionals managing children who present with convulsions.

  8. On the possibility of spectroscopic cancer diagnostics

    NASA Astrophysics Data System (ADS)

    Khairullina, Alphiya Y.; Oleinik, Tatiana V.; Korolevich, Alexander N.; Sevkovsky, Yacob I.

    1993-07-01

    The diffuse reflection and transmission coefficients, other optical parameters of normal and cancer tissues have been investigated in visible and infrared spectra. The optimal spectral range for distinguishing the cancer is found. The spectral absorption coefficients and size of cells parameter determined using our approach are analyzed to be different for normal and pathological tissues. The method is proposed for calculating the diffuse reflectance and transmittance of multiple tissue layers. The investigations have shown that cancer may be distinguished under the layers of skin and normal tissue.

  9. Estimation of biomedical optical properties by simultaneous use of diffuse reflectometry and photothermal radiometry: investigation of light propagation models

    NASA Astrophysics Data System (ADS)

    Fonseca, E. S. R.; de Jesus, M. E. P.

    2007-07-01

    The estimation of optical properties of highly turbid and opaque biological tissue is a difficult task since conventional purely optical methods rapidly loose sensitivity as the mean photon path length decreases. Photothermal methods, such as pulsed or frequency domain photothermal radiometry (FD-PTR), on the other hand, show remarkable sensitivity in experimental conditions that produce very feeble optical signals. Photothermal Radiometry is primarily sensitive to absorption coefficient yielding considerably higher estimation errors on scattering coefficients. Conversely, purely optical methods such as Local Diffuse Reflectance (LDR) depend mainly on the scattering coefficient and yield much better estimates of this parameter. Therefore, at moderate transport albedos, the combination of photothermal and reflectance methods can improve considerably the sensitivity of detection of tissue optical properties. The authors have recently proposed a novel method that combines FD-PTR with LDR, aimed at improving sensitivity on the determination of both optical properties. Signal analysis was performed by global fitting the experimental data to forward models based on Monte-Carlo simulations. Although this approach is accurate, the associated computational burden often limits its use as a forward model. Therefore, the application of analytical models based on the diffusion approximation offers a faster alternative. In this work, we propose the calculation of the diffuse reflectance and the fluence rate profiles under the δ-P I approximation. This approach is known to approximate fluence rate expressions better close to collimated sources and boundaries than the standard diffusion approximation (SDA). We extend this study to the calculation of the diffuse reflectance profiles. The ability of the δ-P I based model to provide good estimates of the absorption, scattering and anisotropy coefficients is tested against Monte-Carlo simulations over a wide range of scattering to absorption ratios. Experimental validation of the proposed method is accomplished by a set of measurements on solid absorbing and scattering phantoms.

  10. Reflections in computer modeling of rooms: Current approaches and possible extensions

    NASA Astrophysics Data System (ADS)

    Svensson, U. Peter

    2005-09-01

    Computer modeling of rooms is most commonly done by some calculation technique that is based on decomposing the sound field into separate reflection components. In a first step, a list of possible reflection paths is found and in a second step, an impulse response is constructed from the list of reflections. Alternatively, the list of reflections is used for generating a simpler echogram, the energy decay as function of time. A number of geometrical acoustics-based methods can handle specular reflections, diffuse reflections, edge diffraction, curved surfaces, and locally/non-locally reacting surfaces to various degrees. This presentation gives an overview of how reflections are handled in the image source method and variants of the ray-tracing methods, which are dominating today in commercial software, as well as in the radiosity method and edge diffraction methods. The use of the recently standardized scattering and diffusion coefficients of surfaces is discussed. Possibilities for combining edge diffraction, surface scattering, and impedance boundaries are demonstrated for an example surface. Finally, the number of reflection paths becomes prohibitively high when all such combinations are included as demonstrated for a simple concert hall model. [Work supported by the Acoustic Research Centre through NFR, Norway.

  11. The Inspir=Ed Project: A Holistic Early Childhood Program for Enhancing Parent-Child Well-Being

    ERIC Educational Resources Information Center

    Hanckel, Jane; Segal, Leonie

    2016-01-01

    All Indigenous communities have a time-tested child-rearing knowledge base that reflects and honors their cultural beliefs and historical experiences. Many of these communities emphasize group harmony and collaboration and respect for the natural environment--competencies that are increasingly important on our crowded and depleted planet.…

  12. Grants to Faith-Based Organizations, Fiscal Year 2004

    ERIC Educational Resources Information Center

    The White House, 2005

    2005-01-01

    The data included in this report reflects a review of 151 Federally administered programs at six Federal agencies (HHS, HUD, ED, DOL, DOJ, and USDA), and 17 program areas at USAID. It includes only those programs that utilize competitively awarded grants for which faith-based and community organizations (FBCOs) were eligible to apply and…

  13. "Clones," Codes, and Conflicts of Interest in Cartooning: Cartoonists and Editors Look at Ethics.

    ERIC Educational Resources Information Center

    Riffe, Daniel; And Others

    A study examined differences between political cartoonists and op-ed page editors on both traditional ethical issues (such as conflicts of interest) and the special, style-related concerns of editorial cartoonists. Hypotheses proposed were that editors and cartoonists (1) would condemn "cloning" or copying, reflecting an ethical…

  14. Using "Swivl" Robotic Technology in Teacher Education Preparation: A Pilot Study

    ERIC Educational Resources Information Center

    Franklin, Robin Kesterson; O'Neill Mitchell, Justin; Walters, Kari Siko; Livingston, Beth; Lineberger, Matthew Blake; Putman, Cynthia; Yarborough, Reba; Karges-Bone, Linda

    2018-01-01

    Based on requirements to promote for reflective practice, both CAEP and edTPA suggest adding a video component to clinical practice. This qualitative pilot study evaluated "Swivl" as that potential recording technological device for clinical practice. During a clinical practice cycle at a private university in the southeastern region of…

  15. Clinical Heterogeneity in Patients with the Hypermobility Type of Ehlers-Danlos Syndrome

    ERIC Educational Resources Information Center

    De Wandele, Inge; Rombaut, Lies; Malfait, Fransiska; De Backer, Tine; De Paepe, Anne; Calders, Patrick

    2013-01-01

    EDS-HT is a connective tissue disorder characterized by large inter-individual differences in the clinical presentation, complicating diagnosis and treatment. We aim to describe the clinical heterogeneity and to investigate whether differences in the symptom profile are also reflected as disparity in functional impairment and pain experience. In…

  16. Vectors of Identity Development during the First Year: Black First-Generation Students' Reflections

    ERIC Educational Resources Information Center

    Liversage, Lindi; Naudé, Luzelle; Botha, Anja

    2018-01-01

    In this study, black South African first-generation students' experiences related to identity development during their first year at a higher education institution were explored. Chickering and Reisser's [1993. "Education and Identity." 2nd ed. San Francisco, CA: Jossey-Bass] seven-vector identity development theory served as overarching…

  17. 47 CFR 0.411 - General reference materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... they need subchapter A, containing the general rules, and one of the other volumes, depending upon their area of interest. These four volumes are revised annually to reflect changes in the rules. See... single volume, Radio Laws of the United States (1962 ed.). See §§ 0.405 and 0.414. (b) Regulatory...

  18. Theoretical studies of floating-reference method for NIR blood glucose sensing

    NASA Astrophysics Data System (ADS)

    Shi, Zhenzhi; Yang, Yue; Zhao, Huijuan; Chen, Wenliang; Liu, Rong; Xu, Kexin

    2011-03-01

    Non-invasive blood glucose monitoring using NIR light has been suffered from the variety of optical background that is mainly caused by the change of human body, such as the change of temperature, water concentration, and so on. In order to eliminate these internal influence and external interference a so called floating-reference method has been proposed to provide an internal reference. From the analysis of the diffuse reflectance spectrum, a position has been found where diffuse reflection of light is not sensitive to the glucose concentrations. Our previous work has proved the existence of reference position using diffusion equation. However, since glucose monitoring generally use the NIR light in region of 1000-2000nm, diffusion equation is not valid because of the high absorption coefficient and small source-detector separations. In this paper, steady-state high-order approximate model is used to further investigate the existence of the floating reference position in semi-infinite medium. Based on the analysis of different optical parameters on the impact of spatially resolved reflectance of light, we find that the existence of the floating-reference position is the result of the interaction of optical parameters. Comparing to the results of Monte Carlo simulation, the applicable region of diffusion approximation and higher-order approximation for the calculation of floating-reference position is discussed at the wavelength of 1000nm-1800nm, using the intralipid solution of different concentrations. The results indicate that when the reduced albedo is greater than 0.93, diffusion approximation results are more close to simulation results, otherwise the high order approximation is more applicable.

  19. A comparison of radiosity with current methods of sound level prediction in commercial spaces

    NASA Astrophysics Data System (ADS)

    Beamer, C. Walter, IV; Muehleisen, Ralph T.

    2002-11-01

    The ray tracing and image methods (and variations thereof) are widely used for the computation of sound fields in architectural spaces. The ray tracing and image methods are best suited for spaces with mostly specular reflecting surfaces. The radiosity method, a method based on solving a system of energy balance equations, is best applied to spaces with mainly diffusely reflective surfaces. Because very few spaces are either purely specular or purely diffuse, all methods must deal with both types of reflecting surfaces. A comparison of the radiosity method to other methods for the prediction of sound levels in commercial environments is presented. [Work supported by NSF.

  20. Shading of a computer-generated hologram by zone plate modulation.

    PubMed

    Kurihara, Takayuki; Takaki, Yasuhiro

    2012-02-13

    We propose a hologram calculation technique that enables reconstructing a shaded three-dimensional (3D) image. The amplitude distributions of zone plates, which generate the object points that constitute a 3D object, were two-dimensionally modulated. Two-dimensional (2D) amplitude modulation was determined on the basis of the Phong reflection model developed for computer graphics, which considers the specular, diffuse, and ambient reflection light components. The 2D amplitude modulation added variable and constant modulations: the former controlled the specular light component and the latter controlled the diffuse and ambient components. The proposed calculation technique was experimentally verified. The reconstructed image showed specular reflection that varied depending on the viewing position.

  1. Quantitative interpretations of Visible-NIR reflectance spectra of blood.

    PubMed

    Serebrennikova, Yulia M; Smith, Jennifer M; Huffman, Debra E; Leparc, German F; García-Rubio, Luis H

    2008-10-27

    This paper illustrates the implementation of a new theoretical model for rapid quantitative analysis of the Vis-NIR diffuse reflectance spectra of blood cultures. This new model is based on the photon diffusion theory and Mie scattering theory that have been formulated to account for multiple scattering populations and absorptive components. This study stresses the significance of the thorough solution of the scattering and absorption problem in order to accurately resolve for optically relevant parameters of blood culture components. With advantages of being calibration-free and computationally fast, the new model has two basic requirements. First, wavelength-dependent refractive indices of the basic chemical constituents of blood culture components are needed. Second, multi-wavelength measurements or at least the measurements of characteristic wavelengths equal to the degrees of freedom, i.e. number of optically relevant parameters, of blood culture system are required. The blood culture analysis model was tested with a large number of diffuse reflectance spectra of blood culture samples characterized by an extensive range of the relevant parameters.

  2. Use of polyurethane foam and 3-hydroxy-7,8-benzo-1,2,3,4-tetrahydroquinoline for determination of nitrite by diffuse reflectance spectroscopy and colorimetry.

    PubMed

    Apyari, V V; Dmitrienko, S G; Ostrovskaya, V M; Anaev, E K; Zolotov, Y A

    2008-07-01

    Polyurethane foam (PUF) has been suggested as a solid polymeric reagent for determination of nitrite. The determination is based on the diazotization of end toluidine groups of PUF with nitrite in acidic medium followed by coupling of polymeric diazonium cation with 3-hydroxy-7,8-benzo-1,2,3,4-tetrahydroquinoline. The intensely colored polymeric azodye formed in this reaction can be used as a convenient analytic form for the determination of nitrite by diffuse reflectance spectroscopy (c (min) = 0.7 ng mL(-1)). The possibility of using a desktop scanner, digital camera, and computer data processing for the numerical evaluation of the color intensity of the polymeric azodye has been investigated. A scanner and digital camera can be used for determination of nitrite with the same sensitivity and reproducibility as with diffuse reflectance spectroscopy. The approach developed was applied for determination of nitrite in river water and human exhaled breath condensate.

  3. Distortion correction and cross-talk compensation algorithm for use with an imaging spectrometer based spatially resolved diffuse reflectance system

    NASA Astrophysics Data System (ADS)

    Cappon, Derek J.; Farrell, Thomas J.; Fang, Qiyin; Hayward, Joseph E.

    2016-12-01

    Optical spectroscopy of human tissue has been widely applied within the field of biomedical optics to allow rapid, in vivo characterization and analysis of the tissue. When designing an instrument of this type, an imaging spectrometer is often employed to allow for simultaneous analysis of distinct signals. This is especially important when performing spatially resolved diffuse reflectance spectroscopy. In this article, an algorithm is presented that allows for the automated processing of 2-dimensional images acquired from an imaging spectrometer. The algorithm automatically defines distinct spectrometer tracks and adaptively compensates for distortion introduced by optical components in the imaging chain. Crosstalk resulting from the overlap of adjacent spectrometer tracks in the image is detected and subtracted from each signal. The algorithm's performance is demonstrated in the processing of spatially resolved diffuse reflectance spectra recovered from an Intralipid and ink liquid phantom and is shown to increase the range of wavelengths over which usable data can be recovered.

  4. Modification method to reduce the impact of blood vessel on noncontact discrimination of human blood based on ;M+N; theory

    NASA Astrophysics Data System (ADS)

    Zhang, Linna; Ding, Hongyan; Lin, Ling; Wang, Yimin; Guo, Xin

    2018-01-01

    Noncontact discriminating human blood is significantly crucial for import-export ports and inspection and quarantine departments. We had already demonstrated that visible diffuse reflectance spectroscopy combining PLS-DA method can successfully realize noncontact human blood discrimination. However, the circulated blood vessels may be produced with different materials. The use of various kinds of blood tubes may have a negative effect on the discrimination, based on ;M+N; theory (Li et al., 2016). In this research, we explored the impact of different material of blood vessels, such as glass tube and plastic tube, on the prediction ability of the discrimination model. Furthermore, we searched for the modification method to reduce the influence from the blood tubes. Our work indicated that generalized diffuse reflectance method can greatly improve the discrimination accuracy. This research can greatly facilitate the application of noncontact discrimination method based on visible and near-infrared diffuse reflectance spectroscopy.

  5. Optical spectroscopy for differentiation of liver tissue under distinct stages of fibrosis: an ex vivo study

    NASA Astrophysics Data System (ADS)

    Fabila, D. A.; Hernández, L. F.; de la Rosa, J.; Stolik, S.; Arroyo-Camarena, U. D.; López-Vancell, M. D.; Escobedo, G.

    2013-11-01

    Liver fibrosis is the decisive step towards the development of cirrhosis; its early detection affects crucially the diagnosis of liver disease, its prognosis and therapeutic decision making. Nowadays, several techniques are employed to this task. However, they have the limitation in estimating different stages of the pathology. In this paper we present a preliminary study to evaluate if optical spectroscopy can be employed as an auxiliary tool of diagnosis of biopsies of human liver tissue to differentiate the fibrosis stages. Ex vivo fluorescence and diffuse reflectance spectra were acquired from biopsies using a portable fiber-optic system. Empirical discrimination algorithms based on fluorescence intensity ratio at 500 nm and 680 nm as well as diffuse reflectance intensity at 650 nm were developed. Sensitivity and specificity of around 80% and 85% were respectively achieved. The obtained results show that combined use of fluorescence and diffuse reflectance spectroscopy could represent a novel and useful tool in the early evaluation of liver fibrosis.

  6. Effect of diffusive and nondiffusive surfaces combinations on sound diffusion

    NASA Astrophysics Data System (ADS)

    Shafieian, Masoume; Kashani, Farokh Hodjat

    2010-05-01

    One of room acoustic goals, especially in small to medium rooms, is sound diffusion in low frequencies, which have been the subject of lots of researches. Sound diffusion is a very important consideration in acoustics because it minimizes the coherent reflections that cause problems. It also tends to make an enclosed space sound larger than it is. Diffusion is an excellent alternative or complement to sound absorption in acoustic treatment because it doesn’t really remove much energy, which means it can be used to effectively reduce reflections while still leaving an ambient or live sounding space. Distribution of diffusive and nondiffusive surfaces on room walls affect sound diffusion in room, but the amount, combination, and location of these surfaces are still the matter of question. This paper investigates effects of these issues on room acoustic frequency response in different parts of the room with different source-receiver locations. Room acoustic model based on wave method is used (implemented) which is very accurate and convenient for low frequencies in such rooms. Different distributions of acoustic surfaces on room walls have been introduced to the model and room frequency response results are calculated. For the purpose of comparison, some measurements results are presented. Finally for more smooth frequency response in small and medium rooms, some suggestions are made.

  7. Assessment of Microcirculatory Hemoglobin Levels in Normal and Diabetic Subjects using Diffuse Reflectance Spectroscopy in the Visible Region — a Pilot Study

    NASA Astrophysics Data System (ADS)

    Sujatha, N.; Anand, B. S. Suresh; Nivetha, K. Bala; Narayanamurthy, V. B.; Seshadri, V.; Poddar, R.

    2015-07-01

    Light-based diagnostic techniques provide a minimally invasive way for selective biomarker estimation when tissues transform from a normal to a malignant state. Spectroscopic techniques based on diffuse reflectance characterize the changes in tissue hemoglobin/oxygenation levels during the tissue transformation process. Recent clinical investigations have shown that changes in tissue oxygenation and microcirculation are observed in diabetic subjects in the initial and progressive stages. In this pilot study, we discuss the potential of diffuse reflectance spectroscopy (DRS) in the visible (Vis) range to differentiate the skin microcirculatory hemoglobin levels between normal and advanced diabetic subjects with and without neuropathy. Average concentration of hemoglobin as well as hemoglobin oxygen saturation within the probed tissue volume is estimated for a total of four different sites in the foot sole. The results indicate a statistically significant decrease in average total hemoglobin and increase in hemoglobin oxygen saturation levels for diabetic foot compared with a normal foot. The present study demonstrates the ability of reflectance spectroscopy in the Vis range to determine and differentiate the changes in tissue hemoglobin and hemoglobin oxygen saturation levels in normal and diabetic subjects.

  8. SWIR calibration of Spectralon reflectance factor

    NASA Astrophysics Data System (ADS)

    Georgiev, Georgi T.; Butler, James J.; Cooksey, Catherine; Ding, Leibo; Thome, Kurtis J.

    2011-11-01

    Satellite instruments operating in the reflective solar wavelength region require accurate and precise determination of the Bidirectional Reflectance Factor (BRF) of laboratory-based diffusers used in their pre-flight and on-orbit radiometric calibrations. BRF measurements are required throughout the reflected-solar spectrum from the ultraviolet through the shortwave infrared. Spectralon diffusers are commonly used as a reflectance standard for bidirectional and hemispherical geometries. The Diffuser Calibration Laboratory (DCaL) at NASA's Goddard Space Flight Center is a secondary calibration facility with reflectance measurements traceable to those made by the Spectral Tri-function Automated Reference Reflectometer (STARR) facility at the National Institute of Standards and Technology (NIST). For more than two decades, the DCaL has provided numerous NASA projects with BRF data in the ultraviolet (UV), visible (VIS) and the Near InfraRed (NIR) spectral regions. Presented in this paper are measurements of BRF from 1475 nm to 1625 nm obtained using an indium gallium arsenide detector and a tunable coherent light source. The sample was a 50.8 mm (2 in) diameter, 99% white Spectralon target. The BRF results are discussed and compared to empirically generated data from a model based on NIST certified values of 6°directional-hemispherical spectral reflectance factors from 900 nm to 2500 nm. Employing a new NIST capability for measuring bidirectional reflectance using a cooled, extended InGaAs detector, BRF calibration measurements of the same sample were also made using NIST's STARR from 1475 nm to 1625 nm at an incident angle of 0° and at viewing angle of 45°. The total combined uncertainty for BRF in this ShortWave Infrared (SWIR) range is less than 1%. This measurement capability will evolve into a BRF calibration service in SWIR region in support of NASA remote sensing missions.

  9. Arterial Wave Reflection and Aortic Valve Calcification in an Elderly Community-Based Cohort

    PubMed Central

    Sera, Fusako; Russo, Cesare; Iwata, Shinichi; Jin, Zhezhen; Rundek, Tatjana; Elkind, Mitchell S.V.; Homma, Shunichi; Sacco, Ralph L.; Di Tullio, Marco R.

    2015-01-01

    Background Aortic valve calcification (AVC) without stenosis is common in the elderly, is associated with cardiovascular morbidity and mortality, and may progress to aortic valve stenosis. Arterial stiffness and pulse wave reflection are important components of proximal aortic hemodynamics, but their relationship with AVC is not established. Methods To investigate the relationship of arterial wave reflection and stiffness with AVC, pulse wave analysis and AVC evaluation by echocardiography were performed in 867 participants from the Cardiovascular Abnormalities and Brain Lesions (CABL) study. Participants were divided into 4 categories based on the severity and extent of AVC: 1) none or mild focal AVC; 2) mild diffuse AVC; 3) moderate-severe focal AVC; and 4) moderate-severe diffuse AVC. Central blood pressures and pulse pressure, total arterial compliance, augmentation index, and time to wave reflection were assessed using applanation tonometry. Results Indicators of arterial stiffness and wave reflection were significantly associated with AVC severity, except for central systolic and diastolic pressures and time to reflection. After adjustment for pertinent covariates (age, sex, race/ethnicity, and eGFR), only augmentation pressure (P = .02) and augmentation index (P = .002) were associated with the severity of AVC. Multivariable logistic regression analysis revealed that augmentation pressure (odds ratio per mmHg = 1.14; 95% confidence interval, 1.02–1.27; P = .02) and augmentation index (odds ratio per percentage point = 1.07; 95% confidence interval, 1.01–1.13; P = .02) were associated with an increase risk of moderate-severe diffuse AVC, even when central blood pressure value was included in the same model. Conclusions Arterial wave reflection is associated with AVC severity, independent of blood pressure values. Increased contribution of wave reflection to central blood pressure could be involved in the process leading to AVC. PMID:25600036

  10. Gas-induced friction and diffusion of rigid rotors

    NASA Astrophysics Data System (ADS)

    Martinetz, Lukas; Hornberger, Klaus; Stickler, Benjamin A.

    2018-05-01

    We derive the Boltzmann equation for the rotranslational dynamics of an arbitrary convex rigid body in a rarefied gas. It yields as a limiting case the Fokker-Planck equation accounting for friction, diffusion, and nonconservative drift forces and torques. We provide the rotranslational friction and diffusion tensors for specular and diffuse reflection off particles with spherical, cylindrical, and cuboidal shape, and show that the theory describes thermalization, photophoresis, and the inverse Magnus effect in the free molecular regime.

  11. Bounded fractional diffusion in geological media: Definition and Lagrangian approximation

    NASA Astrophysics Data System (ADS)

    Zhang, Yong; Green, Christopher T.; LaBolle, Eric M.; Neupauer, Roseanna M.; Sun, HongGuang

    2016-11-01

    Spatiotemporal fractional-derivative models (FDMs) have been increasingly used to simulate non-Fickian diffusion, but methods have not been available to define boundary conditions for FDMs in bounded domains. This study defines boundary conditions and then develops a Lagrangian solver to approximate bounded, one-dimensional fractional diffusion. Both the zero-value and nonzero-value Dirichlet, Neumann, and mixed Robin boundary conditions are defined, where the sign of Riemann-Liouville fractional derivative (capturing nonzero-value spatial-nonlocal boundary conditions with directional superdiffusion) remains consistent with the sign of the fractional-diffusive flux term in the FDMs. New Lagrangian schemes are then proposed to track solute particles moving in bounded domains, where the solutions are checked against analytical or Eulerian solutions available for simplified FDMs. Numerical experiments show that the particle-tracking algorithm for non-Fickian diffusion differs from Fickian diffusion in relocating the particle position around the reflective boundary, likely due to the nonlocal and nonsymmetric fractional diffusion. For a nonzero-value Neumann or Robin boundary, a source cell with a reflective face can be applied to define the release rate of random-walking particles at the specified flux boundary. Mathematical definitions of physically meaningful nonlocal boundaries combined with bounded Lagrangian solvers in this study may provide the only viable techniques at present to quantify the impact of boundaries on anomalous diffusion, expanding the applicability of FDMs from infinite domains to those with any size and boundary conditions.

  12. Patients' and caregivers' beliefs about depression screening and referral in the emergency department.

    PubMed

    Pailler, Megan E; Cronholm, Peter F; Barg, Frances K; Wintersteen, Matthew B; Diamond, Guy S; Fein, Joel A

    2009-11-01

    To explore patients' and parents'/caregivers' beliefs about the acceptability of universal depression screening in the emergency department (ED) and their perceptions of the barriers and facilitators to a mental health referral following a positive screen. We conducted semistructured interviews with 60 patients seeking care and 59 caregivers in the ED of an urban children's hospital. Interviews were audiotaped, transcribed, coded, and entered into N6 (version 6.0; QSR, Thousand Oaks, Calif) for coding and content analysis. Patients and caregivers supported the idea of depression screening in the ED, generally viewing screening as a reflection of care and concern. Respondents reported apprehension about stigma, privacy, and provider sensitivity. Introducing the screening concept early in the visit and as part of routine care was believed to reduce stigma. Respondents generally indicated that although they would likely follow through with a referral if given, stigma and denial were viewed as significant barriers. Caregivers also reported that logistical problems such as transportation, insurance, and agency hours created barriers to help seeking, but this could be offset by social supports and information about the agency and the provider. Patients and caregivers generally support depression screening in the pediatric ED but identified several barriers to screening and referral for treatment. Recommendations include introduction of universal screening early in the ED visit, provision of specific information about the meaning of screening results, and support from family and health care providers to help reduce stigma and increase referral acceptability.

  13. Differences in the Detection of BrdU/EdU Incorporation Assays Alter the Calculation for G1, S, and G2 Phases of the Cell Cycle in Trypanosomatids.

    PubMed

    da Silva, Marcelo Santos; Muñoz, Paula Andrea Marin; Armelin, Hugo Aguirre; Elias, Maria Carolina

    2017-11-01

    Trypanosomatids are the etiologic agents of various infectious diseases in humans. They diverged early during eukaryotic evolution and have attracted attention as peculiar models for evolutionary and comparative studies. Here, we show a meticulous study comparing the incorporation and detection of the thymidine analogs BrdU and EdU in Leishmania amazonensis, Trypanosoma brucei, and Trypanosoma cruzi to monitor their DNA replication. We used BrdU- and EdU-incorporated parasites with the respective standard detection approaches: indirect immunofluorescence to detect BrdU after standard denaturation (2 M HCl) and "click" chemistry to detect EdU. We found a discrepancy between these two thymidine analogs due to the poor detection of BrdU, which is reflected on the estimative of the duration of the cell cycle phases G1, S, and G2. To solve this discrepancy, we increase the exposure of incorporated BrdU using different concentrations of HCl. Using a new value for HCl concentration, we re-estimated the phases G1, S, G2 + M, and cytokinesis durations, confirming the values found by this approach using EdU. In conclusion, we suggest that the studies using BrdU with standard detection approach, not only in trypanosomatids but also in others cell types, should be reviewed to ensure an accurate estimation of DNA replication monitoring. © 2017 The Author(s) Journal of Eukaryotic Microbiology © 2017 International Society of Protistologists.

  14. Postural analysis in time and frequency domains in patients with Ehlers-Danlos syndrome.

    PubMed

    Galli, Manuela; Rigoldi, Chiara; Celletti, Claudia; Mainardi, Luca; Tenore, Nunzio; Albertini, Giorgio; Camerota, Filippo

    2011-01-01

    The goal of this work is to analyze postural control in Ehlers-Danlos syndrome (EDS) participants in time and frequency domain. This study considered a pathological group composed by 22 EDS participants performing a postural test consisting in maintaining standing position over a force platform for 30s in two conditions: open eyes (OE) and closed eyes (CE). In order to compare pathological group we acquired in the same conditions a control group composed by 20 healthy participants. The obtained center of pressure (COP) signal was analyzed in time and frequency domain using an AR model. Results revealed differences between pathological and control group: EDS participants pointed out difficulties in controlling COP displacements trying to keep it inside the BOS in AP direction and for this reason increased the use of ML mechanism in order to avoid the risk of fall. Also in CE conditions they demonstrated more difficulties in maintaining posture revealing the proprioceptive system is impaired, due to ligament laxity that characterized EDS participants. Frequency domain analysis showed no differences between the two groups, affirming that the changes in time domain reflected really the impairment to the postural control mechanism and not a different strategy assumed by EDS participants. These data could help in decision-making process to establish a correct rehabilitation approach, based on the reinforcing of muscle tone to supply the ligament laxity in order to prevent risks of falls and its consequences. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. Emergency department visits and primary care among adults with chronic conditions.

    PubMed

    McCusker, Jane; Roberge, Danièle; Lévesque, Jean-Frédéric; Ciampi, Antonio; Vadeboncoeur, Alain; Larouche, Danielle; Sanche, Steven

    2010-11-01

    An emergency department (ED) visit may be a marker for limited access to primary medical care, particularly among those with ambulatory care sensitive chronic conditions (ACSCC). In a population with universal health insurance, to examine the relationships between primary care characteristics and location of last general physician (GP) contact (in an ED vs. elsewhere) among those with and without an ACSCC. A cross-sectional survey using data from 2 cycles of the Canadian Community Health Survey carried out in 2003 and 2005. The study sample comprised Québec residents aged ≥18 who reported at least one GP contact during the previous 12 months, and were not hospitalized (n = 33,491). The primary outcome was place of last GP contact: in an ED versus elsewhere. Independent variables included the following: lack of a regular physician, perceived unmet healthcare needs, perceived availability of health care, number of contacts with doctors and nurses, and diagnosis of an ACSCC (hypertension, heart disease, chronic respiratory disease, diabetes). Using multiple logistic regression, with adjustment for sociodemographic, health status, and health services variables, lack of a regular GP and perceptions of unmet needs were associated with last GP contact in an ED; there was no interaction with ACSCC or other chronic conditions. Primary care characteristics associated with GP contact in an ED rather than another site reflect individual characteristics (affiliation with a primary GP and perceived needs) rather than the geographic availability of healthcare, both among those with and without chronic conditions.

  16. Bidirectional reflectance distribution function of diffuse extreme ultraviolet scatterers and extreme ultraviolet baffle materials.

    PubMed

    Newell, M P; Keski-Kuha, R A

    1997-08-01

    Bidirectional reflectance distribution function (BRDF) measurements of a number of diffuse extreme ultraviolet (EUV) scatterers and EUV baffle materials have been performed with the Goddard EUV scatterometer. BRDF data are presented for white Spectralon SRS-99 at 121.6 nm; the data exhibit a non-Lambertian nature and a total hemispherical reflectance lower than 0.15. Data are also presented for an evaporated Cu black sample, a black Spectralon SRS-02 sample, and a Martin Optical Black sample at wavelengths of 58.4 and 121.6 nm and for angles of incidence of 15 degrees and 45 degrees. Overall Martin Optical Black exhibited the lowest BRDF characteristic, with a total hemispherical reflectance of the order of 0.01 and measured BRDF values as low as 2 x 10(-3) sr(-1).

  17. Portable, Fiber-Based, Diffuse Reflection Spectroscopy (DRS) Systems for Estimating Tissue Optical Properties.

    PubMed

    Vishwanath, Karthik; Chang, Kevin; Klein, Daniel; Deng, Yu Feng; Chang, Vivide; Phelps, Janelle E; Ramanujam, Nimmi

    2011-02-01

    Steady-state diffuse reflection spectroscopy is a well-studied optical technique that can provide a noninvasive and quantitative method for characterizing the absorption and scattering properties of biological tissues. Here, we compare three fiber-based diffuse reflection spectroscopy systems that were assembled to create a light-weight, portable, and robust optical spectrometer that could be easily translated for repeated and reliable use in mobile settings. The three systems were built using a broadband light source and a compact, commercially available spectrograph. We tested two different light sources and two spectrographs (manufactured by two different vendors). The assembled systems were characterized by their signal-to-noise ratios, the source-intensity drifts, and detector linearity. We quantified the performance of these instruments in extracting optical properties from diffuse reflectance spectra in tissue-mimicking liquid phantoms with well-controlled optical absorption and scattering coefficients. We show that all assembled systems were able to extract the optical absorption and scattering properties with errors less than 10%, while providing greater than ten-fold decrease in footprint and cost (relative to a previously well-characterized and widely used commercial system). Finally, we demonstrate the use of these small systems to measure optical biomarkers in vivo in a small-animal model cancer therapy study. We show that optical measurements from the simple portable system provide estimates of tumor oxygen saturation similar to those detected using the commercial system in murine tumor models of head and neck cancer.

  18. Specular Reflection from Rough Surfaces Revisited

    ERIC Educational Resources Information Center

    Yasuda, Kensei; Kim, Alvin; Cho, Hayley; Timofejev, Timofej; Walecki, Wojciech J.; Klep, James; Edelson, Amy S.; Walecki, Abigail S.; Walecki, Eve S.; Walecki, Peter S.

    2016-01-01

    In his beautiful paper, Hasan Fakhruddin reported observations of mirror-like reflections in the rough surface of a ground glass plate. Similar effects have been recently employed for metrology of the roughness of optical diffusers used in modern light emitting device illumination systems. We report the observations of specular reflection in…

  19. The contribution of the diffuse light component to the topographic effect on remotely sensed data

    NASA Technical Reports Server (NTRS)

    Justice, C.; Holben, B.

    1980-01-01

    The topographic effect is measured by the difference between the global radiance from inclined surfaces as a function of their orientation relative to the sensor position and light source. The short wave radiant energy incident on a surface is composed of direct sunlight, scattered skylight, and light reflected from surrounding terrain. The latter two components are commonly known as the diffuse component. The contribution of the diffuse light component to the topographic effect was examined and the significance of this diffuse component with respect to two direct radiance models was assessed. Diffuse and global spectral radiances were measured for a series of slopes and aspects of a uniform and surface in the red and photographic infrared parts of the spectrum, using a nadir pointing two channel handheld radiometer. The diffuse light was found to produce a topographic effect which varied from the topographic effect for direct light. The topographic effect caused by diffuse light was found to increase slightly with solar elevation and wavelength for the channels examined. The correlations between data derived from two simple direct radiance simulation models and the field data were not significantly affected when the diffuse component was removed from the radiances. Radiances from a 60 percent reflective surface, assuming no atmospheric path radiance, the diffuse light topographic effect contributed a maximum range of 3 pixel values in simulated LANDSAT data from all aspects with slopes up to 30 degrees.

  20. Bounded fractional diffusion in geological media: Definition and Lagrangian approximation

    USGS Publications Warehouse

    Zhang, Yong; Green, Christopher T.; LaBolle, Eric M.; Neupauer, Roseanna M.; Sun, HongGuang

    2016-01-01

    Spatiotemporal Fractional-Derivative Models (FDMs) have been increasingly used to simulate non-Fickian diffusion, but methods have not been available to define boundary conditions for FDMs in bounded domains. This study defines boundary conditions and then develops a Lagrangian solver to approximate bounded, one-dimensional fractional diffusion. Both the zero-value and non-zero-value Dirichlet, Neumann, and mixed Robin boundary conditions are defined, where the sign of Riemann-Liouville fractional derivative (capturing non-zero-value spatial-nonlocal boundary conditions with directional super-diffusion) remains consistent with the sign of the fractional-diffusive flux term in the FDMs. New Lagrangian schemes are then proposed to track solute particles moving in bounded domains, where the solutions are checked against analytical or Eularian solutions available for simplified FDMs. Numerical experiments show that the particle-tracking algorithm for non-Fickian diffusion differs from Fickian diffusion in relocating the particle position around the reflective boundary, likely due to the non-local and non-symmetric fractional diffusion. For a non-zero-value Neumann or Robin boundary, a source cell with a reflective face can be applied to define the release rate of random-walking particles at the specified flux boundary. Mathematical definitions of physically meaningful nonlocal boundaries combined with bounded Lagrangian solvers in this study may provide the only viable techniques at present to quantify the impact of boundaries on anomalous diffusion, expanding the applicability of FDMs from infinite do mains to those with any size and boundary conditions.

  1. Channels That Cooperatively Service a Data Stream and Voice Messages. II. Diffusion Approximations.

    DTIC Science & Technology

    1979-11-01

    Leoczky, Profegsr J 2 ’ "-Carnegie-Mellon University D -1 " Gaver, Professor Department of Operations Research Reviewed by: Released by: Michael G...ered) REPORT DOCUMENTATION PAGE BFRE CNSTRUTINOR ~I4 REPORT-9Nu 2 . GOVT ACCESSION No. 3 RECIPIENT’S CATALOG NUMBER 4TITLE (and Sbtile) TPOFP0 ED...approximations valid for the extreme but realistic case in which n/p is large, and none give a Wiener approximation. 2 Rather than focus on this simple

  2. Differentiating pediatric epileptic brain tissue from normal brain tissue by using time-dependent diffuse reflectance spectroscopy in vivo: comprehensive data analysis method in the time domain

    NASA Astrophysics Data System (ADS)

    Oh, Sanghoon; Fernald, Bradley; Bhatia, Sanjiv; Ragheb, John; Sandberg, David; Johnson, Mahlon; Lin, Wei-Chiang

    2009-05-01

    This research investigated the feasibility of using time-dependent diffuse reflectance spectroscopy to differentiate pediatric epileptic brain tissue from normal brain tissue. The optical spectroscopic technique monitored the dynamic optical properties of the cerebral cortex that are associated with its physiological, morphological, and compositional characteristics. Due to the transient irregular epileptic discharge activity within the epileptic brain tissue it was hypothesized that the lesion would express abnormal dynamic optical behavior that would alter normal dynamic behavior. Thirteen pediatric epilepsy patients and seven pediatric brain tumor patients (normal controls) were recruited for this clinical study. Dynamic optical properties were obtained from the cortical surface intraoperatively using a timedependent diffuse reflectance spectroscopy system. This system consisted of a fiber-optic probe, a tungsten-halogen light source, and a spectrophotometer. It acquired diffuse reflectance spectra with a spectral range of 204 nm to 932 nm at a rate of 33 spectra per second for approximately 12 seconds. Biopsy samples were taken from electrophysiologically abnormal cortex and evaluated by a neuropathologist, which served as a gold standard for lesion classification. For data analysis, spectral intensity changes of diffuse reflectance in the time domain at two different wavelengths from each investigated site were compared. Negative correlation segment, defined by the periods where the intensity changes at the two wavelengths were opposite in their slope polarity, were extracted. The total duration of negative correlation, referred to as the "negative correlation time index", was calculated by integrating the negative correlation segments. The negative correlation time indices from all investigated sites were sub-grouped according to the corresponding histological classifications. The difference between the mean indices of two subgroups was evaluated by standard t-test. These comparison and calculation procedures were carried out for all possible wavelength combinations between 400 nm and 800 nm with 2 nm increments. The positive group consisted of seven pathologically abnormal test sites, and the negative group consisted of 13 normal test sites from non-epileptic tumor patients. A standard t-test showed significant difference between negative correlation time indices from the two groups at the wavelength combinations of 700-760 nm versus 550-580 nm. An empirical discrimination algorithm based on the negative correlation time indices in this range produced 100% sensitivity and 85% specificity. Based on these results time-dependent diffuse reflectance spectroscopy with optimized data analysis methods differentiates epileptic brain tissue from normal brain tissue adequately, therefore can be utilized for surgical guidance, and may enhance the surgical outcome of pediatric epilepsy surgery.

  3. When high pressure, system constraints, and a social justice mission collide: A socio-structural analysis of emergency department social work services.

    PubMed

    Moore, Megan; Cristofalo, Margaret; Dotolo, Danae; Torres, Nicole; Lahdya, Alexandra; Ho, Leyna; Vogel, Mia; Forrester, Mollie; Conley, Bonnie; Fouts, Susan

    2017-04-01

    The emergency department (ED) can be a critical intervention point for many patients with multifaceted needs. Social workers have long been part of interdisciplinary ED teams. This study aimed to contribute to the limited understanding of social worker-patient interactions and factors influencing social work services in this setting. This paper reports a qualitative content analysis of social work medical record notes (N = 1509) of services provided to trauma patients in an urban, public, level 1 trauma center and an in-depth analysis of semi-structured interviews with ED social workers (N = 10). Eight major social work roles were identified: investigator, gatekeeper, resource broker, care coordinator, problem solver, crisis manager, advocate, discharge planner. Analyses revealed a complex interplay between ED social work services and multi-layered contexts. Using a social-ecological framework, we identified the interactions between micro or individual level factors, mezzo or local system level factors and macro environmental and systemic factors that play a role in ED interactions and patient services. Macro-level contextual influences were socio-structural forces including socioeconomic barriers to health, social hierarchies that reflected power differentials between providers and patients, and distrust or bias. Mezzo-level forces were limited resources, lack of healthcare system coordination, a challenging hierarchy within the medical model and the pressure to discharge patients quickly. Micro-level factors included characteristics of patients and social workers, complexity of patient stressors, empathic strain, lack of closure and compassion. All of these forces were at play in patient-social worker interactions and impacted service provision. Social workers were at times able to successfully navigate these forces, yet at other times these challenges were insurmountable. A conceptual model of ED social work and the influences on the patient-social worker interactions was developed to assist in guiding innovative research and practice models to improve services and outcomes in the complex, fast-paced ED. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. When high pressure, system constraints, and a social justice mission collide: a socio-structural analysis of emergency department social work services

    PubMed Central

    Cristofalo, Margaret; Dotolo, Danae; Torres, Nicole; Lahdya, Alexandra; Ho, Leyna; Vogel, Mia; Forrester, Mollie; Conley, Bonnie; Fouts, Susan

    2017-01-01

    The emergency department (ED) can be a critical intervention point for many patients with multifaceted needs. Social workers have long been part of interdisciplinary ED teams. This study aimed to contribute to the limited understanding of social worker-patient interactions and factors influencing social work services in this setting. This paper reports a qualitative content analysis of social work medical record notes (N=1,509) of services provided to trauma patients in an urban, public, level 1 trauma center and an in-depth analysis of semi-structured interviews with ED social workers (N=10). Eight major social work roles were identified: investigator, gatekeeper, resource broker, care coordinator, problem solver, crisis manager, advocate, discharge planner. Analyses revealed a complex interplay between ED social work services and multi-layered contexts. Using a social-ecological framework, we identified the interactions between micro or individual level factors, mezzo or local system level factors and macro environmental and systemic factors that play a role in ED interactions and patient services. Macro-level contextual influences were socio-structural forces including socioeconomic barriers to health, social hierarchies that reflected power differentials between providers and patients, and distrust or bias. Mezzo-level forces were limited resources, lack of healthcare system coordination, a challenging hierarchy within the medical model and the pressure to discharge patients quickly. Micro-level factors included characteristics of patients and social workers, complexity of patient stressors, empathic strain, lack of closure and compassion. All of these forces were at play in patient-social worker interactions and impacted service provision. Social workers were at times able to successfully navigate these forces, yet at other times these challenges were insurmountable. A conceptual model of ED social work and the influences on the patient-social worker interactions was developed to assist in guiding innovative research and practice models to improve services and outcomes in the complex, fast-paced ED. PMID:28214722

  5. Inaccurate Ascertainment of Morbidity and Mortality due to Influenza in Administrative Databases: A Population-Based Record Linkage Study

    PubMed Central

    Muscatello, David J.; Amin, Janaki; MacIntyre, C. Raina; Newall, Anthony T.; Rawlinson, William D.; Sintchenko, Vitali; Gilmour, Robin; Thackway, Sarah

    2014-01-01

    Background Historically, counting influenza recorded in administrative health outcome databases has been considered insufficient to estimate influenza attributable morbidity and mortality in populations. We used database record linkage to evaluate whether modern databases have similar limitations. Methods Person-level records were linked across databases of laboratory notified influenza, emergency department (ED) presentations, hospital admissions and death registrations, from the population (∼6.9 million) of New South Wales (NSW), Australia, 2005 to 2008. Results There were 2568 virologically diagnosed influenza infections notified. Among those, 25% of 40 who died, 49% of 1451 with a hospital admission and 7% of 1742 with an ED presentation had influenza recorded on the respective database record. Compared with persons aged ≥65 years and residents of regional and remote areas, respectively, children and residents of major cities were more likely to have influenza coded on their admission record. Compared with older persons and admitted patients, respectively, working age persons and non-admitted persons were more likely to have influenza coded on their ED record. On both ED and admission records, persons with influenza type A infection were more likely than those with type B infection to have influenza coded. Among death registrations, hospital admissions and ED presentations with influenza recorded as a cause of illness, 15%, 28% and 1.4%, respectively, also had laboratory notified influenza. Time trends in counts of influenza recorded on the ED, admission and death databases reflected the trend in counts of virologically diagnosed influenza. Conclusions A minority of the death, hospital admission and ED records for persons with a virologically diagnosed influenza infection identified influenza as a cause of illness. Few database records with influenza recorded as a cause had laboratory confirmation. The databases have limited value for estimating incidence of influenza outcomes, but can be used for monitoring variation in incidence over time. PMID:24875306

  6. Meeting report: international workshop on endocrine disruptors: exposure and potential impact on consumers health.

    PubMed

    Rousselle, C; Ormsby, J N; Schaefer, B; Lampen, A; Platzek, T; Hirsch-Ernst, K; Warholm, M; Oskarsson, A; Nielsen, P J; Holmer, M L; Emond, C

    2013-02-01

    The French Agency for Food, Environmental and Occupational Health and Safety (Anses) hosted a two-day workshop on Endocrine Disruptors: Exposure and Potential Impact on Consumers Health, bringing together participants from international organizations, academia, research institutes and from German, Swedish, Danish and French governmental agencies. The main objective of the workshop was to share knowledge and experiences on endocrine disruptors (ED) exposure and potential impact on consumers' health, to identify current risk assessment practices and knowledge gaps and issue recommendations on research needs and future collaboration. The following topics were reviewed: (1) Definition of ED, (2) endpoints to be considered for Risk assessment (RA) of ED, (3) non-monotonic dose response curves, (4) studies to be considered for RA (regulatory versus academic studies), (5) point of departure and uncertainty factors, (6) exposure assessment, (7) regulatory issues related to ED. The opinions expressed during this workshop reflect day-to-day experiences from scientists, regulators, researchers, and others from many different countries in the fields of risk assessment, and were regarded by the attendees as an important basis for further discussions. Accordingly, the participants underlined the need for more exchange in the future to share experiences and improve the methodology related to risk assessment for endocrine disrupters. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Sex-related Differences in Emergency Department Renal Colic Management: Females Have Fewer Computed Tomography Scans but Similar Outcomes.

    PubMed

    Innes, Grant D; Scheuermeyer, Frank X; Law, Michael R; McRae, Andrew D; Weber, Bryce A; Boyda, Heidi N; Lonergan, Kevin; Andruchow, James E

    2016-10-01

    Sex-related differences occur in many areas of medicine. Emergency department (ED) studies have suggested differences in access to care, diagnostic imaging use, pain management, and intervention. We investigated sex-based differences in the care and outcomes for ED patients with acute renal colic. This was a multicenter population-based retrospective observational cohort study using administrative data and supplemented by structured chart review. All patients seen in Calgary Health Region EDs between January 1 and December 31, 2014, with an ED diagnosis of renal colic based on the following ICD-10 codes were eligible for inclusion: calculus of kidney (N200), calculus of ureter (N201), calculus of kidney with calculus of ureter (N202), hydronephrosis with renal and ureteral calculous obstruction (N132), unspecified renal colic (N23), and unspecified urinary calculus (N209). ED visit data and test results were accessed in the regional ED clinical database. Stone characteristics were captured from diagnostic imaging reports. Regional hospital databases were used to identify subsequent ED encounters, hospital admissions, and surgical procedures within 60 days. Outcomes were stratified by sex. The primary outcome, intended as a marker of overall effectiveness of ED care, was the unscheduled 7-day ED revisit rate among patients who were discharged home after their index ED visit. Secondary outcomes included ED pain management as reflected by administration of narcotics or intravenous nonsteroidals, the performance of advanced imaging-either ultrasound (US) or computed tomography (CT), and the proportion of patients who required hospitalization or surgical intervention within 60 days. From January 1 to December 31, 2014, a total of 3,104 eligible patients were studied: 1,111 women (35.8%) and 1,993 men (64.2%). Baseline characteristics, access times, analgesic use, and admission rates were similar in both groups. Men were more likely to have CT (68.9% vs. 58.5%, difference = 10.4%, 95% confidence interval [CI] = 6.8 to 14.0) while women were more likely to have US (20.8% vs. 9.6%, difference = 11.2%, 95% CI = 8.4 to 13.9). At 7 days, 17.9% of women and 19.0% of men who were discharged after their index ED visit required an ED revisit (difference = 1.1%, 95% CI = -2.8 to 4.9). Men were more likely to be hospitalized at 7 days (9.8% vs. 6.5%, difference = 3.3%, 95% CI = 0.6 to 6.0). This study shows greater reliance on US in females but no other sex-specific differences in the management of ED patients with acute renal colic. Higher CT use in men was not associated with improved outcomes, and we found no important differences in access to care, diagnostic or treatment intensity, or revisit rates as a marker of care effectiveness. © 2016 by the Society for Academic Emergency Medicine.

  8. Bidirectional Reflectance Round-Robin in Support of the Earth Observing System Program

    NASA Technical Reports Server (NTRS)

    Early, E.; Barnes, P.; Johnson, B.; Butler, J.; Bruegge, C.; Biggar, S.; Spyak, P.; Pavlov, M.

    1999-01-01

    Laboratory measurements of the bidirectional reflectance distribution function (BRDRF) of diffuse reflectors are required to support calibration in the Earth Observing System (EOS) program of the National Aeronautics and Space Administration.

  9. Improvement in self-reported confidence in nurses’ professional skills in the emergency department

    PubMed Central

    2013-01-01

    Background The aim of this study was to assess nurses’ self-reported confidence in their professional skills before and after an extensive Emergency Department (ED) reform in Kanta-Häme Central Hospital. Methods Emergency nurses participated in transitional training commencing two years before the establishment of the new organization in 2007. Training was followed by weekly practical educational sessions in the new ED. During this process nurses improved their transition skills, defined house rules for the new clinic and improved their knowledge of new technology and instruments. The main processes involving critically ill ED patients were described and modelled with an electronic flow chart software. During the transitional training nurses compiled lists of practical skills and measures needed in the ED. These were updated after feedback from physicians in primary and secondary care and head physicians in Kanta-Häme Central Hospital. The final 189-item list comprised 15 different categories, each containing from 4 to 35 items. Based on the work described above, a questionnaire was developed to reflect ED nurses’ skills in clinical measures but also to estimate the need for professional education and practical training. Nurses working in the ED were asked to fill the questionnaire in January 2007 (response rate 97%) and in January 2011 (response rate 98%). Results Nurses’ self-reported confidence in their professional skills improved significally in eight classes out of fifteen. These classes were cannulations, urinary catheterizations, patient monitoring, cardiac patients, equipment, triage and nurse practising, psychiatric patients as well as infection risk. Best results were noted in urinary catheterizations, patient monitoring and infection risk. When studying the group of nurses participating in both surveys in 2007 and 2011, improvements were observed in all fifteen categories. All but two of these changes were significant (p<0.05). Conclusions During an extensive reform of emergency services, we noted a significant improvement in the professional skills of nurses. This improvement was especially consistent among nurses working in the ED during the whole transition process. Nurses’ education and training program in the ED may be successfully put into practice when based on co-operation between nurses and physicians dedicated to emergency services. PMID:23497683

  10. Improvement in self-reported confidence in nurses' professional skills in the emergency department.

    PubMed

    Rautava, Veli-Pekka; Palomäki, Erika; Innamaa, Tapio; Perttu, Mika; Lehto, Päivi; Palomäki, Ari

    2013-03-05

    The aim of this study was to assess nurses' self-reported confidence in their professional skills before and after an extensive Emergency Department (ED) reform in Kanta-Häme Central Hospital. Emergency nurses participated in transitional training commencing two years before the establishment of the new organization in 2007. Training was followed by weekly practical educational sessions in the new ED. During this process nurses improved their transition skills, defined house rules for the new clinic and improved their knowledge of new technology and instruments. The main processes involving critically ill ED patients were described and modelled with an electronic flow chart software.During the transitional training nurses compiled lists of practical skills and measures needed in the ED. These were updated after feedback from physicians in primary and secondary care and head physicians in Kanta-Häme Central Hospital. The final 189-item list comprised 15 different categories, each containing from 4 to 35 items. Based on the work described above, a questionnaire was developed to reflect ED nurses' skills in clinical measures but also to estimate the need for professional education and practical training. Nurses working in the ED were asked to fill the questionnaire in January 2007 (response rate 97%) and in January 2011 (response rate 98%). Nurses' self-reported confidence in their professional skills improved significally in eight classes out of fifteen. These classes were cannulations, urinary catheterizations, patient monitoring, cardiac patients, equipment, triage and nurse practising, psychiatric patients as well as infection risk. Best results were noted in urinary catheterizations, patient monitoring and infection risk. When studying the group of nurses participating in both surveys in 2007 and 2011, improvements were observed in all fifteen categories. All but two of these changes were significant (p<0.05). During an extensive reform of emergency services, we noted a significant improvement in the professional skills of nurses. This improvement was especially consistent among nurses working in the ED during the whole transition process. Nurses' education and training program in the ED may be successfully put into practice when based on co-operation between nurses and physicians dedicated to emergency services.

  11. Use of Spectralon as a diffuse reflectance standard for in-flight calibration of earth-orbiting sensors

    NASA Technical Reports Server (NTRS)

    Bruegge, Carol J.; Stiegman, Albert E.; Rainen, Richard A.; Springsteen, Arthur W.

    1993-01-01

    Spectralon, a commercially available diffuse reflectance material made from polytetrafluoroethylene (PTFE), is being evaluated for the multiangle imaging spectroradiometer (MISR), currently under development for the Earth Observing System. Results of a series of environmental exposure tests indicate that no degradation of the optical properties was apparent following proton bombardment, and stability through UV illumination was satisfactory, provided simple cleaning and handling procedures were implemented. A buildup of several thousand volts of static charge was found to develop while simulating a rare pass through an auroral storm.

  12. Critical comparison of diffuse reflectance spectroscopy and colorimetry as dermatological diagnostic tools for acanthosis nigricans: a chemometric approach.

    PubMed

    Devpura, Suneetha; Pattamadilok, Bensachee; Syed, Zain U; Vemulapalli, Pranita; Henderson, Marsha; Rehse, Steven J; Hamzavi, Iltefat; Lim, Henry W; Naik, Ratna

    2011-06-01

    Quantification of skin changes due to acanthosis nigricans (AN), a disorder common among insulin-resistant diabetic and obese individuals, was investigated using two optical techniques: diffuse reflectance spectroscopy (DRS) and colorimetry. Measurements were obtained from AN lesions on the neck and two control sites of eight AN patients. A principal component/discriminant function analysis successfully differentiated between AN lesion and normal skin with 87.7% sensitivity and 94.8% specificity in DRS measurements and 97.2% sensitivity and 96.4% specificity in colorimetry measurements.

  13. Deterioration of reflecting coatings by intermetallic diffusion.

    PubMed

    Hunter, W R; Mikes, T L; Hass, G

    1972-07-01

    Gold diffraction gratings overcoated with Al + MgF(2) to increase their efficiency in the vacuum ultraviolet suffered a severe loss in efficiency within six months to a year after coating; for example, from 50% to 2% at lambda1216 A. The cause of this loss was assumed to be interdiffusion of Au and Al; therefore, a more complete study of Au-Al film combinations was performed. The coatings were aged at room and elevated temperatures. Reflectance measurements were made in the visible and vacuum ultraviolet spectral regions. For wavelengths longer than lambda900 A, the measurements show very little change until the diffusion boundary reaches the penetration depth of the radiation. If Al is the first surface layer, however, reflectance measurements at lambda584 A permit measuring the progress of the diffusion boundary toward the Al surface because of the low absorptance of Al at this wavelength. Interdiffusion can be effectively eliminated by the use of thin dielectric layers uch as SiO and the natural oxide of Al. Such protected coatings have been exposed for one week at a temperature of 170 degrees C with no visible sign of diffusion, whereas a similar coating without the barrier layer would become useless in less than 1 h. Some preliminary studies have been made with Pt-Al film combinations.

  14. Robust estimation of cerebral hemodynamics in neonates using multilayered diffusion model for normal and oblique incidences

    NASA Astrophysics Data System (ADS)

    Steinberg, Idan; Harbater, Osnat; Gannot, Israel

    2014-07-01

    The diffusion approximation is useful for many optical diagnostics modalities, such as near-infrared spectroscopy. However, the simple normal incidence, semi-infinite layer model may prove lacking in estimation of deep-tissue optical properties such as required for monitoring cerebral hemodynamics, especially in neonates. To answer this need, we present an analytical multilayered, oblique incidence diffusion model. Initially, the model equations are derived in vector-matrix form to facilitate fast and simple computation. Then, the spatiotemporal reflectance predicted by the model for a complex neonate head is compared with time-resolved Monte Carlo (TRMC) simulations under a wide range of physiologically feasible parameters. The high accuracy of the multilayer model is demonstrated in that the deviation from TRMC simulations is only a few percent even under the toughest conditions. We then turn to solve the inverse problem and estimate the oxygen saturation of deep brain tissues based on the temporal and spatial behaviors of the reflectance. Results indicate that temporal features of the reflectance are more sensitive to deep-layer optical parameters. The accuracy of estimation is shown to be more accurate and robust than the commonly used single-layer diffusion model. Finally, the limitations of such approaches are discussed thoroughly.

  15. Higher Ed. Gets Voting Rights on Assessments

    ERIC Educational Resources Information Center

    Gewertz, Catherine

    2012-01-01

    A group of states that is designing tests for the common academic standards has taken a key step to ensure that the assessments reflect students' readiness for college-level work: It gave top higher education officials from member states voting power on test-design questions that are closest to the heart of the college-readiness question. At its…

  16. Mobile Knowledge, Karma Points and Digital Peers: The Tacit Epistemology and Linguistic Representation of MOOCs

    ERIC Educational Resources Information Center

    Portmess, Lisa

    2013-01-01

    Media representations of massive open online courses (MOOCs) such as those offered by Coursera, edX and Udacity reflect tension and ambiguity in their bold promise of democratized education and global knowledge sharing. An approach to MOOCs that emphasizes the tacit epistemology of such representations suggests a richer account of the ambiguities…

  17. Sustainability from the Transdisciplinary Perspective: An Action Research Strategy for Continuing Education Program Development

    ERIC Educational Resources Information Center

    Salite, lga; Drelinga, Elga; Iliško, Dzintra; Olehnovica, Eridiana; Zarina, Sandra

    2016-01-01

    The need to focus on a transdisciplinary approach in education for sustainable development (EDS) has been reflected in research and especially action research as a possible solution, which can open a new perspective for understanding and interpretation of the complex phenomenon of sustainability as well as for developing new open continuing…

  18. A Profile on Emergency Department Utilization in Adolescents and Young Adults with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Liu, Guodong; Pearl, Amanda M.; Kong, Lan; Leslie, Douglas L.; Murray, Michael J.

    2017-01-01

    There has been an increase in utilization of the Emergency Department (ED) in individuals with autism spectrum disorder (ASD) which may reflect a deficit of services (Green et al., "Journal of the American Academy of Child and Adolescent Psychiatry" 40(3):325-332, 2001; Gurney et al., "Archives of Pediatric and Adolescent…

  19. Gender/ed Discourses and Emotional Sub-Texts: Theorising Emotion in UK Higher Education

    ERIC Educational Resources Information Center

    Leathwood, Carole; Hey, Valerie

    2009-01-01

    This article engages with contemporary debates about the absence/presence of emotion in higher education. UK higher education has traditionally been constructed as an emotion-free zone, reflecting the dominance of Cartesian dualism with its rational/emotional, mind/body, male/female split. This construction has been challenged in recent years by…

  20. Students' Performance in M. Ed. Programs at the Cleveland State University, 1968-1975.

    ERIC Educational Resources Information Center

    Gans, Thomas G.

    The College of Education of the Cleveland State University opened its first graduate program in 1968. The purpose of the study reported here is to provide information for reflection about the college's past performance and for planning new directions in its graduate programs. The study uses information from college and university records,…

  1. Mississippi Curriculum Framework for Family and Consumer Sciences and Related Technology (Enrichment) (CIP: 20.0101--Comprehensive Consumer & Homemkg. Ed.). Secondary Programs.

    ERIC Educational Resources Information Center

    Mississippi Research and Curriculum Unit for Vocational and Technical Education, State College.

    This document, which reflects Mississippi's statutory requirement that instructional programs be based on core curricula and performance-based assessment, contains outlines of the instructional units required in local instructional management plans and daily lesson plans for family and consumer sciences and related technology (enrichment).…

  2. Addressing Social Difference with Prospective Teachers Who Want "To Make a Difference"

    ERIC Educational Resources Information Center

    Whitehead, Kay

    2007-01-01

    This paper focuses on a cohort of B.Ed. students' understandings about social difference and social justice as recorded in their professional journals in the first semester of third year. It shows that their reasons for choosing teaching as a career, reflections on their school experiences and discussions about future students are grounded in the…

  3. Design Rules for Tailoring Antireflection Properties of Hierarchical Optical Structures

    DOE PAGES

    Leon, Juan J. Diaz; Hiszpanski, Anna M.; Bond, Tiziana C.; ...

    2017-05-18

    Hierarchical structures consisting of small sub-wavelength features stacked atop larger structures have been demonstrated as an effective means of reducing the reflectance of surfaces. However, optical devices require different antireflective properties depending on the application, and general unifying guidelines on hierarchical structures' design to attain a desired antireflection spectral response are still lacking. The type of reflectivity (diffuse, specular, or total/hemispherical) and its angular- and spectral-dependence are all dictated by the structural parameters. Through computational and experimental studies, guidelines have been devised to modify these various aspects of reflectivity across the solar spectrum by proper selection of the features ofmore » hierarchical structures. In this wavelength regime, micrometer-scale substructures dictate the long-wavelength spectral response and effectively reduce specular reflectance, whereas nanometer-scale substructures dictate primarily the visible wavelength spectral response and reduce diffuse reflectance. Coupling structures having these two length scales into hierarchical arrays impressively reduces surfaces' hemispherical reflectance across a broad spectrum of wavelengths and angles. Furthermore, such hierarchical structures in silicon are demonstrated having an average total reflectance across the solar spectrum of 1.1% (average weighted reflectance of 1% in the 280–2500 nm range of the AM 1.5 G spectrum) and specular reflectance <1% even at angles of incidence as high as 67°.« less

  4. Why do veins appear blue? A new look at an old question

    NASA Astrophysics Data System (ADS)

    Kienle, Alwin; Hibst, Raimund; Steiner, Rudolf; Lilge, Lothar; Vitkin, I. Alex; Wilson, Brian C.; Patterson, Michael S.

    1996-03-01

    We investigate why vessels that contain blood, which has a red or a dark red color, may look bluish in human tissue. A CCD camera was used to make images of diffusely reflected light at different wavelengths. Measurements of reflectance that are due to model blood vessels in scattering media and of human skin containing a prominent vein are presented. Monte Carlo simulations were used to calculate the spatially resolved diffuse reflectance for both situations. We show that the color of blood vessels is scattering and absorption characteristics of skin at different wavelengths, (ii) the oxygenation state of blood, which affects its absorption properties, (iii) the diameter and the depth of the vessels, and (iv) the visual perception process.

  5. Bidirectional plant canopy reflection models derived from the radiation transfer equation

    NASA Technical Reports Server (NTRS)

    Beeth, D. R.

    1975-01-01

    A collection of bidirectional canopy reflection models was obtained from the solution of the radiation transfer equation for a horizontally homogeneous canopy. A phase function is derived for a collection of bidirectionally reflecting and transmitting planar elements characterized geometrically by slope and azimuth density functions. Two approaches to solving the radiation transfer equation for the canopy are presented. One approach factors the radiation transfer equation into a solvable set of three first-order linear differential equations by assuming that the radiation field within the canopy can be initially approximated by three components: uniformly diffuse downwelling, uniformly diffuse upwelling, and attenuated specular. The solution to these equations, which can be iterated to any degree of accuracy, was used to obtain overall canopy reflection from the formal solution to the radiation transfer equation. A programable solution to canopy overall bidirectional reflection is given for this approach. The special example of Lambertian leaves with constant leaf bidirectional reflection and scattering functions is considered, and a programmable solution for this example is given. The other approach to solving the radiation transfer equation, a generalized Chandrasekhar technique, is presented in the appendix.

  6. EFFECT OF Mg AND TEMPERATURE ON Fe-Al ALLOY LAYER IN Fe/(Zn-6%Al-x%Mg) SOLID-LIQUID DIFFUSION COUPLES

    NASA Astrophysics Data System (ADS)

    Liang, Liu; Liu, Ya-Ling; Liu, Ya; Peng, Hao-Ping; Wang, Jian-Hua; Su, Xu-Ping

    Fe/(Zn-6%Al-x%Mg) solid-liquid diffusion couples were kept at various temperatures for different periods of time to investigate the formation and growth of the Fe-Al alloy layer. Scanning electron microscopy (SEM), energy dispersive spectrometry (EDS) and X-ray diffraction (XRD) were used to study the constituents and morphology of the Fe-Al alloy layer. It was found that the Fe2Al5Znx phase layer forms close to the iron sheet and the FeAl3Znx phase layer forms near the side of the melted Zn-6%Al-3%Mg in diffusion couples. When the Fe/(Zn-6%Al-3%Mg) diffusion couple is kept at 510∘C for more than 15min, a continuous Fe-Al alloy layer is formed on the interface of the diffusion couple. Among all Fe/(Zn-6%Al-x%Mg) solid-liquid diffusion couples, the Fe-Al alloy layer on the interface of the Fe/(Zn-6% Al-3% Mg) diffusion couple is the thinnest. The Fe-Al alloy layer forms only when the diffusion temperature is above 475∘. These results show that the Fe-Al alloy layer in Fe/(Zn-6%Al-x%Mg) solid-liquid diffusion couples is composed of Fe2Al5Znx and FeAl3Znx phase layers. Increasing the diffusing temperature and time period would promote the formation and growth of the Fe-Al alloy layer. When the Mg content in the Fe/(Zn-6%Al-x%Mg) diffusion couples is 3%, the growth of the Fe-Al alloy layer is inhibited. These results may explain why there is no obvious Fe-Al alloy layer formed on the interface of steel with a Zn-6%Al-3%Mg coating.

  7. Determination of oxygen diffusion kinetics during thin film ruthenium oxidation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coloma Ribera, R., E-mail: r.colomaribera@utwente.nl; Kruijs, R. W. E. van de; Yakshin, A. E.

    2015-08-07

    In situ X-ray reflectivity was used to reveal oxygen diffusion kinetics for thermal oxidation of polycrystalline ruthenium thin films and accurate determination of activation energies for this process. Diffusion rates in nanometer thin RuO{sub 2} films were found to show Arrhenius behaviour. However, a gradual decrease in diffusion rates was observed with oxide growth, with the activation energy increasing from about 2.1 to 2.4 eV. Further exploration of the Arrhenius pre-exponential factor for diffusion process revealed that oxidation of polycrystalline ruthenium joins the class of materials that obey the Meyer-Neldel rule.

  8. Variable-order fractional MSD function to describe the evolution of protein lateral diffusion ability in cell membranes

    NASA Astrophysics Data System (ADS)

    Yin, Deshun; Qu, Pengfei

    2018-02-01

    Protein lateral diffusion is considered anomalous in the plasma membrane. And this diffusion is related to membrane microstructure. In order to better describe the property of protein lateral diffusion and find out the inner relationship between protein lateral diffusion and membrane microstructure, this article applies variable-order fractional mean square displacement (f-MSD) function for characterizing the anomalous diffusion. It is found that the variable order can reflect the evolution of diffusion ability. The results of numerical simulation demonstrate variable-order f-MSD function can predict the tendency of anomalous diffusion during the process of confined diffusion. It is also noted that protein lateral diffusion ability during the processes of confined and hop diffusion can be split into three parts. In addition, the comparative analyses reveal that the variable order is related to the confinement-domain size and microstructure of compartment boundary too.

  9. Understanding ethical dilemmas in the emergency department: views from medical students' essays.

    PubMed

    House, Joseph B; Theyyunni, Nikhil; Barnosky, Andrew R; Fuhrel-Forbis, Andrea; Seeyave, Desiree M; Ambs, Dawn; Fischer, Jonathan P; Santen, Sally A

    2015-04-01

    For medical students, the emergency department (ED) often presents ethical problems not encountered in other settings. In many medical schools there is little ethics training during the clinical years. The benefits of reflective essay writing in ethics and professionalism education are well established. The purpose of this study was to determine and categorize the types of ethical dilemmas and scenarios encountered by medical students in the ED through reflective essays. During a 4(th)-year emergency medicine rotation, all medical students wrote brief essays on an ethical situation encountered in the ED, and participated in an hour debriefing session about these essays. Qualitative analysis was performed to determine common themes from the essays. The frequency of themes was calculated. The research team coded 173 essays. The most common ethical themes were autonomy (41%), social justice (32.4%), nonmaleficence (31.8%), beneficence (26.6%), fidelity (12%), and respect (8.7%). Many of the essays contained multiple ethical principles that were often in conflict with each other. In one essay, a student grappled with the decision to intubate a patient despite a preexisting do-not-resuscitate order. This patient encounter was coded with autonomy, beneficence, and nonmaleficence. Common scenarios included ethical concerns when caring for critical patients, treatment of pain, homeless or alcoholic patients, access to care, resource utilization, and appropriateness of care. Medical students encounter patients with numerous ethically based issues. Frequently, they note conflicts between ethical principles. Such essays constitute an important resource for faculty, resident, and student ethics training. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Separation of specular and diffuse components using tensor voting in color images.

    PubMed

    Nguyen, Tam; Vo, Quang Nhat; Yang, Hyung-Jeong; Kim, Soo-Hyung; Lee, Guee-Sang

    2014-11-20

    Most methods for the detection and removal of specular reflections suffer from nonuniform highlight regions and/or nonconverged artifacts induced by discontinuities in the surface colors, especially when dealing with highly textured, multicolored images. In this paper, a novel noniterative and predefined constraint-free method based on tensor voting is proposed to detect and remove the highlight components of a single color image. The distribution of diffuse and specular pixels in the original image is determined using tensors' saliency analysis, instead of comparing color information among neighbor pixels. The achieved diffuse reflectance distribution is used to remove specularity components. The proposed method is evaluated quantitatively and qualitatively over a dataset of highly textured, multicolor images. The experimental results show that our result outperforms other state-of-the-art techniques.

  11. Translucent Radiosity: Efficiently Combining Diffuse Inter-Reflection and Subsurface Scattering.

    PubMed

    Sheng, Yu; Shi, Yulong; Wang, Lili; Narasimhan, Srinivasa G

    2014-07-01

    It is hard to efficiently model the light transport in scenes with translucent objects for interactive applications. The inter-reflection between objects and their environments and the subsurface scattering through the materials intertwine to produce visual effects like color bleeding, light glows, and soft shading. Monte-Carlo based approaches have demonstrated impressive results but are computationally expensive, and faster approaches model either only inter-reflection or only subsurface scattering. In this paper, we present a simple analytic model that combines diffuse inter-reflection and isotropic subsurface scattering. Our approach extends the classical work in radiosity by including a subsurface scattering matrix that operates in conjunction with the traditional form factor matrix. This subsurface scattering matrix can be constructed using analytic, measurement-based or simulation-based models and can capture both homogeneous and heterogeneous translucencies. Using a fast iterative solution to radiosity, we demonstrate scene relighting and dynamically varying object translucencies at near interactive rates.

  12. Hospital factors impact variation in emergency department length of stay more than physician factors.

    PubMed

    Krall, Scott P; Cornelius, Angela P; Addison, J Bruce

    2014-03-01

    To analyze the correlation between the many different emergency department (ED) treatment metric intervals and determine if the metrics directly impacted by the physician correlate to the "door to room" interval in an ED (interval determined by ED bed availability). Our null hypothesis was that the cause of the variation in delay to receiving a room was multifactorial and does not correlate to any one metric interval. We collected daily interval averages from the ED information system, Meditech©. Patient flow metrics were collected on a 24-hour basis. We analyzed the relationship between the time intervals that make up an ED visit and the "arrival to room" interval using simple correlation (Pearson Correlation coefficients). Summary statistics of industry standard metrics were also done by dividing the intervals into 2 groups, based on the average ED length of stay (LOS) from the National Hospital Ambulatory Medical Care Survey: 2008 Emergency Department Summary. Simple correlation analysis showed that the doctor-to-discharge time interval had no correlation to the interval of "door to room (waiting room time)", correlation coefficient (CC) (CC=0.000, p=0.96). "Room to doctor" had a low correlation to "door to room" CC=0.143, while "decision to admitted patients departing the ED time" had a moderate correlation of 0.29 (p <0.001). "New arrivals" (daily patient census) had a strong correlation to longer "door to room" times, 0.657, p<0.001. The "door to discharge" times had a very strong correlation CC=0.804 (p<0.001), to the extended "door to room" time. Physician-dependent intervals had minimal correlation to the variation in arrival to room time. The "door to room" interval was a significant component to the variation in "door to discharge" i.e. LOS. The hospital-influenced "admit decision to hospital bed" i.e. hospital inpatient capacity, interval had a correlation to delayed "door to room" time. The other major factor affecting department bed availability was the "total patients per day." The correlation to the increasing "door to room" time also reflects the effect of availability of ED resources (beds) on the patient evaluation time. The time that it took for a patient to receive a room appeared more dependent on the system resources, for example, beds in the ED, as well as in the hospital, than on the physician.

  13. jasonSWIR Calibration of Spectralon Reflectance Factor

    NASA Technical Reports Server (NTRS)

    Georgiev, Georgi T.; Butler, James J.; Cooksey, Cahterine; Ding, Leibo; Thome, Kurtis J.

    2011-01-01

    Satellite instruments operating in the reflective solar wavelength region require accurate and precise determination of the Bidirectional Reflectance Factor (BRF) of laboratory-based diffusers used in their pre-flight and on-orbit radiometric calibrations. BRF measurements are required throughout the reflected-solar spectrum from the ultraviolet through the shortwave infrared. Spectralon diffusers are commonly used as a reflectance standard for bidirectional and hemispherical geometries. The Diffuser Calibration Laboratory (DCaL) at NASA's Goddard Space Flight Center is a secondary calibration facility with reflectance measurements traceable to those made by the Spectral Tri-function Automated Reference Reflectometer (STARR) facility at the National Institute of Standards and Technology (NIST). For more than two decades, the DCaL has provided numerous NASA projects with BRF data in the ultraviolet (UV), visible (VIS) and the Near infraRed (NIR) spectral regions. Presented in this paper are measurements of BRF from 1475nm to 1625nm obtained using an indium gallium arsenide detector and a tunable coherent light source. The sample was a 2 inch diameter, 99% white Spectralon target. The BRF results are discussed and compared to empirically generated data from a model based on NIST certified values of 6deg directional/hemispherical spectral reflectance factors from 900nm to 2500nm. Employing a new NIST capability for measuring bidirectional reflectance using a cooled, extended InGaAs detector, BRF calibration measurements of the same sample were also made using NIST's STARR from 1475nm to 1625nm at an incident angle of 0deg and at viewing angles of 40deg, 45deg, and 50deg. The total combined uncertainty for BRF in this ShortWave Infrared (SWIR) range is less than 1%. This measurement capability will evolve into a BRF calibration service in SWIR region in support of NASA remote sensing missions. Keywords: BRF, BRDF, Calibration, Spectralon, Reflectance, Remote Sensing.

  14. Synthesis of Al₂Ca Dispersoids by Powder Metallurgy Using a Mg-Al Alloy and CaO Particles.

    PubMed

    Fujita, Junji; Umeda, Junko; Kondoh, Katsuyoshi

    2017-06-28

    The elemental mixture of Mg-6 wt %Al-1 wt %Zn-0.3 wt %Mn (AZ61B) alloy powder and CaO particles was consolidated by an equal-channel angular bulk mechanical alloying (ECABMA) process to form a composite precursor. Subsequently, the precursor was subjected to a heat treatment to synthesize fine Al₂Ca particles via a solid-state reaction between the Mg-Al matrix and CaO additives. Scanning electron microscopy-energy-dispersive spectroscopy (SEM-EDS) and electron probe micro-analysis on the precursor indicated that 4.7-at % Al atoms formed a supersaturated solid solution in the α-Mg matrix. Transmission electron microscopy-EDS and X-ray diffraction analyses on the AZ61B composite precursor with 10-vol % CaO particles obtained by heat treatment confirmed that CaO additives were thermally decomposed in the Mg-Al alloy, and the solid-soluted Ca atoms diffused along the α-Mg grain boundaries. Al atoms also diffused to the grain boundaries because of attraction to the Ca atoms resulting from a strong reactivity between Al and Ca. As a result, needle-like (Mg,Al)₂Ca intermetallics were formed as intermediate precipitates in the initial reaction stage during the heat treatment. Finally, the precipitates were transformed into spherical Al₂Ca particles by the substitution of Al atoms for Mg atoms in (Mg,Al)₂Ca after a long heat treatment.

  15. Current trends in protein crystallization.

    PubMed

    Gavira, José A

    2016-07-15

    Proteins belong to the most complex colloidal system in terms of their physicochemical properties, size and conformational-flexibility. This complexity contributes to their great sensitivity to any external change and dictate the uncertainty of crystallization. The need of 3D models to understand their functionality and interaction mechanisms with other neighbouring (macro)molecules has driven the tremendous effort put into the field of crystallography that has also permeated other fields trying to shed some light into reluctant-to-crystallize proteins. This review is aimed at revising protein crystallization from a regular-laboratory point of view. It is also devoted to highlight the latest developments and achievements to produce, identify and deliver high-quality protein crystals for XFEL, Micro-ED or neutron diffraction. The low likelihood of protein crystallization is rationalized by considering the intrinsic polypeptide nature (folded state, surface charge, etc) followed by a description of the standard crystallization methods (batch, vapour diffusion and counter-diffusion), including high throughput advances. Other methodologies aimed at determining protein features in solution (NMR, SAS, DLS) or to gather structural information from single particles such as Cryo-EM are also discussed. Finally, current approaches showing the convergence of different structural biology techniques and the cross-methodologies adaptation to tackle the most difficult problems, are presented. Current advances in biomacromolecules crystallization, from nano crystals for XFEL and Micro-ED to large crystals for neutron diffraction, are covered with special emphasis in methodologies applicable at laboratory scale. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Development of response models for the Earth Radiation Budget Experiment (ERBE) sensors. Part 2: Analysis of the ERBE integrating sphere ground calibration

    NASA Technical Reports Server (NTRS)

    Halyo, Nesim; Taylor, Deborah B.

    1987-01-01

    An explicit solution of the spectral radiance leaving an arbitrary point on the wall of a spherical cavity with diffuse reflectivity is obtained. The solution is applicable to spheres with an arbitrary number of openings of any size and shape, an arbitrary number of light sources with possible non-diffuse characteristics, a non-uniform sphere wall temperature distribution, non-uniform and non-diffuse sphere wall emissivity and non-uniform but diffuse sphere wall spectral reflectivity. A general measurement equation describing the output of a sensor with a given field of view, angular and spectral response measuring the sphere output is obtained. The results are applied to the Earth Radiation Budget Experiment (ERBE) integrating sphere. The sphere wall radiance uniformity, loading effects and non-uniform wall temperature effects are investigated. It is shown that using appropriate interpretation and processing, a high-accuracy short-wave calibration of the ERBE sensors can be achieved.

  17. Diffused sunlight driven highly synergistic pathway for complete mineralization of organic contaminants using reduced graphene oxide supported photocatalyst.

    PubMed

    Babu, Sundaram Ganesh; Ramalingam Vinoth; Neppolian, Bernaurdshaw; Dionysiou, Dionysios D; Ashokkumar, Muthupandian

    2015-06-30

    Diffused sunlight is found to be an effective light source for the efficient degradation and mineralization of organic pollutant (methyl orange as a probe) by sono-photocatalytic degradation using reduced graphene oxide (rGO) supported CuO-TiO2 photocatalyst. The prepared catalysts are characterized by XRD, XPS, UV-vis DRS, PL, photoelectrochemical, SEM-EDS and TEM. A 10 fold synergy is achieved for the first time by combining sonochemical and photocatalytic degradation under diffused sunlight. rGO loading augments the activity of bare CuO-TiO2 more than two fold. The ability of rGO in storing, transferring, and shuttling electrons at the heterojunction between TiO2 and CuO facilitates the separation of photogenerated electron-hole pairs, as evidenced by the photoluminescence results. The complete mineralization of MO and the by-products within a short span of time is confirmed by TOC analysis. Further, hydroxyl radical mediated degradation under diffused sunlight is confirmed by LC-MS. This system shows similar activity for the degradation of methylene blue and 4-chlorophenol indicating the versatility of the catalyst for the degradation of various pollutants. This investigation is likely to open new possibilities for the development of highly efficient diffused sunlight driven TiO2 based photocatalysts for the complete mineralization of organic contaminants. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Characterizing Intraorbital Optic Nerve Changes on Diffusion Tensor Imaging in Thyroid Eye Disease Before Dysthyroid Optic Neuropathy.

    PubMed

    Lee, Hwa; Lee, Young Hen; Suh, Sang-Il; Jeong, Eun-Kee; Baek, Sehyun; Seo, Hyung Suk

    The aim of this study was to determine whether the optic nerve is affected by thyroid eye disease (TED) before the development of dysthyroid optic neuropathy with diffusion-tensor imaging (DTI). Twenty TED patients and 20 controls were included. The mean, axial, and radial diffusivities and fractional anisotropy (FA) value were measured at the optic nerves in DTI. Extraocular muscle diameters were measured on computed tomography. The diffusivities and FA of the optic nerves were compared between TED and controls and between active and inactive stages of TED. The correlations between these DTI parameters and the clinical features were determined. The mean, axial, and radial diffusivities were lower in TED compared with the controls (P < 0.05). In contrast, FA was higher in TED (P = 0.001). Radial diffusivity was lower in the active stage of TED than the inactive stage (P = 0.035). The FA was higher in the TED group than in the control group (P = 0.021) and was positively correlated with clinical activity score (r = 0.364, P = 0.021), modified NOSPECS score (r = 0.469, P = 0.002), and extraocular muscle thickness (r = 0.325, P = 0.041) in the TED group. Radial diffusivity was negatively correlated with modified NOSPECS score (r = -0.384, P = 0.014), and axial diffusivity was positively correlated with exophthalmos degree (r = 0.363, P = 0.025). The diffusivities and FA reflected changes in the optic nerve before dysthyroid optic neuropathy in TED. The FA, in particular, reflected TED activity and severity.

  19. The Diffuse Interstellar Bands: Contributed papers

    NASA Technical Reports Server (NTRS)

    Tielens, Alexander G. G. M. (Editor)

    1994-01-01

    Drawing a coherent picture of the observational characteristics of the Diffuse Interstellar Bands (DIB's) and the physical and chemical properties of its proposed carriers was the focus of this NASA sponsored conference. Information relating to absoption spectra, diffuse radiation carriers, carbon compounds, stellar composition, and interstellar extinction involving T-Tauri stars, Reflection Nebulae, Red Giants, and accretion discs are discussed from those papers presented at the conference, which are included in this analytic.

  20. Angular intensity and polarization dependence of diffuse transmission through random media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eliyahu, D.; Rosenbluh, M.; Feund, I.

    1993-03-01

    A simple theoretical model involving only a single sample parameter, the depolarization ratio [rho] for linearly polarized normally incident and normally scattered light, is developed to describe the angular intensity and all other polarization-dependent properties of diffuse transmission through multiple-scattering media. Initial experimental results that tend to support the theory are presented. Results for diffuse reflection are also described. 63 refs., 15 figs.

  1. Multi-spectral imaging of oxygen saturation

    NASA Astrophysics Data System (ADS)

    Savelieva, Tatiana A.; Stratonnikov, Aleksander A.; Loschenov, Victor B.

    2008-06-01

    The system of multi-spectral imaging of oxygen saturation is an instrument that can record both spectral and spatial information about a sample. In this project, the spectral imaging technique is used for monitoring of oxygen saturation of hemoglobin in human tissues. This system can be used for monitoring spatial distribution of oxygen saturation in photodynamic therapy, surgery or sports medicine. Diffuse reflectance spectroscopy in the visible range is an effective and extensively used technique for the non-invasive study and characterization of various biological tissues. In this article, a short review of modeling techniques being currently in use for diffuse reflection from semi-infinite turbid media is presented. A simple and practical model for use with a real-time imaging system is proposed. This model is based on linear approximation of the dependence of the diffuse reflectance coefficient on relation between absorbance and reduced scattering coefficient. This dependence was obtained with the Monte Carlo simulation of photon propagation in turbid media. Spectra of the oxygenated and deoxygenated forms of hemoglobin differ mostly in the red area (520 - 600 nm) and have several characteristic points there. Thus four band-pass filters were used for multi-spectral imaging. After having measured the reflectance, the data obtained are used for fitting the concentration of oxygenated and free hemoglobin, and hemoglobin oxygen saturation.

  2. Diffuse-Illumination Systems for Growing Plants

    NASA Technical Reports Server (NTRS)

    May, George; Ryan, Robert

    2010-01-01

    Agriculture in both terrestrial and space-controlled environments relies heavily on artificial illumination for efficient photosynthesis. Plant-growth illumination systems require high photon flux in the spectral range corresponding with plant photosynthetic active radiation (PAR) (400 700 nm), high spatial uniformity to promote uniform growth, and high energy efficiency to minimize electricity usage. The proposed plant-growth system takes advantage of the highly diffuse reflective surfaces on the interior of a sphere, hemisphere, or other nearly enclosed structure that is coated with highly reflective materials. This type of surface and structure uniformly mixes discrete light sources to produce highly uniform illumination. Multiple reflections from within the domelike structures are exploited to obtain diffuse illumination, which promotes the efficient reuse of photons that have not yet been absorbed by plants. The highly reflective surfaces encourage only the plant tissue (placed inside the sphere or enclosure) to absorb the light. Discrete light sources, such as light emitting diodes (LEDs), are typically used because of their high efficiency, wavelength selection, and electronically dimmable properties. The light sources are arranged to minimize shadowing and to improve uniformity. Different wavelengths of LEDs (typically blue, green, and red) are used for photosynthesis. Wavelengths outside the PAR range can be added for plant diagnostics or for growth regulation

  3. Task Inhibition and Response Inhibition in Older vs. Younger Adults: A Diffusion Model Analysis

    PubMed Central

    Schuch, Stefanie

    2016-01-01

    Differences in inhibitory ability between older (64–79 years, N = 24) and younger adults (18–26 years, N = 24) were investigated using a diffusion model analysis. Participants performed a task-switching paradigm that allows assessing n−2 task repetition costs, reflecting inhibitory control on the level of tasks, as well as n−1 response-repetition costs, reflecting inhibitory control on the level of responses. N−2 task repetition costs were of similar size in both age groups. Diffusion model analysis revealed that for both younger and older adults, drift rate parameters were smaller in the inhibition condition relative to the control condition, consistent with the idea that persisting task inhibition slows down response selection. Moreover, there was preliminary evidence for task inhibition effects in threshold separation and non-decision time in the older, but not the younger adults, suggesting that older adults might apply different strategies when dealing with persisting task inhibition. N−1 response-repetition costs in mean RT were larger in older than younger adults, but in mean error rates tended to be larger in younger than older adults. Diffusion-model analysis revealed longer non-decision times in response repetitions than response switches in both age groups, consistent with the idea that motor processes take longer in response repetitions than response switches due to persisting response inhibition of a previously executed response. The data also revealed age-related differences in overall performance: Older adults responded more slowly and more accurately than young adults, which was reflected by a higher threshold separation parameter in diffusion model analysis. Moreover, older adults showed larger non-decision times and higher variability in non-decision time than young adults, possibly reflecting slower and more variable motor processes. In contrast, overall drift rate did not differ between older and younger adults. Taken together, diffusion model analysis revealed differences in overall performance between the age groups, as well as preliminary evidence for age differences in dealing with task inhibition, but no evidence for an inhibitory deficit in older age. PMID:27895599

  4. Preliminary evaluation of optical glucose sensing in red cell concentrations using near-infrared diffuse-reflectance spectroscopy

    NASA Astrophysics Data System (ADS)

    Suzuki, Yusuke; Maruo, Katsuhiko; Zhang, Alice W.; Shimogaki, Kazushige; Ogawa, Hideto; Hirayama, Fumiya

    2012-01-01

    Bacterial contamination of blood products is one of the most frequent infectious complications of transfusion. Since glucose levels in blood supplies decrease as bacteria proliferate, it should be possible to detect the presence of bacterial contamination by measuring the glucose concentrations in the blood components. Hence this study is aimed to serve as a preliminary study for the nondestructive measurement of glucose level in transfusion blood. The glucose concentrations in red blood cell (RBC) samples were predicted using near-infrared diffuse-reflectance spectroscopy in the 1350 to 1850 nm wavelength region. Furthermore, the effects of donor, hematocrit level, and temperature variations among the RBC samples were observed. Results showed that the prediction performance of a dataset which contained samples that differed in all three parameters had a standard error of 29.3 mg/dL. Multiplicative scatter correction (MSC) preprocessing method was also found to be effective in minimizing the variations in scattering patterns created by various sample properties. The results suggest that the diffuse-reflectance spectroscopy may provide another avenue for the detection of bacterial contamination in red cell concentrations (RCC) products.

  5. Analytical model of diffuse reflectance spectrum of skin tissue

    NASA Astrophysics Data System (ADS)

    Lisenko, S. A.; Kugeiko, M. M.; Firago, V. A.; Sobchuk, A. N.

    2014-01-01

    We have derived simple analytical expressions that enable highly accurate calculation of diffusely reflected light signals of skin in the spectral range from 450 to 800 nm at a distance from the region of delivery of exciting radiation. The expressions, taking into account the dependence of the detected signals on the refractive index, transport scattering coefficient, absorption coefficient and anisotropy factor of the medium, have been obtained in the approximation of a two-layer medium model (epidermis and dermis) for the same parameters of light scattering but different absorption coefficients of layers. Numerical experiments on the retrieval of the skin biophysical parameters from the diffuse reflectance spectra simulated by the Monte Carlo method show that commercially available fibre-optic spectrophotometers with a fixed distance between the radiation source and detector can reliably determine the concentration of bilirubin, oxy- and deoxyhaemoglobin in the dermis tissues and the tissue structure parameter characterising the size of its effective scatterers. We present the examples of quantitative analysis of the experimental data, confirming the correctness of estimates of biophysical parameters of skin using the obtained analytical expressions.

  6. [Study on brand traceability of vinegar based on near infrared spectroscopy technology].

    PubMed

    Guan, Xiao; Liu, Jing; Gu, Fang-Qing; Yang, Yong-Jian

    2014-09-01

    In the present paper, 152 vinegar samples with four different brands were chosen as research targets, and their near infrared spectra were collected by diffusion reflection mode and transmission mode, respectively. Furthermore, the brand traceability models for edible vinegar were constructed. The effects of the collection mode and pretreatment methods of spectrum on the precision of traceability models were investigated intensively. The models constructed by PLS1-DA modeling method using spectrum data of 114 training samples were applied to predict 38 test samples, and R2, RMSEC and RMSEP of the model based on transmission mode data were 0.92, 0.113 and 0.127, respectively, with recognition rate of 76.32%, and those based on diffusion reflection mode data were 0.97, 0.102 and 0.119, with recognition rate of 86.84%. The results demonstrated that the near infrared spectrum combined with PLS1-DA can be used to establish the brand traceability models for edible vinegar, and diffuse reflection mode is more beneficial for predictive ability of the model.

  7. Portable laser-induced breakdown spectroscopy/diffuse reflectance hybrid spectrometer for analysis of inorganic pigments

    NASA Astrophysics Data System (ADS)

    Siozos, Panagiotis; Philippidis, Aggelos; Anglos, Demetrios

    2017-11-01

    A novel, portable spectrometer, combining two analytical techniques, laser-induced breakdown spectroscopy (LIBS) and diffuse reflectance spectroscopy, was developed with the aim to provide an enhanced instrumental and methodological approach with regard to the analysis of pigments in objects of cultural heritage. Technical details about the hybrid spectrometer and its operation are presented and examples are given relevant to the analysis of paint materials. Both LIBS and diffuse reflectance spectra in the visible and part of the near infrared, corresponding to several neat mineral pigment samples, were recorded and the complementary information was used to effectively distinguish different types of pigments even if they had similar colour or elemental composition. The spectrometer was also employed in the analysis of different paints on the surface of an ancient pottery sherd demonstrating the capabilities of the proposed hybrid diagnostic approach. Despite its instrumental simplicity and compact size, the spectrometer is capable of supporting analytical campaigns relevant to archaeological, historical or art historical investigations, particularly when quick data acquisition is required in the context of surveys of large numbers of objects and samples.

  8. Retrieving the optical parameters of biological tissues using diffuse reflectance spectroscopy and Fourier series expansions. I. theory and application.

    PubMed

    Muñoz Morales, Aarón A; Vázquez Y Montiel, Sergio

    2012-10-01

    The determination of optical parameters of biological tissues is essential for the application of optical techniques in the diagnosis and treatment of diseases. Diffuse Reflection Spectroscopy is a widely used technique to analyze the optical characteristics of biological tissues. In this paper we show that by using diffuse reflectance spectra and a new mathematical model we can retrieve the optical parameters by applying an adjustment of the data with nonlinear least squares. In our model we represent the spectra using a Fourier series expansion finding mathematical relations between the polynomial coefficients and the optical parameters. In this first paper we use spectra generated by the Monte Carlo Multilayered Technique to simulate the propagation of photons in turbid media. Using these spectra we determine the behavior of Fourier series coefficients when varying the optical parameters of the medium under study. With this procedure we find mathematical relations between Fourier series coefficients and optical parameters. Finally, the results show that our method can retrieve the optical parameters of biological tissues with accuracy that is adequate for medical applications.

  9. [Study on predicting sugar content and valid acidity of apples by near infrared diffuse reflectance technique].

    PubMed

    Liu, Yan-de; Ying, Yi-bin; Fu, Xia-ping

    2005-11-01

    The nondestructive method for quantifying sugar content (SC) and available acid (VA) of intact apples using diffuse near infrared reflectance and optical fiber sensing techniques were explored in the present research. The standard sample sets and prediction models were established by partial least squares analysis (PLS). A total of 120 Shandong Fuji apples were tested in the wave number of 12,500 - 4000 cm(-1) using Fourier transform near infrared spectroscopy. The results of the research indicated that the nondestructive quantification of SC and VA, gave a high correlation coefficient 0.970 and 0.906, a low root mean square error of prediction (RMSEP) 0.272 and 0.056 2, a low root mean square error of calibration (RMSEC) 0.261 and 0.0677, and a small difference between RMSEP and RMSEC 0.011 a nd 0.0115. It was suggested that the diffuse nearinfrared reflectance technique be feasible for nondestructive determination of apple sugar content in the wave number range of 10,341 - 5461 cm(-1) and for available acid in the wave number range of 10,341 - 3818 cm(-1).

  10. Recovering the superficial microvascular pattern via diffuse reflection imaging: phantom validation.

    PubMed

    Chen, Chen; Florian, Klämpfl; Rajesh, Kanawade; Max, Riemann; Christian, Knipfer; Florian, Stelzle; Michael, Schmidt

    2015-09-30

    Diffuse reflection imaging could potentially be used to recover the superficial microvasculature under cutaneous tissue and the associated blood oxygenation status with a modified imaging resolution. The aim of this work is to deliver a new approach of local off-axis scanning diffuse reflection imaging, with the revisit of the modified Beer-Lambert Law (MBLL). To validate this, the system is used to recover the micron-scale subsurface vessel structure interiorly embedded in a skin equivalent tissue phantom. This vessel structure is perfused with oxygenated meta-hemoglobin solution. Our preliminary results confirm that the thin vessel structure can be mapped into a 2-D planar image. The distributions of oxygenated hemoglobin concentration ([Formula: see text]) and deoxygenated hemoglobin concentration ([Formula: see text]) can be co-registerated through the MBLL upon the CW spectroscopy, the scattering issue is addressed in the reformed MBLL. The recovered pattern matches to the estimation from the simultaneous optical coherence tomography studies. With further modification, this system may serve as the first prototype to investigate the superficial microvasculature in the expotential skin cancer loci, or a micro-lesion of vascular dermatosis.

  11. Parental responses to child experiences of trauma following presentation at emergency departments: a qualitative study

    PubMed Central

    Williamson, Victoria; Creswell, Cathy; Butler, Ian; Christie, Hope

    2016-01-01

    Objective Parents are often children's main source of support following fear-inducing traumatic events, yet little is known about how parents provide that support. The aim of this study was to examine parents' experiences of supporting their child following child trauma exposure and presentation at an emergency department (ED). Design Semistructured qualitative interviews analysed using thematic analysis. Setting The setting for this study was two National Health Service EDs in England. Participants 20 parents whose child experienced a traumatic event and attended an ED between August 2014 and October 2015. Results Parents were sensitive to their child's distress and offered reassurance and support for their child to resume normal activities. However, parental beliefs often inhibited children's reinstatement of pretrauma routines. Support often focused on preventing future illness or injury, reflective of parents' concerns for their child's physical well-being. In a minority of parents, appraisals of problematic care from EDs contributed to parents' anxiety and perceptions of their child as vulnerable post-trauma. Forgetting the trauma and avoidance of discussion were encouraged as coping strategies to prevent further distress. Parents highlighted their need for further guidance and support regarding their child's physical and emotional recovery. Conclusions This study provides insight into the experiences of and challenges faced by parents in supporting their child following trauma exposure. Perceptions of their child's physical vulnerability and treatment influenced parents' responses and the supportive strategies employed. These findings may enable clinicians to generate meaningful advice for parents following child attendance at EDs post-trauma. PMID:27821599

  12. Characterisation of heavy metal-bearing phases in stream sediments of the Meža River Valley, Slovenia, by means of SEM/EDS analysis

    NASA Astrophysics Data System (ADS)

    Miler, M.; Gosar, M.

    2010-02-01

    Stream sediment reflects the rock structure of the catchment area, its geochemical characteristics and possible recent contamination upstream of the sampling point and thus, it is most frequently used in geochemical researches of heavy metal pollution. Stream sediment samples were collected along the Meža River and its tributaries and the Drava River, located in the NNE part of Slovenia. Previous geochemical studies have shown that these sediments are heavily polluted with heavy metals as a consequence of past mining of Pb-Zn ore and steelworks activities. Conventional geochemical analyses (ICP-MS, AAS, etc.) provided limited information on mineralogy, morphology and sources of heavy metal-bearing phases therefore SEM/EDS was utilized. Several problems were confronted with during EDS analysis, which are related to identification and quantification of light elements, identification of elements due to peak overlaps and quantification of spectra from unpolished samples. These problems were successfully dealt with. SEM/EDS enabled successful identification of heavy metal-bearing phases in stream sediments. Ore mineral phases, such as cerussite, sphalerite, smithsonite and galena, different heavy metal-bearing Fe-alloys, Fe-oxides and spherical particles and common rock-forming and accessory mineral phases, such as barite, rutile, ilmenite, zircon and monazite, were identified using solely SEM/EDS. These results were used for subsequent geochemical interpretation and source apportionment of heavy metals, according to associations of different heavy metal-bearing phases. Heavy metal-bearing phases were arranged by their source and genesis into three groups, denoted as geogenic/technogenic, technogenic and geogenic.

  13. Treatment of Acute Abnormal Uterine Bleeding in Adolescents: What Are Providers Doing in Various Specialties?

    PubMed

    Huguelet, Patricia S; Buyers, Eliza M; Lange-Liss, Jill H; Scott, Stephen M

    2016-06-01

    The purpose of this study was to assess whether variability exists in the management of acute abnormal uterine bleeding (AUB) in adolescents between pediatric Emergency Department (ED) physicians, pediatric gynecologists, and adolescent medicine specialists. Retrospective chart review. Tertiary care medical center ED. We included girls aged 9-22 years who presented from July 2008 to June 2014 with the complaint of acute AUB. Patients were identified using the International Classification of Diseases, ninth revision codes for heavy menstrual bleeding, AUB, and irregular menses. Exclusion criteria included pregnancy and current use of hormonal therapy. One hundred fifty patients were included. Among those evaluated, 61% (n = 92) were prescribed hormonal medication to stop their bleeding by providers from the ED, Adolescent Medicine, or Pediatric Gynecology. ED physicians prescribed mostly single-dose and multidose taper combined oral contraceptive pills (85%; n = 24), compared with Adolescent Medicine (54%, n = 7), and Gynecology (28%, n = 13). Pediatric gynecologists were more likely than ED physicians to treat patients with norethindrone acetate, either alone or in combination with a single dose combined oral contraceptive pill (61%, n = 33 vs 7%, n = 2; P < .001). Variations in treatment strategies for adolescents who present with acute AUB exist among pediatric specialties, which reflects a lack of standardized care for adolescents. Prospective evaluation of the shortest interval to cessation of bleeding, side effects, and patient satisfaction are valuable next steps. Copyright © 2015 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  14. The moderating role of cognitive control deficits in the link from emotional dissonance to burnout symptoms and absenteeism.

    PubMed

    Diestel, Stefan; Schmidt, Klaus-Helmut

    2011-07-01

    The present study examines whether cognitive control deficits (CCDs) as a personal vulnerability factor amplify the relationship between emotional dissonance (ED; perceived discrepancy between felt and expressed emotions) and burnout symptoms (emotional exhaustion and depersonalization) as well as absenteeism. CCDs refer to daily failures and impairments of attention regulation, impulse control, and memory. The prediction of the moderator effect of CCDs draws on the argument that portraying emotions which are not genuinely felt is a form of self-regulation taxing and depleting a limited resource capacity. Interindividual differences in the resource capacity are reflected by the measure of CCDs. Drawing on two German samples (one cross-sectional and one longitudinal sample; NTOTAL = 645) of service employees, the present study analyzed interactive effects of ED and CCDs on exhaustion, depersonalization, and two indicators of absenteeism. As was hypothesized, latent moderated structural equation modeling revealed that the adverse impacts of ED on both burnout symptoms and absence behavior were amplified as a function of CCDs. Theoretical and practical implications of the present results will be discussed.

  15. Discussing a sensitive topic: Nurse practitioners' and physician assistants' communication strategies in managing patients with erectile dysfunction.

    PubMed

    Green, Roger; Kodish, Slavica

    2009-12-01

    To examine strategies used by nurse practitioners (NPs) and physician assistants (PAs) when discussing the sensitive topic of erectile dysfunction (ED) with patients. A total of 456 NPs and PAs combined responded to a 22-item online survey posted on NP and PA association websites. Four derived categories reflect communication strategies that NPs and PAs applied when addressing ED: initiating the topic directly, initiating the topic with an introduction, initiating the topic when there is a high risk factor, and allowing the patient to bring up the topic. There was also interest in continuing education on the topic of ED and a perceived need for greater emphasis on developing communication strategies within the patient-provider relationship. There is no one best way to address the topic and different situations may require an approach best suited to the specifics of the situation. Therefore, no single "best practice" of discussing sensitive topics can be identified. Critical thinking skills and the ability to comprehend the totality of the situation are likely to be of higher importance.

  16. Camouflage Visualization

    DTIC Science & Technology

    1992-04-07

    reflected light seen by the viewer does not depend on the viewer’s position. Such surfaces are dull or matte and the luminance of the diffuse reflected light...vegetation and reflect only the skylight . Generally, the reflectance of the ambient light is approximately represented as a global value, constant over all the...allowing the ambient contribution provided by skylight to vary with the orientation of the surface relative to zenith. This approximation takes into

  17. Multi-Scale Modeling and the Eddy-Diffusivity/Mass-Flux (EDMF) Parameterization

    NASA Astrophysics Data System (ADS)

    Teixeira, J.

    2015-12-01

    Turbulence and convection play a fundamental role in many key weather and climate science topics. Unfortunately, current atmospheric models cannot explicitly resolve most turbulent and convective flow. Because of this fact, turbulence and convection in the atmosphere has to be parameterized - i.e. equations describing the dynamical evolution of the statistical properties of turbulence and convection motions have to be devised. Recently a variety of different models have been developed that attempt at simulating the atmosphere using variable resolution. A key problem however is that parameterizations are in general not explicitly aware of the resolution - the scale awareness problem. In this context, we will present and discuss a specific approach, the Eddy-Diffusivity/Mass-Flux (EDMF) parameterization, that not only is in itself a multi-scale parameterization but it is also particularly well suited to deal with the scale-awareness problems that plague current variable-resolution models. It does so by representing small-scale turbulence using a classic Eddy-Diffusivity (ED) method, and the larger-scale (boundary layer and tropospheric-scale) eddies as a variety of plumes using the Mass-Flux (MF) concept.

  18. Role of codeposited impurities during growth. II. Dependence of morphology on binding and barrier energies

    NASA Astrophysics Data System (ADS)

    Sathiyanarayanan, Rajesh; Hamouda, Ajmi Bh.; Pimpinelli, A.; Einstein, T. L.

    2011-01-01

    In an accompanying article we showed that surface morphologies obtained through codeposition of a small quantity (2%) of impurities with Cu during growth (step-flow mode, θ = 40 ML) significantly depends on the lateral nearest-neighbor binding energy (ENN) to Cu adatom and the diffusion barrier (Ed) of the impurity atom on Cu(0 0 1). Based on these two energy parameters, ENN and Ed, we classify impurity atoms into four sets. We study island nucleation and growth in the presence of codeposited impurities from different sets in the submonolayer (θ⩽ 0.7 ML) regime. Similar to growth in the step-flow mode, we find different nucleation and growth behavior for impurities from different sets. We characterize these differences through variations of the number of islands (Ni) and the average island size with coverage (θ). Further, we compute the critical nucleus size (i) for all of these cases from the distribution of capture-zone areas using the generalized Wigner distribution.

  19. Tract-Based Spatial Statistics in Preterm-Born Neonates Predicts Cognitive and Motor Outcomes at 18 Months.

    PubMed

    Duerden, E G; Foong, J; Chau, V; Branson, H; Poskitt, K J; Grunau, R E; Synnes, A; Zwicker, J G; Miller, S P

    2015-08-01

    Adverse neurodevelopmental outcome is common in children born preterm. Early sensitive predictors of neurodevelopmental outcome such as MR imaging are needed. Tract-based spatial statistics, a diffusion MR imaging analysis method, performed at term-equivalent age (40 weeks) is a promising predictor of neurodevelopmental outcomes in children born very preterm. We sought to determine the association of tract-based spatial statistics findings before term-equivalent age with neurodevelopmental outcome at 18-months corrected age. Of 180 neonates (born at 24-32-weeks' gestation) enrolled, 153 had DTI acquired early at 32 weeks' postmenstrual age and 105 had DTI acquired later at 39.6 weeks' postmenstrual age. Voxelwise statistics were calculated by performing tract-based spatial statistics on DTI that was aligned to age-appropriate templates. At 18-month corrected age, 166 neonates underwent neurodevelopmental assessment by using the Bayley Scales of Infant Development, 3rd ed, and the Peabody Developmental Motor Scales, 2nd ed. Tract-based spatial statistics analysis applied to early-acquired scans (postmenstrual age of 30-33 weeks) indicated a limited significant positive association between motor skills and axial diffusivity and radial diffusivity values in the corpus callosum, internal and external/extreme capsules, and midbrain (P < .05, corrected). In contrast, for term scans (postmenstrual age of 37-41 weeks), tract-based spatial statistics analysis showed a significant relationship between both motor and cognitive scores with fractional anisotropy in the corpus callosum and corticospinal tracts (P < .05, corrected). Tract-based spatial statistics in a limited subset of neonates (n = 22) scanned at <30 weeks did not significantly predict neurodevelopmental outcomes. The strength of the association between fractional anisotropy values and neurodevelopmental outcome scores increased from early-to-late-acquired scans in preterm-born neonates, consistent with brain dysmaturation in this population. © 2015 by American Journal of Neuroradiology.

  20. What's Hot, What's Not: 2012

    ERIC Educational Resources Information Center

    Raths, David

    2012-01-01

    Like the Roman god Janus, whose twin faces look both forward and back, "Campus Technology" ("CT") is using the new year as an opportunity to reflect on some of the biggest IT trends and issues of 2011 and predict their fate in 2012. In the turbulent world of higher ed IT, this is no easy task--yesterday's news can easily become tomorrow's snooze.…

  1. Using Metaphoric Body-Mapping to Encourage Reflection on the Developing Identity of Pre-Service Teachers

    ERIC Educational Resources Information Center

    Botha, Carolina S.

    2017-01-01

    This article explores the contribution that a teaching strategy, such as metaphoric body-mapping, can make towards the discourse on the development of professional teacher identity. Second-year students in a Life Orientation methodology module in a B.Ed programme were offered the opportunity to validate their local knowledge and make new meaning…

  2. Introduction to "Multicultural Voices: Peer Tutoring and Critical Reflection in the Writing Center"

    ERIC Educational Resources Information Center

    Grimm, Nancy Maloney

    2010-01-01

    In 1991 when Diana George, Ed Lotto, and the author were publishing their first issue as "WCJ" editors, this multivoiced essay struck her as a prime example of their editorial belief that writing centers could be "agents of change in the academy." As Gail Okawa and Tom Fox observe, "Most universities are inhospitable to more democratic definitions…

  3. A Teacher's Guide to Including Students with Disabilities in General Physical Education, Third Edition

    ERIC Educational Resources Information Center

    Block, Martin E.

    2007-01-01

    This book, provides a comprehensive guide to making phys. ed. inclusion work for students of all ages. In this new edition of the trusted bestseller, renowned expert Martin E. Block and a select group of highly respected contributors provide: (1) new information reflecting all the latest updates to IDEA, other disability-related legislation, and…

  4. Autonomy and Submissiveness as Cognitive and Cultural Factors Influencing Eating Disorders in Italy and Sweden: An Exploratory Study.

    PubMed

    Sassaroli, Sandra; Veronese, Guido; Nevonen, Lauri; Fiore, Francesca; Centorame, Franceso; Favaretto, Ettore; Ruggiero, Giovanni Maria

    2015-05-01

    The aim of this exploratory study was to investigate the correlation between cultural and psychological factors in relation to predicting eating disorders in two different non-clinical Italian (n = 61) and Swedish (n = 31) female populations, thought to have different cultures and lifestyles. The Swedish sample would reflect an emancipated model of women pursuing autonomy and freedom but also an ideal of thinness, while the Italian sample would reflect a difficult transition from traditional submissiveness to modern autonomy. Both groups completed self-report instruments assessing cultural values (e.g., collectivism and individualism) and features of eating disorders (e.g., drive for thinness, bulimia, body dissatisfaction, self-esteem, parental criticism and perfectionism). Swedish women were found to display higher levels of bulimia, perfectionism, and individualism than Italian women, while regression analysis showed that in the Italian sample high levels of collectivism were correlated with measures of EDs. The results support the hypothesis that EDs are linked with both modern values of autonomy, independence and emancipation, and situations of cultural transition in which women are simultaneously exposed to traditional models of submission and opportunities for emancipation and autonomy.

  5. Autonomy and Submissiveness as Cognitive and Cultural Factors Influencing Eating Disorders in Italy and Sweden: An Exploratory Study

    PubMed Central

    Sassaroli, Sandra; Veronese, Guido; Nevonen, Lauri; Fiore, Francesca; Centorame, Franceso; Favaretto, Ettore; Ruggiero, Giovanni Maria

    2015-01-01

    The aim of this exploratory study was to investigate the correlation between cultural and psychological factors in relation to predicting eating disorders in two different non-clinical Italian (n = 61) and Swedish (n = 31) female populations, thought to have different cultures and lifestyles. The Swedish sample would reflect an emancipated model of women pursuing autonomy and freedom but also an ideal of thinness, while the Italian sample would reflect a difficult transition from traditional submissiveness to modern autonomy. Both groups completed self-report instruments assessing cultural values (e.g., collectivism and individualism) and features of eating disorders (e.g., drive for thinness, bulimia, body dissatisfaction, self-esteem, parental criticism and perfectionism). Swedish women were found to display higher levels of bulimia, perfectionism, and individualism than Italian women, while regression analysis showed that in the Italian sample high levels of collectivism were correlated with measures of EDs. The results support the hypothesis that EDs are linked with both modern values of autonomy, independence and emancipation, and situations of cultural transition in which women are simultaneously exposed to traditional models of submission and opportunities for emancipation and autonomy. PMID:27247654

  6. Fourier Transform Infrared Spectroscopy Part III. Applications.

    ERIC Educational Resources Information Center

    Perkins, W. D.

    1987-01-01

    Discusses the use of the FT-IR spectrometer in analyses that were previously avoided. Examines some of the applications of this spectroscopy with aqueous solutions, circular internal reflection, samples with low transmission, diffuse reflectance, infrared emission, and the infrared microscope. (TW)

  7. Effect of sample thickness on the extracted near-infrared bulk optical properties of Bacillus subtilis in liquid culture.

    PubMed

    Dzhongova, Elitsa; Harwood, Colin R; Thennadil, Suresh N

    2011-11-01

    In order to determine the bulk optical properties of a Bacillus subtilis culture during growth phase we investigated the effect of sample thickness on measurements taken with different measurement configurations, namely total diffuse reflectance and total diffuse transmittance. The bulk optical properties were extracted by inverting the measurements using the radiative transfer theory. While the relationship between reflectance and biomass changes with sample thickness and the intensity (absorbance) levels vary significantly for both reflectance and transmittance measurements, the extracted optical properties show consistent behavior in terms of both the relationship with biomass and magnitude. This observation indicates the potential of bulk optical properties for building models that could be more easily transferable compared to those built using raw measurements.

  8. Radiant exchange in partially specular architectural environments

    NASA Astrophysics Data System (ADS)

    Beamer, C. Walter; Muehleisen, Ralph T.

    2003-10-01

    The radiant exchange method, also known as radiosity, was originally developed for thermal radiative heat transfer applications. Later it was used to model architectural lighting systems, and more recently it has been extended to model acoustic systems. While there are subtle differences in these applications, the basic method is based on solving a system of energy balance equations, and it is best applied to spaces with mainly diffuse reflecting surfaces. The obvious drawback to this method is that it is based around the assumption that all surfaces in the system are diffuse reflectors. Because almost all architectural systems have at least some partially specular reflecting surfaces in the system it is important to extend the radiant exchange method to deal with this type of surface reflection. [Work supported by NSF.

  9. Solar-diffuser panel and ratioing radiometer approach to satellite sensor on-board calibration

    NASA Technical Reports Server (NTRS)

    Slater, Philip N.; Palmer, James M.

    1991-01-01

    The use of a solar-diffuser panel is a desirable approach to the on-board absolute radiometric calibration of satellite multispectral sensors used for earth observation in the solar reflective spectral range. It provides a full aperture, full field, end-to-end calibration near the top of the sensor's dynamic range and across its entire spectral response range. A serious drawback is that the panel's reflectance, and the response of any simple detector used to monitor its reflectance may change with time. This paper briefly reviews some preflight and on-board methods for absolute calibration and introduces the ratioing-radiometer concept in which the radiance of the panel is ratioed with respect to the solar irradiance at the time the multispectral sensor is viewing the panel in its calibration mode.

  10. Upstream gyrophase bunched ions - A mechanism for creation at the bow shock and the growth of velocity space structure through gyrophase mixing

    NASA Technical Reports Server (NTRS)

    Gurgiolo, C.; Parks, G. K.; Mauk, G. H.

    1983-01-01

    The conditions necessary for the production of gyrophase bunched ions at the bow shock are developed. The conditions are applied to the reflection mechanism presented by Paschmann et al. (1980), showing that when in their model a portion of the incident parallel velocity is converted into reflected perpendicular velocity, the reflected particles are gyrophase bunched. The growth of velocity space structure in the gyrophase bunched distribution through gyrophase mixing is also explored. The structure is found to be similar to that reported in diffuse and dispersed ion events. This together with the close correlation of the observation of gyrophase bunched ions with diffuse and dispersed ions has led us to speculate that these two populations may be closely related.

  11. Directional Degradation of Spectralon Diffuser Under Ionizing Radiation for Calibration of Space-Based Sensors

    NASA Technical Reports Server (NTRS)

    Georgiev, G. T.; Butler, J. J.; Kowalewski, M. G.; Ding, L.

    2012-01-01

    Assessment of the effect of Vacuum Ultra Violet (VUV) irradiation on the Bidirectional Reflectance Distribution Function (BRDF) of Spectralon is presented in this paper. The sample was a 99% white Spectralon calibration standard irradiated with VUV source positioned at 60o off the irradiation direction for a total of 20 hours. The BRDF before and after VUV irradiation was measured and compared at number of wavelengths in the UV, VIS and IR. Non-isotropic directional degradation of Spectralon diffuser under ionizing radiation was detected at different BRDF measurement geometries primarily at UV spectral range. The 8o directional/hemispherical reflectance of the same sample was also measured and compared from 200nm to 2500nm. Index Terms BRDF, Reflectance, Multiangular, Spectralon, Remote Sensing

  12. Positional dependence of the SNPP VIIRS SD BRDF degradation factor

    NASA Astrophysics Data System (ADS)

    Lei, Ning; Chen, Xuexia; Chang, Tiejun; Xiong, Xiaoxiong

    2017-09-01

    The Visible Infrared Imaging Radiometer Suite (VIIRS) aboard the Suomi National Polar-orbiting Partnership (SNPP) satellite is a passive scanning radiometer and an imager. The VIIRS regularly performs on-orbit radiometric calibration of its reflective solar bands (RSBs) through observing an onboard sunlit solar diffuser (SD). The reflectance of the SD changes over time and the change is denoted as the SD bidirectional reflectance distribution function degradation factor. The degradation factor, measured by an onboard solar diffuser stability monitor, has been shown to be both incident sunlight and outgoing direction dependent. In this Proceeding, we investigate the factor's dependence on SD position. We develop a model to relate the SD degradation factor with the amount of solar exposure. We use Earth measurements to evaluate the effectiveness of the model.

  13. Jigsaw puzzle metasurface for multiple functions: polarization conversion, anomalous reflection and diffusion.

    PubMed

    Zhao, Yi; Cao, Xiangyu; Gao, Jun; Liu, Xiao; Li, Sijia

    2016-05-16

    We demonstrate a simple reconfigurable metasurface with multiple functions. Anisotropic tiles are investigated and manufactured as fundamental elements. Then, the tiles are combined in a certain sequence to construct a metasurface. Each of the tiles can be adjusted independently which is like a jigsaw puzzle and the whole metasurface can achieve diverse functions by different layouts. For demonstration purposes, we realize polarization conversion, anomalous reflection and diffusion by a jigsaw puzzle metasurface with 6 × 6 pieces of anisotropic tile. Simulated and measured results prove that our method offers a simple and effective strategy for metasurface design.

  14. Milne problem for non-absorbing medium with extremely anisotropic scattering kernel in the case of specular and diffuse reflecting boundaries

    NASA Astrophysics Data System (ADS)

    Güleçyüz, M. Ç.; Şenyiğit, M.; Ersoy, A.

    2018-01-01

    The Milne problem is studied in one speed neutron transport theory using the linearly anisotropic scattering kernel which combines forward and backward scatterings (extremely anisotropic scattering) for a non-absorbing medium with specular and diffuse reflection boundary conditions. In order to calculate the extrapolated endpoint for the Milne problem, Legendre polynomial approximation (PN method) is applied and numerical results are tabulated for selected cases as a function of different degrees of anisotropic scattering. Finally, some results are discussed and compared with the existing results in literature.

  15. Critical comparison of diffuse reflectance spectroscopy and colorimetry as dermatological diagnostic tools for acanthosis nigricans: a chemometric approach

    PubMed Central

    Devpura, Suneetha; Pattamadilok, Bensachee; Syed, Zain U.; Vemulapalli, Pranita; Henderson, Marsha; Rehse, Steven J.; Hamzavi, Iltefat; Lim, Henry W.; Naik, Ratna

    2011-01-01

    Quantification of skin changes due to acanthosis nigricans (AN), a disorder common among insulin-resistant diabetic and obese individuals, was investigated using two optical techniques: diffuse reflectance spectroscopy (DRS) and colorimetry. Measurements were obtained from AN lesions on the neck and two control sites of eight AN patients. A principal component/discriminant function analysis successfully differentiated between AN lesion and normal skin with 87.7% sensitivity and 94.8% specificity in DRS measurements and 97.2% sensitivity and 96.4% specificity in colorimetry measurements. PMID:21698027

  16. Diagnostics of breast cancer by analysis of spectra diffuse reflections

    NASA Astrophysics Data System (ADS)

    Kuzmina, Natalya V.; Plaksin, Fedor G.; Polovnikov, Eugeny S.

    2001-05-01

    The work is dedicated to problems of diagnostic oncologic diseases by a spectroscopic-optical method and is prolongation of long-term examinations held earlier by Vovk S.M, Naumov S.A. and Pushkarev S.V. The actual spectra of a diffuse reflection removed in vivo and in vitro are given, is angry- and good-quality neoplasms, healthy tissue and blood of breast and other organs. Problems of a clinical oncology are in a center of attention in medicine because the cases of disease malignant swellings increase, which is stipulated by an irregularity of present methods of diagnostic.

  17. Sound propagation in urban areas: a periodic disposition of buildings.

    PubMed

    Picaut, J; Hardy, J; Simon, L

    1999-10-01

    A numerical simulation of background noise propagation is performed for a network of hexagonal buildings. The obtained results suggest that the prediction of background noise in urban spaces is possible by means of a modified diffusion equation using two parameters: the diffusion coefficient that expresses the spreading out of noise resulting from diffuse scattering and multiple reflections by buildings, and an attenuation term accounting for the wall absorption, atmospheric attenuation, and absorption by the open top. The dependence of the diffusion coefficient with geometrical shapes and the diffusive nature of the buildings are investigated in the case of a periodic disposition of hexagonal buildings.

  18. Anomalous diffusion of poly(ethylene oxide) in agarose gels.

    PubMed

    Brenner, Tom; Matsukawa, Shingo

    2016-11-01

    We report on the effect of probe size and diffusion time of poly(ethylene) oxide in agarose gels. Time-dependence of the diffusion coefficient, reflecting anomalous diffusion, was observed for poly(ethylene) oxide chains with hydrodynamic radii exceeding about 20nm at an agarose concentration of 2%. The main conclusion is that the pore distribution includes pores that are only several nm across, in agreement with scattering reports in the literature. Interpretation of the diffusion coefficient dependence on the probe size based on a model of entangled rigid rods yielded a rod length of 72nm. Copyright © 2016. Published by Elsevier B.V.

  19. Clinical applications and characteristics of apparent diffusion coefficient maps for the brain of two dogs.

    PubMed

    Kim, Boeun; Yi, Kangjae; Jung, Sunyoung; Ji, Seoyeon; Choi, Mincheol; Yoon, Junghee

    2014-01-01

    Diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) mapping are functional magnetic resonance imaging techniques for detecting water diffusion. DWI and the ADC map were performed for intracranial lesions in two dogs. In necrotizing leukoencephalitis, cavitated lesions contained a hypointense center with a hyperintense periphery on DWI, and hyperintense signals on the ADC maps. In metastatic sarcoma, masses including a necrotic region were hypointense with DWI, and hyperintense on the ADC map with hyperintense perilesional edema on DWI and ADC map. Since DWI and ADC data reflect the altered water diffusion, they can provide additional information at the molecular level.

  20. Optimization of the Inverse Algorithm for Estimating the Optical Properties of Biological Materials Using Spatially-resolved Diffuse Reflectance Technique

    USDA-ARS?s Scientific Manuscript database

    Determination of the optical properties from intact biological materials based on diffusion approximation theory is a complicated inverse problem, and it requires proper implementation of inverse algorithm, instrumentation, and experiment. This work was aimed at optimizing the procedure of estimatin...

Top